WorldWideScience

Sample records for radiography equipment safety

  1. Radiation Safety in Industrial Radiography. Specific Safety Guide

    International Nuclear Information System (INIS)

    2011-01-01

    This Safety Guide provides recommendations for ensuring radiation safety in industrial radiography used in non-destructive testing. This includes industrial radiography work that utilizes X ray and gamma sources, both in shielded facilities that have effective engineering controls and in outside shielded facilities using mobile sources. Contents: 1. Introduction; 2. Duties and responsibilities; 3. Safety assessment; 4. Radiation protection programme; 5. Training and qualification; 6. Individual monitoring of workers; 7. Workplace monitoring; 8. Control of radioactive sources; 9. Safety of industrial radiography sources and exposure devices; 10. Radiography in shielded enclosures; 11. Site radiography; 12. Transport of radioactive sources; 13. Emergency preparedness and response; Appendix: IAEA categorization of radioactive sources; Annex I: Example safety assessment; Annex II: Overview of industrial radiography sources and equipment; Annex III: Examples of accidents in industrial radiography.

  2. Radiation Safety in Industrial Radiography. Specific Safety Guide (French Edition); Surete radiologique en radiographie industrielle

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-05-15

    This Safety Guide provides recommendations for ensuring radiation safety in industrial radiography used in non-destructive testing. This includes industrial radiography work that utilizes X ray and gamma sources, both in Horizontal-Ellipsis shielded facilities that have effective engineering controls and in outside shielded facilities using mobile sources. Contents: 1. Introduction; 2. Duties and responsibilities; 3. Safety assessment; 4. Radiation protection programme; 5. Training and qualification; 6. Individual monitoring of workers; 7. Workplace monitoring; 8. Control of radioactive sources; 9. Safety of industrial radiography sources and exposure devices; 10. Radiography in shielded enclosures; 11. Site radiography; 12. Transport of radioactive sources; 13. Emergency preparedness and response; Appendix: IAEA categorization of radioactive sources; Annex I: Example safety assessment; Annex II: Overview of industrial radiography sources and equipment; Annex III: Examples of accidents in industrial radiography.

  3. Radiation Safety in Industrial Radiography. Specific Safety Guide (Spanish Edition)

    International Nuclear Information System (INIS)

    2013-01-01

    This Safety Guide provides recommendations for ensuring radiation safety in industrial radiography used in non-destructive testing. This includes industrial radiography work that utilizes X ray and gamma sources, both in shielded facilities that have effective engineering controls and in outside shielded facilities using mobile sources. Contents: 1. Introduction; 2. Duties and responsibilities; 3. Safety assessment; 4. Radiation protection programme; 5. Training and qualification; 6. Individual monitoring of workers; 7. Workplace monitoring; 8. Control of radioactive sources; 9. Safety of industrial radiography sources and exposure devices; 10. Radiography in shielded enclosures; 11. Site radiography; 12. Transport of radioactive sources; 13. Emergency preparedness and response; Appendix: IAEA categorization of radioactive sources; Annex I: Example safety assessment; Annex II: Overview of industrial radiography sources and equipment; Annex III: Examples of accidents in industrial radiography

  4. Radiation Safety in Industrial Radiography. Specific Safety Guide (French Edition)

    International Nuclear Information System (INIS)

    2013-01-01

    This Safety Guide provides recommendations for ensuring radiation safety in industrial radiography used in non-destructive testing. This includes industrial radiography work that utilizes X ray and gamma sources, both in … shielded facilities that have effective engineering controls and in outside shielded facilities using mobile sources. Contents: 1. Introduction; 2. Duties and responsibilities; 3. Safety assessment; 4. Radiation protection programme; 5. Training and qualification; 6. Individual monitoring of workers; 7. Workplace monitoring; 8. Control of radioactive sources; 9. Safety of industrial radiography sources and exposure devices; 10. Radiography in shielded enclosures; 11. Site radiography; 12. Transport of radioactive sources; 13. Emergency preparedness and response; Appendix: IAEA categorization of radioactive sources; Annex I: Example safety assessment; Annex II: Overview of industrial radiography sources and equipment; Annex III: Examples of accidents in industrial radiography

  5. Radiation Safety in Industrial Radiography. Specific Safety Guide (Arabic Edition)

    International Nuclear Information System (INIS)

    2012-01-01

    This Safety Guide provides recommendations for ensuring radiation safety in industrial radiography used in non-destructive testing. This includes industrial radiography work that utilizes X ray and gamma sources, both in shielded facilities that have effective engineering controls and outside shielded facilities using mobile sources. Contents: 1. Introduction; 2. Duties and responsibilities; 3. Safety assessment; 4. Radiation protection programme; 5. Training and qualification; 6. Individual monitoring of workers; 7. Workplace monitoring; 8. Control of radioactive sources; 9. Safety of industrial radiography sources and exposure devices; 10. Radiography in shielded enclosures; 11. Site radiography; 12. Transport of radioactive sources; 13. Emergency preparedness and response; Appendix: IAEA categorization of radioactive sources; Annex I: Example safety assessment; Annex II: Overview of industrial radiography sources and equipment; Annex III: Examples of accidents in industrial radiography.

  6. The tendency of medical electrical equipment - IEC 60601-2-54: Particular requirements for the basic safety and essential performance of x-ray equipment for radiography and radioscopy

    International Nuclear Information System (INIS)

    Roh, Young Hoon; Kim, Jung Min

    2015-01-01

    Medical electrical equipment - Part 1: General requirement for basic safety and essential performance of MFDS was revised as 3th edition and Medical electrical equipment Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment will be expected to be announced as notification. Therefore this technical report was written to introduce provision of the particular requirements, replacement, addition, amendment. The purpose of this particular requirements is to secure requirements for basic safety and essential performance of X-ray equipment for radiography and radioscopy. X-ray high voltage generator, mechanical protective device, protection against radiation is included in this particular requirements. Medical electrical equipment - Part 1, Part 1-2, Part 1-3 is applied to this particular requirements. If the requirements is announced as notification, It is expected to widen understanding for basic safety and essential performance of X-ray equipment for radiography and radioscopy and play a part to internationalize of medical equipment

  7. Radiation protection and safety in industrial radiography

    International Nuclear Information System (INIS)

    1999-01-01

    The use of ionizing radiation, particularly in medicine and industry, is growing throughout the world, with further expansion likely as technical developments result from research. One of the longest established applications of ionizing radiation is industrial radiography, which uses both X radiation and gamma radiation to investigate the integrity of equipment and structures. Industrial radiography is widespread in almost all Member States. It is indispensable to the quality assurance required in modern engineering practice and features in the work of multinational companies and small businesses alike. Industrial radiography is extremely versatile. The equipment required is relatively inexpensive and simple to operate. It may be highly portable and capable of being operated by a single worker in a wide range of different conditions, such as at remote construction sites, offshore locations and cross-country pipelines as well as in complex fabrication facilities. The associated hazards demand that safe working practices be developed in order to minimize the potential exposure of radiographers and other persons who may be in the vicinity of the work. The use of shielded enclosures (fixed facilities), with effective safety devices, significantly reduces any radiation exposures arising from the work. This Safety Report summarizes good and current state of the art practices in industrial radiography and provides technical advice on radiation protection and safety. It contains information for Regulatory Authorities, operating organizations, workers, equipment manufacturers and client organizations, with the intention of explaining their responsibilities and means to enhance radiation protection and safety in industrial radiography

  8. Radiation safety for site radiography

    International Nuclear Information System (INIS)

    1986-01-01

    This guidance is an update of the 1975 Code of Practice for Site Radiography and is for the use of employers and their radiographers who carry out site work. The subject is discussed under the following headings: Administrative organization, Personnel requirements, Equipment (x-ray and gamma-ray equipment, security, pipeline crawler equipment and safety equipment) Work methods and monitoring, Carriage of sources, Contingency plans, Legal considerations. (U.K.)

  9. Radiation Safety in Industrial Radiography. Specific Safety Guide (Spanish Edition); Seguridad radiologica en la radiografia industrial

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-12-15

    This Safety Guide provides recommendations for ensuring radiation safety in industrial radiography used in non-destructive testing. This includes industrial radiography work that utilizes X ray and gamma sources, both in shielded facilities that have effective engineering controls and in outside shielded facilities using mobile sources. Contents: 1. Introduction; 2. Duties and responsibilities; 3. Safety assessment; 4. Radiation protection programme; 5. Training and qualification; 6. Individual monitoring of workers; 7. Workplace monitoring; 8. Control of radioactive sources; 9. Safety of industrial radiography sources and exposure devices; 10. Radiography in shielded enclosures; 11. Site radiography; 12. Transport of radioactive sources; 13. Emergency preparedness and response; Appendix: IAEA categorization of radioactive sources; Annex I: Example safety assessment; Annex II: Overview of industrial radiography sources and equipment; Annex III: Examples of accidents in industrial radiography.

  10. Safety procedures for radiography works

    International Nuclear Information System (INIS)

    Abd Nasir Ibrahim; Azali Muhammad; Ab Razak Hamzah; Abd Aziz Mohamed; Mohammad Pauzi Ismail

    2004-01-01

    The following subjects are discussed - Work preparation: before exposure, during exposure, after work completion. Radiographic work at the open site: types of open sites, establishment of radiographic boundary, storage of radiographic equipment at sites. Safety procedures for radiography works; radiographic works in exposure room

  11. Equipment for x- and gamma ray radiography

    International Nuclear Information System (INIS)

    Abd Nasir Ibrahim; Azali Muhammad; Ab Razak Hamzah; Abd Aziz Mohamed; Mohammad Pauzi Ismail

    2004-01-01

    The following topics related to the equipment for x - and gamma ray radiography are discussed in this chapter. The topics are x-ray source for Industrial Radiography: properties of x-ray, generation of x-ray, mechanism of x-ray production, x-ray equipment, power supply, distribution of x-ray intensity along the tube: gamma ray source for Industrial Radiography: properties of gamma rays, gamma ray sources, gamma ray projectors on cameras, source changing. Care of Radiographic Equipments: Merits and Demerits of x and Gamma Rays

  12. Radiological safety aspects of industrial radiography

    International Nuclear Information System (INIS)

    Hanekom, A.P.

    1983-01-01

    Industrial radiography and especially gamma-radiography, has established itself as a very powerful tool in non-destructive testing. Unfortunately there is an amount of risk attached to the use of industrial radiography. The primary causes of radiography accidents include: working conditions, equipment failure and lack of supervisory control. To alleviate the radiological risks involved with gamma-radiography, the Atomic Energy Corporation (AEC) has imposed various conditions for the possession, use, and conveyance of radioactive material. This includes personnel training and equipment specifications

  13. Bacteriological research for the contamination of equipment in chest radiography

    International Nuclear Information System (INIS)

    Choi, Seung Gu; Song, Woon Heung; Kweon, Dae Cheol

    2015-01-01

    The purpose is to determine the degree of contamination of the equipment for infection control in chest radiography of the radiology department. We confirmed by chemical and bacterial identification of bacteria of the equipment and established a preventive maintenance plan. Chest X-ray radiography contact area on the instrument patients shoulder, hand, chin, chest lateral radiography patient contact areas with a 70% isopropyl alcohol cotton swab were compared to identify the bacteria before and after sterilization on the patient contact area in the chest radiography equipment of the department. The gram positive Staphylococcus was isolated from side shoots handle before disinfection in the chest radiography equipment. For the final identification of antibiotic tested that it was determined by performing the nobobiocin to the sensitive Staphylococcus epidermidis. Chest radiography equipment before disinfecting the handle side of Staphylococcus epidermidis bacteria were detected using a disinfectant should be to prevent hospital infections

  14. Bacteriological research for the contamination of equipment in chest radiography

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Seung Gu; Song, Woon Heung; Kweon, Dae Cheol [Shinhan University, Uijeongbu (Korea, Republic of)

    2015-12-15

    The purpose is to determine the degree of contamination of the equipment for infection control in chest radiography of the radiology department. We confirmed by chemical and bacterial identification of bacteria of the equipment and established a preventive maintenance plan. Chest X-ray radiography contact area on the instrument patients shoulder, hand, chin, chest lateral radiography patient contact areas with a 70% isopropyl alcohol cotton swab were compared to identify the bacteria before and after sterilization on the patient contact area in the chest radiography equipment of the department. The gram positive Staphylococcus was isolated from side shoots handle before disinfection in the chest radiography equipment. For the final identification of antibiotic tested that it was determined by performing the nobobiocin to the sensitive Staphylococcus epidermidis. Chest radiography equipment before disinfecting the handle side of Staphylococcus epidermidis bacteria were detected using a disinfectant should be to prevent hospital infections.

  15. Industrial Radiography Safety in Australia

    International Nuclear Information System (INIS)

    Hockings, Colin

    2006-01-01

    400 μSv average for industrial radiographers in a developed country such as the United Kingdom (NRPB 2005), it is less than that reported for a developing country such as Iran (AEOI 2004), which is 1650 μSv. Industrial radiography accidents most frequently occur with radiation devices using sealed sources such as iridium 192 and cobalt 60, and not with x-ray generators. In comparison to other countries, the safety record of industrial radiographers as judged by accident data and dose records, places Australia somewhere between that of an advanced country and a developing one. Many of the investigations into accidents in industrial radiography have revealed that their frequency and severity would have been reduced or even eliminated if the persons involved had been better prepared to use the equipment, and better prepared to deal with accident and incident situations. In Australia, there appears to be scope for improvement and standardisation of training in the use of industrial radiography equipment, and more importantly, in the training for response to possible accidents and incidents. A national standard for radiation safety training and assessment should be developed by a competent organisation such as the Australian Institute for Non-Destructive Testing. It should be incorporated into the Code of Practice or Safety Guide for industrial radiography and adopted by all jurisdictions. The use of a code of safe practice for industrial radiography should continue. The present NH and MRC code is in need of review. Such a review must result in a code and a guideline document which are readily useable by the industry, standardise training in radiation safety, ensure a high level of operational radiation safety and are available for adoption by the various Australian jurisdictions with minimal supplementary local requirements. Copyright (2006) The Australian Institute for Non-Destructive Testing

  16. A range of equipment for dental radiography

    International Nuclear Information System (INIS)

    Bergman, G.P.M.; Clement, S.L.

    1980-01-01

    A brief review of the history of dental radiography is followed by a description of the latest Philips equipment, ranging from compact units for intra-oral radiography to advanced systems for panoramic techniques and skull radiography. The advantages of automatic exposure control and automatic film processing are also discussed. In conclusion, some probable future trends are forecast. (Auth.)

  17. Safety culture in industrial radiography facility

    International Nuclear Information System (INIS)

    Vincent-Furo, Evelyn

    2015-02-01

    This project reviewed published IAEA materials and other documents on safety culture with specific references to industrial radiography. Safety culture requires all duties important to safety to be carried out correctly, with alertness, due thought and full knowledge, sound judgment and a proper sense of accountability. The development and maintenance of safety culture in an operating organization has to cover management systems, policies, responsibilities, procedures and organizational arrangements. The essence is to control radiation hazard, optimize radiation protection to prevent or reduce exposures and mitigate the consequences of accidents and incidents. To achieve a high degree of safety culture appropriate national and international infrastructure should exist to ensure effective training of workers and management system that supports commitment to safety culture at all level of the organization; management, managers and workforce. The result of the review revealed that all accidents in industrial radiography facilities were due to poor safety culture practices including inadequate regulatory control oversight. Some recommendations are provided and if implemented could improve safety culture leading to good safety performance which will significantly reduce accidents and their consequences in industrial radiography. These examples call for a review of safety culture in Industrial radiography. (au)

  18. Industrial radiography

    International Nuclear Information System (INIS)

    1994-01-01

    This Health and Safety Executive Information Sheet on industrial radiography aims to inform directors and managers of industrial radiography companies on the safety precautions necessary to ensure that their personnel do not exceed dose guidelines for exposure to ionizing radiation. The Ionising Radiations Regulations 1985 (IRR85) require that exposure doses for radiographers are kept as low reasonably practicable. Equipment maintenance, and the employment of proper emergency procedures will help to ensure personnel safety. (UK)

  19. Analysis of bacterial contamination on surface of general radiography equipment and CT equipment in emergency room of radiology

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Dong Hee; KIm, Hyeong Gyun [Dept. of Radiological Science, Far East University, Eumseong (Korea, Republic of)

    2016-09-15

    We aim to offer basic materials about infection management through conducting bacterial contamination test about general radiography equipment and CT equipment installed in ER of three general hospitals with 100 sickbeds or more located in Gyeongsangbuk-do Province, and suggest management plan. It had been conducted from 1st December 2015 to 31st December, and objects were general radiography equipment and CT equipment of emergency room located in Gyeongsangbuk-do Province. For general radiography equipment, sources were collected from 4 places such as upper side of control box which employees use most, upper side of exposure button, whole upper side of table which is touching part of patient's skin, upper side of stand bucky's grid, and where patients put their jaws on. For CT equipment, sources were collected from 3 places such as upper side of control box which radiography room employees use most, X-ray exposure button, whole upper side of table which is touching part of patient's skin, and gantry inner. Surface contamination strain found at general radiography equipment in emergency room of radiology are Providencia stuartii(25%), Stenotrophomonas maltophilia(18%), Enterobacter cloacae(8%), Pseudomonas species(8%), Staphylococcus epidermidis(8%), Gram negative bacilli(8%), and ungrown bacteria at incubator after 48 hours of incubation (67%) which is the biggest. Most bacteria were found at upper side of stand bucky-grid and stand bucky of radiology's general radiography equipment, and most sources of CT equipment were focused at patient table, which means it is contaminated by patients who have various diseases, and patients who have strains with decreased immunity may get severe diseases. Thus infection prevention should be made through 70% alcohol disinfection at both before test and after test.

  20. Analysis of bacterial contamination on surface of general radiography equipment and CT equipment in emergency room of radiology

    International Nuclear Information System (INIS)

    Hong, Dong Hee; KIm, Hyeong Gyun

    2016-01-01

    We aim to offer basic materials about infection management through conducting bacterial contamination test about general radiography equipment and CT equipment installed in ER of three general hospitals with 100 sickbeds or more located in Gyeongsangbuk-do Province, and suggest management plan. It had been conducted from 1st December 2015 to 31st December, and objects were general radiography equipment and CT equipment of emergency room located in Gyeongsangbuk-do Province. For general radiography equipment, sources were collected from 4 places such as upper side of control box which employees use most, upper side of exposure button, whole upper side of table which is touching part of patient's skin, upper side of stand bucky's grid, and where patients put their jaws on. For CT equipment, sources were collected from 3 places such as upper side of control box which radiography room employees use most, X-ray exposure button, whole upper side of table which is touching part of patient's skin, and gantry inner. Surface contamination strain found at general radiography equipment in emergency room of radiology are Providencia stuartii(25%), Stenotrophomonas maltophilia(18%), Enterobacter cloacae(8%), Pseudomonas species(8%), Staphylococcus epidermidis(8%), Gram negative bacilli(8%), and ungrown bacteria at incubator after 48 hours of incubation (67%) which is the biggest. Most bacteria were found at upper side of stand bucky-grid and stand bucky of radiology's general radiography equipment, and most sources of CT equipment were focused at patient table, which means it is contaminated by patients who have various diseases, and patients who have strains with decreased immunity may get severe diseases. Thus infection prevention should be made through 70% alcohol disinfection at both before test and after test

  1. Code of practice for the safe use of industrial radiography equipment (1989)

    International Nuclear Information System (INIS)

    1989-12-01

    This code supersedes the Code of practice for the control and safe handling of sealed radioactive sources used in industrial radiography, published by the National Health and Medical Research Council (NHMRC) in 1968. It differs significantly from the former code because radiation protection practice and recommended standards have changed. The code covers the design, construction and requirements for the safe use of X-radiography equipment and gamma-radiography equipment. It provides illustrative working rules, detailed emergency procedures and comprehensive responsibilities and duties for all personnel involved in supplying and using industrial radiography equipment. The code details those equipment requirements, personnel requirements and work practices that the NHMRC considers necessary to keep exposures to ionizing radiation as low as reasonably achievable. Some equipment and facilities currently in use may not meet all of the mandatory requirements of this code. These requirements have been included in the code to encourage progress towards future compliance in the expectation that, in the interim, statutory authorities will apply them with discretion

  2. Gamma radiography and its technological application

    International Nuclear Information System (INIS)

    Courtois, G.

    1962-01-01

    After the presentation of gamma radiography and X-ray radiography, the author compare both techniques showing, in particular, the greater utility of gamma radiography in industrial diagnostic and more particularly on works site diagnostic. Problem of using radiography and safety consideration will be studied. Figures shows two radiography equipment which have been designed for gamma radiography respecting the safety regulations required by the Radioisotope Inter-ministerial Commission. In the second part, different techniques and uses of gamma radiography are briefly described : xerography, neutron radiography, fluoroscopy and imaging amplifier, tomography, betatrons and linear accelerators. Cost analysis will discussed in conclusion. (M.P.)

  3. Code of practice for the safe use of industrial radiography equipment (1989)

    International Nuclear Information System (INIS)

    1989-12-01

    This code supersedes the Code of Practice for the control and safe handling of sealed radioactive sources use din industrial radiography, published by the National Health and Medical Research Council (NHMRC) in 1968. It differs significantly from the former code because radiation protection practice and recommended standards have changed. The code covers the design, construction and requirements for the safe use of X-radiography equipment and gamma-radiography equipment. It provides illustrative working rules, detailed emergency procedures and comprehensive responsibilities and duties for all personnel involved in supplying and using industrial radiography equipment. The code details those equipment requirements, personnel requirements and work practices that the NHMRC considers necessary to keep exposures to ionizing radiation as low as reasonably achievable. Some equipment and facilities currently in use may not meet all of the mandatory requirements of this code. These requirements have been included in the code to encourage progress towards future compliance in the expectation that, in the interim, statutory authorities will apply them with discretion. 9 refs., tabs., ills

  4. 10 CFR 34.42 - Radiation Safety Officer for industrial radiography.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Radiation Safety Officer for industrial radiography. 34.42 Section 34.42 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION... Radiation Safety Officer for industrial radiography. The RSO shall ensure that radiation safety activities...

  5. A preliminary design of mechanical device on industrial digital radiography equipment design

    International Nuclear Information System (INIS)

    Nur Khasan; Samuel Praptoyo

    2015-01-01

    A preliminary design of mechanical device on industrial digital radiography equipment has been done. this design is intended as a basis for the manufacture of complete facilities for the realization a prototype on industrial digital radiography equipment. the design and construction were carried out by paying attention to the general configuration of the basic design in which its mechanical design has several components with specific dimensions and heavy mass. this design consist of a main frame holder, flat panel detector support and hydraulic hand stacker for mounting the x-ray machine. this mechanical device design will then be fabricated to facilitate and assist work of digital radiographic retrieval. computer application programs sketch-up is used to draw this design and the analysis stress of autodesk inventor to analysis the strength construction design. the results of this design are the configuration drawing, sketch drawings of construction and the safety factor of construction design with a minimum value of 2.39 as well as a maximum value of 15 when to be simulated by the load 500 Kg which is 4 times of total workload. (author)

  6. Report based on fiscal 2000 diagnostic X-ray equipment questionnaire survey. Conditions of radiography

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, Mitsuo [Kitasato Univ., Sagamihara, Kanagawa (Japan). School of Allied Health Sciences; Matsuura, Takatoshi [Sekishinkai Sayama Hospital, Saitama (Japan); Okuaki, Tomoyuki; Imai, Yoshio; Tsukamoto, Atsuko [Kanto Medical Center NTT EC, Tokyo (Japan); Ide, Toshinori [Kajima Corp., Tokyo (Japan). Kajima Clinic; Shinohara, Fuminori [Nippon Medical School, Kawasaki, Kanagawa (Japan). Second Hospital; Miyazaki, Shigeru [Toho Univ., Tokyo (Japan). Ohashi Hospital

    2002-08-01

    X-ray equipment has seen advances in inverters and the digitalization of reception systems. The X-ray Systems Study Group, in order to examine changes in the conditions of radiography, including pediatric radiography, variations in shortest irradiation time, and standardization of the conditions of radiography, carried out investigative research using a questionnaire survey that was sent to 400 facilities. The recovery rate was 33%. In terms of the reception system, half of the general radiography systems were using computed radiography (CR). Seventy percent of respondents used an intensifying screen and film (SEF) in stomach double-contrast radiography. About 80% used digital radiography (DR) and digital subtraction angiography (DSA) in aorta abdominalis angiography. At least 70% of high-voltage generators were of the inverter type. The conditions of radiography were not greatly influenced by changes in reception systems and X-ray equipment. Many pediatric radiographies were carried out by radiological technologists. We consider it useful to conduct such survey investigations. (author)

  7. [Report based on fiscal 2000 diagnostic x-ray equipment questionnaire survey(conditions of radiography)].

    Science.gov (United States)

    Ishikawa, Mitsuo; Matsuura, Takatoshi; Okuaki, Tomiyuki; Imai, Yoshio; Tsukamoto, Atsuko; Ide, Toshinori; Shinohara, Fuminori; Miyazaki, Shigeru

    2002-08-01

    X-ray equipment has seen advances in inverters and the digitalization of reception systems. The X-ray Systems Study Group, in order to examine changes in the conditions of radiography, including pediatric radiography, variations in shortest irradiation time, and standardization of the conditions of radiography, carried out investigative research using a questionnaire survey that was sent to 400 facilities. The recovery rate was 33%. In terms of the reception system, half of the general radiography systems were using computed radiography (CR). Seventy percent of respondents used an intensifying screen and film(S EF)in stomach double-contrast radiography. About 80% used digital radiography (DR) and digital subtraction angiography (DSA) in aorta abdominalis angiography. At least 70% of high-voltage generators were of the inverter type. The conditions of radiography were not greatly influenced by changes in reception systems and X-ray equipment. Many pediatric radiographies were carried out by radiological technologists. We consider it useful to conduct such survey investigations.

  8. Resolution 12/2004 Guideline for implementation of safety regulations in the practice of industrial radiography

    International Nuclear Information System (INIS)

    2004-01-01

    1. This guide is intended to clarify, in relation to its application in practice Industrial Radiography, the provisions of: a) Joint Resolution CITMA-MINSAP, of December 15, 2002, Regulation: B asic Radiation Safety Standards , hereinafter Regulation NBS; b) Resolution No. 25/98 of CITMA Regulation. A uthorization Practices Associated with the use of ionizing radiation , hereinafter Resolution 25/98; c) Resolution 121/2000 CITMA Regulation: F or the Safe Transport of Radioactive materials , hereinafter Resolution 121/2000; and in d) Joint Resolution CITMA-MINSAP, Regulation: S election, Training and Authorization of personnel performing Employment Practices Associated Radiation Ionizing . 2. For the purposes of applying this Guide considers the practice of Industrial Radiography includes the following techniques: a) Industrial Radiography with use of gamma radiation sources; b) crawler radiography equipment; and c) Industrial Radiography with X-rays

  9. Decree No85-968 of 27 August 1986 amending Article R.233-83 of the Labour Code and defining the health and safety conditions to be met by gamma industrial radiography equipment

    International Nuclear Information System (INIS)

    1986-01-01

    This Decree, amending Article R 233-83 of the Labour Code, applies to gamma-ray industrial radiography equipment whether mobile or fixed. It contains specific technical conditions concerning the equipment, in particular, safety devices located at the entry and exit points of the source's shield. The equipment must carry a notice mentioning''Radioactive''prepared by the constructor or the importer of the source, which explains the conditions for handling, setting-up, use and maintenance of the source, including the frequency of revisions. The Decree entered into force on 1 June 1986. (NEA) [fr

  10. Rules on the Inspection of Gamma Radiography Equipment

    International Nuclear Information System (INIS)

    1981-01-01

    These Rules issued by the State Institute of Radiation Hygiene (SIS) set out the obligations of licences and vendors of gamma radiography equipment for purposes of quality control. The Rules provide for a programme of periodic inspections and services by personnel approved by SIS. (NEA)

  11. Gamma radiography and its technological application; Gammagraphie et techniques annexes

    Energy Technology Data Exchange (ETDEWEB)

    Courtois, G [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1962-07-01

    After the presentation of gamma radiography and X-ray radiography, the author compare both techniques showing, in particular, the greater utility of gamma radiography in industrial diagnostic and more particularly on works site diagnostic. Problem of using radiography and safety consideration will be studied. Figures shows two radiography equipment which have been designed for gamma radiography respecting the safety regulations required by the Radioisotope Inter-ministerial Commission. In the second part, different techniques and uses of gamma radiography are briefly described : xerography, neutron radiography, fluoroscopy and imaging amplifier, tomography, betatrons and linear accelerators. Cost analysis will discussed in conclusion. (M.P.)

  12. Regulation EM-GT-7. Quality control of the radiography equipment

    International Nuclear Information System (INIS)

    2015-01-01

    The purpose of this document is to provide practical guidance of technical procedures for carrying out quality control in X-ray equipment. This guide is applicable to general purpose radiography equipment, although some of the procedures may be applied to other types of diagnostic imaging equipment. The tests described require the appointed instrumentation and some of these can be implemented in the radiodiagnostic given the simplicity of them and others require special equipment and can be performed by external specialized groups to these units.

  13. Safety lock for radiography exposure device

    International Nuclear Information System (INIS)

    Gaines, T.M.

    1982-01-01

    A safety lock for securing a radiation source in a radiography exposure device is disclosed. The safety lock prevents the inadvertent extension of the radiation source from the exposure device. The exposure devices are used extensively in industry for nondestructive testing of metal materials for defect. Unnecessary exposure of the radiographer or operator occurs not infrequently due to operator's error in believing that the radiation source is secured in the exposure device when, in fact, it is not. The present invention solves this problem of unnecessary exposure by releasingly trapping the radiation source in the shield of the radiography exposure device each time the source is retracted therein so that it is not inadvertently extended therefrom without the operator resetting the safety lock, thereby releasing the radiation source. Further, the safety lock includes an indicator which indicates when the source is trapped in the exposure device and also when it is untrapped. The safety lock is so designed that it does not prevent the return of the source to the trapped, shielded position in the exposure device. Further the safety lock includes a key means for locking the radiation source in the trapped position. The key means cannot be actuated until said radiation source is in said trapped position to further insure the safety lock cannot be inadvertently locked with the source untrapped and thus still extendable from the exposure device

  14. Equipment for radiography in Yugoslavia - security and radiation protection

    International Nuclear Information System (INIS)

    Dobrijevic, R.; Vucina, J.

    1998-01-01

    Nondestructive method of material control by using radioisotopes is developed in Yugoslavia. This method of quality control is professionally performed by 30 firms. This paper presents the overview of the equipment used in the industrial radiography by using radioisotopes. Special attention was devoted to the security during the work and to the radiation protection of the operator and other personnel around the working place. In general it could be concluded that the main drawback which influences the security is the fact that most cases old and whom out equipment is in use. Other factors influencing the security are also discussed. (author)

  15. Regulations providing for the inspection of gamma radiography equipment

    International Nuclear Information System (INIS)

    1981-01-01

    Pursuant to the 1938 Act on X-rays and radium, etc and the 1976 regulations on supervision and use of installations and apparatus which release radiation representing a hazard to health, the State Institute of Radiation Health issued these regulations providing for a system of periodic inspections of gamma radiography equipment for radiation protection purposes. They entered into force on 1 July 1981 [fr

  16. X-ray radiography equipment for patients in standing position

    International Nuclear Information System (INIS)

    Snijder, J.G.N.

    1974-01-01

    X-ray radiography equipment suited for patients in standing position is described. The patient's body centre of mass is indicated by its vertical projection line appearing on the X-ray image. To that end, an X-ray absorbing wire is positioned through the centre of mass by means of an electrical signal acting on a servomotor and derived from the pressure on three non-colinear points in the foot plate through an analogue computer

  17. Irradiation hazards and safety standards for patients in dental radiography

    Energy Technology Data Exchange (ETDEWEB)

    Williamson, B D.P.

    1975-07-01

    The historical developments which have led to a reduction in the hazards or potential hazards to patients in dental radiography are reviewed. Based on a simple risk estimate, the safety of present-day techniques employed in routine dental radiography is assessed. Also included in the review is a description of techniques used and results obtained from the National Radiation Laboratory's (NRL) surveillance programme of patients' exposure to irradiation in dental radiography. The possibilities of and need for achieving further reductions of irradiation are discussed.

  18. A review of digital radiography technology for valve inspection

    International Nuclear Information System (INIS)

    Stoev, K.; Guerout, F.M.; Horn, D.

    2008-01-01

    There are thousands of valves in a nuclear power plant (NPP) used for control, safety and checks in various plant systems, so there is a well-identified need for fast and reliable inspection and diagnostics of valves. Digital radiography can provide considerable improvements to the inspection and testing procedures for valves in comparison to classical film radiography. These improvements can lead to significant financial advantages by providing real-time inspection results, significantly reduced inspection and decision-making time, and reduced operational cost. Digital image processing, including digital image enhancement, digital archiving, and digital communication of the images and the results, is also a considerable advantage over classical film radiography technology. Another advantage of digital radiography technology is the improved safety and the reduced environmental impact due to reduced exposure/test times, use of smaller exclusion zones, elimination of chemical processing, and absence of disposable materials. This paper reviews the existing technology and evaluates the potential of digital radiography for inspection and diagnostics of valves. Station needs and requirements are assessed, and the safety, environmental and economical constraints of digital radiography techniques estimated. The advantages and disadvantages of different digital radiography equipment are compared, and their limitations and characteristics studied. (author)

  19. Industrial radiography in the Philippines: safety concerns

    International Nuclear Information System (INIS)

    David, Jocelyn L.; Artificio, Thelma P.; Cerbolles, Justina S.; Caseria, Estrella S.; Agron, Inocencio A.

    2005-01-01

    Industrial radiography utilizes the highest activity (5.55 tera becquerel (TBq) to 7.4 TBq) among the various mobile application of radioisotopes. It is highly possible that radiographers exceed the annual dose limits for workers occupationally exposed to radiation (as prescribed in the Code of PNRI Regulations part 3) if they do not give cautious consideration to the factors that determine the radiation dose, namely: the gamma source dose rates, time distance and shielding. To enhance the safety culture among radiographers, various strategies are recommended to be undertaken by the Philippine Nuclear Research Institute as well as the licensed companies undertaking activities in industrial radiography. (Authors)

  20. Radiation safety in welding and testing

    International Nuclear Information System (INIS)

    King, B.E.; Malaxos, M.; Hartley, B.M.

    1985-01-01

    There are a number of ways of achieving radiation safety in the workplace. The first is by engineering radiation safety into the equipment, providing shielded rooms and safety interlocks. The second is by following safe working procedures. The National Health and Medical Research Council's Code of practice for the control and safe handling of sealed radioactive sources used in industrial radiography (1968) sets out the standards which must be met by equipment to be used in industrial radiography

  1. Radiography

    Science.gov (United States)

    Gardner, C. G.

    1973-01-01

    Radiography is discussed as a method for nondestructive evaluation of internal flaws of solids. Gamma ray and X-ray equipment are described along with radiographic film, radiograph interpretation, and neutron radiography.

  2. Radiation protection in dentistry. Recommended safety procedures for the use of dental x-ray equipment. Safety code 30

    International Nuclear Information System (INIS)

    1994-01-01

    The Radiation Protection Bureau has prepared a series of documents on safety codes to set out requirements for the safe use of radiation-emitting equipment. This Safety Code has been prepared to provide specific guidance to the dentist, dental hygienist, dental assistant and other support personnel concerned with safety procedures and equipment performance. Dental radiography is one of the most valuable tools used in modern dental health care. It makes possible the diagnosis of physical conditions that would otherwise be difficult to identify. The use of dental radiological procedures must be carefully managed, because x-radiation has the potential for damaging healthy cells and tissues. Although no known occurrence of cancer or genetic damage has been observed from radiation doses delivered in modern dentistry, and until more evidence is available, one should practice radiation hygiene with the same care as would be dictated if a hazard were known to exist. The aim of radiation protection in dentistry is to obtain the desired clinical information with minimal radiation exposure to patients, dental personnel and the public. 15 tabs

  3. Radiation protection in dentistry. Recommended safety procedures for the use of dental x-ray equipment. Safety code 30

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-31

    The Radiation Protection Bureau has prepared a series of documents on safety codes to set out requirements for the safe use of radiation-emitting equipment. This Safety Code has been prepared to provide specific guidance to the dentist, dental hygienist, dental assistant and other support personnel concerned with safety procedures and equipment performance. Dental radiography is one of the most valuable tools used in modern dental health care. It makes possible the diagnosis of physical conditions that would otherwise be difficult to identify. The use of dental radiological procedures must be carefully managed, because x-radiation has the potential for damaging healthy cells and tissues. Although no known occurrence of cancer or genetic damage has been observed from radiation doses delivered in modern dentistry, and until more evidence is available, one should practice radiation hygiene with the same care as would be dictated if a hazard were known to exist. The aim of radiation protection in dentistry is to obtain the desired clinical information with minimal radiation exposure to patients, dental personnel and the public. 15 tabs.

  4. Development of Safety Kit for Industrial Radiography Application

    International Nuclear Information System (INIS)

    Mohd Noorul Ikhsan Ahmad; Amry Amin Abas

    2011-01-01

    A safety kit for industrial radiography has been developed. The safety kit that consist of a set of technical rod and various size of base that can be used in radiograph of pipe with diameter between half and one and half inch with utilization of collimator. With the kit, radiographers will not having anymore problem to use collimator in their work. The paper discuss about the technical measures of the safety kit and the importance of introducing it to the industry. (author)

  5. Preliminary results from the application of risk matrix method for safety assessment in industrial radiography

    International Nuclear Information System (INIS)

    Lopez G, A.; Cruz, D.; Truppa, W.; Aravena, M.; Tamayo, B.

    2015-09-01

    Although the uses of ionizing radiation in industry are subject to procedures that provide a high level of safety, experience has shown that equipment failure, human errors, or the combination of both that can trigger accidental exposures may occur. Traditionally, the radiation safety checks whether these industrial practices (industrial radiography, industrial irradiators, among others) are sufficiently safe to prevent similar accidental exposures already occurred, so that becomes dependent on the published information and not always answers questions like: What other events can occur, or what other risks are present? Taking into account the results achieved by the Foro Iberoamericano de Organismos Reguladores Radiologicos y Nucleares, its leading position in the use of techniques of risk analysis in radioactive facilities and the need to develop a proactive approach to the prevention of accidents arising from the use of ionizing radiations in the industry, it intends to apply the risk analysis technique known as Risk Matrix to a hypothetical reference entity for the region in which industrial radiography is performed. In this paper the results of the first stage of this study are shown, that is the identification of initiating events (IE) and barriers that help mitigate the consequences of such IE, so that can appreciate the applicability of this method to industrial radiography services, to reduce the risk to acceptable levels. The fundamental advantage associated with the application of this methodology is that can be applied by the professionals working in the service and identifies specific weaknesses that from the point of view of safety there, so they can be prioritized resources depending on risk reduction. (Author)

  6. Pediatric interventional radiography equipment: safety considerations

    International Nuclear Information System (INIS)

    Strauss, Keith J.

    2006-01-01

    This paper discusses pediatric image quality and radiation dose considerations in state-of-the-art fluoroscopic imaging equipment. Although most fluoroscopes are capable of automatically providing good image quality on infants, toddlers, and small children, excessive radiation dose levels can result from design deficiencies of the imaging device or inappropriate configuration of the equipment's capabilities when imaging small body parts. Important design features and setup choices at installation and during the clinical use of the imaging device can improve image quality and reduce radiation exposure levels in pediatric patients. Pediatric radiologists and cardiologists, with the help of medical physicists, need to understand the issues involved in creating good image quality at reasonable pediatric patient doses. The control of radiographic technique factors by the generator of the imaging device must provide a large dynamic range of mAs values per exposure pulse during both fluoroscopy and image recording as a function of patient girth, which is the thickness of the patient in the posterior-anterior projection at the umbilicus (less than 10 cm to greater than 30 cm). The range of pulse widths must be limited to less than 10 ms in children to properly freeze patient motion. Variable rate pulsed fluoroscopy can be leveraged to reduce radiation dose to the patient and improve image quality. Three focal spots with nominal sizes of 0.3 mm to 1 mm are necessary on the pediatric unit. A second, lateral imaging plane might be necessary because of the child's limited tolerance of contrast medium. Spectral and spatial beam shaping can improve image quality while reducing the radiation dose. Finally, the level of entrance exposure to the image receptor of the fluoroscope as a function of operator choices, of added filter thickness, of selected pulse rate, of the selected field-of-view and of the patient girth all must be addressed at installation. (orig.)

  7. Seismic qualification of non-safety class equipment whose failure would damage safety class equipment

    International Nuclear Information System (INIS)

    LaSalle, F.R.

    1991-01-01

    Both Code of Federal Regulations, Title 10, Part 50, and US Department of Energy Order 6340.1A have requirements to assess the interaction of non-safety and safety class structures and equipment during a seismic event to maintain the safety function. At the Hanford Site, a cost effective program has been developed to perform the evaluation of non-safety class equipment. Seismic qualification is performed by analysis, test, or upgrading of the equipment to ensure the integrity of safety class structures and equipment. This paper gives a brief overview and synopsis that address design analysis guidelines including applied loading, damping values, component anchorage, allowable loads, and stresses. Test qualification of equipment and walkdown acceptance criteria for heating ampersand ventilation (H ampersand V) ducting, conduit, cable tray, missile zone of influence, as well as energy criteria are presented

  8. Patient safety in undergraduate radiography curricula: A European perspective

    International Nuclear Information System (INIS)

    England, A.; Azevedo, K.B.; Bezzina, P.; Henner, A.; McNulty, J.P.

    2016-01-01

    Purpose: To establish an understanding of patient safety within radiography education across Europe by surveying higher education institutions registered as affiliate members of the European Federation of Radiographer Societies (EFRS). Method: An online survey was developed to ascertain data on: programme type, patient safety definitions, relevant safety topics, specific areas taught, teaching and assessment methods, levels of teaching and curriculum drivers. Responses were identifiable in terms of educational institution and country. All 54 affiliated educational institutions were invited to participate. Descriptive and thematic analyses are reported. Results: A response rate of 61.1% (n = 33) was achieved from educational institutions representing 19 countries. Patient safety topics appear to be extremely well covered across curricula, however, topics including radiation protection and optimisation were not reported as being taught at an ‘advanced level’ by five and twelve respondents, respectively. Respondents identified the clinical department as the location of most patient safety-related teaching. Conclusions: Patient safety topics are deeply embedded within radiography curricula across Europe. Variations exist in terms of individual safety topics including, teaching and assessment methods, and the depth in which subjects are taught. Results from this study provide a baseline for assessing developments in curricula and can also serve as a benchmark for comparisons. - Highlights: • First European report on patient safety (PS). • PS deeply embedded within training curricula. • Terms and definitions largely consistent. • Some variety in the delivery and assessment methods. • Report provides baseline and opportunities for comparisons.

  9. Requirements for industrial x-ray equipment

    International Nuclear Information System (INIS)

    1987-01-01

    This safety code is concerned with the protection of all individuals who may be exposed to radiation emitted by X-ray equipment operating at energies up to 1 MeV as used in industrial radiography. This code presents basic radiation safety information for the protection of personnel operating and servicing X-ray equipment and other workers and the general public in the vicinity of areas where X-ray equipment is in operation. It specifies general safety features of design, construction and functioning of X-ray equipment and facilities; describes the responsibilities of the user, operator and maintenance personnel; contains recommendations to ensure that the X-ray equipment is used and maintained in accordance with the ALARA principle; and describes a program of personnel monitoring and radiation safety surveys. ( 6 refs., 5 tabs., 4 figs.)

  10. Discussion on the safety classification of nuclear safety mechanical equipment

    International Nuclear Information System (INIS)

    Shen Wei

    2010-01-01

    The purpose and definition of the equipment safety classification in nuclear plant are introduced. The differences of several safety classification criterions are compared, and the object of safety classification is determined. According to the regulation, the definition and category of the safety functions are represented. The safety classification method, safety classification process, safety class interface, and the requirement for the safety class mechanical equipment are explored. At last, the relation of the safety classification between the mechanical and electrical equipment is presented, and the relation of the safety classification between mechanical equipment and system is also presented. (author)

  11. Assessing the Oldness and Capacity of Radiography and Ultrasound Equipments in Tehran University of Medical Sciences

    International Nuclear Information System (INIS)

    Salamati, Payman; Ghanaati, Hossein; Ghasemzadeh, Shahram; Jalali, Amir Hossein

    2013-01-01

    Maintenance of imaging equipment is a very important part of the management of all medical imaging centers. To assess the oldness and capacity of radiography and ultrasound equipment in Tehran University of Medical Sciences. The study was performed in 16 hospitals, 4 faculties and three healthcare centers of Tehran University of Medical Sciences. We evaluated all the X-ray equipment (including the simple plain and dental, panorex, mammography, fluoroscopy and C-arm X-Ray devices) and also simple and Doppler ultrasound machines in terms of the type and usage of the device, production year, quantity of utilization, location, brand and current condition. Among fixed X-ray systems, 15 were currently in use, two were junk, two were damaged, and one was not utilized. The mean (SD) of the usage of these was 2151 (2230) cliché/month, and the mean (SD) of the oldness was 16.9 (13.6) years. The oldness of radiography equipment in our study was more than 20 years in 16, between 11 and 20 in 46, and less than 10 years in 76 devices. The mean (SD) usage (patients/month) of simple and color Doppler devices were 234.1 (365.2) and 597.5 (505.3), respectively. The oldness of ultrasonography equipment in our study was more than 11 years in 12 and less than 10 years in 55 devices. We found that 22 (15.9%) of the radiography systems and two (3%) of the ultrasonography systems had been used for more than 20 years. Radiology equipment in Tehran University of Medical Sciences have potential capacity, but they need repair, and better maintenance and management and application of standards for the imaging system needs organized supervisory mechanisms

  12. Evaluation of radiation dose to patients in intraoral dental radiography using Monte Carlo Method

    International Nuclear Information System (INIS)

    Park, Il; Kim, Kyeong Ho; Oh, Seung Chul; Song, Ji Young

    2016-01-01

    The use of dental radiographic examinations is common although radiation dose resulting from the dental radiography is relatively small. Therefore, it is required to evaluate radiation dose from the dental radiography for radiation safety purpose. The objectives of the present study were to develop dosimetry method for intraoral dental radiography using a Monte Carlo method based radiation transport code and to calculate organ doses and effective doses of patients from different types of intraoral radiographies. Radiological properties of dental radiography equipment were characterized for the evaluation of patient radiation dose. The properties including x-ray energy spectrum were simulated using MCNP code. Organ doses and effective doses to patients were calculated by MCNP simulation with computational adult phantoms. At the typical equipment settings (60 kVp, 7 mA, and 0.12 sec), the entrance air kerma was 1.79 mGy and the measured half value layer was 1.82 mm. The half value layer calculated by MCNP simulation was well agreed with the measurement values. Effective doses from intraoral radiographies ranged from 1 μSv for maxilla premolar to 3 μSv for maxilla incisor. Oral cavity layer (23⁓82 μSv) and salivary glands (10⁓68 μSv) received relatively high radiation dose. Thyroid also received high radiation dose (3⁓47 μSv) for examinations. The developed dosimetry method and evaluated radiation doses in this study can be utilized for policy making, patient dose management, and development of low-dose equipment. In addition, this study can ultimately contribute to decrease radiation dose to patients for radiation safety

  13. Evaluation of radiation dose to patients in intraoral dental radiography using Monte Carlo Method

    Energy Technology Data Exchange (ETDEWEB)

    Park, Il; Kim, Kyeong Ho; Oh, Seung Chul; Song, Ji Young [Dept. of Nuclear Engineering, Kyung Hee University, Yongin (Korea, Republic of)

    2016-11-15

    The use of dental radiographic examinations is common although radiation dose resulting from the dental radiography is relatively small. Therefore, it is required to evaluate radiation dose from the dental radiography for radiation safety purpose. The objectives of the present study were to develop dosimetry method for intraoral dental radiography using a Monte Carlo method based radiation transport code and to calculate organ doses and effective doses of patients from different types of intraoral radiographies. Radiological properties of dental radiography equipment were characterized for the evaluation of patient radiation dose. The properties including x-ray energy spectrum were simulated using MCNP code. Organ doses and effective doses to patients were calculated by MCNP simulation with computational adult phantoms. At the typical equipment settings (60 kVp, 7 mA, and 0.12 sec), the entrance air kerma was 1.79 mGy and the measured half value layer was 1.82 mm. The half value layer calculated by MCNP simulation was well agreed with the measurement values. Effective doses from intraoral radiographies ranged from 1 μSv for maxilla premolar to 3 μSv for maxilla incisor. Oral cavity layer (23⁓82 μSv) and salivary glands (10⁓68 μSv) received relatively high radiation dose. Thyroid also received high radiation dose (3⁓47 μSv) for examinations. The developed dosimetry method and evaluated radiation doses in this study can be utilized for policy making, patient dose management, and development of low-dose equipment. In addition, this study can ultimately contribute to decrease radiation dose to patients for radiation safety.

  14. Safety Review related to Commercial Grade Digital Equipment in Safety System

    International Nuclear Information System (INIS)

    Yu, Yeongjin; Park, Hyunshin; Yu, Yeongjin; Lee, Jaeheung

    2013-01-01

    The upgrades or replacement of I and C systems on safety system typically involve digital equipment developed in accordance with non-nuclear standards. However, the use of commercial grade digital equipment could include the vulnerability for software common-mode failure, electromagnetic interference and unanticipated problems. Although guidelines and standards for dedication methods of commercial grade digital equipment are provided, there are some difficulties to apply the methods to commercial grade digital equipment for safety system. This paper focuses on regulatory guidelines and relevant documents for commercial grade digital equipment and presents safety review experiences related to commercial grade digital equipment in safety system. This paper focuses on KINS regulatory guides and relevant documents for dedication of commercial grade digital equipment and presents safety review experiences related to commercial grade digital equipment in safety system. Dedication including critical characteristics is required to use the commercial grade digital equipment on safety system in accordance with KEPIC ENB 6370 and EPRI TR-106439. The dedication process should be controlled in a configuration management process. Appropriate methods, criteria and evaluation result should be provided to verify acceptability of the commercial digital equipment used for safety function

  15. Recommended practice for the neutron radiography of nuclear fuels

    International Nuclear Information System (INIS)

    Matfield, R.S.

    1983-01-01

    The document is part of a Neutron Radiography Handbook being prepared by a Neutron Radiography Working Party of the European Community. It commences with a description of the information that should be provided by a user of neutron radiography services and then gives recommendations on the equipment to be used. This is followed by two sections on the techniques to be used for detecting discontinuities and the making of measurements on nuclear fuel. This is then followed by recommended safety practices and then sections on film handling, film processing, viewing of radiographs, references, radiographs, storage and records. Recommendations on training and certification are being prepared. It does not include any technical justification for the practices which are recommended. (Auth.)

  16. Optimization of safety equipment outages improves safety

    International Nuclear Information System (INIS)

    Cepin, Marko

    2002-01-01

    Testing and maintenance activities of safety equipment in nuclear power plants are an important potential for risk and cost reduction. An optimization method is presented based on the simulated annealing algorithm. The method determines the optimal schedule of safety equipment outages due to testing and maintenance based on minimization of selected risk measure. The mean value of the selected time dependent risk measure represents the objective function of the optimization. The time dependent function of the selected risk measure is obtained from probabilistic safety assessment, i.e. the fault tree analysis at the system level and the fault tree/event tree analysis at the plant level, both extended with inclusion of time requirements. Results of several examples showed that it is possible to reduce risk by application of the proposed method. Because of large uncertainties in the probabilistic safety assessment, the most important result of the method may not be a selection of the most suitable schedule of safety equipment outages among those, which results in similarly low risk. But, it may be a prevention of such schedules of safety equipment outages, which result in high risk. Such finding increases the importance of evaluation speed versus the requirement of getting always the global optimum no matter if it is only slightly better that certain local one

  17. Evaluation of radiological safety conditions of panoramic portable irradiators of industrial radiography used in Brazil

    International Nuclear Information System (INIS)

    Aquino, Josilto Oliveira de

    2003-08-01

    In Brazil, the applications of ionizing radiation in industrial area are performed in about 900 installations, in which around 3000 radioactive sources are handled. Industrial radiography represents 14 % of this total, with 217 X rays equipment and 287 gamma radiography apparatus, according to a survey conducted in the present work. From these gamma apparatus, 90 % employ 192 Ir sources, followed by 60 Co and 75 Se, with 5 % each. The great majority of the 192 Ir apparatus have been in continuous usage in Brazil for more than 20 years, which means that they are old equipment. The totality of the 11 models of 192 Ir apparatus used in Brazil is imported from abroad. Those apparatus are portable, and almost all operate according to category II, i.e., the source assembly is mechanically projected out of the container. This last characteristic, besides the fact that the apparatus are already old-fashioned and worn-out, raises concerns about their radiological safety. The main objective of this work was to develop a specific methodology for inspection, testing and assessment of the radiological safety devices and state of maintenance of the 192 Ir apparatus. The idea is to prevent accidents, as physical failures can lead to overexposure of working staffs. In order to accomplish this, almost a hundred 192 Ir apparatus, from the 11 models used in Brazil, were studied. According to our results, almost 20 % of the 97 apparatus evaluated presented some kind of unsafe condition for proper operation, like poor state of maintenance and faults at the lock that retains the source at the secure position. From the 11 imported models of 192 Ir apparatus in use in Brazil, six models were already manufactured incorporating the safety devices specified by the first edition of the Standard ISO 3999, edited in 1977. However, five models do not comply even with this first edition of the Standard ISO 3999. Thus, they lack some important and basic safety devices. None of the 11 models comply

  18. Evolution of the nondestructive testing equipment for neutron radiography in the framework of the programs of the Services des Piles de Saclay

    International Nuclear Information System (INIS)

    1980-10-01

    The progress made in neutron radiography testing equipment is made with respect to (a) the devices located inside reactor ponds (collimation, leak-tightness, irradiation devices, detection systems), (b) neutron radiography of active parts outside the reactor ponds (testing of fuel rods several metres long by a neutron radiography system by dry feed through), (3) neutron radiography on inactive materials (fitting an axial channel and a side channel in the Triton reactor), (4) neutron radiography on a neutron guide set up at the end of the Neutron Guide Hall associated with the Orphee reactor, i.e. 70 metres from it [fr

  19. Accidents in industrial radiography and lessons to be learned. A review of IAEA Safety Report

    International Nuclear Information System (INIS)

    Modupe, M.S.; Oresegun, O.

    1998-01-01

    This IAEA Safety Report Series publication is the result of a review of a large selection of accidents in industrial radiography which Regulatory Authorities, professional associations and scientific journals have reported. The review's objective was to draw lessons from the initiating events of the accidents, contributing factors and the consequences. A small, representative selection of accident descriptions is used to illustrate the primary causes of radiography accidents and a set of recommendations to prevent recurrence of such accidents or to mitigate the consequences of those that do occur is provided. By far the most common primary cause of over-exposure was 'Failure to follow operational procedures' and specifically failure to perform radiation monitoring to locate the position of the source. The information in the Safety Report is intended for use by Regulatory Authorities, operating organizations, workers manufacturers and client organizations having responsibilities for radiation protection and safety in industrial radiography. (author)

  20. Radiation protection, safety and associated problems in industrial radiography

    International Nuclear Information System (INIS)

    Le Roux, P.R.

    1990-01-01

    Industrial radiography is an indispensable tool for non-destructive testing. Its use entails potential radiation exposure to the operator as well as to the public. Since such radiation has the potential to be harmful, there is a need to limit radiation exposure to a level at which the risk is believed to be acceptable to the individual and to society. The Radiation Protection Society and the Department of National Health believe that the level of protection provided for radiation workers should be comparable with that in other 'safe' industries. The total risk for radiation workers includes the risk of non-radiation related accidents in the various occupations, as well as the special risks of radiation exposure. Industrial radiographers have one of the poorest safety records of all non-medical radiation workers. Operator errors and management errors seem to be the primary contributors to most accidental high exposures. It is necessary to remember that industrial radiography has to be carried out in a wide variety of work places under many different working conditions, both by day and by night. High energy end emissivity (X-ray output or source activity) is required for the radiation to be transmitted through specimens, because these are normally constructed of thick and dense materials such as steel. Additionally, most radiographic sources must be portable to permit use in field locations. On the negative side it must be mentioned that studies undertaken abroad conclude that the most important factors contributing to unsafe operations are human related. Careful planning of the method of work is essential if unnecessary risks are to be avoided. The most effective way of reducing accidents would seem to be to train employees to adhere to established and well documented procedures, to exercise common sense and sound judgement, and to use the protective equipment and devices provided in the manner specified. 2 tabs., 3 refs

  1. Military radiography

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Historic military uses of radiography are discussed in this chapter: Battle of Adowa in 1986 was the first. Besides describing the early campaigns in which radiography was used, the author discusses the problems faced: a reliable source of electricity; the problems of extreme heat; moving and breakage of equipment. Numerous historical photographs are included. 9 refs

  2. Digital radiography in space.

    Science.gov (United States)

    Hart, Rob; Campbell, Mark R

    2002-06-01

    With the permanent habitation of the International Space Station, the planning of longer duration exploration missions, and the possibility of space tourism, it is likely that digital radiography will be needed in the future to support medical care in space. Ultrasound is currently the medical imaging modality of choice for spaceflight. Digital radiography in space is limited because of prohibitive launch costs (in the region of $20,000/kg) that severely restrict the volume, weight, and power requirements of medical care hardware. Technological increases in radiography, a predicted ten-fold decrease in future launch costs, and an increasing clinical need for definitive medical care in space will drive efforts to expand the ability to provide medical care in space including diagnostic imaging. Normal physiological responses to microgravity, in conjunction with the high-risk environment of spaceflight, increase the risk of injury and could imply an extended recovery period for common injuries. The advantages of gravity on Earth, such as the stabilization of patients undergoing radiography and the drainage of fluids, which provide radiographic contrast, are unavailable in space. This creates significant difficulties in patient immobilization and radiographic positioning. Gravity-dependent radiological signs, such as lipohemarthrosis in knee and shoulder trauma, air or fluid levels in pneumoperitoneum, pleural effusion, or bowel obstruction, and the apical pleural edge in pneumothorax become unavailable. Impaired healing processes such as delayed callus formation following fracture will have implications on imaging, and recovery time lines are unknown. The confined nature of spacecraft and the economic impossibility of launching lead-based personal protective equipment present significant challenges to crew radiation safety. A modified, free-floating radiographic C-arm device equipped with a digital detector and utilizing teleradiology support is proposed as a

  3. Procurement strategic analysis of nuclear safety equipment

    International Nuclear Information System (INIS)

    Wu Caixia; Yang Haifeng; Li Xiaoyang; Li Shixin

    2013-01-01

    The nuclear power development plan in China puts forward a challenge on procurement of nuclear safety equipment. Based on the characteristics of the procurement of nuclear safety equipment, requirements are raised for procurement process, including further clarification of equipment technical specification, establishment and improvement of the expert database of the nuclear power industry, adoption of more reasonable evaluation method and establishment of a unified platform for nuclear power plants to procure nuclear safety equipment. This paper makes recommendation of procurement strategy for nuclear power production enterprises from following aspects, making a plan of procurement progress, dividing procurement packages rationally, establishing supplier database through qualification review and implementing classified management, promoting localization process of key equipment continually and further improving the system and mechanism of procurement of nuclear safety equipment. (authors)

  4. 49 CFR 238.230 - Safety appliances-new equipment.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Safety appliances-new equipment. 238.230 Section... I Passenger Equipment § 238.230 Safety appliances—new equipment. (a) Applicability. This section..., 2007, that is equipped with a safety appliance, required by the “manner of application” provisions in...

  5. Implementation of the safety assessment in the practice of industrial radiography

    International Nuclear Information System (INIS)

    Alfonso Pallarés, C.; Pérez Reyes, Y.

    2015-01-01

    The CNSN as regulatory authority has regulatory control processes based on regulations, permits, inspections and limitation to ensure the supervision and control of the practice of industrial radiography. On the other hand in the light of the new regulations approved and being implemented such as: Resolution 334/2011 CITMA 'Regulation on Notification and authorization of practices and activities associated with the use of ionizing radiation sources' and Resolution 17 / 2012, Security Guide: Security Assessment Practices and Activities associated with the use of ionizing radiation (recommendatory), it is necessary for compliance with regulatory requirements concerning the safety assessment. Since 2009 it has been applied this experience in different medical practices and industry, providing a systematic and consistent basis, to the safety assessment of all facilities and activities, which has helped increase the confidence that has been achieved an adequate level of security. The work was able to identify that there is a group of barriers operating in the risk reduction in various accident sequences and therefore have a relative importance in risk reduction, recommendations in this regard to improve the program management of safety in the practice of industrial radiography. [es

  6. Assessment of the Main Deviations Found during Regulatory Inspections in Industrial Gamma Radiography in Argentina

    International Nuclear Information System (INIS)

    Alonso Jimenez, M.T.; Ermacora, M.G.

    2011-01-01

    The present paper shows the regulatory work made through inspections concerning radiation safety and security in the area of industrial gamma radiography. An account is shown of the items which should be available in the storage facility where the equipment and radioactive sources are placed as well as in site radiography and which are required to the users of the equipment meant for this practice, in order to ensure compliance with the regulations in force. The objective of this paper is to assess the most frequent deviations to the regulatory standards found during this type of inspections, such as lack of complete and operable radiation protection equipment, lack of available elements bound to act in case of emergency, no delimitation of controlled areas, gamma radiography equipment stored in unlocked position, wear gauge unavailable, record of movements of equipment and radioactive sources not updated, anomalous monthly or annual personal dose values, among the main findings. In particular, in connection with dose reports, some cases of occupational exposed workers exceeding the annual dose limits or investigation levels are highlighted. In addition, the explanations provided by the person responsible for radiation protection of companies in regard to the possible causes or circumstances which might have given rise to such dose values, the conclusions reached and the preventive and corrective measures implemented by these companies are analysed. Finally, an assessment of the annual dose distributions of the occupational exposed workers concerned with this kind of practice in the period 2004-2007 is shown. As a conclusion, the relevance of these deviations according to degradation in safety and security performance and the role of the regulatory work as a promoter of the implementation of safety culture will be emphasized. (authors)

  7. Assessment of the main deviations found during regulatory inspections in industrial gamma radiography in Argentina

    International Nuclear Information System (INIS)

    Alonso Jimenez, Maria T.; Ermacora, Marcela

    2008-01-01

    The present paper shows the regulatory work made through inspections concerning radiation safety and security in the area of industrial gamma radiography. An account is shown of the items which should be available in the storage facility where the equipment and radioactive sources are placed as well as in site radiography and which are required to the users of the equipment meant for this practice, in order to ensure compliance with the regulations in force. The objective of this paper is to assess the most frequent deviations to the regulatory standards found during this type of inspections, such as lack of complete and operable radiation protection equipment, lack of available elements bound to act in case of emergency, no delimitation of controlled areas, gamma radiography equipment stored in unlocked position, wear gauge unavailable, record of movements of equipment and radioactive sources not updated, anomalous monthly or annual personal dose values, among the main findings. In particular, in connection with dose reports, some cases of occupational exposed workers exceeding the annual dose limits or investigation levels are highlighted. In addition, the explanations provided by the person responsible for radiation protection of companies in regard to the possible causes or circumstances which might have given rise to such dose values, the conclusions reached and the preventive and corrective measures implemented by these companies are analysed. Finally, an assessment of the annual dose distributions of the occupational exposed workers concerned with this kind of practice in the period 2004-2007 is shown. As a conclusion, the relevance of these deviations according to degradation in safety and security performance and the role of the regulatory work as a promoter of the implementation of safety culture will be emphasized. (author)

  8. Analysis of the spatial rates dose rates during dental panoramic radiography

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Jong Kyung [Dept. of Radiation Safety Management Commission, Daegu Health College, Daegu (Korea, Republic of); Park, Myeong Hwan [Dept. of Radiologic Technology, Daegu Health College, Daegu (Korea, Republic of); Kim, Yong Min [Dept. of Radiological Science, Catholic University of Daegu, Daegu (Korea, Republic of)

    2016-12-15

    A dental panoramic radiography which usually uses low level X-rays is subject to the Nuclear Safety Act when it is installed for the purpose of education. This paper measures radiation dose and spatial dose rate by usage and thereby aims to verify the effectiveness of radiation safety equipment and provide basic information for radiation safety of radiation workers and students. After glass dosimeter (GD-352M) is attached to direct exposure area, the teeth, and indirect exposure area, the eye lens and the thyroid, on the dental radiography head phantom, these exposure areas are measured. Then, after dividing the horizontal into a 45°, it is separated into seven directions which all includes 30, 60, 90, 120 cm distance. The paper shows that the spatial dose rate is the highest at 30 cm and declines as the distance increases. At 30 cm, the spatial dose rate around the starting area of rotation is 3,840 μSv/h, which is four times higher than the lowest level 778 μSv/h. Furthermore, the spatial dose rate was 408 μSv/h on average at the distance of 60 cm where radiation workers can be located. From a conservative point of view, It is possible to avoid needless exposure to radiation for the purpose of education. However, in case that an unintended exposure to radiation happens within a radiation controlled area, it is still necessary to educate radiation safety. But according to the current Medical Service Act, in medical institutions, even if they are not installed, the equipment such as interlock are obliged by the Nuclear Safety Law, considering that the spatial dose rate of the educational dental panoramic radiography room is low. It seems to be excessive regulation.

  9. Order of 2 May 1977 on a proficiency certificate for handling industrial radioscopy and radiography equipment

    International Nuclear Information System (INIS)

    1977-01-01

    This Order lays down that any person handling industrial radioscopy or radiography equipment must obtain a proficiency certificate delivered by a regional jury made up of the regional director for labour and manpower or his representative, a physician competent for industrial medicine and specialized in radiation protection and an expert in industrial radiology. (NEA) [fr

  10. Safety and security of radioactive sources in industrial radiography in Bangladesh

    Energy Technology Data Exchange (ETDEWEB)

    Mollah, A. S.; Nazrul, M. Abdullah [Industrial Inspection Service Limited, Dhaka (Bangladesh)

    2013-07-01

    Malicious use of radioactive sources can involve dispersal of that material through an explosive device. There has been recognition of the threat posed by the potential malicious misuse of NDT radioactive source by terrorists. The dispersal of radioactive material using conventional explosives, referred to as a 'dirty bomb', could create considerable panic, disruption and area access denial in an urban environment. However, as it is still a relatively new topic among regulators, users, and transport and storage operators worldwide, international assistance and cooperation in developing the necessary regulatory and security infrastructure is required. The most important action in reducing the risk of radiological terrorism is to increase the security of radioactive sources. This paper presents safety and security considerations for the transport and site storage of the industrial radiography sources as per national regulations entitled 'Nuclear Safety and Radiation Control Rules-1997'.The main emphasis was put on the stages of some safety and security actions in order to prevent theft, sabotage or other malicious acts during the transport of the packages. As a conclusion it must be mentioned that both safety and security considerations are very important aspects that must be taking in account for the transport and site storage of radioactive sources used in the practice of industrial radiography. (authors)

  11. Safety and security of radioactive sources in industrial radiography in Bangladesh

    International Nuclear Information System (INIS)

    Mollah, A. S.; Nazrul, M. Abdullah

    2013-01-01

    Malicious use of radioactive sources can involve dispersal of that material through an explosive device. There has been recognition of the threat posed by the potential malicious misuse of NDT radioactive source by terrorists. The dispersal of radioactive material using conventional explosives, referred to as a 'dirty bomb', could create considerable panic, disruption and area access denial in an urban environment. However, as it is still a relatively new topic among regulators, users, and transport and storage operators worldwide, international assistance and cooperation in developing the necessary regulatory and security infrastructure is required. The most important action in reducing the risk of radiological terrorism is to increase the security of radioactive sources. This paper presents safety and security considerations for the transport and site storage of the industrial radiography sources as per national regulations entitled 'Nuclear Safety and Radiation Control Rules-1997'.The main emphasis was put on the stages of some safety and security actions in order to prevent theft, sabotage or other malicious acts during the transport of the packages. As a conclusion it must be mentioned that both safety and security considerations are very important aspects that must be taking in account for the transport and site storage of radioactive sources used in the practice of industrial radiography. (authors)

  12. Radiographic Co-60 in component of heavy equipment casting

    International Nuclear Information System (INIS)

    Djoli Soembogo, Harun Al Rasyid R dan Namad Sianta

    2016-01-01

    The application of radiography using isotope Co-60 source has been used on component of heavy equipment such as component of heavy equipment casting. Components of heavy equipment casting made through metal casting of carbon steel. This study tried applying digital radiography are using isotope Co-60 sources and using scanning positive film media of Epson V700 for digitization results of conventional radiographic films. This radiography is using film AGFA D7 and Fuji 100 to obtain a contrast medium, medium sensitivity and image quality is good. The purpose radiographic Co-60 at a component of heavy equipment casting is detecting indications of the shape and type casting defects of component of heavy equipment casting thus fit for use. Radiographic test of Co-60 has been carried out on component of heavy equipment casting with single wall single image method and the results of radiographic films digitization using scanning positive film media of Epson V700 with observation parameters casting defects. Time exposure of Co-60 radiation was 10 and 15 minutes hours for metal castings of carbon steel for thickness 20.00-50.00 mm by using activity 30.05 Ci and the perpendicular distance to the source of the film is 820 mm. Scanner positive film results in the form of digital radiography which allow for the transfer of digital data or digital computerized data storage. Radiographic test results on component of heavy equipment casting with single wall single image method produce the parameter casting defect of component of heavy equipment casting in position of critical area is found shrinkage that should be repaired and in position of safety area is not found defect indication so casting defect of component of heavy equipment casting are not acceptable according to standards referenced. (author)

  13. Functioning of industrial radiography services

    International Nuclear Information System (INIS)

    Alves, R.N.; Costa, H.M. da; Bianchini, F.G.; Arrieta, L.A.I.

    1988-12-01

    The objective of this norm is establish the necessary requirements for the functioning of industrial radiography services, as well as the procedures for acquisition and transfer of radioactive sources and/or X-ray equipments used in industrial radiography [pt

  14. National data analysis of general radiography projection method in medical imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Su; Seo, Deok Nam; Choi, In Seok [Dept. of Bio-Convergence Engineering, Korea University Graduate School, Seoul (Korea, Republic of); and others

    2014-09-15

    According to database of medical institutions of health insurance review and assessment service in 2013, 1,118 hospitals and clinics have department of radiology in Korea. And there are CT, fluoroscopic and general radiographic equipment in those hospitals. Above all, general radiographic equipment is the most commonly used in the radiology department. And most of the general radiographic equipment are changing the digital radiography system from the film-screen types of the radiography system nowadays. However, most of the digital radiography department are used the film-screen types of the radiography system. Therefore, in this study, we confirmed present conditions of technical items for general radiography used in hospital and research on general radiographic techniques in domestic medical institutions. We analyzed 26 radiography projection method including chest, skull, spine and pelvis which are generally used in the radiography department.

  15. Dental radiography

    International Nuclear Information System (INIS)

    Shekhdar, J.

    1993-01-01

    Dental radiography must comply with the same regulations with which conventional radiography complies. Radiation doses to individual patients are low but, because of the large number of patients X-rayed, the collective dose to the population is not negligible. Care in siting and regular maintenance of the equipment will reduce doses to both staff and patients. To produce X-ray films with a good image quality using a low radiation dose requires attention to film processing; this is often a neglected area. (Author)

  16. Plutonium finishing plant safety systems and equipment list

    International Nuclear Information System (INIS)

    Bergquist, G.G.

    1995-01-01

    The Safety Equipment List (SEL) supports Analysis Report (FSAR), WHC-SD-CP-SAR-021 and the Plutonium Finishing Plant Operational Safety Requirements (OSRs), WHC-SD-CP-OSR-010. The SEL is a breakdown and classification of all Safety Class 1, 2, and 3 equipment, components, or system at the Plutonium Finishing Plant complex

  17. New radiation protection concept as important safety factor of industrial radiography

    International Nuclear Information System (INIS)

    Pavlovic, R.; Pavlovic, S.

    1998-01-01

    Industrial radiography is a method for non destructive testing of homogeneity of various materials based on different absorption of radiation in different material. X and γ radiation are the most often used. Detrimental effects of radiation are observed since its discovery. In order to prevent harmful effects of radiation without unduly limitations of its use, International Commission on Radiological Protection in collaboration with International Atomic Energy Agency have developed International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources, Safety Series No 115, adopted in 1996. based on ICRP recommendations from 1991. Besides a lot of changes in radiation protection concept and philosophy, decrement of annual dose limits for occupational exposure from 50 to 20 mSv. (author)

  18. Radiation safety aspects in application of isotopes for industrial radiography in Bangladesh

    Energy Technology Data Exchange (ETDEWEB)

    Bakht, D. [Titas Gas Transmission and Distribution Company, Dhaka (Bangladesh)

    1997-10-01

    Industrial Radiography arose out of the widespread applications of X-rays pioneered by Roentgen about 100 years back. It is routinely used in studying the integrity of structural materials and like most countries in the world, its use in Bangladesh is increasing at a faster rate. This is because Bangladesh is a developing country of 3rd world and in the backdrop of agrarian poverty ridden economy, its population may exceed 125 millions by 2000 AD, leaving some 12 millions people unemployed. To support them, therefore, immense activities are activated in different sectors. Accordingly, increasing importance on NDT is given and in most cases particular application of Gamma radiography is preferred using Iridium Isotope Ir-192. Consequently the points of implications of isotopes are in Open Field and Inservice Inspection Radiography, Handling of Radiation Emergencies, Safe Transport of Radioactive Materials and Hazardous Effects and Risk of Ionizing Radiation, etc. Accordingly over exposure of Ir-192 Radionuclides, Accidents and Unusual Occurrences: Case Studies, Training Courses on Safety and Regulation of Sealed Sources, Licenses for Radiography Operation including Safe Disposal of Isotopes are the salient issues to be viewed in appropriate perspectives. The role played by Bangladesh Atomic Energy Commission and Bangladesh Society for NDT in collaboration with other members of the international committee for NDT are furthering the safe industrialization process

  19. Radiation safety aspects in application of isotopes for industrial radiography in Bangladesh

    International Nuclear Information System (INIS)

    Bakht, D.

    1997-01-01

    Industrial Radiography arose out of the widespread applications of X-rays pioneered by Roentgen about 100 years back. It is routinely used in studying the integrity of structural materials and like most countries in the world, its use in Bangladesh is increasing at a faster rate. This is because Bangladesh is a developing country of 3rd world and in the backdrop of agrarian poverty ridden economy, its population may exceed 125 millions by 2000 AD, leaving some 12 millions people unemployed. To support them, therefore, immense activities are activated in different sectors. Accordingly, increasing importance on NDT is given and in most cases particular application of Gamma radiography is preferred using Iridium Isotope Ir-192. Consequently the points of implications of isotopes are in Open Field and Inservice Inspection Radiography, Handling of Radiation Emergencies, Safe Transport of Radioactive Materials and Hazardous Effects and Risk of Ionizing Radiation, etc. Accordingly over exposure of Ir-192 Radionuclides, Accidents and Unusual Occurrences: Case Studies, Training Courses on Safety and Regulation of Sealed Sources, Licenses for Radiography Operation including Safe Disposal of Isotopes are the salient issues to be viewed in appropriate perspectives. The role played by Bangladesh Atomic Energy Commission and Bangladesh Society for NDT in collaboration with other members of the international committee for NDT are furthering the safe industrialization process

  20. Establishing local rules for industrial radiography practice using radionuclides

    International Nuclear Information System (INIS)

    Ambrosio, N.

    2012-04-01

    Industrial Radiograph used for non-destructive testing of material or equipment constitutes one of the most important applications of radiation sources. Non-destructive testing (NDT) provides a means of verifying the physical integrity of equipment and structures such as vessels, pipes, welded joints, castings and other devices. The physical integrity of such equipment and structures affects not only the safety and quality of the products but also the protection of workers, the public and the environment, as operator of these devises could result in accidents. The development and maintenance of safety culture in an operating organization has to cover management systems, policies, responsibilities, procedures and organizational arrangements.The essence is to control radiation hazard, optimize radiation protection to prevent or reduce exposures and mitigate the consequences of accidents and incidents. To achieve high degree of professionalism, appropriate national and organizational infrastructure is required in addition to ensure effective training of workers, compliance with safety culture and effective quality control. Therefore, this report presents a model Local Rules and procedures necessary for the safe operation of Industrial Radiography devises in order to protect worker, the public and the environment. The model has been developed from examples from published reports. (author)

  1. Workshop on industrial isotope radiography: Programme and lectures

    International Nuclear Information System (INIS)

    1979-01-01

    The booklet contains the texts of lectures delivered in the Workshop on Industrial Radiography held at Bombay during 24-25 July 1979. The lectures cover some topics of relevance to industrial radiography. The topics are radiation protection and legislative aspects in industrial radiography; problems in field radiography in fertilizer industry, petrochemical industry and heavy engineering industry; occupational exposures in industrial radiography; and a review of the progress and recent trends in industrial radiographic techniques and equipment. (M.G.B.)

  2. The level of knowledge and radiation safety practice amongst cardiovascular technology, medical assistant, nursing and diagnostic radiography students and dose monitoring in radiography laboratory of Kolej Islam Sains dan Teknologi, Kelantan

    International Nuclear Information System (INIS)

    Ainul Fadhlin Othman; Amran Abdul Majid

    2013-01-01

    Full-text: This study investigated the knowledge level and practices regarding radiation safety among the cardiovascular technology, medical assistant nursing and radiography diagnostic students of Kolej Islam Sains dan Teknologi (KIST). The objectives of this study are to monitor the dose rate at radiography lab and to propose the guideline on radiation safety topics to improve the syllabus. 274 respondents including 30 psychology students acting as the control group were asked to answer questions from the questionnaires which cover the topics of basic knowledge of radiation and radiation safety practice. There was a significant difference (p < 0.05) between the correct answers and courses for 18 questions except for the question 4. There was a significant different (p < 0.05) between the correct answers and year of study for the questions 4, 5, 7, 12 to 15 and 18 to 20. There was a significance different (p < 0.05) between the correct answers and gender for questions 7, 11 and 19. For area dose monitoring in the radiography diagnostic lab, the assessment report on film batches of 4 walls in the lab were recorded and Victoreen451-RYR survey meter was used to monitor the dose rate for 7 selected areas with the exposure factors set for the chest, abdomen, upper extremity, lower extremity and skull radiography examinations. The dose rates at area 1 to 4, area 5 during the examination of chest, abdomen and skull, area 6 during the examination of abdomen and area 7 during the examination of abdomen, had exceeded the dose limit for radiation worker. The dose rate at the area 1 and 4 are slightly higher than the other areas. The contributing factors are the distance, tube potential, collimation and X-ray tube angulation. This study had shown that the cardiovascular technology and diagnostic radiography students have better knowledge and radiation safety practice level than the medical assistant and nursing students. In general, the level of knowledge and radiation safety

  3. Direct magnification radiography of newborn with mobile X-ray equipment

    International Nuclear Information System (INIS)

    Fukai, Kazuhiko; Kigure, Hatsuo; Hatori, Noboru; Shinohara, Yasuji.

    1989-01-01

    Small patient size is a major factor of the difficulty in interpreting the newborn infant radiograph. Direct radiographic magnification can be employed to relieve this problem and special positioning devices were made to image the infant, confined to incubator and connected to life-supporting systems. The mobile X-ray equipment with a microfocus (0.2 mm) radiographic tube, a rare-earth high-speed recording system and carbon cassette were combined to obtain a radiograph at magnification of 1.5-2.0. Image quality was superior to that of conventional contact radiographic system, but infant radiation exposure was 26% more than that of conventional study. Although direct radiographic magnification was very useful to recognize subtle or equivocal abnormality which could not be made from conventional image, its application should be restricted to specific disease at this present, considering infant radiation exposures. This technique will have wide clinical application when radiation exposure can be reduced by using other recording system such as computed radiography (CR). (author)

  4. Better imaging: the advantages of digital radiography

    NARCIS (Netherlands)

    van der Stelt, P.F.

    2008-01-01

    Background. Digital radiography has been available in dentistry for more than 25 years, but it has not replaced conventional film-based radiography completely. This could be because of the costs involved in replacing conventional radiographic equipment with a digital imaging system, or because

  5. Safety guide of safe use of industrial radiography

    International Nuclear Information System (INIS)

    1994-01-01

    The objective of this guidance is to present general regulations for the safe use and radiation protection of industrial radiography. Storage and inspection of apparatus, personal instructions for working in radiography facilities are offered

  6. Safety management of software-based equipment

    CERN Document Server

    Boulanger, Jean-Louis

    2013-01-01

    A review of the principles of the safety of software-based equipment, this book begins by presenting the definition principles of safety objectives. It then moves on to show how it is possible to define a safety architecture (including redundancy, diversification, error-detection techniques) on the basis of safety objectives and how to identify objectives related to software programs. From software objectives, the authors present the different safety techniques (fault detection, redundancy and quality control). "Certifiable system" aspects are taken into account throughout the book. C

  7. Filmless radiography - present possibilities and direction of future developing

    International Nuclear Information System (INIS)

    Wocial, A.; Wojciechowski, Z.A.; Rozenblicki, Z.

    2008-01-01

    The paper presents introduction for new filmless radiography like CR Computed Radiography and DR Digital Radiography direct and non direct. The main factors are considered, which determine classification to different type of radiography. For each technique authors describe advantages and disadvantages supporting by practice examples. Paper contains a lot of practical information about a most of existing radiographic equipment at the NDT market. (author)

  8. Studies on the radiation exposure and protection at the X-ray radiography in the medical care at home

    International Nuclear Information System (INIS)

    Suzuki, Shoichi; Fujii, Shigehisa; Asada, Yasuo; Orito, Takeo; Kamei, Tetsuya; Koga, Sukehiko

    1998-01-01

    Since there are scarce studies on the exposure and protection at the radiography in the medical care at home, authors performed such studies as comparison of doses from self-rectifying and inverter tubes, exposure and protection to patients and nursing persons and actual measurement (October, 1997) at home in Tohno city, Iwate prefecture, of scattering radiation dose at radiography. Apparatuses used were: Portable X-ray equipments; self-rectifying types (Toshiba TR-20 and Medisonacoma PX 30N) and an inverter type (Medisonacoma PX-15HF), Kyoto Kagaku WAC water phantom, X-ray analyzer Model 200 of Kasei Optonics, and Dosimeters (Victoreen Radocon ionization dosimeter and Aloka ICS-301 ionization chamber survey meters). Radiation qualities, surface doses and scattering doses of the equipments under various conditions were compared by the half value layer and effective energy measured with the analyzer. Actual measurement of scattering dose was done at home for 4 patients at chest radiography. Annual dose in monthly ordinary radiography at home, when the distance was >200 cm far from the flux center, was found about 1/100 of 1 mSv (the annual public dose limit), thus securing the safety of nurses. (K.H.)

  9. Studies on the radiation exposure and protection at the X-ray radiography in the medical care at home

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Shoichi; Fujii, Shigehisa; Asada, Yasuo; Orito, Takeo [Fujita Health Univ., Toyoake, Aichi (Japan). School of Health Science; Kamei, Tetsuya; Koga, Sukehiko

    1998-12-01

    Since there are scarce studies on the exposure and protection at the radiography in the medical care at home, authors performed such studies as comparison of doses from self-rectifying and inverter tubes, exposure and protection to patients and nursing persons and actual measurement (October, 1997) at home in Tohno city, Iwate prefecture, of scattering radiation dose at radiography. Apparatuses used were: Portable X-ray equipments; self-rectifying types (Toshiba TR-20 and Medisonacoma PX 30N) and an inverter type (Medisonacoma PX-15HF), Kyoto Kagaku WAC water phantom, X-ray analyzer Model 200 of Kasei Optonics, and Dosimeters (Victoreen Radocon ionization dosimeter and Aloka ICS-301 ionization chamber survey meters). Radiation qualities, surface doses and scattering doses of the equipments under various conditions were compared by the half value layer and effective energy measured with the analyzer. Actual measurement of scattering dose was done at home for 4 patients at chest radiography. Annual dose in monthly ordinary radiography at home, when the distance was >200 cm far from the flux center, was found about 1/100 of 1 mSv (the annual public dose limit), thus securing the safety of nurses. (K.H.)

  10. Guidelines for nuclear reactor equipments safety-analysis

    International Nuclear Information System (INIS)

    1978-01-01

    The safety analysis in approving the applications for nuclear reactor constructions (or alterations) is performed by the Committee on Examination of Reactor Safety in accordance with various guidelines prescribed by the Atomic Energy Commission. In addition, the above Committee set forth its own regulations for the safety analysis on common problems among various types of nuclear reactors. This book has collected and edited those guidelines and regulations. It has two parts: Part I includes the guidelines issued to date by the Atomic Energy Commission: and Part II - regulations of the Committee. Part I has collected 8 categories of guidelines which relate to following matters: nuclear reactor sites analysis guidelines and standards for their applications; standard exposure dose of plutonium; nuclear ship operation guidelines; safety design analysis guidelines for light-water type, electricity generating nuclear reactor equipments; safety evaluation guidelines for emergency reactor core cooling system of light-water type power reactors; guidelines for exposure dose target values around light-water type electricity generating nuclear reactor equipments, and guidelines for evaluation of above target values; and meteorological guidelines for the safety analysis of electricity generating nuclear reactor equipments. Part II includes regulations of the Committee concerning - the fuel assembly used in boiling-water type and in pressurized-water type reactors; techniques of reactor core heat designs, etc. in boiling-water reactors; and others

  11. 30 CFR 250.806 - Safety and pollution prevention equipment quality assurance requirements.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Safety and pollution prevention equipment... Gas Production Safety Systems § 250.806 Safety and pollution prevention equipment quality assurance... install only certified safety and pollution prevention equipment (SPPE) in wells located on the OCS. SPPE...

  12. The industrial radiography of defects inside the European Community

    International Nuclear Information System (INIS)

    Roeper, Burkhardt; Kaempf, B.

    1976-03-01

    The concept of the industrial radiography applied to defect invesigation is defined. The following topics are successively discussed: the development of the industrial 'defect radiography', apparatus and auxiliary equipments used in the field, the market, the constructors, trade currents in 'defect radiography' inside the Community and in the outer market; prognostics on future requirements in the fields

  13. 46 CFR 189.60-10 - Cargo Ship Safety Equipment Certificate.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Cargo Ship Safety Equipment Certificate. 189.60-10... VESSELS INSPECTION AND CERTIFICATION Certificates Under International Convention for Safety of Life at Sea, 1974 § 189.60-10 Cargo Ship Safety Equipment Certificate. (a) All vessels on an international voyage...

  14. 46 CFR 91.60-10 - Cargo Ship Safety Equipment Certificate.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Cargo Ship Safety Equipment Certificate. 91.60-10... VESSELS INSPECTION AND CERTIFICATION Certificates Under International Convention for Safety of Life at Sea, 1974 § 91.60-10 Cargo Ship Safety Equipment Certificate. (a) All vessels on an international voyage are...

  15. Evaluation of the Radiological Safety of 192 Ir Apparatus for Industrial Gamma Radiography

    International Nuclear Information System (INIS)

    Aquino, J. O.; Silva, F. C. A. da; Ramalho, A. T.; Godoy, J. M. O.

    2004-01-01

    The majority of the 192Ir apparatus for industrial gamma radiography have been in usage in Brazil for more than 20 years. They are portable, and almost all operate according to category II. The main objective of this work was to assess the radiological safety of the 11 models of 192Ir apparatus most used in Brazil. The 11 models of 192Ir apparatus were studied with respect to compliance with the main safety requirements of three editions of international Standards ISO 3999. Six models were already manufactured incorporating the safety devices specified in the first edition of ISO 3999, issued in 1977. However, five models were not. The validity of their type B certificates for transport packages was also evaluated. (Author) 8 refs

  16. Real-time radiography

    International Nuclear Information System (INIS)

    Bossi, R.H.; Oien, C.T.

    1981-01-01

    Real-time radiography is used for imaging both dynamic events and static objects. Fluorescent screens play an important role in converting radiation to light, which is then observed directly or intensified and detected. The radiographic parameters for real-time radiography are similar to conventional film radiography with special emphasis on statistics and magnification. Direct-viewing fluoroscopy uses the human eye as a detector of fluorescent screen light or the light from an intensifier. Remote-viewing systems replace the human observer with a television camera. The remote-viewing systems have many advantages over the direct-viewing conditions such as safety, image enhancement, and the capability to produce permanent records. This report reviews real-time imaging system parameters and components

  17. Artifacts in digital radiography

    International Nuclear Information System (INIS)

    Min, Jung Whan; Kim, Jung Min; Jeong, Hoi Woun

    2015-01-01

    Digital Radiography is a big part of diagnostic radiology. Because uncorrected digital radiography image supported false effect of Patient’s health care. We must be manage the correct digital radiography image. Thus, the artifact images can have effect to make a wrong diagnosis. We report types of occurrence by analyzing the artifacts that occurs in digital radiography system. We had collected the artifacts occurred in digital radiography system of general hospital from 2007 to 2014. The collected data had analyzed and then had categorize as the occurred causes. The artifacts could be categorized by hardware artifacts, software artifacts, operating errors, system artifacts, and others. Hardware artifact from a Ghost artifact that is caused by lag effect occurred most frequently. The others cases are the artifacts caused by RF noise and foreign body in equipments. Software artifacts are many different types of reasons. The uncorrected processing artifacts and the image processing error artifacts occurred most frequently. Exposure data recognize (EDR) error artifacts, the processing error of commissural line, and etc., the software artifacts were caused by various reasons. Operating artifacts were caused when the user did not have the full understanding of the digital medical image system. System artifacts had appeared the error due to DICOM header information and the compression algorithm. The obvious artifacts should be re-examined, and it could result in increasing the exposure dose of the patient. The unclear artifact leads to a wrong diagnosis and added examination. The ability to correctly determine artifact are required. We have to reduce the artifact occurrences by understanding its characteristic and providing sustainable education as well as the maintenance of the equipments

  18. Artifacts in digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Min, Jung Whan [Dept. of Radiological Technology, Shin Gu University, Sungnam (Korea, Republic of); Kim, Jung Min [Dept. of Radiological Technology, Korea University, Seoul (Korea, Republic of); Jeong, Hoi Woun [Dept. of Radiological Technology, Beakseok Culture University, Cheonan (Korea, Republic of)

    2015-12-15

    Digital Radiography is a big part of diagnostic radiology. Because uncorrected digital radiography image supported false effect of Patient’s health care. We must be manage the correct digital radiography image. Thus, the artifact images can have effect to make a wrong diagnosis. We report types of occurrence by analyzing the artifacts that occurs in digital radiography system. We had collected the artifacts occurred in digital radiography system of general hospital from 2007 to 2014. The collected data had analyzed and then had categorize as the occurred causes. The artifacts could be categorized by hardware artifacts, software artifacts, operating errors, system artifacts, and others. Hardware artifact from a Ghost artifact that is caused by lag effect occurred most frequently. The others cases are the artifacts caused by RF noise and foreign body in equipments. Software artifacts are many different types of reasons. The uncorrected processing artifacts and the image processing error artifacts occurred most frequently. Exposure data recognize (EDR) error artifacts, the processing error of commissural line, and etc., the software artifacts were caused by various reasons. Operating artifacts were caused when the user did not have the full understanding of the digital medical image system. System artifacts had appeared the error due to DICOM header information and the compression algorithm. The obvious artifacts should be re-examined, and it could result in increasing the exposure dose of the patient. The unclear artifact leads to a wrong diagnosis and added examination. The ability to correctly determine artifact are required. We have to reduce the artifact occurrences by understanding its characteristic and providing sustainable education as well as the maintenance of the equipments.

  19. Experience of safety and performance improvement for fuel handling equipment

    International Nuclear Information System (INIS)

    Gyoon Chang, Sang; Hee Lee, Dae

    2014-01-01

    The purpose of this study is to provide experience of safety and performance improvement of fuel handling equipment for nuclear power plants in Korea. The fuel handling equipment, which is used as an important part of critical processes during the refueling outage, has been improved to enhance safety and to optimize fuel handling procedures. Results of data measured during the fuel reloading are incorporated into design changes. The safety and performance improvement for fuel handling equipment could be achieved by simply modifying the components and improving the interlock system. The experience provided in this study can be useful lessons for further improvement of the fuel handling equipment. (authors)

  20. Radiological protection procedures for industrial applications of computed radiography

    International Nuclear Information System (INIS)

    Aquino, Josilto Oliveira de

    2009-03-01

    Due to its very particular characteristics, industrial radiography is responsible for roughly half of the relevant accidents in nuclear industry, in developed as well as in developing countries, according to the International Atomic Energy Agency (IAEA). Thus, safety and radiological protection in industrial gamma radiography have been receiving especial treatment by regulatory authorities of most Member States. The main objective of the present work was to evaluate, from the radioprotection point of view, the main advantages of computed radiography (CR) for filmless industrial radiography. In order to accomplish this, both techniques, i.e. conventional and filmless computed radiography were evaluated and compared through practical studies. After the studies performed at the present work it was concluded that computed radiography significantly reduces the inherent doses, reflecting in smaller restricted areas and costs, with consequent improvement in radiological protection and safety. (author)

  1. Control of Nuclear Materials and Special Equipment (Nuclear Safety Regulations)

    International Nuclear Information System (INIS)

    Cizmek, A.; Prah, M.; Medakovic, S.; Ilijas, B.

    2008-01-01

    Based on Nuclear Safety Act (OG 173/03) the State Office for Nuclear Safety (SONS) in 2008 adopted beside Ordinance on performing nuclear activities (OG 74/06) and Ordinance on special conditions for individual activities to be performed by expert organizations which perform activities in the area of nuclear safety (OG 74/06) the new Ordinance on the control of nuclear material and special equipment (OG 15/08). Ordinance on the control of nuclear material and special equipment lays down the list of nuclear materials and special equipment as well as of nuclear activities covered by the system of control of production of special equipment and non-nuclear material, the procedure for notifying the intention to and filing the application for a license to carry out nuclear activities, and the format and contents of the forms for doing so. This Ordinance also lays down the manner in which nuclear material records have to be kept, the procedure for notifying the State administration organization (regulatory body) responsible for nuclear safety by the nuclear material user, and the keeping of registers of nuclear activities, nuclear material and special equipment by the State administration organization (regulatory body) responsible for nuclear safety, as well as the form and content of official nuclear safety inspector identification card and badge.(author)

  2. Development of tungsten collimators for industrial radiography

    International Nuclear Information System (INIS)

    Varkey, P.A.; Verma, P.B.; Jayakumar, T.K.; Mammachan, M.K.

    2001-01-01

    Collimators are essential components of industrial radiography set up as it provides radiation safety to persons involved in the radiography work. A collimator with optimum design features also helps in reducing the scattered radiation which in turn results in radiographs having better sensitivity. This papers describes the salient design features of the tungsten collimators developed by the BRIT, for industrial radiography. (author)

  3. A Glance on the Safety Culture in Industrial Gamma Radiography in the Philippines: Regulatory Body Perspective

    International Nuclear Information System (INIS)

    Borras, A.M.

    2016-01-01

    The current version of the Code of PNRI Regulations (CPR) Part 11 was published in the Official Gazette on 2010. It is just a year ahead of the publication of the IAEA Specific Safety Guide No. 11. In view of these, radiation safety culture in the practice of industrial gamma radiography was not yet fully introduced in the said national regulations in the country. However, it should not be a reflection that the radiation workers in the country specifically in the said field of practice do not exercise positive safety culture. The Nuclear Regulatory Division (NRD)—regulatory arm, although not yet separated from the Philippine Nuclear Research Institute (PNRI0) as mandated by law — the promotional organization, has a well established and systemic regulatory infrastructure. It is attested by several studies and reports, among others. This study aims to assess the status of the existing safety culture in the conduct of industrial gamma radiography in the country through personnel perception survey of the radiation workers, i.e., managers, radiation safety officers, radiographers and radiographer’s assistants, based on the IAEA five characteristics of safety culture stipulated in the IAEA Safety Guide No. GS-G-3.5, “The Management System for Nuclear Installations”. It is assessed by the NRD of the PNRI. Also, the study determines the existence of safety culture as to the perspective of NRD through observations on the conduct of radiographic operations and walk-through of the facility while using the three-level Schein Model, i.e., “artefacts”, “espoused values” and “basic assumptions” and document reviews, among others

  4. Safety requirements and feedback of commonly used material handling equipment

    International Nuclear Information System (INIS)

    Pathak, M.K.

    2009-01-01

    Different types of cranes, hoists, chain pulley blocks are the most commonly used material handling equipment in industry along with attachments like chains, wire rope slings, d-shackles, etc. These equipment are used at work for transferring loads from one place to another and attachments are used for anchoring, fixing or supporting the load. Selection of the correct equipment, identification of the equipment planning of material handling operation, examination/testing of the equipment, education and training of the persons engaged in operation of the material handling equipment can reduce the risks to safety of people in workplace. Different safety systems like boom angle indicator, overload tripping device, limit switches, etc. should be available in the cranes for their safe use. Safety requirement for safe operation of material handling equipment with emphasis on different cranes and attachments particularly wire rope slings and chain slings have been brought out in this paper. An attempt has also been made to bring out common nature of deficiencies observed during regulatory inspection carried out by AERB. (author)

  5. Quality assurance test of a real time radiography system

    International Nuclear Information System (INIS)

    Yadav, R.K.; Rama, R.; Sharma, A.; Kannan, R.

    2005-01-01

    Any radiation generating equipment can be used and marketed in India only after obtaining specific type approval certificate from the Competent Authority i.e. Chairman, Atomic Energy Regulatory Board (AERB), Mumbai. Recently AERB has enforced a directive that the Industrial X-ray machines should also be permitted to use only after getting NOC or type approval. Type approval is granted based upon the satisfactory QA test report of the radiation generating equipment. X-ray machines with Real Time Radiography (RTR) facility are used in industrial radiography for faster inspection of equipment's and products online. A standard test protocol was developed for QA tests of a real time radiography system. This will be helpful for evaluation of an industrial X-ray machine. Also above procedure can be used to check a RTR system each day or a system-qualification can be done when the image quality diminishes as recommended by American Society of Testing Material (ASTM). Various tests carried out on a constant potential 450 kV, 10 mA industrial X-ray machine having real time radiography facility to monitor the products online, is described in this paper. (author)

  6. 10 CFR 34.13 - Specific license for industrial radiography.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Specific license for industrial radiography. 34.13 Section 34.13 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY... industrial radiography. An application for a specific license for the use of licensed material in industrial...

  7. Industrial radiography

    International Nuclear Information System (INIS)

    Aloni, A.; Magal, O.

    1992-02-01

    This publication is meant to be a manual for industrial radiography. As such the manual concentrates on the practical aspects, presenting existing radiographic system and techniques of operation to satisfy specified quality requirements. The manual also reviews the safety aspect of performing radiographic work. (author) systems

  8. Staff report on the environmental qualification of safety-related electrical equipment

    International Nuclear Information System (INIS)

    1977-12-01

    The current NRC safety review process for nuclear power plants includes criteria related to the qualification of certain electrical equipment. These criteria require that electrical equipment important to safety must be qualified to function in the environment that might result from various accident conditions. Although such criteria have been applied since the early days of commercial nuclear power, the details of these criteria have been changed over the years. The evolution of environmental qualification of safety-related electrical equipment is described in Appendix A

  9. Safety Testing of Industrial Radiography Devices

    International Nuclear Information System (INIS)

    Trapp, D.J.

    1999-01-01

    The Nuclear Regulatory Commission contracted the Savannah River Technology Center to verify the relevancy of the 10 CFR Part 34 requirements for the normal use of portable gamma radiography systems and to propose recommendations for changes or modifications to the requirements

  10. Safety code 19: recommended safety procedures for the selection, installation and use of x-ray diffraction equipment

    International Nuclear Information System (INIS)

    1984-01-01

    This document is one of a series of Safety Codes prepared by the Radiation Protection Bureau to set out requirements for the safe use of radiation emitting devices. The equipment and installation guidelines and safety procedures detailed in this Code are primarily for the instruction and guidance of persons employed in Federal Public Service Departments and Agencies, as well as those coming under the jurisdiction of the Canada Labour Code. This Safety Code is also intended to assist other users of X-ray diffraction equipment to select safe equipment and to install and use it so that the radiation hazard to the operator and other persons in its vicinity is negligible. It should be noted that facilities under provincial jurisdiction may be subject to requirements specified under provincial statutes. This Code supersedes Safety Code RPD-SC-7, entitled 'Requirements For Non-Medical X-Ray Equipment, Use and Installation', insofar as X-ray diffraction equipment is concerned, and it is intended to complement X-ray equipment design, construction and performance standards promulgated under the Radiation Emitting Devices Act

  11. 1E Qualification of Electrical Equipment - Requirement for Safety Nuclear Power Plants

    International Nuclear Information System (INIS)

    Geambasu, C.; Segarceanu, D.; Albu, J.

    2002-01-01

    The paper presents the qualification methods of the safety related equipment according to the safety class 1E. There are presented the qualification principles, procedure and documents, emphasis being laid on the qualification approach by type tests. This approach assumes the equipment test under both normal and accident conditions (design basis events) simulating the operational conditions and covers the largest part of electrical equipment from a nuclear power plant.The safety related equipment is to be qualified is subjected to a sequential test that will be detailed in the paper. (author)

  12. Nuclear safety regulation on nuclear safety equipment activities in relation to human and organizational factors

    International Nuclear Information System (INIS)

    Li Tianshu

    2013-01-01

    Based on years of knowledge in nuclear safety supervision and experience of investigating and dealing with violation events in repair welding of DFHM, this paper analyzes major faults in manufacturing and maintaining activities of nuclear safety equipment in relation to human and organizational factors. It could be deducted that human and organizational factors has definitely become key features in the development of nuclear energy and technology. Some feasible measures to reinforce supervision on nuclear safety equipment activities have also been proposed. (author)

  13. Preliminary results from the application of risk matrix method for safety assessment in industrial radiography; Resultados preliminares de la aplicacion del metodo de matrices de riesgo para evaluaciones de seguridad en radiografia industrial

    Energy Technology Data Exchange (ETDEWEB)

    Lopez G, A.; Cruz, D. [Comision Nacional de Seguridad Nuclear y Salvaguardias, Dr. Barragan 779, Col. Narvarte, 03020 Ciudad de Mexico (Mexico); Truppa, W. [Autoridad Reguladora Nuclear, Buenos Aires (Argentina); Aravena, M. [Comision Chilena de Energia Nuclear, Santiago (Chile); Tamayo, B., E-mail: alopezg@cnsns.gob.mx [Consejo de Seguridad Nuclear, Madrid (Spain)

    2015-09-15

    Although the uses of ionizing radiation in industry are subject to procedures that provide a high level of safety, experience has shown that equipment failure, human errors, or the combination of both that can trigger accidental exposures may occur. Traditionally, the radiation safety checks whether these industrial practices (industrial radiography, industrial irradiators, among others) are sufficiently safe to prevent similar accidental exposures already occurred, so that becomes dependent on the published information and not always answers questions like: What other events can occur, or what other risks are present? Taking into account the results achieved by the Foro Iberoamericano de Organismos Reguladores Radiologicos y Nucleares, its leading position in the use of techniques of risk analysis in radioactive facilities and the need to develop a proactive approach to the prevention of accidents arising from the use of ionizing radiations in the industry, it intends to apply the risk analysis technique known as Risk Matrix to a hypothetical reference entity for the region in which industrial radiography is performed. In this paper the results of the first stage of this study are shown, that is the identification of initiating events (IE) and barriers that help mitigate the consequences of such IE, so that can appreciate the applicability of this method to industrial radiography services, to reduce the risk to acceptable levels. The fundamental advantage associated with the application of this methodology is that can be applied by the professionals working in the service and identifies specific weaknesses that from the point of view of safety there, so they can be prioritized resources depending on risk reduction. (Author)

  14. Practical radiography. 11. ed.

    International Nuclear Information System (INIS)

    Hoxter, E.A.

    1982-01-01

    After a brief explanation of the basics of electricity, the fundamentals of radiography are dealt with in more detail - the discovery of X-rays, their nature and properties, the production of the X-ray image and ways of improving the image. A chapter is devoted to the important subject of radiation protection. Explanations are given of the use of the Siemens exposure tables, which make it simpler to modify exposures from the values given in the tables. There is also a section on some of the standard radiographic positioning for patients. The most common medical terms used in radiography and fluoroscopy are listed and an Appendix gives details of the major items of Siemens X-ray equipment. There is a list of literature recommended for further study. Theoretical explanations have been kept to a minimum so that information that is important to radiography can be emphasized. (orig./MG)

  15. The french safety approach regarding equipment qualification

    International Nuclear Information System (INIS)

    Jalouneix, J.; Deletre, G.; Henry, J.Y.; Rousseau, L.

    1989-10-01

    The qualification of the equipment, used in France on nuclear reactors and reactor components, is discussed. The approach on safety involves the qualification of mechanical and electrical components, under operating and under seismic conditions. The principles of the qualification program and the list of the equipment concerned, are given. The conditions in which qualification tests are performed and the methods applied, are summarized. The actions for preserving the qualification procedures, are considered

  16. Computed radiography

    International Nuclear Information System (INIS)

    Pupchek, G.

    2004-01-01

    Computed radiography (CR) is an image acquisition process that is used to create digital, 2-dimensional radiographs. CR employs a photostimulable phosphor-based imaging plate, replacing the standard x-ray film and intensifying screen combination. Conventional radiographic exposure equipment is used with no modification required to the existing system. CR can transform an analog x-ray department into a digital one and eliminates the need for chemicals, water, darkrooms and film processor headaches. (author)

  17. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone ...

  18. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... will analyze the images and send a signed report to your primary care or referring physician , who ... Medicine Radiation Safety How to Read Your Radiology Report Images related to X-ray (Radiography) - Bone Sponsored ...

  19. Quantitative density measurements from a real-time neutron radiography system

    International Nuclear Information System (INIS)

    McRae, D.D.; Jenkins, R.W. Jr.; Brenizer, J.S.; Tobin, K.W.; Hosticka, B.; Sulcoski, M.F.

    1986-01-01

    An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation

  20. Contemporary practice education: Exploring student perceptions of an industrial radiography placement for final year diagnostic radiography students

    International Nuclear Information System (INIS)

    Wareing, A.K.; Henderson, I.

    2015-01-01

    Introduction: There is a paucity of evidence in diagnostic radiography evaluating a career path into industrial imaging despite several higher education institutes stating this route as a career option on graduation. The link between a career in industrial radiography and diagnostic routes is unknown although there are anecdotal examples of individuals transferring between the two. Successfully obtaining a first post job following graduation in diagnostic radiography can be challenging in the current financial climate. A partnership was formed with an energy sector company that offered non-destructive testing/non-destructive evaluation (NDT/NDE) employing industrial radiographic technicians. Method: As an initial pilot, 5 (n = 5) final year diagnostic radiography students visited an industrial radiography site and underwent theoretical and practical training. Following this placement they engaged in a focus group and the student perceptions/responses were explored and recorded. Results: Common themes were identified and categorised via a thematic analysis. These were; radiation safety, physics and technology, widening access, graduate attributes/transferable skill sets and working conditions. Conclusion: Student discussion focussed around the benefits of working conditions in healthcare, the value of technology, safety and physics education in alternative placements and the transferability of skills into other/industrial sectors (e.g. NDT/NDE). Contemporary practice placements are a useful pedagogical approach to develop complex conceptual theoretical constructs, such as radiation physics. An in depth evaluation between the two industries skill sets is postulated. Additionally, this could offer alternative/emerging roles to interested diagnostic radiographers potentially meeting the skill shortage in industrial radiography. - Highlights: • Research in this area is novel. No evidence could be found to evaluate the links. • Students had theoretical

  1. Design review report for modifications to RMCS safety class equipment

    International Nuclear Information System (INIS)

    Corbett, J.E.

    1997-01-01

    This report documents the completion of the formal design review for modifications to the Rotary Mode Core Sampling (RMCS) safety class equipment. These modifications are intended to support core sampling operations in waste tanks requiring flammable gas controls. The objective of this review was to approve the Engineering Change Notices affecting safety class equipment used in the RMCS system. The conclusion reached by the review committee was that these changes are acceptable

  2. Design review report for modifications to RMCS safety class equipment

    Energy Technology Data Exchange (ETDEWEB)

    Corbett, J.E.

    1997-05-30

    This report documents the completion of the formal design review for modifications to the Rotary Mode Core Sampling (RMCS) safety class equipment. These modifications are intended to support core sampling operations in waste tanks requiring flammable gas controls. The objective of this review was to approve the Engineering Change Notices affecting safety class equipment used in the RMCS system. The conclusion reached by the review committee was that these changes are acceptable.

  3. Neutron induced electron radiography

    International Nuclear Information System (INIS)

    Andrade, Marcos Leandro Garcia

    2008-01-01

    In the present paper a new radiography technique, the 'Neutron Induced Electron Radiography' - NIER, to inspect low thickness samples on the order of micra, has been developed. This technique makes use of low energy electrons as penetrating radiation generated from metallic gadolinium screens when irradiated by thermal neutrons. The conditions to obtain the best image for the conventional X-ray film Kodak-AA were determined by using a digital system to quantify the darkening level of the film. The irradiations have been performed at a radiography equipment installed at the beam-hole no. 8 of the 5 MW IEA-R1 nuclear research reactor of IPEN-CNEN/SP. The irradiation time to obtain the best radiography was 100 seconds and for such condition the technique was able to discern 1 μm in 24 μm of aluminum at a resolution of 32 μm. By visual comparison the images obtained by the NIER shown a higher quality when compared with the ones from other usual techniques the make use of electrons a penetrating radiation and films for image registration. Furthermore the use of the digital system has provided a smaller time for data acquisition and data analysis as well as an improvement in the image visualization. (author)

  4. Regulatory Activities on Civil Nuclear Safety Equipment in China

    International Nuclear Information System (INIS)

    Gaoshang, Lu; Choi, Kwang Sik

    2011-01-01

    It is stipulated in IAEA Fundamental Safety Principles (SF1) that the fundamental safety objective is to protect people and the environment from harmful effects of ionizing radiation. The fundamental safety objective applies for all facilities and activities and for all stages over the lifetime of a facility or radiation source, including planning, sitting, design, manufacturing, construction, commissioning and operation, as well as decommissioning and closure. So, according to the requirement, the related activities such as design, manufacturing, installation and non-destructive test that conducted on civil nuclear equipment should be well controlled by the vendors, the owner of the nuclear power plants and the regulatory body. To insure the quality of those equipment, Chinese government had taken a series of measures to regulate the related activities on them

  5. Computer radiography - indirect digital radiography

    International Nuclear Information System (INIS)

    Jezierski, G.

    2008-01-01

    Implementation of the new European standards for industrial radiography with the use of storage phosphor imaging plates will result in the arousing of interest among numerous laboratories in non-destructive testing with application of the new method of testing to replace conventional radiography used so far, i.e. film radiography. Computer radiography is quite commonly used for medical radiography, where the fundamental problem consists in reduction of the radiation dose during the examination of a patient. However, it must be kept in mind that industrial applications have a little bit different requirements when compared with medical radiography. The article describes only new method for radiographic testing. (author)

  6. Apparatus for gamma ray radiography

    International Nuclear Information System (INIS)

    Kobayashi, Masatoshi; Enomoto, Shigemasa; Oga, Hiroshi

    1979-01-01

    This is the standard of Japan Non-Destructive Inspection Society, NDIS 1101-79, which stipulates on the design, construction and testing method of the apparatuses for gamma ray radiography used for taking industrial radiograms. The gamma ray apparatuses stipulated in this standard are those containing sealed radioactive isotopes exceeding 100 μCi, which emit gamma ray. The gamma ray apparatuses are classified into three groups according to their movability. The general design conditions, the irradiation dose rate and the sealed radiation sources for the gamma ray apparatuses are stipulated. The construction of the gamma ray apparatuses must be in accordance with the notification No. 52 of the Ministry of Labor, and safety devices and collimators must be equipped. The main bodies of the gamma ray apparatuses must pass the vibration test, penetration test, impact test and shielding efficiency test. The method of each test is described. The attached equipments must be also tested. The tests according to this standard are carried out by the makers of the apparatuses. The test records must be made when the apparatuses have passed the tests, and the test certificates are attached. The limit of guarantee by the endurance test must be clearly shown. The items to be shown on the apparatuses are stipulated. (Kako, I.)

  7. Safety for Compressed Gas and Air Equipment. Module SH-26. Safety and Health.

    Science.gov (United States)

    Center for Occupational Research and Development, Inc., Waco, TX.

    This student module on safety for compressed gas and air equipment is one of 50 modules concerned with job safety and health. This module presents technical data about commonly used gases and stresses the procedures necessary for safe handling of compressed gases. Following the introduction, 14 objectives (each keyed to a page in the text) the…

  8. The effect of using road safety equipment and systems and ...

    African Journals Online (AJOL)

    The effect of using road safety equipment and systems and determine their role on ... traffic control equipment situation and by multi-criteria weighting systems AHP ... The results have shown that indices median, lighting and panel type and the ...

  9. Problems associated with veterinary dental radiography

    International Nuclear Information System (INIS)

    Eisner, E.R.

    1990-01-01

    Veterinarians have been radiographing animal skulls for many years, but sophisticated dentistry was not widely used until the 1970s. Elevated awareness of veterinary dental techniques has led to the need for producing accurate radiographic images of the teeth and periodontal structures. Many problems arise for the clinician who treats small animals who has, before this time, radiographed the skull of dogs and cats solely for the purpose of assessing neoplastic, infectious, or traumatic disease of the mandible, maxilla, or calvarium and now desires to perform dental radiography. This chapter will describe the advantages and disadvantages of some of the more common types of radiographic equipment and supplies, discuss extraoral and intraoral radiographic positioning and technique, identify anatomic landmarks and diagnostic features of intraoral radiography, and offer suggestions concerning the art of using dental radiography in veterinary practice

  10. A safety equipment list for rotary mode core sampling systems operation in single shell flammable gas tanks

    International Nuclear Information System (INIS)

    SMALLEY, J.L.

    1999-01-01

    This document identifies all interim safety equipment to be used for rotary mode core sampling of single-shell flammable gas tanks utilizing Rotary Mode Core Sampling systems (RMCS). This document provides the safety equipment for RMCS trucks HO-68K-4600, HO-68K-4647, trucks three and four respectively, and associated equipment. It is not intended to replace or supersede WHC-SD-WM-SEL-023, (Kelly 1991), or WHC-SD-WM-SEL-032, (Corbett 1994), which classifies 80-68K-4344 and HO-68K-4345 respectively. The term ''safety equipment'' refers to safety class (SC) and safety significant (SS) equipment, where equipment refers to structures, systems and components (SSC's). The identification of safety equipment in this document is based on the credited design safety features and analysis contained in the Authorization Basis (AB) for rotary mode core sampling operations in single-shell flammable gas tanks. This is an interim safety classification since the AB is interim. This document will be updated to reflect the final RMCS equipment safety classification designations upon completion of a final AB which will be implemented with the release of the Final Safety Analysis Report (FSAR)

  11. Educational aspects of industrial radiography

    International Nuclear Information System (INIS)

    Krishnamurthy, K.; Wamorkar, R.R.; Singh, G.

    1979-01-01

    The state of art of training and education in non-destructive testing in India, with special reference to industrial radiography is reviewed. Basic requirement of industry and potential of radioisotopes in industrial inspection are also described. Need for an organised training programme in industrial isotope radiography to exploit potentials for benefit of industry concurrent with the safety is stressed. A comprehensive training programme tailored to meet the needs of Indian industry is outlined. Benefits obtained from the course to the industry since the beginning of the training programme are briefly reviewed. (auth.)

  12. Dosimetric evaluation in panoramic and tele-radiography procedures

    International Nuclear Information System (INIS)

    Oliveira, Georgge Gomes

    2004-01-01

    The present work had as an objective to evaluate the skin surface entrance dose in panoramic and tele radiography procedures in three clinics in Recife - Pernambuco - Brazil, and to contribute with data for the determination of reference levels for super cited extra oral procedures, for this purpose, operational conditions in 3 clinics were evaluated in Recife, aiming to evaluate the existence and integrity of the radioprotection equipment, manner and conditions of image processing; and radiographic equipment parameters such as the dimension of the irradiation filed, the total filtration, the exposure time and the potential applied to the X ray tube. For an estimation of the skin entrance dose of the patient, the phantom Randon Alderson and thermoluminescence dosemeters were used. From these values and the conversion factors determined by the Monte Carlo technique, with the phantom MAX it was possible to estimate the dose absorbed in the organ due to the tele radiography procedures. Regarding panoramic radiography the study showed that the more elevated doses occurred in the parotid gland region which is near rotational venters. In the case of tele radiography the highest dose value occurred in the regions corresponding to the temporal lobe of the brain, followed by linfonodes, ears and parotid glands. The doses absorbed in the eyes and the thyroid gland were, 0.037 mGy and 0.002 mGy in Clinic A and 0.062 mGy and 0.003 mGy in Clinic C, respectively. Regarding equipment test, inadequacy was found in the beam collimation in Clinic A and in the reproducibility of the X ray exposure in Clinic C. The total filtration in both clinics was inadequate.(author)

  13. Safety systems I/C equipment reliability analyses of the Kozloduy NPP units 3 and 4

    Energy Technology Data Exchange (ETDEWEB)

    Halev, G; Christov, N [Risk Engineering Ltd., Sofia (Bulgaria)

    1996-12-31

    The purpose of the analysis is to assess the safety systems I/C equipment reliability. The assessment includes: quantification of the safety systems unavailability due to component failures; definition of the minimal cut sets leading to the analysed safety systems failure; quantification of the I/C equipment importance measures of the dominant contribution components. The safety systems I/C equipment reliability has been analysed using PSAPACK (a code for probabilistic safety assessment). Fault trees for the following safety systems of the Kozloduy-3 and Kozloduy-4 reactors have been constructed: neutron flow control equipment, reactor protection system, main coolant pumps, pressurizer safety valves `Sempell`, steam dump systems, spray system, low pressure injection system, emergency feeding water system, essential service water system. THree separate reports have been issued containing the performed analyses and results. 1 ref.

  14. Patient obesity and the practical experience of the plain radiography professional: On everyday ethics, patient positioning and infelicitous equipment

    International Nuclear Information System (INIS)

    Woods, A.L.; Miller, P.K.; Sloane, C.

    2016-01-01

    Patient obesity is increasingly placing significant and multifaceted strain upon medical imaging departments, and professionals, in (particularly Western) healthcare systems. The majority of obesity-related studies in radiology are, however, primarily focused only upon the technical business of collecting diagnostically-efficacious images. This study, using Interpretative Phenomenological Analysis (IPA), qualitatively explores the everyday clinical experiences of eight expert UK diagnosticians working in plain radiography. Focus herein falls particularly upon (a) problems with patient positioning during examination, and (b) challenges arising around available equipment. In line with extant research, participants reported that difficulties with positioning obese patients could have negative impacts on image quality, and that insufficient table weight limits and widths, and inadequate detector sizes, can adversely affect examination. They also raised some more novel issues, such as how the impact of available gown sizes upon a patient's sense of dignity can cause practical and ethical dilemmas for a clinician in situ. The issue of how one might ‘train’ experience in positioning patients without bony landmarks as a reference point was also made salient, with strong implications for undergraduate radiography curricula. It is finally highlighted how the participating radiographers themselves seldom conceptualised any given problem as a purely ‘technical’ one, instead recurrently recognising the interlinking of material, socio-economic and moral matters in real healthcare contexts. By better understanding such nuance and complexity as lived by real radiographers, it is contended, a more context-sensitive and flexible path to effective training and guideline-production can be mapped. - Highlights: • Difficulties with positioning obese patients can have negative impacts on image quality. • Positioning patients without bony landmarks as a reference point is

  15. Flash x-radiography for material motion detection

    International Nuclear Information System (INIS)

    Choate, L.M.; Buckalew, W.H.; Posey, L.D.

    1977-01-01

    A significant part of the experimental program dealing with the behavior of prototypic LMFBR fuel pin bundles under mild to severe power transients is that of the observation of fuel/cladding/coolant motion. The feasibility of using electron beam flash x-radiography as a diagnostic tool for safety test facilities is presently under evaluation. A summary of the objectives and approach of the flash x-radiography program is presented

  16. IEEE standard for design qualification of safety systems equipment used in nuclear power generating stations

    International Nuclear Information System (INIS)

    Anon.

    1980-01-01

    This standard is written to serve as a general standard for qualification of all types of safety systems equipment, mechanical and instrumentation as well as electrical. It also establishes principles and procedures to be followed in preparing specific safety systems equipment standards. Guidance for qualifying specific safety systems equipment may be found in various specific equipment qualification standards that are now available or are being prepared. It is required that safety systems equipment in nuclear power generating stations meet or exceed its performance requirements throughout its installed life. This is accomplished by a disciplined program of design qualification and quality assurance of design, production, installation, maintenance and surveillance. This standard is for the design qualification section of the program only. Design qualification is intended to demonstrate the capability of the equipment design to perform its safety function(s) over the expected range of normal, abnormal, design basis event, post design basis event, and in-service test conditions. Inherent to design qualification is the requirement for demonstration, within limitations afforded by established technical state-of-the-art, that in-service aging throughout the qualified life established for the equipment will not degrade safety systems equipment from its original design condition to the point where it cannot perform its required safety function(s), upon demand. The above requirement reflects the primary role of design qualification to provide reasonable assurance that design- and age-related common failure modes will not occur during performance of safety function(s) under postulated service conditions

  17. Industrial radiography X and Gamma

    International Nuclear Information System (INIS)

    Torres M, Nelson; Torres B, Miguel; Montanez, Juan.

    1986-04-01

    This publication gives a practical orientation on industrial radiography. The first chapters deal with basic facts that are useful for professional work in this field. It comprises topics such as generation of X-rays, equipment being used, radiographic films, sensibility, and the penetrameters used. This publication also describes the most used radiographic techniques and the processing of the radiographic film. It contains practical recommendations on how to obtain a good radiographic inspection. It states the reasons for defects in the radiographies. Two annexes are attached which include tables for the selection of penetrameters according to the ASME and DIN codes as well as the time needed for development and fixing according to the temperature

  18. 38 CFR 17.155 - Minimum standards of safety and quality for automotive adaptive equipment.

    Science.gov (United States)

    2010-07-01

    ... safety and quality for automotive adaptive equipment. 17.155 Section 17.155 Pensions, Bonuses, and... Minimum standards of safety and quality for automotive adaptive equipment. (a) The Under Secretary for... officials that it meets implicit standards of safety and quality adopted by the industry or as later...

  19. Safety of nursing staff and determinants of adherence to personal protective equipment.

    Science.gov (United States)

    Neves, Heliny Carneiro Cunha; Souza, Adenícia Custódia Silva e; Medeiros, Marcelo; Munari, Denize Bouttelet; Ribeiro, Luana Cássia Miranda; Tipple, Anaclara Ferreira Veiga

    2011-01-01

    A qualitative study conducted in a teaching hospital with 15 nursing professionals. Attempted to analyze the reasons, attitudes and beliefs of nursing staff regarding adherence to personal protective equipment. Data were collected through focus groups, analyzed by the method of interpretation of meanings, considering Rosenstock's model of health beliefs as a reference framework. Data revealed two themes: Occupational safety and Interpersonal Relationship. We identified several barriers that interfere in matters of safety and personal protective equipment, such as communication, work overload, physical structure, accessibility of protective equipment and organizational and management aspects. Adherence to personal protective equipment is determined by the context experienced in the workplace, as well as by individual values and beliefs, but the decision to use the personal protective equipment is individual.

  20. Digital Radiography

    Science.gov (United States)

    1986-01-01

    System One, a digital radiography system, incorporates a reusable image medium (RIM) which retains an image. No film is needed; the RIM is read with a laser scanner, and the information is used to produce a digital image on an image processor. The image is stored on an optical disc. System allows the radiologist to "dial away" unwanted images to compare views on three screens. It is compatible with existing equipment and cost efficient. It was commercialized by a Stanford researcher from energy selective technology developed under a NASA grant.

  1. Study on the characterization of the neutron radiography facility in HANARO for two-phase flow research

    International Nuclear Information System (INIS)

    Lim, I. C.; Seo, C. G.; Jeong, J. H.; Lee, B. H.; Choi, Y. S.

    2001-01-01

    For the application of dynamic neutron radiography to the two-phase flow research using HANARO, several experimental items to which the radiography technique is beneficial were identified through the review of the outputs from the related researches and the discussions with experts. Also, the investigation of the equipments including the beam port, camera and converter was made and a hardware and a software for image processing were equipped. It was confirmed that the calibration curve for the attenuation of neutron beam in fluid which is required for the two-phase flow experiment could be obtained by the computer code calculation. Based on the investigation results on the equipment and the results from the measurement of BNCT beam characteristics, a high speed camera and an image intensifier will be purchased. Then, the high speed dynamic neutron radiography facility for two-phase flow experiments will be fully equipped

  2. Study on the characterization of the neutron radiography facility in HANARO for two-phase flow research

    Energy Technology Data Exchange (ETDEWEB)

    Lim, I. C.; Seo, C. G.; Jeong, J. H.; Lee, B. H.; Choi, Y. S

    2001-01-01

    For the application of dynamic neutron radiography to the two-phase flow research using HANARO, several experimental items to which the radiography technique is beneficial were identified through the review of the outputs from the related researches and the discussions with experts. Also, the investigation of the equipments including the beam port, camera and converter was made and a hardware and a software for image processing were equipped. It was confirmed that the calibration curve for the attenuation of neutron beam in fluid which is required for the two-phase flow experiment could be obtained by the computer code calculation. Based on the investigation results on the equipment and the results from the measurement of BNCT beam characteristics, a high speed camera and an image intensifier will be purchased. Then, the high speed dynamic neutron radiography facility for two-phase flow experiments will be fully equipped.

  3. Analysis for making a regulatory decision to equipment of industrial gammagraphy in Argentin

    International Nuclear Information System (INIS)

    Ermacora, Marcela G.; Vidal, Dora N.; Alonso, Maria T.

    2013-01-01

    Industrial gammagraphy is a practice widely used as a nondestructive testing technique in Argentina. Experience worldwide has shown the need for an improvement in the intrinsic safety of the equipment used in this lab. In response to this reason, the board of the Nuclear Regulatory Authority (ARN) has considered a proposal to withdraw service movement and much of the equipment inventory scan belonging to industrial facilities nationwide. The main objective of this paper is to present the results of the analysis performed to support the above proposal. The main elements of evaluation can be summarized as follows: I) the teams that do not conform to international recommendations regarding compliance with key safety requirements of international standards such as ISO 3999:2004 (E) R adiation protection - Industrial Apparatus for gamma radiography - Specifications for performance, design and tests ; II) the decision by some manufacturers to discontinue production of certain models of equipment and the provision of spare parts, and III) the validity of certificates bulk type B (U) for transport. In conclusion, it highlights the importance of a regulatory decision supplementary to the Standard AR 7.9.1 concerning the operation of scan equipment industry, based on current international recommendations and Argentina's commitment to good practice and safety culture which can lead to a positive impact on radiation safety in this art

  4. Navigation Tools and Equipment and How They Have Improved Aviation Safety

    OpenAIRE

    Sulaiman D. S Alsahli FadalahassanALfadala

    2017-01-01

    This paper highlights the impact of navigation tools and equipment, such as the GPS, navigation radar, and other communications tools, which aid in ensuring aviation safety. It emphasizes the need for aviation safety and how these navigation methods are of great help to reduce the hazards and clearly indicate the problems related to the aircraft, aircraft traffic management, weather disturbances, among others. It also recommends how these tools and equipment must be further developed to promo...

  5. The stationary neutron radiography system: a TRIGA-based production neutron radiography facility

    International Nuclear Information System (INIS)

    Chesworth, Robert H.; Hagmann, Dean B.

    1988-01-01

    General Atomics (GA) is under contract to construct a Stationary Neutron Radiography System (SNRS) - on a turnkey basis - at McClellan Air Force Base in Sacramento, California. The SNRS is a custom designed neutron radiography system which will utilize a 1000 KW TRIGA reactor as the neutron source. The partially below-ground reactor will be equipped with four inclined beam tubes originating near the top of the reactor graphite reflector and installed tangential to the reactor core to provide a strong current of thermal neutrons with minimum gamma ray contamination. The inclined beam tubes will terminate in four large bays and will interface with rugged component positioning systems designed to handle intact aircraft wings, other honeycomb aircraft structures, and pyrotechnics. The SNRS will be equipped with real-time, near real-time, and film radiographic imaging systems to provide a broad spectrum of capability for detection of entrained moisture or corrosion in large aircraft panels. GA is prime contractor to the Air Force for the SNRS and is specifically responsible for the TRIGA reactor system and a portion of the neutron beam system design. Science Applications International Corporation and the Lionakis-Beaumont Design Group are principal subcontractors to GA on the project. (author)

  6. Nuclear power plants. Electrical equipment of the safety system. Qualification

    International Nuclear Information System (INIS)

    2001-01-01

    This International Standard applies to electrical parts of safety systems employed at nuclear power plants, including components and equipment of any interface whose failure could affect unfavourably properties of the safety system. The standard also applies to non-electrical safety-related interfaces. Furthermore, the standard describes the generic process of qualification certification procedures and methods of qualification testing and related documentation. (P.A.)

  7. The use of portable shields in industrial radiography

    International Nuclear Information System (INIS)

    Oliveira e Silva, J.A. de.

    1988-01-01

    This paper shows techniques actually used to reduce radiations exposure taxes during examinations execution by gamma radiography in regions of high population density. A portable equipment of radiation shield for using in exams by gamma radiography in pipelines, that is an adjustable device in an object body that will be examined, joining a measured collimator and a shield geometrically arranged so that the radiation restrict to impress the radiographic film used in examination without reaching people, objects or self-movings injurious that are nearness. (C.M.) [pt

  8. A safety equipment list for rotary mode core sampling systems operation in single shell flammable gas tanks; TOPICAL

    International Nuclear Information System (INIS)

    SMALLEY, J.L.

    1999-01-01

    This document identifies all interim safety equipment to be used for rotary mode core sampling of single-shell flammable gas tanks utilizing Rotary Mode Core Sampling systems (RMCS). This document provides the safety equipment for RMCS trucks HO-68K-4600, HO-68K-4647, trucks three and four respectively, and associated equipment. It is not intended to replace or supersede WHC-SD-WM-SEL-023, (Kelly 1991), or WHC-SD-WM-SEL-032, (Corbett 1994), which classifies 80-68K-4344 and HO-68K-4345 respectively. The term ''safety equipment'' refers to safety class (SC) and safety significant (SS) equipment, where equipment refers to structures, systems and components (SSC's). The identification of safety equipment in this document is based on the credited design safety features and analysis contained in the Authorization Basis (AB) for rotary mode core sampling operations in single-shell flammable gas tanks. This is an interim safety classification since the AB is interim. This document will be updated to reflect the final RMCS equipment safety classification designations upon completion of a final AB which will be implemented with the release of the Final Safety Analysis Report (FSAR)

  9. Application of quality assurance program to safety related aging equipment or components

    International Nuclear Information System (INIS)

    Papaiya, N.C.

    1990-01-01

    This paper addresses how quality assurance programs and their criteria are applied to safety related and aging equipment or components used in commercial nuclear plant applications. The QA Programs referred to are 10CFR50 Appendix B and EPRI NP-5652. The QA programs as applicable are applied to equipment/component aging qualification, preventive maintenance, surveillance testing and procurement engineering. The intent of this paper is not the technical issues, methods and research of aging. The paper addresses QA program's application to age-related equipment or components in safety related applications. Quality Assurance Program 10CFR50 Appendix B applies to all safety related aging components or equipment related to the qualification program and associated preventive maintenance and surveillance testing programs. Quality Assurance involvement with procurement engineering for age-related commercial grade items supports EPRI NP-5652 and assures that the dedicated OGI is equal to the item purchased as a basic component to 10CFR50 Appendix B requirements

  10. Computed Radiography: An Innovative Inspection Technique

    International Nuclear Information System (INIS)

    Klein, William A.; Councill, Donald L.

    2002-01-01

    Florida Power and Light Company's (FPL) Nuclear Division combined two diverse technologies to create an innovative inspection technique, Computed Radiography, that improves personnel safety and unit reliability while reducing inspection costs. This technique was pioneered in the medical field and applied in the Nuclear Division initially to detect piping degradation due to flow-accelerated corrosion. Component degradation can be detected by this additional technique. This approach permits FPL to reduce inspection costs, perform on line examinations (no generation curtailment), and to maintain or improve both personnel safety and unit reliability. Computed Radiography is a very versatile tool capable of other uses: - improving the external corrosion program by permitting inspections underneath insulation, and - diagnosing system and component problems such as valve positions, without the need to shutdown or disassemble the component. (authors)

  11. Development of Automatic Remote Exposure Controller for Gamma Radiography

    International Nuclear Information System (INIS)

    Joo, Gwang Tae; Shin, Jin Seong; Kim, Dong Eun; Song, Jung Ho; Choo, Seung Hwan; Chang, Hong Keun

    2002-01-01

    Recently, gamma radiographic equipment have been used about 1,000 sets manually and operated by about 2,500 persons in Korea. In order for a radiography to work effectively with avoiding any hazard of the high level radiation from the source, many field workers have expected developing a wireless automatic remote exposure controller. The KlTCO research team has developed an automatic remote exposure controller that can regulate the speed of 0.4∼1.2m/s by BLDC motor of 24V 200W which has output of 54 kgf·, suitable torque and safety factor for the work. And the developed automatic remote exposure controller can control rpm of motor, pigtail position by photo-sensor and exposure time by timer to RF sensor. Thus, the developed equipment is expected that the unit can be used in many practical applications with benefits in economical advantage to combine the use of both automatic and manual type because attachment is possible existent manual remote exposure controller, AC and DC combined use

  12. Impact of pre-conditioning on the qualification of safety-related equipment

    International Nuclear Information System (INIS)

    Isgro, J.R.

    1982-01-01

    This paper shares some recent experiences on the effects of preconditioning on the qualification of safety-related equipment not located in a harsh environment. Environmental and seismic qualification testing programs were conducted following the guidelines of IEEE 323-1974, IEEE 344-1975 and appropriate IEEE daughter standards, where available. The examples that follow will illustrate the degree of pre-conditioning of safety-related equipment qualified to the requirements of IEEE-323-1974, and its effect on the outcome of the qualification program

  13. Quality assurance procedure for functional performance of industrial gamma radiography exposure devices

    International Nuclear Information System (INIS)

    Kannan, R.; Yadav, R.K.; Rajoo Kumar; Bhatt, B.C.; Sivaraman, G.; Nandkumar, A.N.

    2003-05-01

    An Industrial Gamma Radiography Exposure Device (IGRED) consists of various moving parts and accessories and wear and tear take place often. This may increase the possibility of radiation incidents and result in avoidable radiation exposure. Quality assurance tests of the equipment for functional performance plays a major role in ensuring that the exposure device and its accessories perform their intended functions and satisfy radiation safety requirements to avert potential exposures to operators. Therefore, in India it is practiced as mandatory requirement that each IGRED is tested for its functional performance and only after ascertaining that features of operational safety are satisfactory, loading of the source into the radiography exposure device can be permitted. This procedure which is being. practiced since the late 1970s, has contributed significantly towards the safe use of IGREDs and minimising the occurrence of radiation accidents. The purpose of this document is to highlight the importance of periodic functional performance check of each IGRED as per the checklist for the testing procedures. It is also proposed to entrust this activity to accredited laboratories, which have the necessary infrastructure to carry out this activity. The prerequisites for accreditation of such laboratories to carry out this activity and the testing procedures to be adopted for checking the functional performance of various models of IGREDs used in this country are given in this report. (author)

  14. Proceedings of 7th short conference on neutron radiography

    International Nuclear Information System (INIS)

    Hiraoka, Eiichi; Katsurayama, Kousuke; Tsujimoto, Tadashi

    1986-10-01

    The first short period conference on neutron radiography was held in 1970, and now the 7th meeting was held. The works to develop neutron radiography in Japan are as active as those in western countries, and the research is in progress by using neutrons from reactors, radioisotopes and accelerators in order to achieve the technology of high standard. In this conference, 26 papers and six comments were presented, and the themes covered the equipment for radiography, the practical application, and the related research. The second World Conference on Neutron Radiography will be held in Paris in June, 1986, and the further promotion of the spread of neutron radiography can be expected. The proceedings of the conference is published with the hope that joint effort and information exchange are further enhanced in coming years to develop the neutron radiography in Japan. The neutron radiography using the Kinki University reactor, the Rikkyo Triga-2 reactor, the Musashi reactor, the Kyoto research reactor, a 3MV Van de Graaff accelerator in Toyota, a subcompact cyclotron in Sumitomo, a baby cyclotron-dual collimator in National Space Development Agency and so on, Cf-252 based thermal neutron radiography, CT with Sb-124/Be neutrons, pulse power neutron source, imaging converters, neutron radiographic image processing, computed tomography using neutron television systems and others are reported. (Kako, I.)

  15. A new approach to determine the environmental qualification requirements for the safety related equipment

    International Nuclear Information System (INIS)

    Hasnaoui, C.; Parent, G.

    2000-01-01

    The objective of the environmental qualification of safety related equipment is to ensure that the plant defense-in-depth is not compromised by common mode failures following design basis accidents with a harsh environment. A new approach based on safety functions has been developed to determine what safety-related equipment is required to function during and after a design basis accident, as well as their environmental qualification requirements. The main feature of this approach is to use auxiliary safety functions established from safety requirements as credited in the safety analyses. This approach is undertaken in three steps: identification of the auxiliary safety functions of each main safety function; determination of the main equipment groups required for each auxiliary safety function; and review of the safety analyses for design basis accidents in order to determine the credited auxiliary safety functions and their mission times for each accident scenario. Some of the benefits of the proposed approach for the determination of the safety environmental qualification requirements are: a systematic approach for the review of safety analyses based on a safety function check list, and the insurance, with the availability of the safety functions, that Gentilly-2 defense-in-depth would not be compromised by design basis accidents with a harsh environment. (author)

  16. National reference doses for dental cephalometric radiography.

    Science.gov (United States)

    Holroyd, J R

    2011-12-01

    Diagnostic reference levels (DRLs) are an important tool in the optimisation of clinical radiography. Although national DRLs are provided for many diagnostic procedures including dental intra-oral radiography, there are currently no national DRLs set for cephalometric radiography. In the absence of formal national DRLs, the Health Protection Agency (HPA) has previously published National Reference Doses (NRDs) covering a wide range of diagnostic X-ray examinations. The aim of this study was to determine provisional NRDs for cephalometric radiography. Measurements made by the Dental X-ray Protection Service (DXPS) of the HPA, as part of the cephalometric X-ray equipment testing service provided to dentists and dental trade companies throughout the UK, were used to derive provisional NRDs. Dose-area product measurements were made on 42 X-ray sets. Third quartile dose-area product values for adult and child lateral cephalometric radiography were found to be 41 mGy cm² and 25 mGy cm², respectively, with individual measurements ranging from 3 mGy cm² to 108 mGy cm². This report proposes provisional NRDs of 40 mGy cm² and 25 mGy cm² for adult and child lateral cephalometric radiographs, respectively; these doses could be considered by employers when establishing their local DRLs.

  17. Computed radiography in NDT application

    International Nuclear Information System (INIS)

    Deprins, Eric

    2004-01-01

    Computed Radiography, or digital radiography by use of reusable Storage Phosphor screens, offers a convenient and reliable way to replace film. In addition to the reduced cost on consumables, the return on investment of CR systems is strongly determined by savings in exposure time, processing times and archival times. But also intangible costs like plant shutdown, environment safety and longer usability of isotopes are increasingly important when considering replacing film by Storage Phosphor systems. But mote than in traditional radiography, the use of digital images is a trade-off between the speed and the required quality. Better image quality is obtained by longer exposure times, slower phosphor screens and higher scan resolutions. Therefore, different kinds of storage phosphor screens are needed in order to cover every application. Most operations have the data, associated with the tests to be performed, centrally stored in a database. Using a digital radiography system gives not only the advantages of the manipulation of digital images, but also the digital data that is associated with it. Smart methods to associate cassettes and Storage screens with exposed images enhance the workflow of the NDT processes, and avoid human error. Automated measurements tools increase the throughput in different kinds of operations. This paper gives an overview of the way certain operations have decided to replace film by Computed Radiography, and what the major benefits for them have been.

  18. Standardization and improvement of safety for radioisotope equipped instruments

    International Nuclear Information System (INIS)

    Sumi, Tetsuo

    1980-01-01

    The safety for radioisotope-equipped instruments is considered. The one is the safety for the source assembly. The radioisotopes employed for radioisotope-equipped instruments are sealed sources which are used in the state of being contained in the enclosures. Many of the enclosures are provided with shutter mechanism for the purpose of emitting radiation only during the period required. If the possible troubles that might lead to the accidents are sampled out of the results of field operation of radiation instruments, and the safety measures for source enclosures are considered in connection with these troubles, it is no exaggeration to say that the safety for source enclosures has been maintained by preventing the critical accidents by the management of users and the cooperation of manufactures though there were the chance for investigating the safety in the common field and the establishment of JIS Z 4614 standard. Another consideration is concerned with the measures to improve the safety. No accident in the past never guarantees no accident in the future. Accumulation of experience is most effective for those measures, and the more experiences the better. It may be most effective that the manufacturers disclose their experiences each other from the wide outlook overcoming the barrier of trade secret. Fortunately, such consciousness has risen since a few years ago, and the investigation group is doing the works in the Japan Radioisotope Association. On the other hand, the reasonable revision of the radiation injury prevention law is desired. (Wakatsuki, Y.)

  19. Industrial Radiography: Principle and Practical

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    The successful and effectiveness of radiography method as a tool to increase quality level and safety of the engineering system and processing plants depend with the level of radiographer knowledge as service provider and also as supervisor. This book was published as effort several local experts to give their knowledge, theory and practical related to radiography technique to the involved public directly or indirectly. This book started with basic physic knowledge that becomes a root to radiography technology. Then, followed by discussion on tools and device that used in radiography work including x-ray machine, gamma projector, film, dark room, and others. Each aspect of radiograph quality also mentioned here to guide the reader on how to produce good radiograph that filled the specification wanted. The good radiograph does not mean anything if it failed to be interpreted correctly. Because of that, this book also explain how to choose good radiograph that qualified to be interpreted and after that how interpretation and evaluation process of object quality inspected was implemented based on image digestion that showed in radiograph. Several code and standard that usually applied in this country also will be referred as well for this work.

  20. L-038: EPR-First Responders: Forces / safety equipment. Action Guides

    International Nuclear Information System (INIS)

    2011-01-01

    This conference is about the actions carry out by the forces and the safety equipment in a radiological emergency. The security area, the victims, the hospitals, the police vehicles area, the safety cordon, the evacuation, the contamination level and the risk of life are important aspects to be considered by the first responders.

  1. Evidence for the safety assurance of the radiation associated equipments for stat-up check

    International Nuclear Information System (INIS)

    Takahashi, Yasuyuki; Igarashi, Hiroshi; Saito, Kyoko; Kawaharada, Yasuhiro; Hirano, Kunihiro; Murase, Kenya; Mochizuki, Teruhito

    2008-01-01

    Based on the new amendment of the Medical Service Law and the Pharmaceutical Affairs Law, the safety control for the medical equipments and devices was strengthened; and a radiological technologist should be stipulated as a safety control manager for the medical equipments and devices. Although it is thought that Start-up check is important for the safety assurance, the enforcement situation is not clear until now. In this report, on the occasion of the start-up of the new Law, questionnaire about the start up check (time and a check items) were investigated from 56 hospitals applying the visit interview. Modality by modality check up time was obtained from 261 institutions by the descriptive study paper type. Start-up check and arming up were applied for almost all modalities about 30 minutes before start of the clinical tests. The check up items for the medical equipments and devices depended on each hospital. Therefore, safety assurance should be established, cooperating with the medical equipment distributors, the hospital sharing the checked results for the patients' safety. (author)

  2. Special equipment for etching nitrocellulose film

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1983-08-01

    Nitrocellulose film and converter screens used for neutron radiography are described. Difficulties in visualization of radiographs on those films are mentioned. Because there is no equipment for etching nitrocellulose film available on the market Risoe has designed and produced such equipment at an estimated cost of Dkr. 15,000. Design criteria for this equipment are given and its performance described

  3. Californium Multiplier. Part I. Design for neutron radiography

    International Nuclear Information System (INIS)

    Crosbie, K.L.; Preskitt, C.A.; John, J.; Hastings, J.D.

    1982-01-01

    The Californium Multiplier (CFX) is a subcritical assembly of enriched uranium surrounding a californium-252 neutron source. The function of the CFX is to multiply the neutrons emitted by the source to a number sufficient for neutron radiography. The CFX is designed to provide a collimated beam of thermal neutrons from which the gamma radiation is filtered, and the scattered neutrons are reduced to make it suitable for high resolution radiography. The entire system has inherent safety features, which provide for system and personnel safety, and it operates at moderate cost. In Part I, the CFX and the theory of its operation are described in detail. Part II covers the performance of the Mound Facility CFX

  4. ENEA TRIGA RC-1 reactor activities in the fields of nuclear medicine and neutron radiography

    International Nuclear Information System (INIS)

    Chiesa, Gianni; Festinesi, Armando; Palomba, Mario; Rosa, Roberto; Rossi, Gabriela; Sangiovanni, Gino; Santoro, Emilio; Sedda, Antioco Franco; Storelli, Lucio

    2008-01-01

    In the last three years, TRIGA RC-1 plant staff is involved in collaborations with some roman hospitals for the production of particular radioisotopes for the diagnosis and therapy in the field of human cancer. Further, the thermal column of TRIGA reactor has been prepared for neutron radiography and tomography. For another channel, instruments and equipment above neutron radiography and tomography are in preparation phase. This paper includes an overview of the experimental equipment properly developed by TRIGA staff. (authors)

  5. Safety analysis report for packaging (onsite) decontaminated equipment self-container

    International Nuclear Information System (INIS)

    Boehnke, W.M.

    1998-01-01

    The purpose of this Safety Analysis Report for Packaging (SARP) is to demonstrate that specific decontaminated equipment can be safely used as its own self-container. As a Decontaminated Equipment Self-Container (also referred to as a self-container), no other packaging, such as a burial box, would be required to transport the equipment onsite. The self-container will consist of a piece of equipment or apparatus which has all readily removable interior contamination removed, all of its external openings sealed, and all external surfaces decontaminated to less than 2000 dpm/100 cm for gamma-emitting radionuclides and less than 220 dpm/100 CM2 for alpha-emitting radionuclides

  6. Manual on industrial radiography

    International Nuclear Information System (INIS)

    1981-08-01

    This manual is intended as a source of educational material to personnel seeking certification as industrial radiographers, and as a guide and reference text for educational organizations that are providng courses in industrial radiography. It covers the basic principles of x-ray and gamma radiation, radiation safety, films and film processing, welding, casting and forging, aircraft structures and components, radiographic techniques, and records

  7. Guideline on evaluation and acceptance of commercial grade digital equipment for nuclear safety applications

    International Nuclear Information System (INIS)

    1996-10-01

    Nuclear power plants are increasingly upgrading their instrumentation and control (I ampersand C) systems with commercial digital equipment, which allows them to continue meeting safety and reliability requirements while controlling operating costs. However, the use of commercial software-based devices for safety related applications has raised new issues that impact design, procurement, and licensing activities. This guideline describes a consistent, comprehensive approach for the evaluation and acceptance of commercial digital equipment for nuclear safety systems

  8. Neutron radiography (NRAD) reactor 64-element core upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Bess, John D. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-03-01

    The neutron radiography (NRAD) reactor is a 250 kW TRIGA (registered) (Training, Research, Isotopes, General Atomics) Mark II , tank-type research reactor currently located in the basement, below the main hot cell, of the Hot Fuel Examination Facility (HFEF) at the Idaho National Laboratory (INL). It is equipped with two beam tubes with separate radiography stations for the performance of neutron radiography irradiation on small test components. The interim critical configuration developed during the core upgrade, which contains only 62 fuel elements, has been evaluated as an acceptable benchmark experiment. The final 64-fuel-element operational core configuration of the NRAD LEU TRIGA reactor has also been evaluated as an acceptable benchmark experiment. Calculated eigenvalues differ significantly (approximately ±1%) from the benchmark eigenvalue and have demonstrated sensitivity to the thermal scattering treatment of hydrogen in the U-Er-Zr-H fuel.

  9. Neutron radiography

    International Nuclear Information System (INIS)

    Hrdlicka, Z.

    1977-01-01

    Neutron radiography is a radiographic method using a neutron beam of a defined geometry. The neutron source usually consists of a research reactor, a specialized neutron radiography reactor or the 252 Cf radioisotope source. There are two types of the neutron radiography display system, viz., a system producing neutron radiography images by a photographic process or a system allowing a visual display, eg., using a television monitor. The method can be used wherever X-ray radiography is used except applications in the radiography of humans. The neutron radiography unit at UJV uses the WWR-S reactor as the neutron source and both types of the above mentioned display system. (J.P.)

  10. New prospect in neutron radiography

    International Nuclear Information System (INIS)

    Cluzeau, S.

    1991-01-01

    Neutron radiography is a very useful non-destructive testing (NDT) method which frequently complements classical X-ray inspection. Numerous inspections in some fields are currently performed at reactor-based neutron radiography facilities but many other interesting applications in different fields are at present not considered because the objects to be tested cannot be moved to a reactor. It is the goal of the DIANE project, to allow the utilization of this NDT method in industrial facilities by developing a safe and convenient neutron radiography equipment using an ''on-off'' neutron source. As a result of the efforts of the four European partners, a first laboratory demonstration model is currently in operation in Germany and a fully mobile second one is expected by the end of 1992. Good radiographs are obtained with exposure times in the range of a few seconds to ten minutes using an electronic imaging system. The fast neutron generator uses a sealed neutron tube delivering 5.10 11 neutrons.cm -2 .s -1 in 4 π steradian; with a collimator ratio of about 12, the fluence rate onto the object is then close to 1,5.10 5 thermal neutrons.cm -2 .s -1 . (author)

  11. Radiation dose distribution monitoring at neutron radiography facility area, Nuclear Energy Unit, Malaysia

    International Nuclear Information System (INIS)

    Abdul Razak Daud

    1995-01-01

    One experiment was carried out to get the distribution of radiation doses at the neutron radiography facilities, Nuclear Energy Unit, Malaysia. The analysis was done to evaluate the safety level of the area. The analysis was used in neutron radiography work

  12. Construct a procedure to verify radiation protection for apparatus of industrial gamma radiography

    International Nuclear Information System (INIS)

    Nghiem Xuan Long; Trinh Dinh Truong; Dinh Chi Hung; Le Ngoc Hieu

    2013-01-01

    Apparatus for industrial gamma radiography include an exposure container, source guide tube, remote control hand crank assembly and other attached equipment. It is used a lot in inspection and evaluation of projects. In Vietnam, there are now more than 50 companies in radiography field and more than 100 apparatus are being used on the site. Therefore, the verification and evaluation is very necessary and important. This project constructs a procedure to verify a radiation protection for apparatus in the industrial gamma radiography for its application in Vietnam. (author)

  13. Findings of the inspection grading system on industrial radiography

    International Nuclear Information System (INIS)

    Gloria Doloressa

    2011-01-01

    The use of industrial radiography techniques evolve rapidly and widely. Various jobs in industry require the examination of welding techniques / connecting pipes and metal construction. The use of industrial radiography is one type of utilization of nuclear energy must get control so that its use does not cause harmful impacts to worker safety, community, and environment. Regulations is done through inspections, in order to supervise the observance of the terms in the licensing and legislation in the field of nuclear safety. The main purpose of inspection is to ensure the utilization of radiation sources of radiation have been used with. Findings of the inspection is a decline in the performance of licensees in meeting safety requirements. The Grading System to the findings of the inspection needs to be done to improve the effectiveness and efficiency of inspection, and it is expected that the company can improve the management of radiation safety. (author)

  14. NIF special equipment construction health and safety plan

    Energy Technology Data Exchange (ETDEWEB)

    Sawicki, R.H.

    1997-07-28

    The purpose of this plan is to identify how the construction and deployment activities of the National Ignition Facility (NIF) Special Equipment (SE) will be safely executed. This plan includes an identification of (1) the safety-related responsibilities of the SE people and their interaction with other organizations involved; (2) safety related requirements, policies, and documentation; (3) a list of the potential hazards unique to SE systems and the mechanisms that will be implemented to control them to acceptable levels; (4) a summary of Environmental Safety and Health (ES&H) training requirements; and (5) requirements of contractor safety plans that will be developed and used by all SE contractors participating in site activities. This plan is a subsidiary document to the NIF Construction Safety Program (CSP) and is intended to compliment the requirements stated therein with additional details specific to the safety needs of the SE construction-related activities. If a conflict arises between these two documents, the CSP will supersede. It is important to note that this plan does not list all of the potential hazards and their controls because the design and safety analysis process is still ongoing. Additional safety issues win be addressed in the Final Safety Analysis Report, Operational Safety Procedures (OSPs), and other plans and procedures as described in Section 3.0 of this plan.

  15. NIF special equipment construction health and safety plan

    International Nuclear Information System (INIS)

    Sawicki, R.H.

    1997-01-01

    The purpose of this plan is to identify how the construction and deployment activities of the National Ignition Facility (NIF) Special Equipment (SE) will be safely executed. This plan includes an identification of (1) the safety-related responsibilities of the SE people and their interaction with other organizations involved; (2) safety related requirements, policies, and documentation; (3) a list of the potential hazards unique to SE systems and the mechanisms that will be implemented to control them to acceptable levels; (4) a summary of Environmental Safety and Health (ES ampersand H) training requirements; and (5) requirements of contractor safety plans that will be developed and used by all SE contractors participating in site activities. This plan is a subsidiary document to the NIF Construction Safety Program (CSP) and is intended to compliment the requirements stated therein with additional details specific to the safety needs of the SE construction-related activities. If a conflict arises between these two documents, the CSP will supersede. It is important to note that this plan does not list all of the potential hazards and their controls because the design and safety analysis process is still ongoing. Additional safety issues win be addressed in the Final Safety Analysis Report, Operational Safety Procedures (OSPs), and other plans and procedures as described in Section 3.0 of this plan

  16. Configuration control during maintenance of safety related equipment

    International Nuclear Information System (INIS)

    Irish, C.S.

    2001-01-01

    Possibly the most important aspect of performing maintenance of safety related equipment is maintaining the component's original design basis. Assuring that the repaired item will perform the same safety function within the original performance and equipment qualification parameters is commonly referred to as configuration control. Maintaining configuration control of a technologically current well documented item is easy. Unfortunately, this does not describe most safety related items requiring maintenance within the global nuclear industry. Items such as motors, transformers, metal clad switchgear (low and medium voltage circuit breakers), refrigeration compressors, and electronic components (i.e. circuit boards, power supplies, regulators, etc.) which routinely require repair have been in service for twenty plus years. As a result, finding replacement parts and or material to repair the items to the original condition is becoming more and more difficult. An added difficulty is the lack of original technical documentation available on the item which is being repaired. The lack of technical documentation makes it difficult to identify replacement material and parts when the original part or material is not available. The lack of documentation also makes it difficult to test the repaired item to make sure that the original configuration has been maintained after the repair. The presentation will discuss the details of repairing various items including motors, metal clad switchgear, refrigeration compressors and power supplies and the controls which are necessary to maintain the configuration of the original item. The discussion will include the Quality Assurance and engineering necessary to identify and evaluate replacement material and parts necessary to perform repairs on safety related equipment when the original material or part is not available. Examples of repairs which required different parts or materials than the original to be used in the repair will be

  17. Configuration control during maintenance of safety related equipment

    International Nuclear Information System (INIS)

    Irish, C.S.

    2003-01-01

    Possibly the most important aspect of performing maintenance of safety related equipment is maintaining the component's original design basis. Assuring that the repaired item will perform the same safety function within the original performance and equipment qualification parameters is commonly referred to as configuration control. Maintaining configuration control of a technologically current well documented item is easy. Unfortunately, this does not describe most safety related items requiring maintenance within the global nuclear industry. Items such as motors, transformers, metal clad switchgear (low and medium voltage circuit breakers), refrigeration compressors, and electronic components (i.e. circuit boards, power supplies, regulators, etc.) which routinely require repair have been in service for twenty plus years. As a result, finding replacement parts and or material to repair the items to the original condition is becoming more and more difficult. An added difficulty is the lack of original technical documentation available on the item which is being repaired. The lack of technical documentation makes it difficult to identify replacement material and parts when the original part or material is not available. The lack of documentation also makes it difficult to test the repaired item to make sure that the original configuration has been maintained after the repair. The presentation will discuss the details of repairing various items including motors, metal clad switchgear, refrigeration compressors and power supplies and the controls which are necessary to maintain the configuration of the original item. The discussion will include the Quality Assurance and engineering necessary to identify and evaluate replacement material and parts necessary to perform repairs on safety related equipment when the original material or part is not available. Examples of repairs which required different parts or materials than the original to be used in the repair will be

  18. A study on enforcement effects of radiation safety control regulations for diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Sung, Mo IL; Park, Myeong Hwan; Kwon, Duk Moon; Lee, Joon IL

    1999-01-01

    The purposes of this study are to analyze the realities after enforcements of safety control regulations for diagnostic X-ray equipment and to suggest means for an improvement of low radiation safety control. A questionnaire survey for medical radiologic technologists was carried out to determine enforcement effects of the safety control regulations. The results of analysis from the survey are as follows. That is, most of he respondents realized the importance of the radiation safety control system, but about a half of them revealed that regulations were not well observed in accordance with their purposes. Only 43.9 percent of the respondents took an active part in quality control of radiation. And responsibility, sex, age, and knowledge for safety control were important indicators for observations of the regulations. Training for the safety control regulations are needed to ensure safety control and proper usage of diagnostic X-ray equipment. And management of organizations using diagnostic X-ray equipment have to understand and stress the importance of radiation safety control system. (author)

  19. Comparative study between computed radiography and conventional radiography

    International Nuclear Information System (INIS)

    Noorhazleena Azaman; Khairul Anuar Mohd Salleh; Sapizah Rahim; Shaharudin Sayuti; Arshad Yassin; Abdul Razak Hamzah

    2010-01-01

    In Industrial Radiography, there are many criteria that need to be considered based on established standards to accept or reject the radiographic film. For conventional radiography, we need to consider the optical density by using the densitometer when viewing the film on the viewer. But in the computed radiography (CR) we need to evaluate and performed the analysis from the quality of the digital image through grey value. There are many factors that affected the digital image quality. One of the factors which are affected to the digital image quality in the image processing is grey value that related to the contrast resolution. In this work, we performed grey value study measurement on digital radiography systems and compared it with exposed films in conventional radiography. The test sample is a steel step wedge. We found out the contrast resolution is higher in Computed Radiography compared with Conventional Radiography. (author)

  20. Engineering applications of microfocal radiography. Chapter 2

    International Nuclear Information System (INIS)

    Sharpe, R.S.; Parish, R.W.

    1980-01-01

    The engineering applications of microfocal radiography are reviewed in detail. After describing the terminology used, the types of application are identified where the advantages of the reduced focal spot size are utilised e.g. finer detail, dynamic radiography of temporally changing events, lower background in the film and superior depth of focus. The quality of the images obtained with microfocal techniques is also discussed in detail. Finally various types of microfocal equipment which are commercially available are described and explicit examples of the areas of application are given, e.g. non-destructive testing in the nuclear industry, microporosity in aero-engine gas turbine blades and inspection of miniaturised electronic components such as integrated circuits. (U.K.)

  1. Estimation of exposed radiation dose in radiography of the chest. Mainly on the dose at health examination on automobiles

    International Nuclear Information System (INIS)

    Suzuki, Shoichi; Oda, Akiko; Ohkura, Masaki

    1998-01-01

    The exposure doses in radiography and photofluorography of the chest at health examination on automobiles were estimated and compared with those using other hospital equipments. The tube voltage, effective energy and half value layer under ordinary conditions for radiography and fluorography were measured by KYOKKO model 100 X-ray analyzer and output pulse shape was confirmed by the fluorometer (TOREKEY-1001 C). The dose at the body surface was measured by the ionization chambers (VICTOREEN RADCON 500 and 30-330) which had been equipped in the WAC chest phantom (JIS Z 4915, Kyoto Kagaku). Nine automobiles of 3 facilities were used, of which X-ray generating apparatuses of either condenser or inverter type were manufactured by Hitachi (5 machines), Toshiba (1) and Shimadzu (3). The examined apparatuses not for the automobile were Toshiba-20 and Hitachi SIRIUS-100 portable ones and Hitachi DH-1520 TM high-voltage one. The effective energy was found dependent on the tube voltage (100-130 kV) and X-ray generating system (35.1-54.37 keV in the condenser type and 41.1-43.9 keV in the inverter type). Pulse shape analysis revealed that the pulse height and area under the pulse height-time curve were larger in the inverter system. The mean doses in photofluorography and radiography on automobiles were 0.525 and 0.297 mGy, respectively. The mean dose of 0.61 mGy in radiography at home with the portable apparatus was the highest even when compared with that of 0.525 mGy for fluorography on the automobile. Thus, the inverter system on the car can guarantee the level of 0.4 mGy defined by IAEA guideline (Safety series No. 115, 1996). (K.H.)

  2. Patient care in radiography

    International Nuclear Information System (INIS)

    Ehrlich, R.A.; McCloskey, E.D.

    1989-01-01

    This book focuses on patient care procedures for radiographers. The authors focus on the role of the radiographer as a member of the health care team. The authors report on such topics as communication in patient care: safety, medico-legal considerations, transfer and positioning; physical needs; infection control; medication; CPR standards, acute situations; examination of the GI tract; contrast media; special imaging techniques and bedside radiography

  3. Practical radiation protection for radiography

    International Nuclear Information System (INIS)

    Hubbard, S.K.; Proudfoot, E.A.

    1978-01-01

    Nondestructive Testing Applications and Radiological Engineering at the Hanford Engineering Development Laboratory have developed radiation protection procedures, radiation work procedures, and safe practice procedures to assure safe operation for all radiographic work. The following topics are discussed: training in radiation safety; radiation exposure due to operations at Hanford; safeguards employed in laboratory radiography; field radiographic operations; and problems

  4. Developments in digital radiography: an equipment update

    International Nuclear Information System (INIS)

    James, J.J.; O'Connor, P.J.; Davies, A.G.; Cowen, A.R.

    2001-01-01

    Digital X-ray imaging technology has advanced rapidly over the past few years. This review, particularly aimed at those involved in using and purchasing such technology, is an attempt to unravel some of the complexities of this potentially confusing subject. The main groups of X-ray imaging devices that are considered are digitisers of conventional radiographs, image-intensifier-based fluorography systems, photostimulable phosphor computed radiography, amorphous selenium-based technology for thorax imaging and flat-panel systems. As well as describing these different systems, we look at ways of objectively assessing their image quality. Concepts that are used and explained include spatial resolution, grey-scale bit resolution, signal-to-noise ratio and detective quantum efficiency. An understanding of these basic parameters is vital in making a scientific assessment of a system's performance. Image processing and techniques are also briefly discussed, particularly with reference to their potential effects on image quality. This review aims to provide a basic understanding of digital X-ray imaging technology and enables the reader to make an independent and educated assessment of the relative merits of each system. (orig.)

  5. A study on the scattered dose in portable chest radiography

    International Nuclear Information System (INIS)

    Ahn, Bong Seon; Lee, Hwan Hyung

    2000-01-01

    The purpose of this study is to survey the present status of portable radiography and the result of free space scattered dose rate when taking a radiography at the general hospital or the university hospital in Taejon city. The results were as follows; The number of cases using portable radiography for three years increased to averages 16.2%, 7.7% per year from January 1st in 1996 to December 31st in 1998. The average of distance of adjacent patients was 219.1 cm at the ward. For portable chest radiography, the free space scattered dose rate was 10.5 mSv/hr at 50 cm distance, 1.8 mSv/hr at 100 cm distance, and 0.2 mSv/hr at 200 cm distance. Therefore, in case of portable chest radiography at the ward, the average of distance of adjacent patients is 219.1 cm, so it dose not have influence on the adjacent patient. But during the portable radiography, a guardian who is close to the patient, doctor, nurse and radiologic technologists has to set up the shield to prevent from the unnecessary radiation or the distance should be as great as possible from the mobile X-ray equipment

  6. A methodology for radiological accidents analysis in industrial gamma radiography

    International Nuclear Information System (INIS)

    Silva, F.C.A. da.

    1990-01-01

    A critical review of 34 published severe radiological accidents in industrial gamma radiography, that happened in 15 countries, from 1960 to 1988, was performed. The most frequent causes, consequences and dose estimation methods were analysed, aiming to stablish better procedures of radiation safety and accidents analysis. The objective of this work is to elaborate a radiological accidents analysis methodology in industrial gamma radiography. The suggested methodology will enable professionals to determine the true causes of the event and to estimate the dose with a good certainty. The technical analytical tree, recommended by International Atomic Energy Agency to perform radiation protection and nuclear safety programs, was adopted in the elaboration of the suggested methodology. The viability of the use of the Electron Gamma Shower 4 Computer Code System to calculate the absorbed dose in radiological accidents in industrial gamma radiography, mainly at sup(192)Ir radioactive source handling situations was also studied. (author)

  7. Evaluation of safety requirements of erbium laser equipment used in dentistry

    International Nuclear Information System (INIS)

    Braga, Flavio Hamilton

    2002-01-01

    The erbium laser (Er:YAG) has been used in several therapeutic processes. Erbium lasers, however, operate with energies capable to produce lesions in biological tissues. Aiming the safe use, the commercialization of therapeutic laser equipment is controlled in Brazil, where the equipment should comply with quality and safety requirement prescribed in technical regulations. The objective of this work is to evaluate the quality and safety requirements of a commercial therapeutic erbium laser according to Brazilian regulations, and to discuss a risk control program intended to minimize the accidental exposition at dangerous laser radiation levels. It was verified that the analyzed laser can produce lesions in the skin and eyes, when exposed to laser radiation at distances smaller than 80 cm by 10 s or more. In these conditions, the use of protection glasses is recommended to the personnel that have access to the laser operation ambient. It was verified that the user's training and the presence of a target indicator are fundamental to avoid damages in the skin and buccal cavity. It was also verified that the knowledge and the correct use of the equipment safety devices, and the application of technical and administrative measures is efficient to minimize the risk of dangerous expositions to the laser radiation. (author)

  8. Development of protocols for corrosion and deposits evaluation in pipes by radiography

    International Nuclear Information System (INIS)

    2005-04-01

    The International Atomic Energy Agency is promoting industrial applications of non-destructive testing (NDT) technology, which includes radiography testing (RT) and related methods, to assure safety and reliability of operation of nuclear, petrochemical and other industrial facilities. In many industries such as petroleum, power stations, refineries, petrochemical and chemical plants, desalination pipelines and urban gas installations, the reliability and safety of equipment can be substantially influenced by degradation processes such as corrosion, erosion, deposits and blocking of pipes, which can seriously affect the security and consistency. One of the most important parameters in a piping or pipeline to be monitored and measured is the wall thickness. Among NDT methods, radiography has the advantage in that in the process of an inspection it eliminates the need for the costly removal of the pipe insulation and also the added benefit that it can be carried out in high temperature environments. The Coordinated Research Project (CRP) on Validation of Protocols for Corrosion and Deposits Determination in Small Diameter Pipes by Radiography (CORDEP) was implemented from 1997 to 2000 with the participation of 11 NDT laboratories from Algeria, China, Costa Rica, France, India, Republic of Korea, Malaysia, Sri Lanka, Syrian Arab Republic, Tunisia and Turkey. The CRP tested and validated radiographic measurement of corrosion and deposits in straight and bent pipes made of carbon or stainless steels corroded/eroded on the outer or inner surfaces with or without insulation. Each participating laboratory produced three test specimens of straight and bent pipes containing natural as well as simulated corrosion defects. Typical diameters of these pipes were up to 168 mm. Radiography using X ray machines and radioisotopes of Iridium-192 and Cobalt-60 in conjunction with radiographic film using single and double wall penetrations for total inspection was performed. Selected

  9. Radiological protection procedures for industrial applications of computed radiography; Procedimentos de protecao radiologica em aplicacoes industriais da radiografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Aquino, Josilto Oliveira de

    2009-03-15

    Due to its very particular characteristics, industrial radiography is responsible for roughly half of the relevant accidents in nuclear industry, in developed as well as in developing countries, according to the International Atomic Energy Agency (IAEA). Thus, safety and radiological protection in industrial gamma radiography have been receiving especial treatment by regulatory authorities of most Member States. The main objective of the present work was to evaluate, from the radioprotection point of view, the main advantages of computed radiography (CR) for filmless industrial radiography. In order to accomplish this, both techniques, i.e. conventional and filmless computed radiography were evaluated and compared through practical studies. After the studies performed at the present work it was concluded that computed radiography significantly reduces the inherent doses, reflecting in smaller restricted areas and costs, with consequent improvement in radiological protection and safety. (author)

  10. Aspects of safety assessments for package with additional equipment components

    International Nuclear Information System (INIS)

    Reiche, I.; Boerst, F.M.; Krietsch, T.

    2004-01-01

    Many paragraphs in TS-R-1 contain the terms ''package'' or ''packaging''. These terms are defined in TS-R-1 paras 230 and 231 and explained in TS-G-1.1 paras 230.1 - 230.6. The importance of a consistent understanding of these definitions has been shown by recent discussions during the assessment of applications for package design approval. There was disagreement, if equipment components attached to the container body during transport, e.g. a transport frame, should be considered part of the package and taken into account in the safety assessment for the package. Discussions were also caused by the way inner design components are treated in the safety assessment of the package. This paper summarises the regulatory requirements to such additional equipment components and presents the way of their inclusion into the package design approval process in Germany

  11. 26 CFR 1.187-1 - Amortization of certain coal mine safety equipment.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 3 2010-04-01 2010-04-01 false Amortization of certain coal mine safety... (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Itemized Deductions for Individuals and Corporations (continued) § 1.187-1 Amortization of certain coal mine safety equipment. (a) Allowance of deduction—(1) In...

  12. Synergistic behaviour of nuclear radiation, temperature-humidity extremes and LOCA situation on safety and safety-related equipment in Indian nuclear power plants

    International Nuclear Information System (INIS)

    Kulkarni, R.D.; Bora, J.S.; Prakash, Ravi; Agarwal, Vivek; Sundersingh, V.P.

    2002-01-01

    Full text: The general philosophy for the instrumentation in nuclear power plants is based on the use of equipment/instruments which are capable of continuous satisfactory operation over a long period of time with minimum attention. Long term reliability under varying service conditions is of prime importance. The reliability of nuclear power plant depends on the reliability of safety and safety-related electronic instruments/ equipment used for performing the crucial tasks. The electrical and electronic systems/ circuits/ components of the equipment used in reactor safety systems (e.g. reactor protection system, emergency core cooling system, etc.) and reactor safety-related systems (e.g. reactor containment isolation and cooling system, reactor shutdown system, etc.) are responsible for safe and reliable operation of a nuclear power plant. The performance of reactor safety and safety-related equipment/instruments viz. pressure and differential pressure transmitter, amplifier for ion chamber, etc. has been evaluated under synergistic atmosphere including LOCA to find out the critical link in the circuits and subsequent modifications are suggested. The mathematical representation of the generated database has been done to estimate the life span of the instruments and accordingly the guidelines has been prepared for the operational staff to avoid the forced outage of the plant. All the details are included and mathematical models are presented to predict the future performances

  13. Radiological safety of decayed source removal facility (DSRF) - an overview

    International Nuclear Information System (INIS)

    Rajput, Raksha; George, Jain Reji; Pathak, B.K.

    2018-01-01

    Industrial radiography is one of the major applications of radioisotope in engineering industry for Non-Destructive Testing (NDT). The equipment used for this purpose is called Industrial Radiography Exposure Device (IGRED) or radiography (RG) camera. In India, more than 1800 IGREDs including imported cameras are being used in NDT industry. These cameras are of different types and have various capacities to house different radioisotopes. Generally, 192 Ir sources are being used for NDT work. The sources are being supplied by BRIT to the users. After the useful period of the utilization of gamma intensity, the decayed source is returned to BRIT in RG camera. The decayed source is removed from the camera in the Decayed Source Removal Facility (DSRF). This facility serves the purpose of a miniature hot-cell with the capability of storing the decayed sources which are removed from the cameras. The empty camera is inspected for its mechanical functions and sent to BRIT's hot-cell for loading the new source. DSRF is situated at BRIT Vashi Complex. This paper deals with the radiological safety in the operation of DSRF for removing decayed sources from industrial radiography cameras

  14. A Handbook for Public Playground Safety. Volume II: Technical Guidelines for Equipment and Surfacing.

    Science.gov (United States)

    Consumer Product Safety Commission, Washington, DC.

    This handbook suggests safety guidelines for public playground equipment and describes various surfaces used under the equipment and possible injuries resulting from falls. The handbook is intended for use mainly by manufacturers, installers, school and park officials, and others interested in technical criteria for public playground equipment.…

  15. Pediatric digital radiography education for radiologic technologists: current state

    International Nuclear Information System (INIS)

    Morrison, Gregory; Culbertson, John; Carbonneau, Kira; John, Susan D.; Goske, Marilyn J.; Smith, Susan N.; Charkot, Ellen; Herrmann, Tracy

    2011-01-01

    Digital radiography (DR) is one of several new products that have changed our work processes from hard copy to digital formats. The transition from analog screen-film radiography to DR requires thorough user education because of differences in image production, processing, storage and evaluation between the forms of radiography. Without adequate education, radiologic technologists could unknowingly expose children to higher radiation doses than necessary for adequate radiograph quality. To evaluate knowledge about image quality and dose management in pediatric DR among radiologic technologists in the U.S. This communication describes a survey of 493 radiologic technologists who are members of the American Society of Radiologic Technologists (ASRT) and who evaluated the current state of radiological technologist education in image quality and dose management in pediatric DR. The survey included 23 survey questions regarding image acquisition issues, quality assurance, radiation exposure and education in DR of infants and children. Radiologic technologists express many needs in areas of training and education in pediatric DR. Suggested improvements include better tools for immediate feedback about image quality and exposure, more information about appropriate technique settings for pediatric patients, more user-friendly vendor manuals and educational materials, more reliable measures of radiation exposure to patients, and more regular and frequent follow-up by equipment vendors. There is a clear and widespread need for comprehensive and practical education in digital image technology for radiologic technologists, especially those engaged in pediatric radiography. The creation of better educational materials and training programs, and the continuation of educational opportunities will require a broad commitment from equipment manufacturers and vendors, educational institutions, pediatric radiology specialty organizations, and individual imaging specialists. (orig.)

  16. Chief objectives of the development of X-ray equipment engineering in Russia

    International Nuclear Information System (INIS)

    Blinov, N.N.; Varshavskij, Yu.V.; Zelikman, M.I.

    1997-01-01

    Based on the world tendencies in the development of X-ray diagnostic instruments the main problems int he development of domestic X-ray diagnostic equipment engineering are analyzed. Variant of basic equipment for modern X-ray room for digital biomedical radiography is proposed. Tendencies int he instrumentation of X-ray diagnosis are the following ones: X-ray computerized tomograph creation, development of telecontrolled X-ray computerized. complexes for biomedical X-ray complexes for digital biomedical radiography, automation of the film development

  17. Digital radiography detectors - A technical overview: Part 1

    International Nuclear Information System (INIS)

    Lanca, Luis; Silva, Augusto

    2009-01-01

    During the last two decades screen-film (SF) systems have been replaced by digital X-ray systems. The advent of digital technologies brought a number of digital solutions based on different detector and readout technologies. Improvements in technology allowed the development of new digital technologies for projection radiography such as computed radiography (CR) and digital radiography (DR). The large number of scientific papers concerning digital X-ray systems that have been published over the last 25 years indicates the relevance of these technologies in healthcare. There are important differences among different detector technologies that may affect system performance and image quality for diagnostic purposes. Radiographers are expected to have an effective understanding of digital X-ray technologies and a high level of knowledge and awareness concerning the capabilities of these systems. Patient safety and reliable diagnostic information are intrinsically linked to these factors. In this review article - which is the first of two parts - a global overview of the digital radiography systems (both CR and DR) currently available for clinical practice is provided

  18. Initial experiences in clinical application of the THORAX-FD: flat-panel detector radiography in thoracic diagnosis

    International Nuclear Information System (INIS)

    Herrmann, K.A.; Staebler, A.; Bonel, H.; Kulinna, C.; Holzknecht, N.; Reiser, M.F.; Geiger, B.; Boehm, S.; Maschke, M.

    2000-01-01

    The flat-panel detector closes the gap between radiography and the digital diagnostics equipment currently in use. In addition to the dose reduction that can be expected, the availability of diagnostic information in digital form enables the user to optimize the clinical workflow and to network radiography directly with a digital archiving and communication system. (orig.)

  19. Utilization and costs of lumbar and full spine radiography by Ontario chiropractors from 1994 to 2001.

    Science.gov (United States)

    Ammendolia, Carlo; Côté, Pierre; Hogg-Johnson, Sheilah; Bombardier, Claire

    2009-07-01

    In Ontario, chiropractors see one-third of patients who seek care for low back pain. Previous studies suggest that chiropractors have high utilization rates of lumbar and full spine radiography. There has been a proliferation of evidence-based guidelines recommending that plain film radiography be used only to assess high-risk patients with low back pain. Evidence for the use of full spine radiography, except for the evaluation of scoliosis is lacking. It is uncertain what impact the growing evidence against their use has had on radiography utilization by Ontario chiropractors. To describe the annual costs and use of lumbar and full spine plain film radiography among Ontario chiropractors between 1994 and 2001. Time-trend analysis of radiography utilization by Ontario chiropractors. Chiropractic claims data submitted to the Ontario Health Insurance Plan or the Workplace Safety & Insurance Board from 1994/1995 to 2000/2001. Change in the annual cost and proportion of claimants receiving lumbar and full spine radiography. Time-trend analysis of chiropractic claims submitted to the Ontario Health Insurance Plan (OHIP) or Workplace Safety & Insurance Board (WSIB) from 1994/1995 to 2000/2001 fiscal years. During the 7-year period, the proportion of OHIP claimants receiving lumbar spine radiography decreased from 4.54% to 3.25% and for full spine radiography from 3.87% to 3.04%. For WSIB claimants, lumbar spine radiography deceased from 6.49% to 3.30% of claimants and full spine radiography from 1.51% to 0.94%. OHIP payments for lumbar spine radiography decreased 12.7% to $562,944, whereas full spine radiography payments decreased 5.3% to $1,071,408. WSIB lumbar and full spine radiography payments decreased 44.2% and 34.3% to $31,202 and $11,713 respectively. Claims data from the two largest third-party payers of chiropractic services in Ontario, suggest that lumbar and full spine radiography, and their associated costs decreased steadily between 1994 and 2001.

  20. 46 CFR 31.40-10 - Cargo Ship Safety Equipment Certificate-T/ALL.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Cargo Ship Safety Equipment Certificate-T/ALL. 31.40-10 Section 31.40-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS INSPECTION AND CERTIFICATION Certificates Under International Convention for Safety of Life at Sea, 1974 § 31.40-10 Cargo Ship...

  1. Progress in digital radiography

    International Nuclear Information System (INIS)

    Cappelle, A.

    2016-01-01

    Because of its practical aspect digital radiography is more and more used in the industrial sector. There are 2 kinds of digital radiography. First, the 'computed radiography' that uses a photon-stimulated screen, and after radiation exposure this screen must be read by an analyser to get a digit image. The second type is the 'direct radiography' that allows one to get a digit radiograph of the object directly. Digital radiography uses the same radioactive nuclides as radiography with silver films: cobalt, iridium or selenium. The spatial resolution of digital radiography is less good than with classical silver film radiography but digital radiography offers a better visual contrast. (A.C.)

  2. The Information System on Occupational Exposure in Medicine, Industry and Research (ISEMIR): Industrial Radiography

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2014-08-15

    Industrial radiography work is often carried out under difficult working conditions, such as in confined spaces, in extreme cold or heat, or during the night. Working under such adverse conditions might result in operational situations in which occupational radiation protection may be compromised. Experience shows that incidents involving industrial radiography sources have sometimes resulted in high doses to workers, causing severe health consequences such as radiation burns and, in a few cases, death. It has been long known that there is significant potential for industrial radiography personnel to receive non-trivial occupational exposure. However, a global perspective is lacking, as is the availability of a systematic means for improving occupational radiation protection in industrial radiography worldwide. In 2006, the IAEA published IAEA Safety Standards Series No. SF-1, Fundamental Safety Principles, jointly sponsored by the European Atomic Energy Community, the Food and Agriculture Organization of the United Nations (FAO), the International Labour Organization (ILO), the International Maritime Organization, the OECD Nuclear Energy Agency (OECD/NEA), the Pan American Health Organization (PAHO), the United Nations Environment Programme (UNEP) and the World Health Organization (WHO). That publication sets out the fundamental safety objective and principles of protection and safety. In 2014, the IAEA published IAEA Safety Standards Series No. GSR Part 3, Radiation Protection and Safety of Radiation Sources: International Basic Safety Standards (the BSS), jointly sponsored by the European Commission, the FAO, the ILO, OECD/NEA, the PAHO, UNEP and the WHO. The BSS sets out the requirements that are designed to meet fundamental safety objectives and to apply the principles specified in IAEA Safety Standards Series No. SF-1. The establishment of safety requirements and provision of guidance on occupational radiation protection is a major component of the support

  3. The Information System on Occupational Exposure in Medicine, Industry and Research (ISEMIR): Industrial Radiography

    International Nuclear Information System (INIS)

    2014-08-01

    Industrial radiography work is often carried out under difficult working conditions, such as in confined spaces, in extreme cold or heat, or during the night. Working under such adverse conditions might result in operational situations in which occupational radiation protection may be compromised. Experience shows that incidents involving industrial radiography sources have sometimes resulted in high doses to workers, causing severe health consequences such as radiation burns and, in a few cases, death. It has been long known that there is significant potential for industrial radiography personnel to receive non-trivial occupational exposure. However, a global perspective is lacking, as is the availability of a systematic means for improving occupational radiation protection in industrial radiography worldwide. In 2006, the IAEA published IAEA Safety Standards Series No. SF-1, Fundamental Safety Principles, jointly sponsored by the European Atomic Energy Community, the Food and Agriculture Organization of the United Nations (FAO), the International Labour Organization (ILO), the International Maritime Organization, the OECD Nuclear Energy Agency (OECD/NEA), the Pan American Health Organization (PAHO), the United Nations Environment Programme (UNEP) and the World Health Organization (WHO). That publication sets out the fundamental safety objective and principles of protection and safety. In 2014, the IAEA published IAEA Safety Standards Series No. GSR Part 3, Radiation Protection and Safety of Radiation Sources: International Basic Safety Standards (the BSS), jointly sponsored by the European Commission, the FAO, the ILO, OECD/NEA, the PAHO, UNEP and the WHO. The BSS sets out the requirements that are designed to meet fundamental safety objectives and to apply the principles specified in IAEA Safety Standards Series No. SF-1. The establishment of safety requirements and provision of guidance on occupational radiation protection is a major component of the support

  4. Selection of equipment for equipment qualification

    International Nuclear Information System (INIS)

    Torr, K.G.

    1989-01-01

    This report describes the methodology applied in selecting equipment in the special safety systems for equipment qualification in the CANDU 600 MW nuclear generating stations at Gentilly 2 and Point Lepreau. Included is an explanation of the selection procedure adopted and the rationale behind the criteria used in identifying the equipment. The equipment items on the list have been grouped into three priority categories as a planning aid to AECB staff for a review of the qualification status of the special safety systems

  5. The basic discussion on nuclear power safety improvement based on nuclear equipment design

    International Nuclear Information System (INIS)

    Zhao Feiyun; Yao Yangui; Yu Hao; He Yinbiao; Gao Lei; Yao Weida

    2013-01-01

    The safety of strengthening nuclear power design was described based on nuclear equipment design after Fukushima nuclear accident. From these aspects, such as advanced standard system, advanced design method, suitable test means, consideration of beyond design basis event, and nuclear safety culture construction, the importance of nuclear safety improvement was emphatically presented. The enlightenment was given to nuclear power designer. (authors)

  6. Radiography – How do students understand the concept of radiography?

    International Nuclear Information System (INIS)

    Lundgren, S.M.; Lundén, M.; Andersson, B.T.

    2015-01-01

    Background: Radiography as a concept has mainly been associated with the functional role of the radiographer. The concept has been studied from a theoretical point of view. However, there is a lack of a theoretical foundation and research on the actual substance of the term radiography used in education. It is therefore important to undertake an investigation in order to determine how students after three years education understand the subject of radiography. Aim: The aim of this study was to analyse how students in the Swedish radiographers' degree program understand the concept of radiography. Method: A concept analysis was made according to the hybrid model, which combines theoretical, fieldwork and analytical phases. A summative content analysis was used to identify the number and content of statements. The empirical data were collected from questionnaires answered by radiography students at four universities in Sweden. Findings: All radiography students' exemplified radiography with statements related to the practical level although some of them also identified radiography at an abstract level, as a subject within a discipline. The attribute ‘An interdisciplinary area of knowledge’ emerged, which is an attribute on the abstract level. The practical level was described by four attributes: Mastering Medical Imaging’, ‘To accomplish images for diagnosis and interventions’, ‘Creating a caring environment’ and ‘Enabling fruitful encounters’. Conclusion: The hybrid model used was a versatile model of concept development. The results of this study have increased the understanding of what characterizes the concept of radiography in a Swedish context. - Highlights: • This concept analysis of radiography was undertaken according to a hybrid model. • In radiography humanistic aspects are emphasized, a shift from the technological perspective. • The attributes demonstrate the essence and interdisciplinary nature of radiography. • This

  7. Discussion on unpacking inspection of imported civil nuclear safety equipment

    International Nuclear Information System (INIS)

    Li Chan; Zhang Wenguang; Li Maolin; Li Shixin; Jin Gang; Yao Yuan

    2014-01-01

    This paper introduces the purpose, contents, process and requirements of unpacking inspection which is the second stage of safety inspection of imported civil nuclear safety equipment, expresses review key points on application documents of unpacking inspection, processes of witness on-the-spot before unpacking inspection outside the civil nuclear facilities by the test agency, discusses understanding of unpacking inspection, supervision of manufacture, inspection prior to shipment, supervision of loading and acceptance by the unit operating civil nuclear facilities, reports on unpacking inspection. Some suggestions on reinforcing the unpacking inspection in China are concerned. (authors)

  8. Industrial radiographies

    CERN Multimedia

    2005-01-01

    The Radiation Protection group wishes to remind CERN staff responsible for contractors performing X-ray inspections on the CERN sites that the firms must apply the legislation in force in their country of origin, in particular with regard to the prevention of risks relating to ionizing radiation. Industrial radiography firms called on to work on the CERN sites must also comply with the rules laid down in CERN's Radiation Safety Manual and be registered in the relevant CERN database. Since CERN is responsible for safety on its own site, a number of additional rules have been laid down for this kind of work, as set out in Radiation Protection Procedure PRP30 https://edms.cern.ch/file/346848/LAST_RELEASED/PRP30.pdf The CERN Staff Member responsible for the contract shall register the company and issue notification that an X-ray inspection is to be performed via the web interface at the following address: http://cern.ch/rp-radio

  9. Digital radiography

    International Nuclear Information System (INIS)

    Zani, M.L.

    2002-01-01

    X-ray radiography is a very common technique used to check the homogeneity of a material or the inside of a mechanical part. Generally the radiation that goes through the material to check, produced an image on a sensitized film. This method requires time because the film needs to be developed, digital radiography has no longer this inconvenient. In digital radiography the film is replaced by digital data and can be processed as any computer file. This new technique is promising but its main inconvenient is that today its resolution is not so good as that of film radiography. (A.C.)

  10. Technical evaluation of seismic qualification of safety-related equipment

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Yang Hui; Park, Heong Gee; Park, Yeong Seok [Univ. of Incheon, Incheon (Korea, Republic of)

    1994-04-15

    This study is purposed to evaluate the technical acceptability of the procedures and techniques of seismic qualifications which were performed for the YGN 3 and 4 safety-related equipment.This study is also targeted to suggest a systematized technical procedure guide for the effective performance and review of the seismic qualification, which reflects the most up-to-date licensing requirements and state-of the-art.

  11. Development of a Test Equipment for Performance Evaluation of Safety Systems

    International Nuclear Information System (INIS)

    Kim, S. J.; Kwon, S. M.; Lee, J. M.; Kim, C. K.; Cho, C. H.; Chun, J. H.; Park, M. K.

    2004-07-01

    The purpose of this study is to develop a test equipment for performance evaluation of safety systems in nuclear power plants. First, we develop an input-output simulator for reactor protection systems, ESF component control systems, and a data acquisition system for these I/O simulators as a hardware for this equipment. Then, we develop a software for human-machine interface system, which is easy-to-use and easy-to-modify. In addition, a simulation tool for a reactor trip switch gear is developed

  12. Neutron radiography applications in I.T.U. TRIGA Mark-II reactor

    International Nuclear Information System (INIS)

    Tugrul, A. B.

    2002-01-01

    Neutron radiography is an important radiographic technique which is supplied different and advanced information according to the X or gamma ray radiography. However, it has a trouble for supplying the convenient neutron sources. Tangential beam tube of Istanbul Technical University (ITU) TRIGA Mark-II Training and Research Reactor has been arranged for using neutron radiography. The neutron radiography set defined as detailed for the application of the technique. Two different techniques for neutron radiography are defined as namely, transfer method and direct method. For the transfer method dysprosium and indium screens are used in the study. But, dysprosium generally was preferred in many studies in the point of view nuclear safety. Gadolinium was used for direct method. Two techniques are compared and explained the preferring of the transfer technique. Firstly, reference composition is prepared for seeing the differences between neutron and X-ray or gamma radiography. In addition of it, some radiograph samples are given neutron and X-ray radiography which shows the different image characters. Lastly, some examples are given from archaeometric studies. One of them the brass plates of Great Mosque door in Cizre. After the neutron radiography application, organic dye traces are noticed. Other study is on a sword that belong to Urartu period at the first millennium B.C. It is seen that some wooden part on it. Some different artefacts are examined with neutron radiography from the Ikiztepe excavation site, then some animal post parts are recognized on them. One of them is sword and sheath which are corroded together. After the neutron radiography application, it can be noticed that there are a cloth between the sword and its sheath. By using neutron radiography, many interesting and detailed results are observed in ITU TRIGA Mark-II Training and Research Reactor. Some of them shouldn't be recognised by using any other technique

  13. Spent nuclear fuel project cold vacuum drying facility safety equipment list

    International Nuclear Information System (INIS)

    IRWIN, J.J.

    1999-01-01

    This document provides the safety equipment list (SEL) for the Cold Vacuum Drying Facility (CVDF). The SEL was prepared in accordance with the procedure for safety structures, systems, and components (SSCs) in HNF-PRO-516, ''Safety Structures, Systems, and Components,'' Revision 0 and HNF-PRO-097, Engineering Design and Evaluation, Revision 0. The SEL was developed in conjunction with HNF-SO-SNF-SAR-O02, Safety Analysis Report for the Cold Vacuum Drying Facility, Phase 2, Supporting Installation of Processing Systems (Garvin 1998). The SEL identifies the SSCs and their safety functions, the design basis accidents for which they are required to perform, the design criteria, codes and standards, and quality assurance requirements that are required for establishing the safety design basis of the SSCs. This SEL has been developed for the CVDF Phase 2 Safety Analysis Report (SAR) and shall be updated, expanded, and revised in accordance with future phases of the CVDF SAR until the CVDF final SAR is approved

  14. Development of ''SonialvisionSafireII'' system with a new digital radiography device

    International Nuclear Information System (INIS)

    Sano, Takayuki; Okumura, Takeshi; Sakai, Takihito; Fujiwara, Masashi; Toyoda, Toshihide

    2007-01-01

    We released the world's first X-TV system equipped with a 17 inch direct conversion type flat panel X-ray detector (FPD) ''Safire'' in an radiofrequency (RF) table in 2004. Our latest X-TV system, called SonialvisionSafireII, incorporates the digital radiography device and the high voltage generator both of which were newly developed to take better advantage of the characteristics of the FPD. The following are the features of the latest system: Image acquisition and processing with the original matrix of FPD (up to 2880 x 2880 matrix with a 17-inch field of view (FOV)), High-speed radiography in serial acquisition mode (up to 15 fps) and tomosynthesis acquisition mode (up to 30 fps), Operationally improved digital radiography device using a general-purpose personal computer. (author)

  15. 49 CFR 214.507 - Required safety equipment for new on-track roadway maintenance machines.

    Science.gov (United States)

    2010-10-01

    ... maintenance machines. 214.507 Section 214.507 Transportation Other Regulations Relating to Transportation... Roadway Maintenance Machines and Hi-Rail Vehicles § 214.507 Required safety equipment for new on-track roadway maintenance machines. (a) Each new on-track roadway maintenance machine shall be equipped with: (1...

  16. Evidence-based radiography

    International Nuclear Information System (INIS)

    Hafslund, Bjorg; Clare, Judith; Graverholt, Birgitte; Wammen Nortvedt, Monica

    2008-01-01

    Evidence-based practice (EBP) offers the integration of the best research evidence with clinical knowledge and expertise and patient values. EBP is a well known term in health care. This paper discusses the implementation of EBP into radiography and introduces the term evidence-based radiography. Evidence-based radiography is radiography informed and based on the combination of clinical expertise and the best available research-based evidence, patient preferences and resources available. In Norway, EBP in radiography is being debated and radiographers are discussing the challenges of implementing EBP in both academic and clinical practice. This discussion paper explains why EBP needs to be a basis for a radiography curriculum and a part of radiographers' practice. We argue that Norwegian radiographers must increase participation in research and developing practice within their specific radiographic domain

  17. Material & equipment, procurement & maintenance: Impact on blood safety.

    Science.gov (United States)

    Emmanuel, Jean C

    2010-01-01

    Blood Transfusion Safety is dependent on effectively organised and managed blood services, which have adequate financial resources, skilled manpower, appropriate infrastructure and quality management systems in place. 80% of the world's population has access to 20% of the supply blood products, of which little is consistently safe. HIV highlighted the importance of blood safety. The lack of effective blood services in low human development index (LHDI), developing countries, has lead to international funding and capacity building for more than three decades. The initial strategies focused on providing HIV testing reagents to prevention transmission, however this only addresses one part of blood safety. Blood safety is not only dependent on preventing HIV transmission. In many populations there are other infectious agents, which have a higher prevalence. Ensuring the correct blood is provided to the patient depends on: well managed services with effective leadership and adequate budgets; capacity building and retention of skilled experienced staff; availability of laboratory equipment, correctly maintained; blood cold chain systems; procedures for tendering, purchasing and ensuring an unbroken supply of reagents and consumables; and quality management systems. Barriers for simplified effective tendering, procurement and contracting require urgent attention and coordination of all funding organisations to ensure an unbroken supply of reagents. Copyright 2009. Published by Elsevier Ltd.

  18. Radiological incidents in industrial gamma radiography in the Philippines, 1979-1993

    International Nuclear Information System (INIS)

    Borras, A.M.

    1994-01-01

    Among the many practices of radiation sources, the practice of industrial gamma radiography in the country has the most number of reported radiological incidents. During the past fourteen (14) years, from 1979-1993, twenty (20) incidents that have occurred were reported to the Institute. This paper presents the nature and extent of the 20 reported incidents as well as the results of the analysis of why these incidents happened. The results of the analysis showed that the causes of these incidents are mainly human error and equipment failure. Hence, the factors that can minimize or prevent the chance of occurrence and/or recurrence of incidents and in minimizing the hazard in case of radiological incidents are: a) proper training and re-training of personnel; b) proper and regular inspection and maintenance of equipment; c) adequate radiation survey; and d) proper storage and inventory of the radiography sealed sources. (author). 3 refs.; 5 figs.; 1 tab

  19. Unresolved Safety Issue A-46 - seismic qualification of equipment in operating plants

    International Nuclear Information System (INIS)

    Anderson, N.

    1985-01-01

    Seismic Qualification of Equipment in Operating Plants was designated as an Unresolved Safety Issue (USI) in December, 1980. The USI A-46 program was developed in early 1981 to investigate the adequacy of mechanical and electrical equipment in operating plants to withstand a safe shutdown earthquake. The approach taken was to develop viable, cost effective alternatives to current seismic qualification licensing requirements which could be applied to operating nuclear power plants. The tasks investigated include: (1) identification of seismic sensitive systems and equipment; (2) assessment of adequacy of existing seismic qualification methods; (3) development and assessment of in-situ test procedures to assist in qualification of equipment; (4) seismic qualification of equipment using seismic experience data; and (5) development of methods to generate generic floor response spectra. Progress to date and plans for completion of resolution are reported

  20. Comparison of safety equipment between London underground and Beijing subway

    Science.gov (United States)

    Chen, T.; Zhang, S. Y.; Zhao, L. Z.; Xia, J. J.; Fu, X. C.; Bao, Z. M.; Chen, Y.; Zhang, X. Z.; Wang, R. J.; Hu, C.; Jing, L. S.; Wang, Y.

    2017-06-01

    The purpose of this paper was to improve the safety equipment’s effectiveness through the comparison. Firstly, the history and safety accident of London Underground and Beijing Subway were shown. Secondly, fire equipment between these two cities was compared including station’s hardware installations and carriage’s hardware installations. Thirdly, the relative software installations were also compared such as emergency drills. The results showed that Beijing Subway’s hardware installations were better than London. However, London Underground’s some installations were more effective than Beijing. Both cities would pay more attention on anti-terrorist in tunnel.

  1. Evaluation of Electrical Characteristics of Protective Equipment - a Prerequisite for Ensuring Safety and Health of Workers at Work

    Science.gov (United States)

    Buică, G.; Beiu, C.; Antonov, A.; Dobra, R.; Păsculescu, D.

    2017-06-01

    The protecting electrical equipment in use are subject to various factors generated by the use, maintenance, storage and working environment, which may change the characteristics of protection against electric shock. The study presents the results of research on the behaviour over time of protective characteristics of insulating covers of material of work equipment in use, in order to determine the type and periodicity of safety tests. There were tested and evaluated safety equipment with plastic and insulating rubber covers used in operations of verifying functionality, safety and maintenance of machinery used in manufacturing industries and specific services from electric, energy and food sector.

  2. Radiographic examination protocol and patient dose in lateral cephalometric radiography in Korea

    International Nuclear Information System (INIS)

    Choi, Jin Woo

    2010-01-01

    To survey the radiographic examination protocol for lateral cephalometric radiographic examinations and to measure their patient doses in Korea and to compare the dose according to the size of hospital, the type of image receptor system, and the installation duration. The radiographic examination protocols (kVp, mA, and exposure time) for lateral cephalometric radiography were surveyed with 61 cephalometric radiographic equipments and their patient dose-area product (DAP) measured with a DAP meter (DIAMENTOR M4-KDK, PTW, Freiburg, Germany) for 51 cephalometric radiographic equipments. The radiographic examination protocols and patient doses were compared according to the size of hospital (university dental hospital, dental hospital, and dental clinic), the type of image receptor system (film-based, DR and CR type) and the installation duration, respectively. SPSS 12.0.1 for Windows (SPSS Inc., Chicago, USA) was used for independent t-test and ANOVA test. The average protocols were 77.0 kVp, 12.7 mA, 6.2 second for cephalometric radiography. The average patient dose (DAP) was 128.0 mGy cm2 and 3rd quartile dose (DAP) 161.1 mGy cm2 for cephalometric radiography for adult male. There was no statistically significant difference at average patient DAP according to the size of hospital, the type of image receptor system, and the installation duration, respectively. The average patient dose was 128.0 mGy cm2 and the third quartile patient dose 161.1 mGy cm2 for lateral cephalometric radiography for adult male in Korea.

  3. Radiological security for industrial radiography

    International Nuclear Information System (INIS)

    Montoya G, Manuel.

    1985-04-01

    This report comprises the basic notions of nucleonics, simple calculations for point sources, X-rays, calculations for coatings, standards for radiation protection and industrial radiography instruments. The preceding sums up with the biological effects of ionizing radiation. This is a guide for people who wish to pass examinations, to get the license for radiological safety, for operators on gamma-graphic sources, which work in the country. It is a requirement for work with this kind of radioactive sources

  4. Developing a training program for radiation protection officers in industrial radiography

    International Nuclear Information System (INIS)

    Kinda, R.

    2013-04-01

    Non-Destructive Testing employs a variety of techniques which are used to test objects e.g. pipes, vessels, welded joints, castings and other devices for imperfections without interfering with their physical structure. The common methods of testing include magnetic particle, ultrasound, dye penetrant and industrial radiography using gamma emitting radiation sources and electronic x-ray emitting devices. Other methods used are acoustic emission testing, acoustic resonance testing, electromagnetic testing, infrared testing and leak testing. This project work focuses on training of RPOs in the areas where radiation is used, as improper use may lead to high radiation exposure. In order to ensure adequate protection and safety of staff and the public, the Radiation Protection Officers need to be thoroughly trained. With proper training the Radiation Protection Officer will have the ability to interpret legislative instruments and understand the requirements. The RPO will also be able to develop a Radiation Protection Plan and train fellow staff on radiation safety issues. A number of companies currently specialize in Industrial Radiography and this number is growing on a yearly basis. Since the increased use of radiation sources cannot be curbed, training Radiation Protection Officers will improve the radiation safety standards within these companies and promote the safe use of the radiation sources. Therefore this project covers the fundamental elements required to train Radiation Protection Officers in Industrial Radiography. (author)

  5. Fundamentals of a graded approach to safety-related equipment setpoints

    International Nuclear Information System (INIS)

    Woodruff, B.A.; Cash, J.S. Jr.; Bockhorst, R.M.

    1993-01-01

    The concept of using a graded approach to reconstitute instrument setpoints associated with safety-related equipment was first presented to the industry by the U.S. Nuclear Regulatory Commission during the 1992 ISA/POWID Symposium in Kansas City, Missouri. The graded approach establishes that the manner in which a utility analyzes and documents setpoints is related to each setpoint's relative importance to safety. This allows a utility to develop separate requirements for setpoints of varying levels of safety significance. A graded approach to setpoints is a viable strategy that minimizes extraneous effort expended in resolving difficult issues that arise when formal setpoint methodology is applied blindly to all setpoints. Close examination of setpoint methodology reveals that the application of a graded approach is fundamentally dependent on the analytical basis of each individual setpoint

  6. Method of operator safety assessment for underground mobile mining equipment

    Science.gov (United States)

    Działak, Paulina; Karliński, Jacek; Rusiński, Eugeniusz

    2018-01-01

    The paper presents a method of assessing the safety of operators of mobile mining equipment (MME), which is adapted to current and future geological and mining conditions. The authors focused on underground mines, with special consideration of copper mines (KGHM). As extraction reaches into deeper layers of the deposit it can activate natural hazards, which, thus far, have been considered unusual and whose range and intensity are different depending on the field of operation. One of the main hazards that affect work safety and can become the main barrier in the exploitation of deposits at greater depths is climate threat. The authors have analysed the phenomena which may impact the safety of MME operators, with consideration of accidents that have not yet been studied and are not covered by the current safety standards for this group of miners. An attempt was made to develop a method for assessing the safety of MME operators, which takes into account the mentioned natural hazards and which is adapted to current and future environmental conditions in underground mines.

  7. Method of operator safety assessment for underground mobile mining equipment

    Directory of Open Access Journals (Sweden)

    Działak Paulina

    2018-01-01

    Full Text Available The paper presents a method of assessing the safety of operators of mobile mining equipment (MME, which is adapted to current and future geological and mining conditions. The authors focused on underground mines, with special consideration of copper mines (KGHM. As extraction reaches into deeper layers of the deposit it can activate natural hazards, which, thus far, have been considered unusual and whose range and intensity are different depending on the field of operation. One of the main hazards that affect work safety and can become the main barrier in the exploitation of deposits at greater depths is climate threat. The authors have analysed the phenomena which may impact the safety of MME operators, with consideration of accidents that have not yet been studied and are not covered by the current safety standards for this group of miners. An attempt was made to develop a method for assessing the safety of MME operators, which takes into account the mentioned natural hazards and which is adapted to current and future environmental conditions in underground mines.

  8. Characterization and adjustment of the neutron radiography facility of the RP-10 nuclear reactor

    International Nuclear Information System (INIS)

    Ravello R, Y.R.

    2001-01-01

    The main aim of this work was to characterize and adjust the neutron radiography facility of the RP-10 nuclear reactor, and therefore be able to offer with this technique services to the industry and research centers in general. This technique will be complemented with others such as x-rays and gamma radiography. First, the shielding capacity of the facility was analyzed, proving that it complies with the radiological safety requirements established by the radiological safety code. Then gamma filtration tests were conducted in order to implement the direct method for image formation, optical density curves were built according to the thickness of the gamma filter, the type of film and the type of irradiation. Also, the indirect method for image formation was implemented for two types of converters: indium and dysprosium. Growth curves for optical density were also made according to contact time between converter-film, for different types of films. The resolution of the facility was also analyzed using two methods: Klasens (1946) and Harms (1986). Harms method came closer to the resolution of the human eye when compared to the Klasens method. Finally, the application fields of neutron radiography are presented, including those conducted at the neutron radiography facility of the RP-10 nuclear reactor. With this work, the RP-10 neutron radiography facility is ready to offer inspection and research services

  9. Practical evaluation of clinical image quality (4). Determination of image quality in digital radiography system

    International Nuclear Information System (INIS)

    Katayama, Reiji

    2016-01-01

    Recently, for medical imaging, digital radiography systems are widely used in clinical practices. However, a study in the past reported that a patient radiation exposure level by digital radiography is in fact not lower than that by analog radiography system. High level of attention needs to be paid for over-exposure when using the conventional analog radiography with a screen and a film, as it results in high density of the film. However, for digital radiography systems, since the automatic adjusting function of image density is equipped with them, no attention for radiation dose need to be paid. Thus technologists tend to be careless and results in higher chance for over-exposure. Current digital radiography systems are high-performance in the image properties and capable of patient dose reduction. Especially, the image quality of the flat panel detector system is recognized, higher than that of the computed radiography system by imaging plates, in both objective and subjective evaluations. Therefore, we technologists are responsible for optimizing the balance between the image quality of the digital radiogram and the radiation dose required for each case. Moreover, it is also required for us as medical technologists to make effective use of such evaluation result of medical images for patients. (author)

  10. Determination, through of thermoluminescence dosimetry, of the incident radiation in critical organs, during cephalometric radiographies

    International Nuclear Information System (INIS)

    Hipolito Junior, O. di; Goncalves, N.; Boscolo, F.N.; Montebelo Filho, A.

    1985-01-01

    The object of this paper was to value and to compare the doses of X-ray incident in critical orgas of patient and operator, during cephalometric radiography. Each patient was submited for two radiographics expositions. First of all, they use the followings factors: 85 kVp, 15 mA and 4/10 s of exposition; while of the second radiography the conditions were of 70 kVp, 15 mA and 1.2 s of exposition. The dosimetric method was the thermoluminescent through the LiF-700. Although the cephalometric radiographies showed similars qualities, in bot conditions where the equipment functioned, the situation of high voltage was noted small doses of radiation. (author) [pt

  11. Current radiography and tomography applications at Necsa and an envisaged upgrade towards a proposed South African national centre for radiography and tomography (SANCRAT)

    Energy Technology Data Exchange (ETDEWEB)

    Radebe, M.J.; De Beer, F.C. [Necsa - South African Nuclear Energy Corporation Limited, P. O.Box 582, Pretoria, 0001 (South Africa)

    2008-07-01

    An upgrade of the current Radiography and Tomography Research facilities is envisaged to enhance the group's support for Necsa's mission to undertake and support nuclear research and utilize penetrating radiation for the benefit of mankind. It is envisage that the SANCRAT will host neutron-, X-ray- and gamma ray penetrating radiation imaging infrastructures that can be utilized by researchers from industry as well as post graduate students from higher educational institutions. Modelling for the upgrade to a multifunctional neutron radiography and tomography facility has been underway. Upgrade plans and implementation has also begun for a 250 kV X-ray radiography set-up, that will exist independent from the neutron facility. Future expansion entails catering for a micro-focus X-ray -, and gamma ray radiography and tomography facilities. The current facilities available consist of one infrastructure facility based on two sources of penetrating radiation, i.e. SAFARI-1 research nuclear reactor as thermal neutron source and a 100 kV X-ray generator. This facility, which hosts the only operational neutron tomography R and D facility in the Southern Hemisphere and in Africa, are being extensively utilized by post graduate students and industry. The facility sees application in a wide range of scientific and engineering disciplines, amongst which is nuclear, geosciences, palaeontology, civil, mechanical, chemical, etc. This paper focus on case studies engaged at the current radiography and tomography facilities over the past 2 years as well as describing the envisaged upgrade initiatives to a fully equipped national centre. (authors)

  12. Current radiography and tomography applications at Necsa and an envisaged upgrade towards a proposed South African national centre for radiography and tomography (SANCRAT)

    International Nuclear Information System (INIS)

    Radebe, M.J.; De Beer, F.C.

    2008-01-01

    An upgrade of the current Radiography and Tomography Research facilities is envisaged to enhance the group's support for Necsa's mission to undertake and support nuclear research and utilize penetrating radiation for the benefit of mankind. It is envisage that the SANCRAT will host neutron-, X-ray- and gamma ray penetrating radiation imaging infrastructures that can be utilized by researchers from industry as well as post graduate students from higher educational institutions. Modelling for the upgrade to a multifunctional neutron radiography and tomography facility has been underway. Upgrade plans and implementation has also begun for a 250 kV X-ray radiography set-up, that will exist independent from the neutron facility. Future expansion entails catering for a micro-focus X-ray -, and gamma ray radiography and tomography facilities. The current facilities available consist of one infrastructure facility based on two sources of penetrating radiation, i.e. SAFARI-1 research nuclear reactor as thermal neutron source and a 100 kV X-ray generator. This facility, which hosts the only operational neutron tomography R and D facility in the Southern Hemisphere and in Africa, are being extensively utilized by post graduate students and industry. The facility sees application in a wide range of scientific and engineering disciplines, amongst which is nuclear, geosciences, palaeontology, civil, mechanical, chemical, etc. This paper focus on case studies engaged at the current radiography and tomography facilities over the past 2 years as well as describing the envisaged upgrade initiatives to a fully equipped national centre. (authors)

  13. X-ray equipment

    International Nuclear Information System (INIS)

    Redmayne, I.G.B.

    1988-01-01

    The patent concerns a warning and protection system for mobile x-ray equipment used for 'on site' radiography, so that workers in the vicinity of such a working unit can be alerted to its presence. The invention is a local repeater warning system which gives a preliminary warning that energisation of the tubehead is imminent, as well as a switch near the tubehead to abort or inhibit energisation. The latter switch allows personnel caught in the vicinity of the tubehead to prevent energisation. The preliminary warning may be flashing lamps or by a klaxon. The control unit for the equipment may include a monitoring circuit to detect failure of the warning light or klaxon. (U.K.)

  14. X-ray equipment

    Energy Technology Data Exchange (ETDEWEB)

    Redmayne, I.G.B.

    1988-01-06

    The patent concerns a warning and protection system for mobile x-ray equipment used for 'on site' radiography, so that workers in the vicinity of such a working unit can be alerted to its presence. The invention is a local repeater warning system which gives a preliminary warning that energisation of the tubehead is imminent, as well as a switch near the tubehead to abort or inhibit energisation. The latter switch allows personnel caught in the vicinity of the tubehead to prevent energisation. The preliminary warning may be flashing lamps or by a klaxon. The control unit for the equipment may include a monitoring circuit to detect failure of the warning light or klaxon. (U.K.).

  15. Neutron induced electron radiography; Radiografia com eletrons induzida por neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Marcos Leandro Garcia

    2008-07-01

    In the present paper a new radiography technique, the 'Neutron Induced Electron Radiography' - NIER, to inspect low thickness samples on the order of micra, has been developed. This technique makes use of low energy electrons as penetrating radiation generated from metallic gadolinium screens when irradiated by thermal neutrons. The conditions to obtain the best image for the conventional X-ray film Kodak-AA were determined by using a digital system to quantify the darkening level of the film. The irradiations have been performed at a radiography equipment installed at the beam-hole no. 8 of the 5 MW IEA-R1 nuclear research reactor of IPEN-CNEN/SP. The irradiation time to obtain the best radiography was 100 seconds and for such condition the technique was able to discern 1 {mu}m in 24 {mu}m of aluminum at a resolution of 32 {mu}m. By visual comparison the images obtained by the NIER shown a higher quality when compared with the ones from other usual techniques the make use of electrons a penetrating radiation and films for image registration. Furthermore the use of the digital system has provided a smaller time for data acquisition and data analysis as well as an improvement in the image visualization. (author)

  16. Digital luminescent radiography: A substitute for conventional chest radiography?

    International Nuclear Information System (INIS)

    Neufang, K.F.R.; Krug, B.; Lorenz, R.; Steinbrich, W.

    1990-01-01

    The image quality of digital luminescent radiography (DLR) is sufficient for routine biplane chest radiography and for follow-up studies of heart size, pulmonary congestion, coin lesions, infiltrations, atelectasis, pleural effusions, and mediastinal and hilar lymph node enlargement. Chest radiography in the intensive care unit may in most cases be performed using the DLR technique. there is no need for repeat shots because of incorrect exposure, and the position of catheters, tubes, pacemakers, drains and artificial heart valves, the mediastinum, and the retrocardiac areas of the left lung are more confidently assessed on the edge-enhanced DLR films than on conventional films. Nevertheless, DLR is somewhat inferior to conventional film-screen radiography of the chest as it can demonstrate or rule out subtle pulmonary interstitial disease less confidently. There is no reduction of radiation exposure of the chest in DLR compared with modern film-screen systems. As a consequence, DLR is presently not in a position to replace traditional film-screen radiography of the chest completely. (orig.) [de

  17. The Use of Digital Radiography in the Evaluation of Radioactive Materials. Packaging Performance Testing

    International Nuclear Information System (INIS)

    May, C; Lawrence Gelder, L; Boyd Howard, B

    2007-01-01

    New designs of radioactive material shipping packages are required to be evaluated in accordance with 10 CFR Part 71, ''Packaging and Transportation of Radioactive Material''. This paper will discuss the use of digital radiography to evaluate the effects of the tests required by 10 CFR 71.71, Normal Conditions of Transport (NCT), and 10 CFR 71.73, Hypothetical Accident Conditions (HAC). One acceptable means of evaluating packaging performance is to subject packagings to the series of NCT and HAC tests. The evaluation includes a determination of the effect on the packaging by the conditions and tests. That determination has required that packagings be cut and sectioned to learn the actual effects on internal components. Digital radiography permits the examination of internal packaging components without sectioning a package. This allows a single package to be subjected to a series of tests. After each test, the package is digitally radiographed and the effects of particular tests evaluated. Radiography reduces the number of packages required for testing and also reduces labor and materials required to section and evaluate numerous packages. This paper will include a description of the digital radiography equipment used in the testing and evaluation of the 9977 and 9978 packages at SRNL. The equipment is capable of making a single radiograph of a full-sized package in one exposure. Radiographs will be compared to sectioned packages that show actual conditions compared to radiographic images

  18. Safety plan for the cooperative telerobotic retrieval system equipment development area

    Energy Technology Data Exchange (ETDEWEB)

    Haney, T.J.; Jessmore, J.J.

    1995-07-01

    This plan establishes guidelines to minimize safety risks for the cooperative telerobotic retrieval project at the North Boulevard Annex (NBA). This plan has the dual purpose of minimizing safety risks to workers and visitors and of securing sensitive equipment from inadvertent damage by nonqualified personnel. This goal will be accomplished through physical control of work zones and through assigned responsibilities for project personnel. The scope of this plan is limited to establishing the working zone boundaries and entry requirements, and assigning responsibilities for project personnel. This plan does not supersede current safety organization responsibilities for the Landfill Stabilization Focus Area Transuranic (LSFA TRU) Arid outlined in the Environment, Safety, Health, and Quality Plan for the Buried Waste Integrated Demonstration Program; Tenant Manual; Idaho Falls Building Emergency Control Plan;; applicable Company Procedures; the attached Interface Agreement (Appendix A).

  19. Safety plan for the cooperative telerobotic retrieval system equipment development area

    International Nuclear Information System (INIS)

    Haney, T.J.; Jessmore, J.J.

    1995-07-01

    This plan establishes guidelines to minimize safety risks for the cooperative telerobotic retrieval project at the North Boulevard Annex (NBA). This plan has the dual purpose of minimizing safety risks to workers and visitors and of securing sensitive equipment from inadvertent damage by nonqualified personnel. This goal will be accomplished through physical control of work zones and through assigned responsibilities for project personnel. The scope of this plan is limited to establishing the working zone boundaries and entry requirements, and assigning responsibilities for project personnel. This plan does not supersede current safety organization responsibilities for the Landfill Stabilization Focus Area Transuranic (LSFA TRU) Arid outlined in the Environment, Safety, Health, and Quality Plan for the Buried Waste Integrated Demonstration Program; Tenant Manual; Idaho Falls Building Emergency Control Plan;; applicable Company Procedures; the attached Interface Agreement (Appendix A)

  20. Human performance analysis of industrial radiography radiation exposure events

    International Nuclear Information System (INIS)

    Reece, W.J.; Hill, S.G.

    1995-01-01

    A set of radiation overexposure event reports were reviewed as part of a program to examine human performance in industrial radiography for the US Nuclear Regulatory Commission. Incident records for a seven year period were retrieved from an event database. Ninety-five exposure events were initially categorized and sorted for further analysis. Descriptive models were applied to a subset of severe overexposure events. Modeling included: (1) operational sequence tables to outline the key human actions and interactions with equipment, (2) human reliability event trees, (3) an application of an information processing failures model, and (4) an extrapolated use of the error influences and effects diagram. Results of the modeling analyses provided insights into the industrial radiography task and suggested areas for further action and study to decrease overexposures

  1. Foetal radiography for suspected skeletal dysplasia: technique, normal appearances, diagnostic approach

    Energy Technology Data Exchange (ETDEWEB)

    Calder, Alistair D. [Great Ormond Street Hospital for Children NHS Foundation Trust, Radiology Department, London (United Kingdom); Offiah, Amaka C. [Sheffield Children' s NHS Foundation Trust, Academic Unit of Child Health, Sheffield (United Kingdom)

    2015-04-01

    Despite advances in antenatal imaging and genetic techniques, post-delivery post-mortem foetal radiography remains the key investigation in accurate diagnosis of skeletal dysplasia manifesting in the foetus. Foetal radiography is best performed using pathology-specimen radiography equipment and is often carried out in the pathology department without involvement of the radiology unit. However, paediatric radiologists may be asked to interpret post-mortem foetal radiographs when an abnormality is suspected. Many foetal radiographs are carried out before 20 weeks' gestation, and the interpreting radiologist needs to be familiar with the range of normal post-mortem foetal appearances at different gestational ages, as well as the appearances of some of the more commonly presenting skeletal dysplasias, and will benefit from a systematic approach when assessing more challenging cases. In this pictorial essay, we illustrate various normal post-mortem foetal radiographic appearances, give examples of commonly occurring skeletal dysplasias, and describe an approach to establishing more difficult diagnoses. (orig.)

  2. Foetal radiography for suspected skeletal dysplasia: technique, normal appearances, diagnostic approach

    International Nuclear Information System (INIS)

    Calder, Alistair D.; Offiah, Amaka C.

    2015-01-01

    Despite advances in antenatal imaging and genetic techniques, post-delivery post-mortem foetal radiography remains the key investigation in accurate diagnosis of skeletal dysplasia manifesting in the foetus. Foetal radiography is best performed using pathology-specimen radiography equipment and is often carried out in the pathology department without involvement of the radiology unit. However, paediatric radiologists may be asked to interpret post-mortem foetal radiographs when an abnormality is suspected. Many foetal radiographs are carried out before 20 weeks' gestation, and the interpreting radiologist needs to be familiar with the range of normal post-mortem foetal appearances at different gestational ages, as well as the appearances of some of the more commonly presenting skeletal dysplasias, and will benefit from a systematic approach when assessing more challenging cases. In this pictorial essay, we illustrate various normal post-mortem foetal radiographic appearances, give examples of commonly occurring skeletal dysplasias, and describe an approach to establishing more difficult diagnoses. (orig.)

  3. Technical basis for environmental qualification of microprocessor-based safety-related equipment in nuclear power plants

    International Nuclear Information System (INIS)

    Korsah, K.; Wood, R.T.; Hassan, M.; Tanaka, T.J.

    1998-01-01

    This document presents the results of studies sponsored by the Nuclear Regulatory Commission (NRC) to provide the technical basis for environmental qualification of computer-based safety equipment in nuclear power plants. The studies were conducted by Oak Ridge National Laboratory (ORNL), Sandia National Laboratories (SNL), and Brookhaven National Laboratory (BNL). The studies address the following: (1) adequacy of the present test methods for qualification of digital I and C systems; (2) preferred (i.e., Regulatory Guide-endorsed) standards; (3) recommended stressors to be included in the qualification process during type testing; (4) resolution of need for accelerated aging for equipment to be located in a benign environment; and (5) determination of an appropriate approach for addressing the impact of smoke in digital equipment qualification programs. Significant findings from the studies form the technical basis for a recommended approach to the environmental qualification of microprocessor-based safety-related equipment in nuclear power plants

  4. Technical basis for environmental qualification of microprocessor-based safety-related equipment in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Korsah, K.; Wood, R.T. [Oak Ridge National Lab., TN (United States); Hassan, M. [Brookhaven National Lab., Upton, NY (United States); Tanaka, T.J. [Sandia National Labs., Albuquerque, NM (United States)

    1998-01-01

    This document presents the results of studies sponsored by the Nuclear Regulatory Commission (NRC) to provide the technical basis for environmental qualification of computer-based safety equipment in nuclear power plants. The studies were conducted by Oak Ridge National Laboratory (ORNL), Sandia National Laboratories (SNL), and Brookhaven National Laboratory (BNL). The studies address the following: (1) adequacy of the present test methods for qualification of digital I and C systems; (2) preferred (i.e., Regulatory Guide-endorsed) standards; (3) recommended stressors to be included in the qualification process during type testing; (4) resolution of need for accelerated aging for equipment to be located in a benign environment; and (5) determination of an appropriate approach for addressing the impact of smoke in digital equipment qualification programs. Significant findings from the studies form the technical basis for a recommended approach to the environmental qualification of microprocessor-based safety-related equipment in nuclear power plants.

  5. Equipment line-up developed for structuring programmed digital systems important to safety

    International Nuclear Information System (INIS)

    Remus, L.; Colling, J.M.; Buisson, J.

    1986-01-01

    The use of the programmed digital techniques in systems important to safety led to developing equipment line-ups which allow to procedure, through using a restricted number of sub-assemblies, a variety of facilities capable of performing diversified functions. Upon remembering the requirements that such equipment are required to meet (quality assurance both at the design and production stages, qualification, testing opportunities, etc.) the equipments produced by MERLIN GERIN are described in this paper. Such equipments include a whole set of printed circuit boards, plug-in units with self-engaging connectors and the related cabinets to accomodate them. The following systems are made up of such equipments: Digital integrated protection system; Rod control and monitoring system; Reactor power distribution monitoring equipment. This equipment line-up has been gradually complemented and is still further expanding both as a result of the component further development or for the purpose of meeting new requirements or applications (new digital neutron instrumentation, local area networks). Experience gained thus far provides us with the capability of working out in a short time programmed systems for further applications in the nuclear power field

  6. Safety equipment and methods for evaluating its effectiveness

    Energy Technology Data Exchange (ETDEWEB)

    Evdokimov, F I; Nadtoka, T B [DPI (Ukraine)

    1993-05-01

    Analyzes relations between technologies (especially for roof support) used in black coal mining and work safety in mines. The share of manual work and accident rate are compared for mining by narrow and wide web shearer loaders and by coal plows with powered and individual support. Protection from occupational injury is discussed at three levels: safety engineering, work organization and the human factor. A method of evaluating the social and economic effectiveness of protection from occupational injury developed at the DPI institute is presented. The method uses the knowledge of probability distribution of failure situations, failures and protective means to determine the probabilistic characteristics of the functioning of protection systems and to calculate, for a given period, the occurrence probability and mean number of accidents. Each state of the system is characterized by determined social and/or economic results. The method was used in designing equipment intended for protective power cut-off in electric mine networks.

  7. Personnel exposures in industrial radiography

    International Nuclear Information System (INIS)

    Shenoy, K.S.; Patel, P.H.

    1979-01-01

    The manifold increase in production, and ease of availability of radioisotopes in India have been responsible for a tremendous increase in use of radioisotopes in industrial radiography during past fifteen years. Among various applications of radioisotopes the industrial radiography involves a large potential risk of occupational radiation exposures. The dose records of past fifteen years in respect of all radiation workers maintained by the Personnel Monitoring Group of Division of Radiological Protection of the Bhabha Atomic Research Centre, Bombay, have been analysed. Analysis of excessive exposure (exceeding 400 mrem/fortnight) reveals that this figure is increasing at an alarming rate among the radiation workers of this category. In spite of various regulatory controls the dose per person per week has remained higher as compared to the same in other categories. This combined with the increase in number of radiation workers every year would soon contribute significantly to the per capita dose for radiation workers. Use of adequately shielded fool-proof remote control equipment and training of all personnel in safe handling of radiation sources seem to be the only solution to arrest the rate of increase in personnel exposures of this category. (auth.)

  8. Charged Particle Radiography

    International Nuclear Information System (INIS)

    Morris, Chris

    2004-01-01

    The Coulomb multiple scattering of charged particles as they pass through material allows them to be used as a radiographic probe. This forms the basis for a new kind of radiography that is finding application where conventional x-ray radiography is limited by flux or backgrounds. Charged-particle radiography is providing a versatile new probe that has advantages over conventional x-ray radiography for some unique application. Proton radiography has been used to make quantitative motion pictures of high explosive driven experiments and proves to be of great value for radiographing experiments that mock up nuclear weapon primaries for stockpile certification. By taking advantage of magnetic lens to magnify images and by using the very bright beams that can be made with electrons, charged-particle radiography may be useful for studying the fine spatial detail and very fast motion in laser driven implosion experiments at the National Ignition Facility. Finally, radiographs can be made using cosmic-ray muons for searching vehicles and cargo containers for surreptitious cargo of high z materials such as uranium or plutonium.

  9. Industrial radiography

    International Nuclear Information System (INIS)

    1992-01-01

    Industrial radiography is a non-destructive testing (NDT) method which allows components to be examined for flaws without interfering with their usefulness. It is one of a number of inspection methods which are commonly used in industry to control the quality of manufactured products and to monitor their performance in service. Because of its involvement in organizing training courses in all the common NDT methods in regional projects in Asia and the Pacific and Latin America and the Caribbean and in many country programmes, the Agency is aware of the importance of standardizing as far as possible the syllabi and training course notes used by the many experts who are involved in presenting the training courses. IAEA-TECDOC-628 ''Training Guidelines in Non-destructive Testing'' presents syllabi which were developed by an Agency executed UNDP project in Latin America and the Caribbean taking into account the developmental work done by the International Committee for Non-destructive Testing. Experience gained from using the radiography syllabi from TECDOC-628 at national and regional radiography training courses in the Agency executed UNDP project in Asia and the Pacific (RAS/86/073) showed that some guidance needed to be given to radiography experts engaged in teaching at these courses on the material which should be covered. The IAEA/UNDP Asia and Pacific Project National NDT Coordinators therefore undertook to prepare Radiography Training Course Notes which could be used by experts to prepare lectures for Level 1,2 and 3 radiography personnel. The notes have been expanded to cover most topics in a more complete manner than that possible at a Level 1, 2 or 3 training course and can now be used as source material for NDT personnel interested in expanding their knowledge of radiography. Refs, figs and tabs

  10. Handling of radiation emergency involving accidental detachment of 20 Ci iridium-192 source in a guide tube of a radiographic equipment in industrial radiography site

    International Nuclear Information System (INIS)

    Zaparde, S.P.; Murthy, B.K.S.; Vora, V.B.; Subramanian, G.

    1979-01-01

    The source capsule containing about 17.2 Ci of iridium-192 got accidently unscrewed in a guide tube of a gamma radiography equipment while carrying out the radiography of the spiral casing at construction site of a Hydroelectric Power Station. Immediately after the incident about 10 meter distance all around the spiral casing was cordoned off. The unscrewed capsule along with the source pellet was transferred to a lead container by raising the closed end of the guide tube of about 1/2 meters in length. The source pencil cable and cap of source capsule were separated from the source pellet. The source pellet was further shielded by a steel container and lead sheets. The source pellet was reloaded in the source capsule with limited facilities available at the work site. The source capsule cap was perfectly screwed by standing behind the L bench temporarily constructed out of lead sheets for the above jobs. During the above operation, the person received a whole body dose of 2000 mR and extrimety dose of 3000 mR. Handling of one more radiation emergency of similar type is described. A few appliances designed and fabricated for use in such emergencies are briefly described. (auth.)

  11. Digital radiography: study of an alternative technique to conventional radiography

    International Nuclear Information System (INIS)

    Banchet, J.; Tisseur, D.; Thomas, A.

    2009-01-01

    Digital radiography, already in use in many industrial applications, appears as a potential alternative technique to conventional radiography in the nuclear field (and more especially to the inspection of welded joints). The advantages of digital radiography are a reduced explosion risk (due to the use of lower energy and activity sources), a lower installation time, a reduced exclusion zone, and the absence of effluents. However, to the contrary of the US case, this technique may not be used in France as it is not referenced in the regulating codes (RCCM, etc.). Areva has launched a R and D study in order to characterize the equivalencies between digital and conventional radiography. First results of this study are given

  12. Influence of lead apron shielding on absorbed doses from panoramic radiography.

    Science.gov (United States)

    Rottke, D; Grossekettler, L; Sawada, K; Poxleitner, P; Schulze, D

    2013-01-01

    This study investigated the absorbed doses in a full anthropomorphic body phantom from two different panoramic radiography devices, performing protocols with and without applying a lead apron. A RANDO(®) full body phantom (Alderson Research Laboratories Inc., Stamford, CT) was equipped with 110 thermoluminescent dosemeters at 55 different sites and set up in two different panoramic radiography devices [SCANORA(®) three-dimensional (3D) (SOREDEX, Tuusula, Finland) and ProMax(®) 3D (Planmeca, Helsinki, Finland)] and exposed. Two different protocols were performed in the two devices. The first protocol was performed without any lead shielding, whereas the phantom was equipped with a standard adult lead apron for the second protocol. A two-tailed paired samples t-test for the SCANORA 3D revealed that there is no difference between the protocol using lead apron shielding (m = 87.99, s = 102.98) and the protocol without shielding (m = 87.34, s = 107.49), t(54) = -0.313, p > 0.05. The same test for the ProMax 3D showed that there is also no difference between the protocol using shielding (m = 106.48, s = 117.38) and the protocol without shielding (m = 107.75, s = 114,36), t(54) = 0.938, p > 0.05. In conclusion, the results of this study showed no statistically significant differences between a panoramic radiography with or without the use of lead apron shielding.

  13. Neutron radiography, techniques and applications

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1987-10-01

    After describing the principles of the ''in pool'' and ''dry'' installations, techniques used in neutron radiography are reviewed. Use of converter foils with silver halide films for the direct and transfer methods is described. Advantages of the use of nitrocellulose film for radiographying radioactive objects are discussed. Dynamic imaging is shortly reviewed. Standardization in the field of neutron radiography (ASTM and Euratom Neutron Radiography Working Group) is described. The paper reviews main fields of use of neutron radiography. Possibilities of use of neutron radiography at research reactors in various scientific, industrial and other fields are mentioned. Examples are given of application of neutron radiography in industry and the nuclear field. (author)

  14. Basic principles of industrial radiography

    International Nuclear Information System (INIS)

    Bestbier, P.

    1983-01-01

    X-ray radiography and gamma radiography are used in industrial radiography. X-rays and gamma rays have the ability to penetrate materials and be absorbed by different densities. This characteristic makes them useful tools in industrial and medical radiography. The sources used for the generation of x-rays, gamma rays and radioisotopes are discussed. Films are one of the recording methods of x-radiography. The article also deals with advantages and disadvantages of radiography. Factors governing radiation exposure includes: the type of radiation source, material to be radiographed, distance, film, and the method for development. International specifications are also responsible for strict control over the standard of workmanship in industrial radiography

  15. Radiological equipment analyzed by specific developed phantoms and software

    International Nuclear Information System (INIS)

    Soto, M.; Campayo, J. M.; Mayo, P.; Verdu, G.; Rodenas, F.

    2010-10-01

    The use of radiographic phantoms specifically designed to evaluate the operation of the radiographic equipment lets the study of the image quality obtained by this equipment in an objective way. In digital radiographic equipment, the analysis of the image quality can be computerized because the acquisition of the image is possible in different technologies that are, computerized radiography or phosphor plate and direct radiography or detector. In case of film-screen equipment s this analysis could be applied digitalising the image in a professional scanner. In this work we have shown an application to assess automatically the constancy quality image in the image chain of the radiographic equipment s. This application is integrated by designed radiographic phantoms which are adapted to conventional, dental equipment s and specific developed software for the automatic evaluation of the phantom image quality. The software is based on digital image processing techniques that let the automatic detection of the different phantom tests by edge detector, morphological operators, threshold histogram techniques... etc. The utility developed is enough sensitive to the radiographic equipment of operating conditions of voltage (kV) and charge (m As). It is a friendly user programme connected with a data base of the hospital or clinic where it has been used. After the phantom image processing the user can obtain an inform with a resume of the imaging system state with accepting and constancy results. (Author)

  16. Radiological equipment analyzed by specific developed phantoms and software

    Energy Technology Data Exchange (ETDEWEB)

    Soto, M.; Campayo, J. M. [Logistica y Acondicionamientos Industriales SAU, Sorolla Center, Local 10, Av. de las Cortes Valencianas No. 58, 46015 Valencia (Spain); Mayo, P. [TITANIA Servicios Tecnologicos SL, Sorolla Center, Local 10, Av. de las Cortes Valencianas No. 58, 46015 Valencia (Spain); Verdu, G.; Rodenas, F., E-mail: m.soto@lainsa.co [ISIRYIM Universidad Politecnica de Valencia, Camino de Vera s/n, Valencia (Spain)

    2010-10-15

    The use of radiographic phantoms specifically designed to evaluate the operation of the radiographic equipment lets the study of the image quality obtained by this equipment in an objective way. In digital radiographic equipment, the analysis of the image quality can be computerized because the acquisition of the image is possible in different technologies that are, computerized radiography or phosphor plate and direct radiography or detector. In case of film-screen equipment s this analysis could be applied digitalising the image in a professional scanner. In this work we have shown an application to assess automatically the constancy quality image in the image chain of the radiographic equipment s. This application is integrated by designed radiographic phantoms which are adapted to conventional, dental equipment s and specific developed software for the automatic evaluation of the phantom image quality. The software is based on digital image processing techniques that let the automatic detection of the different phantom tests by edge detector, morphological operators, threshold histogram techniques... etc. The utility developed is enough sensitive to the radiographic equipment of operating conditions of voltage (kV) and charge (m As). It is a friendly user programme connected with a data base of the hospital or clinic where it has been used. After the phantom image processing the user can obtain an inform with a resume of the imaging system state with accepting and constancy results. (Author)

  17. Identifying high dose activities in industrial site radiography

    International Nuclear Information System (INIS)

    Heaton, B.

    2000-01-01

    Although the radiation doses received by industrial radiographers in the UK have progressively fallen over the last few years, with most now receiving less than 1 mSv/y, a few still receive, relative to the rest, much higher doses. As a percentage of all radiographers the number stays surprisingly constant from year to year. This paper describes a survey to identify the work causing these doses and suggest possible solutions. The UK Central Index of Dose Information was interrogated to identify the industrial radiography companies having staff (not necessarily the same person) with doses of greater than 5mSv/y in the last three years for which information was available. This was 15 in total. The people on the staff receiving these doses were identified and a questionnaire sent to the companies concerned requesting information about their work. A general questionnaire about the operation of the company was also included. With the agreement of the company these questionnaires were followed up by a visit to the company to interviews a number of the management and the radiographers if available. Both groups were generally very open about their problems and every discussion had a positive outcome. Several areas of work/reasons for the doses have been identified. These are: pipeline radiography, ultra sound radiographers working on nuclear reactors, complex plant work often with several teams in the area, inability to retreat from the wind out equipment due to height or access problems, site pressure to not follow the best practices and a lack of appreciation when a dose was being received or, alternatively, carelessness. Some o these problem areas are very difficult to resolve. However ways in which the Health and Safety can help influence the doses have been identified together with practical suggestions radiographers could adopt. These will be reported. (author)

  18. Considerations concerning the reliability of reactor safety equipment

    International Nuclear Information System (INIS)

    Furet, J.; Guyot, Ch.

    1967-01-01

    A review is made of the circumstances which favor a good collection of maintenance data at the C.E.A. The large amount of data to be treated has made necessary the use of a computer for analyzing automatically the results collected. Here, only particular aspects of the reliability from the point of view of the electronics used for nuclear reactor control will be dealt with: sale and unsafe failures; probability of survival (in the case of reactor safety); availability. The general diagrams of the safety assemblies which have been drawn up for two types of reactor (power reactor and low power experimental reactor) are given. Results are presented of reliability analysis which could be applied to the use of functional modular elements, developed industrially in France. Improvement of this reliability appears to be fairly limited by an increase in the redundancy; on the other hand it is shown how it may be very markedly improved by the use of automatic tests with different frequencies for detecting unsafe failures rates of measurements for the sub-assemblies and for the logic sub-assemblies. Finally examples are given to show the incidence of the complexity and of the use of different technologies in reactor safety equipment on the reliability. (authors) [fr

  19. Regulatory analysis for resolution of Unresolved Safety Issue A-46, seismic qualification of equipment in operating plants

    International Nuclear Information System (INIS)

    Chang, T.Y.; Anderson, N.R.

    1987-02-01

    The margin of safety provided in existing nuclear power plant equipment to resist seismically induced loads and perform required safety functions may vary considerably, because of significant changes in design criteria and methods for the seismic qualification of equipment over the years. Therefore, the seismic qualification of equipment in operating plants must be reassessed to determine whether requalification is necessary. The objective of technical studies performed under Task Action Plan A-46 was to establish an explicit set of guidelines and acceptance criteria to judge the adequacy of equipment under seismic loading at all operating plants, in lieu of requiring these plants to meet the criteria that are applied to new plants. This report presents the regulatory analysis for Unresolved Safety Issue (USI) A-46. It includes: Statement of the Problem; the Objective of USI A-46; a Summary of A-46 Tasks; a Proposed Implementation Procedure; a Value-Impact Analysis; Application of the Backfit Rule; 10 CFR 50.109; Implementation; and Operating Plants To Be Reviewed to USI A-46 Requirements

  20. Study on a quantitative evaluation method of equipment maintenance level and plant safety level for giant complex plant system

    International Nuclear Information System (INIS)

    Aoki, Takayuki

    2010-01-01

    In this study, a quantitative method on maintenance level which is determined by the two factors, maintenance plan and field work implementation ability by maintenance crew is discussed. And also a quantitative evaluation method on safety level for giant complex plant system is discussed. As a result of consideration, the following results were obtained. (1) It was considered that equipment condition after maintenance work was determined by the two factors, maintenance plan and field work implementation ability possessed by maintenance crew. The equipment condition determined by the two factors was named as 'equipment maintenance level' and its quantitative evaluation method was clarified. (2) It was considered that CDF in a nuclear power plant, evaluated by using a failure rate counting the above maintenance level was quite different from CDF evaluated by using existing failure rates including a safety margin. Then, the former CDF was named as 'plant safety level' of plant system and its quantitative evaluation method was clarified. (3) Enhancing equipment maintenance level means an improvement of maintenance quality. That results in the enhancement of plant safety level. Therefore, plant safety level should be always watched as a plant performance indicator. (author)

  1. Specific radiography technique

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    Beside radiography testing using x-ray machine and gamma source, there are several technique that developed specifically to complete the testing that cannot be done with the two earlier. This technique was specific based on several factor, for the example, the advantages of neutron and electron using to show the image was unique compare to x-ray and gamma. Besides that, these special radiography techniques maybe differ in how to detect the radiation get through the object. These technique can used to inspect thin or specimen that contained radioactive material. There are several technique will discussed in this chapter such as neutron radiography, electron radiography, fluoroscopy and also autoradiography.

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive medical ...

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small dose ... limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is ...

  4. Bone X-Ray (Radiography)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  5. Technical diagnostics - equipment monitoring for increasing safety and availability of nuclear power plants

    International Nuclear Information System (INIS)

    Sturm, A.; Foerster, R.

    1977-01-01

    Utilization of technical diagnostics in equipment monitoring of nuclear power plants for ensuring nuclear safety, economic availability, and for decision making on necessary maintenance is reviewed. Technical diagnostics is subdivided into inspection and early detection of malfunctions. Moreover, combination of technical diagnostics and equipment monitoring, integration of technical diagnostics into maintenance strategy, and problems of introducing early detection of malfunctions into maintenance management of nuclear power plants are also discussed. In addition, a compilation of measuring techniques used in technical diagnostics has been made. The international state of the art of equipment monitoring in PWR nuclear power plants is illustrated by description of the sound and vibration measuring techniques. (author)

  6. Digital radiography

    International Nuclear Information System (INIS)

    Kusano, Shoichi

    1993-01-01

    Firstly, from an historic point of view, fundamental concepts on digital imaging were reviewed to provide a foundation for discussion of digital radiography. Secondly, this review summarized the results of ongoing research in computed radiography that replaces the conventional film-screen system with a photo-stimulable phosphor plate; and thirdly, image quality, radiation protection, and image processing techniques were discussed with emphasis on picture archiving and communication system environment as our final goal. Finally, future expansion of digital radiography was described based on the present utilization of computed tomography at the National Defense Medical College Hospital. (author) 60 refs

  7. Analysis for making a regulatory decision to equipment of industrial gammagraphy in Argentin; Analisis para la toma de decision regulatoria sobre equipos de gammagrafia industrial en Argentina

    Energy Technology Data Exchange (ETDEWEB)

    Ermacora, Marcela G.; Vidal, Dora N.; Alonso, Maria T., E-mail: mermacora@arn.gob.ar, E-mail: dvidal@arn.gob.ar, E-mail: malonso@arn.gob.ar [Autoridad Regulatoria Nuclear (ARN), Buenos Aires (Argentina)

    2013-10-01

    Industrial gammagraphy is a practice widely used as a nondestructive testing technique in Argentina. Experience worldwide has shown the need for an improvement in the intrinsic safety of the equipment used in this lab. In response to this reason, the board of the Nuclear Regulatory Authority (ARN) has considered a proposal to withdraw service movement and much of the equipment inventory scan belonging to industrial facilities nationwide. The main objective of this paper is to present the results of the analysis performed to support the above proposal. The main elements of evaluation can be summarized as follows: I) the teams that do not conform to international recommendations regarding compliance with key safety requirements of international standards such as ISO 3999:2004 (E) {sup R}adiation protection - Industrial Apparatus for gamma radiography - Specifications for performance, design and tests {sup ;} II) the decision by some manufacturers to discontinue production of certain models of equipment and the provision of spare parts, and III) the validity of certificates bulk type B (U) for transport. In conclusion, it highlights the importance of a regulatory decision supplementary to the Standard AR 7.9.1 concerning the operation of scan equipment industry, based on current international recommendations and Argentina's commitment to good practice and safety culture which can lead to a positive impact on radiation safety in this art.

  8. Radiography - A conceptual approach

    Energy Technology Data Exchange (ETDEWEB)

    Ahonen, Sanna-Mari [Department of Nursing Science and Health Administration, University of Oulu, P.O. Box 5000, FIN-90014 (Finland)], E-mail: sanna-mari.ahonen@oulu.fi

    2008-11-15

    Aim: The purpose of this article is to describe interdisciplinary comparison of the attributes of the concept of radiography in health sciences, physics and technology on the grounds of concept analysis. Background: The concept of radiography is widely used in health sciences, physics and technology. However, the content of the concept may vary. In order to clarify the concept of radiography, the concept must be systematically examined and defined in linguistic form. Method: The concept of radiography was analysed by using the evolutionary method of concept analysis. The data were collected through discretionary sampling and consisted of literature and Internet pages. Qualitative content analysis was employed for analysing the data. Findings: As a result of concept analysis, the concept of radiography in health sciences was determined as expertise of radiographers in the use of radiation, which is dual, dynamic, social and situation-related in nature, and typically based on versatile synthesis. Regarding the attributes identified, the concept of radiography has both similarities and differences between health sciences, physics and technology. Conclusions: The concept of radiography was found to be more abstract, wider, more complex and more radiographer-centred in health sciences than in other disciplines. The content of the concept of radiography seems to vary according to the discipline.

  9. Radiography - A conceptual approach

    International Nuclear Information System (INIS)

    Ahonen, Sanna-Mari

    2008-01-01

    Aim: The purpose of this article is to describe interdisciplinary comparison of the attributes of the concept of radiography in health sciences, physics and technology on the grounds of concept analysis. Background: The concept of radiography is widely used in health sciences, physics and technology. However, the content of the concept may vary. In order to clarify the concept of radiography, the concept must be systematically examined and defined in linguistic form. Method: The concept of radiography was analysed by using the evolutionary method of concept analysis. The data were collected through discretionary sampling and consisted of literature and Internet pages. Qualitative content analysis was employed for analysing the data. Findings: As a result of concept analysis, the concept of radiography in health sciences was determined as expertise of radiographers in the use of radiation, which is dual, dynamic, social and situation-related in nature, and typically based on versatile synthesis. Regarding the attributes identified, the concept of radiography has both similarities and differences between health sciences, physics and technology. Conclusions: The concept of radiography was found to be more abstract, wider, more complex and more radiographer-centred in health sciences than in other disciplines. The content of the concept of radiography seems to vary according to the discipline

  10. Tl dosimetry around equipment s for dental radiography

    International Nuclear Information System (INIS)

    Medrano, E.; Robles G, M. A.; Vega C, H. R.; Letechipia de L, C.; Hernandez D, V. M.

    2014-08-01

    The ambient dose equivalent around X-rays units used in dentistry has been measured. The radiation that escapes of the tail stock of the X-rays equipment was also measured, and the dose in the surfaces of a polyethylene spherical mannequin and other of water, used to represent the patient and the operator, respectively. The study was realized with thermoluminescent dosimeters of the type 100. The operation conditions of the X-rays units were varied when the ambient dose equivalent was measured. In the other measurements the equipment s were operated to 70 k Vp and 8 m A. In the ambient dose equivalent was found asymmetry, likewise the due dose to the radiation that escapes of one of tail stocks was also asymmetric. The dose values in the mannequins went minors to the recommended reference values. (Author)

  11. IE Information Notice No. 85-08: Industry experience on certain materials used in safety-related equipment

    International Nuclear Information System (INIS)

    Jordan, E.L.

    1992-01-01

    This information notice is being issued to provide licensees and construction permit holders with information pertaining to the behavior of certain materials used in safety-related equipment. The materials, as described below, were observed to have the potential of degrading the operability of safety-related equipment. These observations were made during environmental qualification testing and/or during routine inspection of in-service equipment. The notice describes the following: elastomeric seals used in personnel air locks for the reactor containment systems; epoxy phenolic coating applied to the lower portion of the interior surface of diesel oil storage tanks; the use of Viton elastomer as the seal material in hydrogen recombiner applications; and environmental qualification of ASCO NP valves with Viton and ethylene propylene parts

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  13. A radiological health study of industrial gamma radiography in Canada

    International Nuclear Information System (INIS)

    1979-05-01

    As an occupational group, industrial radiographers receive radiation doses second only to reactor workers. This report is a result of a study carried out to research the causes for this relatively high dose and determine if and how it can be improved. The data presented herein were obtained from questionnaires and field visits to organizations involved in gamma radiography and from the Canadian National Dose Registry. Some applications of radiography such as pipeline work give rise to higher than average doses. When all safety measures are conscientiously aplied, the doses are reasonalbe. However, ignorance, carelessness and indifference account for much unnecessary exposure to radiation. (Auth)

  14. A Study on Performance and Safety Tests of Electrosurgical Equipment.

    Science.gov (United States)

    Tavakoli Golpaygani, A; Movahedi, M M; Reza, M

    2016-09-01

    Modern medicine employs a wide variety of instruments with different physiological effects and measurements. Periodic verifications are routinely used in legal metrology for industrial measuring instruments. The correct operation of electrosurgical generators is essential to ensure patient's safety and management of the risks associated with the use of high and low frequency electrical currents on human body. The metrological reliability of 20 electrosurgical equipment in six hospitals (3 private and 3 public) was evaluated in one of the provinces of Iran according to international and national standards. The achieved results show that HF leakage current of ground-referenced generators are more than isolated generators and the power analysis of only eight units delivered acceptable output values and the precision in the output power measurements was low. Results indicate a need for new and severe regulations on periodic performance verifications and medical equipment quality control program especially in high risk instruments. It is also necessary to provide training courses for operating staff in the field of meterology in medicine to be acquianted with critical parameters to get accuracy results with operation room equipment.

  15. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  16. Specific developed phantoms and software to assess radiological equipment image quality

    International Nuclear Information System (INIS)

    Verdu, G.; Rodenas, F.

    2011-01-01

    The use of radiographic phantoms specifically designed to evaluate the operation of the radiographic equipment lets the study of the image quality obtained by this equipment in an objective way. In digital radiographic equipment, the analysis of the image quality can be automatized because the acquisition of the image is possible in different technologies that are, computerized radiography or phosphor plate and direct radiography or detector. In this work we have shown an application to assess automatically the constancy quality image in the image chain of the radiographic equipment. This application is integrated by designed radiographic phantoms which are adapted to conventional, dental equipment and specific developed software for the automatic evaluation of the phantom image quality. The software is based on digital image processing techniques that let the automatic detection of the different phantom tests by edge detector, morphological operators, threshold histogram techniques, etc. The utility developed is enough sensitive to the radiographic equipment of operating conditions of voltage (kV) and charge (mAs). It is a friendly user programme connected with a data base of the hospital or clinic where it has been used. After the phantom image processing the user can obtain an inform with a resume of the imaging system state with accepting and constancy results. (author)

  17. Specific developed phantoms and software to assess radiological equipment image quality

    Energy Technology Data Exchange (ETDEWEB)

    Verdu, G., E-mail: gverdu@iqn.upv.es [Universidad Politecnica de Valencia (Spain). Dept. de Ingenieria Quimica y Nuclear; Mayo, P., E-mail: p.mayo@titaniast.com [TITANIA Servicios Teconologicos, Valencia (Spain); Rodenas, F., E-mail: frodenas@mat.upv.es [Universidad Politecnica de Valencia (Spain). Dept. de Matematica Aplicada; Campayo, J.M., E-mail: j.campayo@lainsa.com [Logistica y Acondicionamientos Industriales S.A.U (LAINSA), Valencia (Spain)

    2011-07-01

    The use of radiographic phantoms specifically designed to evaluate the operation of the radiographic equipment lets the study of the image quality obtained by this equipment in an objective way. In digital radiographic equipment, the analysis of the image quality can be automatized because the acquisition of the image is possible in different technologies that are, computerized radiography or phosphor plate and direct radiography or detector. In this work we have shown an application to assess automatically the constancy quality image in the image chain of the radiographic equipment. This application is integrated by designed radiographic phantoms which are adapted to conventional, dental equipment and specific developed software for the automatic evaluation of the phantom image quality. The software is based on digital image processing techniques that let the automatic detection of the different phantom tests by edge detector, morphological operators, threshold histogram techniques, etc. The utility developed is enough sensitive to the radiographic equipment of operating conditions of voltage (kV) and charge (mAs). It is a friendly user programme connected with a data base of the hospital or clinic where it has been used. After the phantom image processing the user can obtain an inform with a resume of the imaging system state with accepting and constancy results. (author)

  18. Interim staff position on environmental qualification of safety-related electrical equipment: including staff responses to public comments. Regulatory report

    International Nuclear Information System (INIS)

    Szukiewicz, A.J.

    1981-07-01

    This document provides the NRC staff positions regarding selected areas of environmental qualification of safety-related electrical equipment, in the resolution of Unresolved Safety Issue A-24, 'Qualification of Class IE Safety-Related Equipment.' The positions herein are applicable to plants that are or will be in the construction permit (CP) or operating license (OL) review process and that are required to satisfy the requirements set forth in either the 1971 or the 1974 version of IEEE-323 standard

  19. Design and manufacture of densitometer using in industrial radiography

    International Nuclear Information System (INIS)

    Nguyen Duc Huyen; Do Minh Duc; Vu Tien Ha; Dang Thanh Dung; Nguyen Do Kien

    2016-01-01

    Densitometer is a small device used to determine the darkness degree of radiography film. For improving the quality of the image on the film densitometer is indispensable equipment in sector related to the image, especially in the field of industrial imaging, radiographic. In Vietnam there are hundreds of densitometer devices, distributed to over 60 companies performing work on NDT sector and other companies. However, due to lack of maintenance, calibration and repair, many devices have been damaged, or unstable operation without any technical supports from the manufacturers. Up to now, Vietnam does not have any manufacturer (domestic and/or foreign) to research and development of the Densitometer. For these reasons, the scientists of Centre for Non-destructive Evaluation (NDE) with support from Vietnam Atomic Energy Institute (VINATOM) have successfully researched and manufactured the Densitometer using in industrial radiography in 2015.The equipment has been tested in practice and showed stable performance, measurement accuracy: ± 1% 0.02D; darkness range of film: 0.00 to 4.00D; repeated measurement values : ± 0.02D. The device meets ASTM 1079-00 standard for densitometer in industry. Especially, thanks to successful domestic manufacturing, the price of the device is only 60 % compared to the same imported products. (author)

  20. Radiation protection at industrial radiography in Germany exposures and unusual events

    International Nuclear Information System (INIS)

    Czarwinski, R.; Haeusler, U.; Frasch, G.

    2006-01-01

    In the Federal Republic of Germany safety related events in the use and transportation of radioactive materials as well as in the operation of accelerators are registered. The analysis of these events reveals their causation and allows this conclusions on avoidable errors. In this paper, a special insight is given into events in the field of gamma radiography which is a technical application of ionising radiation for non destructive testing of materials. Conclusions from analysis are drawn. In addition, the occupational radiation exposure of workers is presented taking into account that industrial radiography is performed under particular working conditions with different risks. (orig.)

  1. Dosimetric evaluation in panoramic and tele-radiography procedures; Avaliacao dosimetrica em procedimentos de radiografia panoramica e teleradiografias

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Georgge Gomes

    2004-07-01

    The present work had as an objective to evaluate the skin surface entrance dose in panoramic and tele radiography procedures in three clinics in Recife - Pernambuco - Brazil, and to contribute with data for the determination of reference levels for super cited extra oral procedures, for this purpose, operational conditions in 3 clinics were evaluated in Recife, aiming to evaluate the existence and integrity of the radioprotection equipment, manner and conditions of image processing; and radiographic equipment parameters such as the dimension of the irradiation filed, the total filtration, the exposure time and the potential applied to the X ray tube. For an estimation of the skin entrance dose of the patient, the phantom Randon Alderson and thermoluminescence dosemeters were used. From these values and the conversion factors determined by the Monte Carlo technique, with the phantom MAX it was possible to estimate the dose absorbed in the organ due to the tele radiography procedures. Regarding panoramic radiography the study showed that the more elevated doses occurred in the parotid gland region which is near rotational venters. In the case of tele radiography the highest dose value occurred in the regions corresponding to the temporal lobe of the brain, followed by linfonodes, ears and parotid glands. The doses absorbed in the eyes and the thyroid gland were, 0.037 mGy and 0.002 mGy in Clinic A and 0.062 mGy and 0.003 mGy in Clinic C, respectively. Regarding equipment test, inadequacy was found in the beam collimation in Clinic A and in the reproducibility of the X ray exposure in Clinic C. The total filtration in both clinics was inadequate.(author)

  2. Transport of Gamma Radiography Apparatus (Dangerous Goods 1978, no. 7)

    International Nuclear Information System (INIS)

    1978-01-01

    The Minister of Transport amended the Regulations on the Transport of Dangerous Goods of 15 April 1945 by Order dated 24 August 1978. The modifications concern the safety conditions to be complied with for the transport of portable industrial gamma radiography apparatus containing sealed radioactive sources. (NEA) [fr

  3. Digital radiography in NDT applications

    International Nuclear Information System (INIS)

    Deprins, E.

    2004-01-01

    A lot of film radiography could be replaced by today's technologies in the field of digital radiography. Only few of these applications have indeed replaced film. The choice to go digital depends on cost, quality requirement, workflow and throughput. Digital images offer a lot of advantages in terms of image manipulation and workflow. But despite the many advantages, a lot of considerations are needed before someone can decide to convert his organization from conventional to digital radiography. This paper gives an overview of all different modalities that can be used in digital radiography with today's technologies, together with the experiences of the pioneers of digital radiography. Film Scanning, Computed Radiography and Digital Radiography by using of different kinds of flat panel detectors all have their specific application fields and customers. What is the status of the technology today, which advantages brings digital radiography, and which are the limitations radiographers have to consider when replacing film by digital systems. (author)

  4. Dichotomy between theory and practice in chest radiography and its impact on students.

    Science.gov (United States)

    Botwe, Benard O; Arthur, Lawrence; Tenkorang, Michael K K; Anim-Sampong, Samuel

    2017-06-01

    It is important that theory is synchronous with clinical practices that students engage in. Lack of congruence between theory and practice presents serious problems to students. This study was therefore conducted to determine if there was a theory-practice gap in chest radiography during clinical rotations, and any associated causes and effects on radiography students. A descriptive survey design was used to conduct this study from 2 February to 27 July 2014. A semi-structured questionnaire consisting of open- and close-ended questions was used to purposively collect data from 26 radiography students in Ghana who had completed theory lessons in chest radiography and had either completed or were undertaking clinical rotations in chest radiography. Twenty-five (96%) respondents indicated the presence of theory-practice gap in chest radiography during clinical rotations, where differences between theory and clinical practice were observed. Lack of working materials 16 (62%), heavy workload 14 (54%), equipment breakdowns 14 (54%) and supervisory factors 11 (43%) were identified as the causes. Many students (81%) experienced diverse adverse effects such as confusion 10 (38%), poor performance during clinical examinations 6 (23%) and entire loss of interest in the professional training 1 (4%) of this dichotomy. Dichotomy between theory and practice found in chest radiography has diverse adverse effects on students. Regular feedback on the quality of clinical practice received by students should be encouraged to determine the existence of any gaps between theory and practice in order to promote effective clinical rotation programmes in radiography. © 2016 The Authors. Journal of Medical Radiation Sciences published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Medical Imaging and Radiation Therapy and New Zealand Institute of Medical Radiation Technology.

  5. International Neutron Radiography Newsletter

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    At the First World Conference on Neutron Radiography i t was decided to continue the "Neutron Radiography Newsletter", published previously by J.P. Barton, as the "International Neutron Radiography Newsletter" (INRNL), with J.C. Doraanus as editor. The British Journal of Non-Destructive Testing...

  6. Qualitative discussion of quantitative radiography

    International Nuclear Information System (INIS)

    Berger, H.; Motz, J.W.

    1975-01-01

    Since radiography yields an image that can be easily related to the tested object, it is superior to many nondestructive testing techniques in revealing the size, shape, and location of certain types of discontinuities. The discussion is limited to a description of the radiographic process, examination of some of the quantitative aspects of radiography, and an outline of some of the new ideas emerging in radiography. The advantages of monoenergetic x-ray radiography and neutron radiography are noted

  7. Radiographers' professional knowledge regarding parameters and safety issues in plain radiography: a questionnaire survey.

    Science.gov (United States)

    Farajollahi, A R; Fouladi, D F; Ghojazadeh, M; Movafaghi, A

    2014-08-01

    To review the knowledge of radiographers and examine the possible sociodemographic and situational contributors to this knowledge. A questionnaire survey was devised and distributed to a cohort of 120 radiographers. Each questionnaire contained two sections. In the first section, background data, including sex, age, highest academic level, grade point average (GPA), length of time from graduation, work experience as a radiographer and the status of previous refresher course(s), were collected. The second section contained 17 multiple-choice questions concerning radiographic imaging parameters and safety issues. The response rate was 63.8%. In univariate analytic model, higher academic degree (p workplace (p = 0.04) and taking previous refresher course(s) (p = 0.01) were significantly associated with higher knowledge score. In multivariate analytic model, however, higher academic degree (B = 1.62; p = 0.01), higher GPA (B = 0.50; p = 0.01) and taking previous refresher course(s) (B = -1.26; p = 0.03) were independently associated with higher level of knowledge. Age, sex, length of time from graduation and work experience were not associated with the respondents' knowledge score. Academic background is a robust indicator of a radiographer's professional knowledge. Refresher courses and regular knowledge assessments are highly recommended. This is the first study in the literature that examines professional knowledge of radiographers in terms of technical and safety issues in plain radiography. Academic degree, GPA and refresher courses are independent predictors of this knowledge. Regular radiographer professional knowledge checks may be recommended.

  8. Neutron radiography at the Institut de Maintenance Aeronautique

    International Nuclear Information System (INIS)

    Cluzeau, S.

    1999-01-01

    Recently the French Institut de Maintenance Aeronautique (IMA) decided to open a new field of research specially devoted to the inspection methods that should be used by the aircraft overhauling industry. Taking into account its proved ability for an early corrosion detection, neutron radiography (NR) was selected as an inspection method to be appraised. This paper presents the approach that IMA intends to follow for achieving this objective and involving selection of equipment, design of the facility and research program.(author)

  9. Radiation protection calculations for diagnostic medical equipment

    International Nuclear Information System (INIS)

    Klueter, R.

    1992-01-01

    The standards DIN 6812 and DIN 6844 define the radiation protection requirements to be met by biomedical radiography equipment or systems for nuclear medicine. The paper explains the use of a specific computer program for radiation protection calculations. The program offers menu-controlled calculation, with free choice of the relevant nuclides. (DG) [de

  10. The method for assurance to operational safety of cryogenics equipment through definite maintenance

    International Nuclear Information System (INIS)

    Anghel, Vasile

    2004-01-01

    The present paper reports about a method of ensuring operational safety of cryogenics equipment through specific maintenance measures which imply a definite concept of maintainability and operational reliability, methods of maintenance, necessary logistic and necessary personnel. The stages of the concept should succeed in a logical order and must be based on detailed analyses of the process of maintenance. The method starts from the operation conditions of cryogenic equipment in nuclear regime. Thus maintenance policy must be well defined within the boundaries of the nuclear plant through definition of coherent objectives and responsibility delegation for the personnel implied in maintenance activity. This method ensures performance in maintenance and an efficient feedback from equipment analysis. (author)

  11. Investigation of potential fire-related damage to safety-related equipment in nuclear power plants

    International Nuclear Information System (INIS)

    Wanless, J.

    1985-11-01

    Based on a review of vendor information, fire damage reports, equipment qualification and hydrogen burn test results, and material properties, thirty-three types of equipment found in nuclear power plants were ranked in terms of their potential sensitivity to fire environments. The ranking considered both the functional requirements and damage proneness of each component. A further review of the seven top-ranked components was performed, considering the relative prevalence and potential safety significance of each. From this, relays and hand switches dominate as first choices for fire damage testing with logic equipment, power supplies, transmitters, and motor control centers as future candidates

  12. Co-operation Equipment Qualification for Safety grade I and C Equipment between Russia and Korea

    International Nuclear Information System (INIS)

    Ham, J. K.; Lee, D. H.; Park, J. W.; Jeong, M. H.; Choi, Y. H.; Suh, J. J.; Jang, T. H.

    2007-06-01

    Equipment Qualification technology for I and C system on nuclear grade have been approved with accurate and safe for verifying and validation. It contributes to acknowledge of reliability and to review of user approval. Also it did not completely satisfied the requirement of Russia, it can be satisfied by bit of modification on design. It is expected to support the export of safety PLC to nuclear power plant. Proven EQ technology is required on the further markets of nuclear. Therefore, comparison test with foreign country is necessary to support the mutual accreditation of EQ for export of domestic products

  13. Co-operation Equipment Qualification for Safety grade I and C Equipment between Russia and Korea

    Energy Technology Data Exchange (ETDEWEB)

    Ham, J. K.; Lee, D. H.; Park, J. W.; Jeong, M. H.; Choi, Y. H.; Suh, J. J.; Jang, T. H. [Korea Testing Laboratory, Seoul (Korea, Republic of)

    2007-06-15

    Equipment Qualification technology for I and C system on nuclear grade have been approved with accurate and safe for verifying and validation. It contributes to acknowledge of reliability and to review of user approval. Also it did not completely satisfied the requirement of Russia, it can be satisfied by bit of modification on design. It is expected to support the export of safety PLC to nuclear power plant. Proven EQ technology is required on the further markets of nuclear. Therefore, comparison test with foreign country is necessary to support the mutual accreditation of EQ for export of domestic products.

  14. Radiography at CERN

    CERN Multimedia

    HSE Unit

    2014-01-01

    What is industrial radiography? It is a non-destructive method with a wide variety of applications, such as inspecting the quality of a weld. It uses high-energy radioactive sources or an X-ray generator.   Is this inspection technique used at CERN? Yes, it is widely used at CERN by the EN-MME Group, which outsources the work to one or more companies, depending on the workload. Is it possible to carry out radiography anywhere at CERN? Yes, it is possible to carry out radiography in any building/accelerator/experiment area at CERN (including in areas which are not normally subject to radiological hazards). When is radiography carried out? It normally takes place outside of working hours (7 p.m. to 6 a.m.). How will I know if radiography is taking place in my building? If this activity is planned in a CERN building, notices will be affixed to all of its main entrance doors at least 24 hours in advance. What are the risks? There is a risk of exposure to very high levels of radiation, dep...

  15. An overview of digital radiography

    International Nuclear Information System (INIS)

    Aweligiba, S. A.

    2013-04-01

    The medical application of radiography has gained wider study since diagnostic radiology plays a very important role in modern medicine for fast diagnosis and therapy. Digital radiography is a relatively new technology that promises greater accuracy, lesser dose and better manipulation of patient radiology images in hospitals. In this study, a general discussion on digital radiography has been presented. The presentation focuses on the optimisation of doses to patients in the medical application of digital radiography, quality control and quality assurance. A brief presentation on performance indicators in digital radiography has also been presented. The advantages of digital radiography over the conventional film/screen system have been elaborated and its limitations are also outlined. (author)

  16. Proton nuclear scattering radiography

    International Nuclear Information System (INIS)

    Duchazeaubeneix, J.C.; Faivre, J.C.; Garreta, D.

    1982-10-01

    Nuclear scattering of protons allows to radiograph objects with specific properties: direct 3- dimensional radiography, different information as compared to X-ray technique, hydrogen radiography. Furthermore, it is a well adapted method to gating techniques allowing the radiography of fast periodic moving systems. Results obtained on different objects (light and heavy materials) are shown and discussed. The dose delivery is compatible with clinical use, but at the moment, the irradiation time is too long between 1 and 4 hours. Perspectives to make the radiography faster and to get a practical method are discussed

  17. Simulation of the radiography formation process from CT patient volume

    International Nuclear Information System (INIS)

    Bifulco, P.; Cesarelli, M.; Verso, E.; Roccasalva Firenze, M.; Sansone, M.; Bracale, M.

    1998-01-01

    The aim of this work is to develop an algorithm to simulate the radiographic image formation process using volumetric anatomical data of the patient, obtained from 3D diagnostic CT images. Many applications, including radiographic driven surgery, virtual reality in medicine and radiologist teaching and training, may take advantage of such technique. The designed algorithm has been developed to simulate a generic radiographic equipment, whatever oriented respect to the patient. The simulated radiography is obtained considering a discrete number of X-ray paths departing from the focus, passing through the patient volume and reaching the radiographic plane. To evaluate a generic pixel of the simulated radiography, the cumulative absorption along the corresponding X-ray is computed. To estimate X-ray absorption in a generic point of the patient volume, 3D interpolation of CT data has been adopted. The proposed technique is quite similar to those employed in Ray Tracing. A computer designed test volume has been used to assess the reliability of the radiography simulation algorithm as a measuring tool. From the errors analysis emerges that the accuracy achieved by the radiographic simulation algorithm is largely confined within the sampling step of the CT volume. (authors)

  18. Efficacy of daily bedside chest radiography as visualized by digital luminescence radiography

    International Nuclear Information System (INIS)

    Kirchner, J.; Stueckle, C.A.; Schilling, E.M.; Peters, J.

    2001-01-01

    To determine the diagnostic impact of daily bedside chest radiography in comparison with digital luminescence technique (DLR; storage phosphor radiography) and conventional film screen radiography, a prospective randomized study was completed in 210 mechanically ventilated patients with a total of 420 analysed radiographs. The patients were allocated to two groups: 150 patients underwent DLR, and 60 patients underwent conventional film screen radiography. Radiological analysis was performed consensually and therapeutic efficacy was assessed by the clinicians. There was no statistical significant difference between the frequency of abnormal findings seen on DLR and conventional film screen radiography. In total, 448 abnormal findings were present in 249 of 300 DLR and 97 of 120 conventional film screen radiographs. The most common findings were signs of overhydration (41 %), pleural effusion (31%), partial collapse of the lung (11%) and pneumothorax (2%). One hundred and twenty-three of 448 (27%) of these abnormal findings were thought to have a considerable impact on patient management. The high rate of abnormal findings with significant impact on patient management suggests that the use of daily bedside chest radiography may be reasonable. Copyright (2001) Blackwell Science Pty Ltd

  19. Comparison of the quality of the chest film between digital radiography and conventional high kV radiography

    International Nuclear Information System (INIS)

    Zeng Qingsi; Cen Renli; Chen Ling; He Jianxun; Lin Hanfei

    2003-01-01

    Objective: To evaluate the quality and usefulness of direct digital radiography system in roentgenogram of chest in clinical practice. Methods: 1000 cases of chest roentgenograms with digital radiography and high kV conventional radiography were selected for analysis by 3 senior radiologists. Results: 1. With digital radiography system, the quality of chest film was assessed as grade A in 50.6%, grade B in 38.5%, grade C in 10.9%, and no waste film. 2. With conventional high kV radiography, the quality of chest film was assessed as grade A in 41.1%, grade B in 44.1%, grade C in 13.3%, and waste film in 1.5%. The direct digital radiography was statistically superior to the conventional high kV radiography. 3. The fine structure of the lungs could be revealed in 100.0% of chest roentgenogram with direct digital radiograph system, which was significantly higher than that acquired with the conventional high KV radiography (78.6%, P < 0.001). Conclusion: Direct digital radiography could provide the chest film with better quality than that with the conventional high kV radiography. The direct digital radiography system is easy to operate, fast in capturing imaging and could provide post-processing techniques, which will facilitate the accurate diagnosis of chest radiography

  20. Daily quality control in computed radiography mammography using the manufacturer phantom

    International Nuclear Information System (INIS)

    Jakubiak, Rosangela R.; Messias, Pricila C.; Oliveira, Carlla M.

    2011-01-01

    The quality control (QC) in mammography system involves a large amount of test tools, which implies a large space for storage and a high number of exposure. This work describes a QC system using a phantom, Fuji Computed Radiography (FCR) One Shot Phantom M Plus, that evaluates several parameters with just one exposure. The software offers tests with annual, semi-annual, quarterly, weekly and daily periodicity, and analyzes the conformities of the mammography equipment, image plate and cassettes. Because of the high number of tests, it was evaluated the daily test only for seven months in two mammography equipment. The test, through the software and its image, allows the analysis of ten parameters in QC. The evaluation of these parameters was realized by the average of the values provided by the software. Only one of the evaluated items showed not conformity, but this was observed and the necessary corrections were realized. The monitoring of use of FCR Mammography QC software with the FCR One Shot Phantom M Plus was realized and through this we could investigate that the quality program provided by the system is appropriate for the radiology services that has the Fuji Computed Radiography system. (author)

  1. Measurement of Liquid-Metal Two-Phase Flow with a Dynamic Neutron Radiography

    International Nuclear Information System (INIS)

    Cha, J. E.; Lim, I. C.; Kim, H. R.; Kim, C. M.; Nam, H. Y.; Saito, Y.

    2005-01-01

    The dynamic neutron radiography(DNR) has complementary characteristics to X-ray radiography and is suitable to visualization and measurement of a multi-phase flow research in a metallic duct and liquid metal flow. The flow-field information of liquid metal system is very important for the safety analysis of fast breeder reactor and the design of the spallation target of accelerator driven system. A DNR technique was applied to visualize the flow field in the gas-liquid metal two-phase flow with the HANARO-beam facility. The lead bismuth eutectic and the nitrogen gas were used to construct the two-phase flow field in the natural circulation U-channel. The two-phase flow images in the riser were taken at various combinations of the liquid flow and gas flow with high frame-rate neutron radiography at 1000 fps

  2. A Study on Performance and Safety Tests of Electrosurgical Equipment

    Directory of Open Access Journals (Sweden)

    Tavakoli Golpaygani A.

    2016-09-01

    Full Text Available Introduction: Modern medicine employs a wide variety of instruments with different physiological effects and measurements. Periodic verifications are routinely used in legal metrology for industrial measuring instruments. The correct operation of electrosurgical generators is essential to ensure patient’s safety and management of the risks associated with the use of high and low frequency electrical currents on human body. Material and Methods: The metrological reliability of 20 electrosurgical equipment in six hospitals (3 private and 3 public was evaluated in one of the provinces of Iran according to international and national standards. Results: The achieved results show that HF leakage current of ground-referenced generators are more than isolated generators and the power analysis of only eight units delivered acceptable output values and the precision in the output power measurements was low. Conclusion: Results indicate a need for new and severe regulations on periodic performance verifications and medical equipment quality control program especially in high risk instruments. It is also necessary to provide training courses for operating staff in the field of meterology in medicine to be acquianted with critical parameters to get accuracy results with operation room equipment.

  3. Proton nuclear scattering radiography

    International Nuclear Information System (INIS)

    Saudinos, J.

    1982-04-01

    Nuclear scattering of protons allows to radiograph objects with specific properties: 3-dimensional radiography, different information as compared to X-ray technique, hydrogen radiography. Furthermore the nuclear scattering radiography (NSR) is a well adapted method to gating techniques allowing the radiography of fast periodic moving objects. Results obtained on phantoms, formalin fixed head and moving object are shown and discussed. The dose delivery is compatible with clinical use, but at the moment, the irradiation time is too long between 1 and 4 hours. Perspectives to make the radiograph faster and to get a practical method are discussed

  4. The stationary neutron radiography system

    International Nuclear Information System (INIS)

    Weeks, A.A.; Newell, D.L.; Heidel, C.C.

    1990-01-01

    To provide the high intensity neutron beam and support systems necessary for radiography, the Stationary Neutron Radiography System was constructed at McClellan Air Force Base. The Stationary Neutron Radiography System utilizes a one megawatt TRIGA reactor contained in an Aluminium tank surrounded by eight foot thick concrete walls. There are four neutron beam tubes at inclined angles from the reactor core to separate radiography bays. In three of the bays, robotic systems manipulate aircraft components in the neutron beam, while real-time imaging systems provide images concurrent with the irradiation. Film radiography of smaller components is performed in the remaining bay

  5. Occupational exposure in Greek industrial radiography laboratories (2004-2006) and comparison of doses with other industrial applications

    International Nuclear Information System (INIS)

    Tritakis, P.; Papadomarkaki, E.; Economides, S.; Carinou, E.; Hourdakis, C.; Kamenopoulou, V.; Dimitriou, P.

    2008-01-01

    Full text: In this study the Mean Annual Dose (MAD) of all industrial radiography workers in Greece for the time period 2004-2006 is evaluated and correlated to the practice and type of equipment used. All data used in this study come from the National Dose Registry Information System of the Greek Atomic Energy Commission. The present study constitutes the follow up of two previous studies, where a Dose Constraint (DC) for industrial radiography in Greece, equal to 4.0mSv was introduced for the first time. The introduction and systematic use of a dynamic DC value aims to optimize common working practices through a continuous decrease of occupational doses. In the current work a further decrease in the industrial radiography personnel doses is observed and the factors leading to this result are analyzed. Finally, the estimated MAD value for exposed workers in industrial radiography is compared to the ones corresponding to workers in other industrial applications involving the use of ionizing radiation

  6. Chest X-Ray (Chest Radiography)

    Science.gov (United States)

    ... Resources Professions Site Index A-Z X-ray (Radiography) - Chest Chest x-ray uses a very small dose ... Radiography? What is a Chest X-ray (Chest Radiography)? The chest x-ray is the most commonly performed diagnostic ...

  7. Traps in quality assurance of diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Meier, N.; Lenzen, H.; Fiebich, M.

    1992-01-01

    With the introduction of the German industrial protocol for quality assurance of X-ray equipment, everybody using X-ray machines fell into sort of trap or found some of the procedures misleading. Vigorous discussions were held on every conceivable aspect of this and other protocols, and are still in progress. This paper points out some of the common traps and considers a new type dosimeter, which allows a definite separation of quality assurance of X-ray equipment and of processing and which can also be used in future for quality assurance of digital radiography equipment. (orig.) [de

  8. Evaluation of radiation protection parameters in dental radiography in the State of Rio de Janeiro, Brazil

    International Nuclear Information System (INIS)

    Dovales, Ana Cristina M.; Oliveira, Sergio L. Girao de; Cucco, Antonio Carlos S.; Bezerra, Marcos Antonio; Mota, Helvecio C.

    2001-01-01

    This paper presents the results obtained in a program for the postal evaluation of radiation protection parameters in dental radiography in the state of Rio de Janeiro. The postal kit contains a radiographic film and two pairs of thermoluminescent dosimeters separated by a 3 mm aluminium filter and is accompanied by a questionnaire about equipment characteristics and exposition parameters. The analysis of 2596 equipment in the last three years showed that near half of the examinations produces doses higher than the diagnostic reference level established by the health authorities for this kind of examination. Field diameter is within the acceptable range in 73,5% of the tests and total filtration is higher than 1,5 mm Al equivalent in 86,64% of the cases. Comparing with earlier results this analysis suggests that radiation protection conditions in dental radiography are improving in the state of Rio de Janeiro. (author)

  9. JRR-3 neutron radiography facility

    International Nuclear Information System (INIS)

    Matsubayashi, M.; Tsuruno, A.

    1992-01-01

    JRR-3 neutron radiography facility consists of thermal neutron radiography facility (TNRF) and cold neutron radiography facility (CNRF). TNRF is installed in JRR-3 reactor building. CNRF is installed in the experimental beam hall adjacent to the reactor building. (author)

  10. On safety 1E qualification of electrical equipment for nuclear power stations

    International Nuclear Information System (INIS)

    Segarceanu, D.; Geambasu, C.; Avramescu, M.

    1995-01-01

    Electrical equipment and systems for the emergency shutdown of a nuclear reactor are qualified according to safety class 1E. Methods of qualification meeting the requirements should be used, either individually or in combination include, type-test qualification, qualification by operating experience, qualification by analysis, combined qualification. These methods qualification principles, procedures and documents are discussed. (N.T.). 1 fig

  11. 6 MeV RF Linac for cargo scanning and industrial radiography

    International Nuclear Information System (INIS)

    2017-01-01

    RF Linac-based X-ray sources are very widely used for cargo-scanning and industrial X-ray radiography applications. A 6 MeV on-axis coupled-cavity S-band RF linac has been designed, developed and tested successfully at Electron Beam Centre, Navi Mumbai. This facility falls under the purview of BARC Safety Council, which has conducted safety reviews and awarded regulatory clearances for the operation of the linac system. This paper outlines the salient features of the 6 MeV linac, its safety aspects and test results. A brief history of regulatory aspects is also presented

  12. High-speed radiography and x-ray cinematography by high-current betatrons

    International Nuclear Information System (INIS)

    Akimochkin, Yu.V.; Akulov, G.V.; Leunov, F.G.; Moskalev, V.A.; Ryabukhin, V.L.

    1979-01-01

    The paper provides a description of an equipment system comprising a pair of 25 MeV high-current betatrons and an X-ray drum-type cinecamera for high-speed radiography and X-ray cinematography for use when studying dynamics of objects moving at a rate of 0.5 - 3.0 km/s as well as in X-ray cinematography of processes at a rate of up to 1 m/s. (author)

  13. Neutron radiography at the HFR Petten

    International Nuclear Information System (INIS)

    Markgraf, J.F.W.

    1990-03-01

    This report contains the five papers on neutron radiography activities at the Petten High Flux Reactor (HFR) presented at the Third World Conference on Neutron Radiography which was held in May 1989 in Osaka, Japan. In addition, a survey on neutron radiography in Europe for industry and research as presented at the SITEF NDT symposium 1989 on European Advances in Non-Destructive Testing, held in Toulouse/France in October 1989 is included. The papers compiled here are concerned with: the neutron radiography services available in Petten; the experience with and applications of neutron radiography at Petten; image evaluation and analysis techniques at Petten; the practical utilization of nitrocellulose film in neutron radiography in Europe; an introduction into the basic principles of neutron radiography; an overview of the neutron radiography facilities in Europe for industry and research; and a survey of typical applications of neutron radiography in industry, research and sciences. It is the intention of this compilation to provide a comprehensive overview of the present Petten activities and European facilities in this young and promising field of non-destructive testing of materials and components from the nuclear and the non-nuclear industries and research organizations, and from the sciences

  14. Evaluation of occupational exposure in intraoral radiography

    International Nuclear Information System (INIS)

    Miguel, Cristiano; Barros, Frieda S.; Rocha, Anna S.P.S.; Godoi, Walmor C.; Tilly Junior, Joao G.

    2014-01-01

    The intraoral radiography is widely performed in the dental office due to low cost and agility. The doses in intraoral radiology are considered low, however it is known that doses below the threshold for deterministic radiation has the potential to induce stochastic effects. An intraoral radiography has a risk of inducing fatal cancer or serious in order of 1:10,000,000. Besides the patient, the dentist may also be being exposed to radiation during the work with the radiographics practices. The bibliographies demonstrates the lack of information on radiation protection of dentists, however, the occupational dose reduction was observed in radiology over the past 14 years. This work aims to evaluate the effective dose of radiation to which workers can be exposed dentists in dental offices to perform intraoral radiographs. In this context, a study was be conducted between June 2013 and May 2014 with 44 professionals in Curitiba city. For each dentist was given a personal dosimeter to be used for 30 days. During this period, the number of radiographies and the length of the cable triggers of the X-ray equipment was registered and, the dosimeter´s dose was read. It was observed that the cables triggers meet regulatory standards and allow dentists to get the mean minimum distance of two meters from the radiation source in 93% of cases. Through analysis of the doses, it was concluded that occupational exposures of these workers are within the recommended threshold by regulatory 453/1998 of the Ministry of Health from Brazil. (author)

  15. Student Incivility in Radiography Education.

    Science.gov (United States)

    Clark, Kevin R

    2017-07-01

    To examine student incivility in radiography classrooms by exploring the prevalence of uncivil behaviors along with the classroom management strategies educators use to manage and prevent classroom disruptions. A survey was designed to collect data on the severity and frequency of uncivil student behaviors, classroom management strategies used to address minor and major behavioral issues, and techniques to prevent student incivility. The participants were educators in radiography programs accredited by the Joint Review Committee on Education in Radiologic Technology. Findings indicated that severe uncivil student behaviors in radiography classrooms do not occur as often as behaviors classified as less severe. Radiography educators in this study used a variety of strategies and techniques to manage and prevent student incivility; however, radiography educators who received formal training in classroom management reported fewer incidents of student incivility than those who had not received formal training. The participants in this study took a proactive approach to addressing severe behavioral issues in the classroom. Many radiography educators transition from the clinical environment to the classroom setting with little to no formal training in classroom management. Radiography educators are encouraged to attend formal training sessions to learn how to manage the higher education classroom effectively. Student incivility is present in radiography classrooms. This study provides a foundation for future research on incivility. ©2017 American Society of Radiologic Technologists.

  16. Analysis of Medical Equipment Management in Relation to the Mandatory Medical Equipment Safety Manager (MESM in Japan

    Directory of Open Access Journals (Sweden)

    Kai Ishida

    2014-01-01

    Full Text Available Half a decade has passed since the fifth revision of the medical law and mandatory appointment of a medical equipment safety manager (MESM in hospitals in Japan. During this period, circumstances have changed regarding maintenance of medical equipment (ME. We conducted a survey to examine these changes and the current situation in ME management. Maintenance of ME and related work were found to have increased in many hospitals, but the number of clinical engineering technologists (CETs has only slightly increased. The appointed MESM was a CET or physician in most hospitals. In hospitals where physicians were appointed as the MESM, 81% had operation managers. Many respondents commented that it was difficult for one person to cover all the tasks required by the MESM, due to a lack of knowledge, too much work, or other reasons. This suggests the importance of an operation manager for ME to work under the MESM.

  17. Dose measurements in intraoral radiography using thermoluminescent dosimeters

    Science.gov (United States)

    Azorín, C.; Azorín, J.; Aguirre, F.; Rivera, T.

    2015-01-01

    The use of X-ray in medicine demands to expose the patient and the professional to the lowest radiation doses available in agreement with ALARA philosophy. The reference level for intraoral dental radiography is 7 mGy and, in Mexico, a number of examinations of this type are performed annually. It is considered that approximately 25% of all the X-rays examinations carried out in our country correspond to intraoral radiographies. In other hand, most of the intraoral X-ray equipment correspond to conventional radiological systems using film, which are developed as much manual as automatically. In this work the results of determining the doses received by the patients in intraoral radiological examinations made with different radiological systems using LiF:Mg,Cu,P+PTFE thermoluminescent dosimeters are presented. In some conventional radiological systems using film, when films are developed manual or automatically, incident kerma up to 10.61 ± 0.74 mGv were determined. These values exceed that reference level suggested by the IAEA and in the Mexican standards for intraoral examinations.

  18. Dose measurements in intraoral radiography using thermoluminescent dosimeters

    International Nuclear Information System (INIS)

    Azorín, C; Rivera, T; Azorín, J; Aguirre, F

    2015-01-01

    The use of X-ray in medicine demands to expose the patient and the professional to the lowest radiation doses available in agreement with ALARA philosophy. The reference level for intraoral dental radiography is 7 mGy and, in Mexico, a number of examinations of this type are performed annually. It is considered that approximately 25% of all the X-rays examinations carried out in our country correspond to intraoral radiographies. In other hand, most of the intraoral X-ray equipment correspond to conventional radiological systems using film, which are developed as much manual as automatically. In this work the results of determining the doses received by the patients in intraoral radiological examinations made with different radiological systems using LiF:Mg,Cu,P+PTFE thermoluminescent dosimeters are presented. In some conventional radiological systems using film, when films are developed manual or automatically, incident kerma up to 10.61 ± 0.74 mGv were determined. These values exceed that reference level suggested by the IAEA and in the Mexican standards for intraoral examinations

  19. Fresh-Core Reload of the Neutron Radiography (NRAD) Reactor with Uranium(20)-Erbium-Zirconium-Hydride Fuel

    Energy Technology Data Exchange (ETDEWEB)

    John D. Bess; Thomas L. Maddock; Margaret A. Marshall; Leland M. Montierth

    2013-03-01

    The neutron radiography (NRAD) reactor is a 250 kW TRIGA® (Training, Research, Isotopes, General Atomics) Mark II , tank-type research reactor currently located in the basement, below the main hot cell, of the Hot Fuel Examination Facility (HFEF) at the Idaho National Laboratory (INL). It is equipped with two beam tubes with separate radiography stations for the performance of neutron radiography irradiation on small test components. The initial critical configuration developed during the fuel loading process, which contains only 56 fuel elements, has been evaluated as an acceptable benchmark experiment. The 60-fuel-element operational core configuration of the NRAD LEU TRIGA reactor has also been evaluated as an acceptable benchmark experiment. Calculated eigenvalues differ significantly (~±1%) from the benchmark eigenvalue and have demonstrated sensitivity to the thermal scattering treatment of hydrogen in the U-Er-Zr-H fuel.

  20. Neutron radiography

    International Nuclear Information System (INIS)

    Alaa eldin, M.T.

    2011-01-01

    The digital processing of the neutron radiography images gives the possibility for data quantification. In this case an exact relation between the measured neutron attenuation and the real macroscopic attenuation coefficient for every point of the sample is required. The assumption that the attenuation of the neutron beam through the sample is exponential is valid only in an ideal case where a monochromatic beam, non scattering sample and non background contribution are assumed. In the real case these conditions are not fulfilled and in dependence on the sample material we have more or less deviation from the exponential attenuation law. Because of the high scattering cross-sections of hydrogen (σs=80.26 barn) for thermal neutrons, the problem with the scattered neutrons at quantitative radiography investigations of hydrogenous materials (as PE, Oil, H 2 O, etc) is not trivial. For these strong scattering materials the neutron beam attenuation is no longer exponential and a dependence of the macroscopic attenuation coefficient on the material thickness and on the distance between the sample and the detector appears. When quantitative radiography (2 D) or tomography investigations (3 D) are performed, some image correction procedures for a description of the scattering effect are required. This thesis presents a method that can be used to enhance the neutron radiography image for objects with high scattering materials like hydrogen, carbon and other light materials. This method uses the Monte Carlo code, MCNP5, to simulate the neutron radiography process and get the flux distribution for each pixel of the image and determine the scattered neutrons distribution that causes the image blur and then subtract it from the initial image to improve its quality.

  1. Simulation of the radiography formation process from CT patient volume

    Energy Technology Data Exchange (ETDEWEB)

    Bifulco, P; Cesarelli, M; Verso, E; Roccasalva Firenze, M; Sansone, M; Bracale, M [University of Naples, Federico II, Electronic Engineering Department, Bioengineering Unit, Via Claudio, 21 - 80125 Naples (Italy)

    1999-12-31

    The aim of this work is to develop an algorithm to simulate the radiographic image formation process using volumetric anatomical data of the patient, obtained from 3D diagnostic CT images. Many applications, including radiographic driven surgery, virtual reality in medicine and radiologist teaching and training, may take advantage of such technique. The designed algorithm has been developed to simulate a generic radiographic equipment, whatever oriented respect to the patient. The simulated radiography is obtained considering a discrete number of X-ray paths departing from the focus, passing through the patient volume and reaching the radiographic plane. To evaluate a generic pixel of the simulated radiography, the cumulative absorption along the corresponding X-ray is computed. To estimate X-ray absorption in a generic point of the patient volume, 3D interpolation of CT data has been adopted. The proposed technique is quite similar to those employed in Ray Tracing. A computer designed test volume has been used to assess the reliability of the radiography simulation algorithm as a measuring tool. From the errors analysis emerges that the accuracy achieved by the radiographic simulation algorithm is largely confined within the sampling step of the CT volume. (authors) 16 refs., 12 figs., 1 tabs.

  2. Clinical Applications of Reverse Panoramic Radiography

    Directory of Open Access Journals (Sweden)

    Sujatha S Reddy

    2011-09-01

    Full Text Available The essence of oral and maxil-lofacial radiology is not only to be an important tool in the diagnostic assessment of dental patients but also to equip the clinician with the ability to interpret images of certain maxillocraniofacial structures of importance to dental, medical and surgical practices. Although combinations of several conven-tional x-ray projections can be adequate in a number of clinical situations, radiographic assessment of certain craniofacial structures some-times needs to be facilitated by other imaging modalities. A not-so-recent development called reverse panoramic radiography may be a useful adjuvant to such a situation, at least in the near future. It is essentially a technique where the patient is placed backwards in the panoramic machine in a reverse position in such a way that x-ray beam is directed through the patient’s face and the exit beam then passes through the patient’s head on the opposite side where it is captured on the receptor. The following manuscript is an attempt to throw light on this technique and the impact it may have on dental, medical and surgical practices. The advantages and disadvantages of reverse panoramic radiography and it’s comparison to conventional panoramic radiographs and other skull views are also dis-cussed.

  3. Digital chest radiography

    DEFF Research Database (Denmark)

    Debess, Jeanne Elisabeth; Johnsen, Karen Kirstine; Thomsen, Henrik

    on collimation and dose reduction in digital chest radiography Methods and Materials A retrospective study of digital chest radiography is performed to evaluate the primary x-ray tube collimation of the PA and lateral radiographs. Data from one hundred fifty self-reliant female patients between 15 and 55 years...

  4. Seismic qualification of equipment in operating nuclear power plants: Unresolved Safety Issue A-46

    International Nuclear Information System (INIS)

    Chang, T.Y.

    1987-02-01

    The margin of safety provided in existing nuclear power plant equipment to resist seismically induced loads and perform their intended safety functions may vary considerably, because of significant changes in design criteria and methods for the seismic qualification of equipment over the years. Therefore, the seismic qualification of equipment in operating plants must be reassessed to determine whether requalification is necessary. The objective of technical studies performed under the Task Action Plan A-46 was to establish an explicit set of guidelines and acceptance criteria to judge the adequacy of equipment under seismic loading at all operating plants, in lieu of requiring qualification to the current criteria that are applied to new plants. This report summarizes the work accomplished on USI A-46. In addition, the collection and review of seismic experience data and existing seismic test data are presented. Staff assessment of work accomplished under USI A-46 leads to the conclusion that the use of seismic experience data provides the most reasonable alternative to current qualification criteria. Consideration of seismic qualification by use of experience data was a specific task in USI A-46. Several other A-46 tasks serve to support the use of an experienced data base. The principal technical finding of USI A-46 is that seismic experience data, supplemented by existing seismic test data, applied in accordance with the guidelines developed, can be used to verify the seismic adequacy of mechanical and electrical equipment in operating nuclear plants. Explicit seismic qualification should be required only if seismic experience data or existing test data on similar components cannot be shown to apply

  5. Digital radiography of the chest: state of the art

    International Nuclear Information System (INIS)

    Souto, M.; Malagari, K.S.; Tucker, D.; Tahoces, P.G.; Correa, J.; Benakis, V.S.; Roussos, C.; Strigaris, K.A.; Vidal, J.J.; Barnes, G.T.; Fraser, R.G.

    1994-01-01

    Digital image acquisition possesses a number of advantages over conventional systems in radiographic examination of the chest, the most important of which is its greater dynamic range. In addition, once digital images are acquired, they can be processed by computer in ways that cannot be rivalled by conventional analog techniques. Finally, digital images can be stored, retrieved and transmitted to local or remote sites. Here the status of the different digital systems employed in chest radiology and commonly used image processing techniques are reviewed. Also discussed are the current clinical applications of integrating digital chest radiography with a picture archiving and communication system (PACS) along with the difficulties typically encountered. Studies with a variety of digital techniques have been carried out on several fronts. Computed radiography based on photostimulable phosphor (CR) has replaced screen-film imaging in certain applications (i.e. bedside imaging). However, CR has limitations, namely its poor X-ray utilisation efficiency at high X-ray tube voltages and sensitivity to scatter; therefore, it is not ideal for all applications. Recently, a dedicated digital chest unit with excellent X-ray utilisation efficiency at high X-ray tube potentials has been introduced. On the basis of the state-of-the-art capabilities and research during the past decade, recommendations are made regarding the most desirable equipment specifications for dedicated and bedside digital chest radiography. (orig.)

  6. Neutron radiography

    International Nuclear Information System (INIS)

    Bayon, G.

    1989-01-01

    Neutronography or neutron radiography, a non-destructive test method which is similar in its principle to conventional X-ray photography, presently occupies a marginal position among non-destructive test methods (NDT) (no source of suitable performance or cost). Neutron radiography associated with the ORPHEE reactor permits industrial testing; it can very quickly meet a cost requirement comparable to that of conventional test methods. In 1988, 2500 parts were tested on this unit [fr

  7. Test tools of physics radiography children as a support for safety radiation and safety patients

    International Nuclear Information System (INIS)

    Siti Masrochah; Yeti Kartikasari; Ardi Soesilo Wibowo

    2013-01-01

    Radiographic examination of the thorax children aged 1-3 years have a high sufficiently failure. This failure is caused by the movement and difficulty positioning the patient, resulting in the risk of repeat radiographs to patient safety particularly unnecessary radiation risks. It is therefore necessary to develop research on children design fixation devices. This research aims to create a design tool fixation on radiographs children to support radiation safety and patient safety. This research is a descriptive exploratory approach to tool design. The independent variables were the design tools, variable tool function test results, and radiographic variables controlled thorax. The procedure is done by designing data collection tools, further trials with 20 samples. Processing and analysis of data is done by calculating the performance assessment tool scores with range 1-3. The results showed that the design tool of fixation in the form of standard radiographic cassette equipped with chairs and some form of seat belt fixation. The procedure uses a tool fixation is routine radiographic follow thorax child in an upright position. Function test results aids fixation is to have an average score of 2.66, which means good. While the test results for each component, the majority of respondents stated that the reliability of the device is quite good with a score of 2.45 (60 %), convenience tool with a score of 2.60 (70 %), quality of the radiographs did not incontinence of the thorax radiograph with a score 2.55 (85 %), the child protection (security) with a score of 2.70 (70 %), good design aesthetic design with a score of 2.80 (80 %), addition of radiation from the others on the use of these tools do not need with a score of 2.80 (80 %), and there is no additional radiation due to repetitions with a score of 2.85 (90 %). (author)

  8. RADIOGRAPHY IN THE FIELD: ASSESSING A LIGHTWEIGHT, HANDHELD, BATTERY-POWERED DENTISTRY UNIT FOR FIELD DIAGNOSTIC APPLICATIONS.

    Science.gov (United States)

    Seilern-Moy, Katharina; Vielgrader, Hanna; Gerritsmann, Hanno; Walzer, Chris

    2017-03-01

    Radiography units are not used commonly in wildlife medicine field settings, primarily because of their weight and requirement for a power supply. In this study, a portable, battery-powered, and lightweight radiography unit, originally developed for dentistry, was assessed for its potential field applications. Radiographs of various animal species (ranging in weight from 14 g to 1,000 kg) were imaged using varying source image distance (SID) and exposure time. The quality of these images was evaluated for their resolution, image noise, and motion blur. When required, image resolutions were further enhanced using computed radiography postprocessing. Other parameters evaluated were the freehand use of the device, its battery durability, the maximum obtainable image size, and multiple use of a single computed radiography cassette. Using an SID of 60 cm, radiographs delivered adequate image quality. The quality, however, was found deteriorated in images of larger animals (>50 kg) or thicker tissues (>15 cm). The use of a tripod proved unnecessary in most cases, and its exclusion greatly facilitated equipment handling. Under field conditions, the battery was depleted after a total running time of 1.6 hr or 36 radiographs. The maximum size of a radiographic image reached a diameter of 40 cm, and radiation shielding allowed the multiple use of a single computed radiography cassette. Taken together, the radiography unit evaluated in this study presented a balanced compromise between portability and radiograph quality for field use. However, the unit image resolution cannot replace those of the fixed standard radiography units commonly used in veterinary medicine.

  9. A special ionisation chamber for quality control of diagnostic and mammography X ray equipment

    International Nuclear Information System (INIS)

    Costa, A.M.; Caldas, L.V.E.

    2003-01-01

    A quality control program for X ray equipment used for conventional radiography and mammography requires the constancy check of the beam qualities in terms of the half-value layers. In this work, a special double-faced parallel-plate ionisation chamber was developed with inner electrodes of different materials, in a tandem system. Its application will be in quality control programs of diagnostic and mammography X ray equipment for confirmation of half-value layers previously determined by the conventional method. Moreover, the chamber also may be utilised for measurements of air kerma values (and air kerma rates) in X radiation fields used for conventional radiography and mammography. The chamber was studied in relation to the characteristics of saturation, ion collection efficiency, polarity effects, leakage current, and short-term stability. The energy dependence in response of each of the two faces of the chamber was determined over the conventional radiography and mammography X ray ranges (unattenuated beams). The different energy responses of the two faces of the chamber allowed the formation of a tandem system useful for the constancy check of beam qualities. (author)

  10. A special ionisation chamber for quality control of diagnostic and mammography X ray equipment.

    Science.gov (United States)

    Costa, A M; Caldas, L V E

    2003-01-01

    A quality control program for X ray equipment used for conventional radiography and mammography requires the constancy check of the beam qualities in terms of the half-value layers. In this work, a special double-faced parallel-plate ionisation chamber was developed with inner electrodes of different materials, in a tandem system. Its application will be in quality control programs of diagnostic and mammography X ray equipment for confirmation of half-value layers previously determined by the conventional method. Moreover, the chamber also may be utilised for measurements of air kerma values (and air kerma rates) in X radiation fields used for conventional radiography and mammography. The chamber was studied in relation to the characteristics of saturation, ion collection efficiency, polarity effects, leakage current, and short-term stability. The energy dependence in response of each of the two faces of the chamber was determined over the conventional radiography and mammography X ray ranges (unattenuated beams). The different energy response of the two faces of the chamber allowed the formation of a tandem system useful for the constancy check of beam qualities.

  11. Industrial high pressure applications. Processes, equipment and safety

    Energy Technology Data Exchange (ETDEWEB)

    Eggers, Rudolf (ed.) [Technische Univ. Hamburg-Harburg, Hamburg (Germany). Inst. fuer Thermische Verfahrenstechnik

    2012-07-01

    Industrial high pressure processes open the door to many reactions that are not possible under 'normal' conditions. These are to be found in such different areas as polymerization, catalytic reactions, separations, oil and gas recovery, food processing, biocatalysis and more. The most famous high pressure process is the so-called Haber-Bosch process used for fertilizers and which was awarded a Nobel prize. Following an introduction on historical development, the current state, and future trends, this timely and comprehensive publication goes on to describe different industrial processes, including methanol and other catalytic syntheses, polymerization and renewable energy processes, before covering safety and equipment issues. With its excellent choice of industrial contributions, this handbook offers high quality information not found elsewhere, making it invaluable reading for a broad and interdisciplinary audience.

  12. New development in the certification of a component radiation protection officer in industrial radiography

    International Nuclear Information System (INIS)

    Ismail Bahari; Azwar, M.H.; Mohd Pauzi, M.S.

    2001-01-01

    The appointment of a Radiation protection Officer (RPO) by companies for activities related to the use of Atomic Energy, including Industrial Radiography is mandated under regulation 23 of the Radiation Protection (Basic Safety Standards) Regulations 1988. The regulations categorically requires the appointment of a competent person to help ensure radiation safety at work. Definition of competency has been spelt out in the regulations and this is translated to include having been trained and tested through examination by the AELB and be able to carry out the duties and responsibilities prescribed by the Act and Regulations. This paper discusses the development in the certification of RPO in the field of industrial radiography and what the new RPO certification scheme together with the Certification of RPO standard (LEMI/TEK/44) will do to increase competency as well as the market value of future RPOs. (Author)

  13. 78 FR 16358 - Safety Advisory 2013-02; Low-Speed, Wheel-Climb Derailments of Passenger Equipment With “Stiff...

    Science.gov (United States)

    2013-03-14

    ..., Staff Director, Motive Power and Equipment Division, Office of Railroad Safety, FRA, 1200 New Jersey Avenue SE., Washington, DC 20590, telephone (202) 493-6322; or Anna Nassif Winkle, Trial Attorney, Office... studies conducted by the equipment manufacturer and FRA using computer modeling indicate that an uneven...

  14. Megavoltage cargo radiography with dual energy material decomposition

    Science.gov (United States)

    Shikhaliev, Polad M.

    2018-02-01

    Megavoltage (MV) radiography has important applications in imaging large cargos for detecting illicit materials. A useful feature of MV radiography is the possibility of decomposing and quantifying materials with different atomic numbers. This can be achieved by imaging cargo at two different X-ray energies, or dual energy (DE) radiography. The performance of both single energy and DE radiography depends on beam energy, beam filtration, radiation dose, object size, and object content. The purpose of this work was to perform comprehensive qualitative and quantitative investigations of the image quality in MV radiography depending on the above parameters. A digital phantom was designed including Fe background with thicknesses of 2cm, 6cm, and 18cm, and materials samples of Polyethylene, Fe, Pb, and U. The single energy images were generated at x-ray beam energies 3.5MV, 6MV, and 9MV. The DE material decomposed images were generated using interlaced low and high energy beams 3.5/6MV and 6/9MV. The X-ray beams were filtered by low-Z (Polyethylene) and high-Z (Pb) filters with variable thicknesses. The radiation output of the accelerator was kept constant for all beam energies. The image quality metrics was signal-to-noise ratio (SNR) of the particular sample over a particular background. It was found that the SNR depends on the above parameters in a complex way, but can be optimized by selecting a particular set of parameters. For some imaging setups increased filter thicknesses, while strongly absorbing the beams, increased the SNR of material decomposed images. Beam hardening due to polyenergetic x-ray spectra resulted in material decomposition errors, but this could be addressed using region of interest decomposition. It was shown that it is not feasible to separate the materials with close atomic numbers using the DE method. Particularly, Pb and U were difficult to decompose, at least at the dose levels allowed by radiation source and safety requirements.

  15. Dosimetry and image quality assessment in a direct radiography system

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Bruno Beraldo; Paixao, Lucas; Nogueira, Maria do Socorro, E-mail: boliveira.mg@gmail.com [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Oliveira, Marcio Alves de [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Fac. de Medicina. Dept. de Anatomia e Imagem; Teixeira, Maria Helena Araujo [Clinica Dra. Maria Helena Araujo Teixeira, Belo Horizonte, MG (Brazil)

    2014-11-15

    Objective: to evaluate the mean glandular dose with a solid state detector and the image quality in a direct radiography system, utilizing phantoms. Materials and methods: Irradiations were performed with automatic exposure control and polymethyl methacrylate slabs with different thicknesses to calculate glandular dose values. The image quality was evaluated by means of the structures visualized on the images of the phantoms. Results: considering the uncertainty of the measurements, the mean glandular dose results are in agreement with the values provided by the equipment and with internationally adopted reference levels. Results obtained from images of the phantoms were in agreement with the reference values. Conclusion: the present study contributes to verify the equipment conformity as regards dose values and image quality. (author)

  16. Safety of nursing staff and determinants of adherence to personal protective equipment

    OpenAIRE

    Neves,Heliny Carneiro Cunha; Souza,Adenícia Custódia Silva e; Medeiros,Marcelo; Munari,Denize Bouttelet; Ribeiro,Luana Cássia Miranda; Tipple,Anaclara Ferreira Veiga

    2011-01-01

    A qualitative study conducted in a teaching hospital with 15 nursing professionals. Attempted to analyze the reasons, attitudes and beliefs of nursing staff regarding adherence to personal protective equipment. Data were collected through focus groups, analyzed by the method of interpretation of meanings, considering Rosenstock’s model of health beliefs as a reference framework. Data revealed two themes: Occupational safety and Interpersonal Relationship. We identified several barriers that i...

  17. Safety analysis report for packaging onsite long-length contaminated equipment transport system

    International Nuclear Information System (INIS)

    McCormick, W.A.

    1997-01-01

    This safety analysis report for packaging describes the components of the long-length contaminated equipment (LLCE) transport system (TS) and provides the analyses, evaluations, and associated operational controls necessary for the safe use of the LLCE TS on the Hanford Site. The LLCE TS will provide a standardized, comprehensive approach for the disposal of approximately 98% of LLCE scheduled to be removed from the 200 Area waste tanks

  18. Safety analysis report for packaging, onsite, long-length contaminated equipment transport system

    Energy Technology Data Exchange (ETDEWEB)

    McCormick, W.A.

    1997-05-09

    This safety analysis report for packaging describes the components of the long-length contaminated equipment (LLCE) transport system (TS) and provides the analyses, evaluations, and associated operational controls necessary for the safe use of the LLCE TS on the Hanford Site. The LLCE TS will provide a standardized, comprehensive approach for the disposal of approximately 98% of LLCE scheduled to be removed from the 200 Area waste tanks.

  19. Radiography using californium-252 neutron sources

    International Nuclear Information System (INIS)

    Ray, J.W.

    1975-01-01

    The current status in the technology of neutron radiography using californium-252 neutron sources is summarized. Major emphasis is on thermal neutron radiography since it has the widest potential applicability at the present time. Attention is given to four major factors which affect the quality and useability of thermal neutron radiography: source neutron thermalization, neutron beam extraction geometry, neutron collimator dimensions, and neutron imaging methods. Each of these factors has a major effect on the quality of the radiographs which are obtained from a californium source neutron radiography system and the exposure times required to obtain the radiographs; radiograph quality and exposure time in turn affect the practicality of neutron radiography for specific nondestructive inspection applications. A brief discussion of fast neutron radiography using californium-252 neutron sources is also included. (U.S.)

  20. Quality and safety based management of radiological and clinical equipment

    International Nuclear Information System (INIS)

    Arora, S.; Saini, P.S.

    2001-01-01

    TQM (Total quality management) is the 'buzz' acronym expected in almost every aspect of industrial manufacturing, product development and services solicited by the outside agencies. The correct management of the many technological resources in health institutions in terms of efficiency, effectiveness and safety is a necessity in view of the criteria on which modern medicine is based. Almost all activities -be they diagnostic, therapeutic and rehabilitative - carried out within a modern hospital are based on widespread application of equipment and technology, the efficiency of which can directly influence the quality of service offered to the patient

  1. Double beam neutron radiography facility

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1977-09-01

    The DR1 reactor at Risoe is used as a neutron source for neutron radiography. In the double-beam neutron radiography facility a neutron flux of an intensity of 1.4 and 1.8 x 10 6 n. cm -2 . s -1 reaches the object to be radiographed. The transport and exposure container used for neutron radiography of irradiated nuclear fuel rods is described, and the exposure technique and procedure are reviewed. The mode by which single neutron radiographs are assembled and assessed is described. This report will be published in the ''Neutron Radiography Newsletter''. (author)

  2. Development of fast neutron radiography system based on portable neutron generator

    Energy Technology Data Exchange (ETDEWEB)

    Yi, Chia Jia, E-mail: gei-i-kani@hotmail.com; Nilsuwankosit, Sunchai, E-mail: sunchai.n@chula.ac.th [Department of Nuclear Engineering, Faculty of Engineering, Chulalongkorn University, Phayathai Rd., Patumwan, Bangkok, THAILAND 10330 (Thailand)

    2016-01-22

    Due to the high installation cost, the safety concern and the immobility of the research reactors, the neutron radiography system based on portable neutron generator is proposed. Since the neutrons generated from a portable neutron generator are mostly the fast neutrons, the system is emphasized on using the fast neutrons for the purpose of conducting the radiography. In order to suppress the influence of X-ray produced by the neutron generator, a combination of a shielding material sandwiched between two identical imaging plates is used. A binary XOR operation is then applied for combining the information from the imaging plates. The raw images obtained confirm that the X-ray really has a large effect and that XOR operation can help enhance the effect of the neutrons.

  3. Guidelines for evaluation of anchorage adequacy for safety-related equipment typically used on WWER-type NPPs

    International Nuclear Information System (INIS)

    Masopust, R.

    1999-01-01

    This report describes the criteria which should be met when the capacity evaluation of anchorage of safety related equipment is performed for the WWER type NPPs. It should be noted that these criteria were developed specifically for anchorage of WWER type equipment and components to the concrete or steel building structures and they cover different types of anchor bolts and other anchorage details which are typical just for the existing, constructed or reconstructed WWER type NPPs. The screening approach for verifying of equipment anchorage presented in this report is based on a combination of inspections, calculations, and engineering judgement

  4. Magnification radiography

    International Nuclear Information System (INIS)

    Genant, H.K.; Resnick, D.

    1988-01-01

    The relative clinical value of magnification compared with conventional radiography for skeletal applications is presented qualitatively. The presentation is based on the authors' experience with over 25,000 cases in which magnification has been used. For most areas in which magnification (optical or geometric) proves useful, subtle abnormalities of clinical importance are present at bone surfaces or at host-lesion interfaces. This is particularly true for arthritis and metabolic and infectious disorders of bone. In additional instances, serial assessment of the progression of disease or its response to therapy is enhanced by magnification. When gross abnormalities are present, as in most instances of trauma and bone dysplasia, the findings are obvious on conventional radiography, and magnification is not necessary. Thus, the magnification techniques appear to provide important diagnostic information, depending upon the anatomic part that is studied and the clinical question that is posed. It is also apparent that the demonstration of subtle skeletal abnormalities to clinical colleagues for educational purposes is greatly enhanced by magnification radiography

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... are the limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray ( ... leg (shin), ankle or foot. top of page What are some common uses of the procedure? A ...

  6. Transitioning to digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, F., E-mail: Francisco.Miranda@pwc.ca [Pratt & Whitney Canada, Longueuil, Quebec (Canada)

    2015-09-15

    This article provides insight on the technical and business considerations necessary to implement or to transition to digital radiography Continued refinements in digital radiography technology have resulted in significant improvements in image quality and detectability of indications. These improvements have resulted in the acceptance of the technology by users and aerospace primes for final product inspection and disposition. Digital radiography has also been identified as an interesting cost reduction initiative with the potential of providing gains in productivity through increased throughput and decreased inspection lead-times and resulting costs. (author)

  7. Recent developments in radiography

    International Nuclear Information System (INIS)

    Berger, Harold

    1982-01-01

    Advances in radiography are reviewed and eighty-one references are cited to provide additional information. The review includes information on x-ray sources in terms of output, portability and imaging geometry and detectors in terms of films and screens, electrostatic methods, real-time techniques and solid state devices. Inspection methods utilizing radiations other than x-rays, neutrons and charged particles, expand the inspection problems suitable for radiography. Techniques such as tomography, digital radiography and image enhancement are described. Tomography, in particular, provides excellent capability to characterize materials and discontinuities

  8. Digital radiography of the chest

    International Nuclear Information System (INIS)

    Sakurai, Kenji; Hachiya, Junichi; Korenaga, Tateo; Nitatori, Toshiaki; Miyasaka, Yasuo; Furuya, Yoshiro

    1984-01-01

    Initial clinical experience in digital chest radiography utilizing photostimulable phosphor and scanning laser stimulated luminescence was reported. Image quality of conventional film/screen radiography and digital radiography was compared in 30 normal cases. Reflecting wide dynamic range of the system, improved image quality was confirmed in all 30 cases, particularly in visibility of various mediastinal structures and pulmonary vessels. High sensor sensitivity of the system enabled digital radiography to reduce radiation dose requirement significantly. Diagnostically acceptable chest images were obtained with approximately 1/5 of routine dose for conventional radiography without significant image quality degradation. Some artifact created by digital processing were mostly overcome by a routine use of simultaneous display of two different types of image processing and therefore was not an actual drawback from diagnostic standpoint. Further technical advancement of the system to be seen for digital storage, retrieval and tranceference of images. (author)

  9. neutron radiography. Report prepared from contributions by members of the MOD Working Party on Neutron Radiography

    International Nuclear Information System (INIS)

    Halmshaw, R.

    1977-03-01

    Radiography with thermal or cold neutrons has some special advantages over X-rays and gamma rays, and some facilities for neutron radiography exist in the Ministry of Defence. This report gives a brief and simple description of the technique, its advantages and disadvantages, and is illustrated with a number of Ordnance applications taken from MOD work, to show examples where neutron radiographs provided extra important information not available from X- or gamma radiography. The facilities available in the UK for neutron radiography are listed. (author)

  10. Quality assurance in digital radiography

    International Nuclear Information System (INIS)

    Busch, H.P.; Lehmann, K.J.

    1989-01-01

    At present, there is no standard way of evaluating performance characteristics of digital radiography systems. Continuous measurements of performance parameters are necessary in order to obtain images of high quality. Parameters of quality assurance in digital radiography, which can be evaluated with simple, quick methods, are spatial resolution, low-contrast detectability, dynamic range and exposure dose. Spatial resolution was determined by a lead bar pattern, whereas the other parameters were measured by commercially available phantoms. Performance measurements of 10 digital subtraction angiography (DSA) units and one digital radiography system for unsubtracted digital radiography were assessed. From these results, recommendations for performance parameter levels will be discussed. (author)

  11. Improvement suggestions on license extension management for civil nuclear safety equipment activities

    International Nuclear Information System (INIS)

    Sun Xingjian; Liu Hongji; Han Guoli; Jia Fengcai

    2013-01-01

    Based on the concepts of Clear Requirements, Comprehensive Review, Objective Assessment, Dynamic Management, this paper gives improvement suggestions on license extension management for civil nuclear safety equipment design, manufacture, installation and non-destructive examination activities, which include establishing a relatively unified license extension review standard, combining multi-views and close linking license review and supervision, full utilizing the daily supervision and inspection results, as well as further improving motivation and elimination mechanism. (authors)

  12. Selenium-based digital radiography of the cervical spine. Comparison with screen-film radiography for the depiction of anatomic details

    International Nuclear Information System (INIS)

    Ludwig, K.; Diederich, S.; Wormanns, D.; Link, T.M.; Lenzen, H.; Heindel, W.

    2002-01-01

    Purpose: To compare selenium-based digital radiography with conventional screen-film radiography of the cervical spine. Materials and Methods: In a prospective study X-ray images of the cervical spine were obtained in 25 patients using selenium-based digital radiography and conventional screen-film radiography. All images were clinically indicated. Selenium-based digital radiography and conventional screen-film radiography were used in a randomized order. Four radiologists independently evaluated all 50 examinations for the visibility of 76 anatomic details according to a five-level confidence scale (1=not visible, 5=very good visibility). From the evaluation of these anatomic details scores for the upper and middle cervical spine, the cervicothoracic junction and the cervical soft tissues were calculated. The scores for selenium-based digital radiography and conventional screen-film radiography were compared using Wilcoxon's signed rank test. Results: From a total of 15,200 observations (608 per patient) the following scores were calculated for selenium-based digital radiography and for screen-film radiography, respectively: Upper cervical spine 3.88 and 3.94; middle cervical spine 4.60 and 4.48; cervico-thoracic junction 3.64 and 2.62; cervical soft tissue 4.47 and 3.46. The differences between the last two scores were statistically significant (p [de

  13. Flaw detection of welded joints in NPP equipment assembly

    International Nuclear Information System (INIS)

    Kesler, N.A.; Polevik, V.A.; Orlov, N.S.

    1984-01-01

    State of the art and prospects of development of ultrasonic and radiography testing of welded joints for quality used in NPP equipment assembly are considered. Recommendations are given on reducing the labour content with the use of these methods. Specifications for the developed facilities intended for automation and mechanization of the described quality control methods are presented

  14. The Design of Transportation Equipment in Terms of Human Capabilities. The Role of Engineering Psychology in Transport Safety.

    Science.gov (United States)

    McFarland, Ross A.

    Human factors engineering is considered with regard to the design of safety factors for aviation and highway transportation equipment. Current trends and problem areas are identified for jet air transportation and for highway transportation. Suggested solutions to transportation safety problems are developed by applying the techniques of human…

  15. Assessing the dose values received by patients during conventional radiography X-ray examinations and the technical condition of the equipment used for this purpose.

    Science.gov (United States)

    Bekas, Marcin; Pachocki, Krzysztof A; Waśniewska, Elżbieta; Bogucka, Dagmara; Magiera, Andrzej

    2014-01-01

    X-ray examination is associated with patient exposure to ionizing radiation. Dose values depend on the type of medical procedure used, the X-ray unit technical condition and exposure conditions selected. The aim of this study was to determine the dose value received by patients during certain conventional radiography X-ray examinations and to assess the technical condition of medical equipment used for this purpose. The study covered the total number of 118 conventional diagnostic X-ray units located in the Masovian Voivodeship. The methodology used to assess the conventional diagnostic X-ray unit technical condition and the measurement of the radiation dose rate received by patients are based on test procedures developed by the Department of Radiation Protection and Radiobiology of the National Institute of Public Health - National Institute of Hygiene (Warszawa, Poland) accredited for compliance with PN-EN 17025 standard by the Polish Centre for Accreditation. It was found that 84.7% of X-ray units fully meet the criteria set out in the Polish legislation regarding the safe use of ionizing radiation in medicine, while 15.3% of the units do not meet some of them. The broadest dose value range was recorded for adult patients. Particularly, during lateral (LATl) lumbar spine radiography the recorded entrance surface dose (ESD) values ranged from 283.5 to 7827 µGy (mean: 2183.3 µGy). It is absolutely necessary to constantly monitor the technical condition of all X-ray units, because it affects population exposure to ionizing radiation. Furthermore, it is essential to raise radiographers' awareness of the effects that ionizing radiation exposure can have on the human body.

  16. Radioisotopes - their applications in industrial radiography

    International Nuclear Information System (INIS)

    Rao, H.R.S.

    1977-01-01

    The nature of radioisotopes and their industrial applications with special reference to industrial radiography are outlined. The various aspects of industrial radiography such as source size, source containers, films, density of radiography, radiographic quality and applications are discussed in brief. (M.G.B.)

  17. Situation analysis of physical independence of the equipment and safety circuits of Almaraz NPP regarding R.G. 1.75 rev.3 (2005)

    International Nuclear Information System (INIS)

    Seijas Portela, S.

    2010-01-01

    Situation analysis of physical independence of the electrical equipment and circuits CN safety Almaraz about R.G. 1.75 rev. 3. (2005) The aim of this paper is to present the work done in the analysis of the physical separation of redundant safety electrical equipment (emergency diesel generators, medium voltage, electrical cabinets, etc.) and physical separation of circuits and electrical conduits.

  18. Safety equipment list for 241-C-106 waste retrieval, Project W-320: Revision 1

    International Nuclear Information System (INIS)

    Conner, J.C.

    1994-01-01

    The goals of the C-106 sluicing operation are: (1) to stabilize the tank by reducing the heat load in the tank to less than 42 MJ/hr (40,000 Btu/hour), and (2) to initiate demonstration of single-shell tank (SST) retrieval technology. The purpose of this supporting document (SD) is as follows: (1) to provide safety classifications for items (systems, structures, equipment, components, or parts) for the waste retrieval sluicing system (WRSS), and (2) to document and methodology used to develop safety classifications. Appropriate references are made with regard to use of existing systems, structures, equipments, components, and parts for C-106 single-shell transfer tank located in the C Tank Farm, and 241-AY-102 (AY-102) double shell receiver tanks (DST) located in the Aging Waste Facility (AWF). The Waste Retrieval Sluicing System consists of two transfer lines that would connect the two tanks, one to carry the sluiced waste slurry to AY-102, and the other to return the supernatant liquid to C-106. The supernatant, or alternate fluid, will be used to mobilize waste in C-106 for the sluicing process. The equipment necessary for the WRSS include pumps in each tank, sluicers to direct the supernatant stream in C-106, a slurry distributor in AY-102, HVAC for C-106, instrumentation and control devices, and other existing components as required

  19. Fresh-Core Reload of the Neutron Radiography (NRAD) Reactor with Uranium(20)-Erbium-Zirconium-Hydride Fuel

    Energy Technology Data Exchange (ETDEWEB)

    John D. Bess; Thomas L. Maddock; Margaret A. Marshall; Leland M. Montierth

    2011-03-01

    The neutron radiography (NRAD) reactor is a 250 kW TRIGA® (Training, Research, Isotopes, General Atomics) Mark II , tank-type research reactor currently located in the basement, below the main hot cell, of the Hot Fuel Examination Facility (HFEF) at the Idaho National Laboratory (INL). It is equipped with two beam tubes with separate radiography stations for the performance of neutron radiography irradiation on small test components. The 60-fuel-element operational core configuration of the NRAD LEU TRIGA reactor has been evaluated as an acceptable benchmark experiment. The initial critical configuration developed during the fuel loading process, which contains only 56 fuel elements, has not been evaluated as it is very similar to the evaluated core configuration. The benchmark eigenvalue is 1.0012 ± 0.0029. Calculated eigenvalues differ significantly (~±1%) from the benchmark eigenvalue and have demonstrated sensitivity to the thermal scattering treatment of hydrogen in the U-Er-Zr-H fuel.

  20. Fresh-Core Reload of the Neutron Radiography (NRAD) Reactor with Uranium(20)-Erbium-Zirconium-Hydride Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Bess, John D. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Maddock, Thomas L. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Marshall, Margaret A. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Montierth, Leland M. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zhang, Ning [Idaho National Lab. (INL), Idaho Falls, ID (United States); Phillips, Ann Marie [Idaho National Lab. (INL), Idaho Falls, ID (United States); Schreck, Kenneth A. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Briggs, J. Blair [Idaho National Lab. (INL), Idaho Falls, ID (United States); Woolstenhulme, Eric W. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Bolin, John M. [General Atomics, San Diego, CA (United States); Veca, Anthony [General Atomics, San Diego, CA (United States); McKnight, Richard D. [Argonne National Lab. (ANL), Argonne, IL (United States); Lell, Richard M. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2014-03-01

    The neutron radiography (NRAD) reactor is a 250 kW TRIGA® (Training, Research, Isotopes, General Atomics) Mark II , tank-type research reactor currently located in the basement, below the main hot cell, of the Hot Fuel Examination Facility (HFEF) at the Idaho National Laboratory (INL). It is equipped with two beam tubes with separate radiography stations for the performance of neutron radiography irradiation on small test components. The 60-fuel-element operational core configuration of the NRAD LEU TRIGA reactor has been evaluated as an acceptable benchmark experiment. The initial critical configuration developed during the fuel loading process, which contains only 56 fuel elements, has not been evaluated as it is very similar to the evaluated core configuration. The benchmark eigenvalue is 1.0012 ± 0.0029. Calculated eigenvalues differ significantly (~±1%) from the benchmark eigenvalue and have demonstrated sensitivity to the thermal scattering treatment of hydrogen in the U-Er-Zr-H fuel.

  1. Euratom Neutron Radiography Working Group

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    reactor fuel as well as establish standards for radiographic image quality of neutron radiographs. The NRWG meets once a year in each of the neutron radiography centers to review the progress made and draw plans for the future. Besides, ad-hoc sub-groups or. different topics within the field of neutron......In 1979 a Neutron Radiography Working Group (NRWG) was constituted within Buratom with the participation of all centers within the European Community at which neutron facilities were available. The main purpose of NRWG was to standardize methods and procedures used in neutron radiography of nuclear...... radiography are constituted. This paper reviews the activities and achievements of the NRWG and its sub-groups....

  2. Fracture healing: direct magnification versus conventional radiography

    International Nuclear Information System (INIS)

    Link, T.M.; Kessler, T.; Lange, T.; Overbeck, J.; Fiebich, M.; Peters, P.E.

    1994-01-01

    The aim of the study was to evaluate the potential of magnification radiography in diagnosing fracture healing and assessing its complications. Seventy-three patients with fractures or who had undergone osteotomy were radiographed with both conventional (non-magnified) and magnification (5-fold) techniques. Since 10 patients were radiographed twice and 1 three times, 83 radiographs using each technique were obtained. All radiographs were analysed and the findings correlated with the patients' follow-up studies. The microfocal X-ray unit used for magnification radiography had a focal spot size of 20-130 μm. As an imaging system, digital luminescence radiography was employed with magnification, while normal film-screen systems were used with conventional radiography. Magnification radiography proved superior to conventional radiography in 47% of cases: endosteal and periosteal callus formations were seen earlier and better in 26 cases, and osseous union could be evaluated with greater certainty in 33 cases. In 49% of cases magnification radiography was equal and in 4% inferior to conventional radiography. Additionally an ''inter-observer analysis'' was carried out. Anatomical and pathological structures were classified into one of four grades. Results were significantly (P < 0.01) better using magnification radiography. We conclude that the magnification technique is a good method for monitoring fracture healing in its early stages. (orig.)

  3. Accelerator safety program at the Lawrence Livermore Laboratory

    International Nuclear Information System (INIS)

    Graham, C.L.

    1976-01-01

    A proposed accelerator safety standard for the Lawrence Livermore Laboratory (LLL) is given. All accelerators will comply with this standard when it is included in the LLL Health and Safety Manual. The radiation alarm and radiation safety system for a radiography facility are also described

  4. First experience with digital radiography

    International Nuclear Information System (INIS)

    Buchmann, F.

    1987-01-01

    The digital radiogram is explained, its advantages being the various possibilities of image processing, loss-free transmission, recording and storage capabilities, and in special cases, prompt availability of processed images. Digital subtraction angiography (DSA) and the high-resolution method of digital, luminescent radiography, which replaced the conventional film-foil radiography, are explained as the first developments for the introduction of digital radiography, which today already is an applicable technique. (orig./MG) [de

  5. Problems associated with digital luminescence radiography in the neonate and young infant. Problems with digital radiography.

    Science.gov (United States)

    Arthur, R J; Pease, J N

    1992-01-01

    An evaluation of the Siemens Digiscan has been undertaken to determine whether digital luminescence radiography (DLR) could replace conventional radiography in the examination of the neonate and young infant. Whilst the overall image quality of the digital radiograph was consistently higher than for conventional radiography the difference was less marked than we had expected. Furthermore, the potential for reduction in radiation dose by reducing the repeat rate due to incorrect exposure was limited. The potential advantages of DLR have been critically examined in relationship to neonatal radiography and a number of problems encountered during the evaluation have been highlighted.

  6. Experience in industrial radiography equipment into carry out inspections in Brazil

    International Nuclear Information System (INIS)

    Lopes, Valdir Maciel; Silva, Joao

    2008-01-01

    The Nuclear and Energy Research Institute (IPEN), in accordance with the attributions given by the National Commission of Nuclear Energy (CNEN), has been supplying the market with radioactive sealed sources of Iridium 192 ( 192 Ir), for Brazil and some South America Countries, for more than 24 years. In this period, the experience acquired in the accompanied of the technological improvement in the industrial gammagraphy equipment; into Sealed Sources Production Laboratory (LPFS) will be show. Of the set of operations carry out in the LPFS, since the assemblies, tests of qualification of the sources also inspection at of the equipment for posterior applications in field, it is intended to demonstrate to the technological improvement associate to the radiological and operational security. In this work, the data base of the system of the LPFS will be used, as well as the professional experience of the laboratory team in the daily relationship with the companies responsible for the equipment operation. (author)

  7. Incident in industrial gamma radiography in Argentina

    International Nuclear Information System (INIS)

    Alonso Jimenez, Maria T.; Ermacora, Marcela

    2008-01-01

    In the present work a description of an industrial gamma radiography incident is made and an analysis of the events which led to it is presented. The event took place during a routine regulatory inspection carried out by personnel of the Nuclear Regulatory Authority in the year 2004 to a storage facility of projectors and containers belonging to a company licensed to operate gamma radiography equipment. On arriving to the store authorized by the ARN, placed in an industrial site, it was verified that it was empty and without surveillance. The inspectors contacted the person responsible for radiological protection, who went to the place and declared that the totality of the equipment and radioactive sources had been moved to a private country house. The reason for this change, according to the statement, was that the company had gone bankrupt and the authorized storage facility had remained without surveillance and without personnel in charge. In the country house, inside the room meant as a store, high environmental equivalent dose rates were detected. After verifying the dose rates in each of the projectors, it was checked that one of them measured high dose rates. For this reason, it was isolated and the source recovery was done, due to the suspicion that it had remained in a non-shielded position. After projecting it several times towards a lead container due to the fact that high dose rates were still being measured, the person responsible for radiological protection proceeded to extract the source from the guide tube, finding that it had been transferred in the reverse order. According to the record of movements of equipment and radioactive sources of the company, the source transference had been done, in the previous store in the month of March 2004, by a radiographer who did not work at the company any longer and whose permit had expired. The results of the estimations of the doses received during the process of the source recovery are presented. Finally, an

  8. An on-line monitoring system for navigation equipment

    Science.gov (United States)

    Wang, Bo; Yang, Ping; Liu, Jing; Yang, Zhengbo; Liang, Fei

    2017-10-01

    Civil air navigation equipment is the most important infrastructure of Civil Aviation, which is closely related to flight safety. In addition to regular flight inspection, navigation equipment's patrol measuring, maintenance measuring, running measuring under special weather conditions are the important means of ensuring aviation flight safety. According to the safety maintenance requirements of Civil Aviation Air Traffic Control navigation equipment, this paper developed one on-line monitoring system with independent intellectual property rights for navigation equipment, the system breakthroughs the key technologies of measuring navigation equipment on-line including Instrument Landing System (ILS) and VHF Omni-directional Range (VOR), which also meets the requirements of navigation equipment ground measurement set by the ICAO DOC 8071, it provides technical means of the ground on-line measurement for navigation equipment, improves the safety of navigation equipment operation, and reduces the impact of measuring navigation equipment on airport operation.

  9. Neutron-induced alpha radiography

    International Nuclear Information System (INIS)

    Pereira, Marco Antonio Stanojev

    2008-01-01

    A new radiography technique to inspect thin samples was developed. Low energy alpha particles, generated by a boron based screen under thermal neutron irradiation, are used as penetrating radiation. The solid state nuclear track detector CR-39 has been used to register the image. The interaction of the α - particles with the CR-39 gives rise to damages which under an adequate chemical etching became tracks the basic units forming the image. A digital system was developed for data acquisition and data analysis as well as for image processing. The irradiation and etching conditions to obtain the best radiography are 1,3 hours and 25 minutes at 70 deg C respectively. For such conditions samples having 10 μm in thickness can be inspected with a spatial resolution of 32 μm. The use of the digital system has reduced the time spent for data acquisition and data analysis and has improved the radiography image visualization. Furthermore, by using the digital system, it was possible to study several new parameters regarding the tracks which are very important to understand and study the image formation theory in solid state nuclear track detectors, the one used in this thesis. Some radiography images are also shown which demonstrate the potential of the proposed radiography technique. When compared with the other radiography techniques already in use to inspect thin samples, the present one developed in the present paper allows a smaller time to obtain the image, it is not necessary to handle liquid radioactive substances, the detector is insensitive to β, γ, X-ray and visible light. (author)

  10. Radiation Effects in Paediatric radiography

    International Nuclear Information System (INIS)

    Mutwasi, O.

    2006-01-01

    Diagnostic imaging has evolved from single technique to a field which we have a choice from many modalities. Some without radiation. Radiation producing modalities include plain films (low dose), Fluoroscopy (mid range dose), Computed tomography (high dose). Radiography dose can significantly be influenced in plain radiography by varying speed of screens, cassette construction and type of radiography. E.g. digital or computed. In computed or digital radiography we are no longer able to tell h igh dose b y the quality of images. The final image is by great extend a product of post processing algorithms. It's for this reasons that the basic understanding of the sensitivity and specifying of various types of examinations and of specifically radiation effects is mandatory for a paediatric imager

  11. Safety equipment list for the light duty utility arm system

    International Nuclear Information System (INIS)

    Barnes, G.A.

    1998-01-01

    The initial issue (Revision 0) of this Safety Equipment List (SEL) for the Light Duty Utility Arm (LDUA) requires an explanation for both its existence and its being what it is. All LDUA documentation leading up to creation of this SEL, and the SEL itself, is predicated on the LDUA only being approved for use in waste tanks designated as Facility Group 3, i.e., it is not approved for use in Facility Group 1 or 2 waste tanks. Facility Group 3 tanks are those in which a spontaneous or induced hydrogen gas release would be small, localized, and would not exceed 25% of the LFL when mixed with the remaining air volume in the dome space; exceeding these parameters is considered unlikely. Thus, from a NFPA flammable gas environment perspective the waste tank interior is not classified as a hazardous location. Furthermore, a hazards identification and evaluation (HNF-SD-WM-HIE-010, REV 0) performed for the LDUA system concluded that the consequences of actual LDUA system postulated accidents in Flammable Gas Facility Group 3 waste tanks would have either NO IMPACT or LOW IMPACT on the offsite public and onsite worker. Therefore, from a flammable gas perspective, there is not a rationale for classifying any of SSCs associated with the LDUA as either Safety Class (SC) or Safety Significant (SS) SSCs, which, by default, categorizes them as General Service (GS) SSCs. It follows then, based on current PHMC procedures (HNF-PRO-704 and HNF-IP-0842, Vol IV, Section 5.2) for SEL creation and content, and from a flammable gas perspective, that an SEL is NOT REQ at sign D HOWEVER exclamation point exclamation point exclamation point There is both a precedent and a prudency to capture all SSCS, which although GS, contribute to a Defense-In-Depth (DID) approach to the design and use of equipment in potentially flammable gas environments. This Revision 0 of the LDUA SEL has been created to capture these SSCs and they are designated as GS-DID in this document. The specific reasons for

  12. Neutron radiography of Apollo ordnance

    International Nuclear Information System (INIS)

    Golliher, K.G.

    1983-01-01

    Neutron radiography played an important role in the successful Apollo missions. Neutron radiography was used, for the first time, on a production basis to examine the internal details of ordnance devices employed in the Apollo Program. Ordnance devices ranged from charges which separated the massive booster stages to those which triggered the release of re-entry parachutes. Discussed are the early developments in neutron radiography and the conversion of this infant nondestructive technology into production capabilities. (Auth.)

  13. Technical and diagnostic problems of X-ray radiography of children in medical practice

    International Nuclear Information System (INIS)

    Schuster, W.

    An increase in biomedical paediatric radiography of 5-10% per year is expected and therefore it is necessary to look for new possibilities to reduce the dose with the aim to make an increase of radiation exposure impossible, a radiation exposure which would indeed have a very negative effect on the organism of children. Some reasons for the increased radiation sensivity of children are explained. To reduce the radiation exposure the author demands for the sector of children radiobiology that doctors and assistents should be trained in a right way, further a clear diagnosis and the best possible equipment. Concerning the last point various possibilities are presented. The special problem of biomedical radiography is shortly dealt with. At the end of his report the author gives some recommendations concerning the dose, dose capacity, filters which should be used. (MG) [de

  14. Proton radiography using highpower femtosecond laser

    International Nuclear Information System (INIS)

    Choi, Chang Il

    2010-08-01

    A femtosecond laser emits pulses whose width is between few and few hundreds femtoseconds (10 -15 s). The production mechanism of the high energy protons generated by the femtosecond laser is not clear so far, but the technologies have been improving. The applications using the generated protons are the proton therapy, proton radiography, nuclear physics, security inspection, and so on. Especially in the radiography, the laser-generated protons are very useful to obtain high quality images of thin objects, because protons are able to penetrate an object following an almost straight path and give a depth distribution information of various elements in a subject. Since the laser-driven protons require lower cost and smaller facility than accelerator-based protons, the radiography using laser-driven protons have been of interest. In this research, we have performed the radiography experiments by using protons generated by the 100 TW titanium sapphire femtosecond laser facility of Advanced Photonics Research Institute (APRI) of Gwangju Institute of Science Technology (GIST). A CR-39 Solid State Nuclear Track Detector (SSNTD) has been used as radiography screen. The radiography digital images have been obtained by using an optical microscope and a CCD camera. Modulation Transfer Function (MTF) has been derived from analyzing the obtained images, and the spatial resolution of the images have been evaluated. And, we have performed the radiography experiments of monoenergetic proton from the Tandem Van de Graaff accelerator of Korea Institute of Geoscience and Mineral Resources (KIGAM). We have obtained and compared the radiography images from other proton production methods which are the laser and the accelerator, respectively. And also, we have found out the optimized chemical etching condition, in order to improve the spatial resolution of the radiography images. Finally, the evaluated maximum spatial resolution of the images are 2.09 μm

  15. Image Acquisition and Quality in Digital Radiography.

    Science.gov (United States)

    Alexander, Shannon

    2016-09-01

    Medical imaging has undergone dramatic changes and technological breakthroughs since the introduction of digital radiography. This article presents information on the development of digital radiography and types of digital radiography systems. Aspects of image quality and radiation exposure control are highlighted as well. In addition, the article includes related workplace changes and medicolegal considerations in the digital radiography environment. ©2016 American Society of Radiologic Technologists.

  16. Assessment of Nugget Size of Spot Weld using Neutron Radiography

    Directory of Open Access Journals (Sweden)

    Triyono

    2011-08-01

    Full Text Available Resistance spot welding (RSW has been widely used for many years in the fabrication of car body structures, mainly due to the cost and time considerations. The weld quality as well as the nugget size is an issue in various manufacturing and processes due to the strong link between the weld quality and safety. It has led to the development of various destructive and non-destructive tests for spot welding such as peel testing, ultrasonic inspections, digital shearography, and infrared thermography. However, such methods cannot show spot weld nugget visually and the results are very operator’s skill dependent. The present work proposes a method to visualize the nugget size of spot welds using neutron radiography. Water, oil and various concentrations of gadolinium oxide-alcohol mixture were evaluated as a contrast media to obtain the best quality of radiography. Results show that mixture of 5 g gadolinium oxide (Gd2O3 in 25 ml alcohol produces the best contrast. It provides the possibility to visualize the shape and size of the nugget spot weld. Furthermore, it can discriminate between nugget and corona bond. The result of neutron radiography evaluation shows reasonable agreement with that of destructive test.

  17. Strategy for conformity of non-standard cryogenic equipment

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    CERN as an intergovernmental organization establishes its own Safety Rules as necessary for its proper functioning. In particular, the CERN General Safety Instruction for cryogenic equipment requires that cryogenic pressure equipment at CERN shall comply with the European Pressure Equipment Directive (PED). However, due to the particular features of some of the cryogenic equipment required for the accelerators, as well as the existence of international collaborations with in-kind contributions from non-EU countries, full compliance with the PED may not always be achieved. This situation is foreseen in the Safety Rules, where CERN HSE will define the Safety requirements applicable to such equipment as well as any eventual additional compensatory measure as to ensure a commensurate level of Safety for our pressure equipment. Where compliance with PED may not be achieved, CERN HSE will become the de facto Notified Body and therefore be in charge of the assessment of the conformity of the equipment to the applica...

  18. Charter of good practices in industrial radiography; Charte de bonnes pratiques en radiographie industrielle

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    This document describes good practices in the field of industrial radiography. After having presented the main prevention and radiation protection principles, the actors inside and outside of the company, and actors intervening during an operation subcontracting in industrial radiography, this report analyzes the activity: prerequisites for work preparation, prevention coordination, work preparation, transportation, work achievement, return on experience. It addresses personnel training and information, and the dosimetric and medical monitoring of technicians in industrial radiography. Some aspects are addressed in appendix: principles (justification, optimization, and limitation), regulations, intervention form, exposure form, and so on

  19. Inspection reliability comparison of digital radiography, film radiography and radioscopy for inspection of Inconel welds

    International Nuclear Information System (INIS)

    Meade, W.; Kidwell, C.; Warren, G.

    2004-01-01

    Digital Radiography offers the promise of economic and environmental advantages over traditional film based inspection. Boeing Commercial Aircraft Group has an on-going effort to evaluate this emerging radiographic method for production of aerospace hardware. Included in this effort was a program to evaluate the potential for utilizing amorphous silicon based digital radiography for the inspection of inconel weldments in engine ducting. For this particular program, probability of detection (POD) studies were conducted to compare the reliability of digital radiography with the existing production processes that utilize film radiography and image-intensifier based radioscopy. Cycle time studies were also conducted to determine the potential economic benefit for switching to the new process. The methodology and findings of this comparison are presented. (author)

  20. Inspection reliability comparison of digital radiography, film radiography and radioscopy for inspection of Inconel welds

    Energy Technology Data Exchange (ETDEWEB)

    Meade, W.; Kidwell, C.; Warren, G. [Boeing Commercial Aircraft Group, Renton, Washington (United States)

    2004-07-01

    Digital Radiography offers the promise of economic and environmental advantages over traditional film based inspection. Boeing Commercial Aircraft Group has an on-going effort to evaluate this emerging radiographic method for production of aerospace hardware. Included in this effort was a program to evaluate the potential for utilizing amorphous silicon based digital radiography for the inspection of inconel weldments in engine ducting. For this particular program, probability of detection (POD) studies were conducted to compare the reliability of digital radiography with the existing production processes that utilize film radiography and image-intensifier based radioscopy. Cycle time studies were also conducted to determine the potential economic benefit for switching to the new process. The methodology and findings of this comparison are presented. (author)

  1. Equipment Qualification and Environment Establishment for COTS Dedication of Safety Grade PC

    International Nuclear Information System (INIS)

    Ahn, Kwang Chul; Bin, Chang Sun; Kwon, Yoon Kwang; Kang, Shin Woo; Koh, Sung Won; Shon, Eui Chan; Jang, Hyun Doo; Song, Il Sup; Lee, Hyun Noh

    2010-08-01

    Safety grade PCs are required for protection systems of SKN 3 and 4 nuclear power plant and subsequent plants. Commercial grade item (CGI) dedication should be carried out to utilize a commercial PC as a safety grade PC of nuclear power plants. This project is aimed to perform the equipment qualification of the commercial PC, and review and improve the quality system of the PC supplier. As a result of the EQ for the CGI dedication, selected military PCs have passed the environment test, the seismic test, and the EMI test required for the digital controllers of nuclear plants. In addition, a walk-through of the quality system of the PC supplier, ISO 9001, was carried out and the quality system was improved. History data for the PC was gathered. As the analysis of the history data showed that operating experience time of the PC is longer than the plant life time, the history data could be used as an evidence of acceptance. After dedicated according to the CGI dedication process, military rugged PCs could be used for safety grade PCs

  2. Comparison of the efficacy of conventional radiography, digital radiography, and ultrasound in diagnosing periapical lesions.

    Science.gov (United States)

    Raghav, Namita; Reddy, Sujatha S; Giridhar, A G; Murthy, Srinivas; Yashodha Devi, B K; Santana, N; Rakesh, N; Kaushik, Atul

    2010-09-01

    The aim of this study was to evaluate the efficacy of conventional radiography, digital radiography and ultrasound imaging in diagnosing periapical lesions. Twenty-one patients aged between 15 and 45 years with well defined periapical radiolucency associated with anterior maxillary or mandibular teeth requiring endodontic surgery or extraction were selected and consented to the study. Preoperative intraoral periapical radiographs and digital images using charge-coupled device obtained by paralleling technique were assessed by 3 specialist observers who gave their diagnosis of the periapical lesions. Then ultrasound examination was performed and the images were assessed for size, contents, and vascular supply by 3 ultrasonographers. It was followed by curettage of periapical tissues to enable histopathologic investigation, which is the gold standard in diagnosis. The data were statistically analyzed using SPSS, analysis of variance, and kappa statistics. The percentage accuracy of diagnosing periapical lesions using conventional radiography was 47.6%, digital radiography 55.6%, and ultrasound 95.2%. Ultrasound had the highest sensitivity and specificity: 0.95 and 1.00, respectively. Conventional and digital radiography enable diagnosis of periapical diseases, but not their nature, whereas ultrasound provides accurate information on the pathologic nature of the lesions, which is of importance in predicting the treatment outcome. Therefore ultrasound can be used as an adjunct to conventional or digital radiography in diagnosing periapical lesions. Copyright (c) 2010 Mosby, Inc. All rights reserved.

  3. Constancy check of beam quality in conventional diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Costa, Alessandro M.; Badin, Romulo S.; Leite, Marina S.; Caldas, Linda V.E.

    2008-01-01

    A tandem ionization chamber was developed for quality control programs of X-ray equipment used in conventional radiography and mammography. A methodology for the use of the tandem chamber in the constancy check of diagnostic X-ray beam qualities was established. The application at a medical X-ray imaging facility of this established methodology is presented. The use of the tandem chamber in the constancy check of diagnostic X-ray beam qualities is a useful method to control the performance of the X-ray equipment

  4. Neutron radiography by using JSW baby cyclotron

    International Nuclear Information System (INIS)

    Toda, Yojiro

    1995-01-01

    At present, JSW baby cyclotrons are mostly used for the production of the radioisotopes for medical use. The attempt to use this baby cyclotron for neutron radiography began already in 1981. The feasibility of the neutron radiography for the explosives in metallic cases which are used for H1 rockets was investigated. In 1983, it was shown that the neutron radiography by using the baby cyclotron in Muroran Works, Japan Steel Works, Ltd. was able to be carried out as a routine work. Since then, the nondestructive inspection by neutron radiography has been performed for rocket pyrotechnic articles, and contributed to heighten their reliability. Further, the radiography by using fast neutrons was developed and put to practical use for recent large H2 rockets. The JSW baby cyclotron BC 168 which has been used for neutron radiography can accelerate 16 MeV protons or 8 MeV deuterons up to 50 μA. The principle of thermal neutron radiography is the generation of fast neutrons by irradiating a Be target with the proton beam accelerated by a baby cyclotron, the moderation of the fast neutrons, the formation of the thermal neutron flux of uniform distribution with a collimator, the thermal neutron flux hitting the Gd plate in a film cassette through an object, and the exposure of an X-ray film to electrons from the Gd plate. Fast neutron radiography apparatus, and commercial neutron radiography are described. (K.I.)

  5. Comparison and Analysis of IEEE 344 and IEC 60980 standards for harmonization of seismic qualification of safety-related equipment

    International Nuclear Information System (INIS)

    Lee, Young Ok; Kim, Jong Seog; Seo, Jeong Ho; Kim, Myung Jun

    2011-01-01

    The seismic qualification of safety related equipment in nuclear power plants should demonstrate an equipment's ability to perform its safety function during/or after the time it is subjected to the forces resulting from one SSE. In addition, the equipment must withstand the effects of a number of OBEs, preceding the SSE. IEEE 344 and IEC 60980 present the criteria for establishing procedures demonstrating that the Class 1E equipment can meet its performance requirement during seismic events. Currently, IEEE 344 is used for regulation of nuclear power plant in the United State whereas IEC 60980 is mainly used in Europe. In particular, NPPs of France and China apply with RCC-E and GB that are domestic standards, respectively. Equipment supplier and Utility have difficulties because of different applicable standards. Equipment supplier to export S/R components/equipment to other standard area performs additional seismic qualification. For example, equipment are qualifies according to IEC 60980, RCC-E, GB although they have been qualified in accordance with IEEE 344. Also, utility to attempt power up-rate, life extension of NPP constructed under rules of RCC-E such as Ulchin NPP 1 and 2 has similar difficulties. RCC-E endorses IEC 60980 and GB is almost same as IEC 60980 except minor difference of earthquake environment definition. Therefore this paper surveys the similarities and differences between IEEE 344 and IEC 60980. In addition, this paper considers how the two sets of standards may be used in a complementary fashion to be possible using one or the other standard area

  6. Digital radiography is promising in industrial testing

    International Nuclear Information System (INIS)

    Del Fabbro, F.

    2015-01-01

    Digital radiography has recently entered the industrial world as a tool for non-destructive testing. There are 3 types of digital radiography: computed radiography (CR), direct radiography (DR) and computed tomography (CT). In computed radiography, traditional silver-halide films are replaced by photostimulable phosphor imaging plates that are activated through laser scanning and digitized. Direct radiography uses a flat panel detector (FPD) composed of X-ray detectors that performs an immediate digital conversion of the image that can be read by a computer. DR is a perfect tool for industrial testing but the fragility of the FPD panels reduces its uses. Computed tomography is based on the principle of DR to get data corresponding to successive cross-section images of the object. These data are processed by a software to get a 3-dimensional image of the object. CT was first developed for medical use but requires some improvement to become more accurate, faster, particularly for big objects. In recent years DR has enjoyed the highest growth rate in digital radiography. (A.C.)

  7. New medical application: nuclear scattering radiography

    International Nuclear Information System (INIS)

    Saudinos, J.

    1977-01-01

    Nuclear scattering of 1 GeV protons is used to obtain three dimensional radiographies with a volume resolution of about 1 mm 3 . The information is different from the one given by X-ray radiographies and in particular one may get radiographies of the hydrogen included in objects. Results on a vertebral column and a 'sella turcica' are presented [fr

  8. Personal Protective Equipment

    National Research Council Canada - National Science Library

    1998-01-01

    ... of personal protective equipment A safety program for new employees is a necessary part of any orientation program An on-going safety program should be used to motivate employees to continue to use...

  9. Evaluation of skin exposure of patients and the irradiation field dimensions in dental radiography

    International Nuclear Information System (INIS)

    Khoury, H.J.; Hazin, C.A.; Andrade Lima, F.R.; Lopes Filho, F.J.

    1991-01-01

    This work aimed to estimate the skin exposure to patients in dental radiography, as well as, evaluate the magnitude of the skin area irradiated during a typical radiographic procedure. The study was based in a preliminary survey of dental X-ray equipments installed in the metropolitan region of Recife. The results showed that in 90% of the equipments surveyed the estimated patient skin exposure was above the recommended value of 500 mR. For X-ray beam diameters, the results showed values ranging from 4.5 to 11.5 cm, which do not agree with those set up by either national or international radiation protection organizations. (author)

  10. Reliability analysis of PLC safety equipment

    Energy Technology Data Exchange (ETDEWEB)

    Yu, J.; Kim, J. Y. [Chungnam Nat. Univ., Daejeon (Korea, Republic of)

    2006-06-15

    FMEA analysis for Nuclear Safety Grade PLC, failure rate prediction for nuclear safety grade PLC, sensitivity analysis for components failure rate of nuclear safety grade PLC, unavailability analysis support for nuclear safety system.

  11. Reliability analysis of PLC safety equipment

    International Nuclear Information System (INIS)

    Yu, J.; Kim, J. Y.

    2006-06-01

    FMEA analysis for Nuclear Safety Grade PLC, failure rate prediction for nuclear safety grade PLC, sensitivity analysis for components failure rate of nuclear safety grade PLC, unavailability analysis support for nuclear safety system

  12. Industrial radiography on radiographic paper

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1977-11-01

    An investigation was performed to compare the quality of radiographic paper with that of X-ray film, after a review had been made of the rather scarce literature on the subject. The equipment used throughout the investigation is described, and characteristic curves for Agfa-Gevaert and Kodak papers exposed with different intensifying screens in the low and intermediate voltage range are reproduced. The relative speed, contrast and exposure latitude were computed from these curves. The quality of the radiographic image was checked on U/Al blocks and plates, Al and Fe blocks, and fiber-reinforced composites. Exposure charts for Al and Fe were made for various paper and screen combinations. Both the sharpness of the radiographic image as well as the influence of processing on speed and contrast were checked. Examples are given of the practical application of the paper for radiography of castings, weldings, solderings, assemblies, etc. (author)

  13. Neutron radiography with the cyclotron

    International Nuclear Information System (INIS)

    Tazawa, Shuichi; Asada, Yorihisa; Yano, Munehiko; Nakanii, Takehiko.

    1985-01-01

    Neutron radiography is well recognized as a powerful tool in nondestructive testing, but not widely used yet owing to lack of high intense thermal neutron source convenient for practical use. This article presents a new neutron radiograph facility, utilizing a sub-compact cyclotron as neutron source and is equipped with vertical and horizontal irradiation ports. The article describes a series of experiments, we conducted using beams of a variable energy cyclotron at Tohoku University to investigate the characteristics of thermal neutron obtained from 9 Be(p, n) reaction and thermalized by elastic scattering process. The article also describes a computer simulation of neutron moderator to analyze conditions getting maximal thermal neutron flux. Further, some of practical neutron radiograph examinations of aero-space components and museum art objects of classic bronze mirror and an attempt realizing real time imaging technique, are introduced in the article. (author)

  14. Optimization of the radiological protection of patients undergoing radiography, fluoroscopy and computed tomography. Final report of a coordinated research project in Africa, Asia and eastern Europe

    International Nuclear Information System (INIS)

    2004-12-01

    Although radiography has been an established imaging modality for over a century, continuous developments have led to improvements in technique resulting in improved image quality at reduced patient dose. If one compares the technique used by Roentgen with the methods used today, one finds that a radiograph can now be obtained at a dose which is smaller by a factor of 100 or more. Nonetheless, some national surveys, particularly in the United Kingdom and in the United States of America in the 1980s and 1990s, have indicated large variations in patient doses for the same diagnostic examination, in some cases by a factor of 20 or more. This arises not only owing to the various types of equipment and accessories used by the different health care providers, but also because of operational factors. The IAEA has a statutory responsibility to establish standards for the protection of people against exposure to ionising radiation and to provide for the worldwide application of those standards. A fundamental requirement of the International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources (BSS), issued by the IAEA in cooperation with the FAO, ILO, WHO, PAHO and NEA, is the optimization of radiological protection of patients undergoing medical exposure. Towards its responsibility of implementation of standards and under the subprogramme of radiation safety, in 1995, the IAEA launched a coordinated research project (CRP) on radiological protection in diagnostic radiology in some countries in the Eastern European, African and Asian region. Initially, the CRP addressed radiography only and it covered wide aspects of optimisation of radiological protection. Subsequently, the scope of the CRP was extended to fluoroscopy and computed tomography (CT), but it covered primarily situation analysis of patient doses and equipment quality control. It did not cover patient dose reduction aspects in fluoroscopy and CT. The project

  15. Digital Radiography in Kenya today

    International Nuclear Information System (INIS)

    Omenta, E.N.

    2006-01-01

    Its nearly one year and a half since digital imaging/radiography was introduced in Kenya mainly in Nairobi. the technology is becoming an increasingly effective and acceptable modality of producing radiographs from the traditional conventional radiography in use to date. the digital radiography offers numerous advantages that have been noted for the short period over the conventional way. For instance radiographs are produced in real time (less than 3 minutes), by so doing the technology has eliminated the wait for the processing period. the radiation exposure to the patient under the radiological examination is reduced as much as 90% from the traditional conventional film taking. The cost, labour and record-keeping necessary to maintain a chemical processor and darkroom operations are as well eliminated. The cost of purchasing and disposing of film wastes/darkroom processing chemicals, which are environmentally hazardous, also become unnecessary.digital radiography technology makes the digital images comparable to other images on the screen at that instant making both the patient and the clinician easily access images when needed. digital receptors have also replaced the cassette containing intensifying screens and film that is used in conventional radiography

  16. Diagnostic radiography: A study in distancing

    International Nuclear Information System (INIS)

    Reeves, Pauline J.; Decker, Sola

    2012-01-01

    Aims: This article aims to explore the ways in which diagnostic radiographers use distancing as a tool for emotional management in radiography practice. Methods: This review utilises data from oral history interviews undertaken as part of a larger study documenting the oral history of the diagnostic radiography profession in the United Kingdom as recounted by 24 participants. Results: The results are presented as illustrative of various aspects of the role of the diagnostic radiographer including the initial choice of diagnostic radiography as a profession, the endemic use of particular terminology, the nature of the encounter in diagnostic radiography (including that of sectional imaging) and whether the role is really patient-centred. Conclusions: The article concludes by suggesting that distancing from the patient is mediated by the need for physical touch in order to position the patient for radiography and also makes the suggestion that those opting for diagnostic radiography as a career may do so because they want a profession which is more distanced from the patient and that, even where this is not the case initially, individuals are socialised into adopting the ‘feeling rules’ of the profession. The article concludes by outlining potential areas for further research.

  17. Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures

    Energy Technology Data Exchange (ETDEWEB)

    Peer, Siegfried; Neitzel, Ulrich; Giacomuzzi, Salvatore M.; Pechlaner, Sigurd; KUenzel, Karl Heinz; Peer, Regina; Gassner, Eva; Steingruber, Iris; Gaber, O.; Jaschke, Werner

    2002-04-01

    AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the performance of caesium iodide/amorphous silicon flat panel detector exceeds state of the art storage phosphor radiography. This makes it well suited for skeletal imaging particularly in trauma as seen in the detection of wrist fractures. Peer, S. et al. (2002)

  18. Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures

    International Nuclear Information System (INIS)

    Peer, Siegfried; Neitzel, Ulrich; Giacomuzzi, Salvatore M.; Pechlaner, Sigurd; KUenzel, Karl Heinz; Peer, Regina; Gassner, Eva; Steingruber, Iris; Gaber, O.; Jaschke, Werner

    2002-01-01

    AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the performance of caesium iodide/amorphous silicon flat panel detector exceeds state of the art storage phosphor radiography. This makes it well suited for skeletal imaging particularly in trauma as seen in the detection of wrist fractures. Peer, S. et al. (2002)

  19. New Safety rules

    CERN Multimedia

    Safety Commission

    2008-01-01

    The revision of CERN Safety rules is in progress and the following new Safety rules have been issued on 15-04-2008: Safety Procedure SP-R1 Establishing, Updating and Publishing CERN Safety rules: http://cern.ch/safety-rules/SP-R1.htm; Safety Regulation SR-S Smoking at CERN: http://cern.ch/safety-rules/SR-S.htm; Safety Regulation SR-M Mechanical Equipment: http://cern.ch/safety-rules/SR-M.htm; General Safety Instruction GSI-M1 Standard Lifting Equipment: http://cern.ch/safety-rules/GSI-M1.htm; General Safety Instruction GSI-M2 Standard Pressure Equipment: http://cern.ch/safety-rules/GSI-M2.htm; General Safety Instruction GSI-M3 Special Mechanical Equipment: http://cern.ch/safety-rules/GSI-M3.htm. These documents apply to all persons under the Director General’s authority. All Safety rules are available at the web page: http://www.cern.ch/safety-rules The Safety Commission

  20. Ecological and economical solutions for film radiography

    International Nuclear Information System (INIS)

    Marstboom, K.

    2004-01-01

    Film radiography may be perceived as technology with environmental concerns, involving the application of chemicals and the discharge of drained waters with high silver levels. Ecological legislation concerning silver content of the wash water differs from country to country. GE Inspection Technologies now offers industrial radiographers several ways to address regulatory limits silver in drained waters. First, two brand new film processors, the Agfa NDT Si and M eco, are introduced to the NDT market. Both machines are equipped with Cascade Fixing Technology, which reduces silver content in the wash water and increases the ability to comply with stricter discharge standards. Next the new eco Film System is presented. This system is based on the new machines, specially adapted films and carefully developed new chemicals. Eco stands for ecological and economic performance. The customer can now process films in a very short cycle, saving money while increasing its ability to comply with environmental limits on discharges of silver into drained waters. This paper will also address other means to reduce the silver freight in the wash water. Opportunities but most of all issues involved in the application of these technologies will be highlighted. Thus the presenter of this paper will demonstrate how film radiography responds to environmental concerns without causing extra financial burdens for the user. (author)

  1. Are radiography lecturers, leaders?

    International Nuclear Information System (INIS)

    Hendry, Julie Anne

    2013-01-01

    This review article aims to explore the concept of radiography lecturers acting as leaders to their student followers. Through a brief review of the literature, a definition of leadership is suggested and some leadership theories explored. The path-goal theory, leader–member exchange theory and the contemporary theory of transformational leadership are examined more closely. Links between lecturer-leader behaviour and student motivation and learning are tentatively suggested with transformational leadership appearing to offer the optimal leadership style for lecturers to adopt. The paucity of literature relating directly to radiography is acknowledged and areas for further research are suggested. The article concludes with some of the author's practical ideas for incorporating transformational leadership styles and behaviours into radiography education today

  2. Computed radiography in paediatrics

    International Nuclear Information System (INIS)

    Kelly, C.

    1996-01-01

    Computed radiography has also been called storage phosphor technology, digital luminescence radiography and scintillation phosphor technology, since it relies on phosphor imaging plate as an alternative to screen-film. One of the major advantages in the use of computed radiography (CR) is the consistent image quality independence of the radiographer and exposure used. And secondly a marked reduction in the need for repeat films was achieved and thus a decrease in dose to the patient. In some cases, dose was able to be reduced further due to the fact that the plates respond to lower doses and still provide adequate image quality. Digitalising the Cr image allows it to be transmitted to an imaging console. The images can then be stored on optical disc. 7 refs

  3. 30 CFR 56.4230 - Self-propelled equipment.

    Science.gov (United States)

    2010-07-01

    ....4230 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Equipment § 56.4230 Self-propelled equipment. (a)(1) Whenever a fire or its effects...

  4. A model-based radiography restoration method based on simple scatter-degradation scheme for improving image visibility

    Science.gov (United States)

    Kim, K.; Kang, S.; Cho, H.; Kang, W.; Seo, C.; Park, C.; Lee, D.; Lim, H.; Lee, H.; Kim, G.; Park, S.; Park, J.; Kim, W.; Jeon, D.; Woo, T.; Oh, J.

    2018-02-01

    In conventional planar radiography, image visibility is often limited mainly due to the superimposition of the object structure under investigation and the artifacts caused by scattered x-rays and noise. Several methods, including computed tomography (CT) as a multiplanar imaging modality, air-gap and grid techniques for the reduction of scatters, phase-contrast imaging as another image-contrast modality, etc., have extensively been investigated in attempt to overcome these difficulties. However, those methods typically require higher x-ray doses or special equipment. In this work, as another approach, we propose a new model-based radiography restoration method based on simple scatter-degradation scheme where the intensity of scattered x-rays and the transmission function of a given object are estimated from a single x-ray image to restore the original degraded image. We implemented the proposed algorithm and performed an experiment to demonstrate its viability. Our results indicate that the degradation of image characteristics by scattered x-rays and noise was effectively recovered by using the proposed method, which improves the image visibility in radiography considerably.

  5. Safety of information in electronic equipment influenced by the charged space particles

    Directory of Open Access Journals (Sweden)

    Ksenia Gennad’evna Sizova

    2016-10-01

    Full Text Available A version of the existing evaluation method of electronic equipment to the influence of charged space particles causing single event effects for the purpose of improving the accuracy of calculation in the field of information safety is suggested. On the basis of the existing and modified methods radiation tolerance of real payload spacecraft responsible for the security of transmitted information are defined. The results of comparison are introduced. Significant differences not only in quantitative but also in qualitative character of tolerance indicators are revealed. It is demonstrated that the modified method allows to take into account the functional complexity of the hardware and the application efficiency of the sophisticated single event effects protection tools. To confirm the applicability of the modified method of equipment tolerance evaluation method to the influence of charged space particles causing single event effects proposals to the procedure of ground tests of the payload and the space experiment are developed.

  6. Visualization and measurement of fluid phenomena using neutron radiography techniques

    International Nuclear Information System (INIS)

    Mishima, Kaichiro; Hibiki, Takashi; Fujine, Shigenori; Yoneda, Kenji; Kanda, Keiji; Nishihara, Hideaki; Tsuruno, Akira; Matsubayashi, Masahito; Sobajima, Makoto; Ohtomo, Shoichi.

    1993-01-01

    This paper presents some of the results from recent work performed on the application of neutron radiography to visualization and measurement of fluid phenomena at the Research Reactor Institute of Kyoto University. Experiments have been performed on the following subjects with use of the NR systems at the Japan Research Reactor 3 and the Nuclear Safety Research Reactor of the Japan Atomic Energy Research Institute as well as the Kyoto University Research Reactor: air-water flow in rectangular ducts with 1.0 and 2.4 mm gaps, air-water flow and steam-water flow in a round tube with 4.0 mm inner diameter. The void fraction was measured by processing the images taken by the neutron radiography. The effect of several corrections in image processing was also discussed previously. It was shown that the proposed method could be useful in observing the flow regimes and measuring the void fraction of gas-liquid two-phase flow in narrow channels. (author)

  7. Industrial radiography techniques and their applications

    International Nuclear Information System (INIS)

    Wamorkar, R.R.

    1981-01-01

    Various aspects of industrial radiography are discussed. These include: radiation sources, geometrical unsharpness of image, radiation attenuation in the specimen, radiation effect of film, types of film, intensifying screens, exposure time calculations, source to film distance and sensivitity. Radiography techniques for examination of welded joints on flat plate and pipes or cylindrical objects, and castings are indicated. Applications of radiography in various industries are mentioned. (M.G.B.)

  8. Renewal of radiological equipment.

    Science.gov (United States)

    2014-10-01

    In this century, medical imaging is at the heart of medical practice. Besides providing fast and accurate diagnosis, advances in radiology equipment offer new and previously non-existing options for treatment guidance with quite low morbidity, resulting in the improvement of health outcomes and quality of life for the patients. Although rapid technological development created new medical imaging modalities and methods, the same progress speed resulted in accelerated technical and functional obsolescence of the same medical imaging equipment, consequently creating a need for renewal. Older equipment has a high risk of failures and breakdowns, which might cause delays in diagnosis and treatment of the patient, and safety problems both for the patient and the medical staff. The European Society of Radiology is promoting the use of up-to-date equipment, especially in the context of the EuroSafe Imaging Campaign, as the use of up-to-date equipment will improve quality and safety in medical imaging. Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or renewal. This plan should look forward a minimum of 5 years, with annual updates. Teaching points • Radiological equipment has a definite life cycle span, resulting in unavoidable breakdown and decrease or loss of image quality which renders equipment useless after a certain time period.• Equipment older than 10 years is no longer state-of-the art equipment and replacement is essential. Operating costs of older equipment will be high when compared with new equipment, and sometimes maintenance will be impossible if no spare parts are available.• Older equipment has a high risk of failure and breakdown, causing delays in diagnosis and treatment of the patient and safety problems both for the patient and the medical staff.• Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or replacement. This plan should look forward a

  9. Vertebral Fracture Assessment in Supine Position : Comparison by Using Conventional Semiquantitative Radiography and Visual Radiography

    NARCIS (Netherlands)

    Hospers, Ilone C.; van der Laan, Johan G.; Zeebregts, Clark J.; Nieboer, Patrick; Wolffenbuttel, Bruce H. R.; Dierckx, Rudi A.; Kreeftenberg, Herman G.; Jager, Pieter L.; Slart, Riemer H. J. A.

    Purpose: To retrospectively evaluate the accuracy of vertebral fracture assessment (VFA) performed with the patient in the supine position and conventional semiquantitative radiography of the spine by using conventional visual radiography of the spine as the reference standard. Materials and

  10. Radiography - A new field among health sciences in Finland

    International Nuclear Information System (INIS)

    Pakarinen, Ritva; Jussila, Aino-Liisa

    2007-01-01

    In order to secure high quality X-ray services and efficient operation of clinical radiography, a study programme in radiography science was implemented at the University of Oulu in 1999. The need for a specific field of science has emerged as a result of social changes, such as the aging population, and the fast development of technology that has caused significant changes in the radiological working environment and clinical radiography. A need for a new, research-based informational foundation of clinical radiography is the basis for the programme. As service producers, radiographers need vast knowledge as well as specific expertise. The research object of radiography science is clinical radiography. If it was studied from the viewpoint of other sciences, the key professional skills of a radiographer would remain unexplored. Implementing an own field of science has enabled the development of radiography from its own bases. Basic research in the field is represented, for example, by the concept analysis of radiography in health sciences. Radiography science should produce research results for both clinical radiography and the instruction of radiography. So far, research results have dealt with the professional decision-making of a radiographer, the influences of computer technology on a radiographer's work and measuring the radiation exposure of a population

  11. Survey of radiological safety in dental practice

    Energy Technology Data Exchange (ETDEWEB)

    Gill, J R [UKAEA Health and Safety Branch, London; Hudson, A P

    1977-01-01

    A pilot survey of radiological protection in dental practice in Great Britain has been requested by the Health and Safety Executive and is now in progress. The survey should provide more precise data on the use of X-ray equipment. There are approximately 13,000 dentists in Great Britain using X-ray apparatus, and some 600 of these have been selected, on a statistical basis, to be invited to make use of a postal survey over a six month period. The postal survey technique to be used has already been developed as a service following requests from individual dentists. The dentist receives a questionnaire and three initial films to test the timer, then two special cassettes incorporating film and filters. Film badges are worn over a 12 week period by the dentist and by any staff who assist in radiography. Follow-up visits to discuss the survey will be made to one in ten of the selected dentists. The results will give the individual dentists, without cost, assurance of the efficient functioning of their equipment, and advice, should any remedial measures be necessary. Concurrently, the resulting statistics will give an indication of how many, if any, practices fall short of the recommendations of the Code of Practice for the Protection of Persons against Ionizing Radiations arising from Medical and Dental Use. Further action in respect of the Health and Safety at Work Act will be determined in the light of the survey.

  12. A Neutron Radiography System for Field Use

    Science.gov (United States)

    1989-06-01

    provoked a major renewal of interest in neutron radiography because it promises to bring neutron radiography to the workplace , a convenience provided...II I~F I C II i IiH i ii MTL TR 89-52 I-AD A NEUTRON RADIOGRAPHY SYSTEM N FOR FIELD USE e~m JOHN J. ANTAL and ALFRED S. MAROTTA, and LOUIS J. FARESE...COVERED A NEUTRON RADIOGRAPHY SYSTEM FOR FIELD USE Final Report 6. PERFORMING OR1. REPORT NUMBER 7. AUTHOR(s) S. CONTRACT OR GRANT NUMBER(s) John J

  13. A study on the test of efficiency of the diagnostic X-ray equipment according to their rectifications

    International Nuclear Information System (INIS)

    Seon, Jong Ryul

    1997-01-01

    For the efficient management of the diagnostic x-ray equipment, a nation-wide inspection of hospitals was performed by an inspection institute in Taejon in the first half of 1997. Among those hospitals inspected, 28 equipments(machines) which were over 500 mA were randomly selected according to their characteristics : 7 condenser type x-ray equipments, 7 three control phase of full wave rectification of type remote control x-ray equipments, 7 single phase of full wave rectification type for general radiography equipments, and 7 single phase of full wave rectification type of R/F equipments. We obtained the following results by conducting the experiment based on the efficiency of the equipments mentioned above. 1) When te equipments are analyzed, 2 out of 7 single phase of full wave rectification type of general radiography equipments(28.6%), 3 out of 7 single phase of full wave rectification type of R/F equipments(42.9%), 5 out of 7 three phase of full wave rectification type remote of control x-ray equipments(71.4%), and 4 out of 7 condenser type of x-ray equipments(57.1%) showed suitability. It proves the superiority of the three phase of full wave rectification type of remote control x-ray equipments. 2) From the overall analysis, only about 50% of the equipments(suitability of 14 out of 28) maintain the efficient management. Therefore, maintenance management of equipments is more necessary. If the efficiency of the x-ray equipment is uniformly maintained and managed to prevent the breakdown(trouble) beforehand especially through the continuous inspection of tube voltage, tube current, exposure time, and collimator, the financial loss and exposure dose to the patient, as well as the workers engaged in radiation, can be reduced for better medical service

  14. Patient radiation dose in some dental radiography clinics in Khartoum, Sudan

    International Nuclear Information System (INIS)

    Mohamed, Aziza Hamed Abdelgadir

    2016-01-01

    Patient dose audit is an important tool for quality control and it is important for monitoring patient exposure. The DAP meter has proved to be an easy and accurate tool for patient dosimetry and for establishment of diagnostic reference levels in dental radiology. The objective of this study was measure patient dose in dental radiography in some dental radiography clinics in Khartoum. The study was performed in five dental clinics comprising six panoramic and six intraoral dental radiography devices in Khartoum state. The incident surface air kerma (k i ) and dose area product were measured for intraoral and panoramic dental examinations, respectively for digital and film imaging modalities. Incident surface air kerma (k i ) was measured using calibrated dose rate meter where dose area product were determined from dose width product (DWP) measured using 3 cc pencil type CT ionization chamber. For intraoral examinations, the maximum, average and minimum, (1.95, 1.48, and 1.24) mGy, (5.84, 4.54, and 3.6) mGy for digital and imaging, respectively. This result was lower in digital in traol and higher in film imaging. The result for panoramic examination calculated dose area product (DAP) mean value for adult and pediatric was (103, 70.42) mGy cm 2 , respectively, where the dose for digital imaging was highest in two centers, compared to previous study. Increased patient dose in intraoral dental radiography could partially be explained by the use of circular collimators. or intraoral x-ray equipment the downward trend in patient dose can only be continue, a through the adoption of digital imaging methods. Our results are relatively higher in digital panoramic dental examinations. It is important to point out that non of the dental units under study were covered by regular quality assurance programme.(Author)

  15. Characterization of non-tuberculosis mycobacteria by neutron radiography

    International Nuclear Information System (INIS)

    Silva, Jaqueline M. da; Crispim, Verginia Reis; Gomes da Silva, Marlei; Furtado, Vanessa Rodrigues; Duarte, Rafael Da Silva

    2013-01-01

    The genus Mycobacterium shares many characteristics with Corynebacterium and Actinomyces genera, among which the genomic guanine plus cytosine content and the production of long branched-chain fatty acids, known as mycolic acids are enhanced. Growth rate and optimal temperature of mycobacteria are variable. The genus comprises more than 140 known species; however Mycobacterium fortuitum, a fast growing nontuberculous mycobacterium, is clinically significant, because it has been associated to several lesions following surgery procedures such as liposuction, silicone breast and pacemaker implants, exposure to prosthetic materials besides sporadic lesions in the skin, soft tissues and rarely lungs. The objective of the present study is to reduce the time necessary for M. fortuitum characterization based on its morphology and the use of the neutron radiography technique substituting the classical biochemical assays. We also aim to confirm the utility of dendrimers as boron carriers. The samples were sterilized through conventional protocols using 10% formaldehyde. In the incubation process, two solutions with different molar ratios (10:1 and 20:1) of sodium borate and PAMAM G4 dendrimer and also pure sodium borate were used. After doping and sterilization procedures, the samples were deposited on CR-39 sheets, irradiated with a 4.6×10 5 n/cm 2 s thermal neutron flux for 30 min, from the J-9 irradiation channel of the Argonauta IEN/CNEN reactor. The images registered in the CR-39 were visualized in a Nikon E400 optical transmission microscope and captured by a Nikon Coolpix 995 digital camera. Developing the nuclear tracks registered in the CR-39 allowed a 1000× enlargement of mycobacterium images, facilitating their characterization, the use of more sophisticated equipment not being necessary. The use of neutron radiography technique reduced the time necessary for characterization. Doping with PAMAM dendrimer improved the visualization of NTM in neutron radiography

  16. State of maintenance of JRR-3M neutron radiography facilities

    International Nuclear Information System (INIS)

    Tsuruno, Akira

    1994-01-01

    Nearly two years have elapsed since the use of the JRR-3M neutron radiography facilities was begun. Five years passed since the decision of the detailed specification, and this period is enough for the contained equipment and the peripheral equipment become old-fashioned. In addition, as unexpected high performance was obtained by these facilities, the measures were to be taken in many places. In this fiscal year, the improvement of the contained equipment and the increase of the peripheral equipment were carried out. These improvement and renewal are still insufficient for these facilities demonstrate the performance fully, and are expected to continue hereafter. As the measures taken in relation to the TNRF-2, the renewal of the BN shutter, the remodeling of the black box and the improvement of the interlock were carried out. As the measures taken in relation to CNRF, the new installation of auxiliary shields, the remodeling of the shutter and the new installation of internal illumination were carried out. As the measures taken in relation to the image processor, the outline based on long term perspective is shown. The equipments which were purchased in this fiscal year are the work station which becomes the center of the image-processing network, the cooled CCD camera system and the SIT camera for renewal. In the dark room, a scanning micro-densitometer was installed. (K.I.)

  17. Student perspective on using a virtual radiography simulation

    International Nuclear Information System (INIS)

    Shanahan, Madeleine

    2016-01-01

    Aim: Virtual radiography allows students to practice a range of radiographic techniques in a safe learning environment. The aim of this pilot study was to introduce Projection VR™, a software simulation, into the academic environment and harvest user feedback about the application. Methods: Purposefully designed worksheets were developed to support the implementation of Projection VR™ into the laboratory component of an undergraduate diagnostic radiography course. Following completion of the course, all enrolled students (N = 86) were invited to complete an online survey to ascertain student perceptions on technical issues and educational value of the software. Descriptive and inferential statistics were applied. Results: Responses were received from 84 students (response rate 98%). The student cohort had a range of confidence levels in their computer technology ability, with significant relationships observed for gender (p = 0.025) and age group (p = 0.016). Few students (19) had previously used simulation software. Overall students were positive regarding ease of use (83%) and ability to control the equipment as needed (89%). Primary benefits of using the simulation included allowing students to repeat activities until satisfied with the results (95%) and being able to quickly see images and understand if changes needed to be made (94%). Students reported the simulation positively developed their technical (78%), image evaluation (85%), problem solving (85%) and self-evaluation (88%) abilities. Conclusion: Student feedback indicates that virtual radiography simulation has a valuable role to play developing technical and cognitive skills. Future work will extend the implementation of this software across multiple courses. - Highlights: • With Virtual Radiography™ students produce images without using ionising radiation. • Students can repeat activities until satisfied with the results. • Students can quickly see images and understand if changes

  18. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... the equipment look like? How does the procedure work? How is the procedure ... diagnose and treat medical conditions. Imaging with x-rays involves exposing a part ...

  19. Lonizing radiation regulations and the dental practitioner: 3. Quality assurance in dental radiography.

    Science.gov (United States)

    Rout, John; Brown, Jackie

    2012-06-01

    This is the last in a series of three articles on X-ray dose reduction and covers aspects of quality assurance. The first outlined radiation physics and protection and the second the legislation relating to radiation safety. Quality assurance is an essential part of dental radiography and is required to produce images of a consistently high standard, necessary for accurate diagnosis.

  20. Manual on gamma radiography. Incorporating: Applications guide, procedures guide, basics guide

    International Nuclear Information System (INIS)

    1996-01-01

    This publication is part of practical radiation safety manual series for different fields of application aimed primarily at persons handling radiation sources on a daily routine basis, which could at same time be used by the competent authorities, supporting their efforts in the radiation protection training of workers or medical assistance personnel or helping on-site management to set up local radiation protection rules. It is dedicated to gamma radiography: its application and procedures guides

  1. Broadening the radiography spectrum

    International Nuclear Information System (INIS)

    Waswa, L.; Mutwasi, O.; Kioko, J.

    2006-05-01

    The text discuses the mammography in breast screening and evaluation of breast cancer; Small parts ultrasounds at plaza imaging solutions; role of a Radiographer in mammography-new perspective; Medical imaging education in africa; Caring for the paediatric patient as to broaden radiotherapy spectrum; Problems and challenges in care for children undergoing radiotherapy; Paediatric radiotherapy, management and side effects; The principles of pattern recognition of skeletal structures; the place of distance learning education in broadening the radiography spectrum; the curriculum and budgeting image; sonographer's guide; Computed radiography- X-Ray with vision; digital Radiography in Kenya today; Particle Therapy at Ithemba Labs; The role of lung perfusion and ventilation study in the evaluation of the pulmonary embolism and lastly, an overview of Head and neck treatment at Kenyatta National hospital radiotherapy

  2. Practical approaches to implementing facility wide equipment strengthening programs

    International Nuclear Information System (INIS)

    Kincaid, R.H.; Smietana, E.A.

    1989-01-01

    Equipment strengthening programs typically focus on components required to ensure operability of safety related equipment or to prevent the release of toxic substances. Survival of non-safety related equipment may also be crucial to ensure rapid recovery and minimize business interruption losses. Implementing a strengthening program for non-safety related equipment can be difficult due to the large amounts of equipment involved and limited budget availability. EQE has successfully implemented comprehensive equipment strengthening programs for a number of California corporations. Many of the lessons learned from these projects are applicable to DOE facilities. These include techniques for prioritizing equipment and three general methodologies for anchoring equipment. Pros and cons of each anchorage approach are presented along with typical equipment strengthening costs

  3. Equipment design guidance document for flammable gas waste storage tank new equipment

    International Nuclear Information System (INIS)

    Smet, D.B.

    1996-01-01

    This document is intended to be used as guidance for design engineers who are involved in design of new equipment slated for use in Flammable Gas Waste Storage Tanks. The purpose of this document is to provide design guidance for all new equipment intended for application into those Hanford storage tanks in which flammable gas controls are required to be addressed as part of the equipment design. These design criteria are to be used as guidance. The design of each specific piece of new equipment shall be required, as a minimum to be reviewed by qualified Unreviewed Safety Question evaluators as an integral part of the final design approval. Further Safety Assessment may be also needed. This guidance is intended to be used in conjunction with the Operating Specifications Documents (OSDs) established for defining work controls in the waste storage tanks. The criteria set forth should be reviewed for applicability if the equipment will be required to operate in locations containing unacceptable concentrations of flammable gas

  4. INDIVIDUAL AND ORGANIZATIONAL VARIABLES AFFECTING THE USE OF PERSONAL PROTECTIVE EQUIPMENT

    Directory of Open Access Journals (Sweden)

    TUNÇ DEMİRBİLEK

    2013-06-01

    Full Text Available Management’s safety approach and commitment are related to occupational health and safety applications in workplaces. However, personal characteristics and attitudes on their health of employees are very influential factors on occupational health and safety applications. For examine of interaction between behaviors and the health and safety applications it is required that determine of employee’s perceptions. For this reason this paper’s purpose is to establish of safety needs, attitudes and behaviors of employees and their perceptions regarding management’s safety approach and applications. The study’s focal point is use of personal protective equipment as an indicator “safety behavior”. In empirical study, assumption variables regarding the use of personal protective equipment are safety effectively, safety need, management attitudes and protective equipment conditions. The fundamental hypothesis of this paper is use of personal protective equipment is related to individual and organizational variables. Implications of research findings are to indicate impelling the workers to safety behaviour or using the personal protective equipment by their feeling of the safety behaviour and availability of personal protective equipment.

  5. The evaluation the magnitude radiation exposure dose rate in digital radiography room design

    Science.gov (United States)

    Dwiyanto, Agung; Setia Budi, Wahyu; Hardiman, Gagoek

    2017-12-01

    This study discusses the dose rate in digital radiography room, buit according to meet the provisions of KEMENKES No.1014 / Menkes / SK / XI / 2008 and Regulation of BAPETEN No. 8 / 2011. The provisions primary concern of radiation safety, not comfort, by considering the space design. There are five aspects to consider in designing the space: functionality, comfort, security, movement activities and aesthetics. However provisions only met three aspects of the design, which are a function, security and movement activity. Therefore, it is necessary to evaluate digital radiography room in terms of its ability to control external radiation exposure to be safe and comfortable The dose rate is measured by the range of primary and secondary radiation in the observation points by using Surveymeter. All data are obtained by the preliminary survey prior to the study. Furthermore, the review of digital radiography room is done based on architectural design theory. The dose rate for recommended improvement room is recalculated using the same method as the actual room with the help of computer modeling. The result of dose rate calculation at the inner and outer part of digital radiography observation room shows that in-room dose for a week at each measuring point exceeds the allowable dose limit both for staff and public. During a week of observation, the outdoor dose at some measuring points exceeds the dose limit set by the KEMENKES No.1014 / Menkes / SK / XI / 2008 and Regulation BEPETEN No 8/2011. Meanwhile, the result of dose rate calculation in the inner and outer part of the improved digital radiography room can meet the applicable regulations better.

  6. Contributions to the research programs in nuclear and industrial electronics, domestic production of instrumentation, safety and control systems and equipment for nuclear reactors and auxiliary installations

    International Nuclear Information System (INIS)

    Talpariu, C; Talpariu, J.; Matei, C.

    2001-01-01

    Domestic production of component system and equipment for the control and safety of nuclear facilities was one of the priority objective of the Nuclear Research Institute Pitesti. The problems addressed were particularly related to design and production of analog and digital equipment for measurements, triggering and display of the values of process parameters as well as to regulating complex functions of this equipment. Associated to this effort were the research works concerning: - reliability and in-service life-time of the electronic components and equipment in the safety and control systems for nuclear processes; - radiation endurance of industrial electronic components; utilization of whirling currents in calandria tube testing; - expert systems and applications in nuclear reactor control and safety; design and testing methods of process real time software packages for safety in control critical systems for nuclear domain. There are presented characteristics of the following equipment: 1. amplifier for ionization chambers with triggering comparator circuits for the CANDU 600 reactor shut down system; 2. amplifier for ionization chambers without triggering comparator circuits for power regulating system; 3. safety and regulating computerized system for C9 and C5 cans; 4. acquisition system for dosimetric data in nuclear facilities; 5. program able digital comparator for the reactor shut down system; 6. stationary gamma areal monitors for CANDU 600 reactors and other nuclear facilities

  7. High energy neutron radiography

    International Nuclear Information System (INIS)

    Gavron, A.; Morley, K.; Morris, C.; Seestrom, S.; Ullmann, J.; Yates, G.; Zumbro, J.

    1996-01-01

    High-energy spallation neutron sources are now being considered in the US and elsewhere as a replacement for neutron beams produced by reactors. High-energy and high intensity neutron beams, produced by unmoderated spallation sources, open potential new vistas of neutron radiography. The authors discuss the basic advantages and disadvantages of high-energy neutron radiography, and consider some experimental results obtained at the Weapons Neutron Research (WNR) facility at Los Alamos

  8. WE-G-209-01: Digital Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Schueler, B. [Mayo Clinic (United States)

    2016-06-15

    Digital radiography, CT, PET, and MR are complicated imaging modalities which are composed of many hardware and software components. These components work together in a highly coordinated chain of events with the intent to produce high quality images. Acquisition, processing and reconstruction of data must occur in a precise way for optimum image quality to be achieved. Any error or unexpected event in the entire process can produce unwanted pixel intensities in the final images which may contribute to visible image artifacts. The diagnostic imaging physicist is uniquely qualified to investigate and contribute to resolution of image artifacts. This course will teach the participant to identify common artifacts found clinically in digital radiography, CT, PET, and MR, to determine the causes of artifacts, and to make recommendations for how to resolve artifacts. Learning Objectives: Identify common artifacts found clinically in digital radiography, CT, PET and MR. Determine causes of various clinical artifacts from digital radiography, CT, PET and MR. Describe how to resolve various clinical artifacts from digital radiography, CT, PET and MR.

  9. Neutron radiography at the HFR Petten compilation of HFR Petten contributions to the second world conference on neutron radiography

    International Nuclear Information System (INIS)

    Markgraf, J.W.F.

    1986-01-01

    This booklet summarizes the six papers on neutron radiography activities at the Petten High Flux Reactor (HFR), presented at the Second World Conference on neutron radiography, held in June 1986 in Paris, France. The conference was organized by the French CEA and COFREND, and JRC Petten, HFR Division, with joint sponsorship of the national societies on Non-Destructive Testing (NDT) from the Federal Republic of Germany, United Kingdom, Japan and the United States. The Petten papers are concerned with: (i) the work of the Neutron Radiography Working Group (NRWG), an expert group operating under the auspices of the Commission of the European Communities represented by JRC Petten, HFR Division; (ii) applications of neutron radiography in research programmes performed at HFR; (iii) neutron radiography facilities at HFR; and (iv) image evaluation techniques

  10. Imaging of bone tumors: evaluation of direct magnification radiography

    International Nuclear Information System (INIS)

    Link, T.M.; Hillmann, A.; Erlemann, R.; Groenefeld, A.; Haeussler, M.; Heppe, A.E.; Vestring, T.; Peters, P.E.

    1996-01-01

    Objective. To evaluate the potentials of magnification radiography as compared with conventional radiography in diagnosing bone tumors. Design and patients. Sixty-two patients with primary bone tumors and tumorlike lesions underwent radiography with both conventional (non-magnified) and magnification (fivefold) techniques. All radiographs were analyzed by four radiologists and the findings correlated with the histopathology findings. The microfocal X-ray unit used for magnification radiography had a focal spot size of 20-130 μm. Digital luminescence radiography was employed with magnification, while normal film-screen systems were used with conventional radiography. Results. The diagnosis of benign and malignant lesions as well as the individual tumor diagnosis were determined with higher accuracy using magnification compared with conventional radiography (88% vs 75% and 71% vs 52%, p<0.01). Margins of destruction, periosteal reactions and matrix patterns were evaluated with higher certainty by all of the radiologists (p<0.01). Conclusion. Magnification radiography may improve the evaluation and diagnosis of bone tumors. (orig.). With 6 tabs

  11. Industrial Radiography | Radiation Protection | US EPA

    Science.gov (United States)

    2017-08-07

    Manufacturers use a method called industrial radiography to check for cracks or flaws in materials. Radiation is used in industrial radiography to show problems not visible from the outside without damaging the material.

  12. The advantages of digital radiography in department of radiology

    International Nuclear Information System (INIS)

    Mao Lijuan; Luo Xiaomei; Wu Tengfang

    2009-01-01

    Objective: To investigate the advantages of digital radiography in department of radiology by comparing digital radiography with common radiography. Methods: Test card was used for testing the spatial resolution of DR and common radiography. 1000 films of chest by DR and 1000 films of chest by common radiography were compared in image quality, dose of radiation, the rate of waste film, and the advantages of DR was analyzed. Results: Compared to common radiography, DR had a high sensitivity, high DQE (quantum detection efficiency), high spatial resolution and density resolution. The speed of acquisition and X-ray conversion efficiency were fast. The function of post-processing was strong and the rate of disease detection was high. Conclusion: DR is better than common radiography in all respects, it will be widely applied. (authors)

  13. Chest radiography after minor chest trauma

    Energy Technology Data Exchange (ETDEWEB)

    Rossen, B.; Laursen, N.O.; Just, S.

    The results of chest radiography in 581 patients with blunt minor thoracic trauma were reviewed. Frontal and lateral views of the chest indicated pathology in 72 patients (12.4%). Pneumothorax was present in 16 patients; 4 had hemothorax. The physical examination and the results of chest radiography were not in accordance because in 6(30%) of the 20 patients with hemo/-pneumothorax the physical examination was normal. Consequently there is wide indication for chest radiography after minor blunt chest trauma.

  14. Chest radiography after minor chest trauma

    International Nuclear Information System (INIS)

    Rossen, B.; Laursen, N.O.; Just, S.

    1987-01-01

    The results of chest radiography in 581 patients with blunt minor thoracic trauma were reviewed. Frontal and lateral views of the chest indicated pathology in 72 patients (12.4%). Pneumothorax was present in 16 patients; 4 had hemothorax. The physical examination and the results of chest radiography were not in accordance because in 6(30%) of the 20 patients with hemo/-pneumothorax the physical examination was normal. Consequently there is wide indication for chest radiography after minor blunt chest trauma. (orig.)

  15. Representability of metastatic bone lesions in magnification radiography

    International Nuclear Information System (INIS)

    Togawa, Takashi

    1981-01-01

    Magnification radiography, bone scintigraphy, and normal roentgenography were performed on patients with malignant tumors to detect their bone metastases, and from the results obtained, these diagnostic procedures were evaluated for the detectability and representability of metastatic bone lesions. Bone scan and normal roentgenography were performed on 90 metastatic bone lesions in 37 patients, and magnification radiography was done on 14 bone lesions noted in 10 of the 37 and another with benign osseous change. Among the three, bone scintigraphy was best, and magnification radiography and normal roentgenography did not differ significantly in detectability. In magnification radiography, some metastatic bone lesions were represented more clearly than by normal roentgeography, but some were not. As regards the representability of the ribs, magnification radiography was very useful. One case of bone destruction was detected by magnification radiography, but not by normal roentgenography. (author)

  16. Process waste assessment for the Radiography Laboratory

    International Nuclear Information System (INIS)

    Phillips, N.M.

    1994-07-01

    This Process Waste Assessment was conducted to evaluate the Radiography Laboratory, located in Building 923. It documents the processes, identifies the hazardous chemical waste streams generated by these processes, recommends possible ways to minimize waste, and serves as a reference for future assessments of this facility. The Radiography Laboratory provides film radiography or radioscopy (electronic imaging) of weapon and nonweapon components. The Radiography Laboratory has six x-ray machines and one gamma ray source. It also has several other sealed beta- and gamma-ray isotope sources of low microcurie (μCi) activity. The photochemical processes generate most of the Radiography Laboratory's routinely generated hazardous waste, and most of that is generated by the DuPont film processor. Because the DuPont film processor generates the most photochemical waste, it was selected for an estimated material balance

  17. Portable digital electronic radiography system

    International Nuclear Information System (INIS)

    Sawicka, B.D.

    1995-01-01

    Radiography is a standard nondestructive technique in the industrial testing of materials and components. It is routinely used during the construction, maintenance and repair of nuclear plants. Traditionally, radiography is performed using photographic film (film radiography, FR). Recent developments in solid-state area imaging radiation detectors, miniature electronics and computer software/hardware techniques have brought electronic alternatives to FR. In recent years various electronic radiography (ER) techniques have served as alternatives to FR, these proved beneficial in some applications. While originally developed to provide real time imaging, ER may offer other advantages over FR, depending on the application. Work was undertaken at CRL to review progress in ER techniques and evaluate the possibility of constructing a portable DER (digital electronic radiography) system, for the inspection of power plant components. A suitable DER technique has been developed and a proof of principle portable system constructed. As this paper demonstrates, a properly designed ER system can be small and compact, while providing radiographic examination with acceptable image quality and the benefits of ER imaging. The CRL DER system can operate with radioactive sources typical of FR. While it does not replace FR, our DER system is expected to be beneficial in specific applications for Candu maintenance, reducing cost, labour and time. Practical, cost saving applications of this system are expected to include valve monitoring and foreign object location during maintenance at Candu reactors

  18. Computed radiography for breast cancer

    International Nuclear Information System (INIS)

    Yamada, Tatsuya; Muramatsu, Yukio

    1990-01-01

    In order to evaluate the possibility of using computed radiographic mammography in mass surveys of the breast, we have retrospectively examined 71 breast cancer lesions in 71 patients using computed radiographic and conventional non-screen mammographies and have carried out comparative studies on tumor detection rate and calcification. A 95.8% detection rate was obtained for the tumor image (n 71) using computed radiography (CR) and one of 93.0% using non-screen techniques. Three lesions remained undetected by either study. A 100% detection rate was obtained for calcification associated with cancer (n 33) from each method. No significant differences in either detection rate or calcification were seen between the two images. On the other hand, the ability to recognize tumor images (n 66) was as follows; CR superior to non-screen radiography in 53 lesions (80.3%), equal in eight lesions (12.1%) and inferior in five lesions (7.6%). For the calcification images (n 18), CR was superior to non-screen radiography in all 18 lesions. Obviously, CR gives better results than non-screen radiography. Furthermore, an adequate image can be obtained using CR even although the X-ray dosage is only a twentieth of that required for non-screen radiography. It can therefore be applied not only to mass surveys for breast cancer but also to routine clinical diagnoses. (author)

  19. Reference dose levels for dental panoramic radiography in Anyang City

    International Nuclear Information System (INIS)

    Han, Mi Ra; Kang, Byung Cheol; Yoon, Suk Ja; Lee, Jae Seo; Kim, Young Hee

    2009-01-01

    To measure dose-width product (DWP) values used for dental panoramic radiography in Anyang city, Korea. Thirty-six panoramic dental radiographic sets (17 analogue panoramic sets and 19 digital panoramic sets) in 36 dental clinics in Anyang city were included in the study. Each patient's panoramic exposure parameters were simulated and the panoramic radiation doses were measured at the secondary collimator using a Mult-O-Meter (Unfors Instruments, Billdal, Sweden) at each dental clinic during 2006. The third quartile DWP was determined from 310 surface dose measurements on adult. The third quartile DWP for adult panoramic radiograph was 106.7 mGy mm. For analogue and digital panoramic radiograph, 3/4 DWP were 116.8 mGy mm and 72 mGy mm respectively. The overall third quartile DWP of panoramic radiography was 106.7 mGy mm. The measured 3/4 DWPs were higher than the 3/4 DWP of 65 mGy mm recommended by NRPB. Dentists who are operating above the reference dose should lower their panoramic exposure doses below the recommended reference value by changing the exposure parameters and/or their panoramic equipment.

  20. Spatially coded backscatter radiography

    International Nuclear Information System (INIS)

    Thangavelu, S.; Hussein, E.M.A.

    2007-01-01

    Conventional radiography requires access to two opposite sides of an object, which makes it unsuitable for the inspection of extended and/or thick structures (airframes, bridges, floors etc.). Backscatter imaging can overcome this problem, but the indications obtained are difficult to interpret. This paper applies the coded aperture technique to gamma-ray backscatter-radiography in order to enhance the detectability of flaws. This spatial coding method involves the positioning of a mask with closed and open holes to selectively permit or block the passage of radiation. The obtained coded-aperture indications are then mathematically decoded to detect the presence of anomalies. Indications obtained from Monte Carlo calculations were utilized in this work to simulate radiation scattering measurements. These simulated measurements were used to investigate the applicability of this technique to the detection of flaws by backscatter radiography

  1. Radiography of pressure ulcers

    International Nuclear Information System (INIS)

    Borgstroem, P.S.; Ekberg, O.; Lasson, A.

    1988-01-01

    In patients with longstanding and/or deep pressure ulcers radiology is usually consulted. Survey radiography and sinography in 14 patients with pressure ulcers (6 over the tuber ischii and 8 over the femoral trochanter) were evaluated. Osteomyelitic involvement of adjacent bone was revealed in 9 patients on survey radiography. However, it was usually impossible to assess whether or not bony involvement represents healed or active osteomyelitis. Sinography did not contribute to the assessment of whether or not adjacent cortical bone was involved. However, when a fistulation to an adjacent joint was revealed this contributed substantially to the preoperative planning of resection. We therefore recommend that survey radiography and sinography should be included in the evaluation of these patients but that the results from such examinations are critically evaluated. Joint involvement should be taken seriously as progression of septic arthritis usually occurs rapidly. (orig.)

  2. Nuclear safety: a large scale quality audit of pressurized equipment

    International Nuclear Information System (INIS)

    Faudon, Valerie

    2016-01-01

    This article notably refers to, quotes and comments a hearing organised by the French Public Office for the Assessment Scientific and Technological Choices (OPECST) on the issue of safety of pressurized equipment in nuclear reactors, and which gathered the main concerned actors (Areva, EDF, IRSN, ASN) to have an overview of quality controls in AREVA NP fabrication plants. Two different issues have been addressed: a technical metallurgical issue related to some boiler-making parts, and an issue related to quality assurance. These issues concern different older reactors (Fessenheim for example) as well as new ones (EPR Flamanville). The article indicates the different measures planned, envisaged or already implemented by the concerned actors in order to improve knowledge in the boiler-making industry, and to ensure a better quality

  3. New development of neutron radiography with a small cyclotron

    International Nuclear Information System (INIS)

    Ikeda, Yasushi; Ohkubo, Kohei; Kato, Toshihiko; Nakamura, Tomihisa; Fuji, Takayoshi.

    1990-01-01

    A series of neutron radiography testing has been performed for several years by using a small accelerator called 'Baby Cyclotron' manufactured by Japan Steel Works, Ltd. The Baby Cyclotron produces fast neutrons at the rate of 4x10 12 n/cm 2 s, and enables to perform neutron radiography imaging by various techniques. The most important application of this Baby Cyclotron radiography system is the non-destructive testing (NDT) of various explosive devices prepared for space launch vehicles. It is assured that thermal neutron radiography testing is a very useful means for the NDT. Also fast neutron radiography testing is in progress. The fast neutron radiography with a CR39 track-etch image recorder was developed, and it was shown to be the very useful NDT means when the thicker objects used for new H-2 launch vehicles had to be examined. Because thermal neutron radiography has the high detectability of hydrogenous materials, organic elastomers such as O-rings and explosive powder are clearly observable through the opaque steel walls of containers. The Baby Cyclotron and the neutron radiography facility, thermal neutron and fast neutron radiography testings and so on are reported. (K.I.)

  4. Examination of welds by digital radiography

    International Nuclear Information System (INIS)

    Ekinci, S.

    2004-01-01

    Industrial radiography is the oldest and most reliable non-destructive test method in the examination and two dimensional evaluation of weld defects. Digital radiographic methods provide more sensitive, faster and more reliable evaluation of defect images. One of the most important factors influencing the contrast and consequently the image quality is the noise on the film caused by scattered radiation. The digital image processing technique can eliminate the noise and improve the image quality. Digital radiography also enables three dimensional evaluation of weld defects. This work describes the use of digital radiography in the evaluation of defects in welds of different configurations by using a laser film digitizing system and an appropriate software programme. Advantages and limitations of the digital technique and conventional film radiography were discussed. (author)

  5. Examination of welds by digital radiography

    International Nuclear Information System (INIS)

    Ekinci, S.

    2004-01-01

    Full text: Industrial radiography is the oldest and most reliable non-destructive test method in the examination and two dimensional evaluation of weld defects. Digital radiographic methods provide more sensitive, faster and more reliable evaluation of defect images. One of the most important factors influencing the contrast and consequently the image quality is the noise on the film caused by scattered radiation. The digital image processing technique can eliminate the noise and improve the image quality. Digital radiography also enables three dimensional evaluation of weld defects. This work describes the use of digital radiography in the evaluation of defects in welds of different configurations by using a laser film digitizing system and an appropriate software programme. Advantages and limitations of the digital technique and conventional film radiography were discussed

  6. Equipment qualification testing - a practical approach

    International Nuclear Information System (INIS)

    Davies, G.A.; McDougall, R.I.; Poirier, M.P.

    1996-01-01

    When nuclear safety equipment is credited with a Required Safety Function it must properly perform that function to facilitate safe control and/or shutdown of the plant during a design basis accident. When such equipment is required to be environmentally (EQ) and/or seismically qualified (SQ) for safety related use in CANDU nuclear power plants, the preferred method of qualification is by type testing. The qualification testing process requires that the test specimen equipment be subjected to the aging stressors associated with the normal service conditions that it would experience during it's required qualified (or service) life. Following the aging process, the test specimen is in a condition representative of that in which it would be at the end of its service life in the plant. The test specimen is then subjected to a simulated accident during which it must satisfy performance requirements thereby demonstrating that it can perform its required safety function. The performance requirements specified for the qualification testing must be designed to ensure that satisfactory performance of the safety function is demonstrated during the qualification program. This paper provides descriptions of practical methods used in the deriving and satisfying of relevant performance requirements during the qualification testing of safety related equipment. (author)

  7. Chest radiography: new technological developments and their applications

    NARCIS (Netherlands)

    Schalekamp, S.; Ginneken, B. van; Karssemeijer, N.; Schaefer-Prokop, C.M.

    2014-01-01

    Digital chest radiography is still the most common radiological examination. With the upcoming three-dimensional (3D) acquisition techniques the value of radiography seems to diminish. But because radiography is inexpensive, readily available, and requires very little dose, it is still being used

  8. Digital and analogue industrial radiography, application fields

    International Nuclear Information System (INIS)

    Willems, Peter; Millord, Erik Yardin

    2000-01-01

    Full text: Reusable phosphor screens for computer radiography (CR), amorphous selenium screens for direct radiography (DR), film digitalisation (FD) constitute imaging methods accepted by industry and are used for non-destructive radiographic testing (RT). Economic pressures are involving and affecting digital RT technology. Standards and codes for film radiography and radioscopy qualification do no longer cover the wide range of digital RT applications. It will be our task to optimise the performance of digital RT characterisation and to create appropriate examination methods to use all these new and existent technologies. In the meantime, an increasing automation and control of manual methods of analogue radiography can as well be expected. (author)

  9. Proceeding of 6th short conference on neutron radiography

    International Nuclear Information System (INIS)

    Katsurayama, Kohsuke; Hiraoka, Eiichi; Tsujimoto, Tadashi

    1984-01-01

    The 6th short conference on neutron radiography was held on August 30 and 31, 1983, at the Research Reactor Institute, Kyoto niversity, as a part of the joint research program of the Institute. During the period since the first meeting in November, 1970, steady development was made in both research and practical use of neutron radiography in Japan owing to the persistent effort of the persons concerned. In the conference, 70 persons participated, and 21 papers were presented. The problems treated were the apparatuses of neutron television, neutron radiography and neutron photography, the various application of neutron radiography, the standard of neutron radiography and others. The high value of neutron radiography and the increasing demand to use this technique were shown in this meeting. Considering the recent rapid development of new technology, it is expected that neutron radiography will find the wide varieties of application in the near future. The proceedings of the conference are published by collecting the gists of papers, hoping to enhance joint effort and the exchange of information to develop neutron radiography. (Kako, I.)

  10. 42 CFR Appendix B to Part 75 - Standards for Accreditation of Dental Radiography Training for Dental Hygienists

    Science.gov (United States)

    2010-10-01

    ... must include content in seven areas: radiation physics; radiation biology; radiation health, safety... 42 Public Health 1 2010-10-01 2010-10-01 false Standards for Accreditation of Dental Radiography Training for Dental Hygienists B Appendix B to Part 75 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF...

  11. Neutron radiography of fuel pins

    International Nuclear Information System (INIS)

    Jackson, C.N. Jr.; Powers, H.G.; Burgess, C.A.

    1975-01-01

    Neutron radiography performed with a reactor source has been shown to be a superior radiographic method for the examination of unirradiated mixed oxide fuel pins at the Hanford Engineering Development Laboratory. Approximately 1,700 fuel pins were contained in a sample that demonstrated the capability of the method for detecting laminations, structural flaws, fissile density variation, hydrogenous inclusions and voids in assembled fuel pins. The nature, extent, and importance of the detected conditions are substantiated by gamma autoradiography and by destructive analysis employing alpha autoradiography, electron microprobe and visual inspection. Also, a series of radiographs illustrate the response of neutron radiography as compared to low voltage and high voltage x-ray and gamma source Iridium 192 radiography. (U.S.)

  12. Neutron radiography with the cyclotron, 3

    International Nuclear Information System (INIS)

    Hiraoka, Eiichi; Fujishiro, Masatoshi; Tsujii, Yukio

    1985-01-01

    Neutron radiography is well recognized as a powerful tool in nondestructive testing, but not widely used yet owing to lack of high intense thermal neutron source convenient for practical use. A new neutron radiograph facility, utilizing a sub-compact cyclotron as neutron source and equipped with vertical and horizontal irradiation ports, is presented in this article. A series of experiment, prior to its construction, was conducted using beams of a variable energy cyclotron at Tohoku University to investigate the characteristics of thermal neutron obtained, from 9 Be (p, n) reaction and thermalized by elastic scattering process. This article describes a computer simulation of neutron moderator to analyze conditions getting maximal thermal neutron flux. Some of practical neutron radiograph examination of aero-space components and museum art objects of classic bronze mirror are also presented together with an attempt realizing real time imaging technique. (author)

  13. Screening of external hazards for NPP with bank type reactor. Modeling of safety related systems and equipment for RBMK. Probabilistic assessment of NPP safety on aircraft impact. Progress report

    International Nuclear Information System (INIS)

    Kostarev, V.

    1999-01-01

    This progress report was produced within the frame of IAEA research project on screening the hazards for NPP with bank type reactor. It covers the following tasks; development of the model for the primary loop system of RBMK; developing the models for safety related equipment of RBMK; developing of models for safety related models of EGP-6 type reactor (Bilibinskaya Nuclear Co-generated heat and Power Plant); and probabilistic assessment of NPP safety on aircraft impact

  14. IEEE Std 600: IEEE trial-use standard requirements for organizations that conduct qualification testing of safety systems equipment for use in nuclear power generating stations

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    The purpose of this standard is to provide requirements for establishing a program for conducting qualification tests of safety systems equipment used in nuclear power generating stations. Compliance with the requirements of this standard does not assure the adequacy of the qualification tests performed. This standard applies to organizations that conduct qualification tests on equipment that has a definable safety function and is an identifiable part of a safety system for use in nuclear power generating stations. It requires a technical program, a quality assurance program, and a demonstrated ability to meet specified technical requirements. It does not apply to materials tests, production tests, normal performance testing, qualification by analysis, qualification by operating experience, or reliability tests such as diesel-generator multiple start tests. The intent of this standard is to achieve greater consistency, reliability, and reproducibility of test results and to provide adequate control of qualification testing of safety systems equipment

  15. State and prospects of industrial neutron radiography in Germany

    International Nuclear Information System (INIS)

    Heidt, H.; Stade, J.

    1988-01-01

    Although the first neutron radiographies in Germany were made nearly 50 years ago, by Kallmann and Kuhn, this nondestructive testing method has not yet been widely used in industry. The main reason is the lack of mobile, intensive and low-cost neutron sources. Another important aspect is the availability of real-time inspection systems equipped with neutron image amplifiers which will accelerate the test and permit to represent dynamic processes. New applications for mobile neutron sources may be expected in aircraft inspection, in testing fibre-reinforced plastics, in different types of ceramic materials, in the building sector, in corrosion protection as well as with various problems encountered with lubrication agents. (orig.) [de

  16. Mass chest radiography in Greece

    International Nuclear Information System (INIS)

    Papavasiliou, C.

    1987-01-01

    In Greece mass chest radiography has been performed regularly on various population groups as a measure to control tuberculosis. Routine chest radiography is performed in most Greek hospitals on admission. In this report available data-admittedly inadequate-directly or indirectly addressing the problem of benefit versus the risk or cost associated with this examination is presented

  17. Multi-Institutional Evaluation of Digital Tomosynthesis, Dual-Energy Radiography, and Conventional Chest Radiography for the Detection and Management of Pulmonary Nodules.

    Science.gov (United States)

    Dobbins, James T; McAdams, H Page; Sabol, John M; Chakraborty, Dev P; Kazerooni, Ella A; Reddy, Gautham P; Vikgren, Jenny; Båth, Magnus

    2017-01-01

    Purpose To conduct a multi-institutional, multireader study to compare the performance of digital tomosynthesis, dual-energy (DE) imaging, and conventional chest radiography for pulmonary nodule detection and management. Materials and Methods In this binational, institutional review board-approved, HIPAA-compliant prospective study, 158 subjects (43 subjects with normal findings) were enrolled at four institutions. Informed consent was obtained prior to enrollment. Subjects underwent chest computed tomography (CT) and imaging with conventional chest radiography (posteroanterior and lateral), DE imaging, and tomosynthesis with a flat-panel imaging device. Three experienced thoracic radiologists identified true locations of nodules (n = 516, 3-20-mm diameters) with CT and recommended case management by using Fleischner Society guidelines. Five other radiologists marked nodules and indicated case management by using images from conventional chest radiography, conventional chest radiography plus DE imaging, tomosynthesis, and tomosynthesis plus DE imaging. Sensitivity, specificity, and overall accuracy were measured by using the free-response receiver operating characteristic method and the receiver operating characteristic method for nodule detection and case management, respectively. Results were further analyzed according to nodule diameter categories (3-4 mm, >4 mm to 6 mm, >6 mm to 8 mm, and >8 mm to 20 mm). Results Maximum lesion localization fraction was higher for tomosynthesis than for conventional chest radiography in all nodule size categories (3.55-fold for all nodules, P chest radiography for all nodules (1.49-fold, P chest radiography, as given by the area under the receiver operating characteristic curve (1.23-fold, P chest radiography or tomosynthesis. Conclusion Tomosynthesis outperformed conventional chest radiography for lung nodule detection and determination of case management; DE imaging did not show significant differences over conventional chest

  18. Standardization activities of the Euratom Neutron Radiography Working Group

    International Nuclear Information System (INIS)

    Domanus, J.

    1982-06-01

    In 1979 a working group on neutron radiography was formed at Euratom. The purpose of this group is the standardization of neutron radiographic methods in the field of nuclear fuel. Activities of this Neutron Radiography Working Group are revised. Classification of defects revealed by neutron radiography is illustrated in a special atlas. Beam purity and sensitivity indicators are tested together with a special calibration fuel pin. All the Euratom neutron radiography centers will perform comparative neutron radiography with those items. The measuring results obtained, using various measuring aparatus will form the basis to formulate conclusions about the best measuring methods and instruments to be used in that field. Besides the atlas of neutron radiographic findings in light water reactor fuel, the Euratom Neutron Radiogrphy Working Group has published a neutron radiography handbook in which the neutron radiography installations in the European Community are also described. (author)

  19. Preliminary safety equipment list for Tank 241-C-106 Manipulator Retrieval System, Project W-340

    International Nuclear Information System (INIS)

    Guthrie, R.L.

    1994-01-01

    This document identifies the anticipated safety classification of the estimated major subsystems, based on the projected major functions, that will be used as guidance for the development of the conceptual design of the Manipulator Retrieval System for Tank 241-C-106. This document is intended to be updated as the design of the Manipulator Retrieval System evolves through the conceptual and definitive design phases. The Manipulator Retrieval System is to be capable of removing the hardened sludge heel at the bottom of single shell Tank 241-C-106 and to perform an overall clean out of the tank that leaves a maximum of 360 ft 3 (TPA milestone M-45-00). The thickness of the heel prior to initiation of waste retrieval with the Manipulator Retrieval System is estimated to be 1- to 2-ft. The Manipulator Retrieval System is currently in the pre-conceptual phase with no definitive systems or subsystems. The anticipated retrieval functions for the Manipulator Retrieval System is based on Table 6-2 of WHC-SD-W340-ES-001, Rev. 1. Projected equipment to accomplish these functions were based on the following systems and equipment: Rotary Mode Core Sampling Equipment (WHC-SD-WM-SEL-032); Light Duty Utility Arm System Equipment (WHC-SD-WM-SEL-034); Single Shell Tanks Equipment (WHC-SD-WM-SEL-020)

  20. The real-time neutron radiography system at Texas A and M University

    International Nuclear Information System (INIS)

    Reuscher, Jon A.

    1990-01-01

    This paper reports on the development and fabrication of a real-time system at Texas A and M University using commercially available and relatively inexpensive components. The real-time neutron radiography system consists of two major components: a camera and image processing equipment. The neutron beam provides a thermal neutron flux of 10 neutrons/cm -sec (cadmium ratio of 4.0) with the TRIGA reactor operating at a power of 1 MW. A remotely operated turntable is used to position the sample in the neutron beam for optimum viewing and ease of changing position. The front surface mirror at 45 deg. to the neutron beam reflects the scintillation image to the lens. The IRO and CCD camera are placed behind shielding out of the neutron. Results using the imaging system for a cadmium plate (0.032 inch thick) with several holes of different diameters are presented. Applications of this neutron radiography system include sensitivity indicators for the spatial resolution of bubbles in water-filled tubes, moisture content of zeolite samples, operating heat pipes and the freezing and thawing of metallic samples

  1. Factors Influencing the Safety Behavior of German Equestrians: Attitudes towards Protective Equipment and Peer Behaviors

    Directory of Open Access Journals (Sweden)

    Christina-Maria Ikinger

    2016-02-01

    Full Text Available Human interactions with horses entail certain risks. Although the acceptance and use of protective gear is increasing, a high number of incidents and very low or inconsistent voluntary use of safety equipment are reported. While past studies have examined factors influencing the use of safety gear, they have explored neither their influence on the overall safety behavior, nor their relative influence in relation to each other. The aim of the present study is to fill this gap. We conducted an online survey with 2572 participants. By means of a subsequent multiple regression analysis, we explored 23 different variables in view of their influence on the protective behavior of equestrians. In total, we found 17 variables that exerted a significant influence. The results show that both having positive or negative attitudes towards safety products as well as the protective behavior of other horse owners or riding pupils from the stable have the strongest influence on the safety behavior of German equestrians. We consider such knowledge to be important for both scientists and practitioners, such as producers of protective gear or horse sport associations who might alter safety behavior in such a way that the number of horse-related injuries decreases in the long term.

  2. A picture of radiography education across Europe

    International Nuclear Information System (INIS)

    McNulty, J.P.; Rainford, L.; Bezzina, P.; Henner, A.; Kukkes, T.; Pronk-Larive, D.; Vandulek, C.

    2016-01-01

    Purpose: To establish an understanding of radiography education across Europe by surveying higher education institutions registered as affiliate members of the European Federation of Radiography Societies (EFRS). Method: An online survey was developed to ascertain data on: curricula, duration, credit load, accreditation requirements, staff qualifications, staff and student exchange opportunities, and availability of postgraduate programmes. Responses were identifiable in terms of educational institution and country. All 46 affiliated educational institutions were invited to participate in the survey. Descriptive and thematic analyses are reported. Results: A response rate of 89.1% (n = 41) was achieved from educational institutions representing 21 countries. The majority of institutions (63.4%) offer a combined Medical Imaging, Radiotherapy and Nuclear Medicine programme; dedicated Medical Imaging programmes are offered by 14 institutions (34.2%); dedicated Radiotherapy programme by one institution (2.4%), and a dedicated Nuclear Medicine programme by only three institutions (6.5%). The Bologna (Bachelor) cycle has been adopted by 90.2% of responding institutions. The majority of institutions (53.7%) indicated programmes of 3 years in duration, others stated 3.5–4 years. Only 14.6% of institutions require ‘International Level’ accreditation for the Bachelors radiography programme. Postgraduate programmes were not offered by 26.8% of institutions and a deficit in Doctoral status for radiography educators was identified. Conclusions: The Bologna (Bachelor) cycle for radiography education has been adopted across the majority of institutions, however, full alignment remains a priority. Postgraduate radiography education opportunities across Europe appear to be insufficient and further investigation of radiography accreditation processes is justified to ensure harmonisation of practice. - Highlights: • The majority of institutions are compliant with the

  3. 42 CFR Appendix C to Part 75 - Standards for Accreditation of Dental Radiography Training for Dental Assistants

    Science.gov (United States)

    2010-10-01

    ... areas: radiation physics; radiation biology; radiation health, safety, and protection; X-ray films and... 42 Public Health 1 2010-10-01 2010-10-01 false Standards for Accreditation of Dental Radiography Training for Dental Assistants C Appendix C to Part 75 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF...

  4. Controlled area for mobile medical X-ray equipment

    Energy Technology Data Exchange (ETDEWEB)

    Menzel, B; Taschner, P; Koenig, W [Staatliches Amt fuer Atomsicherheit und Strahlenschutz, Berlin (German Democratic Republic); Fuehr, K P; Kucharz, R [Rostock Univ. (German Democratic Republic). Radiologische Klinik

    1976-10-01

    On the basis of dose rate measurements the radiation protection situation during operation of mobile X-ray machines is described. According to these results, the controlled area has been definitely fixed by the National Board of Nuclear Safety and Radiation Protection with respect to the following fields of application: stomatology, mobile radiography of patients confined to bed as well as performing radiological examinations in the operating theatre.

  5. Information extraction from muon radiography data

    International Nuclear Information System (INIS)

    Borozdin, K.N.; Asaki, T.J.; Chartrand, R.; Hengartner, N.W.; Hogan, G.E.; Morris, C.L.; Priedhorsky, W.C.; Schirato, R.C.; Schultz, L.J.; Sottile, M.J.; Vixie, K.R.; Wohlberg, B.E.; Blanpied, G.

    2004-01-01

    Scattering muon radiography was proposed recently as a technique of detection and 3-d imaging for dense high-Z objects. High-energy cosmic ray muons are deflected in matter in the process of multiple Coulomb scattering. By measuring the deflection angles we are able to reconstruct the configuration of high-Z material in the object. We discuss the methods for information extraction from muon radiography data. Tomographic methods widely used in medical images have been applied to a specific muon radiography information source. Alternative simple technique based on the counting of high-scattered muons in the voxels seems to be efficient in many simulated scenes. SVM-based classifiers and clustering algorithms may allow detection of compact high-Z object without full image reconstruction. The efficiency of muon radiography can be increased using additional informational sources, such as momentum estimation, stopping power measurement, and detection of muonic atom emission.

  6. Inter-comparison of safety culture within selected practices in Ghana utilising ionising radiation

    International Nuclear Information System (INIS)

    Faanu, A.; Schandorf, C.; Darko, E. O.; Boadu, M.; Emi-Reynolds, G.; Awudu, A. R.; Gyekye, P. K.; Kpeglo, D. O.

    2010-01-01

    The safety culture of selected practices and facilities in Ghana utilising radiation sources or radiation emitting devices has been assessed using a performance indicator, which provided status information on management and operating staff commitment to safety. The questionnaire was based on the following broad areas: general safety considerations, safety policy at the facility level, safety practices at the facility level, definition of responsibility, staff training, safety of the physical structure of the facility and the emergency plans. The analysis showed that the percentage levels of commitment to safety for the respective practices are as follows: conventional radiography, 23.3-90.0%; research reactor, 73.3 %; gamma irradiation facility, 53.3%; radiotherapy, 76.7%; X-ray scanner, 80.0%; gamma scanner, 76.7%; industrial radiography 86.7% and nuclear density practice, 78%. None of the practices or facilities was able to satisfy all the requirements that will ensure a 100% level of safety culture. (authors)

  7. 30 CFR 75.811 - High-voltage underground equipment; grounding.

    Science.gov (United States)

    2010-07-01

    ...-voltage equipment supplying power to such equipment receiving power from resistance grounded systems shall... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage underground equipment; grounding... COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage...

  8. SIMPLE for industrial radiography

    International Nuclear Information System (INIS)

    Azhar Azmi; Abd Nassir Ibrahim; Siti Madiha Muhammad Amir; Glam Hadzir Patai Mohamad; Saidi Rajab

    2004-01-01

    The first thing industrial radiographers have to do before commencing radiography works is to determine manually the amount of correct exposure that the film need to be exposed in order to obtain the right density. The amount of exposure depends on many variables such as type of radioisotope, type of film, nature of test-object and its orientation, and specific arrangement related to object location and configuration. In many cases radiography works are rejected because of radiographs fail to meet certain reference criteria as defined in the applicable standard. One of the main reasons of radiograph rejection is due to inadequate exposure received by the films. SIMPLE is a software specially developed to facilitate the calculation of gamma-radiography exposure. By using this software and knowing radiographic parameters to be encountered during the work, it is expected that human error will be minimized, thus enhancing the quality and productivity of NDT jobs. (Author)

  9. Apparatus for gamma radiography

    International Nuclear Information System (INIS)

    1983-06-01

    The aim of the present standard is to fix the rules for the construction of gamma radiography instrumentation without prejudice to the present regulations. These apparatus have to be fitted with only sealed sources conformable to the experimental standard M 61-002. The present standard agrees with the international standard ISO 3999 of 1977 dealing with the same subject. Nevertheless, it is different on the three main following points: it does not accept the same limits of absorbed dose rates in the air calculated on the external surface of projectors; it precribes tightness, bending, crushing and tensile tests for some components of the gamma radiography it prescribes tests of endurance and resistance to breaking for the locking systems of the gamma radiography apparatus. The present standard also specifies the following points: symbols and indications to put on projectors and on the source-holder; identification of the source contained in the projector; and, accompanying documents. The regulation references are given in annexe [fr

  10. Plain radiography procedures in Sudan: examination frequency and collective dose

    International Nuclear Information System (INIS)

    Musa, B. E. Y.

    2010-12-01

    According to the previous studies diagnostic examinations are the largest man-made source to collective dose (CED) in world. It was observed that, despite of the large number of medical x-ray installations in Sudan and in particular conventional x-ray procedures, studies aimed at estimating collective effective dose in diagnostic radiology were lacking. The purpose of this study was to estimate the annual frequency of plain radiography examinations and to estimate the annual collective effective dose to Sudanese population due to plain radiography examinations, selected by their high frequencies or their relatively high doses delivered to patient. To have an idea about the typical examinations frequencies, data were collected from a sample of ten hospitals in Khartoum. The collected data provided information about the x-ray machine manufacture, year of installation and frequency of some examinations per day. The annual collective doses from all medical examinations to the population are: 441, 166, 630, 544, 276, 525, 30, 9, 12 and 161 man Sv from abdomen AP, chest AP, pelvis, lumbar spine PA, lumbar spain PA, lumbar- sacral joints, Skull AP, Skull LAT, Skull PA and from others examination, respectively. The resulting annual collective effective dose was evaluated 2793 man Sv, with the largest contribution of pelvis and LS examinations and lowest contribution of skull examinations. Collective effective dose resulting from the use of plain radiography examinations in the Sudan is small compared with global results. But that dose not negate the need to conduct radiological surveys in frequent intervals to meet the increase of successive x-ray equipment to try to estimate and reduce the doses of patients and the public. (Author)

  11. Heavy-ion radiography applied to charged particle radiotherapy

    International Nuclear Information System (INIS)

    Chen, G.T.Y.; Fabrikant, J.I.; Holley, W.R.; Tobias, C.A.; Castro, J.R.

    1980-01-01

    The objectives of the heavy-ion radiography research program applied to the clinical cancer research program of charged particle radiotherapy have a twofold purpose: (1) to explore the manner in which heavy-ion radiography and CT reconstruction can provide improved tumor localization, treatment planning, and beam delivery for radiotherapy with accelerated heavy charged particles; and (2) to explore the usefulness of heavy-ion radiography in detecting, localizing, and sizing soft tissue cancers in the human body. The techniques and procedures developed for heavy-ion radiography should prove successful in support of charged particle radiotherapy

  12. Absorbed doses for patients undergoing panoramic radiography, cephalometric radiography and CBCT

    Directory of Open Access Journals (Sweden)

    Małgorzata Wrzesień

    2017-10-01

    Full Text Available Objectives: Contemporary dental radiology offers a wide spectrum of imaging methods but it also contributes to an increase in the participation of dental radiological diagnosis in the patient’s exposure to ionizing radiation. The aim of this study is to determine the absorbed doses of the brain, spinal column, thyroid and eye lens for patients during panoramic radiography, cephalometric radiography and cone beam computed tomography (CBCT. Material and Methods: The thermoluminescent dosimetry and anthropomorphic phantom was used for measuring the doses. The 15 panoramic, 4 cephalometric and 4 CBCT exposures were performed by placing high-sensitivity thermoluminescent detectors (TLD in 18 anatomical points of the phantom. Results: The maximum absorbed dose recorded during performed measurements corresponds to the point representing the brainstem and it is 10 mGy. The dose value recorded by the TLD placed in the thyroid during CBCT imaging in relation to the panoramic radiography differs by a factor of 13.5. Conclusions: Cone beam computed tomography, in comparison with panoramic or cephalometric imaging technique, provides higher radiation doses to the patients. Int J Occup Med Environ Health 2017;30(5:705–713

  13. Radiation protection for industrial radiography in the aerospace industry

    International Nuclear Information System (INIS)

    Morgan, W.E.

    1980-01-01

    The Boeing Company employs 80 industrial radiographers, operates 90 radiation sources, and takes 10,000 exposures per month. This paper describes the major components of Boeing's radiation protection program: hazard analysis, facilities and equipment design, program administration, and evaluation. In the hazard analysis, each source of radiation is analyzed to determine its hazard and relationship to both man and the environment around it. Once the degree of the hazard is known, facilities and equipment are designed to contain the hazard. This can be anything from a four foot concrete shielded room for an industrial radiographic accelerator, to a piece of rope that isolates an Iridium-192 source during a field radiographic inspection on an aircraft. The administrative functions provide the necessary records, command media, and a radiation source certification program. This certification authorizes the source of radiation to be used under specific conditions agreed upon by both the Radiation Protection Organization and Industrial Radiography Management. The radiation protection program is evaluated through medical exams, personnel monitoring, and area radiation surveys. (H.K.)

  14. Study concerning the power plant control and safety equipment by integrated distributed systems

    International Nuclear Information System (INIS)

    Optea, I.; Oprea, M.; Stanescu, P.

    1995-01-01

    The paper deals with the trends existing in the field of nuclear control and safety equipment and systems, proposing a high-efficiency integrated system. In order to enhance the safety of the plant and reliability of the structure system and components, we present a concept based on the latest computer technology with an open, distributed system, connected by a local area network with high redundancy. A modern conception for the control and safety system is to integrate all the information related to the reactor protection, active engineered safeguard and auxiliary systems parameters, offering a fast flow of information between all the agencies concerned so that situations can be quickly assessed. The integrated distributed control is based on a high performance operating system for realtime applications, flexible enough for transparent networking and modular for demanding configurations. The general design considerations for nuclear reactors instrumentation reliability and testing methods for real-time functions under dynamic regime are presented. Taking into account the fast progress in information technology, we consider the replacement of the old instrumentation of Cernavoda-1 NPP by a modern integrated system as an economical and efficient solution for the next units. (Author) 20 Refs

  15. Normal people working in normal organizations with normal equipment: system safety and cognition in a mid-air collision.

    Science.gov (United States)

    de Carvalho, Paulo Victor Rodrigues; Gomes, José Orlando; Huber, Gilbert Jacob; Vidal, Mario Cesar

    2009-05-01

    A fundamental challenge in improving the safety of complex systems is to understand how accidents emerge in normal working situations, with equipment functioning normally in normally structured organizations. We present a field study of the en route mid-air collision between a commercial carrier and an executive jet, in the clear afternoon Amazon sky in which 154 people lost their lives, that illustrates one response to this challenge. Our focus was on how and why the several safety barriers of a well structured air traffic system melted down enabling the occurrence of this tragedy, without any catastrophic component failure, and in a situation where everything was functioning normally. We identify strong consistencies and feedbacks regarding factors of system day-to-day functioning that made monitoring and awareness difficult, and the cognitive strategies that operators have developed to deal with overall system behavior. These findings emphasize the active problem-solving behavior needed in air traffic control work, and highlight how the day-to-day functioning of the system can jeopardize such behavior. An immediate consequence is that safety managers and engineers should review their traditional safety approach and accident models based on equipment failure probability, linear combinations of failures, rules and procedures, and human errors, to deal with complex patterns of coincidence possibilities, unexpected links, resonance among system functions and activities, and system cognition.

  16. Environmental qualification - walkdowns: The documentation of configuration information for safety related components, equipment and systems

    International Nuclear Information System (INIS)

    Melmer, J.; Waters, M.

    1995-01-01

    Environmental Qualification walkdowns are conducted to collect field data to verify/validate/document configurations of safety related equipment and systems. This paper describes the process for conducting walkdowns and the justification for using an electronic format. The following are described: a) Background; b) Preparing, executing and processing walkdowns; c) Hardware/software; d) Impact of a paperless system on walkdown execution, maintenance and work planning; e) Other applications for the technology

  17. Estimation of Absorbed Dose in Occlusal Radiography

    International Nuclear Information System (INIS)

    Yoo, Young Ah; Choi, Karp Shick; Lee, Sang Han

    1990-01-01

    The purpose of this study was to estimate absorbed dose of each important anatomic site of phantom (RT-210 Head and Neck Section R, Humanoid Systems Co., U.S.A.) head in occlusal radiography. X-radiation dosimetry at 12 anatomic sites in maxillary anterior topography, maxillary posterior topography, mandibular anterior cross-section, mandibular posterior cross-section, mandibular anterior topographic, mandibular posterior topographic occlusal projection was performed with calcium sulfate thermoluminescent dosimeters under 70 Kvp and 15 mA, 1/4 second (8 inch cone ) and 1 second (16 inch cone) exposure time. The results obtained were as follows: Skin surface produced highest absorbed dose ranged between 3264 mrad and 4073 mrad but there was little difference between projections. In maxillary anterior topographic occlusal radiography, eyeballs, maxillary sinuses, and pituitary gland sites produced higher absorbed doses than those of other sites. In maxillary posterior topographic occlusal radiography, exposed eyeball site and exposed maxillary sinus site produced high absorbed doses. In mandibular anterior cross-sectional occlusal radiography, all sites were produced relatively low absorbed dose except eyeball sites. In Mandibular posterior cross-sectional occlusal radiography, exposed eyeball site and exposed maxillary sinus site were produced relatively higher absorbed doses than other sites. In mandibular anterior topographic occlusal radiography, maxillary sinuses, submandibular glands, and thyroid gland sites produced high absorbed doses than other sites. In mandibular posterior topographic occlusal radiography, submandibular gland site of the exposed side produced high absorbed dose than other sites and eyeball site of the opposite side produced relatively high absorbed dose.

  18. Which technologies to replace gamma radiography?

    International Nuclear Information System (INIS)

    Zani-Demange, M.L.; Chauveau, D.

    2012-01-01

    Gamma radiography with iridium source is largely used in the industrial sector for the control of welds, tubes and pressure vessels as well as for monitoring corrosion. Hazards due to the handling of ionizing radiation sources (Ir 192 ) and constraints due to a more and more demanding regulations call for alternative methods. The French 'Institut de soudure' has led a 4-year long study (Alter-X project) and has identified 3 alternative methods for the iridium gamma radiography: -) the TOFD (Time Of Flight Diffraction) which is based on the analysis of the diffraction of ultrasound waves on the edges of defects; -) phased array ultrasound which is based on a series of elementary sensors that can be handled in an individual manner by specific electronics, the sweeping is no more manual but electronic and enables the operator to localize and size defects deep under the surface; -) digit radiography that is a common radiography in which the film is replaced by a re-usable phosphorus screen that is more sensitive and can be easily digitalized and has no need for a chemical treatment to be read. Digit radiography used with Se 75 (another gamma emitter) gives comparable or even better results than with Ir 192 but with a dose rate cut by half at least. (A.C.)

  19. Seismic qualification of equipment in operating nuclear power plants. Unresolved safety issue A-46, draft report for comment

    International Nuclear Information System (INIS)

    Chang, T.Y.

    1985-08-01

    The margin of safety provided in existing nuclear power plant equipment to resist seismically induced loads and perform their intended safety functions may vary considerably, because of significant changes in design criteria and methods for the seismic qualification of equipment over the years. Therefore, the seismic qualification of equipment in operating plants should be reassessed to determine whether requalification is necessary. The objective of technical studies performed under the Task Action Plan A-46 was to establish an explicit set of guidelines and acceptance criteria to judge the adequacy of equipment under seismic loading at all operating plants, in lieu of requiring qualification to the current criteria that are applied to new plants. This report summarizes the work accomplished on USI A-46 by the Nuclear Regulatory Commission staff and its contractors, Idaho National Engineering Laboratory, Southwest Research Institute, Brookhaven National Laboratory, and Lawrence Livermore National Laboratory. In addition, the collection and review of seismic experience data by the Seismic Qualification Utility Group and the review and recommendations of a group of seismic consultants, the Senior Seismic Review Advisory Panel, are presented. Staff assessment of work accomplished under USI A-46 leads to the conclusion that the use of seismic experience data provides the most reasonable alternative to current qualification criteria. Consideration of seismic qualification by use of experience data was a specific task in USI A-46. Several other A-46 tasks serve to support the use of an experience data base

  20. Neutron radiography at the SCK/CEN

    International Nuclear Information System (INIS)

    Tourwe, H.

    1977-01-01

    Neutron radiography has become in recent years a very important method of nondestructive testing in industry and research. The earliest practical application of neutron radiography has probably been the inspection of highly radioactive material: originally irradiated reactor fuels. Applications then progressed to other nuclear and industrial inspection problems. Neutron radiography and the conventional X-ray or gamma techniques are complementary. Some of the most important application fields of neutron radiography are: the detection of light elements (H, Li, B,...) with a very high scattering of absorption cross section for thermal neutrons; the nondestructive control of fuel before and after irradiation; controls where a distinction has to be made between isotopes of the same element ( 235 U and 238 U, 10 B and 11 B,...) and between components of a similar atomic number (Fe and Zn); the control of materials with a high density; the study of corrosion in closed structures; the control of the homogeneity of foreign materials in alloys,.... (author)

  1. Direct detector radiography versus dual reading computed radiography: feasibility of dose reduction in chest radiography

    International Nuclear Information System (INIS)

    Gruber, Michael; Uffmann, Martin; Weber, Michael; Balassy, Csilla; Schaefer-Prokop, Cornelia; Prokop, Mathias

    2006-01-01

    The image quality of dual-reading computed radiography and dose-reduced direct radiography of the chest was compared in a clinical setting. The study group consisted of 50 patients that underwent three posteroanterior chest radiographs within minutes, one image obtained with a dual read-out computed radiography system (CR; Fuji 5501) at regular dose and two images with a flat panel direct detector unit (DR; Diagnost, Philips). The DR images were obtained with the same and with 50% of the dose used for the CR images. Images were evaluated in a blinded side-by-side comparison. Eight radiologists ranked the visually perceivable difference in image quality using a three-point scale. Then, three radiologists scored the visibility of anatomic landmarks in low and high attenuation areas and image noise. Statistical analysis was based on Friedman tests and Wilcoxon rank sum tests at a significance level of P<0.05. DR was judged superior to CR for the delineation of structures in high attenuation areas of the mediastinum even when obtained with 50% less dose (P<0.001). The visibility of most pulmonary structures was judged equivalent with both techniques, regardless of acquisition dose and speed level. Scores for image noise were lower for DR compared with CR, with the exception of DR obtained at a reduced dose. Thus, in this clinical preference study, DR was equivalent or even superior to the most modern dual read-out CR, even when obtained with 50% dose. A further dose reduction does not appear to be feasible for DR without significant loss of image quality. (orig.)

  2. Dual-energy subtraction radiography of the breast

    International Nuclear Information System (INIS)

    Asaga, Taro; Masuzawa, Chihiro; Kawahara, Satoru; Motohashi, Hisahiko; Okamoto, Takashi; Tamura, Nobuo

    1988-01-01

    Dual-energy projection radiography was applied to breast examination. To perform the dual-energy subtraction radiography using a digital radiography unit, high and low-energy exposures were made at an appropriate time interval under differing X-ray exposure conditions. Dual-energy subtraction radiography was performed in 41 cancer patients in whom the tumor shadow was equivocal or the border of cancer infiltration was not clearly demonstrated by compression mammography, and 15 patients with benign diseases such as fibrocystic disease, cyst and fibroadenoma. In 21 cases out of the 41 cancer patients, the dual-energy subtraction radiography clearly visualized the malignant tumor shadows and the border of cancer infiltration and the daughter nodules by removing the shadows of normal mammary gland. On the other hand, beign diseases such as fibrocystic disease and cyst could be diagnosed as such, because the tumor shadow and the irregularly concentrated image of mammary gland disappeared by the dual-energy subtraction. These results suggest that this new technique will be useful in examination of breast masses. (author)

  3. Dual-energy subtraction radiography of the breast

    Energy Technology Data Exchange (ETDEWEB)

    Asaga, Taro; Masuzawa, Chihiro; Kawahara, Satoru; Motohashi, Hisahiko; Okamoto, Takashi; Tamura, Nobuo

    1988-06-01

    Dual-energy projection radiography was applied to breast examination. To perform the dual-energy subtraction radiography using a digital radiography unit, high and low-energy exposures were made at an appropriate time interval under differing X-ray exposure conditions. Dual-energy subtraction radiography was performed in 41 cancer patients in whom the tumor shadow was equivocal or the border of cancer infiltration was not clearly demonstrated by compression mammography, and 15 patients with benign diseases such as fibrocystic disease, cyst and fibroadenoma. In 21 cases out of the 41 cancer patients, the dual-energy subtraction radiography clearly visualized the malignant tumor shadows and the border of cancer infiltration and the daughter nodules by removing the shadows of normal mammary gland. On the other hand, beign diseases such as fibrocystic disease and cyst could be diagnosed as such, because the tumor shadow and the irregularly concentrated image of mammary gland disappeared by the dual-energy subtraction. These results suggest that this new technique will be useful in examination of breast masses.

  4. Neutron radiography for nondestructive testing

    International Nuclear Information System (INIS)

    John, J.

    1979-01-01

    Neutron radiography is similar to X-ray inspection in that both depend upon use of radiation that penetrates some materials and is absorbed by others to provide a contrast image of conditions not readily available for visual inspection. X-rays are absorbed by dense materials, such as metals, whereas neutrons readily penetrate metals, but are absorbed by materials containing hydrogen. The neutron radiography has been successfully applied to a number of inspection situations. These include the inspection of explosives, advanced composites, adhesively bonded structures and a number of aircraft engine components. With the availability of Californium-252, it has become feasible to construct mobile neutron radiography systems suitable for field use. Such systems have been used for in-situ inspection of flight line aircraft, particularly to locate and measure hidden corrosion

  5. New north beam tube for the neutron radiography reactor

    International Nuclear Information System (INIS)

    Pruett, D.P.; Richards, W.J.; Heidel, C.C.

    1982-01-01

    Neutron radiography of the fuel undergoing examination in the argon cell is performed in the NRAD Facility and is one of many examinations performed on the fuel. The reactor and examination procedure are described. The new radiography system, developed to expand the present radiography capabilities to radiograph both irradiated and unirradiated specimens and to provide for the development of new radiography techniques without interfering with the argon cell production schedule is presented

  6. Quantitative film radiography

    International Nuclear Information System (INIS)

    Devine, G.; Dobie, D.; Fugina, J.; Hernandez, J.; Logan, C.; Mohr, P.; Moss, R.; Schumacher, B.; Updike, E.; Weirup, D.

    1991-01-01

    We have developed a system of quantitative radiography in order to produce quantitative images displaying homogeneity of parts. The materials that we characterize are synthetic composites and may contain important subtle density variations not discernible by examining a raw film x-radiograph. In order to quantitatively interpret film radiographs, it is necessary to digitize, interpret, and display the images. Our integrated system of quantitative radiography displays accurate, high-resolution pseudo-color images in units of density. We characterize approximately 10,000 parts per year in hundreds of different configurations and compositions with this system. This report discusses: the method; film processor monitoring and control; verifying film and processor performance; and correction of scatter effects

  7. Usefulness of inverter type REX-650 R/F X-ray equipment

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Min; Oh, Jung Hwan [College of Health Sceince, Korea University, Seoul (Korea, Republic of)

    2003-06-15

    The conclusions after appraisal usefulness of Korean 30 kHz inverter type X-ray equipment which are currently used in the clinics are like those followings. The specific characters of mA, kVp, msec in the radiography keep very good accuracy and showed good waveform also under KS regulations. The output of the X-ray equipment is showed 1.7 times higher than single-phase. mA, kVp of the fluoroscopy and Sopt film exposure mA, kVp showed appropriated result under the regulations. As we consider the conversion factor of image intensifier tube used for two years, it showed pretty high results, 310 at 75 kV, and knew that the conversion factor which followed by increasing kVp increased its computations like Kim's experimentation. Those X-ray equipment showed excellent results in the appraisal while those were operating so we think that those X-ray equipment will be substitute for expensive foreign equipment in Korean domestic medical equipment in the future.

  8. Evaluation of Generic Issue 57: Effects of fire protection system actuation on safety-related equipment

    International Nuclear Information System (INIS)

    Lambright, J.; Bohn, M.; Lynch, J.; Ross, S.; Brosseau, D.

    1992-12-01

    Nuclear power plants have experienced actuations of fire protection systems (FPSs) under conditions for which these systems were not intended to actuate and also have experienced advertent actuations with the presence of a fire. These actuations have often damaged safety-related equipment. A review of the impact of past occurrences of both types of such events and their impact on plant safety systems, an analysis of the risk impacts of such events on nuclear power plant safety, and a cost-benefit analysis of potential corrective measures have been performed. Thirteen different scenarios leading to actuation of fire protection systems due to a variety of causes were identified. These scenarios ranged from inadvertent actuation caused by human error to hardware failure, and include seismic root causes and seismic/fire interactions. A quantification of these thirteen root causes, where applicable, was performed on generically applicable scenarios. This document, Volume 4, contains appendices E and F of this report

  9. Neutron radiography at the Risoe National Laboratory

    International Nuclear Information System (INIS)

    Domanus, J.C.; Gade-Nielsen, P.; Knudsen, P.; Olsen, J.

    1981-11-01

    In this report six papers are collected which will be presented at the First World Conference on Neutron Radiography in San Diego, U.S.A., 7 - 10 December 1981. They are preceded by a short description of the activities of Risoe National Laboratory in the field of post-irradiation examination of nuclear fuel. One of the nondestructive methods used for this examination is neutron radiography. In the six conference papers different aspects of neutron radiography performed at Risoe are presented. (author)

  10. Facial exposure dose assessment during intraoral radiography by radiological technologists

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Hwan; Yang, Han Joon [Dept. of International Radiological Science, Hallym University of Graduate Studies, Chuncheon (Korea, Republic of)

    2014-09-15

    The study examined the changes in the decreased facial exposure dose for radiological technologists depending on increased distance between the workers and the X-ray tube head during intraoral radiography. First, the facial phantom similar to the human tissues was manufactured. The shooting examination was configured to the maxillary molars for adults (60 kVp, 10 mA, 50 msec) and for children (60 kVp, 10 mA, 20 msec), and the chamber was fixed where the facial part of the radiation worker would be placed using the intraoral radiography equipment. The distances between the X-ray tube head and the phantom were set to 10 cm, 15 cm, 20 cm, 25 cm, 30 cm, 35 cm, and 40 cm. The phantom was radiated 20 times with each examination condition and the average scattered doses were examined. The rate at the distance of 40 cm decreased by about 92.6% to 7.43% based on the scattered rays radiated at the distance of 10 cm under the adult conditions. The rate at the distance of 40 cm decreased by about 97.6% to 2.58% based on the scattered rays radiated at the distance of 10 cm under the children conditions. Protection from the radiation exposure was required during the dental radiographic examination.

  11. Digital radiography

    International Nuclear Information System (INIS)

    Brody, W.R.

    1984-01-01

    Digital Radiography begins with an orderly introduction to the fundamental concepts of digital imaging. The entire X-ray digital imagining system is described, from an overall characterization of image quality to specific components required for a digital radiographic system. Because subtraction is central to digital radiographic systems, the author details the use of various subtraction methods for image enhancement. Complex concepts are illustrated with numerous examples and presented in terms that can readily be understood by physicians without an advanced mathematics background. The second part of the book discusses implementations and applications of digital imagining systems based on area and scanned detector technologies. This section includes thorough coverage of digital fluoroscopy, scanned projection radiography, and film-based digital imaging systems, and features a state-of-the-art synopsis of the applications of digital subtraction angiography. The book concludes with a timely assessment of anticipated technological advances

  12. Direct magnification radiography of the hand

    International Nuclear Information System (INIS)

    Presacco, D.; Pellegrini, A.; Di Maggio, C.

    1987-01-01

    The value of direct magnification radiography of the hand and the wrist has been studied in 128 patients affected by rheumatic diseases. Only in a small group (3.17%) magnification determined a higher percentage of correct diagnosis; in the 17.06% of cases direct magnification radiography provided useful increase in information but did not change the diagnisis correctly reached by conventional techniques. In most cases (79.76%) magnification provided only a better image quality but no more information helpful for the diagnosis, because of the high level achieved by convetional techniques. Therefore direct magnification radiography must be used only in selected cases and not as routine radiographyc technique

  13. Pediatric radiation dose management in digital radiography

    International Nuclear Information System (INIS)

    Neitzel, U.

    2004-01-01

    Direct digital radiography (DR) systems based on flat-panel detectors offer improved dose management in pediatric radiography. Integration of X-ray generation and detection in one computer-controlled system provides better control and monitoring

  14. Hoisting appliances and fuel handling equipment at nuclear facilities

    International Nuclear Information System (INIS)

    1987-01-01

    The guide is followed by the Finnish Centre for Radiation and Nuclear Safety (STUK) in regulating hoisting and handling equipment Class 3 at nuclear facilities. The guide is applied e.g. to the following equipment: reactor building overhead cranes, hoisting appliances at nuclear fuel storages, fuel handling machines, other hoisting appliances, which because of nuclear safety aspects are classified in Safety Class 3, and load-bearing devices connected with the above equipment, such as replaceable hoisting tools and auxiliary lifting devices. The regulating of hoisting and handling equipment comprises the following stages: handling of preliminary and final safety analysis reports, inspection of the construction plan, supervision of fabrication and construction inspection, and supervision of initial start-up and commissioning inspection

  15. Regulatory analysis for the resolution of generic issue 57: Effects of Fire Protection System Actuation on Safety-Related Equipment

    International Nuclear Information System (INIS)

    Woods, H.W.

    1993-10-01

    Actuation of Fire Protection Systems (FPS) in Nuclear Power Plants have resulted in adverse interactions with equipment important to safety. Precursor operational experience has shown that 37% of all FPS actuations damaged some equipment, and 20% of all FPS actuations have resulted in a plant transient and reactor trip. On an average 0.17 FPS actuations per reactor year have been experienced in nuclear power plants in this country. This report presents the regulatory analysis for GI-57, ''Effects of Fire Protection System Actuation on Safety-Related Equipment''. The risk reduction estimates, cost/benefit analyses, and other insights gained during this effort have shown that implementation of the recommendations contained in this report can significantly reduce risk, and that these improvements can be warranted in accordance with the backfit rule, 10 CFR 50.109(a)(3). However, plant specific analyses are required in order to identify such improvements. Generic analyses can not serve to identify improvements that could be warranted for individual, specific plants. Plant specific analyses of the type needed for this purpose are underway as part of the Individual Plant Examination of External Events (IPEEE) program

  16. Construction of a physical phantom for quality control of digital radiography images

    International Nuclear Information System (INIS)

    Santos, Tayline T.; Azevedo, Priscila F.B. de; Vieira, Jose Wilson; Oliveira, Alex C.H. de; Lima, Fernando R. Andrade

    2014-01-01

    The advancement of technology in recent years has the production of increasingly sophisticated devices, in order thus to obtain medical images with high technical level and also facilitate the operation of the equipment. The phantoms were created to ensure a more accurate diagnosis with the minimum dose without exposing patients. Also, to obtain data and verify the performance of a radiography system with a view to ensuring the quality control standards. The objective of this paper is to present and validate a methodology for the construction of a phantom for the control of digital quality radiographic image. (author)

  17. Construction of a physical phantom for quality control of digital radiography images

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Tayline T.; Azevedo, Priscila F.B. de; Vieira, Jose Wilson, E-mail: taylinetyene@hotmail.com, E-mail: priscilafbrasil@yahoo.com.br [Instituto Federal de Educacao, Ciencia e Tecnologia de Pernambuco (IFPE), Recife, PE (Brazil); Oliveira, Alex C.H. de; Lima, Fernando R. Andrade, E-mail: falima@cnen.gov.br [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2014-07-01

    The advancement of technology in recent years has the production of increasingly sophisticated devices, in order thus to obtain medical images with high technical level and also facilitate the operation of the equipment. The phantoms were created to ensure a more accurate diagnosis with the minimum dose without exposing patients. Also, to obtain data and verify the performance of a radiography system with a view to ensuring the quality control standards. The objective of this paper is to present and validate a methodology for the construction of a phantom for the control of digital quality radiographic image. (author)

  18. Application of neutron radiography in Japan

    International Nuclear Information System (INIS)

    Kobayashi, M.; Wada, N.; Sekita, J.; Sanno-cho, Ota-ku, Tokyo, Japan)

    1983-01-01

    The history and the present state of neutron radiography in Japan are reviewed. Three types of neutron sources, namely nuclear reactors, accelerators and radioisotopes are now used. The interests on the application on neutron radiography become greater and greater in the industries, such as atomic energy, aeronautics and space etc. (Auth.)

  19. Ongoing quality control in digital radiography: Report of AAPM Imaging Physics Committee Task Group 151

    International Nuclear Information System (INIS)

    Jones, A. Kyle; Geiser, William; Heintz, Philip; Goldman, Lee; Jerjian, Khachig; Martin, Melissa; Peck, Donald; Pfeiffer, Douglas; Ranger, Nicole; Yorkston, John

    2015-01-01

    Quality control (QC) in medical imaging is an ongoing process and not just a series of infrequent evaluations of medical imaging equipment. The QC process involves designing and implementing a QC program, collecting and analyzing data, investigating results that are outside the acceptance levels for the QC program, and taking corrective action to bring these results back to an acceptable level. The QC process involves key personnel in the imaging department, including the radiologist, radiologic technologist, and the qualified medical physicist (QMP). The QMP performs detailed equipment evaluations and helps with oversight of the QC program, the radiologic technologist is responsible for the day-to-day operation of the QC program. The continued need for ongoing QC in digital radiography has been highlighted in the scientific literature. The charge of this task group was to recommend consistency tests designed to be performed by a medical physicist or a radiologic technologist under the direction of a medical physicist to identify problems with an imaging system that need further evaluation by a medical physicist, including a fault tree to define actions that need to be taken when certain fault conditions are identified. The focus of this final report is the ongoing QC process, including rejected image analysis, exposure analysis, and artifact identification. These QC tasks are vital for the optimal operation of a department performing digital radiography

  20. Electronic device for automatic control of exposure in radiography

    International Nuclear Information System (INIS)

    Pendharkar, A.S.; Jayakumar, T.K.

    1977-01-01

    An electronic instrument for calculating and controlling exposure in radiography practice using radioisotopes is described. When using this equipment, only factor to be known is the dose required by the film for a given density and the thickness of material inspected. It eliminates all the problems arising out of various parameters such as source decay etc in the conventional procedure for calculating exposure time. Principle of operation, the electronic circuitry adopted and the functional aspects of the system are described in detail. Exposure doses for different industrial films have been related to the instrumental readouts. The system reproducibility and reliability have been evaluated. The advantages and limitations of the present system and the future development to overcome the problems are indicated. (author)