  1. Evaluation of stray radiofrequency radiation emitted by electrosurgical devices

    International Nuclear Information System (INIS)

    De Marco, M; Maggi, S

    2006-01-01

    Electrosurgery refers to the passage of a high-frequency, high-voltage electrical current through the body to achieve the desired surgical effects. At the same time, these procedures are accompanied by a general increase of the electromagnetic field in an operating room that may expose both patients and personnel to relatively high levels of radiofrequency radiation. In the first part of this study, we have taken into account the radiation emitted by different monopolar electrosurgical devices, evaluating the electromagnetic field strength delivered by an electrosurgical handle and straying from units and other electrosurgical accessories. As a summary, in the worst case a surgeon's hands are exposed to a continuous and pulsed RF wave whose magnetic field strength is 0.75 A m -1 (E-field 400 V m -1 ). Occasionally stray radiation may exceed ICNIRP's occupational exposure guidelines, especially close to the patient return plate. In the second part of this paper, we have analysed areas of particular concern to prevent electromagnetic interference with some life-support devices (ventilators and electrocardiographic devices), which have failed to operate correctly. Most clinically relevant interference occurred when an electrosurgery device was used within 0.3 m of medical equipment. In the appendix, we suggest some practical recommendations intended to minimize the potential for electromagnetic hazards due to therapeutic application of RF energy

  2. Electromagnetic Radiofrequency Radiation Emitted from GSM Mobile Phones Decreases the Accuracy of Home Blood Glucose Monitors

    Science.gov (United States)

    Mortazavi, SMJ; Gholampour, M; Haghani, M; Mortazavi, G; Mortazavi, AR

    2014-01-01

    Mobile phones are two-way radios that emit electromagnetic radiation in microwave range. As the number of mobile phone users has reached 6 billion, the bioeffects of exposure to mobile phone radiation and mobile phone electromagnetic interference with electronic equipment have received more attention, globally. As self-monitoring of blood glucose can be a beneficial part of diabetes control, home blood glucose testing kits are very popular. The main goal of this study was to investigate if radiofrequency radiation emitted from a common GSM mobile phone can alter the accuracy of home blood glucose monitors. Forty five female nondiabetic students aged 17-20 years old participated in this study. For Control-EMF group (30 students), blood glucose concentration for each individual was measured in presence and absence of radiofrequency radiation emitted by a common GSM mobile phone (HTC touch, Diamond 2) while the phone was ringing. For Control- Repeat group (15 students), two repeated measurements were performed for each participant in the absence of electromagnetic fields. The magnitude of the changes between glucose levels in two repeated measurements (|ΔC|) in Control-Repeat group was 1.07 ± 0.88 mg/dl while this magnitude for Control-EMF group was 7.53 ± 4.76 mg/dl (P electromagnetic interference in home blood glucose monitors. It can be concluded that electromagnetic interference from mobile phones has an adverse effect on the accuracy of home blood glucose monitors. We suggest that mobile phones should be used at least 50 cm away from home blood glucose monitors. PMID:25505778

  3. Electromagnetic Radiofrequency Radiation Emitted from GSM Mobile Phones Decreases the Accuracy of Home Blood Glucose Monitors

    Directory of Open Access Journals (Sweden)

    SMJ Mortazavi

    2014-09-01

    Full Text Available Mobile phones are two-way radios that emit electromagnetic radiation in microwave range. As the number of mobile phone users has reached 6 billion, the bioeffects of exposure to mobile phone radiation and mobile phone electromagnetic interference with electronic equipment have received more attention, globally. As self-monitoring of blood glucose can be a beneficial part of diabetes control, home blood glucose testing kits are very popular. The main goal of this study was to investigate if radiofrequency radiation emitted from a common GSM mobile phone can alter the accuracy of home blood glucose monitors. Forty five female nondiabetic students aged 17-20 years old participated in this study. For Control-EMF group (30 students, blood glucose concentration for each individual was measured in presence and absence of radiofrequency radiation emitted by a common GSM mobile phone (HTC touch, Diamond 2 while the phone was ringing. For Control- Repeat group (15 students, two repeated measurements were performed for each participant in the absence of electromagnetic fields. The magnitude of the changes between glucose levels in two repeated measurements (ΔC in Control-Repeat group was 1.07 ± 0.88 mg/dl while this magnitude for Control-EMF group was 7.53 ± 4.76 mg/dl (P < 0.001, two-tailed test. To the best of our knowledge, this is the first study to assess the electromagnetic interference in home blood glucose monitors. It can be concluded that electromagnetic interference from mobile phones has an adverse effect on the accuracy of home blood glucose monitors. We suggest that mobile phones should be used at least 50 cm away from home blood glucose monitors.

  4. Male reproductive health under threat: Short term exposure to radiofrequency radiations emitted by common mobile jammers

    Directory of Open Access Journals (Sweden)

    SMJ Mortazavi

    2013-01-01

    Full Text Available Background: Modern life prompted man to increasingly generate, transmit and use electricity that leads to exposure to different levels of electromagnetic fields (EMFs. Substantial evidence indicates that exposure to common sources of EMF such as mobile phones, laptops or wireless internet-connected laptops decreases human semen quality. In some countries, mobile jammers are occasionally used in offices, shrines, conference rooms and cinemas to block the signal. Aims: To the best of our knowledge, this is the first study to investigate the effect of short term exposure of human sperm samples to radiofrequency (RF radiations emitted by common mobile jammers. Subjects and Methods: Fresh semen samples were collected by masturbation from 30 healthy donors who had referred to Infertility Treatment Center at the Mother and Child Hospital with their wives. Female problem was diagnosed as the reason for infertility in these couples. Statistical Analysis: T-test and analysis of variance were used to show statistical significance. Results: The motility of sperm samples exposed to jammer RF radiation for 2 or 4 h were significantly lower than those of sham-exposed samples. These findings lead us to the conclusion that mobile jammers may significantly decrease sperm motility and the couples′ chances of conception. Conclusion: Based on these results, it can be suggested that in countries that have not banned mobile jammer use, legislations should be urgently passed to restrict the use of these signal blocking devices in public or private places.

  5. Male reproductive health under threat: Short term exposure to radiofrequency radiations emitted by common mobile jammers

    Science.gov (United States)

    Mortazavi, SMJ; Parsanezhad, ME; Kazempour, M; Ghahramani, P; Mortazavi, AR; Davari, M

    2013-01-01

    BACKGROUND: Modern life prompted man to increasingly generate, transmit and use electricity that leads to exposure to different levels of electromagnetic fields (EMFs). Substantial evidence indicates that exposure to common sources of EMF such as mobile phones, laptops or wireless internet-connected laptops decreases human semen quality. In some countries, mobile jammers are occasionally used in offices, shrines, conference rooms and cinemas to block the signal. AIMS: To the best of our knowledge, this is the first study to investigate the effect of short term exposure of human sperm samples to radiofrequency (RF) radiations emitted by common mobile jammers. SUBJECTS AND METHODS: Fresh semen samples were collected by masturbation from 30 healthy donors who had referred to Infertility Treatment Center at the Mother and Child Hospital with their wives. Female problem was diagnosed as the reason for infertility in these couples. STATISTICAL ANALYSIS: T-test and analysis of variance were used to show statistical significance. RESULTS: The motility of sperm samples exposed to jammer RF radiation for 2 or 4 h were significantly lower than those of sham-exposed samples. These findings lead us to the conclusion that mobile jammers may significantly decrease sperm motility and the couples’ chances of conception. CONCLUSION: Based on these results, it can be suggested that in countries that have not banned mobile jammer use, legislations should be urgently passed to restrict the use of these signal blocking devices in public or private places. PMID:24082653

  6. Radiofrequency radiation

    International Nuclear Information System (INIS)

    Elder, J.A.; Czerski, P.A.; Stuchly, M.A.; Mild, K.H.; Sheppard, A.R.

    1989-01-01

    High-level radiofrequency radiation is a source of thermal energy that carries all of the known implications of heating for biological systems, including burns, temporary and permanent changes in reproduction, cataracts, and death. In general, no changes in chromosomes, DNA or the reproductive potential of animals exposed to RF radiation have been reported in the absence of significant rises in temperature, though there are limited data on DNA and chromosomal changes at non-thermal levels. Human data are currently limited and do not provide adequate information about the relationship between prolonged low-level RF radiation exposure and increased mortality or morbidity, including cancer incidence. In epidemiological studies and clinical reports of RF effects in man, the problems of quantification are numerous and include uncertainties about ''dose'', health effects, latent periods, dose-response relationships, and interactions with other physical or chemical agents. 228 refs, 6 figs, 2 tabs

  7. Exposure to Radiofrequency Radiation Emitted from Common Mobile Phone Jammers Alters the Pattern of Muscle Contractions: an Animal Model Study

    Directory of Open Access Journals (Sweden)

    Rafati A.

    2015-09-01

    Full Text Available Introduction: The rapid growth of wireless communication technologies has caused public concerns regarding the biological effects of electromagnetic radiations on human health. Some early reports indicated a wide variety of non-thermal effects of electromagnetic radiation on amphibians such as the alterations of the pattern of muscle extractions. This study is aimed at investigating the effects of exposure to radiofrequency (RF radiation emitted from mobile phone jammers on the pulse height of contractions, the time interval between two subsequent contractions and the latency period of frog’s isolated gastrocnemius muscle after stimulation with single square pulses of 1V (1 Hz. Materials and Methods: Frogs were kept in plastic containers in a room. Animals in the jammer group were exposed to radiofrequency (RF radiation emitted from a common Jammer at a distance of 1m from the jammer’s antenna for 2 hours while the control frogs were only sham exposed. Then animals were sacrificed and isolated gastrocnemius muscles were exposed to on/off jammer radiation for 3 subsequent 10 minute intervals. Isolated gastrocnemius muscles were attached to the force transducer with a string. Using a PowerLab device (26-T, the pattern of muscular contractions was monitored after applying single square pulses of 1V (1 Hz as stimuli. Results: The findings of this study showed that the pulse height of muscle contractions could not be affected by the exposure to electromagnetic fields. However, the latency period was effectively altered in RF-exposed samples. However, none of the experiments could show an alteration in the time interval between two subsequent contractions after exposure to electromagnetic fields. Conclusion: These findings support early reports which indicated a wide variety of non-thermal effects of electromagnetic radiation on amphibians including the effects on the pattern of muscle extractions.

  8. Exposure to Radiofrequency Radiation Emitted from Common Mobile Phone Jammers Alters the Pattern of Muscle Contractions: an Animal Model Study.

    Science.gov (United States)

    Rafati, A; Rahimi, S; Talebi, A; Soleimani, A; Haghani, M; Mortazavi, S M J

    2015-09-01

    The rapid growth of wireless communication technologies has caused public concerns regarding the biological effects of electromagnetic radiations on human health. Some early reports indicated a wide variety of non-thermal effects of electromagnetic radiation on amphibians such as the alterations of the pattern of muscle extractions. This study is aimed at investigating the effects of exposure to radiofrequency (RF) radiation emitted from mobile phone jammers on the pulse height of contractions, the time interval between two subsequent contractions and the latency period of frog's isolated gastrocnemius muscle after stimulation with single square pulses of 1V (1 Hz). Frogs were kept in plastic containers in a room. Animals in the jammer group were exposed to radiofrequency (RF) radiation emitted from a common Jammer at a distance of 1m from the jammer's antenna for 2 hours while the control frogs were only sham exposed. Then animals were sacrificed and isolated gastrocnemius muscles were exposed to on/off jammer radiation for 3 subsequent 10 minute intervals. Isolated gastrocnemius muscles were attached to the force transducer with a string. Using a PowerLab device (26-T), the pattern of muscular contractions was monitored after applying single square pulses of 1V (1 Hz) as stimuli. The findings of this study showed that the pulse height of muscle contractions could not be affected by the exposure to electromagnetic fields. However, the latency period was effectively altered in RF-exposed samples. However, none of the experiments could show an alteration in the time interval between two subsequent contractions after exposure to electromagnetic fields. These findings support early reports which indicated a wide variety of non-thermal effects of electromagnetic radiation on amphibians including the effects on the pattern of muscle extractions.

  9. Assessment of radiofrequency/microwave radiation emitted by the antennas of rooftop-mounted mobile phone base stations

    International Nuclear Information System (INIS)

    Keow, M. A.; Radiman, S.

    2006-01-01

    Radiofrequency (RF) and microwave (MW) radiation exposures from the antennas of rooftop-mounted mobile telephone base stations have become a serious issue in recent years due to the rapidly evolving technologies in wireless telecommunication systems. In Malaysia, thousands of mobile telephone base stations have been erected all over the country, most of which are mounted on the rooftops. In view of public concerns, measurements of the RF/MW levels emitted by the base stations were carried out in this study. The values were compared with the exposure limits set by several organisations and countries. Measurements were performed at 200 sites around 47 mobile phone base stations. It was found that the RF/MW radiation from these base stations were well below the maximum exposure limits set by various agencies. (authors)

  10. Effects of radiofrequency radiation emitted by cellular telephones on the cognitive functions of humans.

    Science.gov (United States)

    Eliyahu, Ilan; Luria, Roy; Hareuveny, Ronen; Margaliot, Menachem; Meiran, Nachshon; Shani, Gad

    2006-02-01

    The present study examined the effects of exposure to Electromagnetic Radiation emitted by a standard GSM phone at 890 MHz on human cognitive functions. This study attempted to establish a connection between the exposure of a specific area of the brain and the cognitive functions associated with that area. A total of 36 healthy right-handed male subjects performed four distinct cognitive tasks: spatial item recognition, verbal item recognition, and two spatial compatibility tasks. Tasks were chosen according to the brain side they are assumed to activate. All subjects performed the tasks under three exposure conditions: right side, left side, and sham exposure. The phones were controlled by a base station simulator and operated at their full power. We have recorded the reaction times (RTs) and accuracy of the responses. The experiments consisted of two sections, of 1 h each, with a 5 min break in between. The tasks and the exposure regimes were counterbalanced. The results indicated that the exposure of the left side of the brain slows down the left-hand response time, in the second-later-part of the experiment. This effect was apparent in three of the four tasks, and was highly significant in only one of the tests. The exposure intensity and its duration exceeded the common exposure of cellular phone users.

  11. Effect of Radiofrequency Radiation Emitted from 2G and 3G Cell Phone on Developing Liver of Chick Embryo - A Comparative Study.

    Science.gov (United States)

    D'Silva, Mary Hydrina; Swer, Rijied Thompson; Anbalagan, J; Rajesh, Bhargavan

    2017-07-01

    The increasing scientific evidence of various health hazards on exposure of Radiofrequency Radiation (RFR) emitted from both the cell phones and base stations have caused significant media attention and public discussion in recent years. The mechanism of interaction of RF fields with developing tissues of children and fetuses may be different from that of adults due to their smaller physical size and variation in tissue electromagnetic properties. The present study may provide an insight into the basic mechanisms by which RF fields interact with developing tissues in an embryo. To evaluate the possible tissue and DNA damage in developing liver of chick embryo following chronic exposure to Ultra-High Frequency/Radiofrequency Radiation (UHF/RFR) emitted from 2G and 3G cell phone. Fertilized chick embryos were incubated in four groups. Group A-experimental group exposed to 2G radiation (60 eggs), Group B- experimental group exposed to 3G radiation (60 eggs), Group C- sham exposed control group (60 eggs) and Group D- control group (48 eggs). On completion of scheduled duration, the embryos were collected and processed for routine histological studies to check structural changes in liver. The nuclear diameter and karyorrhexis changes of hepatocytes were analysed using oculometer and square reticule respectively. The liver procured from one batch of eggs from all the four groups was subjected to alkaline comet assay technique to assess DNA damage. The results were compared using one-way ANOVA test. In our study, the exposure of developing chick embryos to 2G and 3G cell phone radiations caused structural changes in liver in the form of dilated sinusoidal spaces with haemorrhage, increased vacuolations in cytoplasm, increased nuclear diameter and karyorrhexis and significantly increased DNA damage. The chronic exposure of chick embryo liver to RFR emitted from 2G and 3G cell phone resulted in various structural changes and DNA damage. The changes were more pronounced in 3

  12. Effect of Radiofrequency Radiation Emitted from 2G and 3G Cell Phone on Developing Liver of Chick Embryo – A Comparative Study

    Science.gov (United States)

    Swer, Rijied Thompson; Anbalagan, J.; Rajesh, Bhargavan

    2017-01-01

    Introduction The increasing scientific evidence of various health hazards on exposure of Radiofrequency Radiation (RFR) emitted from both the cell phones and base stations have caused significant media attention and public discussion in recent years. The mechanism of interaction of RF fields with developing tissues of children and fetuses may be different from that of adults due to their smaller physical size and variation in tissue electromagnetic properties. The present study may provide an insight into the basic mechanisms by which RF fields interact with developing tissues in an embryo. Aim To evaluate the possible tissue and DNA damage in developing liver of chick embryo following chronic exposure to Ultra-High Frequency/Radiofrequency Radiation (UHF/RFR) emitted from 2G and 3G cell phone. Materials and Methods Fertilized chick embryos were incubated in four groups. Group A-experimental group exposed to 2G radiation (60 eggs), Group B- experimental group exposed to 3G radiation (60 eggs), Group C- sham exposed control group (60 eggs) and Group D– control group (48 eggs). On completion of scheduled duration, the embryos were collected and processed for routine histological studies to check structural changes in liver. The nuclear diameter and karyorrhexis changes of hepatocytes were analysed using oculometer and square reticule respectively. The liver procured from one batch of eggs from all the four groups was subjected to alkaline comet assay technique to assess DNA damage. The results were compared using one-way ANOVA test. Results In our study, the exposure of developing chick embryos to 2G and 3G cell phone radiations caused structural changes in liver in the form of dilated sinusoidal spaces with haemorrhage, increased vacuolations in cytoplasm, increased nuclear diameter and karyorrhexis and significantly increased DNA damage. Conclusion The chronic exposure of chick embryo liver to RFR emitted from 2G and 3G cell phone resulted in various structural

  13. Survey of the Effects of Exposure to 900 MHz Radiofrequency Radiation Emitted by a GSM Mobile Phone on the Pattern of Muscle Contractions in an Animal Model

    Directory of Open Access Journals (Sweden)

    Mortazavi S. M. J.

    2015-09-01

    Full Text Available Background: The rapid development of wireless telecommunication technologies over the past decades, has led to significant changes in the exposure of the general public to electromagnetic fields. Nowadays, people are continuously exposed to different sources of electromagnetic fields such as mobile phones, mobile base stations, cordless phones, Wi-Fi routers, and power lines. Therefore, the last decade witnessed a rapidly growing concern about the possible health effects of exposure to electromagnetic fields emitted by these sources. Materials and Methods: In this study that was aimed at investigating the effects of exposure to radiofrequency (RF radiation emitted by a GSM mobile phone on the pattern of contraction in frog’s isolated gastrocnemius muscle after stimulation with single square pulses of 1V (1 Hz, pulse height of contractions, the time interval between two subsequent contractions and the latency period were measured. Results: Our findings showed that the pulse height of contractions muscle could be affected by the exposure to electromagnetic fields. Especially, the latency period was effectively altered in RF-exposed samples. However, none of the experiments could show an alteration in the time interval between two subsequent contractions after exposure to electromagnetic fields. Conclusion: These findings support early reports which indicated a wide variety of non-thermal effects of electromagnetic radiation on amphibians including the effects on the pattern of muscle extractions

  14. Survey of the Effects of Exposure to 900 MHz Radiofrequency Radiation Emitted by a GSM Mobile Phone on the Pattern of Muscle Contractions in an Animal Model.

    Science.gov (United States)

    Mortazavi, S M J; Rahimi, S; Talebi, A; Soleimani, A; Rafati, A

    2015-09-01

    The rapid development of wireless telecommunication technologies over the past decades, has led to significant changes in the exposure of the general public to electromagnetic fields. Nowadays, people are continuously exposed to different sources of electromagnetic fields such as mobile phones, mobile base stations, cordless phones, Wi-Fi routers, and power lines. Therefore, the last decade witnessed a rapidly growing concern about the possible health effects of exposure to electromagnetic fields emitted by these sources. In this study that was aimed at investigating the effects of exposure to radiofrequency (RF) radiation emitted by a GSM mobile phone on the pattern of contraction in frog's isolated gastrocnemius muscle after stimulation with single square pulses of 1V (1 Hz), pulse height of contractions, the time interval between two subsequent contractions and the latency period were measured. Our findings showed that the pulse height of contractions muscle could be affected by the exposure to electromagnetic fields. Especially, the latency period was effectively altered in RF-exposed samples. However, none of the experiments could show an alteration in the time interval between two subsequent contractions after exposure to electromagnetic fields. These findings support early reports which indicated a wide variety of non-thermal effects of electromagnetic radiation on amphibians including the effects on the pattern of muscle extractions.

  15. Radiation emitting devices act

    International Nuclear Information System (INIS)

    1970-01-01

    This Act, entitled the Radiation Emitting Devices Act, is concerned with the sale and importation of radiation emitting devices. Laws relating to the sale, lease or import, labelling, advertising, packaging, safety standards and inspection of these devices are listed as well as penalties for any person who is convicted of breaking these laws

  16. Radiation emitting devices regulations

    International Nuclear Information System (INIS)

    1970-01-01

    The Radiation Emitting Devices Regulations are the regulations referred to in the Radiation Emitting Devices Act and relate to the operation of devices. They include standards of design and construction, standards of functioning, warning symbol specifications in addition to information relating to the seizure and detention of machines failing to comply with the regulations. The radiation emitting devices consist of the following: television receivers, extra-oral dental x-ray equipment, microwave ovens, baggage inspection x-ray devices, demonstration--type gas discharge devices, photofluorographic x-ray equipment, laser scanners, demonstration lasers, low energy electron microscopes, high intensity mercury vapour discharge lamps, sunlamps, diagnostic x-ray equipment, ultrasound therapy devices, x-ray diffraction equipment, cabinet x-ray equipment and therapeutic x-ray equipment

  17. Evaluation of the Effect of Radiofrequency Radiation Emitted From Wi-Fi Router and Mobile Phone Simulator on the Antibacterial Susceptibility of Pathogenic Bacteria Listeria monocytogenes and Escherichia coli.

    Science.gov (United States)

    Taheri, M; Mortazavi, S M J; Moradi, M; Mansouri, S; Hatam, G R; Nouri, F

    2017-01-01

    Mobile phones and Wi-Fi radiofrequency radiation are among the main sources of the exposure of the general population to radiofrequency electromagnetic fields (RF-EMF). Previous studies have shown that exposure of microorganisms to RF-EMFs can be associated with a wide spectrum of changes ranged from the modified bacterial growth to the alterations of the pattern of antibiotic resistance. Our laboratory at the nonionizing department of the Ionizing and Non-ionizing Radiation Protection Research Center has performed experiments on the health effects of exposure to animal models and humans to different sources of electromagnetic fields such as cellular phones, mobile base stations, mobile phone jammers, laptop computers, radars, dentistry cavitrons, magnetic resonance imaging, and Helmholtz coils. On the other hand, we have previously studied different aspects of the challenging issue of the ionizing or nonionizing radiation-induced alterations in the susceptibility of microorganisms to antibiotics. In this study, we assessed if the exposure to 900 MHz GSM mobile phone radiation and 2.4 GHz radiofrequency radiation emitted from common Wi-Fi routers alters the susceptibility of microorganisms to different antibiotics. The pure cultures of Listeria monocytogenes and Escherichia coli were exposed to RF-EMFs generated either by a GSM 900 MHz mobile phone simulator and a common 2.4 GHz Wi-Fi router. It is also shown that exposure to RF-EMFs within a narrow level of irradiation (an exposure window) makes microorganisms resistant to antibiotics. This adaptive phenomenon and its potential threats to human health should be further investigated in future experiments. Altogether, the findings of this study showed that exposure to Wi-Fi and RF simulator radiation can significantly alter the inhibition zone diameters and growth rate for L monocytogenes and E coli. These findings may have implications for the management of serious infectious diseases.

  18. Tunable radiation emitting semiconductor device

    NARCIS (Netherlands)

    2009-01-01

    A tunable radiation emitting semiconductor device includes at least one elongated structure at least partially fabricated from one or more semiconductor materials exhibiting a bandgap characteristic including one or more energy transitions whose energies correspond to photon energies of light

  19. 47 CFR 1.1310 - Radiofrequency radiation exposure limits.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Radiofrequency radiation exposure limits. 1... Procedures Implementing the National Environmental Policy Act of 1969 § 1.1310 Radiofrequency radiation... exposure to radiofrequency (RF) radiation as specified in § 1.1307(b), except in the case of portable...

  20. Effects of 900 MHz radiofrequency radiation on skin hydroxyproline contents.

    Science.gov (United States)

    Çam, Semra Tepe; Seyhan, Nesrin; Kavaklı, Cengiz; Çelikbıçak, Ömür

    2014-09-01

    The present study aimed to investigate the possible effect of pulse-modulated radiofrequency radiation (RFR) on rat skin hydroxyproline content, since skin is the first target of external electromagnetic fields. Skin hydroxyproline content was measured using liquid chromatography mass spectrometer method. Two months old male wistar rats were exposed to a 900 MHz pulse-modulated RFR at an average whole body specific absorption rate (SAR) of 1.35 W/kg for 20 min/day for 3 weeks. The radiofrequency (RF) signals were pulse modulated by rectangular pulses with a repetition frequency of 217 Hz and a duty cycle of 1:8 (pulse width 0.576 ms). A skin biopsy was taken at the upper part of the abdominal costa after the exposure. The data indicated that whole body exposure to a pulse-modulated RF radiation that is similar to that emitted by the global system for mobile communications (GSM) mobile phones caused a statistically significant increase in the skin hydroxyproline level (p = 0.049, Mann-Whitney U test). Under our experimental conditions, at a SAR less than the International Commission on Non-Ionizing Radiation Protection safety limit recommendation, there was evidence that GSM signals could alter hydroxyproline concentration in the rat skin.

  1. Level of Radiofrequency (RF) Radiations from GSM Base Stations ...

    African Journals Online (AJOL)

    Levels of radiofrequency radiations around two global systems for mobile communication (GSM) base stations located in the vicinity of a residential quarter and workplace complex were measured. The effects of the radiofrequency radiations on albino mice placed in exposure cages and located around the base stations ...

  2. A Technical Approach to the Evaluation of Radiofrequency Radiation Emissions from Mobile Telephony Base Stations

    OpenAIRE

    Buckus, Raimondas; Struk?inskien?, Birute; Raistenskis, Juozas; Stukas, Rimantas; ?idlauskien?, Aurelija; ?erkauskien?, Rimant?; Isopescu, Dorina Nicolina; Stabryla, Jan; Cretescu, Igor

    2017-01-01

    During the last two decades, the number of macrocell mobile telephony base station antennas emitting radiofrequency (RF) electromagnetic radiation (EMR) in residential areas has increased significantly, and therefore much more attention is being paid to RF EMR and its effects on human health. Scientific field measurements of public exposure to RF EMR (specifically to radio frequency radiation) from macrocell mobile telephony base station antennas and RF electromagnetic field (EMF) intensity p...

  3. Radiofrequency radiation leakage from microwave ovens

    International Nuclear Information System (INIS)

    Lahham, A.; Sharabati, A.

    2013-01-01

    This work presents data on the amount of radiation leakage from 117 microwave ovens in domestic and restaurant use in the West Bank, Palestine. The study of leakage is based on the measurements of radiation emissions from the oven in real-life conditions by using a frequency selective field strength measuring system. The power density from individual ovens was measured at a distance of 1 m and at the height of centre of door screen. The tested ovens were of different types, models with operating powers between 1000 and 1600 W and ages ranging from 1 month to >20 y, including 16 ovens with unknown ages. The amount of radiation leakage at a distance of 1 m was found to vary from 0.43 to 16.4 μW cm -1 with an average value equalling 3.64 μW cm -2 . Leakages from all tested microwave ovens except for seven ovens (∼6 % of the total) were below 10 μW cm -2 . The highest radiation leakage from any tested oven was ∼16.4 μW cm -2 , and found in two cases only. In no case did the leakage exceed the limit of 1 μWcm -1 recommended by the ICNIRP for 2.45-GHz radiofrequency. This study confirms a linear correlation between the amount of leakage and both oven age and operating power, with a stronger dependence of leakage on age. (authors)

  4. Radiofrequency (RF) radiation measurement for diathermy machine

    International Nuclear Information System (INIS)

    Rozaimah Abdul Rahim; Roha Tukimin; Mohd Amirul Nizam; Ahmad Fadzli; Mohd Azizi

    2010-01-01

    Full-text: Diathermy machine is one of medical device that use widely in hospital and clinic. During the diathermy treatment, high radiofrequency (RF) currents (shortwave and microwave) are used to heat deep muscular tissues through electromagnetic energy to body tissues. The heat increases blood flow, relieve pain and speeding up recovery. The stray RF radiation from the machine can exposes to unintended tissue of the patient, to the operator (physical therapist) and also can cause electromagnetic interference (EMI) effect to medical devices around the machine. The main objective of this study is to establish a database of the RF radiation exposure levels experienced by the operator and patient during the treatments. RF radiation (electric and magnetic field) produced by the diathermy machines were measured using special RF survey meters. The finding of this study confirms that radiation levels on the surface and near the applicator of the diathermy machine much more elevated due to the much closer distance to the source and they exceeding the occupational and general public exposure limit. The results also shows the field strengths drop very significantly when the distance of measurement increase. (author)

  5. Administrative norms on radiofrequency radiation for occupationally exposed persons

    International Nuclear Information System (INIS)

    Saxeboel, G.

    1982-01-01

    The report presents a proposal for administrative norms on radiofrequency (RF) radiation for occupationally exposed persons. The norms establish maximum allowable field exposure in a frequency range from 1 MHz too 300 GHz. (RF)

  6. Eye examinations of laser and radiofrequency radiation workers

    International Nuclear Information System (INIS)

    Hocking, B.

    1988-01-01

    There are a growing number of uses of lasers and radiofrequency radiation in industry. Because these radiations may lead to various ocular effects, examinations of the eye are required for laser and radiofrequency workers as part of safe working practices. Various issues concerning these examinations are raised for discussion including: handling personal data, placement criteria, data collection, quality control, control data, the load on service providers, and costs

  7. Radiofrequency electromagnetic radiation from cell phone causes defective testicular function in male Wistar rats.

    Science.gov (United States)

    Oyewopo, A O; Olaniyi, S K; Oyewopo, C I; Jimoh, A T

    2017-12-01

    Cell phones have become an integral part of everyday life. As cell phone usage has become more widespread, concerns have increased regarding the harmful effects of radiofrequency electromagnetic radiation from these devices. The current study was undertaken to investigate the effects of the emitted radiation by cell phones on testicular histomorphometry and biochemical analyses. Adult male Wistar rats weighing 180-200 g were randomly allotted to control, group A (switched off mode exposure), group B (1-hr exposure), group C (2-hr exposure) and group D (3-hr exposure). The animals were exposed to radiofrequency electromagnetic radiation of cell phone for a period of 28 days. Histomorphometry, biochemical and histological investigations were carried out. The histomorphometric parameters showed no significant change (p electromagnetic radiation of cell phone leads to defective testicular function that is associated with increased oxidative stress and decreased gonadotropic hormonal profile. © 2017 Blackwell Verlag GmbH.

  8. Radiofrequency elektromagnetic radiation dynamics in vilnius city

    OpenAIRE

    Staniulytė, Justė

    2017-01-01

    Aim of the study – evaluate radio frequency electromagnetic radiation energy flux density emitted by Vilnius city base stations in the years 2009 – 2012 and compare results with the Republic of Lithuania hygiene standards HN 80:2011 and HN 80:2015 provisions. Study materials and method. In this paper the UAB (Ltd.)”Akustinių tyrimų centras” prepared measurement protocols of radio engineering objects in Vilnius city were used. Data analysis was performed using the statistical package ”R” 3.4.0...

  9. TU-H-BRA-01: The Physics of High Power Radiofrequency Isolation in a Novel Compact Linear Accelerator Based MRI Guided Radiation Therapy System

    Energy Technology Data Exchange (ETDEWEB)

    Lamb, J; Low, D [University of California, Los Angeles, Los Angeles, CA (United States); Mutic, S [Washington University School of Medicine, Saint Louis, MO (United States); Shvartsman, S; Chmielewski, T; Fought, G; Sharma, A; Dempsey, J [ViewRay, Inc., Oakwood Village, OH (United States)

    2016-06-15

    Purpose: To develop a method for isolating the radiofrequency waves emanating from linear accelerator components from the magnetic resonance imaging (MRI) system of an integrated MRI-linac. Methods: An MRI-guided radiation therapy system has been designed that integrates a linear accelerator with simultaneous MR imaging. The radiofrequency waves created by the accelerating process would degrade MR image quality, so a method for containing the radiofrequency waves and isolating the MR imager from them was developed. The linear accelerator radiofrequency modulator was placed outside the room, so a filter was designed to eliminate the radiofrequency corresponding to the proton Larmour frequency of 14.7 MHz. Placing the radiofrequency emitting components in a typical Faraday cage would have reduced the radiofrequency emissions, but the design would be susceptible to small gaps in the shield due to the efficiency of the Faraday cage reflecting internal radiofrequency emissions. To reduce internal radiofrequency reflections, the Faraday cage was lined with carbon fiber sheets. Carbon fiber has the property of attenuating the radiofrequency energy so that the overall radiofrequency field inside the Faraday cage is reduced, decreasing any radiofrequency energy emitted from small gaps in the cage walls. Results: Within a 1.2 MHz band centered on the Larmor frequency, the radiofrequency (RF) leakage from the Faraday cage was measured to be −90 dB with no RF on, −40 dB with the RF on and no shield, returning to −90 dB with the RF on and shields in place. The radiofrequency filter attenuated the linear accelerator modulator emissions in the 14.7 MHz band by 70 dB. Conclusions: One of the major challenges in designing a compact linear accelerator based MRI-guided radiation therapy system, that of isolating the high power RF system from the MRI, has been solved. The measured radiofrequency emissions are sufficiently small to enable system integration. This research was

  10. TU-H-BRA-01: The Physics of High Power Radiofrequency Isolation in a Novel Compact Linear Accelerator Based MRI Guided Radiation Therapy System

    International Nuclear Information System (INIS)

    Lamb, J; Low, D; Mutic, S; Shvartsman, S; Chmielewski, T; Fought, G; Sharma, A; Dempsey, J

    2016-01-01

    Purpose: To develop a method for isolating the radiofrequency waves emanating from linear accelerator components from the magnetic resonance imaging (MRI) system of an integrated MRI-linac. Methods: An MRI-guided radiation therapy system has been designed that integrates a linear accelerator with simultaneous MR imaging. The radiofrequency waves created by the accelerating process would degrade MR image quality, so a method for containing the radiofrequency waves and isolating the MR imager from them was developed. The linear accelerator radiofrequency modulator was placed outside the room, so a filter was designed to eliminate the radiofrequency corresponding to the proton Larmour frequency of 14.7 MHz. Placing the radiofrequency emitting components in a typical Faraday cage would have reduced the radiofrequency emissions, but the design would be susceptible to small gaps in the shield due to the efficiency of the Faraday cage reflecting internal radiofrequency emissions. To reduce internal radiofrequency reflections, the Faraday cage was lined with carbon fiber sheets. Carbon fiber has the property of attenuating the radiofrequency energy so that the overall radiofrequency field inside the Faraday cage is reduced, decreasing any radiofrequency energy emitted from small gaps in the cage walls. Results: Within a 1.2 MHz band centered on the Larmor frequency, the radiofrequency (RF) leakage from the Faraday cage was measured to be −90 dB with no RF on, −40 dB with the RF on and no shield, returning to −90 dB with the RF on and shields in place. The radiofrequency filter attenuated the linear accelerator modulator emissions in the 14.7 MHz band by 70 dB. Conclusions: One of the major challenges in designing a compact linear accelerator based MRI-guided radiation therapy system, that of isolating the high power RF system from the MRI, has been solved. The measured radiofrequency emissions are sufficiently small to enable system integration. This research was

  11. Radiation Emitting Product Corrective Actions and Recalls

    Data.gov (United States)

    U.S. Department of Health & Human Services — This database provides descriptions of radiation-emitting products that have been recalled under an approved corrective action plan to remove defective and...

  12. Radiation-emitting Electronic Product Codes

    Data.gov (United States)

    U.S. Department of Health & Human Services — This database contains product names and associated information developed by the Center for all products, both medical and non-medical, which emit radiation. It...

  13. 21 CFR 179.30 - Radiofrequency radiation for the heating of food, including microwave frequencies.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Radiofrequency radiation for the heating of food... PRODUCTION, PROCESSING AND HANDLING OF FOOD Radiation and Radiation Sources § 179.30 Radiofrequency radiation for the heating of food, including microwave frequencies. Radiofrequency radiation, including...

  14. Metallic implants and exposure to radiofrequency radiation

    International Nuclear Information System (INIS)

    Joyner, K.H.; Fleming, A.H.F.; MacFarlane, I.P.; Hocking, B.

    1988-01-01

    There is increasing use of radiofrequency radiation (RFR) in industry for communications, welding, security, radio, medicine, navigation etc. It has been recognised for some years that RFR may interact with cardiac pacemakers and steps have been taken to prevent this interference. It is less well recognised that other metallic implants may also act as antennas in an RFR field and possibly cause adverse health effects by heating local tissues. There are a large and increasing number of implants having metal components which may be found in RFR workers. These implants include artificial joints, rods and plates used in orthopaedics, rings in heart valves, wires in sutures, bionic ears, subcutaneous infusion systems and (external) transdermal drug delivery patches 1 . The physician concerned with job placement of such persons requires information on the likelihood of an implant interacting with RFR so as to impair health. The following outlines the approach developed in Telecom Australia, beginning with the general principles and then presenting a specific example discussion of a specific example

  15. Effects of radiofrequency exposure emitted from a GSM mobile phone on proliferation, differentiation, and apoptosis of neural stem cells

    Science.gov (United States)

    Eghlidospour, Mahsa; Ghanbari, Amir

    2017-01-01

    Due to the importance of neural stem cells (NSCs) in plasticity of the nervous system and treating neurodegenerative diseases, the main goal of this study was to evaluate the effects of radiofrequency radiation emitted from a GSM 900-MHz mobile phone with different exposure duration on proliferation, differentiation and apoptosis of adult murine NSCs in vitro. We used neurosphere assay to evaluate NSCs proliferation, and immunofluorescence assay of neural cell markers to examine NSCs differentiation. We also employed alamarBlue and caspase 3 apoptosis assays to assess harmful effects of mobile phone on NSCs. Our results showed that the number and size of resulting neurospheres and also the percentage of cells differentiated into neurons decreased significantly with increasing exposure duration to GSM 900-MHz radiofrequency (RF)-electromagnetic field (EMF). In contrast, exposure to GSM 900-MHz RF-EMF at different durations did not influence cell viability and apoptosis of NSCs and also their astrocytic differentiation. It is concluded that accumulating dose of GSM 900-MHz RF-EMF might have devastating effects on NSCs proliferation and neurogenesis requiring more causations in terms of using mobile devices. PMID:28713615

  16. Radiotelemetry and wildlife: Highlighting a gap in the knowledge on radiofrequency radiation effects

    International Nuclear Information System (INIS)

    Balmori, Alfonso

    2016-01-01

    Radio transmitters and associated devices may induce negative effects that can bias the results of ongoing research. The main documented effects of radio transmitters on animals include reduced survival, decreased productivity, changes in behaviour and movement patterns and a biased sex ratio. The only factors that have claimed responsibility for these possible damages are the weight of the radio transmitter and associated devices, and the attachment type. The electromagnetic radiation produced by radio transmitters has not been considered so far in research. There have been no studies evaluating the effects of non-ionising electromagnetic radiation (radiofrequency signals) necessary for tracking, although the problems found were significantly associated with the length of time that animals had been carrying their radio transmitters. Similar problems as those in radiotracked animals have been found in numerous studies with animals exposed to radiofrequency radiation for a sufficient amount of time. Laboratory scientists investigating the orientation of animals know they have to shield the place where experiments are performed to prevent interference from man-made radiation, as anthropogenic signals may distort the results. It is paradoxical that, at the same time, field scientists investigating the movements and other aspects of animal biology are providing animals with radio transmitters that emit the same type of radiation, since this may affect the results concerning their orientation and movement. This paper identifies gaps in the knowledge that should be investigated in-depth. The possibility that the radiofrequency radiation from radiotracking devices is responsible for the findings should be considered. Considering this factor may allow researchers to best understand the long-term effects found. - Highlights: • Radiotracking may induce negative effects that can bias the results. • Effects have been documented on survival, reproduction and behaviour.

  17. Radiotelemetry and wildlife: Highlighting a gap in the knowledge on radiofrequency radiation effects

    Energy Technology Data Exchange (ETDEWEB)

    Balmori, Alfonso, E-mail: balmaral@jcyl.es

    2016-02-01

    Radio transmitters and associated devices may induce negative effects that can bias the results of ongoing research. The main documented effects of radio transmitters on animals include reduced survival, decreased productivity, changes in behaviour and movement patterns and a biased sex ratio. The only factors that have claimed responsibility for these possible damages are the weight of the radio transmitter and associated devices, and the attachment type. The electromagnetic radiation produced by radio transmitters has not been considered so far in research. There have been no studies evaluating the effects of non-ionising electromagnetic radiation (radiofrequency signals) necessary for tracking, although the problems found were significantly associated with the length of time that animals had been carrying their radio transmitters. Similar problems as those in radiotracked animals have been found in numerous studies with animals exposed to radiofrequency radiation for a sufficient amount of time. Laboratory scientists investigating the orientation of animals know they have to shield the place where experiments are performed to prevent interference from man-made radiation, as anthropogenic signals may distort the results. It is paradoxical that, at the same time, field scientists investigating the movements and other aspects of animal biology are providing animals with radio transmitters that emit the same type of radiation, since this may affect the results concerning their orientation and movement. This paper identifies gaps in the knowledge that should be investigated in-depth. The possibility that the radiofrequency radiation from radiotracking devices is responsible for the findings should be considered. Considering this factor may allow researchers to best understand the long-term effects found. - Highlights: • Radiotracking may induce negative effects that can bias the results. • Effects have been documented on survival, reproduction and behaviour.

  18. The effects of radiofrequency electromagnetic radiation on sperm function.

    Science.gov (United States)

    Houston, B J; Nixon, B; King, B V; De Iuliis, G N; Aitken, R J

    2016-12-01

    Mobile phone usage has become an integral part of our lives. However, the effects of the radiofrequency electromagnetic radiation (RF-EMR) emitted by these devices on biological systems and specifically the reproductive systems are currently under active debate. A fundamental hindrance to the current debate is that there is no clear mechanism of how such non-ionising radiation influences biological systems. Therefore, we explored the documented impacts of RF-EMR on the male reproductive system and considered any common observations that could provide insights on a potential mechanism. Among a total of 27 studies investigating the effects of RF-EMR on the male reproductive system, negative consequences of exposure were reported in 21. Within these 21 studies, 11 of the 15 that investigated sperm motility reported significant declines, 7 of 7 that measured the production of reactive oxygen species (ROS) documented elevated levels and 4 of 5 studies that probed for DNA damage highlighted increased damage due to RF-EMR exposure. Associated with this, RF-EMR treatment reduced the antioxidant levels in 6 of 6 studies that discussed this phenomenon, whereas consequences of RF-EMR were successfully ameliorated with the supplementation of antioxidants in all 3 studies that carried out these experiments. In light of this, we envisage a two-step mechanism whereby RF-EMR is able to induce mitochondrial dysfunction leading to elevated ROS production. A continued focus on research, which aims to shed light on the biological effects of RF-EMR will allow us to test and assess this proposed mechanism in a variety of cell types. © 2016 Society for Reproduction and Fertility.

  19. Looking at the other side of the coin: the search for possible biopositive cognitive effects of the exposure to 900 MHz GSM mobile phone radiofrequency radiation.

    Science.gov (United States)

    Mortazavi, Seyed Ali Reza; Tavakkoli-Golpayegani, Ali; Haghani, Masoud; Mortazavi, Seyed Mohammad Javad

    2014-01-01

    Although exposure to electromagnetic radiation in radiofrequency range has caused a great deal of concern globally, radiofrequency radiation has many critical applications in both telecommunication and non-communication fields. The induction of adaptive response phenomena by exposure to radiofrequency radiation as either increased resistance to a subsequent dose of ionizing radiation or resistance to a bacterial infection has been reported recently. Interestingly, the potential beneficial effects of mobile phone radiofrequency radiation are not only limited to the induction of adaptive phenomena. It has previously been indicated that the visual reaction time of university students significantly decreased after a 10 min exposure to radiofrequency radiation emitted by a mobile phone. Furthermore, it has been revealed that occupational exposures to radar radiations decreased the reaction time in radar workers. Based on these findings, it can be hypothesized that in special circumstances, these exposures might lead to a better response of humans to different hazards. Other investigators have also provided evidence that confirms the induction of RF-induced cognitive benefits. Furthermore, some recent reports have indicated that RF radiation may play a role in protecting against cognitive impairment in Alzheimer's disease. In this light, a challenging issue will arise if there are other RF-induced stimulating effects. It is also challenging to explore the potential applications of these effects. Further research may shed light on dark areas of the health effects of short and long-term human exposure to radiofrequency radiation.

  20. Measuring Radiofrequency and Microwave Radiation from Varying Signal Strengths

    Science.gov (United States)

    Davis, Bette; Gaul, W. C.

    2007-01-01

    This viewgraph presentation discusses the process of measuring radiofrequency and microwave radiation from various signal strengths. The topics include: 1) Limits and Guidelines; 2) Typical Variable Standard (IEEE) Frequency Dependent; 3) FCC Standard 47 CFR 1.1310; 4) Compliance Follows Unity Rule; 5) Multiple Sources Contribute; 6) Types of RF Signals; 7) Interfering Radiations; 8) Different Frequencies Different Powers; 9) Power Summing - Peak Power; 10) Contribution from Various Single Sources; 11) Total Power from Multiple Sources; 12) Are You Out of Compliance?; and 13) In Compliance.

  1. Measurement uncertainty in broadband radiofrequency radiation level measurements

    Directory of Open Access Journals (Sweden)

    Vulević Branislav D.

    2014-01-01

    Full Text Available For the evaluation of measurement uncertainty in the measurement of broadband radio frequency radiation, in this paper we propose a new approach based on the experience of the authors of the paper with measurements of radiofrequency electric field levels conducted in residential areas of Belgrade and over 35 municipalities in Serbia. The main objective of the paper is to present practical solutions in the evaluation of broadband measurement uncertainty for the in-situ RF radiation levels. [Projekat Ministarstva nauke Republike Srbije, br. III43009

  2. Acute effects of radiofrequency electromagnetic field emitted by mobile phone on brain function.

    Science.gov (United States)

    Zhang, Jun; Sumich, Alexander; Wang, Grace Y

    2017-07-01

    Due to its attributes, characteristics, and technological resources, the mobile phone (MP) has become one of the most commonly used communication devices. Historically, ample evidence has ruled out the substantial short-term impact of radiofrequency electromagnetic field (RF-EMF) emitted by MP on human cognitive performance. However, more recent evidence suggests potential harmful effects associated with MP EMF exposure. The aim of this review is to readdress the question of whether the effect of MP EMF exposure on brain function should be reopened. We strengthen our argument focusing on recent neuroimaging and electroencephalography studies, in order to present a more specific analysis of effects of MP EMF exposure on neurocognitive function. Several studies indicate an increase in cortical excitability and/or efficiency with EMF exposure, which appears to be more prominent in fronto-temporal regions and has been associated with faster reaction time. Cortical excitability might also underpin disruption to sleep. However, several inconsistent findings exist, and conclusions regarding adverse effects of EMF exposure are currently limited. It also should be noted that the crucial scientific question of the effect of longer-term MP EMF exposure on brain function remains unanswered and essentially unaddressed. Bioelectromagnetics. 38:329-338, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  3. Risk assessment and management of radiofrequency radiation exposure

    Energy Technology Data Exchange (ETDEWEB)

    Dabala, Dana [Railways Medical Clinic Cluj-Napoca, Occupational Medicine Department, 16-20 Bilascu Gheorghe St., 400015 Cluj-Napoca (Romania); Surducan, Emanoil; Surducan, Vasile; Neamtu, Camelia [National Institute for Research and Development of Isotopic and Molecular Technologies, 65-103 Donath St., 400293 Cluj-Napoca (Romania)

    2013-11-13

    Radiofrequency radiation (RFR) industry managers, occupational physicians, security department, and other practitioners must be advised on the basic of biophysics and the health effects of RF electromagnetic fields so as to guide the management of exposure. Information on biophysics of RFR and biological/heath effects is derived from standard texts, literature and clinical experiences. Emergency treatment and ongoing care is outlined, with clinical approach integrating the circumstances of exposure and the patient's symptoms. Experimental risk assessment model in RFR chronic exposure is proposed. Planning for assessment and monitoring exposure, ongoing care, safety measures and work protection are outlining the proper management.

  4. Risk assessment and management of radiofrequency radiation exposure

    International Nuclear Information System (INIS)

    Dabala, Dana; Surducan, Emanoil; Surducan, Vasile; Neamtu, Camelia

    2013-01-01

    Radiofrequency radiation (RFR) industry managers, occupational physicians, security department, and other practitioners must be advised on the basic of biophysics and the health effects of RF electromagnetic fields so as to guide the management of exposure. Information on biophysics of RFR and biological/heath effects is derived from standard texts, literature and clinical experiences. Emergency treatment and ongoing care is outlined, with clinical approach integrating the circumstances of exposure and the patient's symptoms. Experimental risk assessment model in RFR chronic exposure is proposed. Planning for assessment and monitoring exposure, ongoing care, safety measures and work protection are outlining the proper management

  5. CASPER: Concordia Atmospheric SPectroscopy of Emitted Radiation

    Science.gov (United States)

    de Petris, M.; Catalano, A.; de Gregori, S.; Lamagna, L.; Lattanzi, V.; Luzzi, G.; Maoli, R.; Melchiorri, A.; Melchiorri, F.; Savini, G.; Vetrani, G. G.; Battistelli, E. S.; Valenziano, L.; Mandolesi, N.; Villa, F.; Cuttaia, F.; Ade, P. A. R.; Mauskopf, P.; Orlando, A.; Encrenaz, P.; Pardo, J. R.; Cernicharo, J.

    CASPER (Concordia Atmospheric SPectroscopy of Emitted Radiation) is a spectrometer proposed for installation at Dome C, devoted to measurements of atmospheric emission in the spectral region between 180 μm and 3 mm (3 55 cm-1). This instrument will be able to perform continuous spectral sampling at different altitudes at angular scales of 1°. From the recorded data it is possible to extract atmospheric transmittance within 1% in the whole wide operating band, together with water vapour content and O{2} and O{3} concentrations. CASPER will allow us to characterize the site for future FIR/mm telescopes. Atmospheric data recorded by CASPER will allow for correction of astrophysical and cosmological observations without the need for telescope-specific procedures and further loss of observation time with more precision in the observations themselves. Calibration of ground-based telescopes on known sky sources is strongly affected by atmospheric absorption. CASPER has this as its primary goal. The spectrometer is based on a Martin-Puplett interferometer. Two data sampling solutions will be performed: phase modulation & fast scan strategy. Sky radiation is collected towards the interferometer by an optical setup that allows the field of view, to explore the full 0° div 90° range of elevation angles. With a low spurious polarization instrument, monitoring of polarized atmospheric contribution will be possible.

  6. Exposure to radiofrequency radiation from diathermy units in medicine

    International Nuclear Information System (INIS)

    Hrnjak, M.; Zivkovic, D.; Milicevic, L.

    1998-01-01

    Intensities of microwave (MW) and radio wave (short wave) radiation to whom personnel occupied in use of radiofrequency (RF) diathermy in physical therapy could be exposed were measured in two hospitals, in two therapy wards. The Narda Microwave Corp. (USA) Broadband Radiation Meter - Model 8616, with appropriate probes, was used for measurements. The measurements were performed around the 3 types of diathermy units in various ways of application. Results of the measurements showed that the intensities of short waves radiation around the applicators, cables and units (at the distance of 30 cm) ranged from 187 mW/cm sup 2 , and on the majority of measuring points were considerably over the upper exposure limit of 1,22 mW/cm sup 2 (according to JUS N.NO.205:1190 limits of exposure to RF fields). Intensities of microwave radiation in the vicinity of units and patient range from <0,002 to 1,45 mW/cm sup 2. The intensities of MW radiation are over the exposure limit of 1 mW/cm sup 2 in two measuring points. Results of measurements show that personnel occupied in use of microwave and short wave diathermy in medicine could be regularly exposed to radiation, and that this radiation has considerably high intensity in the vicinity of the therapy unit and patient (author)

  7. Radiofrequency radiation exposure from RF-generating plant

    International Nuclear Information System (INIS)

    Wright, J.M.; Bell, K.M.

    2000-01-01

    As part of an intervention to assist industry improve the control of risks associated with the use of RF-generating plant, exposure to radiofrequency radiation (RFR) was assessed in 30 workplaces. Information about the workplace, work practices and knowledge about RFR and its control was also collected. The study found that: 1. For 72% of operators and 35% of bystanders, the spatially averaged exposure exceeded the exposure limits. These figures approximately halved when the duty cycle was applied; 2. Assessment of RFR levels was not common; 3. Task rotation was used to limit exposure of operators; 4. Access was not controlled to areas where RFR sources were used; 5. There was lack of knowledge about RF shielding practices in industry; 6. Nearly 50% of workplaces did not maintain the plant regularly; and 7. There had been no health surveillance on any plant operators in any of the workplaces in the study. Copyright (2000) Australasian Radiation Protection Society Inc

  8. Effect of radiofrequency radiation from Wi-Fi devices on mercury release from amalgam restorations.

    Science.gov (United States)

    Paknahad, Maryam; Mortazavi, S M J; Shahidi, Shoaleh; Mortazavi, Ghazal; Haghani, Masoud

    2016-01-01

    Dental amalgam is composed of approximately 50% elemental mercury. Despite concerns over the toxicity of mercury, amalgam is still the most widely used restorative material. Wi-Fi is a rapidly using local area wireless computer networking technology. To the best of our knowledge, this is the first study that evaluates the effect of exposure to Wi-Fi signals on mercury release from amalgam restorations. Standard class V cavities were prepared on the buccal surfaces of 20 non-carious extracted human premolars. The teeth were randomly divided into 2 groups (n = 10). The control group was stored in non-environment. The specimens in the experimental groups were exposed to a radiofrequency radiation emitted from standard Wi Fi devices at 2.4 GHz for 20 min. The distance between the Wi-Fi router and samples was 30 cm and the router was exchanging data with a laptop computer that was placed 20 m away from the router. The concentration of mercury in the artificial saliva in the groups was evaluated by using a cold-vapor atomic absorption Mercury Analyzer System. The independent t test was used to evaluate any significant differences in mercury release between the two groups. The mean (±SD) concentration of mercury in the artificial saliva of the Wi-Fi exposed teeth samples was 0.056 ± .025 mg/L, while it was only 0.026 ± .008 mg/L in the non-exposed control samples. This difference was statistically significant (P =0.009). Exposure of patients with amalgam restorations to radiofrequency radiation emitted from conventional Wi-Fi devices can increase mercury release from amalgam restorations.

  9. Radiofrequency radiation injures trees around mobile phone base stations.

    Science.gov (United States)

    Waldmann-Selsam, Cornelia; Balmori-de la Puente, Alfonso; Breunig, Helmut; Balmori, Alfonso

    2016-12-01

    In the last two decades, the deployment of phone masts around the world has taken place and, for many years, there has been a discussion in the scientific community about the possible environmental impact from mobile phone base stations. Trees have several advantages over animals as experimental subjects and the aim of this study was to verify whether there is a connection between unusual (generally unilateral) tree damage and radiofrequency exposure. To achieve this, a detailed long-term (2006-2015) field monitoring study was performed in the cities of Bamberg and Hallstadt (Germany). During monitoring, observations and photographic recordings of unusual or unexplainable tree damage were taken, alongside the measurement of electromagnetic radiation. In 2015 measurements of RF-EMF (Radiofrequency Electromagnetic Fields) were carried out. A polygon spanning both cities was chosen as the study site, where 144 measurements of the radiofrequency of electromagnetic fields were taken at a height of 1.5m in streets and parks at different locations. By interpolation of the 144 measurement points, we were able to compile an electromagnetic map of the power flux density in Bamberg and Hallstadt. We selected 60 damaged trees, in addition to 30 randomly selected trees and 30 trees in low radiation areas (n=120) in this polygon. The measurements of all trees revealed significant differences between the damaged side facing a phone mast and the opposite side, as well as differences between the exposed side of damaged trees and all other groups of trees in both sides. Thus, we found that side differences in measured values of power flux density corresponded to side differences in damage. The 30 selected trees in low radiation areas (no visual contact to any phone mast and power flux density under 50μW/m 2 ) showed no damage. Statistical analysis demonstrated that electromagnetic radiation from mobile phone masts is harmful for trees. These results are consistent with the fact

  10. Cytogenetic investigation of subjects professionally exposed to radiofrequency radiation.

    Science.gov (United States)

    Maes, Annemarie; Van Gorp, Urbain; Verschaeve, Luc

    2006-03-01

    Nowadays, virtually everybody is exposed to radiofrequency radiation (RFR) from mobile phone base station antennas or other sources. At least according to some scientists, this exposure can have detrimental health effects. We investigated cytogenetic effects in peripheral blood lymphocytes from subjects who were professionally exposed to mobile phone electromagnetic fields in an attempt to demonstrate possible RFR-induced genetic effects. These subjects can be considered well suited for this purpose as their RFR exposure is 'normal' though rather high, and definitely higher than that of the 'general population'. The alkaline comet assay, sister chromatid exchange (SCE) and chromosome aberration tests revealed no evidence of RFR-induced genetic effects. Blood cells were also exposed to the well known chemical mutagen mitomycin C in order to investigate possible combined effects of RFR and the chemical. No cooperative action was found between the electromagnetic field exposure and the mutagen using either the comet assay or SCE test.

  11. Automated radiofrequency radiation dosimetry. Final report, Jun 89-Sep 90

    Energy Technology Data Exchange (ETDEWEB)

    Gandhi, O.P.

    1990-12-01

    The interaction of radiofrequency (RF) and microwave (MW) electromagnetic radiation with biological tissues is of increasing importance from the standpoint of health and safety. From considerable literature devoted to the study of RF and MW bioeffects based primarily on animal experimentation it has been determined that bioeffects are correlated with mass-normalized rates of RF or MW energy absorption (specific absorption rates or SARs). An emphasis of our project was to improve the efficiency of the SAR algorithms and to extend their use to higher RF and MW frequencies. Another objective was to adapt these algorithms to computing workstations and distributed memory parallel processors that are becoming more affordable and hence readily available to potential users of these codes.

  12. Measurement of Radiofrequency Radiation Exposure in Epidemiological Studies (invited paper)

    International Nuclear Information System (INIS)

    Swerdlow, A.J.

    1999-01-01

    The measurement of radiofrequency (RF) exposure is important to the quality of epidemiological studies of the possible association of RF exposure with disease. The extent and type of exposure measurement in past epidemiological studies of RF, and the features of measurement that would be desirable for better studies in the future are summarised. Measurement characteristics that are discussed include quantification of radiation frequency and of intensity and timing of exposures, measurement (or good estimation) of exposures for individuals rather than only for groups, quality of measurement, and measurement of RF exposures experienced outside the study setting. Integration of exposure measurement into the design of epidemiological studies is needed for better assessments of possible RF effects. (author)

  13. Assessment of occupational exposure to radiofrequency fields and radiation

    International Nuclear Information System (INIS)

    Cooper, T. G.; Allen, S. G.; Blackwell, R. P.; Litchfield, I.; Mann, S. M.; Pope, J. M.; Van Tongeren, M. J. A.

    2004-01-01

    The use of personal monitors for the assessment of exposure to radiofrequency fields and radiation in potential future epidemiological studies of occupationally exposed populations has been investigated. Data loggers have been developed for use with a commercially available personal monitor and these allowed personal exposure records consisting of time-tagged measurements of electric and magnetic field strength to be accrued over extended periods of the working day. The instrumentation was worn by workers carrying out tasks representative of some of their typical daily activities at a variety of radio sites. The results indicated significant differences in the exposures of workers in various RF environments. A number of measures of exposure have been examined with a view to assessing possible exposure metrics for epidemiological studies. There was generally a good correlation between a given measure of electric field strength and the same measure of magnetic field strength. (authors)

  14. Can a tachyon emit light radiation in all directions

    Energy Technology Data Exchange (ETDEWEB)

    Ramanujam, G A [NGM Coll., Tamil Nadu (India). Dept. of Physics

    1976-03-01

    It is shown here that a critical analysis of the approaches employed by various authors to accommodate tachyons into special relativity leads one to the conclusion that a tachyon can emit light radiation only along its line of motion.

  15. RADIOFREQUENCY AND MICROWAVE RADIATION HEALTH EFFECTS AND OCCUPATIONAL EXPOSURE

    Directory of Open Access Journals (Sweden)

    Ivana Damnjanović

    2011-12-01

    Full Text Available In the recent years, there have been considerable discussion and concern about the possible hazards of RF/MW radiation. More recently, the growth and development in personal mobile communications have focused attention on the frequencies associated with this technology. A number of studies have examined the health effects of RF/MW electromagnetic fields (EMFs, originating from occupational exposure, hobbies, or residence near the radio or television transmitters. Particularly controversial are the biophysical mechanisms by which these RF fields may affect biological systems. General health effects reviews explore possible carcinogenic, reproductive and neurological effects. Health effects by exposure source have been observed in radar traffic devices, wireless communications with cellular phones, radio transmission, and magnetic resonance imaging (MRI. Several epidemiological surveys have suggested associations with non-specific complaints such as headache, tiredness, sleep disturbance, loss of memory, and dizziness. These findings, which echo reports of illness associated with other types of radiofrequency (RF radiation, relate not only to the use of mobile phones, but also to residence near the mobile phone base stations and other settings involving occupational exposure. The biological effects suggest that some precautions are necessary, and preventive approaches are highly recommended. Further researches are required to give more information about the effects of microwave radiation on our health, especially in occupational setting and professionally exposed workers.

  16. SOR/72-43 Radiation Emitting Devices Regulations

    International Nuclear Information System (INIS)

    1972-01-01

    These Regulations of 10 February 1972, supplemented by SOR/77-895, lay down the classes of radiation emitting devices for the purposes of the Radiation Emitting Devices Act. They lay down their standards of design and construction and warning sign specifications and provide for the procedure to be followed by inspectors of such devices. The devices include inter alia extra-oral dental x-ray equipment, baggage inspection x-ray devices, laser scanners, television receivers. (NEA)

  17. Effects of radiation from a radiofrequency identification (RFID) microchip on human cancer cells.

    Science.gov (United States)

    Lai, Henry C; Chan, Ho Wing; Singh, Narendra P

    2016-01-01

    Radiofrequency identification (RFID) microchips are used to remotely identify objects, e.g. an animal in which a chip is implanted. A passive RFID microchip absorbs energy from an external source and emits a radiofrequency identification signal which is then decoded by a detector. In the present study, we investigated the effect of the radiofrequency energy emitted by a RFID microchip on human cancer cells. Molt-4 leukemia, BT474 breast cancer, and HepG2 hepatic cancer cells were exposed in vitro to RFID microchip-emitted radiofrequency field for 1 h. Cells were counted before and after exposure. Effects of pretreatment with the spin-trap compound N-tert-butyl-alpha-phenylnitrone or the iron-chelator deferoxamine were also investigated. Results We found that the energy effectively killed/retarded the growth of the three different types of cancer cells, and the effect was blocked by the spin-trap compound or the iron-chelator, whereas an inactive microchip and energy from the external source had no significant effect on the cells. Conclusions Data of the present study suggest that radiofrequency field from the microchip affects cancer cells via the Fenton Reaction. Implantation of RFID microchips in tumors may provide a new method for cancer treatment.

  18. Explanation for Cancer in Rats, Mice and Humans due to Cell Phone Radiofrequency Radiation

    OpenAIRE

    Feldman, Bernard J.

    2016-01-01

    Very recently, the National Toxicology Program reported a correlation between exposure to whole body 900 MHz radiofrequency radiation and cancer in the brains and hearts of Sprague Dawley male rats. This paper proposes the following explanation for these results. The neurons around the rat's brain and heart form closed electrical circuits and, following Faraday's Law, 900 MHz radiofrequency radiation induces 900 MHz electrical currents in these neural circuits. In turn, these 900 MHz currents...

  19. An assessment of ultraviolet radiation components of light emitted ...

    African Journals Online (AJOL)

    An assessment of ultraviolet radiation components of light emitted from electric arc and their possible exposure risks. ... The study of Ultraviolet Radiation has of recent become interesting because of the health hazards it poses to human. Apart from its intensity reaching the earth from the sun, other man-made sources have ...

  20. Cell oxidation-reduction imbalance after modulated radiofrequency radiation.

    Science.gov (United States)

    Marjanovic, Ana Marija; Pavicic, Ivan; Trosic, Ivancica

    2015-01-01

    Aim of this study was to evaluate an influence of modulated radiofrequency field (RF) of 1800 MHz, strength of 30 V/m on oxidation-reduction processes within the cell. The assigned RF field was generated within Gigahertz Transversal Electromagnetic Mode cell equipped by signal generator, modulator, and amplifier. Cell line V79, was irradiated for 10, 30, and 60 min, specific absorption rate was calculated to be 1.6 W/kg. Cell metabolic activity and viability was determined by MTT assay. In order to define total protein content, colorimetric method was used. Concentration of oxidised proteins was evaluated by enzyme-linked immunosorbent assay. Reactive oxygen species (ROS) marked with fluorescent probe 2',7'-dichlorofluorescin diacetate were measured by means of plate reader device. In comparison with control cell samples, metabolic activity and total protein content in exposed cells did not differ significantly. Concentrations of carbonyl derivates, a product of protein oxidation, insignificantly but continuously increase with duration of exposure. In exposed samples, ROS level significantly (p < 0.05) increased after 10 min of exposure. Decrease in ROS level was observed after 30-min treatment indicating antioxidant defence mechanism activation. In conclusion, under the given laboratory conditions, modulated RF radiation might cause impairment in cell oxidation-reduction equilibrium within the growing cells.

  1. Tinnitus and cell phones: the role of electromagnetic radiofrequency radiation.

    Science.gov (United States)

    Medeiros, Luisa Nascimento; Sanchez, Tanit Ganz

    2016-01-01

    Tinnitus is a multifactorial condition and its prevalence has increased on the past decades. The worldwide progressive increase of the use of cell phones has exposed the peripheral auditory pathways to a higher dose of electromagnetic radiofrequency radiation (EMRFR). Some tinnitus patients report that the abusive use of mobiles, especially when repeated in the same ear, might worsen ipsilateral tinnitus. The aim of this study was to evaluate the available evidence about the possible causal association between tinnitus and exposure to electromagnetic waves. A literature review was performed searching for the following keywords: tinnitus, electromagnetic field, mobile phones, radio frequency, and electromagnetic hypersensitivity. We selected 165 articles that were considered clinically relevant in at least one of the subjects. EMRFR can penetrate exposed tissues and safety exposure levels have been established. These waves provoke proved thermogenic effects and potential biological and genotoxic effects. Some individuals are more sensitive to electromagnetic exposure (electrosensitivity), and thus, present earlier symptoms. There may be a common pathophysiology between this electrosensitivity and tinnitus. There are already reasonable evidences to suggest caution for using mobile phones to prevent auditory damage and the onset or worsening of tinnitus. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  2. Public Exposure from Indoor Radiofrequency Radiation in the City of Hebron, West Bank-Palestine.

    Science.gov (United States)

    Lahham, Adnan; Sharabati, Afefeh; ALMasri, Hussien

    2015-08-01

    This work presents the results of measured indoor exposure levels to radiofrequency (RF) radiation emitting sources in one of the major cities in the West Bank-the city of Hebron. Investigated RF emitters include FM, TV broadcasting stations, mobile telephony base stations, cordless phones [Digital Enhanced Cordless Telecommunications (DECT)], and wireless local area networks (WLAN). Measurements of power density were conducted in 343 locations representing different site categories in the city. The maximum total power density found at any location was about 2.3 × 10 W m with a corresponding exposure quotient of about 0.01. This value is well below unity, indicating compliance with the guidelines of the International Commission on Non-ionizing Radiation Protection (ICNIRP). The average total exposure from all RF sources was 0.08 × 10 W m. The relative contributions from different sources to the total exposure in terms of exposure quotient were evaluated and found to be 46% from FM radio, 26% from GSM900, 15% from DECT phones, 9% from WLAN, 3% from unknown sources, and 1% from TV broadcasting. RF sources located outdoors contribute about 73% to the population exposure indoors.

  3. Industrial assessment of radiofrequency and microwave radiations: case study at electronic manufacturing industries in Penang

    International Nuclear Information System (INIS)

    Mohd Zaid Abdullah

    1996-01-01

    In electronic manufacturing industry, the applications of an equipment emitting radiofrequency radiation (RFR) are numerous and Increasing. It is known that exposure to RFR at sufficiently high intensity and duration can produce a variety of adverse health effects. This paper presents some results from an extensive studies in the RFR field measurements at frequency range from 100 MHz to 1 GHz. All measurements were performed inside factories located at the Penang Free Trade Zone. In this case, the factories chosen are those that manufacture the electronic components whereby the applications of RFR equipment are likely to be intensive compared to other type of industries. The measurement system used in this study are the portable spectrum-analyzer, the passive log-periodic antenna and a desktop computer for data analysis. Results from this study have indicated that the RFR exposure levels in most factories are in the range of 7.7 x 10 sup -4 - 4.31 x 10 sup -3 Wm sup -2 and 0.01 - 0. 741 Vm sup -1 for power density and electric strength measurement respectively. These ranges are at least 100 times lower compared to the RFR protection guidelines proposed by the American National Standard Institute (ANSI). However, the exposure levels inside the factory are consistently 10 sup -3 - 10 sup -4 higher than the levels caused by natural sources and is about 10 sup 2 - 10 sup 6 higher than the levels measured at a distance of 30 m from a low-power output mobile phone transmitter. In the case of the health effect assessment, no sufficient evidence has been found to indicate the potential consequences resulting from excessive RFR exposure. Nonetheless, many factories surveyed are unaware of the existence of the international guidelines and codes on the safe use of radiofrequency energy even though, some measures are being taken to protect their employees against RFR

  4. Comparison of GSM Modulated and CW Radiofrequency Radiation on Cells

    International Nuclear Information System (INIS)

    Pavicic, I.; Marjanovic, A.M.; Trosic, I.

    2011-01-01

    The aim of our study was to evaluate and compare effect of global system of mobile (GSM) modulation and continuous wave (CW) radiofrequency radiation (RF) on proliferation ability and viability of V79 Chinese hamster lung cells. Previously prepared samples of cells in culture were exposed for 1, 2 and 3 hours both to 915 MHz GSM modulated and to 935 MHz CW RF field in gigahertz transversal electromagnetic mode cell (GTEM-cell). Electric field strength for cells exposed to GSM modulation was set at 10 V/m and for CW exposed cells was 8.2 V/m. Average specific absorption rate (SAR) was calculated to be for GSM 0.23 W/kg and for CW 0.12 W/kg. V79 samples were plated in concentration of 1x10 4 cells/mL. Cell proliferation was determined by cell counts for each hour of exposure during five post-exposure days. Trypan blue exclusion test was used to determine cell viability. In comparison to control cell samples, proliferation of GSM irradiated cells showed significant decrease after 3 hours of exposure on the second and third post-exposure day. CW exposed cell samples showed significant decrease after 3 hours of exposure on the third post-exposure day. Viability of GSM and CW exposed cells did not significantly differ from matched control cell samples. Both applied RF fields have shown similar effect on cell culture growth, and cell viability of V79 cell line. In addition, applied GSM modulated RF radiation demonstrate bigger influence on proliferation of cells. (author)

  5. Exposure to radiofrequency radiation induces oxidative stress in duckweed Lemna minor L

    International Nuclear Information System (INIS)

    Tkalec, Mirta; Malaric, Kresimir; Pevalek-Kozlina, Branka

    2007-01-01

    Widespread use of radiofrequency radiation emitting devices increased the exposure to electromagnetic fields (EMFs) from 300 MHz to 300 GHz. Various biological effects of exposure to these fields have been documented so far, but very little work has been carried out on plants. The aim of the present work was to investigate the physiological responses of the plant Lemna minor after exposure to radiofrequency EMFs, and in particular, to clarify the possible role of oxidative stress in the observed effects. Duckweed was exposed for 2 h to EMFs of 400 and 900 MHz at field strengths of 10, 23, 41 and 120 V m -1 . The effect of a longer exposure time (4 h) and modulation was also investigated. After exposure, parameters of oxidative stress, such as lipid peroxidation, H 2 O 2 content, activities and isoenzyme pattern of antioxidative enzymes as well as HSP70 expression were evaluated. At 400 MHz, lipid peroxidation and H 2 O 2 content were significantly enhanced in duckweed exposed to EMFs of 23 and 120 V m -1 while other exposure treatments did not have an effect. Compared to the controls, the activities of antioxidative enzymes showed different behaviour: catalase (CAT) activity increased after most exposure treatments while pyrogallol (PPX) and ascorbate peroxidase (APX) activities were not changed. Exceptions were reduced PPX and APX activity after longer exposure at 23 V m -1 and increased PPX activity after exposures at 10 and 120 V m -1 . By contrast, at 900 MHz almost all exposure treatments significantly increased level of lipid peroxidation and H 2 O 2 content but mostly decreased PPX activity and did not affect CAT activity. Exceptions were exposures to a modulated field and to the field of 120 V m -1 which increased PPX and CAT activity. At this frequency APX activity was significantly decreased after exposure at 10 V m -1 and longer exposure at 23 V m -1 but it increased after a shorter exposure at 23 V m -1 . At both frequencies no differences in isoenzyme

  6. The effect of 2100 MHz radiofrequency radiation of a 3G mobile phone on the parotid gland of rats.

    Science.gov (United States)

    Aydogan, Filiz; Unlu, Ilhan; Aydin, Emine; Yumusak, Nihat; Devrim, Erdinc; Samim, Ethem Erdal; Ozgur, Elcin; Unsal, Velid; Tomruk, Arin; Ozturk, Goknur Guler; Seyhan, Nesrin

    2015-01-01

    We aimed to evaluate the effect of 2100 MHz radiofrequency radiation on the parotid gland of rats in short and relatively long terms. Thirty Wistar albino rats were divided into four groups. Groups A and B served as the control groups (for 10 days and 40 days, respectively), and each group included six rats. Groups C and D were composed of nine rats each, and they were the exposure groups. The rats were exposed to 2100 MHz radiofrequency radiation emitted by a generator, simulating a third generation mobile phone for 6 hours/day, 5 days/week, for 10 or 40 days. Following exposure, the rats were sacrificed and parotid glands were removed. Histopathological and biochemical examinations were performed. Although there were no histopathological changes in the control groups except for two animals in group A and three animals in group B, the exposure groups C (10 days) and D (40 days) showed numerous histopathological changes regarding salivary gland damage including acinar epithelial cells, interstitial space, ductal system, vascular system, nucleus, amount of cytoplasm and variations in cell size. The histopathological changes were more prominent in group D compared to group C. There was statistically significant different parameter regarding variation in cell size between the groups B and D (p=0.036). The parotid gland of rats showed numerous histopathological changes after exposure to 2100 MHz radiofrequency radiation, both in the short and relatively long terms. Increased exposure duration led to an increase in the histopathological changes. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Measurement and analysis of radiofrequency radiations from some mobile phone base stations in Ghana

    International Nuclear Information System (INIS)

    Amoako, J. K.; Fletcher, J. J.; Darko, E. O.

    2009-01-01

    A survey of the radiofrequency electromagnetic radiation at public access points in the vicinity of 50 cellular phone base stations has been carried out. The primary objective was to measure and analyse the electromagnetic field strength levels emitted by antennae installed and operated by the Ghana Telecommunications Company. On all the sites measurements were made using a hand-held spectrum analyser to determine the electric field level with the 900 and 1800 MHz frequency bands. The results indicated that power densities at public access points varied from as low as 0.01 μW m -2 to as high as 10 μW m -2 for the frequency of 900 MHz. At a transmission frequency of 1800 MHz, the variation of power densities is from 0.01 to 100 μW m -2 . The results were found to be in compliant with the International Commission on Non-ionizing Radiological Protection guidance level but were 20 times higher than the results generally obtained for such a practice elsewhere. There is therefore a need to re-assess the situation to ensure reduction in the present level as an increase in mobile phone usage is envisaged within the next few years. (authors)

  8. Measurement and analysis of radiofrequency radiations from some mobile phone base stations in Ghana.

    Science.gov (United States)

    Amoako, J K; Fletcher, J J; Darko, E O

    2009-08-01

    A survey of the radiofrequency electromagnetic radiation at public access points in the vicinity of 50 cellular phone base stations has been carried out. The primary objective was to measure and analyse the electromagnetic field strength levels emitted by antennae installed and operated by the Ghana Telecommunications Company. On all the sites measurements were made using a hand-held spectrum analyser to determine the electric field level with the 900 and 1800 MHz frequency bands. The results indicated that power densities at public access points varied from as low as 0.01 microW m(-2) to as high as 10 microW m(-2) for the frequency of 900 MHz. At a transmission frequency of 1800 MHz, the variation of power densities is from 0.01 to 100 microW m(-2). The results were found to be in compliant with the International Commission on Non-ionizing Radiological Protection guidance level but were 20 times higher than the results generally obtained for such a practice elsewhere. There is therefore a need to re-assess the situation to ensure reduction in the present level as an increase in mobile phone usage is envisaged within the next few years.

  9. Radiofrequency electromagnetic radiation exposure inside the metro tube infrastructure in Warszawa.

    Science.gov (United States)

    Gryz, Krzysztof; Karpowicz, Jolanta

    2015-09-01

    Antennas from various wireless communications systems [e.g. mobile phones base transceiver stations (BTS) and handsets used by passengers, public Internet access, staff radiophone transmitters used between engine-drivers and traffic operators] emitting radiofrequency electromagnetic radiation (RF-EMR) are used inside underground metro public transportation. Frequency-selective exposimetric investigations of RF-EMR exposure inside the metro infrastructure in Warsaw (inside metro cars passing between stations and on platforms) were performed. The statistical parameters of exposure to the E-field were analyzed for each frequency range and for a total value (representing the wide-band result of measurements of complex exposure). The recorded exposimetric profiles showed the dominant RF-EMR sources: handsets and BTS of mobile communication systems (GSM 900 and UMTS 2100) and local wireless Internet access (WiFi 2G). Investigations showed that the GSM 900 system is the dominant source of exposure - BTS (incessantly active) on platforms, and handsets - used by passengers present nearby during the tube drive. The recorded E-field varies between sources (for BTS were: medians - 0.22 V/m and 75th percentile - 0.37 V/m; and for handsets: medians - 0.28 V/m and 75th percentile - 0.47 V/m). Maximum levels (peaks) of exposure recorded from mobile handsets exceeded 10 V/m (upper limit of used exposimeters). Broadband measurements of E-field, including the dominant signal emitted by staff radiophones (151 MHz), showed that the level of this exposure of engine-drivers does not exceed 2.5 V/m.

  10. Safety assessment of RF and microwave radiation emitted by the mobile telephone base station (MTBS) in Malaysia: experience and challenge

    International Nuclear Information System (INIS)

    Roha Tukimin; Rozaimah Abd Rahim; Mohamad Amirul Nizam; Mohd Yusof Mohd Ali

    2007-01-01

    Non-ionising radiation (NIR) is known to be hazardous if the amount received is excessive. It is a fact that NIR, including extremely low frequency (ELF) electromagnetic fields, radiofrequency (RF) and microwave radiation can be found almost everywhere generated by both natural and man-made source. This is due to increase in demand for telecommunication and wireless technology which is become very important and as part of our lives. However, the widespread of the relevant technology contributed more NIR man-made sources exposure to the human. Due to public concern their potential of causing such health hazard, members of public and companies approached and request NIR Group of Nuclear Malaysia to carry out surveys and safety assessments of radiofrequency and microwave radiation emitted by the mobile telephone base station (MTBS) erected near the residential area or installed on the rooftop of the commercial building. Objective of the survey was to assess the presence of radiofrequency and microwave radiation and to identify radiation level which may lead to significant personnel exposure. Findings of the survey was compared to the standard guidelines issued by Malaysian Communication and Multimedia Commission (MCMC) and International Committee on Non-Ionising Radiation Protection (ICNIRP). This paper highlights the works that had been carried out by NIR Group of Nuclear Malaysia from 1997 to 2007. We will share the experience and challenge in carried out the NIR safety assessment at mobile telephone base station. Results of the assessment work will be used to develop non-ionising radiation database for future reference in Malaysia. (Author)

  11. A Technical Approach to the Evaluation of Radiofrequency Radiation Emissions from Mobile Telephony Base Stations

    Directory of Open Access Journals (Sweden)

    Raimondas Buckus

    2017-03-01

    Full Text Available During the last two decades, the number of macrocell mobile telephony base station antennas emitting radiofrequency (RF electromagnetic radiation (EMR in residential areas has increased significantly, and therefore much more attention is being paid to RF EMR and its effects on human health. Scientific field measurements of public exposure to RF EMR (specifically to radio frequency radiation from macrocell mobile telephony base station antennas and RF electromagnetic field (EMF intensity parameters in the environment are discussed in this article. The research methodology is applied according to the requirements of safety norms and Lithuanian Standards in English (LST EN. The article presents and analyses RF EMFs generated by mobile telephony base station antennas in areas accessible to the general public. Measurements of the RF electric field strength and RF EMF power density were conducted in the near- and far-fields of the mobile telephony base station antenna. Broadband and frequency-selective measurements were performed outside (on the roof and on the ground and in a residential area. The tests performed on the roof in front of the mobile telephony base station antennas in the near-field revealed the presence of a dynamic energy interaction within the antenna electric field, which changes rapidly with distance. The RF EMF power density values on the ground at distances of 50, 100, 200, 300, 400, and 500 m from the base station are very low and are scattered within intervals of 0.002 to 0.05 μW/cm2. The results were compared with international exposure guidelines (ICNIRP.

  12. A Technical Approach to the Evaluation of Radiofrequency Radiation Emissions from Mobile Telephony Base Stations.

    Science.gov (United States)

    Buckus, Raimondas; Strukčinskienė, Birute; Raistenskis, Juozas; Stukas, Rimantas; Šidlauskienė, Aurelija; Čerkauskienė, Rimantė; Isopescu, Dorina Nicolina; Stabryla, Jan; Cretescu, Igor

    2017-03-01

    During the last two decades, the number of macrocell mobile telephony base station antennas emitting radiofrequency (RF) electromagnetic radiation (EMR) in residential areas has increased significantly, and therefore much more attention is being paid to RF EMR and its effects on human health. Scientific field measurements of public exposure to RF EMR (specifically to radio frequency radiation) from macrocell mobile telephony base station antennas and RF electromagnetic field (EMF) intensity parameters in the environment are discussed in this article. The research methodology is applied according to the requirements of safety norms and Lithuanian Standards in English (LST EN). The article presents and analyses RF EMFs generated by mobile telephony base station antennas in areas accessible to the general public. Measurements of the RF electric field strength and RF EMF power density were conducted in the near- and far-fields of the mobile telephony base station antenna. Broadband and frequency-selective measurements were performed outside (on the roof and on the ground) and in a residential area. The tests performed on the roof in front of the mobile telephony base station antennas in the near-field revealed the presence of a dynamic energy interaction within the antenna electric field, which changes rapidly with distance. The RF EMF power density values on the ground at distances of 50, 100, 200, 300, 400, and 500 m from the base station are very low and are scattered within intervals of 0.002 to 0.05 μW/cm². The results were compared with international exposure guidelines (ICNIRP).

  13. Electromagnetic Fields, Pulsed Radiofrequency Radiation, and Epigenetics: How Wireless Technologies May Affect Childhood Development

    Science.gov (United States)

    Sage, Cindy; Burgio, Ernesto

    2018-01-01

    Mobile phones and other wireless devices that produce electromagnetic fields (EMF) and pulsed radiofrequency radiation (RFR) are widely documented to cause potentially harmful health impacts that can be detrimental to young people. New epigenetic studies are profiled in this review to account for some neurodevelopmental and neurobehavioral changes…

  14. World Health Organization, radiofrequency radiation and health - a hard nut to crack (Review)

    OpenAIRE

    Hardell, Lennart

    2017-01-01

    In May 2011 the International Agency for Research on Cancer (IARC) evaluated cancer risks from radiofrequency (RF) radiation. Human epidemiological studies gave evidence of increased risk for glioma and acoustic neuroma. RF radiation was classified as Group 2B, a possible human carcinogen. Further epidemiological, animal and mechanistic studies have strengthened the association. In spite of this, in most countries little or nothing has been done to reduce exposure and educate people on health...

  15. Survey of radiofrequency radiation levels around GSM base stations and evaluation of measurement uncertainty

    Directory of Open Access Journals (Sweden)

    Vulević Branislav D.

    2011-01-01

    Full Text Available This paper is a summary of broadband measurement values of radiofrequency radiation around GSM base stations in the vicinity of residential areas in Belgrade and 12 other cities in Serbia. It will be useful for determining non-ionizing radiation exposure levels of the general public in the future. The purpose of this paper is also an appropriate representation of basic information on the evaluation of measurement uncertainty.

  16. Review: Weak radiofrequency radiation exposure from mobile phone radiation on plants.

    Science.gov (United States)

    Halgamuge, Malka N

    2017-01-01

    The aim of this article was to explore the hypothesis that non-thermal, weak, radiofrequency electromagnetic fields (RF-EMF) have an effect on living plants. In this study, we performed an analysis of the data extracted from the 45 peer-reviewed scientific publications (1996-2016) describing 169 experimental observations to detect the physiological and morphological changes in plants due to the non-thermal RF-EMF effects from mobile phone radiation. Twenty-nine different species of plants were considered in this work. Our analysis demonstrates that the data from a substantial amount of the studies on RF-EMFs from mobile phones show physiological and/or morphological effects (89.9%, p radiofrequency radiation influence on plants. Hence, this study provides new evidence supporting our hypothesis. Nonetheless, this endorses the need for more experiments to observe the effects of RF-EMFs, especially for the longer exposure durations, using the whole organisms. The above observation agrees with our earlier study, in that it supported that it is not a well-grounded method to characterize biological effects without considering the exposure duration. Nevertheless, none of these findings can be directly associated with human; however, on the other hand, this cannot be excluded, as it can impact the human welfare and health, either directly or indirectly, due to their complexity and varied effects (calcium metabolism, stress proteins, etc.). This study should be useful as a reference for researchers conducting epidemiological studies and the long-term experiments, using whole organisms, to observe the effects of RF-EMFs.

  17. Exposure to radiofrequency radiation induces oxidative stress in duckweed Lemna minor L

    Energy Technology Data Exchange (ETDEWEB)

    Tkalec, Mirta [Department of Botany, Division of Biology, Faculty of Science, University of Zagreb, Rooseveltov trg 6, HR-10000 Zagreb (Croatia)], E-mail: mtkalec@zg.biol.pmf.hr; Malaric, Kresimir [Faculty of Electrical Engineering and Computing, University of Zagreb, Unska 3, HR-10000 Zagreb (Croatia); Pevalek-Kozlina, Branka [Department of Botany, Division of Biology, Faculty of Science, University of Zagreb, Rooseveltov trg 6, HR-10000 Zagreb (Croatia)

    2007-12-15

    Widespread use of radiofrequency radiation emitting devices increased the exposure to electromagnetic fields (EMFs) from 300 MHz to 300 GHz. Various biological effects of exposure to these fields have been documented so far, but very little work has been carried out on plants. The aim of the present work was to investigate the physiological responses of the plant Lemna minor after exposure to radiofrequency EMFs, and in particular, to clarify the possible role of oxidative stress in the observed effects. Duckweed was exposed for 2 h to EMFs of 400 and 900 MHz at field strengths of 10, 23, 41 and 120 V m{sup -1}. The effect of a longer exposure time (4 h) and modulation was also investigated. After exposure, parameters of oxidative stress, such as lipid peroxidation, H{sub 2}O{sub 2} content, activities and isoenzyme pattern of antioxidative enzymes as well as HSP70 expression were evaluated. At 400 MHz, lipid peroxidation and H{sub 2}O{sub 2} content were significantly enhanced in duckweed exposed to EMFs of 23 and 120 V m{sup -1} while other exposure treatments did not have an effect. Compared to the controls, the activities of antioxidative enzymes showed different behaviour: catalase (CAT) activity increased after most exposure treatments while pyrogallol (PPX) and ascorbate peroxidase (APX) activities were not changed. Exceptions were reduced PPX and APX activity after longer exposure at 23 V m{sup -1} and increased PPX activity after exposures at 10 and 120 V m{sup -1}. By contrast, at 900 MHz almost all exposure treatments significantly increased level of lipid peroxidation and H{sub 2}O{sub 2} content but mostly decreased PPX activity and did not affect CAT activity. Exceptions were exposures to a modulated field and to the field of 120 V m{sup -1} which increased PPX and CAT activity. At this frequency APX activity was significantly decreased after exposure at 10 V m{sup -1} and longer exposure at 23 V m{sup -1} but it increased after a shorter exposure at

  18. Nonionising radiation and risk of human cancer: comparison of ultraviolet and radiofrequency radiation

    International Nuclear Information System (INIS)

    Green, A.

    2003-01-01

    Human exposure to ultraviolet radiation (UVR) comes largely from sunlight, although a small proportion of people receive high dose UVR from artificial sources. The causal link between solar UVR and the keratinocyte cancers, basal cell carcinomas and squamous cell carcinomas of the skin, is well-established based on a large body of observational and experimental evidence. UVR damages molecules such as DNA directly and this is the principal mechanism of carcinogenesis, though other mechanisms such as immunosuppression and interaction with viruses may also be involved. People are also exposed to another form of nonionising radiation, radiofrequency radiation (RFR), through occupation, the community environment from base stations, and through use of cellular telephones and related communications devices. However, unlike UVR, the relationship between RFR and cancer is far from clear. The main tumours that have been investigated to date are brain tumours and leukaemia but assessing the RFR exposure pathway to such cancers poses many methodological challenges for epidemiologists. Refinements to measurement of exposure are the major urgent need, and the lack of evidence regarding carcinogenic effects of RFR in experimental settings complicates the assessment. Further insights into the links between RFR and chronic disease such as cancer are likely in the next few years however when results of several large-scale epidemiological studies now in train around the world become available

  19. Radiative flux emitted by a burning PMMA slab

    International Nuclear Information System (INIS)

    Parent, G; Acem, Z; Collin, A; Berfroi, R; Boulet, P; Pizzo, Y; Mindykowski, P; Kaiss, A; Porterie, B

    2012-01-01

    The degradation of a PMMA sample has been studied based on experimental results obtained for the radiation emission by a burning slab. Observations of the infrared emission perpendicular to the plate, in the range where the optically thin flame is weakly emitting, indicate a plate temperature close to 680 K which is an indication on the surface temperature during the degradation process. Observations from the side allow a flame characterization without the plate emission superimposition. This is a promising way for evaluating data regarding the flame characteristics: temperature, gaz concentration and soot volumetric fraction.

  20. Null bactericidal effect of ultraviolet radiation emitted by LEDs.

    Directory of Open Access Journals (Sweden)

    Francisco Alcántara Muñoz

    2016-11-01

    Full Text Available This research has aimed to assess the bactericidal effect of ultraviolet light emitted by LEDS on the growth on Petri dishes of microorganisms whose legal limits in foods have been established. An electrically fed apparatus has been designed with precise timing and a camera to prevent light spillage, in which two ultraviolet radiation emission devices were connected by LED technology at different wavelengths: through an array of LEDS emitting at around 350nm, and a single specific emission LED at 280nm. 1000 cfu of E. Coli and S. aureus sown on PCA were used as prototypes of gram negative and positive bacteria, respectively, onto which ultraviolet light was radiated at different time intervals, by means of both devices, with the whole experiment being carried out in triplicate . In none of the three series of treatments at the two wavelengths were reductions in microbial growth observed. The series of sowings on PCA were done on unseeded plates in order to be able to discard the likelihood of subsequent recontamination.

  1. Potential health risks due to telecommunications radiofrequency radiation exposures in Lagos State Nigeria.

    Science.gov (United States)

    Aweda, M A; Ajekigbe, A T; Ibitoye, A Z; Evwhierhurhoma, B O; Eletu, O B

    2009-01-01

    The global system mobile telecommunications system (GSM) which was recently introduced in Nigeria is now being used by over 40 million people in Nigeria. The use of GSM is accompanied with exposure of the users to radiofrequency radiation (RFR), which if significant, may produce health hazards. This is the reason why many relevant national and international organizations recommended exposure limits to RFR and why it is made compulsory for GSM handsets to indicate the maximum power output as a guide to potential consumers. This study was conducted to measure the RFR output power densities (S) from the most commonly used GSM handsets used in Lagos State and compare with the limit recommended for safety assessment. Over 1100 most commonly used handsets of different makes and models as well as wireless phones were sampled and studied in all over the local government areas of the State. An RFR meter, Electrosmog from LESSEMF USA was used for the measurements. The handsets were assessed for health risks using the reference value of 9 Wm(-2) as recommended by the International Commission on Non-Ionizing Radiation Protection (ICNIRP). The range of the S-values obtained varied from a minimum of 1.294 0.101 Wm(-2) with Siemens model R228 to a maximum of 16.813 +/- 0.094 Wm(-2) with Samsung model C140*. The results from wireless telephones showed very low S-values ranging from a minimum of 0.024 +/- 0.001 Wm(-2) with HUAWEI and ST CDMA 1 to a maximum of 0.093 +/- 0.002 Wm(-2) with HISENSE. The results showed that the population in Lagos State may be at risk due to significant RFR exposures resulting principally from the use of GSM. Quite a number of handsets emit power above the ICNIRP recommended value. Measured RFR power close to Radio and Television masts and transmitters are within tolerable limits in most cases, only that the public should not reside or work close to RFR installations. Phone calls with GSM should be restricted to essential ones while youths and children

  2. Does the cellphone radio-frequency electromagnetic radiation ...

    African Journals Online (AJOL)

    Debate regarding the biological effect of electromagnetic radiation has been recently raised. The effects of this radiation on locomotor activity are not well known. Hence, in this study, we used Drosophila melanogaster as a model organism to investigate the possible effects of short-term exposure to ringing or talking ...

  3. Quantum dot superluminescent light emitting diodes: Ideal blackbody radiators?

    Energy Technology Data Exchange (ETDEWEB)

    Blazek, Martin; Elsaesser, Wolfgang [Institute of Applied Physics, Darmstadt University of Technology (Germany); Hopkinson, Mark [Dept. E and E.E, University of Sheffield (United Kingdom); Krakowski, Michel [Alcatel Thales, III-V Lab. (France)

    2008-07-01

    Quantum dot (QD) superluminescent light emitting diodes (SLEDs) provide large optical bandwidths at desired wavelengths and are therefore promising devices for incoherent light application. The intensity noise behavior of QD SLEDs is of fundamental physical interest as it provides insight into the photon emission process. We performed high precision intensity noise measurements over several decades of optical output power. For low driving currents spontaneous emission leads to Shot Noise. For high currents we find excess noise behavior with Amplified Spontaneous Emission acting as the dominant source of noise. The QD SLEDs' noise can be described as blackbody radiation noise with a limited number of optical modes. It is therefore possible to identify the SLEDs' relevant intensity noise parameters.

  4. Non-Linear Adaptive Phenomena Which Decrease The Risk of Infection After Pre-Exposure to Radiofrequency Radiation

    OpenAIRE

    Mortazavi, S.M.J.; Motamedifar, M.; Namdari, G.; Taheri, M.; Mortazavi, A.R.; Shokrpour, N.

    2013-01-01

    Substantial evidence indicates that adaptive response induced by low doses of ionizing radiation can result in resistance to the damage caused by a subsequently high-dose radiation or cause cross-resistance to other non-radiation stressors. Adaptive response contradicts the linear-non-threshold (LNT) dose-response model for ionizing radiation. We have previously reported that exposure of laboratory animals to radiofrequency radiation can induce a survival adaptive response. Furthermore, we ha...

  5. ELISA reader does not interfere by mobile phone radiofrequency radiation

    Directory of Open Access Journals (Sweden)

    Seyyed Mohammad Javad Mortazavi

    2016-01-01

    Conclusion: This study showed that ELISA reader does not interfere by mobile phone RF radiation at a closed contact (less than 5 cm distance. However, we recommend that medical institutions discuss these issues in the context of their specific use of technologies and frame a policy that is clear and straightforward to guide staff, patients, and visitors.

  6. ELISA reader does not interfere by mobile phone radiofrequency radiation

    Science.gov (United States)

    Mortazavi, Seyyed Mohammad Javad; Baradaran-Ghahfarokhi, Hamid Reza; Abdi, Mohammad Reza; Baradaran-Ghahfarokhi, Milad; Mostafavi, Nayyer Sadat; Mahmoudi, Golshan; Berenjkoub, Nafiseh; Akmali, Zahra; Hossein-Beigi, Fahimeh; Arsang, Vajiheh

    2016-01-01

    Background: The increasing number of mobile phones can physically cause electromagnetic interference (EMI) in medical environments; can also cause errors in immunoassays in laboratories. The ELISA readers are widely used as a useful diagnostic tool for Enzymun colorimetric assay in medicine. The aim of this study was to investigate whether the ELISA reader could be interfered by the exposure to the 900 MHz cell phones in the laboratory. Materials and Methods: Human serum samples were collected from 14 healthy donors (9 women and 5 men) and each sample was divided into four aliquots and was placed into four batches for the in-vitro quantitative determination of human chorionic gonadotropin (hCG). During colorimetric reading of the first, second, and third batches, the ELISA reader (Stat Fax 2100, Awareness Technology, Inc., USA) was exposed to 0.5, 1.0, and 2.0 W exposure of 900 MHz radiation, respectively. For the forth batch (control group), no radiation was applied. All experiments were performed comparing ELISA read out results of the I, II, and III batches with the control batch, using the Wilcoxon test with criterion level of P = 0.050. Results: The final scores in the exposed batches I, II, and III were not statistically significant relative to the control batch (P > 0.05). The results showed that 900 MHz radiation exposure did not alter the ELISA measured levels of hCG hormone in I (P = 0.219), II (P = 0.909), and III (P = 0.056) batches compared to the control batch. Conclusion: This study showed that ELISA reader does not interfere by mobile phone RF radiation at a closed contact (less than 5 cm distance). However, we recommend that medical institutions discuss these issues in the context of their specific use of technologies and frame a policy that is clear and straightforward to guide staff, patients, and visitors. PMID:27376040

  7. Continuum radiation emitted from transition metals under ion bombardment

    International Nuclear Information System (INIS)

    El Boujlaidi, A.; Kaddouri, A.; Ait El Fqih, M.; Hammoum, K.; Aouchiche, H.

    2012-01-01

    Optical emission of transition metals has been studied during 5 keV Kr + ions bombardment within and without oxygen atmosphere in the colliding chamber. The observed spectra consist of a series of discrete lines superimposed on a broad continuum. Generally, the emission intensity was influenced by the presence of oxygen giving rise to transient effects as well as to an increase in the line intensity. The behaviours of spectral lines were successfully explained in term of electron-transfer process between the excited sputtered atom and the solid surface. In this work, we have focused our study on the continuous radiation emitted during ion bombardment. The experimental results suggest that the continuum emission depends on the nature of metal and very probably related to its electronic structure. The collective deactivation of 3d-shell electrons appears to play a role in the emission of this radiation. The observed enhancement in the presence of oxygen is probably due to a significant contribution of the oxide molecules. (authors)

  8. Magnetic resonance in medicine occupational exposure to static magnetic field and radiofrequency radiation

    International Nuclear Information System (INIS)

    Zivkovic, D.; Hrnjak, M.; Ivanovic, C.

    1997-01-01

    Medical personnel working with magnetic resonance imaging (MRI) devices could be exposed to static magnetic (M) field, time-varying M fields and radiofrequency (RF) radiation. The aim of work was to investigate the density of magnetic flux of static magnetic field and the power density of RF radiation which appear in the working environment around the 0.5 T MRI unit in one hospital. The density of magnetic flux of static magnetic field was measured with Hall Effect Gauss meter - Magnetech (Great Britain), and the power density of RF radiation was measured with broadband isotropic meter - The Narda Microwave Corp. (USA). The results of measurement show that the density of magnetic flux of static M field on working places are below threshold limit of exposure and the intensities of RF radiation are far below maximum permissible level. (author)

  9. Bill C-5, an act to amend the radiation emitting devices act

    International Nuclear Information System (INIS)

    1984-01-01

    This Act, entitled Bill C-5, allows for a series of amendments to the Radiation Emitting Devices Act. The amendments relate to regulations concerned with the sale, lease or import, labelling, advertising, packaging, safety standards and inspection of radiation emitting devices

  10. Clastogenic effects of radiofrequency radiations on chromosomes of Tradescantia

    International Nuclear Information System (INIS)

    Haider, Thomas; Kundi, Michael; Haider, Manfred; Knasmueller, Siegfried

    1994-01-01

    The clastogenicity of electromagnetic fields (EMF) has so far been studied only under laboratory conditions. We used the Tradescantia-micronucleus (Trad-MCN) bioassay in an in situ experiment to find out whether short-wave electromagnetic fields used for broadcasting (10-21 MHz) may show genotoxic effects. Plant cuttings bearing young flower buds were exposed (30 h) on both sides of a slewable curtain antenna (300/500 kW, 40-170 V/m) and 15 m (90 V/m) and 30 m (70 V/m) distant from a vertical cage antenna (100 kW) as well as at the neighbors living near the broadcasting station (200 m, 1-3 V/m). The exposure at both sides of the slewable curtain antenna was performed simultaneously within cages, one of the Faraday type shielding the field and one non-shielding mesh cage. Laboratory controls were maintained for comparison. Higher MCN frequencies than in laboratory controls were found for all exposure sites in the immediate vicinity of the antennae, where the exposure standards of the electric field strength of the International Radiation Protection Association (IRPA) were exceeded. The results at all exposure sites except one were statistically significant. Since the parallel exposure in a non-shielding and a shielding cage also revealed significant differences in MCN frequencies (the latter showing no significant differences from laboratory controls), the clastogenic effects are clearly attributable to the short-wave radiation from the antennae

  11. Does Occupational Exposure of Shahid Dastghieb International Airport Workers to Radiofrequency Radiation Affect Their Short Term Memory and Reaction Time?

    Directory of Open Access Journals (Sweden)

    Jarideh S.

    2015-05-01

    Full Text Available Background: Airport workers are continuously exposed to different levels of radiofrequency microwave (RF/MW radiation emitted by radar equipments. Radars are extensively used in military and aviation industries. Over the past several years, our lab has focused on the health effects of exposure to different sources of electromagnetic fields such as cellular phones, mobile base stations, mobile phone jammers, laptop computers, radars, dentistry cavitrons and MRI. The main goal of this study was to investigate if occupational exposure of Shahid Dastghieb international airport workers to radiofrequency radiation affects their short term memory and reaction time. Methods: Thirty two airport workers involved in duties at control and approach tower (21 males and 11 females, with the age range of 27-67 years old (mean age of 37.38, participated voluntary in this study. On the other hand, 29 workers (13 males, and 16 females whose offices were in the city with no exposure history to radar systems were also participated in this study as the control group. The employees’ reaction time and short term memory were analyzed using a standard visual reaction time (VRT test software and the modified Wechsler memory scale test, respectively. Results: The mean± SD values for the reaction times of the airport employees (N=32 and the control group (N=29 were 0.45±0.12 sec and 0.46±0.17 sec, respectively. Moreover, in the four subset tests; i.e. paired words, forward digit span, backward digit span and word recognition, the following points were obtained for the airport employees and the control group, respectively: (i pair words test: 28.00±13.13 and 32.07±11.65, (ii forward digit span: 8.38±1.40 and 9.03±1.32, (iii backward digit span: 5.54±1.87 and 6.31±1.46, and (iv word recognition: 5.73±2.36 and 6.50±1.93. These differences were not statistically significant. Conclusion: The occupational exposure of the employees to the RF radiation in Shahid

  12. Exposure to 1800 MHz radiofrequency electromagnetic radiation induces oxidative DNA base damage in a mouse spermatocyte-derived cell line.

    Science.gov (United States)

    Liu, Chuan; Duan, Weixia; Xu, Shangcheng; Chen, Chunhai; He, Mindi; Zhang, Lei; Yu, Zhengping; Zhou, Zhou

    2013-03-27

    Whether exposure to radiofrequency electromagnetic radiation (RF-EMR) emitted from mobile phones can induce DNA damage in male germ cells remains unclear. In this study, we conducted a 24h intermittent exposure (5 min on and 10 min off) of a mouse spermatocyte-derived GC-2 cell line to 1800 MHz Global System for Mobile Communication (GSM) signals in GSM-Talk mode at specific absorption rates (SAR) of 1 W/kg, 2 W/kg or 4 W/kg. Subsequently, through the use of formamidopyrimidine DNA glycosylase (FPG) in a modified comet assay, we determined that the extent of DNA migration was significantly increased at a SAR of 4 W/kg. Flow cytometry analysis demonstrated that levels of the DNA adduct 8-oxoguanine (8-oxoG) were also increased at a SAR of 4 W/kg. These increases were concomitant with similar increases in the generation of reactive oxygen species (ROS); these phenomena were mitigated by co-treatment with the antioxidant α-tocopherol. However, no detectable DNA strand breakage was observed by the alkaline comet assay. Taking together, these findings may imply the novel possibility that RF-EMR with insufficient energy for the direct induction of DNA strand breaks may produce genotoxicity through oxidative DNA base damage in male germ cells. Crown Copyright © 2013. Published by Elsevier Ireland Ltd. All rights reserved.

  13. The 2100MHz radiofrequency radiation of a 3G-mobile phone and the DNA oxidative damage in brain.

    Science.gov (United States)

    Sahin, Duygu; Ozgur, Elcin; Guler, Goknur; Tomruk, Arın; Unlu, Ilhan; Sepici-Dinçel, Aylin; Seyhan, Nesrin

    2016-09-01

    We aimed to evaluate the effect of 2100MHz radiofrequency radiation emitted by a generator, simulating a 3G-mobile phone on the brain of rats during 10 and 40 days of exposure. The female rats were randomly divided into four groups. Group I; exposed to 3G modulated 2100MHz RFR signal for 6h/day, 5 consecutive days/wk for 2 weeks, group II; control 10 days, were kept in an inactive exposure set-up for 6h/day, 5 consecutive days/wk for 2 weeks, group III; exposed to 3G modulated 2100MHz RFR signal for 6h/day, 5 consecutive days/wk for 8 weeks and group IV; control 40 days, were kept in an inactive exposure set-up for 6h/day, 5 consecutive days/wk for 8 weeks. After the genomic DNA content of brain was extracted, oxidative DNA damage (8-hydroxy-2'deoxyguanosine, pg/mL) and malondialdehyde (MDA, nmoL/g tissue) levels were determined. Our main finding was the increased oxidative DNA damage to brain after 10 days of exposure with the decreased oxidative DNA damage following 40 days of exposure compared to their control groups. Besides decreased lipid peroxidation end product, MDA, was observed after 40 days of exposure. The measured decreased quantities of damage during the 40 days of exposure could be the means of adapted and increased DNA repair mechanisms. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. ECG changes in factory workers exposed to 27.2  MHz radiofrequency radiation.

    Science.gov (United States)

    Chen, Qingsong; Xu, Guoyong; Lang, Li; Yang, Aichu; Li, Shilin; Yang, Liwen; Li, Chaolin; Huang, Hanlin; Li, Tao

    2013-05-01

    To research the effect of 27.2 MHz radiofrequency radiation on electrocardiograms (ECG), 225 female workers operating radiofrequency machines at a shoe factory were chosen as the exposure group and 100 female workers without exposure from the same factory were selected as the control group. The 6 min electric field strength that the female workers were exposed to was 64.0 ± 25.2 V/m (mean ± SD), which exceeded 61 V/m, the International Commission on Non-Ionizing Radiation Protection reference root mean square levels for occupational exposure. A statistical difference was observed between the exposed group and the control group in terms of the rate of sinus bradycardia (χ(2)  = 11.48, P = 0.003). When several known risk factors for cardiovascular disease were considered, including smoking, age, alcohol ingestion habit, and so on, the exposure duration was not an effective factor for ECG changes, sinus arrhythmia, or sinus bradycardia according to α = 0.05, while P = 0.052 for sinus arrhythmia was very close to 0.05. We did not find any statistical difference in heart rate, duration of the QRS wave (ventricular depolarization), or corrected QT intervals (between the start of the Q wave and end of the T wave) between the exposed and control groups. Occupational exposure to radiofrequency radiation was not found to be a cause of ECG changes after consideration of the confounding factors. Copyright © 2012 Wiley Periodicals, Inc.

  15. Radiofrequency Electromagnetic Radiation and Memory Performance: Sources of Uncertainty in Epidemiological Cohort Studies.

    Science.gov (United States)

    Brzozek, Christopher; Benke, Kurt K; Zeleke, Berihun M; Abramson, Michael J; Benke, Geza

    2018-03-26

    Uncertainty in experimental studies of exposure to radiation from mobile phones has in the past only been framed within the context of statistical variability. It is now becoming more apparent to researchers that epistemic or reducible uncertainties can also affect the total error in results. These uncertainties are derived from a wide range of sources including human error, such as data transcription, model structure, measurement and linguistic errors in communication. The issue of epistemic uncertainty is reviewed and interpreted in the context of the MoRPhEUS, ExPOSURE and HERMES cohort studies which investigate the effect of radiofrequency electromagnetic radiation from mobile phones on memory performance. Research into this field has found inconsistent results due to limitations from a range of epistemic sources. Potential analytic approaches are suggested based on quantification of epistemic error using Monte Carlo simulation. It is recommended that future studies investigating the relationship between radiofrequency electromagnetic radiation and memory performance pay more attention to treatment of epistemic uncertainties as well as further research into improving exposure assessment. Use of directed acyclic graphs is also encouraged to display the assumed covariate relationship.

  16. Radiofrequency Electromagnetic Radiation and Memory Performance: Sources of Uncertainty in Epidemiological Cohort Studies

    Directory of Open Access Journals (Sweden)

    Christopher Brzozek

    2018-03-01

    Full Text Available Uncertainty in experimental studies of exposure to radiation from mobile phones has in the past only been framed within the context of statistical variability. It is now becoming more apparent to researchers that epistemic or reducible uncertainties can also affect the total error in results. These uncertainties are derived from a wide range of sources including human error, such as data transcription, model structure, measurement and linguistic errors in communication. The issue of epistemic uncertainty is reviewed and interpreted in the context of the MoRPhEUS, ExPOSURE and HERMES cohort studies which investigate the effect of radiofrequency electromagnetic radiation from mobile phones on memory performance. Research into this field has found inconsistent results due to limitations from a range of epistemic sources. Potential analytic approaches are suggested based on quantification of epistemic error using Monte Carlo simulation. It is recommended that future studies investigating the relationship between radiofrequency electromagnetic radiation and memory performance pay more attention to treatment of epistemic uncertainties as well as further research into improving exposure assessment. Use of directed acyclic graphs is also encouraged to display the assumed covariate relationship.

  17. Radiofrequency field emitted by mobile phones and alteration of the blood-brain barrier: how strong is the experimental evidence?

    International Nuclear Information System (INIS)

    Lagroye, I.; Haro, E.; Billaudel, B.; Ruffie, G.; Poulletier de Gannes, F.; Taxile, M.; Laclau, M.; Veyret, B.; Leveque, P.

    2006-01-01

    Full text of publication follows: It is known that high power, thermal radiofrequency radiation (RFR) can alter the blood-brain barrier (BBB) permeability with a brain averaged specific absorption rate (BASAR) threshold evaluated at around 100 W/kg (1). Mobile communication technologies are using RFR with exposure guidelines for public local exposure at 2 W/kg, far lower than the threshold previously mentioned. However, in a paper recently published (2) the occurrence of BBB leakage and brain damage (presence of dark neurons) has been reported 50 days after a single 2-hour exposure of rats to a GSM-900 signal. In that investigation however, bias could have occurred as, for instance, exposed animals were mixed in terms of age (12- to 26-week old) and gender, while those differences were not taken into account in the analysis. Moreover, other groups have published contradictory results (3). Our group undertook a confirmation study of the Salford experiments within an international collaborative programme including technical improvements. Our study includes the detection of dark neurons, alteration of the permeability of the BBB and apoptosis 14 or 50 days after GSM-900 exposure. The exposure setup was the loop antenna that allows for head-only exposure. Five groups of 16 Fisher 344 rats (14 -week old) were exposed to GSM-900 during 2 hours at various SAR levels (0, 0.14 and 2.0 W/kg), or were used as cage control or positive controls. Positive controls were treated with kainic acid (10 mg/kg) or by cold injury (dry ice during 5 minutes). After exposure, rats were kept alive during 14 or 50 days to study brain damages. Then, they were anesthetized with urethane (i.p. 1.5 mg/kg), perfused with PBS and fixed with paraformaldehyde 4% (PAF 4%). Brains were extracted and put in cold PAF 4% during the following night, then placed in cold sucrose 20% during 2-3 days, frozen with isopentane and placed at -80 deg. C. Coding was done on brains. Frozen brains were cut in 3

  18. Radiofrequency field emitted by mobile phones and alteration of the blood-brain barrier: how strong is the experimental evidence?

    Energy Technology Data Exchange (ETDEWEB)

    Lagroye, I.; Haro, E.; Billaudel, B.; Ruffie, G.; Poulletier de Gannes, F.; Taxile, M.; Laclau, M.; Veyret, B. [PIOM/UMR 5501 and Bioelectromagnetics laboratory/EPHE, ENSCPB, 33607 Pessac, (France); Leveque, P. [IRCOM, CNRS UMR 6615, Limoges (France)

    2006-07-01

    Full text of publication follows: It is known that high power, thermal radiofrequency radiation (RFR) can alter the blood-brain barrier (BBB) permeability with a brain averaged specific absorption rate (BASAR) threshold evaluated at around 100 W/kg (1). Mobile communication technologies are using RFR with exposure guidelines for public local exposure at 2 W/kg, far lower than the threshold previously mentioned. However, in a paper recently published (2) the occurrence of BBB leakage and brain damage (presence of dark neurons) has been reported 50 days after a single 2-hour exposure of rats to a GSM-900 signal. In that investigation however, bias could have occurred as, for instance, exposed animals were mixed in terms of age (12- to 26-week old) and gender, while those differences were not taken into account in the analysis. Moreover, other groups have published contradictory results (3). Our group undertook a confirmation study of the Salford experiments within an international collaborative programme including technical improvements. Our study includes the detection of dark neurons, alteration of the permeability of the BBB and apoptosis 14 or 50 days after GSM-900 exposure. The exposure setup was the loop antenna that allows for head-only exposure. Five groups of 16 Fisher 344 rats (14 -week old) were exposed to GSM-900 during 2 hours at various SAR levels (0, 0.14 and 2.0 W/kg), or were used as cage control or positive controls. Positive controls were treated with kainic acid (10 mg/kg) or by cold injury (dry ice during 5 minutes). After exposure, rats were kept alive during 14 or 50 days to study brain damages. Then, they were anesthetized with urethane (i.p. 1.5 mg/kg), perfused with PBS and fixed with paraformaldehyde 4% (PAF 4%). Brains were extracted and put in cold PAF 4% during the following night, then placed in cold sucrose 20% during 2-3 days, frozen with isopentane and placed at -80 deg. C. Coding was done on brains. Frozen brains were cut in 3

  19. Low power radiofrequency electromagnetic radiation for the treatment of pain due to osteoarthritis of the knee

    Directory of Open Access Journals (Sweden)

    U. Santosuosso

    2011-09-01

    Full Text Available Different techniques have been used in some rheumatic diseases to induce a therapeutic effect by heating deep tissues. These techniques are commonly known as ‘thermotherapy’ (1-4. It should be observed that adequate heating of deep tissues cannot be obtained by conduction or convection of heat because the skin and subcutaneous fat are good thermal insulators and because heating is reduced by blood flow in superficial vessels. Heating of deep tissues can instead be obtained by conversion of other forms of energy into heat. Conversion heat is generated by different types of radiations absorbed by deep tissues: when radiation interacts with tissues, some energy is converted into heat. High power radiofrequency electromagnetic radiation (RF, which produces strong thermal energy, has been widely applied in medicine for ablative procedures (5-7.

  20. Outdoor radiofrequency radiation levels in the West Bank-Palestine.

    Science.gov (United States)

    Lahham, Adnan; Hammash, Alaa

    2012-05-01

    This work presents the results of exposure levels to radio frequency (RF) emission from different sources in the environment of the West Bank-Palestine. These RF emitters include FM and TV broadcasting stations and mobile phone base stations. Power densities were measured at 65 locations distributed over the West Bank area. These locations include mainly centres of the major cities. Also a 24 h activity level was investigated for a mobile phone base station to determine the maximum activity level for this kind of RF emitters. All measurements were conducted at a height of 1.7 m above ground level using hand held Narda SRM 3000 spectrum analyzer with isotropic antenna capable of collecting RF signals in the frequency band from 75 MHz to 3 GHz. The average value of power density resulted from FM radio broadcasting in all investigated locations was 0.148 μW cm(-2), from TV broadcasting was 0.007 μW cm(-2) and from mobile phone base station was 0.089 μW cm(-2). The maximum total exposure evaluated at any location was 3.86 μW cm(-2). The corresponding exposure quotient calculated for this site was 0.02. This value is well below unity indicating compliance with the International Commission on non-ionising Radiation protection guidelines. Contributions from all relevant RF sources to the total exposure were evaluated and found to be ~62 % from FM radio, 3 % for TV broadcasting and 35 % from mobile phone base stations. The average total exposure from all investigated RF sources was 0.37 μW cm(-2).

  1. Outdoor radiofrequency radiation levels in the West Bank-palestine

    International Nuclear Information System (INIS)

    Lahham, A.; Hammash, A.

    2012-01-01

    This work presents the results of exposure levels to radio frequency (RF) emission from different sources in the environment of the West Bank-Palestine. These RF emitters include FM and TV broadcasting stations and mobile phone base stations. Power densities were measured at 65 locations distributed over the West Bank area. These locations include mainly centres of the major cities. Also a 24 h activity level was investigated for a mobile phone base station to determine the maximum activity level for this kind of RF emitters. All measurements were conducted at a height of 1.7 m above ground level using hand held Narda SRM 3000 spectrum analyzer with isotropic antenna capable of collecting RF signals in the frequency band from 75 MHz to 3 GHz. The average value of power density resulted from FM radio broadcasting in all investigated locations was 0.148 μW cm -2 , from TV broadcasting was 0.007 μW cm -2 and from mobile phone base station was 0.089 μW cm -2 . The maximum total exposure evaluated at any location was 3.86 μW cm -2 . The corresponding exposure quotient calculated for this site was 0.02. This value is well below unity indicating compliance with the International Commission on non-ionising Radiation protection guidelines. Contributions from all relevant RF sources to the total exposure were evaluated and found to be ∼62 % from FM radio, 3 % for TV broadcasting and 35 % from mobile phone base stations. The average total exposure from all investigated RF sources was 0.37 μW cm -2 . (authors)

  2. Behavior and memory evaluation of Wistar rats exposed to 1·8 GHz radiofrequency electromagnetic radiation.

    Science.gov (United States)

    Júnior, Luiz Carlos de Caires; Guimarães, Ernesto da Silveira Goulart; Musso, Camila Manso; Stabler, Collin Turner; Garcia, Raúl Marcel González; Mourão-Júnior, Carlos Alberto; Andreazzi, Ana Eliza

    2014-09-01

    The development of communication systems has brought great social and economic benefits to society. As mobile phone use has become widespread, concerns have emerged regarding the potential adverse effects of radiofrequency electromagnetic radiation (RF-EMR) used by these devices. To verify potential effects of mobile phone radiation on the central nervous system (CNS) in an animal model. Male Wistar rats (60 days old) were exposed to RF-EMR from a Global System for Mobile (GSM) cell phone (1·8 GHz) for 3 days. At the end of the exposure, the following behavioral tests were performed: open field and object recognition. Our results showed that exposed animals did not present anxiety patterns or working memory impairment, but stress behavior actions were observed. Given the results of the present study, we speculate that RF-EMR does not promote CNS impairment, but suggest that it may lead to stressful behavioral patterns.

  3. Assessment of radiofrequency radiation within the vicinity of some GSM base stations in Ghana

    International Nuclear Information System (INIS)

    Deatanyah, P.; Amoako, J. K.; Fletcher, J. J.; Asiedu, G. O.; Adjei, D. N.; Dwapanyin, G. O.; Amoatey, E. A.

    2012-01-01

    A radiofrequency (RF) electromagnetic radiation safety survey had been carried out at public access points in 46 towns with 76 Global Systems for Mobile communication cell sites in two major cities in Ghana. The objective was to determine the levels of RF field in residential areas, schools and market places, and compare the measured results with the guidelines set by the International Commission of Non-Ionising Radiation (ICNIRP). Measurements were made with log-periodic antenna coupled with spectrum analyzer. The results varied from 0.85 to 1.07 mW m -2 and 0.78 to 1.19 mW m -2 for the transmission frequencies of 900 and 1800 MHz, respectively. The result generally shows a compliance with the ICNIRP limit of 0.024 % but was 108 times higher than a similar survey carried out in Ghana 2 y ago. (authors)

  4. An evaluation of safety guidelines to restrict exposure to stray radiofrequency radiation from short-wave diathermy units

    Energy Technology Data Exchange (ETDEWEB)

    Shields, Nora [School of Physiotherapy, La Trobe University, Victoria 3086 (Australia); O' Hare, Neil [Department of Medical Physics and Bioengineering, St James' s Hospital, Dublin 8 (Ireland); Gormley, John [School of Physiotherapy, Trinity College Dublin, Trinity Centre for Health Sciences, St James' s Hospital, Dublin 8 (Ireland)

    2004-07-07

    Short-wave diathermy (SWD), a form of radiofrequency radiation used therapeutically by physiotherapists, may be applied in continuous (CSWD) or pulsed (PSWD) mode using either capacitive or inductive methods. Stray radiation emitted by these units may exceed exposure guidelines close to the equipment. Discrepant guidelines exist on a safe distance from an operating unit for operators and other personnel. Stray electric (E-field) and magnetic (H-field) field strengths from 10 SWD units in six departments were examined using a PMM 8053 meter and two isotropic probes (EP-330, HP-032). A 5 l saline phantom completed the patient circuit. Measurements were recorded in eight directions between 0.5 m and 2 m at hip and eye levels while the units operated at maximum output and data compared to current guidelines. Results found stray fields from capacitive CSWD fell below operator limits at 2 m (E-field 4.8-39.8 V/m; H-field 0.015-0.072 A/m) and at 1 m for inductive CSWD (E-field 0-36 V/m; H-field 0.01-0.065 A/m). Capacitive PSWD fields fell below the limits at 1.5 m (E-field 1.2-19.9 V/m; H-field 0.002-0.045 A/m) and at 1m for inductive PSWD (E-field 0.7-4.0 V/m; H-field 0.009-0.03 A/m). An extra 0.5 m was required before fields fell below the guidelines for other personnel. These results demonstrate, under a worst case scenario, emissions from SWD exceed the guidelines for operators at distances currently recommended as safe. Future guidelines should include recommendations for personnel other than physiotherapists.

  5. An evaluation of safety guidelines to restrict exposure to stray radiofrequency radiation from short-wave diathermy units

    International Nuclear Information System (INIS)

    Shields, Nora; O'Hare, Neil; Gormley, John

    2004-01-01

    Short-wave diathermy (SWD), a form of radiofrequency radiation used therapeutically by physiotherapists, may be applied in continuous (CSWD) or pulsed (PSWD) mode using either capacitive or inductive methods. Stray radiation emitted by these units may exceed exposure guidelines close to the equipment. Discrepant guidelines exist on a safe distance from an operating unit for operators and other personnel. Stray electric (E-field) and magnetic (H-field) field strengths from 10 SWD units in six departments were examined using a PMM 8053 meter and two isotropic probes (EP-330, HP-032). A 5 l saline phantom completed the patient circuit. Measurements were recorded in eight directions between 0.5 m and 2 m at hip and eye levels while the units operated at maximum output and data compared to current guidelines. Results found stray fields from capacitive CSWD fell below operator limits at 2 m (E-field 4.8-39.8 V/m; H-field 0.015-0.072 A/m) and at 1 m for inductive CSWD (E-field 0-36 V/m; H-field 0.01-0.065 A/m). Capacitive PSWD fields fell below the limits at 1.5 m (E-field 1.2-19.9 V/m; H-field 0.002-0.045 A/m) and at 1m for inductive PSWD (E-field 0.7-4.0 V/m; H-field 0.009-0.03 A/m). An extra 0.5 m was required before fields fell below the guidelines for other personnel. These results demonstrate, under a worst case scenario, emissions from SWD exceed the guidelines for operators at distances currently recommended as safe. Future guidelines should include recommendations for personnel other than physiotherapists

  6. Radiation exposure to patients and operator during radiofrequency ablation for supraventricular tachycardia

    International Nuclear Information System (INIS)

    Kovoor, P.; Ricciardello, M.; Collins, L.; Uther, J.B.; Ross, D.L.

    1995-01-01

    Radiofrequency (RF) ablation has become the primary method of treatment for supraventricular tachycardia and often requires prolonged fluoroscopy times. The aim of this study was to quantitate radiation exposure to patient and operator during RF ablation for supra- ventricular tachycardia. Thermoluminescent dosemeters were used to monitor radiation at seven sites. Positions were: patient's thyroid, left scapula, T9 vertebra, right scapula and L4-L5 vertebra and the operator's thyroid and left hand. Monitoring was performed during 22 procedures. Of the patients studied 10 (45%) had atrioventricular junctional re-entry tachycardia (AVJRT) and 12 (55%) had accessory pathway tachycardia. The median fluoroscopy times (minutes) and inter-quartile ranges were 46 (39-65) for AVJRT, 55 (52-60) for left free wall accessory pathway (LFW), 107 (89-140) for septal and 166 (128-176) for RFW pathways. The mean radiation doses (mGy) to the chest wall were 50 for AVJRT, 47 for LFW, 87 for septal and 151 for RFW pathways. The mean radiation to the chest wall of the patient per case was found to be 3.9 times that reported for diagnostic cardiac catheterisation and 1.5 times that reported for angioplasty. It is concluded that radiofrequency ablation is associated with significant irradiation of the patient and operator. All precautions should be taken to decrease this exposure. If eye irradiation is assumed to be equal to that to the thyroid, more than 45 procedures per month by a single operator (using ceiling-suspended lead glass shielding) may result in exceeding the recommended dose limit to the eye. 32 refs., 3 tabs

  7. World Health Organization, radiofrequency radiation and health - a hard nut to crack (Review).

    Science.gov (United States)

    Hardell, Lennart

    2017-08-01

    In May 2011 the International Agency for Research on Cancer (IARC) evaluated cancer risks from radiofrequency (RF) radiation. Human epidemiological studies gave evidence of increased risk for glioma and acoustic neuroma. RF radiation was classified as Group 2B, a possible human carcinogen. Further epidemiological, animal and mechanistic studies have strengthened the association. In spite of this, in most countries little or nothing has been done to reduce exposure and educate people on health hazards from RF radiation. On the contrary ambient levels have increased. In 2014 the WHO launched a draft of a Monograph on RF fields and health for public comments. It turned out that five of the six members of the Core Group in charge of the draft are affiliated with International Commission on Non-Ionizing Radiation Protection (ICNIRP), an industry loyal NGO, and thus have a serious conflict of interest. Just as by ICNIRP, evaluation of non-thermal biological effects from RF radiation are dismissed as scientific evidence of adverse health effects in the Monograph. This has provoked many comments sent to the WHO. However, at a meeting on March 3, 2017 at the WHO Geneva office it was stated that the WHO has no intention to change the Core Group.

  8. Radiofrequency radiation at Stockholm Central Railway Station in Sweden and some medical aspects on public exposure to RF fields

    OpenAIRE

    Hardell, Lennart; Koppel, Tarmo; Carlberg, Michael; Ahonen, Mikko; Hedendahl, Lena

    2016-01-01

    The Stockholm Central Railway Station in Sweden was investigated for public radiofrequency (RF) radiation exposure. The exposimeter EME Spy 200 was used to collect the RF exposure data across the railway station. The exposimeter covers 20 different radiofrequency bands from 88 to 5,850 MHz. In total 1,669 data points were recorded. The median value for total exposure was 921 ?W/m2 (or 0.092 ?W/cm2; 1 ?W/m2=0.0001 ?W/cm2) with some outliers over 95,544 ?W/m2 (6 V/m, upper detection limit). The...

  9. Induction of adaptive response in human blood lymphocytes exposed to radiofrequency radiation.

    Science.gov (United States)

    Sannino, Anna; Sarti, Maurizio; Reddy, Siddharth B; Prihoda, Thomas J; Vijayalaxmi; Scarfì, Maria Rosaria

    2009-06-01

    The incidence of micronuclei was evaluated to assess the induction of an adaptive response to non-ionizing radiofrequency (RF) radiation in peripheral blood lymphocytes collected from five different human volunteers. After stimulation with phytohemagglutinin for 24 h, the cells were exposed to an adaptive dose of 900 MHz RF radiation used for mobile communications (at a peak specific absorption rate of 10 W/kg) for 20 h and then challenged with a single genotoxic dose of mitomycin C (100 ng/ml) at 48 h. Lymphocytes were collected at 72 h to examine the frequency of micronuclei in cytokinesis-blocked binucleated cells. Cells collected from four donors exhibited the induction of adaptive response (i.e., responders). Lymphocytes that were pre-exposed to 900 MHz RF radiation had a significantly decreased incidence of micronuclei induced by the challenge dose of mitomycin C compared to those that were not pre-exposed to 900 MHz RF radiation. These preliminary results suggested that the adaptive response can be induced in cells exposed to non-ionizing radiation. A similar phenomenon has been reported in cells as well as in animals exposed to ionizing radiation in several earlier studies. However, induction of adaptive response was not observed in the remaining donor (i.e., non-responder). The incidence of micronuclei induced by the challenge dose of mitomycin C was not significantly different between the cells that were pre-exposed and unexposed to 900 MHz RF radiation. Thus the overall data indicated the existence of heterogeneity in the induction of an adaptive response between individuals exposed to RF radiation and showed that the less time-consuming micronucleus assay can be used to determine whether an individual is a responder or non-responder.

  10. Assessment of Radio-Frequency Radiation Exposure Level from Selected Mobile Base Stations (MBS) in Lokoja, Kogi State, Nigeria

    OpenAIRE

    Nwankwo, U. J. Victor; Jibiri, N. N.; Dada, S. S.; Onugba, A. A.; Ushie, P.

    2012-01-01

    The acquisition and use of mobile phone is tremendously increasing especially in developing countries, but not without a concern. The greater concern among the public is principally over the proximity of mobile base stations (MBS) to residential areas rather than the use of handsets. In this paper, we present an assessment of Radio-Frequency (RF) radiation exposure level measurements and analysis of radiation power density (in W/sq m) from mobile base stations relative to radial distance (in ...

  11. Combined Effect of Ambient Temperature with Radiofrequency Electromagnetic Radiation in Rabbit

    International Nuclear Information System (INIS)

    Kim, Jin Kyu; Choi, Dae Seong; Komarova, Ludmila N.; Petin, Vladislav G.

    2010-01-01

    There has been an increasing interest in synergistic effects observed after combined action of various agents. Many studies have shown that numerous physical and chemical agents combined with hyperthermia can interact in a synergistic manner when the effect produced by both agents used in combination exceeded the expected results from simple summation of the every effect produced by heat and the particular agent. I t was found that ambient temperature had a profound effect on the thermoregulatory responses to radiofrequency electromagnetic radiation (RFR) in various animals and humans. An extensive quantitative investigation of synergistic interaction of ambient temperature and microwaves has been published for rabbit heating. I t would be of interest to estimate whether or not the general features of the combined action revealed with unicellular organisms can be expressed for animals exposed to microwave power combined with a higher environmental temperature.

  12. Intraoperative radio-frequency capacitive hyperthermia and radiation therapy for unresectable pancreatic cancer

    International Nuclear Information System (INIS)

    Nakazawa, M.; Yamashita, T.; Hashida, I.

    1988-01-01

    The authors have initiated intraoperative radiation therapy (IORT) and intraoperative radio-frequency capacitive hyperthermia (IOHT) for unresectable pancreatic cancer. After gastric (corpus) resection, IORT and IOHT were conducted and gastro-duodenostomy was performed IORT was delivered with 12 meV electron (25 Gy) and 10 MV Linac x-ray (7.5 Gy). IOHT was done with 13.56 MHz capacitive equipment aiming 43 0 C for over 30 min along with concurrent administration of 500 mg 5-FU. Five cases were heated by the conventional method and two additional cases were heated with a newly fabricated applicator. Attained temperatures monitored directly from tumor were 38.5 0 C-44.3 0 C (over 43 0 C in four cases, 40 0 C in one case, and below 40 0 C in two cass.) Pain relief was achieved in most cases. Using the new applicators, the authors could avoid unexpected hot spots and insufficient heating

  13. Radiofrequency radiation: safe working practices in the Royal Australian Air Force

    International Nuclear Information System (INIS)

    Joyner, K.H.; Stone, K.R.

    1988-01-01

    The Royal Australian Air Force (RAAF) has long recognised the value of its work force and the need to preserve their health and wellbeing to achieve operational objectives. The Directorate of Air Force Safety (DAFS) is required by the Chief of the Air Staff to take all measures possible to prevent accidents and incidents in the RAAF, under the provisions of the Defence Instruction, 'Air Force Safety and Occupational Health Policy'. Consequently, the RAAF has exercised a pragmatic approach to radiofrequency radiation (RFR) and has always adopted and implemented strict exposure standards. DAFS receives technical advice on RFR from the Directorate of Telecommunications Engineering (DTELENG) and on occupational health from the Directorate General of Air Force Health Services (DGAFHS)

  14. Effects of GSM modulated radio-frequency electromagnetic radiation on permeability of blood-brain barrier in male & female rats.

    Science.gov (United States)

    Sırav, Bahriye; Seyhan, Nesrin

    2016-09-01

    With the increased use of mobile phones, their biological and health effects have become more important. Usage of mobile phones near the head increases the possibility of effects on brain tissue. This study was designed to investigate the possible effects of pulse modulated 900MHz and 1800MHz radio-frequency radiation on the permeability of blood-brain barrier of rats. Study was performed with 6 groups of young adult male and female wistar albino rats. The permeability of blood-brain barrier to intravenously injected evans blue dye was quantitatively examined for both control and radio-frequency radiarion exposed groups. For male groups; Evans blue content in the whole brain was found to be 0.08±0.01mg% in the control, 0.13±0.03mg% in 900MHz exposed and 0.26±0.05mg% in 1800MHz exposed animals. In both male radio-frequency radiation exposed groups, the permeability of blood-brain barrier found to be increased with respect to the controls (pradiation exposure was found more effective on the male animals (p0.01). However 900MHz pulse modulated radio-frequency exposure was found effective on the permeability of blood-brain barrier of female animals. Results have shown that 20min pulse modulated radio-frequency radiation exposure of 900MHz and 1800MHz induces an effect and increases the permeability of blood-brain barrier of male rats. For females, 900MHz was found effective and it could be concluded that this result may due to the physiological differences between female and male animals. The results of this study suggest that mobile phone radation could lead to increase the permeability of blood-brain barrier under non-thermal exposure levels. More studies are needed to demonstrate the mechanisms of that breakdown. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Evaluation of cellular effects of pulsed and continuous wave radiofrequency radiation

    International Nuclear Information System (INIS)

    Pavicic, Ivan; Trosic, Ivancica

    2008-01-01

    proliferation was determined by cell counts for each hour of exposure during five post-exposure days. To identify colony-forming ability, cells were cultivated in concentration of 40 cells/mL and incubated as above. Colony forming ability was defined by colony counts on the 7 th post-exposure day for each hour of exposure. In comparison to the controls, growth curve shows that proliferation ability of CW irradiated cells significantly decrease after 3 hours of exposure on the 3rd post-exposure day. PW exposed cell samples showed significant decrease after 3 hours of exposure on the 2nd and 3rd post-exposure day. CFA of CW and PW exposed cells did not significantly differ from the matched controls. The applied radiofrequency fields have shown similar effect on cell culture growth and CFA. Under the comparable conditions of exposure, pulsed radiofrequency radiation can be more effective in producing biological effects than continuous radiofrequency radiation. (author)

  16. Estimating the Infrared Radiation Wavelength Emitted by a Remote Control Device Using a Digital Camera

    Science.gov (United States)

    Catelli, Francisco; Giovannini, Odilon; Bolzan, Vicente Dall Agnol

    2011-01-01

    The interference fringes produced by a diffraction grating illuminated with radiation from a TV remote control and a red laser beam are, simultaneously, captured by a digital camera. Based on an image with two interference patterns, an estimate of the infrared radiation wavelength emitted by a TV remote control is made. (Contains 4 figures.)

  17. Risk of Ionizing Radiation in Women of Childbearing Age undergoing Radiofrequency Ablation

    International Nuclear Information System (INIS)

    Lima, Gustavo Glotz de; Gomes, Daniel Garcia; Gensas, Caroline Saltz; Simão, Mariana Fernandez; Rios, Matheus N.; Pires, Leonardo Martins; Kruse, Marcelo Lapa; Leiria, Tiago Luiz Luz

    2013-01-01

    The International Commission of Radiology recommends a pregnancy screening test to all female patients of childbearing age who will undergo a radiological study. Radiation is known to be teratogenic and its effect is cumulative. The teratogenic potential starts at doses close to those used during these procedures. The prevalence of positive pregnancy tests in patients undergoing electrophysiological studies and/or catheter ablation in our midst is unknown. To evaluate the prevalence of positive pregnancy tests in female patients referred for electrophysiological study and/or radiofrequency ablation. Cross-sectional study analyzing 2,966 patients undergoing electrophysiological study and/or catheter ablation, from June 1997 to February 2013, in the Institute of Cardiology of Rio Grande do Sul. A total of 1490 procedures were performed in women, of whom 769 were of childbearing age. All patients were screened with a pregnancy test on the day before the procedure. Three patients tested positive, and were therefore unable to undergo the procedure. The prevalence observed was 3.9 cases per 1,000 women of childbearing age. Because of their safety and low cost, pregnancy screening tests are indicated for all women of childbearing age undergoing radiological studies, since the degree of ionizing radiation needed for these procedures is very close to the threshold for teratogenicity, especially in the first trimester, when the signs of pregnancy are not evident

  18. Risk of Ionizing Radiation in Women of Childbearing Age undergoing Radiofrequency Ablation

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Gustavo Glotz de, E-mail: gglima.pesquisa@gmail.com; Gomes, Daniel Garcia; Gensas, Caroline Saltz; Simão, Mariana Fernandez; Rios, Matheus N.; Pires, Leonardo Martins; Kruse, Marcelo Lapa; Leiria, Tiago Luiz Luz [Instituto de Cardiologia, Fundação Universitária de Cardiologia, Porto Alegre, RS (Brazil)

    2013-11-15

    The International Commission of Radiology recommends a pregnancy screening test to all female patients of childbearing age who will undergo a radiological study. Radiation is known to be teratogenic and its effect is cumulative. The teratogenic potential starts at doses close to those used during these procedures. The prevalence of positive pregnancy tests in patients undergoing electrophysiological studies and/or catheter ablation in our midst is unknown. To evaluate the prevalence of positive pregnancy tests in female patients referred for electrophysiological study and/or radiofrequency ablation. Cross-sectional study analyzing 2,966 patients undergoing electrophysiological study and/or catheter ablation, from June 1997 to February 2013, in the Institute of Cardiology of Rio Grande do Sul. A total of 1490 procedures were performed in women, of whom 769 were of childbearing age. All patients were screened with a pregnancy test on the day before the procedure. Three patients tested positive, and were therefore unable to undergo the procedure. The prevalence observed was 3.9 cases per 1,000 women of childbearing age. Because of their safety and low cost, pregnancy screening tests are indicated for all women of childbearing age undergoing radiological studies, since the degree of ionizing radiation needed for these procedures is very close to the threshold for teratogenicity, especially in the first trimester, when the signs of pregnancy are not evident.

  19. Analysis of emotionality and locomotion in radio-frequency electromagnetic radiation exposed rats.

    Science.gov (United States)

    Narayanan, Sareesh Naduvil; Kumar, Raju Suresh; Paval, Jaijesh; Kedage, Vivekananda; Bhat, M Shankaranarayana; Nayak, Satheesha; Bhat, P Gopalakrishna

    2013-07-01

    In the current study the modulatory role of mobile phone radio-frequency electromagnetic radiation (RF-EMR) on emotionality and locomotion was evaluated in adolescent rats. Male albino Wistar rats (6-8 weeks old) were randomly assigned into the following groups having 12 animals in each group. Group I (Control): they remained in the home cage throughout the experimental period. Group II (Sham exposed): they were exposed to mobile phone in switch-off mode for 28 days, and Group III (RF-EMR exposed): they were exposed to RF-EMR (900 MHz) from an active GSM (Global system for mobile communications) mobile phone with a peak power density of 146.60 μW/cm(2) for 28 days. On 29th day, the animals were tested for emotionality and locomotion. Elevated plus maze (EPM) test revealed that, percentage of entries into the open arm, percentage of time spent on the open arm and distance travelled on the open arm were significantly reduced in the RF-EMR exposed rats. Rearing frequency and grooming frequency were also decreased in the RF-EMR exposed rats. Defecation boli count during the EPM test was more with the RF-EMR group. No statistically significant difference was found in total distance travelled, total arm entries, percentage of closed arm entries and parallelism index in the RF-EMR exposed rats compared to controls. Results indicate that mobile phone radiation could affect the emotionality of rats without affecting the general locomotion.

  20. an assessment of ultraviolet radiation components of light emitted ...

    African Journals Online (AJOL)

    Dr

    therefore high for exposure limits of 8 hours for UV-B and UV-C and the 16 minutes for UV-A. The investigation ... has become particularly interesting as the ozone layer ... THEORY. Ultraviolet (UV) light is an electromagnetic radiation with a ...

  1. Stress and Fatigue in Operators Under Radiofrequency Electromagnetic Radiation and Shift Work

    Directory of Open Access Journals (Sweden)

    Vangelova K.

    2014-12-01

    Full Text Available The aim was to study the effect of radiofrequency electromagnetic radiation (EMR on stress indices, health complaints and fatigue of operators working fast-rotating extended shifts. Working conditions, job content, job control, social support, health complaints and fatigue were followed in 220 operators, 110 exposed to EMR and 110 control operators, matched by age and sex. The EMR was measured and time-weighted average (TWA was calculated. The excretion rates of stress hormones cortisol, adrenaline and noradrenaline were followed during the extended shifts in 36 operators, working at different levels of exposure and 24-hour exposure was calculated. The exposed group pointed more problems with the working conditions, including EMR, noise, currents and risk of accidents, more health complaints and higher level of fatigue. The most common health complaints were mental and physical exhaustion after work, pains in the chest, musculoskeletal complaints, headache, and apathy. High level EMR exposure (TWAmean = 3.10 μW/cm2, TWAmax = 137.00 μW/cm2 significantly increased the 24-hour excretion of cortisol and noradrenaline, whereas the increase of adrenaline excretion did not reach significance, as well as hormone excretion rates under low level exposure (TWAmean = 1.89 μW/cm2, TWAmax = 5.24 μW/cm2. In conclusion, higher number of health complaints, higher stress hormone excretion rates and fatigue were found in operators under EMR.

  2. Most cancer in firefighters is due to radio-frequency radiation exposure not inhaled carcinogens.

    Science.gov (United States)

    Milham, S

    2009-11-01

    Recent reviews and reports of cancer incidence and mortality in firefighters conclude that they are at an increased risk of a number of cancers. These include leukemia, multiple myeloma, non-Hodgkin's lymphoma, male breast cancer, malignant melanoma, and cancers of the brain, stomach, colon, rectum, prostate, urinary bladder, testes, and thyroid. Firefighters are exposed to a long list of recognized or probable carcinogens in combustion products and the presumed route of exposure to these carcinogens is by inhalation. Curiously, respiratory system cancers and diseases are usually not increased in firefighters as they are in workers exposed to known inhaled carcinogens. The list of cancers with increased risk in firefighters strongly overlaps the list of cancers at increased risk in workers exposed to electromagnetic fields (EMF) and radiofrequency radiation (RFR). Firefighters have increased exposure to RFR in the course of their work, from the mobile two-way radio communications devices which they routinely use while fighting fires, and at times from firehouse and fire vehicle radio transmitters. I suggest that some of the increased cancer risk in firefighters is caused by RFR exposure, and is therefore preventable. The precautionary principle should be applied to reduce the risk of cancer in firefighters, and workman's compensation rules will necessarily need to be modified.

  3. Measurements of nonionizing radiation emitted from microwave oven

    International Nuclear Information System (INIS)

    Elnour, Yassir Elnour Osman

    2014-05-01

    There is an increase in the usage of microwave oven which is used electromagnetic radiation in the microwave range, which believed to be harmful to human health. The measurements were taken at distance of range(0-100) cm from the microwave oven. The study concluded that the risk possibility of the radiation increases at high mode. We measured the power density, magnetic field and signal strength of microwave oven using the SPECTRAN high frequency (HF-6080) detector. The experimental results of power density were found to be (3.78-208000) nW/m 2 and magnetic field is (0.001-0.744) mA/m. These values are less than the exposure limits recommended. (author)

  4. The protective effect of autophagy on mouse spermatocyte derived cells exposure to 1800MHz radiofrequency electromagnetic radiation.

    Science.gov (United States)

    Liu, Kaijun; Zhang, Guowei; Wang, Zhi; Liu, Yong; Dong, Jianyun; Dong, Xiaomei; Liu, Jinyi; Cao, Jia; Ao, Lin; Zhang, Shaoxiang

    2014-08-04

    The increasing exposure to radiofrequency (RF) radiation emitted from mobile phone use has raised public concern regarding the biological effects of RF exposure on the male reproductive system. Autophagy contributes to maintaining intracellular homeostasis under environmental stress. To clarify whether RF exposure could induce autophagy in the spermatocyte, mouse spermatocyte-derived cells (GC-2) were exposed to 1800MHz Global System for Mobile Communication (GSM) signals in GSM-Talk mode at specific absorption rate (SAR) values of 1w/kg, 2w/kg or 4w/kg for 24h, respectively. The results indicated that the expression of LC3-II increased in a dose- and time-dependent manner with RF exposure, and showed a significant change at the SAR value of 4w/kg. The autophagosome formation and the occurrence of autophagy were further confirmed by GFP-LC3 transient transfection assay and transmission electron microscopy (TEM) analysis. Furthermore, the conversion of LC3-I to LC3-II was enhanced by co-treatment with Chloroquine (CQ), indicating autophagic flux could be enhanced by RF exposure. Intracellular ROS levels significantly increased in a dose- and time-dependent manner after cells were exposed to RF. Pretreatment with anti-oxidative NAC obviously decreased the conversion of LC3-I to LC3-II and attenuated the degradation of p62 induced by RF exposure. Meanwhile, phosphorylated extracellular-signal-regulated kinase (ERK) significantly increased after RF exposure at the SAR value of 2w/kg and 4w/kg. Moreover, we observed that RF exposure did not increase the percentage of apoptotic cells, but inhibition of autophagy could increase the percentage of apoptotic cells. These findings suggested that autophagy flux could be enhanced by 1800MHz GSM exposure (4w/kg), which is mediated by ROS generation. Autophagy may play an important role in preventing cells from apoptotic cell death under RF exposure stress. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  5. Radiofrequency Neurotomy

    Science.gov (United States)

    ... your specific symptoms. What you can expect Before radiofrequency neurotomy Let your doctor know if you take ... tobacco products the day of your procedure. During radiofrequency neurotomy Radiofrequency neurotomy is an outpatient procedure, so ...

  6. Non-radiative recombination losses in polymer light-emitting diodes

    NARCIS (Netherlands)

    Kuik, M.; Koster, L. J. A.; Dijkstra, A. G.; Wetzelaer, G. A. H.; Blom, P. W. M.

    We present a quantitative analysis of the loss of electroluminescence in light-emitting diodes (LEDs) based on poly[2-methoxy-5-(2'-ethylhexyloxy)-p-phenylenevinylene] (MEH-PPV) due to the combination of non-radiative trap-assisted recombination and exciton quenching at the metallic cathode. It is

  7. Effect of Exposure to 900 MHz GSM Mobile Phone Radiofrequency Radiation on Estrogen Receptor Methylation Status in Colon Cells of Male Sprague Dawley Rats

    Science.gov (United States)

    Mokarram, P.; Sheikhi, M.; Mortazavi, S.M.J.; Saeb, S.; Shokrpour, N.

    2017-01-01

    Background: Over the past several years, the rapidly increasing use of mobile phones has raised global concerns about the biological effects of exposure to radiofrequency (RF) radiation. Numerous studies have shown that exposure to electromagnetic fields (EMFs) can be associated with effects on the nervous, endocrine, immune, cardiovascular, hematopoietic and ocular systems. In spite of genetic diversity, the onset and progression of cancer can be controlled by epigenetic mechanisms such as gene promoter methylation. There are extensive studies on the epigenetic changes of the tumor suppressor genes as well as the identification of methylation biomarkers in colorectal cancer. Some studies have revealed that genetic changes can be induced by exposure to RF radiation. However, whether or not RF radiation is capable of inducing epigenetic alteration has not been clarified yet. To date, no study has been conducted on the effect of radiation on epigenetic alterations in colorectal cancer (CRC). Several studies have also shown that methylation of estrogen receptor α (ERα), MYOD, MGMT, SFRP2 and P16 play an important role in CRC. It can be hypothesized that RF exposure can be a reason for the high incidence of CRC in Iran. This study aimed to investigate whether epigenetic pattern of ERα is susceptible to RF radiation and if RF radiation can induce radioadaptive response as epigenetic changes after receiving the challenge dose (γ-ray). Material and Method: 40 male Sprague-Dawley rats were divided into 4 equal groups (Group I: exposure to RF radiation of a GSM cell phone for 4 hours and sacrificed after 24 hours; Group II: RF exposure for 4 hours, exposure to Co-60 gamma radiation (3 Gy) after 24 hours and sacrificed after 72 hrs; Group III: only 3Gy gamma radiation; Group 4: control group). DNA from colon tissues was extracted to evaluate the methylation status by methylation specific PCR. Results: Our finding showed that exposure to GSM cell phone RF radiation was

  8. Effect of Exposure to 900 MHz GSM Mobile Phone Radiofrequency Radiation on Estrogen Receptor Methylation Status in Colon Cells of Male Sprague Dawley Rats

    Directory of Open Access Journals (Sweden)

    Mokarram P.

    2017-03-01

    Full Text Available Background: Over the past several years, the rapidly increasing use of mobile phones has raised global concerns about the biological effects of exposure to radiofrequency (RF radiation. Numerous studies have shown that exposure to electromagnetic fields (EMFs can be associated with effects on the nervous, endocrine, immune, cardiovascular, hematopoietic and ocular systems. In spite of genetic diversity, the onset and progression of cancer can be controlled by epigenetic mechanisms such as gene promoter methylation. There are extensive studies on the epigenetic changes of the tumor suppressor genes as well as the identification of methylation biomarkers in colorectal cancer. Some studies have revealed that genetic changes can be induced by exposure to RF radiation. However, whether or not RF radiation is capable of inducing epigenetic alteration has not been clarified yet. To date, no study has been conducted on the effect of radiation on epigenetic alterations in colorectal cancer (CRC. Several studies have also shown that methylation of estrogen receptor α (ERα, MYOD, MGMT, SFRP2 and P16 play an important role in CRC. It can be hypothesized that RF exposure can be a reason for the high incidence of CRC in Iran. This study aimed to investigate whether epigenetic pattern of ERα is susceptible to RF radiation and if RF radiation can induce radioadaptive response as epigenetic changes after receiving the challenge dose (γ-ray. Material and Method: 40 male Sprague-Dawley rats were divided into 4 equal groups (Group I: exposure to RF radiation of a GSM cell phone for 4 hours and sacrificed after 24 hours; Group II: RF exposure for 4 hours, exposure to Co-60 gamma radiation (3 Gy after 24 hours and sacrificed after 72 hrs; Group III: only 3Gy gamma radiation; Group 4: control group. DNA from colon tissues was extracted to evaluate the methylation status by methylation specific PCR. Results: Our finding showed that exposure to GSM cell phone RF

  9. Geometric radiation exchange factors for axial radiative transfer in an LWR core filled with absorbing-emitting gases

    International Nuclear Information System (INIS)

    Chan, S.H.; Cho, D.H.

    1984-01-01

    A reactor core filled with an emitting-absorbing mixture (like steam, hydrogen gas and fission gases) is considered. Analysis is provided to evaluate axial radiative heat exchange of a rod bundle with a nonuniform axial temperature distribution. The necessary radiation exchange shape factors (geometric mean absorptance, emittance and transmittance) between segments of the complex rod bundle arrangement are presented. They are applicable to arbitrary sizes of segments, well suited for numerical computations

  10. Radiofrequency radiation-induced calcium-ion-efflux enhancement from human and other neuroblastoma cells in culture: [Final technical report

    International Nuclear Information System (INIS)

    Dutta, S.K.; Ghosh, B.; Blackman, C.F.

    1988-01-01

    In order to test the generality of radiofrequency-radiation-induced change in alternation of 45 Ca/sup 2/plus// efflux from avian and feline brain tissues, human neuroblastoma cells were exposed to electromagnetic radiation at 147 MHz, amplitude modulated (AM) at 16 Hz, at specific absorption rates (SAR) of 0.1, 0.05, 0.01, 0.005, 0.001, and 0.0005 Wkg. Significant 45 Ca/sup 2/plus// efflux was obtained at SAR values of 0.05 and 0.005 Wkg. Enchanced efflux at 0.05 Wkg peaked at the 13-to-16 Hz and at the 57.5-to-60 Hz modulation ranges. A Chinese hamster-mouse hybrid neuroblastoma was also shown to exhibit enchanced radiation-induced 45 Ca/sup 2/plus// efflux at an SAR of 0.05 Wkg, using 147 MHz, AM at 16 hz. These results confirm that amplitude-modulated radiofrequency radiation can induce response in cells of nervous tissue origin from widely different animal species including humans. The results are also consistent with reports of similar findings in avian and feline brain tissue reported by others and indicate the general nature of the phenomenon. 9 refs., 3 tabs

  11. Possible cause for altered spatial cognition of prepubescent rats exposed to chronic radiofrequency electromagnetic radiation.

    Science.gov (United States)

    Narayanan, Sareesh Naduvil; Kumar, Raju Suresh; Karun, Kalesh M; Nayak, Satheesha B; Bhat, P Gopalakrishna

    2015-10-01

    The effects of chronic and repeated radiofrequency electromagnetic radiation (RFEMR) exposure on spatial cognition and hippocampal architecture were investigated in prepubescent rats. Four weeks old male Wistar rats were exposed to RF-EMR (900 MHz; SAR-1.15 W/kg with peak power density of 146.60 μW/cm(2)) for 1 h/day, for 28 days. Followed by this, spatial cognition was evaluated by Morris water maze test. To evaluate the hippocampal morphology; H&E staining, cresyl violet staining, and Golgi-Cox staining were performed on hippocampal sections. CA3 pyramidal neuron morphology and surviving neuron count (in CA3 region) were studied using H&E and cresyl violet stained sections. Dendritic arborization pattern of CA3 pyramidal neuron was investigated by concentric circle method. Progressive learning abilities were found to be decreased in RF-EMR exposed rats. Memory retention test performed 24 h after the last training revealed minor spatial memory deficit in RF-EMR exposed group. However, RF-EMR exposed rats exhibited poor spatial memory retention when tested 48 h after the final trial. Hirano bodies and Granulovacuolar bodies were absent in the CA3 pyramidal neurons of different groups studied. Nevertheless, RF-EMR exposure affected the viable cell count in dorsal hippocampal CA3 region. RF-EMR exposure influenced dendritic arborization pattern of both apical and basal dendritic trees in RF-EMR exposed rats. Structural changes found in the hippocampus of RF-EMR exposed rats could be one of the possible reasons for altered cognition.

  12. Optical radiation emitted by a silver surface bombarded by low-energy electrons

    International Nuclear Information System (INIS)

    Miserey, F.; Lebon, P.; Septier, A.; Trehin, F.; Beaugrand, C.

    1975-01-01

    Thick silver targets are obtained on flat glass discs by evaporation in a UHV cell (p -10 torr) and their optical coefficients measured by ellipsometry. A field-emission electron gun bombards a limited region of the target, corresponding to the entry pupil of a light spectrometer. Radiation emitted in the domain 250-600nm is analyzed for both normal and parallel polarizations. Spectral distributions of photons are obtained by using a very sensitive counting device including a multi channel analyzer. First experimental results concerning optical radiation generated by 6keV electrons are reported and compared to Transition Radiation and Bremsstrahlung theoretical spectra [fr

  13. Impact of radiofrequency radiation on DNA damage and antioxidants in peripheral blood lymphocytes of humans residing in the vicinity of mobile phone base stations.

    Science.gov (United States)

    Zothansiama; Zosangzuali, Mary; Lalramdinpuii, Miriam; Jagetia, Ganesh Chandra

    2017-01-01

    Radiofrequency radiations (RFRs) emitted by mobile phone base stations have raised concerns on its adverse impact on humans residing in the vicinity of mobile phone base stations. Therefore, the present study was envisaged to evaluate the effect of RFR on the DNA damage and antioxidant status in cultured human peripheral blood lymphocytes (HPBLs) of individuals residing in the vicinity of mobile phone base stations and comparing it with healthy controls. The study groups matched for various demographic data including age, gender, dietary pattern, smoking habit, alcohol consumption, duration of mobile phone use and average daily mobile phone use. The RF power density of the exposed individuals was significantly higher (p base stations, showed significantly (p base station/s. The analysis of various antioxidants in the plasma of exposed individuals revealed a significant attrition in glutathione (GSH) concentration (p < 0.01), activities of catalase (CAT) (p < 0.001) and superoxide dismutase (SOD) (p < 0.001) and rise in lipid peroxidation (LOO) when compared to controls. Multiple linear regression analyses revealed a significant association among reduced GSH concentration (p < 0.05), CAT (p < 0.001) and SOD (p < 0.001) activities and elevated MN frequency (p < 0.001) and LOO (p < 0.001) with increasing RF power density.

  14. Neutron emission from 9Be nucleus under the action of β+ and γ radiation emitted in radioactive decay

    International Nuclear Information System (INIS)

    Vo Dak Bang; Gangrskij, Yu.P.; Miller, M.B.; Mikhajlov, L.V.; Fam Zui Khien; Kharisov, I.F.

    1980-01-01

    The neutron yield from the 9 Be nucleus under the action of beta and gamma-radiation emitted at the radiative decay of 11 C, 62 Cu, 66 Ga, 74 Br isotopes is measured. These isotopes differ essentially by the emitted radiation spectra. The contribution of various processes ((γ, n)-reactions, inelastic scattering and positron nonradiative annihilation) to the neutron yield observed is determined [ru

  15. Correlation of electromagnetic radiation emitted from coal or rock to supporting resistance

    Energy Technology Data Exchange (ETDEWEB)

    Jia, Hui-lin; Wang, En-yuan; Song, Xiao-yan; Zhang, Hong-jie; Li, Zhong-hui [China University of Mining & Technology, Xuzhou (China). School of Safety Engineering

    2009-05-15

    More accurate forecasting of rock burst might be possible from observations of electromagnetic radiation emitted in the mine. We analyzed experimental observations and field data from the Muchengjian coal mine to study the relationship between electromagnetic radiation signal intensity and stress during the fracturing of coal, or rock, and samples under load. The results show that the signal intensity is positively correlated with stress. In addition, we investigated the change in the electromagnetic radiation intensity, the supporting resistance in a real coal mine environment, and the coal or rock stress in the mining area. The data analysis indicates that: (1) electromagnetic radiation intensity can accurately reflect the distribution of stress in the mining area; and, (2) there is a correlation between electromagnetic radiation intensity and supporting resistance. The research has some practical guiding significance for rock burst forecasting and for the prevention of accidents in coal mines. 9 refs., 6 figs.

  16. Biological effects of exposure to non-ionising electromagnetic fields and radiation: III radiofrequency and microwave radiation

    International Nuclear Information System (INIS)

    Saunders, R.D.; Kowalczuk, C.I.; Sienkiewicz, Z.J.

    1991-12-01

    The biological effects of experimental exposure to radiofrequency (RF) and microwave radiation above 100 kHz are reviewed with the intention of providing a summary of effects directly relevant to considerations of the health and safety of exposed people. The biological bases for restricting exposures are also briefly discussed. Studies of the possible effects of electromagnetic field exposure on human populations are described in a separate report. The majority of the biological effects of acute exposure to radiofrequency (RF) and microwave radiation are consistent with responses to induced heating, resulting either from frank rises in tissue or body temperature of about 1 0 C or more, or from responses involved in minimising the total heat load. Most responses have been reported at specific energy absorption rates (SARs) above about 1-2 W kg -1 in different animal species exposed under various environmental conditions. These animal, particularly primate, data indicate the sorts of responses that are likely to occur in humans subject to a sufficient heat load. In addition, most animal and cell culture data indicate that RF and microwave exposure is not mutagenic and so will not result in somatic mutation or in hereditary effects; such exposure is therefore unlikely to initiate cancers. With some exceptions that are described below, restrictions on the acute exposure of humans to RF or microwave radiation should be based on the acute responses to raised body temperature. It seems probable that healthy people can tolerate short-term (minute-hour) rises in body temperature of up to about 1 0 C. This rise is well below the maximum tolerable increase but nevertheless represents a significant thermal load. The evidence suggests that the exposure of resting humans in moderate environments at whole-body SARs of 1 W kg -1 , and up to 4 W kg -1 for short periods, will result in body temperature rises of less than 1 0 C. A restriction of whole-body SAR for healthy people to 0

  17. “Triple M” Effect: A Proposed Mechanism to Explain Increased Dental Amalgam Microleakage after Exposure to Radiofrequency Electromagnetic Radiation

    Science.gov (United States)

    Mortazavi, Gh.; Mortazavi, S.A.R.; Mehdizadeh, A.R.

    2018-01-01

    A large body of evidence now indicates that the amount of mercury released from dental amalgam fillings can be significantly accelerated by exposure to radiofrequency electromagnetic fields (RF-EMFs) such as common mobile phones and magnetic resonance imaging (MRI). Studies performed on the increased microleakage of dental amalgam restorations after exposure to RF-EMFs have further supported these findings. Although the accelerated microleakage induced by RF-EMFs is clinically significant, the entire mechanisms of this phenomenon are not clearly understood. In this paper, we introduce “Triple M” effect, a new evidence-based theory which can explain the accelerated microleakage of dental amalgam fillings after exposure to different sources of electromagnetic radiation. Based on this theory, there are saliva-filled tiny spaces between amalgam and the tooth. Exposure of the oral cavity to RF-EMFs increases the energy of these small amounts of saliva. Due to the small mass of saliva in these tiny spaces, a small amount of energy will be required for heating. Moreover, reflection of the radiofrequency radiation on the inner walls of the tiny spaces causes interference which in turn produces some “hot spots” in these spaces. Finally, formation of gas bubbles in response to increased temperature and very rapid expansion of these bubbles will accelerate the microleakage of amalgam. Experiments that confirm the validity of this theory are discussed. PMID:29732349

  18. "Triple M" Effect: A Proposed Mechanism to Explain Increased Dental Amalgam Microleakage after Exposure to Radiofrequency Electromagnetic Radiation.

    Science.gov (United States)

    Mortazavi, Gh; Mortazavi, S A R; Mehdizadeh, A R

    2018-03-01

    A large body of evidence now indicates that the amount of mercury released from dental amalgam fillings can be significantly accelerated by exposure to radiofrequency electromagnetic fields (RF-EMFs) such as common mobile phones and magnetic resonance imaging (MRI). Studies performed on the increased microleakage of dental amalgam restorations after exposure to RF-EMFs have further supported these findings. Although the accelerated microleakage induced by RF-EMFs is clinically significant, the entire mechanisms of this phenomenon are not clearly understood. In this paper, we introduce "Triple M" effect, a new evidence-based theory which can explain the accelerated microleakage of dental amalgam fillings after exposure to different sources of electromagnetic radiation. Based on this theory, there are saliva-filled tiny spaces between amalgam and the tooth. Exposure of the oral cavity to RF-EMFs increases the energy of these small amounts of saliva. Due to the small mass of saliva in these tiny spaces, a small amount of energy will be required for heating. Moreover, reflection of the radiofrequency radiation on the inner walls of the tiny spaces causes interference which in turn produces some "hot spots" in these spaces. Finally, formation of gas bubbles in response to increased temperature and very rapid expansion of these bubbles will accelerate the microleakage of amalgam. Experiments that confirm the validity of this theory are discussed.

  19. Preliminary Assessment of Radiofrequency Radiation Exposure Level, From Mobile Base Stations in Ajaokuta and Environs, Kogi State, Nigeria

    International Nuclear Information System (INIS)

    Ushie, P. O.; Nwankwo, U.J.V.; Osahun, O. D.; Ayinmode, B.

    2013-01-01

    We present the result of a preliminary assessment of radio-frequency radiation exposure from selected mobile base stations in Ajaokuta environs using radio frequency (RF) meter (electromoge meter). The Power density of RF radiation within a radial distance of 125m was measured. Although values fluctuated due to the influence of unavoidable factors suspected to be interferences from other electromagnetic sources around reference base stations, we show from analysis that radiation exposure level is far below the standard limit (10W/cm 2 or 10 7 μW/m 2 ) set by the International Commission on Non-ionizing Radiation Protection (ICNIRP) regulatory agencies. The assessment was done in about ten (10) base stations in Ajaokuta, Kogi state. The position and elevation of the base stations were noted using a global positioning system (GPS) to ascertain the position of such stations on the world map. It was discovered that the limit of exposure to radio frequency radiation set by International Commission on Non-ionizing, Radiation Protection (ICNIRP) of 900MHz band expressed in the same unit as 10W/cm 2 or 10 7 μW/m 2 was not exceeded, the values were also influenced by some inevitable factors. Positions of most of the stations are sited close to homes.

  20. Radiofrequency radiation from nearby base stations gives high levels in an apartment in Stockholm, Sweden: A case report

    Science.gov (United States)

    Hardell, Lennart; Carlberg, Michael; Hedendahl, Lena K.

    2018-01-01

    Exposure to radiofrequency (RF) radiation was classified in 2011 as a possible human carcinogen, Group 2B, by the International Agency for Research on Cancer of the World Health Organisation. Evidence of the risk of cancer risk has since strengthened. Exposure is changing due to the rapid development of technology resulting in increased ambient radiation. RF radiation of sufficient intensity heats tissues, but the energy is insufficient to cause ionization, hence it is called non-ionizing radiation. These non-thermal exposure levels have resulted in biological effects in humans, animals and cells, including an increased cancer risk. In the present study, the levels of RF radiation were measured in an apartment close to two groups of mobile phone base stations on the roof. A total of 74,531 measurements were made corresponding to ~83 h of recording. The total mean RF radiation level was 3,811 µW/m2 (range 15.2–112,318 µW/m2) for the measurement of the whole apartment, including balconies. Particularly high levels were measured on three balconies and 3 of 4 bedrooms. The total mean RF radiation level decreased by 98% when the measured down-links from the base stations for 2, 3 and 4 G were disregarded. The results are discussed in relation to the detrimental health effects of non-thermal RF radiation. Due to the current high RF radiation, the apartment is not suitable for long-term living, particularly for children who may be more sensitive than adults. For a definitive conclusion regarding the effect of RF radiation from nearby base stations, one option would be to turn them off and repeat the measurements. However, the simplest and safest solution would be to turn them off and dismantle them. PMID:29725476

  1. Radiofrequency radiation from nearby base stations gives high levels in an apartment in Stockholm, Sweden: A case report.

    Science.gov (United States)

    Hardell, Lennart; Carlberg, Michael; Hedendahl, Lena K

    2018-05-01

    Exposure to radiofrequency (RF) radiation was classified in 2011 as a possible human carcinogen, Group 2B, by the International Agency for Research on Cancer of the World Health Organisation. Evidence of the risk of cancer risk has since strengthened. Exposure is changing due to the rapid development of technology resulting in increased ambient radiation. RF radiation of sufficient intensity heats tissues, but the energy is insufficient to cause ionization, hence it is called non-ionizing radiation. These non-thermal exposure levels have resulted in biological effects in humans, animals and cells, including an increased cancer risk. In the present study, the levels of RF radiation were measured in an apartment close to two groups of mobile phone base stations on the roof. A total of 74,531 measurements were made corresponding to ~83 h of recording. The total mean RF radiation level was 3,811 µW/m 2 (range 15.2-112,318 µW/m 2 ) for the measurement of the whole apartment, including balconies. Particularly high levels were measured on three balconies and 3 of 4 bedrooms. The total mean RF radiation level decreased by 98% when the measured down-links from the base stations for 2, 3 and 4 G were disregarded. The results are discussed in relation to the detrimental health effects of non-thermal RF radiation. Due to the current high RF radiation, the apartment is not suitable for long-term living, particularly for children who may be more sensitive than adults. For a definitive conclusion regarding the effect of RF radiation from nearby base stations, one option would be to turn them off and repeat the measurements. However, the simplest and safest solution would be to turn them off and dismantle them.

  2. Temperature mapping and thermal dose calculation in combined radiation therapy and 13.56 MHz radiofrequency hyperthermia for tumor treatment

    Science.gov (United States)

    Kim, Jung Kyung; Prasad, Bibin; Kim, Suzy

    2017-02-01

    To evaluate the synergistic effect of radiotherapy and radiofrequency hyperthermia therapy in the treatment of lung and liver cancers, we studied the mechanism of heat absorption and transfer in the tumor using electro-thermal simulation and high-resolution temperature mapping techniques. A realistic tumor-induced mouse anatomy, which was reconstructed and segmented from computed tomography images, was used to determine the thermal distribution in tumors during radiofrequency (RF) heating at 13.56 MHz. An RF electrode was used as a heat source, and computations were performed with the aid of the multiphysics simulation platform Sim4Life. Experiments were carried out on a tumor-mimicking agar phantom and a mouse tumor model to obtain a spatiotemporal temperature map and thermal dose distribution. A high temperature increase was achieved in the tumor from both the computation and measurement, which elucidated that there was selective high-energy absorption in tumor tissue compared to the normal surrounding tissues. The study allows for effective treatment planning for combined radiation and hyperthermia therapy based on the high-resolution temperature mapping and high-precision thermal dose calculation.

  3. Adaptive response in human blood lymphocytes exposed to non-ionizing radiofrequency fields: resistance to ionizing radiation-induced damage.

    Science.gov (United States)

    Sannino, Anna; Zeni, Olga; Romeo, Stefania; Massa, Rita; Gialanella, Giancarlo; Grossi, Gianfranco; Manti, Lorenzo; Vijayalaxmi; Scarfì, Maria Rosaria

    2014-03-01

    The aim of this preliminary investigation was to assess whether human peripheral blood lymphocytes which have been pre-exposed to non-ionizing radiofrequency fields exhibit an adaptive response (AR) by resisting the induction of genetic damage from subsequent exposure to ionizing radiation. Peripheral blood lymphocytes from four healthy donors were stimulated with phytohemagglutinin for 24 h and then exposed for 20 h to 1950 MHz radiofrequency fields (RF, adaptive dose, AD) at an average specific absorption rate of 0.3 W/kg. At 48 h, the cells were subjected to a challenge dose (CD) of 1.0 or 1.5 Gy X-irradiation (XR, challenge dose, CD). After a 72 h total culture period, cells were collected to examine the incidence of micronuclei (MN). There was a significant decrease in the number of MN in lymphocytes exposed to RF + XR (AD + CD) as compared with those subjected to XR alone (CD). These observations thus suggested a RF-induced AR and induction of resistance to subsequent damage from XR. There was variability between the donors in RF-induced AR. The data reported in our earlier investigations also indicated a similar induction of AR in human blood lymphocytes that had been pre-exposed to RF (AD) and subsequently treated with a chemical mutagen, mitomycin C (CD). Since XR and mitomycin-C induce different kinds of lesions in cellular DNA, further studies are required to understand the mechanism(s) involved in the RF-induced adaptive response.

  4. Effects of radiation emitted from visual display terminals on the oral health status

    International Nuclear Information System (INIS)

    Kazem, H.H.

    2008-01-01

    This study was designed to investigate the effects of exposure to radiation emitted from visual display terminals (VDTs) on the oral health status; a cross sectional study was carried out on 100 participants both males and females with age ranging between 22- 40 years working in various places in Cairo. They were divided into two groups; the first consists of 50 subjects working in front of VDTs eight hours min. daily, min. 5 days/ week, 2 years or more, and the other group 50 subjects working away from any VDTs. Both groups were subjected to both oral and dental examinations, including soft tissues assessment by using gingival index (GI) and hard tissues assessment by using decayed, missed, filled (DMF) index. Saliva analysis was done including ph analysis by ph meter cyberscan 500 and trace elements analysis by ion chromatography and salivary immunoglobulin A (sIgA) analysis by ELISA, body temperature by using digital thermometer. The values were compared between both groups and also between before and after exposure in the exposed group. The results demonstrated that the difference in the mean values of either GI or DMF or ph or anions and cations or sIgA levels between exposed and non exposed groups or even between before and after exposure in the exposed group was found to be statistically insignificant. On the other hand there were significant changes in the mean values of body temperature between exposed and non-exposed group and also between before and after exposure in the exposed group. Accordingly, within the limits of this study we can conclude that radiation emitted from VDTs affects body temperature, but do not have any effect on oral health including; hard or soft tissues or salivary components. This might be explained by the radiation with very low energy emitted from VDTs

  5. Effects of radiation emitted from visual display terminals on the oral health status

    Energy Technology Data Exchange (ETDEWEB)

    Kazem, H H [National Center for Radiation Research and Technology, Atomic Energy Authority, Cairo (Egypt)

    2008-07-01

    This study was designed to investigate the effects of exposure to radiation emitted from visual display terminals (VDTs) on the oral health status; a cross sectional study was carried out on 100 participants both males and females with age ranging between 22- 40 years working in various places in Cairo. They were divided into two groups; the first consists of 50 subjects working in front of VDTs eight hours min. daily, min. 5 days/ week, 2 years or more, and the other group 50 subjects working away from any VDTs. Both groups were subjected to both oral and dental examinations, including soft tissues assessment by using gingival index (GI) and hard tissues assessment by using decayed, missed, filled (DMF) index. Saliva analysis was done including ph analysis by ph meter cyberscan 500 and trace elements analysis by ion chromatography and salivary immunoglobulin A (sIgA) analysis by ELISA, body temperature by using digital thermometer. The values were compared between both groups and also between before and after exposure in the exposed group. The results demonstrated that the difference in the mean values of either GI or DMF or ph or anions and cations or sIgA levels between exposed and non exposed groups or even between before and after exposure in the exposed group was found to be statistically insignificant. On the other hand there were significant changes in the mean values of body temperature between exposed and non-exposed group and also between before and after exposure in the exposed group. Accordingly, within the limits of this study we can conclude that radiation emitted from VDTs affects body temperature, but do not have any effect on oral health including; hard or soft tissues or salivary components. This might be explained by the radiation with very low energy emitted from VDTs.

  6. Soil moisture estimation using reflected solar and emitted thermal infrared radiation

    Science.gov (United States)

    Jackson, R. D.; Cihlar, J.; Estes, J. E.; Heilman, J. L.; Kahle, A.; Kanemasu, E. T.; Millard, J.; Price, J. C.; Wiegand, C. L.

    1978-01-01

    Classical methods of measuring soil moisture such as gravimetric sampling and the use of neutron moisture probes are useful for cases where a point measurement is sufficient to approximate the water content of a small surrounding area. However, there is an increasing need for rapid and repetitive estimations of soil moisture over large areas. Remote sensing techniques potentially have the capability of meeting this need. The use of reflected-solar and emitted thermal-infrared radiation, measured remotely, to estimate soil moisture is examined.

  7. Assessment of Radiofrequency Radiation Distribution around Mobile Base Stations in Makurdi, Benue State

    OpenAIRE

    J.T. Iortile; E.H. Agba

    2014-01-01

    The radiofrequency field levels of selected MTN and ZAIN base stations in Makurdi were measured using electromagnetic field tester (EMF 827, Lutron). Measurements were done at distances of approximately 5.00, 10.00, 15.00 and 20.00 metres for each base station at the North, South, West, and East directions. Results shows that the average magnetic field levels of MTN and ZAIN base station ranged between 0.09 μT to 0.15 μT. The mean electric field values for eye, brain and muscles ranged betwee...

  8. Fabrication and characterization of UV-emitting nanoparticles as novel radiation sensitizers targeting hypoxic tumor cells

    Science.gov (United States)

    Squillante, Michael R.; Jüstel, Thomas; Anderson, R. Rox; Brecher, Charles; Chartier, Daniel; Christian, James F.; Cicchetti, Nicholas; Espinoza, Sara; McAdams, Daniel R.; Müller, Matthias; Tornifoglio, Brooke; Wang, Yimin; Purschke, Martin

    2018-06-01

    Radiation therapy is one of the primary therapeutic techniques for treating cancer, administered to nearly two-thirds of all cancer patients. Although largely effective in killing cancer cells, radiation therapy, like other forms of cancer treatment, has difficulty dealing with hypoxic regions within solid tumors. The incomplete killing of cancer cells can lead to recurrence and relapse. The research presented here is investigating the enhancement of the efficacy of radiation therapy by using scintillating nanoparticles that emit UV photons. UV photons, with wavelengths between 230 nm and 280 nm, are able to inactivate cells due to their direct interaction with DNA, causing a variety of forms of damage. UV-emitting nanoparticles will enhance the treatment in two ways: first by generating UV photons in the immediate vicinity of cancer cells, leading to direct and oxygen-independent DNA damage, and second by down-converting the applied higher energy X-rays into softer X-rays and particles that are more efficiently absorbed in the targeted tumor region. The end result will be nanoparticles with a higher efficacy in the treatment of hypoxic cells in the tumor, filling an important, unmet clinical need. Our preliminary experiments show an increase in cell death using scintillating LuPO4:Pr nanoparticles over that achieved by the primary radiation alone. This work describes the fabrication of the nanoparticles, their physical characterization, and the spectroscopic characterization of the UV emission. The work also presents in vitro results that demonstrate an enhanced efficacy of cell killing with x-rays and a low unspecific toxicity of the nanoparticles.

  9. Radiofrequency radiation at Stockholm Central Railway Station in Sweden and some medical aspects on public exposure to RF fields.

    Science.gov (United States)

    Hardell, Lennart; Koppel, Tarmo; Carlberg, Michael; Ahonen, Mikko; Hedendahl, Lena

    2016-10-01

    The Stockholm Central Railway Station in Sweden was investigated for public radiofrequency (RF) radiation exposure. The exposimeter EME Spy 200 was used to collect the RF exposure data across the railway station. The exposimeter covers 20 different radiofrequency bands from 88 to 5,850 MHz. In total 1,669 data points were recorded. The median value for total exposure was 921 µW/m2 (or 0.092 µW/cm2; 1 µW/m2=0.0001 µW/cm2) with some outliers over 95,544 µW/m2 (6 V/m, upper detection limit). The mean total RF radiation level varied between 2,817 to 4,891 µW/m2 for each walking round. High mean measurements were obtained for GSM + UMTS 900 downlink varying between 1,165 and 2,075 µW/m2. High levels were also obtained for UMTS 2100 downlink; 442 to 1,632 µW/m2. Also LTE 800 downlink, GSM 1800 downlink, and LTE 2600 downlink were in the higher range of measurements. Hot spots were identified, for example close to a wall mounted base station yielding over 95,544 µW/m2 and thus exceeding the exposimeter's detection limit. Almost all of the total measured levels were above the precautionary target level of 3-6 µW/m2 as proposed by the BioInitiative Working Group in 2012. That target level was one-tenth of the scientific benchmark providing a safety margin either for children, or chronic exposure conditions. We compare the levels of RF radiation exposures identified in the present study to published scientific results reporting adverse biological effects and health harm at levels equivalent to, or below those measured in this Stockholm Central Railway Station project. It should be noted that these RF radiation levels give transient exposure, since people are generally passing through the areas tested, except for subsets of people who are there for hours each day of work.

  10. Radiofrequency electromagnetic fields emitted from base stations of DECT cordless phones and the risk of glioma and meningioma (Interphone Study Group, Germany)

    DEFF Research Database (Denmark)

    Schüz, Joachim; Böhler, Eva; Schlehofer, Brigitte

    2006-01-01

    The objective of this study was to test the hypothesis that exposure to continuous low-level radiofrequency electromagnetic fields (RF EMFs) increases the risk of glioma and meningioma. Participants in a population-based case-control study in Germany on the risk of brain tumors in relation...... to cellular phone use were 747 incident brain tumor cases between the ages of 30 and 69 years and 1494 matched controls. The exposure measure of this analysis was the location of a base station of a DECT (Digital Enhanced Cordless Telecommunications) cordless phone close to the bed, which was used as a proxy...

  11. Electromagnetic noise inhibits radiofrequency radiation-induced DNA damage and reactive oxygen species increase in human lens epithelial cells

    Science.gov (United States)

    Wu, Wei; Wang, KaiJun; Ni, Shuang; Ye, PanPan; Yu, YiBo; Ye, Juan; Sun, LiXia

    2008-01-01

    Purpose The goal of this study was to investigate whether superposing of electromagnetic noise could block or attenuate DNA damage and intracellular reactive oxygen species (ROS) increase of cultured human lens epithelial cells (HLECs) induced by acute exposure to 1.8 GHz radiofrequency field (RF) of the Global System for Mobile Communications (GSM). Methods An sXc-1800 RF exposure system was used to produce a GSM signal at 1.8 GHz (217 Hz amplitude-modulated) with the specific absorption rate (SAR) of 1, 2, 3, and 4 W/kg. After 2 h of intermittent exposure, the ROS level was assessed by the fluorescent probe, 2',7'-dichlorodihydrofluorescein diacetate (DCFH-DA). DNA damage to HLECs was examined by alkaline comet assay and the phosphorylated form of histone variant H2AX (γH2AX) foci formation assay. Results After exposure to 1.8 GHz RF for 2 h, HLECs exhibited significant intracellular ROS increase in the 2, 3, and 4 W/kg groups. RF radiation at the SAR of 3 W/kg and 4 W/kg could induce significant DNA damage, examined by alkaline comet assay, which was used to detect mainly single strand breaks (SSBs), while no statistical difference in double strand breaks (DSBs), evaluated by γH2AX foci, was found between RF exposure (SAR: 3 and 4 W/kg) and sham exposure groups. When RF was superposed with 2 μT electromagnetic noise could block RF-induced ROS increase and DNA damage. Conclusions DNA damage induced by 1.8 GHz radiofrequency field for 2 h, which was mainly SSBs, may be associated with the increased ROS production. Electromagnetic noise could block RF-induced ROS formation and DNA damage. PMID:18509546

  12. Sources of exposure to radiofrequency and microwave radiations in the UK

    CERN Document Server

    Allen, S G

    1983-01-01

    A comprehensive survey is presented of sources of radiofrequency and microwave fields in the United Kingdom that give rise to the exposure of both workers and the general public. The information is presented in the context of the existing guidelines for the restrictions of exposures to such fields and of proposed new guidelines based on restricting the rate of energy absorption averaged over the human body to 0.4 watts per kilogram or, at frequencies below 3 MHz, limiting field strengths to 600 volts per metre. It is concluded that unless account is taken of time averaging relaxations and possible modifying factors relating to energy absorption arising under near field and partial body exposure conditions, there may be difficulties in applying the proposed guidelines to the use of radio frequencies for industrial heating purposes and to some portable and mobile transmitters used for communications.

  13. High radiofrequency radiation at Stockholm Old Town: An exposimeter study including the Royal Castle, Supreme Court, three major squares and the Swedish Parliament

    OpenAIRE

    Hardell, Lennart; Carlberg, Michael; Koppel, Tarmo; Hedendahl, Lena

    2017-01-01

    Exposure to radiofrequency (RF) radiation was classified as a possible human carcinogen, Group 2B, by the International Agency for Research on Cancer at WHO in 2011. The exposure pattern is changing due to the rapid development of technology. Outdoor RF radiation level was measured during five tours in Stockholm Old Town in April, 2016 using the EME Spy 200 exposimeter with 20 predefined frequencies. The results were based on 10,437 samples in total. The mean level of the total RF radiation w...

  14. Measurement and Analysis of Radio-frequency Radiation Exposure Level from Different Mobile Base Transceiver Stations in Ajaokuta and Environs, Nigeria

    OpenAIRE

    Ushie, P. O.; Nwankwo, Victor U. J.; Bolaji, Ayinmode; Osahun, O. D.

    2013-01-01

    We present the result of a preliminary assessment of radio-frequency radiation exposure from selected mobile base stations in Ajaokuta environs. The Power density of RF radiation within a radial distance of 125m was measured. Although values fluctuated due to the influence of other factors, including wave interference from other electromagnetic sources around reference base stations, we show from analysis that radiation exposure level is below the standard limit (4.5W/sqm for 900MHz and 9W/sq...

  15. Volatiles emitted from flowers by gamma-radiated and nonradiated Jasminum polyanthum Franch. in situ

    International Nuclear Information System (INIS)

    Christensen, L.P.; Jakobsen, H.B.; Kristiansen, K.; Moller, J.

    1997-01-01

    Volatile compounds emitted from flowers of Jasminum polyanthum Pepita in situ were collected by dynamic headspace technique and analyzed by GC-FID and GC-MS. A total of 32 compounds were identified. The flower scent was dominated by benzyl acetate (57.8%), p-cresol (12.2%), (E)-isoeugenol (9.7%), eugenol (3.5%), 2-methoxy-p-cresol (3.1%), linalool (3.0%), phenethyl acetate (2.1%), and (Z)3-hexenyl butyrate (1.9%). The strong scent of Pepita reduces its production potentialities as a pot plant, thus the possibility to reduce or modify the emission of volatiles from Pepita by mutagenesis was investigated. The average total yields of volatiles in Pepita were approximately 2800 ng flower-1 h-1, and in one gamma-radiated clone a significantly lower yield of 1050 ng flower-1 h-1 was found. The volatile profiles of the gamma-radiated plants were made up of the same 32 compounds found in Pepita. Significant differences in the headspace composition between Pepita and gamma-radiated plants were found for some of the major volatiles

  16. Relative risk analysis in regulating the use of radiation-emitting medical devices. A preliminary application

    Energy Technology Data Exchange (ETDEWEB)

    Jones, E.D.; Banks, W.W.; Altenbach, T.J.; Fischer, L.E. [Lawrence Livermore National Lab., CA (United States)

    1995-09-01

    This report describes a preliminary application of an analysis approach for assessing relative risks in the use of radiation- emitting medical devices. Results are presented on human-initiated actions and failure modes that are most likely to occur in the use of the Gamma Knife, a gamma irradiation therapy device. This effort represents an initial step in a US Nuclear Regulatory Commission (NRC) plan to evaluate the potential role of risk analysis in regulating the use of nuclear medical devices. For this preliminary application of risk assessment, the focus was to develop a basic process using existing techniques for identifying the most likely risk contributors and their relative importance. The approach taken developed relative risk rankings and profiles that incorporated the type and quality of data available and could present results in an easily understood form. This work was performed by the Lawrence Livermore National Laboratory for the NRC.

  17. Relative risk analysis in regulating the use of radiation-emitting medical devices. A preliminary application

    International Nuclear Information System (INIS)

    Jones, E.D.; Banks, W.W.; Altenbach, T.J.; Fischer, L.E.

    1995-09-01

    This report describes a preliminary application of an analysis approach for assessing relative risks in the use of radiation- emitting medical devices. Results are presented on human-initiated actions and failure modes that are most likely to occur in the use of the Gamma Knife, a gamma irradiation therapy device. This effort represents an initial step in a US Nuclear Regulatory Commission (NRC) plan to evaluate the potential role of risk analysis in regulating the use of nuclear medical devices. For this preliminary application of risk assessment, the focus was to develop a basic process using existing techniques for identifying the most likely risk contributors and their relative importance. The approach taken developed relative risk rankings and profiles that incorporated the type and quality of data available and could present results in an easily understood form. This work was performed by the Lawrence Livermore National Laboratory for the NRC

  18. Resonance effects of transition radiation emitted from thin foil stacks using electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Awata, Takaaki; Yajima, Kazuaki; Tanaka, Takashi [Kyoto Univ. (Japan). Faculty of Engineering; and others

    1997-03-01

    Transition Radiation(TR) X rays are expected to be a high brilliant X-ray source because the interference among TR X rays emitted from many thin foils placed periodically in vacuum can increase their intensity and make them quasi-monochromatic. In order to study the interference (resonance) effects of TR, we measured the energy spectra of TR for several sets of thin-foil stacks at various emission angles. It was found that the resonance effects of TR are classified into intrafoil and interfoil resonances and the intensity of TR X rays increases nonlinearly with increasing foil number, attributing to the interfoil resonance. It became evident that the brilliance of TR is as high as that of SR. (author)

  19. Mobile phone base station-emitted radiation does not induce phosphorylation of Hsp27.

    Science.gov (United States)

    Hirose, H; Sakuma, N; Kaji, N; Nakayama, K; Inoue, K; Sekijima, M; Nojima, T; Miyakoshi, J

    2007-02-01

    An in vitro study focusing on the effects of low-level radiofrequency (RF) fields from mobile radio base stations employing the International Mobile Telecommunication 2000 (IMT-2000) cellular system was conducted to test the hypothesis that modulated RF fields act to induce phosphorylation and overexpression of heat shock protein hsp27. First, we evaluated the responses of human cells to microwave exposure at a specific absorption rate (SAR) of 80 mW/kg, which corresponds to the limit of the average whole-body SAR for general public exposure defined as a basic restriction in the International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines. Second, we investigated whether continuous wave (CW) and Wideband Code Division Multiple Access (W-CDMA) modulated signal RF fields at 2.1425 GHz induced activation or gene expression of hsp27 and other heat shock proteins (hsps). Human glioblastoma A172 cells were exposed to W-CDMA radiation at SARs of 80 and 800 mW/kg for 2-48 h, and CW radiation at 80 mW/kg for 24 h. Human IMR-90 fibroblasts from fetal lungs were exposed to W-CDMA at 80 and 800 mW/kg for 2 or 28 h, and CW at 80 mW/kg for 28 h. Under the RF field exposure conditions described above, no significant differences in the expression levels of phosphorylated hsp27 at serine 82 (hsp27[pS82]) were observed between the test groups exposed to W-CDMA or CW signal and the sham-exposed negative controls, as evaluated immediately after the exposure periods by bead-based multiplex assays. Moreover, no noticeable differences in the gene expression of hsps were observed between the test groups and the negative controls by DNA Chip analysis. Our results confirm that exposure to low-level RF field up to 800 mW/kg does not induce phosphorylation of hsp27 or expression of hsp gene family.

  20. Toxicologic study of electromagnetic radiation emitted by television and video display screens and cellular telephones on chickens and mice

    International Nuclear Information System (INIS)

    Bastide, M.; Youbicier-Simo, B.J.; Lebecq, J.C.; Giaimis, J.; Youbicier-Simo, B.J.

    2001-01-01

    The effects of continuous exposure of chick embryos and young chickens to the electromagnetic fields (EMFs) emitted by video display units (VDUs) and GSM cell phone radiation, either the whole spectrum emitted or attenuated by a copper gauze, were investigated. Permanent exposure to the EMFs radiated by a VDU was associated with significantly increased fetal loss (47-68%) and markedly depressed levels of circulating specific antibodies (lgG), corticosterone and melatonin. We have also shown that under chronic exposure conditions, GSM cell phone radiation was harmful to chick embryos, stressful for healthy mice and, in this species, synergistic with cancer insofar as it depleted stress hormones. The same pathological results were observed after substantial reduction of the microwaves radiated from the cell phone by attenuating them with a copper gauze. (author)

  1. Effects of combined radiofrequency radiation exposure on levels of reactive oxygen species in neuronal cells

    International Nuclear Information System (INIS)

    Kang, Kyoung Ah; Lee, Hyung Chul; Lee, Je-Jung

    2014-01-01

    The objective of this study was to investigate the effects of the combined RF radiation (837 MHz CDMA plus 1950 MHz WCDMA) signal on levels of intracellular reactive oxygen species (ROS) in neuronal cells. Exposure of the combined RF signal was conducted at specific absorption rate values of 2 W/kg of CDMA plus 2 W/kg of WCDMA for 2 h. Co-exposure to combined RF radiation with either H 2 O 2 or menadione was also performed. The experimental exposure groups were incubator control, sham-exposed, combined RF radiation-exposed with or without either H 2 O 2 or menadione groups. The intracellular ROS level was measured by flow cytometry using the fluorescent probe dichlorofluorescein diacetate. Intracellular ROS levels were not consistently affected by combined RF radiation exposure alone in a time-dependent manner in U87, PC12 or SH-SY5Y cells. In neuronal cells exposed to combined RF radiation with either H 2 O 2 or menadione, intracellular ROS levels showed no statically significant alteration compared with exposure to menadione or H 2 O 2 alone. These findings indicate that neither combined RF radiation alone nor combined RF radiation with menadione or H 2 O 2 influences the intracellular ROS level in neuronal cells such as U87, PC12 or SH-SY5Y. (author)

  2. On the radiation emitted by a particle falling into a black hole in the semi-relativistic approximation

    International Nuclear Information System (INIS)

    Coretti, C.; Ferrari, V.

    1986-01-01

    In this paper the limits of applicability of the semi-relativistic approximation for estimating the radiation emitted in processes of capture of particles by black holes are discussed. It is shown that it gives reliable estimates in the case of spherically symmetric black holes, but it fails in the case of rotating black holes

  3. A Study of the interaction of radiation and semiconductor lasers: an analysis of transient and permanent effects induced on edge emitting and vertical cavity surface emitting laser diodes

    International Nuclear Information System (INIS)

    Pailharey, Eric

    2000-01-01

    The behavior of laser diodes under transient environment is presented in this work. The first section describes the basic phenomena of radiation interaction with matter. The radiative environments, the main characteristics of laser diodes and the research undertaken on the subject are presented and discussed. The tests on 1300 nm edge emitting laser diode are presented in the second section. The response to a transient ionizing excitation is explored using a 532 nm laser beam. The time of return to steady state after the perturbation is decomposed into several steps: decrease of the optical power during excitation, turn-on delay, relaxation oscillations and optical power offset. Their origins are analyzed using the device structure. To include all the phenomena in a numerical simulation of the device, an individual study of low conductivity materials used for the lateral confinement of the current density is undertaken. The effects of a single particle traversing the optical cavity and an analysis of permanent damages induced by neutrons are also determined. In the last section, 850 nm vertical cavity surface emitting laser diodes (VCSEL) are studied. The behavior of these devices which performances are in constant evolution, is investigated as a function of both temperature and polarization. Then VCSEL are submitted to transient ionizing irradiation and their responses are compared to those of edge emitting diodes. When proton implantation is used in the process, we observe the same behavior for both technologies. VCSEL were submitted to neutron fluence and we have studied the influence of the damages on threshold current, emission patterns and maximum of optical power. (author) [fr

  4. Thermal and physiological responses of rats exposed to 2. 45-GHz radiofrequency radiation: A comparison of E and H orientation

    Energy Technology Data Exchange (ETDEWEB)

    Frei, M.R.; Jauchem, J.R.; Padilla, J.M.; Merritt, J.H.

    1989-07-01

    Ketamine-anesthetized Sprague-Dawley rats were exposed in both E and H orientations to far-field 2.45-GHz continuous-wave radiofrequency radiation (RFR) at a power density of 60 mW/cm/sup 2/ (wholebody average specific absorption rate of approx. = 14 W/kg). Intermittent exposures were performed in both orientations in the same animal to repeatedly increase colonic temperature from 38.5 to 39.5/sup 0/C. Tympanic, subcutaneous (sides toward and away from RFR source), and colonic temperature, ECG, arterial blood pressure, and respiratory rate were continuously recorded. The pattern of heat distribution within the animal and the physiological responses were significantly different between E- and H-orientation exposure. Irradiation in E orientation resulted in greater peripheral and tympanic heating, while irradiation in H orientation resulted in greater core heating. Heart rate and blood pressure increased significantly during irradiation and returned to baseline levels when exposure was discontinued; the increases were significantly greater in E than in H orientation. Respiratory rate increased significantly during irradiation in H, but not in E orientation. The physiological responses could have been influenced by the different levels or rates of subcutaneous and tympanic heating, or the differential between core and peripheral heating during E- and H-orientation irradiation. These results suggest that, when interpreting results of RFR exposure, animal orientation during irradiation must be considered.

  5. Modification in oxidative processes in muscle tissues exposed to laser- and light-emitting diode radiation.

    Science.gov (United States)

    Monich, Victor A; Bavrina, Anna P; Malinovskaya, Svetlana L

    2018-01-01

    Exposure of living tissues to high-intensity red or near-infrared light can produce the oxidative stress effects both in the target zone and adjacent ones. The protein oxidative modification (POM) products can be used as reliable and early markers of oxidative stress. The contents of modified proteins in the investigated specimens can be evaluated by the 2,4-dinitrophenylhydrazine assay (the DNPH assay). Low-intensity red light is able to decrease the activity of oxidative processes and the DNPH assay data about the POM products in the biological tissues could show both an oxidative stress level and an efficiency of physical agent protection against the oxidative processes. Two control groups of white rats were irradiated by laser light, the first control group by red light and the second one by near-infrared radiation (NIR).Two experimental groups were consequently treated with laser and red low-level light-emitting diode radiation (LED). One of them was exposed to red laser light + LED and the other to NIR + LED. The fifth group was intact. Each group included ten animals. The effect of laser light was studied by methods of protein oxidative modifications. We measured levels of both induced and spontaneous POM products by the DNPH assay. The dramatic increase in levels of POM products in the control group samples when compared with the intact group data as well as the sharp decrease in the POM products in the experimental groups treated with LED low-level light were statistically significant (p ≤ 0.05). Exposure of skeletal muscles to high-intensity red and near-infrared laser light causes oxidative stress that continues not less than 3 days. The method of measurement of POM product contents by the DNPH assay is a reliable test of an oxidative process rate. Red low-intensity LED radiation can provide rehabilitation of skeletal muscle tissues treated with high-intensity laser light.

  6. Developing and validating of predictive model for radiofrequency radiation emission within the vicinity of fm stations in Ghana

    International Nuclear Information System (INIS)

    Ahenkora-Duodu, Kingsley

    2016-07-01

    The rapid growing number of FM stations with their corresponding antennas have led to an increase in the concern of the potential health risks that may arise as a result of exposure to RF radiations. The main objective of this research was to develop and validate a predictive model with real time measured data for FM antennas in Ghana. Theoretical and experimental assessment of radiofrequency emission due to FM antennas has been analysed. The maximum and minimum electric field spatial average recorded was 7.17E-01 ± 6.97E-01V/m at Kasapa FM and 6.39E-02 ± 5.39E-02V/m at Asempa FM respectively. At a transmission frequency range of 88 -108 MHz, the average power density of the real time measured data ranged between 3.92E-05W/m"2 and 1.37E-03W/m"2 whiles that of the FM model varied from 9.72E-03W/m"2 to 5.35E-01W/m"2 respectively. Results obtained showed a variation between measured power density levels and the FM model. The FM model overestimates the power density levels as compared to that of the measured data. The impact predictions were based on the maximum values estimated by the FM model, hence these results validates the credibility of the impact analysis for the FM stations. The general public exposure quotient ranged between 9.00E-03 and 2.68E-01 whilst that of the occupational exposure quotient varied from 9.72E-04 to 5.35E-02. The results obtained were found to be in compliance with the International Commission on Non-Ionizing Radiation Protection (ICNIRP) RF exposure limit. (au)

  7. Cost-Effectiveness Analysis of Stereotactic Body Radiation Therapy Compared With Radiofrequency Ablation for Inoperable Colorectal Liver Metastases

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hayeon, E-mail: kimh2@upmc.edu [Department of Radiation Oncology, University of Pittsburgh Cancer Institute, Pittsburgh, Pennsylvania (United States); Gill, Beant; Beriwal, Sushil; Huq, M. Saiful [Department of Radiation Oncology, University of Pittsburgh Cancer Institute, Pittsburgh, Pennsylvania (United States); Roberts, Mark S. [Department of Health Policy and Management, University of Pittsburgh School of Public Health, Pittsburgh, Pennsylvania (United States); Smith, Kenneth J. [Department of Medicine, University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania (United States)

    2016-07-15

    Purpose: To conduct a cost-effectiveness analysis to determine whether stereotactic body radiation therapy (SBRT) is a cost-effective therapy compared with radiofrequency ablation (RFA) for patients with unresectable colorectal cancer (CRC) liver metastases. Methods and Materials: A cost-effectiveness analysis was conducted using a Markov model and 1-month cycle over a lifetime horizon. Transition probabilities, quality of life utilities, and costs associated with SBRT and RFA were captured in the model on the basis of a comprehensive literature review and Medicare reimbursements in 2014. Strategies were compared using the incremental cost-effectiveness ratio, with effectiveness measured in quality-adjusted life years (QALYs). To account for model uncertainty, 1-way and probabilistic sensitivity analyses were performed. Strategies were evaluated with a willingness-to-pay threshold of $100,000 per QALY gained. Results: In base case analysis, treatment costs for 3 fractions of SBRT and 1 RFA procedure were $13,000 and $4397, respectively. Median survival was assumed the same for both strategies (25 months). The SBRT costs $8202 more than RFA while gaining 0.05 QALYs, resulting in an incremental cost-effectiveness ratio of $164,660 per QALY gained. In 1-way sensitivity analyses, results were most sensitive to variation of median survival from both treatments. Stereotactic body radiation therapy was economically reasonable if better survival was presumed (>1 month gain) or if used for large tumors (>4 cm). Conclusions: If equal survival is assumed, SBRT is not cost-effective compared with RFA for inoperable colorectal liver metastases. However, if better local control leads to small survival gains with SBRT, this strategy becomes cost-effective. Ideally, these results should be confirmed with prospective comparative data.

  8. Cost-Effectiveness Analysis of Stereotactic Body Radiation Therapy Compared With Radiofrequency Ablation for Inoperable Colorectal Liver Metastases

    International Nuclear Information System (INIS)

    Kim, Hayeon; Gill, Beant; Beriwal, Sushil; Huq, M. Saiful; Roberts, Mark S.; Smith, Kenneth J.

    2016-01-01

    Purpose: To conduct a cost-effectiveness analysis to determine whether stereotactic body radiation therapy (SBRT) is a cost-effective therapy compared with radiofrequency ablation (RFA) for patients with unresectable colorectal cancer (CRC) liver metastases. Methods and Materials: A cost-effectiveness analysis was conducted using a Markov model and 1-month cycle over a lifetime horizon. Transition probabilities, quality of life utilities, and costs associated with SBRT and RFA were captured in the model on the basis of a comprehensive literature review and Medicare reimbursements in 2014. Strategies were compared using the incremental cost-effectiveness ratio, with effectiveness measured in quality-adjusted life years (QALYs). To account for model uncertainty, 1-way and probabilistic sensitivity analyses were performed. Strategies were evaluated with a willingness-to-pay threshold of $100,000 per QALY gained. Results: In base case analysis, treatment costs for 3 fractions of SBRT and 1 RFA procedure were $13,000 and $4397, respectively. Median survival was assumed the same for both strategies (25 months). The SBRT costs $8202 more than RFA while gaining 0.05 QALYs, resulting in an incremental cost-effectiveness ratio of $164,660 per QALY gained. In 1-way sensitivity analyses, results were most sensitive to variation of median survival from both treatments. Stereotactic body radiation therapy was economically reasonable if better survival was presumed (>1 month gain) or if used for large tumors (>4 cm). Conclusions: If equal survival is assumed, SBRT is not cost-effective compared with RFA for inoperable colorectal liver metastases. However, if better local control leads to small survival gains with SBRT, this strategy becomes cost-effective. Ideally, these results should be confirmed with prospective comparative data.

  9. Occupational exposure of NRM spectrometrists to static and radiofrequency fields

    International Nuclear Information System (INIS)

    Berlana, Tania; Ubeda, Alejandro

    2017-01-01

    Occupational exposure to static and radiofrequency fields emitted by nuclear magnetic resonance spectrometers was assessed through systematic field metering during operation of 19 devices in nine research centers. Whereas no measurable levels of radiofrequency radiation were registered outside the spectrometers, significant exposure to static field was detected, with maximum values recorded at the user s hand (B = 683.00 mT) and head thorax (B = 135.70 mT) during spectrometer manipulation. All values were well below the exposure limits set by the European standard for workers protection against the effects of acute field exposure only. As for potential effects of chronic exposure, waiting for more complete knowledge, adoption of technical and operational strategies for exposure minimizing is advisable. In this respect, the data revealed that compared with standard magnetic shielding, ultra-shield technology allows a 20-65-fold reduction of the field strength received by the operator. (authors)

  10. Measurements of Radiofrequency Radiation with a Body-Borne Exposimeter in Swedish Schools with Wi-Fi

    Directory of Open Access Journals (Sweden)

    Lena K. Hedendahl

    2017-11-01

    Full Text Available IntroductionWireless access to the Internet is now commonly used in schools. Many schools give each student their own laptop and utilize the laptops and wireless fidelity (Wi-Fi connection for educational purposes. Most children also bring their own mobile phones to school. Since children are obliged by law to attend school, a safe environment is important. Lately, it has been discussed if radiofrequency (RF radiation can have long-term adverse effects on children’s health.MethodThis study conducted exposimetric measurements in schools to assess RF emissions in the classroom by measuring the teachers’ RF exposure in order to approximate the children’s exposure. Teachers in grades 7–12 carried a body-borne exposimeter, EME-Spy 200, in school during 1–4 days of work. The exposimeter can measure 20 different frequency bands from 87 to 5,850 MHz.ResultsEighteen teachers from seven schools participated. The mean exposure to RF radiation ranged from 1.1 to 66.1 µW/m2. The highest mean level, 396.6 µW/m2, occurred during 5 min of a lesson when the teacher let the students stream and watch YouTube videos. Maximum peaks went up to 82,857 µW/m2 from mobile phone uplink.DiscussionOur measurements are in line with recent exposure studies in schools in other countries. The exposure levels varied between the different Wi-Fi systems, and if the students were allowed to use their own smartphones on the school’s Wi-Fi network or if they were connected to GSM/3G/4G base stations outside the school. An access point over the teacher’s head gave higher exposure compared with a school with a wired Internet connection for the teacher in the classroom. All values were far below International Commission on Non-Ionizing Radiation Protection’s reference values, but most mean levels measured were above the precautionary target level of 3–6 µW/m2 as proposed by the Bioinitiative Report. The length of time wireless devices are used is an

  11. Infrared light-emitting diode radiation causes gravitropic and morphological effects in dark-grown oat seedlings

    Science.gov (United States)

    Johnson, C. F.; Brown, C. S.; Wheeler, R. M.; Sager, J. C.; Chapman, D. K.; Deitzer, G. F.

    1996-01-01

    Oat (Avena sativa cv Seger) seedlings were irradiated with IR light-emitting diode (LED) radiation passed through a visible-light-blocking filter. Infrared LED irradiated seedlings exhibited differences in growth and gravitropic response when compared to seedlings grown in darkness at the same temperature. Thus, the oat seedlings in this study were able to detect IR LED radiation. These findings call into question the use of IR LED as a safe-light for some photosensitive plant response experiments. These findings also expand the defined range of wavelengths involved in radiation-gravity (light-gravity) interactions to include wavelengths in the IR region of the spectrum.

  12. The effect of electromagnetic radiation emitted by display screens on cell oxygen metabolism - in vitro studies.

    Science.gov (United States)

    Lewicka, Małgorzata; Henrykowska, Gabriela A; Pacholski, Krzysztof; Śmigielski, Janusz; Rutkowski, Maciej; Dziedziczak-Buczyńska, Maria; Buczyński, Andrzej

    2015-12-10

    Research studies carried out for decades have not solved the problem of the effect of electromagnetic radiation of various frequency and strength on the human organism. Due to this fact, we decided to investigate the changes taking place in human blood platelets under the effect of electromagnetic radiation (EMR) emitted by LCD monitors. The changes of selected parameters of oxygen metabolism were measured, i.e. reactive oxygen species concentration, enzymatic activity of antioxidant defence proteins - superoxide dismutase (SOD-1) and catalase (CAT) - and malondialdehyde concentration (MDA). A suspension of human blood platelets was exposed to electromagnetic radiation of 1 kHz frequency and 150 V/m and 220 V/m intensity for 30 and 60 min. The level of changes of the selected parameters of oxidative stress was determined after the exposure and compared to the control samples (not exposed). The measurements revealed an increase of the concentration of reactive oxygen species. The largest increase of ROS concentration vs. the control sample was observed after exposure to EMF of 220 V/m intensity for 60 min (from x = 54.64 to x = 72.92). The measurement of MDA concentration demonstrated a statistically significant increase after 30-min exposure to an EMF of 220 V/m intensity in relation to the initial values (from x = 3.18 to x = 4.41). The enzymatic activity of SOD-1 decreased after exposure (the most prominent change was observed after 60-min and 220 V/m intensity from x = 3556.41 to x = 1084.83). The most significant change in activity of catalase was observed after 60 min and 220 v/m exposure (from x = 6.28 to x = 4.15). The findings indicate that exposure to electromagnetic radiation of 1 kHz frequency and 150 V/m and 220 V/m intensity may cause adverse effects within blood platelets' oxygen metabolism and thus may lead to physiological dysfunction of the organism.

  13. Percutaneous Renal Tumor Ablation: Radiation Exposure During Cryoablation and Radiofrequency Ablation

    Energy Technology Data Exchange (ETDEWEB)

    McEachen, James C., E-mail: james.mceachen2@gmail.com [Mayo Clinic, Division of Preventive, Occupational, and Aerospace Medicine (United States); Leng, Shuai; Atwell, Thomas D. [Mayo Clinic, Department of Radiology (United States); Tollefson, Matthew K. [Mayo Clinic, Department of Urology (United States); Friese, Jeremy L. [Mayo Clinic, Department of Radiology (United States); Wang, Zhen; Murad, M. Hassan [Mayo Clinic, Division of Preventive, Occupational, and Aerospace Medicine (United States); Schmit, Grant D. [Mayo Clinic, Department of Radiology (United States)

    2016-02-15

    IntroductionOnce reserved solely for non-surgical cases, percutaneous ablation is becoming an increasingly popular treatment option for a wider array of patients with small renal masses and the radiation risk needs to be better defined as this transition continues.Materials and MethodsRetrospective review of our renal tumor ablation database revealed 425 patients who underwent percutaneous ablation for treatment of 455 renal tumors over a 5-year time period. Imparted radiation dose information was reviewed for each procedure and converted to effective patient dose and skin dose using established techniques. Statistical analysis was performed with each ablative technique.ResultsFor the 331 cryoablation procedures, the mean DLP was 6987 mGycm (SD = 2861) resulting in a mean effective dose of 104.7 mSv (SD = 43.5) and the mean CTDI{sub vol} was 558 mGy (SD = 439) resulting in a mean skin dose of 563.2 mGy (SD = 344.1). For the 124 RFA procedures, the mean DLP was 3485 mGycm (SD = 1630) resulting in a mean effective dose of 50.3 mSv (SD = 24.0) and the mean CTDI{sub vol} was 232 mGy (SD = 149) resulting in a mean skin dose of 233.2 mGy (SD = 117.4). The difference in patient radiation exposure between the two renal ablation techniques was statistically significant (p < 0.001).ConclusionBoth cryoablation and RFA imparted an average skin dose that was well below the 2 Gy deterministic threshold for appreciable sequela. Renal tumor cryoablation resulted in a mean skin and effective radiation dose more than twice that for RFA. The radiation exposure for both renal tumor ablation techniques was at the high end of the medical imaging radiation dose spectrum.

  14. Estimation of Radiofrequency Power Leakage from Microwave Ovens for Dosimetric Assessment at Nonionizing Radiation Exposure Levels

    Directory of Open Access Journals (Sweden)

    Peio Lopez-Iturri

    2015-01-01

    Full Text Available The electromagnetic field leakage levels of nonionizing radiation from a microwave oven have been estimated within a complex indoor scenario. By employing a hybrid simulation technique, based on coupling full wave simulation with an in-house developed deterministic 3D ray launching code, estimations of the observed electric field values can be obtained for the complete indoor scenario. The microwave oven can be modeled as a time- and frequency-dependent radiating source, in which leakage, basically from the microwave oven door, is propagated along the complete indoor scenario interacting with all of the elements present in it. This method can be of aid in order to assess the impact of such devices on expected exposure levels, allowing adequate minimization strategies such as optimal location to be applied.

  15. Comparative studies of the ITU-T prediction model for radiofrequency radiation emission and real time measurements at some selected mobile base transceiver stations in Accra, Ghana

    International Nuclear Information System (INIS)

    Obeng, S. O

    2014-07-01

    Recent developments in the electronics industry have led to the widespread use of radiofrequency (RF) devices in various areas including telecommunications. The increasing numbers of mobile base station (BTS) as well as their proximity to residential areas have been accompanied by public health concerns due to the radiation exposure. The main objective of this research was to compare and modify the ITU- T predictive model for radiofrequency radiation emission for BTS with measured data at some selected cell sites in Accra, Ghana. Theoretical and experimental assessment of radiofrequency exposures due to mobile base station antennas have been analysed. The maximum and minimum average power density measured from individual base station in the town was 1. 86µW/m2 and 0.00961µW/m2 respectively. The ITU-T Predictive model power density ranged between 6.40mW/m 2 and 0.344W/m 2 . Results obtained showed a variation between measured power density levels and the ITU-T predictive model. The ITU-T model power density levels decrease with increase in radial distance while real time measurements do not due to fluctuations during measurement. The ITU-T model overestimated the power density levels by a factor l0 5 as compared to real time measurements. The ITU-T model was modified to reduce the level of overestimation. The result showed that radiation intensity varies from one base station to another even at the same distance. Occupational exposure quotient ranged between 5.43E-10 and 1.89E-08 whilst general public exposure quotient ranged between 2.72E-09 and 9.44E-08. From the results, it shows that the RF exposure levels in Accra from these mobile phone base station antennas are below the permitted RF exposure limit to the general public recommended by the International Commission on Non-Ionizing Radiation Protection. (au)

  16. Effects of Simultaneous Radiofrequency Radiation and Chemical Exposure of Mammalian Cells. Volume 2

    Science.gov (United States)

    1988-07-01

    chromosome - - - - - - -I aberrations and sister chromatid exchanges (SCE). Yao (1982) exposed rat kangaroo RH5 and RH1l6 cells to 2.45 GHz radiation, and...control was reported in chromosome aberrations. Yac (1982) investigated the cytogenetic consequences of chronic microwave exposure on rat kangaroo RH5...was said to be 280C. The cells were exposed both as conidia, which are "rather inactive metabolically ," and also after DNA replication had been

  17. Decay Curves and Half-Lives of Gamma-Emitting States from a Study of Prompt Fission Gamma Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Albinsson, H [Chalmers Univ. of Technology, Goeteborg (SE)

    1971-04-15

    Measurements were made on the time distributions of the prompt gamma radiation emitted from fragments in the thermal-neutron induced fission of 235U. The gamma radiation emitted during different time intervals after the fission event was studied with the help of a collimator, the position of which was changed along the path of the fragments. In this way decay curves were obtained from which half-lives could be estimated. Time components with half-lives of 7.5, 18 and 60 ps were found and their relative intensities were calculated. Half-lives and associated intensities are in good agreement with earlier data from uranium and californium fission. Problems involved in this type of study are discussed. The collimator technique has proved to be effective for determination of half lives down to less than 10 ps

  18. Numerically stable algorithm for discrete-ordinate-method radiative transfer in multiple scattering and emitting layered media

    Science.gov (United States)

    Stamnes, Knut; Tsay, S.-CHEE; Jayaweera, Kolf; Wiscombe, Warren

    1988-01-01

    The transfer of monochromatic radiation in a scattering, absorbing, and emitting plane-parallel medium with a specified bidirectional reflectivity at the lower boundary is considered. The equations and boundary conditions are summarized. The numerical implementation of the theory is discussed with attention given to the reliable and efficient computation of eigenvalues and eigenvectors. Ways of avoiding fatal overflows and ill-conditioning in the matrix inversion needed to determine the integration constants are also presented.

  19. Evaluation of scattered radiation emitted from X-ray security scanners on occupational dose to airport personnel

    International Nuclear Information System (INIS)

    Dalah, Entesar; Fakhry, Angham; Mukhtar, Asma; Al Salti, Farah; Bader, May; Khouri, Sara; Al-Zahmi, Reem

    2017-01-01

    Based on security issues and regulations airports are provided with luggage cargo scanners. These scanners utilize ionizing radiation that in principle present health risks toward humans. The study aims to investigate the amount of backscatter produced by passenger luggage and cargo toward airport personnel who are located at different distances from the scanners. To approach our investigation a Thermo Electron Radeye-G probe was used to quantify the backscattered radiation measured in terms of dose-rate emitted from airport scanners, Measurements were taken at the entrance and exit positions of the X-ray tunnel at three different distances (0, 50, and 100 cm) for two different scanners; both scanners include shielding curtains that reduce scattered radiation. Correlation was demonstrated using the Pearson coefficient test. Measurements confirmed an inverse relationship between dose rate and distance. An estimated occupational accumulative dose of 0.88 mSv/y, and 2.04 mSv/y were obtained for personnel working in inspection of carry-on, and cargo, respectively. Findings confirm that the projected dose of security and engineering staff are being well within dose limits. - Highlights: • Backscattered radiation emitted from the airport security scanners is estimated. • Inverse relation observed between backscattered radiation and scanners distance. • Occupational dose for personnel inspecting the scanners were up to 2.04 mSv/y. • The projected dose of security and engineering staff are well within dose limits.

  20. Estimation of soft X-ray and EUV transition radiation power emitted from the MIRRORCLE-type tabletop synchrotron.

    Science.gov (United States)

    Toyosugi, N; Yamada, H; Minkov, D; Morita, M; Yamaguchi, T; Imai, S

    2007-03-01

    The tabletop synchrotron light sources MIRRORCLE-6X and MIRRORCLE-20SX, operating at electron energies E(el) = 6 MeV and E(el) = 20 MeV, respectively, can emit powerful transition radiation (TR) in the extreme ultraviolet (EUV) and the soft X-ray regions. To clarify the applicability of these soft X-ray and EUV sources, the total TR power has been determined. A TR experiment was performed using a 385 nm-thick Al foil target in MIRRORCLE-6X. The angular distribution of the emitted power was measured using a detector assembly based on an NE102 scintillator, an optical bundle and a photomultiplier. The maximal measured total TR power for MIRRORCLE-6X is P(max) approximately equal 2.95 mW at full power operation. Introduction of an analytical expression for the lifetime of the electron beam allows calculation of the emitted TR power by a tabletop synchrotron light source. Using the above measurement result, and the theoretically determined ratio between the TR power for MIRRORCLE-6X and MIRRORCLE-20SX, the total TR power for MIRRORCLE-20SX can be obtained. The one-foil TR target thickness is optimized for the 20 MeV electron energy. P(max) approximately equal 810 mW for MIRRORCLE-20SX is obtained with a single foil of 240 nm-thick Be target. The emitted bremsstrahlung is negligible with respect to the emitted TR for optimized TR targets. From a theoretically known TR spectrum it is concluded that MIRRORCLE-20SX can emit 150 mW of photons with E > 500 eV, which makes it applicable as a source for performing X-ray lithography. The average wavelength, \\overline\\lambda = 13.6 nm, of the TR emission of MIRRORCLE-20SX, with a 200 nm Al target, could provide of the order of 1 W EUV.

  1. Assessment of radiation emitted by the colour video monitors using a silicon surface-barrier detection system

    International Nuclear Information System (INIS)

    Tykva, R.; Sabol, J.

    1998-01-01

    About 5% of the commonly used colour monitors tested showed radiation levels on the screen surface approaching the dose rate of 5 μGy/h. There is practically no difference between 'low radiation' monitors and other monitors. The level of radiation emitted to the sides is generally higher than that of X-ray photons emerging from the surface of the screen. Although the contribution to the effective dose of a person exposed to radiation from the monitors may be below the limit set for the general public, the skin and eye lens dose may reach significant levels, taking into account some factors such as a high density of monitors in small rooms, short distance, long exposure time, etc. (M.D.)

  2. Enhancement of chemically induced reactive oxygen species production and DNA damage in human SH-SY5Y neuroblastoma cells by 872 MHz radiofrequency radiation

    Energy Technology Data Exchange (ETDEWEB)

    Luukkonen, Jukka [Department of Environmental Science, University of Kuopio, Bioteknia 2, P.O. Box 1627, FI-70211 Kuopio (Finland)], E-mail: Jukka.Luukkonen@uku.fi; Hakulinen, Pasi; Maeki-Paakkanen, Jorma [Department of Environmental Health, National Public Health Institute, P.O. Box 95, FI-70701 Kuopio (Finland); Juutilainen, Jukka; Naarala, Jonne [Department of Environmental Science, University of Kuopio, Bioteknia 2, P.O. Box 1627, FI-70211 Kuopio (Finland)

    2009-03-09

    The objective of the study was to investigate effects of 872 MHz radiofrequency (RF) radiation on intracellular reactive oxygen species (ROS) production and DNA damage at a relatively high SAR value (5 W/kg). The experiments also involved combined exposure to RF radiation and menadione, a chemical inducing intracellular ROS production and DNA damage. The production of ROS was measured using the fluorescent probe dichlorofluorescein and DNA damage was evaluated by the Comet assay. Human SH-SY5Y neuroblastoma cells were exposed to RF radiation for 1 h with or without menadione. Control cultures were sham exposed. Both continuous waves (CW) and a pulsed signal similar to that used in global system for mobile communications (GSM) mobile phones were used. Exposure to the CW RF radiation increased DNA breakage (p < 0.01) in comparison to the cells exposed only to menadione. Comparison of the same groups also showed that ROS level was higher in cells exposed to CW RF radiation at 30 and 60 min after the end of exposure (p < 0.05 and p < 0.01, respectively). No effects of the GSM signal were seen on either ROS production or DNA damage. The results of the present study suggest that 872 MHz CW RF radiation at 5 W/kg might enhance chemically induced ROS production and thus cause secondary DNA damage. However, there is no known mechanism that would explain such effects from CW RF radiation but not from GSM modulated RF radiation at identical SAR.

  3. Enhancement of chemically induced reactive oxygen species production and DNA damage in human SH-SY5Y neuroblastoma cells by 872 MHz radiofrequency radiation

    International Nuclear Information System (INIS)

    Luukkonen, Jukka; Hakulinen, Pasi; Maeki-Paakkanen, Jorma; Juutilainen, Jukka; Naarala, Jonne

    2009-01-01

    The objective of the study was to investigate effects of 872 MHz radiofrequency (RF) radiation on intracellular reactive oxygen species (ROS) production and DNA damage at a relatively high SAR value (5 W/kg). The experiments also involved combined exposure to RF radiation and menadione, a chemical inducing intracellular ROS production and DNA damage. The production of ROS was measured using the fluorescent probe dichlorofluorescein and DNA damage was evaluated by the Comet assay. Human SH-SY5Y neuroblastoma cells were exposed to RF radiation for 1 h with or without menadione. Control cultures were sham exposed. Both continuous waves (CW) and a pulsed signal similar to that used in global system for mobile communications (GSM) mobile phones were used. Exposure to the CW RF radiation increased DNA breakage (p < 0.01) in comparison to the cells exposed only to menadione. Comparison of the same groups also showed that ROS level was higher in cells exposed to CW RF radiation at 30 and 60 min after the end of exposure (p < 0.05 and p < 0.01, respectively). No effects of the GSM signal were seen on either ROS production or DNA damage. The results of the present study suggest that 872 MHz CW RF radiation at 5 W/kg might enhance chemically induced ROS production and thus cause secondary DNA damage. However, there is no known mechanism that would explain such effects from CW RF radiation but not from GSM modulated RF radiation at identical SAR

  4. Assessment of magnetic field interactions and radiofrequency-radiation-induced heating of metallic spinal implants in 7 T field.

    Science.gov (United States)

    Tsukimura, Itsuko; Murakami, Hideki; Sasaki, Makoto; Endo, Hirooki; Yamabe, Daisuke; Oikawa, Ryosuke; Doita, Minoru

    2017-08-01

    The safety of metallic spinal implants in magnetic resonance imaging (MRI) performed using ultrahigh fields has not been established. Hence, we examined whether the displacement forces caused by a static magnetic field and the heating induced by radiofrequency radiation are substantial for spinal implants in a 7 T field. We investigated spinal rods of various lengths and materials, a screw, and a cross-linking bridge in accordance with the American Society for Testing and Materials guidelines. The displacement forces of the metallic implants in static 7 T and 3 T static magnetic fields were measured and compared. The temperature changes of the implants during 15-min-long fast spin-echo and balanced gradient-echo image acquisition sequences were measured in the 7 T field. The deflection angles of the metallic spinal materials in the 7 T field were 5.0-21.0° [median: 6.7°], significantly larger than those in the 3 T field (1.0-6.3° [2.2°]). Among the metallic rods, the cobalt-chrome rods had significantly larger deflection angles (17.8-21.0° [19.8°]) than the pure titanium and titanium alloy rods (5.0-7.7° [6.2°]). The temperature changes of the implants, including the cross-linked rods, were 0.7-1.0°C [0.8°C] and 0.6-1.0°C [0.7°C] during the fast spin-echo and balanced gradient-echo sequences, respectively; these changes were slightly larger than those of the controls (0.4-1.1°C [0.5°C] and 0.3-0.9°C [0.6°C], respectively). All of the metallic spinal implants exhibited small displacement forces and minimal heating, indicating that MRI examinations using 7 T fields may be performed safely on patients with these implants. © 2016 The Authors. Journal of Orthopaedic Research Published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society. J Orthop Res 35:1831-1837, 2017. © 2016 The Authors. Journal of Orthopaedic Research Published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society.

  5. Optical spectroscopy and microscopy of radiation-induced light-emitting point defects in lithium fluoride crystals and films

    Science.gov (United States)

    Montereali, R. M.; Bonfigli, F.; Menchini, F.; Vincenti, M. A.

    2012-08-01

    Broad-band light-emitting radiation-induced F2 and F3+ electronic point defects, which are stable and laser-active at room temperature in lithium fluoride crystals and films, are used in dosimeters, tuneable color-center lasers, broad-band miniaturized light sources and novel radiation imaging detectors. A brief review of their photoemission properties is presented, and their behavior at liquid nitrogen temperatures is discussed. Some experimental data from optical spectroscopy and fluorescence microscopy of these radiation-induced point defects in LiF crystals and thin films are used to obtain information about the coloration curves, the efficiency of point defect formation, the effects of photo-bleaching processes, etc. Control of the local formation, stabilization, and transformation of radiation-induced light-emitting defect centers is crucial for the development of optically active micro-components and nanostructures. Some of the advantages of low temperature measurements for novel confocal laser scanning fluorescence microscopy techniques, widely used for spatial mapping of these point defects through the optical reading of their visible photoluminescence, are highlighted.

  6. Combined Natural Convection and Radiation Heat Transfer of Various Absorbing-Emitting-Scattering Media in a Square Cavity

    Directory of Open Access Journals (Sweden)

    Xianglong Liu

    2014-01-01

    Full Text Available A numerical model is developed to simulate combined natural convection and radiation heat transfer of various anisotropic absorbing-emitting-scattering media in a 2D square cavity based on the discrete ordinate (DO method and Boussinesq assumption. The effects of Rayleigh number, optical thickness, scattering ratio, scattering phase function, and aspect ratio of square cavity on the behaviors of heat transfer are studied. The results show that the heat transfer of absorbing-emitting-scattering media is the combined results of radiation and natural convection, which depends on the physical properties and the aspect ratio of the cavity. When the natural convection becomes significant, the convection heat transfer is enhanced, and the distributions of NuR and Nuc along the walls are obviously distorted. As the optical thickness increases, NuR along the hot wall decreases. As the scattering ratio decreases, the NuR along the walls decreases. At the higher aspect ratio, the more intensive thermal radiation and natural convection are formed, which increase the radiation and convection heat fluxes. This paper provides the theoretical research for the optimal thermal design and practical operation of the high temperature industrial equipments.

  7. X-ray Emitting GHz-Peaked Spectrum Galaxies: Testing a Dynamical-Radiative Model with Broad-Band Spectra

    International Nuclear Information System (INIS)

    Ostorero, L.; Moderski, R.; Stawarz, L.; Diaferio, A.; Kowalska, I.; Cheung, C.C.; Kataoka, J.; Begelman, M.C.; Wagner, S.J.

    2010-01-01

    In a dynamical-radiative model we recently developed to describe the physics of compact, GHz-Peaked-Spectrum (GPS) sources, the relativistic jets propagate across the inner, kpc-sized region of the host galaxy, while the electron population of the expanding lobes evolves and emits synchrotron and inverse-Compton (IC) radiation. Interstellar-medium gas clouds engulfed by the expanding lobes, and photoionized by the active nucleus, are responsible for the radio spectral turnover through free-free absorption (FFA) of the synchrotron photons. The model provides a description of the evolution of the GPS spectral energy distribution (SED) with the source expansion, predicting significant and complex high-energy emission, from the X-ray to the γ-ray frequency domain. Here, we test this model with the broad-band SEDs of a sample of eleven X-ray emitting GPS galaxies with Compact-Symmetric-Object (CSO) morphology, and show that: (i) the shape of the radio continuum at frequencies lower than the spectral turnover is indeed well accounted for by the FFA mechanism; (ii) the observed X-ray spectra can be interpreted as non-thermal radiation produced via IC scattering of the local radiation fields off the lobe particles, providing a viable alternative to the thermal, accretion-disk dominated scenario. We also show that the relation between the hydrogen column densities derived from the X-ray (N H ) and radio (N HI ) data of the sources is suggestive of a positive correlation, which, if confirmed by future observations, would provide further support to our scenario of high-energy emitting lobes.

  8. International radiofrequency standards

    International Nuclear Information System (INIS)

    Lincoln, J.

    2001-01-01

    Of the various radiofrequency standards in use around the world, many are based on or similar to the Guidelines published by ICNIRP (The International Commission on Non-ionising Radiation Protection). This organisation is a working group operating in co-operation with the Environmental Health division of the World Health Organisation (WHO). This paper presents a very brief overview of current international standards, beginning with a summary of the salient points of the ICNIRP Guidelines. It should be remembered that these are guidelines only and do not exist as a separate standard. Copyright (2001) Australasian Radiation Protection Society Inc

  9. Childhood leukaemia in relation to radiofrequency electromagnetic fields emitted from television and radio broadcast transmitters: epidemiological aspects of a case-control study in Germany; Leukaemie bei Kindern in der Umgebung von Sendestationen des Rundfunks. Anforderungen an das Studiendesign

    Energy Technology Data Exchange (ETDEWEB)

    Merzenich, H.; Bennack, S.; Blettner, M. [Mainz Univ. (DE). Inst. fuer Medizinische Biometrie, Epidemiologie und Informatik (IMBEI); Schmiedel, S.; Schuez, J. [Mainz Univ. (DE). Inst. fuer Medizinische Biometrie, Epidemiologie und Informatik (IMBEI); Danish Cancer Society, Copenhagen (Denmark). Inst. of Cancer Epidemiology; Brueggemeyer, H. [Niedersaechsischer Landesbetrieb fuer Wasserwirtschaft, Kuesten- und Naturschutz, AB35 - Strahlenschutz in Niedersachsen, Hannover (Germany); Philipp, J. [Suedwestrundfunk, Stuttgart (Germany). Abt. Frequenz- und Versorgungsplanung; Spix, C. [Mainz Univ. (Germany). Deutsches Kinderkrebsregister

    2007-07-01

    Leukaemia is the most common type of cancer in children accounting for about a third of all cancers in children under the age of 15 years. Environmental factors such as non-ionising radiation exposure might play a role in the aetiology of childhood leukaemia. However, data to support such hypotheses are inconsistent. A case control study has been set up in West Germany (University of Mainz) in order to determine whether there is an increased risk of childhood leukaemia in populations exposed to radiofrequency electromagnetic fields from TV and/or Radio towers. Cases are children aged 0 to 14 years with a primary leukaemia diagnosed between 1984 and 2003 who lived in the vicinity of these TV- and/ or Radio towers. Cases have been identified through the German Childhood Cancer Registry. Three controls per case have been individually matched by age at diagnosis, sex, time of diagnosis and study area. The study focuses on an individual retrospective exposure assessment using data from transmitter network operators. The study has started in March 2005 with a pilot investigation in order to specify the study design and the methods for exposure assessment. A total of 2009 eligible cases have been identified. The study will be finished end of 2007. (orig.)

  10. High-energy coherent terahertz radiation emitted by wide-angle electron beams from a laser-wakefield accelerator

    Science.gov (United States)

    Yang, Xue; Brunetti, Enrico; Jaroszynski, Dino A.

    2018-04-01

    High-charge electron beams produced by laser-wakefield accelerators are potentially novel, scalable sources of high-power terahertz radiation suitable for applications requiring high-intensity fields. When an intense laser pulse propagates in underdense plasma, it can generate femtosecond duration, self-injected picocoulomb electron bunches that accelerate on-axis to energies from 10s of MeV to several GeV, depending on laser intensity and plasma density. The process leading to the formation of the accelerating structure also generates non-injected, sub-picosecond duration, 1–2 MeV nanocoulomb electron beams emitted obliquely into a hollow cone around the laser propagation axis. These wide-angle beams are stable and depend weakly on laser and plasma parameters. Here we perform simulations to characterise the coherent transition radiation emitted by these beams if passed through a thin metal foil, or directly at the plasma–vacuum interface, showing that coherent terahertz radiation with 10s μJ to mJ-level energy can be produced with an optical to terahertz conversion efficiency up to 10‑4–10‑3.

  11. Finite volume method for radiative heat transfer in an unstructured flow solver for emitting, absorbing and scattering media

    International Nuclear Information System (INIS)

    Gazdallah, Moncef; Feldheim, Véronique; Claramunt, Kilian; Hirsch, Charles

    2012-01-01

    This paper presents the implementation of the finite volume method to solve the radiative transfer equation in a commercial code. The particularity of this work is that the method applied on unstructured hexahedral meshes does not need a pre-processing step establishing a particular marching order to visit all the control volumes. The solver simply visits the faces of the control volumes as numbered in the hexahedral unstructured mesh. A cell centred mesh and a spatial differencing step scheme to relate facial radiative intensities to nodal intensities is used. The developed computer code based on FVM has been integrated in the CFD solver FINE/Open from NUMECA Int. Radiative heat transfer can be evaluated within systems containing uniform, grey, emitting, absorbing and/or isotropically or linear anisotropically scattering medium bounded by diffuse grey walls. This code has been validated for three test cases. The first one is a three dimensional rectangular enclosure filled with emitting, absorbing and anisotropically scattering media. The second is the differentially heated cubic cavity. The third one is the L-shaped enclosure. For these three test cases a good agreement has been observed when temperature and heat fluxes predictions are compared with references taken, from literature.

  12. Effect of Mobile Phone Radiofrequency Electromagnetic Fields on ...

    African Journals Online (AJOL)

    olayemitoyin

    Summary: Since cell phones emit radiofrequency electromagnetic fields (EMFs), this study tested the hypothesis that cell phones placed ... mobile phones on autonomic modulation of the heart. ..... Electrocardiogram and Its Technology. J. Am.

  13. Volatiles emitted from flowers of gamma-radiated and nonradiated Jasminum polyanthum Franch

    DEFF Research Database (Denmark)

    Christensen, Lars P; Jakobsen, Henrik B; Kristiansen, Kell

    1997-01-01

    Volatile compounds emitted from flowers of Jasminum polyanthum Pepita in situ were collected by dynamic headspace technique and analyzed by GC-FID and GC-MS. A total of 32 compounds were identified. The flower scent was dominated by benzyl acetate (57.8%), p-cresol (12.2%), (E)-isoeugenol (9.7%),...

  14. Preliminary results on soil-emitted gamma radiation and its relation with the local atmospheric electric field at Amieira (Portugal)

    International Nuclear Information System (INIS)

    Lopes, F; Barbosa, S M; Silva, H G; Bárias, S

    2015-01-01

    The atmospheric electric field near the Earth's surface is dominated by atmospheric pollutants and natural radioactivity, with the latter directly linked to radon ( 222 Rn) gas. For a better comprehension on the temporal variability of both the atmospheric electric field and the radon concentration and its relation with local atmospheric variables, simultaneous measurements of soil-emitted gamma radiation and potential gradient (defined from the vertical component of the atmospheric electric field) were taken every minute, along with local meteorological parameters (e.g., temperature, atmospheric pressure, relative humidity and daily solar radiation). The study region is Amieira, part of the Alqueva lake in Alentejo Portugal, where an interdisciplinary meteorological campaign, ALEX2014, took place from June to August 2014. Soil gamma radiation is more sensitive to small concentrations of radon as compared with alpha particles measurements, for that reason it is more suited for sites with low radon levels, as expected in this case. Preliminary results are presented here: statistical and spectral analysis show that i) the potential gradient has a stronger daily cycle as compared with the gamma radiation, ii) most of the energy of the gamma signal is concentrated in the low frequencies (close to 0), contrary to the potential gradient that has most of the energy in frequency 1 (daily cycle) and iii) a short-term relation between gamma radiation and the potential gradient has not been found. Future work and plans are also discussed. (paper)

  15. Radiofrequency fields in our surroundings

    International Nuclear Information System (INIS)

    2011-01-01

    In 2010, the National Radiation Protection Authority (NRPA) with the Post and Telecommunications Authority carried out a project where it is measured radiofrequency fields from various telecom systems in homes, kindergartens, schools, offices, and urban environments. Close to 99 percent of the measurement points were found values of less than one thousandth of the maximum. No values were near the limits. (AG)

  16. Oxidative stress response in SH-SY5Y cells exposed to short-term 1800 MHz radiofrequency radiation.

    Science.gov (United States)

    Marjanovic Cermak, Ana Marija; Pavicic, Ivan; Trosic, Ivancica

    2018-01-28

    The exact mechanism that could explain the effects of radiofrequency (RF) radiation exposure at non-thermal level is still unknown. Increasing evidence suggests a possible involvement of reactive oxygen species (ROS) and development of oxidative stress. To test the proposed hypothesis, human neuroblastoma cells (SH-SY5Y) were exposed to 1800 MHz short-term RF exposure for 10, 30 and 60 minutes. Electric field strength within Gigahertz Transverse Electromagnetic cell (GTEM) was 30 V m -1 and specific absorption rate (SAR) was calculated to be 1.6 W kg -1 . Cellular viability was measured by MTT assay and level of ROS was determined by fluorescent probe 2',7'-dichlorofluorescin diacetate. Concentrations of malondialdehyde and protein carbonyls were used to assess lipid and protein oxidative damage and antioxidant activity was evaluated by measuring concentrations of total glutathione (GSH). After radiation exposure, viability of irradiated cells remained within normal physiological values. Significantly higher ROS level was observed for every radiation exposure time. After 60 min of exposure, the applied radiation caused significant lipid and protein damage. The highest GSH concentration was detected after 10 minute-exposure. The results of our study showed enhanced susceptibility of SH-SY5Y cells for development of oxidative stress even after short-term RF exposure.

  17. Radiation Exposure of Interventional Radiologists During Computed Tomography Fluoroscopy-Guided Renal Cryoablation and Lung Radiofrequency Ablation: Direct Measurement in a Clinical Setting

    Energy Technology Data Exchange (ETDEWEB)

    Matsui, Yusuke, E-mail: wckyh140@yahoo.co.jp; Hiraki, Takao, E-mail: takaoh@tc4.so-net.ne.jp; Gobara, Hideo, E-mail: gobara@cc.okayama-u.ac.jp; Iguchi, Toshihiro, E-mail: i10476@yahoo.co.jp; Fujiwara, Hiroyasu, E-mail: hirofujiwar@gmail.com; Kawabata, Takahiro, E-mail: tkhr-kwbt@yahoo.co.jp [Okayama University Medical School, Department of Radiology (Japan); Yamauchi, Takatsugu, E-mail: me9248@hp.okayama-u.ac.jp; Yamaguchi, Takuya, E-mail: me8738@hp.okayama-u.ac.jp [Okayama University Hospital, Central Division of Radiology (Japan); Kanazawa, Susumu, E-mail: susumu@cc.okayama-u.ac.jp [Okayama University Medical School, Department of Radiology (Japan)

    2016-06-15

    IntroductionComputed tomography (CT) fluoroscopy-guided renal cryoablation and lung radiofrequency ablation (RFA) have received increasing attention as promising cancer therapies. Although radiation exposure of interventional radiologists during these procedures is an important concern, data on operator exposure are lacking.Materials and MethodsRadiation dose to interventional radiologists during CT fluoroscopy-guided renal cryoablation (n = 20) and lung RFA (n = 20) was measured prospectively in a clinical setting. Effective dose to the operator was calculated from the 1-cm dose equivalent measured on the neck outside the lead apron, and on the left chest inside the lead apron, using electronic dosimeters. Equivalent dose to the operator’s finger skin was measured using thermoluminescent dosimeter rings.ResultsThe mean (median) effective dose to the operator per procedure was 6.05 (4.52) μSv during renal cryoablation and 0.74 (0.55) μSv during lung RFA. The mean (median) equivalent dose to the operator’s finger skin per procedure was 2.1 (2.1) mSv during renal cryoablation, and 0.3 (0.3) mSv during lung RFA.ConclusionRadiation dose to interventional radiologists during renal cryoablation and lung RFA were at an acceptable level, and in line with recommended dose limits for occupational radiation exposure.

  18. Radiation Exposure of Interventional Radiologists During Computed Tomography Fluoroscopy-Guided Renal Cryoablation and Lung Radiofrequency Ablation: Direct Measurement in a Clinical Setting.

    Science.gov (United States)

    Matsui, Yusuke; Hiraki, Takao; Gobara, Hideo; Iguchi, Toshihiro; Fujiwara, Hiroyasu; Kawabata, Takahiro; Yamauchi, Takatsugu; Yamaguchi, Takuya; Kanazawa, Susumu

    2016-06-01

    Computed tomography (CT) fluoroscopy-guided renal cryoablation and lung radiofrequency ablation (RFA) have received increasing attention as promising cancer therapies. Although radiation exposure of interventional radiologists during these procedures is an important concern, data on operator exposure are lacking. Radiation dose to interventional radiologists during CT fluoroscopy-guided renal cryoablation (n = 20) and lung RFA (n = 20) was measured prospectively in a clinical setting. Effective dose to the operator was calculated from the 1-cm dose equivalent measured on the neck outside the lead apron, and on the left chest inside the lead apron, using electronic dosimeters. Equivalent dose to the operator's finger skin was measured using thermoluminescent dosimeter rings. The mean (median) effective dose to the operator per procedure was 6.05 (4.52) μSv during renal cryoablation and 0.74 (0.55) μSv during lung RFA. The mean (median) equivalent dose to the operator's finger skin per procedure was 2.1 (2.1) mSv during renal cryoablation, and 0.3 (0.3) mSv during lung RFA. Radiation dose to interventional radiologists during renal cryoablation and lung RFA were at an acceptable level, and in line with recommended dose limits for occupational radiation exposure.

  19. Natural and gamma radiation-induced conduction of silica and metaphosphate glass layers deposed by radiofrequency cathode sputtering

    International Nuclear Information System (INIS)

    Serra, Andre

    1977-01-01

    We present a study of natural and 60 Co induced conductions in radiofrequency sputtering deposed layers. Capacimetry and electronic microscopy observations permit a knowledge of the physical characteristics, mainly: homogeneity and thickness of these layers. A study of the natural current permit to characterise electrically the deposited films, the electrode and bulk insulator effects. In induced conduction, the behaviour of currents as a function of dose rate is interpreted in terms of ROSE'S and FOWLER'S photoconductivity theories. Induced currents versus applied fields are observed and compared with these obtained in the case of dielectric liquids and glasses. (author) [fr

  20. Development of computational pregnant female and fetus models and assessment of radiation dose from positron-emitting tracers

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Tianwu [Geneva University Hospital, Division of Nuclear Medicine and Molecular Imaging, Geneva (Switzerland); Zaidi, Habib [Geneva University Hospital, Division of Nuclear Medicine and Molecular Imaging, Geneva (Switzerland); Geneva University, Geneva Neuroscience Center, Geneva (Switzerland); University of Groningen, University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University of Southern Denmark, Department of Nuclear Medicine, Odense (Denmark)

    2016-12-15

    Molecular imaging using PET and hybrid (PET/CT and PET/MR) modalities nowadays plays a pivotal role in the clinical setting for diagnosis and staging, treatment response monitoring, and radiation therapy treatment planning of a wide range of oncologic malignancies. The developing embryo/fetus presents a high sensitivity to ionizing radiation. Therefore, estimation of the radiation dose delivered to the embryo/fetus and pregnant patients from PET examinations to assess potential radiation risks is highly praised. We constructed eight embryo/fetus models at various gestation periods with 25 identified tissues according to reference data recommended by the ICRP publication 89 representing the anatomy of the developing embryo/fetus. The developed embryo/fetus models were integrated into realistic anthropomorphic computational phantoms of the pregnant female and used for estimating, using Monte Carlo calculations, S-values of common positron-emitting radionuclides, organ absorbed dose, and effective dose of a number of positron-emitting labeled radiotracers. The absorbed dose is nonuniformly distributed in the fetus. The absorbed dose of the kidney and liver of the 8-week-old fetus are about 47.45 % and 44.76 % higher than the average absorbed dose of the fetal total body for all investigated radiotracers. For {sup 18}F-FDG, the fetal effective doses are 2.90E-02, 3.09E-02, 1.79E-02, 1.59E-02, 1.47E-02, 1.40E-02, 1.37E-02, and 1.27E-02 mSv/MBq at the 8th, 10th, 15th, 20th, 25th, 30th, 35th, and 38th weeks of gestation, respectively. The developed pregnant female/fetus models matching the ICRP reference data can be exploited by dedicated software packages for internal and external dose calculations. The generated S-values will be useful to produce new standardized dose estimates to pregnant patients and embryo/fetus from a variety of positron-emitting labeled radiotracers. (orig.)

  1. Influence of radiation-dose pattern from inhaled beta--gamma-emitting radionuclides on canine peripheral lymphocytes

    International Nuclear Information System (INIS)

    Jones, R.K.; Boecker, B.B.; Pickrell, J.A.; Hobbs, C.H.; McClellan, R.O.

    1976-01-01

    As part of studies assess the biological hazards associated with inhaled radionuclides, periodic hematologic evaluations were performed on beagle dogs given a single nose-only exposure to aerosols of beta--gamma-emitting isotopes. The physical form and specific radionuclides selected produced radiation-dose patterns representative of those which might be encountered in the event of human accidental exposures. Dogs received graded lung burdens of either 90 Y, 91 Y, 144 Ce, or 90 Sr, each in fused clay. Differences in the effective half-lives of these radionuclides resulted in a spectrum of cumulative radiation doses to lung delivered at a variety of dose rates. Since the form in which the radionuclides were inhaled was relatively insoluble, the lung and intrathoracic tissues represented the primary recipient of the dose. Regardless of the effective half-life of radionuclide retention, a dose-related depression of peripheral lymphocytes was observed at various times after inhalation exposure. The time at which maximum depression and subsequent recovery occurred, however, was most directly related to the effective half-life of the radionuclide. Of special interest was the persistence of lymphopenia through 2 1 / 2 years after exposure to 144 Ce and 90 Sr in fused clay where, other than tracheobronchial lymph nodes, the lymphoid tissue received very little radiation dose. The possible mechanisms responsible for lymphocyte depression from these various radiation-dose patterns are discussed

  2. Overview of a benefit/risk ratio optimized for a radiation emitting device used in non-destructive testing

    Energy Technology Data Exchange (ETDEWEB)

    Maharaj, H.P., E-mail: H_P_Maharaj@hc-sc.gc.ca [Health Canada, Dept. of Health, Consumer and Clinical Radiaton Protection Bureau, Ottawa, Ontario (Canada)

    2016-03-15

    This paper aims to provide an overview of an optimized benefit/risk ratio for a radiation emitting device. The device, which is portable, hand-held, and open-beam x-ray tube based, is utilized by a wide variety of industries for purposes of determining elemental or chemical analyses of materials in-situ based on fluorescent x-rays. These analyses do not cause damage or permanent alteration of the test materials and are considered a non-destructive test (NDT). Briefly, the key characteristics, principles of use and radiation hazards associated with the Hay device are presented and discussed. In view of the potential radiation risks, a long term strategy that incorporates risk factors and guiding principles intended to mitigate the radiation risks to the end user was considered and applied. Consequently, an operator certification program was developed on the basis of an International Standards Organization (ISO) standard (ISO 20807:2004) and in collaboration with various stake holders and was implemented by a federal national NDT certification body several years ago. It comprises a written radiation safety examination and hands-on training with the x-ray device. The operator certification program was recently revised and the changes appear beneficial. There is a fivefold increase in operator certification (Levels 1 a nd 2) to date compared with earlier years. Results are favorable and promising. An operational guidance document is available to help mitigate radiation risks. Operator certification in conjunction with the use of the operational guidance document is prudent, and is recommended for end users of the x-ray device. Manufacturers and owners of the x-ray devices will also benefit from the operational guidance document. (author)

  3. Overview of a benefit/risk ratio optimized for a radiation emitting device used in non-destructive testing

    International Nuclear Information System (INIS)

    Maharaj, H.P.

    2016-01-01

    This paper aims to provide an overview of an optimized benefit/risk ratio for a radiation emitting device. The device, which is portable, hand-held, and open-beam x-ray tube based, is utilized by a wide variety of industries for purposes of determining elemental or chemical analyses of materials in-situ based on fluorescent x-rays. These analyses do not cause damage or permanent alteration of the test materials and are considered a non-destructive test (NDT). Briefly, the key characteristics, principles of use and radiation hazards associated with the Hay device are presented and discussed. In view of the potential radiation risks, a long term strategy that incorporates risk factors and guiding principles intended to mitigate the radiation risks to the end user was considered and applied. Consequently, an operator certification program was developed on the basis of an International Standards Organization (ISO) standard (ISO 20807:2004) and in collaboration with various stake holders and was implemented by a federal national NDT certification body several years ago. It comprises a written radiation safety examination and hands-on training with the x-ray device. The operator certification program was recently revised and the changes appear beneficial. There is a fivefold increase in operator certification (Levels 1 a nd 2) to date compared with earlier years. Results are favorable and promising. An operational guidance document is available to help mitigate radiation risks. Operator certification in conjunction with the use of the operational guidance document is prudent, and is recommended for end users of the x-ray device. Manufacturers and owners of the x-ray devices will also benefit from the operational guidance document. (author)

  4. Cytogenetic studies in human blood lymphocytes exposed in vitro to radiofrequency radiation at a cellular telephone frequency (835.62 MHz, FDMA).

    Science.gov (United States)

    Vijayalaxmi; Leal, B Z; Meltz, M L; Pickard, W F; Bisht, K S; Roti Roti JL; Straube, W L; Moros, E G

    2001-01-01

    Freshly collected peripheral blood samples from four healthy human volunteers were diluted with RPMI 1640 tissue culture medium and exposed in sterile T-75 tissue culture flasks in vitro for 24 h to 835.62 MHz radiofrequency (RF) radiation, a frequency employed for customer-to-base station transmission of cellular telephone communications. An analog signal was used, and the access technology was frequency division multiple access (FDMA, continuous wave). A nominal net forward power of 68 W was used, and the nominal power density at the center of the exposure flask was 860 W/m(2). The mean specific absorption rate in the exposure flask was 4.4 or 5.0 W/kg. Aliquots of diluted blood that were sham-exposed or exposed in vitro to an acute dose of 1.50 Gy of gamma radiation were used as negative or positive controls. Immediately after the exposures, the lymphocytes were stimulated with a mitogen, phytohemagglutinin, and cultured for 48 or 72 h to determine the extent of genetic damage, as assessed from the frequencies of chromosomal aberrations and micronuclei. The extent of alteration in the kinetics of cell proliferation was determined from the mitotic indices in 48-h cultures and from the incidence of binucleate cells in 72-h cultures. The data indicated no significant differences between RF-radiation- and sham-exposed lymphocytes with respect to mitotic indices, incidence of exchange aberrations, excess fragments, binucleate cells, and micronuclei. In contrast, the response of the lymphocytes exposed to gamma radiation was significantly different from both RF-radiation- and sham-exposed cells for all of these indices. Thus, under the experimental conditions tested, there is no evidence for the induction of chromosomal aberrations and micronuclei in human blood lymphocytes exposed in vitro for 24 h to 835.62 MHz RF radiation at SARs of 4.4 or 5.0 W/kg.

  5. Generation of tunable narrow-band surface-emitted terahertz radiation in periodically poled lithium niobate.

    Science.gov (United States)

    Weiss, C; Torosyan, G; Avetisyan, Y; Beigang, R

    2001-04-15

    Generation of tunable narrow-band terahertz (THz) radiation perpendicular to the surface of periodically poled lithium niobate by optical rectification of femtosecond pulses is reported. The generated THz radiation can be tuned by use of different poling periods and different observation angles, limited only by the available bandwidth of the pump pulse. Typical bandwidths were 50-100 GHz, depending on the collection angle and the number of periods involved.

  6. New Horizons in Enhancing the Proliferation and Differentiation of Neural Stem Cells Using Stimulatory Effects of the Short Time Exposure to Radiofrequency Radiation.

    Science.gov (United States)

    Eghlidospour, M; Mortazavi, S M J; Yousefi, F; Mortazavi, S A R

    2015-09-01

    Mobile phone use and wireless communication technology have grown explosively over the past decades. This rapid growth has caused widespread global concern about the potential detrimental effects of this technology on human health. Stem cells generate specialized cell types of the tissue in which they reside through normal differentiation pathways. Considering the undeniable importance of stem cells in modern medicine, numerous studies have been performed on the effects of ionizing and non-ionizing radiation on cellular processes such as: proliferation, differentiation, cell cycle and DNA repair processes. We have conducted extensive studies on beneficial (stimulatory) or detrimental biological effects of exposure to different sources of electromagnetic fields such as mobile phones, mobile phone base stations, mobile phone jammers, radar systems, magnetic resonance imaging (MRI) systems and dentistry cavitrons over the past years. In this article, recent studies on the biological effects of non-ionizing electromagnetic radiation in the range of radiofrequency (RF) on some important features of stem cells such as their proliferation and differentiation are reviewed. Studies reviewed in this paper indicate that the stimulatory or inhibitory effects of RF radiation on the proliferation and differentiation of stem cells depend on various factors such as the biological systems, experiment conditions, the frequency and intensity of RF and the duration of exposure.

  7. Monte Carlo simulation of radiative transfer in scattering, emitting, absorbing slab with gradient index

    International Nuclear Information System (INIS)

    Huang Yong; Liang Xingang; Xia Xinlin

    2005-01-01

    The Monte Carlo method is used to simulate the thermal emission of absorbing-emitting-scattering slab with gradient index. Three Monte Carlo ray-tracing strategies are considered. The first strategy is keeping the real distribution of the refractive index and to trace bundles in a curve route. The second strategy is discretizing the slab into sub-layers, each having constant refractive index. The bundle is traced in a straight route in each sub-layer and the reflection at the inner interface is taken into account. The third strategy is similar to the second one but only the total reflection at the inner interface is computed. Little difference is observed among the results of apparent thermal emission by these three different Monte Carlo ray tracing strategies. The results also show that the apparent hemispherical emissivity non-monotonously varies with increasing optical thickness of the slab with strong scattering gradient index. Many parameters can influence the apparent thermal emission greatly

  8. Reprint of 'Evaluation of Scattered Radiation Emitted From X-ray Security Scanners on Occupational Dose to Airport Personnel'

    Science.gov (United States)

    Dalah, Entesar; Fakhry, Angham; Mukhtar, Asma; Al Salti, Farah; Bader, May; Khouri, Sara; Al-Zahmi, Reem

    2017-11-01

    Based on security issues and regulations airports are provided with luggage cargo scanners. These scanners utilize ionizing radiation that in principle present health risks toward humans. The study aims to investigate the amount of backscatter produced by passenger luggage and cargo toward airport personnel who are located at different distances from the scanners. To approach our investigation a Thermo Electron Radeye-G probe was used to quantify the backscattered radiation measured in terms of dose-rate emitted from airport scanners, Measurements were taken at the entrance and exit positions of the X-ray tunnel at three different distances (0, 50, and 100 cm) for two different scanners; both scanners include shielding curtains that reduce scattered radiation. Correlation was demonstrated using the Pearson coefficient test. Measurements confirmed an inverse relationship between dose rate and distance. An estimated occupational accumulative dose of 0.88 mSv/y, and 2.04 mSv/y were obtained for personnel working in inspection of carry-on, and cargo, respectively. Findings confirm that the projected dose of security and engineering staff are being well within dose limits.

  9. Electromagnetic radiation emitted by a plasma produced in air by laser pulses with lambda = 10.6 μm

    International Nuclear Information System (INIS)

    Danilychev, V.A.; Zvorykin, V.D.; Kholin, I.V.; Chugunov, A.Y.

    1981-01-01

    The spectrum, brightness, and energy have been measured for the electromagnetic radiation emitted by a plasma produced in air near a solid surface by pulses from a high-power CO 2 laser. The air pressure was varied over the range p 0 = 0.1--760 torr, and the laser power density was varied over the range q = 5 x 10 6 --10 8 W/cm 2 . At p 0 > or approx. =2--5 torr the radiation properties of the plasma are determined by a laser-beam absorption wave which arises in the gas. The maximum brightness temperature, T/sub b/approx. =50 000 K (lambda = 400 +- 20 nm), is reached at p 0 = 25 torr. The emission spectrum is quite different from an equilibrium spectrum, consisting primarily of NII, OII, and NIII lines. The total energy radiation by the plasma in the wavelength interval 360--2600 nm into a solid angle of 4π sr reaches 2.3% of the laser pulse energy

  10. Palliative treatment with radiation-emitting metallic stents in unresectable Bismuth type III or IV hilar cholangiocarcinoma.

    Science.gov (United States)

    Lu, Jian; Guo, Jin-He; Zhu, Hai-Dong; Zhu, Guang-Yu; Wang, Yong; Zhang, Qi; Chen, Li; Wang, Chao; Pan, Tian-Fan; Teng, Gao-Jun

    2017-01-01

    The emerging data for stenting in combination with brachytherapy in unresectable hilar cholangiocarcinoma are encouraging. The aim of this study was to evaluate the efficacy and safety of radiation-emitting metallic stents (REMS) for unresectable Bismuth type III or IV hilar cholangiocarcinoma. Consecutive patients who underwent percutaneous placement with REMS or uncovered self-expandable metallic stent (SEMS) for unresectable Bismuth type III or IV hilar cholangiocarcinoma between September 2011 and April 2016 were identified into this retrospective study. Data on patient demographics and overall survival, functional success, stent patency and complications were collected at the authors' hospital. A total of 59 patients were included: 33 (55.9%) in the REMS group and 26 (44.1%) in the SEMS group. The median overall survival was 338 days in the REMS group and 141 days in the SEMS group (philar cholangiocarcinoma, and seems to prolong survival as well as patency of stent in these patients.

  11. Note: Real time optical sensing of alpha-radiation emitting radioactive aerosols based on solid state nuclear track detector

    International Nuclear Information System (INIS)

    Kulkarni, A.; Bak, M. S.; Ha, S.; Joshirao, P.; Manchanda, V.; Kim, T.

    2015-01-01

    A sensitive radioactive aerosols sensor has been designed and developed. Its design guidance is based on the need for a low operational cost and reliable measurements to provide daily aerosol monitoring. The exposure of diethylene-glycol bis (allylcarbonate) to radiation causes modification of its physico-chemical properties like surface roughness and reflectance. In the present study, optical sensor based on the reflectance measurement has been developed with an aim to monitor real time presence of alpha radioactive aerosols emitted from thorium nitrate hydrate. The results shows that the fabricated sensor can detect 0.0157 kBq to 0.1572 kBq of radio activity by radioactive aerosols generated from (Th(NO 3 ) 4 ⋅ 5H 2 O) at 0.1 ml/min flow rate. The proposed instrument will be helpful to monitor radioactive aerosols in/around a nuclear facility, building construction sites, mines, and granite polishing factories

  12. Note: Real time optical sensing of alpha-radiation emitting radioactive aerosols based on solid state nuclear track detector

    Science.gov (United States)

    Kulkarni, A.; Ha, S.; Joshirao, P.; Manchanda, V.; Bak, M. S.; Kim, T.

    2015-06-01

    A sensitive radioactive aerosols sensor has been designed and developed. Its design guidance is based on the need for a low operational cost and reliable measurements to provide daily aerosol monitoring. The exposure of diethylene-glycol bis (allylcarbonate) to radiation causes modification of its physico-chemical properties like surface roughness and reflectance. In the present study, optical sensor based on the reflectance measurement has been developed with an aim to monitor real time presence of alpha radioactive aerosols emitted from thorium nitrate hydrate. The results shows that the fabricated sensor can detect 0.0157 kBq to 0.1572 kBq of radio activity by radioactive aerosols generated from (Th(NO3)4 ṡ 5H2O) at 0.1 ml/min flow rate. The proposed instrument will be helpful to monitor radioactive aerosols in/around a nuclear facility, building construction sites, mines, and granite polishing factories.

  13. Note: Real time optical sensing of alpha-radiation emitting radioactive aerosols based on solid state nuclear track detector

    Energy Technology Data Exchange (ETDEWEB)

    Kulkarni, A.; Bak, M. S., E-mail: tkim@skku.edu, E-mail: moonsoo@skku.edu [School of Mechanical Engineering, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); Ha, S. [SKKU Advanced Institute of Nano Technology (SAINT), Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); Joshirao, P.; Manchanda, V. [Department of Energy Science, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); Kim, T., E-mail: tkim@skku.edu, E-mail: moonsoo@skku.edu [School of Mechanical Engineering, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); SKKU Advanced Institute of Nano Technology (SAINT), Sungkyunkwan University, Suwon 440-746 (Korea, Republic of)

    2015-06-15

    A sensitive radioactive aerosols sensor has been designed and developed. Its design guidance is based on the need for a low operational cost and reliable measurements to provide daily aerosol monitoring. The exposure of diethylene-glycol bis (allylcarbonate) to radiation causes modification of its physico-chemical properties like surface roughness and reflectance. In the present study, optical sensor based on the reflectance measurement has been developed with an aim to monitor real time presence of alpha radioactive aerosols emitted from thorium nitrate hydrate. The results shows that the fabricated sensor can detect 0.0157 kBq to 0.1572 kBq of radio activity by radioactive aerosols generated from (Th(NO{sub 3}){sub 4} ⋅ 5H{sub 2}O) at 0.1 ml/min flow rate. The proposed instrument will be helpful to monitor radioactive aerosols in/around a nuclear facility, building construction sites, mines, and granite polishing factories.

  14. Instrumentation measurement and testing complex for detection and identification of radioactive materials using the emitted radiation

    International Nuclear Information System (INIS)

    Samossadny, V.T.; Dmitrenko, V.V.; Kadlin, V.V.; Kolesnikov, S.V.; Ulin, S.E.; Grachev, V.M.; Vlasik, K.F.; Dedenko, G.L.; Novikov, D.V.; Uteshev, Z.M.

    2006-01-01

    Simultaneous measurement of neutron and gamma radiation is a very usefull method for effective nuclear materials identification and control. The gamma-ray-neutron complex described in the paper is based on two multi-layer 3 He neutrons detectors and two High Pressure Xenon gamma-ray spectrometers assembled in one unit. All these detectors were callibrated on neutron and gamma-ray sources. The main characteristics of the instrumentation , its testing results and gamma-ray and neutron radiation parameters, which have been measured are represented in the paper. The gamma-neutron sources and fissile materials reliable detection and identification capability was demonstrated

  15. Transmission of Mössbauer rays through ferromagnets in radio-frequency magnetic field

    International Nuclear Information System (INIS)

    Dzyublik, A. Ya.; Sadykov, E. K.; Petrov, G. I.; Arinin, V. V.; Vagizov, F. G.; Spivak, V. Yu.

    2013-01-01

    The transmission of Mössbauer radiation through a thick ferromagnetic crystal, exposed to a radio-frequency (rf) magnetic field, is studied. The quantum-mechanical dynamical scattering theory is developed, taking into account the periodical reversals of the magnetic field at the nuclei. The Mössbauer forward scattering (FS) spectra of the weak ferromagnet FeBO 3 placed into rf field are measured. It is found that the coherent gamma wave in the crystal absorbs or emits only couples of the rf photons. As a result, the FS spectra consist of equidistant lines spaced by twice the frequency of the rf field in contrast to the absorption spectra

  16. A Numerical Simulation for Prediction of Infrared Radiation Emitted from Plain Surfaces with Different Geometries

    Directory of Open Access Journals (Sweden)

    Vakilabadi K.A.

    2017-08-01

    Full Text Available In this paper, infrared radiation exiting plain surfaces with different geometries is numerically simulated. Surfaces under consideration are assumed to have steady uniform heat generation inside. Moreover, the boundaries of the surfaces are considered to be at the surroundings temperature. Infrared radiation is calculated based on the temperature profile determined for the surface. The temperature profile of the surface is determined assuming the two dimensional heat conduction equations to govern the problem. The physical domain is transformed into the appropriate computational domain and the governing equation is mapped into the suitable forms in the new coordinate system of variables. After that the temperature profile of the surface is computed, the infrared radiation distribution of the surface is evaluated based on the equations given in the manuscript. The temperature profile as well as the IR images are given in the results section. It is concluded that the maximum value of infrared radiation of the surface occurs at the center. Moreover, it is concluded that among surfaces with equal areas, the one having the largest perimeter has the least value of IR at its center.

  17. SiC detectors to monitor ionizing radiations emitted from nuclear events and plasmas

    Science.gov (United States)

    Torrisi, L.; Cannavò, A.

    2016-09-01

    Silicon Carbide (SiC) semiconductor detectors are increasingly employed in Nuclear Physics for their advantages with respect to traditional silicon (Si). Such detectors show an energy resolution, charge mobility, response velocity and detection efficiency similar to Si detectors. However, the higher band gap (3.26 eV), the lower leakage current (∼10 pA) maintained also at room temperature, the higher radiation hardness and the higher density with respect to Si represent some indisputable advantages characterizing such detectors. The devices can be employed at high temperatures, at high absorbed doses and in the case of high visible light intensities, for example, in plasma, for limited exposition times without damage. Generally SiC Schottky diodes are employed in reverse polarization with an active region depth of the order of 100 µm, purity below 1014 cm-3 and an active area lower than 1 cm2. Measurements in the regime of proportionality with the radiation energy released in the active region and measurements in time-of-flight configuration are employed for nuclear emission events produced at both low and high fluences. Alpha spectra demonstrated an energy resolution of about 1.3% at 5.8 MeV. Radiation emission from laser-generated plasma can be monitored in terms of detected photons, electrons and ions, using the laser pulse as a start signal and the radiation detection as a stop signal, enabling to measure the ion velocity by knowing the target-detector flight distance. SiC spectra acquired in the Messina University laboratories using radioactive ion sources and at the PALS laboratory facility in Prague (Czech Republic) are presented. A preliminary study of the use of SiC detectors, embedded in a water equivalent polymer, as a dosimeter is presented and discussed.

  18. INTERACTION OF LASER RADIATION WITH MATTER: Influence of a target on operation of a pulsed CO2 laser emitting microsecond pulses

    Science.gov (United States)

    Baranov, V. Yu; Dolgov, V. A.; Malyuta, D. D.; Mezhevov, V. S.; Semak, V. V.

    1987-12-01

    The profile of pulses emitted by a TEA CO2 laser with an unstable resonator changed as a result of interaction of laser radiation with the surface of a metal in the presence of a breakdown plasma. This influence of a target on laser operation and its possible applications in laser processing of materials are analyzed.

  19. Modeling and parameterization of photoelectrons emitted in condensed matter by linearly polarized synchrotron radiation

    Science.gov (United States)

    Jablonski, A.

    2018-01-01

    Growing availability of synchrotron facilities stimulates an interest in quantitative applications of hard X-ray photoemission spectroscopy (HAXPES) using linearly polarized radiation. An advantage of this approach is the possibility of continuous variation of radiation energy that makes it possible to control the sampling depth for a measurement. Quantitative applications are based on accurate and reliable theory relating the measured spectral features to needed characteristics of the surface region of solids. A major complication in the case of polarized radiation is an involved structure of the photoemission cross-section for hard X-rays. In the present work, details of the relevant formalism are described and algorithms implementing this formalism for different experimental configurations are proposed. The photoelectron signal intensity may be considerably affected by variation in the positioning of the polarization vector with respect to the surface plane. This information is critical for any quantitative application of HAXPES by polarized X-rays. Different quantitative applications based on photoelectrons with energies up to 10 keV are considered here: (i) determination of surface composition, (ii) estimation of sampling depth, and (iii) measurements of an overlayer thickness. Parameters facilitating these applications (mean escape depths, information depths, effective attenuation lengths) were calculated for a number of photoelectron lines in four elemental solids (Si, Cu, Ag and Au) in different experimental configurations and locations of the polarization vector. One of the considered configurations, with polarization vector located in a plane perpendicular to the surface, was recommended for quantitative applications of HAXPES. In this configurations, it was found that the considered parameters vary weakly in the range of photoelectron emission angles from normal emission to about 50° with respect to the surface normal. The averaged values of the mean

  20. WORKSHOPS: Radiofrequency superconductivity

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    In the continual push towards higher energy particle beams, superconducting radiofrequency techniques now play a vital role, highlighted in the fifth workshop on radiofrequency superconductivity, held at DESY from 19 - 24 August 1991

  1. WORKSHOPS: Radiofrequency superconductivity

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1992-01-15

    In the continual push towards higher energy particle beams, superconducting radiofrequency techniques now play a vital role, highlighted in the fifth workshop on radiofrequency superconductivity, held at DESY from 19 - 24 August 1991.

  2. Medicina array demonstrator: calibration and radiation pattern characterization using a UAV-mounted radio-frequency source

    Science.gov (United States)

    Pupillo, G.; Naldi, G.; Bianchi, G.; Mattana, A.; Monari, J.; Perini, F.; Poloni, M.; Schiaffino, M.; Bolli, P.; Lingua, A.; Aicardi, I.; Bendea, H.; Maschio, P.; Piras, M.; Virone, G.; Paonessa, F.; Farooqui, Z.; Tibaldi, A.; Addamo, G.; Peverini, O. A.; Tascone, R.; Wijnholds, S. J.

    2015-06-01

    One of the most challenging aspects of the new-generation Low-Frequency Aperture Array (LFAA) radio telescopes is instrument calibration. The operational LOw-Frequency ARray (LOFAR) instrument and the future LFAA element of the Square Kilometre Array (SKA) require advanced calibration techniques to reach the expected outstanding performance. In this framework, a small array, called Medicina Array Demonstrator (MAD), has been designed and installed in Italy to provide a test bench for antenna characterization and calibration techniques based on a flying artificial test source. A radio-frequency tone is transmitted through a dipole antenna mounted on a micro Unmanned Aerial Vehicle (UAV) (hexacopter) and received by each element of the array. A modern digital FPGA-based back-end is responsible for both data-acquisition and data-reduction. A simple amplitude and phase equalization algorithm is exploited for array calibration owing to the high stability and accuracy of the developed artificial test source. Both the measured embedded element patterns and calibrated array patterns are found to be in good agreement with the simulated data. The successful measurement campaign has demonstrated that a UAV-mounted test source provides a means to accurately validate and calibrate the full-polarized response of an antenna/array in operating conditions, including consequently effects like mutual coupling between the array elements and contribution of the environment to the antenna patterns. A similar system can therefore find a future application in the SKA-LFAA context.

  3. Measurement of radiofrequency fields

    International Nuclear Information System (INIS)

    Leonowich, J.A.

    1992-05-01

    We are literally surrounded by radiofrequency (RFR) and microwave radiation, from both natural and man-made sources. The identification and control of man-made sources of RFR has become a high priority of radiation safety professionals in recent years. For the purposes of this paper, we will consider RFR to cover the frequencies from 3 kHz to 300 MHz, and microwaves from 300 MHz to 300 GHz, and will use the term RFR interchangeably to describe both. Electromagnetic radiation and field below 3 kHz is considered Extremely Low Frequency (ELF) and will not be discussed in this paper. Unlike x- and gamma radiation, RFR is non-ionizing. The energy of any RFR photon is insufficient to produce ionizations in matter. The measurement and control of RFR hazards is therefore fundamentally different from ionizing radiation. The purpose of this paper is to acquaint the reader with the fundamental issues involved in measuring and safely using RFR fields. 23 refs

  4. Sensitivity to Antibiotics of Bacteria Exposed to Gamma Radiation Emitted from Hot Soils of the High Background Radiation Areas of Ramsar, Northern Iran.

    Science.gov (United States)

    Mortazavi, Seyed Mohammad Javad; Zarei, Samira; Taheri, Mohammad; Tajbakhsh, Saeed; Mortazavi, Seyed Alireza; Ranjbar, Sahar; Momeni, Fatemeh; Masoomi, Samaneh; Ansari, Leila; Movahedi, Mohammad Mehdi; Taeb, Shahram; Zarei, Sina; Haghani, Masood

    2017-04-01

    Over the past several years our laboratories have investigated different aspects of the challenging issue of the alterations in bacterial susceptibility to antibiotics induced by physical stresses. To explore the bacterial susceptibility to antibiotics in samples of Salmonella enterica subsp. enterica serovar Typhimurium ( S. typhimurium ), Staphylococcus aureus , and Klebsiella pneumoniae after exposure to gamma radiation emitted from the soil samples taken from the high background radiation areas of Ramsar, northern Iran. Standard Kirby-Bauer test, which evaluates the size of the zone of inhibition as an indicator of the susceptibility of different bacteria to antibiotics, was used in this study. The maximum alteration of the diameter of inhibition zone was found for K. pneumoniae when tested for ciprofloxacin. In this case, the mean diameter of no growth zone in non-irradiated control samples of K. pneumoniae was 20.3 (SD 0.6) mm; it was 14.7 (SD 0.6) mm in irradiated samples. On the other hand, the minimum changes in the diameter of inhibition zone were found for S. typhimurium and S. aureus when these bacteria were tested for nitrofurantoin and cephalexin, respectively. Gamma rays were capable of making significant alterations in bacterial susceptibility to antibiotics. It can be hypothesized that high levels of natural background radiation can induce adaptive phenomena that help microorganisms better cope with lethal effects of antibiotics.

  5. Sensitivity to Antibiotics of Bacteria Exposed to Gamma Radiation Emitted from Hot Soils of the High Background Radiation Areas of Ramsar, Northern Iran

    Directory of Open Access Journals (Sweden)

    Seyed Mohammad Javad Mortazavi

    2017-04-01

    Full Text Available Background: Over the past several years our laboratories have investigated different aspects of the challenging issue of the alterations in bacterial susceptibility to antibiotics induced by physical stresses. Objective: To explore the bacterial susceptibility to antibiotics in samples of Salmonella enterica subsp. enterica serovar Typhimurium (S. typhimurium, Staphylococcus aureus, and Klebsiella pneumoniae after exposure to gamma radiation emitted from the soil samples taken from the high background radiation areas of Ramsar, northern Iran. Methods: Standard Kirby-Bauer test, which evaluates the size of the zone of inhibition as an indicator of the susceptibility of different bacteria to antibiotics, was used in this study. Results: The maximum alteration of the diameter of inhibition zone was found for K. pneumoniae when tested for ciprofloxacin. In this case, the mean diameter of no growth zone in non-irradiated control samples of K. pneumoniae was 20.3 (SD 0.6 mm; it was 14.7 (SD 0.6 mm in irradiated samples. On the other hand, the minimum changes in the diameter of inhibition zone were found for S. typhimurium and S. aureus when these bacteria were tested for nitrofurantoin and cephalexin, respectively. Conclusion: Gamma rays were capable of making significant alterations in bacterial susceptibility to antibiotics. It can be hypothesized that high levels of natural background radiation can induce adaptive phenomena that help microorganisms better cope with lethal effects of antibiotics.

  6. Nanometer-scale elongation rate fluctuations in the Myriophyllum aquaticum (Parrot feather) stem were altered by radio-frequency electromagnetic radiation.

    Science.gov (United States)

    Senavirathna, Mudalige Don Hiranya Jayasanka; Asaeda, Takashi; Thilakarathne, Bodhipaksha Lalith Sanjaya; Kadono, Hirofumi

    2014-01-01

    The emission of radio-frequency electromagnetic radiation (EMR) by various wireless communication base stations has increased in recent years. While there is wide concern about the effects of EMR on humans and animals, the influence of EMR on plants is not well understood. In this study, we investigated the effect of EMR on the growth dynamics of Myriophyllum aquaticum (Parrot feather) by measuring the nanometric elongation rate fluctuation (NERF) using a statistical interferometry technique. Plants were exposed to 2 GHz EMR at a maximum of 1.42 Wm(-2) for 1 h. After continuous exposure to EMR, M. aquaticum plants exhibited a statistically significant 51 ± 16% reduction in NERF standard deviation. Temperature observations revealed that EMR exposure did not cause dielectric heating of the plants. Therefore, the reduced NERF was due to a non-thermal effect caused by EMR exposure. The alteration in NERF continued for at least 2.5 h after EMR exposure and no significant recovery was found in post-EMR NERF during the experimental period.

  7. Studying the synergistic damage effects induced by 1.8 GHz radiofrequency field radiation (RFR) with four chemical mutagens on human lymphocyte DNA using comet assay in vitro

    International Nuclear Information System (INIS)

    Wang Baohong; He Jiliang; Jin Lifen; Lu Deqiang; Zheng Wei; Lou Jianlin; Deng Hongping

    2005-01-01

    The aim of this investigation was to study the synergistic DNA damage effects in human lymphocytes induced by 1.8 GHz radiofrequency field radiation (RFR, SAR of 3 W/kg) with four chemical mutagens, i.e. mitomycin C (MMC, DNA crosslinker), bleomycin (BLM, radiomimetic agent), methyl methanesulfonate (MMS, alkylating agent), and 4-nitroquinoline-1-oxide (4NQO, UV-mimetic agent). The DNA damage of lymphocytes exposed to RFR and/or with chemical mutagens was detected at two incubation time (0 or 21 h) after treatment with comet assay in vitro. Three combinative exposure ways were used. Cells were exposed to RFR and chemical mutagens for 2 and 3 h, respectively. Tail length (TL) and tail moment (TM) were utilized as DNA damage indexes. The results showed no difference of DNA damage indexes between RFR group and control group at 0 and 21 h incubation after exposure (P > 0.05). There were significant difference of DNA damage indexes between MMC group and RFR + MMC co-exposure group at 0 and 21 h incubation after treatment (P 0.05). The experimental results indicated 1.8 GHz RFR (SAR, 3 W/kg) for 2 h did not induce the human lymphocyte DNA damage effects in vitro, but could enhance the human lymphocyte DNA damage effects induced by MMC and 4NQO. The synergistic DNA damage effects of 1.8 GHz RFR with BLM or MMS were not obvious

  8. Influence of 1.8-GHz (GSM) radiofrequency radiation (RFR) on DNA damage and repair induced by X-rays in human leukocytes in vitro.

    Science.gov (United States)

    Zhijian, Chen; Xiaoxue, Li; Yezhen, Lu; Deqiang, Lu; Shijie, Chen; Lifen, Jin; Jianlin, Lou; Jiliang, He

    2009-01-01

    In the present study, the in vitro comet assay was used to determine whether 1.8-GHz radiofrequency radiation (RFR) can influence DNA repair in human leukocytes exposed to X-rays. The specific energy absorption rate (SAR) of 2 W/kg (the current European safety limit) was applied. The leukocytes from four young healthy donors were intermittently exposed to RFR for 24 h (fields on for 5 min, fields off for 10 min), and then irradiated with X-rays at doses of 0.25, 0.5, 1.0 and 2.0 Gy. DNA damage to human leukocytes was detected using the comet assay at 0, 15, 45, 90, 150 and 240 min after exposure to X-rays. Using the comet assay, the percent of DNA in the tail (% tail DNA) served as the indicator of DNA damage; the DNA repair percentage (DRP) served as the indicator of the DNA repair speed. The results demonstrated that (1) the DNA repair speeds of human leukocytes after X-ray exposure exhibited individual differences among the four donors; (2) the intermittent exposures of 1.8-GHz RFR at the SAR of 2 W/kg for 24 h did not directly induce DNA damage or exhibit synergistic effects with X-rays on human leukocytes.

  9. Acoustic Radiation Force Impulse Elastography for Efficacy Evaluation after Hepatocellular Carcinoma Radiofrequency Ablation: A Comparative Study with Contrast-Enhanced Ultrasound

    Directory of Open Access Journals (Sweden)

    Xiaohong Xu

    2014-01-01

    Full Text Available Aim. To explore acoustic radiation force impulse (ARFI elastography in assessing residual tumors of hepatocellular carcinoma (HCC after radiofrequency ablation (RFA. Materials and Methods. There were 83 HCC lesions among 72 patients. All patients were examined with ARFI, contrast enhanced ultrasound (CEUS, and CT or MRI. Tumor brightness on virtual touch tissue imaging (VTI and shear wave velocity (SWV were assessed before and approximately one month after RFA. Results. There were 14 residual tumors after RFA. VTI showed that all the tumors were darker after RFA. VTI was not able to distinguish the ablated lesions and the residual tumors. 13 residual tumor lesions were detected by CEUS. All completely ablated nodules had SWV demonstration of x.xx., while with those residual nodules, 6 tumors had x.xx measurement and 8 tumors had measurable SWV. nine lesions with residual tumors occurred in cirrhosis subjects and 5 lesions with residual tumors occurred in fibrosis subjects; there was no residual tumor in the normal liver subjects. Conclusion. VTI technique cannot demonstrate residual tumor post RFA. While SWV measurement of less than x.xx is likely associated with residual tumors, measurement of less than x.xx cannot exclude residual tumors. Liver cirrhosis is associated with decreased chance of a complete ablation.

  10. Acoustic Radiation Force Impulse Elastography for Efficacy Evaluation after Hepatocellular Carcinoma Radiofrequency Ablation: A Comparative Study with Contrast-Enhanced Ultrasound

    Science.gov (United States)

    Xu, Xiaohong; Luo, Liangping; Chen, Jiexin; Wang, Jiexin; Zhou, Honglian; Li, Mingyi; Jin, Zhanqiang; Chen, Nianping; Miao, Huilai; Lin, Manzhou; Dai, Wei; Ahuja, Anil T.; Wang, Yi-Xiang J.

    2014-01-01

    Aim. To explore acoustic radiation force impulse (ARFI) elastography in assessing residual tumors of hepatocellular carcinoma (HCC) after radiofrequency ablation (RFA). Materials and Methods. There were 83 HCC lesions among 72 patients. All patients were examined with ARFI, contrast enhanced ultrasound (CEUS), and CT or MRI. Tumor brightness on virtual touch tissue imaging (VTI) and shear wave velocity (SWV) were assessed before and approximately one month after RFA. Results. There were 14 residual tumors after RFA. VTI showed that all the tumors were darker after RFA. VTI was not able to distinguish the ablated lesions and the residual tumors. 13 residual tumor lesions were detected by CEUS. All completely ablated nodules had SWV demonstration of x.xx., while with those residual nodules, 6 tumors had x.xx measurement and 8 tumors had measurable SWV. nine lesions with residual tumors occurred in cirrhosis subjects and 5 lesions with residual tumors occurred in fibrosis subjects; there was no residual tumor in the normal liver subjects. Conclusion. VTI technique cannot demonstrate residual tumor post RFA. While SWV measurement of less than x.xx is likely associated with residual tumors, measurement of less than x.xx cannot exclude residual tumors. Liver cirrhosis is associated with decreased chance of a complete ablation. PMID:24895624

  11. Radiation effects in light emitting diodes, laser diodes, photodiodes and optocouplers

    International Nuclear Information System (INIS)

    Lischka, H.; Henschel, H.; Koehn, O.; Lennartz, W.; Schmidt, H.U.

    1994-01-01

    A variety of commercially available LEDs, LDs, PDs, and optocouplers from two German manufacturers were irradiated at a flash X-ray source, a 60 Co gamma ray source, and a 14 MeV neutron generator. Light output and emission spectrum of the LEDs and LDs were measured before and after irradiation at the 60 Co source. With the PDs we measured the dark current and the photo current before and after 60 Co irradiation. Determination of the sensitivity against neutrons was made off-line. With PDs we measured the photo current induced by pulsed X-rays. The GaAs LED showed a maximum decrease of output power of 28 dB after a total gamma dose of 10 6 Gy and LDs a threshold current shift of 80% after neutron fluences of 4 - 10 14 cm -2 (1 MeV). Irradiations of PDs and APDs with 60 Co gammas up to a total dose of 10 6 Gy as well as irradiations with neutrons up to fluences of ≤ 4 - 10 14 cm -2 (1 MeV) led to significant changes of the device parameters. The main effect was a strong increase of the dark current. The consequence was a reduction of the minimum detectable light power. Optocouplers are very sensitive to ionizing radiation. Gammas as well as neutrons led to a decrease of the CTR and a change of the bandwidth up to a complete failure (after neutron irradiation). (author). 9 refs., 11 figs., 4 tabs

  12. Wideband analysis of railway catenary line radiation and new applications of its unintentional emitted signals

    Science.gov (United States)

    Heddebaut, Marc; Deniau, Virginie; Rioult, Jean

    2018-06-01

    Generally, in railway networks, dissipated energy—and its consequences in terms of noise, ballast attrition, electromagnetic interference, etc—is considered a nuisance generated by this means of transport. Therefore, most studies are carried out with the aim of reducing it. This paper takes the opposite view and considers the particular case of the irreducible electromagnetic interference generated along an electrified line, in order to propose new applications beneficial to railway operations. At a selected representative location, wideband (ranging from 10 kHz to 1 GHz) electromagnetic field measurements are performed successively during, and not during, high speed train passages. We deduce two potential applications of these unintentional signals. At low frequency, the first proposal considers energy harvesting using the received electromagnetic interference as the source. This received energy can be converted and used to DC feed low consumption sensors to be installed along the railway infrastructure. These sensors participate in monitoring infrastructure health and in making it more resilient to internal and external stresses. At higher frequencies, for the second proposal, radiation from the catenary line and train pantograph is specifically examined at a carefully selected sub-band. The results are also studied following a time–frequency analysis, to introduce a new nondestructive inspection method of the sliding contact between the catenary line and the train pantograph. Ultimately, this technique could offer a new means of monitoring the health of both the catenary line and the pantograph.

  13. High radiofrequency radiation at Stockholm Old Town: An exposimeter study including the Royal Castle, Supreme Court, three major squares and the Swedish Parliament

    Science.gov (United States)

    Hardell, Lennart; Carlberg, Michael; Koppel, Tarmo; Hedendahl, Lena

    2017-01-01

    Exposure to radiofrequency (RF) radiation was classified as a possible human carcinogen, Group 2B, by the International Agency for Research on Cancer at WHO in 2011. The exposure pattern is changing due to the rapid development of technology. Outdoor RF radiation level was measured during five tours in Stockholm Old Town in April, 2016 using the EME Spy 200 exposimeter with 20 predefined frequencies. The results were based on 10,437 samples in total. The mean level of the total RF radiation was 4,293 µW/m2 (0.4293 µW/cm2). The highest mean levels were obtained for global system for mobile communications (GSM) + universal mobile telecommunications system (UMTS) 900 downlink and long-term evolution (LTE) 2600 downlink (1,558 and 1,265 µW/m2, respectively). The town squares displayed highest total mean levels, with the example of Järntorget square with 24,277 µW/m2 (min 257, max 173,302 µW/m2). These results were in large contrast to areas with lowest total exposure, such as the Supreme Court, with a mean level of 404 µW/m2 (min 20.4, max 4,088 µW/m2). In addition, measurements in the streets surrounding the Royal Castle were lower than the total for the Old Town, with a mean of 756 µW/m2 (min 0.3, max 50,967 µW/m2). The BioInitiative 2012 Report defined the scientific benchmark for possible health risks as 30–60 µW/m2. Our results of outdoor RF radiation exposure at Stockholm Old Town are significantly above that level. The mean exposure level at Järntorget square was 405-fold higher than 60 µW/m2. Our results were below the reference level on 10,000,000 µW/m2 established by the International Commission on Non-Ionizing Radiation Protection (ICNIRP), which, however, are less credible, as they do not take non-thermal effects into consideration and are not based on sound scientific evaluation. Our highest measured mean level at Järntorget was 0.24% of the ICNIRP level. A number of studies have found adverse, non-thermal (no measurable temperature

  14. High radiofrequency radiation at Stockholm Old Town: An exposimeter study including the Royal Castle, Supreme Court, three major squares and the Swedish Parliament.

    Science.gov (United States)

    Hardell, Lennart; Carlberg, Michael; Koppel, Tarmo; Hedendahl, Lena

    2017-04-01

    Exposure to radiofrequency (RF) radiation was classified as a possible human carcinogen, Group 2B, by the International Agency for Research on Cancer at WHO in 2011. The exposure pattern is changing due to the rapid development of technology. Outdoor RF radiation level was measured during five tours in Stockholm Old Town in April, 2016 using the EME Spy 200 exposimeter with 20 predefined frequencies. The results were based on 10,437 samples in total. The mean level of the total RF radiation was 4,293 µW/m 2 (0.4293 µW/cm 2 ). The highest mean levels were obtained for global system for mobile communications (GSM) + universal mobile telecommunications system (UMTS) 900 downlink and long-term evolution (LTE) 2600 downlink (1,558 and 1,265 µW/m 2 , respectively). The town squares displayed highest total mean levels, with the example of Järntorget square with 24,277 µW/m 2 (min 257, max 173,302 µW/m 2 ). These results were in large contrast to areas with lowest total exposure, such as the Supreme Court, with a mean level of 404 µW/m 2 (min 20.4, max 4,088 µW/m 2 ). In addition, measurements in the streets surrounding the Royal Castle were lower than the total for the Old Town, with a mean of 756 µW/m 2 (min 0.3, max 50,967 µW/m 2 ). The BioInitiative 2012 Report defined the scientific benchmark for possible health risks as 30-60 µW/m 2 . Our results of outdoor RF radiation exposure at Stockholm Old Town are significantly above that level. The mean exposure level at Järntorget square was 405-fold higher than 60 µW/m 2 . Our results were below the reference level on 10,000,000 µW/m 2 established by the International Commission on Non-Ionizing Radiation Protection (ICNIRP), which, however, are less credible, as they do not take non-thermal effects into consideration and are not based on sound scientific evaluation. Our highest measured mean level at Järntorget was 0.24% of the ICNIRP level. A number of studies have found adverse, non-thermal (no measurable

  15. Alteration of glycine receptor immunoreactivity in the auditory brainstem of mice following three months of exposure to radiofrequency radiation at SAR 4.0 W/kg.

    Science.gov (United States)

    Maskey, Dhiraj; Kim, Hyung Gun; Suh, Myung-Whan; Roh, Gu Seob; Kim, Myeung Ju

    2014-08-01

    The increasing use of mobile communication has triggered an interest in its possible effects on the regulation of neurotransmitter signals. Due to the close proximity of mobile phones to hearing-related brain regions during usage, its use may lead to a decrease in the ability to segregate sounds, leading to serious auditory dysfunction caused by the prolonged exposure to radiofrequency (RF) radiation. The interplay among auditory processing, excitation and inhibitory molecule interactions plays a major role in auditory function. In particular, inhibitory molecules, such a glycine, are predominantly localized in the auditory brainstem. However, the effects of exposure to RF radiation on auditory function have not been reported to date. Thus, the aim of the present study was to investigate the effects of exposure to RF radiation on glycine receptor (GlyR) immunoreactivity (IR) in the auditory brainstem region at 835 MHz with a specific absorption rate of 4.0 W/kg for three months using free-floating immunohistochemistry. Compared with the sham control (SC) group, a significant loss of staining intensity of neuropils and cells in the different subdivisions of the auditory brainstem regions was observed in the mice exposed to RF radiation (E4 group). A decrease in the number of GlyR immunoreactive cells was also noted in the cochlear nuclear complex [anteroventral cochlear nucleus (AVCN), 31.09%; dorsal cochlear nucleus (DCN), 14.08%; posteroventral cochlear nucleus (PVCN), 32.79%] and the superior olivary complex (SOC) [lateral superior olivary nucleus (LSO), 36.85%; superior paraolivary nucleus (SPN), 24.33%, medial superior olivary nucleus (MSO), 23.23%; medial nucleus of the trapezoid body (MNTB), 10.15%] of the mice in the E4 group. Auditory brainstem response (ABR) analysis also revealed a significant threshold elevation of in the exposed (E4) group, which may be associated with auditory dysfunction. The present study suggests that the auditory brainstem region

  16. The effect of electromagnetic radiation emitted by display screens on cell oxygen metabolism – in vitro studies

    Science.gov (United States)

    Henrykowska, Gabriela A.; Pacholski, Krzysztof; Śmigielski, Janusz; Rutkowski, Maciej; Dziedziczak-Buczyńska, Maria; Buczyński, Andrzej

    2015-01-01

    Introduction Research studies carried out for decades have not solved the problem of the effect of electromagnetic radiation of various frequency and strength on the human organism. Due to this fact, we decided to investigate the changes taking place in human blood platelets under the effect of electromagnetic radiation (EMR) emitted by LCD monitors. Material and methods The changes of selected parameters of oxygen metabolism were measured, i.e. reactive oxygen species concentration, enzymatic activity of antioxidant defence proteins – superoxide dismutase (SOD-1) and catalase (CAT) – and malondialdehyde concentration (MDA). A suspension of human blood platelets was exposed to electromagnetic radiation of 1 kHz frequency and 150 V/m and 220 V/m intensity for 30 and 60 min. The level of changes of the selected parameters of oxidative stress was determined after the exposure and compared to the control samples (not exposed). Results The measurements revealed an increase of the concentration of reactive oxygen species. The largest increase of ROS concentration vs. the control sample was observed after exposure to EMF of 220 V/m intensity for 60 min (from x = 54.64 to x = 72.92). The measurement of MDA concentration demonstrated a statistically significant increase after 30-min exposure to an EMF of 220 V/m intensity in relation to the initial values (from x = 3.18 to x = 4.41). The enzymatic activity of SOD-1 decreased after exposure (the most prominent change was observed after 60-min and 220 V/m intensity from x = 3556.41 to x = 1084.83). The most significant change in activity of catalase was observed after 60 min and 220 v/m exposure (from x = 6.28 to x = 4.15). Conclusions The findings indicate that exposure to electromagnetic radiation of 1 kHz frequency and 150 V/m and 220 V/m intensity may cause adverse effects within blood platelets’ oxygen metabolism and thus may lead to physiological dysfunction of the organism. PMID:26788099

  17. Assessment of outdoor radiofrequency electromagnetic field exposure through hotspot localization using kriging-based sequential sampling.

    Science.gov (United States)

    Aerts, Sam; Deschrijver, Dirk; Verloock, Leen; Dhaene, Tom; Martens, Luc; Joseph, Wout

    2013-10-01

    In this study, a novel methodology is proposed to create heat maps that accurately pinpoint the outdoor locations with elevated exposure to radiofrequency electromagnetic fields (RF-EMF) in an extensive urban region (or, hotspots), and that would allow local authorities and epidemiologists to efficiently assess the locations and spectral composition of these hotspots, while at the same time developing a global picture of the exposure in the area. Moreover, no prior knowledge about the presence of radiofrequency radiation sources (e.g., base station parameters) is required. After building a surrogate model from the available data using kriging, the proposed method makes use of an iterative sampling strategy that selects new measurement locations at spots which are deemed to contain the most valuable information-inside hotspots or in search of them-based on the prediction uncertainty of the model. The method was tested and validated in an urban subarea of Ghent, Belgium with a size of approximately 1 km2. In total, 600 input and 50 validation measurements were performed using a broadband probe. Five hotspots were discovered and assessed, with maximum total electric-field strengths ranging from 1.3 to 3.1 V/m, satisfying the reference levels issued by the International Commission on Non-Ionizing Radiation Protection for exposure of the general public to RF-EMF. Spectrum analyzer measurements in these hotspots revealed five radiofrequency signals with a relevant contribution to the exposure. The radiofrequency radiation emitted by 900 MHz Global System for Mobile Communications (GSM) base stations was always dominant, with contributions ranging from 45% to 100%. Finally, validation of the subsequent surrogate models shows high prediction accuracy, with the final model featuring an average relative error of less than 2dB (factor 1.26 in electric-field strength), a correlation coefficient of 0.7, and a specificity of 0.96. Copyright © 2013 Elsevier Inc. All rights

  18. Origin of the low frequency radiation emitted by radiative polaritons excited by infrared radiation in planar La2O3 films.

    Science.gov (United States)

    Vincent-Johnson, Anita J; Schwab, Yosyp; Mann, Harkirat S; Francoeur, Mathieu; Hammonds, James S; Scarel, Giovanna

    2013-01-23

    Upon excitation in thin oxide films by infrared radiation, radiative polaritons are formed with complex angular frequency ω, according to the theory of Kliewer and Fuchs (1966 Phys. Rev. 150 573). We show that radiative polaritons leak radiation with frequency ω(i) to the space surrounding the oxide film. The frequency ω(i) is the imaginary part of ω. The effects of the presence of the radiation leaked out at frequency ω(i) are observed experimentally and numerically in the infrared spectra of La(2)O(3) films on silicon upon excitation by infrared radiation of the 0TH type radiative polariton. The frequency ω(i) is found in the microwave to far infrared region, and depends on the oxide film chemistry and thickness. The presented results might aid in the interpretation of fine structures in infrared and, possibly, optical spectra, and suggest the study of other similar potential sources of electromagnetic radiation in different physical scenarios.

  19. Development of Radiation-Resistant In-Water Wireless Transmission System Using Light Emitting Diodes and Photo Diodes

    Science.gov (United States)

    Takeuchi, T.; Shibata, H.; Otsuka, N.; Uehara, T.; Tsuchiya, K.; Shibagaki, T.; Komanome, H.

    2016-10-01

    Several kinds of commercially available light emitting diodes (LED) and photo diodes (PD) were irradiated with 60Co gamma ray up to 1 MGy for development of a radiation-resistant in-water wireless transmission system using visible light. The lens parts of the LEDs turned brown by the irradiation and their colors became dark with the absorbed dose. The total luminous fluxes decreased with the absorbed dose and the LED with shorter emission wavelength had the higher decrease rate. Meanwhile, the current-voltage characteristics hardly changed. These results indicate that the decreases of the total luminous flux of the LEDs were mainly caused not by the degradation of the semiconductor parts but by the coloring of the lens parts by the irradiation. On the other hand, the light sensitivities of the PDs decreased with the absorbed dose. The PDs with the window part which turned a darker color had the higher decrease rate. These results indicate that the decreases of light sensitivities of the PDs were also mainly caused by the coloring of the resin parts by the irradiation. If the wireless transmission is performed using the candidate LED and PD between 5 meters in water, using a few LEDs and PDs, the PD's output current generated by the emission light of the LED is estimated to be detectable even considering the effects of the absorption of the light in water and the increased dark current by the irradiation. Therefore, a radiation resistant in-water transmission system can be constructed using commercially available LEDs and PDs in principle.

  20. Efficient Computation of Coherent Synchrotron Radiation Taking into Account 6D Phase Space Distribution of Emitting Electrons

    International Nuclear Information System (INIS)

    Chubar, O.; Couprie, M.-E.

    2007-01-01

    CPU-efficient method for calculation of the frequency domain electric field of Coherent Synchrotron Radiation (CSR) taking into account 6D phase space distribution of electrons in a bunch is proposed. As an application example, calculation results of the CSR emitted by an electron bunch with small longitudinal and large transverse sizes are presented. Such situation can be realized in storage rings or ERLs by transverse deflection of the electron bunches in special crab-type RF cavities, i.e. using the technique proposed for the generation of femtosecond X-ray pulses (A. Zholents et. al., 1999). The computation, performed for the parameters of the SOLEIL storage ring, shows that if the transverse size of electron bunch is larger than the diffraction limit for single-electron SR at a given wavelength -- this affects the angular distribution of the CSR at this wavelength and reduces the coherent flux. Nevertheless, for transverse bunch dimensions up to several millimeters and a longitudinal bunch size smaller than hundred micrometers, the resulting CSR flux in the far infrared spectral range is still many orders of magnitude higher than the flux of incoherent SR, and therefore can be considered for practical use

  1. Comparison of the Effectiveness of Radiofrequency Ablation With Stereotactic Body Radiation Therapy in Inoperable Stage I Non-Small Cell Lung Cancer: A Systemic Review and Pooled Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Bi, Nan [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Department of Radiation Oncology, Cancer Hospital and Institute, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing (China); Shedden, Kerby [Department of Biostatistics, University of Michigan, Ann Arbor, Michigan (United States); Zheng, Xiangpeng [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Kong, Feng-Ming, E-mail: fskong@iupui.edu [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Department of Radiation Oncology, Indiana University, Indianapolis (United States)

    2016-08-01

    Purpose: To performed a systematic review and pooled analysis to compare clinical outcomes of stereotactic body radiation therapy (SBRT) and radiofrequency ablation (RFA) for the treatment of medically inoperable stage I non-small cell lung cancer. Methods and Materials: A comprehensive literature search for published trials from 2001 to 2012 was undertaken. Pooled analyses were performed to obtain overall survival (OS) and local tumor control rates (LCRs) and adverse events. Regression analysis was conducted considering each study's proportions of stage IA and age. Results: Thirty-one studies on SBRT (2767 patients) and 13 studies on RFA (328 patients) were eligible. The LCR (95% confidence interval) at 1, 2, 3, and 5 years for RFA was 77% (70%-85%), 48% (37%-58%), 55% (47%-62%), and 42% (30%-54%) respectively, which was significantly lower than that for SBRT: 97% (96%-98%), 92% (91%-94%), 88% (86%-90%), and 86% (85%-88%) (P<.001). These differences remained significant after correcting for stage IA and age (P<.001 at 1 year, 2 years, and 3 years; P=.04 at 5 years). The effect of RFA was not different from that of SBRT on OS (P>.05). The most frequent complication of RFA was pneumothorax, occurring in 31% of patients, whereas that for SBRT (grade ≥3) was radiation pneumonitis, occurring in 2% of patients. Conclusions: Compared with RFA, SBRT seems to have a higher LCR but similar OS. More studies with larger sample sizes are warranted to validate such findings.

  2. NEW Fe IX LINE IDENTIFICATIONS USING SOLAR AND HELIOSPHERIC OBSERVATORY/SOLAR ULTRAVIOLET MEASUREMENT OF EMITTED RADIATION AND HINODE/EIS JOINT OBSERVATIONS OF THE QUIET SUN

    International Nuclear Information System (INIS)

    Landi, E.; Young, P. R.

    2009-01-01

    In this work, we study joint observations of Hinode/EUV Imaging Spectrometer (EIS) and Solar and Heliospheric Observatory/Solar Ultraviolet Measurement of Emitted Radiation of Fe IX lines emitted by the same level of the high energy configuration 3s 2 3p 5 4p. The intensity ratios of these lines are dependent on atomic physics parameters only and not on the physical parameters of the emitting plasma, so that they are excellent tools to verify the relative intensity calibration of high-resolution spectrometers that work in the 170-200 A and 700-850 A wavelength ranges. We carry out extensive atomic physics calculations to improve the accuracy of the predicted intensity ratio, and compare the results with simultaneous EIS-SUMER observations of an off-disk quiet Sun region. We were able to identify two ultraviolet lines in the SUMER spectrum that are emitted by the same level that emits one bright line in the EIS wavelength range. Comparison between predicted and measured intensity ratios, wavelengths and energy separation of Fe IX levels confirms the identifications we make. Blending and calibration uncertainties are discussed. The results of this work are important for cross-calibrating EIS and SUMER, as well as future instrumentation.

  3. IEEE Committee on Man and Radiation--COMAR technical information statement radiofrequency safety and utility Smart Meters.

    Science.gov (United States)

    Bushberg, Jerrold T; Foster, Kenneth R; Hatfield, James B; Thansandote, Arthur; Tell, Richard A

    2015-03-01

    This Technical Information Statement describes Smart Meter technology as used with modern electric power metering systems and focuses on the radio frequency (RF) emissions associated with their operation relative to human RF exposure limits. Smart Meters typically employ low power (-1 W or less) transmitters that wirelessly send electric energy usage data to the utility company several times per day in the form of brief, pulsed emissions in the unlicensed frequency bands of 902-928 MHz and 2.4-2.48 GHz or on other nearby frequencies. Most Smart Meters operate as wireless mesh networks where each Smart Meter can communicate with other neighboring meters to relay data to a data collection point in the region. This communication process includes RF emissions from Smart Meters representing energy usage as well as the relaying of data from other meters and emissions associated with maintaining the meter's hierarchy within the wireless network. As a consequence, most Smart Meters emit RF pulses throughout the day, more at certain times and less at others. However, the duty cycle associated with all of these emissions is very small, typically less than 1%, and most of the time far less than 1%, meaning that most Smart Meters actually transmit RF fields for only a few minutes per day at most. The low peak power of Smart Meters and the very low duty cycles lead to the fact that accessible RF fields near Smart Meters are far below both U.S. and international RF safety limits whether judged on the basis of instantaneous peak power densities or time-averaged exposures. This conclusion holds for Smart Meters alone or installed in large banks of meters.

  4. Radiofrequency Ablation of Lung Tumors

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Radiofrequency Ablation (RFA) / Microwave Ablation (MWA) of Lung Tumors ... and Microwave Ablation of Lung Tumors? What are Radiofrequency and Microwave Ablation of Lung Tumors? Radiofrequency ablation, ...

  5. Effect of cell phone radiofrequency radiation on body temperature in rodents: Pilot studies of the National Toxicology Program's reverberation chamber exposure system.

    Science.gov (United States)

    Wyde, Michael E; Horn, Thomas L; Capstick, Myles H; Ladbury, John M; Koepke, Galen; Wilson, Perry F; Kissling, Grace E; Stout, Matthew D; Kuster, Niels; Melnick, Ronald L; Gauger, James; Bucher, John R; McCormick, David L

    2018-04-01

    Radiofrequency radiation (RFR) causes heating, which can lead to detrimental biological effects. To characterize the effects of RFR exposure on body temperature in relation to animal size and pregnancy, a series of short-term toxicity studies was conducted in a unique RFR exposure system. Young and old B6C3F1 mice and young, old, and pregnant Harlan Sprague-Dawley rats were exposed to Global System for Mobile Communication (GSM) or Code Division Multiple Access (CDMA) RFR (rats = 900 MHz, mice = 1,900 MHz) at specific absorption rates (SARs) up to 12 W/kg for approximately 9 h a day for 5 days. In general, fewer and less severe increases in body temperature were observed in young than in older rats. SAR-dependent increases in subcutaneous body temperatures were observed at exposures ≥6 W/kg in both modulations. Exposures of  ≥10 W/kg GSM or CDMA RFR induced excessive increases in body temperature, leading to mortality. There was also a significant increase in the number of resorptions in pregnant rats at 12 W/kg GSM RFR. In mice, only sporadic increases in body temperature were observed regardless of sex or age when exposed to GSM or CDMA RFR up to 12 W/kg. These results identified SARs at which measurable RFR-mediated thermal effects occur, and were used in the selection of exposures for subsequent toxicology and carcinogenicity studies. Bioelectromagnetics. 39:190-199, 2018. © 2018 The Authors. Bioelectromagnetics Published by Wiley Periodicals, Inc. © 2018 The Authors. Bioelectromagnetics Published by Wiley Periodicals, Inc.

  6. Klebsiella pneumonia, a Microorganism that Approves the Non-linear Responses to Antibiotics and Window Theory after Exposure to Wi-Fi 2.4 GHz Electromagnetic Radiofrequency Radiation

    Directory of Open Access Journals (Sweden)

    Taheri M.

    2015-09-01

    Full Text Available Background: Drug resistance is widely believed to be an increasingly serious threat to global public health. We have previously reported that short term exposure of microorganisms to diagnostic ultrasound waves could significantly alter their sensitivity to antibiotics. In our previous studies, Klebsiella pneumoniae showed major differences in the sensitivity to antibiotics in exposed and non-exposed samples. This study was aimed at investigating the alteration of antibiotic resistance of Klebsiella pneumonia, after exposure to Wi-Fi 2.4 GHz electromagnetic radiofrequency radiation. Materials and Methods: In this in vitro study, three replicate agar plates were used for each test. The antibiotic susceptibility test was carried out using disc diffusion method on Mueller Hinton agar plates and the inhibition zones in both control and exposed groups were measured. A common Wi-Fi router was used in this study as the radiofrequency exposure source. Irradiated samples were exposed to Wi-Fi radiofrequency radiation for 3, 4.5 and 8 hours. Results: Statistically significant variations of sensitivity to antibiotics were found for all studied antibiotics after 4.5 hours of RF exposure, compared to non-exposed bacteria. Interestingly, the mean diameters of the inhibition zones after 3 hours of exposure were less than those exposed for 4.5 hours. Following this rise in the sensitivity to antibiotics, a fall was observed in the bacteria exposed for 8 hours for all studied antibiotics. Conclusion: The findings of this study show a statistically significant rise in the sensitivity of Klebsiella pneumoniae to different antibiotics after 4.5 hours of exposure to 2.4 GHz Wi-Fi radiation, followed by a fall after 8 hours of exposure. These observations can be interpreted by the concept of non-linearity in the responses of Klebsiella pneumoniae to different antibiotics after exposure to electromagnetic radiofrequency radiation. As in this study a minimum level of

  7. The diagnosis of the gastric cancer using catheter-type semiconductor radiation detector. Comparison of diagnostic values of. beta. -emitting radionuclide label with. gamma. -emitting label

    Energy Technology Data Exchange (ETDEWEB)

    Sassa, R; Iwase, T [Asahi Life Foundation, Tokyo (Japan). Inst. for Adult Diseases; Sugita, T; Iio, M

    1975-06-01

    The diagnostic usefulness of /sup 32/P-phosphate for human gastric cancer, using a catheter-type semiconductor radiation detector (CASRAD) combined with gastrofiberscope technique, has already been reported by the authors. They have in addition used sup(99m)Tc-bleomycin, sup(99m)Tc-tetracycline in the diagnosis of experimental rabbit gastric cancer, too. In the present study, further refinement of the technique for the ..beta..-ray labeled substance (/sup 32/P-phosphate) for detection of the gastric cancer was compared with that of ..gamma..-ray labeled substance (sup(99m)Tc-tetracycline). A more correct diagnosis of the gastric cancer by in vivo measurement of beta activity could be obtained, when the collimater, made of stainless steel, was attached to the top of the detector. In this way contribution to the count from the adjacent tissues or organs could be eliminated. They were unable to produce an effective and useful collimater for ..gamma..-ray labeled substance which could to be used safely in vivo. Because of the unsatisfactory collimater, radioactivities of the adjacent organs caused on increase in the radioactivity of the background. Therefore inspite of the recent introduction of various sup(99m)Tc-tumor agents, these labels were not applicable to the CASRAD method. For such a small detector system, ..beta..-labels, represented by /sup 32/P-phosphate, was still prefererable to ..gamma..-labels.

  8. Potential health risks due to telecommunications radiofrequency ...

    African Journals Online (AJOL)

    Background: The global system mobile telecommunications system (GSM) which was recently introduced in Nigeria is now being used by over 40 million people in Nigeria. The use of GSM is accompanied with exposure of the users to radiofrequency radiation (RFR), which if significant, may produce health hazards. This is ...

  9. Discrete curved ray-tracing method for radiative transfer in an absorbing-emitting semitransparent slab with variable spatial refractive index

    International Nuclear Information System (INIS)

    Liu, L.H.

    2004-01-01

    A discrete curved ray-tracing method is developed to analyze the radiative transfer in one-dimensional absorbing-emitting semitransparent slab with variable spatial refractive index. The curved ray trajectory is locally treated as straight line and the complicated and time-consuming computation of ray trajectory is cut down. A problem of radiative equilibrium with linear variable spatial refractive index is taken as an example to examine the accuracy of the proposed method. The temperature distributions are determined by the proposed method and compared with the data in references, which are obtained by other different methods. The results show that the discrete curved ray-tracing method has a good accuracy in solving the radiative transfer in one-dimensional semitransparent slab with variable spatial refractive index

  10. Effect of Mobile Phone Radiofrequency Electromagnetic Fields on ...

    African Journals Online (AJOL)

    Summary: Since cell phones emit radiofrequency electromagnetic fields (EMFs), this study tested the hypothesis that cell phones placed near the heart may interfere with the electrical rhythm of the heart or affect the blood pressure. Following informed consent, eighteen randomly selected apparently healthy male volunteers ...

  11. An explanation of efficiency droop in InGaN-based light emitting diodes: saturated radiative recombination rate at randomly distributed In-rich active areas

    International Nuclear Information System (INIS)

    Shim, Jong-In; Kim, Hyun-Sung; Shin, Dong-Soo; Yoo, Han-Youl

    2011-01-01

    We present a comprehensive model of the dependence of the internal quantum efficiency (IQE) on both the temperature and the carrier density in InGaN-based blue and green light emitting diodes (LEDs). In our model, carriers are dominantly located and recombine both radiatively and nonradiatively inside randomly distributed In-rich areas of the InGaN quantum wells (QWs). In those areas, the carrier density is very high even at a small current density. We propose that the saturated radiative recombination rate is a primary factor determining the IQE droop of InGaN based LEDs. In typical InGaN-based QWs, it is common for the total carrier recombination rate to be smaller than the carrier injection rate even at a small current density. This is mostly attributable to the saturation of the radiative recombination rate. The saturation of the radiative recombination rate increases carrier density in InGaN QWs, enlarges nonradiative carrier losses, and eventually gives rise to the large IQE droop with increasing current. We show how the radiative recombination rate saturates and the radiative recombination rate has influence on the IQE droop in InGaN-based QW LEDs.

  12. Radiofrequency ablation in dermatology

    Directory of Open Access Journals (Sweden)

    Sachdeva Silonie

    2007-01-01

    Full Text Available Radiofreqeuency ablation is a versatile dermatosurgical procedure used for surgical management of skin lesions by using various forms of alternating current at an ultra high frequency. The major modalities in radiofrequency are electrosection, electrocoagulation, electrodessication and fulguration. The use of radiofrequency ablation in dermatosurgical practice has gained importance in recent years as it can be used to treat most of the skin lesions with ease in less time with clean surgical field due to adequate hemostasis and with minimal side effects and complications. This article focuses on the major tissue effects and factors influencing radiofrequency ablation and its application for various dermatological conditions.

  13. Impact of electromagnetic radiation emitted by monitors on changes in the cellular membrane structure and protective antioxidant effect of vitamin A - In vitro study.

    Science.gov (United States)

    Lewicka, Małgorzata; Henrykowska, Gabriela; Zawadzka, Magdalena; Rutkowski, Maciej; Pacholski, Krzysztof; Buczyński, Andrzej

    2017-07-14

    The increasing number of devices emitting electromagnetic radiation (EMR) in people's everyday life attracted the attention of researchers because of possible adverse effects of this factor on living organisms. One of the EMR effect may be peroxidation of lipid membranes formed as a result of free radical process. The article presents the results of in vitro studies aimed at identifying changes in malondialdehyde (MDA) concentration - a marker of lipid peroxidation and antioxidant role of vitamin A during the exposure of blood platelets to electromagnetic radiation generated by liquid-crystal-display (LCD) monitors. Electromagnetic radiation emitted by LCD monitors is characterized by parameters: 1 kHz frequency and 220 V/m intensity (15 cm from display screen). The time of exposure was 30 and 60 min. The study was conducted on porcine blood platelets. The samples were divided into 6 groups: unexposed to radiation, unexposed + vitamin A, exposed for 30 min, exposed for 30 min + vitamin A, exposed for 60 min, exposed for 60 min + vitamin A. The MDA concentration in blood platelets increases significantly as compared to control values after 60 min of exposure to EMR. A significant decrease in MDA concentration after the addition of vitamin A was noticed. In the blood samples exposed to EMR for 30 and 60 min the MDA concentration was significantly increased by addition of vitamin A. The results show the possibly negative effect of electromagnetic radiation on the cellular membrane structure manifested by changes in malondialdehyde concentration and indicate a possible protective role of vitamin A in this process. Int J Occup Med Environ Health 2017;30(5):695-703. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  14. Diminution of acute radiation reaction of mouse skin with low-intensity infrared laser/red diodes-emitted light

    International Nuclear Information System (INIS)

    Meshcherikova, V.V.; Klimakov, B.D.; Goldobenko, G.V.; Vajnson, A.A.

    2000-01-01

    Efficiency of the application of different regimes of laser treatment of radiation-induced skin reactions in mice feet is compared. Posterior limb feet of mice were exposed to acute X radiation at 30-36 Gy dose or fractionated radiation at 45 Gy dose. In the day of primary irradiation or different time later the feet were treated using magnetic infrared laser therapeutic MILTA-01 apparatus. Magnetic and light components of the MILTA-01 apparatus reduce the effect of radiation on mice skin corresponding two time decrease in X-radiation dose [ru

  15. RADIOFREQUENCY SUPERCONDUCTIVITY: Workshop

    International Nuclear Information System (INIS)

    Lengeler, Herbert

    1989-01-01

    Superconducting radiofrequency is already playing an important role in the beam acceleration system for the TRISTAN electron-positron collider at the Japanese KEK Laboratory and new such systems are being prepared for other major machines. Thus the fourth Workshop on Radiofrequency Superconductivity, organized by KEK under the chairmanship of local specialist Yuzo Kojima and held just before the International Conference on High Energy Accelerators, had much progress to review and even more to look forward to

  16. Development of computational pregnant female and fetus models and assessment of radiation dose from positron-emitting tracers

    DEFF Research Database (Denmark)

    Xie, Tianwu; Zaidi, H.

    2016-01-01

    /fetus presents a high sensitivity to ionizing radiation. Therefore, estimation of the radiation dose delivered to the embryo/fetus and pregnant patients from PET examinations to assess potential radiation risks is highly praised. Methods: We constructed eight embryo/fetus models at various gestation periods......Purpose: Molecular imaging using PET and hybrid (PET/CT and PET/MR) modalities nowadays plays a pivotal role in the clinical setting for diagnosis and staging, treatment response monitoring, and radiation therapy treatment planning of a wide range of oncologic malignancies. The developing embryo...

  17. Childhood leukemia in relation to radiofrequency electromagnetic fields emitted from television and radio broadcast transmitters. Results of a case-control study; Leukaemien im Kindesalter und elektromagnetische Felder in der Umgebung von Rundfunkstationen. Ergebnisse einer Fall-Kontroll-Studie

    Energy Technology Data Exchange (ETDEWEB)

    Schmiedel, Sven [Danish Cancer Society, Copenhagen (Denmark). Inst. of Cancer Epidemiology; Universitaetsmedizin Mainz Univ. (DE). Inst. fuer Medizinische Biometrie, Epidemiologie und Informatik (IMBEI); Merzenich, Hiltrud; Bennack, Sabrina; Blettner, Maria [Universitaetsmedizin Mainz Univ. (DE). Inst. fuer Medizinische Biometrie, Epidemiologie und Informatik (IMBEI); Brueggemeyer, Hauke [Niedersaechsischer Landesbetrieb fuer Wasserwirtschaft, Kuesten- und Naturschutz, Hildesheim (Germany). AB35 - Strahlenschutz in Niedersachsen; Philipp, Johannes [Suedwestrundfunk, Stuttgart (Germany). Abt. Frequenz- und Versorgungsplanung; Schuetz, Joachim [Danish Cancer Society, Copenhagen (Denmark). Inst. of Cancer Epidemiology

    2009-07-01

    The causes of childhood leukemia are poorly understood. Radio frequency electromagnetic fields (RF-EMF) emitted from broadcast stations are possible risk factors. A case-control study was conducted in West Germany on RF-EMF and childhood leukemia. The study region consisted of municipalities near 24 radio and television transmitters. Cases (aged 0-14 years, diagnosis 1984-2003) were registered at the German childhood cancer registry. Three age-, gender- and transmitter areamatched controls per case were drawn randomly from population registries. The analysis included 1,959 cases and 5,848 controls. The RF-EMF exposure was calculated with a field strength prediction program. In the statistical analysis conditional logistic regression was used. Considering total RF-EMF, the odds ratio for leukemia was 0.86 (95% confidence interval 0.67-1.11) comparing upper ({>=}95%) and lower (<90%) quantile for the RF-EMF distribution. No association between RF-EMF exposure and leukemia was observed for the time periods before and after the introduction of mobile telecommunication. There was no increased risk among children living in the 2 km vicinity of the transmitters. The study provides no evidence for an association between RF-EMF and childhood leukemia. (orig.)

  18. Monochromic radiation through light-emitting diode (LED positively augments in vitro shoot regeneration in Orchid (Dendrobium sonia

    Directory of Open Access Journals (Sweden)

    Vandita Billore

    2017-07-01

    Full Text Available Monochromatic lights emitted by light-emitting diodes (LEDs have generated great interest for efficient and controlled growth in vitro, especially of plants which are endangered or require specific intensity and wavelength of light. In the present study, we have evaluated the effect of monochromatic LEDs on in vitro morphogenesis: growth, proliferation of shoot cultures, and rooting of Dendrobium sonia. Different light sources viz. white LEDs (W, blue LEDs (B, yellow LEDs (Y and red LEDs (R were tested under photoperiod of 16 h of exposure and 8 h of dark. The frequency of morphogenesis depended on the wavelength of the applied monochromatic light. Higher wavelength monochromatic light (yellow light was observed to induce higher shoot proliferation (98%, early PLB (protocorm-like bodies formation, differentiation into green buds and shoot initiation as compared to red, blue and white light treatments. Yellow light also yielded higher number of shoots per explants (29 shoots/explant than red, blue and white light treatments. The results suggest that the monochromatic light sources stimulate morphogenic effects on in vitro culture of Dendrobium sonia, and that yellow light treatment can be used to enhance the efficiency of micropropagation.

  19. Determination of the exposure speed of radiation emitted by the linear accelerator, using the code MCNP5 to evaluate the radiotherapy room shields of ABC Hospital

    International Nuclear Information System (INIS)

    Corral B, J. R.

    2015-01-01

    Humans should avoid exposure to radiation, because the consequences are harmful to health. Although there are different emission sources of radiation, generated by medical devices they are usually of great interest, since people who attend hospitals are exposed in one way or another to ionizing radiation. Therefore, is important to conduct studies on radioactive levels that are generated in hospitals, as a result of the use of medical equipment. To determine levels of exposure speed of a radioactive facility there are different methods, including the radiation detector and computational method. This thesis uses the computational method. With the program MCNP5 was determined the speed of the radiation exposure in the radiotherapy room of Cancer Center of ABC Hospital in Mexico City. In the application of computational method, first the thicknesses of the shields were calculated, using variables as: 1) distance from the shield to the source; 2) desired weekly equivalent dose; 3) weekly total dose equivalent emitted by the equipment; 4) occupation and use factors. Once obtained thicknesses, we proceeded to model the bunker using the mentioned program. The program uses the Monte Carlo code to probabilistic ally determine the phenomena of interaction of radiation with the shield, which will be held during the X-ray emission from the linear accelerator. The results of computational analysis were compared with those obtained experimentally with the detection method, for which was required the use of a Geiger-Muller counter and the linear accelerator was programmed with an energy of 19 MV with 500 units monitor positioning the detector in the corresponding boundary. (Author)

  20. Increased Microleakage of Amalgam Restorations after Exposure to 2.4 Ghz Radiofrequency Electromagnetic Fields from Common Wi-Fi Routers

    Directory of Open Access Journals (Sweden)

    Mortazavi SMJ

    2017-09-01

    Full Text Available Statement of Problem: Previous studies have shown that exposure of dental amalgam fillings to MRI and mobile phones can increase microleakage of amalgam restorations. Objectives: The aim of this study was to evaluate the effects of exposure to radiofrequency radiation emitted from indoor Wi-Fi access devices on microleakage of amalgam restorations. Materials and Methods: Standard class V cavities were prepared on the buccal surfaces of 69 extracted human premolar teeth. The samples were divided into two exposure groups and one non-exposed control group of 23 teeth each. The specimens in the experimental groups were exposed to a radiofrequency (RF radiation emitted from a commercial 2.4 GHz Wi Fi router. The distance between the Wi-Fi router and samples was 30 cm and the router was exchanging data with a laptop computer that was placed 20 m away from the router. Teeth samples in the first exposure group (group A were exposed to RF for 3 days while the second exposure group (group B was exposed for 6 days. Then the teeth were sectioned and scored for microleakage under a stereomicroscope. Results: The score of microleakage was significantly higher in the exposure group A compared to that of the control group. However, the score of microleakage was not significantly different between the exposure group B and control group. Furthermore, the scores of microleakage was signifi-cantly higher in the exposure group A than that of the exposure group B. Conclusions: Exposure of patients with amalgam restorations to radiofre-quency waves emitted from commercial Wi-Fi routers can lead to in-creased microleakage of amalgam restorations.

  1. Mössbauer forward scattering spectra of ferromagnets in radio-frequency magnetic field

    Directory of Open Access Journals (Sweden)

    A. Ya. Dzyublik

    2012-03-01

    Full Text Available The transmission of Mössbauer radiation through a thick ferromagnetic crystal, subjected to the radio-frequency (rf magnetic field, is studied. A quantum-mechanical dynamical scattering theory is developed, taking into account both the periodical reversals of the magnetic field at the nuclei and their coherent vibrations. The Mössbauer forward scattering (FS spectra of the weak ferromagnet FeBO3 exposed to the rf field are measured. It is discovered that the coherent gamma wave in the crystal, interacting with Mössbauer nuclei, absorbs or emits only couples of the rf photons. As a result, the FS spectra consist of equidistant lines spaced by twice the frequency of the rf field in contrast to the absorption spectra. Our experimental data and calculations well agree if we assume that the hyperfine field at the nuclei in FeBO3 periodically reverses and there are no coherent vibrations.

  2. Electron Microscopy Study of Stainless Steel Radiation Damage Due to Long-Term Irradation by Alpha Particles Emitted From Plutonium

    Energy Technology Data Exchange (ETDEWEB)

    Unlu, Kenan [Univ. of Texas, Austin, TX (United States); Rios-Martinez, Carlos [Univ. of Texas, Austin, TX (United States); Saglam, Mehmet [Univ. of Texas, Austin, TX (United States); Hart, Ron R. [Texas A & M Univ., College Station, TX (United States); Shipp, John D. [Texas A & M Univ., College Station, TX (United States); Rennie, John [Texas A & M Univ., College Station, TX (United States)

    1998-04-16

    Radiation damage and associated surface and microstructural changes produced in stainless steel encapsulation by high-fluence alpha particle irradiations from weapons-grade plutonium of 316-stainless steel are being investigated.

  3. Simple method for routine check of the constancy of radiation quality of bremsstrahlung emitted by therapeutic particle accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Rassow, J; Eipper, H H; Krause, K [Essen Univ. (Gesamthochschule) (Germany, F.R.). Abt. fuer Klinische Strahlenphysik; Staedtisches Krankenhaus Koeln-Merheim (Germany, F.R.). Roentgeninstitut und Strahlenklinik)

    1977-05-01

    The constancy of the radiation quality of therapeutically employed particle accelerators has to be checked at weekly intervals. Any change in radiation quality may have considerable therapeutic effects owing to its influence on dose distribution. It is recommended that measurements be made instead of, or in addition to, the axial reference-point measurement at 5 and 15 cm depth in the phantom, at 5 cm depth in the beam axis and at a reference-point about 1 cm within the geometric edge of the field, for checking the constancy of the radiation quality of bremsstrahlung. Only then, if routine checks carried out for the axial and the lateral reference-point dose ratios do not show any deviations greater than e.g. +-2 %, radiation quality is deemed to have remained sufficiently constant for radiotherapeutical applications.

  4. Interaction between the radiative flux emitted by a corium melt and aerosols from corium/concrete interaction

    Energy Technology Data Exchange (ETDEWEB)

    Zabiego, M.; Cognet, G. [CEA-DRN/DER/SERA - CE Cadarache, Saint-Paul-Lez-Durance (France); Henderson, D. [Univ. of Wisconsin, Madison, WI (United States)

    1995-09-01

    In this paper we present a one-dimensional numerical model that deals with radiative transfer in a medium where aerosols are present. This model is written with the aim of performing radiative transfer calculations in the framework of severe Pressurized Water Reactor accidents, especially during the last stage of such an accident Molten Core Concrete Interaction (MCCI) when aerosols are very numerous. We explain the theoretical basis of our model, writing the general radiative transfer equation, knowing that aerosol droplets participate in radiation transport. We then simplify this equation for a one-dimensional medium and we propose to solve it using the spherical harmonics approximation. This gives us the radiative intensity and we can then deduce the radiative flux. Aerosol optical properties (extinction and scattering coefficients) are also required in such a calculation. They are determined using Rayleigh or Mie theory, depending, depending on the aerosol size. In order to provide an example of results one can expect from such a calculation, we applied our model to a test problem with given aerosol size and concentration distributions. Our example does not model any experiment explicitly but the physical conditions used are very close to the L4 test from the Advanced Containment Experiment (ACE) program.

  5. Radiofrequency ablation of osteoid osteoma

    NARCIS (Netherlands)

    Vanderschueren, Geert Maria Joris Michael

    2009-01-01

    The main purpose of this thesis was to evaluate the effectiveness and safety of CT-guided radiofrequency ablation for the treatment of spinal and non-spinal osteoid osteomas. Furthermore, the technical requirements needed for safe radiofrequency ablation and the clinical outcome after radiofrequency

  6. Automatic control by natural gamma radiation emitted by coal; Control Automatico mediante Radiometria Gamma Natural de la Cenizas de los Carbones

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    Due to the characteristics of its coal and orebody, Monsacro shaft was chosen to host the test. The ash percentage of the different coal seams was carried out by two different methods: Traditional analysis in laboratory. Analysis by means of natural gamma radiation emitted by coal. The following conclusions were obtained after the test: Neither during the mounting nor during the test, a problem was encountered in the working of the radioactive methods. The absolute error between the two methods was minimum. The radioactive analysis is total (this means that the whole coal is analysed) and it is carried out in short period of time. The traditional one is just partial, and could take a few hours to accomplish it. The radioactive one is done in the wagon or in the belt conveyor directly, meanwhile the traditional one needs sample takers permanently. The investment cost of the radioactivity method is amortized within two years. (Author)

  7. Assessment of outdoor radiofrequency electromagnetic field exposure through hotspot localization using kriging-based sequential sampling

    Energy Technology Data Exchange (ETDEWEB)

    Aerts, Sam, E-mail: sam.aerts@intec.ugent.be; Deschrijver, Dirk; Verloock, Leen; Dhaene, Tom; Martens, Luc; Joseph, Wout

    2013-10-15

    In this study, a novel methodology is proposed to create heat maps that accurately pinpoint the outdoor locations with elevated exposure to radiofrequency electromagnetic fields (RF-EMF) in an extensive urban region (or, hotspots), and that would allow local authorities and epidemiologists to efficiently assess the locations and spectral composition of these hotspots, while at the same time developing a global picture of the exposure in the area. Moreover, no prior knowledge about the presence of radiofrequency radiation sources (e.g., base station parameters) is required. After building a surrogate model from the available data using kriging, the proposed method makes use of an iterative sampling strategy that selects new measurement locations at spots which are deemed to contain the most valuable information—inside hotspots or in search of them—based on the prediction uncertainty of the model. The method was tested and validated in an urban subarea of Ghent, Belgium with a size of approximately 1 km{sup 2}. In total, 600 input and 50 validation measurements were performed using a broadband probe. Five hotspots were discovered and assessed, with maximum total electric-field strengths ranging from 1.3 to 3.1 V/m, satisfying the reference levels issued by the International Commission on Non-Ionizing Radiation Protection for exposure of the general public to RF-EMF. Spectrum analyzer measurements in these hotspots revealed five radiofrequency signals with a relevant contribution to the exposure. The radiofrequency radiation emitted by 900 MHz Global System for Mobile Communications (GSM) base stations was always dominant, with contributions ranging from 45% to 100%. Finally, validation of the subsequent surrogate models shows high prediction accuracy, with the final model featuring an average relative error of less than 2 dB (factor 1.26 in electric-field strength), a correlation coefficient of 0.7, and a specificity of 0.96. -- Highlights: • We present an

  8. Assessment of outdoor radiofrequency electromagnetic field exposure through hotspot localization using kriging-based sequential sampling

    International Nuclear Information System (INIS)

    Aerts, Sam; Deschrijver, Dirk; Verloock, Leen; Dhaene, Tom; Martens, Luc; Joseph, Wout

    2013-01-01

    In this study, a novel methodology is proposed to create heat maps that accurately pinpoint the outdoor locations with elevated exposure to radiofrequency electromagnetic fields (RF-EMF) in an extensive urban region (or, hotspots), and that would allow local authorities and epidemiologists to efficiently assess the locations and spectral composition of these hotspots, while at the same time developing a global picture of the exposure in the area. Moreover, no prior knowledge about the presence of radiofrequency radiation sources (e.g., base station parameters) is required. After building a surrogate model from the available data using kriging, the proposed method makes use of an iterative sampling strategy that selects new measurement locations at spots which are deemed to contain the most valuable information—inside hotspots or in search of them—based on the prediction uncertainty of the model. The method was tested and validated in an urban subarea of Ghent, Belgium with a size of approximately 1 km 2 . In total, 600 input and 50 validation measurements were performed using a broadband probe. Five hotspots were discovered and assessed, with maximum total electric-field strengths ranging from 1.3 to 3.1 V/m, satisfying the reference levels issued by the International Commission on Non-Ionizing Radiation Protection for exposure of the general public to RF-EMF. Spectrum analyzer measurements in these hotspots revealed five radiofrequency signals with a relevant contribution to the exposure. The radiofrequency radiation emitted by 900 MHz Global System for Mobile Communications (GSM) base stations was always dominant, with contributions ranging from 45% to 100%. Finally, validation of the subsequent surrogate models shows high prediction accuracy, with the final model featuring an average relative error of less than 2 dB (factor 1.26 in electric-field strength), a correlation coefficient of 0.7, and a specificity of 0.96. -- Highlights: • We present an

  9. Cytogenetic Damages Induced by Chronic Exposure to Microwave Non-Ionizing Radiofrequency Fields

    Directory of Open Access Journals (Sweden)

    Boris Đinđić

    2013-12-01

    Full Text Available Non-ionizing radiation has a significant and positive impact on modern society through a number of uses. There is increasing public concern regarding the health risks of radio-frequency (RF radiation, particularly that produced by mobile phones. Concern regarding the potential risks of exposure to EMFs has led to many epidemiological investigations, but the effects of EMF exposure on human and other mammalian cells are still unclear. One of the most frequently asked questions about the effects of microwave radiation on biological systems is whether they produce genotoxic effects and could be there a possible link with oncogenic processes. It is most difficult to get accurate and reproducible results for the studies that tell us most about the effects of EMF on humans. Based on some “weak” evidence suggesting an association between exposure to radiofrequency fields (RF emitted from mobile phones and two types of brain cancer, glioma and acoustic neuroma, the International Agency for Research on Cancer has classified RF as ‘possibly carcinogenic to humans’ in group 2B. Literature results suggest that pulsed microwaves from working environment can be the cause of genetic and cell alterations. Taken together, the increased frequency of DNA damages, increased intensity of oxydative stress and production of reactive oxygen species as well as prolonged disruption in DNA repair mechanisms could be possible mechanisms for microwave induced cytogenetic damages even at low-level electromagnetic fields. Although there were contradictory results about harmful effects of electromagnetic fields we recommend that the mobile phone should be kept as far as possible from the body during conversations and also during usual daily activities to reduce the absorption of radiation by cells. In addition, the appropriate intake of antioxidant-rich food or drugs may be helpful for preventing the genotoxic effects that could be caused by mobile phone use.

  10. Mutagenic and morphologic impacts of 1.8 GHz radiofrequency radiation on human peripheral blood lymphocytes (hPBLs) and possible protective role of pre-treatment with Ginkgo biloba (EGb 761)

    Energy Technology Data Exchange (ETDEWEB)

    Esmekaya, Meric Arda, E-mail: mericarda@yahoo.com [Department of Biophysics, Gazi University, Faculty of Medicine and Gazi Non-ionizing Radiation, Protection (GNRP) Center, Ankara (Turkey); Aytekin, Ebru [Department of Medical Genetics, Gazi University Faculty of Medicine, Ankara (Turkey); Ozgur, Elcin; Gueler, Goeknur [Department of Biophysics, Gazi University, Faculty of Medicine and Gazi Non-ionizing Radiation, Protection (GNRP) Center, Ankara (Turkey); Ergun, Mehmet Ali [Department of Medical Genetics, Gazi University Faculty of Medicine, Ankara (Turkey); Oemeroglu, Suna [Department of Histology and Embryology, Gazi University, Faculty of Medicine, Ankara (Turkey); Seyhan, Nesrin [Department of Biophysics, Gazi University, Faculty of Medicine and Gazi Non-ionizing Radiation, Protection (GNRP) Center, Ankara (Turkey)

    2011-12-01

    The mutagenic and morphologic effects of 1.8 GHz Global System for Mobile Communications (GSM) modulated RF (radiofrequency) radiation alone and in combination with Ginkgo biloba (EGb 761) pre-treatment in human peripheral blood lymphocytes (hPBLs) were investigated in this study using Sister Chromatid Exchange (SCE) and electron microscopy. Cell viability was assessed with 3-(4, 5-dimethylthiazol-2-yl)-2, 5-diphenyltetrazolium bromide (MTT) reduction assay. The lymphocyte cultures were exposed to GSM modulated RF radiation at 1.8 GHz for 6, 8, 24 and 48 h with and without EGb 761. We observed morphological changes in pulse-modulated RF radiated lymphocytes. Longer exposure periods led to destruction of organelle and nucleus structures. Chromatin change and the loss of mitochondrial crista occurred in cells exposed to RF for 8 h and 24 h and were more pronounced in cells exposed for 48 h. Cytoplasmic lysis and destruction of membrane integrity of cells and nuclei were also seen in 48 h RF exposed cells. There was a significant increase (p < 0.05) in SCE frequency in RF exposed lymphocytes compared to sham controls. EGb 761 pre-treatment significantly decreased SCE from RF radiation. RF radiation also inhibited cell viability in a time dependent manner. The inhibitory effects of RF radiation on the growth of lymphoctes were marked in longer exposure periods. EGb 761 pre-treatment significantly increased cell viability in RF + EGb 761 treated groups at 8 and 24 h when compared to RF exposed groups alone. The results of our study showed that RF radiation affects cell morphology, increases SCE and inhibits cell proliferation. However, EGb 761 has a protective role against RF induced mutagenity. We concluded that RF radiation induces chromosomal damage in hPBLs but this damage may be reduced by EGb 761 pre-treatment. - Highlights: Black-Right-Pointing-Pointer RF Radiation inhibits cell proliferation. Black-Right-Pointing-Pointer RF radiation induces chromosomal damage

  11. Effect of Electromagnetic Radiation Emitted from A Mobile Phone Station on Biochemical and Histological Structure of Some Rat Organs

    International Nuclear Information System (INIS)

    Lotfi, S.A.

    2011-01-01

    This study was carried out to investigate the effects of electromagnetic radiations (EMR), especially radio frequency (RF), which arises from mobile phone station on some parameter in serum and histological structure of some organs in male albino rats exposed to short (15 days) and long (30 days) periods. The long time exposure of the electromagnetic radiations can induce significant increase in the levels of testosterone, creatinine, urea and uric acid in the two exposure groups (15 and 30 days), while the serum total protein, albumin and globulin were decreased significantly after the long time of exposure as compared with control. The microscopic examination of liver, kidney and testes tissues revealed destruction and atrophy of cells in rats exposed to RF for 15 and 30 days. In conclusion, long term exposure of mobile phones station (EMR) induced harmful effects on blood parameter and histological structure of liver, kidney and testes tissues of rats.

  12. The electronics in fluorescent bulbs and light emitting diodes (LED), rather than ultraviolet radiation, cause increased malignant melanoma incidence in indoor office workers and tanning bed users.

    Science.gov (United States)

    Milham, Samuel; Stetzer, Dave

    2018-07-01

    The epidemiology of cutaneous malignant melanoma (CMM) has a number of facets that do not fit with sunlight and ultraviolet light as the primary etiologic agents. Indoor workers have higher incidence and mortality rates of CMM than outdoor workers; CMM occurs in body locations never exposed to sunlight; CMM incidence is increasing in spite of use of UV blocking agents and small changes in solar radiation. Installation of two new fluorescent lights in the milking parlor holding area of a Minnesota dairy farm in 2015 caused an immediate drop in milk production. This lead to measurement of body amperage in humans exposed to modern non-incandescent lighting. People exposed to old and new fluorescent lights, light emitting diodes (LED) and compact fluorescent lights (CFL) had body amperage levels above those considered carcinogenic. We hypothesize that modern electric lighting is a significant health hazard, a carcinogen, and is causing increasing CMM incidence in indoor office workers and tanning bed users. These lights generate dirty electricity (high frequency voltage transients), radio frequency (RF) radiation, and increase body amperage, all of which have been shown to be carcinogenic. This could explain the failure of ultraviolet blockers to stem the malignant melanoma pandemic. Tanning beds and non-incandescent lighting could be made safe by incorporating a grounded Faraday cage which allows passage of ultraviolet and visible light frequencies and blocks other frequencies. Modern electric lighting should be fabricated to be electrically clean. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. Shielding Efficiency of a Fabric Based on Amorphous Glass-Covered Magnetic Microwires to Radiation Emitted by a Mobile Phone in 2G and 3G Communication Technologies

    Directory of Open Access Journals (Sweden)

    Miclăuş Simona

    2017-12-01

    Full Text Available A dual band mobile phone model was used to check the shielding properties of an amorphous ferromagnetic textile against the radiation emitted by the handset. Two frequencies belonging to the 2nd and 3rd generation of mobile emission technologies were used, 897 MHz and 1950 MHz. The specific absorption rate (SAR of energy deposition in a human head phantom was measured in standardized conditions. The textile contained micrometric-diameter wires of a ferromagnetic mixture embedded in a thin glass coat and weaved in a specific way. A set of fabric orientations and configurations (layering were provided in the experiment in order to achieve a better shielding to the phone’s radiation. Compared with the non-shielded handset, SAR deposited in the head while using the fabric-covered phone could be decreased up to 30 % of its initial value – in case of 2G technology and up to 24 % – in case of 3G technology. This type of material shows one of the highest shielding efficiencies of the electric-field component in near-field exposure conditions reported until now. A cubic curve of SAR decrease in depth of the head was revealed in both uncovered and covered handset, the effect of shielding being larger at the higher frequency.

  14. Instrument development for atmospheric radiation measurement (ARM): Status of the Atmospheric Emitted Radiance Interferometer - extended Resolution (AERI-X), the Solar Radiance Transmission Interferometer (SORTI), and the Absolute Solar Transmission Inferometer (ASTI)

    Energy Technology Data Exchange (ETDEWEB)

    Murcray, F.; Stephen, T.; Kosters, J. [Univ. of Denver, CO (United States)

    1996-04-01

    This paper describes three instruments currently under developemnt for the Atmospheric Radiation Measurement (ARM) Program at the University of Denver: the AERI-X (Atmospheric Emitted Radiance Interferometer-Extended Resolution) and the SORTI (Solar R adiance Transmission Interferometer), and ASTI (Absolute Solar transmission Interferometer).

  15. [Occupational exposure of welders to ultraviolet and "blue light" radiation emitted during TIG and MMA welding based on field measurements].

    Science.gov (United States)

    Wolska, Agnieszka

    2013-01-01

    The aim of the study was to present the results of welders' occupational exposure to "blue light" and UV radiation carried out at industrial workstations during TIG and MMA welding. Measurements were performed at 13 workstations (TIG welding: 6; MMA welding: 7), at which different welding parameters and materials were used. The radiation level was measured using a wide-range radiometer and a set of detectors, whose spectral responses were adequately fit to particular hazard under study. The measurement points corresponded with the location of eye and hand. The highest values of eye irradiance were found for aluminum TIG welding. Effective irradiance of actinic UV was within the range E(s) = 7.79-37.6 W/m2; UVA total irradiance, E(UVA) = 18-53.1 W/m2 and effective blue-light irradiance E(B) = 35-67 W/m2. The maximum allowance time ranged from 1.7 to 75 s, which means that in some cases even unintentional very short eye exposure can exceed MPE. The influence of welded material and the type of electrode coating on the measured radiation level were evidenced. The exceeded value of MPE for photochemical hazard arising for the eyes and skin was found at all measured workstations. Welders should use appropriately the eye and face protective equipment and avoid direct staring at welding arc when starting an arc-welding operation. Besides, the lack of head and neck skin protection can induce acute and chronic harmful health effects. Therefore, an appropriate wear of personal protective equipment is essential for welders' health.

  16. Occupational exposure of welders to ultraviolet and "blue light" radiation emitted during TIG and MMA welding based on field measuremants

    Directory of Open Access Journals (Sweden)

    Agnieszka Wolska

    2013-02-01

    Full Text Available Background: The aim of the study was to present the results of welders' occupational exposure to "blue light" and UV radiation carried out at industrial workstations during TIG and MMA welding. Materials and methods: Measurements were performed at 13 workstations (TIG welding: 6; MMA welding: 7, at which different welding parameters and materials were used. The radiation level was measured using a wide-range radiometer and a set of detectors, whose spectral responses were adequately fit to particular hazard under study. The measurement points corresponded with the location of eye and hand. Results: The highest values of eye irradiance were found for aluminum TIG welding. Effective irradiance of actinic UV was within the range Es = 7.79-37.6 W/m2; UVA total irradiance, EUVA = 18-53.1 W/m2 and effective blue-light irradiance EB = 35-67 W/m2. The maximum allowance time ranged from 1.7 to 75 s, which means that in some cases even unintentional very short eye exposure can exceed MPE. Conclusions: The influence of welded material and the type of electrode coating on the measured radiation level were evidenced. The exceeded value of MPE for photochemical hazard arising for the eyes and skin was found at all measured workstations. Welders should use appropriately the eye and face protective equipment and avoid direct staring at welding arc when starting an arcwelding operation. Besides, the lack of head and neck skin protection can induce acute and chronic harmful health effects. Therefore, an appropriate wear of personal protective equipment is essential for welders' health. Med Pr 2013;64(1:69–82

  17. Freescale Sdn Bhd: Monitoring Radiofrequency Assessment

    International Nuclear Information System (INIS)

    Wan Saffiey Wan Abdullah; Noor Ezati Shuib; Rozaimah Abdul Rahim; Pasupathy, E.; Muhammad Yusri Yahaya

    2015-01-01

    Freescale Semiconductor (M) Sdn Bhd, requested the assistance of Malaysian Nuclear Agency (Nuclear Malaysia) to conduct an electromagnetic radiation (Radiofrequency Radiation) measurements around its facilities at Freescale Semiconductor (M) Sdn Bhd, 2, Jalan SS8/2, Sungai Wai Free Industrial Zone, 47300 Petaling Jaya, Selangor. Nuclear Agency Non-Ionising Radiation (NIR) Group carried out the measurement on 30th July 2012. In carrying out the work, the Group was assisted by Mr Daniel. The main objectives of the measurement were to assess the presence of electromagnetic radiation (RF field) in an accessible work places within and around the facilities and to advise the company on outcomes of the assessment and measurement based on international recommendations of standard guidelines issued by Malaysian Communication and Multimedia Commission (MCMC) and International Commission on Non-Ionising Radiation Protection (ICNIRP). (author)

  18. Biophysical evaluation of radiofrequency electromagnetic field effects on male reproductive pattern.

    Science.gov (United States)

    Kesari, Kavindra Kumar; Kumar, Sanjay; Nirala, Jayprakash; Siddiqui, Mohd Haris; Behari, Jitendra

    2013-03-01

    There are possible hazardous health effects of exposure to radiofrequency electromagnetic radiations emitted from mobile phone on the human reproductive pattern. It is more effective while keeping mobile phones in pocket or near testicular organs. Present review examines the possible concern on radio frequency radiation interaction and biological effects such as enzyme induction, and toxicological effects, including genotoxicity and carcinogenicity, testicular cancer, and reproductive outcomes. Testicular infertility or testicular cancer due to mobile phone or microwave radiations suggests an increased level of reactive oxygen species (ROS). Though generation of ROS in testis has been responsible for possible toxic effects on physiology of reproduction, the reviews of last few decades have well established that these radiations are very harmful and cause mutagenic changes in reproductive pattern and leads to infertility. The debate will be focused on bio-interaction mechanism between mobile phone and testicular cancer due to ROS formation. This causes the biological damage and leads to several changes like decreased sperm count, enzymatic and hormonal changes, DNA damage, and apoptosis formation. In the present review, physics of mobile phone including future research on various aspects has been discussed.

  19. Comments on Meo et al. Association of Exposure to Radio-Frequency Electromagnetic Field Radiation (RF-EMFR Generated by Mobile Phone Base Stations with Glycated Hemoglobin (HbA1c and Risk of Type 2 Diabetes Mellitus. Int. J. Environ. Res. Public Health, 2015, 12, 14519–14528

    Directory of Open Access Journals (Sweden)

    Seyed Alireza Mortazavi

    2016-02-01

    Full Text Available With great interest and enthusiasm, we have read the article by Meo et al. entitled “Association of Exposure to Radio-Frequency Electromagnetic Field Radiation (RF-EMFR Generated by Mobile Phone Base Stations with Glycated Hemoglobin (HbA1c and Risk of Type 2 Diabetes Mellitus” that is published in the latest issue of the International Journal of Environmental Research and Public Health [1].[...

  20. Fast beam radiofrequency spectroscopy

    International Nuclear Information System (INIS)

    Pipkin, F.M.

    1983-01-01

    The combination of a fast atom or ion beam derived from a small accelerator with radiofrequency spectroscopy methods provides a powerful method for measuring the fine structure of atomic and molecular systems. The fast beam makes possible measurements in which two separated oscillatory fields are used to obtain resonance lines whose widths are less than the natural line width due to the lifetimes of the states. The separated oscillatory field lines have, in addition, a number of features which make possible measurements with greater precision and less sensitivity to systematic errors. The fast beam also makes accessible multiple photon radiofrequency transitions whose line width is intrinsically narrower than that of the single photon transitions and which offer great potential for high precision measurements. This report focuses on the techniques and their promise. Recent measurements of the fine structure of H and He + are used as illustrations

  1. WORKSHOP: Radiofrequency superconductivity

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1984-10-15

    The Second Workshop on Radiofrequency Superconductivity was held at CERN from 23-27 July, four years after the first, organized at Karlsruhe. 35 invited talks were presented to the about 80 participants from Australia, Brazil, Europe, Japan and the United States. For the first time, ten Laboratories operating or planning superconducting accelerators for heavy ions participated and shared their experience with the community proposing the use of superconducting accelerating sections for electron accelerators.

  2. WORKSHOP: Radiofrequency superconductivity

    International Nuclear Information System (INIS)

    Anon.

    1984-01-01

    The Second Workshop on Radiofrequency Superconductivity was held at CERN from 23-27 July, four years after the first, organized at Karlsruhe. 35 invited talks were presented to the about 80 participants from Australia, Brazil, Europe, Japan and the United States. For the first time, ten Laboratories operating or planning superconducting accelerators for heavy ions participated and shared their experience with the community proposing the use of superconducting accelerating sections for electron accelerators

  3. The sensitivity of tropical convective precipitation to the direct radiative forcings of black carbon aerosols emitted from major regions

    Directory of Open Access Journals (Sweden)

    C. Wang

    2009-10-01

    Full Text Available Previous works have suggested that the direct radiative forcing (DRF of black carbon (BC aerosols are able to force a significant change in tropical convective precipitation ranging from the Pacific and Indian Ocean to the Atlantic Ocean. In this in-depth analysis, the sensitivity of this modeled effect of BC on tropical convective precipitation to the emissions of BC from 5 major regions of the world has been examined. In a zonal mean base, the effect of BC on tropical convective precipitation is a result of a displacement of ITCZ toward the forcing (warming hemisphere. However, a substantial difference exists in this effect associated with BC over different continents. The BC effect on convective precipitation over the tropical Pacific Ocean is found to be most sensitive to the emissions from Central and North America due to a persistent presence of BC aerosols from these two regions in the lowermost troposphere over the Eastern Pacific. The BC effect over the tropical Indian and Atlantic Ocean is most sensitive to the emissions from South as well as East Asia and Africa, respectively. Interestingly, the summation of these individual effects associated with emissions from various regions mostly exceeds their actual combined effect as shown in the model run driven by the global BC emissions, so that they must offset each other in certain locations and a nonlinearity of this type of effect is thus defined. It is known that anthropogenic aerosols contain many scattering-dominant constituents that might exert an effect opposite to that of absorbing BC. The combined aerosol forcing is thus likely differing from the BC-only one. Nevertheless, this study along with others of its kind that isolates the DRF of BC from other forcings provides an insight of the potentially important climate response to anthropogenic forcings particularly related to the unique particulate solar absorption.

  4. Radiofrequency fields in our surroundings; Radiofrekvente felt i vaare omgivelser

    Energy Technology Data Exchange (ETDEWEB)

    2011-07-01

    In 2010, the National Radiation Protection Authority (NRPA) with the Post and Telecommunications Authority carried out a project where it is measured radiofrequency fields from various telecom systems in homes, kindergartens, schools, offices, and urban environments. Close to 99 percent of the measurement points were found values of less than one thousandth of the maximum. No values were near the limits. (AG)

  5. Radiofrequency in cosmetic dermatology.

    Science.gov (United States)

    Beasley, Karen L; Weiss, Robert A

    2014-01-01

    The demand for noninvasive methods of facial and body rejuvenation has experienced exponential growth over the last decade. There is a particular interest in safe and effective ways to decrease skin laxity and smooth irregular body contours and texture without downtime. These noninvasive treatments are being sought after because less time for recovery means less time lost from work and social endeavors. Radiofrequency (RF) treatments are traditionally titrated to be nonablative and are optimal for those wishing to avoid recovery time. Not only is there minimal recovery but also a high level of safety with aesthetic RF treatments. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Potential Hazards of Cellular Phone Radiation: Responses to Fear and Uncertainty

    OpenAIRE

    Wisz, Jamie T.

    2002-01-01

    In recent years, the public has become concerned that the electromagnetic radio-frequency radiation (“RF radiationâ€) emitted by cellular telephones may pose serious health risks, including the risk of cancer. There are over 110 million cell phone users in the United States and many of them may not know that cell phones actually send electromagnetic waves into the user’s brain. Depending on how close the cell phone antenna is to oneâ&euro...

  7. Exposure of Ontario workers to radiofrequency fields from dielectric heaters

    International Nuclear Information System (INIS)

    Bitran, M.E.; Nishio, J.M.; Charron, D.E.

    1992-01-01

    As part of a program to assess and reduce the exposure of Ontario workers to non-ionizing radiations, stray electric and magnetic fields from 383 dielectric heaters were measured in 71 industrial establishments from 1988 to 1990. This represents a population of over 800 workers potentially exposed to radiofrequency (RE) electromagnetic fields. Electric and magnetic field strengths at the head, waist, and thigh levels of the operators, corrected by duty cycle, are presented for the different heater types surveyed. Worker exposure data and compliance with Ontario radiofrequency exposure guidelines are discussed. (author)

  8. Radiofrequency Ablation Effectively Treated Focal Recurrence of Mesothelioma.

    Science.gov (United States)

    Nakamura, Akifumi; Takuwa, Teruhisa; Hashimoto, Masaki; Kondo, Nobuyuki; Takaki, Haruyuki; Fujiwara, Masayuki; Yamakado, Koichiro; Hasegawa, Seiki

    2018-02-01

    A 55-year-old man with malignant pleural mesothelioma underwent multimodality treatment comprising induction chemotherapy followed by extrapleural pneumonectomy and radiation therapy. After 2.5 years, focal recurrence occurred, with computed tomography revealing a tumor in the left cardiophrenic angle. Surgery was considered a problem for the patient because of the previous extrapleural pneumonectomy and difficult tumor location. Radiofrequency ablation was thus performed; the course was uneventful, and there was no recurrence. Radiofrequency ablation should be considered an option to treat recurrence of malignant pleural mesothelioma. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Radiofrequency ablation of pulmonary tumors

    Energy Technology Data Exchange (ETDEWEB)

    Crocetti, Laura, E-mail: l.crocetti@med.unipi.i [Division of Diagnostic Imaging and Intervention, Department of Liver Transplants, Hepatology and Infectious Diseases, Pisa University School of Medicine (Italy); Lencioni, Riccardo [Division of Diagnostic Imaging and Intervention, Department of Liver Transplants, Hepatology and Infectious Diseases, Pisa University School of Medicine (Italy)

    2010-07-15

    The development of image-guided percutaneous techniques for local tumor ablation has been one of the major advances in the treatment of solid tumors. Among these methods, radiofrequency (RF) ablation is currently established as the primary ablative modality at most institutions. RF ablation is accepted as the best therapeutic choice for patients with early-stage hepatocellular carcinoma when liver transplantation or surgical resection are not suitable options and is considered as a viable alternate to surgery for inoperable patients with limited hepatic metastatic disease, especially from colorectal cancer. Recently, RF ablation has been demonstrated to be a safe and valuable treatment option for patients with unresectable or medically inoperable lung malignancies. Resection should remain the standard therapy for non-small cell lung cancer (NSCLC) but RF ablation may be better than conventional external-beam radiation for the treatment of the high-risk individual with NSCLC. Initial favourable outcomes encourage combining radiotherapy and RF ablation, especially for treating larger tumors. In the setting of colorectal cancer lung metastases, survival rates provided by RF ablation in selected patients, are substantially higher than those obtained with any chemotherapy regimens and provide indirect evidence that RF ablation therapy improves survival in patients with limited lung metastatic disease.

  10. Microwave discharge electrodeless lamps (MDEL). III. A novel tungsten-triggered MDEL device emitting VUV and UVC radiation for use in wastewater treatment.

    Science.gov (United States)

    Horikoshi, Satoshi; Miura, Takashi; Kajitani, Masatsugu; Serpone, Nick

    2008-03-01

    Exposure to low doses of the xenoestrogen bisphenol A (BPA) and to the hormonal 2,4-dichlorophenoxyacetic acid (2,4-D) herbicide, an environmental endocrine disruptor, can have serious health consequences such as the induction of mammary gland ductal hyperplasias and carcinoma (LaChapelle et al., Reprod. Toxicol., 2007, 23, 20; Murray et al., Reprod. Toxicol., 2007, 23, 383). To the extent that these toxins are present in wastewaters (Donald et al., Sci. Total Environ. 1999, 231, 173; Brotons et al., Environ. Health Perspect. 1994, 103, 608; Olea et al., Environ. Health Perspect. 1996, 104, 298; Biles et al., J. Agric. Food Chem. 1997, 45, 3541; Markey et al., J. Steroid Biochem. Mol. Biol., 2003, 83, 235), we examined their oxidative destruction in aqueous media by a novel light source. A tungsten-triggered microwave discharge electrodeless lamp (W-MDEL) was fabricated for possible use in wastewater treatment using vacuum UV-transparent quartz in which a tungsten trigger, also embedded in quartz, was attached to the MDEL to aid in the self-ignition of the lamp on irradiation at low microwave power levels. The quantity of mercury gas in the W-MDEL was optimized by monitoring the continuous radiation and peak intensities of the emitted light in the vacuum UV (VUV) and UVC regions. The usefulness of the W-MDEL device was assessed through the degradation of 2,4-D and BPA in air-equilibrated aqueous media and in oxygen-saturated aqueous media. Enhanced degradation of these two xenoestrogenic toxins was achieved by increasing the number of W-MDEL devices while keeping constant the microwave radiation feeding each W-MDEL lamp. This novel lamp provides an additional light source in the photooxidation of environmental contaminants without the need for a metal-oxide photocatalyst. Under our conditions, process dynamics using the W-MDEL light source are greater than with the more conventional photochemical methods that employ low-pressure Hg arc electrode lamps in synthetic

  11. Monte Carlo simulation of age-dependent radiation dose from alpha- and beta-emitting radionuclides to critical trabecular bone and bone marrow targets

    Science.gov (United States)

    Dant, James T.; Richardson, Richard B.; Nie, Linda H.

    2013-05-01

    Alpha (α) particles and low-energy beta (β) particles present minimal risk for external exposure. While these particles can induce leukemia and bone cancer due to internal exposure, they can also be beneficial for targeted radiation therapies. In this paper, a trabecular bone model is presented to investigate the radiation dose from bone- and marrow-seeking α and β emitters to different critical compartments (targets) of trabecular bone for different age groups. Two main issues are addressed with Monte Carlo simulations. The first is the absorption fractions (AFs) from bone and marrow to critical targets within the bone for different age groups. The other issue is the application of 223Ra for the radiotherapy treatment of bone metastases. Both a static model and a simulated bone remodeling process are established for trabecular bone. The results show significantly lower AFs from radionuclide sources in the bone volume to the peripheral marrow and the haematopoietic marrow for adults than for newborns and children. The AFs from sources on the bone surface and in the bone marrow to peripheral marrow and haematopoietic marrow also varies for adults and children depending on the energy of the particles. Regarding the use of 223Ra as a radionuclide for the radiotherapy of bone metastases, the simulations show a significantly higher dose from 223Ra and its progeny in forming bone to the target compartment of bone metastases than that from two other more commonly used β-emitting radiopharmaceuticals, 153Sm and 89Sr. There is also a slightly lower dose from 223Ra in forming bone to haematopoietic marrow than that from 153Sm and 89Sr. These results indicate a higher therapy efficiency and lower marrow toxicity from 223Ra and its progeny. In conclusion, age-related changes in bone dimension and cellularity seem to significantly affect the internal dose from α and β emitters in the bone and marrow to critical targets, and 223Ra may be a more efficient

  12. Bray–Liebhafsky oscillatory reaction in the radiofrequency electromagnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Stanisavljev, Dragomir R., E-mail: dragisa@ffh.bg.ac.rs [Faculty of Physical Chemistry, University of Belgrade, Studentski trg 12-16, P.O. Box 473, 11001 Belgrade (Serbia); Velikić, Zoran [Institute of Physics, University of Belgrade, Pregrevica 118, Zemun (Serbia); Veselinović, Dragan S.; Jacić, Nevena V.; Milenković, Maja C. [Faculty of Physical Chemistry, University of Belgrade, Studentski trg 12-16, P.O. Box 473, 11001 Belgrade (Serbia)

    2014-09-30

    Highlights: • Oscillatory Bray–Liebhafsky reaction is coupled with the radiofrequency radiation. • The effects of radiofrequency field on oscillatory parameters are investigated. • Radiofrequency power of up to the 0.2 W did not produced observable changes. • The explanation related with dissipative and capacitive effects is given. • Open the possibility of investigations of reactive effects on biological systems. - Abstract: Oscillatory Bray–Liebhafsky (BL) reaction is capacitively coupled with the electromagnetic radiation in the frequency range 60–110 MHz. Because of the specific reaction dynamics characterized by several characteristic parameters (induction period, period between chemical oscillations and their amplitude) it served as a good model system for the investigation of the effects of radiofrequent (RF) radiation. RF power of up to 0.2 W did not produce observable changes of the BL reaction parameters in the limit of the experiment reproductivity. Results indicate that, under the given experimental conditions, both dissipative and reactive properties of the solution are not considerably coupled with the RF electrical field.

  13. Radiofrequency catheter ablation in the treatment of cardiac arrhythmias (first of two parts)

    International Nuclear Information System (INIS)

    Kou, W.H; Morady, F.

    1997-01-01

    The intravenous radiofrequency catheter inside cardiac s chambers, for inspect signals intracardiac s and to encourage, has been developed as diagnostic tool with the purpose to search arrhythmias physiology and physiopathology.Many energy sources has been used: direct energy, radiofrequency 11-15, laser 6,17, and microwave 18,19. A comparison between radiofrequency and electric energy shock has been described in cardiac arrhythmias treatment, in the present article. It has been tested the radiation biological effects and risk in Wolff Parkinson White patients as well as doctors who handling the fluoroscopy for image during the radiofrequency ablation. Has been described the following techniques: Catheter ablation radiofrequency slow way and fast way

  14. Spectral investigation of hot-spot and cavity resonance effects on the terahertz radiation emitted from high-Tc superconducting Bi2Sr2CaCu2O8+δ single crystal mesa structures

    Science.gov (United States)

    Kadowaki, Kazuo; Watanabe, Chiharu; Minami, Hidetoshi; Yamamoto, Takashi; Kashiwagi, Takanari; Klemm, Richard

    2014-03-01

    Terahertz (THz) electromagnetic radiation emitted from high-Tc superconducting Bi2Sr2CaCu2O8+δ mesa structures in the case of single mesa and series-connected mesas is investigated by the FTIR spectroscopic technique while observing its temperature distribution simultaneously by a SiC photoluminescence technique. Changing the bias level, sudden jumps of the hot-spot position were clearly observed. Although the radiation intensity changes drastically associated with the jump of the hot spot position, the frequency is unaffected as long as the voltage per junction is kept constant. Since the frequency of the intense radiation satisfies the cavity resonance condition, we confirmed that the cavity resonance is of primarily importance for the synchronization of whole intrinsic Josephson junctions in the mesa for high power radiation. This work was supported in part by the Grant-in-Aid for challenging Exploratory Research, the Ministry of Education, Culture, Sports, Science & Technology (MEXT).

  15. Radiofrequency attenuator and method

    Science.gov (United States)

    Warner, Benjamin P [Los Alamos, NM; McCleskey, T Mark [Los Alamos, NM; Burrell, Anthony K [Los Alamos, NM; Agrawal, Anoop [Tucson, AZ; Hall, Simon B [Palmerston North, NZ

    2009-01-20

    Radiofrequency attenuator and method. The attenuator includes a pair of transparent windows. A chamber between the windows is filled with molten salt. Preferred molten salts include quarternary ammonium cations and fluorine-containing anions such as tetrafluoroborate (BF.sub.4.sup.-), hexafluorophosphate (PF.sub.6.sup.-), hexafluoroarsenate (AsF.sub.6.sup.-), trifluoromethylsulfonate (CF.sub.3SO.sub.3.sup.-), bis(trifluoromethylsulfonyl)imide ((CF.sub.3SO.sub.2).sub.2N.sup.-), bis(perfluoroethylsulfonyl)imide ((CF.sub.3CF.sub.2SO.sub.2).sub.2N.sup.-) and tris(trifluoromethylsulfonyl)methide ((CF.sub.3SO.sub.2).sub.3C.sup.-). Radicals or radical cations may be added to or electrochemically generated in the molten salt to enhance the RF attenuation.

  16. Electromagnetic field sources in radiofrequency

    International Nuclear Information System (INIS)

    Oliveira, C.; Sebastiao, D.; Ladeira, D.; Antunes, M.; Correia, L.M.

    2010-01-01

    In the scope of the monIT Project, several measurements were made of electromagnetic fields in Portugal. This paper presents an analysis of the sources operating in the radiofrequency range, resulting from 2429 measurements in 466 locations.

  17. The exemption from the requirement of registration and/or licensing of some sources. machines and devices emitting ionizing and /or on ionizing radiation: a proposed draft for Israeli regulations

    Energy Technology Data Exchange (ETDEWEB)

    Schlesinger, T; Margaliot, M [Israel Atomic Energy Commission, Yavne (Israel). Soreq Nuclear Research Center

    1997-11-16

    The licensing and authorization of the import, purchase, distribution, transportation and application of radioactive materials and devices emitting ionizing and/or non-ionizing radiation are carried out in Israel by the Ministries of the Environment and of Health. The legal basis for file authority of these Ministries in radiation protection matters is file {sup P}harmacists Regulation- Radioactive Elements and Products Thereof, 1981 (revision 1994) (PRREPT). Licenses are issued by the Chief Radiation Executive (CUE) appointed by the Minister of the Environment and the Minister of Health. The Regulations include a clause which enables the CUE to exempt certain amounts of radioactive materials from file requirements laid down in the PRREPT. The exemption clause is general and does not indicate the types and amounts of radioactive material may be exempted. The proposed draft Israeli regulations are related to exemption of some sources, machines and devices emitting ionizing and non-ionizing radiation, wife a suggestion to extend file above mentioned exemption clause to include some machines and devices and to provide an explicit and detailed list of materials, sources and devices to be exempted. Among these are the following: (authors)

  18. The exemption from the requirement of registration and/or licensing of some sources. machines and devices emitting ionizing and /or on ionizing radiation: a proposed draft for Israeli regulations

    International Nuclear Information System (INIS)

    Schlesinger, T.; Margaliot, M.

    1997-01-01

    The licensing and authorization of the import, purchase, distribution, transportation and application of radioactive materials and devices emitting ionizing and/or non-ionizing radiation are carried out in Israel by the Ministries of the Environment and of Health. The legal basis for file authority of these Ministries in radiation protection matters is file P harmacists Regulation- Radioactive Elements and Products Thereof, 1981 (revision 1994) (PRREPT). Licenses are issued by the Chief Radiation Executive (CUE) appointed by the Minister of the Environment and the Minister of Health. The Regulations include a clause which enables the CUE to exempt certain amounts of radioactive materials from file requirements laid down in the PRREPT. The exemption clause is general and does not indicate the types and amounts of radioactive material may be exempted. The proposed draft Israeli regulations are related to exemption of some sources, machines and devices emitting ionizing and non-ionizing radiation, wife a suggestion to extend file above mentioned exemption clause to include some machines and devices and to provide an explicit and detailed list of materials, sources and devices to be exempted. Among these are the following: (authors)

  19. The Precautionary Principle in the Context of Mobile Phone and Base Station Radiofrequency Exposures

    OpenAIRE

    Dolan, Mike; Rowley, Jack

    2009-01-01

    Background No health hazard has been established from exposure to radiofrequency fields up to the levels recommended by the International Commission on Non-Ionizing Radiation Protection. However, in response to public concern and the perceived level of scientific uncertainty, there are continuing calls for the application of the precautionary principle to radiofrequency exposures from mobile phones and base stations. Objective We examined the international evolution of calls for precautionary...

  20. 78 FR 25916 - Authorization of Radiofrequency Equipment

    Science.gov (United States)

    2013-05-03

    ...] Authorization of Radiofrequency Equipment AGENCY: Federal Communications Commission. ACTION: Proposed rule... bodies, and measurement procedures used to determine RF equipment compliance. The Commission believes... Commission is responsible for an equipment authorization program for radiofrequency (RF) devices under part 2...

  1. Report by the work-group on 'safety of medical devices emitting ionizing radiations'. Articulation of radiation protection requirements of the 97/43/Euratom directive and IAEA recommendations with the essential requirements of the 93/42/CEE directive related to medical devices used in external radiotherapy

    International Nuclear Information System (INIS)

    2010-01-01

    As some dysfunctions and events had been reported in 2007 and 2008 in field of radiotherapy, this report aims at clarifying the articulation between the different European regulations concerning medical devices emitting ionizing radiations and radiation protection. The authors report a survey with device manufacturers, and analyze the content of the different regulations and recommendations. Then, the authors recommend and propose a set of actions related to the IAEA requirements and recommendations, to CE marking requirements, and to new radiation protection and safety requirements present in the Euratom directive

  2. New-generation radiofrequency technology.

    Science.gov (United States)

    Krueger, Nils; Sadick, Neil S

    2013-01-01

    Radiofrequency (RF) technology has become a standard treatment in aesthetic medicine with many indications due to its versatility, efficacy, and safety. It is used worldwide for cellulite reduction; acne scar revision; and treatment of hypertrophic scars and keloids, rosacea, and inflammatory acne in all skin types. However, the most common indication for RF technology is the nonablative tightening of tissue to improve skin laxity and reduce wrinkles. Radiofrequency devices are classified as unipolar, bipolar, or multipolar depending on the number of electrodes used. Additional modalities include fractional RF; sublative RF; phase-controlled RF; and combination RF therapies that apply light, massage, or pulsed electromagnetic fields (PEMFs). This article reviews studies and case series on these devices. Radiofrequency technology for aesthetic medicine has seen rapid advancements since it was used for skin tightening in 2003. Future developments will continue to keep RF technology at the forefront of the dermatologist's armamentarium for skin tightening and rejuvenation.

  3. Radiated Emissions Test Approach

    Science.gov (United States)

    2015-10-02

    1. Draft Department of Transportation (DOT) Test Plan to Develop : Interference Tolerance Masks for GNSS Receivers in the L1 : Radiofrequency Band (1559 1610 MHz) provides high level : overview of radiated emissions test setup : 2. Presenta...

  4. Non-surgical radiofrequency facelift.

    Science.gov (United States)

    Narins, David J; Narins, Rhoda S

    2003-10-01

    There has been considerable interest in using non-ablative methods to rejuvenate the skin. The ThermaCool TC (Thermage Inc.) is a radiofrequency (RF) device that has been introduced to induce tightening of the address the problem of skin via a uniform volumetric heating into the deep dermis tightening, resulting in a 'non-surgical facelift'. Radiofrequency produces a uniform volumetric heating into the deep dermis. Twenty treatment areas in 17 patients were treated to evaluate the efficacy and safety of RF treatment to the brow and jowls. The technique was found to produce gradual tightening in most patients, and there were no adverse effects.

  5. Emerging indications of endoscopic radiofrequency ablation

    Science.gov (United States)

    Becq, Aymeric; Camus, Marine; Rahmi, Gabriel; de Parades, Vincent; Marteau, Philippe

    2015-01-01

    Introduction Radiofrequency ablation (RFA) is a well-validated treatment of dysplastic Barrett's esophagus. Other indications of endoscopic RFA are under evaluation. Results Four prospective studies (total 69 patients) have shown that RFA achieved complete remission of early esophageal squamous intra-epithelial neoplasia at a rate of 80%, but with a substantial risk of stricture. In the setting of gastric antral vascular ectasia, two prospective monocenter studies, and a retrospective multicenter study, (total 51 patients), suggest that RFA is efficacious in terms of reducing transfusion dependency. In the setting of chronic hemorrhagic radiation proctopathy, a prospective monocenter study and a retrospective multicenter study (total 56 patients) suggest that RFA is an efficient treatment. A retrospective comparative study (64 patients) suggests that RFA improves stents patency in malignant biliary strictures. Conclusions Endoscopic RFA is an upcoming treatment modality in early esophageal squamous intra-epithelial neoplasia, as well as in gastric, rectal, and biliary diseases. PMID:26279839

  6. Radiofrequency Radiation Dosimetry Handbook. 4th Edition

    Science.gov (United States)

    1986-10-01

    models versus distance . . . . . ................ . . . 8.23 I 8.21. Heasured relative fields versus distance for the thick monopole on a grounded plane...8.1. Measured and calculated values of average SAR for live mice ...... ..... ...................... 8.51 8.2. Measured and calculated values of average...basis for the concept of the in vivo probe measurement is found in an antenna modeling theorem (Burdette et al., 1980) that applies to a short monopole

  7. Emitting recombination of BCl molecules with chlorine atoms, resulting from dissociation of boron trichloride molecules under action of pulse CO2-laser radiation

    International Nuclear Information System (INIS)

    Nikonorov, A.P.; Moskvitina, E.N.; Kuzyakov, Yu.Ya.; Stepanov, P.I.

    1983-01-01

    Luminescence in BCl 3 is investigated. The results of measurements of gas temperature, BCl molecules concentration, and luminescence absolute intensity at boron trichloride presure of 40 mm pH and density of laser pulse energy from 1.7 up to 4.0 J/cm 2 are obtained. Nature of uninterrupted spectrum is considered. It is established that luminescence appearing in the BCl 3 under action of pulse CO 2 -laser is caused by reaction of emitting recombination of BCl molecules with chlorine atoms. Rate constant of this reaction in the range of 2300-3100 K is determined

  8. A multi-layer discrete-ordinate method for vector radiative transfer in a vertically-inhomogeneous, emitting and scattering atmosphere. I - Theory. II - Application

    Science.gov (United States)

    Weng, Fuzhong

    1992-01-01

    A theory is developed for discretizing the vector integro-differential radiative transfer equation including both solar and thermal radiation. A complete solution and boundary equations are obtained using the discrete-ordinate method. An efficient numerical procedure is presented for calculating the phase matrix and achieving computational stability. With natural light used as a beam source, the Stokes parameters from the model proposed here are compared with the analytical solutions of Chandrasekhar (1960) for a Rayleigh scattering atmosphere. The model is then applied to microwave frequencies with a thermal source, and the brightness temperatures are compared with those from Stamnes'(1988) radiative transfer model.

  9. WORKSHOP: Radiofrequency superconductivity

    International Nuclear Information System (INIS)

    Tückmantel, Joachim

    1993-01-01

    Full text: With superconducting radiofrequency playing a major role in the push for new machines to break fresh physics frontiers, it has become a tradition for experts and newcomers in this field from all over the world to meet every second year to hear progress reports from laboratories and to discuss common problems and possible solutions. The sixth such workshop was held from 4-8 October under the chairmanship of Ron Sundelin at the Continuous Electron Beam Accelerator Facility (CEBAF) under construction in Newport News, Virginia. With 170 participants from 14 countries including Eastern Europe and China, it reflected the growing interest in the field - looking back to 1984, when CERN was the host laboratory, the second workshop had less than 100 participants. The CEBAF meeting began with laboratory status reports, covering both high beam energy ('high beta') applications with 'spherical' cavities (as with CERN's LEP200), all using niobium as superconductor and working between 352 MHz and 3 GHz, and lower energy (low beta') applications with geometrically more complicated shapes such as quarter or half wave, split ring or spoke resonators, some using electrodeposited lead as superconductor and working around 100 MHz. During these talks it became clear that more and more laboratories have focused on routine problems, such as reliable series production and testing, running cavities with ancillaries in the machines, or building complete prototypes for projects to be approved by critical funding authorities. This contrasts with the heady days just a few years ago when - at least in the high beta community - the main objective was to explore new ideas. State-of-the-art summaries showed how at 1.3 and 3 GHz 25-30 MV/m have been reached by several laboratories using different preparation methods. Newer developments for common problems included r.f. windows, couplers, controls, and especially field emission, public enemy number one for

  10. Radiation and the New Zealand community : a scientific overview

    International Nuclear Information System (INIS)

    1998-01-01

    This book is intended to give information and perspective on the risks associated with the widespread use of radiations of different types in modern society. Chapter 1 introduces the radiations that are discussed. It raises questions, which the book seeks to answer about risks and benefits of radiation applications, and discusses the meaning of the oft-quoted expression n uclear free . Chapter 2 briefly describes the nature of radioactivity and the types of radioactive decay processes and emitted radiations most commonly observed. Chapter 3 traces from the perspective of historical developments the use of x-rays and radioactive materials in medical practice. Chapter 4 outlines the wide range of applications of radioactive materials in x-ray equipment in industry with particular emphasis on applications in New Zealand. Chapter 5 is devoted to a description of food irradiation. Chapter 6 is devoted to non-ionizing radiation applications, with separate sections on ultraviolet radiation, visible radiation, lasers, infrared radiation, microwave and radiofrequency radiation ,with some particular reference to cellular phone systems, extremely low frequency electric and magnetic fields and ultrasound. Chapter 7 concludes with an outline of the system of controls on ionizing radiation sources in New Zealand. (author). 7 appendices

  11. Radiofrequency electromagnetic fields in the Cookridge area of Leeds

    CERN Document Server

    Fuller, K; Judd, P M; Lowe, A J; Shaw, J

    2002-01-01

    On the 8 and 9 May 2002 representatives of the National Radiological Protection Board (NRPB) performed a radiofrequency electromagnetic field survey in the Cookridge area of Leeds in order to assess exposure to radio signals from transmitters mounted on a water tower/a lattice tower and a radio station tower. Guidelines on limiting exposure to radio signals have been published by NRPB and the International Commission on Non-Ionizing Radiation Protection (ICNIRP). These guidelines are designed to prevent established adverse effects on human health. During this survey, the total exposures due to all radio signals from 30 MHz to 18000 MHz (18 GHz) were measured. This frequency range was chosen as it includes mobile phone base station transmissions, which are at around 900 and 1800 MHz and super high frequency (SHF) transmissions from most of the large microwave dish antennas mounted on the towers. In addition, other major sources of radiofrequency electromagnetic fields in the environment such as broadcast radio...

  12. Errors and limits in the determination of plasma electron density by measuring the absolute values of the emitted continuum radiation intensity

    International Nuclear Information System (INIS)

    Bilbao, L.; Bruzzone, H.; Grondona, D.

    1994-01-01

    The reliable determination of a plasma electron structure requires a good knowledge of the errors affecting the employed technique. A technique based on the measurements of the absolute light intensity emitted by travelling plasma structures in plasma focus devices has been used, but it can be easily modified to other geometries and even to stationary plasma structures with time-varying plasma densities. The purpose of this work is to discuss in some detail the errors and limits of this technique. Three separate errors are shown: the minimum size of the density structure that can be resolved, an overall error in the measurements themselves, and an uncertainty in the shape of the density profile. (author)

  13. Radiofrequency Ablation of Hepatic Cysts : Case Report

    International Nuclear Information System (INIS)

    Lee, Ye Ri; Kim, Pyo Nyun

    2005-01-01

    Radiofrequency ablation has been frequently performed on intra-hepatic solid tumor, namely, hepatocellular carcinoma, metastatic tumor and cholangio carcinoma, for take the cure. But, the reports of radiofrequency ablation for intrahepatic simple cysts are few. In vitro experiment of animal and in vivo treatment for intrahepatic cysts of human had been reported in rare cases. We report 4 cases of radiofrequency ablation for symptomatic intrahepatic cysts

  14. Superconducting Radio-Frequency Cavities

    Science.gov (United States)

    Padamsee, Hasan S.

    2014-10-01

    Superconducting cavities have been operating routinely in a variety of accelerators with a range of demanding applications. With the success of completed projects, niobium cavities have become an enabling technology, offering upgrade paths for existing facilities and pushing frontier accelerators for nuclear physics, high-energy physics, materials science, and the life sciences. With continued progress in basic understanding of radio-frequency superconductivity, the performance of cavities has steadily improved to approach theoretical capabilities.

  15. Recent developments in white light emitting diodes

    Science.gov (United States)

    Lohe, P. P.; Nandanwar, D. V.; Belsare, P. D.; Moharil, S. V.

    2018-05-01

    because they can emit visible light strongly under blue light irradiation. These are chemically, thermally and mechanically stable materials with high efficiency to down convert blue radiation into green and red. Efficient white light can be generated by coating these phosphors on blue LED.CRI of white emitting LED lamp can be improved significantly if green and red emitting phosphors are coated on efficient blue emitting LED chips. In this approach CRI will be maintained if appropriate combination of red, green along with blue emission is used. This article reviews some recent developments in phosphors for white light emitting diodes.

  16. Ab initio investigation of barium-scandium-oxygen coatings on tungsten for electron emitting cathodes

    Science.gov (United States)

    Vlahos, Vasilios; Booske, John H.; Morgan, Dane

    2010-02-01

    Microwave, x-ray, and radio-frequency radiation sources require a cathode emitting electrons into vacuum. Thermionic B-type dispenser cathodes consist of BaxOz coatings on tungsten (W), where the surface coatings lower the W work function and enhance electron emission. The new and promising class of scandate cathodes modifies the B-type surface through inclusion of Sc, and their superior emissive properties are also believed to stem from the formation of a low work function surface alloy. In order to better understand these cathode systems, density-functional theory (DFT)-based ab initio modeling is used to explore the stability and work function of BaxScyOz on W(001) monolayer-type surface structures. It is demonstrated how surface depolarization effects can be calculated easily using ab initio calculations and fitted to an analytic depolarization equation. This approach enables the rapid extraction of the complete depolarization curve (work function versus coverage relation) from relatively few DFT calculations, useful for understanding and characterizing the emitting properties of novel cathode materials. It is generally believed that the B-type cathode has some concentration of Ba-O dimers on the W surface, although their structure is not known. Calculations suggest that tilted Ba-O dimers are the stable dimer surface configuration and can explain the observed work function reduction corresponding to various dimer coverages. Tilted Ba-O dimers represent a new surface coating structure not previously proposed for the activated B-type cathode. The thermodynamically stable phase of Ba and O on the W surface was identified to be the Ba0.25O configuration, possessing a significantly lower Φ value than any of the Ba-O dimer configurations investigated. The identification of a more stable Ba0.25O phase implies that if Ba-O dimers cover the surface of emitting B-type cathodes, then a nonequilibrium steady state must dominate the emitting surface. The identification of

  17. Radiation-induced biologic bystander effect elicited in vitro by targeted radiopharmaceuticals labeled with alpha-, beta-, and auger electron-emitting radionuclides.

    Science.gov (United States)

    Boyd, Marie; Ross, Susan C; Dorrens, Jennifer; Fullerton, Natasha E; Tan, Ker Wei; Zalutsky, Michael R; Mairs, Robert J

    2006-06-01

    Recent studies have shown that indirect effects of ionizing radiation may contribute significantly to the effectiveness of radiotherapy by sterilizing malignant cells that are not directly hit by the radiation. However, there have been few investigations of the importance of indirect effects in targeted radionuclide treatment. Our purpose was to compare the induction of bystander effects by external beam gamma-radiation with those resultant from exposure to 3 radiohaloanalogs of metaiodobenzylguanidine (MIBG): (131)I-MIBG (low-linear-energy-transfer [LET] beta-emitter), (123)I-MIBG (potentially high-LET Auger electron emitter), and meta-(211)At-astatobenzylguanidine ((211)At-MABG) (high-LET alpha-emitter). Two human tumor cell lines-UVW (glioma) and EJ138 (transitional cell carcinoma of bladder)-were transfected with the noradrenaline transporter (NAT) gene to enable active uptake of MIBG. Medium from cells that accumulated the radiopharmaceuticals or were treated with external beam radiation was transferred to cells that had not been exposed to radioactivity, and clonogenic survival was determined in donor and recipient cultures. Over the dose range 0-9 Gy of external beam radiation of donor cells, 2 Gy caused 30%-40% clonogenic cell kill in recipient cultures. This potency was maintained but not increased by higher dosage. In contrast, no corresponding saturation of bystander cell kill was observed after treatment with a range of activity concentrations of (131)I-MIBG, which resulted in up to 97% death of donor cells. Cellular uptake of (123)I-MIBG and (211)At-MABG induced increasing recipient cell kill up to levels that resulted in direct kill of 35%-70% of clonogens. Thereafter, the administration of higher activity concentrations of these high-LET emitters was inversely related to the kill of recipient cells. Over the range of activity concentrations examined, neither direct nor indirect kill was observed in cultures of cells not expressing the NAT and, thus

  18. Synchrotron radiation

    International Nuclear Information System (INIS)

    Farge, Y.

    1982-01-01

    Synchrotron radiation is produced by electrons accelerated near the velocity of light in storage rings, which are used for high energy Physics experiments. The radiation light exhibits a wide spread continuous spectrum ranging from 01 nanometre to radiofrequency. This radiation is characterized by high power (several kilowatts) and intense brightness. The paper recalls the emission laws and the distinctive properties of the radiation, and gives some of the numerous applications in research, such as molecular spectroscopy, X ray diffraction by heavy proteins and X ray microlithography in LVSI circuit making [fr

  19. Hyperkalaemia after radiofrequency ablation of hepatocellular carcinoma

    NARCIS (Netherlands)

    Verhoevena, BH; Haagsma, EB; Appeltans, BMG; Slooff, MJH; de Jong, KP

    Radiofrequency ablation of liver tumours is a useful therapy for otherwise unresectable tumours. The complication rate is said to be low. In this case report we describe hyperkalaemia after radiofrequency ablation of a hepatocellular carcinoma in a patient with end-stage renal insufficiency. (C)

  20. Predicting nurses' acceptance of radiofrequency identification technology.

    Science.gov (United States)

    Norten, Adam

    2012-10-01

    The technology of radiofrequency identification allows for the scanning of radiofrequency identification-tagged objects and individuals without line-of-sight requirements. Healthcare organizations use radiofrequency identification to ensure the health and safety of patients and medical personnel and to uncover inefficiencies. Although the successful implementation of a system incorporating radiofrequency identification technologies requires acceptance and use of the technology, some nurses using radiofrequency identification in hospitals feel like "Big Brother" is watching them. This predictive study used a theoretical model assessing the effect of five independent variables: privacy concerns, attitudes, subjective norms, controllability, and self-efficacy, on a dependent variable, nurses' behavioral intention to use radiofrequency identification. A Web-based questionnaire containing previously validated questions was answered by 106 US RNs. Multiple linear regression showed that all constructs together accounted for 60% of the variance in nurses' intention to use radiofrequency identification. Of the predictors in the model, attitudes provided the largest unique contribution when the other predictors in the model were held constant; subjective norms also provided a unique contribution. Privacy concerns, controllability, and self-efficacy did not provide a significant contribution to nurses' behavioral intention to use radiofrequency identification.

  1. Temperature responsive porous silicon nanoparticles for cancer therapy - spatiotemporal triggering through infrared and radiofrequency electromagnetic heating.

    Science.gov (United States)

    Tamarov, Konstantin; Xu, Wujun; Osminkina, Liubov; Zinovyev, Sergey; Soininen, Pasi; Kudryavtsev, Andrey; Gongalsky, Maxim; Gaydarova, Azha; Närvänen, Ale; Timoshenko, Victor; Lehto, Vesa-Pekka

    2016-11-10

    One critical functionality of the carrier system utilized in targeted drug delivery is its ability to trigger the release of the therapeutic cargo once the carrier has reached its target. External triggering is an alluring approach as it can be applied in a precise spatiotemporal manner. In the present study, we achieved external triggering through the porous silicon (PSi) nanoparticles (NPs) by providing a pulse of infrared or radiofrequency radiation. The NPs were grafted with a temperature responsive polymer whose critical temperature was tailored to be slightly above 37°C. The polymer coating improved the biocompatibility of the NPs significantly in comparison with their uncoated counterparts. Radiation induced a rapid temperature rise, which resulted in the collapse of the polymer chains facilitating the cargo release. Both infrared and radiofrequency radiation were able to efficiently trigger the release of the encapsulated drug in vitro and induce significant cell death in comparison to the control groups. Radiofrequency radiation was found to be more efficient in vitro, and the treatment efficacy was verified in vivo in a lung carcinoma (3LL) mice model. After a single intratumoral administration of the carrier system combined with radiofrequency radiation, there was clear suppression of the growth of the carcinoma and a prolongation of the survival time of the animals. The temperature responsive (TR) polymer grafted on the surface of porous silicon nanoparticles (PSi NPs) changes its conformation in response to the heating induced by infrared or radiofrequency radiation. The conformation change allows the loaded doxorubicin to escape from the pores, achieving controlled drug release from TR PSi NPs, which displayed efficacy against malignant cells both in vitro and in vivo. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Top emitting white OLEDs

    Energy Technology Data Exchange (ETDEWEB)

    Freitag, Patricia; Luessem, Bjoern; Leo, Karl [Technische Universitaet Dresden, Institut fuer Angewandte Photophysik, George-Baehr-Strasse 1, 01069 Dresden (Germany)

    2009-07-01

    Top emitting organic light emitting diodes (TOLEDs) provide a number of interesting opportunities for new applications, such as the opportunity to fabricate ITO-free devices by using opaque substrates. This makes it possible to manufacture low cost OLEDs for signage and lighting applications. A general top emitting device consists of highly reflecting metal contacts as anode and semitransparent cathode, the latter one for better outcouling reasons. In between several organic materials are deposited as charge transporting, blocking, and emission layers. Here, we show a top emitting white organic light emitting diode with silver electrodes arranged in a p-i-n structure with p- and n-doped charge transport layers. The centrical emission layer consists of two phosphorescent (red and green) and one fluorescent (blue) emitter systems separated by an ambipolar interlayer to avoid mutual exciton quenching. By adding an additional dielectric capping layer on top of the device stack, we achieve a reduction of the strong microcavity effects which appear due to the high reflection of both metal electrodes. Therefore, the outcoupled light shows broad and nearly angle-independent emission spectra, which is essential for white light emitting diodes.

  3. Radiation

    International Nuclear Information System (INIS)

    2013-01-01

    The chapter one presents the composition of matter and atomic theory; matter structure; transitions; origin of radiation; radioactivity; nuclear radiation; interactions in decay processes; radiation produced by the interaction of radiation with matter

  4. 47 CFR 2.801 - Radiofrequency device defined.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Radiofrequency device defined. 2.801 Section 2... MATTERS; GENERAL RULES AND REGULATIONS Marketing of Radio-frequency Devices § 2.801 Radiofrequency device defined. As used in this part, a radiofrequency device is any device which in its operation is capable of...

  5. 21 CFR 882.4725 - Radiofrequency lesion probe.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiofrequency lesion probe. 882.4725 Section 882...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4725 Radiofrequency lesion probe. (a) Identification. A radiofrequency lesion probe is a device connected to a radiofrequency (RF...

  6. Pulsed radiofrequency microwave fields around a quadrupole particle accelerator: measurement and safety evaluation

    International Nuclear Information System (INIS)

    Sachdev, R.N.; Swarup, G.; Rajan, K.K.; Joseph, L.

    1996-01-01

    Pulsed radiofrequency microwave radiation (RFMR) fields occur during the use of high power microwaves in plasma heating in fusion research, plasma and solid state diagnostics, particle accelerators and colliders, pump sources in lasers, material processing as well as in high power radars. This paper describes the experimental work done at Trombay for measurement of pulsed RFMR fields in the working area of a radiofrequency quadrupole (RFQ) accelerator with the use of a meter calibrated in continuous field and interprets the observed fields in the light of existing protection criteria for pulsed RFMR fields. (author)

  7. A DSM-based “2.0” System for Human Intervention Planning and Scheduling in Facilities Emitting Ionizing Radiations

    CERN Document Server

    Baudin, M; De Jonghe, J

    2012-01-01

    To efficiently and safely plan, schedule and control its interventions in underground facilities, which are subject to ionizing radiations, CERN is currently developing a collaborative Web-based system. A similar project for maintenance management is also under way. On top of presenting their key requirements, this paper shows how the implementation of DSM can enhance a so-called Web 2.0 or collaborative dimension by bringing an intuitive and fair way of taking the dependencies between several activities into account. It is also discussed that the incoherencies brought in DSM by collaborative use (for instance regarding the time intervals) can be addressed by enlarging the binary DSM span of dependencies to ones of the Allen’s interval algebra or at least a subset of its dependencies.

  8. General Purpose Fortran Program for Discrete-Ordinate-Method Radiative Transfer in Scattering and Emitting Layered Media: An Update of DISORT

    Science.gov (United States)

    Tsay, Si-Chee; Stamnes, Knut; Wiscombe, Warren; Laszlo, Istvan; Einaudi, Franco (Technical Monitor)

    2000-01-01

    This update reports a state-of-the-art discrete ordinate algorithm for monochromatic unpolarized radiative transfer in non-isothermal, vertically inhomogeneous, but horizontally homogeneous media. The physical processes included are Planckian thermal emission, scattering with arbitrary phase function, absorption, and surface bidirectional reflection. The system may be driven by parallel or isotropic diffuse radiation incident at the top boundary, as well as by internal thermal sources and thermal emission from the boundaries. Radiances, fluxes, and mean intensities are returned at user-specified angles and levels. DISORT has enjoyed considerable popularity in the atmospheric science and other communities since its introduction in 1988. Several new DISORT features are described in this update: intensity correction algorithms designed to compensate for the 8-M forward-peak scaling and obtain accurate intensities even in low orders of approximation; a more general surface bidirectional reflection option; and an exponential-linear approximation of the Planck function allowing more accurate solutions in the presence of large temperature gradients. DISORT has been designed to be an exemplar of good scientific software as well as a program of intrinsic utility. An extraordinary effort has been made to make it numerically well-conditioned, error-resistant, and user-friendly, and to take advantage of robust existing software tools. A thorough test suite is provided to verify the program both against published results, and for consistency where there are no published results. This careful attention to software design has been just as important in DISORT's popularity as its powerful algorithmic content.

  9. Letter to the Editor. Comments on Karipidis, K. K., Henderson, A. S., Wijayasinghe, D., Tjong, L. and Tinker, R. Exposure to radiofrequency electromagnetic fields from WiFi in Australian schools. Radiat. Prot. Dosim. 1-8 (2017)

    International Nuclear Information System (INIS)

    Leach, Victor A.; Weller, Steven; Redmayne, Mary

    2017-01-01

    The measurement and collection of radiofrequency (RF) exposure data in Australian classrooms is important and ARPANSA should be applauded for undertaking the much-needed research reported in the above paper. However, the paper presented is very misleading and demonstrates how more care should have been taken when planning and designing the Wi-Fi survey. The survey results presented by Karipidis et al. are of little practical use and are misleading when it comes to determining what RF power density levels are realistically experienced by students in a 'typical' classroom setting. We would also like to highlight the opening sentence of the discussion section; the authors refer to this being a 'comprehensive' survey. We believe this claim is overstated as shown in this letter

  10. Cutaneous remodeling and photorejuvenation using radiofrequency devices

    Directory of Open Access Journals (Sweden)

    Elsaie Mohamed

    2009-01-01

    Full Text Available Radio frequency (RF is electromagnetic radiation in the frequency range of 3-300GHz. The primary effects of RF energy on living tissue are considered to be thermal. The goal of the new devices based on these frequency ranges is to heat specific layers of the skin. The directed use of RF can induce dermal heating and cause collagen degeneration. Wound healing mechanisms promote the remodeling of collagen and wound contraction, which ultimately clinically enhances the appearance of mild to moderate skin laxity. Preliminary studies have reported efficacy in the treatment of laxity that involves the periorbital area and jowls. Because RF energy is not dependent on specific chromophore interaction, epidermal melanin is not at risk of destruction and treatment of all skin types is possible. As such, radiofrequency-based systems have been used successfully for nonablative skin rejuvenation, atrophic scar revision and treatment of unwanted hair, vascular lesions and inflammatory acne. The use of RF is becoming more popular, although a misunderstanding exists regarding the mechanisms and limitations of its actions. This concise review serves as an introduction and guide to many aspects of RF in the non ablative rejuvenation of skin.

  11. Adaptive Response in Animals Exposed to Non-Ionizing Radiofrequency Fields: Some Underlying Mechanisms

    Directory of Open Access Journals (Sweden)

    Yi Cao

    2014-04-01

    Full Text Available During the last few years, our research group has been investigating the phenomenon of adaptive response in animals exposed to non-ionizing radiofrequency fields. The results from several separate studies indicated a significant increase in survival, decreases in genetic damage as well as oxidative damage and, alterations in several cellular processes in mice pre-exposed to radiofrequency fields and subsequently subjected to sub-lethal or lethal doses of γ-radiation or injected with bleomycin, a radiomimetic chemical mutagen. These observations indicated the induction of adaptive response providing the animals the ability to resist subsequent damage. Similar studies conducted by independent researchers in mice and rats have supported our observation on increased survival. In this paper, we have presented a brief review of all of our own and other independent investigations on radiofrequency fields-induced adaptive response and some underlying mechanisms discussed.

  12. COMAR technical information statement: expert reviews on potential health effects of radiofrequency electromagnetic fields and comments on the bioinitiative report.

    Science.gov (United States)

    2009-10-01

    The Committee on Man and Radiation (COMAR) is a technical committee of the Engineering in Medicine and Biology Society (EMBS) of the Institute of Electrical and Electronics Engineers (IEEE). Its primary area of interest is biological effects of non-ionizing electromagnetic radiation, including radiofrequency (RF) energy. The public interest in possible health effects attributed to RF energy, such as emitted by mobile phones, wireless telephone base stations, TV and radio broadcasting facilities, Wi-Fi systems and many other sources, has been accompanied by commentary in the media that varies considerably in reliability and usefulness for their audience. The focus of this COMAR Technical Information Statement is to identify quality sources of scientific information on potential health risks from exposure to RF energy. This Statement provides readers with references to expert reports and other reliable sources of information about this topic, most of which are available on the Internet. This report summarizes the conclusions from several major reports and comments on the markedly different conclusions in the BioInitiative Report (abbreviated BIR below). Since appearing on the Internet in August 2007, the BIR has received much media attention but, more recently, has been criticized by several health organizations (see Section titled "Views of health agencies about BIR"). COMAR concludes that the weight of scientific evidence in the RF bioeffects literature does not support the safety limits recommended by the BioInitiative group. For this reason, COMAR recommends that public health officials continue to base their policies on RF safety limits recommended by established and sanctioned international organizations such as the Institute of Electrical and Electronics Engineers International Committee on Electromagnetic Safety and the International Commission on Non-Ionizing Radiation Protection, which is formally related to the World Health Organization.

  13. Infrared Radiation and Blackbody Radiation

    OpenAIRE

    2005-01-01

    tut present graph Tutorial Presentation Graph Interactive Media Element This interactive tutorial covers the following: How infrared radiation was discovered., The regions of infrared radiation and their relations to temperature., The nature of blackbody radiation and Planck's radiation law., The relationship between temperature and the power emitted by radiation.The interactions in this tutorial include clicking to reveal new information, and questions that help students...

  14. Visible optical radiation generates bactericidal effect applicable for inactivation of health care associated germs demonstrated by inactivation of E. coli and B. subtilis using 405-nm and 460-nm light emitting diodes

    Science.gov (United States)

    Hönes, Katharina; Stangl, Felix; Sift, Michael; Hessling, Martin

    2015-07-01

    The Ulm University of Applied Sciences is investigating a technique using visible optical radiation (405 nm and 460 nm) to inactivate health-hazardous bacteria in water. A conceivable application could be point-of-use disinfection implementations in developing countries for safe drinking water supply. Another possible application field could be to provide sterile water in medical institutions like hospitals or dental surgeries where contaminated pipework or long-term disuse often results in higher germ concentrations. Optical radiation for disinfection is presently mostly used in UV wavelength ranges but the possibility of bacterial inactivation with visible light was so far generally disregarded. One of the advantages of visible light is, that instead of mercury arc lamps, light emitting diodes could be used, which are commercially available and therefore cost-efficient concerning the visible light spectrum. Furthermore they inherit a considerable longer life span than UV-C LEDs and are non-hazardous in contrast to mercury arc lamps. Above all there are specific germs, like Bacillus subtilis, which show an inactivation resistance to UV-C wavelengths. Due to the totally different deactivation mechanism even higher disinfection rates are reached, compared to Escherichia coli as a standard laboratory germ. By 460 nm a reduction of three log-levels appeared with Bacillus subtilis and a half log-level with Escherichia coli both at a dose of about 300 J/cm². By the more efficient wavelength of 405 nm four and a half log-levels are reached with Bacillus subtilis and one and a half log-level with Escherichia coli also both at a dose of about 300 J/cm². In addition the employed optical setup, which delivered a homogeneous illumination and skirts the need of a stirring technique to compensate irregularities, was an important improvement compared to previous published setups. Evaluated by optical simulation in ZEMAX® the designed optical element provided proven

  15. [Radiofrequency ablation of hepatocellular carcinoma].

    Science.gov (United States)

    Widmann, Gerlig; Schullian, Peter; Bale, Reto

    2013-03-01

    Percutaneous radiofrequency ablation (RFA) is well established in the treatment of hepatocellular carcinoma (HCC). Due to its curative potential, it is the method of choice for non resectable BCLC (Barcelona Liver Clinic) 0 and A. RFA challenges surgical resection for small HCC and is the method of choice in bridging for transplantation and recurrence after resection or transplantation. The technical feasibility of RFA depends on the size and location of the HCC and the availability of ablation techniques (one needle techniques, multi-needle techniques). More recently, stereotactic multi-needle techniques with 3D trajectory planning and guided needle placement substantially improve the spectrum of treatable lesions including large volume tumors. Treatment success depends on the realization of ablations with large intentional margins of tumor free tissue (A0 ablation in analogy to R0 resection), which has to be documented by fusion of post- with pre-ablation images, and confirmed during follow-up imaging.

  16. Light-Emitting Pickles

    Science.gov (United States)

    Vollmer, M.; Mollmann, K-P.

    2015-01-01

    We present experiments giving new insights into the classical light-emitting pickle experiment. In particular, measurements of the spectra and temperatures, as well as high-speed recordings, reveal that light emission is connected to the polarity of the electrodes and the presence of hydrogen.

  17. Synchrotron radiation and its various uses in physics, chemistry and biology

    Energy Technology Data Exchange (ETDEWEB)

    Farge, Y [Laboratoire pour l' Utilisation du Rayonnement Electromagnetique (LURE), Paris-11 Univ., 91 - Orsay (France)

    1975-01-01

    The synchrotron radiation emitted by synchrotrons or storage rings has exceptional properties: spectral continuity from X-rays to radiofrequencies, high intensity, focussed emission in the orbit plane, polarization, and time pulsed structure. The radiation is a unique tool for spectroscopic investigations in the far uv or X-rays on atoms, molecules, or solids. Time resolved spectroscopy in the nano and subnanosecond range is now available in a very broad wavelength range. In the X-ray range, these sources are revolutionary because they are more powerful than the best X-ray tubes by two to four orders of magnitude; it will be very soon possible to do kinetic measurements with typical times of one second and less either by diffraction, scattering, or topography.

  18. The synchrotron radiation and its various uses in physics, chemistry and biology

    International Nuclear Information System (INIS)

    Farge, Y.

    1975-01-01

    The synchrotron radiation emitted by synchrotrons or storage rings has exceptional properties: spectral continuity from X-rays to radiofrequencies, high intensity, focussed emission in the orbit plane, polarization, time pulsed structure. For the sake of these properties, this radiation is a unique tool for spectroscopic investigations in the far UV or X-rays on atoms, molecules or solids. Time resolved spectroscopy in the nano and subnanosecond range is now available in a very broad wavelength range. In the X-ray range, these sources are introducing a revolution because they are more powerfull than the best X-ray tubes by two to four orders of magnitude; it will be very soon possible to do kinetic measurements with typical times of one second and less either by diffraction, scattering or topography [fr

  19. Safety of light emitting diodes in toys.

    Science.gov (United States)

    Higlett, M P; O'Hagan, J B; Khazova, M

    2012-03-01

    Light emitting diodes (LEDs) are increasingly being used in toys. An assessment methodology is described for determining the accessible emission limits for the optical radiation from the toys, which takes account of expected use and reasonably foreseeable misuse of toys. Where data are available, it may be possible to assess the toy from the data sheet alone. If this information is not available, a simple measurement protocol is proposed.

  20. Safety of light emitting diodes in toys

    International Nuclear Information System (INIS)

    Higlett, M P; O'Hagan, J B; Khazova, M

    2012-01-01

    Light emitting diodes (LEDs) are increasingly being used in toys. An assessment methodology is described for determining the accessible emission limits for the optical radiation from the toys, which takes account of expected use and reasonably foreseeable misuse of toys. Where data are available, it may be possible to assess the toy from the data sheet alone. If this information is not available, a simple measurement protocol is proposed.

  1. Assessment of DNA sensitivity in peripheral blood leukocytes after occupational exposure to microwave radiation: the alkaline comet assay and chromatid breakage assay

    International Nuclear Information System (INIS)

    Garaj-Vrhovac, V.; Kopjar, N.

    2002-01-01

    The people of industrialised societies are continuously exposed to increasing levels of electromagnetic fields (EMF) emitted by various electrical installations and telecommunication systems. In recent years there has been growing interest in the health effects of the electromagnetic radiation's designated extremely low frequency (ELF) and radiofrequency radiation (RFR). It is known that exposure to microwave radiation has different biological effects on eye, the nervous system and its function, circulatory and the reproductive system. Available data on cytogenetic consequences of microwave exposure on the induction of chromosome damage are sometimes contradictory, mostly because of different experimental conditions of in vitro and in vivo studies. However, in occupationally exposed persons elevated levels of DNA damage as expressed by means of cytogenetic endpoints were observed. Positive results in induction of micronuclei are also reported after in vitro exposure to microwave radiation on human lymphocytes. It has been suggested that exposure to radiofrequency radiation may have genetic effects which predispose to the development of cancer, particularly lymphoma and leukaemia, and also birth defects such as Down's syndrome

  2. Exposure to non-ionizing electromagnetic fields emitted from mobile phones induced DNA damage in human ear canal hair follicle cells.

    Science.gov (United States)

    Akdag, Mehmet; Dasdag, Suleyman; Canturk, Fazile; Akdag, Mehmet Zulkuf

    2018-01-01

    The aim of this study was to investigate effect of radiofrequency radiation (RFR) emitted from mobile phones on DNA damage in follicle cells of hair in the ear canal. The study was carried out on 56 men (age range: 30-60 years old)in four treatment groups with n = 14 in each group. The groups were defined as follows: people who did not use a mobile phone (Control), people use mobile phones for 0-30 min/day (second group), people use mobile phones for 30-60 min/day (third group) and people use mobile phones for more than 60 min/day (fourth group). Ear canal hair follicle cells taken from the subjects were analyzed by the Comet Assay to determine DNA damages. The Comet Assay parameters measured were head length, tail length, comet length, percentage of head DNA, tail DNA percentage, tail moment, and Olive tail moment. Results of the study showed that DNA damage indicators were higher in the RFR exposure groups than in the control subjects. In addition, DNA damage increased with the daily duration of exposure. In conclusion, RFR emitted from mobile phones has a potential to produce DNA damage in follicle cells of hair in the ear canal. Therefore, mobile phone users have to pay more attention when using wireless phones.

  3. Public Health Ministere stablish that all medical equipment records request who emit ionizing radiations providing health organizations, Public or privates, such as enterprise who trade medical products, have to be carry out between of the Public a Health Ministere Technology Department and DINATEN of the Industry energy and Mining Ministere

    International Nuclear Information System (INIS)

    2004-01-01

    The present decree stablish that the evaluation of all the applications of registration of medical teams that emit ionizing radiations, coming from the institutions of health, you publish or private, as well as companies that market medical products will be carried out among the Department of Technology it Prescribes of the Ministry of Health it Public and the DINATEN of the Ministry of Industry Energy and Mining

  4. Comparison of the heat shock response induced by conventional heating and two methods of delivery of pulsed radiofrequency energy

    International Nuclear Information System (INIS)

    Laurence, J.A.; University of Sydney, NSW; McKenzie, D.R.; Veas, L.; French, P.W.

    2002-01-01

    Full text: In 2001, we published a (hypothetical) mechanism by which radiofrequency (RF) radiation from mobile phones could induce cancer, via the chronic induction of the heat shock response (HSR). This hypothesis provides the focus for our research. Other groups have reported induction of the HSR by RF at apparently non thermal levels. The aim of this study was to determine whether the HSR induced by RF is (a) truly non thermal and (b) quantitatively or qualitatively different from that induced by conventional heating of cells. A rat mast cell line, RBL-2H3, was chosen as the target RBL-2H3 cells were exposed in an air incubator at 41.1 deg C for 45 minutes and 75 minutes, and then returned to a 37 deg C incubator. Sham exposures were performed in the same air incubator at 37 deg C. Cells were exposed for 1 hour in the two pulsed RF exposure systems. The first was a converted 750W microwave oven that emits a short burst of 2.45GHz pulses at the start of each contiguous six minute period. This exposes cells to an average specific energy absorption rate (SAR) of 20W/kg. The second system was a TEM cell, which simulates. GSM pulses - the earner frequency is 0.9GHz pulse modulated at 217Hz. The SAR was approx 0.1W/kg. Both of these exposure systems are housed in incubators maintained at 37 deg C. Sham exposures were performed in the two systems with the same conditions but with no RF radiation present. Cell samples for the conventional heating and microwave exposures were taken 0, 2. 5, 5 and 20 hours after exposure, and expression of heat shock proteins hsp 110, 90, 70, 60 and 56 were determined by Western Blotting and compared between exposures

  5. Top-emitting organic light-emitting diodes.

    Science.gov (United States)

    Hofmann, Simone; Thomschke, Michael; Lüssem, Björn; Leo, Karl

    2011-11-07

    We review top-emitting organic light-emitting diodes (OLEDs), which are beneficial for lighting and display applications, where non-transparent substrates are used. The optical effects of the microcavity structure as well as the loss mechanisms are discussed. Outcoupling techniques and the work on white top-emitting OLEDs are summarized. We discuss the power dissipation spectra for a monochrome and a white top-emitting OLED and give quantitative reports on the loss channels. Furthermore, the development of inverted top-emitting OLEDs is described.

  6. Examples of Radiation-Emitting Products

    Science.gov (United States)

    ... Ultrasonography • Doppler ultrasound • Color doppler ultrasound • Hyperthermia • Diathermy/physical therapy • Bone healing • Lithotripsy • Phacoemulsifier • Needle guide • Bone density measuring • Geriatric bath (ultrasound) • Hearing aid • Many scientific uses • Nondestructive ...

  7. New resonant circuits for the ISOLTRAP radiofrequency quadrupole trap

    CERN Document Server

    SENECAL, Pierre

    2015-01-01

    This report describes my work during my Summer Student Program. My main project was building and testing a resonance-circuit box for a radio-frequency power supply used with the radio-frequency cooler and buncher.

  8. Dielectric-filled radiofrequency linacs

    Energy Technology Data Exchange (ETDEWEB)

    Faehl, R J; Keinigs, R K; Pogue, E W [Los Alamos National Lab., NM (United States)

    1997-12-31

    High current, high brightness electron beam accelerators promise to open up dramatic new applications. Linear induction accelerators are currently viewed as the appropriate technology for these applications. A concept by Humphries and Hwang may permit radiofrequency accelerators to fulfill the same functions with greater simplicity and enhanced flexibility. This concept involves the replacement of vacuum rf cavities with dielectric filled ones. Simple analysis indicates that the resonant frequencies are reduced by a factor of ({epsilon}{sub 0}/{epsilon}){sup 1/2} while the stored energy is increased by {epsilon}/{epsilon}{sub 0}. For a high dielectric constant like water, this factor can approach 80. A series of numerical calculations of simple pill-box cavities was performed. Eigenfunctions and resonant frequencies for a full system configuration, including dielectric material, vacuum beamline, and a ceramic window separating the two have been computed. These calculations are compared with the results of a small experimental cavity which have been constructed and operated. Low power tests show excellent agreement. (author). 4 figs., 8 refs.

  9. The radiofrequency magnetic dipole discharge

    Energy Technology Data Exchange (ETDEWEB)

    Martines, E., E-mail: emilio.martines@igi.cnr.it; Zuin, M.; Cavazzana, R.; Fassina, A.; Spolaore, M. [Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete SpA), Corso Stati Uniti 4, 35127 Padova (Italy); Marcante, M. [Dipartimento di Fisica, Università di Trento, via Sommarive 14, 38123 Povo, TN (Italy); TIFPA, Trento Institute for Fundamental Physics and Applications INFN, 38123 Trento (Italy)

    2016-05-15

    This paper describes a novel and simple concept of plasma source, which is able to produce a radiofrequency magnetized discharge with minimal power requirements. The source is based on the magnetron concept and uses a permanent magnet as an active electrode. The dipolar field produced by the magnet confines the electrons, which cause further ionization, thus producing a toroidally shaped plasma in the equatorial region around the electrode. A plasma can be ignited with such scheme with power levels as low as 5 W. Paschen curves have been built for four different working gases, showing that in Helium or Neon, plasma breakdown is easily obtained also at atmospheric pressure. The plasma properties have been measured using a balanced Langmuir probe, showing that the electron temperature is around 3–4 eV and higher in the cathode proximity. Plasma densities of the order of 10{sup 16 }m{sup −3} have been obtained, with a good positive scaling with applied power. Overall, the electron pressure appears to be strongly correlated with the magnetic field magnitude in the measurement point.

  10. The radiofrequency magnetic dipole discharge

    Science.gov (United States)

    Martines, E.; Zuin, M.; Marcante, M.; Cavazzana, R.; Fassina, A.; Spolaore, M.

    2016-05-01

    This paper describes a novel and simple concept of plasma source, which is able to produce a radiofrequency magnetized discharge with minimal power requirements. The source is based on the magnetron concept and uses a permanent magnet as an active electrode. The dipolar field produced by the magnet confines the electrons, which cause further ionization, thus producing a toroidally shaped plasma in the equatorial region around the electrode. A plasma can be ignited with such scheme with power levels as low as 5 W. Paschen curves have been built for four different working gases, showing that in Helium or Neon, plasma breakdown is easily obtained also at atmospheric pressure. The plasma properties have been measured using a balanced Langmuir probe, showing that the electron temperature is around 3-4 eV and higher in the cathode proximity. Plasma densities of the order of 1016 m-3 have been obtained, with a good positive scaling with applied power. Overall, the electron pressure appears to be strongly correlated with the magnetic field magnitude in the measurement point.

  11. Ablation of liver metastases by radiofrequency

    International Nuclear Information System (INIS)

    Baere, T. de

    2012-01-01

    Radiofrequency is a thermal ablative technique that is most often used percuteanously under image guidance. Thermal damage is obtained through frictional heating of a high frequency current. The maximal volume of destruction obtained in one radiofrequency delivery is around 4 cm and consequently, best indication for treatment are tumours below 3 cm. When compared, radiofrequency and surgical removal for tumours below 25 mm in diameter demonstrated a rate of incomplete resection/ablation of 6% and 7.3% respectively. Median survival after the first radiofrequency of a liver metastasis of CRC is reported to be 24 to 52 months with a 5 years overall survival of 18 to 44%. The median overall survival increases from 22 to 48 months depending on the use of radiofrequency ablation as rescue treatment after failure of others, or as a first line treatment. For patients with a single tumour, less than 4 cm, the survival rates at 1, 3, and 5 years are respectively 97%, 84% and 40%, with a median survival of 50 months. Follow-up imaging requires to use contrast-enhanced CT or MRI, looking for local recurrences evidenced by local foci of enhancement at the periphery of the ablation zone. (author)

  12. A survey on monopolar radiofrequency treatment.

    Science.gov (United States)

    Suh, Dong Hye; Hong, Eun Sun; Kim, Hyun Joo; Lee, Sang Jun; Kim, Hei Sung

    2017-09-01

    This questionnaire-based study was aimed to measure the level of appreciation, awareness of the special tips, and practice patterns of monopolar radiofrequency among Korean dermatologists practicing a specific monopolar radiofrequency device (Thermage® Inc., Hayward, CA). A total of 82 surveys were analyzed to show that the majority of participants (78.8%) were highly satisfied with the outcomes of monopolar radiofrequency treatment. All respondents were aware of the Eye Tip 0.25 cm 2 , and the majority knew the difference between the Face tip (blue) and the Total tip (orange). Most (86.3%) agreed to the statement that 900 shots were appropriate for facial tightening in those between the ages of 35 and 65 years. 66.2% of participants reported to have perform monopolar radiofrequency to extra-facial sites within the past year. As for the tips, the Total tip was most popular for all body sties and the Big tip was favored for the abdomen, thighs and buttock. We hope our data allow dermatologists to better utilize monopolar radiofrequency. © 2017 Wiley Periodicals, Inc.

  13. 21 CFR 882.4400 - Radiofrequency lesion generator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiofrequency lesion generator. 882.4400 Section... (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4400 Radiofrequency lesion generator. (a) Identification. A radiofrequency lesion generator is a device used to produce...

  14. 21 CFR 886.4100 - Radiofrequency electrosurgical cautery apparatus.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiofrequency electrosurgical cautery apparatus... SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4100 Radiofrequency electrosurgical cautery apparatus. (a) Identification. A radiofrequency electrosurgical cautery apparatus is an AC...

  15. Anthropogenic radiofrequency electromagnetic fields as an emerging threat to wildlife orientation.

    Science.gov (United States)

    Balmori, Alfonso

    2015-06-15

    The rate of scientific activity regarding the effects of anthropogenic electromagnetic radiation in the radiofrequency (RF) range on animals and plants has been small despite the fact that this topic is relevant to the fields of experimental biology, ecology and conservation due to its remarkable expansion over the past 20 years. Current evidence indicates that exposure at levels that are found in the environment (in urban areas and near base stations) may particularly alter the receptor organs to orient in the magnetic field of the earth. These results could have important implications for migratory birds and insects, especially in urban areas, but could also apply to birds and insects in natural and protected areas where there are powerful base station emitters of radiofrequencies. Therefore, more research on the effects of electromagnetic radiation in nature is needed to investigate this emerging threat. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Annual report of the Chief Executive Officer of Australian Radiation Protection And Nuclear Safety Agency, 2001-200

    International Nuclear Information System (INIS)

    2002-01-01

    In the period analysed ARPANSA contributed to the (then) Health and Aged Care portfolio's 'Outcome 1: Population Health and Safety'. The objective of this outcome was the promotion and protection of the health of all Australians and minimising the incidence of preventable mortality, illness, injury and disability. The main outcomes, as outlined in the reports are: regulation of Commonwealth activities involving radiation sources and nuclear facilities; progress towards the development of a National Directory for Radiation Protection; quality assurance programs in medical radiation and conduct evaluations of individual and population doses; health impact assessment of radiation exposure and methodologies for this assessment, recommendations and guidelines for limiting radiation exposure; progress towards third-party quality assurance certification for the personal radiation monitoring service, radionuclide analysis of gamma ray emitting nuclides, Ultraviolet Protection Factor; assessing radiopharmaceutical testing and the protection dosimeter calibration service; maintenance of a network for monitoring radionuclides in the atmosphere; safety standards and guidance in support of the work of the Radiation Health and Safety Advisory Council, the Radiation Health Committee and the Nuclear Safety Committee. The major priorities for ARPANSA in the reporting year, included the assessment of an application to construct the replacement research reactor at ANSTO, implementation of a process for public consultation and participation in the licensing of nuclear facilities and the development of national standards and codes of practice, including a standard for radiofrequency radiation

  17. Radiofrequency-thermoablation in malignant liver disease

    International Nuclear Information System (INIS)

    Pichler, L.; Anzboeck, W.; Paertan, G.; Hruby, W.

    2002-01-01

    The clinical application of radiofrequency tumor ablation in primary liver tumors and metastatic liver disease is rapidly growing because this technique has proven to be simple, safe, and effective in first clinical studies. Most of the patients with malignant liver disease are not candidates for surgical resection due localisation or comorbidity, so radiofrequency therapy offers a good alternative for inoperable patients. With this method, high frequency alternating current is delivered to tissue via a needle electrode, the produced heat leads to coagulation necrosis. The largest focus of necrosis that can be induced with the currently available systems is approximately 4-5 cm with a single application. The radiofrequency needle is usually placed with US or CT guidance. For follow up examinations CT and MRI can be used, they proved to be equally accurate in the assessment of treatment response. (orig.) [de

  18. Power output and efficiency of beta-emitting microspheres

    International Nuclear Information System (INIS)

    Cheneler, David; Ward, Michael

    2015-01-01

    Current standard methods to calculate the dose of radiation emitted during medical applications by beta-minus emitting microspheres rely on an over-simplistic formalism. This formalism is a function of the average activity of the radioisotope used and the physiological dimensions of the patient only. It neglects the variation in energy of the emitted beta particle due to self-attenuation, or self-absorption, effects related to the finite size of the sphere. Here it is assumed the sphere is comprised of a pure radioisotope with beta particles being emitted isotropically throughout the material. The full initial possible kinetic energy distribution of a beta particle is taken into account as well as the energy losses due to scattering by other atoms in the microsphere and bremsstrahlung radiation. By combining Longmire’s theory of the mean forward range of charged particles and the Rayleigh distribution to take into account the statistical nature of scattering and energy straggling, the linear attenuation, or self-absorption, coefficient for beta-emitting radioisotopes has been deduced. By analogy with gamma radiation transport in spheres, this result was used to calculate the rate of energy emitted by a beta-emitting microsphere and its efficiency. Comparisons to standard point dose kernel formulations generated using Monte Carlo data show the efficacy of the proposed method. Yttrium-90 is used as a specific example throughout, as a medically significant radioisotope, frequently used in radiation therapy for treating cancer. - Highlights: • Range-energy relationship for the beta particles in yttrium-90 is calculated. • Formalism for the semi-analytical calculation of self-absorption coefficients. • Energy-dependent self-absorption coefficient calculated for yttrium-90. • Flux rate of beta particles from a self-attenuating radioactive sphere is shown. • The efficiency of beta particle emitting radioactive microspheres is calculated

  19. Statistical analysis of electromagnetic radiation measurements in the vicinity of indoor microcell GSM/UMTS base stations in Serbia.

    Science.gov (United States)

    Koprivica, Mladen; Petrić, Majda; Nešković, Nataša; Nešković, Aleksandar

    2016-01-01

    To determine the level of radiofrequency radiation generated by base stations of Global System for Mobile Communications and Universal Mobile Telecommunication System, extensive electromagnetic field strength measurements were carried out in the vicinity of 664 base station locations. These were classified into three categories: indoor, masts, and locations with installations on buildings. Although microcell base stations with antennas installed indoors typically emit less power than outdoor macrocell base stations, the fact that people can be found close to antennas requires exposure originating from these base stations to be carefully considered. Measurement results showed that maximum recorded value of electric field strength exceeded International Commission on Non-Ionizing Radiation Protection reference levels at 7% of indoor base station locations. At the same time, this percentage was much lower in the case of masts and installations on buildings (0% and 2.5%, respectively). © 2015 Wiley Periodicals, Inc.

  20. Radio-frequency integrated-circuit engineering

    CERN Document Server

    Nguyen, Cam

    2015-01-01

    Radio-Frequency Integrated-Circuit Engineering addresses the theory, analysis and design of passive and active RFIC's using Si-based CMOS and Bi-CMOS technologies, and other non-silicon based technologies. The materials covered are self-contained and presented in such detail that allows readers with only undergraduate electrical engineering knowledge in EM, RF, and circuits to understand and design RFICs. Organized into sixteen chapters, blending analog and microwave engineering, Radio-Frequency Integrated-Circuit Engineering emphasizes the microwave engineering approach for RFICs. Provide

  1. Project 8: Update on a radiofrequency tritium spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Monreal, B. [University of California, Santa Barbara (United States)

    2012-09-28

    We describe a novel technique for measuring the energies of beta decay electrons. The technique relies on the detection of coherent radiation emitted by an electron in a cyclotron orbit in a strong magnetic field. Since the frequency of cyclotron orbit depends on the particle Lorentz boost, the detection and measurement of the coherent radiation emitted is tantamount to measuring the kinetic energy of the electron. As the technique inherently involves a nondestructive frequency measurement, it can in principle achieve a high resolution and accuracy. A new experimental effort, known as Project 8, will apply this technique to a sensitive measurement of the beta endpoint of tritium, which is sensitive to the absolute mass scale of the neutrino. In this paper we describe experimental progress towards demonstrating the Project 8 technique, and present the configuration of a pilot experiment.

  2. The radiofrequency frontier: a review of radiofrequency and combined radiofrequency pulsed-light technology in aesthetic medicine.

    Science.gov (United States)

    Sadick, Neil; Sorhaindo, Lian

    2005-05-01

    Radiofrequency (RF) and combined RF light source technologies have established themselves as safe and effective treatment modalities for several dermatologic procedures, including skin tightening, hair and leg vein removal, acne scarring, skin rejuvenation, and wrinkle reduction. This article reviews the technology, clinical applications, and recent advances of RF and combined RF light/laser source technologies in aesthetic medicine.

  3. Radiofrequency protection guidelines and standards: basic concepts and principles

    International Nuclear Information System (INIS)

    Czerski, P.

    1985-01-01

    Over the past quarter of a century, radiofrequency radiation protection guidelines and standards evolved gradually and are continuously revised and refined. The scientific rationales presented for proposed exposure limits are achieving a considerable scientific sophistication. With increasing scientific validity of the presented arguments, the values of exposure limits are converging and one may hope that they will become convincing and acceptable to all schools of thought. Still more research is needed to refine the available exposure limits. This is recognized by ANSI who revise their recommendations periodically and are now engaged in the preparation of the next revision. INIRC/IRPA is also reconsidering their interim guideline. The Australian Standards Association also stressed the temporary nature of their exposure limits

  4. Percutaneous Radiofrequency Ablation for Treatment of Recurrent Retroperitoneal Liposarcoma

    International Nuclear Information System (INIS)

    Keil, Sebastian; Bruners, Philipp; Brehmer, Bernhard; Mahnken, Andreas Horst

    2008-01-01

    Percutaneous CT-guided radiofrequency ablation (RFA) is becoming more and more established in the treatment of various neoplasms, including retroperitoneal tumors of the kidneys and the adrenal glands. We report the case of RFA in a patient suffering from the third relapse of a retroperitoneal liposarcoma in the left psoas muscle. After repeated surgical resection and supportive radiation therapy of a primary retroperitoneal liposarcoma and two surgically treated recurrences, including replacement of the ureter by a fraction of the ileum, there was no option for further surgery. Thus, we considered RFA as the most suitable treatment option. Monopolar RFA was performed in a single session with a 2-cm umbrella-shaped LeVeen probe. During a 27-month follow-up period the patient remained free of tumor.

  5. Auger Emitting Radiopharmaceuticals for Cancer Therapy

    Science.gov (United States)

    Falzone, Nadia; Cornelissen, Bart; Vallis, Katherine A.

    Radionuclides that emit Auger electrons have been of particular interest as therapeutic agents. This is primarily due to the short range in tissue, controlled linear paths and high linear energy transfer of these particles. Taking into consideration that ionizations are clustered within several cubic nanometers around the point of decay the possibility of incorporating an Auger emitter in close proximity to the cancer cell DNA has immense therapeutic potential thus making nuclear targeted Auger-electron emitters ideal for precise targeting of cancer cells. Furthermore, many Auger-electron emitters also emit γ-radiation, this property makes Auger emitting radionuclides a very attractive option as therapeutic and diagnostic agents in the molecular imaging and management of tumors. The first requirement for the delivery of Auger emitting nuclides is the definition of suitable tumor-selective delivery vehicles to avoid normal tissue toxicity. One of the main challenges of targeted radionuclide therapy remains in matching the physical and chemical characteristics of the radionuclide and targeting moiety with the clinical character of the tumor. Molecules and molecular targets that have been used in the past can be classified according to the carrier molecule used to deliver the Auger-electron-emitting radionuclide. These include (1) antibodies, (2) peptides, (3) small molecules, (4) oligonucleotides and peptide nucleic acids (PNAs), (5) proteins, and (6) nanoparticles. The efficacy of targeted radionuclide therapy depends greatly on the ability to increase intranuclear incorporation of the radiopharmaceutical without compromising toxicity. Several strategies to achieve this goal have been proposed in literature. The possibility of transferring tumor therapy based on the emission of Auger electrons from experimental models to patients has vast therapeutic potential, and remains a field of intense research.

  6. Hawking radiation

    Science.gov (United States)

    Parentani, Renaud; Spindel, Philippe

    2011-12-01

    Hawking radiation is the thermal radiation predicted to be spontaneously emitted by black holes. It arises from the steady conversion of quantum vacuum fluctuations into pairs of particles, one of which escaping at infinity while the other is trapped inside the black hole horizon. It is named after the physicist Stephen Hawking who derived its existence in 1974. This radiation reduces the mass of black holes and is therefore also known as black hole evaporation.

  7. Radiofrequency exposure on fast patrol boats in the Royal Norwegian Navy--an approach to a dose assessment.

    Science.gov (United States)

    Baste, Valborg; Mild, Kjell Hansson; Moen, Bente E

    2010-07-01

    Epidemiological studies related to radiofrequency (RF) electromagnetic fields (EMF) have mainly used crude proxies for exposure, such as job titles, distance to, or use of different equipment emitting RF EMF. The Royal Norwegian Navy (RNoN) has measured RF field emitted from high-frequency antennas and radars on several spots where the crew would most likely be located aboard fast patrol boats (FPB). These boats are small, with short distance between the crew and the equipment emitting RF field. We have described the measured RF exposure aboard FPB and suggested different methods for calculations of total exposure and annual dose. Linear and spatial average in addition to percentage of ICNIRP and squared deviation of ICNIRP has been used. The methods will form the basis of a job exposure matrix where relative differences in exposure between groups of crew members can be used in further epidemiological studies of reproductive health. 2010 Wiley-Liss, Inc.

  8. Modes of oscillation in radiofrequency Paul traps

    DEFF Research Database (Denmark)

    Landa, H.; Reznik, B.; Drewsen, M.

    2012-01-01

    We examine the time-dependent dynamics of ion crystals in radiofrequency traps. The problem of stable trapping of general threedimensional crystals is considered and the validity of the pseudopotential approximation is discussed. We analytically derive the micromotion amplitude of the ions...

  9. Pulsed Radiofrequency Ablation for Treating Sural Neuralgia.

    Science.gov (United States)

    Abd-Elsayed, Alaa; Jackson, Markus; Plovanich, Elizabeth

    2018-01-01

    Sural neuralgia is persistent pain in the distribution of the sural nerve that provides sensation to the lateral posterior corner of the leg, lateral foot, and fifth toe. Sural neuralgia is a rare condition but can be challenging to treat and can cause significant limitation. We present 2 cases of sural neuralgia resistant to conservative management that were effectively treated by pulsed radiofrequency ablation. A 65-year-old female developed sural neuralgia after a foot surgery and failed conservative management. She had successful sural nerve blocks, and pulsed radiofrequency ablation led to an 80% improvement in her pain. A 33-year-old female presented with sural neuralgia secondary to two falls. The patient had tried several conservative modalities with no success. We performed diagnostic blocks and pulsed radiofrequency ablation, and the patient reported 80% improvement in her pain. Pulsed radiofrequency ablation may be a safe and effective treatment for patients with sural neuralgia that does not respond to conservative therapy. However, studies are needed to elucidate its effectiveness and safety profile.

  10. Radiofrequency and microwave interactions between biomolecular systems

    Czech Academy of Sciences Publication Activity Database

    Kučera, Ondřej; Cifra, Michal

    2016-01-01

    Roč. 42, č. 1 (2016), s. 1-8 ISSN 0092-0606 R&D Projects: GA ČR(CZ) GA15-17102S Institutional support: RVO:67985882 Keywords : Cell signaling * Radiofrequency * Bioelectrodynamics Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.241, year: 2016

  11. Management of trigeminal neuralgia by radiofrequency ...

    African Journals Online (AJOL)

    The outcome depends on the type of TN with best results with classical idiopathic type. Also better results occurred with isolated V3 affection. The radiofrequency thermocoagulation of trigeminal nerve is a low risk, highly effective and minimally invasive procedure that should be started with in all cases of TN.

  12. Radiofrequency catheter oblation in atrial flutter

    International Nuclear Information System (INIS)

    Yan Ji; Wang Heping; Xu Jian; Liu Fuyuan; Fan Xizhen; An Chunsheng; Han Xiaoping; Ding Xiaomei; Wang Jiasheng; Gu Tongyuan

    2002-01-01

    Objective: To evaluate the radiofrequency catheter ablation for type I atrial flutter through application of Holo catheter labelling with anatomic imaging localization to ablate the isthmus of IVCTA during complete double-way block. Methods: Eleven cases with type I atrial flutter undergone Holo catheter labelling technique and consecution with conduction time change of coronary venous sinus orifice with-right atrial lower lateral wall pace excitation, were performed with radiofrequency catheter ablation for the isthmus outcoming with complete double-way conduction block. Results: All together 11 cases with 4 of atrial flutter and 7 of sinus rhythm were undergone radiofrequency catheter ablation resulting with double-way conduction block of the isthmus accompanied by prolongation of right atrial conduction time 56.0 ± 2.3 ms and 53.0 ± 4.6 ms respectively. The right atrial excitation appeared to be in clockwise and counter-clockwise of single direction. No recurrence occurred during 3-34 months follow up with only one showing atrial fibrillation. Conclusions: The application of Holo catheter labelling technique with anatomic imaging localization to achieve the double-way conduction block by radiofrequency catheter ablation of TVC-TA isthmus, is a reliable method for treating atrial flutter

  13. New Radiofrequency Exposure System with Real Telecommunication Signals

    Directory of Open Access Journals (Sweden)

    Jakub Misek

    2018-01-01

    Full Text Available In recent years, there has been an increase in the number of studies on biological effects of Electromagnetic (EM fields emitted from Base Transceiver Stations (BTSs. The biological effects of generated and real telecommunication signals produced by different types of exposure systems are discussed. However, the proper exposure methods for such experiments are very limited. We successfully developed a simple and cost-effective exposure unit with real GSM/DCS/UMTS signal from BTS containing proper modulations or intermittence (continuous, interrupted. Signal processing and conditioning unit is based on a Radiofrequency (RF repeater. The downlink signal is filtered by integrated high selectivity passband filters and amplified to a required level. The main part of exposure unit is a Faraday cage with the specimen (exposure area measuring 150 x 250 mm with E-field percent deviation less than 18%. This exposure system can be helpful in experiments with living organisms in in vivo studies and in vitro studies with normal or pathological cells and other micro scale structures being exposed to RF EM fields from BTS.

  14. Characterization of radiofrequency field emissions from smart meters.

    Science.gov (United States)

    Tell, Richard A; Kavet, Robert; Mezei, Gabor

    2013-01-01

    This study presents measurement data that describe radiofrequency emission levels and patterns from smart meters (rated nominally at 1 W) currently deployed in Pacific Gas and Electric Company's service territory in northern California. The smart meters in our investigation could not be set to operate continuously and required a Field Service Unit to induce short periods of emitted fields. To obtain peak field data under both laboratory and ambient conditions, a spectrum analyzer scanned across the 83 transmitting channels between 902 and 928 MHz used by the smart meter on a random frequency-hopping basis. To obtain data describing temporal emission patterns, the analyzer operated in scope mode. Duty cycle was estimated using transmit data acquired by the system operator from over 88,000 m. Instantaneous peak fields at 0.3 m in front of the meters were no more than 15% of the US Federal Communications Commission (FCC) exposure limit for the general public, and 99.9% of the meters operated with a duty cycle of 1.12% or less during the sampling period. In a sample of measurements in six single-detached residences equipped with individual smart meters, no interior measurement of peak field exceeded 1% of the FCC's general public exposure limit.

  15. Interactions between radiofrequency signals and living organisms

    International Nuclear Information System (INIS)

    Boudin, F.; Hours, M.; Lacronique, J.F.; Conil, E.; Hadjem, A.; El Habachi, A.; Wiart, K.; Mann, S.; Kundi, M.; Marc-Vergnes, J.P.; Roosli, M.; Mohler, E.; Frei, P.; Davis, Ch.C.; Balzano, Q.; Ait-Aissa, S.; Billaudel, B.; Poulletier De Gannes, F.; Hurtier, A.; Haro, E.; Taxile, M.; Veyret, B.; Lagroye, I.; Ait-Aissa, S.; Poulletier De Gannes, F.; Athane, A.; Veyret, B.; Lagroye, I.; Yardin, C.; Perrin, A.; Freire, M.; Bachelet, Ch.; Collin, A.; Pla, S.; Debouzy, J.C.; Leveque, Ph.; Van Nierop, L.E.; Huss, A.; Roosli, M.; Egger, M.; Calvez, M.; Salomon, D.

    2010-01-01

    This dossier is composed of 13 articles dealing with the interactions between radio-frequencies and living organisms. It is an overview of various scientific approaches to the field and is of interest for all citizens as the use of mobile phones is widely spread. In the first article it is shown how a model has been built to assess the distribution of the whole body exposure of the population. The second article reviews the state of the art in personal exposure measurements at radio-frequencies. The third article shows that the knowledge of the mechanism of action by which exposure increases the risk of health hazards is necessary. The fourth article shows that individual neuro-psychic factors take a prominent but maybe not unique, part in electromagnetic hypersensitivity. The fifth article shows that no evidence was found to link health disturbances of electromagnetic hypersensitive individuals with radiofrequency exposure. The sixth article shows that the wireless phone is not an athermal hazard to the brain. The seventh article shows that the in utero and post-natal exposure to Wi-Fi does not damage the brains of young rats. The eighth article concludes that recent studies provide no convincing proof of deleterious effects of radiofrequency exposure on the integrity of the blood-brain barrier for specific absorption rates up to 6 W/kg. The ninth article shows that no co-genotoxic effect of radiofrequency was found at levels of exposure that did not induce heating. The tenth article confirms that industry-sponsored studies were least likely to report results suggesting effects. The last article shows that general practitioners are increasingly questioned by their patients about the issue of electromagnetic waves. (A.C.)

  16. Radiofrequency ablation of hepatocellular carcinoma: Mono or multipolar?

    Science.gov (United States)

    Cartier, Victoire; Boursier, Jérôme; Lebigot, Jérôme; Oberti, Frédéric; Fouchard-Hubert, Isabelle; Aubé, Christophe

    2016-03-01

    Thermo-ablation by radiofrequency is recognized as a curative treatment for early-stage hepatocellular carcinoma. However, local recurrence may occur because of incomplete peripheral tumor destruction. Multipolar radiofrequency has been developed to increase the size of the maximal ablation zone. We aimed to compare the efficacy of monopolar and multipolar radiofrequency for the treatment of hepatocellular carcinoma and determine factors predicting failure. A total of 171 consecutive patients with 214 hepatocellular carcinomas were retrospectively included. One hundred fifty-eight tumors were treated with an expandable monopolar electrode and 56 with a multipolar technique using several linear bipolar electrodes. Imaging studies at 6 weeks after treatment, then every 3 months, assessed local effectiveness. Radiofrequency failure was defined as persistent residual tumor after two sessions (primary radiofrequency failure) or local tumor recurrence during follow-up. This study received institutional review board approval (number 2014/77). Imaging showed complete tumor ablation in 207 of 214 lesions after the first session of radiofrequency. After a second session, only two cases of residual viable tumor were observed. During follow-up, there were 46 local tumor recurrences. Thus, radiofrequency failure occurred in 48/214 (22.4%) cases. By multivariate analysis, technique (P radiofrequency failure. Failure rate was lower with the multipolar technique for tumors radiofrequency, multipolar radiofrequency improves tumor ablation with a subsequent lower rate of local tumor recurrence. © 2015 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  17. Radiations

    International Nuclear Information System (INIS)

    Pujol Mora, J.

    1999-01-01

    The exposition to ionizing radiations is a constant fact in the life of the human being and its utilization as diagnostic and therapeutic method is generalized. However, it is notorious how as years go on, the fear to the ionizing radiation seems to persist too, and this fact is not limited to the common individual, but to the technical personnel and professional personnel that labors with them same. (S. Grainger) [es

  18. Radiation

    International Nuclear Information System (INIS)

    Davidson, J.H.

    1986-01-01

    The basic facts about radiation are explained, along with some simple and natural ways of combating its ill-effects, based on ancient healing wisdom as well as the latest biochemical and technological research. Details are also given of the diet that saved thousands of lives in Nagasaki after the Atomic bomb attack. Special comment is made on the use of radiation for food processing. (U.K.)

  19. Polymer light emitting diodes

    International Nuclear Information System (INIS)

    Gautier-Thianche, Emmmanuelle

    1998-01-01

    We study sandwich type semiconducting polymer light emitting diodes; anode/polymer/cathode. ITO is selected as anode, this polymer is a blend of a commercially available polymer with a high hole transport ability: polyvinyl-carbazole and a laser dye: coumarin-515. Magnesium covered with silver is chosen for the anode. We study the influence of polymer thickness and coumarin doping ratio on electroluminescence spectrum, electric characteristics and quantum efficiency. An important drawback is that diodes lifetime remains low. In the second part of our study we determine degradations causes with X-Ray reflectivity experiments. It may be due to ITO very high roughness. We realize a new type of planar electroluminescent device: a channel type electroluminescent device in which polymer layer is inserted into an aluminium channel. Such a device is by far more stable than using classical sandwich structures with the same polymer composition: indeed, charges are generated by internal-field ionization and there is no injection from the electrode to the polymer. This avoids electrochemical reactions at electrodes, thus reducing degradations routes. (author) [fr

  20. Radiation

    International Nuclear Information System (INIS)

    Winther, J.F.; Ulbak, K.; Dreyer, L.; Pukkala, E.; Oesterlind, A.

    1997-01-01

    Exposure to solar and ionizing radiation increases the risk for cancer in humans. Some 5% of solar radiation is within the ultraviolet spectrum and may cause both malignant melanoma and non-melanocytic skin cancer; the latter is regarded as a benign disease and is accordingly not included in our estimation of avoidable cancers. Under the assumption that the rate of occurrence of malignant melanoma of the buttocks of both men and women and of the scalp of women would apply to all parts of the body in people completely unexposed to solar radiation, it was estimated that approximately 95% of all malignant melanomas arising in the Nordic populations around the year 2000 will be due to exposure to natural ultraviolet radiation, equivalent to an annual number of about 4700 cases, with 2100 in men and 2600 in women, or some 4% of all cancers notified. Exposure to ionizing radiation in the Nordic countries occurs at an average effective dose per capita per year of about 3 mSv (Iceland, 1.1 mSv) from natural sources, and about 1 mSv from man-made sources. While the natural sources are primarily radon in indoor air, natural radionuclides in food, cosmic radiation and gamma radiation from soil and building materials, the man-made sources are dominated by the diagnostic and therapeutic use of ionizing radiation. On the basis of measured levels of radon in Nordic dwellings and associated risk estimates for lung cancer derived from well-conducted epidemiological studies, we estimated that about 180 cases of lung cancer (1% of all lung cancer cases) per year could be avoided in the Nordic countries around the year 2000 if indoor exposure to radon were eliminated, and that an additional 720 cases (6%) could be avoided annually if either radon or tobacco smoking were eliminated. Similarly, it was estimated that the exposure of the Nordic populations to natural sources of ionizing radiation other than radon and to medical sources will each give rise to an annual total of 2120

  1. Act of 21 February 1963, Stb. 82, concerning the release of nuclear energy and the use of radioactive materials and of devices emitting ionizing radiations (Nuclear Energy Act) as amended by the Act of 30 June 1967, Stb. 337, and the Act of 8 May 1974, Stb. 291

    International Nuclear Information System (INIS)

    1963-01-01

    This basic Act governs all nuclear activities in the Netherlands and determines the Government's competence and the obligations of those involved in the nuclear field. It establishes definitions and sets up bodies to advise the Government in the different nuclear sectors and covers nuclear installations, fissionable materials, ores, radioactive materials, radiation-emitting devices and their licensing. It was brought into force progressively by decrees made in implementation of its provisions, which lay down detailed regulations for the activity concerned. The chapters of the Act not yet in force were brought into operation on 1 January 1970 by the Nuclear Energy Act (Implantation) Decree of 12 November 1969. (NEA) [fr

  2. Radiofrequency electromagnetic fields in the Cookridge area of Leeds

    International Nuclear Information System (INIS)

    Fuller, K.; Gulson, A.D.; Judd, P.M.; Lowe, A.J.; Shaw, J.

    2002-01-01

    On the 8 and 9 May 2002 representatives of the National Radiological Protection Board (NRPB) performed a radiofrequency electromagnetic field survey in the Cookridge area of Leeds in order to assess exposure to radio signals from transmitters mounted on a water tower/a lattice tower and a radio station tower. Guidelines on limiting exposure to radio signals have been published by NRPB and the International Commission on Non-Ionizing Radiation Protection (ICNIRP). These guidelines are designed to prevent established adverse effects on human health. During this survey, the total exposures due to all radio signals from 30 MHz to 18000 MHz (18 GHz) were measured. This frequency range was chosen as it includes mobile phone base station transmissions, which are at around 900 and 1800 MHz and super high frequency (SHF) transmissions from most of the large microwave dish antennas mounted on the towers. In addition, other major sources of radiofrequency electromagnetic fields in the environment such as broadcast radio and television transmissions are included in this range. Measurements of power density were made at eight locations in the vicinity of the transmitter sites. Comparison of the measurements with the guidelines showed that the total exposure from radio signals measured between 30 MHz and 18 GHz ranged from 0.26 millionths (0.000026%) to 190 millionths (0.019%) of the NRPB investigation level and from 1.6 millionths (0.00016%) to 1400 millionths (0.14%) of the ICNIRP reference level for exposure of the general public. All the measured exposures are therefore many times below guideline levels and are not considered hazardous. (author)

  3. Positron emitting pharmaceuticals

    International Nuclear Information System (INIS)

    Rajan, M.G.R.

    2012-01-01

    Positron Emission Tomography (PET) imaging of physiology at the molecular level bridges the gap between laboratory science and clinical medicine by providing the most specific and sensitive means for imaging molecular pathways and interactions in tissues of man. PET-imaging requires the use Positron Emitting Radiopharmaceuticals (PRPs), which are radioactively labeled 'true metabolites' i.e., sugars, amino acids, fatty acids etc., essentially made of H, C, N and O which the cells in the body can metabolize. The PET-isotopes: 11 C, 15 O, 13 N and 18 F (instead of H) are cyclotron produced and are short-lived, which places several constraints on the synthesis time for the PRPs, quality control and their clinical use as compared to the conventional 99m Tc- and other SPECT-RPs widely used in nuclear medicine. There are large number of published reports showing the utility of several PRPs labeled with 18 F (T 1/2 = 110 min) and 11 C (T 1/2 = 20 min). A few PRPs have been labeled with 13 N (T 1/2 = 10 min). 15 O (T 1/2 = 2min) is used mostly as H 2 15 O, C 15 or C 15 O 2 . 18 F-radiopharmaceuticals can be made at a medical cyclotron facility and sent to PET -imaging centres, which can be reached in a couple of hours. The sensitivity of PET -imaging has encouraged R and D in several other PRPs, labeled with viz., 68 Ga (generator produced, T 1/2 68 min), 124 I (cyclotron, T 1/2 4.2 d), 82 Rb (generator, T 1/2 75s), 64 Cu (cyclotron, T 1/2 12h), and 94m Tc (cyclotron, T 1/2 52 min). Due to its relevance in several diseases, particularly cancer, PET-imaging has made major scientific contribution to drug development, particularly for neurological diseases and cancer treatment. (author)

  4. Fraxelated radiofrequency device for acne scars

    Science.gov (United States)

    Rao, Babar K.; Khokher, Sairah

    2012-09-01

    Acne scars can be improved with various treatments such as topical creams, chemical peels, dermal fillers, microdermabrasion, laser, and radiofrequency devices. Some of these treatments especially lasers and deep chemical peels can have significant side effects such as post inflammatory hyperpigmentation in darker skin types. Fraxelated RF Laser devices have been reported to have lower incidence of side effects in all skin phototypes. Nine patients between ages 18 and 35 of various skin phototypes were selected from a private practice and treated with a RF fraxelated device (E-matrix) for acne scars. Outcomes were measured by physician observation, subjective feedback received by patients, and comparison of before and after photographs. In this small group of patients with various skin phototypes, fraxelated radiofrequency device improved acne scars with minimal side effects and downtime.

  5. Arthroscopic surgery using radio-frequency electrocautery

    International Nuclear Information System (INIS)

    Takatsuka, Shigeyuki; Yoshida, Kan; Nakagawa, Kiyomasa; Yamamoto, Etsuhide; Kubota, Yoshiyuki; Narinobou, Masayoshi; Terai, Koichi; Hasegawa, Hiroshi

    2008-01-01

    Arthroscopic surgery using radio-frequency electrocautery was carried out on 23 temporomandibular joints (TMJs) in 13 patients. Because these patients did not respond to conservative therapy, surgery was indicated. Preoperative MRI showed anterior disc displacement without reduction in all patients. Disturbed translation was also recognized in all of the discs and mandibular condyles. Intraoperative arthroscopic examination showed severe fibrous adhesion in the upper joint compartment and disc displacement. Four joints showed perforation between the disc and retrodiscal tissue. Postoperative findings included an increased range of vertical maximal mouth opening and decreased pain on mandibular movement. Analyses of postoperative MRI indicated recovery of disc and condylar translation. These results suggested that the introduction of arthroscopic surgery using radiofrequency electrocautery would significantly reduce the number of patients with osteoarthritic TMJ disorders. (author)

  6. Temperature-controlled irrigated tip radiofrequency catheter ablation

    DEFF Research Database (Denmark)

    Petersen, H H; Chen, X; Pietersen, Adrian

    1998-01-01

    INTRODUCTION: In patients with ventricular tachycardias due to structural heart disease, catheter ablation cures radiofrequency ablation. Irrigated tip radiofrequency ablation using power control and high infusion rates enlarges lesion......: We conclude that temperature-controlled radiofrequency ablation with irrigated tip catheters using low target temperature and low infusion rate enlarges lesion size without increasing the incidence of cratering and reduces coagulum formation of the tip....

  7. Powerful infrared emitting diodes

    Directory of Open Access Journals (Sweden)

    Kogan L. M.

    2012-02-01

    Full Text Available Powerful infrared LEDs with emission wavelength 805 ± 10, 870 ± 20 and 940 ± 10 nm developed at SPC OED "OPTEL" are presented in the article. The radiant intensity of beam diode is under 4 W/sr in the continuous mode and under 100 W/sr in the pulse mode. The radiation power of wide-angle LEDs reaches 1 W in continuous mode. The external quantum efficiency of emission IR diodes runs up to 30%. There also has been created infrared diode modules with a block of flat Fresnel lenses with radiant intensity under 70 W/sr.

  8. Effect of Radiofrequency Endometrial Ablation on Dysmenorrhea.

    Science.gov (United States)

    Wyatt, Sabrina N; Banahan, Taylor; Tang, Ying; Nadendla, Kavita; Szychowski, Jeff M; Jenkins, Todd R

    To examine rates of dysmenorrhea after radiofrequency endometrial ablation in patients with and without known dysmenorrhea symptoms prior to the procedure in a diverse population. Retrospective cohort study (Canadian Task Force classification II-2). Academic gynecology practice. A total of 307 women underwent endometrial ablation between 2007 and 2013 at our institution. Patients who had preoperative and postoperative pain symptom assessments as well as a description of pain timing recorded were included in our analysis. Exclusion criteria were age dysmenorrhea was evaluated. Demographic information and other outcome variables were used to evaluate factors associated with resolution of dysmenorrhea. A total of 307 patients who underwent radiofrequency endometrial ablation were identified. After exclusions, 296 charts were examined, and 144 patients met our enrollment criteria. The mean age of the study cohort was 45.4 ± 6.2 years; 57 patients (40%) were African American, 16 (11%) had a body mass index (BMI) > 40, and 41 (29%) were of normal weight. Preoperative dysmenorrhea was reported by 100 patients (69%); 48 of these patients (48%) experienced resolution of symptoms postoperatively. Only 3 of the 44 patients (7%) without preoperative dysmenorrhea reported new-onset dysmenorrhea postoperatively. Significantly fewer patients had dysmenorrhea after compared to before radiofrequency ablation (55 of 144 [38%] vs 100 of 144 [69%]; p dysmenorrhea after ablation was associated with reduction in bleeding volume (p = .048) but not with a reduction in frequency of bleeding (p = .12). Approximately one-half of women who undergo radiofrequency endometrial ablation to treat heavy menstrual bleeding who also have preoperative dysmenorrhea exhibit documented pain resolution after the procedure. Resolution of dysmenorrhea is more likely if menstrual flow volume is decreased postprocedure. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights reserved.

  9. Radiofrequency Wire Recanalization of Chronically Thrombosed TIPS

    Energy Technology Data Exchange (ETDEWEB)

    Majdalany, Bill S., E-mail: bmajdala@med.umich.edu [University of Michigan Health System, Division of Interventional Radiology, Department of Radiology (United States); Elliott, Eric D., E-mail: eric.elliott@osumc.edu [The Ohio State University Wexner Medical Center, Division of Interventional Radiology, Department of Radiology (United States); Michaels, Anthony J., E-mail: Anthony.michaels@osumc.edu; Hanje, A. James, E-mail: James.Hanje@osumc.edu [The Ohio State University Wexner Medical Center, Division of Gastroenterology and Hepatology, Department of Medicine (United States); Saad, Wael E. A., E-mail: wsaad@med.umich.edu [University of Michigan Health System, Division of Interventional Radiology, Department of Radiology (United States)

    2016-07-15

    Radiofrequency (RF) guide wires have been applied to cardiac interventions, recanalization of central venous thromboses, and to cross biliary occlusions. Herein, the use of a RF wire technique to revise chronically occluded transjugular intrahepatic portosystemic shunts (TIPS) is described. In both cases, conventional TIPS revision techniques failed to revise the chronically thrombosed TIPS. RF wire recanalization was successfully performed through each of the chronically thrombosed TIPS, demonstrating initial safety and feasibility in this application.

  10. Issues in epidemiological studies of radiofrequency workers

    International Nuclear Information System (INIS)

    Hocking, B.

    1985-01-01

    The paper reviews some of the issues in a proposed epidemiological study of radiofrequency workers. First a few other epidemiological studies are discussed to illustrate some of the common problems such as inadequate definition of effects and/or exposure. Then technical problems in determining dosage and responses as well as study design are reviewed, and finally the administrative aspects of ethics, industrial relations and costs are considered

  11. ROLE OF RADIOFREQUENCY ABLATION IN ADENOMA SEBACEUM

    Directory of Open Access Journals (Sweden)

    Ch. Madh

    2016-03-01

    Full Text Available Adenoma sebaceum, pathognomonic of tuberous sclerosis, are tiny angiofibromas which commonly occur over central part of face. Recurrence after treatment is common and hence a need for inexpensive, safe and efficient treatment is required. Radiofrequency ablation is a safe and an economical procedure and has been known to cause less scarring with good aesthetic results compared to other ablative methods such as electrocautery.

  12. Radiofrequency amplifier based on a DC superconducting quantum interference device

    International Nuclear Information System (INIS)

    Martinis, J.M.; Hilbert, C.; Clarke, J.

    1986-01-01

    A method is described of amplifying a radiofrequency signal consisting of: disposing a single symmetrically biased dc SQUID and an input coil within a superconducting shield, the dc SQUID having a superconducting ring interrupted by two shunted Josephson junctions, and the input coil being inductively coupled solely to the ring of the single SQUID, establishing a constant magnetic flux threading the SQUID ring, applying the radiofrequency signal to the input coil from outside of the superconducting shield, obtaining an amplified radiofrequency signal solely from across the ring of the single SQUID, transmitting the amplified radiofrequency signal from across the SQUID ring to the outside of the superconducting shield

  13. Diverse Radiofrequency Sensitivity and Radiofrequency Effects of Mobile or Cordless Phone near Fields Exposure in Drosophila melanogaster

    Science.gov (United States)

    Geronikolou, Styliani; Zimeras, Stelios; Davos, Constantinos H.; Michalopoulos, Ioannis; Tsitomeneas, Stephanos

    2014-01-01

    Introduction The impact of electromagnetic fields on health is of increasing scientific interest. The aim of this study was to examine how the Drosophila melanogaster animal model is affected when exposed to portable or mobile phone fields. Methods/Results Two experiments have been designed and performed in the same laboratory conditions. Insect cultures were exposed to the near field of a 2G mobile phone (the GSM 2G networks support and complement in parallel the 3G wide band or in other words the transmission of information via voice signals is served by the 2G technology in both mobile phones generations) and a 1880 MHz cordless phone both digitally modulated by human voice. Comparison with advanced statistics of the egg laying of the second generation exposed and non-exposed cultures showed limited statistical significance for the cordless phone exposed culture and statistical significance for the 900 MHz exposed insects. We calculated by physics, simulated and illustrated in three dimensional figures the calculated near fields of radiation inside the experimenting vials and their difference. Comparison of the power of the two fields showed that the difference between them becomes null when the experimental cylinder radius and the height of the antenna increase. Conclusions/Significance Our results suggest a possible radiofrequency sensitivity difference in insects which may be due to the distance from the antenna or to unexplored intimate factors. Comparing the near fields of the two frequencies bands, we see similar not identical geometry in length and height from the antenna and that lower frequencies tend to drive to increased radiofrequency effects. PMID:25402465

  14. Diverse radiofrequency sensitivity and radiofrequency effects of mobile or cordless phone near fields exposure in Drosophila melanogaster.

    Directory of Open Access Journals (Sweden)

    Styliani Geronikolou

    Full Text Available INTRODUCTION: The impact of electromagnetic fields on health is of increasing scientific interest. The aim of this study was to examine how the Drosophila melanogaster animal model is affected when exposed to portable or mobile phone fields. METHODS/RESULTS: Two experiments have been designed and performed in the same laboratory conditions. Insect cultures were exposed to the near field of a 2G mobile phone (the GSM 2G networks support and complement in parallel the 3G wide band or in other words the transmission of information via voice signals is served by the 2G technology in both mobile phones generations and a 1880 MHz cordless phone both digitally modulated by human voice. Comparison with advanced statistics of the egg laying of the second generation exposed and non-exposed cultures showed limited statistical significance for the cordless phone exposed culture and statistical significance for the 900 MHz exposed insects. We calculated by physics, simulated and illustrated in three dimensional figures the calculated near fields of radiation inside the experimenting vials and their difference. Comparison of the power of the two fields showed that the difference between them becomes null when the experimental cylinder radius and the height of the antenna increase. CONCLUSIONS/SIGNIFICANCE: Our results suggest a possible radiofrequency sensitivity difference in insects which may be due to the distance from the antenna or to unexplored intimate factors. Comparing the near fields of the two frequencies bands, we see similar not identical geometry in length and height from the antenna and that lower frequencies tend to drive to increased radiofrequency effects.

  15. Diverse radiofrequency sensitivity and radiofrequency effects of mobile or cordless phone near fields exposure in Drosophila melanogaster.

    Science.gov (United States)

    Geronikolou, Styliani; Zimeras, Stelios; Davos, Constantinos H; Michalopoulos, Ioannis; Tsitomeneas, Stephanos

    2014-01-01

    The impact of electromagnetic fields on health is of increasing scientific interest. The aim of this study was to examine how the Drosophila melanogaster animal model is affected when exposed to portable or mobile phone fields. Two experiments have been designed and performed in the same laboratory conditions. Insect cultures were exposed to the near field of a 2G mobile phone (the GSM 2G networks support and complement in parallel the 3G wide band or in other words the transmission of information via voice signals is served by the 2G technology in both mobile phones generations) and a 1880 MHz cordless phone both digitally modulated by human voice. Comparison with advanced statistics of the egg laying of the second generation exposed and non-exposed cultures showed limited statistical significance for the cordless phone exposed culture and statistical significance for the 900 MHz exposed insects. We calculated by physics, simulated and illustrated in three dimensional figures the calculated near fields of radiation inside the experimenting vials and their difference. Comparison of the power of the two fields showed that the difference between them becomes null when the experimental cylinder radius and the height of the antenna increase. Our results suggest a possible radiofrequency sensitivity difference in insects which may be due to the distance from the antenna or to unexplored intimate factors. Comparing the near fields of the two frequencies bands, we see similar not identical geometry in length and height from the antenna and that lower frequencies tend to drive to increased radiofrequency effects.

  16. Association of Exposure to Radio-Frequency Electromagnetic Field Radiation (RF-EMFR Generated by Mobile Phone Base Stations with Glycated Hemoglobin (HbA1c and Risk of Type 2 Diabetes Mellitus

    Directory of Open Access Journals (Sweden)

    Sultan Ayoub Meo

    2015-11-01

    Full Text Available Installation of mobile phone base stations in residential areas has initiated public debate about possible adverse effects on human health. This study aimed to determine the association of exposure to radio frequency electromagnetic field radiation (RF-EMFR generated by mobile phone base stations with glycated hemoglobin (HbA1c and occurrence of type 2 diabetes mellitus. For this study, two different elementary schools (school-1 and school-2 were selected. We recruited 159 students in total; 96 male students from school-1, with age range 12–16 years, and 63 male students with age range 12–17 years from school-2. Mobile phone base stations with towers existed about 200 m away from the school buildings. RF-EMFR was measured inside both schools. In school-1, RF-EMFR was 9.601 nW/cm2 at frequency of 925 MHz, and students had been exposed to RF-EMFR for a duration of 6 h daily, five days in a week. In school-2, RF-EMFR was 1.909 nW/cm2 at frequency of 925 MHz and students had been exposed for 6 h daily, five days in a week. 5–6 mL blood was collected from all the students and HbA1c was measured by using a Dimension Xpand Plus Integrated Chemistry System, Siemens. The mean HbA1c for the students who were exposed to high RF-EMFR was significantly higher (5.44 ± 0.22 than the mean HbA1c for the students who were exposed to low RF-EMFR (5.32 ± 0.34 (p = 0.007. Moreover, students who were exposed to high RF-EMFR generated by MPBS had a significantly higher risk of type 2 diabetes mellitus (p = 0.016 relative to their counterparts who were exposed to low RF-EMFR. It is concluded that exposure to high RF-EMFR generated by MPBS is associated with elevated levels of HbA1c and risk of type 2 diabetes mellitus.

  17. Miniature scanning electron microscope for investigation of the interior surface of a superconducting Nb radiofrequency accelerating cavity

    International Nuclear Information System (INIS)

    Mathewson, A.G.; Grillot, A.

    1982-01-01

    A miniature scanning electron microscope with an electron beam diameter approx.1 μm has been constructed for high resolution examination at room temperature of the interior surface of a superconducting Nb radiofrequency accelerating cavity. Various objects and surface structures were observed, some of which could be correlated with lossy regions or ''hot spots'' detected previously on the outside surface during cavity operation at < or =4.2 K by a chain of carbon resistors. No internal surface features were observed which could conclusively be correlated with field emitting electron sources

  18. Radiofrequency initiation and radiofrequency sustainment of laser initiated seeded high pressure plasma

    International Nuclear Information System (INIS)

    Paller, Eric S.; Scharer, John E.; Akhtar, Kamran; Kelly, Kurt; Ding, Guowen

    2001-01-01

    We examine radiofrequency initiation of high pressure(1-70 Torr) inductive plasma discharges in argon, nitrogen, air and organic seed gas mixtures. Millimeter wave interferometry, optical emission and antenna wave impedance measurements for double half-turn helix and helical inductive antennas are used to interpret the rf/plasma coupling, measure the densities in the range of 10 12 cm -3 and analyze the ionization and excited states of the gas mixtures. We have also carried out 193 nm excimer laser initiation of an organic gas seed plasma which is sustained at higher pressures(150 Torr) by radiofrequency coupling at 2.8 kW power levels

  19. White organic light emitting diodes

    Energy Technology Data Exchange (ETDEWEB)

    Rosenow, Thomas Conrad

    2011-03-22

    Three approaches were taken in order to achieve reproducible and highly efficient white OLEDs with excellent colour quality. The first approach is based on the triplet harvesting concept. Otherwise unused triplet excitons are transferred from a fluorescent to a phosphorescent emitter with a smaller triplet energy. Because a blue emitter allowing for triplet transfer to a phosphorescent green emitter was not available, a model system for a three-colour white OLED was developed and investigated. This model device consists of the fluorescent blue emitter 4P-NPD and the phosphorescent emitters Ir(dhfpy){sub 2}acac and Ir(MDQ){sub 2}acac emitting in the yellow and red region, respectively. Here, it was shown that both phosphorescent emitters are excited by triplet diffusion and not by direct charge carrier recombination. The second approach is based on a hybrid white OLED with a single emission layer. This layer is a combination of a fluorescent blue and two phosphorescent emitters in a common matrix material. Because of the above mentioned lack of a blue emitter, which allows for triplet transfer to a green phosphorescent emitter, the concentrations of all emitters were chosen in a way that exciton transfer between the emitters was suppressed. The result is a non-radiative recombination of triplet excitons on the fluorescent blue emitter and an accordingly low quantum efficiency. However, a remarkable colour stability against varying brightness was achieved with this OLED. The most successful approach is based on a stacked OLED. Here, the concept of triplet harvesting is limited to triplet transfer between a fluorescent blue and a phosphorescent red emitter. The resulting spectral gap is filled by a full phosphorescent unit comprising the emission of a green and a yellow emitter, which is stacked on top of the triplet harvesting OLED. By individually optimising both units, it was possible to reach lighting relevant luminous efficacies up to {eta}{sub {nu}}=33 lm/W at

  20. Regulation on Radiation Safety of Guatemala

    International Nuclear Information System (INIS)

    2001-03-01

    This regulation includes all the requirements administrative, radiation protection, that licensees must meet in order to obtain authorization from the competent authority to apply and use radiation sources, equipment emiting ionizing radiation in different practices authorized

  1. Decrease of the exposure to electromagnetic waves emitted by mobile phone relay antennas. Synthesis report on experimentations performed by the COPIC

    International Nuclear Information System (INIS)

    2013-01-01

    A synthetic introduction outlines that simulations reveal a globally low level of public exposure to waves emitted by relay antennas, discusses lessons learned from exposure measurements, indicates that possibilities of treatment exist for the most exposed places, outlines the consequences of a global decrease of exposure on service coverage and quality, outlines a necessary increase of the number of antennas to conceal low exposure and coverage, and that the deployment of 4G should result in an increase of public exposure. Then, the main part of the report presents the fundamental notions related to mobile phone networks and radio waves (electromagnetic radiation, radiofrequency waves and mobile phones, relay antennas and networks, legal thresholds), the implemented method the characteristics of studied areas. It reports the methodology, exposure simulations and exposure measurements, coverage simulations and service quality measurements. It discusses the treatment of the most exposed locations (results from simulations and from measurements). It discusses the results of simulations and experimentations of a decrease of the power of relay antennas, of the simulation of the impact of theoretical 4G additional antennas on exposure. Results obtained in different towns and locations are reported in appendix

  2. Long-wave UVA radiation excited warm white-light emitting NaGdTiO4: Tm3+/Dy3+/Eu3+ ions tri-doped phosphors: Synthesis, energy transfer and color tunable properties

    International Nuclear Information System (INIS)

    Bharat, L. Krishna; Du, Peng; Yu, Jae Su

    2016-01-01

    NaGdTiO 4 (NGT) phosphors doped with different activator ions (Tm 3+ , Dy 3+ , and Eu 3+ ) were synthesized by a conventional solid-state reaction method in an ambient atmosphere. These phosphors were characterized by scanning electron microscope images, transmission electron microscope images, X-ray diffraction patterns, Fourier transform infrared spectra, and photoluminescence spectra. All the samples were crystallized in an orthorhombic phase with a space group of Pbcm (57). In Tm 3+ /Dy 3+ ions co-doped samples, white-light emission was observed under near-ultraviolet (NUV) excitation. In addition, the energy transfer between Tm 3+ and Dy 3+ ions was proved to be a resonant type via an electric dipole–dipole mechanism and the critical distance of energy transfer was calculated to be 19.91 Å. Furthermore, Tm 3+ /Dy 3+ /Eu 3+ ions tri-doped NGT phosphors demonstrated warm white-light emission by appropriately tuning the activator content, based on the principle of energy transfer. These NUV wavelength excitable phosphors exhibit great potential as a single-phase full-color emitting phosphor for white light-emitting diode applications. - Highlights: • The pebble shaped NaGdTiO 4 particles were prepared by solid-state reaction method. • Tm 3+ and Dy 3+ single doping gives respective blue and cool white light emission. • The Tm 3+ /Dy 3+ ions co-doped samples give CIE values near to standard white light. • Addition of Eu 3+ ions shifts the CIE values towards warm white light region. • This single phase white light emitting phosphors have lower CCT values (<5000 K).

  3. Dose-dependent and gender-related radiation-induced transcription alterations of Gadd45a and Ier5 in human lymphocytes exposed to gamma ray emitted by 60Co

    International Nuclear Information System (INIS)

    Tavakoli, H.; Manoochehri, M.; Mosalla, S. M. M.; Ghafori, M.; Karimi, A. A.

    2013-01-01

    Growth arrest DNA damage-inducible 45a gene (Gadd45a) and immediate early response gene 5 (Ier5) have been emphasised as ideal radiation bio-markers in several reports. However, some aspects of radiation-induced transcriptional alterations of these genes are unknown. In this study, gender-dependency and dose-dependency as two factors that may affect radiation induced transcription of Gadd45a and Ier5 genes were investigated. Human lymphocyte cells from six healthy voluntary blood donors (three women and three men) were irradiated in vitro with doses of 0.5-4.0 Gy from a 60 Co source and RNA isolated 4 h later using the High Pure RNA Isolation Kit. Dose and gender dependency of radiation-induced transcriptional alterations of Gadd45a and Ier5 genes were studied by quantitative real-time polymerase chain reaction. The results showed that as a whole, Gadd45a and Ier5 gave responses to gamma rays, while the responses were independent of radiation doses. Therefore, regardless of radiation dose, Gadd45a and Ier5 can be considered potential radiation bio-markers. Besides, although radiation-induced transcriptional alterations of Gadd45a in female and male lymphocyte samples were insignificant at 0.5 Gy, at other doses, their quantities in female samples were at a significantly higher level than in male samples. Radiation induced transcription of Ier5 of females samples had a reduction in comparison with male samples at 1 and 2 Gy, but at doses of 0.5 and 4 Gy, females were significantly more susceptible to radiation-induced transcriptional alteration of Ier5. (authors)

  4. Energy Saving Glass Lamination via Selective Radio-Frequency Heating

    Energy Technology Data Exchange (ETDEWEB)

    Shulman, Holly S.; Allan, Shawn M.

    2009-11-11

    This Inventions and Innovations program supported the technical and commercial research and development needed to elevate Ceralink's energy saving process for flat glass lamination from bench scale to a self-supporting technology with significant potential for growth. Radio-frequency heating was any un-explored option for laminating glass prior to this program. With significant commercial success through time and energy savings in the wood, paper, and plastics industries, RF heating was found to have significant promise for the energy intensive glass lamination industry. A major technical goal of the program was to demonstrate RF lamination across a wide range of laminate sizes and materials. This was successfully accomplished, dispelling many skeptics' concerns about the abilities of the technology. Ceralink laminated panels up to 2 ft x 3 ft, with four sets processed simultaneously, in a 3 minute cycle. All major categories of interlayer materials were found to work with RF lamination. In addition to laminating glass, other materials including photovoltaic silicon solar cells, light emitting diodes, metallized glass, plastics (acrylic and polycarbonate), and ceramics (alumina) were found compatible with the RF process. This opens up a wide range of commercial opportunities beyond the initially targeted automotive industry. The dramatic energy savings reported for RF lamination at the bench scale were found to be maintained through the scale up of the process. Even at 2 ft x 3 ft panel sizes, energy savings are estimated to be at least 90% compared to autoclaving or vacuum lamination. With targeted promotion through conference presentations, press releases and internet presence, RF lamination has gained significant attention, drawing large audiences at American Ceramic Society meetings. The commercialization success of the project includes the establishment of a revenue-generating business model for providing process development and demonstrations for

  5. Effect of radiofrequency on capacitance of low density plasma sheath

    International Nuclear Information System (INIS)

    Carneiro, L.T.; Cunha Rapozo, C. da

    1988-01-01

    It is shown that the influence of induced radiofrequency potential (V RF ) modifies the Bohm theory on ion saturation current, measured with Langmuir probes. The effect of radiofrequency potential on diode type plasma sheath resonance is also investigated. (M.C.K.)

  6. 77 FR 43535 - Grantee Codes for Certified Radiofrequency Equipment

    Science.gov (United States)

    2012-07-25

    ... FEDERAL COMMUNICATIONS COMMISSION 47 CFR Part 2 [FCC 12-60] Grantee Codes for Certified Radiofrequency Equipment AGENCY: Federal Communications Commission. ACTION: Final rule. SUMMARY: This document... authorization program for radiofrequency (RF) devices under part 2 of its rules. This program is one of the...

  7. CT-guided radiofrequency tumor ablation in children

    International Nuclear Information System (INIS)

    Botsa, Evanthia; Poulou, Loukia S.; Koundouraki, Antonia; Thanos, Loukas; Koutsogiannis, Ioannis; Ziakas, Panayiotis D.; Alexopoulou, Efthimia

    2014-01-01

    Image-guided radiofrequency ablation is a well-accepted technique of interventional oncology in adults. To evaluate the efficacy and safety of CT-guided radiofrequency ablation as a minimally invasive treatment for metastatic neoplasms in children. A total of 15 radiofrequency ablation sessions were performed in 12 children and young adults (median age 9.5; range 5-18 years) with metastatic malignancies. Seven children and young adults had secondary hepatic lesions, three had pulmonary and two had bone lesions. Radiofrequency ablation was performed under conscious sedation. The median lesion size was 1.7 cm (range 1.3-2.8 cm). The median time for ablation was 8 min (range 7-10 min). Radiofrequency procedures were technically successful in all tumors. Postablation imaging immediately after, and 1 month and 3 months after radiofrequency ablation showed total necrosis in all patients. At 6-month follow-up, three patients (all with lesion size >2 cm) had local recurrence and underwent a second radiofrequency ablation session. At 2-year follow-up no patient had recurrence of the treated tumor. Post-ablation syndrome occurred in four children. No major complication occurred. CT-guided radiofrequency tumor ablation was safe and efficient for palliative treatment in our cohort of patients. (orig.)

  8. Mechanisms for enlarging lesion size during irrigated tip radiofrequency ablation

    DEFF Research Database (Denmark)

    Petersen, Helen Høgh; Roman-Gonzalez, Javier; Johnson, Susan B

    2004-01-01

    INTRODUCTION: Irrigated tip radiofrequency ablation of cardiac arrhythmias was developed to increase the size of the radiofrequency-induced lesion, since cooling of the electrode tip allows use of higher power settings. The purpose of this study was to determine if the increased lesion size during...

  9. Occupational exposure to radiofrequency fields in antenna towers

    International Nuclear Information System (INIS)

    Alanko, T.; Hietanen, M.

    2007-01-01

    Exposure of workers to radiofrequency fields was assessed in two medium-sized antenna towers. Towers had transmitting antennas from different networks, e.g. mobile phone networks, radio and digital TV sub-stations and amateur radio. The levels of radiofrequency fields were measured close to the ladders of the towers. All measured values were below ICNIRP occupational reference levels. (authors)

  10. CT-guided radiofrequency tumor ablation in children

    Energy Technology Data Exchange (ETDEWEB)

    Botsa, Evanthia [National and Kapodistrian University of Athens, First Pediatric Clinic, Agia Sofia Children' s Hospital, Athens (Greece); Poulou, Loukia S.; Koundouraki, Antonia; Thanos, Loukas [Sotiria General Hospital for Chest Diseases, Department of Medical Imaging and Interventional Radiology, Athens (Greece); Koutsogiannis, Ioannis [General Military Hospital NIMTS, Department of Medical Imaging, Athens (Greece); Ziakas, Panayiotis D. [Warren Alpert Medical School of Brown University Rhode Island Hospital, Division of Infectious Diseases, Providence, RI (United States); Alexopoulou, Efthimia [Attikon University Hospital, Second Department of Radiology, Athens University School of Medicine, Athens (Greece)

    2014-11-15

    Image-guided radiofrequency ablation is a well-accepted technique of interventional oncology in adults. To evaluate the efficacy and safety of CT-guided radiofrequency ablation as a minimally invasive treatment for metastatic neoplasms in children. A total of 15 radiofrequency ablation sessions were performed in 12 children and young adults (median age 9.5; range 5-18 years) with metastatic malignancies. Seven children and young adults had secondary hepatic lesions, three had pulmonary and two had bone lesions. Radiofrequency ablation was performed under conscious sedation. The median lesion size was 1.7 cm (range 1.3-2.8 cm). The median time for ablation was 8 min (range 7-10 min). Radiofrequency procedures were technically successful in all tumors. Postablation imaging immediately after, and 1 month and 3 months after radiofrequency ablation showed total necrosis in all patients. At 6-month follow-up, three patients (all with lesion size >2 cm) had local recurrence and underwent a second radiofrequency ablation session. At 2-year follow-up no patient had recurrence of the treated tumor. Post-ablation syndrome occurred in four children. No major complication occurred. CT-guided radiofrequency tumor ablation was safe and efficient for palliative treatment in our cohort of patients. (orig.)

  11. Radiofrequency and health. Expertise update. Opinion of the ANSES. Collective expertise report

    International Nuclear Information System (INIS)

    Cardis, Elisabeth; Dore, Jean-Francois; Marc-Vergnes, Jean-Pierre; Agnani, Jean-Benoit; Bruguiere, Pierre; Crouzier, David; Debaz, Josquin; Debuire, Brigitte; Deltour, Isabelle; LE Drean, Yves; Ledoigt, Gerard; Letertre, Thierry; Marchand, Dorothee; Massardier-Pilonchery, Amelie; Nadi, Mustapha; Pereira De Vasconcelos, Anne; Hours, Martine; Fite, Johanna; Merckel, Olivier; Roth, Olivia; Vergriette, Benoit; Saddoki, Sophia

    2013-10-01

    In a context of development of new technologies of wireless communications, and therefore of radio-electric signals used to transmit information, this voluminous document reports a detailed study on the effects of radiofrequency on health. It is notably based on a large literature survey and on an assessment of the level of proof of these effects by experts (proved, possible, probable, insufficiently proved, or no effect on mankind). These effects can be either biological or on health. The report presents the context, scope and modalities of the expertise study, presents the main artificial and natural sources of radiofrequency radiation, gives a detailed presentation of new exposure sources (new signals, new radio-electric networks and their applications like mobile phones, pads, mobile television, local wireless networks, RFID, so on). It describes metrology and dose measurement techniques for electromagnetic fields (exposure characterization in laboratory, characterization of the electromagnetic environment, individual exposure measurement devices, digital dosimetry). It addresses the efficiency of anti-wave devices. The next part presents the literature survey (method, analysis, results). The authors then report an assessment of the risk level related to radio-frequencies for the central nervous system (neurotoxicity mechanisms, cognitive functions, memory and behaviour, sleep and circadian rhythms, hearing functions, neurological and neuro-degenerative diseases), and an assessment of the risk level of radio-frequencies for other non-carcinogenic effects (possible mechanisms, reproduction, immunology, endocrine system, and so on). They discuss the researches on potential carcinogenic mechanisms. They give an overview of the evolutions of regulations and management measures in France, and propose a set of recommendations

  12. Determination of the exposure speed of radiation emitted by the linear accelerator, using the code MCNP5 to evaluate the radiotherapy room shields of ABC Hospital; Determinacion de la rapidez de exposicion de la radiacion emitida por el acelerador lineal, utilizando el codigo MCNP5, para evaluar los blindajes de la sala de radioterapia del Hospital ABC

    Energy Technology Data Exchange (ETDEWEB)

    Corral B, J. R.

    2015-07-01

    Humans should avoid exposure to radiation, because the consequences are harmful to health. Although there are different emission sources of radiation, generated by medical devices they are usually of great interest, since people who attend hospitals are exposed in one way or another to ionizing radiation. Therefore, is important to conduct studies on radioactive levels that are generated in hospitals, as a result of the use of medical equipment. To determine levels of exposure speed of a radioactive facility there are different methods, including the radiation detector and computational method. This thesis uses the computational method. With the program MCNP5 was determined the speed of the radiation exposure in the radiotherapy room of Cancer Center of ABC Hospital in Mexico City. In the application of computational method, first the thicknesses of the shields were calculated, using variables as: 1) distance from the shield to the source; 2) desired weekly equivalent dose; 3) weekly total dose equivalent emitted by the equipment; 4) occupation and use factors. Once obtained thicknesses, we proceeded to model the bunker using the mentioned program. The program uses the Monte Carlo code to probabilistic ally determine the phenomena of interaction of radiation with the shield, which will be held during the X-ray emission from the linear accelerator. The results of computational analysis were compared with those obtained experimentally with the detection method, for which was required the use of a Geiger-Muller counter and the linear accelerator was programmed with an energy of 19 MV with 500 units monitor positioning the detector in the corresponding boundary. (Author)

  13. Active stabilization of ion trap radiofrequency potentials

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, K. G.; Wong-Campos, J. D.; Restelli, A.; Landsman, K. A.; Neyenhuis, B.; Mizrahi, J.; Monroe, C. [Joint Quantum Institute and University of Maryland Department of Physics, College Park, Maryland 20742 (United States)

    2016-05-15

    We actively stabilize the harmonic oscillation frequency of a laser-cooled atomic ion confined in a radiofrequency (rf) Paul trap by sampling and rectifying the high voltage rf applied to the trap electrodes. We are able to stabilize the 1 MHz atomic oscillation frequency to be better than 10 Hz or 10 ppm. This represents a suppression of ambient noise on the rf circuit by 34 dB. This technique could impact the sensitivity of ion trap mass spectrometry and the fidelity of quantum operations in ion trap quantum information applications.

  14. Ion transmission in a linear radiofrequency spectrometer

    International Nuclear Information System (INIS)

    Gomet, J.-C.

    1975-01-01

    A linear radiofrequency spectrometer is used for the purpose of experimental determination of the absolute ionization cross sections of various ions obtained by electron impact on polyatomic molecules. The transmission of the apparatus is studied: it does not only depend on the mass resolution of the spectrometer, but also on the nature of ions. It is affected by charge transfers, especially for the parent ions. An empiric way of correction of the apparatus function is given which allows the use at 10 -6 Torr [fr

  15. Radiofrequency Energy and Electrode Proximity Influences Stereoelectroencephalography-Guided Radiofrequency Thermocoagulation Lesion Size: An In Vitro Study with Clinical Correlation.

    Science.gov (United States)

    Staudt, Michael D; Maturu, Sarita; Miller, Jonathan P

    2018-02-16

    Radiofrequency thermocoagulation of epileptogenic foci via stereoelectroencephalography (SEEG) electrodes has been suggested as a treatment for medically intractable epilepsy, but reported outcomes have been suboptimal, possibly because lesions generated using conventional high-energy radiofrequency parameters are relatively small. To describe a technique of delivering low energy across separate SEEG electrodes in order to create large confluent radiofrequency lesions. The size and configuration of radiofrequency lesions using different radiofrequency intensity and interelectrode distance was assessed in egg whites. Magnetic resonance images (MRI) from 3 patients who had undergone radiofrequency lesion creation were evaluated to determine the contribution of lesion intensity and electrode separation on lesion size. Electroencephalography, MRI, and clinical data were assessed before and after lesion creation. Both in Vitro and in Vivo analysis revealed that less energy paradoxically produced larger lesions, with the largest possible lesions produced when radiofrequency power was applied for long duration at less than 3 W. Linear separation of electrodes also contributed to lesion size, with largest lesions produced when electrodes were separated by a linear distance of between 5 and 12 mm. Clinical lesions produced using these parameters were large and resulted in improvement in interictal and ictal activity. Radiofrequency lesions produced using low-energy delivery between SEEG electrodes in close proximity can produce a large lesion. These findings might have advantages for treatment of focal epilepsy.

  16. Alpha Emitting Radionuclides and Radiopharmaceuticals for Therapy

    International Nuclear Information System (INIS)

    Chérel, Michel; Barbet, Jacques

    2013-01-01

    Today, cancer treatments mainly rely on surgery or external beam radiation to remove or destroy bulky tumors. Chemotherapy is given when tumours cannot be removed or when dissemination is suspected. However, these approaches cannot permanently treat all cancers and relapse occurs in up to 50% of the patients’ population. Radioimmunotherapy (RIT) and peptide receptor radionuclide therapy (PRRT) are effective against some disseminated and metastatic diseases, although they are rarely curative. Most preclinical and clinical developments in this field have involved electron-emitting radionuclides, particularly iodine-131, yttrium-90 and lutetium-177. The large range of the electrons emitted by these radionuclides reduces their efficacy against very small tumour cell clusters or isolated tumour cells present in residual disease and in many haematological tumours (leukaemia, myeloma). The range of alpha particles in biological tissues is very short, less than 0.1 mm, which makes alpha emitters theoretically ideal for treatment of such isolated tumour cells or micro-clusters of malignant cells. Thus, over the last decade, a growing interest for the use of alpha-emitting radionuclides has emerged. Research on targeted alpha therapy (TAT) began years ago in Nantes through cooperation between Subatech, a nuclear physics laboratory, CRCNA, a cancer research centre with a nuclear oncology team and ITU (Karlsruhe, Germany). CD138 was demonstrated as a potential target antigen for Multiple Myeloma, which is a target of huge clinical interest particularly suited for TAT because of the disseminated nature of the disease consisting primarily of isolated cells and small clusters of tumour cells mainly localized in the bone marrow. Thus anti-CD138 antibodies were labelled with bismuth-213 from actinium-225/bismuth-213 generators provided by ITU and used to target multiple myeloma cells. In vitro studies showed cell cycle arrest, synergism with chemotherapy and very little induction

  17. Code of practice for safety in laboratory - non ionising radiation

    International Nuclear Information System (INIS)

    Ramli Jaya; Mohd Yusof Mohd Ali; Khoo Boo Huat; Khatijah Hashim

    1995-01-01

    The code identifies the non-ionizing radiation encountered in laboratories and the associated hazards. The code is intended as a laboratory standard reference document for general information on safety requirements relating to the usage of non-ionizing radiations in laboratories. The nonionizing radiations cover in this code, namely, are ultraviolet radiation, visible light, radio-frequency radiation, lasers, sound waves and ultrasonic radiation. (author)

  18. Analysis of public perception of increased radiofrequency exposure from mobile phone in Southwestern Nigeria

    International Nuclear Information System (INIS)

    Oladapo, O.O.; Ishola, G.A.; Ayokunnnu, D.O.

    2011-01-01

    Wireless communication devices have been increasingly used recently in Nigeria with a corresponding public perception of increase in radiofrequency (RF) radiation. This perception has developed into public concerns, thus requiring verification. For the purpose of verification, a survey in form of an opinion poll was conducted by means of an interview using questionnaires. The survey shows that people actually experienced symptoms like headache, fatigue, dizziness, and heat sensation. However, out of the respondents that have experienced one symptoms or the other, 84% still believe it is safe to use mobile phones. Only 4 % of those that claimed they experienced symptoms had consulted a doctor in connection with the symptoms.

  19. Radiation safety

    International Nuclear Information System (INIS)

    Jain, Priyanka

    2014-01-01

    The use of radiation sources is a privilege; in order to retain the privilege, all persons who use sources of radiation must follow policies and procedures for their safe and legal use. The purpose of this poster is to describe the policies and procedures of the Radiation Protection Program. Specific conditions of radiation safety require the establishment of peer committees to evaluate proposals for the use of radionuclides, the appointment of a radiation safety officer, and the implementation of a radiation safety program. In addition, the University and Medical Centre administrations have determined that the use of radiation producing machines and non-ionizing radiation sources shall be included in the radiation safety program. These Radiation Safety policies are intended to ensure that such use is in accordance with applicable State and Federal regulations and accepted standards as directed towards the protection of health and the minimization of hazard to life or property. It is the policy that all activities involving ionizing radiation or radiation emitting devices be conducted so as to keep hazards from radiation to a minimum. Persons involved in these activities are expected to comply fully with the Canadian Nuclear Safety Act and all it. The risk of prosecution by the Department of Health and Community Services exists if compliance with all applicable legislation is not fulfilled. (author)

  20. Cherenkov radiation

    International Nuclear Information System (INIS)

    Hubert, P.

    1955-01-01

    When the radioactivity has been discovered, it was observed by researchers that different materials as mineral salts or solutions were emitting a weak light when submitted to radioactivity beams. At the beginning it has been thought that it was fluorescent light. In 1934, Cherenkov, a russian physicist, worked on the luminescence of uranyl salts solutions caused by gamma radiation and observed a very weak light was emitted by pure liquid. After further studies, he concluded that this phenomena was different from fluorescence. Since then, it has been called Cherenkov effect. This blue light emission is produced when charged particles are going through a transparent medium with an upper velocity than light velocity. This can happen only in medium with large refractive index as water or glass. It also presents its different properties discovered afterwards. The different applications of the Cherenkov radiation are discussed as counting techniques for radiation detectors or comic ray detectors. (M.P.)

  1. USAFSAM Review and Analysis of Radiofrequency Radiation Bioeffects Literature.

    Science.gov (United States)

    1981-11-01

    less than 0.2 mW/cm . Clinical tests included ophthalmoscopic examination and a neurologic check-up supplemented by psychologic tests and EEG...34). These 12 studies are assessed individually and collectively below, followed by the analyses of each per se. Collective Summary In Lilienfeld et al...hours/workday). Electrocardiograms, heart and lung X-rays, eryth- rocyte sedimentation rates, urinalyses, and liver function tests were conducted as well

  2. Effect of Radiofrequency Radiation on DNA Duplex Stability and Replication.

    Science.gov (United States)

    1983-08-01

    Ando, T. A nuclease specific for heat-denatured DNA isolated from a product of Aspergillus oryzae . Biochim Biophys Acta 114:158-168 (1966). Blakeley...metabolic acti- vation. Mutation Res 64:315-328 (1979). Vogt,. V.M. Purification and further properties of single-strand-specific nuclease from Aspergillus oryzae . Eur J Biochem 33:192-200 (1973). 42

  3. Neurohumoral indicators of efficacy radiofrequency cardiac denervation

    Energy Technology Data Exchange (ETDEWEB)

    Evtushenko, A. V., E-mail: ave@cardio-tomsk.ru; Evtushenko, V. V. [National Research Tomsk State University, Tomsk (Russian Federation); Federal State Budgetary Scientific Institution “Research Institute for Cardiology”, Tomsk (Russian Federation); Saushkina, Yu. V.; Gusakova, A. M.; Suslova, T. E.; Dymbrylova, O. N.; Smyshlyaev, K. A.; Kurlov, I. O. [Federal State Budgetary Scientific Institution “Research Institute for Cardiology”, Tomsk (Russian Federation); Lishmanov, Yu. B.; Anfinogenova, Ya. D. [National Research Tomsk Polytechnic University, Tomsk (Russian Federation); Federal State Budgetary Scientific Institution “Research Institute for Cardiology”, Tomsk (Russian Federation); Sergeevichev, D. S. [Academician E.N. Meshalkin State Research Institute of Circulation Pathology, Novosibirsk (Russian Federation); Bykov, A. N.; Syryamkin, V. I.; Kistenev, Yu. V. [National Research Tomsk State University, Tomsk (Russian Federation); Lotkov, A. I. [Institute of Strength Physics and Materials Science of the Siberian Branch of the RAS, Tomsk (Russian Federation); Pokushalov, E. A.

    2015-11-17

    In this study, we compared pre- and postoperative parameters of the cardiac sympathetic innervation. The aim of the study was to examine the approaches to evaluating the quality of radiofrequency (RF)-induced cardiac denervation by using non-invasive and laboratory methods. The study included 32 people with long-lasting persistent atrial fibrillation (AF). The patients were divided into 2 groups according to the objectives of the study: group 1 (main) - 21 patients with mitral valve diseases, which simultaneously with radiofrequency ablation (RFA) AF carried out on the effects of the paraganglionic nervous plexuses by C. Pappone (2004) and N. Doll (2008) schemes. The second group (control) contained 11 patients with heart diseases in sinus rhythm (the RF denervation not been performed). All patients, who underwent surgical treatment, were received examination of cardiac sympathetic tone by using {sup 123}I-MIBG. All of them made blood analysis from ascending aorta and coronary sinus to determine the level of norepinephrine and its metabolites before and after cardiac denervation. Data of radionuclide examination are correlating with laboratory data.

  4. Radiofrequency spark chambers and delay line resonators

    International Nuclear Information System (INIS)

    Sayag, Jacques

    1971-01-01

    According to a suggestion of A. Kastler, a spark chamber was excited by an undamped radiofrequency pulse and tracks about 1 mm wide obtained; the result was interpreted by computation of the coefficients of electronic amplification and partial ambipolar diffusion. This work led us to the construction of a new fast triggering undamped wave-train generator of very high tension (patent taken out by the C.E.A. under the no.: EN 7 134 650 the 27.9.1971). Since this apparatus uses a resonant storage line, its design implied a precise knowledge of high impedance delay lines. The experimental radiofrequency spectra of the input impedance of opened or short-circuited lines were plotted completely and analysed by the circuits theory, new measuring methods were established, dispersion relations accurately checked and the equivalence of the formulas, within the third order, with theses of Debye's Dipolar Absorption demonstrated. General properties of Hilbert's transform were also investigated. From the experimental point of view, the electromagnetic energy storage process was extended to the case of a liquid nitrogen-immersed resonant delay line. The good behavior of the cryogenic experiment, where the main difficulty of icing was overcame by the construction of special electrodes, offers great promise for extrapolation to superconductivity. (author) [fr

  5. A sheath model for arbitrary radiofrequency waveforms

    Science.gov (United States)

    Turner, M. M.; Chabert, Pascal

    2012-10-01

    The sheath is often the most important region of a rf plasma, because discharge impedance, power absorption and ion acceleration are critically affected by the behaviour of the sheath. Consequently, models of the sheath are central to any understanding of the physics of rf plasmas. Lieberman has supplied an analytical model for a radio-frequency sheath driven by a single frequency, but in recent years interest has been increasing in radio-frequency discharges excited by increasingly complex wave forms. There has been limited success in generalizing the Lieberman model in this direction, because of mathematical complexities. So there is essentially no sheath model available to describe many modern experiments. In this paper we present a new analytical sheath model, based on a simpler mathematical framework than that of Lieberman. For the single frequency case, this model yields scaling laws that are identical in form to those of Lieberman, differing only by numerical coefficients close to one. However, the new model may be straightforwardly solved for arbitrary current waveforms, and may be used to derive scaling laws for such complex waveforms. In this paper, we will describe the model and present some illustrative examples.

  6. Bioeffects and health risks of low-level exposures to radiofrequency and microwave fields-scientific facts and public concerns

    International Nuclear Information System (INIS)

    Szmigielski, Stanislaw

    2001-01-01

    Radiofrequency (RF) and microwave (MW) radiations, parts of the electromagnetic spectrum at wave frequencies of 0.1 - 300 MHz and 300 MHz - 300 GHz, respectively, can penetrate human tissues and exert various bioeffects at relatively low field power densities. Exposure of the general public to RF/MW radiation in the environment is generally below intensities which are considered as responsible for evoking such bioeffects. Use of mobile phones (MP) considerably increased local exposure to 900 or 1800 MHz MWs and raised concerns of the risk of brain tumors and other neoplasms of the head. At present the experimental and epidemiological bulk of evidence is too limited for valid assessment of the risks. Health consequences of long-term use of MPs are not known in detail, but available data indicate that development of non-specific health symptoms is possible, at least in 'MW-hypersensitive' subjects. In contrast to cellular terminals, which emit locally relatively high intensity MW fields, transmitting antennas and base stations contribute to MW environmental contaminations only with a small portion of the energy and do not pose established health risks. Two available epidemiological studies of brain cancer morbidity in MP users did not confirm an increased risk for all types of neoplasms, but unexplained excesses of particular types and/or locations of the tumors has been reported. Experimental investigations revealed the possibility of epigenetic activity of certain MW exposures (frequently limited to particular frequencies and/or modulations of the carrier wave), but there exists no satisfactory support from epidemiological studies for the increased cancer risk in MW-exposed subjects. However, there exist single epidemiological studies which indicate increased mortality of certain types of neoplasms in workers exposed to microwave radiation. As an example, the multiyear study of cancer morbidity in Polish military personnel exposed to 2 - 10 W/m2 will be presented

  7. Radiofrequency exposure amongst employees of mobile network operators and broadcasters

    International Nuclear Information System (INIS)

    Litchfield, Ian; Sorahan, Tom; Tongeren, Martie van

    2017-01-01

    Little is known about personal exposure to radiofrequency (RF) fields amongst employees in the telecommunications industry responsible for installing and maintaining transmitters. IARC classified RF exposure as a possible carcinogen, although evidence from occupational studies was judged to be inadequate. Hence, there is a need for improved evidence of any potentially adverse health effects amongst the workforce occupationally exposed to RF radiation. In this study, results are presented from an exposure survey using data from personal monitors used by employees in the broadcasting and telecommunication industries of the UK. These data were supplemented by spot measurements using broadband survey metres and information on daily work activities provided by employee questionnaires. The sets of real-time personal data were categorised by four types of site determined by the highest powered antenna present (high, medium or low power and ground-level sites). For measurements gathered at each type of site, the root mean square and a series of box plots were produced. Results from the daily activities diaries suggested that riggers working for radio and television broadcasters were exposed to much longer periods as compared to colleagues working for mobile operators. Combining the results from the measurements and daily activity diaries clearly demonstrate that exposures were highest for riggers working for broadcasting sites. This study demonstrates that it is feasible to carry out exposure surveys within these populations that will provide reliable estimates of exposure that can be used for epidemiological studies of occupational groups exposed to RF fields. (authors)

  8. Radiofrequency Ablation for Early-Stage Nonsmall Cell Lung Cancer

    Directory of Open Access Journals (Sweden)

    Takao Hiraki

    2014-01-01

    Full Text Available This review examines studies of radiofrequency ablation (RFA of nonsmall cell lung cancer (NSCLC and discusses the role of RFA in treatment of early-stage NSCLC. RFA is usually performed under local anesthesia with computed tomography guidance. RFA-associated mortality, while being rare, can result from pulmonary events. RFA causes pneumothorax in up to 63% of cases, although pneumothorax requiring chest drainage occurs in less than 15% of procedures. Other severe complications are rare. After RFA of stage I NSCLC, 31–42% of patients show local progression. The 1-, 2-, 3-, and 5-year overall survival rates after RFA of stage I NSCLC were 78% to 100%, 53% to 86%, 36% to 88%, and 25% to 61%, respectively. The median survival time ranged from 29 to 67 months. The 1-, 2-, and 3-year cancer-specific survival rates after RFA of stage I NSCLC were 89% to 100%, 92% to 93%, and 59% to 88%, respectively. RFA has a higher local failure rate than sublobar resection and stereotactic body radiation therapy (SBRT. Therefore, RFA may currently be reserved for early-stage NSCLC patients who are unfit for sublobar resection or SBRT. Various technologies are being developed to improve clinical outcomes of RFA for early-stage NSCLC.

  9. Cherenkov radiation; La radiation Cerenkov

    Energy Technology Data Exchange (ETDEWEB)

    Hubert, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1955-07-01

    When the radioactivity has been discovered, it was observed by researchers that different materials as mineral salts or solutions were emitting a weak light when submitted to radioactivity beams. At the beginning it has been thought that it was fluorescent light. In 1934, Cherenkov, a russian physicist, worked on the luminescence of uranyl salts solutions caused by gamma radiation and observed a very weak light was emitted by pure liquid. After further studies, he concluded that this phenomena was different from fluorescence. Since then, it has been called Cherenkov effect. This blue light emission is produced when charged particles are going through a transparent medium with an upper velocity than light velocity. This can happen only in medium with large refractive index as water or glass. It also presents its different properties discovered afterwards. The different applications of the Cherenkov radiation are discussed as counting techniques for radiation detectors or comic ray detectors. (M.P.)

  10. High Intensity Organic Light-emitting Diodes

    Science.gov (United States)

    Qi, Xiangfei

    This thesis is dedicated to the fabrication, modeling, and characterization to achieve high efficiency organic light-emitting diodes (OLEDs) for illumination applications. Compared to conventional lighting sources, OLEDs enabled the direct conversion of electrical energy into light emission and have intrigued the world's lighting designers with the long-lasting, highly efficient illumination. We begin with a brief overview of organic technology, from basic organic semiconductor physics, to its application in optoelectronics, i.e. light-emitting diodes, photovoltaics, photodetectors and thin-film transistors. Due to the importance of phosphorescent materials, we will focus on the photophysics of metal complexes that is central to high efficiency OLED technology, followed by a transient study to examine the radiative decay dynamics in a series of phosphorescent platinum binuclear complexes. The major theme of this thesis is the design and optimization of a novel architecture where individual red, green and blue phosphorescent OLEDs are vertically stacked and electrically interconnected by the compound charge generation layers. We modeled carrier generation from the metal-oxide/doped organic interface based on a thermally assisted tunneling mechanism. The model provides insights to the optimization of a stacked OLED from both electrical and optical point of view. To realize the high intensity white lighting source, the efficient removal of heat is of a particular concern, especially in large-area devices. A fundamental transfer matrix analysis is introduced to predict the thermal properties in the devices. The analysis employs Laplace transforms to determine the response of the system to the combined effects of conduction, convection, and radiation. This perspective of constructing transmission matrices greatly facilitates the calculation of transient coupled heat transfer in a general multi-layer composite. It converts differential equations to algebraic forms, and

  11. Image-guided radiofrequency ablation of renal cell carcinoma

    International Nuclear Information System (INIS)

    Boss, Andreas; Clasen, Stephan; Pereira, Philippe L.; Kuczyk, Markus; Schick, Fritz

    2007-01-01

    The incidence of renal cell carcinoma is rising with the increased number of incidental detection of small tumours. During the past few years, percutaneous imaging-guided radiofrequency ablation has evolved as a minimally invasive treatment of small unresectable renal tumours offering reduced patient morbidity and overall health care costs. In radiofrequency ablation, thermal energy is deposited into a targeted tumour by means of a radiofrequency applicator. In recent studies, radiofrequency ablation was shown to be an effective and safe modality for local destruction of renal cell carcinoma. Radiofrequency applicator navigation can be performed via ultrasound, computed tomography or magnetic resonance guidance; however, ultrasound seems less favourable because of the absence of monitoring capabilities during ablation. On-line monitoring of treatment outcome can only be performed with magnetic resonance imaging giving the possibility of eventual applicator repositioning to ablate visible residual tumour tissue. Long-term follow-up is crucial to assess completeness of tumour ablation. New developments in ablation technology and radiological equipment will further increase the indication field for radiofrequency ablation of renal cell carcinoma. Altogether, radiofrequency ablation seems to be a promising new modality for the minimally invasive treatment of renal cell carcinoma, which was demonstrated to exhibit high short-term effectiveness. (orig.)

  12. Ring cavity surface emitting semiconductor lasers

    International Nuclear Information System (INIS)

    Mujagic, E.

    2010-01-01

    Quantum cascade lasers (QCLs) are electrically driven semiconductor lasers, which have undergone a steady improvement since the first demonstration in 1994. These are now well established as reliable sources of coherent light in the mid-infrared (MIR) and terahertz (THz)range of the electromagnetic spectrum (3-300 μm). The rapid progress of this type of lasers is based on a high degree of freedom in tailoring the emission wavelength within a large variety of semiconductor heterostructure designs and materials. These properties have attracted the attention of various applications such as gas analysis, chemical sensing, spectral imaging and free-space telecommunication. In order to improve the selectivity, sensitivity and efficiency of today's sensor systems, high optical power, continuous wave and room temperature performance, single-mode operation and low divergence optical beams, are highly desirable qualities of a compact laser source in this field of research. Since all of these features cannot be provided by a conventional edge-emitting device at the same time, research has put focus on the development of surface emitting devices. Nowadays, the vertical cavity surface emitting lasers (VCSELs) are the most prominent representative for this type of light emitters. With its capability of producing narrow circular beams, the feasibility of two-dimensional arrays and on-wafer testing, such a coherent light source results in a reduction of the fabrication effort and production costs. Since the radiation in QCLs is strictly polarized normal to the epitaxial layer plane, fabrication of VCSELs based on QC structures is not viable. The subject of this work is the design and realization of 'ring cavity surface emitting lasers' (ring-CSELs). This type of lasers employs a circular ring cavity and a resonant distributed feedback (DFB) surface grating. Ring-CSELs were fabricated on the basis of MIR and THz QC structures, which cover a wavelength range from 4 μm to 93

  13. Positron emitting radionuclides for South Africa

    International Nuclear Information System (INIS)

    Wynchbank, S.; Van der Walt, T.N.; Sharpey-Shafer, J.

    2004-01-01

    Full text: In South Africa there are currently two projects underway to supply and utilise positron emitting radionuclides for imaging in clinical nuclear medicine facilities. The advantages and applications of such radio nuclides are numerous and well known. However the premier initial application will be to employ 1BF, at first in the compound fluorine-18 fluorodeoxyglucose ( 18 F)-FDG, for patients with cancers and neoplasms. The two projects are sited at iThemba LABS, where production of a generator supplying 66 Ga and the provision of ( 18 F]-FDG, are in an advanced state of planning; the former already fully financed by the Innovation Fund of the National Research Foundation. The two positron emitting radionuclides, 18 F and 68 Ge, will be produced using a cyclotron induced reaction on 1802 and Ga, respectively, at iThemba LABS. The 68 Ge/ 68 Ga generator consists of an anion exchanger loaded with 68 Ge, which decays to 68 Ga. The resulting radiopharmaceuticals, ( 18 F]-FDG and 68 Ga citrate, will be produced by the Radionuclide Production Group of iThemba LABS, using well described methods. However the structures and processes to be used in the generator to provide 68 Ga are novel and will be explained. Initially provision of the CBF]-FDG will be to selected clinical medicine facilities in the Western Cape and Gauteng. It should be noted that the logistical problems of providing this radiopharmaceutical (which are much complicated by its short half life of 109.7 min) to Gauteng, were shown to be surmountable in the 1970s, by a regular delivery of 18 F between Gauteng and Cape Town, after the advent of a commercial service using jet aircraft. The obvious requirement that there should be appropriate nuclear medicine facilities to image patients, at the sites to which the positron emitting radiopharmaceuticals will be supplied, has been addressed. Proposed solutions will be outlined, in terms of a dedicated positron emission tomography (PET) camera and a gamma

  14. Hybrid Light-Emitting Diode Enhanced With Emissive Nanocrystals

    DEFF Research Database (Denmark)

    Kopylov, Oleksii

    This thesis investigates a new type of white light emitting hybrid diode, composed of a light emitting GaN/InGaN LED and a layer of semiconductor nanocrystals for color conversion. Unlike standard white LEDs, the device is configured to achieve high color conversion efficiency via non-radiative e......This thesis investigates a new type of white light emitting hybrid diode, composed of a light emitting GaN/InGaN LED and a layer of semiconductor nanocrystals for color conversion. Unlike standard white LEDs, the device is configured to achieve high color conversion efficiency via non...... of the hybrid diode fabrication including process techniques for GaN LED and incorporation of the nanocrystals are presented with the emphasis on the differences with standard LED processing. Results and analysis of optical and electrical characterization including photoluminescence (PL), micro-PL, time......-resolved PL and electroluminescence (EL) together with current-voltage characteristics are presented to evaluate the device performance. A clear evidence of non-radiative energy transfer was seen in the carrier dynamics of both the LED and the nanocrystals when the quantum well – nanocrystals separation...

  15. Clinical application and developmental trend of radiofrequency ablation technology

    International Nuclear Information System (INIS)

    Chen Dongfeng

    2009-01-01

    For recent two decades, radiofrequency ablation technology has made great progress in the field of the treatment for neoplasm. At the very beginning, radiofrequency ablation was adopted in treating the hepatic carcinoma, and since then it has been gradually practiced in treating malignancies of lung, bone, kidney, breast, prostate and other solid tumors. Statistical report of the year 2008 has indicated that in the aspect of similar therapeutic measures radiofrequency ablation therapy for tumors holds a 9% market share. Moreover, in the coming years the clinical use of this kind of therapy for tumors will be steadily increasing by 13% every year. (authors)

  16. Effects of the Effect of Ultra High Frequency Mobile Phone Radiation on Human Health.

    Science.gov (United States)

    Moradi, Mosa; Naghdi, Nasrollah; Hemmati, Hamidreza; Asadi-Samani, Majid; Bahmani, Mahmoud

    2016-05-01

    Public and occupational exposure to electromagnetic fields due to the growing trend of electronic devices may cause adverse effects on human health. This paper describes the risk of mutation and sexual trauma and infertility in masculine sexual cell by mobile phone radiations. In this study, we measured the emitted dose from a radiofrequency device, such as switching high voltage at different frequencies using a scintillation detector. The switching high voltage power supply (HVPS) was built for the Single Photon Emission Computed Tomography (SPECT) system. For radiation dosimetry, we used an ALNOR scintillator that can measure gamma radiation. The simulation was performed by MATLAB software, and data from the International Commission on Non-Ionizing Radiation Protection (ICNIRP) were used to verify the simulation. We investigated the risks that result from the waves, according to a report by International Commission on Non Ionizing Radiation Protection (ICNIRP), to every organ of the body is defined by the beam and electromagnetic radiation from this electronic device on people. The results showed that the maximum personal dose over a 15-min period working at the mentioned HVPS did not exceed 0.31 μSV/h (with an aluminum shield). So, according to other sources of radiation, continuous working time of the system should not be more than 10 hours. Finally, a characteristic curve for secure working with modules at different frequencies was reported. The RF input signal to the body for maximum penetration depth (δ) and electromagnetic energy absorption rate (SAR) of biological tissue were obtained for each tissue. The results of this study and International Commission of Non Ionization Radiation Protection (ICNIRP) reports showed the people who spend more than 50 minutes a day using a cell phone could have early dementia or other thermal damage due to the burning of glucose in the brain.

  17. Effect of Ultra High Frequency Mobile Phone Radiation on Human Health

    Science.gov (United States)

    Moradi, Mosa; Naghdi, Nasrollah; Hemmati, Hamidreza; Asadi-Samani, Majid; Bahmani, Mahmoud

    2016-01-01

    Introduction Public and occupational exposure to electromagnetic fields due to the growing trend of electronic devices may cause adverse effects on human health. This paper describes the risk of mutation and sexual trauma and infertility in masculine sexual cell by mobile phone radiations. Methods In this study, we measured the emitted dose from a radiofrequency device, such as switching high voltage at different frequencies using a scintillation detector. The switching high voltage power supply (HVPS) was built for the Single Photon Emission Computed Tomography (SPECT) system. For radiation dosimetry, we used an ALNOR scintillator that can measure gamma radiation. The simulation was performed by MATLAB software, and data from the International Commission on Non-Ionizing Radiation Protection (ICNIRP) were used to verify the simulation. Results We investigated the risks that result from the waves, according to a report by International Commission on Non Ionizing Radiation Protection (ICNIRP), to every organ of the body is defined by the beam and electromagnetic radiation from this electronic device on people. The results showed that the maximum personal dose over a 15-min period working at the mentioned HVPS did not exceed 0.31 μSV/h (with an aluminum shield). So, according to other sources of radiation, continuous working time of the system should not be more than 10 hours. Finally, a characteristic curve for secure working with modules at different frequencies was reported. The RF input signal to the body for maximum penetration depth (δ) and electromagnetic energy absorption rate (SAR) of biological tissue were obtained for each tissue. Conclusion The results of this study and International Commission of Non Ionization Radiation Protection (ICNIRP) reports showed the people who spend more than 50 minutes a day using a cell phone could have early dementia or other thermal damage due to the burning of glucose in the brain. PMID:27382458

  18. Shining light on radiation detection and energy transfer : Triazole ligands used for detection of radiation and lanthanide binding

    NARCIS (Netherlands)

    Dijkstra, Peter

    2016-01-01

    Some substances, fluorophores, absorb light and then emit that light again as fluorescence. Apart from absorption of light, some of these substances can also emit light after having absorbed energy from radiation. A substance which can absorb radiation and emit the energy as light is called a

  19. How I do it-optimizing radiofrequency ablation in spinal metastases using iCT and navigation.

    Science.gov (United States)

    Kavakebi, Pujan; Freyschlag, C F; Thomé, C

    2017-10-01

    Exact positioning of the radiofrequency ablation (RFA) probe for tumor treatment under fluoroscopic guidance can be difficult because of potentially small inaccessible lesions and the radiation dose to the medical staff in RFA. In addition, vertebroplasty (VP) can be significantly high. Description and workflow of RFA in spinal metastasis using iCT (intraoperative computed tomography) and 3D-navigation-based probe placement followed by VP. RFA and VP can be successfully combined with iCT-based navigation, which leads to a reduction of radiation to the staff and optimal probe positioning due to 3D navigation.

  20. Radiofrequency contact currents: sensory responses and dosimetry

    International Nuclear Information System (INIS)

    Kavet, Robert; Tell, R.A.; Olsen, R.G.

    2014-01-01

    The process of setting science-based exposure standards (or guidelines) for radiofrequency (RF) contact current exposure has been disadvantaged by a lack of relevant data. The authors first review the essential features and results of the available studies and illustrate the apparent discrepancies among them. Then, they examine the manner in which current was administered in these studies and suggest as to how the physical relationship of a contacting finger to the current electrode may play a role in affecting sensory thresholds specific to those configurations. A major factor in this analysis relates to whether current density is uniformly distributed across the contact area or whether an electrode's 'edge effects' enhance currents with a net effect of decreasing apparent thresholds, when expressed as the bulk current entering a subject. For an exposure with a clear hazard potential, thresholds of human sensory response to RF currents require further investigation. (authors)

  1. LAPAROSCOPIC NEPHRECTOMY USING RADIOFREQUENCY THERMAL ABLATION

    Directory of Open Access Journals (Sweden)

    B. Ya. Alekseev

    2012-01-01

    Full Text Available The wide use of current diagnostic techniques, such as ultrasound study, computed tomography, and magnetic resonance imaging, has led to significantly increased detection rates for disease in its early stages. This gave rise to a change in the standards for the treatment of locally advanced renal cell carcinoma (RCC. Laparoscopic nephrectomy (LN has recently become the standard treatment of locally advanced RCC in the clinics having much experience with laparoscopic surgery. The chief drawback of LN is difficulties in maintaining intraoperative hemostasis and a need for creating renal tissue ischemia. The paper gives the intermediate results of application of the new procedure of LN using radiofrequency thermal ablation in patients with non-ischemic early-stage RCC.

  2. Radiofrequency encoded angular-resolved light scattering

    DEFF Research Database (Denmark)

    Buckley, Brandon W.; Akbari, Najva; Diebold, Eric D.

    2015-01-01

    The sensitive, specific, and label-free classification of microscopic cells and organisms is one of the outstanding problems in biology. Today, instruments such as the flow cytometer use a combination of light scatter measurements at two distinct angles to infer the size and internal complexity...... of cells at rates of more than 10,000 per second. However, by examining the entire angular light scattering spectrum it is possible to classify cells with higher resolution and specificity. Current approaches to performing these angular spectrum measurements all have significant throughput limitations...... Encoded Angular-resolved Light Scattering (REALS), this technique multiplexes angular light scattering in the radiofrequency domain, such that a single photodetector captures the entire scattering spectrum from a particle over approximately 100 discrete incident angles on a single shot basis. As a proof...

  3. Optical generation of radio-frequency power

    International Nuclear Information System (INIS)

    Hietala, V.M.; Vawter, G.A.; Brennan, T.M.; Hammons, B.E.; Meyer, W.J.

    1994-11-01

    An optical technique for high-power radio-frequency (RF) signal generation is described. The technique uses a unique photodetector based on a traveling-wave design driven by an appropriately modulated light source. The traveling-wave photodetector (TWPD) exhibits simultaneously a theoretical quantum efficiency approaching 100 % and a very large electrical bandwidth. Additionally, it is capable of dissipating the high-power levels required for the RF generation technique. The modulated light source is formed by either the beating together of two lasers or by the direct modulation of a light source. A system example is given which predicts RF power levels of 100's of mW's at millimeter wave frequencies with a theoretical ''wall-plug'' efficiency approaching 34%

  4. Radiofrequency identification for inventory in neurointerventional practice.

    Science.gov (United States)

    Byers, Ernest; Gomez, Max A; Sheridan, Robert M; Orr, Nelson W; Hirsch, Joshua A

    2011-03-01

    Implementations of radiofrequency identification (RFID) systems within hospital settings are not unique or without controversy. To date, little consideration has been given to use of this technology in clinical interventional radiologic practice. The potential financial advantages coupled with benefits to quality and safety and increases in staff satisfaction are considerable. The authors outline these advantages by enabling readers to broadly consider the systemic perspective of implementing RFID technology with an associated vision toward downstream growth. Furthermore, the authors demonstrate the benefits of RFID technology integration in reducing cost and increasing quality assurance and the on-time delivery of services. Implementing RFID requires commitment from frontline technologist staff members to work collaboratively with management and external vendors. Ultimately, the authors believe this technology can positively influence patient care. Copyright © 2011 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  5. Radiofrequency Electromagnetic Field Map of Timisoara

    Science.gov (United States)

    Stefu, N.; Solyom, I.; Arama, A.

    2015-12-01

    There are many electromagnetic field (EMF) sources nowadays acting simultaneously, especially in urban areas, making the theoretical estimation of electromagnetic power at ground level very difficult. This paper reports on EMF maps built with measurements collected in Timisoara, at various radiofrequencies. A grid of 15×15 squares was built (approximate resolution 400m x 400m) and measurements of the average and maximum values of the electric field E, magnetic field H and total power density S at 0.9, 1.8 and 2.4 GHz were collected in every node of the grid. Positions of the nodes in terms of latitude and longitude were also collected. Maps were built presenting the spatial distribution of the measured quantities over Timisoara. Potential influences of EMF on public health are discussed.

  6. Radio-frequency quadrupole linear accelerator

    International Nuclear Information System (INIS)

    Wangler, T.P.; Stokes, R.H.

    1980-01-01

    The radio-frequency quadrupole (RFQ) is a new linear accelerator concept in which rf electric fields are used to focus, bunch, and accelerate the beam. Because the RFQ can provide strong focusing at low velocities, it can capture a high-current dc ion beam from a low-voltage source and accelerate it to an energy of 1 MeV/nucleon within a distance of a few meters. A recent experimental test at the Los Alamos Scientific Laboratory (LASL) has confirmed the expected performance of this structure and has stimulated interest in a wide variety of applications. The general properties of the RFQ are reviewed and examples of applications of this new accelerator are presented

  7. Anthropogenic radiofrequency electromagnetic fields as an emerging threat to wildlife orientation

    International Nuclear Information System (INIS)

    Balmori, Alfonso

    2015-01-01

    The rate of scientific activity regarding the effects of anthropogenic electromagnetic radiation in the radiofrequency (RF) range on animals and plants has been small despite the fact that this topic is relevant to the fields of experimental biology, ecology and conservation due to its remarkable expansion over the past 20 years. Current evidence indicates that exposure at levels that are found in the environment (in urban areas and near base stations) may particularly alter the receptor organs to orient in the magnetic field of the earth. These results could have important implications for migratory birds and insects, especially in urban areas, but could also apply to birds and insects in natural and protected areas where there are powerful base station emitters of radiofrequencies. Therefore, more research on the effects of electromagnetic radiation in nature is needed to investigate this emerging threat. - Highlights: • The growth of wireless telecommunication technologies causes increased electrosmog. • Radio frequency fields in the MHz range disrupt insect and bird orientation. • Radio frequency noise interferes with the primary process of magnetoreception. • Existing guidelines do not adequately protect wildlife. • Further research in this area is urgent

  8. Anthropogenic radiofrequency electromagnetic fields as an emerging threat to wildlife orientation

    Energy Technology Data Exchange (ETDEWEB)

    Balmori, Alfonso, E-mail: balmaral@jcyl.es

    2015-06-15

    The rate of scientific activity regarding the effects of anthropogenic electromagnetic radiation in the radiofrequency (RF) range on animals and plants has been small despite the fact that this topic is relevant to the fields of experimental biology, ecology and conservation due to its remarkable expansion over the past 20 years. Current evidence indicates that exposure at levels that are found in the environment (in urban areas and near base stations) may particularly alter the receptor organs to orient in the magnetic field of the earth. These results could have important implications for migratory birds and insects, especially in urban areas, but could also apply to birds and insects in natural and protected areas where there are powerful base station emitters of radiofrequencies. Therefore, more research on the effects of electromagnetic radiation in nature is needed to investigate this emerging threat. - Highlights: • The growth of wireless telecommunication technologies causes increased electrosmog. • Radio frequency fields in the MHz range disrupt insect and bird orientation. • Radio frequency noise interferes with the primary process of magnetoreception. • Existing guidelines do not adequately protect wildlife. • Further research in this area is urgent.

  9. Radio-frequency wave enhanced runaway production rate

    International Nuclear Information System (INIS)

    Chan, V.S.; McClain, F.W.

    1983-01-01

    Enhancement of runaway electron production (over that of an Ohmic discharge) can be achieved by the addition of radio-frequency waves. This effect is studied analytically and numerically using a two-dimensional Fokker--Planck quasilinear equation

  10. Ion-storage in radiofrequency electric quadrupole field

    International Nuclear Information System (INIS)

    Gheorghe, V.

    1976-01-01

    The confinement of charged particles in a quadrupole radiofrequency electric field are presented. The stability diagrams and phase space trajectories for the quadrupole mass spectrometer and for the ion trap are represented and their main characteristics are discussed. (author)

  11. Process for selected gas oxide removal by radiofrequency catalysts

    Science.gov (United States)

    Cha, Chang Y.

    1993-01-01

    This process to remove gas oxides from flue gas utilizes adsorption on a char bed subsequently followed by radiofrequency catalysis enhancing such removal through selected reactions. Common gas oxides include SO.sub.2 and NO.sub.x.

  12. Paying attention to radiofrequency ablation therapy for neoplasms

    International Nuclear Information System (INIS)

    Wang Zhongming; Li Linsun

    2010-01-01

    Radiofrequency ablation is an effective treatment for malignant tumors. With the development of imaging technique, it has been widely used in treating different kinds of malignant tumors, such as liver cancer, lung cancer, kidney carcinoma, etc. Radiofrequency ablation has a lot of advantages. As a minimally-invasive, safe and effective treatment with less sufferings and fewer complications, this technique has attracted more and more attention of the experts both at home and abroad. (authors)

  13. Saline-enhanced radiofrequency electrocoagulation in bovine liver

    International Nuclear Information System (INIS)

    Shin, Hong Seop; Oh, Joo Hyeong; Yoon, Yup; Kim, Hyun Cheol; Ko, Young Tae; Choi, Woo Suk; Lim, Joo Won; Kim, Eui Jong

    1997-01-01

    To determine the effectiveness of saline-enhanced radiofrequency electrocoagulation in bovine liver tissue Saline-enhanced radiofrequency electrocoagulation (group I), hot saline injection induced by radiofrequency electrocoagulation (group II), and radiofrequency electrocoagulation (group III) were performed in ex vivo bovine liver. Radiofrequency power was 100 and 200 watts, and current was applied for 10, 20, and 30 seconds. Tissue was histopathologically examined for thermal injury. The largest diameter of thermal injury was about 41.0 mm in group I, 12.3 mm in group II and 9.3 mm in group III. The mean diameter of the injury increased with higher wattage in group I and II and with longer procedure time in group I (p<0.05). At corresponding wattage and times, group I showed a larger diameter of thermal injury and more increase in than group II or III (p<0.05). The degree of carbonization was more severe in group III than in groups I and II. Grossly, thermal injury showed a well-defined, relatively spherical configuration without extension along parenchymal interstitium. In an animal model, saline-enhanced radiofrequency electrocoagulation may effectively induce thermal injury, and may thus be another effective tool for use in the treatment of hepatic tumors. Further clinical experience is needed

  14. Treatment of Refractory Idiopathic Supraorbital Neuralgia Using Percutaneous Pulsed Radiofrequency.

    Science.gov (United States)

    Luo, Fang; Lu, Jingjing; Ji, Nan

    2018-02-26

    No ideal therapeutic method currently exists for refractory idiopathic supraorbital neuralgia patients who do not respond to conservative therapy, including medications and nerve blocks. Pulsed radiofrequency is a neuromodulation technique that does not produce sequelae of nerve damage after treatment. However, the efficacy of percutaneous pulsed radiofrequency for the treatment of refractory idiopathic supraorbital neuralgia is still not clear. The purpose of our study was to evaluate the efficacy and safety of pulsed radiofrequency treatment of the supraorbital nerve for refractory supraorbital neuralgia patients. We prospectively investigated the long-term effects of ultrasound-guided percutaneous pulsed radiofrequency in the treatment of 22 refractory idiopathic supraorbital neuralgia patients. A reduction in the verbal pain numeric rating scale score of more than 50% was used as the standard of effectiveness. The effectiveness rates at different time points within 2 years were calculated. After a single pulsed radiofrequency treatment, the effectiveness rate at 1 and 3 months was 77%, and the rates at 6 months, 1 year, and 2 years were 73%, 64%, and 50%, respectively. Except for a small portion of patients (23%) who experienced mild upper eyelid ecchymosis that gradually disappeared after approximately 2 weeks, no obvious complications were observed. In conclusion, the results of our study demonstrate that for patients with refractory idiopathic supraorbital neuralgia, percutaneous pulsed radiofrequency may be an effective and safe treatment choice. © 2018 World Institute of Pain.

  15. Saline-enhanced radiofrequency electrocoagulation in bovine liver

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Hong Seop; Oh, Joo Hyeong; Yoon, Yup; Kim, Hyun Cheol; Ko, Young Tae; Choi, Woo Suk; Lim, Joo Won; Kim, Eui Jong [Kyunghee Univ. Hospital, Seoul (Korea, Republic of)

    1997-08-01

    To determine the effectiveness of saline-enhanced radiofrequency electrocoagulation in bovine liver tissue Saline-enhanced radiofrequency electrocoagulation (group I), hot saline injection induced by radiofrequency electrocoagulation (group II), and radiofrequency electrocoagulation (group III) were performed in ex vivo bovine liver. Radiofrequency power was 100 and 200 watts, and current was applied for 10, 20, and 30 seconds. Tissue was histopathologically examined for thermal injury. The largest diameter of thermal injury was about 41.0 mm in group I, 12.3 mm in group II and 9.3 mm in group III. The mean diameter of the injury increased with higher wattage in group I and II and with longer procedure time in group I (p<0.05). At corresponding wattage and times, group I showed a larger diameter of thermal injury and more increase in than group II or III (p<0.05). The degree of carbonization was more severe in group III than in groups I and II. Grossly, thermal injury showed a well-defined, relatively spherical configuration without extension along parenchymal interstitium. In an animal model, saline-enhanced radiofrequency electrocoagulation may effectively induce thermal injury, and may thus be another effective tool for use in the treatment of hepatic tumors. Further clinical experience is needed.

  16. GSM 900 MHz Microwave RadiationInduced Alterations of Insulin Level and Histopathological Changes of Liver and Pancreas in Rat

    Directory of Open Access Journals (Sweden)

    Mortazavi S. M. J.

    2016-12-01

    Full Text Available Background: The rapidly increasing use of mobile phones has led to public concerns about possible health effects of these popular communication devices. This study is an attempt to investigate the effects of radiofrequency (RF radiation produced by GSM mobile phones on the insulin release in rats. Methods: Forty two female adult Sprague Dawley rats were randomly divided into 4 groups. Group1 were exposed to RF radiation 6 hours per day for 7 days. Group 2 received sham exposure (6 hours per day for 7 days. Groups 3 and 4 received RF radiation 3 hours per day for 7 days and sham exposure (3 hours per day, respectively. The specific absorption rate (SAR of RF was 2.0W/kg. Results: Our results showed that RF radiations emitted from mobile phone could not alter insulin release in rats. However, mild to severe inflammatory changes in the portal spaces of the liver of rats as well as damage in the cells of islet of Langerhans were observed. These changes were linked with the duration of the exposures. Conclusion: RF exposure can induce inflammatory changes in the liver as well causing damage in the cells of islet of Langerhans.

  17. Conventional Radiofrequency Thermocoagulation vs Pulsed Radiofrequency Neuromodulation of Ganglion Impar in Chronic Perineal Pain of Nononcological Origin.

    Science.gov (United States)

    Usmani, Hammad; Dureja, G P; Andleeb, Roshan; Tauheed, Nazia; Asif, Naiyer

    2018-01-10

    Chronic nononcological perineal pain has been effectively managed by ganglion Impar block. Chemical neurolysis, cryoablation, and radiofrequency ablation have been the accepted methods of blockade. Recently, pulsed radiofrequency, a novel variant of conventional radiofrequency, has been used for this purpose. This was a prospective, randomized, double-blind study. Two different interventional pain management centers in India. To compare the efficacy of conventional radiofrequency and pulsed radiofrequency for gangliom Impar block. The patients were randomly allocated to one of two groups. In the conventional radiofrequency (CRF) group (N = 34), conventional radiofrequency ablation was done, and in the PRF pulsed radiofrequency (PRF) group (N = 31), pulsed radiofrequency ablation was done. After informed and written consent, fluoroscopy-guided ganglion Impar block was performed through the first intracoccygeal approach. The extent of pain relief was assessed by visual analog scale (VAS) at 24 hours, and at the first, third, and sixth weeks following the intervention. A questionnaire to evaluate subjective patient satisfaction was also used at each follow-up visit. In the CRF group, the mean VAS score decreased significantly from the baseline value at each follow-up visit. But in the PRF group, this decrease was insignificant except at 24-hour follow-up. Intergroup comparison also showed significantly better pain relief in the CRF group as compared with the PRF group. At the end of follow-up, 28 patients (82%) in the CRF group and four patients (13%) in the PRF group had excellent results, as assessed by the subjective patient satisfaction questionnaire. There was no complication in any patient of either study group, except for short-lived infection at the site of skin puncture in a few. Ganglion Impar block by conventional radiofrequency provided a significantly better quality of pain relief with no major side effects in patients with chronic

  18. Robot-assisted radiofrequency ablation of primary and secondary liver tumours: early experience

    International Nuclear Information System (INIS)

    Abdullah, Basri Johan Jeet; Yeong, Chai Hong; Goh, Khean Lee; Yoong, Boon Koon; Ho, Gwo Fuang; Yim, Carolyn Chue Wai; Kulkarni, Anjali

    2014-01-01

    Computed tomography (CT)-compatible robots, both commercial and research-based, have been developed with the intention of increasing the accuracy of needle placement and potentially improving the outcomes of therapies in addition to reducing clinical staff and patient exposure to radiation during CT fluoroscopy. In the case of highly inaccessible lesions that require multiple plane angulations, robotically assisted needles may improve biopsy access and targeted drug delivery therapy by avoidance of the straight line path of normal linear needles. We report our preliminary experience of performing radiofrequency ablation of the liver using a robotic-assisted CT guidance system on 11 patients (17 lesions). Robotic-assisted planning and needle placement appears to have high accuracy, is technically easier than the non-robotic-assisted procedure, and involves a significantly lower radiation dose to both patient and support staff. (orig.)

  19. Robot-assisted radiofrequency ablation of primary and secondary liver tumours: early experience

    Energy Technology Data Exchange (ETDEWEB)

    Abdullah, Basri Johan Jeet [University of Malaya, Department of Biomedical Imaging, Faculty of Medicine, Kuala Lumpur (Malaysia); Yeong, Chai Hong [University of Malaya, University of Malaya Research Imaging Centre, Faculty of Medicine, Kuala Lumpur (Malaysia); Goh, Khean Lee [University of Malaya, Department of Internal Medicine, Faculty of Medicine, Kuala Lumpur (Malaysia); Yoong, Boon Koon [University of Malaya, Department of Surgery, Faculty of Medicine, Kuala Lumpur (Malaysia); Ho, Gwo Fuang [University of Malaya, Department of Oncology, Faculty of Medicine, Kuala Lumpur (Malaysia); Yim, Carolyn Chue Wai [University of Malaya, Department of Anesthesia, Faculty of Medicine, Kuala Lumpur (Malaysia); Kulkarni, Anjali [Perfint Healthcare Corporation, Florence, OR (United States)

    2014-01-15

    Computed tomography (CT)-compatible robots, both commercial and research-based, have been developed with the intention of increasing the accuracy of needle placement and potentially improving the outcomes of therapies in addition to reducing clinical staff and patient exposure to radiation during CT fluoroscopy. In the case of highly inaccessible lesions that require multiple plane angulations, robotically assisted needles may improve biopsy access and targeted drug delivery therapy by avoidance of the straight line path of normal linear needles. We report our preliminary experience of performing radiofrequency ablation of the liver using a robotic-assisted CT guidance system on 11 patients (17 lesions). Robotic-assisted planning and needle placement appears to have high accuracy, is technically easier than the non-robotic-assisted procedure, and involves a significantly lower radiation dose to both patient and support staff. (orig.)

  20. Comparison of wet radiofrequency ablation with dry radiofrequency ablation and radiofrequency ablation using hypertonic saline preinjection: ex vivo bovine liver

    International Nuclear Information System (INIS)

    Lee, Jeong Min; Han, Joon Koo; Kim, Se Hyung; Lee, Jae Young; Park, Hee Sun; Hur, Hurn; Choi, Byung Ihn; Shin, Kyung Sook

    2004-01-01

    We wished to compare the in-vitro efficiency of wet radiofrequency (RF) ablation with the efficiency of dry RF ablation and RF ablation with preinjection of NaCl solutions using excised bovine liver. Radiofrequency was applied to excised bovine livers in a monopolar mode for 10 minutes using a 200 W generator and a perfused-cooled electrode with or without injection or slow infusion of NaCl solutions. After placing the perfused-cooled electrode in the explanted liver, 50 ablation zones were created with five different regimens: group A; standard dry RF ablation, group B; RF ablation with 11 mL of 5% NaCl solution preinjection, group C; RF ablation with infusion of 11 mL of 5% NaCl solution at a rate of 1 mL/min, group D; RFA with 6 mL of 36% NaCl solution preinjection, group E; RF ablation with infusion of 6 mL of 36% NaCl solution at a rate of 0.5 mL/min. In groups C and E, infusion of the NaCl solutions was started 1 min before RF ablation and then maintained during RF ablation (wet RF ablation). During RF ablation, we measured the tissue temperature at 15 mm from the electrode. The dimensions of the ablation zones and changes in impedance, current and liver temperature during RF ablation were then compared between the groups. With injection or infusion of NaCl solutions, the mean initial tissue impedance prior to RF ablation was significantly less in groups B, C, D, and E (43-75 Ω) than for group A (80 Ω) (ρ 3 in group A; 12.4 ± 3.8 cm 3 in group B; 80.9 ± 9.9 cm 3 in group C; 45.3 ± 11.3 cm 3 in group D and 81.6 ± 8.6 cm 3 in group E. The tissue temperature measured at 15 mm from the electrode was higher in groups C, D and E than other groups (ρ < 0.05): 53 ± 12 .deg. C in group A, 42 ± 2 .deg. C in group B, 93 ± 8 .deg. C in group C; 79 ± 12 .deg. C in group D and 83 ± 8 .deg.C in group E. Wet RF ablation with 5% or 36% NaCl solutions shows better efficiency in creating a large ablation zone than does dry RF ablation or RF ablation with

  1. Specification for symbol for ionizing radiation

    International Nuclear Information System (INIS)

    1974-01-01

    This Malaysia Standard specification specifies a symbol recommended for use only to signify the actual or potential presence of ionizing radiation (#betta#, α, #betta# only) and to identify objects, devices, materials or combinations of materials which emit such radiation. (author)

  2. Radiation dose electrophysiology procedures

    International Nuclear Information System (INIS)

    Hernandez-Armas, J.; Rodriguez, A.; Catalan, A.; Hernandez Armas, O.; Luque Japon, L.; Moral, S.; Barroso, L.; Rfuez-Hdez, R.

    2006-01-01

    The aim of this paper has been to measure and analyse some of the parameters which are directly related with the doses given to patients in two electrophysiology procedures: diagnosis and ablation with radiofrequency. 16 patients were considered in this study. 13 them had an ablation with radiofrequency at the Unit of Electrophysiology at the University Hospital of the Canaries, La Laguna., Tenerife. The results of skin doses, in the ablation cases, were higher than 2 Gy (threshold of some deterministic effects). The average value was 1.1 Gy. The personal doses, measured under the lead apron, for physician and nurses were 4 and 3 micro Sievert. These results emphasised the necessity of radiation protection measures in order to reduce, ad much as possible, the doses to patients. (Author)

  3. Electromagnetic radiation detector

    Science.gov (United States)

    Benson, Jay L.; Hansen, Gordon J.

    1976-01-01

    An electromagnetic radiation detector including a collimating window, a cathode member having a photoelectric emissive material surface angularly disposed to said window whereby radiation is impinged thereon at acute angles, an anode, separated from the cathode member by an evacuated space, for collecting photoelectrons emitted from the emissive cathode surface, and a negatively biased, high transmissive grid disposed between the cathode member and anode.

  4. CT-guided radiofrequency ablation of osteoid osteoma using a novel battery-powered drill

    Energy Technology Data Exchange (ETDEWEB)

    Schnapauff, Dirk; Streitparth, Florian; Wieners, Gero; Collettini, Federico; Hamm, Bernd; Gebauer, Bernhard [Charite Universitaetsmedizin Berlin, Department of Radiology, Berlin (Germany); Joehrens, Korinna [Charite Universitaetsmedizin Berlin, Department of Pathology, Berlin (Germany)

    2015-05-01

    To evaluate the use of a novel battery-powered drill, enabling specimen requirement while drilling, in radiofrequency ablation of osteoid osteoma as an alternative to conventional orthopedic drills. Between 2009 and 2013, altogether 33 patients underwent CT-guided radiofrequency ablation of an osteoid osteoma at our institution. To access the nidus of the clinically and radiologically suspected osteoid osteoma, a channel was drilled using the OnControl Bone Marrow Biopsy System (OBM, Arrow OnControl, Teleflex, Shavano Park, TX, USA) and a biopsy was taken. Procedure time (i.e., drilling including local anesthesia), amount of scans (i.e., single-shot fluoroscopy), radiation exposure, and the results of biopsy were investigated and compared retrospectively to a classical approach using either a manual bone biopsy system or a conventional orthopedic drill (n = 10) after ethical review board approval. Drilling the tract into the nidus was performed without problems in 22 of the 23 OBM cases. Median procedure time was 7 min compared to 13 min using the classical approach (p < 0.001). Median amount CT scans, performed to control correct positioning of the drill was comparable with 26 compared to 24.5 (p = NS) scans. Histologically, the diagnosis of osteoid osteomas could be determined in all 17 cases where a biopsy was taken. Radiofrequency ablation could be performed without problems in any case. The use of the battery-powered drill was feasible and facilitated the access to the osteoid osteoma's nidus offering the possibility to extract a specimen in the same step. (orig.)

  5. Radiofrequency Exposure Amongst Employees of Mobile Network Operators and Broadcasters.

    Science.gov (United States)

    Litchfield, Ian; van Tongeren, Martie; Sorahan, Tom

    2017-06-15

    Little is known about personal exposure to radiofrequency (RF) fields amongst employees in the telecommunications industry responsible for installing and maintaining transmitters. IARC classified RF exposure as a possible carcinogen, although evidence from occupational studies was judged to be inadequate. Hence, there is a need for improved evidence of any potentially adverse health effects amongst the workforce occupationally exposed to RF radiation. In this study, results are presented from an exposure survey using data from personal monitors used by employees in the broadcasting and telecommunication industries of the UK. These data were supplemented by spot measurements using broadband survey metres and information on daily work activities provided by employee questionnaires. The sets of real-time personal data were categorised by four types of site determined by the highest powered antenna present (high, medium or low power and ground-level sites). For measurements gathered at each type of site, the root mean square and a series of box plots were produced. Results from the daily activities diaries suggested that riggers working for radio and television broadcasters were exposed to much longer periods as compared to colleagues working for mobile operators. Combining the results from the measurements and daily activity diaries clearly demonstrate that exposures were highest for riggers working for broadcasting sites. This study demonstrates that it is feasible to carry out exposure surveys within these populations that will provide reliable estimates of exposure that can be used for epidemiological studies of occupational groups exposed to RF fields. © The Author 2016. Published by Oxford University Press.

  6. Research on internal dosimetry for some of gamma emitting nuclides for radiation workers by direct method (in-vivo) with using a chair-type whole-body counter

    International Nuclear Information System (INIS)

    Nguyen Van Hung; Pham Hung Thai

    2003-01-01

    This research objective is to establish a chair-type whole-body counter with using NaI(Ti) detector in large sizes and whole-body standard phantoms as well as to apply the computational program of LUDEP 2.0. Steel holder with a lead collimator, two whole-body standard phantoms in Vietnamese adults (one for male and another for female) by plastic material, electronic blocks of ADC and MCD (8K), MCA program for measuring gamma spectrum by VB6 language in Windows are established and made. In addition, applied research for the program of LUDEP 2.0 in order to calculate and evaluated internal doses for radiation workers is carried out. (author)

  7. Photodetector of ultraviolet radiation

    International Nuclear Information System (INIS)

    Dorogan, V.; Branzari, V.; Vieru, T.; Manole, M.; Canter, V.

    2000-01-01

    The invention relates to photodetectors on base of semiconductors of ultraviolet radiation and may be used in optoelectronic system for determining the intensity and the dose of ultraviolet radiation emitted by the Sun or other sources. Summary of the invention consists in the fact that in the photodetector of ultraviolet radiation the superficial potential barrier is divided into two identical elements, electrically isolated each of the other, one of them being covered with a layer of transparent material for visible and infrared radiation and absorption the ultra violet radiation. The technical result consists in mutual compensation of visible and infrared components of the radiation spectrum

  8. Percutaneous radiofrequency treatment for refractory anteromedial pain of osteoarthritic knees.

    Science.gov (United States)

    Ikeuchi, Masahiko; Ushida, Takahiro; Izumi, Masashi; Tani, Toshikazu

    2011-04-01

    Although severe knee osteoarthritis with refractory pain is commonly treated surgically, this is often not an option for patients with poor health status or unwillingness to undergo major surgery. We examined the efficacy of radiofrequency application to sensory nerves as a novel alternative treatment for refractory knee pain. This study was an open-label, nonrandomized, and controlled study. Patients complaining of refractory anteromedial knee pain associated with radiological osteoarthritis (moderate or severe) were included. They were assigned to one of two groups: those receiving radiofrequency thermocoagulation (N = 18) or those receiving nerve block (N = 17), depending on the time period that they were referred to the clinic. Radiofrequency current or local anesthetics was applied to the medial retinacular nerve and the infrapatellar branch of the saphenous nerve. Western Ontario McMaster Universities osteoarthritis index score, pain visual analog scale (VAS), and patient's global assessment were assessed with a minimum follow-up of 6 months.   Radiofrequency treatment significantly decreased knee pain as measured by VAS for 12 weeks compared with the control group. In terms of responders, more patients in the RF group responded to the treatment than in the control group. The differences were statistically significant at 4 weeks, 8 weeks, and 12 weeks in pain VAS. Eight patients (44%) treated with radiofrequency rated excellent or good but only three (18%) in the control group rated good, although the difference was not statistically significant. Some patients were able to benefit substantially from radiofrequency treatment. Even if its effective period is limited, radiofrequency application is a promising treatment to alleviate refractory anteromedial knee pain with osteoarthritis. Further experience and technical improvements are needed to establish its role in the management of knee osteoarthritis. Wiley Periodicals, Inc.

  9. Coherent radiation mechanism for cometary kilometric radiation

    International Nuclear Information System (INIS)

    Lakhina, G.S.; Buti, B.

    1988-01-01

    A mechanism involving nonlinear interaction of Alfven solitons and Langmuir waves is proposed to explain the cometary kilometric radiation (CKR) observed in the vicinity of comet Halley. According to this model, the frequency of the radiation emitted depends on the position of the interaction (or emission) region relative to the comet; higher frequencies being emitted when this region is closer to the comet. The CKR source is shown to lie at a distance ranging between 10 to the 5th and 2 x 10 to the 6th km from the comet nucleus. Several observed features of CKR, type D, S, and C emissions, can be explained nicely by this model. 24 references

  10. GaN-Based Multiple-Quantum-Well Light-Emitting Diodes Employing Nanotechnology for Photon Management

    KAUST Repository

    Hsiao, Yu Hsuan; Tsai, Meng Lin; He, Jr-Hau

    2015-01-01

    Nanostructures have been proved to be an efficient way of modifying/improving the performance of GaN-based light-emitting diodes (LEDs). The achievements in photon management include strain relaxation, light extraction enhancement, radiation pattern

  11. Synchrotron Radiation

    International Nuclear Information System (INIS)

    Asfour, F.I

    2000-01-01

    Synchrotron light is produced by electron accelerators combined with storage rings. This light is generated over a wide spectral region; from infra-red (IR) through the visible and vacuum ultraviolet (VUV), and into the X-ray region. For relativistic electrons (moving nearly with the speed of light), most radiation is concentrated in a small cone with an opening angle of 1/gamma(some 0.1 to 1 milliradian),where gamma is the electron energy in units of rest energy (typically 10 3 -10 4 ). In synchrotron radiation sources (storage rings) highly relativistic electrons are stored to travel along a circular path for many hours. Radiation is caused by transverse acceleration due to magnetic forces(bending magnets). The radiation is emitted in pulses of 10-20 picosecond, separated by some 2 nanosecond or longer separation

  12. Radio-Frequency Emissions from Streamer Collisions: Implications for High-Energy Processes.

    Science.gov (United States)

    Luque, A.

    2017-12-01

    The production of energetic particles in a discharge corona is possibly linked to the collision of streamers of opposite polarities [Cooray et al. (2009), Kochkin et al. (2012), Østgaard et al. (2016)]. There is also experimental evidence linking it to radio-frequency emissions in the UHF frequency range (300 MHz-3 GHz) [Montanyà et al. (2015), Petersen and Beasley (2014)]. Here we investigate these two links by modeling the radio-frequency emissions emanating from an encounter between two counter-propagating streamers. Our numerical model combines self-consistently a conservative, high-order Finite-Volume scheme for electron transport with a Finite-Difference Time-Domain (FDTD) method for electromagnetic propagation. We also include the most relevant reactions for streamer propagation: impact ionization, dissociative attachment and photo-ionization. Our implementation benefits from massive parallelization by running on a General-Purpose Graphical Processing Unit (GPGPU). With this code we found that streamer encounters emit electromagnetic waves predominantly in the UHF range, supporting the hypothesis that streamer collisions are essential precursors of high-energy processes in electric discharges. References Cooray, V., et al., J. Atm. Sol.-Terr. Phys., 71, 1890, doi:10.1016/j.jastp.2009.07.010 (2009). Kochkin, P. O., et al., J. Phys. D, 45, 425202, doi: 10.1088/0022-3727/45/42/425202 (2012). Montanyà, J., et al., J. Atm. Sol.-Terr. Phys., 136, 94, doi:10.1016/j.jastp.2015.06.009, (2015). Østgaard, N., et al., J. Geophys. Res. (Atmos.), 121, 2939, doi:10.1002/2015JD024394 (2016). Petersen, D., and W. Beasley, Atmospheric Research, 135, 314, doi:10.1016/j.atmosres.2013.02.006 (2014).

  13. Radiations from GSM Base Stations and its Biological Effects

    African Journals Online (AJOL)

    Michael Horsfall

    All rights reserved ... radiofrequency radiations on albino mice placed in exposure cages and ... information in Nigeria on the possible effects of the .... The slides were left to dry on the hot plate ... potential health effect of the RF radiations. It is also a pointer to the need for .... The telecommunication industry is an essential.

  14. Stepwise radiofrequency ablation of Barrett's esophagus preserves esophageal inner diameter, compliance, and motility

    NARCIS (Netherlands)

    Beaumont, H.; Gondrie, J. J.; McMahon, B. P.; Pouw, R. E.; Gregersen, H.; Bergman, J. J.; Boeckxstaens, G. E.

    2009-01-01

    Background and aim: Stepwise endoscopic circumferential and focal radiofrequency ablation is safe and effective for the eradication of Barrett's esophagus. In contrast to other techniques, radiofrequency ablation appears to avoid significant esophageal scarring or stenosis. Our aim was to evaluate

  15. Evaluation of radiofrequency dielectric heaters workers exposure

    International Nuclear Information System (INIS)

    Benes, M.; Del Frate, S.; Villalta, R.

    2008-01-01

    Radiofrequency dielectric heaters (RFDH) are widely used in the woodworking industry for gluing laminates by applying pressure and RF heating. The workers operating such equipment remain in the vicinity of the machinery all day and can therefore be exposed to considerable levels of electric and magnetic field at RFs. This work describes the method used to measure the strength of fields generated by this particular machinery. This procedure is based on current methods cited in the literature and introduces the necessary modifications to meet this specific case. In particular, as there is often a scarcity of technical data available relating to such heaters, it is suggested that a spectrum analyser be used for measurements in the frequencies domain. On the basis of the data obtained the norms of reference are established, the instrumentation to be used in successive stages determined as well as the identification of possible sources of interference from spurious signals. Furthermore, a mapping of the field strengths is presented and the means of determining the decay curve as a function of distance. This last type of measurement is done to estimate the effectiveness of grounding the machinery. The report ends with an estimate of the exposure of workers to electromagnetic fields and also some recommendations for reducing risk. (authors)

  16. Stochasticity and superadiabaticity in radiofrequency plasma heating

    International Nuclear Information System (INIS)

    Stix, T.H.

    1979-04-01

    In a plasma subject to radiofrequency fields, it is only the resonant particles - comprising just a minor portion of the total velocity distribution - which are strongly affected. Under near-fusion conditions, thermalization by Coulomb collisions is slow, and noncollisional stochasticity can play an important role in reshaping f(v). It is found that the common rf interactions, including Landau, cyclotron and transit-time damping, can be fitted in a unified manner by a simple two-step one-parameter (epsilon) mapping which can display collision-free stochastic or adiabatic (also called superadiabatic) behavior, depending on the choice of epsilon. The effect on the evolution of the space averaged f (x,v,t) is reasonably well described by a pseudo-stochastic diffusion function, D/sub PS/(v,epsilon) which is the quasilinear diffusion coefficient but with appropriate widening of the delta-function spikes. Coulomb collisions, leading to D/sub Coul/(v) which may be added and directly compared to D/sub PS/(v,epsilon), are introduced by Langevin terms in the mapping equations

  17. Radiofrequency generation by coherently moving fluxons

    Science.gov (United States)

    Dobrovolskiy, O. V.; Sachser, R.; Huth, M.; Shklovskij, V. A.; Vovk, R. V.; Bevz, V. M.; Tsindlekht, M. I.

    2018-04-01

    A lattice of Abrikosov vortices in type II superconductors is characterized by a periodic modulation of the magnetic induction perpendicular to the applied magnetic field. For a coherent vortex motion under the action of a transport current, the magnetic induction at a given point of the sample varies in time with a washboard frequency fWB = v/d, where v is the vortex velocity and d is the distance between the vortices in the direction of motion. Here, by using a spectrum analyzer connected to a 50 nm-wide Au nanowire meander near the surface of a superconducting Nb film, we detect an ac voltage induced by coherently moving fluxons. The voltage is peaked at the washboard frequency, fWB, and its subharmonics, fTOF = fWB/5, determined by the antenna width. By sweeping the dc current value, we reveal that fWB can be tuned from 100 MHz to 1.5 GHz, thereby demonstrating that patterned normal metal/superconductor nanostructures can be used as dc-tunable generators operating in the radiofrequency range.

  18. Spin gymnastics with selective radiofrequency pulses

    Energy Technology Data Exchange (ETDEWEB)

    Freeman, R.; Kupce, E. [Cambridge Univ. (United Kingdom)

    1994-12-31

    Although high resolution NMR spectra are normally excited with short intense radiofrequency pulses, there is an entire family of new experiments that can be performed with frequency-selective or ``soft`` pulses. Time-consuming two-dimensional spectroscopy may be reduced to a much shorter one-dimensional version with much finer digitization in the frequency domain. A large number of soft pulses can be combined to form a ``polychromatic pulse`` that has uniform excitation over the entire range of proton shifts except for a rejection notch at the water frequency. Polychromatic pulses can also be used to create antiphase magnetization in preparation for a coherence transfer or double-quantum experiment. An excitation profile can be designed in the form of a ``template`` that exactly matches the spectrum of a given chemical compound but has zero excitation elsewhere. This is achieved by using the information in the experimental free induction decay to construct a suitable array of soft pulses that has the required excitation pattern. In this manner, interpenetrating spectra can be separated into the spectra of the pure components, for example those of a and b glucose. Selective Hartmann-Hahn coherence transfer experiments employ similar soft pulse techniques. If several such transfers are concatenated, the method may be used as a test to see whether a group of protons is linked in an unbroken chain by scalar spin-spin interactions. (authors). 24 refs., 18 figs.

  19. Radiofrequency Heating Pathways for Gold Nanoparticles

    Science.gov (United States)

    Collins, C. B.; McCoy, R. S.; Ackerson, B. J.; Collins, G. J.

    2015-01-01

    This feature article reviews the thermal dissipation of nanoscopic gold under radiofrequency (RF) irradiation. It also presents previously unpublished data addressing obscure aspects of this phenomenon. While applications in biology motivated initial investigation of RF heating of gold nanoparticles, recent controversy concerning whether thermal effects can be attributed to nanoscopic gold highlight the need to understand the involved mechanism or mechanisms of heating. Both the nature of the particle and the nature of the RF field influence heating. Aspects of nanoparticle chemistry and physics, including the hydrodynamic diameter of the particle, the oxidation state and related magnetism of the core, and the chemical nature of the ligand shell may all strongly influence to what extent a nanoparticle heats in an RF field. Aspects of RF include: power, frequency and antenna designs that emphasize relative strength of magnetic or electric fields, and also influence the extent to which a gold nanoparticle heats in RF. These nanoparticle and RF properties are analysed in the context of three heating mechanisms proposed to explain gold nanoparticle heating in an RF field. This article also makes a critical analysis of the existing literature in the context of the nanoparticle preparations, RF structure, and suggested mechanisms in previously reported experiments. PMID:24962620

  20. Radiofrequency ablation for renal tumors. Our experience

    International Nuclear Information System (INIS)

    Hiraoka, Kenji; Kawauchi, Akihiro; Nakamura, Terukazu; Soh, Jintetsu; Mikami, Kazuya; Miki, Tsuneharu

    2009-01-01

    The objective of this study was to report our results of percutaneous radiofrequency ablation (RFA) for renal tumors and to assess predictors of therapeutic efficacy. Forty patients (median age 73 years) with renal tumors were treated with RFA under local or epidural anesthesia. All of them had high surgical risk or refused radical surgery. Tumors were punctured percutaneously using the Radionics Cool-tip RF System under computed tomography or ultrasonographic guidance. Median tumor diameter was 24 mm. After RFA, contrast-enhanced computed tomography or magnetic resonance imaging was performed within 1 month. Complete response (CR) was defined as no enhancement inside the tumor. Factors related to the outcome and to renal function were assessed. Median follow up was 16 months. CR was observed in 34 cases (85.0%). A significant difference in CR rate was observed between tumors ≤30 mm and those >30 mm. Outcomes tended to be better for tumors in the mid to lower kidney, and those away from the renal hilum. Recurrence was observed in one case (2.9%), but a CR was obtained again by additional RFA. Out of a total of 77 RFA procedures, complications occurred in only three cases (3.9%), and conservative treatment was possible in all cases. Serum creatinine levels 3 months after RFA did not differ from those before RFA. Percutaneous RFA is a safe and effective treatment for small renal tumors in patients with high surgical risk or who refuse radical surgery. (author)

  1. Radio-frequency plasma spraying of ceramics

    International Nuclear Information System (INIS)

    Okada, T.; Hamatani, H.; Yoshida, T.

    1989-01-01

    This study was aimed at developing a novel spraying process using a radio-frequency (rf) plasma. Experiments of Al 2 O 3 and ZrO 2 - 8 wt% Y 2 O 3 spraying showed that the initial powder size was the most important parameter for depositing dense coatings. The optimum powder sizes of Al 2 O 3 and ZrO 2 - 8 wt% Y 2 O 3 were considered to be around 100 and 80 μm, respectively. The use of such large-size powders compared with those used by conventional dc plasma spraying made it possible to deposit adherent ceramics coatings of 150 to 300 μm on as-rolled SS304 substrates. It was also shown that low particle velocity of about 10 m/s, which is peculiar to rf plasma spraying, was sufficient for particle deformation, though it imposed a severe limitation on the substrate position. These experimental results prove that rf plasma spraying is an effective process and a strong candidate to open new fields of spraying applications

  2. Radiofrequency facial rejuvenation: evidence-based effect.

    Science.gov (United States)

    el-Domyati, Moetaz; el-Ammawi, Tarek S; Medhat, Walid; Moawad, Osama; Brennan, Donna; Mahoney, My G; Uitto, Jouni

    2011-03-01

    Multiple therapies involving ablative and nonablative techniques have been developed for rejuvenation of photodamaged skin. Monopolar radiofrequency (RF) is emerging as a gentler, nonablative skin-tightening device that delivers uniform heat to the dermis at a controlled depth. We evaluated the clinical effects and objectively quantified the histologic changes of the nonablative RF device in the treatment of photoaging. Six individuals of Fitzpatrick skin type III to IV and Glogau class I to II wrinkles were subjected to 3 months of treatment (6 sessions at 2-week intervals). Standard photographs and skin biopsy specimens were obtained at baseline, and at 3 and 6 months after the start of treatment. We performed quantitative evaluation of total elastin, collagen types I and III, and newly synthesized collagen using computerized histometric and immunohistochemical techniques. Blinded photographs were independently scored for wrinkle improvement. RF produced noticeable clinical results, with high satisfaction and corresponding facial skin improvement. Compared with the baseline, there was a statistically significant increase in the mean of collagen types I and III, and newly synthesized collagen, while the mean of total elastin was significantly decreased, at the end of treatment and 3 months posttreatment. A limitation of this study is the small number of patients, yet the results show a significant improvement. Although the results may not be as impressive as those obtained by ablative treatments, RF is a promising treatment option for photoaging with fewer side effects and downtime. Copyright © 2010 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.

  3. Characterization of tracked radiofrequency ablation in phantom

    International Nuclear Information System (INIS)

    Chen, Chun-Cheng R.; Miga, Michael I.; Galloway, Robert L.

    2007-01-01

    In radiofrequency ablation (RFA), successful therapy requires accurate, image-guided placement of the ablation device in a location selected by a predictive treatment plan. Current planning methods rely on geometric models of ablations that are not sensitive to underlying physical processes in RFA. Implementing plans based on computational models of RFA with image-guided techniques, however, has not been well characterized. To study the use of computational models of RFA in planning needle placement, this work compared ablations performed with an optically tracked RFA device with corresponding models of the ablations. The calibration of the tracked device allowed the positions of distal features of the device, particularly the tips of the needle electrodes, to be determined to within 1.4±0.6 mm of uncertainty. Ablations were then performed using the tracked device in a phantom system based on an agarose-albumin mixture. Images of the sliced phantom obtained from the ablation experiments were then compared with the predictions of a bioheat transfer model of RFA, which used the positional data of the tracked device obtained during ablation. The model was demonstrated to predict 90% of imaged pixels classified as being ablated. The discrepancies between model predictions and observations were analyzed and attributed to needle tracking inaccuracy as well as to uncertainties in model parameters. The results suggest the feasibility of using finite element modeling to plan ablations with predictable outcomes when implemented using tracked RFA

  4. Radiation effects in optoelectronic devices

    International Nuclear Information System (INIS)

    Barnes, C.E.

    1977-03-01

    A summary is given of studies on radiation effects in light-emitting diodes, laser diodes, detectors, optical isolators and optical fibers. It is shown that the study of radiation damage in these devices can provide valuable information concerning the nature of the devices themselves, as well as methods of hardening these devices for applications in radiation environments

  5. Systematic Review of Radiofrequency Ablation and Pulsed Radiofrequency for Management of Cervicogenic Headaches.

    Science.gov (United States)

    Grandhi, Ravi K; Kaye, Alan David; Abd-Elsayed, Alaa

    2018-02-23

    Cervicogenic headache (CHA) is a secondary headache which has a source in the upper cervical spine. Many traditional analgesic choices lack good efficacy in managing the associated pain. As a result, in management of CHA, radiofrequency ablation (RFA) or pulse radiofrequency (PRF) has been tried with success. Our study investigated the use of RFA and PRF for the management of CHA. In the present investigation, a review of the literature was conducted using PubMed (1966 to February 2017). The quality assessment was determined using The Cochrane Risk of Bias. After initial search and consultation with experts, 34 articles were identified for initial review and 10 articles met inclusion for review. Criteria for inclusion were primarily based on identification of articles discussing cervicogenic headaches which were previously treatment resistant and occurred without any other pathology of the craniofacial region or inciting event such as trauma. This systematic review demonstrated that RFA and PRFA provide very limited benefit in the management of CHA. At present, there is no high-quality RCT and/or strong non-RCTs to support the use of these techniques, despite numerous case reports which have demonstrated benefit. This review is one of the first to provide a comprehensive overview of the use of RFA and PRF in the management of CHA.

  6. Symplicity multi-electrode radiofrequency renal denervation system feasibility study.

    Science.gov (United States)

    Whitbourn, Robert; Harding, Scott A; Walton, Antony

    2015-05-01

    The aim of this study was to test the safety and performance of the Symplicity™ multi-electrode radio-frequency renal denervation system which was designed to reduce procedure time during renal denervation. The multi-electrode radiofrequency renal denervation system feasibility study is a prospective, non-randomised, open label, feasibility study that enrolled 50 subjects with hypertension. The study utilises a new renal denervation catheter which contains an array of four electrodes mounted in a helical configuration at 90 degrees from each other to deliver radiofrequency energy simultaneously to all four renal artery quadrants for 60 seconds. The protocol specified one renal denervation treatment towards the distal end of each main renal artery with radiofrequency energy delivered for 60 seconds per treatment. Total treatment time for both renal arteries was two minutes. The 12-month change in office systolic blood pressure (SBP) and 24-hour SBP was -19.2±25.2 mmHg, prenal artery stenosis or hypertensive emergencies occurred. The Symplicity multi-electrode radiofrequency renal denervation system was associated with a significant reduction in SBP at 12 months and minimal complications whilst it also reduced procedure time. NCT01699529.

  7. Radiofrequency for the treatment of skin laxity: mith or truth*

    Science.gov (United States)

    de Araújo, Angélica Rodrigues; Soares, Viviane Pinheiro Campos; da Silva, Fernanda Souza; Moreira, Tatiane da Silva

    2015-01-01

    The nonablative radiofrequency is a procedure commonly used for the treatment of skin laxity from an increase in tissue temperature. The goal is to induce thermal damage to thus stimulate neocollagenesis in deep layers of the skin and subcutaneous tissue. However, many of these devices haven't been tested and their parameters are still not accepted by the scientific community. Because of this, it is necessary to review the literature regarding the physiological effects and parameters for application of radiofrequency and methodological quality and level of evidence of studies. A literature search was performed in MEDLINE, PEDro, SciELO, PubMed, LILACS and CAPES and experimental studies in humans, which used radiofrequency devices as treatment for facial or body laxity, were selected. The results showed that the main physiological effect is to stimulate collagen synthesis. There was no homogeneity between studies in relation to most of the parameters used and the methodological quality of studies and level of evidence for using radiofrequency are low. This fact complicates the determination of effective parameters for clinical use of this device in the treatment of skin laxity. The analyzed studies suggest that radiofrequency is effective, however the physiological mechanisms and the required parameters are not clear in the literature. PMID:26560216

  8. Treatment of acne vulgaris with fractional radiofrequency microneedling.

    Science.gov (United States)

    Kim, Sang Tae; Lee, Kang Hoon; Sim, Hyung Jun; Suh, Kee Suck; Jang, Min Soo

    2014-07-01

    Fractional radiofrequency microneedling is a novel radiofrequency technique that uses insulated microneedles to deliver energy to the deep dermis at the point of penetration without destruction of the epidermis. It has been used for the treatment of various dermatological conditions including wrinkles, atrophic scars and hypertrophic scars. There have been few studies evaluating the efficacy of fractional radiofrequency microneedling in the treatment of acne, and none measuring objective parameters like the number of inflammatory and non-inflammatory acne lesions or sebum excretion levels. The safety and efficacy of fractional radiofrequency microneedling in the treatment of acne vulgaris was investigated. In a prospective clinical trial, 25 patients with moderate to severe acne were treated with fractional radiofrequency microneedling. The procedure was carried out three times at 1-month intervals. Acne lesion count, subjective satisfaction score, sebum excretion level and adverse effects were assessed at baseline and at 4, 8 and 12 weeks after the first treatment as well as 4, 8 and 12 weeks after the last treatment. Number of acne lesions (inflammatory and non-inflammatory) decreased. Sebum excretion and subjective satisfaction were more favorable at every time point compared with the baseline values (P acne vulgaris. © 2014 Japanese Dermatological Association.

  9. Radiofrequency ablation of liver tumors (II): clinical application and outcomes.

    Science.gov (United States)

    Vanagas, Tomas; Gulbinas, Antanas; Pundzius, Juozas; Barauskas, Giedrius

    2010-01-01

    Radiofrequency ablation is one of the alternatives in the management of liver tumors, especially in patients who are not candidates for surgery. The aim of this article is to review applicability of radiofrequency ablation achieving complete tumor destruction, utility of imaging techniques for patients' follow-up, indications for local ablative procedures, procedure-associated morbidity and mortality, and long-term results in patients with different tumors. The success of local thermal ablation consists in creating adequate volumes of tissue destruction with adequate "clear margin," depending on improved delivery of radiofrequency energy and modulated tissue biophysiology. Different volumes of coagulation necrosis are achieved applying different types of electrodes, pulsing energy sources, utilizing sophisticated ablation schemes. Some additional methods are used to increase the overall deposition of energy through alterations in tissue electrical conductivity, to improve heat retention within the tissue, and to modulate tolerance of tumor tissue to hyperthermia. Contrast-enhanced computed tomography, magnetic resonance imaging, ultrasound or positron emission tomography are applied to control the effectiveness of radiofrequency ablation. The long-term results of radiofrequency ablation are controversial.

  10. Visualizing radiofrequency-skin interaction using multiphoton microscopy in vivo.

    Science.gov (United States)

    Tsai, Tsung-Hua; Lin, Sung-Jan; Lee, Woan-Ruoh; Wang, Chun-Chin; Hsu, Chih-Ting; Chu, Thomas; Dong, Chen-Yuan

    2012-02-01

    Redundant skin laxity is a major feature of aging. Recently, radiofrequency has been introduced for nonablative tissue tightening by volumetric heating of the deep dermis. Despite the wide range of application based on this therapy, the effect of this technique on tissue and the subsequent tissue remodeling have not been investigated in detail. Our objective is to evaluate the potential of non-linear optics, including multiphoton autofluorescence and second harmonic generation (SHG) microscopy, as a non-invasive imaging modality for the real-time study of radiofrequency-tissue interaction. Electro-optical synergy device (ELOS) was used as the radiofrequency source in this study. The back skin of nude mouse was irradiated with radiofrequency at different passes. We evaluated the effect on skin immediately and 1 month after treatment with multiphoton microscopy. Corresponding histology was performed for comparison. We found that SHG is negatively correlated to radiofrequency passes, which means that collagen structural disruption happens immediately after thermal damage. After 1 month of collagen remodeling, SHG signals increased above baseline, indicating that collagen regeneration has occurred. Our findings may explain mechanism of nonablative skin tightening and were supported by histological examinations. Our work showed that monitoring the dermal heating status of RF and following up the detailed process of tissue reaction can be imaged and quantified with multiphoton microscopy non-invasively in vivo. Copyright © 2011. Published by Elsevier Ireland Ltd.

  11. The precautionary principle in the context of mobile phone and base station radiofrequency exposures.

    Science.gov (United States)

    Dolan, Mike; Rowley, Jack

    2009-09-01

    No health hazard has been established from exposure to radiofrequency fields up to the levels recommended by the International Commission on Non-Ionizing Radiation Protection. However, in response to public concern and the perceived level of scientific uncertainty, there are continuing calls for the application of the precautionary principle to radiofrequency exposures from mobile phones and base stations. We examined the international evolution of calls for precautionary measures in relation to mobile phones and base stations, with particular focus on Australia and the United Kingdom. The precautionary principle is difficult to define, and there is no widespread agreement as to how it should be implemented. However, there is a strong argument that precautionary measures should not be implemented in the absence of reliable scientific data and logical reasoning pointing to a possible health hazard. There is also experimental evidence that precautionary advice may increase public concern. We argue that conservative exposure standards, technical features that minimize unnecessary exposures, ongoing research, regular review of standards, and availability of consumer information make mobile communications inherently precautionary. Commonsense measures can be adopted by individuals, governments, and industry to address public concern while ensuring that mobile networks are developed for the benefit of society.

  12. Flexible organic light-emitting device based on magnetron sputtered indium-tin-oxide on plastic substrate

    International Nuclear Information System (INIS)

    Wong, F.L.; Fung, M.K.; Tong, S.W.; Lee, C.S.; Lee, S.T.

    2004-01-01

    A radio-frequency sputtering deposition method was applied to prepare indium tin oxide (ITO) on a plastic substrate, polyethylene terephthalate (PET). The correlation of deposition conditions and ITO film properties was systematically investigated and characterized. The optimal ITO films had a transmittance of over 90% in the visible range (400-700 nm) and a resistivity of 5.0x10 -4 Ω-cm. Sequentially α-napthylphenylbiphenyl diamine, tris-(8-hydroxyquinoline) aluminium, and magnesium-silver were thermally deposited on the ITO-coated PET substrate to fabricate flexible organic light-emitting diodes (FOLEDs). The fabricated devices had a maximum current efficiency of ∼4.1 cd/A and a luminance of nearly 4100 cd/m 2 at 100 mA/cm 2 . These values showed that the FOLEDs had comparable performance characteristics with the conventional organic light-emitting diodes made on ITO-coated glasses with the same device configuration

  13. High performance multilayered nano-crystalline silicon/silicon-oxide light-emitting diodes on glass substrates

    Energy Technology Data Exchange (ETDEWEB)

    Darbari, S; Shahmohammadi, M; Mortazavi, M; Mohajerzadeh, S [Thin Film and Nano-Electronic Laboratory, School of ECE, University of Tehran, Tehran (Iran, Islamic Republic of); Abdi, Y [Nano-Physics Research Laboratory, Department of Physics, University of Tehran, Tehran (Iran, Islamic Republic of); Robertson, M; Morrison, T, E-mail: mohajer@ut.ac.ir [Department of Physics, Acadia University, Wolfville, NS (Canada)

    2011-09-16

    A low-temperature hydrogenation-assisted sequential deposition and crystallization technique is reported for the preparation of nano-scale silicon quantum dots suitable for light-emitting applications. Radio-frequency plasma-enhanced deposition was used to realize multiple layers of nano-crystalline silicon while reactive ion etching was employed to create nano-scale features. The physical characteristics of the films prepared using different plasma conditions were investigated using scanning electron microscopy, transmission electron microscopy, room temperature photoluminescence and infrared spectroscopy. The formation of multilayered structures improved the photon-emission properties as observed by photoluminescence and a thin layer of silicon oxy-nitride was then used for electrical isolation between adjacent silicon layers. The preparation of light-emitting diodes directly on glass substrates has been demonstrated and the electroluminescence spectrum has been measured.

  14. Interaction of measles virus vectors with Auger electron emitting radioisotopes

    International Nuclear Information System (INIS)

    Dingli, David; Peng, K.-W.; Harvey, Mary E.; Vongpunsawad, Sompong; Bergert, Elizabeth R.; Kyle, Robert A.; Cattaneo, Roberto; Morris, John C.; Russell, Stephen J.

    2005-01-01

    A recombinant measles virus (MV) expressing the sodium iodide symporter (NIS) is being considered for therapy of advanced multiple myeloma. Auger electrons selectively damage cells in which the isotope decays. We hypothesized that the Auger electron emitting isotope 125 I can be used to control viral proliferation. MV was engineered to express both carcinoembryonic antigen and NIS (MV-NICE). Cells were infected with MV-NICE and exposed to 125 I with appropriate controls. MV-NICE replication in vitro is inhibited by the selective uptake of 125 I by cells expressing NIS. Auger electron damage is partly mediated by free radicals and abrogated by glutathione. In myeloma xenografts, control of MV-NICE with 125 I was not possible under the conditions of the experiment. MV-NICE does not replicate faster in the presence of radiation. Auger electron emitting isotopes effectively stop propagation of MV vectors expressing NIS in vitro. Additional work is necessary to translate these observations in vivo

  15. Longitudinally mounted light emitting plasma in a dielectric resonator

    Energy Technology Data Exchange (ETDEWEB)

    Gilliard, Richard; DeVincentis, Marc; Hafidi, Abdeslam; O' Hare, Daniel; Hollingsworth, Gregg [LUXIM Corporation, 1171 Borregas Avenue, Sunnyvale, CA 94089 (United States)

    2011-06-08

    Methods for coupling power from a dielectric resonator to a light-emitting plasma have been previously described (Gilliard et al IEEE Trans. Plasma Sci. at press). Inevitably, regardless of the efficiency of power transfer, much of the emitted light is absorbed in the resonator itself which physically surrounds much if not all of the radiating material. An investigation into a method is presented here for efficiently coupling power to a longitudinally mounted plasma vessel which is mounted on the surface of the dielectric material of the resonator, thereby eliminating significant absorption of light within the resonator structure. The topology of the resonator and its physical properties as well as those of the metal halide plasma are presented. Results of basic models of the field configuration and plasma are shown as well as a configuration suitable as a practical light source.

  16. 21 CFR 870.2910 - Radiofrequency physiological signal transmitter and receiver.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiofrequency physiological signal transmitter... Devices § 870.2910 Radiofrequency physiological signal transmitter and receiver. (a) Identification. A radiofrequency physiological signal transmitter and receiver is a device used to condition a physiological signal...

  17. Cooling analysis of a light emitting diode automotive fog lamp

    Directory of Open Access Journals (Sweden)

    Zadravec Matej

    2017-01-01

    Full Text Available Efficiency of cooling fins inside of a light emitting diode fog lamp is studied using computational fluid dynamics. Diffusion in heat sink, natural convection and radiation are the main principles of the simulated heat transfer. The Navier-Stokes equations were solved by the computational fluid dynamics code, including Monte Carlo radiation model and no additional turbulence model was needed. The numerical simulation is tested using the existing lamp geometry and temperature measurements. The agreement is excellent inside of few degrees at all measured points. The main objective of the article is to determine the cooling effect of various heat sink parts. Based on performed simulations, some heat sink parts are found to be very ineffective. The geometry and heat sink modifications are proposed. While radiation influence is significant, compressible effects are found to be minor.

  18. Ultraviolet light-emitting diodes in water disinfection.

    Science.gov (United States)

    Vilhunen, Sari; Särkkä, Heikki; Sillanpää, Mika

    2009-06-01

    The novel system of ultraviolet light-emitting diodes (UV LEDs) was studied in water disinfection. Conventional UV lamps, like mercury vapor lamp, consume much energy and are considered to be problem waste after use. UV LEDs are energy efficient and free of toxicants. This study showed the suitability of LEDs in disinfection and provided information of the effect of two emitted wavelengths and different test mediums to Escherichia coli destruction. Common laboratory strain of E. coli (K12) was used and the effects of two emitted wavelengths (269 and 276 nm) were investigated with two photolytic batch reactors both including ten LEDs. The effects of test medium were examined with ultrapure water, nutrient and water, and nutrient and water with humic acids. Efficiency of reactors was almost the same even though the one emitting higher wavelength had doubled optical power compared to the other. Therefore, the effect of wavelength was evident and the radiation emitted at 269 nm was more powerful. Also, the impact of background was studied and noticed to have only slight deteriorating effect. In the 5-min experiment, the bacterial reduction of three to four log colony-forming units (CFU) per cubic centimeter was achieved, in all cases. When turbidity of the test medium was greater, part of the UV radiation was spent on the absorption and reactions with extra substances on liquid. Humic acids can also coat the bacteria reducing the sensitivity of the cells to UV light. The lower wavelength was distinctly more efficient when the optical power is considered, even though the difference of wavelengths was small. The reason presumably is the greater absorption of DNA causing more efficient bacterial breakage. UV LEDs were efficient in E. coli destruction, even if LEDs were considered to have rather low optical power. The effect of wavelengths was noticeable but the test medium did not have much impact. This study found UV LEDs to be an optimal method for bacterial

  19. Radiofrequency ablation of osteoid osteomas: five years experience.

    Science.gov (United States)

    Papathanassiou, Zafiria G; Petsas, Theodore; Papachristou, Dionysios; Megas, Panagiotis

    2011-12-01

    The purpose of this study is to retrospectively evaluate the efficacy of radiofrequency ablation as a curative treatment method for benign bone tumours. Twenty-nine osteoid osteomas were treated with radiofrequency ablation. Primary success rate was 89.6% and total secondary success rate was 93.1%. Mean clinical follow-up period was 26.7 months (range: 6-63 months). Statistical analysis of 25 cases of osteoid osteomas with CT follow-up revealed that post-treatment re-ossification does not correlate with clinical outcome (p = 0.14) but is strongly correlated with long-term (> or = 12 months) CT follow-up (p = 0.014). Percutaneous radiofrequency ablation was found to be an effective and safe treatment for osteoid osteomas. CT findings cannot solely differentiate between treatment successes and failures.

  20. Influence of radiofrequency surgery on architecture of the palatine tonsils.

    Science.gov (United States)

    Plzak, Jan; Macokova, Pavla; Zabrodsky, Michal; Kastner, Jan; Lastuvka, Petr; Astl, Jaromir

    2014-01-01

    Radiofrequency surgery is a widely used modern technique for submucosal volume reduction of the tonsils. So far there is very limited information on morphologic changes in the human tonsils after radiofrequency surgery. We performed histopathological study of tonsillectomy specimens after previous bipolar radiofrequency induced thermotherapy (RFITT). A total of 83 patients underwent bipolar RFITT for hypertrophy of palatine tonsils. Tonsil volume reduction was measured by 3D ultrasonography. Five patients subsequently underwent tonsillectomy. Profound histopathological examination was performed to determine the effect of RFITT on tonsillar architecture. All tonsillectomy specimens showed the intact epithelium, intact germinal centers, normal vascularization, and no evidence of increased fibrosis. No microscopic morphological changes in tonsillectomy specimens after bipolar RFITT were observed. RFITT is an effective submucosal volume reduction procedure for treatment of hypertrophic palatine tonsils with no destructive effect on microscopic tonsillar architecture and hence most probably no functional adverse effect.