WorldWideScience

Sample records for radiographic hydrodynamic test

  1. Dual Axis Radiographic Hydrodynamic Test Facility mitigation action plan. Annual report for 1998

    International Nuclear Information System (INIS)

    Haagenstad, T.

    1999-01-01

    This Mitigation Action Plan Annual Report (MAPAR) has been prepared as part of implementing the Dual Axis Radiographic Hydrodynamic Test Facility (DARHT) Mitigation Action Plan (MAP) to protect workers, soils, water, and biotic and cultural resources in and around the facility

  2. Dual Axis Radiographic Hydrodynamic Test Facility mitigation action plan. Annual report for 1998

    Energy Technology Data Exchange (ETDEWEB)

    Haagenstad, T.

    1999-01-15

    This Mitigation Action Plan Annual Report (MAPAR) has been prepared as part of implementing the Dual Axis Radiographic Hydrodynamic Test Facility (DARHT) Mitigation Action Plan (MAP) to protect workers, soils, water, and biotic and cultural resources in and around the facility.

  3. Radiographic Test

    Energy Technology Data Exchange (ETDEWEB)

    Lee, H.J; Yang, S.H. [Korea Electric Power Research Institute, Taejon (Korea)

    2002-07-01

    This report contains theory, procedure technique and interpretation of radiographic examination and written for whom preparing radiographic test Level II. To determine this baseline of technical competence in the examination, the individual must demonstrate a knowledge of radiography physics, radiation safety, technique development, radiation detection and measurement, facility design, and the characteristics of radiation-producing devices and their principles of operation. (author) 98 figs., 23 tabs.

  4. Dual axis radiographic hydrodynamic test facility. Final environmental impact statement, Volume 2: Public comments and responses

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-08-01

    On May 12, 1995, the U.S. Department of Energy (DOE) issued the draft Dual Axis Radiographic Hydrodynamic Test Facility Environmental Impact Statement (DARHT EIS) for review by the State of New Mexico, Indian Tribes, local governments, other Federal agencies, and the general public. DOE invited comments on the accuracy and adequacy of the draft EIS and any other matters pertaining to their environmental reviews. The formal comment period ran for 45 days, to June 26, 1995, although DOE indicated that late comments would be considered to the extent possible. As part of the public comment process, DOE held two public hearings in Los Alamos and Santa Fe, New Mexico, on May 31 and June 1, 1995. In addition, DOE made the draft classified supplement to the DARHT EIS available for review by appropriately cleared individuals with a need to know the classified information. Reviewers of the classified material included the State of New Mexico, the U.S. Environmental Protection Agency, the Department of Defense, and certain Indian Tribes. Volume 2 of the final DARHT EIS contains three chapters. Chapter 1 includes a collective summary of the comments received and DOE`s response. Chapter 2 contains the full text of the public comments on the draft DARHT EIS received by DOE. Chapter 3 contains DOE`s responses to the public comments and an indication as to how the comments were considered in the final EIS.

  5. Dual Axis Radiographic Hydrodynamic Test Facility mitigation action plan. Annual report for 1997

    Energy Technology Data Exchange (ETDEWEB)

    Haagenstad, H.T.

    1998-01-15

    This Mitigation Action Plan Annual Report (MAPAR) has been prepared by the US Department of Energy (DOE) as part of implementing the Dual Axis Radiographic Hydrodynamic Test Facility (DARHT) Mitigation Action Plan (MAP). This MAPAR provides a status on specific DARHT facility design- and construction-related mitigation actions that have been initiated in order to fulfill DOE`s commitments under the DARHT MAP. The functions of the DARHT MAP are to (1) document potentially adverse environmental impacts of the Phased Containment Option delineated in the Final EIS, (2) identify commitments made in the Final EIS and ROD to mitigate those potential impacts, and (3) establish Action Plans to carry out each commitment (DOE 1996). The DARHT MAP is divided into eight sections. Sections 1--5 provide background information regarding the NEPA review of the DARHT project and an introduction to the associated MAP. Section 6 references the Mitigation Action Summary Table which summaries the potential impacts and mitigation measures; indicates whether the mitigation is design-, construction-, or operational-related; the organization responsible for the mitigation measure; and the projected or actual completion data for each mitigation measure. Sections 7 and 8 discuss the Mitigation Action Plan Annual Report and Tracking System commitment and the Potential Impacts, Commitments, and Action Plans respectively. Under Section 8, potential impacts are categorized into five areas of concern: General Environment, including impacts to air and water; Soils, especially impacts affecting soil loss and contamination; Biotic Resources, especially impacts affecting threatened and endangered species; Cultural/Paleontological Resources, especially impacts affecting the archeological site known as Nake`muu; and Human Health and Safety, especially impacts pertaining to noise and radiation. Each potential impact includes a brief statement of the nature of the impact and its cause(s). The commitment

  6. Radiographic testing at Lawrence Livermore National Laboratory

    International Nuclear Information System (INIS)

    Bossi, R.H.

    1982-01-01

    Radiographic testing is a nondestructive inspection technique which uses penetrating radiation. The Nondestructive Evaluation (NDE) Section at Lawrence Livermore National Laboratory has a broad spectrum of equipment and techniques for radiographic testing. These resources include low-energy vacuum systems, low- and mid-energy cabinet and cell radiographic systems, high-energy linear accelerators, portable x-ray machines and radioisotopes for radiographic inspections. For diagnostic testing the NDE Section also has real-time and flash radiographic equipment

  7. Observer POD for radiographic testing

    Energy Technology Data Exchange (ETDEWEB)

    Kanzler, Daniel; Mueller, Christina; Bertovic, Marija [Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin (Germany); Pitkaenen, Jorma [Posiva Oy, Eurajoki (Finland)

    2013-07-01

    The radiographic testing is an important non-destructive testing method, especially in industrial areas where people could be injured in case of failing of a component. There it is a mighty method to find volumetric defects. As bigger the penetrated length of the defect in the component is, as bigger is the radiographic contrast. The detectability of volumetric defects in its turn is not only depending on the contrast but also on the noise, the defect area and its shape. The currently applied POD approach uses mostly only the contrast and the noise as detection threshold. This does not reflect accurately the results of evaluations by human observers. A new approach is introduced, using the widely applied POD evaluation and additionally a detection threshold depending on the area of the defect. The presentation shows the process of calculating the POD curves with simulated data by the modeling software aRTist and with artificial reference data. This approach was developed within a joint project with the company POSIVA, which is constructing a final depository for high active nuclear fuels in Finland. Radiographic testing is one of the NDT-methods they use to test the electron beam welds of the copper canisters. The copper canisters will be used in the depository as a corrosion barrier within the waste management concept. (Published as a poster session.)

  8. Radiographic testing

    International Nuclear Information System (INIS)

    Kuster, J.

    1978-01-01

    In view of great differencies in X-ray transmission it is more difficult to get optimum radiographs of plastics and especially of reinforced plastics than for example of metals. A procedure will be reported how to get with little effort optimum radiographs especially also in the range of long wave-length radiation corresponding 10 to 25 kV.P. (orig.) [de

  9. Radiographic testing of wood

    International Nuclear Information System (INIS)

    Osterloh, K.; Zscherpel, U.; Raedel, C.; Weidemann, G.; Meinel, D.; Goebbels, J.; Ewert, U.; Hasenstab, A.; Buecherl, T.

    2007-01-01

    Wood is an old and established consumption and construction material. It is still the most common material for constructing furniture, roofs, playgrounds and mine supports. In contrast to steel and concrete, wood warns of extreme loads by creaking. Its mechanical stability is more influenced by decay than by peripheral cracks. While external cracks are visible, internal decay by fungus growth is undetectable from outside. This may be a safety problem in supporting structures. The best analysis of the internal structure is provided by computed tomography, but this is also the most complex method, much more so than simple radiographic testing. However, the latter is made inaccurate by scattered radiation resulting from internal moisture. With the image processing options of digital radiographic techniques, the structural information can be separated effectively from noise. In contrast to X-ray and gamma radiography, neutron radiography provides information on the spatial distribution of moisture. In healthy wood, water is conducted in the sapwood while the hardwood is dry. Moisture in hardwood is caused by infestations, e.g. fungus growth. The contribution presents a comparative analysis of the available radiographic methods. (orig.)

  10. Annual Report: Hydrodynamics and Radiative Hydrodynamics with Astrophysical Applications

    Energy Technology Data Exchange (ETDEWEB)

    R. Paul Drake

    2005-12-01

    We report the ongoing work of our group in hydrodynamics and radiative hydrodynamics with astrophysical applications. During the period of the existing grant, we have carried out two types of experiments at the Omega laser. One set of experiments has studied radiatively collapsing shocks, obtaining high-quality scaling data using a backlit pinhole and obtaining the first (ever, anywhere) Thomson-scattering data from a radiative shock. Other experiments have studied the deeply nonlinear development of the Rayleigh-Taylor (RT) instability from complex initial conditions, obtaining the first (ever, anywhere) dual-axis radiographic data using backlit pinholes and ungated detectors. All these experiments have applications to astrophysics, discussed in the corresponding papers either in print or in preparation. We also have obtained preliminary radiographs of experimental targets using our x-ray source. The targets for the experiments have been assembled at Michigan, where we also prepare many of the simple components. The above activities, in addition to a variety of data analysis and design projects, provide good experience for graduate and undergraduates students. In the process of doing this research we have built a research group that uses such work to train junior scientists.

  11. Radiographic testing in concrete structures

    International Nuclear Information System (INIS)

    Oliveira, D. de

    1987-01-01

    The radiographic testing done in concrete structures is used to analyse the homogeneity, position and corrosion of armatures and to detect discontinuity in the concrete such as: gaps, cracks and segregations. This work develops a Image quality Indicator (IQI) with an adequated sensibility to detect discontinuites based on BS4408 norm. (E.G.) [pt

  12. Visual acuity testing of radiographic inspectors in nondestructive inspection. Final report

    International Nuclear Information System (INIS)

    Yonemura, G.T.

    1981-06-01

    Visual acuity tests for radiographic inspectors should be correlated with the type of tasks encountered in real world radiography. The testing procedures should be capable of assessing differences in day to day performance of a given inspector as well as the performance of one inspector relative to other inspectors. Single line targets with specific parametric values for contrast, width, and blur are recommended to provide a means for testing a radiographic inspector for visual acuity. These targets may be used for periodic tests by the employing organization or for more frequent self testing by the inspector. Statistics from the National Health Survey, procedures recommended by the NAS-NRC Committee on Vision and real world radiographs have been utilized in arriving at recommended test configurations

  13. Biodiesel production through hydrodynamic cavitation and performance testing

    Energy Technology Data Exchange (ETDEWEB)

    Pal, Amit; Verma, Ashish; Kachhwaha, S.S.; Maji, S. [Department of Mechanical Engineering, Delhi College of Engineering, Bawana Road, Delhi 110042 (India)

    2010-03-15

    This paper presents the details of development of a biodiesel production test rig based on hydrodynamic cavitation followed by results of experimental investigation carried out on a four cylinder, direct injection water cooled diesel engine operating on diesel and biodiesel blend of Citrullus colocyntis (Thumba) oil. The experiment covers a wide range of engine rpm. Results show that biodiesel of Thumba oil produced through hydrodynamic cavitation technique can be used as an alternative fuel with better performance and lower emissions compared to diesel. The most significant conclusions are that (1) Biodiesel production through hydrodynamic cavitation technique seems to be a simple, efficient, time saving, eco-friendly and industrially viable process. (2) 30% biodiesel blend of Thumba oil shows relatively higher brake power, brake thermal efficiency, reduced bsfc and smoke opacity with favourable p-{theta} diagram as compared to diesel. (author)

  14. Development of a valid and reliable test to assess trauma radiograph interpretation performance

    International Nuclear Information System (INIS)

    Neep, M.J.; Steffens, T.; Riley, V.; Eastgate, P.; McPhail, S.M.

    2017-01-01

    Objectives: The purpose of this investigation was to develop and examine the preliminary validity and reliability among radiographers of a test to assess trauma radiograph interpretation performance suitable for use among health professionals. Methods: Stage 1 examined 14,159 consecutive appendicular and axial examinations from a hospital emergency department over a 12 month period to quantify a typical anatomical region case-mix of trauma radiographs. A sample of radiographic cases representative of affected anatomical regions was then developed into the Image Interpretation Test (IIT). Stage 2 involved prospective investigations of the IIT's reliability (inter-rater, intra-rater, internal consistency) and validity (concurrent) among 41 radiographers. Results: The IIT included 60 cases. The median (interquartile range) clinical experience of participants was 5 (2–10) years. Case scores were internally consistent (Cronbach's alpha = 0.90). Favourable inter-rater reliability (kappa > 0.70 for 58/60 cases, Intra-class correlation coefficient (ICC) > 0.99 for total score) and intra-rater reliability (kappa > 0.90 for 60/60 cases, ICC > 0.99 for total score) was observed. There was a positive association between radiographers' confidence in image interpretation and IIT score (coefficient = 1.52, r-squared = 0.60, p < 0.001). Conclusions: The IIT developed during this investigation included a selection of radiographic cases consistent with anatomical regions represented in an adult trauma case-mix. This study has also provided foundational preliminary evidence to support the reliability and validity of the IIT among radiographers. The findings suggest that it is possible to assess image interpretation performance of adult trauma radiographs with this test. - Highlights: • Development of an Image Interpretation Test (IIT). • Cases consistent with anatomical regions represented in a typical adult trauma case-mix. • Development of a

  15. Relation between size of contrast meter and radiographic density difference for radiographic test aluminium welds

    International Nuclear Information System (INIS)

    Senda, Tomio; Hirayama, Kazuo; Masaoka, Naotoshi; Fujita, Minoru.

    1977-01-01

    The influence of contrast meter with difference surface area (5.0 mm x 5.0 mm, 10.0 mm x 10.0 mm, 15.0 mm x 15.0 mm, 30.0 mm x 30.0 mm) and separated type on radiographic density difference (Δ D) were investigated for radiographic test of aluminum welds. It was found that the effect of scattered radiation on contrast meter represented highest at test specimen thickness of 20 mm, and Δ D was constant as the size was increased from 10.0 mm x 10.0 mm to 15.0 mm x 15.0 mm for aluminum contrast meter. For this reason, a proposal of the contrast meter with 10.0 mm x 10.0 mm (surface area) has made to replace (15.0 mm x 15 mm) at amendment of JIS Z 3105. (auth.)

  16. Radiographic testing methods for welds of thin titanium plates and thin wall tubes

    International Nuclear Information System (INIS)

    1984-01-01

    This standard stipulates the testing method by X-ray radiography for the welded parts of titanium plates and titanium tubes with thickness not exceeding 8 mm. The other items than those stipulated here shall be in accordance with JIS Z 3107-1973 ''Testing method by radiography for the welded part of titanium and method of grade classification of radiographs''. As the photographing method of radiographs, the performance of the equipment and materials for testing, the direction of X-ray irradiation, the thickness of parent materials and welds, the use of penetrameters, the arrangement for photographing, the requirement for radiographs and the observation of radiographs are specified. The X-ray apparatuses, photo-sensitive materials and the tools for photographing and observation must be such that the radiographs clearly showing the defects in the welds being tested can be taken or observed. The JIS Z 3107 is insufficient for the test of thin materials like titanium, therefore, this standard was set down. As the thickness of welds, the thickness of parent materials was taken. In this standard, the titanium penetrameters were adopted because they can be made and they conform to practical state. If magnified photographing is carried out with microfocus X-ray apparatuses, precise photographing can be made. (Kako, I.)

  17. An Applied Image Processing for Radiographic Testing

    International Nuclear Information System (INIS)

    Ratchason, Surasak; Tuammee, Sopida; Srisroal Anusara

    2005-10-01

    An applied image processing for radiographic testing (RT) is desirable because it decreases time-consuming, decreases the cost of inspection process that need the experienced workers, and improves the inspection quality. This paper presents the primary study of image processing for RT-films that is the welding-film. The proposed approach to determine the defects on weld-images. The BMP image-files are opened and developed by computer program that using Borland C ++ . The software has five main methods that are Histogram, Contrast Enhancement, Edge Detection, Image Segmentation and Image Restoration. Each the main method has the several sub method that are the selected options. The results showed that the effective software can detect defects and the varied method suit for the different radiographic images. Furthermore, improving images are better when two methods are incorporated

  18. Concentrations of Radionuclides and Trace Elements in Environmantal Media arond te Dual-Axis Radiographic Hydrodynamic Test Facilit at Los Alamos National Laboratory during 2005

    Energy Technology Data Exchange (ETDEWEB)

    G.J.Gonzales; P.R. Fresquez; C.D.Hathcock; D.C. Keller

    2006-05-15

    The Mitigation Action Plan (MAP) for the Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility at Los Alamos National Laboratory requires that samples of biotic and abiotic media be collected after operations began to determine if there are any human health or environmental impacts. The DARHT facility is the Laboratory's principal explosive test facility. To this end, samples of soil and sediment, vegetation, bees, and birds were collected around the facility in 2005 and analyzed for concentrations of {sup 3}H, {sup 137}Cs, {sup 90}Sr, {sup 238}Pu, {sup 239,240}Pu, {sup 241}Am, {sup 234}U, {sup 235}U, {sup 238}U, Ag, As, Ba, Be, Cd, Cr, Cu, Hg, Ni, Pb, Sb, Se, and Tl. Bird populations have also been monitored. Contaminant results, which represent up to six sample years since the start of operations, were compared with (1) baseline statistical reference levels (BSRLs) established over a four-year preoperational period before DARHT facility operations, (2) screening levels (SLs), and (3) regulatory standards. Most radionuclides and trace elements were below BSRLs and those few samples that contained radionuclides and trace elements above BSRLs were below SLs. Concentrations of radionuclides and nonradionuclides in biotic and abiotic media around the DARHT facility do not pose a significant human health hazard. The total number of birds captured and number of species represented were similar in 2003 and 2004, but both of these parameters increased substantially in 2005. Periodic interruption of the scope and schedule identified in the MAP generally should have no impact on meeting the intent of the MAP. The risk of not sampling one of the five media in any given year is that if a significant impact to contaminant levels were to occur there would exist a less complete understanding of the extent of the change to the baseline for these media and to the ecosystem as a whole. Since the MAP is a requirement that was established under the regulatory framework of

  19. Radiographic test phantom for computed tomographic lung nodule analysis

    International Nuclear Information System (INIS)

    Zerhouni, E.A.

    1987-01-01

    This patent describes a method for evaluating a computed tomograph scan of a nodule in a lung of a human or non-human animal. The method comprises generating a computer tomograph of a transverse section of the animal containing lung and nodule tissue, and generating a second computer tomograph of a test phantom comprising a device which simulates the transverse section of the animal. The tissue simulating portions of the device are constructed of materials having radiographic densities substantially identical to those of the corresponding tissue in the simulated transverse section of the animal and have voids therein which simulate, in size and shape, the lung cavities in the transverse section and which contain a test reference nodule constructed of a material of predetermined radiographic density which simulates in size, shape and position within a lung cavity void of the test phantom the nodule in the transverse section of the animal and comparing the respective tomographs

  20. An apparatus to estimate the hydrodynamic coefficients of autonomous underwater vehicles using water tunnel testing.

    Science.gov (United States)

    Nouri, N M; Mostafapour, K; Bahadori, R

    2016-06-01

    Hydrodynamic coefficients or hydrodynamic derivatives of autonomous underwater vehicles (AUVs) play an important role in their development and maneuverability. The most popular way of estimating their coefficients is to implement captive model tests such as straight line tests and planar motion mechanism (PMM) tests in the towing tanks. This paper aims to develop an apparatus based on planar experiments of water tunnel in order to estimate hydrodynamic derivatives due to AUVs' acceleration and velocity. The capability of implementing straight line tests and PMM ones using mechanical oscillators located in the downstream flow of the model is considered in the design procedure of the system. The hydrodynamic derivatives that resulted from the acceleration and velocity of the AUV model were estimated using the apparatus that we developed. Static and dynamics test results were compared for the similar derivatives. The findings showed that the system provided the basis for conducting static tests, i.e., straight-line and dynamic tests that included pure pitch and pure heave. By conducting such tests in a water tunnel, we were able to eliminate errors related to the time limitation of the tests and the effects of surface waves in the towing tank on AUVs with applications in the deep sea.

  1. Radiographic testing - optimum radiographs of plastics and composite materials with dosimeter control

    International Nuclear Information System (INIS)

    Kuster, J.

    1978-01-01

    In view of great differencies in X-ray transmission it is more difficult to get optimum radiographs of plastics and especially of reinforced plastics than for example of metals. A procedure will be reported how to get with little effort optimum radiographs especially also in the range of long wavelength radiation corresponding 10 to 25 kV.P. (orig.) [de

  2. Radiographic constant exposure technique

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1985-01-01

    The constant exposure technique has been applied to assess various industrial radiographic systems. Different X-ray films and radiographic papers of two producers were compared. Special attention was given to fast film and paper used with fluorometallic screens. Radiographic image quality...... was tested by the use of ISO wire IQI's and ASTM penetrameters used on Al and Fe test plates. Relative speed and reduction of kilovoltage obtained with the constant exposure technique were calculated. The advantages of fast radiographic systems are pointed out...

  3. Radiographic and ultrasonic testings of welded joints of 6063 aluminium alloy

    International Nuclear Information System (INIS)

    Oliveira e Silva Mury, A.G. de.

    1980-05-01

    A study on evaluation of weld defects in aluminium butt joints was made in a comparative way through the radiographic and ultrasonic testing. This work was conducted with pipes 5 IPS (6,35 mm thickness) of 6063 aluminium alloy, circumferential TIG welded, due to the difficulty on performing non-destructive testing with this schedule. It was concluded thta ultrasonic testing has adequate sensitivity when setting gain adjustment is made with aid of a reference curve constructed by using a Reference Block (among others studied) with 1,5 mm dia. Hole as reference reflector, and a 5 MHz angle beam search-unit. In this case the ultrasonic testing is more accurate than radiographic testing to detect planar defects like lack of fusion and lack of penetration. Defect sizing by ultrasonic methods employed were 6 and 20 dB drop methods. In spite of your observed limitations concerning the establishment of the real size of defects, the procedure applied was precise for locate and define the weld defects that where found in this study. (author) [pt

  4. Hydrodynamic Expansion of Pellicles Caused by e-Beam Heating

    CERN Document Server

    Ho, D

    2000-01-01

    Placing a pellicle in front of a x-ray converter target for radiographic applications can confine the backstreaming ions and target plasma to a shorter channel so that the cumulative effect on e-beam focusing is reduced. The pellicle is subject to heating by e-beam since the pellicle is placed upstream of the target. The calculation of the hydrodynamic expansion, caused by the heating, using the radiation hydrodynamics code LASNEX is presented in this report. Calculations show that mylar pellicles disintegrate at the end of a multi-pulse intense e-beam while beryllium and carbon pellicles remain intact. The expansions for the kapton-carbon multi-layered targets are also examined. Hydrodynamic expansions for pellicles with various e-beam spot radii are calculated for DARHT-II beam parameters. All the simulation results indicate that the backstreaming ions can be stopped.

  5. Radiographic interpretation of the appendicular skeleton: A comparison between casualty officers, nurse practitioners and radiographers

    International Nuclear Information System (INIS)

    Coleman, Liz; Piper, Keith

    2009-01-01

    Aim: To assess how accurately and confidently casualty officers, nurse practitioners and radiographers, practicing within the emergency department (ED), recognize and describe radiographic trauma within an image test bank of 20 appendicular radiographs. Method: The participants consisted of 7 casualty officers, 13 nurse practitioners and 18 radiographers. All 20 radiographic examinations selected for the image test bank had been acquired following trauma and included some subtle, yet clinically significant abnormalities. The test bank score (maximum 40 marks), sensitivity and specificity percentages were calculated against an agreed radiological diagnosis (reference standard). Alternative Free-response Receiver Operating Characteristic (AFROC) analysis was used to assess the overall performance of the diagnostic accuracy of these professional groups. The variation in performance between each group was measured using the analysis of variance (ANOVA) test, to identify any statistical significant differences in the performance in interpretation between these groups. The relationship between the participants' perceived image interpretation accuracy during clinical practice and the actual accuracy of their image test bank score was examined using Pearson's Correlation Coefficient (r). Results: The results revealed that the radiographers gained the highest mean test bank score (28.5/40; 71%). This score was statistically higher than the mean test bank scores attained by the participating nurse practitioners (21/40; 53%) and casualty officers (21.5/40; 54%), with p < 0.01 and p = 0.02, respectively. When compared with each other, the scores from these latter groups showed no significant difference (p = 0.91). The mean 'area under the curve' (AUC) value achieved by the radiographers was also significantly higher (p < 0.01) in comparison to the AUC values demonstrated by the nurse practitioners and casualty officers, whose results, when compared, showed no significant

  6. The impact of image test bank construction on radiographic interpretation outcomes: A comparison study

    International Nuclear Information System (INIS)

    Hardy, M.; Flintham, K.; Snaith, B.; Lewis, E.F.

    2016-01-01

    Introduction: Assessment of image interpretation competency is commonly undertaken through review of a defined image test bank. Content of these image banks has been criticised for the high percentage of abnormal examinations which contrasts with lower reported incidences of abnormal radiographs in clinical practice. As a result, questions have been raised regarding the influence of prevalence bias on the accuracy of interpretive decision making. This article describes a new and novel approach to the design of musculoskeletal image test banks. Methods: Three manufactured image banks were compiled following a standard academic menu in keeping with previous studies. Three further image test banks were constructed to reflect local clinical workload within a single NHS Trust. Eighteen radiographers, blinded to the method of test bank composition, were randomly assigned 2 test banks to review (1 manufactured, 1 clinical workload). Comparison of interpretive accuracy was undertaken. Results: Inter-rater agreement was moderate to good for all image banks (manufactured: range k = 0.45–0.68; clinical workload: k = 0.49–0.62). A significant difference in mean radiographer sensitivity was noted between test bank designs (manufactured 87.1%; clinical workload 78.5%; p = 0.040, 95% CI = 0.4–16.8; t = 2.223). Relative parity in radiographer specificity and overall accuracy was observed. Conclusion: This study confirms the findings of previous research that high abnormality prevalence image banks over-estimate the ability of observers to identify abnormalities. Assessment of interpretive competency using an image bank that reflects local clinical practice is a better approach to accurately establish interpretive competency and the learning development needs of individual practitioners. - Highlights: • High prevalence image test banks over-estimate the ability of observers. • Clinical workload test banks may better reflect image interpretation competency.

  7. Fast radiographic systems

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1984-08-01

    Industrial radiography can be performed with shorter exposure times, when instead of X-ray film with lead intensifying screens the radiographic paper with fluorescent screen is used. With paper radiography one can obtain lower material, equipment, and labor costs, shorter exposure and processing times, and easier radiation protection. The speed of the radiographic inspection can also be increased by the use of fluorometallic intensifying screens together with a special brand of X-ray film. Before accepting either of the two fast radiographic systems one must be sure that they can produce radiographs of adequate image quality. Therefore an investigation was performed on that subject using ISO wire IQI's and ASTM penetrameters. The radiographic image quality was tested for aluminium and steel up to 30 mm thick using various brands of radiographic paper and X-ray film with fluorometallic screens and comparing them with fast X-ray films with lead screens. Both systems give satisfactory results. (author)

  8. Hydrodynamical tests with an original PWR heat removal pump

    International Nuclear Information System (INIS)

    Wietstock, P.

    1984-01-01

    GKSS-Forschungszentrum performes hydrodynamical tests with an original PWR heat removal pump to analyse the influences of fluid parameters on the capacity and cavitation behavior of the pump in order to get further improvements of the quantification of the reached safety-level. It can be concluded, that in case of the tested heat removal pump the additional loads during transition from cavitation free operation into fully cavitation for the investigated operation point with 980 m 3 /h will be smaller than the alteration of loads during passing through the total characteristic. The results from cavitation tests for other operation points indicate, that this very important consequence especially for accident operation will be valid for the total specified pump flow area. (orig.)

  9. Pulsed high-energy radiographic machine emitting x-rays: PHERMEX

    International Nuclear Information System (INIS)

    Dick, R.D.

    1976-01-01

    The PHERMEX facility that is used to provide radiography of explosives and explosive-driven systems is described. This facility allows precision flash radiography of large objects containing high atomic number materials. The facility consists of a high-current, three-cavity, 27-MeV linear electron accelerator; a 13.5-MW radiofrequency power source; a timing, firing, and signal detection system; and a data acquisition system. PHERMEX was built in the early part of the 1960s to complement other hydrodynamics facilities at Los Alamos and to implement studies related to shock waves, detonation, and other hydrodynamic phenomena. After 15 y of operation and several thousand explosive shots later, PHERMEX has proven to be a very important diagnostic tool in the study of hydrodynamic systems. The attractive features of PHERMEX are the following: very intense submicrosecond 27-MeV bremsstrahlung radiation; 1-mm diam spot size; 100 R at 1 m from a 200-ns pulse; precise determination of edges, discontinuities, and areal mass distribution; and flash radiographs of large explosive systems close to the target

  10. Assessment of Radiographic Image Quality by Visual Examination of Neutron Radiographs of the Calibration Fuel Pin

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    Up till now no reliable radiographic image quality standards exist for neutron radiography of nuclear reactor fuel. Under the Euratoro Neutron Radiography Working Group (NRWG) Test Program neutron radiographs were produced at different neutron radiography facilities within the European Community...... of a calibration fuel pin. The radiographs were made by the direct, transfer and tracketch methods using different film recording materials. These neutron radiographs of the calibration fuel pin were used for the assessement of radiographic image quality. This was done by visual examination of the radiographs...

  11. Study of the sensitivity of wire image quality indicators (IQI) used in radiographic testing of metals and alloys

    International Nuclear Information System (INIS)

    Sanchez, W.; Oki, H.

    1974-01-01

    Radiographic sensitivity is defined and its mathematical expresion is derived in order to justify the use of image quality indicators-IQI- formed by wires of different diameters which represent the radiographic quality. It is demonstrated that IQI sensibility is not related to the minimum dimensions of the metallic discontinuities that may be detected in radiographic tests. The experimental results are in good agreement whith the mathematical formulation proposed

  12. Annual Report 2006 for Hydrodynamics and Radiation Hydrodynamics with Astrophysical Applications

    Energy Technology Data Exchange (ETDEWEB)

    R. Paul Drake

    2007-04-05

    We report the ongoing work of our group in hydrodynamics and radiation hydrodynamics with astrophysical applications. During the period of the existing grant, we have carried out two types of experiments at the Omega laser. One set of experiments has studied radiatively collapsing shocks, obtaining data using a backlit pinhole with a 100 ps backlighter and beginning to develop the ability to look into the shock tube with optical or x-ray diagnostics. Other experiments have studied the deeply nonlinear development of the Rayleigh-Taylor (RT) instability from complex initial conditions, using dual-axis radiographic data with backlit pinholes and ungated detectors to complete the data set for a Ph.D. student. We lead a team that is developing a proposal for experiments at the National Ignition Facility and are involved in experiments at NIKE and LIL. All these experiments have applications to astrophysics, discussed in the corresponding papers. We assemble the targets for the experiments at Michigan, where we also prepare many of the simple components. We also have several projects underway in our laboratory involving our x-ray source. The above activities, in addition to a variety of data analysis and design projects, provide good experience for graduate and undergraduates students. In the process of doing this research we have built a research group that uses such work to train junior scientists.

  13. Rapidity correlations test stochastic hydrodynamics

    International Nuclear Information System (INIS)

    Zin, C; Gavin, S; Moschelli, G

    2017-01-01

    We show that measurements of the rapidity dependence of transverse momentum correlations can be used to determine the characteristic time τ π that dictates the rate of isotropization of the stress energy tensor, as well as the shear viscosity ν = η/sT . We formulate methods for computing these correlations using second order dissipative hydrodynamics with noise. Current data are consistent with τ π /ν ∼ 10 but targeted measurements can improve this precision. (paper)

  14. Potentialities of fluorography in radiographic testing of nuclear power plant equipment

    International Nuclear Information System (INIS)

    Gromov, Yu.V.; Kapustin, V.I.

    1984-01-01

    Results of fluorography of steel 5-250 mm thick with the application of different radiation sources in accordance with existing test requirements and standards for NPP equipment under industrial conditions, are presented. Sensitivity curves of fluorographic and radiographic testing methods using the RUP-150/300-10 X-ray device, LUEh-15-15000 D linear accelerator flaw detectors with 192 Yr, 60 Co, 137 Cs sources, are given. The radiation energy range is 24O keV-8 MeV. It is shown that fluorographic method meets the requirements of sensitivity and is recommended to test welded joints 5-220 mm thick in NPP equipment under laboratory and industrial conditions

  15. Rapidly processable radiographic material

    International Nuclear Information System (INIS)

    Brabandere, L.A. de; Borginon, H.A.; Pattyn, H.A.; Pollet, R.J.

    1981-01-01

    A new rapidly processable radiographic silver halide material is described for use in mammography and non-destructive testing of industrial materials. The radiographic material is used for direct exposure to penetrating radiation without the use of fluorescent-intensifying screens. It consists of a transparent support with a layer of hydrophilic colloid silver halide emulsion on one or both sides. Examples of the preparation of three different silver halide emulsions are given including the use of different chemical sensitizers. These new radiographic materials have good resistance to the formation of pressure marks in rapid processing apparatus and they have improved sensitivity for direct exposure to penetrating radiation compared to conventional radiographic emulsions. (U.K.)

  16. Annual Scientific Report 2006 for Hydrodynamics and Radiation Hydrodynamics with Astrophysical Applications

    International Nuclear Information System (INIS)

    R. Paul Drake

    2007-01-01

    We report the ongoing work of our group in hydrodynamics and radiation hydrodynamics with astrophysical applications. During the period of the existing grant, we have carried out two types of experiments at the Omega laser. One set of experiments has studied radiatively collapsing shocks, obtaining data using a backlit pinhole with a 100 ps backlighter and beginning to develop the ability to look into the shock tube with optical or x-ray diagnostics. Other experiments have studied the deeply nonlinear development of the Rayleigh-Taylor (RT) instability from complex initial conditions, using dual-axis radiographic data with backlit pinholes and ungated detectors to complete the data set for a Ph.D. student. We lead a team that is developing a proposal for experiments at the National Ignition Facility and are involved in experiments at NIKE and LIL. All these experiments have applications to astrophysics, discussed in the corresponding papers. We assemble the targets for the experiments at Michigan, where we also prepare many of the simple components. We also have several projects underway in our laboratory involving our x-ray source. The above activities, in addition to a variety of data analysis and design projects, provide good experience for graduate and undergraduates students. In the process of doing this research we have built a research group that uses such work to train junior scientists

  17. JIS Z 3105 (methods of radiographic test and classification of radiographs for aluminium welds) and its explanatory note

    International Nuclear Information System (INIS)

    Senda, Tomio

    1977-01-01

    The paragraphs of JIS Z 3105 revised in 1977 are explained, and the problems that were examined by the special committee before the JIS Z 3105 is put in force are reviewed. The JIS Z 3105 consists of a general rule, a method of radiography, a method of classification of the radiographs, and recording. The main problems which were examined are as follows: The radiation penetration testing method of a circumferencial welding portion of a tube was included in the old specifications JIS Z 3105 (1973), but it is excluded in the new specifications, because another specification JIS Z 3108 was established. The gradation meters of D1, D2, D3 and D4 types are added to the gradation meters of the existing A and B types. A restriction in accordance with both focusing dimension and thickness of the welded material is provided between a distance between the focal point and the penetrometer and a distance between the penetrometer and the film. Radiograph concentration of parts other than the penetrometer discrimination and defects of a testing part are specified in accordance with thickness of the base metal. Inclusion of copper and copper oxides are added to the blowholes, the inclusions, cracks, bad penetration and bad fusion as defects for classifying gradation. The gradation of the revised JIS is classified into four grades in lieu of the old three grades. (Iwakiri, K.)

  18. Research reactor fuel bundle design review by means of hydrodynamic testing

    International Nuclear Information System (INIS)

    Pastorini, A.; Belinco, C.

    1997-01-01

    During the design steps of a fuel bundle for a nuclear reactor, some vibration tests are usually necessary to verify the prototype dynamical response characteristics and the structural integrity. To perform these tests, the known hydrodynamic loop facilities are used to evaluate the vibrational response of the bundle under the different flow conditions that may appear in the reactor. This paper describes the tests performed on a 19 plate fuel bundle prototype designed for a low power research reactor. The tests were done in order to know the dynamical characteristics of the plates and also of the whole bundle under different flow rate conditions. The paper includes a description of the test facilities and the results obtained during the dynamical characterization tests and some preliminary comments about the tests under flowing water are also presented. (author) [es

  19. Equipment for fully automatic radiographic pipe inspection

    International Nuclear Information System (INIS)

    Basler, G.; Sperl, H.; Weinschenk, K.

    1977-01-01

    The patent describes a device for fully automatic radiographic testing of large pipes with longitudinal welds. Furthermore the invention enables automatic marking of films in radiographic inspection with regard to a ticketing of the test piece and of that part of it where testing took place. (RW) [de

  20. Radiographers and trainee radiologists reporting accident radiographs: A comparative plain film-reading performance study

    International Nuclear Information System (INIS)

    Buskov, L.; Abild, A.; Christensen, A.; Holm, O.; Hansen, C.; Christensen, H.

    2013-01-01

    Aim: To compare the diagnostic accuracy and clinical validity of reporting radiographers with that of trainee radiologists whom they have recently joined in reporting emergency room radiographs at Bispebjerg University Hospital. Materials and methods: Plain radiographs of the appendicular skeleton from 1000 consecutive emergency room patients were included in the study: 500 primarily reported by radiographers and 500 by trainee radiologists. The final reporting was subsequently undertaken by a consultant radiologist in consensus with an orthopaedic surgeon. Two observers classified reports as either true positive/negative or false positive/negative based on the final report, which was considered the reference standard. To evaluate the severity of incorrect primary reports, errors were graded into three categories concerning clinical impact and erroneous reports graded as the most severe category were subsequently analysed. Mann–Whitney and Chi-squared tests were used to compare differences and associations between radiographers versus trainee radiologists regarding film reporting. Results: The sensitivity for correct diagnosis was 99% for reporting radiographers and 94% for trainee radiologists. The specificity was found to be 97% for reporting radiographers and 99% for trainee radiologists. Radiographers missed significantly fewer fractures (n = 2) than trainee radiologists (n = 14; p = 0.006) but had a higher, but not significant, degree of overcalling. No significant difference was found between groups regarding clinical impact of incorrect reporting. Conclusion: Trained radiographers report accident radiographs of the extremities with high accuracy and constitute a qualified resource to help meet increasing workload and demands in quality standards.

  1. Thermo-hydrodynamic lubrication in hydrodynamic bearings

    CERN Document Server

    Bonneau, Dominique; Souchet, Dominique

    2014-01-01

    This Series provides the necessary elements to the development and validation of numerical prediction models for hydrodynamic bearings. This book describes the thermo-hydrodynamic and the thermo-elasto-hydrodynamic lubrication. The algorithms are methodically detailed and each section is thoroughly illustrated.

  2. Animal radiographs

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    This chapter presents historical x rays of a wide variety of animals taken within 5 years of the discovery of x radiation. Such photos were used as tests or as illustrations for radiographic publications. Numerous historical photographs are included. 10 refs

  3. Neutron radiographic testing of samples of special concrete containing recycled PET granules as aggregate

    International Nuclear Information System (INIS)

    Moraes, Antonio Carlos Alves de; Crispim, Verginia Reis

    2011-01-01

    This study aimed at inspecting microcracks in test specimens of special concrete, through neutron radiography tests. The thermal neutron flux used was extracted from the J-9 irradiation channel, placed in the thermal column of Argonauta/IEN/CNEN/RJ reactor, where a neutron radiographic system is installed. The test specimens inspected were molded in a cylindrical shape, with standard concrete and modified concrete where coarse sand was substituted by granules of recycled PET. They were submitted to compression in a SHIMADSU UH F 1000 press, causing microcracks. Then, slices of 50 μm thickness were obtained using an electrical saw. Gadolinium nitrate was used as contrast liquid in order to enhance the visualization of those microcracks. The Neutron Radiography technique proved to be appropriate for this kind of inspection, allowing to clearly visualizing the microcracks. Recycled PET granules met ABNT standards, and may be used in the construction of low income people houses, as structural concrete (25 % PP) or house floors (25% to 50% PEAD). The mechanical properties of compression and elasticity demonstrated for this special concrete, on Civil Engineering conventional tests, and by the neutron radiographic images obtained, showed that its use is viable even for civil construction in areas subject to seismic vents. (author)

  4. Computer-assisted radiographic testing for objective quality assurance of castings

    International Nuclear Information System (INIS)

    Klatte, R.

    1985-01-01

    This study is concerned with the application of digital image processing for the automatic evaluation of radiographs in material testing. It was the special aim of research to develop automatic image evaluation processes for series examination of light metal castings. The description of the problem is based on the properties of the image transmitting system Various methods for the detection of casting defects are presented and discussed. A detailed description is given of the development of a method for detecting casting defects characterized by the features of dendritic-porous-small. By generating a reference image from the test image, the method is made insensitive towards intensity fluctuations, casting tolerances and positioning errors. Then, the method was implemented into an image processing system together with the required filter (KANTROP) and the classification algorithms. The cycle times required for industrial use have also been considered. The program system for automatic testing is presented. (orig./HP) [de

  5. Inductive voltage adder advanced hydrodynamic radiographic technology demonstration

    International Nuclear Information System (INIS)

    Mazarakis, M.G.; Poukey, J.W.; Maenchen; Rovang, D.C.

    1997-04-01

    This paper presents the design, results, and analysis of a high-brightness electron beam technology demonstration experiment completed at Sandia National Laboratories, performed in collaboration with Los Alamos National Laboratory. The anticipated electron beam parameters were: 12 MeV, 35-40 kA, 0.5-mm rms radius, and 40-ns full width half maximum (FWHM) pulse duration. This beam, on an optimum thickness tantalum converter, should produce a very intense x-ray source of ∼ 1.5-mm spot size and 1 kR dose at sign 1 m. The accelerator utilized was SABRE, a pulsed inductive voltage adder, and the electron source was a magnetically immersed foilless electron diode. For these experiments, SABRE was modified to high-impedance negative-polarity operation. A new 100-ohm magnetically insulated transmission line cathode electrode was designed and constructed; the cavities were rotated 180 degrees poloidally to invert the central electrode polarity to negative; and only one of the two pulse forming lines per cavity was energized. A twenty- to thirty-Tesla solenoidal magnet insulated the diode and contained the beam at its extremely small size. These experiments were designed to demonstrate high electron currents in submillimeter radius beams resulting in a high-brightness high-intensity flash x-ray source for high-resolution thick-object hydrodynamic radiography. The SABRE facility high-impedance performance was less than what was hoped. The modifications resulted in a lower amplitude (9 MV), narrower-than-anticipated triangular voltage pulse, which limited the dose to ∼ 20% of the expected value. In addition, halo and ion-hose instabilities increased the electron beam spot size to > 1.5 mm. Subsequent, more detailed calculations explain these reduced output parameters. An accelerator designed (versus retrofit) for this purpose would provide the desired voltage and pulse shape

  6. Yield and Depth of Burial Hydrodynamic Calculations in Granodiorite: Implications for the North Korean Test Site

    Science.gov (United States)

    2011-09-01

    the existence of a test site body wave magnitude (mb) bias between U. S. and the former Soviet Union test sites in Nevada and Semipalatinsk . The use...YIELD AND DEPTH OF BURIAL HYDRODYNAMIC CALCULATIONS IN GRANODIORITE:IMPLICATIONS FOR THE NORTH KOREAN TEST SITE Esteban Rougier, Christopher R...Korean test site and the May 2009 test . When compared to the Denny and Johnson (1991) and to the Heard and Ackerman (1967) cavity radius scaling models

  7. Interpretation and digestion of radiograph

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    Radiography digestion is final test for the radiography to make sure that radiograph produced will inspect their quality of the image before its interpreted. This level is critical level where if there is a mistake, all of the radiography work done before will be unaccepted. So as mention earlier, it can waste time, cost and more worst it can make the production must shut down. So, this step, level two radiographers or interpreter must evaluate the radiograph carefully. For this purpose, digestion room and densitometer must used. Of course all the procedure must follow the specification that mentioned in document. There are several needs must fill before we can say the radiograph is corrected or not like the location of penetrameter, number of penetrameter that showed, the degree of density of film, and usually there is no problem in this step and the radiograph can go to interpretation and evaluation step as will mentioned in next chapter.

  8. Development of low-silver radiographic detectors

    International Nuclear Information System (INIS)

    Troitskij, V.A.; Novikov, I.A.; Nikitin, V.F.; Krasnyj-Admoni, L.V.; Valevich, M.I.; Belyj, N.G.; Grom, V.S.

    1988-01-01

    The results of investigations on radiographic testing of welded joints of St20, 08Kh18N10T steels, the AMG-6 alloy, copper, titanium using radiographic detectors with the low silver content are presented. The roentgenographic and photographic paper, as well as the samples of experimental films with heavy elements in the photolayer are tested using intensifying screens of different types. Experimental films containing silver 2 times as less as standard X-ray films are shown to provide the similar sensitivity of testing under equal conditions, but the exposure time is two times higher. Prints on the radiophotographic paper in quality and exposure time approach to prints obtained on the RT-1 film containing silver 10 times less than that in the roentgenographic film. The exposure time of the radiographic paper is several times less than that of the ''unibrom'' contrast paper. The testing sensitivity decreases to some extent in this case

  9. Measure by image analysis of industrial radiographs

    International Nuclear Information System (INIS)

    Brillault, B.

    1988-01-01

    A digital radiographic picture processing system for non destructive testing intends to provide the expert with computer tool, to precisely quantify radiographic images. The author describes the main problems, from the image formation to its characterization. She also insists on the necessity to define a precise process in order to automatize the system. Some examples illustrate the efficiency of digital processing for radiographic images [fr

  10. Estimation of radiation dose received by the radiation workers during radiographic testing

    International Nuclear Information System (INIS)

    Mohammed, N. A. H. O.

    2013-08-01

    This study was conducted primarily to evaluate occupational radiation dose in industrial radiography during radiographic testing at Balil-Hadida, with the aim of building up baseline data on radiation exposure in the industrial radiography practice in Sudan. Dose measurements during radiographic testing were performed and compared with IAEA reference dose. In this research the doses measured by using hand held radiation survey meter and personal monitoring dosimeter. The results showed that radiation doses ranged between minimum (0.448 mSv/ 3 month) , and maximum (1.838 mSv / 3 month), with an average value (0.778 mSv/ 3 month), and the standard deviation 0.292 for the workers used gamma mat camera. The analysis of data showed that the radiation dose for all radiation worker are receives less than annual limit for exposed workers 20 mSv/ year and compare with other study found that the dose received while body doses ranging from 0.1 to 9.4 mSv/ year, work area design in all the radiography site followed the three standard rules namely putting radiation signs, reducing access to control area and making of boundaries. Thus the accidents arising from design faults not likely to occur at these site. Results suggest that adequate fundamental training of radiation workers in general radiography prior to industrial radiography work will further improve the standard of personnel radiation protection. (Author)

  11. Radiographic evaluations

    International Nuclear Information System (INIS)

    Williams, J.L.

    1988-01-01

    The author describes how to: perform a systematic evaluation of a chest radiograph; state the classic radiographic description of hyaline membrane disease; list the conditions that cause hyperaeration and describe the radiologic feature of hyperaeration; describe the radiograph of a patient with a congenital diaphragmatic hernia; identify optimum placement of an endotracheal tube, gastric feeding tube, and umbilical artery catheter on a radiograph; differentiate between pulmonary interstitial air and hyaline membrane disease; select radiographic features that would indicate the presence of a tension pneumothorax; describe a lateral decubitus projection and state the type of problem it is most often used to identify; explain the procedure used in obtaining a lateral neck radiograph and list two problems that may require this view; and describe the radiograph of a patient with cystic fibrosis

  12. Automatic Cobb Angle Determination From Radiographic Images

    NARCIS (Netherlands)

    Sardjono, Tri Arief; Wilkinson, Michael H. F.; Veldhuizen, Albert G.; van Ooijen, Peter M. A.; Purnama, Ketut E.; Verkerke, Gijsbertus J.

    2013-01-01

    Study Design. Automatic measurement of Cobb angle in patients with scoliosis. Objective. To test the accuracy of an automatic Cobb angle determination method from frontal radiographical images. Summary of Background Data. Thirty-six frontal radiographical images of patients with scoliosis. Methods.

  13. Dynamic Stress Testing Is Unnecessary for Unimalleolar Supination-External Rotation Ankle Fractures with Minimal Fracture Displacement on Lateral Radiographs.

    Science.gov (United States)

    Nortunen, Simo; Leskelä, Hannu-Ville; Haapasalo, Heidi; Flinkkilä, Tapio; Ohtonen, Pasi; Pakarinen, Harri

    2017-03-15

    This study aimed to identify factors from standard radiographs that contributed to the stability of the ankle mortise in patients with isolated supination-external rotation fractures of the lateral malleolus (OTA/AO 44-B). Non-stress radiographs of the mortise and lateral views, without medial clear space widening or incongruity, were prospectively collected for 286 consecutive patients (mean age, 45 years [range, 16 to 85 years]), including 144 female patients (mean age, 50 years [range, 17 to 85 years]) and 142 male patients (mean age, 40 years [range, 16 to 84 years]) from 2 trauma centers. The radiographs were analyzed for fracture morphology by 2 orthopaedic surgeons, who were blinded to each other's measurements and to the results of external rotation stress radiographs (the reference for stability). Factors significantly associated with ankle mortise stability were tested in multiple logistic regression. Receiver operating characteristic analyses were performed for continuous variables to determine optimal thresholds. A sensitivity of >90% was used as the criterion for an optimal threshold. According to external rotation stress radiographs, 217 patients (75.9%) had a stable injury, defined as that with a medial clear space of ankle mortise were female sex (odds ratio [OR], 2.5 [95% confidence interval (CI), 1.4 to 4.6]), a posterior diastasis of fracture fragments (OR, 7.3 [95% CI, 2.1 to 26.3]). When the posterior diastasis was fracture fragments were present, the probability of a stable ankle mortise was 0.98 for 48 female patients (16.8%) and 0.94 for 37 male patients (12.9%). Patients with noncomminuted lateral malleolar fractures (85 patients [29.7%]) could be diagnosed with a stable ankle mortise without further stress testing, when the fracture line widths were <2 mm on lateral radiographs. Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  14. Contribution to the study for an optimum choice of filter and screens in radiographic testing

    International Nuclear Information System (INIS)

    Caillieret, V.; Peix, G.; Babot, D.; Lormand, G.

    1985-01-01

    In order to optimize the choices of screens and filter in steel specimens radiographic testing with iridium 192 and cobalt 60, we started a theoretical and experimental study of their actions on radiative and latent images formation. Theoretical modelisation of photons interactions in steel and experimental apparatus for spectral analysis are described

  15. Introduction to hydrodynamics

    International Nuclear Information System (INIS)

    Wilkins, M.L.

    1979-01-01

    Various aspects of hydrodynamics and elastic--plastic flow are introduced for the purpose of defining hydrodynamic terms and explaining what some of the important hydrodynamic concepts are. The first part covers hydrodynamic theory; and discussed fundamental hydrodynamic equations, discontinuities, and shock, detonation, and elastic--plastic waves. The second part deals with applications of hydrodynamic theory to material equations of state, spall, Taylor instabilities, and detonation pressure measurements

  16. MRI studies of the hydrodynamics in a USP 4 dissolution testing cell.

    Science.gov (United States)

    Shiko, G; Gladden, L F; Sederman, A J; Connolly, P C; Butler, J M

    2011-03-01

    We present a detailed study of hydrodynamics inside the flow-through dissolution apparatus when operated according to USP recommendations. The pulsatile flow inside the flow-through cell was measured quantitatively using magnetic resonance imaging (MRI) at a spatial resolution of 234 × 234 μm(2) and slice thickness of 1 mm. We report the experimental protocols developed for in situ MRI studies and the effect that the operating conditions and tablet orientation have on the hydrodynamics inside commercial flow cells. It was found that the flow field inside the dissolution cells was, at most operating conditions, heterogeneous, rather than fully developed laminar flow, and characterised by re-circulation and backward flow. A model tablet was shown to be contacted by a wide distribution of local velocities as a function of position and orientation in the flow cell. The use of 1 mm beads acted as a distributor of the flow but did not suffice to ensure a fully developed laminar flow profile. These results emphasise the necessity to understand the influence of test conditions on dissolution behaviour in defining robust flow-through dissolution methods. Copyright © 2010 Wiley-Liss, Inc.

  17. Radiation protection education and training of radiographers

    International Nuclear Information System (INIS)

    Elsakkers, P.

    1995-01-01

    The International Society of Radiographers and Radiological Technicians (ISRRT) is an international non-governmental organisation in official relationship with the World Health Organization. Over 50 countries are members of the ISRRT. The ISRRT encourages and facilitates communication between radiographers throughout the world. The ISRRT has produced several documents, e.g. ''The Role of the Radiographer in Europe''. The ISRRT has also done research and developed initiatives to analyse the quality of training of radiographers in the different member states of the EC. Research was done in the member states to analyse the efforts in the field of quality control. An extended study was performed on the current level of education in radiation protection in the European member states. The ICRP recommends in its publications the need of good training and continuing education for all radiographers. An important part of the basic training of radiographers should focus on the performance of radiation protection and quality control tests. Good daily practice can decrease patient dose in many ways. (Author)

  18. Radiographers and trainee radiologists reporting accident radiographs

    DEFF Research Database (Denmark)

    Buskov, L; Abild, A; Christensen, A

    2013-01-01

    To compare the diagnostic accuracy and clinical validity of reporting radiographers with that of trainee radiologists whom they have recently joined in reporting emergency room radiographs at Bispebjerg University Hospital....

  19. Final Report. Hydrodynamics by high-energy-density plasma flow and hydrodynamics and radiative hydrodynamics with astrophysical application

    International Nuclear Information System (INIS)

    R Paul Drake

    2004-01-01

    OAK-B135 This is the final report from the project Hydrodynamics by High-Energy-Density Plasma Flow and Hydrodynamics and Radiation Hydrodynamics with Astrophysical Applications. This project supported a group at the University of Michigan in the invention, design, performance, and analysis of experiments using high-energy-density research facilities. The experiments explored compressible nonlinear hydrodynamics, in particular at decelerating interfaces, and the radiation hydrodynamics of strong shock waves. It has application to supernovae, astrophysical jets, shock-cloud interactions, and radiative shock waves

  20. Study of scattering in bi-dimensional neutron radiographic images

    International Nuclear Information System (INIS)

    Oliveira, K.A.M. de; Crispim, V.R.; Silva, F.C.

    2009-01-01

    The effect of neutron scattering frequently causes distortions in neutron radiographic images and, thus, reduces the quality. In this project, a type of filter, comprised of cadmium (a neutron absorber), was used in the form of a grid to correct this effect. This device generated image data in the discrete shadow bands of the absorber, components relative to neutron scattering on the test object and surroundings. Scattering image data processing, together with the original neutron radiographic image, resulted in a corrected image with improved edge delineation and, thus, greater definition in the neutron radiographic image of the test object. The objective of this study is to propose a theoretical/experimental methodology that is capable of eliminating the components relative to neutron scattering in neutron radiographic images, coming from the material that composes the test object and the materials that compose the surrounding area. (author)

  1. Quality of radiograph

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    This chapter discussed on how to get a good radiograph. There are several factors that can make good radiograph such as density of radiograph, the contrast of radiograph, definition of radiograph, the present of artifact and backscattering. All of this factor will discuss detailed on each unit of chapter with some figure, picture to make the reader understand more when read this book. And at the end, the reader will introduce with penetrameter, one of device to determine the level of quality of the radiograph. There are two type of penetrameter like wire type or holes type. This standard must be followed by all the radiographer around the world to produce the good result that is standard and more reliable.

  2. Evaluation of the styloid process on digital panoramic radiographs

    International Nuclear Information System (INIS)

    More, Chandramani B; Asrani, Mukesh K

    2010-01-01

    The styloid process is an anatomical structure, whose clinical importance is not well understood. Proper clinical and radiographic evaluation can detect an elongated styloid process and calcification of the stylohyoid ligament. It has been reported that 2 – 28% of the general population show radiographic evidence of mineralization of a portion of the stylohyoid chain. The elongated styloid process may be symptomatic in many cases. Panoramic radiography is the best imaging modality to view the styloid process bilaterally. To assess the styloid process on digital panoramic radiographs. The study was conducted on 500 digital panoramic radiographs available in the archives of our department as soft copies. These radiographs were taken using a digital panoramic system. The radiographic length of the styloid process was measured on both sides using the measurement toolbars on the accompanying analysis software. For statistical analysis we used the unpaired t test, Chi-square test, and one-way ANOVA test, as necessary. The average length of the left styloid was 25.41 ± 6.32 mm and that of the right styloid was 25.53 ± 6.62 mm. The length of both styloids increased with age and males had longer styloids than females. Elongated styloids were present in 19.4% of the panoramic radiographs. Langlais type I elongated styloids and a partial calcification pattern were more common than others. Panoramic radiography is useful for detection of an elongated styloid process and / or ossification of the stylohyoid ligament in patients with or without symptoms, and helps avoid a misdiagnosis of tonsillar pain or pain of dental, pharyngeal, or muscular origin

  3. Assessment for hydrodynamic masses of HANARO flow tubes

    International Nuclear Information System (INIS)

    Ryu, Jeong Soo; Cho, Yeong Garp; Kim, Doo Kie; Woo, Jong Sug; Park, Jin Ho

    2000-06-01

    The effect of hydrodynamic masses is investigated in dynamic characteristics and seismic response analyses of the submerged HANARO hexagonal flow tubes. Consistent hydrodynamic masses of the surrounding water are evaluated by the prepared program using the finite element method, in which arbitrary cross-sections of submerged structures and boundary conditions of the surrounding fluid can be considered. Also lumped hydrodynamic masses are calculated using simple formula applied to hexagonal flow tubes in the infinite fluid. Modal analyses and seismic response spectrum analyses were performed using hydrodynamic masses obtained by the finite element method and the simple formula. The results of modal analysis were verified by comparing the results measured from modal tests. And the displacement results of the seismic response spectrum analysis were assessed by comparing the consistent and the lumped hydrodynamic masses obtained by various methods. Finally practical criteria based on parametric studies are proposed as the lumped hydrodynamic masses for HANARO flow tubes

  4. Assessment for hydrodynamic masses of HANARO flow tubes

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Jeong Soo; Cho, Yeong Garp; Kim, Doo Kie; Woo, Jong Sug; Park, Jin Ho

    2000-06-01

    The effect of hydrodynamic masses is investigated in dynamic characteristics and seismic response analyses of the submerged HANARO hexagonal flow tubes. Consistent hydrodynamic masses of the surrounding water are evaluated by the prepared program using the finite element method, in which arbitrary cross-sections of submerged structures and boundary conditions of the surrounding fluid can be considered. Also lumped hydrodynamic masses are calculated using simple formula applied to hexagonal flow tubes in the infinite fluid. Modal analyses and seismic response spectrum analyses were performed using hydrodynamic masses obtained by the finite element method and the simple formula. The results of modal analysis were verified by comparing the results measured from modal tests. And the displacement results of the seismic response spectrum analysis were assessed by comparing the consistent and the lumped hydrodynamic masses obtained by various methods. Finally practical criteria based on parametric studies are proposed as the lumped hydrodynamic masses for HANARO flow tubes.

  5. Radiographers' performance in chest X-ray interpretation: the Nigerian experience

    Science.gov (United States)

    Egbe, N O; Akpan, B E

    2015-01-01

    Objective: To assess the performance of Nigerian radiographers in interpretation of plain chest radiographs and to assess whether age, years since qualification and sector of practice are associated with performance. Methods: A test set of 50 radiographs containing 23 cases with no pathology (normal) and 27 abnormal cases (cardiopulmonary conditions) independently confirmed by 3 radiologists were presented to 51 radiographers in a random order. Readers independently evaluated radiographs for absence or presence of disease and stated the location, radiographic features and diagnosis. Readers self-reported their age, years since qualification and sector of practice. Receiver operating characteristic was used to assess the performance. Mann–Whitney U test was used to assess whether age, years since qualification and sector of practice were associated with performance. Results: Mean location sensitivity was 88.9 [95% confidence interval (CI), 0.787–0.980]. Mean sensitivity and specificity were 76.9 (95% CI, 0.658–0.864) and 79.8 (95% CI, 0.658–0.864), respectively. Age was not associated with performance (p = 0.07). Number of years qualified as radiographer (p = 0.005) and private practice (p = 0.004) were positively associated with performance. Conclusion: Nigerian radiographers can correctly report chest radiographs to a reasonable standard, and performance is associated with number of years since qualification and the sector of practice. Advances in knowledge: There are less than 300 radiologists serving a Nigerian population of about 170 million; therefore, X-ray interpretation by radiographers deserves consideration. Nigerian radiographers have potential to interpret chest X-ray in the clinical setting, and this may significantly improve radiology service delivery in this region. PMID:25966290

  6. Evaluation of the styloid process on digital panoramic radiographs

    Directory of Open Access Journals (Sweden)

    More Chandramani

    2010-01-01

    Full Text Available Background: The styloid process is an anatomical structure, whose clinical importance is not well understood. Proper clinical and radiographic evaluation can detect an elongated styloid process and calcification of the stylohyoid ligament. It has been reported that 2 - 28% of the general population show radiographic evidence of mineralization of a portion of the stylohyoid chain. The elongated styloid process may be symptomatic in many cases. Panoramic radiography is the best imaging modality to view the styloid process bilaterally. Aim: To assess the styloid process on digital panoramic radiographs. Materials and Methods: The study was conducted on 500 digital panoramic radiographs available in the archives of our department as soft copies. These radiographs were taken using a digital panoramic system. The radiographic length of the styloid process was measured on both sides using the measurement toolbars on the accompanying analysis software. For statistical analysis we used the unpaired t test, Chi-square test, and one-way ANOVA test, as necessary. Results: The average length of the left styloid was 25.41 ± 6.32 mm and that of the right styloid was 25.53 ± 6.62 mm. The length of both styloids increased with age and males had longer styloids than females. Elongated styloids were present in 19.4% of the panoramic radiographs. Langlais type I elongated styloids and a partial calcification pattern were more common than others. Conclusion: Panoramic radiography is useful for detection of an elongated styloid process and / or ossification of the stylohyoid ligament in patients with or without symptoms, and helps avoid a misdiagnosis of tonsillar pain or pain of dental, pharyngeal, or muscular origin.

  7. Radiographer interpretation of trauma radiographs: Issues for radiography education providers

    International Nuclear Information System (INIS)

    Hardy, Maryann; Snaith, Beverly

    2009-01-01

    Background: The role of radiographers with respect to image interpretation within clinical practice is well recognised. It is the expectation of the professional, regulatory and academic bodies that upon qualification, radiographers will possess image interpretation skills. Additionally, The College of Radiographers has asserted that its aspiration is for all radiographers to be able to provide an immediate written interpretation on skeletal trauma radiographs by 2010. This paper explores the readiness of radiography education programmes in the UK to deliver this expectation. Method: A postal questionnaire was distributed to 25 Higher Education Institutions in the UK (including Northern Ireland) that provided pre-registration radiography education as identified from the Society and College of Radiographers register. Information was sought relating to the type of image interpretation education delivered at pre- and post-registration levels; the anatomical range of image interpretation education; and education delivery styles. Results: A total of 19 responses (n = 19/25; 76.0%) were received. Image interpretation education was included as part of all radiographer pre-registration programmes and offered at post-registration level at 12 academic centres (n = 12/19; 63.2%). The anatomical areas and educational delivery methods varied across institutions. Conclusion: Radiography education providers have embraced the need for image interpretation education within both pre- and post-registration radiography programmes. As a result, UK education programmes are able to meet the 2010 College of Radiographers aspiration.

  8. Digital radiographic technology; non-destructive testing of tubine blades

    NARCIS (Netherlands)

    Penumadu, P.S.

    2014-01-01

    Inspection of turbine blades has always been a big challenge. Any irregularities in the blade have a huge impact on the gas turbine, so these blades have to be manufactured and inspected in the most sophisticated way possible. The evolution of digital radiographic technology took a leap forward to

  9. Sensitometric properties and image quality of radiographic film and paper

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1985-09-01

    When using X-ray film or radiographic paper for industrial applications one is interested in knowing not only their sensitometric properties (such as speed and contrast) but also the image quality obtainable with a particular brand of film or paper. Although standard methods for testing both properties separately are available it is desirable that the method permits the assessment of all the relevant properties together. The sensitometric properties are usually determined at constant kilovoltage and filtration at the X-ray tube, whereas radiographic image thicknesses. The use of the constant exposure technique could be used to compare both the sensitometric properties as well as the image quality for different radiographic materials. It consist of exposing different film or paper brands at a chosen, constant mAmin exposure when testing radiographic image quality for different thicknesses of a given material. From the results obtained with the constant exposure technique conclusions are drawn about its applicability as a standard method for assessing radiographic film and paper. (author)

  10. Conversion into numerical form of radiographic images

    International Nuclear Information System (INIS)

    Cappabianca, C.; Della Rocca, A.B.; Ferriani, S.

    1986-01-01

    Radiographic means are widely used for non destructive testing. However, human and technological factors strongly influence reliability of the results and further use of these technique. Image Processing can help to overtake those difficulties if radiographic films are previously digitized. This paper shows methods and equipments used in this field. The system EDI (Enea Digital. Imagery) operating in Casaccia Energy Research Centre is described

  11. Conventional frontal radiographs compared with frontal radiographs obtained from cone beam computed tomography.

    Science.gov (United States)

    Nur, Metin; Kayipmaz, Saadettin; Bayram, Mehmet; Celikoglu, Mevlut; Kilkis, Dogan; Sezgin, Omer Said

    2012-07-01

    To test the hypothesis that there is no difference between measurements performed on conventional frontal radiographs (FRs) and those performed on FRs obtained from cone beam computed tomography (CBCT) scans. This study consisted of conventional FRs and CBCT-constructed FRs obtained from 30 young adult patients. Twenty-three landmarks were identified on both types of cephalometric radiographs. Twenty-one widely used cephalometric variables (14 linear distances, 4 angles, and 3 ratios) were calculated. Paired t-tests were performed to compare the means of corresponding measurements on two cephalometric radiographs of the same patient. Reproducibility of measurements ranged from 0.85 to 0.99 for CBCT-constructed FRs, and from 0.78 to 0.96 for conventional FRs. A statistically significant difference was observed between conventional FRs and CBCT-constructed FRs for all linear measurements (eurR-eurL, loR-loL, moR-moL, zygR-zygL, lapR-lapL, mxR-mxL, maR-maL, umR-umL, lmR-lmL, agR-agL, me-ans) (P .05). However, no statistically significant differences were noted between conventional FRs and CBCT-constructed FRs for ratios and angular measurements (P > .05). The hypothesis was rejected. A difference has been noted between measurements performed on conventional FRs and those performed on CBCT-constructed FRs, particularly in terms of linear measurements.

  12. Evaluation of underexposed conventional radiographs after digitization

    International Nuclear Information System (INIS)

    Wenz, W.

    1993-01-01

    Inadequate exposure of analogue radiographs is reported in the literature to occur in 5-25% of cases. Therefore, the present study was performed to test whether selective image processing after digitization could reveal diagnostic details on underexposed radiographs. In addition, the minimal exposure values required for diagnostic purposes after adequate image processing were studied. Phantom studies, organ preparations and measurements of physical parameters with decreasing exposure values were performed. The detection of anatomic and pathologic (nondisplaced fracture lines, microcalcification and renal stones) structures were evaluated by 12 readers. Radiographs with exposure values 20-40% lower than 'ideal' values can provide adequate diagnostic images after digital processing. The diagnostic information is significantly impaired with values under 50% of the correct exposure values. In conclusion, this method is adequate to save underexposed radiographs for diagnostic purposes and to avoid repeated examinations. (orig.) [de

  13. Radiographic and tomographic study of the elbow joint in dogs

    International Nuclear Information System (INIS)

    Sendyk-Grunkraut, Alessandra; Martin, Claudia M.; Souza, Alexandre N.A.; Patricio, Geni Cristina F.; Lorigados, Carla A.B.; Matera, Julia M.; Fonseca-Pinto, Ana C.B.C.

    2017-01-01

    Elbow dysplasia disease includes an united anconeal process, fragmented medial coronoid process, osteochondrosis of humeral trochlea, articular incongruity and degenerative joint disease. The aim of this study was to present detailed morphologic and morphometric aspects of the elbow joint in dog in clinical and correlate with radiographic and tomographic (CT) exam. Inter-observer variation for articular incongruity measurements by CT, comparative analysis in the radiographic exam, angle in ulnar notch and its comparative analysis between radiographic and tomographic agreement examination in 44 elbow of dogs with different ages were evaluated. The statistics analyses included the kappa coefficient and interclass correlation and Fischer's test and McNemar's test. It was evidenced that individual performance of each radiographic incidence had poor agreement with the tomographic exam, suggesting that the accomplishment of more than two radiograph views are needed. There was no agreement between the three evaluators in the ulnar notch angle at radiographic and tomographic exams. However, there was good/moderate agreement for articular incongruity measurement in the sagittal plane between evaluators. It was possible to conclude that none of the five radiographic incidences was better than the others for radiographic analysis because each incidence had a better identification of a particular elbow compartment; measurements at the tomographic exam to evaluate radioulnar incongruity had no reproductiveness in the frontal plane, but in sagittal plan had a good/moderate agreement between observers and the angle in ulnar notch presented no repeatability at radiographic exam and no reproductiveness at tomographic exam. (author)

  14. Report on the behalf of the Foreign Affairs, Defence and Armed Forces Commission on the bill project authorizing the ratification of the treaty between the French Republic, the United-Kingdom of Great-Britain and Northern Ireland related to common hydrodynamic and radiographic installations

    International Nuclear Information System (INIS)

    Pintat, X.

    2011-01-01

    After a presentation of the main directions defined during the London summit for the French-British defence cooperation (convergence of interests and ambitions, cooperation in the operational, capacity, technological and industrial areas), this report more precisely presents and discusses the cooperation perspectives in the military nuclear field (deterrence by the French and British nuclear weapons, the experimentation as a field of cooperation, cooperation modalities with a common installation and a common technological development centre). These perspectives encompass experimentation installations aimed at the simulation of nuclear weapons. Then, it details the content of the treaty related to common hydrodynamic and radiographic installations: characteristics of the EPURE and TDC installations, financing conditions, and some other issues

  15. Minimum joint space width (mJSW) of patellofemoral joint on standing ''skyline'' radiographs: test-retest reproducibility and comparison with quantitative magnetic resonance imaging (qMRI)

    International Nuclear Information System (INIS)

    Simoni, Paolo; Jamali, Sanaa; Alvarez Miezentseva, Victoria; Albert, Adelin; Totterman, Saara; Schreyer, Edward; Tamez-Pena, Jose G.; Zobel, Bruno Beomonte; Gillet, Philippe

    2013-01-01

    To assess the intraobserver, interobserver, and test-retest reproducibility of minimum joint space width (mJSW) measurement of medial and lateral patellofemoral joints on standing ''skyline'' radiographs and to compare the mJSW of the patellofemoral joint to the mean cartilage thickness calculated by quantitative magnetic resonance imaging (qMRI). A couple of standing ''skyline'' radiographs of the patellofemoral joints and MRI of 55 knees of 28 volunteers (18 females, ten males, mean age, 48.5 ± 16.2 years) were obtained on the same day. The mJSW of the patellofemoral joint was manually measured and Kellgren and Lawrence grade (KLG) was independently assessed by two observers. The mJSW was compared to the mean cartilage thickness of patellofemoral joint calculated by qMRI. mJSW of the medial and lateral patellofemoral joint showed an excellent intraobserver agreement (interclass correlation (ICC) = 0.94 and 0.96), interobserver agreement (ICC = 0.90 and 0.95) and test-retest agreement (ICC = 0.92 and 0.96). The mJSW measured on radiographs was correlated to mean cartilage thickness calculated by qMRI (r = 0.71, p < 0.0001 for the medial PFJ and r = 0.81, p < 0.0001 for the lateral PFJ). However, there was a lack of concordance between radiographs and qMRI for extreme values of joint width and KLG. Radiographs yielded higher joint space measures than qMRI in knees with a normal joint space, while qMRI yielded higher joint space measures than radiographs in knees with joint space narrowing and higher KLG. Standing ''skyline'' radiographs are a reproducible tool for measuring the mJSW of the patellofemoral joint. The mJSW of the patellofemoral joint on radiographs are correlated with, but not concordant with, qMRI measurements. (orig.)

  16. Digital interactive learning of oral radiographic anatomy.

    Science.gov (United States)

    Vuchkova, J; Maybury, T; Farah, C S

    2012-02-01

    Studies reporting high number of diagnostic errors made from radiographs suggest the need to improve the learning of radiographic interpretation in the dental curriculum. Given studies that show student preference for computer-assisted or digital technologies, the purpose of this study was to develop an interactive digital tool and to determine whether it was more successful than a conventional radiology textbook in assisting dental students with the learning of radiographic anatomy. Eighty-eight dental students underwent a learning phase of radiographic anatomy using an interactive digital tool alongside a conventional radiology textbook. The success of the digital tool, when compared to the textbook, was assessed by quantitative means using a radiographic interpretation test and by qualitative means using a structured Likert scale survey, asking students to evaluate their own learning outcomes from the digital tool. Student evaluations of the digital tool showed that almost all participants (95%) indicated that the tool positively enhanced their learning of radiographic anatomy and interpretation. The success of the digital tool in assisting the learning of radiographic interpretation is discussed in the broader context of learning and teaching curricula, and preference (by students) for the use of this digital form when compared to the conventional literate form of the textbook. Whilst traditional textbooks are still valued in the dental curriculum, it is evident that the preference for computer-assisted learning of oral radiographic anatomy enhances the learning experience by enabling students to interact and better engage with the course material. © 2011 John Wiley & Sons A/S.

  17. The radiographic acromiohumeral interval is affected by arm and radiographic beam position

    Energy Technology Data Exchange (ETDEWEB)

    Fehringer, Edward V.; Rosipal, Charles E.; Rhodes, David A.; Lauder, Anthony J.; Feschuk, Connie A.; Mormino, Matthew A.; Hartigan, David E. [University of Nebraska Medical Center, Department of Orthopaedic Surgery and Rehabilitation, Omaha, NE (United States); Puumala, Susan E. [Nebraska Medical Center, Department of Preventive and Societal Medicine, Omaha, NE (United States)

    2008-06-15

    The objective was to determine whether arm and radiographic beam positional changes affect the acromiohumeral interval (AHI) in radiographs of healthy shoulders. Controlling for participant's height and position as well as radiographic beam height and angle, from 30 right shoulders of right-handed males without shoulder problems four antero-posterior (AP) radiographic views each were obtained in defined positions. Three independent, blinded physicians measured the AHI to the nearest millimeter in 120 randomized radiographs. Mean differences between measurements were calculated, along with a 95% confidence interval. Controlling for observer effect, there was a significant difference between AHI measurements on different views (p<0.01). All pair-wise differences were statistically significant after adjusting for multiple comparisons (all p values <0.01). Even in healthy shoulders, small changes in arm position and radiographic beam orientation affect the AHI in radiographs. (orig.)

  18. Estimated accuracy of classification of defects detected in welded joints by radiographic tests

    International Nuclear Information System (INIS)

    Siqueira, M.H.S.; De Silva, R.R.; De Souza, M.P.V.; Rebello, J.M.A.; Caloba, L.P.; Mery, D.

    2004-01-01

    This work is a study to estimate the accuracy of classification of the main classes of weld defects detected by radiography test, such as: undercut, lack of penetration, porosity, slag inclusion, crack or lack of fusion. To carry out this work non-linear pattern classifiers were developed, using neural networks, and the largest number of radiographic patterns as possible was used as well as statistical inference techniques of random selection of samples with and without repositioning (bootstrap) in order to estimate the accuracy of the classification. The results pointed to an estimated accuracy of around 80% for the classes of defects analyzed. (author)

  19. Estimated accuracy of classification of defects detected in welded joints by radiographic tests

    Energy Technology Data Exchange (ETDEWEB)

    Siqueira, M.H.S.; De Silva, R.R.; De Souza, M.P.V.; Rebello, J.M.A. [Federal Univ. of Rio de Janeiro, Dept., of Metallurgical and Materials Engineering, Rio de Janeiro (Brazil); Caloba, L.P. [Federal Univ. of Rio de Janeiro, Dept., of Electrical Engineering, Rio de Janeiro (Brazil); Mery, D. [Pontificia Unversidad Catolica de Chile, Escuela de Ingenieria - DCC, Dept. de Ciencia de la Computacion, Casilla, Santiago (Chile)

    2004-07-01

    This work is a study to estimate the accuracy of classification of the main classes of weld defects detected by radiography test, such as: undercut, lack of penetration, porosity, slag inclusion, crack or lack of fusion. To carry out this work non-linear pattern classifiers were developed, using neural networks, and the largest number of radiographic patterns as possible was used as well as statistical inference techniques of random selection of samples with and without repositioning (bootstrap) in order to estimate the accuracy of the classification. The results pointed to an estimated accuracy of around 80% for the classes of defects analyzed. (author)

  20. Utilization of radiographic and ultrasonic testing for an evaluation of plate type fuel elements during manufacturing stages

    International Nuclear Information System (INIS)

    Brito, Mucio Jose Drummond de; Silva Junior, Silverio Ferreira da; Messias, Jose Marcos; Braga, Daniel Martins; Paula, Joao Bosco de

    2005-01-01

    Structural discontinuities can be introduced in the plate type fuel elements during the manufacturing stages due to mechanical processing conditions. The use of nondestructive testing methods to monitoring the fuel elements during the manufacturing stages presents a significant importance, contributing for manufacturing process improvement and cost reducing. This paper describes a procedure to be used detection and evaluation of structural discontinuities in plate type fuel elements during the manufacturing stages using the ultrasonic testing method and the radiographic testing method. The main results obtained are presented and discussed. (author)

  1. Radiographic imaging. 4 ed.

    International Nuclear Information System (INIS)

    Chesney, D.N.; Chesney, M.O.

    1981-01-01

    This is a revised edition of the textbook previously entitled 'Radiographic Photography' and accords with the current syllabus of training for the Diploma of the Royal College of Radiographers. The aim is a non-mathematical approach to provide a guide for the student to the knowledge and understanding of the theoretical concepts which affect the quality of radiographic image; materials and practices are also reviewed, particularly in relation to the characteristics of the radiographic image, and to processing equipment and processing areas. The subject is dealt with under the following headings: the photographic process, film materials in x-ray departments, sensitometry, storage of film materials and radiographs, intensifying screens and cassettes, film processing, developing, fixing, rinsing, washing, drying, the processing area and equipment, systems for daylight film handling, the radiographic image, management of the quality, presentation of the radiograph, light images and their recording, fluorography, some special imaging processes, e.g. xerography, copying radiographs. (U.K.)

  2. A contribution to quality control in veterinary radiology. Development and calibration of a test-phantom for the control of the picture quality of radiographs of the abdomen of the cat

    International Nuclear Information System (INIS)

    Mueller-Wabro, A.

    1996-10-01

    The theme of this thesis was the extension of the application of a test phantom developed at the institute of medical physics (University of Veterinary Medicine/Vienna) and the calibration for the abdomen of the cat. The test phantom is a stepped test body consisting of a material, which absorbs and scatters X-rays similar to bony tissue. On the baseplate of the staircase there are holes 0.5 and 0.7 mm in diameter. Objective parameters of a radiograph - radiographic density latitude, contrast and detail visibility - can be examined with the phantom. By using subjective 'good' rated radiographs it was possible to establish an indirect relation between the soft tissue of the abdomen and the phantom by comparing the optical density. Thus the practicability of the application for abdominal radiographs could be demonstrated. The recognizability of the holes means a measure of detail visibility. For the represented parameters of an X-ray picture are connected, one can conclude radiograph quality from detail visibility. On the basis of the results of a judgement by test-persons a nomogram was designed, which is of use in quick classifying and controlling X-ray pictures. (author)

  3. Internet-accessible radiographic database of Vietnam War casualties for medical student education.

    Science.gov (United States)

    Critchley, Eric P; Smirniotopoulos, James G

    2003-04-01

    The purpose of this study was to determine the feasibility of archiving radiographic images from Vietnam era conflict casualties into a personal computer-based electronic database of text and images and displaying the data using an Internet-accessible database for preservation and educational purposes. Thirty-two patient cases were selected at random from a pool of 1,000 autopsy reports in which radiographs were available. A total of 74 radiographs from these cases were digitized using a commercial image scanner and then uploaded into an Internet accessible database. The quality of the digitized images was assessed by administering an image-based test to a group of 12 medical students. No statistically significant (p > 0.05) differences were found between test scores when using the original radiographs versus using the digitized radiographs on the Internet-accessible database. An Internet-accessible database is capable of effectively archiving Vietnam era casualty radiographs for educational purposes.

  4. Numerical Hydrodynamics in Special Relativity.

    Science.gov (United States)

    Martí, José Maria; Müller, Ewald

    2003-01-01

    This review is concerned with a discussion of numerical methods for the solution of the equations of special relativistic hydrodynamics (SRHD). Particular emphasis is put on a comprehensive review of the application of high-resolution shock-capturing methods in SRHD. Results of a set of demanding test bench simulations obtained with different numerical SRHD methods are compared. Three applications (astrophysical jets, gamma-ray bursts and heavy ion collisions) of relativistic flows are discussed. An evaluation of various SRHD methods is presented, and future developments in SRHD are analyzed involving extension to general relativistic hydrodynamics and relativistic magneto-hydrodynamics. The review further provides FORTRAN programs to compute the exact solution of a 1D relativistic Riemann problem with zero and nonzero tangential velocities, and to simulate 1D relativistic flows in Cartesian Eulerian coordinates using the exact SRHD Riemann solver and PPM reconstruction. Supplementary material is available for this article at 10.12942/lrr-2003-7 and is accessible for authorized users.

  5. Australian rural radiographers' perspectives on disclosure of their radiographic opinion to patients

    International Nuclear Information System (INIS)

    Squibb, Kathryn; Bull, Rosalind M.; Smith, Anthony; Dalton, Lisa

    2015-01-01

    The role of Australian rural radiographers in radiographic interpretation, communication and disclosure of their radiographic opinion with a specific focus on plain film radiography was examined in a two phase, exploratory interpretive study. Data were collected using questionnaires and interviews and analysed thematically. This reports one of the key themes identified in the thematic data analysis. ‘Disclosure of Radiographic Opinion to Patients’ comprises the three interrelated sub-themes Acting Ethically, Selective Disclosure and Filtered Truth. It is wholly concerned with the ways in which rural radiographers choose to disclose their radiographic opinion to patients. Without a clear picture of where they stand medico-legally, rural radiographers draw on experience and a strong ethical framework as the basis for these complex decisions. Rural radiographers frame their disclosures to patients in a manner that is governed by the diagnostic, therapeutic and emotional impact the information disclosed may have on the patient. Disclosure to patients was found to be selective, often diagnostically vague and ethically filtered

  6. Elasto-hydrodynamic lubrication

    CERN Document Server

    Dowson, D; Hopkins, D W

    1977-01-01

    Elasto-Hydrodynamic Lubrication deals with the mechanism of elasto-hydrodynamic lubrication, that is, the lubrication regime in operation over the small areas where machine components are in nominal point or line contact. The lubrication of rigid contacts is discussed, along with the effects of high pressure on the lubricant and bounding solids. The governing equations for the solution of elasto-hydrodynamic problems are presented.Comprised of 13 chapters, this volume begins with an overview of elasto-hydrodynamic lubrication and representation of contacts by cylinders, followed by a discussio

  7. Elementary classical hydrodynamics

    CERN Document Server

    Chirgwin, B H; Langford, W J; Maxwell, E A; Plumpton, C

    1967-01-01

    Elementary Classical Hydrodynamics deals with the fundamental principles of elementary classical hydrodynamics, with emphasis on the mechanics of inviscid fluids. Topics covered by this book include direct use of the equations of hydrodynamics, potential flows, two-dimensional fluid motion, waves in liquids, and compressible flows. Some general theorems such as Bernoulli's equation are also considered. This book is comprised of six chapters and begins by introducing the reader to the fundamental principles of fluid hydrodynamics, with emphasis on ways of studying the motion of a fluid. Basic c

  8. Appearance of the weight-bearing lateral radiograph in retrocalcaneal bursitis

    Science.gov (United States)

    Muller, Bart; Maas, Mario; Sierevelt, Inger N; van Dijk, C Niek

    2010-01-01

    Background and purpose A retrocalcaneal bursitis is caused by repetitive impingement of the bursa between the Achilles tendon and the posterosuperior calcaneus. The bursa is situated in the posteroinferior corner of Kager's triangle (retrocalcaneal recess), which is a radiolucency with sharp borders on the lateral radiograph of the ankle. If there is inflammation, the fluid-filled bursa is less radiolucent, making it difficult to delineate the retrocalcaneal recess. We assessed whether the radiographic appearance of the retrocalcaneal recess on plain digital (filmless) radiographs could be used in the diagnosis of a retrocalcaneal bursitis. Methods Whether or not there was obliteration of the retrocalcaneal recess (yes/no) on 74 digital weight-bearing lateral radiographs of the ankle was independently assessed by 2 observers. The radiographs were from 24 patients (25 heels) with retrocalcaneal bursitis (confirmed on endoscopic calcaneoplasty); the control group consisted of 50 patients (59 heels). Results The sensitivity of the test was 83% for observer 1 and 79% for observer 2. Specificity was 100% and 98%, respectively. The kappa value of the interobserver reliability test was 0.86. For observer 1, intraobserver reliability was 0.96 and for observer 2 it was 0.92. Interpretation On digital weight-bearing lateral radiographs of a retrocalcaneal bursitis, the retrocalcaneal recess has a typical appearance. PMID:20450438

  9. Coupled hydrodynamic-structural analysis of an integral flowing sodium test loop in the TREAT reactor

    International Nuclear Information System (INIS)

    Zeuch, W.R.; A-Moneim, M.T.

    1979-01-01

    A hydrodynamic-structural response analysis of the Mark-IICB loop was performed for the TREAT (Transient Reactor Test Facility) test AX-1. Test AX-1 is intended to provide information concerning the potential for a vapor explosion in an advanced-fueled LMFBR. The test will be conducted in TREAT with unirradiated uranium-carbide fuel pins in the Mark-IICB integral flowing sodium loop. Our analysis addressed the ability of the experimental hardware to maintain its containment integrity during the reference accident postulated for the test. Based on a thermal-hydraulics analysis and assumptions for fuel-coolant interaction in the test section, a pressure pulse of 144 MPa maximum pressure and pulse width of 1.32 ms has been calculated as the reference accident. The response of the test loop to the pressure transient was obtained with the ICEPEL and STRAW codes. Modelling of the test section was completed with STRAW and the remainder of the loop was modelled by ICEPEL

  10. Development and testing of texture discriminators for the analysis of trabecular bone in proximal femur radiographs

    International Nuclear Information System (INIS)

    Huber, M. B.; Carballido-Gamio, J.; Fritscher, K.; Schubert, R.; Haenni, M.; Hengg, C.; Majumdar, S.; Link, T. M.

    2009-01-01

    Purpose: Texture analysis of femur radiographs may serve as a potential low cost technique to predict osteoporotic fracture risk and has received considerable attention in the past years. A further application of this technique may be the measurement of the quality of specific bone compartments to provide useful information for treatment of bone fractures. Two challenges of texture analysis are the selection of the best suitable texture measure and reproducible placement of regions of interest (ROIs). The goal of this in vitro study was to automatically place ROIs in radiographs of proximal femur specimens and to calculate correlations between various different texture analysis methods and the femurs' anchorage strength. Methods: Radiographs were obtained from 14 femoral specimens and bone mineral density (BMD) was measured in the femoral neck. Biomechanical testing was performed to assess the anchorage strength in terms of failure load, breakaway torque, and number of cycles. Images were segmented using a framework that is based on the usage of level sets and statistical in-shape models. Five ROIs were automatically placed in the head, upper and lower neck, trochanteric, and shaft compartment in an atlas subject. All other subjects were registered rigidly, affinely, and nonlinearly, and the resulting transformation was used to map the five ROIs onto the individual femora. Results: In each ROI, texture features were extracted using gray level co-occurence matrices (GLCM), third-order GLCM, morphological gradients (MGs), Minkowski dimensions (MDs), Minkowski functionals (MFs), Gaussian Markov random fields, and scaling index method (SIM). Coefficients of determination for each texture feature with parameters of anchorage strength were computed. In a stepwise multiregression analysis, the most predictive parameters were identified in different models. Texture features were highly correlated with anchorage strength estimated by the failure load of up to R 2 =0.61 (MF

  11. A radiographic study of mental foramen in intraoral radiographs

    International Nuclear Information System (INIS)

    Sohn, Jeong Ick; Choi, Karp Shik

    1995-01-01

    The purpose of this study was to evaluate the position and shape of mental foramen in periapical radiographs. For this study, periapical radiographs of premolar areas were obtained from the 200 adults. Accordingly, the positional and shape changes of mental foramen were evaluated. The authors obtained radiographs according to changes in radiation beam direction in periapical radiographs of premolar areas, and then evaluated the positional and shape changes of mental foramen. The following results were obtained: 1. Shapes of mental foramen were observed elliptical (34.3%), round or oval (28.0%), unidentified (25.5%) and diffuse (12.2%) type in descending order of frequency. 2, Horizontal positions of mental foramen were most frequently observed at the 2nd premolar area (55.3%), the area between the 1st premolar and 2nd premolar (39.6%), the area between the 2nd premolar and 1st molar (3.4%), the 1st premolar area (1.0%), the area between the canine and 1st premolar (0.7%) in descending order of frequency. 3. Vertical positions of mental foramen were most frequently observed at the inferior to apex (67.1%), and at apex (24.8%), overlap with apex (6.4%), superior to apex (1.7%) in descending order of frequency. 4. Shapes of mental foramen were more obviously observed at the upward 10 degree positioned periapical radiographs. And according to the changes of horizontal and vertical position, they were observed similar to normally positioned periapical radiographs.

  12. Advanced radiographic scanning, enhancement and electronic data storage

    International Nuclear Information System (INIS)

    Savoie, C.; Rivest, D.

    2003-01-01

    It is a well-known fact that radiographs deteriorate with time. Substantial cost is attributed to cataloguing and storage. To eliminate deterioration issues and save time retrieving radiographs, laser scanning techniques were developed in conjunction with viewing and enhancement software. This will allow radiographs to be successfully scanned and stored electronically for future reference. Todays radiographic laser scanners are capable Qf capturing images with an optical density of up to 4.1 at 256 grey levels and resolutions up to 4096 pixels per line. An industrial software interface was developed for the nondestructive testing industry so that, certain parameters such as scan resolution, number of scans, file format and location to be saved could be adjusted as needed. Once the radiographs have been scanned, the tiff images are stored, or retrieved into Radiance software (developed by Rivest Technologies Inc.), which will help to properly interpret the radiographs. Radiance was developed to allow the user to quickly view the radiographs correctness or enhance its defects for comparison and future evaluation. Radiance also allows the user to zoom, measure and annotate areas of interest. Physical cost associated with cataloguing, storing and retrieving radiographs can be eliminated. You can now successfully retrieve and view your radiographs from CD media or dedicated hard drive at will. For continuous searches and/or field access, dedicated hard drives controlled by a server would be the media of choice. All scanned radiographs will be archived to CD media (CD-R). Laser scanning with a proper acquisition interface and easy to use viewing software will permit a qualified user to identify areas of interest and share this information with his/her colleagues via e-mail or web data access. (author)

  13. Shock-hydrodynamics experiments on the Nova laser

    International Nuclear Information System (INIS)

    Miller, P.; Peyser, T.; Stry, P.; Budil, K.; Wojtowicz, D.; Burke, E.

    1995-08-01

    We have conducted shock-induced hydrodynamics experiments using the Nova laser at Lawrence Livermore National Laboratory. The laser provides a high-enthalpy source by depositing its energy (about 22 kJ) in a small gold cavity called a Hohlraum. The Hohlraum serves as a driver section, launching very strong (M ∼ 20) shocks into millimeter-scale cylindrical ''shock tubes.'' The flow is imaged radiographically by an electronic framing camera, using a laser-generated x-ray source. Several topics have been addressed with this configuration, including shock-induced mixing at density interfaces (seeded with a variety of perturbations); the development of high-speed, shaped-charge-like jets; the effects of geometry on the planarity of the generated shocks; and shock-shock interactions which develop in the flows. This paper describes the general configuration of our experiments, presents an overview of the high-speed jet work, discusses some of our findings, and compares our results with computer simulations

  14. Conditional non-independence of radiographic image features and the derivation of post-test probabilities – A mammography BI-RADS example

    International Nuclear Information System (INIS)

    Benndorf, Matthias

    2012-01-01

    Bayes' theorem has proven to be one of the cornerstones in medical decision making. It allows for the derivation of post-test probabilities, which in case of a positive test result become positive predictive values. If several test results are observed successively Bayes' theorem may be used with assumed conditional independence of test results or with incorporated conditional dependencies. Herein it is examined whether radiographic image features should be considered conditionally independent diagnostic tests when post-test probabilities are to be derived. For this purpose the mammographic mass dataset from the UCI (University of California, Irvine) machine learning repository is analysed. It comprises the description of 961 (516 benign, 445 malignant) mammographic mass lesions according to the BI-RADS (Breast Imaging: Reporting and Data System) lexicon. Firstly, an exhaustive correlation matrix is presented for mammography BI-RADS features among benign and malignant lesions separately; correlation can be regarded as measure for conditional dependence. Secondly, it is shown that the derived positive predictive values for the conjunction of the two features “irregular shape” and “spiculated margin” differ significantly depending on whether conditional dependencies are incorporated into the decision process or not. It is concluded that radiographic image features should not generally be regarded as conditionally independent diagnostic tests.

  15. Comparison between sodium hypochlorite and copper sulfate reducer in lightening of overexposed working length radiographs

    Directory of Open Access Journals (Sweden)

    Fatemeh Ezoddini Ardakani

    2015-12-01

    Full Text Available Objectives: The aims of this study were to test whether lightening of the overexposed radiographs improve determination of endodontic files length and whether lightened radiographs are comparable with ideally exposed radiographs. Material and Methods: Four dried human skull coated with soft tissue-equivalent wax used for exposing radiographs of the upper molars. First, the endodontic file was placed in full length of the root and four series of radiographs obtained. The time to expose the first series was unchanged (standard group but increased for the other three series.  Two series of overexposed radiographs set as test groups (one lightened with copper sulfate reducer and the other lightened with sodium hypochlorite and one series set as control group. Then the endodontic file placed 2mm short in the root and four series of radiographs obtained like the former. A viewer evaluated radiographs. ROC curves were obtained and areas under the curves were calculated. Sensitivity, specificity and Cohen’s kappa was calculated. Results: The average area under ROC curves was 1, 0.995,1 and 0.643 for the standard, Copper sulfate, sodium hypochlorite and the control group, respectively. Sodium hypochlorite show a better performance in terms of sensitivity and specificity compared to Copper sulfate. Differences between the test radiographs and standard and control radiographs were significant (p

  16. Entropy-limited hydrodynamics: a novel approach to relativistic hydrodynamics

    Science.gov (United States)

    Guercilena, Federico; Radice, David; Rezzolla, Luciano

    2017-07-01

    We present entropy-limited hydrodynamics (ELH): a new approach for the computation of numerical fluxes arising in the discretization of hyperbolic equations in conservation form. ELH is based on the hybridisation of an unfiltered high-order scheme with the first-order Lax-Friedrichs method. The activation of the low-order part of the scheme is driven by a measure of the locally generated entropy inspired by the artificial-viscosity method proposed by Guermond et al. (J. Comput. Phys. 230(11):4248-4267, 2011, doi: 10.1016/j.jcp.2010.11.043). Here, we present ELH in the context of high-order finite-differencing methods and of the equations of general-relativistic hydrodynamics. We study the performance of ELH in a series of classical astrophysical tests in general relativity involving isolated, rotating and nonrotating neutron stars, and including a case of gravitational collapse to black hole. We present a detailed comparison of ELH with the fifth-order monotonicity preserving method MP5 (Suresh and Huynh in J. Comput. Phys. 136(1):83-99, 1997, doi: 10.1006/jcph.1997.5745), one of the most common high-order schemes currently employed in numerical-relativity simulations. We find that ELH achieves comparable and, in many of the cases studied here, better accuracy than more traditional methods at a fraction of the computational cost (up to {˜}50% speedup). Given its accuracy and its simplicity of implementation, ELH is a promising framework for the development of new special- and general-relativistic hydrodynamics codes well adapted for massively parallel supercomputers.

  17. Investigation of the hydrodynamic model test of forced rolling for a barge using PIV

    Directory of Open Access Journals (Sweden)

    WANG Xiaoqiang

    2017-03-01

    Full Text Available In order to study the physical details of viscous flow in ship roll motions and improve the accuracy of ship roll damping numerical simulation, the application of the Particle Image Velocimetry (PIV technique is investigated in model tests of forced ship rolling in calm water. The hydrodynamic force and flow field at the bilge region are simultaneously measured for barges at different amplitudes and frequencies in which the self-made forced rolling facility was used. In the model test, the viscous flow variation with the time around the bilge region was studied during ship rolling motion. The changes in ship roll damping coefficients with the rolling amplitude and period were also investigated. A comparison of the model test results with the Computational Fluid Dynamics(CFDresults shows that the numerical ship roll damping coefficients agree well with the model test results, while the differences in the local flow details exist between the CFD results and model test results. Further research into the model test technique and CFD application is required.

  18. Radiographers and radiologists reporting plain radiograph requests from accident and emergency and general practice

    International Nuclear Information System (INIS)

    Brealey, S.D.; King, D.G.; Hahn, S.; Crowe, M.; Williams, P.; Rutter, P.; Crane, S.

    2005-01-01

    AIM: To assess selectively trained radiographers and consultant radiologists reporting plain radiographs for the Accident and Emergency Department (A and E) and general practitioners (GPs) within a typical hospital setting. METHODS: Two radiographers, a group of eight consultant radiologists, and a reference standard radiologist independently reported under controlled conditions a retrospectively selected, random, stratified sample of 400 A and E and 400 GP plain radiographs. An independent consultant radiologist judged whether the radiographer and radiologist reports agreed with the reference standard report. Clinicians then assessed whether radiographer and radiologist incorrect reports affected confidence in their diagnosis and treatment plans, and patient outcome. RESULTS: For A and E and GP plain radiographs, respectively, there was a 1% (95% confidence interval (CI) -2 to 5) and 4% (95% CI -1 to 8) difference in reporting accuracy between the two professional groups. For both A and E and GP cases there was an 8% difference in the clinicians' confidence in their diagnosis based on radiographer or radiologist incorrect reports. For A and E and GP cases, respectively, there was a 2% and 8% difference in the clinicians' confidence in their management plans based on radiographer or radiologist incorrect reports. For A and E and GP cases, respectively, there was a 1% and 11% difference in effect on patient outcome of radiographer or radiologist incorrect reports. CONCLUSION: There is the potential to extend the reporting role of selectively trained radiographers to include plain radiographs for all A and E and GP patients. Further research conducted during clinical practice at a number of sites is recommended

  19. Comparisons of radiographic and electrocardiographic abnormalities in canine heartworm disease

    International Nuclear Information System (INIS)

    Calvert, C.A.; Losonsky, J.M.; Brown, J.; Lewis, R.E.

    1986-01-01

    Thoracic radiographs and electrocardiograms from 137 dogs with heartworm infection were independently evaluated and comparisons were made of (1) the presence or absence of right ventricular enlargement as assessed by these two diagnostic tests and (2) the presence or absence of right-sided congestive heart failure relative to the degree of right ventricular enlargement and ECG criteria of RVH. Radiographic evidence of severe, but not moderate, right ventricular enlargement was associated with right-sided congestive heart failure. Similarly the presence of three or more, but not fewer than three, ECG criteria of RVH were associated with right-sided congestive heart failure. If either the thoracic radiographs or the ECG indicated that severe right ventricular enlargement was absent, right-sided congestive heart failure was seldom present. The most accurate correlation of the radiographic evaluation of severe right ventricular enlargement was afforded by the presence of three or more ECG criteria of RVH. ECG criteria of RVH such as R/S v4 , + T v10 MEA x , and S 11 are highly specific tests; while S V2 is a highly sensitive but not highly specific test. The ECG is a good confirmation test of the presence of severe right ventricular enlargement and is a good exclusion test for the absence of right-sided congestive heart failure. (author)

  20. Correlating intravenous radiographic contrast media reactions with the allergic profile

    International Nuclear Information System (INIS)

    Chua-Lim, A.; Enright, T.; Duda, E.; Lim, D.T.

    1987-01-01

    To determine the relevance of allergy as a predisposing factor in reactions to radiographic contrast media, the authors investigated the incidence of allergy among 100 randomly selected patients undergoing intravenous excretory urography and CT. The study population consisted of 50 reactors and 50 nonreactos to radiographic contrast media. All 100 subjects completed an allergy history, percutaneous allergy tests, and an in vitro specific IgE assay to common allergens. Thirty-four of 50 reactors had a positive allergy history, in contrast to 15 of 50 nonreactors (P < .001). Twenty-seven reactors had positive skin tests, in contrast to 12 of 50 nonreactors (P < .005). In vitro IgE assay results are pending. The results indicate that patients with positive histories or positive skin tests or both are at an increased risk for reactions to radiographic contrast media

  1. The influence of a continuing education program on the image interpretation accuracy of rural radiographers.

    Science.gov (United States)

    Smith, Tony N; Traise, Peter; Cook, Aiden

    2009-01-01

    In regional, rural and remote clinical practice, radiographers work closely with medical members of the acute care team in the interpretation of radiographic images, particularly when no radiologist is available. However, the misreading of radiographs by non-radiologist physicians has been shown to be the most common type of clinical error in the emergency department. Further, in Australia few rural radiographers are specifically trained to interpret and report on images. This study aimed to evaluate the accuracy of a group of rural radiographers in interpreting musculoskeletal plain radiographs, and to assess the effectiveness of continuing education (CE) in improving their accuracy within a short time frame. Following ethics approval, 16 rural radiographers were recruited to the study. At inception a purpose-designed 'test-object' of 25 cases compiled by a radiologist was used to assess image interpretation accuracy. The cases were categorised into three grades of complexity. The radiographers entered their answers on a structured radiographer opinion form (ROF) that had three levels of response - 'general opinion', 'observations' and 'open comment'. Subsequent to base-line testing, the radiographers participated in a CE program aimed at improving their image interpretation skills. After a 4 month period they were re-tested using the same methodology. The ROFs were scored by the radiologist and the pooled results analysed for statistically significant changes at all ROF levels and grades of complexity. While for the small number of less complex grade 1 cases there was no change in image interpretation accuracy, for the more numerous and more complex grade 2 and grade 3 cases there was a statistically significant improvement at the 'general opinion' and 'observation' levels (paired t-test, p radiologist. However, radiographers' ability to use radiological vocabulary needs improvement. The complementary role that exists between radiographers and other members of

  2. Radiographic Prevalence of Dysplasia, Cam, and Pincer Deformities in Elite Ballet.

    Science.gov (United States)

    Harris, Joshua D; Gerrie, Brayden J; Varner, Kevin E; Lintner, David M; McCulloch, Patrick C

    2016-01-01

    The demands of hip strength and motion in ballet are high. Hip disorders, such as cam and pincer deformities or dysplasia, may affect dance performance. However, the prevalence of these radiographic findings is unknown. To determine the prevalence of radiographic cam and pincer deformities, borderline dysplasia, and dysplasia in a professional ballet company. Cross-sectional study; Level of evidence, 3. An institutional review board-approved cross-sectional investigation of a professional ballet company was undertaken. Male and female adult dancers were eligible for inclusion. Four plain radiographs were obtained (standing anteroposterior pelvis, bilateral false profile, and supine Dunn 45°) and verified for adequacy. Cam and pincer deformities, dysplasia, borderline dysplasia, and osteoarthritis were defined. All plain radiographic parameters were measured and analyzed on available radiographs. Student t test, chi-square test (and Fisher exact test), and Spearman correlation analyses were performed to compare sexes, groups, and the effect of select radiographic criteria. A total of 47 dancers were analyzed (21 males, 26 females; mean age (±SD), 23.8 ± 5.4 years). Cam deformity was identified in 25.5% (24/94) of hips and 31.9% (15/47) of subjects, with a significantly greater prevalence in male dancers than females (48% hips and 57% subjects vs 8% hips and 12% subjects; P ballet company, a high prevalence of radiographic abnormalities was found, including cam and pincer deformity and dysplasia. The results also revealed several sex-related differences of these abnormalities in this unique population. The long-term implications of these findings in this group of elite athletes remain unknown, and this issue warrants future investigation. © 2015 The Author(s).

  3. A Novel Disintegration Tester for Solid Dosage Forms Enabling Adjustable Hydrodynamics.

    Science.gov (United States)

    Kindgen, Sarah; Rach, Regine; Nawroth, Thomas; Abrahamsson, Bertil; Langguth, Peter

    2016-08-01

    A modified in vitro disintegration test device was designed that enables the investigation of the influence of hydrodynamic conditions on disintegration of solid oral dosage forms. The device represents an improved derivative of the compendial PhEur/USP disintegration test device. By the application of a computerized numerical control, a variety of physiologically relevant moving velocities and profiles can be applied. With the help of computational fluid dynamics, the hydrodynamic and mechanical forces present in the probe chamber were characterized for a variety of device moving speeds. Furthermore, a proof of concept study aimed at the investigation of the influence of hydrodynamic conditions on disintegration times of immediate release tablets. The experiments demonstrated the relevance of hydrodynamics for tablet disintegration, especially in media simulating the fasted state. Disintegration times increased with decreasing moving velocity. A correlation between experimentally determined disintegration times and computational fluid dynamics predicted shear stress on tablet surface was established. In conclusion, the modified disintegration test device is a valuable tool for biorelevant in vitro disintegration testing of solid oral dosage forms. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  4. A radiographic study of pediatric ulnar anatomy.

    Science.gov (United States)

    Cravino, Mattia; Oni, Julius K; Sala, Debra A; Chu, Alice

    2014-01-01

    The adult ulna has a unique bony architecture that has been described in the literature, but, to the best of our knowledge, the ulnar anatomy in children has not been described. We examined 75 anteroposterior (AP) and 64 lateral radiographs (29 were bilateral) of 50, 0.5- to 11-year-old, healthy children's forearms. On AP radiographs, the total ulnar length, the ulnar proximal angle, the ulnar distal angle, and the distance between each angle from the tip of the triceps insertion; and, on lateral radiographs, the ulnar length and bow deviation were measured. The correlation between age and radiographic measurements, differences based on sex, differences compared with adults' measurements, and interobserver/intraobserver reliability were assessed. Age had a very strong/strong positive correlation with length/distance measurements on both AP and lateral radiographs. Only AP ulnar distal angle was significantly different between sexes (females > males). Compared with the adult ulnar studies, the AP proximal angle in children is significantly smaller and the location of this angle is significantly more distal. Interobserver and intraobserver reliability were very good for length/distance measurements on AP and lateral radiographs. The knowledge of pediatric ulnar anatomy could be helpful in the treatment of forearm deformities due to multiple hereditary exostosis and osteogenesis imperfecta, and in the treatment of ulnar fractures, particularly in Monteggia variants, where restoration of the correct forearm anatomy is essential to obtain good clinical and functional results. Study of diagnostic test, Level II.

  5. Digitization of radiographic inspection for pipeline girth welded joints

    International Nuclear Information System (INIS)

    Uemura, Shimpei

    2016-01-01

    In radiographic inspection for the girth welded joints of natural gas pipeline, film radiographic testing (FRT) is applied presently in Japan. However, as of July 2016, the work of establishing JIS standard for radiographic inspection with digital detector is in progress. In order to provide users with the merit of digitization as soon as possible, the authors have developed NSDART (Nittetsu-Sumikin digital detector array technology) as a field X-ray inspection system for the girth welded joints of pipeline. This paper reports the required performances discussed in face of development of NSDART, selection of digital detector, and outline of NSDART, and shows part of the radiographic images acquired with NSDART. As required performances, the following were established: (1) required image quality for radiographic image, (2) identifiable minimum wire diameter of transmission meter, (3) density range of radiographic image and value of gradation meter, (4) spatial resolution via Duplex Wire, (5) X-ray generator, (6) real time performance, and (7) display for observing radiographic image. As for the selection of digital detector, flat panel detector was judged to be the most suitable, and its incorporation to NSDART was determined. NSDART devices are composed of a magnet-wheeled self-propelled imaging device, personal computer, controller, and externally installed display for judgment. (A.O.)

  6. Chest radiographic findings of tsutsugamushi disease and murine typhus in Chunchon

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Heung Chul; Han, Tae Giun; Jang, Won Ho; Hwang, Woo Chul; Park, Man Soo; Lee, Myoung Gu; Kim, Yoon Won [School of Medicine, Hallym University, Chuncheon (Korea, Republic of); Park, Choong Ki [College of Medicine, Hanyang University, Guri (Korea, Republic of)

    1995-06-15

    To evaluate the chest radiographic findings of rickettsial disease including murine typhus and tsutsugamushi disease in Chunchon. Chest radiographic films of 81 cases diagnosed as rickettsial disease(55 cases of tsutsugamushi disease, 26 cases of murine typhus) by immunofluorescence test were retrospectively analyzed. Main serotypes of Rickettsia tsutsugamushi were Gilliam and Karp. Incidence rate of tsutsugamushi disease was 2.1 times greater than that of murine typhus. Chest radiographs were abnormal in 63.6% of tsutsugamushi disease, and in 30.8% of murine typhus. Radiographic findings were Kerly's B line, reticulonodular densities, hilar enlargement, pleural effusion, and splenomegaly in both entities, but pulmonary consolidation was only found in tsutsugamushi disease. The patients with the abnormal radiographic findings were statistically well correlated with cardiomegaly ({rho} < 0.01) and azygos engorgement ({rho} < 0.05), as compared to the patients with normal radiographic findings. Radiographic findings of both murine typhus and tsutsugamushi disease were interstitial pattern. But the chest radiographs in patients with tsutsugamushi disease showed more severe pattern with higher rate of abnormality.

  7. Chest radiographic findings of tsutsugamushi disease and murine typhus in Chunchon

    International Nuclear Information System (INIS)

    Kim, Heung Chul; Han, Tae Giun; Jang, Won Ho; Hwang, Woo Chul; Park, Man Soo; Lee, Myoung Gu; Kim, Yoon Won; Park, Choong Ki

    1995-01-01

    To evaluate the chest radiographic findings of rickettsial disease including murine typhus and tsutsugamushi disease in Chunchon. Chest radiographic films of 81 cases diagnosed as rickettsial disease(55 cases of tsutsugamushi disease, 26 cases of murine typhus) by immunofluorescence test were retrospectively analyzed. Main serotypes of Rickettsia tsutsugamushi were Gilliam and Karp. Incidence rate of tsutsugamushi disease was 2.1 times greater than that of murine typhus. Chest radiographs were abnormal in 63.6% of tsutsugamushi disease, and in 30.8% of murine typhus. Radiographic findings were Kerly's B line, reticulonodular densities, hilar enlargement, pleural effusion, and splenomegaly in both entities, but pulmonary consolidation was only found in tsutsugamushi disease. The patients with the abnormal radiographic findings were statistically well correlated with cardiomegaly (ρ < 0.01) and azygos engorgement (ρ < 0.05), as compared to the patients with normal radiographic findings. Radiographic findings of both murine typhus and tsutsugamushi disease were interstitial pattern. But the chest radiographs in patients with tsutsugamushi disease showed more severe pattern with higher rate of abnormality

  8. Chest radiographic findings of tsutsugamushi disease and murine typhus in Chunchon

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Heung Chul; Han, Tae Giun; Jang, Won Ho; Hwang, Woo Chul; Park, Man Soo; Lee, Myoung Gu; Kim, Yoon Won [School of Medicine, Hallym University, Chuncheon (Korea, Republic of); Park, Choong Ki [College of Medicine, Hanyang University, Guri (Korea, Republic of)

    1995-06-15

    To evaluate the chest radiographic findings of rickettsial disease including murine typhus and tsutsugamushi disease in Chunchon. Chest radiographic films of 81 cases diagnosed as rickettsial disease(55 cases of tsutsugamushi disease, 26 cases of murine typhus) by immunofluorescence test were retrospectively analyzed. Main serotypes of Rickettsia tsutsugamushi were Gilliam and Karp. Incidence rate of tsutsugamushi disease was 2.1 times greater than that of murine typhus. Chest radiographs were abnormal in 63.6% of tsutsugamushi disease, and in 30.8% of murine typhus. Radiographic findings were Kerly's B line, reticulonodular densities, hilar enlargement, pleural effusion, and splenomegaly in both entities, but pulmonary consolidation was only found in tsutsugamushi disease. The patients with the abnormal radiographic findings were statistically well correlated with cardiomegaly ({rho} < 0.01) and azygos engorgement ({rho} < 0.05), as compared to the patients with normal radiographic findings. Radiographic findings of both murine typhus and tsutsugamushi disease were interstitial pattern. But the chest radiographs in patients with tsutsugamushi disease showed more severe pattern with higher rate of abnormality.

  9. Accuracy of chest radiographs in the emergency diagnosis of heart failure

    Energy Technology Data Exchange (ETDEWEB)

    Studler, Ueli; Kretzschmar, Martin; Steinbrich, Wolfgang [University Hospital Basel, Department of Radiology, Basel (Switzerland); Christ, Michael; Breidthardt, Tobias; Noveanu, Markus; Perruchoud, Andre P.; Mueller, Christian [University Hospital Basel, Department of Internal Medicine, Basel (Switzerland); Schoetzau, Andreas [Institute of Biostatistics, Basel (Switzerland)

    2008-08-15

    The purpose of this study was to determine the diagnostic accuracy of chest radiographic findings of heart failure (HF) in current patients presenting with dyspnea in the emergency department. In a secondary analysis of the BASEL study, initial chest radiographs of 277 patients with acute dyspnea were evaluated by two radiologists blinded to the adjudicated diagnosis (56% had the final diagnosis of HF). Predefined radiographic criteria of HF were used. Statistical analysis included receiver-operating characteristic (ROC) analysis and calculation of a logistic regression model including B-type natriuretic peptide (BNP) levels. The reader's overall impression showed the highest area under the ROC curve for the diagnosis of HF in both supine and erect patient positions (0.855 and 0.857). Among individual radiographic findings, peribronchial cuffing in the supine position (0.829) showed the highest accuracies. The lowest accuracy was found for the vascular pedicle width in the supine position (0.461). Logistic regression analysis showed no significant differences between the reader's overall impression, the radiographic model, and BNP testing. In our study, the combination of radiographic features provided valuable information and was of comparable accuracy as BNP-testing for the diagnosis of HF. (orig.)

  10. Radiographic appearance of the navicular bone in sound horses

    International Nuclear Information System (INIS)

    Kaser-Hotz, B.; Ueltschi, G.

    1992-01-01

    Radiographs of the navicular bone in 523 sound horses were reviewed. Detailed evaluation criteria were used. The incidence of radiographic changes and variations in normal horses were recorded. Results were tested for right-left limb difference and for age relationship. Variation in shape and bone structure was commonly seen in the navicular bone. Radiographic changes with an incidence of less than 2% included flexor cortex defects and calcification on the flexor surface. Fragments at the distal navicular bone border, calcification in the impar ligament and enthesiophytes at the proximal border were radiographic findings with an incidence of 2% to 10%. Abnormal canals at the distal border were found in 11% horses. Elongation of the lateral proximal extremity was commonly found. The mean width of the flexor cortex was 3.6 mm

  11. The radiographic image: A cultural artefact?

    International Nuclear Information System (INIS)

    Strudwick, Ruth M.

    2014-01-01

    This article looks at the role of the radiographic images produced by diagnostic radiographers. An ethnographic study of the workplace culture in one diagnostic imaging department was undertaken using participant observation for four months and semi-structured interviews with ten key informants. One of the key themes; that of the radiographic image as a cultural artefact, is explored in this article. The radiographic image is a cultural artefact which radiographers are protective of and take ownership of. Radiographers are conscious of the quality of their images and the images are an important aspect of their work. Radiographers take criticism of their images personally. The radiographic image is a record of the interaction that occurs between the radiographer and the patient. The way in which radiographic images are viewed, used and judged is an important aspect of the role of diagnostic radiographer

  12. Topical issues of radiographic testing and radiation protection. Papers

    International Nuclear Information System (INIS)

    1992-01-01

    The seven papers demonstrate current developments in radiation protection. The amendment of the Radiation Protection Ordinance and the new Ordinance on the Transport of Hazardous Goods by Road were discussed in particular. A major results of the discussion meeting was the foundation of the working group on 'Transport of radioactive substances'. In terms of radiographic practive, the authors addressed European standardization, instruments and technology in radioscopy, and computer-aided image processing. (orig./HP) [de

  13. Effectiveness of emergency nurses' use of the Ottawa Ankle Rules to initiate radiographic tests on improving healthcare outcomes for patients with ankle injuries: A systematic review.

    Science.gov (United States)

    Ho, Jonathan Ka-Ming; Chau, Janita Pak-Chun; Cheung, Nancy Man-Ching

    2016-11-01

    The Ottawa Ankle Rules provide guidelines for clinicians on the recommendation of radiographic tests to verify fractures in patients with ankle injuries. The use of the Ottawa Ankle Rules by emergency nurses has been suggested to minimise unnecessary radiographic-test requests and reduce patients' length of stay in emergency departments. However, the findings of studies in this area are inconsistent. A systematic review was conducted to synthesise the most accurate evidence available on the extent to which emergency nurses' use of the Ottawa Ankle Rules to initiate radiographic tests improves healthcare outcomes for patients with ankle injuries. The systematic review attempted to identify all relevant published and unpublished studies in English and Chinese from databases such as Ovid MEDLINE, EMBASE, ProQuest Health and Medical Complete, EBM Reviews, SPORTDiscus, CINAHL Plus, the British Nursing Index, Scopus, the Chinese Biomedical Literature Database, China Journal Net, WanFang Data, the National Central Library Periodical Literature System, HyRead, the Digital Dissertation Consortium, MedNar and Google Scholar. Two reviewers independently assessed the eligibility of all of the studies identified during the search, based on their titles and abstracts. If a study met the criteria for inclusion, or inconclusive information was available in its title and abstract, the full text was retrieved for further analysis. The methodological quality of all of the eligible studies was assessed independently by the two reviewers. The search of databases and other sources yielded 1603 records. The eligibility of 17 full-text articles was assessed, and nine studies met the inclusion criteria. All nine studies were subjected to narrative analysis, and five were meta-analysed. All of the studies investigated the use of the refined Ottawa Ankle Rules. The results indicated that emergency nurses' use of the refined Ottawa Ankle Rules minimised unnecessary radiographic-test requests

  14. Development and testing of texture discriminators for the analysis of trabecular bone in proximal femur radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Huber, M. B.; Carballido-Gamio, J.; Fritscher, K.; Schubert, R.; Haenni, M.; Hengg, C.; Majumdar, S.; Link, T. M. [Department of Radiology and Biomedical Imaging, University of California, 400 Parnassus Avenue, San Francisco, California 94143 (United States); University of Health Sciences, Medical Informatics and Technology, 6060 Hall (Austria); AO Development Institute, 7270 Davos Platz (Switzerland); Medical University Innsbruck, 6020 Innsbruck (Austria); Department of Radiology and Biomedical Imaging, University of California, 400 Parnassus Avenue, San Francisco, California 94143 (United States)

    2009-11-15

    Purpose: Texture analysis of femur radiographs may serve as a potential low cost technique to predict osteoporotic fracture risk and has received considerable attention in the past years. A further application of this technique may be the measurement of the quality of specific bone compartments to provide useful information for treatment of bone fractures. Two challenges of texture analysis are the selection of the best suitable texture measure and reproducible placement of regions of interest (ROIs). The goal of this in vitro study was to automatically place ROIs in radiographs of proximal femur specimens and to calculate correlations between various different texture analysis methods and the femurs' anchorage strength. Methods: Radiographs were obtained from 14 femoral specimens and bone mineral density (BMD) was measured in the femoral neck. Biomechanical testing was performed to assess the anchorage strength in terms of failure load, breakaway torque, and number of cycles. Images were segmented using a framework that is based on the usage of level sets and statistical in-shape models. Five ROIs were automatically placed in the head, upper and lower neck, trochanteric, and shaft compartment in an atlas subject. All other subjects were registered rigidly, affinely, and nonlinearly, and the resulting transformation was used to map the five ROIs onto the individual femora. Results: In each ROI, texture features were extracted using gray level co-occurence matrices (GLCM), third-order GLCM, morphological gradients (MGs), Minkowski dimensions (MDs), Minkowski functionals (MFs), Gaussian Markov random fields, and scaling index method (SIM). Coefficients of determination for each texture feature with parameters of anchorage strength were computed. In a stepwise multiregression analysis, the most predictive parameters were identified in different models. Texture features were highly correlated with anchorage strength estimated by the failure load of up to R{sup 2

  15. Initial image interpretation of appendicular skeletal radiographs: A comparison between nurses and radiographers

    International Nuclear Information System (INIS)

    Piper, Keith J.; Paterson, Audrey

    2009-01-01

    Purpose: To examine the effect of a short training programme on nurses and radiographers, exploring differences between their performance before and after training. Method: Twenty-two nurses and 18 radiographers interpreted 20 trauma radiographs of the appendicular skeleton before and after training. Normal and abnormal cases of a discriminatory nature were included. Total score, sensitivity and specificity values were calculated for each participant by comparison with an agreed expected answer. The area under the curve (AUC) was analysed using alternate free-response receiver operating characteristic (AFROC) methodology. Results: Significant differences were demonstrated between the total scores achieved by the two groups (pre-training: p = 0.007, post-training: p = 0.04). After training, the mean score increased significantly for both groups (p < 0.001). No significant difference was found between the radiographers mean pre-training scores and the nurses mean post-training scores (p = 0.66). Sensitivity for both groups increased following training, significantly so for the nurses (nurses: p < 0.001, radiographers: p = 0.06). Specificity reduced significantly after training for the nurses (p < 0.001), and increased for the radiographers but not significantly (p = 0.085). After training, there was no significant difference between the two groups in terms of sensitivity (p = 0.09) but specificity was significantly higher for the radiographers (p < 0.001). The radiographers achieved higher pre-training AUC values than the nurses (p = 0.04), although a difference remained after training this did not achieve statistical significance (p = 0.15). The AUC values increased significantly after training for both groups (nurses: p = 0.012, radiographers: p = 0.004) and again there was no significant difference between the radiographers pre-training performance and the nurses post-training performance (p = 0.62). Conclusion: Improvement after training was seen in both groups

  16. Invariant description of solutions of hydrodynamic-type systems in hodograph space: hydrodynamic surfaces

    International Nuclear Information System (INIS)

    Ferapontov, E.V.

    2002-01-01

    Hydrodynamic surfaces are solutions of hydrodynamic-type systems viewed as non-parametrized submanifolds of the hodograph space. We propose an invariant differential-geometric characterization of hydrodynamic surfaces by expressing the curvature form of the characteristic web in terms of the reciprocal invariants. (author)

  17. Student radiographers' attitudes toward the older patient – An intervention study

    International Nuclear Information System (INIS)

    Booth, L.; Kada, S.

    2015-01-01

    Purpose: To design, implement and evaluate the effect of an educational intervention on Norwegian student (diagnostic) radiographers' attitudes towards older people. Design: This study is part of a wider longitudinal study that will evaluate student radiographer attitudes towards the older patient as they progress through their training. In this phase an educational intervention, aimed at improving student radiographer attitudes towards the older person, was designed and implemented. What is reported here are the findings of a pre-test, post-test design that used the Kogan's attitudes towards older people scale to determine whether this intervention had any effect of student radiographer attitudes towards older people. Results: Overall students reported significantly more positive attitudes towards older people after intervention (p = 0.01). However, analysis of responses to individual questions reveals that this difference was not significant in all cases. Conclusion: The results of the present study suggest that an educational intervention can have a significant impact on student radiographer's attitudes towards older people. Whether this positive attitude remains throughout training, forms part of the wider basis for this study. - Highlights: • We designed an education intervention to improve Norwegian student radiographer attitudes towards older people. • Pre-intervention we found that these student radiographers generally had positive attitudes towards older people. • Post intervention the student radiographer's attitudes towards older people were significantly improved

  18. Reliability of cervical lordosis measurement techniques on long-cassette radiographs.

    Science.gov (United States)

    Janusz, Piotr; Tyrakowski, Marcin; Yu, Hailong; Siemionow, Kris

    2016-11-01

    Lateral radiographs are commonly used to assess cervical sagittal alignment. Three assessment methods have been described and are commonly utilized in clinical practice. These methods are described for perfect lateral cervical radiographs, however in everyday practice radiograph quality varies. The aim of this study was to compare the reliability and reproducibility of 3 cervical lordosis (CL) measurement methods. Forty-four standing lateral radiographs were randomly chosen from a lateral long-cassette radiograph database. Measurements of CL were performed with: Cobb method C2-C7 (CM), C2-C7 posterior tangent method (PTM), sum of posterior tangent method for each segment (SPTM). Three independent orthopaedic surgeons measured CL using the three methods on 44 lateral radiographs. One researcher used the three methods to measured CL three times at 4-week time intervals. Agreement between the methods as well as their intra- and interobserver reliability were tested and quantified by intraclass correlation coefficient (ICC) and median error for a single measurement (SEM). ICC of 0.75 or more reflected an excellent agreement/reliability. The results were compared with repeated ANOVA test, with p  0.05). All three methods appeared to be highly reliable. Although, high agreement between all measurement methods was shown, we do not recommend using Cobb measurement method interchangeably with PTM or SPTM within a single study as this could lead to error, whereas, such a comparison between tangent methods can be considered.

  19. Visual simulation of radiographs

    International Nuclear Information System (INIS)

    Laguna, G.

    1985-01-01

    A method for computer simulation of radiographs has been added to the LLNL version of the solid modeler TIPS-1 (Technical Information Processing System-1). This new tool will enable an engineer to compare an actual radiograph of a solid to its computer-generated counterpart. The appearance of discrepancies between the two can be an indication of flaws in the solid object. Simulated radiographs can also be used to preview the placement of x-ray sources to focus on areas of concern before actual radiographs are made

  20. Radiographic examination of the equine foot

    International Nuclear Information System (INIS)

    Park, R.D.

    1989-01-01

    A complete radiographic examination of the equine foot consists of properly exposed, processed, and positioned radiographs. For radiographic interpretation, in addition to knowing radiographic signs of disease, a knowledge of normal radiographic anatomy and possible insignificant anatomic variations is necessary

  1. Radiographic inspection and densitometric evaluation of CP-5 reactor fuel

    International Nuclear Information System (INIS)

    Staroba, J.F.; Knoerzer, T.W.

    1978-02-01

    This report covers the radiographic and densitometric techniques used as part of a quality verification program for CP-5 reactor fuel by the Nondestructive Assay Section of the Special Materials Division. Other nondestructive tests used were ultrasonic and gamma-ray spectrometry. The main objectives were to perform a one-hundred percent radiographic inspection of the fuel tubes and to derive a quantitative relationship between fuel thickness and film density with the use of fabricated fuel step wedges. By the use of tangential x-ray techniques, measurements were made of fuel peaks or ''hot spots'' that protruded above the main fuel line. Other general problems in radiographic inspection and solutions for the upgrading of the total radiographic inspection program are also discussed

  2. A Platform for X-Ray Thomson Scattering Measurements of Radiation Hydrodynamics Experiments on the NIF

    Science.gov (United States)

    Lefevre, Heath; Ma, Kevin; Belancourt, Patrick; MacDonald, Michael; Doeppner, Tilo; Keiter, Paul; Kuranz, Carolyn

    2017-10-01

    A recent experiment on the National Ignition Facility (NIF) radiographed the evolution of the Rayleigh-Taylor (RT) instability under high and low drive cases. This experiment showed that under a high drive the growth rate of the RT instability is reduced relative to the low drive case. The high drive launches a radiative shock, increases the temperature of the post-shock region, and ablates the spikes, which reduces the RT growth rate. The plasma parameters must be measured to validate this claim. We present a target design for making X-Ray Thomson Scattering (XRTS) measurements on radiation hydrodynamics experiments on NIF to measure the electron temperature of the shocked region in the above cases. Specifically, we show that a previously fielded NIF radiation hydrodynamics platform can be modified to allow sufficient signal and temperature resolution for XRTS measurements. This work is funded by the NNSA-DS and SC-OFES Joint Program in High-Energy-Density Laboratory Plasmas, Grant Number DE-NA0002956 and the National Science Foundation through the Basic Plasma Science and Engineering program.

  3. Study on the abnormal image appeared in radiographs of welds, 3

    International Nuclear Information System (INIS)

    Hayashi, Morihiro; Sugimura, Seiichi; Umemura, Kunio; Imamura, Senji; Kanno, Munekazu.

    1984-01-01

    On the abnormal images arising at times in the X-ray radiographs of austenitic stainless steel welded parts, the cause of occurrence was clarified before. In this study, the authors made the welded parts of austenitic stainless steel SUS 304 and SUS 316 with abnormal images of different clearness by making heat input into respective layers of welds large or small, and compared the static and dynamic strength. Moreover, the relation of the form of abnormal images in radiographs to metal structures was studied. The welding method employed was TIG welding and submerged arc welding. The images of X-ray radiographs and the metal structures of the welded parts tested are shown. The mechanical strength test was carried out by tension, bending and impact. Also fatigue test was performed. In the welded parts of SUS 304 and SUS 316, even if abnormal images appeared in radiographs, when sound welding was made, they possessed sufficient strength statically and dynamically. In the macroscopic and microscopic cross-sectional structures of the welded parts with remarkable abnormal images, defect was not observed at all. The cause of abnormal image appearance is the diffraction of X-ray. (Kako, I.)

  4. Coronal and Intraradicular Appearances Affect Radiographic Perception of the Periapical Region.

    Science.gov (United States)

    Strong, Julie W; Woodmansey, Karl F; Khademi, John A; Hatton, John F

    2017-05-01

    The influence of the radiographic appearances of the coronal and intraradicular areas on periapical radiographic interpretation has been minimally evaluated in dentistry and endodontics. The purpose of this study was to evaluate the effects that the coronal and intraradicular radiographic appearance has on endodontists' radiographic interpretations of periapical areas. In a split-group study design using an online survey format, 2 pairs of digital periapical radiographic images were evaluated by 2 groups (A and B) of endodontist readers for the presence of a periapical finding. The images in each pair were identical except that 1 image of each image pairs had coronal restorations and/or root canal fillings altered using Adobe Photoshop software (Adobe Systems, San Jose, CA). The periapical areas were not altered. Using a 5-point Likert scale, the endodontist readers were asked to "Please evaluate the periapical area(s)." A Mann-Whitney U test was used to statistically evaluate the difference between the groups. Significance was set at P < .01. There were 417 readers in group A and 442 readers in group B. The Mann-Whitney U test showed a significant difference in the responses between the groups for both image pairs (P < .01). Because the periapical areas of the image pairs were unaltered, the differing coronal and intraradicular areas of the radiographs appear to have influenced endodontists' interpretations of the periapical areas. This finding has implications for all radiographic outcome assessments. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  5. Hydrodynamic perception in true seals (Phocidae) and eared seals (Otariidae).

    Science.gov (United States)

    Hanke, Wolf; Wieskotten, Sven; Marshall, Christopher; Dehnhardt, Guido

    2013-06-01

    Pinnipeds, that is true seals (Phocidae), eared seals (Otariidae), and walruses (Odobenidae), possess highly developed vibrissal systems for mechanoreception. They can use their vibrissae to detect and discriminate objects by direct touch. At least in Phocidae and Otariidae, the vibrissae can also be used to detect and analyse water movements. Here, we review what is known about this ability, known as hydrodynamic perception, in pinnipeds. Hydrodynamic perception in pinnipeds developed convergently to the hydrodynamic perception with the lateral line system in fish and the sensory hairs in crustaceans. So far two species of pinnipeds, the harbour seal (Phoca vitulina) representing the Phocidae and the California sea lion (Zalophus californianus) representing the Otariidae, have been studied for their ability to detect local water movements (dipole stimuli) and to follow hydrodynamic trails, that is the water movements left behind by objects that have passed by at an earlier point in time. Both species are highly sensitive to dipole stimuli and can follow hydrodynamic trails accurately. In the individuals tested, California sea lions were clearly more sensitive to dipole stimuli than harbour seals, and harbour seals showed a superior trail following ability as compared to California sea lions. Harbour seals have also been shown to derive additional information from hydrodynamic trails, such as motion direction, size and shape of the object that caused the trail (California sea lions have not yet been tested). The peculiar undulated shape of the harbour seals' vibrissae appears to play a crucial role in trail following, as it suppresses self-generated noise while the animal is swimming.

  6. Minimum joint space width (mJSW) of patellofemoral joint on standing ''skyline'' radiographs: test-retest reproducibility and comparison with quantitative magnetic resonance imaging (qMRI)

    Energy Technology Data Exchange (ETDEWEB)

    Simoni, Paolo; Jamali, Sanaa; Alvarez Miezentseva, Victoria [CHU de Liege, Diagnostic Imaging Departement, Domanine du Sart Tilman, Liege (Belgium); Albert, Adelin [CHU de Liege, Biostatistics Departement, Domanine du Sart Tilman, Liege (Belgium); Totterman, Saara; Schreyer, Edward; Tamez-Pena, Jose G. [Qmetrics Technologies, Rochester, NY (United States); Zobel, Bruno Beomonte [Campus Bio-Medico University, Diagnostic Imaging Departement, Rome (Italy); Gillet, Philippe [CHU de Liege, Orthopaedic surgery Department, Domanine du Sart Tilman, Liege (Belgium)

    2013-11-15

    To assess the intraobserver, interobserver, and test-retest reproducibility of minimum joint space width (mJSW) measurement of medial and lateral patellofemoral joints on standing ''skyline'' radiographs and to compare the mJSW of the patellofemoral joint to the mean cartilage thickness calculated by quantitative magnetic resonance imaging (qMRI). A couple of standing ''skyline'' radiographs of the patellofemoral joints and MRI of 55 knees of 28 volunteers (18 females, ten males, mean age, 48.5 {+-} 16.2 years) were obtained on the same day. The mJSW of the patellofemoral joint was manually measured and Kellgren and Lawrence grade (KLG) was independently assessed by two observers. The mJSW was compared to the mean cartilage thickness of patellofemoral joint calculated by qMRI. mJSW of the medial and lateral patellofemoral joint showed an excellent intraobserver agreement (interclass correlation (ICC) = 0.94 and 0.96), interobserver agreement (ICC = 0.90 and 0.95) and test-retest agreement (ICC = 0.92 and 0.96). The mJSW measured on radiographs was correlated to mean cartilage thickness calculated by qMRI (r = 0.71, p < 0.0001 for the medial PFJ and r = 0.81, p < 0.0001 for the lateral PFJ). However, there was a lack of concordance between radiographs and qMRI for extreme values of joint width and KLG. Radiographs yielded higher joint space measures than qMRI in knees with a normal joint space, while qMRI yielded higher joint space measures than radiographs in knees with joint space narrowing and higher KLG. Standing ''skyline'' radiographs are a reproducible tool for measuring the mJSW of the patellofemoral joint. The mJSW of the patellofemoral joint on radiographs are correlated with, but not concordant with, qMRI measurements. (orig.)

  7. Attitudes of radiographers to radiographer-led discharge: A survey

    International Nuclear Information System (INIS)

    Lumsden, Laura; Cosson, Philip

    2015-01-01

    Background: The traditional role of the Diagnostic Radiographer in image acquisition has gradually been extended through skill-mix, particularly to include abnormality detection. Aims: This research focused on the attitudes of Radiographers to Radiographer-led Discharge (RLD), where Radiographers discharge patients with minor injuries and perform tasks previously undertaken by Accident and Emergency staff. The effects of job role, hospital type, experience and whether RLD was used in the participant's trust were examined. Method: A multiple-indicator online questionnaire assessed attitudes to RLD. Snowball sampling was used with advertisement via emails, posters and cards, containing Quick Response (QR) codes. Statement responses were coded, with reverse coding for negative statements and total scores were calculated. A higher score represented a more positive attitude. Results: 101 questionnaires were completed (an estimated 30% response rate) and the mean total score was 84/115. 95% of participants supported radiographer involvement in abnormality detection, with 46.5% selecting RLD as the preferred system for minor injuries patients vs 48.5% preferring commenting alone. Discussion: Participants were positive about extending their role through RLD and felt confident in their image interpretation abilities, though expressed concern for the legal consequences of the role and adequate pay. Generalization of the results is limited due to the possible low response rate. Conclusion: Overall, participants demonstrated positive attitudes towards RLD but they also indicate the need for appropriate payment for any additional responsibility. These findings are promising for successful implementation of RLD, though larger-scale research including radiologists, business managers, A and E staff and patients would be beneficial. - Highlights: • 101 questionnaires were completed (an estimated 30% response rate). • 95% of participants supported radiographer involvement

  8. Defects quantization in industrial radiographs by image processing

    International Nuclear Information System (INIS)

    Briand, F.Y.; Brillault, B.; Philipp, S.

    1988-01-01

    This paper refers to the industrial application of image processing using Non Destructive Testing by radiography. The various problems involved by the conception of a numerical tool are described. This tool intends to help radiograph experts to quantify defects and to follow up their evolution, using numerical techniques. The sequences of processings that achieve defect segmentation and quantization are detailed. They are based on the thorough knowledge of radiographs formation techniques. The process uses various methods of image analysis, including textural analysis and morphological mathematics. The interface between the final product and users will occur in an explicit language, using the terms of radiographic expertise without showing any processing details. The problem is thoroughly described: image formation, digitization, processings fitted to flaw morphology and finally product structure in progress. 12 refs [fr

  9. Sensitometric properties and image quality of radiographic film and paper

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1985-01-01

    When using X-ray film or radiographic paper for industrial applications one is interested in knowing not only their sensitometric properties (such as speed and contrast) but also the image quality obtainable with a particular brand of film or paper. Although standard methods for testing sensitometric properties and image quality separately are available, it is desirable to find a method by the use of which all the relevant properties could be tested together. The sensitometric properties are usually determined at constant kilovoltage and filtration at the X-ray tube, whereas the radiographic image quality is tested at different kilovoltages and for different material thicknesses

  10. Advanced Neutron Radiographic Equipment within the US Army

    Science.gov (United States)

    2014-01-29

    The first of the two new neutron generators developed for ARDEC was built and delivered by Phoenix Nuclear Labs ( PNL ) located in Madison, WI...PRELIMINARY NEUTRON RADIOGRAPHS AND RESULTS During the hardware and software testing of the PNL neutron generator several test shots were

  11. Digital image analysis of NDT radiographs

    International Nuclear Information System (INIS)

    Graeme, W.A. Jr.; Eizember, A.C.; Douglass, J.

    1989-01-01

    Prior to the introduction of Charge Coupled Device (CCD) detectors the majority of image analysis performed on NDT radiographic images was done visually in the analog domain. While some film digitization was being performed, the process was often unable to capture all the usable information on the radiograph or was too time consuming. CCD technology now provides a method to digitize radiographic film images without losing the useful information captured in the original radiograph in a timely process. Incorporating that technology into a complete digital radiographic workstation allows analog radiographic information to be processed, providing additional information to the radiographer. Once in the digital domain, that data can be stored, and fused with radioscopic and other forms of digital data. The result is more productive analysis and management of radiographic inspection data. The principal function of the NDT Scan IV digital radiography system is the digitization, enhancement and storage of radiographic images

  12. Chest radiographic findings in neurotuberculosis without pulmonary signs and symptoms

    International Nuclear Information System (INIS)

    Aurangzeb, S.; Badshah, M.; Khan, B.R.S.

    2008-01-01

    To determine the chest radiographic findings in patients of adult neurotuberculosis, with no pulmonary signs and symptoms. A total of 100 patients fulfilling pre-defined criteria of neurotuberculosis were included. Chest radiographic (CXR) evidence of pulmonary TB was looked for in those patients and its frequency, pattern and association with the clinical grades at presentation was determined by using Chi-square test. Out of the 100 patients of neurotuberculosis, with no clinical evidence of pulmonary TB, radiographic evidence of pulmonary TB was seen in only 30% patients. The predominant patterns on CXR were apical infiltration (26.6%), military mottling (20%) and hilar enlargement (16.6%). Positive CXR was found in 16.7% patients in clinical grade I and 40% and 43.3% in patients in grade II and III respectively. There was a strong association of grade II and grade III with positive chest radiographic findings (p= 0.03). Patients of neurotuberculosis may have chest radiographic evidence of pulmonary TB even in the absence of pulmonary signs and symptoms at presentation. There is a strong association of clinical grade II and grade III with positive chest radiographic findings. (author)

  13. Application of artificial neural network in radiographic diagnosis

    International Nuclear Information System (INIS)

    Piraino, D.; Amartur, S.; Richmond, B.; Schils, J.; Belhobek, G.

    1990-01-01

    This paper reports on an artificial neural network trained to rate the likelihood of different bone neoplasms when given a standard description of a radiograph. A three-layer back propagation algorithm was trained with descriptions of examples of bone neoplasms obtained from standard radiographic textbooks. Fifteen bone neoplasms obtained from clinical material were used as unknowns to test the trained artificial neural network. The artificial neural network correctly rated the pathologic diagnosis as the most likely diagnosis in 10 of the 15 unknown cases

  14. A self-directed learning intervention for radiographers rating mammographic breast density

    International Nuclear Information System (INIS)

    Ekpo, E.U.; Hogg, P.; Wasike, E.; McEntee, M.F.

    2017-01-01

    Purpose: Subjective methods of mammographic breast density (MBD) assessment are prone to inter-reader variability. This work aims to assess the impact of a short self-directed, experiential learning intervention on radiographers' reproducibility of MBD assessment. Method: The study used two sets of images (test and learning intervention) containing left craniocaudal and left mediolateral oblique views. The test set had MBD ratings from Volpara™ and radiologists using the fourth edition Breast Imaging and Data Systems (BI-RADS ® ). Seven radiographers rated the MBD of the test set before and after a self-directed learning intervention using the percentage descriptors in the fourth edition BI-RADS ® Atlas. The inter-reader agreement, the agreement between radiographers and Volpara™ as well as radiologists, was assessed using a Weighted Kappa (κ w ). Results: Overall, radiographers' inter-reader agreement (κ w ) was substantial (0.79; 95% CI: 0.70–0.87) before the intervention and almost perfect (0.84; 95% CI: 0.77–0.90) after the intervention. Before the intervention, radiographers demonstrated fair agreement with radiologists (0.24; 95% CI: −0.46–0.61) and Volpara™ (0.24; 95% CI: −0.41–0.59). A fair but slightly improved agreement was also observed between radiographers and radiologists (0.31; 95% CI: −0.33–0.64) as well as Volpara™ (0.28; 95% CI: −0.34–0.61) after the intervention. Conclusion: Findings demonstrate that a short duration self-directed, experiential learning intervention reduces inter-reader differences in MBD classification, but has a negligible impact on improving the agreement between inexperienced and expert readers. - Highlights: • Radiographers' MBD rating show fair agreement with radiologists and Volpara™. • Experiential learning intervention improved reproducibility of MBD classification. • Enhanced MBD rating training may be required to develop a standard fit for practice.

  15. High-Throughput Classification of Radiographs Using Deep Convolutional Neural Networks.

    Science.gov (United States)

    Rajkomar, Alvin; Lingam, Sneha; Taylor, Andrew G; Blum, Michael; Mongan, John

    2017-02-01

    The study aimed to determine if computer vision techniques rooted in deep learning can use a small set of radiographs to perform clinically relevant image classification with high fidelity. One thousand eight hundred eighty-five chest radiographs on 909 patients obtained between January 2013 and July 2015 at our institution were retrieved and anonymized. The source images were manually annotated as frontal or lateral and randomly divided into training, validation, and test sets. Training and validation sets were augmented to over 150,000 images using standard image manipulations. We then pre-trained a series of deep convolutional networks based on the open-source GoogLeNet with various transformations of the open-source ImageNet (non-radiology) images. These trained networks were then fine-tuned using the original and augmented radiology images. The model with highest validation accuracy was applied to our institutional test set and a publicly available set. Accuracy was assessed by using the Youden Index to set a binary cutoff for frontal or lateral classification. This retrospective study was IRB approved prior to initiation. A network pre-trained on 1.2 million greyscale ImageNet images and fine-tuned on augmented radiographs was chosen. The binary classification method correctly classified 100 % (95 % CI 99.73-100 %) of both our test set and the publicly available images. Classification was rapid, at 38 images per second. A deep convolutional neural network created using non-radiological images, and an augmented set of radiographs is effective in highly accurate classification of chest radiograph view type and is a feasible, rapid method for high-throughput annotation.

  16. Pocket atlas of radiographic anatomy

    International Nuclear Information System (INIS)

    Moeller, T.B.; Reif, E.; Stark, P.

    1993-01-01

    The 'Pocket Atlas of Radiographic Anatomy' presents 170 radiographs of the various body regions of adults, showing only the normal radiographic anatomy. Each radiograph is supplemented on the opposite page by a drawing of the particular body region. There is no commenting text, but the drawings are provided with captions in English. The atlas is a useful guide for interpreting radiographs. The pictures are arranged in chapters entitled as follows: Skeletal Imaging (skull, spine, upper extremity), lower extremity; Miscellaneous Plain Films (chest, mammogram, trachea, lung tomograms); Contrast Examinations (gastrointestinal tract, intravenous contrast examinations, arthrography, angiography); Special Examinations (myelograms, lymphangiograms, bronchograms, sialograms). (UWA). 348 figs [de

  17. Radiographic and computed tomographic evaluation of otitis media in the dog

    International Nuclear Information System (INIS)

    Love, N.E.; Kramer, R.W.; Spodnick, G.J.; Thrall, D.E.

    1995-01-01

    The purpose of this study was to compare computed tomography (CT) and radiography in the identification of canine middle ear disease. Fourteen canine patients underwent a radiographic “bullae series” and CT examination of the tympanic bullae. Confirmation of otitis media was based on surgery. The overall diagnostic accuracy of CT and radiographs regarding the diagnosis of otitis media was similar. Although a marked difference was not detected between radiographs and CT for detecting otitis media using Youden's index values, CT was a more sensitive test for the detection of otitis media

  18. [Transparency regime: semiotics of radiographical images in urological diagnostics].

    Science.gov (United States)

    Martin, M; Fangerau, H

    2012-10-01

    Shortly after Röntgen discovered x-rays urology became one of the main test fields for the application of this new technology. Initial scepticism among physicians, who were inclined to cling to traditional manual methods of diagnosing, was replaced by enthusiasm for radiographic technologies and the new method soon became the standard in, for example the diagnosis of concrements. Patients favoring radiographic procedures over the use of probes and a convincing documentation of stones in radiograms were factors that impacted the relatively rapid integration of radiology into urology. The radiographic representation of soft tissues and body cavities was more difficult and the development of contrast agents in particular posed a serious problem. Several patients died during this research. A new diagnostic dimension was revealed when radiography and cystography were combined to form the method of retrograde pyelography. However, the problem of how urologists could learn how to read the new images remained. In order to allow trainee physicians to practice interpreting radiograms atlases were produced which offered explanatory texts and drawings for radiographic images of the kidneys, the bladder etc. Thus, urologists developed a self-contained semiotics which facilitated the appropriation of a unique urological radiographical gaze.

  19. Rippled shock front solutions for testing hydrodynamic stability simulations

    International Nuclear Information System (INIS)

    Munro, D.H.

    1989-01-01

    The response of a shock front to arbitrary small perturbations can be calculated analytically. Such rippled shock front solutions are useful for determining the accuracy of hydrodynamic simulation codes such as LASNEX [Comments Plasma Phys. Controlled Fusion 2, 51 (1977)], which are used to compute perturbation growth in inertial fusion targets. The LASNEX fractional errors are of order κ 2 L 2 , where κ is the transverse wavenumber of the perturbation, and L is the largest zone dimension. Numerical errors are about 25% for a calculation using 26 zones per transverse wavelength

  20. Electrochemical Genotoxicity Assay Based on a SOS/umu Test Using Hydrodynamic Voltammetry in a Droplet

    Science.gov (United States)

    Kuramitz, Hideki; Sazawa, Kazuto; Nanayama, Yasuaki; Hata, Noriko; Taguchi, Shigeru; Sugawara, Kazuharu; Fukushima, Masami

    2012-01-01

    The SOS/umu genotoxicity assay evaluates the primary DNA damage caused by chemicals from the β-galactosidase activity of S. typhimurium. One of the weaknesses of the common umu test system based on spectrophotometric detection is that it is unable to measure samples containing a high concentration of colored dissolved organic matters, sediment, and suspended solids. However, umu tests with electrochemical detection techniques prove to be a better strategy because it causes less interference, enables the analysis of turbid samples and allows detection even in small volumes without loss of sensitivity. Based on this understanding, we aim to develop a new umu test system with hydrodynamic chronoamperometry using a rotating disk electrode (RDE) in a microliter droplet. PAPG when used as a substrate is not electroactive at the potential at which PAP is oxidized to p-quinone imine (PQI), so the current response of chronoamperometry resulting from the oxidation of PAP to PQI is directly proportional to the enzymatic activity of S. typhimurium. This was achieved by performing genotoxicity tests for 2-(2-furyl)-3-(5-nitro-2-furyl)-acrylamide (AF-2) and 2-aminoanthracene (2-AA) as model genotoxic compounds. The results obtained in this study indicated that the signal detection in the genotoxicity assay based on hydrodynamic voltammetry was less influenced by the presence of colored components and sediment particles in the samples when compared to the usual colorimetric signal detection. The influence caused by the presence of humic acids (HAs) and artificial sediment on the genotoxic property of selected model compounds such as 4-nitroquinoline-N-oxide (4-NQO), 3-chloro-4-(dichloromethyl)-5-hydroxy-2(5H)-furanone (MX), 1,8-dinitropyrene (1,8-DNP) and 1-nitropyrene (1-NP) were also investigated. The results showed that the genotoxicity of 1-NP and MX changed in the presence of 10 mg·L−1 HAs. The genotoxicity of tested chemicals with a high hydrophobicity such as 1,8-DNP

  1. Radiographic examination of the equine head

    International Nuclear Information System (INIS)

    Park, R.D.

    1993-01-01

    Radiographic examinations of the equine head can be performed with portable x-ray machines. The views comprising the examination depend on the area of the head being examined. With a knowledge of radiographic anatomy and radiographic signs of disease, valuable diagnostic information can be obtained from the radiographic examination. In addition, the radiographic information can also be used to develop a prognosis and determine the most appropriate therapy

  2. Hydrodynamic Modeling of Santa Marta's Big Marsh

    International Nuclear Information System (INIS)

    Saldarriaga, Juan

    1991-01-01

    The ecological degradation of Santa Marta's Big Marsh and their next areas it has motivated the realization of diagnosis studies and design by several state and private entities. One of the recommended efforts for international advisory it was to develop an ecological model that allowed the handling of the water body and the economic test of alternative of solution to those ecological problems. The first part of a model of this type is in turn a model that simulates the movement of the water inside the marsh, that is to say, a hydrodynamic model. The realization of this was taken charge to the civil engineering department, on the part of Colciencias. This article contains a general explanation of the hydrodynamic pattern that this being developed by a professors group. The ecological causes are described and antecedent, the parts that conform the complex of the Santa Marta big Marsh The marsh modeling is made and it is explained in qualitative form the model type Hydrodynamic used

  3. A retrospective study of the performance of radiographers in interpreting screening mammograms

    International Nuclear Information System (INIS)

    Moran, S.; Warren-Forward, H.

    2011-01-01

    Purpose: This paper provides data on the continued success of radiographers in reviewing mammograms with similar accuracy to screen readers. Method: The participants consisted of 7 radiographers and 2 current official screen readers. Two hundred and fifty sets of mammograms from 2003 were used in this study. Each participant reviewed each set of mammograms as a Rescreen or Recall. Patient outcomes were assessed by following up the results of any histology or pathology tests in 2003 or the 2005/2006 screening results. Results: The screen reader's sensitivities ranged from 79% to 93% and the specificities ranged from 82% to 84%. The radiographer values ranged from 57% to 97% and 63% to 80% respectively. Conclusion: The sensitivity and specificity values attained by some radiographers were equivalent to those of both the screen readers. Accuracy rates of the radiographers suggest that screen reading by selected and appropriately trained radiographers should be achievable in Australia.

  4. Study on transient hydrodynamic performance and cavitation characteristic of high-speed mixed-flow pump

    International Nuclear Information System (INIS)

    Chen, T; Liu, Y L; Sun, Y B; Wang, L Q; Wu, D Z

    2013-01-01

    In order to analyse the hydrodynamic performance and cavitation characteristic of a high-speed mixed-flow pump during transient operations, experimental studies were carried out. The transient hydrodynamic performance and cavitation characteristics of the mixed-flow pump with guide vane during start-up operation processes were tested on the pump performance test-bed. Performance tests of the pump were carried out under various inlet pressures and speed-changing operations. The real-time instantaneous external characteristics such as rotational speed, hydraulic head, flow rate, suction pressure and discharge pressure of the pump were measured. Based on the experimental results, the effect of fluid acceleration on the hydrodynamic performances and cavitation characteristics of the mixed-flow pump were analysed and evaluated

  5. Three-dimensional hindfoot alignment measurements based on biplanar radiographs: comparison with standard radiographic measurements

    International Nuclear Information System (INIS)

    Sutter, Reto; Pfirrmann, Christian W.A.; Buck, Florian M.; Espinosa, Norman

    2013-01-01

    To establish a hindfoot alignment measurement technique based on low-dose biplanar radiographs and compare with hindfoot alignment measurements on long axial view radiographs, which is the current reference standard. Long axial view radiographs and low-dose biplanar radiographs of a phantom consisting of a human foot skeleton embedded in acrylic glass (phantom A) and a plastic model of a human foot in three different hindfoot positions (phantoms B1-B3) were imaged in different foot positions (20 internal to 20 external rotation). Two independent readers measured hindfoot alignment on long axial view radiographs and performed 3D hindfoot alignment measurements based on biplanar radiographs on two different occasions. Time for three-dimensional (3D) measurements was determined. Intraclass correlation coefficients (ICC) were calculated. Hindfoot alignment measurements on long axial view radiographs were characterized by a large positional variation, with a range of 14 /13 valgus to 22 /27 varus (reader 1/2 for phantom A), whereas the range of 3D hindfoot alignment measurements was 7.3 /6.0 to 9.0 /10.5 varus (reader 1/2 for phantom A), with a mean and standard deviation of 8.1 ± 0.6/8.7 ± 1.4 respectively. Interobserver agreement was high (ICC = 0.926 for phantom A, and ICC = 0.886 for phantoms B1-B3), and agreement between different readouts was high (ICC = 0.895-0.995 for reader 1, and ICC = 0.987-0.994 for reader 2) for 3D measurements. Mean duration of 3D measurements was 84 ± 15/113 ± 15 s for reader 1/2. Three-dimensional hindfoot alignment measurements based on biplanar radiographs were independent of foot positioning during image acquisition and reader independent. In this phantom study, the 3D measurements were substantially more precise than the standard radiographic measurements. (orig.)

  6. Radiographic positioning

    International Nuclear Information System (INIS)

    Eisenberg, R.L.; Dennis, C.A.; May, C.

    1989-01-01

    This book concentrates on the routine radiographic examinations commonly performed. It details the wide variety of examinations possible and their place in initial learning and in the radiology department as references for those occasions when an unusual examination is requested. This book provides information ranging from basic terminology to skeletal positioning to special procedures. Positions are discussed and supplemented with a picture of a patient, the resulting radiograph, and a labeled diagram. Immobilization and proper shielding of the patient are also shown

  7. A radiographic study of the position and shape of mental foramen in panoramic radiographs

    International Nuclear Information System (INIS)

    Choi, Karp Shik; Kim, Dong Youn; Sohn, Jeong Ick; Bae, Yong Chul

    1997-01-01

    The purpose of this study was to evaluate the position and shape of mental foramen in panoramic radiographs. For this study, panoramic radiographs were obtained from the 200 adults and evaluated the position and shape of mental foramen. According to various positional changes in panoramic radiographs of the patients, the author also obtained panoramic radiographs from the 100 adults and then evaluated the positional and shape changes of mental foramen. The following results were obtained : 1. Shapes of mental foramen were observed elliptical (43.3%), round or oval (42.5%), unidentified (7.5%) and diffuse (6.7%) type in descending order of frequency. 2. Horizontal position of mental foramen were most frequently observed at the 2nd premolar area (54.2%), and area between the 1st premolar and 2nd premolar (43.1%), area between the 2nd premolar and 1st molar (2.7%), and at apex (9.7%), overlap with apex (1.9%), superior of apex (0.2%) in descending order of frequency. 4. According to various positional changes in panoramic radiographs of the patients, shape changes of mental foramen were more obviously observed at the forward 10 mm and chin down 10 degree positioned panoramic radiographs, And changes of horizontal and vertical position were observed in similar to compared with normal positioned panoramic radiographs.

  8. The Nature of Scatter at the DARHT Facility and Suggestions for Improved Modeling of DARHT Facility

    Energy Technology Data Exchange (ETDEWEB)

    Morneau, Rachel Anne [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-11-09

    This report describes the US Stockpile Stewardship Program which is meant to sustain and evaluate nuclear weapon stockpile with no underground nuclear tests. This research will focus on DARHT, the Dual Axis Radiographic Hydrodynamic Test facility.

  9. Validation of the plain chest radiograph for epidemiologic studies of airflow obstruction

    International Nuclear Information System (INIS)

    Musk, A.W.

    1982-01-01

    The chest radiographs of 125 industrial workers from rural New South Wales were examined for overinflated lungs, with and without attenuated midzonal vessels. Although the mean values of a comprehensive range of pulmonary function tests in the whole group were within normal limits, the nine subjects whose radiographs showed overinflated lungs and attenuated vessels had significantly impaired pulmonary function in comparison with 85 subjects with normal radiographs. The mean values for these nine subjects, expressed as a percentage of the mean value for subjects with normal radiographs, were: forced expiratory volume in 1 second, 75%; total lung capacity, 107%; residual volume, 143%; transpulmonary pressure at maximum inspiration, 60%; static deflation compliance, 158%; lung volume at transpulmonary pressure 10 cm H 2 O, 132%; transfer factor, 79%; and transfer factor/alveolar volume, 77%. Similar results were obtained by a second observer. Those subjects with overinflation but no vascular attenuation had significantly larger mean values for vital capacity and alveolar volume but no significant difference in total lung capacity or other tests of the mechanical properties of the lungs. Agreement on the presence of a positive sign between the two observers expressed as a percentage of those considered positive by either was 81% for overinflation and 62% for attenuated midzonal vessels. The results indicate that in groups of subjects with normal-average values of pulmonary function, the plain chest radiograph may provide information concerning pulmonary structure that is reflected in tests of function

  10. Dissipative relativistic hydrodynamics

    International Nuclear Information System (INIS)

    Imshennik, V.S.; Morozov, Yu.I.

    1989-01-01

    Using the comoving reference frame in the general non-inertial case, the relativistic hydrodynamics equations are derived with an account for dissipative effects in the matter. From the entropy production equation, the exact from for the dissipative tensor components is obtained. As a result, the closed system of equations of dissipative relativistic hydrodynamics is obtained in the comoving reference frame as a relativistic generalization of the known Navier-Stokes equations for Lagrange coordinates. Equations of relativistic hydrodynamics with account for dissipative effects in the matter are derived using the assocoated reference system in general non-inertial case. True form of the dissipative tensor components is obtained from entropy production equation. Closed system of equations for dissipative relativistic hydrodynamics is obtained as a result in the assocoated reference system (ARS) - relativistic generalization of well-known Navier-Stokes equations for Lagrange coordinates. Equation system, obtained in this paper for ARS, may be effectively used in numerical models of explosive processes with 10 51 erg energy releases which are characteristic for flashes of supernovae, if white dwarf type compact target suggested as presupernova

  11. H1N1 influenza in an Irish population: patterns of chest radiograph abnormality in patients testing positive.

    LENUS (Irish Health Repository)

    O'Sullivan, K

    2012-02-29

    The winter of 2010\\/2011 saw a second peak in the number of H1N1 cases detected in Ireland. The purpose of this study was to investigate the radiological characteristics of patients diagnosed during this period. A retrospective analysis of these cases was performed. Chest radiographs were classified as normal or abnormal. A total of 37 patients were included. Of these, 22 (59%) of chest radiographs were abnormal and 15 (41%) were normal. In the 7 paediatric patients, 4 (57%) had a perihilar distribution of disease, 2 (28%) had peripherally based disease with 1 (14%) having a mixed distribution. A series of radiographs was available for 9 patients, 6 of these showed a radiographic deterioration from the initial study. The majority of chest radiographs of patients with confirmed H1N1 infection will be abnormal. In children, disease is more likely to be perihilar in distribution. Chest radiography is an important initial investigation in patients with H1N1 infection and is useful to track progression of disease in the subset of patients requiring hospitalization for severe disease.

  12. Study on image quality of radiograph in radiographic examination for circumferential welded joint. 1. Basic study on scattered radiation in double wall exposure technique

    International Nuclear Information System (INIS)

    Kato, Kiyoshi; Ooka, Norikazu.

    1997-01-01

    Wire type Image Quality Indicators (I. Q. I.) are usually used for the evaluation of the image quality of radiographs in radiographic examinations specified in the Japanese Industrial Standard (JIS). The relationship between the sensitivity of the Image Quality Indicator and the radiographic contrast in single wall exposure technique has already been well understood. However, the relationship in double wall exposure technique is still under discussion. As a result of the fundamental experiments using flat plates, it was found in this study that the image quality of radiograph depends on the ratio of scattered X-rays generated in the focus side test plate to transmitted X-rays, and that the ratio varies in inverse proportion to the distance between the flat plates. It was also shown that the simulation method based on the Compton Effect is effective in obtaining the ratio of scattered to transmitted X-rays in the double wall exposure technique for a pipe of more than 100 mm diameter. (author)

  13. Hydraulic and hydrodynamic tests for design evaluation of research reactors fuel elements

    International Nuclear Information System (INIS)

    Kulichevsky, R.; Martin Ghiselli, A.; Fiori, J.; Yedros, P.

    2002-01-01

    During the design steps of research reactors fuel elements some tests are usually necessary to verify its design, i.e.: its hydraulic characteristics, dynamical response and structural integrity. The hydraulic tests are developed in order to know the pressure drops characteristics of different parts or elements of the prototype and of the whole fuel element. Also, some tests are carried out to obtain the velocity distribution of the coolant water across different prototype's sections. The hydrodynamic tests scopes are the assessment of the dynamical characteristics of the fuel elements and their components and its dynamical response considering the forces generated by the coolant flowing water at different flow rate conditions. Endurance tests are also necessary to qualify the structural design of the FE prototypes and their corresponding clamp tools, verifying the whole system structural integrity and wear processes influences. To carry out these tests a special test facility is needed to obtain a proper representation of the hydraulic and geometric boundary conditions of the fuel element. In some cases changes on the fuel element prototype or dummy are necessary to assure that the data results are representative of the case under study. Different kind of sensors are mounted on the test section and also on the fuel element itself when necessary. Some examples of the instrumentation used are strain gauges, displacement transducers, absolute and differential pressure transducers, pitot tubes, etc. The obtained data are, for example, plates' vibration amplitudes and frequencies, whole bundle displacement characterization, pressure drops and flow velocity measurements. The Experimental Low Pressure Loop is a hydraulic loop located at CNEA's Constituyentes Atomic Center and is the test facility where different kind of tests are performed in order to support and evaluate the design of research reactor fuel elements. A brief description of the facility, and examples of

  14. Relativistic hydrodynamics

    CERN Document Server

    Luciano, Rezzolla

    2013-01-01

    Relativistic hydrodynamics is a very successful theoretical framework to describe the dynamics of matter from scales as small as those of colliding elementary particles, up to the largest scales in the universe. This book provides an up-to-date, lively, and approachable introduction to the mathematical formalism, numerical techniques, and applications of relativistic hydrodynamics. The topic is typically covered either by very formal or by very phenomenological books, but is instead presented here in a form that will be appreciated both by students and researchers in the field. The topics covered in the book are the results of work carried out over the last 40 years, which can be found in rather technical research articles with dissimilar notations and styles. The book is not just a collection of scattered information, but a well-organized description of relativistic hydrodynamics, from the basic principles of statistical kinetic theory, down to the technical aspects of numerical methods devised for the solut...

  15. Hydrodynamic manoeuvrability data of a flatfish type AUV

    DEFF Research Database (Denmark)

    Aage, Christian; Wagner Smitt, Leif

    1994-01-01

    Hydrodynamic manoeuvrability data of the flatfish type autonomous underwater vehicle (AUV) “MARIUS” are presented. “MARIUS” was developed under the EC MAST Programme as a vehicle for seabed inspection and environmental surveys in coastal waters. The AUV has an overall length of 4.5 m and is driven...... by two propellers and four thrusters. The data comprise added mass and inertia coefficients, damping, lift and drag coefficients of the vehicle and its control surfaces, as well as resistance and propulsion characteristics. The hydrodynamic data have been determined by full scale tests, using a towing...... tank equipped with a planar motion mechanism. A few free-sailing tests have been carried out as well. Application of the data and possible improvements of the shape of the vehicle are discussed...

  16. Quality of the radiographic image in paper radiography

    International Nuclear Information System (INIS)

    Domanus, J.C.; El Fouly, H.M.

    1981-09-01

    The quality of the radiographic image was investigated by the use of standard ISO wire Image Quality Indicators and ASTM Penetrameters. 10, 20, and 30 mm thick welds on alumunium and steel plates were radiographed using X-ray machines with voltages from 35 to 300 kV. Agfa-Gevaert Structurix IC paper with Structurix IC screens Type II as well as Kodak Industrex 600 and 620 and Rapid 700 paper with Fl and F2 screens were used throughout the investigation. The results reached for radiographic paper were compared with those for a fast X-ray film (Kodak Industrex D). The results of the investigation were presented at the International Conference Joining of Metals JOM-1 in Elsinore, Denmark (9-12.8.1981) and at the Second European Conference on Non-Destructive Testing in Vienna (14-16.9.1981). The texts of both papers are reproduced in this report. (author)

  17. Recent development of hydrodynamic modeling

    Science.gov (United States)

    Hirano, Tetsufumi

    2014-09-01

    In this talk, I give an overview of recent development in hydrodynamic modeling of high-energy nuclear collisions. First, I briefly discuss about current situation of hydrodynamic modeling by showing results from the integrated dynamical approach in which Monte-Carlo calculation of initial conditions, quark-gluon fluid dynamics and hadronic cascading are combined. In particular, I focus on rescattering effects of strange hadrons on final observables. Next I highlight three topics in recent development in hydrodynamic modeling. These include (1) medium response to jet propagation in di-jet asymmetric events, (2) causal hydrodynamic fluctuation and its application to Bjorken expansion and (3) chiral magnetic wave from anomalous hydrodynamic simulations. (1) Recent CMS data suggest the existence of QGP response to propagation of jets. To investigate this phenomenon, we solve hydrodynamic equations with source term which exhibits deposition of energy and momentum from jets. We find a large number of low momentum particles are emitted at large angle from jet axis. This gives a novel interpretation of the CMS data. (2) It has been claimed that a matter created even in p-p/p-A collisions may behave like a fluid. However, fluctuation effects would be important in such a small system. We formulate relativistic fluctuating hydrodynamics and apply it to Bjorken expansion. We found the final multiplicity fluctuates around the mean value even if initial condition is fixed. This effect is relatively important in peripheral A-A collisions and p-p/p-A collisions. (3) Anomalous transport of the quark-gluon fluid is predicted when extremely high magnetic field is applied. We investigate this possibility by solving anomalous hydrodynamic equations. We found the difference of the elliptic flow parameter between positive and negative particles appears due to the chiral magnetic wave. Finally, I provide some personal perspective of hydrodynamic modeling of high energy nuclear collisions

  18. Predictive value of specific radiographic findings of disability in patients with rheumatoid arthritis

    International Nuclear Information System (INIS)

    Kaye, J.J.; Nance, E.P. Jr.; Callahan, L.F.; Pincus, T.

    1986-01-01

    This study was carried out to determine whether and to what extend radiographic erosion, joint space narrowing, and malalignment are predictive of clinical disability in patients with rheumatoid arthristis (RA). Radiographs of the hands and wrists of 224 patients with RA were scored for these radiographic parameters. To determine which of these findings best explained variation in clinical measures of disability, a series of regression analyses was performed. Malalignment scores were the best predictor of joint deformity and limitation of motion. Erosion scores were most predictive of variation in functional tests. The author concludes that specific radiographic findings of malalignment and erosion are significantly predictive of disability in patients with RA

  19. Banki-Michell Optimal Design by Computational Fluid Dynamics Testing and Hydrodynamic Analysis

    Directory of Open Access Journals (Sweden)

    Tullio Tucciarelli

    2013-04-01

    Full Text Available In hydropower, the exploitation of small power sources requires the use of small turbines that combine efficiency and economy. Banki-Michell turbines represent a possible choice for their simplicity and for their good efficiency under variable load conditions. Several experimental and numerical tests have already been designed for examining the best geometry and optimal design of cross-flow type machines, but a theoretical framework for a sequential design of the turbine parameters, taking full advantage of recently expanded computational capabilities, is still missing. To this aim, after a review of the available criteria for Banki-Michell parameter design, a novel two-step procedure is described. In the first step, the initial and final blade angles, the outer impeller diameter and the shape of the nozzle are selected using a simple hydrodynamic analysis, based on a very strong simplification of reality. In the second step, the inner diameter, as well as the number of blades and their shape, are selected by testing single options using computational fluid dynamics (CFD simulations, starting from the suggested literature values. Good efficiency is attained not only for the design discharge, but also for a large range of variability around the design value.

  20. Radiographic localization of unerupted mandibular anterior teeth.

    Science.gov (United States)

    Jacobs, S G

    2000-10-01

    The parallax method and the use of 2 radiographs taken at right angles to each other are the 2 methods generally used to accurately localize teeth. For the parallax method, the combination of a rotational panoramic radiograph with an occlusal radiograph is recommended. This combination involves a vertical x-ray tube shift. Three case reports are presented that illustrate: (1) how this combination can accurately localize unerupted mandibular anterior teeth, (2) how a deceptive appearance of the labiolingual position of the unerupted tooth can be produced in an occlusal radiograph, (3) how increasing the vertical angle of the tube for the occlusal radiograph makes the tube shift easier to discern, (4) why occlusal radiographs are preferable to periapical radiographs for tube shifts, and (5) how localization can also be carried out with 2 radiographs at right angles to each other, one of which is an occlusal radiograph taken with the x-ray tube directed along the long axis of the reference tooth.

  1. Hydrodynamic optical soliton tunneling

    Science.gov (United States)

    Sprenger, P.; Hoefer, M. A.; El, G. A.

    2018-03-01

    A notion of hydrodynamic optical soliton tunneling is introduced in which a dark soliton is incident upon an evolving, broad potential barrier that arises from an appropriate variation of the input signal. The barriers considered include smooth rarefaction waves and highly oscillatory dispersive shock waves. Both the soliton and the barrier satisfy the same one-dimensional defocusing nonlinear Schrödinger (NLS) equation, which admits a convenient dispersive hydrodynamic interpretation. Under the scale separation assumption of nonlinear wave (Whitham) modulation theory, the highly nontrivial nonlinear interaction between the soliton and the evolving hydrodynamic barrier is described in terms of self-similar, simple wave solutions to an asymptotic reduction of the Whitham-NLS partial differential equations. One of the Riemann invariants of the reduced modulation system determines the characteristics of a soliton interacting with a mean flow that results in soliton tunneling or trapping. Another Riemann invariant yields the tunneled soliton's phase shift due to hydrodynamic interaction. Soliton interaction with hydrodynamic barriers gives rise to effects that include reversal of the soliton propagation direction and spontaneous soliton cavitation, which further suggest possible methods of dark soliton control in optical fibers.

  2. Producing quality radiographic images

    International Nuclear Information System (INIS)

    Cullinan, A.M.

    1987-01-01

    This book gives an overview of physics, equipment, imaging, and quality assurance in the radiology department. The chapters are laid out with generous use of subheads to allow for quick reference, Points are illustrated with clear, uncluttered line diagrams and well-produced images. The accompanying explanations are miniature lessons by themselves. Inserted at various points throughout the text are important notes that highlight key concepts. The chapter ''Image Evaluation and Application of Radiographic Principles'' present a systematic approach to evaluating radiographs and contains several sample radiographs to illustrate the points made

  3. Hydrodynamic cavitation for sonochemical effects.

    Science.gov (United States)

    Moholkar, V S; Kumar, P S; Pandit, A B

    1999-03-01

    A comparative study of hydrodynamic and acoustic cavitation has been made on the basis of numerical solutions of the Rayleigh-Plesset equation. The bubble/cavity behaviour has been studied under both acoustic and hydrodynamic cavitation conditions. The effect of varying pressure fields on the collapse of the cavity (sinusoidal for acoustic and linear for hydrodynamic) and also on the latter's dynamic behaviour has been studied. The variations of parameters such as initial cavity size, intensity of the acoustic field and irradiation frequency in the case of acoustic cavitation, and initial cavity size, final recovery pressure and time for pressure recovery in the case of hydrodynamic cavitation, have been found to have significant effects on cavity/bubble dynamics. The simulations reveal that the bubble/cavity collapsing behaviour in the case of hydrodynamic cavitation is accompanied by a large number of pressure pulses of relatively smaller magnitude, compared with just one or two pulses under acoustic cavitation. It has been shown that hydrodynamic cavitation offers greater control over operating parameters and the resultant cavitation intensity. Finally, a brief summary of the experimental results on the oxidation of aqueous KI solution with a hydrodynamic cavitation set-up is given which supports the conclusion of this numerical study. The methodology presented allows one to manipulate and optimise of specific process, either physical or chemical.

  4. Assessment of radiation protection practices among radiographers ...

    African Journals Online (AJOL)

    Application of shielding devices such as gonad shield for protection was neglected mostly in government hospitals. Most x-ray machines were quite old and evidence of quality assurance tests performed on such machines were lacking. Conclusion: Radiographers within Lagos metropolis showed an excellent knowledge of ...

  5. Solitonic Dispersive Hydrodynamics: Theory and Observation

    Science.gov (United States)

    Maiden, Michelle D.; Anderson, Dalton V.; Franco, Nevil A.; El, Gennady A.; Hoefer, Mark A.

    2018-04-01

    Ubiquitous nonlinear waves in dispersive media include localized solitons and extended hydrodynamic states such as dispersive shock waves. Despite their physical prominence and the development of thorough theoretical and experimental investigations of each separately, experiments and a unified theory of solitons and dispersive hydrodynamics are lacking. Here, a general soliton-mean field theory is introduced and used to describe the propagation of solitons in macroscopic hydrodynamic flows. Two universal adiabatic invariants of motion are identified that predict trapping or transmission of solitons by hydrodynamic states. The result of solitons incident upon smooth expansion waves or compressive, rapidly oscillating dispersive shock waves is the same, an effect termed hydrodynamic reciprocity. Experiments on viscous fluid conduits quantitatively confirm the soliton-mean field theory with broader implications for nonlinear optics, superfluids, geophysical fluids, and other dispersive hydrodynamic media.

  6. CT colonography training for radiographers - a formal evaluation

    International Nuclear Information System (INIS)

    Haycock, A.; Burling, D.; Wylie, P.; Muckian, J.; Ilangovan, R.; Thomas-Gibson, S.

    2010-01-01

    Aims: To evaluate the efficacy of a new intensive 'hands-on' course designed to train small teams of radiographers in computed tomography colonography (CTC) technique and initial interpretation for patient triage. Materials and methods: The course comprised small-group lectures, active participation in the daily CTC service with practical technique and image interpretation training by experienced radiologists and radiographers. Evaluation was by assessment of knowledge using randomized sets of multiple choice questions (MCQ; pre/post-course), practical technique using checklists and expert global scores, and interpretation performance outcomes using randomized pre/post-course test datasets (five validated CTC examinations each). Paired t-tests were used to investigate change in performance for MCQ score and interpretation accuracy. Results: Thirteen courses with 49 participants were evaluated over 2 years. Practical skills were high, with mean (SD) checklist scores of 14/15 (0.85) and global scores of 26/30 (2.3). MCQ scores increased significantly from a mean of 59% pre-course to 69% post-course, p 10 mm) detection rates also improved significantly from 49% to 60%, p = 0.002. Conclusion: Structured training in CTC can significantly improve knowledge and interpretation skills of radiographers, while assessing safe procedural performance. Implementation of similar programmes nationally may help reduce performance gaps between centres.

  7. Radiographic Co-60 in component of heavy equipment casting

    International Nuclear Information System (INIS)

    Djoli Soembogo, Harun Al Rasyid R dan Namad Sianta

    2016-01-01

    The application of radiography using isotope Co-60 source has been used on component of heavy equipment such as component of heavy equipment casting. Components of heavy equipment casting made through metal casting of carbon steel. This study tried applying digital radiography are using isotope Co-60 sources and using scanning positive film media of Epson V700 for digitization results of conventional radiographic films. This radiography is using film AGFA D7 and Fuji 100 to obtain a contrast medium, medium sensitivity and image quality is good. The purpose radiographic Co-60 at a component of heavy equipment casting is detecting indications of the shape and type casting defects of component of heavy equipment casting thus fit for use. Radiographic test of Co-60 has been carried out on component of heavy equipment casting with single wall single image method and the results of radiographic films digitization using scanning positive film media of Epson V700 with observation parameters casting defects. Time exposure of Co-60 radiation was 10 and 15 minutes hours for metal castings of carbon steel for thickness 20.00-50.00 mm by using activity 30.05 Ci and the perpendicular distance to the source of the film is 820 mm. Scanner positive film results in the form of digital radiography which allow for the transfer of digital data or digital computerized data storage. Radiographic test results on component of heavy equipment casting with single wall single image method produce the parameter casting defect of component of heavy equipment casting in position of critical area is found shrinkage that should be repaired and in position of safety area is not found defect indication so casting defect of component of heavy equipment casting are not acceptable according to standards referenced. (author)

  8. Radiographic progession of rheumatoid arthritis

    International Nuclear Information System (INIS)

    Siozos, C.D.

    1981-01-01

    The radiographic progression of rheumatoid arthritis can be graded on a 0-IV scala. For this purpose five objective criteria are used: a) destruction, b) osteoporosis, c) narrowing of joint space, d) luxation and e) ankylosis. The grading of the radiographic progression is defined by the extent and the number of the measured alterations. The radiographic progression can be registered yearly. (orig.) [de

  9. Large-Scale Description of Interacting One-Dimensional Bose Gases: Generalized Hydrodynamics Supersedes Conventional Hydrodynamics

    Science.gov (United States)

    Doyon, Benjamin; Dubail, Jérôme; Konik, Robert; Yoshimura, Takato

    2017-11-01

    The theory of generalized hydrodynamics (GHD) was recently developed as a new tool for the study of inhomogeneous time evolution in many-body interacting systems with infinitely many conserved charges. In this Letter, we show that it supersedes the widely used conventional hydrodynamics (CHD) of one-dimensional Bose gases. We illustrate this by studying "nonlinear sound waves" emanating from initial density accumulations in the Lieb-Liniger model. We show that, at zero temperature and in the absence of shocks, GHD reduces to CHD, thus for the first time justifying its use from purely hydrodynamic principles. We show that sharp profiles, which appear in finite times in CHD, immediately dissolve into a higher hierarchy of reductions of GHD, with no sustained shock. CHD thereon fails to capture the correct hydrodynamics. We establish the correct hydrodynamic equations, which are finite-dimensional reductions of GHD characterized by multiple, disjoint Fermi seas. We further verify that at nonzero temperature, CHD fails at all nonzero times. Finally, we numerically confirm the emergence of hydrodynamics at zero temperature by comparing its predictions with a full quantum simulation performed using the NRG-TSA-abacus algorithm. The analysis is performed in the full interaction range, and is not restricted to either weak- or strong-repulsion regimes.

  10. Hydrodynamic escape from planetary atmospheres

    Science.gov (United States)

    Tian, Feng

    Hydrodynamic escape is an important process in the formation and evolution of planetary atmospheres. Due to the existence of a singularity point near the transonic point, it is difficult to find transonic steady state solutions by solving the time-independent hydrodynamic equations. In addition to that, most previous works assume that all energy driving the escape flow is deposited in one narrow layer. This assumption not only results in less accurate solutions to the hydrodynamic escape problem, but also makes it difficult to include other chemical and physical processes in the hydrodynamic escape models. In this work, a numerical model describing the transonic hydrodynamic escape from planetary atmospheres is developed. A robust solution technique is used to solve the time dependent hydrodynamic equations. The method has been validated in an isothermal atmosphere where an analytical solution is available. The hydrodynamic model is applied to 3 cases: hydrogen escape from small orbit extrasolar planets, hydrogen escape from a hydrogen rich early Earth's atmosphere, and nitrogen/methane escape from Pluto's atmosphere. Results of simulations on extrasolar planets are in good agreement with the observations of the transiting extrasolar planet HD209458b. Hydrodynamic escape of hydrogen from other hypothetical close-in extrasolar planets are simulated and the influence of hydrogen escape on the long-term evolution of these extrasolar planets are discussed. Simulations on early Earth suggest that hydrodynamic escape of hydrogen from a hydrogen rich early Earth's atmosphere is about two orders magnitude slower than the diffusion limited escape rate. A hydrogen rich early Earth's atmosphere could have been maintained by the balance between the hydrogen escape and the supply of hydrogen into the atmosphere by volcanic outgassing. Origin of life may have occurred in the organic soup ocean created by the efficient formation of prebiotic molecules in the hydrogen rich early

  11. Influence of the intergonial distance on image distortion in panoramic radiographs.

    Science.gov (United States)

    Ladeira, D B S; Cruz, A D; Almeida, S M; Bóscolo, F N

    2012-07-01

    The aim of this study was to evaluate the influence of the intergonial distance during the formation of panoramic radiographic images by means of horizontal and vertical measurements. 30 macerated mandibles were categorized into 3 different groups (n = 10) according to their intergonial distances as follows: G1, mean distance 8.2 cm, G2, mean distance 9.0 cm and G3, mean distance 9.6 cm. Three metal spheres 0.198 cm in diameter and placed at an incline using an isosceles triangle were separately placed over the internal and external surfaces of the mandibles before radiographic exposure for the purpose of taking the horizontal and vertical measurements. The occlusal planes of the mandibles were horizontally placed on the chin rest of the panoramic machine Orthopantomograph® OP 100 (Instrumentarium Imaging, Tuusula, Finland) and were then radiographed. In the panoramic radiographs, an expert radiologist measured the distances between the metal spheres in the horizontal and vertical directions using a digital caliper. The data were tabled and statistically analysed by Student's t-test and analysis of variance with Tukey post-test (α = 0.05). In all three groups magnification of the distances between spheres was observed when compared with the real distance in both horizontal and vertical measurements (p 0.05). Differences between horizontal and vertical measurements were observed in different regions in all evaluated groups (p image formation in the panoramic radiograph.

  12. A Special Pre-Service-Inspection Using Radiographic Testing(RT) for Brazing Fitting used in Aircraft Hydraulic System

    International Nuclear Information System (INIS)

    Kim, Gyu Ho

    2010-01-01

    Brazing fitting which is one of the aircraft hydraulic power system components is widely used for saving weight and achieving higher reliability. Any inherent defects or damage of fitting can cause system failure and/or physical damage of human body due to highly pressurized fluid. Radiographic testing(RT) technique and additional micro-structure investigation on cut-away surfaces have been accomplished to find out some defect-like-inhomogeneity in the fittings. The radiography results showed that some defect-like-inhomogeneity existed inside body. Additional micro-structure investigation on cut-away surface reveals that the inhomogeneity is due to internal voids. In this study, it can be is said that RT technique can be a useful tool for field acceptance test of hydraulic brazing fitting in short time

  13. The radiographer's role in child protection: Comparison of radiographers perceptions by use of focus groups

    International Nuclear Information System (INIS)

    Davis, Michaela; Reeves, Pauline

    2006-01-01

    The research presented in this paper is taken from a larger study whose aims were to devise a holistic picture of how diagnostic radiographers approach child protection issues and to explore how radiographers and other professionals see the role of radiographers in the chain of evidence in relation to child protection as this applies to children who present at the Imaging Department with suspected non-accidental injuries (NAI). A focus group methodology was used with focus groups being conducted in the United Kingdom and Republic of Ireland. The results indicated that both United Kingdom and Republic of Ireland radiographers agreed that they had a role in child protection; however, they identified a wide interpretation as to the extent of that role. Although radiographers in the United Kingdom and Republic of Ireland work within different legal systems there were themes identified which were common to both countries. Although radiographers referred to a duty to the child as to all patients, no radiographer specifically mentioned the system and child care law under which it is assumed they operate. This research revealed an area which would benefit from more detailed research using a wider audience. However, the study revealed a need for training in relation to possible NAI indicators and the correct procedure for documenting their suspicions and initiating an NAI referral

  14. Chesneys' radiographic imaging. 5. ed.

    International Nuclear Information System (INIS)

    Ball, J.; Price, T.

    1989-01-01

    This new edition of Chesney and Chesney: Radiographic Imaging has been completely written by two new authors. The book reflects the change in emphasis in radiology from photographic processes towards electronic imaging methods. There is new material on image intensifiers and television imaging, digital imaging and digital subtractions. Analyses of the various characteristics of, and defects in, images on radiographs, xeroradiographs and the television screen are included. The methods, equipment and materials used to record the cathode ray tube image are described and there is new material on the principles of alternative diagnostic imaging techniques such as ultrasound, computed tomography and radionuclide imaging which provide cathode ray tube images. The book is primarily for student radiographers studying for the Diploma of the College of Radiographers, but radiographers studying for postdiplomate qualifications such as the Higher Diploma (HDCR) will also find the book helpful. (author)

  15. Poor Utility of Gonadal Shielding for Pediatric Pelvic Radiographs.

    Science.gov (United States)

    Lee, Mark C; Lloyd, Jessica; Solomito, Matthew J

    2017-07-01

    Plain pelvic radiographs are commonly used for a variety of pediatric orthopedic disorders. Lead shielding is typically placed over the gonads to minimize radiation exposure to these sensitive tissues. However, misplaced shielding can sabotage efforts to protect patients from excessive radiation exposure either by not covering radiosensitive tissues or by obscuring anatomic areas of interest, prompting repeat radiographic examinations. The goal of this study was to determine the incidence of misplaced shielding for pelvic radiographs obtained for pediatric orthopedic evaluation. Children 8 to 16 years old who had an anteroposterior or frog lateral pelvic radiograph between 2008 and 2014 were included. A total of 3400 patients met the inclusion criteria, and 84 boys and 84 girls were randomly selected for review. For both boys and girls, the percentage of incorrectly positioned or missing shields was calculated. Chi-square testing was used to compare the frequency of missing or incorrectly placed shields between sexes and age groups. Pelvic shields were misplaced in 49% of anteroposterior and 63% of frog lateral radiographs. Shielding was misplaced more frequently for girls than for boys on frog lateral radiographs (76% vs 51%; P<.05). Pelvic bony landmarks were often obscured by pelvic shielding, with a frequency of 7% to 43%, depending on the specific landmark. The femoral head and acetabulum were obscured by shielding in up to 2% of all images. The findings suggest that accepted pelvic shielding protocols are ineffective. Consideration should be given to alternative protocols or abandonment of this practice. [Orthopedics. 2017; 40(4):e623-e627.]. Copyright 2017, SLACK Incorporated.

  16. Radiographers' commitment to continuing professional development: A single-centre evaluation

    International Nuclear Information System (INIS)

    Stevens, Barry J.

    2016-01-01

    Purpose: This study aimed to examine radiographers' commitment to continuing professional development (CPD), and to ascertain what types of activities are preferred so a model for provision of departmental activities could be developed. Methods: An online survey was used to obtain information from all departmental radiographers regarding their commitment to CPD. Statistical analysis, using Spearman's Rho and Chi-Square test, was utilised to investigate any associations. Results: All radiographers (n = 57) were invited via email. A response rate of 67% (n = 38) prevailed. Radiographers feel CPD is important and a positive correlation existed with feelings regarding compulsory CPD (r value = .718, P value = .001). Thirty-four percent had logged the SOR-recommended twelve or more pieces of CPD in the last 2 years. One to three hours a month is the preferred amount of own time radiographers are willing to dedicate. Negative correlations exist between the amount of own time radiographers are willing to commit to CPD activities and their feelings regarding compulsory CPD (r value = −.419, P value = .009), and HCPC audit (r value = −.509, P value .001). Conclusion: Although radiographers recognise the importance of CPD many spend less than four hours of their own time a month on CPD. Departmental activities should be free, short lasting, lunchtime presentations with theory presentation that encourage interaction and discussion with inclusion of practical elements. Further research investigating the barriers that prevent radiographers from partaking in CPD and the causes for insufficient CPD records is recommended. - Highlights: • The large majority of radiographers feel CPD is important or very important to them. • The majority had positive opinions regarding compulsory CPD and HCPC audit. • 50% of radiographers commit less than 4 h of their own time to CPD. • As radiographers get older they log less CPD and commit less time to CPD.

  17. Interpreting radiographs. 4. The carpus

    International Nuclear Information System (INIS)

    Burguez, P.N.

    1984-01-01

    The complexity of the carpus which has three major joints, seven or eight carpal bones and five adjacent bones, each of which articulates with one or more of the carpal elements, necessitates good quality radiographs for definitive radiographic interpretation may be extremely difficult because of the disparity between radiographic changes and obvious clinical signs and, therefore, must be discussed in the light of a thorough clinical assessment

  18. Radiographic examination protocol and patient dose in lateral cephalometric radiography in Korea

    International Nuclear Information System (INIS)

    Choi, Jin Woo

    2010-01-01

    To survey the radiographic examination protocol for lateral cephalometric radiographic examinations and to measure their patient doses in Korea and to compare the dose according to the size of hospital, the type of image receptor system, and the installation duration. The radiographic examination protocols (kVp, mA, and exposure time) for lateral cephalometric radiography were surveyed with 61 cephalometric radiographic equipments and their patient dose-area product (DAP) measured with a DAP meter (DIAMENTOR M4-KDK, PTW, Freiburg, Germany) for 51 cephalometric radiographic equipments. The radiographic examination protocols and patient doses were compared according to the size of hospital (university dental hospital, dental hospital, and dental clinic), the type of image receptor system (film-based, DR and CR type) and the installation duration, respectively. SPSS 12.0.1 for Windows (SPSS Inc., Chicago, USA) was used for independent t-test and ANOVA test. The average protocols were 77.0 kVp, 12.7 mA, 6.2 second for cephalometric radiography. The average patient dose (DAP) was 128.0 mGy cm2 and 3rd quartile dose (DAP) 161.1 mGy cm2 for cephalometric radiography for adult male. There was no statistically significant difference at average patient DAP according to the size of hospital, the type of image receptor system, and the installation duration, respectively. The average patient dose was 128.0 mGy cm2 and the third quartile patient dose 161.1 mGy cm2 for lateral cephalometric radiography for adult male in Korea.

  19. Total elbow arthroplasty: a radiographic outcome study

    Energy Technology Data Exchange (ETDEWEB)

    Bai, Xue Susan [University of Washington, Department of Radiology, Box 357115, Seattle, WA (United States); Petscavage-Thomas, Jonelle M. [Penn State Hershey Medical Center, Department of Radiology, Hershey, PA (United States); Ha, Alice S. [University of Washington, Department of Radiology, Box 354755, Seattle, WA (United States)

    2016-06-15

    Total elbow arthroplasty (TEA) is becoming a popular alternative to arthrodesis for patients with end-stage elbow arthrosis and comminuted distal humeral fractures. Prior outcome studies have primarily focused on surgical findings. Our purpose is to determine the radiographic outcome of TEA and to correlate with clinical symptoms such as pain. This is an IRB-approved retrospective review from 2005 to 2015 of all patients with semiconstrained TEA. All available elbow radiographs and clinical data were reviewed. Data analysis included descriptive statistics and Kaplan-Meier survival curves for radiographic and clinical survival. A total of 104 total elbow arthroplasties in 102 patients were reviewed; 75 % were in women and the mean patient age was 63.1 years. Mean radiographic follow-up was 826 days with average of four radiographs per patient. Seventy TEAs (67 %) developed radiographic complications, including heterotopic ossification (48 %), perihardware lucency (27 %), periprosthetic fracture (23 %), hardware subluxation/dislocation (7 %), polyethylene wear (3 %), and hardware fracture/dislodgement (3 %); 56 patients (55 %) developed symptoms of elbow pain or instability and 30 patients (30 %) underwent at least one reoperation. In patients with radiographic complications, 66 % developed elbow pain, compared to 19 % of patients with no radiologic complications (p = 0.001). Of the patients with radiographic complications, 39 % had at least one additional surgery compared to 0 % of patients without radiographic complications (p = 0.056). Radiographic complications are common in patients after total elbow arthroplasty. There is a strong positive association between post-operative radiographic findings and clinical outcome. Knowledge of common postoperative radiographic findings is important for the practicing radiologist. (orig.)

  20. A hydrodynamic formalism for Brownian systems

    International Nuclear Information System (INIS)

    Pina, E.; Rosales, M.A.

    1981-01-01

    A formal hydrodynamic approach to Brownian motion is presented and the corresponding equations are derived. Hydrodynamic quantities are expressed in terms of the physical variables characterizing the Brownian systems. Contact is made with the hydrodynamic model of Quantum Mechanics. (author)

  1. Radiographer commenting of trauma radiographs: a survey of the benefits, barriers and enablers to participation in an Australian healthcare setting

    International Nuclear Information System (INIS)

    Neep, Michael J.; Steffens, Tom; Owen, Rebecca; McPhail, Steven M.

    2014-01-01

    Radiographer abnormality detection systems that highlight abnormalities on trauma radiographs ('red dot' system) have been operating for more than 30 years. Recently, a number of pitfalls have been identified. These limitations initiated the evolution of a radiographer commenting system, whereby a radiographer provides a brief description of abnormalities identified in emergency healthcare settings. This study investigated radiographers' participation in abnormality detection systems, their perceptions of benefits, barriers and enablers to radiographer commenting, and perceptions of potential radiographer image interpretation services for emergency settings. A cross-sectional survey was implemented. Participants included radiographers from four metropolitan hospitals in Queensland, Australia. Conventional descriptive statistics, histograms and thematic analysis were undertaken. Seventy-three surveys were completed and included in the analysis (68% response rate); 30 (41%) of respondents reported participating in abnormality detection in 20% or less of examinations, and 26(36%) reported participating in 80% or more of examinations. Five overarching perceived benefits of radiographer commenting were identified: assisting multidisciplinary teams, patient care, radiographer ability, professional benefits and quality of imaging. Frequently reported perceived barriers included 'difficulty accessing image interpretation education', 'lack of time' and 'low confidence in interpreting radiographs'. Perceived enablers included 'access to image interpretation education' and 'support from radiologist colleagues'. A range of factors are likely to contribute to the successful implementation of radiographer commenting in addition to abnormality detection in emergency settings. Effective image interpretation education amenable to completion by radiographers would likely prove valuable in preparing radiographers for participation in abnormality detection and commenting systems in

  2. Hydrodynamic predictions for 5.44 TeV Xe+Xe collisions

    Science.gov (United States)

    Giacalone, Giuliano; Noronha-Hostler, Jacquelyn; Luzum, Matthew; Ollitrault, Jean-Yves

    2018-03-01

    We argue that relativistic hydrodynamics is able to make robust predictions for soft particle production in Xe+Xe collisions at the CERN Large Hadron Collider (LHC). The change of system size from Pb+Pb to Xe+Xe provides a unique opportunity to test the scaling laws inherent to fluid dynamics. Using event-by-event hydrodynamic simulations, we make quantitative predictions for several observables: mean transverse momentum, anisotropic flow coefficients, and their fluctuations. Results are shown as a function of collision centrality.

  3. Efficient inactivation of MS-2 virus in water by hydrodynamic cavitation.

    Science.gov (United States)

    Kosel, Janez; Gutiérrez-Aguirre, Ion; Rački, Nejc; Dreo, Tanja; Ravnikar, Maja; Dular, Matevž

    2017-11-01

    The aim of this study was to accurately quantify the impact of hydrodynamic cavitation on the infectivity of bacteriophage MS2, a norovirus surrogate, and to develop a small scale reactor for testing the effect of hydrodynamic cavitation on human enteric viruses, which cannot be easily prepared in large quantities. For this purpose, 3 mL scale and 1 L scale reactors were constructed and tested. Both devices were efficient in generating hydrodynamic cavitation and in reducing the infectivity of MS2 virus. Furthermore, they reached more than 4 logs reductions of viral infectivity, thus confirming the scalability of hydrodynamic cavitation for this particular application. As for the mechanism of page inactivation, we suspect that cavitation generated OH - radicals formed an advanced oxidation process, which could have damaged the host's recognition receptors located on the surface of the bacteriophage. Additional damage could arise from the high shear forces inside the cavity. Moreover, the effectiveness of the cavitation was higher for suspensions containing low initial viral titers that are in similar concentration to the ones found in real water samples. According to this, cavitation generators could prove to be a useful tool for treating virus-contaminated wastewaters in the future. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Reporting by radiographers: a policy and practice guide

    International Nuclear Information System (INIS)

    Paterson, Audrey M.; Price, Richard C.; Thomas, Adrian; Nuttall, Lorraine

    2004-01-01

    Reporting by radiographers and other non-medical staff has developed considerably in the past decade, and especially so since the College of Radiographers published its vision paper on reporting by radiographers, in 1997. It was felt necessary, therefore, to develop guidance to assist radiographers and others undertaking radiographic reporting. The guidance provided includes guidance on planning and implementing a reporting service using reporting radiographers; the education, continuing education and support required by reporting radiographers; quality and standards related to reporting; and the nature of a report. Broader issues that will need to be addressed as reporting by radiographers becomes the norm are also raised

  5. Diagnostic accuracy of radiographer reporting of computed tomography colonography examinations: A systematic review

    International Nuclear Information System (INIS)

    Meertens, R.; Brealey, S.; Nightingale, J.; McCoubrie, P.

    2013-01-01

    Computed tomography colonography (CTC) is the primary radiological test for the detection of colorectal tumours and precancerous polyps. Radiographer reporting of CTC examinations could help to improve the provision of this expanding service. We undertook a systematic review to assess the accuracy with which radiographers can provide formal written reports on intraluminal disease entities of CTC examinations compared to a reference standard. Data sources searched included online databases, peer-reviewed journals, grey literature, and reference and citation tracking. Eligible studies were assessed for bias, and data were extracted on study characteristics. Pooled estimates of sensitivities and specificities and chi-square tests of heterogeneity were calculated. Eight studies were eligible for inclusion with some risk to bias. Pooled estimates from three studies showed per patient sensitivity and specificity of reporting radiographers was 76% (95% CI: 70–80%) and 74% (95% CI: (67–80%), respectively. From seven studies, per lesion sensitivity for the detection of lesions >5 and >10 mm was 68% (95% CI: 65–71%) and 75% (95% CI: 72–79%) respectively. Pooled sensitivity for detection of lesions >5 mm in studies for which radiographers reported 50 or less training cases was 57% (95% CI: 52–61%) and more than 50 cases was 78% (95% CI: 74–81%). The current evidence does not support radiographers in a role involving the single formal written reporting of CTC examinations. Radiographers' performance, however, did appear to improve significantly with the number read. Therefore, when provided with adequate training and experience, there may be a potential role for radiographers in the reporting of CTC examinations

  6. Effects of Edentulism on Mandibular Morphology: Evaluation of Panoramic Radiographs

    Directory of Open Access Journals (Sweden)

    Rıdvan Okşayan

    2014-01-01

    Full Text Available Purpose. The objective of this study was to evaluate morphological changes of the mandible in edentulous and dentate subjects using panoramic radiographs. Materials and Methods. Panoramic radiographs were divided into the following three groups: Group I (completely edentulous group, Group II (old dentate group and Group III (young dentate group. The research parameters of gonial angle, condylar height, ramus height, ramus notch depth, and antegonial notch depth were measured on panoramic radiographs. The Kruskal-Wallis statistical test was used to determine significant differences in mandibular morphological parameters among the three groups. The Mann-Whitney U test was used to compare the subgroups. Results. Significant differences were found only in ramus height between three groups. According to the Mann-Whitney U test, a significant difference was exhibited among Groups I and II in the ramus height parameter. No significant differences were found in the gonial angle, condylar height, ramus notch depth, or antegonial notch depth when comparing the young dentate, old dentate, and completely edentulous subjects. Conclusions. Significant differences were found only in ramus height between the groups. Ramus height may be an indicator that changed by years and tooth loss. It must be considered that ramus height can be decreased in edentulism.

  7. How to fake hydrodynamic signals

    Energy Technology Data Exchange (ETDEWEB)

    Romatschke, Paul [Department of Physics, 390 UCB, University of Colorado at Boulder, Boulder, CO (United States); Center for Theory of Quantum Matter, University of Colorado, Boulder, CO 80309 (United States)

    2016-12-15

    Flow signatures in experimental data from relativistic ion collisions, are usually interpreted as a fingerprint of the presence of a hydrodynamic phase during the evolution of these systems. I review some theoretical ideas to ‘fake’ this hydrodynamic behavior in p+A and A+A collisions. I find that transverse flow and femtoscopic measurements can easily be forged through non-hydrodynamic evolution, while large elliptic flow requires some non-vanishing interactions in the hot phase.

  8. Radiographic markers for measuring tibial rotation based on CT-reconstructed radiographs. An accuracy and feasibility study

    International Nuclear Information System (INIS)

    Hakimian, David; Khoury, Amal; Mosheiff, Rami; Liebergall, Meir; Weil, Yoram A.

    2018-01-01

    Malreduction in the axial plane (malrotation) following tibial fracture surgery is often undiagnosed. A few clinical and radiographic methods have been proposed for measuring tibial rotation intraoperatively, yet have failed to match the accuracy of computed tomography (CT). The aim of this study was to develop radiographic tools for future intraoperative assessment of the tibial shaft rotation profile. The setting was a laboratory computerized analysis. Twenty lower limb CT scans were used to construct a three-dimensional (3D) model using AMIRA copyright software. A virtual 3D cylinder was implanted in the posterior condylar line and in the transmalleolar axis. The 3D models were used to simulate four standard knee and ankle plain radiographs. On each radiograph, four landmarks were depicted by two observers and their relation with the cylinder was measured and analyzed for accuracy and reproducibility. A cadaveric lower leg was implanted with two Kirschner wires. A CT scan was performed in addition to 2D fluoroscopy. The simulated radiographs and the fluoroscopy were compared for accuracy. Measurement of the landmarks showed reliability in most of the knee anteroposterior and ankle mortise radiographs (coefficients of variation < 0.01 and = 0.01) respectively. Cadaveric measurement of the landmarks using real fluoroscopy and simulated radiographs were similar. To date, no reliable and common methods have been reported for the evaluation of tibial axial rotation. We propose a model in which simple radiographic landmarks can be used to calculate a 3D coordinate system that accurately assesses the axial rotation angle of the tibial shaft. (orig.)

  9. Radiographic markers for measuring tibial rotation based on CT-reconstructed radiographs. An accuracy and feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Hakimian, David; Khoury, Amal; Mosheiff, Rami; Liebergall, Meir; Weil, Yoram A. [Hadassah Hebrew University Hospital, Department of Orthopaedics, Jerusalem (Israel)

    2018-04-15

    Malreduction in the axial plane (malrotation) following tibial fracture surgery is often undiagnosed. A few clinical and radiographic methods have been proposed for measuring tibial rotation intraoperatively, yet have failed to match the accuracy of computed tomography (CT). The aim of this study was to develop radiographic tools for future intraoperative assessment of the tibial shaft rotation profile. The setting was a laboratory computerized analysis. Twenty lower limb CT scans were used to construct a three-dimensional (3D) model using AMIRA copyright software. A virtual 3D cylinder was implanted in the posterior condylar line and in the transmalleolar axis. The 3D models were used to simulate four standard knee and ankle plain radiographs. On each radiograph, four landmarks were depicted by two observers and their relation with the cylinder was measured and analyzed for accuracy and reproducibility. A cadaveric lower leg was implanted with two Kirschner wires. A CT scan was performed in addition to 2D fluoroscopy. The simulated radiographs and the fluoroscopy were compared for accuracy. Measurement of the landmarks showed reliability in most of the knee anteroposterior and ankle mortise radiographs (coefficients of variation < 0.01 and = 0.01) respectively. Cadaveric measurement of the landmarks using real fluoroscopy and simulated radiographs were similar. To date, no reliable and common methods have been reported for the evaluation of tibial axial rotation. We propose a model in which simple radiographic landmarks can be used to calculate a 3D coordinate system that accurately assesses the axial rotation angle of the tibial shaft. (orig.)

  10. Significance of radiographic abnormalities in patients with tibial stress injuries: correlation with magnetic resonance imaging

    International Nuclear Information System (INIS)

    Kijowski, Richard; Choi, James; Smet, Arthur de; Mukharjee, Rajat

    2007-01-01

    The objective was to correlate radiographic findings with magnetic resonance imaging (MRI) findings in patients with suspected tibial stress injuries in order to determine the significance of radiographic signs of stress injury in these individuals. The study group consisted of 80 patients with suspected tibial stress injuries who underwent a radiographic and MR examination of the tibia. Nineteen patients had bilateral involvement. Thus, a total of 99 tibias were evaluated. All radiographs and MR examinations were retrospectively reviewed, 1 month apart, in consensus by two musculoskeletal radiologists. The radiographs were reviewed without knowledge of the site of the clinical symptoms. Fisher's exact tests were used to determine the association between a positive radiograph and the presence of various MRI signs of a high-grade stress injury. There was a strong association between the presence of periosteal reaction on radiographs at the site of the clinical symptoms and a Fredericson grade 4 stress injury on MRI. The presence of periosteal reaction on radiographs at the site of clinical symptoms is predictive of a high-grade stress injury by MRI criteria. (orig.)

  11. Radiographic cup anteversion measurement corrected from pelvic tilt.

    Science.gov (United States)

    Wang, Liao; Thoreson, Andrew R; Trousdale, Robert T; Morrey, Bernard F; Dai, Kerong; An, Kai-Nan

    2017-11-01

    The purpose of this study was to develop a novel technique to improve the accuracy of radiographic cup anteversion measurement by correcting the influence of pelvic tilt. Ninety virtual total hip arthroplasties were simulated from computed tomography data of 6 patients with 15 predetermined cup orientations. For each simulated implantation, anteroposterior (AP) virtual pelvic radiographs were generated for 11 predetermined pelvic tilts. A linear regression model was created to capture the relationship between radiographic cup anteversion angle error measured on AP pelvic radiographs and pelvic tilt. Overall, nine hundred and ninety virtual AP pelvic radiographs were measured, and 90 linear regression models were created. Pearson's correlation analyses confirmed a strong correlation between the errors of conventional radiographic cup anteversion angle measured on AP pelvic radiographs and the magnitude of pelvic tilt (P cup anteversion angle from the influence of pelvic tilt. The current method proposes to measure the pelvic tilt on a lateral radiograph, and to use it as a correction for the radiographic cup anteversion measurement on an AP pelvic radiograph. Thus, both AP and lateral pelvic radiographs are required for the measurement of pelvic posture-integrated cup anteversion. Compared with conventional radiographic cup anteversion, the errors of pelvic posture-integrated radiographic cup anteversion were reduced from 10.03 (SD = 5.13) degrees to 2.53 (SD = 1.33) degrees. Pelvic posture-integrated cup anteversion measurement improves the accuracy of radiographic cup anteversion measurement, which shows the potential of further clarifying the etiology of postoperative instability based on planar radiographs. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  12. Radiographic examination for successful dental implant

    International Nuclear Information System (INIS)

    Lee, Sam Sun; Choi, Soon Chul

    2005-01-01

    Recently implant has become an important field in dental clinic. Radiographic examination of pre- and post-operation is essential for successful treatment. Clinicians should have knowledge about the purpose of the radiographic examination, suitable imaging modality for the cases, anatomic landmarks of tooth and jaw bone, advantage and limitation of panoramic radiographic examination for implant, principle and interpretation of cross-sectional imaging, bone mineral density, post-operative radiographic examination. This paper will be helpful to get above information for dentists who want to do dental implant successfully.

  13. Validity of radiographic assessment of ankylosis

    International Nuclear Information System (INIS)

    Stenvik, A.; Beyer-Olsen, E.; Aabyholm, F.; Haanaes, H.R.; Gerner, N.W.

    1990-01-01

    The accuracy and sensitivity of radiographic assessments of reactive processes in dental tissues were evaluated by comparison of radiographs and histologic sections. Experimental lesions inflicted on the roots of 10 monkey incisors had been observed by means of serially obtained radiographs over a period of 315 to 370 days. The material was used for evaluation of radiographic assessment of ankylosis. For comparative purposes, assessment of the experimental lesion penetrating to the pulp and periapical radiolucency was added. True and falsely positive or negative recordings formed the basis for calculation of the accuracy and sensitivity of the radiographic assessment. The sensitivity, or the obsevers ability to detect the actual changes, was high for pulp penetration, intermediate for inflammation, and low for ankylosis. 6 refs., 3 figs., 2 tabs

  14. Effectiveness Of Plain Shoulder Radiograph In Detecting Degenerate Rotator Cuff Tears.

    Science.gov (United States)

    Hussain, Adnan; Muzzammil, Muhammad; Butt, Faisal; Valsamis, Epaminondas Markos; Dwyer, Amitabh J

    2018-01-01

    Studies have demonstrated radiographic findings of sclerosis and cortical irregularity at the greater tuberosity can suggest a rotator cuff tear. Plain radiographs are the most easily attainable first-line investigations in evaluating shoulder injuries. This study determines the effectiveness in predicting degenerate rotator cuff tears by detecting radiographic changes on shoulder x-rays. Retrospective cross-sectional study with a consecutive series of patients conducted in Hinchingbrooke Hospital, Huntingdon, United Kingdom from January 2015 to June 2017. Anteroposterior shoulder radiographs of 150 symptomatic patients who underwent shoulder arthroscopy were independently analysed by surgeons who were blinded from the arthroscopic results. Patients aged fewer than 30 and over 70 years were excluded. Patients with advanced osteoarthritis and cuff tear arthropathy evident on x-rays were also excluded. Sixty-five patients included in the study had rotator cuff tears on arthroscopy. Radiographic changes were correlated with arthroscopic findings to determine this test's ability to predict degenerate rotator cuff tears. When both cortical irregularity and sclerosis were present on the plain radiograph, these signs had a sensitivity of 78.8% [95% CI 65.7, 87.8%] and specificity 77.4% [95% CI 67.2, 85.0%] with a positive predictive value of 68.3%, using contingency table analysis. The presence of cortical irregularity was found to be a better predictor of a tear as compared to sclerosis. This study concludes that plain radiograph are good modality for initial evaluation of rotator cuff tears and detecting when both cortical irregularity and sclerosis. Consideration of these radiographic findings serves as a useful adjunct in diagnostic workup and can guide subsequent investigations and treatment when evaluating rotator cuff tears of the shoulder.

  15. Chest radiographic staging in allergic bronchopulmonary aspergillosis: relationship with immunological findings.

    LENUS (Irish Health Repository)

    Kiely, J L

    2012-02-03

    The question of whether a chest radiographic severity staging system could be correlated with standard blood\\/serum diagnostic indices in allergic bronchopulmonary aspergillosis (ABPA) was addressed in 41 patients. Asthma and positive Aspergillus fumigatus (AF) serology were considered essential diagnostic inclusion criteria. Eosinophil count, serum immunoglobulin (Ig)E and immediate skin hypersensitivity were also tested to grade patients as "definite" or "likely" ABPA. Definite cases had all five of these factors present, whereas likely cases had three or more. Chest radiographs were examined by experienced radiologists blinded to the clinical data. The six-stage radiographic score (0-5) was based on the severity and duration of changes seen: stage 0: normal; stage 1: transient hyperinflation; stage 2: transient minor changes; stage 3: transient major changes; stage 4: permanent minor changes; and stage 5: permanent major changes. Significant positive correlations (p<0.05) were observed between peak AF titres (expressed as an index), peak eosinophil count and radiographic severity stage. When considered as subgroups, these correlations approached, but did not reach, significance for the group with "likely" ABPA (n=28), but in the group with definite ABPA (n=13), there was a high correlation between radiographic score and peak AF index (r=0.59), as well as peak eosinophil count (r=0.62). This study suggests that the peak Aspergillus fumigatus index and eosinophil counts correlate best with the severity of radiographic stages in allergic bronchopulmonary aspergillosis. This chest radiographic staging system may be useful in the clinical assessment and management of patients with allergic bronchopulmonary aspergillosis, particularly in those patients with more severe radiographic stages.

  16. Interphalangeal Osteoarthritis Radiographic Simplified (iOARS) score: a radiographic method to detect osteoarthritis of the interphalangeal finger joints based on its histopathological alterations.

    Science.gov (United States)

    Sunk, Ilse-Gerlinde; Amoyo-Minar, Love; Stamm, Tanja; Haider, Stefanie; Niederreiter, Birgit; Supp, Gabriela; Soleiman, Afschin; Kainberger, Franz; Smolen, Josef S; Bobacz, Klaus

    2014-11-01

    To develop a radiographic score for assessment of hand osteoarthritis (OA) that is based on histopathological alterations of the distal (DIP) and proximal (PIP) interphalangeal joints. DIP and PIP joints were obtained from corpses (n=40). Plain radiographies of these joints were taken. Joint samples were prepared for histological analysis; cartilage damage was graded according to the Mankin scoring system. A 2×2 Fisher's exact test was applied to define those radiographic features most likely to be associated with histological alterations. Receiver operating characteristic curves were analysed to determine radiographic thresholds. Intraclass correlation coefficients (ICC) estimated intra- and inter-reader variability. Spearman's correlation was applied to examine the relationship between our score and histopathological changes. Differences between groups were determined by a Student's t test. The Interphalangeal Osteoarthritis Radiographic Simplified (iOARS) score is presented. The score is based on histopathological changes of DIP and PIP joints and follows a simple dichotomy whether OA is present or not. The iOARS score relies on three equally ranked radiographic features (osteophytes, joint space narrowing and subchondral sclerosis). For both DIP and PIP joints, the presence of one x-ray features reflects interphalangeal OA. Sensitivity and specificity for DIP joints were 92.3% and 90.9%, respectively, and 75% and 100% for PIP joints. All readers were able to reproduce their own readings in DIP and PIP joints after 4 weeks. The overall agreement between the three readers was good; ICCs ranged from 0.945 to 0.586. Additionally, outcomes of the iOARS score in a hand OA cohort revealed a higher prevalence of interphalangeal joint OA compared with the Kellgren and Lawrence score. The iOARS score is uniquely based on histopathological alterations of the interphalangeal joints in order to reliably determine OA of the DIP and PIP joints radiographically. Its high

  17. Porosity. ''The good, the bad and ugly'' of Radiographic Testing

    International Nuclear Information System (INIS)

    Vaughan, Hugo

    2016-01-01

    ''Radiographic Testing is a NDT method to detect inherent volumetric discontinuities in materials such as castings and welds'' A common type of discontinuity found and most often misinterpreted and evaluated is rounded indications, whether isolated, aligned or clustered. This paper addresses the acceptance criteria of rounded indications based on various codes and standards and intends to lay at rest the confusion related to this type of discontinuity. The following are important considerations: 1. Interpretation of rounded indications based on codes and standards used in the various sectors of NDT. 2. What types of discontinuities can be regarded as rounded indications? 3. What discontinuity sizes can be regarded as relevant discontinuities? 4. What are the acceptance and rejection criteria for relevant rounded indications 5. Compiling relevant student assignments to facilitate the proper understanding of this aspect.

  18. The Society and College of Radiographers - 60 years on

    International Nuclear Information System (INIS)

    Kinloch, J.

    1980-01-01

    The year 1980 heralded the Diamond Jubilee of the Society and College of Radiographers. A personal review of the history of the Society and College and its aims over the past sixty years is given. The review commences with the formation of the Society in 1920 and follows its testing time throughout the twenties, the expansion of its activities in the period up to the Second World War, its wartime function, its postwar activities particularly in relation to radiographers' conditions of service and salaries and finally the events of the 60's to the present day. (U.K.)

  19. 21 CFR 892.1840 - Radiographic film.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic film. 892.1840 Section 892.1840 Food... DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1840 Radiographic film. (a) Identification. Radiographic film is a device that consists of a thin sheet of radiotransparent material coated on one or both...

  20. Radiographic evaluation of cases referred for surgical endodontics

    NARCIS (Netherlands)

    Doornbusch, H.; Broersma, L.; Boering, G.; Wesselink, P.R.

    Aim The aim of this study is to test the hypothesis that more patients with failed root-canal treatment or other endodontic problems are referred for periradicular surgery rather than nonsurgical re-treatment. Methodology Three sets of 100 periapical radiographs representing typical cases referred

  1. Radiographic bone loss in a Scottish non-smoking Type 1 Diabetes mellitus population; a Bitewing Radiographic Study.

    Science.gov (United States)

    Plessas, Anastasios; Robertson, Douglas P; Hodge, Penny J

    2018-05-15

    The dental complications of uncontrolled diabetes include reduced salivary flow rate, candidiasis and periodontal manifestations. A recent meta-analysis concluded that diabetes patients have a significantly higher severity, but not extent, of destructive periodontal disease than non-diabetes people. The authors reported that most type-1 diabetes studies using dental radiographic data have not controlled for confounding factors such as smoking. The aim of this cross-sectional study was to compare radiographic alveolar bone loss between type 1 diabetes (T1DM) and non-diabetes (NDM) participants in a Scottish non-smoking population. Digital bitewing radiographs for 174 Scottish adult never or ex-smoker (> 5 years) participants (108 T1DM, 66 NDS), recruited from outpatient clinics throughout Greater Glasgow and Clyde, were included in the analysis. A single blinded, trained and calibrated examiner recorded the radiographic bone loss seen on bitewing radiographs using the digital screen caliper. The bone loss was measured as the distance between the cemento-enamel junction (CEJ) and the deepest radiographic alveolar bone margin interproximally of each tooth. T1DM participants had more radiographic alveolar bone loss throughout the all teeth measured (median:1.27 mm vs 1.06 mm, P diabetes subjects. Patients suffering from type 1 diabetes are at higher risk of periodontitis even when controlling for multiple possible confounding factors and this difference can be detected on routine dental radiographs at an early stage. These data confirm radiographically the previously reported association between T1DM and periodontal bone loss. This article is protected by copyright. All rights reserved. © 2018 American Academy of Periodontology.

  2. Hydrodynamical description of collective flow

    OpenAIRE

    Huovinen, Pasi

    2003-01-01

    I review how hydrodynamical flow is related to the observed flow in ultrarelativistic heavy ion collisions and how initial conditions, equation of state and freeze-out temperature affect flow in hydrodynamical models.

  3. Biomimetic shark skin: design, fabrication and hydrodynamic function.

    Science.gov (United States)

    Wen, Li; Weaver, James C; Lauder, George V

    2014-05-15

    Although the functional properties of shark skin have been of considerable interest to both biologists and engineers because of the complex hydrodynamic effects of surface roughness, no study to date has successfully fabricated a flexible biomimetic shark skin that allows detailed study of hydrodynamic function. We present the first study of the design, fabrication and hydrodynamic testing of a synthetic, flexible, shark skin membrane. A three-dimensional (3D) model of shark skin denticles was constructed using micro-CT imaging of the skin of the shortfin mako (Isurus oxyrinchus). Using 3D printing, thousands of rigid synthetic shark denticles were placed on flexible membranes in a controlled, linear-arrayed pattern. This flexible 3D printed shark skin model was then tested in water using a robotic flapping device that allowed us to either hold the models in a stationary position or move them dynamically at their self-propelled swimming speed. Compared with a smooth control model without denticles, the 3D printed shark skin showed increased swimming speed with reduced energy consumption under certain motion programs. For example, at a heave frequency of 1.5 Hz and an amplitude of ± 1 cm, swimming speed increased by 6.6% and the energy cost-of-transport was reduced by 5.9%. In addition, a leading-edge vortex with greater vorticity than the smooth control was generated by the 3D printed shark skin, which may explain the increased swimming speeds. The ability to fabricate synthetic biomimetic shark skin opens up a wide array of possible manipulations of surface roughness parameters, and the ability to examine the hydrodynamic consequences of diverse skin denticle shapes present in different shark species. © 2014. Published by The Company of Biologists Ltd.

  4. Reproductive health of male radiographers

    International Nuclear Information System (INIS)

    Shakhatreh, Farouk M.

    2001-01-01

    To compare certain reproductive health problems reported in 2 groups of males, one of which was exposed to x-ray radiation (radiographers) and the other group that was not exposed to x-ray radiation. The reproductive health problems were miscarriage, congenital anomalies, still births and infertility. Two groups of men were selected (90 in each group). The first group consisted of radiographers and the other groups consisted of men not exposed to x-ray radiation. The 2 groups were matched for age and source. Relative risk, attributable risk percentage and level of significance were calculated. Incidence rate of reproductive health problems was increasing with the increase in duration of exposure to x-ray radiation ranging between 17% (for those exposed for 1-5 years) to 91% (for those exposed for more than 15 years). There were significant associations between exposure to radiation and miscarriage (relative risk = 1.67, attributable risk percentage = 40%), congenital anomalies (relative risk = 10, attributable risk percentage 90%), still birth (relative risk = 7, attributable risk percentage = 86%), and infertility (relative risk = 4.5, attributable risk = 78%). The incidence rates of reproductive health problems reported by male radiographers were significantly higher than that reported by the non exposed group and higher than the incidence rates reported in community-based studies in Jordan. The incidence rates of fetal death (miscarriage and stillbirth together) and infertility reported by our radiographers were higher than had been reported by the British radiographers. An immediate plan of action is needed to protect our radiographers. Further studies are needed in this field taking into account all extraneous variables that may affect the reproductive health of radiographers. (author)

  5. Building Of Training Program Of Non-Destructive Testing For Concrete Structures (Part 1: Radiographic testing; Ultrasonic pulse velocity measurement; Nuclear moisture-density gauge)

    International Nuclear Information System (INIS)

    Nguyen Le Son; Phan Chanh Vu; Pham The Hung; Vu Huy Thuc

    2007-01-01

    Non-destructive testing methods (NDT) have been identified as a strong candidate for remote sensing of concrete structures over recent years. This has accelerated the powerful development of the NDT techniques in Vietnam. Hence, there is an urgent need to promote the awareness of NDT methods which could give an improved estimate of the condition concrete. Building of training program of non-destructive testing for concrete structures is a necessary duty, in aiming to build a unified training program, possibly satisfying the requirements on training as well as researching. Under the framework of the basic VAEC project (CS/07/02-03), a training program for the first 03 NDT methods: 1. Radiographic testing; 2. Ultrasonic pulse velocity measurement; 3. Nuclear moisture- density gauge was prepared. The main products of this project include: 1. Set out 03 training notes for 03 methods; 2. Set out the practical exercises to train for 03 methods; 3. Editing a set of examination questions in aiming to familiarize with various questions in 03 trained methods; 4. Fabricating practical test specimens to demonstrate for 03 techniques. (author)

  6. Evaluation of a radiographic method to detect tibial dyschondroplasia lesions in broilers

    Directory of Open Access Journals (Sweden)

    K Pelicia

    2012-06-01

    Full Text Available This study aimed at developing radiographic techniques for the early detection of dyschondroplastic lesions in the tibia of broilers. The experiment was carried out at the facilities of UNIFOR/MG and Formiga and UNIFENAS/ Alfenas with 420 one-day-old male Cobb broilers. At 20 days of age, all birds were radiographed and identified with an alpha-numeric metal ring in the right leg. At 40 days of age, 42 broilers previously selected as a function of bone mineral density and lesion thickness scores were again radiographed and scored, and then sacrificed. Their right tibia was removed for gross and histological examination of the growth plate. The results showed that radiographic techniques are correlated with gross and histological examination and that there was no significant differences among techniques (P>0.05. it was concluded that the use of radiographic examination to identify tibial dyschondroplasia in broilers precludes the use of bone mineral density to diagnose this condition. The non-parametric statistical Chi-square test at 5% significance level was used to analyze the results.

  7. Accuracy of radiographer reporting of paediatric brain CT

    International Nuclear Information System (INIS)

    Brandt, Andrew; Louw, Brand; Dekker, Gerrit; Andronikou, Savvas; Wieselthaler, Nicki; Kilborn, Tracy; Bertelsman, Jessica; Dreyer, Catherine

    2007-01-01

    Radiographer reporting has been studied for plain films and for ultrasonography, but not in paediatric brain CT in the emergency setting. To study the accuracy of radiographer reporting in paediatric brain CT. We prospectively collected 100 paediatric brain CT examinations. Films were read from hard copies using a prescribed tick sheet. Radiographers with 12 years' and 3 years' experience, respectively, were blinded to the history and were not trained in diagnostic film interpretation. The radiographers' results were compared with those of a consultant radiologist. Three categories were defined: abnormal scans, significant abnormalities and insignificant abnormalities. Both radiographers had an accuracy of 89.5% in reading a scan correctly as abnormal, and radiographer 1 had a sensitivity of 87.8% and radiographer 2 a sensitivity of 96%. Radiographer 1 had an accuracy in detecting a significant abnormality of 75% and radiographer 2 an accuracy of 48.6%, and the sensitivities for this category were 61.6% and 52.9%, respectively. Results for detecting the insignificant abnormalities were poorer. Selected radiographers could play an effective screening role, but lacking the sensitivity required for detecting significant abnormality, they could not be the final diagnostician. We recommend that the study be repeated after both radiographers have received formal training in interpretation of paediatric brain CT. (orig.)

  8. An exploratory study of radiographer's perceptions of radiographer commenting on musculo-skeletal trauma images in rural community based hospitals

    International Nuclear Information System (INIS)

    Howard, Morag L.

    2013-01-01

    Aim: This study sought to explore the perceptions of community hospital based radiographers in North East Scotland regarding the practice of radiographer commenting on musculo-skeletal trauma images. Method: A purposive sample of radiographers (n = 8) were recruited from community hospitals throughout the North-east of Scotland. A qualitative, exploratory study was conducted employing semi-structured interviews consisting of one focus group and two individual interviews. The interviews were audio recorded and transcribed in full to allow thematic analysis of the data using a framework adapted from Pope and Mays (2006). Main findings: This study revealed that the practice of radiographer commenting in the community provides a valuable front line opinion on musculo-skeletal trauma image appearances to enhance diagnostic outcomes for patients and streamline their care pathway. The appreciation shown from inter-professional colleagues for this practice induced feelings of professional pride and job satisfaction in the sample group. All participants expressed a desire to undertake additional training to allow progression from radiographer commenting to radiographer reporting of musculo-skeletal trauma images. Perceived barriers to the practice of radiographer commenting were time constraints and a lack of support with regards to continuing professional development (CPD) opportunities and mentorship from radiology colleagues. Conclusion: The practice of radiographer commenting in the community setting should be supported by ongoing training, and radiologist involvement in mentoring could provide radiographers with a valuable support mechanism. The voice of all radiographers regarding this extended role must be heard by professional leaders to ensure that the skills and education required for radiographer commenting are provided and subsequent patient care is not compromised

  9. Hydrodynamic Study Of Column Bioleaching Processes

    Directory of Open Access Journals (Sweden)

    Sadowski Zygmunt

    2015-06-01

    Full Text Available The modelling of flow leaching solution through the porous media has been considered. The heap bioleaching process can be tested using the column experimental equipment. This equipment was employed to the hydrodynamic studies of copper ore bioleaching. The copper ore (black shale ore with the support, inertial materials (glass small balls and polyethylene beads was used to the bioleaching tests. The packed beds were various composition, the ore/support ratio was changed. The correlation between the bed porosity and bioleaching kinetics, and copper recovery was investigated.

  10. Assessing the Hydrogeomorphic Effects of Environmental Flows using Hydrodynamic Modeling.

    Science.gov (United States)

    Gregory, Angela; Morrison, Ryan R; Stone, Mark

    2018-04-13

    Water managers are increasingly using environmental flows (e-flows) as a tool to improve ecological conditions downstream from impoundments. Recent studies have called for e-flow approaches that explicitly consider impacts on hydrogeomorphic processes when developing management alternatives. Process-based approaches are particularly relevant in river systems that have been highly modified and where water supplies are over allocated. One-dimensional (1D) and two-dimensional (2D) hydrodynamic models can be used to resolve hydrogeomorphic processes at different spatial and temporal scales to support the development, testing, and refinement of e-flow hypotheses. Thus, the objective of this paper is to demonstrate the use of hydrodynamic models as a tool for assisting stakeholders in targeting and assessing environmental flows within a decision-making framework. We present a case study of e-flows on the Rio Chama in northern New Mexico, USA, where 1D and 2D hydrodynamic modeling was used within a collaborative process to implement an e-flow experiment. A specific goal of the e-flow process was to improve spawning habitat for brown trout by flushing fine sediments from gravel features. The results revealed that the 2D hydrodynamic model provided much greater insight with respect to hydrodynamic and sediment transport processes, which led to a reduction in the recommended e-flow discharge. The results suggest that 2D hydrodynamic models can be useful tools for improving process understanding, developing e-flow recommendations, and supporting adaptive management even when limited or no data are available for model calibration and validation.

  11. Radiograph identifying means

    International Nuclear Information System (INIS)

    Sheldon, A.D.

    1983-01-01

    A flexible character-indentable plastics embossing tape is backed by and bonded to a lead strip, not more than 0.025 inches thick, to form a tape suitable for identifying radiographs. The lead strip is itself backed by a relatively thin and flimsy plastics or fabric strip which, when removed, allows the lead plastic tape to be pressure-bonded to the surface to be radiographed. A conventional tape-embossing gun is used to indent the desired characters in succession into the lead-backed tape, without necessarily severing the lead; and then the backing strip is peeled away to expose the layer of adhesive which pressure-bonds the indented tape to the object to be radiographed. X-rays incident on the embossed tape will cause the raised characters to show up dark on the subsequently-developed film, whilst the raised side areas will show up white. Each character will thus stand out on the developed film. (author)

  12. Digital processing of radiographic images

    Science.gov (United States)

    Bond, A. D.; Ramapriyan, H. K.

    1973-01-01

    Some techniques are presented and the software documentation for the digital enhancement of radiographs. Both image handling and image processing operations are considered. The image handling operations dealt with are: (1) conversion of format of data from packed to unpacked and vice versa; (2) automatic extraction of image data arrays; (3) transposition and 90 deg rotations of large data arrays; (4) translation of data arrays for registration; and (5) reduction of the dimensions of data arrays by integral factors. Both the frequency and the spatial domain approaches are presented for the design and implementation of the image processing operation. It is shown that spatial domain recursive implementation of filters is much faster than nonrecursive implementations using fast fourier transforms (FFT) for the cases of interest in this work. The recursive implementation of a class of matched filters for enhancing image signal to noise ratio is described. Test patterns are used to illustrate the filtering operations. The application of the techniques to radiographic images of metallic structures is demonstrated through several examples.

  13. Agreement Between Panoramic and Lateral Cephalometric Radiographs for Measuring the Gonial Angle

    International Nuclear Information System (INIS)

    Zangouei-Booshehri, Maryam; Aghili, Hossein-Agha; Abasi, Mojtaba; Ezoddini-Ardakani, Fatemeh

    2012-01-01

    The gonial angle is one of the most important measurements required for orthodontic treatment and orthognathic surgery. It is difficult to determine the accurate measurement of each gonial angle on cephalometric radiographs because of superimposition of the left and right angles. The aim of the present study was to determine the right and left gonial angles on panoramic radiographs and to compare them with an evaluated cephalometric sample. A total of 80 panoramic and 80 cephalometric radiographs were obtained from 6 to 12-year-old children and the gonial angle was determined by the tangent of the inferior border of the mandible and the most distal aspect of the ascending ramus and the condyleon both panoramic and cephalometric radiographs. We used Pearson’s correlation coefficient and paired t-test for comparison. The mean gonial angle was 127.07 ± 6.10 and 127.5 ± 6.67 degrees on panoramic and cephalometric radiographs, respectively. There was no statistically significant difference between the measured gonial angles on panoramic and cephalometric radiographs and also no difference between the right and left (both Ps = 0.18) The value of the gonial angle measured on panoramic radiography was the same as that measured on the routinely used cephalometric radiography

  14. Hydrodynamics and stellar winds an introduction

    CERN Document Server

    Maciel, Walter J

    2014-01-01

    Stellar winds are a common phenomenon in the life of stars, from the dwarfs like the Sun to the red giants and hot supergiants, constituting one of the basic aspects of modern astrophysics. Stellar winds are a hydrodynamic phenomenon in which circumstellar gases expand towards the interstellar medium. This book presents an elementary introduction to the fundamentals of hydrodynamics with an application to the study of stellar winds. The principles of hydrodynamics have many other applications, so that the book can be used as an introduction to hydrodynamics for students of physics, astrophysics and other related areas.

  15. Imaging of juvenile spondyloarthritis. Part I: Classifications and radiographs

    Directory of Open Access Journals (Sweden)

    Iwona Sudoł-Szopińska

    2017-09-01

    Full Text Available Juvenile spondyloarthropathies are manifested mainly by symptoms of peripheral arthritis and enthesitis. By contrast with adults, children rarely present with sacroiliitis and spondylitis. Imaging and laboratory tests allow early diagnosis and treatment. Conventional radiographs visualize late inflammatory lesions and post-inflammatory complications. Early diagnosis is possible with the use of ultrasonography and magnetic resonance imaging. The first part of the article presents classifications of juvenile spondyloarthropathies and discusses their radiographic presentation. Typical radiographic features of individual types of juvenile spondyloarthritis are listed (including ankylosing spondylitis, juvenile psoriatic arthritis, reactive arthritis and arthritis in the course of inflammatory bowel diseases. The second part will describe changes visible on ultrasonography and magnetic resonance imaging. In patients with juvenile spondyloarthropathies, these examinations are conducted to diagnose inflammatory lesions in peripheral joints, tendon sheaths, tendons and bursae. Moreover, magnetic resonance imaging also visualizes early inflammatory changes in the axial skeleton and subchondral bone marrow edema, which is considered an early sign of inflammation.

  16. An introduction to relativistic hydrodynamics

    Energy Technology Data Exchange (ETDEWEB)

    Font, Jose A [Departamento de AstronomIa y AstrofIsica, Universidad de Valencia, Dr. Moliner 50, 46100 Burjassot (Valencia) (Spain)

    2007-11-15

    We review formulations of the equations of (inviscid) general relativistic hydrodynamics and (ideal) magnetohydrodynamics, along with methods for their numerical solution. Both systems can be cast as first-order, hyperbolic systems of conservation laws, following the explicit choice of an Eulerian observer and suitable fluid and magnetic field variables. During the last fifteen years, the so-called (upwind) high-resolution shock-capturing schemes based on Riemann solvers have been successfully extended from classical to relativistic fluid dynamics, both special and general. Nowadays, general relativistic hydrodynamical simulations in relativistic astrophysics are routinely performed, particularly within the test-fluid approximation but also for dynamical spacetimes. While such advances also hold true in the case of the MHD equations, the astrophysical applications investigated so far are still limited, yet the field is bound to witness major developments in the near future. The article also presents a brief overview of numerical techniques, providing state-of-the-art examples of their applicability to general relativistic fluids and magneto-fluids in characteristic scenarios of relativistic astrophysics.

  17. High resolution CT in children with cystic fibrosis: correlation with pulmonary functions and radiographic scores

    International Nuclear Information System (INIS)

    Demirkazik, Figen Basaran; Ariyuerek, O. Macit; Oezcelik, Ugur; Goecmen, Ayhan; Hassanabad, Hossein K.; Kiper, Nural

    2001-01-01

    Objective: To compare the high resolution CT (HRCT) scores of the Bhalla system with pulmonary function tests and radiographic and clinical points of the Shwachman-Kulczycki clinical scoring system. Methods: HRCT of the chest was obtained in 40 children to assess the role of HRCT in evaluating bronchopulmonary pathology in children with cystic fibrosis (CF). The HRCT severity scores of the Bhalla system were compared with chest radiographic and clinical points of the Shwachman-Kulczycki scoring system and pulmonary function tests. Only 14 of the patients older than 6 years cooperated with spirometry. Results: HRCT scores correlated well with radiographic points (r=0.80, P 1 (r=0.66, P=0.01). Although radiographic points correlated significantly with FVC (r=0.61, P=0.02) and FEV 1 (r=0.56, P=0.04), HRCT provides a more precise scoring than the chest X-ray. Conclusion: The HRCT scoring system may provide a sensitive method of monitoring pulmonary disease status and may replace the radiographic scoring in the Shwachman-Kulczycki system. It may be helpful especially in follow-up of small children too young to cooperate with spirometry

  18. Legalities of the radiograph

    International Nuclear Information System (INIS)

    Bundy, A.L.

    1988-01-01

    The radiograph itself plays a major role in medical malpractice cases. Also, many questions arise concerning the rights to and storage of x-ray films. These issues are addressed in this chapter. To keep the terminology simple, the word radiograph represents all imaging documentation on hard copy film (x-rays, nuclear medicine, computer-assisted studies, ultrasound, and magnetic resonance imaging)

  19. Design and evaluation of learning strategies for a group of radiographers in radiostereometric analysis (RSA).

    Science.gov (United States)

    Muharemovic, O; Troelsen, A; Thomsen, M G; Kallemose, T; Gosvig, K K

    2017-11-01

    The purpose of this study was to design and evaluate a radiostereometric analysis (RSA) program aimed at radiographers in order to increase their cognitive and practical skills, thereby increasing image quality and minimizing exposure repetition. Twenty radiographers were randomized into two identically sized study groups. Training consisted of a theoretical and practical workshop using a phantom. Tests were performed to compare the effect of training to nontraining, and the effect of time duration on the maintenance of RSA skills. The effect of training was measured by a written test and three defined parameters influencing image quality. Group A reduced significantly (p RSA X-ray training program where radiographers significantly improve their theoretical and practical skills in centering the CP closer to the CCF, NB and RP. A duration of up to two months after training does not influence the quality of participants' performance. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  20. Consultant breast radiographers: Where are we now?

    International Nuclear Information System (INIS)

    Rees, Zebby

    2014-01-01

    Introduction: The aim of this study is to: • Evaluate the current role of the consultant breast radiographer. • Compare current practice with the four key components for consultant practice. • Gauge the support of radiologist colleagues. • Determine the other professional commitments involved with the role. This study could be the precursor for a macro study of all consultant radiographer practice in other specialities. Methodology: Methodology used was a comparative ethnographic study. Questionnaires to the 24 consultant breast radiographers currently in post, and consultant breast radiologists, who work with them, were conducted. Data collection was a qualitative thematic approach. Conclusion: Consultant breast radiographers provide high quality care to patients through excellent clinical practice, leadership and good communication. However, this study shows hospital Trusts emphasis for non medical consultants is for clinical practice first. Some radiologists are still a barrier to progression for consultant breast radiographers, and radiologists have a big influence in recruitment decisions. Consultant breast radiographer posts are well established, their numbers are increasing through recognition of the role and of their abilities and performance. Consultant breast radiographers state that becoming a consultant is the major achievement of their career, proving the Society of Radiographers' vision of the four-tier career structure has been well received by the radiography profession

  1. Importance of radiographic monitoring of endoscopic sphincterotomy

    International Nuclear Information System (INIS)

    Greenberg, H.M.; Goldberg, H.I.; Shapiro, H.A.

    1981-01-01

    The radiographic features of endoscopic sphincterotomies performed in 44 patients were evaluated. Radiographic landmarks aided in proper sphincterotome placement and also disclosed conditions and anatomic variations that made catheter placement difficult. Fluoroscopic and radiographic monitoring not only assisted the performance of endoscopic sphincterotomy, but also confirmed successful results and revealed reasons for failure. Radiographic changes in the biliary tract after sphincterotomy, as well as potential complications of sphincterotomy, are discussed and illustrated

  2. Radiation protection - radiographer's role and responsibilities

    International Nuclear Information System (INIS)

    Popli, P.K.

    2002-01-01

    Ever since discovery of x-rays, radiographers has been the prime user of radiation. With the passage of time, the harmful effects of radiation were detected. Some of radiographers, radiologists and public were affected by radiation, but today with enough knowledge of radiation, the prime responsibility of radiation protection lies with the radiographers only. The radiologist and physicist are also associated with radiation protection to some extent

  3. STUDY OF EFFECTIVE TIME OF UNDILUTED FIXINGSOLUTIONS INLIGHTENING OF THE HIGH DENSITY PERIAPICAL RADIOGRAPHS

    Directory of Open Access Journals (Sweden)

    A ZAMANI NASER

    2003-12-01

    Full Text Available Introduction: Dental radiographs are occationally too dark because of different reasons such as over exposure, high concen-tration of developing solution and over development. Different chemicals are used to lighten these radiographs. In this research the undiluted fixed solution for the first time are tested and efficiency time of this solution in reducing the density of dark radiographs were evaluated. Method: Use of a dry mandible containing some teeth and 98 E speed periapical radiographs were prepared as foolow: A film wasexposed with 0.4 S... as positive control (ideal. 97 films were exposed with 1.8 S (dark and unreadable. Out of 97, one radiograph kept as positive control and remaining films prepared for study. All of radiographs developed and fixed with automatic processor in the same conditio. Out of 96 dark radiograph, 3 was used for pilot study and inserted in the undiluted fixing solution in different time. (2.5, 3 and 3.5 hrs. The result of pilot study showed that aii3 radiographs showed reductionin density and radiographs with her reduction time was closest to positive control for density and diognostic quality and radiograph with 2.5 hrs reduction time and 3.5 hre became darker and lighter as compared to positive control. The remaining 93 high density radiographs were divided into 3 groups, 31 in each group (group 1,2 and 3 first group 2.5 hrs, second 3 hrs and the third group 3.5 hrs were kept in undiluted fixed solution. for this, disposable glasses were used and in each glass a radiograph were inserted. The research time was spring and the temperature was about 2609 (without coolant. Evaluation of radiographs: For evaluation of radiographs 2 methods were used: First method used was: Densitometry: By this method the density of total lightened radiographs, positive control and negative control were determined. Another method was determined diagnostic quality of radiographs visually by radiologists, throng this way: Special

  4. Intra-observer reproducibility and interobserver reliability of the radiographic parameters in the Spinal Deformity Study Group's AIS Radiographic Measurement Manual.

    Science.gov (United States)

    Dang, Natasha Radhika; Moreau, Marc J; Hill, Douglas L; Mahood, James K; Raso, James

    2005-05-01

    Retrospective cross-sectional assessment of the reproducibility and reliability of radiographic parameters. To measure the intra-examiner and interexaminer reproducibility and reliability of salient radiographic features. The management and treatment of adolescent idiopathic scoliosis (AIS) depends on accurate and reproducible radiographic measurements of the deformity. Ten sets of radiographs were randomly selected from a sample of patients with AIS, with initial curves between 20 degrees and 45 degrees. Fourteen measures of the deformity were measured from posteroanterior and lateral radiographs by 2 examiners, and were repeated 5 times at intervals of 3-5 days. Intra-examiner and interexaminer differences were examined. The parameters include measures of curve size, spinal imbalance, sagittal kyphosis and alignment, maximum apical vertebral rotation, T1 tilt, spondylolysis/spondylolisthesis, and skeletal age. Intra-examiner reproducibility was generally excellent for parameters measured from the posteroanterior radiographs but only fair to good for parameters from the lateral radiographs, in which some landmarks were not clearly visible. Of the 13 parameters observed, 7 had excellent interobserver reliability. The measurements from the lateral radiograph were less reproducible and reliable and, thus, may not add value to the assessment of AIS. Taking additional measures encourages a systematic and comprehensive assessment of spinal radiographs.

  5. CT colonography training for radiographers - a formal evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Haycock, A. [Intestinal Imaging Centre and Wolfson Unit for Endoscopy, St Mark' s Hospital, Imperial College London, London (United Kingdom); Burling, D., E-mail: burlingdavid@yahoo.co.u [Intestinal Imaging Centre and Wolfson Unit for Endoscopy, St Mark' s Hospital, Imperial College London, London (United Kingdom); Wylie, P.; Muckian, J.; Ilangovan, R.; Thomas-Gibson, S. [Intestinal Imaging Centre and Wolfson Unit for Endoscopy, St Mark' s Hospital, Imperial College London, London (United Kingdom)

    2010-12-15

    Aims: To evaluate the efficacy of a new intensive 'hands-on' course designed to train small teams of radiographers in computed tomography colonography (CTC) technique and initial interpretation for patient triage. Materials and methods: The course comprised small-group lectures, active participation in the daily CTC service with practical technique and image interpretation training by experienced radiologists and radiographers. Evaluation was by assessment of knowledge using randomized sets of multiple choice questions (MCQ; pre/post-course), practical technique using checklists and expert global scores, and interpretation performance outcomes using randomized pre/post-course test datasets (five validated CTC examinations each). Paired t-tests were used to investigate change in performance for MCQ score and interpretation accuracy. Results: Thirteen courses with 49 participants were evaluated over 2 years. Practical skills were high, with mean (SD) checklist scores of 14/15 (0.85) and global scores of 26/30 (2.3). MCQ scores increased significantly from a mean of 59% pre-course to 69% post-course, p < 0.001. Correct classification of CTC examination improved significantly from a mean of 55% pre-course to 71% post-course, p < 0.001. Cancer and large polyp (>10 mm) detection rates also improved significantly from 49% to 60%, p = 0.002. Conclusion: Structured training in CTC can significantly improve knowledge and interpretation skills of radiographers, while assessing safe procedural performance. Implementation of similar programmes nationally may help reduce performance gaps between centres.

  6. A critical test of bivelocity hydrodynamics for mixtures.

    Science.gov (United States)

    Brenner, Howard

    2010-10-21

    The present paper provides direct noncircumstantial evidence in support of the existence of a diffuse flux of volume j(v) in mixtures. As such, it supersedes an earlier paper [H. Brenner, J. Chem. Phys. 132, 054106 (2010)], which offered only indirect circumstantial evidence in this regard. Given the relationship of the diffuse volume flux to the fluid's volume velocity, this finding adds additional credibility to the theory of bivelocity hydrodynamics for both gaseous and liquid continua, wherein the term bivelocity refers to the independence of the fluid's respective mass and volume velocities. Explicitly, the present work provides a new and unexpected linkage between a pair of diffuse fluxes entering into bivelocity mixture theory, fluxes that were previously regarded as constitutively independent, except possibly for their coupling arising as a consequence of Onsager reciprocity. In particular, for the case of a binary mixture undergoing an isobaric, isothermal, external force-free, molecular diffusion process we establish by purely macroscopic arguments-while subsequently confirming by purely molecular arguments-the validity of the ansatz j(v)=(v(1)-v(2))j(1) relating the diffuse volume flux j(v) to the diffuse mass fluxes j(1)(=-j(2)) of the two species and, jointly, their partial specific volumes v(1),v(2). Confirmation of that relation is based upon the use of linear irreversible thermodynamic principles to embed this ansatz in a broader context, and to subsequently establish the accord thereof with Shchavaliev's solution of the multicomponent Boltzmann equation for dilute gases [M. Sh. Shchavaliev, Fluid Dyn. 9, 96 (1974)]. Moreover, because the terms v(1), v(2), and j(1) appearing on the right-hand side of the ansatz are all conventional continuum fluid-mechanical terms (with j(1) given, for example, by Fick's law for thermodynamically ideal solutions), parity requires that j(v) appearing on the left-hand side of that relation also be a continuum term

  7. Diagnostic value of the chest radiograph in asymptomatic neonates with a cardiac murmur

    International Nuclear Information System (INIS)

    Oeppen, R.S.; Fairhurst, J.J.; Argent, J.D.

    2002-01-01

    AIM: To establish the diagnostic accuracy and diagnostic usefulness of the chest radiograph in asymptomatic neonates with cardiac murmurs. PATIENTS AND METHODS: The chest radiographs of 68 asymptomatic neonates with cardiac murmurs were analysed retrospectively. The radiographs were anonymized and then evaluated for the presence or absence of cardiac disease by six radiologists, three who regularly interpret neonatal chest radiographs and three who do so infrequently. The eventual diagnosis for each neonate and the impact of the chest radiograph and original report on patient management were established by review of the clinical case notes. RESULTS: The results for each observer were expressed in 2 x 2 contingency tables and statistical analysis was performed using Fisher's exact test. The radiologists who were experienced in reporting neonatal chest radiographs achieved statistically significant results (P = 0.003, P = 0.002 andP = 0.007) compared with those who were less experienced (P = 0.13, P = 0.16 andP = 0.09). Review of the case notes established that the chest radiograph and original report did not influence clinical management in any of the 68 cases studied. CONCLUSIONS: Radiologists who frequently report neonatal chest radiographs achieve high accuracy in differentiating cardiac from non-cardiac disease. However, inaccuracies are unavoidable as radiological evidence of cardiac disease is often not present. A false-positive result could cause undue anxiety while a false-negative report could result in the omission of further investigations. Furthermore, a chest radiograph is unlikely to provide the definitive diagnosis. Chest radiographs did not appear to influence patient management in this study and cannot be recommended in the initial evaluation of the asymptomatic neonate with a heart murmur. Oeppen, R.S. et al. (2002)

  8. 3-D CFD simulations of hydrodynamics in the Sulejow dam reservoir

    Directory of Open Access Journals (Sweden)

    Ziemińska-Stolarska Aleksandra

    2015-12-01

    Full Text Available This paper reports the processes by which a single-phase 3-D CFD model of hydrodynamics in a 17-km-long dam reservoir was developed, verified and tested. A simplified VOF model of flow was elaborated to determine the effect of wind on hydrodynamics in the lake. A hexahedral mesh with over 17 million elements and a k-ω SST turbulence model were defined for single-phase simulations in steady-state conditions. The model was verified on the basis of the extensive flow measurements (StreamPro ADCP, USA. Excellent agreement (average error of less than 10% between computed and measured velocity profiles was found. The simulation results proved a strong effect of wind on hydrodynamics in the lake, especially on the development of the water circulation pattern in the lacustrine zone.

  9. MINAC, portable high energy radiographic inspection system

    International Nuclear Information System (INIS)

    Lapides, M.E.; Schonberg, R.

    1985-01-01

    MINAC, a portable, high energy radiographic source (1) was recognized as a desired inspection device for nuclear generation plants during EPRI-sponsored studies of the late 1970s and rapidly transitioned from proof-of-principle (1978-1980) to field-proven hardware (1981-present date). The equipment has completed its second generation of configuration development (SHRINKAC), that has recently been used in the field for detection of pipe cracks. Important auxiliaries for image data processing and real-time, thick section radiography have been demonstrated in both laboratory and field situations. Finally, a 6 MeV accelerator alternate is in bench test. These significant developments have, and are expected to continue to upgrade the utility of radiographic inspection in power plant practice. This paper describes the development and experience with this modular system during the last three years

  10. Hydrodynamics of electrons in graphene

    Science.gov (United States)

    Lucas, Andrew; Chung Fong, Kin

    2018-02-01

    Generic interacting many-body quantum systems are believed to behave as classical fluids on long time and length scales. Due to rapid progress in growing exceptionally pure crystals, we are now able to experimentally observe this collective motion of electrons in solid-state systems, including graphene. We present a review of recent progress in understanding the hydrodynamic limit of electronic motion in graphene, written for physicists from diverse communities. We begin by discussing the ‘phase diagram’ of graphene, and the inevitable presence of impurities and phonons in experimental systems. We derive hydrodynamics, both from a phenomenological perspective and using kinetic theory. We then describe how hydrodynamic electron flow is visible in electronic transport measurements. Although we focus on graphene in this review, the broader framework naturally generalizes to other materials. We assume only basic knowledge of condensed matter physics, and no prior knowledge of hydrodynamics.

  11. Evaluation of underexposed conventional radiographs after digitization. Auswertung fehlbelichteter konventioneller Roentgenaufnahmen nach Digitalisierung

    Energy Technology Data Exchange (ETDEWEB)

    Wenz, W. (Freiburg Univ. (Germany). Abt. Roentgendiagnostik); Buitrago-Tellez, C. (Freiburg Univ. (Germany). Abt. Roentgendiagnostik); Moenig, H. (Freiburg Univ. (Germany). Inst. fuer Biophysik und Strahlenbiologie); Niemeier, R. (Digital Diagnostik Deutschland GmbH, Freiburg im Breisgau (Germany))

    1993-02-01

    Inadequate exposure of analogue radiographs is reported in the literature to occur in 5-25% of cases. Therefore, the present study was performed to test whether selective image processing after digitization could reveal diagnostic details on underexposed radiographs. In addition, the minimal exposure values required for diagnostic purposes after adequate image processing were studied. Phantom studies, organ preparations and measurements of physical parameters with decreasing exposure values were performed. The detection of anatomic and pathologic (nondisplaced fracture lines, microcalcification and renal stones) structures were evaluated by 12 readers. Radiographs with exposure values 20-40% lower than 'ideal' values can provide adequate diagnostic images after digital processing. The diagnostic information is significantly impaired with values under 50% of the correct exposure values. In conclusion, this method is adequate to save underexposed radiographs for diagnostic purposes and to avoid repeated examinations. (orig.)

  12. Biometric Analysis - A Reliable Indicator for Diagnosing Taurodontism using Panoramic Radiographs.

    Science.gov (United States)

    Hegde, Veda; Anegundi, Rajesh Trayambhak; Pravinchandra, K R

    2013-08-01

    Taurodontism is a clinical entity with a morpho-anatomical change in the shape of the tooth, which was thought to be absent in modern man. Taurodontism is mostly observed as an isolated trait or a component of a syndrome. Various techniques have been devised to diagnose taurodontism. The aim of this study was to analyze whether a biometric analysis was useful in diagnosing taurodontism, in radiographs which appeared to be normal on cursory observations. This study was carried out in our institution by using radiographs which were taken for routine procedures. In this retrospective study, panoramic radiographs were obtained from dental records of children who were aged between 9-14 years, who did not have any abnormality on cursory observations. Biometric analyses were carried out on permanent mandibular first molar(s) by using a novel biometric method. The values were tabulated and analysed. Fischer exact probability test, Chi square test and Chi-square test with Yates correction were used for statistical analysis of the data. Cursory observation did not yield us any case of taurodontism. In contrast, the biometric analysis yielded us a statistically significant number of cases of taurodontism. However, there was no statistically significant difference in the number of cases with taurodontism, which was obtained between the genders and the age group which was considered. Thus, taurodontism was diagnosed on a biometric analysis, which was otherwise missed on a cursory observation. It is therefore necessary from the clinical point of view, to diagnose even the mildest form of taurodontism by using metric analysis rather than just relying on a visual radiographic assessment, as its occurrence has many clinical implications and a diagnostic importance.

  13. Radiopacity evaluation of Portland and MTA-based cements by digital radiographic system.

    Science.gov (United States)

    Borges, Alvaro Henrique; Pedro, Fabio Luiz Miranda; Semanoff-Segundo, Alex; Miranda, Carlos Eduardo Saraiva; Pécora, Jesus Djalma; Cruz Filho, Antônio Miranda

    2011-01-01

    The aim of the present study was to evaluate the radiopacity of Portland and MTA-based cements using the Digora TM digital radiographic system. The performed tests followed specification number 57 from the American National Standard Institute/American Dental Association (2000) for endodontic sealing materials. The materials were placed in 5 acrylic plates, especially designed for this experiment, along with a graduated aluminum stepwedge varying from 1 to 10 mm in thickness. The set was radiographed at a 30 cm focus-object distance and with 0.2 s exposure time. After the radiographs were taken, the optical laser readings of radiographs were performed by Digora TM system. Five radiographic density readings were performed for each studied material and for each step of the aluminum scale. White ProRoot MTA (155.99±8.04), gray ProRoot MTA (155.96±16.30) and MTA BIO (143.13±16.94) presented higher radiopacity values (pPortland (119.76±22.34), gray Portland (109.71±4.90) and white structural Portland (99.59±12.88) presented lower radiopacity values (pcements were the only materials presenting radiopacity within the ANSI/ADA specifications.

  14. Black brane entropy and hydrodynamics

    NARCIS (Netherlands)

    Booth, I.; Heller, M.P.; Spaliński, M.

    2010-01-01

    A generalization of entropy to near-equilibrium phenomena is provided by the notion of a hydrodynamic entropy current. Recent advances in holography have lead to the formulation of fluid-gravity duality, a remarkable connection between the hydrodynamics of certain strongly coupled media and dynamics

  15. Black brane entropy and hydrodynamics

    NARCIS (Netherlands)

    Booth, I.; Heller, M.P.; Spaliński, M.

    2011-01-01

    A generalization of entropy to near-equilibrium phenomena is provided by the notion of a hydrodynamic entropy current. Recent advances in holography have lead to the formulation of fluid-gravity duality, a remarkable connection between the hydrodynamics of certain strongly coupled media and dynamics

  16. Radiographic, high detail radiographic, microangiographic and histological findings of the distal portion of the tarsus in weanling young and adult horses

    International Nuclear Information System (INIS)

    Laverty, S.; Stover, S.M.; Bélanger, D.; O'Brien, T.R.; Pool, R.R.; Pascoe, J.R.; Taylor, K.; Harrington, T.

    1991-01-01

    Clinical radiographic (LM and D35L-P1MO reviews), high detail radiographic, microangiographic and histological findings of distal portion of the tarsus of 16 horses (five weanling, four young and six adult), without known clinical histories, were evaluated to determine the sensitivity of clinical radiographs for the detection of abnormalities in the distal tarsus and the prevalence of abnormalities in this population. Clinical radiographic and high detail radiographic abnormalities were observed in at least 30 per cent of the tarsi examined. Statistical agreement between observations from clinical radiographs and corresponding post mortem high detail radiographs was not good for subchondral bone plate irregularities and joint margin changes. Three patterns of sclerosis of the medullary spongiosa were visualized on high detail radiographs; thickening of the subchondral bone plate was seen commonly in the weaning group,, whereas arching and bridging patterns were more prevalent in the young and adult groups. Bone production on the dorsal cortex of the central and third tarsal bones did not increase with age. Abnormalities in vascular perfusion and articular cartilage histology were observed in association with subchondral bone plate irregularities and focal regions of osteopenia observed on high detail radiographs

  17. Simulated radiographic bone and joint modeling from 3D ankle MRI: feasibility and comparison with radiographs and 2D MRI

    Energy Technology Data Exchange (ETDEWEB)

    Nordeck, Shaun M. [University of Texas Southwestern Medical College, Dallas, TX (United States); University of Texas Southwestern Medical Center, Musculoskeletal Radiology, Dallas, TX (United States); Koerper, Conrad E.; Adler, Aaron [University of Texas Southwestern Medical College, Dallas, TX (United States); Malhotra, Vidur; Xi, Yin [University of Texas Southwestern Medical Center, Musculoskeletal Radiology, Dallas, TX (United States); Liu, George T. [University of Texas Southwestern Medical Center, Orthopaedic Surgery, Dallas, TX (United States); Chhabra, Avneesh [University of Texas Southwestern Medical Center, Musculoskeletal Radiology, Dallas, TX (United States); University of Texas Southwestern Medical Center, Orthopaedic Surgery, Dallas, TX (United States)

    2017-05-15

    The purpose of this work is to simulate radiographs from isotropic 3D MRI data, compare relationship of angle and joint space measurements on simulated radiographs with corresponding 2D MRIs and real radiographs (XR), and compare measurement times among the three modalities. Twenty-four consecutive ankles were included, eight males and 16 females, with a mean age of 46 years. Segmented joint models simulating radiographs were created from 3D MRI data sets. Three readers independently performed blinded angle and joint space measurements on the models, corresponding 2D MRIs, and XRs at two time points. Linear mixed models and the intraclass correlation coefficient (ICC) was ascertained, with p values less than 0.05 considered significant. Simulated radiograph models were successfully created in all cases. Good agreement (ICC > 0.65) was noted among all readers across all modalities and among most measurements. Absolute measurement values differed between modalities. Measurement time was significantly greater (p < 0.05) on 2D versus simulated radiographs for most measurements and on XR versus simulated radiographs (p < 0.05) for nearly half the measurements. Simulated radiographs can be successfully generated from 3D MRI data; however, measurements differ. Good inter-reader and moderate-to-good intra-reader reliability was observed and measurements obtained on simulated radiograph models took significantly less time compared to measurements with 2D and generally less time than XR. (orig.)

  18. Radiographic Evidence of Hip Microinstability in Elite Ballet.

    Science.gov (United States)

    Mitchell, Ronald J; Gerrie, Brayden J; McCulloch, Patrick C; Murphy, Andrew J; Varner, Kevin E; Lintner, David M; Harris, Joshua D

    2016-06-01

    To determine prevalence, magnitude, and predisposing radiographic features of hip subluxation in elite ballet dancers. A cross-sectional investigation of professional male and female ballet dancers was performed using 5 plain radiographs. A "splits" anteroposterior (AP) radiograph was performed with legs abducted parallel to the trunk in the coronal plane (splits position; grand écart facial). Hip center position (HCP) was measured on standing AP pelvis and AP pelvis splits views and the difference calculated (subluxation distance) to determine prevalence and magnitude of femoral head subluxation. Student t test compared HCP on AP pelvis and splits radiographs. Pearson correlations were used to correlate splits HCP with radiographic measures of femoroacetabular impingement and dysplasia. Analyzing 47 dancers (21 men, 26 women; 23.8 ± 5.4 years), mean HCP on standing AP pelvis was 9.39 ± 3.33 mm versus 10.8 ± 2.92 mm on splits radiograph, with mean subluxation distance of 1.41 mm (P = .035). Forty-two dancers' femoral heads translated laterally with splits positioning, and 17 dancers (36%) exhibited a "vacuum sign" (bilateral in 71% of subjects with at least 1 hip vacuum sign). There was strong positive correlation (r = 0.461, P = .001) with splits HCP and alpha angle (Dunn 45°), and moderate negative correlation (r = -0.332, P = .022) with subluxation distance and neck-shaft angle. In men, splits HCP increased as lateral center edge angle (CEA) decreased (r = -0.437, P = .047), as anterior CEA decreased (r = -0.482, P = .027), as Tönnis angle increased (r = 0.656, P = .001), and as femoral head extrusion index increased (r = 0.511, P = .018). In women, there was moderate negative correlation (r = -0.389, P = .049) with subluxation distance and neck-shaft angle. Hip subluxation occurs during splits in most professional ballet dancers, with a significantly greater magnitude of subluxation in women than men. Subluxation magnitude

  19. Predicting lower third molar eruption on panoramic radiographs after cephalometric comparison of profile and panoramic radiographs

    DEFF Research Database (Denmark)

    Begtrup, Anders; Grønastøð, Halldis Á; Christensen, Ib Jarle

    2012-01-01

    and to find a simple and reliable method for predicting the eruption of the mandibular third molar by measurements on panoramic radiographs. The material consisted of profile and panoramic radiographs, taken before orthodontic treatment, of 30 males and 23 females (median age 22, range 18-48 years......Previous studies have suggested methods for predicting third molar tooth eruption radiographically. Still, this prediction is associated with uncertainty. The aim of the present study was to elucidate the association between cephalometric measurements on profile and panoramic radiographs...... the length from the ramus to the incisors (olr-id) showed a statistically significant correlation. By combining this length with the mesiodistal width of the lower second molar, the prediction of eruption of the lower third molar was strengthened. A new formula for calculating the probability of eruption...

  20. Ergonomic strategies to improve radiographers' posture during mammography activities.

    Science.gov (United States)

    Cernean, Nicolai; Serranheira, Florentino; Gonçalves, Pedro; Sá Dos Reis, Cláudia

    2017-08-01

    To identify alternatives for radiographers' postures while performing mammography that can contribute to reduce the risk of work-related musculoskeletal disorders (WRMSDs). Radiographers' postures to positioning craniocaudal (CC) and mediolateral oblique (MLO) views were simulated without any intervention for three scenarios: radiographer/patient with similar statures, radiographer smaller than patient and radiographer taller than patient. Actions were taken to modify the postures: seated radiographer; patient on a step; seated patient; radiographer on a step. All the postures were analysed using kinovea 0.8.15 software and the angles were measured twice and classified according to European standard EN1005-4: 2005. The non-acceptable angles were measured mainly during MLO positioning when radiographer was taller than the patient: 139° and 120° for arm-flexion and abduction, 72° for trunk and -24° for head/neck-flexion. The introduction of alternative postures (radiographer seated), allowed improvements in posture (60° and 99° for arm flexion and abduction, 14° for trunk and 0° for head/neck flexion), being classified as acceptable. The alternative postures simulated have the potential to reduce the risk of developing WRMSDs when radiographers and patients have different statures. • Radiographers' postures in mammography can contribute to work-related musculoskeletal disorders • Non-acceptable posture was identified for MLO breast positioning (radiographer taller than patient) • Adapting posture to patient biotype reduces the WRMSD risk for radiographers.

  1. Prenatal radiographic diagnosis of alpha-fetoprotein positive malformations in early pregnancy

    International Nuclear Information System (INIS)

    Probst, F.P.; Sigurd, J.

    1980-01-01

    Early diagnosis of two malformed fetuses with positive alpha-fetoprotein test of the amniotic fluid with the aid of amniography is reported. Radiographic, diagnostic and prognostic aspects are discussed. (Auth.)

  2. Topics in fluctuating nonlinear hydrodynamics

    International Nuclear Information System (INIS)

    Milner, S.T.

    1986-01-01

    Models of fluctuating nonlinear hydrodynamics have enjoyed much success in explaining the effect of long-wavelength fluctuations in diverse hydrodynamic systems. This thesis explores two such problems; in both, the body of hydrodynamic assumptions powerfully constrains the predictions of a well-posed theory. The effects of layer fluctuations in smectic-A liquid crystals are first examined. The static theory (introduced by Grinstein and Pelcovits) is reviewed. Ward identities, resulting from the arbitrariness of the layering direction, are derived and exploited. The static results motivate an examination of dynamic fluctuation effects. A new sound-damping experiment is proposed that would probe singular dependence of viscosities on applied stress. A theory of Procaccia and Gitterman that reaction rates of chemically reacting binary mixtures are drastically reduced near their thermodynamic critical points is analyzed. Hydrodynamic arguments and Van Hove theory are applied, concluding that the PG idea is drastically slowed, and spatially varying composition fluctuations are at best slowed down over a narrow range of wavenumbers

  3. High Variability of Observed Weight Bearing During Standing Foot and Ankle Radiographs.

    Science.gov (United States)

    Miller, Christopher P; Ghorbanhoseini, Mohammad; Ehrlichman, Lauren K; Walley, Kempland C; Ghaheri, Azadeh; Kwon, John Y

    2017-06-01

    Weight-bearing radiographs are a critical component of evaluating foot and ankle pathology. An underlying assumption is that patients are placing 50% of their body weight on the affected foot during image acquisition. The accuracy of weight bearing during radiographs is unknown and, presumably, variable, which may result in uncertain ability of the resultant radiographs to appropriately portray the pathology of interest. Fifty subjects were tested. The percentage body weight through the foot of interest was measured at the moment of radiographic image acquisition. The subject was then instructed to bear "half [their] weight" prior to the next radiograph. The percentage body weight was calculated and compared to ideal 50% weight bearing. The mean percentage body weight in trial 1 and 2 was 45.7% ± 3.2% ( P = .012 compared to the 50% mark) and 49.2% ± 2.4%, respectively ( P = .428 compared to 50%). The mean absolute difference in percentage weight bearing compared to 50% in trials 1 and 2 was 9.3% ± 2.3% and 5.8% ± 1.8%, respectively ( P = .005). For trial 1, 18/50 subjects were within the "ideal" (45%-55%) range for weight bearing compared to 32/50 on trial 2 ( P = .005). In trial 1, 24/50 subjects had "appropriate" (>45%) weight bearing compared to 39/50 on trial 2 ( P = .002). There was substantial variability in the weight applied during radiograph acquisition. This study raises questions regarding the assumptions, reliability, and interpretation when evaluating weight-bearing radiographs. Level III, comparative study.

  4. Chest radiograph interpretation by medical students

    International Nuclear Information System (INIS)

    Jeffrey, D.R.; Goddard, P.R.; Callaway, M.P.; Greenwood, R.

    2003-01-01

    AIM: To assess the ability of final year medical students to interpret conventional chest radiographs. MATERIALS AND METHODS: Ten conventional chest radiographs were selected from a teaching hospital radiology department library that were good radiological examples of common conditions. All were conditions that a medical student should be expected to recognize by the end of their training. One normal radiograph was included. The radiographs were shown to 52 final year medical students who were asked to describe their findings. RESULTS: The median score achieved was 12.5 out of 20 (range 6-18). There was no difference between the median scores of male and female students (12.5 and 12.3, respectively, p=0.82) but male students were more likely to be certain of their answers than female students (median certainty scores 23.0 and 14.0, respectively). The overall degree of certainty was low. On no radiograph were more than 25% of students definite about their answer. Students had received little formal radiology teaching (2-42 h, median 21) and few expressed an interest in radiology as a career. Only two (3.8%) students thought they were good at interpreting chest radiographs, 17 (32.7%) thought they were bad or awful. CONCLUSION: Medical students reaching the end of their training do not perform well at interpreting simple chest radiographs. They lack confidence and have received little formal radiological tuition. Perhaps as a result, few are interested in radiology as a career, which is a matter for concern in view of the current shortage of radiologists in the UK

  5. Radiographic markers - A reservoir for bacteria?

    International Nuclear Information System (INIS)

    Tugwell, Jenna; Maddison, Adele

    2011-01-01

    Introduction: Amongst the most frequently handled objects in the radiology department are radiographic markers. They are personal accessories used with every patient, and are kept in the radiographers pockets when not utilised. Upon enquiry it was discovered that many radiographers disregarded the potential of these accessories to become a vector for cross-contamination thus never or rarely clean them. The aims of this study were therefore to identify if radiographic markers are a reservoir for bacteria and to establish an effective cleaning method for decontaminating them. Methodology: 25 radiographers/student radiographers were selected for this study. Swabbing of their markers prior and post cleaning took place. The microbiology laboratory subsequently analyzed the results by quantifying and identifying the bacteria present. The participants also completed a closed questionnaire regarding their markers (e.g. frequency of cleaning and type of marker) to help specify the results gained from the swabbing procedure. Results: From the sample swabbed, 92% were contaminated with various organisms including Staphylococcus and Bacillus species, the amount of bacteria present ranged from 0 to >50 CFU. There were no significant differences between disinfectant wipes and alcohol gel in decontaminating the markers. Both successfully reduced their bacterial load, with 80% of the markers post cleaning having 0 CFU. Conclusion: The results indicated that radiographic markers can become highly contaminated with various organisms thus serve as a reservoir for bacteria. In addition, the markers need to be cleaned on a regular basis, with either disinfectant wipes or alcohol gel to reduce their bacterial load.

  6. High resolution CT in children with cystic fibrosis: correlation with pulmonary functions and radiographic scores

    Energy Technology Data Exchange (ETDEWEB)

    Demirkazik, Figen Basaran E-mail: demirkaz@dialup.ankara.edu.tr; Ariyuerek, O. Macit; Oezcelik, Ugur; Goecmen, Ayhan; Hassanabad, Hossein K.; Kiper, Nural

    2001-01-01

    Objective: To compare the high resolution CT (HRCT) scores of the Bhalla system with pulmonary function tests and radiographic and clinical points of the Shwachman-Kulczycki clinical scoring system. Methods: HRCT of the chest was obtained in 40 children to assess the role of HRCT in evaluating bronchopulmonary pathology in children with cystic fibrosis (CF). The HRCT severity scores of the Bhalla system were compared with chest radiographic and clinical points of the Shwachman-Kulczycki scoring system and pulmonary function tests. Only 14 of the patients older than 6 years cooperated with spirometry. Results: HRCT scores correlated well with radiographic points (r=0.80, P<0.0001) and clinical points (r=0.67, P<0.0001) of the Shwachman-Kulczycki system, FVC (r=0.71 P=0.004) and FEV{sub 1} (r=0.66, P=0.01). Although radiographic points correlated significantly with FVC (r=0.61, P=0.02) and FEV{sub 1} (r=0.56, P=0.04), HRCT provides a more precise scoring than the chest X-ray. Conclusion: The HRCT scoring system may provide a sensitive method of monitoring pulmonary disease status and may replace the radiographic scoring in the Shwachman-Kulczycki system. It may be helpful especially in follow-up of small children too young to cooperate with spirometry.

  7. Immunologic basis for adverse reactions to radiographic contrast media

    Energy Technology Data Exchange (ETDEWEB)

    Stejskal, V; Nilsson, R; Grepe, A [Astra Pharmaceuticals AB, Soedertaelje (Sweden). Lab. of Safety Assessment Stockholm Univ. (Sweden). Dept. of Genetic and Cellular Toxicology Stockholm Univ. (Sweden). Wallenberglaboratoriet Danderyds Sjukhus, Danderyd (Sweden). Radiologic Clinic

    1990-11-01

    The lymphocyte transformation test (LTT) was used to elucidate whether certain side effects induced by radiographic contrast media have an immunologic etiology. Groups studied were: 8 patients who had previously experienced adverse reactions in association with urography, 6 patients who underwent urography without notable side reactions, 17 occupationally exposed nurses, and 9 unexposed controls. The lymphocytes from 2 hypersensitive patients and from 11 nurses exhibited a positive proliferative response to amidotrizoate. Five nurses who had shown a positive response, had a previous history of hypersensitivity reactions when handling contrast media, whereas the remaining 6 were free of symptoms. Amidotrizoatespecific memory cells were absent in patients who underwent urography without signs of hypersensitivity and in 7/9 of unexposed control subjects. Lymphocytes from patients sensitive to amidotrizoate cross-reacted to structurally related ionic contrast media while nonionic contrast agents did not induce proliferation of the lymphocytes. Thus, ionic radiographic contrast agents have antigenic properties in man. Irradiated mixtures of radiographic contrast media and serum proteins were, in general, not effective in inducing an LTT response. (orig.).

  8. Immunologic basis for adverse reactions to radiographic contrast media

    International Nuclear Information System (INIS)

    Stejskal, V.; Nilsson, R.; Grepe, A.; Stockholm Univ.; Stockholm Univ.; Danderyds Sjukhus, Danderyd

    1990-01-01

    The lymphocyte transformation test (LTT) was used to elucidate whether certain side effects induced by radiographic contrast media have an immunologic etiology. Groups studied were: 8 patients who had previously experienced adverse reactions in association with urography, 6 patients who underwent urography without notable side reactions, 17 occupationally exposed nurses, and 9 unexposed controls. The lymphocytes from 2 hypersensitive patients and from 11 nurses exhibited a positive proliferative response to amidotrizoate. Five nurses who had shown a positive response, had a previous history of hypersensitivity reactions when handling contrast media, whereas the remaining 6 were free of symptoms. Amidotrizoatespecific memory cells were absent in patients who underwent urography without signs of hypersensitivity and in 7/9 of unexposed control subjects. Lymphocytes from patients sensitive to amidotrizoate cross-reacted to structurally related ionic contrast media while nonionic contrast agents did not induce proliferation of the lymphocytes. Thus, ionic radiographic contrast agents have antigenic properties in man. Irradiated mixtures of radiographic contrast media and serum proteins were, in general, not effective in inducing an LTT response. (orig.)

  9. Reference Neutron Radiographs of Nuclear Reactor Fuel

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    Reference neutron radiographs of nuclear reactor fuel were produced by the Euraton Neutron Radiography Working Group and published in 1984 by the Reidel Publishing Company. In this collection a classification is given of the various neutron radiographic findings, that can occur in different parts...... of pelletized, annular and vibro-conpacted nuclear fuel pins. Those parts of the pins are shown where changes of appearance differ from those for the parts as fabricated. Also radiographs of those as fabricated parts are included. The collection contains 158 neutron radiographs, reproduced on photographic paper...

  10. Brazilian young dental practitioners' use and acceptance of digital radiographic examinations

    International Nuclear Information System (INIS)

    Rovaris, Karla; De Faria Vasconcelos, Karla; Do Nascimento, Eduarda Helena Leandro; Oliveira, Matheus Lima; Freitas, Deborah Queiroz; Haiter-Neto, Francisco

    2016-01-01

    The aim of this study was to investigate the use and acceptance of digital radiographic examinations by Brazilian dental practitioners in daily practice and to evaluate the advances that have occurred over the past 5 years. Dental practitioners enrolled in extension courses at the Piracicaba Dental School, University of Campinas, Brazil, responded to a self-administered questionnaire in the years 2011 and 2015. They were asked about sociodemographic factors and their knowledge and use of digital radiographic examinations. Descriptive analysis was performed, as well as the chi-square and Fisher exact tests, with a significance level of 5% (α=0.05). A total of 181 participants responded to the questionnaire in the years 2011 and 2015. Most of the respondents worked in private practice, had graduated within the last 5 years, and were between 20 and 30 years old. In 2011, 55.6% of respondents reported having ever used digital radiographic examinations, while in 2015 this number increased significantly to 85.4% (p<.0001), out of which 71.4% preferred it to conventional images. Moreover, 21.4% of respondents reported having used digital radiographic examinations for more than 3 years. A significant increase in use of intraoral digital radiography (p=0.0316) was observed in 2015. In both years, image quality and high cost were indicated, respectively, as the main advantage and disadvantage of digital radiographic examinations. This study showed that digital radiology has become more common in Brazil over the past 5 years. Most of the Brazilian dental practitioners evaluated in 2015 used digital radiographic examinations

  11. Brazilian young dental practitioners' use and acceptance of digital radiographic examinations.

    Science.gov (United States)

    Rovaris, Karla; de Faria Vasconcelos, Karla; do Nascimento, Eduarda Helena Leandro; Oliveira, Matheus Lima; Freitas, Deborah Queiroz; Haiter-Neto, Francisco

    2016-12-01

    The aim of this study was to investigate the use and acceptance of digital radiographic examinations by Brazilian dental practitioners in daily practice and to evaluate the advances that have occurred over the past 5 years. Dental practitioners enrolled in extension courses at the Piracicaba Dental School, University of Campinas, Brazil, responded to a self-administered questionnaire in the years 2011 and 2015. They were asked about sociodemographic factors and their knowledge and use of digital radiographic examinations. Descriptive analysis was performed, as well as the chi-square and Fisher exact tests, with a significance level of 5% (α=0.05). A total of 181 participants responded to the questionnaire in the years 2011 and 2015. Most of the respondents worked in private practice, had graduated within the last 5 years, and were between 20 and 30 years old. In 2011, 55.6% of respondents reported having ever used digital radiographic examinations, while in 2015 this number increased significantly to 85.4% (p<.0001), out of which 71.4% preferred it to conventional images. Moreover, 21.4% of respondents reported having used digital radiographic examinations for more than 3 years. A significant increase in use of intraoral digital radiography (p=0.0316) was observed in 2015. In both years, image quality and high cost were indicated, respectively, as the main advantage and disadvantage of digital radiographic examinations. This study showed that digital radiology has become more common in Brazil over the past 5 years. Most of the Brazilian dental practitioners evaluated in 2015 used digital radiographic examinations.

  12. Relativistic hydrodynamics in the presence of puncture black holes

    International Nuclear Information System (INIS)

    Faber, Joshua A.; Etienne, Zachariah B.; Shapiro, Stuart L.; Taniguchi, Keisuke; Baumgarte, Thomas W.

    2007-01-01

    Many of the recent numerical simulations of binary black holes in vacuum adopt the moving puncture approach. This successful approach avoids the need to impose numerical excision of the black hole interior and is easy to implement. Here we wish to explore how well the same approach can be applied to moving black hole punctures in the presence of relativistic hydrodynamic matter. First, we evolve single black hole punctures in vacuum to calibrate our Baumgarte-Shapiro-Shibata-Nakamura implementation and to confirm that the numerical solution for the exterior spacetime is invariant to any junk (i.e., constraint-violating) initial data employed in the black hole interior. Then we focus on relativistic Bondi accretion onto a moving puncture Schwarzschild black hole as a numerical test bed for our high-resolution shock-capturing relativistic hydrodynamics scheme. We find that the hydrodynamical equations can be evolved successfully in the interior without imposing numerical excision. These results help motivate the adoption of the moving puncture approach to treat the binary black hole-neutron star problem using conformal thin-sandwich initial data

  13. PACS influence the radiographer's work

    International Nuclear Information System (INIS)

    Fridell, Kent; Aspelin, Peter; Edgren, Lars; Lindskoeld, Lars; Lundberg, Nina

    2009-01-01

    Radiological departments are changing rapidly due to the implementation of digital images and PACS (Picture Archiving and Communication Systems). The introduction of new technology seems to dissolve boundaries between the professions in the work environment where the technology is introduced. This process tends to change the organization and its routines. The aim of this qualitative study is to explore changes in radiographers' work with regard to skills, work practice and technology. The study used open-ended interviews to explore the radiographers' perceptions of such changes, and to identify problems and solutions pertaining to work practice. Inspiration is taken from grounded theory to explain the changes in work that were found. Respondents were selected from a total of 133 potential participants as a theoretical or purposive sample. The changing trends within the professional role indicated that radiographers, as image producers, shifted their focus from the ability to set the optimal exposure parameters in order to obtain the optimal image for diagnosis to become expert in exposure parameters, projection techniques and diagnostic practice, having multifaceted skills, as being the jack of all trades. When implementing PACS there was an obvious change in image production. At the start there were visions of new routines, and therefore the radiographers became early adopters to the new technology; in practice the organization was stacked in old routines, as the routines were inflexible and PACS work was pushed into old work routines. Although inflexible, this does not mean that they cannot change, and obviously in 2006 new routines had been implemented making it possible for the radiographers in finding new ways for collaborating with colleagues. The new technology immediately created a vision of improved service to the clinicians. In order to optimize the service the radiographers developed an insight into the need for a more comprehensive change in work using

  14. Radiographic enhancement and analysis system

    International Nuclear Information System (INIS)

    Schlosser, M.S.

    1981-01-01

    Radiographic image enhancement and analysis techniques are discussed as they apply to nondestructive inspection. A system is described which has been developed to enhance and quantitatively evaluate radiographic images using digital computer techniques. Some examples of typical applications are also presented as an introduction to this new inspection technique. (author)

  15. Agreement between radiographic and photographic trabecular patterns

    Energy Technology Data Exchange (ETDEWEB)

    Korstjens, C.M.; Geraets, W.G.M.; Stelt, P.F. van der [Dept. of Oral Radiology, Academic Centre for Dentistry, Amsterdam (Netherlands); Spruijt, R.J. [Div. of Psychosocial Research and Epidemiology, Netherlands Cancer Inst., Amsterdam (Netherlands); Mosekilde, L. [Dept. of Cell Biology, Univ. of Aarhus (Denmark)

    1998-11-01

    Purpose: It has been hypothesized that photographs can facilitate the interpretation of the radiographic characteristics of trabecular bone. The reliability of these photographic and radiographic approaches has been determined, as have various agreements between the two approaches and their correlations with biomechanical characteristics. Material and Methods: Fourteen vertebral bodies were obtained at autopsy from 6 women and 8 men aged 22-76 years. Photographs (n=28) and radiographs (n=28) were taken of midsagittal slices from the third lumbar vertebra. The radiographs and photographs were digitized and the geometric properties of the trabecular architecture were then determined with a digital images analysis technique. Information on the compressive strength and ash density of the vertebral body was also available. Results: The geometric properties of both radiographs and photographs could be measured with a high degree of reliability (Cronbach`s {alpha}>0.85). Agreement between the radiographic and photographic approaches was mediocre as only the radiographic measurements showed insignificant correlations (p<0.05) with the biomechanical characteristics. We suggest that optical phenomena may result in the significant correlations between the photographs and the biomechanical characteristics. Conclusion: For digital image processing, radiography offers a superior description of the architecture of trabecular bone to that offered by photography. (orig.)

  16. Agreement between radiographic and photographic trabecular patterns

    International Nuclear Information System (INIS)

    Korstjens, C.M.; Geraets, W.G.M.; Stelt, P.F. van der; Spruijt, R.J.; Mosekilde, L.

    1998-01-01

    Purpose: It has been hypothesized that photographs can facilitate the interpretation of the radiographic characteristics of trabecular bone. The reliability of these photographic and radiographic approaches has been determined, as have various agreements between the two approaches and their correlations with biomechanical characteristics. Material and Methods: Fourteen vertebral bodies were obtained at autopsy from 6 women and 8 men aged 22-76 years. Photographs (n=28) and radiographs (n=28) were taken of midsagittal slices from the third lumbar vertebra. The radiographs and photographs were digitized and the geometric properties of the trabecular architecture were then determined with a digital images analysis technique. Information on the compressive strength and ash density of the vertebral body was also available. Results: The geometric properties of both radiographs and photographs could be measured with a high degree of reliability (Cronbach's α>0.85). Agreement between the radiographic and photographic approaches was mediocre as only the radiographic measurements showed insignificant correlations (p<0.05) with the biomechanical characteristics. We suggest that optical phenomena may result in the significant correlations between the photographs and the biomechanical characteristics. Conclusion: For digital image processing, radiography offers a superior description of the architecture of trabecular bone to that offered by photography. (orig.)

  17. Anomalous hydrodynamics of Weyl materials

    Science.gov (United States)

    Monteiro, Gustavo; Abanov, Alexander

    Kinetic theory is a useful tool to study transport in Weyl materials when the band-touching points are hidden inside a Fermi surface. It accounts, for example, for the negative magnetoresistance caused by the chiral magnetic effect and quantum oscillations (SdH effect) in the magnetoresistance together within the same framework. As an alternative approach to kinetic theory we also consider the regime of strong interactions where hydrodynamics can be applicable. A variational principle of these hydrodynamic equations can be found in and provide a natural framework to study hydrodynamic surface modes which correspond to the strongly-interacting physics signature of Fermi arcs. G.M. acknowledges the financial support from FAPESP.

  18. SPECIAL RELATIVISTIC HYDRODYNAMICS WITH GRAVITATION

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Jai-chan [Department of Astronomy and Atmospheric Sciences, Kyungpook National University, Daegu (Korea, Republic of); Noh, Hyerim [Korea Astronomy and Space Science Institute, Daejon (Korea, Republic of)

    2016-12-20

    Special relativistic hydrodynamics with weak gravity has hitherto been unknown in the literature. Whether such an asymmetric combination is possible has been unclear. Here, the hydrodynamic equations with Poisson-type gravity, considering fully relativistic velocity and pressure under the weak gravity and the action-at-a-distance limit, are consistently derived from Einstein’s theory of general relativity. An analysis is made in the maximal slicing, where the Poisson’s equation becomes much simpler than our previous study in the zero-shear gauge. Also presented is the hydrodynamic equations in the first post-Newtonian approximation, now under the general hypersurface condition. Our formulation includes the anisotropic stress.

  19. Similarity flows in relativistic hydrodynamics

    International Nuclear Information System (INIS)

    Blaizot, J.P.; Ollitrault, J.Y.

    1986-01-01

    In ultra-relativistic heavy ion collisions, one expects in particular to observe a deconfinement transition leading to a formation of quark gluon plasma. In the framework of the hydrodynamic model, experimental signatures of such a plasma may be looked for as observable consequences of a first order transition on the evolution of the system. In most of the possible scenario, the phase transition is accompanied with discontinuities in the hydrodynamic flow, such as shock waves. The method presented in this paper has been developed to treat without too much numerical effort such discontinuous flow. It relies heavily on the use of similarity solutions of the hydrodynamic equations

  20. The RAGE radiation-hydrodynamic code

    International Nuclear Information System (INIS)

    Gittings, Michael; Clover, Michael; Betlach, Thomas; Byrne, Nelson; Ranta, Dale; Weaver, Robert; Coker, Robert; Dendy, Edward; Hueckstaedt, Robert; New, Kim; Oakes, W Rob; Stefan, Ryan

    2008-01-01

    We describe RAGE, the 'radiation adaptive grid Eulerian' radiation-hydrodynamics code, including its data structures, its parallelization strategy and performance, its hydrodynamic algorithm(s), its (gray) radiation diffusion algorithm, and some of the considerable amount of verification and validation efforts. The hydrodynamics is a basic Godunov solver, to which we have made significant improvements to increase the advection algorithm's robustness and to converge stiffnesses in the equation of state. Similarly, the radiation transport is a basic gray diffusion, but our treatment of the radiation-material coupling, wherein we converge nonlinearities in a novel manner to allow larger timesteps and more robust behavior, can be applied to any multi-group transport algorithm

  1. Smoothed Particle Hydrodynamics Coupled with Radiation Transfer

    Science.gov (United States)

    Susa, Hajime

    2006-04-01

    We have constructed a brand-new radiation hydrodynamics solver based upon Smoothed Particle Hydrodynamics, which works on a parallel computer system. The code is designed to investigate the formation and evolution of first-generation objects at z ≳ 10, where the radiative feedback from various sources plays important roles. The code can compute the fraction of chemical species e, H+, H, H-, H2, and H+2 by by fully implicit time integration. It also can deal with multiple sources of ionizing radiation, as well as radiation at Lyman-Werner band. We compare the results for a few test calculations with the results of one-dimensional simulations, in which we find good agreements with each other. We also evaluate the speedup by parallelization, which is found to be almost ideal, as long as the number of sources is comparable to the number of processors.

  2. Fluctuating hydrodynamics for ionic liquids

    Energy Technology Data Exchange (ETDEWEB)

    Lazaridis, Konstantinos [Department of Mathematics and Statistics, Washington State University, Pullman, 99163 (United States); Wickham, Logan [Department of Computer Science, Washington State University, Richland, 99354 (United States); Voulgarakis, Nikolaos, E-mail: n.voulgarakis@wsu.edu [Department of Mathematics and Statistics, Washington State University, Pullman, 99163 (United States)

    2017-04-25

    We present a mean-field fluctuating hydrodynamics (FHD) method for studying the structural and transport properties of ionic liquids in bulk and near electrified surfaces. The free energy of the system consists of two competing terms: (1) a Landau–Lifshitz functional that models the spontaneous separation of the ionic groups, and (2) the standard mean-field electrostatic interaction between the ions in the liquid. The numerical approach used to solve the resulting FHD-Poisson equations is very efficient and models thermal fluctuations with remarkable accuracy. Such density fluctuations are sufficiently strong to excite the experimentally observed spontaneous formation of liquid nano-domains. Statistical analysis of our simulations provides quantitative information about the properties of ionic liquids, such as the mixing quality, stability, and the size of the nano-domains. Our model, thus, can be adequately parameterized by directly comparing our prediction with experimental measurements and all-atom simulations. Conclusively, this work can serve as a practical mathematical tool for testing various theories and designing more efficient mixtures of ionic liquids. - Highlights: • A new fluctuating hydrodynamics method for ionic liquids. • Description of ionic liquid morphology in bulk and near electrified surfaces. • Direct comparison with experimental measurements.

  3. Modelling hydrodynamic parameters to predict flow assisted corrosion

    International Nuclear Information System (INIS)

    Poulson, B.; Greenwell, B.; Chexal, B.; Horowitz, J.

    1992-01-01

    During the past 15 years, flow assisted corrosion has been a worldwide problem in the power generating industry. The phenomena is complex and depends on environment, material composition, and hydrodynamic factors. Recently, modeling of flow assisted corrosion has become a subject of great importance. A key part of this effort is modeling the hydrodynamic aspects of this issue. This paper examines which hydrodynamic parameter should be used to correlate the occurrence and rate of flow assisted corrosion with physically meaningful parameters, discusses ways of measuring the relevant hydrodynamic parameter, and describes how the hydrodynamic data is incorporated into the predictive model

  4. Clinical and radiographic evaluation of Portland cement added to radiopacifying agents in primary molar pulpotomies.

    Science.gov (United States)

    Lourenço Neto, N; Marques, N C T; Fernandes, A P; Hungaro Duarte, M A; Abdo, R C C; Machado, M A A M; Oliveira, T M

    2015-10-01

    This was to evaluate the clinical and radiographic outcomes of Portland cement (PC) added to radiopacifying agents in primary molar pulpotomies. Thirty primary mandibular molars of children aged between 5 and 9 years were randomly assigned to the following groups: PC; PC with iodoform (PC + CHI(3)); PC with zirconium oxide (PC + ZrO(2)) and treated by pulpotomy technique. Clinical and radiographic follow-up assessments were performed at 6, 12 and 24 months. Statistical analysis was performed by Fisher's exact test (P < 0.05). The clinical and radiographic evaluations showed 100 % success rates, and the results showed no statistically significant difference between groups. According to this study, PC added to radiopacifying agents exhibited satisfactory clinical and radiographic results in primary molar pulpotomies.

  5. Radiographical measurements for distal intra-articular fractures of the radius using plain radiographs and cone beam computed tomography images

    Energy Technology Data Exchange (ETDEWEB)

    Suojaervi, Nora; Lindfors, N. [Helsinki University Central Hospital, Department of Hand Surgery, Helsinki (Finland); Sillat, T.; Koskinen, S.K. [HUS Helsinki Medical Imaging Center, Helsinki University Central Hospital, Department of Radiology, Helsinki (Finland)

    2015-12-15

    Operative treatment of an intra-articular distal radius fracture is one of the most common procedures in orthopedic and hand surgery. The intra- and interobserver agreement of common radiographical measurements of these fractures using cone beam computed tomography (CBCT) and plain radiographs were evaluated. Thirty-seven patients undergoing open reduction and volar fixation for a distal radius fracture were studied. Two radiologists analyzed the preoperative radiographs and CBCT images. Agreement of the measurements was subjected to intra-class correlation coefficient and the Bland-Altman analyses. Plain radiographs provided a slightly poorer level of agreement. For fracture diastasis, excellent intraobserver agreement was achieved for radiographs and good or excellent agreement for CBCT, compared to poor interobserver agreement (ICC 0.334) for radiographs and good interobserver agreement (ICC 0.621) for CBCT images. The Bland-Altman analyses indicated a small mean difference between the measurements but rather large variation using both imaging methods, especially in angular measurements. For most of the measurements, radiographs do well, and may be used in clinical practice. Two different measurements by the same reader or by two different readers can lead to different decisions, and therefore a standardization of the measurements is imperative. More detailed analysis of articular surface needs cross-sectional imaging modalities. (orig.)

  6. Radiographical measurements for distal intra-articular fractures of the radius using plain radiographs and cone beam computed tomography images.

    Science.gov (United States)

    Suojärvi, Nora; Sillat, T; Lindfors, N; Koskinen, S K

    2015-12-01

    Operative treatment of an intra-articular distal radius fracture is one of the most common procedures in orthopedic and hand surgery. The intra- and interobserver agreement of common radiographical measurements of these fractures using cone beam computed tomography (CBCT) and plain radiographs were evaluated. Thirty-seven patients undergoing open reduction and volar fixation for a distal radius fracture were studied. Two radiologists analyzed the preoperative radiographs and CBCT images. Agreement of the measurements was subjected to intra-class correlation coefficient and the Bland-Altman analyses. Plain radiographs provided a slightly poorer level of agreement. For fracture diastasis, excellent intraobserver agreement was achieved for radiographs and good or excellent agreement for CBCT, compared to poor interobserver agreement (ICC 0.334) for radiographs and good interobserver agreement (ICC 0.621) for CBCT images. The Bland-Altman analyses indicated a small mean difference between the measurements but rather large variation using both imaging methods, especially in angular measurements. For most of the measurements, radiographs do well, and may be used in clinical practice. Two different measurements by the same reader or by two different readers can lead to different decisions, and therefore a standardization of the measurements is imperative. More detailed analysis of articular surface needs cross-sectional imaging modalities.

  7. Assessment of radiation protection practices among radiographers in Lagos, Nigeria.

    Science.gov (United States)

    Eze, Cletus Uche; Abonyi, Livinus Chibuzo; Njoku, Jerome; Irurhe, Nicholas Kayode; Olowu, Oluwabola

    2013-11-01

    Use of ionising radiation in diagnostic radiography could lead to hazards such as somatic and genetic damages. Compliance to safe work and radiation protection practices could mitigate such risks. The aim of the study was to assess the knowledge and radiation protection practices among radiographers in Lagos, Nigeria. The study was a prospective cross sectional survey. Convenience sampling technique was used to select four x-ray diagnostic centres in four tertiary hospitals in Lagos metropolis. Data were analysed with Epi- info software, version 3.5.1. Average score on assessment of knowledge was 73%. Most modern radiation protection instruments were lacking in all the centres studied. Application of shielding devices such as gonad shield for protection was neglected mostly in government hospitals. Most x-ray machines were quite old and evidence of quality assurance tests performed on such machines were lacking. Radiographers within Lagos metropolis showed an excellent knowledge of radiation protection within the study period. Adherence to radiation protection practices among radiographers in Lagos metropolis during the period studied was, however, poor. Radiographers in Lagos, Nigeria should embrace current trends in radiation protection and make more concerted efforts to apply their knowledge in protecting themselves and patients from harmful effects of ionising radiation.

  8. Reliability of radiographic observations recorded on a proforma measured using inter- and intra-observer variation: a preliminary study.

    Science.gov (United States)

    Saunders, M B; Gulabivala, K; Holt, R; Kahan, R S

    2000-05-01

    The aim of this preliminary study was to test the reliability of radiographic evaluation of features of endodontic interest using a newly devised data collection system. Twelve endodontic MSc postgraduate students and one specialist endodontist examined sample radiographs derived from a random selection of 42 patients seen previously on an Endodontic New Patient Clinic (EDI). Each student examined a random selection of 8-9 roots on periapical radiographs of single- and multirooted teeth, with and without previous root canal therapy and 3-4 dental panoramic tomograms (DPTs). A total of 100 roots were examined. A proforma was used to record observations on 67 radiographic features using predefined criteria. Intra-observer agreement was tested by asking the students to re-examine the radiographs. The principle investigator and the specialist endodontist examined the same radiographs and devised a Gold Standard using the same criteria. This was compared with the student assessments to determine inter-observer variation. The postgraduates then attended a revision session on the use of the form. Each student subsequently examined 8-9 different roots from the pool of radiographs. A further assessment of inter-observer variation was made by comparing these observations with the Gold Standard. Of the 67 radiographic features, only 25 had sufficient response to allow statistical analysis. Kappa values for intra- and inter-observer variation were estimated. These varied depending on the particular radiographic feature being assessed. Fifteen out of 25 intra-observer recordings showed 'good' or 'very good' Kappa agreement, but only three out of 25 inter-observer observations achieved 'good' or 'very good' values. Inter-observer variation was improved following the revision session with 16 out of 25 observations achieving 'good' or 'very good' Kappa agreement. Modification to the proforma, the criteria used, and training for radiographic assessment were considered necessary to

  9. Final Report for 'Verification and Validation of Radiation Hydrodynamics for Astrophysical Applications'

    International Nuclear Information System (INIS)

    Zingale, M.; Howell, L.H.

    2010-01-01

    The motivation for this work is to gain experience in the methodology of verification and validation (V and V) of astrophysical radiation hydrodynamics codes. In the first period of this work, we focused on building the infrastructure to test a single astrophysical application code, Castro, developed in collaboration between Lawrence Livermore National Laboratory (LLNL) and Lawrence Berkeley Laboratory (LBL). We delivered several hydrodynamic test problems, in the form of coded initial conditions and documentation for verification, routines to perform data analysis, and a generalized regression test suite to allow for continued automated testing. Astrophysical simulation codes aim to model phenomena that elude direct experimentation. Our only direct information about these systems comes from what we observe, and may be transient. Simulation can help further our understanding by allowing virtual experimentation of these systems. However, to have confidence in our simulations requires us to have confidence in the tools we use. Verification and Validation is a process by which we work to build confidence that a simulation code is accurately representing reality. V and V is a multistep process, and is never really complete. Once a single test problem is working as desired (i.e. that problem is verified), one wants to ensure that subsequent code changes do not break that test. At the same time, one must also search for new verification problems that test the code in a new way. It can be rather tedious to manually retest each of the problems, so before going too far with V and V, it is desirable to have an automated test suite. Our project aims to provide these basic tools for astrophysical radiation hydrodynamics codes.

  10. Radiographic manifestations of hypochondroplasia

    Energy Technology Data Exchange (ETDEWEB)

    Heselson, N G; Cremin, B J [Groote Schuur Hospital, Cape Town (South Africa); Beighton, P

    1979-01-01

    Hypochrondroplasia is an inherited skeletal dysplasia that resembles achondroplasia in mild degree. Radiographic manifestations encountered in 12 affected individuals in South Africa include slight shortening of all segments of the tubular bones, moderate caudal diminution of the lumbar interpedicular distances, increased lumbar lordosis with cacral tilt and distal prolongation of the fibular. Hypochondroplasia can be distinguished from other osteochondrodystrophies such as achondroplasia, pseudo-achondroplasia and metaphyseal chondroplasia by the recognition of it clinical and radiographic manifestations.

  11. Hydrodynamic interactions in active colloidal crystal microrheology.

    Science.gov (United States)

    Weeber, R; Harting, J

    2012-11-01

    In dense colloids it is commonly assumed that hydrodynamic interactions do not play a role. However, a found theoretical quantification is often missing. We present computer simulations that are motivated by experiments where a large colloidal particle is dragged through a colloidal crystal. To qualify the influence of long-ranged hydrodynamics, we model the setup by conventional Langevin dynamics simulations and by an improved scheme with limited hydrodynamic interactions. This scheme significantly improves our results and allows to show that hydrodynamics strongly impacts the development of defects, the crystal regeneration, as well as the jamming behavior.

  12. Consultant radiographers: Profile of the first generation

    International Nuclear Information System (INIS)

    Forsyth, Lesley J.; Maehle, Valerie

    2010-01-01

    Aim: The aim of this research is to examine the profile of first generation consultant radiographers: their demographics, educational backgrounds, qualifications and training, career experience and progression, teaching, lecturing and research activities. Method: Participant recruitment was drawn from the Society and College of Radiographers consultant radiographer group. Data collection involved a self-administered paper based and web based questionnaire. Results: Participant response rate of 55% (n = 11). Conclusions: The profile of the first consultant radiographer cohort reflects a diverse and eclectic mix. While some aspects of their development such as educational background, clinical training and skills enhancement are comparable to nurse consultants, clinical experience and employment history show some differences. Commitment to development of expert clinical skills is evident within the profile of the first generation cohort of consultant radiographers however research and leadership training are not strong features.

  13. Consultant radiographers: Profile of the first generation

    Energy Technology Data Exchange (ETDEWEB)

    Forsyth, Lesley J., E-mail: l.forsyth@rgu.ac.u [School of Health Sciences, Robert Gordon University, Aberdeen, AB10 7QG (United Kingdom); Maehle, Valerie [Faculty of Health and Social Care, Robert Gordon University, Aberdeen, AB10 7QG (United Kingdom)

    2010-11-15

    Aim: The aim of this research is to examine the profile of first generation consultant radiographers: their demographics, educational backgrounds, qualifications and training, career experience and progression, teaching, lecturing and research activities. Method: Participant recruitment was drawn from the Society and College of Radiographers consultant radiographer group. Data collection involved a self-administered paper based and web based questionnaire. Results: Participant response rate of 55% (n = 11). Conclusions: The profile of the first consultant radiographer cohort reflects a diverse and eclectic mix. While some aspects of their development such as educational background, clinical training and skills enhancement are comparable to nurse consultants, clinical experience and employment history show some differences. Commitment to development of expert clinical skills is evident within the profile of the first generation cohort of consultant radiographers however research and leadership training are not strong features.

  14. Interpretation and evaluation of radiograph

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    After digestion, the interpreter must interpreted and evaluate the image on film, usually many radiograph stuck in this step, if there is good density, so there are no problem. This is a final stage of radiography work and this work must be done by level two or three radiographer. This is a final stages before the radiographer give a result to their customer for further action. The good interpreter must know what kind of artifact, is this artifact are dangerous or not and others. In this chapter, the entire artifact that usually showed will be discussed briefly with the good illustration and picture to make the reader understand and know the type of artifact that exists.

  15. Numerical Hydrodynamics in General Relativity

    Directory of Open Access Journals (Sweden)

    Font José A.

    2003-01-01

    Full Text Available The current status of numerical solutions for the equations of ideal general relativistic hydrodynamics is reviewed. With respect to an earlier version of the article, the present update provides additional information on numerical schemes, and extends the discussion of astrophysical simulations in general relativistic hydrodynamics. Different formulations of the equations are presented, with special mention of conservative and hyperbolic formulations well-adapted to advanced numerical methods. A large sample of available numerical schemes is discussed, paying particular attention to solution procedures based on schemes exploiting the characteristic structure of the equations through linearized Riemann solvers. A comprehensive summary of astrophysical simulations in strong gravitational fields is presented. These include gravitational collapse, accretion onto black holes, and hydrodynamical evolutions of neutron stars. The material contained in these sections highlights the numerical challenges of various representative simulations. It also follows, to some extent, the chronological development of the field, concerning advances on the formulation of the gravitational field and hydrodynamic equations and the numerical methodology designed to solve them.

  16. The RAGE radiation-hydrodynamic code

    Energy Technology Data Exchange (ETDEWEB)

    Gittings, Michael; Clover, Michael; Betlach, Thomas; Byrne, Nelson; Ranta, Dale [Science Applications International Corp. MS A-1, 10260 Campus Point Drive, San Diego, CA 92121 (United States); Weaver, Robert; Coker, Robert; Dendy, Edward; Hueckstaedt, Robert; New, Kim; Oakes, W Rob [Los Alamos National Laboratory, MS T087, PO Box 1663, Los Alamos, NM 87545 (United States); Stefan, Ryan [TaylorMade-adidas Golf, 5545 Fermi Court, Carlsbad, CA 92008-7324 (United States)], E-mail: michael.r.clover@saic.com

    2008-10-01

    We describe RAGE, the 'radiation adaptive grid Eulerian' radiation-hydrodynamics code, including its data structures, its parallelization strategy and performance, its hydrodynamic algorithm(s), its (gray) radiation diffusion algorithm, and some of the considerable amount of verification and validation efforts. The hydrodynamics is a basic Godunov solver, to which we have made significant improvements to increase the advection algorithm's robustness and to converge stiffnesses in the equation of state. Similarly, the radiation transport is a basic gray diffusion, but our treatment of the radiation-material coupling, wherein we converge nonlinearities in a novel manner to allow larger timesteps and more robust behavior, can be applied to any multi-group transport algorithm.

  17. Usefulness of prone cross-table lateral radiographs in vertebral compression fractures.

    Science.gov (United States)

    Cho, Jae Hwan; Shin, Sang Ik; Lee, Jae Hyup; Yeom, Jin Sup; Chang, Bong-Soon; Lee, Choon-Ki

    2013-09-01

    Dynamic radiographs are recommended to investigate non-healing evidence such as the dynamic mobility or intravertebral clefts in osteoporotic vertebral compression fractures (VCFs). However, it is difficult to examine standing flexion and extension lateral radiographs due to severe pain. The use of prone cross-table lateral radiographs (PrLRs) as a diagnostic tool has never been proposed to our knowledge. The purpose of this study is to clarify the usefulness of PrLRs in diagnosis and treatment of VCFs. We reviewed 62 VCF patients examined with PrLRs between January 1, 2008 and June 30, 2011. To compare the degree of pain provoked between standing extension lateral radiographs (StLRs) and PrLRs, numeric rating scale (NRS) scores were assessed and compared by a paired t-test. Vertebroplasty was done for 40 patients and kyphoplasty was done for 9 patients with routine manners. To assess the degree of postural reduction, vertebral wedge angles (VWA) and vertebral height ratios (VHR) were calculated by using preoperative StLRs, PrLRs, and postoperative lateral radiographs. Two variables derived from changes in VWA and VHR between preoperative and postoperative radiographs were compared by a paired t-test. The average NRS scores were 6.23 ± 1.67 in StLRs and 5.18 ± 1.47 in PrLRs. The degree of pain provocation was lower in using PrLRs than StLRs (p < 0.001). The average changes of VWA between preoperative and postoperative status were 5.24° ± 6.16° with PrLRs and 3.46° ± 3.47° with StLRs. The average changes of VHR were 0.248 ± 0.178 with PrLRs and 0.148 ± 0.161 with StLRs. The comparisons by two variables showed significant differences for both parameters (p = 0.021 and p < 0.001, respectively). The postoperative radiological status was reflected more precisely when using PrLRs than StLRs. In comparison with StLR, the PrLR was more accurate in predicting the degree of restoration of postoperative vertebral heights and wedge angles, and provoked less pain

  18. Development of a Dynamic Spot Size Diagnostic for Flash Radiographic X-Ray Sources

    International Nuclear Information System (INIS)

    Droemer, D. W.; Lutz, S.; Devore, D.; Rovang, D.; Portillo, S.; Maenchen, J.

    2003-01-01

    There has been considerable work in recent years in the development of high-brightness, high-dose flash x-ray radiographic sources. Spot size is one of several parameters that helps characterize source performance and provides a figure of merit to assess the suitability of various sources to specific experimental requirements. Time-integrated spot-size measurements using radiographic film and a high-Z rolled-edge object have been used for several years with great success. The Advanced Radiographic Technologies program thrust to improve diode performance requires extending both modeling and experimental measurements into the transient time domain. A new Time Resolved Spot Detector (TRSD) is under development to provide this information. In this paper we report the initial results of the performance of a 148-element scintillating fiber array that is fiber-optically coupled to a gated streak camera. Spatial and temporal resolution results are discussed and the data obtained FR-om the Sand ia National Laboratories (SNL) RITS-3 (Radiographic Integrated Test Stand) accelerator are presented

  19. Hydrodynamic Forces on Composite Structures

    Science.gov (United States)

    2014-06-01

    NAVAL POSTGRADUATE SCHOOL MONTEREY, CALIFORNIA THESIS Approved for public release; distribution is unlimited HYDRODYNAMIC ...Thesis 4. TITLE AND SUBTITLE HYDRODYNAMIC FORCES ON COMPOSITE STRUCTURES 5. FUNDING NUMBERS 6. AUTHOR(S) Scott C. Millhouse 7. PERFORMING...angles yields different free surface effects including vortices and the onset of cavitation . 14. SUBJECT TERMS Fluid structure interaction, FSI, finite

  20. Anisotropic hydrodynamics for conformal Gubser flow

    Energy Technology Data Exchange (ETDEWEB)

    Strickland, Michael; Nopoush, Mohammad [Kent State University, Kent OH 44242 (United States); Ryblewski, Radoslaw [The H. Niewodniczański Institute of Nuclear Physics, Polish Academy of Sciences, PL-31342 Kraków (Poland)

    2016-12-15

    In this proceedings contribution, we review the exact solution of the anisotropic hydrodynamics equations for a system subject to Gubser flow. For this purpose, we use the leading-order anisotropic hydrodynamics equations which assume that the distribution function is ellipsoidally symmetric in local-rest-frame momentum. We then prove that the SO(3){sub q} symmetry in de Sitter space constrains the anisotropy tensor to be of spheroidal form with only one independent anisotropy parameter remaining. As a consequence, the exact solution reduces to the problem of solving two coupled non-linear differential equations. We show that, in the limit that the relaxation time goes to zero, one obtains Gubser's ideal hydrodynamic solution and, in the limit that the relaxation time goes to infinity, one obtains the exact free streaming solution obtained originally by Denicol et al. For finite relaxation time, we solve the equations numerically and compare to the exact solution of the relaxation-time-approximation Boltzmann equation subject to Gubser flow. Using this as our standard, we find that anisotropic hydrodynamics describes the spatio-temporal evolution of the system better than all currently known dissipative hydrodynamics approaches.

  1. Anisotropic hydrodynamics for conformal Gubser flow

    International Nuclear Information System (INIS)

    Strickland, Michael; Nopoush, Mohammad; Ryblewski, Radoslaw

    2016-01-01

    In this proceedings contribution, we review the exact solution of the anisotropic hydrodynamics equations for a system subject to Gubser flow. For this purpose, we use the leading-order anisotropic hydrodynamics equations which assume that the distribution function is ellipsoidally symmetric in local-rest-frame momentum. We then prove that the SO(3)_q symmetry in de Sitter space constrains the anisotropy tensor to be of spheroidal form with only one independent anisotropy parameter remaining. As a consequence, the exact solution reduces to the problem of solving two coupled non-linear differential equations. We show that, in the limit that the relaxation time goes to zero, one obtains Gubser's ideal hydrodynamic solution and, in the limit that the relaxation time goes to infinity, one obtains the exact free streaming solution obtained originally by Denicol et al. For finite relaxation time, we solve the equations numerically and compare to the exact solution of the relaxation-time-approximation Boltzmann equation subject to Gubser flow. Using this as our standard, we find that anisotropic hydrodynamics describes the spatio-temporal evolution of the system better than all currently known dissipative hydrodynamics approaches.

  2. Diagnostic ability of the periapical radiographs and digital image in the detection of the artificial proximal caries

    International Nuclear Information System (INIS)

    Heo, Min Suk; You, Dong Soo

    1994-01-01

    Recently, the digital image was introduced into radiological image. The digital image has the power of contrast enhancement, histogram control, and other digitally enhancement. At the point of the resolution, periapical radiograph is superior to the digital image, but enhanced digital procedure improves the diagnostic ability of the digital image. The purpose of this study was to evaluate the diagnostic ability of artificial proximal caries in conventional radiographs, digital radiographs and enhanced digital radiographs (histogram specification). ROC (Receiver Operating Characteristic) analysis and paired t-test were used for the evaluation of detectability, and following results were acquired: 1. The mean ROC area of conventional radiographs was 0.9274. 2. The mean ROC area of unenhanced digital image was 0.9168. 3. The mean ROC area of enhanced digital image was 0.9339. 4. The diagnostic ability of three imaging methods was not significant difference (p>0.05). So, the digital images had similar diagnostic ability of artificial proximal caries to conventional radiographs. If properly enhanced digital image, it may be superior to conventional radiographs.

  3. Radiographic signs and diagnosis of dental disease

    International Nuclear Information System (INIS)

    Bellows, J.

    1993-01-01

    Dental radiographs are critical for the complete assessment and treatment of dental diseases. Dental radiography is commonly used to evaluate congenital dental defects, periodontal disease, orthodontic manipulations, oral tumors, endodontic treatments, oral trauma, and any situation where an abnormality is suspected. Although standard radiographic equipment and film can be used to produce dental radiographs, dental X-ray equipment and film provide superior quality images and greater convenience of animal patient positioning. An understanding of normal dental radiographic anatomy is important when interpreting dental radiographs. Stage III periodontitis is the earliest stage of periodontal disease at which radiographic abnormalities become apparent. Bone loss associated with periodontal disease can be classified as either horizontal or vertical. Periapical radiolucencies can represent granulomas, cysts, or abscesses, whereas periapical radiodensities may represent sclerotic bone or condensing osteitis. Lytic lesions of the bone of the jaw often represent oral neoplasms. Neoplasms also can displace or disrupt teeth in the dental arch. Resorptive lesions can be external or internal and appear as radiolucent areas involving the external surface of the root or the pulp cavity, respectively. Feline dental resorptive lesions, also known as odontoclastic resorptions, are a specific form of dental resorptive lesions unique to cats

  4. Radiographic heart-volume estimation in normal cats

    International Nuclear Information System (INIS)

    Ahlberg, N.E.; Hansson, K.; Svensson, L.; Iwarsson, K.

    1989-01-01

    Heart volume mensuration was evaluated on conventional radiographs from eight normal cats in different body positions using computed tomography (CT). Heart volumes were calculated from orthogonal thoracic radiographs in ventral and dorsal recumbency and from radiographs exposed with a vertical X-ray beam in dorsal and lateral recumbency using the formula for an ellipsoid body. Heart volumes were also estimated with CT in ventral, dorsal, right lateral and left lateral recumbency. No differences between heart volumes from CT in ventral recumbency and those from CT in right and left lateral recumbency were seen. In dorsal recumbency, however, significantly lower heart volumes were obtained. Heart volumes from CT in ventral recumbency were similar to those from radiographs in ventral and dorsal recumbency and dorsal/left lateral recumbency. Close correlation was also demonstrated between heart volumes from radiographs in dorsal/ left lateral recumbency and body weights of the eight cats

  5. Small systems – hydrodynamics

    Energy Technology Data Exchange (ETDEWEB)

    Bożek, Piotr, E-mail: piotr.bozek@fis.agh.edu.pl

    2016-12-15

    The scenario assuming a collective expansion stage in collisions of small systems, p-A, d-Au, and {sup 3}He-Au is discussed. A review of the observables predicted in relativistic hydrodynamic models in comparison with experimental data is presented, with arguments indicating the presence of collective expansion. The limits of applicability of the hydrodynamic model are addressed. We briefly indicate possible applications of the collective flow in small systems to study the space-time dynamics at very small scales in relativistic collisions.

  6. Relativistic conformal magneto-hydrodynamics from holography

    International Nuclear Information System (INIS)

    Buchbinder, Evgeny I.; Buchel, Alex

    2009-01-01

    We use the AdS/CFT correspondence to study first-order relativistic viscous magneto-hydrodynamics of (2+1)-dimensional conformal magnetic fluids. It is shown that the first order magneto-hydrodynamics constructed following Landau and Lifshitz from the positivity of the entropy production is inconsistent. We propose additional contributions to the entropy motivated dissipative current and, correspondingly, new dissipative transport coefficients. We use the strongly coupled M2-brane plasma in external magnetic field to show that the new magneto-hydrodynamics leads to self-consistent results in the shear and sound wave channels.

  7. Dileptons from transport and hydrodynamical models

    International Nuclear Information System (INIS)

    Huovinen, P.; Koch, V.

    2000-01-01

    Transport and hydrodynamical models used to describe the expansion stage of a heavy-ion collision at the CERN SPS give different dilepton spectrum even if they are tuned to reproduce the observed hadron spectra. To understand the origin of this difference we compare the dilepton emission from transport and hydrodynamical models using similar initial states in both models. We find that the requirement of pion number conservation in a hydrodynamical model does not change the dilepton emission. Also the mass distribution from the transport model indicates faster cooling and longer lifetime of the fireball

  8. Review and evaluation of technology, equipment, codes and standards for digitization of industrial radiographic film

    International Nuclear Information System (INIS)

    1992-05-01

    This reports contains a review and evaluation of the technology, equipment, and codes and standards related to the digitization of industrial radiographic film. The report presents recommendations and equipment-performance specifications that will allow the digitization of radiographic film from nuclear power plant components in order to produce faithful reproductions of flaw images of interest on the films. Justification for the specifications selected are provided. Performance demonstration tests for the digitization process are required and criteria for such tests is presented. Also several comments related to implementation of the technology are presented and discussed

  9. Determining the hydrodynamic indices of contractions

    International Nuclear Information System (INIS)

    Blagov, Eh.E.

    2002-01-01

    The new dependences, making it possible only by measuring the flow rate and pressure drop on the contraction device (CD) with the known geometry, including the regulatory organ, in the non-crisis mode of the turbulent flow to calculate all the hydrodynamic indices of this device, including the pressure reduction in the jet contraction, are obtained. This simplifies and accelerates the CD hydraulic tests of all types. The new methodology for determining the cavitation factual start on the CD is proposed [ru

  10. Diagnostic Yield of Recommendations for Chest CT Examination Prompted by Outpatient Chest Radiographic Findings

    Science.gov (United States)

    Harvey, H. Benjamin; Gilman, Matthew D.; Wu, Carol C.; Cushing, Matthew S.; Halpern, Elkan F.; Zhao, Jing; Pandharipande, Pari V.; Shepard, Jo-Anne O.

    2015-01-01

    Purpose To evaluate the diagnostic yield of recommended chest computed tomography (CT) prompted by abnormalities detected on outpatient chest radiographic images. Materials and Methods This HIPAA-compliant study had institutional review board approval; informed consent was waived. Reports of all outpatient chest radiographic examinations performed at a large academic center during 2008 (n = 29 138) were queried to identify studies that included a recommendation for a chest CT imaging. The radiology information system was queried for these patients to determine if a chest CT examination was obtained within 1 year of the index radiographic examination that contained the recommendation. For chest CT examinations obtained within 1 year of the index chest radiographic examination and that met inclusion criteria, chest CT images were reviewed to determine if there was an abnormality that corresponded to the chest radiographic finding that prompted the recommendation. All corresponding abnormalities were categorized as clinically relevant or not clinically relevant, based on whether further work-up or treatment was warranted. Groups were compared by using t test and Fisher exact test with a Bonferroni correction applied for multiple comparisons. Results There were 4.5% (1316 of 29138 [95% confidence interval {CI}: 4.3%, 4.8%]) of outpatient chest radiographic examinations that contained a recommendation for chest CT examination, and increasing patient age (P recommendation for chest CT examination. Of patients within this subset who met inclusion criteria, 65.4% (691 of 1057 [95% CI: 62.4%, 68.2%) underwent a chest CT examination within the year after the index chest radiographic examination. Clinically relevant corresponding abnormalities were present on chest CT images in 41.4% (286 of 691 [95% CI: 37.7%, 45.2%]) of cases, nonclinically relevant corresponding abnormalities in 20.6% (142 of 691 [95% CI: 17.6%, 23.8%]) of cases, and no corresponding abnormalities in 38

  11. Reader performance in detection of pneumothorax on conventional chest films versus computed radiographs

    International Nuclear Information System (INIS)

    Elam, E.A.; Hillman, B.J.; Fajardo, L.L.

    1990-01-01

    This paper evaluates the suitability of digital radiography for the detection of pneumothoraces, we compared radiologist' performance in four interpretation settings: conventional film-screen (FS) chest radiographs; small-format (8 x 6.5-inch) computed radiography (CR) (Toshiba); large-format (14 x 17-inch) CR; and CR images viewed on a digital workstation. Twenty-three frontal-view chest radiographs with pneumothoraces and 22 other chest radiographs, either normal or showing miscellaneous abnormalities, were read by six board-certified radiologist in each interpretation setting. We compared the sensitivity, specificity, and receiver operating characteristic (ROC) performances they achieved among the interpretation settings with the use of sequential paired t tests. To date, four readers have completed their reading of both the FS and the small-format CR films

  12. Analytic approaches to relativistic hydrodynamics

    Energy Technology Data Exchange (ETDEWEB)

    Hatta, Yoshitaka

    2016-12-15

    I summarize our recent work towards finding and utilizing analytic solutions of relativistic hydrodynamic. In the first part I discuss various exact solutions of the second-order conformal hydrodynamics. In the second part I compute flow harmonics v{sub n} analytically using the anisotropically deformed Gubser flow and discuss its dependence on n, p{sub T}, viscosity, the chemical potential and the charge.

  13. Radiographic aspects of xeroradiography

    International Nuclear Information System (INIS)

    Rao, G.U.V.; Fatouros, P.P.

    1980-01-01

    The quality of a conventional radiographic image can be characterized in terms of five basic parameters; density, contrast, latitude, resolution and noise. Since xeroradiographic images exhibit very limited broad area contrasts, and image formation is predominantly due to edge enhancement, a straightforward description of image quality using the same five parameters is not adequate. A detailed study was made of the radiographic aspects of xeroradiography with special reference to mammography, and a summary of major findings to date with appropriate references to published papers is presented

  14. Radiologist perceptions of radiographer role development in Scotland

    Energy Technology Data Exchange (ETDEWEB)

    Forsyth, Lesley J. [School of Health Sciences, Robert Gordon University, Faculty of Health and Social Care, Garthdee Road, Garthdee, Aberdeen AB10 7QG (United Kingdom)]. E-mail: l.forsyth@rgu.ac.uk; Robertson, Elizabeth M. [Department of Radiology, Aberdeen Royal Infirmary, Foresterhill, Aberdeen AB25 2ZN (United Kingdom)]. E-mail: e.m.robertson@arh.grampian.scot.nhs.uk

    2007-02-15

    Aim: To survey the perceptions of the Scottish radiology community in relation to radiographer role development. Methods: A postal questionnaire was sent to all consultant radiologists recorded on the NHS Scotland database of consultants. Results: Response rate was 63%. (i) Respondents considered increased professional standing of radiographers, best use of manpower resources, reduced pressure on the service and improved recruitment and retention, as positive advantages of radiographer development. (ii) The potential impact on radiology specialist registrar training, lack of clear medico-legal responsibilities and radiographers recognising the limitations of their abilities were identified as the main areas of radiologist anxiety. (iii) Fifty-seven percent did not consider current post-registration radiography education and training resources adequate to underpin the requirement of developed roles. (iv) Barriers to radiographer development were identified as lack of radiography and radiology staff, suitable education, financial constraints, traditional views and resistance to change. (v) Eighty-two percent reported support for radiographer role development and willingness to participate actively in developments. Conclusion: Despite reservations Scottish radiologists are supportive of the development of radiography colleagues, however, guidance is required on the medico-legal and accountability aspects of radiographers assuming new roles. Radiologist involvement in education and training for new roles may increase their confidence and trust in radiographers to work within the limitations of their competency and training.

  15. Radiologist perceptions of radiographer role development in Scotland

    International Nuclear Information System (INIS)

    Forsyth, Lesley J.; Robertson, Elizabeth M.

    2007-01-01

    Aim: To survey the perceptions of the Scottish radiology community in relation to radiographer role development. Methods: A postal questionnaire was sent to all consultant radiologists recorded on the NHS Scotland database of consultants. Results: Response rate was 63%. (i) Respondents considered increased professional standing of radiographers, best use of manpower resources, reduced pressure on the service and improved recruitment and retention, as positive advantages of radiographer development. (ii) The potential impact on radiology specialist registrar training, lack of clear medico-legal responsibilities and radiographers recognising the limitations of their abilities were identified as the main areas of radiologist anxiety. (iii) Fifty-seven percent did not consider current post-registration radiography education and training resources adequate to underpin the requirement of developed roles. (iv) Barriers to radiographer development were identified as lack of radiography and radiology staff, suitable education, financial constraints, traditional views and resistance to change. (v) Eighty-two percent reported support for radiographer role development and willingness to participate actively in developments. Conclusion: Despite reservations Scottish radiologists are supportive of the development of radiography colleagues, however, guidance is required on the medico-legal and accountability aspects of radiographers assuming new roles. Radiologist involvement in education and training for new roles may increase their confidence and trust in radiographers to work within the limitations of their competency and training

  16. Brownian dynamics with hydrodynamic interactions

    International Nuclear Information System (INIS)

    Ermak, D.L.; McCammon, J.A.

    1978-01-01

    A method for simulating the Brownian dynamics of N particles with the inclusion of hydrodynamic interactions is described. The particles may also be subject to the usual interparticle or external forces (e.g., electrostatic) which have been included in previous methods for simulating Brownian dynamics of particles in the absence of hydrodynamic interactions. The present method is derived from the Langevin equations for the N particle assembly, and the results are shown to be consistent with the corresponding Fokker--Planck results. Sample calculations on small systems illustrate the importance of including hydrodynamic interactions in Brownian dynamics simulations. The method should be useful for simulation studies of diffusion limited reactions, polymer dynamics, protein folding, particle coagulation, and other phenomena in solution

  17. Effect of a tele-training programme on radiographers in the interpretation of CT colonography

    DEFF Research Database (Denmark)

    Lauridsen, Carsten; Lefere, Philippe; Gerke, Oke

    2012-01-01

    OBJECTIVE: To assess the performance of radiographers in CT colonography (CTC) after a tele-training programme, supervised by 2 experienced radiologists. MATERIALS AND METHODS: Five radiographers underwent training in CTC using a tele-training programme mainly based on the interpretation of 75...... training cases performed in the novice department. To evaluate the educational performance, each radiographer was tested on 20 test cases with 27 lesions >6mm (12: 6-9mm; 15: >10mm). Sensitivity, specificity and PPV for polyps ≥6mm and ≥10mm were calculated with point estimates and 95% confidence interval...... (95% CI). The results were compared by comparing 95% CI with a 5% significance level. RESULTS: In the training cases overall per-polyp sensitivity was 57% (95% CI 46.1-67.9) and 69.1% (95% CI 50.6-87.5) for lesions ≥6mm and ≥10mm, respectively. Overall per patient sensitivity, specificity and PPV were...

  18. Hydrodynamic Modeling and Its Application in AUC.

    Science.gov (United States)

    Rocco, Mattia; Byron, Olwyn

    2015-01-01

    The hydrodynamic parameters measured in an AUC experiment, s(20,w) and D(t)(20,w)(0), can be used to gain information on the solution structure of (bio)macromolecules and their assemblies. This entails comparing the measured parameters with those that can be computed from usually "dry" structures by "hydrodynamic modeling." In this chapter, we will first briefly put hydrodynamic modeling in perspective and present the basic physics behind it as implemented in the most commonly used methods. The important "hydration" issue is also touched upon, and the distinction between rigid bodies versus those for which flexibility must be considered in the modeling process is then made. The available hydrodynamic modeling/computation programs, HYDROPRO, BEST, SoMo, AtoB, and Zeno, the latter four all implemented within the US-SOMO suite, are described and their performance evaluated. Finally, some literature examples are presented to illustrate the potential applications of hydrodynamics in the expanding field of multiresolution modeling. © 2015 Elsevier Inc. All rights reserved.

  19. Two-fluid hydrodynamic model for semiconductors

    DEFF Research Database (Denmark)

    Maack, Johan Rosenkrantz; Mortensen, N. Asger; Wubs, Martijn

    2018-01-01

    The hydrodynamic Drude model (HDM) has been successful in describing the optical properties of metallic nanostructures, but for semiconductors where several different kinds of charge carriers are present an extended theory is required. We present a two-fluid hydrodynamic model for semiconductors...

  20. Chest radiographic findings in acute paraquat poisoning

    Energy Technology Data Exchange (ETDEWEB)

    Na, Gyeong Gyun; Lee, Mi Sook; Kim, Hee Jun; Sun, In O [Presbyterian Medical Center, Jeonju (Korea, Republic of)

    2016-01-15

    To describe the chest radiographic findings of acute paraquat poisoning. 691 patients visited the emergency department of our hospital between January 2006 and October 2012 for paraquat poisoning. Of these 691, we identified 56 patients whose initial chest radiographs were normal but who developed radiographic abnormalities within one week. We evaluated their radiographic findings and the differences in imaging features based on mortality. The most common finding was diffuse consolidation (29/56, 52%), followed by consolidation with linear and nodular opacities (18/56, 32%), and combined consolidation and pneumomediastinum (7/56, 13%). Pleural effusion was noted in 17 patients (30%). The two survivors (4%) showed peripheral consolidations, while the 54 patients (96%) who died demonstrated bilateral (42/54, 78%) or unilateral (12/54, 22%) diffuse consolidations. Rapidly progressing diffuse pulmonary consolidation was observed within one week on follow-up radiographs after paraquat ingestion in the deceased, but the survivors demonstrated peripheral consolidation.

  1. Radiographic findings of femoroacetabular impingement in National Football League Combine athletes undergoing radiographs for previous hip or groin pain.

    Science.gov (United States)

    Nepple, Jeffrey J; Brophy, Robert H; Matava, Matthew J; Wright, Rick W; Clohisy, John C

    2012-10-01

    The purpose of this study was to investigate the prevalence of radiographic findings of femoroacetabular impingement (FAI) in elite football players with a history of hip pain or groin injury who underwent radiographs. We performed a retrospective review of athletes undergoing hip radiography at the National Football League Combine from 2007 to 2009. Radiographs were obtained in athletes with a history of hip pain or injury. Anteroposterior pelvis and frog-lateral radiographs were obtained in 123 hips (107 players) that met our inclusion criteria. Radiographic indicators of cam-type FAI (alpha angle, head-neck offset ratio) and pincer-type FAI (acetabular retroversion, center-edge angle, acetabular inclination) were recorded. Findings were correlated with clinical factors (previous groin/hip pain, position, race, and body mass index). The most common previous injuries included groin strain (n = 57) and sports hernia/abdominal strain (n = 21). Markers of cam- and/or pincer-type FAI were present in 94.3% of hips (116 of 123). Radiographic evidence of combined cam- and pincer-type FAI was the most common (61.8%, 76 hips), whereas isolated cam-type FAI (9.8%, 12 hips) and pincer-type FAI (22.8%, 28 hips) were less common. The most common deformities included acetabular retroversion (71.5%) and an abnormal alpha angle (61.8%). A body mass index greater than 35 was associated with the presence of global overcoverage (46.2% v 17.3%, P = .025). Radiographic indicators of FAI are very common among athletes evaluated at the National Football League Scouting Combine subjected to radiographic examination for the clinical suspicion of hip disease. Elite football athletes with significant or recurrent pain about the hip should be evaluated clinically and radiographically for FAI, because pain from FAI may be falsely attributed to or may be present in addition to other disorders. Level IV, therapeutic case series. Copyright © 2012 Arthroscopy Association of North America

  2. Improvement in Detection of Wrong-Patient Errors When Radiologists Include Patient Photographs in Their Interpretation of Portable Chest Radiographs.

    Science.gov (United States)

    Tridandapani, Srini; Olsen, Kevin; Bhatti, Pamela

    2015-12-01

    This study was conducted to determine whether facial photographs obtained simultaneously with radiographs improve radiologists' detection rate of wrong-patient errors, when they are explicitly asked to include the photographs in their evaluation. Radiograph-photograph combinations were obtained from 28 patients at the time of portable chest radiography imaging. From these, pairs of radiographs were generated. Each unique pair consisted of one new and one old (comparison) radiograph. Twelve pairs of mismatched radiographs (i.e., pairs containing radiographs of different patients) were also generated. In phase 1 of the study, 5 blinded radiologist observers were asked to interpret 20 pairs of radiographs without the photographs. In phase 2, each radiologist interpreted another 20 pairs of radiographs with the photographs. Radiologist observers were not instructed about the purpose of the photographs but were asked to include the photographs in their review. The detection rate of mismatched errors was recorded along with the interpretation time for each session for each observer. The two-tailed Fisher exact test was used to evaluate differences in mismatch detection rates between the two phases. A p value of error detection rates without (0/20 = 0%) and with (17/18 = 94.4%) photographs were different (p = 0.0001). The average interpretation times for the set of 20 radiographs were 26.45 (SD 8.69) and 20.55 (SD 3.40) min, for phase 1 and phase 2, respectively (two-tailed Student t test, p = 0.1911). When radiologists include simultaneously obtained photographs in their review of portable chest radiographs, there is a significant improvement in the detection of labeling errors. No statistically significant difference in interpretation time was observed. This may lead to improved patient safety without affecting radiologists' throughput.

  3. A radiographic analysis of implant component misfit.

    LENUS (Irish Health Repository)

    Sharkey, Seamus

    2011-07-01

    Radiographs are commonly used to assess the fit of implant components, but there is no clear agreement on the amount of misfit that can be detected by this method. This study investigated the effect of gap size and the relative angle at which a radiograph was taken on the detection of component misfit. Different types of implant connections (internal or external) and radiographic modalities (film or digital) were assessed.

  4. The use and abuse of radiographic grids

    International Nuclear Information System (INIS)

    Brough, P.D.

    1981-01-01

    It is generally accepted that scattered radiation degrades the quality of the radiographic image. When this problem occurs, a radiographic grid may be applied which necessitates an increase in exposure. Investigations are reported in the following areas: reasons for the introduction of a radiographic grid; the ratio between kilovoltage and grid ratio; techniques resulting in higher contrast and resolution at low patient dose and the abuse of grids

  5. 21 CFR 892.1970 - Radiographic ECG/respirator synchronizer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic ECG/respirator synchronizer. 892.1970... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1970 Radiographic ECG/respirator synchronizer. (a) Identification. A radiographic ECG/respirator synchronizer is a device intended to be used to...

  6. Mark III LOCA-related hydrodynamic load definition. Generic technical activity B-10

    International Nuclear Information System (INIS)

    1984-02-01

    This report, prepared by the staff of the Office of Nuclear Reactor Regulation and its consultants at the Brookhaven National Laboratory, provides a discussion of LOCA-related suppression pool hydrodynamic loads in boiling water reactor (BWR) facilities with the Mark III pressure-suppression containment design. Its issuance completes NRC Generic Technical Activity B-10, Behavior of BWR Mark III Containment. On the basis of certain large-scale tests conducted between 1973 and 1979, the General Electric Company developed LOCA-related hydrodynamic load definitions for use in the design of the standard Mark III containment. The staff and its consultants have reviewed these load definitions and their bases conclude that, with a few specified changes, the proposed load definitions provide conservative loading conditions. The staff-approved acceptance criteria for LOCA-related hydrodynamic loads are provided in Appendix C of this report

  7. Brazilian young dental practitioners' use and acceptance of digital radiographic examinations

    Energy Technology Data Exchange (ETDEWEB)

    Rovaris, Karla; De Faria Vasconcelos, Karla; Do Nascimento, Eduarda Helena Leandro; Oliveira, Matheus Lima; Freitas, Deborah Queiroz; Haiter-Neto, Francisco [Div. of Oral Radiology, Dept. of Oral Diagnosis, Piracicaba Dental School, University of Campinas (UNICAMP), Sao Paulo (Brazil)

    2016-12-15

    The aim of this study was to investigate the use and acceptance of digital radiographic examinations by Brazilian dental practitioners in daily practice and to evaluate the advances that have occurred over the past 5 years. Dental practitioners enrolled in extension courses at the Piracicaba Dental School, University of Campinas, Brazil, responded to a self-administered questionnaire in the years 2011 and 2015. They were asked about sociodemographic factors and their knowledge and use of digital radiographic examinations. Descriptive analysis was performed, as well as the chi-square and Fisher exact tests, with a significance level of 5% (α=0.05). A total of 181 participants responded to the questionnaire in the years 2011 and 2015. Most of the respondents worked in private practice, had graduated within the last 5 years, and were between 20 and 30 years old. In 2011, 55.6% of respondents reported having ever used digital radiographic examinations, while in 2015 this number increased significantly to 85.4% (p<.0001), out of which 71.4% preferred it to conventional images. Moreover, 21.4% of respondents reported having used digital radiographic examinations for more than 3 years. A significant increase in use of intraoral digital radiography (p=0.0316) was observed in 2015. In both years, image quality and high cost were indicated, respectively, as the main advantage and disadvantage of digital radiographic examinations. This study showed that digital radiology has become more common in Brazil over the past 5 years. Most of the Brazilian dental practitioners evaluated in 2015 used digital radiographic examinations.

  8. European radiographers' challenges from mammography education and clinical practice - an integrative review.

    Science.gov (United States)

    Metsälä, Eija; Richli Meystre, Nicole; Pires Jorge, José; Henner, Anja; Kukkes, Tiina; Sá Dos Reis, Cláudia

    2017-06-01

    This study aims to identify European radiographers' challenges in clinical performance in mammography and the main areas of mammography that require more and better training. An extensive search was performed to identify relevant studies focused on clinical practice, education and training in mammography published between January 2010 and December 2015 in the English language. The data were analysed by using deductive thematic analysis. A total of 27 full text articles were read, evaluating their quality. Sixteen articles out of 27 were finally selected for this integrative review. The main challenges of radiographers' mammography education/training can be divided into three groups: training needs, challenges related to radiographers, and challenges related to the organization of education. The most common challenges of clinical performance in mammography among European radiographers involved technical performance, the quality of practices, and patient-centeredness. The introduction of harmonized mammography guidelines across Europe may serve as an evidence-based tool to be implemented in practice and education. However, the variability in human and material resources as well as the different cultural contexts should be considered during this process. • Radiographers' awareness of their professional identity and enhancing multiprofessional cooperation in mammography. • Radiographers' responsibilities regarding image quality (IQ) and optimal breast imaging performance. • Patient-centred mammography services focusing on the psychosocial needs of the patient. • Challenges: positioning, QC-testing, IQ-assessment, optimization of breast compression, communication, teamwork, and patient-centred care. • Introduction of evidence-based guidelines in Europe to harmonize mammography practice and education.

  9. Reliability of the craniocervical posture assessment: visual and angular measurements using photographs and radiographs.

    Science.gov (United States)

    Gadotti, Inae C; Armijo-Olivo, Susan; Silveira, Anelise; Magee, David

    2013-01-01

    The purposes of this study were to determine the intrarater and interrater reliability of the craniocervical posture in a sagittal view using quantitative measurements on photographs and radiographs and to determine the agreement of the visual assessment of posture between raters. One photograph and 1 radiograph of the sagittal craniocervical posture were simultaneously taken from 39 healthy female subjects. Three angles were measured on the photographs and 10 angles on the radiographs of 22 subjects using Alcimage software (Alcimage; Uberlândia, MG, Brazil). Two repeated measurements were performed by 2 raters. The measurements were compared within and between raters to test the intrarater and interrater reliability, respectively. Intraclass correlation coefficient and SEM were used. κ Agreement was calculated for the visual assessment of 39 subjects using photographs and radiographs between 2 raters. Good to excellent intrarater and interrater intraclass correlation coefficient values were found on both photographs and radiographs. Interrater SEM was large and clinically significant for cervical lordosis photogrammetry and for 1 angle measuring cervical lordosis on radiographs. Interrater κ agreement for the visual assessment using photographs was poor (κ = 0.37). The raters were reliable to measure angles in photographs and radiographs to quantify craniocervical posture with exception of 2 angles measuring lordosis of the cervical spine when compared between raters. The visual assessment of posture between raters was not reliable. © 2013. Published by National University of Health Sciences All rights reserved.

  10. Complications from radiographer-performed double contrast barium enemas

    Energy Technology Data Exchange (ETDEWEB)

    Vora, P.; Chapman, A. E-mail: anthony.chapman@leedsth.nhs.uk

    2004-04-01

    AIM: To determine the types and rates of complications encountered by radiographers when performing double contrast barium enemas (DCBE). MATERIALS AND METHODS: Seven hundred and forty-one questionnaires were posted to radiographers who had in the last 5 years attended one of the biannual barium enema training courses. RESULTS: Of 741 questionnaires posted 407 (54.9%) were returned completed. Approximately 348,000 barium enema examinations had been performed. Fifty-nine radiographers reported 89 complications, including 13 intra-peritoneal and 11 extra-peritoneal perforations. There were five deaths (mortality 1 in 70,000). Deaths resulted from two of 24 (10%) perforations, two of 45 (5%) cardiac events and one cerebrovascular accident that occurred during an examination. CONCLUSIONS: Radiographers have been regularly performing DCBEs for almost a decade. The mortality for radiographer-performed DCBE is similar to that previously reported for radiologists, although a slightly higher rate of perforation is noted and so this is an area where radiographer training should be targeted.

  11. Complications from radiographer-performed double contrast barium enemas

    International Nuclear Information System (INIS)

    Vora, P.; Chapman, A.

    2004-01-01

    AIM: To determine the types and rates of complications encountered by radiographers when performing double contrast barium enemas (DCBE). MATERIALS AND METHODS: Seven hundred and forty-one questionnaires were posted to radiographers who had in the last 5 years attended one of the biannual barium enema training courses. RESULTS: Of 741 questionnaires posted 407 (54.9%) were returned completed. Approximately 348,000 barium enema examinations had been performed. Fifty-nine radiographers reported 89 complications, including 13 intra-peritoneal and 11 extra-peritoneal perforations. There were five deaths (mortality 1 in 70,000). Deaths resulted from two of 24 (10%) perforations, two of 45 (5%) cardiac events and one cerebrovascular accident that occurred during an examination. CONCLUSIONS: Radiographers have been regularly performing DCBEs for almost a decade. The mortality for radiographer-performed DCBE is similar to that previously reported for radiologists, although a slightly higher rate of perforation is noted and so this is an area where radiographer training should be targeted

  12. On higher order and anisotropic hydrodynamics for Bjorken and Gubser flows

    CERN Document Server

    2018-01-01

    We study the evolution of hydrodynamic and non-hydrodynamic moments of the distribution function using anisotropic and third-order Chapman-Enskog hydrodynamics for systems undergoing Bjorken and Gubser flows. The hydrodynamic results are compared with the exact solution of the Boltzmann equation with a collision term in relaxation time approximation. While the evolution of the hydrodynamic moments of the distribution function (i.e. of the energy momentum tensor) can be described with high accuracy by both hydrodynamic approximation schemes, their description of the evolution of the entropy of the system is much less precise. We attribute this to large contributions from non-hydrodynamic modes coupling into the entropy evolution which are not well captured by the hydrodynamic approximations. The differences between the exact solution and the hydrodynamic approximations are larger for the third-order Chapman-Enskog hydrodynamics than for anisotropic hydrodynamics, which effectively resums some of the dissipati...

  13. Hydrodynamic analysis and simulation of a flow cell ammonia electrolyzer

    International Nuclear Information System (INIS)

    Diaz, Luis A.; Botte, Gerardine G.

    2015-01-01

    Highlights: • NH_3 electrooxidation mechanism was validated in a bench scale electrolyzer. • All kinetic parameters for NH_3 electro-oxidation were calculated and verified. • Hydrodynamic behavior of the NH_3 electrolyzer was properly described as a CSTR. • CSTR model was successfully applied to simulate a flow ammonia electrolyzer. - Abstract: The hydrodynamic analysis and simulation of a non-ideal single pass flow cell alkaline ammonia electrolyzer was performed after the scale-up of a well-characterized deposited polycrystalline Pt on Ni anode. The hydrodynamic analysis was performed using the residence time distribution (RTD) test. The results of the hydrodynamic investigation provide additional insights for the kinetic analysis of the ammonia electrooxidation reaction on polycrystalline Pt electrocatalysts -which are typically obtained under controlled flow regime, e.g., rotating disk electrode- by including the flow non-uniformity present in the electrolyzer. Based on the RTD function, the ammonia electrolyzer performance was simulated as a non-steady stirred tank reactor (CSTR) and the unknown kinetic parameters were obtained by fitting the simulation results with an experimental current profile, obtaining an adequate prediction of the ammonia conversion. This simplified approach for the simulation of the ammonia electrolyzer could be implemented in process simulation packages and could be used for the design and scale-up of the process for hydrogen production and wastewater remediation.

  14. Effect of display type and room illuminance in chest radiographs

    International Nuclear Information System (INIS)

    Liukkonen, Esa; Jartti, Airi; Haapea, Marianne; Oikarinen, Heljae; Ahvenjaervi, Lauri; Mattila, Seija; Nevala, Terhi; Palosaari, Kari; Perhomaa, Marja; Nieminen, Miika T.

    2016-01-01

    To compare diagnostic accuracy in the detection of subtle chest lesions on digital chest radiographs using medical-grade displays, consumer-grade displays, and tablet devices under bright and dim ambient light. Five experienced radiologists independently assessed 50 chest radiographs (32 with subtle pulmonary findings and 18 without apparent findings) under bright (510 lx) and dim (16 lx) ambient lighting. Computed tomography was used as the reference standard for interstitial and nodular lesions and follow-up chest radiograph for pneumothorax. Diagnostic accuracy and sensitivity were calculated for assessments carried out in all displays and compared using the McNemar test. The level of significance was set to p < 0.05. Significant differences in sensitivity between the assessments under bright and dim lighting were found among consumer-grade displays in interstitial opacities with, and in pneumothorax without, Digital Imaging and Communication in Medicine-Grayscale Standard Display Function (DICOM-GSDF) calibration. Compared to 6 megapixel (MP) display under bright lighting, sensitivity in pneumothorax was lower in the tablet device and the consumer-grade display. Sensitivity in interstitial opacities was lower in the DICOM-GSDF calibrated consumer-grade display. A consumer-grade display with or without DICOM-GSDF calibration or a tablet device is not suitable for reading digital chest radiographs in bright lighting. No significant differences were observed between five displays in dim light. (orig.)

  15. Radiographic manifestations of arthritis in AIDS patients

    International Nuclear Information System (INIS)

    Rosenberg, Z.S.; Norman, A.; Solomon, G.

    1988-01-01

    The purpose of this study is to familiarize the radiologist with a newly discovered association between arthritis and acquired immunodeficiency syndrome (AIDS). The authors retrospectively reviewed the clinical and radiographic findings in 31 patients with human immunodeficiency virus (HIV) infection referred to their rheumatology clinic with musculoskeletal complaints. The patients carried a wide range of clinical diagnosis including Reiter syndrome, psoriatic arthritis, undifferentiated seronegative arthritis, isolated enthesopathies, rheumatoid arthritis and osteonecrosis. Radiographs were available in 24 of the 31 patients, and in 20 they showed radiographic features of arthritis, which included soft-tissue swelling periarticular osteoporosis, synovial effusions, sacroiliitis, periosteal reaction, joint space narrowing, marginal erosions, and osteonecrosis. Although the radiographic abnormalities were frequently mild, they were significant, given the short duration of disease in many of their patients (weeks to months) at the time radiographs were obtained. The range of radiographic findings in their series was varied and paralleled the wide range of clinical diagnoses. No findings were pathognomonic for HIV-associated arthritis. Nevertheless, HIV infection needs to be considered in any patient belonging to a recognized risk group who presents with musculoskeletal disease. This is particularly important since immunosupressive drugs used for the treatment of arthritis can be detrimental to patients with HIV infection

  16. Radiographer emergency department hot reporting: An assessment of service quality and feasibility

    Energy Technology Data Exchange (ETDEWEB)

    Hardy, Maryann [Division of Radiography, School of Health Studies, University of Bradford, Trinity Road, Bradford, West Yorkshire BD5 0BB (United Kingdom)], E-mail: m.l.hardy1@bradford.ac.uk; Spencer, Nicholas; Snaith, Beverly [Mid Yorkshire Hospitals NHS Trust, Radiology Department, Pinderfields General Hospital, Aberford Road, Wakefield WF1 4DG (United Kingdom)

    2008-11-15

    Purpose: Radiographer reporting has been implemented widely as cold reporting. This study aimed to compare hot and cold reports by the same radiographer to establish whether there was any significant difference in the diagnostic outcome. Method: Three experienced radiographers reported 1618 musculoskeletal trauma cases over a 3 month period. These cases were stratified for age (0-17 years; 18-50 years; 51 years+) and a random sample of 400 cases selected (95% confidence interval, 90% power) for delayed reporting. Both reports were independently compared by 2 experienced film readers. Results: Radiographs and notes on 391 (97.8%; n = 391/400) cases were located (age range 3 months to 97 years) for cold reporting. The diagnostic outcome of the reports was concordant in 357 cases (91.3%; n = 357/391) and discrepant in 34 cases (8.7%; n = 34/391). Logistic regression performed on age stratified discrepancies indicated that paediatric cases had increased odds of receiving discrepant reports (OR = 3.34; p = 0.005; 95% CI [1.44-7.74]). Hot and cold report agreement was high ({kappa} = 0.87). McNemar's test demonstrated no significant difference in the report discrepancies (p = 0.189). Conclusion: No significant difference was demonstrated between the diagnostic outcome of radiographer hot reports, issued whilst working within the trauma radiography department at time of patient attendance, and cold reports.

  17. Radiographer emergency department hot reporting: An assessment of service quality and feasibility

    International Nuclear Information System (INIS)

    Hardy, Maryann; Spencer, Nicholas; Snaith, Beverly

    2008-01-01

    Purpose: Radiographer reporting has been implemented widely as cold reporting. This study aimed to compare hot and cold reports by the same radiographer to establish whether there was any significant difference in the diagnostic outcome. Method: Three experienced radiographers reported 1618 musculoskeletal trauma cases over a 3 month period. These cases were stratified for age (0-17 years; 18-50 years; 51 years+) and a random sample of 400 cases selected (95% confidence interval, 90% power) for delayed reporting. Both reports were independently compared by 2 experienced film readers. Results: Radiographs and notes on 391 (97.8%; n = 391/400) cases were located (age range 3 months to 97 years) for cold reporting. The diagnostic outcome of the reports was concordant in 357 cases (91.3%; n = 357/391) and discrepant in 34 cases (8.7%; n = 34/391). Logistic regression performed on age stratified discrepancies indicated that paediatric cases had increased odds of receiving discrepant reports (OR = 3.34; p = 0.005; 95% CI [1.44-7.74]). Hot and cold report agreement was high (κ = 0.87). McNemar's test demonstrated no significant difference in the report discrepancies (p = 0.189). Conclusion: No significant difference was demonstrated between the diagnostic outcome of radiographer hot reports, issued whilst working within the trauma radiography department at time of patient attendance, and cold reports

  18. Radiographers' preconditions for evidence-based radiography

    International Nuclear Information System (INIS)

    Ahonen, Sanna-Mari; Liikanen, Eeva

    2010-01-01

    Evidence-based practice (EBP) is essential in today's health care, but its establishment requires several preconditions from individuals and organizations (e.g. knowledge, understanding, attitudes, abilities, self-confidence, support, and resources). Previous studies suggest that radiographers do generate and use evidence in their work, but evidence-based radiography (EBR) is not yet used routinely as established practice, especially in terms of research utilization. This paper aims to describe radiographers' preconditions for EBR, and their participation in research activities. Main focus is on research utilization. Using an electronic questionnaire developed for this study, a survey was conducted: data collected from Finnish radiographers and radiotherapists (N = 438) were analysed both statistically and qualitatively. The final response rate was 39%. The results suggest radiographers' preconditions for EBR to consist of knowledge of research, significance of research activities, research-orientated way of working, and support. In addition, adequate resourcing is essential. Reading scientific journals, participation in research activities, a higher degree of education, and senior post seem to be significant promoters of EBR and research utilization. The results support the notion that EBR, and especially research utilization, are not yet well-established in Finland, and radiographers' viewpoints concerning the role and significance of research evidence and research activities still seem to vary.

  19. Radiographic evaluation of the diabetic foot

    International Nuclear Information System (INIS)

    Jacobs, A.M.

    1989-01-01

    Radiographic evaluation of the foot in the patient with diabetes mellitus is discussed in this paper. According to the author, it can only be of value when the soft tissue and bony and joint pathologic conditions, which occur more frequently in the diabetic patient are also considered and understood. Although not pathognomic for diabetes mellitus, neuroarthopathy, osteomyelitis, soft tissue infection, and some rheumatic disorders are present with greater frequency in diabetic populations than in non-diabetic populations. Frequently, edema, erythema, hyperthermia, and tenderness are present as nonspecific clinical findings, in which case radiographic evaluation is called upon to define the specific etiology of a particular patient's pathology. Unfortunately, many radiographic, computerized tomographic, and radionuclide studies demonstrate less than optimal positive and negative predictive values unless interpreted in view of clinical history and examination and integrated with the results of other laboratory data. Radiographic evaluation of the diabetic foot may be utilized to establish the presence of disease, the extent of pedal involvement, and the response to therapy. The establishment of the nature of disease processes from radiographic findings alone, however, may be problematic. The diagnosis of osteomyelitis, for example, rests on the recovery of the offending microorganisms from bone aspiration or culture

  20. A Computational Study on Hydrodynamic Torque Coefficients of a Butterfly Valve

    International Nuclear Information System (INIS)

    Lee, Do-Hwan; Park, Sung-Keun; Kang, Shin-Chul; Kim, Dae-Woong; Park, Ju-Yeop

    2007-01-01

    Butterfly valves have been widely used for on-off or control purposes in the process industry, since they provide quick opening and closing operation and good flow control characteristics. For the evaluation of the adequacy of valve operability and the actuator sizing, the required torque estimation is necessary. Since the principal contributing component of the require torque in the mid-stroke position is hydrodynamic torque, it is necessary to predict the torque properly under the actual flow conditions. The research on the prediction of the valve performance was led by EPRI (Electric Power Research Institute) in early 1990s. A performance prediction model was developed based on the experimental results and the free-streamline analysis by Sarpkaya. Recently, Kalsi Engineering carried out extended tests and developed the improved model. Variation of disk geometries and upstream flow conditions were tried to obtain accurate hydrodynamic torque coefficients. However, since the model is only commercially available, a general method to obtain hydrodynamic torque for butterfly valves is called for

  1. Hydrodynamic Lubrication

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 1; Issue 9. Hydrodynamic Lubrication Experiment with 'Floating' Drops. Jaywant H Arakeri K R Sreenivas. General Article Volume 1 Issue 9 September 1996 pp 51-58. Fulltext. Click here to view fulltext PDF. Permanent link:

  2. Hydrodynamic interactions in active colloidal crystal microrheology

    OpenAIRE

    Weeber, R; Harting, JDR Jens

    2012-01-01

    In dense colloids it is commonly assumed that hydrodynamic interactions do not play a role. However, a found theoretical quantification is often missing. We present computer simulations that are motivated by experiments where a large colloidal particle is dragged through a colloidal crystal. To qualify the influence of long-ranged hydrodynamics, we model the setup by conventional Langevin dynamics simulations and by an improved scheme with limited hydrodynamic interactions. This scheme signif...

  3. Radiographic features of periapical cysts and granulomas

    OpenAIRE

    Zain, R. B.; Roswati, N.; Ismail, K.

    1989-01-01

    Many studies have been reported on radiographic lesion sizes of periapical lesions. However no studies have been reported on prevalences of subjective radiographic features in these lesions except for the early assumption that a periapical cyst usually exhibit a radiopaque cortex. This study is conducted to evaluate the prevalences of several subjective radiographic features of periapical cysts and granulomas in the hope to identify features that maybe suggestive of either diagnosis. The resu...

  4. Comparison of film/screen and PCR digital lateral cervical spine radiographs

    International Nuclear Information System (INIS)

    Silver, D.I.; Kreipke, D.L.; Tarver, R.; Braunstein, E.M.

    1988-01-01

    The authors compared film/screen and Phillips computed radiography (PCR) radiographs of the cervical spine. In 109 patients. fiilm/screen and digital radiographs were compared for adequate visualization (readability) of bone, soft tissue, and trachea. The lowest cervical vertebra seen was noted in each case. The radiographs were interpreted by four radiologists, and both interobserver and intraobserver consistency were measured. Of the PCR radiographs, 97% were readable with a viewbox alone. Of the film/screen radiographs, 9% were readable with a viewbox. With a hotlight, 83% of the film/screen radiographs became readable. Bone, soft tissue, and trachea were better seen on PCR radiographs than on film/screen radiographs (P<.001). There was less interobserver variation on digital radiographs. Readability of cervical spine radiographs was significantly improved with PCR

  5. Biometric Analysis – A Reliable Indicator for Diagnosing Taurodontism using Panoramic Radiographs

    Science.gov (United States)

    Hegde, Veda; Anegundi, Rajesh Trayambhak; Pravinchandra, K.R.

    2013-01-01

    Background: Taurodontism is a clinical entity with a morpho–anatomical change in the shape of the tooth, which was thought to be absent in modern man. Taurodontism is mostly observed as an isolated trait or a component of a syndrome. Various techniques have been devised to diagnose taurodontism. Aim: The aim of this study was to analyze whether a biometric analysis was useful in diagnosing taurodontism, in radiographs which appeared to be normal on cursory observations. Setting and Design: This study was carried out in our institution by using radiographs which were taken for routine procedures. Material and Methods: In this retrospective study, panoramic radiographs were obtained from dental records of children who were aged between 9–14 years, who did not have any abnormality on cursory observations. Biometric analyses were carried out on permanent mandibular first molar(s) by using a novel biometric method. The values were tabulated and analysed. Statistics: Fischer exact probability test, Chi square test and Chi-square test with Yates correction were used for statistical analysis of the data. Results: Cursory observation did not yield us any case of taurodontism. In contrast, the biometric analysis yielded us a statistically significant number of cases of taurodontism. However, there was no statistically significant difference in the number of cases with taurodontism, which was obtained between the genders and the age group which was considered. Conclusion: Thus, taurodontism was diagnosed on a biometric analysis, which was otherwise missed on a cursory observation. It is therefore necessary from the clinical point of view, to diagnose even the mildest form of taurodontism by using metric analysis rather than just relying on a visual radiographic assessment, as its occurrence has many clinical implications and a diagnostic importance. PMID:24086912

  6. Radiographic identification of the equine ventral conchal bulla.

    Science.gov (United States)

    Finnegan, C M; Townsend, N B; Barnett, T P; Barakzai, S Z

    Involvement of the ventral conchal sinus (VCS) is an important diagnostic and prognostic feature in cases of the equine sinus disease. The authors aimed to ascertain if the caudo-dorsal extension of the VCS, the ventral conchal bulla (VCB) is identifiable on plain radiographs of cadaver skulls without sinus disease. Bilateral frontonasal sinus flaps were made in 10 equine cadaver skulls. Plain lateral, lateral oblique and dorso-ventral radiographs were then obtained followed by the same views taken with stainless steel wire outlining the caudal border of the VCB. Plain radiographs were randomised and blindly evaluated by two observers who marked where they believed the VCB to be positioned. This was then correlated with the true position of the VCB using radiographs with wires in place. The ease of identification of the VCB was classified as 'easy' or 'difficult'. The VCB was correctly identified in 70 per cent of lateral radiographs, but only 45 per cent of lateral oblique radiographs and 17 per cent of dorso-ventral radiographs. If a clinician was confident that he or she could identify the VCB, they were usually correct. Conversely if the clinician judged VCB identification as 'difficult', they usually identified it incorrectly. In the authors' clinical experience, the VCB of horses with sinusitis involving this compartment is more radiologically evident than in clinically normal horses. Knowledge of the normal radiographic anatomy of this structure should aid clinicians in identifying horses with sinusitis affecting the VCS.

  7. Contribution to identification of factors causing radiographic image unsharpness

    International Nuclear Information System (INIS)

    Branzan, C.; Popescu, A.; Radu, R.

    1995-01-01

    Radiographic image quality is crucial for the ability of the radiographic method to give us a maximum information about the macroscopic structure of materials and pieces, investigated by penetrating radiation. Radiographic image quality depends on several factors. A high quality image is able to show small and typical defects. One of the most important factor affecting radiographic image is unsharpness. The total effective unsharpness of the film must be some function of several factors and their contribution is taken into account by summing up different kinds of unsharpness: geometric unsharpness, internal unsharpness, screen unsharpness, and accidental unsharpness. This work analyses the weight of the radiographic image unsharpness and the possibilities for determining its influence on the quality of the radiographic image. (author)

  8. Universal hydrodynamics of non-conformal branes

    International Nuclear Information System (INIS)

    Kanitscheider, Ingmar; Skenderis, Kostas

    2009-01-01

    We examine the hydrodynamic limit of non-conformal branes using the recently developed precise holographic dictionary. We first streamline the discussion of holography for backgrounds that asymptote locally to non-conformal brane solutions by showing that all such solutions can be obtained from higher dimensional asymptotically locally AdS solutions by suitable dimensional reduction and continuation in the dimension. As a consequence, many holographic results for such backgrounds follow from the corresponding results of the Asymptotically AdS case. In particular, the hydrodynamics of non-conformal branes is fully determined in terms of conformal hydrodynamics. Using previous results on the latter we predict the form of the non-conformal hydrodynamic stress tensor to second order in derivatives. Furthermore we show that the ratio between bulk and shear viscosity is fixed by the generalized conformal structure to be ζ/η = 2(1/(d-1)-c s 2 ), where c s is the speed of sound in the fluid.

  9. Global SWOT Data Assimilation of River Hydrodynamic Model; the Twin Simulation Test of CaMa-Flood

    Science.gov (United States)

    Ikeshima, D.; Yamazaki, D.; Kanae, S.

    2016-12-01

    CaMa-Flood is a global scale model for simulating hydrodynamics in large scale rivers. It can simulate river hydrodynamics such as river discharge, flooded area, water depth and so on by inputting water runoff derived from land surface model. Recently many improvements at parameters or terrestrial data are under process to enhance the reproducibility of true natural phenomena. However, there are still some errors between nature and simulated result due to uncertainties in each model. SWOT (Surface water and Ocean Topography) is a satellite, which is going to be launched in 2021, can measure open water surface elevation. SWOT observed data can be used to calibrate hydrodynamics model at river flow forecasting and is expected to improve model's accuracy. Combining observation data into model to calibrate is called data assimilation. In this research, we developed data-assimilated river flow simulation system in global scale, using CaMa-Flood as river hydrodynamics model and simulated SWOT as observation data. Generally at data assimilation, calibrating "model value" with "observation value" makes "assimilated value". However, the observed data of SWOT satellite will not be available until its launch in 2021. Instead, we simulated the SWOT observed data using CaMa-Flood. Putting "pure input" into CaMa-Flood produce "true water storage". Extracting actual daily swath of SWOT from "true water storage" made simulated observation. For "model value", we made "disturbed water storage" by putting "noise disturbed input" to CaMa-Flood. Since both "model value" and "observation value" are made by same model, we named this twin simulation. At twin simulation, simulated observation of "true water storage" is combined with "disturbed water storage" to make "assimilated value". As the data assimilation method, we used ensemble Kalman filter. If "assimilated value" is closer to "true water storage" than "disturbed water storage", the data assimilation can be marked effective. Also

  10. Development and Assessment of an E-Learning Course on Breast Imaging for Radiographers: A Stratified Randomized Controlled Trial

    Science.gov (United States)

    Ventura, Sandra Rua; Ramos, Isabel; Rodrigues, Pedro Pereira

    2015-01-01

    Background Mammography is considered the best imaging technique for breast cancer screening, and the radiographer plays an important role in its performance. Therefore, continuing education is critical to improving the performance of these professionals and thus providing better health care services. Objective Our goal was to develop an e-learning course on breast imaging for radiographers, assessing its efficacy, effectiveness, and user satisfaction. Methods A stratified randomized controlled trial was performed with radiographers and radiology students who already had mammography training, using pre- and post-knowledge tests, and satisfaction questionnaires. The primary outcome was the improvement in test results (percentage of correct answers), using intention-to-treat and per-protocol analysis. Results A total of 54 participants were assigned to the intervention (20 students plus 34 radiographers) with 53 controls (19+34). The intervention was completed by 40 participants (11+29), with 4 (2+2) discontinued interventions, and 10 (7+3) lost to follow-up. Differences in the primary outcome were found between intervention and control: 21 versus 4 percentage points (pp), Pe-learning course is effective, especially for radiographers, which highlights the need for continuing education. PMID:25560547

  11. Frequency-dependent hydrodynamic interaction between two solid spheres

    Science.gov (United States)

    Jung, Gerhard; Schmid, Friederike

    2017-12-01

    Hydrodynamic interactions play an important role in many areas of soft matter science. In simulations with implicit solvent, various techniques such as Brownian or Stokesian dynamics explicitly include hydrodynamic interactions a posteriori by using hydrodynamic diffusion tensors derived from the Stokes equation. However, this equation assumes the interaction to be instantaneous which is an idealized approximation and only valid on long time scales. In the present paper, we go one step further and analyze the time-dependence of hydrodynamic interactions between finite-sized particles in a compressible fluid on the basis of the linearized Navier-Stokes equation. The theoretical results show that at high frequencies, the compressibility of the fluid has a significant impact on the frequency-dependent pair interactions. The predictions of hydrodynamic theory are compared to molecular dynamics simulations of two nanocolloids in a Lennard-Jones fluid. For this system, we reconstruct memory functions by extending the inverse Volterra technique. The simulation data agree very well with the theory, therefore, the theory can be used to implement dynamically consistent hydrodynamic interactions in the increasingly popular field of non-Markovian modeling.

  12. Comparison of tentative radiographic working length with and without grid versus electronic apex locator

    Directory of Open Access Journals (Sweden)

    Tanikonda Rambabu

    2018-01-01

    Full Text Available The apical termination of obturation is the most important factor influencing the success of root canal treatment (RCT. Working length (WL is the key element in achieving this. Aim: The aim of this study is to compare and evaluate the preoperative estimated WL with conventional radiograph and with grid radiograph, with reference to electronic apex locator (EAL in single-rooted teeth. Settings and Design: Thirty permanent anterior teeth with complete root formation indicated for RCT were included in this study. Materials and Methods: Conventional radiograph (Group 1 and conventional radiograph with external grid (Group 2 were made before access opening. WL with EAL (Group 3 was determined after access opening. Statistical Analysis: The statistical package for the social sciences (SPSS version 16.0 (SPSS Inc., Chicago, IL, USA was used to compare the WLs of three groups, and the statistical significance was considered to be P ≤ 0.05. ANOVA, post hoc test were made to measure the intergroup comparison, and Pearson correlation values were obtained. Results and Conclusion: The results of the study showed a higher correlation between grid WL and apex locator WL than conventional WL and apex locator WL. Preoperative metrics with radiographic grid along with the apex locator is a better measuring tool compared to the conventional radiographic WL in a single-rooted tooth.

  13. Radiographic alterations of the frontal sinus morphology according to variations of the vertical angle in posteroanterior radiographs of the skull

    Directory of Open Access Journals (Sweden)

    Rhonan Ferreira Silva

    2014-03-01

    The frontal sinuses play a highly relevant role in comparative human identification processes. Since forensic radiology is a branch in the forensic sciences, adequate radiological analysis of the frontal sinuses is essential for comparative human identifications. The current study investigates radiographic morphological changes in the frontal sinuses according to vertical angle distortions in posteroanterior (PA radiographs. A standard PA radiograph of the skull of an adult was obtained. Eight addition PA radiographs were taken at different vertical angles. Frontal sinuses were analyzed qualitatively and quantitatively according to Ribeiro´s (2000 technique. Both qualitative and quantitative analyses revealed significant image distortions. Further, overlapping anatomical structures were reported when PA radiographs were analyzed in negative angulation distortions (from -10° to -40°. Positive and negative angular distortions up to 20º slightly affected the qualitative morphological analysis. However, 10° positive and negative distortions provided a significant interference in quantitative analysis and impaired the measuring process. Most forensic techniques for the analysis of frontal sinuses comprise measurements of morphological distances. Distortions of approximately 10° or over in vertical angulation of cranial PA radiographs should be avoided so that more accurate comparative human identifications could be achieved.

  14. A Novel Method to Determine the Hydrodynamic Coefficients of an Eyeball ROV

    Energy Technology Data Exchange (ETDEWEB)

    Yh, Eng; Ws, Lau; Low, E.; Ggl, Seet; Cs, Chin [Robotic Research Center, School of Mechanical & Aerospace Engineering (MAE), Nanyang Technological University, 50 Nanyang Ave, 639798 Singapore (Singapore)

    2009-01-12

    A good dynamics model is essential and critical for the successful design of navigation and control system of an underwater vehicle. However, it is difficult to determine from the hydrodynamic forces, the inertial added mass terms and the drag coefficients. In this paper, a new experimental method has been used to find the hydrodynamic forces for the ROV II, a remotely operated underwater vehicle. The proposed method is based on the classical free decay test, but with the spring oscillation replaced by a pendulum motion. The experiment results determined from the free decay test of a scaled model compared well with the simulation results obtained from well‐established computational fluid dynamics (CFD) program. Thus, the proposed approach can be used to find the added mass and drag coefficients for other underwater vehicles.

  15. A Novel Method to Determine the Hydrodynamic Coefficients of an Eyeball ROV

    International Nuclear Information System (INIS)

    Yh, Eng; Ws, Lau; Low, E.; Ggl, Seet; Cs, Chin

    2009-01-01

    A good dynamics model is essential and critical for the successful design of navigation and control system of an underwater vehicle. However, it is difficult to determine from the hydrodynamic forces, the inertial added mass terms and the drag coefficients. In this paper, a new experimental method has been used to find the hydrodynamic forces for the ROV II, a remotely operated underwater vehicle. The proposed method is based on the classical free decay test, but with the spring oscillation replaced by a pendulum motion. The experiment results determined from the free decay test of a scaled model compared well with the simulation results obtained from well‐established computational fluid dynamics (CFD) program. Thus, the proposed approach can be used to find the added mass and drag coefficients for other underwater vehicles.

  16. Hydrodynamics of insect spermatozoa

    Science.gov (United States)

    Pak, On Shun; Lauga, Eric

    2010-11-01

    Microorganism motility plays important roles in many biological processes including reproduction. Many microorganisms propel themselves by propagating traveling waves along their flagella. Depending on the species, propagation of planar waves (e.g. Ceratium) and helical waves (e.g. Trichomonas) were observed in eukaryotic flagellar motion, and hydrodynamic models for both were proposed in the past. However, the motility of insect spermatozoa remains largely unexplored. An interesting morphological feature of such cells, first observed in Tenebrio molitor and Bacillus rossius, is the double helical deformation pattern along the flagella, which is characterized by the presence of two superimposed helical flagellar waves (one with a large amplitude and low frequency, and the other with a small amplitude and high frequency). Here we present the first hydrodynamic investigation of the locomotion of insect spermatozoa. The swimming kinematics, trajectories and hydrodynamic efficiency of the swimmer are computed based on the prescribed double helical deformation pattern. We then compare our theoretical predictions with experimental measurements, and explore the dependence of the swimming performance on the geometric and dynamical parameters.

  17. Unicystic Jaw Lesions: A Radiographic Guideline

    Directory of Open Access Journals (Sweden)

    Giju George

    2010-01-01

    Full Text Available The unilocular radiolucencies remain the topic of much interest for the clinicians and histhopathologists for decades. Adequate use of diagnostic aids and careful observation will clinically help the dentist to arrive at a proper diagnosis and renders quality treatment to patients. Despite of the development of various cross-sectional imaging modalities, the radiograph still remains as the first and most important investigation. Jaw bone lesions, especially unilocular ones, are difficult to diagnose radiologically because of their similar radiographic appearance. It is, thus, very important for the clinician to have a sound knowledge of various radiographic features of the tooth and its supporting structures.

  18. Assessment of core thermo-hydrodynamic models of REFLA-1D with CCTF data

    International Nuclear Information System (INIS)

    Okubo, Tsutomu; Murao, Yoshio

    1983-07-01

    In order to assess the core thermo-hydrodynamic models of REFLA-1D/MODE3, which is the latest version of REFLA-1D, several calculations of the core thermo-hydrodynamics have been performed for the CCTF Core-I series tests. The measured initial and boundary conditions were used for these calculations. The calculational results showed that the water accumulation model of Case 2 could predict the CCTF results fairly well as it could for the JAERI small scale facility. The calculated results for the base case and the EM tests were in good agreement with the CCTF data. The parameter effects, such as system pressure, initial clad temperature, Acc injection rate, LPCI injection rate and initial down-comer wall temperature, were predicted correctly, except for the high system pressure and the high LPCI injection rate tests. (author)

  19. Adult Sail Sign: Radiographic and Computed Tomographic Features

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yu-Jin; Han, Daehee; Koh, Young Hwan; Zo, Joo Hee; Kim, Sang-Hyun; Kim, Deog Kyeom; Lee, Jeong Sang; Moon, Hyeon Jong; Kim, Jong Seung; Chun, Eun Ju; Youn, Byung Jae; Lee, Chang Hyun; Kim, Sam Soo (Dept. of Radiology, Cheil General Hospital, Kwandong Univ. College of Medicine, Seoul (KR))

    2008-02-15

    Background: The sail sign is a well-known radiographic feature of the pediatric chest. This sign can be observed in an adult population as well, but for a different reason. Purpose: To investigate the sail sign appearing in adult chest radiography. Material and Methods: Based on two anecdotal adult cases in which frontal chest radiographs showed the sail sign, we prospectively screened radiographs of 10,238 patients to determine the incidence of the sail sign found in adults in their 40s or older. The cause of the sail sign was assessed using computed tomography (CT). Results: The sail sign was revealed in 10 (seven males, three females; median age 60.6 years) of 10,238 patients. Of these 10 patients with a sail sign on frontal radiographs, eight underwent CT. The frontal radiographs of these 10 patients showed a concave superior margin toward the lung in nine patients, a concave inferior margin in five, and a double-lined inferior margin in three. Lateral radiographs disclosed a focal opacity over the minor fissure in five of six patients, which was either fuzzy (n = 4) or sharp (n = 1) in its upper margin, and was sometimes double lined in the inferior margin (n = 3). CT revealed the anterior mediastinal fat to be the cause of the radiographic sail sign, which stretched laterally from the mediastinum to insinuate into the minor fissure. Conclusion: The incidence of sail sign on adult chest radiographs is about 0.1%. The sign is specific enough to eliminate the need for more sophisticated imaging

  20. Adult Sail Sign: Radiographic and Computed Tomographic Features

    International Nuclear Information System (INIS)

    Lee, Yu-Jin; Han, Daehee; Koh, Young Hwan; Zo, Joo Hee; Kim, Sang-Hyun; Kim, Deog Kyeom; Lee, Jeong Sang; Moon, Hyeon Jong; Kim, Jong Seung; Chun, Eun Ju; Y oun, Byung Jae; Lee, Chang Hyun; Kim, Sam Soo

    2008-01-01

    Background: The sail sign is a well-known radiographic feature of the pediatric chest. This sign can be observed in an adult population as well, but for a different reason. Purpose: To investigate the sail sign appearing in adult chest radiography. Material and Methods: Based on two anecdotal adult cases in which frontal chest radiographs showed the sail sign, we prospectively screened radiographs of 10,238 patients to determine the incidence of the sail sign found in adults in their 40s or older. The cause of the sail sign was assessed using computed tomography (CT). Results: The sail sign was revealed in 10 (seven males, three females; median age 60.6 years) of 10,238 patients. Of these 10 patients with a sail sign on frontal radiographs, eight underwent CT. The frontal radiographs of these 10 patients showed a concave superior margin toward the lung in nine patients, a concave inferior margin in five, and a double-lined inferior margin in three. Lateral radiographs disclosed a focal opacity over the minor fissure in five of six patients, which was either fuzzy (n = 4) or sharp (n = 1) in its upper margin, and was sometimes double lined in the inferior margin (n = 3). CT revealed the anterior mediastinal fat to be the cause of the radiographic sail sign, which stretched laterally from the mediastinum to insinuate into the minor fissure. Conclusion: The incidence of sail sign on adult chest radiographs is about 0.1%. The sign is specific enough to eliminate the need for more sophisticated imaging

  1. Adult sail sign: radiographic and computed tomographic features.

    Science.gov (United States)

    Lee, Yu-Jin; Han, Daehee; Koh, Young Hwan; Zo, Joo Hee; Kim, Sang-Hyun; Kim, Deog Kyeom; Lee, Jeong Sang; Moon, Hyeon Jong; Kim, Jong Seung; Chun, Eun Ju; Youn, Byung Jae; Lee, Chang Hyun; Kim, Sam Soo

    2008-02-01

    The sail sign is a well-known radiographic feature of the pediatric chest. This sign can be observed in an adult population as well, but for a different reason. To investigate the sail sign appearing in adult chest radiography. Based on two anecdotal adult cases in which frontal chest radiographs showed the sail sign, we prospectively screened radiographs of 10,238 patients to determine the incidence of the sail sign found in adults in their 40s or older. The cause of the sail sign was assessed using computed tomography (CT). The sail sign was revealed in 10 (seven males, three females; median age 60.6 years) of 10,238 patients. Of these 10 patients with a sail sign on frontal radiographs, eight underwent CT. The frontal radiographs of these 10 patients showed a concave superior margin toward the lung in nine patients, a concave inferior margin in five, and a double-lined inferior margin in three. Lateral radiographs disclosed a focal opacity over the minor fissure in five of six patients, which was either fuzzy (n = 4) or sharp (n = 1) in its upper margin, and was sometimes double lined in the inferior margin (n = 3). CT revealed the anterior mediastinal fat to be the cause of the radiographic sail sign, which stretched laterally from the mediastinum to insinuate into the minor fissure. The incidence of sail sign on adult chest radiographs is about 0.1%. The sign is specific enough to eliminate the need for more sophisticated imaging.

  2. Evaluation of computed tomography post-processing images in postoperative assessment of Lisfranc injuries compared with plain radiographs.

    Science.gov (United States)

    Li, Haobo; Chen, Yanxi; Qiang, Minfei; Zhang, Kun; Jiang, Yuchen; Zhang, Yijie; Jia, Xiaoyang

    2017-06-14

    The objective of this study is to evaluate the value of computed tomography (CT) post-processing images in postoperative assessment of Lisfranc injuries compared with plain radiographs. A total of 79 cases with closed Lisfranc injuries that were treated with conventional open reduction and internal fixation from January 2010 to June 2016 were analyzed. Postoperative assessment was performed by two independent orthopedic surgeons with both plain radiographs and CT post-processing images. Inter- and intra-observer agreement were analyzed by kappa statistics while the differences between the two postoperative imaging assessments were assessed using the χ 2 test (McNemar's test). Significance was assumed when p processing images was much higher than that of plain radiographs. Non-anatomic reduction was more easily identified in patients with injuries of Myerson classifications A, B1, B2, and C1 using CT post-processing images with overall groups (p processing images with overall groups (p processing images can be more reliable than plain radiographs in the postoperative assessment of reduction and implant placement for Lisfranc injuries.

  3. How Informative are the Vertical Buoyancy and the Prone Gliding Tests to Assess Young Swimmers’ Hydrostatic and Hydrodynamic Profiles?

    Science.gov (United States)

    Barbosa, Tiago M.; Costa, Mário J.; Morais, Jorge E; Moreira, Marc; Silva, António J.; Marinho, Daniel A.

    2012-01-01

    The aim of this research was to develop a path-flow analysis model to highlight the relationships between buoyancy and prone gliding tests and some selected anthropometrical and biomechanical variables. Thirty-eight young male swimmers (12.97 ± 1.05 years old) with several competitive levels were evaluated. It were assessed the body mass, height, fat mass, body surface area, vertical buoyancy, prone gliding after wall push-off, stroke length, stroke frequency and velocity after a maximal 25 [m] swim. The confirmatory model included the body mass, height, fat mass, prone gliding test, stroke length, stroke frequency and velocity. All theoretical paths were verified except for the vertical buoyancy test that did not present any relationship with anthropometrical and biomechanical variables nor with the prone gliding test. The good-of-fit from the confirmatory path-flow model, assessed with the standardized root mean square residuals (SRMR), is considered as being close to the cut-off value, but even so not suitable of the theory (SRMR = 0.11). As a conclusion, vertical buoyancy and prone gliding tests are not the best techniques to assess the swimmer’s hydrostatic and hydrodynamic profile, respectively. PMID:23486528

  4. Soliton Gases and Generalized Hydrodynamics

    Science.gov (United States)

    Doyon, Benjamin; Yoshimura, Takato; Caux, Jean-Sébastien

    2018-01-01

    We show that the equations of generalized hydrodynamics (GHD), a hydrodynamic theory for integrable quantum systems at the Euler scale, emerge in full generality in a family of classical gases, which generalize the gas of hard rods. In this family, the particles, upon colliding, jump forward or backward by a distance that depends on their velocities, reminiscent of classical soliton scattering. This provides a "molecular dynamics" for GHD: a numerical solver which is efficient, flexible, and which applies to the presence of external force fields. GHD also describes the hydrodynamics of classical soliton gases. We identify the GHD of any quantum model with that of the gas of its solitonlike wave packets, thus providing a remarkable quantum-classical equivalence. The theory is directly applicable, for instance, to integrable quantum chains and to the Lieb-Liniger model realized in cold-atom experiments.

  5. Common pitfalls in radiographic interpretation of the Thorax

    International Nuclear Information System (INIS)

    Godshalk, C.P.

    1994-01-01

    Errors in radiographic interpretation of the thorax are common. Many mistakes result from interpreting normal anatomic variants as abnormalstructures, such as misdiagnosing dorsal and rightward deviation of the cranial thoracic trachea on lateral radiographs of normal dogs. Some of the more common errors specifically relate to misinterpretation of radiographs made on obese patients. The age of the patient also plays a role in misdiagnosis. Aging cats seem to have a horizontally positioned heart on lateral radiographs, and older dogs, primarily collies,often have pulmonary osteomas that are misdiagnosed as metastatic neoplastic disease or healed pulmonary fungal infections

  6. Method for taking X radiographs

    International Nuclear Information System (INIS)

    Orth, G.

    1983-01-01

    The method is aimed at obtaining X radiographs of any human organ with the aid of an X-ray-shadowless radiation detector of a dose measuring device, which is arranged between patient and imaging system, and of a controlling microprocessor system, so that the image-forming parameters are automatically adjusted to the specific properties of the patient. This procedure minimices the efforts in preparing the radiograph and the radiation exposure of the patient

  7. Radiographic estimation in seropositive and seronegative rheumatoid arthritis.

    Science.gov (United States)

    Sahatçiu-Meka, Vjollca; Rexhepi, Sylejman; Manxhuka-Kërliu, Suzana; Rexhepi, Mjellma

    2011-08-01

    Long since it have been suggested that a subpopulation of patients with rheumatoid arthritis, diagnosed with negative rheumatoid factor tests, represents a clinical entity quite distinct from that of seropositive rheumatoid arthritis (RA). Our aim was to establish a scientific comparative analysis between seronegative and seropositive rheumatoid arthritis, regarding some radiological and clinical parameters, applied for the first time on patients from Kosovo. Two hundred fifty patients with rheumatoid arthritis according to the American College of Rheumatology criteria were retrospectively studied by analysis the radiographic damage and clinical parameters of the disease, using a data base. All examinees were between 25-60 years of age (Xb=49.96, SD=10.37) with disease duration between 1-27 years (Xb = 6.41, SD=6.47). All patients underwent a standardised evaluation radiographs. Baseline standardised poster anterior radiographs of hands and feet and radiographs of other joints, depending on indications, were assessed. Erythrocyte sedimentation rate values correlated with the radiological damages and statistical difference was found for seronegative subset (r=0.24, p<0.01). Longer duration of the disease resulted in the increase of radiological changes in both subsets (r=0.66, p<0.01) seronegative, (r=0.49, p<0.01) seropositive. Anatomic changes of IInd and IIIrd level were nearly equally distributed in both subsets, 76 (60.8%) seronegative, 75 (60%) seropositive. Radiological damages are nearly equal in both subsets, elevate in relation to the duration of the disease and correlate with ESR values. Regarding the sero-status, differences within sex, with some exceptions, are not relevant. Although there are some definite quantitative and qualitative differences regarding sero-status, obviously there is a great deal of overlap between the two groups.

  8. Radiographic estimation in seropositive and seronegative rheumatoid arthritis

    Directory of Open Access Journals (Sweden)

    Vjollca Sahatçiu-Meka

    2011-08-01

    Full Text Available Long since it have been suggested that a subpopulation of patients with rheumatoid arthritis, diagnosed with negative rheumatoid factor tests, represents a clinical entity quite distinct from that of seropositive rheumatoid arthritis (RA. Our aim was to establish a scientific comparative analysis between seronegative and seropositive rheumatoid arthritis, regarding some radiological and clinical parameters, applied for the first time on patients from Kosovo. Two hundred fifty patients with rheumatoid arthritis according to the American College of Rheumatology criteria were retrospectively studied by analysis the radiographic damage and clinical parameters of the disease, using a data base. All examinees were between 25-60 years of age (Xb=49.96, SD=10.37 with disease duration between 1-27 years (Xb = 6.41, SD=6.47. All patients underwent a standardised evaluation radiographs. Baseline standardised poster anterior radiographs of hands and feet and radiographs of other joints, depending on indications, were assessed. Erythrocyte sedimentation rate values correlated with the radiological damages and statistical difference was found for seronegative subset (r=0.24, p<0.01. Longer duration of the disease resulted in the increase of radiological changes in both subsets (r=0.66, p<0.01 seronegative, (r=0.49, p<0.01 seropositive. Anatomic changes of IInd and IIIrd level were nearly equally distributed in both subsets, 76 (60.8% seronegative, 75 (60% seropositive. Radiological damages are nearly equal in both subsets, elevate in relation to the duration of the disease and correlate with ESR values. Regarding the sero-status, differences within sex, with some exceptions, are not relevant. Although there are some definite quantitative and qualitative differences regarding sero-status, obviously there is a great deal of overlap between the two groups.

  9. Neonates do not need to be handled for radiographs

    International Nuclear Information System (INIS)

    Slade, Dawn; Alfaham, Mazin; Davis, Peter; Tuthill, David; Harrison, Sara; Morris, Susan; Guildea, Zoe

    2005-01-01

    The handling of sick neonates may have detrimental effects such as hypoxia or bradycardia. Such handling is inevitable due to the frequent need for practical procedures; however, minimising handling reduces these adverse events and may improve outcome. Radiography is one of the commonest procedures performed on neonates. Usually the infant is lifted and placed onto the radiographic cassette; however, modern incubators often incorporate a tray beneath the mattress in which the radiographic cassette can be placed without the need to disturb the infant. To compare the quality of chest radiographs taken using the standard direct contact method, with those taken using the under-tray technique. A series of chest radiographs taken over a 21-month period were analysed independently by two consultant paediatric radiologists unaware of the radiographic details. The position of the radiograph, i.e. direct contact or under-tray, was determined by the radiographer. Radiographic quality was scored on the following features: exposure, blurring, rotation, cut-off or coning, and side markers. A subjective score was also included. The results from each radiologist were analysed separately. Seventy chest radiographs were analysed - 25 standard method, 45 under-tray. A statistically significant advantage for the under-tray method was seen on two analyses - radiologist 1 for exposure, and radiologist 2 for cut-off. No other significant differences were noted. There were no differences in the infants' weights or radiation exposure. The under-tray method for taking radiographs may produce films of at least equivalent quality to the standard method. Since the standard method involves handling with potential desaturation and bradycardia, this technique should cease. (orig.)

  10. Radiographic evaluation of dentigerous cyst with cone beam CT

    International Nuclear Information System (INIS)

    Park, Yong Chan; Lee, Wan; Lee, Byung Do

    2010-01-01

    The purpose of this study was to accurately analyze the radiographic characteristics of dentigerous cyst (DC) with multiplanar images of cone beam computed tomography (CBCT). Thirty eight radiographically and histopathologically proven cases of DCs were analyzed with panoramic radiograph and CBCT, retrospectively. The radiographic CT pattern, symmetry of radiolucency around the unerupted tooth crown, ratio of long length to short length, degree of cortical bone alternation, effects on adjacent tooth, and cyst size were analyzed. Relative frequencies of these radiographic features were evaluated. In order to compare the CBCT features of DC with those of odontogenic keratocyst (OKC), 9 cases of OKCs were analyzed with the same method radiographically. DCs consisted of thirty unilocular cases (79.0%), seven lobulated cases (18.4%) and one multilocular case (2.6%). Eight were asymmetric (21.0%) and thirty were symmetric (79.0%). Maxillary DC showed rounder shape than mandibular DC (L/S ratio; maxilla 1.32, mandible 1.67). Alternations of lingual cortical bone (14 cases, 48.2%) were more frequent than those of buccal side (7 cases, 24.1%). CBCT images of DC showed definite root resorption and bucco-lingual tooth displacement. These findings were hardly observed on panoramic radiographs of DCs. Comparison of CBCT features of DC with those of OKC showed several different features. CBCT images of DC showed various characteristic radiographic features. Therefore, CBCT can be helpful for the diagnosis of DC radiographically.

  11. Radiographic evaluation of dentigerous cyst with cone beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yong Chan; Lee, Wan; Lee, Byung Do [School of Dentisity, Wonkwang University, Iksan (Korea, Republic of)

    2010-09-15

    The purpose of this study was to accurately analyze the radiographic characteristics of dentigerous cyst (DC) with multiplanar images of cone beam computed tomography (CBCT). Thirty eight radiographically and histopathologically proven cases of DCs were analyzed with panoramic radiograph and CBCT, retrospectively. The radiographic CT pattern, symmetry of radiolucency around the unerupted tooth crown, ratio of long length to short length, degree of cortical bone alternation, effects on adjacent tooth, and cyst size were analyzed. Relative frequencies of these radiographic features were evaluated. In order to compare the CBCT features of DC with those of odontogenic keratocyst (OKC), 9 cases of OKCs were analyzed with the same method radiographically. DCs consisted of thirty unilocular cases (79.0%), seven lobulated cases (18.4%) and one multilocular case (2.6%). Eight were asymmetric (21.0%) and thirty were symmetric (79.0%). Maxillary DC showed rounder shape than mandibular DC (L/S ratio; maxilla 1.32, mandible 1.67). Alternations of lingual cortical bone (14 cases, 48.2%) were more frequent than those of buccal side (7 cases, 24.1%). CBCT images of DC showed definite root resorption and bucco-lingual tooth displacement. These findings were hardly observed on panoramic radiographs of DCs. Comparison of CBCT features of DC with those of OKC showed several different features. CBCT images of DC showed various characteristic radiographic features. Therefore, CBCT can be helpful for the diagnosis of DC radiographically.

  12. A contribution of quality assurance in veterinary radiography: further development and calibration of a test phantom to control the radiographic quality of X-rays of the equine hock joint

    International Nuclear Information System (INIS)

    Grohmann, D.

    1996-10-01

    The test phantom, which was elaborated by PARISOT (1988), was further developed and calibrated for the equine hock joint. As bigger bone layers had to be radiated, in comparison with the already existing calibration, a new material with higher radiographic density was used for the construction of a new test phantom. A copper test phantom, constructed like a staircase, containing drill-holes in the bottom plate, was used. This practical test phantom, on the highest step only 2.3 mm thick, should prove to be small enough to suit to the daily use in the equine practice. The photographs of each of the views were judged by a specialist in equine medicine and classified into three groups with the criteria 'too light', 'good' and 'too dark'. Then 15 test subjects determined the upper limit of the visibility of the two drillings. After statistical analysis of the data, standard ranges for the three photographing directions were fixed and nomograms were made. As a result of simultaneous photographing of the test phantom and the hock joint of interest, the observer is able to assess the quality of the radiograph. Determining the upper limit of visibility of the holes in the staircase, he can judge the photograph as suitable, too light or too dark for diagnostic use. (author)

  13. Relationships between rotator cuff tear types and radiographic abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Soo Hyun; Chun, Kyung Ah; Lee Soo Jung; Kang, Min Ho; Yi, Kyung Sik; Zhang, Ying [Dept. of Diagnostic Radiology, College of Medicine, Chungbuk National University, Cheongju (Korea, Republic of)

    2014-11-15

    To determine relationships between different types of rotator cuff tears and radiographic abnormalities. The shoulder radiographs of 104 patients with an arthroscopically proven rotator cuff tear were compared with similar radiographs of 54 age-matched controls with intact cuffs. Two radiologists independently interpreted all radiographs for; cortical thickening with subcortical sclerosis, subcortical cysts, osteophytes in the humeral greater tuberosity, humeral migration, degenerations of the acromioclavicular and glenohumeral joints, and subacromial spurs. Statistical analysis was performed to determine relationships between each type of rotator cuff tears and radiographic abnormalities. Inter-observer agreements with respect to radiographic findings were analyzed. Humeral migration and degenerative change of the greater tuberosity, including sclerosis, subcortical cysts, and osteophytes, were more associated with full-thickness tears (p < 0.01). Subacromial spurs were more common for full-thickness and bursal-sided tears (p < 0.01). No association was found between degeneration of the acromioclavicular or glenohumeral joint and the presence of a cuff tear. Different types of rotator cuff tears are associated with different radiographic abnormalities.

  14. Relationships between rotator cuff tear types and radiographic abnormalities

    International Nuclear Information System (INIS)

    Lee, Soo Hyun; Chun, Kyung Ah; Lee Soo Jung; Kang, Min Ho; Yi, Kyung Sik; Zhang, Ying

    2014-01-01

    To determine relationships between different types of rotator cuff tears and radiographic abnormalities. The shoulder radiographs of 104 patients with an arthroscopically proven rotator cuff tear were compared with similar radiographs of 54 age-matched controls with intact cuffs. Two radiologists independently interpreted all radiographs for; cortical thickening with subcortical sclerosis, subcortical cysts, osteophytes in the humeral greater tuberosity, humeral migration, degenerations of the acromioclavicular and glenohumeral joints, and subacromial spurs. Statistical analysis was performed to determine relationships between each type of rotator cuff tears and radiographic abnormalities. Inter-observer agreements with respect to radiographic findings were analyzed. Humeral migration and degenerative change of the greater tuberosity, including sclerosis, subcortical cysts, and osteophytes, were more associated with full-thickness tears (p < 0.01). Subacromial spurs were more common for full-thickness and bursal-sided tears (p < 0.01). No association was found between degeneration of the acromioclavicular or glenohumeral joint and the presence of a cuff tear. Different types of rotator cuff tears are associated with different radiographic abnormalities.

  15. Hydrodynamic aspects of flotation separation

    Directory of Open Access Journals (Sweden)

    Peleka Efrosyni N.

    2016-01-01

    Full Text Available Flotation separation is mainly used for removing particulates from aqueous dispersions. It is widely used for ore beneficiation and recovering valuable materials. This paper reviews the hydrodynamics of flotation separations and comments on selected recent publications. Units are distinguished as cells of ideal and non-ideal flow. A brief introduction to hydrodynamics is included to explain an original study of the hybrid flotation-microfiltration cell, effective for heavy metal ion removal.

  16. A clinico-radiographic study to compare and co-relate sagittal condylar guidance determined by intraoral gothic arch tracing method and panoramic radiograph in completely edentulous patients.

    Science.gov (United States)

    Shetty, Sanath; Kunta, Mythili; Shenoy, Kamalakanth

    2018-01-01

    The purpose of this study was to compare and correlate sagittal condylar guidance determined by intraoral gothic arch tracing method and panoramic radiograph in edentulous patients. Twelve completely edentulous patients were selected by the inclusion and exclusion criteria. Conventional steps in the fabrication of complete denture till jaw relation were carried out. Intraoral gothic arch tracing and protrusive interocclusal records were obtained for each patient. Protrusive interocclusal record was used to program the Hanau Wide-Vue semi-adjustable articulator, thus obtaining the sagittal condylar guidance angle. Using RadiAnt DICOM software, on the orthopantomogram obtained for each patient in the study, two reference lines were drawn. The Frankfort's horizontal plane and the mean curvature line (joining the most superior and the inferior points on the glenoid fossa curvature) were drawn. The mean curvature line was extended to intersect the Frankfort's horizontal plane, thus obtaining the radiographic sagittal condylar guidance angle. The condylar guidance angles obtained by these two methods were compared and subjected to paired t -test. There was no statistically significant difference between the sagittal condylar guidance angles obtained between right and left sides with intraoral gothic arch tracing and radiographic methods ( P = 0.107 and 0.07, respectively). Within the limitations of this study, it was concluded that the protrusive condylar guidance angles obtained by panoramic radiograph may be used for programming semi-adjustable articulators.

  17. Radiographic inspection on offshore platforms

    International Nuclear Information System (INIS)

    Soares, Sergio Damasceno; Sperandio, Augusto Gasparoni

    1994-01-01

    One of the great challenges for non-destructive inspection is on offshore platforms, where safety is a critical issue. Inspection by gammagraphy is practically forbidden on the platform deck due to problems to personnel safety and radiological protection. Ir-192 sources are used and the risk of an accident with loss of radioisotope must be considered. It is unfeasible to use gammagraphy, because in case of an accident the rapid evacuation from the platform would be impossible. This problem does not occur when X-ray equipment is used as the radiation source. The limited practicality and portability of the X-ray equipment have prevented its use as a replacement for the gammagraphy. This paper presents the preliminary tests to see the viable use of radiographic tests with constant potential on offshore platforms. (author). 2 refs., 1 fig., 2 tabs, 3 photos

  18. Thickness Evaluation of Pipeline Using Density Profile on a Radiograph

    International Nuclear Information System (INIS)

    Lee, Sung Sik; Jang, Byoung Gyu; Kim, Young H.

    2002-01-01

    The computer simulation has been done for non-insulated and insulated pipes which are vacant or half filled with liquid. The simulation results showed that the density profile on the radiography is continuous and symmetrical around the center of pipe in the case of vacant pipe. On the other hand the density profiles are not symmetrical and depend on geometrical setting for radiography in the case of half filled pipes. Finally, experimental testing on a non-insulated carbon steel pipe with artificial notches of different depth is carried out using Ir-192 and industrial film. Comparing the measured density profile on the radiograph to the calculated one, it has been shown that it is possible to evaluate thickness variation by measuring density profile on a radiograph

  19. Hydrodynamic bearings

    CERN Document Server

    Bonneau, Dominique; Souchet, Dominique

    2014-01-01

    This Series provides the necessary elements to the development and validation of numerical prediction models for hydrodynamic bearings. This book describes the rheological models and the equations of lubrication. It also presents the numerical approaches used to solve the above equations by finite differences, finite volumes and finite elements methods.

  20. Appearance of the mandibular incisive canal on panoramic radiographs

    NARCIS (Netherlands)

    Jacobs, R.; Mraiwa, N.; van Steenberghe, D.; Sanderink, G.C.H.; Quirynen, M.

    2004-01-01

    Panoramic radiographs are routinely used in the dental office for various diagnostic purposes. This study aimed to evaluate the visibility of neurovascular structures in the mandibular interforaminal region on such radiographs. Panoramic radiographs were obtained with a Cranex Tome (Soredex) from

  1. Radiographic evaluation of degenerative joint disease in horses: interpretive principles

    International Nuclear Information System (INIS)

    Widmer, W.R.; Blevins, W.E.

    1994-01-01

    Degenerative joint disease in horses is characterized by the progressive deterioration of articular cartilage of synovial joints. The morbidity associated with degenerative joint disease, particularly the loss of function in pleasure and performance horses, costs horse owners millions of dollars each year. Although new drugs, such as polysulfated glycosaminoglycans and hyaluronic acid, are available for the treatment of patients with degenerative joint disease, the success of therapy depends on early diagnosis. Diagnostic imaging strategies, therefore, should focus on accurate and timely diagnosis of degenerative joint disease to provide prompt therapy. Early identification of degenerative joint disease is also beneficial because the use and/or training methods of affected patients may be altered, possibly limiting the progression of the disease. The pathogenesis of degenerative joint disease is complex and multifactorial. Current evidence suggests that initiating factors lead to a final common pathway-breakdown of articular cartilage. There are many diagnostic tests that aid practitioners in detecting degenerative joint disease; however, the most important imaging technique is radiography. During the early stages of the disease, radiographic changes may be slight; therefore, it is essential that practitioners have adequate equipment to obtain high-quality radiographs. Thinning of the joint space, osteophytosis, enthesopathy, changes in subchondral bone, and increased synovium and synovia provide radiographic evidence of degenerative joint disease. By understanding the pathophysiology of the disease and how technical alterations affect the subtle radiographic changes, practitioners can more accurately diagnose degenerative joint disease during its early stages and institute proper therapy

  2. Radiographic testing of concrete

    International Nuclear Information System (INIS)

    Porter, James F.

    1997-01-01

    The increase in construction activity in the Philippines, reinforced concrete building is still a favorite among designers, because it is much cheaper to build and it requires qualified welders, etc. and extensive nondestructive testing and inspection of metals, welds and castings. Of all the techniques radiography is widely used for concrete

  3. Hydrodynamic dispersion of microswimmers in suspension

    Science.gov (United States)

    Martin, Matthieu; Rafaï, Salima; Peyla, Philippe

    2014-11-01

    In our laboratory, we study hydrodynamics of suspensions of micro-swimmers. These micro-organisms are unicellular algae Chlamydomonas Rheinhardii which are able to swim by using their flagella. The swimming dynamics of these micro-swimmers can be seen as a random walk, in absence of any kind of interaction. In addition, these algae have the property of being phototactic, i.e. they swim towards the light. Combining this property with a hydrodynamic flow, we were able to reversibly separate algae from the rest of the fluid. But for sufficiently high volume fraction, these active particles interact with each other. We are now interested in how the coupling of hydrodynamic interactions between swimmers and phototaxis can modify the swimming dynamics at the scale of the suspension. To this aim, we conduct experiments in microfluidic devices to study the dispersion of the micro-organisms in a the liquid phase as a function of the volume fraction. We show that the dispersion of an assembly of puller type microswimmers is quantitatively affected by hydrodynamics interactions. Phd student.

  4. Weightbearing vs Gravity Stress Radiographs for Stability Evaluation of Supination-External Rotation Fractures of the Ankle.

    Science.gov (United States)

    Seidel, Angela; Krause, Fabian; Weber, Martin

    2017-07-01

    Isolated lateral malleolar fractures may result from a supination-external rotation (SER) injury of the ankle. Stable fractures maintain tibiotalar congruence due to competent medial restraints and can be treated nonoperatively with excellent functional results and long-term prognosis. Stability might be assessed with either stress radiographs or weightbearing radiographs. A consecutive series of patients with closed SER fractures (presumed AO 44-B1) were prospectively enrolled from 2008 to 2015. Patients with clearly unstable fractures (medial clear space more than 7 mm) on the initial nonweightbearing radiograph were excluded and operated on. All other patients were examined with a gravity stress and a weightbearing anteroposterior radiograph. Borderline instability of the fracture was assumed when the medial clear space was 4 to 7 mm. Those were treated nonoperatively. Of 104 patients with isolated lateral malleolar fractures of the SER type, 14 patients were treated operatively because of clear instability (displacement) on the initial radiographs. Of the nonoperative patients, 44 patients demonstrated borderline instability on the gravity stress but stability on the weightbearing radiograph ("gravity borderline"); the remaining 46 were stable in both tests ("gravity stable"). At an average follow-up of 23 months, no significant differences were seen in the American Orthopaedic Foot & Ankle Society hindfoot score (92 points gravity-borderline group vs 93 points gravity-unstable group), the Foot Functional Index score (11 vs 10 points), the Short Form 36 (SF-36) physical component (86 vs 85 points), and SF-36 mental component (84 vs 81 points). Radiographically, all fractures had healed with anatomic congruity of the ankle. Weightbearing radiographs provided a reliable basis to decide about stability and nonoperative treatment in isolated lateral malleolar fractures of the SER type with excellent clinical and radiographic outcome at short-term follow-up. Gravity

  5. The radiographic manifestations of hypochondroplasia

    International Nuclear Information System (INIS)

    Heselson, N.G.; Cremin, B.J.; Beighton, P.

    1979-01-01

    Hypochrondroplasia is an inherited skeletal dysplasia that resembles achondroplasia in mild degree. Radiographic manifestations encountered in 12 affected individuals in South Africa include slight shortening of all segments of the tubular bones, moderate caudal diminution of the lumbar interpedicular distances, increased lumbar lordosis with cacral tilt and distal prolongation of the fibular. Hypochondroplasia can be distinguished from other osteochondrodystrophies such as achondroplasia, pseudo-achondroplasia and metaphyseal chondroplasia by the recognition of it clinical and radiographic manifestations. (author)

  6. Evaluation of the radiopacities of four different root canal sealers by digital radiographic technique

    Directory of Open Access Journals (Sweden)

    Özgür Özdemir

    2016-05-01

    Full Text Available OBJECTIVE: The aim of this study was to compare the radiopacities of four different root canal sealers and gutta-percha. MATERIALS AND METHOD: AH Plus, iRootSP, MTA Fillapex and Sealapex as root canal sealers and gutta-percha cones were tested. Standardized discs of the root canal sealers and the gutta-percha were prepared. Digital radiographs of the discs and an aluminum penetrometer were obtained by using a phosphor plate. The radiographic density of the sealers and the gutta-percha were measured by using the digital radiographic system’s own measurement tool, and equivalent aluminum thicknesses were determined by using an image editing software. Differences among radiopacities of the root canal sealers and the gutta-percha were analyzed using One-way ANOVA and Tukey post-hoc tests. RESULTS: Aluminum thickness equivalents of the radiopacity values of the samples, in descending order, were: AH Plus, Sealapex, iRootSP, MTA Fillapex and gutta-percha. No significant difference was found between the radiopacity values of AH Plus and Sealapex (p>0.05. There were statistically significant differences between these two groups (AH Plus and Sealapex and all other experimental groups (p<0.05. CONCLUSION: AH Plus and Sealapex exhibited the highest radiopacity values among tested groups. In addition, all tested materials fulfilled the minimum standard value requirements suggested by International Standardization Organization and American National Standards Institute.

  7. Tuning bacterial hydrodynamics with magnetic fields

    Science.gov (United States)

    Pierce, C. J.; Mumper, E.; Brown, E. E.; Brangham, J. T.; Lower, B. H.; Lower, S. K.; Yang, F. Y.; Sooryakumar, R.

    2017-06-01

    Magnetotactic bacteria are a group of motile prokaryotes that synthesize chains of lipid-bound, magnetic nanoparticles called magnetosomes. This study exploits their innate magnetism to investigate previously unexplored facets of bacterial hydrodynamics at surfaces. Through use of weak, uniform, external magnetic fields and local, micromagnetic surface patterns, the relative strength of hydrodynamic, magnetic, and flagellar force components is tuned through magnetic control of the bacteria's orientation. The resulting swimming behaviors provide a means to experimentally determine hydrodynamic parameters and offer a high degree of control over large numbers of living microscopic entities. The implications of this controlled motion for studies of bacterial motility near surfaces and for micro- and nanotechnology are discussed.

  8. Industrial radiography on radiographic paper

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1977-11-01

    An investigation was performed to compare the quality of radiographic paper with that of X-ray film, after a review had been made of the rather scarce literature on the subject. The equipment used throughout the investigation is described, and characteristic curves for Agfa-Gevaert and Kodak papers exposed with different intensifying screens in the low and intermediate voltage range are reproduced. The relative speed, contrast and exposure latitude were computed from these curves. The quality of the radiographic image was checked on U/Al blocks and plates, Al and Fe blocks, and fiber-reinforced composites. Exposure charts for Al and Fe were made for various paper and screen combinations. Both the sharpness of the radiographic image as well as the influence of processing on speed and contrast were checked. Examples are given of the practical application of the paper for radiography of castings, weldings, solderings, assemblies, etc. (author)

  9. Caries detection in dental radiographs

    International Nuclear Information System (INIS)

    Dunn, S.M.

    1987-01-01

    Caries, or the decay of teeth are difficult to automatically detect in dental radiographs because of the small area of the image that is occupied by the decay. Images of dental radiographs has distinct regions of homogeneous gray levels, and therefore naturally lead to a segmentation based automatic caries detection algorithm. This paper describes a method for caries detection based on a multiclass, area independent thresholding and segmenting scheme. This multiclass thresholding algorithm is an extension of the uniform error threshold, an area independent, distribution free thresholding method used for images of only two classes of objects. The authors first consider the problem of caries detection and the image features that characterize the presence of caries. Next, the uniform error threshold is reviewed, and the general multiclass uniform error threshold algorithm is presented. This algorithm is used to automatically detect caries in dental radiographs

  10. Hydrodynamics in a Degenerate, Strongly Attractive Fermi Gas

    Science.gov (United States)

    Thomas, John E.; Kinast, Joseph; Hemmer, Staci; Turlapov, Andrey; O'Hara, Ken; Gehm, Mike; Granade, Stephen

    2004-01-01

    In summary, we use all-optical methods with evaporative cooling near a Feshbach resonance to produce a strongly interacting degenerate Fermi gas. We observe hydrodynamic behavior in the expansion dynamics. At low temperatures, collisions may not explain the expansion dynamics. We observe hydrodynamics in the trapped gas. Our observations include collisionally-damped excitation spectra at high temperature which were not discussed above. In addition, we observe weakly damped breathing modes at low temperature. The observed temperature dependence of the damping time and hydrodynamic frequency are not consistent with collisional dynamics nor with collisionless mean field interactions. These observations constitute the first evidence for superfluid hydrodynamics in a Fermi gas.

  11. Clinical and radiographic assessment of approximal carious lesions

    International Nuclear Information System (INIS)

    Espelid, I.; Tveit, A.B.

    1986-01-01

    The aim of the study was to compare the radiographic diagnosis of approximal carious lesions with visual observations of the approximal surfaces and within drilled Class II cavities (made into the pulp). Sound (n=28) and carious (n=123) approximal surfaces of extracted premolars and molars were radiographed. The radiographs were studied by seven observers to diagnose caries. Lesions without cavitation were most often classified as sound (61.3%). When lesions had cavities, the rate of detection increased to 89.1%. Sound surfaces were erroneously classified as carious in 15.7% of cases. Statistically, about 6 our of every 10 qualitative assessments of lesion depth on the basis of radiographs, correctly recorded lesions as being in enamel or extending into dentin. The interexaminer variation in radiographic caries diagnosis were mostly due to difference in diagnostic criteria, whereas differences in diagnostic capability were less important

  12. Image rejects/retakes-radiographic challenges

    International Nuclear Information System (INIS)

    Waaler, D.; Hofmann, B.

    2010-01-01

    A general held position among radiological personnel prior to digitalisation was that the problem of image rejects/retakes should more or less vanish. However, rejects/retakes still impose several challenges within radiographic imaging; they occupy unnecessary resources, expose patients to unnecessary ionizing radiation and may also indicate suboptimal quality management. The latter is the main objective of this paper, which is based on a survey of international papers published both for screen/film and digital technology. The digital revolution in imaging seems to have reduced the percentage of image rejects/retakes from 10-15 to 3-5%. The major contribution to the decrease appears to be the dramatic reduction of incorrect exposures. At the same time, rejects/retakes due to lack of operator competence (positioning, etc.) are almost unchanged, or perhaps slightly increased (due to lack of proper technical competence, incorrect organ coding, etc.). However, the causes of rejects/retakes are in many cases defined and reported with reference to radiographers' subjective evaluations. Thus, unless radiographers share common views on image quality and acceptance criteria, objective measurements and assessments of reject/retake rates are challenging tasks. Interestingly, none of the investigated papers employs image quality parameters such as 'too much noise' as categories for rejects/retakes. Surprisingly, no reject/retake analysis seems yet to have been conducted for direct digital radiography departments. An increased percentage of rejects/retakes is related to 'digital skills' of radiographers and therefore points to areas for extended education and training. Furthermore, there is a need to investigate the inter subjectivity of radiographers' perception of, and attitude towards, both technical and clinical image quality criteria. Finally, there may be a need to validate whether reject/retake rate analysis is such an effective quality indicator as has been asserted

  13. Image rejects/retakes--radiographic challenges.

    Science.gov (United States)

    Waaler, D; Hofmann, B

    2010-01-01

    A general held position among radiological personnel prior to digitalisation was that the problem of image rejects/retakes should more or less vanish. However, rejects/retakes still impose several challenges within radiographic imaging; they occupy unnecessary resources, expose patients to unnecessary ionizing radiation and may also indicate suboptimal quality management. The latter is the main objective of this paper, which is based on a survey of international papers published both for screen/film and digital technology. The digital revolution in imaging seems to have reduced the percentage of image rejects/retakes from 10-15 to 3-5 %. The major contribution to the decrease appears to be the dramatic reduction of incorrect exposures. At the same time, rejects/retakes due to lack of operator competence (positioning, etc.) are almost unchanged, or perhaps slightly increased (due to lack of proper technical competence, incorrect organ coding, etc.). However, the causes of rejects/retakes are in many cases defined and reported with reference to radiographers' subjective evaluations. Thus, unless radiographers share common views on image quality and acceptance criteria, objective measurements and assessments of reject/retake rates are challenging tasks. Interestingly, none of the investigated papers employs image quality parameters such as 'too much noise' as categories for rejects/retakes. Surprisingly, no reject/retake analysis seems yet to have been conducted for direct digital radiography departments. An increased percentage of rejects/retakes is related to 'digital skills' of radiographers and therefore points to areas for extended education and training. Furthermore, there is a need to investigate the inter-subjectivity of radiographers' perception of, and attitude towards, both technical and clinical image quality criteria. Finally, there may be a need to validate whether reject/retake rate analysis is such an effective quality indicator as has been asserted.

  14. Radiographic and Clinical Analysis of Lateral Epicondylitis.

    Science.gov (United States)

    Shillito, Matthew; Soong, Maximillian; Martin, Nicholas

    2017-06-01

    The literature suggests that radiographs may be unnecessary in the initial evaluation of lateral epicondylitis because treatment is rarely altered as a result of the radiographic findings. The most commonly reported radiographic finding is calcification at the lateral epicondyle. Our goal was to perform a quantitative and qualitative analysis of this finding to determine its importance and possible relationship with various clinical factors and patient-reported measures. All patients diagnosed with lateral epicondylitis by a single surgeon during a 5-year period were retrospectively reviewed. Age, sex, laterality, hand dominance, pain visual analog scale, duration of symptoms, Quick-Disability of the Arm, Shoulder, and Hand questionnaire score, and history of steroid injection were recorded. Calcifications on standard elbow radiographs, acquired digitally and viewed at 200% magnification on a 24-inch monitor, were characterized by size and relationship with the lateral epicondyle. We reviewed 245 patients diagnosed with lateral epicondylitis. A total of 115 elbows (47%) demonstrated lateral epicondyle calcifications. Patients with and without calcifications were similar with regard to clinical factors, as were patients with larger or smaller lesions. Eighty-five elbows (35%) had additional radiographic findings. Treatment was not altered by the radiographic findings in any case. Lateral epicondyle calcifications are much more common in lateral epicondylitis than previously reported, possibly owing to modern digital radiography and magnification, although they do not appear to be related to clinical factors including patient-reported measures. Thus, patients and surgeons should be careful to avoid overinterpretation of such findings. Although radiographs may be helpful in ruling out additional pathology, we did not find other clinically important contributions to the initial evaluation and management of this condition, and thus we do not recommend their routine use

  15. Early characteristic radiographic changes in mucolipidosis II

    Energy Technology Data Exchange (ETDEWEB)

    Lai, Lillian M. [Lucile Packard Children' s Hospital and Stanford University, Pediatric Radiology, Palo Alto, CA (United States); Lachman, Ralph S. [Lucile Packard Children' s Hospital and Stanford University, Pediatric Radiology, Palo Alto, CA (United States); University of California, International Skeletal Dysplasia Registry, Los Angeles, CA (United States)

    2016-11-15

    Although mucolipidosis type II has similar metabolic abnormalities to those found in all the mucopolysaccharidoses and mucolipidoses, there are distinctive diagnostic radiographic changes of mucolipidosis II in the perinatal/newborn/infant period. To describe the early characteristic radiographic changes of mucolipidosis II and to document when these changes manifest and resolve. We retrospectively reviewed radiographs and clinical records of 19 cases of mucolipidosis II from the International Skeletal Dysplasia Registry (1971-present; fetal age to 21/2 years). A radiologist with special expertise in skeletal dysplasias evaluated the radiographs. The most common abnormalities were increased vertebral body height (80%, nonspecific), talocalcaneal stippling (86%), periosteal cloaking (74%) and vertebral body rounding (50%). Unreported findings included sacrococcygeal sclerosis (54%) and vertebral body sclerosis (13%). Rickets and hyperparathyroidism-like (pseudohyperparathyroidism) changes (rarely reported) were found in 33% of cases. These changes invariably started in the newborn period and resolved by 1 year of age. The conversion from these early infantile radiographic features to dysostosis multiplex changes occurred in 41% of cases, and within the first year after birth. Several findings strongly suggest the diagnosis of mucolipidosis II, including cloaking in combination with one or more of the following radiographic criteria: talocalcaneal stippling, sacrococcygeal or generalized vertebral body sclerosis, vertebral body rounding, or rickets/hyperparathyroidism-like changes in the perinatal/newborn/infancy period. These findings are not found in the other two forms of mucolipidosis nor in any of the mucopolysaccharidoses. (orig.)

  16. Early characteristic radiographic changes in mucolipidosis II

    International Nuclear Information System (INIS)

    Lai, Lillian M.; Lachman, Ralph S.

    2016-01-01

    Although mucolipidosis type II has similar metabolic abnormalities to those found in all the mucopolysaccharidoses and mucolipidoses, there are distinctive diagnostic radiographic changes of mucolipidosis II in the perinatal/newborn/infant period. To describe the early characteristic radiographic changes of mucolipidosis II and to document when these changes manifest and resolve. We retrospectively reviewed radiographs and clinical records of 19 cases of mucolipidosis II from the International Skeletal Dysplasia Registry (1971-present; fetal age to 21/2 years). A radiologist with special expertise in skeletal dysplasias evaluated the radiographs. The most common abnormalities were increased vertebral body height (80%, nonspecific), talocalcaneal stippling (86%), periosteal cloaking (74%) and vertebral body rounding (50%). Unreported findings included sacrococcygeal sclerosis (54%) and vertebral body sclerosis (13%). Rickets and hyperparathyroidism-like (pseudohyperparathyroidism) changes (rarely reported) were found in 33% of cases. These changes invariably started in the newborn period and resolved by 1 year of age. The conversion from these early infantile radiographic features to dysostosis multiplex changes occurred in 41% of cases, and within the first year after birth. Several findings strongly suggest the diagnosis of mucolipidosis II, including cloaking in combination with one or more of the following radiographic criteria: talocalcaneal stippling, sacrococcygeal or generalized vertebral body sclerosis, vertebral body rounding, or rickets/hyperparathyroidism-like changes in the perinatal/newborn/infancy period. These findings are not found in the other two forms of mucolipidosis nor in any of the mucopolysaccharidoses. (orig.)

  17. Radiographer performed single contrast small bowel enteroclysis

    International Nuclear Information System (INIS)

    Law, Robert L.; Slack, Nicola; Harvey, Richard F.

    2005-01-01

    Aim: To analyse the technical success and reporting sensitivity of radiographer performed small bowel enteroclysis (SBE) undertaken by a specialist radiographer according to a standard technique [Nolan DJ, Cadman PJ. The small bowel enema made easy. Clinical Radiology 1987;38(3):295-301]. Methods: Patients (1413) had 1646 SBE in 10 years from May 1992 to April 2002. The original request card and the separate radiographer and consultant radiologist reports were reviewed. Where the radiology reports were discordant or inconclusive, the clinical notes were also reviewed. Results: Patients (1022) X-ray films were available. Nine hundred and forty-three (93.3%) SBEs had been successfully completed. Radiographer and consultant radiologist reporting had a 99.3% concordance. There was a 98.4% sensitivity for Crohn's disease (181 of 184 cases where Crohn's disease was the clinical final diagnosis). Overall reporting sensitivity was 93.7% although correct 'probably normal and abnormal' reporting bias suggests a sensitivity of 96.9%. Sixty of 943 (6.4%) reports were inconclusive. Of 1022 patients, 68 (6.6%) of small bowel intubations were not achieved, or else consent was withdrawn at the time of the procedure. Conclusion: Specialist radiographers can perform small bowel enteroclysis with a reporting sensitivity equal to that of a consultant radiologist. Radiographers accustomed to providing an SBE service become skilled at passing fine bore feeding tubes into the small bowel and can provide this service also

  18. Radiographic findings in pulmonary hypertension from unresolved embolism

    Energy Technology Data Exchange (ETDEWEB)

    Woodruff, W.W. III; Hoeck, B.E.; Chitwood, W.R. Jr.; Lyerly, H.K.; Sabiston, D.C. Jr.; Chen, J.T.T.

    1985-04-01

    Pulmonary artery hypertension with chronic pulmonary embolism is an uncommon entity that is potentially treatable with pulmonary embolectomy. Although the classic radiographic features have been described, several recent investigators report a significant percentage of these patients with normal chest radiographs. In a series of 22 patients, no normal radiographs were seen. Findings included cardiomegaly (86.4%) with right-sided enlargement (68.4%), right descending pulmonary artery enlargement (54.5%), azygos vein enlargement (27.3%), mosaic oligemia (68.2%), chronic volume loss (27.3%), atelectasis and/or effusion (22.7%), and pleural thickening (13.6%). Good correlation with specific areas of diminished vascularity was seen on chest radiographs compared with pulmonary angiograms.

  19. Radiographic findings in pulmonary hypertension from unresolved embolism

    International Nuclear Information System (INIS)

    Woodruff, W.W. III; Hoeck, B.E.; Chitwood, W.R. Jr.; Lyerly, H.K.; Sabiston, D.C. Jr.; Chen, J.T.T.

    1985-01-01

    Pulmonary artery hypertension with chronic pulmonary embolism is an uncommon entity that is potentially treatable with pulmonary embolectomy. Although the classic radiographic features have been described, several recent investigators report a significant percentage of these patients with normal chest radiographs. In a series of 22 patients, no normal radiographs were seen. Findings included cardiomegaly (86.4%) with right-sided enlargement (68.4%), right descending pulmonary artery enlargement (54.5%), azygos vein enlargement (27.3%), mosaic oligemia (68.2%), chronic volume loss (27.3%), atelectasis and/or effusion (22.7%), and pleural thickening (13.6%). Good correlation with specific areas of diminished vascularity was seen on chest radiographs compared with pulmonary angiograms

  20. Radiographic caries diagnosis and restorative treatment decision making

    International Nuclear Information System (INIS)

    Mileman, P.A.

    1985-01-01

    This thesis is concerned with a single diagnostic technique: the bitewing radiograph, and the way it is used by dentists to decide on patient treatment need for interproximal caries. The variation in caries diagnosis and treatment decisions using bitewing radiographs is described and the radiographic criteria of choice for minimizing over and undertreatment according to a norm are investigated. Three possible diagnostic strategies in interproximal caries diagnosis using a decision analysis approach are described and evaluated, and the effect of the reported diagnostic behaviour and knowledge of practicing Dutch dentists in their use of bitewing radiographs for the diagnosis and treatment of interproximal caries is described and analyzed. (Auth.)

  1. An introduction to astrophysical hydrodynamics

    CERN Document Server

    Shore, Steven N

    1992-01-01

    This book is an introduction to astrophysical hydrodynamics for both astronomy and physics students. It provides a comprehensive and unified view of the general problems associated with fluids in a cosmic context, with a discussion of fluid dynamics and plasma physics. It is the only book on hydrodynamics that addresses the astrophysical context. Researchers and students will find this work to be an exceptional reference. Contents include chapters on irrotational and rotational flows, turbulence, magnetohydrodynamics, and instabilities.

  2. Digital radiograph of the middle phalanx of the third finger (MP3) region as a tool for skeletal maturity assessment.

    Science.gov (United States)

    Hegde, Deepa Y; Baliga, Sudhindra; Yeluri, Ramakrishna; Munshi, A K

    2012-01-01

    To evaluate the reliability of the digital radiograph of the middle phalanx of the third finger (MP3) in skeletal maturity assessment. Fifty children (24 girls and 26 boys) belonging to the circumpubertal age-group were selected for the study. Two radiographs - lateral cephalogram and digital radiograph of the MP3 region - were taken in each child. Age assessment was based on the changes in shape of the cervical vertebrae and the epiphysis of the middle phalanx of the third finger of the left hand. The radiographs were assessed by three examiners. The inter- and intraexaminer variability were determined by the Wilcoxon rank sign test and the Kruskal-Wallis test and were found to be nonsignificant. Examiner 3 showed the best intraexaminer agreement and was selected to evaluate the radiographs for the entire study. The correlation determined between the MP3 stages and cervical vertebrae maturity index (CVMI) stages, the peak-wise distribution of the MP3 stages, and the correlation between the MP3 stages and the chronological age were found to be highly significant. Digital radiograph of the MP3 region is definitely a simple, reliable, cost-effective, and time-saving technique for the assessment of skeletal maturity.

  3. Theoretical hydrodynamics

    CERN Document Server

    Milne-Thomson, L M

    2011-01-01

    This classic exposition of the mathematical theory of fluid motion is applicable to both hydrodynamics and aerodynamics. Based on vector methods and notation with their natural consequence in two dimensions - the complex variable - it offers more than 600 exercises and nearly 400 diagrams. Prerequisites include a knowledge of elementary calculus. 1968 edition.

  4. Do general radiographic examinations resemble a person-centred environment?

    International Nuclear Information System (INIS)

    Hayre, C.M.; Blackman, S.; Eyden, A.

    2016-01-01

    Aim and objective: It is argued whether general radiographic examinations adhere to a person-centred approach within the direct digital radiography (DDR) environment. General radiographic examinations continue to increase and constitute approximately 90% of all examinations undertaken in the clinical environment. This study explored the potential impact patients experience whilst undergoing general imaging examinations. Method: An ethnographic methodology provided insight of two general radiography environments in the United Kingdom (UK) using participant observation and semi-structured interviews. Findings: The findings highlighted an ‘in and out’ culture whereby patients are ‘hurried’ and ‘rushed’ out of X-ray rooms in response to increasing time pressures experienced by diagnostic radiographers. In addition, this study challenged that patients may begin to rank ‘speed’ and ‘waiting times’ above other elements of radiographic care thus presenting new challenges for radiographers within the clinical environment. Conclusion: It is asserted that radiographers should remain holistic healthcare professionals and not begin to resemble operators on the production line. Further, it challenges whether patients are beginning to rank aspects of radiographic care within contemporary practices. Advances in knowledge: Few studies have explored the radiographer–patient relationship within the DDR environment, yet this study provides insight of person-centred practices within contemporary practices. - Highlights: • Challenges whether the use of DDR conforms to a person-centred approach. • Challenges whether radiographers are ‘treating patients as persons’ using DDR. • Patients may begin to rank ‘speed’ and ‘waiting times’ above other aspects of radiographic care.

  5. Hydrodynamic Overview at Hot Quarks 2016

    International Nuclear Information System (INIS)

    Noronha-Hostler, Jacquelyn

    2017-01-01

    Event-by-event relativistic hydrodynamics has been extremely successful in describing flow observables in heavy-ion collisions. However, the initial state and viscosity simultaneously affect comparisons to data so a discussion of experimental observables that help to distinguish the two follows. Specific problems that arise in the hydrodynamical modeling at the Beam Energy Scan are also addressed. (paper)

  6. The use of wind tunnel facilities to estimate hydrodynamic data

    Science.gov (United States)

    Hoffmann, Kristoffer; Tophøj Rasmussen, Johannes; Hansen, Svend Ole; Reiso, Marit; Isaksen, Bjørn; Egeberg Aasland, Tale

    2016-03-01

    Experimental laboratory testing of vortex-induced structural oscillations in flowing water is an expensive and time-consuming procedure, and the testing of high Reynolds number flow regimes is complicated due to the requirement of either a large-scale or high-speed facility. In most cases, Reynolds number scaling effects are unavoidable, and these uncertainties have to be accounted for, usually by means of empirical rules-of-thumb. Instead of performing traditional hydrodynamic measurements, wind tunnel testing in an appropriately designed experimental setup may provide an alternative and much simpler and cheaper framework for estimating the structural behavior under water current and wave loading. Furthermore, the fluid velocities that can be obtained in a wind tunnel are substantially higher than in a water testing facility, thus decreasing the uncertainty from scaling effects. In a series of measurements, wind tunnel testing has been used to investigate the static response characteristics of a circular and a rectangular section model. Motivated by the wish to estimate the vortex-induced in-line vibration characteristics of a neutrally buoyant submerged marine structure, additional measurements on extremely lightweight, helium-filled circular section models were conducted in a dynamic setup. During the experiment campaign, the mass of the model was varied in order to investigate how the mass ratio influences the vibration amplitude. The results show good agreement with both aerodynamic and hydrodynamic experimental results documented in the literature.

  7. An automatic approach for nondestructive radiographic inspection of pipeline weld joint; Uma abordagem automatica aplicada a inspecao radiografica nao-destrutiva de soldas em tubulacoes

    Energy Technology Data Exchange (ETDEWEB)

    Felisberto, Marcelo K.; Schneider, Guilherme A.; Centeno, Tania M.; Arruda, Lucia V.R. de [Centro Federal de Educacao Tecnologica do Parana, Curitiba, PR (Brazil). CPGEI - Programa de Pos-graduacao em Engenharia Eletrica e Informatica Industrial

    2005-07-01

    The current work contributes to the research in the area of pipelines non-destructive testing by presenting new methodologies for the automatic analysis of welds radiographs. Object recognition techniques based on genetic algorithms were used for the automatic weld bead detection. In addiction, an image digital filter was also tested in the weld bead images and, as a result, supposed defects are highlighted, making them easier to be detected. These methodologies were tested for 120 digital radiographs from carbon steel pipeline welded joints. These images were acquired by a storage phosphor system, using double-wall radiographic exposing technique with single-wall radiographic viewing, according to the ASME V code. As a result, even human vision hard-perceptible defects are automatically highlighted and extracted from the whole image to be separately analyzed. (author)

  8. RADIOGRAPHIC APPEARANCE OF PRESUMED NONCARDIOGENIC PULMONARY EDEMA AND CORRELATION WITH THE UNDERLYING CAUSE IN DOGS AND CATS.

    Science.gov (United States)

    Bouyssou, Sarah; Specchi, Swan; Desquilbet, Loïc; Pey, Pascaline

    2017-05-01

    Noncardiogenic pulmonary edema is an important cause of respiratory disease in dogs and cats but few reports describe its radiographic appearance. The purpose of this retrospective case series study was to describe radiographic findings in a large cohort of dogs and cats with presumed noncardiogenic pulmonary edema and to test associations among radiographic findings versus cause of edema. Medical records were retrieved for dogs and cats with presumed noncardiogenic edema based on history, radiographic findings, and outcome. Radiographs were reviewed to assess lung pattern and distribution of the edema. Correlation with the cause of noncardiogenic pulmonary edema was evaluated with a Fisher's exact test. A total of 49 dogs and 11 cats were included. Causes for the noncardiogenic edema were airway obstruction (n = 23), direct pulmonary injury (n = 13), severe neurologic stimulation (n = 12), systemic disease (n = 6), near-drowning (n = 3), anaphylaxis (n = 2) and blood transfusion (n = 1). Mixed, symmetric, peripheral, multifocal, bilateral, and dorsal lung patterns were observed in 44 (73.3%), 46 (76.7%), 55 (91.7%), 46 (76.7%), 46 (76.7%), and 34 (57.6%) of 60 animals, respectively. When the distribution was unilateral, pulmonary infiltration involved mainly the right lung lobes (12 of 14, 85.7%). Increased pulmonary opacity was more often asymmetric, unilateral, and dorsal for postobstructive pulmonary edema compared to other types of noncardiogenic pulmonary edema, but no other significant correlations could be identified. In conclusion, noncardiogenic pulmonary edema may present with a quite variable radiographic appearance in dogs and cats. © 2016 American College of Veterinary Radiology.

  9. Diagnostic accuracy of plain radiographs and cineradiography in diagnosing traumatic scapholunate dissociation

    International Nuclear Information System (INIS)

    Pliefke, Jenny; Eisenschenk, Andreas; Stengel, Dirk; Ekkernkamp, Axel; Rademacher, Grit; Mutze, Sven

    2008-01-01

    Missed tears of the scapholunate ligament (SLL) and scapholunate dissociation (SLD) after wrist injuries pose a high risk of post-traumatic osteoarthritis of the carpus. Plain X-rays and dynamic radiographic studies are frequently used for initial diagnostic work-up. Given the limited evidence of their accuracy, we retrospectively compared the radiographic findings of patients with suspected traumatic SLD with wrist arthroscopy as the accepted reference standard. During a 6-year period, plain radiographs and DSA cineradiography scans were obtained from 198 patients who had sustained a hyperextension injury to their hand. Of those, 102 (72 men, 30 women, mean age of 42 ± 12 years) subsequently underwent diagnostic arthroscopy. Digital images were reevaluated by experienced radiologists unaware of the arthroscopic findings for the presence or absence of SLD. We calculated the sensitivity (SN) and specificity (SP) with 95% confidence intervals (CI), and computed areas under the receiver operating characteristic curves (AUC/ROC). Arthroscopy revealed 42 SLL ruptures, 13, 10, and 19 of which were classified as grade I (partial), II (complete with dynamic instability), or III (complete with static instability) respectively. Plain radiographs correctly identified 24 injuries (SN 57.1%, 95% CI 41.0-72.3%), and produced 1 false-positive result (SP 98.3%, 95% CI 91.1-100.0%). The scapholunate distance and the SL angle contributed independently to the diagnostic variance, with an AUC/ROC of 85.7% (95% CI 76.8-92.2%). Cineradiography had a sensitivity of 36 out of 42 (85.7%, 95% CI 71.5-94.6%), and a specificity of 57 out of 60 (95.0%, 95% CI 86.1-99.0%). Pathological results on plain radiographs and cineradiography reliably indicate the presence of SLD after wrist trauma. Although non-conclusive, a negative dynamic study markedly reduces the pre-test probability of disease. Both methods remain key elements of primary diagnostic strategies for suspected traumatic SLD, and may

  10. A case of a found radiographic source

    International Nuclear Information System (INIS)

    Pucelj, B.; Korun, M.; Kavsek, D.; Kreft, Z.; Krizman, M.; Martincic, R.; Rosman, M.; Sutej, T.

    1996-01-01

    High dose-rate levels were detected outdoors in the vicinity of a bunker used for storage of radiographic sources in a plant which manufactures metallic products. The investigation revealed that radiation was due to a buried sealed radiographic source, containing 28 GBq of 137 Cs. A special republic radiological emergency team removed the source in a carefully planned operation. There was no evidence for overexposure of the population or of radiographic and other workers of the plant. The highest dose to the recovery team was 50 μSv

  11. Radiographic findings in immunodeficiency

    International Nuclear Information System (INIS)

    Obregon, R.; Lynch, D.A.; Cink, T.M.; Newell, J.D.; Kirkpatrick, C.

    1991-01-01

    This paper reviews the chest radiographs and high-resolution CT (HRCT) scans in patients with immunodeficiency disorders and define the role of HRCT. Thirty-three cases were retrospectively graded according to the consensus of two radiologists. Patients with HIV seropositivity and asthma were excluded. HRCT was performed in 12 cases with standard techniques. Diagnoses included common variable hypogammaglobulinemia (n = 19), X-linked agammaglobulinemia (n = 4), chronic mucocutaneous candidiasis (n = 4), and selective immunoglobulin g deficiencies (n = 2). Chest radiographs showed bronchiectasis in 11 of 33 cases with a predominant lower lobe distribution (82%). Nodules were present in six cases and mucus plugs in four cases. HRCT showed bronchiectasis in nine of 12 cases; in five of these nine cases, bronchiectasis was not apparent on chest radiographs. Other HRCT findings included segmental air trapping (four of 12), mucus plugs (three of 12), hazy consolidation (four of 12), nodules (five of 12), and bronchiolectasis (two of 12). Therapy was altered in seven of 12 cases in which HRCT was performed. Most pertinent to clinical management were the presence of a thymoma (n = 1) and severe focal of diffuse bronchiectasis

  12. Large Format Radiographic Imaging

    International Nuclear Information System (INIS)

    Rohrer, J. S.; Stewart, Lacey; Wilke, M. D.; King, N. S.; Baker A, S.; Lewis, Wilfred

    1999-01-01

    Radiographic imaging continues to be a key diagnostic in many areas at Los Alamos National Laboratory (LANL). Radiographic recording systems have taken on many form, from high repetition-rate, gated systems to film recording and storage phosphors. Some systems are designed for synchronization to an accelerator while others may be single shot or may record a frame sequence in a dynamic radiography experiment. While film recording remains a reliable standby in the radiographic community, there is growing interest in investigating electronic recording for many applications. The advantages of real time access to remote data acquisition are highly attractive. Cooled CCD camera systems are capable of providing greater sensitivity with improved signal-to-noise ratio. This paper begins with a review of performance characteristics of the Bechtel Nevada large format imaging system, a gated system capable of viewing scintillators up to 300 mm in diameter. We then examine configuration alternatives in lens coupled and fiber optically coupled electro-optical recording systems. Areas of investigation include tradeoffs between fiber optic and lens coupling, methods of image magnification, and spectral matching from scintillator to CCD camera. Key performance features discussed include field of view, resolution, sensitivity, dynamic range, and system noise characteristics

  13. Radiographic study on temporomandibular joint Arthrosis

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Dong Soo [Dept. of Radiology, College of Dentistry, Seoul National University , Seoul (Korea, Republic of)

    1980-11-15

    The author analysed the routine radiographic changes and clinical symptoms of 205 cases of temporomandibular joint arthrosis. The clinical symptoms of the patients were classified and the morphological changes of condylar head, articular eminence, and articular fossa were analyzed and discussed from radiographic view point. The positional change of condylar head and articular fossa relation in TMJ arthrosis were observed. The frequencies of coincidence between the site of complaints and the site of the abnormal images which could be detected were examined. The results were obtained as follows; 1. Bone erosion, deformity, marginal proliferation and sclerosis were selected from many abnormal images as the radiographic diagnostic criteria of TMJ arthritic lesions. 2. Abnormal radiographic findings were revealed in 150 cases (73.9%) of 205 total TMJ arthrosis cases and site with abnormal findings coincided with the site of complaints in 105 cases (70.7%) of 150 cases and coincidence rates were higher above fourth decades than below third decades. 3. Sclerosis of the abnormal radiographic findings could be found more often below third decades than above fourth decades. 4. The positional changes of condylar head were revealed in 176 cases (85.9%) of 205 total cases. 5. Pain complaints were revealed in 170 cases(82.9%) and clicking sounds were revealed in 120 cases (58.6%) of clinical symptoms of TMJ arthrosis. 6. No tendency was found so far the differential diagnosis between pain dysfunction syndrome and osteoarthrosis of TMJ.

  14. Radiographic study on temporomandibular joint Arthrosis

    International Nuclear Information System (INIS)

    Yoo, Dong Soo

    1980-01-01

    The author analysed the routine radiographic changes and clinical symptoms of 205 cases of temporomandibular joint arthrosis. The clinical symptoms of the patients were classified and the morphological changes of condylar head, articular eminence, and articular fossa were analyzed and discussed from radiographic view point. The positional change of condylar head and articular fossa relation in TMJ arthrosis were observed. The frequencies of coincidence between the site of complaints and the site of the abnormal images which could be detected were examined. The results were obtained as follows; 1. Bone erosion, deformity, marginal proliferation and sclerosis were selected from many abnormal images as the radiographic diagnostic criteria of TMJ arthritic lesions. 2. Abnormal radiographic findings were revealed in 150 cases (73.9%) of 205 total TMJ arthrosis cases and site with abnormal findings coincided with the site of complaints in 105 cases (70.7%) of 150 cases and coincidence rates were higher above fourth decades than below third decades. 3. Sclerosis of the abnormal radiographic findings could be found more often below third decades than above fourth decades. 4. The positional changes of condylar head were revealed in 176 cases (85.9%) of 205 total cases. 5. Pain complaints were revealed in 170 cases(82.9%) and clicking sounds were revealed in 120 cases (58.6%) of clinical symptoms of TMJ arthrosis. 6. No tendency was found so far the differential diagnosis between pain dysfunction syndrome and osteoarthrosis of TMJ.

  15. Development and assessment of an e-learning course on breast imaging for radiographers: a stratified randomized controlled trial.

    Science.gov (United States)

    Moreira, Inês C; Ventura, Sandra Rua; Ramos, Isabel; Rodrigues, Pedro Pereira

    2015-01-05

    Mammography is considered the best imaging technique for breast cancer screening, and the radiographer plays an important role in its performance. Therefore, continuing education is critical to improving the performance of these professionals and thus providing better health care services. Our goal was to develop an e-learning course on breast imaging for radiographers, assessing its efficacy, effectiveness, and user satisfaction. A stratified randomized controlled trial was performed with radiographers and radiology students who already had mammography training, using pre- and post-knowledge tests, and satisfaction questionnaires. The primary outcome was the improvement in test results (percentage of correct answers), using intention-to-treat and per-protocol analysis. A total of 54 participants were assigned to the intervention (20 students plus 34 radiographers) with 53 controls (19+34). The intervention was completed by 40 participants (11+29), with 4 (2+2) discontinued interventions, and 10 (7+3) lost to follow-up. Differences in the primary outcome were found between intervention and control: 21 versus 4 percentage points (pp), Peffect in radiographers (23 pp vs 4 pp; P=.004) but was unclear in students (18 pp vs 5 pp; P=.098). Nonetheless, differences in students' posttest results were found (88% vs 63%; P=.003), which were absent in pretest (63% vs 63%; P=.106). The per-protocol analysis showed a higher effect (26 pp vs 2 pp; Pe-learning course is effective, especially for radiographers, which highlights the need for continuing education.

  16. General relativistic hydrodynamics with Adaptive-Mesh Refinement (AMR) and modeling of accretion disks

    Science.gov (United States)

    Donmez, Orhan

    We present a general procedure to solve the General Relativistic Hydrodynamical (GRH) equations with Adaptive-Mesh Refinement (AMR) and model of an accretion disk around a black hole. To do this, the GRH equations are written in a conservative form to exploit their hyperbolic character. The numerical solutions of the general relativistic hydrodynamic equations is done by High Resolution Shock Capturing schemes (HRSC), specifically designed to solve non-linear hyperbolic systems of conservation laws. These schemes depend on the characteristic information of the system. We use Marquina fluxes with MUSCL left and right states to solve GRH equations. First, we carry out different test problems with uniform and AMR grids on the special relativistic hydrodynamics equations to verify the second order convergence of the code in 1D, 2 D and 3D. Second, we solve the GRH equations and use the general relativistic test problems to compare the numerical solutions with analytic ones. In order to this, we couple the flux part of general relativistic hydrodynamic equation with a source part using Strang splitting. The coupling of the GRH equations is carried out in a treatment which gives second order accurate solutions in space and time. The test problems examined include shock tubes, geodesic flows, and circular motion of particle around the black hole. Finally, we apply this code to the accretion disk problems around the black hole using the Schwarzschild metric at the background of the computational domain. We find spiral shocks on the accretion disk. They are observationally expected results. We also examine the star-disk interaction near a massive black hole. We find that when stars are grounded down or a hole is punched on the accretion disk, they create shock waves which destroy the accretion disk.

  17. Black Lung Benefits Act: standards for chest radiographs. Final rule.

    Science.gov (United States)

    2014-04-17

    Physicians and adjudicators use chest radiographs (X-rays) as a tool in evaluating whether a coal miner suffers from pneumoconiosis (black lung disease). Accordingly, the Department's regulations implementing the Black Lung Benefits Act allow the submission of radiographs in connection with benefit claims and set out quality standards for administering and interpreting film-based chest radiographs. This final rule updates the Department's existing film-radiograph standards and provides parallel standards for digital radiographs. This rule also updates outdated terminology and removes certain obsolete provisions.

  18. Detection of pulmonary metastatic nodules: usefulness of low-dose multidetector CT in comparison with chest radiograph

    International Nuclear Information System (INIS)

    Kim, Ki Nam; Lee, Ki Nam; Yang, Doo Kyung; Lee, Soo Keol

    2006-01-01

    We wanted to evaluate the usefulness of low-dose multidetector CT for the detection and follow-up of pulmonary metastatic nodules in patients suffering with malignancy. We retrospectively reviewed the conventional chest radiographs and low-dose multidetector CT (low-dose CT) scans of 81 patients who had been under the diagnosis of malignancy. We reviewed the detection of pulmonary nodules and we counted the number of nodules detected by each method. The nodules were confirmed by surgical operation and by the radiologic criteria. The accuracy, sensitivity, specificity and positive and negative predictive values of each method for detecting metastatic nodules were compared with χ 2 tests. Low-dose CT depicted more nodules than did chest radiograph, and the indeterminate nodules seen on chest radiograph may be clearly benign on low-dose CT (eg. calcified granulomas or bony lesions). The accuracy of low-dose CT (75.3%) was significantly higher than that of chest radiograph (49.4%) for the detection for metastatic nodules (ρ < 0.05). Low-dose CT may provide better information than does chest radiograph for diagnosing pulmonary metastasis

  19. Reflections on the role of consultant radiographers in the UK: What is a consultant radiographer?

    International Nuclear Information System (INIS)

    Booth, L.; Henwood, S.; Miller, P.

    2016-01-01

    Context: This paper is the second paper from a two year in depth case study, exploring the role of consultant radiographers in the UK. Methods: A longitudinal case study approach was used to determine the role of consultant radiographers. Interviews were used to explore experiences of being a consultant, which were analysed using thematic analysis. Eight consultant radiographers participated (Note, two of the consultants withdrew after the first interview due to workload). Therefore two consultants were interviewed only once. The remaining six consultants were interviewed twice over a 12 month period. Findings: The data presented in this paper explores the nature of the role, differences between roles, the four domains of practice, and how the role fits into local organisational structures. The study shows wide variation in the types of roles undertaken, reflecting that the creation of these roles were in response to local clinical need and often related to an individual practitioner's skills. The broad scope of the role was shown across all the consultants, with evidence of roles developing into new areas of service delivery. Conclusions: The paper offers insight into the role(s) of consultant radiographers in the UK. The range and scope of their practice is extensive, with much variation. It is evident that the clinical aspect of the role dominates, with research being the least supported domain of practice. There remains a lack of clarity around the role, with concerns about remuneration and other limitations that may restrict the role developing further. - Highlights: • This paper shows the variation in roles between consultant radiographers. • The commonality with medical roles is highlighted. • Problem solving is identified as a core skill in consultant radiography. • Consultants offered evidence of the roles developing service provision. • While all four domains of practice are covered, research is the least well supported.

  20. On the hydrodynamics and the scale-up of flotation processes

    International Nuclear Information System (INIS)

    Schubert, H.

    1986-01-01

    In flotation machines, turbulence is process-determining. Macroturbulence is necessary for suspension, microturbulence controls the air dispersion, the rate of the particle-bubble collisions and the stresses on agglomerates. Consequently, the hydrodynamic optimization of flotation processes plays an important role for the flotation efficiency. In the paper the following aspects are considered: the turbulent microprocesses of flotation processes; the integral hydrodynamic characterization of flotation processes; correlations between particle size and optimum hydrodynamics; correlations between flocculation of fine particles and optimum-hydrodynamics; and hydrodynamic scale-up of flotation processes

  1. The one-leg standing radiograph

    OpenAIRE

    Pinsornsak, P.; Naratrikun, K.; Kanitnate, S.; Sangkomkamhang, T.

    2016-01-01

    Objectives The purpose of this study was to compare the joint space width between one-leg and both-legs standing radiographs in order to diagnose a primary osteoarthritis of the knee. Methods Digital radiographs of 100 medial osteoarthritic knees in 50 patients were performed. The patients had undergone one-leg standing anteroposterior (AP) views by standing on the affected leg while a both-legs standing AP view was undertaken while standing on both legs. The severity of the osteoarthritis wa...

  2. Film holder for radiographing tubing

    International Nuclear Information System (INIS)

    Davis, E.V.; Foster, B.E.

    1976-01-01

    A film cassette is described which may be easily placed about tubing or piping and readily held in place while radiographic inspection is performed. A pair of precurved light-impervious semi-rigid plastic sheets, hinged at one edge, enclose sheet film together with any metallic foils or screens. Other edges are made light-tight with removable caps, and the entire unit is held securely about the object to be radiographed with a releasable fastener such as a strip of Velcro

  3. Film holder for radiographing tubing

    Science.gov (United States)

    Davis, Earl V.; Foster, Billy E.

    1976-01-01

    A film cassette is provided which may be easily placed about tubing or piping and readily held in place while radiographic inspection is performed. A pair of precurved light-impervious semi-rigid plastic sheets, hinged at one edge, enclose sheet film together with any metallic foils or screens. Other edges are made light-tight with removable caps, and the entire unit is held securely about the object to be radiographed with a releasable fastener such as a strip of Velcro.

  4. Development of a world wide web-based interactive education program to improve detectability of pulmonary nodules on chest radiographs

    International Nuclear Information System (INIS)

    Ohm, Joon Young; Kim, Jin Hwan; Kim, Sung Soo; Han, Ki Tae; Ahn, Young Seob; Shin, Byung Seok; Bae, Kyongtae T.

    2007-01-01

    To design and develop a World Wide Web-based education program that will allow trainees to interactively learn and improve the diagnostic capability of detecting pulmonary nodules on chest radiographs. Chest radiographs with known diagnosis were retrieved and selected from our institutional clinical archives. A database was constructed by sorting radiographs into three groups: normal, nodule, and false positive (i.e., nodule-like focal opacity). Each nodule was assigned with the degree of detectability: easy, intermediate, difficult, and likely missed. Nodules were characterized by their morphology (well-defined, ill-defined, irregular, faint) and by other associated pathologies or potentially obscuring structures. The Web site was organized into four sections: study, test, record and information. The Web site allowed a user interactively to undergo the training section appropriate to the user's diagnostic capability. The training was enhanced by means of clinical and other pertinent radiological findings included in the database. The outcome of the training was tested with clinical test radiographs that presented nodules or false positives with varying diagnostic difficulties. A World Wide Web-based education program is a promising technique that would allow trainees to interactively learn and improve the diagnostic capability of detecting and characterizing pulmonary nodules

  5. Cost-effectiveness of barium enemas performed by radiographers

    International Nuclear Information System (INIS)

    Brown, Lorraine; Desai, Sharad

    2002-01-01

    AIM: To assess the cost-effectiveness of barium enemas performed by radiographers compared to those performed by consultant radiologists. METHOD: Prospective study of 200 barium enemas carried out by a senior radiographer and a consultant radiologist. The sample was a consecutive sample of adult out-patients over a 3-month period, with no exclusion. The length of time of the enema and the numbers and grades of staff involved in the procedure were recorded. This was translated into staffing costs using the appropriate pay scales. RESULTS: The barium enemas performed by the superintendent radiographer were more cost-effective than those performed by the consultant radiologist (1406 pounds for 100 radiographer-performed barium enemas compared to 1787 pounds for 100 carried out by the consultant radiologist). CONCLUSION: In terms of staffing costs, radiographers performing barium enemas not only liberates radiologist time, it is also a cost-effective method of providing an out-patient barium enema service. Brown, L. and Desai, S. (2002)

  6. Neutron radiographic findings in light water reactor fuel

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1979-06-01

    The assessment of neutron radiographs of nuclear fuel elements can be much easier, faster and simpler if reference can be made to typical defects, which can be revealed by neutron radiography. In other fields of industrial radiography collections of reference radiographs, showing typical defects in welding, or casting have been completed and published long ago. Since 1974 neutron radiography is routinely used at Risoe National Laboratory, Denmark, for the quality and performance control of nuclear fuel. About 2000 neutron radiographs were taken, mainly during the post irradiation examination of light water reactor fuel. During assessment of neutron radiographs some typical defects of the fuel were found and it was felt that a classification of such defects will help to speed up the assessment procedure. Therefore an attempt was made to establish such a classification, which is currently used at Risoe now. This classification is presented in this atlas, which contains 36 neutron radiographs reproduced on film (in original size) and on paper (twice enlarged). (author)

  7. CT colonography: accuracy of initial interpretation by radiographers in routine clinical practice

    International Nuclear Information System (INIS)

    Burling, D.; Wylie, P.; Gupta, A.; Illangovan, R.; Muckian, J.; Ahmad, R.; Marshall, M.; Taylor, S.A.

    2010-01-01

    Aim: To investigate performance of computed-assisted detection (CAD)-assisted radiographers interpreting computed tomography colonography (CTC) in routine practice. Materials and methods: Three hundred and three consecutive symptomatic patients underwent CTC. Examinations were double-read by trained radiographers using primary two-dimensional/three-dimensional (2D/3D) analysis supplemented by 'second reader' CAD. Radiographers recorded colonic neoplasia, interpretation times, and patient management strategy code (S0, inadequate; S1, normal; S2, 6-9 mm polyp; S3, ≥10 mm polyp; S4, cancer; S5, diverticular stricture) for each examination. Strategies were compared to the reference standard using kappa statistic, interpretation times using paired t-test, learning curves using logistic regression and Pearson's correlation coefficient. Results: Of 303 examinations, 69 (23%) were abnormal. CAD-assisted radiographers detected 17/17 (100%) cancers, 21/28 (72%) polyps ≥10 mm and 42/60 (70%) 6-9 mm polyps. The overall agreement between radiographers and the reference management strategy was good (kappa 0.72; CI: 0.65, 0.78) with agreement for S1 strategy in 189/211 (90%) exams; S2 in 19/27 (70%); S3 in 12/19 (63%); S4 in 17/17 (100%); S5 in 5/6 (83%). The mean interpretation time was 17 min (SD = 11) compared with 8 min (SD = 3.5) for radiologists. There was no learning curve for recording correct strategies (OR 0.88; p = 0.12) but a significant reduction in interpretation times, mean 14 and 31 min (last/first 50 exams; -0.46; p < 0.001). Conclusion: Routine CTC interpretation by radiographers is effective for initial triage of patients with cancer, but independent reporting is currently not recommended.

  8. Hyperscaling-violating Lifshitz hydrodynamics from black-holes: part II

    Energy Technology Data Exchange (ETDEWEB)

    Kiritsis, Elias [Crete Center for Theoretical Physics, Institute of Theoretical and Computational Physics,Department of Physics, University of Crete, 71003 Heraklion (Greece); Crete Center for Quantum Complexity and Nanotechnology,Department of Physics, University of Crete, 71003 Heraklion (Greece); APC Univ Paris Diderot, Sorbonne Paris Cité,UMR 7164 CNRS, F-75205 Paris (France); Matsuo, Yoshinori [Department of Physics, National Taiwan University,Taipei 10617, Taiwan, R.O.C. (China)

    2017-03-08

    The derivation of Lifshitz-invariant hydrodynamics from holography, presented in https://www.doi.org/10.1007/JHEP12(2015)076 is generalized to arbitrary hyperscaling violating Lifshitz scaling theories with an unbroken U(1) symmetry. The hydrodynamics emerging is non-relativistic with scalar “forcing'. By a redefinition of the pressure it becomes standard non-relativistic hydrodynamics in the presence of specific chemical potential for the mass current. The hydrodynamics is compatible with the scaling theory of Lifshitz invariance with hyperscaling violation. The bulk viscosity vanishes while the shear viscosity to entropy ratio is the same as in the relativistic case. We also consider the dimensional reduction ansatz for the hydrodynamics and clarify the difference with previous results suggesting a non-vanishing bulk viscosity.

  9. Radiographic evaluation of coxofemoral joint laxity in dogs part I: New stress-radiographic positioning techniques

    International Nuclear Information System (INIS)

    Phiwipha Kamonrat; Duangdaun Kaenkangploo

    2002-01-01

    Two new stress-radiographic positioning techniques, namely 60 deg and 90 deg stress techniques, were introduced for quantifying hip joint laxity in dogs. The comparative characteristics and efficiency of these new techniques with angled hindlimbs were evaluated relative to the standard hip-extended radiographic technique. Forty, healthy, mongrel dogs with normal hip joint conformation were anesthetized and placed in dorsal recumbency before 3 radiograhps of the standard, 60 deg , and 90 deg stress techniques were taken. For the 60 deg stress technique, hindlimbs were extended in parallel to each other at 60 deg angled to the table top and stifles were slightly rotated inward, femoral heads were manually pushed in a craniodorsal direction during exposure. For the 90 deg stress technique, femurs were positioned perpendicular to the table top, stifles were 90 deg flexed and adducted and femoral heads were manually pushed in a craniodorsal direction during exposure. The subluxation index (SI) and dorsolateral subluxation score (DLS score) were calculated from 3 radiographic views for both hip joints to quantitate the relative degree of joint laxity. Results of the study indicated that the 60 deg (SI = 0.20+-0.045, DLS score = 62.5+-7.96 percent) and 90 deg (SI = 0.23+-0.044, DLS score = 61.2+-9.47 percent) stress-radiographs yielded significantly (p0.001) higher degree of hip joint laxity than the standard technique (SI)

  10. HYDRODYNAMICS OF OSCILLATING WING ON THE PITCH ANGLE

    Directory of Open Access Journals (Sweden)

    Vitalii Korobov

    2017-07-01

    Full Text Available Purpose: research of the hydrodynamic characteristics of a wing in a nonstationary stream. Methods: The experimental studies of the hydrodynamic load acting on the wing of 1.5 elongation, wich harmonically oscillated respect to the transversal axis in the frequency range of 0.2-2.5 Hz. The flow speed in the hydrodynamic tunnel ranged of 0.2-1.5 m/s. Results: The instantaneous values of the coefficients of lift and drag / thrust on the pitch angle at unsteady flow depends on the Strouhal number.Discussion: with increasing oscillation frequency coefficients of hydrodynamic force components significantly higher than the data for the stationary blowing out of the wing.

  11. Radiographic arthrosis after elbow trauma: interobserver reliability.

    NARCIS (Netherlands)

    Lindenhovius, A.; Karanicolas, P.J.; Bhandari, M.; Ring, D.; Kampen, A. van; et al.,

    2012-01-01

    PURPOSE: This study measured observer variation in radiographic rating of elbow arthrosis. METHODS: Thirty-seven independent orthopedic surgeons graded the extent of elbow arthrosis in 20 consecutive sets of plain radiographs, according to the Broberg and Morrey rating system (grade 0, normal joint;

  12. Radiographic Arthrosis After Elbow Trauma: Interobserver Reliability

    NARCIS (Netherlands)

    Lindenhovius, Anneluuk; Karanicolas, Paul Jack; Bhandari, Mohit; Ring, David; Allan, Cristopher; Axelrod, Terry; Baratz, Mark; Beingessner, Daphne; Cassidy, Charles; Coles, Chad; Conflitti, Joe; Rocca, Gregory Della; van Dijk, C. Niek; Elmans, L. H. G. J.; Feibe, Roger; Frihagen, Frede; Gosens, Taco; Greenberg, Jeffrey; Grosso, Elena; Harness, Neil; van der Heide, Huub; Jeray, Kyle; Kalainov, David; van Kampen, Albert; Kawamura, Sumito; Kloen, Peter; McCormac, Bob; McKee, Michael; Page, Richard; Pesantez, Rodrigo; Peters, Anil; Petrisor, Brad; Poolman, Rudolf; Richardson, Martin; Seiler, John; Swiontkowski, Marc; Trumble, Thomas; Wright, Thomas; Zalavras, Charalampos; Zura, Robert

    2012-01-01

    Purpose This study measured observer variation in radiographic rating of elbow arthrosis. Methods Thirty-seven independent orthopedic surgeons graded the extent of elbow arthrosis in 20 consecutive sets of plain radiographs, according to the Broberg and Morrey rating system (grade 0, normal joint;

  13. Radiographic abnormalities in tricyclic acid overdose

    International Nuclear Information System (INIS)

    Varnell, R.M.; Richardson, M.L.; Vincent, J.M.; Godwin, J.D.

    1987-01-01

    Several case reports have described adult respiratory distress syndrome (ARDS) secondary to tricyclic acid (TCA) overdose. During a 1-year period 83 patients requiring intubation secondary to drug overdose were evaluated. Abnormalities on chest radiographs occurred in 26 (50%) of the 54 patients with TCA overdose, compared to six (21%) of the 29 patients overdosed with other drugs. In addition, five (9%) of the patients with TCA overdose subsequently had radiographic and clinical abnormalities meeting the criteria for ARDS. Only one (3%) of the patients with non-TCA overdose subsequently had change suggesting ARDS. TCAs should be added to the list of drugs associated with ARDS, and TCA overdose should be considered a major risk factor in the development of radiographically evident abnormalities

  14. Opportunistic esophagitis in AIDS: Radiographic diagnosis

    International Nuclear Information System (INIS)

    Levine, M.S.; Woldenberg, R.; Herlinger, H.; Laufer, I.

    1987-01-01

    Between 1983 and 1986, 35 of 90 patients with acquired immunodeficiency syndrome (AIDS) had double-contrast esophagograms to rule out opportunistic esophagitis. The radiographs were reviewed without knowledge of the clinical or endoscopic findings. Candida esophagitis was diagnosed radiographically in 17 patients who had varying degrees of plaque formation and viral esophagitis in three who had discrete ulcers without plaques. All three patients with viral esophagitis (herpes in 2 and cytomegalo virus in one) and 15 of 17 with Candida esophagitis had endoscopic and/or clinical corroboration of the radiographic diagnosis. Thus, the authors' experience suggests that fungal and viral esophagitis can often be differentiated on double-contrast esophagography, so that appropriate antifungal or antiviral therapy can be instituted without need for endoscopic intervention

  15. Pre-procedural scout radiographs are unnecessary for routine pediatric fluoroscopic examinations

    Energy Technology Data Exchange (ETDEWEB)

    Creeden, Sean G.; Rao, Anil G.; Eklund, Meryle J.; Hill, Jeanne G.; Thacker, Paul G. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States)

    2017-03-15

    Although practice patterns vary, scout radiographs are often routinely performed with pediatric fluoroscopic studies. However few studies have evaluated their utility in routine pediatric fluoroscopy. To evaluate the value of scout abdomen radiographs in routine barium or water-soluble enema, upper gastrointestinal (GI) series, and voiding cystourethrogram pediatric fluoroscopic procedures. We retrospectively evaluated 723 barium or water-soluble enema, upper GI series, and voiding cystourethrogram fluoroscopic procedures performed at our institution. We assessed patient history and demographics, clinical indication for the examination, prior imaging findings and impressions, scout radiograph findings, additional findings provided by the scout radiograph that were previously unknown, and whether the scout radiograph contributed any findings that significantly changed management. We retrospectively evaluated 723 fluoroscopic studies (368 males and 355 females) in pediatric patients. Of these, 700 (96.8%) had a preliminary scout radiograph. Twenty-three (3.2%) had a same-day radiograph substituted as a scout radiograph. Preliminary scout abdomen radiographs/same-day radiographs showed no new significant findings in 719 (99.4%) studies. New but clinically insignificant findings were seen in 4 (0.6%) studies and included umbilical hernia, inguinal hernia and hip dysplasia. No findings were found on the scout radiographs that would either alter the examination performed or change management with regard to the exam. Pre-procedural scout abdomen radiographs are unnecessary in routine barium and water-soluble enema, upper GI series, and voiding cystourethrogram pediatric fluoroscopic procedures and can be substituted with a spot fluoroscopic last-image hold. (orig.)

  16. Radiographic features of appendiceal colic in children

    International Nuclear Information System (INIS)

    Schisgall, R.M.

    1986-01-01

    The concept of appendiceal colic was introduced in 1980 to explain the common problem of recurrent crampy abdominal pain (RAP) in children. Children with appendiceal colic often have inspissated casts of stool as foreign bodies of the appendix. The radiographic findings of 115 children operated upon for appendiceal colic have been reviewed. The radiographic features of this syndrom have included: filling defects of the appendix (83% incidence of inspissated casts of stool within the appendix); partial filling of the appendix (44% incidence of fecal casts); retained barium behind 72 h (92% incidence of fecal casts blocking egress of barium); non-visualization of the appendix (42% incidence of fecal casts); and distention of the appendix (100% incidence of fecal casts). The correlation of radiographic and operative findings will be presented. A rational approach to the radiographic workup of a child with RAP will be presented. (orig.)

  17. Engineering Hydrodynamic AUV Hulls

    Science.gov (United States)

    Allen, J.

    2016-12-01

    AUV stands for autonomous underwater vehicle. AUVs are used in oceanography and are similar to gliders. MBARIs AUVs as well as other AUVs map the ocean floor which is very important. They also measure physical characteristics of the water, such as temperature and salinity. My science fair project for 4th grade was a STEM activity in which I built and tested 3 different AUV bodies. I wanted to find out which design was the most hydrodynamic. I tested three different lengths of AUV hulls to see which AUV would glide the farthest. The first was 6 inches. The second was 12 inches and the third was 18 inches. I used clay for the nosecone and cut a ruler into two and made it the fin. Each AUV used the same nosecone and fin. I tested all three designs in a pool. I used biomimicry to create my hypothesis. When I was researching I found that long slim animals swim fastest. So, my hypothesis is the longer AUV will glide farthest. In the end I was right. The longer AUV did glide the farthest.

  18. Radiographic diagnoses and treatment decisions on approximal caries

    International Nuclear Information System (INIS)

    Espelid, I.

    1987-01-01

    Mineral loss which represents a threshold value for radiographic diagnosis, cannot be defined exactly. For clinical use 10% mineral loss in the direction of the X-ray beam may constitute a border line lesion for radiographic detection, and caries lesions without cavitation seemed to be beyond this diagnostic threshold. The degree of caries estimated by using radiographs is fairly closely related to the depth of the tissue changes recorded in the prepared cavity. Radiographic examinations more often lead to underestimation than overestimation of the degree of caries. Radiographic caries diagnoses made at different degrees of penetration toward the pulp showed insignificant variations with respect to quality, but the observers were more confident of caries being present (used more strict criterion) when they scored caries in inner dentin. Consensus on diagnostic criteria and improved diagnostic quality are considerably more important to the quality of therapeutic decisions on approximal caries than viewing conditions and film density. A semi-radiopaque material in Class II fillings seems to offer advantages compared to amalgam in respect of the diagnosis of secondary caries and marginal defects. There is a danger that dentists will restore approximal caries lesions too early and before these can be diagnosed in dentin radiographically

  19. Definitive radiotherapy for head-and-neck cancer with radiographically positive retropharyngeal nodes: Incomplete radiographic response does not necessarily indicate failure

    International Nuclear Information System (INIS)

    Liauw, Stanley L.; Mancuso, Anthony A.; Morris, Christopher G. M.S.; Amdur, Robert J.; Mendenhall, William M.

    2006-01-01

    Purpose: Our aim was to report the control rate of radiographically positive retropharyngeal (RP) nodes with radiation therapy (RT) and to correlate posttreatment imaging with clinical outcome. Methods and Materials: Sixteen patients treated with definitive RT for head-and-neck cancer had radiographically positive RP nodes (size >1 cm in largest axial dimension, or presence of focal enhancement, lucency, or calcification), and both pre-RT and post-RT image sets available for review. An additional 21 patients with unconfirmed radiographically positive RP nodes had post-RT imaging, which consisted of computed tomography (CT) at a median of 4 weeks after completing RT. Patients with positive post-RT RP nodes underwent observation with serial imaging. Results: Of 16 patients with pre-RT and post-RT images available for review, 9 (56%) had a radiographic complete response, and of 21 patients with unconfirmed positive RP nodes with post-RT images available for review, 14 (67%) had a radiographic complete response. In all, 14 patients with incomplete response on post-RT imaging experienced control of their disease with no further therapy, and no RP node or neck failures were noted during a median follow-up of 2.8 years. Six patients with positive post-RT RP nodes had serial imaging available for review, and none demonstrated radiographic progression of disease. Conclusions: Radiographic response at 4 weeks may not accurately reflect long-term locoregional control, as RP nodes may continue to resolve over time. The highest index of suspicion should be reserved for patients with progressive changes in size, focal lucency, or focal enhancement on serial imaging after RT

  20. Comparative analysis of human and bovine teeth: radiographic density

    Directory of Open Access Journals (Sweden)

    Jefferson Luis Oshiro Tanaka

    2008-12-01

    Full Text Available Since bovine teeth have been used as substitutes for human teeth in in vitro dental studies, the aim of this study was to compare the radiographic density of bovine teeth with that of human teeth to evaluate their usability for radiographic studies. Thirty bovine and twenty human teeth were cut transversally in 1 millimeter-thick slices. The slices were X-rayed using a digital radiographic system and an intraoral X-ray machine at 65 kVp and 7 mA. The exposure time (0.08 s and the target-sensor distance (40 cm were standardized for all the radiographs. The radiographic densities of the enamel, coronal dentin and radicular dentin of each slice were obtained separately using the "histogram" tool of Adobe Photoshop 7.0 software. The mean radiographic densities of the enamel, coronal dentin and radicular dentin were calculated by the arithmetic mean of the slices of each tooth. One-way ANOVA demonstrated statistically significant differences for the densities of bovine and human enamel (p 0.05. Based on the results, the authors concluded that: a the radiographic density of bovine enamel is significantly higher than that of human enamel; b the radiodensity of bovine coronal dentin is statistically lower than the radiodensity of human coronal dentin; bovine radicular dentin is also less radiodense than human radicular dentin, although this difference was not statistically significant; c bovine teeth should be used with care in radiographic in vitro studies.

  1. [The occupational radiation-induced cataract in five industrial radiographers].

    Science.gov (United States)

    Benzarti Mezni, A; Loukil, I; Hriz, N; Kallel, K; Mlaiki, N; Ben Jemaâ, A

    2012-04-01

    The industrial uses of ionizing radiation in Tunisia are expanding, especially in industry and most particularly in the nondestructive testing of welds. Thus workers operating in the non-destructive testing of welds may develop a radiation-induced cataract varying in time to onset depending on the dose. To describe the characteristics of the radiation-induced cataract in patients exposed to ionizing radiation, determine the risk factors of radiation-induced cataracts. This was an anamnestic, clinical, and environmental study of five cases of radiation-induced cataract in workers employed in non-destructive testing of welds. This series of five cases had a mean age of 30.2 years and 5.53 years of work experience, ranging from 14 months to 15 years. All the patients were male and industrial radiographers specialized in nondestructive testing of welds. The average duration of exposure to ionizing radiation was 5.53 years. None of the patients had worn protective gear such as eye goggles. The ophthalmic check-up for the five special industrial radiographers showed punctuate opacities in three cases, punctiform opacities in one eye in one case, and phacosclerosis with bilateral lens multiple crystalline stromal opacities in a case of micro-lens opacities in both eyes with opalescence of both eyes in one case. These cataracts had been declared as occupational diseases. The value of a specialized ophthalmologic surveillance among these workers and the early diagnosis of lens opacities must be emphasized. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  2. The correlation of radiographic findings and patient symptomatology in cervical degenerative joint disease: a cross-sectional study.

    Science.gov (United States)

    Rudy, Iris Sun; Poulos, Alexandra; Owen, Laura; Batters, Ashlee; Kieliszek, Kasia; Willox, Jessica; Jenkins, Hazel

    2015-01-01

    There are few known studies investigating the correlation of symptomatology with the specific subtypes of cervical spine degenerative joint disease demonstrated on radiograph. The aim of this study was to assess the correlation and diagnostic test accuracy of specific symptoms in determining the presence, type and severity of degenerative joint disease on radiograph. A retrospective cross-sectional design was used to correlate cervical radiographic findings with neck pain and related symptomatology. Radiographs of 322 patients from April 2010 to June 2012 were assessed and evidence of radiographic cervical degenerative joint disease was extracted. Clinical data for each patient was obtained from their patient files including: pain using a VAS, presence of neck stiffness, presence of headaches, presence of shoulder referral, presence of hand radiculopathy and presence of hand numbness. Measures of diagnostic test accuracy and regression analysis were used to assess for any correlation between symptoms and radiographic findings. Referral of pain to the shoulder and neck stiffness showed small degrees of correlation with cervical degenerative joint disease, however, these correlations were not maintained when age was accounted for. Only age showed consistent statistical significance as a predictor for degree of disc degeneration (correlation coefficient (95% confidence interval): 0.06 (0.055, 0.066)); the presence of facet hypertrophy (odds ratio (95% confidence interval): 1.12 (1.09, 1.15)); or uncinate process hypertrophy (odds ratio (95% confidence interval): 1.15 (1.12, 1.18)). Neck stiffness demonstrated a small degree of diagnostic test accuracy for the degree of cervical disc degeneration (area under the curve (95%CI): 0.62 (0.56, 0.68)) and the presence of either facet (diagnostic OR (95%CI):1.69 (1.04, 2.76)) and uncinated process hypertrophy (LR+ (95%CI): 1.17 (1.00, 1.38)). The results of this study indicate that clinical symptoms such as pain level

  3. Computer simulation of the fire-tube boiler hydrodynamics

    Directory of Open Access Journals (Sweden)

    Khaustov Sergei A.

    2015-01-01

    Full Text Available Finite element method was used for simulating the hydrodynamics of fire-tube boiler with the ANSYS Fluent 12.1.4 engineering simulation software. Hydrodynamic structure and volumetric temperature distribution were calculated. The results are presented in graphical form. Complete geometric model of the fire-tube boiler based on boiler drawings was considered. Obtained results are suitable for qualitative analysis of hydrodynamics and singularities identification in fire-tube boiler water shell.

  4. Boltzmann equation and hydrodynamics beyond Navier-Stokes.

    Science.gov (United States)

    Bobylev, A V

    2018-04-28

    We consider in this paper the problem of derivation and regularization of higher (in Knudsen number) equations of hydrodynamics. The author's approach based on successive changes of hydrodynamic variables is presented in more detail for the Burnett level. The complete theory is briefly discussed for the linearized Boltzmann equation. It is shown that the best results in this case can be obtained by using the 'diagonal' equations of hydrodynamics. Rigorous estimates of accuracy of the Navier-Stokes and Burnett approximations are also presented.This article is part of the theme issue 'Hilbert's sixth problem'. © 2018 The Author(s).

  5. A survey of radiographers' confidence and self-perceived accuracy in frontline image interpretation and their continuing educational preferences

    Energy Technology Data Exchange (ETDEWEB)

    Neep, Michael J [Department of Medical Imaging, Princess Alexandra Hospital, Brisbane, Queensland (Australia); Centre for Functioning and Health Research, Metro South Health, Brisbane, Queensland (Australia); School of Public Health and Social Work and Institute of Health and Biomedical Innovation, Queensland University of Technology, Brisbane, Queensland (Australia); Steffens, Tom [Department of Medical Imaging, Princess Alexandra Hospital, Brisbane, Queensland (Australia); Owen, Rebecca [Radiation Oncology Mater Centre, Princess Alexandra Hospital, Brisbane, Queensland (Australia); Faculty of Health, Queensland University of Technology, Brisbane, Queensland (Australia); McPhail, Steven M [Centre for Functioning and Health Research, Metro South Health, Brisbane, Queensland (Australia); School of Public Health and Social Work and Institute of Health and Biomedical Innovation, Queensland University of Technology, Brisbane, Queensland (Australia); Department of Medical Imaging, Princess Alexandra Hospital, Brisbane, Queensland (Australia)

    2014-06-15

    The provision of a written comment on traumatic abnormalities of the musculoskeletal system detected by radiographers can assist referrers and may improve patient management, but the practice has not been widely adopted outside the United Kingdom. The purpose of this study was to investigate Australian radiographers' perceptions of their readiness for practice in a radiographer commenting system and their educational preferences in relation to two different delivery formats of image interpretation education, intensive and non-intensive. A cross-sectional web-based questionnaire was implemented between August and September 2012. Participants included radiographers with experience working in emergency settings at four Australian metropolitan hospitals. Conventional descriptive statistics, frequency histograms, and thematic analysis were undertaken. A Wilcoxon signed-rank test examined whether a difference in preference ratings between intensive and non-intensive education delivery was evident. The questionnaire was completed by 73 radiographers (68% response rate). Radiographers reported higher confidence and self-perceived accuracy to detect traumatic abnormalities than to describe traumatic abnormalities of the musculoskeletal system. Radiographers frequently reported high desirability ratings for both the intensive and the non-intensive education delivery, no difference in desirability ratings for these two formats was evident (z = 1.66, P = 0.11). Some Australian radiographers perceive they are not ready to practise in a frontline radiographer commenting system. Overall, radiographers indicated mixed preferences for image interpretation education delivered via intensive and non-intensive formats. Further research, preferably randomised trials, investigating the effectiveness of intensive and non-intensive education formats of image interpretation education for radiographers is warranted.

  6. A survey of radiographers' confidence and self-perceived accuracy in frontline image interpretation and their continuing educational preferences

    International Nuclear Information System (INIS)

    Neep, Michael J; Steffens, Tom; Owen, Rebecca; McPhail, Steven M

    2014-01-01

    The provision of a written comment on traumatic abnormalities of the musculoskeletal system detected by radiographers can assist referrers and may improve patient management, but the practice has not been widely adopted outside the United Kingdom. The purpose of this study was to investigate Australian radiographers' perceptions of their readiness for practice in a radiographer commenting system and their educational preferences in relation to two different delivery formats of image interpretation education, intensive and non-intensive. A cross-sectional web-based questionnaire was implemented between August and September 2012. Participants included radiographers with experience working in emergency settings at four Australian metropolitan hospitals. Conventional descriptive statistics, frequency histograms, and thematic analysis were undertaken. A Wilcoxon signed-rank test examined whether a difference in preference ratings between intensive and non-intensive education delivery was evident. The questionnaire was completed by 73 radiographers (68% response rate). Radiographers reported higher confidence and self-perceived accuracy to detect traumatic abnormalities than to describe traumatic abnormalities of the musculoskeletal system. Radiographers frequently reported high desirability ratings for both the intensive and the non-intensive education delivery, no difference in desirability ratings for these two formats was evident (z = 1.66, P = 0.11). Some Australian radiographers perceive they are not ready to practise in a frontline radiographer commenting system. Overall, radiographers indicated mixed preferences for image interpretation education delivered via intensive and non-intensive formats. Further research, preferably randomised trials, investigating the effectiveness of intensive and non-intensive education formats of image interpretation education for radiographers is warranted

  7. Hydrodynamic states of phonons in insulators

    Directory of Open Access Journals (Sweden)

    S.A. Sokolovsky

    2012-12-01

    Full Text Available The Chapman-Enskog method is generalized for accounting the effect of kinetic modes on hydrodynamic evolution. Hydrodynamic states of phonon system of insulators have been studied in a small drift velocity approximation. For simplicity, the investigation was carried out for crystals of the cubic class symmetry. It has been found that in phonon hydrodynamics, local equilibrium is violated even in the approximation linear in velocity. This is due to the absence of phonon momentum conservation law that leads to a drift velocity relaxation. Phonon hydrodynamic equations which take dissipative processes into account have been obtained. The results were compared with the standard theory based on the local equilibrium validity. Integral equations have been obtained for calculating the objects of the theory (including viscosity and heat conductivity. It has been shown that in low temperature limit, these equations are solvable by iterations. Steady states of the system have been considered and an expression for steady state heat conductivity has been obtained. It coincides with the famous result by Akhiezer in the leading low temperature approximation. It has been established that temperature distribution in the steady state of insulator satisfies a condition of heat source absence.

  8. Hydrodynamic relaxations in dissipative particle dynamics

    Science.gov (United States)

    Hansen, J. S.; Greenfield, Michael L.; Dyre, Jeppe C.

    2018-01-01

    This paper studies the dynamics of relaxation phenomena in the standard dissipative particle dynamics (DPD) model [R. D. Groot and P. B. Warren, J. Chem. Phys. 107, 4423 (1997)]. Using fluctuating hydrodynamics as the framework of the investigation, we focus on the collective transverse and longitudinal dynamics. It is shown that classical hydrodynamic theory predicts the transverse dynamics at relatively low temperatures very well when compared to simulation data; however, the theory predictions are, on the same length scale, less accurate for higher temperatures. The agreement with hydrodynamics depends on the definition of the viscosity, and here we find that the transverse dynamics are independent of the dissipative and random shear force contributions to the stress. For high temperatures, the spectrum for the longitudinal dynamics is dominated by the Brillouin peak for large length scales and the relaxation is therefore governed by sound wave propagation and is athermal. This contrasts the results at lower temperatures and small length scale, where the thermal process is clearly present in the spectra. The DPD model, at least qualitatively, re-captures the underlying hydrodynamical mechanisms, and quantitative agreement is excellent at intermediate temperatures for the transverse dynamics.

  9. Hydrodynamic bearing lubricated with magnetic fluids

    International Nuclear Information System (INIS)

    Urreta, H; Leicht, Z; Sanchez, A; Agirre, A; Kuzhir, P; Magnac, G

    2009-01-01

    This paper summarizes the work carried out in the development of hydrodynamic lubricated journal bearings with magnetic fluids. Two different fluids have been analyzed, one ferrofluid from FERROTEC APG s10n and one magnetorheological fluid from LORD Corp., MRF122-2ED. Theoretical analysis has been carried out with numerical solutions of Reynolds equation, based on apparent viscosity modulation for ferrofluid and Bingham model for MR fluid. To validate this model, one test bench has been designed, manufactured and set up, where preliminary results shown in this paper demonstrate that magnetic fluids can be used to develop active journal bearings.

  10. Lung ultrasound as a diagnostic tool for radiographically-confirmed pneumonia in low resource settings.

    Science.gov (United States)

    Ellington, Laura E; Gilman, Robert H; Chavez, Miguel A; Pervaiz, Farhan; Marin-Concha, Julio; Compen-Chang, Patricia; Riedel, Stefan; Rodriguez, Shalim J; Gaydos, Charlotte; Hardick, Justin; Tielsch, James M; Steinhoff, Mark; Benson, Jane; May, Evelyn A; Figueroa-Quintanilla, Dante; Checkley, William

    2017-07-01

    Pneumonia is a leading cause of morbidity and mortality in children worldwide; however, its diagnosis can be challenging, especially in settings where skilled clinicians or standard imaging are unavailable. We sought to determine the diagnostic accuracy of lung ultrasound when compared to radiographically-confirmed clinical pediatric pneumonia. Between January 2012 and September 2013, we consecutively enrolled children aged 2-59 months with primary respiratory complaints at the outpatient clinics, emergency department, and inpatient wards of the Instituto Nacional de Salud del Niño in Lima, Peru. All participants underwent clinical evaluation by a pediatrician and lung ultrasonography by one of three general practitioners. We also consecutively enrolled children without respiratory symptoms. Children with respiratory symptoms had a chest radiograph. We obtained ancillary laboratory testing in a subset. Final clinical diagnoses included 453 children with pneumonia, 133 with asthma, 103 with bronchiolitis, and 143 with upper respiratory infections. In total, CXR confirmed the diagnosis in 191 (42%) of 453 children with clinical pneumonia. A consolidation on lung ultrasound, which is our primary endpoint for pneumonia, had a sensitivity of 88.5%, specificity of 100%, and an area under-the-curve of 0.94 (95% CI 0.92-0.97) when compared to radiographically-confirmed clinical pneumonia. When any abnormality on lung ultrasound was compared to radiographically-confirmed clinical pneumonia the sensitivity increased to 92.2% and the specificity decreased to 95.2%, with an area under-the-curve of 0.94 (95% CI 0.91-0.96). Lung ultrasound had high diagnostic accuracy for the diagnosis of radiographically-confirmed pneumonia. Added benefits of lung ultrasound include rapid testing and high inter-rater agreement. Lung ultrasound may serve as an alternative tool for the diagnosis of pediatric pneumonia. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights

  11. Commitment of the radiographer - does it matter to the patient?

    International Nuclear Information System (INIS)

    Blagoeva, D.; Shuleva, L.; Goudeva, V.; Stoinova, V.

    2015-01-01

    Full text: Radiographers are responsible for providing safe and accurate imaging examinations in a wide range of clinical environments, using a variety of imaging modalities and techniques so that appropriate management and treatment of patients and clients can proceed. The purpose of this presentation is to discuss: the responsibilities of radiographer in the clinical radiology department; their professional judgment to decide how to achieve a diagnostic outcome; the relationship patient/radiographer; the impact of the radiographer on patient care. Patient care and advocacy has always been an integral part of the radiography profession. The radiographer should respect the patient at all the times, be genuine in nature and empathies with the patient‘s condition. Good listening and observational skills are also very important components. The radiographers are personally accountable for their work and professional conduct

  12. Relabeling symmetries in hydrodynamics and magnetohydrodynamics

    International Nuclear Information System (INIS)

    Padhye, N.; Morrison, P.J.

    1996-04-01

    Lagrangian symmetries and concomitant generalized Bianchi identities associated with the relabeling of fluid elements are found for hydrodynamics and magnetohydrodynamics (MHD). In hydrodynamics relabeling results in Ertel's theorem of conservation of potential vorticity, while in MHD it yields the conservation of cross helicity. The symmetries of the reduction from Lagrangian (material) to Eulerian variables are used to construct the Casimir invariants of the Hamiltonian formalism

  13. Chest Radiographic Findings in Newly Diagnosed Pulmonary ...

    African Journals Online (AJOL)

    Five hundred newly diagnosed cases of Pulmonary Tuberculosis were treated with directly observed short-course treatment and 100 of them had chest radiographic examination done. The various chest radiographic patterns in the 100 subjects were studied and included: Fluffy exudative changes 80(80%), fibrosis 70(70%) ...

  14. Radiographic features of bisphosphonate therapy in pediatric patients

    Energy Technology Data Exchange (ETDEWEB)

    Grissom, L.E.; Theodore Harcke, H. [Dept. of Medical Imaging, Alfred I. duPont Hospital for Children, Nemours Children' s Clinic, Wilmington, DE (United States)

    2003-04-01

    Background: Pediatric patients are being treated with bisphosphonates for low bone mineral density. Skeletal radiographic findings have been described with bisphosphonates given orally and intravenously. Objective: To determine and describe the radiographic findings of cyclic intravenous bisphosphonate therapy in the growing skeleton. Materials and methods: Retrospective review of radiographs of 32 patients with osteogenesis imperfecta or cerebral palsy treated with intravenous bisphosphonates on a quarterly schedule. Results: Principal observations were metaphyseal bands and increased bone mineral density. The bands varied in spacing according to the age of the patient, rate of growth, and the location of the metaphysis. Fractures continued to be seen in patients with osteogenesis imperfecta. Conclusion: Cyclic bisphosphonate therapy results in distinctive radiographic findings in the growing skeleton. (orig.)

  15. Radiographic features of bisphosphonate therapy in pediatric patients

    International Nuclear Information System (INIS)

    Grissom, L.E.; Theodore Harcke, H.

    2003-01-01

    Background: Pediatric patients are being treated with bisphosphonates for low bone mineral density. Skeletal radiographic findings have been described with bisphosphonates given orally and intravenously. Objective: To determine and describe the radiographic findings of cyclic intravenous bisphosphonate therapy in the growing skeleton. Materials and methods: Retrospective review of radiographs of 32 patients with osteogenesis imperfecta or cerebral palsy treated with intravenous bisphosphonates on a quarterly schedule. Results: Principal observations were metaphyseal bands and increased bone mineral density. The bands varied in spacing according to the age of the patient, rate of growth, and the location of the metaphysis. Fractures continued to be seen in patients with osteogenesis imperfecta. Conclusion: Cyclic bisphosphonate therapy results in distinctive radiographic findings in the growing skeleton. (orig.)

  16. Impact analysis and testing of tritiated heavy water transportation packages including hydrodynamic effects

    International Nuclear Information System (INIS)

    Sauve, R.G.; Tulk, J.D.; Gavin, M.E.

    1989-01-01

    Ontario Hydro has recently designed a new Type B(M) Tritiated Heavy Water Transportation Package (THWTP) for the road transportation of tritiated heavy water from its operating nuclear stations to the Tritium Removal Facility in Ontario. These packages must demonstrate the ability to withstand severe shock and impact scenarios such as those prescribed by IAEA standards. The package, shown in figure 1, comprises an inner container filled with tritiated heavy water, and a 19 lb/ft 3 polyurethane foam-filled overpack. The overpack is of sandwich construction with 304L stainless steel liners and 10.5 inch thick nominal foam walls. The outer shell is 0.75 inch thick and the inner shell is 0.25 inch thick. The primary containment boundary consists of the overpack inner liner, the containment lid and outer containment seals in the lid region. The total weight of the container including the 12,000 lb. payload is 36,700 lb. The objective of the present study is to evaluate the hydrodynamic effect of the tritiated heavy water payload on the structural integrity of the THWTP during a flat end drop from a height of 9 m. The study consisted of three phases: (i) developing an analytical model to simulate the hydrodynamic effects of the heavy water payload during impact; (ii) performing an impact analysis for a 9 m flat end drop of the THWTP including fluid structure interaction; (iii) verification of the analytical models by experiment

  17. Digital radiographic evaluation of alveolar bone loss, density and lamina dura integrity on post splinting mandibular anterior with chronic periodontitis

    Science.gov (United States)

    Rafini, F.; Priaminiarti, M.; Sukardi, I.; Lessang, R.

    2017-08-01

    The healing of periodontal splinting can be detected both with clinical and radiographic examination. In this study, the alveolar bone was evaluated by radiographic digital periapical analysis. Periodontal tooth splinting is periodontal support therapy used to prevent periodontal injury during repair and regeneration of periodontal therapy. Radiographic digital periapical analysis of alveolar bone in the mandibular anterior region with chronic periodontitis and 2/3 cervical bone loss after three months of periodontal splinting. Eighty four proximal site (43 mesial and 41 distal) from 16 patients with chronic periodontitis and treated with spinting were examined by taking periapical digital radiographic at day 1 and 91. The bone loss, bone density and utility of lamina dura were evaluated. The statistical analysis after three months evaluation using T-test for bone loss, Wilcoxon sign rank test for bone density and utility lamina dura showed no significantly differences (pchronic periodontitis with 2/3 alveolar bone loss after three months splinting.

  18. [Comparison of dentomaxillary pantomography and periapical radiographs with horizontal tube shift in localizing the impacted teeth].

    Science.gov (United States)

    Wang, Sun; Fan, Lin-feng

    2005-04-01

    To compare the clinic value between dentomaxillary pantomography and periapical radiographs in localization of the impacted teeth. 43 impacted teeth were localized with both dentomaxillary pantomography technique and periapical radiographs with horizontal tube shift which is clinically widely used. And a comparison between the two methods was carried out using Chi square test. Both dentomaxillary pantomography and periapical radiographs with horizontal tube shift can relatively precisely demonstrate the position of the impacted teeth. The percentage of the cases which the image and the result of surgery was consistent in the two methods was 93.02% and 95.35% (P>0.05) respectively. There was no statistical difference between the two groups. Dentomaxillary pantomography can precisely localize the impacted teeth.

  19. Tooth coronal index: Key for age estimation on digital panoramic radiographs

    Directory of Open Access Journals (Sweden)

    Ravleen Nagi

    2018-01-01

    Full Text Available Background: Assessment of age through teeth is one of the most reliable and simple method than skeletal remains, to calculate age of an individual. Objectives: The study was carried out with an aim to evaluate reliability of dental age assessment through tooth coronal index (TCI method. Materials and Methods: The digital panoramic radiographs of 100 subjects of Chhattisgarh aged 20–70 years were selected for the study. The measurements were performed on the JPEG images of selected panoramic radiographs by using Adobe Acrobat 7.0 professional software. The height of the crown, i.e., coronal height, and the height of the coronal pulp cavity, i.e., coronal pulp cavity height, of mandibular second premolars and first molars were measured in millimeter (mm and then TCI was calculated for each tooth. Actual age of a subject was compared with TCI of tooth and the acquired data were subjected to Pearson's correlation and unpaired t-tests. Results: Negative correlation was observed between the real age and TCI of mandibular first molar (r = −0.092, P = 0.365 and second premolar (r = −0.168, P = 0.096. Statistically significant difference was observed between real age and TCI for mandibular second premolar and first molar (P = 0.000 by unpaired t-test. Conclusion: TCI has the potential to estimate age of an individual on dental radiographs. It is simple, cost effective than histological methods and can be applied to both living and unknown dead.

  20. An investigation of radiographers' mobile phone use and the success of an awareness campaign at reducing the nosocomial infection risks.

    Science.gov (United States)

    Crofton, C C; Foley, S J

    2018-02-01

    Mobile phone use by healthcare workers (HCWs) is widespread. Studies have shown that HCW's mobile phones can harbour pathogens associated with nosocomial infections. This study investigated whether an awareness campaign will result in an improvement in radiographers' phone and hand hygiene practices. Radiographers working in the general department of two university hospitals were invited to participate. One hospital was assigned as the experiment hospital and the other as a control. In the experiment hospital, adenosine triphosphate (ATP) testing of each participant's mobile phone determined the cleanliness of its surface. A corresponding survey was completed to determine their current practices and level of awareness. Subsequently, an infection control poster campaign took place for a one-month period, followed by re-testing. In the control hospital, the ATP testing and survey were also completed before and after a one-month period, but without a poster campaign. Radiographers were generally unaware of the infection risks associated with mobile phone use with 44% of all participants never cleaning their phone. The campaign successfully improved phone hygiene frequency and method in the experiment hospital. However, it did not improve hand hygiene practices and actual phone cleanliness (mean ATP count reductions of 10% (experiment hospital) and 20% (control)). The ATP testing as a less direct form of intervention showed similar levels of success in comparison to the poster campaign. A multifaceted educational approach is likely to be most effective in raising awareness and changing radiographers' phone and hand hygiene practices. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  1. Utilizing dimensional analysis with observed data to determine the significance of hydrodynamic solutions in coastal hydrology

    Science.gov (United States)

    Swain, Eric D.; Decker, Jeremy D.; Hughes, Joseph D.

    2014-01-01

    In this paper, the authors present an analysis of the magnitude of the temporal and spatial acceleration (inertial) terms in the surface-water flow equations and determine the conditions under which these inertial terms have sufficient magnitude to be required in the computations. Data from two South Florida field sites are examined and the relative magnitudes of temporal acceleration, spatial acceleration, and the gravity and friction terms are compared. Parameters are derived by using dimensionless numbers and applied to quantify the significance of the hydrodynamic effects. The time series of the ratio of the inertial and gravity terms from field sites are presented and compared with both a simplified indicator parameter and a more complex parameter called the Hydrodynamic Significance Number (HSN). Two test-case models were developed by using the SWIFT2D hydrodynamic simulator to examine flow behavior with and without the inertial terms and compute the HSN. The first model represented one of the previously-mentioned field sites during gate operations of a structure-managed coastal canal. The second model was a synthetic test case illustrating the drainage of water down a sloped surface from an initial stage while under constant flow. The analyses indicate that the times of substantial hydrodynamic effects are sporadic but significant. The simplified indicator parameter correlates much better with the hydrodynamic effect magnitude for a constant width channel such as Miami Canal than at the non-uniform North River. Higher HSN values indicate flow situations where the inertial terms are large and need to be taken into account.

  2. Mark III LOCA-related hydrodynamic load definition. Generic technical activity B-10. Final report

    International Nuclear Information System (INIS)

    Fields, M.B.; Kudrick, J.A.

    1984-08-01

    This report, prepared by the staff of the Office of Nuclear Reactor Regulation and its consultants at the Brookhaven National Laboratory, provides a discussion of LOCA-related suppression pool hydrodynamic loads in boiling water reactor (BWR) facilities with the Mark III pressure-suppression containment design. Its issuance completes NRC Generic Technical Activity B-10, Behavior of BWR Mark III Containment. On the basis of certain large-scale tests conducted between 1973 and 1979, the General Electric Company developed LOCA-related hydrodynamic load definitions for use in the design of the standard Mark III containment. The staff and its consultants have reviewed these load definitions and their bases and conclude that, with a few specified changes, the proposed load definitions provide conservative loading conditions. The staff approved acceptance criteria for LOCA-related hydrodynamic loads are provided in an appendix

  3. Retention of anatomy knowledge by student radiographers

    International Nuclear Information System (INIS)

    Hall, A. Susanne; Durward, Brian R.

    2009-01-01

    Introduction: Anatomy has long been regarded as an integral part of the core curriculum. However, anecdotal evidence suggests that long-term retention of anatomy knowledge may be deficient. This study aims to evidence whether student radiographers demonstrate the same level of knowledge of anatomy after a period of time has elapsed and to correlate to approaches to learning and studying. Methodology: A repeated measures design was utilised to measure retention of anatomy knowledge for both MCQs and short-response answers to a Practical Radiographic Anatomy Examination; alpha value p < 0.05. Fifty-one students from levels 2 and 3 were retested after a time lapse of 10 and 22 months respectively. The students were not aware that their knowledge was being retested. Approaches to learning and studying were measured using the ASSIST inventory. Results: Statistical analysis found no difference in performance on MCQ assessment, in either the combined sample or levels 2 and 3 separately, from baseline to retention occasions; average retention rate being 99%. However, a statistical difference in performance on PRAE assessment was found, with level 2 experiencing a larger reduction in scores; retention rate of 67% compared to level 3 at 77%. The students perceived themselves to be principally strategic in their approach to learning and studying but no strong relationships were found when correlated to test scores. Conclusion: The student radiographers in this study demonstrated varied anatomy retention rates dependent on assessment method employed and time interval that had elapsed. It is recommended that diverse teaching and assessment strategies are adopted to encourage a deeper approach to learning and studying.

  4. Reestablishment of radiographic kidney size in Miniature Schnauzer dogs.

    Science.gov (United States)

    Sohn, Jungmin; Yun, Sookyung; Lee, Jeosoon; Chang, Dongwoo; Choi, Mincheol; Yoon, Junghee

    2017-01-10

    Kidney size may be altered in renal diseases, and the detection of kidney size alteration has diagnostic and prognostic values. We hypothesized that radiographic kidney size, the kidney length to the second lumbar vertebra (L2) length ratio, in normal Miniature Schnauzer dogs may be overestimated due to their shorter vertebral length. This study was conducted to evaluate radiographic and ultrasonographic kidney size and L2 length in clinically normal Miniature Schnauzers and other dog breeds to evaluate the effect of vertebral length on radiographic kidney size and to reestablish radiographic kidney size in normal Miniature Schnauzers. Abdominal radiographs and ultrasonograms from 49 Miniature Schnauzers and 54 other breeds without clinical evidence of renal disease and lumbar vertebral abnormality were retrospectively evaluated. Radiographic kidney size, in the Miniature Schnauzer (3.31 ± 0.26) was significantly larger than that in other breeds (2.94 ± 0.27). Relative L2 length, the L2 length to width ratio, in the Miniature Schnauzer (1.11 ± 0.06) was significantly shorter than that in other breeds (1.21 ± 0.09). However, ultrasonographic kidney sizes, kidney length to aorta diameter ratios, were within or very close to normal range both in the Miniature Schnauzer (6.75 ± 0.67) and other breeds (7.16 ± 1.01). Thus, Miniature Schnauzer dogs have breed-specific short vertebrae and consequently a larger radiographic kidney size, which was greater than standard reference in normal adult dogs. Care should be taken when evaluating radiographic kidney size in Miniature Schnauzers to prevent falsely diagnosed renomegaly.

  5. Use of hydrodynamic cavitation in (waste)water treatment.

    Science.gov (United States)

    Dular, Matevž; Griessler-Bulc, Tjaša; Gutierrez-Aguirre, Ion; Heath, Ester; Kosjek, Tina; Krivograd Klemenčič, Aleksandra; Oder, Martina; Petkovšek, Martin; Rački, Nejc; Ravnikar, Maja; Šarc, Andrej; Širok, Brane; Zupanc, Mojca; Žitnik, Miha; Kompare, Boris

    2016-03-01

    The use of acoustic cavitation for water and wastewater treatment (cleaning) is a well known procedure. Yet, the use of hydrodynamic cavitation as a sole technique or in combination with other techniques such as ultrasound has only recently been suggested and employed. In the first part of this paper a general overview of techniques that employ hydrodynamic cavitation for cleaning of water and wastewater is presented. In the second part of the paper the focus is on our own most recent work using hydrodynamic cavitation for removal of pharmaceuticals (clofibric acid, ibuprofen, ketoprofen, naproxen, diclofenac, carbamazepine), toxic cyanobacteria (Microcystis aeruginosa), green microalgae (Chlorella vulgaris), bacteria (Legionella pneumophila) and viruses (Rotavirus) from water and wastewater. As will be shown, hydrodynamic cavitation, like acoustic, can manifest itself in many different forms each having its own distinctive properties and mechanisms. This was until now neglected, which eventually led to poor performance of the technique. We will show that a different type of hydrodynamic cavitation (different removal mechanism) is required for successful removal of different pollutants. The path to use hydrodynamic cavitation as a routine water cleaning method is still long, but recent results have already shown great potential for optimisation, which could lead to a low energy tool for water and wastewater cleaning. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Hydrodynamics of oceans and atmospheres

    CERN Document Server

    Eckart, Carl

    1960-01-01

    Hydrodynamics of Oceans and Atmospheres is a systematic account of the hydrodynamics of oceans and atmospheres. Topics covered range from the thermodynamic functions of an ideal gas and the thermodynamic coefficients for water to steady motions, the isothermal atmosphere, the thermocline, and the thermosphere. Perturbation equations, field equations, residual equations, and a general theory of rays are also presented. This book is comprised of 17 chapters and begins with an introduction to the basic equations and their solutions, with the aim of illustrating the laws of dynamics. The nonlinear

  7. Hydrodynamic simulation of elliptic flow

    CERN Document Server

    Kolb, P F; Ruuskanen, P V; Heinz, Ulrich W

    1999-01-01

    We use a hydrodynamic model to study the space-time evolution transverse to the beam direction in ultrarelativistic heavy-ion collisions with nonzero impact parameters. We focus on the influence of early pressure on the development of radial and elliptic flow. We show that at high energies elliptic flow is generated only during the initial stages of the expansion while radial flow continues to grow until freeze-out. Quantitative comparisons with SPS data from semiperipheral Pb+Pb collisions suggest the applicability of hydrodynamical concepts already $\\approx$ 1 fm/c after impact.

  8. The reliability of tablet computers in depicting maxillofacial radiographic landmarks

    Energy Technology Data Exchange (ETDEWEB)

    Tadinada, Aditya; Mahdian, Mina; Sheth, Sonam; Chandhoke, Taranpreet K.; Gopalakrishna, Aadarsh; Potluri, Anitha; Yadav, Sumit [University of Connecticut School of Dental Medicine, Farmington (United States)

    2015-09-15

    This study was performed to evaluate the reliability of the identification of anatomical landmarks in panoramic and lateral cephalometric radiographs on a standard medical grade picture archiving communication system (PACS) monitor and a tablet computer (iPad 5). A total of 1000 radiographs, including 500 panoramic and 500 lateral cephalometric radiographs, were retrieved from the de-identified dataset of the archive of the Section of Oral and Maxillofacial Radiology of the University Of Connecticut School Of Dental Medicine. Major radiographic anatomical landmarks were independently reviewed by two examiners on both displays. The examiners initially reviewed ten panoramic and ten lateral cephalometric radiographs using each imaging system, in order to verify interoperator agreement in landmark identification. The images were scored on a four-point scale reflecting the diagnostic image quality and exposure level of the images. Statistical analysis showed no significant difference between the two displays regarding the visibility and clarity of the landmarks in either the panoramic or cephalometric radiographs. Tablet computers can reliably show anatomical landmarks in panoramic and lateral cephalometric radiographs.

  9. Thermo-hydrodynamical modelling of a flooded deep mine reservoir - Case of the Lorraine Coal Basin

    International Nuclear Information System (INIS)

    Reichart, Guillaume

    2015-01-01

    Since 2006, cessation of dewatering in Lorraine Coal Basin (France) led to the flooding of abandoned mines, resulting in a new hydrodynamic balance in the area. Recent researches concerning geothermal exploitation of flooded reservoirs raised new questions, which we propose to answer. Our work aimed to understand the thermos-hydrodynamic behaviour of mine water in a flooding or flooded system. Firstly, we synthesized the geographical, geological and hydrogeological contexts of the Lorraine Coal Basin, and we chose a specific area for our studies. Secondly, temperature and electric conductivity log profiles were measured in old pits of the Lorraine Coal Basin, giving a better understanding of the water behaviour at a deep mine shaft scale. We were able to build a thermos-hydrodynamic model and simulate water behaviour at this scale. Flow regime stability is also studied. Thirdly, a hydrodynamic spatialized meshed model was realized to study the hydrodynamic behaviour of a mine reservoir as a whole. Observed water-table rise was correctly reproduced: moreover, the model can be used in a predictive way after the flooding. Several tools were tested, improved or developed to ease the study of flooded reservoirs, as three-dimensional up-scaling of hydraulic conductivities and a coupled spatialized meshed model with a pipe network. (author) [fr

  10. Radiographic evaluation of furcal perforations sealed with different materials in dogs' teeth

    Directory of Open Access Journals (Sweden)

    José Roberto Vanni

    2011-08-01

    Full Text Available OBJECTIVE: The objective of this work was to evaluate, using radiographic images, the behavior of four materials used to repair root perforations in dogs' teeth. Material and METHODS: Second and third premolars of 6 dogs were used. The 48 teeth were randomly divided into 4 groups (n=12 and the perforations were sealed with one of the following materials: MTA, AH Plus, Vitremer and gutta-percha. Dogs were submitted to general anesthesia, teeth were radiographed and pulp was accessed. Perforations were done, at the maximum curve of the pulp floor, sealed and the accessed coronal cavity was filled with glass ionomer cement (Vidrion R. After 90 days, the dogs were sacrificed and the last x-ray image was taken. Images were analyzed for the presence/absence of periodontal lesions at the perforation region. Data were analyzed statistically by chi-square test at 5% significance level. RESULTS: There were no statistically significant differences (p>0.05 among AH Plus, Vitremer and gutta-percha groups. MTA produced the smallest number of periodontal lesions (p<0.05. CONCLUSIONS: It may be concluded that none of the tested materials was able to preserve the integrity of the periodontal tissues in the furcation region, and the use of MTA resulted in the least formation of adjacent periodontal bone lesions revealed by the radiographic comparisons.

  11. Matching hand radiographs

    NARCIS (Netherlands)

    Kauffman, J.A.; Slump, Cornelis H.; Bernelot Moens, H.J.

    2005-01-01

    Biometric verification and identification methods of medical images can be used to find possible inconsistencies in patient records. Such methods may also be useful for forensic research. In this work we present a method for identifying patients by their hand radiographs. We use active appearance

  12. Effects of Different Viewing Conditions on Radiographic Interpretation

    Directory of Open Access Journals (Sweden)

    Mahkameh Moshfeghi

    2016-08-01

    Full Text Available Objectives: Optimum viewing conditions facilitate identification of radiographic details and decrease the need for retakes, patients’ costs and radiation dose. This study sought to evaluate the effects of different viewing conditions on radiographic interpretation.Materials and Methods: This diagnostic study was performed by evaluating radiograph of a 7mm-thick aluminum block, in which 10 holes with 2mm diameters were randomly drilled with depths ranging from 0.05 mm to 0.50mm. The radiograph was viewed by four oral radiologists independently under four viewing conditions, including a white light viewing light box in a lit room, yellow light viewing light box in a lit room, white light viewing light box in a dark room and yellow light viewing light box in a dark room. Number of circular shadows observed on the film was recorded. The data were analyzed by two-way ANOVA.Results: The mean number of detected circular shadows was 6.75, 7.5, 7.25 and 7.75 in white light viewing light box in a lit room, white light viewing light box in a dark room, yellow light viewing light box in a lit room and yellow light viewing light box in a dark room, respectively. Although the surrounding illumination had statistically significant effect on the radiographic details (P≤0.03, the light color of the viewing light box had no significant effect on visibility of the radiographic details.Conclusion: White and yellow light of the viewing light box had no significant effect on visibility of the radiographic details but more information was obtained in a dark room.

  13. Children’s pain and distress while undergoing an acute radiographic examination

    International Nuclear Information System (INIS)

    Björkman, B.; Nilsson, S.; Sigstedt, B.; Enskär, K.

    2012-01-01

    Pain has been highlighted as a main concern for children in conjunction with an acute radiographic examination. The aim of this study was to further investigate children’s pain and distress while undergoing an acute radiographic examination. The study comprised 29 participants with an age range of 5–15 years who were injured and submitted to an acute radiographic examination of the upper or lower extremity when the question at issue was fracture. The Coloured Analogue Scale (CAS) and the Facial Affective Scale (FAS) were used as self-reporting scales to measure the children’s pain and distress. The Face, Legs, Activity, Cry and Consolability Behavioural scale (FLACC) was used as an observation tool to assess behaviours associated with pain in children. Descriptive statistics were used when analysing the scores, and the results showed that children experience pain and distress in conjunction with a radiographic examination after an injury. Spearman’s correlation was used to compare variables, and significant correlations were obtained between the self-reported pain and the observed pain behaviour. Fischer’s Exact test was used to compare groups, and when using the cut-off 3.0 on the self-reporting scale no significant correlation was found concerning the pain reported by children diagnosed with and without a fracture. No significant correlations were found concerning the self-reported distress and pain either, regardless of whether it was a first-time visit and whether a parent was near during the examination.

  14. Can We Measure the Heel Bump? Radiographic Evaluation of Haglund's Deformity.

    Science.gov (United States)

    Bulstra, Gythe H; van Rheenen, Thijs A; Scholtes, Vanessa A B

    2015-01-01

    Haglund's deformity is a symptomatic posterosuperior deformity of the heel. The lateral radiograph of the ankle will show a prominent, large, posterosuperior part of the calcaneus, which can be measured using the Fowler and Philips angle (FPA, the angle between the posterior and plantar surface of the calcaneus) and the calcaneal pitch angle (CPA, the angle between the sole of the foot and the plantar part of the calcaneus). Although these angles are commonly used, these radiographic angle measurements have never shown a relationship with Haglund's deformity. In 78 patients (51% male) with symptomatic Haglund's deformity and a control group of 100 patients (41% male) with no heel complaints, we measured the FPA and CPA on weightbearing lateral radiographs of the foot. Using an unpaired t tests, no significant difference was found between the 2 groups in the FPA (p = .40). We measured a significant difference in the CPA between the Haglund group and the control group (p = .014). Subgroup analysis showed that this difference was mainly found in females (p verticalization of the calcaneus. This change in position results in extra traction on the Achilles tendon and can eventually cause tendinitis and bursitis. Radiographic measurement should be used as an auxiliary tool. If the calcaneus tends to change position, it would be interesting to understand this process, which could eventually lead to improvement in the treatment of Haglund's deformity. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  15. An audit of hip radiographs performed for general practitioners

    International Nuclear Information System (INIS)

    Bhatt, Raj; Rajesh, Arumugam; Morgan, Bruno; Finlay, David

    2001-01-01

    AIM: We carried out a prospective study of the GP referrals for hip radiographs to find out the proportion of radiographs falling within the RCR guidelines and to ascertain the reasons for not following the guidelines. MATERIALS AND METHODS: One thousand two hundred and fifty six consecutive hip radiographs were performed for GPs over a 12-month period. Questionnaires were sent to GPs for 873 referrals during an audit period of 18 months Four hundred and fifty three questionnaires were returned with adequate information. The proportion of change in management between the patients falling within the guidelines and those outside the guidelines was compared using Fisher's Exact Test (SPSS Package Version 9) and the corresponding 95% confidence interval (CI) was calculated. RESULTS: Only 194 (43%) of the 453 referrals were within RCR guidelines and 259 (57%) were outside guidelines. In the group where RCR guidelines were followed, 60% were normal, 34% had degenerative changes and 6% other diagnoses. The radiological reports changed management in 44%. In the group where guidelines were not followed 76% were normal, 18% had degenerative changes and 6% other diagnoses. The radiological reports changed management in 37%. There was no evidence of difference in the change in management between these two groups. Twenty per cent of the radiographs showed abnormalities other than hip changes. Of these, only 17% were abnormalities other than degenerative changes and considered significant. CONCLUSIONS: This audit does not reveal why the majority of the requests fell outside guidelines. This may be due to lack of awareness amongst GPs about guidelines, patient pressure, medico-legal problems and the need for reassurance. However, the audit does not show any evidence that following guidelines would increase efficiency of referral. Bhatt R. et al. (2001)

  16. Optimisation of the digital radiographic imaging of suspected non-accidental injury

    Science.gov (United States)

    Offiah, Amaka

    Aim: To optimise the digital (radiographic) imaging of children presenting with suspected non-accidental injury (NAI). Objectives: (i) To evaluate existing radiographic quality criteria, and to develop a more suitable system if these are found to be inapplicable to skeletal surveys obtained in suspected NAI. (ii) To document differences in image quality between conventional film-screen and the recently installed Fuji5000R computed radiography (CR) system at Great Ormond Street Hospital for Children, (iii) To document the extent of variability in the standard of skeletal surveys obtained in the UK for suspected NAI. (iv) To determine those radiographic parameters which yield the highest diagnostic accuracy, while still maintaining acceptable radiation dose to the child, (v) To determine how varying degrees of edge-enhancement affect diagnostic accuracy. (vi) To establish the accuracy of soft compared to hard copy interpretation of images in suspected NAI. Materials and Methods: (i) and (ii) Retrospective analysis of 286 paediatric lateral spine radiographs by two observers based on the Commission of European Communities (CEC) quality criteria, (iii) Review of the skeletal surveys of 50 consecutive infants referred from hospitals throughout the United Kingdom (UK) with suspected NAI. (iv) Phantom studies. Leeds TO. 10 and TO. 16 test objects were used to compare the relationship between film density, exposure parameters and visualisation of object details, (iv) Clinical study. Anteroposterior and lateral post mortem skull radiographs of six consecutive infants were obtained at various exposures. Six observers independently scored the images based on visualisation of five criteria, (v) and (vi) A study of diagnostic accuracy in which six observers independently interpreted 50 radiographs from printed copies (with varying degrees of edge-enhancement) and from a monitor. Results: The CEC criteria are useful for optimisation of imaging parameters and allow the detection

  17. Shear viscosity, cavitation and hydrodynamics at LHC

    International Nuclear Information System (INIS)

    Bhatt, Jitesh R.; Mishra, Hiranmaya; Sreekanth, V.

    2011-01-01

    We study evolution of quark-gluon matter in the ultrarelativistic heavy-ion collisions within the frame work of relativistic second-order viscous hydrodynamics. In particular, by using the various prescriptions of a temperature-dependent shear viscosity to the entropy ratio, we show that the hydrodynamic description of the relativistic fluid becomes invalid due to the phenomenon of cavitation. For most of the initial conditions relevant for LHC, the cavitation sets in very early stage. The cavitation in this case is entirely driven by the large values of shear viscosity. Moreover we also demonstrate that the conformal terms used in equations of the relativistic dissipative hydrodynamic can influence the cavitation time.

  18. The effects of second-order hydrodynamics on a semisubmersible floating offshore wind turbine

    International Nuclear Information System (INIS)

    Bayati, I; Jonkman, J; Robertson, A; Platt, A

    2014-01-01

    The objective of this paper is to assess the second-order hydrodynamic effects on a semisubmersible floating offshore wind turbine. Second-order hydrodynamics induce loads and motions at the sum- and difference-frequencies of the incident waves. These effects have often been ignored in offshore wind analysis, under the assumption that they are significantly smaller than first-order effects. The sum- and difference-frequency loads can, however, excite eigenfrequencies of a floating system, leading to large oscillations that strain the mooring system or vibrations that cause fatigue damage to the structure. Observations of supposed second-order responses in wave-tank tests performed by the DeepCwind consortium at the Maritime Research Institute Netherlands (MARIN) offshore basin suggest that these effects might be more important than originally expected. These observations inspired interest in investigating how second-order excitation affects floating offshore wind turbines and whether second-order hydrodynamics should be included in offshore wind simulation tools like FAST. In this work, the effects of second-order hydrodynamics on a floating semisubmersible offshore wind turbine are investigated. Because FAST is currently unable to account for second-order effects, a method to assess these effects was applied in which linearized properties of the floating wind system derived from FAST (including the 6x6 mass and stiffness matrices) are used by WAMIT to solve the first- and second-order hydrodynamics problems in the frequency domain. The method was applied to the Offshore Code Comparison Collaboration Continuation OC4-DeepCwind semisubmersible platform, supporting the National Renewable Energy Laboratory's 5-MW baseline wind turbine. In this paper, the loads and response of the system caused by the second-order hydrodynamics are analysed and compared to the first-order hydrodynamic loads and induced motions in the frequency domain. Further, the second

  19. Dental Radiographs Ordered by Dental Professionals: an ...

    African Journals Online (AJOL)

    Conclusions: Even in resource limited settings dental caries is still the regular indication for taking dental radiographs, and periapical views are the most frequent type of radiograph ordered. Maxillary central incisors and mandibular molars were types of teeth commonly x-rayed mainly due to the aesthetic importance of the ...

  20. Steady State Thermo-Hydrodynamic Analysis of Two-Axial groove and Multilobe Hydrodynamic Bearings

    Directory of Open Access Journals (Sweden)

    C. Bhagat

    2014-12-01

    Full Text Available Steady state thermo-hydrodynamic analysis of two axial groove and multi lobe oil journal bearings is performed in this paper. To study the steady state thermo-hydrodynamic characteristics Reynolds equation is solved simultaneously along with the energy equation and heat conduction equation in bush and shaft. The effect of groove geometry, cavitation in the fluid film, the recirculation of lubricant, shaft speed has also been taken into account. Film temperature in case of three-lobe bearing is found to be high as compared to other studied bearing configurations. The data obtained from this analysis can be used conveniently in the design of such bearings, which are presented in dimensionless form.

  1. Does radiographic arthrosis correlate with cartilage pathology in Labrador Retrievers affected by medial coronoid process disease?

    Science.gov (United States)

    Farrell, Michael; Heller, Jane; Solano, Miguel; Fitzpatrick, Noel; Sparrow, Tim; Kowaleski, Mike

    2014-02-01

    To compare radiographic elbow arthrosis with arthroscopic cartilage pathology in Labrador retrievers with elbow osteoarthritis secondary to medial coronoid process (MCP) disease. Retrospective epidemiological study. Labrador retrievers (n = 317; 592 elbow joints). Data were collected retrospectively (June 2007-June 2011) to identify Labrador retrievers with thoracic limb lameness and elbow pain, a complete set of elbow radiographs, and a comprehensive arthroscopic surgery report. Each radiograph was scored for osteophytosis on the anconeal process and ulnar subtrochlear sclerosis using a modification of the International Elbow Working Group (IEWG) scoring system. Elbows affected by traumatic MCP fracture, humeral condylar osteochondrosis, or ununited anconeal process were excluded. The arthroscopic report was used to generate a composite cartilage score (CCS; 0 = normal, 1 = mild, 2 = moderate, 3 = severe) for each elbow joint. Ordinal regression analysis was performed to test the relationship between radiographic arthrosis score and CCS. There was a significant relationship between radiographic elbow arthrosis and CCS (P arthrosis can be used to predict the severity of arthroscopic cartilage pathology in Labrador retrievers affected by MCP disease. © Copyright 2014 by The American College of Veterinary Surgeons.

  2. Radiographic Assessment of Dental Maturation in Children With Dental Agenesis.

    Science.gov (United States)

    Medina, Aida Carolina; Pozo, Rodrigo Del; de Cedres, Lucila Blanco

    Dental agenesis is the most common developmental anomaly in humans, frequently associated with disorders in dental development and maturation. The purpose of this study is to determine radiographic variations in dental maturation in a group of Venezuelan children with dental agenesis. 1,188 panoramic radiographs, from healthy patients ages 5 to 12 years old were studied for agenesis of permanent teeth. Dental maturation was assessed by relative eruption and dental age according to Nolla, comparing children affected with dental agenesis to a stratified control group selected from the same population, excluding children with premature loss of primary teeth in the left quadrants and unclear radiographs. Descriptive analysis, and differences between means and medians (Student t test, Kruskall-Wallis p=0.05) were performed. Medians for Nolla stages were similar between groups, with delay in tooth formation in the agenesis group for second molars (p<0.05) and maxillary lateral incisors and second premolars. Dental age was significantly underestimated for both groups, -0.89 (±0.78) for the control group and -1.20 (±0.95) for the study group. Tooth eruption was similar between groups. Dental age was significantly delayed in Venezuelan children with dental agenesis, with variable significance for tooth formation of studied teeth.

  3. Use your good judgement - Radiographers' knowledge in image production work

    International Nuclear Information System (INIS)

    Larsson, W.; Lundberg, N.; Hillergard, K.

    2009-01-01

    It has been shown that the demand for radiography services has markedly increased and radiographers' work has become more complex as their role has changed. More specifically, it entails new activities, new ways of communicating and new responsibilities. This means that radiographers work in new ways and need new ways to learn. The knowledge needed in this learning process is still unexplored. The aim of this study is to identify and present how radiographers use knowledge in image production work using PACS. This is explored by studying how radiographers use their knowledge in practice. The study adopts a qualitative approach, using participant observation of and semi-structured interviews with radiographers at five Swedish hospitals. To identify properties of knowledge, Blackler's theory of knowledge components was applied. The results of this study show that radiographers use the knowledge components in different situations in their image production work. They use embrained knowledge in planning X-ray examinations and in viewing images. Encoded knowledge is required for the use of various kinds of documentation, such as manuals and protocols. Embodied knowledge is action-oriented and involves 'gut feelings'. The study also illustrates that radiographers use their knowledge at different levels as routine actors or as reflective actors, in a more static way or with a flexible attitude, more unreflectively or more as critical reflectors, and finally more as performing automatic action or problem-solving action. This study concludes that radiographers need more reflective actors in the image production process when working with PACS. The study also illustrates that radiographers need to be flexible in their work; there is little room for static work. In work they need to analyze images, it is not enough to 'check them off'; they cannot just read documents, you need to interpret them to optimize work performance. Overall, radiographers need to have a critical and

  4. Microflow Cytometers with Integrated Hydrodynamic Focusing

    Directory of Open Access Journals (Sweden)

    Martin Schmidt

    2013-04-01

    Full Text Available This study demonstrates the suitability of microfluidic structures for high throughput blood cell analysis. The microfluidic chips exploit fully integrated hydrodynamic focusing based on two different concepts: Two-stage cascade focusing and spin focusing (vortex principle. The sample—A suspension of micro particles or blood cells—is injected into a sheath fluid streaming at a substantially higher flow rate, which assures positioning of the particles in the center of the flow channel. Particle velocities of a few m/s are achieved as required for high throughput blood cell analysis. The stability of hydrodynamic particle positioning was evaluated by measuring the pulse heights distributions of fluorescence signals from calibration beads. Quantitative assessment based on coefficient of variation for the fluorescence intensity distributions resulted in a value of about 3% determined for the micro-device exploiting cascade hydrodynamic focusing. For the spin focusing approach similar values were achieved for sample flow rates being 1.5 times lower. Our results indicate that the performances of both variants of hydrodynamic focusing suit for blood cell differentiation and counting. The potential of the micro flow cytometer is demonstrated by detecting immunologically labeled CD3 positive and CD4 positive T-lymphocytes in blood.

  5. Radiographic evaluation of coxofemoral joint laxity in dogs part II: Comparison of stress-radiographic positioning techniques in dogs with hip dysplasia

    International Nuclear Information System (INIS)

    Duangdaun Kaenkangploo; Phiwipha Kamonrat; Marissak Kalpravidh

    2002-01-01

    Two stress-radiographic positioning techniques for evaluation of coxofemoral joint laxity in dogs with hip dysplasia were compared with the standard technique. Forty, healthy, large breed dogs were divided into two groups of 20 dogs. Group 1 had normal hips. Group 2 were dogs with mild to moderated grade of hip dysplasia according to the Orthopedic Foundation for Animals (OFA) standard. Dogs were anesthetized and placed in dorsal recumbency before 3 radiographic techniques, standard hip-extended, 60 deg and 90 deg stress techniques, were taken. For the 60 deg stress technique, hind legs were extended in parallel to each other at 60 deg to the table top and femoral heads were manually pushed craniodorsally during exposure. For the 90 deg stress technique, femurs were positioned perpendicular to the table top, stifles were 90 deg flexed and adducted and femoral heads were manually pushed in a craniodorsal direction during exposure. Subluxation index (SI) and dorsolateral subluxation score (DLS score) of coxofemoral joints were assessed from radiographs. The SI of normal dogs from standard, 60 deg and 90 deg stress techniques were 0.15, 0.20 and 0.23 and of dysplastic dogs were 0.34, 0.40 and 0.41 respectively. The degress of subluxation assessed from the two stress technique radiographs were significantly greater (p0.05) than those shown on the standard technique radiographs in both groups of dogs. DLS scores of normal dogs from standard, 60 deg and 90 deg stress techniques were 65.1, 64.3 and 61.0 percent and of dysplastic dogs were 55.4, 53.6 and 47.6 percent respectively. Mean of DLS scores assessed from the 90 deg radiographs was significantly lower (p0.05) than those assessed from radiographs of other two teachniques in both groups of dogs. The findings suggested that the 90 deg stress technique is more efficient than the standard and 60 deg stress techniques for radiographic evaluation of coxofemoral joint laxity in dogs with mild hip dysplasia and early

  6. Design and evaluation of learning strategies for a group of radiographers in radiostereometric analysis (RSA)

    DEFF Research Database (Denmark)

    Muharemovic, O; Troelsen, A; Thomsen, M G

    2017-01-01

    INTRODUCTION: The purpose of this study was to design and evaluate a radiostereometric analysis (RSA) program aimed at radiographers in order to increase their cognitive and practical skills, thereby increasing image quality and minimizing exposure repetition. METHODS AND MATERIALS: Twenty...... radiographers were randomized into two identically sized study groups. Training consisted of a theoretical and practical workshop using a phantom. Tests were performed to compare the effect of training to nontraining, and the effect of time duration on the maintenance of RSA skills. The effect of training...... after training group B had experienced overall significant improvement on a par with group A. CONCLUSION: It is realistic to implement an RSA X-ray training program where radiographers significantly improve their theoretical and practical skills in centering the CP closer to the CCF, NB and RP...

  7. The oblique interface in the right cardiophrenic angle: chest radiographic-CT correlation

    International Nuclear Information System (INIS)

    Kim, Jeung Sook; Lee, Kyung Soo; Choo, Sung Wook; Choo, In Wook

    1996-01-01

    An oblique interface in the right cardiophrenic angle, extending superomedially from right retrocardiac or supradiaphragmatic region inferolaterally to peridiaphragmatic region, is occasionally observed on posteroanterior chest radiograph. The aim of this study was to evaluate the frequency of visualization of the interface on chest radiographs and to elucidate its nature on radiographic-CT correlation. Posteroanterior chest radiographs from 300 consecutive subjects were analyzed to evaluate the frequency and demographic data about an oblique interface in the right cardiophrenic angle. Thin-section CT scans(1-mm collimation and 5-mm intervals) were obtained from the subjects with positive interface on chest radiograph for assessment of the nature of the interface. The demographic data in the subjects with and without the interface were tested statistically to note any difference between two groups. Oblique interface in the right cardiophrenic angle was present in 29 subjects(9.7%) on chest radiograph. The age of the subjects with positive interface(13 men and 16 women) ranged from 19 to 70 years(mean±SD, 47±12.7 years) whereas the age of the subjects without the interface from 16 to 82 years (mean±SD, 50±9.1 years)(p>0.1). The body weight of the subjects with the interface ranged from 41 to 72 Kg(mean±SD, 60±8.0Kg) whereas the body weight of the subjects without the interface from 41 to 85Kg(mean±SD, 63±10.1Kg)(p>0.1). On CT scan, it was formed due to contact between the epipericardial fat and the right middle lobe of the lung in 27 subjects(93%) and between the inferior vena cava and the medial basal segment of the right lower lobe of the lung in two(7%). Oblique interface in the right cardiophrenic angle is occasionally visualized on chest radiograph. It is formed due to contact between the right middle lobe of the lung and pericardial fat in most cases. The frequency of visualization of the interface has no relationship to age and body weight of the

  8. Connection between hydrodynamic, water bag and Vlasov models

    International Nuclear Information System (INIS)

    Gros, M.; Bertrand, P.; Feix, M.R.

    1978-01-01

    The connection between hydrodynamic, water bag and Vlasov models is still under consideration with numerical experiments. For long wavelength, slightly non linear excitations and initial preparations such as the usual adiabatic invariant Pn -3 is space independent, the hydrodynamic model is equivalent to the water bag, and for long wavelengths a nice agreement is found with the full numerical solution of the Vlasov equation. For other initial conditions when the water bag cannot be defined, the hydrodynamic approach does not represent the correct behaviour. (author)

  9. Inducer Hydrodynamic Load Measurement Devices

    Science.gov (United States)

    Skelley, Stephen E.; Zoladz, Thomas F.

    2002-01-01

    Marshall Space Flight Center (MSFC) has demonstrated two measurement devices for sensing and resolving the hydrodynamic loads on fluid machinery. The first - a derivative of the six component wind tunnel balance - senses the forces and moments on the rotating device through a weakened shaft section instrumented with a series of strain gauges. This "rotating balance" was designed to directly measure the steady and unsteady hydrodynamic loads on an inducer, thereby defining both the amplitude and frequency content associated with operating in various cavitation modes. The second device - a high frequency response pressure transducer surface mounted on a rotating component - was merely an extension of existing technology for application in water. MSFC has recently completed experimental evaluations of both the rotating balance and surface-mount transducers in a water test loop. The measurement bandwidth of the rotating balance was severely limited by the relative flexibility of the device itself, resulting in an unexpectedly low structural bending mode and invalidating the higher frequency response data. Despite these limitations, measurements confirmed that the integrated loads on the four-bladed inducer respond to both cavitation intensity and cavitation phenomena. Likewise, the surface-mount pressure transducers were subjected to a range of temperatures and flow conditions in a non-rotating environment to record bias shifts and transfer functions between the transducers and a reference device. The pressure transducer static performance was within manufacturer's specifications and dynamic response accurately followed that of the reference.

  10. When disaster strikes; the role of the forensic radiographer

    International Nuclear Information System (INIS)

    Walsh, Mary; Reeves, Pauline; Scott, Susan

    2004-01-01

    Forensic radiography is a vital tool utilised in the many facets of Forensic Medicine. This paper investigates the role of the forensic radiographer in a mass disaster situation; it also explores the psychological impact of this type of work on radiographers. A literature review indicated that limited work had been documented on the role of the radiographer in mass disasters. This ultimately creates doubt about whether or not the radiographer is acknowledged for the vital role he/she plays and if proper provisions were in place to assess any emotional damage in the aftermath of an emotionally and physically straining situation. A qualitative method of research was used (semi-structured interviews) in order to elicit radiographers' feelings and perceptions. This method is best suited to this research topic because it is a delicate subject. Four interviews were carried out and the responses are presented in themes including emergency versus mass grave experiences (including issues of time and preparation). Other themes include the role of the radiographer and interaction with other members of the team, as well as a discussion of the aftermath of their experiences, including the feelings of pride experienced

  11. Methodology to evaluation of the density in radiographic image

    International Nuclear Information System (INIS)

    Louzada, M.J.Q.; Pela, C.A.; Belangero, W.D.; Santos-Pinto, R.

    1998-01-01

    This study was designed in order to optimize the optical densitometry technique in radiographic images by the setorization of the characteristic curves of the radiographic films. We used 24 radiographs of a stepped aluminium wedge that were taken without rigorous control development and manually revealed. The densitometric values of the steps images and its thickness, for each radiographic, was utilized to generate its particular mathematics expressions that represent its characteristic densitometric curves and then it were used for setorization. The densitometric values were obtained by a Macbeth TD528 densitometer. The study showed an optimization in the representation of the relationship between the optical density of the steps images of the wedge and its correspondent thickness, provided by the setorization, with mean square error around 10 -5 . This optimization will allow the use of this methodology in quantitative evaluations of bone mass, by radiographic images. (author)

  12. Radiographic anatomy of the medial coronoid process of dogs

    International Nuclear Information System (INIS)

    Miyabayashi, T.; Takiguchi, M.; Schrader, S.C.; Biller, D.S.

    1995-01-01

    Mediolateral, flexed mediolateral, mediocaudal-laterocranial 15 degrees oblique (extended and supinated mediolateral), and craniolateral-caudomedial 20 degrees to 30 degrees oblique radiographs of 16 elbow-joint specimens were produced to study the radiographic anatomy of the medial coronoid process. On the mediolateral view, the cranial point of the coronoid process was at the level of the distal one-third of the radial epiphysis. Degree of superimposition of the proximal radius and ulna determined how the medial coronoid process was projected on the radiographs. Mediocaudal-laterocranial oblique radiographs best showed the cranial outline of the medial coronoid process with moderate superimposition of the proximal radius and ulna

  13. GLOFRIM v1.0 - A globally applicable computational framework for integrated hydrological-hydrodynamic modelling

    Science.gov (United States)

    Hoch, Jannis M.; Neal, Jeffrey C.; Baart, Fedor; van Beek, Rens; Winsemius, Hessel C.; Bates, Paul D.; Bierkens, Marc F. P.

    2017-10-01

    We here present GLOFRIM, a globally applicable computational framework for integrated hydrological-hydrodynamic modelling. GLOFRIM facilitates spatially explicit coupling of hydrodynamic and hydrologic models and caters for an ensemble of models to be coupled. It currently encompasses the global hydrological model PCR-GLOBWB as well as the hydrodynamic models Delft3D Flexible Mesh (DFM; solving the full shallow-water equations and allowing for spatially flexible meshing) and LISFLOOD-FP (LFP; solving the local inertia equations and running on regular grids). The main advantages of the framework are its open and free access, its global applicability, its versatility, and its extensibility with other hydrological or hydrodynamic models. Before applying GLOFRIM to an actual test case, we benchmarked both DFM and LFP for a synthetic test case. Results show that for sub-critical flow conditions, discharge response to the same input signal is near-identical for both models, which agrees with previous studies. We subsequently applied the framework to the Amazon River basin to not only test the framework thoroughly, but also to perform a first-ever benchmark of flexible and regular grids on a large-scale. Both DFM and LFP produce comparable results in terms of simulated discharge with LFP exhibiting slightly higher accuracy as expressed by a Kling-Gupta efficiency of 0.82 compared to 0.76 for DFM. However, benchmarking inundation extent between DFM and LFP over the entire study area, a critical success index of 0.46 was obtained, indicating that the models disagree as often as they agree. Differences between models in both simulated discharge and inundation extent are to a large extent attributable to the gridding techniques employed. In fact, the results show that both the numerical scheme of the inundation model and the gridding technique can contribute to deviations in simulated inundation extent as we control for model forcing and boundary conditions. This study shows

  14. Hydrodynamic disperser

    Energy Technology Data Exchange (ETDEWEB)

    Bulatov, A.I.; Chernov, V.S.; Prokopov, L.I.; Proselkov, Yu.M.; Tikhonov, Yu.P.

    1980-01-15

    A hydrodynamic disperser is suggested which contains a housing, slit nozzles installed on a circular base arranged opposite from each other, resonators secured opposite the nozzle and outlet sleeve. In order to improve the effectiveness of dispersion by throttling the flow, each resonator is made in the form of a crimped plate with crimpings that decrease in height in a direction towards the nozzle.

  15. Optimizing radiation exposure for CT localizer radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Bohrer, Evelyn; Maeder, Ulf; Fiebich, Martin [Univ. of Applied Sciences, Giessen (Germany). Inst. of Medical Physics and Radiation Protection-IMPS; Schaefer, Stefan; Krombach, Gabriele A. [Univ. Hospital Giessen (Germany). Dept. of Radiology; Noel, Peter B. [Technische Univ. Muenchen (Germany). Dept. of Diagnostic and Interventional Radiology

    2017-08-01

    The trend towards submillisievert CT scans leads to a higher dose fraction of localizer radiographs in CT examinations. The already existing technical capabilities make dose optimization of localizer radiographs worthwhile. Modern CT scanners apply automatic exposure control (AEC) based on attenuation data in such a localizer. Therefore not only this aspect but also the detectability of anatomical landmarks in the localizer for the desired CT scan range adjustment needs to be considered. The effective dose of a head, chest, and abdomen-pelvis localizer radiograph with standard factory settings and user-optimized settings was determined using Monte Carlo simulations. CT examinations of an anthropomorphic phantom were performed using multiple sets of acquisition parameters for the localizer radiograph and the AEC for the subsequent helical CT scan. Anatomical landmarks were defined to assess the image quality of the localizer. CTDI{sub vol} and effective mAs per slice of the helical CT scan were recorded to examine the impact of localizer settings on a helical CT scan. The dose of the localizer radiograph could be decreased by more than 90% while the image quality remained sufficient when selecting the lowest available settings (80 kVp, 20 mA, pa tube position). The tube position during localizer acquisition had a greater impact on the AEC than the reduction of tube voltage and tube current. Except for the use of a pa tube position, all changes of acquisition parameters for the localizer resulted in a decreased total radiation exposure. A dose reduction of CT localizer radiograph is necessary and possible. In the examined CT system there was no negative impact on the modulated helical CT scan when the lowest tube voltage and tube current were used for the localizer.

  16. Transport coefficients in second-order non-conformal viscous hydrodynamics

    International Nuclear Information System (INIS)

    Ryblewski, Radoslaw

    2015-01-01

    Based on the exact solution of Boltzmann kinetic equation in the relaxation-time approximation, the precision of the two most recent formulations of relativistic second-order non-conformal viscous hydrodynamics (14-moment approximation and causal Chapman-Enskog method), standard Israel-Stewart theory, and anisotropic hydrodynamics framework, in the simple case of one-dimensional Bjorken expansion, is tested. It is demonstrated that the failure of Israel-Stewart theory in reproducing exact solutions of the Boltzmann kinetic equation occurs due to neglecting and/or choosing wrong forms of some of the second-order transport coefficients. In particular, the importance of shear-bulk couplings in the evolution equations for dissipative quantities is shown. One finds that, in the case of the bulk viscous pressure correction, such coupling terms are as important as the corresponding first-order Navier-Stokes term and must be included in order to obtain, at least qualitative, overall agreement with the kinetic theory. (paper)

  17. Radiographic assessment of venous catheter position in children: Value of the lateral view

    International Nuclear Information System (INIS)

    Stark, D.D.; Brasch, R.C.; Gooding, C.A.

    1984-01-01

    Frontal chest radiographs can be misleading in the evaluation of central venous catheter placement. Lateral chest radiographs were obtained, in addition to the standard frontal radiographs, in 25 young children. In five (20%) of the children, the catheters were found to be malpositioned, and the frontal radiograph showed evidence of the abnormality in all five. The lateral radiographs also showed evidence of the abnormality in all five children; however, in three of the five, the lateral radiographs provided additional, more specific, diagnostic information. The lateral chest radiographs also demonstrated satisfactory catheter positioning in three other children in whom the frontal radiographs suggested abnormal positioning. Accurate assessment of catheter position was possible in all patients using both frontal and lateral chest radiographs. Injection of contrast material was not necessary to locate malpositioned catheters. Lateral radiographs are recommended whenever an abnormal catheter position is suspected clinically or from findings on the routine frontal radiograph. (orig.)

  18. Coupling Hydrodynamic and Wave Propagation Codes for Modeling of Seismic Waves recorded at the SPE Test.

    Science.gov (United States)

    Larmat, C. S.; Rougier, E.; Delorey, A.; Steedman, D. W.; Bradley, C. R.

    2016-12-01

    The goal of the Source Physics Experiment (SPE) is to bring empirical and theoretical advances to the problem of detection and identification of underground nuclear explosions. For this, the SPE program includes a strong modeling effort based on first principles calculations with the challenge to capture both the source and near-source processes and those taking place later in time as seismic waves propagate within complex 3D geologic environments. In this paper, we report on results of modeling that uses hydrodynamic simulation codes (Abaqus and CASH) coupled with a 3D full waveform propagation code, SPECFEM3D. For modeling the near source region, we employ a fully-coupled Euler-Lagrange (CEL) modeling capability with a new continuum-based visco-plastic fracture model for simulation of damage processes, called AZ_Frac. These capabilities produce high-fidelity models of various factors believed to be key in the generation of seismic waves: the explosion dynamics, a weak grout-filled borehole, the surrounding jointed rock, and damage creation and deformations happening around the source and the free surface. SPECFEM3D, based on the Spectral Element Method (SEM) is a direct numerical method for full wave modeling with mathematical accuracy. The coupling interface consists of a series of grid points of the SEM mesh situated inside of the hydrodynamic code's domain. Displacement time series at these points are computed using output data from CASH or Abaqus (by interpolation if needed) and fed into the time marching scheme of SPECFEM3D. We will present validation tests with the Sharpe's model and comparisons of waveforms modeled with Rg waves (2-8Hz) that were recorded up to 2 km for SPE. We especially show effects of the local topography, velocity structure and spallation. Our models predict smaller amplitudes of Rg waves for the first five SPE shots compared to pure elastic models such as Denny &Johnson (1991).

  19. Hydrodynamic Limit of Multiple SLE

    Science.gov (United States)

    Hotta, Ikkei; Katori, Makoto

    2018-04-01

    Recently del Monaco and Schleißinger addressed an interesting problem whether one can take the limit of multiple Schramm-Loewner evolution (SLE) as the number of slits N goes to infinity. When the N slits grow from points on the real line R in a simultaneous way and go to infinity within the upper half plane H, an ordinary differential equation describing time evolution of the conformal map g_t(z) was derived in the N → ∞ limit, which is coupled with a complex Burgers equation in the inviscid limit. It is well known that the complex Burgers equation governs the hydrodynamic limit of the Dyson model defined on R studied in random matrix theory, and when all particles start from the origin, the solution of this Burgers equation is given by the Stieltjes transformation of the measure which follows a time-dependent version of Wigner's semicircle law. In the present paper, first we study the hydrodynamic limit of the multiple SLE in the case that all slits start from the origin. We show that the time-dependent version of Wigner's semicircle law determines the time evolution of the SLE hull, K_t \\subset H\\cup R, in this hydrodynamic limit. Next we consider the situation such that a half number of the slits start from a>0 and another half of slits start from -a exact solutions, we will discuss the universal long-term behavior of the multiple SLE and its hull K_t in the hydrodynamic limit.

  20. Endodontic radiography: who is reading the digital radiograph?

    Science.gov (United States)

    Tewary, Shalini; Luzzo, Joseph; Hartwell, Gary

    2011-07-01

    Digital radiographic imaging systems have undergone tremendous improvements since their introduction. Advantages of digital radiographs over conventional films include lower radiation doses compared with conventional films, instantaneous images, archiving and sharing images easily, and manipulation of several radiographic properties that might help in diagnosis. A total of 6 observers including 2 endodontic residents, 3 endodontists, and 1 oral radiologist evaluated 150 molar digital periapical radiographs to determine which of the following conditions existed: normal periapical tissue, widened periodontal ligament, or presence of periapical radiolucency. The evaluators had full control over the radiograph's parameters of the Planmeca Dimaxis software program. All images were viewed on the same computer monitor with ideal vie-wing conditions. The same 6 observers evaluated the same 150 digital images 3 months later. The data were analyzed to determine how well the evaluators agreed with each other (interobserver agreement) for 2 rounds of observations and with themselves (intraobserver agreement). Fleiss kappa statistical analysis was used to measure the level of agreement among multiple raters. The overall Fleiss kappa value for interobserver agreement for the first round of interpretation was 0.34 (P value for interobserver agreement for the second round of interpretation was 0.35 (P fair (0.2-0.4) agreement among the 6 raters at both observation periods. A weighted kappa analysis was used to determine intraobserver agreement, which showed on average a moderate agreement. The results indicate that the interpretation of a dental radiograph is subjective, irrespective of whether conventional or digital radiographs are used. The factors that appeared to have the most impact were the years of experience of the examiner and familiarity of the operator with a given digital system. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All

  1. Factors for lifelong job retention among Swiss radiographers

    International Nuclear Information System (INIS)

    Lehmann, P.; Meystre, N. Richli; Mamboury, N.

    2015-01-01

    In Switzerland, a shortage of radiographers in the three radiology domains, radio-diagnostic, radiotherapy and nuclear medicine, is supposed to increase in the upcoming years. As job satisfaction has been shown to contribute to workplace retention, one purpose of the study was to explore the relationship between workplace retention and duration in the profession with job satisfaction. The study was based on two surveys. The institutional survey was addressed to all chiefs of radiology units in hospitals and ambulatory institutes (340, response rate 48%). All radiographers were asked to complete the individual survey (3000, response rate 25%). Two thirds of radiographers had been employed for five or more years in the same workplace, and nearly half intended to stay for 10 more years. The professional lifespan of radiographers is estimated to be approximately 27 years. 75% expressed their satisfaction with key aspects of professional activity, including the content of the work, autonomy, technology and their relationships with professionals and patients. These factors were not linked to a particular workplace, but to the profession itself. The radiographers build their own propitious work environment, even if salary and recognition by physicians are contributing to their dissatisfaction. The retention in the profession, consolidated by a high level of satisfaction, is an essential feature for a workforce policy. However, active measures for reinforcing retention are still necessary when considering that a lifelong career needs challenges and rewards. Additionally, the retention rate does not provide a guarantee adequacy for the future projected needs in the profession. - Highlights: • Retention in the profession, with a high level of satisfaction, is a major point for a workforce policy. • Job satisfaction of radiographers is not linked to a particular workplace, but to the profession itself. • The professional lifespan of radiographers in Switzerland is

  2. Occupational kneeling and radiographic tibiofemoral and patellofemoral osteoarthritis

    DEFF Research Database (Denmark)

    Rytter, Søren; Egund, Niels; Jensen, Lilli Kirkeskov

    2009-01-01

    ABSTRACT: BACKGROUND: The objective of our study was to evaluate the association between occupational kneeling and compartment specific radiographic tibiofemoral (TF) and patellofemoral (PF) osteoarthritis (OA). METHODS: Questionnaire data and bilateral knee radiographs were obtained in 134 male...

  3. Digital image processing of mandibular trabeculae on radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Ogino, Toshi

    1987-06-01

    The present study was aimed to reveal the texture patterns of the radiographs of the mandibular trabeculae by digital image processing. The 32 cases of normal subjects and the 13 cases of patients with mandibular diseases of ameloblastoma, primordial cysts, squamous cell carcinoma and odontoma were analyzed by their intra-oral radiographs in the right premolar regions. The radiograms were digitized by the use of a drum scanner densitometry method. The input radiographic images were processed by a histogram equalization method. The result are as follows : First, the histogram equalization method enhances the image contrast of the textures. Second, the output images of the textures for normal mandible-trabeculae radiograms are of network pattern in nature. Third, the output images for the patients are characterized by the non-network pattern and replaced by the patterns of the fabric texture, intertwined plants (karakusa-pattern), scattered small masses and amorphous texture. Thus, these results indicates that the present digital image system is expected to be useful for revealing the texture patterns of the radiographs and in the future for the texture analysis of the clinical radiographs to obtain quantitative diagnostic findings.

  4. Application of Hydrodynamic Cavitation for Food and Bioprocessing

    Science.gov (United States)

    Gogate, Parag R.

    Hydrodynamic cavitation can be simply generated by the alterations in the flow field in high speed/high pressure devices and also by passage of the liquid through a constriction such as orifice plate, venturi, or throttling valve. Hydrodynamic cavitation results in the formation of local hot spots, release of highly reactive free radicals, and enhanced mass transfer rates due to turbulence generated as a result of liquid circulation currents. These conditions can be suitably applied for intensification of different bioprocessing applications in an energy-efficient manner as compared to conventionally used ultrasound-based reactors. The current chapter aims at highlighting different aspects related to hydrodynamic cavitation, including the theoretical aspects for optimization of operating parameters, reactor designs, and overview of applications relevant to food and bioprocessing. Some case studies highlighting the comparison of hydrodynamic cavitation and acoustic cavitation reactors will also be discussed.

  5. Understanding chest radiographic anatomy with MDCT reformations

    Energy Technology Data Exchange (ETDEWEB)

    Sussmann, A.R. [Department of Radiology, Thoracic Imaging, NYU Langone Medical Center, New York, NY (United States); Ko, J.P., E-mail: jane.ko@nyumc.or [Department of Radiology, Thoracic Imaging, NYU Langone Medical Center, New York, NY (United States)

    2010-02-15

    Chest radiograph interpretation requires an understanding of the mediastinal reflections and anatomical structures. Computed tomography (CT) improves the learning of three-dimensional (3D) anatomy, and more recently multidetector CT (MDCT) technology has enabled the creation of high-quality reformations in varying projections. Multiplanar reformations (MPRs) of varying thickness in the coronal and sagittal projections can be created for direct correlation with findings on frontal and lateral chest radiographs, respectively. MPRs enable simultaneous visualization of the craniocaudal extent of thoracic structures while providing the anatomic detail that has been previously illustrated using cadaveric specimens. Emphasis will be placed on improving knowledge of mediastinal anatomy and reflections including edges, lines, and stripes that are visible on chest radiographs.

  6. The interest of radiographical investigations of bone diseases in the selection of stallions [orthopedic lesions, abnormal radiographic findings, multivariate analysis

    International Nuclear Information System (INIS)

    Valette, J.P.; Touzot, G.; Denoix, J.M.

    1997-01-01

    Breeding of sport horses requires products with qualities for performance traits. The objectives of this study were to investigate the relation between radiographical examination and descendant of sires. Foots, fetlocks of both thoracic and pelvic limbs, carpus, tarsus and stifles were examined radiographically in 225 3-year old horses descent from 25 stallions. Data were analysed by multivariate analysis. Results indicate that descendant of a stallion presents the same abnormal radiographic findings. It is concluded that bone diseases are of great importance in breeding sport horses and that these abnormalities could have a genetic component [fr

  7. Comparison of three contrast radiographic techniques in the dog large intestine

    International Nuclear Information System (INIS)

    Vargas, L.; Thibaut, J.; Olhaberry, E.; Born, R.; Deppe, R.

    1994-01-01

    In order to compare three radiographic techniques -pneumocolon, barium enema and double contrast- in the large intestine of the dog, three radiographic series in ventrodorsal and right lateral projections were taken. Six healthy adult dogs of both sexes with an approximate weight between 5 to 10 kg were used. Three enemas were administered 24, 12 and 2 hrs. before the series of radiographs were taken. Then dogs were anaesthetized with sodium tiopental (20 mg/kg iv) and the contrast media were introduced. Pneumocolon was carried out in the first series introducing air (20 cc/kg) in the large intestine through a Foley rectal catheter. Radiographs were taken in both projections, after 5 and 15min. respectively. Barium enema was performed in the second series introducing barium sulfate (18%) in the large intestine through a Foley rectal catheter (25 cc/kg); 5 and 15 min. later, the radiographs were taken. In the third series -double contrast- the barium sulfate, which was obtained from each dog using a catheter, was substituted by a volume of air equal to that obtained from the contrast medium. Later the radiographs were taken in both projections. The radiographic plates of each series were analized comparing the characteristics of: radiographic density, outline and volume. With the pneumocolon barium enema and double contrast, the radiographic density was, in most cases, low, high and inter-mediate respectively. The radiographic outline was, in most cases, regular for the three techniques. Thee radiographic volume was similar in all of the series. From the results obtained, it is concluded that double contrast best outlines the intestinal mucosa and more information can be obtained from it [es

  8. Chest radiographic abnormalities in HIV-infected African children: a longitudinal study.

    Science.gov (United States)

    Pitcher, Richard D; Lombard, Carl J; Cotton, Mark F; Beningfield, Stephen J; Workman, Lesley; Zar, Heather J

    2015-09-01

    There is limited knowledge of chest radiographic abnormalities over time in HIV-infected children in resource-limited settings. To investigate the natural history of chest radiographic abnormalities in HIV-infected African children, and the impact of antiretroviral therapy (ART). Prospective longitudinal study of the association of chest radiographic findings with clinical and immunological parameters. Chest radiographs were performed at enrolment, 6-monthly, when initiating ART and if indicated clinically. Radiographic abnormalities were classified as normal, mild or moderate severity and considered persistent if present for 6 consecutive months or longer. An ordinal multiple logistic regression model assessed the association of enrolment and time-dependent variables with temporal radiographic findings. 258 children (median (IQR) age: 28 (13-51) months; median CD4+%: 21 (15-24)) were followed for a median of 24 (18-42) months. 70 (27%) were on ART at enrolment; 130 (50%) (median age: 33 (18-56) months) commenced ART during the study. 154 (60%) had persistent severe radiographic abnormalities, with median duration 18 (6-24) months. Among children on ART, 69% of radiographic changes across all 6-month transition periods were improvements, compared with 45% in those not on ART. Radiographic severity was associated with previous radiographic severity (OR=120.80; 95% CI 68.71 to 212.38), lack of ART (OR=1.72; 95% CI 1.29 to 2.27), enrolment age ART was beneficial, reducing the risk of radiographic deterioration or increasing the likelihood of radiological improvement. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  9. Study of the thermo-hydrodynamic phenomena in the nuclear core during reflood phase

    International Nuclear Information System (INIS)

    Murao, Yoshio

    1983-03-01

    This paper describes the development of the core thermo-hydrodynamic model on the reflood phenomena during a loss-of-coolant accident in a light water reactor. This model was developed based on the physical understanding in order to obtain the flexibility of application to safety analysis. For this purpose, the flow pattern was modeled and the fundamental equations were derived. The equations were used to know the suitable variables for assembling the thermo-hydrodynamic model of each flow regime in a reflood analysis code. Then the hydrodynamic models and the heat transfer models of all flow regimes and the quench model were derived. Some of them were newly developed. It was found that water accumulation above the quench front occurred in some cases, however the criteria was not clarified. One-dimensional forced-feed reflood tests were performed and the models were assessed and partly improved by using the data of the tests. The verified models were built in a one-dimensional reflood analysis code and totally assessed with the data of the test mentioned above. Except for the location just below a grid spacer and cases of high flooding rate, the calculational results indicated good comparison with the experimental results when the water accumulation was assumed above the quench front. Additionally the test data from the other test facility were used for the verification of the model. The results also showed good comparison with the experimental results. It was found that better comparisons were obtained when the water accumulation was not assumed above quench front. From these assessment of the model, it was found that the model derived here describes the over-all reflood phenomena, while it has to be partly improved and the water accumulation phenomena should be further investigated. (author)

  10. Model of Collective Fish Behavior with Hydrodynamic Interactions

    Science.gov (United States)

    Filella, Audrey; Nadal, François; Sire, Clément; Kanso, Eva; Eloy, Christophe

    2018-05-01

    Fish schooling is often modeled with self-propelled particles subject to phenomenological behavioral rules. Although fish are known to sense and exploit flow features, these models usually neglect hydrodynamics. Here, we propose a novel model that couples behavioral rules with far-field hydrodynamic interactions. We show that (1) a new "collective turning" phase emerges, (2) on average, individuals swim faster thanks to the fluid, and (3) the flow enhances behavioral noise. The results of this model suggest that hydrodynamic effects should be considered to fully understand the collective dynamics of fish.

  11. Anisotropic hydrodynamics: Motivation and methodology

    Energy Technology Data Exchange (ETDEWEB)

    Strickland, Michael

    2014-06-15

    In this proceedings contribution I review recent progress in our understanding of the bulk dynamics of relativistic systems that possess potentially large local rest frame momentum-space anisotropies. In order to deal with these momentum-space anisotropies, a reorganization of relativistic viscous hydrodynamics can be made around an anisotropic background, and the resulting dynamical framework has been dubbed “anisotropic hydrodynamics”. I also discuss expectations for the degree of momentum-space anisotropy of the quark–gluon plasma generated in relativistic heavy ion collisions at RHIC and LHC from second-order viscous hydrodynamics, strong-coupling approaches, and weak-coupling approaches.

  12. Hydrodynamics of quark-gluon plasmas

    International Nuclear Information System (INIS)

    Blaizot, J.P.

    1986-06-01

    This paper reviews some aspects of the hydrodynamics of quark-gluon plasmas. Various stages of ultra-relativistic heavy ion collisions are described. Several estimates of the maximum energy density expected to be achieved in these collisions are compared. Discontinuities which may be induced in the hydrodynamic flow by a phase transition are described and a convenient numerical method designed to deal with such discontinuous flows is briefly presented. Finally, the correlations between particle transverse momenta and multiplicities are analyzed and one discusses to which extent these correlations could signal the occurrence of a phase transition in heavy ion collisions

  13. Hydrodynamic constants from cosmic censorship

    International Nuclear Information System (INIS)

    Nakamura, Shin

    2008-01-01

    We study a gravity dual of Bjorken flow of N=4 SYM-theory plasma. We point out that the cosmic censorship hypothesis may explain why the regularity of the dual geometry constrains the hydrodynamic constants. We also investigate the apparent horizon of the dual geometry. We find that the dual geometry constructed on Fefferman-Graham (FG) coordinates is not appropriate for examination of the apparent horizon since the coordinates do not cover the trapped region. However, the preliminary analysis on FG coordinates suggests that the location of the apparent horizon is very sensitive to the hydrodynamic parameters. (author)

  14. Main factors of efficiency of automated radiographic complex

    International Nuclear Information System (INIS)

    Akopov, V.S.; Voronin, S.A.; Grachev, A.V.; Golenishchev, I.A.; Majorov, A.N.; Meshalkin, I.A.

    1978-01-01

    The amount of work providing an assessment of the efficiency of a complex for automatized radiographic control is considered. The technique involves four stages. An analysis was performed to ascertain the efficiency of control of flaw detectability with regard to each of the stages of radiographic control. The relationships used in determining control efficiency and cited in the paper serve as a foundation for optimizing the technical parameters of the devices of the automatized complex and for creating calculation methods for generalized assessments of the efficiency of radiographic control

  15. Relativistic (3+1) dimensional hydrodynamic simulations of compact interacting binary systems

    International Nuclear Information System (INIS)

    Mathews, G.J.; Evans, C.R.; Wilson, J.R.

    1986-09-01

    We discuss the development of a relativistic hydrodynamic code for describing the evolution of astrophysical systems in three spatial dimensions. The application of this code to several test problems is presented. Preliminary results from the simulation of the dynamics of accreting binary white dwarf and neutron star systems are discussed. 14 refs., 4 figs

  16. Dental radiographic units - radiation safety and patient doses

    International Nuclear Information System (INIS)

    Nagpal, J.S.; Varadharajan, Geetha

    2001-01-01

    Three models of dental radiographic machines have been examined for radiation safety. Using TL dosemeters, doses received by the patients at chest level and the gonads have been estimated. Care should be taken to shield gonads during dental radiographic examinations. (author)

  17. A survey of the radiographic cassettes disinfection of university hospitals in seoul

    International Nuclear Information System (INIS)

    Kweon, Dae Cheol; Park, Peom; Kim, Moon Sun; Kim, Dong Sung

    2001-01-01

    The purpose of this study is to prevent nosocomial infection in patients through contact of radiographic cassettes. Data were collected from radiographers working in 29 university hospitals in Seoul in February and March 2001. Radiographic cassettes were disinfected daily in 5 hospitals, weekly in 4 hospitals, monthly in 5 hospitals, bimonthly in 1 hospital and once every three months in another hospital. 12 other hospitals do not practice regular disinfections of radiographic cassettes. Gauze soaked in disinfectant solution is used in 7 hospitals while 11 hospitals used cotton and cloth soaked in disinfectant solution to clean the radiographic cassettes. 26 hospitals used 99% alcohol based disinfectant solutions while 3 hospitals used 75% alcohol based disinfectant, 26 hospitals use of intercourse cassettes outpatients and in patients. In 26 hospitals, all patients shared the same set of radiographic cassettes used in the hospitals, or in 26 hospitals, separate sets of radiographic cassettes are used for outpatients and inpatients. Separate sets of cassettes are used for ICU and inpatients in 6 others hospitals. 23 hospitals used the same sets of radiographic cassettes for all their patients. radiographic cassettes are cleaned in wash area in the study room of the radiographic department in 17 hospitals. 12 other hospitals do not have designated cleaning areas for the cassettes. All radiographers practiced hands washing with soap. All 29 hospitals surveyed have infection control committee. However, only 9 out of the 29 hospitals surveyed provided Infection · disinfections control education to radiographers. Only 3 hospitals have radiographers sitting in the infection control committee. Infection management education is conducted in 63 hospitals annually, twice a year in 1 hospital and once every 3 months in 2 hospitals

  18. Radiographic analysis of partial or total vertebral body resection

    International Nuclear Information System (INIS)

    Whitten, C.G.; Hammer, G.H.; El-Khoury, G.Y.; Hugus, J.; Weinstein, J.N.

    1991-01-01

    Partial and total vertebrectomies are used in the treatment of primary and metastatic neoplasms of the spine. Serial radiographic studies are crucial in the follow-up of patients with vertebrectomies. This paper presents 33 cases and illustrates radiographic examples of both successful and complicated vertebrectomies, including radiographic signs of local tumor recurrence, loosening, migration or fracture of the hardware or methylmethacrylate, bone graft failure, and progressive spinal instability

  19. Segmentation of lung fields using Chan-Vese active contour model in chest radiographs

    Science.gov (United States)

    Sohn, Kiwon

    2011-03-01

    A CAD tool for chest radiographs consists of several procedures and the very first step is segmentation of lung fields. We develop a novel methodology for segmentation of lung fields in chest radiographs that can satisfy the following two requirements. First, we aim to develop a segmentation method that does not need a training stage with manual estimation of anatomical features in a large training dataset of images. Secondly, for the ease of implementation, it is desirable to apply a well established model that is widely used for various image-partitioning practices. The Chan-Vese active contour model, which is based on Mumford-Shah functional in the level set framework, is applied for segmentation of lung fields. With the use of this model, segmentation of lung fields can be carried out without detailed prior knowledge on the radiographic anatomy of the chest, yet in some chest radiographs, the trachea regions are unfavorably segmented out in addition to the lung field contours. To eliminate artifacts from the trachea, we locate the upper end of the trachea, find a vertical center line of the trachea and delineate it, and then brighten the trachea region to make it less distinctive. The segmentation process is finalized by subsequent morphological operations. We randomly select 30 images from the Japanese Society of Radiological Technology image database to test the proposed methodology and the results are shown. We hope our segmentation technique can help to promote of CAD tools, especially for emerging chest radiographic imaging techniques such as dual energy radiography and chest tomosynthesis.

  20. Influence of Radiographic Positioning on Canine Sacroiliac and Lumbosacral Angle Measurements.

    Science.gov (United States)

    Jones, Susan; Savage, Mason; Naughton, Brian; Singh, Susheela; Robertson, Ian; Roe, Simon C; Marcellin-Little, Denis J; Mathews, Kyle G

    2018-01-01

     To evaluate the influence of radiographic malpositioning on canine sacroiliac and lumbosacral inclination angles.  Using canine cadavers, lateral pelvic radiographs were acquired with the radiographic beam in a neutral position and then rotated 5, 10 and 15° to mimic rotational malpositioning. The focal point of the beam was then focused over the abdomen and again over mid-diaphysis of the femur to mimic an abdominal or femoral radiographic study.  Five degrees of rotational malpositioning did not influence measurements of sacroiliac or lumbosacral inclination, but malpositioning by more than 5° led to a significant decrease in both sacroiliac and lumbosacral angles. Moving the focal point to the femur significantly decreased the measured lumbosacral angle. Abdominally centred radiographs had no effect on lumbosacral and sacroiliac angle measurements.  When evaluating canine lumbosacral and sacroiliac angles radiographically, pelvic rotation of more than 5° should be avoided as should the use of lateral radiographs centred over the femur. Schattauer GmbH Stuttgart.