WorldWideScience

Sample records for radioactifs par interrogation

  1. Study and development of a method allowing the identification of actinides inside nuclear waste packages, by active neutron or photon interrogation and delayed gamma-ray spectrometry; Etude et developpement d'une technique de dosage des actinides dans les colis de dechets radioactifs par interrogation photonique ou neutronique active et spectrometrie des gamma retardes

    Energy Technology Data Exchange (ETDEWEB)

    Carrel, F

    2007-10-15

    An accurate estimation of the alpha-activity of a nuclear waste package is necessary to select the best mode of storage. The main purpose of this work is to develop a non-destructive active method, based on the fission process and allowing the identification of actinides ({sup 235}U, {sup 238}U, {sup 239}Pu). These three elements are the main alpha emitters contained inside a package. Our technique is based on the detection of delayed gammas emitted by fission products. These latter are created by irradiation with the help of a neutron or photon beam. Performances of this method have been investigated after an Active Photon or Neutron Interrogation (INA or IPA). Three main objectives were fixed in the framework of this thesis. First, we measured many yields of photofission products to compensate the lack of data in the literature. Then, we studied experimental performances of this method to identify a given actinide ({sup 239}Pu in fission, {sup 235}U in photofission) present in an irradiated mixture. Finally, we assessed the application of this technique on different mock-up packages for both types of interrogation (118 l mock-up package containing EVA in fission, 220 l mock-up package with a wall of concrete in photofission). (author)

  2. Control of radioactive wastes and coupling of neutron/gamma measurements: use of radiative capture for the correction of matrix effects that penalize the fissile mass measurement by active neutron interrogation; Controle des dechets radioactifs et couplage de mesures neutron/gamma: exploitation de la capture radiative pour corriger les effets de matrice penalisant la mesure de la masse fissile par interrogation neutronique active

    Energy Technology Data Exchange (ETDEWEB)

    Loche, F

    2006-10-15

    In the framework of radioactive waste drums control, difficulties arise in the nondestructive measurement of fissile mass ({sup 235}U, {sup 239}Pu..) by Active Neutron Interrogation (ANI), when dealing with matrices containing materials (Cl, H...) influencing the neutron flux. The idea is to use the neutron capture reaction (n,{gamma}) to determine the matrix composition to adjust the ANI calibration coefficient value. This study, dealing with 118 litres, homogeneous drums of density less than 0,4 and composed of chlorinated and/or hydrogenated materials, leads to build abacus linking the {gamma} ray peak areas to the ANI calibration coefficient. Validation assays of these abacus show a very good agreement between the corrected and true fissile masses for hydrogenated matrices (max. relative standard deviation: 23 %) and quite good for chlorinated and hydrogenated matrices (58 %). The developed correction method improves the measured values. It may be extended to 0,45 density, heterogeneous drums. (author)

  3. The conditioning of radioactive waste by bitumen; Conditionnement des dechets radioactifs par le bitume

    Energy Technology Data Exchange (ETDEWEB)

    Rodier, J; Scheidhauer, J; Malabre, M [Commissariat a l' Energie Atomique, Chusclan (France). Centre de Production de Plutonium de Marcoule

    1961-07-01

    The separation of radioactive sludge and waste by bitumen is studied. Results are given concerning various trials carried out on the lixiviation of the final product by water as a function of the pH, of the time, and of the composition. The conditions for carrying out this process of coating the waste are controlled from a radioactive point of view. (author) [French] L'isolement de boues radioactives et de dechets par le bitume est etudie. Les resultats de divers essais portant sur la lixiviation par l'eau du produit fini en fonction du pH, du temps et de la composition sont exposes. Les conditions de realisation de l'enrobage sont controlees au point de vue du risque radioactif. (auteur)

  4. Experimental study of contamination by inhalation of radioactive iodine aerosols. Biological balance; Etude experimentale de la contamination par inhalation d'aerosols d'iode radioactif bilan biologique

    Energy Technology Data Exchange (ETDEWEB)

    Marble, G [Commissariat a l' Energie Atomique, 92 - Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1968-07-01

    Several articles have been published concerning research into contamination produced by inhalation of radioactive iodine aerosols in monkeys. Results dealing with the biological balance of this contamination are presented and discussed in this report. (author) [French] L'etude experimentale de la contamination par inhalation d'aerosols d'iode radioactif effectuee chez le singe a fait l'objet de plusieurs publications. Les resultats concernant le bilan biologique de cette contamination sont presentes et discutes dans ce rapport. (auteur)

  5. Elimination of slightly radioactive liquid effluent by dilution. Its consequences (1960); Elimination par dilution d'effluents liquides faiblement radioactifs. Leurs consequences (1960)

    Energy Technology Data Exchange (ETDEWEB)

    Bovard, P; Candillon, C [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    Nuclear centres often have to solve problems raised by the elimination of large volumes of slightly radioactive liquid effluent. As things stand at present, the method usually adopted consists in expelling this effluent into the main water system in order to dilute it to a maximum, and thus to lower its radioactive isotope concentration to below the norms imposed by the Public Health Service. This technique requires systematic checking of the water system and its dependences, and demands a thorough knowledge of adsorption and fixation processes. (author) [French] Les centres nucleaires ont frequemment a resoudre des problemes poses par l'elimination de volumes importants d'effluents liquides faiblement radioactifs. Dans l'etat actuel des choses, la solution la plus utilisee consiste a rejeter ces effluents dans le reseau hydrographique de maniere a les diluer au maximum et abaisser ainsi leurs teneurs en isotopes radioactifs au-dessous des normes imposees par la Sante Publique. Cette technique necessite un controle systematique du reseau et de ses dependances et demande une connaissance approfondie des processus d'adsorption et de fixation. (auteur)

  6. Beach sediments drift study by means of radioactive tracers; L'etude du transport littoral par la methode des traceurs radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    Hours, R [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires; Jaffry, P [Electricite de France (EDF), 78 - Chatou (France). Lab. National d' Hydraulique

    1959-07-01

    The present state of the sediments drift studies by means of radioactive tracers is exposed. Various processes of labelling, immersion and detection, used in France and other countries, are reviewed. A more extended analysis of some aspects of the problem by the same authors can be found in 'La Houille Blanche', number 3, may-june 1959 (Rapport C.E.A. number 1269). (author) [French] L'etude du transport littoral des sediments et galets par la methode des traceurs radioactifs est en plein developpement. Le present rapport precise l'etat actuel de la question. Les techniques de marquage, d'immersion et de detection utilisees en France et a l'etranger sont decrites; une analyse plus detaillee de certains aspects de la question est presentee par les memes auteurs dans 'La Houille Blanche', numero 3, mai-juin 1959 (Rapport C.E.A. numero 1269). (auteur)

  7. Health problems raised by the elimination of radioactive wastes and nuclear accidents; Problemes sanitaires poses par l'elimination des dechets radioactifs et par les accidents nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Jammet, H; Mechali, D; Dousset, M [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1964-07-01

    residus radioactifs produits par les installations nucleaires. L'evaluation du risque encouru par les populations et la fixation des limites admissibles pour les rejets ne peuvent resulter que d'une connaissance exacte du cheminement des radioelements rejetes, depuis leur source d'emission jusqu'a l'homme. L'incorporation des radioelements dans les chaines alimentaires constitue le premier risque a prendre en consideration. Les facteurs de passage doivent etre envisages, dans toutes les etapes de cette transmission, qu'elles interessent les milieux physiques ou les milieux proprement biologiques, du fait de leur continuite et de leur interdependance. Enfin, les donnees de caractere socio-economique et dietetique doivent etre recueillies pour conduire a une evaluation des risques et des niveaux admissibles reposant non sur des donnees theoriques mais sur des bases concretes et experimentales. Le risque d'accidents nucleaires dans l'industrie atomique, bien que de probabilite tres reduite, doit etre pris en consideration du fait de la gravite de leurs consequences. Les problemes sanitaires se posent d'une part dans le domaine de l'hygiene professionnelle, d'autre part dans celui de l'hygiene publique. Le premier domaine implique un risque double: d'irradiation et de contamination. Le domaine public n'est soumis essentiellement qu'au risque de contamination par les substances radioactives liberees accidentellement dans le milieu. Les etudes sanitaires a mener dans ce domaine comprennent, de ce fait, les recherches sur la therapeutique des irradiations ou des contaminations mais aussi celles relatives au transfert des radioelements depuis l'installation accidentee jusqu'a l'homme, principalement a travers les chaines alimentaires, dans leurs composantes physiques comme dans leurs composantes biologiques. De telles etudes sont a la base des decisions d'ordre sanitaire qu'il conviendrait de prendre dans le cas d'un accident. (auteurs)

  8. Health problems raised by the elimination of radioactive wastes and nuclear accidents; Problemes sanitaires poses par l'elimination des dechets radioactifs et par les accidents nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Jammet, H.; Mechali, D.; Dousset, M. [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1964-07-01

    residus radioactifs produits par les installations nucleaires. L'evaluation du risque encouru par les populations et la fixation des limites admissibles pour les rejets ne peuvent resulter que d'une connaissance exacte du cheminement des radioelements rejetes, depuis leur source d'emission jusqu'a l'homme. L'incorporation des radioelements dans les chaines alimentaires constitue le premier risque a prendre en consideration. Les facteurs de passage doivent etre envisages, dans toutes les etapes de cette transmission, qu'elles interessent les milieux physiques ou les milieux proprement biologiques, du fait de leur continuite et de leur interdependance. Enfin, les donnees de caractere socio-economique et dietetique doivent etre recueillies pour conduire a une evaluation des risques et des niveaux admissibles reposant non sur des donnees theoriques mais sur des bases concretes et experimentales. Le risque d'accidents nucleaires dans l'industrie atomique, bien que de probabilite tres reduite, doit etre pris en consideration du fait de la gravite de leurs consequences. Les problemes sanitaires se posent d'une part dans le domaine de l'hygiene professionnelle, d'autre part dans celui de l'hygiene publique. Le premier domaine implique un risque double: d'irradiation et de contamination. Le domaine public n'est soumis essentiellement qu'au risque de contamination par les substances radioactives liberees accidentellement dans le milieu. Les etudes sanitaires a mener dans ce domaine comprennent, de ce fait, les recherches sur la therapeutique des irradiations ou des contaminations mais aussi celles relatives au transfert des radioelements depuis l'installation accidentee jusqu'a l'homme, principalement a travers les chaines alimentaires, dans leurs composantes physiques comme dans leurs composantes biologiques. De telles etudes sont a la base des decisions d'ordre sanitaire qu

  9. Experimental study of contamination by inhalation of radioactive iodine aerosols. Biological balance; Etude experimentale de la contamination par inhalation d'aerosols d'iode radioactif bilan biologique

    Energy Technology Data Exchange (ETDEWEB)

    Marble, G. [Commissariat a l' Energie Atomique, 92 - Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1968-07-01

    Several articles have been published concerning research into contamination produced by inhalation of radioactive iodine aerosols in monkeys. Results dealing with the biological balance of this contamination are presented and discussed in this report. (author) [French] L'etude experimentale de la contamination par inhalation d'aerosols d'iode radioactif effectuee chez le singe a fait l'objet de plusieurs publications. Les resultats concernant le bilan biologique de cette contamination sont presentes et discutes dans ce rapport. (auteur)

  10. Kinetic ion exchange studies in ultramarines by the radioactive tracer method; Etudes cinetiques d'echanges d'ions dans les outremers par la technique des traceurs radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    May, S; Goenvec, H; Pinte, G [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    The possibility of ion exchanges in various ultramarines has been studied in the aqueous phase. The kinetics of the exchange reactions is followed by studying the behaviour of a radioactive ion, either in the solution of the exchanging salt or in the ultramarine itself. The sodium in the make-up of the ultramarine, is found to exchange with various ions in solution. The reaction speeds appear to be governed by a diffusion process inside the grains of ultramarine. The diffusion coefficients and the activation energies are determined for the exchanges studied. Several exchange studies were carried out in an organic medium. The kinetics of ion exchange is also investigated in ultramarines from which most of the constituent sulphur has been eliminated. The results obtained in these ultramarines are compared with the exchange kinetics of the same ions in ordinary ultramarine. (author) [French] Nous avons etudie la possibilite d'echanges ioniques dans differents outremers, en phase aqueuse. L'etude cinetique des reactions d'echanges est suivie en etudiant le comportement d'ion radioactif, soit dans la solution du sel echangeant, soit dans l'outremer lui-meme. C'est le sodium de constitution de l'outremer qui s'echange avec differents ions en solution. Les vitesses de reactions semblent etre controlees par un processus de diffusion a l'interieur des grains d'outremer. Les coefficients de diffusion et les energies d'activation sont determines pour les echanges etudies. Quelques etudes sont realisees en milieu organique ou quelques echanges ont ete etudies. La cinetique d'echange d'ions est egalement etudie dans des outremers dans lesquels la majorite du soufre de constitution a ete eliminee. On compare les resultats obtenus dans ces outremers avec les cinetiques d'echanges des memes ions dans l'outremer ordinaire. (auteur)

  11. Recovery of sludge from the treatment of liquid radioactive effluents by co-precipitation with calcium carbonate: laboratory study; Recuperation des boues de traitement des effluents radioactifs liquides par coprecipitation avec le carbonate de calcium: etude de laboratoire

    Energy Technology Data Exchange (ETDEWEB)

    Patti, F.; Gailledreau, C.; Cohen, P.

    1961-02-24

    As during the treatment by co-precipitation with calcium carbonate of liquid radioactive residues, a partial decontamination can be obtained by simply agitating an already formed radioactive sludge with the effluent to be processed, the authors study whether it would be possible to first perform a co-precipitation with a lower dose of calcium carbonate and then to complete decontamination by agitating with an adequate quantity of sludge stored during preceding operations. The authors report the study of the influence of reactant quantity on the chemical treatment efficiency, of the evolution of the activity of a radioactive residual solution in contact with a precipitate, of the cleaner element, of a precipitate reuse, of the technological and economic aspects, and of another possibility of reduction of the precipitate volume [French] Dans le traitement par coprecipitation avec le carbonate de calcium des residus radioactifs liquides, une decontamination partielle peut etre obtenue en agitant simplement une boue radioactive deja formee avec l'effluent a traiter. En consequence, il pourrait etre possible d'effectuer d'abord une coprecipitation avec une dose plus faible de carbonate de calcium et de completer ensuite la decontamination en agitant le liquide avec une quantite convenable de boue stockee a partir d'operations precedentes. (auteurs)

  12. Fissile materials in solution concentration measured by active neutron interrogation; Mesure de concentration en matiere fissile dans les liquides par interrogation neutronique active

    Energy Technology Data Exchange (ETDEWEB)

    Romeyer Dherbey, J.; Passard, Ch.; Cloue, J.; Bignan, G.

    1993-12-31

    The use of the active neutron interrogation to measure the concentration of plutonium contained in flow solutions is particularly interesting for fuel reprocessing plants. Indeed, this method gives a signal which is in a direct relation with the fissile materials concentration. Moreover, it is less sensitive to the gamma dose rate than the other nondestructive methods. Two measure methods have been evolved in CEA. Their principles are given into details in this work. The first one consists to detect fission delayed neutrons induced by a {sup 252} Cf source. In the second one fission prompt neutrons induced by a neutron generator of 14 MeV are detected. (O.M.). 6 refs.

  13. Quantitative analysis of strontium 90 in the radioactive wastes by means of thenoyltrifluoroacetone; Dosage du strontium 90 dans les effluents radioactifs par le thenoyltrifluoroacetone

    Energy Technology Data Exchange (ETDEWEB)

    Testemale, G; Leredde, J L [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1970-07-01

    A simple method of analysing the quantity of {sup 90}Sr has been perfected. It consists in a double extraction of it by means of thenoyltrifluoroacetone and tributylphosphate in tetrachloride of carbon followed by eliminating yttrium 90 by means of thenoyltrifluoroacetone in the benzene. Numberings on aliquot parts of wastes make the determination of that element possible. The yield is about 97 per cent. (authors) [French] Une technique simple du dosage du {sup 90}Sr a ete mise au point. Elle consiste en une double extraction par le thenoyltrifluoroacetone et le tributylphosphate dans le tetrachlorure de carbone, suivie de l'elimination de l'yttrium 90 par le thenoyltrifluoroacetone dans le benzene, Des comptages sur des parties aliquotes d'effluents permettent la dermination de cet element. Rendement environ 97 pour cent. (auteurs)

  14. Dosage of cesium 137 in radioactive wastes by the application of sodium tetraphenylborate; Dosage du cesium 137 dans les effluents radioactifs par le tetraphenylborate de sodium

    Energy Technology Data Exchange (ETDEWEB)

    Testemale, G; Girault, J [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1967-07-01

    A simple technique of the dosage of {sup 137}Cs has been developed. The technique consists in the formation of cesium tetraphenyl borate, followed by a double extraction with isoamyl acetate, and washing of the organic phase. The counting of known parts of the cesium solution assaying of its purity by {gamma} spectrometry enable the determination of the {sup 137}Cs. The yield is about 98 per cent. (authors) [French] Une technique simple du dosage du {sup 137}Cs a ete mise au point. Elle consiste en une double extraction du tetraphenylborate de cesium forme par l'acetate d'isoamyle suivie d'un lavage de la phase organique. Des comptages sur des parties aliquotes de la solution de cesium et un controle de purete par spectrometrie {gamma} permettent la determination de cet element. Rendement: environ 98 pour cent. (auteurs)

  15. Pharmacological study of radioactive-gold colloid transport by blood and by serous exudate; Contribution a l'etude pharmacologique du transport des colloides d'or radioactif par le sang et les exsudats sereux

    Energy Technology Data Exchange (ETDEWEB)

    Rousselet, J. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1966-06-01

    substances et particulierement dans le transport de l'or colloidal radioactif. Les fractions sanguines qui peuvent participer au transport de l'or colloidal sont les hematies, les leucocytes et elements histiocytaires, et le plasma. La repartition de la radioactivite dans ces elements est precisee en pratiquant des autoradiographies de coupes de culots de sang centrifuge et congele apres incubation avec de l'or colloidal. Cette etude montre l'importance du plasma dans le transport des particules radioactives. Nous avons alors recherche une fixation eventuelle de l'or colloidal 198 sur les diverses proteines seriques en appliquant certaines methodes de separation a savoir une filtration-exclusion sur colonne de gel de Sephadex G-200 et un fractionnement electrophoretique sur papier et sur acetate de cellulose gelatineux (cellogel). Nous avons etudie la liaison ''in vitro'' et ''in vivo'' des particules colloidales d'or 198 d'abord avec les proteines seriques de sujets sains puis avec les proteines des liquides d'epanchement d'origine pathologique, chez l'homme, ou du a une inflammation experimentale a la carragenine chez le rat. Les particules d'or colloidal 198 de 30 m{mu} (S-2) sont liees dans une certaine mesure aux {alpha}2 globulines sanguines ou ascitiques, celles de 5 m{mu} (S-6) sont liees aux {alpha}1 globulines de meme que les grains contenus dans l'or polydisperse. Cette liaison semble intervenir grace a la couche protectrice de macromolecules constituees par la gelatine. Seules les caracteristiques physicochimiques de grains colloidaux peuvent expliquer leur difference de localisation sur l'electrophoregramme. L'or sous forme ionique, par contre, est combine, aux seules albumines si la quantite de metal presente ne depasse pas une certaine limite. (auteur)

  16. Pharmacological study of radioactive-gold colloid transport by blood and by serous exudate; Contribution a l'etude pharmacologique du transport des colloides d'or radioactif par le sang et les exsudats sereux

    Energy Technology Data Exchange (ETDEWEB)

    Rousselet, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1966-06-01

    transport de l'or colloidal radioactif. Les fractions sanguines qui peuvent participer au transport de l'or colloidal sont les hematies, les leucocytes et elements histiocytaires, et le plasma. La repartition de la radioactivite dans ces elements est precisee en pratiquant des autoradiographies de coupes de culots de sang centrifuge et congele apres incubation avec de l'or colloidal. Cette etude montre l'importance du plasma dans le transport des particules radioactives. Nous avons alors recherche une fixation eventuelle de l'or colloidal 198 sur les diverses proteines seriques en appliquant certaines methodes de separation a savoir une filtration-exclusion sur colonne de gel de Sephadex G-200 et un fractionnement electrophoretique sur papier et sur acetate de cellulose gelatineux (cellogel). Nous avons etudie la liaison ''in vitro'' et ''in vivo'' des particules colloidales d'or 198 d'abord avec les proteines seriques de sujets sains puis avec les proteines des liquides d'epanchement d'origine pathologique, chez l'homme, ou du a une inflammation experimentale a la carragenine chez le rat. Les particules d'or colloidal 198 de 30 m{mu} (S-2) sont liees dans une certaine mesure aux {alpha}2 globulines sanguines ou ascitiques, celles de 5 m{mu} (S-6) sont liees aux {alpha}1 globulines de meme que les grains contenus dans l'or polydisperse. Cette liaison semble intervenir grace a la couche protectrice de macromolecules constituees par la gelatine. Seules les caracteristiques physicochimiques de grains colloidaux peuvent expliquer leur difference de localisation sur l'electrophoregramme. L'or sous forme ionique, par contre, est combine, aux seules albumines si la quantite de metal presente ne depasse pas une certaine limite. (auteur)

  17. Study of radioactive nuclides of very short half-life produced by fast neutrons; Etude de corps radioactifs a vie tres breve produits par neutrons rapides

    Energy Technology Data Exchange (ETDEWEB)

    Monnand, E [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1965-07-01

    Several radionuclides, already known, with half-lives ranging from 5 10{sup -5} to 1 second were observed by pulsed irradiations of C - Mg - Al - Y - In - Tl - Pb - Bi with 14.3 MeV neutrons. These radionuclides are: {sup 12}B (20 {+-} 0.4 ms) - {sup 24m}Na (20 {+-} 0.6 ms) - {sup 88m1}Y (0.332 {+-} 0.012 ms) - {sup 88m2}Y (14.6 {+-} 0.4 ms) - {sup 114m}In (43.5 {+-} 2 ms) - {sup 202m}Tl (0.570 {+-} 0.010 ms) - {sup 204m}Tl (0.063 {+-} 0.002 ms) - {sup 205m}Pb (5.5 {+-}0.3 ms) - {sup 206m}Pb (0.126 {+-} 0.006 ms) - {sup 207m}Pb (830 {+-} 30 ms) - {sup 208m}Bi (2.56 {+-} 0.1 ms). Their half-life, the {beta} and {gamma} rays energies and the production cross sections were measured. (author) [French] Plusieurs radionucleides deja connus, de periode comprise entre 5 10{sup -5} et 1 seconde ont ete observes par irradiation pulsee avec des neutrons de 14,3 MeV, des elements suivants: C - Mg - Al - Y - In - Tl - Pb - Bi. Ces radionucleides sont: {sup 12}B (20 {+-} 0.4 ms) - {sup 24m}Na (20 {+-} 0.6 ms) - {sup 88m1}Y (0.332 {+-} 0.012 ms) - {sup 88m2}Y (14.6 {+-} 0.4 ms) - {sup 114m}In (43.5 {+-} 2 ms) - {sup 202m}Tl (0.570 {+-} 0.010 ms) - {sup 204m}Tl (0.063 {+-} 0.002 ms) - {sup 205m}Pb (5.5 {+-}0.3 ms) - {sup 206m}Pb (0.126 {+-} 0.006 ms) - {sup 207m}Pb (830 {+-} 30 ms) - {sup 208m}Bi (2.56 {+-} 0.1 ms). Leur periode, l'energie des rayonnements {beta} et {gamma} emis, et la section efficace de production ont ete mesurees. (auteur)

  18. Processing radioactive effluents with ion-exchanging resins: study of result extrapolation; Traitement des effluents radioactifs par resines echangeuses d'ions: etude de l'extrapolation des resultats

    Energy Technology Data Exchange (ETDEWEB)

    Wormser, G.

    1960-05-03

    As a previous study showed the ion-exchanging resins could be used in Saclay for the treatment of radioactive effluents, the author reports a study which aimed at investigating to which extent thus obtained results could be extrapolated to the case of higher industrial columns. The author reports experiments which aimed at determining extrapolation modes which could be used for columns of organic resin used for radioactive effluent decontamination. He notably studied whether the Hiester and Vermeulen extrapolation law could be applied. Experiments are performed at constant percolation flow rate, at varying flow rate, and at constant flow rate [French] Plusieurs etudes ont ete faites dans le but d'examiner les possibilites d'emploi des resines echangeuses d'ions pour le traitement des effluents radioactifs. Dans un rapport preliminaire, nous avons montre dans quelles limites un tel procede pouvait etre utilise au Centre d'Etudes Nucleaires de Saclay. Les essais ont ete effectues sur des petites colonnes de resine au laboratoire; il est apparu ensuite necessaire de prevoir dans quelle mesure les resultats ainsi obtenus peuvent etre extrapoles a des colonnes industrielles, de plus grande hauteur. Les experiences dont les resultats sont exposes dans ce rapport, ont pour but de determiner les modes d'extrapolation qui pourraient etre employes pour des colonnes de resine organique utilisees pour la decontamination d'effluents radioactifs. Nous avons en particulier recherche si la loi d'extrapolation de Hiester et Vermeulen qui donne de bons resultats dans le cas de fixation d'ions radioactifs en presence d'un ion macrocomposant sur des terres, pouvait etre appliquee. Les experiences, en nombre limite, ont montre que la loi d'extrapolation de Hiester et Vermeulen pouvait s'appliquer dans le cas de l'effluent considere quand les debits de percolation sont tres faibles; quand ils sont plus forts, les volumes de liquide percoles, a fixation egale, sont proportionnels aux

  19. Disposal of Low-Activity Liquid Effluents by Dilution; Elimination par Dilution d'Effluents Liquides Faiblement Radioactifs; 0423 0414 0410 041b 0414 ; Eliminacion de Efluentes Liquidos de Baja Radiactividad por Dilucion

    Energy Technology Data Exchange (ETDEWEB)

    Bovard, P.; Candillon, C. [Service de Controle des Radiations et de Genie Radioactif, Commissariat a l' Energie Atomique, Saclay (France)

    1960-07-01

    obtenus Nous avons commence en 1957 une etude evolutive de l'incidence des installations nucleaires. Cette etude embrasse la determination des niveaux - de radioactivite naturelle - de contamination artificielle afin d'en degager la part revenant aux Centres Nucleaires. Des exemples sont cites faisant appel a des zones de reference. La plus grande partie de la radioactivite artificielle semble due aux retombees radioactives; ceci n'est pas surprenant si on examine les quantites d'isotopes radioactifs rejetees jusqu'a present en France. Un certain nombre d'essais de laboratoire ont ete effectues. Ils ont contribue a preciser certains mecanismes, ont accru notre connaissance de la pollution des sites et nous ont permis d'ameliorer nos methodes de prelevement. II. Essais de laboratoire Ils ont porte: 1. sur des 'phenomenes d'adsorption analogues a ceux produits dans les rivieres au cours de la dilution des effluents: fixation sur mineraux tres divises: mica, quartz. Des radioisotopes tels que {sup 90}Sr, {sup 137}Cs, {sup 90}Y semblent se comporter fort differemment: dans les conditions moyennes de rejet, le {sup 90}Sr serait le moins adsorbe. : 2. sur la contamination du sol et des vegetaux par l'emploi de colonnes et de cubes de sol en place. Ceci nous a conduit a standardiser nos prelevements, afin de faciliter les analyses ulterieures et de comparer utilement les resultats. III. Choix du site et modalites des rejets De ce faisceau de resultats et d'etudes encore incomplets, nous essayons de degager quelques principes quant au choix des sites. Le site une fois defini, l'experience acquise permet de tirer le meilleur parti des possibilites naturelles. (author) [Spanish] Con los resultados obtenidos en Francia vigilando la radiactividad en las proximidades de las instalaciones nucleares se pueden extraer determinadas conclusiones acerca de la eleccion de los procedimientos de evacuacion. I. Resultados obtenidos Los autores iniciaron en 1957 un estudio evolutivo de las

  20. Simultaneous photon and neutron interrogation using an electron accelerator in order to quantify actinides in encapsulated radioactive wastes; Double interrogation simultanee neutrons et photons utilisant un accelerateur d'electrons pour la caracterisation separee des actinides dans les dechets radioactifs enrobes

    Energy Technology Data Exchange (ETDEWEB)

    Jallu, F

    1999-09-24

    Measuring out alpha emitters, such as ({sup 234,235,236,238}U {sup 238,239,240,242,}2{sup 44P}u, {sup 237}Np {sup 241,243}Am...), in solid radioactive waste, allows us to quantify the alpha activity in a drum and then to classify it. The SIMPHONIE (SIMultaneous PHOton and Neutron Interrogation Experiment) method, developed in this Ph.D. work, combines both the Active Neutron Interrogation and the Induced Photofission Interrogation techniques simultaneously. Its purpose is to quantify in only one measurement, fissile ({sup 235}U, {sup 239,241}Pu...) and fertile ({sup 236,238}U, {sup 238,240}Pu...) elements separately. In the first chapter of this Ph.D. report, we present the principle of the Radioactive Waste Management in France. The second chapter deals with the physical properties of neutron fission and of photofission. These two nuclear reactions are the basis of the SIMPHONIE method. Moreover, one of our purposes was to develop the ELEPHANT (ELEctron PHoton And Neutron Transport) code in view to simulate the electron, photon and neutron transport, including the ({gamma}, n), ({gamma}, 2n) and ({gamma}, f) photonuclear reactions that are not taken into account in the MCNP4 (Monte Carlo N-Particle) code. The simulation codes developed and used in this work are detailed in the third chapter. Finally, the fourth chapter gives the experimental results of SIMPHONIE obtained by using the DGA/ETCA electron linear accelerators located at Arcueil, France. Fissile ({sup 235}U, {sup 239}Pu) and fertile ({sup 238}U) samples were studied. Furthermore, comparisons between experimental results and calculated data of photoneutron production in tungsten, copper, praseodymium and beryllium by using an electron LINear Accelerator (LINAC) are given. This allows us to evaluate the validity degree of the ELEPHANT code, and finally the feasibility of the SIMPHONIE method. (author)

  1. A contribution to the study of radioactive waste dilution in the Rhone involving tests with a rhodamine B tracer; Contribution a l'etude de la dilution des effluents radioactifs dans le Rhone par le rejet experimental de rhodamine B

    Energy Technology Data Exchange (ETDEWEB)

    Rodier, J.; Marichal, M. [Commissariat a l' energie atomique et aux energies alternatives - CEA, Centre de production de plutonium de Marcoule, Service de protection contre les radiations (France)

    1961-07-01

    The process whereby waste from the Marcoule plant mixes with the water in the Rhone was followed in tests with rhodamine as a chemical tracer. Satisfactory dispersion was noted less than 4 km downstream from the waste discharge duct outlet, and the degree of homogeneity was considered to be satisfactory at the bridge of Roquemaure, und perfect at Avignon. This investigation not only revealed a complete absence of any preferential flow paths containing high radioactive waste concentrations, but it also enabled the most representative points to be selected at which to take Rhone water samples during future radioactive waste discharges. Reprint of a paper published in 'La Houille Blanche' N. 5 - Aug 196, p. 636-641 [French] L'emploi de la rhodamine comme traceur chimique a permis de suivre l'evolution du melange des effluents du Centre de Marcoule aux eaux du Rhone. La dispersion est deja satisfaisante a moins de 4 km en aval de la conduite des rejets, et l'homogeneite peut etre consideree comme atteinte au pont de Roquemaure et parfaite a Avignon. Cette etude a montre que les veines preferentielles ou se concentrait l'ecoulement des effluents radioactifs n'existent pas. Elle a permis de preciser en outre les emplacements les plus representatifs des points d'echantillonnage des eaux du Rhone au cours des rejets. Reproduction d'un article publie dans 'La houille blanche' N. 5 - Aug 196, p. 636-641.

  2. New Research Required in Support of Radioactive Waste Disposal; Recherches Nouvelles Necessitees par le Probleme de l'Elimination des Dechets Radioactifs; 041d 0415 041e 0411 0425 041e 0414 ; Nuevas Investigaciones Necesarias para la Evacuacion de Desechos Radiactivos

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, Milner B. [Inter-American Tropical Tuna Commission, Scripps Institution of Oceanography, La Jolla, CA (United States)

    1960-07-01

    foraines typiques, sur les processus de diffusion et de sedimentation dans les eaux proches du rivage et sur le passage des elements radioactifs tout le long de la chaine alimentaire dans cette partie de la mer. Il faut entreprendre des recherches pour delimiter les zones de peche presentes et eventuelles et les zones ou la peche ne se fait pas, en procedant a des etudes fondamentales sur la productivite biologique ou en recourant a d'autres moyens. Des etudes sont egalement necessaires pour determiner les taux de transfert de matieres radioactives entre les diverses zones par amenee hori-zontale et par diffusion turbulente, les taux de dilution par diffusion, sedimentation et transport vertical, et les taux d'entrainement et de transfert par les organismes. Une recherche s'impose en ce qui concerne les moyens efficaces de controle des zones d'evacuation des dechets. Certains organismes sont capables de concentrer selectivement des elements determines ;1 cette capacite constitue une base economique eventuelle pour le controle des dechets radioactifs existant dans la mer a des concentrations extremement faibles. Des propositions precises de recherche ont ete recemment mises au point par plusieurs groupes d'oceanographes aux Etats-Unis. Ces propositions ont ete resumees en meme temps que les estimations de. depenses y afferentes. (author) [Spanish] Numerosos son los procesos fisicos, quimicos y biologicos que influyen en la forma en que las sustancias radiactivas se distribuyen y vuelven al hombre. Entre ellos figuran la conveccion vertical y horizontal; la difusion turbulenta; la precipitacion y sedimentacion; la captacion, concentracion y transporte de los materiales radiactivos por organismos, y su paso al hombre por ingestion de alimentos de origen marino. Hay que estudiar urgentemente las caracteristicas del flujo y reflujo de las aguas en puertos tipicos, estuarios y aguas costeras abiertas ; los procesos de difusion y sedimentacion en las aguas costeras, y el paso de

  3. The Permanent Disposal of Highly Radioactive Wastes by Incorporation into Glass; Elimination Permanente de Dechets Hautement Radioactifs par Incorporation dans le Verre; 041e 041a 041e 041d 0427 0414 ; La Evacuacion Permanente de Desechos de Elevada Radiactividad Incorporandolos en Vidrio

    Energy Technology Data Exchange (ETDEWEB)

    Watson, L. C.; Aikin, A. M.; Bancroft, A. I. [Atomic Energy of Canada Ltd. (Canada)

    1960-07-01

    verre contenant un melange de produits de fission ayant cinq ou six ans d'age et dont l'activite allait jusqu'a 50 curies par kilogramme. L'operation s'est faite en discontinu, par lots de quatre kilogrammes. On a constate que les produits de fission peuvent etre incorpores dans le verre commodement et sans danger. En etudiant les nombreux problemes que posent le stockage et l'elimination permanents du verre hautement radioactif, on est parvenu a la conclusion que ce verre devrait etre, soit enfoui dans le sol, soit entrepose dans des souterrains artificiels. Dans ces conditions, il est toujours possible, en cas de besoin, de' proceder a un nouveau controle de l'elimination. Lorsque l'enfouissement se fait directement dans le sol, les produits de fission peuvent surtout etre liberes dans le milieu ambiant par lixiviation du verre dans l'eau. On estime donc important de connaitre le rythme auquel les produits de fission se dispersent par ce mecanisme. Une documentation abondante sur la lixiviation par l'eau a ete recueillie en laboratoire. On a constate que le rythme de liberation depend de la composition du verre. Pour toutes les compositions mises a l'epreuve, les mesures montrent que le rythme de lixiviation des produits de fission incorpores dans le verre decroit avec le temps. Apres plusieurs mois d'immersion dans l'eau, le rythme auquel les substances radioactives se degageaient du verre de differentes compositions etait de 10{sup -4} pour cent par an environ, pour des hemispheres en verre pesant deux kilogrammes. Les donnees recueillies ont servi a evaluer les quantites de produits de fission qui s'echapperont du verre auquel auront ete incorporees les masses importantes de produits de fission qui s'accumuleront par suite du fonctionnement des reacteurs de puissance. (author) [Spanish] En Chalk River se ha continuado el estudio de un proceso para incorporar en vidrio para su evacuacion permanente los desechos de alto nivel radiactivo resultantes de los procesos de

  4. Use of a thin-film evaporator for bitumen coating of radioactive concentrates; Utilisation d'un evaporateur a couche mince pour l'enrobage par le bitume de concentrats radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    Lefillatre, G; Rodier, J; Hullo, R; Cudel, Y; Rodi, L [Commissariat a l' Energie Atomique, Chusclan (France). Centre de Production de Plutonium de Marcoule

    1969-07-01

    Following the development in the laboratory of a process for coating evaporation concentrates with bitumen, a technological study of this coating process has been undertaken. The report describes a pilot installation for the bitumen coating of concentrates, which uses a thin-film evaporator LUWA L 150. The first, inactive series of tests was designed to determine the maximum and optimum capacities of the evaporator by varying the amounts of bitumen and of concentrate, the rotor speed and the thermo-fluid temperature. Two rotors were tested, one of conventional type, the other a model especially designed for high viscosity products. The maximum capacity of evaporation of the apparatus is 72 kg/hr for a heating temperature of 221 deg. C. During normal operation, the evaporator can produce 50 kg/hr of coated product containing 55 to 60 per cent of bitumen (Mexphalte 40/50), the water content of the product remaining under 0.5 per cent. A second series of tests will shortly be carried out on this pilot installation using, in particular, bituminous emulsions containing mainly Mexphalte 40/50 and 80/100. (authors) [French] A la suite de la mise au point en laboratoire d'un procede d'enrobage par le bitume de concentrats d'evaporation, une etude technologique de cet enrobage a ete entreprise. Ce rapport decrit une installation pilote d'enrobage par le bitume de concentrats utilisant un evaporateur a couche mince LUWA L 150. La premiere serie d'essais en inactif a eu pour but de definir les capacites maximales et optimales de l'evaporateur en faisant varier les dosages en bitume et en concentrats, la vitesse du rotor et la temperature du thermo-fluide. Deux rotors ont ete testes, l'un de type classique, l'autre d'un modele special concu pour les produits de haute viscosite. La capacite d'evaporation maximale de l'appareil est de 72 kg/h d'eau pour une temperature de chauffage de 221 deg. C. En marche normale l'evaporateur peut debiter 50 kg/h d'enrobe compose de 55 a 60

  5. Correcting the effects of the matrix using capture gamma-ray spectrometry: Application to measurement by Active Neutron Interrogation; Correction des effets de matrice par spectrometrie des rayonnements gamma de capture: Application a la mesure par Interrogation Neutronique Active (I.N.A.)

    Energy Technology Data Exchange (ETDEWEB)

    Baudry, G.

    2003-11-15

    In the field of the measurement of low masses of fissile material ({sup 235}U, {sup 239}Pu, {sup 241}Pu) in radioactive waste drums, the Active Neutron Interrogation is a non-destructive method achieving good results. It does however remain reliant upon uncertainties related to the matrix effects on interrogation and fission neutrons. The aim of this thesis is to develop a correction method able to take into account these matrix effects by quantifying the amount of absorbent materials (chlorine and hydrogen) in a 118- liter homogeneous matrix. The main idea is to use the gamma-ray spectrometry of gamma emitted by neutron captures to identify and quantify the composition of the matrix. An indicator from its chlorine content is then deduced in order to choose the calibration coefficient which best represents the real composition of the matrix. This document firstly presents the needs of control and characterization of radioactive objects, and the means used in the field of nuclear measurement. Emphases is put in particular on the Active Neutron Interrogation method. The matrices of interest are those made of light technological waste (density {<=} 0,4 g/cm{sup 3}) containing hydrogenated and chlorinated materials. The advantages of gamma-rays emitted by neutron captures for the determination of a chlorine content indicator of the matrices and the principles of the correction method are then explained. Measurements have been firstly realized with an existing Neutron Interrogation device (PROMETHEE 6). Such measurements have proven its inadequacy: no signal from the matrix hydrogen was detected, due to an intense signal from the polyethylene contained in some cell elements. Moreover, the matrix chlorine content appeared difficult to be measured. A new and specific device, named REGAIN and dedicated to active gamma-rays spectrometry, was defined with the Monte-Carlo N-Particle (MCNP) code. The experiments conducted with this new device made it possible to detect the

  6. Electronic sorting of radioactive ores; Triage electronique des minerais radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    Sandier, J.

    1958-01-15

    Electronic sorting of radioactive ores consists in passing the rock lumps, after sieving, one by one in front of radioactivity detectors; these detectors command electromechanical systems which class the ores according to their radioactivity level. This note sets on the state of progress of the work going on at the D.R.E.M.: use of scintillometers for γ-ray detection, with circuits carrying magnetic memories to improve their operation; results of laboratory and semi-industrial tests on several deposits; description of the material, data on the first factory project; notes on the financial returns of the process. A description is also given of the electronic sorting material used skip by skip for a first rough classification of the ores according to their content, as they leave the shaft. (author) [French] Le triage electronique des minerais radioactifs consiste a faire passer, apres criblage, les cailloux un par un devant des detecteurs de radioactivite; ces detecteurs commandent des systemes electromecaniques qui classent les minerais selon leur niveau de radioactivite. La note expose l'etat d'avancement des travaux en cours a la D.R.E.M: utilisation des scintillometres pour la detection des rayonnements γ, de circuits comportant des memoires magnetiques pour ameliorer le fonctionnement; resultats d'essais de laboratoire et semi-industriels sur plusieurs gisements; description du materiel, donnees sur le premier projet d'usine; notes sur la rentabilite du procede. Est egalement decrit le materiel de triage electronique skip par skip utilise pour une premiere classification grossiere des minerais selon leurs teneurs, des la sortie des puits. (auteur)

  7. The Practice of Waste Disposal in the United Kingdom Atomic Energy Authority; Methodes Employees par l'Atomic Energy Authority du Royaume-Uni pour Eliminer les Dechets Radioactifs; 041f 041e 0420 042f 0414 041e 041a 0423 0414 ; Sistemas de Evacuacion de Desechos en la United Kingdom Atomic Energy Authority

    Energy Technology Data Exchange (ETDEWEB)

    Dunster, H. J.; Wix, L. F.U. [United Kingdom Atomic Energy Authority, Health and Safety Branch (United Kingdom)

    1960-07-01

    The United Kingdom Atomic Energy Authority operates establishments in locations ranging from the South of England to the North coast of Scotland. The functions of these establishments include the production and processing of nuclear fuels, the production of electricity and isotopes for commercial sale, the development of new types of reactors and the conduct of research in all the associated fields. The Authority therefore has a wide variety of wastes to deal with and they arise in a number of different places. The main high-activity wastes, both liquid and solid, are stored in special tanks and containers, while the low-activity large-volume liquid wastes are released in carefully controlled amounts to the sea or to rivers. Low-and medium- activity solid wastes are buried in selected areas where there will be no interference with water supplies, or sunk on to the sea bed. The paper summarizes the methods in use and gives typical quantities of liquid and solid waste arising annually for disposal by the various methods. (author) [French] Les divers etablissements de VAtomic Energy Authority du Royaume-Uni sont echelonnes entre le sud de l'Angleterre et la cote septentrionale de l'Ecosse. Ces etablissements sont notamment charges de la fabrication et du traitement des combustibles nucleaires, de la production d'electricite et de la production d'isotopes a des fins commerciales, de la mise au point de nouveaux modeles de reacteurs et des recherches effectuees dans tous les domaines connexes. L' Atomic Energy Authority doit donc proceder, en plusieurs points du territoire, a l'elimination de toute une serie de dechets radioactifs d'origines diverses. Les principaux dechets, liquides et solides, a radioactivite elevee sont enfermes dans des reservoirs et recipients speciaux, tandis que les volumineux dechets liquides a faible radioactivite sont evacues, par quantites soigneusement controlees, dans la mer ou les cours d'eau. Les dechets solides, de radioactivite faible

  8. Safety apparatus for serious radioactive accidents (1962); Materiel d'intervention en cas d'accident radioactif grave (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Estournel, R; Rodier, J [Commissariat a l' Energie Atomique, Centre de Production de Plutonium, Marcoule (France). Centre d' Etudes Nucleaires

    1962-07-01

    In the case of a serious radioactive accident, radioactive dust and gases may be released into the atmosphere. It is therefore necessary to be able to evaluate rapidly the importance of the risk to the surrounding population, and to be able to ensure, even in the event of an evacuation of the Centre, the continuation of the radioactivity analyses and the decontamination of the personnel. For this, the Anti-radiation Protection Service at Marcoule has organised mobile detection teams and designed a mobile laboratory and a mobile shower-unit. After describing the duty of the mobile teams, the report gives a description of the apparatus which would be used at the Marcoule Centre in the case of a serious radioactive accident. The method of using this apparatus is given. (authors) [French] Lors d'un accident radioactif grave, des poussieres et des gaz radioactifs peuvent etre relaches dans l'atmosphere. II est alors indispensable d'evaluer rapidement l'importance du risque couru par les populations environnantes, et de pouvoir assurer, meme dans le cas de l'evacuation du Centre, la poursuite des analyses radioactives et la decontamination du personnel. Pour cela, le Service de Protection contre les Radiations du Centre de Marcoule a mis sur pied des equipes mobiles de detection et realise une semi-remorque laboratoire ainsi qu'une semi-remorque douches. Apres avoir defini la mission des equipes mobiles, le rapport donne la description du materiel d'intervention qui serait mis en oeuvre par le Centre de Marcoule dans le cas d'un accident radioactif grave. Il precis le mode d'utilisation de ce materiel. (auteurs)

  9. Psychological Perspectives on Interrogation.

    Science.gov (United States)

    Vrij, Aldert; Meissner, Christian A; Fisher, Ronald P; Kassin, Saul M; Morgan, Charles A; Kleinman, Steven M

    2017-11-01

    Proponents of "enhanced interrogation techniques" in the United States have claimed that such methods are necessary for obtaining information from uncooperative terrorism subjects. In the present article, we offer an informed, academic perspective on such claims. Psychological theory and research shows that harsh interrogation methods are ineffective. First, they are likely to increase resistance by the subject rather than facilitate cooperation. Second, the threatening and adversarial nature of harsh interrogation is often inimical to the goal of facilitating the retrieval of information from memory and therefore reduces the likelihood that a subject will provide reports that are extensive, detailed, and accurate. Third, harsh interrogation methods make lie detection difficult. Analyzing speech content and eliciting verifiable details are the most reliable cues to assessing credibility; however, to elicit such cues subjects must be encouraged to provide extensive narratives, something that does not occur in harsh interrogations. Evidence is accumulating for the effectiveness of rapport-based information-gathering approaches as an alternative to harsh interrogations. Such approaches promote cooperation, enhance recall of relevant and reliable information, and facilitate assessments of credibility. Given the available evidence that torture is ineffective, why might some laypersons, policymakers, and interrogation personnel support the use of torture? We conclude our review by offering a psychological perspective on this important question.

  10. Desirable New Geologic Research in Support of Radioactive Waste Disposal as Indicated by Hanford Experience; Nouvelles Recherches Geologiques Souhaitables au Sujet de l'Elimination des Dechets Radioactifs, Selon les Indications Fournies par l'Experience de Hanford; 041f 0420 041e 0412 0415 0414 ; Nuevas Investigaciones Geologicas que Convendria Hacer para Facilitar la Evacuacion de Desechos Radiactivos Siguiendo las Indicaciones Proporcionadas por las Experiencias Efectuadas en Hanford

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Randall E. [Hanford Laboratories, Hanford Atomic Products Operation, General Electric Company, Richland, WA (United States)

    1960-07-01

    Hanford consiste a intercaler le plus grand nombre possible de structures geologiques entre les lieux d'elimination et les points les plus proches d'irradiation eventuelle des populations. Selon la decontamination de Simpson, ce procede fait appel aux notions de temporisation et de desintegration. Les problemes qui se posent a Hanford pour l'elimination des dechets portent sur les points suivants : - 1. l'inexactitude des donnees geologiques quantitatives; 2. l'absence de terrains isotropes et homogenes; 3. la necessite de determiner l'importance quantitative de l'ecart des caracteristiques geologiques et hydrologiques, par rapport a la jnpyexmejj ,4. la necessite de determiner et de mesurer les parametres interessants. Le memoire donne des exemples, pris a Hanford, qui illustrent les points ci-dessus. On a fore 557 puits d'une profondeur totale de 33.000 metres, mais les indications obtenues doivent etre utilisees avec prudence. Les etudes courantes des proprietes aquiferes des sols n'ont qu'une valeur limitee, car les donnees relatives a la permeabilite des differentes structures dans toutes les directions sont presentees globalement sous forme de valeurs moyennes. Les etudes fondees sur les echangea d'ions fournissent des donnees quantitatives d'un interet immediat qui peuvent aider a interpreter les caracteristiques geologiques. Les etudes hydrologiques, associees aux recherches geochimiques et aux donnees geologiques, permettent d'expliquer logiquement l'influence des structures geologiques sur les mouvements des eaux souterraines. L'enfouissement des dechets radioactifs n'est ni une panacee ni une pratique a redouter. A Hanford, en combinant les donnees obtenues par les geologues, les-hydrologistes, les geochimistes et les mathematiciens, on a pu parvenir a de bons resultats en matiere d'enfouissement sans danger des dechets. Il reste neanmoins beaucoup a faire. (author) [Spanish] La evacuacion de desechos radiactivos en el subsuelo depende de la estructura

  11. Interrogation: General vs. Local.

    Science.gov (United States)

    Johnson, Jeannette

    This paper proposes a set of hypotheses on the nature of interrogration as a possible language universal. Examples and phrase structure rules and diagrams are given. Examining Tamazight and English, genetically unrelated languages with almost no contact, the author distinguishes two types of interrogation: (1) general, querying acceptability to…

  12. Interrogating Planar Cyclooctatetraenes

    DEFF Research Database (Denmark)

    Hensel, Thomas

    ]circulenes were established. The antiaromaticity of the formal COT core of the hetero[8]circulenes was interrogated by comparison of the respective 13C-NMR carbon shifts with those of 3,6-dimethoxycarbazole (the starting material), tetrahydroxy intermediate and literature values. No uniform paratropic...

  13. Modeling and Interrogative Strategies.

    Science.gov (United States)

    Denney, Douglas R.

    Three studies to determine the effects of adult models on interrogative strategies of children (ages 6-11) are reviewed. Two issues are analyzed: (1) the comparative effectiveness of various types of modeling procedures for changing rule-governed behaviors, and (2) the interaction between observational learning and the developmental level of the…

  14. The treatment and conditioning of solid radioactive waste (1962); Le traitement et le conditionnement des dechets radioactifs solides (1982)

    Energy Technology Data Exchange (ETDEWEB)

    Cerre, P; Mestre, E [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1962-07-01

    Previous studies, the results of which have been confirmed by experiments, have led us to build a semi-industrial plant for the treatment and coating of solid radioactive waste. This report details the means at our disposal in a pilot plant which, apart from being used for tests, was also routine-operated. It is thus possible to give also an appreciation of its operation in this report. (authors) [French] Les etudes anterieures, dont les resultats ont ete confirmes par des essais, nous ont conduits a realiser une installation semi-industrielle de traitement et d'enrobage des dechets radioactifs solides. Le rapport a pour but de preciser les moyens mis a notre disposition dans une unite pilote qui, outre son role de banc d'essai, a pu etre exploitee en routine. C'est donc aussi un bilan de son exploitation qui est presente. (auteurs)

  15. Suicidality and interrogative suggestibility.

    Science.gov (United States)

    Pritchard-Boone, Lea; Range, Lillian M

    2005-01-01

    All people are subject to memory suggestibility, but suicidal individuals may be especially so. The link between suicidality and suggestibility is unclear given mixed findings and methodological weaknesses of past research. To test the link between suicidality and interrogative suggestibility, 149 undergraduates answered questions about suicidal thoughts and reasons for living, and participated in a direct suggestibility procedure. As expected, suggestibility correlated with suicidality but accounted for little overall variance (4%). Mental health professionals might be able to take advantage of client suggestibility by directly telling suicidal persons to refrain from suicidal thoughts or actions.

  16. Analytical chemistry equipment for radioactive products; Installation de chimie analytique pour produits radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    Douis, M; Guillon, A; Laurent, H; Sauvagnac, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1959-07-01

    The report deals with a shielded enclosure, hermetic, for analytical examination and handling of radioactive products. Remote handling for the following is provided: pipette absorption - weighing - centrifuging - desiccation - volumetric - pH measurement - potentiometric - colorimetric - polarographic. The above list is not restrictive: the enclosure is designed for the rapid installation of other equipment. Powerfully ventilated and screened to 400 m-curies long life fission product levels by 5 cm of lead, the enclosure is fully safe to the stated level. (author) [French] La presente communication decrit une enceinte etanche et blindee permettant un travail et un controle analytique sur des produits radioactifs. Les techniques suivantes sont adaptees pour une manipulation a distance: pipettage, pesees, centrifugation, dessiccation, volumetrie, mesure de pH, potentiometrie, colorimetrie, polarographie. Cette liste n'est pas limitative. La conception de l'installation permet la mise en place rapide d'autres appareils. Protegee par 5 cm de plomb et fortement ventilee, elle donne toute securite de manipulation jusqu'a un niveau d'activite 400 mcuries en produits de fission a vie longue. (auteur)

  17. Measurement of radioactive isotopes by {gamma} and x rays spectrometry with INa crystals. application to radiochemistry of some fission and activation products; Mesures d'isotopes radioactifs par spectrometrie {gamma} et x a l'aide de cristaux INa. application a la radiochimie de certains produits de fission et d'activation

    Energy Technology Data Exchange (ETDEWEB)

    Simonet, P; Boile, G; Simonet, G [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-07-01

    The measurement of an number of atoms N may be obtained by detection of one {gamma} ray emitted if its branching ratio K{sub E} is known (number of E energy {gamma} transitions/number of disintegrations). N = A/{lambda} N{sub {gamma}}{sub E} / (K{sub E} * {lambda}) This measurement is effectuated in well-defined geometry, {gamma} rays emitted by the source are detected by a calibrated NaI crystal which is connected to a photomultiplier delivering electric impulses analysed by a multichannel analyser. Crystals are chosen according to energy, intensity of measured rays and of background. Calibration is established with standard sources or by total absolute efficiency of a definite crystal. Half-life, energy of measured photopeak branching ratio have been determined for these isotopes: Fission products: {sup 95}Zr, {sup 95}Nb, {sup 99}Mo, {sup 103}Ru, {sup 106}Ru, {sup 111}Ag, {sup 115}Cd, {sup 115m}Cd, {sup 132}Te, {sup 129m}Te, {sup 134}Cs, {sup 136}Cs, {sup 137}Cs, {sup 140}Ba, {sup 140}La. Rare earth elements: {sup 91}Y, {sup 141}Ce, {sup 144}Ce, {sup 147}Nd, {sup 156}Eu. Products from reactions (n, {gamma}) (n, 2n): 1{sup 10}Ag, {sup 124}Sb, {sup 239}Np, {sup 237}U, {sup 241}Am. (authors) [French] La mesure du nombre d'atomes N d'un isotope peut s'effectuer sur un rayonnement {gamma} si l'on connait le rapport d'embranchement K{sub E} (nombre de rayonnements {gamma} d'energie E/nombre de desintegrations). N = A/{lambda} N{sub {gamma}}{sub E} / (K{sub E} * {lambda}) La mesure s'effectue en geometrie definie; les rayonnements {gamma} emis par la source sous mylar sont detectes par un cristal INa etalonne en fonction de l'energie, lequel est relie a un photomultiplicateur delivrant des impulsions electriques qui seront analysees par un selecteur multicanaux. La connaissance de la distribution theorique (effet photoelectrique, compton, paires, retrodiffusion, echappement... ) permet de determiner qualitativement si les elements sont purs, et de faire une mesure sur

  18. Applicability of ICRP principles for safety analysis of radioactive waste geological storage; Etude de l'applicabilite des principes de la CIPR a l'analyse de surete du stockage geologique des dechets radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    Lombard, J; Hubert, P; Pages, P

    1987-07-01

    Since the beginning of the eighties, the international organisations have established new recommendations for radioactive waste management. These recommendations are based on two principles. First is concerned with limitation of risks. It should be shown that the risk is smaller than the limit of acceptance. Practically only on risk criterion is foreseen. The principle demands, if a storage causes an event of individual risk (defined as a product of probability of occurrence and the probability of its causing severe health effects) is higher than 10 {sup -5} per year, this storage is not acceptable. The second principle deals with optimisation, demands that the level of protection related to the storage should be determined by a comparative process choosing the best compromise between the price of protection and the residual risk. These recommendations, especially the second one, differ from the safety analysis principles adopted presently in France and other countries. This study analyzes the advantages and potential inconveniences related to the introduction of the second principle. (author) [French] Depuis le debut des annees quatre vingt, de nouvelles recommandations ont ete formulees par les organismes internationaux (AIEA, OCDE, OIPR) en matiere de gestion des dechets radioactifs. Ces recommandations s'articulent autour de deux principes. Le premier, est celui de limitation des risques. II s'agit de demontrer que le risque est inferieur a un seuil d'acceptabilite. En pratique, un seul critere de risque est envisage. Ainsi le principe stipule, que si un stockage est a I'origine d'evenements conduisant a un risque individuel (defini comme le produit de a probabilite d'occurrence de l'evenement par Ia probabilite que cet evenement cause un effet sanitaire grave) total annuel superieur a 10{sup -5}/an, alors le risque lie a ce stockage est juge inacceptable. Le second, dit d'optimisation, stipule que le niveau de protection associe a un stockage (donc les

  19. Study of radio-active ions in the atmosphere; Etude des ions radioactifs de l'atmosphere

    Energy Technology Data Exchange (ETDEWEB)

    Renoux, A [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1965-01-01

    A comparative study is made of active, deposits of radon and thoron in suspension in the atmosphere by means of {alpha} radiation counting, using ZELENY tubes, scattering equipment, filter papers or membranes. It has been possible to show the existence of small and large ions which are negative and positive, as well as of neutral radio-active nuclei; their properties are studied. A theoretical interpretation of the results is presented. The average content of radon (using the Ra A concentration) and of Th B in the air has been determined. The radioactive equilibrium between radon and its daughter products in atmospheric air are examined. The techniques developed for active radon and thoron deposits are applied to the study of artificial radio-activity, the analyses being carried out by means of {gamma} spectrometry. (author) [French] On effectue une etude comparative entre les depots actifs du radon et du thoron en suspension dont l'atmosphere a l'aide de comptages de rayonnement {alpha}, en utilisant des tubes de ZELENY, une batterie de diffusion, des papiers filtres ou des membranes. On met ainsi en evidence la presence de petits et gros ions negatifs et positifs, ainsi que celle de noyaux neutres radioactifs, et on etudie leurs proprietes. Une Interpretation theorique des resultats obtenus est developpee. On determine la teneur moyenne de l'air en radon (a partir de la concentration en Ra A) et en Th B. L'equilibre radioactif entre le radon et ses descendants, dans l'air atmospherique, est examine. Les Techniques mises au point pour les depots actifs du radon et du thoron sont appliquees a l'etude de la radioactivite artificielle, les depouillements s'effectuant par spectrometrie {gamma}. (auteur)

  20. Radio-tracer techniques in the study of corrosion by molten fluorides; Etude, a l'aide d'indicateurs radioactifs, de la corrosion provoquee par les fluorures fondus; Primenenie metodov radioaktivnykh indikatorov nrn izuchenii korrozii, prichinyaemoj rasplavlennymi ftoristymi soedineniyami; Estudio con indicadores radiactivos de la corrosion ocasionada por fluoruros fundidos

    Energy Technology Data Exchange (ETDEWEB)

    Grimes, W R; Watson, G M; DeVan, J H; Evans, R B [Oak Ridge National Laboratory, Oak Ridge, TN (United States)

    1962-03-15

    de fluorures fondus contenant, des substances reductibles, le chrome est oxyde selectivement et elimine de l'alliage. En utilisant comme radioindicateur le chrome-51, les auteurs du memoire ont evalue les coefficients d'autodiffusion du chrome dans l'Inconel et l'Inor-8 et verifie dans quelle mesure les valeurs obtenues sont applicables aux alliages exposes a la corrosion. Les auteurs ont calcule les coefficients globaux: 1) en mesurant le passage du chrome-51 (employe sous forme de CrF{sub 2}) des capsules d'alliage aux fluorures non corrosifs fondus; 2) en comparant la radioactivite totale mesuree des echantillons d'alliage exposes avec celle du sel auquel ils avaient ete exposes. Ils ont calcule en outre des coefficients en mesurant les profils de concentration de l'indicateur par polissages electrolytiques successifs des echantillons. Les coefficients globaux et ceux qui ont ete obtenus par polissage electrolytique concordent parfaitement pour l'Inconel a des temperatures elevees et pour l'Inor-8 a toutes les temperatures. Pour les temperatures inferieures a 750{sup o}C, les coefficients obtenus par polissage electrolytique de l'Inconel sont superieurs aux coefficients globaux; dans ce cas, le processus de diffusion dans la masse n'est pas uniforme. Il y a toujours concordance satisfaisante entre les coefficients globaux de diffusion et les coefficients obtenus par extrapolation des donnees publiees au sujet d'alliages Cr-Ni generalement analogues, a des temperatures plus elevees. Les auteurs se sont servis de deux anneaux polythermiques d'Inor-8 pour faire circuler une masse de fluorures fondus non corrosifs contenant du chrome-51 (sous forme de CrF{sub 2}). Ils ont sacrifie l'un des circuits pour evaluer la quantite de {sup 51}Cr absorbee par l'alliage, et utilise l'autre pour faire circuler un melange fondu contenant du FeF{sub 2} et mesurer l'elimination du chrome de l'alliage. Les resultats obtenus concordent assez, bien avec les donnees fournies par les

  1. Police practices and perceptions regarding juvenile interrogation and interrogative suggestibility.

    Science.gov (United States)

    Meyer, Jessica R; Reppucci, N Dickon

    2007-01-01

    Recent media coverage has highlighted cases in which young suspects were wrongly convicted because they provided interrogation-induced false confessions. Although youth may be more highly suggestible and easily influenced by authority than adults, police are trained to use the same psychologically coercive and deceptive tactics with youth as with adults. This investigation is the first standard documentation of the reported interrogation practices of law enforcement and police beliefs about the reliability of these techniques and their knowledge of child development. Participants were 332 law enforcement officers who completed surveys about interrogation procedures and developmental issues pertaining to youth. Results indicated that, while police acknowledge some developmental differences between youth and adults, there were indications that (1) how police perceive youth in general and how they perceive and treat them in the interrogation context may be contradictory and (2) their general view is that youth can be dealt with in the same manner as adults. Copyright (c) 2007 John Wiley & Sons, Ltd.

  2. The treatment of effluents; Ameliorations apportees aux traitements des residus radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    Wormser, G; Rodier, J; Robien, E de; Fernandez, N [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1964-07-01

    resins are used in the sodium form; the regeneration is carried out using a sodium salt solution which, after decontamination by coprecipitation is used again. With this process it is possible to use a smaller volume of sludge. 2 - The use of a natural evaporator. This process uses atmospheric air which is not saturated with water vapour and which is at a normal temperature, in order to extract water from the aqueous effluents. (authors) [French] Depuis plusieurs annees, le Commissariat a l'Eneregie Atomique Francais s'est penche avec interet sur les problemes poses par les effluents radioactifs. Les hautes activites n'ayant pas encore recu de solution definitive, nous nous bornerons a traiter, dans cette communication, que des realisations et des recherches relatives aux effluents faiblement et moyennement actifs. Dans le domaine des realisations, diverses stations de traitement ont ete construites en France; nous en ferons une breve enumeration, tout en faisant ressortir les nouveautes les plus importantes. C'est ainsi que nous presenterons plus specialement les dernieres stations de traitement mises en oeuvre (Grenoble, Fontenay-aux-Roses, Cadarache). De I'ensemble de ces realisations nouvelles, nous traiterons d'une maniere un peu plus approfondie, les trois sujets suivants: 1 - Atelier de conditionnement par bitumage des boues provenant de la concentration des radio-nucleides. 2 - Atelier de traitement des dechets solides radioactifs et combustibles par incineration. 3 - Ensemble de concentration effluents liquides radioactifs par evaporation. Dans le domaine de la recherche, de nombreuses voies ont ete abordees; nous en ferons I'inventaire. Il s'agit, dans la plupart des cas, de la concentration des radio-nucleides en vue d'un stockage pratique et peu onereux, concentration associee a une decontamination efficace, et Ie meilleur marche possible, des liquides aqueux, en vue de leur rejet. Pour l'amelioration des traitements aboutissant a la concentration des radio

  3. Interrogating personhood and dementia

    Science.gov (United States)

    Higgs, Paul; Gilleard, Chris

    2016-01-01

    ABSTRACT Objectives: To interrogate the concept of personhood and its application to care practices for people with dementia. Method: We outline the work of Tom Kitwood on personhood and relate this to conceptualisations of personhood in metaphysics and in moral philosophy. Results: The philosophical concept of personhood has a long history. The metaphysical tradition examines the necessary and sufficient qualities that make up personhood such as agency, consciousness, identity, rationality and second-order reflexivity. Alternative viewpoints treat personhood as a matter of degree rather than as a superordinate category. Within moral philosophy personhood is treated as a moral status applicable to some or to all human beings. Conclusion: In the light of the multiple meanings attached to the term in both metaphysics and moral philosophy, personhood is a relatively unhelpful concept to act as the foundation for developing models and standards of care for people with dementia. Care, we suggest, should concentrate less on ambiguous and somewhat abstract terms such as personhood and focus instead on supporting people's existing capabilities, while minimising the harmful consequences of their incapacities. PMID:26708149

  4. A new class of medicament: radioactivity isotopes (1962); Une nouvelle classe de medicaments: les isotopes radioactifs (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, Y. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1962-07-01

    Very many radioelement are used in medicine, either for diagnosis or as therapeutics. The development of medicine has entailed an increase in the number of application of radioactive isotopes. Firstly used in the form of simple inorganic molecules for diagnosis or as anticancer therapeutics, radioelements are now used for labelling organic molecules, allowing functional specific studies of any kind of nature. Their production is made difficult by their radio-active properties. Their pharmaceutical properties, determined by tests and controls, depend either from radiochemistry and from medicine. The author reminds, in this report, the methods for the preparation and analysis, and set out the medical application. (author) [French] De tres nombreux radioelements trouvent une application en medecine humaine, soit dans le diagnostic, soit en therapeutique. L'evolution de la medecine entraine un accroissement du champ d'application des isotopes radioactifs. D'abord utilises sous forme de molecules minerales simples, pour les diagnostics ou des therapeutiques anticancereuses, les radioelements sont maintenant introduits dans des molecules organiques qui permettent des etudes fonctionnelles specifiques de toute nature. Leur fabrication est compliquee par leurs proprietes radioactives. Leurs caracteristiques pharmaceutiques determinees par des essais et controles, sont liees d'une part a la radiochimie, d'autre part a la medecine. L'auteur rappelle, dans cet expose, les methodes de preparation et d'analyse et aborde les applications medicales. (auteur)

  5. A new class of medicament: radioactivity isotopes (1962); Une nouvelle classe de medicaments: les isotopes radioactifs (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, Y [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1962-07-01

    Very many radioelement are used in medicine, either for diagnosis or as therapeutics. The development of medicine has entailed an increase in the number of application of radioactive isotopes. Firstly used in the form of simple inorganic molecules for diagnosis or as anticancer therapeutics, radioelements are now used for labelling organic molecules, allowing functional specific studies of any kind of nature. Their production is made difficult by their radio-active properties. Their pharmaceutical properties, determined by tests and controls, depend either from radiochemistry and from medicine. The author reminds, in this report, the methods for the preparation and analysis, and set out the medical application. (author) [French] De tres nombreux radioelements trouvent une application en medecine humaine, soit dans le diagnostic, soit en therapeutique. L'evolution de la medecine entraine un accroissement du champ d'application des isotopes radioactifs. D'abord utilises sous forme de molecules minerales simples, pour les diagnostics ou des therapeutiques anticancereuses, les radioelements sont maintenant introduits dans des molecules organiques qui permettent des etudes fonctionnelles specifiques de toute nature. Leur fabrication est compliquee par leurs proprietes radioactives. Leurs caracteristiques pharmaceutiques determinees par des essais et controles, sont liees d'une part a la radiochimie, d'autre part a la medecine. L'auteur rappelle, dans cet expose, les methodes de preparation et d'analyse et aborde les applications medicales. (auteur)

  6. The dynamic nature of interrogation.

    Science.gov (United States)

    Kelly, Christopher E; Miller, Jeaneé C; Redlich, Allison D

    2016-06-01

    Building on a substantial body of literature examining interrogation methods employed by police investigators and their relationship to suspect behaviors, we analyzed a sample of audio and video interrogation recordings of individuals suspected of serious violent crimes. Existing survey research has focused on the tactics reportedly used, at what rate, and under what conditions; observational studies detail which methods are actually employed. With a few notable exceptions, these foundational studies were static examinations of interrogation methods that documented the absence or presence of various approaches. In the present study, we cast interrogation as a dynamic phenomenon and code the recordings in 5-min intervals to examine how interrogation methods and suspect cooperation change over time. Employing the interrogation taxonomy framework, particularly 4 discrete domains-rapport and relationship building, emotion provocation, presentation of evidence, and confrontation/competition-we found that the emphasis of the domains varied across interrogations and were significantly different when suspects confessed versus when they denied involvement. In regression models, suspect cooperation was positively influenced by the rapport and relationship building domain, though it was negatively impacted by presentation of evidence and confrontation/competition. Moreover, we found that the negative effects of confrontation/competition on suspect cooperation lasted for up to 15 min. The implications of the findings for practice and future research include the benefits of a rapport-based approach, the deleterious effects of accusatorial methods, and the importance of studying when, not just if, certain interrogation techniques are employed. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  7. Epithermal interrogation of fissile waste

    International Nuclear Information System (INIS)

    Coop, K.L.; Hollas, C.L.

    1996-01-01

    Self-shielding of interrogating thermal neutrons in lumps of fissile material can be a major source of error in transuranic waste assay using the widely employed differential dieaway technique. We are developing a new instrument, the combined thermal/epithermal neutron (CTEN) interrogation instrument to detect the occurrence of self- shielding and mitigate its effects. Neutrons are moderated in the graphite walls of the CTEN instrument to provide an interrogating flux of epithermal and thermal neutrons. The induced prompt fission neutrons are detected in proportional counters. We report the results of measurements made with the CTEN instrument, using minimal and highly self-shielding plutonium and uranium sources in 55 gallon drums containing a variety of mock waste matrices. Fissile isotopes and waste forms for which the method is most applicable, and limitations associated with the hydrogen content of the waste package/matrix are described

  8. Interrogative suggestibility in opiate users.

    Science.gov (United States)

    Murakami, A; Edelmann, R J; Davis, P E

    1996-09-01

    The present study investigated interrogative suggestibility in opiate users. A group of patients undergoing a methadone detoxification programme in an in-patient drug treatment unit (Detox group, n = 21), and a group of residents who had come off drugs and were no longer suffering from withdrawal syndrome (Rehab group, n = 19) were compared on interrogative suggestibility and various other psychological factors. Significant differences were found between the two groups, with the Detox group having more physical and psychological problems, and a higher total suggestibility score in comparison with the Rehab group. These findings are discussed in relation to the context of police interrogations and the reliability of confessions made by suspects and witnesses dependent on opiates.

  9. Dating methods based on the radioactive disequilibrium (1961); Methodes de chronologie par le desequilibre radioactif (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Coquema, C; Coulomb, R; Goldsztein, M; Schiltz, J C [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1961-07-01

    The existence in the uranium families of two long-life descendants: ionium (half-life 80000 years) and protactinium (half-life 32000 years), together with the differences in geochemical behaviour of the various natural radio-elements, particularly thorium, make it possible to envisage several models of geological time-scales covering-periods from 0 to 500000 years The theory of two of the most important models i s developed and methods are described for making radiochemical measurements on the various nuclides which are essential for resolving these models (U{sup 238}, Th{sup 234}, Th{sup 230}, Ra{sup 226}, Pa{sup 231}, Th{sup 232}, Th{sup 228}, Po{sup 210}) An example of dating is given in the case of a secondary mineralisation on a weathered portion of a deposit in the Limouzat (Forez). Samples of autunite and chalcolite taken at different levels of the mine were calculated to be between 30000 and 240000 years old. (authors) [French] L'existence dans les familles de l'uranium de deux descendants a vie longue: ionium (periode 80000 ans) et protactinium (periode 32000 ans), ainsi que les differences tie comportement geochimique des divers radioelements naturels, en particulier du thorium, permettent d'envisager plusieurs modeles d'echelles geochronologiques couvrant un domaine allant de 0 a 500000 ans. Nous developpons la theorie de deux de ces modeles les plus importants, et decrivons les methodes de dosage radiochimiques des divers nucleides dont la connaissance est necessaire a la resolution des modeles ({sup 238}U, {sup 234}Th, {sup 230}Th, {sup 226}Ra, {sup 231}Pa, {sup 232}Th, {sup 228}Th, {sup 210}Po). On donne un exemple de chronologie d'une mineralisation secondaire sur la partie alteree du gisement du Liznouzat (Forez). Des echantillons d'autunite et de chalcolite pris a differents niveaux de la mine ont pu etre dates de 30000 a 240000 ans. (auteurs)

  10. Code of Practice on the International Transboundary Movement of Radioactive Waste; Code De Bonne Pratique Sur Le Mouvement Transfrontiere International De Dechets Radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1990-11-03

    On 21 September 1990, the General Conference, by resolution GC(XXXIV)/RES/530, adopted a Code of Practice on the International Transboundary Movement of Radioactive Waste and requested the Director General - inter alia - to take all necessary steps to ensure wide dissemination of the Code of Practice at both the national and the international level. The Code of Practice was elaborated by a Group of Experts established pursuant to resolution GC(XXXII)/RES/490 adopted by the General Conference in 1988. The text of the Code of Practice is reproduced herewith for the information of all Member States [French] Le 21 septembre 1990, la Conference generale, par la resolution GC(XXXIV)/RES/530, a adopte le Code de bonne pratique sur le mouvement transfrontiere international de dechets radioactifs et a prie le Directeur general-notamment-de prendre toutes les mesures necessaires pour assurer une large diffusion du Code de bonne pratique aux niveaux tant national qu'international. Le Code de bonne pratique a ete elabore par un groupe d'experts cree en application de la resolution GC(XXXII)/RES/490 adoptee par la Conference generale en 1988. Le texte du Code de bonne pratique est reproduit ci-apres pour l'information de tous les Etats Membres.

  11. Language style matching and police interrogation outcomes

    NARCIS (Netherlands)

    Richardson, Beth H.; Taylor, Paul J; Snook, Brent; Conchie, Stacey M.; Bennell, Craig

    2014-01-01

    This research examined the coordination of interrogator and suspects’ verbal behavior in interrogations. Sixty-four police interrogations were examined at the aggregate and utterance level using a measure of verbal mimicry known as Language Style Matching. Analyses revealed an interaction between

  12. 8 CFR 343b.3 - Interrogation.

    Science.gov (United States)

    2010-01-01

    ... 8 Aliens and Nationality 1 2010-01-01 2010-01-01 false Interrogation. 343b.3 Section 343b.3 Aliens... NATURALIZATION FOR RECOGNITION BY A FOREIGN STATE § 343b.3 Interrogation. When Form N-565 presents a prima facie... issuance of the certificate. Interrogation of the applicant shall be conducted before the application is...

  13. Determination of the concentration of {alpha} emitting radioactive aerosols; Mesure de la concentration des aerosols radioactifs emetteurs {alpha}

    Energy Technology Data Exchange (ETDEWEB)

    Labeyrie, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1953-06-15

    In the first part of this work the techniques used for the quantitative measurement of the concentrations of aerosols carrying short lived (radon or thoron daughters) or long lived (uranium) {alpha} radioactive emitters are described. In the second part the author investigates the problem of the determination of radon concentration in air by means of activity determinations on airborne dusts. Special reference is made to the measurement of the radon active deposit on two types of dusts (iron oxide (yellow) and uranium oxide) in small chambers (6 liters). In the third part are given data resulting from determinations of radon and thoron concentrations in atmospheric air in the south of Paris area using this method. (author) [French] Dans la premiere partie de ce travail on expose les techniques utilisees pour la mesure quantitative des concentrations d'aerosols contenant des emetteurs radioactifs {alpha}, tant pour ceux a vie courte (derives du radon ou du thoron) que pour ceux a vie longue (uranium). Dans la seconde partie on traite le probleme de la determination de la concentration de l'air en radon par la mesure de l'activite des poussieres ayant sejourne dans cet air. En particulier, on indique pour de petits volumes (6 litres) la proportion de depot actif du radon qui est fixee sur deux types de poussieres (limonite et oxyde d'uranium) en fonction de la concentration de celles-ci. Dans la troisieme partie on donne quelques exemples de mesure par cette methode de la concentration en radon et en thoron de l'atmosphere de la region parisienne. (auteur)

  14. Study of filterable materials and protection instruments by the use of radioactive aerosols; Etude de materiaux filtrants et d'appareils de protection a l'aide des aerosols radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    Billard,; Chevalier,; Pradel, [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    Many filtration problems can be studied by means of radioactive aerosols. For the investigations described in this paper we have chosen the solid disintegration products of radon, the radioactive gas formed from radium, because of the facilities of generation and measurement it offers. Radon and its daughters are in fact always present in the atmosphere in sufficient concentration for certain tests. In order to improve the sensitivity of the measurements, radon from uranium ore can be used. The technique of measuring by counting {alpha} particles is rapid and easy to employ. We have thus been able to define a test for filterable substances, and to check filtering installation and individual protection instruments. (author) [French] Les aerosols radioactifs permettent d'etudier de nombreux problemes de filtration. Pour les etudes decrites dans ce document, nous avons choisi les produits solides de desintegration du radon, gaz radioactif forme a partir du radium en raison des facilites de generation et de mesure. Le radon et ses descendants sont, en effet, toujours presents dans l'atmosphere en concentration suffisante pour certains essais. Pour ameliorer la sensibilite des mesures, il suffit d'utiliser le radon provenant de minerai d'uranium. La technique de mesure par comptage des particules {alpha} est rapide et facile a mettre en oeuvre. Nous avons pu ainsi definir un test pour les substances filtrantes et controler les installations de filtration et des appareils de protection individuelle. (auteur)

  15. AWG Filter for Wavelength Interrogator

    Science.gov (United States)

    Black, Richard J. (Inventor); Costa, Joannes M. (Inventor); Faridian, Fereydoun (Inventor); Moslehi, Behzad (Inventor); Sotoudeh, Vahid (Inventor)

    2015-01-01

    A wavelength interrogator is coupled to a circulator which couples optical energy from a broadband source to an optical fiber having a plurality of sensors, each sensor reflecting optical energy at a unique wavelength and directing the reflected optical energy to an AWG. The AWG has a detector coupled to each output, and the reflected optical energy from each grating is coupled to the skirt edge response of the AWG such that the adjacent channel responses form a complementary pair response. The complementary pair response is used to convert an AWG skirt response to a wavelength.

  16. Active interrogation using energetic protons

    International Nuclear Information System (INIS)

    Morris, Christopher L.; Chung, Kiwhan; Greene, Steven J.; Hogan, Gary E.; Makela, Mark; Mariam, Fesseha; Milner, Edward C.; Murray, Matthew; Saunders, Alexander; Spaulding, Randy; Wang, Zhehui; Waters, Laurie; Wysocki, Frederick

    2010-01-01

    Energetic proton beams provide an attractive alternative when compared to electromagnetic and neutron beams for active interrogation of nuclear threats because they have large fission cross sections, long mean free paths and high penetration, and they can be manipulated with magnetic optics. We have measured time-dependent cross sections and neutron yields for delayed neutrons and gamma rays using 800 MeV and 4 GeV proton beams with a set of bare and shielded targets. The results show significant signals from both unshielded and shielded nuclear materials. Measurements of neutron energies yield suggest a signature unique to fissile material. Results are presented in this paper.

  17. Interrogative suggestibility in patients with conversion disorders.

    Science.gov (United States)

    Foong, J; Lucas, P A; Ron, M A

    1997-09-01

    We tested the hypothesis that increased interrogative suggestibility may contribute to the shaping and maintaining of conversions symptoms. Interrogative suggestibility was measured in 12 patients with conversion disorder and 10 control patients with confirmed neurological disease matched for age, premorbid intelligence, and as closely as possible in terms of their neurological symptoms to the patients with conversion disorder. Our observations do not support the contention that individual differences in interrogative suggestibility are of importance in the etiology of conversion disorders.

  18. Bright Lights and Questions: Using Mutual Interrogation

    Science.gov (United States)

    Adam, Aishikin; Alangui, Willy; Barton, Bill

    2010-01-01

    Mutual Interrogation is a research methodology for ethnomathematics proposed by Alangui in 2006 in an attempt to avoid the potential inequality set up when a restricted cultural practice is viewed through the lens of the near-universal and highly developed research domain of mathematics. Using three significant examples of mutual interrogation in…

  19. Interrogative constructions in Danish Sign Language (DSL)

    DEFF Research Database (Denmark)

    Hansen, Julie

    This study investigates the primary types of interrogative constructions: Polar and content questions. The aim is to identify how and in which types of interrogative constructions the non-manual patterns described by Engberg-Pedersen (1993, 1998)are used. Furthermore, the aim is to identify...

  20. The Treatment of Cancer by a Radioactive Drug: Tritium-Labelled Tetra-Sodium 2-Methyl-1:4-Naphthaquinol Diphosphate; Traitement du Cancer par un Remede Radioactif: Le Diphosphate Tetrasodique de Methyl-2 Naphtoquinone-1,4 Tritie; 041b 0435 0447 0435 043d 0414 ; Tratamiento del Cancer con la Sal Tetrasodica del Acido 2-Metil-1,4-Naftoquinon Difosforico Marcada con Tritio

    Energy Technology Data Exchange (ETDEWEB)

    Marrian, D. H.; Marshall, Barbara; Mitchell, J. S.; Simon-Reuss, I. [Department of Radiotherapeutics, University of Cambridge, Cambridge (United Kingdom)

    1962-02-15

    The action of tetra-sodium 2-methyl-1: 4-naphthaquinoI diphosphate (''Synkavit''-Roche Products) as a radiosensitizer will be reviewed together with earlier methods of labelling this and similar molecules. The synthesis of this compound labelled with tritium has been accomplished so as to yield a radiochemically pure drug of specific activity 28 c/mmole (1 atom of tritium/molecule). It will be shown that this compound enters the living cell very rapidly both in-vivo and in-vitro and that cultures of malignant cells incorporate the label to a much greater extent than cultures of normal cells under identical conditions. Preliminary investigations on the use of this drug on patients with advanced, and often otherwise, refractory, malignant conditions will be described; uptake by the bone marrow is less than by the tumour, sometimes by a factor of 5. (author) [French] Les auteurs examinent l'action du diphosphate tetrasodique de methyl-2- naphtoquinone-1,4 ('Synkavit'-Produits Roche) comme radiosensibilisateur, ainsi que les methodes plus anciennes de marquage de ces molecules et de molecules analogues. On a fait la synthese de ce compose marque au tritium, de facon a obtenir un produit pharmaceutique radiochimiquement pur, dont l'activite specifique est de 28 curies par millimole (1 atome de tritium par molecule). Les auteurs demontrent que ce compose penetre tres rapidement dans la cellule vivante, tant in vivo qu'in vitro, et que les cultures de cellules malignes fixent l'indicateur dans une mesure beaucoup plus large que ne le feront les cellules normales dans les memes conditions. Les auteurs exposent les resultats de recherches preliminaires sur l'emploi de ce remede pour soigner des malades atteints de tumeurs malignes avancees et souvent refractaires a tout autre traitement. L'absorption par la moelle osseuse est inferieure, parfois de 5 fois, a l'absorption par la tumeur. (author) [Spanish] Los autores describen la accion radiosensibilizadora de la sal

  1. Wireless interrogation of passive antenna sensors

    International Nuclear Information System (INIS)

    Deshmukh, S; Huang, H

    2010-01-01

    Recently, we discovered that the resonant frequency of a microstrip patch antenna is sensitive to mechanical strains or crack presence in the ground plane. Based on this principle, antenna sensors have been demonstrated to measure strain and detect crack in metallic structures. This paper presents a wireless method to remotely interrogate a dual-frequency antenna sensor. An interrogation horn antenna was used to irradiate the antenna sensor with a linear chirp microwave signal. By implementing a light-activated switch at the sensor node and performing signal processing of the backscattered signals, the resonant frequencies of the antenna sensor along both polarizations can be measured remotely. Since the antenna sensor does not need a local power source and can be interrogated wirelessly, electric wiring can be eliminated. The sensor implementation, the signal processing and the experimental setup that validate the remote interrogation of the antenna sensor are presented. A power budget model has also been established to estimate the maximum interrogation range

  2. 32 CFR 637.21 - Recording interviews and interrogations.

    Science.gov (United States)

    2010-07-01

    ... ENFORCEMENT AND CRIMINAL INVESTIGATIONS MILITARY POLICE INVESTIGATION Investigations § 637.21 Recording interviews and interrogations. The recording of interviews and interrogations by military police personnel is...

  3. The Determination of Components of Radioactive Decay Mixtures by Computer Analysis of Count-Rate Data; Determination des Composants de Melanges Radioactifs en Decroissance par Analyse a l'Ordinateur des Resultats du Comptage; Opredelenie komponentov smesej radioaktivnogo raspada posredstvom analiza dannykh skorostej scheta s pomoshch'yu schetno-reshayushchego ustrojstva; Determinacion de los Componentes de Mezclas Radiactivas por Analisis de los Datos de Recuento Mediante Calculadoras

    Energy Technology Data Exchange (ETDEWEB)

    Airman, W. D.F.; Tyler, S. A.; Dipertand, M. H.; Sedlet, J. [Argonne National Laboratory, Argonne, IL (United States)

    1965-10-15

    measurements are made permit correlations between the data obtained and the total decay and growth rates. The development of the programme and the results obtained from theoretical and experimental data used to test it are discussed. (author) [French] Les composants d'un melange de n radioisotopes peuvent etre determines d'apres les variations de l'activite avec le temps, a condition que l'activite d'au moins n-1 elements se modifie de maniere appreciable au cours de la periode consideree, soit par la decroissance directe, soit par la croissance des produits de desintegration. Pour chaque melange, il est possible de predire un ensemble d'elements d'apres des facteurs tels que l'origine et l'evolution anterieure du melange et les techniques de separation chimique et de comptage utilisees. Si ces facteurs sont appliques de maniere convenable, l'ensemble suppose contiendra tous les elements que comporte effectivement le melange. On peut alors, soit formuler les equations de croissance ou de decroissance et les resoudre simultanement pour obtenir chaque element, soit determiner le melange sous forme graphique par extrapolation des parties lineaires de la courbe totale decroissance-croissance. Toutefois, lorsque le nombre d'elements est eleve ou que des schemas complexes de decroissance entrent en ligne de compte, il est impossible, soit d'appliquer l'une ou l'autre de ces techniques, soit d'evaluer les erreurs inherentes aux previsions. L'application de la methode des moindres carres permet d'identifier plus exactement les elements en decroissance que la methode consistant a n'utiliser que des equations simultanees. Les auteurs ont donc mis au point un programme d'ordinateur Fortran, fonde sur la methode des moindres carres (designe par le vocable CORD) et destine a resoudre le probleme general, a savoir: etant donne le taux de comptage pour un echantillon, les precurseurs et les schemas de decroissance possibles, toutes les constantes de decroissance et les caracteristiques de

  4. Catching the Cyber Spy: ARL's Interrogator

    National Research Council Canada - National Science Library

    Long, Kerry S

    2004-01-01

    The U.S. Army Research Laboratory has designed a network-based intrusion detection framework, Interrogator, which addresses the constantly changing threat environment that Department of Defense networks...

  5. Police interrogations through the prism of science

    Directory of Open Access Journals (Sweden)

    Igor Areh

    2016-03-01

    Full Text Available Several approaches can be employed for information gathering from human sources, differing in their theoretical basis, goals, realisation, and ethical acceptability. The paper critically presents and compares two prevalent approaches to suspect interrogation used by the police. The older, prevalent interrogation approach focuses on obtaining suspects’ incriminating statements and admissions, which severely elevates the risk of false confessions. Consequently, this interrogation approach is termed accusatorial or coercive since suspects are forced to admit to a crime. The newer interrogation approach is the information-gathering approach, also known as the investigative interview. It focuses on gathering accurate information in order to exclude or accuse a suspect in a criminal investigation. In comparison with coercive interrogation models, the information-gathering approach has a lower probability of false confessions since suspects are exposed to significantly lower levels of psychological pressure. Moreover, it is ethically more acceptable, has scientific grounds, enables the gathering of more accurate information, and has been found to be at least as effective as the coercive approach in criminal investigations. The investigative interview relies mainly on findings from social psychology. An analysis of coercive interrogation models reveals that they have no scientific basis and as such rely mainly on uncorroborated common-sense assumptions from authorities. In developed countries, coercive interrogation models are increasingly being replaced by the information-gathering approach, a trend connected with the enforcement of high human rights standards and a higher awareness of risks associated with coercive interrogation methods by the general public, academia, and professionals alike.

  6. Collection and processing of information in biological kinetics studies with radioactive tracers; Collecte et traitement de l'information dans les etudes de cinetique biologique avec traceurs radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    Remy, J; Lafuma, J [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1968-07-01

    The authors present an automatic method for the collection and treatment of information in biological kinetics experiments using radioactive tracers. The recording are made without any time constant on magnetic tape. The information recorded is sampled by a 400 channel multi-scale analyzer and transferred to punched cards. The digital analysis is done by an I.B.M. computer. The method is illustrated by an example: the hepatic fixation of colloidal gold in the pig. Its advantages and requirements are discussed. In the appendix are given the FORTRAN texts for two programmes used in treating the example presented. (authors) [French] Les auteurs presentent une methode automatique de collecte et de traitement de l'information dans les experiences de cinetique biologique utilisant les traceurs radioactifs. Les enregistrements sont realises sans constante de temps sur bande magnetique. L'information enregistree fait l'objet d'un echantillonnage a l'aide d'un analyseur a 400 canaux en mode multi-echelle puis est transferee sur cartes perforees. L'exploitation digitale est confiee a un ordinateur I.B.M.. La methode est illustree par un exemple d'etude de la fixation hepatique de l'or colloidal chez le porc. Ses avantages et ses exigences sont discutes. En annexe figurent les textes en FORTRAN de deux programmes utilises pour le traitement de l'exemple cite. (auteurs)

  7. Study of the behaviour of artificial radioactive aerosols. Applications to some problems of atmospheric circulation (1963); Etude du comportement dcs aerosols radioactifs artificiels. Applications a quelques problemes de circulation atmospherique (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Lambert, G. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-11-15

    The aim of this work, consists in the examination of the behaviour of radioactive aerosols produced in the atmosphere by nuclear explosions, in order to deduce the most general laws governing atmospheric circulation and diffusion. After having given a general table of the radioactive aerosols present the authors consider the validity and the precision of the measurement methods and the concentration of the aerosols at ground level and in the upper atmosphere, as well as their deposition on the ground. The existence is thus demonstrated of a tropospheric equatorial barrier and of discontinuous and seasonal aspects of stratosphere-troposphere transfers. The role is shown of precipitations and dry auto-filtration in the lower atmosphere cleaning processes. This work makes it possible to describe the general behaviour of dust from the stratosphere, and to improve the total radioactive contamination of the globe. (author) [French] L'objectif de ce travail consiste a examiner le comportement des aerosols radioactifs introduits dans l'atmosphere par les explosions nucleaires, pour en deduire les lois les plus generals de la circulation et diffusion atmospheriques. Apres avoir dresse un tableau d'ensemble des aerosols radioactifs presents, on examine la validite et la precision des methodes de mesure de leur concentration, au niveau du sol et en haute atmosphere, ainsi que de leur depot a la surface du sol. On met ainsi en evidence l'existence d'une barriere equatoriale tropospherique; l'aspect discontinu et saisonnier des transferts stratosphere-troposphere; le role des precipitations et de l'auto-filtration seche, dans les processus de nettoyage de la basse atmosphere. Ces etudes permettent de decrire le comportement general des poussieres d'origine stratospherique et d'ameliorer le bilan de la contamination radioactive du globe. (auteur)

  8. Study of the behaviour of artificial radioactive aerosols. Applications to some problems of atmospheric circulation (1963); Etude du comportement dcs aerosols radioactifs artificiels. Applications a quelques problemes de circulation atmospherique (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Lambert, G [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-11-15

    The aim of this work, consists in the examination of the behaviour of radioactive aerosols produced in the atmosphere by nuclear explosions, in order to deduce the most general laws governing atmospheric circulation and diffusion. After having given a general table of the radioactive aerosols present the authors consider the validity and the precision of the measurement methods and the concentration of the aerosols at ground level and in the upper atmosphere, as well as their deposition on the ground. The existence is thus demonstrated of a tropospheric equatorial barrier and of discontinuous and seasonal aspects of stratosphere-troposphere transfers. The role is shown of precipitations and dry auto-filtration in the lower atmosphere cleaning processes. This work makes it possible to describe the general behaviour of dust from the stratosphere, and to improve the total radioactive contamination of the globe. (author) [French] L'objectif de ce travail consiste a examiner le comportement des aerosols radioactifs introduits dans l'atmosphere par les explosions nucleaires, pour en deduire les lois les plus generals de la circulation et diffusion atmospheriques. Apres avoir dresse un tableau d'ensemble des aerosols radioactifs presents, on examine la validite et la precision des methodes de mesure de leur concentration, au niveau du sol et en haute atmosphere, ainsi que de leur depot a la surface du sol. On met ainsi en evidence l'existence d'une barriere equatoriale tropospherique; l'aspect discontinu et saisonnier des transferts stratosphere-troposphere; le role des precipitations et de l'auto-filtration seche, dans les processus de nettoyage de la basse atmosphere. Ces etudes permettent de decrire le comportement general des poussieres d'origine stratospherique et d'ameliorer le bilan de la contamination radioactive du globe. (auteur)

  9. Micro elements for interrogating magnetoelastic sensors

    KAUST Repository

    Liang, Cai

    2011-11-01

    This paper reports a new approach for interrogating a magnetoelastic sensor\\'s resonant frequency. Previously, the frequency of a magnetoelastic sensor was measured by using a large-scale solenoid coil of at least some millimeters both in diameter and length. Planar structures of straight-line and rectangular spiral coil are designed, fabricated and tested to interrogate the resonant frequency of a magnetoelastic sensor. A sensor of 4 mm length is measured to have a resonant frequency of 551 kHz in air. The ability to interrogate a magnetoelastic sensor with such microscale elements is a step towards the miniaturization of a magnetoelastic sensor system and integration of such a system in a microfluidics device. © 2011 IEEE.

  10. Advanced FBG sensing through rapid spectral interrogation

    Science.gov (United States)

    Kunzler, Wesley; Newman, Jason; Wilding, Daniel; Zhu, Zixu; Lowder, Tyson; Selfridge, Richard; Schultz, Stephen; Wirthlin, Michael

    2008-03-01

    A fiber Brag grating sensor interrogator has been developed which is capable of gathering vectors of information from individual fiber Bragg gratings by capturing the full optical spectrum 3 kHz. Using a field programmable gate array with high speed digital-to-analog converters and analog-to-digital components, plus a kilohertz rate MEMS optical filter, the optical spectrum can be scanned at rates in excess of 10 million nanometers per second, allowing sensor sampling rates of many kilohertz while maintaining the necessary resolution to understand sensor changes. The autonomous system design performs all necessary detection and processing of multiple sensors and allows spectral measurements to be exported as fast as Ethernet, USB, or RS232 devices can receive it through a memory mapped interface. The high speed - full spectrum - fiber Bragg grating sensor interrogator enables advanced interrogation of dynamic strain and temperature gradients along the length of a sensor, as well as the use of each sensor for multiple stimuli, such as in temperature compensation. Two examples are described, showing interrogation of rapid laser heating in an optical fiber, as well as complex strain effects in a beam that had an engineered defect.

  11. Interrogative Suggestibility in an Adolescent Forensic Occupation.

    Science.gov (United States)

    Richardson, G.; And Others

    1995-01-01

    Sixty-five juvenile offenders in residential care completed the Gudjonsson Suggestibility Scale, and their scores were matched for IQ and memory with those of 60 adult offenders. The juveniles gave in significantly more to interrogative pressure through negative feedback but were no more yielding to leading questions than adults. (JPS)

  12. Interrogative suggestibility and perceptual motor performance.

    Science.gov (United States)

    Gudjonsson, G H

    1984-04-01

    This study investigates the relationship between interrogative suggestibility, as measured by the Gudjonsson Suggestibility Scale, and Arrow-Dot scores. The tendency of subjects (25 men and 25 women, mean age 30.2 yr.) to alter their answers once interpersonal pressure had been applied correlated significantly with poor Arrow-Dot Ego functioning.

  13. Photon interrogation annual report for FY 1979

    International Nuclear Information System (INIS)

    Nieschmidt, E.B.; Johnson, L.O.; Lawrence, R.S.; Vegors, S.H. Jr.

    1980-03-01

    Summaries of experimental information and information from vendors is presented to show the adequacy of the photon interrogation technique for transuranic waste assay. An instrument system is described which has high immunity to gamma flash and has good high count rate capabilities. Comparison of the progress of the program with a schedule presented at its inception is presented

  14. Micro elements for interrogating magnetoelastic sensors

    KAUST Repository

    Liang, Cai; Gooneratne, Chinthaka Pasan; Kosel, Jü rgen; Mathison, Leslie C.; Chin, Bryan

    2011-01-01

    and length. Planar structures of straight-line and rectangular spiral coil are designed, fabricated and tested to interrogate the resonant frequency of a magnetoelastic sensor. A sensor of 4 mm length is measured to have a resonant frequency of 551 kHz in air

  15. Rheo: Japanese Sound Art Interrogating Digital Mediality

    DEFF Research Database (Denmark)

    Vandsø, Anette

    2014-01-01

    THe article asks in what way the Japanese sound artist Ryoichi Kurokawa's audiovisual installation Rheo 5 Horisonz (2010) is 'digital'. Using Professor Lars Elleströms concept of 'mediality, the main claim in this article is that Rheo no only uses digital tehcnology, but also interrogates digital...

  16. Adaptive interrogation for 3D-PIV

    International Nuclear Information System (INIS)

    Novara, Matteo; Scarano, Fulvio; Ianiro, Andrea

    2013-01-01

    A method to adapt the shape and orientation of interrogation volumes for 3D-PIV motion analysis is introduced, aimed to increase the local spatial resolution. The main application of this approach is the detailed analysis of complex 3D and vortex-dominated flows that exhibit high vorticity in confined regions like shear layers and vortex filaments. The adaptive criterion is based on the analysis of the components of the local velocity gradient tensor, which returns the level of anisotropy of velocity spatial fluctuations. The principle to increase the local spatial resolution is based on the deformation of spherical isotropic interrogation regions, obtained by means of Gaussian weighting, into ellipsoids, with free choice of the principal axes and their directions. The interrogation region is contracted in the direction of the maximum velocity variation and elongated in the minimum one in order to maintain a constant interrogation volume. The adaptivity technique for three-dimensional PIV data takes advantage of the 3D topology of the flow, allowing increasing the spatial resolution not only in the case of shear layers, but also for vortex filaments, which is not possible for two-dimensional measurement in the plane normal to the vortex axis. The definition of the ellipsoidal interrogation region semi-axes is based on the singular values and singular directions of the local velocity gradient tensor as obtained by the singular values decomposition technique (SVD). The working principle is verified making use of numerical simulations of a shear layer and of a vortex filament. The application of the technique to data from a Tomo-PIV experiment conducted on a round jet, shows that the resolution of the shear layer at the jet exit can be considerably improved and an increase of about 25% in the vorticity peak is attained when the adaptive approach is applied. On the other hand, the peak vorticity description in the core of vortex rings is only slightly improved with

  17. Notes on SAW Tag Interrogation Techniques

    Science.gov (United States)

    Barton, Richard J.

    2010-01-01

    We consider the problem of interrogating a single SAW RFID tag with a known ID and known range in the presence of multiple interfering tags under the following assumptions: (1) The RF propagation environment is well approximated as a simple delay channel with geometric power-decay constant alpha >/= 2. (2) The interfering tag IDs are unknown but well approximated as independent, identically distributed random samples from a probability distribution of tag ID waveforms with known second-order properties, and the tag of interest is drawn independently from the same distribution. (3) The ranges of the interfering tags are unknown but well approximated as independent, identically distributed realizations of a random variable rho with a known probability distribution f(sub rho) , and the tag ranges are independent of the tag ID waveforms. In particular, we model the tag waveforms as random impulse responses from a wide-sense-stationary, uncorrelated-scattering (WSSUS) fading channel with known bandwidth and scattering function. A brief discussion of the properties of such channels and the notation used to describe them in this document is given in the Appendix. Under these assumptions, we derive the expression for the output signal-to-noise ratio (SNR) for an arbitrary combination of transmitted interrogation signal and linear receiver filter. Based on this expression, we derive the optimal interrogator configuration (i.e., transmitted signal/receiver filter combination) in the two extreme noise/interference regimes, i.e., noise-limited and interference-limited, under the additional assumption that the coherence bandwidth of the tags is much smaller than the total tag bandwidth. Finally, we evaluate the performance of both optimal interrogators over a broad range of operating scenarios using both numerical simulation based on the assumed model and Monte Carlo simulation based on a small sample of measured tag waveforms. The performance evaluation results not only

  18. Nuclear materials identification by photon interrogation

    International Nuclear Information System (INIS)

    Pozzi, S.A.; Monville, M.; Padovani, E.

    2005-01-01

    We describe a preliminary modification to the Monte Carlo codes MCNP-X and MCNP-PoliMi that is aimed at simulating the neutron and photon field generated by interrogating fissile (and non-fissile) material with a high energy photon source. Photo-atomic and photo-nuclear collisions are modeled, with particular emphasis on the generation of secondary particles that are emitted as a result of these interactions. The simulations can be used to design and analyze measurements that are performed in a wide variety of scenarios. An application of the methodology to the interrogation of packages on a luggage belt conveyor is presented. Preliminary results show that it is possible to detect 5 Kg of highly enriched uranium in a package by measuring the correlation function between 2 detectors. This correlation function is based on the detection of prompt radiation from photonuclear events

  19. Natural syntax : English interrogative main clauses

    Directory of Open Access Journals (Sweden)

    Janez Oresnik

    2007-12-01

    Full Text Available Natural Syntax is a developing deductive theory, a branch of Naturalness Theory. The naturalnessjudgements are couched in naturalness scales, whichfollow from the basic parameters (or «axioms» listed at the beginning of the paper. The predictions of the theory are calculated in deductions, whose chief components are apair of naturalness scales and the rules governing the alignment of corresponding naturalness values. Parallel and chiastic alignments are distinguished, in complementary distribution. Chiastic alignment is mandatory in deductions limited to unnatural environments. The paper deals with English interrogative main clauses. Within these, only the interrogatives containing wh-words exclusively insitu constitute an extremely unnatural environment and require chiastic alignment. Otherwiseparallel alignment is used. Earlier publications on Natural Syntax: Kavcic 2005a,b, Oresnik 1999, 2000a,b, 200la-f   2002, 2003a-c, 2002/03, 2004. This list cites only works written in English.

  20. Wirelessly Interrogated Wear or Temperature Sensors

    Science.gov (United States)

    Woodard, Stanley E.; Taylor, Bryant D.

    2010-01-01

    Sensors for monitoring surface wear and/or temperature without need for wire connections have been developed. Excitation and interrogation of these sensors are accomplished by means of a magnetic-field-response recorder. In a sensor of the present type as in the previously reported ones, the capacitance and, thus, the resonance frequency, varies as a known function of the quantity of interest that one seeks to determine. Hence, the resonance frequency is measured and used to calculate the quantity of interest.

  1. Some examples of the use of radioactive tracers in pharmacodynamic; Quelques exemples de l'emploi des traceurs radioactifs en pharmacodynamie

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, Y [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    The study of absorption, of distribution in the organism and of the elimination of a medicament has been greatly facilitated by the development of nuclear applications. In effect, the introduction into the molecule of one or several radioactive atoms makes it possible to follow the path and destination of minute quantities of the drug and to thus carry out analyses on the animal within limits of posology close to those of therapeutics. However the qualitative or quantitative methods used have certain limits and they must be compared amongst themselves and with others. Some examples will show : - the importance of the way of administering the drug on the changes in the distribution; - the quite relative selectivity of this latter; - and lastly, the different process involved in the elimination mechanisms. (author) [French] L'etude de l'absorption, de la repartition dans l'organisme et de l'elimination d'un medicament s'est trouvee grandement facilitee par le developpement des applications nucleaires. En effet, l'introduction dans une molecule d'un ou plusieurs atomes radioactifs permet de suivre le sort de quantites infimes de la drogue et de ce fait d'en effectuer l'analyse chez l'animal dans des limites de posologie se rapprochant de celles de la therapeutique. Cependant les methodes employees, qualitatives ou quantitatives, presentent des limites et doivent etre confrontees entre elles et avec d'autres methodes. Quelques exemples mettront en evidence: - l'importance du mode d'administration sur l'evolution de la repartition, - l'electivite toute relative de cette derniere, - et enfin, les modalites diverses des mecanismes d'elimination. (auteur)

  2. Results of concentration measurements of artificial radioactive aerosols in the lower atmosphere; Resultats des mesures de concentration, dans la basse atmosphere, des aerosols radioactifs artificiels

    Energy Technology Data Exchange (ETDEWEB)

    Ardouin, B; Jehanno, C; Labeyrie, J; Lambert, G; Tanaevsky, O; Vassy, E [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-07-01

    This report gives the results of the measurements of artificial gross-{beta}-radioactivity in aerosols in the lower atmosphere; these measurements have been made by the Electronic Physics Service of the Electronic Department, and by the Atmospheric Physics Laboratory of the Paris Science Faculty. The measurements were begun in September 1956 and were continued in an increasing number of stations both in France and in the rest of the world. The present report deals with the period up to the end of august 1961, that is up to the end of the nuclear moratorium. After recalling the constitution and the properties of radioactive aerosols present in the atmosphere, the authors describe the measurement methods, estimate their accuracy and discuss various aspects of the results. (authors) [French] Ce rapport contient les resultats des mesures de radioactivite {beta} globale d'origine artificielle des aerosols dans la basse atmosphere, effectuees conjointement par le Service d'Electronique Physique du Departement d'Electronique et le Laboratoire de Physique de l'Atmosphere de la Faculte des Sciences de Paris. Les mesures ont commence en septembre 1956 et ont ete poursuivies dans un nombre croissant de stations, tant en France que dans le reste du monde. Le present rapport s'arrete a la fin aout 1961, c'est-a-dire au moment de la reprise des essais nucleaires. Apres avoir rappele la constitution et les proprietes des aerosols radioactifs presents dans l'atmosphere, les auteurs indiquent les methodes de mesure utilisees, evaluent leur precision et discutent les differents aspects des resultats de leurs mesures. (auteurs)

  3. Revenge versus rapport: Interrogation, terrorism, and torture.

    Science.gov (United States)

    Alison, Laurence; Alison, Emily

    2017-04-01

    This review begins with the historical context of harsh interrogation methods that have been used repeatedly since the Second World War. This is despite the legal, ethical and moral sanctions against them and the lack of evidence for their efficacy. Revenge-motivated interrogations (Carlsmith & Sood, 2009) regularly occur in high conflict, high uncertainty situations and where there is dehumanization of the enemy. These methods are diametrically opposed to the humanization process required for adopting rapport-based methods-for which there is an increasing corpus of studies evidencing their efficacy. We review this emerging field of study and show how rapport-based methods rely on building alliances and involve a specific set of interpersonal skills on the part of the interrogator. We conclude with 2 key propositions: (a) for psychologists to firmly maintain the Hippocratic Oath of "first do no harm," irrespective of perceived threat and uncertainty, and (b) for wider recognition of the empirical evidence that rapport-based approaches work and revenge tactics do not. Proposition (a) is directly in line with fundamental ethical principles of practice for anyone in a caring profession. Proposition (b) is based on the requirement for psychology to protect and promote human welfare and to base conclusions on objective evidence. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  4. Quantum prisoners' dilemma under enhanced interrogation

    Science.gov (United States)

    Siopsis, George; Balu, Radhakrishnan; Solmeyer, Neal

    2018-06-01

    In the quantum version of prisoners' dilemma, each prisoner is equipped with a single qubit that the interrogator can entangle. We enlarge the available Hilbert space by introducing a third qubit that the interrogator can entangle with the other two. We discuss an enhanced interrogation technique based on tripartite entanglement and analyze Nash equilibria. We show that for tripartite entanglement approaching a W-state, we calculate the Nash equilibria numerically and show that they coincide with the Pareto-optimal choice where both prisoners cooperate. Upon continuous variation between a W-state and a pure bipartite entangled state, the game is shown to have a surprisingly rich structure. The role of bipartite and tripartite entanglement is explored to explain that structure. As an application, we consider an evolutionary game based on our quantum game with a network of agents on a square lattice with periodic boundary conditions and show that the strategy corresponding to Nash equilibrium completely dominates without placing any restrictions on the initial set of strategies.

  5. suPAR

    DEFF Research Database (Denmark)

    Hodges, Gethin W; Bang, Casper N; Wachtell, Kristian

    2015-01-01

    The fundamental role of inflammation in cardiovascular disease (CVD) has prompted interest in numerous biomarkers that detect subclinical levels of inflammation. Soluble urokinase plasminogen activator receptor (suPAR) is a novel biomarker that correlates significantly with cardiovascular events ...... comprehensive review of suPAR in CVD and explore its function and usefulness in predicting cardiovascular events....

  6. Experiment of decontamination of radioactive liquid by a biological method; Experience de decontamination de liquides radioactifs far voie biologique

    Energy Technology Data Exchange (ETDEWEB)

    Wormser, G.

    1962-07-01

    The author reports experiments of treatment of radioactive liquid effluents by percolation on a bacterial bed like the one used for the treatment of sewer wastewaters. He also reports results obtained in other countries in terms of reduction of effluent radioactivity for various radioactive ions. The installation is described and results are presented in terms of variation of contamination of an effluent with respect to its recycling on a bacterial bed [French] Dans le monde entier, on se preoccupe des moyens de decontamination pour des liquides radioactifs. Les experiences de l'auteur ont confirme qu'un lit bacterien neuf peut donner de bons resultats: il est a noter que ce procede biologique se montre selectif a l'egard des divers ions radioactifs. (auteur)

  7. Par Pond water balance

    International Nuclear Information System (INIS)

    Hiergesell, R.A.; Dixon, K.L.

    1996-06-01

    A water budget for the Par Pond hydrologic system was established in order to estimate the rate of groundwater influx to Par Pond. This estimate will be used in modeling exercises to predict Par Pond reservoir elevation and spillway discharge in the scenario where Savannah River water is no longer pumped and discharged into Par Pond. The principal of conservation of mass was used to develop the water budget, where water inflow was set equal to water outflow. Components of the water budget were identified, and the flux associated with each was determined. The water budget was considered balanced when inflow and outflow summed to zero. The results of this study suggest that Par Pond gains water from the groundwater system in the upper reaches of the reservoir, but looses water to the groundwater system near the dam. The rate of flux of groundwater from the water table aquifer into Par Pond was determined to be 13 cfs. The rate of flux from Par Pond to the water table aquifer near the dam was determined to be 7 cfs

  8. FooPar

    DEFF Research Database (Denmark)

    Hargreaves, F. P.; Merkle, D.

    2013-01-01

    We present FooPar, an extension for highly efficient Parallel Computing in the multi-paradigm programming language Scala. Scala offers concise and clean syntax and integrates functional programming features. Our framework FooPar combines these features with parallel computing techniques. Foo......, results based on a empirical analysis on two supercomputers are given. We achieve close-to-optimal performance wrt. theoretical peak performance. Based on this result we conclude that FooPar allows programmers to fully access Scalas design features without suffering from performance drops when compared...

  9. Photon interrogation for bulk measurement of transuranic materials

    International Nuclear Information System (INIS)

    Nieschmidt, E.B.

    1981-01-01

    Investigation and assay of high atomic number materials may be accomplished in near real-time through use of photon interrogation. Photon interrogation, as used here, involves the use of high-energy photons to induce fission and then detect neutrons associated with the fission. This technique has the advantage that the interrogating particle and the detected particle are different. The discussion here will include: (1) neutron production; (2) photon production; (3) neutron counting; (4) sensitivity; and (5) problems associated with large containers. In summary, the attributes and limitations of photon interrogation can be stated as: near real-time accountability; interrogating particle different than detected particle; ability to count prompt or delayed neutrons depending on matrix; radiography or therapy accelerators available; cannot distinguish between fission and fertile material; and interrogated material must be well characterized to obtain safeguards quality results

  10. Some Questions on the Fixation of Radioisotopes in Connexion with the Problem of their Safe Burial; Quelques Aspects de la Fixation des Isotopes Radioactifs en Rapport avec le Probleme de leur Elimination dans le Sol; 041d 0414 ; Algunos Aspectos de la Fijacion de los Isotopos Radiactivos en Relacion con los Problemas de su Evacuacion sin Riesgos en el Suelo

    Energy Technology Data Exchange (ETDEWEB)

    Zimakov, P. V.; Kulichenko, V. V.

    1960-07-01

    The results given in this paper are based on the fact that the best way of burying fission products is to incorporate them in vitrified fused blocks containing these fission products. The physico-chemical bases of the transformation of liquid waste into solid blocks are shown. The thermogram of this process is presented and the analysis of its characteristics given. The conditions of fusion of the vitrified mass, in particular those contributing to the fixation of radioactive aerosols, are shown. Some results of studies on the chemical state of radioactive fission products in the solid mass in connexion with the leaching of their radioactivity are given. In conclusion, the results of calculations of the temperatures up to which the radioactive blocks may be heated according to their characteristics are presented. (author) [French] Le present memoire est base sur l'hypothese que le meilleur procede d'elimination des dechets radioactifs dans le sous:sol consiste a les enfouir sous forme de blocs coules dans lesquels ils seraient intimement meles a du verre. Les auteurs decrivent les phenomenes physico-chimiques qui permettent la transformation des dechets radioactifs liquides en blocs solides. Ils donnent le thermogramme de ce processus et examinent certaines de ses particularites. Ils exposent en outre les conditions de coulage de la masse de verre, notamment celles qui facilitent la formation d'aerosols radioactifs. Les auteurs donnent quelques resultats des etudes effectuees sur l'etat chimique des elements radioactifs au sein de la masse solide, dans la mesure ou ces resultats touchent aux problemes que pose la fuite de la radioactivite due au 'lessivage' du bloc par l'eau. En conclusion, les auteurs indiquent les resultats du calcul des temperatures maxima auxquelles on peut porter les blocs radioactifs compte tenu de leurs caracteristiques. (author) [Spanish] Los autores de la memoria parten del supuesto de que la mejor manera de evacuar en el suelo los

  11. SIMULATION OF CARGO CONTAINER INTERROGATION BY D-D NEUTRONS

    International Nuclear Information System (INIS)

    Lou, Tak Pui; Antolak, Arlyn

    2007-01-01

    High fidelity, three-dimensional computer models based on a CAD drawing of an intermodal cargo container, representative payload objects, and detector array panels were developed to simulate the underlying physical events taking place during active interrogation. These computer models are used to assess the performance of interrogation systems with different sources and detection schemes. In this presentation, we will show that the use oversimplified models, such as analyzing homogenized payloads only, can lead to errors in determining viable approaches for interrogation

  12. "Enhanced" interrogation of detainees: do psychologists and psychiatrists participate?

    OpenAIRE

    Halpern, Abraham L; Halpern, John H; Doherty, Sean B

    2008-01-01

    Abstract After revelations of participation by psychiatrists and psychologists in interrogation of prisoners at Guantánamo Bay and Central Intelligence Agency secret detention centers, the American Psychiatric Association and the American Psychological Association adopted Position Statements absolutely prohibiting their members from participating in torture under any and all circumstances, and, to a limited degree, forbidding involvement in interrogations. Some interrogations utilize very agg...

  13. The use of an experimental device for the determination of the concentration of artificial radioactive aerosols at high altitudes; Utilisation d'un missile experimental pour l'evaluation des concentrations en aerosols radioactifs artificiels en haute altitude

    Energy Technology Data Exchange (ETDEWEB)

    Boclet, D; Jehanno, C; Labeyrie, J [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires; Le Boiteux, H [Office National d' Etudes et de Recherches Aeronautique, 92 - Chatillon sous Bagneux (France)

    1960-07-01

    By means of measurements with a Geiger counter on january, the 27{sup th}, in 1959 at an altitude reaching 65 km approximately, and following comparison with similar measurements made by Gangnes, Jenkins and Van Allen in 1949 at the same geomagnetic latitude (41 deg. North), it is concluded that radioactive aerosols above Southern France tropopause had a concentration less than 100.10{sup -12} curies/m{sup 3} at that time. The missile used for this purpose and its performance are quickly described in this paper. (author) [French] Au moyen de mesures faites au compteur Geiger le 27 janvier 1959 jusqu'au environ de 65 km et apres comparaison avec des mesures analogues faites en 1949 par Gangnes, Jenkins et Van Allen a la meme altitude geomagnetique (41deg. N), on conclut que les aerosols radioactifs au-dessus de la tropopause de la France meridionale avaient a cette epoque une concentration inferieure a 100.10{sup -12} curies/m{sup 3}. Une rapide description du missile utilise et de ses performances complete cette communication. (auteur)

  14. Count rate balance method of measuring sediment transport of sand beds by radioactive tracers; Methode du bilan des taux de comptage d'indicateurs radioactifs pour la determination du debit de charriage des lits sableux

    Energy Technology Data Exchange (ETDEWEB)

    Sauzay, G [Commissariat a l' Energie Atomique, 91 - Saclay (France). Centre d' Etudes Nucleaires

    1967-11-01

    Radioactive tracers are applied to the direct measurement of the sediment transport rate of sand beds. The theoretical measurement formula is derived: the variation of the count rate balance is inverse of that of the transport thickness. Simultaneously the representativeness of the tracer is critically studied. The minimum quantity of tracer which has to be injected in order to obtain a correct statistical definition of count rate given by a low number of grains 'seen' by the detector is then studied. A field experiment was made and has let to study the technological conditions for applying this method: only the treatment of results is new, the experiment itself is carried out with conventional techniques applied with great care. (author) [French] Les indicateurs radioactifs sont appliques a la mesure directe du debit de charriage des lits sableux. On etablit la formule theorique de mesure: le bilan des taux de comptage varie en sens inverse de l'epaisseur de charriage. Parallelement on fait une etude critique de la representativite de l'indicateur, puis on determine la quantite minimale de traceur qu'il faut immerger pour que les taux de comptage fournis pour un faible nombre de grains 'vus' par le detecteur aient une definition statistique correcte. Une experience de terrain a permis d'etudier les conditions technologiques de cette methode: seul le depouillement des resultats est nouveau. L'experimentation in-situ se fait suivant les procedes classiques avec un tres grand soin. (auteur)

  15. Caesium absorption by barley - influence of its retention by the soil - competitive action of potassium; Absorption du cesium par l'orge - influence de sa retention dans le sol - action competitive du potassium

    Energy Technology Data Exchange (ETDEWEB)

    Ferron-Trosseau, F. [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1964-06-01

    plants such as rice and cress growing on flooded soils. Radio-active caesium however incorporated without carrier into a soil of medium-exchange capacity (of about 150 milli-equivalents per kilo) presents relatively little danger because of the close interdependence of the radioactive caesium take-up from the soil by the plants and its retention by the soil. Our research has made it possible furthermore to examine the value of various partial decontamination methods for soils proposed by certain atomic scientists: just as isotopic dilution appears totally inadequate for this purpose, so does it seems that the addition of potassium salts in amounts greater than nutritive optimum is incapable of reducing the absorption of radioactive caesium by the plant. (author) [French] Nous avons recherche, dans divers milieux de culture, comment l'absorption du cesium par l'orge varie avec sa concentration et comment cette absorption peut etre concurrencee par un cation alcalin voisin,le potassium. En outre, nous avons considere la distribution du cesium dans le sol - notamment du cesium radioactif - entre terre et solution, en fonction du taux de cesium. De notre etude ressort une nette opposition entre le comportement de l'orge vis a vis du cesium d'une solution nutritive et vis a vis du cesium d'un sol: sur solution nutritive, la fraction du cesium (radioactif et stable) absorbee par l'orge demeure pratiquement constante en presence de proportions croissantes (relativement petites) de cesium stable; sur sol, la fraction du cesium radioactif absorbee par l'orge a augmente en meme temps que le taux (relativement petit) de cesium stable du sol, en relation avec une selectivite rapidement decroissante du sol pour Cs. La difference entre ces resultats est donc expliquee par une tres forte selectivite du sol illitique experimente pour Cs{sup +} tant que la proportion da cesium reste tres petite, de l'ordre de celle de la plupart des sols naturels

  16. Caesium absorption by barley - influence of its retention by the soil - competitive action of potassium; Absorption du cesium par l'orge - influence de sa retention dans le sol - action competitive du potassium

    Energy Technology Data Exchange (ETDEWEB)

    Ferron-Trosseau, F [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1964-06-01

    as rice and cress growing on flooded soils. Radio-active caesium however incorporated without carrier into a soil of medium-exchange capacity (of about 150 milli-equivalents per kilo) presents relatively little danger because of the close interdependence of the radioactive caesium take-up from the soil by the plants and its retention by the soil. Our research has made it possible furthermore to examine the value of various partial decontamination methods for soils proposed by certain atomic scientists: just as isotopic dilution appears totally inadequate for this purpose, so does it seems that the addition of potassium salts in amounts greater than nutritive optimum is incapable of reducing the absorption of radioactive caesium by the plant. (author) [French] Nous avons recherche, dans divers milieux de culture, comment l'absorption du cesium par l'orge varie avec sa concentration et comment cette absorption peut etre concurrencee par un cation alcalin voisin,le potassium. En outre, nous avons considere la distribution du cesium dans le sol - notamment du cesium radioactif - entre terre et solution, en fonction du taux de cesium. De notre etude ressort une nette opposition entre le comportement de l'orge vis a vis du cesium d'une solution nutritive et vis a vis du cesium d'un sol: sur solution nutritive, la fraction du cesium (radioactif et stable) absorbee par l'orge demeure pratiquement constante en presence de proportions croissantes (relativement petites) de cesium stable; sur sol, la fraction du cesium radioactif absorbee par l'orge a augmente en meme temps que le taux (relativement petit) de cesium stable du sol, en relation avec une selectivite rapidement decroissante du sol pour Cs. La difference entre ces resultats est donc expliquee par une tres forte selectivite du sol illitique experimente pour Cs{sup +} tant que la proportion da cesium reste tres petite, de l'ordre de celle de la plupart des sols naturels. Par ailleurs, l'ion K{sup +} n'a concurrence l

  17. The use radioactive tracers in the study of solid transport in water streams; Emploi de traceurs radioactifs pour l'etude du transport solide dans les cours d'eau

    Energy Technology Data Exchange (ETDEWEB)

    Courtois, G [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires; Jaffry, P; Heuzel, M [Laboratoire National d' Hydraulique de Chatou, 78 (France)

    1960-07-01

    The Laboratoire National d'Hydraulique which has been studying, during the last few years in conjunction with the Centre d'Etudes Nucleaires at Saclay, the development of apparatus and of methods of investigation of sediment transport by radioactive tracer techniques, is at the moment trying to perfect a genuinely quantitative method of investigation. Two experiments have recently been carried out in rivers, the first designed to investigate the transport of pebbles in the river Rhone, the other to investigate the movement of sands in the Niger. This second experiment has been supported by parallel experiments carried out on a reduced scale model of the Niger built at the laboratories of Chatou: in this experiment are used the radiation from {sup 56}Mn and {sup 24}Na obtained by direct activation of the crushed apricot store which represents, in the scale model, the natural sediment on the bed of the Niger. The combined efforts of the laboratories of Chatou and of the Centre d'Etudes Nucleaires at Saclay are at the moment directed to the application of radioactive tracers to studies on the scale models with the double aim: a) of having a single investigational method for the actual experiment and for the model making it possible to control the accuracy of the model in the preliminary stage of calibrating this model; b) of making the most of the possibilities of observation and of direct measurement offered by the scale models for studying the possibility of improving the tracer method, in particular with respect to the collecting of quantitative data. (author) [French] La Laboratoire National d'Hydraulique qui, depuis quelques annees a developpe, en collaboration avec le Centre d'Etudes Nucleaires de Saclay, les appareillages et les techniques d'etudes des mouvements de sediments par la methode des traceurs radioactifs, s'efforce actuellement de mettre au point un moyen d'investigation veritablement quantitatif. Deux experiences ont ete effectuees recemment en

  18. Photon interrogation annual report for FY-1980

    International Nuclear Information System (INIS)

    Nieschmidt, E.B.; Tsang, F.Y.; Lawrence, R.S.; Vegors, S.H. Jr.

    1980-12-01

    The Photon Interrogation Technique is being developed for the assay of transuranic materials. A description of source and detector geometry, die-away times and photon flux measurements is given. Considerable effort during FY-1980 was devoted to collimator construction and shielding materials and configurations. Boric acid was found to be a very efficient shielding material for this application. Descriptions and results of these efforts are presented. Results of photon flux determinations, system response to source position and their effects on accuracy are discussed. Changes in the detector system produced a considerable efficiency increase and instrumentation changes brought improved performance. The instrument system with additions can obtain neutron spectral information. A schedule for further development of the system is presented

  19. Some Semantic Properties of Romanian Interrogatives: "Care" and "Cine."

    Science.gov (United States)

    Vasiliu, E.

    The aim of this paper is to account for some semantic properties of Romanian interrogatives "ce" and "cine" by establishing some definite correlations between various contextual restrictions governing the use of these interrogative particles and the "meaning" which might be assigned to each of these particles in any…

  20. Optimization of periodical interrogation of transducers of radioisotope measuring systems

    International Nuclear Information System (INIS)

    Ivashchenko, A.S.; Kaznakov, V.P.; Korolev, V.M.

    1978-01-01

    Certain methods are examined of optimizing periodic interrogation of sensors connected in a definite sequence to device for data processing in a system for controlling production processes. It is shown that in designing multiinput radioisotope measurement systems with a centralized data processing, the choice of the method of organizing periodic interrogation should be made with account for the conditions existing in each specific case

  1. Laser interrogation of latent vehicle registration number

    Energy Technology Data Exchange (ETDEWEB)

    Russo, R.E. [Lawrence Berkeley Lab., CA (United States). Energy and Environment Div.]|[Lawrence Livermore National Lab., CA (United States). Forensic Science Center; Pelkey, G.E. [City of Livermore Police Dept., CA (United States); Grant, P.; Whipple, R.E.; Andresen, B.D. [Lawrence Livermore National Lab., CA (United States). Forensic Science Center

    1994-09-01

    A recent investigation involved automobile registration numbers as important evidentiary specimens. In California, as in most states, small, thin metallic decals are issued to owners of vehicles each year as the registration is renewed. The decals are applied directly to the license plate of the vehicle and typically on top of the previous year`s expired decal. To afford some degree of security, the individual registration decals have been designed to tear easily; they cannot be separated from each other, but can be carefully removed intact from the metal license plate by using a razor blade. In September 1993, the City of Livermore Police Department obtained a blue 1993 California decal that had been placed over an orange 1992 decal. The two decals were being investigated as possible evidence in a case involving vehicle registration fraud. To confirm the suspicion and implicate a suspect, the department needed to known the registration number on the bottom (completely covered) 1992 decal. The authors attempted to use intense and directed light to interrogate the colored stickers. Optical illumination using a filtered white-light source partially identified the latent number. However, the most successful technique used a tunable dye laser pumped by a pulsed Nd:YAG laser. By selectively tuning the wavelength and intensity of the dye laser, backlit illumination of the decals permitted visualization of the underlying registration number through the surface of the top sticker. With optimally-tuned wavelength and intensity, 100% accuracy was obtained in identifying the sequence of latent characters. The advantage of optical techniques is their completely nondestructive nature, thus preserving the evidence for further interrogation or courtroom presentation.

  2. Decontamination of lead by fusion (1962); Decontamination du plomb par fusion (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Boutot, P; Giachetto, L; Capitaine, A [Commissariat a l' Energie Atomique, Centre de Production de Plutonium, Marcoule (France). Centre d' Etudes Nucleaires

    1962-07-01

    Various attempts to decontaminate using mechanical and chemical methods having given questionable results, a fusion method has been developed. The apparatus consists of a propane-heated oven fitted with a steel crucible of 1 400 kg capacity, with two ventilation systems, and with a vacuum gauge for preventing the diffusion of toxic gases. There are three operational controls : 1. On the samples taken before during and after the operation, 2. On the plugs taken from the ingots, 3. On the ingot itself. The continuous sanitary control is done by a radioactive aerosol recorder and by periodic sampling. This decontamination process will be improved, especially as far as the productivity and the safety precautions are concerned. (authors) [French] Divers essais de decontamination par voies mecaniques et chimiques ayant donne des resultats discutables, un procede par fusion a ete mis au point. L'appareil se compose d'un four, chauffe au propane, muni d'un creuset en acier d'une capacite de 1 400 kg, de deux systemes de ventilation et d'un deprimometre afin d'eviter la diffusion de vapeurs nocives. Trois controles d'activite sont effectues: 1. sur des echantillons preleves avant, pendant et apres l'operation, 2. sur des carottages realises sur les lingots, 3. sur le lingot lui-meme. Le controle sanitaire permanent est assure par un enregistreur d'aerosols radioactifs et par des prelevements periodiques. Ce procede de decontamination doit encore etre ameliore, principalement en ce qui concerne la productivite et la securite. (auteurs)

  3. L'analyse par activation de neutrons de réacteur

    Science.gov (United States)

    Meyer, G.

    2003-02-01

    Quand les neutrons traversent la matière, certains sont transmis sans interaction, les autres interagissent avec le milieu traversé par diffusion et par absorption. Ce phénomène d'absorption est utilisé pour se protéger des neutrons, mais aussi pour les détecter; il peut également être utilisé pour identifier les noyaux “absorbants" et ainsi analyser le milieu traversé. En effet par différentes réactions nucléaires (n,γ), (n,p), (n,α), (n,fission), on obtient des noyaux résiduels qui sont souvent radioactifs; on dit que l'échantillon est “activé". Si l'on connaît le rendement d'activation et donc le pourcentage de noyaux ainsi “transmutés", les mesures de radioactivité induite vont permettre de déterminer la composition de l'échantillon irradié. Cette méthode dite d'analyse par activation neutronique est pratiquée depuis la découverte du neutron. Elle a permis grâce à sa sélectivité et à sa sensibilité d'avoir accès au domaine des traces et des ultra-traces dans des champs d'application très divers comme la métallurgie, l'archéologie, la biologie, la géochimie etc...

  4. Technical and Economic Problems Associated with the Development of Methods of Processing and Using Radioactive Waste; Problemes techniques et economiques lies au developpement des methodes de traitement et d'utilisation des dechets radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    Thiriet, L; Sauteron, J; Oger, C [Commissariat a l' Energie Atomique, Fontenay-Aux-Roses (France). Centre d' Etudes Nucleaires

    1968-07-01

    The paper briefly reviews the various techniques used in processing the radioactive wastes which unavoidably result from the generation of electric power from nuclear sources. The paper goes on to define the relative importance, in nuclear fuel cycles, of the problem raised by these wastes. Emphasis is placed on the economic influence of management policies on the cost of power generation, and hence on the relative position of nuclear energy. A substantial percentage of these wastes can be economically utilized. Attention is drawn to the major technical and economic features of the industry which will come into being as a result of this utilization. The major uses anticipated are discussed: radiation sources, heat sources, auxiliary power generation. The paper concludes that satisfactory solutions have already been found to these problems, and describes possible improvements. (author) [French] La communication rappelle d'abord succinctement les differentes techniques de traitement des dechets radioactifs resultant necessairement de la production d'electricite d'origine nucleaire. On situe ensuite l'importance du probleme pose par ces residus dans le cycle du combustible nucleaire. On fait ressortir l'influence economique du choix des methodes de gestion sur le cout de production de l'energie, et par consequent sur la place devolue a l'energie nucleaire. Une part importante de ces dechets peut faire l'objet d'une utilisation rentable de l'industrie qui naitra de cette utilisation. Les principales applications envisagees sont evoquees: sources d'irradiation, sources chauffantes, generateurs auxiliaires d'energie. On conclut que d'ores et deja des solutions satisfaisantes ont ete apportees a ces problemes, et l'on decrit les perspectives d'amelioration concevables. (auteur)

  5. It's quicker "Par Avignon"!

    CERN Multimedia

    2005-01-01

    For a few years, the CERN Library has been receiving books from the University of Hanover sent via Avignon, at least that's what it says on the envelope. Such a detour would mean that parcels were travelling 720 km more than the distance separating Geneva and Hanover, which would be a very strange state of affairs. The explanation lies in a spelling mistake. The sender has been stamping parcels with a stamp that says "Par Avignon prioritaire" (first-class via Avignon) instead of "Par Avion prioritaire" (First Class Air Mail), a source of much amusement to the librarians!

  6. 76 FR 44282 - Defense Federal Acquisition Regulation Supplement; Prohibition on Interrogation of Detainees by...

    Science.gov (United States)

    2011-07-25

    ...-AG88 Defense Federal Acquisition Regulation Supplement; Prohibition on Interrogation of Detainees by... prescribes policies prohibiting interrogation of detainees by contractor personnel, as required by section... ancillary positions, including as trainers of, and advisors to, interrogations, if the contractor personnel...

  7. Treatment and final conditioning of solid radioactive wastes; Traitement et conditionnement definitif des dechets radioactifs solides

    Energy Technology Data Exchange (ETDEWEB)

    Cerre, J [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    The storage of solid radioactive wastes on a site is so cumbersome and dangerous that we have developed a method of treatment and conditioning by means of which the volume of waste is considerably reduced and very long-lasting shielding can be provided. This paper describes the techniques adopted at Saclay, where the wastes are sheared, compressed and enveloped in concrete of variable thickness. The main part of the report is devoted to a description of the corresponding remote handling installation. (author) [French] L'encombrement et le danger que presentent sur un site le stockage de dechets radioactifs solides nous ont amenes a etudier un mode de traitement et de conditionnement permettant une sensible reduction du volume des dechets et une protection de tres longue duree. La presente communication expose les techniques adoptees a Saclay ou les dechets sont cisailles, comprimes et enrobes dans du beton d'epaisseur variable. La description de l'installation telecommandee correspondante fait l'objet principal de cette communication. (auteur)

  8. Determination of radioactive risks connected with the working of a nuclear plant; Evaluation des risques radioactifs lies au fonctionnement d'une installation nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Lavie, J M; Doury, A [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    Numerous problems which are posed by the evaluation of the radioactive risks linked to the working of a nuclear plant are new problems which have not yet been satisfactorily solved. In these conditions this study must be considered only as a preliminary approach whose essential aims are the following: - development and synthesis of the existing data; - rapid determination of conservative and usable orders of greatness for the security factors, both for normal working and in the case of an accident. The most probable typical accidents are reviewed together with the nature of the resulting risks and the principal factors on which these risks depend. Among these factors, one of the most important is atmospheric diffusion which is studied in some detail using the analytic model due to Sutton. A logical graphical presentation increasing the flexibility in the use of the results and presents the responsible authorities with a flexible, practical and rapid means of evaluating the risks involved starting from a sufficiently general system of initial and simultaneously valid conditions (types of accident, atmospheric conditions). (author) [French] De nombreux problemes souleves par l'evaluation des risques radioactifs lies au fonctionnement d'une installation nucleaire sont des problemes nouveaux qui n'ont pas encore recu de solution satisfaisante. Dans ces conditions cette etude ne doit etre consideree que comme une premiere approche dont les objectifs essentiels sont les suivants: - mise au point et synthese de donnees existantes; - determination rapide d'ordres de grandeur conservatifs et utilisables de valeurs de securite, tant en fonctionnement normal qu'en cas d'accident. Les accidents types les plus probables sont passes en revue ainsi que la nature des risques qui en decoulent et les principaux facteurs dont dependent ces risques. Parmi ces facteurs, l'un des plus importants est la diffusion atmospherique qui fait l'objet d'une etude particuliere a l'aide du modele

  9. Safety and efficiency of emergency department interrogation of cardiac devices.

    Science.gov (United States)

    Neuenschwander, James F; Peacock, W Frank; Migeed, Madgy; Hunter, Sara A; Daughtery, John C; McCleese, Ian C; Hiestand, Brian C

    2016-12-01

    Patients with implanted cardiac devices may wait extended periods for interrogation in emergency departments (EDs). Our purpose was to determine if device interrogation could be done safely and faster by ED staff. Prospective randomized, standard therapy controlled, trial of ED staff device interrogation vs. standard process (SP), with 30-day follow-up. Eligibility criteria: ED presentation with a self-report of a potential device related complaint, with signed informed consent. SP interrogation was by company representative or hospital employee. Of 60 patients, 42 (70%) were male, all were white, with a median (interquartile range) age of 71 (64 to 82) years. No patient was lost to follow up. Of all patients, 32 (53%) were enrolled during business hours. The overall median (interquartile range) ED vs. SP time to interrogation was 98.5 (40 to 260) vs. 166.5 (64 to 412) minutes (P=0.013). While ED and SP interrogation times were similar during business hours, 102 (59 to 138) vs. 105 (64 to 172) minutes (P=0.62), ED interrogation times were shorter vs. SP during non-business hours; 97 (60 to 126) vs. 225 (144 to 412) minutes, P=0.002, respectively. There was no difference in ED length of stay between the ED and SP interrogation, 249 (153 to 390) vs. 246 (143 to 333) minutes (P=0.71), regardless of time of presentation. No patient in any cohort suffered an unplanned medical contact or post-discharge adverse device related event. ED staff cardiac device interrogations are faster, and with similar 30-day outcomes, as compared to SP.

  10. An adaptive sampling and windowing interrogation method in PIV

    Science.gov (United States)

    Theunissen, R.; Scarano, F.; Riethmuller, M. L.

    2007-01-01

    This study proposes a cross-correlation based PIV image interrogation algorithm that adapts the number of interrogation windows and their size to the image properties and to the flow conditions. The proposed methodology releases the constraint of uniform sampling rate (Cartesian mesh) and spatial resolution (uniform window size) commonly adopted in PIV interrogation. Especially in non-optimal experimental conditions where the flow seeding is inhomogeneous, this leads either to loss of robustness (too few particles per window) or measurement precision (too large or coarsely spaced interrogation windows). Two criteria are investigated, namely adaptation to the local signal content in the image and adaptation to local flow conditions. The implementation of the adaptive criteria within a recursive interrogation method is described. The location and size of the interrogation windows are locally adapted to the image signal (i.e., seeding density). Also the local window spacing (commonly set by the overlap factor) is put in relation with the spatial variation of the velocity field. The viability of the method is illustrated over two experimental cases where the limitation of a uniform interrogation approach appears clearly: a shock-wave-boundary layer interaction and an aircraft vortex wake. The examples show that the spatial sampling rate can be adapted to the actual flow features and that the interrogation window size can be arranged so as to follow the spatial distribution of seeding particle images and flow velocity fluctuations. In comparison with the uniform interrogation technique, the spatial resolution is locally enhanced while in poorly seeded regions the level of robustness of the analysis (signal-to-noise ratio) is kept almost constant.

  11. Dual reference point temperature interrogating method for distributed temperature sensor

    International Nuclear Information System (INIS)

    Ma, Xin; Ju, Fang; Chang, Jun; Wang, Weijie; Wang, Zongliang

    2013-01-01

    A novel method based on dual temperature reference points is presented to interrogate the temperature in a distributed temperature sensing (DTS) system. This new method is suitable to overcome deficiencies due to the impact of DC offsets and the gain difference in the two signal channels of the sensing system during temperature interrogation. Moreover, this method can in most cases avoid the need to calibrate the gain and DC offsets in the receiver, data acquisition and conversion. An improved temperature interrogation formula is presented and the experimental results show that this method can efficiently estimate the channel amplification and system DC offset, thus improving the system accuracy. (letter)

  12. Rheo: Japanese sound art interrogating digital mediality

    Directory of Open Access Journals (Sweden)

    Vandsø Anette

    2014-12-01

    Full Text Available The article asks in what way the Japanese sound artist, Ryoichi Kurokawa’s audiovisual installation, Rheo: 5 Horisonz (2010, is “digital.” Using professor Lars Elleström’s concept of “mediality,” the main claim in this article is that Rheo not only uses digital technology but also interrogates digital mediality as such. This argument is pursued in an analysis of Rheo that draws in various descriptions of digital media by N. Catherine Hayles, Lev Manovic, Bolter, and Grusin among other. The article will show how the critical potential in Rheo is directed both towards digital media as a language (Meyrowitz (or a place for representation and towards the digital as a milieu (Meyrowitz or as our culture (Gere. The overall goal of the article is not just analyse this singular art work, but also to show how such a sound art work can contribute to our understanding of our own contemporary culture as a digital culture.

  13. Repetitive Interrogation of 2-Level Quantum Systems

    Science.gov (United States)

    Prestage, John D.; Chung, Sang K.

    2010-01-01

    Trapped ion clocks derive information from a reference atomic transition by repetitive interrogations of the same quantum system, either a single ion or ionized gas of many millions of ions. Atomic beam frequency standards, by contrast, measure reference atomic transitions in a continuously replenished "flow through" configuration where initial ensemble atomic coherence is zero. We will describe some issues and problems that can arise when atomic state selection and preparation of the quantum atomic system is not completed, that is, optical pumping has not fully relaxed the coherence and also not fully transferred atoms to the initial state. We present a simple two-level density matrix analysis showing how frequency shifts during the state-selection process can cause frequency shifts of the measured clock transition. Such considerations are very important when a low intensity lamp light source is used for state selection, where there is relatively weak relaxation and re-pumping of ions to an initial state and much weaker 'environmental' relaxation of the atomic coherence set-up in the atomic sample.

  14. Interrogative Utterances in Surah Al-Baqarah

    Directory of Open Access Journals (Sweden)

    Aly Bayoumy AIi Oteify

    1993-11-01

    Full Text Available The Qur’an is singularly distinctive in its style compared to any human composition. Human eloquence, with its remarkable history in the composition of poetry, has failed to compose even a single verse like that of the Qur'an. The Qur'anic composition is a living challenge for human beings to imitate its miraculous style. This inimitable aspect of the Qur'an, among other things, proves that it was revealed by Allah (SWT to Prophet Muhammad (SAAS. In addition, the miracle of its linguistic composition was a means to declare the faith based on monotheism and the introduction of a new order and a theo-centric guidance that was meant to unite humanity. Adopting the monotheistic faith gave rise to a new community, the Muslim ummah that was able to bridge the differences between human beings in culture, race, colour and geographical boundaries. Consequently, the unique style of the Qur’an deserves a careful study. The present study investigates the use of interrogative utterances in surah al-Baqarah and their contribution to the Qur'an's rhetorical style. Hopefully, the results of this study will be useful in later investigations of other parts of the Qur' an...

  15. Neutronic measurements of radioactive waste; Les mesures neutroniques des dechets radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    Perot, B

    1997-12-31

    This document presents the general matters involved in the radioactive waste management and the different non destructive assays of radioactivity. The neutronic measurements used in the characterization of waste drums containing emitters are described with more details, especially the active neutronic interrogation assays with prompt or delayed neutron detection: physical principle, signal processing and evaluation of the detection limit. (author).

  16. Treatment and Processing of Radioactive Wastes; Traitement des Dechets Radioactifs; 041e 0411 0420 0414 ; Tratamiento de Desechos Radiactivos

    Energy Technology Data Exchange (ETDEWEB)

    Rodger, Walton A. [Chemical Engineering Division, Argonne National Laboratory, Lemont, IL (United States)

    1960-07-01

    'auteur decrit des installations type. On a envisage la possibilite d'incinerer les dechets combustibles et l'auteur decrit cette methode en precisant les modalites d'application. La mise en paquets peut souvent completer utilement la collecte des dechets. L'auteur etudie un certain nombre de procedes pour les dechets liquides. Il decrit egalement des systemes type en expliquant leur fonctionnement. Dechets de haute radioactivite - Les gaz sont parfois decharges directement dans des cheminees, mais le plus souvent on leur fait subir certains traitements. On peut, soit les epurer par des processus chimiques, retirer l'iode par reaction avec l'argent, extraire les gaz rares ou encore recourir au filtrage. Les solides fortement contamines peuvent necessiter une decontamination sur place avant la collecte. Les dechets liquides fortement radioactifs constituent a l'heure actuelle la plus forte proportion de dechets a eliminer par l'industrie. On a cherche a resoudre le probleme en reduisant le volume des dechets produits en changeant le processus ; on peut aussi concentrer les dechets produits ou bien les reduire sous forme solide - plusieurs methodes sont employees a cet effet, notamment la concentration, l'utilisation de ciment de Portland, l'adsorption sur argile ou autre materiau naturel et la calcination. L'auteur examine les problemes techniques et economiques qui se posent a propos de l'entreposage provisoire. Il peut etre necessaire de ne traiter les dechets qu'en un petit nombre d'endroits soigneusement determines. L'auteur a calcule approximativement les quantites et le materiel necessaire au deplacement. Il etudie egalement les risques afferents et les incidences financieres. (author) [Spanish] El autor examina algunos de los metodos que se han propuesto para tratar los desechos radiactivos de baja y elevada actividad. Desechos de baja actividad - Una vez diluidos, los gases se descargan en la atmosfera mediante chimeneas o se hacen pasar por filtros de elevado poder de

  17. La pelade par plaques

    Science.gov (United States)

    Spano, Frank; Donovan, Jeff C.

    2015-01-01

    Résumé Objectif Présenter aux médecins de famille des renseignements de base pour faire comprendre l’épidémiologie, la pathogenèse, l’histologie et l’approche clinique au diagnostic de la pelade par plaques. Sources des données Une recension a été effectuée dans PubMed pour trouver des articles pertinents concernant la pathogenèse, le diagnostic et le pronostic de la pelade par plaques. Message principal La pelade par plaques est une forme de perte pileuse auto-immune dont la prévalence durant une vie est d’environ 2 %. Des antécédents personnels ou familiaux de troubles auto-immuns concomitants, comme le vitiligo ou une maladie de la thyroïde, peuvent être observés dans un petit sous-groupe de patients. Le diagnostic peut souvent être posé de manière clinique en se fondant sur la perte de cheveux non cicatricielle et circulaire caractéristique, accompagnée de cheveux en « point d’exclamation » en périphérie chez ceux dont le problème en est aux premiers stades. Le diagnostic des cas plus complexes ou des présentations inhabituelles peut être facilité par une biopsie et un examen histologique. Le pronostic varie largement et de mauvais résultats sont associés à une apparition à un âge précoce, une perte importante, la variante ophiasis, des changements aux ongles, des antécédents familiaux ou des troubles auto-immuns concomitants. Conclusion La pelade par plaques est une forme auto-immune de perte de cheveux périodiquement observée en soins primaires. Les médecins de famille sont bien placés pour identifier la pelade par plaques, déterminer la gravité de la maladie et poser le diagnostic différentiel approprié. De plus, ils sont en mesure de renseigner leurs patients à propos de l’évolution clinique de la maladie ainsi que du pronostic général selon le sous-type de patients.

  18. Disposal of Radioactive Wastes in Natural Salt; Elimination des Dechets Radioactifs dans le Sel Naturel; 0423 0414 ; Evacuacion de Desechos Radiactivos en Formaciones Salinas Naturales

    Energy Technology Data Exchange (ETDEWEB)

    Parker, F. L.; Boegly, W. J.; Bradshaw, R. L.; Empson, F. M.; Hemphill, L.; Struxness, E. G.; Tamura, T. [Health Physics Division, Oak Ridge National Laboratory, Oak Ridge, TN (United States)

    1960-07-01

    diverses periodes geologiques ; 2. L'impermeabilite du sel a l'ecoulement d'eau; 3. La vaste repartition geographique du sel; 4. Les enormes quantites de sel existantes ; 5. La solidite structurale du sel; 6. La conductivite thermique relativement elevee du sel par rapport a d'autres formations geologiques generales; 7. La recuperation eventuelle de precieux produits de fission dans les dechets injectes dans le sel; 8. La facilite relative d'obtenir des excavations dans le sel par voie d'extraction, ainsi que la facilite encore plus grande et le cout reduit de la preparation dans le sol de cavites par voie de solution; 9. La faible seismicite constatee dans les zones des principaux gisements de sel. Les dechets radioactifs liquides peuvent etre emmagasines dans les cavites des formations de sel naturel, a condition que les proprietes structurales/du sel ne soient pas defavorablement influencees par les interactions chimiques, la pression, la temperature et les rayonnements. Il ressort d'etudes analytiques qu'on peut emmagasiner 3.200 litres (800 gallons) par tonne de dechets d'uranium irradie a 10.000 MWj/t, vieux de deux ans, dans une sphere de 3 metres (dix pieds) de diametre sans depasser une temperature de 93 Degree-Sign C (200 Degree-Sign F). Des essais de laboratoire montrent que les proprietes structurales et la conductivite thermique du sel gemme ne sont pas sensiblement transformees par des doses de rayonnements intenses, bien que les temperatures elevees augmentent le taux de fluage des echantillons irradies et non irradies. Les interactions chimiques de dechets liquides avec du sel donnent naissance a du chlore et a des composes gazeux du chlore, mais les volumes n'en sont pas excessifs. Les migrations des nuclides a travers le sel ainsi que la deformation de la cavite ne peuvent etre etudiees que sur place dans le sel vierge. Des maquettes a l'echelle de 1/5 ont ete essayees a Hutchinson (Kansas) dans un gisement de sel; des essais d'une certaine importance

  19. Design Concept for the Microwave Interrogation Structure in PARCS

    National Research Council Canada - National Science Library

    Dick, G. J; Klipstein, W. M; Heavner, T. P; Jefferts, S. R

    2002-01-01

    In this paper we will describe key aspects of the conceptual design of the microwave interrogation structure in the laser-cooled cesium frequency standard that is part of the Primary Atomic Reference Clock in Space (PARCS) experiment...

  20. Lawfulness of Interrogation Techniques under the Geneva Conventions

    National Research Council Canada - National Science Library

    Elsea, Jennifer K

    2004-01-01

    Allegations of abuse of Iraqi prisoners by U.S. soldiers at the Abu Ghraib prison in Iraq have raised questions about the applicability of the law of war to interrogations for military intelligence purposes...

  1. Technology for Polymer Optical Fiber Bragg Grating Fabrication and Interrogation

    DEFF Research Database (Denmark)

    Ganziy, Denis

    The aim of this project is to develop a new, high-quality interrogator for FBG sensor systems, which combines high performance with costeffectiveness. The work includes the fields of optical system design, signal processing, and algorithm investigation. We present an efficient and fast peak...... analyze and investigate errors and drawbacks, which are typical for spectrometer-based interrogators: undersampling, grating internal reflection, photo response nonuniformity, pixel crosstalk and temperature and long term drift. We propose a novel type of multichannel Digital Micromirror Device (DMD......) based interrogator, where the linear detector is replaced with a commercially available DMD, which leads to cost reduction and better performance. Original optical design, which utilizes advantages of a retro-reflect optical scheme, has been developed in Zemax. We test the presented interrogator...

  2. The role of abusive states of being in interrogation.

    Science.gov (United States)

    Putnam, Frank W

    2013-01-01

    Interrogation, the questioning of persons detained by police, military, or intelligence organizations, is designed to extract information that a subject may resist disclosing. Interrogation techniques are frequently predicated on inducing mental states of despair, dread, dependency, and debility that weaken an individual's resistance. Descriptions of techniques from 2 Central Intelligence Agency training manuals are illustrated by examples from interviews of and writings by Murat Kurnaz, who was held at Guantánamo Bay Detention Camp for 5 years. Interrogation techniques are designed to create a destabilizing sense of shock; undermine an individual's grasp on reality; and provoke internal psychological division, self-conflict, and confusion. The long-term effects of interrogation often include posttraumatic stress disorder as well as states of anxiety, depression, and depersonalization.

  3. Long period grating based refractometer with polarization-sensitive interrogation

    International Nuclear Information System (INIS)

    Eftimov, T; Bock, W; Mikulic, P; Nikolova, K

    2010-01-01

    We propose a new scheme for the interrogation of long-period fiber gratings (LPGs) which makes use of their polarization properties. Polarization-sensitive interrogation was applied to detect changes due to changes of the external refractive index by using three wavelengths on the International Telecommunication Union (ITU) grid. We show that the new approach can allow for a greater sensitivity and can be used in combination with spectral multiplexing schemes

  4. Interrogation of an object for dimensional and topographical information

    Science.gov (United States)

    McMakin, Doug L [Richland, WA; Severtsen, Ronald H [Richland, WA; Hall, Thomas E [Richland, WA; Sheen, David M [Richland, WA

    2003-01-14

    Disclosed are systems, methods, devices, and apparatus to interrogate a clothed individual with electromagnetic radiation to determine one or more body measurements at least partially covered by the individual's clothing. The invention further includes techniques to interrogate an object with electromagnetic radiation in the millimeter and/or microwave range to provide a volumetric representation of the object. This representation can be used to display images and/or determine dimensional information concerning the object.

  5. Novel applications of fast neutron interrogation methods

    International Nuclear Information System (INIS)

    Gozani, Tsahi

    1994-01-01

    The development of non-intrusive inspection methods for contraband consisting primarily of carbon, nitrogen, oxygen, and hydrogen requires the use of fast neutrons. While most elements can be sufficiently well detected by the thermal neutron capture process, some important ones, e.g., carbon and in particular oxygen, cannot be detected by this process. Fortunately, fast neutrons, with energies above the threshold for inelastic scattering, stimulate relatively strong and specific gamma ray lines from these elements. The main lines are: 6.13 for O, 4.43 for C, and 5.11, 2.31 and 1.64 MeV for N. Accelerator-generated neutrons in the energy range of 7 to 15 MeV are being considered as interrogating radiations in a variety of non-intrusive inspection systems for contraband, from explosives to drugs and from coal to smuggled, dutiable goods. In some applications, mostly for inspection of small items such as luggage, the decision process involves a rudimentary imaging, akin to emission tomography, to obtain the localized concentration of various elements. This technique is called FNA - Fast Neutron Analysis. While this approach offers improvements over the TNA (Thermal Neutron Analysis), it is not applicable to large objects such as shipping containers and trucks. For these challenging applications, a collimated beam of neutrons is rastered along the height of the moving object. In addition, the neutrons are generated in very narrow nanosecond pulses. The point of their interaction inside the object is determined by the time of flight (TOF) method, that is measuring the time elapsed from the neutron generation to the time of detection of the stimulated gamma rays. This technique, called PFNA (Pulsed Fast Neutron Analysis), thus directly provides the elemental, and by inference, the chemical composition of the material at every volume element (voxel) of the object. The various neutron-based techniques are briefly described below. ((orig.))

  6. Interrogating resilience in health systems development.

    Science.gov (United States)

    van de Pas, Remco; Ashour, Majdi; Kapilashrami, Anuj; Fustukian, Suzanne

    2017-11-01

    The Fourth Global Symposium on Health Systems Research was themed around 'Resilient and responsive health systems for a changing world.' This commentary is the outcome of a panel discussion at the symposium in which the resilience discourse and its use in health systems development was critically interrogated. The 2014-15 Ebola outbreak in West-Africa added momentum for the wider adoption of resilient health systems as a crucial element to prepare for and effectively respond to crisis. The growing salience of resilience in development and health systems debates can be attributed in part to development actors and philanthropies such as the Rockefeller Foundation. Three concerns regarding the application of resilience to health systems development are discussed: (1) the resilience narrative overrules certain democratic procedures and priority setting in public health agendas by 'claiming' an exceptional policy space; (2) resilience compels accepting and maintaining the status quo and excludes alternative imaginations of just and equitable health systems including the socio-political struggles required to attain those; and (3) an empirical case study from Gaza makes the case that resilience and vulnerability are symbiotic with each other rather than providing a solution for developing a strong health system. In conclusion, if the normative aim of health policies is to build sustainable, universally accessible, health systems then resilience is not the answer. The current threats that health systems face demand us to imagine beyond and explore possibilities for global solidarity and justice in health. © The Author 2017. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  7. 29 CFR 18.614 - Calling and interrogation of witnesses by judge.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Calling and interrogation of witnesses by judge. 18.614... interrogation of witnesses by judge. (a) Calling by the judge. The judge may, on the judge's own motion or at... thus called. (b) Interrogation by the judge. The judge may interrogate witnesses, whether called by the...

  8. Storing and evacuation of solid radioactive waste (1960); Stockage et evacuation des dechets radioactifs solides (1960)

    Energy Technology Data Exchange (ETDEWEB)

    Pomarola, J [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    The object of this paper is to present the plans under consideration for the final destination of solid radioactive wastes. 1) It is first of all necessary to provide in each centre an organised temporary storage dump. Several types of temporary dumps are suitable and can coexist in the same area; on the ground, in buildings; in basements. 2) Definitive storage. To accomplish a definitive storage arrangement it is necessary, as a function of the activity and the conditioning of the wastes, to define: - the site and the means of transport considered both inside and outside nuclear centres. The solution adopted depends on the above imperatives, and plans for definitive storage on the ground, under ground and in the sea are examined successively. Economic considerations play a large part in the decision reached. (author) [French] La presente communication a pour objet les solutions envisagees pour une destination finale des dechets radioactifs solide. 1) Il est tout d'abord necessaire de prevoir, dans chaque centre, un stockage provisoire organise. Plusieurs types de stockage previsoire peuvent convenir et coexister sur une meme aire; stockage sur le sol; stockage en batiment; stockage en sous-sol. 2) Stockage definitif. La realisation d'un stockage definitif rend necessaire, en fonction de l'activite et du conditionnement des dechets, la definition: - du site et des modes de transports envisages a l'interieur et a l'exterieur des Centres Nucleaires. Le choix des solutions decoule des imperatifs ci-dessus et on examine successivement le stockage definitif, - sur le sol; dans le sous-sol; en mer. Les considerations d'ordre economique constituent un facteur important dans le choix de la solution. (auteur)

  9. Waste Disposal Research and Development in the United States of America; L'Elimination des Dechets Radioactifs aux Etats-Unis d'Amerique: Travaux de Recherche et Progres Accomplis; 0418 0417 0423 0427 0414 ; Investigaciones y Trabajos Realizados en los Estados Unidos en Materia de Evacuacion de Desechos Radiactivos

    Energy Technology Data Exchange (ETDEWEB)

    Struxness, E. G.; Cowser, K. E.; De Laguna, W.; Jacobs, D. G.; Morton, R. J.; Tamura, T. [Health Physics Division, Oak Ridge National Laboratory, Oak Ridge, TN (United States)

    1960-07-01

    A review of the waste-disposal research and development carried out in the United States of America is given. The major research effort concerns the conversion of high-level liquid wastes into solids. At Hanford and Oak Ridge low-level wastes are disposed to the ground in pits, cribs and lagoons. Geochemical studies related to waste disposal are conducted at Hanford, Oak Ridge and the University of North Carolina. Experiments with soil columns ate described ; these are more effective for the decontamination of waste streams than either cribs or pits. The most suitable exchange materials for the soil columns are found to be vermiculite supported by rock phosphate and the latter supported by graded gravel. The progress of research work on the possibility of injecting radioactive liquid wastes into porous formations through deep wells and disposing of radioactive wastes in impermeable formations by hydraulic fracturing is outlined. (author) [French] L'auteur passe en revue les recherches effectuees aux Etats-Unis en matiere d'elimination des dechets radioactifs et les progres accomplis dans ce domaine. En matiere de recherche, on s'attache principalement a la conversion en solides des dechets liquides de haute activite. A Hanford et a Oak Ridge, les dechets de faible activite sont elimines par decharge terrestre dans des coffres, puits et depots lagunaires. Des etudes de geochimie se rapportant a l'elimination des dechets sont en cours a Hanford, a Oak Ridge et l'Universite de Caroline du Nord. Le memoire decrit les experiences faites avec des colonnes ; pour decontaminer les dechets liquides, ces dernieres sont plus efficaces que les coffres ou les puits. Les substances echangeuses d'ions les plus appropriees pour les colonnes sont vermiculite-phosphate naturel-gravier trie. L'auteur expose les progres dea travaux de recherche portant sur la possibilite d'injecter des dechets radioactifs liquides dans des formations poreuses, par decharge dans des puits profonds, et

  10. Survey of Neutron Generators for Active Interrogation

    Energy Technology Data Exchange (ETDEWEB)

    Moss, Calvin Elroy [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Myers, William L. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Sundby, Gary M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Chichester, David L. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Johnson, James P. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2017-05-02

    Some of these commercially available generators meet all of the requirements in Table 1, but there are other concerns. Most generators containing SF6 will be required to have the SF6 gas removed for shipping because of DOT regulations. However, Thermo Fisher has a DOT exemption. The P211 and B211 from Thermo Fisher meet the requirements listed in Table 1, but they are old designs and are no longer offered for sale. Also, they require 15 minutes or more of warmup before neutron output is available, and they lack a modern digital control. The nGen-300C from Starfire Industries is interesting because it is a portable system, but it uses the DD reaction for 2.5 MeV neutrons, which are not as penetrating as the 14 MeV neutrons from the DT reaction. The MP 320 from Thermo Fisher is another portable system, but the minimum pulse rate is 250 Hz, which is too fast for measurement of delayed neutrons and re-interrogation by delayed neutrons between pulses. The Genie 16 from Sodern (from France) probably meets the requirements, but the required power is probably too high for battery operation. The generators from Russia and China may be difficult to purchase, and service may not be available. The power required by some of these generators is low enough that batteries can be used. The portable units, nGen-300C and the MP320, could easily be operated with batteries. Other generators with low power requirements, as specified in the above vendors list, could possibly be operated with reason size batteries. The batteries do not need to be internal to the generator, but can be in a separate package. The availability of high capacity lithium batteries with sophisticated safety circuits makes battery operation more possible now than when lead acid batteries were used. The best path forward probably requires working with vendors of the existing systems. If Starfire Industries could be persuaded to put tritium in their nGen-300C generator, possibly in collaboration with a national

  11. Active interrogation of highly enriched uranium

    Science.gov (United States)

    Fairrow, Nannette Lea

    Safeguarding special nuclear material (SNM) in the Department of Energy Complex is vital to the national security of the United States. Active and passive nondestructive assays are used to confirm the presence of SNM in various configurations ranging from waste to nuclear weapons. Confirmation measurements for nuclear weapons are more challenging because the design complicates the detection of a distinct signal for highly enriched uranium. The emphasis of this dissertation was to investigate a new nondestructive assay technique that provides an independent and distinct signal to confirm the presence of highly enriched uranium (HEU). Once completed and tested this assay method could be applied to confirmation measurements of nuclear weapons. The new system uses a 14-MeV neutron source for interrogation and records the arrival time of neutrons between the pulses with a high efficiency detection system. The data is then analyzed by the Feynman reduced variance method. The analysis determined the amount of correlation in the data and provided a unique signature of correlated fission neutrons. Measurements of HEU spheres were conducted at Los Alamos with the new system. Then, Monte Carlo calculations were performed to verify hypothesis made about the behavior of the neutrons in the experiment. Comparisons of calculated counting rates by the Monte Carlo N-Particle Transport Code (MCNP) were made with the experimental data to confirm that the measured response reflected the desired behavior of neutron interactions in the highly enriched uranium. In addition, MCNP calculations of the delayed neutron build-up were compared with the measured data. Based on the results obtained from this dissertation, this measurement method has the potential to be expanded to include mass determinations of highly enriched uranium. Although many safeguards techniques exist for measuring special nuclear material, the number of assays that can be used to confirm HEU in shielded systems is

  12. suPAR

    DEFF Research Database (Denmark)

    Eugen-Olsen, Jesper; Giamarellos-Bourboulis, Evangelos J

    2015-01-01

    Investigation of biomarkers that can promptly predict unfavourable outcome of critically illness is an emerging necessity taking into consideration the need for early intervention, the shortage of available beds in intensive care units and the considerable cost of hospitalisation. The most...... promising biomarker is soluble urokinase-type plasminogen activator receptor (suPAR). Three studies in large populations of critically ill patients and patients admitted to the emergency department have shown that concentrations >12ng/mL can safely predict unfavourable outcome. This review presents...

  13. Parálisis cerebral :

    OpenAIRE

    Cabrero Izquierdo, María del Carmen

    2012-01-01

    Se aborda el tema de la parálisis cerebral definiendo qué es, clasificando los tipos de parálisis dependiendo de la afectación y las características principales. Se explican algunos de sus tratamientos, se dan sistemas alternativos y/o aumentativos de comunicación para un alumno con PC (parálisis cerebral).

  14. Innocence and resisting confession during interrogation: effects on physiologic activity.

    Science.gov (United States)

    Guyll, Max; Madon, Stephanie; Yang, Yueran; Lannin, Daniel G; Scherr, Kyle; Greathouse, Sarah

    2013-10-01

    Innocent suspects may not adequately protect themselves during interrogation because they fail to fully appreciate the danger of the situation. This experiment tested whether innocent suspects experience less stress during interrogation than guilty suspects, and whether refusing to confess expends physiologic resources. After experimentally manipulating innocence and guilt, 132 participants were accused and interrogated for misconduct, and then pressured to confess. Systolic and diastolic blood pressure (SBP, DBP), heart rate (HR), respiratory sinus arrhythmia (RSA), and preejection period (PEP) responses quantified stress reactions. As hypothesized, the innocent evidenced smaller stress responses to interrogation for SBP, DBP, HR, and RSA than did the guilty. Furthermore, innocents who refused to confess exhibited greater sympathetic nervous system activation, as evidenced by shorter PEPs, than did innocent or guilty confessors. These findings suggest that innocent suspects underestimate the threat of interrogation and that resisting pressures to confess can diminish suspects' physiologic resources and lead to false confessions. PsycINFO Database Record (c) 2013 APA, all rights reserved

  15. Development of fiber optic sensing interrogators for launchers

    Science.gov (United States)

    Plattner, M. P.; Buck, T. C.; Eder, B.; Reutlinger, A.; McKenzie, I.

    2017-11-01

    We present our work about the development of two complementary interrogation schemes based on fiber optic sensing for the use of structural and thermal monitoring of Ariane launchers. The advantages of fiber optic sensing in particular light-weight, immunity to electromagnetic interferences and the possibility of sensor distribution along optical fibers are driving factors for utilization of this technology in space crafts [1]. The edge-filter (EF) and scanning-laser (SL) interrogators for determination of the mean wavelength of fiber Bragg grating (FBG) sensors have been implemented as two separate demonstrators. Within this paper we describe the functional principles of both interrogators. Furthermore we present test results where the developed systems have been used for readout of FBG sensors which are implemented in an Ariane structural demonstrator during thermal, thermal-vacuum and vibration tests. Functionality of both systems is demonstrated and their potential for further development towards space qualified systems is shown. Since the performance characteristics of the two systems are different from each other, they are dedicated for different sensing applications on a launcher. The EF sensor interrogator provides a sample rate of 20 kHz at a number of 4 connected sensors and supports parallel readout and aliasing free operation. Therefore it is best suited for high priority measurement. Structural monitoring which requires the acquisition of real time sensor information in order to support control of the launcher is one operation area for a future EF system. The SL interrogator provides an overall measurement rate of 1 kHz at a number of 24 connected sensors distributed on three sensor channels. It can be adapted to any sensors that have design wavelengths lying within the output spectrum of the laser diode. Furthermore the number of overall sensors to be read out with this system can be adapted easily. Thermal mapping of satellite panels is one possible

  16. The pretreatment of uranium ores by physical processing; Les problemes de la preconcentration des minerais d'uranium par voie physique

    Energy Technology Data Exchange (ETDEWEB)

    Vuchot, L; Ginocchio, A; Hubert, G; Roques, E; Sandier, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    After giving an outline of the classical means of physical processing - granulometry, gravimetry, flotation, magnetism, electrostatics, the authors study the methods peculiar to radioactive ores: pretreatment in batches (counting cylinders) or stone by stone (electronic sorting belt). The three factors to be considered in any treatment operation are studied (cost of the operation, metal recovery, ratio of concentration), as well as their bearing on the cost and the productivity of the following operations. Making use of radioactivity in order to find out instantaneously the approximate grade of the obtained product makes it possible to reduce costs and improve results by setting up total automation. (author) [French] Apres un apercu des procedes classiques de concentration physique des minerais - granulometrie, gravimetrie, flottation, magnetisme et electrostatique, les auteurs s'attachent aux methodes propres aux minerais radioactifs: preconcentration par lots (cylindre de comptage) ou caillou par caillou (bande de triage electronique). Les trois facteurs a considerer lors de toute operation de traitement sont etudies (prix de revient de l'operation, rendement metal et rendement poids), ainsi que leurs repercussions sur les prix de revient et rendements des traitements ulterieurs. L'utilisation de la radioactivite pour determiner instantanement la teneur approximative des produits obtenus permet d'envisager de reduire les prix de revient et d'ameliorer les resultats par une automatisation totale. (auteur)

  17. The pretreatment of uranium ores by physical processing; Les problemes de la preconcentration des minerais d'uranium par voie physique

    Energy Technology Data Exchange (ETDEWEB)

    Vuchot, L.; Ginocchio, A.; Hubert, G.; Roques, E.; Sandier, J. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    After giving an outline of the classical means of physical processing - granulometry, gravimetry, flotation, magnetism, electrostatics, the authors study the methods peculiar to radioactive ores: pretreatment in batches (counting cylinders) or stone by stone (electronic sorting belt). The three factors to be considered in any treatment operation are studied (cost of the operation, metal recovery, ratio of concentration), as well as their bearing on the cost and the productivity of the following operations. Making use of radioactivity in order to find out instantaneously the approximate grade of the obtained product makes it possible to reduce costs and improve results by setting up total automation. (author) [French] Apres un apercu des procedes classiques de concentration physique des minerais - granulometrie, gravimetrie, flottation, magnetisme et electrostatique, les auteurs s'attachent aux methodes propres aux minerais radioactifs: preconcentration par lots (cylindre de comptage) ou caillou par caillou (bande de triage electronique). Les trois facteurs a considerer lors de toute operation de traitement sont etudies (prix de revient de l'operation, rendement metal et rendement poids), ainsi que leurs repercussions sur les prix de revient et rendements des traitements ulterieurs. L'utilisation de la radioactivite pour determiner instantanement la teneur approximative des produits obtenus permet d'envisager de reduire les prix de revient et d'ameliorer les resultats par une automatisation totale. (auteur)

  18. Subthreshold neutron interrogator for detection of radioactive materials

    Science.gov (United States)

    Evans, Michael L.; Menlove, Howard O.; Baker, Michael P.

    1980-01-01

    A device for detecting fissionable material such as uranium in low concentrations by interrogating with photoneutrons at energy levels below 500 keV, and typically about 26 keV. Induced fast neutrons having energies above 500 keV by the interrogated fissionable material are detected by a liquid scintillator or recoil proportional counter which is sensitive to the induced fast neutrons. Since the induced fast neutrons are proportional to the concentration of fissionable material, detection of induced fast neutrons indicate concentration of the fissionable material.

  19. A review of conventional explosives detection using active neutron interrogation

    International Nuclear Information System (INIS)

    Whetstone, Z.D.; Kearfott, K.J.

    2014-01-01

    Conventional explosives are relatively easy to obtain and may cause massive harm to people and property. There are several tools employed by law enforcement to detect explosives, but these can be subverted. Active neutron interrogation is a viable alternative to those techniques, and includes: fast neutron analysis, thermal neutron analysis, pulsed fast/thermal neutron analysis, neutron elastic scatter, and fast neutron radiography. These methods vary based on neutron energy and radiation detected. A thorough review of the principles behind, advantages, and disadvantages of the different types of active neutron interrogation is presented. (author)

  20. New instruments and methods for measuring the concentration of radioactive products in the atmosphere; Appareils recents et methodes nouvelles pour la mesure de la concentration des produits radioactifs dans l'atmosphere

    Energy Technology Data Exchange (ETDEWEB)

    Jehanno, C; Blanc, A; Lallemant, C; Roux, G [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1959-07-01

    ) [French] Differents enregistreurs pour aerosols radioactifs ont ete realises pour mesurer la pollution de l'atmosphere des laboratoires ou l'atmosphere exterieure. EAR 600. - Permet de mesurer en continu instantanement et 3 a 10 heures apres le prelevement des concentrations d'aerosols emetteurs {alpha} ou {beta} allant de quelques 10{sup -11} a quelques 10{sup -8} curies par metre cube d'air. EAR 800. - Permet de mesurer en continu des concentrations d'aerosols emetteurs {alpha} allant de 10{sup -11} a 10{sup -5} curie par metre cube d'air, et des concentrations d'aerosols emetteurs {beta} allant de 10{sup -11} a 10{sup -1} curie par metre cube d'air. EAR PLUTONIUM. - Permet de detecter en quelques minutes 1000 DMP (2.10{sup -9} curie par metre cube) et en 8 heures 1 DMP (2.10{sup -12} curie par metre cube). Deux methodes sont utilisees pour separer l'activite due au plutonium de celle due aux derives du radon et du thoron: a) par discrimination d'amplitude, b) par les coincidences (a,b) RaC' et ThC-ThC'. SP 4. - Monte sur jeep, cet ensemble permet la mesure de l'irradiation produite au sol par le panache des piles. La sensibilite est de 5{mu}R/h. A.D.I.R. - Cet appareil autonome et portatif est destine a la mesure instantanee des teneurs en radon de l'atmosphere des mines. Il permet de mesurer des teneurs de l'air variant entre 0,4 et 400.10{sup -10} curie par litre d'air (0,4 et 400 DPM). La mesure des retombees radioactives est faite apres collection de cette activite par un pluviometre special comportant une surface adhesive et une cartouche de resines echangeuses d'ions. La radioactivite des retombees varie entre quelques 10{sup -9} et quelques 10{sup -7} curie par metre carre et par mois. La mesure des concentrations de l'atmosphere en produits de fission est faite apres collection sur papier filtre. Les concentrations mesurees dans l'air au niveau du sol varient entre 10{sup -13} et 10{sup -12} curie par metre cube. (auteur)

  1. Interrogative suggestibility, confabulation, and acquiescence in people with mild learning disabilities (mental handicap): implications for reliability during police interrogations.

    Science.gov (United States)

    Clare, I C; Gudjonsson, G H

    1993-09-01

    In order to assess a criminal suspect's ability to make a reliable statement, performance on three measures--interrogative suggestibility, confabulation and acquiescence--may be used. This paper presents preliminary data on these measures for people with mild learning disabilities (Full Scale IQ [FSIQ]: 57-75). It was found that they were more suggestible than their average ability counterparts (FSIQ: 83-111) because they were much more susceptible to 'leading questions'. They also confabulated more and were more acquiescent. Overall, the data emphasized their potential vulnerability to giving erroneous testimony during interrogations.

  2. Interrogating Your Wisdom of Practice to Improve Classroom Practices

    Science.gov (United States)

    Chappell, Philip

    2017-01-01

    This article presents a heuristic for language teachers to articulate and explore their fundamental theories of and philosophical stances towards language, language learning, and language teaching. It includes tools with which teachers can interrogate those theories, weighing them up against their actual classroom practices. Through presenting…

  3. Learning about Posterior Probability: Do Diagrams and Elaborative Interrogation Help?

    Science.gov (United States)

    Clinton, Virginia; Alibali, Martha W.; Nathan, Mitchell J.

    2016-01-01

    To learn from a text, students must make meaningful connections among related ideas in that text. This study examined the effectiveness of two methods of improving connections--elaborative interrogation and diagrams--in written lessons about posterior probability. Undergraduate students (N = 198) read a lesson in one of three questioning…

  4. Postmortem ICD interrogation in mode of death classification.

    Science.gov (United States)

    Nikolaidou, Theodora; Johnson, Miriam J; Ghosh, Justin M; Marincowitz, Carl; Shah, Saumil; Lammiman, Michael J; Schilling, Richard J; Clark, Andrew L

    2018-04-01

    The definition of sudden death due to arrhythmia relies on the time interval between onset of symptoms and death. However, not all sudden deaths are due to arrhythmia. In patients with an implantable cardioverter defibrillator (ICD), postmortem device interrogation may help better distinguish the mode of death compared to a time-based definition alone. This study aims to assess the proportion of "sudden" cardiac deaths in patients with an ICD that have confirmed arrhythmia. We conducted a literature search for studies using postmortem ICD interrogation and a time-based classification of the mode of death. A modified QUADAS-2 checklist was used to assess risk of bias in individual studies. Outcome data were pooled where sufficient data were available. Our search identified 22 studies undertaken between 1982 and 2015 with 23,600 participants. The pooled results (excluding studies with high risk of bias) suggest that ventricular arrhythmias are present at the time of death in 76% of "sudden" deaths (95% confidence interval [CI] 67-85; range 42-88). Postmortem ICD interrogation identifies 24% of "sudden" deaths to be nonarrhythmic. Postmortem device interrogation should be considered in all cases of unexplained sudden cardiac death. © 2018 Wiley Periodicals, Inc.

  5. Basic concepts underlying fast-neutron-based contraband interrogation technology

    International Nuclear Information System (INIS)

    Fink, C.L.; Guenther, P.T.; Smith, D.L.

    1992-01-01

    All accelerator-based fast-neutron contraband interrogation systems have many closely interrelated subsystems, whose performance parameters will be critically interdependent. For optimal overall performance, a systems analysis design approach is required. This paper provides a general overview of the interrelationships and the tradeoffs to be considered for optimization of nonaccelerator subsystems

  6. "Enhanced" interrogation of detainees: do psychologists and psychiatrists participate?

    Science.gov (United States)

    Halpern, Abraham L; Halpern, John H; Doherty, Sean B

    2008-09-25

    After revelations of participation by psychiatrists and psychologists in interrogation of prisoners at Guantánamo Bay and Central Intelligence Agency secret detention centers, the American Psychiatric Association and the American Psychological Association adopted Position Statements absolutely prohibiting their members from participating in torture under any and all circumstances, and, to a limited degree, forbidding involvement in interrogations. Some interrogations utilize very aggressive techniques determined to be torture by many nations and organizations throughout the world. This paper explains why psychiatrists and psychologists involved in coercive interrogations violate the Geneva Conventions and the laws of the United States. Whether done with ignorance of professional ethical obligations or not, these psychiatrists and psychologists have crossed an ethical barrier that may best be averted from re-occurring by teaching medical students and residents in all medical specialties about the ethics principles stemming from the 1946-1947 Nuremberg trials and the Geneva Conventions, together with the Ethics Codes of the World Medical Association and the American Medical Association; and, with regard to psychiatric residents and psychological trainees, by the teaching about The Principles of Medical Ethics With Annotations Especially Applicable to Psychiatry and the Ethical Principles of Psychologists and Code of Conduct, respectively. In this way, all physicians and psychologists will clearly understand that they have an absolute moral obligation to "First, do no harm" to the human beings they professionally encounter.

  7. "Enhanced" interrogation of detainees: do psychologists and psychiatrists participate?

    Directory of Open Access Journals (Sweden)

    Halpern John H

    2008-09-01

    Full Text Available Abstract After revelations of participation by psychiatrists and psychologists in interrogation of prisoners at Guantánamo Bay and Central Intelligence Agency secret detention centers, the American Psychiatric Association and the American Psychological Association adopted Position Statements absolutely prohibiting their members from participating in torture under any and all circumstances, and, to a limited degree, forbidding involvement in interrogations. Some interrogations utilize very aggressive techniques determined to be torture by many nations and organizations throughout the world. This paper explains why psychiatrists and psychologists involved in coercive interrogations violate the Geneva Conventions and the laws of the United States. Whether done with ignorance of professional ethical obligations or not, these psychiatrists and psychologists have crossed an ethical barrier that may best be averted from re-occurring by teaching medical students and residents in all medical specialties about the ethics principles stemming from the 1946–1947 Nuremberg trials and the Geneva Conventions, together with the Ethics Codes of the World Medical Association and the American Medical Association; and, with regard to psychiatric residents and psychological trainees, by the teaching about The Principles of Medical Ethics With Annotations Especially Applicable to Psychiatry and the Ethical Principles of Psychologists and Code of Conduct, respectively. In this way, all physicians and psychologists will clearly understand that they have an absolute moral obligation to "First, do no harm" to the human beings they professionally encounter.

  8. On the aesthetics of mimicry and proliferation: interrogations of ...

    African Journals Online (AJOL)

    This article examines innovative modes of interrogating spectacles of State power in postcolonial dictatorship novels. Authoritarian power in the postcolonial public sphere perpetuates itself through practices that reiterate the prerogatives of State reason, national progress, national unity and the indispensability of the ...

  9. Interrogating Infanticide/ Child Euthanasia in the Roman Christian ...

    African Journals Online (AJOL)

    The purpose of this paper is an attempt to examine infanticide practices in the Roman Christian era and interrogate infanticide and child euthanasia in the same era. It also attempts to point out infanticide practices in Abuja and makes a distinction between infanticide and child euthanasia in Abuja. The study employed ...

  10. Interrogating Public Sphere and Popular Culture as Theoretical ...

    African Journals Online (AJOL)

    Because of its theoretical roots in Western liberal thinking, scholars in African studies such as Comaroffs, Mamdani and Ekeh have vigorously debated the extent to which the concept of civil society is useful in explaining and interrogating developments in Africa. However, the concept of the public sphere has been subjected ...

  11. Methods and systems using encapsulated tracers and chemicals for reservoir interrogation and manipulation

    Science.gov (United States)

    Roberts, Jeffery; Aines, Roger D; Duoss, Eric B; Spadaccini, Christopher M

    2014-11-04

    An apparatus, method, and system of reservoir interrogation. A tracer is encapsulating in a receptacle. The receptacle containing the tracer is injected into the reservoir. The tracer is analyzed for reservoir interrogation.

  12. Disposal of Waste into the Atmosphere; Elimination des Dechets Radioactifs dans l'Atmosphere; 0423 0414 0410 ; Evacuacion de Desechos Radiactivos en la Atmosfera

    Energy Technology Data Exchange (ETDEWEB)

    Schulte, H. F. [Health Division, Los Alamos Scientific Laboratory, University of California, Los Alamos, NM (United States)

    1960-07-01

    The atmosphere can be compared to the hydrosphere and the lithosphere as a recipient of wastes, but the presence of airborne wastes is of more immediate concern to human life. There are two very distinct problems presented by atmospheric pollution, (1) that in the immediate vicinity of a plant and (2) the world-wide problem from long-term, widespread air pollution. Short- range problems have existed for many years as a result of non-radioactive wastes such as coal-smoke, sulphur dioxide and hydrogen fluoride. However, only in recent years has this problem received intense scientific study. Meteorological conditions play an important role in this problem. In some cases emission rates have been controlled in keeping with meteorological predictions. However, the basic solution is still that of reducing emission rates to the lowest possible values. (author) [French] L'atmosphere peut etre comparee a l'hydrosphere et a la lithosphere en tant que receptacle eventuel de dechets, mais la presence de dechets en suspension dans l'air est plus preoccupante pour la vie humaine. La pollution atmospherique pose deux problemes nettement distincts: 1) un probleme de portee limitee concernant le voisinage immediat d'une usine, et 2) un probleme de portee mondiale, savoir la pollution largement repandue, a long terme, de l'atmosphere. Des problemes de portee limitee se sont poses depuis de nombreuses annees ; ils sont lies a la presence dans l'atmosphere de dechets non radioactifs, tels que les fumees produites par le charbon, l'anhydride sulfurique et l'anhydride fluorhydrique. Cependant, ce n'est que recemment que ce probleme a ete soumis a une etude scientifique poussee. Les conditions meteorologiques jouent la un role important. Dans certains cas, les intensites d'emission ont ete controlees en tablant sur les previsions meteorologiques. Toutefois, la solution fondamentale est encore de reduire l'intensite d'emission a la plus faible valeur possible. (author) [Spanish] Si bien

  13. Disposal of the radioactive effluents at the 'Commissariat a l'Energie Atomique'. Treatment leading to evacuation into a river; Probleme du rejet des residus radioactifs liquides au CEA. Traitements aboutissant a des rejets en riviere

    Energy Technology Data Exchange (ETDEWEB)

    Duhamel,; Menoux,; Candillon, [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    loaded water, 10) Impot elements other than Sr{sup 90} are also studied. (author) [French] Le probleme du traitement des residus radioactifs liquides au CEA est envisage sous l'angle du rejet ultime en riviere dans des conditions optima permettant de satisfaire aux Normes de la protection. 2) A Saclay, ou l'on ne dispose que d'un etang ou l'eau ne se renouvelle pas, les liquides epures sont envoyes par camion citerne a Fontenay-aux-Roses, ou ils sont deverses provisoirement - dans les egouts - en attendant qu'un point de rejet en Seine ait ete determine. 3) Au Bouchet, les eaux residuaires de l'Usine de traitement de minerais d'urano-thorianite devront etre traitees en deux temps de facon a separer le radium dans une premiere phase, ce qui facilitera l'epuration au cours de la deuxieme phase. 4) En vue des futurs rejets a Marcoule, une etude a ete conduite a Saclay, sur des effluents synthetiques - type Marcoule - ayant pour but de mettre au point des procedes d'elimination selective du Sr d'une part, du Cs d'autre part, par coprecipitation. 5) Dans le cas general du rejet ultime en riviere, les problemes suivants sont successivement envisages: - predilution entre les bassins de stockage des eaux epurees et le fleuve; - mode d'injection dans le fleuve; - dilution dans le fleuve (etude prealable par traceurs); - evolution de l'activite dans les eaux du fleuve (adsorption par les organismes inertes ou vivants, contamination des berges); - incidence sur le choix d'un site; - dilution isotopique. 6) Ce dernier probleme est specialement detaille. 7) La teneur de l'eau en un element donne conditionne la dilution isotopique de son isotope radioactif. L'analyse decelant une carence, il est possible d'y suppleer par des rejets d'isotope stable. 8) Cette methode conduit en certains cas a des analyses delicates (en particulier dans le cas du {sup 90}Sr), la teneur en isotope stable necessaire a une forte dilution isotopique restant faible (ce qui est d'ailleurs un avantage). 9

  14. Treatment of Radioactive Waste at Japan's Atomic Energy Research Institute; Traitement des Dechets Radioactifs a l'Institut Japonais de Recherches sur l'Energie Atomique; 041e 0411 0420 0410 0411 041e 0422 041a 0410 0420 0410 0414 ; Tratamiento de los Desechos Radiactivos en el Instituto de Investigaciones sobre Energia Atomica del Japon

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Yutaka [University of Toyko (Japan); Japan Atomic Energy Research Institute (Japan); Ito, Masukuni F.; Ishihara, Takehiko; Mitsuishi, Nobuo [Sadahiro Sakata, Japan Atomic Energy Research Institute (Japan)

    1960-07-01

    The paper describes the origin, nature and treatment of the radioactive wastes. The very low-level liquid waste is diluted and released to the sea, while the low- and medium-level liquid waste is treated by flocculation, evaporation and ion-exchange methods. The solid waste is collected and the combustible waste incinerated. (author) [French] Le present memoire decrit l'origine, la nature et le traitement des dechets radioactifs. Les dechets liquides de tres faible activite sont dilues et evacues dans la mer, tandis que les dechets liquides d'activite faible et moyenne sont traites par des methodes de floculation, d'evaporation et d'echange d'ions. Les dechets solides sont rassembles et les dechets combustibles sont incineres. (author) [Spanish] Los aiutores describen el origen y la naturaleza de los desechos radiactivos, asi como los metodos seguidos para su tratamiento. Los desechos liquidos de muy bajo nivel de actividad se diluyen primero y luego se descargan en el mar, en tanto que los desechos liquidos de bajo y mediano nivel se tratan mediante procedimientos de floculacion, evaporacion e intercambio ionico. Los residuos solidos se acopian y los residuos combustibles se incineran. (author) [Russian] V dokumente opisyvajutsja priroda i harakter radioaktivnyh othodov i metody ih obrabotki. Zhidkie othody ochen' nizkoj aktivnosti razbavljajutsja i otvodjatsja v morja, a zhidkie othody nizkoj i srednej aktivnosti obrabatyvajutsja metodami flokkuljacii, vyparivanija i ionnogo obmena. Tverdye othody sobirajutsja i po vozmozhnosti szhigajutsja. (author)

  15. Modelling of nuclear glasses by classical and ab initio molecular dynamics; Modelisation de verres intervenant dans le conditionnement des dechets radioactifs par dynamiques moleculaires classique et ab initio

    Energy Technology Data Exchange (ETDEWEB)

    Ganster, P

    2004-10-15

    A calcium aluminosilicate glass of molar composition 67 % SiO{sub 2} - 12 % Al{sub 2}O{sub 3} - 21 % CaO was modelled by classical and ab initio molecular dynamics. The size effect study in classical MD shows that the systems of 100 atoms are more ordered than the larger ones. These effects are mainly due to the 3-body terms in the empirical potentials. Nevertheless, these effects are small and the structures generated are in agreement with experimental data. In such kind of glass, we denote an aluminium avoidance and an excess of non bridging oxygens which can be compensated by tri coordinated oxygens. When the dynamics of systems of 100 and 200 atoms is followed by ab initio MD, some local arrangements occurs (bond length, angular distributions). Thus, more realistic vibrational properties are obtained in ab initio MD. The modelling of thin films shows that aluminium atoms extend to the most external part of the surface and they are all tri-coordinated. Calcium atoms are set in the sub layer part of the surface and they produce a depolymerization of the network. In classical MD, tri-coordinated aluminium atoms produce an important electric field above the surface. With non bridging oxygens, they constitute attractive sites for single water molecules. (author)

  16. Production of chemically reactive radioactive ion beams through on-line separation; Production de faisceaux d'ions radioactifs chimiquement reactifs par separation en ligne

    Energy Technology Data Exchange (ETDEWEB)

    Joinet, A

    2003-10-01

    The ISOL (isotope separation on line) allows the production of secondary radioactive ion beams through spallation or fragmentation or fission reactions that take place in a thick target bombarded by a high intensity primary beam. The challenge is to increase the intensity and purity of the radioactive beam. The optimization of the system target/source requires the right choice of material for the target by taking into account the stability of the material, its reactivity and the ionization method used. The target is an essential part of the system because radioactive elements are generated in it and are released more or less quickly. Tests have been made in order to select the best fitted material for the release of S, Se, Te, Ge and Sn. Materials tested as target filling are: ZrO{sub 2}, Nb, Ti, V,TiO{sub 2}, CeO{sub x}, ThO{sub 2}, C, ZrC{sub 4} and VC). Other molecules such as: COSe, COS, SeS, COTe, GeS, SiS, SnS have been studied to ease the extraction of recoil nuclei (Se, S, Te, Ge and Sn) produced inside the target.

  17. Production of chemically reactive radioactive ion beams through on-line separation; Production de faisceaux d'ions radioactifs chimiquement reactifs par separation en ligne

    Energy Technology Data Exchange (ETDEWEB)

    Joinet, A

    2003-10-01

    The ISOL (isotope separation on line) allows the production of secondary radioactive ion beams through spallation or fragmentation or fission reactions that take place in a thick target bombarded by a high intensity primary beam. The challenge is to increase the intensity and purity of the radioactive beam. The optimization of the system target/source requires the right choice of material for the target by taking into account the stability of the material, its reactivity and the ionization method used. The target is an essential part of the system because radioactive elements are generated in it and are released more or less quickly. Tests have been made in order to select the best fitted material for the release of S, Se, Te, Ge and Sn. Materials tested as target filling are: ZrO{sub 2}, Nb, Ti, V,TiO{sub 2}, CeO{sub x}, ThO{sub 2}, C, ZrC{sub 4} and VC). Other molecules such as: COSe, COS, SeS, COTe, GeS, SiS, SnS have been studied to ease the extraction of recoil nuclei (Se, S, Te, Ge and Sn) produced inside the target.

  18. 25 CFR 11.303 - Notification of rights prior to custodial interrogation.

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Notification of rights prior to custodial interrogation. 11.303 Section 11.303 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR LAW AND ORDER... to custodial interrogation. Prior to custodial interrogation, the suspect shall be advised of the...

  19. 75 FR 67632 - Defense Federal Acquisition Regulation Supplement; Prohibition on Interrogation of Detainees by...

    Science.gov (United States)

    2010-11-03

    ...-AG88 Defense Federal Acquisition Regulation Supplement; Prohibition on Interrogation of Detainees by... National Defense Authorization Act for Fiscal Year 2010 (Pub. L. 111-84) prohibits the interrogation of..., to add DFARS 237.173, Prohibition on Interrogation of Detainees by Contractor Personnel, adding a...

  20. 29 CFR 18.611 - Mode and order of interrogation and presentation.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Mode and order of interrogation and presentation. 18.611... of interrogation and presentation. (a) Control by judge. The judge shall exercise reasonable control... interrogation and presentation effective for the ascertainment of the truth, (2) Avoid needless consumption of...

  1. From third degree to third generation interrogation strategies: putting science into the art of criminal interviewing

    Science.gov (United States)

    2017-03-01

    tacitly suggest that a confession is the fastest and best way to end the interrogation .73 71 Ibid...Kelly, and Miller found approximately 45 percent of civilian interrogators use it as well.292 Because this percentage suggests the technique is...TO THIRD-GENERATION INTERROGATION STRATEGIES: PUTTING SCIENCE INTO THE ART OF CRIMINAL INTERVIEWING by Desmond S. O’Neill March 2017

  2. Improving Reasoning and Recall: The Differential Effects of Elaborative Interrogation and Mnemonic Elaboration.

    Science.gov (United States)

    Scruggs, Thomas E.; And Others

    1993-01-01

    Fifty-three adolescents with learning disabilities or mild mental retardation were taught reasons for dinosaur extinction. Those taught in a mnemonic elaborative interrogation condition recalled more reasons than did students who received direct teaching. Students in elaborative interrogation and mnemonic elaborative interrogation groups recalled…

  3. Elusloom lennukiga puhkusele / Inge Parring

    Index Scriptorium Estoniae

    Parring, Inge

    2003-01-01

    Ilmunud ka: Delovõje Vedomosti 1. okt. lk. 13. Air Cargo Estonia/ACE Logisticsi müügijuht Inge Parring tutvustab elusloomade transpordivõimalusi. Vt. samas: Loomade transportimiseks vajalikud dokumendid

  4. Cadarache LOR (liquides organiques radioactifs) treatment by a solidification process using NOCHAR polymers

    International Nuclear Information System (INIS)

    Vaudey, Claire-Emilie; Renou, Sebastien; Kelley, Dennis; Cochaud, Chantal; Serrano, Roger

    2013-01-01

    In France, two options can be considered to handle the Very Low Level Waste (VLLW) and the Low Level Waste (LLW). The first one is the incineration at CENTRACO facility and the second one is the disposal at ANDRA sites. The waste acceptance in these two channels is dependent upon the adequacy between the waste characteristics (physical chemistry and radiological) and the channel specifications. If the waste characteristics and the channel specifications (presence of significant quantities of halogens, complexing agents, organic components... or/and high activity limits) are incompatible, an alternative solution have to be identify. It consists of a waste pre-treatment process. For Cadarache LOR (Liquides Organiques Radioactifs) waste streams, two radioactive scintillation cocktails have to be treated. They are composed of a mix of organic liquids and water: for the first one, 19 % of organic compounds (xylene, mesitylene, diphenyloxazole, TBP...) and 86.9 % of water, and for the second one, 23 % of organic compounds (TBP...) and 77 % of water. They contain halogens (chlorine and fluorine), complexants agents (nitrate, sulphate, oxalate and formate) and have got αβγ spectra with mass activities equal to some 100 Bq/g. Therefore, tritium is also present. As a consequence, in order for storage acceptance at the ANDRA site, it is necessary to pre-treat the waste. An adequate solution seems to be a solidification process using NOCHAR polymers. Indeed, NOCHAR polymers correspond to an important variety of products applied to the treatment of radioactive aqueous and organic liquids (solvent, oil, solvent/oil mixing ...) and sludge through a mechanical and chemical solidification process. For Cadarache LOR, N910 and N960 respectively dedicated to the organic and aqueous liquids solidification are considered. With the N910, the organic waste solidification occurs in two steps. As the organic liquid travels moves through the polymer strands, the strands swell and

  5. NOCHAR Polymers: An Aqueous and Organic Liquid Solidification Process for Cadarache LOR (Liquides Organiques Radioactifs) - 13195

    International Nuclear Information System (INIS)

    Vaudey, Claire-Emilie; Renou, Sebastien; Porco, Julien; Kelley, Dennis; Cochaud, Chantal; Serrano, Roger

    2013-01-01

    To handle the Very Low Level Waste (VLLW) and the Low Level Waste (LLW) in France, two options can be considered: the incineration at CENTRACO facility and the disposal facility on ANDRA sites. The waste acceptance in these radwaste routes is dependent upon the adequacy between the waste characteristics (physical chemistry and radiological) and the radwaste route specifications. If the waste characteristics are incompatible with the radwaste route specifications (presence of significant quantities of chlorine, fluorine, organic component etc or/and high activity limits), it is necessary to find an alternative solution that consists of a waste pre-treatment process. In the context of the problematic Cadarache LOR (Liquides Organiques Radioactifs) waste streams, two radioactive scintillation cocktails have to be treated. The first one is composed of organic liquids at 13.1 % (diphenyloxazol, mesitylene, TBP, xylene) and water at 86.9 %. The second one is composed of TBP at 8.6 % and water at 91.4 %. They contain chlorine, fluorine and sulphate and have got alpha/beta/gamma spectra with mass activities equal to some kBq.g -1 . Therefore, tritium is present and creates the second problematic waste stream. As a consequence, in order for disposal acceptance at the ANDRA site, it is necessary to pre-treat the waste. The NOCHAR polymers as an aqueous and organic liquid solidification process seem to be an adequate solution. Indeed, these polymers constitute an important variety of products applied to the treatment of radioactive aqueous and organic liquids (solvent, oil, solvent/oil mixing etc) and sludge through a mechanical and chemical solidification process. For Cadarache LOR, N910 and N960 respectively dedicated to the organic and aqueous liquids solidification are considered. With the N910, the organic waste solidification occurs in two steps. As the organic liquid travels moves through the polymer strands, the strands swell and immobilise the liquid. Then as the

  6. Par Pond vegetation status 1996

    International Nuclear Information System (INIS)

    Mackey, H.E. Jr.; Riley, R.S.

    1996-12-01

    The water level of Par Pond was lowered approximately 20 feet in mid-1991 in order to protect downstream residents from possible dam failure suggested by subsidence on the downstream slope of the dam and to repair the dam. This lowering exposed both emergent and nonemergent macrophyte beds to drying conditions resulting in extensive losses. A survey of the newly emergent, shoreline aquatic plant communities of Par Pond began in June 1995, three months after the refilling of Par Pond to approximately 200 feet above mean sea level. These surveys continued in July, September, and late October, 1995, and into the early spring and late summer of 1996. Communities similar to the pre-drawdown, Par Pond aquatic plant communities continue to become re-established. Emergent beds of maidencane, lotus, waterlily, watershield, and Pontederia are extensive and well developed. Measures of percent cover, width of beds, and estimates of area of coverage with satellite data indicate regrowth within two years of from 40 to 60% of levels prior to the draw down. Cattail occurrence continued to increase during the summer of 1996, especially in the former warm arm of Par Pond, but large beds common to Par Pond prior to the draw down still have not formed. Lotus has invaded and occupies many of the areas formerly dominated by cattail beds. To track the continued development of macrophytes in Par Pond, future surveys through the summer and early fall of 1997, along with the evaluation of satellite data to map the extent of the macrophyte beds of Par Pond, are planned

  7. Containment of Radioactive Waste for Sea Disposal and Fisheries Off the Canadian Pacific Coast; La Mise en Recipients des Dechets Radioactifs en Vue de leur Elimination dans la Mer et la Protection des Pecheries Operant au Large de la Cote Canadienne de l'Ocean Pacifique; 0423 0414 0414 ; Confinamiento de Desechos Radiactivos para su Evacuacion en el Mar, en Relacion con las Pesquerias de la Costa Canadiense del Pacifico

    Energy Technology Data Exchange (ETDEWEB)

    Waldichuk, Michael [Fisheries Research Board of Canada Biological Station, Nanaimo, BC (Canada)

    1960-07-01

    Low-level radioactive waste consists largely of contaminated laboratory trash, larger items of equipment, animal carcasses from biological tracer experiments, active liquids, and some reactor-irradiated materials. A total of 16,288 55-gallon drums of low-level waste has been dumped off the coast of California from 1946 to 1957, inclusive. The major objectives of the criteria for US sea disposal operations have been (1) safety in handling between waste originator and disposal site, and (2) adequate sinking of wastes in the sea. There has been no requirement for integrity of container or contents at depth. Other techniques used or previously suggested for radioactive waste containment, such as canning, adsorption on clay, and integration into glass are described. In order to render a radioactive waste harmless to fish and other aquatic organisms, it must be either (1) isolated from the environment, or (2) dispersed to levels of permissible concentrations. A spherical vault of suitable engineering design, hermetically sealed and able to withstand high pressures, is proposed for low-level and intermediate-level solid waste disposal, as a means of isolating the waste from the environment. Fish may be affected by radioactive waste in their environment through: (1) direct radiation from the disposed radioactive material; (2) ingestion of food organisms containing concentrated radioisotopes; (3) irradiation by water containing radioactive ions or particles; and (4) contamination by bottom materials rich in precipitated radioisotopes. Research necessary before widespread marine disposal of radioactive waste should be permitted is suggested. (author) [French] Les dechets de faible radioactivite sont constitues surtout par des detritus contamines provenant des laboratoires, des accessoires d'assez grande dimension, des carcasses d'animaux ayant servi a des experiences biologiques avec traceurs, des liquides radioactifs et certains materiaux irradies provenant de reacteurs. De

  8. Integrated Box Interrogation System (IBIS) Preliminary Design Study

    CERN Document Server

    Croft, S; Chard-Mj, P; Estop, J R; Martancik, D; Sheila-Melton; Young, B

    2003-01-01

    Canberra Industries has won the tendered solicitation, INEEL/EST-99-00121 for boxed waste Nondestructive Assay Development and Demonstration. Canberra will provide the Integrated Box Interrogation System (IBIS) which is a suite of assay instrumentation and a data reduction system that addresses the measurement needs for Boxed Wastes identified in the solicitation and facilitates the associated experimental program and demonstration of system capability. The IBIS system will consist of the next generation CWAM system, i.e. CWAM II, which is a Scanning Passive/Active Neutron interrogation system which we will call a Box Segmented Neutron Scanner (BSNS), combined with a physically separate Box Segmented Gamma-ray Scanning (BSGS) system. These systems are based on existing hardware designs but will be tailored to the large sample size and enhanced to allow the program to evaluate the following measurement criteria:Characterization and correction for matrix heterogeneity Characterization of non-uniform radio-nucli...

  9. Development of active neutron interrogation techniques at Harwell

    International Nuclear Information System (INIS)

    Armitage, B.H.; Chard, P.M.J.; Packer, T.W.; Swinhoe, M.T.; Syme, D.B.

    1990-01-01

    Active neutron interrogation techniques capable of measuring the fissile content of a range of waste drum sizes and contents have been developed at Harwell. This paper describes measurements which have been made to investigate the behaviour of these assay systems for the difficult case of concreted waste in a heterogeneous matrix. The drums have been measured using a Cf shuffler and a differential die-away system, with supporting information obtained from a segmented gamma-scanner. Good correspondence has been observed between the two different neutron interrogation techniques. It was concluded that the measurement of highly heterogeneous wastes is likely to be more effective if calibration can be undertaken with representative artificial matrices. Further measurement and analysis remains to be undertaken

  10. Noncontact power/interrogation system for smart structures

    Science.gov (United States)

    Spillman, William B., Jr.; Durkee, S.

    1994-05-01

    The field of smart structures has been largely driven by the development of new high performance designed materials. Use of these materials has been generally limited due to the fact that they have not been in use long enough for statistical data bases to be developed on their failure modes. Real time health monitoring is therefore required for the benefits of structures using these materials to be realized. In this paper a non-contact method of powering and interrogating embedded electronic and opto-electronic systems is described. The technique utilizes inductive coupling between external and embedded coils etched on thin electronic circuit cards. The technique can be utilized to interrogate embedded sensors and to provide > 250 mW for embedded electronics. The system has been successfully demonstrated with a number of composite and plastic materials through material thicknesses up to 1 cm. An analytical description of the system is provided along with experimental results.

  11. The development of enabling technologies for producing active interrogation beams.

    Science.gov (United States)

    Kwan, Thomas J T; Morgado, Richard E; Wang, Tai-Sen F; Vodolaga, B; Terekhin, V; Onischenko, L M; Vorozhtsov, S B; Samsonov, E V; Vorozhtsov, A S; Alenitsky, Yu G; Perpelkin, E E; Glazov, A A; Novikov, D L; Parkhomchuk, V; Reva, V; Vostrikov, V; Mashinin, V A; Fedotov, S N; Minayev, S A

    2010-10-01

    A U.S./Russian collaboration of accelerator scientists was directed to the development of high averaged-current (∼1 mA) and high-quality (emittance ∼15 πmm mrad; energy spread ∼0.1%) 1.75 MeV proton beams to produce active interrogation beams that could be applied to counterterrorism. Several accelerator technologies were investigated. These included an electrostatic tandem accelerator of novel design, a compact cyclotron, and a storage ring with energy compensation and electron cooling. Production targets capable of withstanding the beam power levels were designed, fabricated, and tested. The cyclotron/storage-ring system was theoretically studied and computationally designed, and the electrostatic vacuum tandem accelerator at BINP was demonstrated for its potential in active interrogation of explosives and special nuclear materials.

  12. Fiber Bragg grating sensor interrogators on chip: challenges and opportunities

    Science.gov (United States)

    Marin, Yisbel; Nannipieri, Tiziano; Oton, Claudio J.; Di Pasquale, Fabrizio

    2017-04-01

    In this paper we present an overview of the current efforts towards integration of Fiber Bragg Grating (FBG) sensor interrogators. Different photonic integration platforms will be discussed, including monolithic planar lightwave circuit technology, silicon on insulator (SOI), indium phosphide (InP) and gallium arsenide (GaAs) material platforms. Also various possible techniques for wavelength metering and methods for FBG multiplexing will be discussed and compared in terms of resolution, dynamic performance, multiplexing capabilities and reliability. The use of linear filters, array waveguide gratings (AWG) as multiple linear filters and AWG based centroid signal processing techniques will be addressed as well as interrogation techniques based on tunable micro-ring resonators and Mach-Zehnder interferometers (MZI) for phase sensitive detection. The paper will also discuss the challenges and perspectives of photonic integration to address the increasing requirements of several industrial applications.

  13. Interrogation of Detainees: Requirements of the Detainee Treatment Act

    Science.gov (United States)

    2009-08-26

    providing legal protections and assistance to U.S. personnel subjected to legal action on account of their involvement in the authorized interrogation of...types of actions prohibited by the U.S. Constitution. There is some legal dispute as to whether CAT Article 16, as read in light of U.S. reservations... unconstitutionally harsh than it would use to assess whether those same techniques were unconstitutional if employed against an enemy combatant in a war zone

  14. Educing Information - Interrogation: Science and Art, Foundations for the Future

    Science.gov (United States)

    2006-12-01

    imprisonment as an integral component of the inquisitor’s interrogation strategy…. [C]oupled if necessary, with hunger , shackles, and torture…[it...computer science with a concentration in machine intelligence and cognition, and minors in neuropsychology and developmental psychology, from The George...a solid theoretical base, then a signifi cant research investment into the underlying neuropsychological mechanisms of deception must be made before

  15. Microwave Wire Interrogation Method Mapping Pressure under High Temperatures

    Directory of Open Access Journals (Sweden)

    Xiaoyong Chen

    2017-12-01

    Full Text Available It is widely accepted that wireless reading for in-situ mapping of pressure under high-temperature environments is the most feasible method, because it is not subject to frequent heterogeneous jointing failures and electrical conduction deteriorating, or even disappearing, under heat load. However, in this article, we successfully demonstrate an in-situ pressure sensor with wire interrogation for high-temperature applications. In this proof-of-concept study of the pressure sensor, we used a microwave resonator as a pressure-sensing component and a microwave transmission line as a pressure characteristic interrogation tunnel. In the sensor, the line and resonator are processed into a monolith, avoiding a heterogeneous jointing failure; further, microwave signal transmission does not depend on electrical conduction, and consequently, the sensor does not suffer from the heat load. We achieve pressure monitoring under 400 °C when employing the sensor simultaneously. Our sensor avoids restrictions that exist in wireless pressure interrogations, such as environmental noise and interference, signal leakage and security, low transfer efficiency, and so on.

  16. Fissile mass estimation by pulsed neutron source interrogation

    Energy Technology Data Exchange (ETDEWEB)

    Israelashvili, I., E-mail: israelashvili@gmail.com [Nuclear Research Center of the Negev, P.O.B 9001, Beer Sheva 84190 (Israel); Dubi, C.; Ettedgui, H.; Ocherashvili, A. [Nuclear Research Center of the Negev, P.O.B 9001, Beer Sheva 84190 (Israel); Pedersen, B. [Nuclear Security Unit, Institute for Transuranium Elements, Joint Research Centre, Via E. Fermi, 2749, 21027 Ispra (Italy); Beck, A. [Nuclear Research Center of the Negev, P.O.B 9001, Beer Sheva 84190 (Israel); Roesgen, E.; Crochmore, J.M. [Nuclear Security Unit, Institute for Transuranium Elements, Joint Research Centre, Via E. Fermi, 2749, 21027 Ispra (Italy); Ridnik, T.; Yaar, I. [Nuclear Research Center of the Negev, P.O.B 9001, Beer Sheva 84190 (Israel)

    2015-06-11

    Passive methods for detecting correlated neutrons from spontaneous fissions (e.g. multiplicity and SVM) are widely used for fissile mass estimations. These methods can be used for fissile materials that emit a significant amount of fission neutrons (like plutonium). Active interrogation, in which fissions are induced in the tested material by an external continuous source or by a pulsed neutron source, has the potential advantages of fast measurement, alongside independence of the spontaneous fissions of the tested fissile material, thus enabling uranium measurement. Until recently, using the multiplicity method, for uranium mass estimation, was possible only for active interrogation made with continues neutron source. Pulsed active neutron interrogation measurements were analyzed with techniques, e.g. differential die away analysis (DDA), which ignore or implicitly include the multiplicity effect (self-induced fission chains). Recently, both, the multiplicity and the SVM techniques, were theoretically extended for analyzing active fissile mass measurements, made by a pulsed neutron source. In this study the SVM technique for pulsed neutron source is experimentally examined, for the first time. The measurements were conducted at the PUNITA facility of the Joint Research Centre in Ispra, Italy. First promising results, of mass estimation by the SVM technique using a pulsed neutron source, are presented.

  17. On Functional Potential of Interrogative Structures in Academic Linguistic Discourse

    Directory of Open Access Journals (Sweden)

    Sergey Trofimovich Nefedov

    2015-11-01

    Full Text Available The paper deals with the language of scientific communication in the field of linguistics, namely, with the functional potential of the interrogative structures in the form of direct and embedded questions. From a pragmatic perspective the interrogative structures does not seem to be compatible with the contexts of scientific interaction: scientists do not ask for information, but they offer their own solutions for the problem situations. This is reflected in the extremely low frequency of questions in academic research articles and monographs. Their text frequency works out a little over 2 % of the total number of the text predications and that of direct questions is about 1 %. Therefore, their place in verbalization of scientific knowledge in linguistics is metaphorically characterized in this article as «interrogative prohibition» by analogy with the «prohibitions» of Harald Weinrich who introduced several notions point to rarely used linguistic units: «prohibition of authorization» – das «Ich-Verbot», «narrative prohibition» – das «Erzähl-Verbot»; «prohibition of metaphors»– das «MetaphernVerbot». In its turn, low frequency makes the analyzed structures an effective tool to formulate the discussed problems, enables further argumentation, integrate the current text into overall linguistic discourse, control the development of the argumentation in scientific text and finally to draw the recipient's attention to a crucial or unexpected argument.

  18. Monte Carlo Simulation for LINAC Standoff Interrogation of Nuclear Material

    International Nuclear Information System (INIS)

    Clarke, Shaun D.; Flaska, Marek; Miller, Thomas Martin; Protopopescu, Vladimir A.; Pozzi, Sara A.

    2007-01-01

    The development of new techniques for the interrogation of shielded nuclear materials relies on the use of Monte Carlo codes to accurately simulate the entire system, including the interrogation source, the fissile target and the detection environment. The objective of this modeling effort is to develop analysis tools and methods-based on a relevant scenario-which may be applied to the design of future systems for active interrogation at a standoff. For the specific scenario considered here, the analysis will focus on providing the information needed to determine the type and optimum position of the detectors. This report describes the results of simulations for a detection system employing gamma rays to interrogate fissile and nonfissile targets. The simulations were performed using specialized versions of the codes MCNPX and MCNP-PoliMi. Both prompt neutron and gamma ray and delayed neutron fluxes have been mapped in three dimensions. The time dependence of the prompt neutrons in the system has also been characterized For this particular scenario, the flux maps generated with the Monte Carlo model indicate that the detectors should be placed approximately 50 cm behind the exit of the accelerator, 40 cm away from the vehicle, and 150 cm above the ground. This position minimizes the number of neutrons coming from the accelerator structure and also receives the maximum flux of prompt neutrons coming from the source. The lead shielding around the accelerator minimizes the gamma-ray background from the accelerator in this area. The number of delayed neutrons emitted from the target is approximately seven orders of magnitude less than the prompt neutrons emitted from the system. Therefore, in order to possibly detect the delayed neutrons, the detectors should be active only after all prompt neutrons have scattered out of the system. Preliminary results have shown this time to be greater than 5 ?s after the accelerator pulse. This type of system is illustrative of a

  19. Repérer des sites similaires à une recherche par Google

    OpenAIRE

    Ginouvès, Véronique

    2006-01-01

    Repérer des sites similaires à une recherche par Google Afficher graphiquement les liens d’un site avec d’autres sites similaires TouchGraph GoogleBrowser crée des agrégations de sites à partir de l’interrogation de Google. Vous visualisez ainsi des nébuleuses de sites à l’intérieur desquelles vous pouvez naviguer facilement, en sautant d'un groupe à l'autre afin de voir les nuages autour de sujets ou de communautés de sujets. Cet outil a été développé par Alex Shapiro, à partir de la version...

  20. Vote par sondage uniforme incorruptible

    OpenAIRE

    Blanchard , Nicolas

    2016-01-01

    International audience; Introduit en 2012 par David Chaum, le vote par sondage uniforme (random-sample voting) est un protocole de vote basé sur un choix d'une sous-population représentative , permettant de limiter les coûts tout en ayant de nombreux avantages, principalement lorsqu'il est couplé a d'autres techniques comme ThreeBallot. Nous analysons un problème de corruptibilité potentielle où les votants peuvent vendre leur vote au plus offrant et proposons une variation du protocole reméd...

  1. Device for recovering radioactive waste; Dispositif de recuperation d'effluents radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    Mas, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-07-01

    The previous system which consisted in the use of metallic reservoirs placed in a concrete-lined pit gave rise to certain incidents due to corrosion or overflowing followed by contamination with serious consequences. The new system presented consists essentially of a standard 3 m{sup 3} reservoir of stainless steel which is fixed in a concrete-lined well, is tubed with stainless steel. Each reservoir has a standard lid on which are placed all the accessory devices, themselves standardized. The new reservoirs offer thus a great degree of security, and are interchangeable; the wells are easy to decontaminate and it is possible to work in a well without any danger of the personnel being irradiated by neighbouring reservoirs. (author) [French] L'ancien systeme de cuves metalliques disposees dans une fosse betonnee a donne lieu a des incidents par corrosion ou debordements suivis de contamination ayant de grosses consequences. Le nouveau systeme presente comporte essentiellement une cuve standard de 7 m{sup 3} en acier inoxydable mise en place et ancree dans un puits betonne et cuvele en acier inoxydable. Chaque cuve comporte un couvercle standard sur lequel sont rassembles tous les dispositifs annexes standardises eux aussi. Les nouvelles cuves sont donc sures, interchangeables, les puits sont faciles a decontaminer et le travail dans un puits est possible sans crainte d'irradiation du personnel par les cuves voisines. (auteur)

  2. System design considerations for fast-neutron interrogation systems

    International Nuclear Information System (INIS)

    Micklich, B.J.; Curry, B.P.; Fink, C.L.; Smith, D.L.; Yule, T.J.

    1993-01-01

    Nonintrusive interrogation techniques that employ fast neutrons are of interest because of their sensitivity to light elements such as carbon, nitrogen, and oxygen. The primary requirement of a fast-neutron inspection system is to determine the value of atomic densities, or their ratios, over a volumetric grid superimposed on the object being interrogated. There are a wide variety of fast-neutron techniques that can provide this information. The differences between the various nuclear systems can be considered in light of the trade-offs relative to the performance requirements for each system's components. Given a set of performance criteria, the operational requirements of the proposed nuclear systems may also differ. For instance, resolution standards will drive scanning times and tomographic requirements, both of which vary for the different approaches. We are modelling a number of the fast-neutron interrogation techniques currently under consideration, to include Fast Neutron Transmission Spectroscopy (FNTS), Pulsed Fast Neutron Analysis (PFNA), and its variant, 14-MeV Associated Particle Imaging (API). The goals of this effort are to determine the component requirements for each technique, identify trade-offs that system performance standards impose upon those component requirements, and assess the relative advantages and disadvantages of the different approaches. In determining the component requirements, we will consider how they are driven by system performance standards, such as image resolution, scanning time, and statistical uncertainty. In considering the trade-offs between system components, we concentrate primarily on those which are common to all approaches, for example: source characteristics versus detector array requirements. We will then use the analysis to propose some figures-of-merit that enable performance comparisons between the various fast-neutron systems under consideration. The status of this ongoing effort is presented

  3. Metabolic interrogation as a tool to optimize chemotherapeutic regimens.

    Science.gov (United States)

    Sandulache, Vlad C; Chen, Yunyun; Feng, Lei; William, William N; Skinner, Heath D; Myers, Jeffrey N; Meyn, Raymond E; Li, Jinzhong; Mijiti, Ainiwaer; Bankson, James A; Fuller, Clifton D; Konopleva, Marina Y; Lai, Stephen Y

    2017-03-14

    Platinum-based (Pt) chemotherapy is broadly utilized in the treatment of cancer. Development of more effective, personalized treatment strategies require identification of novel biomarkers of treatment response. Since Pt compounds are inactivated through cellular metabolic activity, we hypothesized that metabolic interrogation can predict the effectiveness of Pt chemotherapy in a pre-clinical model of head and neck squamous cell carcinoma (HNSCC).We tested the effects of cisplatin (CDDP) and carboplatin (CBP) on DNA damage, activation of cellular death cascades and tumor cell metabolism, specifically lactate production. Pt compounds induced an acute dose-dependent, transient drop in lactate generation in vitro, which correlated with effects on DNA damage and cell death. Neutralization of free radical stress abrogated these effects. The magnitude of this effect on lactate production correlated with the differential sensitivity of HNSCC cells to Pt compounds (CDDP vs CBP) and p53-driven Pt chemotherapy resistance. Using dual flank xenograft tumors, we demonstrated that Pt-driven effects on lactate levels correlate with effects on tumor growth delay in a dose-dependent manner and that lactate levels can define the temporal profile of Pt chemotherapy-induced metabolic stress. Lactate interrogation also predicted doxorubicin effects on cell death in both solid tumor (HNSCC) and acute myelogenous leukemia (AML) cell lines.Real-time metabolic interrogation of acute changes in cell and tumor lactate levels reflects chemotherapy effects on DNA damage, cell death and tumor growth delay. We have identified a real-time biomarker of chemotherapy effectiveness which can be used to develop adaptive, iterative and personalized treatment regimens against a variety of solid and hematopoietic malignancies.

  4. Fissile materials in solution concentration measured by active neutron interrogation

    International Nuclear Information System (INIS)

    Romeyer Dherbey, J.; Passard, Ch.; Cloue, J.; Bignan, G.

    1993-01-01

    The use of the active neutron interrogation to measure the concentration of plutonium contained in flow solutions is particularly interesting for fuel reprocessing plants. Indeed, this method gives a signal which is in a direct relation with the fissile materials concentration. Moreover, it is less sensitive to the gamma dose rate than the other nondestructive methods. Two measure methods have been evolved in CEA. Their principles are given into details in this work. The first one consists to detect fission delayed neutrons induced by a 252 Cf source. In the second one fission prompt neutrons induced by a neutron generator of 14 MeV are detected. (O.M.)

  5. Lawfulness of Interrogation Techniques under the Geneva Conventions

    Science.gov (United States)

    2004-09-08

    on Interrogation Process (June 22, 2004), available at [http://www.defenselink.mil/releases/2004/ nr20040622-0930.html]. 2 See A. J . BARKER, PRISONERS...U.S. ARMY JUDGE ADVOCATE SCHOOL, LAW OF WAR WORKSHOP DESKBOOK 83 (CDR Brian J . Bill, ed. 2000) [hereinafter “ L O W D E S K B O O K ” ] , a v a i l...or purpose behind the conduct is a prohibited purpose. See Prosecutor v. Kunarac, Kovac and Vukovic , Nos. IT-96-23 and IT-96-23/11, para. 486 (ITCY

  6. Fiber-MZI-based FBG sensor interrogation: comparative study with a CCD spectrometer.

    Science.gov (United States)

    Das, Bhargab; Chandra, Vikash

    2016-10-10

    We present an experimental comparative study of the two most commonly used fiber Bragg grating (FBG) sensor interrogation techniques: a charge-coupled device (CCD) spectrometer and a fiber Mach-Zehnder interferometer (F-MZI). Although the interferometric interrogation technique is historically known to offer the highest sensitivity measurements, very little information exists regarding how it compares with the current commercially available spectral-characteristics-based interrogation systems. It is experimentally established here that the performance of a modern-day CCD spectrometer interrogator is very close to a F-MZI interrogator with the capability of measuring Bragg wavelength shifts with sub-picometer-level accuracy. The results presented in this research study can further be used as a guideline for choosing between the two FBG sensor interrogator types for small-amplitude dynamic perturbation measurements down to nano-level strain.

  7. Half-life distribution table of radioactive nuclei; Table de distribution des periodes des noyaux radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    Gugenberger, P [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires

    1954-07-01

    This table allows to identify an element if its period is known. Data for this table were taken from the half-life values adopted by Hollander, PERLMAN and SEABORG (Rev. mod. Phys., 1953, 22 number 2). Moreover for each nucleus, the mass number, the charge number and the type of decay are given in the table. (author) [French] Cette table permet l'identification d'un element dont la periode est connue. Elle a ete etablie en utilisant les valeurs des periodes donnees par HOLLANDER, PERLMAN et SEABORG dans Rev. mod. Phys., 1953, 25 numero 2. On y trouve en outre, pour chaque nuclide, les caracteristiques suivantes: Z, A, modes de desintegration. (auteur)

  8. Half-life distribution table of radioactive nuclei; Table de distribution des periodes des noyaux radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    Gugenberger, P. [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires

    1954-07-01

    This table allows to identify an element if its period is known. Data for this table were taken from the half-life values adopted by Hollander, PERLMAN and SEABORG (Rev. mod. Phys., 1953, 22 number 2). Moreover for each nucleus, the mass number, the charge number and the type of decay are given in the table. (author) [French] Cette table permet l'identification d'un element dont la periode est connue. Elle a ete etablie en utilisant les valeurs des periodes donnees par HOLLANDER, PERLMAN et SEABORG dans Rev. mod. Phys., 1953, 25 numero 2. On y trouve en outre, pour chaque nuclide, les caracteristiques suivantes: Z, A, modes de desintegration. (auteur)

  9. Real time interrogation technique for fiber Bragg grating enhanced fiber loop ringdown sensors array.

    Science.gov (United States)

    Zhang, Yunlong; Li, Ruoming; Shi, Yuechun; Zhang, Jintao; Chen, Xiangfei; Liu, Shengchun

    2015-06-01

    A novel fiber Bragg grating aided fiber loop ringdown (FLRD) sensor array and the wavelength-time multiplexing based interrogation technique for the FLRD sensors array are proposed. The interrogation frequency of the system is formulated and the interrelationships among the parameters of the system are analyzed. To validate the performance of the proposed system, a five elements array is experimentally demonstrated, and the system shows the capability of real time monitoring every FLRD element with interrogation frequency of 125.5 Hz.

  10. Police interviewing and interrogation of juvenile suspects: a descriptive examination of actual cases.

    Science.gov (United States)

    Cleary, Hayley M D

    2014-06-01

    Although empirical attention to police interrogation has gained traction in recent years, comparatively few studies have examined interrogation of juvenile suspects, and virtually none have examined actual interrogations. Despite a growing literature on youths' interrogation-related capacities, we still know very little about what actually transpires when police question youth. The present study examines electronically recorded police interviews with juveniles to describe the characteristics, processes, and outcomes that occur in actual juvenile interrogations, including interview duration, individuals present, and confessions. Fifty-seven electronic recordings from 17 police departments were analyzed using observational research software. The median juvenile interrogation lasted 46 min, though the range was extensive (6 min to nearly 5 hr). Youth frequently submitted to questioning without a parent or advocate present, and disruptions to the interview process were common. Interrogation outcomes varied and included full confessions, partially incriminating admissions, and denials of guilt. Results from this study provide context for interrogation research using other methods and suggest that youth may frequently consent to interrogation in the absence of important legal protections.

  11. Determination of Interrogating Frequencies to Maximize Electromagnetic Backscatter from Objects with Material Coatings

    National Research Council Canada - National Science Library

    Banks, H. T; Ito, K; Toivanen, J

    2005-01-01

    .... Based on the radar cross section and a reflection coefficient, optimization problems are formulated for evaders and interrogators leading to optimal material parameters for the coating and optimal...

  12. Remotely Interrogated Passive Polarizing Dosimeter (RIPPeD).

    Energy Technology Data Exchange (ETDEWEB)

    Kemme, Shanalyn A.; Buller, Daniel L.; Dirk, Shawn M.; Boye, Robert R.; Samora, Sally; Washburn, Cody M.; Wheeler, David Roger

    2008-09-01

    Conductive polymers have become an extremely useful class of materials for many optical applications. We have developed an electrochemical growth method for depositing highly conductive ({approx}100 S/cm) polypyrrole. Additionally, we have adapted advanced fabrication methods for use with the polypyrrole resulting in gratings with submicron features. This conductive polymer micro-wire grid provides an optical polarizer with unique properties. When the polymer is exposed to ionizing radiation, its conductivity is affected and the polarization properties of the device, specifically the extinction ratio, change in a corresponding manner. This change in polarization properties can be determined by optically interrogating the device, possibly from a remote location. The result is a passive radiation-sensitive sensor with very low optical visibility. The ability to interrogate the device from a safe standoff distance provides a device useful in potentially dangerous environments. Also, the passive nature of the device make it applicable in applications where external power is not available. We will review the polymer deposition, fabrication methods and device design and modeling. The characterization of the polymer's sensitivity to ionizing radiation and optical testing of infrared polarizers before and after irradiation will also be presented. These experimental results will highlight the usefulness of the conductive infrared polarizer to many security and monitoring applications.

  13. Performance of an optical identification and interrogation system

    Science.gov (United States)

    Venugopalan, A.; Ghosh, A. K.; Verma, P.; Cheng, S.

    2008-04-01

    A free space optics based identification and interrogation system has been designed. The applications of the proposed system lie primarily in areas which require a secure means of mutual identification and information exchange between optical readers and tags. Conventional RFIDs raise issues regarding security threats, electromagnetic interference and health safety. The security of RF-ID chips is low due to the wide spatial spread of radio waves. Malicious nodes can read data being transmitted on the network, if they are in the receiving range. The proposed system provides an alternative which utilizes the narrow paraxial beams of lasers and an RSA-based authentication scheme. These provide enhanced security to communication between a tag and the base station or reader. The optical reader can also perform remote identification and the tag can be read from a far off distance, given line of sight. The free space optical identification and interrogation system can be used for inventory management, security systems at airports, port security, communication with high security systems, etc. to name a few. The proposed system was implemented with low-cost, off-the-shelf components and its performance in terms of throughput and bit error rate has been measured and analyzed. The range of operation with a bit-error-rate lower than 10-9 was measured to be about 4.5 m. The security of the system is based on the strengths of the RSA encryption scheme implemented using more than 1024 bits.

  14. Ion-induced gammas for photofission interrogation of HEU.

    Energy Technology Data Exchange (ETDEWEB)

    Doyle, Barney Lee (Sandia National Laboratories, Albuquerque, NM); Antolak, Arlyn J.; Morse, Daniel H.; Provencio, Paula Polyak (Sandia National Laboratories, Albuquerque, NM)

    2006-03-01

    High-energy photons and neutrons can be used to actively interrogate for heavily shielded special nuclear material (SNM), such as HEU (highly enriched uranium), by detecting prompt and/or delayed induced fission signatures. In this work, we explore the underlying physics for a new type of photon source that generates high fluxes of mono-energetic gamma-rays from low-energy (<500 keV) proton-induced nuclear reactions. The characteristic energies (4- to 18-MeV) of the gamma-rays coincide with the peak of the photonuclear cross section. The source could be designed to produce gamma-rays of certain selected energies, thereby improving the probability of detecting shielded HEU or providing a capability to determine enrichment inside sealed containers. The fundamental physics of such an interrogation source were studied in this LDRD through scaled ion accelerator experiments and radiation transport modeling. The data were used to assess gamma and neutron yields, background, and photofission-induced signal levels from several (p,{gamma}) target materials under consideration.

  15. Integrated Box Interrogation System (IBIS) Preliminary Design Study

    Energy Technology Data Exchange (ETDEWEB)

    DR. Stephen Croft; Mr. David Martancik; Dr. Brian Young; Dr. Patrick MJ Chard; Dr. Robert J Estop; Sheila Melton; Gaetano J. Arnone

    2003-01-13

    Canberra Industries has won the tendered solicitation, INEEL/EST-99-00121 for boxed waste Nondestructive Assay Development and Demonstration. Canberra will provide the Integrated Box Interrogation System (IBIS) which is a suite of assay instrumentation and a data reduction system that addresses the measurement needs for Boxed Wastes identified in the solicitation and facilitates the associated experimental program and demonstration of system capability. The IBIS system will consist of the next generation CWAM system, i.e. CWAM II, which is a Scanning Passive/Active Neutron interrogation system which we will call a Box Segmented Neutron Scanner (BSNS), combined with a physically separate Box Segmented Gamma-ray Scanning (BSGS) system. These systems are based on existing hardware designs but will be tailored to the large sample size and enhanced to allow the program to evaluate the following measurement criteria:Characterization and correction for matrix heterogeneity Characterization of non-uniform radio-nuclide and isotopic compositions Assay of high density matrices (both high-Z and high moderator contents)Correction for radioactive material physical form - such as self shielding or multiplication effects due to large accumulations of radioactive materials.Calibration with a minimal set of reference standards and representative matrices.THis document summarizes the conceptual design parameters of the IBIS and indicates areas key to the success of the project where development is to be centered. The work presented here is a collaborative effort between scientific staff within Canberra and within the NIS-6 group at LANL.

  16. Integrated Box Interrogation System (IBIS) Preliminary Design Study

    International Nuclear Information System (INIS)

    Croft, Stephen; Martancik, David; Young, Brian; Chard MJ, Patrick; Estop J, Robert; Sheila Melton; Arnone, Gaetano J.

    2003-01-01

    Canberra Industries has won the tendered solicitation, INEEL/EST-99-00121 for boxed waste Nondestructive Assay Development and Demonstration. Canberra will provide the Integrated Box Interrogation System (IBIS) which is a suite of assay instrumentation and a data reduction system that addresses the measurement needs for Boxed Wastes identified in the solicitation and facilitates the associated experimental program and demonstration of system capability. The IBIS system will consist of the next generation CWAM system, i.e. CWAM II, which is a Scanning Passive/Active Neutron interrogation system which we will call a Box Segmented Neutron Scanner (BSNS), combined with a physically separate Box Segmented Gamma-ray Scanning (BSGS) system. These systems are based on existing hardware designs but will be tailored to the large sample size and enhanced to allow the program to evaluate the following measurement criteria:Characterization and correction for matrix heterogeneity Characterization of non-uniform radio-nuclide and isotopic compositions Assay of high density matrices (both high-Z and high moderator contents)Correction for radioactive material physical form - such as self shielding or multiplication effects due to large accumulations of radioactive materials.Calibration with a minimal set of reference standards and representative matrices.THis document summarizes the conceptual design parameters of the IBIS and indicates areas key to the success of the project where development is to be centered. The work presented here is a collaborative effort between scientific staff within Canberra and within the NIS-6 group at LANL

  17. Remotely Interrogated Passive Polarizing Dosimeter (RIPPeD)

    International Nuclear Information System (INIS)

    Kemme, Shanalyn A.; Buller, Daniel L.; Dirk, Shawn M.; Boye, Robert R.; Samora, Sally; Washburn, Cody M.; Wheeler, David Roger

    2008-01-01

    Conductive polymers have become an extremely useful class of materials for many optical applications. We have developed an electrochemical growth method for depositing highly conductive (∼100 S/cm) polypyrrole. Additionally, we have adapted advanced fabrication methods for use with the polypyrrole resulting in gratings with submicron features. This conductive polymer micro-wire grid provides an optical polarizer with unique properties. When the polymer is exposed to ionizing radiation, its conductivity is affected and the polarization properties of the device, specifically the extinction ratio, change in a corresponding manner. This change in polarization properties can be determined by optically interrogating the device, possibly from a remote location. The result is a passive radiation-sensitive sensor with very low optical visibility. The ability to interrogate the device from a safe standoff distance provides a device useful in potentially dangerous environments. Also, the passive nature of the device make it applicable in applications where external power is not available. We will review the polymer deposition, fabrication methods and device design and modeling. The characterization of the polymer's sensitivity to ionizing radiation and optical testing of infrared polarizers before and after irradiation will also be presented. These experimental results will highlight the usefulness of the conductive infrared polarizer to many security and monitoring applications

  18. The captive brain: torture and the neuroscience of humane interrogation.

    Science.gov (United States)

    O'Mara, S

    2018-02-01

    Despite it being abhorrent and illegal, torture is sometimes employed for information gathering. However, the extreme stressors employed during torture force the brain away from the relatively narrow, adaptive range of function it operates within. Torture degrades signal-to-noise ratios of information yield and increases false positive discovery rates. As a discovery methodology, torture fails basic tests of veridical, reliable and replicable information discovery. Torture fails during interrogation because it is an assault on our core integrated, social, psychological and neural functioning. There is a need for a profound cultural shift regarding torture, recognizing that torture impairs, rather than facilitates, investigations and truth-finding. Rising to this challenge will increase operational effectiveness, eliminate prisoner abuse and torment, and aid veridical and actionable information gathering. Policy regarding prisoner and detainee interrogation need to be refocused as a behavioural and brain sciences problem, and not simply treated as a legal, ethical or philosophical problem. Getting the science, ethics and practice in line is a challenge, but it can and should be done.

  19. Optical Stabilization of a Microwave Oscillator for Fountain Clock Interrogation.

    Science.gov (United States)

    Lipphardt, Burghard; Gerginov, Vladislav; Weyers, Stefan

    2017-04-01

    We describe an optical frequency stabilization scheme of a microwave oscillator that is used for the interrogation of primary cesium fountain clocks. Because of its superior phase noise properties, this scheme, which is based on an ultrastable laser and a femtosecond laser frequency comb, overcomes the frequency instability limitations of fountain clocks given by the previously utilized quartz-oscillator-based frequency synthesis. The presented scheme combines the transfer of the short-term frequency instability of an optical cavity and the long-term frequency instability of a hydrogen maser to the microwave oscillator and is designed to provide continuous long-term operation for extended measurement periods of several weeks. The utilization of the twofold stabilization scheme on the one hand ensures the referencing of the fountain frequency to the hydrogen maser frequency and on the other hand results in a phase noise level of the fountain interrogation signal, which enables fountain frequency instabilities at the 2.5 ×10 -14 (τ/s) -1/2 level that are quantum projection noise limited.

  20. Age and interviewer behavior as predictors of interrogative suggestibility.

    Science.gov (United States)

    Dukala, Karolina; Polczyk, Romuald

    2014-05-01

    The main objective was to explore the influence of interviewer behavior-abrupt versus friendly-and the age of participants on interrogative suggestibility. The study involved 42 young adults and 50 elderly participants. The Gudjonsson Suggestibility Scale 2 was used. Data analysis involved a 2-factor between-subjects design (interviewer behavior × age) and mediation analysis. The scores of elderly participants were significantly lower than younger adults on memory indices and significantly higher on some suggestibility indexes. Some suggestibility indices in the abrupt experimental condition were higher than those in the friendly experimental condition. Elderly participants who were interviewed under the abrupt condition were more likely to change their answers after receiving negative feedback than younger adults. Memory quality was a mediator of the relationship between age and the tendency to yield to suggestive questions. Self-appraisal of memory was a mediator between both age and interviewer behavior and the tendency to change answers after negative feedback. Mechanisms of the relationship between age, interviewer behavior, and suggestibility are discussed on the basis of the mediational analyses. The findings suggest that a friendly manner should be adopted when interrogating witnesses.

  1. Par Pond Fish, Water, and Sediment Chemistry

    Energy Technology Data Exchange (ETDEWEB)

    Paller, M.H. [Westinghouse Savannah River Company, AIKEN, SC (United States); Wike, L.D.

    1996-06-01

    The objectives of this report are to describe the Par Pond fish community and the impact of the drawdown and refill on the community, describe contaminant levels in Par Pond fish, sediments, and water and indicate how contaminant concentrations and distributions were affected by the drawdown and refill, and predict possible effects of future water level fluctuations in Par Pond.

  2. Par Pond Fish, Water, and Sediment Chemistry

    International Nuclear Information System (INIS)

    Paller, M.H.; Wike, L.D.

    1996-06-01

    The objectives of this report are to describe the Par Pond fish community and the impact of the drawdown and refill on the community, describe contaminant levels in Par Pond fish, sediments, and water and indicate how contaminant concentrations and distributions were affected by the drawdown and refill, and predict possible effects of future water level fluctuations in Par Pond

  3. Sorption Regularities in Behaviour of Fission-Product Elements during Filtration of their Solutions through Ground; Lois de l'Absorption des Elements Radioactifs Lors du Filtrage des Solutions a Travers les Terrains; 0417 0410 041a 041e 041d 0414 ; Leyes de la Absorcion de los Elementos Radiactivos Cuando se Filtran Soluciones a Traves de las Formaciones Geologicas

    Energy Technology Data Exchange (ETDEWEB)

    Spitsyn, V. I.; Balukova, V. D.; Gromov, V. V.; Zakharov, S. I.; Zhagin, B. P.; Spiridonov, F. M.

    1960-07-01

    la nature. Des que la filtration est devenue constante, on a commence a ajouter a la solution des elements radioactifs ; le processus a dure quatre mois. Des forages consecutifs ont permis de recueillir, a des profondeurs differentes, des echantillons du sol qui ont ete analyses en vue de determiner leur teneur en radioelements. Il a ete constate que la diffusion des isotopes radioactifs atteignait une profondeur d'au moins dix metres, et qu'il existait deux zones nettement determinees ou la radioactivite du sol etait plus faible : l'une a la surface du terrain et l'autre au fond atteint par la solution filtree. On a procede en outre a une etude separee de l'absorption du radio-strontium par des absorbants naturels, principalement par les mineraux purs largement repandus dans les diverses terrains. La presence de certaines quantites, meme petites, d'ions de calcium reduit sensiblement le taux d'absorption du radiostrontium. Cependant, en raison de leur composition - toutes les autres conditions etant egales - certaines substances peuvent absorber le strontium en quantites plus elevees que le calcium. La verification sur place de l'absorption et de la migration du radiostrontium a montre que la filtration des solutions radioactives peut se presenter sous deux formes differentes. Elle prend la premiere lorsque les solutions sont deversees dans des terrains sans a l'action du flux d'eau. Le radiostrontium est alors retenu par les terrains. La deuxieme se presente quand les elements radioactifs penetrent directement dans les couches aquiferes. Dans ce cas le radiostrontium est entraine par les courants souterrains et penetre egalement dans les terrains ou sa migration s'accompagne du processus d'absorption et de desorption. (author) [Spanish] Provocando un proceso de filtracion se ha podido estudiar la absorcion de los elementos radiactivos en la naturaleza. En cuanto se inicio la filtracion se anadieron elementos radicativos a la solucion; el proceso se prolongo durante

  4. Problems presented by the filtration and sampling of aerosols in the atomic energy programme; Problemes poses par la filtration et le prelevement des aerosols dans le cadre de l'energie atomique

    Energy Technology Data Exchange (ETDEWEB)

    Cochinal, R [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    The maximum permissible limits for radioactive aerosols are much lower than those for aerosols encountered in the non-nuclear industries. These limits depend on numerous factors such as: nature of the radiation, half-life, etc. The radioactive aerosols can be prepared by various methods. The filtering of the air in high activity laboratories or in plutonium treatment factories necessitates an installation consisting of: - aspiration filters, - extraction filters of very high efficiency (those used for {alpha} emitter cells: designed to be replaced without incurring contamination risks; those used for {gamma} emitter cells: designed to be replaced by remote control). The filtering in nuclear reactors is also effectuated by filter papers: - the G1 reactor with open circuit: the air coolant is entirely filtered at the entry and on leaving; - the G2, G3 and EDF1 reactors with closed circuits: filtering under pressure of a small portion of the coolant gas. (author) [French] Les limites maxima permises des aerosols radioactifs sont beaucoup plus faibles que celles des aerosols rencontres dans l'industrie classique. Elles dependent de nombreux facteurs tel que: nature du rayonnement, periode radioactive, etc... La formation des aerosols radioactifs est de nature diverse. La filtration des laboratoires de haute activite, ou d'usines d'elaboration de plutonium conduit a des types d'installations comportant: - des filtres d'aspiration; - des filtres d'extraction a rendement extremement eleve (type pour cellules emettrices {alpha} concu pour etre change sans risque de contamination, type pour cellules emettrices {gamma}: concu pour etre change a distance) La filtration des reacteurs nucleaires sont egalement effectuee par des papiers filtres: - reacteur G1 a circuit ouvert: air de refroidissement totalement filtre a l'aspiration et a l'extraction; - reacteurs G2, G3, EDF1: a circuit ferme: filtration sous pression d'une faible partie du gaz de refroidissement. (auteur)

  5. Fisheries Radiobiology and the Discharge of Radioactive Wastes; Radiobiologie des Pecheries et Evacuation des Dechets Radioactifs; 041f 0420 0418 014 ; Radiobiologia de las Pesquerias y Evacuacion de Desechos Radiactivos

    Energy Technology Data Exchange (ETDEWEB)

    Morgan, F. [Fisheries Radiobiological Laboratory, Ministry of Agriculture, Fisheries and Food (United Kingdom)

    1960-07-01

    In the United Kingdom authorizations to discharge radioactive wastes are granted by the Minister of Housing and Local Government, the Minister of Agriculture, Fisheries and Food, and by the Secretary of State for Scotland. The hazards arising from contamination of aquatic animals and plants concern the Department of Fisheries ; before authorizations to discharge liquid wastes have been given, the Department has made independent forecasts of permissible levels of discharge based on extensive studies carried out in its research vessels and radiobiological laboratory: for example, where fish have been affected this has meant studies of fish populations and fish migration: uptake of radioactivity by fish : public consumption of fish : commercial distribution of affected fish: L.D.{sub 50}: effects of radiation on tissue, etc. In the course of such work there has been close consultation with the Atomic Energy Authority, and agreement with the Atomic Energy Authority about the safety factor to be incorporated during the first two years of discharge. During these two years, monitoring data collected by the Atomic Energy Authority and the Ministry of Agriculture, Fisheries and Food enable checks and revisions of the original estimates to be made, and at the end of that time formal authorizations, based on operating experience, are issued. (author) [French] Au Royaume-Uni, les autorisations d'evacuer des dechets radioactifs sont accordees par le Ministre du logement et de l'administration locale, par le Ministre de l'agriculture, des pecheries et de l'alimentation et par le Secretaire d'Etat pour l'Ecosse. Les risques dus a la contamination des animaux et des plantes aquatiques relevent du Departement des pecheries; avant d'accorder des autorisations d'evacuer des dechets liquides, le Departement a evalue lui-meme les quantites dont l'evacuation pourrait etre admise, en se fondant sur des etudes approfondies qui sont faites dans ses bateaux de recherche et son laboratoire

  6. On the Waste Disposal Potentiality of the Atmosphere; Possibilites d'Elimination des Dechets Radioactifs dans l'Atmosphere; 041a 0412 041e 041f 0414 ; Sobre la Posibilidad de Evacuar Desechos en la Atmosfera

    Energy Technology Data Exchange (ETDEWEB)

    Small, S. H.; Storebo, P. B. [Norwegian Defence Research Establishment (Norway)

    1960-07-01

    The whole scale of atmospheric mixing, transport and removal processes is reviewed. Certain measurements indicate replacement of stratospheric air within about two years, making high-altitude disposal of radioactive waste materials even less attractive than earlier assumed. Deposition of radioactive materials is to some extent systematically non-uniform, and permissible levels of atmospheric radioactivity should be based upon the probable hazards in the most exposed regions, e.g. regions of considerable orographic precipitation. In connexion with the measurement of atmospheric radioactivity, it is pointed out that sampling techniques should cover the probable effects of gradual changes in particle sizes, and removal of particles by settling, impingement and absorption on vegetation and buildings etc. Meteorological problems in connexion with radiation monitoring and warning systems are discussed in relation to reactor operations. Technical details of relatively simple warning systems are given. (author) [French] Les auteurs examinent l'ensemble des processus suivant lesquels les dechets radioactifs sont brasses, transportes et disperses dans les couches atmospheriques. Certaines mesures indiquent que le renouvellement des masses d'air stratospheriques se fait' en moins de deux ans environ; la possibilite d'eliminer les dechets radioactifs dans les couches superieures de l'atmosphere semble donc encore moins seduisante qu'elle ne le paraissait tout d'abord. On peut dire que, dans une certaine mesure, le depot des substances radioactives s'effectue systematiquement de facon non uniforme; pour determiner le taux de radioactivite atmospherique admissible, il faut donc se baser sur les risques probables encourus dans les regions les plus exposees, par exemple dans les regions a fortes precipitations orographiques. En ce qui concerne la mesure de la radioactivite atmospherique, les techniques d'echantillonnage devraient tenir compte des consequences probables de la

  7. Detection of atmospheric tritium by scintillation. Variations in its concentration in France; Detection du tritium atmospherique par scintillation. Evolution de sa concentration en France

    Energy Technology Data Exchange (ETDEWEB)

    Bibron, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-06-01

    The tritium released into the atmosphere as a result of the explosion of thermonuclear devices is a useful radioactive tracer for the study of certain geophysical problems. The low concentrations found however call for the use of extremely sensitive detectors. Two detection methods using liquid scintillators are described. In the first method, the sample is introduced into the scintillator in liquid form, after prior concentration of the tritium by electrolysis. In the second method the tritium is incorporated into the scintillator solvent molecule by chemical synthesis. In the last part of the report are examined the variations in the tritium concentration in rain-water and of the free hydrogen in the air in France. A discussion is then made of the seasonal variations in the case of rain-water and these are compared to the variations in the strontium-90 concentrations. (author) [French] Le tritium introduit dans l'atmosphere par les explosions d'armes thermonucleaires est un traceur radioactif Interessant pour l'etude de certains problemes de geophysique. Les faibles concentrations rencontrees obligent toutefois a utiliser des detecteurs extremement sensibles. On decrit deux methodes de detection utilisant des scintillateurs liquides. Dans la premiere methode, l'echantillon est introduit dans le scintillateur, sous forme aqueuse, apres une concentration prealable du tritium par electrolyse. Dans la seconde methode, le tritium est incorpore a la molecule du solvant du scintillateur par synthese chimique. Dans la derniere partie du rapport, on examine l'evolution de la concentration du tritium dans les eaux de precipitation et l'hydrogene libre de l'air en France. On discute ensuite les variations saisonnieres dans le cas des eaux de precipitation et on les compare aux variations du strontium 90. (auteur)

  8. Detection of atmospheric tritium by scintillation. Variations in its concentration in France; Detection du tritium atmospherique par scintillation. Evolution de sa concentration en France

    Energy Technology Data Exchange (ETDEWEB)

    Bibron, R. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-06-01

    The tritium released into the atmosphere as a result of the explosion of thermonuclear devices is a useful radioactive tracer for the study of certain geophysical problems. The low concentrations found however call for the use of extremely sensitive detectors. Two detection methods using liquid scintillators are described. In the first method, the sample is introduced into the scintillator in liquid form, after prior concentration of the tritium by electrolysis. In the second method the tritium is incorporated into the scintillator solvent molecule by chemical synthesis. In the last part of the report are examined the variations in the tritium concentration in rain-water and of the free hydrogen in the air in France. A discussion is then made of the seasonal variations in the case of rain-water and these are compared to the variations in the strontium-90 concentrations. (author) [French] Le tritium introduit dans l'atmosphere par les explosions d'armes thermonucleaires est un traceur radioactif Interessant pour l'etude de certains problemes de geophysique. Les faibles concentrations rencontrees obligent toutefois a utiliser des detecteurs extremement sensibles. On decrit deux methodes de detection utilisant des scintillateurs liquides. Dans la premiere methode, l'echantillon est introduit dans le scintillateur, sous forme aqueuse, apres une concentration prealable du tritium par electrolyse. Dans la seconde methode, le tritium est incorpore a la molecule du solvant du scintillateur par synthese chimique. Dans la derniere partie du rapport, on examine l'evolution de la concentration du tritium dans les eaux de precipitation et l'hydrogene libre de l'air en France. On discute ensuite les variations saisonnieres dans le cas des eaux de precipitation et on les compare aux variations du strontium 90. (auteur)

  9. Christian Marclay : « iconoclasme » musical et interrogation sur l’instrument

    Directory of Open Access Journals (Sweden)

    Marianne Massin

    2011-03-01

    Full Text Available Le travail de Christian Marclay, artiste multiforme, improvisateur et performer, explore systématiquement un espace au confluent des arts sonores et visuels (vidéo, photos, installations, sculptures. Comment réfléchir sur le son à travers les objets tangibles et les représentations visuelles qui le réifient ? Comment produire – par une pratique musicale de platiniste notamment – de nouveaux sons et de nouveaux rapports à la musique ? Ce double axe d’interrogation rencontre nécessairement la question de l’instrument. Iconoclasme musical dans la double lignée du mouvement punk et de Fluxus ? Ou /et interrogation sur le fonctionnement de l’instrument dans la pratique vive d’une musique à réinventer ? On voudrait suggérer qu’une telle approche esthétique peut nourrir l’approche ontologique de l’instrument et, en paraphrasant Nelson Goodman, poser la question « quand y a-t-il instrument ? ».Christian Marclay : Musical « iconoclasism » and an instrumental interrogative Christian Marclay a polyvalent/multiform artist who improvises and performs. His work systematically explores the artistic space where audio arts and visual arts (video, photos, installations and sculpture merge. How can sound be considered in relation to tangible objects and visual representations that give it some actuality ? How can new sounds and new relationships with music be produced by any musical output for example of a turntablist ? This bilateral enquiry necessarily confronts the topic of the instrument. Is it a musical iconoclasism in the dynamic of both punk and Fluxus ? Or/and a questioning of the way the instrument works while a vivid musical practice has to be reinvented? It is suggested that such an esthetical approach may feed the ontological approach of the instrument and, to paraphrase Nelson Goodman, ask the question “When is something an instrument ?”.

  10. Conditioning of solid radioactive wastes (1960); Conditionnement des dechets radioactifs solides (1960)

    Energy Technology Data Exchange (ETDEWEB)

    Cerre, P [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    Since solid radioactive wastes are of varied forms, dimensions and volumes, the C.E.A. first reduces the volume by breaking up and compacting. Since these wastes cannot be temporarily stored without contamination risk, an effective packing process has been devised and carried through. This consists in burying the wastes in a specially planned concrete with the following characteristics: - high mechanical resistance; - maximum insolubility; - resistance to corrosion; - maximum imperviousness; - providing protection against radiation. It is then possible to store the blocks safely, with a view to eventual definitive rejection. (author) [French] Les dechets actifs solides etant de formes, de dimensions et de volumes varies, le C.E.A. procede en premier lieu a une reduction de volume par fractionnement et compactage. L'emmagasinage provisoire de tels dechets ne pouvant se concevoir sans risques de contamination, un procede efficace d'emballage a ete etudie et realise. Il consiste a noyer les dechets dans un beton specialement etudie qui presente les caracteristiques suivantes: - forte resistance mecanique; - insolubilite maximum; - resistance a la corrosion; - etancheite maximum; - protection contre le rayonnement. Il est alors possible de conserver sans danger les blocs formes en vue d'un rejet definitif ulterieur. (auteur)

  11. Directed and persistent movement arises from mechanochemistry of the ParA/ParB system.

    Science.gov (United States)

    Hu, Longhua; Vecchiarelli, Anthony G; Mizuuchi, Kiyoshi; Neuman, Keir C; Liu, Jian

    2015-12-22

    The segregation of DNA before cell division is essential for faithful genetic inheritance. In many bacteria, segregation of low-copy number plasmids involves an active partition system composed of a nonspecific DNA-binding ATPase, ParA, and its stimulator protein ParB. The ParA/ParB system drives directed and persistent movement of DNA cargo both in vivo and in vitro. Filament-based models akin to actin/microtubule-driven motility were proposed for plasmid segregation mediated by ParA. Recent experiments challenge this view and suggest that ParA/ParB system motility is driven by a diffusion ratchet mechanism in which ParB-coated plasmid both creates and follows a ParA gradient on the nucleoid surface. However, the detailed mechanism of ParA/ParB-mediated directed and persistent movement remains unknown. Here, we develop a theoretical model describing ParA/ParB-mediated motility. We show that the ParA/ParB system can work as a Brownian ratchet, which effectively couples the ATPase-dependent cycling of ParA-nucleoid affinity to the motion of the ParB-bound cargo. Paradoxically, this resulting processive motion relies on quenching diffusive plasmid motion through a large number of transient ParA/ParB-mediated tethers to the nucleoid surface. Our work thus sheds light on an emergent phenomenon in which nonmotor proteins work collectively via mechanochemical coupling to propel cargos-an ingenious solution shaped by evolution to cope with the lack of processive motor proteins in bacteria.

  12. Scoping studies - photon and low energy neutron interrogation

    Energy Technology Data Exchange (ETDEWEB)

    Becker, G.; Harker, Y.; Jones, J. [LMITCo, Idaho Falls, ID (United States); Harmon, F. [Idaho State Univ., Pocatello, ID (United States)

    1997-11-01

    High energy photon interrogation of waste containers, with the aim of producing photo nuclear reactions, in specific materials, holds the potential of good penetration and rapid analysis. Compact high energy ({le} 10 MeV) photon sources in the form of electron linacs producing bremstrahlung radiation are readily available. Work with the Varitron variable energy accelerator at ISU will be described. Advantages and limitations of the technique will be discussed. Using positive ion induced neutron producing reactions, it is possible to generate neutrons in a specific energy range. By this means, variable penetration and specific reactions can be excited in the assayed material. Examples using the {sup 3}H(p,n) and {sup 7}Li(p,n) reactions as neutron sources will be discussed. 4 refs., 7 figs.

  13. Psychologists abandon the Nuremberg ethic: concerns for detainee interrogations.

    Science.gov (United States)

    Pope, Kenneth S; Gutheil, Thomas G

    2009-01-01

    In the aftermath of 9-11, the American Psychological Association, one of the largest U.S. health professions, changed its ethics code so that it now runs counter to the Nuremberg Ethic. This historic post-9-11 change allows psychologists to set aside their ethical responsibilities whenever they are in irreconcilable conflict with military orders, governmental regulations, national and local laws, and other forms of governing legal authority. This article discusses the history, wording, rationale, and implications of the ethical standard that U.S. psychologists adopted 7 years ago, particularly in light of concerns over health care professionals' involvement in detainee interrogations and the controversy over psychologists' prominent involvement in settings like the Guantánamo Bay Detainment Camp and the Abu Ghraib prison. It discusses possible approaches to the complex dilemmas arising when ethical responsibilities conflict with laws, regulations, or other governing legal authority.

  14. Genome interrogation for novel salinity tolerant Arabidopsis mutants.

    Science.gov (United States)

    van Tol, Niels; Pinas, Johan; Schat, Henk; Hooykaas, Paul J J; van der Zaal, Bert J

    2016-12-01

    Soil salinity is becoming an increasingly large problem in agriculture. In this study, we have investigated whether a capacity to withstand salinity can be induced in the salinity sensitive plant species Arabidopsis thaliana, and whether it can be maintained in subsequent generations. To this end, we have used zinc finger artificial transcription factor (ZF-ATFs) mediated genome interrogation. Already within a relatively small collection Arabidopsis lines expressing ZF-ATFs, we found 41 lines that were tolerant to 100 mM NaCl. Furthermore, ZF-ATF encoding gene constructs rescued from the most strongly salinity tolerant lines were indeed found to act as dominant and heritable agents for salinity tolerance. Altogether, our data provide evidence that a silent capacity to withstand normally lethal levels of salinity exists in Arabidopsis and can be evoked relatively easily by in trans acting transcription factors like ZF-ATFs. © 2016 John Wiley & Sons Ltd.

  15. Time-dependent delayed signatures from energetic photon interrogations

    International Nuclear Information System (INIS)

    Norman, Daren R.; Jones, James L.; Blackburn, Brandon W.; Haskell, Kevin J.; Johnson, James T.; Watson, Scott M.; Hunt, Alan W.; Spaulding, Randy; Harmon, Frank

    2007-01-01

    Pulsed photonuclear interrogation environments generated by 8-24 MeV electron linac are rich with time-dependent, material-specific, radiation signatures. Nitrogen-based explosives and nuclear materials can be detected by exploiting these signatures in different delayed-time regions. Numerical and experimental results presented in this paper show the unique time and energy dependence of these signatures. It is shown that appropriate delayed-time windows are essential to acquire material-specific signatures in pulsed photonuclear assessment environments. These developments demonstrate that pulsed, high-energy, photon-inspection environments can be exploited for time-dependent, material-specific signatures through the proper operation of specialized detectors and detection methods

  16. Queering marriage: an ideographic interrogation of heteronormative subjectivity.

    Science.gov (United States)

    Grindstaff, Davin

    2003-01-01

    Recent debates on same-sex marriage mark the institution, practice, and concept of marriage as a significant site of power and resistance within American culture. Adopting Michel Foucault's conception of "discipline," this essay examines how marriage discourse reinforces heteronormative power relations through its rhetorical constitution of gay male identity. Supplementing "ideographic" critique with Judith Butler's theory of performative speech acts enables us to better interrogate and resist these operations of power. This essay maps the contemporary scene of heteronormative power and resistance through two rhetorical performances of gay male identity. The marriage debates, in the first instance, demonstrate how a conventional desire for masculine agency influences the heteronormative production of gay male identity. In the second instance, gay male SM [sadomasochism] performs a concept of "relational agency," which potentially resists heteronormativity.

  17. Design and characterisation of a pulsed neutron interrogation facility

    International Nuclear Information System (INIS)

    Favalli, A.; Pedersen, B.

    2007-01-01

    The Joint Research Centre recently obtained a license to operate a new experimental device intended for research in the field of nuclear safeguards. The research projects currently being planned for the new device includes mass determination of fissile materials in matrices and detection of contraband non-nuclear materials. The device incorporates a commercial pulsed neutron generator and a large graphite mantle surrounding the sample cavity. In this configuration, a relatively high thermal neutron flux with a long lifetime is achieved inside the sample cavity. By pulsing the neutron generator, a sample may be interrogated by a pure thermal neutron flux during repeated time periods. The paper reports on the design of the new device and the pulsed fast and thermal neutron source. The thermal neutron flux caused by the neutron generator and the graphite structure has been characterised by foil activation, fission chamber and 3 He proportional counter measurements. (authors)

  18. The Sociocultural Psychology as a Postformal Theory of Academic Achievement: Interrogating Formal Education

    Science.gov (United States)

    Sinha, Chetan

    2013-01-01

    The present paper interrogates the dominance of formal education. As formal education system relies on ability based academic achievement as a goal, exploring post-formal approaches, such as sociocultural notion of academic achievement is the hallmark of present paper. An attempt is made to interrogate the existing cultural dominance in formal…

  19. Active Interrogation of Sensitive Nuclear Material Using Laser Driven Neutron Beams

    International Nuclear Information System (INIS)

    Favalli, Andrea; Roth, Markus

    2015-01-01

    An investigation of the viability of a laser-driven neutron source for active interrogation is reported. The need is for a fast, movable, operationally safe neutron source which is energy tunable and has high-intensity, directional neutron production. Reasons for the choice of neutrons and lasers are set forth. Results from the interrogation of an enriched U sample are shown.

  20. Using Elaborative Interrogation Enhanced Worked Examples to Improve Chemistry Problem Solving

    Science.gov (United States)

    Pease, Rebecca Simpson

    2012-01-01

    Elaborative interrogation, which prompts students to answer why-questions placed strategically within informational text, has been shown to increase learning comprehension through reading. In this study, elaborative interrogation why-questions requested readers to explain why paraphrased statements taken from a reading were "true."…

  1. Diagnostic yield of device interrogation in the evaluation of syncope in an elderly population.

    Science.gov (United States)

    D'Angelo, Robert N; Pickett, Christopher C

    2017-06-01

    Device interrogation has become a standard part of the syncope evaluation for patients admitted with permanent pacemakers (PPM) or implantable cardiac defibrillators (ICD), although few studies have shown interrogation yields clinically useful data. The purpose of this study is to determine the diagnostic yield of device interrogation as well as other commonly performed tests in the workup of unexplained syncope in patients with previously implanted PPMs or ICDs. We retrospectively reviewed records of 88 patients admitted to our medical center for syncope with previously implanted pacemakers between January 1, 2005 and January 1, 2015 using ICD-9 billing data. Pacemaker interrogation demonstrated an arrhythmia as the cause for syncope in 4 patients (4%) and evidence of device failure secondary to perforation in 1 patient (1%). The cause of syncope was unknown in 34 patients (39%). Orthostatic hypotension was the most commonly identified cause of syncope (26%), followed by vasovagal syncope (13%), autonomic dysfunction (5%), ventricular arrhythmia (3%), atrial arrhythmia (2%), congestive heart failure (2%), stroke (2%), and other less common causes (8%). History was the most important determinant of syncope (36%), followed by orthostatic vital signs (14%), device interrogations (4%), head CT (2%), and transthoracic echocardiogram (1%). Device interrogation is rarely useful for elucidating a cause of syncope without concerning physical exam, telemetry, or EKG findings. Interrogation may occasionally yield paroxysmal arrhythmias responsible for syncopal episode, but these rarely alter clinical outcomes. Interrogation appears to be more useful in patients with syncope after recent device placement. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  2. Interrogating "Belonging" in Belonging, Being and Becoming: The Early Years Learning Framework for Australia

    Science.gov (United States)

    Sumsion, Jennifer; Wong, Sandie

    2011-01-01

    In this article, the authors interrogate the use of "belonging" in "Belonging, Being and Becoming: the Early Years Learning Framework for Australia" (EYLF), Australia's first national curriculum for early childhood education and care settings and, from the authors' interrogation, possibilities are offered for thinking about and…

  3. Study of the diffusion of iron, of silver and of carbon in beryllium using radioactive tracers; Etude de la diffusion du fer, de l'argent et du carbone dans le beryllium au moyen des traceurs radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    Naik, M Ch [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-06-01

    A study has been made of the diffusion of radioactive iron and silver tracers in beryllium. The following values have been found. D{sub Fe} = 0.53 exp - [51800 / RT], D{sub Ag} = 62 exp - [46100 / RT]. The values for iron are in good agreement with those found previously for chemical diffusion. A comparison of the diffusion coefficients for iron, silver and nickel shows that the diffusion rate increases with increasing solute atom radius. The existence has been shown of diffusion anisotropy for silver; it has been studied quantitatively on monocrystals. It is found that: D{sub parallel} 0.41 exp - [39100 / RT], D{sub perpendicular} = 1.98 exp - [45700 / RT]. The anisotropy decreases as the temperature increases. The silver diffuses more rapidly along the C axis than in the base plane. This result cannot be explained in terms of the model proposed for the diffusion of foreign atoms in solution in zinc. A greater number of experiments is required before a model can be put forward. An attempt has also been made to determine the diffusion coefficients of carbon in beryllium by treatment in an atmosphere of acetylene marked with C-14. Diffusion coefficients have been obtained but these should not be considered to be very significant since a chemical reaction occurs at the surface of the samples. (author) [French] On a etudie la diffusion dans le beryllium de traceurs radioactifs du fer et de l'argent. On trouve: D{sub Fe} = 0.53 exp - [51800 / RT], D{sub Ag} = 62 exp - [46100 / RT].Les valeurs trouvees pour le fer sont en bon accord avec les valeurs obtenues precedemment pour la diffusion chimique. La comparaison des coefficients de diffusion du fer, de l'argent et du nickel montre que la diffusion est d'autant plus rapide que le rayon atomique du solute est plus grand. On a mis en evidence une anisotropie de diffusion de l'argent qui a ete etudiee quantitativement sur des monocristaux. On trouve: D{sub parallele} = 0.41 exp - [39100 / RT], D{sub perpendiculaire} = 1

  4. Interrogated with Intellectual Disabilities: The Risks of False Confession.

    Science.gov (United States)

    Schatz, Samson J

    2018-02-01

    False confessions happen. At least 245 people have been exonerated from convictions in cases featuring confessions that were simply not true. Confessions offer a narrative that allows law enforcement, and society in general, to neatly resolve cases with apparent clarity and closure. And yet the pressures officers place on suspects to provide that closure weigh disproportionately on the vulnerable, including individuals with intellectual disabilities. These individuals are disadvantaged at every step of the custodial interrogation, and they face heightened risks of falsely confessing. Moreover, the principal judicial safeguards against false confessions--assessing a suspect's Miranda waiver and determining whether a confession was voluntarily given within the bounds of the Fourteenth Amendment’s Due Process Clause--provide little protection for the innocent with intellectual disabilities. Few pieces of scholarship focus specifically on the heightened risks faced by individuals with intellectual disabilities throughout the process of police interrogation. This Note describes the various ways these individuals are disadvantaged. And it offers an additional data point illustrating the vulnerability of people with intellectual disabilities. This Note analyzes the 245 individuals (as of June 2, 2017) on the National Registry of Exonerations who have falsely confessed. Over one-quarter of them display indicia of intellectual disability. This percentage dwarfs the prevalence of people with intellectual disabilities in the general population and even exceeds most estimates of the proportion of the prison population suffering from intellectual disabilities. This Note concludes with several policy and doctrinal suggestions to better protect individuals with intellectual disabilities from the risks of false confession.

  5. Coaxial Mono-Energetic Gamma Generator for Active Interrogation

    International Nuclear Information System (INIS)

    Ludewigt, Bernhard A.; Antolak, A.J.; Henestroza, E.; Leitner, M.; Leung, K.-N.; Waldron, W.; Wilde, S.; Kwan, J.W.

    2008-01-01

    Compact mono-energetic photon sources are sought for active interrogation systems to detect shielded special nuclear materials in, for example, cargo containers, trucks and other vehicles. A prototype gamma interrogation source has been designed and built that utilizes the 11B(p,gamma)12C reaction to produce 12 MeV gamma-rays which are near the peak of the photofission cross section. In particular, the 11B(p,gamma)12C resonance at 163 kV allows the production of gammas at low proton acceleration voltages, thus keeping the design of a gamma generator comparatively small and simple. A coaxial design has been adopted with a toroidal-shaped plasma chamber surrounding a cylindrical gamma production target. The plasma discharge is driven by a 2 MHz rf-power supply (capable up to 50 kW) using a circular rf-antenna. Permanent magnets embedded in the walls of the plasma chamber generate a multi-cusp field that confines the plasma and allows higher plasma densities and lower gas pressures. About 100 proton beamlets are extracted through a slotted plasma electrode towards the target at the center of the device that is at a negative 180 kV. The target consists of LaB6 tiles that are brazed to a water-cooled cylindrical structure. The generator is designed to operate at 500 Hz with 20 mu s long pulses, and a 1percent duty factor by pulsing the ion source rf-power. A first-generation coaxial gamma source has been built for low duty factor experiments and testing.

  6. Improved Fission Neutron Data Base for Active Interrogation of Actinides

    Energy Technology Data Exchange (ETDEWEB)

    Pozzi, Sara; Czirr, J. Bart; Haight, Robert; Kovash, Michael; Tsvetkov, Pavel

    2013-11-06

    This project will develop an innovative neutron detection system for active interrogation measurements. Many active interrogation methods to detect fissionable material are based on the detection of neutrons from fission induced by fast neutrons or high-energy gamma rays. The energy spectrum of the fission neutrons provides data to identify the fissionable isotopes and materials such as shielding between the fissionable material and the detector. The proposed path for the project is as follows. First, the team will develop new neutron detection systems and algorithms by Monte Carlo simulations and bench-top experiments. Next, They will characterize and calibrate detection systems both with monoenergetic and white neutron sources. Finally, high-fidelity measurements of neutron emission from fissions induced by fast neutrons will be performed. Several existing fission chambers containing U-235, Pu-239, U-238, or Th-232 will be used to measure the neutron-induced fission neutron emission spectra. The challenge for making confident measurements is the detection of neutrons in the energy ranges of 0.01 – 1 MeV and above 8 MeV, regions where the basic data on the neutron energy spectrum emitted from fission is least well known. In addition, improvements in the specificity of neutron detectors are required throughout the complete energy range: they must be able to clearly distinguish neutrons from other radiations, in particular gamma rays and cosmic rays. The team believes that all of these challenges can be addressed successfully with emerging technologies under development by this collaboration. In particular, the collaboration will address the area of fission neutron emission spectra for isotopes of interest in the advanced fuel cycle initiative (AFCI).

  7. Thermal neutron imaging in an active interrogation environment

    International Nuclear Information System (INIS)

    Vanier, P.E.; Forman, L.; Norman, D.R.

    2009-01-01

    We have developed a thermal-neutron coded-aperture imager that reveals the locations of hydrogenous materials from which thermal neutrons are being emitted. This imaging detector can be combined with an accelerator to form an active interrogation system in which fast neutrons are produced in a heavy metal target by means of excitation by high energy photons. The photo-induced neutrons can be either prompt or delayed, depending on whether neutronemitting fission products are generated. Provided that there are hydrogenous materials close to the target, some of the photo-induced neutrons slow down and emerge from the surface at thermal energies. These neutrons can be used to create images that show the location and shape of the thermalizing materials. Analysis of the temporal response of the neutron flux provides information about delayed neutrons from induced fission if there are fissionable materials in the target. The combination of imaging and time-of-flight discrimination helps to improve the signal-to-background ratio. It is also possible to interrogate the target with neutrons, for example using a D-T generator. In this case, an image can be obtained from hydrogenous material in a target without the presence of heavy metal. In addition, if fissionable material is present in the target, probing with fast neutrons can stimulate delayed neutrons from fission, and the imager can detect and locate the object of interest, using appropriate time gating. Operation of this sensitive detection equipment in the vicinity of an accelerator presents a number of challenges, because the accelerator emits electromagnetic interference as well as stray ionizing radiation, which can mask the signals of interest.

  8. Miniature fiber Bragg grating sensor interrogator (FBG-Transceiver) system

    Science.gov (United States)

    Mendoza, Edgar A.; Kempen, Cornelia; Lopatin, Craig

    2007-04-01

    This paper describes recent progress conducted towards the development of a miniature fiber Bragg grating sensor interrogator (FBG-Transceiver TM) system based on multi-channel integrated optic sensor (InOSense TM) microchip technology. The hybrid InOSense TM microchip technology enables the integration of all of the functionalities, both passive and active, of conventional bench top FBG sensor interrogator systems, packaged in a miniaturized, low power operation, 2-cm x 5-cm package suitable for the long-term structural health monitoring in applications where size, weight, and power are critical for operation. The FBG-Transceiver system uses active optoelectronic components monolithically integrated to the InOSense TM microchip, a microprocessor controlled signal processing electronics board capable of processing the FBG sensors signals related to stress-strain and temperature as well as vibration and acoustics. The FBG-Transceiver TM system represents a new, reliable, highly robust technology that can be used to accurately monitor the status of an array of distributed fiber optic Bragg grating sensors installed in critical infrastructures. Its miniature package, low power operation, and state-of-the-art data communications architecture, all at a very affordable price makes it a very attractive solution for a large number of SHM/NDI applications in aerospace, naval and maritime industry, civil structures like bridges, buildings and dams, the oil and chemical industry, and for homeland security applications. The miniature, cost-efficient FBG-Transceiver TM system is poised to revolutionize the field of structural health monitoring and nondestructive inspection market. The sponsor of this program is NAVAIR under a DOD SBIR contract.

  9. Are the American Psychological Association's Detainee Interrogation Policies Ethical and Effective?: Key Claims, Documents, and Results.

    Science.gov (United States)

    Pope, Kenneth S

    2011-01-01

    After 9-11, the United States began interrogating detainees at settings such as Abu Ghraib, Bagram, and Guantanamo. The American Psychological Association (APA) supported psychologists' involvement in interrogations, adopted formal policies, and made an array of public assurances. This article's purpose is to highlight key APA decisions, policies, procedures, documents, and public statements in urgent need of rethinking and to suggest questions that may be useful in a serious assessment, such as, "However well intended, were APA's interrogation policies ethically sound?"; "Were they valid, realistic, and able to achieve their purpose?"; "Were other approaches available that would address interrogation issues more directly, comprehensively, and actively, that were more ethically and scientifically based, and that would have had a greater likelihood of success?"; and "Should APA continue to endorse its post-9-11 detainee interrogation policies?"

  10. Are the American Psychological Association’s Detainee Interrogation Policies Ethical and Effective?

    Science.gov (United States)

    Pope, Kenneth S.

    2011-01-01

    After 9–11, the United States began interrogating detainees at settings such as Abu Ghraib, Bagram, and Guantanamo. The American Psychological Association (APA) supported psychologists’ involvement in interrogations, adopted formal policies, and made an array of public assurances. This article’s purpose is to highlight key APA decisions, policies, procedures, documents, and public statements in urgent need of rethinking and to suggest questions that may be useful in a serious assessment, such as, “However well intended, were APA’s interrogation policies ethically sound?”; “Were they valid, realistic, and able to achieve their purpose?”; “Were other approaches available that would address interrogation issues more directly, comprehensively, and actively, that were more ethically and scientifically based, and that would have had a greater likelihood of success?”; and “Should APA continue to endorse its post-9–11 detainee interrogation policies?” PMID:22096660

  11. On velocity space interrogation regions of fast-ion collective Thomson scattering at ITER

    DEFF Research Database (Denmark)

    Salewski, Mirko; Nielsen, Stefan Kragh; Bindslev, Henrik

    2011-01-01

    the collective scattering in well-defined regions in velocity space, here dubbed interrogation regions. Since the CTS instrument measures entire spectra of scattered radiation, many different interrogation regions are probed simultaneously. We here give analytic expressions for weight functions describing...... the interrogation regions, and we show typical interrogation regions of the proposed ITER CTS system. The backscattering system with receivers on the low-field side is sensitive to fast ions with pitch |p| = |v/v| ... scattering system with receivers on the high-field side would be sensitive to co- and counter-passing fast ions in narrow interrogation regions with pitch |p| > 0.6–0.8. Additionally, we use weight functions to reconstruct 2D fast-ion distribution functions, given two projected 1D velocity distribution...

  12. Lies and coercion: why psychiatrists should not participate in police and intelligence interrogations.

    Science.gov (United States)

    Janofsky, Jeffrey S

    2006-01-01

    Police interrogators routinely use deceptive techniques to obtain confessions from criminal suspects. The United States Executive Branch has attempted to justify coercive interrogation techniques in which physical or mental pain and suffering may be used during intelligence interrogations of persons labeled unlawful combatants. It may be appropriate for law enforcement, military, or intelligence personnel who are not physicians to use such techniques. However, forensic psychiatry ethical practice requires honesty, striving for objectivity, and respect for persons. Deceptive and coercive interrogation techniques violate these moral values. When a psychiatrist directly uses, works with others who use, or trains others to use deceptive or coercive techniques to obtain information in police, military, or intelligence interrogations, the psychiatrist breaches basic principles of ethics.

  13. A pilot study of implantable cardiac device interrogation by emergency department personnel.

    Science.gov (United States)

    Neuenschwander, James F; Hiestand, Brian C; Peacock, W Frank; Billings, John M; Sondrup, Cole; Hummel, John D; Abraham, William T

    2014-03-01

    Implanted devices (eg, pacemakers and defibrillators) provide valuable information and may be interrogated to obtain diagnostic information and to direct management. During admission to an emergency department (ED), significant time and cost are spent waiting for device manufacturer representatives or cardiologists to access the data. If ED personnel could safely interrogate implanted devices, more rapid disposition could occur, thus leading to potentially better outcomes at a reduced cost. This was a pilot study examining the feasibility of ED device interrogation. This was a prospective convenience sample study of patients presenting to the ED with any chief complaint and who had an implantable device capable of being interrogated by a Medtronic reader. After obtaining informed consent, study patients underwent device interrogation by ED research personnel. After reviewing the device data, the physician documented their opinions of the value of data in aiding care. Patients were followed up at intervals ranging from 30 days out to 1 year to determine adverse events relating to interrogation. Forty-four patients underwent device interrogation. Their mean age was 56 ± 14.7 years (range, 28-83), 75% (33/44) were male and 75% (33/44) were hospitalized from the ED. The interrogations took less than 10 minutes 89% of the time. In 60% of the cases, ED physicians reported the data-assisted patient care. No adverse events were reported relating to the ED interrogations. In this pilot study, we found that ED personnel can safely and quickly interrogate implantable devices to obtain potentially useful clinical data.

  14. Recherche documentaire par titrage automatique

    OpenAIRE

    Lopez , Cédric; Prince , Violaine; Roche , Mathieu

    2011-01-01

    Nous proposons dans cet article un système facilitant la recherche d'information dans un ensemble de documents textuels, basé sur le titrage (et sous-titrage) automatique. Ce dernier peut se révéler crucial, par exemple, dans le cadre de la problématique de l'accessibilité des pages web (norme W3C). Notre processus de titrage automatique consiste à extraire des syntagmes nominaux pertinents dans les textes, pouvant constituer des titres ou sous-titres candidats. Une approche originale combina...

  15. Le télé-achat : finalité ou usage par défaut des nouvelles convergences ?

    OpenAIRE

    Lenoir , Christophe

    2000-01-01

    HAL : hal-00558853; International audience; Le télé-achat relève-t-il d'une finalité ou d'un usage par défaut des nouvelles convergences ? A partir des questions de détermination technologique et d'indétermination des usages, cet article propose, au vu de l'évolution économique du secteur et de l'information économique véhiculée par ses agents, de s'interroger sur les conditions énonciatives de ces processus de communication et leurs conséquences sur le médium télévisuel.

  16. SECHAGE DE PRODUITS GRANULAIRES PAR DESHYDRATATION PAR DETENTES SUCCESSIVES (DDS)

    OpenAIRE

    Abdulla , Galal; Mellouk , Hamid; Belghit , Abdelhamid; Allaf , Karim

    2009-01-01

    International audience; Dans cette étude, nous avons évalué les performances d'un nouveau procédé de séchage dans le cas du liège en granulés. Ce procédé (La déshydratation par détentes successives : DDS) consiste à soumettre le matériau liège dans une chambre hermétique aux variations cycliques de la pression. Chaque cycle est composé d'une compression et d'une décompression. La phase de compression est réalisée en injectant de l'air comprimé à température ambiante provenant d'un compresseur...

  17. A SYSTEMATIC APPROACH TO THE PSYCHOLOGICAL IMPACT OF THE INVESTIGATOR ON A PERSON BEING INTERROGATED

    Directory of Open Access Journals (Sweden)

    Ivan Cherevko

    2017-03-01

    Full Text Available The subject of the research is an interaction with a person being interrogated organized by an investigator with the use of his interests, needs and other individual-mental features, his reinforcement, which must be done through secretive, invisible influence in an organized situation encouraging to do deeds desirable for investigation. The object of the research is interrogation as the most psychologized investigative action. The methodological basis of the research is made by the systematic and logical approach aimed at neutralization of watchfulness of the interrogated, penetration into his inner world influencing both rational and irrational spheres of mental make-up, actualization of the unity of understanding and experience. In this research general scientific and specific scientific methods of cognition are used. General scientific methods of the research are represented by systemic structural, comparative, formal and legal, statistical methods. The approach to the psychological impact on a person being interrogated as a systemic phenomenon has enabled to develop a conceptual model presented in the form of a diagram made up of four blocks reflecting emotional background sources of interrogation procedures, the interrogated case, interaction and basic methods of psychological influence, the leading of which is persuasion. Suggestion is purposeful influence on feelings and volitional pressure acts as pressure maintenance, complementary, used depending on the situational behaviour of the interrogated. Methods of implementation of each of these methods of psychological influence are also considered in this article.

  18. What do potential jurors know about police interrogation techniques and false confessions?

    Science.gov (United States)

    Leo, Richard A; Liu, Brittany

    2009-01-01

    Psychological police interrogation methods in America inevitably involve some level of pressure and persuasion to achieve their goal of eliciting confessions of guilt from custodial suspects. In this article, we surveyed potential jurors about their perceptions of a range of psychological interrogation techniques, the likelihood that such techniques would elicit a true confession from guilty suspects, and the likelihood that such techniques could elicit a false confession from innocent suspects. Participants recognized that these interrogation techniques may be psychologically coercive and may elicit true confessions, but believed that psychologically coercive interrogation techniques are not likely to elicit false confessions. The findings from this survey study indicate that potential jurors believe that false confessions are both counter- intuitive and unlikely, even in response to psychologically coercive interrogation techniques that have been shown to lead to false confessions from the innocent. This study provides empirical support for the idea that expert witnesses may helpfully inform jurors about the social science research on psychologically coercive interrogation methods and how and why such interrogation techniques can lead to false confessions. (c) 2009 John Wiley & Sons, Ltd.

  19. Rattling nucleons: New developments in active interrogation of special nuclear material

    International Nuclear Information System (INIS)

    Runkle, Robert C.; Chichester, David L.; Thompson, Scott J.

    2012-01-01

    Active interrogation is a vigorous area of research and development due to its promise of offering detection and characterization capabilities of special nuclear material in environments where passive detection fails. The primary value added by active methods is the capability to penetrate shielding - special nuclear material itself, incidental materials, or intentional shielding - and advocates hope that active interrogation will provide a solution to the problem of detecting shielded uranium, which is at present the greatest obstacle to interdiction efforts. The technique also provides a unique benefit for quantifying nuclear material in high background-radiation environments, an area important for nuclear material safeguards and material accountancy. Progress has been made in the field of active interrogation on several fronts, most notably in the arenas of source development, systems integration, and the integration and exploitation of multiple fission and non-fission signatures. But penetration of interrogating radiation often comes at a cost, not only in terms of finance and dose but also in terms of induced backgrounds, system complexity, and extended measurement times (including set up and acquisition). These costs make the calculus for deciding to implement active interrogation more subtle than may be apparent. The purpose of this review is thus to examine existing interrogation methods, compare and contrast their attributes and limitations, and identify missions where active interrogation may hold the most promise.

  20. Territory of Upper Volta. Interest and Programme of Prospecting for Radioactive Metals; Territoire de la Haute-Volta. Interet et Programme d'une Prospection pour Metaux Radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1958-04-15

    The costs of a programme for prospecting for radioactive metals (esp. Uranium) can amount to a total cost of the order of 600 to 700 millions FF over 10 years. Such a programme represents a rather high risk, because in order to succeed, a reserve capable to pay for the programme must be found in the foreseen period. The first part of the report describes the Uranium reserves already known in Africa. [French] Un programme de prospection pour metaux radioactifs (notamment l'Uranium) pourrait etaler des depenses totales de l'ordre de 600 a 700 millions FF sur 10 ans. Un tel programme represente un risque assez grand, puisque pour reussir, il faut trouver dans le delai envisage, et avec les moyens prevus, un gisement capable d'amortir une telle depense. Une premiere partie du rapport expose les caracteres des gisments d'Uranium actuellement connus en Afrique.

  1. Nondestructive assay of subassemblies of various spent or fresh fuels by active neutron interrogation

    International Nuclear Information System (INIS)

    Ragan, G.L.; Ricker, C.W.; Chiles, M.M.; Ingersoll, D.T.; Slaughter, G.G.

    1979-01-01

    Recent studies show that subassemblies containing various spent fuels could be assayed rapidly and accurately by a nondestructive assay system using active neutron interrogation and prompt-neutron detection. Subassembly penetration is achieved by 24-keV (Sb--Be) interrogation neutrons; the spent-fuel neutron background is overridden by using strong interrogating sources and prompt-neutron signals, and background gammas are absorbed by lead. Experiments have demonstrated the potential for assaying with better than 5% accuracy, three spent plutonium-fueled subassemblies per hour. Calculations, validated by experiments, predict even better performance for fresh or uranium-fueled subassemblies; several performance estimates are given

  2. Design of Interrogation Protocols for Radiation Dose Measurements Using Optically-Stimulated Luminescent Dosimeters.

    Science.gov (United States)

    Abraham, Sara A; Kearfott, Kimberlee J; Jawad, Ali H; Boria, Andrew J; Buth, Tobias J; Dawson, Alexander S; Eng, Sheldon C; Frank, Samuel J; Green, Crystal A; Jacobs, Mitchell L; Liu, Kevin; Miklos, Joseph A; Nguyen, Hien; Rafique, Muhammad; Rucinski, Blake D; Smith, Travis; Tan, Yanliang

    2017-03-01

    Optically-stimulated luminescent dosimeters are capable of being interrogated multiple times post-irradiation. Each interrogation removes a fraction of the signal stored within the optically-stimulated luminescent dosimeter. This signal loss must be corrected to avoid systematic errors in estimating the average signal of a series of optically-stimulated luminescent dosimeter interrogations and requires a minimum number of consecutive readings to determine an average signal that is within a desired accuracy of the true signal with a desired statistical confidence. This paper establishes a technical basis for determining the required number of readings for a particular application of these dosimeters when using certain OSL dosimetry systems.

  3. Simulation of path delay multiplexing-based Fourier transform spectrometer for fiber Bragg grating interrogation.

    Science.gov (United States)

    Chelliah, Pandian; Sahoo, Trilochan; Singh, Sheela; Sujatha, Annie

    2015-10-20

    A Fourier transform spectrometer (FTS) used for interrogating a fiber Bragg grating (FBG) consists of a scanning-type interferometer. The FTS has a broad wavelength range of operation and good multiplexing capability. However, it has poor wavelength resolution and interrogation speed. We propose a modification to the FTS using path delay multiplexing to improve the same. Using this method, spatial resolution and interrogation time can be improved by n times by using n path delays. In this paper, simulation results for n=2, 5 are shown.

  4. Signal predictions for a proposed fast neutron interrogation method

    International Nuclear Information System (INIS)

    Sale, K.E.

    1992-12-01

    We have applied the Monte Carlo radiation transport code COG) to assess the utility of a proposed explosives detection scheme based on neutron emission. In this scheme a pulsed neutron beam is generated by an approximately seven MeV deuteron beam incident on a thick Be target. A scintillation detector operating in the current mode measures the neutrons transmitted through the object as a function of time. The flight time of unscattered neutrons from the source to the detector is simply related to the neutron energy. This information along with neutron cross section excitation functions is used to infer the densities of H, C, N and O in the volume sampled. The code we have chosen to use enables us to create very detailed and realistic models of the geometrical configuration of the system, the neutron source and of the detector response. By calculating the signals that will be observed for several configurations and compositions of interrogated object we can investigate and begin to understand how a system that could actually be fielded will perform. Using this modeling capability many early on with substantial savings in time and cost and with improvements in performance. We will present our signal predictions for simple single element test cases and for explosive compositions. From these studies it is dear that the interpretation of the signals from such an explosives identification system will pose a substantial challenge

  5. Multiplicity Analysis during Photon Interrogation of Fissionable Material

    International Nuclear Information System (INIS)

    Clarke, Shaun D.; Pozzi, Sara A.; Padovani, Enrico; Downar, Thomas J.

    2007-01-01

    Simulation of multiplicity distributions with the Monte Carlo method is difficult because each history is treated individually. In order to accurately model the multiplicity distribution, the intensity and time width of the interrogation pulse must be incorporated into the calculation. This behavior dictates how many photons arrive at the target essentially simultaneously. In order to model the pulse width correctly, a Monte Carlo code system consisting of modified versions of the codes MCNPX and MCNP-PoliMi has been developed in conjunction with a post-processing algorithm to operate on the MCNP-PoliMi output file. The purpose of this subroutine is to assemble the interactions into groups corresponding to the number of interactions which would occur during a given pulse. The resulting multiplicity distributions appear more realistic and capture the higher-order multiplets which are a product of multiple reactions occurring during a single accelerator pulse. Plans are underway to gather relevant experimental data to verify and validate the methodology developed and presented here. This capability will enable the simulation of a large number of materials and detector geometries. Analysis of this information will determine the feasibility of using multiplicity distributions as an identification tool for special nuclear material.

  6. La preuve par le nombre

    Directory of Open Access Journals (Sweden)

    Hélène Verdier

    2012-04-01

    Full Text Available S’il en était besoin, la question des usages et de la finalité des résultats de l’inventaire général pourrait être abordée par le nombre : nombre d’œuvres répertoriées, de communes inventoriées, de clichés photographiques réalisés, de dossiers, de consultations des notices dans les bases de données… Les additions aujourd’hui sont éloquentes, mais elles laissent dans l’ombre le rôle de l’inventaire qui, en mettant en œuvre une démarche systématique de connaissance, participe à l’ identificatio...

  7. Par Pond vegetation status Summer 1995 -- Summary

    International Nuclear Information System (INIS)

    Mackey, H.E. Jr.; Riley, R.S.

    1996-01-01

    The water level of Par Pond was lowered approximately 20 feet in mid-1991 in order to protect downstream residents from possible dam failure suggested by subsidence on the downstream slope of the dam and to repair the dam. This lowering exposed both emergent and nonemergent macrophyte beds to drying conditions resulting in extensive losses. A survey of the newly emergent, shoreline aquatic plant communities of Par Pond began in June 1995, three months after the refilling of Par Pond to approximately 200 feet above mean sea level. These surveys continued in July, September, and late October, 1995. Communities similar to the pre-drawdown, Par Pond aquatic plant communities are becoming re-established. Emergent beds of maidencane, lotus, waterlily, and watershield are extensive and well developed. Cattail occurrence continued to increase during the summer, but large beds common to Par Pond prior to the drawdown have not formed. Estimates from SPOT HRV, remote sensing satellite data indicated that as much as 120 hectares of emergent wetlands vegetation may have been present along the Par Pond shoreline by early October, 1995. To track the continued development of macrophytes in Par Pond, future surveys throughout 1996 and 1997, along with the continued evaluation of satellite data to map the areal extent of the macrophyte beds of Par Pond, are planned

  8. Promotion COPERNIC Energy and Society the interrogations on the world demand evolution; Promotion COPERNIC Energie et Societe les interrogations sur l'evolution de la demande mondiale

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-12-15

    In the framework of a prospective reflexion emergence on the energy demand, this document presents an analysis of the prospective approach and of recent studies: challenges, interests, limits, validity of the models and hypothesis and results relevance. With this analysis, the authors aim to identify the main interrogations bond to the world energy demand evolution. They then analyse these interrogations in the framework of a sectoral approach (agriculture, industry, transports, residential) in order to detail the demand and to forecast the evolution. Facing the consumption attitudes, they also suggest some new action avenues to favor a sustainable growth. (A.L.B.)

  9. Enhancing the performance of a tensioned metastable fluid detector based active interrogation system for the detection of SNM in interrogation source in moderated/reflected geometries

    Science.gov (United States)

    Grimes, T. F.; Hagen, A. R.; Archambault, B. C.; Taleyarkhan, R. P.

    2018-03-01

    This paper describes the development of a SNM detection system for interrogating 1m3 cargos via the combination of a D-D neutron interrogation source (with and without reflectors) and tensioned metastable fluid detectors (TMFDs). TMFDs have been previously shown (Taleyarkhan et al., 2008; Grimes et al., 2015; Grimes and Taleyarkhan, 2016; Archambault et al., 2017; Hagen et al., 2016) to be capable of using Threshold Energy Neutron Analysis (TENA) techniques to reject the ∼2.45 MeV D-D interrogating neutrons while still remaining sensitive to >2.45 MeV neutrons resulting from fission in the target (HEU) material. In order to enhance the performance, a paraffin reflector was included around the accelerator head. This reflector was used to direct neutrons into the package to increase the fission signal, lower the energy of the interrogating neutrons to increase the fission cross-section with HEU, and, also to direct interrogating neutrons away from the detectors in order to enhance the required discrimination between interrogating and fission neutrons. Experiments performed with a 239 Pu-Be neutron source and MnO2 indicated that impressive performance gains could be made by placing a parabolic paraffin moderator between the interrogation source and an air-filled cargo container with HEU placed at the center. However, experiments with other cargo fillers (as specified in the well-known ANSI N42.41-2007 report), and with HEU placed in locations other than the center of the package indicated that other reflector geometries might be superior due to over-"focusing" and the increased solid angle effects due to the accommodation of the moderator geometry. The best performance for the worst case of source location and box fill was obtained by placing the reflector only behind the D-D neutron source rather than in front of it. Finally, it was shown that there could be significant gains in the ability to detect concealed SNM by operating the system in multiple geometric

  10. Promotion COPERNIC Energy and Society the interrogations on the world demand evolution; Promotion COPERNIC Energie et Societe les interrogations sur l'evolution de la demande mondiale

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-12-15

    In the framework of a prospective reflexion emergence on the energy demand, this document presents an analysis of the prospective approach and of recent studies: challenges, interests, limits, validity of the models and hypothesis and results relevance. With this analysis, the authors aim to identify the main interrogations bond to the world energy demand evolution. They then analyse these interrogations in the framework of a sectoral approach (agriculture, industry, transports, residential) in order to detail the demand and to forecast the evolution. Facing the consumption attitudes, they also suggest some new action avenues to favor a sustainable growth. (A.L.B.)

  11. Passive neutron interrogation in systems with a poorly characterized detection efficiency

    International Nuclear Information System (INIS)

    Dubi, Chen; Oster, Elad; Ocherashvilli, Aharon; Pedersen, Bent; Hutszy, Janus

    2014-01-01

    Passive neutron interrogation for fissile mass estimation, relying on neutrons coming from spontaneous fission events, is considered a standard NDT procedure in the nuclear safeguard and safety community. Since most structure materials are (relatively) transparent to neutron radiation, passive neutron interrogation is considered highly effective in the analysis of dirty, poorly characterized samples. On the other hand, since a typical passive interrogation assembly is based on 3He detectors, neutrons from additional neutron sources (mainly (α,n) reactions and induced fissions in the tested sample) cannot be separated from the main spontaneous fission source through energetic spectral analysis. There for, applying the passive interrogation methods the implementation of Neutron Multiplicity Counting (NMC) methods for separation between the main fission source and the additional sources. Applying NMC methods requires a well characterized system, in the sense that both system die away time and detection efficiency must be well known (and in particular, independent of the tested sample)

  12. The phase interrogation method for optical fiber sensor by analyzing the fork interference pattern

    Science.gov (United States)

    Lv, Riqing; Qiu, Liqiang; Hu, Haifeng; Meng, Lu; Zhang, Yong

    2018-02-01

    The phase interrogation method for optical fiber sensor is proposed based on the fork interference pattern between the orbital angular momentum beam and plane wave. The variation of interference pattern with phase difference between the two light beams is investigated to realize the phase interrogation. By employing principal component analysis method, the features of the interference pattern can be extracted. Moreover, the experimental system is designed to verify the theoretical analysis, as well as feasibility of phase interrogation. In this work, the Mach-Zehnder interferometer was employed to convert the strain applied on sensing fiber to the phase difference between the reference and measuring paths. This interrogation method is also applicable for the measurements of other physical parameters, which can produce the phase delay in optical fiber. The performance of the system can be further improved by employing highlysensitive materials and fiber structures.

  13. Ultraviolet Raman Spectral Signatures in Support of Lisa (Laser Interrogation of Surface Agents)

    National Research Council Canada - National Science Library

    Sedlacek, III, Arthur J; Finfrock, Charles C; Christesen, Steve; Chyba, Tom; Higdon, Scott

    2003-01-01

    ... (Laser Interrogation of Surface Agents). This engineering, testing and evaluation effort uses a novel mini-Raman lidar technique for on-the-move, short-range, non-contact detection and identification of chemical agents on the battlefield...

  14. Low-Cost Interrogation Technique for Dynamic Measurements with FBG-Based Devices.

    Science.gov (United States)

    Díaz, Camilo A R; Leitão, Cátia; Marques, Carlos A; Domingues, M Fátima; Alberto, Nélia; Pontes, Maria José; Frizera, Anselmo; Ribeiro, Moisés R N; André, Paulo S B; Antunes, Paulo F C

    2017-10-23

    Fiber Bragg gratings are widely used optical fiber sensors for measuring temperature and/or mechanical strain. Nevertheless, the high cost of the interrogation systems is the most important drawback for their large commercial application. In this work, an in-line Fabry-Perot interferometer based edge filter is explored in the interrogation of fiber Bragg grating dynamic measurements up to 5 kHz. Two devices an accelerometer and an arterial pulse wave probe were interrogated with the developed approach and the results were compared with a commercial interrogation monitor. The data obtained with the edge filter are in agreement with the commercial device, with a maximum RMSE of 0.05 being able to meet the requirements of the measurements. Resolutions of 3.6 pm and 2.4 pm were obtained, using the optical accelerometer and the arterial pulse wave probe, respectively.

  15. Pulsed THZ Interrogation of Sofi With Knit Lines in 2D

    National Research Council Canada - National Science Library

    Banks, H. T; Gibson, N. L; Winfree, W. P

    2006-01-01

    This paper examines the scattering effect of knit lines and voids in SOFI through simulations of THz interrogation at normal and non-normal angles of incidence and using focused and non-focused single-cycle plane waves...

  16. The History of MIS-Y: U.S. Strategic Interrogation During World War II

    National Research Council Canada - National Science Library

    Kleinman, Steven M

    2002-01-01

    As World War II unfolded, the strategic interrogation programs established by the British, German, and American forces evolved into robust collection entities that proved to be a unique source of critical intelligence...

  17. Adaptive image interrogation for PIV : Application to compressible flows and interfaces

    NARCIS (Netherlands)

    Theunissen, R.

    2010-01-01

    As an experimental tool, Particle Image Velocimetry has quickly superseded traditional point-wise measurements. The inherent image processing has become standardized though the performances are strongly dependent on user experience. Moreover, the arduously selected image interrogation parameters are

  18. Intelligence, previous convictions and interrogative suggestibility: a path analysis of alleged false-confession cases.

    Science.gov (United States)

    Sharrock, R; Gudjonsson, G H

    1993-05-01

    The main purpose of this study was to investigate the relationship between interrogative suggestibility and previous convictions among 108 defendants in criminal trials, using a path analysis technique. It was hypothesized that previous convictions, which may provide defendants with interrogative experiences, would correlate negatively with 'shift' as measured by the Gudjonsson Suggestibility Scale (Gudjonsson, 1984a), after intelligence and memory had been controlled for. The hypothesis was partially confirmed and the theoretical and practical implications of the findings are discussed.

  19. Interrogating the topological robustness of gene regulatory circuits by randomization.

    Directory of Open Access Journals (Sweden)

    Bin Huang

    2017-03-01

    Full Text Available One of the most important roles of cells is performing their cellular tasks properly for survival. Cells usually achieve robust functionality, for example, cell-fate decision-making and signal transduction, through multiple layers of regulation involving many genes. Despite the combinatorial complexity of gene regulation, its quantitative behavior has been typically studied on the basis of experimentally verified core gene regulatory circuitry, composed of a small set of important elements. It is still unclear how such a core circuit operates in the presence of many other regulatory molecules and in a crowded and noisy cellular environment. Here we report a new computational method, named random circuit perturbation (RACIPE, for interrogating the robust dynamical behavior of a gene regulatory circuit even without accurate measurements of circuit kinetic parameters. RACIPE generates an ensemble of random kinetic models corresponding to a fixed circuit topology, and utilizes statistical tools to identify generic properties of the circuit. By applying RACIPE to simple toggle-switch-like motifs, we observed that the stable states of all models converge to experimentally observed gene state clusters even when the parameters are strongly perturbed. RACIPE was further applied to a proposed 22-gene network of the Epithelial-to-Mesenchymal Transition (EMT, from which we identified four experimentally observed gene states, including the states that are associated with two different types of hybrid Epithelial/Mesenchymal phenotypes. Our results suggest that dynamics of a gene circuit is mainly determined by its topology, not by detailed circuit parameters. Our work provides a theoretical foundation for circuit-based systems biology modeling. We anticipate RACIPE to be a powerful tool to predict and decode circuit design principles in an unbiased manner, and to quantitatively evaluate the robustness and heterogeneity of gene expression.

  20. Epistemic interrogatives in events anchored in the temporal anteriority

    Directory of Open Access Journals (Sweden)

    Vesela Chergova

    2012-12-01

    Full Text Available The present study attempts to analyse the epistemic modal functionality of temporal posteriority grammemes, referred to the “non-inactual plan”, i. e. the discourse plan measured directly from the moment of enunciation. In our opinion, the invariant category values of a verbal grameme predetermine the development of their complementary and contextual functions. Therefore, the analysis focuses also on the oppositional relations and neutralizations between the categories of verb tense, plan and perspective, on the temporal semantics and the aspectual values which maintain the oppositions between the nominal forms of the verb in accordance with the interpretation of verb categories proposed by Coseriu (1976. In this particular case, the complementary values which outline the scope of our interest fall into the parameters of the possibility and the probability (Veiga, 1991; Kitova-Vasileva, 2000, i.e. conjecture and conclusion in the field of epistemic semantics, yet with an orientation to the temporal anteriority epoch i.e. there is a conjecture regarding actions marked as prior to the moment of enunciation. The syntactic realisation of the epistemic values of conjecture is outlined in the sentence patterns of epistemic interrogatives of the type [Será que + V(P.P.S.] and [Ter(F.S. do Ind.+ V(Part.Pass.]. The study in this way goes beyond the semantic interpretation of the modal, temporal and aspectual values of the morphological instruments of conjecture, and follows the syntactic structure (the modus–dictum relations also in its discourse and pragmatic value.

  1. Massively Parallel Interrogation of Aptamer Sequence, Structure and Function

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, N O; Tok, J B; Tarasow, T M

    2008-02-08

    Optimization of high affinity reagents is a significant bottleneck in medicine and the life sciences. The ability to synthetically create thousands of permutations of a lead high-affinity reagent and survey the properties of individual permutations in parallel could potentially relieve this bottleneck. Aptamers are single stranded oligonucleotides affinity reagents isolated by in vitro selection processes and as a class have been shown to bind a wide variety of target molecules. Methodology/Principal Findings. High density DNA microarray technology was used to synthesize, in situ, arrays of approximately 3,900 aptamer sequence permutations in triplicate. These sequences were interrogated on-chip for their ability to bind the fluorescently-labeled cognate target, immunoglobulin E, resulting in the parallel execution of thousands of experiments. Fluorescence intensity at each array feature was well resolved and shown to be a function of the sequence present. The data demonstrated high intra- and interchip correlation between the same features as well as among the sequence triplicates within a single array. Consistent with aptamer mediated IgE binding, fluorescence intensity correlated strongly with specific aptamer sequences and the concentration of IgE applied to the array. The massively parallel sequence-function analyses provided by this approach confirmed the importance of a consensus sequence found in all 21 of the original IgE aptamer sequences and support a common stem:loop structure as being the secondary structure underlying IgE binding. The microarray application, data and results presented illustrate an efficient, high information content approach to optimizing aptamer function. It also provides a foundation from which to better understand and manipulate this important class of high affinity biomolecules.

  2. Interrogating resilience: toward a typology to improve its operationalization

    Directory of Open Access Journals (Sweden)

    Julie L. Davidson

    2016-06-01

    Full Text Available In the context of accelerated global change, the concept of resilience, with its roots in ecological theory and complex adaptive systems, has emerged as the favored framework for understanding and responding to the dynamics of change. Its transfer from ecological to social contexts, however, has led to the concept being interpreted in multiple ways across numerous disciplines causing significant challenges for its practical application. The aim of this paper is to improve conceptual clarity within resilience thinking so that resilience can be interpreted and articulated in ways that enhance its utility and explanatory power, not only theoretically but also operationally. We argue that the current confusion and ambiguity within resilience thinking is problematic for operationalizing the concept within policy making. To achieve our aim, we interrogate resilience interpretations used within a number of academic and practice domains in the forefront of contending with the disruptive and sometimes catastrophic effects of global change (primarily due to climate change on ecological and human-nature systems. We demonstrate evolution and convergence among disciplines in the interpretations and theoretical underpinnings of resilience and in engagement with cross-scale considerations. From our analysis, we identify core conceptual elements to be considered in policy responses if resilience is to fulfill its potential in improving decision making for change. We offer an original classification of resilience definitions in current use and a typology of resilience interpretations. We conclude that resilience thinking must be open to alternative traditions and interpretations if it is to become a theoretically and operationally powerful paradigm.

  3. The interrogative particle zar - from syntax and semantics to etymology

    Directory of Open Access Journals (Sweden)

    Vlajić-Popović Jasna B.

    2016-01-01

    Full Text Available This paper deals with the Serbian interrogative particle zar/zar/zar ‘num, forsan’, typically positioned at the beginning of a sentence (expressing surprise, wonder, disbelief, dissent, etc. or at its end, coupled with ne and separated by a comma (in guided questions, affirmative and negative alike: Ti ga (ne voliš, zar ne?, yet also broadly attested in obsolete use (in the 19-20th-century literature in modal function, where it is synonymous to valjda, možda ‘perhaps, maybe’. After a review of the ways zar is treated in modern Serbian grammars and descriptive dictionaries (including several dialectal dictionaries, and following research of Macedonian, Bulgarian and Turkish dictionaries, its etymology is discussed: Skok’s unconvincing idioglottal interpretation is refuted, and Rešetar’s idea is reintroduced (prevoiusly rejected by Skok, questioned by Elezović, accepted in the RJA that zar, along with its obliterated forms zaer, zajer, zaher, should be traced back to Turkish zahir adv. ‘apparently, clearly, evidently’, ‘seemingly, perhaps, maybe’. The semantic-syntactic evolution of the loanword within the Serbian language is illustrated, and hence the alloglottal etymology corroborated, by a selection of quotes from folklore and eminent 19-20th-century writers. And finally, as the most likely, the paper offers the interpretation of this particle as a hybrid formation resulting from contamination by the Turkisms of an idioglottal zar, which could be related to archaic Polish zaż < PSl. *za-že. [Projekat Ministarstva nauke Republike Srbije, br. 178007: Etimološka istraživanja srpskog jezika i izrada Etimološkog rečnika srpskog jezika

  4. Toward multi-area distributed network of implanted neural interrogators

    Science.gov (United States)

    Powell, Marc P.; Hou, Xiaoxiao; Galligan, Craig; Ashe, Jeffrey; Borton, David A.

    2017-08-01

    As we aim to improve our understanding of the brain, it is critical that researchers have simultaneous multi-area, large-scale access to the brain. Information processing in the brain occurs through close and distant coupling of functional sub-domains, as opposed to within isolated single neurons. However, commercially available neural interfaces capable of sensing electrophysiology of single neurons, currently allow access to only a small, mm3 volume of cortical cells, are not scalable to recording from orders of magnitude more neurons, and leverage bulky, skull mounted hardware and cabling sensitive to relative movements of the skull and brain. In this work, we propose a system capable of recording from many individual distributed neural interrogator nodes, untethered from any external electronics. Using an array of epidural inductive coils to wirelessly power the implanted electronics, the system is intended to be agnostic to the surgical placement of any individual node. Here, we demonstrate the ability to transmit nearly 15mW of power with greater than 50% power transfer efficiency, benchtop testing of individual subcircuit system components showing successful digitization of neural signals, and wireless transmission currently supporting a data rate of 3.84Mbps. We leverage a software defined radio based RF receiver to demodulate the data which can be stored in memory for later retrieval. Finally, we introduce a packaging technology capable of isolating active electronics from the surrounding tissue while providing capability for electrical feed-through assemblies for external neural interfacing. We expect, based on the presented preliminary findings, that the system can be integrated into a platform technology for the study of the intricate interactions between cortical domains.

  5. Massively parallel interrogation of aptamer sequence, structure and function.

    Directory of Open Access Journals (Sweden)

    Nicholas O Fischer

    Full Text Available BACKGROUND: Optimization of high affinity reagents is a significant bottleneck in medicine and the life sciences. The ability to synthetically create thousands of permutations of a lead high-affinity reagent and survey the properties of individual permutations in parallel could potentially relieve this bottleneck. Aptamers are single stranded oligonucleotides affinity reagents isolated by in vitro selection processes and as a class have been shown to bind a wide variety of target molecules. METHODOLOGY/PRINCIPAL FINDINGS: High density DNA microarray technology was used to synthesize, in situ, arrays of approximately 3,900 aptamer sequence permutations in triplicate. These sequences were interrogated on-chip for their ability to bind the fluorescently-labeled cognate target, immunoglobulin E, resulting in the parallel execution of thousands of experiments. Fluorescence intensity at each array feature was well resolved and shown to be a function of the sequence present. The data demonstrated high intra- and inter-chip correlation between the same features as well as among the sequence triplicates within a single array. Consistent with aptamer mediated IgE binding, fluorescence intensity correlated strongly with specific aptamer sequences and the concentration of IgE applied to the array. CONCLUSION AND SIGNIFICANCE: The massively parallel sequence-function analyses provided by this approach confirmed the importance of a consensus sequence found in all 21 of the original IgE aptamer sequences and support a common stem:loop structure as being the secondary structure underlying IgE binding. The microarray application, data and results presented illustrate an efficient, high information content approach to optimizing aptamer function. It also provides a foundation from which to better understand and manipulate this important class of high affinity biomolecules.

  6. Battery-less wireless interrogation of microstrip patch antenna for strain sensing

    International Nuclear Information System (INIS)

    Xu, X; Huang, H

    2012-01-01

    This paper presents a battery-less wireless interrogation system that can measure the resonant frequency of a microstrip patch antenna with a fine resolution. Since the antenna resonant frequency is sensitive to strain-induced deformations, wireless interrogation of the antenna sensor for strain measurement was demonstrated. By implementing a microwatt impedance switching circuit at the sensor node, the antenna backscattering is amplitude modulated at the sensor node so that it can be separated from the structural backscattering at the interrogator. The sensor node can be powered by a small photocell and thus achieve battery-less operation. The operating principle of the wireless interrogation system is first described, followed by the implementation and characterization of the wireless interrogation system. The antenna resonant frequency shifts were correlated to the applied strains through a static tensile experiment. An excellent agreement between the experimental results and the analytical prediction was obtained. A power transmission model was established and validated with experimental measurements. Based on this power transmission model, we estimated that the maximum interrogation distance of the wireless strain measurement system is 26 m. (paper)

  7. Disposal of the radioactive effluents at the 'Commissariat a l'Energie Atomique'. Treatment leading to evacuation into a river; Probleme du rejet des residus radioactifs liquides au CEA. Traitements aboutissant a des rejets en riviere

    Energy Technology Data Exchange (ETDEWEB)

    Duhamel; Menoux; Candillon [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    to find out in loaded water, 10) Impot elements other than Sr{sup 90} are also studied. (author) [French] Le probleme du traitement des residus radioactifs liquides au CEA est envisage sous l'angle du rejet ultime en riviere dans des conditions optima permettant de satisfaire aux Normes de la protection. 2) A Saclay, ou l'on ne dispose que d'un etang ou l'eau ne se renouvelle pas, les liquides epures sont envoyes par camion citerne a Fontenay-aux-Roses, ou ils sont deverses provisoirement - dans les egouts - en attendant qu'un point de rejet en Seine ait ete determine. 3) Au Bouchet, les eaux residuaires de l'Usine de traitement de minerais d'urano-thorianite devront etre traitees en deux temps de facon a separer le radium dans une premiere phase, ce qui facilitera l'epuration au cours de la deuxieme phase. 4) En vue des futurs rejets a Marcoule, une etude a ete conduite a Saclay, sur des effluents synthetiques - type Marcoule - ayant pour but de mettre au point des procedes d'elimination selective du Sr d'une part, du Cs d'autre part, par coprecipitation. 5) Dans le cas general du rejet ultime en riviere, les problemes suivants sont successivement envisages: - predilution entre les bassins de stockage des eaux epurees et le fleuve; - mode d'injection dans le fleuve; - dilution dans le fleuve (etude prealable par traceurs); - evolution de l'activite dans les eaux du fleuve (adsorption par les organismes inertes ou vivants, contamination des berges); - incidence sur le choix d'un site; - dilution isotopique. 6) Ce dernier probleme est specialement detaille. 7) La teneur de l'eau en un element donne conditionne la dilution isotopique de son isotope radioactif. L'analyse decelant une carence, il est possible d'y suppleer par des rejets d'isotope stable. 8) Cette methode conduit en certains cas a des analyses delicates (en particulier dans le cas du {sup 90}Sr), la teneur en isotope

  8. ¡París!

    Directory of Open Access Journals (Sweden)

    Beatriz Caballero

    2003-01-01

    Full Text Available El día no le alcanzaba para caminarlo. Conocía cada puente, cada calle,plaza, museo, rincón, iglesia, café, y la mesa con el mejor ángulo para mirar siempre una iglesia, ojalá Saint-Germain-des-Pres, o Notre-Dame. Siempre contaba la impresión que le había causado a Bolívar ver allí cuando el papa coronó a Napoleón. Él se iba para la oficina todos los días, Luis a un taller a pintar, Antonio a estudiar ciencias políticas, yo al colegio y mamá hacía las cosas prácticas. Aprendíamos francés todos al tiempo y por la noche nos contábamos lo nuevo que cada uno había aprendido. Mamá después, cuando ya se quería volver, decía que París nos había maleado a todos. Estaba en pleno furor el cine francés de la "nueva ola", pero ella sólo me llevaba a ver películas de vaqueros pues no se fiaba de la clasificación de los periódicos.

  9. Methods for Characterization of Batteries Using Acoustic Interrogation

    Science.gov (United States)

    Bhadra, Shoham

    Batteries are a ubiquitous form of electrochemical energy storage, but thus far the methods for measuring the mechanical properties of batteries and their component materials in operando have lagged far behind the methods for measuring the corresponding electrical properties. In this thesis, I demonstrate methods for determining the changes in materials properties of an electrochemical energy storage cell both ex situ and in operando.. I begin by establishing the impact of micro-scale morphology changes on the macro-scale dynamic mechanical response in commercial alkaline AA cells. Using a bounce test, the coefficient of restitution (COR) of the cell is shown to increase non-linearly as a function of state of charge (SOC). I show that the reason for the increase in the COR stems from the spatially-dependent oxidation of the Zn anode, with an initial increase corresponding to the formation of a percolation pathway of ZnO-clad Zn particles spanning the radius of the anode. The subsequent saturation of the COR is shown to result from the ultimate solidification and desiccation of the Zn anode. Building from this, I present a generalized in operando solution for materials characterization in batteries using ultrasonic interrogation. The materials properties of battery components change during charge and discharge, resulting in a change in the sound speed of the materials. By attaching transducers to a battery during cycling and sending ultrasonic pulses through each cell I observe the changes in the time of flight (ToF) of the pulses, both in reflection and transmission. I show that the changes in ToF correspond to both SOC and state of health (SOH) in a variety of battery chemistries and geometries, and detail a corresponding acoustic conservation law model framework. Finally, I perform these electrochemical acoustic time of flight (EAToF) experiments on commercial alkaline AA cells. By correlating the results with energy dispersive x-ray diffraction (EDXRD) data and

  10. FY09 Advanced Instrumentation and Active Interrogation Research for Safeguards

    International Nuclear Information System (INIS)

    Chichester, D.L.; Pozzi, S.A.; Seabury, E.H.; Dolan, J.L.; Flaska, M.; Johnson, J.T.; Watson, S.M.; Wharton, J.

    2009-01-01

    Multiple small-scale projects have been undertaken to investigate advanced instrumentation solutions for safeguard measurement challenges associated with advanced fuel cycle facilities and next-generation fuel reprocessing installations. These activities are in support of the U.S. Department of Energy's Fuel Cycle Research and Development program and its Materials Protection, Accounting, and Control for Transmutation (MPACT) campaign. (1) Work was performed in a collaboration with the University of Michigan (Prof. Sara Pozzi, co-PI) to investigate the use of liquid-scintillator radiation detectors for assaying mixed-oxide (MOX) fuel, to characterize its composition and to develop advanced digital pulse-shape discrimination algorithms for performing time-correlation measurements in the MOX fuel environment. This work included both simulations and experiments and has shown that these techniques may provide a valuable approach for use within advanced safeguard measurement scenarios. (2) Work was conducted in a collaboration with Oak Ridge National Laboratory (Dr. Paul Hausladen, co-PI) to evaluate the strengths and weaknesses of the fast-neutron coded-aperture imaging technique for locating and characterizing fissile material, and as a tool for performing hold-up measurements in fissile material handling facilities. This work involved experiments at Idaho National Laboratory, using MOX fuel and uranium metal, in both passive and active interrogation configurations. A complete analysis has not yet been completed but preliminary results suggest several potential uses for the fast neutron imaging technique. (3) Work was carried out to identify measurement approaches for determining nitric acid concentration in the range of 1-4 M and beyond. This work included laboratory measurements to investigate the suitability of prompt-gamma neutron activation analysis for this measurement and product reviews of other commercial solutions. Ultrasonic density analysis appears to be

  11. A rapid method of dosing plutonium in radioactive effluents; Methode de dosage rapide du plutonium dans les effluents radioactifs (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Scheidhauer, J; Messainguiral, L [Commissariat a l' Energie Atomique, Centre de Production de Plutonium, Marcoule (France). Centre d' Etudes Nucleaires

    1961-07-01

    The plutonium is first separated by a lanthanum fluoride precipitation. The precipitated fluorides are dissolved in normal nitric acid solution in the presence of aluminium nitrate. The plutonium transformed to the tetravalent state is then extracted with thenoyltrifluoroacetone and returned to the aqueous phase with 10 N nitric acid. After evaporation on a watch glass the residue is calcined on a Meker burner and counted using a counting system fitted with a zinc sulphide scintillator. When necessary, the calcium is eliminated at the beginning of the dosage by a fluoride precipitation, the plutonium being oxidised to the valency IV. (authors) [French] Le plutonium est d'abord separe par entrainement au fluorure de lanthane. Le precipite des fluorures est remis en solution en milieu acide nitrique normal, en presence de nitrate d'aluminium. Le plutonium amene a la valence IV est alors extrait par la thenoyltrifluoroacetone et remis en phase aqueuse dans l'acide nitrique 10 N. Apres evaporation sur verre de montre, le residu est calcine sur bec Meker et compte sur un ensemble de comptage equipe d'un scintillateur au sulfure de zinc. Lorsque cela est necessaire, le calcium est elimine, au debut du dosage, par precipitation du fluorure, le plutonium etant oxyde a la valence VI. (auteurs)

  12. C9.A/14 steelwork joints de poutres par plaque frontale : assemblages par gousset

    CERN Document Server

    2015-01-01

    Les Tables de résistances ultimes des assemblages boulonnés par plaque frontale et par gousset, complétées par une description des modèles de calcul et des exemples d’application, ont pour but de faciliter la tâche de l'ingénieur et du constructeur. Cette première partie C9.A/14 contient les chapitres suivants: - Joints de poutres par plaque frontale en acier S235 et S355 - Assemblages par gousset en acier S235 et S355 Les Tables contiennent des données relatives à la géométrie ainsi que les valeurs de calcul correspondantes des résistances ultimes des assemblages ; elles remplacent le chapitre « Assemblages par plaques frontales et boulons HR » des anciennes Tables C9.1 de 1983 / 2002. Le calcul de ces assemblages par plaque frontale est basé sur les hypothèses du modèle de la méthode des composants décrite dans la norme SN EN 1993-1-8. Les vérifications sont effectuées selon la norme SIA 263:2013. Les assemblages par gousset remplacent les assemblages par double cornière, (telle...

  13. The Hydrographical Features of the Baltic Sea and the Disposal of Radioactive Wastes; L'Hydrographie de la Mer Baltique et l'Evacuation des Dechets Radioactifs; 0413 0418 0414 0420 041e 0413 0420 0414 ; Caracteristicas Hidrograficas del Mar Baltico en Relacion con la Evacuacion de Desechos Radiactivos

    Energy Technology Data Exchange (ETDEWEB)

    Hela, Ilmo [Institute of Marine Research Helsinki (Finland)

    1960-07-01

    The purpose of the paper is to point out a few hydrographical features of the Baltic Sea, which make this sea, in reference to the disposal of radioactive wastes, different from any oceanic region. The seas can be divided, in reference to the practical problem of the disposal of radionuclides, into the following zones: (1) harbours, (2) fairways leading into harbours, (3) outer continental shelf and (4) the open sea. There, is no open sea, in the above sense, in the Baltic Sea. In addition, the validity of the rules recommended for the above zones, must be carefully checked through further hydrographical studies, since: (1) the whole Baltic is, in a sense, an estuary, with a sill-depth of only 18 metres in the Danish Sounds, (2) the mixing in the Baltic Sea is much more restricted than in the oceans, since the Baltic is rich in islands, brackish, heavily stratified, practically tideless, in winter partly covered with ice, and has a limited fetch of wind and only slowly moving permanent currents. In the paper reference is made to all these factors which diminish the turbulent diffusion, both vertical and horizontal. For the evaluation of the advection and turbulent (eddy) diffusion, both in the upper water layers and at the bottom, synoptic observations of current velocity and salinity at a number of points in several regions of the Baltic Sea and under different weather conditions are needed. (author) [French] Le memoire a pour but d'exposer certains traits de l'hydrographie de la mer Baltique qui, du point de vue de l'evacuation des dechets radioactifs, la distinguent de toute region oceanique. Pour l'etude des problemes pratiques poses par l'evacuation des dechets radioactifs, on peut repartir la mer en quatre zones: 1) les ports, 2) les chenaux d'acces aux ports, 3) le plateau continental, 4) la haute mer. Dans ce sens, il n'y a pas de haute mer dans la Baltique. En outre, la validite des reglements recommandes pour les zones precitees doit faire l'objet d

  14. Use of radioactive tracers in studying the transport of solids in watercourses; Emploi de traceurs radioactifs pour l'etude du transport solide dans les cours d'eau; Ispol'zovanie radioaktivnykh indikatorov dlya izucheniya peremeshcheniya tverdykh chastits v vodnykh potokakh; Empleo de indicadores radiactivos para el estudio del transporte de solidos en las corrientes de agua

    Energy Technology Data Exchange (ETDEWEB)

    Courtois, G [Centre d' Etudes Nucleaires de Saclay (France); Jaeery, P; Heuzel, M [Laboratoire National d' Hydraulique de Chatou (France)

    1962-01-15

    The National Hydraulics Laboratory which, in collaboration with the Saclay Nuclear Research Centre, has for several years been devising equipment and techniques for the study of sediment movements by the radioactive tracer method, is now endeavouring to develop a really quantitative method of research. Two river experiments were recently made, the first a study of shingle drifting in the Rhone, the second a study of sand movement in the Niger. The latter experiment was matched by identical experiments carried out on a scale model of the River Niger which the Chatou Laboratory has at its disposal. The experiments used Mn{sup 56} and Na{sup 24} radiation obtained by direct activation of crushed apricot stone, this representing in the scale model the natural sediment of the Niger bed. The Chatou Laboratory and the Saclay Nuclear Study Centre are at present both devoting attention to the application of radioactive tracers in studies with scale models, with the twin aims of: (a) Obtaining a single research tool for use under natural conditions and with scale models in order to gauge the trustworthiness of the model, in the calibration testing stage; (b) Taking advantage of the facilities for direct observation and measurement offered by scale models in order to study prospects of improving the tracer method, with a view particularly to securing quantitative data. (author) [French] Le Laboratoire national d'hydraulique, qui depuis quelques annees a developpe, en collaboration avec le Centre d'etudes nucleaires de Saclay, les appareillages et les techniques d'etudes des mouvements de sediments par la methode des traceurs radioactifs, s'efforce actuellement de mettre au point un moyen d'investigation veritablement quantitatif. Deux experiences ont ete effectuees recemment en riviere, la premiere a ete consacree a l'etude du charriage des galets dans le Rhone, l'autre a l'etude des transports de sables dans le Niger. Cette derniere experience a ete doublee d

  15. Active-interrogation measurements of fast neutrons from induced fission in low-enriched uranium

    International Nuclear Information System (INIS)

    Dolan, J.L.; Marcath, M.J.; Flaska, M.; Pozzi, S.A.; Chichester, D.L.; Tomanin, A.; Peerani, P.

    2014-01-01

    A detection system was designed with MCNPX-PoliMi to measure induced-fission neutrons from U-235 and U-238 using active interrogation. Measurements were then performed with this system at the Joint Research Centre in Ispra, Italy on low-enriched uranium samples. Liquid scintillators measured induced fission neutrons to characterize the samples in terms of their uranium mass and enrichment. Results are presented to investigate and support the use of organic liquid scintillators with active interrogation techniques to characterize uranium containing materials. -- Highlights: • We studied low-enriched uranium using active-interrogation experiments including a deuterium–tritium neutron generator and an americium–lithium isotopic neutron source. • Liquid scintillators measured induced-fission neutrons from the active-interrogation methods. • Fast-neutron (DT) and thermal-neutron (Am–Li) interrogation resulted in the measurement of trends in uranium mass and 235 U enrichment respectively. • MCNPX-PoliMi, the Monte Carlo transport code, simulated the measured induced-fission neutron trends in the liquid scintillators

  16. Scalable interrogation: Eliciting human pheromone responses to deception in a security interview setting.

    Science.gov (United States)

    Stedmon, Alex W; Eachus, Peter; Baillie, Les; Tallis, Huw; Donkor, Richard; Edlin-White, Robert; Bracewell, Robert

    2015-03-01

    Individuals trying to conceal knowledge from interrogators are likely to experience raised levels of stress that can manifest itself across biological, physiological, psychological and behavioural factors, providing an opportunity for detection. Using established research paradigms an innovative scalable interrogation was designed in which participants were given a 'token' that represented information they had to conceal from interviewers. A control group did not receive a token and therefore did not have to deceive the investigators. The aim of this investigation was to examine differences between deceivers and truth-tellers across the four factors by collecting data for cortisol levels, sweat samples, heart-rate, respiration, skin temperature, subjective stress ratings and video and audio recordings. The results provided an integrated understanding of responses to interrogation by those actively concealing information and those acting innocently. Of particular importance, the results also suggest, for the first time in an interrogation setting, that stressed individuals may secrete a volatile steroid based marker that could be used for stand-off detection. The findings are discussed in relation to developing a scalable interrogation protocol for future research in this area. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  17. Ultrafast Fiber Bragg Grating Interrogation for Sensing in Detonation and Shock Wave Experiments.

    Science.gov (United States)

    Rodriguez, George; Gilbertson, Steve M

    2017-01-27

    Chirped fiber Bragg grating (CFBG) sensors coupled to high speed interrogation systems are described as robust diagnostic approaches to monitoring shock wave and detonation front propagation tracking events for use in high energy density shock physics applications. Taking advantage of the linear distributed spatial encoding of the spectral band in single-mode CFBGs, embedded fiber systems and associated photonic interrogation methodologies are shown as an effective approach to sensing shock and detonation-driven loading processes along the CFBG length. Two approaches, one that detects spectral changes in the integrated spectrum of the CFBG and another coherent pulse interrogation approach that fully resolves its spectral response, shows that 100-MHz-1-GHz interrogation rates are possible with spatial resolution along the CFBG in the 50 µm to sub-millimeter range depending on the combination of CFBG parameters (i.e., length, chirp rate, spectrum) and interrogator design specifics. Results from several dynamic tests are used to demonstrate the performance of these high speed systems for shock and detonation propagation tracking under strong and weak shock pressure loading: (1) linear detonation front tracking in the plastic bonded explosive (PBX) PBX-9501; (2) tracking of radial decaying shock with crossover to non-destructive CFBG response; (3) shock wave tracking along an aluminum cylinder wall under weak loading accompanied by dynamic strain effects in the CFBG sensor.

  18. Active-interrogation measurements of fast neutrons from induced fission in low-enriched uranium

    Energy Technology Data Exchange (ETDEWEB)

    Dolan, J.L., E-mail: jldolan@umich.edu [Department of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI 48109 (United States); Marcath, M.J.; Flaska, M.; Pozzi, S.A. [Department of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI 48109 (United States); Chichester, D.L. [Idaho National Laboratory, Idaho Falls, ID 83415 (United States); Tomanin, A.; Peerani, P. [European Commission, Joint Research Centre, Institute for Transuranium Elements, Ispra (Italy)

    2014-02-21

    A detection system was designed with MCNPX-PoliMi to measure induced-fission neutrons from U-235 and U-238 using active interrogation. Measurements were then performed with this system at the Joint Research Centre in Ispra, Italy on low-enriched uranium samples. Liquid scintillators measured induced fission neutrons to characterize the samples in terms of their uranium mass and enrichment. Results are presented to investigate and support the use of organic liquid scintillators with active interrogation techniques to characterize uranium containing materials. -- Highlights: • We studied low-enriched uranium using active-interrogation experiments including a deuterium–tritium neutron generator and an americium–lithium isotopic neutron source. • Liquid scintillators measured induced-fission neutrons from the active-interrogation methods. • Fast-neutron (DT) and thermal-neutron (Am–Li) interrogation resulted in the measurement of trends in uranium mass and {sup 235}U enrichment respectively. • MCNPX-PoliMi, the Monte Carlo transport code, simulated the measured induced-fission neutron trends in the liquid scintillators.

  19. Progress in miniaturization of a multichannel optical fiber Bragg grating sensor interrogator

    Science.gov (United States)

    Lopatin, Craig M.; Mahmood, Shah; Mendoza, Edgar; Moslehi, Behzad; Black, Richard; Chau, Kelvin; Oblea, Levy

    2007-07-01

    An effort to develop a miniaturized multichannel optical fiber Bragg grating sensor interrogator was initiated in 2006 under the Small Business Innovative Research (SBIR) program. The goal was to develop an interrogator that would be sufficiently small and light to be incorporated into a health monitoring system for use on tactical missiles. Two companies, Intelligent Fiber Optic Systems Corporation (IFOS) and Redondo Optics, were funded in Phase I, and this paper describes the prototype interrogators that were developed. The two companies took very different approaches: IFOS focused on developing a unit that would have a high channel count and high resolution, using off-the-shelf components, while Redondo Optics chose to develop a unit that would be very small and lightweight, using custom designed integrated optical chips. It is believed that both approaches will result in interrogators that will be significantly small, lighter, and possibly even more precise than what is currently commercially available. This paper will also briefly describe some of the sensing concepts that may be used to interrogate the health of the solid rocket motors used in many missile systems. The sponsor of this program was NAVAIR PMA 280.

  20. Sequential interrogation of multiple FBG sensors using LPG modulation and an artificial neural network

    International Nuclear Information System (INIS)

    Basu, Mainak; Ghorai, S K

    2015-01-01

    Interrogating multiple fiber Bragg gratings (FBG) requires highly sensitive spectrum scanning equipment such as optical spectrum analyzers, tunable filters, acousto-optic tunable filters etc, which are expensive, bulky and time consuming. In this paper, we present a new approach for multiple FBG sensor interrogation using long-period gratings and an artificial neural network. The reflection spectra of the multiplexed FBGs are modulated by two long period gratings separately and the modulated optical intensities were detected by two photodetectors. The outputs of the detectors are then used as input in a previously trained artificial neural network to interrogate the FBG sensors. Simulations have been performed to determine the strain and wavelength shift using two and four sensors. The interrogation system has also been demonstrated experimentally for two sensors using simply supported beams in the range of 0–350 μstrain. The proposed interrogation scheme has been found to identify the perturbed FBG, and to determine strain and wavelength shift with reasonable accuracy. (paper)

  1. Narrowband interrogation of plasmonic optical fiber biosensors based on spectral combs

    Science.gov (United States)

    González-Vila, Álvaro; Kinet, Damien; Mégret, Patrice; Caucheteur, Christophe

    2017-11-01

    Gold-coated tilted fiber Bragg gratings can probe surface Plasmon polaritons with high resolution and sensitivity. In this work, we report two configurations to interrogate such plasmonic biosensors, with the aim of providing more efficient alternatives to the widespread spectrometer-based techniques. To this aim, the interrogation is based on measuring the optical power evolution of the cladding modes with respect to surrounding refractive index changes instead of computing their wavelength shift. Both setups are composed of a broadband source and a photodiode and enable a narrowband interrogation around the cladding mode that excites the surface Plasmon resonance. The first configuration makes use of a uniform fiber Bragg grating to filter the broadband response of the source in a way that the final interrogation is based on an intensity modulation measured in transmission. The second setup uses a uniform fiber grating too, but located beyond the sensor and acting as a selective optical mirror, so the interrogation is carried out in reflection. Both configurations are compared, showing interesting differential features. The first one exhibits a very high sensitivity while the second one has an almost temperature-insensitive behavior. Hence, the choice of the most appropriate method will be driven by the requirements of the target application.

  2. Magnetic Nanotweezers for Interrogating Biological Processes in Space and Time.

    Science.gov (United States)

    Kim, Ji-Wook; Jeong, Hee-Kyung; Southard, Kaden M; Jun, Young-Wook; Cheon, Jinwoo

    2018-04-17

    The ability to sense and manipulate the state of biological systems has been extensively advanced during the past decade with the help of recent developments in physical tools. Unlike standard genetic and pharmacological perturbation techniques-knockdown, overexpression, small molecule inhibition-that provide a basic on/off switching capability, these physical tools provide the capacity to control the spatial, temporal, and mechanical properties of the biological targets. Among the various physical cues, magnetism offers distinct advantages over light or electricity. Magnetic fields freely penetrate biological tissues and are already used for clinical applications. As one of the unique features, magnetic fields can be transformed into mechanical stimuli which can serve as a cue in regulating biological processes. However, their biological applications have been limited due to a lack of high-performance magnetism-to-mechanical force transducers with advanced spatiotemporal capabilities. In this Account, we present recent developments in magnetic nanotweezers (MNTs) as a useful tool for interrogating the spatiotemporal control of cells in living tissue. MNTs are composed of force-generating magnetic nanoparticles and field generators. Through proper design and the integration of individual components, MNTs deliver controlled mechanical stimulation to targeted biomolecules at any desired space and time. We first discuss about MNT configuration with different force-stimulation modes. By modulating geometry of the magnetic field generator, MNTs exert pulling, dipole-dipole attraction, and rotational forces to the target specifically and quantitatively. We discuss the key physical parameters determining force magnitude, which include magnetic field strength, magnetic field gradient, magnetic moment of the magnetic particle, as well as distance between the field generator and the particle. MNTs also can be used over a wide range of biological time scales. By simply

  3. Optical measuring system with an interrogator and a polymer-based single-mode fibre optic sensor system

    DEFF Research Database (Denmark)

    2017-01-01

    The present invention relates to an optical measuring system comprising a polymer-based single-mode fibre-optic sensor system (102), an optical interrogator (101), and an optical arrangement (103) interconnecting the optical interrogator (101) and the polymer-based single-mode fibre-optic sensor...... system (102). The invention further relates to an optical interrogator adapted to be connected to a polymer-based single-mode fibre-optic sensor system via an optical arrangement. The interrogator comprises a broadband light source arrangement (104) and a spectrum analysing arrangement which receives...

  4. High-Speed Interrogation for Large-Scale Fiber Bragg Grating Sensing.

    Science.gov (United States)

    Hu, Chenyuan; Bai, Wei

    2018-02-24

    A high-speed interrogation scheme for large-scale fiber Bragg grating (FBG) sensing arrays is presented. This technique employs parallel computing and pipeline control to modulate incident light and demodulate the reflected sensing signal. One Electro-optic modulator (EOM) and one semiconductor optical amplifier (SOA) were used to generate a phase delay to filter reflected spectrum form multiple candidate FBGs with the same optical path difference (OPD). Experimental results showed that the fastest interrogation delay time for the proposed method was only about 27.2 us for a single FBG interrogation, and the system scanning period was only limited by the optical transmission delay in the sensing fiber owing to the multiple simultaneous central wavelength calculations. Furthermore, the proposed FPGA-based technique had a verified FBG wavelength demodulation stability of ±1 pm without average processing.

  5. Wavelength interrogation of fiber Bragg grating sensors using tapered hollow Bragg waveguides.

    Science.gov (United States)

    Potts, C; Allen, T W; Azar, A; Melnyk, A; Dennison, C R; DeCorby, R G

    2014-10-15

    We describe an integrated system for wavelength interrogation, which uses tapered hollow Bragg waveguides coupled to an image sensor. Spectral shifts are extracted from the wavelength dependence of the light radiated at mode cutoff. Wavelength shifts as small as ~10  pm were resolved by employing a simple peak detection algorithm. Si/SiO₂-based cladding mirrors enable a potential operational range of several hundred nanometers in the 1550 nm wavelength region for a taper length of ~1  mm. Interrogation of a strain-tuned grating was accomplished using a broadband amplified spontaneous emission (ASE) source, and potential for single-chip interrogation of multiplexed sensor arrays is demonstrated.

  6. Characterization of a FBG sensor interrogation system based on a mode-locked laser scheme.

    Science.gov (United States)

    Madrigal, Javier; Fraile-Peláez, Francisco Javier; Zheng, Di; Barrera, David; Sales, Salvador

    2017-10-02

    This paper is focused on the characterization of a fiber Bragg grating (FBG) sensor interrogation system based on a fiber ring laser with a semiconductor optical amplifier as the gain medium, and an in-loop electro-optical modulator. This system operates as a switchable active (pulsed) mode-locked laser. The operation principle of the system is explained theoretically and validated experimentally. The ability of the system to interrogate an array of different FBGs in wavelength and spatial domain is demonstrated. Simultaneously, the influence of several important parameters on the performance of the interrogation technique has been investigated. Specifically, the effects of the bandwidth and the reflectivity of the FBGs, the SOA gain, and the depth of the intensity modulation have been addressed.

  7. Interrogation in Teacher-Student Interaction in Bahasa Indonesia Learning at Elementary School

    Directory of Open Access Journals (Sweden)

    Akmal Hamsa

    2014-08-01

    Full Text Available Interrogation in Teacher-Student Interaction in Bahasa Indonesia Learning at Elementary School. This study aimed to describe the form, function, and questioning strategies teachers in teacher-student interrogation in Bahasa Indonesia learning in elementary school. Data sourced from four teacher of elementary school, SDN Tamangapa and SD Inpres Tamangapa. Data were obtained by (1 recording, (2 documentation, (3 field notes, (4 interview. The results showed that: (1 the form of questioning the teacher in the teacher-student interaction in Bahasa Indonesia learning in primary schools generally examined the low-level thinking skills, (2 functions of teacher questions are generally intended to check student understanding, and (3 teachers utilize a variety of strategies in addressing student answers correctly and the apparent hesitation. Some disadvantages are indicated teachers in providing interrogation.

  8. Prosodic differences between declaratives and interrogatives in infant-directed speech.

    Science.gov (United States)

    Geffen, Susan; Mintz, Toben H

    2017-07-01

    In many languages, declaratives and interrogatives differ in word order properties, and in syntactic organization more broadly. Thus, in order to learn the distinct syntactic properties of the two sentence types, learners must first be able to distinguish them using non-syntactic information. Prosodic information is often assumed to be a useful basis for this type of discrimination, although no systematic studies of the prosodic cues available to infants have been reported. Analysis of maternal speech in three Standard American English-speaking mother-infant dyads found that polar interrogatives differed from declaratives on the patterning of pitch and duration on the final two syllables, but wh-questions did not. Thus, while prosody is unlikely to aid discrimination of declaratives from wh-questions, infant-directed speech provides prosodic information that infants could use to distinguish declaratives and polar interrogatives. We discuss how learners could leverage this information to identify all question forms, in the context of syntax acquisition.

  9. The interrogation decision-making model: A general theoretical framework for confessions.

    Science.gov (United States)

    Yang, Yueran; Guyll, Max; Madon, Stephanie

    2017-02-01

    This article presents a new model of confessions referred to as the interrogation decision-making model . This model provides a theoretical umbrella with which to understand and analyze suspects' decisions to deny or confess guilt in the context of a custodial interrogation. The model draws upon expected utility theory to propose a mathematical account of the psychological mechanisms that not only underlie suspects' decisions to deny or confess guilt at any specific point during an interrogation, but also how confession decisions can change over time. Findings from the extant literature pertaining to confessions are considered to demonstrate how the model offers a comprehensive and integrative framework for organizing a range of effects within a limited set of model parameters. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  10. Neutron interrogation of actinides with a 17 MeV electron accelerator and first results from photon and neutron interrogation non-simultaneous measurements combination

    Energy Technology Data Exchange (ETDEWEB)

    Sari, A., E-mail: adrien.sari@cea.fr [CEA, LIST, Laboratoire Capteurs et Architectures Electroniques, 91191 Gif-sur-Yvette Cedex (France); Carrel, F.; Lainé, F. [CEA, LIST, Laboratoire Capteurs et Architectures Electroniques, 91191 Gif-sur-Yvette Cedex (France); Lyoussi, A. [CEA, DEN, 13108 Saint-Paul-Lez-Durance Cedex (France)

    2013-10-01

    In this article, we demonstrate the feasibility of neutron interrogation using the conversion target of a 17 MeV linear electron accelerator as a neutron generator. Signals from prompt neutrons, delayed neutrons, and delayed gamma-rays, emitted by both uranium and plutonium samples were analyzed. First results from photon and neutron interrogation non-simultaneous measurements combination are also reported in this paper. Feasibility of this technique is shown in the frame of the measurement of uranium enrichment. The latter was carried out by combining detection of prompt neutrons from thermal fission and delayed neutrons from photofission, and by combining delayed gamma-rays from thermal fission and delayed gamma-rays from photofission.

  11. Protease-activated receptor (PAR)-2 is required for PAR-1 signalling in pulmonary fibrosis

    NARCIS (Netherlands)

    Lin, Cong; von der Thüsen, Jan; Daalhuisen, Joost; ten Brink, Marieke; Crestani, Bruno; van der Poll, Tom; Borensztajn, Keren; Spek, C. Arnold

    2015-01-01

    Idiopathic pulmonary fibrosis is the most devastating diffuse fibrosing lung disease of unknown aetiology. Compelling evidence suggests that both protease-activated receptor (PAR)-1 and PAR-2 participate in the development of pulmonary fibrosis. Previous studies have shown that bleomycin-induced

  12. INL Active Interrogation Testing In Support of the GNEP Safeguards Campaign

    International Nuclear Information System (INIS)

    David L. Chichester

    2008-01-01

    Active interrogation, a measurement technique which uses a radiation source to probe materials and generate unique signatures useful for characterizing those materials, is a powerful tool for assaying special nuclear material. Work at Idaho National Laboratory (INL) in the area of active interrogation, using neutron and photon sources, has been under way for many years to develop methods for detecting and quantifying nuclear material for national and homeland security research areas. This research knowledge base is now being extended to address nuclear safeguards and process monitoring issues related to the Global Nuclear Energy Partnership (GNEP). As a first step in this area preliminary scoping studies have been performed to investigate the usefulness of using active neutron interrogation, with a low-power electronic neutron generator, to assay Department of Transportation 6M shipping drums containing uranium oxide fuel rodlets from INL's zero power physics reactor. Using the paired-counting technique during the die-away time period of interrogation, a lower detection limit of approximately 4.2 grams of enriched uranium (40% 235U) was calculated for a 40 minute measurement using a field portable 2.5 MeV neutron source and an array of 16 moderated helium-3 neutron tubes. Future work in this area, including the use of a more powerful neutron source and a better tailored detector array, would likely improve this limit to a much lower level. Further development work at INL will explore the applicability of active interrogation in association with the nuclear safeguards and process monitoring needs of the advanced GNEP facilities under consideration. This work, which will include both analyses and field demonstrations, will be performed in collaboration with colleagues at INL and elsewhere that have expertise in nuclear fuel reprocessing as well as active interrogation and its use for nuclear material analyses

  13. Promotion COPERNIC Energy and Society the interrogations on the world demand evolution

    International Nuclear Information System (INIS)

    2001-12-01

    In the framework of a prospective reflexion emergence on the energy demand, this document presents an analysis of the prospective approach and of recent studies: challenges, interests, limits, validity of the models and hypothesis and results relevance. With this analysis, the authors aim to identify the main interrogations bond to the world energy demand evolution. They then analyse these interrogations in the framework of a sectoral approach (agriculture, industry, transports, residential) in order to detail the demand and to forecast the evolution. Facing the consumption attitudes, they also suggest some new action avenues to favor a sustainable growth. (A.L.B.)

  14. Perioperative Interrogation of St. Jude Cardiovascular Implantable Electronic Devices: A Guide for Anesthesiologists.

    Science.gov (United States)

    Cronin, Brett; Essandoh, Michael K

    2018-04-01

    Feelings of trepidation or uncertainty regarding cardiovascular implantable electronic devices (CIEDs) in the perioperative period can often be mitigated by a thorough knowledge of societal recommendations, recommended management options, and familiarity with CIEDs. Given that effective interpretation of an interrogation report is vital to determining perioperative management options and applying societal recommendations, the creation and interpretation of St. Jude CIED interrogation reports are discussed. In an effort to increase the familiarity with St. Jude transvenous CIEDs amongst anesthesiologists, basic programming of a St. Jude pacemaker and implantable cardioverter defibrillator (ICD) also are described. Published by Elsevier Inc.

  15. Hidden explosives detector employing pulsed neutron and x-ray interrogation

    International Nuclear Information System (INIS)

    Schultz, F.J.; Caldwell, J.T.

    1993-01-01

    Methods and systems for the detection of small amounts of modern, highly-explosive nitrogen-based explosives, such as plastic explosives, hidden in airline baggage. Several techniques are employed either individually or combined in a hybrid system. One technique employed in combination is X-ray imaging. Another technique is interrogation with a pulsed neutron source in a two-phase mode of operation to image both nitrogen and oxygen densities. Another technique employed in combination is neutron interrogation to form a hydrogen density image or three-dimensional map. In addition, deliberately-placed neutron-absorbing materials can be detected

  16. Accelerator requirements for fast-neutron interrogation of luggage and cargo

    International Nuclear Information System (INIS)

    Micklich, B.J.; Fink, C.L.; Yule, T.J.

    1995-01-01

    Several different fast-neutron based techniques are being studied for the detection of contraband substances in luggage and cargo containers. The present work discusses the accelerator requirements for fast-neutron transmission spectroscopy (FNTS), pulsed fast-neutron analysis (PFNA), and 14-MeV neutron interrogation. These requirements are based on the results of Monte-Carlo simulations of neutron or gamma detection rates. Accelerator requirements are driven by count-rate considerations, spatial resolution and acceptable uncertainties in elemental compositions. The authors have limited their analyses to luggage inspection with FNTS and to cargo inspection with PFNA or 14-MeV neutron interrogation

  17. Compact, low-cost, and high-resolution interrogation unit for optical sensors

    International Nuclear Information System (INIS)

    Kiesel, Peter; Schmidt, Oliver; Mohta, Setu; Johnson, Noble; Malzer, Stefan

    2006-01-01

    Compact wavelength detectors that resolve wavelength changes in the subpicometer range over a broad spectral range are presented. A photodiode array or position sensor device is coated with a linear variable filter that converts the wavelength of the incident light into a spatial intensity distribution. The centroid of the spatial distribution is determined by a differential readout of the two elements of the photodiode array or the position sensor device. The device can interrogate any optical sensor that produces a wavelength shift in response to a stimulus. The potential of this device was tested by interrogating fiber-Bragg-grating sensors

  18. Interrogation of weak Bragg grating sensors based on dual-wavelength differential detection.

    Science.gov (United States)

    Cheng, Rui; Xia, Li

    2016-11-15

    It is shown that for weak Bragg gratings the logarithmic ratio of reflected intensities at any two wavelengths within the spectrum follows a linear relationship with the Bragg wavelength shift, with a slope proportional to their wavelength spacing. This finding is exploited to develop a flexible, efficient, and cheap interrogation solution of weak fiber Bragg grating (FBGs), especially ultra-short FBGs, in distributed sensing based on dual-wavelength differential detection. The concept is experimentally studied in both single and distributed sensing systems with ultra-short FBG sensors. The work may form the basis of new and promising FBG interrogation techniques based on detecting discrete rather than continuous spectra.

  19. Hidden explosives detector employing pulsed neutron and x-ray interrogation

    Science.gov (United States)

    Schultz, Frederick J.; Caldwell, John T.

    1993-01-01

    Methods and systems for the detection of small amounts of modern, highly-explosive nitrogen-based explosives, such as plastic explosives, hidden in airline baggage. Several techniques are employed either individually or combined in a hybrid system. One technique employed in combination is X-ray imaging. Another technique is interrogation with a pulsed neutron source in a two-phase mode of operation to image both nitrogen and oxygen densities. Another technique employed in combination is neutron interrogation to form a hydrogen density image or three-dimensional map. In addition, deliberately-placed neutron-absorbing materials can be detected.

  20. Spectral Doppler interrogation of the patent foramen ovale-a window to left heart hemodynamics.

    Science.gov (United States)

    Fadel, Bahaa M; Husain, Aysha; Bakarman, Hatem; Dahdouh, Ziad; Salvo, Giovanni Di; Mohty, Dania

    2015-02-01

    Spectral Doppler interrogation of flow across a patent foramen ovale (PFO) allows recording of the instantaneous pressure gradient between left and right atrium (RA). The assessment of RA pressure using the size and collapsibility of the inferior vena cava would thus allow estimation of left atrial (LA) pressure. In this article, we illustrate the value of spectral Doppler interrogation of flow across the PFO by transthoracic echocardiography as a novel and simple tool for the assessment of LA pressure and left cardiac hemodynamics in addition to the conventional noninvasive parameters. © 2014, Wiley Periodicals, Inc.

  1. A l-nCi/g sensitivity transuranic waste assay system using pulsed neutron interrogation

    International Nuclear Information System (INIS)

    Kunz, W.E.; Atencio, J.D.; Caldwell, J.T.

    1980-01-01

    We have developed a pulsed thermal neutron interrogation system and have demonstrated a sub-1-nCi/g assay sensitivity for high density TRU wastes contained in 200-liter barrels. We detect prompt fission neutrons, resulting in greatly enhanced sensitivity compared to techniques in which delayed fission neutrons are detected. We observe a linear assay response over at least three orders of magnitude in 235 U (or 239 Pu) mass. We also have measured a flat (to +-10%) interrogation flux profile throughout the volume of a 200-liter barrel filled with 200 kg of sand and vermiculite, which indicates flatness of response to fissile material at different locations within the barrel

  2. High-Efficiency Quantum Interrogation Measurements via the Quantum Zeno Effect

    International Nuclear Information System (INIS)

    Kwiat, P. G.; White, A. G.; Mitchell, J. R.; Nairz, O.; Weihs, G.; Weinfurter, H.; Zeilinger, A.

    1999-01-01

    The phenomenon of quantum interrogation allows one to optically detect the presence of an absorbing object, without the measuring light interacting with it. In an application of the quantum Zeno effect, the object inhibits the otherwise coherent evolution of the light, such that the probability that an interrogating photon is absorbed can in principle be arbitrarily small. We have implemented this technique, achieving efficiencies of up to 73% , and consequently exceeding the 50% theoretical maximum of the original ''interaction-free'' measurement proposal. We have also predicted and experimentally verified a previously unsuspected dependence on loss. (c) 1999 The American Physical Society

  3. The relationship between criminal conviction and interrogative suggestibility among delinquent boys.

    Science.gov (United States)

    Gudjonsson, G H; Singh, K K

    1984-03-01

    This study investigates the relationship between interrogative suggestibility, as measured by the Gudjonsson Suggestibility Scale (GSS), and number of previous convictions among 35 delinquent boys. The GSS measures two independent aspects of suggestibility. First, the extent to which subjects give in to suggestive questions. Second, the extent to which subjects give in to interpersonal pressure given in the form of critical feedback about test performance. The number of convictions were found to correlate negatively with the latter aspect of interrogative suggestibility, but not significantly with the former.

  4. Long fiber Bragg grating sensor interrogation using discrete-time microwave photonic filtering techniques.

    Science.gov (United States)

    Ricchiuti, Amelia Lavinia; Barrera, David; Sales, Salvador; Thevenaz, Luc; Capmany, José

    2013-11-18

    A novel technique for interrogating photonic sensors based on long fiber Bragg gratings (FBGs) is presented and experimentally demonstrated, dedicated to detect the presence and the precise location of several spot events. The principle of operation is based on a technique used to analyze microwave photonics (MWP) filters. The long FBGs are used as quasi-distributed sensors. Several hot-spots can be detected along the FBG with a spatial accuracy under 0.5 mm using a modulator and a photo-detector (PD) with a modest bandwidth of less than 1 GHz. The proposed interrogation system is intrinsically robust against environmental changes.

  5. On the actual bandwidth of some dynamic fiber optic strain/temperature interrogators

    Science.gov (United States)

    Preizler, Rotem R.; Davidi, R.; Motil, Avi; Botsev, Yakov; Hahami, Meir; Tur, Moshe

    2017-04-01

    The measurement accuracy of dynamic fiber-optic sensing interrogators, which use frequency scanning to determine the value of the measured, err as either the event bandwidth approaches half the instrument sampling frequency or when the event dynamic range comes close to the instrument designed value. One main source of error is the common practice of assigning sampling at a non-uniform grid to a uniform one. Harmonics higher than -20 dB are observed for signal frequencies exceeding 25% of the sampling rate and/or for signal amplitudes higher than 15% of the instrument dynamic range. These findings have applications to fiber-Bragg-grating and Brillouin interrogators.

  6. Determination of mineral radioactive strontium-{sup 90} in urines; Recherche du strontium mineral radioactif {sup 90}Sr dans les urines

    Energy Technology Data Exchange (ETDEWEB)

    Jeanmaire, L; Jammet, H; Bertrand, S [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    An analytical procedure for radioactive strontium in urine is described. As a first step, a precipitation of calcium oxalate performed on the urine, allows to detect the presence of various fission products and particularly of strontium which is carried by the precipitate. Strontium can then be selectively separated on ion exchange resins. By studying the growth curve of {beta} activity, it is possible to determine the activities which may be attributed to {sup 89}Sr and {sup 90}Sr respectively. (author) [French] Cet article decrit une technique de dosage du strontium radioactif dans les urines. Dans un premier stade, une precipitation d'oxalate de calcium effectuee sur l'urine permet de deceler la presence de differents produits de fission et en particulier du strontium qui est entraine sur ce precipite. Il est possible ensuite de separer selectivement le strontium au moyen de resines echangeuses d'ions. L'examen de le courbe de croissance de l'activite {beta} permet de determiner les activites dues respectivement a {sup 89}Sr et {sup 90}Sr. (auteur)

  7. Use of ion exchange and early treatment of radioactive contamination in the digestive tract; Utilisation des echangeurs d'ions et traitement precoce de la contamination radioactive par voie digestive

    Energy Technology Data Exchange (ETDEWEB)

    Michon, G; Guilloux, M J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    The efficiency of cation exchange resins for the treatment of digestive contamination with strontium has been studied on rats. The results obtained show that the most efficient resins are those of sulfonic type when administered in the ammonium form. The treatment is still efficient when applied 45 minutes after the ingestion of strontium. In the most favourable cases, the radioactivity of the skeleton was lower by a factor 6 in the treated animals than in controls. This easily applicable, rather safe and non specific treatment deserves to be retained for use. (author) [French] Une etude de l'efficacite des resines echangeuses de cations dans le traitement d'une contamination digestive par le strontium a ete entreprise chez le rat. Les resultats montrent que parmi les resines, les plus efficaces sont celles de type sulfonique, administrees sous forme ammonium. Le traitement est encore efficace 45 minutes apres l'ingestion du strontium. Dans les meilleurs cas, le squelette des rats traites etait six fois moins radioactif que celui des temoins. Ce traitement d'emploi facile, peu dangereux, non specifique, merite d'etre retenu. (auteur)

  8. Study of the Fixation and Migration of Radioactive Cations in a Natural Ion Exchanger; Etude de la Fixation et de la Migration de Cations Radioactifs dans un Echangeur d'Ions Naturel; 0418 0417 0423 0427 0415 0414 ; Estudio de la Fijacion y de la Migracion de Cationes Radiactivos en un Cambiador Natural de Iones

    Energy Technology Data Exchange (ETDEWEB)

    Baetsle, L. [Centre d' Etudes de l' Energie Nucleaire, Mol (Belgium)

    1960-07-01

    With a view to utilizing lignite as a natural ion exchanger in the treatment of radioactive waste, a study was made of its physical and physico-chemical properties with reference to ion exchange. The distribution of Sr{sup 90} and Cs{sup 137} ions in the presence of Ca, Na and H was first examined and the equilibrium constants calculated. The kinetics and fixation of ions were then studied, and various parameters required for the calculation of ion-exchange beds were established. Study of the complex phenomenon of radioactive ion migration in the soil was started by the separate investigation of each component ionic equilibrium. (author) [French] Afin d'utiliser le lignite comme echangeur d'ions naturel dans le traitement d'eaux residuaires radioactives, uene etude a ete faite de ses proprietes physiques et physiochimiques, ayant trait a l'echange d'ions. En premier lieu on a etudie la distribution des ions {sup 90}Sr et {sup 137}Cs en presence de Ca, Na et H, et calcule les constantes d'equilibre. En second heu on a traite la cinetique de la fixation des ions, et etabli quelques parametres necessaires au calcul de hts d'echangeurs d'ions. L'etude du phenomene complexe de la migration des ions radioactifs dans le sol a ete abordee par l 'investigation separee de chacun des equilibres ioniques composants. (author) [Spanish] Con objeto de utilizar el lignito como cambiador natural de iones en el tratamiento de aguas residuales radiactivas, se han estudiado sus propiedades fisicas y fisicoquimicas en relacion con el intercambio de iones. En primer lugar, el autor ha estudiado la distribucion de los iones {sup 90}Sr y {sup 137}Cs en presencia de Ca, Na y H, y ha calculado las constantes de equilibrio. En segundo lugar ha estudiado la cinetica de la fijacion de iones y ha establecido algunos parametros necesarios para calcular los lechos de cambiadores de iones. El autor ha abordado el estudio del complejo fenomeno de la migracion de iones radiactivos en el suelo

  9. Management of Waste from the Use of Radioisotopes; Divers Aspects Resultant de l'Utilisation des Isotopes Radioactifs; 0423 0414 0410 041b 0415 041d 0418 0415 041e 0422 0425 041e 0414 ; Diversos Aspectos Relacionados con los Desechos Procedentes del Empleo de Radioisotopos

    Energy Technology Data Exchange (ETDEWEB)

    Rogers, Lester R. [Radiation Safety Branch, Division of Licensing and Regulation, United States Atomic Energy Commission (United States)

    1960-07-01

    The author examines the origin and nature of radioactive waste generated in the use of radioisotopes in industry, medicine, agriculture and research and studies the relationship between types, quantities and uses of radioisotopes and disposal of the radioactive waste generated in their use. He also discusses the methods used for the disposal of such waste under the licensing controls of the United States Atomic Energy Commission. These methods include: 1. The controlled discharge of low concentrations of effluents into streams and into the atmosphere; 2. Controlled release of small quantities of soluble or readily dispersible waste products into sanitary sewage systems; 3. Burial, under controlled conditions, of small quantities of waste in the soil ; 4. Return to AEC installations of radioactive waste for storage or land burial ; 5. Treatment by incineration; and 6. Disposal of packaged waste at sea. The paper reviews the criteria and regulatory requirements applicable to cach method of disposal to accomplish the objective of preventing the waste from entering the food chain of man in hazardous quantities, or of adversely affecting the use of the environment by man. It goes on to discuss the limitations on the types, quantities, and methods of disposal for which private concerns can be licensed due to long-term responsibility for maintenance of burial grounds or storage facilities. (author) [French] L'auteur se propose d'examiner l'origine et la nature des dechets radioactifs resultant de l'utflisation des radioisotopes dans l'industrie, la medecine, l'agriculture et dans les laboratoires de recherche, et d'etudier les rapports qui existent entre les types, les quantites et les utilisations des radioisotopes, d'une part, et les dechets de leur production, d'autre part. Il etudie aussi les methodes utilisees pour l'elimination de ces dechets conformement aux mesures de controle appliquees par la Commission de l'energie atomique des Etats-Unis. Les methodes

  10. Can You Believe It? 12-Month-Olds Use Word Order to Distinguish between Declaratives and Polar Interrogatives

    Science.gov (United States)

    Geffen, Susan; Mintz, Toben H.

    2015-01-01

    Word order is a core mechanism for conveying syntactic structure, yet interrogatives usually disrupt canonical word orders. For example, in English, polar interrogatives typically invert the subject and auxiliary verb and insert an utterance-initial "do" if no auxiliary is present. These word order patterns result from differences in the…

  11. Interferometric interrogation of π-phase shifted fiber Bragg grating sensors

    Science.gov (United States)

    Srivastava, Deepa; Tiwari, Umesh; Das, Bhargab

    2018-03-01

    Interferometric interrogation technique realized for conventional fiber Bragg grating (FBG) sensors is historically known to offer the highest sensitivity measurements, however, it has not been yet explored for π-phase-shifted FBG (πFBG) sensors. This, we believe, is due to the complex nature of the reflection/transmission spectrum of a πFBG, which cannot be directly used for interferometric interrogation purpose. Therefore, we propose here an innovative as well as simple concept towards this direction, wherein, the transmission spectrum of a πFBG sensor is optically filtered using a specially designed fiber grating. The resulting filtered spectrum retains the entire characteristics of a πFBG sensor and hence the filtered spectrum can be interrogated with interferometric principles. Furthermore, due to the extremely narrow transmission notch of a πFBG sensor, a fiber interferometer can be realized with significantly longer path difference. This leads to substantially enhanced detection limit as compared to sensors based on a regular FBG of similar length. Theoretical analysis demonstrates that high resolution weak dynamic strain measurement down to 4 pε /√{ Hz } is easily achievable. Preliminary experimental results are also presented as proof-of-concept of the proposed interrogation principle.

  12. Investigation of Active Interrogation Techniques to Detect Special Nuclear Material in Maritime Environments

    International Nuclear Information System (INIS)

    Miller, Thomas Martin; Patton, Bruce W.

    2010-01-01

    The detection and interdiction of special nuclear material (SNM) is still a high-priority focus area for many organizations around the world. One method that is commonly considered a leading candidate in the detection of SNM is active interrogation (AI). AI is different from its close relative, passive interrogation, in that an active source is used to enhance or create a detectable signal (usually fission) from SNM, particularly in shielded scenarios or scenarios where the SNM has a low activity. The use of AI thus makes the detection of SNM easier or, in some scenarios, even enables previously impossible detection. In this work the signal from prompt neutrons and photons as well as delayed neutrons and photons will be combined, as is typically done in AI. In previous work AI has been evaluated experimentally and computationally. However, for the purposes of this work, past scenarios are considered lightly shielded and tightly coupled spatially. At most, the previous work interrogated the contents of one standard cargo container (2.44 x 2.60 x 6.10 m) and the source and detector were both within a few meters of the object being interrogated. A few examples of this type of previous work can be found in references 1 and 2. Obviously, more heavily shielded AI scenarios will require larger source intensities, larger detector surface areas (larger detectors or more detectors), greater detector efficiencies, longer count times, or some combination of these.

  13. A high-temperature fiber sensor using a low cost interrogation scheme.

    Science.gov (United States)

    Barrera, David; Sales, Salvador

    2013-09-04

    Regenerated Fibre Bragg Gratings have the potential for high-temperature monitoring. In this paper, the inscription of Fibre Bragg Gratings (FBGs) and the later regeneration process to obtain Regenerated Fiber Bragg Gratings (RFBGs) in high-birefringence optical fiber is reported. The obtained RFBGs show two Bragg resonances corresponding to the slow and fast axis that are characterized in temperature terms. As the temperature increases the separation between the two Bragg resonances is reduced, which can be used for low cost interrogation. The proposed interrogation setup is based in the use of optical filters in order to convert the wavelength shift of each of the Bragg resonances into optical power changes. The design of the optical filters is also studied in this article. In first place, the ideal filter is calculated using a recursive method and defining the boundary conditions. This ideal filter linearizes the output of the interrogation setup but is limited by the large wavelength shift of the RFBG with temperature and the maximum attenuation. The response of modal interferometers as optical filters is also analyzed. They can be easily tuned shifting the optical spectrum. The output of the proposed interrogation scheme is simulated in these conditions improving the sensitivity.

  14. Resolution-improved in situ DNA hybridization detection based on microwave photonic interrogation.

    Science.gov (United States)

    Cao, Yuan; Guo, Tuan; Wang, Xudong; Sun, Dandan; Ran, Yang; Feng, Xinhuan; Guan, Bai-ou

    2015-10-19

    In situ bio-sensing system based on microwave photonics filter (MPF) interrogation method with improved resolution is proposed and experimentally demonstrated. A microfiber Bragg grating (mFBG) is used as sensing probe for DNA hybridization detection. Different from the traditional wavelength monitoring technique, we use the frequency interrogation scheme for resolution-improved bio-sensing detection. Experimental results show that the frequency shift of MPF notch presents a linear response to the surrounding refractive index (SRI) change over the range of 1.33 to 1.38, with a SRI resolution up to 2.6 × 10(-5) RIU, which has been increased for almost two orders of magnitude compared with the traditional fundamental mode monitoring technique (~3.6 × 10(-3) RIU). Due to the high Q value (about 27), the whole process of DNA hybridization can be in situ monitored. The proposed MPF-based bio-sensing system provides a new interrogation method over the frequency domain with improved sensing resolution and rapid interrogation rate for biochemical and environmental measurement.

  15. High performance multi-spectral interrogation for surface plasmon resonance imaging sensors.

    Science.gov (United States)

    Sereda, A; Moreau, J; Canva, M; Maillart, E

    2014-04-15

    Surface plasmon resonance (SPR) sensing has proven to be a valuable tool in the field of surface interactions characterization, especially for biomedical applications where label-free techniques are of particular interest. In order to approach the theoretical resolution limit, most SPR-based systems have turned to either angular or spectral interrogation modes, which both offer very accurate real-time measurements, but at the expense of the 2-dimensional imaging capability, therefore decreasing the data throughput. In this article, we show numerically and experimentally how to combine the multi-spectral interrogation technique with 2D-imaging, while finding an optimum in terms of resolution, accuracy, acquisition speed and reduction in data dispersion with respect to the classical reflectivity interrogation mode. This multi-spectral interrogation methodology is based on a robust five parameter fitting of the spectral reflectivity curve which enables monitoring of the reflectivity spectral shift with a resolution of the order of ten picometers, and using only five wavelength measurements per point. In fine, such multi-spectral based plasmonic imaging system allows biomolecular interaction monitoring in a linear regime independently of variations of buffer optical index, which is illustrated on a DNA-DNA model case. © 2013 Elsevier B.V. All rights reserved.

  16. Radio-frequency unbalanced M-Z interferometer for wavelength interrogation of fiber Bragg grating sensors.

    Science.gov (United States)

    Zhou, Jiaao; Xia, Li; Cheng, Rui; Wen, Yongqiang; Rohollahnejad, Jalal

    2016-01-15

    The optical unbalanced Mach-Zehnder interferometer (UMZI) has attracted significant interests for interrogation of FBG sensors owing to its excellent advantages in sensitivity, resolution, and demodulation speed. But this method is still limited to dynamic measurements due to its poor stability and reliability when used for quasi-static detections. Here, we propose for the first time, to the best of our knowledge, a radio-frequency unbalanced M-Z interferometer (RF-UMZI) for interrogation of FBG sensors, which, owing to its operation in an incoherent rather than a coherent regime, provides an ideal solution for the existing stability problem of the conventional UMZI, with remarkable features of adjustable resolution and potentially extremely high sensitivity. A dispersion compensation fiber (DCF) and single-mode fiber (SMF) with a small length difference are served as the two unbalanced arms of the RF interferometer. The induced differential chromatic dispersion transfers the wavelength shift of the FBG to the change of the RF phase difference between the two interferometric carriers, which ultimately leads to the variation of the RF signal intensity. An interrogation of a strain-turned FBG was accomplished and a maximum sensitivity of 0.00835  a.u./με was obtained, which can easily be further improved by more than two orders of magnitude through various fiber dispersion components. Finally, the stability of the interrogation was tested.

  17. An Evaluation of "Miranda" Rights and Interrogation in Autism Spectrum Disorders

    Science.gov (United States)

    Salseda, Lindsay M.; Dixon, Dennis R.; Fass, Tracy; Miora, Deborah; Leark, Robert A.

    2011-01-01

    The primary deficits present in autism spectrum disorders (ASD) may lead to increased susceptibility to involvement in the criminal justice system. The same deficits may also cause individuals with ASD to be more vulnerable to interrogation techniques and other aspects of the legal system. Due to the increased level of vulnerability as well as…

  18. Overcoming Innocents' Naiveté: Pre-interrogation Decision-making Among Innocent Suspects.

    Science.gov (United States)

    Scherr, Kyle C; Alberts, Kimberly M; Franks, Andrew S; Hawkins, Ian

    2016-07-01

    Suspects, especially innocent ones, are highly susceptible to waiving their interrogation rights. This research tested the ability of two strategies to overcome innocent suspects' willingness to waive their rights. One strategy was based on the social influence of scarcity (i.e., not constraining the pre-interrogation time limit). The other strategy focused on disrupting individuals' cognitive fluency during the decision-making process (i.e., violating their induced expectation of offering a waiver). Disrupting innocent individuals' cognitive fluency increased their willingness to invoke their rights and, notably, was not qualified by interactions with any other factors. However, scarcity did not influence individuals' pre-interrogation decision-making. Results also further established the association between innocent individuals' naïve mindset and their willingness to waive their rights - specifically, innocents' willingness to waive their rights increased with the strength of their just world beliefs. The theoretical and applied implications of these findings are discussed. The importance and benefit of reforming pre-interrogation protocols using fair and feasible strategies that would disrupt suspects' cognitive fluency are emphasized. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  19. The Lawyer in the Dutch Interrogation Room: Influence on Police and Suspect

    NARCIS (Netherlands)

    W-J. Verhoeven (Willem-Jan); L. Stevens (Lonneke)

    2012-01-01

    textabstractIn many European countries, providing a suspect in custody with legal aid before the first police interrogation is a heavily debated issue. In this paper, we report on an exploratory study on the use of coercion by the police and the use of the right to silence by suspects in 70 Dutch

  20. Nanoscale Plasmonic V-Groove Waveguides for the Interrogation of Single Fluorescent Bacterial Cells

    DEFF Research Database (Denmark)

    Lotan, Oren; Bar-David, Jonathan; Smith, Cameron

    2017-01-01

    We experimentally demonstrate the interrogation of an individual Escherichia coli cell using a nanoscale plasmonic V-groove waveguide. Several different configurations were studied. The first involved the excitation of the cell in a liquid environment because it flows on top of the waveguide...

  1. Reading Resistance: The Record of Tsunesaburo Makiguchi's Interrogation by Wartime Japan's "Thought Police"

    Science.gov (United States)

    Ito, Takao

    2009-01-01

    This article examines the record of Tsunesaburo Makiguchi's interrogation as a thought criminal following his arrest in July, 1943. By comparing and contrasting his responses and statements against the official government positions, I hope to clarify the nature of his critique of the wartime fascist regime. Makiguchi himself was an educator, and…

  2. The relationship of intelligence and memory to interrogative suggestibility: the importance of range effects.

    Science.gov (United States)

    Gudjonsson, G H

    1988-05-01

    This paper looks at the relationship between intelligence, memory and interrogative suggestibility, particularly with reference to range effects. The subjects were 60 normal subjects and 100 forensic patients who had completed the Gudjonsson Suggestibility Scale (GSS) and the Wechsler Adult Intelligence Scale. Clear range effects of IQ and memory were evident in their relationship with suggestibility.

  3. Interrogative Suggestibility among Adolescent Boys and Its Relationship with Intelligence, Memory, and Cognitive Set.

    Science.gov (United States)

    Singh, Krishna K.; Gudjonsson, Gisli H.

    1992-01-01

    Investigated hypotheses generated by Gudjonsson and Clark model of interrogative suggestibility. Adolescent boys (n=40) completed Gudjonsson Suggestibility Scale and measures of intellectual skills, memory, field-dependence, hostility, and attitudes toward persons in authority. Suggestibility correlated negatively with intelligence quotient and…

  4. The recognition of acted interpersonal stance in police interrogations and the influence of actor proficiency

    NARCIS (Netherlands)

    Bruijnes, Merijn; op den Akker, Hendrikus J.A.; Spitters, Sophie; Sanders, Merijn; Fu, Quihua

    2015-01-01

    This paper reports on judgement studies regarding the perception of interpersonal stances taken by humans playing the role of a suspect in a police interrogation setting. Our project aims at building believable embodied conversational characters to play the role of suspects in a serious game for

  5. French Interrogative Structures: A New Pedagogical Norm for the 21st-Century Classroom

    Science.gov (United States)

    Antes, Theresa A.

    2016-01-01

    This study investigated interrogative structures most frequently used by native speakers of French, in an attempt to reconcile differences between language forms taught in the French as a foreign language classroom and those that are encountered in authentic input. Radio, television, and magazine interviews provided multiple examples of…

  6. Asking for Action or Information? Crosslinguistic Comparison of Interrogative Functions in Early Child Cantonese and Mandarin

    Science.gov (United States)

    Li, Hui; Wong, Eileen Chin Mei; Tse, Shek Kam; Leung, Shing On; Ye, Qianling

    2015-01-01

    Request for information (RfI) is believed to be the universally dominant function of young children's questioning, whereas request for action (RfA) has been reported to be the leading interrogative form used in early child Cantonese. The possibility of crosslinguistic variability prompts further research and comparison with additional languages.…

  7. ParA and ParB coordinate chromosome segregation with cell elongation and division during Streptomyces sporulation

    Science.gov (United States)

    Donczew, Magdalena; Mackiewicz, Paweł; Wróbel, Agnieszka; Flärdh, Klas; Zakrzewska-Czerwińska, Jolanta

    2016-01-01

    In unicellular bacteria, the ParA and ParB proteins segregate chromosomes and coordinate this process with cell division and chromosome replication. During sporulation of mycelial Streptomyces, ParA and ParB uniformly distribute multiple chromosomes along the filamentous sporogenic hyphal compartment, which then differentiates into a chain of unigenomic spores. However, chromosome segregation must be coordinated with cell elongation and multiple divisions. Here, we addressed the question of whether ParA and ParB are involved in the synchronization of cell-cycle processes during sporulation in Streptomyces. To answer this question, we used time-lapse microscopy, which allows the monitoring of growth and division of single sporogenic hyphae. We showed that sporogenic hyphae stop extending at the time of ParA accumulation and Z-ring formation. We demonstrated that both ParA and ParB affect the rate of hyphal extension. Additionally, we showed that ParA promotes the formation of massive nucleoprotein complexes by ParB. We also showed that FtsZ ring assembly is affected by the ParB protein and/or unsegregated DNA. Our results indicate the existence of a checkpoint between the extension and septation of sporogenic hyphae that involves the ParA and ParB proteins. PMID:27248800

  8. Police training in interviewing and interrogation methods: A comparison of techniques used with adult and juvenile suspects.

    Science.gov (United States)

    Cleary, Hayley M D; Warner, Todd C

    2016-06-01

    Despite empirical progress in documenting and classifying various interrogation techniques, very little is known about how police are trained in interrogation methods, how frequently they use various techniques, and whether they employ techniques differentially with adult versus juvenile suspects. This study reports the nature and extent of formal (e.g., Reid Technique, PEACE, HUMINT) and informal interrogation training as well as self-reported technique usage in a diverse national sample (N = 340) of experienced American police officers. Officers were trained in a variety of different techniques ranging from comparatively benign pre-interrogation strategies (e.g., building rapport, observing body language or speech patterns) to more psychologically coercive techniques (e.g., blaming the victim, discouraging denials). Over half the sample reported being trained to use psychologically coercive techniques with both adults and juveniles. The majority (91%) receive informal, "on the job" interrogation training. Technique usage patterns indicate a spectrum of psychological intensity where information-gathering approaches were used most frequently and high-pressure tactics less frequently. Reid-trained officers (56%) were significantly more likely than officers without Reid training to use pre-interrogation and manipulation techniques. Across all analyses and techniques, usage patterns were identical for adult and juvenile suspects, suggesting that police interrogate youth in the same manner as adults. Overall, results suggest that training in specific interrogation methods is strongly associated with usage. Findings underscore the need for more law enforcement interrogation training in general, especially with juvenile suspects, and highlight the value of training as an avenue for reducing interrogation-induced miscarriages of justice. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  9. Contamination potentielle des aliments par des ...

    African Journals Online (AJOL)

    SARA Computers

    la notion de la pollution et de l'exposition aux PCBs, lorsque 77% n'ont pas conscience de cette situation de risque ... 2018). Quoique la contamination par les. PCBs soit de faible niveau, elle est ...... Université Paris-Est, Paris, France ; 183.

  10. Design challenges of a tunable laser interrogator for geo-stationary communication satellites

    Science.gov (United States)

    Ibrahim, Selwan K.; Honniball, Arthur; McCue, Raymond; Todd, Michael; O'Dowd, John A.; Sheils, David; Voudouris, Liberis; Farnan, Martin; Hurni, Andreas; Putzer, Philipp; Lemke, Norbert; Roner, Markus

    2017-09-01

    Recently optical sensing solutions based on fiber Bragg grating (FBG) technology have been proposed for temperature monitoring in telecommunication satellite platforms with an operational life time beyond 15 years in geo-stationary orbit. Developing radiation hardened optical interrogators designed to be used with FBG sensors inscribed in radiation tolerant fibers offer the capabilities of multiplexing multiple sensors on the same fiber and reducing the overall weight by removing the copper wiring harnesses associated with electrical sensors. Here we propose the use of a tunable laser based optical interrogator that uses a semiconductor MG-Y type laser that has no moving parts and sweeps across the C-band wavelength range providing optical power to FBG sensors and optical wavelength references such as athermal Etalons and Gas Cells to guarantee stable operation of the interrogator over its targeted life time in radiation exposed environments. The MG-Y laser was calibrated so it remains in a stable operation mode which ensures that no mode hops occur due to aging of the laser, and/or thermal or radiation effects. The key optical components including tunable laser, references and FBGs were tested for radiation tolerances by emulating the conditions on a geo-stationary satellite including a Total Ionizing Dose (TID) radiation level of up to 100 krad for interrogator components and 25 Mrad for FBGs. Different tunable laser control, and signal processing algorithms have been designed and developed to fit within specific available radiation hardened FPGAs to guarantee operation of a single interrogator module providing at least 1 sample per second measurement capability across engineering model system developed in the frame of an ESA-ARTES program and is planned to be deployed as a flight demonstrator on-board the German Heinrich Hertz geo-stationary satellite.

  11. Police reports of mock suspect interrogations: A test of accuracy and perception.

    Science.gov (United States)

    Kassin, Saul M; Kukucka, Jeff; Lawson, Victoria Z; DeCarlo, John

    2017-06-01

    A 2-phased experiment assessed the accuracy and completeness of police reports on mock interrogations and their effects on people's perceptions. In Phase 1, 16 experienced officers investigated a mock crime scene, interrogated 2 innocent suspects-1 described by the experimenter as more suspicious than the other-and filed an incident report. All 32 sessions were covertly recorded; the recordings were later used to assess the reports. In Phase 2, 96 lay participants were presented with a brief summary of the case and then either read 1 police report, read 1 verbatim interrogation transcript, or listened to an audiotape of a session. Results showed that (a) Police and suspects diverged in their perceptions of the interrogations; (b) Police committed frequent errors of omission in their reports, understating their use of confrontation, maximization, leniency, and false evidence; and (c) Phase 2 participants who read a police report, compared to those who read a verbatim transcript, perceived the process as less pressure-filled and were more likely to misjudge suspects as guilty. These findings are limited by the brevity and low-stakes nature of the task and by the fact that no significant effects were obtained for our suspicion manipulation, suggesting a need for more research. Limitations notwithstanding, this study adds to a growing empirical literature indicating the need for a requirement that all suspect interrogations be electronically recorded. To provide a more objective and accurate account of what transpired, this study also suggests the benefit of producing verbatim transcripts. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  12. CFD analysis of PAR performance as function of inlet design

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kweonha, E-mail: khpark@kmou.ac.kr [Division of Mechanical and Energy systems Engineering, Korea Maritime University, Dongsam-dong, Yeongdo-gu, Busan 606-791 (Korea, Republic of); Khor, Chong Lee, E-mail: itachi_829@hotmail.com [Department of Mechanical Engineering, Korea Maritime University (Korea, Republic of)

    2016-01-15

    Highlights: • The new concept of PAR (passive autocatalytic recombiner) was proposed and analyzed. • Guidance wall was added at the bottom of PAR to enhance the flow rate through the catalyst. • The new concept of PAR was proved to have a better hydrogen removal performance. - Abstract: Passive autocatalytic recombiner (PAR) is very useful hydrogen mitigation measurement. It is widely implemented in the current and advanced light water reactors (ALWRs). The design of the PARs should be optimized for the specific use under severe accident scenarios. Several techniques and innovations have been fused into the PAR, as an effort to increase its efficiency of hydrogen mitigation. This study proposes different concepts of PAR, which applied some changes to the honeycomb catalyst PAR made by the Korea Nuclear Technology (KNT) Inc. Two slices of plate are added to the bottom of PAR model, which intended to act as a reflection wall and promote the gas flow into PAR. Hydrogen volume fraction was given 4 vol. % which tested by KNT to investigate the performance of PAR in different direction gas flow conditions to see maximum hydrogen recombination rate. The new concept of PAR was proved to have a better hydrogen removal performance compared to the original honeycomb catalyst PAR.

  13. CFD analysis of PAR performance as function of inlet design

    International Nuclear Information System (INIS)

    Park, Kweonha; Khor, Chong Lee

    2016-01-01

    Highlights: • The new concept of PAR (passive autocatalytic recombiner) was proposed and analyzed. • Guidance wall was added at the bottom of PAR to enhance the flow rate through the catalyst. • The new concept of PAR was proved to have a better hydrogen removal performance. - Abstract: Passive autocatalytic recombiner (PAR) is very useful hydrogen mitigation measurement. It is widely implemented in the current and advanced light water reactors (ALWRs). The design of the PARs should be optimized for the specific use under severe accident scenarios. Several techniques and innovations have been fused into the PAR, as an effort to increase its efficiency of hydrogen mitigation. This study proposes different concepts of PAR, which applied some changes to the honeycomb catalyst PAR made by the Korea Nuclear Technology (KNT) Inc. Two slices of plate are added to the bottom of PAR model, which intended to act as a reflection wall and promote the gas flow into PAR. Hydrogen volume fraction was given 4 vol. % which tested by KNT to investigate the performance of PAR in different direction gas flow conditions to see maximum hydrogen recombination rate. The new concept of PAR was proved to have a better hydrogen removal performance compared to the original honeycomb catalyst PAR.

  14. SAFARI 2000 PAR Measurements, Kalahari Transect, Botswana, Wet Season 2000

    Data.gov (United States)

    National Aeronautics and Space Administration — Ceptometer data from a Decagon AccuPAR (Model PAR-80) were collected at four sites in Botswana during the SAFARI 2000 Kalahari Transect Wet Season Campaign (March,...

  15. Review of the incineration of 500 tonnes of radio-active residues; Bilan de l'incineration de 500 tonnes de residus radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    Rodier, J; Seyfried, P; Charbonneaux, M [Commissariat a l' Energie Atomique, Chusclan (France). Centre de Production de Plutonium de Marcoule

    1969-07-01

    During its first five years operation, the incinerator at the Marcoule Centre has burnt almost 500 tonnes of radio-active residues. Improvements in some of the details of the process have been made during this period; they concern the nature of the materials involved. The technical and radiological results for the installation are very favorable, and have made it possible to maintain a high charge factor.Although the overall economic results are not advantageous in the case of ungraded solid residues this method represents nevertheless the best available for eliminating oils, solvents, wood and dead animals. It can also be of use furthermore each time that a dilution in the atmosphere can advantageously be used as a method of disposing of certain radio elements such as tritium or carbon 14 in the form of gases or vapours. (author) [French] L'incinerateur du Centre de Marcoule a brule, durant les 5 premieres annees de fonctionnement, pres de 500 tonnes de residus radioactifs. Les ameliorations de detail realisees au cours de cette periode ont porte sur la nature des materiaux employes. Les bilans techniques et radiologiques de l'installation sont tres favorables et ont permis de maintenir un facteur de charge eleve. Si le bilan economique n'est pas favorable a l'incineration des residus solides 'tout venant' cette methode constitue cependant la solution ideale pour l'elimination des huiles, des solvants, du bois et des cadavres d'animaux. En outre, elle peut etre interessante chaque fois que la dilution dans l'atmosphere peut etre avantageusement mise a profit pour rejeter certains radioelements tels que le tritium ou le carbone 14 sous forme de gaz ou de vapeurs. (auteur)

  16. A national epidemiological study investigating risk factors for police interrogation and false confession among juveniles and young persons.

    Science.gov (United States)

    Gudjonsson, Gisli H; Sigurdsson, Jon Fridrik; Sigfusdottir, Inga Dora; Asgeirsdottir, Bryndis Bjork; González, Rafael A; Young, Susan

    2016-03-01

    The principal aims of this study are to identify risk factors associated with police arrest and false confessions and to investigate whether the severity of the ADHD condition/symptoms increases the risk. 22,226 young persons in Iceland anonymously completed self-report questionnaires screening for conduct disorder and ADHD. In addition, they stated whether they had a diagnosis of ADHD and had received ADHD medication, and their history of offending, police interrogation and false confession. Participants were stratified into two age groups, 14-16 and 17-24 years. The older group was significantly more likely to have been interrogated by the police but the younger group were much more vulnerable to false confession during interrogation. Males were more likely to be at risk for both than females. The severity of the ADHD condition increased the risk of both interrogation and false confession. Negative binomial regressions showed that age, gender, conduct disorder, offending, and ADHD symptoms were all significant predictors of both interrogations and number of false confessions. Conduct disorder was the single best predictor of police interrogation, but the findings were more mixed regarding false confessions. Young people presenting with a combination of severe ADHD and comorbid conduct disorder had the worst outcome for both interrogation and false confessions. The findings endorse the need for support of persons with ADHD to be put in place to ensure fair due process and to prevent miscarriages of justice.

  17. Investigation of active interrogation techniques to detect special nuclear material in maritime environments: Boarded search of a cargo container ship

    International Nuclear Information System (INIS)

    Grogan, Brandon R.; Henkel, James J.; Johnson, Jeffrey O.; Mihalczo, John T.; Miller, Thomas M.; Patton, Bruce W.

    2013-01-01

    The detonation of a terrorist nuclear weapon in the United States would result in the massive loss of life and grave economic damage. Even if a device was not detonated, its known or suspected presence aboard a cargo container ship in a U.S. port would have major economic and political consequences. One possible means to prevent this threat would be to board a ship at sea and search for the device before it reaches port. The scenario considered here involves a small Coast Guard team with strong intelligence boarding a container ship to search for a nuclear device. Using active interrogation, the team would nonintrusively search a block of shipping containers to locate the fissile material. Potential interrogation source and detector technologies for the team are discussed. The methodology of the scan is presented along with a technique for calculating the required interrogation source strength using computer simulations. MCNPX was used to construct a computer model of a container ship, and several search scenarios were simulated. The results of the simulations are presented in terms of the source strength required for each interrogation scenario. Validation measurements were performed in order to scale these simulation results to expected performance. Interrogations through the short (2.4 m) axis of a standardized shipping container appear to be feasible given the entire range of container loadings tested. Interrogations through several containers at once or a single container through its long (12.2 m) axis do not appear to be viable with a portable interrogation system

  18. Investigation of active interrogation techniques to detect special nuclear material in maritime environments: Boarded search of a cargo container ship

    Energy Technology Data Exchange (ETDEWEB)

    Grogan, Brandon R., E-mail: groganbr@ornl.gov; Henkel, James J.; Johnson, Jeffrey O.; Mihalczo, John T.; Miller, Thomas M.; Patton, Bruce W.

    2013-12-01

    The detonation of a terrorist nuclear weapon in the United States would result in the massive loss of life and grave economic damage. Even if a device was not detonated, its known or suspected presence aboard a cargo container ship in a U.S. port would have major economic and political consequences. One possible means to prevent this threat would be to board a ship at sea and search for the device before it reaches port. The scenario considered here involves a small Coast Guard team with strong intelligence boarding a container ship to search for a nuclear device. Using active interrogation, the team would nonintrusively search a block of shipping containers to locate the fissile material. Potential interrogation source and detector technologies for the team are discussed. The methodology of the scan is presented along with a technique for calculating the required interrogation source strength using computer simulations. MCNPX was used to construct a computer model of a container ship, and several search scenarios were simulated. The results of the simulations are presented in terms of the source strength required for each interrogation scenario. Validation measurements were performed in order to scale these simulation results to expected performance. Interrogations through the short (2.4 m) axis of a standardized shipping container appear to be feasible given the entire range of container loadings tested. Interrogations through several containers at once or a single container through its long (12.2 m) axis do not appear to be viable with a portable interrogation system.

  19. Plasma suPAR is lowered by smoking cessation

    DEFF Research Database (Denmark)

    Eugen-Olsen, Jesper; Ladelund, Steen; Sørensen, Lars Tue

    2016-01-01

    BACKGROUND: Soluble urokinase plasminogen activator receptor (suPAR) is a stable inflammatory biomarker. In patients, suPAR is a marker of disease presence, severity and prognosis. In the general population, suPAR is predictive of disease development, such as diabetes and cardiovascular disease a...

  20. Copenhagen uPAR prostate cancer (CuPCa) database

    DEFF Research Database (Denmark)

    Lippert, Solvej; Berg, Kasper D; Høyer-Hansen, Gunilla

    2016-01-01

    AIM: Urokinase plasminogen activator receptor (uPAR) plays a central role during cancer invasion by facilitating pericellular proteolysis. We initiated the prospective 'Copenhagen uPAR Prostate Cancer' study to investigate the significance of uPAR levels in prostate cancer (PCa) patients. METHODS...

  1. The inflammatory marker suPAR after cardiac arrest

    DEFF Research Database (Denmark)

    Rundgren, Malin; Lyngbaek, Stig; Fisker, Helle

    2015-01-01

    . This pilot study aimed at investigating suPAR levels in relation to outcome after CA and mild induced hypothermia. METHODS: suPAR levels were measured at 6, 36, and 72 hours in patients treated with hypothermia after CA. suPAR levels were analyzed in relation to survival after 6 months. Receiver operating...

  2. Use of electron beams for the production of radioactive nuclei through photo-fission; Utilisation de faisceaux d'electrons pour la production des noyaux radioactifs par photo-fission

    Energy Technology Data Exchange (ETDEWEB)

    M' garrech, Slah

    2004-09-01

    The IPN (institute of nuclear physics) of Orsay decided to build a linear accelerator in order to produce an electron beam of 50 MeV energy and of 10 {mu}A average intensity. It is the ALTO project (Linear Accelerator near the Tandem of Orsay). This project will be dedicated to the production of the radioactive ions using the photo-fission process. The central topic of this thesis is the study of the beam dynamics of the ALTO facility. The first part presents studies concerning the injector. The simulations made with the simulation code PARMELA allowed the optimization of the characteristics of pre-buncher (dephasing HF, accelerating field peak...) to obtain a good bunching factor at the entrance of the buncher and at the entrance of the accelerating section according to the distance separating the two systems. The second part of this thesis is related to measurements of transverse emittance of the beam at the buncher exit. The three gradients method has been selected and the optical system used is a solenoid. The results obtained are in good agreement with former measurements. Finally a calculation of the beam line was carried out to optimize the transport of the beam to the PARRNe target without degrading its characteristics. The calculation codes that have been used are BETA and TRACE-WIN. (author)

  3. Shape coexistence in krypton and selenium light isotopes studied through Coulomb excitation of radioactive ions beams; Etude de la coexistence de formes dans les isotopes legers du krypton et du selenium par excitation Coulombienne de faisceaux radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    Clement, E

    2006-06-15

    The light krypton isotopes show two minima in their potential energy corresponding to elongated (prolate) and compressed (oblate) quadrupole deformation. Both configuration are almost equally bound and occur within an energy range of less than 1 MeV. Such phenomenon is called shape coexistence. An inversion of the ground state deformation from prolate in Kr{sup 78} to oblate in Kr{sup 72} with strong mixing of the configurations in Kr{sup 74} and Kr{sup 76} was proposed based on the systematic of isotopic chain. Coulomb excitation experiments are sensitive to the quadrupole moment. Coulomb excitation experiments of radioactive Kr{sup 74} and Kr{sup 76} beam were performed at GANIL using the SPIRAL facility and the EXOGAM spectrometer. The analysis of these experiments resulted in a complete description of the transition strength and quadrupole moments of the low-lying states. They establish the prolate character of the ground state and an oblate excited state. A complementary lifetime measurement using a 'plunger' device was also performed. Transition strength in neighboring nuclei were measured using the technique of intermediate energy Coulomb excitation at GANIL. The results on the Se{sup 68} nucleus show a sharp change in structure with respects to heavier neighboring nuclei. (author)

  4. Problems raised by radioactive ion acceleration in the SPIRAL project. Accelerator tuning and stabilisation; Problemes poses par l`acceleration d`ions radioactifs dans le project SPIRAL. Reglage et stabilisation de l`accelerateur

    Energy Technology Data Exchange (ETDEWEB)

    Boy, L. [Paris-6 Univ., 75 (France)

    1997-12-31

    This study is related to the SPIRAL project. This facility uses a cyclotron to accelerate radioactive ion beams produced in a thick target by the Grant Accelerateur National d`Ions Lourds primary beam. The low intensity of radioactive beams and the mixing of several species imply special tuning methods and associated diagnostics. Also, a cyclotron and the beam line will be used to switch from this tuning beam to the radioactive one. We present a theoretical study and a numerical simulation of the tuning of five radioactive beams using three different methods. the beam dynamic is performed through the injection beam line and the cyclotron up to the electrostatic deflector. Within the frame of these methods we have described all the SPIRAL beam diagnostics. Construction and test of a new low intensity diagnosis based on a plastic scintillator for phase measurement inside the cyclotron is described in details. (author). 63 refs.

  5. Development of a machine for sorting laundry according to its radioactive contamination (1962); Conception et mise en oeuvre d'une machine a trier le linge en fonction de sa contamination par des produits radioactifs (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Cohendy, G; Alles, M; Pellerin, A [Commissariat a l' Energie Atomique, Centre de Production de Plutonium, Marcoule (France). Centre d' Etudes Nucleaires

    1962-07-01

    A the Marcoule Plutonium Production Centre special clothing is worn, in the active zones. A large fraction of these clothes is contaminated and must therefore be subjected to specialised treatments during washing in order to be reintroduced subsequently without danger. Because of the large amount of clothes to be treated it has become necessary to install a special semi-automatic machine; the role of the operator is limited to placing the clothing in the machine and to removing the baskets of sorted clothes. The machine itself has been designed and built by the Mechanics Section. The Radiation Protection Service chose the sorting method which is based on {beta} radiation and uses Geiger counters actuating an appropriate electronic system; the Service also developed this system, depending on the various degrees of contamination of the treated clothing. (authors) [French] Le Centre de Production de Plutonium de Marcoule utilise des vetements speciaux pour travailler dans les zones actives. Une proportion importante de ces vetements se contamine et doit, de ce fait, subir des traitements appropries au cours du lavage, de facon a pouvoir etre reintroduits sans danger dans le circuit d'utilisation. Devant l'importance des quantites a traiter, il est apparu necessaire de mettre en place une machine speciale, semi-automatique; le role de l'operateur, consiste en effet uniquement a introduire le linge dans la machine et a extraire de celle-ci les paniers de linge trie. La Section de Mecanique a concu et realise la machine proprement dite. Le Service de Protection contre les Radiations a choisi le mode de tri qui s'effectue en {beta} a l'aide de compteurs Geiger actionnant une electronique appropriee et a assure la mise au point de cette electronique, en fonction des divers degres de contamination du linge a trier. (auteurs)

  6. MUST, a set of strip detectors for studying radioactive beams induced reactions; MUST, un ensemble de detecteurs a pistes pour l`etude des reactions induites par faisceaux radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    Blumenfeld, Y.; Barbier, A.; Beaumel, D.; Charlet, D.; Clavelin, J.F.; Douet, R.; Engrand, M.; Lebon, S.; Lelong, P.; Lesage, A.; Leven, V.; Lhenry, I.; Marechal, F.; Petizon, L.; Pouthas, J.; Richard, A.; Rougier, D.; Soulet, C.; Suomijaervi, T.; Volkov, P.; Voltolini, G. [Paris-11 Univ., 91 - Orsay (France). Inst. de Physique Nucleaire; Auger, F.; Ottini, S.; Alamanos, N. [CEA Centre d`Etudes de Saclay, 91 - Gif-sur-Yvette (France). Dept. d`Astrophysique, de la Physique des Particules, de la Physique Nucleaire et de l`Instrumentation Associee; Sauvestre, J.E.; Bonnereau, B.; Champion, L.; Delbourgo-Salvador, P.; Ethvignot, T.; Szmigiel, M. [CEA Centre d`Etudes de Bruyeres-le-Chatel, 91 (France)

    1996-12-31

    This report states the specificity of light particles elastic scattering, and the need of detecting recoil protons to improve angular resolution. Then the development of a specific MUST strip detector is detailed: 60 strips detectors with Si O sub 2 dielectric, that yield 500 ps time resolution, and Si (Li) detectors following next. A versatile data acquisition system has been developed too, with CAMAC interface to suit to any experimental plant. (D.L.). 27 refs.

  7. Study of radionuclides complexes formation by organic compounds in intermediate and low-level radioactive wastes; Etude de la mobilisation, par des complexants organiques, des radionucleides contenus dans les dechets radioactifs de faible et moyenne activite

    Energy Technology Data Exchange (ETDEWEB)

    Bourbon, X.

    1994-12-01

    In the general framework of the safety of nuclear wastes of low and intermediate activity, we studied the effects of organic compounds on the solubilization of metallic cations. Organic compounds originate from the degradation of cellulose in concrete interstitial waters. Degradation reactions generate a number of products, among which carboxylic acids. These acids are known for their chelating properties. We first analysed the degradation of cellulose in alkaline conditions: we qualitatively and quantitatively determined the degradation products for various reaction progress indices, including a dozen of carboxylic acids. The principal goal of our work was the prediction of the behaviour of metallic cations in such cellulose degradation solutions. Owing the complexity of the system, a priori theoretical calculation are not possible. We have thus decided to choose tetra hydroxy pentanoic acid as a reference compound in order to simulate as accurately as possible the behaviour of more complex acids which contain similar functional groups. We have experimentally determined the complexing properties of this reference acid toward divalent cobalt and copper, and trivalent samarium and europium. Simple and mixed complex (hydroxyl) have been evidenced in alkaline medium. Their stability constants have been determined and extrapolated at zero ionic strength using the SIT theory. These results allowed us to theoretically predict the behaviour of our four reference cations in cellulose degradation products formed in concrete interstitial waters. In parallel, we have measured their solubility in real cellulose degradation solutions. Solubility predictions are correct for transition metals, but not for rare earth cations. In this case the complexes which have been identified with tetra hydroxy pentanoic acid are not stable enough to dissolve metallic hydroxides. In real degradation solutions, other compounds would account for the enhancement of rare earth elements solubility.

  8. Results of several years experiments on the absorption of radioactive strontium and caesium by cultivated plants (1962); Compte rendu d'experiences de plusieurs annees sur l'absorption du strontium et du cesium radioactifs par des plantes cultivees (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Michon, M [Commissariat a l' Energie Atomique, Dept. de Protection Sanitaire, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires; Benard, M; Flanzy, M [Station Centrale de Technologie des Produits Vegetaux, 11 - Narbonne (France); Fioramonti, M; Marty, M [Station Agronomique de Toulouse, 31 (France); Barbier, M; Le Blaye, M; Brossard, M [Societe Centrale d' Agronomie, 78 - Versailles (France)

    1962-07-01

    This report follows on to the report number CEA 1860 and uses results obtained in 1960 to give more precise details concerning the data presented in the preceding report. First results obtained on the vine are given. The Sr absorption coefficient has varied very little from one year to the next and that of caesium has slightly diminished. The values obtained suggest that the concentrations of {sup 90}Sr and {sup 137}Cs in irrigation water should not exceed 1/5 of the maximum permissible concentration in drinking water. (authors) [French] Ce rapport fait suite au rapport CEA 1860 et precise grace aux resultats acquis en 1960 les donnees exprimees dans le precedent rapport. Il y est fait mention des premiers resultats obtenus pour la vigne. Le coefficient d'absorption du Sr a peu varie d'une annee sur l'autre et celui du cesium legerement diminue. Les valeurs obtenues permettent de penser qu'il serait souhaitable que la concentration en {sup 90}Sr et en {sup 137}Cs dans l'eau d'irrigation ne depasse pas le 1/5 de la concentration maxima admissible pour l'eau de boisson. (auteurs)

  9. Radioactive waste combustion / vitrification under arc plasma: thermal and dynamic modelling; Combustion - vitrification de dechets radioactifs par plasma d'arc: modelisation de la thermique et de la dynamique

    Energy Technology Data Exchange (ETDEWEB)

    Barthelemy, B

    2003-07-01

    This thesis concerns the thermal and dynamic modelling for a combustion/vitrification process of surrogate radioactive waste under transferred arc plasma. The writer presents the confinement processes for radioactive waste using arc plasma and the different software used to model theses processes. This is followed by a description of our experimental equipment including a plasma arc reactor and an inductive system allowing the homogenization of glass temperature. A combustion/vitrification test is described. Thermal and material balances were discussed. The temperature fields of plasma arc and the glass frit conductivity are measured. Finally, the writer describes and clarifies the equations solved for the simulations of the electrically plasma arc and the glass melting including the thin layer of glass frit coating the crucible cold walls. The modelling results are presented in the form of spatial distribution of temperature, velocity and volume power... (author)

  10. Radioactive waste combustion-vitrification under arc plasma: thermal and dynamic modelling; Combustion - vitrification de dechets radioactifs par plasma d'arc: modelisation de la thermique et de la dynamique

    Energy Technology Data Exchange (ETDEWEB)

    Barthelemy, B

    2003-06-01

    This thesis concerns the thermal and dynamic modelling for a combustion/vitrification process of surrogate radioactive waste under transferred arc plasma. The writer presents the confinement processes for radioactive waste using arc plasma and the different software used to model theses processes. This is followed by a description of our experimental equipment including a plasma arc reactor and an inductive system allowing the homogenization of glass temperature. A combustion/vitrification test is described. Thermal and material balances were discussed. The temperature fields of plasma arc and the glass frit conductivity are measured. Finally, the writer describes and clarifies the equations solved for the simulations of the electrically plasma arc and the glass melting including the thin layer of glass frit coating the crucible cold walls. The modelling results are presented in the form of spatial distribution of temperature, velocity and voluminal power... (author)

  11. Law project on the radioactive materials and wastes management 2006 recommendations presented by Anne Duthilleul; Projet de loi sur la gestion des matieres et des dechets radioactifs 2006 avis presente par Mme Anne Duthilleul

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-01

    This document provides recommendations on the law project concerning the radioactive material and wastes management. It precises the law objectives, the french particularities concerning the radioactive wastes and materials management, the public debate in France, the evaluation of the researches, the recommendations of the economic and social council. (A.L.B.)

  12. Numerical modeling of the thermomechanical behavior of networks of underground galleries for the storage of the radioactive waste: approach by homogenization; Modelisation numerique du comportement thermomecanique de reseaux de galeries souterraines pour le stockage des dechets radioactifs: Approche par homogeneisation

    Energy Technology Data Exchange (ETDEWEB)

    Zokimila, P

    2005-10-15

    Deep geological disposal is one of the privileged options for the storage of High Level radioactive waste. A good knowledge of the behavior and properties of the potential geological formations as well as theirs evolution in time under the effect of the stress change induced by a possible installation of storage is required. The geological formation host will be subjected to mechanical and thermal solicitations due respectively to the excavation of the disposal tunnels and the release of heat of the canisters of radioactive waste. These thermomechanical solicitations will generate a stress relief in the host layer and disposal tunnels deformations as well as the extension of the damaged zones (EDZ) could cause local and global instabilities. This work aims to develop calculation methods to optimize numerical modeling of the thermoelastic behavior of the disposal at a large scale and to evaluate thermomechanical disturbance induced by storage on the geological formation host. Accordingly, after a presentation of the state of knowledge on the thermomechanical aspects of the rocks related to deep storage, of numerical modeling 2D and 3D of the thermoelastic behavior of individual disposal tunnel and a network of tunnels were carried out by a discrete approach. However, this classical approach is penalizing to study the global behavior of disposal storage. To mitigate that, an approach of numerical modeling, based on homogenization of periodic structures, was proposed. Formulations as numerical procedures were worked out to calculate the effective thermoelastic behavior of an equivalent heterogeneous structure. The model, obtained by this method, was validated with existing methods of homogenization such as the self-consistent model, as well as the Hashin-Shtrikman bounds. The comparison between the effective thermoelastic behavior and current thermoelastic behavior of reference showed a good coherence of the results. For an application to deep geological storage, the effective thermoelastic properties of a network of circular tunnels could be given in 2D for various dimensions of the distance between galleries. (author)

  13. Miniature and low cost fiber Bragg grating interrogator for structural monitoring in nano-satellites

    Science.gov (United States)

    Toet, P. M.; Hagen, R. A. J.; Hakkesteegt, H. C.; Lugtenburg, J.; Maniscalco, M. P.

    2017-11-01

    In this paper we present a newly developed Fiber Optic measurement system, consisting of Fiber Bragg Grating (FBG) sensors and an FBG interrogator. The development of the measuring system is part of the PiezoElectric Assisted Smart Satellite Structure (PEASSS) project, which was initiated at the beginning of 2013 and is financed by the Seventh Framework Program (FP7) of the European Commission. Within the PEASSS project, a Nano-Satellite is being designed and manufactured to be equipped with new technology that will help keep Europe on the cutting edge of space research, potentially reducing the cost and development time for more accurate future sensor platforms including synthetic aperture optics, moving target detection and identification, and compact radars. After on ground testing the satellite is planned to be launched at the end of 2015. Within the satellite, different technologies will be demonstrated on orbit to show their capabilities for different in-space applications. For our application the FBG interrogator monitors the structural and thermal behaviour of a so called "smart panel". These panels will enable fine angle control and thermal and vibration compensation in order to improve all types of future Earth observations, such as environmental and planetary mapping, border and regional imaging. The Fiber Optic (FO) system in PEASSS includes four FBG strain sensors and two FBG temperature sensors. The 3 channel interrogator has to have a small footprint (110x50x40mm), is low cost, low in mass and has a low power consumption. In order to meet all these requirements, an interrogator has been designed based on a tunable Vertical-Cavity Surface-Emitting Laser (VCSEL) enabling a wavelength sweep of around 7 nm. To guarantee the absolute and relative performance, two reference methods are included internally in the interrogator. First, stabilized reference FBG sensors are used to obtain absolute wavelength calibrations. This method is used for the temperature

  14. Don Quijote et Dulcinea, ou quand l’univers fictionnel interroge la réalité de l’amour

    Directory of Open Access Journals (Sweden)

    Odile Lasserre Dempure

    2009-02-01

    Full Text Available Vaste mise en miroir d’une fiction qui n’en finit pas d’interroger son rapport ambigu au réel, le chef d’œuvre de Cervantès place le mouvement dialectique entre univers fictionnel et réalité au cœur même de son écriture. Au sein de cette dialectique, l’amour multiplement fictionnel de don Quichotte pour Dulcinée joue cependant un rôle majeur que ce travail se propose d’examiner. Lieu d’épanouissement privilégié d’un questionnement du rapport entre fiction et réalité, la mise en écriture de cet amour participe en effet de la vaste entreprise de révision des concepts menée par la pensée humaniste : c’est une exploration de la notion même d’amour, de sa réalité, de sa vérité, que permet le voyage au pays de l’amour auquel le Quichotte de Cervantès invite le lecteur.

  15. Phosphorylation of Mycobacterium tuberculosis ParB participates in regulating the ParABS chromosome segregation system.

    Science.gov (United States)

    Baronian, Grégory; Ginda, Katarzyna; Berry, Laurence; Cohen-Gonsaud, Martin; Zakrzewska-Czerwińska, Jolanta; Jakimowicz, Dagmara; Molle, Virginie

    2015-01-01

    Here, we present for the first time that Mycobacterium tuberculosis ParB is phosphorylated by several mycobacterial Ser/Thr protein kinases in vitro. ParB and ParA are the key components of bacterial chromosome segregation apparatus. ParB is a cytosolic conserved protein that binds specifically to centromere-like DNA parS sequences and interacts with ParA, a weak ATPase required for its proper localization. Mass spectrometry identified the presence of ten phosphate groups, thus indicating that ParB is phosphorylated on eight threonines, Thr32, Thr41, Thr53, Thr110, Thr195, and Thr254, Thr300, Thr303 as well as on two serines, Ser5 and Ser239. The phosphorylation sites were further substituted either by alanine to prevent phosphorylation or aspartate to mimic constitutive phosphorylation. Electrophoretic mobility shift assays revealed a drastic inhibition of DNA-binding by ParB phosphomimetic mutant compared to wild type. In addition, bacterial two-hybrid experiments showed a loss of ParA-ParB interaction with the phosphomimetic mutant, indicating that phosphorylation is regulating the recruitment of the partitioning complex. Moreover, fluorescence microscopy experiments performed in the surrogate Mycobacterium smegmatis ΔparB strain revealed that in contrast to wild type Mtb ParB, which formed subpolar foci similar to M. smegmatis ParB, phoshomimetic Mtb ParB was delocalized. Thus, our findings highlight a novel regulatory role of the different isoforms of ParB representing a molecular switch in localization and functioning of partitioning protein in Mycobacterium tuberculosis.

  16. Phosphorylation of Mycobacterium tuberculosis ParB participates in regulating the ParABS chromosome segregation system.

    Directory of Open Access Journals (Sweden)

    Grégory Baronian

    Full Text Available Here, we present for the first time that Mycobacterium tuberculosis ParB is phosphorylated by several mycobacterial Ser/Thr protein kinases in vitro. ParB and ParA are the key components of bacterial chromosome segregation apparatus. ParB is a cytosolic conserved protein that binds specifically to centromere-like DNA parS sequences and interacts with ParA, a weak ATPase required for its proper localization. Mass spectrometry identified the presence of ten phosphate groups, thus indicating that ParB is phosphorylated on eight threonines, Thr32, Thr41, Thr53, Thr110, Thr195, and Thr254, Thr300, Thr303 as well as on two serines, Ser5 and Ser239. The phosphorylation sites were further substituted either by alanine to prevent phosphorylation or aspartate to mimic constitutive phosphorylation. Electrophoretic mobility shift assays revealed a drastic inhibition of DNA-binding by ParB phosphomimetic mutant compared to wild type. In addition, bacterial two-hybrid experiments showed a loss of ParA-ParB interaction with the phosphomimetic mutant, indicating that phosphorylation is regulating the recruitment of the partitioning complex. Moreover, fluorescence microscopy experiments performed in the surrogate Mycobacterium smegmatis ΔparB strain revealed that in contrast to wild type Mtb ParB, which formed subpolar foci similar to M. smegmatis ParB, phoshomimetic Mtb ParB was delocalized. Thus, our findings highlight a novel regulatory role of the different isoforms of ParB representing a molecular switch in localization and functioning of partitioning protein in Mycobacterium tuberculosis.

  17. Development of characterization methods applied to radioactive wastes and waste packages; Le developpement des methodes de caracterisation appliquees aux dechets et colis de dechets radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    Guy, C.; Bienvenu, Ph.; Comte, J.; Excoffier, E.; Dodi, A. [CEA Cadarache (DEN/CAD-DEC/SA3C/LARC), 13 - Saint Paul lez Durance (France); Gal, O.; Gmar, M.; Jeanneau, F.; Poumarede, B.; Tola, F. [CEA Saclay (DRT/SAC-DETECS/SSTM/L2MA), 91 - Gif sur Yvette (France); Moulin, V. [CEA Grenoble (DRT/GRE-LETI/DTBS/STD), 38 (France); Jallu, F.; Lyoussi, A.; Ma, J.L.; Oriol, L.; Passard, Ch.; Perot, B.; Pettier, J.L.; Raoux, A.C.; Thierry, R. [CEA Cadarache (DEN/CAD-DTN/SMTM/LMN), 13 - Saint Paul lez Durance (France)

    2004-07-01

    This document is a compilation of R and D studies carried out in the framework of the axis 3 of the December 1991 law about the conditioning and storage of high-level and long lived radioactive wastes and waste packages, and relative to the methods of characterization of these wastes. This R and D work has permitted to implement and qualify new methods (characterization of long-lived radioelements, high energy imaging..) and also to improve the existing methods by lowering detection limits and reducing uncertainties of measured data. This document is the result of the scientific production of several CEA laboratories that use complementary techniques: destructive methods and radiochemical analyses, photo-fission and active photonic interrogation, high energy imaging systems, neutron interrogation, gamma spectroscopy and active and passive imaging techniques. (J.S.)

  18. Investigations of active interrogation techniques to detect special nuclear material in maritime environments: Standoff interrogation of small- and medium-sized cargo ships

    International Nuclear Information System (INIS)

    Miller, Thomas M.; Patton, Bruce W.; Grogan, Brandon R.; Henkel, James J.; Murphy, Brian D.; Johnson, Jeffrey O.; Mihalczo, John T.

    2013-01-01

    In this work, several active interrogation (AI) sources are evaluated to determine their usefulness in detecting the presence of special nuclear material (SNM) in fishing trawlers, small cargo transport ships, and luxury yachts at large standoff distances from the AI source and detector. This evaluation is performed via computational analysis applying Monte Carlo methods with advanced variance reduction techniques. The goal is to determine the AI source strength required to detect the presence of SNM. The general conclusion of this study is that AI is not reliable when SNM is heavily shielded and not tightly coupled geometrically with the source and detector, to the point that AI should not be considered a via interrogation option in these scenarios. More specifically, when SNM is shielded by hydrogenous material large AI source strengths are required if detection is based on neutrons, which is not surprising. However, if the SNM is shielded by high-Z material the required AI source strengths are not significantly different if detection is based on neutrons or photons, which is somewhat surprising. Furthermore, some of the required AI source strengths that were calculated are very large. These results coupled with the realities of two ships moving independently at sea and other assumptions made during this analysis make the use of standoff AI in the maritime environment impractical

  19. Investigations of active interrogation techniques to detect special nuclear material in maritime environments: Standoff interrogation of small- and medium-sized cargo ships

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Thomas M., E-mail: millertm@ornl.gov; Patton, Bruce W.; Grogan, Brandon R.; Henkel, James J.; Murphy, Brian D.; Johnson, Jeffrey O.; Mihalczo, John T.

    2013-12-01

    In this work, several active interrogation (AI) sources are evaluated to determine their usefulness in detecting the presence of special nuclear material (SNM) in fishing trawlers, small cargo transport ships, and luxury yachts at large standoff distances from the AI source and detector. This evaluation is performed via computational analysis applying Monte Carlo methods with advanced variance reduction techniques. The goal is to determine the AI source strength required to detect the presence of SNM. The general conclusion of this study is that AI is not reliable when SNM is heavily shielded and not tightly coupled geometrically with the source and detector, to the point that AI should not be considered a via interrogation option in these scenarios. More specifically, when SNM is shielded by hydrogenous material large AI source strengths are required if detection is based on neutrons, which is not surprising. However, if the SNM is shielded by high-Z material the required AI source strengths are not significantly different if detection is based on neutrons or photons, which is somewhat surprising. Furthermore, some of the required AI source strengths that were calculated are very large. These results coupled with the realities of two ships moving independently at sea and other assumptions made during this analysis make the use of standoff AI in the maritime environment impractical.

  20. [Ambroise Paré in French literature].

    Science.gov (United States)

    Dumaitre, P

    1995-01-01

    The 16th century by its passionate side has been the favourite one of authors of historical novels in which among the heroes of "cloak and dagger stories" appears sometime Ambroise Paré. Alexandre Dumas (the father) has shown him at the court of Charles IX in La Reine Margot (1845) where he does not however play a great role. On the contrary, Balzac in Le Martyr calviniste (1842) has given him a capital part close to the dying François II, whom he intended to trepanize but had to give up this idea as a consequence of the opposition of the queen-mother Catherine de Médicis. In the present century, Robert Merle in Paris ma bonne ville (Fortune de France, 3, 1980) shows Paré at the time of the Saint Barthélemy.

  1. Par Pond refill water quality sampling

    International Nuclear Information System (INIS)

    Koch, J.W. II; Martin, F.D.; Westbury, H.M.

    1996-08-01

    This study was designed to document anoxia and its cause in the event that the anoxia caused a fish kill. However, no fish kill was observed during this study, and dissolved oxygen and nutrient concentrations generally remained within the range expected for southeastern reservoirs. Par Pond water quality monitoring will continue during the second summer after refill as the aquatic macrophytes become reestablished and nutrients in the sediments are released to the water column

  2. Interrogation of fibre Bragg gratings through a fibre optic rotary joint on a geotechnical centrifuge

    Science.gov (United States)

    Correia, Ricardo; James, Stephen W.; Marshall, Alec; Heron, Charles; Korposh, Sergiy

    2016-05-01

    The monitoring of an array of fibre Bragg gratings (FBGs) strain sensors was performed through a single channel, single mode fibre optic rotary joint (FORJ) mounted on a geotechnical centrifuge. The array of three FBGs was attached to an aluminum plate that was anchored at the ends and placed on the model platform of the centrifuge. Acceleration forces of up to 50g were applied and the reflection signal of the monitored FBGs recorded dynamically using a 2.5kHz FBG interrogator placed outside the centrifuge. The use of a FORJ allowed the monitoring of the FBGs without submitting the FBG interrogator to the high g-forces experienced in the centrifuge.

  3. Psychologists and detainee interrogations: key decisions, opportunities lost, and lessons learned.

    Science.gov (United States)

    Pope, Kenneth S

    2011-01-01

    After the 9-11 terrorist attacks, U.S. psychologists faced hard choices about what roles, if any, were appropriate for psychologists in the detainee interrogations conducted in settings such as the Bagram Airbase, the Abu Ghraib Prison, and the Guantanamo Bay Detention Camps. The American Psychological Association (APA) sparked intense controversy with its policies and public statements. This article reviews APA decisions, documents, and public statements in this area, in the context of major criticisms and responses to those criticisms. The review focuses on key issues: how the APA created and reported policies in the areas of ethics and national security; transparency; psychologists' professional identities; psychologists' qualifications; ethical-legal conflicts; policies opposing torture; interpretations of avoiding harm; and effective interrogations. It suggests lessons learned, missed opportunities, and questions in need of a fresh approach. © 2011 by Annual Reviews. All rights reserved

  4. Enhanced-locality fiber-optic two-photon-fluorescence live-brain interrogation

    Energy Technology Data Exchange (ETDEWEB)

    Fedotov, I. V.; Doronina-Amitonova, L. V. [International Laser Center, Physics Department, M.V. Lomonosov Moscow State University, Moscow 119992 (Russian Federation); Russian Quantum Center, ul. Novaya 100, Skolkovo, Moscow Region 1430125 (Russian Federation); Kurchatov Institute National Research Center, Moscow (Russian Federation); Sidorov-Biryukov, D. A.; Fedotov, A. B. [International Laser Center, Physics Department, M.V. Lomonosov Moscow State University, Moscow 119992 (Russian Federation); Russian Quantum Center, ul. Novaya 100, Skolkovo, Moscow Region 1430125 (Russian Federation); Anokhin, K. V. [Kurchatov Institute National Research Center, Moscow (Russian Federation); P.K. Anokhin Institute of Normal Physiology, Russian Academy of Medical Sciences, Moscow (Russian Federation); Kilin, S. Ya. [B.I. Stepanov Institute of Physics, National Academy of Sciences of Belarus, Minsk (Belarus); Sakoda, K. [National Institute for Materials Science, 1-1 Namiki, Tsukuba 305-0044 (Japan); Zheltikov, A. M. [International Laser Center, Physics Department, M.V. Lomonosov Moscow State University, Moscow 119992 (Russian Federation); Russian Quantum Center, ul. Novaya 100, Skolkovo, Moscow Region 1430125 (Russian Federation); Department of Physics and Astronomy, Texas A and M University, College Station, Texas 77843 (United States); Center of Photochemistry, Russian Academy of Sciences, ul. Novatorov 7a, Moscow 117421 (Russian Federation)

    2014-02-24

    Two-photon excitation is shown to substantially enhance the locality of fiber-based optical interrogation of strongly scattering biotissues. In our experiments, a high-numerical-aperture, large-core-are fiber probe is used to deliver the 200-fs output of a 100-MHz mode-locked ytterbium fiber laser to samples of live mouse brain, induce two-photon fluorescence of nitrogen–vacancy centers in diamond markers in brain sample. Fiber probes with a high numerical aperture and a large core area are shown to enable locality enhancement in fiber-laser–fiber-probe two-photon brain excitation and interrogation without sacrificing the efficiency of fluorescence response collection.

  5. PRESTO-Tango as an open-source resource for interrogation of the druggable human GPCRome.

    Science.gov (United States)

    Kroeze, Wesley K; Sassano, Maria F; Huang, Xi-Ping; Lansu, Katherine; McCorvy, John D; Giguère, Patrick M; Sciaky, Noah; Roth, Bryan L

    2015-05-01

    G protein-coupled receptors (GPCRs) are essential mediators of cellular signaling and are important targets of drug action. Of the approximately 350 nonolfactory human GPCRs, more than 100 are still considered to be 'orphans' because their endogenous ligands remain unknown. Here, we describe a unique open-source resource that allows interrogation of the druggable human GPCRome via a G protein-independent β-arrestin-recruitment assay. We validate this unique platform at more than 120 nonorphan human GPCR targets, demonstrate its utility for discovering new ligands for orphan human GPCRs and describe a method (parallel receptorome expression and screening via transcriptional output, with transcriptional activation following arrestin translocation (PRESTO-Tango)) for the simultaneous and parallel interrogation of the entire human nonolfactory GPCRome.

  6. Characterization of FBG sensor interrogation based on a FDML wavelength swept laser

    Science.gov (United States)

    Jung, Eun Joo; Kim, Chang-Seok; Jeong, Myung Yung; Kim, Moon Ki; Jeon, Min Yong; Jung, Woonggyu; Chen, Zhongping

    2012-01-01

    In this study, we develop an ultra-fast fiber Bragg grating sensor system that is based on the Fourier domain mode-locked (FDML) swept laser. A FDML wavelength swept laser has many advantages compared to the conventional wavelength swept laser source, such as high-speed interrogation, narrow spectral sensitivity, and high phase stability. The newly developed FDML wavelength swept laser shows a superior performance of a high scan rate of 31.3 kHz and a broad scan range of over 70 nm simultaneously. The performance of the grating sensor interrogating system using a FDML wavelength swept laser is characterized in both static and dynamic strain responses. PMID:18852764

  7. Novel birefringence interrogation for Sagnac loop interferometer sensor with unlimited linear measurement range.

    Science.gov (United States)

    He, Haijun; Shao, Liyang; Qian, Heng; Zhang, Xinpu; Liang, Jiawei; Luo, Bin; Pan, Wei; Yan, Lianshan

    2017-03-20

    A novel demodulation method for Sagnac loop interferometer based sensor has been proposed and demonstrated, by unwrapping the phase changes with birefringence interrogation. A temperature sensor based on Sagnac loop interferometer has been used to verify the feasibility of the proposed method. Several tests with 40 °C temperature range have been accomplished with a great linearity of 0.9996 in full range. The proposed scheme is universal for all Sagnac loop interferometer based sensors and it has unlimited linear measurable range which overwhelming the conventional demodulation method with peak/dip tracing. Furthermore, the influence of the wavelength sampling interval and wavelength span on the demodulation error has been discussed in this work. The proposed interrogation method has a great significance for Sagnac loop interferometer sensor and it might greatly enhance the availability of this type of sensors in practical application.

  8. Guidelines for calculating and enhancing detection efficiency of PIT tag interrogation systems

    Science.gov (United States)

    Connolly, Patrick J.

    2010-01-01

    With increasing use of passive integrated transponder (PIT) tags and reliance on stationary PIT tag interrogation systems to monitor fish populations, guidelines are offered to inform users how best to use limited funding and human resources to create functional systems that maximize a desired level of detection and precision. The estimators of detection efficiency and their variability as described by Connolly et al. (2008) are explored over a span of likely performance metrics. These estimators were developed to estimate detection efficiency without relying on a known number of fish passing the system. I present graphical displays of the results derived from these estimators to show the potential efficiency and precision to be gained by adding an array or by increasing the number of PIT-tagged fish expected to move past an interrogation system.

  9. Functional interrogation of non-coding DNA through CRISPR genome editing.

    Science.gov (United States)

    Canver, Matthew C; Bauer, Daniel E; Orkin, Stuart H

    2017-05-15

    Methodologies to interrogate non-coding regions have lagged behind coding regions despite comprising the vast majority of the genome. However, the rapid evolution of clustered regularly interspaced short palindromic repeats (CRISPR)-based genome editing has provided a multitude of novel techniques for laboratory investigation including significant contributions to the toolbox for studying non-coding DNA. CRISPR-mediated loss-of-function strategies rely on direct disruption of the underlying sequence or repression of transcription without modifying the targeted DNA sequence. CRISPR-mediated gain-of-function approaches similarly benefit from methods to alter the targeted sequence through integration of customized sequence into the genome as well as methods to activate transcription. Here we review CRISPR-based loss- and gain-of-function techniques for the interrogation of non-coding DNA. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Causal Interrogation of Neuronal Networks and Behavior through Virally Transduced Ivermectin Receptors.

    Science.gov (United States)

    Obenhaus, Horst A; Rozov, Andrei; Bertocchi, Ilaria; Tang, Wannan; Kirsch, Joachim; Betz, Heinrich; Sprengel, Rolf

    2016-01-01

    The causal interrogation of neuronal networks involved in specific behaviors requires the spatially and temporally controlled modulation of neuronal activity. For long-term manipulation of neuronal activity, chemogenetic tools provide a reasonable alternative to short-term optogenetic approaches. Here we show that virus mediated gene transfer of the ivermectin (IVM) activated glycine receptor mutant GlyRα1 (AG) can be used for the selective and reversible silencing of specific neuronal networks in mice. In the striatum, dorsal hippocampus, and olfactory bulb, GlyRα1 (AG) promoted IVM dependent effects in representative behavioral assays. Moreover, GlyRα1 (AG) mediated silencing had a strong and reversible impact on neuronal ensemble activity and c-Fos activation in the olfactory bulb. Together our results demonstrate that long-term, reversible and re-inducible neuronal silencing via GlyRα1 (AG) is a promising tool for the interrogation of network mechanisms underlying the control of behavior and memory formation.

  11. Guidelines to indirectly measure and enhance detection efficiency of stationary PIT tag interrogation systems in streams

    Science.gov (United States)

    Connolly, Patrick J.; Wolf, Keith; O'Neal, Jennifer S.

    2010-01-01

    With increasing use of passive integrated transponder (PIT) tags and reliance on stationary PIT tag interrogation systems to monitor fish populations, guidelines are offered to inform users how best to use limited funding and human resources to create functional systems that maximize a desired level of detection and precision. The estimators of detection efficiency and their variability as described by Connolly et al. (2008) are explored over a span of likely performance metrics. These estimators were developed to estimate detection efficiency without relying on a known number of fish passing the system. I present graphical displays of the results derived from these estimators to show the potential efficiency and precision to be gained by adding an array or by increasing the number of PIT-tagged fish expected to move past an interrogation system.

  12. Wavelength interrogation of fiber Bragg grating sensors based on crossed optical Gaussian filters.

    Science.gov (United States)

    Cheng, Rui; Xia, Li; Zhou, Jiaao; Liu, Deming

    2015-04-15

    Conventional intensity-modulated measurements require to be operated in linear range of filter or interferometric response to ensure a linear detection. Here, we present a wavelength interrogation system for fiber Bragg grating sensors where the linear transition is achieved with crossed Gaussian transmissions. This unique filtering characteristic makes the responses of the two branch detections follow Gaussian functions with the same parameters except for a delay. The substraction of these two delayed Gaussian responses (in dB) ultimately leads to a linear behavior, which is exploited for the sensor wavelength determination. Beside its flexibility and inherently power insensitivity, the proposal also shows a potential of a much wider operational range. Interrogation of a strain-tuned grating was accomplished, with a wide sensitivity tuning range from 2.56 to 8.7 dB/nm achieved.

  13. Interrogation cradle and insertable containment fixture for detecting birefringent microcrystals in bile

    Science.gov (United States)

    Darrow, Chris; Seger, Tino

    2003-09-30

    A transparent flow channel fluidly communicates a fluid source and a collection reservoir. An interrogating light beam passes through a first polarizer having a first plane of polarization. The flow channel is orthogonal to the light beam. The light beam passes through a fluid sample as it flows through the flow channel, and is then filtered through a second polarizer having a second plane of polarization rotated 90.degree. from the first plane of polarization. An electronic photo-detector is aligned with the light beam, and signals the presence of birefringent microcrystals in the fluid sample by generating voltage pulses. A disposable containment fixture includes the flow channel and the collection reservoir. The fixture is adapted for removable insertion into an interrogation cradle that includes optical and data processing components. The cradle rigidly positions the centerline of the flow channel orthogonal to the light beam.

  14. Interrogative pressure in simulated forensic interviews: the effects of negative feedback.

    Science.gov (United States)

    McGroarty, Allan; Baxter, James S

    2007-08-01

    Much experimental research on interrogative pressure has concentrated on the effects of leading questions, and the role of feedback in influencing responses in the absence of leading questions has been neglected by comparison. This study assessed the effect of negative feedback and the presence of a second interviewer on interviewee responding in simulated forensic interviews. Participants viewed a videotape of a crime, answered questions about the clip and were requestioned after receiving feedback. Compared with neutral feedback, negative feedback resulted in more response changes, higher reported state anxiety and higher ratings of interview difficulty. These results are consistent with Gudjonsson and Clark's (1986) model of interrogative suggestibility. The presence and involvement of a second interviewer did not significantly affect interviewee responding, although trait anxiety scores were elevated when a second interviewer was present. The theoretical and applied implications of these findings are considered.

  15. Examining the role of interrogative suggestibility in Miranda rights comprehension in adolescents.

    Science.gov (United States)

    McLachlan, Kaitlyn; Roesch, Ronald; Douglas, Kevin S

    2011-06-01

    This study aimed to further clarify the association between interrogative suggestibility and Miranda rights comprehension in adolescents; in particular, we examined whether intellectual ability (IQ) serves as a mediator of this relationship. Participants completed Grisso's Miranda Instruments, the Wechsler Abbreviated Scale of Intelligence, and the Gudjonsson Suggestibility Scale. Many youth demonstrated poor comprehension of their rights, particularly younger and less intellectually capable adolescents. Both yield and shift components of interrogative suggestibility were inversely related to rights comprehension; however, IQ fully mediated these relationships. Neither demographic variables (gender, ethnicity, socio-economic status after controlling for IQ, and English as a second language (ESL) status) nor previous police experience were significantly associated with rights comprehension in the present sample. The implications of these findings are discussed.

  16. Interrogative suggestibility: its relationship with assertiveness, social-evaluative anxiety, state anxiety and method of coping.

    Science.gov (United States)

    Gudjonsson, G H

    1988-05-01

    This paper attempts to investigate empirically in 30 subjects some of the theoretical components related to individual differences that are thought by Gudjonsson & Clark (1986) to mediate interrogative suggestibility as measured by the Gudjonsson Suggestibility Scale (GSS; Gudjonsson, 1984a). The variables studied were: assertiveness, social-evaluative anxiety, state anxiety and the coping methods subjects are able to generate and implement during interrogation. Low assertiveness and high evaluative anxiety were found to correlate moderately with suggestibility, but no significant correlations emerged for 'social avoidance and distress'. State anxiety correlated significantly with suggestibility, particularly after negative feedback had been administered. Coping methods (active-cognitive/behavioural vs. avoidance) significantly predicted suggestibility scores. The findings give strong support to the theoretical model of Gudjonsson & Clark.

  17. Syncope During Competitive Events: Interrogating Heart Rate Monitor Watches May Be Useful!

    Science.gov (United States)

    Thabouillot, Oscar; Bostanci, Kevin; Bouvier, Francois; Dumitrescu, Nicolae; Stéfuriac, Maria; Paule, Philippe; Roche, Nicolas-Charles

    2017-12-01

    This is a case report of a 45-year-old man who reported complete amnesia during the very first kilometer of a 10-km run. He was wearing a heart rate monitor (HRM). The interrogation of his HRM watch showed 200 bpm tachycardia beginning in the first kilometer and increasing up to 220 bpm during the last kilometer. The patient was asked to wear a Holter-monitor (Holter Research Laboratory; Helena, Montana USA) electrocardiogram (ECG) while practicing a training session. This examination allowed for the diagnosis of an adrenergic paroxysmal atrial fibrillation (AF) with an impressive auriculo-ventricular conduction over 260 bpm. This case highlights that non-medical devices, such as connected watches, can be helpful to diagnose arrhythmias. Thabouillot O , Bostanci K , Bouvier F , Dumitrescu N , Stéfuriac M , Paule P , Roche NC . Syncope during competitive events: interrogating heart rate monitor watches may be useful! Prehosp Disaster Med. 2017;32(6):691-693.

  18. Ortho-Babinet polarization-interrogating filter: an interferometric approach to polarization measurement.

    Science.gov (United States)

    Van Delden, Jay S

    2003-07-15

    A novel, interferometric, polarization-interrogating filter assembly and method for the simultaneous measurement of all four Stokes parameters across a partially polarized irradiance image in a no-moving-parts, instantaneous, highly sensitive manner is described. In the reported embodiment of the filter, two spatially varying linear retarders and a linear polarizer comprise an ortho-Babinet, polarization-interrogating (OBPI) filter. The OBPI filter uniquely encodes the incident ensemble of electromagnetic wave fronts comprising a partially polarized irradiance image in a controlled, deterministic, spatially varying manner to map the complete state of polarization across the image to local variations in a superposed interference pattern. Experimental interferograms are reported along with a numerical simulation of the method.

  19. The Public Health Problems of Nuclear Waste Disposal; L'Elimination des Dechets Radioactifs et la Sante Publique; 041f 0420 041e 0414 ; Problemas que Presenta para la Salud Publica la Evacuacion de Desechos Radiactivos

    Energy Technology Data Exchange (ETDEWEB)

    Dunster, H. J. [United Kingdom Atomic Energy Authority, Health and Safety Branch (United Kingdom)

    1960-07-01

    The fundamental bases of the control of public health problems in connexion with the disposal of radioactive wastes are the Recommendations of the International Commission on Radiological Protection. These Recommendations cannot be applied directly to the disposal of waste because the released radioactivity rarely reaches man in a direct manner. The setting of maximum permissible discharge rates, therefore, involves a knowledge not only of man's utilization of his environment but also of the diverse processes which govern the behaviour of radioactive materials in that environment. As an example of the way in which the United Kingdom has dealt with these problems the paper discusses the discharge of low-activity liquid wastes into the sea, and refers briefly to the similar problems of assessing discharges into rivers and disposal into the ground or the deep sea. The paper concludes that it is possible to demonstrate without difficulty the safety of most proposed waste-disposal operations but that meticulous investigation and control are necessary whenever substantial amounts of radioactivity are to be released to man's environment. (author) [French] Les donnees de base relatives aux mesure de sante publique touchant l'elimination des dechets radioactifs sont fournies par les recommandations de la Commission internationale de protection radiologique. Mais ces recommandations ne peuvent pas etre directement appliquees a l'elimination des dechets, car il est rare que l'homme se trouve directement expose aux radiations emises. Pour pouvoir fixer, en matiere d'elimination de dechets, un taux maximum admissible, il faut donc connaitre non seulement le comportement de l'homme dans le milieu considere, mais aussi les processus suivant lesquels les matieres radioactives agissent sur ce milieu. Prenant comme exemple ce qui est fait au Royaume-Uni, l'auteur etudie la question de l'evacuation dans la mer de dechets liquides de faible radioactivite et il donne un apercu des

  20. Centromere pairing by a plasmid-encoded type I ParB protein

    DEFF Research Database (Denmark)

    Ringgaard, Simon; Löwe, Jan; Gerdes, Kenn

    2007-01-01

    The par2 locus of Escherichia coli plasmid pB171 encodes two trans-acting proteins, ParA and ParB, and two cis-acting sites, parC1 and parC2, to which ParB binds cooperatively. ParA is related to MinD and oscillates in helical structures and thereby positions ParB/parC-carrying plasmids regularly......, hence identifying the N terminus of ParB as a requirement for ParB-mediated centromere pairing. These observations suggest that centromere pairing is an important intermediate step in plasmid partitioning mediated by the common type I loci....

  1. The ethics of interrogation and the American Psychological Association: A critique of policy and process

    OpenAIRE

    Olson, Brad; Soldz, Stephen; Davis, Martha

    2008-01-01

    Abstract The Psychological Ethics and National Security (PENS) task force was assembled by the American Psychological Association (APA) to guide policy on the role of psychologists in interrogations at foreign detention centers for the purpose of U.S. national security. The task force met briefly in 2005, and its report was quickly accepted by the APA Board of Directors and deemed consistent with the APA Ethics Code by the APA Ethics Committee. This rapid acceptance was unusual for a number o...

  2. Knowingly but naively: The overpowering influence of innocence on interrogation rights decision-making.

    Science.gov (United States)

    Scherr, Kyle C; Normile, Christopher J; Bierstetel, Sabrina J; Franks, Andrew S; Hawkins, Ian

    2018-02-01

    Most suspects waive the guaranteed protections that interrogation rights afford them against police intimidation. One factor thought to motivate suspects' inclination to waive their rights stems from the acquiescence bias whereby suspects mindlessly comply with interrogators' requests. However, research bearing on the phenomenology of innocence has demonstrated the power of innocents' mindset, which could motivate some innocent suspects to waive their rights knowingly (instead of mindlessly complying). To test these ideas, participants (N = 178) were (a) rightfully (guilty) or wrongfully (innocent) accused of wrongdoing during an experimental session, (b) administered 1 of 2 forms that by signing either waived or invoked their rights to a student advocate, and (c) given questions to assess their degree of knowing during the decision-making process (i.e., extent to which individuals were cognizant of their decisions). Results demonstrated that unknowing innocent and guilty individuals tended to passively comply, engaging in a pre-interrogation acquiescence bias by signing waive and invoke forms at similar rates. But, as participants became more cognizant of their decisions, they acquiesced at lower rates and their change from acquiescence differed depending on their status. As innocents became more cognizant, they signed the waiver form at higher rates than the invoke form, thereby demonstrating that innocence can motivate some suspects to knowingly forgo their rights. Conversely, as guilty individuals became more cognizant, they signed the invoke form at higher rates than the waiver form. These findings have implications for reforming pre-interrogation protocols, protecting suspects' civil liberties, and preventing innocents from offering false self-incriminating evidence. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  3. Detection of actinides with an electron accelerator by active photoneutron interrogation measurements

    International Nuclear Information System (INIS)

    Sari, A.; Carrel, F.; Gmar, M.; Laine, F.; Normand, S.; Lyoussi, A.

    2012-01-01

    The solution for management of a nuclear waste package is chosen according to its radiological characteristics. One of the most important of these features is the α-activity which is due to actinides ( 235 U, 238 U, 239 Pu, etc.) If non-destructive passive methods are not sufficient to quantify the latter, non-destructive active methods based on the fission process represent a solution of interest. First, these methods consist in irradiating a package in order to induce fission reactions on the actinides, and then, to detect the prompt and delayed particles which are emitted following these reactions. Our aim is to conduct neutron interrogation measurements on nuclear waste packages using an electron accelerator as a photoneutron generator. One of the main interests of this approach is that the intensity of the neutron flux can be one or two orders of magnitude higher than the one delivered by a deuterium-tritium generator. With the objective of improving nuclear waste characterization, the development of this method could enable the integration of three complementary techniques on a single measurement cell (active neutron interrogation, active photon interrogation, and high-energy imaging). In this paper, simulation and experimental results are presented. A simulation study using MCNPX has been conducted in order to determine the characteristics of the photoneutron flux emitted by the electron accelerator of the SAPHIR facility owned by CEA LIST. Energy spectra, angular distribution and intensity of the photoneutron flux have been obtained. A photoneutron interrogation measurement cell based on this accelerator has been built and assessed by carrying out measurements on uranium samples. Delayed gamma-ray spectra have been acquired and enabled to confirm the experimental feasibility of our method. (authors)

  4. Cellular Interrogation: Exploiting Cell-to-Cell Variability to Discriminate Regulatory Mechanisms in Oscillatory Signalling.

    Science.gov (United States)

    Estrada, Javier; Andrew, Natalie; Gibson, Daniel; Chang, Frederick; Gnad, Florian; Gunawardena, Jeremy

    2016-07-01

    The molecular complexity within a cell may be seen as an evolutionary response to the external complexity of the cell's environment. This suggests that the external environment may be harnessed to interrogate the cell's internal molecular architecture. Cells, however, are not only nonlinear and non-stationary, but also exhibit heterogeneous responses within a clonal, isogenic population. In effect, each cell undertakes its own experiment. Here, we develop a method of cellular interrogation using programmable microfluidic devices which exploits the additional information present in cell-to-cell variation, without requiring model parameters to be fitted to data. We focussed on Ca2+ signalling in response to hormone stimulation, which exhibits oscillatory spiking in many cell types and chose eight models of Ca2+ signalling networks which exhibit similar behaviour in simulation. We developed a nonlinear frequency analysis for non-stationary responses, which could classify models into groups under parameter variation, but found that this question alone was unable to distinguish critical feedback loops. We further developed a nonlinear amplitude analysis and found that the combination of both questions ruled out six of the models as inconsistent with the experimentally-observed dynamics and heterogeneity. The two models that survived the double interrogation were mathematically different but schematically identical and yielded the same unexpected predictions that we confirmed experimentally. Further analysis showed that subtle mathematical details can markedly influence non-stationary responses under parameter variation, emphasising the difficulty of finding a "correct" model. By developing questions for the pathway being studied, and designing more versatile microfluidics, cellular interrogation holds promise as a systematic strategy that can complement direct intervention by genetics or pharmacology.

  5. Nanochannel Electroporation as a Platform for Living Cell Interrogation in Acute Myeloid Leukemia.

    Science.gov (United States)

    Zhao, Xi; Huang, Xiaomeng; Wang, Xinmei; Wu, Yun; Eisfeld, Ann-Kathrin; Schwind, Sebastian; Gallego-Perez, Daniel; Boukany, Pouyan E; Marcucci, Guido I; Lee, Ly James

    2015-12-01

    A living cell interrogation platform based on nanochannel electroporation is demonstrated with analysis of RNAs in single cells. This minimally invasive process is based on individual cells and allows both multi-target analysis and stimulus-response analysis by sequential deliveries. The unique platform possesses a great potential to the comprehensive and lysis-free nucleic acid analysis on rare or hard-to-transfect cells.

  6. Technician-Supported Remote Interrogation of CIEDs: Initial Use in US Emergency Departments and Perioperative Areas.

    Science.gov (United States)

    Ahmed, Imdad; Patel, Amisha S; Balgaard, Timothy J; Rosenfeld, Lynda E

    2016-03-01

    Interrogation/interpretation of cardiac implantable electronic devices (CIEDs) is frequently required in the emergency department (ED) or perioperative areas (OR) where resources to do this are often not available. CareLink Express (CLE; Medtronic, plc, Mounds View, MN, USA) is a technician-supported real-time remote interrogation system for Medtronic CIEDs. Using data from 136 US locations, this retrospective study was designed to assess CLE efficiency compared to traditional device management, and examine its findings. All 7,044 US CLE transmissions from the ED and OR (January 2012-October 2014) were compared to 217 traditional requests where CIED interrogations/interpretations were performed by calling industry representatives to these sites. CLE reduced the time to device interrogation/interpretation by 78%: 100 ± 140-22 ± 14 minutes, P < 0.0001, improving response time and consistency; ED: 82 ± 103-23 ± 18 minutes, P, ≤ 0.01; OR: 127 ± 181-17 ± 10 minutes, P < 0.0001. Actionable events (AE) (arrhythmia, device/lead abnormalities) were infrequent: 9.1% overall (ED: 9.9%; OR: 4.1%). Only 6.5% of patients with syncope/presyncope and 13.6% with a perceived shock had AE. AEs were more common in those with suspected device problems (30.4%) or audible alerts (52.6%). They were more likely in patients not enrolled in long-term remote monitoring (23.9% vs 8.2%, P < 0.0001) and in those with older CIED systems (7.4% in year 1 vs 31.0% after 10 years). The many patients with CIEDs, and the ability to quickly identify the minority with high-risk AE from the no/low-risk majority, strongly support CLE use in the ED and OR, sites which are expensive and prioritize efficiency. © 2015 Wiley Periodicals, Inc.

  7. An improved ATAC-seq protocol reduces background and enables interrogation of frozen tissues.

    Science.gov (United States)

    Corces, M Ryan; Trevino, Alexandro E; Hamilton, Emily G; Greenside, Peyton G; Sinnott-Armstrong, Nicholas A; Vesuna, Sam; Satpathy, Ansuman T; Rubin, Adam J; Montine, Kathleen S; Wu, Beijing; Kathiria, Arwa; Cho, Seung Woo; Mumbach, Maxwell R; Carter, Ava C; Kasowski, Maya; Orloff, Lisa A; Risca, Viviana I; Kundaje, Anshul; Khavari, Paul A; Montine, Thomas J; Greenleaf, William J; Chang, Howard Y

    2017-10-01

    We present Omni-ATAC, an improved ATAC-seq protocol for chromatin accessibility profiling that works across multiple applications with substantial improvement of signal-to-background ratio and information content. The Omni-ATAC protocol generates chromatin accessibility profiles from archival frozen tissue samples and 50-μm sections, revealing the activities of disease-associated DNA elements in distinct human brain structures. The Omni-ATAC protocol enables the interrogation of personal regulomes in tissue context and translational studies.

  8. Design of a fiber-optic interrogator module for telecommunication satellites

    Science.gov (United States)

    Putzer, Philipp; Koch, Alexander W.; Plattner, Markus; Hurni, Andreas; Manhart, Markus

    2017-11-01

    In this paper we present the results of the radiation tests performed on the optical components of the fiber-optic interrogator module as a part of the Hybrid Sensor Bus (HSB) system. The HSB-system is developed in the frame of an ESAARTES program and will be verified as flight demonstrator onboard the German Heinrich Hertz satellite in 2016. The HSB system is based on a modular concept which includes sensor interrogation modules based on I2C electrical and fiber Bragg grating (FBG) fiber-optical sensor elements. Onboard fiber-optic sensing allows the implementation of novel control and monitoring methods. For read-out of multiple FBG sensors, a design based on a tunable laser diode as well as a design based on a spectrometer is considered. The expected and tested total ionizing dose (TID) applicable to the HSB system is in the range between 100 krad and 300 krad inside the satellite in the geostationary orbit over a life time of 15 years. We present radiation test results carried out on critical optical components to be used in the fiber-optic interrogation module. These components are a modulated grating Y-branch (MGY) tunable laser diode acting as light source for the tuning laser approach, the line detector of a spectrometer, photodetectors and the FBG sensors acting as sensor elements. A detailed literature inquiry of radiation effects on optical fibers and FBG sensors, is also included in the paper. The fiber-optic interrogator module implemented in the HSB system is based on the most suitable technology, which sustains the harsh environment in the geostationary orbit.

  9. Optically powered and interrogated rotary position sensor for aircraft engine control applications

    Science.gov (United States)

    Spillman, W. B.; Crowne, D. H.; Woodward, D. W.

    A throttle level angle (TLA) sensing system is described that utilizes a capacitance based rotary position transducer that is powered and interrogated via light from a single multimode optical fiber. The system incorporates a unique GaAs device that serves as both a power converter and optical data transmitter. Design considerations are discussed, and the fabrication and performance of the sensor system are detailed.

  10. High spatial and temporal resolution interrogation of fully distributed chirped fiber Bragg grating sensors

    OpenAIRE

    Ahmad, Eamonn J.; Wang, Chao; Feng, Dejun; Yan, Zhijun; Zhang, Lin

    2017-01-01

    A novel interrogation technique for fully distributed linearly chirped fiber Bragg grating (LCFBG) strain sensors with simultaneous high temporal and spatial resolution based on optical time-stretch frequency-domain reflectometry (OTS-FDR) is proposed and experimentally demonstrated. LCFBGs is a promising candidate for fully distributed sensors thanks to its longer grating length and broader reflection bandwidth compared to normal uniform FBGs. In the proposed system, two identical LCFBGs are...

  11. An Alternative Approach: Examining Arguments Against Coercive Interrogation Techniques from a Biblical-Ethics Perspective

    Science.gov (United States)

    2016-06-10

    Ethics of Torture. Jeffreys is Associate Professor of Humanistic Studies and Religion at the University of Wisconsin, Green Bay (Jeffreys 2009... existential struggle of those suffering from MI is a result of “perpetrating, failing to prevent, or bearing witness to acts that transgress deeply held... existential impact of CIT on the interrogator. While neither offers a complete and substantiated theory, their comments provide further argumentation that

  12. Heating of leads casks. An analytical solution to the heat equation made up of a series of Laguerre functions; Echauffement des chateaux de plomb. Une solution analytique a l'equation de la chaleur constituee par une serie de fonctions de Laguerre

    Energy Technology Data Exchange (ETDEWEB)

    Formery, Ph; Gilles, A [Commissariat a l' Energie Atomique, Dir. des Productions, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1968-07-01

    The packing used for the transport of highly radioactive materials such as in-pile irradiated rods; have to comply to fairly strict safety standards. They should in particular resist to fire without the radioactive protection being seriously affected. The heating of a transport cask placed in a fire has been calculated by normal automatic computation methods assuming that only thermal radiation is responsible for the heating and that this obeys STEFAN'S law. Simultaneously, a purely analytical treatment has been attempted as follows. The existence of a simple solution, of the Laguerre function type, to the heat equation has been demonstrated. By superposing an infinite number of simple solutions, it is possible to produce a fairly general solution, depending on parameters, which satisfies the initial state and the limiting conditions. The parameters can be adjusted so that the temperature and the flux produced on the shell by this solution satisfy approximately STEFAN'S relationship. (authors) [French] Les emballages qui servent au transport de produits fortement radioactifs, tels que des barreaux irradies dans les piles, doivent satisfaire a des normes de securite assez strictes. Ils doivent, en particulier, resister au feu sans que la protection contre le rayonnement soit sensiblement entamee. L'echauffement, par seul rayonnement thermique suppose obeir a la loi de STEFAN, d'un chateau de transport plonge dans un feu a ete calcule par les methodes habituelles du calcul automatique. Parallelement a ete tentee l'approche purement analytique que voici: Une solution simple, du type fonction de LAGUERRE, a l'equation de la chaleur est mise en evidence. La superposition, en nombre infini, de solutions simples, permet de fabriquer une solution assez generale dependant de parametres, satisfaisant a l'etat initial et aux conditions aux limites. Les parametres peuvent etre ajustes de facon que la temperature et le flux engendres sur la coque par cette solution

  13. Localizing by autoradiography at -195 deg radioactive areas in rats exposed to a high flux of thermal neutrons, importance of phosphorus 32 in consecutive internal irradiation; Localisation par autoradiographie a -195 deg des zones radioactives chez le rat expose a un haut flux de neutrons thermiques, importance du phosphore 32 dans l'irradiation interne consecutive

    Energy Technology Data Exchange (ETDEWEB)

    Chanteur, J; Pellerin, P [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1961-07-01

    Rats weighing 25 g were exposed for 5 mn to a flux of 6.10{sup 12} thermal neutrons/cm{sup 2}/s. Anatomical autoradiography at -195 deg. C has enabled the radioactive organs to be easily localised, to follow in course of time the decrease of radioactivity, and from it to deduce the probable nature of the numerous emitters in question. In particular, the phosphorus 32 has thus appeared to be one of those responsible for internal irradiation, general, on the one hand, by activating cellular phosphorus, local, on the other, by activating bony phosphates. Owing to this, an accidental irradiation by neutrons might have consequences that are both somatic (elective irradiation of the bone marrow) and genetic (activation of nucleic acids). The gamma spectrometry has confirmed the nature of certain other emitters. (author) [French] Des rats de 25 g ont ete exposes pendant 5 mn a un flux de 6.10{sup 12} neutrons thermiques/cm{sup 2}/s. L'autoradiographie anatomique a -195 deg. C a permis de localiser facilement les organes radioactifs, de suivre dans le temps la decroissance de la radioactivite, et d'en deduire la nature probable des nombreux emetteurs en cause. En particulier, le phosphore 32 est ainsi apparu comme l'un des responsables de l'irradiation interne, d'une part generale par activation du phosphore cellulaire, d'autre part locale par activation des phosphates osseux. Une irradiations accidentelle par neutrons aurait, de ce fait, des consequences a la fois somatiques (irradiation elective de la moelle osseuse) et genetiques (activation des acides nucleiques). La spectrometrie gamma a confirme la nature de certains autres emetteurs. (auteur)

  14. Dual Neutral Particle Beam Interrogation of Intermodal Shipping Containers for Special Nuclear Material

    Science.gov (United States)

    Keith, Rodney Lyman

    Intermodal shipping containers entering the United States provide an avenue to smuggle unsecured or stolen special nuclear material (SNM). The only direct method fielded to indicate the presence of SNM is by passive photon/neutron radiation detection. Active interrogation using neutral particle beams to induce fission in SNM is a method under consideration. One by-product of fission is the creation of fragments that undergo radioactive decay over a time period on the order of tens of seconds after the initial event. The "delayed" gamma-rays emitted from these fragments over this period are considered a hallmark for the presence of SNM. A fundamental model is developed using homogenized cargos with a SNM target embedded at the center and computationally interrogated using simultaneous neutron and photon beams. Findings from analysis of the delayed gamma emissions from these experiments are intended to mitigate the effects of poor quality information about the composition and disposition of suspect cargo before examination in an active interrogation portal.

  15. Evaluation of the neutron self-interrogation approach for assay of plutonium in high materials

    International Nuclear Information System (INIS)

    Russo, P.A.; Menlove, H.O.; Fife, K.W.; West, M.H.

    1987-01-01

    The pyrochemical scrap recovery processes, designed to extract impurities from plutonium metal and compounds, generate a variety of plutonium-laden residues consisting of high (α,n) matrices of varying chemical composition, and often containing grams to tens of grams of americium. For such materials, multiplication corrections based on real neutron coincidence count rate, R, and total neutron count rate, T, measurements cannot be applied because of the large, unknown, and variable (α,n) component in the total neutron emission rate. A study of the prototype self-interrogation assay method is in progress at the Los Alamos plutonium facility. In the self-interrogation approach, the assay signature R(IF)/T is a function of effective fissile plutonium content, where R(IF) is the induced fission component of the measured reals rate, and T is the measured, (α,n)-dominated totals rate. The present study includes a calibration effort using standards consisting of mixtures of PuO 2 and PuF 4 in a salt-strip matrix. The neutron measurements of the standards and the process materials have been performed at the Los Alamos Plutonium Facility. The precision and accuracy of the self-interrogation method applied to pyrochemical residues is examined in this study

  16. A Fiber Bragg Grating Interrogation System with Self-Adaption Threshold Peak Detection Algorithm.

    Science.gov (United States)

    Zhang, Weifang; Li, Yingwu; Jin, Bo; Ren, Feifei; Wang, Hongxun; Dai, Wei

    2018-04-08

    A Fiber Bragg Grating (FBG) interrogation system with a self-adaption threshold peak detection algorithm is proposed and experimentally demonstrated in this study. This system is composed of a field programmable gate array (FPGA) and advanced RISC machine (ARM) platform, tunable Fabry-Perot (F-P) filter and optical switch. To improve system resolution, the F-P filter was employed. As this filter is non-linear, this causes the shifting of central wavelengths with the deviation compensated by the parts of the circuit. Time-division multiplexing (TDM) of FBG sensors is achieved by an optical switch, with the system able to realize the combination of 256 FBG sensors. The wavelength scanning speed of 800 Hz can be achieved by a FPGA+ARM platform. In addition, a peak detection algorithm based on a self-adaption threshold is designed and the peak recognition rate is 100%. Experiments with different temperatures were conducted to demonstrate the effectiveness of the system. Four FBG sensors were examined in the thermal chamber without stress. When the temperature changed from 0 °C to 100 °C, the degree of linearity between central wavelengths and temperature was about 0.999 with the temperature sensitivity being 10 pm/°C. The static interrogation precision was able to reach 0.5 pm. Through the comparison of different peak detection algorithms and interrogation approaches, the system was verified to have an optimum comprehensive performance in terms of precision, capacity and speed.

  17. Facilitating biomedical researchers' interrogation of electronic health record data: Ideas from outside of biomedical informatics.

    Science.gov (United States)

    Hruby, Gregory W; Matsoukas, Konstantina; Cimino, James J; Weng, Chunhua

    2016-04-01

    Electronic health records (EHR) are a vital data resource for research uses, including cohort identification, phenotyping, pharmacovigilance, and public health surveillance. To realize the promise of EHR data for accelerating clinical research, it is imperative to enable efficient and autonomous EHR data interrogation by end users such as biomedical researchers. This paper surveys state-of-art approaches and key methodological considerations to this purpose. We adapted a previously published conceptual framework for interactive information retrieval, which defines three entities: user, channel, and source, by elaborating on channels for query formulation in the context of facilitating end users to interrogate EHR data. We show the current progress in biomedical informatics mainly lies in support for query execution and information modeling, primarily due to emphases on infrastructure development for data integration and data access via self-service query tools, but has neglected user support needed during iteratively query formulation processes, which can be costly and error-prone. In contrast, the information science literature has offered elaborate theories and methods for user modeling and query formulation support. The two bodies of literature are complementary, implying opportunities for cross-disciplinary idea exchange. On this basis, we outline the directions for future informatics research to improve our understanding of user needs and requirements for facilitating autonomous interrogation of EHR data by biomedical researchers. We suggest that cross-disciplinary translational research between biomedical informatics and information science can benefit our research in facilitating efficient data access in life sciences. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Fast Interrogation of Fiber Bragg Gratings with Electro-Optical Dual Optical Frequency Combs.

    Science.gov (United States)

    Posada-Roman, Julio E; Garcia-Souto, Jose A; Poiana, Dragos A; Acedo, Pablo

    2016-11-26

    Optical frequency combs (OFC) generated by electro-optic modulation of continuous-wave lasers provide broadband coherent sources with high power per line and independent control of line spacing and the number of lines. In addition to their application in spectroscopy, they offer flexible and optimized sources for the interrogation of other sensors based on wavelength change or wavelength filtering, such as fiber Bragg grating (FBG) sensors. In this paper, a dual-OFC FBG interrogation system based on a single laser and two optical-phase modulators is presented. This architecture allows for the configuration of multimode optical source parameters such as the number of modes and their position within the reflected spectrum of the FBG. A direct read-out is obtained by mapping the optical spectrum onto the radio-frequency spectrum output of the dual-comb. This interrogation scheme is proposed for measuring fast phenomena such as vibrations and ultrasounds. Results are presented for dual-comb operation under optimized control. The optical modes are mapped onto detectable tones that are multiples of 0.5 MHz around a center radiofrequency tone (40 MHz). Measurements of ultrasounds (40 kHz and 120 kHz) are demonstrated with this sensing system. Ultrasounds induce dynamic strain onto the fiber, which generates changes in the reflected Bragg wavelength and, hence, modulates the amplitude of the OFC modes within the reflected spectrum. The amplitude modulation of two counterphase tones is detected to obtain a differential measurement proportional to the ultrasound signal.

  19. The SVM Method for Fissile Mass Estimation through Passive Neutron Interrogation: Advances and Developments

    International Nuclear Information System (INIS)

    Dubi, C.; Shvili, Israel I.

    2014-01-01

    Fissile mass estimation through passive neutron interrogation is now one of the main techniques for NDT of fissile mass estimation, due to the relative transparency of neutron radiation to structural materials- making it extremely effective in poorly characterized or dirty samples . Passive neutron interrogation relies on the fact that the number of neutrons emitted (per time unit) due to spontaneous fissions from the sample is proportional to the mass of the detected sample. However, since the measurement is effected by additional neutron sources- mainly (D±n) reactions and induced fission chain in the tested sample, a naive estimation, assuming a linear correspondence between the mass of the detected sample and the average number of detections, is bound to give an over estimation of the mass. Since most passive interrogation facilities are based on 3He detectors, the origin of the neutron cannot be determined by analyzing the energy spectrum (as all neutrons arrive at the detector in more or less the same energy), and a mathematical 'filter' is used to evaluate the noise to source ratio in the detection signal. The basic idea behind the mathematical filter is to utilize the fact that the different neutron sources have different statistical attributes- in particular, both the source event rate and the distribution of the number of neutrons released in each event differs between the different sources. There for, by studying the higher moments of the neutron population, new information about the source to noise ration may be obtained

  20. [Research on symmetrical optical waveguide based surface plasmon resonance sensing with spectral interrogation].

    Science.gov (United States)

    Zhang, Yi-long; Liu, Le; Guo, Jun; Zhang, Peng-fei; Guo, Ji-hua; Ma, Hui; He, Yong-hong

    2015-02-01

    Surface plasmon resonance (SPR) sensors with spectral interrogation can adopt fiber to transmit light signals, thus leaving the sensing part separated, which is very convenient for miniaturization, remote-sensing and on-site analysis. Symmetrical optical waveguide (SOW) SPR has the same refractive index of the-two buffer media layers adjacent to the metal film, resulting in longer propagation distance, deeper penetration depth and better performance compared to conventional SPR In the present paper, we developed a symmetrical optical, waveguide (SOW) SPR sensor with wavelength interrogation. In the system, MgF2-Au-MgF2 film was used as SOW module for glucose sensing, and a fiber based light source and detection was used in the spectral interrogation. In the experiment, a refractive index resolution of 2.8 x 10(-7) RIU in fluid protocol was acquired. This technique provides advantages of high resolution and could have potential use in compact design, on-site analysis and remote sensing.

  1. TDM interrogation of intensity-modulated USFBGs network based on multichannel lasers.

    Science.gov (United States)

    Rohollahnejad, Jalal; Xia, Li; Cheng, Rui; Ran, Yanli; Rahubadde, Udaya; Zhou, Jiaao; Zhu, Lin

    2017-01-23

    We report a large-scale multi-channel fiber sensing network, where ultra-short FBGs (USFBGs) instead of conventional narrow-band ultra-weak FBGs are used as the sensors. In the time division multiplexing scheme of the network, each grating response is resolved as three adjacent discrete peaks. The central wavelengths of USFBGs are tracked with the differential detection, which is achieved by calculating the peak-to-peak ratio of two maximum peaks. Compared with previous large-scale hybrid multiplexing sensing networks (e.g., WDM/TDM) which typically have relatively low interrogation speed and very high complexity, the proposed system can achieve interrogation of all channel sensors through very fast and simple intensity measurements with a broad dynamic range. A proof-of-concept experiment with twenty USFBGs, at two wavelength channels, was performed and a fast static strain measurements were demonstrated, with a high average sensitivity of ~0.54dB/µƐ and wide dynamic range of over ~3000µƐ. The channel to channel switching time was 10ms and total network interrogation time was 50ms.

  2. Calibration of Cherenkov detectors for monoenergetic photon imaging in active interrogation applications

    Energy Technology Data Exchange (ETDEWEB)

    Rose, P.B., E-mail: prose6@gatech.edu; Erickson, A.S., E-mail: anna.erickson@me.gatech.edu

    2015-11-01

    Active interrogation of cargo containers using monoenergetic photons offers a rapid and low-dose approach to search for shielded special nuclear materials. Cherenkov detectors can be used for imaging of the cargo provided that gamma ray energies used in interrogation are well resolved, as the case in {sup 11}B(d,n-γ){sup 12}C reaction resulting in 4.4 MeV and 15.1 MeV photons. While an array of Cherenkov threshold detectors reduces low energy background from scatter while providing the ability of high contrast transmission imaging, thus confirming the presence of high-Z materials, these detectors require a special approach to energy calibration due to the lack of resolution. In this paper, we discuss the utility of Cherenkov detectors for active interrogation with monoenergetic photons as well as the results of computational and experimental studies of their energy calibration. The results of the studies with sources emitting monoenergetic photons as well as complex gamma ray spectrum sources, for example {sup 232}Th, show that calibration is possible as long as the energies of photons of interest are distinct.

  3. A wireless interrogation system exploiting narrowband acoustic resonator for remote physical quantity measurement

    International Nuclear Information System (INIS)

    Friedt, J.-M; Droit, C.; Martin, G.; Ballandras, S.

    2010-01-01

    Monitoring physical quantities using acoustic wave devices can be advantageously achieved using the wave characteristic dependence to various parametric perturbations (temperature, stress, and pressure). Surface acoustic wave (SAW) resonators are particularly well suited to such applications as their resonance frequency is directly influenced by these perturbations, modifying both the phase velocity and resonance conditions. Moreover, the intrinsic radio frequency (rf) nature of these devices makes them ideal for wireless applications, mainly exploiting antennas reciprocity and piezoelectric reversibility. In this paper, we present a wireless SAW sensor interrogation unit operating in the 434 MHz centered ISM band--selected as a tradeoff between antenna dimensions and electromagnetic wave penetration in dielectric media--based on the principles of a frequency sweep network analyzer. We particularly focus on the compliance with the ISM standard which reveals complicated by the need for switching from emission to reception modes similarly to radar operation. In this matter, we propose a fully digital rf synthesis chain to develop various interrogation strategies to overcome the corresponding difficulties and comply with the above-mentioned standard. We finally assess the reader interrogation range, accuracy, and dynamics.

  4. A wireless interrogation system exploiting narrowband acoustic resonator for remote physical quantity measurement

    Energy Technology Data Exchange (ETDEWEB)

    Friedt, J.-M [SENSeOR, 32 Avenue de l' Observatoire, 25044 Besancon (France); Droit, C.; Martin, G.; Ballandras, S. [Department of Time and Frequency, FEMTO-ST, 32 Avenue de l' Observatoire, 25044 Besancon (France)

    2010-01-15

    Monitoring physical quantities using acoustic wave devices can be advantageously achieved using the wave characteristic dependence to various parametric perturbations (temperature, stress, and pressure). Surface acoustic wave (SAW) resonators are particularly well suited to such applications as their resonance frequency is directly influenced by these perturbations, modifying both the phase velocity and resonance conditions. Moreover, the intrinsic radio frequency (rf) nature of these devices makes them ideal for wireless applications, mainly exploiting antennas reciprocity and piezoelectric reversibility. In this paper, we present a wireless SAW sensor interrogation unit operating in the 434 MHz centered ISM band--selected as a tradeoff between antenna dimensions and electromagnetic wave penetration in dielectric media--based on the principles of a frequency sweep network analyzer. We particularly focus on the compliance with the ISM standard which reveals complicated by the need for switching from emission to reception modes similarly to radar operation. In this matter, we propose a fully digital rf synthesis chain to develop various interrogation strategies to overcome the corresponding difficulties and comply with the above-mentioned standard. We finally assess the reader interrogation range, accuracy, and dynamics.

  5. Optical power-based interrogation of plasmonic tilted fiber Bragg grating biosensors

    Science.gov (United States)

    González-Vila, Á.; Lopez-Aldaba, A.; Kinet, D.; Mégret, P.; Lopez-Amo, M.; Caucheteur, C.

    2017-04-01

    Two interrogation techniques for plasmonic tilted fiber Bragg grating sensors are reported and experimentally tested. Typical interrogation methods are usually based on tracking the wavelength shift of the most sensitive cladding mode, but for biosensing applications, spectrometer-based methods can be replaced by more efficient solutions. The proposed techniques thus rely on the measurement of the induced changes in optical power. The first one consists of a properly polarized tunable laser source set to emit at the wavelength of the sensor most sensitive mode and an optical power meter to measure the transmitted response. For the second method, a uniform fiber Bragg grating is photo-inscribed beyond the sensor in such a way that its central wavelength matches the sensor most sensitive mode, acting as an optical filter. Using a LED source, light reflected backwards by this grating is partially attenuated when passing through the sensor due to plasmon wave excitation and the power changes are quantified once again with an optical power meter. A performance analysis of the techniques is carried out and they both result competitive interrogation solutions. The work thus focuses on the development of cost-effective alternatives for monitoring this kind of biosensors in practical situations.

  6. A Fiber Bragg Grating Interrogation System with Self-Adaption Threshold Peak Detection Algorithm

    Directory of Open Access Journals (Sweden)

    Weifang Zhang

    2018-04-01

    Full Text Available A Fiber Bragg Grating (FBG interrogation system with a self-adaption threshold peak detection algorithm is proposed and experimentally demonstrated in this study. This system is composed of a field programmable gate array (FPGA and advanced RISC machine (ARM platform, tunable Fabry–Perot (F–P filter and optical switch. To improve system resolution, the F–P filter was employed. As this filter is non-linear, this causes the shifting of central wavelengths with the deviation compensated by the parts of the circuit. Time-division multiplexing (TDM of FBG sensors is achieved by an optical switch, with the system able to realize the combination of 256 FBG sensors. The wavelength scanning speed of 800 Hz can be achieved by a FPGA+ARM platform. In addition, a peak detection algorithm based on a self-adaption threshold is designed and the peak recognition rate is 100%. Experiments with different temperatures were conducted to demonstrate the effectiveness of the system. Four FBG sensors were examined in the thermal chamber without stress. When the temperature changed from 0 °C to 100 °C, the degree of linearity between central wavelengths and temperature was about 0.999 with the temperature sensitivity being 10 pm/°C. The static interrogation precision was able to reach 0.5 pm. Through the comparison of different peak detection algorithms and interrogation approaches, the system was verified to have an optimum comprehensive performance in terms of precision, capacity and speed.

  7. Study of various processes for marking sediments with gold-198; Etude de divers procedes de marquages de sediments par l'or 198

    Energy Technology Data Exchange (ETDEWEB)

    Jeanneau, B [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-12-15

    The use of radioactive isotopes for the study of sediment deposits is based mainly on two methods: marking in the mass - a glass of an element which can be activated replaces the sediment; surface marking - a physico-chemical process is used to deposit a radio-element at the surface of the sediment. The second process is used in particular for sands when it is advantageous to have a large number of particles for statistical analysis. The aim of this work was to develop a rapid and simple method of marking which could be applied on the actual site of the experiment where equipment, may be limited. The method recommended for marking sand with gold-198 is a combination of the Petersen (treatment with tin chloride) and Campbell (treatment with silver) methods combined with prior treatments with nitric acid and caustic soda. Using this method it is possible to deposit 125 mg of gold per kilo of sediment with a yield of 95 per cent (i.e. 10 Ci/kg) using a hydrochloric acid solution containing gold. The problem of the solidity of the deposits, of their value and of their reproducibility is discussed from the point of view of the mineral constitution of the sand. (author) [French] L'utilisation d'isotopes radioactifs pour l'etude des deplacements sedimentaires fait, principalement appel a deux methodes: le marquage massique - un verre contenant un element activable remplace le sediment; le marquage superficiel - un traitement physico-chimique permet de deposer un radioelement a la surface du sediment. Le second procede est surtout employe pour les sables lorsqu'il est utile de disposer d'un grand nombre de grains pour des raisons statistiques. Le but de ce travail etait de mettre au point une methode simple et rapide de marquage pouvant etre appliquee sur le site meme de l'experience pour les utilisateurs disposant d'un equipement limite. Le procede preconise pour le marquage des sables par l'or 198 est une combinaison des methodes Petersen (traitement au chlorure d

  8. Performance of a remote interrogation system for the in-hospital evaluation of cardiac implantable electronic devices.

    Science.gov (United States)

    Mittal, Suneet; Younge, Kevin; King-Ellison, Kelly; Hammill, Eric; Stein, Kenneth

    2016-08-01

    Patients with a cardiac implantable electronic device (CIED) often need device interrogation in an in-hospital environment. A diagnosis-only, remote interrogation device and process for CIED interrogation was developed to address this situation. Here, we describe our initial clinical experience with this system. The LATITUDE Consult Communicator is a stand-alone interrogation-only device used to read the patient's implanted CIED. Once retrieved, the data are securely transmitted via an analog phone line to a central server. The clinician can request a review of the transmitted data at any time. Following FDA approval, we determined the usage and performance of the system. Communicators (n = 53) were installed in 42 hospital facilities. The most common location was in the emergency department (n = 32, 60 %). There were 509 discreet transmissions, which were categorized as follows: no arrhythmia episodes in the past 72 h and no out of range measurements (n = 174, 34 %); arrhythmia episodes in past 72 h but no out of range measurements (n = 170, 33 %); and further review recommended (n = 130, 26 %). (In 35 [7 %] instances, interrogation without analysis was requested.) The further review interrogations were then sub-divided into those of a non-urgent and urgent nature. Overall, only 53 (10 %) of the 509 transmissions were classified as urgent. Clinicians had access to full technical consultation in ≤15 min in 89 % of instances. Our data demonstrate the feasibility of a new diagnosis-only, remote interrogation device and remote evaluation process for the interrogation of CIEDs in an in-hospital environment.

  9. Processing Interrogative Sentence Mood at the Semantic-Syntactic Interface: An Electrophysiological Research in Chinese, German, and Polish

    Science.gov (United States)

    Kao, Chung-Shan; Dietrich, Rainer; Sommer, Werner

    2010-01-01

    Background Languages differ in the marking of the sentence mood of a polar interrogative (yes/no question). For instance, the interrogative mood is marked at the beginning of the surface structure in Polish, whereas the marker appears at the end in Chinese. In order to generate the corresponding sentence frame, the syntactic specification of the interrogative mood is early in Polish and late in Chinese. In this respect, German belongs to an interesting intermediate class. The yes/no question is expressed by a shift of the finite verb from its final position in the underlying structure into the utterance initial position, a move affecting, hence, both the sentence's final and the sentence's initial constituents. The present study aimed to investigate whether during generation of the semantic structure of a polar interrogative, i.e., the processing preceding the grammatical formulation, the interrogative mood is encoded according to its position in the syntactic structure at distinctive time points in Chinese, German, and Polish. Methodology/Principal Findings In a two-choice go/nogo experimental design, native speakers of the three languages responded to pictures by pressing buttons and producing utterances in their native language while their brain potentials were recorded. The emergence and latency of lateralized readiness potentials (LRP) in nogo conditions, in which speakers asked a yes/no question, should indicate the time point of processing the interrogative mood. The results revealed that Chinese, German, and Polish native speakers did not differ from each other in the electrophysiological indicator. Conclusions/Significance The findings suggest that the semantic encoding of the interrogative mood is temporally consistent across languages despite its disparate syntactic specification. The consistent encoding may be ascribed to economic processing of interrogative moods at various sentential positions of the syntactic structures in languages or, more

  10. FBG Interrogation Method with High Resolution and Response Speed Based on a Reflective-Matched FBG Scheme

    Science.gov (United States)

    Cui, Jiwen; Hu, Yang; Feng, Kunpeng; Li, Junying; Tan, Jiubin

    2015-01-01

    In this paper, a high resolution and response speed interrogation method based on a reflective-matched Fiber Bragg Grating (FBG) scheme is investigated in detail. The nonlinear problem of the reflective-matched FBG sensing interrogation scheme is solved by establishing and optimizing the mathematical model. A mechanical adjustment to optimize the interrogation method by tuning the central wavelength of the reference FBG to improve the stability and anti-temperature perturbation performance is investigated. To satisfy the measurement requirements of optical and electric signal processing, a well- designed acquisition circuit board is prepared, and experiments on the performance of the interrogation method are carried out. The experimental results indicate that the optical power resolution of the acquisition circuit border is better than 8 pW, and the stability of the interrogation method with the mechanical adjustment can reach 0.06%. Moreover, the nonlinearity of the interrogation method is 3.3% in the measurable range of 60 pm; the influence of temperature is significantly reduced to 9.5%; the wavelength resolution and response speed can achieve values of 0.3 pm and 500 kHz, respectively. PMID:26184195

  11. FBG Interrogation Method with High Resolution and Response Speed Based on a Reflective-Matched FBG Scheme.

    Science.gov (United States)

    Cui, Jiwen; Hu, Yang; Feng, Kunpeng; Li, Junying; Tan, Jiubin

    2015-07-08

    In this paper, a high resolution and response speed interrogation method based on a reflective-matched Fiber Bragg Grating (FBG) scheme is investigated in detail. The nonlinear problem of the reflective-matched FBG sensing interrogation scheme is solved by establishing and optimizing the mathematical model. A mechanical adjustment to optimize the interrogation method by tuning the central wavelength of the reference FBG to improve the stability and anti-temperature perturbation performance is investigated. To satisfy the measurement requirements of optical and electric signal processing, a well- designed acquisition circuit board is prepared, and experiments on the performance of the interrogation method are carried out. The experimental results indicate that the optical power resolution of the acquisition circuit border is better than 8 pW, and the stability of the interrogation method with the mechanical adjustment can reach 0.06%. Moreover, the nonlinearity of the interrogation method is 3.3% in the measurable range of 60 pm; the influence of temperature is significantly reduced to 9.5%; the wavelength resolution and response speed can achieve values of 0.3 pm and 500 kHz, respectively.

  12. Increasing dynamic range of a fibre Bragg grating edge-filtering interrogator with a proportional control loop

    International Nuclear Information System (INIS)

    Stan, Nikola; Bailey, D C; Chadderdon, S L; Selfridge, R H; Schultz, S M; Webb, S; Zikry, M; Peters, K J

    2014-01-01

    We present a fibre Bragg grating (FBG) interrogator that uses a microcontroller board and a tunable optical filter in a proportional control loop to increase dynamic range and achieve high strain sensitivity. It is an edge-filtering interrogator with added proportional control loop that locks the operating wavelength to the mid-reflection point on the FBG spectrum. The interrogator separates low-frequency (LF) components of strain and measures them with extended dynamic range, while at the same time measuring high-frequency (HF) strain without loss in strain sensitivity. In this paper, we describe the implementation of the interrogator and analyse the characteristics of individual components, such as the speed and voltage resolution of the microcontroller and the tunable optical filter. We measure the performance of the proportional control loop at frequencies up to 1 kHz and characterize the system using control theory. We illustrate the limitation of the conventional interrogator to measure strains greater than 40 μϵ and demonstrate successful application of the proposed interrogator for simultaneous measurement of 450 μϵ LF strain at 50 Hz superimposed with 32 kHz HF strain. (paper)

  13. Childhood Pars Planitis; Clinical Features and Outcomes

    Directory of Open Access Journals (Sweden)

    Homayoon Nikkhah

    2011-01-01

    Full Text Available Purpose: To evaluate the demographic and clinical features of childhood pars planitis, and to determine the therapeutic and visual outcomes of the disease. Methods: Medical records of pediatric patients (less than 16 years of age at diagnosis with pars planitis and at least 6 months of follow-up who were referred to Labbafinejad Medical Center, Tehran, Iran over a 22 year period were reviewed. Results: Overall, 117 eyes of 61 patients including 51 (83.6% male subjects were included. Mean age at the time of diagnosis was 7.8΁3.2 (range, 3-16 years. Mean best corrected visual acuity (BCVA was 0.88΁0.76 logMAR at presentation which improved to 0.39΁0.51 logMAR at final visit (P<0.001. Endotheliitis was present in 23 (19.6% eyes and was significantly more prevalent in subjects younger than 9 years (P=0.025. Cataract formation (41.9% and cystoid macular edema (19.7% were the most prevalent complications. Univariate regression analysis showed that better baseline visual acuity (OR=0.38, 95%CI 0.21-0.70, P=0.002, age older than 5 years at disease onset (OR=0.36, 95%CI 0.14-0.9, P=0.029, absence of endotheliitis (OR=0.39, 95%CI 0.15-0.99, P=0.047 and female gender (OR=3.77, 95%CI 1.03-13.93, P=0.046 were significantly associated with final BCVA of 20/40 or better. Conclusion: Childhood pars planitis was much more common among male subjects. Endotheliitis may be a sign of inflammation spillover and is more prevalent in younger patients. Visual prognosis is favorable in most patients with appropriate treatment.

  14. Solidification of Radioactive Waste Solutions; Solidification des Effluents Radioactifs; 041e 0422 0412 0415 0420 0416 0414 0415 041d 0418 0415 0420 0410 0414 0418 041e 0410 041a 0422 0418 0412 041d 042b 0425 0421 0411 0420 041e 0421 041d 042b 0425 0420 0410 0421 0422 0412 041e 0420 041e 0412 ; Solidificacion de Efluentes Radiactivos

    Energy Technology Data Exchange (ETDEWEB)

    Brezhneva, N. E.; Golovanov, Ju. N.; Oziraner, S. N.; Eremin, A. A.; Rozanova, V. N.

    1963-02-15

    This paper sets out the results of experimental development of a method for the solidifaction of radioactive waste solutions, based on the drying and vitrification of precipitates of iron-hydroxide obtained by settling from radioactive solutions. The solidification system is based on the principle of maximum reduction of the waste off-gases after removal of the aerosols and volatile radioactive components. The authors established optimum conditions to obtain a chemically stable glass and succeeded in lowering the temperature for the melting of the glass by modifying the fluxes added. An appreciable drop in the chemical stability of the glass was noted when it was stored for a long time at temperatures above 300 Degree-Sign - 350 Degree-Sign C. The authors studied the leachability of radiocaesium from the glass. They also investigated the volatility of radiocaesium and radio ruthenium in the course of drying and melting and showed that in an atmosphere of carbonic acid gas the volatility of ruthenium completely disappears. Hie volatility of radiocaesium in appreciable quantities becomes noticeable at temperatures above 700 Degree-Sign C and increases as the temperature rises. It is shown that radiocaesium condenses in the drainage tubes at temperatures below 400 Degree-Sign C and is easily washed off by weak solutions of nitric acid and water. Calculations of the heat release from radioactive glass show that the radius of globular glass castings from high-activity materials (10 c/g) must not exceed 25 cm. The paper includes the flowsheet for a process for the drying and vitrification of radioactive sludge by means of a gas- and heat-remover, together with details of the apparatus required. (author) [French] Les auteurs exposent les resultats des recherches qu'ils ont faites, dans leur laboratoire, pour mettre au point une methode de solidification des effluents radioactifs, fondee sur la dessiccation et la vitrification de l'hydroxyde de fer, obtenu par

  15. Origin, Nature, Disposal and Control of Radioactive Wastes Arising from the Use of Radioisotopes; Origine, Nature, Elimination et Controle des Dechets Radioactifs Decoulant de l'Emploi des Radioisotopes; 041f 0420 041e 0414 ; Origen, Naturaleza, Evacuacion y Control de los Desechos Radiactivos Producidos en la Utilizacion de Radioisotopos

    Energy Technology Data Exchange (ETDEWEB)

    Kenny, A. W. [Ministry of Housing and Local Government (United Kingdom)

    1960-07-01

    The paper describes the different types of radioactive waste arising from industrial, medical and scientific uses of radioisotopes. An outline is given of methods used for waste disposal, depending on the content of radioactivity. (author) [French] L'auteur decrit les differents types de dechets radioactifs decoulant de l'utilisation de radioisotopes dans l'industrie, en medecine et dans la science. Il donne un apercu des methodes employees pour l'elimination des dechets selon leur teneur en elements radioactifs. (author) [Spanish] En la memoria se describen los diferentes tipos de desechos radiactivos producidos por la utilizacion industrial, medica y cientifica de los radioisotopos y se hace una exposicion de los metodos empleados para la evacuacion de desechos segun su contenido radiactivo. (author) [Russian] V doklade daetsja opisanie razlichnyh tipov radioaktivnyh othodov, voznikajushhih v rezul'tate promyshlennogo, medicinskogo i nauchnogo ispol'zovanija radioizotopov. Osobo razbirajutsja metody, ispol'zuemye dlja udalenija radioaktivnyh othodov v zavisimosti ot ih radioaktivnosti. (author)

  16. Usefulness of the decay rate in the management of radioactive waste stocks; De l'interet de la decroissance pour la gestion des dechets radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    Rodier, J; Cohendy, G [Commissariat a l' Energie Atomique, Chusclan (France). Centre de Production de Plutonium de Marcoule

    1969-07-01

    It became apparent, during first few years operation of the Marcoule Centre, that it was very useful to exploit the natural decay rate of the radioactive element contaminating the waste. The storage of this waste under the best possible conditions in each case, was first of all favorable for the radiological safety point of view; it led, furthermore, to a marked reduction in the cost price since it made it possible to avoid employing protection means which would have proved to be excessively outsize after a few years. Finally, even when the half-life of the radioelements involved seemed to annul any possible advantages of this method, the temporary storage made it possible to develop treatment processes which were unknown at the time. The overall result of this policy is that at the present time over 98 per cent of the solid waste produced by the Marcoule Centre has been processed in such a way that it can, at any moment, be discharged from the site without difficulty. (authors) [French] Des les premieres annees de fonctionnement du Centre de Marcoule, il est apparu qu'il etait extremement benefique de mettre a profit la decroissance naturelle des elements radioactifs contaminant les dechets. Le stockage de ces dechets dans des conditions appropriees a chaque cas d'espece a tout d'abord ete favorable a la surete radiologique; en outre, il a abouti a une reduction sensible des prix de revient, du fait qu'il a evite de mettre en oeuvre des moyens de protection qui se seraient reveles surdimensionnes au bout de quelques annees. Enfin, meme lorsque la periode des radioelements en cause semblait enlever tout interet a cette methode, le stockage d'attente a permis de mettre au point des procedes de traitement inconnus a l'epoque. Le resultat global de cette politique est que, actuellement, plus de 98 pour cent des dechets solides produits depuis l'origine du Centre de Marcoule ont ete conditionnes de telle sorte qu'ils peuvent, a tout moment, etre evacues hors du Site

  17. Storage and Disposal of Solid Radioactive Waste; Stockage et Evacuation des Dechets Radioactifs Solides; 0425 0420 0414 ; Almacenamiento y Evacuacion de Desechos Radiactivos Solidos

    Energy Technology Data Exchange (ETDEWEB)

    Pomarola, J. [Chef du Bureau Technique, Service de Controle des Radiations et de Genie Radioactif, Commissariat a l' Energie Atomique, Saclay (France)

    1960-07-01

    This paper deals with solutions for the problem of final disposal of solid radioactive waste. I. It is first essential to organize a proper system of temporary storage. II. Final Storage In order to organize final storage, it is necessary to fix, according to the activity and form of the waste, the site and the modes of transport to be used within and outside the nuclear centre. The choice of solutions follows from the foregoing essentials. The paper then considers, in turn, final storage, on the ground, in the sub-soil and in the sea. Economic considerations are an important factor in determining the choice of solution. (author) [French] La presente communication a pour objet les solutions envisagees pour une destination finale des dechets radioactifs solides. I - Il est tout d'abord necessaire de prevoir un stockage provisoire organise. II - Stockage definitif: La realisation d'un stockage definitif rend necessaire, en fonction de l'activite et du conditionnement des dechets, la definition: - du site et des modes de transports envisages a l'interieur et a l'exterieur des Centres Nucleaires. Le choix des solutions decoule des imperatifs ci-dessus et on examine successivement le stockage definitif: - sur le sol, - dans le sous-sol, - en mer. Les considerations d'ordre economique constituent un facteur important dans le choix de la solution. (author) [Spanish] El autor de la memoria estudia las diferentes soluciones previstas para la evacuacion definitiva de los desechos radiactivos solidos. I - Antes que nada hay que preparar un almacenamiento provisional organizado. II - Evacuacion definitiva : Para organizar la evacuacion definitiva es necesario definir antes, en funcion de la actividad y acondicionamiento de los desechos: - el emplazamiento y la forma de transporte que se piensa utilizar en el interior y en el exterior de los centros nucleares. La eleccion de las diversas soluciones depende de las dos condiciones mencionadas; el autor examina sucesivamente la

  18. Interrogating CGPA

    Directory of Open Access Journals (Sweden)

    Vivek Kumar Jain

    2014-12-01

    Full Text Available The system of teaching and assessment in the higher education in India is passing through a phase of transition. Many of the universities in India have adopted the semester system with credit- and grade-based evaluation of students. These systems are functionally different from the annual system of teaching and evaluation based on marks and percentage. The grade-based system of evaluation is recommended for its virtues and is accepted as a progressive step toward reforms in the higher education system. However, a critical evaluation of the new system vis-à-vis the older one is necessary. The objective of this article is to focus on some of the issues associated with the calculation of grade point average (in absolute grading, to focus on the anomalies created thereby in conversion of grade point average to percentage, and to suggest alternatives to minimize the arbitrariness so that the examinee is not penalized. The present work illustrates the problems inherent in the grading system using examples from Indian universities. Subsequently, the probable reasons for the problems are discussed. Finally, simple alternative measures are suggested to overcome the shortcomings of the grading system.

  19. Interrogating Diaspora

    DEFF Research Database (Denmark)

    Pærregaard, Karsten

    2010-01-01

    Kapitlet diskuterer generelt de analytiske muligheder og begrænsninger for brugen af diasporabegrebet og undersøger, hvordan det kan anvendes på et studie af peruansk migration med særlig henblik på migrationens politiske, solidariske og klassemæssige aspekter....

  20. Soil contamination. part 1. changes in the humidity of non saturated soils after reject in a limited space. part 2. movements of radioactive ions in non saturated soils after reject in a limited space; Contamination des sols (1. partie). Evolution de l'humidite dans les sols non satures apres rejets sur une surface limitee. (2. partie). Comportement des ions radioactifs dans les sols non satures apres rejets d'eau sur une surface limitee

    Energy Technology Data Exchange (ETDEWEB)

    Rancon, D [Commissariat a l' Energie Atomique, Cadarache (France). Centre d' Etudes Nucleaires

    1972-07-01

    upon the counting rate of radioactivity. This method which have allowed to get various results about {sup 131}I and {sup 85}Sr can be generalized to other radioisotopes and other soils. They are applicable to radiological safety of sites studies : Testing storage plants, estimate of accidents hazards and protection of subterranean waters. (author) [French] II est important, dans les etudes de surete radiologique de sites, de connaitre les mouvements d'eau dans les terrains non satures surmontant la nappe aquifere, cette tranche de terrain aere pouvant servir de protection contre la contamination de la nappe. L'utilisation d'humidimetres a neutrons a permis de construire graphiquement les coupes des etats hydriques du terrain et les evolutions dans le temps du volume du sol mouille a partir d'un rejet affectant une superficie restreinte. On mesure aussi les gradients d'humidite, les cinetiques d'assechement, la capacite de retention du sol et la teneur en eau gravifique suspendue en en equilibre avec la charge d'eau. L'etat hydrique initial influence la vitesse d'infiltration et non la vitesse d'avancement du front d'humectation, on peut donc calculer la quantite d'eau accumulable par le terrain. Apres l'arret du rejet, le volume de sol mouille evolue jusqu'a un etat d'equilibre limite par le front d'humectation, les redistributions d'humidite s'effectuant seulement au sein de ce volume; ainsi, en cas de rejet de liquide radioactif, les ions contaminants resteront confines dans un volume mesurable limite par le front d'humectation. Partie 2. Pour faire suite au rapport sur les mouvements d'eau dans les sols non satures apres rejet sur une surface limitee - CEA R 3635 (1) - on etudie les mouvements des ions radioactifs dans ces sols en utilisant un anion et un cathion caracteristiques: l'iode 131 et le strontium 85. La methode est basee sur la mesure simultanee des fronts d'humidite et d'activite au moyen d'humidimetre a neutrons et d'une sonde d'activite specialement

  1. Accouchement par forceps: indications et pronostic materno-foetal ...

    African Journals Online (AJOL)

    L'accouchement par voie basse, peut être parfois compromis par des facteurs maternels, foetaux ou materno-foetaux nécessitant des moyens thérapeutiques comme le forceps pour achever l'accouchement par voie naturelle. Le forceps, une méthode qui n'est pas sans risque pour la mère et le nouveau-né. Nous avons ...

  2. Achievable Performance and Effective Interrogator Design for SAW RFID Sensor Tags

    Science.gov (United States)

    Barton Richard J.

    2012-01-01

    For many NASA missions, remote sensing is a critical application that supports activities such as environmental monitoring, planetary science, structural shape and health monitoring, non-destructive evaluation, etc. The utility of the remote sensing devices themselves is greatly increased if they are passive V that is, they do not require any on-board power supply such as batteries V and if they can be identified uniquely during the sensor interrogation process. Additional passive sensor characteristics that enable greater utilization in space applications are small size and weight, long read ranges with low interrogator power, ruggedness, and operability in extreme environments (vacuum, extreme high/low temperature, high radiation, etc.) In this paper, we consider one very promising passive sensor technology, called surface acoustic wave (SAW) radio-frequency identification (RFID), that satisfies all of these criteria. In general, RFID is a method of identifying items using radio waves to interrogate tags encoded with a unique identifier that are affixed to the items of interest. In the case of passive tags, only the interrogator, which transmits power to the tags in the form of radio-frequency electromagnetic radiation, requires access to a power supply. Passive RFID technologies are used today in many applications, including asset tracking and management, security and access control, and remote sensing. To date, most of the development and application in RFID technology has focused on either asset/inventory tracking and control or security and access control because these are the largest commercial application areas. Recently however, there has been growing interest in using passive RFID technology for remote sensing applications, and SAW devices are at the forefront of RFID sensing technology development. Although SAW RFID tags have great potential for use in numerous space-based remote sensing applications, the limited collision resolution capability of

  3. Intrathecal Pump Exposure to Electromagnetic Interference: A Report of Device Interrogation following Multiple ECT Sessions.

    Science.gov (United States)

    Bicket, Mark C; Hanna, George M

    2016-02-01

    Intrathecal drug delivery systems represent an increasingly common treatment modality for patients with a variety of conditions, including chronic pain and spasticity. Pumps rely on electronic programming to properly control and administer highly concentrated medications. Electromagnetic interference (EMI) is a known exposure that may cause a potential patient safety issue stemming from direct patient injury, pump damage, or changes to pump operation or flow rate. The objective of our case report was to describe an approach to evaluating a patient with a pump prior to and following exposure to EMI from electroconvulsive therapy (ECT), as well as to document findings from device interrogations associated with this event. Case report. Academic university-based pain management center. We present the case of a patient with an intrathecal pump who underwent multiple exposures to EMI in the form of 42 ECT sessions. Interrogation of the intrathecal drug delivery system revealed no safety issues following ECT sessions. At no time were error messages, unintentional changes in event logs, unintentional changes in pump settings, or evidence of pump stall or over-infusion noted. Communication with multiple entities (patient, family, consulting physicians, and device manufacturer) and maintaining vigilance through device interrogation both before and after EMI exposure are appropriate safeguards to mitigate the risk and detect potential adverse events of EMI with intrathecal drug delivery systems. Given the infrequent reports of device exposure to ECT, best practices may be derived from experience with EMI exposure from magnetic resonance imaging (MRI). Although routine EMI exposure to intrathecal drug delivery systems should be avoided, we describe one patient with repeated exposure to ECT without apparent complication.

  4. Mechanism of duplex DNA destabilization by RNA-guided Cas9 nuclease during target interrogation.

    Science.gov (United States)

    Mekler, Vladimir; Minakhin, Leonid; Severinov, Konstantin

    2017-05-23

    The prokaryotic clustered regularly interspaced short palindromic repeats (CRISPR)-associated 9 (Cas9) endonuclease cleaves double-stranded DNA sequences specified by guide RNA molecules and flanked by a protospacer adjacent motif (PAM) and is widely used for genome editing in various organisms. The RNA-programmed Cas9 locates the target site by scanning genomic DNA. We sought to elucidate the mechanism of initial DNA interrogation steps that precede the pairing of target DNA with guide RNA. Using fluorometric and biochemical assays, we studied Cas9/guide RNA complexes with model DNA substrates that mimicked early intermediates on the pathway to the final Cas9/guide RNA-DNA complex. The results show that Cas9/guide RNA binding to PAM favors separation of a few PAM-proximal protospacer base pairs allowing initial target interrogation by guide RNA. The duplex destabilization is mediated, in part, by Cas9/guide RNA affinity for unpaired segments of nontarget strand DNA close to PAM. Furthermore, our data indicate that the entry of double-stranded DNA beyond a short threshold distance from PAM into the Cas9/single-guide RNA (sgRNA) interior is hindered. We suggest that the interactions unfavorable for duplex DNA binding promote DNA bending in the PAM-proximal region during early steps of Cas9/guide RNA-DNA complex formation, thus additionally destabilizing the protospacer duplex. The mechanism that emerges from our analysis explains how the Cas9/sgRNA complex is able to locate the correct target sequence efficiently while interrogating numerous nontarget sequences associated with correct PAMs.

  5. A Kinematically Beamed, Low Energy Pulsed Neutron Source for Active Interrogation

    International Nuclear Information System (INIS)

    Dietrich, D.; Hagmann, C.; Kerr, P.; Nakae, L.; Rowland, M.; Snyderman, N.; Stoeffl, W.; Hamm, R.

    2004-01-01

    We are developing a new active interrogation system based on a kinematically focused low energy neutron beam. The key idea is that one of the defining characteristics of SNM (Special Nuclear Materials) is the ability for low energy or thermal neutrons to induce fission. Thus by using low energy neutrons for the interrogation source we can accomplish three goals, (1) Energy discrimination allows us to measure the prompt fast fission neutrons produced while the interrogation beam is on; (2) Neutrons with an energy of approximately 60 to 100 keV do not fission 238U and Thorium, but penetrate bulk material nearly as far as high energy neutrons do and (3) below about 100keV neutrons lose their energy by kinematical collisions rather than via the nuclear (n,2n) or (n,n') processes thus further simplifying the prompt neutron induced background. 60 keV neutrons create a low radiation dose and readily thermal capture in normal materials, thus providing a clean spectroscopic signature of the intervening materials. The kinematically beamed source also eliminates the need for heavy backward and sideway neutron shielding. We have designed and built a very compact pulsed neutron source, based on an RFQ proton accelerator and a lithium target. We are developing fast neutron detectors that are nearly insensitive to the ever-present thermal neutron and neutron capture induced gamma ray background. The detection of only a few high energy fission neutrons in time correlation with the linac pulse will be a clear indication of the presence of SNM

  6. Assessment of effectiveness of geologic isolation systems: the feasibility of computer interrogation of experts for WISAP

    Energy Technology Data Exchange (ETDEWEB)

    Wight, L.H.

    1980-05-01

    Simulation of the response of a waste repository to events that could initiate a fault tree to breach and failure is currently a keystone to the Battelle Waste Isolation Safety Assessment Program (WISAP). The repository simulation, which is part of the Disruptive Event Analysis Task, models the repository for its entire design life, one million years. This is clearly a challenging calculation, requiring input unlike any other response analysis by virtue of the long design life of the facility. What technology will provide design criteria for a million year design life. Answers to questions like this can, to some extent, be based on data, but always require some subjective judgments. The subjectivity, which is sometimes driven by inadequate or incomplete data or by a lack of understanding of the physical process, is therefore a crucial ingredient in an analysis of initiating events. Because of the variety of possible initiating events (glaciation, man-caused disruption, volcanism, etc.), many expert opinions will be solicited as input. The complexity of the simulation, the variety of experts involved, and the volume of applicable data all suggest that there may be a more direct, economical method to solicit the expert opinion. This report addresses the feasibility of such a system. Background information is presented that demonstrates the advantages of a computer interrogation system over conventional interrogation and assessment techniques. In the subsequent three sections the three elements - structure and decomposition, scaling, and synthesis - that are basic to any interrogation and assessment technique are reviewed. The interrelationship are schematically illustrated between these three fundamental elements and, therefore, serves as a useful guide to these three sections. Each of these three sections begins with a recommended approach to the particular element and ends with an illustration of representative dialogue.

  7. Assessment of effectiveness of geologic isolation systems: the feasibility of computer interrogation of experts for WISAP

    International Nuclear Information System (INIS)

    Wight, L.H.

    1980-05-01

    Simulation of the response of a waste repository to events that could initiate a fault tree to breach and failure is currently a keystone to the Battelle Waste Isolation Safety Assessment Program (WISAP). The repository simulation, which is part of the Disruptive Event Analysis Task, models the repository for its entire design life, one million years. This is clearly a challenging calculation, requiring input unlike any other response analysis by virtue of the long design life of the facility. What technology will provide design criteria for a million year design life. Answers to questions like this can, to some extent, be based on data, but always require some subjective judgments. The subjectivity, which is sometimes driven by inadequate or incomplete data or by a lack of understanding of the physical process, is therefore a crucial ingredient in an analysis of initiating events. Because of the variety of possible initiating events (glaciation, man-caused disruption, volcanism, etc.), many expert opinions will be solicited as input. The complexity of the simulation, the variety of experts involved, and the volume of applicable data all suggest that there may be a more direct, economical method to solicit the expert opinion. This report addresses the feasibility of such a system. Background information is presented that demonstrates the advantages of a computer interrogation system over conventional interrogation and assessment techniques. In the subsequent three sections the three elements - structure and decomposition, scaling, and synthesis - that are basic to any interrogation and assessment technique are reviewed. The interrelationship are schematically illustrated between these three fundamental elements and, therefore, serves as a useful guide to these three sections. Each of these three sections begins with a recommended approach to the particular element and ends with an illustration of representative dialogue

  8. Fast Interrogation of Fiber Bragg Gratings with Electro-Optical Dual Optical Frequency Combs

    Directory of Open Access Journals (Sweden)

    Julio E. Posada-Roman

    2016-11-01

    Full Text Available Optical frequency combs (OFC generated by electro-optic modulation of continuous-wave lasers provide broadband coherent sources with high power per line and independent control of line spacing and the number of lines. In addition to their application in spectroscopy, they offer flexible and optimized sources for the interrogation of other sensors based on wavelength change or wavelength filtering, such as fiber Bragg grating (FBG sensors. In this paper, a dual-OFC FBG interrogation system based on a single laser and two optical-phase modulators is presented. This architecture allows for the configuration of multimode optical source parameters such as the number of modes and their position within the reflected spectrum of the FBG. A direct read-out is obtained by mapping the optical spectrum onto the radio-frequency spectrum output of the dual-comb. This interrogation scheme is proposed for measuring fast phenomena such as vibrations and ultrasounds. Results are presented for dual-comb operation under optimized control. The optical modes are mapped onto detectable tones that are multiples of 0.5 MHz around a center radiofrequency tone (40 MHz. Measurements of ultrasounds (40 kHz and 120 kHz are demonstrated with this sensing system. Ultrasounds induce dynamic strain onto the fiber, which generates changes in the reflected Bragg wavelength and, hence, modulates the amplitude of the OFC modes within the reflected spectrum. The amplitude modulation of two counterphase tones is detected to obtain a differential measurement proportional to the ultrasound signal.

  9. X-ray and neutron interrogation of air cargo for mobile applications

    Energy Technology Data Exchange (ETDEWEB)

    Van Liew, Seth

    2015-06-01

    A system for scanning break-bulk cargo for mobile applications is presented. This combines a 140 kV multi-view, multi-energy X-ray system with 2.5 MeV neutrons. The system uses dual energy X-ray radiography with neutron radiography. The X-ray and neutron systems were designed to be collocated in a mobile environment. Various materials were interrogated with the intent of distinguishing threat materials such as explosives from similar benign materials. In particular, the identification of threats and bengins with nearly identical effective atomic numbers has been demonstrated.

  10. Enhanced sensitivity of surface plasmon resonance phase-interrogation biosensor by using oblique deposited silver nanorods.

    Science.gov (United States)

    Chung, Hung-Yi; Chen, Chih-Chia; Wu, Pin Chieh; Tseng, Ming Lun; Lin, Wen-Chi; Chen, Chih-Wei; Chiang, Hai-Pang

    2014-01-01

    Sensitivity of surface plasmon resonance phase-interrogation biosensor is demonstrated to be enhanced by oblique deposited silver nanorods. Silver nanorods are thermally deposited on silver nanothin film by oblique angle deposition (OAD). The length of the nanorods can be tuned by controlling the deposition parameters of thermal deposition. By measuring the phase difference between the p and s waves of surface plasmon resonance heterodyne interferometer with different wavelength of incident light, we have demonstrated that maximum sensitivity of glucose detection down to 7.1 × 10(-8) refractive index units could be achieved with optimal deposition parameters of silver nanorods.

  11. Systematic Functional Interrogation of Rare Cancer Variants Identifies Oncogenic Alleles | Office of Cancer Genomics

    Science.gov (United States)

    Cancer genome characterization efforts now provide an initial view of the somatic alterations in primary tumors. However, most point mutations occur at low frequency, and the function of these alleles remains undefined. We have developed a scalable systematic approach to interrogate the function of cancer-associated gene variants. We subjected 474 mutant alleles curated from 5,338 tumors to pooled in vivo tumor formation assays and gene expression profiling. We identified 12 transforming alleles, including two in genes (PIK3CB, POT1) that have not been shown to be tumorigenic.

  12. Methods and systems for Raman and optical cross-interrogation in flow-through silicon membranes

    Science.gov (United States)

    Bond, Tiziana C.; Letant, Sonia E.

    2014-09-09

    Cross-interrogating photonic detection systems and methods are shown. A flow through photonic crystal membrane with a surface enhanced Raman scattering (SERS) substrate is provided with pores which are distributed along multiple regions. The pores of one region have walls to which a first type of target specific anchor can be attached, while pores of another region have walls to which a second type of target specific anchor can be attached. An optical arrangement out-of-plane to the SERS substrate is also provided for enhanced sensitivity and identification of target organisms.

  13. X-ray and neutron interrogation of air cargo for mobile applications

    International Nuclear Information System (INIS)

    Van Liew, Seth

    2015-01-01

    A system for scanning break-bulk cargo for mobile applications is presented. This combines a 140 kV multi-view, multi-energy X-ray system with 2.5 MeV neutrons. The system uses dual energy X-ray radiography with neutron radiography. The X-ray and neutron systems were designed to be collocated in a mobile environment. Various materials were interrogated with the intent of distinguishing threat materials such as explosives from similar benign materials. In particular, the identification of threats and bengins with nearly identical effective atomic numbers has been demonstrated

  14. The study of some thiazinic and indaminic dye syntheses induced by ionising radiation; Etude de quelques syntheses de colorants thianziniques et indaminiques amorcees par les rayonnements ionisants

    Energy Technology Data Exchange (ETDEWEB)

    Balestic, S [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-03-15

    With a view to finding some radiochemical reactions applicable on an industrial scale for evaluating the radioactive waste from nuclear reactors, a systematic study was made of the radiochemical synthesis of thiazinic dyes such as methylene blue and Lauths' violet, on which the first tests were carried out in 1954. The first part of the study concerned the identification and the dosage, during radiolysis, of dyes by means of their absorption spectra after separation from the reaction medium by adsorption chromatography or ion-exchange; other radiolysis products such as ammonium chloride and hydrogen peroxide were also identified. During a later stage by systematically varying the physico-chemical parameters it was possible to determine the most favourable conditions for radio-synthesis; the maximum radiochemical yields obtained had the following values: G (Lauths' violet) 1,65; G (Methylene blue) = 1,75. Furthermore, the study of the influence of variously substituted aminated products on the radiochemical yield showed the possibility of synthesising Bindsehedlers green and Wursters blue by radiochemical methods. Finally the discovery of a fundamental intermediate product, Wursters red, together with the kinetic study of the chemical synthesis of methylene blue made it possible to determine the main stages of the reaction mechanism and to decide which of these stages could be attributed to ionising radiations in the case of the radiochemical synthesis. (author) [French] Dans le but de trouver des reactions radiochimiques susceptibles d'une application industrielle pour valoriser les dechets radioactifs provenant des reacteurs nucleaires, il a ete entrepris une etude systematique de la synthese radiochimique des colorants thiazimiques tels que le Bleu de Methylene et le Violet de Lauth dont les premiers essais ont ete effectues par Loiseleur en 1954. La premiere partie de l'etude a porte sur l'identification et le dosage des colorants formes au cours de la radiolyse

  15. The Fight for the High Ground: The U.S. Army and Interrogation during Operation Iraqi Freedom I, May 2003-April 2004

    Science.gov (United States)

    2009-06-12

    Captain Wood has stated that she " plagiarized " the interrogation policy of TF 121 (according to news reporting, the name of this SMU task force at...the time of her plagiarization ) to create a draft interrogation policy for her own interrogators at Abu Ghraib. 85 She then submitted this draft...29 Ibid. 30 Lieutenant Colonel Dean Bland, The Abu Ghraib Scandal: Impact on the Army Profession and the Intelligence Process, Academic Research

  16. PAR1 activation affects the neurotrophic properties of Schwann cells.

    Science.gov (United States)

    Pompili, Elena; Fabrizi, Cinzia; Somma, Francesca; Correani, Virginia; Maras, Bruno; Schininà, Maria Eugenia; Ciraci, Viviana; Artico, Marco; Fornai, Francesco; Fumagalli, Lorenzo

    2017-03-01

    Protease-activated receptor-1 (PAR1) is the prototypic member of a family of four G-protein-coupled receptors that signal in response to extracellular proteases. In the peripheral nervous system, the expression and/or the role of PARs are still poorly investigated. High PAR1 mRNA expression was found in the rat dorsal root ganglia and the signal intensity of PAR1 mRNA increased in response to sciatic nerve transection. In the sciatic nerve, functional PAR1 receptor was reported at the level of non-compacted Schwann cell myelin microvilli of the nodes of Ranvier. Schwann cells are the principal population of glial cells of the peripheral nervous system which myelinate axons playing an important role during axonal regeneration and remyelination. The present study was undertaken in order to determine if the activation of PAR1 affects the neurotrophic properties of Schwann cells. Our results suggest that the stimulation of PAR1 could potentiate the Schwann cell ability to favour nerve regeneration. In fact, the conditioned medium obtained from Schwann cell cultures challenged with a specific PAR1 activating peptide (PAR1 AP) displays increased neuroprotective and neurotrophic properties with respect to the culture medium from untreated Schwann cells. The proteomic analysis of secreted proteins in untreated and PAR1 AP-treated Schwann cells allowed the identification of factors differentially expressed in the two samples. Some of them (such as macrophage migration inhibitory factor, matrix metalloproteinase-2, decorin, syndecan 4, complement C1r subcomponent, angiogenic factor with G patch and FHA domains 1) appear to be transcriptionally regulated after PAR1 AP treatment as shown by RT-PCR. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Taare Zameen Par and dyslexic savants.

    Science.gov (United States)

    Chakravarty, Ambar

    2009-04-01

    The film Taare Zameen Par (Stars upon the Ground) portrays the tormented life at school and at home of a child with dyslexia and his eventual success after his artistic talents are discovered by his art teacher at the boarding school. The film hints at a curious neurocognitive phenomenon of creativity in the midst of language disability, as exemplified in the lives of people like Leonardo da Vinci and Albert Einstein, both of whom demonstrated extraordinary creativity even though they were probably affected with developmental learning disorders. It has been hypothesized that a developmental delay in the dominant hemisphere most likely 'disinhibits' the nondominant parietal lobe, unmasking talents-artistic or otherwise-in some such individuals. It has been suggested that, in remedial training, children with learning disorders be encouraged to develop such hidden talents to full capacity, rather than be subjected to the usual overemphasis on the correction of the disturbed coded symbol operations.

  18. Soudage de bois feuillus par friction rotationnelle

    OpenAIRE

    Belleville, Benoît

    2012-01-01

    Les différentes colles utilisées actuellement par l’industrie du meuble au Canada nécessitent des temps de polymérisation constituant un goulot dans la production des meubles et limitant l’atteinte de la production unitaire. Ces adhésifs synthétiques généralement issus de la pétrochimie nécessitent énormément d’énergie lors de leur confection. L’utilisation de connecteurs métalliques ou plastiques, quant à elle, limite les phases de découpage et sablage subséquentes. La présence d’adhésifs et...

  19. Monitoring system including an electronic sensor platform and an interrogation transceiver

    Science.gov (United States)

    Kinzel, Robert L.; Sheets, Larry R.

    2003-09-23

    A wireless monitoring system suitable for a wide range of remote data collection applications. The system includes at least one Electronic Sensor Platform (ESP), an Interrogator Transceiver (IT) and a general purpose host computer. The ESP functions as a remote data collector from a number of digital and analog sensors located therein. The host computer provides for data logging, testing, demonstration, installation checkout, and troubleshooting of the system. The IT transmits signals from one or more ESP's to the host computer to the ESP's. The IT host computer may be powered by a common power supply, and each ESP is individually powered by a battery. This monitoring system has an extremely low power consumption which allows remote operation of the ESP for long periods; provides authenticated message traffic over a wireless network; utilizes state-of-health and tamper sensors to ensure that the ESP is secure and undamaged; has robust housing of the ESP suitable for use in radiation environments; and is low in cost. With one base station (host computer and interrogator transceiver), multiple ESP's may be controlled at a single monitoring site.

  20. The ethics of interrogation and the American Psychological Association: A critique of policy and process

    Directory of Open Access Journals (Sweden)

    Davis Martha

    2008-01-01

    Full Text Available Abstract The Psychological Ethics and National Security (PENS task force was assembled by the American Psychological Association (APA to guide policy on the role of psychologists in interrogations at foreign detention centers for the purpose of U.S. national security. The task force met briefly in 2005, and its report was quickly accepted by the APA Board of Directors and deemed consistent with the APA Ethics Code by the APA Ethics Committee. This rapid acceptance was unusual for a number of reasons but primarily because of the APA's long-standing tradition of taking great care in developing ethical policies that protected anyone who might be impacted by the work of psychologists. Many psychological and non-governmental organizations (NGOs, as well as reputable journalists, believed the risk of harm associated with psychologist participation in interrogations at these detention centers was not adequately addressed by the report. The present critique analyzes the assumptions of the PENS report and its interpretations of the APA Ethics Code. We demonstrate that it presents only one (and not particularly representative side of a complex set of ethical issues. We conclude with a discussion of more appropriate psychological contributions to national security and world peace that better respect and preserve human rights.

  1. Duplex Interrogation by a Direct DNA Repair Protein in Search of Base Damage

    Science.gov (United States)

    Yi, Chengqi; Chen, Baoen; Qi, Bo; Zhang, Wen; Jia, Guifang; Zhang, Liang; Li, Charles J.; Dinner, Aaron R.; Yang, Cai-Guang; He, Chuan

    2012-01-01

    ALKBH2 is a direct DNA repair dioxygenase guarding mammalian genome against N1-methyladenine, N3-methylcytosine, and 1,N6-ethenoadenine damage. A prerequisite for repair is to identify these lesions in the genome. Here we present crystal structures of ALKBH2 bound to different duplex DNAs. Together with computational and biochemical analyses, our results suggest that DNA interrogation by ALKBH2 displays two novel features: i) ALKBH2 probes base-pair stability and detects base pairs with reduced stability; ii) ALKBH2 does not have nor need a “damage-checking site”, which is critical for preventing spurious base-cleavage for several glycosylases. The demethylation mechanism of ALKBH2 insures that only cognate lesions are oxidized and reversed to normal bases, and that a flipped, non-substrate base remains intact in the active site. Overall, the combination of duplex interrogation and oxidation chemistry allows ALKBH2 to detect and process diverse lesions efficiently and correctly. PMID:22659876

  2. Radioactive waste package assay facility. Volume 2. Investigation of active neutron and active gamma interrogation

    International Nuclear Information System (INIS)

    Bailey, M.; Bunce, L.J.; Findlay, D.J.S.; Jolly, J.E.; Parsons, T.V.; Sene, M.R.; Swinhoe, M.T.

    1992-01-01

    Volume 2 of this report describes the theoretical and experimental work carried out at Harwell on active neutron and active gamma interrogation of 500 litre cemented intermediate level waste drums. The design of a suitable neutron generating target in conjunction with a LINAC was established. Following theoretical predictions of likely neutron responses, an experimental assay assembly was built. Responses were measured for simulated drums of ILW, based on CAGR, Magnox and PCM wastes. Good correlations were established between quantities of 235 -U, nat -U and D 2 O contained in the drums, and the neutron signals. Expected sensitivities are -1g of fissile actinide and -100g of total actinide. A measure of spatial distribution is obtainable. The neutron time spectra obtained during neutron interrogation were more complex than expected, and more analysis is needed. Another area of discrepancy is the difference between predicted and measured thermal neutron flux in the drum. Clusters of small 3 He proportional counters were found to be much superior for fast neutron detection than larger diameter counters. It is necessary to ensure constancy of electron beam position relative to target(s) and drum, and prudent to measure the target neutron or gamma output as appropriate. 59 refs., 77 figs., 11 tabs

  3. Dynamic Sensor Interrogation Using Wavelength-Swept Laser with a Polygon-Scanner-Based Wavelength Filter

    Science.gov (United States)

    Kwon, Yong Seok; Ko, Myeong Ock; Jung, Mi Sun; Park, Ik Gon; Kim, Namje; Han, Sang-Pil; Ryu, Han-Cheol; Park, Kyung Hyun; Jeon, Min Yong

    2013-01-01

    We report a high-speed (∼2 kHz) dynamic multiplexed fiber Bragg grating (FBG) sensor interrogation using a wavelength-swept laser (WSL) with a polygon-scanner-based wavelength filter. The scanning frequency of the WSL is 18 kHz, and the 10 dB scanning bandwidth is more than 90 nm around a center wavelength of 1,540 nm. The output from the WSL is coupled into the multiplexed FBG array, which consists of five FBGs. The reflected Bragg wavelengths of the FBGs are 1,532.02 nm, 1,537.84 nm, 1,543.48 nm, 1,547.98 nm, and 1,553.06 nm, respectively. A dynamic periodic strain ranging from 500 Hz to 2 kHz is applied to one of the multiplexed FBGs, which is fixed on the stage of the piezoelectric transducer stack. Good dynamic performance of the FBGs and recording of their fast Fourier transform spectra have been successfully achieved with a measuring speed of 18 kHz. The signal-to-noise ratio and the bandwidth over the whole frequency span are determined to be more than 30 dB and around 10 Hz, respectively. We successfully obtained a real-time measurement of the abrupt change of the periodic strain. The dynamic FBG sensor interrogation system can be read out with a WSL for high-speed and high-sensitivity real-time measurement. PMID:23899934

  4. Characterization of lipid films by an angle-interrogation surface plasmon resonance imaging device.

    Science.gov (United States)

    Liu, Linlin; Wang, Qiong; Yang, Zhong; Wang, Wangang; Hu, Ning; Luo, Hongyan; Liao, Yanjian; Zheng, Xiaolin; Yang, Jun

    2015-04-01

    Surface topographies of lipid films have an important significance in the analysis of the preparation of giant unilamellar vesicles (GUVs). In order to achieve accurately high-throughput and rapidly analysis of surface topographies of lipid films, a homemade SPR imaging device is constructed based on the classical Kretschmann configuration and an angle interrogation manner. A mathematical model is developed to accurately describe the shift including the light path in different conditions and the change of the illumination point on the CCD camera, and thus a SPR curve for each sampling point can also be achieved, based on this calculation method. The experiment results show that the topographies of lipid films formed in distinct experimental conditions can be accurately characterized, and the measuring resolution of the thickness lipid film may reach 0.05 nm. Compared with existing SPRi devices, which realize detection by monitoring the change of the reflective-light intensity, this new SPRi system can achieve the change of the resonance angle on the entire sensing surface. Thus, it has higher detection accuracy as the traditional angle-interrogation SPR sensor, with much wider detectable range of refractive index. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. [Performance of a standardized interrogation to improve the screening of Chlamydia trachomatis infection].

    Science.gov (United States)

    Grandcolin, S; de Hauteclocque, A; Lafoscade, A; Fritel, X

    2015-10-01

    To estimate the performance of a standardized interrogation tool facilitating the detection and screening of patients for the Chlamydia trachomatis infection, to estimate the prevalence of the infection in the family planning population studied. Prospective observational study, including the patients who had a consultation in the abortion center in the CHU of Poitiers. A sampling of the cervix was systematically carried out after the standardized interrogation in search of four clinical signs. The samples were analyzed by genetic amplification. Three hundred and eighty-six women were included and 56 (14.5 %) infections were identified. The medical history questionnaire was relatively effective for 2 or 3 clinical signs. The positive predictive value (PPV) was respectively 34.8 % and 53.8 % and was very relevant for 4 clinical signs with PPV at 83.3 % [CI 95 %: 74-93 %]. Among the infected women, 48.2 % had no clinical sign revealed by the medical history questionnaire. The presence of any clinical sign was strongly associated with the C. trachomatis infection (Pinterrogation are all significantly associated with the C. trachomatis infection. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  6. Digitally controlled chirped pulse laser for sub-terahertz-range fiber structure interrogation.

    Science.gov (United States)

    Chen, Zhen; Hefferman, Gerald; Wei, Tao

    2017-03-01

    This Letter reports a sweep velocity-locked laser pulse generator controlled using a digital phase-locked loop (DPLL) circuit. This design is used for the interrogation of sub-terahertz-range fiber structures for sensing applications that require real-time data collection with millimeter-level spatial resolution. A distributed feedback laser was employed to generate chirped laser pulses via injection current modulation. A DPLL circuit was developed to lock the optical frequency sweep velocity. A high-quality linearly chirped laser pulse with a frequency excursion of 117.69 GHz at an optical communication band was demonstrated. The system was further adopted to interrogate a continuously distributed sub-terahertz-range fiber structure (sub-THz-fs) for sensing applications. A strain test was conducted in which the sub-THz-fs showed a linear response to longitudinal strain change with predicted sensitivity. Additionally, temperature testing was conducted in which a heat source was used to generate a temperature distribution along the fiber structure to demonstrate its distributed sensing capability. A Gaussian temperature profile was measured using the described system and tracked in real time, as the heat source was moved.

  7. Spectrum interrogation of fiber acoustic sensor based on self-fitting and differential method.

    Science.gov (United States)

    Fu, Xin; Lu, Ping; Ni, Wenjun; Liao, Hao; Wang, Shun; Liu, Deming; Zhang, Jiangshan

    2017-02-20

    In this article, we propose an interrogation method of fiber acoustic sensor to recover the time-domain signal from the sensor spectrum. The optical spectrum of the sensor will show a ripple waveform when responding to acoustic signal due to the scanning process in a certain wavelength range. The reason behind this phenomenon is the dynamic variation of the sensor spectrum while the intensity of different wavelength is acquired at different time in a scanning period. The frequency components can be extracted from the ripple spectrum assisted by the wavelength scanning speed. The signal is able to be recovered by differential between the ripple spectrum and its self-fitted curve. The differential process can eliminate the interference caused by environmental perturbations such as temperature or refractive index (RI), etc. The proposed method is appropriate for fiber acoustic sensors based on gratings or interferometers. A long period grating (LPG) is adopted as an acoustic sensor head to prove the feasibility of the interrogation method in experiment. The ability to compensate the environmental fluctuations is also demonstrated.

  8. An enhanced functional interrogation/manipulation of intracellular signaling pathways with the peptide 'stapling' technology.

    Science.gov (United States)

    He, Y; Chen, D; Zheng, W

    2015-11-12

    Specific protein-protein interactions (PPIs) constitute a key underlying mechanism for the presence of a multitude of intracellular signaling pathways, which are essential for the survival of normal and cancer cells. Specific molecular blockers for a crucial PPI would therefore be invaluable tools for an enhanced functional interrogation of the signaling pathway harboring this particular PPI. On the other hand, if a particular PPI is essential for the survival of cancer cells but is absent in or dispensable for the survival of normal cells, its specific molecular blockers could potentially be developed into effective anticancer therapeutics. Due to the flat and extended PPI interface, it would be conceivably difficult for small molecules to achieve an effective blockade, a problem which could be potentially circumvented with peptides or proteins. However, the well-documented proteolytic instability and cellular impermeability of peptides and proteins in general would make their developing into effective intracellular PPI blockers quite a challenge. With the advent of the peptide 'stapling' technology which was demonstrated to be able to stabilize the α-helical conformation of a peptide via bridging two neighboring amino-acid side chains with a 'molecular staple', a linear parent peptide could be transformed into a stronger PPI blocker with enhanced proteolytic stability and cellular permeability. This review will furnish an account on the peptide 'stapling' technology and its exploitation in efforts to achieve an enhanced functional interrogation or manipulation of intracellular signaling pathways especially those that are cancer relevant.

  9. Development and application of a hybrid transport methodology for active interrogation systems

    Energy Technology Data Exchange (ETDEWEB)

    Royston, K.; Walters, W.; Haghighat, A. [Nuclear Engineering Program, Department of Mechanical Engineering, Virginia Tech., 900 N Glebe Rd., Arlington, VA 22203 (United States); Yi, C.; Sjoden, G. [Nuclear and Radiological Engineering, Georgia Tech, 801 Ferst Drive, Atlanta, GA 30332 (United States)

    2013-07-01

    A hybrid Monte Carlo and deterministic methodology has been developed for application to active interrogation systems. The methodology consists of four steps: i) neutron flux distribution due to neutron source transport and subcritical multiplication; ii) generation of gamma source distribution from (n, 7) interactions; iii) determination of gamma current at a detector window; iv) detection of gammas by the detector. This paper discusses the theory and results of the first three steps for the case of a cargo container with a sphere of HEU in third-density water cargo. To complete the first step, a response-function formulation has been developed to calculate the subcritical multiplication and neutron flux distribution. Response coefficients are pre-calculated using the MCNP5 Monte Carlo code. The second step uses the calculated neutron flux distribution and Bugle-96 (n, 7) cross sections to find the resulting gamma source distribution. In the third step the gamma source distribution is coupled with a pre-calculated adjoint function to determine the gamma current at a detector window. The AIMS (Active Interrogation for Monitoring Special-Nuclear-Materials) software has been written to output the gamma current for a source-detector assembly scanning across a cargo container using the pre-calculated values and taking significantly less time than a reference MCNP5 calculation. (authors)

  10. Switching Transient Generation in Surface Interrogation Scanning Electrochemical Microscopy and Time-of-Flight Techniques.

    Science.gov (United States)

    Ahn, Hyun S; Bard, Allen J

    2015-12-15

    In surface interrogation scanning electrochemical microscopy (SI-SECM), fine and accurate control of the delay time between substrate generation and tip interrogation (tdelay) is crucial because tdelay defines the decay time of the reactive intermediate. In previous applications of the SI-SECM, the resolution in the control of tdelay has been limited to several hundreds of milliseconds due to the slow switching of the bipotentiostat. In this work, we have improved the time resolution of tdelay control up to ca. 1 μs, enhancing the SI-SECM to be competitive in the time domain with the decay of many reactive intermediates. The rapid switching SI-SECM has been implemented in a substrate generation-tip collection time-of-flight (SG-TC TOF) experiment of a solution redox mediator, and the results obtained from the experiment exhibited good agreement with that obtained from digital simulation. The reaction rate constant of surface Co(IV) on oxygen-evolving catalyst film, which was inaccessible thus far due to the lack of tdelay control, has been measured by the rapid switching SI-SECM.

  11. Reduced representation approaches to interrogate genome diversity in large repetitive plant genomes.

    Science.gov (United States)

    Hirsch, Cory D; Evans, Joseph; Buell, C Robin; Hirsch, Candice N

    2014-07-01

    Technology and software improvements in the last decade now provide methodologies to access the genome sequence of not only a single accession, but also multiple accessions of plant species. This provides a means to interrogate species diversity at the genome level. Ample diversity among accessions in a collection of species can be found, including single-nucleotide polymorphisms, insertions and deletions, copy number variation and presence/absence variation. For species with small, non-repetitive rich genomes, re-sequencing of query accessions is robust, highly informative, and economically feasible. However, for species with moderate to large sized repetitive-rich genomes, technical and economic barriers prevent en masse genome re-sequencing of accessions. Multiple approaches to access a focused subset of loci in species with larger genomes have been developed, including reduced representation sequencing, exome capture and transcriptome sequencing. Collectively, these approaches have enabled interrogation of diversity on a genome scale for large plant genomes, including crop species important to worldwide food security. © The Author 2014. Published by Oxford University Press. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  12. The ethics of interrogation and the American Psychological Association: a critique of policy and process.

    Science.gov (United States)

    Olson, Brad; Soldz, Stephen; Davis, Martha

    2008-01-29

    The Psychological Ethics and National Security (PENS) task force was assembled by the American Psychological Association (APA) to guide policy on the role of psychologists in interrogations at foreign detention centers for the purpose of U.S. national security. The task force met briefly in 2005, and its report was quickly accepted by the APA Board of Directors and deemed consistent with the APA Ethics Code by the APA Ethics Committee. This rapid acceptance was unusual for a number of reasons but primarily because of the APA's long-standing tradition of taking great care in developing ethical policies that protected anyone who might be impacted by the work of psychologists. Many psychological and non-governmental organizations (NGOs), as well as reputable journalists, believed the risk of harm associated with psychologist participation in interrogations at these detention centers was not adequately addressed by the report. The present critique analyzes the assumptions of the PENS report and its interpretations of the APA Ethics Code. We demonstrate that it presents only one (and not particularly representative) side of a complex set of ethical issues. We conclude with a discussion of more appropriate psychological contributions to national security and world peace that better respect and preserve human rights.

  13. Peak wavelength interrogation of fiber Bragg grating sensors during impact events

    International Nuclear Information System (INIS)

    Park, Chun; Peters, Kara; Zikry, Mohammed; Haber, Todd; Schultz, Stephen; Selfridge, Richard

    2010-01-01

    In this paper, we embed fiber Bragg grating (FBG) sensors in graphite fiber–epoxy woven composite laminates to detect evolving damage modes. The peak wavelengths of the FBG sensors are interrogated at 625 and 295 kHz, while the laminates are subjected to 11.0 J low-velocity impact events. It is demonstrated that 295 kHz interrogation is sufficient for accurately collecting the dynamic response of the sensors. The FBG sensors embedded at the laminate midplanes successfully reconstructed the global laminate response to impact. The maximum and full width at half-maximum (FWHM) for the relative strain histories demonstrated the same trends as the maximum and FWHM of the contact force histories measured from the impactor. More noise was present in the strain histories obtained from the FBG sensors than the contact force histories, as the embedded FBGs were sensitive to local perturbations in the stress state. The FBG sensors embedded below the midplane of the laminate were closer to the damage regions and measured complex strain histories. In one case, this strain history revealed the presence of delamination

  14. Electronics system for transuranic waste assays using a photon interrogation technique

    International Nuclear Information System (INIS)

    Johnson, L.O.; Lawrence, R.S.

    1979-12-01

    This report documents the development of electronics for a neutron detection system used in experiments to demonstrate the feasibility of a photon interrogation technique for transuranic (TRU) waste assays. The system consists of the neutron detection and signal conditioning circuits, variable time-gate generators, and a data acquisition system. The data acquisition system is configured using commercially available scalers, timers, teletype, and control components. The remainder of the system, with the exception of the neutron detectors, uses components designed in-house. The neutron detection system consists of 3 He proportional counters installed in a polyethylene moderator assembly. The counters are direct-coupled to a high-count-rate, current-sensitive preamplifier. The preamplifier and an additional two-stage amplifier are also installed in the moderator assembly. Signal conditioning includes baseline restoration and fast discrimination. A variable time-gate generator with logic gates allows for separation of prompt and delayed neutron counts, and generation of prompt and delayed deadtimes. The 3 He proportional counters will detect not only the neutrons from the TRU waste sample, but also the high-energy photons used to induce fission in the sample. The burst of photons (gamma flash) tends to overload and paralyze the electronics. This system has been designed to recover from a worst-case gamma flash overload within 10 microseconds. The system has met all the requirements generated for the photon interrogation experiments

  15. "What Exactly Is a Black?": Interrogating the Reality of Race in Jean Genet's The Blacks

    Directory of Open Access Journals (Sweden)

    Debby Thompson

    2002-06-01

    Full Text Available On the dedication page of The Blacks , Genet writes "One evening an actor asked me to write a play for an all-black cast. But what exactly is a black? First of all, what's his color?" Prefiguring major issues and paradoxes of African American cultural studies today, The Blacks insists on the very real ways in which the black/white racial binary, like the very concept of race itself, is lived and socially enforced, and at the same time argues that the binary is ultimately a fiction, made real through performative reification. Genet's "clown show," ambiguously reversing the blackface minstrelsy tradition, dramatizes how racial identity can become internalized and naturalized through cultural myths of interracial rape and colonialist narratives of a "heart of darkness," an imaginary site from which "black essence" arises. These racist performance traditions and narratives are so powerful and resilient that attempts to protest them become subtle and unwitting ways of re-creating them. The Blacks' parody of the minstrel tradition to interrogate all racial identity is so permanently suspended in a dialectic of both reinforcing the black/white binary and invalidating it, that the play's strategies present vital paradigms for the study of other and diverse interrogations of racial ontologies.

  16. Interrogating scarcity: how to think about ‘resource-scarce settings’

    Science.gov (United States)

    Schrecker, Ted

    2013-01-01

    The idea of resource scarcity permeates health ethics and health policy analysis in various contexts. However, health ethics inquiry seldom asks—as it should—why some settings are ‘resource-scarce’ and others not. In this article I describe interrogating scarcity as a strategy for inquiry into questions of resource allocation within a single political jurisdiction and, in particular, as an approach to the issue of global health justice in an interconnected world. I demonstrate its relevance to the situation of low- and middle-income countries (LMICs) with brief descriptions of four elements of contemporary globalization: trade agreements; the worldwide financial marketplace and capital flight; structural adjustment; imperial geopolitics and foreign policy. This demonstration involves not only health care, but also social determinants of health. Finally, I argue that interrogating scarcity provides the basis for a new, critical approach to health policy at the interface of ethics and the social sciences, with specific reference to market fundamentalism as the value system underlying contemporary globalization. PMID:22899597

  17. Development of a Liquid Scintillator-Based Active Interrogation System for LEU Fuel Assemblies

    International Nuclear Information System (INIS)

    Lavietes, Anthony D.; Plenteda, Romano; Mascahrenas, Nicholas; Cronholm, L. Marie; Aspinall, Michael; Joyce, Malcolm; Tomanin, Alice; Peerani, Paolo

    2013-06-01

    The IAEA, in collaboration with the Joint Research Center (Ispra, IT) and Hybrid Instruments (Lancaster, UK), has developed a full scale, liquid scintillator-based active interrogation system to determine uranium (U) mass in fresh fuel assemblies. The system implements an array of moderate volume (∼1000 ml) liquid scintillator detectors, a multichannel pulse shape discrimination (PSD) system, and a high-speed data acquisition and signal processing system to assess the U content of fresh fuel assemblies. Extensive MCNPX-PoliMi modelling has been carried out to refine the system design and optimize the detector performance. These measurements, traditionally performed with 3 He-based assay systems (e.g., Uranium Neutron Coincidence Collar [UNCL], Active Well Coincidence Collar [AWCC]), can now be performed with higher precision in a fraction of the acquisition time. The system uses a high-flash point, non-hazardous scintillating fluid (EJ309) enabling their use in commercial nuclear facilities and achieves significantly enhanced performance and capabilities through the combination of extremely short gate times, adjustable energy detection threshold, real-time PSD electronics, and high-speed, FPGA-based data acquisition. Given the possible applications, this technology is also an excellent candidate for the replacement of select 3 He-based systems. Comparisons to existing 3 He-based active interrogation systems are presented where possible to provide a baseline performance reference. This paper will describe the laboratory experiments and associated modelling activities undertaken to develop and initially test the prototype detection system. (authors)

  18. Interrogation and mitigation of polarization effects for standard and birefringent FBGs

    Science.gov (United States)

    Ibrahim, Selwan K.; Van Roosbroeck, Jan; O'Dowd, John A.; Van Hoe, Bram; Lindner, Eric; Vlekken, Johan; Farnan, Martin; Karabacak, Devrez M.; Singer, Johannes M.

    2016-05-01

    Optical sensors based on Fiber Bragg Gratings (FBGs) are used in several applications and industries. Several inscription techniques and type of fibers can be used. However, depending on the writing process, type of fiber used and the packaging of the sensor a Polarization Dependent Frequency Shift (PDFS) can often be observed with polarized tunable laser based optical interrogators. Here we study the PDFS of the FBG peak for the different FBG types. A PDFS of 20pm was observed across the FBGs. To mitigate and reduce this effect we propose a polarization mitigation technique which relies on a synchronous polarization switch to reduce the effect typically by a factor greater than 4. In other scenarios the sensor itself is designed to be birefringent (Bi-FBG) to allow pressure and/or simultaneous temperature and strain measurements. Using the same polarization switch we demonstrate how we can interrogate the Bi-FBGs with high accuracy to enable high performance of such sensors to be achievable.

  19. The Application of Existing Oceanographic Knowledge to the Problem of Radioactive Waste Disposal into the Sea; Applicationdes Connaissances Oceanographiques Actuelles au Probleme de l'Elimination de Dechets Radioactifs dans la Mer; 0418 0421 041f 0414 ; Aplicacion de los Conocimientos Oceanograficos Actuales al Problema de la Evacuacion de Desechos Radiactivos en el Mar

    Energy Technology Data Exchange (ETDEWEB)

    Pritchard, D. W. [Johns Hopkins University, Baltimore, MD (United States)

    1960-07-01

    quantites assez importantes de dechets emballes (de l'ordre de plusieurs megacuries par an) sans compromettre l'utilisation par l'homme des produits de la mer. On pourrait eliminer sans danger sur le plateau continental des dechets emballes de faible activite, de l'ordre de plusieurs centaines de curies par an et par lieu d'evacuation. Les navires a propulsion nucleaire peuvent decharger sans trop de risques dans les couches superficielles de la haute mer plusieurs centaines de curies avec les matieres echangeuses d'ions usees. L'auteur etudie en particulier J'influence que peut avoir sur les milieux voisins des rivages et des estuaires l'exploitation de navires a propulsion nucleaire. La troisieme partie du memoire contient l'expose succinct de certaines recherches oceanographiques faites actuellement aux Etats-Unis, et qui peuvent eclairer le probleme de l'elimination des dechets radioactifs. (author) [Spanish] La memoria se divide en tres partes principales. En la primera, el autor expone los criterios seguidos para abordar el problema general de la evacuacion de sustancias radiactivas en el mar. Indica aquellos sectores en los que se requieren conocimientos oceanograficos y estudia sucintamente el estado de nuestros conocimientos actuales en estos sectores. En la segunda parte, los conocimientos oceanograficos existentes se aplican a los problemas de evacuacion de desechos, inclusive sus aspectos fisicos, quimicos y biologicos. El autor demuestra que, sobre la base de los conocimientos oceanograficos actuales, la evacuacion en las profundidades del mar de grandes cantidades (del orden de los megacuries por ano) de desechos envasados puede hacerse sin comprometer la utilizacion del mar y de sus productos por el hombre. Los desechos envasados de baja actividad, en cantidades del orden de varios centenares de curies por ano y por lugar de eliminacion, podran evacuarse en la plataforma continental. Asimismo, podra permitirse la evacuacion en las capas superficiales de la

  20. Radioactive Waste Control at the United Kingdom Atomic Energy Research Establishment, Harwell; Traitement des Dechets Radioactifs au Centre de Recherche sur l'Energie Atomique de Harwell; 041a 041e 041d 0422 0420 041e 041b 042c 0417 0410 0423 0414 ; Control de Desechos Radiactivos en el A.E.R.E., Harwell

    Energy Technology Data Exchange (ETDEWEB)

    Burns, R. H. [United Kingdom Atomic Energy Authority (United Kingdom)

    1960-07-01

    The paper outlines the present practices in the control and treatment of radioactive wastes at Harwell. The large-volume, low-level active liquid effluent is treated by phosphate coagulation methods and, eventually, discharged to the River Thames. The medium-level wastes are segregated and undergo a two-stage chemical treatment followed by passage through columns of Vermiculite. The latter process has been found to be effective in removing radoicaesium, which is not dealt with efficiently by the precipitation methods used. Liquid wastes with a high- activity content are stored and a new plant, incorporating chemical treatment, ion exchange and evaporation, is being installed. The chemical sludges formed in the treatment processes are dumped at sea after de-watering by filtration. The contaminated solid waste is either stored or disposed of at sea. It is important to reduce the volume as much as possible and the methods employed include pressure baling, melting and incineration of combustible matter. Small quantities of activity are discharged to the atmosphere through exhaust stacks. The cleaning of this discharge air is commonly achieved by the use of high-efficiency filters or liquid scrubbing systems. Regular stack monitoring is carried out and this is backed up by a comprehensive district sampling programme. (author) [French] L'auteur decrit les methodes de controle et de traitement des dechets radioactifs qui sont appliquees au Centre de Harwell. Le volume considerable des effluents liquides de faible activite est traite par des methodes de coagulation au moyen des phosphates, puis evacue dans la Tamise. Apres separation, les dechets d'activite moyenne sont soumis a un traitement chimique en deux temps, avant de traverser des colonnes de Vermiculite. On a constate que ce dernier processus eliminait le radio- cesium, ce que les methodes de precipitation utilisees ne permettent pas de faire de maniere efficace. Les dechets liquides d'activite intense sont

  1. TMS suppression of right pars triangularis, but not pars opercularis, improves naming in aphasia

    Science.gov (United States)

    Naeser, Margaret A.; Martin, Paula I.; Theoret, Hugo; Kobayashi, Masahito; Fregni, Felipe; Nicholas, Marjorie; Tormos, Jose M.; Steven, Megan S.; Baker, Errol H.; Pascual-Leone, Alvaro

    2011-01-01

    This study sought to discover if an optimum 1 cm2 area in the non-damaged right hemisphere (RH) was present, which could temporarily improve naming in chronic, nonfluent aphasia patients when suppressed with repetitive transcranial magnetic stimulation (rTMS). Ten minutes of slow, 1 Hz rTMS was applied to suppress different RH ROIs in eight aphasia cases. Picture naming and response time (RT) were examined before, and immediately after rTMS. In aphasia patients, suppression of right pars triangularis (PTr) led to significant increase in pictures named, and significant decrease in RT. Suppression of right pars opercularis (POp), however, led to significant increase in RT, but no change in number of pictures named. Eight normals named all pictures correctly; similar to aphasia patients, RT significantly decreased following rTMS to suppress right PTr, versus right POp. Differential effects following suppression of right PTr versus right POp suggest different functional roles for these regions. PMID:21864891

  2. ParABS system in chromosome partitioning in the bacterium Myxococcus xanthus.

    Directory of Open Access Journals (Sweden)

    Antonio A Iniesta

    Full Text Available Chromosome segregation is an essential cellular function in eukaryotic and prokaryotic cells. The ParABS system is a fundamental player for a mitosis-like process in chromosome partitioning in many bacterial species. This work shows that the social bacterium Myxococcus xanthus also uses the ParABS system for chromosome segregation. Its large prokaryotic genome of 9.1 Mb contains 22 parS sequences near the origin of replication, and it is shown here that M. xanthus ParB binds preferentially to a consensus parS sequence in vitro. ParB and ParA are essential for cell viability in M. xanthus as in Caulobacter crescentus, but unlike in many other bacteria. Absence of ParB results in anucleate cells, chromosome segregation defects and loss of viability. Analysis of ParA subcellular localization shows that it clusters at the poles in all cells, and in some, in the DNA-free cell division plane between two chromosomal DNA masses. This ParA localization pattern depends on ParB but not on FtsZ. ParB inhibits the nonspecific interaction of ParA with DNA, and ParA colocalizes with chromosomal DNA only when ParB is depleted. The subcellular localization of ParB suggests a single ParB-parS complex localized at the edge of the nucleoid, next to a polar ParA cluster, with a second ParB-parS complex migrating after the replication of parS takes place to the opposite nucleoid edge, next to the other polar ParA cluster.

  3. Concerning the dynamic instability of actin homolog ParM

    International Nuclear Information System (INIS)

    Popp, David; Yamamoto, Akihiro; Iwasa, Mitsusada; Narita, Akihiro; Maeda, Kayo; Maeda, Yuichiro

    2007-01-01

    Using in vitro TIRF- and electron-microscopy, we reinvestigated the dynamics of native ParM, a prokaryotic DNA segregation protein and actin homolog. In contrast to a previous study, which used a cysteine ParM mutant, we find that the polymerization process of wild type ATP-ParM filaments consists of a polymerization phase and a subsequent steady state phase, which is dynamically unstable, like that of microtubules. We find that the apparent bidirectional polymerization of ParM, is not due to the intrinsic nature of this filament, but results from ParM forming randomly oriented bundles in the presence of crowding agents. Our results imply, that in the bacterium, ParM filaments spontaneously form bipolar bundles. Due to their intrinsic dynamic instability, ParM bundles can efficiently 'search' the cytoplasmic lumen for DNA, bind it equally well at the bipolar ends and segregate it approximately symmetrically, by the insertion of ParM subunits at either end

  4. The protein kinase SIK downregulates the polarity protein Par3

    DEFF Research Database (Denmark)

    Vanlandewijck, Michael; Dadras, Mahsa Shahidi; Lomnytska, Marta

    2018-01-01

    on Par3. Functionally, this mechanism impacts on tight junction downregulation. Furthermore, SIK contributes to the loss of epithelial polarity and examination of advanced and invasive human cancers of diverse origin displayed high levels of SIK expression and a corresponding low expression of Par3...

  5. The simultaneous neutron and photon interrogation method for fissile and non-fissile element separation in radioactive waste drums

    International Nuclear Information System (INIS)

    Jallu, F.; Lyoussi, A.; Passard, C.; Payan, E.; Recroix, H.; Nurdin, G.; Buisson, A.; Allano, J.

    2000-01-01

    Measuring α-emitters such as ( 234,235,236,238 U, 238,239,240,242,244 Pu, 237 Np, 241,243 Am, ...), in solid radioactive waste allows us to quantify the α-activity in a drum and then to classify it. The simultaneous photon and neutron interrogation experiment (SIMPHONIE) method dealt with in this paper, combines both active neutron interrogation and induced photofission interrogation techniques simultaneously. Its purpose is to quantify fissile ( 235 U, 239,241 Pu, ...) and non-fissile ( 236,238 U, 238,240 Pu, ...) elements separately in only one measurement. This paper presents the principle of the method, the experimental setup, and the first experimental results obtained using the DGA/ETCA Linac and MiniLinatron pulsed linear electron accelerators located at Arcueil, France. First studies were carried out with U and Pu bare samples

  6. A Fiber Bragg Grating Sensor Interrogation System Based on a Linearly Wavelength-Swept Thermo-Optic Laser Chip

    Science.gov (United States)

    Lee, Hyung-Seok; Lee, Hwi Don; Kim, Hyo Jin; Cho, Jae Du; Jeong, Myung Yung; Kim, Chang-Seok

    2014-01-01

    A linearized wavelength-swept thermo-optic laser chip was applied to demonstrate a fiber Bragg grating (FBG) sensor interrogation system. A broad tuning range of 11.8 nm was periodically obtained from the laser chip for a sweep rate of 16 Hz. To measure the linear time response of the reflection signal from the FBG sensor, a programmed driving signal was directly applied to the wavelength-swept laser chip. The linear wavelength response of the applied strain was clearly extracted with an R-squared value of 0.99994. To test the feasibility of the system for dynamic measurements, the dynamic strain was successfully interrogated with a repetition rate of 0.2 Hz by using this FBG sensor interrogation system. PMID:25177803

  7. Demonstration of an ultrasensitive refractive-index plasmonic sensor by enabling its quadrupole resonance in phase interrogation.

    Science.gov (United States)

    Lee, Hsin-Cheng; Li, Chung-Tien; Chen, How-Foo; Yen, Ta-Jen

    2015-11-15

    We present an ultrasensitive plasmonic sensing system by introducing a nanostructured X-shaped plasmonic sensor (XPS) and measuring its localized optical properties in phase interrogation. Our tailored XPS exhibits two major resonant modes of a low-order dipole and a high-order quadrupole, between which the quadrupole resonance allows an ultrahigh sensitivity, due to its higher quality factor. Furthermore, we design an in-house common-path phase-interrogation system, in contrast to conventional wavelength-interrogation methods, to achieve greater sensing capability. The experimental measurement shows that the sensing resolution of the XPS reaches 1.15×10(-6) RIU, not only two orders of magnitude greater than the result of the controlled extinction measurement (i.e., 9.90×10(-5) RIU), but also superior than current reported plasmonic sensors.

  8. Technical and Administrative Considerations in the Management of Radioactive Wastes; Considerations Techniques et Administratives Relatives au Traitement des Dechets Radioactifs; 0422 0415 0425 041d 0418 0427 0415 0421 041a 0414 ; Aspectos Tecnicos y Administrativos de la Manipulacion de Desechos Radiactivos

    Energy Technology Data Exchange (ETDEWEB)

    Wolman, Abel [Johns Hopkins University, Baltimore, MD (United States); Division of Reactor Development, U.S. Atomic Energy Commission, Washington, DC (United States); Lieberman, Joseph A. [Environmental and Sanitary Engineering Branch, Division of Reactor Development, U.S. Atomic Energy Commission, Washington, DC (United States)

    1960-07-01

    administratifs du traitement des dechets en rattachant cette analyse aux mesures qu'il pourrait etre necessaire de prendre dans l'avenir pour assurer un traitement et un controle efficaces, sur le plan administratif et juridique, des effluents radioactifs resultant de la production d'energie atomique. Les auteurs repartissent tout d'abord en de larges categories les differentes sortes de dechets pour bien souligner que le probleme de leur traitement presente de multiples aspects et qu'on ne saurait en donner une solution unique. Ils examinent rapidement le role des differents milieux dans le choix des methodes de traitement des dechets et definissent les procedes fondamentaux de controle (dilution et dispersion, concentration et confinement). Les auteurs distinguent entre les normes fondamentales de protection radiologique et les criteres de fonctionnement qui doivent etre fixes pour realiser le controle des effluents de facon a veiller a ce que les normes fondamentales soient respectees. Les auteurs examinent les progres realises en matiere de normes et criteres ainsi que l'application de ceux-ci dans l'etablissement de reglements de sante et de securite et la mise au point de procedures administratives et juridiques. A cet egard, ils signalent les avantages que presente, du point de vue de l'opinion publique et du travail administratif, l'utilisation la plus large des textes legislatifs et des procedures administratives dans les services deja crees aux divers echelons de l'autorite. Malgre l'importance des depenses qu'entrainent le traitement et l'elimination des dechets radioactifs, le cout par unite d'energie electrique produite ne represente qu'une partie relativement restreinte du cout total par unite d'energie. Les auteurs indiquent d'autres facteurs economiques qui jouent un role dans la manipulation et l'elimination des dechets, notamment en fonction de l'emplacement de l'usine et du point d'evacuation. En outre, ils examinent d'autres aspects du traitement des dechets

  9. Recombination in the human Pseudoautosomal region PAR1.

    Directory of Open Access Journals (Sweden)

    Anjali G Hinch

    2014-07-01

    Full Text Available The pseudoautosomal region (PAR is a short region of homology between the mammalian X and Y chromosomes, which has undergone rapid evolution. A crossover in the PAR is essential for the proper disjunction of X and Y chromosomes in male meiosis, and PAR deletion results in male sterility. This leads the human PAR with the obligatory crossover, PAR1, to having an exceptionally high male crossover rate, which is 17-fold higher than the genome-wide average. However, the mechanism by which this obligatory crossover occurs remains unknown, as does the fine-scale positioning of crossovers across this region. Recent research in mice has suggested that crossovers in PAR may be mediated independently of the protein PRDM9, which localises virtually all crossovers in the autosomes. To investigate recombination in this region, we construct the most fine-scale genetic map containing directly observed crossovers to date using African-American pedigrees. We leverage recombination rates inferred from the breakdown of linkage disequilibrium in human populations and investigate the signatures of DNA evolution due to recombination. Further, we identify direct PRDM9 binding sites using ChIP-seq in human cells. Using these independent lines of evidence, we show that, in contrast with mouse, PRDM9 does localise peaks of recombination in the human PAR1. We find that recombination is a far more rapid and intense driver of sequence evolution in PAR1 than it is on the autosomes. We also show that PAR1 hotspot activities differ significantly among human populations. Finally, we find evidence that PAR1 hotspot positions have changed between human and chimpanzee, with no evidence of sharing among the hottest hotspots. We anticipate that the genetic maps built and validated in this work will aid research on this vital and fascinating region of the genome.

  10. High-fidelity MCNP modeling of a D-T neutron generator for active interrogation of special nuclear material

    International Nuclear Information System (INIS)

    Katalenich, Jeff; Flaska, Marek; Pozzi, Sara A.; Hartman, Michael R.

    2011-01-01

    Fast and robust methods for interrogation of special nuclear material (SNM) are of interest to many agencies and institutions in the United States. It is well known that passive interrogation methods are typically sufficient for plutonium identification because of a relatively high neutron production rate from 240 Pu . On the other hand, identification of shielded uranium requires active methods using neutron or photon sources . Deuterium-deuterium (2.45 MeV) and deuterium-tritium (14.1 MeV) neutron-generator sources have been previously tested and proven to be relatively reliable instruments for active interrogation of nuclear materials . In addition, the newest generators of this type are small enough for applications requiring portable interrogation systems. Active interrogation techniques using high-energy neutrons are being investigated as a method to detect hidden SNM in shielded containers . Due to the thickness of some containers, penetrating radiation such as high-energy neutrons can provide a potential means of probing shielded SNM. In an effort to develop the capability to assess the signal seen from various forms of shielded nuclear materials, University of Michigan Neutron Science Laboratory's D-T neutron generator and its shielding were accurately modeled in MCNP. The generator, while operating at nominal power, produces approximately 1x10 10 neutrons/s, a source intensity which requires a large amount of shielding to minimize the dose rates around the generator. For this reason, the existing shielding completely encompasses the generator and does not include beam ports. Therefore, several MCNP simulations were performed to estimate the yield of uncollided 14.1-MeV neutrons from the generator for active interrogation experiments. Beam port diameters of 5, 10, 15, 20, and 25 cm were modeled to assess the resulting neutron fluxes. The neutron flux outside the beam ports was estimated to be approximately 2x10 4 n/cm 2 s.

  11. Active Interrogation using Photofission Technique for Nuclear Materials Control and Accountability

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Haori [Oregon State Univ., Corvallis, OR (United States)

    2016-03-31

    Innovative systems with increased sensitivity and resolution are in great demand to detect diversion and to prevent misuse in support of nuclear materials management for the U.S. fuel cycle. Nuclear fission is the most important multiplicative process involved in non-destructive active interrogation. This process produces the most easily recognizable signature for nuclear materials. In addition to thermal or high-energy neutrons, high-energy gamma rays can also excite a nucleus and cause fission through a process known as photofission. Electron linear accelerators (linacs) are widely used as the interrogating photon sources for inspection methods involving photofission technique. After photofission reactions, prompt signals are much stronger than the delayed signals, but it is difficult to quantify them in practical measurements. Delayed signals are easily distinguishable from the interrogating radiation. Linac-based, advanced inspection techniques utilizing the delayed signals after photofission have been extensively studied for homeland security applications. Previous research also showed that a unique delayed gamma ray energy spectrum exists for each fissionable isotope. In this work, high-energy delayed γ-rays were demonstrated to be signatures for detection, identification, and quantification of special nuclear materials. Such γ-rays were measured in between linac pulses using independent data acquisition systems. A list-mode system was developed to measure low-energy delayed γ-rays after irradiation. Photofission product yields of 238U and 239Pu were determined based on the measured delayed γ-ray spectra. The differential yields of delayed γ-rays were also proven to be able to discriminate nuclear from non-nuclear materials. The measurement outcomes were compared with Monte Carlo simulation results. It was demonstrated that the current available codes have capabilities and limitations in the simulation of photofission process. A two

  12. INL Neutron Interrogation R and D: FY2010 MPACT End of Year Report

    International Nuclear Information System (INIS)

    Chichester, D.L.; Seabury, E.H.; Wharton, J.; Watson, S.M.

    2010-01-01

    Experiments have been carried out to investigate the feasibility and utility of using neutron interrogation and small-scale, portable prompt gamma-ray neutron activation analysis (PGNAA) instruments for assaying uranium for safeguards applications. Prior work has shown the potential of the PGNAA technique for assaying uranium using reactor-based neutron sources and high-yield electronic neutron generators (ENGs). In this project we adapted Idaho National Laboratory's portable isotopic neutron spectroscopy (PINS) PGNAA system for measuring natural-enrichment uranium yellowcake and metallic depleted uranium and highly enriched uranium. This work used 252Cf as well as deuterium-deuterium (DD) and deuterium-tritium (DT) ENGs. For PGNAA measurements a limiting factor when assaying large objects is the detector dead time due to fast-neutron scattering off of the uranium; this limits the maximum useable neutron source strength to O(107) neutrons per second. Under these conditions the low PGNAA reaction cross sections for uranium prohibited the collection of useful uranium PGNAA signatures from either the yellowcake or metallic uranium samples. Measurement of the decay product activation in these materials following irradiation in the PGNAA geometry similarly did not produce useful uranium activation product - fission product signatures. A customized irradiation geometry tailored to optimally thermalize the interrogation neutron source, intended only for generating long-lived activation products - fission products and not intended for PGNAA measurements, might be possible using small scale ENGs but an application need and a modeling simulation exercise would be recommended before advancing to experiments. Neutron interrogation PGNAA using a DT-ENG was found to be a quick and useful qualitative method for detecting the presence of oxygen in natural-enrichment uranium yellowcake. With a low effort of development work it would be reasonable to expect this measurement could be

  13. Active Interrogation using Photofission Technique for Nuclear Materials Control and Accountability

    International Nuclear Information System (INIS)

    Yang, Haori

    2016-01-01

    Innovative systems with increased sensitivity and resolution are in great demand to detect diversion and to prevent misuse in support of nuclear materials management for the U.S. fuel cycle. Nuclear fission is the most important multiplicative process involved in non-destructive active interrogation. This process produces the most easily recognizable signature for nuclear materials. In addition to thermal or high-energy neutrons, high-energy gamma rays can also excite a nucleus and cause fission through a process known as photofission. Electron linear accelerators (linacs) are widely used as the interrogating photon sources for inspection methods involving photofission technique. After photofission reactions, prompt signals are much stronger than the delayed signals, but it is difficult to quantify them in practical measurements. Delayed signals are easily distinguishable from the interrogating radiation. Linac-based, advanced inspection techniques utilizing the delayed signals after photofission have been extensively studied for homeland security applications. Previous research also showed that a unique delayed gamma ray energy spectrum exists for each fissionable isotope. In this work, high-energy delayed γ-rays were demonstrated to be signatures for detection, identification, and quantification of special nuclear materials. Such γ-rays were measured in between linac pulses using independent data acquisition systems. A list-mode system was developed to measure low-energy delayed γ-rays after irradiation. Photofission product yields of 238 U and 239 Pu were determined based on the measured delayed γ-ray spectra. The differential yields of delayed γ-rays were also proven to be able to discriminate nuclear from non-nuclear materials. The measurement outcomes were compared with Monte Carlo simulation results. It was demonstrated that the current available codes have capabilities and limitations in the simulation of photofission process. A two-fold approach was

  14. PARs for combustible gas control in advanced light water reactors

    International Nuclear Information System (INIS)

    Hosler, J.; Sliter, G.

    1997-01-01

    This paper discusses the progress being made in the United States to introduce passive autocatalytic recombiner (PAR) technology as a cost-effective alternative to electric recombiners for controlling combustible gas produced in postulated accidents in both future Advanced Light Water Reactors (ALWRs) and certain U. S. operating nuclear plants. PARs catalytically recombine hydrogen and oxygen, gradually producing heat and water vapor. They have no moving parts and are self-starting and self-feeding, even under relatively cold and wet containment conditions. Buoyancy of the hot gases they create sets up natural convective flow that promotes mixing of combustible gases in a containment. In a non-inerted ALWR containment, two approaches each employing a combination of PARs and igniters are being considered to control hydrogen in design basis and severe accidents. In pre-inerted ALWRs, PARs alone control radiolytic oxygen produced in either accident type. The paper also discusses regulatory feedback regarding these combustible gas control approaches and describes a test program being conducted by the Electric Power Research Institute (EPRI) and Electricite de France (EdF) to supplement the existing PAR test database with performance data under conditions of interest to U.S. plants. Preliminary findings from the EPRI/EdF PAR model test program are included. Successful completion of this test program and confirmatory tests being sponsored by the U. S. NRC are expected to pave the way for use of PARs in ALWRs and operating plants. (author)

  15. Radioactive equilibrium of uranium-bearing ores in some problems of applied geology; Les equilibres radioactifs des menerais uraniferes dans quelques problemes de geologie appliquee

    Energy Technology Data Exchange (ETDEWEB)

    Coulomb, R; Girard, Ph; Goldsztein, M [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1964-07-01

    The state of equilibrium between several nuclides in radioactive relationship is determined with accuracy by the fundamental equations of radioactivity. It can be measured physically and expressed in suitable and internationally adopted units; Equilibrium - disequilibrium of uranium-bearing ores is a fairly complex phenomenon but the problem can be much simplified by well-chosen approximations in various practical field cases. The results of radiometric and radiochemical measurements lead to the interpretation of geochemical anomalies and may be used in the qualitative and quantitative estimation of uranium bearing deposits. (authors) [French] L'etat d'equilibre entre plusieurs radioelements en filiation se definit avec precision par les equations fondamentales de la radioactivite et peut etre determine par des mesures physiques dans des systemes d'unites commodes et internationalement adoptes. Le probleme general equilibre-desequilibre des minerais uraniferes est relativement complexe, mais peut se simplifier largement par des approximations judicieuses dans de nombreux cas particuliers rencontres concretement sur le terrain. Les resultats des mesures radiometriques et radiochimiques permettent l'interpretation des anomalies geochimiques et peuvent servir a l'estimation qualitative et quantitative des gisements de minerais uraniferes. (auteurs)

  16. Coupling Sensing Hardware with Data Interrogation Software for Structural Health Monitoring

    Directory of Open Access Journals (Sweden)

    Charles R. Farrar

    2006-01-01

    Full Text Available The process of implementing a damage detection strategy for aerospace, civil and mechanical engineering infrastructure is referred to as structural health monitoring (SHM. The authors' approach is to address the SHM problem in the context of a statistical pattern recognition paradigm. In this paradigm, the process can be broken down into four parts: (1 Operational Evaluation, (2 Data Acquisition and Cleansing, (3 Feature Extraction and Data Compression, and (4 Statistical Model Development for Feature Discrimination. These processes must be implemented through hardware or software and, in general, some combination of these two approaches will be used. This paper will discuss each portion of the SHM process with particular emphasis on the coupling of a general purpose data interrogation software package for structural health monitoring with a modular wireless sensing and processing platform. More specifically, this paper will address the need to take an integrated hardware/software approach to developing SHM solutions.

  17. Additively Manufactured IN718 Components with Wirelessly Powered and Interrogated Embedded Sensing

    Energy Technology Data Exchange (ETDEWEB)

    Attridge, Paul [United Technologies Research Center, East Hartford, CT (United States); Bajekal, Sanjay [United Technologies Research Center, East Hartford, CT (United States); Klecka, Michael [United Technologies Research Center, East Hartford, CT (United States); Wu, Xin [United Technologies Research Center, East Hartford, CT (United States); Savulak, Steve [United Technologies Research Center, East Hartford, CT (United States); Viens, Dan [United Technologies Research Center, East Hartford, CT (United States); Carey, Michael [United Technologies Research Center, East Hartford, CT (United States); Miano, John [United Technologies Research Center, East Hartford, CT (United States); Rioux, William [United Technologies Research Center, East Hartford, CT (United States); Zacchio, Joseph [United Technologies Research Center, East Hartford, CT (United States); Dunst, Richard [National Energy Technology Lab. (NETL), Pittsburgh, PA, (United States); Straub, Doug [National Energy Technology Lab. (NETL), Pittsburgh, PA, (United States); Mantese, Joseph [United Technologies Research Center, East Hartford, CT (United States)

    2017-07-14

    A methodology is described for embedding commercial-off-the-shelf sensors together with wireless communication and power circuit elements using direct laser metal sintered additively manufactured components. Physics based models of the additive manufacturing processes and sensor/wireless level performance models guided the design and embedment processes. A combination of cold spray deposition and laser engineered net shaping was used to fashion the transmitter/receiving elements and embed the sensors, thereby providing environmental protection and component robustness/survivability for harsh conditions. By design, this complement of analog and digital sensors were wirelessly powered and interrogated using a health and utilization monitoring system; enabling real-time, in situ prognostics and diagnostics.

  18. Cyborgs, desiring-machines, bodies without organs, and Westworld: Interrogating academic writing and scholarly identity

    Directory of Open Access Journals (Sweden)

    Deborah M. Netolicky

    2017-07-01

    Full Text Available This paper fashions a lens through which to view scholarly identity and the experience of academic writing. The lens of inquiry I apply is the metaphor of Season 1 of sci-fi HBO television show Westworld and its characters, especially its cyborg protagonist Dolores. Thrumming like electric currents through this lens of inquiry are Haraway’s theorization of the cyborg, the fictional worlds of science fiction and Wonderland, my own lived experience, and Deleuze and Guattari’s desiring-machines and bodies without organs. I engage in the cyborgic technology of writing in order to playfully explore what it means to be a cyborg academic operating in intersecting machinic worlds. I ask: Can we listen to our internal voices and write our own stories? Can we burn the world clean with our scholarship and the ways in which we interrogate ingrained and expected practices?

  19. Interrogating discourse: the application of Foucault's methodological discussion to specific inquiry.

    Science.gov (United States)

    Fadyl, Joanna K; Nicholls, David A; McPherson, Kathryn M

    2013-09-01

    Discourse analysis following the work of Michel Foucault has become a valuable methodology in the critical analysis of a broad range of topics relating to health. However, it can be a daunting task, in that there seems to be both a huge number of possible approaches to carrying out this type of project, and an abundance of different, often conflicting, opinions about what counts as 'Foucauldian'. This article takes the position that methodological design should be informed by ongoing discussion and applied as appropriate to a particular area of inquiry. The discussion given offers an interpretation and application of Foucault's methodological principles, integrating a reading of Foucault with applications of his work by other authors, showing how this is then applied to interrogate the practice of vocational rehabilitation. It is intended as a contribution to methodological discussion in this area, offering an interpretation of various methodological elements described by Foucault, alongside specific application of these aspects.

  20. Interrogating Key Positions of Size-Reduced TALE Repeats Reveals a Programmable Sensor of 5-Carboxylcytosine.

    Science.gov (United States)

    Maurer, Sara; Giess, Mario; Koch, Oliver; Summerer, Daniel

    2016-12-16

    Transcription-activator-like effector (TALE) proteins consist of concatenated repeats that recognize consecutive canonical nucleobases of DNA via the major groove in a programmable fashion. Since this groove displays unique chemical information for the four human epigenetic cytosine nucleobases, TALE repeats with epigenetic selectivity can be engineered, with potential to establish receptors for the programmable decoding of all human nucleobases. TALE repeats recognize nucleobases via key amino acids in a structurally conserved loop whose backbone is positioned very close to the cytosine 5-carbon. This complicates the engineering of selectivities for large 5-substituents. To interrogate a more promising structural space, we engineered size-reduced repeat loops, performed saturation mutagenesis of key positions, and screened a total of 200 repeat-nucleobase interactions for new selectivities. This provided insight into the structural requirements of TALE repeats for affinity and selectivity, revealed repeats with improved or relaxed selectivity, and resulted in the first selective sensor of 5-carboxylcytosine.

  1. Performance Optimization Design for a High-Speed Weak FBG Interrogation System Based on DFB Laser.

    Science.gov (United States)

    Yao, Yiqiang; Li, Zhengying; Wang, Yiming; Liu, Siqi; Dai, Yutang; Gong, Jianmin; Wang, Lixin

    2017-06-22

    A performance optimization design for a high-speed fiber Bragg grating (FBG) interrogation system based on a high-speed distributed feedback (DFB) swept laser is proposed. A time-division-multiplexing sensor network with identical weak FBGs is constituted to realize high-capacity sensing. In order to further improve the multiplexing capacity, a waveform repairing algorithm is designed to extend the dynamic demodulation range of FBG sensors. It is based on the fact that the spectrum of an FBG keeps stable over a long period of time. Compared with the pre-collected spectra, the distorted spectra waveform are identified and repaired. Experimental results show that all the identical weak FBGs are distinguished and demodulated at the speed of 100 kHz with a linearity of above 0.99, and the range of dynamic demodulation is extended by 40%.

  2. Design of a novel instrument for active neutron interrogation of artillery shells.

    Science.gov (United States)

    Bélanger-Champagne, Camille; Vainionpää, Hannes; Peura, Pauli; Toivonen, Harri; Eerola, Paula; Dendooven, Peter

    2017-01-01

    The most common explosives can be uniquely identified by measuring the elemental H/N ratio with a precision better than 10%. Monte Carlo simulations were used to design two variants of a new prompt gamma neutron activation instrument that can achieve this precision. The instrument features an intense pulsed neutron generator with precise timing. Measuring the hydrogen peak from the target explosive is especially challenging because the instrument itself contains hydrogen, which is needed for neutron moderation and shielding. By iterative design optimization, the fraction of the hydrogen peak counts coming from the explosive under interrogation increased from [Formula: see text]% to [Formula: see text]% (statistical only) for the benchmark design. In the optimized design variants, the hydrogen signal from a high-explosive shell can be measured to a statistics-only precision better than 1% in less than 30 minutes for an average neutron production yield of 109 n/s.

  3. Surface Interrogation Scanning Electrochemical Microscopy for a Photoelectrochemical Reaction: Water Oxidation on a Hematite Surface.

    Science.gov (United States)

    Kim, Jae Young; Ahn, Hyun S; Bard, Allen J

    2018-03-06

    To understand the pathway of a photoelectrochemical (PEC) reaction, quantitative knowledge of reaction intermediates is important. We describe here surface interrogation scanning electrochemical microscopy for this purpose (PEC SI-SECM), where a light pulse to a photoactive semiconductor film at a given potential generates intermediates that are then analyzed by a tip generated titrant at known times after the light pulse. The improvements were demonstrated for photoelectrochemical water oxidation (oxygen evolution) reaction on a hematite surface. The density of photoactive sites, proposed to be Fe 4+ species, on a hematite surface was successfully quantified, and the photoelectrochemical water oxidation reaction dynamics were elucidated by time-dependent redox titration experiments. The new configuration of PEC SI-SECM should find expanded usage to understand and investigate more complicated PEC reactions with other materials.

  4. Nanoscale Plasmonic V-Groove Waveguides for the Interrogation of Single Fluorescent Bacterial Cells.

    Science.gov (United States)

    Lotan, Oren; Bar-David, Jonathan; Smith, Cameron L C; Yagur-Kroll, Sharon; Belkin, Shimshon; Kristensen, Anders; Levy, Uriel

    2017-09-13

    We experimentally demonstrate the interrogation of an individual Escherichia coli cell using a nanoscale plasmonic V-groove waveguide. Several different configurations were studied. The first involved the excitation of the cell in a liquid environment because it flows on top of the waveguide nanocoupler, while the obtained fluorescence is coupled into the waveguide and collected at the other nanocoupler. The other two configurations involved the positioning of the bacterium within the nanoscale waveguide and its excitation in a dry environment either directly from the top or through waveguide modes. This is achieved by taking advantage of the waveguide properties not only for light guiding but also as a mechanical tool for trapping the bacteria within the V-grooves. The obtained results are supported by a set of numerical simulations, shedding more light on the mechanism of excitation. This demonstration paves the way for the construction of an efficient bioplasmonic chip for diverse cell-based sensing applications.

  5. Interrogation of metabolic and oxygen states of tumors with fiber-based luminescence lifetime spectroscopy.

    Science.gov (United States)

    Lukina, Maria; Orlova, Anna; Shirmanova, Marina; Shirokov, Daniil; Pavlikov, Anton; Neubauer, Antje; Studier, Hauke; Becker, Wolfgang; Zagaynova, Elena; Yoshihara, Toshitada; Tobita, Seiji; Shcheslavskiy, Vladislav

    2017-02-15

    The study of metabolic and oxygen states of cells in a tumor in vivo is crucial for understanding of the mechanisms responsible for tumor development and provides background for the relevant tumor's treatment. Here, we show that a specially designed implantable fiber-optic probe provides a promising tool for optical interrogation of metabolic and oxygen states of a tumor in vivo. In our experiments, the excitation light from a ps diode laser source is delivered to the sample through an exchangeable tip via a multimode fiber, and the emission light is transferred to the detector by another multimode fiber. Fluorescence lifetime of a nicotinamid adenine dinucleotide (NAD(P)H) and phosphorescence lifetime of an oxygen sensor based on an iridium (III) complex of enzothienylpyridine (BTPDM1) are explored both in model experiment in solutions and in living mice.

  6. Integrated Si-based nanoplasmonic sensor with phase-sensitive angular interrogation

    Energy Technology Data Exchange (ETDEWEB)

    Patskovsky, Sergiy; Meunier, Michel [Laser Processing and Plasmonics Laboratory, Ecole Polytechnique de Montreal, C. P. 6079, succ. Centre-Ville, Montreal, QC, H3C 3A7 (Canada)

    2013-06-15

    This work is related to the development of an integrated Surface Plasmon Resonance (SPR) sensor on silicon platform. The optical properties of metallic nanogratings fabricated on the semiconductor structure allow direct plasmonic detection in transmission mode. Specially designed angular interrogation method provides a periodic signal with phase dependent on the conditions of surface plasmon excitation. Proposed technique leads to sensitivity better than 10{sup -6} RIU for conventional SPR Kretschmann configuration and was tested on the integrated Si-based nanoplasmonic chip. Developed concept is promising for low-cost mono and multi -sensing applications by portable or stationary platforms. (copyright 2013 by WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  7. The plasticity of early memory reports: social pressure, hypnotizability, compliance, and interrogative suggestibility.

    Science.gov (United States)

    Malinoski, P T; Lynn, S J

    1999-10-01

    Early autobiographical memory reports by adults were very sensitive to social influence in a leading interview. The mean age of initial earliest memory report was 3.7 years. When participants were instructed to close their eyes, visualize, and focus on their 2nd birthday, 59% reported a birthday memory. After repeated probes for earlier memories, 78% of subjects reported memories at or prior to 24 months of age, and 33% reported memories within the first 12 months of age. The mean age of the final earliest memory reported was 1.6 years. Participants rated their memory reports as accurate and did not recant them when given an opportunity. The age of earliest memory reports in the suggestive interview correlated negatively with measures of compliance, hypnotizability, and interrogative suggestibility.

  8. Model of a Plasmonic Phase Interrogation Probe for Optical Sensing of Hemoglobin in Blood Samples

    Science.gov (United States)

    Sharma, Anuj K.

    2015-11-01

    Phase interrogation based surface plasmon resonance (SPR) biosensor is proposed for the determination of Hb concentration. Previous experimental results describing variation of refractive index of human blood with Hb concentration at different wavelengths are considered for design simulations. The biosensor design with silica substrate and gold layer is considered. The sensor's performance is closely analyzed in terms of phase sensitivity and resolution. The influence of operating wavelength on biosensor's performance for Hb measurement is critically investigated, which points to carry out the Hb measurement at a shorter wavelength as phase sensitivity and resolution increase significantly with decrease in wavelength. The results are explained in terms of suitable physical concepts such as radiation damping. Use of contamination-preventing biochemical layer ascertains the stability of measurement with the intended SPR biosensor probe. The simulation results also highlight that the resolution of Hb measurement achievable with the proposed biosensor is much higher compared with several existing methods.

  9. Performance Optimization Design for a High-Speed Weak FBG Interrogation System Based on DFB Laser

    Directory of Open Access Journals (Sweden)

    Yiqiang Yao

    2017-06-01

    Full Text Available A performance optimization design for a high-speed fiber Bragg grating (FBG interrogation system based on a high-speed distributed feedback (DFB swept laser is proposed. A time-division-multiplexing sensor network with identical weak FBGs is constituted to realize high-capacity sensing. In order to further improve the multiplexing capacity, a waveform repairing algorithm is designed to extend the dynamic demodulation range of FBG sensors. It is based on the fact that the spectrum of an FBG keeps stable over a long period of time. Compared with the pre-collected spectra, the distorted spectra waveform are identified and repaired. Experimental results show that all the identical weak FBGs are distinguished and demodulated at the speed of 100 kHz with a linearity of above 0.99, and the range of dynamic demodulation is extended by 40%.

  10. Design of a novel instrument for active neutron interrogation of artillery shells.

    Directory of Open Access Journals (Sweden)

    Camille Bélanger-Champagne

    Full Text Available The most common explosives can be uniquely identified by measuring the elemental H/N ratio with a precision better than 10%. Monte Carlo simulations were used to design two variants of a new prompt gamma neutron activation instrument that can achieve this precision. The instrument features an intense pulsed neutron generator with precise timing. Measuring the hydrogen peak from the target explosive is especially challenging because the instrument itself contains hydrogen, which is needed for neutron moderation and shielding. By iterative design optimization, the fraction of the hydrogen peak counts coming from the explosive under interrogation increased from [Formula: see text]% to [Formula: see text]% (statistical only for the benchmark design. In the optimized design variants, the hydrogen signal from a high-explosive shell can be measured to a statistics-only precision better than 1% in less than 30 minutes for an average neutron production yield of 109 n/s.

  11. Microwave interrogated large core fused silica fiber Michelson interferometer for strain sensing.

    Science.gov (United States)

    Hua, Liwei; Song, Yang; Huang, Jie; Lan, Xinwei; Li, Yanjun; Xiao, Hai

    2015-08-20

    A Michelson-type large core optical fiber sensor has been developed, which is designed based on the optical carrier-based microwave interferometry technique, and fabricated by using two pieces of 200-μm diameter fused silica core fiber as two arms of the Michelson interferometer. The interference fringe pattern caused by the optical path difference of the two arms is interrogated in the microwave domain, where the fringe visibility of 40 dB has easily been obtained. The strain sensing at both room temperature and high temperatures has been demonstrated by using such a sensor. Experimental results show that this sensor has a linear response to the applied strain, and also has relatively low temperature-strain cross talk. The dopant-free quality of the fused silica fiber provides high possibility for the sensor to have promising strain sensing performance in a high temperature environment.

  12. Critically interrogating the fragmentation and weak institutionalization of ‘Communication Studies’ in Europe

    DEFF Research Database (Denmark)

    Phillips, Louise Jane

    robust and dynamic field”, Media Culture & Society, 35(8): 1019-1022. Jørgensen, M. and Phillips, L. (2002). Discourse Analysis as Theory and Method. London: Sage. Olssen, M. and Peters, M. 2005. ‘Neoliberalism, higher education and the knowledge economy: from the free market to knowledge capitalism......This paper will critically interrogate the marginalization of communication studies in the European research and education landscape. Drawing on a discourse theoretical approach (eg Jørgensen and Phillips 2002), it will analyse the marginalization of communication studies in the context of current...... conditions for knowledge production in the “neo-liberal university” and discuss the implications with respect to epistemological and political (im)possibilities and the play of power. The paper will first discuss the marginalization of ‘media and communication studies’ before concentrating...

  13. Recent advances in the prenatal interrogation of the human fetal genome.

    Science.gov (United States)

    Hui, Lisa; Bianchi, Diana W

    2013-02-01

    The amount of genetic and genomic information obtainable from the human fetus during pregnancy is accelerating at an unprecedented rate. Two themes have dominated recent technological advances in prenatal diagnosis: interrogation of the fetal genome in increasingly high resolution and the development of non-invasive methods of fetal testing using cell-free DNA in maternal plasma. These two areas of advancement have now converged with several recent reports of non-invasive assessment of the entire fetal genome from maternal blood. However, technological progress is outpacing the ability of the healthcare providers and patients to incorporate these new tests into existing clinical care, and further complicates many of the economic and ethical dilemmas in prenatal diagnosis. This review summarizes recent work in this field and discusses the integration of these new technologies into the clinic and society. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Using cooperatives ontologies for the customization of hybrid mediator interrogation process

    Directory of Open Access Journals (Sweden)

    Cherrat LOUBNA

    2011-06-01

    Full Text Available The explosion of information sources accessible via the Web created the need for mediation tools between users and heterogeneous information sources on the Web. However, the interface design of these mediators, with taking into account the wide variety of skills and knowledge of users, and the need for them to share their preferences, requires systems able to guide the user through the interrogation process. In this paper, we try to raise this challenge  by proposing, on one hand, the use of a cooperative ontology’s models, which adapt with the evolution of user’s profiles and the dynamic change of integrated sources, and secondly ensure sharing the knowledge between users which will facilitate analysis of information and improve the data quality research process in space  and time.

  15. Bayesian variable selection for post-analytic interrogation of susceptibility loci.

    Science.gov (United States)

    Chen, Siying; Nunez, Sara; Reilly, Muredach P; Foulkes, Andrea S

    2017-06-01

    Understanding the complex interplay among protein coding genes and regulatory elements requires rigorous interrogation with analytic tools designed for discerning the relative contributions of overlapping genomic regions. To this aim, we offer a novel application of Bayesian variable selection (BVS) for classifying genomic class level associations using existing large meta-analysis summary level resources. This approach is applied using the expectation maximization variable selection (EMVS) algorithm to typed and imputed SNPs across 502 protein coding genes (PCGs) and 220 long intergenic non-coding RNAs (lncRNAs) that overlap 45 known loci for coronary artery disease (CAD) using publicly available Global Lipids Gentics Consortium (GLGC) (Teslovich et al., 2010; Willer et al., 2013) meta-analysis summary statistics for low-density lipoprotein cholesterol (LDL-C). The analysis reveals 33 PCGs and three lncRNAs across 11 loci with >50% posterior probabilities for inclusion in an additive model of association. The findings are consistent with previous reports, while providing some new insight into the architecture of LDL-cholesterol to be investigated further. As genomic taxonomies continue to evolve, additional classes such as enhancer elements and splicing regions, can easily be layered into the proposed analysis framework. Moreover, application of this approach to alternative publicly available meta-analysis resources, or more generally as a post-analytic strategy to further interrogate regions that are identified through single point analysis, is straightforward. All coding examples are implemented in R version 3.2.1 and provided as supplemental material. © 2016, The International Biometric Society.

  16. uPAR as anti-cancer target

    DEFF Research Database (Denmark)

    Lund, Ida K; Illemann, Martin; Thurison, Tine

    2011-01-01

    , and a potential diagnostic and predictive impact of the different uPAR forms has been reported. Hence, pericellular proteolysis seems to be a suitable target for anti-cancer therapy and numerous approaches have been pursued. Targeting of this process may be achieved by preventing the binding of uPA to u...... using mouse monoclonal antibodies (mAbs) against mouse uPA or uPAR. These reagents will target uPA and uPAR in both stromal cells and cancer cells, and their therapeutic potential can now be assessed in syngenic mouse cancer models....

  17. Limnological database for Par Pond: 1959 to 1980

    International Nuclear Information System (INIS)

    Tilly, L.J.

    1981-03-01

    A limnological database for Par Pond, a cooling reservoir for hot reactor effluent water at the Savannah River Plant, is described. The data are derived from a combination of research and monitoring efforts on Par Pond since 1959. The approximately 24,000-byte database provides water quality, primary productivity, and flow data from a number of different stations, depths, and times during the 22-year history of the Par Pond impoundment. The data have been organized to permit an interpretation of the effects of twenty years of cooling system operations on the structure and function of an aquatic ecosystem

  18. Protease-activated receptor (PAR2, but not PAR1, is involved in collateral formation and anti-inflammatory monocyte polarization in a mouse hind limb ischemia model.

    Directory of Open Access Journals (Sweden)

    Lisa G van den Hengel

    Full Text Available AIMS: In collateral development (i.e. arteriogenesis, mononuclear cells are important and exist as a heterogeneous population consisting of pro-inflammatory and anti-inflammatory/repair-associated cells. Protease-activated receptor (PAR1 and PAR2 are G-protein-coupled receptors that are both expressed by mononuclear cells and are involved in pro-inflammatory reactions, while PAR2 also plays a role in repair-associated responses. Here, we investigated the physiological role of PAR1 and PAR2 in arteriogenesis in a murine hind limb ischemia model. METHODS AND RESULTS: PAR1-deficient (PAR1-/-, PAR2-deficient (PAR2-/- and wild-type (WT mice underwent femoral artery ligation. Laser Doppler measurements revealed reduced post-ischemic blood flow recovery in PAR2-/- hind limbs when compared to WT, while PAR1-/- mice were not affected. Upon ischemia, reduced numbers of smooth muscle actin (SMA-positive collaterals and CD31-positive capillaries were found in PAR2-/- mice when compared to WT mice, whereas these parameters in PAR1-/- mice did not differ from WT mice. The pool of circulating repair-associated (Ly6C-low monocytes and the number of repair-associated (CD206-positive macrophages surrounding collaterals in the hind limbs were increased in WT and PAR1-/- mice, but unaffected in PAR2-/- mice. The number of repair-associated macrophages in PAR2-/- hind limbs correlated with CD11b- and CD115-expression on the circulating monocytes in these animals, suggesting that monocyte extravasation and M-CSF-dependent differentiation into repair-associated cells are hampered. CONCLUSION: PAR2, but not PAR1, is involved in arteriogenesis and promotes the repair-associated response in ischemic tissues. Therefore, PAR2 potentially forms a new pro-arteriogenic target in coronary artery disease (CAD patients.

  19. Novel role for proteinase-activated receptor 2 (PAR2) in membrane trafficking of proteinase-activated receptor 4 (PAR4).

    Science.gov (United States)

    Cunningham, Margaret R; McIntosh, Kathryn A; Pediani, John D; Robben, Joris; Cooke, Alexandra E; Nilsson, Mary; Gould, Gwyn W; Mundell, Stuart; Milligan, Graeme; Plevin, Robin

    2012-05-11

    Proteinase-activated receptors 4 (PAR(4)) is a class A G protein-coupled receptor (GPCR) recognized through the ability of serine proteases such as thrombin and trypsin to mediate receptor activation. Due to the irreversible nature of activation, a fresh supply of receptor is required to be mobilized to the cell surface for responsiveness to agonist to be sustained. Unlike other PAR subtypes, the mechanisms regulating receptor trafficking of PAR(4) remain unknown. Here, we report novel features of the intracellular trafficking of PAR(4) to the plasma membrane. PAR(4) was poorly expressed at the plasma membrane and largely retained in the endoplasmic reticulum (ER) in a complex with the COPI protein subunit β-COP1. Analysis of the PAR(4) protein sequence identified an arginine-based (RXR) ER retention sequence located within intracellular loop-2 (R(183)AR → A(183)AA), mutation of which allowed efficient membrane delivery of PAR(4). Interestingly, co-expression with PAR(2) facilitated plasma membrane delivery of PAR(4), an effect produced through disruption of β-COP1 binding and facilitation of interaction with the chaperone protein 14-3-3ζ. Intermolecular FRET studies confirmed heterodimerization between PAR(2) and PAR(4). PAR(2) also enhanced glycosylation of PAR(4) and activation of PAR(4) signaling. Our results identify a novel regulatory role for PAR(2) in the anterograde traffic of PAR(4). PAR(2) was shown to both facilitate and abrogate protein interactions with PAR(4), impacting upon receptor localization and cell signal transduction. This work is likely to impact markedly upon the understanding of the receptor pharmacology of PAR(4) in normal physiology and disease.

  20. The processing and management of wastes from atomic reactors; Nouvelles installations industrielles du C.E.A. pour le traitement des dechets radioactifs liquides et solides

    Energy Technology Data Exchange (ETDEWEB)

    Cerre, P; Mestre, E; Bourdrez, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    The policy concerning radioactive wastes studied by all Atomic Centres has led to various procedures which, while apparently numerous, come under a few standard headings. Whether the wastes are in the liquid or solid state their management depends on their physical and chemical nature. The procedure adopted is governed by three general principles: - determination of the most economical means possible of storage and processing by volume reduction; - conversion to a solid compact form; - complete acceptance of the accepted standards at all places and all times. In this communication all the standard solutions adopted and used by the various Centres of the Commissariat a l'Energie Atomique will be examined bearing in mind the preceding remarks. Particular mention will be made of the following: - For liquids, physical, chemical and physico-chemical processing - For solids, decontamination, volume reduction and long-term conditioning techniques. The different procedures for collecting and storing solid wastes before and after processing are also discussed. The paper ends with a brief review of the studies, both technical and economic, being pursued on this subject. (authors) [French] La gestion des dechets etudies par tous les Centres Atomiques a donne lieu a des solutions qui - bien que nombreuses en apparence - se ramenent a quelques solutions types, peu nombreuses. Qu'il s'agisse de dechets solides ou liquides, la nature physique et chimique des dechets conditionne leur mode de gestion. Celle-ci procede de trois principes generaux: - recherche du mode de stockage et de traitement aussi economique que possible par reduction de volume; - mise sous forme compacte solide; - garantie du respect des normes en tous lieux et en tous temps. Dans cette communication, nous examinons toutes les solutions types, compte tenu des remarques precedentes, qui ont ete adoptees et sont utilisees par les differents Centres du Commissariat a l'Energie Atomique. Nous rappelons en