WorldWideScience

Sample records for radiographic hydrodynamic test

  1. Dual Axis Radiographic Hydrodynamic Test Facility mitigation action plan. Annual report for 1998

    Energy Technology Data Exchange (ETDEWEB)

    Haagenstad, T.

    1999-01-15

    This Mitigation Action Plan Annual Report (MAPAR) has been prepared as part of implementing the Dual Axis Radiographic Hydrodynamic Test Facility (DARHT) Mitigation Action Plan (MAP) to protect workers, soils, water, and biotic and cultural resources in and around the facility.

  2. Dual Axis Radiographic Hydrodynamic Test Facility mitigation action plan. Annual report for 1998

    International Nuclear Information System (INIS)

    Haagenstad, T.

    1999-01-01

    This Mitigation Action Plan Annual Report (MAPAR) has been prepared as part of implementing the Dual Axis Radiographic Hydrodynamic Test Facility (DARHT) Mitigation Action Plan (MAP) to protect workers, soils, water, and biotic and cultural resources in and around the facility

  3. Dual axis radiographic hydrodynamic test facility. Final environmental impact statement, Volume 2: Public comments and responses

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-08-01

    On May 12, 1995, the U.S. Department of Energy (DOE) issued the draft Dual Axis Radiographic Hydrodynamic Test Facility Environmental Impact Statement (DARHT EIS) for review by the State of New Mexico, Indian Tribes, local governments, other Federal agencies, and the general public. DOE invited comments on the accuracy and adequacy of the draft EIS and any other matters pertaining to their environmental reviews. The formal comment period ran for 45 days, to June 26, 1995, although DOE indicated that late comments would be considered to the extent possible. As part of the public comment process, DOE held two public hearings in Los Alamos and Santa Fe, New Mexico, on May 31 and June 1, 1995. In addition, DOE made the draft classified supplement to the DARHT EIS available for review by appropriately cleared individuals with a need to know the classified information. Reviewers of the classified material included the State of New Mexico, the U.S. Environmental Protection Agency, the Department of Defense, and certain Indian Tribes. Volume 2 of the final DARHT EIS contains three chapters. Chapter 1 includes a collective summary of the comments received and DOE`s response. Chapter 2 contains the full text of the public comments on the draft DARHT EIS received by DOE. Chapter 3 contains DOE`s responses to the public comments and an indication as to how the comments were considered in the final EIS.

  4. Dual Axis Radiographic Hydrodynamic Test Facility mitigation action plan. Annual report for 1997

    Energy Technology Data Exchange (ETDEWEB)

    Haagenstad, H.T.

    1998-01-15

    This Mitigation Action Plan Annual Report (MAPAR) has been prepared by the US Department of Energy (DOE) as part of implementing the Dual Axis Radiographic Hydrodynamic Test Facility (DARHT) Mitigation Action Plan (MAP). This MAPAR provides a status on specific DARHT facility design- and construction-related mitigation actions that have been initiated in order to fulfill DOE`s commitments under the DARHT MAP. The functions of the DARHT MAP are to (1) document potentially adverse environmental impacts of the Phased Containment Option delineated in the Final EIS, (2) identify commitments made in the Final EIS and ROD to mitigate those potential impacts, and (3) establish Action Plans to carry out each commitment (DOE 1996). The DARHT MAP is divided into eight sections. Sections 1--5 provide background information regarding the NEPA review of the DARHT project and an introduction to the associated MAP. Section 6 references the Mitigation Action Summary Table which summaries the potential impacts and mitigation measures; indicates whether the mitigation is design-, construction-, or operational-related; the organization responsible for the mitigation measure; and the projected or actual completion data for each mitigation measure. Sections 7 and 8 discuss the Mitigation Action Plan Annual Report and Tracking System commitment and the Potential Impacts, Commitments, and Action Plans respectively. Under Section 8, potential impacts are categorized into five areas of concern: General Environment, including impacts to air and water; Soils, especially impacts affecting soil loss and contamination; Biotic Resources, especially impacts affecting threatened and endangered species; Cultural/Paleontological Resources, especially impacts affecting the archeological site known as Nake`muu; and Human Health and Safety, especially impacts pertaining to noise and radiation. Each potential impact includes a brief statement of the nature of the impact and its cause(s). The commitment

  5. Radiographic Test

    Energy Technology Data Exchange (ETDEWEB)

    Lee, H.J; Yang, S.H. [Korea Electric Power Research Institute, Taejon (Korea)

    2002-07-01

    This report contains theory, procedure technique and interpretation of radiographic examination and written for whom preparing radiographic test Level II. To determine this baseline of technical competence in the examination, the individual must demonstrate a knowledge of radiography physics, radiation safety, technique development, radiation detection and measurement, facility design, and the characteristics of radiation-producing devices and their principles of operation. (author) 98 figs., 23 tabs.

  6. Radiographic testing

    International Nuclear Information System (INIS)

    Kuster, J.

    1978-01-01

    In view of great differencies in X-ray transmission it is more difficult to get optimum radiographs of plastics and especially of reinforced plastics than for example of metals. A procedure will be reported how to get with little effort optimum radiographs especially also in the range of long wave-length radiation corresponding 10 to 25 kV.P. (orig.) [de

  7. Radiographic testing of wood

    International Nuclear Information System (INIS)

    Osterloh, K.; Zscherpel, U.; Raedel, C.; Weidemann, G.; Meinel, D.; Goebbels, J.; Ewert, U.; Hasenstab, A.; Buecherl, T.

    2007-01-01

    Wood is an old and established consumption and construction material. It is still the most common material for constructing furniture, roofs, playgrounds and mine supports. In contrast to steel and concrete, wood warns of extreme loads by creaking. Its mechanical stability is more influenced by decay than by peripheral cracks. While external cracks are visible, internal decay by fungus growth is undetectable from outside. This may be a safety problem in supporting structures. The best analysis of the internal structure is provided by computed tomography, but this is also the most complex method, much more so than simple radiographic testing. However, the latter is made inaccurate by scattered radiation resulting from internal moisture. With the image processing options of digital radiographic techniques, the structural information can be separated effectively from noise. In contrast to X-ray and gamma radiography, neutron radiography provides information on the spatial distribution of moisture. In healthy wood, water is conducted in the sapwood while the hardwood is dry. Moisture in hardwood is caused by infestations, e.g. fungus growth. The contribution presents a comparative analysis of the available radiographic methods. (orig.)

  8. Concentrations of Radionuclides and Trace Elements in Environmantal Media arond te Dual-Axis Radiographic Hydrodynamic Test Facilit at Los Alamos National Laboratory during 2005

    Energy Technology Data Exchange (ETDEWEB)

    G.J.Gonzales; P.R. Fresquez; C.D.Hathcock; D.C. Keller

    2006-05-15

    The Mitigation Action Plan (MAP) for the Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility at Los Alamos National Laboratory requires that samples of biotic and abiotic media be collected after operations began to determine if there are any human health or environmental impacts. The DARHT facility is the Laboratory's principal explosive test facility. To this end, samples of soil and sediment, vegetation, bees, and birds were collected around the facility in 2005 and analyzed for concentrations of {sup 3}H, {sup 137}Cs, {sup 90}Sr, {sup 238}Pu, {sup 239,240}Pu, {sup 241}Am, {sup 234}U, {sup 235}U, {sup 238}U, Ag, As, Ba, Be, Cd, Cr, Cu, Hg, Ni, Pb, Sb, Se, and Tl. Bird populations have also been monitored. Contaminant results, which represent up to six sample years since the start of operations, were compared with (1) baseline statistical reference levels (BSRLs) established over a four-year preoperational period before DARHT facility operations, (2) screening levels (SLs), and (3) regulatory standards. Most radionuclides and trace elements were below BSRLs and those few samples that contained radionuclides and trace elements above BSRLs were below SLs. Concentrations of radionuclides and nonradionuclides in biotic and abiotic media around the DARHT facility do not pose a significant human health hazard. The total number of birds captured and number of species represented were similar in 2003 and 2004, but both of these parameters increased substantially in 2005. Periodic interruption of the scope and schedule identified in the MAP generally should have no impact on meeting the intent of the MAP. The risk of not sampling one of the five media in any given year is that if a significant impact to contaminant levels were to occur there would exist a less complete understanding of the extent of the change to the baseline for these media and to the ecosystem as a whole. Since the MAP is a requirement that was established under the regulatory framework of

  9. Radiographic testing in concrete structures

    International Nuclear Information System (INIS)

    Oliveira, D. de

    1987-01-01

    The radiographic testing done in concrete structures is used to analyse the homogeneity, position and corrosion of armatures and to detect discontinuity in the concrete such as: gaps, cracks and segregations. This work develops a Image quality Indicator (IQI) with an adequated sensibility to detect discontinuites based on BS4408 norm. (E.G.) [pt

  10. Radiographic testing of concrete

    International Nuclear Information System (INIS)

    Porter, James F.

    1997-01-01

    The increase in construction activity in the Philippines, reinforced concrete building is still a favorite among designers, because it is much cheaper to build and it requires qualified welders, etc. and extensive nondestructive testing and inspection of metals, welds and castings. Of all the techniques radiography is widely used for concrete

  11. Radiographic testing at Lawrence Livermore National Laboratory

    International Nuclear Information System (INIS)

    Bossi, R.H.

    1982-01-01

    Radiographic testing is a nondestructive inspection technique which uses penetrating radiation. The Nondestructive Evaluation (NDE) Section at Lawrence Livermore National Laboratory has a broad spectrum of equipment and techniques for radiographic testing. These resources include low-energy vacuum systems, low- and mid-energy cabinet and cell radiographic systems, high-energy linear accelerators, portable x-ray machines and radioisotopes for radiographic inspections. For diagnostic testing the NDE Section also has real-time and flash radiographic equipment

  12. Observer POD for radiographic testing

    Energy Technology Data Exchange (ETDEWEB)

    Kanzler, Daniel; Mueller, Christina; Bertovic, Marija [Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin (Germany); Pitkaenen, Jorma [Posiva Oy, Eurajoki (Finland)

    2013-07-01

    The radiographic testing is an important non-destructive testing method, especially in industrial areas where people could be injured in case of failing of a component. There it is a mighty method to find volumetric defects. As bigger the penetrated length of the defect in the component is, as bigger is the radiographic contrast. The detectability of volumetric defects in its turn is not only depending on the contrast but also on the noise, the defect area and its shape. The currently applied POD approach uses mostly only the contrast and the noise as detection threshold. This does not reflect accurately the results of evaluations by human observers. A new approach is introduced, using the widely applied POD evaluation and additionally a detection threshold depending on the area of the defect. The presentation shows the process of calculating the POD curves with simulated data by the modeling software aRTist and with artificial reference data. This approach was developed within a joint project with the company POSIVA, which is constructing a final depository for high active nuclear fuels in Finland. Radiographic testing is one of the NDT-methods they use to test the electron beam welds of the copper canisters. The copper canisters will be used in the depository as a corrosion barrier within the waste management concept. (Published as a poster session.)

  13. Inductive voltage adder advanced hydrodynamic radiographic technology demonstration

    International Nuclear Information System (INIS)

    Mazarakis, M.G.; Poukey, J.W.; Maenchen; Rovang, D.C.

    1997-04-01

    This paper presents the design, results, and analysis of a high-brightness electron beam technology demonstration experiment completed at Sandia National Laboratories, performed in collaboration with Los Alamos National Laboratory. The anticipated electron beam parameters were: 12 MeV, 35-40 kA, 0.5-mm rms radius, and 40-ns full width half maximum (FWHM) pulse duration. This beam, on an optimum thickness tantalum converter, should produce a very intense x-ray source of ∼ 1.5-mm spot size and 1 kR dose at sign 1 m. The accelerator utilized was SABRE, a pulsed inductive voltage adder, and the electron source was a magnetically immersed foilless electron diode. For these experiments, SABRE was modified to high-impedance negative-polarity operation. A new 100-ohm magnetically insulated transmission line cathode electrode was designed and constructed; the cavities were rotated 180 degrees poloidally to invert the central electrode polarity to negative; and only one of the two pulse forming lines per cavity was energized. A twenty- to thirty-Tesla solenoidal magnet insulated the diode and contained the beam at its extremely small size. These experiments were designed to demonstrate high electron currents in submillimeter radius beams resulting in a high-brightness high-intensity flash x-ray source for high-resolution thick-object hydrodynamic radiography. The SABRE facility high-impedance performance was less than what was hoped. The modifications resulted in a lower amplitude (9 MV), narrower-than-anticipated triangular voltage pulse, which limited the dose to ∼ 20% of the expected value. In addition, halo and ion-hose instabilities increased the electron beam spot size to > 1.5 mm. Subsequent, more detailed calculations explain these reduced output parameters. An accelerator designed (versus retrofit) for this purpose would provide the desired voltage and pulse shape

  14. Rapidity correlations test stochastic hydrodynamics

    International Nuclear Information System (INIS)

    Zin, C; Gavin, S; Moschelli, G

    2017-01-01

    We show that measurements of the rapidity dependence of transverse momentum correlations can be used to determine the characteristic time τ π that dictates the rate of isotropization of the stress energy tensor, as well as the shear viscosity ν = η/sT . We formulate methods for computing these correlations using second order dissipative hydrodynamics with noise. Current data are consistent with τ π /ν ∼ 10 but targeted measurements can improve this precision. (paper)

  15. An Applied Image Processing for Radiographic Testing

    International Nuclear Information System (INIS)

    Ratchason, Surasak; Tuammee, Sopida; Srisroal Anusara

    2005-10-01

    An applied image processing for radiographic testing (RT) is desirable because it decreases time-consuming, decreases the cost of inspection process that need the experienced workers, and improves the inspection quality. This paper presents the primary study of image processing for RT-films that is the welding-film. The proposed approach to determine the defects on weld-images. The BMP image-files are opened and developed by computer program that using Borland C ++ . The software has five main methods that are Histogram, Contrast Enhancement, Edge Detection, Image Segmentation and Image Restoration. Each the main method has the several sub method that are the selected options. The results showed that the effective software can detect defects and the varied method suit for the different radiographic images. Furthermore, improving images are better when two methods are incorporated

  16. Relation between size of contrast meter and radiographic density difference for radiographic test aluminium welds

    International Nuclear Information System (INIS)

    Senda, Tomio; Hirayama, Kazuo; Masaoka, Naotoshi; Fujita, Minoru.

    1977-01-01

    The influence of contrast meter with difference surface area (5.0 mm x 5.0 mm, 10.0 mm x 10.0 mm, 15.0 mm x 15.0 mm, 30.0 mm x 30.0 mm) and separated type on radiographic density difference (Δ D) were investigated for radiographic test of aluminum welds. It was found that the effect of scattered radiation on contrast meter represented highest at test specimen thickness of 20 mm, and Δ D was constant as the size was increased from 10.0 mm x 10.0 mm to 15.0 mm x 15.0 mm for aluminum contrast meter. For this reason, a proposal of the contrast meter with 10.0 mm x 10.0 mm (surface area) has made to replace (15.0 mm x 15 mm) at amendment of JIS Z 3105. (auth.)

  17. Biodiesel production through hydrodynamic cavitation and performance testing

    Energy Technology Data Exchange (ETDEWEB)

    Pal, Amit; Verma, Ashish; Kachhwaha, S.S.; Maji, S. [Department of Mechanical Engineering, Delhi College of Engineering, Bawana Road, Delhi 110042 (India)

    2010-03-15

    This paper presents the details of development of a biodiesel production test rig based on hydrodynamic cavitation followed by results of experimental investigation carried out on a four cylinder, direct injection water cooled diesel engine operating on diesel and biodiesel blend of Citrullus colocyntis (Thumba) oil. The experiment covers a wide range of engine rpm. Results show that biodiesel of Thumba oil produced through hydrodynamic cavitation technique can be used as an alternative fuel with better performance and lower emissions compared to diesel. The most significant conclusions are that (1) Biodiesel production through hydrodynamic cavitation technique seems to be a simple, efficient, time saving, eco-friendly and industrially viable process. (2) 30% biodiesel blend of Thumba oil shows relatively higher brake power, brake thermal efficiency, reduced bsfc and smoke opacity with favourable p-{theta} diagram as compared to diesel. (author)

  18. Radiographic test phantom for computed tomographic lung nodule analysis

    International Nuclear Information System (INIS)

    Zerhouni, E.A.

    1987-01-01

    This patent describes a method for evaluating a computed tomograph scan of a nodule in a lung of a human or non-human animal. The method comprises generating a computer tomograph of a transverse section of the animal containing lung and nodule tissue, and generating a second computer tomograph of a test phantom comprising a device which simulates the transverse section of the animal. The tissue simulating portions of the device are constructed of materials having radiographic densities substantially identical to those of the corresponding tissue in the simulated transverse section of the animal and have voids therein which simulate, in size and shape, the lung cavities in the transverse section and which contain a test reference nodule constructed of a material of predetermined radiographic density which simulates in size, shape and position within a lung cavity void of the test phantom the nodule in the transverse section of the animal and comparing the respective tomographs

  19. Radiographic testing - optimum radiographs of plastics and composite materials with dosimeter control

    International Nuclear Information System (INIS)

    Kuster, J.

    1978-01-01

    In view of great differencies in X-ray transmission it is more difficult to get optimum radiographs of plastics and especially of reinforced plastics than for example of metals. A procedure will be reported how to get with little effort optimum radiographs especially also in the range of long wavelength radiation corresponding 10 to 25 kV.P. (orig.) [de

  20. Hydrodynamical tests with an original PWR heat removal pump

    International Nuclear Information System (INIS)

    Wietstock, P.

    1984-01-01

    GKSS-Forschungszentrum performes hydrodynamical tests with an original PWR heat removal pump to analyse the influences of fluid parameters on the capacity and cavitation behavior of the pump in order to get further improvements of the quantification of the reached safety-level. It can be concluded, that in case of the tested heat removal pump the additional loads during transition from cavitation free operation into fully cavitation for the investigated operation point with 980 m 3 /h will be smaller than the alteration of loads during passing through the total characteristic. The results from cavitation tests for other operation points indicate, that this very important consequence especially for accident operation will be valid for the total specified pump flow area. (orig.)

  1. Digital radiographic technology; non-destructive testing of tubine blades

    NARCIS (Netherlands)

    Penumadu, P.S.

    2014-01-01

    Inspection of turbine blades has always been a big challenge. Any irregularities in the blade have a huge impact on the gas turbine, so these blades have to be manufactured and inspected in the most sophisticated way possible. The evolution of digital radiographic technology took a leap forward to

  2. Topical issues of radiographic testing and radiation protection. Papers

    International Nuclear Information System (INIS)

    1992-01-01

    The seven papers demonstrate current developments in radiation protection. The amendment of the Radiation Protection Ordinance and the new Ordinance on the Transport of Hazardous Goods by Road were discussed in particular. A major results of the discussion meeting was the foundation of the working group on 'Transport of radioactive substances'. In terms of radiographic practive, the authors addressed European standardization, instruments and technology in radioscopy, and computer-aided image processing. (orig./HP) [de

  3. JIS Z 3105 (methods of radiographic test and classification of radiographs for aluminium welds) and its explanatory note

    International Nuclear Information System (INIS)

    Senda, Tomio

    1977-01-01

    The paragraphs of JIS Z 3105 revised in 1977 are explained, and the problems that were examined by the special committee before the JIS Z 3105 is put in force are reviewed. The JIS Z 3105 consists of a general rule, a method of radiography, a method of classification of the radiographs, and recording. The main problems which were examined are as follows: The radiation penetration testing method of a circumferencial welding portion of a tube was included in the old specifications JIS Z 3105 (1973), but it is excluded in the new specifications, because another specification JIS Z 3108 was established. The gradation meters of D1, D2, D3 and D4 types are added to the gradation meters of the existing A and B types. A restriction in accordance with both focusing dimension and thickness of the welded material is provided between a distance between the focal point and the penetrometer and a distance between the penetrometer and the film. Radiograph concentration of parts other than the penetrometer discrimination and defects of a testing part are specified in accordance with thickness of the base metal. Inclusion of copper and copper oxides are added to the blowholes, the inclusions, cracks, bad penetration and bad fusion as defects for classifying gradation. The gradation of the revised JIS is classified into four grades in lieu of the old three grades. (Iwakiri, K.)

  4. Visual acuity testing of radiographic inspectors in nondestructive inspection. Final report

    International Nuclear Information System (INIS)

    Yonemura, G.T.

    1981-06-01

    Visual acuity tests for radiographic inspectors should be correlated with the type of tasks encountered in real world radiography. The testing procedures should be capable of assessing differences in day to day performance of a given inspector as well as the performance of one inspector relative to other inspectors. Single line targets with specific parametric values for contrast, width, and blur are recommended to provide a means for testing a radiographic inspector for visual acuity. These targets may be used for periodic tests by the employing organization or for more frequent self testing by the inspector. Statistics from the National Health Survey, procedures recommended by the NAS-NRC Committee on Vision and real world radiographs have been utilized in arriving at recommended test configurations

  5. Rippled shock front solutions for testing hydrodynamic stability simulations

    International Nuclear Information System (INIS)

    Munro, D.H.

    1989-01-01

    The response of a shock front to arbitrary small perturbations can be calculated analytically. Such rippled shock front solutions are useful for determining the accuracy of hydrodynamic simulation codes such as LASNEX [Comments Plasma Phys. Controlled Fusion 2, 51 (1977)], which are used to compute perturbation growth in inertial fusion targets. The LASNEX fractional errors are of order κ 2 L 2 , where κ is the transverse wavenumber of the perturbation, and L is the largest zone dimension. Numerical errors are about 25% for a calculation using 26 zones per transverse wavelength

  6. Radiographic testing methods for welds of thin titanium plates and thin wall tubes

    International Nuclear Information System (INIS)

    1984-01-01

    This standard stipulates the testing method by X-ray radiography for the welded parts of titanium plates and titanium tubes with thickness not exceeding 8 mm. The other items than those stipulated here shall be in accordance with JIS Z 3107-1973 ''Testing method by radiography for the welded part of titanium and method of grade classification of radiographs''. As the photographing method of radiographs, the performance of the equipment and materials for testing, the direction of X-ray irradiation, the thickness of parent materials and welds, the use of penetrameters, the arrangement for photographing, the requirement for radiographs and the observation of radiographs are specified. The X-ray apparatuses, photo-sensitive materials and the tools for photographing and observation must be such that the radiographs clearly showing the defects in the welds being tested can be taken or observed. The JIS Z 3107 is insufficient for the test of thin materials like titanium, therefore, this standard was set down. As the thickness of welds, the thickness of parent materials was taken. In this standard, the titanium penetrameters were adopted because they can be made and they conform to practical state. If magnified photographing is carried out with microfocus X-ray apparatuses, precise photographing can be made. (Kako, I.)

  7. Development of a valid and reliable test to assess trauma radiograph interpretation performance

    International Nuclear Information System (INIS)

    Neep, M.J.; Steffens, T.; Riley, V.; Eastgate, P.; McPhail, S.M.

    2017-01-01

    Objectives: The purpose of this investigation was to develop and examine the preliminary validity and reliability among radiographers of a test to assess trauma radiograph interpretation performance suitable for use among health professionals. Methods: Stage 1 examined 14,159 consecutive appendicular and axial examinations from a hospital emergency department over a 12 month period to quantify a typical anatomical region case-mix of trauma radiographs. A sample of radiographic cases representative of affected anatomical regions was then developed into the Image Interpretation Test (IIT). Stage 2 involved prospective investigations of the IIT's reliability (inter-rater, intra-rater, internal consistency) and validity (concurrent) among 41 radiographers. Results: The IIT included 60 cases. The median (interquartile range) clinical experience of participants was 5 (2–10) years. Case scores were internally consistent (Cronbach's alpha = 0.90). Favourable inter-rater reliability (kappa > 0.70 for 58/60 cases, Intra-class correlation coefficient (ICC) > 0.99 for total score) and intra-rater reliability (kappa > 0.90 for 60/60 cases, ICC > 0.99 for total score) was observed. There was a positive association between radiographers' confidence in image interpretation and IIT score (coefficient = 1.52, r-squared = 0.60, p < 0.001). Conclusions: The IIT developed during this investigation included a selection of radiographic cases consistent with anatomical regions represented in an adult trauma case-mix. This study has also provided foundational preliminary evidence to support the reliability and validity of the IIT among radiographers. The findings suggest that it is possible to assess image interpretation performance of adult trauma radiographs with this test. - Highlights: • Development of an Image Interpretation Test (IIT). • Cases consistent with anatomical regions represented in a typical adult trauma case-mix. • Development of a

  8. A critical test of bivelocity hydrodynamics for mixtures.

    Science.gov (United States)

    Brenner, Howard

    2010-10-21

    The present paper provides direct noncircumstantial evidence in support of the existence of a diffuse flux of volume j(v) in mixtures. As such, it supersedes an earlier paper [H. Brenner, J. Chem. Phys. 132, 054106 (2010)], which offered only indirect circumstantial evidence in this regard. Given the relationship of the diffuse volume flux to the fluid's volume velocity, this finding adds additional credibility to the theory of bivelocity hydrodynamics for both gaseous and liquid continua, wherein the term bivelocity refers to the independence of the fluid's respective mass and volume velocities. Explicitly, the present work provides a new and unexpected linkage between a pair of diffuse fluxes entering into bivelocity mixture theory, fluxes that were previously regarded as constitutively independent, except possibly for their coupling arising as a consequence of Onsager reciprocity. In particular, for the case of a binary mixture undergoing an isobaric, isothermal, external force-free, molecular diffusion process we establish by purely macroscopic arguments-while subsequently confirming by purely molecular arguments-the validity of the ansatz j(v)=(v(1)-v(2))j(1) relating the diffuse volume flux j(v) to the diffuse mass fluxes j(1)(=-j(2)) of the two species and, jointly, their partial specific volumes v(1),v(2). Confirmation of that relation is based upon the use of linear irreversible thermodynamic principles to embed this ansatz in a broader context, and to subsequently establish the accord thereof with Shchavaliev's solution of the multicomponent Boltzmann equation for dilute gases [M. Sh. Shchavaliev, Fluid Dyn. 9, 96 (1974)]. Moreover, because the terms v(1), v(2), and j(1) appearing on the right-hand side of the ansatz are all conventional continuum fluid-mechanical terms (with j(1) given, for example, by Fick's law for thermodynamically ideal solutions), parity requires that j(v) appearing on the left-hand side of that relation also be a continuum term

  9. An apparatus to estimate the hydrodynamic coefficients of autonomous underwater vehicles using water tunnel testing.

    Science.gov (United States)

    Nouri, N M; Mostafapour, K; Bahadori, R

    2016-06-01

    Hydrodynamic coefficients or hydrodynamic derivatives of autonomous underwater vehicles (AUVs) play an important role in their development and maneuverability. The most popular way of estimating their coefficients is to implement captive model tests such as straight line tests and planar motion mechanism (PMM) tests in the towing tanks. This paper aims to develop an apparatus based on planar experiments of water tunnel in order to estimate hydrodynamic derivatives due to AUVs' acceleration and velocity. The capability of implementing straight line tests and PMM ones using mechanical oscillators located in the downstream flow of the model is considered in the design procedure of the system. The hydrodynamic derivatives that resulted from the acceleration and velocity of the AUV model were estimated using the apparatus that we developed. Static and dynamics test results were compared for the similar derivatives. The findings showed that the system provided the basis for conducting static tests, i.e., straight-line and dynamic tests that included pure pitch and pure heave. By conducting such tests in a water tunnel, we were able to eliminate errors related to the time limitation of the tests and the effects of surface waves in the towing tank on AUVs with applications in the deep sea.

  10. Yield and Depth of Burial Hydrodynamic Calculations in Granodiorite: Implications for the North Korean Test Site

    Science.gov (United States)

    2011-09-01

    the existence of a test site body wave magnitude (mb) bias between U. S. and the former Soviet Union test sites in Nevada and Semipalatinsk . The use...YIELD AND DEPTH OF BURIAL HYDRODYNAMIC CALCULATIONS IN GRANODIORITE:IMPLICATIONS FOR THE NORTH KOREAN TEST SITE Esteban Rougier, Christopher R...Korean test site and the May 2009 test . When compared to the Denny and Johnson (1991) and to the Heard and Ackerman (1967) cavity radius scaling models

  11. Contribution to the study for an optimum choice of filter and screens in radiographic testing

    International Nuclear Information System (INIS)

    Caillieret, V.; Peix, G.; Babot, D.; Lormand, G.

    1985-01-01

    In order to optimize the choices of screens and filter in steel specimens radiographic testing with iridium 192 and cobalt 60, we started a theoretical and experimental study of their actions on radiative and latent images formation. Theoretical modelisation of photons interactions in steel and experimental apparatus for spectral analysis are described

  12. Study of the sensitivity of wire image quality indicators (IQI) used in radiographic testing of metals and alloys

    International Nuclear Information System (INIS)

    Sanchez, W.; Oki, H.

    1974-01-01

    Radiographic sensitivity is defined and its mathematical expresion is derived in order to justify the use of image quality indicators-IQI- formed by wires of different diameters which represent the radiographic quality. It is demonstrated that IQI sensibility is not related to the minimum dimensions of the metallic discontinuities that may be detected in radiographic tests. The experimental results are in good agreement whith the mathematical formulation proposed

  13. The impact of image test bank construction on radiographic interpretation outcomes: A comparison study

    International Nuclear Information System (INIS)

    Hardy, M.; Flintham, K.; Snaith, B.; Lewis, E.F.

    2016-01-01

    Introduction: Assessment of image interpretation competency is commonly undertaken through review of a defined image test bank. Content of these image banks has been criticised for the high percentage of abnormal examinations which contrasts with lower reported incidences of abnormal radiographs in clinical practice. As a result, questions have been raised regarding the influence of prevalence bias on the accuracy of interpretive decision making. This article describes a new and novel approach to the design of musculoskeletal image test banks. Methods: Three manufactured image banks were compiled following a standard academic menu in keeping with previous studies. Three further image test banks were constructed to reflect local clinical workload within a single NHS Trust. Eighteen radiographers, blinded to the method of test bank composition, were randomly assigned 2 test banks to review (1 manufactured, 1 clinical workload). Comparison of interpretive accuracy was undertaken. Results: Inter-rater agreement was moderate to good for all image banks (manufactured: range k = 0.45–0.68; clinical workload: k = 0.49–0.62). A significant difference in mean radiographer sensitivity was noted between test bank designs (manufactured 87.1%; clinical workload 78.5%; p = 0.040, 95% CI = 0.4–16.8; t = 2.223). Relative parity in radiographer specificity and overall accuracy was observed. Conclusion: This study confirms the findings of previous research that high abnormality prevalence image banks over-estimate the ability of observers to identify abnormalities. Assessment of interpretive competency using an image bank that reflects local clinical practice is a better approach to accurately establish interpretive competency and the learning development needs of individual practitioners. - Highlights: • High prevalence image test banks over-estimate the ability of observers. • Clinical workload test banks may better reflect image interpretation competency.

  14. Radiographic and ultrasonic testings of welded joints of 6063 aluminium alloy

    International Nuclear Information System (INIS)

    Oliveira e Silva Mury, A.G. de.

    1980-05-01

    A study on evaluation of weld defects in aluminium butt joints was made in a comparative way through the radiographic and ultrasonic testing. This work was conducted with pipes 5 IPS (6,35 mm thickness) of 6063 aluminium alloy, circumferential TIG welded, due to the difficulty on performing non-destructive testing with this schedule. It was concluded thta ultrasonic testing has adequate sensitivity when setting gain adjustment is made with aid of a reference curve constructed by using a Reference Block (among others studied) with 1,5 mm dia. Hole as reference reflector, and a 5 MHz angle beam search-unit. In this case the ultrasonic testing is more accurate than radiographic testing to detect planar defects like lack of fusion and lack of penetration. Defect sizing by ultrasonic methods employed were 6 and 20 dB drop methods. In spite of your observed limitations concerning the establishment of the real size of defects, the procedure applied was precise for locate and define the weld defects that where found in this study. (author) [pt

  15. Neutron radiographic testing of samples of special concrete containing recycled PET granules as aggregate

    International Nuclear Information System (INIS)

    Moraes, Antonio Carlos Alves de; Crispim, Verginia Reis

    2011-01-01

    This study aimed at inspecting microcracks in test specimens of special concrete, through neutron radiography tests. The thermal neutron flux used was extracted from the J-9 irradiation channel, placed in the thermal column of Argonauta/IEN/CNEN/RJ reactor, where a neutron radiographic system is installed. The test specimens inspected were molded in a cylindrical shape, with standard concrete and modified concrete where coarse sand was substituted by granules of recycled PET. They were submitted to compression in a SHIMADSU UH F 1000 press, causing microcracks. Then, slices of 50 μm thickness were obtained using an electrical saw. Gadolinium nitrate was used as contrast liquid in order to enhance the visualization of those microcracks. The Neutron Radiography technique proved to be appropriate for this kind of inspection, allowing to clearly visualizing the microcracks. Recycled PET granules met ABNT standards, and may be used in the construction of low income people houses, as structural concrete (25 % PP) or house floors (25% to 50% PEAD). The mechanical properties of compression and elasticity demonstrated for this special concrete, on Civil Engineering conventional tests, and by the neutron radiographic images obtained, showed that its use is viable even for civil construction in areas subject to seismic vents. (author)

  16. Development and testing of texture discriminators for the analysis of trabecular bone in proximal femur radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Huber, M. B.; Carballido-Gamio, J.; Fritscher, K.; Schubert, R.; Haenni, M.; Hengg, C.; Majumdar, S.; Link, T. M. [Department of Radiology and Biomedical Imaging, University of California, 400 Parnassus Avenue, San Francisco, California 94143 (United States); University of Health Sciences, Medical Informatics and Technology, 6060 Hall (Austria); AO Development Institute, 7270 Davos Platz (Switzerland); Medical University Innsbruck, 6020 Innsbruck (Austria); Department of Radiology and Biomedical Imaging, University of California, 400 Parnassus Avenue, San Francisco, California 94143 (United States)

    2009-11-15

    Purpose: Texture analysis of femur radiographs may serve as a potential low cost technique to predict osteoporotic fracture risk and has received considerable attention in the past years. A further application of this technique may be the measurement of the quality of specific bone compartments to provide useful information for treatment of bone fractures. Two challenges of texture analysis are the selection of the best suitable texture measure and reproducible placement of regions of interest (ROIs). The goal of this in vitro study was to automatically place ROIs in radiographs of proximal femur specimens and to calculate correlations between various different texture analysis methods and the femurs' anchorage strength. Methods: Radiographs were obtained from 14 femoral specimens and bone mineral density (BMD) was measured in the femoral neck. Biomechanical testing was performed to assess the anchorage strength in terms of failure load, breakaway torque, and number of cycles. Images were segmented using a framework that is based on the usage of level sets and statistical in-shape models. Five ROIs were automatically placed in the head, upper and lower neck, trochanteric, and shaft compartment in an atlas subject. All other subjects were registered rigidly, affinely, and nonlinearly, and the resulting transformation was used to map the five ROIs onto the individual femora. Results: In each ROI, texture features were extracted using gray level co-occurence matrices (GLCM), third-order GLCM, morphological gradients (MGs), Minkowski dimensions (MDs), Minkowski functionals (MFs), Gaussian Markov random fields, and scaling index method (SIM). Coefficients of determination for each texture feature with parameters of anchorage strength were computed. In a stepwise multiregression analysis, the most predictive parameters were identified in different models. Texture features were highly correlated with anchorage strength estimated by the failure load of up to R{sup 2

  17. Development and testing of texture discriminators for the analysis of trabecular bone in proximal femur radiographs

    International Nuclear Information System (INIS)

    Huber, M. B.; Carballido-Gamio, J.; Fritscher, K.; Schubert, R.; Haenni, M.; Hengg, C.; Majumdar, S.; Link, T. M.

    2009-01-01

    Purpose: Texture analysis of femur radiographs may serve as a potential low cost technique to predict osteoporotic fracture risk and has received considerable attention in the past years. A further application of this technique may be the measurement of the quality of specific bone compartments to provide useful information for treatment of bone fractures. Two challenges of texture analysis are the selection of the best suitable texture measure and reproducible placement of regions of interest (ROIs). The goal of this in vitro study was to automatically place ROIs in radiographs of proximal femur specimens and to calculate correlations between various different texture analysis methods and the femurs' anchorage strength. Methods: Radiographs were obtained from 14 femoral specimens and bone mineral density (BMD) was measured in the femoral neck. Biomechanical testing was performed to assess the anchorage strength in terms of failure load, breakaway torque, and number of cycles. Images were segmented using a framework that is based on the usage of level sets and statistical in-shape models. Five ROIs were automatically placed in the head, upper and lower neck, trochanteric, and shaft compartment in an atlas subject. All other subjects were registered rigidly, affinely, and nonlinearly, and the resulting transformation was used to map the five ROIs onto the individual femora. Results: In each ROI, texture features were extracted using gray level co-occurence matrices (GLCM), third-order GLCM, morphological gradients (MGs), Minkowski dimensions (MDs), Minkowski functionals (MFs), Gaussian Markov random fields, and scaling index method (SIM). Coefficients of determination for each texture feature with parameters of anchorage strength were computed. In a stepwise multiregression analysis, the most predictive parameters were identified in different models. Texture features were highly correlated with anchorage strength estimated by the failure load of up to R 2 =0.61 (MF

  18. Research reactor fuel bundle design review by means of hydrodynamic testing

    International Nuclear Information System (INIS)

    Pastorini, A.; Belinco, C.

    1997-01-01

    During the design steps of a fuel bundle for a nuclear reactor, some vibration tests are usually necessary to verify the prototype dynamical response characteristics and the structural integrity. To perform these tests, the known hydrodynamic loop facilities are used to evaluate the vibrational response of the bundle under the different flow conditions that may appear in the reactor. This paper describes the tests performed on a 19 plate fuel bundle prototype designed for a low power research reactor. The tests were done in order to know the dynamical characteristics of the plates and also of the whole bundle under different flow rate conditions. The paper includes a description of the test facilities and the results obtained during the dynamical characterization tests and some preliminary comments about the tests under flowing water are also presented. (author) [es

  19. Estimated accuracy of classification of defects detected in welded joints by radiographic tests

    International Nuclear Information System (INIS)

    Siqueira, M.H.S.; De Silva, R.R.; De Souza, M.P.V.; Rebello, J.M.A.; Caloba, L.P.; Mery, D.

    2004-01-01

    This work is a study to estimate the accuracy of classification of the main classes of weld defects detected by radiography test, such as: undercut, lack of penetration, porosity, slag inclusion, crack or lack of fusion. To carry out this work non-linear pattern classifiers were developed, using neural networks, and the largest number of radiographic patterns as possible was used as well as statistical inference techniques of random selection of samples with and without repositioning (bootstrap) in order to estimate the accuracy of the classification. The results pointed to an estimated accuracy of around 80% for the classes of defects analyzed. (author)

  20. Estimated accuracy of classification of defects detected in welded joints by radiographic tests

    Energy Technology Data Exchange (ETDEWEB)

    Siqueira, M.H.S.; De Silva, R.R.; De Souza, M.P.V.; Rebello, J.M.A. [Federal Univ. of Rio de Janeiro, Dept., of Metallurgical and Materials Engineering, Rio de Janeiro (Brazil); Caloba, L.P. [Federal Univ. of Rio de Janeiro, Dept., of Electrical Engineering, Rio de Janeiro (Brazil); Mery, D. [Pontificia Unversidad Catolica de Chile, Escuela de Ingenieria - DCC, Dept. de Ciencia de la Computacion, Casilla, Santiago (Chile)

    2004-07-01

    This work is a study to estimate the accuracy of classification of the main classes of weld defects detected by radiography test, such as: undercut, lack of penetration, porosity, slag inclusion, crack or lack of fusion. To carry out this work non-linear pattern classifiers were developed, using neural networks, and the largest number of radiographic patterns as possible was used as well as statistical inference techniques of random selection of samples with and without repositioning (bootstrap) in order to estimate the accuracy of the classification. The results pointed to an estimated accuracy of around 80% for the classes of defects analyzed. (author)

  1. Estimation of radiation dose received by the radiation workers during radiographic testing

    International Nuclear Information System (INIS)

    Mohammed, N. A. H. O.

    2013-08-01

    This study was conducted primarily to evaluate occupational radiation dose in industrial radiography during radiographic testing at Balil-Hadida, with the aim of building up baseline data on radiation exposure in the industrial radiography practice in Sudan. Dose measurements during radiographic testing were performed and compared with IAEA reference dose. In this research the doses measured by using hand held radiation survey meter and personal monitoring dosimeter. The results showed that radiation doses ranged between minimum (0.448 mSv/ 3 month) , and maximum (1.838 mSv / 3 month), with an average value (0.778 mSv/ 3 month), and the standard deviation 0.292 for the workers used gamma mat camera. The analysis of data showed that the radiation dose for all radiation worker are receives less than annual limit for exposed workers 20 mSv/ year and compare with other study found that the dose received while body doses ranging from 0.1 to 9.4 mSv/ year, work area design in all the radiography site followed the three standard rules namely putting radiation signs, reducing access to control area and making of boundaries. Thus the accidents arising from design faults not likely to occur at these site. Results suggest that adequate fundamental training of radiation workers in general radiography prior to industrial radiography work will further improve the standard of personnel radiation protection. (Author)

  2. Computer-assisted radiographic testing for objective quality assurance of castings

    International Nuclear Information System (INIS)

    Klatte, R.

    1985-01-01

    This study is concerned with the application of digital image processing for the automatic evaluation of radiographs in material testing. It was the special aim of research to develop automatic image evaluation processes for series examination of light metal castings. The description of the problem is based on the properties of the image transmitting system Various methods for the detection of casting defects are presented and discussed. A detailed description is given of the development of a method for detecting casting defects characterized by the features of dendritic-porous-small. By generating a reference image from the test image, the method is made insensitive towards intensity fluctuations, casting tolerances and positioning errors. Then, the method was implemented into an image processing system together with the required filter (KANTROP) and the classification algorithms. The cycle times required for industrial use have also been considered. The program system for automatic testing is presented. (orig./HP) [de

  3. Potentialities of fluorography in radiographic testing of nuclear power plant equipment

    International Nuclear Information System (INIS)

    Gromov, Yu.V.; Kapustin, V.I.

    1984-01-01

    Results of fluorography of steel 5-250 mm thick with the application of different radiation sources in accordance with existing test requirements and standards for NPP equipment under industrial conditions, are presented. Sensitivity curves of fluorographic and radiographic testing methods using the RUP-150/300-10 X-ray device, LUEh-15-15000 D linear accelerator flaw detectors with 192 Yr, 60 Co, 137 Cs sources, are given. The radiation energy range is 24O keV-8 MeV. It is shown that fluorographic method meets the requirements of sensitivity and is recommended to test welded joints 5-220 mm thick in NPP equipment under laboratory and industrial conditions

  4. Animal radiographs

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    This chapter presents historical x rays of a wide variety of animals taken within 5 years of the discovery of x radiation. Such photos were used as tests or as illustrations for radiographic publications. Numerous historical photographs are included. 10 refs

  5. Porosity. ''The good, the bad and ugly'' of Radiographic Testing

    International Nuclear Information System (INIS)

    Vaughan, Hugo

    2016-01-01

    ''Radiographic Testing is a NDT method to detect inherent volumetric discontinuities in materials such as castings and welds'' A common type of discontinuity found and most often misinterpreted and evaluated is rounded indications, whether isolated, aligned or clustered. This paper addresses the acceptance criteria of rounded indications based on various codes and standards and intends to lay at rest the confusion related to this type of discontinuity. The following are important considerations: 1. Interpretation of rounded indications based on codes and standards used in the various sectors of NDT. 2. What types of discontinuities can be regarded as rounded indications? 3. What discontinuity sizes can be regarded as relevant discontinuities? 4. What are the acceptance and rejection criteria for relevant rounded indications 5. Compiling relevant student assignments to facilitate the proper understanding of this aspect.

  6. MRI studies of the hydrodynamics in a USP 4 dissolution testing cell.

    Science.gov (United States)

    Shiko, G; Gladden, L F; Sederman, A J; Connolly, P C; Butler, J M

    2011-03-01

    We present a detailed study of hydrodynamics inside the flow-through dissolution apparatus when operated according to USP recommendations. The pulsatile flow inside the flow-through cell was measured quantitatively using magnetic resonance imaging (MRI) at a spatial resolution of 234 × 234 μm(2) and slice thickness of 1 mm. We report the experimental protocols developed for in situ MRI studies and the effect that the operating conditions and tablet orientation have on the hydrodynamics inside commercial flow cells. It was found that the flow field inside the dissolution cells was, at most operating conditions, heterogeneous, rather than fully developed laminar flow, and characterised by re-circulation and backward flow. A model tablet was shown to be contacted by a wide distribution of local velocities as a function of position and orientation in the flow cell. The use of 1 mm beads acted as a distributor of the flow but did not suffice to ensure a fully developed laminar flow profile. These results emphasise the necessity to understand the influence of test conditions on dissolution behaviour in defining robust flow-through dissolution methods. Copyright © 2010 Wiley-Liss, Inc.

  7. Coupled hydrodynamic-structural analysis of an integral flowing sodium test loop in the TREAT reactor

    International Nuclear Information System (INIS)

    Zeuch, W.R.; A-Moneim, M.T.

    1979-01-01

    A hydrodynamic-structural response analysis of the Mark-IICB loop was performed for the TREAT (Transient Reactor Test Facility) test AX-1. Test AX-1 is intended to provide information concerning the potential for a vapor explosion in an advanced-fueled LMFBR. The test will be conducted in TREAT with unirradiated uranium-carbide fuel pins in the Mark-IICB integral flowing sodium loop. Our analysis addressed the ability of the experimental hardware to maintain its containment integrity during the reference accident postulated for the test. Based on a thermal-hydraulics analysis and assumptions for fuel-coolant interaction in the test section, a pressure pulse of 144 MPa maximum pressure and pulse width of 1.32 ms has been calculated as the reference accident. The response of the test loop to the pressure transient was obtained with the ICEPEL and STRAW codes. Modelling of the test section was completed with STRAW and the remainder of the loop was modelled by ICEPEL

  8. Investigation of the hydrodynamic model test of forced rolling for a barge using PIV

    Directory of Open Access Journals (Sweden)

    WANG Xiaoqiang

    2017-03-01

    Full Text Available In order to study the physical details of viscous flow in ship roll motions and improve the accuracy of ship roll damping numerical simulation, the application of the Particle Image Velocimetry (PIV technique is investigated in model tests of forced ship rolling in calm water. The hydrodynamic force and flow field at the bilge region are simultaneously measured for barges at different amplitudes and frequencies in which the self-made forced rolling facility was used. In the model test, the viscous flow variation with the time around the bilge region was studied during ship rolling motion. The changes in ship roll damping coefficients with the rolling amplitude and period were also investigated. A comparison of the model test results with the Computational Fluid Dynamics(CFDresults shows that the numerical ship roll damping coefficients agree well with the model test results, while the differences in the local flow details exist between the CFD results and model test results. Further research into the model test technique and CFD application is required.

  9. Hydraulic and hydrodynamic tests for design evaluation of research reactors fuel elements

    International Nuclear Information System (INIS)

    Kulichevsky, R.; Martin Ghiselli, A.; Fiori, J.; Yedros, P.

    2002-01-01

    During the design steps of research reactors fuel elements some tests are usually necessary to verify its design, i.e.: its hydraulic characteristics, dynamical response and structural integrity. The hydraulic tests are developed in order to know the pressure drops characteristics of different parts or elements of the prototype and of the whole fuel element. Also, some tests are carried out to obtain the velocity distribution of the coolant water across different prototype's sections. The hydrodynamic tests scopes are the assessment of the dynamical characteristics of the fuel elements and their components and its dynamical response considering the forces generated by the coolant flowing water at different flow rate conditions. Endurance tests are also necessary to qualify the structural design of the FE prototypes and their corresponding clamp tools, verifying the whole system structural integrity and wear processes influences. To carry out these tests a special test facility is needed to obtain a proper representation of the hydraulic and geometric boundary conditions of the fuel element. In some cases changes on the fuel element prototype or dummy are necessary to assure that the data results are representative of the case under study. Different kind of sensors are mounted on the test section and also on the fuel element itself when necessary. Some examples of the instrumentation used are strain gauges, displacement transducers, absolute and differential pressure transducers, pitot tubes, etc. The obtained data are, for example, plates' vibration amplitudes and frequencies, whole bundle displacement characterization, pressure drops and flow velocity measurements. The Experimental Low Pressure Loop is a hydraulic loop located at CNEA's Constituyentes Atomic Center and is the test facility where different kind of tests are performed in order to support and evaluate the design of research reactor fuel elements. A brief description of the facility, and examples of

  10. Dynamic Stress Testing Is Unnecessary for Unimalleolar Supination-External Rotation Ankle Fractures with Minimal Fracture Displacement on Lateral Radiographs.

    Science.gov (United States)

    Nortunen, Simo; Leskelä, Hannu-Ville; Haapasalo, Heidi; Flinkkilä, Tapio; Ohtonen, Pasi; Pakarinen, Harri

    2017-03-15

    This study aimed to identify factors from standard radiographs that contributed to the stability of the ankle mortise in patients with isolated supination-external rotation fractures of the lateral malleolus (OTA/AO 44-B). Non-stress radiographs of the mortise and lateral views, without medial clear space widening or incongruity, were prospectively collected for 286 consecutive patients (mean age, 45 years [range, 16 to 85 years]), including 144 female patients (mean age, 50 years [range, 17 to 85 years]) and 142 male patients (mean age, 40 years [range, 16 to 84 years]) from 2 trauma centers. The radiographs were analyzed for fracture morphology by 2 orthopaedic surgeons, who were blinded to each other's measurements and to the results of external rotation stress radiographs (the reference for stability). Factors significantly associated with ankle mortise stability were tested in multiple logistic regression. Receiver operating characteristic analyses were performed for continuous variables to determine optimal thresholds. A sensitivity of >90% was used as the criterion for an optimal threshold. According to external rotation stress radiographs, 217 patients (75.9%) had a stable injury, defined as that with a medial clear space of ankle mortise were female sex (odds ratio [OR], 2.5 [95% confidence interval (CI), 1.4 to 4.6]), a posterior diastasis of fracture fragments (OR, 7.3 [95% CI, 2.1 to 26.3]). When the posterior diastasis was fracture fragments were present, the probability of a stable ankle mortise was 0.98 for 48 female patients (16.8%) and 0.94 for 37 male patients (12.9%). Patients with noncomminuted lateral malleolar fractures (85 patients [29.7%]) could be diagnosed with a stable ankle mortise without further stress testing, when the fracture line widths were <2 mm on lateral radiographs. Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  11. Coupling Hydrodynamic and Wave Propagation Codes for Modeling of Seismic Waves recorded at the SPE Test.

    Science.gov (United States)

    Larmat, C. S.; Rougier, E.; Delorey, A.; Steedman, D. W.; Bradley, C. R.

    2016-12-01

    The goal of the Source Physics Experiment (SPE) is to bring empirical and theoretical advances to the problem of detection and identification of underground nuclear explosions. For this, the SPE program includes a strong modeling effort based on first principles calculations with the challenge to capture both the source and near-source processes and those taking place later in time as seismic waves propagate within complex 3D geologic environments. In this paper, we report on results of modeling that uses hydrodynamic simulation codes (Abaqus and CASH) coupled with a 3D full waveform propagation code, SPECFEM3D. For modeling the near source region, we employ a fully-coupled Euler-Lagrange (CEL) modeling capability with a new continuum-based visco-plastic fracture model for simulation of damage processes, called AZ_Frac. These capabilities produce high-fidelity models of various factors believed to be key in the generation of seismic waves: the explosion dynamics, a weak grout-filled borehole, the surrounding jointed rock, and damage creation and deformations happening around the source and the free surface. SPECFEM3D, based on the Spectral Element Method (SEM) is a direct numerical method for full wave modeling with mathematical accuracy. The coupling interface consists of a series of grid points of the SEM mesh situated inside of the hydrodynamic code's domain. Displacement time series at these points are computed using output data from CASH or Abaqus (by interpolation if needed) and fed into the time marching scheme of SPECFEM3D. We will present validation tests with the Sharpe's model and comparisons of waveforms modeled with Rg waves (2-8Hz) that were recorded up to 2 km for SPE. We especially show effects of the local topography, velocity structure and spallation. Our models predict smaller amplitudes of Rg waves for the first five SPE shots compared to pure elastic models such as Denny &Johnson (1991).

  12. Electrochemical Genotoxicity Assay Based on a SOS/umu Test Using Hydrodynamic Voltammetry in a Droplet

    Science.gov (United States)

    Kuramitz, Hideki; Sazawa, Kazuto; Nanayama, Yasuaki; Hata, Noriko; Taguchi, Shigeru; Sugawara, Kazuharu; Fukushima, Masami

    2012-01-01

    The SOS/umu genotoxicity assay evaluates the primary DNA damage caused by chemicals from the β-galactosidase activity of S. typhimurium. One of the weaknesses of the common umu test system based on spectrophotometric detection is that it is unable to measure samples containing a high concentration of colored dissolved organic matters, sediment, and suspended solids. However, umu tests with electrochemical detection techniques prove to be a better strategy because it causes less interference, enables the analysis of turbid samples and allows detection even in small volumes without loss of sensitivity. Based on this understanding, we aim to develop a new umu test system with hydrodynamic chronoamperometry using a rotating disk electrode (RDE) in a microliter droplet. PAPG when used as a substrate is not electroactive at the potential at which PAP is oxidized to p-quinone imine (PQI), so the current response of chronoamperometry resulting from the oxidation of PAP to PQI is directly proportional to the enzymatic activity of S. typhimurium. This was achieved by performing genotoxicity tests for 2-(2-furyl)-3-(5-nitro-2-furyl)-acrylamide (AF-2) and 2-aminoanthracene (2-AA) as model genotoxic compounds. The results obtained in this study indicated that the signal detection in the genotoxicity assay based on hydrodynamic voltammetry was less influenced by the presence of colored components and sediment particles in the samples when compared to the usual colorimetric signal detection. The influence caused by the presence of humic acids (HAs) and artificial sediment on the genotoxic property of selected model compounds such as 4-nitroquinoline-N-oxide (4-NQO), 3-chloro-4-(dichloromethyl)-5-hydroxy-2(5H)-furanone (MX), 1,8-dinitropyrene (1,8-DNP) and 1-nitropyrene (1-NP) were also investigated. The results showed that the genotoxicity of 1-NP and MX changed in the presence of 10 mg·L−1 HAs. The genotoxicity of tested chemicals with a high hydrophobicity such as 1,8-DNP

  13. Banki-Michell Optimal Design by Computational Fluid Dynamics Testing and Hydrodynamic Analysis

    Directory of Open Access Journals (Sweden)

    Tullio Tucciarelli

    2013-04-01

    Full Text Available In hydropower, the exploitation of small power sources requires the use of small turbines that combine efficiency and economy. Banki-Michell turbines represent a possible choice for their simplicity and for their good efficiency under variable load conditions. Several experimental and numerical tests have already been designed for examining the best geometry and optimal design of cross-flow type machines, but a theoretical framework for a sequential design of the turbine parameters, taking full advantage of recently expanded computational capabilities, is still missing. To this aim, after a review of the available criteria for Banki-Michell parameter design, a novel two-step procedure is described. In the first step, the initial and final blade angles, the outer impeller diameter and the shape of the nozzle are selected using a simple hydrodynamic analysis, based on a very strong simplification of reality. In the second step, the inner diameter, as well as the number of blades and their shape, are selected by testing single options using computational fluid dynamics (CFD simulations, starting from the suggested literature values. Good efficiency is attained not only for the design discharge, but also for a large range of variability around the design value.

  14. Radiographic constant exposure technique

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1985-01-01

    The constant exposure technique has been applied to assess various industrial radiographic systems. Different X-ray films and radiographic papers of two producers were compared. Special attention was given to fast film and paper used with fluorometallic screens. Radiographic image quality...... was tested by the use of ISO wire IQI's and ASTM penetrameters used on Al and Fe test plates. Relative speed and reduction of kilovoltage obtained with the constant exposure technique were calculated. The advantages of fast radiographic systems are pointed out...

  15. Utilization of radiographic and ultrasonic testing for an evaluation of plate type fuel elements during manufacturing stages

    International Nuclear Information System (INIS)

    Brito, Mucio Jose Drummond de; Silva Junior, Silverio Ferreira da; Messias, Jose Marcos; Braga, Daniel Martins; Paula, Joao Bosco de

    2005-01-01

    Structural discontinuities can be introduced in the plate type fuel elements during the manufacturing stages due to mechanical processing conditions. The use of nondestructive testing methods to monitoring the fuel elements during the manufacturing stages presents a significant importance, contributing for manufacturing process improvement and cost reducing. This paper describes a procedure to be used detection and evaluation of structural discontinuities in plate type fuel elements during the manufacturing stages using the ultrasonic testing method and the radiographic testing method. The main results obtained are presented and discussed. (author)

  16. Hydrodynamic and mechanical tests of a newly improved counter-current multi-stage centrifugal extractor

    International Nuclear Information System (INIS)

    Ionita, Gheorghe; Mirica, Dumitru; Croitoru, Cornelia; Stefanescu, Ioan; Retegan, Teodora

    2003-01-01

    Total actinide recovery, lanthanide/actinide separation and the selective partitioning of actinide from high level waste (HLW) are nowadays of major interest. Actinide partitioning with a view to safe disposing of HLW or utilization in many other applications of recovered elements involves an extraction process usually carried out by means of a mixer-settler, pulse column or centrifugal contactor. This last, presents some doubtless advantages and responds to the above mentioned goals. A new type of counter-current multistage centrifugal extractor has been designed and built. Similar apparatus was not found in the literature published to-date. The counter-current multi-stage centrifugal extractor is a stainless steel cylinder with an effective length of 346 mm, the effective diameter of 100 mm and a volume of 1.5 liters, working in horizontal position. The new internal structure and geometry of the new advanced centrifugal extractor consisting of nine cells (units), five rotation units, two mixing units, two propelling units and two final plates, ensures the counter-current running of the two phases.The central shaft having the rotation cells fixed on it is coupled by an intermediary connection to a electric motor of high rotation speed. Conceptual layout of the advanced counter-current multi-stage centrifugal extractor is presented. The newly designed extractor has been tested at 1000-3000 rot/min for a ratio of the aqueous/organic phase =1 to examine the mechanical behavior and the hydrodynamics of the two phases in countercurrent. The results showed that the performances have been generally good and the design requirements were fulfilled. The newly designed counter-current multistage centrifugal extractor appears to be a promising way to increase extraction rate of radionuclides and metals from liquid effluents. (authors)

  17. Fast radiographic systems

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1984-08-01

    Industrial radiography can be performed with shorter exposure times, when instead of X-ray film with lead intensifying screens the radiographic paper with fluorescent screen is used. With paper radiography one can obtain lower material, equipment, and labor costs, shorter exposure and processing times, and easier radiation protection. The speed of the radiographic inspection can also be increased by the use of fluorometallic intensifying screens together with a special brand of X-ray film. Before accepting either of the two fast radiographic systems one must be sure that they can produce radiographs of adequate image quality. Therefore an investigation was performed on that subject using ISO wire IQI's and ASTM penetrameters. The radiographic image quality was tested for aluminium and steel up to 30 mm thick using various brands of radiographic paper and X-ray film with fluorometallic screens and comparing them with fast X-ray films with lead screens. Both systems give satisfactory results. (author)

  18. Radiographic evaluations

    International Nuclear Information System (INIS)

    Williams, J.L.

    1988-01-01

    The author describes how to: perform a systematic evaluation of a chest radiograph; state the classic radiographic description of hyaline membrane disease; list the conditions that cause hyperaeration and describe the radiologic feature of hyperaeration; describe the radiograph of a patient with a congenital diaphragmatic hernia; identify optimum placement of an endotracheal tube, gastric feeding tube, and umbilical artery catheter on a radiograph; differentiate between pulmonary interstitial air and hyaline membrane disease; select radiographic features that would indicate the presence of a tension pneumothorax; describe a lateral decubitus projection and state the type of problem it is most often used to identify; explain the procedure used in obtaining a lateral neck radiograph and list two problems that may require this view; and describe the radiograph of a patient with cystic fibrosis

  19. Impact analysis and testing of tritiated heavy water transportation packages including hydrodynamic effects

    International Nuclear Information System (INIS)

    Sauve, R.G.; Tulk, J.D.; Gavin, M.E.

    1989-01-01

    Ontario Hydro has recently designed a new Type B(M) Tritiated Heavy Water Transportation Package (THWTP) for the road transportation of tritiated heavy water from its operating nuclear stations to the Tritium Removal Facility in Ontario. These packages must demonstrate the ability to withstand severe shock and impact scenarios such as those prescribed by IAEA standards. The package, shown in figure 1, comprises an inner container filled with tritiated heavy water, and a 19 lb/ft 3 polyurethane foam-filled overpack. The overpack is of sandwich construction with 304L stainless steel liners and 10.5 inch thick nominal foam walls. The outer shell is 0.75 inch thick and the inner shell is 0.25 inch thick. The primary containment boundary consists of the overpack inner liner, the containment lid and outer containment seals in the lid region. The total weight of the container including the 12,000 lb. payload is 36,700 lb. The objective of the present study is to evaluate the hydrodynamic effect of the tritiated heavy water payload on the structural integrity of the THWTP during a flat end drop from a height of 9 m. The study consisted of three phases: (i) developing an analytical model to simulate the hydrodynamic effects of the heavy water payload during impact; (ii) performing an impact analysis for a 9 m flat end drop of the THWTP including fluid structure interaction; (iii) verification of the analytical models by experiment

  20. Minimum joint space width (mJSW) of patellofemoral joint on standing ''skyline'' radiographs: test-retest reproducibility and comparison with quantitative magnetic resonance imaging (qMRI)

    International Nuclear Information System (INIS)

    Simoni, Paolo; Jamali, Sanaa; Alvarez Miezentseva, Victoria; Albert, Adelin; Totterman, Saara; Schreyer, Edward; Tamez-Pena, Jose G.; Zobel, Bruno Beomonte; Gillet, Philippe

    2013-01-01

    To assess the intraobserver, interobserver, and test-retest reproducibility of minimum joint space width (mJSW) measurement of medial and lateral patellofemoral joints on standing ''skyline'' radiographs and to compare the mJSW of the patellofemoral joint to the mean cartilage thickness calculated by quantitative magnetic resonance imaging (qMRI). A couple of standing ''skyline'' radiographs of the patellofemoral joints and MRI of 55 knees of 28 volunteers (18 females, ten males, mean age, 48.5 ± 16.2 years) were obtained on the same day. The mJSW of the patellofemoral joint was manually measured and Kellgren and Lawrence grade (KLG) was independently assessed by two observers. The mJSW was compared to the mean cartilage thickness of patellofemoral joint calculated by qMRI. mJSW of the medial and lateral patellofemoral joint showed an excellent intraobserver agreement (interclass correlation (ICC) = 0.94 and 0.96), interobserver agreement (ICC = 0.90 and 0.95) and test-retest agreement (ICC = 0.92 and 0.96). The mJSW measured on radiographs was correlated to mean cartilage thickness calculated by qMRI (r = 0.71, p < 0.0001 for the medial PFJ and r = 0.81, p < 0.0001 for the lateral PFJ). However, there was a lack of concordance between radiographs and qMRI for extreme values of joint width and KLG. Radiographs yielded higher joint space measures than qMRI in knees with a normal joint space, while qMRI yielded higher joint space measures than radiographs in knees with joint space narrowing and higher KLG. Standing ''skyline'' radiographs are a reproducible tool for measuring the mJSW of the patellofemoral joint. The mJSW of the patellofemoral joint on radiographs are correlated with, but not concordant with, qMRI measurements. (orig.)

  1. A Special Pre-Service-Inspection Using Radiographic Testing(RT) for Brazing Fitting used in Aircraft Hydraulic System

    International Nuclear Information System (INIS)

    Kim, Gyu Ho

    2010-01-01

    Brazing fitting which is one of the aircraft hydraulic power system components is widely used for saving weight and achieving higher reliability. Any inherent defects or damage of fitting can cause system failure and/or physical damage of human body due to highly pressurized fluid. Radiographic testing(RT) technique and additional micro-structure investigation on cut-away surfaces have been accomplished to find out some defect-like-inhomogeneity in the fittings. The radiography results showed that some defect-like-inhomogeneity existed inside body. Additional micro-structure investigation on cut-away surface reveals that the inhomogeneity is due to internal voids. In this study, it can be is said that RT technique can be a useful tool for field acceptance test of hydraulic brazing fitting in short time

  2. Testing a Novel 3D Printed Radiographic Imaging Device for Use in Forensic Odontology.

    Science.gov (United States)

    Newcomb, Tara L; Bruhn, Ann M; Giles, Bridget; Garcia, Hector M; Diawara, Norou

    2017-01-01

    There are specific challenges related to forensic dental radiology and difficulties in aligning X-ray equipment to teeth of interest. Researchers used 3D printing to create a new device, the combined holding and aiming device (CHAD), to address the positioning limitations of current dental X-ray devices. Participants (N = 24) used the CHAD, soft dental wax, and a modified external aiming device (MEAD) to determine device preference, radiographer's efficiency, and technique errors. Each participant exposed six X-rays per device for a total of 432 X-rays scored. A significant difference was found at the 0.05 level between the three devices (p = 0.0015), with the MEAD having the least amount of total errors and soft dental wax taking the least amount of time. Total errors were highest when participants used soft dental wax-both the MEAD and the CHAD performed best overall. Further research in forensic dental radiology and use of holding devices is needed. © 2016 American Academy of Forensic Sciences.

  3. A Large-Sample Test of a Semi-Automated Clavicle Search Engine to Assist Skeletal Identification by Radiograph Comparison.

    Science.gov (United States)

    D'Alonzo, Susan S; Guyomarc'h, Pierre; Byrd, John E; Stephan, Carl N

    2017-01-01

    In 2014, a morphometric capability to search chest radiograph databases by quantified clavicle shape was published to assist skeletal identification. Here, we extend the validation tests conducted by increasing the search universe 18-fold, from 409 to 7361 individuals to determine whether there is any associated decrease in performance under these more challenging circumstances. The number of trials and analysts were also increased, respectively, from 17 to 30 skeletons, and two to four examiners. Elliptical Fourier analysis was conducted on clavicles from each skeleton by each analyst (shadowgrams trimmed from scratch in every instance) and compared to the search universe. Correctly matching individuals were found in shortlists of 10% of the sample 70% of the time. This rate is similar to, although slightly lower than, rates previously found for much smaller samples (80%). Accuracy and reliability are thereby maintained, even when the comparison system is challenged by much larger search universes. © 2016 American Academy of Forensic Sciences.

  4. Radiographic positioning

    International Nuclear Information System (INIS)

    Eisenberg, R.L.; Dennis, C.A.; May, C.

    1989-01-01

    This book concentrates on the routine radiographic examinations commonly performed. It details the wide variety of examinations possible and their place in initial learning and in the radiology department as references for those occasions when an unusual examination is requested. This book provides information ranging from basic terminology to skeletal positioning to special procedures. Positions are discussed and supplemented with a picture of a patient, the resulting radiograph, and a labeled diagram. Immobilization and proper shielding of the patient are also shown

  5. Rapidly processable radiographic material

    International Nuclear Information System (INIS)

    Brabandere, L.A. de; Borginon, H.A.; Pattyn, H.A.; Pollet, R.J.

    1981-01-01

    A new rapidly processable radiographic silver halide material is described for use in mammography and non-destructive testing of industrial materials. The radiographic material is used for direct exposure to penetrating radiation without the use of fluorescent-intensifying screens. It consists of a transparent support with a layer of hydrophilic colloid silver halide emulsion on one or both sides. Examples of the preparation of three different silver halide emulsions are given including the use of different chemical sensitizers. These new radiographic materials have good resistance to the formation of pressure marks in rapid processing apparatus and they have improved sensitivity for direct exposure to penetrating radiation compared to conventional radiographic emulsions. (U.K.)

  6. How Informative are the Vertical Buoyancy and the Prone Gliding Tests to Assess Young Swimmers’ Hydrostatic and Hydrodynamic Profiles?

    Science.gov (United States)

    Barbosa, Tiago M.; Costa, Mário J.; Morais, Jorge E; Moreira, Marc; Silva, António J.; Marinho, Daniel A.

    2012-01-01

    The aim of this research was to develop a path-flow analysis model to highlight the relationships between buoyancy and prone gliding tests and some selected anthropometrical and biomechanical variables. Thirty-eight young male swimmers (12.97 ± 1.05 years old) with several competitive levels were evaluated. It were assessed the body mass, height, fat mass, body surface area, vertical buoyancy, prone gliding after wall push-off, stroke length, stroke frequency and velocity after a maximal 25 [m] swim. The confirmatory model included the body mass, height, fat mass, prone gliding test, stroke length, stroke frequency and velocity. All theoretical paths were verified except for the vertical buoyancy test that did not present any relationship with anthropometrical and biomechanical variables nor with the prone gliding test. The good-of-fit from the confirmatory path-flow model, assessed with the standardized root mean square residuals (SRMR), is considered as being close to the cut-off value, but even so not suitable of the theory (SRMR = 0.11). As a conclusion, vertical buoyancy and prone gliding tests are not the best techniques to assess the swimmer’s hydrostatic and hydrodynamic profile, respectively. PMID:23486528

  7. Radiographic and radioscopic testing of coatings with a high absorption coefficient

    International Nuclear Information System (INIS)

    Bourdarios, M.; Deleuze, M.; Lepoutre, M.

    1983-06-01

    Radiographies of a uranium disk obtained with an Ir192 source and a X-ray generator of 420kV are compared. Then a testing installation with a X-ray generator for high absorption material is studied. It comprises a mechanism to put the sample into position and a system for image processing to improve contrast and decrease background noise [fr

  8. Flaw acceptance criteria taking into consideration the NDT: radiographic and ultrasonic testing. Analysis through the fracture mechanics methods

    International Nuclear Information System (INIS)

    Capurro, E.; Alicino, F.; Corvi, A.

    1993-01-01

    The present study compares and evaluates the flaw acceptance criteria of the non-destructive inspections meeting European Community standards, through the application of the fracture mechanics methods that were determined and verified by the previous activity. Some choices were made; these, however, do not change the general validity of the conclusions. Shaved full-penetration butt welds of Class 1 components making up the primary circuit were considered and the following parameters varied: standards: French, German, Italian (ASME III) and UK; material: AISI 316 and low alloy steel A 533; base material and weld metal; temperature: RT, 370 deg C for the austenitic and 260 deg C for the ferritic steel; ultrasonic and radiographic methods; defect position: surface and internal; stress condition: situations with different primary and secondary stresses. From a preliminary examination of this study it is evident that the large quantity of results available and the abundance of information contained therein make a simple and exhaustive synthesis difficult. In fact, different analyses are possible and we have, therefore, limited the research to activities to perform a comparison and a general evaluation of the acceptance criteria of the non-destructive testing. (authors). 57 refs., 25 figs., 11 tabs

  9. Relativistic hydrodynamics

    CERN Document Server

    Luciano, Rezzolla

    2013-01-01

    Relativistic hydrodynamics is a very successful theoretical framework to describe the dynamics of matter from scales as small as those of colliding elementary particles, up to the largest scales in the universe. This book provides an up-to-date, lively, and approachable introduction to the mathematical formalism, numerical techniques, and applications of relativistic hydrodynamics. The topic is typically covered either by very formal or by very phenomenological books, but is instead presented here in a form that will be appreciated both by students and researchers in the field. The topics covered in the book are the results of work carried out over the last 40 years, which can be found in rather technical research articles with dissimilar notations and styles. The book is not just a collection of scattered information, but a well-organized description of relativistic hydrodynamics, from the basic principles of statistical kinetic theory, down to the technical aspects of numerical methods devised for the solut...

  10. Effectiveness of emergency nurses' use of the Ottawa Ankle Rules to initiate radiographic tests on improving healthcare outcomes for patients with ankle injuries: A systematic review.

    Science.gov (United States)

    Ho, Jonathan Ka-Ming; Chau, Janita Pak-Chun; Cheung, Nancy Man-Ching

    2016-11-01

    The Ottawa Ankle Rules provide guidelines for clinicians on the recommendation of radiographic tests to verify fractures in patients with ankle injuries. The use of the Ottawa Ankle Rules by emergency nurses has been suggested to minimise unnecessary radiographic-test requests and reduce patients' length of stay in emergency departments. However, the findings of studies in this area are inconsistent. A systematic review was conducted to synthesise the most accurate evidence available on the extent to which emergency nurses' use of the Ottawa Ankle Rules to initiate radiographic tests improves healthcare outcomes for patients with ankle injuries. The systematic review attempted to identify all relevant published and unpublished studies in English and Chinese from databases such as Ovid MEDLINE, EMBASE, ProQuest Health and Medical Complete, EBM Reviews, SPORTDiscus, CINAHL Plus, the British Nursing Index, Scopus, the Chinese Biomedical Literature Database, China Journal Net, WanFang Data, the National Central Library Periodical Literature System, HyRead, the Digital Dissertation Consortium, MedNar and Google Scholar. Two reviewers independently assessed the eligibility of all of the studies identified during the search, based on their titles and abstracts. If a study met the criteria for inclusion, or inconclusive information was available in its title and abstract, the full text was retrieved for further analysis. The methodological quality of all of the eligible studies was assessed independently by the two reviewers. The search of databases and other sources yielded 1603 records. The eligibility of 17 full-text articles was assessed, and nine studies met the inclusion criteria. All nine studies were subjected to narrative analysis, and five were meta-analysed. All of the studies investigated the use of the refined Ottawa Ankle Rules. The results indicated that emergency nurses' use of the refined Ottawa Ankle Rules minimised unnecessary radiographic-test requests

  11. Report on the behalf of the Foreign Affairs, Defence and Armed Forces Commission on the bill project authorizing the ratification of the treaty between the French Republic, the United-Kingdom of Great-Britain and Northern Ireland related to common hydrodynamic and radiographic installations

    International Nuclear Information System (INIS)

    Pintat, X.

    2011-01-01

    After a presentation of the main directions defined during the London summit for the French-British defence cooperation (convergence of interests and ambitions, cooperation in the operational, capacity, technological and industrial areas), this report more precisely presents and discusses the cooperation perspectives in the military nuclear field (deterrence by the French and British nuclear weapons, the experimentation as a field of cooperation, cooperation modalities with a common installation and a common technological development centre). These perspectives encompass experimentation installations aimed at the simulation of nuclear weapons. Then, it details the content of the treaty related to common hydrodynamic and radiographic installations: characteristics of the EPURE and TDC installations, financing conditions, and some other issues

  12. H1N1 influenza in an Irish population: patterns of chest radiograph abnormality in patients testing positive.

    LENUS (Irish Health Repository)

    O'Sullivan, K

    2012-02-29

    The winter of 2010\\/2011 saw a second peak in the number of H1N1 cases detected in Ireland. The purpose of this study was to investigate the radiological characteristics of patients diagnosed during this period. A retrospective analysis of these cases was performed. Chest radiographs were classified as normal or abnormal. A total of 37 patients were included. Of these, 22 (59%) of chest radiographs were abnormal and 15 (41%) were normal. In the 7 paediatric patients, 4 (57%) had a perihilar distribution of disease, 2 (28%) had peripherally based disease with 1 (14%) having a mixed distribution. A series of radiographs was available for 9 patients, 6 of these showed a radiographic deterioration from the initial study. The majority of chest radiographs of patients with confirmed H1N1 infection will be abnormal. In children, disease is more likely to be perihilar in distribution. Chest radiography is an important initial investigation in patients with H1N1 infection and is useful to track progression of disease in the subset of patients requiring hospitalization for severe disease.

  13. Assessing and Testing Hydrokinetic Turbine Performance and Effects on Open Channel Hydrodynamics: An Irrigation Canal Case Study.

    Energy Technology Data Exchange (ETDEWEB)

    Gunawan, Budi [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Neary, Vincent Sinclair [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Mortensen, Josh [United States Bureau of Reclamation, Denver, CO (United States); Roberts, Jesse D. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-05-01

    Hydrokinetic energy from flowing water in open channels has the potential to support local electricity needs with lower regulatory or capital investment than impounding water with more conventional means. MOU agencies involved in federal hydropower development have identified the need to better understand the opportunities for hydrokinetic (HK) energy development within existing canal systems that may already have integrated hydropower plants. This document provides an overview of the main considerations, tools, and assessment methods, for implementing field tests in an open-channel water system to characterize current energy converter (CEC) device performance and hydrodynamic effects. It describes open channel processes relevant to their HK site and perform pertinent analyses to guide siting and CEC layout design, with the goal of streamlining the evaluation process and reducing the risk of interfering with existing uses of the site. This document outlines key site parameters of interest and effective tools and methods for measurement and analysis with examples drawn from the Roza Main Canal, in Yakima, WA to illustrate a site application.

  14. Hydrodynamic bearings

    CERN Document Server

    Bonneau, Dominique; Souchet, Dominique

    2014-01-01

    This Series provides the necessary elements to the development and validation of numerical prediction models for hydrodynamic bearings. This book describes the rheological models and the equations of lubrication. It also presents the numerical approaches used to solve the above equations by finite differences, finite volumes and finite elements methods.

  15. Hydrodynamic Lubrication

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 1; Issue 9. Hydrodynamic Lubrication Experiment with 'Floating' Drops. Jaywant H Arakeri K R Sreenivas. General Article Volume 1 Issue 9 September 1996 pp 51-58. Fulltext. Click here to view fulltext PDF. Permanent link:

  16. Theoretical hydrodynamics

    CERN Document Server

    Milne-Thomson, L M

    2011-01-01

    This classic exposition of the mathematical theory of fluid motion is applicable to both hydrodynamics and aerodynamics. Based on vector methods and notation with their natural consequence in two dimensions - the complex variable - it offers more than 600 exercises and nearly 400 diagrams. Prerequisites include a knowledge of elementary calculus. 1968 edition.

  17. Hydrodynamic disperser

    Energy Technology Data Exchange (ETDEWEB)

    Bulatov, A.I.; Chernov, V.S.; Prokopov, L.I.; Proselkov, Yu.M.; Tikhonov, Yu.P.

    1980-01-15

    A hydrodynamic disperser is suggested which contains a housing, slit nozzles installed on a circular base arranged opposite from each other, resonators secured opposite the nozzle and outlet sleeve. In order to improve the effectiveness of dispersion by throttling the flow, each resonator is made in the form of a crimped plate with crimpings that decrease in height in a direction towards the nozzle.

  18. Test Specifications and the Design of the Wire Wrapped 37-Pin Fuel Assembly for Hydrodynamic Experiments

    International Nuclear Information System (INIS)

    Chang, S. K.; Euh, D. J.; Bae, H.; Lee, H. Y.; Choi, S. R.

    2013-01-01

    Most influencing parameters on uncertainties and sensitivities of the CFD analyses are the friction coefficient and the mixing coefficient. The friction coefficient is related to the flow distribution in reactor sub-channels. The mixing coefficient is defined with the cross flow between neighboring sub-channels. The eventual purpose of the thermal hydraulic design considering these parameters is to guarantee the fuel cladding integrity as the design limit parameter. At the moment, the experimental program is being undertaken to quantify these friction and mixing parameters which characterize the flow distribution in sub-channels, and the wire wrapped 37-pin rod assembly and its hexagonal test rig have been designed and fabricated. The quantified thermal hydraulic experimental data from this program are utilized primarily to estimate the accuracy of the safety analysis codes and their thermal hydraulic model. A wire wrapped 37 pin fuel assembly has been designed for the measurements of the flow distribution, where the measurements are utilized to quantify the friction coefficient and the mixing coefficient. The test rig of the wire wrapped 37 pin fuel assembly has been fabricated considering the geometric and flow dynamic similarities. It comprises four components i. e., the upper plenum, the fuel housing, the lower plenum, and the wire wrapped 37 pin fuel assembly. At further works, the quantified friction and mixing coefficients through the experiments are going to be utilized for insuring the reliability of the CFD analysis results

  19. GI Radiographic Tests

    Science.gov (United States)

    ... film as varying degrees of black, white, or gray. Barium Esophagram (Barium Swallow) Barium studies, also called ... ray films are then made and the colon anatomy is visualized. Abnormal findings may include colon cancer, ...

  20. A CAREM fuel assembly prototype construction in order to verify its mechanical design using hydrodynamic testing

    International Nuclear Information System (INIS)

    Aparicio, Gaspar; Di Marco, Agustin; Falcone, Jose M.; Giorgis, Miguel A.; Mathot, Sergio R.; Migliori, Julio; Orlando, Oscar S.; Restelli, Miguel A.; Ruggirello, Gabriel; Sapia, Gustavo C.; Zinzallari, Fausto; Bianchi, Daniel R.; Volpi, Ricardo M.

    2000-01-01

    The scope of this paper is to describe the activities of several Groups from three Atomic Centers (C. A. Bariloche, C. A. Ezeiza and C. A. Constituyentes), involved in the manufacturing of a CAREM fuel assembly prototype. The Design Group (UAIN-CAB) carried out the fuel assembly engineering. Cladding components were constructed by the Special Alloys Pilot Factory (UAMCN-CAE). Engineering Group (UACN-CAC) manufactured the parts to be processed, resorting to qualified suppliers. Elastic spacers were completely designed and constructed by this Group, and fuel rods, control rods, guide tubes and spacers were also welded here. Research Reactors Fuels Group (UACN-CAC) carried out the dimensional control of the elaborated parts, while Postirradiation Testing Group (UACN-CAC) performed the assembling of the fuel element. This paper also refers to the design and development of special equipment and devices, all of them required for the prototype construction. (author)

  1. Building Of Training Program Of Non-Destructive Testing For Concrete Structures (Part 1: Radiographic testing; Ultrasonic pulse velocity measurement; Nuclear moisture-density gauge)

    International Nuclear Information System (INIS)

    Nguyen Le Son; Phan Chanh Vu; Pham The Hung; Vu Huy Thuc

    2007-01-01

    Non-destructive testing methods (NDT) have been identified as a strong candidate for remote sensing of concrete structures over recent years. This has accelerated the powerful development of the NDT techniques in Vietnam. Hence, there is an urgent need to promote the awareness of NDT methods which could give an improved estimate of the condition concrete. Building of training program of non-destructive testing for concrete structures is a necessary duty, in aiming to build a unified training program, possibly satisfying the requirements on training as well as researching. Under the framework of the basic VAEC project (CS/07/02-03), a training program for the first 03 NDT methods: 1. Radiographic testing; 2. Ultrasonic pulse velocity measurement; 3. Nuclear moisture- density gauge was prepared. The main products of this project include: 1. Set out 03 training notes for 03 methods; 2. Set out the practical exercises to train for 03 methods; 3. Editing a set of examination questions in aiming to familiarize with various questions in 03 trained methods; 4. Fabricating practical test specimens to demonstrate for 03 techniques. (author)

  2. Hydrodynamic dispersion characteristics of lateral inflow into a river tested by a laboratory model

    Directory of Open Access Journals (Sweden)

    P. Y. Chou

    2009-02-01

    Full Text Available Groundwater and river-water have a different composition and interact in and below the riverbed. The riverbed-aquifer flux interactions have received growing interest because of their role in the exchange and transformation of nutrients and pollutants between rivers and the aquifer. In this research our main purpose is to identify the physical processes and characteristics needed for a numerical transport model, which includes the unsaturated recharge zone, the aquifer and the riverbed. In order to investigate such lateral groundwater inflow process, a laboratory J-shaped column experiment was designed. This study determined the transport parameters of the J-shaped column by fitting an analytical solution of the convective-dispersion equation for every flux on individual segments to the observed breakthrough curves of the resident concentration, and by inverse modelling for every flux simultaneously over the entire flow domain. The obtained transport-parameter relation was tested by numerical simulation using HYDRUS 2-D/3-D.

    Four steady-state flux conditions (i.e. 0.5 cm hr−1, 1 cm hr−1, 1.5 cm hr−1 and 2 cm hr−1 were applied, transport parameters including pore water velocity and dispersivity were determined for both unsaturated and saturated sections along the column. Results showed that under saturated conditions the dispersivity was fairly constant and independent of the flux. In contrast, dispersivity under unsaturated conditions was flux dependent and increased at lower flux. For our porous medium the dispersion coefficient related best to the quotient of the pore water velocity divided by the water content. A simulation model of riverbed-aquifer flux interaction should take this into account.

  3. Radiographic element

    International Nuclear Information System (INIS)

    Abbott, T.I.; Jones, C.G.

    1984-01-01

    Radiographic elements are disclosed comprised of first and second silver halide emulsion layers separated by an interposed support capable of transmitting radiation to which the second image portion is responsive. At least the first imaging portion contains a silver halide emulsion in which thin tubular silver halide grains of intermediate aspect ratios (from 5:1 to 8:1) are present. Spectral sensitizing dye is adsorbed to the surface of the tubular grains. Increased photographic speeds can be realized at comparable levels of crossover. (author)

  4. Interpretation and digestion of radiograph

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    Radiography digestion is final test for the radiography to make sure that radiograph produced will inspect their quality of the image before its interpreted. This level is critical level where if there is a mistake, all of the radiography work done before will be unaccepted. So as mention earlier, it can waste time, cost and more worst it can make the production must shut down. So, this step, level two radiographers or interpreter must evaluate the radiograph carefully. For this purpose, digestion room and densitometer must used. Of course all the procedure must follow the specification that mentioned in document. There are several needs must fill before we can say the radiograph is corrected or not like the location of penetrameter, number of penetrameter that showed, the degree of density of film, and usually there is no problem in this step and the radiograph can go to interpretation and evaluation step as will mentioned in next chapter.

  5. Radiographic apparatus

    International Nuclear Information System (INIS)

    Lapidus, S.N.

    1979-01-01

    Raytheon Company, U.S.A. have patented an on-line electronic system of normalising the responses from the photomultiplier tubes used in conjunction with a scintillator in an X-ray radiographic camera. A problem with present cameras is that the individual photomultipliers have different intensity responses which also change in time with respect to each other. The individual responses of each photomultiplier tube are measured with a uniform sheet of radioactive material in front of the camera. The associated electronic equipment then calculates scaling factors which give all photomultiplier tubes an identical response and then places these factors in an addressable store. The store is then addressed in an on-line mode to produce a visual display of the transmitted X-rays. (U.K.)

  6. Radiographic apparatus

    International Nuclear Information System (INIS)

    Dalton, B.L.

    1984-01-01

    This patent application describes a radiographic apparatus including an array of radiation sensors, a source of radiation for projecting a beam through a body and means for moving one of said source and array relative to the body and for producing an electrical signal representative of the movement of the other of said source and array needed to bring the array into register with the beam. Drive means are arranged to move the other of said source and array in response to the electrical signal. In one embodiment, the source is rotated by an amount measured by a grating and associated electronics. The required movement of the array to maintain registration is calculated and transmitted to a driver. Alternatively, a laser may be mounted with the same and the array driven so that the laser beam continuously impinges on a photocell mounted with the array. (author)

  7. Conditional non-independence of radiographic image features and the derivation of post-test probabilities – A mammography BI-RADS example

    International Nuclear Information System (INIS)

    Benndorf, Matthias

    2012-01-01

    Bayes' theorem has proven to be one of the cornerstones in medical decision making. It allows for the derivation of post-test probabilities, which in case of a positive test result become positive predictive values. If several test results are observed successively Bayes' theorem may be used with assumed conditional independence of test results or with incorporated conditional dependencies. Herein it is examined whether radiographic image features should be considered conditionally independent diagnostic tests when post-test probabilities are to be derived. For this purpose the mammographic mass dataset from the UCI (University of California, Irvine) machine learning repository is analysed. It comprises the description of 961 (516 benign, 445 malignant) mammographic mass lesions according to the BI-RADS (Breast Imaging: Reporting and Data System) lexicon. Firstly, an exhaustive correlation matrix is presented for mammography BI-RADS features among benign and malignant lesions separately; correlation can be regarded as measure for conditional dependence. Secondly, it is shown that the derived positive predictive values for the conjunction of the two features “irregular shape” and “spiculated margin” differ significantly depending on whether conditional dependencies are incorporated into the decision process or not. It is concluded that radiographic image features should not generally be regarded as conditionally independent diagnostic tests.

  8. Radiographers and trainee radiologists reporting accident radiographs

    DEFF Research Database (Denmark)

    Buskov, L; Abild, A; Christensen, A

    2013-01-01

    To compare the diagnostic accuracy and clinical validity of reporting radiographers with that of trainee radiologists whom they have recently joined in reporting emergency room radiographs at Bispebjerg University Hospital....

  9. Assessment of Radiographic Image Quality by Visual Examination of Neutron Radiographs of the Calibration Fuel Pin

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    Up till now no reliable radiographic image quality standards exist for neutron radiography of nuclear reactor fuel. Under the Euratoro Neutron Radiography Working Group (NRWG) Test Program neutron radiographs were produced at different neutron radiography facilities within the European Community...... of a calibration fuel pin. The radiographs were made by the direct, transfer and tracketch methods using different film recording materials. These neutron radiographs of the calibration fuel pin were used for the assessement of radiographic image quality. This was done by visual examination of the radiographs...

  10. Radiographic tales

    DEFF Research Database (Denmark)

    Mussmann, Bo Redder

    Purpose Until now a large number of scientific studies have focused on technological aspects of radiography. This study is a step in another direction which examines the relationship between man and technology within radiography instead of considering man and technology as separate entities. Meth...... of their narrative alertness. Errors and failure to keep the time schedule can, however, lead the radiographers to a change of perspective that makes them displace man from the scene of radiography by playing on the premises of technology.......Purpose Until now a large number of scientific studies have focused on technological aspects of radiography. This study is a step in another direction which examines the relationship between man and technology within radiography instead of considering man and technology as separate entities...... a practice in which the relationship between man and technology is marked by a struggle of domination of one over the other. The struggle expresses itself through two competing plots: A diagnostic plot with a prevailing, but not merely chronological structure mostly composed of events tied to pathology...

  11. Global SWOT Data Assimilation of River Hydrodynamic Model; the Twin Simulation Test of CaMa-Flood

    Science.gov (United States)

    Ikeshima, D.; Yamazaki, D.; Kanae, S.

    2016-12-01

    CaMa-Flood is a global scale model for simulating hydrodynamics in large scale rivers. It can simulate river hydrodynamics such as river discharge, flooded area, water depth and so on by inputting water runoff derived from land surface model. Recently many improvements at parameters or terrestrial data are under process to enhance the reproducibility of true natural phenomena. However, there are still some errors between nature and simulated result due to uncertainties in each model. SWOT (Surface water and Ocean Topography) is a satellite, which is going to be launched in 2021, can measure open water surface elevation. SWOT observed data can be used to calibrate hydrodynamics model at river flow forecasting and is expected to improve model's accuracy. Combining observation data into model to calibrate is called data assimilation. In this research, we developed data-assimilated river flow simulation system in global scale, using CaMa-Flood as river hydrodynamics model and simulated SWOT as observation data. Generally at data assimilation, calibrating "model value" with "observation value" makes "assimilated value". However, the observed data of SWOT satellite will not be available until its launch in 2021. Instead, we simulated the SWOT observed data using CaMa-Flood. Putting "pure input" into CaMa-Flood produce "true water storage". Extracting actual daily swath of SWOT from "true water storage" made simulated observation. For "model value", we made "disturbed water storage" by putting "noise disturbed input" to CaMa-Flood. Since both "model value" and "observation value" are made by same model, we named this twin simulation. At twin simulation, simulated observation of "true water storage" is combined with "disturbed water storage" to make "assimilated value". As the data assimilation method, we used ensemble Kalman filter. If "assimilated value" is closer to "true water storage" than "disturbed water storage", the data assimilation can be marked effective. Also

  12. Supernova hydrodynamics

    International Nuclear Information System (INIS)

    Colgate, S.A.

    1981-01-01

    The explosion of a star supernova occurs at the end of its evolution when the nuclear fuel in its core is almost, or completely, consumed. The star may explode due to a small residual thermonuclear detonation, type I SN or it may collapse, type I and type II SN leaving a neutron star remnant. The type I progenitor should be thought to be an old accreting white dwarf, 1.4 M/sub theta/, with a close companion star. A type II SN is thought to be a massive young star 6 to 10 M/sub theta/. The mechanism of explosion is still a challenge to our ability to model the most extreme conditions of matter and hydrodynamics that occur presently and excessively in the universe. 39 references

  13. Submarine hydrodynamics

    CERN Document Server

    Renilson, Martin

    2015-01-01

    This book adopts a practical approach and presents recent research together with applications in real submarine design and operation. Topics covered include hydrostatics, manoeuvring, resistance and propulsion of submarines. The author briefly reviews basic concepts in ship hydrodynamics and goes on to show how they are applied to submarines, including a look at the use of physical model experiments. The issues associated with manoeuvring in both the horizontal and vertical planes are explained, and readers will discover suggested criteria for stability, along with rudder and hydroplane effectiveness. The book includes a section on appendage design which includes information on sail design, different arrangements of bow planes and alternative stern configurations. Other themes explored in this book include hydro-acoustic performance, the components of resistance and the effect of hull shape. Readers will value the author’s applied experience as well as the empirical expressions that are presented for use a...

  14. Physical hydrodynamics

    CERN Document Server

    Guyon, Etienne; Petit, Luc; Mitescu, Catalin D

    2015-01-01

    This new edition is an enriched version of the textbook of fluid dynamics published more than 10 years ago. It retains the same physically oriented pedagogical perspective. This book emphasizes, as in the first edition, experimental inductive approaches and relies on the study of the mechanisms at play and on dimensional analysis rather than more formal approaches found in many classical textbooks in the field. The need for a completely new version also originated from the increase, over the last few decades, of the cross-overs between the mechanical and physical approaches, as is visible in international meetings and joint projects. Hydrodynamics is more widely linked today to other fields of experimental sciences: materials, environment, life sciences and earth sciences, as well as engineering sciences.

  15. Introduction to hydrodynamics

    International Nuclear Information System (INIS)

    Wilkins, M.L.

    1979-01-01

    Various aspects of hydrodynamics and elastic--plastic flow are introduced for the purpose of defining hydrodynamic terms and explaining what some of the important hydrodynamic concepts are. The first part covers hydrodynamic theory; and discussed fundamental hydrodynamic equations, discontinuities, and shock, detonation, and elastic--plastic waves. The second part deals with applications of hydrodynamic theory to material equations of state, spall, Taylor instabilities, and detonation pressure measurements

  16. Thermo-hydrodynamic lubrication in hydrodynamic bearings

    CERN Document Server

    Bonneau, Dominique; Souchet, Dominique

    2014-01-01

    This Series provides the necessary elements to the development and validation of numerical prediction models for hydrodynamic bearings. This book describes the thermo-hydrodynamic and the thermo-elasto-hydrodynamic lubrication. The algorithms are methodically detailed and each section is thoroughly illustrated.

  17. Annual Report: Hydrodynamics and Radiative Hydrodynamics with Astrophysical Applications

    Energy Technology Data Exchange (ETDEWEB)

    R. Paul Drake

    2005-12-01

    We report the ongoing work of our group in hydrodynamics and radiative hydrodynamics with astrophysical applications. During the period of the existing grant, we have carried out two types of experiments at the Omega laser. One set of experiments has studied radiatively collapsing shocks, obtaining high-quality scaling data using a backlit pinhole and obtaining the first (ever, anywhere) Thomson-scattering data from a radiative shock. Other experiments have studied the deeply nonlinear development of the Rayleigh-Taylor (RT) instability from complex initial conditions, obtaining the first (ever, anywhere) dual-axis radiographic data using backlit pinholes and ungated detectors. All these experiments have applications to astrophysics, discussed in the corresponding papers either in print or in preparation. We also have obtained preliminary radiographs of experimental targets using our x-ray source. The targets for the experiments have been assembled at Michigan, where we also prepare many of the simple components. The above activities, in addition to a variety of data analysis and design projects, provide good experience for graduate and undergraduates students. In the process of doing this research we have built a research group that uses such work to train junior scientists.

  18. Equipment for fully automatic radiographic pipe inspection

    International Nuclear Information System (INIS)

    Basler, G.; Sperl, H.; Weinschenk, K.

    1977-01-01

    The patent describes a device for fully automatic radiographic testing of large pipes with longitudinal welds. Furthermore the invention enables automatic marking of films in radiographic inspection with regard to a ticketing of the test piece and of that part of it where testing took place. (RW) [de

  19. Hydrodynamic dispersion

    International Nuclear Information System (INIS)

    Pryce, M.H.L.

    1985-01-01

    A dominant mechanism contributing to hydrodynamic dispersion in fluid flow through rocks is variation of travel speeds within the channels carrying the fluid, whether these be interstices between grains, in granular rocks, or cracks in fractured crystalline rocks. The complex interconnections of the channels ensure a mixing of those parts of the fluid which travel more slowly and those which travel faster. On a macroscopic scale this can be treated statistically in terms of the distribution of times taken by a particle of fluid to move from one surface of constant hydraulic potential to another, lower, potential. The distributions in the individual channels are such that very long travel times make a very important contribution. Indeed, while the mean travel time is related to distance by a well-defined transport speed, the mean square is effectively infinite. This results in an asymmetrical plume which differs markedly from a gaussian shape. The distribution of microscopic travel times is related to the distribution of apertures in the interstices, or in the microcracks, which in turn are affected in a complex way by the stresses acting on the rock matrix

  20. Chromatin Hydrodynamics

    Science.gov (United States)

    Bruinsma, Robijn; Grosberg, Alexander Y.; Rabin, Yitzhak; Zidovska, Alexandra

    2014-01-01

    Following recent observations of large scale correlated motion of chromatin inside the nuclei of live differentiated cells, we present a hydrodynamic theory—the two-fluid model—in which the content of a nucleus is described as a chromatin solution with the nucleoplasm playing the role of the solvent and the chromatin fiber that of a solute. This system is subject to both passive thermal fluctuations and active scalar and vector events that are associated with free energy consumption, such as ATP hydrolysis. Scalar events drive the longitudinal viscoelastic modes (where the chromatin fiber moves relative to the solvent) while vector events generate the transverse modes (where the chromatin fiber moves together with the solvent). Using linear response methods, we derive explicit expressions for the response functions that connect the chromatin density and velocity correlation functions to the corresponding correlation functions of the active sources and the complex viscoelastic moduli of the chromatin solution. We then derive general expressions for the flow spectral density of the chromatin velocity field. We use the theory to analyze experimental results recently obtained by one of the present authors and her co-workers. We find that the time dependence of the experimental data for both native and ATP-depleted chromatin can be well-fitted using a simple model—the Maxwell fluid—for the complex modulus, although there is some discrepancy in terms of the wavevector dependence. Thermal fluctuations of ATP-depleted cells are predominantly longitudinal. ATP-active cells exhibit intense transverse long wavelength velocity fluctuations driven by force dipoles. Fluctuations with wavenumbers larger than a few inverse microns are dominated by concentration fluctuations with the same spectrum as thermal fluctuations but with increased intensity. PMID:24806919

  1. Measure by image analysis of industrial radiographs

    International Nuclear Information System (INIS)

    Brillault, B.

    1988-01-01

    A digital radiographic picture processing system for non destructive testing intends to provide the expert with computer tool, to precisely quantify radiographic images. The author describes the main problems, from the image formation to its characterization. She also insists on the necessity to define a precise process in order to automatize the system. Some examples illustrate the efficiency of digital processing for radiographic images [fr

  2. A contribution to quality control in veterinary radiology. Development and calibration of a test-phantom for the control of the picture quality of radiographs of the abdomen of the cat

    International Nuclear Information System (INIS)

    Mueller-Wabro, A.

    1996-10-01

    The theme of this thesis was the extension of the application of a test phantom developed at the institute of medical physics (University of Veterinary Medicine/Vienna) and the calibration for the abdomen of the cat. The test phantom is a stepped test body consisting of a material, which absorbs and scatters X-rays similar to bony tissue. On the baseplate of the staircase there are holes 0.5 and 0.7 mm in diameter. Objective parameters of a radiograph - radiographic density latitude, contrast and detail visibility - can be examined with the phantom. By using subjective 'good' rated radiographs it was possible to establish an indirect relation between the soft tissue of the abdomen and the phantom by comparing the optical density. Thus the practicability of the application for abdominal radiographs could be demonstrated. The recognizability of the holes means a measure of detail visibility. For the represented parameters of an X-ray picture are connected, one can conclude radiograph quality from detail visibility. On the basis of the results of a judgement by test-persons a nomogram was designed, which is of use in quick classifying and controlling X-ray pictures. (author)

  3. Radiographic imaging. 4 ed.

    International Nuclear Information System (INIS)

    Chesney, D.N.; Chesney, M.O.

    1981-01-01

    This is a revised edition of the textbook previously entitled 'Radiographic Photography' and accords with the current syllabus of training for the Diploma of the Royal College of Radiographers. The aim is a non-mathematical approach to provide a guide for the student to the knowledge and understanding of the theoretical concepts which affect the quality of radiographic image; materials and practices are also reviewed, particularly in relation to the characteristics of the radiographic image, and to processing equipment and processing areas. The subject is dealt with under the following headings: the photographic process, film materials in x-ray departments, sensitometry, storage of film materials and radiographs, intensifying screens and cassettes, film processing, developing, fixing, rinsing, washing, drying, the processing area and equipment, systems for daylight film handling, the radiographic image, management of the quality, presentation of the radiograph, light images and their recording, fluorography, some special imaging processes, e.g. xerography, copying radiographs. (U.K.)

  4. Actual questions of radiographic testing and radiation protection. Contributions; Aktuelle Fragen der Durchstrahlungspruefung und des Strahlenschutzes. Beitraege

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2017-08-01

    The proceedings of the 17th DGZfP seminar include nine contributions on the use of radiography for periodic non destructive testing purposes and issues of radiation protection for the testing personnel and the security of radioactive materials.

  5. Conversion into numerical form of radiographic images

    International Nuclear Information System (INIS)

    Cappabianca, C.; Della Rocca, A.B.; Ferriani, S.

    1986-01-01

    Radiographic means are widely used for non destructive testing. However, human and technological factors strongly influence reliability of the results and further use of these technique. Image Processing can help to overtake those difficulties if radiographic films are previously digitized. This paper shows methods and equipments used in this field. The system EDI (Enea Digital. Imagery) operating in Casaccia Energy Research Centre is described

  6. Automatic Cobb Angle Determination From Radiographic Images

    NARCIS (Netherlands)

    Sardjono, Tri Arief; Wilkinson, Michael H. F.; Veldhuizen, Albert G.; van Ooijen, Peter M. A.; Purnama, Ketut E.; Verkerke, Gijsbertus J.

    2013-01-01

    Study Design. Automatic measurement of Cobb angle in patients with scoliosis. Objective. To test the accuracy of an automatic Cobb angle determination method from frontal radiographical images. Summary of Background Data. Thirty-six frontal radiographical images of patients with scoliosis. Methods.

  7. Quality of radiograph

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    This chapter discussed on how to get a good radiograph. There are several factors that can make good radiograph such as density of radiograph, the contrast of radiograph, definition of radiograph, the present of artifact and backscattering. All of this factor will discuss detailed on each unit of chapter with some figure, picture to make the reader understand more when read this book. And at the end, the reader will introduce with penetrameter, one of device to determine the level of quality of the radiograph. There are two type of penetrameter like wire type or holes type. This standard must be followed by all the radiographer around the world to produce the good result that is standard and more reliable.

  8. Beryllium abundances along the evolutionary sequence of the open cluster IC 4651 - A new test for hydrodynamical stellar models

    Science.gov (United States)

    Smiljanic, R.; Pasquini, L.; Charbonnel, C.; Lagarde, N.

    2010-02-01

    Context. Previous analyses of lithium abundances in main sequence and red giant stars have revealed the action of mixing mechanisms other than convection in stellar interiors. Beryllium abundances in stars with Li abundance determinations can offer valuable complementary information on the nature of these mechanisms. Aims: Our aim is to derive Be abundances along the whole evolutionary sequence of an open cluster. We focus on the well-studied open cluster IC 4651. These Be abundances are used with previously determined Li abundances, in the same sample stars, to investigate the mixing mechanisms in a range of stellar masses and evolutionary stages. Methods: Atmospheric parameters were adopted from a previous abundance analysis by the same authors. New Be abundances have been determined from high-resolution, high signal-to-noise UVES spectra using spectrum synthesis and model atmospheres. The careful synthetic modeling of the Be lines region is used to calculate reliable abundances in rapidly rotating stars. The observed behavior of Be and Li is compared to theoretical predictions from stellar models including rotation-induced mixing, internal gravity waves, atomic diffusion, and thermohaline mixing. Results: Beryllium is detected in all the main sequence and turn-off sample stars, both slow- and fast-rotating stars, including the Li-dip stars, but is not detected in the red giants. Confirming previous results, we find that the Li dip is also a Be dip, although the depletion of Be is more modest than for Li in the corresponding effective temperature range. For post-main-sequence stars, the Be dilution starts earlier within the Hertzsprung gap than expected from classical predictions, as does the Li dilution. A clear dispersion in the Be abundances is also observed. Theoretical stellar models including the hydrodynamical transport processes mentioned above are able to reproduce all the observed features well. These results show a good theoretical understanding of the

  9. Thermal hydro-dynamic behavior of the nuclear-powered ship Mutsu in the power-up test

    International Nuclear Information System (INIS)

    Ishida, Toshihisa; Kusunoki, Tsuyoshi; Tanaka, Yoshimi; Yao, Toshiaki; Inoue, Kimio; Ochiai, Masa-aki

    1991-01-01

    The first Japanese nuclear ship N.S. Mutsu was tested with heavy load changes as ones of the full scale start-up tests. This paper describes the results of power increasing test, test of crash astern propulsion from ahead cruising, and turbine trip test; In the power increasing test, the main steam flow rate increased from 20 % flow to 70 % flow in 13 seconds; In the test of crash astern propulsion from ahead cruising, an astern turbine maneuvering handle was drawn to the position equivalent to about 60 % reactor power in 30 seconds after an ahead turbine stopping; In the turbine trip test, the ahead turbine was tripped manually at about 100 % power operation. From these tests it was verified that the Mutsu reactor is capable to respond smoothly and safely to the heavy load change without reactor scram, without workings of the pressurizer relief valve and main steam dump valve, and without need of any manual adjustment of the reactor control system. (author)

  10. Radiographers and trainee radiologists reporting accident radiographs: A comparative plain film-reading performance study

    International Nuclear Information System (INIS)

    Buskov, L.; Abild, A.; Christensen, A.; Holm, O.; Hansen, C.; Christensen, H.

    2013-01-01

    Aim: To compare the diagnostic accuracy and clinical validity of reporting radiographers with that of trainee radiologists whom they have recently joined in reporting emergency room radiographs at Bispebjerg University Hospital. Materials and methods: Plain radiographs of the appendicular skeleton from 1000 consecutive emergency room patients were included in the study: 500 primarily reported by radiographers and 500 by trainee radiologists. The final reporting was subsequently undertaken by a consultant radiologist in consensus with an orthopaedic surgeon. Two observers classified reports as either true positive/negative or false positive/negative based on the final report, which was considered the reference standard. To evaluate the severity of incorrect primary reports, errors were graded into three categories concerning clinical impact and erroneous reports graded as the most severe category were subsequently analysed. Mann–Whitney and Chi-squared tests were used to compare differences and associations between radiographers versus trainee radiologists regarding film reporting. Results: The sensitivity for correct diagnosis was 99% for reporting radiographers and 94% for trainee radiologists. The specificity was found to be 97% for reporting radiographers and 99% for trainee radiologists. Radiographers missed significantly fewer fractures (n = 2) than trainee radiologists (n = 14; p = 0.006) but had a higher, but not significant, degree of overcalling. No significant difference was found between groups regarding clinical impact of incorrect reporting. Conclusion: Trained radiographers report accident radiographs of the extremities with high accuracy and constitute a qualified resource to help meet increasing workload and demands in quality standards.

  11. Visual simulation of radiographs

    International Nuclear Information System (INIS)

    Laguna, G.

    1985-01-01

    A method for computer simulation of radiographs has been added to the LLNL version of the solid modeler TIPS-1 (Technical Information Processing System-1). This new tool will enable an engineer to compare an actual radiograph of a solid to its computer-generated counterpart. The appearance of discrepancies between the two can be an indication of flaws in the solid object. Simulated radiographs can also be used to preview the placement of x-ray sources to focus on areas of concern before actual radiographs are made

  12. Minimum joint space width (mJSW) of patellofemoral joint on standing ''skyline'' radiographs: test-retest reproducibility and comparison with quantitative magnetic resonance imaging (qMRI)

    Energy Technology Data Exchange (ETDEWEB)

    Simoni, Paolo; Jamali, Sanaa; Alvarez Miezentseva, Victoria [CHU de Liege, Diagnostic Imaging Departement, Domanine du Sart Tilman, Liege (Belgium); Albert, Adelin [CHU de Liege, Biostatistics Departement, Domanine du Sart Tilman, Liege (Belgium); Totterman, Saara; Schreyer, Edward; Tamez-Pena, Jose G. [Qmetrics Technologies, Rochester, NY (United States); Zobel, Bruno Beomonte [Campus Bio-Medico University, Diagnostic Imaging Departement, Rome (Italy); Gillet, Philippe [CHU de Liege, Orthopaedic surgery Department, Domanine du Sart Tilman, Liege (Belgium)

    2013-11-15

    To assess the intraobserver, interobserver, and test-retest reproducibility of minimum joint space width (mJSW) measurement of medial and lateral patellofemoral joints on standing ''skyline'' radiographs and to compare the mJSW of the patellofemoral joint to the mean cartilage thickness calculated by quantitative magnetic resonance imaging (qMRI). A couple of standing ''skyline'' radiographs of the patellofemoral joints and MRI of 55 knees of 28 volunteers (18 females, ten males, mean age, 48.5 {+-} 16.2 years) were obtained on the same day. The mJSW of the patellofemoral joint was manually measured and Kellgren and Lawrence grade (KLG) was independently assessed by two observers. The mJSW was compared to the mean cartilage thickness of patellofemoral joint calculated by qMRI. mJSW of the medial and lateral patellofemoral joint showed an excellent intraobserver agreement (interclass correlation (ICC) = 0.94 and 0.96), interobserver agreement (ICC = 0.90 and 0.95) and test-retest agreement (ICC = 0.92 and 0.96). The mJSW measured on radiographs was correlated to mean cartilage thickness calculated by qMRI (r = 0.71, p < 0.0001 for the medial PFJ and r = 0.81, p < 0.0001 for the lateral PFJ). However, there was a lack of concordance between radiographs and qMRI for extreme values of joint width and KLG. Radiographs yielded higher joint space measures than qMRI in knees with a normal joint space, while qMRI yielded higher joint space measures than radiographs in knees with joint space narrowing and higher KLG. Standing ''skyline'' radiographs are a reproducible tool for measuring the mJSW of the patellofemoral joint. The mJSW of the patellofemoral joint on radiographs are correlated with, but not concordant with, qMRI measurements. (orig.)

  13. Characterisation of the hydrodynamic properties within THE EDZ around drifts at level - 490 m of the Bure URL: a methodology for consistent interpretation of hydraulic tests

    International Nuclear Information System (INIS)

    Baechler, S.; Lavanchy, J.M.; Armand, G.; Cruchaudet, M.

    2010-01-01

    Document available in extended abstract form only. Since 2004 the characterisation of the excavated damaged zone (EDZ) around drifts, has been performed at several sites in the underground research laboratory (URL) at Bure. The experiments were conducted around drifts at depths of 445 and 490 meters below ground surface. The EDZ is a highly complex and heterogeneous system of fractures/fissures, with variable pore pressure gradients (including suction conditions), sharp changes in permeability/transmissivity properties, unsaturated conditions, etc. In addition, the hydrodynamic properties within the EDZ may change with time in association with effects such as stress redistribution, variable conditions in the drifts (temperature, humidity), and self-sealing/self-healing processes. In order to investigate potential changes of the hydrodynamic properties of the EDZ over time, several tests campaigns have been carried out between 2005 and 2008 in dedicated boreholes filled with either synthetic water or gas. Each test series was analyzed independently to previous results, in an attempt to optimise the fit of the new test measurements. The flow model was chosen according to diagnostic techniques. The analysis considered constraining (bounding) criteria for properties such as storage coefficient and formation pressure. After several test series, inconsistencies were noticed between the estimated conductivities, indicating sometimes erratic, non-explainable property changes over time and space. It was therefore difficult to determine reliable trends of the EDZ hydrodynamic properties. It appeared necessary to re-evaluate both the representation concepts and assumptions applied to the numerical analyses of test data on the EDZ, trying to better constrain the flow model and the parameter variables in order to generate a more realistic approximation of the geometrical, geomechanical and hydrodynamic properties of the EDZ. One particular issue was to conceptualize (in a

  14. Digital interactive learning of oral radiographic anatomy.

    Science.gov (United States)

    Vuchkova, J; Maybury, T; Farah, C S

    2012-02-01

    Studies reporting high number of diagnostic errors made from radiographs suggest the need to improve the learning of radiographic interpretation in the dental curriculum. Given studies that show student preference for computer-assisted or digital technologies, the purpose of this study was to develop an interactive digital tool and to determine whether it was more successful than a conventional radiology textbook in assisting dental students with the learning of radiographic anatomy. Eighty-eight dental students underwent a learning phase of radiographic anatomy using an interactive digital tool alongside a conventional radiology textbook. The success of the digital tool, when compared to the textbook, was assessed by quantitative means using a radiographic interpretation test and by qualitative means using a structured Likert scale survey, asking students to evaluate their own learning outcomes from the digital tool. Student evaluations of the digital tool showed that almost all participants (95%) indicated that the tool positively enhanced their learning of radiographic anatomy and interpretation. The success of the digital tool in assisting the learning of radiographic interpretation is discussed in the broader context of learning and teaching curricula, and preference (by students) for the use of this digital form when compared to the conventional literate form of the textbook. Whilst traditional textbooks are still valued in the dental curriculum, it is evident that the preference for computer-assisted learning of oral radiographic anatomy enhances the learning experience by enabling students to interact and better engage with the course material. © 2011 John Wiley & Sons A/S.

  15. Legalities of the radiograph

    International Nuclear Information System (INIS)

    Bundy, A.L.

    1988-01-01

    The radiograph itself plays a major role in medical malpractice cases. Also, many questions arise concerning the rights to and storage of x-ray films. These issues are addressed in this chapter. To keep the terminology simple, the word radiograph represents all imaging documentation on hard copy film (x-rays, nuclear medicine, computer-assisted studies, ultrasound, and magnetic resonance imaging)

  16. Data bank on hydrodynamics, thermal tests and tube temperature regimes of PGV-4 and PVG-1000 natural steam generators

    Energy Technology Data Exchange (ETDEWEB)

    Ageev, A.G.; Vasileva, R.V.; Nigmatulin, B.I.; Titov, V.F.; Tarankov, G.N. [EREC Electrogorsk Research and Engineering Centre of Nuclear Plants Safety, Moscow (Russian Federation)

    1995-12-31

    The data bank was prepared by EREC, OKB `Hydropress` using results of static and dynamic tests of PGV-4 and PGV- 1000 natural steam generators cared out at Kolskaya, Novo-Voronezhskaya, Ugno-Ukrainskaya, Balakov-skaya and Hmelnitskaya NPP within period of 1974-1993. It is destined for making calculation codes verification. (authors).

  17. Data bank on hydrodynamics, thermal tests and tube temperature regimes of PGV-4 and PVG-1000 natural steam generators

    Energy Technology Data Exchange (ETDEWEB)

    Ageev, A G; Vasileva, R V; Nigmatulin, B I; Titov, V F; Tarankov, G N [EREC Electrogorsk Research and Engineering Centre of Nuclear Plants Safety, Moscow (Russian Federation)

    1996-12-31

    The data bank was prepared by EREC, OKB `Hydropress` using results of static and dynamic tests of PGV-4 and PGV- 1000 natural steam generators cared out at Kolskaya, Novo-Voronezhskaya, Ugno-Ukrainskaya, Balakov-skaya and Hmelnitskaya NPP within period of 1974-1993. It is destined for making calculation codes verification. (authors).

  18. Hydrodynamic effects on coalescence.

    Energy Technology Data Exchange (ETDEWEB)

    Dimiduk, Thomas G.; Bourdon, Christopher Jay; Grillet, Anne Mary; Baer, Thomas A.; de Boer, Maarten Pieter; Loewenberg, Michael (Yale University, New Haven, CT); Gorby, Allen D.; Brooks, Carlton, F.

    2006-10-01

    The goal of this project was to design, build and test novel diagnostics to probe the effect of hydrodynamic forces on coalescence dynamics. Our investigation focused on how a drop coalesces onto a flat surface which is analogous to two drops coalescing, but more amenable to precise experimental measurements. We designed and built a flow cell to create an axisymmetric compression flow which brings a drop onto a flat surface. A computer-controlled system manipulates the flow to steer the drop and maintain a symmetric flow. Particle image velocimetry was performed to confirm that the control system was delivering a well conditioned flow. To examine the dynamics of the coalescence, we implemented an interferometry capability to measure the drainage of the thin film between the drop and the surface during the coalescence process. A semi-automated analysis routine was developed which converts the dynamic interferogram series into drop shape evolution data.

  19. Elasto-hydrodynamic lubrication

    CERN Document Server

    Dowson, D; Hopkins, D W

    1977-01-01

    Elasto-Hydrodynamic Lubrication deals with the mechanism of elasto-hydrodynamic lubrication, that is, the lubrication regime in operation over the small areas where machine components are in nominal point or line contact. The lubrication of rigid contacts is discussed, along with the effects of high pressure on the lubricant and bounding solids. The governing equations for the solution of elasto-hydrodynamic problems are presented.Comprised of 13 chapters, this volume begins with an overview of elasto-hydrodynamic lubrication and representation of contacts by cylinders, followed by a discussio

  20. Elementary classical hydrodynamics

    CERN Document Server

    Chirgwin, B H; Langford, W J; Maxwell, E A; Plumpton, C

    1967-01-01

    Elementary Classical Hydrodynamics deals with the fundamental principles of elementary classical hydrodynamics, with emphasis on the mechanics of inviscid fluids. Topics covered by this book include direct use of the equations of hydrodynamics, potential flows, two-dimensional fluid motion, waves in liquids, and compressible flows. Some general theorems such as Bernoulli's equation are also considered. This book is comprised of six chapters and begins by introducing the reader to the fundamental principles of fluid hydrodynamics, with emphasis on ways of studying the motion of a fluid. Basic c

  1. Hydrodynamic Data for Manoeuvring and Control of an AUV Determined by Tank Tests and Free-Sailing Trials

    DEFF Research Database (Denmark)

    Aage, Christian

    1998-01-01

    Autonomous Underwater Vehicles (AUV's) can be used for a large number of subsea acitivities in different modes of operation varying from the ROV-mode with on-line control and power supply from the surface, to the true AUV-mode where the vehicle performs its pre-programmed tasks with full autonomy...... manoeuvres, such as turning circles and zigzag tests. Similar free-sailing manoeuvrability trials are described and compared to the simulations. The free-sailing manoeuvres were monitored by the Differential Global Positioning System (DGPS)....

  2. Computational hydrodynamic comparison of a mini vessel and a USP 2 dissolution testing system to predict the dynamic operating conditions for similarity of dissolution performance.

    Science.gov (United States)

    Wang, Bing; Bredael, Gerard; Armenante, Piero M

    2018-03-25

    The hydrodynamic characteristics of a mini vessel and a USP 2 dissolution testing system were obtained and compared to predict the tablet-liquid mass transfer coefficient from velocity distributions near the tablet and establish the dynamic operating conditions under which dissolution in mini vessels could be conducted to generate concentration profiles similar to those in the USP 2. Velocity profiles were obtained experimentally using Particle Image Velocimetry (PIV). Computational Fluid Dynamics (CFD) was used to predict the velocity distribution and strain rate around a model tablet. A CFD-based mass transfer model was also developed. When plotted against strain rate, the predicted tablet-liquid mass transfer coefficient was found to be independent of the system where it was obtained, implying that a tablet would dissolve at the same rate in both systems provided that the concentration gradient between the tablet surface and the bulk is the same, the tablet surface area per unit liquid volume is identical, and the two systems are operated at the appropriate agitation speeds specified in this work. The results of this work will help dissolution scientists operate mini vessels so as to predict the dissolution profiles in the USP 2, especially during the early stages of drug development. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Research reactor fuel bundle design review by means of hydrodynamic testing; Ensayos hidrodinamicos para verificacion de diseno de un elemento combustible para reactores de investigacion

    Energy Technology Data Exchange (ETDEWEB)

    Pastorini, A; Belinco, C [Comision Nacional de Energia Atomica, San Martin (Argentina). Centro Atomico Constituyentes

    1998-12-31

    During the design steps of a fuel bundle for a nuclear reactor, some vibration tests are usually necessary to verify the prototype dynamical response characteristics and the structural integrity. To perform these tests, the known hydrodynamic loop facilities are used to evaluate the vibrational response of the bundle under the different flow conditions that may appear in the reactor. This paper describes the tests performed on a 19 plate fuel bundle prototype designed for a low power research reactor. The tests were done in order to know the dynamical characteristics of the plates and also of the whole bundle under different flow rate conditions. The paper includes a description of the test facilities and the results obtained during the dynamical characterization tests and some preliminary comments about the tests under flowing water are also presented. (author) 4 refs., 12 figs., 4 tabs. [Espanol] Durante el diseno de un elemento combustible para un reactor nuclear se requiere de la realizacion de ensayos con el objeto de verificar el comportamiento de ese diseno y permitir, de ser necesario, la introduccion de modificaciones al mismo. Para verificar las caracteristicas de respuesta dinamica e integridad estructural, se realizan ensayos de vibraciones que incluyen someter al prototipo a condiciones de circulacion del fluido similares a las que soportara durante la operacion del reactor. Estos ensayos se realizan en facilidades de ensayos conocidas como circuitos hidrodinamicos, que permiten no solo someter el prototipo al flujo de fluido, sino tambien obtener una adecuada caracterizacion de la respuesta del mismo a traves del luso de sensores de distinto tipo. En este trabajo se describen los ensayos realizados sobre un prototipo de elemento combustible de 19 placas destinado a un reactor de investigacion multiproposito de baja potencia. Los ensayos tuvieron como objetivo conocer la respuesta dinamica de las placas individuales y del elemento combustible en su

  4. Field Tests on Hydrodynamic and Hybrid Operation of a Bidirectional Thrust Bearing of a Pump-Turbine

    Directory of Open Access Journals (Sweden)

    Michał Wasilczuk

    2017-12-01

    Full Text Available In vertical shaft pump turbines operating in pumped storage power plants an important role is played by a thrust bearing. Due to the bidirectional character of operation, thrust bearing tilting pads have to be supported symmetrically, which is known to be unfavourable from the point of view of their performance. Large thrust bearings have to be carefully designed so as to minimise excessive thermo-elastic pad deformations. The research into fluid film thrust bearings has been quite extensive over the years, comprising theoretical studies of bearing properties with the use of more and more sophisticated calculation codes. On the other hand, the availability of experimental field data on bearing operation is limited, for obvious reasons. In this paper the authors present part of the results of extensive field tests of a large bearing of a pump-turbine they have conducted in a pumped storage power plant. Hopefully this data will be of interest to other researchers to compare theoretical predictions to measurement data.

  5. Comparative testing of radiographic testing, ultrasonic testing and phased array advanced ultrasonic testing non destructive testing techniques in accordance with the AWS D1.5 bridge welding code.

    Science.gov (United States)

    2014-02-01

    A comprehensive body of non-destructive testing data was collected from steel bridge welds under real-world conditions in a fabricators shop. Three different non-destructive testing (NDT) techniques were used on each weld inspection, these being R...

  6. Producing quality radiographic images

    International Nuclear Information System (INIS)

    Cullinan, A.M.

    1987-01-01

    This book gives an overview of physics, equipment, imaging, and quality assurance in the radiology department. The chapters are laid out with generous use of subheads to allow for quick reference, Points are illustrated with clear, uncluttered line diagrams and well-produced images. The accompanying explanations are miniature lessons by themselves. Inserted at various points throughout the text are important notes that highlight key concepts. The chapter ''Image Evaluation and Application of Radiographic Principles'' present a systematic approach to evaluating radiographs and contains several sample radiographs to illustrate the points made

  7. Engineering Hydrodynamic AUV Hulls

    Science.gov (United States)

    Allen, J.

    2016-12-01

    AUV stands for autonomous underwater vehicle. AUVs are used in oceanography and are similar to gliders. MBARIs AUVs as well as other AUVs map the ocean floor which is very important. They also measure physical characteristics of the water, such as temperature and salinity. My science fair project for 4th grade was a STEM activity in which I built and tested 3 different AUV bodies. I wanted to find out which design was the most hydrodynamic. I tested three different lengths of AUV hulls to see which AUV would glide the farthest. The first was 6 inches. The second was 12 inches and the third was 18 inches. I used clay for the nosecone and cut a ruler into two and made it the fin. Each AUV used the same nosecone and fin. I tested all three designs in a pool. I used biomimicry to create my hypothesis. When I was researching I found that long slim animals swim fastest. So, my hypothesis is the longer AUV will glide farthest. In the end I was right. The longer AUV did glide the farthest.

  8. Radiographic manifestations of hypochondroplasia

    Energy Technology Data Exchange (ETDEWEB)

    Heselson, N G; Cremin, B J [Groote Schuur Hospital, Cape Town (South Africa); Beighton, P

    1979-01-01

    Hypochrondroplasia is an inherited skeletal dysplasia that resembles achondroplasia in mild degree. Radiographic manifestations encountered in 12 affected individuals in South Africa include slight shortening of all segments of the tubular bones, moderate caudal diminution of the lumbar interpedicular distances, increased lumbar lordosis with cacral tilt and distal prolongation of the fibular. Hypochondroplasia can be distinguished from other osteochondrodystrophies such as achondroplasia, pseudo-achondroplasia and metaphyseal chondroplasia by the recognition of it clinical and radiographic manifestations.

  9. Radiographic examination of the equine foot

    International Nuclear Information System (INIS)

    Park, R.D.

    1989-01-01

    A complete radiographic examination of the equine foot consists of properly exposed, processed, and positioned radiographs. For radiographic interpretation, in addition to knowing radiographic signs of disease, a knowledge of normal radiographic anatomy and possible insignificant anatomic variations is necessary

  10. Radiographic interpretation of the appendicular skeleton: A comparison between casualty officers, nurse practitioners and radiographers

    International Nuclear Information System (INIS)

    Coleman, Liz; Piper, Keith

    2009-01-01

    Aim: To assess how accurately and confidently casualty officers, nurse practitioners and radiographers, practicing within the emergency department (ED), recognize and describe radiographic trauma within an image test bank of 20 appendicular radiographs. Method: The participants consisted of 7 casualty officers, 13 nurse practitioners and 18 radiographers. All 20 radiographic examinations selected for the image test bank had been acquired following trauma and included some subtle, yet clinically significant abnormalities. The test bank score (maximum 40 marks), sensitivity and specificity percentages were calculated against an agreed radiological diagnosis (reference standard). Alternative Free-response Receiver Operating Characteristic (AFROC) analysis was used to assess the overall performance of the diagnostic accuracy of these professional groups. The variation in performance between each group was measured using the analysis of variance (ANOVA) test, to identify any statistical significant differences in the performance in interpretation between these groups. The relationship between the participants' perceived image interpretation accuracy during clinical practice and the actual accuracy of their image test bank score was examined using Pearson's Correlation Coefficient (r). Results: The results revealed that the radiographers gained the highest mean test bank score (28.5/40; 71%). This score was statistically higher than the mean test bank scores attained by the participating nurse practitioners (21/40; 53%) and casualty officers (21.5/40; 54%), with p < 0.01 and p = 0.02, respectively. When compared with each other, the scores from these latter groups showed no significant difference (p = 0.91). The mean 'area under the curve' (AUC) value achieved by the radiographers was also significantly higher (p < 0.01) in comparison to the AUC values demonstrated by the nurse practitioners and casualty officers, whose results, when compared, showed no significant

  11. Evaluation of underexposed conventional radiographs after digitization

    International Nuclear Information System (INIS)

    Wenz, W.

    1993-01-01

    Inadequate exposure of analogue radiographs is reported in the literature to occur in 5-25% of cases. Therefore, the present study was performed to test whether selective image processing after digitization could reveal diagnostic details on underexposed radiographs. In addition, the minimal exposure values required for diagnostic purposes after adequate image processing were studied. Phantom studies, organ preparations and measurements of physical parameters with decreasing exposure values were performed. The detection of anatomic and pathologic (nondisplaced fracture lines, microcalcification and renal stones) structures were evaluated by 12 readers. Radiographs with exposure values 20-40% lower than 'ideal' values can provide adequate diagnostic images after digital processing. The diagnostic information is significantly impaired with values under 50% of the correct exposure values. In conclusion, this method is adequate to save underexposed radiographs for diagnostic purposes and to avoid repeated examinations. (orig.) [de

  12. Development of low-silver radiographic detectors

    International Nuclear Information System (INIS)

    Troitskij, V.A.; Novikov, I.A.; Nikitin, V.F.; Krasnyj-Admoni, L.V.; Valevich, M.I.; Belyj, N.G.; Grom, V.S.

    1988-01-01

    The results of investigations on radiographic testing of welded joints of St20, 08Kh18N10T steels, the AMG-6 alloy, copper, titanium using radiographic detectors with the low silver content are presented. The roentgenographic and photographic paper, as well as the samples of experimental films with heavy elements in the photolayer are tested using intensifying screens of different types. Experimental films containing silver 2 times as less as standard X-ray films are shown to provide the similar sensitivity of testing under equal conditions, but the exposure time is two times higher. Prints on the radiophotographic paper in quality and exposure time approach to prints obtained on the RT-1 film containing silver 10 times less than that in the roentgenographic film. The exposure time of the radiographic paper is several times less than that of the ''unibrom'' contrast paper. The testing sensitivity decreases to some extent in this case

  13. Radiation protection education and training of radiographers

    International Nuclear Information System (INIS)

    Elsakkers, P.

    1995-01-01

    The International Society of Radiographers and Radiological Technicians (ISRRT) is an international non-governmental organisation in official relationship with the World Health Organization. Over 50 countries are members of the ISRRT. The ISRRT encourages and facilitates communication between radiographers throughout the world. The ISRRT has produced several documents, e.g. ''The Role of the Radiographer in Europe''. The ISRRT has also done research and developed initiatives to analyse the quality of training of radiographers in the different member states of the EC. Research was done in the member states to analyse the efforts in the field of quality control. An extended study was performed on the current level of education in radiation protection in the European member states. The ICRP recommends in its publications the need of good training and continuing education for all radiographers. An important part of the basic training of radiographers should focus on the performance of radiation protection and quality control tests. Good daily practice can decrease patient dose in many ways. (Author)

  14. A radiographic study of pediatric ulnar anatomy.

    Science.gov (United States)

    Cravino, Mattia; Oni, Julius K; Sala, Debra A; Chu, Alice

    2014-01-01

    The adult ulna has a unique bony architecture that has been described in the literature, but, to the best of our knowledge, the ulnar anatomy in children has not been described. We examined 75 anteroposterior (AP) and 64 lateral radiographs (29 were bilateral) of 50, 0.5- to 11-year-old, healthy children's forearms. On AP radiographs, the total ulnar length, the ulnar proximal angle, the ulnar distal angle, and the distance between each angle from the tip of the triceps insertion; and, on lateral radiographs, the ulnar length and bow deviation were measured. The correlation between age and radiographic measurements, differences based on sex, differences compared with adults' measurements, and interobserver/intraobserver reliability were assessed. Age had a very strong/strong positive correlation with length/distance measurements on both AP and lateral radiographs. Only AP ulnar distal angle was significantly different between sexes (females > males). Compared with the adult ulnar studies, the AP proximal angle in children is significantly smaller and the location of this angle is significantly more distal. Interobserver and intraobserver reliability were very good for length/distance measurements on AP and lateral radiographs. The knowledge of pediatric ulnar anatomy could be helpful in the treatment of forearm deformities due to multiple hereditary exostosis and osteogenesis imperfecta, and in the treatment of ulnar fractures, particularly in Monteggia variants, where restoration of the correct forearm anatomy is essential to obtain good clinical and functional results. Study of diagnostic test, Level II.

  15. A contribution of quality assurance in veterinary radiography: further development and calibration of a test phantom to control the radiographic quality of X-rays of the equine hock joint

    International Nuclear Information System (INIS)

    Grohmann, D.

    1996-10-01

    The test phantom, which was elaborated by PARISOT (1988), was further developed and calibrated for the equine hock joint. As bigger bone layers had to be radiated, in comparison with the already existing calibration, a new material with higher radiographic density was used for the construction of a new test phantom. A copper test phantom, constructed like a staircase, containing drill-holes in the bottom plate, was used. This practical test phantom, on the highest step only 2.3 mm thick, should prove to be small enough to suit to the daily use in the equine practice. The photographs of each of the views were judged by a specialist in equine medicine and classified into three groups with the criteria 'too light', 'good' and 'too dark'. Then 15 test subjects determined the upper limit of the visibility of the two drillings. After statistical analysis of the data, standard ranges for the three photographing directions were fixed and nomograms were made. As a result of simultaneous photographing of the test phantom and the hock joint of interest, the observer is able to assess the quality of the radiograph. Determining the upper limit of visibility of the holes in the staircase, he can judge the photograph as suitable, too light or too dark for diagnostic use. (author)

  16. Radiographic aspects of xeroradiography

    International Nuclear Information System (INIS)

    Rao, G.U.V.; Fatouros, P.P.

    1980-01-01

    The quality of a conventional radiographic image can be characterized in terms of five basic parameters; density, contrast, latitude, resolution and noise. Since xeroradiographic images exhibit very limited broad area contrasts, and image formation is predominantly due to edge enhancement, a straightforward description of image quality using the same five parameters is not adequate. A detailed study was made of the radiographic aspects of xeroradiography with special reference to mammography, and a summary of major findings to date with appropriate references to published papers is presented

  17. Numerical Hydrodynamics in Special Relativity.

    Science.gov (United States)

    Martí, José Maria; Müller, Ewald

    2003-01-01

    This review is concerned with a discussion of numerical methods for the solution of the equations of special relativistic hydrodynamics (SRHD). Particular emphasis is put on a comprehensive review of the application of high-resolution shock-capturing methods in SRHD. Results of a set of demanding test bench simulations obtained with different numerical SRHD methods are compared. Three applications (astrophysical jets, gamma-ray bursts and heavy ion collisions) of relativistic flows are discussed. An evaluation of various SRHD methods is presented, and future developments in SRHD are analyzed involving extension to general relativistic hydrodynamics and relativistic magneto-hydrodynamics. The review further provides FORTRAN programs to compute the exact solution of a 1D relativistic Riemann problem with zero and nonzero tangential velocities, and to simulate 1D relativistic flows in Cartesian Eulerian coordinates using the exact SRHD Riemann solver and PPM reconstruction. Supplementary material is available for this article at 10.12942/lrr-2003-7 and is accessible for authorized users.

  18. Nondestructive examination - radiographic techniques

    International Nuclear Information System (INIS)

    Maier, H.J.

    1980-01-01

    First the basic principles of radiography are to be treated, especially the different radiation sources (X-ray, gamma-ray, neutrons, heat). In the second part those radiographic methods are shown, which are in common use for technical purposes, especially under the aspect of flaw recognition. (orig./RW)

  19. Matching hand radiographs

    NARCIS (Netherlands)

    Kauffman, J.A.; Slump, Cornelis H.; Bernelot Moens, H.J.

    2005-01-01

    Biometric verification and identification methods of medical images can be used to find possible inconsistencies in patient records. Such methods may also be useful for forensic research. In this work we present a method for identifying patients by their hand radiographs. We use active appearance

  20. Stabilized radiographic scanning agent

    International Nuclear Information System (INIS)

    Fawzi, M.B.

    1979-01-01

    A stable composition useful in preparation of technetium-99m-based radiographic scanning agents has been developed. The composition contains a stabilizing amount of gentisate stabilizer selected from gentisic acid and its soluble pharmaceutically-acceptable salts and esthers. (E.G.)

  1. Radiographic scanning agent

    International Nuclear Information System (INIS)

    Tofe, A.J.

    1976-01-01

    A stable radiographic scanning agent on a sup(99m)Tc basis has been developed. The substance contains a pertechnetate reduction agent, tin(II)-chloride, chromium(II)-chloride, or iron(II)-sulphate, as well as an organospecific carrier and ascorbic acid or a pharmacologically admissible salt or ester of ascorbic acid. (VJ) [de

  2. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.J.

    1986-01-01

    This book is directed towards giving radiographers an introduction to and basic knowledge of computerized tomography. The technical section discusses gantries and x-ray production, computer and disc drive image display, storage, artefacts quality assurance and design of departments. The clinical section includes patient preparation, radiotherapy planning, and interpretation of images from various areas of the anatomy. (U.K.)

  3. Hydrodynamic optical soliton tunneling

    Science.gov (United States)

    Sprenger, P.; Hoefer, M. A.; El, G. A.

    2018-03-01

    A notion of hydrodynamic optical soliton tunneling is introduced in which a dark soliton is incident upon an evolving, broad potential barrier that arises from an appropriate variation of the input signal. The barriers considered include smooth rarefaction waves and highly oscillatory dispersive shock waves. Both the soliton and the barrier satisfy the same one-dimensional defocusing nonlinear Schrödinger (NLS) equation, which admits a convenient dispersive hydrodynamic interpretation. Under the scale separation assumption of nonlinear wave (Whitham) modulation theory, the highly nontrivial nonlinear interaction between the soliton and the evolving hydrodynamic barrier is described in terms of self-similar, simple wave solutions to an asymptotic reduction of the Whitham-NLS partial differential equations. One of the Riemann invariants of the reduced modulation system determines the characteristics of a soliton interacting with a mean flow that results in soliton tunneling or trapping. Another Riemann invariant yields the tunneled soliton's phase shift due to hydrodynamic interaction. Soliton interaction with hydrodynamic barriers gives rise to effects that include reversal of the soliton propagation direction and spontaneous soliton cavitation, which further suggest possible methods of dark soliton control in optical fibers.

  4. Hydrodynamic Expansion of Pellicles Caused by e-Beam Heating

    CERN Document Server

    Ho, D

    2000-01-01

    Placing a pellicle in front of a x-ray converter target for radiographic applications can confine the backstreaming ions and target plasma to a shorter channel so that the cumulative effect on e-beam focusing is reduced. The pellicle is subject to heating by e-beam since the pellicle is placed upstream of the target. The calculation of the hydrodynamic expansion, caused by the heating, using the radiation hydrodynamics code LASNEX is presented in this report. Calculations show that mylar pellicles disintegrate at the end of a multi-pulse intense e-beam while beryllium and carbon pellicles remain intact. The expansions for the kapton-carbon multi-layered targets are also examined. Hydrodynamic expansions for pellicles with various e-beam spot radii are calculated for DARHT-II beam parameters. All the simulation results indicate that the backstreaming ions can be stopped.

  5. Radiographic progession of rheumatoid arthritis

    International Nuclear Information System (INIS)

    Siozos, C.D.

    1981-01-01

    The radiographic progression of rheumatoid arthritis can be graded on a 0-IV scala. For this purpose five objective criteria are used: a) destruction, b) osteoporosis, c) narrowing of joint space, d) luxation and e) ankylosis. The grading of the radiographic progression is defined by the extent and the number of the measured alterations. The radiographic progression can be registered yearly. (orig.) [de

  6. Small systems – hydrodynamics

    Energy Technology Data Exchange (ETDEWEB)

    Bożek, Piotr, E-mail: piotr.bozek@fis.agh.edu.pl

    2016-12-15

    The scenario assuming a collective expansion stage in collisions of small systems, p-A, d-Au, and {sup 3}He-Au is discussed. A review of the observables predicted in relativistic hydrodynamic models in comparison with experimental data is presented, with arguments indicating the presence of collective expansion. The limits of applicability of the hydrodynamic model are addressed. We briefly indicate possible applications of the collective flow in small systems to study the space-time dynamics at very small scales in relativistic collisions.

  7. Radiographic and tomographic study of the elbow joint in dogs

    International Nuclear Information System (INIS)

    Sendyk-Grunkraut, Alessandra; Martin, Claudia M.; Souza, Alexandre N.A.; Patricio, Geni Cristina F.; Lorigados, Carla A.B.; Matera, Julia M.; Fonseca-Pinto, Ana C.B.C.

    2017-01-01

    Elbow dysplasia disease includes an united anconeal process, fragmented medial coronoid process, osteochondrosis of humeral trochlea, articular incongruity and degenerative joint disease. The aim of this study was to present detailed morphologic and morphometric aspects of the elbow joint in dog in clinical and correlate with radiographic and tomographic (CT) exam. Inter-observer variation for articular incongruity measurements by CT, comparative analysis in the radiographic exam, angle in ulnar notch and its comparative analysis between radiographic and tomographic agreement examination in 44 elbow of dogs with different ages were evaluated. The statistics analyses included the kappa coefficient and interclass correlation and Fischer's test and McNemar's test. It was evidenced that individual performance of each radiographic incidence had poor agreement with the tomographic exam, suggesting that the accomplishment of more than two radiograph views are needed. There was no agreement between the three evaluators in the ulnar notch angle at radiographic and tomographic exams. However, there was good/moderate agreement for articular incongruity measurement in the sagittal plane between evaluators. It was possible to conclude that none of the five radiographic incidences was better than the others for radiographic analysis because each incidence had a better identification of a particular elbow compartment; measurements at the tomographic exam to evaluate radioulnar incongruity had no reproductiveness in the frontal plane, but in sagittal plan had a good/moderate agreement between observers and the angle in ulnar notch presented no repeatability at radiographic exam and no reproductiveness at tomographic exam. (author)

  8. Assessment for hydrodynamic masses of HANARO flow tubes

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Jeong Soo; Cho, Yeong Garp; Kim, Doo Kie; Woo, Jong Sug; Park, Jin Ho

    2000-06-01

    The effect of hydrodynamic masses is investigated in dynamic characteristics and seismic response analyses of the submerged HANARO hexagonal flow tubes. Consistent hydrodynamic masses of the surrounding water are evaluated by the prepared program using the finite element method, in which arbitrary cross-sections of submerged structures and boundary conditions of the surrounding fluid can be considered. Also lumped hydrodynamic masses are calculated using simple formula applied to hexagonal flow tubes in the infinite fluid. Modal analyses and seismic response spectrum analyses were performed using hydrodynamic masses obtained by the finite element method and the simple formula. The results of modal analysis were verified by comparing the results measured from modal tests. And the displacement results of the seismic response spectrum analysis were assessed by comparing the consistent and the lumped hydrodynamic masses obtained by various methods. Finally practical criteria based on parametric studies are proposed as the lumped hydrodynamic masses for HANARO flow tubes.

  9. Assessment for hydrodynamic masses of HANARO flow tubes

    International Nuclear Information System (INIS)

    Ryu, Jeong Soo; Cho, Yeong Garp; Kim, Doo Kie; Woo, Jong Sug; Park, Jin Ho

    2000-06-01

    The effect of hydrodynamic masses is investigated in dynamic characteristics and seismic response analyses of the submerged HANARO hexagonal flow tubes. Consistent hydrodynamic masses of the surrounding water are evaluated by the prepared program using the finite element method, in which arbitrary cross-sections of submerged structures and boundary conditions of the surrounding fluid can be considered. Also lumped hydrodynamic masses are calculated using simple formula applied to hexagonal flow tubes in the infinite fluid. Modal analyses and seismic response spectrum analyses were performed using hydrodynamic masses obtained by the finite element method and the simple formula. The results of modal analysis were verified by comparing the results measured from modal tests. And the displacement results of the seismic response spectrum analysis were assessed by comparing the consistent and the lumped hydrodynamic masses obtained by various methods. Finally practical criteria based on parametric studies are proposed as the lumped hydrodynamic masses for HANARO flow tubes

  10. Modeling dental radiographic systems

    International Nuclear Information System (INIS)

    Webber, R.L.

    1980-01-01

    The Bureau of Radiological Health has been actively collaborating with the Clinical Investigations Branch, NIDR, in applied research involving diagnostic use of ionizing radiation in dentistry. This work has centered on the search for alternatives to conventional radiographic systems in an attempt to improve diagnostic performance while reducing the required exposure. The basic approach involves analysis of factors limiting performance of properly defined diagnostic tasks and the modeling alternative systems with an eye toward increasing objective measures of performance. Previous collaborative work involved using a nonlinear model to compare various x-ray spectra. The data were expressed as brightness-contrast versus exposure for simulated tasks of clinical interest. This report supplements these findings by extending the number of parameters under investigation and modifying the mode of data display so that an actual radiographic image can be simulated on a television screen

  11. Pocket atlas of radiographic anatomy

    International Nuclear Information System (INIS)

    Moeller, T.B.; Reif, E.; Stark, P.

    1993-01-01

    The 'Pocket Atlas of Radiographic Anatomy' presents 170 radiographs of the various body regions of adults, showing only the normal radiographic anatomy. Each radiograph is supplemented on the opposite page by a drawing of the particular body region. There is no commenting text, but the drawings are provided with captions in English. The atlas is a useful guide for interpreting radiographs. The pictures are arranged in chapters entitled as follows: Skeletal Imaging (skull, spine, upper extremity), lower extremity; Miscellaneous Plain Films (chest, mammogram, trachea, lung tomograms); Contrast Examinations (gastrointestinal tract, intravenous contrast examinations, arthrography, angiography); Special Examinations (myelograms, lymphangiograms, bronchograms, sialograms). (UWA). 348 figs [de

  12. Hydrodynamical description of collective flow

    OpenAIRE

    Huovinen, Pasi

    2003-01-01

    I review how hydrodynamical flow is related to the observed flow in ultrarelativistic heavy ion collisions and how initial conditions, equation of state and freeze-out temperature affect flow in hydrodynamical models.

  13. Report on the behalf of the Foreign Affairs, Defence and Armed Forces Commission on the bill project authorizing the ratification of the treaty between the French Republic, the United-Kingdom of Great-Britain and Northern Ireland related to common hydrodynamic and radiographic installations; Rapport fait au nom de la commission des affaires etrangeres, de la defense et des forces armees (1) sur le projet de loi autorisant la ratification du traite entre la Republique francaise et le Royaume-Uni de Grande Bretagne et d'Irlande du nord relatif a des installations radiographiques et hydrodynamiques communes

    Energy Technology Data Exchange (ETDEWEB)

    Pintat, X.

    2011-07-01

    After a presentation of the main directions defined during the London summit for the French-British defence cooperation (convergence of interests and ambitions, cooperation in the operational, capacity, technological and industrial areas), this report more precisely presents and discusses the cooperation perspectives in the military nuclear field (deterrence by the French and British nuclear weapons, the experimentation as a field of cooperation, cooperation modalities with a common installation and a common technological development centre). These perspectives encompass experimentation installations aimed at the simulation of nuclear weapons. Then, it details the content of the treaty related to common hydrodynamic and radiographic installations: characteristics of the EPURE and TDC installations, financing conditions, and some other issues

  14. CT should replace three-view radiographs as the initial screening test in patients at high, moderate, and low risk for blunt cervical spine injury: a prospective comparison.

    Science.gov (United States)

    Bailitz, John; Starr, Frederic; Beecroft, Matthew; Bankoff, Jon; Roberts, Roxanne; Bokhari, Faran; Joseph, Kimberly; Wiley, Dorian; Dennis, Andrew; Gilkey, Susan; Erickson, Paul; Raksin, Patricia; Nagy, Kimberly

    2009-06-01

    An estimated 10,000 Americans suffer cervical spine injuries each year. More than 800,000 cervical spine radiographs (CSR) are ordered annually. The human and healthcare costs associated with these injuries are enormous especially when diagnosis is delayed. Controversy exists in the literature concerning the diagnostic accuracy of CSR, with reported sensitivity ranging from 32% to 89%. We sought to compare prospectively the sensitivity of cervical CT (CCT) to CSR in the initial diagnosis of blunt cervical spine injury for patients meeting one or more of the NEXUS criteria. The study prospectively compared the diagnostic accuracy of CSR to CCT in consecutive patients evaluated for blunt trauma during 23 months at an urban, public teaching hospital and Level I Trauma Center. Inclusion criteria were adult patient, evaluated for blunt cervical spine injury, meeting one or more of the NEXUS criteria. All patients received both three-view CSR and CCT as part of a standard diagnostic protocol. Each CSR and CCT study was interpreted independently by a different radiology attending who was blinded to the results of the other study. Clinically significant injuries were defined as those requiring one or more of the following interventions: operative procedure, halo application, and/or rigid cervical collar. Of 1,583 consecutive patients evaluated for blunt cervical spine trauma, 78 (4.9%) patients received only CCT or CSR and were excluded from the study. Of the remaining 1,505 patients, 78 (4.9%) had evidence of a radiographic injury by CSR or CCT. Of these 78 patients with radiographic injury, 50 (3.3%) patients had clinically significant injuries. CCT detected all patients with clinically significant injuries (100% sensitive), whereas CSR detected only 18 (36% sensitive). Of the 50 patients, 15 were at high risk, 19 at moderate risk, and 16 at low risk for cervical spine injury according to previously published risk stratification. CSR detected clinically significant

  15. Dissipative relativistic hydrodynamics

    International Nuclear Information System (INIS)

    Imshennik, V.S.; Morozov, Yu.I.

    1989-01-01

    Using the comoving reference frame in the general non-inertial case, the relativistic hydrodynamics equations are derived with an account for dissipative effects in the matter. From the entropy production equation, the exact from for the dissipative tensor components is obtained. As a result, the closed system of equations of dissipative relativistic hydrodynamics is obtained in the comoving reference frame as a relativistic generalization of the known Navier-Stokes equations for Lagrange coordinates. Equations of relativistic hydrodynamics with account for dissipative effects in the matter are derived using the assocoated reference system in general non-inertial case. True form of the dissipative tensor components is obtained from entropy production equation. Closed system of equations for dissipative relativistic hydrodynamics is obtained as a result in the assocoated reference system (ARS) - relativistic generalization of well-known Navier-Stokes equations for Lagrange coordinates. Equation system, obtained in this paper for ARS, may be effectively used in numerical models of explosive processes with 10 51 erg energy releases which are characteristic for flashes of supernovae, if white dwarf type compact target suggested as presupernova

  16. Radiographic findings in immunodeficiency

    International Nuclear Information System (INIS)

    Obregon, R.; Lynch, D.A.; Cink, T.M.; Newell, J.D.; Kirkpatrick, C.

    1991-01-01

    This paper reviews the chest radiographs and high-resolution CT (HRCT) scans in patients with immunodeficiency disorders and define the role of HRCT. Thirty-three cases were retrospectively graded according to the consensus of two radiologists. Patients with HIV seropositivity and asthma were excluded. HRCT was performed in 12 cases with standard techniques. Diagnoses included common variable hypogammaglobulinemia (n = 19), X-linked agammaglobulinemia (n = 4), chronic mucocutaneous candidiasis (n = 4), and selective immunoglobulin g deficiencies (n = 2). Chest radiographs showed bronchiectasis in 11 of 33 cases with a predominant lower lobe distribution (82%). Nodules were present in six cases and mucus plugs in four cases. HRCT showed bronchiectasis in nine of 12 cases; in five of these nine cases, bronchiectasis was not apparent on chest radiographs. Other HRCT findings included segmental air trapping (four of 12), mucus plugs (three of 12), hazy consolidation (four of 12), nodules (five of 12), and bronchiolectasis (two of 12). Therapy was altered in seven of 12 cases in which HRCT was performed. Most pertinent to clinical management were the presence of a thymoma (n = 1) and severe focal of diffuse bronchiectasis

  17. Large Format Radiographic Imaging

    International Nuclear Information System (INIS)

    Rohrer, J. S.; Stewart, Lacey; Wilke, M. D.; King, N. S.; Baker A, S.; Lewis, Wilfred

    1999-01-01

    Radiographic imaging continues to be a key diagnostic in many areas at Los Alamos National Laboratory (LANL). Radiographic recording systems have taken on many form, from high repetition-rate, gated systems to film recording and storage phosphors. Some systems are designed for synchronization to an accelerator while others may be single shot or may record a frame sequence in a dynamic radiography experiment. While film recording remains a reliable standby in the radiographic community, there is growing interest in investigating electronic recording for many applications. The advantages of real time access to remote data acquisition are highly attractive. Cooled CCD camera systems are capable of providing greater sensitivity with improved signal-to-noise ratio. This paper begins with a review of performance characteristics of the Bechtel Nevada large format imaging system, a gated system capable of viewing scintillators up to 300 mm in diameter. We then examine configuration alternatives in lens coupled and fiber optically coupled electro-optical recording systems. Areas of investigation include tradeoffs between fiber optic and lens coupling, methods of image magnification, and spectral matching from scintillator to CCD camera. Key performance features discussed include field of view, resolution, sensitivity, dynamic range, and system noise characteristics

  18. Radiograph identifying means

    International Nuclear Information System (INIS)

    Sheldon, A.D.

    1983-01-01

    A flexible character-indentable plastics embossing tape is backed by and bonded to a lead strip, not more than 0.025 inches thick, to form a tape suitable for identifying radiographs. The lead strip is itself backed by a relatively thin and flimsy plastics or fabric strip which, when removed, allows the lead plastic tape to be pressure-bonded to the surface to be radiographed. A conventional tape-embossing gun is used to indent the desired characters in succession into the lead-backed tape, without necessarily severing the lead; and then the backing strip is peeled away to expose the layer of adhesive which pressure-bonds the indented tape to the object to be radiographed. X-rays incident on the embossed tape will cause the raised characters to show up dark on the subsequently-developed film, whilst the raised side areas will show up white. Each character will thus stand out on the developed film. (author)

  19. Entropy-limited hydrodynamics: a novel approach to relativistic hydrodynamics

    Science.gov (United States)

    Guercilena, Federico; Radice, David; Rezzolla, Luciano

    2017-07-01

    We present entropy-limited hydrodynamics (ELH): a new approach for the computation of numerical fluxes arising in the discretization of hyperbolic equations in conservation form. ELH is based on the hybridisation of an unfiltered high-order scheme with the first-order Lax-Friedrichs method. The activation of the low-order part of the scheme is driven by a measure of the locally generated entropy inspired by the artificial-viscosity method proposed by Guermond et al. (J. Comput. Phys. 230(11):4248-4267, 2011, doi: 10.1016/j.jcp.2010.11.043). Here, we present ELH in the context of high-order finite-differencing methods and of the equations of general-relativistic hydrodynamics. We study the performance of ELH in a series of classical astrophysical tests in general relativity involving isolated, rotating and nonrotating neutron stars, and including a case of gravitational collapse to black hole. We present a detailed comparison of ELH with the fifth-order monotonicity preserving method MP5 (Suresh and Huynh in J. Comput. Phys. 136(1):83-99, 1997, doi: 10.1006/jcph.1997.5745), one of the most common high-order schemes currently employed in numerical-relativity simulations. We find that ELH achieves comparable and, in many of the cases studied here, better accuracy than more traditional methods at a fraction of the computational cost (up to {˜}50% speedup). Given its accuracy and its simplicity of implementation, ELH is a promising framework for the development of new special- and general-relativistic hydrodynamics codes well adapted for massively parallel supercomputers.

  20. Assessment of radiation protection practices among radiographers ...

    African Journals Online (AJOL)

    Application of shielding devices such as gonad shield for protection was neglected mostly in government hospitals. Most x-ray machines were quite old and evidence of quality assurance tests performed on such machines were lacking. Conclusion: Radiographers within Lagos metropolis showed an excellent knowledge of ...

  1. Digital processing of radiographic images

    Science.gov (United States)

    Bond, A. D.; Ramapriyan, H. K.

    1973-01-01

    Some techniques are presented and the software documentation for the digital enhancement of radiographs. Both image handling and image processing operations are considered. The image handling operations dealt with are: (1) conversion of format of data from packed to unpacked and vice versa; (2) automatic extraction of image data arrays; (3) transposition and 90 deg rotations of large data arrays; (4) translation of data arrays for registration; and (5) reduction of the dimensions of data arrays by integral factors. Both the frequency and the spatial domain approaches are presented for the design and implementation of the image processing operation. It is shown that spatial domain recursive implementation of filters is much faster than nonrecursive implementations using fast fourier transforms (FFT) for the cases of interest in this work. The recursive implementation of a class of matched filters for enhancing image signal to noise ratio is described. Test patterns are used to illustrate the filtering operations. The application of the techniques to radiographic images of metallic structures is demonstrated through several examples.

  2. Radiographic inspection on offshore platforms

    International Nuclear Information System (INIS)

    Soares, Sergio Damasceno; Sperandio, Augusto Gasparoni

    1994-01-01

    One of the great challenges for non-destructive inspection is on offshore platforms, where safety is a critical issue. Inspection by gammagraphy is practically forbidden on the platform deck due to problems to personnel safety and radiological protection. Ir-192 sources are used and the risk of an accident with loss of radioisotope must be considered. It is unfeasible to use gammagraphy, because in case of an accident the rapid evacuation from the platform would be impossible. This problem does not occur when X-ray equipment is used as the radiation source. The limited practicality and portability of the X-ray equipment have prevented its use as a replacement for the gammagraphy. This paper presents the preliminary tests to see the viable use of radiographic tests with constant potential on offshore platforms. (author). 2 refs., 1 fig., 2 tabs, 3 photos

  3. Radiographic evaluation of osteosynthesis

    International Nuclear Information System (INIS)

    Mueller-Miny, H.; Erlemann, R.; Roos, N.; Peters, P.E.; Baranowski, D.

    1991-01-01

    Surgeons, orthopedic surgeons, and neurosurgeons employ a wide variety of different osteosynthetic devices in the treatment of fractures and in spinal surgery. In order to assess these instruments correctly, the radiologist should be aware of their purpose and normal apperance. The complications should be identified, such as delayed union, pseudarthrosis, dislocation, device loosening, fracture of the device, osteomyelitis, and refracture. To evaluate the fixation device adequately two plain radiographs are mandatory. An normal fracture healing and the most commonly used fixation devices, the abnormalities of fracture healing and their complications are discussed. (orig.) [de

  4. Digitization of conventional radiographs

    International Nuclear Information System (INIS)

    Wenz, W.; Buitrago-Tellez, C.; Blum, U.; Hauenstein, K.H.; Gufler, H.; Meyer, E.; Ruediger, K.

    1992-01-01

    The diagnostic value of a digitization system for analogue films based on a charge-coupled-device (CCD) scanner with adjustable resolution of 2.5 or 5 lp/mm was assessed. Some 110 skeletal radiographs, 50 contrast studies, including 25 of patients with Crohn's disease, and 70 abdominal plain films before and after successful lithotripsy for renal stones were digitized. Receiver operating characteristic (ROC) studies showed improved detection of cortical and trabecular defects with contrast-optimized digitized films. Edge enhancement algorithms yielded no additional information. Inflammatory lesions of Crohn's disease were detected equally well by conventional films and digitized images. A statistically significant improvement (p [de

  5. Radiographic scanning agent

    International Nuclear Information System (INIS)

    Bevan, J.A.

    1983-01-01

    This invention relates to radiodiagnostic agents and more particularly to a composition and method for preparing a highly effective technetium-99m-based bone scanning agent. One deficiency of x-ray examination is the inability of that technique to detect skeletal metastases in their incipient stages. It has been discovered that the methanehydroxydiphosphonate bone mineral-seeking agent is unique in that it provides the dual benefits of sharp radiographic imaging and excellent lesion detection when used with technetium-99m. This agent can also be used with technetium-99m for detecting soft tissue calcification in the manner of the inorganic phosphate radiodiagnostic agents

  6. Radiographic film digitizing devices

    International Nuclear Information System (INIS)

    McFee, W.H.

    1988-01-01

    Until recently, all film digitizing devices for use with teleradiology or picture archiving and communication systems used a video camera to capture an image of the radiograph for subsequent digitization. The development of film digitizers that use a laser beam to scan the film represents a significant advancement in digital technology, resulting in improved image quality compared with video scanners. This paper discusses differences in resolution, efficiency, reliability, and the cost between these two types of devices. The results of a modified receiver operating characteristic comparison study of a video scanner and a laser scanner manufactured by the same company are also discussed

  7. Hydrodynamics of Turning Flocks

    OpenAIRE

    Yang, Xingbo; Marchetti, M. Cristina

    2014-01-01

    We present a hydrodynamic model of flocking that generalizes the familiar Toner-Tu equations to incorporate turning inertia of well-polarized flocks. The continuum equations controlled by only two dimensionless parameters, orientational inertia and alignment strength, are derived by coarse graining the inertial spin model recently proposed by Cavagna et al. The interplay between orientational inertia and bend elasticity of the flock yields anisotropic spin waves that mediate the propagation o...

  8. Hydrodynamics of insect spermatozoa

    Science.gov (United States)

    Pak, On Shun; Lauga, Eric

    2010-11-01

    Microorganism motility plays important roles in many biological processes including reproduction. Many microorganisms propel themselves by propagating traveling waves along their flagella. Depending on the species, propagation of planar waves (e.g. Ceratium) and helical waves (e.g. Trichomonas) were observed in eukaryotic flagellar motion, and hydrodynamic models for both were proposed in the past. However, the motility of insect spermatozoa remains largely unexplored. An interesting morphological feature of such cells, first observed in Tenebrio molitor and Bacillus rossius, is the double helical deformation pattern along the flagella, which is characterized by the presence of two superimposed helical flagellar waves (one with a large amplitude and low frequency, and the other with a small amplitude and high frequency). Here we present the first hydrodynamic investigation of the locomotion of insect spermatozoa. The swimming kinematics, trajectories and hydrodynamic efficiency of the swimmer are computed based on the prescribed double helical deformation pattern. We then compare our theoretical predictions with experimental measurements, and explore the dependence of the swimming performance on the geometric and dynamical parameters.

  9. An introduction to relativistic hydrodynamics

    Energy Technology Data Exchange (ETDEWEB)

    Font, Jose A [Departamento de AstronomIa y AstrofIsica, Universidad de Valencia, Dr. Moliner 50, 46100 Burjassot (Valencia) (Spain)

    2007-11-15

    We review formulations of the equations of (inviscid) general relativistic hydrodynamics and (ideal) magnetohydrodynamics, along with methods for their numerical solution. Both systems can be cast as first-order, hyperbolic systems of conservation laws, following the explicit choice of an Eulerian observer and suitable fluid and magnetic field variables. During the last fifteen years, the so-called (upwind) high-resolution shock-capturing schemes based on Riemann solvers have been successfully extended from classical to relativistic fluid dynamics, both special and general. Nowadays, general relativistic hydrodynamical simulations in relativistic astrophysics are routinely performed, particularly within the test-fluid approximation but also for dynamical spacetimes. While such advances also hold true in the case of the MHD equations, the astrophysical applications investigated so far are still limited, yet the field is bound to witness major developments in the near future. The article also presents a brief overview of numerical techniques, providing state-of-the-art examples of their applicability to general relativistic fluids and magneto-fluids in characteristic scenarios of relativistic astrophysics.

  10. Inducer Hydrodynamic Load Measurement Devices

    Science.gov (United States)

    Skelley, Stephen E.; Zoladz, Thomas F.

    2002-01-01

    Marshall Space Flight Center (MSFC) has demonstrated two measurement devices for sensing and resolving the hydrodynamic loads on fluid machinery. The first - a derivative of the six component wind tunnel balance - senses the forces and moments on the rotating device through a weakened shaft section instrumented with a series of strain gauges. This "rotating balance" was designed to directly measure the steady and unsteady hydrodynamic loads on an inducer, thereby defining both the amplitude and frequency content associated with operating in various cavitation modes. The second device - a high frequency response pressure transducer surface mounted on a rotating component - was merely an extension of existing technology for application in water. MSFC has recently completed experimental evaluations of both the rotating balance and surface-mount transducers in a water test loop. The measurement bandwidth of the rotating balance was severely limited by the relative flexibility of the device itself, resulting in an unexpectedly low structural bending mode and invalidating the higher frequency response data. Despite these limitations, measurements confirmed that the integrated loads on the four-bladed inducer respond to both cavitation intensity and cavitation phenomena. Likewise, the surface-mount pressure transducers were subjected to a range of temperatures and flow conditions in a non-rotating environment to record bias shifts and transfer functions between the transducers and a reference device. The pressure transducer static performance was within manufacturer's specifications and dynamic response accurately followed that of the reference.

  11. Fluctuating hydrodynamics for ionic liquids

    Energy Technology Data Exchange (ETDEWEB)

    Lazaridis, Konstantinos [Department of Mathematics and Statistics, Washington State University, Pullman, 99163 (United States); Wickham, Logan [Department of Computer Science, Washington State University, Richland, 99354 (United States); Voulgarakis, Nikolaos, E-mail: n.voulgarakis@wsu.edu [Department of Mathematics and Statistics, Washington State University, Pullman, 99163 (United States)

    2017-04-25

    We present a mean-field fluctuating hydrodynamics (FHD) method for studying the structural and transport properties of ionic liquids in bulk and near electrified surfaces. The free energy of the system consists of two competing terms: (1) a Landau–Lifshitz functional that models the spontaneous separation of the ionic groups, and (2) the standard mean-field electrostatic interaction between the ions in the liquid. The numerical approach used to solve the resulting FHD-Poisson equations is very efficient and models thermal fluctuations with remarkable accuracy. Such density fluctuations are sufficiently strong to excite the experimentally observed spontaneous formation of liquid nano-domains. Statistical analysis of our simulations provides quantitative information about the properties of ionic liquids, such as the mixing quality, stability, and the size of the nano-domains. Our model, thus, can be adequately parameterized by directly comparing our prediction with experimental measurements and all-atom simulations. Conclusively, this work can serve as a practical mathematical tool for testing various theories and designing more efficient mixtures of ionic liquids. - Highlights: • A new fluctuating hydrodynamics method for ionic liquids. • Description of ionic liquid morphology in bulk and near electrified surfaces. • Direct comparison with experimental measurements.

  12. Interpreting radiographs. 4. The carpus

    International Nuclear Information System (INIS)

    Burguez, P.N.

    1984-01-01

    The complexity of the carpus which has three major joints, seven or eight carpal bones and five adjacent bones, each of which articulates with one or more of the carpal elements, necessitates good quality radiographs for definitive radiographic interpretation may be extremely difficult because of the disparity between radiographic changes and obvious clinical signs and, therefore, must be discussed in the light of a thorough clinical assessment

  13. Radiographer interpretation of trauma radiographs: Issues for radiography education providers

    International Nuclear Information System (INIS)

    Hardy, Maryann; Snaith, Beverly

    2009-01-01

    Background: The role of radiographers with respect to image interpretation within clinical practice is well recognised. It is the expectation of the professional, regulatory and academic bodies that upon qualification, radiographers will possess image interpretation skills. Additionally, The College of Radiographers has asserted that its aspiration is for all radiographers to be able to provide an immediate written interpretation on skeletal trauma radiographs by 2010. This paper explores the readiness of radiography education programmes in the UK to deliver this expectation. Method: A postal questionnaire was distributed to 25 Higher Education Institutions in the UK (including Northern Ireland) that provided pre-registration radiography education as identified from the Society and College of Radiographers register. Information was sought relating to the type of image interpretation education delivered at pre- and post-registration levels; the anatomical range of image interpretation education; and education delivery styles. Results: A total of 19 responses (n = 19/25; 76.0%) were received. Image interpretation education was included as part of all radiographer pre-registration programmes and offered at post-registration level at 12 academic centres (n = 12/19; 63.2%). The anatomical areas and educational delivery methods varied across institutions. Conclusion: Radiography education providers have embraced the need for image interpretation education within both pre- and post-registration radiography programmes. As a result, UK education programmes are able to meet the 2010 College of Radiographers aspiration.

  14. Titan's hydrodynamically escaping atmosphere

    Science.gov (United States)

    Strobel, Darrell F.

    2008-02-01

    The upper atmosphere of Titan is currently losing mass at a rate ˜(4-5)×10 amus, by hydrodynamic escape as a high density, slow outward expansion driven principally by solar UV heating by CH 4 absorption. The hydrodynamic mass loss is essentially CH 4 and H 2 escape. Their combined escape rates are restricted by power limitations from attaining their limiting rates (and limiting fluxes). Hence they must exhibit gravitational diffusive separation in the upper atmosphere with increasing mixing ratios to eventually become major constituents in the exosphere. A theoretical model with solar EUV heating by N 2 absorption balanced by HCN rotational line cooling in the upper thermosphere yields densities and temperatures consistent with the Huygens Atmospheric Science Investigation (HASI) data [Fulchignoni, M., and 42 colleagues, 2005. Nature 438, 785-791], with a peak temperature of ˜185-190 K between 3500-3550 km. This model implies hydrodynamic escape rates of ˜2×10 CHs and 5×10 Hs, or some other combination with a higher H 2 escape flux, much closer to its limiting value, at the expense of a slightly lower CH 4 escape rate. Nonthermal escape processes are not required to account for the loss rates of CH 4 and H 2, inferred by the Cassini Ion Neutral Mass Spectrometer (INMS) measurements [Yelle, R.V., Borggren, N., de la Haye, V., Kasprzak, W.T., Niemann, H.B., Müller-Wodarg, I., Waite Jr., J.H., 2006. Icarus 182, 567-576].

  15. Radiographically detectable intracortical porosity

    International Nuclear Information System (INIS)

    Meema, H.E.

    1986-01-01

    Since the measurement of intracortical resorptive spaces by histologic methods is difficult and very few data are available in normal humans, we have measured their lengths and widths and calculated the intracortical porosity in metacarpals and phalanges of 79 normal women and 69 normal men, using fine-detail radiographs of the hands and a computerized semi-automatic image analysis system (Zeiss MOP-3), this being the first study of this kind. Several methodological problems were solved satisfactorily, and the results of this study could serve as a data bank for further investigations concerned with intracortical resorption. Significant differences were found between age and sex versus several intracortical resorptive parameters; also significant correlations were found with age in some cases. Normal intracortical porosity was found to be about three times greater in the proximal phalanges than in the metacarpals. It is concluded that this methodology could be used for further studies of intracortical resorption in osteoporosis and other metabolic bone diseases. (orig.)

  16. Odontogenic keratocyst radiographic features

    International Nuclear Information System (INIS)

    Nartey, N. O.; Saini, T.

    1990-01-01

    The clinical features often patients with odontogenic keratocysts were studied. One patient had Gorlin-GoJtz syndrome. A total of fourteen radiolucent lesions were observed on radiographic examination. All the fourteen lesions were diagnosed as odontogenic keratocyst after histopathclogical examination of biopsied tissue from the patients. The age at diagnosis ranged from 25-72 years with a mean age of 37.6 years. The male : female ratio was 2.3:1. Thirteen of these lesions occurred in the mandible, nine involved the mandibular third molar region. Involvement of the ramus of the mandible produced a sausage-shaped radiolucency. Cystic lesions which have been present for long periods of time showed scalloped margins, due to the regional resorption of the surrounding bone. The bony ledges present on the cortical bones simulated multilocular appearance in such cases. It was also observed that the lesions in older individuals perforated the cortical plates rather than eliciting a periostally induced bony expansion. (author)

  17. A radiographic examination system

    International Nuclear Information System (INIS)

    Cable, A.P.; Cable, W.S.

    1983-01-01

    A system for performing radiographic examination, particularly of large items such as international container units is disclosed. The system is formed as an installation comprising housings for respective linear accelerators transmitting a beam of radiation across the path of a conveyor along which the units can be displaced continuously or incrementally. On either end of the installation are container handling areas including roller conveyors with drag chains and transverse manipulators, and the whole installation is secured within automatically operated doors which seal the high energy region when a container on the conveyor is being subjected to examination. The radiation transmitted through a container is detected in a detector system incorporating a fluoroscopic screen light output from which is detected in a camera system such as a television camera, and transmitted as coded pulsed signals by a coding transfer unit to display screens where an image of the transmitted information can be displayed and/or recorded for further use. (author)

  18. Radiographic contrast media

    International Nuclear Information System (INIS)

    Golman, K.; Holtz, E.; Almen, T.

    1987-01-01

    Contrast media are used in diagnostic radiology to enhance the X-ray attenuation between a body structure of interest and the surrounding tissue. A detail becomes perceptible on a roentgenogram only when its contrast exceeds a minimum value in relation to the background. Small areas of interest must have higher contrast than the background. The contrast effect depends on concentration of the contrast media with the body. A high contrast media concentration difference thus gives rise to more morphological details in the radiographs. Contrast media can be divided into negative contrast media such as air and gas which attenuate X-rays less than the body tissues, and positive contrast materials which attenuate X-rays more than the body tissues. The positive contrast media all contain either iodine (atomic number 53) or barium (atomic number 56) and can be divided into water-insoluble and water-soluble contrast media

  19. How to fake hydrodynamic signals

    Energy Technology Data Exchange (ETDEWEB)

    Romatschke, Paul [Department of Physics, 390 UCB, University of Colorado at Boulder, Boulder, CO (United States); Center for Theory of Quantum Matter, University of Colorado, Boulder, CO 80309 (United States)

    2016-12-15

    Flow signatures in experimental data from relativistic ion collisions, are usually interpreted as a fingerprint of the presence of a hydrodynamic phase during the evolution of these systems. I review some theoretical ideas to ‘fake’ this hydrodynamic behavior in p+A and A+A collisions. I find that transverse flow and femtoscopic measurements can easily be forged through non-hydrodynamic evolution, while large elliptic flow requires some non-vanishing interactions in the hot phase.

  20. Modeling hydrodynamic cavitation

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, P.S.; Pandit, A.B. [Mumbai Univ. (India). Chemical Engineering Div.

    1999-12-01

    Cavitation as a source and method of energy input for chemical processing is increasingly studied due to its ability to generate localized high temperatures and pressures under nearly ambient conditions. Compared to cavitation generated by ultrasound, hydrodynamic cavitation has been proved to be a very energy-efficient alternative. A simple and unified model has been developed to study the cavitation phenomena in hydraulic systems with emphasis on the venturi tube and high-speed homogenizer. The model has been found to be satisfactory in explaining the effect of operating variables and equipment geometry on two different modes of cavitation generation qualitatively and in some cases quantitatively. (orig.)

  1. Hydrodynamics of Ship Propellers

    DEFF Research Database (Denmark)

    Breslin, John P.; Andersen, Poul

    This book deals with flows over propellers operating behind ships, and the hydrodynamic forces and moments which the propeller generates on the shaft and on the ship hull.The first part of the text is devoted to fundamentals of the flow about hydrofoil sections (with and without cavitation...... of an intermittently cavitating propeller in a wake and the pressures and forces it exerts on the shaft and on the ship hull is examined. A final chapter discusses the optimization of efficiency of compound propulsors. The authors have taken care to clearly describe physical concepts and mathematical steps. Appendices...

  2. Foundations of radiation hydrodynamics

    CERN Document Server

    Mihalas, Dimitri

    1999-01-01

    Radiation hydrodynamics is a broad subject that cuts across many disciplines in physics and astronomy: fluid dynamics, thermodynamics, statistical mechanics, kinetic theory, and radiative transfer, among others. The theory developed in this book by two specialists in the field can be applied to the study of such diverse astrophysical phenomena as stellar winds, supernova explosions, and the initial phases of cosmic expansion, as well as the physics of laser fusion and reentry vehicles. As such, it provides students with the basic tools for research on radiating flows.Largely self-contained,

  3. Radiographic enhancement and analysis system

    International Nuclear Information System (INIS)

    Schlosser, M.S.

    1981-01-01

    Radiographic image enhancement and analysis techniques are discussed as they apply to nondestructive inspection. A system is described which has been developed to enhance and quantitatively evaluate radiographic images using digital computer techniques. Some examples of typical applications are also presented as an introduction to this new inspection technique. (author)

  4. Chesneys' radiographic imaging. 5. ed.

    International Nuclear Information System (INIS)

    Ball, J.; Price, T.

    1989-01-01

    This new edition of Chesney and Chesney: Radiographic Imaging has been completely written by two new authors. The book reflects the change in emphasis in radiology from photographic processes towards electronic imaging methods. There is new material on image intensifiers and television imaging, digital imaging and digital subtractions. Analyses of the various characteristics of, and defects in, images on radiographs, xeroradiographs and the television screen are included. The methods, equipment and materials used to record the cathode ray tube image are described and there is new material on the principles of alternative diagnostic imaging techniques such as ultrasound, computed tomography and radionuclide imaging which provide cathode ray tube images. The book is primarily for student radiographers studying for the Diploma of the College of Radiographers, but radiographers studying for postdiplomate qualifications such as the Higher Diploma (HDCR) will also find the book helpful. (author)

  5. Nanoscale hydrodynamics near solids

    Science.gov (United States)

    Camargo, Diego; de la Torre, J. A.; Duque-Zumajo, D.; Español, Pep; Delgado-Buscalioni, Rafael; Chejne, Farid

    2018-02-01

    Density Functional Theory (DFT) is a successful and well-established theory for the study of the structure of simple and complex fluids at equilibrium. The theory has been generalized to dynamical situations when the underlying dynamics is diffusive as in, for example, colloidal systems. However, there is no such a clear foundation for Dynamic DFT (DDFT) for the case of simple fluids in contact with solid walls. In this work, we derive DDFT for simple fluids by including not only the mass density field but also the momentum density field of the fluid. The standard projection operator method based on the Kawasaki-Gunton operator is used for deriving the equations for the average value of these fields. The solid is described as featureless under the assumption that all the internal degrees of freedom of the solid relax much faster than those of the fluid (solid elasticity is irrelevant). The fluid moves according to a set of non-local hydrodynamic equations that include explicitly the forces due to the solid. These forces are of two types, reversible forces emerging from the free energy density functional, and accounting for impenetrability of the solid, and irreversible forces that involve the velocity of both the fluid and the solid. These forces are localized in the vicinity of the solid surface. The resulting hydrodynamic equations should allow one to study dynamical regimes of simple fluids in contact with solid objects in isothermal situations.

  6. Anisotropic nonequilibrium hydrodynamic attractor

    Science.gov (United States)

    Strickland, Michael; Noronha, Jorge; Denicol, Gabriel S.

    2018-02-01

    We determine the dynamical attractors associated with anisotropic hydrodynamics (aHydro) and the DNMR equations for a 0 +1 d conformal system using kinetic theory in the relaxation time approximation. We compare our results to the nonequilibrium attractor obtained from the exact solution of the 0 +1 d conformal Boltzmann equation, the Navier-Stokes theory, and the second-order Mueller-Israel-Stewart theory. We demonstrate that the aHydro attractor equation resums an infinite number of terms in the inverse Reynolds number. The resulting resummed aHydro attractor possesses a positive longitudinal-to-transverse pressure ratio and is virtually indistinguishable from the exact attractor. This suggests that an optimized hydrodynamic treatment of kinetic theory involves a resummation not only in gradients (Knudsen number) but also in the inverse Reynolds number. We also demonstrate that the DNMR result provides a better approximation of the exact kinetic theory attractor than the Mueller-Israel-Stewart theory. Finally, we introduce a new method for obtaining approximate aHydro equations which relies solely on an expansion in the inverse Reynolds number. We then carry this expansion out to the third order, and compare these third-order results to the exact kinetic theory solution.

  7. Load responsive hydrodynamic bearing

    Science.gov (United States)

    Kalsi, Manmohan S.; Somogyi, Dezso; Dietle, Lannie L.

    2002-01-01

    A load responsive hydrodynamic bearing is provided in the form of a thrust bearing or journal bearing for supporting, guiding and lubricating a relatively rotatable member to minimize wear thereof responsive to relative rotation under severe load. In the space between spaced relatively rotatable members and in the presence of a liquid or grease lubricant, one or more continuous ring shaped integral generally circular bearing bodies each define at least one dynamic surface and a plurality of support regions. Each of the support regions defines a static surface which is oriented in generally opposed relation with the dynamic surface for contact with one of the relatively rotatable members. A plurality of flexing regions are defined by the generally circular body of the bearing and are integral with and located between adjacent support regions. Each of the flexing regions has a first beam-like element being connected by an integral flexible hinge with one of the support regions and a second beam-like element having an integral flexible hinge connection with an adjacent support region. A least one local weakening geometry of the flexing region is located intermediate the first and second beam-like elements. In response to application of load from one of the relatively rotatable elements to the bearing, the beam-like elements and the local weakening geometry become flexed, causing the dynamic surface to deform and establish a hydrodynamic geometry for wedging lubricant into the dynamic interface.

  8. Study of scattering in bi-dimensional neutron radiographic images

    International Nuclear Information System (INIS)

    Oliveira, K.A.M. de; Crispim, V.R.; Silva, F.C.

    2009-01-01

    The effect of neutron scattering frequently causes distortions in neutron radiographic images and, thus, reduces the quality. In this project, a type of filter, comprised of cadmium (a neutron absorber), was used in the form of a grid to correct this effect. This device generated image data in the discrete shadow bands of the absorber, components relative to neutron scattering on the test object and surroundings. Scattering image data processing, together with the original neutron radiographic image, resulted in a corrected image with improved edge delineation and, thus, greater definition in the neutron radiographic image of the test object. The objective of this study is to propose a theoretical/experimental methodology that is capable of eliminating the components relative to neutron scattering in neutron radiographic images, coming from the material that composes the test object and the materials that compose the surrounding area. (author)

  9. Advanced radiographic scanning, enhancement and electronic data storage

    International Nuclear Information System (INIS)

    Savoie, C.; Rivest, D.

    2003-01-01

    It is a well-known fact that radiographs deteriorate with time. Substantial cost is attributed to cataloguing and storage. To eliminate deterioration issues and save time retrieving radiographs, laser scanning techniques were developed in conjunction with viewing and enhancement software. This will allow radiographs to be successfully scanned and stored electronically for future reference. Todays radiographic laser scanners are capable Qf capturing images with an optical density of up to 4.1 at 256 grey levels and resolutions up to 4096 pixels per line. An industrial software interface was developed for the nondestructive testing industry so that, certain parameters such as scan resolution, number of scans, file format and location to be saved could be adjusted as needed. Once the radiographs have been scanned, the tiff images are stored, or retrieved into Radiance software (developed by Rivest Technologies Inc.), which will help to properly interpret the radiographs. Radiance was developed to allow the user to quickly view the radiographs correctness or enhance its defects for comparison and future evaluation. Radiance also allows the user to zoom, measure and annotate areas of interest. Physical cost associated with cataloguing, storing and retrieving radiographs can be eliminated. You can now successfully retrieve and view your radiographs from CD media or dedicated hard drive at will. For continuous searches and/or field access, dedicated hard drives controlled by a server would be the media of choice. All scanned radiographs will be archived to CD media (CD-R). Laser scanning with a proper acquisition interface and easy to use viewing software will permit a qualified user to identify areas of interest and share this information with his/her colleagues via e-mail or web data access. (author)

  10. Hydrodynamic Forces on Composite Structures

    Science.gov (United States)

    2014-06-01

    NAVAL POSTGRADUATE SCHOOL MONTEREY, CALIFORNIA THESIS Approved for public release; distribution is unlimited HYDRODYNAMIC ...Thesis 4. TITLE AND SUBTITLE HYDRODYNAMIC FORCES ON COMPOSITE STRUCTURES 5. FUNDING NUMBERS 6. AUTHOR(S) Scott C. Millhouse 7. PERFORMING...angles yields different free surface effects including vortices and the onset of cavitation . 14. SUBJECT TERMS Fluid structure interaction, FSI, finite

  11. Black brane entropy and hydrodynamics

    NARCIS (Netherlands)

    Booth, I.; Heller, M.P.; Spaliński, M.

    2010-01-01

    A generalization of entropy to near-equilibrium phenomena is provided by the notion of a hydrodynamic entropy current. Recent advances in holography have lead to the formulation of fluid-gravity duality, a remarkable connection between the hydrodynamics of certain strongly coupled media and dynamics

  12. Black brane entropy and hydrodynamics

    NARCIS (Netherlands)

    Booth, I.; Heller, M.P.; Spaliński, M.

    2011-01-01

    A generalization of entropy to near-equilibrium phenomena is provided by the notion of a hydrodynamic entropy current. Recent advances in holography have lead to the formulation of fluid-gravity duality, a remarkable connection between the hydrodynamics of certain strongly coupled media and dynamics

  13. A hydrodynamic formalism for Brownian systems

    International Nuclear Information System (INIS)

    Pina, E.; Rosales, M.A.

    1981-01-01

    A formal hydrodynamic approach to Brownian motion is presented and the corresponding equations are derived. Hydrodynamic quantities are expressed in terms of the physical variables characterizing the Brownian systems. Contact is made with the hydrodynamic model of Quantum Mechanics. (author)

  14. Radiographic scanner apparatus

    International Nuclear Information System (INIS)

    Wake, R.H.

    1980-01-01

    The preferred embodiment of this invention includes a hardware system, or processing means, which operates faster than software. Moreover the computer needed is less expensive and smaller. Radiographic scanner apparatus is described for measuring the intensity of radiation after passage through a planar region and for reconstructing a representation of the attenuation of radiation by the medium. There is a source which can be rotated, and detectors, the output from which forms a data line. The detectors are disposed opposite the planar region from the source to produce a succession of data lines corresponding to the succession of angular orientations of the source. There is a convolver means for convolving each of these data lines, with a filter function, and a means of processing the convolved data lines to create the representation of the radiation attenuation in the planar region. There is also apparatus to generate a succession of data lines indicating radiation attenuation along a determinable path with convolver means. (U.K.)

  15. Foundations of radiation hydrodynamics

    Science.gov (United States)

    Mihalas, D.; Mihalas, B. W.

    This book is the result of an attempt, over the past few years, to gather the basic tools required to do research on radiating flows in astrophysics. The microphysics of gases is discussed, taking into account the equation of state of a perfect gas, the first and second law of thermodynamics, the thermal properties of a perfect gas, the distribution function and Boltzmann's equation, the collision integral, the Maxwellian velocity distribution, Boltzmann's H-theorem, the time of relaxation, and aspects of classical statistical mechanics. Other subjects explored are related to the dynamics of ideal fluids, the dynamics of viscous and heat-conducting fluids, relativistic fluid flow, waves, shocks, winds, radiation and radiative transfer, the equations of radiation hydrodynamics, and radiating flows. Attention is given to small-amplitude disturbances, nonlinear flows, the interaction of radiation and matter, the solution of the transfer equation, acoustic waves, acoustic-gravity waves, basic concepts of special relativity, and equations of motion and energy.

  16. From TDHF to hydrodynamics

    International Nuclear Information System (INIS)

    Koehler, H.S.

    1983-01-01

    The Time-Dependent Hartree-Fock theory provides a microscopic approach to the scattering of heavy ions. Fundamental in this theory is a mean-(one-body) field. The calculation of this field from a two-body effective interaction makes the theory microscopic. Many-body effects are included by the Brueckner definition of this interaction; the reaction-matrix. In excited media it is in general complex allowing for decays. The imaginary part relates directly to the collision-term in a transport equation. We treat this term by the time-relaxation-method. This implies an extension of the TDHF-equation to include two-body collisions. Hydrodynamic equations are derived from this new equation. The solution of the two equations agree quantitatively for short-relaxation-times. Relaxation-times are calculated as a function of temperature. (orig.)

  17. Hydrodynamics of Peristaltic Propulsion

    Science.gov (United States)

    Athanassiadis, Athanasios; Hart, Douglas

    2014-11-01

    A curious class of animals called salps live in marine environments and self-propel by ejecting vortex rings much like jellyfish and squid. However, unlike other jetting creatures that siphon and eject water from one side of their body, salps produce vortex rings by pumping water through siphons on opposite ends of their hollow cylindrical bodies. In the simplest cases, it seems like some species of salp can successfully move by contracting just two siphons connected by an elastic body. When thought of as a chain of timed contractions, salp propulsion is reminiscent of peristaltic pumping applied to marine locomotion. Inspired by salps, we investigate the hydrodynamics of peristaltic propulsion, focusing on the scaling relationships that determine flow rate, thrust production, and energy usage in a model system. We discuss possible actuation methods for a model peristaltic vehicle, considering both the material and geometrical requirements for such a system.

  18. The radiographic image: A cultural artefact?

    International Nuclear Information System (INIS)

    Strudwick, Ruth M.

    2014-01-01

    This article looks at the role of the radiographic images produced by diagnostic radiographers. An ethnographic study of the workplace culture in one diagnostic imaging department was undertaken using participant observation for four months and semi-structured interviews with ten key informants. One of the key themes; that of the radiographic image as a cultural artefact, is explored in this article. The radiographic image is a cultural artefact which radiographers are protective of and take ownership of. Radiographers are conscious of the quality of their images and the images are an important aspect of their work. Radiographers take criticism of their images personally. The radiographic image is a record of the interaction that occurs between the radiographer and the patient. The way in which radiographic images are viewed, used and judged is an important aspect of the role of diagnostic radiographer

  19. Annual Scientific Report 2006 for Hydrodynamics and Radiation Hydrodynamics with Astrophysical Applications

    International Nuclear Information System (INIS)

    R. Paul Drake

    2007-01-01

    We report the ongoing work of our group in hydrodynamics and radiation hydrodynamics with astrophysical applications. During the period of the existing grant, we have carried out two types of experiments at the Omega laser. One set of experiments has studied radiatively collapsing shocks, obtaining data using a backlit pinhole with a 100 ps backlighter and beginning to develop the ability to look into the shock tube with optical or x-ray diagnostics. Other experiments have studied the deeply nonlinear development of the Rayleigh-Taylor (RT) instability from complex initial conditions, using dual-axis radiographic data with backlit pinholes and ungated detectors to complete the data set for a Ph.D. student. We lead a team that is developing a proposal for experiments at the National Ignition Facility and are involved in experiments at NIKE and LIL. All these experiments have applications to astrophysics, discussed in the corresponding papers. We assemble the targets for the experiments at Michigan, where we also prepare many of the simple components. We also have several projects underway in our laboratory involving our x-ray source. The above activities, in addition to a variety of data analysis and design projects, provide good experience for graduate and undergraduates students. In the process of doing this research we have built a research group that uses such work to train junior scientists

  20. Annual Report 2006 for Hydrodynamics and Radiation Hydrodynamics with Astrophysical Applications

    Energy Technology Data Exchange (ETDEWEB)

    R. Paul Drake

    2007-04-05

    We report the ongoing work of our group in hydrodynamics and radiation hydrodynamics with astrophysical applications. During the period of the existing grant, we have carried out two types of experiments at the Omega laser. One set of experiments has studied radiatively collapsing shocks, obtaining data using a backlit pinhole with a 100 ps backlighter and beginning to develop the ability to look into the shock tube with optical or x-ray diagnostics. Other experiments have studied the deeply nonlinear development of the Rayleigh-Taylor (RT) instability from complex initial conditions, using dual-axis radiographic data with backlit pinholes and ungated detectors to complete the data set for a Ph.D. student. We lead a team that is developing a proposal for experiments at the National Ignition Facility and are involved in experiments at NIKE and LIL. All these experiments have applications to astrophysics, discussed in the corresponding papers. We assemble the targets for the experiments at Michigan, where we also prepare many of the simple components. We also have several projects underway in our laboratory involving our x-ray source. The above activities, in addition to a variety of data analysis and design projects, provide good experience for graduate and undergraduates students. In the process of doing this research we have built a research group that uses such work to train junior scientists.

  1. Digitization of radiographic inspection for pipeline girth welded joints

    International Nuclear Information System (INIS)

    Uemura, Shimpei

    2016-01-01

    In radiographic inspection for the girth welded joints of natural gas pipeline, film radiographic testing (FRT) is applied presently in Japan. However, as of July 2016, the work of establishing JIS standard for radiographic inspection with digital detector is in progress. In order to provide users with the merit of digitization as soon as possible, the authors have developed NSDART (Nittetsu-Sumikin digital detector array technology) as a field X-ray inspection system for the girth welded joints of pipeline. This paper reports the required performances discussed in face of development of NSDART, selection of digital detector, and outline of NSDART, and shows part of the radiographic images acquired with NSDART. As required performances, the following were established: (1) required image quality for radiographic image, (2) identifiable minimum wire diameter of transmission meter, (3) density range of radiographic image and value of gradation meter, (4) spatial resolution via Duplex Wire, (5) X-ray generator, (6) real time performance, and (7) display for observing radiographic image. As for the selection of digital detector, flat panel detector was judged to be the most suitable, and its incorporation to NSDART was determined. NSDART devices are composed of a magnet-wheeled self-propelled imaging device, personal computer, controller, and externally installed display for judgment. (A.O.)

  2. Determining the hydrodynamic indices of contractions

    International Nuclear Information System (INIS)

    Blagov, Eh.E.

    2002-01-01

    The new dependences, making it possible only by measuring the flow rate and pressure drop on the contraction device (CD) with the known geometry, including the regulatory organ, in the non-crisis mode of the turbulent flow to calculate all the hydrodynamic indices of this device, including the pressure reduction in the jet contraction, are obtained. This simplifies and accelerates the CD hydraulic tests of all types. The new methodology for determining the cavitation factual start on the CD is proposed [ru

  3. Radiographic film cassette unloading apparatus

    International Nuclear Information System (INIS)

    Stievenart, E.F.; Plessers, H.S.; Neujens, G.J.

    1980-01-01

    Apparatus for unloading cassettes, containing exposed radiographic films, has means for unfastening the cassettes, an inclined pathway for gravity feeding and rotating feed members (rollers or belts) to propel the films into the processor. (UK)

  4. MINAC, portable high energy radiographic inspection system

    International Nuclear Information System (INIS)

    Lapides, M.E.; Schonberg, R.

    1985-01-01

    MINAC, a portable, high energy radiographic source (1) was recognized as a desired inspection device for nuclear generation plants during EPRI-sponsored studies of the late 1970s and rapidly transitioned from proof-of-principle (1978-1980) to field-proven hardware (1981-present date). The equipment has completed its second generation of configuration development (SHRINKAC), that has recently been used in the field for detection of pipe cracks. Important auxiliaries for image data processing and real-time, thick section radiography have been demonstrated in both laboratory and field situations. Finally, a 6 MeV accelerator alternate is in bench test. These significant developments have, and are expected to continue to upgrade the utility of radiographic inspection in power plant practice. This paper describes the development and experience with this modular system during the last three years

  5. Method for taking X radiographs

    International Nuclear Information System (INIS)

    Orth, G.

    1983-01-01

    The method is aimed at obtaining X radiographs of any human organ with the aid of an X-ray-shadowless radiation detector of a dose measuring device, which is arranged between patient and imaging system, and of a controlling microprocessor system, so that the image-forming parameters are automatically adjusted to the specific properties of the patient. This procedure minimices the efforts in preparing the radiograph and the radiation exposure of the patient

  6. Film holder for radiographing tubing

    International Nuclear Information System (INIS)

    Davis, E.V.; Foster, B.E.

    1976-01-01

    A film cassette is described which may be easily placed about tubing or piping and readily held in place while radiographic inspection is performed. A pair of precurved light-impervious semi-rigid plastic sheets, hinged at one edge, enclose sheet film together with any metallic foils or screens. Other edges are made light-tight with removable caps, and the entire unit is held securely about the object to be radiographed with a releasable fastener such as a strip of Velcro

  7. The radiographic manifestations of hypochondroplasia

    International Nuclear Information System (INIS)

    Heselson, N.G.; Cremin, B.J.; Beighton, P.

    1979-01-01

    Hypochrondroplasia is an inherited skeletal dysplasia that resembles achondroplasia in mild degree. Radiographic manifestations encountered in 12 affected individuals in South Africa include slight shortening of all segments of the tubular bones, moderate caudal diminution of the lumbar interpedicular distances, increased lumbar lordosis with cacral tilt and distal prolongation of the fibular. Hypochondroplasia can be distinguished from other osteochondrodystrophies such as achondroplasia, pseudo-achondroplasia and metaphyseal chondroplasia by the recognition of it clinical and radiographic manifestations. (author)

  8. Film holder for radiographing tubing

    Science.gov (United States)

    Davis, Earl V.; Foster, Billy E.

    1976-01-01

    A film cassette is provided which may be easily placed about tubing or piping and readily held in place while radiographic inspection is performed. A pair of precurved light-impervious semi-rigid plastic sheets, hinged at one edge, enclose sheet film together with any metallic foils or screens. Other edges are made light-tight with removable caps, and the entire unit is held securely about the object to be radiographed with a releasable fastener such as a strip of Velcro.

  9. Hydrodynamic cavitation for sonochemical effects.

    Science.gov (United States)

    Moholkar, V S; Kumar, P S; Pandit, A B

    1999-03-01

    A comparative study of hydrodynamic and acoustic cavitation has been made on the basis of numerical solutions of the Rayleigh-Plesset equation. The bubble/cavity behaviour has been studied under both acoustic and hydrodynamic cavitation conditions. The effect of varying pressure fields on the collapse of the cavity (sinusoidal for acoustic and linear for hydrodynamic) and also on the latter's dynamic behaviour has been studied. The variations of parameters such as initial cavity size, intensity of the acoustic field and irradiation frequency in the case of acoustic cavitation, and initial cavity size, final recovery pressure and time for pressure recovery in the case of hydrodynamic cavitation, have been found to have significant effects on cavity/bubble dynamics. The simulations reveal that the bubble/cavity collapsing behaviour in the case of hydrodynamic cavitation is accompanied by a large number of pressure pulses of relatively smaller magnitude, compared with just one or two pulses under acoustic cavitation. It has been shown that hydrodynamic cavitation offers greater control over operating parameters and the resultant cavitation intensity. Finally, a brief summary of the experimental results on the oxidation of aqueous KI solution with a hydrodynamic cavitation set-up is given which supports the conclusion of this numerical study. The methodology presented allows one to manipulate and optimise of specific process, either physical or chemical.

  10. Recent development of hydrodynamic modeling

    Science.gov (United States)

    Hirano, Tetsufumi

    2014-09-01

    In this talk, I give an overview of recent development in hydrodynamic modeling of high-energy nuclear collisions. First, I briefly discuss about current situation of hydrodynamic modeling by showing results from the integrated dynamical approach in which Monte-Carlo calculation of initial conditions, quark-gluon fluid dynamics and hadronic cascading are combined. In particular, I focus on rescattering effects of strange hadrons on final observables. Next I highlight three topics in recent development in hydrodynamic modeling. These include (1) medium response to jet propagation in di-jet asymmetric events, (2) causal hydrodynamic fluctuation and its application to Bjorken expansion and (3) chiral magnetic wave from anomalous hydrodynamic simulations. (1) Recent CMS data suggest the existence of QGP response to propagation of jets. To investigate this phenomenon, we solve hydrodynamic equations with source term which exhibits deposition of energy and momentum from jets. We find a large number of low momentum particles are emitted at large angle from jet axis. This gives a novel interpretation of the CMS data. (2) It has been claimed that a matter created even in p-p/p-A collisions may behave like a fluid. However, fluctuation effects would be important in such a small system. We formulate relativistic fluctuating hydrodynamics and apply it to Bjorken expansion. We found the final multiplicity fluctuates around the mean value even if initial condition is fixed. This effect is relatively important in peripheral A-A collisions and p-p/p-A collisions. (3) Anomalous transport of the quark-gluon fluid is predicted when extremely high magnetic field is applied. We investigate this possibility by solving anomalous hydrodynamic equations. We found the difference of the elliptic flow parameter between positive and negative particles appears due to the chiral magnetic wave. Finally, I provide some personal perspective of hydrodynamic modeling of high energy nuclear collisions

  11. STUDY OF EFFECTIVE TIME OF UNDILUTED FIXINGSOLUTIONS INLIGHTENING OF THE HIGH DENSITY PERIAPICAL RADIOGRAPHS

    Directory of Open Access Journals (Sweden)

    A ZAMANI NASER

    2003-12-01

    Full Text Available Introduction: Dental radiographs are occationally too dark because of different reasons such as over exposure, high concen-tration of developing solution and over development. Different chemicals are used to lighten these radiographs. In this research the undiluted fixed solution for the first time are tested and efficiency time of this solution in reducing the density of dark radiographs were evaluated. Method: Use of a dry mandible containing some teeth and 98 E speed periapical radiographs were prepared as foolow: A film wasexposed with 0.4 S... as positive control (ideal. 97 films were exposed with 1.8 S (dark and unreadable. Out of 97, one radiograph kept as positive control and remaining films prepared for study. All of radiographs developed and fixed with automatic processor in the same conditio. Out of 96 dark radiograph, 3 was used for pilot study and inserted in the undiluted fixing solution in different time. (2.5, 3 and 3.5 hrs. The result of pilot study showed that aii3 radiographs showed reductionin density and radiographs with her reduction time was closest to positive control for density and diognostic quality and radiograph with 2.5 hrs reduction time and 3.5 hre became darker and lighter as compared to positive control. The remaining 93 high density radiographs were divided into 3 groups, 31 in each group (group 1,2 and 3 first group 2.5 hrs, second 3 hrs and the third group 3.5 hrs were kept in undiluted fixed solution. for this, disposable glasses were used and in each glass a radiograph were inserted. The research time was spring and the temperature was about 2609 (without coolant. Evaluation of radiographs: For evaluation of radiographs 2 methods were used: First method used was: Densitometry: By this method the density of total lightened radiographs, positive control and negative control were determined. Another method was determined diagnostic quality of radiographs visually by radiologists, throng this way: Special

  12. SPECIAL RELATIVISTIC HYDRODYNAMICS WITH GRAVITATION

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Jai-chan [Department of Astronomy and Atmospheric Sciences, Kyungpook National University, Daegu (Korea, Republic of); Noh, Hyerim [Korea Astronomy and Space Science Institute, Daejon (Korea, Republic of)

    2016-12-20

    Special relativistic hydrodynamics with weak gravity has hitherto been unknown in the literature. Whether such an asymmetric combination is possible has been unclear. Here, the hydrodynamic equations with Poisson-type gravity, considering fully relativistic velocity and pressure under the weak gravity and the action-at-a-distance limit, are consistently derived from Einstein’s theory of general relativity. An analysis is made in the maximal slicing, where the Poisson’s equation becomes much simpler than our previous study in the zero-shear gauge. Also presented is the hydrodynamic equations in the first post-Newtonian approximation, now under the general hypersurface condition. Our formulation includes the anisotropic stress.

  13. Similarity flows in relativistic hydrodynamics

    International Nuclear Information System (INIS)

    Blaizot, J.P.; Ollitrault, J.Y.

    1986-01-01

    In ultra-relativistic heavy ion collisions, one expects in particular to observe a deconfinement transition leading to a formation of quark gluon plasma. In the framework of the hydrodynamic model, experimental signatures of such a plasma may be looked for as observable consequences of a first order transition on the evolution of the system. In most of the possible scenario, the phase transition is accompanied with discontinuities in the hydrodynamic flow, such as shock waves. The method presented in this paper has been developed to treat without too much numerical effort such discontinuous flow. It relies heavily on the use of similarity solutions of the hydrodynamic equations

  14. Radiographic appearance of the navicular bone in sound horses

    International Nuclear Information System (INIS)

    Kaser-Hotz, B.; Ueltschi, G.

    1992-01-01

    Radiographs of the navicular bone in 523 sound horses were reviewed. Detailed evaluation criteria were used. The incidence of radiographic changes and variations in normal horses were recorded. Results were tested for right-left limb difference and for age relationship. Variation in shape and bone structure was commonly seen in the navicular bone. Radiographic changes with an incidence of less than 2% included flexor cortex defects and calcification on the flexor surface. Fragments at the distal navicular bone border, calcification in the impar ligament and enthesiophytes at the proximal border were radiographic findings with an incidence of 2% to 10%. Abnormal canals at the distal border were found in 11% horses. Elongation of the lateral proximal extremity was commonly found. The mean width of the flexor cortex was 3.6 mm

  15. Radiographic inspection and densitometric evaluation of CP-5 reactor fuel

    International Nuclear Information System (INIS)

    Staroba, J.F.; Knoerzer, T.W.

    1978-02-01

    This report covers the radiographic and densitometric techniques used as part of a quality verification program for CP-5 reactor fuel by the Nondestructive Assay Section of the Special Materials Division. Other nondestructive tests used were ultrasonic and gamma-ray spectrometry. The main objectives were to perform a one-hundred percent radiographic inspection of the fuel tubes and to derive a quantitative relationship between fuel thickness and film density with the use of fabricated fuel step wedges. By the use of tangential x-ray techniques, measurements were made of fuel peaks or ''hot spots'' that protruded above the main fuel line. Other general problems in radiographic inspection and solutions for the upgrading of the total radiographic inspection program are also discussed

  16. Smoothed Particle Hydrodynamics Coupled with Radiation Transfer

    Science.gov (United States)

    Susa, Hajime

    2006-04-01

    We have constructed a brand-new radiation hydrodynamics solver based upon Smoothed Particle Hydrodynamics, which works on a parallel computer system. The code is designed to investigate the formation and evolution of first-generation objects at z ≳ 10, where the radiative feedback from various sources plays important roles. The code can compute the fraction of chemical species e, H+, H, H-, H2, and H+2 by by fully implicit time integration. It also can deal with multiple sources of ionizing radiation, as well as radiation at Lyman-Werner band. We compare the results for a few test calculations with the results of one-dimensional simulations, in which we find good agreements with each other. We also evaluate the speedup by parallelization, which is found to be almost ideal, as long as the number of sources is comparable to the number of processors.

  17. Radiographic examination of the equine head

    International Nuclear Information System (INIS)

    Park, R.D.

    1993-01-01

    Radiographic examinations of the equine head can be performed with portable x-ray machines. The views comprising the examination depend on the area of the head being examined. With a knowledge of radiographic anatomy and radiographic signs of disease, valuable diagnostic information can be obtained from the radiographic examination. In addition, the radiographic information can also be used to develop a prognosis and determine the most appropriate therapy

  18. Lotic Water Hydrodynamic Model

    Energy Technology Data Exchange (ETDEWEB)

    Judi, David Ryan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Tasseff, Byron Alexander [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-01-23

    Water-related natural disasters, for example, floods and droughts, are among the most frequent and costly natural hazards, both socially and economically. Many of these floods are a result of excess rainfall collecting in streams and rivers, and subsequently overtopping banks and flowing overland into urban environments. Floods can cause physical damage to critical infrastructure and present health risks through the spread of waterborne diseases. Los Alamos National Laboratory (LANL) has developed Lotic, a state-of-the-art surface water hydrodynamic model, to simulate propagation of flood waves originating from a variety of events. Lotic is a two-dimensional (2D) flood model that has been used primarily for simulations in which overland water flows are characterized by movement in two dimensions, such as flood waves expected from rainfall-runoff events, storm surge, and tsunamis. In 2013, LANL developers enhanced Lotic through several development efforts. These developments included enhancements to the 2D simulation engine, including numerical formulation, computational efficiency developments, and visualization. Stakeholders can use simulation results to estimate infrastructure damage and cascading consequences within other sets of infrastructure, as well as to inform the development of flood mitigation strategies.

  19. Hydrodynamics of rotating superfluids

    International Nuclear Information System (INIS)

    Chandler, E.A.

    1981-01-01

    In this thesis, a coarse grained hydrodynamics is developed from the exact description of Tkachenko. To account for the dynamics of the vortex lattice, the macroscopic vortex displacement field is treated as an independent degree of freedom. The conserved energy is written in terms of the coarse-grained normal fluid, superfluid, and vortex velocities and includes an elastic energy associated with deformations of the vortex lattice. Equations of motion consistent with the conservation of energy, entropy and vorticity and containing mutual friction terms arising from microscopic interactions between normal fluid excitations and the vortex lines are derived. When the vortex velocity is eliminated from the damping terms, this system of equations becomes essentially that of BK with added elastic terms in the momentum stress tensor and energy current. The dispersion relation and damping of the first and second sound modes and the two transverse modes sustained by the system are investigated. It is shown that mutual friction mixes the transverse modes of the normal and superfluid components and damps the transverse mode associated with the relative velocity of these components, making this wave evanescent in the plane perpendicular to the rotation axis. The wave associated with transverse motion of the total mass current is a generalized Tkachenko mode, whose dispersion relation reduces to that derived by Tkachenko wave when the wavevector lies in this plane

  20. Advanced in Macrostatistical Hydrodynamics

    International Nuclear Information System (INIS)

    Graham, A.L.; Tetlow, N.; Abbott, J.R.; Mondy, L.S.; Brenner, H.

    1993-01-01

    An overview is presented of research that focuses on slow flows of suspensions in which colloidal and inertial effects are negligibly small (Macrostatistical Hydrodynamics). First, we describe nuclear magnetic resonance imaging experiments to quantitatively measure particle migration occurring in concentrated suspensions undergoing a flow with a nonuniform shear rate. These experiments address the issue of how the flow field affects the microstructure of suspensions. In order to understand the local viscosity in a suspension with such a flow-induced, spatially varying concentration, one must know how the viscosity of a homogeneous suspension depends on such variables as solids concentration and particle orientation. We suggest the technique of falling ball viscometry, using small balls, as a method to determine the effective viscosity of a suspension without affecting the original microstructure significantly. We also describe data from experiments in which the detailed fluctuations of a falling ball's velocity indicate the noncontinuum nature of the suspension and may lead to more insights into the effects of suspension microstructure on macroscopic properties. Finally, we briefly describe other experiments that can be performed in quiescent suspensions (in contrast to the use of conventional shear rotational viscometers) in order to learn more about the microstructure and boundary effects in concentrated suspensions

  1. Reproductive health of male radiographers

    International Nuclear Information System (INIS)

    Shakhatreh, Farouk M.

    2001-01-01

    To compare certain reproductive health problems reported in 2 groups of males, one of which was exposed to x-ray radiation (radiographers) and the other group that was not exposed to x-ray radiation. The reproductive health problems were miscarriage, congenital anomalies, still births and infertility. Two groups of men were selected (90 in each group). The first group consisted of radiographers and the other groups consisted of men not exposed to x-ray radiation. The 2 groups were matched for age and source. Relative risk, attributable risk percentage and level of significance were calculated. Incidence rate of reproductive health problems was increasing with the increase in duration of exposure to x-ray radiation ranging between 17% (for those exposed for 1-5 years) to 91% (for those exposed for more than 15 years). There were significant associations between exposure to radiation and miscarriage (relative risk = 1.67, attributable risk percentage = 40%), congenital anomalies (relative risk = 10, attributable risk percentage 90%), still birth (relative risk = 7, attributable risk percentage = 86%), and infertility (relative risk = 4.5, attributable risk = 78%). The incidence rates of reproductive health problems reported by male radiographers were significantly higher than that reported by the non exposed group and higher than the incidence rates reported in community-based studies in Jordan. The incidence rates of fetal death (miscarriage and stillbirth together) and infertility reported by our radiographers were higher than had been reported by the British radiographers. An immediate plan of action is needed to protect our radiographers. Further studies are needed in this field taking into account all extraneous variables that may affect the reproductive health of radiographers. (author)

  2. Hydrodynamics of electrons in graphene

    Science.gov (United States)

    Lucas, Andrew; Chung Fong, Kin

    2018-02-01

    Generic interacting many-body quantum systems are believed to behave as classical fluids on long time and length scales. Due to rapid progress in growing exceptionally pure crystals, we are now able to experimentally observe this collective motion of electrons in solid-state systems, including graphene. We present a review of recent progress in understanding the hydrodynamic limit of electronic motion in graphene, written for physicists from diverse communities. We begin by discussing the ‘phase diagram’ of graphene, and the inevitable presence of impurities and phonons in experimental systems. We derive hydrodynamics, both from a phenomenological perspective and using kinetic theory. We then describe how hydrodynamic electron flow is visible in electronic transport measurements. Although we focus on graphene in this review, the broader framework naturally generalizes to other materials. We assume only basic knowledge of condensed matter physics, and no prior knowledge of hydrodynamics.

  3. Comparison between sodium hypochlorite and copper sulfate reducer in lightening of overexposed working length radiographs

    Directory of Open Access Journals (Sweden)

    Fatemeh Ezoddini Ardakani

    2015-12-01

    Full Text Available Objectives: The aims of this study were to test whether lightening of the overexposed radiographs improve determination of endodontic files length and whether lightened radiographs are comparable with ideally exposed radiographs. Material and Methods: Four dried human skull coated with soft tissue-equivalent wax used for exposing radiographs of the upper molars. First, the endodontic file was placed in full length of the root and four series of radiographs obtained. The time to expose the first series was unchanged (standard group but increased for the other three series.  Two series of overexposed radiographs set as test groups (one lightened with copper sulfate reducer and the other lightened with sodium hypochlorite and one series set as control group. Then the endodontic file placed 2mm short in the root and four series of radiographs obtained like the former. A viewer evaluated radiographs. ROC curves were obtained and areas under the curves were calculated. Sensitivity, specificity and Cohen’s kappa was calculated. Results: The average area under ROC curves was 1, 0.995,1 and 0.643 for the standard, Copper sulfate, sodium hypochlorite and the control group, respectively. Sodium hypochlorite show a better performance in terms of sensitivity and specificity compared to Copper sulfate. Differences between the test radiographs and standard and control radiographs were significant (p

  4. Analytic approaches to relativistic hydrodynamics

    Energy Technology Data Exchange (ETDEWEB)

    Hatta, Yoshitaka

    2016-12-15

    I summarize our recent work towards finding and utilizing analytic solutions of relativistic hydrodynamic. In the first part I discuss various exact solutions of the second-order conformal hydrodynamics. In the second part I compute flow harmonics v{sub n} analytically using the anisotropically deformed Gubser flow and discuss its dependence on n, p{sub T}, viscosity, the chemical potential and the charge.

  5. Hydrodynamic aspects of flotation separation

    Directory of Open Access Journals (Sweden)

    Peleka Efrosyni N.

    2016-01-01

    Full Text Available Flotation separation is mainly used for removing particulates from aqueous dispersions. It is widely used for ore beneficiation and recovering valuable materials. This paper reviews the hydrodynamics of flotation separations and comments on selected recent publications. Units are distinguished as cells of ideal and non-ideal flow. A brief introduction to hydrodynamics is included to explain an original study of the hybrid flotation-microfiltration cell, effective for heavy metal ion removal.

  6. An introduction to astrophysical hydrodynamics

    CERN Document Server

    Shore, Steven N

    1992-01-01

    This book is an introduction to astrophysical hydrodynamics for both astronomy and physics students. It provides a comprehensive and unified view of the general problems associated with fluids in a cosmic context, with a discussion of fluid dynamics and plasma physics. It is the only book on hydrodynamics that addresses the astrophysical context. Researchers and students will find this work to be an exceptional reference. Contents include chapters on irrotational and rotational flows, turbulence, magnetohydrodynamics, and instabilities.

  7. A radiographic study of mental foramen in intraoral radiographs

    International Nuclear Information System (INIS)

    Sohn, Jeong Ick; Choi, Karp Shik

    1995-01-01

    The purpose of this study was to evaluate the position and shape of mental foramen in periapical radiographs. For this study, periapical radiographs of premolar areas were obtained from the 200 adults. Accordingly, the positional and shape changes of mental foramen were evaluated. The authors obtained radiographs according to changes in radiation beam direction in periapical radiographs of premolar areas, and then evaluated the positional and shape changes of mental foramen. The following results were obtained: 1. Shapes of mental foramen were observed elliptical (34.3%), round or oval (28.0%), unidentified (25.5%) and diffuse (12.2%) type in descending order of frequency. 2, Horizontal positions of mental foramen were most frequently observed at the 2nd premolar area (55.3%), the area between the 1st premolar and 2nd premolar (39.6%), the area between the 2nd premolar and 1st molar (3.4%), the 1st premolar area (1.0%), the area between the canine and 1st premolar (0.7%) in descending order of frequency. 3. Vertical positions of mental foramen were most frequently observed at the inferior to apex (67.1%), and at apex (24.8%), overlap with apex (6.4%), superior to apex (1.7%) in descending order of frequency. 4. Shapes of mental foramen were more obviously observed at the upward 10 degree positioned periapical radiographs. And according to the changes of horizontal and vertical position, they were observed similar to normally positioned periapical radiographs.

  8. Attitudes of radiographers to radiographer-led discharge: A survey

    International Nuclear Information System (INIS)

    Lumsden, Laura; Cosson, Philip

    2015-01-01

    Background: The traditional role of the Diagnostic Radiographer in image acquisition has gradually been extended through skill-mix, particularly to include abnormality detection. Aims: This research focused on the attitudes of Radiographers to Radiographer-led Discharge (RLD), where Radiographers discharge patients with minor injuries and perform tasks previously undertaken by Accident and Emergency staff. The effects of job role, hospital type, experience and whether RLD was used in the participant's trust were examined. Method: A multiple-indicator online questionnaire assessed attitudes to RLD. Snowball sampling was used with advertisement via emails, posters and cards, containing Quick Response (QR) codes. Statement responses were coded, with reverse coding for negative statements and total scores were calculated. A higher score represented a more positive attitude. Results: 101 questionnaires were completed (an estimated 30% response rate) and the mean total score was 84/115. 95% of participants supported radiographer involvement in abnormality detection, with 46.5% selecting RLD as the preferred system for minor injuries patients vs 48.5% preferring commenting alone. Discussion: Participants were positive about extending their role through RLD and felt confident in their image interpretation abilities, though expressed concern for the legal consequences of the role and adequate pay. Generalization of the results is limited due to the possible low response rate. Conclusion: Overall, participants demonstrated positive attitudes towards RLD but they also indicate the need for appropriate payment for any additional responsibility. These findings are promising for successful implementation of RLD, though larger-scale research including radiologists, business managers, A and E staff and patients would be beneficial. - Highlights: • 101 questionnaires were completed (an estimated 30% response rate). • 95% of participants supported radiographer involvement

  9. CALIBRATED HYDRODYNAMIC MODEL

    Directory of Open Access Journals (Sweden)

    Sezar Gülbaz

    2015-01-01

    Full Text Available The land development and increase in urbanization in a watershed affect water quantityand water quality. On one hand, urbanization provokes the adjustment of geomorphicstructure of the streams, ultimately raises peak flow rate which causes flood; on theother hand, it diminishes water quality which results in an increase in Total SuspendedSolid (TSS. Consequently, sediment accumulation in downstream of urban areas isobserved which is not preferred for longer life of dams. In order to overcome thesediment accumulation problem in dams, the amount of TSS in streams and inwatersheds should be taken under control. Low Impact Development (LID is a BestManagement Practice (BMP which may be used for this purpose. It is a land planningand engineering design method which is applied in managing storm water runoff inorder to reduce flooding as well as simultaneously improve water quality. LID includestechniques to predict suspended solid loads in surface runoff generated over imperviousurban surfaces. In this study, the impact of LID-BMPs on surface runoff and TSS isinvestigated by employing a calibrated hydrodynamic model for Sazlidere Watershedwhich is located in Istanbul, Turkey. For this purpose, a calibrated hydrodynamicmodel was developed by using Environmental Protection Agency Storm WaterManagement Model (EPA SWMM. For model calibration and validation, we set up arain gauge and a flow meter into the field and obtain rainfall and flow rate data. Andthen, we select several LID types such as retention basins, vegetative swales andpermeable pavement and we obtain their influence on peak flow rate and pollutantbuildup and washoff for TSS. Consequently, we observe the possible effects ofLID on surface runoff and TSS in Sazlidere Watershed.

  10. Caries detection in dental radiographs

    International Nuclear Information System (INIS)

    Dunn, S.M.

    1987-01-01

    Caries, or the decay of teeth are difficult to automatically detect in dental radiographs because of the small area of the image that is occupied by the decay. Images of dental radiographs has distinct regions of homogeneous gray levels, and therefore naturally lead to a segmentation based automatic caries detection algorithm. This paper describes a method for caries detection based on a multiclass, area independent thresholding and segmenting scheme. This multiclass thresholding algorithm is an extension of the uniform error threshold, an area independent, distribution free thresholding method used for images of only two classes of objects. The authors first consider the problem of caries detection and the image features that characterize the presence of caries. Next, the uniform error threshold is reviewed, and the general multiclass uniform error threshold algorithm is presented. This algorithm is used to automatically detect caries in dental radiographs

  11. Interpretation and evaluation of radiograph

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    After digestion, the interpreter must interpreted and evaluate the image on film, usually many radiograph stuck in this step, if there is good density, so there are no problem. This is a final stage of radiography work and this work must be done by level two or three radiographer. This is a final stages before the radiographer give a result to their customer for further action. The good interpreter must know what kind of artifact, is this artifact are dangerous or not and others. In this chapter, the entire artifact that usually showed will be discussed briefly with the good illustration and picture to make the reader understand and know the type of artifact that exists.

  12. Industrial radiography on radiographic paper

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1977-11-01

    An investigation was performed to compare the quality of radiographic paper with that of X-ray film, after a review had been made of the rather scarce literature on the subject. The equipment used throughout the investigation is described, and characteristic curves for Agfa-Gevaert and Kodak papers exposed with different intensifying screens in the low and intermediate voltage range are reproduced. The relative speed, contrast and exposure latitude were computed from these curves. The quality of the radiographic image was checked on U/Al blocks and plates, Al and Fe blocks, and fiber-reinforced composites. Exposure charts for Al and Fe were made for various paper and screen combinations. Both the sharpness of the radiographic image as well as the influence of processing on speed and contrast were checked. Examples are given of the practical application of the paper for radiography of castings, weldings, solderings, assemblies, etc. (author)

  13. Sensitometric properties and image quality of radiographic film and paper

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1985-01-01

    When using X-ray film or radiographic paper for industrial applications one is interested in knowing not only their sensitometric properties (such as speed and contrast) but also the image quality obtainable with a particular brand of film or paper. Although standard methods for testing sensitometric properties and image quality separately are available, it is desirable to find a method by the use of which all the relevant properties could be tested together. The sensitometric properties are usually determined at constant kilovoltage and filtration at the X-ray tube, whereas the radiographic image quality is tested at different kilovoltages and for different material thicknesses

  14. Hydrodynamic escape from planetary atmospheres

    Science.gov (United States)

    Tian, Feng

    Hydrodynamic escape is an important process in the formation and evolution of planetary atmospheres. Due to the existence of a singularity point near the transonic point, it is difficult to find transonic steady state solutions by solving the time-independent hydrodynamic equations. In addition to that, most previous works assume that all energy driving the escape flow is deposited in one narrow layer. This assumption not only results in less accurate solutions to the hydrodynamic escape problem, but also makes it difficult to include other chemical and physical processes in the hydrodynamic escape models. In this work, a numerical model describing the transonic hydrodynamic escape from planetary atmospheres is developed. A robust solution technique is used to solve the time dependent hydrodynamic equations. The method has been validated in an isothermal atmosphere where an analytical solution is available. The hydrodynamic model is applied to 3 cases: hydrogen escape from small orbit extrasolar planets, hydrogen escape from a hydrogen rich early Earth's atmosphere, and nitrogen/methane escape from Pluto's atmosphere. Results of simulations on extrasolar planets are in good agreement with the observations of the transiting extrasolar planet HD209458b. Hydrodynamic escape of hydrogen from other hypothetical close-in extrasolar planets are simulated and the influence of hydrogen escape on the long-term evolution of these extrasolar planets are discussed. Simulations on early Earth suggest that hydrodynamic escape of hydrogen from a hydrogen rich early Earth's atmosphere is about two orders magnitude slower than the diffusion limited escape rate. A hydrogen rich early Earth's atmosphere could have been maintained by the balance between the hydrogen escape and the supply of hydrogen into the atmosphere by volcanic outgassing. Origin of life may have occurred in the organic soup ocean created by the efficient formation of prebiotic molecules in the hydrogen rich early

  15. Digital image analysis of NDT radiographs

    International Nuclear Information System (INIS)

    Graeme, W.A. Jr.; Eizember, A.C.; Douglass, J.

    1989-01-01

    Prior to the introduction of Charge Coupled Device (CCD) detectors the majority of image analysis performed on NDT radiographic images was done visually in the analog domain. While some film digitization was being performed, the process was often unable to capture all the usable information on the radiograph or was too time consuming. CCD technology now provides a method to digitize radiographic film images without losing the useful information captured in the original radiograph in a timely process. Incorporating that technology into a complete digital radiographic workstation allows analog radiographic information to be processed, providing additional information to the radiographer. Once in the digital domain, that data can be stored, and fused with radioscopic and other forms of digital data. The result is more productive analysis and management of radiographic inspection data. The principal function of the NDT Scan IV digital radiography system is the digitization, enhancement and storage of radiographic images

  16. Hydrodynamic Study Of Column Bioleaching Processes

    Directory of Open Access Journals (Sweden)

    Sadowski Zygmunt

    2015-06-01

    Full Text Available The modelling of flow leaching solution through the porous media has been considered. The heap bioleaching process can be tested using the column experimental equipment. This equipment was employed to the hydrodynamic studies of copper ore bioleaching. The copper ore (black shale ore with the support, inertial materials (glass small balls and polyethylene beads was used to the bioleaching tests. The packed beds were various composition, the ore/support ratio was changed. The correlation between the bed porosity and bioleaching kinetics, and copper recovery was investigated.

  17. Hydrodynamic Modeling of Santa Marta's Big Marsh

    International Nuclear Information System (INIS)

    Saldarriaga, Juan

    1991-01-01

    The ecological degradation of Santa Marta's Big Marsh and their next areas it has motivated the realization of diagnosis studies and design by several state and private entities. One of the recommended efforts for international advisory it was to develop an ecological model that allowed the handling of the water body and the economic test of alternative of solution to those ecological problems. The first part of a model of this type is in turn a model that simulates the movement of the water inside the marsh, that is to say, a hydrodynamic model. The realization of this was taken charge to the civil engineering department, on the part of Colciencias. This article contains a general explanation of the hydrodynamic pattern that this being developed by a professors group. The ecological causes are described and antecedent, the parts that conform the complex of the Santa Marta big Marsh The marsh modeling is made and it is explained in qualitative form the model type Hydrodynamic used

  18. Chest radiographic findings in neurotuberculosis without pulmonary signs and symptoms

    International Nuclear Information System (INIS)

    Aurangzeb, S.; Badshah, M.; Khan, B.R.S.

    2008-01-01

    To determine the chest radiographic findings in patients of adult neurotuberculosis, with no pulmonary signs and symptoms. A total of 100 patients fulfilling pre-defined criteria of neurotuberculosis were included. Chest radiographic (CXR) evidence of pulmonary TB was looked for in those patients and its frequency, pattern and association with the clinical grades at presentation was determined by using Chi-square test. Out of the 100 patients of neurotuberculosis, with no clinical evidence of pulmonary TB, radiographic evidence of pulmonary TB was seen in only 30% patients. The predominant patterns on CXR were apical infiltration (26.6%), military mottling (20%) and hilar enlargement (16.6%). Positive CXR was found in 16.7% patients in clinical grade I and 40% and 43.3% in patients in grade II and III respectively. There was a strong association of grade II and grade III with positive chest radiographic findings (p= 0.03). Patients of neurotuberculosis may have chest radiographic evidence of pulmonary TB even in the absence of pulmonary signs and symptoms at presentation. There is a strong association of clinical grade II and grade III with positive chest radiographic findings. (author)

  19. PACS influence the radiographer's work

    International Nuclear Information System (INIS)

    Fridell, Kent; Aspelin, Peter; Edgren, Lars; Lindskoeld, Lars; Lundberg, Nina

    2009-01-01

    Radiological departments are changing rapidly due to the implementation of digital images and PACS (Picture Archiving and Communication Systems). The introduction of new technology seems to dissolve boundaries between the professions in the work environment where the technology is introduced. This process tends to change the organization and its routines. The aim of this qualitative study is to explore changes in radiographers' work with regard to skills, work practice and technology. The study used open-ended interviews to explore the radiographers' perceptions of such changes, and to identify problems and solutions pertaining to work practice. Inspiration is taken from grounded theory to explain the changes in work that were found. Respondents were selected from a total of 133 potential participants as a theoretical or purposive sample. The changing trends within the professional role indicated that radiographers, as image producers, shifted their focus from the ability to set the optimal exposure parameters in order to obtain the optimal image for diagnosis to become expert in exposure parameters, projection techniques and diagnostic practice, having multifaceted skills, as being the jack of all trades. When implementing PACS there was an obvious change in image production. At the start there were visions of new routines, and therefore the radiographers became early adopters to the new technology; in practice the organization was stacked in old routines, as the routines were inflexible and PACS work was pushed into old work routines. Although inflexible, this does not mean that they cannot change, and obviously in 2006 new routines had been implemented making it possible for the radiographers in finding new ways for collaborating with colleagues. The new technology immediately created a vision of improved service to the clinicians. In order to optimize the service the radiographers developed an insight into the need for a more comprehensive change in work using

  20. Internet-accessible radiographic database of Vietnam War casualties for medical student education.

    Science.gov (United States)

    Critchley, Eric P; Smirniotopoulos, James G

    2003-04-01

    The purpose of this study was to determine the feasibility of archiving radiographic images from Vietnam era conflict casualties into a personal computer-based electronic database of text and images and displaying the data using an Internet-accessible database for preservation and educational purposes. Thirty-two patient cases were selected at random from a pool of 1,000 autopsy reports in which radiographs were available. A total of 74 radiographs from these cases were digitized using a commercial image scanner and then uploaded into an Internet accessible database. The quality of the digitized images was assessed by administering an image-based test to a group of 12 medical students. No statistically significant (p > 0.05) differences were found between test scores when using the original radiographs versus using the digitized radiographs on the Internet-accessible database. An Internet-accessible database is capable of effectively archiving Vietnam era casualty radiographs for educational purposes.

  1. Evaluation of the styloid process on digital panoramic radiographs

    International Nuclear Information System (INIS)

    More, Chandramani B; Asrani, Mukesh K

    2010-01-01

    The styloid process is an anatomical structure, whose clinical importance is not well understood. Proper clinical and radiographic evaluation can detect an elongated styloid process and calcification of the stylohyoid ligament. It has been reported that 2 – 28% of the general population show radiographic evidence of mineralization of a portion of the stylohyoid chain. The elongated styloid process may be symptomatic in many cases. Panoramic radiography is the best imaging modality to view the styloid process bilaterally. To assess the styloid process on digital panoramic radiographs. The study was conducted on 500 digital panoramic radiographs available in the archives of our department as soft copies. These radiographs were taken using a digital panoramic system. The radiographic length of the styloid process was measured on both sides using the measurement toolbars on the accompanying analysis software. For statistical analysis we used the unpaired t test, Chi-square test, and one-way ANOVA test, as necessary. The average length of the left styloid was 25.41 ± 6.32 mm and that of the right styloid was 25.53 ± 6.62 mm. The length of both styloids increased with age and males had longer styloids than females. Elongated styloids were present in 19.4% of the panoramic radiographs. Langlais type I elongated styloids and a partial calcification pattern were more common than others. Panoramic radiography is useful for detection of an elongated styloid process and / or ossification of the stylohyoid ligament in patients with or without symptoms, and helps avoid a misdiagnosis of tonsillar pain or pain of dental, pharyngeal, or muscular origin

  2. Evaluation of the styloid process on digital panoramic radiographs

    Directory of Open Access Journals (Sweden)

    More Chandramani

    2010-01-01

    Full Text Available Background: The styloid process is an anatomical structure, whose clinical importance is not well understood. Proper clinical and radiographic evaluation can detect an elongated styloid process and calcification of the stylohyoid ligament. It has been reported that 2 - 28% of the general population show radiographic evidence of mineralization of a portion of the stylohyoid chain. The elongated styloid process may be symptomatic in many cases. Panoramic radiography is the best imaging modality to view the styloid process bilaterally. Aim: To assess the styloid process on digital panoramic radiographs. Materials and Methods: The study was conducted on 500 digital panoramic radiographs available in the archives of our department as soft copies. These radiographs were taken using a digital panoramic system. The radiographic length of the styloid process was measured on both sides using the measurement toolbars on the accompanying analysis software. For statistical analysis we used the unpaired t test, Chi-square test, and one-way ANOVA test, as necessary. Results: The average length of the left styloid was 25.41 ± 6.32 mm and that of the right styloid was 25.53 ± 6.62 mm. The length of both styloids increased with age and males had longer styloids than females. Elongated styloids were present in 19.4% of the panoramic radiographs. Langlais type I elongated styloids and a partial calcification pattern were more common than others. Conclusion: Panoramic radiography is useful for detection of an elongated styloid process and / or ossification of the stylohyoid ligament in patients with or without symptoms, and helps avoid a misdiagnosis of tonsillar pain or pain of dental, pharyngeal, or muscular origin.

  3. Correlating intravenous radiographic contrast media reactions with the allergic profile

    International Nuclear Information System (INIS)

    Chua-Lim, A.; Enright, T.; Duda, E.; Lim, D.T.

    1987-01-01

    To determine the relevance of allergy as a predisposing factor in reactions to radiographic contrast media, the authors investigated the incidence of allergy among 100 randomly selected patients undergoing intravenous excretory urography and CT. The study population consisted of 50 reactors and 50 nonreactos to radiographic contrast media. All 100 subjects completed an allergy history, percutaneous allergy tests, and an in vitro specific IgE assay to common allergens. Thirty-four of 50 reactors had a positive allergy history, in contrast to 15 of 50 nonreactors (P < .001). Twenty-seven reactors had positive skin tests, in contrast to 12 of 50 nonreactors (P < .005). In vitro IgE assay results are pending. The results indicate that patients with positive histories or positive skin tests or both are at an increased risk for reactions to radiographic contrast media

  4. Chaotic hydrodynamics of fluidized beds

    Energy Technology Data Exchange (ETDEWEB)

    Van der Stappen, M.L.M. [Unit Process and Systems Engineering, Advanced Manufacturing Technology Group, Unilever Research Laboratorium, Vlaardingen (Netherlands)

    1996-12-31

    The major goals of this thesis are: (1) to develop and evaluate an analysis method based on techniques from non-linear chaos theory to characterize the nonlinear hydrodynamics of gas-solids fluidized beds quantitatively; and (2) to determine the dependence of the chaotic invariants on the operating conditions and investigate how the chaos analysis method can be profitably applied to improve scale-up and design of gas-solids fluidized bed reactors. Chaos theory is introduced in chapter 2 with emphasis on analysis techniques for (experimental) time series, known from literature at the start of this work (1990-1991). In chapter 3, the testing of existing and newly developed techniques on both model and fluidized bed data is described. This leads to the development of the chaos analysis method to analyze measured pressure fluctuations time series of a fluidized bed. Following, in chapter 4, this method is tested and all choices for the parameters are evaluated. The influence of the experimental parameters and external disturbances on the measurements and analysis results is discussed and quantified. The result is a chaos measurement and analysis protocol, which is further used in this work. In chapter 5, the applications to fluidized beds are discussed. It is shown that the entropy is a good measure for the characterization of the dynamical behavior of gas-solids bubbling/slugging fluidized beds. Entropy is applied to characterize the influence of the operating conditions, to assess regime transitions and to analyze dimensionless similar beds of different scale. Quantitative design correlations that relate entropy to the operating parameters (including the bed diameter) are described. Finally, it is discussed how the results of this work might be used in scaling up the chaotic dynamics of fluidized beds. The overall conclusions and outlook from this work are presented in chapter 6. 182 refs.

  5. Dimensions of defects determined by radiographical testing

    International Nuclear Information System (INIS)

    Oesterberg, J.

    Normally industrial radiography using x-rays or radionuclides gives information on the existence of defects in welds. These defects may in some instances be harmless, the size of the flaw is important. Radiography may be used for determining the thickness of the defect in many cases, by measuring the blackening of the photographic film used. The report gives a theoretical treatment of the problems and goes on to practical examples of the application. For flaws that have a width of at least 0.3 mm, a thickness of the order 0.1 mm can be determined with sufficient accuracy in materials 40 mm thick.(P.Aa.)

  6. Advanced Neutron Radiographic Equipment within the US Army

    Science.gov (United States)

    2014-01-29

    The first of the two new neutron generators developed for ARDEC was built and delivered by Phoenix Nuclear Labs ( PNL ) located in Madison, WI...PRELIMINARY NEUTRON RADIOGRAPHS AND RESULTS During the hardware and software testing of the PNL neutron generator several test shots were

  7. Radiographic imaging of aids

    International Nuclear Information System (INIS)

    Mahmoud, Mohammed Bashir

    2002-07-01

    The acquired immunodeficiency syndrome (AIDS) has impacted the civilized world like no other disease. This research aimed to discuss some of the main aids-related complications and their detection by radiology tests, specifically central nervous system and musculoskeletal system disorders. The objectives are: to show specific characteristics of various diseases of HIV patient, to analyze the effect of pathology in patients by radiology, to enhance the knowledge of technologists in aids imaging and to improve communication skills between patient and radiology technologists

  8. Soliton Gases and Generalized Hydrodynamics

    Science.gov (United States)

    Doyon, Benjamin; Yoshimura, Takato; Caux, Jean-Sébastien

    2018-01-01

    We show that the equations of generalized hydrodynamics (GHD), a hydrodynamic theory for integrable quantum systems at the Euler scale, emerge in full generality in a family of classical gases, which generalize the gas of hard rods. In this family, the particles, upon colliding, jump forward or backward by a distance that depends on their velocities, reminiscent of classical soliton scattering. This provides a "molecular dynamics" for GHD: a numerical solver which is efficient, flexible, and which applies to the presence of external force fields. GHD also describes the hydrodynamics of classical soliton gases. We identify the GHD of any quantum model with that of the gas of its solitonlike wave packets, thus providing a remarkable quantum-classical equivalence. The theory is directly applicable, for instance, to integrable quantum chains and to the Lieb-Liniger model realized in cold-atom experiments.

  9. Anomalous hydrodynamics of Weyl materials

    Science.gov (United States)

    Monteiro, Gustavo; Abanov, Alexander

    Kinetic theory is a useful tool to study transport in Weyl materials when the band-touching points are hidden inside a Fermi surface. It accounts, for example, for the negative magnetoresistance caused by the chiral magnetic effect and quantum oscillations (SdH effect) in the magnetoresistance together within the same framework. As an alternative approach to kinetic theory we also consider the regime of strong interactions where hydrodynamics can be applicable. A variational principle of these hydrodynamic equations can be found in and provide a natural framework to study hydrodynamic surface modes which correspond to the strongly-interacting physics signature of Fermi arcs. G.M. acknowledges the financial support from FAPESP.

  10. Brownian dynamics with hydrodynamic interactions

    International Nuclear Information System (INIS)

    Ermak, D.L.; McCammon, J.A.

    1978-01-01

    A method for simulating the Brownian dynamics of N particles with the inclusion of hydrodynamic interactions is described. The particles may also be subject to the usual interparticle or external forces (e.g., electrostatic) which have been included in previous methods for simulating Brownian dynamics of particles in the absence of hydrodynamic interactions. The present method is derived from the Langevin equations for the N particle assembly, and the results are shown to be consistent with the corresponding Fokker--Planck results. Sample calculations on small systems illustrate the importance of including hydrodynamic interactions in Brownian dynamics simulations. The method should be useful for simulation studies of diffusion limited reactions, polymer dynamics, protein folding, particle coagulation, and other phenomena in solution

  11. Conventional frontal radiographs compared with frontal radiographs obtained from cone beam computed tomography.

    Science.gov (United States)

    Nur, Metin; Kayipmaz, Saadettin; Bayram, Mehmet; Celikoglu, Mevlut; Kilkis, Dogan; Sezgin, Omer Said

    2012-07-01

    To test the hypothesis that there is no difference between measurements performed on conventional frontal radiographs (FRs) and those performed on FRs obtained from cone beam computed tomography (CBCT) scans. This study consisted of conventional FRs and CBCT-constructed FRs obtained from 30 young adult patients. Twenty-three landmarks were identified on both types of cephalometric radiographs. Twenty-one widely used cephalometric variables (14 linear distances, 4 angles, and 3 ratios) were calculated. Paired t-tests were performed to compare the means of corresponding measurements on two cephalometric radiographs of the same patient. Reproducibility of measurements ranged from 0.85 to 0.99 for CBCT-constructed FRs, and from 0.78 to 0.96 for conventional FRs. A statistically significant difference was observed between conventional FRs and CBCT-constructed FRs for all linear measurements (eurR-eurL, loR-loL, moR-moL, zygR-zygL, lapR-lapL, mxR-mxL, maR-maL, umR-umL, lmR-lmL, agR-agL, me-ans) (P .05). However, no statistically significant differences were noted between conventional FRs and CBCT-constructed FRs for ratios and angular measurements (P > .05). The hypothesis was rejected. A difference has been noted between measurements performed on conventional FRs and those performed on CBCT-constructed FRs, particularly in terms of linear measurements.

  12. Abnormal pressures as hydrodynamic phenomena

    Science.gov (United States)

    Neuzil, C.E.

    1995-01-01

    So-called abnormal pressures, subsurface fluid pressures significantly higher or lower than hydrostatic, have excited speculation about their origin since subsurface exploration first encountered them. Two distinct conceptual models for abnormal pressures have gained currency among earth scientists. The static model sees abnormal pressures generally as relict features preserved by a virtual absence of fluid flow over geologic time. The hydrodynamic model instead envisions abnormal pressures as phenomena in which flow usually plays an important role. This paper develops the theoretical framework for abnormal pressures as hydrodynamic phenomena, shows that it explains the manifold occurrences of abnormal pressures, and examines the implications of this approach. -from Author

  13. Anisotropic hydrodynamics: Motivation and methodology

    Energy Technology Data Exchange (ETDEWEB)

    Strickland, Michael

    2014-06-15

    In this proceedings contribution I review recent progress in our understanding of the bulk dynamics of relativistic systems that possess potentially large local rest frame momentum-space anisotropies. In order to deal with these momentum-space anisotropies, a reorganization of relativistic viscous hydrodynamics can be made around an anisotropic background, and the resulting dynamical framework has been dubbed “anisotropic hydrodynamics”. I also discuss expectations for the degree of momentum-space anisotropy of the quark–gluon plasma generated in relativistic heavy ion collisions at RHIC and LHC from second-order viscous hydrodynamics, strong-coupling approaches, and weak-coupling approaches.

  14. Hydrodynamics of oceans and atmospheres

    CERN Document Server

    Eckart, Carl

    1960-01-01

    Hydrodynamics of Oceans and Atmospheres is a systematic account of the hydrodynamics of oceans and atmospheres. Topics covered range from the thermodynamic functions of an ideal gas and the thermodynamic coefficients for water to steady motions, the isothermal atmosphere, the thermocline, and the thermosphere. Perturbation equations, field equations, residual equations, and a general theory of rays are also presented. This book is comprised of 17 chapters and begins with an introduction to the basic equations and their solutions, with the aim of illustrating the laws of dynamics. The nonlinear

  15. Hydrodynamic constants from cosmic censorship

    International Nuclear Information System (INIS)

    Nakamura, Shin

    2008-01-01

    We study a gravity dual of Bjorken flow of N=4 SYM-theory plasma. We point out that the cosmic censorship hypothesis may explain why the regularity of the dual geometry constrains the hydrodynamic constants. We also investigate the apparent horizon of the dual geometry. We find that the dual geometry constructed on Fefferman-Graham (FG) coordinates is not appropriate for examination of the apparent horizon since the coordinates do not cover the trapped region. However, the preliminary analysis on FG coordinates suggests that the location of the apparent horizon is very sensitive to the hydrodynamic parameters. (author)

  16. Hydrodynamic simulation of elliptic flow

    CERN Document Server

    Kolb, P F; Ruuskanen, P V; Heinz, Ulrich W

    1999-01-01

    We use a hydrodynamic model to study the space-time evolution transverse to the beam direction in ultrarelativistic heavy-ion collisions with nonzero impact parameters. We focus on the influence of early pressure on the development of radial and elliptic flow. We show that at high energies elliptic flow is generated only during the initial stages of the expansion while radial flow continues to grow until freeze-out. Quantitative comparisons with SPS data from semiperipheral Pb+Pb collisions suggest the applicability of hydrodynamical concepts already $\\approx$ 1 fm/c after impact.

  17. Importance of radiographic monitoring of endoscopic sphincterotomy

    International Nuclear Information System (INIS)

    Greenberg, H.M.; Goldberg, H.I.; Shapiro, H.A.

    1981-01-01

    The radiographic features of endoscopic sphincterotomies performed in 44 patients were evaluated. Radiographic landmarks aided in proper sphincterotome placement and also disclosed conditions and anatomic variations that made catheter placement difficult. Fluoroscopic and radiographic monitoring not only assisted the performance of endoscopic sphincterotomy, but also confirmed successful results and revealed reasons for failure. Radiographic changes in the biliary tract after sphincterotomy, as well as potential complications of sphincterotomy, are discussed and illustrated

  18. Sensitometric properties and image quality of radiographic film and paper

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1985-09-01

    When using X-ray film or radiographic paper for industrial applications one is interested in knowing not only their sensitometric properties (such as speed and contrast) but also the image quality obtainable with a particular brand of film or paper. Although standard methods for testing both properties separately are available it is desirable that the method permits the assessment of all the relevant properties together. The sensitometric properties are usually determined at constant kilovoltage and filtration at the X-ray tube, whereas radiographic image thicknesses. The use of the constant exposure technique could be used to compare both the sensitometric properties as well as the image quality for different radiographic materials. It consist of exposing different film or paper brands at a chosen, constant mAmin exposure when testing radiographic image quality for different thicknesses of a given material. From the results obtained with the constant exposure technique conclusions are drawn about its applicability as a standard method for assessing radiographic film and paper. (author)

  19. Hydrodynamic bearing lubricated with magnetic fluids

    International Nuclear Information System (INIS)

    Urreta, H; Leicht, Z; Sanchez, A; Agirre, A; Kuzhir, P; Magnac, G

    2009-01-01

    This paper summarizes the work carried out in the development of hydrodynamic lubricated journal bearings with magnetic fluids. Two different fluids have been analyzed, one ferrofluid from FERROTEC APG s10n and one magnetorheological fluid from LORD Corp., MRF122-2ED. Theoretical analysis has been carried out with numerical solutions of Reynolds equation, based on apparent viscosity modulation for ferrofluid and Bingham model for MR fluid. To validate this model, one test bench has been designed, manufactured and set up, where preliminary results shown in this paper demonstrate that magnetic fluids can be used to develop active journal bearings.

  20. A retrospective study of the performance of radiographers in interpreting screening mammograms

    International Nuclear Information System (INIS)

    Moran, S.; Warren-Forward, H.

    2011-01-01

    Purpose: This paper provides data on the continued success of radiographers in reviewing mammograms with similar accuracy to screen readers. Method: The participants consisted of 7 radiographers and 2 current official screen readers. Two hundred and fifty sets of mammograms from 2003 were used in this study. Each participant reviewed each set of mammograms as a Rescreen or Recall. Patient outcomes were assessed by following up the results of any histology or pathology tests in 2003 or the 2005/2006 screening results. Results: The screen reader's sensitivities ranged from 79% to 93% and the specificities ranged from 82% to 84%. The radiographer values ranged from 57% to 97% and 63% to 80% respectively. Conclusion: The sensitivity and specificity values attained by some radiographers were equivalent to those of both the screen readers. Accuracy rates of the radiographers suggest that screen reading by selected and appropriately trained radiographers should be achievable in Australia.

  1. 21 CFR 892.1840 - Radiographic film.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic film. 892.1840 Section 892.1840 Food... DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1840 Radiographic film. (a) Identification. Radiographic film is a device that consists of a thin sheet of radiotransparent material coated on one or both...

  2. Predictive value of specific radiographic findings of disability in patients with rheumatoid arthritis

    International Nuclear Information System (INIS)

    Kaye, J.J.; Nance, E.P. Jr.; Callahan, L.F.; Pincus, T.

    1986-01-01

    This study was carried out to determine whether and to what extend radiographic erosion, joint space narrowing, and malalignment are predictive of clinical disability in patients with rheumatoid arthristis (RA). Radiographs of the hands and wrists of 224 patients with RA were scored for these radiographic parameters. To determine which of these findings best explained variation in clinical measures of disability, a series of regression analyses was performed. Malalignment scores were the best predictor of joint deformity and limitation of motion. Erosion scores were most predictive of variation in functional tests. The author concludes that specific radiographic findings of malalignment and erosion are significantly predictive of disability in patients with RA

  3. Radiographic examination takes on an automated image

    International Nuclear Information System (INIS)

    Aman, J.

    1988-01-01

    Automation can be effectively applied to nondestructive testing (NDT). Until recently, film radiography used in NDT was largely a manual process, involving the shooting of a series of x-rays, manually positioned and manually processed. In other words, much radiographic work is being done the way it was over 50 years ago. Significant advances in automation have changed the face of manufacturing, and industry has shared in the benefits brought by such progress. The handling of parts, which was once responsible for a large measure of labor costs, is now assigned to robotic equipment. In nondestructive testing processes, some progress has been achieved in automation - for example, in real-time imaging systems. However, only recently have truly automated NDT begun to emerge. There are two major reasons to introduce automation into NDT - reliability and productivity. Any process or technique that can improve the reliability of parts testing could easily justify the capital investments required

  4. Hydrodynamic Test Facilities at ARL/PSU.

    Science.gov (United States)

    1982-02-12

    Dynamometers, 5-Hole Pitot Probes, Lasers, Pressure Sensors, Hydrophones, Planar Motion Mechanism, Force Balances TYPE AND LOCATION OF TORQUE & THRUST...David W. Taylor Naval Ship R&D Center Atmn: J. Henry David W. Taylor Naval Ship R&D Center Code 2741 Attn: W. K. Blake (Copy No. 28) Code 1905 (Copy No

  5. Retention of anatomy knowledge by student radiographers

    International Nuclear Information System (INIS)

    Hall, A. Susanne; Durward, Brian R.

    2009-01-01

    Introduction: Anatomy has long been regarded as an integral part of the core curriculum. However, anecdotal evidence suggests that long-term retention of anatomy knowledge may be deficient. This study aims to evidence whether student radiographers demonstrate the same level of knowledge of anatomy after a period of time has elapsed and to correlate to approaches to learning and studying. Methodology: A repeated measures design was utilised to measure retention of anatomy knowledge for both MCQs and short-response answers to a Practical Radiographic Anatomy Examination; alpha value p < 0.05. Fifty-one students from levels 2 and 3 were retested after a time lapse of 10 and 22 months respectively. The students were not aware that their knowledge was being retested. Approaches to learning and studying were measured using the ASSIST inventory. Results: Statistical analysis found no difference in performance on MCQ assessment, in either the combined sample or levels 2 and 3 separately, from baseline to retention occasions; average retention rate being 99%. However, a statistical difference in performance on PRAE assessment was found, with level 2 experiencing a larger reduction in scores; retention rate of 67% compared to level 3 at 77%. The students perceived themselves to be principally strategic in their approach to learning and studying but no strong relationships were found when correlated to test scores. Conclusion: The student radiographers in this study demonstrated varied anatomy retention rates dependent on assessment method employed and time interval that had elapsed. It is recommended that diverse teaching and assessment strategies are adopted to encourage a deeper approach to learning and studying.

  6. Anomalous hydrodynamics in two dimensions

    Indian Academy of Sciences (India)

    Abstract. A new approach is presented to discuss two-dimensional hydrodynamics with gauge and gravitational anomalies. Exact constitutive relations for the stress tensor and charge current are obtained. Also, a connection between response parameters and anomaly coefficients is discussed. These are new results which, ...

  7. Topics in fluctuating nonlinear hydrodynamics

    International Nuclear Information System (INIS)

    Milner, S.T.

    1986-01-01

    Models of fluctuating nonlinear hydrodynamics have enjoyed much success in explaining the effect of long-wavelength fluctuations in diverse hydrodynamic systems. This thesis explores two such problems; in both, the body of hydrodynamic assumptions powerfully constrains the predictions of a well-posed theory. The effects of layer fluctuations in smectic-A liquid crystals are first examined. The static theory (introduced by Grinstein and Pelcovits) is reviewed. Ward identities, resulting from the arbitrariness of the layering direction, are derived and exploited. The static results motivate an examination of dynamic fluctuation effects. A new sound-damping experiment is proposed that would probe singular dependence of viscosities on applied stress. A theory of Procaccia and Gitterman that reaction rates of chemically reacting binary mixtures are drastically reduced near their thermodynamic critical points is analyzed. Hydrodynamic arguments and Van Hove theory are applied, concluding that the PG idea is drastically slowed, and spatially varying composition fluctuations are at best slowed down over a narrow range of wavenumbers

  8. Radiation hydrodynamics in the laboratory

    International Nuclear Information System (INIS)

    1985-12-01

    This report contains a collection of five preprints devoted to the subject of laser induced phenomena of radiation hydrodynamics. These preprints cover approximately the contents of the presentations made by the MPQ experimental laser-plasma group at the 17th European Conference on Laser Interaction with Matter (ECLIM), Rome, November 18-22, 1985. (orig.)

  9. Numerical Hydrodynamics in General Relativity

    Directory of Open Access Journals (Sweden)

    Font José A.

    2003-01-01

    Full Text Available The current status of numerical solutions for the equations of ideal general relativistic hydrodynamics is reviewed. With respect to an earlier version of the article, the present update provides additional information on numerical schemes, and extends the discussion of astrophysical simulations in general relativistic hydrodynamics. Different formulations of the equations are presented, with special mention of conservative and hyperbolic formulations well-adapted to advanced numerical methods. A large sample of available numerical schemes is discussed, paying particular attention to solution procedures based on schemes exploiting the characteristic structure of the equations through linearized Riemann solvers. A comprehensive summary of astrophysical simulations in strong gravitational fields is presented. These include gravitational collapse, accretion onto black holes, and hydrodynamical evolutions of neutron stars. The material contained in these sections highlights the numerical challenges of various representative simulations. It also follows, to some extent, the chronological development of the field, concerning advances on the formulation of the gravitational field and hydrodynamic equations and the numerical methodology designed to solve them.

  10. Hydrodynamics of a quark droplet

    DEFF Research Database (Denmark)

    Bjerrum-Bohr, Johan J.; Mishustin, Igor N.; Døssing, Thomas

    2012-01-01

    We present a simple model of a multi-quark droplet evolution based on the hydrodynamical description. This model includes collective expansion of the droplet, effects of the vacuum pressure and surface tension. The hadron emission from the droplet is described following Weisskopf's statistical...

  11. Hydrodynamic instabilities in inertial fusion

    International Nuclear Information System (INIS)

    Hoffman, N.M.

    1994-01-01

    This report discusses topics on hydrodynamics instabilities in inertial confinement: linear analysis of Rayleigh-Taylor instability; ablation-surface instability; bubble rise in late-stage Rayleigh-Taylor instability; and saturation and multimode interactions in intermediate-stage Rayleigh-Taylor instability

  12. Radiographic evaluation of maxillofacial fractures

    International Nuclear Information System (INIS)

    Litwan, M.; Fliegel, C.

    1986-01-01

    The course and configuration of typical maxillofacial fractures (type Le Fort I-III) and lateral maxillary fractures including the zygomatic arch were reconstructed in detail by application of barium paste on a bony skull and radiogrpahs in standard projections were performed and evaluated. It was obvious from the resulting radiographs that for most maxillofacial fractures a half axial or Water's view was most helpful. Lateral views only give additional information when there is a considerable degree of dislocation of fragments. Comparison with a prediatric skull of 8 years of age demonstrated that fractures of the zygomatic arch in this age group cannot be demonstrated by the typical submento-vertical view, but are shown on a Towne projection. The radiographic appearance of important maxillofacial fractures is demonstrated. The necessity of further studies in cases where reconstructive surgery appears necessary is discussed and CT rather then conventional tomography is advocated. (orig.) [de

  13. Comparisons of radiographic and electrocardiographic abnormalities in canine heartworm disease

    International Nuclear Information System (INIS)

    Calvert, C.A.; Losonsky, J.M.; Brown, J.; Lewis, R.E.

    1986-01-01

    Thoracic radiographs and electrocardiograms from 137 dogs with heartworm infection were independently evaluated and comparisons were made of (1) the presence or absence of right ventricular enlargement as assessed by these two diagnostic tests and (2) the presence or absence of right-sided congestive heart failure relative to the degree of right ventricular enlargement and ECG criteria of RVH. Radiographic evidence of severe, but not moderate, right ventricular enlargement was associated with right-sided congestive heart failure. Similarly the presence of three or more, but not fewer than three, ECG criteria of RVH were associated with right-sided congestive heart failure. If either the thoracic radiographs or the ECG indicated that severe right ventricular enlargement was absent, right-sided congestive heart failure was seldom present. The most accurate correlation of the radiographic evaluation of severe right ventricular enlargement was afforded by the presence of three or more ECG criteria of RVH. ECG criteria of RVH such as R/S v4 , + T v10 MEA x , and S 11 are highly specific tests; while S V2 is a highly sensitive but not highly specific test. The ECG is a good confirmation test of the presence of severe right ventricular enlargement and is a good exclusion test for the absence of right-sided congestive heart failure. (author)

  14. Pulmonary edema: radiographic differential diagnosis

    International Nuclear Information System (INIS)

    Yoo, Dong Soo; Choi, Young Hi; Kim, Seung Cheol; An, Ji Hyun; Lee, Jee Young; Park, Hee Hong

    1997-01-01

    To evaluate the feasibility of using chest radiography to differentiate between three different etiologies of pulmonary edema. Plain chest radiographs of 77 patients, who were clinically confirmed as having pulmonary edema, were retrospectively reviewed. The patients were classified into three groups : group 1 (cardiogenic edema : n = 35), group 2 (renal pulmonary edema : n = 16) and group 3 (permeability edema : n = 26). We analyzed the radiologic findings of air bronchogram, heart size, peribronchial cuffing, septal line, pleural effusion, vascular pedicle width, pulmonary blood flow distribution and distribution of pulmonary edema. In a search for radiologic findings which would help in the differentiation of these three etiologies, each finding was assessed. Cardiogenic and renal pulmonary edema showed overlapping radiologic findings, except for pulmonary blood flow distribution. In cardiogenic pulmonary edema (n=35), cardiomegaly (n=29), peribronchial cuffing (n=29), inverted pulmonary blood flow distribution (n=21) and basal distribution of edema (n=20) were common. In renal pulmonary edema (n=16), cardiomegaly (n=15), balanced blood flow distribution (n=12), and central (n=9) or basal distribution of edema (n=7) were common. Permeability edema (n=26) showed different findings. Air bronchogram (n=25), normal blood flow distribution (n=14) and peripheral distribution of edema (n=21) were frequent findings, while cardiomegaly (n=7), peribronchial cuffing (n=7) and septal line (n=5) were observed in only a few cases. On plain chest radiograph, permeability edema can be differentiated from cardiogenic or renal pulmonary edema. The radiographic findings which most reliably differentiated these two etiologies were air bronchogram, distribution of pulmonary edema, peribronchial cuffing and heart size. Only blood flow distribution was useful for radiographic differentiation of cardiogenic and renal edema

  15. Occupational health and the radiographer

    International Nuclear Information System (INIS)

    Stronach, T.

    1990-01-01

    This paper identifies some of the occupational health hazards faced by radiographers in the hospital environment. There has been very little work done in this area in the past, and as the subject is so large this paper can do little other than raise some of the issues . The hazards addressed include: radiation, ergonomics, chemical, environmental, biological, occupational injury and accident, stress. 14 refs., 2 figs

  16. Disinfection efficiency test (hypochlorite efficiency and hydrodynamic behaviour of the disinfection unit) in a large wastewater plant; Verifica del comportamento funzionale ed idrodinamico del processo di disinfezione con ipoclorito in un grande impianto di depurazione

    Energy Technology Data Exchange (ETDEWEB)

    Azzellino, A.; Volpe, G.; Vismara, R. [D.I.I.A.R. Sez. Ambientale, Politecnico di Milano, Milan (Italy); Bertoni, G. [Varese (Italy); Pezzana, A. [ARISTEA Legnano Srl, Sez. di Igiene Ambientale, Legnano (Italy)

    2000-12-01

    The latest Italian Water Act imposes for every wastewater treatment plant a disinfection facility. Testing the disinfection efficiency is even more important when considering the potential reuse of wastewater in agriculture. The new Water Act defines emission limits for surface water either in terms of microbiological indicators either in terms of chlorine residual levels. Particularly the actual law introduces a new bacteriological indicator (Escherichia coli) instead of the ones adopted by the previous legislation (mostly faecal coliform) but it does not indicate a standard method for its analytical determination. The presented paper concerns the testing of the hydrodynamic behaviour and the hypochlorite efficiency of a disinfection facility, located in S. Rocco Monza wastewater treatment plant. Tracer tests and different hypochlorite doses were applied in order to determine the disinfection efficiency of the contact reactor. As far as microbiological standards were concerned, it was chosen to use both the indicators E. coli and faecal coliforms in order to respect the actual legislation and the need of continuity with the past. The results did not show any difference in the sensitivity of the two microbiological indicators. [Italian] L'entrata in vigore del Decreto Legislativo 152/99 ha imposto che tutti gli impianti di depurazione delle acque reflue urbane, debbano obbligaoriamente dotarsi di un trattamento di disinfezione. La verifica dei processi di disinfezione diventa tanto piu' importante nel caso in cui si esamini la possibilita' di un potenziale riutilizzo delle acque reflue in agricoltura. Il recente decreto fissa nuovi valori limite d'emissione in acque superficiali sia in termini di organismi indice che di cloro libero residuo, introducendo alcuni elementi di novita'. In particolare, e' stato introdotto un nuovo organismo indice: l'Escherichia coli, in sostituzione di quelli precedentemente utilizzati (coliformi

  17. Automating the radiographic NDT process

    International Nuclear Information System (INIS)

    Aman, J.K.

    1986-01-01

    Automation, the removal of the human element in inspection, has not been generally applied to film radiographic NDT. The justication for automating is not only productivity but also reliability of results. Film remains in the automated system of the future because of its extremely high image content, approximately 8 x 10 9 bits per 14 x 17. The equivalent to 2200 computer floppy discs. Parts handling systems and robotics applied for manufacturing and some NDT modalities, should now be applied to film radiographic NDT systems. Automatic film handling can be achieved with the daylight NDT film handling system. Automatic film processing is becoming the standard in industry and can be coupled to the daylight system. Robots offer the opportunity to automate fully the exposure step. Finally, computer aided interpretation appears on the horizon. A unit which laser scans a 14 x 17 (inch) film in 6 - 8 seconds can digitize film information for further manipulation and possible automatic interrogations (computer aided interpretation). The system called FDRS (for Film Digital Radiography System) is moving toward 50 micron (*approx* 16 lines/mm) resolution. This is believed to meet the need of the majority of image content needs. We expect the automated system to appear first in parts (modules) as certain operations are automated. The future will see it all come together in an automated film radiographic NDT system (author) [pt

  18. A Radiographic Study of Odontoma

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Ho; Choi, Karp Shik [Dept. of Dental Radiology, College of Dentistry, Kyungpook National University, Daegu (Korea, Republic of)

    1998-02-15

    The purpose of this study was to obtain information on the clinical and radiographic features of the odontomas in the jaws. For this study, the authors examined and analyzed the clinical records and radiographs of 119 patients who had lesion of odontoma diagnosed by clinical and radiographic examinations. The obtained results were as follows: 1. Odontoma occurred the most frequently in the 2nd decade (45.4%) and occurred more frequently in males (60.5%) than in females (39.5%). 2. The most common clinical symptom was the delayed eruption of the teeth (34.2%). 3. The type of lesions was mainly observed as compound odontoma (80.8%), and internal pattern of the complex odontoma was unevenly radiopaque (73.9%). 4. The compound odontoma frequently occurred in anterior portion of the maxilla (57.7%) and mandible (30.9%), and complex odontoma frequently occurred in anterior portion of maxilla (34.8%) and posterior portion of mandible (30.5%). 5. The effects on adjacent teeth were impaction of teeth (71.7%) and prolonged retention of deciduous teeth (31.7%). 6. The impaction of the teeth occurred in anterior portion of maxilla (44.2%) amd mandible (19.2%), but root resorption of the adjacent teeth were not seen. 7. The boundary to adjacent structure was well-defined , the lesions appear as radiopaque mass with radiolucent rim.

  19. Cervical spine motion: radiographic study

    International Nuclear Information System (INIS)

    Morgan, J.P.; Miyabayashi, T.; Choy, S.

    1986-01-01

    Knowledge of the acceptable range of motion of the cervical spine of the dog is used in the radiographic diagnosis of both developmental and degenerative diseases. A series of radiographs of mature Beagle dogs was used to identify motion within sagittal and transverse planes. Positioning of the dog's head and neck was standardized, using a restraining board, and mimicked those thought to be of value in diagnostic radiology. The range of motion was greatest between C2 and C5. Reports of severe disk degeneration in the cervical spine of the Beagle describe the most severely involved disks to be C4 through C7. Thus, a high range of motion between vertebral segments does not seem to be the cause for the severe degenerative disk disease. Dorsoventral slippage between vertebral segments was seen, but was not accurately measured. Wedging of disks was clearly identified. At the atlantoaxio-occipital region, there was a high degree of motion within the sagittal plane at the atlantoaxial and atlanto-occipital joints; the measurement can be a guideline in the radiographic diagnosis of instability due to developmental anomalies in this region. Lateral motion within the transverse plane was detected at the 2 joints; however, motion was minimal, and the measurements seemed to be less accurate because of rotation of the cervical spine. Height of the vertebral canal was consistently noted to be greater at the caudal orifice, giving some warning to the possibility of overdiagnosis in suspected instances of cervical spondylopathy

  20. [Transparency regime: semiotics of radiographical images in urological diagnostics].

    Science.gov (United States)

    Martin, M; Fangerau, H

    2012-10-01

    Shortly after Röntgen discovered x-rays urology became one of the main test fields for the application of this new technology. Initial scepticism among physicians, who were inclined to cling to traditional manual methods of diagnosing, was replaced by enthusiasm for radiographic technologies and the new method soon became the standard in, for example the diagnosis of concrements. Patients favoring radiographic procedures over the use of probes and a convincing documentation of stones in radiograms were factors that impacted the relatively rapid integration of radiology into urology. The radiographic representation of soft tissues and body cavities was more difficult and the development of contrast agents in particular posed a serious problem. Several patients died during this research. A new diagnostic dimension was revealed when radiography and cystography were combined to form the method of retrograde pyelography. However, the problem of how urologists could learn how to read the new images remained. In order to allow trainee physicians to practice interpreting radiograms atlases were produced which offered explanatory texts and drawings for radiographic images of the kidneys, the bladder etc. Thus, urologists developed a self-contained semiotics which facilitated the appropriation of a unique urological radiographical gaze.

  1. Final Report. Hydrodynamics by high-energy-density plasma flow and hydrodynamics and radiative hydrodynamics with astrophysical application

    International Nuclear Information System (INIS)

    R Paul Drake

    2004-01-01

    OAK-B135 This is the final report from the project Hydrodynamics by High-Energy-Density Plasma Flow and Hydrodynamics and Radiation Hydrodynamics with Astrophysical Applications. This project supported a group at the University of Michigan in the invention, design, performance, and analysis of experiments using high-energy-density research facilities. The experiments explored compressible nonlinear hydrodynamics, in particular at decelerating interfaces, and the radiation hydrodynamics of strong shock waves. It has application to supernovae, astrophysical jets, shock-cloud interactions, and radiative shock waves

  2. Application of artificial neural network in radiographic diagnosis

    International Nuclear Information System (INIS)

    Piraino, D.; Amartur, S.; Richmond, B.; Schils, J.; Belhobek, G.

    1990-01-01

    This paper reports on an artificial neural network trained to rate the likelihood of different bone neoplasms when given a standard description of a radiograph. A three-layer back propagation algorithm was trained with descriptions of examples of bone neoplasms obtained from standard radiographic textbooks. Fifteen bone neoplasms obtained from clinical material were used as unknowns to test the trained artificial neural network. The artificial neural network correctly rated the pathologic diagnosis as the most likely diagnosis in 10 of the 15 unknown cases

  3. The Society and College of Radiographers - 60 years on

    International Nuclear Information System (INIS)

    Kinloch, J.

    1980-01-01

    The year 1980 heralded the Diamond Jubilee of the Society and College of Radiographers. A personal review of the history of the Society and College and its aims over the past sixty years is given. The review commences with the formation of the Society in 1920 and follows its testing time throughout the twenties, the expansion of its activities in the period up to the Second World War, its wartime function, its postwar activities particularly in relation to radiographers' conditions of service and salaries and finally the events of the 60's to the present day. (U.K.)

  4. Quality of the radiographic image in paper radiography

    International Nuclear Information System (INIS)

    Domanus, J.C.; El Fouly, H.M.

    1981-09-01

    The quality of the radiographic image was investigated by the use of standard ISO wire Image Quality Indicators and ASTM Penetrameters. 10, 20, and 30 mm thick welds on alumunium and steel plates were radiographed using X-ray machines with voltages from 35 to 300 kV. Agfa-Gevaert Structurix IC paper with Structurix IC screens Type II as well as Kodak Industrex 600 and 620 and Rapid 700 paper with Fl and F2 screens were used throughout the investigation. The results reached for radiographic paper were compared with those for a fast X-ray film (Kodak Industrex D). The results of the investigation were presented at the International Conference Joining of Metals JOM-1 in Elsinore, Denmark (9-12.8.1981) and at the Second European Conference on Non-Destructive Testing in Vienna (14-16.9.1981). The texts of both papers are reproduced in this report. (author)

  5. Imaging of juvenile spondyloarthritis. Part I: Classifications and radiographs

    Directory of Open Access Journals (Sweden)

    Iwona Sudoł-Szopińska

    2017-09-01

    Full Text Available Juvenile spondyloarthropathies are manifested mainly by symptoms of peripheral arthritis and enthesitis. By contrast with adults, children rarely present with sacroiliitis and spondylitis. Imaging and laboratory tests allow early diagnosis and treatment. Conventional radiographs visualize late inflammatory lesions and post-inflammatory complications. Early diagnosis is possible with the use of ultrasonography and magnetic resonance imaging. The first part of the article presents classifications of juvenile spondyloarthropathies and discusses their radiographic presentation. Typical radiographic features of individual types of juvenile spondyloarthritis are listed (including ankylosing spondylitis, juvenile psoriatic arthritis, reactive arthritis and arthritis in the course of inflammatory bowel diseases. The second part will describe changes visible on ultrasonography and magnetic resonance imaging. In patients with juvenile spondyloarthropathies, these examinations are conducted to diagnose inflammatory lesions in peripheral joints, tendon sheaths, tendons and bursae. Moreover, magnetic resonance imaging also visualizes early inflammatory changes in the axial skeleton and subchondral bone marrow edema, which is considered an early sign of inflammation.

  6. Defects quantization in industrial radiographs by image processing

    International Nuclear Information System (INIS)

    Briand, F.Y.; Brillault, B.; Philipp, S.

    1988-01-01

    This paper refers to the industrial application of image processing using Non Destructive Testing by radiography. The various problems involved by the conception of a numerical tool are described. This tool intends to help radiograph experts to quantify defects and to follow up their evolution, using numerical techniques. The sequences of processings that achieve defect segmentation and quantization are detailed. They are based on the thorough knowledge of radiographs formation techniques. The process uses various methods of image analysis, including textural analysis and morphological mathematics. The interface between the final product and users will occur in an explicit language, using the terms of radiographic expertise without showing any processing details. The problem is thoroughly described: image formation, digitization, processings fitted to flaw morphology and finally product structure in progress. 12 refs [fr

  7. Radiographic evaluation of cases referred for surgical endodontics

    NARCIS (Netherlands)

    Doornbusch, H.; Broersma, L.; Boering, G.; Wesselink, P.R.

    Aim The aim of this study is to test the hypothesis that more patients with failed root-canal treatment or other endodontic problems are referred for periradicular surgery rather than nonsurgical re-treatment. Methodology Three sets of 100 periapical radiographs representing typical cases referred

  8. Image quality in digital radiographic systems

    Directory of Open Access Journals (Sweden)

    Almeida Solange Maria de

    2003-01-01

    Full Text Available The aim of the present study was to evaluate the image quality of four direct digital radiographic systems. Radiographs were made of the maxillary central incisor and mandibular left molar regions of a dry skull, and an aluminum step-wedge. The X-ray generator operated at 10 mA, 60 and 70 kVp, and images were acquired with 3, 5, 8, 12, 24 and 48 exposure pulses. Six well-trained observers classified the images by means of scores from 1 to 3. Collected data were submitted to nonparametric statistical analysis using Fisher's exact test. Statistical analysis showed significant differences (p<0.01 in image quality with the four systems. Based on the results, it was possible to conclude that: 1 all of the digital systems presented good performance in producing acceptable images for diagnosis, if the exposures of the step-wedge and the maxillary central incisor region were made at 5 pulses, as well as at 8 pulses for the mandibular left molar region, selecting 60 or 70kVp; 2 higher percentages of acceptable images were obtained with the administration of lower radiation doses in CCD-sensors (charge-coupled device; 3 the Storage Phosphor systems produced acceptable images at a large range of exposure settings, that included low, intermediate and high radiation doses.

  9. Radiographic appearances in Crohn's disease. I. Accuracy of radiographic methods

    Energy Technology Data Exchange (ETDEWEB)

    Hildell, J; Lindstroem, C; Wenckert, A [Departments of Diagnostic Radiology, Pathology and Surgery, Malmoe Allmaenna Sjukhus, Malmoe, Sweden

    1979-01-01

    Preoperative films of 176 patients operated upon for Crohn's disease were reviewed and compared with microscopic findings in the resected specimens in order to assess the accuracy of the radiographic techniques used. It was found that a diagnosis of the presence and the extent of the disease was often dependent on the demonstration of minor mucosal ulcers and less marked submucosal edema. These lesions were not adequately demonstrated by any of the techniques used for small bowel examination, but were consistently revealed by the double-contrast technique used for examination of the colon.

  10. Radiographers' performance in chest X-ray interpretation: the Nigerian experience

    Science.gov (United States)

    Egbe, N O; Akpan, B E

    2015-01-01

    Objective: To assess the performance of Nigerian radiographers in interpretation of plain chest radiographs and to assess whether age, years since qualification and sector of practice are associated with performance. Methods: A test set of 50 radiographs containing 23 cases with no pathology (normal) and 27 abnormal cases (cardiopulmonary conditions) independently confirmed by 3 radiologists were presented to 51 radiographers in a random order. Readers independently evaluated radiographs for absence or presence of disease and stated the location, radiographic features and diagnosis. Readers self-reported their age, years since qualification and sector of practice. Receiver operating characteristic was used to assess the performance. Mann–Whitney U test was used to assess whether age, years since qualification and sector of practice were associated with performance. Results: Mean location sensitivity was 88.9 [95% confidence interval (CI), 0.787–0.980]. Mean sensitivity and specificity were 76.9 (95% CI, 0.658–0.864) and 79.8 (95% CI, 0.658–0.864), respectively. Age was not associated with performance (p = 0.07). Number of years qualified as radiographer (p = 0.005) and private practice (p = 0.004) were positively associated with performance. Conclusion: Nigerian radiographers can correctly report chest radiographs to a reasonable standard, and performance is associated with number of years since qualification and the sector of practice. Advances in knowledge: There are less than 300 radiologists serving a Nigerian population of about 170 million; therefore, X-ray interpretation by radiographers deserves consideration. Nigerian radiographers have potential to interpret chest X-ray in the clinical setting, and this may significantly improve radiology service delivery in this region. PMID:25966290

  11. Analytic solutions of hydrodynamics equations

    International Nuclear Information System (INIS)

    Coggeshall, S.V.

    1991-01-01

    Many similarity solutions have been found for the equations of one-dimensional (1-D) hydrodynamics. These special combinations of variables allow the partial differential equations to be reduced to ordinary differential equations, which must then be solved to determine the physical solutions. Usually, these reduced ordinary differential equations are solved numerically. In some cases it is possible to solve these reduced equations analytically to obtain explicit solutions. In this work a collection of analytic solutions of the 1-D hydrodynamics equations is presented. These can be used for a variety of purposes, including (i) numerical benchmark problems, (ii) as a basis for analytic models, and (iii) to provide insight into more complicated solutions

  12. Hydrodynamic perception in true seals (Phocidae) and eared seals (Otariidae).

    Science.gov (United States)

    Hanke, Wolf; Wieskotten, Sven; Marshall, Christopher; Dehnhardt, Guido

    2013-06-01

    Pinnipeds, that is true seals (Phocidae), eared seals (Otariidae), and walruses (Odobenidae), possess highly developed vibrissal systems for mechanoreception. They can use their vibrissae to detect and discriminate objects by direct touch. At least in Phocidae and Otariidae, the vibrissae can also be used to detect and analyse water movements. Here, we review what is known about this ability, known as hydrodynamic perception, in pinnipeds. Hydrodynamic perception in pinnipeds developed convergently to the hydrodynamic perception with the lateral line system in fish and the sensory hairs in crustaceans. So far two species of pinnipeds, the harbour seal (Phoca vitulina) representing the Phocidae and the California sea lion (Zalophus californianus) representing the Otariidae, have been studied for their ability to detect local water movements (dipole stimuli) and to follow hydrodynamic trails, that is the water movements left behind by objects that have passed by at an earlier point in time. Both species are highly sensitive to dipole stimuli and can follow hydrodynamic trails accurately. In the individuals tested, California sea lions were clearly more sensitive to dipole stimuli than harbour seals, and harbour seals showed a superior trail following ability as compared to California sea lions. Harbour seals have also been shown to derive additional information from hydrodynamic trails, such as motion direction, size and shape of the object that caused the trail (California sea lions have not yet been tested). The peculiar undulated shape of the harbour seals' vibrissae appears to play a crucial role in trail following, as it suppresses self-generated noise while the animal is swimming.

  13. Laser driven hydrodynamic instability experiments

    International Nuclear Information System (INIS)

    Remington, B.A.; Weber, S.V.; Haan, S.W.; Kilkenny, J.D.; Glendinning, S.G.; Wallace, R.J.; Goldstein, W.H.; Wilson, B.G.; Nash, J.K.

    1993-01-01

    An extensive series of experiments has been conducted on the Nova laser to measure hydrodynamic instabilities in planar foils accelerated by x-ray ablation. Single mode experiments allow a measurement of the fundamental growth rates from the linear well into the nonlinear regime. Two-mode foils allow a first direct observation of mode coupling. Surface-finish experiments allow a measurement of the evolution of a broad spectrum of random initial modes

  14. Hydrodynamic simulations of expanding shells

    Czech Academy of Sciences Publication Activity Database

    Wünsch, Richard; Palouš, Jan; Ehlerová, Soňa

    2004-01-01

    Roč. 289, 3-4 (2004), s. 35-36 ISSN 0004-640X. [From observation to self-consistent modelling of the ISM in galaxies. Porto, 03.09.2002-05.09.2002] R&D Projects: GA AV ČR KSK1048102 Keywords : hydrodynamic simulations * ISM * star formation Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics Impact factor: 0.597, year: 2004

  15. Hydrodynamic Limit of Multiple SLE

    Science.gov (United States)

    Hotta, Ikkei; Katori, Makoto

    2018-04-01

    Recently del Monaco and Schleißinger addressed an interesting problem whether one can take the limit of multiple Schramm-Loewner evolution (SLE) as the number of slits N goes to infinity. When the N slits grow from points on the real line R in a simultaneous way and go to infinity within the upper half plane H, an ordinary differential equation describing time evolution of the conformal map g_t(z) was derived in the N → ∞ limit, which is coupled with a complex Burgers equation in the inviscid limit. It is well known that the complex Burgers equation governs the hydrodynamic limit of the Dyson model defined on R studied in random matrix theory, and when all particles start from the origin, the solution of this Burgers equation is given by the Stieltjes transformation of the measure which follows a time-dependent version of Wigner's semicircle law. In the present paper, first we study the hydrodynamic limit of the multiple SLE in the case that all slits start from the origin. We show that the time-dependent version of Wigner's semicircle law determines the time evolution of the SLE hull, K_t \\subset H\\cup R, in this hydrodynamic limit. Next we consider the situation such that a half number of the slits start from a>0 and another half of slits start from -a exact solutions, we will discuss the universal long-term behavior of the multiple SLE and its hull K_t in the hydrodynamic limit.

  16. Hydrodynamical model with massless constituents

    International Nuclear Information System (INIS)

    Chiu, C.B.; Wang, K.H.

    1974-01-01

    Within the constituent hydrodynamical model, it is shown that the total number of constituents is conserved, if these constituents are massless and satisfy the Fermi-Dirac distribution. A simple scheme for the transition from the constituent-phase to the hadron-phase is suggested, and the hadron inclusive momentum spectra are presented for this case. This phase transition scheme predicts the average transverse momentum of meson resonances which is compatible with the data. (U.S.)

  17. Fish robotics and hydrodynamics

    Science.gov (United States)

    Lauder, George

    2010-11-01

    Studying the fluid dynamics of locomotion in freely-swimming fishes is challenging due to difficulties in controlling fish behavior. To provide better control over fish-like propulsive systems we have constructed a variety of fish-like robotic test platforms that range from highly biomimetic models of fins, to simple physical models of body movements during aquatic locomotion. First, we have constructed a series of biorobotic models of fish pectoral fins with 5 fin rays that allow detailed study of fin motion, forces, and fluid dynamics associated with fin-based locomotion. We find that by tuning fin ray stiffness and the imposed motion program we can produce thrust both on the fin outstroke and instroke. Second, we are using a robotic flapping foil system to study the self-propulsion of flexible plastic foils of varying stiffness, length, and trailing edge shape as a means of investigating the fluid dynamic effect of simple changes in the properties of undulating bodies moving through water. We find unexpected non-linear stiffness-dependent effects of changing foil length on self-propelled speed, and as well as significant effects of trailing edge shape on foil swimming speed.

  18. Black Hole Scrambling from Hydrodynamics.

    Science.gov (United States)

    Grozdanov, Sašo; Schalm, Koenraad; Scopelliti, Vincenzo

    2018-06-08

    We argue that the gravitational shock wave computation used to extract the scrambling rate in strongly coupled quantum theories with a holographic dual is directly related to probing the system's hydrodynamic sound modes. The information recovered from the shock wave can be reconstructed in terms of purely diffusionlike, linearized gravitational waves at the horizon of a single-sided black hole with specific regularity-enforced imaginary values of frequency and momentum. In two-derivative bulk theories, this horizon "diffusion" can be related to late-time momentum diffusion via a simple relation, which ceases to hold in higher-derivative theories. We then show that the same values of imaginary frequency and momentum follow from a dispersion relation of a hydrodynamic sound mode. The frequency, momentum, and group velocity give the holographic Lyapunov exponent and the butterfly velocity. Moreover, at this special point along the sound dispersion relation curve, the residue of the retarded longitudinal stress-energy tensor two-point function vanishes. This establishes a direct link between a hydrodynamic sound mode at an analytically continued, imaginary momentum and the holographic butterfly effect. Furthermore, our results imply that infinitely strongly coupled, large-N_{c} holographic theories exhibit properties similar to classical dilute gases; there, late-time equilibration and early-time scrambling are also controlled by the same dynamics.

  19. Student radiographers' attitudes toward the older patient – An intervention study

    International Nuclear Information System (INIS)

    Booth, L.; Kada, S.

    2015-01-01

    Purpose: To design, implement and evaluate the effect of an educational intervention on Norwegian student (diagnostic) radiographers' attitudes towards older people. Design: This study is part of a wider longitudinal study that will evaluate student radiographer attitudes towards the older patient as they progress through their training. In this phase an educational intervention, aimed at improving student radiographer attitudes towards the older person, was designed and implemented. What is reported here are the findings of a pre-test, post-test design that used the Kogan's attitudes towards older people scale to determine whether this intervention had any effect of student radiographer attitudes towards older people. Results: Overall students reported significantly more positive attitudes towards older people after intervention (p = 0.01). However, analysis of responses to individual questions reveals that this difference was not significant in all cases. Conclusion: The results of the present study suggest that an educational intervention can have a significant impact on student radiographer's attitudes towards older people. Whether this positive attitude remains throughout training, forms part of the wider basis for this study. - Highlights: • We designed an education intervention to improve Norwegian student radiographer attitudes towards older people. • Pre-intervention we found that these student radiographers generally had positive attitudes towards older people. • Post intervention the student radiographer's attitudes towards older people were significantly improved

  20. Poor Utility of Gonadal Shielding for Pediatric Pelvic Radiographs.

    Science.gov (United States)

    Lee, Mark C; Lloyd, Jessica; Solomito, Matthew J

    2017-07-01

    Plain pelvic radiographs are commonly used for a variety of pediatric orthopedic disorders. Lead shielding is typically placed over the gonads to minimize radiation exposure to these sensitive tissues. However, misplaced shielding can sabotage efforts to protect patients from excessive radiation exposure either by not covering radiosensitive tissues or by obscuring anatomic areas of interest, prompting repeat radiographic examinations. The goal of this study was to determine the incidence of misplaced shielding for pelvic radiographs obtained for pediatric orthopedic evaluation. Children 8 to 16 years old who had an anteroposterior or frog lateral pelvic radiograph between 2008 and 2014 were included. A total of 3400 patients met the inclusion criteria, and 84 boys and 84 girls were randomly selected for review. For both boys and girls, the percentage of incorrectly positioned or missing shields was calculated. Chi-square testing was used to compare the frequency of missing or incorrectly placed shields between sexes and age groups. Pelvic shields were misplaced in 49% of anteroposterior and 63% of frog lateral radiographs. Shielding was misplaced more frequently for girls than for boys on frog lateral radiographs (76% vs 51%; P<.05). Pelvic bony landmarks were often obscured by pelvic shielding, with a frequency of 7% to 43%, depending on the specific landmark. The femoral head and acetabulum were obscured by shielding in up to 2% of all images. The findings suggest that accepted pelvic shielding protocols are ineffective. Consideration should be given to alternative protocols or abandonment of this practice. [Orthopedics. 2017; 40(4):e623-e627.]. Copyright 2017, SLACK Incorporated.

  1. Performance evaluation of real time radiographic systems

    International Nuclear Information System (INIS)

    Venkatraman, B.; Saravanan, S.; Jayakumar, T.; Kalyanasundaram, P.; Baldev Raj

    1996-01-01

    The Real Time Radiography (RTR) system can be studied completely by knowing the modulation transfer function (MTF) of the whole system. The MTF curve is a special form of contrast/detail-size diagram in which the image contrast is plotted against the spatial frequency of a test object measured in line-pairs per millimetre (lp/mm). MTF curves are widely used to measure the characteristics of optical equipment, particularly for assessing the contribution of individual items in a complex imaging transfer system. Codes of practice indicate that the image intensifier systems should be checked periodically to assess its performance through the use of MTF curves and step wedges for contrast ratio. Authors, instead, suggest the use of performance curves which are simple to obtain and can be easily interpreted by radiographers. (author)

  2. Total elbow arthroplasty: a radiographic outcome study

    Energy Technology Data Exchange (ETDEWEB)

    Bai, Xue Susan [University of Washington, Department of Radiology, Box 357115, Seattle, WA (United States); Petscavage-Thomas, Jonelle M. [Penn State Hershey Medical Center, Department of Radiology, Hershey, PA (United States); Ha, Alice S. [University of Washington, Department of Radiology, Box 354755, Seattle, WA (United States)

    2016-06-15

    Total elbow arthroplasty (TEA) is becoming a popular alternative to arthrodesis for patients with end-stage elbow arthrosis and comminuted distal humeral fractures. Prior outcome studies have primarily focused on surgical findings. Our purpose is to determine the radiographic outcome of TEA and to correlate with clinical symptoms such as pain. This is an IRB-approved retrospective review from 2005 to 2015 of all patients with semiconstrained TEA. All available elbow radiographs and clinical data were reviewed. Data analysis included descriptive statistics and Kaplan-Meier survival curves for radiographic and clinical survival. A total of 104 total elbow arthroplasties in 102 patients were reviewed; 75 % were in women and the mean patient age was 63.1 years. Mean radiographic follow-up was 826 days with average of four radiographs per patient. Seventy TEAs (67 %) developed radiographic complications, including heterotopic ossification (48 %), perihardware lucency (27 %), periprosthetic fracture (23 %), hardware subluxation/dislocation (7 %), polyethylene wear (3 %), and hardware fracture/dislodgement (3 %); 56 patients (55 %) developed symptoms of elbow pain or instability and 30 patients (30 %) underwent at least one reoperation. In patients with radiographic complications, 66 % developed elbow pain, compared to 19 % of patients with no radiologic complications (p = 0.001). Of the patients with radiographic complications, 39 % had at least one additional surgery compared to 0 % of patients without radiographic complications (p = 0.056). Radiographic complications are common in patients after total elbow arthroplasty. There is a strong positive association between post-operative radiographic findings and clinical outcome. Knowledge of common postoperative radiographic findings is important for the practicing radiologist. (orig.)

  3. A radiographic analysis of implant component misfit.

    LENUS (Irish Health Repository)

    Sharkey, Seamus

    2011-07-01

    Radiographs are commonly used to assess the fit of implant components, but there is no clear agreement on the amount of misfit that can be detected by this method. This study investigated the effect of gap size and the relative angle at which a radiograph was taken on the detection of component misfit. Different types of implant connections (internal or external) and radiographic modalities (film or digital) were assessed.

  4. Radiation protection - radiographer's role and responsibilities

    International Nuclear Information System (INIS)

    Popli, P.K.

    2002-01-01

    Ever since discovery of x-rays, radiographers has been the prime user of radiation. With the passage of time, the harmful effects of radiation were detected. Some of radiographers, radiologists and public were affected by radiation, but today with enough knowledge of radiation, the prime responsibility of radiation protection lies with the radiographers only. The radiologist and physicist are also associated with radiation protection to some extent

  5. The use and abuse of radiographic grids

    International Nuclear Information System (INIS)

    Brough, P.D.

    1981-01-01

    It is generally accepted that scattered radiation degrades the quality of the radiographic image. When this problem occurs, a radiographic grid may be applied which necessitates an increase in exposure. Investigations are reported in the following areas: reasons for the introduction of a radiographic grid; the ratio between kilovoltage and grid ratio; techniques resulting in higher contrast and resolution at low patient dose and the abuse of grids

  6. Radiographic features of periapical cysts and granulomas

    OpenAIRE

    Zain, R. B.; Roswati, N.; Ismail, K.

    1989-01-01

    Many studies have been reported on radiographic lesion sizes of periapical lesions. However no studies have been reported on prevalences of subjective radiographic features in these lesions except for the early assumption that a periapical cyst usually exhibit a radiopaque cortex. This study is conducted to evaluate the prevalences of several subjective radiographic features of periapical cysts and granulomas in the hope to identify features that maybe suggestive of either diagnosis. The resu...

  7. Automating the radiographic NDT process

    International Nuclear Information System (INIS)

    Aman, J.K.

    1988-01-01

    Automation, the removal of the human element in inspection has not been generally applied to film radiographic NDT. The justification for automation is not only productivity but also reliability of results. Film remains in the automated system of the future because of its extremely high image content, approximately 3x10 (to the power of nine) bits per 14x17. This is equivalent to 2200 computer floppy disks parts handling systems and robotics applied for manufacturing and some NDT modalities, should now be applied to film radiographic NDT systems. Automatic film handling can be achieved with the daylight NDT film handling system. Automatic film processing is becoming the standard in industry and can be coupled to the daylight system. Robots offer the opportunity to automate fully the exposure step. Finally, a computer aided interpretation appears on the horizon. A unit which laser scans a 14x27 (inch) film in 6-8 seconds can digitize film in information for further manipulation and possible automatic interrogations (computer aided interpretation). The system called FDRS (for film digital radiography system) is moving toward 50 micron (16 lines/mm) resolution. This is believed to meet the need of the majority of image content needs. (Author). 4 refs.; 21 figs

  8. Prognostic radiographic aspects of spondylolisthesis

    International Nuclear Information System (INIS)

    Saraste, H.; Brostroem, L.A.; Aparisi, T.

    1984-01-01

    A series of 202 patients (133 men, 69 women) with lumbar spondylolysis were examined radiographically on two occasions, first at the time of diagnosis and later at a follow-up, after an observation period of 20 years or more. The films frompatients in groups without and with moderate and severe olisthesis were evaluated with respect to variables describing lumbosacral lordosis, wedging of the spondylolytic vertebra, lengths of the transverse processes and iliolumbar ligaments, disk height, progression of slipping, and influence on measured olisthesis of lumbar spine flexion and extension at the radiographic examination. The evaluation was made with special attention to possible signs which could be predictive for the prognosis of vertebral slipping. Progression of slipping did not differ between patients diagnosed as adults or adolescents. Reduction of disk height was correlated to the degree of slipping present at the initial examination and to the progression of olisthesis. Flexion and extension of the lumbar spine did not modify the degree of olisthesis. Data concerning the lengths of the transverse processes and the iliolumbar ligaments, and lumbar lordosis, cannot be used for prognostic purposes. The lumbar index reflecting the degree of wedge deformity of the spondylolytic vertebra was shown to be the only variable of prognostic value for the development of vertebral slipping. (orig.)

  9. Prognostic radiographic aspects of spondylolisthesis

    Energy Technology Data Exchange (ETDEWEB)

    Saraste, H; Brostroem, L A; Aparisi, T

    1984-01-01

    A series of 202 patients (133 men, 69 women) with lumbar spondylolysis were examined radiographically on two occasions, first at the time of diagnosis and later at a follow-up, after an observation period of 20 years or more. The films from patients in groups without and with moderate and severe olisthesis were evaluated with respect to variables describing lumbosacral lordosis, wedging of the spondylolytic vertebra, lengths of the transverse processes and iliolumbar ligaments, disk height, progression of slipping, and influence on measured olisthesis of lumbar spine flexion and extension at the radiographic examination. The evaluation was made with special attention to possible signs which could be predictive for the prognosis of vertebral slipping. Progression of slipping did not differ between patients diagnosed as adults or adolescents. Reduction of disk height was correlated to the degree of slipping present at the initial examination and to the progression of olisthesis. Flexion and extension of the lumbar spine did not modify the degree of olisthesis. Data concerning the lengths of the transverse processes and the iliolumbar ligaments, and lumbar lordosis, cannot be used for prognostic purposes. The lumbar index reflecting the degree of wedge deformity of the spondylolytic vertebra was shown to be the only variable of prognostic value for the development of vertebral slipping.

  10. Computational simulation of radiographic film

    International Nuclear Information System (INIS)

    Goncalves, Elicardo A. de S.; Santos, Marcio H. dos; Anjos, Marcelino J.; Oliveira, Luis F. de

    2013-01-01

    The composition of a radiographic film gives its values of speed, spatial resolution and base density. The technical knowledge allows to predict how a film with a known composition works, and simulate how this film will work with changes in composition and exposure. In this paper, characterization of films composed by different emulsions was realized, in a way to know the characteristic curve, and to study how the format, organization and concentration of silver salt crystals set the radiographic film images.This work aims to increase an existing simulator, where parallel programming was used to simulate X-ray fluorescence processes. The setup of source and X-ray interactions with objects stills the same, and the detector constructed in this work was placed to form images. At first, considering the approach that the film is a square matrix where each element has a specific quantity of silver grains, that each grain fills a specific area, and that each interaction to radiation transforms a salt silver grain in to metallic silver grain (black grain), we have a blackening standard, and it should show how is the behavior of a optic density in a specific area of the film. Each matrix element has a degree of blackening, and it is proportional to the black grains area. (author)

  11. Stepped scanner radiographic imaging system

    International Nuclear Information System (INIS)

    Lapidus, S.N.

    1981-01-01

    The imaging system includes a radiographic camera, a bed for supporting a subject in view of the camera, and a display system. The camera provides X and Y coordinate signals of each radiographic event. The position of the bed relative to the camera is altered sequentially by drive means, between each of a sequence of images provided by the camera. The sequentially occurring images are presented on the display system, each image being positioned on the display in correspondence with the location of the bed relative to the camera. The coordinates of each image point presented on the display is equal to the sum of the respective X and Y coordinate signals from the camera with X and Y coordinate signals provided by a timer which controls the drive means and defines the location of the bed relative to the camera. The camera is electronically decoupled from the display by a gate during movement of the bed relative to the camera from one location to the next location to prevent any smearing effect within the composite image presented on the display. (author)

  12. Gastric tumors on chest radiographs

    International Nuclear Information System (INIS)

    Tamura, Shozo; Kawanami, Takashi; Russell, W.J.

    1978-04-01

    Gastric neoplasms of three patients protruded into their gas-containing fornices and were first visualized on plain chest radiographs. Endoscopy and/or surgery confirmed these to be a polyp, a leiomyoma, and an adenocarcinoma. The polyp, 1.3 cm in diameter, was the smallest of these three, but smaller lesions may be detectable under suitable conditions. Adequate technique and positioning, sufficiently large lesions in the upper portion of the stomach, a central beam tangential to the tumor, sufficient gas in the stomach, and careful scrutiny by the observer are required. Lesions may be more readily visualized during chest radiography when oral sodium bicarbonate is used to distend the stomach. In chest radiography, exposure limited to the lung fields has been advocated for economy and dose reduction. However, too small an exposure field may result in loss of information potentially beneficial to the patient. Using the smaller of two popular film sizes (35 x 43 cm and 35 x 35 cm), the saving in surface and bone marrow doses is negligible, and the saving in gonad dose may be nil over that when shielding is used. The interest of the observer may be absorbed by a concomitant cardiac or pulmonary lesion. Careful scrutiny of the entire radiograph is therefore essential. (author)

  13. Radiographic localization of unerupted mandibular anterior teeth.

    Science.gov (United States)

    Jacobs, S G

    2000-10-01

    The parallax method and the use of 2 radiographs taken at right angles to each other are the 2 methods generally used to accurately localize teeth. For the parallax method, the combination of a rotational panoramic radiograph with an occlusal radiograph is recommended. This combination involves a vertical x-ray tube shift. Three case reports are presented that illustrate: (1) how this combination can accurately localize unerupted mandibular anterior teeth, (2) how a deceptive appearance of the labiolingual position of the unerupted tooth can be produced in an occlusal radiograph, (3) how increasing the vertical angle of the tube for the occlusal radiograph makes the tube shift easier to discern, (4) why occlusal radiographs are preferable to periapical radiographs for tube shifts, and (5) how localization can also be carried out with 2 radiographs at right angles to each other, one of which is an occlusal radiograph taken with the x-ray tube directed along the long axis of the reference tooth.

  14. Radiographic examination for successful dental implant

    International Nuclear Information System (INIS)

    Lee, Sam Sun; Choi, Soon Chul

    2005-01-01

    Recently implant has become an important field in dental clinic. Radiographic examination of pre- and post-operation is essential for successful treatment. Clinicians should have knowledge about the purpose of the radiographic examination, suitable imaging modality for the cases, anatomic landmarks of tooth and jaw bone, advantage and limitation of panoramic radiographic examination for implant, principle and interpretation of cross-sectional imaging, bone mineral density, post-operative radiographic examination. This paper will be helpful to get above information for dentists who want to do dental implant successfully.

  15. Reference Neutron Radiographs of Nuclear Reactor Fuel

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    Reference neutron radiographs of nuclear reactor fuel were produced by the Euraton Neutron Radiography Working Group and published in 1984 by the Reidel Publishing Company. In this collection a classification is given of the various neutron radiographic findings, that can occur in different parts...... of pelletized, annular and vibro-conpacted nuclear fuel pins. Those parts of the pins are shown where changes of appearance differ from those for the parts as fabricated. Also radiographs of those as fabricated parts are included. The collection contains 158 neutron radiographs, reproduced on photographic paper...

  16. Assessing the Hydrogeomorphic Effects of Environmental Flows using Hydrodynamic Modeling.

    Science.gov (United States)

    Gregory, Angela; Morrison, Ryan R; Stone, Mark

    2018-04-13

    Water managers are increasingly using environmental flows (e-flows) as a tool to improve ecological conditions downstream from impoundments. Recent studies have called for e-flow approaches that explicitly consider impacts on hydrogeomorphic processes when developing management alternatives. Process-based approaches are particularly relevant in river systems that have been highly modified and where water supplies are over allocated. One-dimensional (1D) and two-dimensional (2D) hydrodynamic models can be used to resolve hydrogeomorphic processes at different spatial and temporal scales to support the development, testing, and refinement of e-flow hypotheses. Thus, the objective of this paper is to demonstrate the use of hydrodynamic models as a tool for assisting stakeholders in targeting and assessing environmental flows within a decision-making framework. We present a case study of e-flows on the Rio Chama in northern New Mexico, USA, where 1D and 2D hydrodynamic modeling was used within a collaborative process to implement an e-flow experiment. A specific goal of the e-flow process was to improve spawning habitat for brown trout by flushing fine sediments from gravel features. The results revealed that the 2D hydrodynamic model provided much greater insight with respect to hydrodynamic and sediment transport processes, which led to a reduction in the recommended e-flow discharge. The results suggest that 2D hydrodynamic models can be useful tools for improving process understanding, developing e-flow recommendations, and supporting adaptive management even when limited or no data are available for model calibration and validation.

  17. Solitonic Dispersive Hydrodynamics: Theory and Observation

    Science.gov (United States)

    Maiden, Michelle D.; Anderson, Dalton V.; Franco, Nevil A.; El, Gennady A.; Hoefer, Mark A.

    2018-04-01

    Ubiquitous nonlinear waves in dispersive media include localized solitons and extended hydrodynamic states such as dispersive shock waves. Despite their physical prominence and the development of thorough theoretical and experimental investigations of each separately, experiments and a unified theory of solitons and dispersive hydrodynamics are lacking. Here, a general soliton-mean field theory is introduced and used to describe the propagation of solitons in macroscopic hydrodynamic flows. Two universal adiabatic invariants of motion are identified that predict trapping or transmission of solitons by hydrodynamic states. The result of solitons incident upon smooth expansion waves or compressive, rapidly oscillating dispersive shock waves is the same, an effect termed hydrodynamic reciprocity. Experiments on viscous fluid conduits quantitatively confirm the soliton-mean field theory with broader implications for nonlinear optics, superfluids, geophysical fluids, and other dispersive hydrodynamic media.

  18. Chest radiographic findings of tsutsugamushi disease and murine typhus in Chunchon

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Heung Chul; Han, Tae Giun; Jang, Won Ho; Hwang, Woo Chul; Park, Man Soo; Lee, Myoung Gu; Kim, Yoon Won [School of Medicine, Hallym University, Chuncheon (Korea, Republic of); Park, Choong Ki [College of Medicine, Hanyang University, Guri (Korea, Republic of)

    1995-06-15

    To evaluate the chest radiographic findings of rickettsial disease including murine typhus and tsutsugamushi disease in Chunchon. Chest radiographic films of 81 cases diagnosed as rickettsial disease(55 cases of tsutsugamushi disease, 26 cases of murine typhus) by immunofluorescence test were retrospectively analyzed. Main serotypes of Rickettsia tsutsugamushi were Gilliam and Karp. Incidence rate of tsutsugamushi disease was 2.1 times greater than that of murine typhus. Chest radiographs were abnormal in 63.6% of tsutsugamushi disease, and in 30.8% of murine typhus. Radiographic findings were Kerly's B line, reticulonodular densities, hilar enlargement, pleural effusion, and splenomegaly in both entities, but pulmonary consolidation was only found in tsutsugamushi disease. The patients with the abnormal radiographic findings were statistically well correlated with cardiomegaly ({rho} < 0.01) and azygos engorgement ({rho} < 0.05), as compared to the patients with normal radiographic findings. Radiographic findings of both murine typhus and tsutsugamushi disease were interstitial pattern. But the chest radiographs in patients with tsutsugamushi disease showed more severe pattern with higher rate of abnormality.

  19. Significance of radiographic abnormalities in patients with tibial stress injuries: correlation with magnetic resonance imaging

    International Nuclear Information System (INIS)

    Kijowski, Richard; Choi, James; Smet, Arthur de; Mukharjee, Rajat

    2007-01-01

    The objective was to correlate radiographic findings with magnetic resonance imaging (MRI) findings in patients with suspected tibial stress injuries in order to determine the significance of radiographic signs of stress injury in these individuals. The study group consisted of 80 patients with suspected tibial stress injuries who underwent a radiographic and MR examination of the tibia. Nineteen patients had bilateral involvement. Thus, a total of 99 tibias were evaluated. All radiographs and MR examinations were retrospectively reviewed, 1 month apart, in consensus by two musculoskeletal radiologists. The radiographs were reviewed without knowledge of the site of the clinical symptoms. Fisher's exact tests were used to determine the association between a positive radiograph and the presence of various MRI signs of a high-grade stress injury. There was a strong association between the presence of periosteal reaction on radiographs at the site of the clinical symptoms and a Fredericson grade 4 stress injury on MRI. The presence of periosteal reaction on radiographs at the site of clinical symptoms is predictive of a high-grade stress injury by MRI criteria. (orig.)

  20. Chest radiographic findings of tsutsugamushi disease and murine typhus in Chunchon

    International Nuclear Information System (INIS)

    Kim, Heung Chul; Han, Tae Giun; Jang, Won Ho; Hwang, Woo Chul; Park, Man Soo; Lee, Myoung Gu; Kim, Yoon Won; Park, Choong Ki

    1995-01-01

    To evaluate the chest radiographic findings of rickettsial disease including murine typhus and tsutsugamushi disease in Chunchon. Chest radiographic films of 81 cases diagnosed as rickettsial disease(55 cases of tsutsugamushi disease, 26 cases of murine typhus) by immunofluorescence test were retrospectively analyzed. Main serotypes of Rickettsia tsutsugamushi were Gilliam and Karp. Incidence rate of tsutsugamushi disease was 2.1 times greater than that of murine typhus. Chest radiographs were abnormal in 63.6% of tsutsugamushi disease, and in 30.8% of murine typhus. Radiographic findings were Kerly's B line, reticulonodular densities, hilar enlargement, pleural effusion, and splenomegaly in both entities, but pulmonary consolidation was only found in tsutsugamushi disease. The patients with the abnormal radiographic findings were statistically well correlated with cardiomegaly (ρ < 0.01) and azygos engorgement (ρ < 0.05), as compared to the patients with normal radiographic findings. Radiographic findings of both murine typhus and tsutsugamushi disease were interstitial pattern. But the chest radiographs in patients with tsutsugamushi disease showed more severe pattern with higher rate of abnormality

  1. Chest radiographic findings of tsutsugamushi disease and murine typhus in Chunchon

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Heung Chul; Han, Tae Giun; Jang, Won Ho; Hwang, Woo Chul; Park, Man Soo; Lee, Myoung Gu; Kim, Yoon Won [School of Medicine, Hallym University, Chuncheon (Korea, Republic of); Park, Choong Ki [College of Medicine, Hanyang University, Guri (Korea, Republic of)

    1995-06-15

    To evaluate the chest radiographic findings of rickettsial disease including murine typhus and tsutsugamushi disease in Chunchon. Chest radiographic films of 81 cases diagnosed as rickettsial disease(55 cases of tsutsugamushi disease, 26 cases of murine typhus) by immunofluorescence test were retrospectively analyzed. Main serotypes of Rickettsia tsutsugamushi were Gilliam and Karp. Incidence rate of tsutsugamushi disease was 2.1 times greater than that of murine typhus. Chest radiographs were abnormal in 63.6% of tsutsugamushi disease, and in 30.8% of murine typhus. Radiographic findings were Kerly's B line, reticulonodular densities, hilar enlargement, pleural effusion, and splenomegaly in both entities, but pulmonary consolidation was only found in tsutsugamushi disease. The patients with the abnormal radiographic findings were statistically well correlated with cardiomegaly ({rho} < 0.01) and azygos engorgement ({rho} < 0.05), as compared to the patients with normal radiographic findings. Radiographic findings of both murine typhus and tsutsugamushi disease were interstitial pattern. But the chest radiographs in patients with tsutsugamushi disease showed more severe pattern with higher rate of abnormality.

  2. Prenatal radiographic diagnosis of alpha-fetoprotein positive malformations in early pregnancy

    International Nuclear Information System (INIS)

    Probst, F.P.; Sigurd, J.

    1980-01-01

    Early diagnosis of two malformed fetuses with positive alpha-fetoprotein test of the amniotic fluid with the aid of amniography is reported. Radiographic, diagnostic and prognostic aspects are discussed. (Auth.)

  3. Hydrodynamic interactions in active colloidal crystal microrheology

    OpenAIRE

    Weeber, R; Harting, JDR Jens

    2012-01-01

    In dense colloids it is commonly assumed that hydrodynamic interactions do not play a role. However, a found theoretical quantification is often missing. We present computer simulations that are motivated by experiments where a large colloidal particle is dragged through a colloidal crystal. To qualify the influence of long-ranged hydrodynamics, we model the setup by conventional Langevin dynamics simulations and by an improved scheme with limited hydrodynamic interactions. This scheme signif...

  4. Disruptive Innovation in Numerical Hydrodynamics

    Energy Technology Data Exchange (ETDEWEB)

    Waltz, Jacob I. [Los Alamos National Laboratory

    2012-09-06

    We propose the research and development of a high-fidelity hydrodynamic algorithm for tetrahedral meshes that will lead to a disruptive innovation in the numerical modeling of Laboratory problems. Our proposed innovation has the potential to reduce turnaround time by orders of magnitude relative to Advanced Simulation and Computing (ASC) codes; reduce simulation setup costs by millions of dollars per year; and effectively leverage Graphics Processing Unit (GPU) and future Exascale computing hardware. If successful, this work will lead to a dramatic leap forward in the Laboratory's quest for a predictive simulation capability.

  5. Laser driven hydrodynamic instability experiments

    International Nuclear Information System (INIS)

    Remington, B.A.; Weber, S.V.; Haan, S.W.; Kilkenny, J.D.; Glendinning, S.G.; Wallace, R.J.; Goldstein, W.H.; Wilson, B.G.; Nash, J.K.

    1992-01-01

    We have conducted an extensive series of experiments on the Nova laser to measure hydrodynamic instabilities in planar foils accelerated by x-ray ablation. Single mode experiments allow a measurement of the fundamental growth rates from the linear well into the nonlinear regime; multimode foils allow an assessment of the degree of mode coupling; and surface-finish experiments allow a measurement of the evolution of a broad spectrum of random initial modes. Experimental results and comparisons with theory and simulations are presented

  6. Hydrodynamics of post CHF region

    International Nuclear Information System (INIS)

    Ishii, M.; De Jarlais, G.

    1984-04-01

    Among various two-phase flow regimes, the inverted flow in the post-dryout region is relatively less well understood due to its special heat transfer conditions. The review of existing data indicates further research is needed in the areas of basic hydrodynamics related to liquid core disintegration mechanisms, slug and droplet formations, entrainment, and droplet size distributions. In view of this, the inverted flow is studied in detail both analytically and experimentally. Criteria for initial flow regimes in the post-dryout region are given. Preliminary models for subsequent flow regime transition criteria are derived together with correlations for a mean droplet diameter based on the adiabatic simulation data

  7. Problems in astrophysical radiation hydrodynamics

    International Nuclear Information System (INIS)

    Castor, J.I.

    1983-01-01

    The basic equations of radiation hydrodynamics are discussed in the regime that the radiation is dynamically as well as thermally important. Particular attention is paid to the question of what constitutes an acceptable approximate non-relativistic system of dynamical equations for matter and radiation in this regime. Further discussion is devoted to two classes of application of these ideas. The first class consists of problems dominated by line radiation, which is sensitive to the velocity field through the Doppler effect. The second class is of problems in which the advection of radiation by moving matter dominates radiation diffusion

  8. The influence of a continuing education program on the image interpretation accuracy of rural radiographers.

    Science.gov (United States)

    Smith, Tony N; Traise, Peter; Cook, Aiden

    2009-01-01

    In regional, rural and remote clinical practice, radiographers work closely with medical members of the acute care team in the interpretation of radiographic images, particularly when no radiologist is available. However, the misreading of radiographs by non-radiologist physicians has been shown to be the most common type of clinical error in the emergency department. Further, in Australia few rural radiographers are specifically trained to interpret and report on images. This study aimed to evaluate the accuracy of a group of rural radiographers in interpreting musculoskeletal plain radiographs, and to assess the effectiveness of continuing education (CE) in improving their accuracy within a short time frame. Following ethics approval, 16 rural radiographers were recruited to the study. At inception a purpose-designed 'test-object' of 25 cases compiled by a radiologist was used to assess image interpretation accuracy. The cases were categorised into three grades of complexity. The radiographers entered their answers on a structured radiographer opinion form (ROF) that had three levels of response - 'general opinion', 'observations' and 'open comment'. Subsequent to base-line testing, the radiographers participated in a CE program aimed at improving their image interpretation skills. After a 4 month period they were re-tested using the same methodology. The ROFs were scored by the radiologist and the pooled results analysed for statistically significant changes at all ROF levels and grades of complexity. While for the small number of less complex grade 1 cases there was no change in image interpretation accuracy, for the more numerous and more complex grade 2 and grade 3 cases there was a statistically significant improvement at the 'general opinion' and 'observation' levels (paired t-test, p radiologist. However, radiographers' ability to use radiological vocabulary needs improvement. The complementary role that exists between radiographers and other members of

  9. Stereoscopic radiographic images with gamma source encoding

    International Nuclear Information System (INIS)

    Strocovsky, S.G.; Otero, D

    2012-01-01

    Conventional radiography with X-ray tube has several drawbacks, as the compromise between the size of the focal spot and the fluence. The finite dimensions of the focal spot impose a limit to the spatial resolution. Gamma radiography uses gamma-ray sources which surpass in size, portability and simplicity to X-ray tubes. However, its low intrinsic fluence forces to use extended sources that also degrade the spatial resolution. In this work, we show the principles of a new radiographic technique that overcomes the limitations associated with the finite dimensions of X-ray sources, and that offers additional benefits to conventional techniques. The new technique called coding source imaging (CSI), is based on the use of extended sources, edge-encoding of radiation and differential detection. The mathematical principles and the method of images reconstruction with the new proposed technique are explained in the present work. Analytical calculations were made to determine the maximum spatial resolution and the variables on which it depends. The CSI technique was tested by means of Monte Carlo simulations with sets of spherical objects. We show that CSI has stereoscopic capabilities and it can resolve objects smaller than the source size. The CSI decoding algorithm reconstructs simultaneously four different projections from the same object, while conventional radiography produces only one projection per acquisition. Projections are located in separate image fields on the detector plane. Our results show it is possible to apply an extremely simple radiographic technique with extended sources, and get 3D information of the attenuation coefficient distribution for simple geometry objects in a single acquisition. The results are promising enough to evaluate the possibility of future research with more complex objects typical of medical diagnostic radiography and industrial gamma radiography (author)

  10. Radiographic Co-60 in component of heavy equipment casting

    International Nuclear Information System (INIS)

    Djoli Soembogo, Harun Al Rasyid R dan Namad Sianta

    2016-01-01

    The application of radiography using isotope Co-60 source has been used on component of heavy equipment such as component of heavy equipment casting. Components of heavy equipment casting made through metal casting of carbon steel. This study tried applying digital radiography are using isotope Co-60 sources and using scanning positive film media of Epson V700 for digitization results of conventional radiographic films. This radiography is using film AGFA D7 and Fuji 100 to obtain a contrast medium, medium sensitivity and image quality is good. The purpose radiographic Co-60 at a component of heavy equipment casting is detecting indications of the shape and type casting defects of component of heavy equipment casting thus fit for use. Radiographic test of Co-60 has been carried out on component of heavy equipment casting with single wall single image method and the results of radiographic films digitization using scanning positive film media of Epson V700 with observation parameters casting defects. Time exposure of Co-60 radiation was 10 and 15 minutes hours for metal castings of carbon steel for thickness 20.00-50.00 mm by using activity 30.05 Ci and the perpendicular distance to the source of the film is 820 mm. Scanner positive film results in the form of digital radiography which allow for the transfer of digital data or digital computerized data storage. Radiographic test results on component of heavy equipment casting with single wall single image method produce the parameter casting defect of component of heavy equipment casting in position of critical area is found shrinkage that should be repaired and in position of safety area is not found defect indication so casting defect of component of heavy equipment casting are not acceptable according to standards referenced. (author)

  11. Visual perception and radiographic interpretation

    International Nuclear Information System (INIS)

    Papageorges, M.

    1998-01-01

    Although interpretation errors are common in radiology, their causes are still debated. Perceptual mechanisms appear to be responsible for a large proportion of mistakes made by both neophytes and trained radiologists. Erroneous perception of familiar contours can be triggered by unrelated opacities. Conversely, visual information cannot induce a specific perception if the observer is not familiar with the concept represented or its radiographicappearance. Additionally, the area of acute vision is smaller than is commonly recognized. Other factors, such as the attitude, beliefs,.: preconceptions, and expectations of the viewer, can affect what he or she ''sees'' whenviewing any object, including a radiograph. Familiarity with perceptual mechanisms and the limitations of the visual system as well as multiple readings may be necessary to reduce interpretation errors

  12. Picture chamber for radiographic system

    International Nuclear Information System (INIS)

    1977-01-01

    The picture chamber for a radiographic system is characterised by a base, a first electrode carried in the base, an X-ray irradiation window provided with an outer plate and an inner plate and a conducting surface which serves as a second electrode, which has a plate gripping it at each adjacent edge and which has at the sides a space which is occupied by a filling material, maintained at a steady pressure, by means of the mounting against the base and wherein the inner plate lies against the first electrode and which is provided with a split, and with means for the separation of the split in the area of the inner plate so that a fluid may be retained in the split. (G.C.)

  13. Radiographic techniques for digital mammography

    International Nuclear Information System (INIS)

    Horita, Katsuhei

    2007-01-01

    Since the differences in X-ray absorption between various breast tissues are small, a dedicated X-ray system for examination of the breast and a high-contrast, high-resolution screen/film system (SFM) (light-receiving system) are employed for X-ray diagnosis. Currently, however, there is a strong trend toward digital imaging in the field of general radiography, and this trend is also reflected in the field of mammographic examination. In fact, approximately 70% of facilities purchasing new mammography systems are now selecting a digital mammography system (DRM). Given this situation, this report reviews the differences between SFM and DRM and discusses the radiographic techniques and quality assurance procedures for digital mammography. (author)

  14. Gout: radiographic findings mimicking infection

    International Nuclear Information System (INIS)

    Rousseau, I.; Raymond-Tremblay, D.; Cardinal, E.; Beauregard, C.G.; Braunstein, E.M.; Saint-Pierre, A.

    2001-01-01

    Objective: To describe radiographic features of gout that may mimic infection. Design and patients: We report five patients with acute bacterial gout who presented with clinical as well as radiological findings mimicking acute bacterial septic arthritis or osteomyelitis. Three patients had delay in the appropriate treatment with the final diagnosis being established after needle aspiration and identification of urate crystals under polarized light microscopy. Two patients underwent digit amputation for not responding to antibiotic treatment and had histological findings confirming the diagnosis of gout. Conclusion: It is important for the radiologist to be aware of the radiological manifestations of acute gout that can resemble infection in order to avoid inappropriate diagnosis and delay in adequate treatment. The definitive diagnosis should rely on needle aspiration and a specific search for urate crystals. (orig.)

  15. Radiographic study of the odontoma

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Hyung Kyu [Department of Oral Radiology, College of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    1983-11-15

    The author studied clinically and radiologically 55 cases which had been diagnosed as odontoma in SNUDH. The obtained results were as follows: 1. In sex distribution, there was no prevalence in both sexes. And the incidence was the highest in the 2nd decade (16 patient, 29%). 2. There were 42 cases of compound odontoma (76%) and 13 cases of complex odontoma (24%). In most cases, compound odontoma was located at the anterior portion (34 cases, 81%) and complex odontoma at the posterior portions (9 cases, 69%). 3. There was no apparent clinical symptom in compound odontoma (83%), but in complex odontoma, 80% of cases show swelling. 4. The adjacent root resorption was not observed in any case. 5. Five cases radiographically diagnosed as cystic odontoma were not confirmed histopathologically.

  16. Radiographic evaluation of hallux valgus

    International Nuclear Information System (INIS)

    Richardson, M.L.; Hansen, S.T.; Kilcoyne, R.F.

    1987-01-01

    This paper presents the common preoperative and postoperative findings in hallux valgus, a common foot disorder of multiple etiologies, which can lead to significant foot pain and deformity. Little has been published in radiologic literature about the proper initial radiographic workup and the postoperative follow-up of this very common and very treatable cause of foot pain. Besides the primary findings of varus angulation of the first metatarsal and valgus angulation of the great toe, one may also see dorsal slaying of the first metatarsal head. As increased weight is borne by the central metatarsals, they may develop hyperostosis and stress fractures. Angular deformities of the hallux sesamoid joint and lesser toes may also be seen

  17. Hydrodynamics and stellar winds an introduction

    CERN Document Server

    Maciel, Walter J

    2014-01-01

    Stellar winds are a common phenomenon in the life of stars, from the dwarfs like the Sun to the red giants and hot supergiants, constituting one of the basic aspects of modern astrophysics. Stellar winds are a hydrodynamic phenomenon in which circumstellar gases expand towards the interstellar medium. This book presents an elementary introduction to the fundamentals of hydrodynamics with an application to the study of stellar winds. The principles of hydrodynamics have many other applications, so that the book can be used as an introduction to hydrodynamics for students of physics, astrophysics and other related areas.

  18. Hydrodynamic interactions in active colloidal crystal microrheology.

    Science.gov (United States)

    Weeber, R; Harting, J

    2012-11-01

    In dense colloids it is commonly assumed that hydrodynamic interactions do not play a role. However, a found theoretical quantification is often missing. We present computer simulations that are motivated by experiments where a large colloidal particle is dragged through a colloidal crystal. To qualify the influence of long-ranged hydrodynamics, we model the setup by conventional Langevin dynamics simulations and by an improved scheme with limited hydrodynamic interactions. This scheme significantly improves our results and allows to show that hydrodynamics strongly impacts the development of defects, the crystal regeneration, as well as the jamming behavior.

  19. Radiographic evaluation of degenerative joint disease in horses: interpretive principles

    International Nuclear Information System (INIS)

    Widmer, W.R.; Blevins, W.E.

    1994-01-01

    Degenerative joint disease in horses is characterized by the progressive deterioration of articular cartilage of synovial joints. The morbidity associated with degenerative joint disease, particularly the loss of function in pleasure and performance horses, costs horse owners millions of dollars each year. Although new drugs, such as polysulfated glycosaminoglycans and hyaluronic acid, are available for the treatment of patients with degenerative joint disease, the success of therapy depends on early diagnosis. Diagnostic imaging strategies, therefore, should focus on accurate and timely diagnosis of degenerative joint disease to provide prompt therapy. Early identification of degenerative joint disease is also beneficial because the use and/or training methods of affected patients may be altered, possibly limiting the progression of the disease. The pathogenesis of degenerative joint disease is complex and multifactorial. Current evidence suggests that initiating factors lead to a final common pathway-breakdown of articular cartilage. There are many diagnostic tests that aid practitioners in detecting degenerative joint disease; however, the most important imaging technique is radiography. During the early stages of the disease, radiographic changes may be slight; therefore, it is essential that practitioners have adequate equipment to obtain high-quality radiographs. Thinning of the joint space, osteophytosis, enthesopathy, changes in subchondral bone, and increased synovium and synovia provide radiographic evidence of degenerative joint disease. By understanding the pathophysiology of the disease and how technical alterations affect the subtle radiographic changes, practitioners can more accurately diagnose degenerative joint disease during its early stages and institute proper therapy

  20. Assessment of radiation protection practices among radiographers in Lagos, Nigeria.

    Science.gov (United States)

    Eze, Cletus Uche; Abonyi, Livinus Chibuzo; Njoku, Jerome; Irurhe, Nicholas Kayode; Olowu, Oluwabola

    2013-11-01

    Use of ionising radiation in diagnostic radiography could lead to hazards such as somatic and genetic damages. Compliance to safe work and radiation protection practices could mitigate such risks. The aim of the study was to assess the knowledge and radiation protection practices among radiographers in Lagos, Nigeria. The study was a prospective cross sectional survey. Convenience sampling technique was used to select four x-ray diagnostic centres in four tertiary hospitals in Lagos metropolis. Data were analysed with Epi- info software, version 3.5.1. Average score on assessment of knowledge was 73%. Most modern radiation protection instruments were lacking in all the centres studied. Application of shielding devices such as gonad shield for protection was neglected mostly in government hospitals. Most x-ray machines were quite old and evidence of quality assurance tests performed on such machines were lacking. Radiographers within Lagos metropolis showed an excellent knowledge of radiation protection within the study period. Adherence to radiation protection practices among radiographers in Lagos metropolis during the period studied was, however, poor. Radiographers in Lagos, Nigeria should embrace current trends in radiation protection and make more concerted efforts to apply their knowledge in protecting themselves and patients from harmful effects of ionising radiation.

  1. Effect of display type and room illuminance in chest radiographs

    International Nuclear Information System (INIS)

    Liukkonen, Esa; Jartti, Airi; Haapea, Marianne; Oikarinen, Heljae; Ahvenjaervi, Lauri; Mattila, Seija; Nevala, Terhi; Palosaari, Kari; Perhomaa, Marja; Nieminen, Miika T.

    2016-01-01

    To compare diagnostic accuracy in the detection of subtle chest lesions on digital chest radiographs using medical-grade displays, consumer-grade displays, and tablet devices under bright and dim ambient light. Five experienced radiologists independently assessed 50 chest radiographs (32 with subtle pulmonary findings and 18 without apparent findings) under bright (510 lx) and dim (16 lx) ambient lighting. Computed tomography was used as the reference standard for interstitial and nodular lesions and follow-up chest radiograph for pneumothorax. Diagnostic accuracy and sensitivity were calculated for assessments carried out in all displays and compared using the McNemar test. The level of significance was set to p < 0.05. Significant differences in sensitivity between the assessments under bright and dim lighting were found among consumer-grade displays in interstitial opacities with, and in pneumothorax without, Digital Imaging and Communication in Medicine-Grayscale Standard Display Function (DICOM-GSDF) calibration. Compared to 6 megapixel (MP) display under bright lighting, sensitivity in pneumothorax was lower in the tablet device and the consumer-grade display. Sensitivity in interstitial opacities was lower in the DICOM-GSDF calibrated consumer-grade display. A consumer-grade display with or without DICOM-GSDF calibration or a tablet device is not suitable for reading digital chest radiographs in bright lighting. No significant differences were observed between five displays in dim light. (orig.)

  2. Glass Foreign Body Hand Radiograph

    Directory of Open Access Journals (Sweden)

    Hamid Ehsani-Nia, DO

    2018-04-01

    Full Text Available History of present illness: A 27-year-old female sustained an injury to her left hand after she tripped and fell on a vase. She presented to the emergency department (ED complaining of pain over the laceration. Upon examination, patient presented with multiple small abrasions of the medial aspect of the left 5thdigit that are minimally tender. Additionally, she has one 0.5cm linear laceration of the medial aspect of the 5thmetacarpal with severe tenderness in the area and palpable underlying foreign body. Significant findings: Left hand plain radiography demonstrated a subcutaneous foreign body medial to the 5thmetacarpal that is radiopaque, trapezoidal in shape, and measures approximately 11mm x 3mm. Discussion: Laceration repairs are amongst the most common procedures in the emergency department; however, consideration for foreign body is often underdiagnosed. Imaging is performed in only about 11% of all traumatic wounds in the ED.1 Of those injuries relating to the hand that are subsequently imaged, about 15% are found to have a foreign body.2,3 Additionally, it is estimated that foreign bodies are present in 7% to 8.7% of all wounds caused by glass objects.4,5 Glass is among the most common foreign bodies in lacerations, and fortunately they are radiopaque and relatively well visualized radiographically. It has been demonstrated that 2mm glass foreign bodies have a 99% detection rate with radiography, and 1mm glass foreign bodies an 83% detection rate.6 Patient perception of foreign body has a positive predictive value of 31%, making it a poor source in influencing clinical decision-making to obtain wound radiographs.3 Clinicians should have a high suspicion for foreign body in lacerations, particularly those caused by glass, and utilize close physical examination and imaging for evaluation. Topics: Radiography, glass, foreign body, trauma

  3. Dental Radiographs Ordered by Dental Professionals: an ...

    African Journals Online (AJOL)

    Conclusions: Even in resource limited settings dental caries is still the regular indication for taking dental radiographs, and periapical views are the most frequent type of radiograph ordered. Maxillary central incisors and mandibular molars were types of teeth commonly x-rayed mainly due to the aesthetic importance of the ...

  4. Consultant breast radiographers: Where are we now?

    International Nuclear Information System (INIS)

    Rees, Zebby

    2014-01-01

    Introduction: The aim of this study is to: • Evaluate the current role of the consultant breast radiographer. • Compare current practice with the four key components for consultant practice. • Gauge the support of radiologist colleagues. • Determine the other professional commitments involved with the role. This study could be the precursor for a macro study of all consultant radiographer practice in other specialities. Methodology: Methodology used was a comparative ethnographic study. Questionnaires to the 24 consultant breast radiographers currently in post, and consultant breast radiologists, who work with them, were conducted. Data collection was a qualitative thematic approach. Conclusion: Consultant breast radiographers provide high quality care to patients through excellent clinical practice, leadership and good communication. However, this study shows hospital Trusts emphasis for non medical consultants is for clinical practice first. Some radiologists are still a barrier to progression for consultant breast radiographers, and radiologists have a big influence in recruitment decisions. Consultant breast radiographer posts are well established, their numbers are increasing through recognition of the role and of their abilities and performance. Consultant breast radiographers state that becoming a consultant is the major achievement of their career, proving the Society of Radiographers' vision of the four-tier career structure has been well received by the radiography profession

  5. Radiographic arthrosis after elbow trauma: interobserver reliability.

    NARCIS (Netherlands)

    Lindenhovius, A.; Karanicolas, P.J.; Bhandari, M.; Ring, D.; Kampen, A. van; et al.,

    2012-01-01

    PURPOSE: This study measured observer variation in radiographic rating of elbow arthrosis. METHODS: Thirty-seven independent orthopedic surgeons graded the extent of elbow arthrosis in 20 consecutive sets of plain radiographs, according to the Broberg and Morrey rating system (grade 0, normal joint;

  6. Influence of radiographic contrast media on phagocytosis

    International Nuclear Information System (INIS)

    Rasmussen, F.; Georgsen, J.; Grunnet, N.; Aalborg Sygehus

    1988-01-01

    To evaluate the influence of radiographic contrast media (CM) on human polymorphonuclear leucocytes (PML), the ability of these cells to ingest latex particles after in vitro exposure to five different radiographic contrast media was investigated. All CM inhibited the phagocytic properties of PML. The inhibition was dose dependent. The inhibitory effect was partly due to hyperosmolality but CM specific inhibition was also evident. (orig.)

  7. Chest Radiographic Findings in Newly Diagnosed Pulmonary ...

    African Journals Online (AJOL)

    Five hundred newly diagnosed cases of Pulmonary Tuberculosis were treated with directly observed short-course treatment and 100 of them had chest radiographic examination done. The various chest radiographic patterns in the 100 subjects were studied and included: Fluffy exudative changes 80(80%), fibrosis 70(70%) ...

  8. Radiographic Arthrosis After Elbow Trauma: Interobserver Reliability

    NARCIS (Netherlands)

    Lindenhovius, Anneluuk; Karanicolas, Paul Jack; Bhandari, Mohit; Ring, David; Allan, Cristopher; Axelrod, Terry; Baratz, Mark; Beingessner, Daphne; Cassidy, Charles; Coles, Chad; Conflitti, Joe; Rocca, Gregory Della; van Dijk, C. Niek; Elmans, L. H. G. J.; Feibe, Roger; Frihagen, Frede; Gosens, Taco; Greenberg, Jeffrey; Grosso, Elena; Harness, Neil; van der Heide, Huub; Jeray, Kyle; Kalainov, David; van Kampen, Albert; Kawamura, Sumito; Kloen, Peter; McCormac, Bob; McKee, Michael; Page, Richard; Pesantez, Rodrigo; Peters, Anil; Petrisor, Brad; Poolman, Rudolf; Richardson, Martin; Seiler, John; Swiontkowski, Marc; Trumble, Thomas; Wright, Thomas; Zalavras, Charalampos; Zura, Robert

    2012-01-01

    Purpose This study measured observer variation in radiographic rating of elbow arthrosis. Methods Thirty-seven independent orthopedic surgeons graded the extent of elbow arthrosis in 20 consecutive sets of plain radiographs, according to the Broberg and Morrey rating system (grade 0, normal joint;

  9. Validity of radiographic assessment of ankylosis

    International Nuclear Information System (INIS)

    Stenvik, A.; Beyer-Olsen, E.; Aabyholm, F.; Haanaes, H.R.; Gerner, N.W.

    1990-01-01

    The accuracy and sensitivity of radiographic assessments of reactive processes in dental tissues were evaluated by comparison of radiographs and histologic sections. Experimental lesions inflicted on the roots of 10 monkey incisors had been observed by means of serially obtained radiographs over a period of 315 to 370 days. The material was used for evaluation of radiographic assessment of ankylosis. For comparative purposes, assessment of the experimental lesion penetrating to the pulp and periapical radiolucency was added. True and falsely positive or negative recordings formed the basis for calculation of the accuracy and sensitivity of the radiographic assessment. The sensitivity, or the obsevers ability to detect the actual changes, was high for pulp penetration, intermediate for inflammation, and low for ankylosis. 6 refs., 3 figs., 2 tabs

  10. Consultant radiographers: Profile of the first generation

    International Nuclear Information System (INIS)

    Forsyth, Lesley J.; Maehle, Valerie

    2010-01-01

    Aim: The aim of this research is to examine the profile of first generation consultant radiographers: their demographics, educational backgrounds, qualifications and training, career experience and progression, teaching, lecturing and research activities. Method: Participant recruitment was drawn from the Society and College of Radiographers consultant radiographer group. Data collection involved a self-administered paper based and web based questionnaire. Results: Participant response rate of 55% (n = 11). Conclusions: The profile of the first consultant radiographer cohort reflects a diverse and eclectic mix. While some aspects of their development such as educational background, clinical training and skills enhancement are comparable to nurse consultants, clinical experience and employment history show some differences. Commitment to development of expert clinical skills is evident within the profile of the first generation cohort of consultant radiographers however research and leadership training are not strong features.

  11. Consultant radiographers: Profile of the first generation

    Energy Technology Data Exchange (ETDEWEB)

    Forsyth, Lesley J., E-mail: l.forsyth@rgu.ac.u [School of Health Sciences, Robert Gordon University, Aberdeen, AB10 7QG (United Kingdom); Maehle, Valerie [Faculty of Health and Social Care, Robert Gordon University, Aberdeen, AB10 7QG (United Kingdom)

    2010-11-15

    Aim: The aim of this research is to examine the profile of first generation consultant radiographers: their demographics, educational backgrounds, qualifications and training, career experience and progression, teaching, lecturing and research activities. Method: Participant recruitment was drawn from the Society and College of Radiographers consultant radiographer group. Data collection involved a self-administered paper based and web based questionnaire. Results: Participant response rate of 55% (n = 11). Conclusions: The profile of the first consultant radiographer cohort reflects a diverse and eclectic mix. While some aspects of their development such as educational background, clinical training and skills enhancement are comparable to nurse consultants, clinical experience and employment history show some differences. Commitment to development of expert clinical skills is evident within the profile of the first generation cohort of consultant radiographers however research and leadership training are not strong features.

  12. Chest radiographic findings in acute paraquat poisoning

    Energy Technology Data Exchange (ETDEWEB)

    Na, Gyeong Gyun; Lee, Mi Sook; Kim, Hee Jun; Sun, In O [Presbyterian Medical Center, Jeonju (Korea, Republic of)

    2016-01-15

    To describe the chest radiographic findings of acute paraquat poisoning. 691 patients visited the emergency department of our hospital between January 2006 and October 2012 for paraquat poisoning. Of these 691, we identified 56 patients whose initial chest radiographs were normal but who developed radiographic abnormalities within one week. We evaluated their radiographic findings and the differences in imaging features based on mortality. The most common finding was diffuse consolidation (29/56, 52%), followed by consolidation with linear and nodular opacities (18/56, 32%), and combined consolidation and pneumomediastinum (7/56, 13%). Pleural effusion was noted in 17 patients (30%). The two survivors (4%) showed peripheral consolidations, while the 54 patients (96%) who died demonstrated bilateral (42/54, 78%) or unilateral (12/54, 22%) diffuse consolidations. Rapidly progressing diffuse pulmonary consolidation was observed within one week on follow-up radiographs after paraquat ingestion in the deceased, but the survivors demonstrated peripheral consolidation.

  13. Invariant description of solutions of hydrodynamic-type systems in hodograph space: hydrodynamic surfaces

    International Nuclear Information System (INIS)

    Ferapontov, E.V.

    2002-01-01

    Hydrodynamic surfaces are solutions of hydrodynamic-type systems viewed as non-parametrized submanifolds of the hodograph space. We propose an invariant differential-geometric characterization of hydrodynamic surfaces by expressing the curvature form of the characteristic web in terms of the reciprocal invariants. (author)

  14. CHASM Challenge Problem: Lagrangian Hydrodynamics

    Energy Technology Data Exchange (ETDEWEB)

    Hornung, R [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Keasler, J [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Gokhale, M [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2010-09-10

    Computer simulations of many science and engineering problems require modeling the equations of hydrodynamics which describe the motion of materials relative to each other induced by various forces. Many important DoD simulation problems involve complex multi-material systems that undergo large deformations. Examples include the analysis of armor defense, penetration mechanics, blast effects, structural integrity, and conventional munitions such as shaped charges and explosively formed projectiles. Indeed, the original motivation for developing codes that solve the equations of hydrodynamics, herein referred to as “hydrocodes”, was to solve problems with defense applications. The FY2010 Requirements Analysis Report issued by the DoD High Performance Computing Modernization Program (HPCMP) Office shows that a major portion of DoD HPC activities involves hydrocodes [HPCMP2010]. The report surveyed 496 projects across the Services and various Agencies, representing 4,050 HPCMP users at more than 125 locations, including government, contractors, and academia, and grouped each project into one of ten categories.

  15. The radiographic acromiohumeral interval is affected by arm and radiographic beam position

    Energy Technology Data Exchange (ETDEWEB)

    Fehringer, Edward V.; Rosipal, Charles E.; Rhodes, David A.; Lauder, Anthony J.; Feschuk, Connie A.; Mormino, Matthew A.; Hartigan, David E. [University of Nebraska Medical Center, Department of Orthopaedic Surgery and Rehabilitation, Omaha, NE (United States); Puumala, Susan E. [Nebraska Medical Center, Department of Preventive and Societal Medicine, Omaha, NE (United States)

    2008-06-15

    The objective was to determine whether arm and radiographic beam positional changes affect the acromiohumeral interval (AHI) in radiographs of healthy shoulders. Controlling for participant's height and position as well as radiographic beam height and angle, from 30 right shoulders of right-handed males without shoulder problems four antero-posterior (AP) radiographic views each were obtained in defined positions. Three independent, blinded physicians measured the AHI to the nearest millimeter in 120 randomized radiographs. Mean differences between measurements were calculated, along with a 95% confidence interval. Controlling for observer effect, there was a significant difference between AHI measurements on different views (p<0.01). All pair-wise differences were statistically significant after adjusting for multiple comparisons (all p values <0.01). Even in healthy shoulders, small changes in arm position and radiographic beam orientation affect the AHI in radiographs. (orig.)

  16. Hydrodynamic analysis and simulation of a flow cell ammonia electrolyzer

    International Nuclear Information System (INIS)

    Diaz, Luis A.; Botte, Gerardine G.

    2015-01-01

    Highlights: • NH_3 electrooxidation mechanism was validated in a bench scale electrolyzer. • All kinetic parameters for NH_3 electro-oxidation were calculated and verified. • Hydrodynamic behavior of the NH_3 electrolyzer was properly described as a CSTR. • CSTR model was successfully applied to simulate a flow ammonia electrolyzer. - Abstract: The hydrodynamic analysis and simulation of a non-ideal single pass flow cell alkaline ammonia electrolyzer was performed after the scale-up of a well-characterized deposited polycrystalline Pt on Ni anode. The hydrodynamic analysis was performed using the residence time distribution (RTD) test. The results of the hydrodynamic investigation provide additional insights for the kinetic analysis of the ammonia electrooxidation reaction on polycrystalline Pt electrocatalysts -which are typically obtained under controlled flow regime, e.g., rotating disk electrode- by including the flow non-uniformity present in the electrolyzer. Based on the RTD function, the ammonia electrolyzer performance was simulated as a non-steady stirred tank reactor (CSTR) and the unknown kinetic parameters were obtained by fitting the simulation results with an experimental current profile, obtaining an adequate prediction of the ammonia conversion. This simplified approach for the simulation of the ammonia electrolyzer could be implemented in process simulation packages and could be used for the design and scale-up of the process for hydrogen production and wastewater remediation.

  17. Diagnostic value of the chest radiograph in asymptomatic neonates with a cardiac murmur

    International Nuclear Information System (INIS)

    Oeppen, R.S.; Fairhurst, J.J.; Argent, J.D.

    2002-01-01

    AIM: To establish the diagnostic accuracy and diagnostic usefulness of the chest radiograph in asymptomatic neonates with cardiac murmurs. PATIENTS AND METHODS: The chest radiographs of 68 asymptomatic neonates with cardiac murmurs were analysed retrospectively. The radiographs were anonymized and then evaluated for the presence or absence of cardiac disease by six radiologists, three who regularly interpret neonatal chest radiographs and three who do so infrequently. The eventual diagnosis for each neonate and the impact of the chest radiograph and original report on patient management were established by review of the clinical case notes. RESULTS: The results for each observer were expressed in 2 x 2 contingency tables and statistical analysis was performed using Fisher's exact test. The radiologists who were experienced in reporting neonatal chest radiographs achieved statistically significant results (P = 0.003, P = 0.002 andP = 0.007) compared with those who were less experienced (P = 0.13, P = 0.16 andP = 0.09). Review of the case notes established that the chest radiograph and original report did not influence clinical management in any of the 68 cases studied. CONCLUSIONS: Radiologists who frequently report neonatal chest radiographs achieve high accuracy in differentiating cardiac from non-cardiac disease. However, inaccuracies are unavoidable as radiological evidence of cardiac disease is often not present. A false-positive result could cause undue anxiety while a false-negative report could result in the omission of further investigations. Furthermore, a chest radiograph is unlikely to provide the definitive diagnosis. Chest radiographs did not appear to influence patient management in this study and cannot be recommended in the initial evaluation of the asymptomatic neonate with a heart murmur. Oeppen, R.S. et al. (2002)

  18. Digital subtraction radiographic evaluation of the standardize periapical intraoral radiographs

    International Nuclear Information System (INIS)

    Cho, Bong Hae; Nah, Kyung Soo

    1993-01-01

    The geometrically standardized intraoral radiographs using 5 occlusal registration material were taken serially from immediate, 1 day, 2, 4, 8, 12 and 16 weeks after making the bite blocks. The qualities of those subtracted images were evaluated to check the degree of reproducibility of each impression material. The results were as follows: 1. The standard deviations of the grey scales of the overall subtracted images were 4.9 for Exaflex, 7.2 for Pattern resin, 9.0 for Tooth Shade Acrylic, 12.2 for XCP only, 14.8 for Impregum. 2. The standard deviation of the grey scales of the overall subtracted images were grossly related to those of the localized horizontal line of interest. 3. Exaflex which showed the best subtracted image quality had 15 cases of straight, 14 cases of wave, 1 case of canyon shape. Impregum which showed the worst subtracted image quality had 4 cases of straight, 8 cases of wave, 18 cases of canyon shape respectively.

  19. Radiographic Evidence of Hip Microinstability in Elite Ballet.

    Science.gov (United States)

    Mitchell, Ronald J; Gerrie, Brayden J; McCulloch, Patrick C; Murphy, Andrew J; Varner, Kevin E; Lintner, David M; Harris, Joshua D

    2016-06-01

    To determine prevalence, magnitude, and predisposing radiographic features of hip subluxation in elite ballet dancers. A cross-sectional investigation of professional male and female ballet dancers was performed using 5 plain radiographs. A "splits" anteroposterior (AP) radiograph was performed with legs abducted parallel to the trunk in the coronal plane (splits position; grand écart facial). Hip center position (HCP) was measured on standing AP pelvis and AP pelvis splits views and the difference calculated (subluxation distance) to determine prevalence and magnitude of femoral head subluxation. Student t test compared HCP on AP pelvis and splits radiographs. Pearson correlations were used to correlate splits HCP with radiographic measures of femoroacetabular impingement and dysplasia. Analyzing 47 dancers (21 men, 26 women; 23.8 ± 5.4 years), mean HCP on standing AP pelvis was 9.39 ± 3.33 mm versus 10.8 ± 2.92 mm on splits radiograph, with mean subluxation distance of 1.41 mm (P = .035). Forty-two dancers' femoral heads translated laterally with splits positioning, and 17 dancers (36%) exhibited a "vacuum sign" (bilateral in 71% of subjects with at least 1 hip vacuum sign). There was strong positive correlation (r = 0.461, P = .001) with splits HCP and alpha angle (Dunn 45°), and moderate negative correlation (r = -0.332, P = .022) with subluxation distance and neck-shaft angle. In men, splits HCP increased as lateral center edge angle (CEA) decreased (r = -0.437, P = .047), as anterior CEA decreased (r = -0.482, P = .027), as Tönnis angle increased (r = 0.656, P = .001), and as femoral head extrusion index increased (r = 0.511, P = .018). In women, there was moderate negative correlation (r = -0.389, P = .049) with subluxation distance and neck-shaft angle. Hip subluxation occurs during splits in most professional ballet dancers, with a significantly greater magnitude of subluxation in women than men. Subluxation magnitude

  20. On the Hydrodynamics of Anomalocaris Tail Fins.

    Science.gov (United States)

    Sheppard, K A; Rival, D E; Caron, J-B

    2018-04-25

    Anomalocaris canadensis, a soft-bodied stem-group arthropod from the Burgess Shale, is considered the largest predator of the Cambrian period. Thanks to a series of lateral flexible lobes along its dorso-ventrally compressed body, it is generally regarded as an efficient swimmer, well-adapted to its predatory lifestyle. Previous theoretical hydrodynamic simulations have suggested a possible optimum in swimming performance when the lateral lobes performed as a single undulatory lateral fin, comparable to the pectoral fins in skates and rays. However, the role of the unusual fan-like tail of Anomalocaris has not been previously explored. Swimming efficiency and maneuverability deduced from direct hydrodynamic analysis are here studied in a towing tank facility using a three-vane physical model designed as an abstraction of the tail fin. Through direct force measurements, it was found that the model exhibited a region of steady-state lift and drag enhancement at angles of attack greater than 25° when compared to a triangular-shaped reference model. This would suggest that the resultant normal force on the tail fin of Anomalocaris made it well-suited for turning maneuvers, giving it the ability to turn quickly and through small radii of curvature. These results are consistent with an active predatory lifestyle, although detailed kinematic studies integrating the full organism, including the lateral lobes, would be required to test the effect of the tail fin on overall swimming performance. This study also highlights a possible example of evolutionary convergence between the tails of Anomalocaris and birds, which, in both cases, are well-adapted to efficient turning maneuvers.

  1. Hydrodynamic Overview at Hot Quarks 2016

    International Nuclear Information System (INIS)

    Noronha-Hostler, Jacquelyn

    2017-01-01

    Event-by-event relativistic hydrodynamics has been extremely successful in describing flow observables in heavy-ion collisions. However, the initial state and viscosity simultaneously affect comparisons to data so a discussion of experimental observables that help to distinguish the two follows. Specific problems that arise in the hydrodynamical modeling at the Beam Energy Scan are also addressed. (paper)

  2. Two-fluid hydrodynamic model for semiconductors

    DEFF Research Database (Denmark)

    Maack, Johan Rosenkrantz; Mortensen, N. Asger; Wubs, Martijn

    2018-01-01

    The hydrodynamic Drude model (HDM) has been successful in describing the optical properties of metallic nanostructures, but for semiconductors where several different kinds of charge carriers are present an extended theory is required. We present a two-fluid hydrodynamic model for semiconductors...

  3. Gamma radiographic exposure time indicator

    International Nuclear Information System (INIS)

    Risbud, V.H.; Thiagarajan, A.; Gangadharan, P.

    1979-01-01

    In industrial radiography, with the proper selection of source and film, the radiographic quality depends very much on the exposure time, which in turn depends upon the source strength and the source to film distance. Conventional methods to arrive at correct exposure time involve time consuming calculations and in these methods the knowledge of the above mentioned parameters is imperative. An instrument to determine the required exposure time has been developed which indicates exposure times in about 30 secs. This covers two commonly used gamma radiography sources, viz., 192 Ir and 60 Co and six commonly used radiography films of different speeds. Knowledge of source strength and source to film distance is not required with the use of this instrument. With a knowledge of the total exposure required by the film to give the required sensitivity and by the measurement of radiation level at the film location, the correct exposure time is determined. The radiation level is measured by placing a GM counter behind the radiographic specimen at the film location. To match the responses of the film and the GM counter, the counter is incorporated in a suitably designed probe. In this instruments, an integrator to integrate the GM-pulses and a constant current integrator (timer) are started simultaneously. The voltage at the GM-pulse integrator is compared with a preselected voltage, (selected on the basis of film type, source, source strength and order of object thickness) by a comparator. The comparator is so adjusted that when the GM-pulse integrator voltage exceeds the preselected voltage, it switches its state and stops the integration of constant current. The constant current integrator output which is proportional to the time taken for the GM-pulse integrator to reach the preselected voltage, is read on a meter graduated in terms of exposure time. The instrument can measure exposure times from 5 minutes to 10 hours read in two ranges, the range-changing being automatic

  4. Reporting by radiographers: a policy and practice guide

    International Nuclear Information System (INIS)

    Paterson, Audrey M.; Price, Richard C.; Thomas, Adrian; Nuttall, Lorraine

    2004-01-01

    Reporting by radiographers and other non-medical staff has developed considerably in the past decade, and especially so since the College of Radiographers published its vision paper on reporting by radiographers, in 1997. It was felt necessary, therefore, to develop guidance to assist radiographers and others undertaking radiographic reporting. The guidance provided includes guidance on planning and implementing a reporting service using reporting radiographers; the education, continuing education and support required by reporting radiographers; quality and standards related to reporting; and the nature of a report. Broader issues that will need to be addressed as reporting by radiographers becomes the norm are also raised

  5. Radiographic and computed tomographic evaluation of otitis media in the dog

    International Nuclear Information System (INIS)

    Love, N.E.; Kramer, R.W.; Spodnick, G.J.; Thrall, D.E.

    1995-01-01

    The purpose of this study was to compare computed tomography (CT) and radiography in the identification of canine middle ear disease. Fourteen canine patients underwent a radiographic “bullae series” and CT examination of the tympanic bullae. Confirmation of otitis media was based on surgery. The overall diagnostic accuracy of CT and radiographs regarding the diagnosis of otitis media was similar. Although a marked difference was not detected between radiographs and CT for detecting otitis media using Youden's index values, CT was a more sensitive test for the detection of otitis media

  6. Agreement between radiographic and photographic trabecular patterns

    International Nuclear Information System (INIS)

    Korstjens, C.M.; Geraets, W.G.M.; Stelt, P.F. van der; Spruijt, R.J.; Mosekilde, L.

    1998-01-01

    Purpose: It has been hypothesized that photographs can facilitate the interpretation of the radiographic characteristics of trabecular bone. The reliability of these photographic and radiographic approaches has been determined, as have various agreements between the two approaches and their correlations with biomechanical characteristics. Material and Methods: Fourteen vertebral bodies were obtained at autopsy from 6 women and 8 men aged 22-76 years. Photographs (n=28) and radiographs (n=28) were taken of midsagittal slices from the third lumbar vertebra. The radiographs and photographs were digitized and the geometric properties of the trabecular architecture were then determined with a digital images analysis technique. Information on the compressive strength and ash density of the vertebral body was also available. Results: The geometric properties of both radiographs and photographs could be measured with a high degree of reliability (Cronbach's α>0.85). Agreement between the radiographic and photographic approaches was mediocre as only the radiographic measurements showed insignificant correlations (p<0.05) with the biomechanical characteristics. We suggest that optical phenomena may result in the significant correlations between the photographs and the biomechanical characteristics. Conclusion: For digital image processing, radiography offers a superior description of the architecture of trabecular bone to that offered by photography. (orig.)

  7. Agreement between radiographic and photographic trabecular patterns

    Energy Technology Data Exchange (ETDEWEB)

    Korstjens, C.M.; Geraets, W.G.M.; Stelt, P.F. van der [Dept. of Oral Radiology, Academic Centre for Dentistry, Amsterdam (Netherlands); Spruijt, R.J. [Div. of Psychosocial Research and Epidemiology, Netherlands Cancer Inst., Amsterdam (Netherlands); Mosekilde, L. [Dept. of Cell Biology, Univ. of Aarhus (Denmark)

    1998-11-01

    Purpose: It has been hypothesized that photographs can facilitate the interpretation of the radiographic characteristics of trabecular bone. The reliability of these photographic and radiographic approaches has been determined, as have various agreements between the two approaches and their correlations with biomechanical characteristics. Material and Methods: Fourteen vertebral bodies were obtained at autopsy from 6 women and 8 men aged 22-76 years. Photographs (n=28) and radiographs (n=28) were taken of midsagittal slices from the third lumbar vertebra. The radiographs and photographs were digitized and the geometric properties of the trabecular architecture were then determined with a digital images analysis technique. Information on the compressive strength and ash density of the vertebral body was also available. Results: The geometric properties of both radiographs and photographs could be measured with a high degree of reliability (Cronbach`s {alpha}>0.85). Agreement between the radiographic and photographic approaches was mediocre as only the radiographic measurements showed insignificant correlations (p<0.05) with the biomechanical characteristics. We suggest that optical phenomena may result in the significant correlations between the photographs and the biomechanical characteristics. Conclusion: For digital image processing, radiography offers a superior description of the architecture of trabecular bone to that offered by photography. (orig.)

  8. Radiographic markers - A reservoir for bacteria?

    International Nuclear Information System (INIS)

    Tugwell, Jenna; Maddison, Adele

    2011-01-01

    Introduction: Amongst the most frequently handled objects in the radiology department are radiographic markers. They are personal accessories used with every patient, and are kept in the radiographers pockets when not utilised. Upon enquiry it was discovered that many radiographers disregarded the potential of these accessories to become a vector for cross-contamination thus never or rarely clean them. The aims of this study were therefore to identify if radiographic markers are a reservoir for bacteria and to establish an effective cleaning method for decontaminating them. Methodology: 25 radiographers/student radiographers were selected for this study. Swabbing of their markers prior and post cleaning took place. The microbiology laboratory subsequently analyzed the results by quantifying and identifying the bacteria present. The participants also completed a closed questionnaire regarding their markers (e.g. frequency of cleaning and type of marker) to help specify the results gained from the swabbing procedure. Results: From the sample swabbed, 92% were contaminated with various organisms including Staphylococcus and Bacillus species, the amount of bacteria present ranged from 0 to >50 CFU. There were no significant differences between disinfectant wipes and alcohol gel in decontaminating the markers. Both successfully reduced their bacterial load, with 80% of the markers post cleaning having 0 CFU. Conclusion: The results indicated that radiographic markers can become highly contaminated with various organisms thus serve as a reservoir for bacteria. In addition, the markers need to be cleaned on a regular basis, with either disinfectant wipes or alcohol gel to reduce their bacterial load.

  9. Hemolytic potential of hydrodynamic cavitation.

    Science.gov (United States)

    Chambers, S D; Bartlett, R H; Ceccio, S L

    2000-08-01

    The purpose of this study was to determine the hemolytic potentials of discrete bubble cavitation and attached cavitation. To generate controlled cavitation events, a venturigeometry hydrodynamic device, called a Cavitation Susceptibility Meter (CSM), was constructed. A comparison between the hemolytic potential of discrete bubble cavitation and attached cavitation was investigated with a single-pass flow apparatus and a recirculating flow apparatus, both utilizing the CSM. An analytical model, based on spherical bubble dynamics, was developed for predicting the hemolysis caused by discrete bubble cavitation. Experimentally, discrete bubble cavitation did not correlate with a measurable increase in plasma-free hemoglobin (PFHb), as predicted by the analytical model. However, attached cavitation did result in significant PFHb generation. The rate of PFHb generation scaled inversely with the Cavitation number at a constant flow rate, suggesting that the size of the attached cavity was the dominant hemolytic factor.

  10. Deterministic hydrodynamics: Taking blood apart

    Science.gov (United States)

    Davis, John A.; Inglis, David W.; Morton, Keith J.; Lawrence, David A.; Huang, Lotien R.; Chou, Stephen Y.; Sturm, James C.; Austin, Robert H.

    2006-10-01

    We show the fractionation of whole blood components and isolation of blood plasma with no dilution by using a continuous-flow deterministic array that separates blood components by their hydrodynamic size, independent of their mass. We use the technology we developed of deterministic arrays which separate white blood cells, red blood cells, and platelets from blood plasma at flow velocities of 1,000 μm/sec and volume rates up to 1 μl/min. We verified by flow cytometry that an array using focused injection removed 100% of the lymphocytes and monocytes from the main red blood cell and platelet stream. Using a second design, we demonstrated the separation of blood plasma from the blood cells (white, red, and platelets) with virtually no dilution of the plasma and no cellular contamination of the plasma. cells | plasma | separation | microfabrication

  11. The hydrodynamic theory of detonation

    Science.gov (United States)

    Langweiler, Heinz

    1939-01-01

    This report derives equations containing only directly measurable constants for the quantities involved in the hydrodynamic theory of detonation. The stable detonation speed, D, is revealed as having the lowest possible value in the case of positive material velocity, by finding the minimum of the Du curve (u denotes the speed of the gases of combustion). A study of the conditions of energy and impulse in freely suspended detonating systems leads to the disclosure of a rarefaction front traveling at a lower speed behind the detonation front; its velocity is computed. The latent energy of the explosive passes into the steadily growing detonation zone - the region between the detonation front and the rarefaction front. The conclusions lead to a new definition of the concept of shattering power. The calculations are based on the behavior of trinitrotoluene.

  12. Fluctuating nonlinear hydrodynamics of flocking

    Science.gov (United States)

    Yadav, Sunil Kumar; Das, Shankar P.

    2018-03-01

    Starting from a microscopic model, the continuum field theoretic description of the dynamics of a system of active ingredients or "particles" is presented. The equations of motion for the respective collective densities of mass and momentum follow exactly from that of a single element in the flock. The single-particle dynamics has noise and anomalous momentum dependence in its frictional terms. The equations for the collective densities are averaged over a local equilibrium distribution to obtain the corresponding coarse grained equations of fluctuating nonlinear hydrodynamics (FNH). The latter are the equations used frequently for describing active systems on the basis of intuitive arguments. The transport coefficients which appear in the macroscopic FNH equations are determined in terms of the parameters of the microscopic dynamics.

  13. Hydrodynamics and phases of flocks

    International Nuclear Information System (INIS)

    Toner, John; Tu Yuhai; Ramaswamy, Sriram

    2005-01-01

    We review the past decade's theoretical and experimental studies of flocking: the collective, coherent motion of large numbers of self-propelled 'particles' (usually, but not always, living organisms). Like equilibrium condensed matter systems, flocks exhibit distinct 'phases' which can be classified by their symmetries. Indeed, the phases that have been theoretically studied to date each have exactly the same symmetry as some equilibrium phase (e.g., ferromagnets, liquid crystals). This analogy with equilibrium phases of matter continues in that all flocks in the same phase, regardless of their constituents, have the same 'hydrodynamic'-that is, long-length scale and long-time behavior, just as, e.g., all equilibrium fluids are described by the Navier-Stokes equations. Flocks are nonetheless very different from equilibrium systems, due to the intrinsically nonequilibrium self-propulsion of the constituent 'organisms'. This difference between flocks and equilibrium systems is most dramatically manifested in the ability of the simplest phase of a flock, in which all the organisms are, on average moving in the same direction (we call this a 'ferromagnetic' flock; we also use the terms 'vector-ordered' and 'polar-ordered' for this situation) to exist even in two dimensions (i.e., creatures moving on a plane), in defiance of the well-known Mermin-Wagner theorem of equilibrium statistical mechanics, which states that a continuous symmetry (in this case, rotation invariance, or the ability of the flock to fly in any direction) can not be spontaneously broken in a two-dimensional system with only short-ranged interactions. The 'nematic' phase of flocks, in which all the creatures move preferentially, or are simply oriented preferentially, along the same axis, but with equal probability of moving in either direction, also differs dramatically from its equilibrium counterpart (in this case, nematic liquid crystals). Specifically, it shows enormous number fluctuations, which

  14. Anomalous hydrodynamics kicks neutron stars

    Energy Technology Data Exchange (ETDEWEB)

    Kaminski, Matthias, E-mail: mski@ua.edu [Department of Physics and Astronomy, University of Alabama, Tuscaloosa, AL 35487 (United States); Department of Physics and Astronomy, University of Victoria, Victoria, BC, V8P 5C2 (Canada); Uhlemann, Christoph F. [Department of Physics, University of Washington, Seattle, WA 98195 (United States); Bleicher, Marcus [Frankfurt Institute for Advanced Studies, Goethe-Universität Frankfurt (Germany); Institut für Theoretische Physik, Goethe Universität Frankfurt (Germany); Schaffner-Bielich, Jürgen [Institut für Theoretische Physik, Goethe Universität Frankfurt (Germany)

    2016-09-10

    Observations show that, at the beginning of their existence, neutron stars are accelerated briskly to velocities of up to a thousand kilometers per second. We argue that this remarkable effect can be explained as a manifestation of quantum anomalies on astrophysical scales. To theoretically describe the early stage in the life of neutron stars we use hydrodynamics as a systematic effective-field-theory framework. Within this framework, anomalies of the Standard Model of particle physics as underlying microscopic theory imply the presence of a particular set of transport terms, whose form is completely fixed by theoretical consistency. The resulting chiral transport effects in proto-neutron stars enhance neutrino emission along the internal magnetic field, and the recoil can explain the order of magnitude of the observed kick velocities.

  15. Effects of Edentulism on Mandibular Morphology: Evaluation of Panoramic Radiographs

    Directory of Open Access Journals (Sweden)

    Rıdvan Okşayan

    2014-01-01

    Full Text Available Purpose. The objective of this study was to evaluate morphological changes of the mandible in edentulous and dentate subjects using panoramic radiographs. Materials and Methods. Panoramic radiographs were divided into the following three groups: Group I (completely edentulous group, Group II (old dentate group and Group III (young dentate group. The research parameters of gonial angle, condylar height, ramus height, ramus notch depth, and antegonial notch depth were measured on panoramic radiographs. The Kruskal-Wallis statistical test was used to determine significant differences in mandibular morphological parameters among the three groups. The Mann-Whitney U test was used to compare the subgroups. Results. Significant differences were found only in ramus height between three groups. According to the Mann-Whitney U test, a significant difference was exhibited among Groups I and II in the ramus height parameter. No significant differences were found in the gonial angle, condylar height, ramus notch depth, or antegonial notch depth when comparing the young dentate, old dentate, and completely edentulous subjects. Conclusions. Significant differences were found only in ramus height between the groups. Ramus height may be an indicator that changed by years and tooth loss. It must be considered that ramus height can be decreased in edentulism.

  16. Unicystic Jaw Lesions: A Radiographic Guideline

    Directory of Open Access Journals (Sweden)

    Giju George

    2010-01-01

    Full Text Available The unilocular radiolucencies remain the topic of much interest for the clinicians and histhopathologists for decades. Adequate use of diagnostic aids and careful observation will clinically help the dentist to arrive at a proper diagnosis and renders quality treatment to patients. Despite of the development of various cross-sectional imaging modalities, the radiograph still remains as the first and most important investigation. Jaw bone lesions, especially unilocular ones, are difficult to diagnose radiologically because of their similar radiographic appearance. It is, thus, very important for the clinician to have a sound knowledge of various radiographic features of the tooth and its supporting structures.

  17. A case of a found radiographic source

    International Nuclear Information System (INIS)

    Pucelj, B.; Korun, M.; Kavsek, D.; Kreft, Z.; Krizman, M.; Martincic, R.; Rosman, M.; Sutej, T.

    1996-01-01

    High dose-rate levels were detected outdoors in the vicinity of a bunker used for storage of radiographic sources in a plant which manufactures metallic products. The investigation revealed that radiation was due to a buried sealed radiographic source, containing 28 GBq of 137 Cs. A special republic radiological emergency team removed the source in a carefully planned operation. There was no evidence for overexposure of the population or of radiographic and other workers of the plant. The highest dose to the recovery team was 50 μSv

  18. Hydrodynamic dispersion within porous biofilms

    KAUST Repository

    Davit, Y.

    2013-01-23

    Many microorganisms live within surface-associated consortia, termed biofilms, that can form intricate porous structures interspersed with a network of fluid channels. In such systems, transport phenomena, including flow and advection, regulate various aspects of cell behavior by controlling nutrient supply, evacuation of waste products, and permeation of antimicrobial agents. This study presents multiscale analysis of solute transport in these porous biofilms. We start our analysis with a channel-scale description of mass transport and use the method of volume averaging to derive a set of homogenized equations at the biofilm-scale in the case where the width of the channels is significantly smaller than the thickness of the biofilm. We show that solute transport may be described via two coupled partial differential equations or telegrapher\\'s equations for the averaged concentrations. These models are particularly relevant for chemicals, such as some antimicrobial agents, that penetrate cell clusters very slowly. In most cases, especially for nutrients, solute penetration is faster, and transport can be described via an advection-dispersion equation. In this simpler case, the effective diffusion is characterized by a second-order tensor whose components depend on (1) the topology of the channels\\' network; (2) the solute\\'s diffusion coefficients in the fluid and the cell clusters; (3) hydrodynamic dispersion effects; and (4) an additional dispersion term intrinsic to the two-phase configuration. Although solute transport in biofilms is commonly thought to be diffusion dominated, this analysis shows that hydrodynamic dispersion effects may significantly contribute to transport. © 2013 American Physical Society.

  19. Consultant radiographer leadership - A discussion

    International Nuclear Information System (INIS)

    Hogg, Peter; Hogg, Dianne; Henwood, Suzanne

    2008-01-01

    Effective leadership can be defined in many ways and is an essential element of successful organisations; poor leadership can result in problems such as low staff morale, high staff turnover and reduced productivity. Effective leadership behaviours are well documented in the literature and various leadership models have been proposed that illustrate these behaviours. This discussion paper does not focus on any particular model. Instead it considers the 'Leadership Qualities Framework' which was developed specifically for use within the UK National Health Service. This framework draws upon a range of leadership models and as such it gives a broad indication of leadership behaviours. The framework comprises three components - 'personal qualities', 'setting direction' and 'delivering the service'. This paper commences with an argument as to why effective leadership is important in organisations generally, and specifically within healthcare organisations. Various examples of leadership are illustrated from within and outside the NHS in order to demonstrate effective leadership behaviours. The Leadership Qualities Framework is then examined, along with scenarios to illustrate effective leadership behaviours in context (i.e. within a healthcare organisation). Subsequent reflections on the scenarios aim to identify leadership behaviours that are explained within the framework. The final element of this paper draws on [limited] published evidence of where consultant radiographers have demonstrated effective leadership behaviours. In this section the published evidence is examined and reflected upon. At the end of the article we indicate additional reading for those who wish to further develop their theoretical and practical leadership skills

  20. Radiographic observation for tuberculous spondylitis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chul Se; Jung, Marn Kyoon; Kim, Byung Soo [College of Medicine, Busan National University, Busan (Korea, Republic of)

    1974-04-15

    Radiographic observation of 152 cases of tuberculous spondylitis selected from total 194 cases of tuberculous arthritis during the past 6 years and 8 months, was carried out to study. 1. The youngest one was 15 months old male infant of active tuberculous spondylitis. The active tuberculous spondylitis under 10 years of age were 50 percent (28 cases). 2. The ratio of male to female was 1.5:1 3. The most common site of involvement was the lumbar spine which was 44.1 percent of the total tuberculous spondylitis. The next were thoracic spine (33.6%), and thoraco-lumber spine (13.1%). 4. The most common roentgenographic findings are bony destructions of the vertebral bodies which were 97.4 percent. The next were joint space narrowing (93.4%), osteoporosis (79.6%), kyphosis (34.2%), fusion deformity of the vertebral body (25.7%), and cold abscess shadow (16.4%). 5. The most of patients (88.8%) had or have been pulmonary tuberculous lesions. 6. In annual incidence, the number of patients were not changed greatly.

  1. Radiographic evaluation of AIDS patients

    International Nuclear Information System (INIS)

    Le Blang, S.D.; Witheman, M.L.; Donovan Post, M.J.; Casillas, J.V.

    1995-01-01

    Morphological imaging, based on the use of various techniques including ultrasound, X-ray computed tomography (CT), and magnetic resonance imaging (MRI), plays an important role in the characterization, diagnosis and follow-up of patients with Human Immunodeficiency Virus (HIV) infection and Acquired Immunodeficiency Syndrome (AIDS). While the presence of thoracic infections, the most frequently observed illnesses in AIDS patients, can best be performed by using conventional chest films and CT, the assessment of cerebral involvement in AIDS patients - characterized by the presence of focal masses, demyelination, meningitis, and infarction - is best achieved using MRI. The work-up of patients with gastrointestinal symptoms should include the use of ultrasound for the evaluation of visceral involvement and lymphadenopathy, completed by CT to further characterize pathologic conditions in either the bowel or visceral organs. Ultrasound is the screening exam of choice in AIDS patients with suspected renal disease, but other methods may be necessary for the assessment of the complications due to pharmacological treatment. Musculoskeletal complications may require the combined use of all the above methods, since they may be caused by infections, tumors and rheumatologic illness. The use of the radiographic methods for the detection of the numerous forms of infections and malignancies in AIDS patients is described in detail for the various body districts

  2. Hydrodynamic manoeuvrability data of a flatfish type AUV

    DEFF Research Database (Denmark)

    Aage, Christian; Wagner Smitt, Leif

    1994-01-01

    Hydrodynamic manoeuvrability data of the flatfish type autonomous underwater vehicle (AUV) “MARIUS” are presented. “MARIUS” was developed under the EC MAST Programme as a vehicle for seabed inspection and environmental surveys in coastal waters. The AUV has an overall length of 4.5 m and is driven...... by two propellers and four thrusters. The data comprise added mass and inertia coefficients, damping, lift and drag coefficients of the vehicle and its control surfaces, as well as resistance and propulsion characteristics. The hydrodynamic data have been determined by full scale tests, using a towing...... tank equipped with a planar motion mechanism. A few free-sailing tests have been carried out as well. Application of the data and possible improvements of the shape of the vehicle are discussed...

  3. Design and evaluation of learning strategies for a group of radiographers in radiostereometric analysis (RSA).

    Science.gov (United States)

    Muharemovic, O; Troelsen, A; Thomsen, M G; Kallemose, T; Gosvig, K K

    2017-11-01

    The purpose of this study was to design and evaluate a radiostereometric analysis (RSA) program aimed at radiographers in order to increase their cognitive and practical skills, thereby increasing image quality and minimizing exposure repetition. Twenty radiographers were randomized into two identically sized study groups. Training consisted of a theoretical and practical workshop using a phantom. Tests were performed to compare the effect of training to nontraining, and the effect of time duration on the maintenance of RSA skills. The effect of training was measured by a written test and three defined parameters influencing image quality. Group A reduced significantly (p RSA X-ray training program where radiographers significantly improve their theoretical and practical skills in centering the CP closer to the CCF, NB and RP. A duration of up to two months after training does not influence the quality of participants' performance. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  4. Measured displacement coefficients of an adjustable hydrodynamic journal rotor bearing

    OpenAIRE

    Martin, J. K.

    2013-01-01

    In simulating a proposed machine tool grinding wheel design, a bearing system comprised a stationary spindle or shaft with fluid film bearings supporting a belt driven rotor. Two hydrodynamic bearings acted in parallel, and built into the shaft were the means to effect continuous pro-active adjustments to their performance characteristics during operation, irrespective of load, speed and other running conditions. The design is outlined, as is a specially constructed test rig for evaluating it...

  5. Reliability of the craniocervical posture assessment: visual and angular measurements using photographs and radiographs.

    Science.gov (United States)

    Gadotti, Inae C; Armijo-Olivo, Susan; Silveira, Anelise; Magee, David

    2013-01-01

    The purposes of this study were to determine the intrarater and interrater reliability of the craniocervical posture in a sagittal view using quantitative measurements on photographs and radiographs and to determine the agreement of the visual assessment of posture between raters. One photograph and 1 radiograph of the sagittal craniocervical posture were simultaneously taken from 39 healthy female subjects. Three angles were measured on the photographs and 10 angles on the radiographs of 22 subjects using Alcimage software (Alcimage; Uberlândia, MG, Brazil). Two repeated measurements were performed by 2 raters. The measurements were compared within and between raters to test the intrarater and interrater reliability, respectively. Intraclass correlation coefficient and SEM were used. κ Agreement was calculated for the visual assessment of 39 subjects using photographs and radiographs between 2 raters. Good to excellent intrarater and interrater intraclass correlation coefficient values were found on both photographs and radiographs. Interrater SEM was large and clinically significant for cervical lordosis photogrammetry and for 1 angle measuring cervical lordosis on radiographs. Interrater κ agreement for the visual assessment using photographs was poor (κ = 0.37). The raters were reliable to measure angles in photographs and radiographs to quantify craniocervical posture with exception of 2 angles measuring lordosis of the cervical spine when compared between raters. The visual assessment of posture between raters was not reliable. © 2013. Published by National University of Health Sciences All rights reserved.

  6. Qualification of a digital radiographic equipment for thin weld inspection

    International Nuclear Information System (INIS)

    Boulanger, G.; Furlan, J.

    1988-04-01

    The level of quality asked for welding plugs to fuel pins requires to test all the welds, that is to say about 200 000 welds of the fuel assemblies of the fast reactor Super-Phenix. X-ray radiography is one of the tests. Before the operation was done on a film by the personnel automatic selection of tested material and image processing are substituted to the film in the digital radiographic equipment IRENE. Main advantages are: elimination of human factor in defect appreciation, reliability of image processing and instant availability. On 1000 welds a good correlation is obtained between results on films and those of image processing [fr

  7. Radiographic features of appendiceal colic in children

    International Nuclear Information System (INIS)

    Schisgall, R.M.

    1986-01-01

    The concept of appendiceal colic was introduced in 1980 to explain the common problem of recurrent crampy abdominal pain (RAP) in children. Children with appendiceal colic often have inspissated casts of stool as foreign bodies of the appendix. The radiographic findings of 115 children operated upon for appendiceal colic have been reviewed. The radiographic features of this syndrom have included: filling defects of the appendix (83% incidence of inspissated casts of stool within the appendix); partial filling of the appendix (44% incidence of fecal casts); retained barium behind 72 h (92% incidence of fecal casts blocking egress of barium); non-visualization of the appendix (42% incidence of fecal casts); and distention of the appendix (100% incidence of fecal casts). The correlation of radiographic and operative findings will be presented. A rational approach to the radiographic workup of a child with RAP will be presented. (orig.)

  8. Radiographers and radiologists reporting plain radiograph requests from accident and emergency and general practice

    International Nuclear Information System (INIS)

    Brealey, S.D.; King, D.G.; Hahn, S.; Crowe, M.; Williams, P.; Rutter, P.; Crane, S.

    2005-01-01

    AIM: To assess selectively trained radiographers and consultant radiologists reporting plain radiographs for the Accident and Emergency Department (A and E) and general practitioners (GPs) within a typical hospital setting. METHODS: Two radiographers, a group of eight consultant radiologists, and a reference standard radiologist independently reported under controlled conditions a retrospectively selected, random, stratified sample of 400 A and E and 400 GP plain radiographs. An independent consultant radiologist judged whether the radiographer and radiologist reports agreed with the reference standard report. Clinicians then assessed whether radiographer and radiologist incorrect reports affected confidence in their diagnosis and treatment plans, and patient outcome. RESULTS: For A and E and GP plain radiographs, respectively, there was a 1% (95% confidence interval (CI) -2 to 5) and 4% (95% CI -1 to 8) difference in reporting accuracy between the two professional groups. For both A and E and GP cases there was an 8% difference in the clinicians' confidence in their diagnosis based on radiographer or radiologist incorrect reports. For A and E and GP cases, respectively, there was a 2% and 8% difference in the clinicians' confidence in their management plans based on radiographer or radiologist incorrect reports. For A and E and GP cases, respectively, there was a 1% and 11% difference in effect on patient outcome of radiographer or radiologist incorrect reports. CONCLUSION: There is the potential to extend the reporting role of selectively trained radiographers to include plain radiographs for all A and E and GP patients. Further research conducted during clinical practice at a number of sites is recommended

  9. Radiographic study of the hepatomegaly

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byung Soo [Busan National University College of Medicine, Pusan (Korea, Republic of)

    1980-06-15

    The author studied, with emphasis on the various radiographic projections, the 99 cases of liver enlargement, which underwent the barium meal upper gastrointestinal examinations for the purpose of pursuit of significance of liver enlargement and, at the same time were confirmed by other clinical and pathological methods at Busan National University Hospital for about 2 years from November 1977 to September 1979. The following results were obtained: 1. The incidence of liver enlargement was 63.3% (62 cases) in the 5th decade, which was most prevalent, 18.2% (18 cases) in the 3rd decade, 15.2% (15 cases) in the group over 60, and 3.0% (3 cases) in the age group below 20. Male to female sex ratio was 2 : 1. 2. The causes of the liver enlargement confirmed by the final diagnosis are as follows: Primary hepatic cancer 39 cases (39.3%), liver cirrhosis 30 cases (30.3%), chronic hepatitis 12 cases (12.1%), cancer of the biliary tract 6 cases (6.1%), hepatic fluke 6 cases (6.1%), metastatic tumors 3 cases (3.0%), and hepatic congestion 3 cases (3.0%) 3. In the prone view, the displacement of the duodenal bulb appeared in 18 cases (18.2%). 4. In the routine radiographs, the displacement of the stomach to the left and the pressure indentation of the lesser curvature were noted in 69 cases (69.7%) out of 99 cases. 5.In the left lateral recumbent view, the pressure indentation of the anterior border of the gastric body was seen in 96 cases (97.0%) among the 99 cases, the straightening in 30 cases (27.3%), the marked depression in 30 cases (30.3%), the moderate in 27 cases (27.3%), the minimal in 9 cases (9.1%). 6. Comparing the incidences of the roentgen findings of the liver enlargement in the various projections respectively, the displacement of the duodenal bulb was noted in 18 cases (18.3%) in the prone position. The erect position revealed the displacement of the stomach to the left and the pressure indentation in 57 cases (57.6%), the prone position in 51 cases (51

  10. Thickness Evaluation of Pipeline Using Density Profile on a Radiograph

    International Nuclear Information System (INIS)

    Lee, Sung Sik; Jang, Byoung Gyu; Kim, Young H.

    2002-01-01

    The computer simulation has been done for non-insulated and insulated pipes which are vacant or half filled with liquid. The simulation results showed that the density profile on the radiography is continuous and symmetrical around the center of pipe in the case of vacant pipe. On the other hand the density profiles are not symmetrical and depend on geometrical setting for radiography in the case of half filled pipes. Finally, experimental testing on a non-insulated carbon steel pipe with artificial notches of different depth is carried out using Ir-192 and industrial film. Comparing the measured density profile on the radiograph to the calculated one, it has been shown that it is possible to evaluate thickness variation by measuring density profile on a radiograph

  11. Radiation recommendation series: administratively required dental radiographs

    International Nuclear Information System (INIS)

    1981-09-01

    Administrative requirements for radiographs are found in many segments of the United States health care system. This document presents an FDA radiation recommendation on administratively required dental x-ray examinations. In general, such examinations are not requested to further the patient's dental health, but rather as a means of monitoring claims. However, the administrative use of radiographs that have been taken in the normal course of patient care is usually appropriate, as long as the patient's right to privacy is respected

  12. CT colonography training for radiographers - a formal evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Haycock, A. [Intestinal Imaging Centre and Wolfson Unit for Endoscopy, St Mark' s Hospital, Imperial College London, London (United Kingdom); Burling, D., E-mail: burlingdavid@yahoo.co.u [Intestinal Imaging Centre and Wolfson Unit for Endoscopy, St Mark' s Hospital, Imperial College London, London (United Kingdom); Wylie, P.; Muckian, J.; Ilangovan, R.; Thomas-Gibson, S. [Intestinal Imaging Centre and Wolfson Unit for Endoscopy, St Mark' s Hospital, Imperial College London, London (United Kingdom)

    2010-12-15

    Aims: To evaluate the efficacy of a new intensive 'hands-on' course designed to train small teams of radiographers in computed tomography colonography (CTC) technique and initial interpretation for patient triage. Materials and methods: The course comprised small-group lectures, active participation in the daily CTC service with practical technique and image interpretation training by experienced radiologists and radiographers. Evaluation was by assessment of knowledge using randomized sets of multiple choice questions (MCQ; pre/post-course), practical technique using checklists and expert global scores, and interpretation performance outcomes using randomized pre/post-course test datasets (five validated CTC examinations each). Paired t-tests were used to investigate change in performance for MCQ score and interpretation accuracy. Results: Thirteen courses with 49 participants were evaluated over 2 years. Practical skills were high, with mean (SD) checklist scores of 14/15 (0.85) and global scores of 26/30 (2.3). MCQ scores increased significantly from a mean of 59% pre-course to 69% post-course, p < 0.001. Correct classification of CTC examination improved significantly from a mean of 55% pre-course to 71% post-course, p < 0.001. Cancer and large polyp (>10 mm) detection rates also improved significantly from 49% to 60%, p = 0.002. Conclusion: Structured training in CTC can significantly improve knowledge and interpretation skills of radiographers, while assessing safe procedural performance. Implementation of similar programmes nationally may help reduce performance gaps between centres.

  13. CT colonography training for radiographers - a formal evaluation

    International Nuclear Information System (INIS)

    Haycock, A.; Burling, D.; Wylie, P.; Muckian, J.; Ilangovan, R.; Thomas-Gibson, S.

    2010-01-01

    Aims: To evaluate the efficacy of a new intensive 'hands-on' course designed to train small teams of radiographers in computed tomography colonography (CTC) technique and initial interpretation for patient triage. Materials and methods: The course comprised small-group lectures, active participation in the daily CTC service with practical technique and image interpretation training by experienced radiologists and radiographers. Evaluation was by assessment of knowledge using randomized sets of multiple choice questions (MCQ; pre/post-course), practical technique using checklists and expert global scores, and interpretation performance outcomes using randomized pre/post-course test datasets (five validated CTC examinations each). Paired t-tests were used to investigate change in performance for MCQ score and interpretation accuracy. Results: Thirteen courses with 49 participants were evaluated over 2 years. Practical skills were high, with mean (SD) checklist scores of 14/15 (0.85) and global scores of 26/30 (2.3). MCQ scores increased significantly from a mean of 59% pre-course to 69% post-course, p 10 mm) detection rates also improved significantly from 49% to 60%, p = 0.002. Conclusion: Structured training in CTC can significantly improve knowledge and interpretation skills of radiographers, while assessing safe procedural performance. Implementation of similar programmes nationally may help reduce performance gaps between centres.

  14. Consultant radiographer leadership - A discussion

    Energy Technology Data Exchange (ETDEWEB)

    Hogg, Peter [Directorate of Radiography, University of Salford, Allerton Building, Frederick Road, Salford, Greater Manchester M6 6PU (United Kingdom)], E-mail: p.hogg@salford.ac.uk; Hogg, Dianne [Henwood Associates (South East) Ltd, Company Number: 513796, Registered Office: 2 Lakeview Stables, Lower St Clere, Kemsing, Kent, TN15 6NL (United Kingdom); Henwood, Suzanne [East Lancashire Primary Care Trust, Linden Business Centre, Linden Road, Colne. BB8 9BA (United Kingdom)

    2008-12-15

    Effective leadership can be defined in many ways and is an essential element of successful organisations; poor leadership can result in problems such as low staff morale, high staff turnover and reduced productivity. Effective leadership behaviours are well documented in the literature and various leadership models have been proposed that illustrate these behaviours. This discussion paper does not focus on any particular model. Instead it considers the 'Leadership Qualities Framework' which was developed specifically for use within the UK National Health Service. This framework draws upon a range of leadership models and as such it gives a broad indication of leadership behaviours. The framework comprises three components - 'personal qualities', 'setting direction' and 'delivering the service'. This paper commences with an argument as to why effective leadership is important in organisations generally, and specifically within healthcare organisations. Various examples of leadership are illustrated from within and outside the NHS in order to demonstrate effective leadership behaviours. The Leadership Qualities Framework is then examined, along with scenarios to illustrate effective leadership behaviours in context (i.e. within a healthcare organisation). Subsequent reflections on the scenarios aim to identify leadership behaviours that are explained within the framework. The final element of this paper draws on [limited] published evidence of where consultant radiographers have demonstrated effective leadership behaviours. In this section the published evidence is examined and reflected upon. At the end of the article we indicate additional reading for those who wish to further develop their theoretical and practical leadership skills.

  15. Early characteristic radiographic changes in mucolipidosis II

    Energy Technology Data Exchange (ETDEWEB)

    Lai, Lillian M. [Lucile Packard Children' s Hospital and Stanford University, Pediatric Radiology, Palo Alto, CA (United States); Lachman, Ralph S. [Lucile Packard Children' s Hospital and Stanford University, Pediatric Radiology, Palo Alto, CA (United States); University of California, International Skeletal Dysplasia Registry, Los Angeles, CA (United States)

    2016-11-15

    Although mucolipidosis type II has similar metabolic abnormalities to those found in all the mucopolysaccharidoses and mucolipidoses, there are distinctive diagnostic radiographic changes of mucolipidosis II in the perinatal/newborn/infant period. To describe the early characteristic radiographic changes of mucolipidosis II and to document when these changes manifest and resolve. We retrospectively reviewed radiographs and clinical records of 19 cases of mucolipidosis II from the International Skeletal Dysplasia Registry (1971-present; fetal age to 21/2 years). A radiologist with special expertise in skeletal dysplasias evaluated the radiographs. The most common abnormalities were increased vertebral body height (80%, nonspecific), talocalcaneal stippling (86%), periosteal cloaking (74%) and vertebral body rounding (50%). Unreported findings included sacrococcygeal sclerosis (54%) and vertebral body sclerosis (13%). Rickets and hyperparathyroidism-like (pseudohyperparathyroidism) changes (rarely reported) were found in 33% of cases. These changes invariably started in the newborn period and resolved by 1 year of age. The conversion from these early infantile radiographic features to dysostosis multiplex changes occurred in 41% of cases, and within the first year after birth. Several findings strongly suggest the diagnosis of mucolipidosis II, including cloaking in combination with one or more of the following radiographic criteria: talocalcaneal stippling, sacrococcygeal or generalized vertebral body sclerosis, vertebral body rounding, or rickets/hyperparathyroidism-like changes in the perinatal/newborn/infancy period. These findings are not found in the other two forms of mucolipidosis nor in any of the mucopolysaccharidoses. (orig.)

  16. Early characteristic radiographic changes in mucolipidosis II

    International Nuclear Information System (INIS)

    Lai, Lillian M.; Lachman, Ralph S.

    2016-01-01

    Although mucolipidosis type II has similar metabolic abnormalities to those found in all the mucopolysaccharidoses and mucolipidoses, there are distinctive diagnostic radiographic changes of mucolipidosis II in the perinatal/newborn/infant period. To describe the early characteristic radiographic changes of mucolipidosis II and to document when these changes manifest and resolve. We retrospectively reviewed radiographs and clinical records of 19 cases of mucolipidosis II from the International Skeletal Dysplasia Registry (1971-present; fetal age to 21/2 years). A radiologist with special expertise in skeletal dysplasias evaluated the radiographs. The most common abnormalities were increased vertebral body height (80%, nonspecific), talocalcaneal stippling (86%), periosteal cloaking (74%) and vertebral body rounding (50%). Unreported findings included sacrococcygeal sclerosis (54%) and vertebral body sclerosis (13%). Rickets and hyperparathyroidism-like (pseudohyperparathyroidism) changes (rarely reported) were found in 33% of cases. These changes invariably started in the newborn period and resolved by 1 year of age. The conversion from these early infantile radiographic features to dysostosis multiplex changes occurred in 41% of cases, and within the first year after birth. Several findings strongly suggest the diagnosis of mucolipidosis II, including cloaking in combination with one or more of the following radiographic criteria: talocalcaneal stippling, sacrococcygeal or generalized vertebral body sclerosis, vertebral body rounding, or rickets/hyperparathyroidism-like changes in the perinatal/newborn/infancy period. These findings are not found in the other two forms of mucolipidosis nor in any of the mucopolysaccharidoses. (orig.)

  17. Radiographic manifestations of arthritis in AIDS patients

    International Nuclear Information System (INIS)

    Rosenberg, Z.S.; Norman, A.; Solomon, G.

    1988-01-01

    The purpose of this study is to familiarize the radiologist with a newly discovered association between arthritis and acquired immunodeficiency syndrome (AIDS). The authors retrospectively reviewed the clinical and radiographic findings in 31 patients with human immunodeficiency virus (HIV) infection referred to their rheumatology clinic with musculoskeletal complaints. The patients carried a wide range of clinical diagnosis including Reiter syndrome, psoriatic arthritis, undifferentiated seronegative arthritis, isolated enthesopathies, rheumatoid arthritis and osteonecrosis. Radiographs were available in 24 of the 31 patients, and in 20 they showed radiographic features of arthritis, which included soft-tissue swelling periarticular osteoporosis, synovial effusions, sacroiliitis, periosteal reaction, joint space narrowing, marginal erosions, and osteonecrosis. Although the radiographic abnormalities were frequently mild, they were significant, given the short duration of disease in many of their patients (weeks to months) at the time radiographs were obtained. The range of radiographic findings in their series was varied and paralleled the wide range of clinical diagnoses. No findings were pathognomonic for HIV-associated arthritis. Nevertheless, HIV infection needs to be considered in any patient belonging to a recognized risk group who presents with musculoskeletal disease. This is particularly important since immunosupressive drugs used for the treatment of arthritis can be detrimental to patients with HIV infection

  18. Radiographic signs and diagnosis of dental disease

    International Nuclear Information System (INIS)

    Bellows, J.

    1993-01-01

    Dental radiographs are critical for the complete assessment and treatment of dental diseases. Dental radiography is commonly used to evaluate congenital dental defects, periodontal disease, orthodontic manipulations, oral tumors, endodontic treatments, oral trauma, and any situation where an abnormality is suspected. Although standard radiographic equipment and film can be used to produce dental radiographs, dental X-ray equipment and film provide superior quality images and greater convenience of animal patient positioning. An understanding of normal dental radiographic anatomy is important when interpreting dental radiographs. Stage III periodontitis is the earliest stage of periodontal disease at which radiographic abnormalities become apparent. Bone loss associated with periodontal disease can be classified as either horizontal or vertical. Periapical radiolucencies can represent granulomas, cysts, or abscesses, whereas periapical radiodensities may represent sclerotic bone or condensing osteitis. Lytic lesions of the bone of the jaw often represent oral neoplasms. Neoplasms also can displace or disrupt teeth in the dental arch. Resorptive lesions can be external or internal and appear as radiolucent areas involving the external surface of the root or the pulp cavity, respectively. Feline dental resorptive lesions, also known as odontoclastic resorptions, are a specific form of dental resorptive lesions unique to cats

  19. Radiographer performed single contrast small bowel enteroclysis

    International Nuclear Information System (INIS)

    Law, Robert L.; Slack, Nicola; Harvey, Richard F.

    2005-01-01

    Aim: To analyse the technical success and reporting sensitivity of radiographer performed small bowel enteroclysis (SBE) undertaken by a specialist radiographer according to a standard technique [Nolan DJ, Cadman PJ. The small bowel enema made easy. Clinical Radiology 1987;38(3):295-301]. Methods: Patients (1413) had 1646 SBE in 10 years from May 1992 to April 2002. The original request card and the separate radiographer and consultant radiologist reports were reviewed. Where the radiology reports were discordant or inconclusive, the clinical notes were also reviewed. Results: Patients (1022) X-ray films were available. Nine hundred and forty-three (93.3%) SBEs had been successfully completed. Radiographer and consultant radiologist reporting had a 99.3% concordance. There was a 98.4% sensitivity for Crohn's disease (181 of 184 cases where Crohn's disease was the clinical final diagnosis). Overall reporting sensitivity was 93.7% although correct 'probably normal and abnormal' reporting bias suggests a sensitivity of 96.9%. Sixty of 943 (6.4%) reports were inconclusive. Of 1022 patients, 68 (6.6%) of small bowel intubations were not achieved, or else consent was withdrawn at the time of the procedure. Conclusion: Specialist radiographers can perform small bowel enteroclysis with a reporting sensitivity equal to that of a consultant radiologist. Radiographers accustomed to providing an SBE service become skilled at passing fine bore feeding tubes into the small bowel and can provide this service also

  20. Relativistic conformal magneto-hydrodynamics from holography

    International Nuclear Information System (INIS)

    Buchbinder, Evgeny I.; Buchel, Alex

    2009-01-01

    We use the AdS/CFT correspondence to study first-order relativistic viscous magneto-hydrodynamics of (2+1)-dimensional conformal magnetic fluids. It is shown that the first order magneto-hydrodynamics constructed following Landau and Lifshitz from the positivity of the entropy production is inconsistent. We propose additional contributions to the entropy motivated dissipative current and, correspondingly, new dissipative transport coefficients. We use the strongly coupled M2-brane plasma in external magnetic field to show that the new magneto-hydrodynamics leads to self-consistent results in the shear and sound wave channels.

  1. Dileptons from transport and hydrodynamical models

    International Nuclear Information System (INIS)

    Huovinen, P.; Koch, V.

    2000-01-01

    Transport and hydrodynamical models used to describe the expansion stage of a heavy-ion collision at the CERN SPS give different dilepton spectrum even if they are tuned to reproduce the observed hadron spectra. To understand the origin of this difference we compare the dilepton emission from transport and hydrodynamical models using similar initial states in both models. We find that the requirement of pion number conservation in a hydrodynamical model does not change the dilepton emission. Also the mass distribution from the transport model indicates faster cooling and longer lifetime of the fireball

  2. Tuning bacterial hydrodynamics with magnetic fields

    Science.gov (United States)

    Pierce, C. J.; Mumper, E.; Brown, E. E.; Brangham, J. T.; Lower, B. H.; Lower, S. K.; Yang, F. Y.; Sooryakumar, R.

    2017-06-01

    Magnetotactic bacteria are a group of motile prokaryotes that synthesize chains of lipid-bound, magnetic nanoparticles called magnetosomes. This study exploits their innate magnetism to investigate previously unexplored facets of bacterial hydrodynamics at surfaces. Through use of weak, uniform, external magnetic fields and local, micromagnetic surface patterns, the relative strength of hydrodynamic, magnetic, and flagellar force components is tuned through magnetic control of the bacteria's orientation. The resulting swimming behaviors provide a means to experimentally determine hydrodynamic parameters and offer a high degree of control over large numbers of living microscopic entities. The implications of this controlled motion for studies of bacterial motility near surfaces and for micro- and nanotechnology are discussed.

  3. Neutron radiographic techniques, facilities and applications

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1984-08-01

    This is a collection of three papers, written for presentation on two international conferences. The first paper: ''Neutron radiography. Techniques and facilities'', written by J.P. Barton of N-Ray Engineering Co. La Jolla, CA., USA and J.C. Domanus was presented at the International Symposium on the Use and Development of Low and Medium Flux Research Reactors at the Massachusets Institute of Technology, Cambridge, Mass., USA, 16-19 October 1983. The second paper: ''Neutron radiography with the DR-1 reactor at Risoe National Laboratory'', written by J.C. Domanus, was presented at the same Symposium. The third paper: ''Defects in nuclear fuel revealed by neutron radiography'', written by J.C. Domanus is accepted for presentation on 18 October 1984 to the 3rd European Conference on Nondestructive Testing, Florence, Italy, 15-18 October 1984. While the first paper describes the principles of neutron radiographic techniques and facilities, the second one describes an example of such facility and the third gives an example of application of neutron radiography in the field of nuclear fuel. (author)

  4. Relativistic hydrodynamic evolutions with black hole excision

    International Nuclear Information System (INIS)

    Duez, Matthew D.; Shapiro, Stuart L.; Yo, H.-J.

    2004-01-01

    We present a numerical code designed to study astrophysical phenomena involving dynamical spacetimes containing black holes in the presence of relativistic hydrodynamic matter. We present evolutions of the collapse of a fluid star from the onset of collapse to the settling of the resulting black hole to a final stationary state. In order to evolve stably after the black hole forms, we excise a region inside the hole before a singularity is encountered. This excision region is introduced after the appearance of an apparent horizon, but while a significant amount of matter remains outside the hole. We test our code by evolving accurately a vacuum Schwarzschild black hole, a relativistic Bondi accretion flow onto a black hole, Oppenheimer-Snyder dust collapse, and the collapse of nonrotating and rotating stars. These systems are tracked reliably for hundreds of M following excision, where M is the mass of the black hole. We perform these tests both in axisymmetry and in full 3+1 dimensions. We then apply our code to study the effect of the stellar spin parameter J/M 2 on the final outcome of gravitational collapse of rapidly rotating n=1 polytropes. We find that a black hole forms only if J/M 2 2 >1, the collapsing star forms a torus which fragments into nonaxisymmetric clumps, capable of generating appreciable 'splash' gravitational radiation

  5. Hydrodynamic study of an internal airlift reactor for microalgae culture.

    Science.gov (United States)

    Rengel, Ana; Zoughaib, Assaad; Dron, Dominique; Clodic, Denis

    2012-01-01

    Internal airlift reactors are closed systems considered today for microalgae cultivation. Several works have studied their hydrodynamics but based on important solid concentrations, not with biomass concentrations usually found in microalgae cultures. In this study, an internal airlift reactor has been built and tested in order to clarify the hydrodynamics of this system, based on microalgae typical concentrations. A model is proposed taking into account the variation of air bubble velocity according to volumetric air flow rate injected into the system. A relationship between riser and downcomer gas holdups is established, which varied slightly with solids concentrations. The repartition of solids along the reactor resulted to be homogenous for the range of concentrations and volumetric air flow rate studied here. Liquid velocities increase with volumetric air flow rate, and they vary slightly when solids are added to the system. Finally, liquid circulation time found in each section of the reactor is in concordance with those employed in microalgae culture.

  6. Conformal invariance in hydrodynamic turbulence

    International Nuclear Information System (INIS)

    Falkovich, Gregory

    2007-01-01

    This short survey is written by a physicist. It contains neither theorems nor precise definitions. Its main content is a description of the results of numerical solution of the equations of fluid mechanics in the regime of developed turbulence. Due to limitations of computers, the results are not very precise. Despite being neither exact nor rigorous, the findings may nevertheless be of interest for mathematicians. The main result is that the isolines of some scalar fields (vorticity, temperature) in two-dimensional turbulence belong to the class of conformally invariant curves called SLE (Scramm-Loewner evolution) curves. First, this enables one to predict and find a plethora of quantitative relations going far beyond what was known previously about turbulence. Second, it suggests relations between phenomena that seemed unrelated, like the Euler equation and critical percolation. Third, it shows that one is able to get exact analytic results in statistical hydrodynamics. In short, physicists have found something unexpected and hope that mathematicians can help to explain it.

  7. The hydrodynamics of swimming microorganisms

    International Nuclear Information System (INIS)

    Lauga, Eric; Powers, Thomas R

    2009-01-01

    Cell motility in viscous fluids is ubiquitous and affects many biological processes, including reproduction, infection and the marine life ecosystem. Here we review the biophysical and mechanical principles of locomotion at the small scales relevant to cell swimming, tens of micrometers and below. At this scale, inertia is unimportant and the Reynolds number is small. Our emphasis is on the simple physical picture and fundamental flow physics phenomena in this regime. We first give a brief overview of the mechanisms for swimming motility, and of the basic properties of flows at low Reynolds number, paying special attention to aspects most relevant for swimming such as resistance matrices for solid bodies, flow singularities and kinematic requirements for net translation. Then we review classical theoretical work on cell motility, in particular early calculations of swimming kinematics with prescribed stroke and the application of resistive force theory and slender-body theory to flagellar locomotion. After examining the physical means by which flagella are actuated, we outline areas of active research, including hydrodynamic interactions, biological locomotion in complex fluids, the design of small-scale artificial swimmers and the optimization of locomotion strategies.

  8. Pulsed high-energy radiographic machine emitting x-rays: PHERMEX

    International Nuclear Information System (INIS)

    Dick, R.D.

    1976-01-01

    The PHERMEX facility that is used to provide radiography of explosives and explosive-driven systems is described. This facility allows precision flash radiography of large objects containing high atomic number materials. The facility consists of a high-current, three-cavity, 27-MeV linear electron accelerator; a 13.5-MW radiofrequency power source; a timing, firing, and signal detection system; and a data acquisition system. PHERMEX was built in the early part of the 1960s to complement other hydrodynamics facilities at Los Alamos and to implement studies related to shock waves, detonation, and other hydrodynamic phenomena. After 15 y of operation and several thousand explosive shots later, PHERMEX has proven to be a very important diagnostic tool in the study of hydrodynamic systems. The attractive features of PHERMEX are the following: very intense submicrosecond 27-MeV bremsstrahlung radiation; 1-mm diam spot size; 100 R at 1 m from a 200-ns pulse; precise determination of edges, discontinuities, and areal mass distribution; and flash radiographs of large explosive systems close to the target

  9. Evaluation of underexposed conventional radiographs after digitization. Auswertung fehlbelichteter konventioneller Roentgenaufnahmen nach Digitalisierung

    Energy Technology Data Exchange (ETDEWEB)

    Wenz, W. (Freiburg Univ. (Germany). Abt. Roentgendiagnostik); Buitrago-Tellez, C. (Freiburg Univ. (Germany). Abt. Roentgendiagnostik); Moenig, H. (Freiburg Univ. (Germany). Inst. fuer Biophysik und Strahlenbiologie); Niemeier, R. (Digital Diagnostik Deutschland GmbH, Freiburg im Breisgau (Germany))

    1993-02-01

    Inadequate exposure of analogue radiographs is reported in the literature to occur in 5-25% of cases. Therefore, the present study was performed to test whether selective image processing after digitization could reveal diagnostic details on underexposed radiographs. In addition, the minimal exposure values required for diagnostic purposes after adequate image processing were studied. Phantom studies, organ preparations and measurements of physical parameters with decreasing exposure values were performed. The detection of anatomic and pathologic (nondisplaced fracture lines, microcalcification and renal stones) structures were evaluated by 12 readers. Radiographs with exposure values 20-40% lower than 'ideal' values can provide adequate diagnostic images after digital processing. The diagnostic information is significantly impaired with values under 50% of the correct exposure values. In conclusion, this method is adequate to save underexposed radiographs for diagnostic purposes and to avoid repeated examinations. (orig.)

  10. Clinical and radiographic evaluation of Portland cement added to radiopacifying agents in primary molar pulpotomies.

    Science.gov (United States)

    Lourenço Neto, N; Marques, N C T; Fernandes, A P; Hungaro Duarte, M A; Abdo, R C C; Machado, M A A M; Oliveira, T M

    2015-10-01

    This was to evaluate the clinical and radiographic outcomes of Portland cement (PC) added to radiopacifying agents in primary molar pulpotomies. Thirty primary mandibular molars of children aged between 5 and 9 years were randomly assigned to the following groups: PC; PC with iodoform (PC + CHI(3)); PC with zirconium oxide (PC + ZrO(2)) and treated by pulpotomy technique. Clinical and radiographic follow-up assessments were performed at 6, 12 and 24 months. Statistical analysis was performed by Fisher's exact test (P < 0.05). The clinical and radiographic evaluations showed 100 % success rates, and the results showed no statistically significant difference between groups. According to this study, PC added to radiopacifying agents exhibited satisfactory clinical and radiographic results in primary molar pulpotomies.

  11. Framing Camera Improvements and hydrodynamic Experiments

    National Research Council Canada - National Science Library

    Drake, R. P

    2007-01-01

    .... We also propose to participate in hydrodynamic experiments at NRL whenever they occur, to prepare for an experiment for NIKE to study the onset of turbulence via the Kelvin Helmholtz instability...

  12. Hydrodynamic limit of interacting particle systems

    International Nuclear Information System (INIS)

    Landim, C.

    2004-01-01

    We present in these notes two methods to derive the hydrodynamic equation of conservative interacting particle systems. The intention is to present the main ideas in the simplest possible context and refer for details and references. (author)

  13. Biomimetic shark skin: design, fabrication and hydrodynamic function.

    Science.gov (United States)

    Wen, Li; Weaver, James C; Lauder, George V

    2014-05-15

    Although the functional properties of shark skin have been of considerable interest to both biologists and engineers because of the complex hydrodynamic effects of surface roughness, no study to date has successfully fabricated a flexible biomimetic shark skin that allows detailed study of hydrodynamic function. We present the first study of the design, fabrication and hydrodynamic testing of a synthetic, flexible, shark skin membrane. A three-dimensional (3D) model of shark skin denticles was constructed using micro-CT imaging of the skin of the shortfin mako (Isurus oxyrinchus). Using 3D printing, thousands of rigid synthetic shark denticles were placed on flexible membranes in a controlled, linear-arrayed pattern. This flexible 3D printed shark skin model was then tested in water using a robotic flapping device that allowed us to either hold the models in a stationary position or move them dynamically at their self-propelled swimming speed. Compared with a smooth control model without denticles, the 3D printed shark skin showed increased swimming speed with reduced energy consumption under certain motion programs. For example, at a heave frequency of 1.5 Hz and an amplitude of ± 1 cm, swimming speed increased by 6.6% and the energy cost-of-transport was reduced by 5.9%. In addition, a leading-edge vortex with greater vorticity than the smooth control was generated by the 3D printed shark skin, which may explain the increased swimming speeds. The ability to fabricate synthetic biomimetic shark skin opens up a wide array of possible manipulations of surface roughness parameters, and the ability to examine the hydrodynamic consequences of diverse skin denticle shapes present in different shark species. © 2014. Published by The Company of Biologists Ltd.

  14. Radiographic and Clinical Analysis of Lateral Epicondylitis.

    Science.gov (United States)

    Shillito, Matthew; Soong, Maximillian; Martin, Nicholas

    2017-06-01

    The literature suggests that radiographs may be unnecessary in the initial evaluation of lateral epicondylitis because treatment is rarely altered as a result of the radiographic findings. The most commonly reported radiographic finding is calcification at the lateral epicondyle. Our goal was to perform a quantitative and qualitative analysis of this finding to determine its importance and possible relationship with various clinical factors and patient-reported measures. All patients diagnosed with lateral epicondylitis by a single surgeon during a 5-year period were retrospectively reviewed. Age, sex, laterality, hand dominance, pain visual analog scale, duration of symptoms, Quick-Disability of the Arm, Shoulder, and Hand questionnaire score, and history of steroid injection were recorded. Calcifications on standard elbow radiographs, acquired digitally and viewed at 200% magnification on a 24-inch monitor, were characterized by size and relationship with the lateral epicondyle. We reviewed 245 patients diagnosed with lateral epicondylitis. A total of 115 elbows (47%) demonstrated lateral epicondyle calcifications. Patients with and without calcifications were similar with regard to clinical factors, as were patients with larger or smaller lesions. Eighty-five elbows (35%) had additional radiographic findings. Treatment was not altered by the radiographic findings in any case. Lateral epicondyle calcifications are much more common in lateral epicondylitis than previously reported, possibly owing to modern digital radiography and magnification, although they do not appear to be related to clinical factors including patient-reported measures. Thus, patients and surgeons should be careful to avoid overinterpretation of such findings. Although radiographs may be helpful in ruling out additional pathology, we did not find other clinically important contributions to the initial evaluation and management of this condition, and thus we do not recommend their routine use

  15. Chest radiograph interpretation by medical students

    International Nuclear Information System (INIS)

    Jeffrey, D.R.; Goddard, P.R.; Callaway, M.P.; Greenwood, R.

    2003-01-01

    AIM: To assess the ability of final year medical students to interpret conventional chest radiographs. MATERIALS AND METHODS: Ten conventional chest radiographs were selected from a teaching hospital radiology department library that were good radiological examples of common conditions. All were conditions that a medical student should be expected to recognize by the end of their training. One normal radiograph was included. The radiographs were shown to 52 final year medical students who were asked to describe their findings. RESULTS: The median score achieved was 12.5 out of 20 (range 6-18). There was no difference between the median scores of male and female students (12.5 and 12.3, respectively, p=0.82) but male students were more likely to be certain of their answers than female students (median certainty scores 23.0 and 14.0, respectively). The overall degree of certainty was low. On no radiograph were more than 25% of students definite about their answer. Students had received little formal radiology teaching (2-42 h, median 21) and few expressed an interest in radiology as a career. Only two (3.8%) students thought they were good at interpreting chest radiographs, 17 (32.7%) thought they were bad or awful. CONCLUSION: Medical students reaching the end of their training do not perform well at interpreting simple chest radiographs. They lack confidence and have received little formal radiological tuition. Perhaps as a result, few are interested in radiology as a career, which is a matter for concern in view of the current shortage of radiologists in the UK

  16. Reliability of cervical lordosis measurement techniques on long-cassette radiographs.

    Science.gov (United States)

    Janusz, Piotr; Tyrakowski, Marcin; Yu, Hailong; Siemionow, Kris

    2016-11-01

    Lateral radiographs are commonly used to assess cervical sagittal alignment. Three assessment methods have been described and are commonly utilized in clinical practice. These methods are described for perfect lateral cervical radiographs, however in everyday practice radiograph quality varies. The aim of this study was to compare the reliability and reproducibility of 3 cervical lordosis (CL) measurement methods. Forty-four standing lateral radiographs were randomly chosen from a lateral long-cassette radiograph database. Measurements of CL were performed with: Cobb method C2-C7 (CM), C2-C7 posterior tangent method (PTM), sum of posterior tangent method for each segment (SPTM). Three independent orthopaedic surgeons measured CL using the three methods on 44 lateral radiographs. One researcher used the three methods to measured CL three times at 4-week time intervals. Agreement between the methods as well as their intra- and interobserver reliability were tested and quantified by intraclass correlation coefficient (ICC) and median error for a single measurement (SEM). ICC of 0.75 or more reflected an excellent agreement/reliability. The results were compared with repeated ANOVA test, with p  0.05). All three methods appeared to be highly reliable. Although, high agreement between all measurement methods was shown, we do not recommend using Cobb measurement method interchangeably with PTM or SPTM within a single study as this could lead to error, whereas, such a comparison between tangent methods can be considered.

  17. Appearance of the weight-bearing lateral radiograph in retrocalcaneal bursitis

    Science.gov (United States)

    Muller, Bart; Maas, Mario; Sierevelt, Inger N; van Dijk, C Niek

    2010-01-01

    Background and purpose A retrocalcaneal bursitis is caused by repetitive impingement of the bursa between the Achilles tendon and the posterosuperior calcaneus. The bursa is situated in the posteroinferior corner of Kager's triangle (retrocalcaneal recess), which is a radiolucency with sharp borders on the lateral radiograph of the ankle. If there is inflammation, the fluid-filled bursa is less radiolucent, making it difficult to delineate the retrocalcaneal recess. We assessed whether the radiographic appearance of the retrocalcaneal recess on plain digital (filmless) radiographs could be used in the diagnosis of a retrocalcaneal bursitis. Methods Whether or not there was obliteration of the retrocalcaneal recess (yes/no) on 74 digital weight-bearing lateral radiographs of the ankle was independently assessed by 2 observers. The radiographs were from 24 patients (25 heels) with retrocalcaneal bursitis (confirmed on endoscopic calcaneoplasty); the control group consisted of 50 patients (59 heels). Results The sensitivity of the test was 83% for observer 1 and 79% for observer 2. Specificity was 100% and 98%, respectively. The kappa value of the interobserver reliability test was 0.86. For observer 1, intraobserver reliability was 0.96 and for observer 2 it was 0.92. Interpretation On digital weight-bearing lateral radiographs of a retrocalcaneal bursitis, the retrocalcaneal recess has a typical appearance. PMID:20450438

  18. Accuracy of chest radiographs in the emergency diagnosis of heart failure

    Energy Technology Data Exchange (ETDEWEB)

    Studler, Ueli; Kretzschmar, Martin; Steinbrich, Wolfgang [University Hospital Basel, Department of Radiology, Basel (Switzerland); Christ, Michael; Breidthardt, Tobias; Noveanu, Markus; Perruchoud, Andre P.; Mueller, Christian [University Hospital Basel, Department of Internal Medicine, Basel (Switzerland); Schoetzau, Andreas [Institute of Biostatistics, Basel (Switzerland)

    2008-08-15

    The purpose of this study was to determine the diagnostic accuracy of chest radiographic findings of heart failure (HF) in current patients presenting with dyspnea in the emergency department. In a secondary analysis of the BASEL study, initial chest radiographs of 277 patients with acute dyspnea were evaluated by two radiologists blinded to the adjudicated diagnosis (56% had the final diagnosis of HF). Predefined radiographic criteria of HF were used. Statistical analysis included receiver-operating characteristic (ROC) analysis and calculation of a logistic regression model including B-type natriuretic peptide (BNP) levels. The reader's overall impression showed the highest area under the ROC curve for the diagnosis of HF in both supine and erect patient positions (0.855 and 0.857). Among individual radiographic findings, peribronchial cuffing in the supine position (0.829) showed the highest accuracies. The lowest accuracy was found for the vascular pedicle width in the supine position (0.461). Logistic regression analysis showed no significant differences between the reader's overall impression, the radiographic model, and BNP testing. In our study, the combination of radiographic features provided valuable information and was of comparable accuracy as BNP-testing for the diagnosis of HF. (orig.)

  19. Hydrodynamic approach to electronic transport in graphene

    Energy Technology Data Exchange (ETDEWEB)

    Narozhny, Boris N. [Institute for Theoretical Condensed Matter Physics, Karlsruhe Institute of Technology, Karlsruhe (Germany); National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), Moscow (Russian Federation); Gornyi, Igor V. [Institute for Theoretical Condensed Matter Physics, Karlsruhe Institute of Technology, Karlsruhe (Germany); Institute of Nanotechnology, Karlsruhe Institute of Technology, Karlsruhe (Germany); Ioffe Physical Technical Institute, St. Petersburg (Russian Federation); Mirlin, Alexander D. [Institute for Theoretical Condensed Matter Physics, Karlsruhe Institute of Technology, Karlsruhe (Germany); Institute of Nanotechnology, Karlsruhe Institute of Technology, Karlsruhe (Germany); Petersburg Nuclear Physics Institute, St. Petersburg (Russian Federation); Schmalian, Joerg [Institute for Theoretical Condensed Matter Physics, Karlsruhe Institute of Technology, Karlsruhe (Germany); Institute for Solid State Physics, Karlsruhe Institute of Technology, Karlsruhe (Germany)

    2017-11-15

    The last few years have seen an explosion of interest in hydrodynamic effects in interacting electron systems in ultra-pure materials. In this paper we briefly review the recent advances, both theoretical and experimental, in the hydrodynamic approach to electronic transport in graphene, focusing on viscous phenomena, Coulomb drag, non-local transport measurements, and possibilities for observing nonlinear effects. (copyright 2017 by WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  20. Improvements to SOIL: An Eulerian hydrodynamics code

    International Nuclear Information System (INIS)

    Davis, C.G.

    1988-04-01

    Possible improvements to SOIL, an Eulerian hydrodynamics code that can do coupled radiation diffusion and strength of materials, are presented in this report. Our research is based on the inspection of other Eulerian codes and theoretical reports on hydrodynamics. Several conclusions from the present study suggest that some improvements are in order, such as second-order advection, adaptive meshes, and speedup of the code by vectorization and/or multitasking. 29 refs., 2 figs

  1. Relabeling symmetries in hydrodynamics and magnetohydrodynamics

    International Nuclear Information System (INIS)

    Padhye, N.; Morrison, P.J.

    1996-04-01

    Lagrangian symmetries and concomitant generalized Bianchi identities associated with the relabeling of fluid elements are found for hydrodynamics and magnetohydrodynamics (MHD). In hydrodynamics relabeling results in Ertel's theorem of conservation of potential vorticity, while in MHD it yields the conservation of cross helicity. The symmetries of the reduction from Lagrangian (material) to Eulerian variables are used to construct the Casimir invariants of the Hamiltonian formalism

  2. Immunologic basis for adverse reactions to radiographic contrast media

    Energy Technology Data Exchange (ETDEWEB)

    Stejskal, V; Nilsson, R; Grepe, A [Astra Pharmaceuticals AB, Soedertaelje (Sweden). Lab. of Safety Assessment Stockholm Univ. (Sweden). Dept. of Genetic and Cellular Toxicology Stockholm Univ. (Sweden). Wallenberglaboratoriet Danderyds Sjukhus, Danderyd (Sweden). Radiologic Clinic

    1990-11-01

    The lymphocyte transformation test (LTT) was used to elucidate whether certain side effects induced by radiographic contrast media have an immunologic etiology. Groups studied were: 8 patients who had previously experienced adverse reactions in association with urography, 6 patients who underwent urography without notable side reactions, 17 occupationally exposed nurses, and 9 unexposed controls. The lymphocytes from 2 hypersensitive patients and from 11 nurses exhibited a positive proliferative response to amidotrizoate. Five nurses who had shown a positive response, had a previous history of hypersensitivity reactions when handling contrast media, whereas the remaining 6 were free of symptoms. Amidotrizoatespecific memory cells were absent in patients who underwent urography without signs of hypersensitivity and in 7/9 of unexposed control subjects. Lymphocytes from patients sensitive to amidotrizoate cross-reacted to structurally related ionic contrast media while nonionic contrast agents did not induce proliferation of the lymphocytes. Thus, ionic radiographic contrast agents have antigenic properties in man. Irradiated mixtures of radiographic contrast media and serum proteins were, in general, not effective in inducing an LTT response. (orig.).

  3. Computerized detection of lung nodules in digital chest radiographs

    International Nuclear Information System (INIS)

    Giger, M.L.; Doi, K.; MacMahon, H.

    1987-01-01

    Detection of cancerous lung nodules in chest radiographs is one of the more important tasks performed by a radiologist. In addition, the ''miss rate'' associated with the radiographic detection of lung nodules is approximately 30%. A computerized scheme that alerts the radiologist to possible locations of lung nodules should allow this number of false-negative diagnoses to be reduced. The authors are developing a computer-aided nodule detection scheme based on a difference image approach. They attempt to eliminate the camouflaging background structure of the normal lung anatomy by creating, from a single-projection chest image, two images: one in which the signal-to-noise ratio (SNR) of the nodule is maximized and another in which that SNR is suppressed while the processed background remains essentially the same. Thus, the difference between these two processed images should consist of the nodule superimposed on a relatively uniform background in which the detection task may be simplified. This difference image approach is fundamentally different from conventional subtraction techniques (e.g., temporal or dual-energy subtraction) in that the two images which are subtracted arise from the same single-projection chest radiograph. Once the difference image is obtained, thresholding is performed along with tests for circularity, size and growth in order to extract the nodules. It should be noted that once an original chest image is input to the computer the nodule detection process is totally automated

  4. Immunologic basis for adverse reactions to radiographic contrast media

    International Nuclear Information System (INIS)

    Stejskal, V.; Nilsson, R.; Grepe, A.; Stockholm Univ.; Stockholm Univ.; Danderyds Sjukhus, Danderyd

    1990-01-01

    The lymphocyte transformation test (LTT) was used to elucidate whether certain side effects induced by radiographic contrast media have an immunologic etiology. Groups studied were: 8 patients who had previously experienced adverse reactions in association with urography, 6 patients who underwent urography without notable side reactions, 17 occupationally exposed nurses, and 9 unexposed controls. The lymphocytes from 2 hypersensitive patients and from 11 nurses exhibited a positive proliferative response to amidotrizoate. Five nurses who had shown a positive response, had a previous history of hypersensitivity reactions when handling contrast media, whereas the remaining 6 were free of symptoms. Amidotrizoatespecific memory cells were absent in patients who underwent urography without signs of hypersensitivity and in 7/9 of unexposed control subjects. Lymphocytes from patients sensitive to amidotrizoate cross-reacted to structurally related ionic contrast media while nonionic contrast agents did not induce proliferation of the lymphocytes. Thus, ionic radiographic contrast agents have antigenic properties in man. Irradiated mixtures of radiographic contrast media and serum proteins were, in general, not effective in inducing an LTT response. (orig.)

  5. Radiographic Assessment of Dental Maturation in Children With Dental Agenesis.

    Science.gov (United States)

    Medina, Aida Carolina; Pozo, Rodrigo Del; de Cedres, Lucila Blanco

    Dental agenesis is the most common developmental anomaly in humans, frequently associated with disorders in dental development and maturation. The purpose of this study is to determine radiographic variations in dental maturation in a group of Venezuelan children with dental agenesis. 1,188 panoramic radiographs, from healthy patients ages 5 to 12 years old were studied for agenesis of permanent teeth. Dental maturation was assessed by relative eruption and dental age according to Nolla, comparing children affected with dental agenesis to a stratified control group selected from the same population, excluding children with premature loss of primary teeth in the left quadrants and unclear radiographs. Descriptive analysis, and differences between means and medians (Student t test, Kruskall-Wallis p=0.05) were performed. Medians for Nolla stages were similar between groups, with delay in tooth formation in the agenesis group for second molars (p<0.05) and maxillary lateral incisors and second premolars. Dental age was significantly underestimated for both groups, -0.89 (±0.78) for the control group and -1.20 (±0.95) for the study group. Tooth eruption was similar between groups. Dental age was significantly delayed in Venezuelan children with dental agenesis, with variable significance for tooth formation of studied teeth.

  6. Australian rural radiographers' perspectives on disclosure of their radiographic opinion to patients

    International Nuclear Information System (INIS)

    Squibb, Kathryn; Bull, Rosalind M.; Smith, Anthony; Dalton, Lisa

    2015-01-01

    The role of Australian rural radiographers in radiographic interpretation, communication and disclosure of their radiographic opinion with a specific focus on plain film radiography was examined in a two phase, exploratory interpretive study. Data were collected using questionnaires and interviews and analysed thematically. This reports one of the key themes identified in the thematic data analysis. ‘Disclosure of Radiographic Opinion to Patients’ comprises the three interrelated sub-themes Acting Ethically, Selective Disclosure and Filtered Truth. It is wholly concerned with the ways in which rural radiographers choose to disclose their radiographic opinion to patients. Without a clear picture of where they stand medico-legally, rural radiographers draw on experience and a strong ethical framework as the basis for these complex decisions. Rural radiographers frame their disclosures to patients in a manner that is governed by the diagnostic, therapeutic and emotional impact the information disclosed may have on the patient. Disclosure to patients was found to be selective, often diagnostically vague and ethically filtered

  7. An audit of hip radiographs performed for general practitioners

    International Nuclear Information System (INIS)

    Bhatt, Raj; Rajesh, Arumugam; Morgan, Bruno; Finlay, David

    2001-01-01

    AIM: We carried out a prospective study of the GP referrals for hip radiographs to find out the proportion of radiographs falling within the RCR guidelines and to ascertain the reasons for not following the guidelines. MATERIALS AND METHODS: One thousand two hundred and fifty six consecutive hip radiographs were performed for GPs over a 12-month period. Questionnaires were sent to GPs for 873 referrals during an audit period of 18 months Four hundred and fifty three questionnaires were returned with adequate information. The proportion of change in management between the patients falling within the guidelines and those outside the guidelines was compared using Fisher's Exact Test (SPSS Package Version 9) and the corresponding 95% confidence interval (CI) was calculated. RESULTS: Only 194 (43%) of the 453 referrals were within RCR guidelines and 259 (57%) were outside guidelines. In the group where RCR guidelines were followed, 60% were normal, 34% had degenerative changes and 6% other diagnoses. The radiological reports changed management in 44%. In the group where guidelines were not followed 76% were normal, 18% had degenerative changes and 6% other diagnoses. The radiological reports changed management in 37%. There was no evidence of difference in the change in management between these two groups. Twenty per cent of the radiographs showed abnormalities other than hip changes. Of these, only 17% were abnormalities other than degenerative changes and considered significant. CONCLUSIONS: This audit does not reveal why the majority of the requests fell outside guidelines. This may be due to lack of awareness amongst GPs about guidelines, patient pressure, medico-legal problems and the need for reassurance. However, the audit does not show any evidence that following guidelines would increase efficiency of referral. Bhatt R. et al. (2001)

  8. Radiographic estimation in seropositive and seronegative rheumatoid arthritis.

    Science.gov (United States)

    Sahatçiu-Meka, Vjollca; Rexhepi, Sylejman; Manxhuka-Kërliu, Suzana; Rexhepi, Mjellma

    2011-08-01

    Long since it have been suggested that a subpopulation of patients with rheumatoid arthritis, diagnosed with negative rheumatoid factor tests, represents a clinical entity quite distinct from that of seropositive rheumatoid arthritis (RA). Our aim was to establish a scientific comparative analysis between seronegative and seropositive rheumatoid arthritis, regarding some radiological and clinical parameters, applied for the first time on patients from Kosovo. Two hundred fifty patients with rheumatoid arthritis according to the American College of Rheumatology criteria were retrospectively studied by analysis the radiographic damage and clinical parameters of the disease, using a data base. All examinees were between 25-60 years of age (Xb=49.96, SD=10.37) with disease duration between 1-27 years (Xb = 6.41, SD=6.47). All patients underwent a standardised evaluation radiographs. Baseline standardised poster anterior radiographs of hands and feet and radiographs of other joints, depending on indications, were assessed. Erythrocyte sedimentation rate values correlated with the radiological damages and statistical difference was found for seronegative subset (r=0.24, p<0.01). Longer duration of the disease resulted in the increase of radiological changes in both subsets (r=0.66, p<0.01) seronegative, (r=0.49, p<0.01) seropositive. Anatomic changes of IInd and IIIrd level were nearly equally distributed in both subsets, 76 (60.8%) seronegative, 75 (60%) seropositive. Radiological damages are nearly equal in both subsets, elevate in relation to the duration of the disease and correlate with ESR values. Regarding the sero-status, differences within sex, with some exceptions, are not relevant. Although there are some definite quantitative and qualitative differences regarding sero-status, obviously there is a great deal of overlap between the two groups.

  9. Radiographic estimation in seropositive and seronegative rheumatoid arthritis

    Directory of Open Access Journals (Sweden)

    Vjollca Sahatçiu-Meka

    2011-08-01

    Full Text Available Long since it have been suggested that a subpopulation of patients with rheumatoid arthritis, diagnosed with negative rheumatoid factor tests, represents a clinical entity quite distinct from that of seropositive rheumatoid arthritis (RA. Our aim was to establish a scientific comparative analysis between seronegative and seropositive rheumatoid arthritis, regarding some radiological and clinical parameters, applied for the first time on patients from Kosovo. Two hundred fifty patients with rheumatoid arthritis according to the American College of Rheumatology criteria were retrospectively studied by analysis the radiographic damage and clinical parameters of the disease, using a data base. All examinees were between 25-60 years of age (Xb=49.96, SD=10.37 with disease duration between 1-27 years (Xb = 6.41, SD=6.47. All patients underwent a standardised evaluation radiographs. Baseline standardised poster anterior radiographs of hands and feet and radiographs of other joints, depending on indications, were assessed. Erythrocyte sedimentation rate values correlated with the radiological damages and statistical difference was found for seronegative subset (r=0.24, p<0.01. Longer duration of the disease resulted in the increase of radiological changes in both subsets (r=0.66, p<0.01 seronegative, (r=0.49, p<0.01 seropositive. Anatomic changes of IInd and IIIrd level were nearly equally distributed in both subsets, 76 (60.8% seronegative, 75 (60% seropositive. Radiological damages are nearly equal in both subsets, elevate in relation to the duration of the disease and correlate with ESR values. Regarding the sero-status, differences within sex, with some exceptions, are not relevant. Although there are some definite quantitative and qualitative differences regarding sero-status, obviously there is a great deal of overlap between the two groups.

  10. High-frame-rate digital radiographic videography

    Science.gov (United States)

    King, Nicholas S. P.; Cverna, Frank H.; Albright, Kevin L.; Jaramillo, Steven A.; Yates, George J.; McDonald, Thomas E.; Flynn, Michael J.; Tashman, Scott

    1994-10-01

    High speed x-ray imaging can be an important tool for observing internal processes in a wide range of applications. In this paper we describe preliminary implementation of a system having the eventual goal of observing the internal dynamics of bone and joint reactions during loading. Two Los Alamos National Laboratory (LANL) gated and image intensified camera systems were used to record images from an x-ray image convertor tube to demonstrate the potential of high frame-rate digital radiographic videography in the analysis of bone and joint dynamics of the human body. Preliminary experiments were done at LANL to test the systems. Initial high frame-rate imaging (from 500 to 1000 frames/s) of a swinging pendulum mounted to the face of an X-ray image convertor tube demonstrated high contrast response and baseline sensitivity. The systems were then evaluated at the Motion Analysis Laboratory of Henry Ford Health Systems Bone and Joint Center. Imaging of a 9 inch acrylic disk with embedded lead markers rotating at approximately 1000 RPM, demonstrated the system response to a high velocity/high contrast target. By gating the P-20 phosphor image from the X-ray image convertor with a second image intensifier (II) and using a 100 microsecond wide optical gate through the second II, enough prompt light decay from the x-ray image convertor phosphor had taken place to achieve reduction of most of the motion blurring. Measurement of the marker velocity was made by using video frames acquired at 500 frames/s. The data obtained from both experiments successfully demonstrated the feasibility of the technique. Several key areas for improvement are discussed along with salient test results and experiment details.

  11. Shock-hydrodynamics experiments on the Nova laser

    International Nuclear Information System (INIS)

    Miller, P.; Peyser, T.; Stry, P.; Budil, K.; Wojtowicz, D.; Burke, E.

    1995-08-01

    We have conducted shock-induced hydrodynamics experiments using the Nova laser at Lawrence Livermore National Laboratory. The laser provides a high-enthalpy source by depositing its energy (about 22 kJ) in a small gold cavity called a Hohlraum. The Hohlraum serves as a driver section, launching very strong (M ∼ 20) shocks into millimeter-scale cylindrical ''shock tubes.'' The flow is imaged radiographically by an electronic framing camera, using a laser-generated x-ray source. Several topics have been addressed with this configuration, including shock-induced mixing at density interfaces (seeded with a variety of perturbations); the development of high-speed, shaped-charge-like jets; the effects of geometry on the planarity of the generated shocks; and shock-shock interactions which develop in the flows. This paper describes the general configuration of our experiments, presents an overview of the high-speed jet work, discusses some of our findings, and compares our results with computer simulations

  12. An implicit Smooth Particle Hydrodynamic code

    Energy Technology Data Exchange (ETDEWEB)

    Knapp, Charles E. [Univ. of New Mexico, Albuquerque, NM (United States)

    2000-05-01

    An implicit version of the Smooth Particle Hydrodynamic (SPH) code SPHINX has been written and is working. In conjunction with the SPHINX code the new implicit code models fluids and solids under a wide range of conditions. SPH codes are Lagrangian, meshless and use particles to model the fluids and solids. The implicit code makes use of the Krylov iterative techniques for solving large linear-systems and a Newton-Raphson method for non-linear corrections. It uses numerical derivatives to construct the Jacobian matrix. It uses sparse techniques to save on memory storage and to reduce the amount of computation. It is believed that this is the first implicit SPH code to use Newton-Krylov techniques, and is also the first implicit SPH code to model solids. A description of SPH and the techniques used in the implicit code are presented. Then, the results of a number of tests cases are discussed, which include a shock tube problem, a Rayleigh-Taylor problem, a breaking dam problem, and a single jet of gas problem. The results are shown to be in very good agreement with analytic solutions, experimental results, and the explicit SPHINX code. In the case of the single jet of gas case it has been demonstrated that the implicit code can do a problem in much shorter time than the explicit code. The problem was, however, very unphysical, but it does demonstrate the potential of the implicit code. It is a first step toward a useful implicit SPH code.

  13. Ultrasonic Testing

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyeong Jun; Kuk, Jeong Han

    2002-02-15

    This book introduces ultrasonic testing, which tells of outline of ultrasonic testing, principle of ultrasonic testing, prosperities of ultrasonic waves, radiographic test and ultrasonic test, basic theory on ultrasonic testing, mode conversion, transmission and diffraction, ultrasonic flaw detection and probe, standard test piece and reference test piece, like KS(JIS) ASME and ASTM, classification and properties of ultrasonic testing, straight beam method, angle beam method, ASME SEC.V.Art.5 ASTMA 388 and KS B 0817 Korean industrial standard.

  14. Radiographic study on temporomandibular joint Arthrosis

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Dong Soo [Dept. of Radiology, College of Dentistry, Seoul National University , Seoul (Korea, Republic of)

    1980-11-15

    The author analysed the routine radiographic changes and clinical symptoms of 205 cases of temporomandibular joint arthrosis. The clinical symptoms of the patients were classified and the morphological changes of condylar head, articular eminence, and articular fossa were analyzed and discussed from radiographic view point. The positional change of condylar head and articular fossa relation in TMJ arthrosis were observed. The frequencies of coincidence between the site of complaints and the site of the abnormal images which could be detected were examined. The results were obtained as follows; 1. Bone erosion, deformity, marginal proliferation and sclerosis were selected from many abnormal images as the radiographic diagnostic criteria of TMJ arthritic lesions. 2. Abnormal radiographic findings were revealed in 150 cases (73.9%) of 205 total TMJ arthrosis cases and site with abnormal findings coincided with the site of complaints in 105 cases (70.7%) of 150 cases and coincidence rates were higher above fourth decades than below third decades. 3. Sclerosis of the abnormal radiographic findings could be found more often below third decades than above fourth decades. 4. The positional changes of condylar head were revealed in 176 cases (85.9%) of 205 total cases. 5. Pain complaints were revealed in 170 cases(82.9%) and clicking sounds were revealed in 120 cases (58.6%) of clinical symptoms of TMJ arthrosis. 6. No tendency was found so far the differential diagnosis between pain dysfunction syndrome and osteoarthrosis of TMJ.

  15. Radiographic study on temporomandibular joint Arthrosis

    International Nuclear Information System (INIS)

    Yoo, Dong Soo

    1980-01-01

    The author analysed the routine radiographic changes and clinical symptoms of 205 cases of temporomandibular joint arthrosis. The clinical symptoms of the patients were classified and the morphological changes of condylar head, articular eminence, and articular fossa were analyzed and discussed from radiographic view point. The positional change of condylar head and articular fossa relation in TMJ arthrosis were observed. The frequencies of coincidence between the site of complaints and the site of the abnormal images which could be detected were examined. The results were obtained as follows; 1. Bone erosion, deformity, marginal proliferation and sclerosis were selected from many abnormal images as the radiographic diagnostic criteria of TMJ arthritic lesions. 2. Abnormal radiographic findings were revealed in 150 cases (73.9%) of 205 total TMJ arthrosis cases and site with abnormal findings coincided with the site of complaints in 105 cases (70.7%) of 150 cases and coincidence rates were higher above fourth decades than below third decades. 3. Sclerosis of the abnormal radiographic findings could be found more often below third decades than above fourth decades. 4. The positional changes of condylar head were revealed in 176 cases (85.9%) of 205 total cases. 5. Pain complaints were revealed in 170 cases(82.9%) and clicking sounds were revealed in 120 cases (58.6%) of clinical symptoms of TMJ arthrosis. 6. No tendency was found so far the differential diagnosis between pain dysfunction syndrome and osteoarthrosis of TMJ.

  16. Radiographers' preconditions for evidence-based radiography

    International Nuclear Information System (INIS)

    Ahonen, Sanna-Mari; Liikanen, Eeva

    2010-01-01

    Evidence-based practice (EBP) is essential in today's health care, but its establishment requires several preconditions from individuals and organizations (e.g. knowledge, understanding, attitudes, abilities, self-confidence, support, and resources). Previous studies suggest that radiographers do generate and use evidence in their work, but evidence-based radiography (EBR) is not yet used routinely as established practice, especially in terms of research utilization. This paper aims to describe radiographers' preconditions for EBR, and their participation in research activities. Main focus is on research utilization. Using an electronic questionnaire developed for this study, a survey was conducted: data collected from Finnish radiographers and radiotherapists (N = 438) were analysed both statistically and qualitatively. The final response rate was 39%. The results suggest radiographers' preconditions for EBR to consist of knowledge of research, significance of research activities, research-orientated way of working, and support. In addition, adequate resourcing is essential. Reading scientific journals, participation in research activities, a higher degree of education, and senior post seem to be significant promoters of EBR and research utilization. The results support the notion that EBR, and especially research utilization, are not yet well-established in Finland, and radiographers' viewpoints concerning the role and significance of research evidence and research activities still seem to vary.

  17. Radiographic evaluation of the diabetic foot

    International Nuclear Information System (INIS)

    Jacobs, A.M.

    1989-01-01

    Radiographic evaluation of the foot in the patient with diabetes mellitus is discussed in this paper. According to the author, it can only be of value when the soft tissue and bony and joint pathologic conditions, which occur more frequently in the diabetic patient are also considered and understood. Although not pathognomic for diabetes mellitus, neuroarthopathy, osteomyelitis, soft tissue infection, and some rheumatic disorders are present with greater frequency in diabetic populations than in non-diabetic populations. Frequently, edema, erythema, hyperthermia, and tenderness are present as nonspecific clinical findings, in which case radiographic evaluation is called upon to define the specific etiology of a particular patient's pathology. Unfortunately, many radiographic, computerized tomographic, and radionuclide studies demonstrate less than optimal positive and negative predictive values unless interpreted in view of clinical history and examination and integrated with the results of other laboratory data. Radiographic evaluation of the diabetic foot may be utilized to establish the presence of disease, the extent of pedal involvement, and the response to therapy. The establishment of the nature of disease processes from radiographic findings alone, however, may be problematic. The diagnosis of osteomyelitis, for example, rests on the recovery of the offending microorganisms from bone aspiration or culture

  18. Hydrodynamics of soft active matter

    Science.gov (United States)

    Marchetti, M. C.; Joanny, J. F.; Ramaswamy, S.; Liverpool, T. B.; Prost, J.; Rao, Madan; Simha, R. Aditi

    2013-07-01

    This review summarizes theoretical progress in the field of active matter, placing it in the context of recent experiments. This approach offers a unified framework for the mechanical and statistical properties of living matter: biofilaments and molecular motors in vitro or in vivo, collections of motile microorganisms, animal flocks, and chemical or mechanical imitations. A major goal of this review is to integrate several approaches proposed in the literature, from semimicroscopic to phenomenological. In particular, first considered are “dry” systems, defined as those where momentum is not conserved due to friction with a substrate or an embedding porous medium. The differences and similarities between two types of orientationally ordered states, the nematic and the polar, are clarified. Next, the active hydrodynamics of suspensions or “wet” systems is discussed and the relation with and difference from the dry case, as well as various large-scale instabilities of these nonequilibrium states of matter, are highlighted. Further highlighted are various large-scale instabilities of these nonequilibrium states of matter. Various semimicroscopic derivations of the continuum theory are discussed and connected, highlighting the unifying and generic nature of the continuum model. Throughout the review, the experimental relevance of these theories for describing bacterial swarms and suspensions, the cytoskeleton of living cells, and vibrated granular material is discussed. Promising extensions toward greater realism in specific contexts from cell biology to animal behavior are suggested, and remarks are given on some exotic active-matter analogs. Last, the outlook for a quantitative understanding of active matter, through the interplay of detailed theory with controlled experiments on simplified systems, with living or artificial constituents, is summarized.

  19. Relativistic hydrodynamics in the presence of puncture black holes

    International Nuclear Information System (INIS)

    Faber, Joshua A.; Etienne, Zachariah B.; Shapiro, Stuart L.; Taniguchi, Keisuke; Baumgarte, Thomas W.

    2007-01-01

    Many of the recent numerical simulations of binary black holes in vacuum adopt the moving puncture approach. This successful approach avoids the need to impose numerical excision of the black hole interior and is easy to implement. Here we wish to explore how well the same approach can be applied to moving black hole punctures in the presence of relativistic hydrodynamic matter. First, we evolve single black hole punctures in vacuum to calibrate our Baumgarte-Shapiro-Shibata-Nakamura implementation and to confirm that the numerical solution for the exterior spacetime is invariant to any junk (i.e., constraint-violating) initial data employed in the black hole interior. Then we focus on relativistic Bondi accretion onto a moving puncture Schwarzschild black hole as a numerical test bed for our high-resolution shock-capturing relativistic hydrodynamics scheme. We find that the hydrodynamical equations can be evolved successfully in the interior without imposing numerical excision. These results help motivate the adoption of the moving puncture approach to treat the binary black hole-neutron star problem using conformal thin-sandwich initial data

  20. Radiographic findings in tuberculosis of the calvarium

    Energy Technology Data Exchange (ETDEWEB)

    Patankar, T.; Varma, R.; Krishnan, A.; Prasad, S. [Dept. of Radiology, King Edward Memorial Hospital, Parel, Bombay (India); Desai, K. [Dept. of Neurosurgery, King Edward Memorial Hospital, Bombay (India); Castillo, M. [Dept. of Radiology, University of North Carolina School of Medicine, Chapel Hill, NC (United States)

    2000-07-01

    We reviewed the pattern of involvement of the calvarium by tuberculosis (TB) in five patients and the role of imaging in its management. Four patients presented with localised scalp swelling and one with generalized seizures. Radiographs revealed lucent lesions with minimal surrounding sclerosis in the frontal (2), parietal (2) and occipital (1) bones. CT showed lesions involving the entire thickness of the calvarium and accompanying contrast-enhancing soft tissue. The patient presenting with seizures had a ring-enhancing lesion in the parietal lobe in addition to the extra-axial lesions. Although radiographs in all cases demonstrated calvarial TB, CT showed the extent of the defect, involvement of adjacent soft tissues, and in one case an intra-axial lesion. Radiographs suffice for follow-up of these patients. (orig.)

  1. Understanding chest radiographic anatomy with MDCT reformations

    Energy Technology Data Exchange (ETDEWEB)

    Sussmann, A.R. [Department of Radiology, Thoracic Imaging, NYU Langone Medical Center, New York, NY (United States); Ko, J.P., E-mail: jane.ko@nyumc.or [Department of Radiology, Thoracic Imaging, NYU Langone Medical Center, New York, NY (United States)

    2010-02-15

    Chest radiograph interpretation requires an understanding of the mediastinal reflections and anatomical structures. Computed tomography (CT) improves the learning of three-dimensional (3D) anatomy, and more recently multidetector CT (MDCT) technology has enabled the creation of high-quality reformations in varying projections. Multiplanar reformations (MPRs) of varying thickness in the coronal and sagittal projections can be created for direct correlation with findings on frontal and lateral chest radiographs, respectively. MPRs enable simultaneous visualization of the craniocaudal extent of thoracic structures while providing the anatomic detail that has been previously illustrated using cadaveric specimens. Emphasis will be placed on improving knowledge of mediastinal anatomy and reflections including edges, lines, and stripes that are visible on chest radiographs.

  2. Radiographic abnormalities in tricyclic acid overdose

    International Nuclear Information System (INIS)

    Varnell, R.M.; Richardson, M.L.; Vincent, J.M.; Godwin, J.D.

    1987-01-01

    Several case reports have described adult respiratory distress syndrome (ARDS) secondary to tricyclic acid (TCA) overdose. During a 1-year period 83 patients requiring intubation secondary to drug overdose were evaluated. Abnormalities on chest radiographs occurred in 26 (50%) of the 54 patients with TCA overdose, compared to six (21%) of the 29 patients overdosed with other drugs. In addition, five (9%) of the patients with TCA overdose subsequently had radiographic and clinical abnormalities meeting the criteria for ARDS. Only one (3%) of the patients with non-TCA overdose subsequently had change suggesting ARDS. TCAs should be added to the list of drugs associated with ARDS, and TCA overdose should be considered a major risk factor in the development of radiographically evident abnormalities

  3. Opportunistic esophagitis in AIDS: Radiographic diagnosis

    International Nuclear Information System (INIS)

    Levine, M.S.; Woldenberg, R.; Herlinger, H.; Laufer, I.

    1987-01-01

    Between 1983 and 1986, 35 of 90 patients with acquired immunodeficiency syndrome (AIDS) had double-contrast esophagograms to rule out opportunistic esophagitis. The radiographs were reviewed without knowledge of the clinical or endoscopic findings. Candida esophagitis was diagnosed radiographically in 17 patients who had varying degrees of plaque formation and viral esophagitis in three who had discrete ulcers without plaques. All three patients with viral esophagitis (herpes in 2 and cytomegalo virus in one) and 15 of 17 with Candida esophagitis had endoscopic and/or clinical corroboration of the radiographic diagnosis. Thus, the authors' experience suggests that fungal and viral esophagitis can often be differentiated on double-contrast esophagography, so that appropriate antifungal or antiviral therapy can be instituted without need for endoscopic intervention

  4. Initial image interpretation of appendicular skeletal radiographs: A comparison between nurses and radiographers

    International Nuclear Information System (INIS)

    Piper, Keith J.; Paterson, Audrey

    2009-01-01

    Purpose: To examine the effect of a short training programme on nurses and radiographers, exploring differences between their performance before and after training. Method: Twenty-two nurses and 18 radiographers interpreted 20 trauma radiographs of the appendicular skeleton before and after training. Normal and abnormal cases of a discriminatory nature were included. Total score, sensitivity and specificity values were calculated for each participant by comparison with an agreed expected answer. The area under the curve (AUC) was analysed using alternate free-response receiver operating characteristic (AFROC) methodology. Results: Significant differences were demonstrated between the total scores achieved by the two groups (pre-training: p = 0.007, post-training: p = 0.04). After training, the mean score increased significantly for both groups (p < 0.001). No significant difference was found between the radiographers mean pre-training scores and the nurses mean post-training scores (p = 0.66). Sensitivity for both groups increased following training, significantly so for the nurses (nurses: p < 0.001, radiographers: p = 0.06). Specificity reduced significantly after training for the nurses (p < 0.001), and increased for the radiographers but not significantly (p = 0.085). After training, there was no significant difference between the two groups in terms of sensitivity (p = 0.09) but specificity was significantly higher for the radiographers (p < 0.001). The radiographers achieved higher pre-training AUC values than the nurses (p = 0.04), although a difference remained after training this did not achieve statistical significance (p = 0.15). The AUC values increased significantly after training for both groups (nurses: p = 0.012, radiographers: p = 0.004) and again there was no significant difference between the radiographers pre-training performance and the nurses post-training performance (p = 0.62). Conclusion: Improvement after training was seen in both groups

  5. Radiographic indices for lumbar developmental spinal stenosis

    Directory of Open Access Journals (Sweden)

    Jason Pui Yin Cheung

    2017-02-01

    Full Text Available Abstract Background Patients with developmental spinal stenosis (DSS are susceptible to developing symptomatic stenosis due to pre-existing narrowed spinal canals. DSS has been previously defined by MRI via the axial anteroposterior (AP bony spinal canal diameter. However, MRI is hardly a cost-efficient tool for screening patients. X-rays are superior due to its availability and cost, but currently, there is no definition of DSS based on plain radiographs. Thus, the aim of this study is to develop radiographic indices for diagnosing DSS. Methods This was a prospective cohort of 148 subjects consisting of patients undergoing surgery for lumbar spinal stenosis (patient group and asymptomatic subjects recruited openly from the general population (control group. Ethics approval was obtained from the local institutional review board. All subjects underwent MRI for diagnosing DSS and radiographs for measuring parameters used for creating the indices. All measurements were performed by two independent investigators, blinded to patient details. Intra- and interobserver reliability analyses were conducted, and only parameters with near perfect intraclass correlation underwent receiver operating characteristic (ROC analysis to determine the cutoff values for diagnosing DSS using radiographs. Results Imaging parameters from a total of 66 subjects from the patient group and 82 asymptomatic subjects in the control group were used for analysis. ROC analysis suggested sagittal vertebral body width to pedicle width ratio (SBW:PW as having the strongest sensitivity and specificity for diagnosing DSS. Cutoff indices for SBW:PW were level-specific: L1 (2.0, L2 (2.0, L3 (2.2, L4 (2.2, L5 (2.5, and S1 (2.8. Conclusions This is the first study to define DSS on plain radiographs based on comparisons between a clinically relevant patient group and a control group. Individuals with DSS can be identified by a simple radiograph using a screening tool allowing for better

  6. Optimizing radiation exposure for CT localizer radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Bohrer, Evelyn; Maeder, Ulf; Fiebich, Martin [Univ. of Applied Sciences, Giessen (Germany). Inst. of Medical Physics and Radiation Protection-IMPS; Schaefer, Stefan; Krombach, Gabriele A. [Univ. Hospital Giessen (Germany). Dept. of Radiology; Noel, Peter B. [Technische Univ. Muenchen (Germany). Dept. of Diagnostic and Interventional Radiology

    2017-08-01

    The trend towards submillisievert CT scans leads to a higher dose fraction of localizer radiographs in CT examinations. The already existing technical capabilities make dose optimization of localizer radiographs worthwhile. Modern CT scanners apply automatic exposure control (AEC) based on attenuation data in such a localizer. Therefore not only this aspect but also the detectability of anatomical landmarks in the localizer for the desired CT scan range adjustment needs to be considered. The effective dose of a head, chest, and abdomen-pelvis localizer radiograph with standard factory settings and user-optimized settings was determined using Monte Carlo simulations. CT examinations of an anthropomorphic phantom were performed using multiple sets of acquisition parameters for the localizer radiograph and the AEC for the subsequent helical CT scan. Anatomical landmarks were defined to assess the image quality of the localizer. CTDI{sub vol} and effective mAs per slice of the helical CT scan were recorded to examine the impact of localizer settings on a helical CT scan. The dose of the localizer radiograph could be decreased by more than 90% while the image quality remained sufficient when selecting the lowest available settings (80 kVp, 20 mA, pa tube position). The tube position during localizer acquisition had a greater impact on the AEC than the reduction of tube voltage and tube current. Except for the use of a pa tube position, all changes of acquisition parameters for the localizer resulted in a decreased total radiation exposure. A dose reduction of CT localizer radiograph is necessary and possible. In the examined CT system there was no negative impact on the modulated helical CT scan when the lowest tube voltage and tube current were used for the localizer.

  7. Comparison of tentative radiographic working length with and without grid versus electronic apex locator

    Directory of Open Access Journals (Sweden)

    Tanikonda Rambabu

    2018-01-01

    Full Text Available The apical termination of obturation is the most important factor influencing the success of root canal treatment (RCT. Working length (WL is the key element in achieving this. Aim: The aim of this study is to compare and evaluate the preoperative estimated WL with conventional radiograph and with grid radiograph, with reference to electronic apex locator (EAL in single-rooted teeth. Settings and Design: Thirty permanent anterior teeth with complete root formation indicated for RCT were included in this study. Materials and Methods: Conventional radiograph (Group 1 and conventional radiograph with external grid (Group 2 were made before access opening. WL with EAL (Group 3 was determined after access opening. Statistical Analysis: The statistical package for the social sciences (SPSS version 16.0 (SPSS Inc., Chicago, IL, USA was used to compare the WLs of three groups, and the statistical significance was considered to be P ≤ 0.05. ANOVA, post hoc test were made to measure the intergroup comparison, and Pearson correlation values were obtained. Results and Conclusion: The results of the study showed a higher correlation between grid WL and apex locator WL than conventional WL and apex locator WL. Preoperative metrics with radiographic grid along with the apex locator is a better measuring tool compared to the conventional radiographic WL in a single-rooted tooth.

  8. Agreement Between Panoramic and Lateral Cephalometric Radiographs for Measuring the Gonial Angle

    International Nuclear Information System (INIS)

    Zangouei-Booshehri, Maryam; Aghili, Hossein-Agha; Abasi, Mojtaba; Ezoddini-Ardakani, Fatemeh

    2012-01-01

    The gonial angle is one of the most important measurements required for orthodontic treatment and orthognathic surgery. It is difficult to determine the accurate measurement of each gonial angle on cephalometric radiographs because of superimposition of the left and right angles. The aim of the present study was to determine the right and left gonial angles on panoramic radiographs and to compare them with an evaluated cephalometric sample. A total of 80 panoramic and 80 cephalometric radiographs were obtained from 6 to 12-year-old children and the gonial angle was determined by the tangent of the inferior border of the mandible and the most distal aspect of the ascending ramus and the condyleon both panoramic and cephalometric radiographs. We used Pearson’s correlation coefficient and paired t-test for comparison. The mean gonial angle was 127.07 ± 6.10 and 127.5 ± 6.67 degrees on panoramic and cephalometric radiographs, respectively. There was no statistically significant difference between the measured gonial angles on panoramic and cephalometric radiographs and also no difference between the right and left (both Ps = 0.18) The value of the gonial angle measured on panoramic radiography was the same as that measured on the routinely used cephalometric radiography

  9. Effectiveness Of Plain Shoulder Radiograph In Detecting Degenerate Rotator Cuff Tears.

    Science.gov (United States)

    Hussain, Adnan; Muzzammil, Muhammad; Butt, Faisal; Valsamis, Epaminondas Markos; Dwyer, Amitabh J

    2018-01-01

    Studies have demonstrated radiographic findings of sclerosis and cortical irregularity at the greater tuberosity can suggest a rotator cuff tear. Plain radiographs are the most easily attainable first-line investigations in evaluating shoulder injuries. This study determines the effectiveness in predicting degenerate rotator cuff tears by detecting radiographic changes on shoulder x-rays. Retrospective cross-sectional study with a consecutive series of patients conducted in Hinchingbrooke Hospital, Huntingdon, United Kingdom from January 2015 to June 2017. Anteroposterior shoulder radiographs of 150 symptomatic patients who underwent shoulder arthroscopy were independently analysed by surgeons who were blinded from the arthroscopic results. Patients aged fewer than 30 and over 70 years were excluded. Patients with advanced osteoarthritis and cuff tear arthropathy evident on x-rays were also excluded. Sixty-five patients included in the study had rotator cuff tears on arthroscopy. Radiographic changes were correlated with arthroscopic findings to determine this test's ability to predict degenerate rotator cuff tears. When both cortical irregularity and sclerosis were present on the plain radiograph, these signs had a sensitivity of 78.8% [95% CI 65.7, 87.8%] and specificity 77.4% [95% CI 67.2, 85.0%] with a positive predictive value of 68.3%, using contingency table analysis. The presence of cortical irregularity was found to be a better predictor of a tear as compared to sclerosis. This study concludes that plain radiograph are good modality for initial evaluation of rotator cuff tears and detecting when both cortical irregularity and sclerosis. Consideration of these radiographic findings serves as a useful adjunct in diagnostic workup and can guide subsequent investigations and treatment when evaluating rotator cuff tears of the shoulder.

  10. Chest radiographic staging in allergic bronchopulmonary aspergillosis: relationship with immunological findings.

    LENUS (Irish Health Repository)

    Kiely, J L

    2012-02-03

    The question of whether a chest radiographic severity staging system could be correlated with standard blood\\/serum diagnostic indices in allergic bronchopulmonary aspergillosis (ABPA) was addressed in 41 patients. Asthma and positive Aspergillus fumigatus (AF) serology were considered essential diagnostic inclusion criteria. Eosinophil count, serum immunoglobulin (Ig)E and immediate skin hypersensitivity were also tested to grade patients as "definite" or "likely" ABPA. Definite cases had all five of these factors present, whereas likely cases had three or more. Chest radiographs were examined by experienced radiologists blinded to the clinical data. The six-stage radiographic score (0-5) was based on the severity and duration of changes seen: stage 0: normal; stage 1: transient hyperinflation; stage 2: transient minor changes; stage 3: transient major changes; stage 4: permanent minor changes; and stage 5: permanent major changes. Significant positive correlations (p<0.05) were observed between peak AF titres (expressed as an index), peak eosinophil count and radiographic severity stage. When considered as subgroups, these correlations approached, but did not reach, significance for the group with "likely" ABPA (n=28), but in the group with definite ABPA (n=13), there was a high correlation between radiographic score and peak AF index (r=0.59), as well as peak eosinophil count (r=0.62). This study suggests that the peak Aspergillus fumigatus index and eosinophil counts correlate best with the severity of radiographic stages in allergic bronchopulmonary aspergillosis. This chest radiographic staging system may be useful in the clinical assessment and management of patients with allergic bronchopulmonary aspergillosis, particularly in those patients with more severe radiographic stages.

  11. Radiographic Assessment for Back Pain

    Science.gov (United States)

    ... Nerve Tests: EMG, NCV and SEEP Alternative Medicine Acupuncture Herbal Supplements Surgical Options Anterior Cervical Fusion Artifical ... are a student athlete, if you have a history of osteoporosis, if you have a history of ...

  12. Pseudoprominent aorta: Radiographic findings and CT correlation

    International Nuclear Information System (INIS)

    Brown, K.T.; Shepard, J.A.O.; Stewart, W.J.

    1985-01-01

    The presence of a persistent left-sided superior vena cava (LSVC) in the absence of a right-sided superior vena cava (RSVC) may be suspected on a posteroanterior (PA) chest radiograph because of a prominent-appearing ascending aorta, which results from the absence of the RSVC. In the absence of an RSVC, the right upper lobe abuts and outlines the course of the ascending aorta, allowing better demonstration of its profile. This report describes a patient with this finding on a PA chest radiograph. Computed tomographic correlation is presented

  13. Inferior hilar window on lateral chest radiographs

    International Nuclear Information System (INIS)

    Park, C.K.; Webb, W.R.; Klein, J.S.

    1990-01-01

    This paper determines the accuracy of lateral chest radiography in the detection of masses in the inferior hilar window, a normally avascular hilar region anterior to the lower lobe bronchi. Fifty patients with normal thoracic CT scans and 25 with hilar masses/adenopathy were selected retrospectively. The 75 corresponding lateral chest radiographs were blindly evaluated for visibility of the anterior walls of the lower lobe bronchi and the presence and laterality of abnormal soft tissue (>1 cm) in the inferior hilar window. Only a 7 x 7-cm square of the lateral radiograph was viewed

  14. Pelvic radiograph in skeletal dysplasias: An approach

    Directory of Open Access Journals (Sweden)

    Manisha Jana

    2017-01-01

    Full Text Available The bony pelvis is constituted by the ilium, ischium, pubis, and sacrum. The pelvic radiograph is an important component of the skeletal survey performed in suspected skeletal dysplasia. Most of the common skeletal dysplasias have either minor or major radiological abnormalities; hence, knowledge of the normal radiological appearance of bony pelvis is vital for recognizing the early signs of various skeletal dysplasias. This article discusses many common and some uncommon radiological findings on pelvic radiographs along with the specific dysplasia in which they are seen; common differential diagnostic considerations are also discussed.

  15. The one-leg standing radiograph

    OpenAIRE

    Pinsornsak, P.; Naratrikun, K.; Kanitnate, S.; Sangkomkamhang, T.

    2016-01-01

    Objectives The purpose of this study was to compare the joint space width between one-leg and both-legs standing radiographs in order to diagnose a primary osteoarthritis of the knee. Methods Digital radiographs of 100 medial osteoarthritic knees in 50 patients were performed. The patients had undergone one-leg standing anteroposterior (AP) views by standing on the affected leg while a both-legs standing AP view was undertaken while standing on both legs. The severity of the osteoarthritis wa...

  16. Cardiac and pericardial calcifications on chest radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Ferguson, E.C., E-mail: ecferguson@hotmail.co [University of Texas Medical School at Houston, Department of Diagnostic and Interventional Imaging, Section of Thoracic Imaging, Houston, TX 77030 (United States); Berkowitz, E.A. [University of Texas Medical School at Houston, Department of Diagnostic and Interventional Imaging, Section of Thoracic Imaging, Houston, TX 77030 (United States)

    2010-09-15

    Many types of cardiac and pericardial calcifications identified on chest radiographs can be recognized and distinguished based on characteristic locations and appearances. The purpose of this review is to emphasize the importance of detecting cardiac and pericardial calcifications on chest radiographs, and to illustrate and describe the various types of calcifications that may be encountered and how they may be differentiated from one another. Each type of cardiac and pericardial calcification is discussed, its location and appearance described, and its significance explained. Recognizing and understanding these calcifications is important as they are often encountered in daily practice and play an important role in patient care.

  17. Pattern of scattered exposure from portable radiographs

    International Nuclear Information System (INIS)

    North, D.

    1985-01-01

    Concern periodically arises among the nursing and medical staffs of the institution's intensive care unit regarding their occupational exposure to radiation from the many radiographs taken in the unit. The patients are located in open areas or within individual cubicles whose walls are relatively thin and not shielded. To form a data base for educating the nursing/medical staffs and the technologists, the intensity and distribution of scattered exposure from actual radiographs of patients were measured. Comparison was also made with a simple phantom experiment in which the variables could be more precisely controlled

  18. Diagnosis of calcification on abdominal radiographs

    International Nuclear Information System (INIS)

    Lamb, C.R.; Kleine, L.J.; McMillan, M.C.

    1991-01-01

    A wide variety of normal and pathologic factors may induce intraabdominal calcification. In general, the most reliable indication of the cause of a calcification is its location; therefore, if the affected organ can be identified the radiographic diagnosis is often straightforward or, at least, limited to relatively few possibilities. With this principle in mind, a series of patients with abdominal calcification are described for the purpose of illustrating the appearance of calcification of various abdominal organs. In addition, etiology for the calcification in each patient is discussed. Certain extraabdominal calcifications which may be seen on abdominal radiographs are also mentioned

  19. Pseudoprominent aorta: Radiographic findings and CT correlation

    Energy Technology Data Exchange (ETDEWEB)

    Brown, K.T.; Shepard, J.A.O.; Stewart, W.J.

    1985-05-01

    The presence of a persistent left-sided superior vena cava (LSVC) in the absence of a right-sided superior vena cava (RSVC) may be suspected on a posteroanterior (PA) chest radiograph because of a prominent-appearing ascending aorta, which results from the absence of the RSVC. In the absence of an RSVC, the right upper lobe abuts and outlines the course of the ascending aorta, allowing better demonstration of its profile. This report describes a patient with this finding on a PA chest radiograph. Computed tomographic correlation is presented.

  20. Evaluation of contrast in duplicated radiographs

    International Nuclear Information System (INIS)

    Thunthy, K.H.; Weinberg, R.

    1982-01-01

    This investigation evaluated changes in the contrast of duplicated radiographs made at different ultraviolet light exposures. Increasing ultraviolet light exposure had different effects on the duplicates of originals of different background densities. When correctly exposed, a duplicate radiograph enhanced contrast. When originals had the same contrast but different background densities, their duplicates did not have the same contrast. It was not possible to duplicate accurately all the different contrasts measured on an original. It was possible, however, to produce duplicates with all contrasts greater than those of the original

  1. Radiographers' commitment to continuing professional development: A single-centre evaluation

    International Nuclear Information System (INIS)

    Stevens, Barry J.

    2016-01-01

    Purpose: This study aimed to examine radiographers' commitment to continuing professional development (CPD), and to ascertain what types of activities are preferred so a model for provision of departmental activities could be developed. Methods: An online survey was used to obtain information from all departmental radiographers regarding their commitment to CPD. Statistical analysis, using Spearman's Rho and Chi-Square test, was utilised to investigate any associations. Results: All radiographers (n = 57) were invited via email. A response rate of 67% (n = 38) prevailed. Radiographers feel CPD is important and a positive correlation existed with feelings regarding compulsory CPD (r value = .718, P value = .001). Thirty-four percent had logged the SOR-recommended twelve or more pieces of CPD in the last 2 years. One to three hours a month is the preferred amount of own time radiographers are willing to dedicate. Negative correlations exist between the amount of own time radiographers are willing to commit to CPD activities and their feelings regarding compulsory CPD (r value = −.419, P value = .009), and HCPC audit (r value = −.509, P value .001). Conclusion: Although radiographers recognise the importance of CPD many spend less than four hours of their own time a month on CPD. Departmental activities should be free, short lasting, lunchtime presentations with theory presentation that encourage interaction and discussion with inclusion of practical elements. Further research investigating the barriers that prevent radiographers from partaking in CPD and the causes for insufficient CPD records is recommended. - Highlights: • The large majority of radiographers feel CPD is important or very important to them. • The majority had positive opinions regarding compulsory CPD and HCPC audit. • 50% of radiographers commit less than 4 h of their own time to CPD. • As radiographers get older they log less CPD and commit less time to CPD.

  2. A radiographic study of the position and shape of mental foramen in panoramic radiographs

    International Nuclear Information System (INIS)

    Choi, Karp Shik; Kim, Dong Youn; Sohn, Jeong Ick; Bae, Yong Chul

    1997-01-01

    The purpose of this study was to evaluate the position and shape of mental foramen in panoramic radiographs. For this study, panoramic radiographs were obtained from the 200 adults and evaluated the position and shape of mental foramen. According to various positional changes in panoramic radiographs of the patients, the author also obtained panoramic radiographs from the 100 adults and then evaluated the positional and shape changes of mental foramen. The following results were obtained : 1. Shapes of mental foramen were observed elliptical (43.3%), round or oval (42.5%), unidentified (7.5%) and diffuse (6.7%) type in descending order of frequency. 2. Horizontal position of mental foramen were most frequently observed at the 2nd premolar area (54.2%), and area between the 1st premolar and 2nd premolar (43.1%), area between the 2nd premolar and 1st molar (2.7%), and at apex (9.7%), overlap with apex (1.9%), superior of apex (0.2%) in descending order of frequency. 4. According to various positional changes in panoramic radiographs of the patients, shape changes of mental foramen were more obviously observed at the forward 10 mm and chin down 10 degree positioned panoramic radiographs, And changes of horizontal and vertical position were observed in similar to compared with normal positioned panoramic radiographs.

  3. The radiographer's role in child protection: Comparison of radiographers perceptions by use of focus groups

    International Nuclear Information System (INIS)

    Davis, Michaela; Reeves, Pauline

    2006-01-01

    The research presented in this paper is taken from a larger study whose aims were to devise a holistic picture of how diagnostic radiographers approach child protection issues and to explore how radiographers and other professionals see the role of radiographers in the chain of evidence in relation to child protection as this applies to children who present at the Imaging Department with suspected non-accidental injuries (NAI). A focus group methodology was used with focus groups being conducted in the United Kingdom and Republic of Ireland. The results indicated that both United Kingdom and Republic of Ireland radiographers agreed that they had a role in child protection; however, they identified a wide interpretation as to the extent of that role. Although radiographers in the United Kingdom and Republic of Ireland work within different legal systems there were themes identified which were common to both countries. Although radiographers referred to a duty to the child as to all patients, no radiographer specifically mentioned the system and child care law under which it is assumed they operate. This research revealed an area which would benefit from more detailed research using a wider audience. However, the study revealed a need for training in relation to possible NAI indicators and the correct procedure for documenting their suspicions and initiating an NAI referral

  4. Radiographic Prevalence of Dysplasia, Cam, and Pincer Deformities in Elite Ballet.

    Science.gov (United States)

    Harris, Joshua D; Gerrie, Brayden J; Varner, Kevin E; Lintner, David M; McCulloch, Patrick C

    2016-01-01

    The demands of hip strength and motion in ballet are high. Hip disorders, such as cam and pincer deformities or dysplasia, may affect dance performance. However, the prevalence of these radiographic findings is unknown. To determine the prevalence of radiographic cam and pincer deformities, borderline dysplasia, and dysplasia in a professional ballet company. Cross-sectional study; Level of evidence, 3. An institutional review board-approved cross-sectional investigation of a professional ballet company was undertaken. Male and female adult dancers were eligible for inclusion. Four plain radiographs were obtained (standing anteroposterior pelvis, bilateral false profile, and supine Dunn 45°) and verified for adequacy. Cam and pincer deformities, dysplasia, borderline dysplasia, and osteoarthritis were defined. All plain radiographic parameters were measured and analyzed on available radiographs. Student t test, chi-square test (and Fisher exact test), and Spearman correlation analyses were performed to compare sexes, groups, and the effect of select radiographic criteria. A total of 47 dancers were analyzed (21 males, 26 females; mean age (±SD), 23.8 ± 5.4 years). Cam deformity was identified in 25.5% (24/94) of hips and 31.9% (15/47) of subjects, with a significantly greater prevalence in male dancers than females (48% hips and 57% subjects vs 8% hips and 12% subjects; P ballet company, a high prevalence of radiographic abnormalities was found, including cam and pincer deformity and dysplasia. The results also revealed several sex-related differences of these abnormalities in this unique population. The long-term implications of these findings in this group of elite athletes remain unknown, and this issue warrants future investigation. © 2015 The Author(s).

  5. Three-dimensional hindfoot alignment measurements based on biplanar radiographs: comparison with standard radiographic measurements

    International Nuclear Information System (INIS)

    Sutter, Reto; Pfirrmann, Christian W.A.; Buck, Florian M.; Espinosa, Norman

    2013-01-01

    To establish a hindfoot alignment measurement technique based on low-dose biplanar radiographs and compare with hindfoot alignment measurements on long axial view radiographs, which is the current reference standard. Long axial view radiographs and low-dose biplanar radiographs of a phantom consisting of a human foot skeleton embedded in acrylic glass (phantom A) and a plastic model of a human foot in three different hindfoot positions (phantoms B1-B3) were imaged in different foot positions (20 internal to 20 external rotation). Two independent readers measured hindfoot alignment on long axial view radiographs and performed 3D hindfoot alignment measurements based on biplanar radiographs on two different occasions. Time for three-dimensional (3D) measurements was determined. Intraclass correlation coefficients (ICC) were calculated. Hindfoot alignment measurements on long axial view radiographs were characterized by a large positional variation, with a range of 14 /13 valgus to 22 /27 varus (reader 1/2 for phantom A), whereas the range of 3D hindfoot alignment measurements was 7.3 /6.0 to 9.0 /10.5 varus (reader 1/2 for phantom A), with a mean and standard deviation of 8.1 ± 0.6/8.7 ± 1.4 respectively. Interobserver agreement was high (ICC = 0.926 for phantom A, and ICC = 0.886 for phantoms B1-B3), and agreement between different readouts was high (ICC = 0.895-0.995 for reader 1, and ICC = 0.987-0.994 for reader 2) for 3D measurements. Mean duration of 3D measurements was 84 ± 15/113 ± 15 s for reader 1/2. Three-dimensional hindfoot alignment measurements based on biplanar radiographs were independent of foot positioning during image acquisition and reader independent. In this phantom study, the 3D measurements were substantially more precise than the standard radiographic measurements. (orig.)

  6. Improvement in Detection of Wrong-Patient Errors When Radiologists Include Patient Photographs in Their Interpretation of Portable Chest Radiographs.

    Science.gov (United States)

    Tridandapani, Srini; Olsen, Kevin; Bhatti, Pamela

    2015-12-01

    This study was conducted to determine whether facial photographs obtained simultaneously with radiographs improve radiologists' detection rate of wrong-patient errors, when they are explicitly asked to include the photographs in their evaluation. Radiograph-photograph combinations were obtained from 28 patients at the time of portable chest radiography imaging. From these, pairs of radiographs were generated. Each unique pair consisted of one new and one old (comparison) radiograph. Twelve pairs of mismatched radiographs (i.e., pairs containing radiographs of different patients) were also generated. In phase 1 of the study, 5 blinded radiologist observers were asked to interpret 20 pairs of radiographs without the photographs. In phase 2, each radiologist interpreted another 20 pairs of radiographs with the photographs. Radiologist observers were not instructed about the purpose of the photographs but were asked to include the photographs in their review. The detection rate of mismatched errors was recorded along with the interpretation time for each session for each observer. The two-tailed Fisher exact test was used to evaluate differences in mismatch detection rates between the two phases. A p value of error detection rates without (0/20 = 0%) and with (17/18 = 94.4%) photographs were different (p = 0.0001). The average interpretation times for the set of 20 radiographs were 26.45 (SD 8.69) and 20.55 (SD 3.40) min, for phase 1 and phase 2, respectively (two-tailed Student t test, p = 0.1911). When radiologists include simultaneously obtained photographs in their review of portable chest radiographs, there is a significant improvement in the detection of labeling errors. No statistically significant difference in interpretation time was observed. This may lead to improved patient safety without affecting radiologists' throughput.

  7. Reliability of radiographic observations recorded on a proforma measured using inter- and intra-observer variation: a preliminary study.

    Science.gov (United States)

    Saunders, M B; Gulabivala, K; Holt, R; Kahan, R S

    2000-05-01

    The aim of this preliminary study was to test the reliability of radiographic evaluation of features of endodontic interest using a newly devised data collection system. Twelve endodontic MSc postgraduate students and one specialist endodontist examined sample radiographs derived from a random selection of 42 patients seen previously on an Endodontic New Patient Clinic (EDI). Each student examined a random selection of 8-9 roots on periapical radiographs of single- and multirooted teeth, with and without previous root canal therapy and 3-4 dental panoramic tomograms (DPTs). A total of 100 roots were examined. A proforma was used to record observations on 67 radiographic features using predefined criteria. Intra-observer agreement was tested by asking the students to re-examine the radiographs. The principle investigator and the specialist endodontist examined the same radiographs and devised a Gold Standard using the same criteria. This was compared with the student assessments to determine inter-observer variation. The postgraduates then attended a revision session on the use of the form. Each student subsequently examined 8-9 different roots from the pool of radiographs. A further assessment of inter-observer variation was made by comparing these observations with the Gold Standard. Of the 67 radiographic features, only 25 had sufficient response to allow statistical analysis. Kappa values for intra- and inter-observer variation were estimated. These varied depending on the particular radiographic feature being assessed. Fifteen out of 25 intra-observer recordings showed 'good' or 'very good' Kappa agreement, but only three out of 25 inter-observer observations achieved 'good' or 'very good' values. Inter-observer variation was improved following the revision session with 16 out of 25 observations achieving 'good' or 'very good' Kappa agreement. Modification to the proforma, the criteria used, and training for radiographic assessment were considered necessary to

  8. Radiographer commenting of trauma radiographs: a survey of the benefits, barriers and enablers to participation in an Australian healthcare setting

    International Nuclear Information System (INIS)

    Neep, Michael J.; Steffens, Tom; Owen, Rebecca; McPhail, Steven M.

    2014-01-01

    Radiographer abnormality detection systems that highlight abnormalities on trauma radiographs ('red dot' system) have been operating for more than 30 years. Recently, a number of pitfalls have been identified. These limitations initiated the evolution of a radiographer commenting system, whereby a radiographer provides a brief description of abnormalities identified in emergency healthcare settings. This study investigated radiographers' participation in abnormality detection systems, their perceptions of benefits, barriers and enablers to radiographer commenting, and perceptions of potential radiographer image interpretation services for emergency settings. A cross-sectional survey was implemented. Participants included radiographers from four metropolitan hospitals in Queensland, Australia. Conventional descriptive statistics, histograms and thematic analysis were undertaken. Seventy-three surveys were completed and included in the analysis (68% response rate); 30 (41%) of respondents reported participating in abnormality detection in 20% or less of examinations, and 26(36%) reported participating in 80% or more of examinations. Five overarching perceived benefits of radiographer commenting were identified: assisting multidisciplinary teams, patient care, radiographer ability, professional benefits and quality of imaging. Frequently reported perceived barriers included 'difficulty accessing image interpretation education', 'lack of time' and 'low confidence in interpreting radiographs'. Perceived enablers included 'access to image interpretation education' and 'support from radiologist colleagues'. A range of factors are likely to contribute to the successful implementation of radiographer commenting in addition to abnormality detection in emergency settings. Effective image interpretation education amenable to completion by radiographers would likely prove valuable in preparing radiographers for participation in abnormality detection and commenting systems in

  9. The use of wind tunnel facilities to estimate hydrodynamic data

    Science.gov (United States)

    Hoffmann, Kristoffer; Tophøj Rasmussen, Johannes; Hansen, Svend Ole; Reiso, Marit; Isaksen, Bjørn; Egeberg Aasland, Tale

    2016-03-01

    Experimental laboratory testing of vortex-induced structural oscillations in flowing water is an expensive and time-consuming procedure, and the testing of high Reynolds number flow regimes is complicated due to the requirement of either a large-scale or high-speed facility. In most cases, Reynolds number scaling effects are unavoidable, and these uncertainties have to be accounted for, usually by means of empirical rules-of-thumb. Instead of performing traditional hydrodynamic measurements, wind tunnel testing in an appropriately designed experimental setup may provide an alternative and much simpler and cheaper framework for estimating the structural behavior under water current and wave loading. Furthermore, the fluid velocities that can be obtained in a wind tunnel are substantially higher than in a water testing facility, thus decreasing the uncertainty from scaling effects. In a series of measurements, wind tunnel testing has been used to investigate the static response characteristics of a circular and a rectangular section model. Motivated by the wish to estimate the vortex-induced in-line vibration characteristics of a neutrally buoyant submerged marine structure, additional measurements on extremely lightweight, helium-filled circular section models were conducted in a dynamic setup. During the experiment campaign, the mass of the model was varied in order to investigate how the mass ratio influences the vibration amplitude. The results show good agreement with both aerodynamic and hydrodynamic experimental results documented in the literature.

  10. Anisotropic hydrodynamics for conformal Gubser flow

    Energy Technology Data Exchange (ETDEWEB)

    Strickland, Michael; Nopoush, Mohammad [Kent State University, Kent OH 44242 (United States); Ryblewski, Radoslaw [The H. Niewodniczański Institute of Nuclear Physics, Polish Academy of Sciences, PL-31342 Kraków (Poland)

    2016-12-15

    In this proceedings contribution, we review the exact solution of the anisotropic hydrodynamics equations for a system subject to Gubser flow. For this purpose, we use the leading-order anisotropic hydrodynamics equations which assume that the distribution function is ellipsoidally symmetric in local-rest-frame momentum. We then prove that the SO(3){sub q} symmetry in de Sitter space constrains the anisotropy tensor to be of spheroidal form with only one independent anisotropy parameter remaining. As a consequence, the exact solution reduces to the problem of solving two coupled non-linear differential equations. We show that, in the limit that the relaxation time goes to zero, one obtains Gubser's ideal hydrodynamic solution and, in the limit that the relaxation time goes to infinity, one obtains the exact free streaming solution obtained originally by Denicol et al. For finite relaxation time, we solve the equations numerically and compare to the exact solution of the relaxation-time-approximation Boltzmann equation subject to Gubser flow. Using this as our standard, we find that anisotropic hydrodynamics describes the spatio-temporal evolution of the system better than all currently known dissipative hydrodynamics approaches.

  11. Hydrodynamic Modeling and Its Application in AUC.

    Science.gov (United States)

    Rocco, Mattia; Byron, Olwyn

    2015-01-01

    The hydrodynamic parameters measured in an AUC experiment, s(20,w) and D(t)(20,w)(0), can be used to gain information on the solution structure of (bio)macromolecules and their assemblies. This entails comparing the measured parameters with those that can be computed from usually "dry" structures by "hydrodynamic modeling." In this chapter, we will first briefly put hydrodynamic modeling in perspective and present the basic physics behind it as implemented in the most commonly used methods. The important "hydration" issue is also touched upon, and the distinction between rigid bodies versus those for which flexibility must be considered in the modeling process is then made. The available hydrodynamic modeling/computation programs, HYDROPRO, BEST, SoMo, AtoB, and Zeno, the latter four all implemented within the US-SOMO suite, are described and their performance evaluated. Finally, some literature examples are presented to illustrate the potential applications of hydrodynamics in the expanding field of multiresolution modeling. © 2015 Elsevier Inc. All rights reserved.

  12. Anisotropic hydrodynamics for conformal Gubser flow

    International Nuclear Information System (INIS)

    Strickland, Michael; Nopoush, Mohammad; Ryblewski, Radoslaw

    2016-01-01

    In this proceedings contribution, we review the exact solution of the anisotropic hydrodynamics equations for a system subject to Gubser flow. For this purpose, we use the leading-order anisotropic hydrodynamics equations which assume that the distribution function is ellipsoidally symmetric in local-rest-frame momentum. We then prove that the SO(3)_q symmetry in de Sitter space constrains the anisotropy tensor to be of spheroidal form with only one independent anisotropy parameter remaining. As a consequence, the exact solution reduces to the problem of solving two coupled non-linear differential equations. We show that, in the limit that the relaxation time goes to zero, one obtains Gubser's ideal hydrodynamic solution and, in the limit that the relaxation time goes to infinity, one obtains the exact free streaming solution obtained originally by Denicol et al. For finite relaxation time, we solve the equations numerically and compare to the exact solution of the relaxation-time-approximation Boltzmann equation subject to Gubser flow. Using this as our standard, we find that anisotropic hydrodynamics describes the spatio-temporal evolution of the system better than all currently known dissipative hydrodynamics approaches.

  13. Applying the technology of hydrodynamic cavitation treatment of high-viscosity oils to increase the efficiency of transportation

    Science.gov (United States)

    Brand, A. E.; Vershinina, S. V.; Vengerov, A. A.; Mostovaya, N. A.

    2015-10-01

    The article investigates the possibility of applying hydrodynamic cavitation treatment to reduce oil viscosity in Russian pipeline transportation system and increase its performance. The result of laboratory tests and suggestions on technology application are given

  14. Automatic evaluation of radiographs with the REBUS system

    International Nuclear Information System (INIS)

    Keck, R.; Coen, G.

    1987-01-01

    Digital image processing has become a top rank quality assurance method in industry in the last few years, and still promises improvements in future. One of the main reasons of this development is the fact that for specific applications, digital image processing has matured from simple image processing (deletion of unimportant marginal data, edge detection, signal-to-noise improvement) to automatic image evaluation. As an example of such specific applications, the article explains the detection and classification of flows in welded seams or joints by means of radiographic testing. (orig./HP) [de

  15. Digital radiographic scanning installation with multiwire proportional chamber

    International Nuclear Information System (INIS)

    Babichev, E.A.; Baru, S.E.; Khabakhpashev, A.G.; Kolachev, G.M.; Savinov, G.A.; Shekhtman, L.I.; Sidorov, V.A.; Volobuev, A.I.

    1991-01-01

    A digital radiographic installation for medical diagnostics is described. Distribution of X-ray intensity in horizontal direction is measured by a one-coordinate MWPC with a 1.2 mm channel. A two-dimensional image is produced by mechanical scanning with 1 mm channel width in vertical direction. The number of pixels in the image is 320x256. The MWPC works in count mode with quantum efficiency 25% (50 keV) and count rate capability 600 kHz/channel. Results of testing a prototype with 64 channels 0.6 mm width are also presented. (orig.)

  16. Validation of the plain chest radiograph for epidemiologic studies of airflow obstruction

    International Nuclear Information System (INIS)

    Musk, A.W.

    1982-01-01

    The chest radiographs of 125 industrial workers from rural New South Wales were examined for overinflated lungs, with and without attenuated midzonal vessels. Although the mean values of a comprehensive range of pulmonary function tests in the whole group were within normal limits, the nine subjects whose radiographs showed overinflated lungs and attenuated vessels had significantly impaired pulmonary function in comparison with 85 subjects with normal radiographs. The mean values for these nine subjects, expressed as a percentage of the mean value for subjects with normal radiographs, were: forced expiratory volume in 1 second, 75%; total lung capacity, 107%; residual volume, 143%; transpulmonary pressure at maximum inspiration, 60%; static deflation compliance, 158%; lung volume at transpulmonary pressure 10 cm H 2 O, 132%; transfer factor, 79%; and transfer factor/alveolar volume, 77%. Similar results were obtained by a second observer. Those subjects with overinflation but no vascular attenuation had significantly larger mean values for vital capacity and alveolar volume but no significant difference in total lung capacity or other tests of the mechanical properties of the lungs. Agreement on the presence of a positive sign between the two observers expressed as a percentage of those considered positive by either was 81% for overinflation and 62% for attenuated midzonal vessels. The results indicate that in groups of subjects with normal-average values of pulmonary function, the plain chest radiograph may provide information concerning pulmonary structure that is reflected in tests of function

  17. Ergonomic strategies to improve radiographers' posture during mammography activities.

    Science.gov (United States)

    Cernean, Nicolai; Serranheira, Florentino; Gonçalves, Pedro; Sá Dos Reis, Cláudia

    2017-08-01

    To identify alternatives for radiographers' postures while performing mammography that can contribute to reduce the risk of work-related musculoskeletal disorders (WRMSDs). Radiographers' postures to positioning craniocaudal (CC) and mediolateral oblique (MLO) views were simulated without any intervention for three scenarios: radiographer/patient with similar statures, radiographer smaller than patient and radiographer taller than patient. Actions were taken to modify the postures: seated radiographer; patient on a step; seated patient; radiographer on a step. All the postures were analysed using kinovea 0.8.15 software and the angles were measured twice and classified according to European standard EN1005-4: 2005. The non-acceptable angles were measured mainly during MLO positioning when radiographer was taller than the patient: 139° and 120° for arm-flexion and abduction, 72° for trunk and -24° for head/neck-flexion. The introduction of alternative postures (radiographer seated), allowed improvements in posture (60° and 99° for arm flexion and abduction, 14° for trunk and 0° for head/neck flexion), being classified as acceptable. The alternative postures simulated have the potential to reduce the risk of developing WRMSDs when radiographers and patients have different statures. • Radiographers' postures in mammography can contribute to work-related musculoskeletal disorders • Non-acceptable posture was identified for MLO breast positioning (radiographer taller than patient) • Adapting posture to patient biotype reduces the WRMSD risk for radiographers.

  18. Study on transient hydrodynamic performance and cavitation characteristic of high-speed mixed-flow pump

    International Nuclear Information System (INIS)

    Chen, T; Liu, Y L; Sun, Y B; Wang, L Q; Wu, D Z

    2013-01-01

    In order to analyse the hydrodynamic performance and cavitation characteristic of a high-speed mixed-flow pump during transient operations, experimental studies were carried out. The transient hydrodynamic performance and cavitation characteristics of the mixed-flow pump with guide vane during start-up operation processes were tested on the pump performance test-bed. Performance tests of the pump were carried out under various inlet pressures and speed-changing operations. The real-time instantaneous external characteristics such as rotational speed, hydraulic head, flow rate, suction pressure and discharge pressure of the pump were measured. Based on the experimental results, the effect of fluid acceleration on the hydrodynamic performances and cavitation characteristics of the mixed-flow pump were analysed and evaluated

  19. Algorithms for boundary detection in radiographic images

    International Nuclear Information System (INIS)

    Gonzaga, Adilson; Franca, Celso Aparecido de

    1996-01-01

    Edge detecting techniques applied to radiographic digital images are discussed. Some algorithms have been implemented and the results are displayed to enhance boundary or hide details. An algorithm applied in a pre processed image with contrast enhanced is proposed and the results are discussed

  20. Comparison of radiographic technique by computer simulation

    International Nuclear Information System (INIS)

    Brochi, M.A.C.; Ghilardi Neto, T.

    1989-01-01

    A computational algorithm to compare radiographic techniques (KVp, mAs and filters) is developed based in the fixation of parameters that defines the images, such as optical density and constrast. Before the experience, the results were used in a radiography of thorax. (author) [pt

  1. Detecting objects in radiographs for homeland security

    Science.gov (United States)

    Prasad, Lakshman; Snyder, Hans

    2005-05-01

    We present a general scheme for segmenting a radiographic image into polygons that correspond to visual features. This decomposition provides a vectorized representation that is a high-level description of the image. The polygons correspond to objects or object parts present in the image. This characterization of radiographs allows the direct application of several shape recognition algorithms to identify objects. In this paper we describe the use of constrained Delaunay triangulations as a uniform foundational tool to achieve multiple visual tasks, namely image segmentation, shape decomposition, and parts-based shape matching. Shape decomposition yields parts that serve as tokens representing local shape characteristics. Parts-based shape matching enables the recognition of objects in the presence of occlusions, which commonly occur in radiographs. The polygonal representation of image features affords the efficient design and application of sophisticated geometric filtering methods to detect large-scale structural properties of objects in images. Finally, the representation of radiographs via polygons results in significant reduction of image file sizes and permits the scalable graphical representation of images, along with annotations of detected objects, in the SVG (scalable vector graphics) format that is proposed by the world wide web consortium (W3C). This is a textual representation that can be compressed and encrypted for efficient and secure transmission of information over wireless channels and on the Internet. In particular, our methods described here provide an algorithmic framework for developing image analysis tools for screening cargo at ports of entry for homeland security.

  2. 21 CFR 1020.31 - Radiographic equipment.

    Science.gov (United States)

    2010-04-01

    ...) RADIOLOGICAL HEALTH PERFORMANCE STANDARDS FOR IONIZING RADIATION EMITTING PRODUCTS § 1020.31 Radiographic... and time, a preset number of pulses, or a preset radiation exposure to the image receptor. (i) Except... exposure of greater than one-half second. Except during panoramic dental radiography, termination of...

  3. Radiographic contrast media, function and future reassessed

    International Nuclear Information System (INIS)

    Sovak, M.

    1988-01-01

    A brief review is given of the use of radiographic contrast media in cholecysto- and cholangiography, central nervous system imaging, urography and angiography. Other aspects briefly discussed are the use of large i.v. doses of contrast media for CT contrast enhancement and the design theory for improved water soluble contrast media. (U.K.)

  4. Radiographic analysis of ameloblastoma: A retrospective study

    Directory of Open Access Journals (Sweden)

    Chandramani More

    2012-01-01

    Conclusion: Radiographs are an important aid for the diagnosis of oral lesions of various types, especially those that involve bone. It is important for the practicing clinicians to know the salient features of ameloblastoma which are peculiar to the local population.

  5. The radiographic investigation of two Egyptian mummies.

    Science.gov (United States)

    Fodor, J; Malott, J C; King, A Y

    1983-01-01

    Radiography is a well-recognized method of nondestructive analysis of art objects and ancient relics. The methods and techniques used in the examination of two ancient Egyptian mummies are presented here. Additionally, the use of radiographic findings to help substantiate alleged historical information and to establish sex, age, and pathology of each specimen is discussed.

  6. Unusual radiographic changes of a gout patient

    International Nuclear Information System (INIS)

    Markota, J.

    2004-01-01

    Background. Gout is a metabolic disorder that results in hyperuricemia and accumulation of uric acid crystals (urats) in tissues, especially joint cartilage. The gouty arthritis presents as acute attacks of arthritis leading eventually to chronic gouty arthritis. In 80% of cases it first occurs in the matatarsophalangeal (MTP) joint of the great toe and is more frequent in male population. Case report. We present a case of unusual radiographic changes accompanying gouty arthritis. A 63 year old female complained about swelling of the first MTP joint on the right, right knee, about stiffness of feet and hands' digits and about backache. First symptoms started to appear 30 years ago. In the time of examination radiographs displayed degenerative changes of the majority of presented joints, bilateral sacroiliitis and osseous ankylosis of both insteps. Microscopic examination showed urate crystals in the samples of the synovial fluid aspirated from the knee. The histological findings of the synovial tissue after the synovectomy were also in favour of gouty arthritis. Conclusions. Radiographs are the most important imaging modality in the diagnostic process of gout. However, radiographic differential diagnosis can be difficult, since the findings overlap with other conditions which cause arthritis and osteoarthritis especially in longstanding gout, elderly patients and females. The diagnosis must be often confirmed with the help of laboratory and histological findings. (author)

  7. Transfer function analysis of radiographic imaging systems

    International Nuclear Information System (INIS)

    Metz, C.E.; Doi, K.

    1979-01-01

    The theoretical and experimental aspects of the techniques of transfer function analysis used in radiographic imaging systems are reviewed. The mathematical principles of transfer function analysis are developed for linear, shift-invariant imaging systems, for the relation between object and image and for the image due to a sinusoidal plane wave object. The other basic mathematical principle discussed is 'Fourier analysis' and its application to an input function. Other aspects of transfer function analysis included are alternative expressions for the 'optical transfer function' of imaging systems and expressions are derived for both serial and parallel transfer image sub-systems. The applications of transfer function analysis to radiographic imaging systems are discussed in relation to the linearisation of the radiographic imaging system, the object, the geometrical unsharpness, the screen-film system unsharpness, other unsharpness effects and finally noise analysis. It is concluded that extensive theoretical, computer simulation and experimental studies have demonstrated that the techniques of transfer function analysis provide an accurate and reliable means for predicting and understanding the effects of various radiographic imaging system components in most practical diagnostic medical imaging situations. (U.K.)

  8. Radiographic Features of Acute Patellar Tendon Rupture.

    Science.gov (United States)

    Fazal, Muhammad Ali; Moonot, Pradeep; Haddad, Fares

    2015-11-01

    The purpose of our study was to assess soft tissue features of acute patellar tendon rupture on lateral knee radiograph that would facilitate early diagnosis. The participants were divided into two groups of 35 patients each. There were 28 men and seven women with a mean age of 46 years in the control group and 26 men and nine women with a mean age of 47 years in the rupture group. The lateral knee radiograph of each patient was evaluated for Insall-Salvati ratio for patella alta, increased density of the infrapatellar fat pad, appearance of the soft tissue margin of the patellar tendon and bony avulsions. In the rupture group there were three consistent soft tissue radiographic features in addition to patellar alta. These were increased density of infrapatellar fat pad; loss of sharp, well-defined linear margins of the patellar tendon and angulated wavy margin of the patellar tendon while in the control group these features were not observed. The soft tissue radiographic features described in the rupture group are consistent and reliable. When coupled with careful clinical assessment, these will aid in early diagnosis and further imaging will be seldom required. © 2015 Chinese Orthopaedic Association and Wiley Publishing Asia Pty Ltd.

  9. Chest radiographic findings in Human Immunodeficiency Virus ...

    African Journals Online (AJOL)

    This study was carried out to determine findings on chest radiographs in HIV positive/AIDS patients at the University of Benin Teaching Hospital (UBTH) Benin City. All consecutive HIV positive/AIDS patients, managed at the UBTH between 1991 and 2001 were included in the study. Patients had postero-anterior (PA) chest ...

  10. Thoracic radiographic anatomy in goats | Makungu | Tanzania ...

    African Journals Online (AJOL)

    The aim of this study was to describe the normal radiographic anatomy of the thorax of small East African goats as a reference for clinical use. Radiography of the thorax was performed under general anaesthesia in 10 healthy small East African goats. Right lateral (RL), left lateral (LL), dorsoventral (DV) and ventrodorsal ...

  11. Radiographic analysis of pasteurized autologous bone graft

    International Nuclear Information System (INIS)

    Ahmed, Adel Refaat; Manabe, Jun; Kawaguchi, Noriyoshi; Matsumoto, Seiichi; Matsushita, Yasushi

    2003-01-01

    Local malignant bone tumor excision followed by pasteurization and subsequent reimplantation is a unique technique for reconstruction after resection of primary bone sarcomas. The purpose of this investigation was to assess the normal and abnormal long-term radiographic findings of intercalary and osteo-chondral pasteurized bone graft/implant composite. The long-term radiographic findings of pasteurized bone grafts used in reconstruction after resection of bone and soft tissue sarcomas in relation to patients' clinical data were reviewed retrospectively. Thirty-one patients (18 females, 13 males; age range 7-77 years, mean 30 years) who underwent surgery between April 1990 and January 1997 at the authors' institute constituted the material of this study. They were followed up for at least 3 years or until the patient's death (mean 69 months). The International Society of Limb Salvage graft evaluation method that assesses the fusion, resorption, fracture, graft shortening, fixation, subluxation, joint narrowing and subchondral bone was used for evaluation of the radiographs. Twenty-one patients (68%) showed complete incorporation of graft and eight patients (26%) had partial incorporation. The overall radiographic evaluation rate was 81%. Fracture (10%) and infection (16%) were the main complications. No local recurrence was detected. These results indicate that pasteurization of bone is a useful option for reconstruction after resection of malignant bone tumors. (orig.)

  12. The screening pelvic radiograph in pediatric trauma

    International Nuclear Information System (INIS)

    Rees, M.J.; Aickin, R.; Kolbe, A.; Teele, R.L.

    2001-01-01

    Background. Pelvic radiographs are routinely obtained in adult trauma to optimise early management. In adults, pelvic fractures are associated with high early transfusion requirement, high injury severity scores and an increased incidence of other abdominal and thoracic injuries. It is unclear whether this holds true in children. Objective. To determine whether the screening pelvic radiograph is necessary in paediatric trauma. Materials and methods. The notes of all patients who presented after trauma to the Starship Children's Hospital and were triaged to the resuscitation room during 1997 were reviewed. Results of initial radiography were obtained and correlated with later imaging. Results. Our review of 444 injured children seen over a period of 1 year revealed that of 347 children who had screening pelvic radiographs, only 1 had a pelvic fracture. The fracture in this child was clinically apparent and required no specific treatment. Conclusions. The presence of a pelvic fracture is rare in injured children. By omitting screening pelvic radiographs there are potential benefits, including reduced radiation exposure to children and cost savings. Uninterpretable or abnormal clinical examination or haematuria requires further investigation, but routine screening for pelvic fracture is unnecessary. (orig.)

  13. Radiographic analysis of pasteurized autologous bone graft

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Adel Refaat [Department of Orthopedic Surgery, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Kamiikebukuro 1-37-1, Toshima-ku, 170-0012, Tokyo (Japan); Department of Orthopedic Surgery, Alexandria University, Alexandria (Egypt); Manabe, Jun; Kawaguchi, Noriyoshi; Matsumoto, Seiichi; Matsushita, Yasushi [Department of Orthopedic Surgery, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Kamiikebukuro 1-37-1, Toshima-ku, 170-0012, Tokyo (Japan)

    2003-08-01

    Local malignant bone tumor excision followed by pasteurization and subsequent reimplantation is a unique technique for reconstruction after resection of primary bone sarcomas. The purpose of this investigation was to assess the normal and abnormal long-term radiographic findings of intercalary and osteo-chondral pasteurized bone graft/implant composite. The long-term radiographic findings of pasteurized bone grafts used in reconstruction after resection of bone and soft tissue sarcomas in relation to patients' clinical data were reviewed retrospectively. Thirty-one patients (18 females, 13 males; age range 7-77 years, mean 30 years) who underwent surgery between April 1990 and January 1997 at the authors' institute constituted the material of this study. They were followed up for at least 3 years or until the patient's death (mean 69 months). The International Society of Limb Salvage graft evaluation method that assesses the fusion, resorption, fracture, graft shortening, fixation, subluxation, joint narrowing and subchondral bone was used for evaluation of the radiographs. Twenty-one patients (68%) showed complete incorporation of graft and eight patients (26%) had partial incorporation. The overall radiographic evaluation rate was 81%. Fracture (10%) and infection (16%) were the main complications. No local recurrence was detected. These results indicate that pasteurization of bone is a useful option for reconstruction after resection of malignant bone tumors. (orig.)

  14. Correlation Of Radiographic Patterns Of Pulmonary Tuberculosis ...

    African Journals Online (AJOL)

    Patients with higher CD4+ counts often present in \\"classic\\" fashion (upper zone infiltrates cavities) whereas those with low CD4+ counts are more likely to present atypically. The chest radiographic appearances of HIV-seropositive patients presenting with pulmonary tuberculosis (PTB) are diverse, creating difficulty in ...

  15. Effects of rotation radiographic dimensions of metacarpals

    International Nuclear Information System (INIS)

    Armes, F.M.; Horsman, A.; Bentley, H.B.

    1979-01-01

    An experiment is described which shows that small rotations of metacarpals about their long axis produce small systematic changes in the cortical dimensions as measured by radiographic morphometry. The effect is of no significance in cross-sectional studies but is an important source of error in sequential studies. (author)

  16. A theoretical study of hydrodynamic cavitation.

    Science.gov (United States)

    Arrojo, S; Benito, Y

    2008-03-01

    The optimization of hydrodynamic cavitation as an AOP requires identifying the key parameters and studying their effects on the process. Specific simulations of hydrodynamic bubbles reveal that time scales play a major role on the process. Rarefaction/compression periods generate a number of opposing effects which have demonstrated to be quantitatively different from those found in ultrasonic cavitation. Hydrodynamic cavitation can be upscaled and offers an energy efficient way of generating cavitation. On the other hand, the large characteristic time scales hinder bubble collapse and generate a low number of cavitation cycles per unit time. By controlling the pressure pulse through a flexible cavitation chamber design these limitations can be partially compensated. The chemical processes promoted by this technique are also different from those found in ultrasonic cavitation. Properties such as volatility or hydrophobicity determine the potential applicability of HC and therefore have to be taken into account.

  17. Shear viscosity, cavitation and hydrodynamics at LHC

    International Nuclear Information System (INIS)

    Bhatt, Jitesh R.; Mishra, Hiranmaya; Sreekanth, V.

    2011-01-01

    We study evolution of quark-gluon matter in the ultrarelativistic heavy-ion collisions within the frame work of relativistic second-order viscous hydrodynamics. In particular, by using the various prescriptions of a temperature-dependent shear viscosity to the entropy ratio, we show that the hydrodynamic description of the relativistic fluid becomes invalid due to the phenomenon of cavitation. For most of the initial conditions relevant for LHC, the cavitation sets in very early stage. The cavitation in this case is entirely driven by the large values of shear viscosity. Moreover we also demonstrate that the conformal terms used in equations of the relativistic dissipative hydrodynamic can influence the cavitation time.

  18. The RAGE radiation-hydrodynamic code

    Energy Technology Data Exchange (ETDEWEB)

    Gittings, Michael; Clover, Michael; Betlach, Thomas; Byrne, Nelson; Ranta, Dale [Science Applications International Corp. MS A-1, 10260 Campus Point Drive, San Diego, CA 92121 (United States); Weaver, Robert; Coker, Robert; Dendy, Edward; Hueckstaedt, Robert; New, Kim; Oakes, W Rob [Los Alamos National Laboratory, MS T087, PO Box 1663, Los Alamos, NM 87545 (United States); Stefan, Ryan [TaylorMade-adidas Golf, 5545 Fermi Court, Carlsbad, CA 92008-7324 (United States)], E-mail: michael.r.clover@saic.com

    2008-10-01

    We describe RAGE, the 'radiation adaptive grid Eulerian' radiation-hydrodynamics code, including its data structures, its parallelization strategy and performance, its hydrodynamic algorithm(s), its (gray) radiation diffusion algorithm, and some of the considerable amount of verification and validation efforts. The hydrodynamics is a basic Godunov solver, to which we have made significant improvements to increase the advection algorithm's robustness and to converge stiffnesses in the equation of state. Similarly, the radiation transport is a basic gray diffusion, but our treatment of the radiation-material coupling, wherein we converge nonlinearities in a novel manner to allow larger timesteps and more robust behavior, can be applied to any multi-group transport algorithm.

  19. The RAGE radiation-hydrodynamic code

    International Nuclear Information System (INIS)

    Gittings, Michael; Clover, Michael; Betlach, Thomas; Byrne, Nelson; Ranta, Dale; Weaver, Robert; Coker, Robert; Dendy, Edward; Hueckstaedt, Robert; New, Kim; Oakes, W Rob; Stefan, Ryan

    2008-01-01

    We describe RAGE, the 'radiation adaptive grid Eulerian' radiation-hydrodynamics code, including its data structures, its parallelization strategy and performance, its hydrodynamic algorithm(s), its (gray) radiation diffusion algorithm, and some of the considerable amount of verification and validation efforts. The hydrodynamics is a basic Godunov solver, to which we have made significant improvements to increase the advection algorithm's robustness and to converge stiffnesses in the equation of state. Similarly, the radiation transport is a basic gray diffusion, but our treatment of the radiation-material coupling, wherein we converge nonlinearities in a novel manner to allow larger timesteps and more robust behavior, can be applied to any multi-group transport algorithm

  20. Coronal and Intraradicular Appearances Affect Radiographic Perception of the Periapical Region.

    Science.gov (United States)

    Strong, Julie W; Woodmansey, Karl F; Khademi, John A; Hatton, John F

    2017-05-01

    The influence of the radiographic appearances of the coronal and intraradicular areas on periapical radiographic interpretation has been minimally evaluated in dentistry and endodontics. The purpose of this study was to evaluate the effects that the coronal and intraradicular radiographic appearance has on endodontists' radiographic interpretations of periapical areas. In a split-group study design using an online survey format, 2 pairs of digital periapical radiographic images were evaluated by 2 groups (A and B) of endodontist readers for the presence of a periapical finding. The images in each pair were identical except that 1 image of each image pairs had coronal restorations and/or root canal fillings altered using Adobe Photoshop software (Adobe Systems, San Jose, CA). The periapical areas were not altered. Using a 5-point Likert scale, the endodontist readers were asked to "Please evaluate the periapical area(s)." A Mann-Whitney U test was used to statistically evaluate the difference between the groups. Significance was set at P < .01. There were 417 readers in group A and 442 readers in group B. The Mann-Whitney U test showed a significant difference in the responses between the groups for both image pairs (P < .01). Because the periapical areas of the image pairs were unaltered, the differing coronal and intraradicular areas of the radiographs appear to have influenced endodontists' interpretations of the periapical areas. This finding has implications for all radiographic outcome assessments. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.