WorldWideScience

Sample records for radiator test results

  1. Radiation Testing on State-of-the-Art CMOS: Challenges, Plans, and Preliminary Results

    Science.gov (United States)

    LaBel, Kenneth A.; Cohn, Lewis M.

    2009-01-01

    At GOMAC 2007 and 2008, we discussed a variety of challenges for radiation testing of modern semiconductor devices and technologies [1, 2]. In this presentation, we provide more specific details in this on-going investigation focusing on out-of-the-box lessons observed for providing radiation effects assurances as well as preliminary test results.

  2. Cone Penetrometer Load Cell Temperature and Radiation Testing Results

    Energy Technology Data Exchange (ETDEWEB)

    Follett, Jordan R.

    2013-08-28

    This report summarizes testing activities performed at the Pacific Northwest National Laboratory to verify the cone penetrometer load cell can withstand the tank conditions present in 241-AN-101 and 241-AN-106. The tests demonstrated the load cell device will operate under the elevated temperature and radiation levels expected to be encountered during tank farm deployment of the device.

  3. Mortality in Zarinsk area of Altai Krai as a territory exposed to radiation as a result of nuclear tests at the Semipalatinsk test site

    OpenAIRE

    Kolyado I.; Plugin S.

    2017-01-01

    In Altai krai, there exists a regional segment of the National Radiation Epidemiological Register. The most numerous contingent are victims of nuclear tests at the Semipalatinsk testing site. The new method of calculation of cumulative total effective whole-body radiation dose in patients exposed to radiation as a result of nuclear testing at the Semipalatinsk test site allowed expanding this contingent, to a large extent - due to the inhabitants of Zarinsk area of Altai Krai. The given artic...

  4. Test-beam Results from a RICH Detector Prototype Using Aerogel Radiator and Pixel Hybrid Photon Detectors

    CERN Document Server

    Aglieri-Rinella, G; Van Lysebetten, A; Piedigrossi, D; Wyllie, K; Bellunato, T F; Calvi, M; Matteuzzi, C; Musy, M; Perego, D L; Somerville, L P; Newby, C; Easo, S; Wotton, S

    2006-01-01

    A test-beam study was performed at CERN with a Ring Imaging Cherenkov (RICH) prototype using three pixel Hybrid Photon Detectors. Results on the photon yield and Cherenkov angle resolution are presented here, for the Aerogel radiator and also for reference runs taken with Nitrogen radiator.

  5. Results of radiation tests at cryogenic temperature on some selected organic materials for the LHC

    International Nuclear Information System (INIS)

    Schoenbacher, H.; Szeless, B.; Tavlet, M.; Humer, K.; Weber, H.W.

    1996-01-01

    Future multi-TeV particle accelerators like the CERN Large Hadron Collider (LHC) will use superconducting magnets where organic materials will be exposed to high radiation levels at temperatures as low as 2 K. A representative selection of organic materials comprising insulating films, cable insulations, and epoxy-type impregnated resins were exposed to neutron and gamma radiation of a nuclear reactor. Depending on the type of materials, the integrated radiation doses varied between 180 kGy and 155 MGy. During irradiation, the samples were kept close to the boiling temperature of liquid nitrogen i.e. ∼ 80 K and thereafter stored in liquid nitrogen and transferred at the same temperature into the testing device for measurement of tensile and flexural strength. Tests were carried out on the same materials at similar dose rates at room temperature, and the results were compared with those obtained at cryogenic temperature. They show that, within the selected dose range, a number of organic materials are suitable for use in the radiation field of the LHC at cryogenic temperature. (orig.)

  6. Results of radiation tests at cryogenic temperature on some selected organic materials for the LHC

    International Nuclear Information System (INIS)

    Tavlet, M.; Schoenbacher, H.

    1999-01-01

    In the near future, particle accelerators and detectors as well as fusion reactors will operate at cryogenic temperatures. At temperatures as low as 2 K, the organic materials used for the insulation of the superconducting magnets and cables will be exposed to high radiation levels. In this work, a representative selection of organic materials comprising insulating films, cable insulations and epoxy-type-impregnated resins were exposed to neutron and gamma radiation of nuclear reactors, both at ambient and cryogenic temperatures, and were subsequently mechanically tested. The results show that the radiation degradation is never worse in a cryogenic fluid than it is in usual ambient conditions. (author)

  7. Guidelines for testing sealed radiation sources

    International Nuclear Information System (INIS)

    1989-01-01

    These guidelines are based on article 16(1) of the Ordinance on the Implementation of Atomic Safety and Radiation Protection dated 11 October 1984 (VOAS), in connection with article 36 of the Executory Provision to the VOAS, of 11 October 1984. They apply to the testing of sealed sources to verify their intactness, tightness and non-contamination as well as observance of their fixed service time. The type, scope and intervals of testing as well as the evaluation of test results are determined. These guidelines also apply to the testing of radiation sources forming part of radiation equipment, unless otherwise provided for in the type license or permit. These guidelines enter into force on 1 January 1990

  8. Radiation impact on the characteristics of optical glasses test results on a selected set of materials

    Science.gov (United States)

    Fruit, Michel; Gussarov, Andrei; Berghmans, Francis; Doyle, Dominic; Ulbrich, Gerd

    2017-11-01

    It is well known within the Space optics community that radiation may significantly affect transmittance of glasses. To overcome this drawback, glass manufacturers have developed Cerium doped counterparts of classical glasses. This doped glasses display much less transmittance sensitivity to radiation. Still, the impact of radiation on refractive index is less known and may affect indifferently classical or Cerium doped glasses. ESTEC has initialised an R&D program with the aim of establishing a comprehensive data base gathering radiation sensitivity data, called Dose coefficients, for all the glass optical parameters (transmittance / refractive index / compaction……). The first part of this study, to define the methodology for such a data base, is run by ASTRIUM SAS in co-operation with SCK CEN. This covers theoretical studies associated to testing of a selected set of classical and "radiation hardened" glasses. It is proposed here to present first the theoretical backgrounds of this study and then to give results which have been obtained so far.

  9. Recent results on CVD diamond radiation sensors

    Science.gov (United States)

    Weilhammer, P.; Adam, W.; Bauer, C.; Berdermann, E.; Bogani, F.; Borchi, E.; Bruzzi, M.; Colledani, C.; Conway, J.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; v. d. Eijk, R.; van Eijk, B.; Fallou, A.; Fish, D.; Fried, M.; Gan, K. K.; Gheeraert, E.; Grigoriev, E.; Hallewell, G.; Hall-Wilton, R.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Knopfle, K. T.; Krammer, M.; Manfredi, P. F.; Meier, D.; LeNormand; Pan, L. S.; Pernegger, H.; Pernicka, M.; Plano, R.; Re, V.; Riester, J. L.; Roe, S.; Roff; Rudge, A.; Schieber, M.; Schnetzer, S.; Sciortino, S.; Speziali, V.; Stelzer, H.; Stone, R.; Tapper, R. J.; Tesarek, R.; Thomson, G. B.; Trawick, M.; Trischuk, W.; Turchetta, R.; RD 42 Collaboration

    1998-02-01

    CVD diamond radiation sensors are being developed for possible use in trackers in the LHC experiments. The diamond promises to be radiation hard well beyond particle fluences that can be tolerated by Si sensors. Recent results from the RD 42 collaboration on charge collection distance and on radiation hardness of CVD diamond samples will be reported. Measurements with diamond tracking devices, both strip detectors and pixel detectors, will be discussed. Results from beam tests using a diamond strip detector which was read out with fast, 25 ns shaping time, radiation-hard pipeline electronics will be presented.

  10. Radiation monitoring data on the power-up test of HTTR. Results up to 20 MW operation

    International Nuclear Information System (INIS)

    Ashikagaya, Yoshinobu; Nakazawa, Takashi; Yoshino, Toshiaki; Yasu, Katsuji

    2002-01-01

    The High Temperature Engineering Test Reactor (HTTR) have completed the Power-up test of 9 MW (the single and parallel loaded operation) in the rated operation mode. After that the Power-up test in the rated operation mode and the high-temperature test operation mode with a thermal output of 20 MW (the single and parallel loaded operation) were performed between January 16, 2001 and June 10, 2001. This report describes the radiation monitoring data carried out during the HTTR Power-up test in the rated operation mode and the high-temperature test operation mode with a thermal output of 20 MW. The followings were concluded from these radiation monitoring data. The monitoring of radioactive gaseous effluents and the radiation protection for the works will be easy to do and the exposure dose of the workers will be kept the low level. (author)

  11. Radiation consequences of the nuclear tests on the Semipalatinsk test site

    International Nuclear Information System (INIS)

    Logachev, V.A.; Logacheva, L.A.

    2001-01-01

    In the paper the results of retrospective evaluation for radiation situation and radiation doses of population in the zones of the Semipalatinsk test site activity influence are presented. For the measurements the data obtained during analysis, study and summarizing of the archival materials including information on nuclear tests on this site and results of radiation surveys, those were carried out after each test were used. The information testifying most substantial environment contamination taking place after four surface explosions (29.08.1949, 24.09.1951, 12.08.1953, 24.08.1956) is presented as well. After these dose-forming explosions the irradiation doses of the population inhabiting out the regime zone have been exceeded the maximum permissible levels. Results of analysis of archival materials were used for assessment of doses of internal and external irradiation of residents of inhabited points situated on the both the territory of the Republic of Kazakhstan - mainly close to the test site - and the territories of a number of regions of the Russian Federation are locating on the little distance from the tests site

  12. Test on radiation-withstanding properties of sensors

    International Nuclear Information System (INIS)

    Yagi, Hideyuki; Kakuta, Tsunemi; Ara, Katsuyuki

    1986-01-01

    In order to use for the remote operation system or in-line measuring system in the facilities handling radioactive substances, the development of the sensors having strengthened radiation-withstanding performance has been advanced. As a part of it, efforts have been exerted to phenomenologically grasp the radiation effect on various sensors and their materials, and to acquire the basic data. Irradiation test was carried out on solid image pick-up elements, optical parts eddy current sensors, pressure sensitive rubber, photo-electric proximity sensors and others, and the knowledge on their deterioration was obtained. Besides, the sensors and video-cameras having improved radiation-withstanding performance were made for trial, and the performance was tested. The interim report on these test results is made. By a series of the irradiation tests reported here, the basic data required for giving the guideline to the development of radiation withstanding sensors were able to be obtained. But in the present irradiation test, the number of specimens was too small to assure the radiation withstanding performance. In order to improve further the radiation withstanding performance of these sensors, it is necessary to carry out the irradiation test on such elements as condensers, diodes and ICs to accumulate the basic data. (Kako, I.)

  13. Lap Shear Testing of Candidate Radiator Panel Adhesives

    Science.gov (United States)

    Ellis, David; Briggs, Maxwell; McGowan, Randy

    2013-01-01

    During testing of a subscale radiator section used to develop manufacturing techniques for a full-scale radiator panel, the adhesive bonds between the titanium heat pipes and the aluminum face sheets failed during installation and operation. Analysis revealed that the thermal expansion mismatch between the two metals resulted in relatively large shear stresses being developed even when operating the radiator at moderate temperatures. Lap shear testing of the adhesive used in the original joints demonstrated that the two-part epoxy adhesive fell far short of the strength required. A literature review resulted in several candidate adhesives being selected for lap shear joint testing at room temperature and 398 K, the nominal radiator operating temperature. The results showed that two-part epoxies cured at room and elevated temperatures generally did not perform well. Epoxy film adhesives cured at elevated temperatures, on the other hand, did very well with most being sufficiently strong to cause yielding in the titanium sheet used for the joints. The use of an epoxy primer generally improved the strength of the joint. Based upon these results, a new adhesive was selected for the second subscale radiator section.

  14. Nevada Test Site Radiation Protection Program

    Energy Technology Data Exchange (ETDEWEB)

    Radiological Control Managers' Council, Nevada Test Site

    2007-08-09

    Title 10 Code of Federal Regulations (CFR) 835, 'Occupational Radiation Protection', establishes radiation protection standards, limits, and program requirements for protecting individuals from ionizing radiation resulting from the conduct of U.S. Department of Energy (DOE) activities. 10 CFR 835.101(a) mandates that DOE activities be conducted in compliance with a documented Radiation Protection Program (RPP) as approved by DOE. This document promulgates the RPP for the Nevada Test Site (NTS), related (onsite or offsite) DOE National Nuclear Security Administration Nevada Site Office (NNSA/NSO) operations, and environmental restoration offsite projects.

  15. Estimation of radiation dose received by the radiation workers during radiographic testing

    International Nuclear Information System (INIS)

    Mohammed, N. A. H. O.

    2013-08-01

    This study was conducted primarily to evaluate occupational radiation dose in industrial radiography during radiographic testing at Balil-Hadida, with the aim of building up baseline data on radiation exposure in the industrial radiography practice in Sudan. Dose measurements during radiographic testing were performed and compared with IAEA reference dose. In this research the doses measured by using hand held radiation survey meter and personal monitoring dosimeter. The results showed that radiation doses ranged between minimum (0.448 mSv/ 3 month) , and maximum (1.838 mSv / 3 month), with an average value (0.778 mSv/ 3 month), and the standard deviation 0.292 for the workers used gamma mat camera. The analysis of data showed that the radiation dose for all radiation worker are receives less than annual limit for exposed workers 20 mSv/ year and compare with other study found that the dose received while body doses ranging from 0.1 to 9.4 mSv/ year, work area design in all the radiography site followed the three standard rules namely putting radiation signs, reducing access to control area and making of boundaries. Thus the accidents arising from design faults not likely to occur at these site. Results suggest that adequate fundamental training of radiation workers in general radiography prior to industrial radiography work will further improve the standard of personnel radiation protection. (Author)

  16. Six-Tube Freezable Radiator Testing and Model Correlation

    Science.gov (United States)

    Lilibridge, Sean T.; Navarro, Moses

    2012-01-01

    Freezable Radiators offer an attractive solution to the issue of thermal control system scalability. As thermal environments change, a freezable radiator will effectively scale the total heat rejection it is capable of as a function of the thermal environment and flow rate through the radiator. Scalable thermal control systems are a critical technology for spacecraft that will endure missions with widely varying thermal requirements. These changing requirements are a result of the spacecraft?s surroundings and because of different thermal loads rejected during different mission phases. However, freezing and thawing (recov ering) a freezable radiator is a process that has historically proven very difficult to predict through modeling, resulting in highly inaccurate predictions of recovery time. These predictions are a critical step in gaining the capability to quickly design and produce optimized freezable radiators for a range of mission requirements. This paper builds upon previous efforts made to correlate a Thermal Desktop(TM) model with empirical testing data from two test articles, with additional model modifications and empirical data from a sub-component radiator for a full scale design. Two working fluids were tested: MultiTherm WB-58 and a 50-50 mixture of DI water and Amsoil ANT.

  17. Statistical properties of SASE FEL radiation: experimental results from the VUV FEL at the TESLA test facility at DESY

    International Nuclear Information System (INIS)

    Yurkov, M.V.

    2002-01-01

    This paper presents an experimental study of the statistical properties of the radiation from a SASE FEL. The experiments were performed at the TESLA Test Facility VUV SASE FEL at DESY operating in a high-gain linear regime with a gain of about 10 6 . It is shown that fluctuations of the output radiation energy follows a gamma-distribution. We also measured for the first time the probability distribution of SASE radiation energy after a narrow-band monochromator. The experimental results are in good agreement with theoretical predictions, the energy fluctuations after the monochromator follow a negative exponential distribution

  18. Report on the Radiation Effects Testing of the Infrared and Optical Transition Radiation Camera Systems

    Energy Technology Data Exchange (ETDEWEB)

    Holloway, Michael Andrew [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-04-20

    Presented in this report are the results tests performed at Argonne National Lab in collaboration with Los Alamos National Lab to assess the reliability of the critical 99Mo production facility beam monitoring diagnostics. The main components of the beam monitoring systems are two cameras that will be exposed to radiation during accelerator operation. The purpose of this test is to assess the reliability of the cameras and related optical components when exposed to operational radiation levels. Both X-ray and neutron radiation could potentially damage camera electronics as well as the optical components such as lenses and windows. This report covers results of the testing of component reliability when exposed to X-ray radiation. With the information from this study we provide recommendations for implementing protective measures for the camera systems in order to minimize the occurrence of radiation-induced failure within a ten month production run cycle.

  19. Test results of the experimental laser device for potato tubers radiation treatment

    International Nuclear Information System (INIS)

    Anufrik, S.S.; Korzun, O.S.

    2007-01-01

    Results of 3 year investigation of the influence of the presowing low intensity laser radiation treatment of potato (Solanum tuberosum L.) tubers with the help of laser device with various spectral composition and exposition on plant growth, development and productivity and potato tubers quality and starch content in the conditions of the Republic of Belarus were presented. Presowing tubers treatment of potato cultivars Sante, Yavar and Arkhideya was realized by He-Ne, Ar-, Cu (in course of 3 and 5 minutes) and CO2 (in course of 5 seconds) lasers. Research results have shown that presowing treatment with CO2 laser promoted the higher (on 1,7-6,6%) potato germination capacity in comparison with the control variant without radiation treatment. Height of potato plants of Sante variety after radiation treatment fell behind the control ones. Haulm quantity per one plant and yield quality did not depend on radiation treatment Treatment with CO2 laser exercised the stimulatory action on productivity of Sante variety without changing the starch content in tubers. Tuber weight increased up to 0,4 kg (0,2 kg in the control variant). Similar effect for Arkhideya and Yavar varieties was obtained after Cu-laser treatment in course of 5 minutes. Radiation treatment with He-Ne laser caused the increased starch accumulation (on 0,4-0,6% in comparison with the control variant) in potato tubers of all studied varieties

  20. Compilation of radiation damage test data. Pt. 3

    International Nuclear Information System (INIS)

    Beynel, P.; Maier, P.; Schoenbacher, H.

    1982-01-01

    This handbook gives the results of radiation damage tests on various engineering materials and components intended for installation in radiation areas of the CERN high-energy particle accelerators. It complements two previous volumes covering organic cable-insulating materials and thermoplastic and thermosetting resins. The irradiation have been carried out at various radiation sources and the results of the different tests are reported, sometimes illustrated by tables and graphs to show the variation of the measured property with absorbed radiation dose. For each entry, an appreciation of the radiation resistance is given, based on measurement data, indicating the range of damage (moderate to severe) for doses from 10 to 10 8 Gy. Also included are tables, selected from published reports, of general relative radiation effects for several groups of materials, to which there are systematic cross-references in the alphabetical part. This third and last volume contains cross-references to all the materials presented up to now, so that it can be used as a guide to the three volumes. (orig.)

  1. Ionizing radiation test results for an automotive microcontroller on board the Schiaparelli Mars lander

    Science.gov (United States)

    Tapani Nikkanen, Timo; Hieta, Maria; Schmidt, Walter; Genzer, Maria; Haukka, Harri; Harri, Ari-Matti

    2016-04-01

    The Finnish Meteorological Institute (FMI) has delivered a pressure and a humidity instrument for the ESA ExoMars 2016 Schiaparelli lander mission. Schiaparelli is scheduled to launch towards Mars with the Trace Gas Orbiter on 14th of March 2016. The DREAMS-P (pressure) and DREAMS-H (Humidity) instruments are operated utilizing a novel FMI instrument controller design based on a commercial automotive microcontroller (MCU). A custom qualification program was implemented to qualify the MCU for the relevant launch, cruise and surface operations environment of a Mars lander. Resilience to ionizing radiation is one of the most critical requirements for a digital component operated in space or at planetary bodies. Thus, the expected Total Ionizing Dose accumulated by the MCU was determined and a sample of these components was exposed to a Co-60 gamma radiation source. Part of the samples was powered during the radiation exposure to include the effect of electrical biasing. All of the samples were verified to withstand the expected total ionizing dose with margin. The irradiated test samples were then radiated until failure to determine their ultimate TID.

  2. Recent results on the development of radiation-hard diamond detectors

    CERN Document Server

    Conway, J S; Bauer, C; Berdermann, E; Bergonzo, P; Bogani, F; Borchi, E; Brambilla, A; Bruzzi, Mara; Colledani, C; Dabrowski, W; Da Graca, J; Delpierre, P A; Deneuville, A; Dulinski, W; van Eijk, B; Fallou, A; Fizzotti, F; Foulon, F; Friedl, M; Gan, K K; Gheeraert, E; Grigoriev, E; Hallewell, G D; Hall-Wilton, R; Han, S; Hartjes, F G; Hrubec, Josef; Husson, D; Jamieson, D; Kagan, H; Kania, D R; Kaplon, J; Karl, C; Kass, R; Knöpfle, K T; Krammer, Manfred; Lo Giudice, A; Lü, R; Manfredi, P F; Manfredotti, C; Marshall, R D; Meier, D; Mishina, M; Oh, A; Pan, L S; Palmieri, V G; Pernicka, Manfred; Peitz, A; Pirollo, S; Plano, R; Polesello, P; Prawer, S; Pretzl, Klaus P; Procario, M; Re, V; Riester, J L; Roe, S; Roff, D G; Rudge, A; Russ, J; Schnetzer, S; Sciortino, S; Somalwar, S V; Speziali, V; Stelzer, H; Stone, R; Suter, B; Tapper, R J; Tesarek, R; Thomson, G B; Trawick, M; Trischuk, W; Vittone, E; Walsh, A M; Wedenig, R; Weilhammer, Peter; White, C; Ziock, H J; Zöller, M

    1999-01-01

    Charged particle detectors made from chemical vapor deposition (CVD) diamond have radiation hardness greatly exceeding that of silicon- based detectors. The CERN-based RD42 Collaboration has developed and tested CVD diamond microstrip and pixel detectors with an eye to their application in the intense radiation environment near the interaction region of hadron colliders. This paper presents recent results from tests of these detectors. (4 refs).

  3. Radiation damage testing at the SSC [Superconducting Super Collider

    International Nuclear Information System (INIS)

    Chinowsky, W.; Thun, R.

    1990-06-01

    A Task Force on Radiation Damage Testing met at the SSC Laboratory on March 5--6, 1990. This Task Force was asked to assess the availability of appropriate facilities for radiation damage tests of SSC detector materials and components. The Task Force was also instructed to review the techniques and standards for conducting such tests. Semiconductors were considered separately from other detector materials. Radiation damage test of electronic devices generally require exposures to both ionizing radiation and neutrons, whereas non-electric components such as plastic scintillating materials, adhesives, cable insulation, and other organic polymers are adequately tested with ionizing radiation only. Test standards are discussed with respect to irradiation techniques, environmental factors, dosimetry, and mechanisms whereby various materials are damaged. It is emphasized that radiation sources should be chosen to duplicate as much as possible the expected SSC environment and that the effects from ionizing particles and from neutrons be investigated separately. Radiation damage tests at reactors must be designed with particular care complex spectra of neutrons and gamma rays are produced at such facilities. It is also essential to investigate dose-rate effects since they are known to be important in many cases. The required irradiations may last several months and are most easily carried out with dedicated radioactive sources. Environmental factors such as the presence of oxygen when testing plastic scintillators, or temperature when measuring semiconductor annealing effects, must also be taken into account. The importance of reliable dosimetry is stressed and suitable references cited. Finally, it is noted that an understanding of the mechanisms for radiation damage in semiconductor and other materials is important in planning irradiations and evaluating results

  4. Radiation resistance of elastomeric O-rings in mixed neutron and gamma fields: Testing methodology and experimental results

    Science.gov (United States)

    Zenoni, A.; Bignotti, F.; Donzella, A.; Donzella, G.; Ferrari, M.; Pandini, S.; Andrighetto, A.; Ballan, M.; Corradetti, S.; Manzolaro, M.; Monetti, A.; Rossignoli, M.; Scarpa, D.; Alloni, D.; Prata, M.; Salvini, A.; Zelaschi, F.

    2017-11-01

    Materials and components employed in the presence of intense neutron and gamma fields are expected to absorb high dose levels that may induce deep modifications of their physical and mechanical properties, possibly causing loss of their function. A protocol for irradiating elastomeric materials in reactor mixed neutron and gamma fields and for testing the evolution of their main mechanical and physical properties with absorbed dose has been developed. Four elastomeric compounds used for vacuum O-rings, one fluoroelastomer polymer (FPM) based and three ethylene propylene diene monomer rubber (EPDM) based, presently available on the market have been selected for the test. One EPDM is rated as radiation resistant in gamma fields, while the other elastomers are general purpose products. Particular care has been devoted to dosimetry calculations, since absorbed dose in neutron fields, unlike pure gamma fields, is strongly dependent on the material composition and, in particular, on the hydrogen content. The products have been tested up to about 2 MGy absorbed dose. The FPM based elastomer, in spite of its lower dose absorption in fast neutron fields, features the largest variations of properties, with a dramatic increase in stiffness and brittleness. Out of the three EPDM based compounds, one shows large and rapid changes in the main mechanical properties, whereas the other two feature more stable behaviors. The performance of the EPDM rated as radiation resistant in pure gamma fields does not appear significantly better than that of the standard product. The predictive capability of the accelerated irradiation tests performed as well as the applicable concepts of threshold of radiation damage is discussed in view of the use of the examined products in the selective production of exotic species facility, now under construction at the Legnaro National Laboratories of the Italian Istituto Nazionale di Fisica Nucleare. It results that a careful account of dose rate effects

  5. Testing of ionizing radiation applicability in storing vegetables and fruit

    International Nuclear Information System (INIS)

    Salkova, Z.

    1980-01-01

    The results are briefly summarized of experimental testing the radiation inhibition of onion, garlic and potatoes germination. The results achieved in studying radiation pasteurization of soft fruit are also discussed. The results are evaluated especially from the standpoint of germination inhibition, reducing material losses, phytopathogenic microbiota suppression and storage extension of vegetables and fruit. The factors are analyzed affecting the final results and the conditions are examined of testing pilot-plant radurization techniques for onion and garlic. (author)

  6. Testing of ionizing radiation applicability in storing vegetables and fruit

    Energy Technology Data Exchange (ETDEWEB)

    Salkova, Z.

    1980-01-01

    The results are briefly summarized of experimental testing the radiation inhibition of onion, garlic and potatoes germination. The results achieved in studying radiation pasteurization of soft fruit are also discussed. The results are evaluated especially from the standpoint of germination inhibition, reducing material losses, phytopathogenic microbiota suppression and storage extension of vegetables and fruit. The factors are analyzed affecting the final results and the conditions are examined of testing pilot-plant radurization techniques for onion and garlic.

  7. Radiation Requirements and Testing of Cryogenic Thermometers for the Ilc

    Science.gov (United States)

    Barnett, T.; Filippov, Yu. P.; Filippova, E. Yu.; Mokhov, N. V.; Nakao, N.; Klebaner, A. L.; Korenev, S. A.; Theilacker, J. C.; Trenikhina, J.; Vaziri, K.

    2008-03-01

    Large quantity of cryogenic temperature sensors will be used for operation of the International Linear Collider (ILC). Most of them will be subject to high radiation doses during the accelerator lifetime. Understanding of particle energy spectra, accumulated radiation dose in thermometers and its impact on performance are vital in establishing technical specification of cryogenic thermometry for the ILC. Realistic MARS15 computer simulations were performed to understand the ILC radiation environment. Simulation results were used to establish radiation dose requirements for commercially available cryogenic thermometers. Two types of thermometers, Cernox® and TVO, were calibrated prior to irradiation using different technique. The sensors were subjected then to up to 200 kGy electron beam irradiation with kinetic energy of 5 MeV, a representative of the situation at the ILC operation. A post-irradiation behavior of the sensors was studied. The paper describes the MARS15 model, simulation results, cryogenic test set-up, irradiation tests, and cryogenic test results.

  8. Radiation requirements and testing of cryogenic thermometers for the ILC

    International Nuclear Information System (INIS)

    Barnett, T.; Filippov, Yu.P.; Mokhov, N.V.; Nakao, N.; Klebaner, A.L.; Korenev, S.A.; Theilacker, J.C.; Trenikhina, J.; Vaziri, K.

    2007-01-01

    Large quantity of cryogenic temperature sensors will be used for operation of the International Linear Collider (ILC). Most of them will be subject to high radiation doses during the accelerator lifetime. Understanding of particle energy spectra, accumulated radiation dose in thermometers and its impact on performance are vital in establishing technical specification of cryogenic thermometry for the ILC. Realistic MARS15 computer simulations were performed to understand the ILC radiation environment. Simulation results were used to establish radiation dose requirements for commercially available cryogenic thermometers. Two types of thermometers, Cernox(reg s ign) and TVO, were calibrated prior to irradiation using different technique. The sensors were subjected then to up to 200 kGy electron beam irradiation with kinetic energy of 5 MeV, a representative of the situation at the ILC operation. A post-irradiation behavior of the sensors was studied. The paper describes the MARS15 model, simulation results, cryogenic test set-up, irradiation tests, and cryogenic test results

  9. PEP radiation shielding tests in SLAC A Beam

    International Nuclear Information System (INIS)

    Ash, W.; DeStaebler, H.; Harris, J.; Jenkins, T.; Murray, J.

    1977-09-01

    Radiation shielding tests designed to simulate possible conditions in and around the PEP experimental halls were conducted. The SLAC A Beam was targeted in the block tunnel at a point about midway between End Station A and Beam Dump East. At that site it was relatively easy to rearrange the concrete block structure to simulate the various shielding configurations under consideration for PEP. Extensive surveys of neutron and ionizing radiation were made. Complete results of the shielding tests are given

  10. Radiated Emissions Test Approach

    Science.gov (United States)

    2015-10-02

    1. Draft Department of Transportation (DOT) Test Plan to Develop : Interference Tolerance Masks for GNSS Receivers in the L1 : Radiofrequency Band (1559 1610 MHz) provides high level : overview of radiated emissions test setup : 2. Presenta...

  11. Radiation Testing of PICA at the Solar Power Tower

    Science.gov (United States)

    White, Susan

    2010-01-01

    Sandia National Laboratory's Solar Power Tower was used to irradiate specimens of Phenolic Impregnated Carbon Ablator (PICA), in order to evaluate whether this thermal protection system material responded differently to potential shock layer radiative heating than to convective heating. Tests were run at 50, 100 and 150 Watts per square centimeter levels of concentrated solar radiation. Experimental results are presented both from spectral measurements on 1- 10 mm thick specimens of PICA, as well as from in-depth temperature measurements on instrumented thicker test specimens. Both spectral measurements and measured in-depth temperature profiles showed that, although it is a porous, low-density material, PICA does not exhibit problematic transparency to the tested high levels of NIR radiation, for all pragmatic cm-to-inch scale thicknesses. PICA acted as a surface absorber to efficiently absorb the incident visible and near infrared incident radiation in the top 2 millimeter layer in the Solar Power Tower tests up to 150 Watts per square centimeter.

  12. Radiation from Cardiac Imaging Tests

    Science.gov (United States)

    ... his or her test will be performed with attention paid to keeping radiation exposure low. Two Questions ... based, whereby less radiation is used to take pictures of skinnier patients. Questions for CT Angiograms Do ...

  13. Experimental test of liquid droplet radiator performance

    Science.gov (United States)

    Mattick, A. T.; Simon, M. A.

    The liquid droplet radiator (LDR) is a heat rejection system for space power systems wherein an array of heated liquid droplets radiates energy directly to space. The use of submillimeter droplets provides large radiating area-to-mass ratio, resulting in radiator systems which are several times lighter than conventional solid surface radiators. An experiment is described in which the power radiated by an array of 2300 streams of silicone oil droplets is measured to test a previously developed theory of the LDR radiation process. This system would be capable of rejecting several kW of heat in space. Furthermore, it would be suitable as a modular unit of an LDR designed for 100-kW power levels. The experiment provided confirmation of the theoretical dependence of droplet array emissivity on optical depth. It also demonstrated the ability to create an array of more than 1000 droplet streams having a divergence less than 1 degree.

  14. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Engineering Test Report: Radiated Emissions and SARR, SARP, DCS Receivers, Link Frequencies EMI Sensitive Band Test Results, AMSU-A1, S/N 109

    Science.gov (United States)

    Valdez, A.

    2000-01-01

    This is the Engineering Test Report, Radiated Emissions and SARR, SARP, DCS Receivers, Link Frequencies EMI Sensitive Band Test Results, AMSU-A1, S/N 109, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A).

  15. Current clinical trials testing combinations of immunotherapy and radiation.

    Science.gov (United States)

    Crittenden, Marka; Kohrt, Holbrook; Levy, Ronald; Jones, Jennifer; Camphausen, Kevin; Dicker, Adam; Demaria, Sandra; Formenti, Silvia

    2015-01-01

    Preclinical evidence of successful combinations of ionizing radiation with immunotherapy has inspired testing the translation of these results to the clinic. Interestingly, the preclinical work has consistently predicted the responses encountered in clinical trials. The first example came from a proof-of-principle trial started in 2001 that tested the concept that growth factors acting on antigen-presenting cells improve presentation of tumor antigens released by radiation and induce an abscopal effect. Granulocyte-macrophage colony-stimulating factor was administered during radiotherapy to a metastatic site in patients with metastatic solid tumors to translate evidence obtained in a murine model of syngeneic mammary carcinoma treated with cytokine FLT-3L and radiation. Subsequent clinical availability of vaccines and immune checkpoint inhibitors has triggered a wave of enthusiasm for testing them in combination with radiotherapy. Examples of ongoing clinical trials are described in this report. Importantly, most of these trials include careful immune monitoring of the patients enrolled and will generate important data about the proimmunogenic effects of radiation in combination with a variety of immune modulators, in different disease settings. Results of these studies are building a platform of evidence for radiotherapy as an adjuvant to immunotherapy and encourage the growth of this novel field of radiation oncology. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Radiation pressure actuation of test masses

    International Nuclear Information System (INIS)

    Garoi, F; Ju, L; Zhao, C; Blair, D G

    2004-01-01

    In this paper, we investigate the use of radiation pressure force as test mass actuation for laser interferometer gravitational wave detectors. It is shown that it is viable to provide radiation pressure control on test masses for frequencies above ∼0.2 Hz in high performance vibration isolation systems. A very low mass, low frequency resonator has been used to verify that radiation pressure force is not corrupted by other forces such as due to radiometer effects

  17. Orbiter radiator panel solar focusing test

    Science.gov (United States)

    Howell, H. R.; Rankin, J. G.

    1983-01-01

    Test data are presented which define the area around the Orbiter radiator panels for which the solar reflections are concentrated to one-sun or more. The concave shape of the panels and their specular silver/Teflon coating causes focusing of the reflected solar energy which could have adverse heating effects on equipment or astronaut extravehicular activity (EVA) in the vicinity of the radiator panels. A room ambient test method was utilized with a one-tenth scale model of the radiator panels.

  18. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Engineering Test Report: Radiated Emissions and SARR, SARP, DCS Receivers, Link Frequencies EMI Sensitive Band Test Results, AMSU-A1, S/N 108 2

    Science.gov (United States)

    Valdez, A.

    2000-01-01

    This is the Engineering Test Report, Radiated Emissions and SARR, SARP, DCS Receivers, Link Frequencies EMI Sensitive Band Test Results, AMSU-A1 SIN 108, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A).

  19. Radiation legacy of nuclear tests at the Semipalatinsk test site in the light of requirements ensuring radiation safety performance

    International Nuclear Information System (INIS)

    Logachev, V.A.; Logacheva, L.A.

    2005-01-01

    Peculiarities of nuclear tests radiation legacy at the Semipalatinsk test site (STS) are shown in the light of performance of requirements ensuring radiation safety, decrease radiation contamination levels in environment and minimize exposure of radiation for population residing contaminated areas by radioactive fallout. The paper provides data on characterization of peculiarities of the STS operation legacy based on review of archival data of the former 3-d General Administration under USSR Ministry of Health. (author)

  20. SLD liquid argon calorimeter prototype test results

    International Nuclear Information System (INIS)

    Dubois, R.; Eigen, G.; Au, Y.

    1985-10-01

    The results of the SLD test beam program for the selection of a calorimeter radiator composition within a liquid argon system are described, with emphasis on the study of the use of uranium to obtain equalization of pion and electron responses

  1. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Engineering Test Report: Radiated Emissions and SARR, SARP, DCS Receivers, Link Frequencies EMI Sensitive Band Test Results, AMSU-A2, S/N 108, 08

    Science.gov (United States)

    Valdez, A.

    2000-01-01

    This is the Engineering Test Report, Radiated Emissions and SARR, SARP, DCS Receivers, Link Frequencies EMI Sensitive Band Test Results, AMSU-A2, S/N 108, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A).

  2. Successful beam tests for ALICE Transition Radiation Detector

    CERN Multimedia

    2002-01-01

    Another round of beam tests of prototypes for the Transition Radiation Detector (TRD) for ALICE has been completed and there are already some good results. Mass production of the components of the detector will start early next year.   Top view of the setup for the Transition Radiation Detector prototype tests at CERN.On the left, can be seen the full-scale TRD prototype together with four smaller versions. These are busy days for the TRD (Transition Radiation Detector) team of ALICE. Twenty people - mainly from Germany, but also from Russia and Japan - were working hard during the beam tests this autumn at CERN to assess the performance of their detector prototypes. Analysis of the data shows that the TRD can achieve the desired physics goal even for the highest conceivable multiplicities in lead-lead collisions at the LHC. In its final configuration in the ALICE experiment, the TRD will greatly help in identifying high-momentum electrons, which are 'needles in a haystack' that consists mostly of...

  3. General gamma-radiation test of TGC detectors

    CERN Document Server

    Smakhtin, V P

    2004-01-01

    The TGC detectors are expected to provide the Muon trigger for the ATLAS detector in the forward region of the ATLAS Muon Spectrometer. The TGC detectors have to provide a trigger signal within 25 ns of the LHC accelerator bunch spacing, with an efficiency exceeding 95%, while exposed to an effective)photon and neutron background ranging from 30 to 150 Hz/cm/sup 2/. In order to test TGC detectors in high rate environment every detector was irradiated at 2500 Cu Co-60 source in Radiation Facility of Weizmann Institute of Science at nominal operating voltage and at photon rate several times above the expected background. This radiation test was succeeded in diagnostics of the hot spots inside detectors. The present publication refers to the test results of 800 TGC detectors produced in the Weizmann Institute of Science. (1 refs).

  4. ALICE TRD results from prototype tests

    CERN Document Server

    Andronic, A; Blume, C; Braun-Munzinger, P; Bucher, D; Catanescu, G; Ciobanu, M; Daues, H W; Devismes, A; Finck, C; Herrmann, N; Lister, T A; Mahmoud, Tariq; Peitzmann, Thomas; Petrovici, M; Reygers, K; Santo, R; Schicker, R; Sedykha, S; Simon, R S; Stachel, J; Stelzer, H; Wessels, J P; Winkelmann, O; Windelband, B; Xu, C

    2002-01-01

    We present results from tests of a prototype of the TRD for the ALICE experiment at LHC. We investigate the performance-of different radiator types, composed of foils, fibres and foams. The pion rejection performance for different methods of analysis over a momentum range from 0.7 to 2 GeV/c is presented. (8 refs).

  5. Radiation protection type testing and licensing of diagnostic X-ray equipment in the GDR

    International Nuclear Information System (INIS)

    Taschner, P.; Poulheim, K.F.; Feldheim, W.

    1987-01-01

    The results of more than 10 years experience in type testing and type licensing of diagnostic X-ray equipment with respect to meeting radiation protection requirements as well as the implications for the conduct of these procedures resulting from the introduction of new radiation protection legislation in 1983 and 1984, are described. At present an updated version of the 'Regulation of 16 December 1977 concerning radiation protection type testing and licensing of sealed radiation sources and equipment emitting ionizing radiation' is being prepared. (author)

  6. Boeing's STAR-FODB test results

    Science.gov (United States)

    Fritz, Martin E.; de la Chapelle, Michael; Van Ausdal, Arthur W.

    1995-05-01

    Boeing has successfully concluded a 2 1/2 year, two phase developmental contract for the STAR-Fiber Optic Data Bus (FODB) that is intended for future space-based applications. The first phase included system analysis, trade studies, behavior modeling, and architecture and protocal selection. During this phase we selected AS4074 Linear Token Passing Bus (LTPB) protocol operating at 200 Mbps, along with the passive, star-coupled fiber media. The second phase involved design, build, integration, and performance and environmental test of brassboard hardware. The resulting brassboard hardware successfully passed performance testing, providing 200 Mbps operation with a 32 X 32 star-coupled medium. This hardware is suitable for a spaceflight experiment to validate ground testing and analysis and to demonstrate performace in the intended environment. The fiber bus interface unit (FBIU) is a multichip module containing transceiver, protocol, and data formatting chips, buffer memory, and a station management controller. The FBIU has been designed for low power, high reliability, and radiation tolerance. Nine FBIUs were built and integrated with the fiber optic physical layer consisting of the fiber cable plant (FCP) and star coupler assembly (SCA). Performance and environmental testing, including radiation exposure, was performed on selected FBIUs and the physical layer. The integrated system was demonstrated with a full motion color video image transfer across the bus while simultaneously performing utility functions with a fiber bus control module (FBCM) over a telemetry and control (T&C) bus, in this case AS1773.

  7. GfW-handbook for irradiation test guidelines for radiation hardness of electronic components

    International Nuclear Information System (INIS)

    Braeunig, D.; Wulf, F.; Gaebler, W.; Boden, A.

    1982-12-01

    The purpose of the report is to propose irradiation test methods so that a standardized application of the methods can lead to a better comparison of test results. The interaction of different radiation species with matter - ionization and displacement - is described. Application of appropriate radiation sources, dosimetry problems, and shielding for simulating space radiation effects by laboratory testing is discussed. The description and characteristics of the irradiation sources are presented. Flowcharts of the planning and running of irradiation tests are given. Guidelines for running the tests are established, test methods and test circuits are proposed. The test system offers the capability of measuring devices also of high complexity up to microprocessors. The test results are collected regularly and are published in GfW-Handbook TN53/08, 'Data Compilation of Irradiation Tested Electronic Components'. (orig./HP) [de

  8. Nevada Test Site Radiation Protection Program - Revision 1

    International Nuclear Information System (INIS)

    Nevada Test Site Radiological Control Managers' Council

    2008-01-01

    Title 10 Code of Federal Regulations (CFR) Part 835, 'Occupational Radiation Protection,' establishes radiation protection standards, limits, and program requirements for protecting individuals from ionizing radiation resulting from the conduct of U.S. Department of Energy (DOE) activities. 10 CFR 835.101(a) mandates that DOE activities be conducted in compliance with a documented Radiation Protection Program (RPP) as approved by DOE. This document promulgates the RPP for the Nevada Test Site (NTS), related (on-site or off-site) U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO) operations, and environmental restoration off-site projects. This NTS RPP promulgates the radiation protection standards, limits, and program requirements for occupational exposure to ionizing radiation resulting from NNSA/NSO activities at the NTS and other operational areas as stated in 10 CFR 835.1(a). NNSA/NSO activities (including design, construction, operation, and decommissioning) within the scope of this RPP may result in occupational exposures to radiation or radioactive material. Therefore, a system of control is implemented through specific references to the site-specific NV/YMP RCM. This system of control is intended to ensure that the following criteria are met: (1) occupational exposures are maintained as low as reasonably achievable (ALARA), (2) DOE's limiting values are not exceeded, (3) employees are aware of and are prepared to cope with emergency conditions, and (4) employees are not inadvertently exposed to radiation or radioactive material

  9. Nevada Test Site Radiation Protection Program - Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Radiological Control Managers' Council

    2008-06-01

    Title 10 Code of Federal Regulations (CFR) Part 835, 'Occupational Radiation Protection,' establishes radiation protection standards, limits, and program requirements for protecting individuals from ionizing radiation resulting from the conduct of U.S. Department of Energy (DOE) activities. 10 CFR 835.101(a) mandates that DOE activities be conducted in compliance with a documented Radiation Protection Program (RPP) as approved by DOE. This document promulgates the RPP for the Nevada Test Site (NTS), related (on-site or off-site) U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO) operations, and environmental restoration off-site projects. This NTS RPP promulgates the radiation protection standards, limits, and program requirements for occupational exposure to ionizing radiation resulting from NNSA/NSO activities at the NTS and other operational areas as stated in 10 CFR 835.1(a). NNSA/NSO activities (including design, construction, operation, and decommissioning) within the scope of this RPP may result in occupational exposures to radiation or radioactive material. Therefore, a system of control is implemented through specific references to the site-specific NV/YMP RCM. This system of control is intended to ensure that the following criteria are met: (1) occupational exposures are maintained as low as reasonably achievable (ALARA), (2) DOE's limiting values are not exceeded, (3) employees are aware of and are prepared to cope with emergency conditions, and (4) employees are not inadvertently exposed to radiation or radioactive material.

  10. Design of online testing system of material radiation resistance

    International Nuclear Information System (INIS)

    Wan Junsheng; He Shengping; Gao Xinjun

    2014-01-01

    The capability of radiation resistance is important for some material used in some specifically engineering fields. It is the same principal applied in all existing test system that compares the performance parameter after radiation to evaluate material radiation resistance. A kind of new technique on test system of material radiation resistance is put forward in this paper. Experimentation shows that the online test system for material radiation resistance works well and has an extending application outlook. (authors)

  11. An equivalent ground thermal test method for single-phase fluid loop space radiator

    Directory of Open Access Journals (Sweden)

    Xianwen Ning

    2015-02-01

    Full Text Available Thermal vacuum test is widely used for the ground validation of spacecraft thermal control system. However, the conduction and convection can be simulated in normal ground pressure environment completely. By the employment of pumped fluid loops’ thermal control technology on spacecraft, conduction and convection become the main heat transfer behavior between radiator and inside cabin. As long as the heat transfer behavior between radiator and outer space can be equivalently simulated in normal pressure, the thermal vacuum test can be substituted by the normal ground pressure thermal test. In this paper, an equivalent normal pressure thermal test method for the spacecraft single-phase fluid loop radiator is proposed. The heat radiation between radiator and outer space has been equivalently simulated by combination of a group of refrigerators and thermal electrical cooler (TEC array. By adjusting the heat rejection of each device, the relationship between heat flux and surface temperature of the radiator can be maintained. To verify this method, a validating system has been built up and the experiments have been carried out. The results indicate that the proposed equivalent ground thermal test method can simulate the heat rejection performance of radiator correctly and the temperature error between in-orbit theory value and experiment result of the radiator is less than 0.5 °C, except for the equipment startup period. This provides a potential method for the thermal test of space systems especially for extra-large spacecraft which employs single-phase fluid loop radiator as thermal control approach.

  12. Beam test results of CMS RPCs at high eta region under high-radiation environment

    International Nuclear Information System (INIS)

    Park, S.; Ahn, S.H.; Bahk, S.Y.; Hong, B.; Hong, S.J.; Kang, D.H.; Kang, T.I.; Kim, T.J.; Kim, Y.J.; Kim, Y.U.; Koo, D.G.; Lee, H.W.; Lee, K.S.; Lee, S.J.; Lim, J.K.; Moon, D.H.; Nam, S.K.; Oh, J.K.; Park, W.J.; Rhee, J.T.; Ryu, M.S.; Shim, H.H.; Sim, K.S.

    2004-01-01

    The Compact Muon Solenoid (CMS) forward resistivity plate chambers (RPCs) at the high eta region must be operated in presence of a radiation-induced rate as high as 1kHz/cm2. It is still unknown if the RPCs coated with linseed oil can be operated under such a high-radiation environment over the lifetime of CMS. Non-oiled RPCs may be one of the options since phenolic or melamine-coated bakelite is chemically stabler than linseed oil. We have constructed oiled and non-oiled RPCs at the high eta region of CMS using phenolic bakelite and tested them in the Gamma Irradiation Facility at CERN. While both RPCs show the same characteristics in the efficiency and the strip multiplicity, the non-oiled RPC generates an intrinsic noise rate of 50Hz/cm2, compared to only 5Hz/cm2 for the oiled RPC, both at 10.0kV which is about 100V above the 95% knee of the efficiency curve

  13. Beam test results of CMS RPCs at high eta region under high-radiation environment

    CERN Document Server

    Park, S; Bahk, S Y; Hong, B; Hong, S J; Kang, D H; Kang, T I; Kim, T J; Kim, Y J; Kim, Y U; Koo, D G; Lee, H W; Lee, K S; Lee, S J; Lim, J K; Moon, D H; Nam, S K; Oh, J K; Park, W J; Rhee, J T; Ryu, M S; Shim, H H; Sim, K S

    2004-01-01

    The Compact Muon Solenoid (CMS) forward resistivity plate chambers (RPCs) at the high eta region must be operated in presence of a radiation-induced rate as high as 1 kHz/cm**2. It is still unknown if the RPCs coated with linseed oil can be operated under such a high- radiation environment over the lifetime of CMS. Non-oiled RPCs may be one of the options since phenolic or melamine-coated bakelite is chemically stabler than linseed oil. We have constructed oiled and non-oiled RPCs at the high eta region of CMS using phenolic bakelite and tested them in the Gamma Irradiation Facility at CERN. While both RPCs show the same characteristics in the efficiency and the strip multiplicity, the non-oiled RPC generates an intrinsic noise rate of 50 Hz/cm**2, compared to only 5 Hz/cm**2 for the oiled RPC, both at 10.0kV which is about 100 V above the 95% knee of the efficiency curve.

  14. Deep space test bed for radiation studies

    International Nuclear Information System (INIS)

    Adams, James H.; Adcock, Leonard; Apple, Jeffery; Christl, Mark; Cleveand, William; Cox, Mark; Dietz, Kurt; Ferguson, Cynthia; Fountain, Walt; Ghita, Bogdan; Kuznetsov, Evgeny; Milton, Martha; Myers, Jeremy; O'Brien, Sue; Seaquist, Jim; Smith, Edward A.; Smith, Guy; Warden, Lance; Watts, John

    2007-01-01

    The Deep Space Test-Bed (DSTB) Facility is designed to investigate the effects of galactic cosmic rays on crews and systems during missions to the Moon or Mars. To gain access to the interplanetary ionizing radiation environment the DSTB uses high-altitude polar balloon flights. The DSTB provides a platform for measurements to validate the radiation transport codes that are used by NASA to calculate the radiation environment within crewed space systems. It is also designed to support other exploration related investigations such as measuring the shielding effectiveness of candidate spacecraft and habitat materials, testing new radiation monitoring instrumentation, flight avionics and investigating the biological effects of deep space radiation. We describe the work completed thus far in the development of the DSTB and its current status

  15. ANOLE Portable Radiation Detection System Field Test and Evaluation Campaign

    International Nuclear Information System (INIS)

    Hodge, Chris A.

    2007-01-01

    Handheld, backpack, and mobile sensors are elements of the Global Nuclear Detection System for the interdiction and control of illicit radiological and nuclear materials. They are used by the U.S. Department of Homeland Security (DHS) and other government agencies and organizations in various roles for border protection, law enforcement, and nonproliferation monitoring. In order to systematically document the operational performance of the common commercial off-the-shelf portable radiation detection systems, the DHS Domestic Nuclear Detection Office conducted a test and evaluation campaign conducted at the Nevada Test Site from January 18 to February 27, 2006. Named 'Anole', it was the first test of its kind in terms of technical design and test complexities. The Anole test results offer users information for selecting appropriate mission-specific portable radiation detection systems. The campaign also offered manufacturers the opportunity to submit their equipment for independent operationally relevant testing to subsequently improve their detector performance. This paper will present the design, execution, and methodologies of the DHS Anole portable radiation detection system test campaign

  16. Radiation Isotope Identification Device (RIIDs) Field Test and Evaluation Campaign

    International Nuclear Information System (INIS)

    Christopher Hodge, Raymond Keegan

    2007-01-01

    Handheld, backpack, and mobile sensors are elements of the Global Nuclear Detection System for the interdiction and control of illicit radiological and nuclear materials. They are used by the U.S. Department of Homeland Security (DHS) and other government agencies and organizations in various roles for border protection, law enforcement, and nonproliferation monitoring. In order to systematically document the operational performance of the common commercial off-the-shelf portable radiation detection systems, the DHS Domestic Nuclear Detection Office conducted a test and evaluation campaign conducted at the Nevada Test Site from January 18 to February 27, 2006. Named 'Anole', it was the first test of its kind in terms of technical design and test complexities. The Anole test results offer users information for selecting appropriate mission-specific portable radiation detection systems. The campaign also offered manufacturers the opportunity to submit their equipment for independent operationally relevant testing to subsequently improve their detector performance. This paper will present the design, execution, and methodologies of the DHS Anole portable radiation detection system test campaign

  17. Radiation testing of electronics for the CMS endcap muon system

    Energy Technology Data Exchange (ETDEWEB)

    Bylsma, B. [Ohio State University (United States); Cady, D.; Celik, A. [Texas A and M University, College Station, TX 77843 (United States); Durkin, L.S. [Ohio State University (United States); Gilmore, J., E-mail: gilmore@tamu.edu [Texas A and M University, College Station, TX 77843 (United States); Haley, J. [Northeastern University (United States); Khotilovich, V.; Lakdawala, S. [Texas A and M University, College Station, TX 77843 (United States); Liu, J.; Matveev, M.; Padley, B.P.; Roberts, J. [Rice University (United States); Roe, J.; Safonov, A.; Suarez, I. [Texas A and M University, College Station, TX 77843 (United States); Wood, D. [Northeastern University (United States); Zawisza, I. [Texas A and M University, College Station, TX 77843 (United States)

    2013-01-11

    The electronics used in the data readout and triggering system for the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) particle accelerator at CERN are exposed to high radiation levels. This radiation can cause permanent damage to the electronic circuitry, as well as temporary effects such as data corruption induced by Single Event Upsets. Once the High Luminosity LHC (HL-LHC) accelerator upgrades are completed it will have five times higher instantaneous luminosity than LHC, allowing for detection of rare physics processes, new particles and interactions. Tests have been performed to determine the effects of radiation on the electronic components to be used for the Endcap Muon electronics project currently being designed for installation in the CMS experiment in 2013. During these tests the digital components on the test boards were operating with active data readout while being irradiated with 55 MeV protons. In reactor tests, components were exposed to 30 years equivalent levels of neutron radiation expected at the HL-LHC. The highest total ionizing dose (TID) for the muon system is expected at the innermost portion of the CMS detector, with 8900 rad over 10 years. Our results show that Commercial Off-The-Shelf (COTS) components selected for the new electronics will operate reliably in the CMS radiation environment.

  18. Radiation testing of electronics for the CMS endcap muon system

    Science.gov (United States)

    Bylsma, B.; Cady, D.; Celik, A.; Durkin, L. S.; Gilmore, J.; Haley, J.; Khotilovich, V.; Lakdawala, S.; Liu, J.; Matveev, M.; Padley, B. P.; Roberts, J.; Roe, J.; Safonov, A.; Suarez, I.; Wood, D.; Zawisza, I.

    2013-01-01

    The electronics used in the data readout and triggering system for the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) particle accelerator at CERN are exposed to high radiation levels. This radiation can cause permanent damage to the electronic circuitry, as well as temporary effects such as data corruption induced by Single Event Upsets. Once the High Luminosity LHC (HL-LHC) accelerator upgrades are completed it will have five times higher instantaneous luminosity than LHC, allowing for detection of rare physics processes, new particles and interactions. Tests have been performed to determine the effects of radiation on the electronic components to be used for the Endcap Muon electronics project currently being designed for installation in the CMS experiment in 2013. During these tests the digital components on the test boards were operating with active data readout while being irradiated with 55 MeV protons. In reactor tests, components were exposed to 30 years equivalent levels of neutron radiation expected at the HL-LHC. The highest total ionizing dose (TID) for the muon system is expected at the innermost portion of the CMS detector, with 8900 rad over 10 years. Our results show that Commercial Off-The-Shelf (COTS) components selected for the new electronics will operate reliably in the CMS radiation environment.

  19. Modern instrumentation for radiation introscopic testing of welding quality

    International Nuclear Information System (INIS)

    Sosnin, F.R.

    1985-01-01

    Modern instrumenlation used for radiation introscopy of welded joints is discussed. the absolute (relative) sensitivity of radiation testing, resolution range, efficiency are considered as basic parameters of introscopes. The characteristics of fluoroscopes, radiation-television installations with the external scintillator and radiative image converter as well as with X-ray vidicons are given. The characterisitcs of radiation introscopes with manipulators to move objects being tested are analysed as well as digitized radiation introscopes

  20. The feasibility of 10 keV X-ray as radiation source in total dose response radiation test

    International Nuclear Information System (INIS)

    Li Ruoyu; Li Bin; Luo Hongwei; Shi Qian

    2005-01-01

    The standard radiation source utilized in traditional total dose response radiation test is 60 Co, which is environment-threatening. X-rays, as a new radiation source, has the advantages such as safety, precise control of dose rate, strong intensity, possibility of wafer-level test or even on-line test, which greatly reduce cost for package, test and transportation. This paper discussed the feasibility of X-rays replacing 60 Co as the radiation source, based on the radiation mechanism and the effects of radiation on gate oxide. (authors)

  1. Radiation-related monitoring and environmental research at the Nevada Test Site

    International Nuclear Information System (INIS)

    Anspaugh, L.R.; Patton, S.E.; Shinn, J.H.; Black, S.C.; Costa, C.F.; Elle, D.R.; Essington, E.H.; Gilbert, R.O.; Gonzalez, D.A.; Hunter, R.B.; Medica, P.A.; McArthur, R.D.; Thompson, C.B.; O'Farrell, T.P.; Romney, E.M.

    1990-01-01

    Beginning with the first nuclear-weapons-related tests at the Nevada Test Site (NTS) in 1951, a radiation-related monitoring program was established to determine the levels and distribution of radionuclides released. Primary methods involved survey-meter-equipped field-monitoring teams and placement of film badges and air-sampling devices at fixed locations. Beginning in the mid-1950s, more stringent standards, the results of this monitoring program, and the results of related research programs led to increased engineering efforts to reduce local fallout. With passage of the National Environmental Policy Act and increased concern about possible effects of radiation exposure, environmental activities related to the NTS increased. There is now an extensive monitoring program at the NTS to assess radiological conditions resulting from past tests and from continued testing of nuclear-weapons devices. In populated areas near NTS, there is also a monitoring effort that relies on assistance from local communities. Other efforts include reconstruction of radiation doses received by offsite residents during the 1950s and 1960s, determination of the current inventory and distribution of radionuclides in surface soil, and studies of the movement of radionuclides in the desert ecosystem

  2. Reliability of an x-ray system for calibrating and testing personal radiation dosimeters

    Science.gov (United States)

    Guimarães, M. C.; Silva, C. R. E.; Rosado, P. H. G.; Cunha, P. G.; Da Silva, T. A.

    2018-03-01

    Metrology laboratories are expected to maintain standardized radiation beams and traceable standard dosimeters to provide reliable calibrations or testing of detectors. Results of the characterization of an x-ray system for performing calibration and testing of radiation dosimeters used for individual monitoring are shown in this work.

  3. Reliability of an x-ray system for calibrating and testing personal radiation dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Guimarães, M.C.; Silva, C.R.E.; Silva, T.A. da [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Rosado, P.H.G.; Cunha, P.G. [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    Metrology laboratories are expected to maintain standardized radiation beams and traceable standard dosimeters to provide reliable calibrations or testing of detectors. Results of the characterization of an x-ray system for performing calibration and testing of radiation dosimeters used for individual monitoring are shown in this work. (author)

  4. Reliability of an x-ray system for calibrating and testing personal radiation dosimeters

    International Nuclear Information System (INIS)

    Guimarães, M.C.; Silva, C.R.E.; Silva, T.A. da; Rosado, P.H.G.; Cunha, P.G.

    2017-01-01

    Metrology laboratories are expected to maintain standardized radiation beams and traceable standard dosimeters to provide reliable calibrations or testing of detectors. Results of the characterization of an x-ray system for performing calibration and testing of radiation dosimeters used for individual monitoring are shown in this work. (author)

  5. Evaluation of methods to leak test sealed radiation sources

    International Nuclear Information System (INIS)

    Arbeau, N.D.; Scott, C.K.

    1987-04-01

    The methods for the leak testing of sealed radiation sources were reviewed. One hundred and thirty-one equipment vendors were surveyed to identify commercially available leak test instruments. The equipment is summarized in tabular form by radiation type and detector type for easy reference. The radiation characteristics of the licensed sources were reviewed and summarized in a format that can be used to select the most suitable detection method. A test kit is proposed for use by inspectors when verifying a licensee's test procedures. The general elements of leak test procedures are discussed

  6. BARTTest: Community-Standard Atmospheric Radiative-Transfer and Retrieval Tests

    Science.gov (United States)

    Harrington, Joseph; Himes, Michael D.; Cubillos, Patricio E.; Blecic, Jasmina; Challener, Ryan C.

    2018-01-01

    Atmospheric radiative transfer (RT) codes are used both to predict planetary and brown-dwarf spectra and in retrieval algorithms to infer atmospheric chemistry, clouds, and thermal structure from observations. Observational plans, theoretical models, and scientific results depend on the correctness of these calculations. Yet, the calculations are complex and the codes implementing them are often written without modern software-verification techniques. The community needs a suite of test calculations with analytically, numerically, or at least community-verified results. We therefore present the Bayesian Atmospheric Radiative Transfer Test Suite, or BARTTest. BARTTest has four categories of tests: analytically verified RT tests of simple atmospheres (single line in single layer, line blends, saturation, isothermal, multiple line-list combination, etc.), community-verified RT tests of complex atmospheres, synthetic retrieval tests on simulated data with known answers, and community-verified real-data retrieval tests.BARTTest is open-source software intended for community use and further development. It is available at https://github.com/ExOSPORTS/BARTTest. We propose this test suite as a standard for verifying atmospheric RT and retrieval codes, analogous to the Held-Suarez test for general circulation models. This work was supported by NASA Planetary Atmospheres grant NX12AI69G, NASA Astrophysics Data Analysis Program grant NNX13AF38G, and NASA Exoplanets Research Program grant NNX17AB62G.

  7. Radiation testing campaign results for understanding the suitability of FPGAs in detector electronics

    Energy Technology Data Exchange (ETDEWEB)

    Citterio, M., E-mail: mauro.citterio@mi.infn.it [INFN Milan, Milan (Italy); Camplani, A. [INFN Milan, Milan (Italy); Cannon, M. [Brigham Young University, Provo (United States); Chen, H.; Chen, K. [Brookhaven National Laboratory, Upton, NY (United States); Deng, B.; Liu, C. [Southern Methodist University, Dallas (United States); Meroni, C. [INFN Milan, Milan (Italy); Kierstead, J.; Takai, H. [Brookhaven National Laboratory, Upton, NY (United States); Wirthlin, M. [Brigham Young University, Provo (United States); Ye, J. [Southern Methodist University, Dallas (United States)

    2016-07-11

    SRAM based Field Programmable Gate Arrays (FPGAs) have been rarely used in High Energy Physics (HEP) due to their sensitivity to radiation. The last generation of commercial FPGAs based on 28 nm feature size and on Silicon On Insulator (SOI) technologies are more tolerant to radiation to the level that their use in front-end electronics is now feasible. FPGAs provide re-programmability, high-speed computation and fast data transmission through the embedded serial transceivers. They could replace custom application specific integrated circuits in front end electronics in locations with moderate radiation field. The use of a FPGA in HEP experiments is only limited by our ability to mitigate single event effects induced by the high energy hadrons present in the radiation field. - Highlights: • Radiation campaign on Xilinx Kintex 7 FPGAs. • Use of FPGAs in high energy physics. • Evaluation of configuration RAM and block RAM parameters after irradiation.

  8. Solar panel thermal cycling testing by solar simulation and infrared radiation methods

    Science.gov (United States)

    Nuss, H. E.

    1980-01-01

    For the solar panels of the European Space Agency (ESA) satellites OTS/MAROTS and ECS/MARECS the thermal cycling tests were performed by using solar simulation methods. The performance data of two different solar simulators used and the thermal test results are described. The solar simulation thermal cycling tests for the ECS/MARECS solar panels were carried out with the aid of a rotatable multipanel test rig by which simultaneous testing of three solar panels was possible. As an alternative thermal test method, the capability of an infrared radiation method was studied and infrared simulation tests for the ultralight panel and the INTELSAT 5 solar panels were performed. The setup and the characteristics of the infrared radiation unit using a quartz lamp array of approx. 15 sq and LN2-cooled shutter and the thermal test results are presented. The irradiation uniformity, the solar panel temperature distribution, temperature changing rates for both test methods are compared. Results indicate the infrared simulation is an effective solar panel thermal testing method.

  9. Compilation of radiation damage test data

    International Nuclear Information System (INIS)

    Schoenbacher, H.; Tavlet, M.

    1989-01-01

    This report summarizes radiation damage test data on commercially available organic cable insulation and jacket materials: Ethylene-propylene rubbers, polyethylenes, polyurethanes, silicone rubbers, and copolymers based on polyethylene. The materials have been irradiated either in a nuclear reactor, or with a cobalt-60 source, or in the CERN accelerators, at different dose rates. The absorbed doses were between 10 3 and 5x10 6 Gy. Mechanical properties, e.g. tensile strength, elongation at break, and hardness, have been tested on irradiated and non-irradiated samples, according to the recommendations of the International Electrotechnical Commission. The results are presented in the form of tables and graphs to show the effect of the absorbed dose on the measured properties. (orig.)

  10. Analytical method and result of radiation exposure for depressurization accident of HTTR

    International Nuclear Information System (INIS)

    Sawa, K.; Shiozawa, S.; Mikami, H.

    1990-01-01

    The Japan Atomic Energy Research Institute (JAERI) is now proceeding with the construction design of the High Temperature Engineering Test Reactor (HTTR). Since the HTTR has some characteristics different from LWRs, analytical method of radiation exposure in accidents provided for LWRs can not be applied directly. This paper describes the analytical method of radiation exposure developed by JAERI for the depressurization accident, which is the severest accident in respect to radiation exposure among the design basis accidents of the HTTR. The result is also described in this paper

  11. Compilation of radiation damage test data. I

    International Nuclear Information System (INIS)

    Schoenbacher, H.; Stolarz-Izycka, A.

    1979-01-01

    This report summarizes radiation damage test data on commercially available organic cable insulation and jacket materials: ethylene-propylene rubber, Hypalon, neoprene rubber, polyethylene, polyurethane, polyvinylchloride, silicone rubber, etc. The materials have been irradiated in a nuclear reactor to integrated absorbed doses from 5 X 10 5 to 5 X 10 6 Gy. Mechanical properties, e.g. tensile strength, elongation at break, and hardness, have been tested on irradiated and non-irradiated samples. The results are presented in the form of tables and graphs, to show the effect of the absorbed dose on the measured properties. (Auth.)

  12. Radiation Tests of Single Photon Avalanche Diode for Space Applications

    Science.gov (United States)

    Moscatelli, Francesco; Marisaldi, Martino; MacCagnani, Piera; Labanti, Claudio; Fuschino, Fabio; Prest, Michela; Berra, Alessandro; Bolognini, Davide; Ghioni, Massimo; Rech, Ivan; hide

    2013-01-01

    Single photon avalanche diodes (SPADs) have been recently studied as photodetectors for applications in space missions. In this presentation we report the results of radiation hardness test on large area SPAD (actual results refer to SPADs having 500 micron diameter). Dark counts rate as low as few kHz at -10 degC has been obtained for the 500 micron devices, before irradiation. We performed bulk damage and total dose radiation tests with protons and gamma-rays in order to evaluate their radiation hardness properties and their suitability for application in a Low Earth Orbit (LEO) space mission. With this aim SPAD devices have been irradiated using up to 20 krad total dose with gamma-rays and 5 krad with protons. The test performed show that large area SPADs are very sensitive to proton doses as low as 2×10(exp 8) (1 MeV eq) n/cm2 with a significant increase in dark counts rate (DCR) as well as in the manifestation of the "random telegraph signal" effect. Annealing studies at room temperature (RT) and at 80 degC have been carried out, showing a high decrease of DCR after 24-48 h at RT. Lower protons doses in the range 1-10×10(exp 7) (1 MeV eq) n/cm(exp 2) result in a lower increase of DCR suggesting that the large-area SPADs tested in this study are well suitable for application in low-inclination LEO, particularly useful for gamma-ray astrophysics.

  13. Irradiation tests of critical components for remote handling in gamma radiation environment

    International Nuclear Information System (INIS)

    Obara, Henjiro; Kakudate, Satoshi; Oka, Kiyoshi

    1994-08-01

    Since the fusion power core of a D-T fusion reactor will be highly activated once it starts operation, personnel access will be prohibited so that assembly and maintenance of the components in the reactor core will have to be totally conducted by remote handling technology. Fusion experimental reactors such as ITER require unprecedented remote handling equipments which are tolerable under gamma radiation of more than 10 6 R/h. For this purpose, the Japan Atomic Energy Research Institute (JAERI) has been developing radiation hard components for remote handling purpose and a number of key components have been tested over 10 9 rad at a radiation dose rate of around 10 6 R/h, using Gamma Ray Radiation Test Facility in JAERI-Takasaki Establishment. This report summarizes the irradiation test results and the latest status of AC servo motor, potentiometer, optical elements, lubricant, sensors and cables, which are key elements of the remote handling system. (author)

  14. Results from phase 2 of the radioiodine test facility experimental program

    Energy Technology Data Exchange (ETDEWEB)

    Ball, J M; Kupferschmid, W C.H.; Wren, J C [Atomic Energy of Canada Ltd., Pinawa, MB (Canada). Whiteshell Labs.

    1996-12-01

    A series of intermediate-scale experiments were conducted in the Radioiodine Test Facility (RTF) in a vinyl-painted, zinc-primer coated, carbon steel vessel in order to assess the effects of vinyl surfaces on iodine volatility in both the presence and absence of radiation. This test series, Phase 2 of a larger, comprehensive program assessing a variety of containment surfaces, also examined the effects of organic (i.e., methyl ethyl ketone) and inorganic (i.e., hydrazine) additives, pH, and venting on the aqueous chemistry and volatility of solutions initially containing cesium iodide. These tests have clearly demonstrated that organics are released to the aqueous phase from the vinyl coating and that, under radiation conditions, these organics can have a significant effect on the formation of volatile iodine species. In particular, the RTF results suggest that radiolytic decomposition of the released organics results in dramatic reductions in pH and dissolved oxygen concentration, which in turn are responsible for increased formation of molecular iodine and organic iodides. When the pH was maintained at 10 (Test 3), much lower iodine volatility was observed; low iodine volatility was also observed in the absence of radiation. This test series also demonstrated that vinyl surfaces, particularly those in contact with the gas phase, were a sink for iodine. (author) 4 figs., 6 tabs., 17 refs.

  15. Results from phase 2 of the radioiodine test facility experimental program

    International Nuclear Information System (INIS)

    Ball, J.M.; Kupferschmid, W.C.H.; Wren, J.C.

    1996-01-01

    A series of intermediate-scale experiments were conducted in the Radioiodine Test Facility (RTF) in a vinyl-painted, zinc-primer coated, carbon steel vessel in order to assess the effects of vinyl surfaces on iodine volatility in both the presence and absence of radiation. This test series, Phase 2 of a larger, comprehensive program assessing a variety of containment surfaces, also examined the effects of organic (i.e., methyl ethyl ketone) and inorganic (i.e., hydrazine) additives, pH, and venting on the aqueous chemistry and volatility of solutions initially containing cesium iodide. These tests have clearly demonstrated that organics are released to the aqueous phase from the vinyl coating and that, under radiation conditions, these organics can have a significant effect on the formation of volatile iodine species. In particular, the RTF results suggest that radiolytic decomposition of the released organics results in dramatic reductions in pH and dissolved oxygen concentration, which in turn are responsible for increased formation of molecular iodine and organic iodides. When the pH was maintained at 10 (Test 3), much lower iodine volatility was observed; low iodine volatility was also observed in the absence of radiation. This test series also demonstrated that vinyl surfaces, particularly those in contact with the gas phase, were a sink for iodine. (author) 4 figs., 6 tabs., 17 refs

  16. Radiation monitoring around United States nuclear test areas, calendar year 1989

    International Nuclear Information System (INIS)

    1990-05-01

    This report describes the Offsite Radiation Safety Program conducted during 1989 by the Environmental Protection Agency's (EPA's) Environmental Monitoring Systems Laboratory-Las Vegas (EMSL-LV). This laboratory operates an environmental radiation monitoring program in the region surrounding the Nevada Test Site (NTS) and at former test sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The surveillance program is designed to measure levels, and trends of radioactivity, if present, in the environment surrounding testing areas to ascertain whether the testing is in compliance with existing radiation protection standards, and to take action to protect the health and well being of the public in the event of any accidental release of radioactive contaminants. Offsite levels of radiation and radioactivity are assessed by sampling milk, water, and air; by deploying thermoluminescent dosimeters (TLDs) and using pressurized ion chambers (PICs); and by biological monitoring of both animals and humans. To implement protective actions, provide immediate radiation monitoring, and obtain environmental samples rapidly after any release of radioactivity, personnel with mobile monitoring equipment are placed in areas downwind from the test site prior to each test. Comparison of the measurements and sample analysis results with background levels and with appropriate standards and regulations indicated that there was no radioactivity detected offsite by the various EPA monitoring networks and no exposure above natural background to the population living in the vicinity of the NTS that could be attributed to NTS activities. Trends were evaluated in the Noble Gas and Tritium, Milk Surveillance, TLD, and PIC networks, and the Long-Term Hydrological Monitoring Program. 35 refs., 68 figs., 32 tabs

  17. Radiation monitoring around United States nuclear test areas, calendar year 1989

    Energy Technology Data Exchange (ETDEWEB)

    1990-05-01

    This report describes the Offsite Radiation Safety Program conducted during 1989 by the Environmental Protection Agency's (EPA's) Environmental Monitoring Systems Laboratory-Las Vegas (EMSL-LV). This laboratory operates an environmental radiation monitoring program in the region surrounding the Nevada Test Site (NTS) and at former test sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The surveillance program is designed to measure levels, and trends of radioactivity, if present, in the environment surrounding testing areas to ascertain whether the testing is in compliance with existing radiation protection standards, and to take action to protect the health and well being of the public in the event of any accidental release of radioactive contaminants. Offsite levels of radiation and radioactivity are assessed by sampling milk, water, and air; by deploying thermoluminescent dosimeters (TLDs) and using pressurized ion chambers (PICs); and by biological monitoring of both animals and humans. To implement protective actions, provide immediate radiation monitoring, and obtain environmental samples rapidly after any release of radioactivity, personnel with mobile monitoring equipment are placed in areas downwind from the test site prior to each test. Comparison of the measurements and sample analysis results with background levels and with appropriate standards and regulations indicated that there was no radioactivity detected offsite by the various EPA monitoring networks and no exposure above natural background to the population living in the vicinity of the NTS that could be attributed to NTS activities. Trends were evaluated in the Noble Gas and Tritium, Milk Surveillance, TLD, and PIC networks, and the Long-Term Hydrological Monitoring Program. 35 refs., 68 figs., 32 tabs.

  18. Algae as test organisms of harmful effects of various radiations

    International Nuclear Information System (INIS)

    Necas, J.

    1989-01-01

    The report describes a complex biotest in which algae serve as the test organisms and where a variety of algal characteristics are employed as indicators of the effects of harmful radiations on the cultures and single organisms. Rules for a successful choice of a suitable algal organism are discussed and the preparation of the latter for the test as well as the growth and morphogenic tests and some physiological responses of algae to harmful radiation are described. The survival and lethality are related to the interpretation of the test results particularly from the physiological and genetic points of view. The complex biotest concerns not only toxic but also mutagenic effects of the factors tested. Some easily detectable mutations in algae are mentioned and their spectra are recommended. The stability of the mutations and the possibility of their delayed manifestation are considered. The possibility of occurrence of teratogenic effects is also dealt with and the negative role of phenocopies in the correct evaluation of the mutation effects is mentioned. Advice for the breeding and laboratory maintenance of suitable algal strains for the biotest is given. Practical use of the biotest is demonstrated on the results of a test using modified samples of waste water from uranium industries. It is recommended that biotests confined to the evaluation of single characteristics of the test organism be replaced by this complex biotest whose results can be interpreted more extensively and exhibit a higher reliability. (author). 268 refs., 1 tab., 9 figs

  19. Neurobehavioral Effects of Space Radiation on Psychomotor Vigilance Tests

    Science.gov (United States)

    Hienz, Robert; Davis, Catherine; Weed, Michael; Guida, Peter; Gooden, Virginia; Brady, Joseph; Roma, Peter

    -red-light stimulus (LED-digital counter) as soon as the stimulus appears, which stops the stimulus counter and displays the reaction time for each trial in milliseconds for a 1-sec period. Simple to perform, the PVT has only very minor learning effects, is widely used in human risk assessments in operational environments, and has been recently developed and adopted for use on the ISS for astronauts as a "self test" to provide performance feedback, detect changes in alertness, prevent errors, and manage fatigue from sleep loss, circadian dis-ruption, and high workload requirements. A rodent version of the PVT, the rPVT, has been developed and demonstrated to track the same types of performance variables as the human PVT -i.e., general motor function and speed, fine motor control, inhibitory control ("impul-sivity"), timing, selective attention, motivation, and basic sensory function. Five cohorts of 16 rats each (total N = 80) were trained on the rPVT, exported to BNL for head-only radiation exposure (0, 25, 50, 100, and 200 cGy protons @ 150 MeV/n), then returned to Johns Hopkins for follow-up testing. RESULTS The rPVT was readily learned by all rats and required as little as 5-7 days of training to acquire baseline performance levels. Following irradiation, performances in the rPVT were disrupted at exposure levels of 50, 100, and 200 cGy, showing a consistent, significant increase (i.e., slowing) in reaction times and increased lapses in responding, both indicative of a decrease in sustained attention. Additionally, premature responses showed consistent increases at the higher radiation levels. None of these changes were observed in the non-exposed control animals. Over this same time period, no significant changes were observed in discrimination accuracy, motivation (as indicated by trials completed), or food intake. SUMMARY AND CONCLUSIONS The results of these experiments demonstrate the sensitivity of tests such as the rPVT for assessing the effects of head-only space radiation

  20. Field test of a post-closure radiation monitor

    International Nuclear Information System (INIS)

    Reed, S.; Christy, C.E.; Heath, R.E.

    1995-01-01

    The DOE is conducting remedial actions at many sites contaminated with radioactive materials. After closure of these sites, long-term subsurface monitoring is typically required by law. This monitoring is generally labor intensive and expensive using conventional sampling and analysis techniques. The U.S. Department of Energy's Morgantown Energy Technology Center (METC) has contracted with Babcock and Wilcox to develop a Long-Term Post-Closure Radiation Monitoring System (LPRMS) to reduce these monitoring costs. A prototype LPRMS probe was built, and B ampersand W and FERMCO field tested this monitoring probe at the Fernald Environmental Management Project in the fall of 1994 with funding from the DOE's Office of Technology Development (EM-50) through METC. The system was used to measure soil and water with known uranium contamination levels, both in drums and in situ at depths up to 3 meters. For comparison purposes, measurements were also performed using a more conventional survey probe with a sodium iodide scintillator directly butt-coupled to detection electronics. This paper presents a description and the results of the field tests. The results were used to characterize the lower detection limits, precision and bias of the system, which allowed the DOE to judge the monitoring system's ability to meet its long-term post-closure radiation monitoring needs. Based on the test results, the monitoring system has been redesigned for fabrication and testing in a potential Phase III of this program. If the DOE feels that this system can meet its needs and chooses to continue into Phase III of this program, this redesigned full scale prototype system will be built and tested for a period of approximately a year. Such a system can be used at a variety of radioactively contaminated sites

  1. Acute Radiation Effects Resulting from Exposure to Solar Particle Event-Like Radiation

    Science.gov (United States)

    Kennedy, Ann; Cengel, Keith

    2012-07-01

    A major solar particle event (SPE) may place astronauts at significant risk for the acute radiation syndrome (ARS), which may be exacerbated when combined with other space flight stressors, such that the mission or crew health may be compromised. The National Space Biomedical Research Institute (NSBRI) Center of Acute Radiation Research (CARR) is focused on the assessment of risks of adverse biological effects related to the ARS in animal models exposed to space flight stressors combined with the types of radiation expected during an SPE. As part of this program, FDA-approved drugs that may prevent and/or mitigate ARS symptoms are being evaluated. The CARR studies are focused on the adverse biological effects resulting from exposure to the types of radiation, at the appropriate energies, doses and dose-rates, present during an SPE (and standard reference radiations, gamma rays or electrons). The ARS is a phased syndrome which often includes vomiting and fatigue. Other acute adverse biologic effects of concern are the loss of hematopoietic cells, which can result in compromised bone marrow and immune cell functions. There is also concern for skin damage from high SPE radiation doses, including burns, and resulting immune system dysfunction. Using 3 separate animal model systems (ferrets, mice and pigs), the major ARS biologic endpoints being evaluated are: 1) vomiting/retching and fatigue, 2) hematologic changes (with focus on white blood cells) and immune system changes resulting from exposure to SPE radiation with and without reduced weightbearing conditions, and 3) skin injury and related immune system functions. In all of these areas of research, statistically significant adverse health effects have been observed in animals exposed to SPE-like radiation. Countermeasures for the management of ARS symptoms are being evaluated. New research findings from the past grant year will be discussed. Acknowledgements: This research is supported by the NSBRI Center of Acute

  2. ALICE Transition Radiation Detector (TRD), test beam.

    CERN Multimedia

    2003-01-01

    Electrons and positrons can be discriminated from other charged particles using the emission of transition radiation - X-rays emitted when the particles cross many layers of thin materials. To develop such a Transition Radiation Detector(TRD) for ALICE many detector prototypes were tested in mixed beams of pions and electrons, as in the example shown here.

  3. Nuclear technology in materials testing and radiation protection

    International Nuclear Information System (INIS)

    Neider, R.

    1975-01-01

    A report of the 1974 activities of the laboratories for physical and measuring technical fundamentals, radiation effects and radiation protection, application of radionuclides and testing of radioactive materials of the Bundesanstalt fuer Materialpruefung (BAM) is given. (RW/LH) [de

  4. Radiation Resistance Test of Wireless Sensor Node and the Radiation Shielding Calculation

    Energy Technology Data Exchange (ETDEWEB)

    Li, Liqan; Sur, Bhaskar [Atomic Energy of Canada Limited, Ontario (Canada); Wang, Quan [University of Western Ontario, Ontario (Canada); Deng, Changjian [The University of Electronic Science and Technology, Chengdu (China); Chen, Dongyi; Jiang, Jin [Applied Physics Branch, Ontario (Korea, Republic of)

    2014-08-15

    A wireless sensor network (WSN) is being developed for nuclear power plants. Amongst others, ionizing radiation resistance is one essential requirement for WSN to be successful. This paper documents the work done in Chalk River Laboratories of Atomic Energy of Canada Limited (AECL) to test the resistance to neutron and gamma radiation of some WSN nodes. The recorded dose limit that the nodes can withstand before being damaged by the radiation is compared with the radiation environment inside a typical CANDU (CANada Deuterium Uranium) power plant reactor building. Shielding effects of polyethylene, cadmium and lead to neutron and gamma radiations are also analyzed using MCNP simulation. The shielding calculation can be a reference for the node case design when high dose rate or accidental condition (like Fukushima) is to be considered.

  5. Compilation of radiation damage test data. II

    International Nuclear Information System (INIS)

    Schoenbacher, H.; Stolarz-Izycka, A.

    1979-01-01

    This report summarizes radiation damage test data on thermosetting and thermoplastic resins, with the main emphasis on epoxy resins used for magnet coil insulations. Also, other materials such as polyesters, phenolics, polyurethanes, silicones, etc., are represented. The materials have been irradiated in a nuclear reactor to integrated absorbed doses between 5x10 6 Gy and 1x10 8 Gy. The mechanical properties, e.g. the flexural strength, deflection at break, and tangent modulus of elasticity, have been measured on irradiated and non-irradiated samples. The results are given as variation of these parameters versus absorbed dose and are presented in the form of tables and graphs. The tested materials are catalogued in alphabetical order. (Auth.)

  6. Irradiation tests of radiation resistance optical fibers for fusion diagnostic application

    Science.gov (United States)

    Kakuta, Tsunemi; Shikama, Tatsuo; Nishitani, Takeo; Yamamoto, Shin; Nagata, Shinji; Tsuchiya, Bun; Toh, Kentaro; Hori, Junichi

    2002-11-01

    To promote development of radiation-resistant core optical fibers, the ITER-EDA (International Thermonuclear Experimental Reactor-Engineering Design Activity) recommended carrying out international round-robin irradiation tests of optical fibers to establish a reliable database for their applications in the ITER plasma diagnostics. Ten developed optical fibers were irradiation-tested in a Co-60 gamma cell, a Japan Materials Testing Reactor (JMTR). Also, some of them were irradiation tested in a fast neutron irradiation facility of FNS (Fast Neutron Source), especially to study temperature dependence of neutron-associated irradiation effects. Included were several Japanese fluorine doped fibers and one Japanese standard fiber (purified and undoped silica core), as well as seven Russian fibers. Some of Russian fibers were drawn by Japanese manufactures from Russian made pre-form rods to study effects of manufacturing processes to radiation resistant properties. The present paper will describe behaviors of growth of radiation-induced optical transmission loss in the wavelength range of 350-1750nm. Results indicate that role of displacement damages by fast neutrons are very important in introducing permanent optical transmission loss. Spectra of optical transmission loss in visible range will depend on irradiation temperatures and material parameters of optical fibers.

  7. Radiation effects in ice: New results

    International Nuclear Information System (INIS)

    Baragiola, R.A.; Fama, M.; Loeffler, M.J.; Raut, U.; Shi, J.

    2008-01-01

    Studies of radiation effects in ice are motivated by intrinsic interest and by applications in astronomy. Here we report on new and recent results on radiation effects induced by energetic ions in ice: amorphization of crystalline ice, compaction of microporous amorphous ice, electrostatic charging and dielectric breakdown and correlated structural/chemical changes in the irradiation of water-ammonia ices

  8. Testing the effects from dark radiation

    International Nuclear Information System (INIS)

    Zhang Yi; Gong Yungui

    2013-01-01

    In this paper, the effects of dark radiation (DR) are tested. Theoretically, the phase-space analysis method is applied to check whether the model is consist with the history of our universe which shows positive results. Observationally, by using the observational data (SuperNovae Legacy Survey (SNLS), Wilkinson Microwave Anisotropy Probe 9 Years Result (WMAP9), Planck First Data Release (PLANCK), baryon acoustic oscillations (BAO), Hubble parameter data (H(z)) and Big Bang nucleosynthesis (BBN)), the DR is found to have the effect of wiping out the tension between the SNLS data and the other data in a flat ΛCDM model. The effects of DR also make the best fit value of N eff slightly larger than 3.04. (paper)

  9. Radiation tests at cryogenic temperature on selected organic materials for LHC

    International Nuclear Information System (INIS)

    Humer, K.; Weber, H.W.; Szeless, B.; Tavlet, M.

    1997-01-01

    Future multi-TeV particle accelerators like the CERN Large Hadron Collider (LHC) will use superconducting magnets in which organic materials will be exposed to high radiation levels at temperatures as low as 2 K. A representative selection of organic materials comprising insulating films, cable insulations, epoxy resins and composites were exposed to neutron and gamma radiation of a nuclear reactor. Depending on the type of materials, the integrated radiation doses varied between 180 kGy and 155 MGy. During irradiation, the samples were kept close to the boiling temperature of liquid nitrogen, i.e. at 80 K, and thereafter stored in liquid nitrogen and transferred at the same temperature into the testing device for measurement of tensile and flexural strength. Tests were carried out on the same materials at similar dose rates at room temperature, and the results are compared with the ones obtained at cryogenic temperature. They show that within the selected dose range, a number of organic materials are suitable for use in radiation fields of the LHC at cryogenic temperature

  10. Commercial Off-The-Shelf (COTS) Graphics Processing Board (GPB) Radiation Test Evaluation Report

    Science.gov (United States)

    Salazar, George A.; Steele, Glen F.

    2013-01-01

    Large round trip communications latency for deep space missions will require more onboard computational capabilities to enable the space vehicle to undertake many tasks that have traditionally been ground-based, mission control responsibilities. As a result, visual display graphics will be required to provide simpler vehicle situational awareness through graphical representations, as well as provide capabilities never before done in a space mission, such as augmented reality for in-flight maintenance or Telepresence activities. These capabilities will require graphics processors and associated support electronic components for high computational graphics processing. In an effort to understand the performance of commercial graphics card electronics operating in the expected radiation environment, a preliminary test was performed on five commercial offthe- shelf (COTS) graphics cards. This paper discusses the preliminary evaluation test results of five COTS graphics processing cards tested to the International Space Station (ISS) low earth orbit radiation environment. Three of the five graphics cards were tested to a total dose of 6000 rads (Si). The test articles, test configuration, preliminary results, and recommendations are discussed.

  11. A scintillation testing technology at a viewpoint of optical test. At a memory of winning of the Radiation Prize (Prize of Encouragement)

    International Nuclear Information System (INIS)

    Maekawa, Tatsuyuki

    2000-01-01

    In a 'summer school' held at Matsushima, a series of developmental results had been introduced on a wavelength shift type beta-ray detector and others recently progressed by author at a viewpoint of 'new reconsideration on scintillation testing, one of the oldest radiation testing technology for an optical testing'. As a chance to write this theme again was obtained at present, here were introduced on trial and errors, backgrounds on ideas, pains for trial production and so forth at a process of putting together them for actual technologies and products under combining a series of ideas with their needs. Here were newly introduced on developmental backgrounds, points for practicability, and so forth on optical radiation testing technology which had been developed by authors. By upgrading of radiation resistance on the optical fibers themselves, developments for not only radiation testing but also instrumentation in storage vessel specific to nuclear instrumentation are considered in future. And, some findings on new elements and techniques, such as application of radiation to refractive index change due to much minute exotherm, application of Cherenkov phenomenon in glass, fiber grating and interference test assembles a minute diffraction lattice into a core, and so forth are found recently, which will be expected for their future developments. (G.K.)

  12. A scintillation testing technology at a viewpoint of optical test. At a memory of winning of the Radiation Prize (Prize of Encouragement)

    Energy Technology Data Exchange (ETDEWEB)

    Maekawa, Tatsuyuki [Toshiba Corp., Kawasaki, Kanagawa (Japan)

    2000-04-01

    In a 'summer school' held at Matsushima, a series of developmental results had been introduced on a wavelength shift type beta-ray detector and others recently progressed by author at a viewpoint of 'new reconsideration on scintillation testing, one of the oldest radiation testing technology for an optical testing'. As a chance to write this theme again was obtained at present, here were introduced on trial and errors, backgrounds on ideas, pains for trial production and so forth at a process of putting together them for actual technologies and products under combining a series of ideas with their needs. Here were newly introduced on developmental backgrounds, points for practicability, and so forth on optical radiation testing technology which had been developed by authors. By upgrading of radiation resistance on the optical fibers themselves, developments for not only radiation testing but also instrumentation in storage vessel specific to nuclear instrumentation are considered in future. And, some findings on new elements and techniques, such as application of radiation to refractive index change due to much minute exotherm, application of Cherenkov phenomenon in glass, fiber grating and interference test assembles a minute diffraction lattice into a core, and so forth are found recently, which will be expected for their future developments. (G.K.)

  13. In situ radiation measurements at the former Soviet Nuclear Test Site

    International Nuclear Information System (INIS)

    Tipton, W.J.

    1996-06-01

    A team from the Remote Sensing Laboratory conducted a series of in situ radiological measurements at the former Soviet Nuclear Test Site near Semipalatinsk, Kazakhstan, during the period of July 21-30, 1994. The survey team measured the terrestrial gamma radiation at selected areas on the site to determine the levels of natural and man-made radiation. The survey was part of a cooperative effort between the United States team and teams of radiation scientists from the National Nuclear Center of the Republic of Kazakhstan and the V.G. Khlopin Radium Institute in St. Petersburg, Russia. In addition to in situ radiation measurements made by the United States and Russian teams, soil samples were collected and analyzed by the Russian and Kazakhstani teams. All teams conducted their measurements at ten locations within the test site. The United States team also made a number of additional measurements to locate and verify the positions of three potential fallout plumes containing plutonium contamination from nonnuclear tests. In addition, the United States team made several measurements in Kurchatov City, the housing area used by personnel and their families who work(ed) at the test sites. Comparisons between the United States and Russian in situ measurements and the soil sample results are presented as well as comparisons with a Soviet aerial survey conducted in 1990-1991. The agreement between the different types of measurements made by all three countries was quite good

  14. Radiation flaw detector for testing non-uniform surface bodies of revolution

    International Nuclear Information System (INIS)

    Valevich, M.I.

    1984-01-01

    Radiation flaw detector for testing bodies of revolution with non-uniform surface, welded joints, etc., based on spatial filtration and differentiation of ionizing radiation flux has been described. The calculation of the most important unit of flaw detector - integrators - is made. Experimental studies of the sensitivity have shown, that the radiation flaw detector can be used for rapid testing of products with the sensitivity comparable with the sensitivity of radiographic testing of steel

  15. Professional exposure to ionizing radiation some hematological cytomorfological and immunological tests

    International Nuclear Information System (INIS)

    Trajkovicj, M.; Veljkovicj, D.; Barjaktarevicj, N.; Kosticj, V.; Brkicj, S.; Pendicj, B.

    1977-01-01

    The paper represents results of some hematological, cytomorphological and immunological tests for persons professionally exposed to ionizing radiations. Number of leucocytes, neutrophil granulocytes and lymphocytes do not show statistically significant differences between the exposed and control groups. An increase of binucleated lymphocytes and chromosome abberations is registered, the second being statistically significant in comparison to the control group. A small depression in cellular immunity is observed for several persons working with ionizing radiation for a longer period

  16. Chemical compatibility screening test results

    International Nuclear Information System (INIS)

    Nigrey, P.J.; Dickens, T.G.

    1997-12-01

    A program for evaluating packaging components that may be used in transporting mixed-waste forms has been developed and the first phase has been completed. This effort involved the screening of ten plastic materials in four simulant mixed-waste types. These plastics were butadiene-acrylonitrile copolymer rubber, cross-linked polyethylene (XLPE), epichlorohydrin rubber, ethylene-propylene rubber (EPDM), fluorocarbon (Viton or Kel-F), polytetrafluoroethylene, high-density polyethylene (HDPE), isobutylene-isoprene copolymer rubber (butyl), polypropylene, and styrene-butadiene rubber (SBR). The selected simulant mixed wastes were (1) an aqueous alkaline mixture of sodium nitrate and sodium nitrite; (2) a chlorinated hydrocarbon mixture; (3) a simulant liquid scintillation fluid; and (4) a mixture of ketones. The testing protocol involved exposing the respective materials to 286,000 rads of gamma radiation followed by 14-day exposures to the waste types at 60 degrees C. The seal materials were tested using vapor transport rate (VTR) measurements while the liner materials were tested using specific gravity as a metric. For these tests, a screening criterion of 0.9 g/hr/m 2 for VTR and a specific gravity change of 10% was used. Based on this work, it was concluded that while all seal materials passed exposure to the aqueous simulant mixed waste, EPDM and SBR had the lowest VTRs. In the chlorinated hydrocarbon simulant mixed waste, only Viton passed the screening tests. In both the simulant scintillation fluid mixed waste and the ketone mixture simulant mixed waste, none of the seal materials met the screening criteria. For specific gravity testing of liner materials, the data showed that while all materials with the exception of polypropylene passed the screening criteria, Kel-F, HDPE, and XLPE offered the greatest resistance to the combination of radiation and chemicals

  17. SP-100 GES/NAT radiation shielding systems design and development testing

    International Nuclear Information System (INIS)

    Disney, R.K.; Kulikowski, H.D.; McGinnis, C.A.; Reese, J.C.; Thomas, K.; Wiltshire, F.

    1991-01-01

    Advanced Energy Systems (AES) of Westinghouse Electric Corporation is under subcontract to the General Electric Company to supply nuclear radiation shielding components for the SP-100 Ground Engineering System (GES) Nuclear Assembly Test to be conducted at Westinghouse Hanford Company at Richland, Washington. The radiation shielding components are integral to the Nuclear Assembly Test (NAT) assembly and include prototypic and non-prototypic radiation shielding components which provide prototypic test conditions for the SP-100 reactor subsystem and reactor control subsystem components during the GES/NAT operations. W-AES is designing three radiation shield components for the NAT assembly; a prototypic Generic Flight System (GFS) shield, the Lower Internal Facility Shield (LIFS), and the Upper Internal Facility Shield (UIFS). This paper describes the design approach and development testing to support the design, fabrication, and assembly of these three shield components for use within the vacuum vessel of the GES/NAT. The GES/NAT shields must be designed to operate in a high vacuum which simulates space operations. The GFS shield and LIFS must provide prototypic radiation/thermal environments and mechanical interfaces for reactor system components. The NAT shields, in combination with the test facility shielding, must provide adequate radiation attenuation for overall test operations. Special design considerations account for the ground test facility effects on the prototypic GFS shield. Validation of the GFS shield design and performance will be based on detailed Monte Carlo analyses and developmental testing of design features. Full scale prototype testing of the shield subsystems is not planned

  18. Low level radiation testing of micro-electronic components. Pt. 1

    International Nuclear Information System (INIS)

    Farren, J.; Stephen, J.H.; Mapper, D.; Sanderson, T.K.; Hardman, M.

    1984-05-01

    A review of the existing literature has been carried out, dealing with the current technology relating to low level radiation testing of microelectronic devices, as used in space satellite systems. After consideration of the space radiation environment, the general effects of cosmic radiation on MOSFET structures and other MOS devices have been assessed. The important aspect of annealing phenomena in relation to gamma-ray induced damage has also been reviewed in detail. The experimental and theoretical aspects of radiation testing have been assessed, with particular reference to the Harwell LORAD low level irradiation test facility. In addition, a review of modern dosimetry methods has been carried out, with specific regard to the problems of accurately measuring low radiation fields (1 to 10 R/hour) over periods of many months. Finally, a detailed account of the proposed experimental programme to be carried out in the LORAD facility is presented, and aspects of the experimental set-up discussed. The particular types of test circuits to be studied are dealt with, and full consideration is given to the various CMOS memory devices of special interest in the ESA space satellite programme. (author)

  19. Eurados trial performance test for personal dosemeters for external beta radiation

    DEFF Research Database (Denmark)

    Christensen, P.; Bordy, J.M.; Ambrosi, P.

    2001-01-01

    On the initiative of the European Dosimetry Group (EURADOS) action group 'Harmonisation and Dosimetric Quality Assurance in Individual Monitoring for External Radiation' a trial performance test for whole-body and extremity personal dosemeters broadly representative of those in use in the EU...... the results obtained from the exercise. In particular, based on the replies to a questionnaire issued to each participant, the results are analysed in relation to important design characteristics of the dosemeters taking part in the test....

  20. IPRT polarized radiative transfer model intercomparison project - Three-dimensional test cases (phase B)

    Science.gov (United States)

    Emde, Claudia; Barlakas, Vasileios; Cornet, Céline; Evans, Frank; Wang, Zhen; Labonotte, Laurent C.; Macke, Andreas; Mayer, Bernhard; Wendisch, Manfred

    2018-04-01

    Initially unpolarized solar radiation becomes polarized by scattering in the Earth's atmosphere. In particular molecular scattering (Rayleigh scattering) polarizes electromagnetic radiation, but also scattering of radiation at aerosols, cloud droplets (Mie scattering) and ice crystals polarizes. Each atmospheric constituent produces a characteristic polarization signal, thus spectro-polarimetric measurements are frequently employed for remote sensing of aerosol and cloud properties. Retrieval algorithms require efficient radiative transfer models. Usually, these apply the plane-parallel approximation (PPA), assuming that the atmosphere consists of horizontally homogeneous layers. This allows to solve the vector radiative transfer equation (VRTE) efficiently. For remote sensing applications, the radiance is considered constant over the instantaneous field-of-view of the instrument and each sensor element is treated independently in plane-parallel approximation, neglecting horizontal radiation transport between adjacent pixels (Independent Pixel Approximation, IPA). In order to estimate the errors due to the IPA approximation, three-dimensional (3D) vector radiative transfer models are required. So far, only a few such models exist. Therefore, the International Polarized Radiative Transfer (IPRT) working group of the International Radiation Commission (IRC) has initiated a model intercomparison project in order to provide benchmark results for polarized radiative transfer. The group has already performed an intercomparison for one-dimensional (1D) multi-layer test cases [phase A, 1]. This paper presents the continuation of the intercomparison project (phase B) for 2D and 3D test cases: a step cloud, a cubic cloud, and a more realistic scenario including a 3D cloud field generated by a Large Eddy Simulation (LES) model and typical background aerosols. The commonly established benchmark results for 3D polarized radiative transfer are available at the IPRT website (http

  1. Identification of Radiation Effects on Carcinogenic Food Estimated by Ames Test

    International Nuclear Information System (INIS)

    Afifi, M.; Eid, I.; El - Nagdy, M.; Zaher, R.; Abd El-Karem, H.; Abd EL Karim, A.

    2016-01-01

    A major concern in studies related to carcinogenesis is the exposure to the exogenous carcinogens that may occur in food in both natural and polluted human environments. The purpose of the present study is to examine some of food products by Ames test to find out if food products carcinogenic then expose food to gamma radiation to find out the effect of radiation on it as a treatment. In this study, the food samples were examined by Ames test (Salmonella typhimurium mutagenicity test) to find out that a food product could be carcinogenic or highly mutated. Testing of chemicals for mutagenicity is based on the knowledge that a substance which is mutagenic in the bacterium is more likely than not to be a carcinogen in laboratory animals, and thus , by extension, present a risk of cancer to humans. After that food products that showed mutagenicity exposed to gamma radiation at different doses to examine the effect of gamma radiation on food products. This study represent γ radiation effect on carcinogenic food by using Ames test in the following steps: Detect food by Ames test using Salmonella typhimurium strains in which the colony count /plate for each food sample will show if food is slightly mutated or highly mutated or carcinogenic. If food is highly mutated or carcinogenic with high number of colonies /plate, then the carcinogenic food or highly mutated food exposed to different doses of radiation The applied doses in this study were 0, 2.5, 5, and 10 (KGy). Detect the radiation effect on food samples by Ames test after irradiation. The study shows that mutated and carcinogenic food products estimated by Ames test could be treated by irradiation

  2. Confirmation of soil radiation damping from test versus analysis

    International Nuclear Information System (INIS)

    Eidinger, J.M.; Mukhim, G.S.; Desmond, T.P.

    1987-01-01

    The work was performed to demonstrate that soil-structure interaction effects for nuclear plant structures can be accurately (and conservatively) predicted using the finite element or soil spring methods of soil-structure interaction analysis. Further, the work was done to investigate the relative importance of soil radiation versus soil material damping in the total soil damping analytical treatment. The analytical work was benchmarked with forced vibration tests of a concrete circular slab resting on the soil surface. The applied loading was in the form of a suddenly applied pulse load, or snapback. The measured responses of the slap represent the free vibration of the slab after the pulse load has been applied. This simplifies the interpretation of soil damping, by the use of the logarithmic decay formulation. To make comparisons with the test results, the damping data calculated from the analytical models is also based on the logarithmic decay formulation. An attempt is made to differentiate the observed damped behavior of the concrete slab as being caused by soil radiation versus soil material damping. It is concluded that both the traditional soil radiation and material damping analytical simplifications are validated by the observed responses. It is concluded that arbitrary 'conservative' assumptions traditionally made in nuclear plant soil-structure interaction analyses are indeed arbitrary, and not born out by physical evidence. The amount of conservatism introduced by limiting total soil damping to values like 5% to 10% can be large. For the test slab sizes investigated, total soil damping is about 25%. For full size nuclear plant foundations, total soil damping is commonly in the 35% to 70% range. The authors suggest that full soil damping values (the combined radiation and material damping) should be used in the design, backfit and margin assessment of nuclear plants. (orig./HP)

  3. Advanced CMOS Radiation Effects Testing and Analysis

    Science.gov (United States)

    Pellish, J. A.; Marshall, P. W.; Rodbell, K. P.; Gordon, M. S.; LaBel, K. A.; Schwank, J. R.; Dodds, N. A.; Castaneda, C. M.; Berg, M. D.; Kim, H. S.; hide

    2014-01-01

    Presentation at the annual NASA Electronic Parts and Packaging (NEPP) Program Electronic Technology Workshop (ETW). The material includes an update of progress in this NEPP task area over the past year, which includes testing, evaluation, and analysis of radiation effects data on the IBM 32 nm silicon-on-insulator (SOI) complementary metal oxide semiconductor (CMOS) process. The testing was conducted using test vehicles supplied by directly by IBM.

  4. What do Patients Want From Their Radiation Oncologist? Initial Results From a Prospective Trial

    International Nuclear Information System (INIS)

    Bhatnagar, Ajay K.; Land, Stephanie R.; Shogan, Alyson; Rodgers, Edwin E.; Heron, Dwight E.; Flickinger, John C.

    2007-01-01

    Purpose: To assess patients' initial physician preferences using a newly developed instrument. Methods and Materials: A total of 182 patients with a primary diagnosis of prostate, breast, or lung cancer referred for consultation to University of Pittsburgh Cancer Institute Department of Radiation Oncology enrolled in our institutional review board-approved protocol. All patients completed patient preference instrument surveys before meeting their radiation oncologist. Survey responses to 10 statements were categorized into three groups (agree, neutral, or disagree), and the association of survey responses by cancer site was tested with chi-squared tests. Results: Ninety-nine percent of all patients preferred to be addressed by their first name in encounters with their radiation oncologist. There were significant associations of Item 3 (hand holding) with gender (p = 0.039) and education (p = 0.028). The responses to Item 5, a statement that patients would feel uncomfortable if the radiation oncologist offered to hug them at the end of treatment, was significantly associated with disease site (p < 0.0001). Further analysis was performed for Item 5 and revealed that the male lung cancer patients had a much higher rate of disagreement with Item 5 compared with prostate cancer patients (37% vs. 18%). Conclusions: Results of this study may afford greater insight and foster better understanding of what patients want from their radiation oncologist. For breast, lung, and prostate cancer patients, initial preferences for their radiation oncologist are generally similar, according to this tool. However, there are important difference among cancer sites (and gender) regarding physical contact at the end of treatment

  5. Monte Carlo simulation of the sequential probability ratio test for radiation monitoring

    International Nuclear Information System (INIS)

    Coop, K.L.

    1984-01-01

    A computer program simulates the Sequential Probability Ratio Test (SPRT) using Monte Carlo techniques. The program, SEQTEST, performs random-number sampling of either a Poisson or normal distribution to simulate radiation monitoring data. The results are in terms of the detection probabilities and the average time required for a trial. The computed SPRT results can be compared with tabulated single interval test (SIT) values to determine the better statistical test for particular monitoring applications. Use of the SPRT in a hand-and-foot alpha monitor shows that the SPRT provides better detection probabilities while generally requiring less counting time. Calculations are also performed for a monitor where the SPRT is not permitted to the take longer than the single interval test. Although the performance of the SPRT is degraded by this restriction, the detection probabilities are still similar to the SIT values, and average counting times are always less than 75% of the SIT time. Some optimal conditions for use of the SPRT are described. The SPRT should be the test of choice in many radiation monitoring situations. 6 references, 8 figures, 1 table

  6. Status and update of the National Ignition Facility radiation effects testing program

    International Nuclear Information System (INIS)

    Davis, J F; Serduke, F J; Wuest, C R.

    1998-01-01

    We are progressing in our efforts to make the National Ignition Facility (NIF) available to the nation as a radiation effects simulator to support the Services needs for nuclear hardness and survivability testing and validation. Details of our program were summarized in a paper presented at the 1998 HEART Conference [1]. This paper describes recent activities and updates plans for NIF radiation effects testing. research. Radiation Effects Testing

  7. Compilation of radiation damage test data part III: materials used around high-energy accelerators

    CERN Document Server

    Beynel, P; Schönbacher, H; CERN. Geneva

    1982-01-01

    For pt.II see CERN report 79-08 (1979). This handbook gives the results of radiation damage tests on various engineering materials and components intended for installation in radiation areas of the CERN high-energy particle accelerators. It complements two previous volumes covering organic cable-insulating materials and thermoplastic and thermosetting resins.

  8. Field Lysimeter Investigations - test results: Low-Level Waste Data Base Development Program: Test results for fiscal years 1994-1995

    International Nuclear Information System (INIS)

    McConnell, J.W. Jr.; Rodgers, R.D.; Hilton, L.D.; Neilson, R.M. Jr.

    1996-06-01

    The Field Lysimeter Investigations: Low-Level Waste Data Base Development Program, funded by the U.S. Nuclear Regulatory Commission (NRC), is (1) studying the degradation effects in EPICOR-II organic ion-exchange resins caused by radiation, (2) examining the adequacy of test procedures recommended in the Branch Technical Position on Waste Form to meet the requirements of 10 CFR 61 using solidified EPICOR-II resins, (3) obtaining performance information on solidified EPICOR-II ion-exchange resins in a disposal environment, and (4) determining the condition of EPICOR-II liners. Results of the final 2 (10 total) years of data acquisition from operation of the field testing are presented and discussed. During the continuing field testing, both portland type I-II cement and Dow vinyl ester-styrene waste forms are being tested in lysimeter arrays located at Argonne National Laboratory-East in Illinois and at Oak Ridge National Laboratory. The experimental equipment is described and results of waste form characterization using tests recommended by the NRC's open-quotes Technical Position on Waste Formclose quotes are presented. The study is designed to provide continuous data on nuclide release and movement, as well as environmental conditions, over a 20-year period. At the end of the tenth year, the experiment was closed down. Examination of soil and waste forms is planned to be conducted next and will be reported later

  9. Investigation of the dynamics of radiation pollution at the former Semipalatinsk nuclear test site

    International Nuclear Information System (INIS)

    Belyashov, L.; Yushkov, A.; Grinshtein, Yu.; Makarenko, N.

    1996-01-01

    Main Tasks: - To perform aerial gamma-spectrometric shooting of the whole territory of the Semipalatinsk test site in a scale 1:200,000 with registration of the total spectrum; - The same in a scale 1:10,000 for the Balapan region; - To construct the physical-mathematical forecasting models of the dynamics of radionuclide contamination at the STS area. Scientific and Technical Means, Methods, Approaches - Aerial gamma-spectroscopy on a base of the crystals of Iodine Sodium, activated by Thallium, volume 25 I, with registration of the total spectrum; - A set of the software and computational means along with the data bases; - The aerial gamma-spectrometric standard testing site 'irtysh' - for Cesium-137 and the testing sites 'Kora' and 'Aidarly' - for natural radio-nuclides; - Software and computational means for development of physical-mathematical models; - Expedition equipment for ground testing in the points of the most prominent radiation anomalies. Expected Results - The second temporal point, with an interval of five years, on a state of radiation fields at the STS in two scales. Forecasting models for space-time evolution of radiation fields at the STS. - The results of comparison between the aerial and ground measurements

  10. Compilation of radiation damage test data cable insulating materials

    CERN Document Server

    Schönbacher, H; CERN. Geneva

    1979-01-01

    This report summarizes radiation damage test data on commercially available organic cable insulation and jacket materials: ethylene- propylene rubber, Hypalon, neoprene rubber, polyethylene, polyurethane, polyvinylchloride, silicone rubber, etc. The materials have been irradiated in a nuclear reactor to integrated absorbed doses from 5*10/sup 5/ to 5*10/sup 6/ Gy. Mechanical properties, e.g. tensile strength, elongation at break, and hardness, have been tested on irradiated and non-irradiated samples. The results are presented in the form of tables and graphs, to show the effect of the absorbed dose on the measured properties. (13 refs).

  11. Operation of radiation monitoring system in radwaste form test facility

    International Nuclear Information System (INIS)

    Ryu, Young Gerl; Kim, Ki Hong; Lee, Jae Won; Kwac, Koung Kil

    1998-08-01

    RWFTF (RadWaste Form Test Facility) must have a secure radiation monitoring system (RMS) because of having a hot-cell capable of handling high radioactive materials. And then in controlled radiation zone, which is hot-cell and its maintenance and operation / control room, area dose rate, radioactivities in air-bone particulates and stack, and surface contamination are monitored continuously. For the effective management such as higher utilization, maintenance and repair, the status of this radiation monitoring system, the operation and characteristics of all kinds of detectors and other parts of composing this system, and signal treatment and its evaluation were described in this technical report. And to obtain the accuracy detection results and its higher confidence level, the procedure such as maintenance, functional check and system calibration were established and appended to help the operation of RMS. (author). 6 tabs., 30 figs

  12. Offsite environmental monitoring report: Radiation monitoring around United States nuclear test areas

    International Nuclear Information System (INIS)

    1990-01-01

    This report describes the Offsite Radiation Safety Program conducted during 1990 by the Environmental Protection Agency's (EPA's) Environmental Monitoring Systems Laboratory -- Las Vegas. This laboratory operates an environmental radiation monitoring program in the region surrounding the Nevada Test Site (NTS) and at former test sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The surveillance program is designed to measure levels and trends of radioactivity, if present, in the environment surrounding testing areas to ascertain whether current radiation levels and associated doses to the general public are in compliance with existing radiation protection standards. The surveillance program additionally has the responsibility to take action to protect the health and well being of the public in the event of any accidental release of radioactive contaminants. Offsite levels of radiation and radioactivity are assessed by sampling milk, water, and air; by deploying thermoluminescent dosimeters (TLDs) and using pressurized ion chambers (PICs); and by biological monitoring of animals, food crops, and humans. Personnel with mobile monitoring equipment are placed in areas downwind from the test site prior to each nuclear weapons test to implement protective actions, provide immediate radiation monitoring, and obtain environmental samples rapidly after any occurrence of radioactivity release

  13. Preliminary Flight Results of the Microelectronics and Photonics Test Bed: NASA DR1773 Fiber Optic Data Bus Experiment

    Science.gov (United States)

    Jackson, George L.; LaBel, Kenneth A.; Marshall, Cheryl; Barth, Janet; Seidleck, Christina; Marshall, Paul

    1998-01-01

    NASA Goddard Spare Flight Center's (GSFC) Dual Rate 1773 (DR1773) Experiment on the Microelectronic and Photonic Test Bed (MPTB) has provided valuable information on the performance of the AS 1773 fiber optic data bus in the space radiation environment. Correlation of preliminary experiment data to ground based radiation test results show the AS 1773 bus is employable in future spacecraft applications requiring radiation tolerant communication links.

  14. Isotope detectors and radiation detectors for test reliability techniqui. A preliminary project

    International Nuclear Information System (INIS)

    Christell, R.

    1977-03-01

    A survey is done of small and simple components for use as detectors for ionizing radiation, as well as different methods and components producing images of radiation fields based on position sensitive detectors. The investigation has resulted in a system for detection of stones in wood. In a second project isotope excited x ray fluorescence has been used for analysis of material resulting from wear of mechanical components. A facility for analysis has been built and test analysis has been performed. Methods for continous wear control with possibility to forecast breakdowns have been investigated. (K.K.)

  15. Characterization of radiation effects in 65 nm digital circuits with the DRAD digital radiation test chip

    International Nuclear Information System (INIS)

    Casas, L.M. Jara; Ceresa, D.; Kulis, S.; Christiansen, J.; Francisco, R.; Miryala, S.; Gnani, D.

    2017-01-01

    A Digital RADiation (DRAD) test chip has been specifically designed to study the impact of Total Ionizing Dose (TID) (<1 Grad) and Single Event Upset (SEU) on digital logic gates in a 65 nm CMOS technology. Nine different versions of standard cell libraries are studied in this chip, basically differing in the device dimensions, V t flavor and layout of the device. Each library has eighteen test structures specifically designed to characterize delay degradation and power consumption of the standard cells. For SEU study, a dedicated test structure based on a shift register is designed for each library. TID results up to 500 Mrad are reported.

  16. LWR surveillance dosimetry improvement program: PSF metallurgical blind test results

    International Nuclear Information System (INIS)

    Kam, F.B.K.; Stallmann, F.W.; Guthrie, G.; McElroy, W.N.

    1985-01-01

    The ORR-PSF benchmark experiment was designed to simulate the surveillance capsule-pressure vessel configuration in power reactors and to test the validity of procedures which determine the radiation damage in the vessel from test results in the surveillance capsule. The PSF metallurgical blind test was initiated to give participants an opportunity to test their current embrittlement prediction methodologies. Experimental results were withheld from the participants except for the type of information which is normally contained in surveillance reports. Preliminary analysis of the PSF metallurgical blind test results shows that: (1) current prediction methodologies, as used by the PSF Blind Test participants, are adequate, falling within +- 20 0 C of the measured values for Δ NDT. None of the different methods is clearly superior; (2) the proposed revision of Reg. Guide 1.99 (Rev. 2) gives a better representation of the fluence and chemistry dependency of Δ NDT than the current version (Rev. 1); and (3) fluence rate effects can be seen but not quantified. Fluence spectral effects are too small to be detectable in this experiment. (orig.)

  17. Offsite environmental monitoring report; radiation monitoring around United States nuclear test areas, Calendar Year 1996

    International Nuclear Information System (INIS)

    Davis, M.G.; Flotard, R.D.; Fontana, C.A.; Huff, P.A.; Maunu, H.K.; Mouck, T.L.; Mullen, A.A.; Sells, M.D.

    1997-08-01

    This report describes the Offsite Radiation Safety Program. This laboratory operated an environmental radiation monitoring program in the region surrounding the Nevada Test Site (NTS) and at former test sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The surveillance program is designed to measure levels and trends of radioactivity, if present, in the environment surrounding testing areas to ascertain whether current radiation levels and associated doses to the general public are in compliance with existing radiation protection standards. The surveillance program additionally has the responsibility to take action to protect the health and well being of the public in the event of any accidental release of radioactive contaminants. Offsite levels of radiation and radioactivity are assessed by sampling milk, water, and air; by deploying thermoluminescent dosimeters (TLDs); and using pressurized ionization chambers (PICs). No nuclear weapons testing was conducted in 1996 due to the continuing nuclear test moratorium. During this period, R and IE personnel maintained readiness capability to provide direct monitoring support if testing were to be resumed and ascertained compliance with applicable EPA, DOE, state, and federal regulations and guidelines. Comparison of the measurements and sample analysis results with background levels and with appropriate standards and regulations indicated that there was no airborne radioactivity from diffusion or resuspension detected by the various EPA monitoring networks surrounding the NTS. There was no indication of potential migration of radioactivity to the offsite area through groundwater and no radiation exposure above natural background was received by the offsite population. All evaluated data were consistent with previous data history

  18. Tests for radiation protection in X-Ray mammography room for professional and non-professional exposure

    International Nuclear Information System (INIS)

    Naidenov, I.; Skocheva, A.

    2006-01-01

    Full text: Control tests for radiation protection of medical diagnostic rooms in our country are based on the guidelines to the use of x-rays in medicine and on the basic safety standards for radiation protection. The mammography room tests are not supported by basic data (such as normal conditions for testing and secondary limits) which to allow the developing of methods as the case is with the conventional x-ray rooms. The material presents and discusses over the situation of the matter with the aim to find solution of the problem. In mammography units the space distribution of the dose field of the object scattering radiation is not symmetrical, the maximum being in a direction opposite to the primary beam. Control tests were made for stray radiation in major (in the plane of beam rotation) test points in five rooms with mammography units of different producers and generation, under angles of scattering from the direction of the beam of 900 (horizontal table - 0 deg projection) and 1630 (tilt table - 730 deg projection). The results on the stray radiation show up to four times higher values in the 730 projection, the remaining conditions being the same. Normalization to the week loading used in the shielding design, like the comparison with secondary limits as published in the available norms do not give unambiguous idea. It is advisable to use this projection in control tests for radiation protection and the values shall be compared with the secondary limits of the corresponding standard loading

  19. Beam test results of the irradiated Silicon Drift Detector for ALICE

    OpenAIRE

    Kushpil, S.; Crescio, E.; Giubellino, P.; Idzik, M.; Kolozhvari, A.; Kushpil, V.; Martinez, M. I.; Mazza, G.; Mazzoni, A.; Meddi, F.; Nouais, D.; Petracek, V.; Piemonte, C.; Rashevsky, A.; Riccati, L.

    2005-01-01

    The Silicon Drift Detectors will equip two of the six cylindrical layers of high precision position sensitive detectors in the ITS of the ALICE experiment at LHC. In this paper we report the beam test results of a SDD irradiated with 1 GeV electrons. The aim of this test was to verify the radiation tolerance of the device under an electron fluence equivalent to twice particle fluence expected during 10 years of ALICE operation.

  20. Benchmark results in radiative transfer

    International Nuclear Information System (INIS)

    Garcia, R.D.M.; Siewert, C.E.

    1986-02-01

    Several aspects of the F N method are reported, and the method is used to solve accurately some benchmark problems in radiative transfer in the field of atmospheric physics. The method was modified to solve cases of pure scattering and an improved process was developed for computing the radiation intensity. An algorithms for computing several quantities used in the F N method was done. An improved scheme to evaluate certain integrals relevant to the method is done, and a two-term recursion relation that has proved useful for the numerical evaluation of matrix elements, basic for the method, is given. The methods used to solve the encountered linear algebric equations are discussed, and the numerical results are evaluated. (M.C.K.) [pt

  1. Electrochromic Radiator Coupon Level Testing and Full Scale Thermal Math Modeling for Use on Altair Lunar Lander

    Science.gov (United States)

    Bannon, Erika T.; Bower, Chad E.; Sheth, Rubik; Stephan, Ryan

    2010-01-01

    In order to control system and component temperatures, many spacecraft thermal control systems use a radiator coupled with a pumped fluid loop to reject waste heat from the vehicle. Since heat loads and radiation environments can vary considerably according to mission phase, the thermal control system must be able to vary the heat rejection. The ability to "turn down" the heat rejected from the thermal control system is critically important when designing the system. Electrochromic technology as a radiator coating is being investigated to vary the amount of heat rejected by a radiator. Coupon level tests were performed to test the feasibility of this technology. Furthermore, thermal math models were developed to better understand the turndown ratios required by full scale radiator architectures to handle the various operation scenarios encountered during a mission profile for the Altair Lunar Lander. This paper summarizes results from coupon level tests as well as the thermal math models developed to investigate how electrochromics can be used to increase turn down ratios for a radiator. Data from the various design concepts of radiators and their architectures are outlined. Recommendations are made on which electrochromic radiator concept should be carried further for future thermal vacuum testing.

  2. Radiation effects testing at the 88-Inch Cyclotron at LBNL

    International Nuclear Information System (INIS)

    McMahan, Margaret A.; Koga, Rokotura

    2002-01-01

    The effects of ionizing particles on sensitive microelectronics is an important component of the design of systems as diverse as satellites and space probes, detectors for high energy physics experiments and even internet server farms. Understanding the effects of radiation on human cells is an equally important endeavor directed towards future manned missions in space and towards cancer therapy. At the 88-Inch Cyclotron at the Berkeley Laboratory, facilities are available for radiation effects testing (RET) with heavy ions and with protons. The techniques for doing these measurements and the advantages of using a cyclotron will be discussed, and the Cyclotron facilities will be compared with other facilities worldwide. RET of the same part at several facilities of varying beam energy can provide tests of the simple models used in this field and elucidate the relative importance of atomic and nuclear effects. The results and implications of such measurements will be discussed

  3. Design and development of semi-automatic radiation test and calibration facility

    International Nuclear Information System (INIS)

    Yadav, Ashok Kumar; Chouhan, V.K.; Narayan, Pradeep

    2008-01-01

    Semi-automatic gamma radiation test and calibration facility have been designed, developed and commissioned at Defence Laboratory Jodhpur (DLJ). The facility comprises of medium and high dose rate range setup using 30 Ci Cobalt-60 source, in a portable remotely operated Techops camera and a 15000 Ci 60 Co source in a Tele-therapy machine. The radiation instruments can be positioned at any desired position using a computer controlled positioner having three translational and one rotational motion. User friendly software helps in positioning the Device Under Test (DUT) at any desired dose rate or distance and acquire the data automatically. The servo and stepper motor controlled positioner helps in achieving the required precision and accuracy for the radiation calibration of the instruments. This paper describes the semi-automatic radiation test and calibration facility commissioned at DLJ. (author)

  4. Radiation Testing of Electronics for the CMS Endcap Muon System

    CERN Document Server

    INSPIRE-00070357; Celik, A.; Durkin, L.S.; Gilmore, J.; Haley, J.; Khotilovich, V.; Lakdawala, S.; Liu, J.; Matveev, M.; Padley, B.P.; Roberts, J.; Roe, J.; Safonov, A.; Suarez, I.; Wood, D.; Zawisza, I.

    2013-01-01

    The electronics used in the data readout and triggering system for the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) particle accelerator at CERN are exposed to high radiation levels. This radiation can cause permanent damage to the electronic circuitry, as well as temporary effects such as data corruption induced by Single Event Upsets. Once the High Luminosity LHC (HL-LHC) accelerator upgrades are completed it will have five times higher instantaneous luminosity than LHC, allowing for detection of rare physics processes, new particles and interactions. Tests have been performed to determine the effects of radiation on the electronic components to be used for the Endcap Muon electronics project currently being designed for installation in the CMS experiment in 2013. During these tests the digital components on the test boards were operating with active data readout while being irradiated with 55 MeV protons. In reactor tests, components were exposed to 30 years equivalent levels o...

  5. Radiation Belt Test Model

    Science.gov (United States)

    Freeman, John W.

    2000-10-01

    Rice University has developed a dynamic model of the Earth's radiation belts based on real-time data driven boundary conditions and full adiabaticity. The Radiation Belt Test Model (RBTM) successfully replicates the major features of storm-time behavior of energetic electrons: sudden commencement induced main phase dropout and recovery phase enhancement. It is the only known model to accomplish the latter. The RBTM shows the extent to which new energetic electrons introduced to the magnetosphere near the geostationary orbit drift inward due to relaxation of the magnetic field. It also shows the effects of substorm related rapid motion of magnetotail field lines for which the 3rd adiabatic invariant is violated. The radial extent of this violation is seen to be sharply delineated to a region outside of 5Re, although this distance is determined by the Hilmer-Voigt magnetic field model used by the RBTM. The RBTM appears to provide an excellent platform on which to build parameterized refinements to compensate for unknown acceleration processes inside 5Re where adiabaticity is seen to hold. Moreover, built within the framework of the MSFM, it offers the prospect of an operational forecast model for MeV electrons.

  6. Analysis of the X-ray microbeam test result of the flash memories

    International Nuclear Information System (INIS)

    Yan Yihua; Ding Lili; Chen Wei; Guo Hongxia; Guo Xiaoqiang; Lin Dongsheng; Zhang Keying; Zhang Fengqi; Deng Yuliang; Fan Ruyu

    2013-01-01

    Background: The failure phenomenon is difficult to analyze for the flash memories when the whole chip is exposed to irradiation since both the memory array and the peripheral circuits might be degraded. Purpose: In order to detect the radiation susceptibility and corresponding phenomenon of the related circuits that included in the flash memories, the X-ray microbeam is used as the radiation source instead of 60 Co. Methods: The failure phenomenon is studied respectively when the memory array, decoder circuits, the charge pump circuits as well as the I/O circuits are exposed to radiation. The errors are mapped according to the logical address and the failure mechanism is analyzed based on the circuits. Results: Irradiated on the memory .array win lead to regularly distributed 0→1 bit flips, while only 1→0 are found when the row decoder is under exposure. Degradation of the charge pump circuits would lead to the erase/program functional failure. Conclusions: The results suggest that the X-ray microbeam radiation test is a good method for detecting the radiation susceptibility of the integrated circuits that contains lots of circuit modules. (authors)

  7. Irradiation tests of critical components for remote handling system in gamma radiation environment

    International Nuclear Information System (INIS)

    Obara, Kenjiro; Kakudate, Satoshi; Oka, Kiyoshi

    1996-03-01

    This report covers the gamma ray irradiation tests according to the Agreement of ITER R and D Task (T35) in 1994 and describes radiation hardness of the standard components for the ITER remote handling system which are categorized into the robotics (Subtask-1), the viewing system (Subtask-2) and the common components (Subtask-3). The gamma ray irradiation tests have been conducted using No.2 and No.3 cells at the cobalt building of Takasaki Establishment in JAERI. The radiation source is cobalt sixty (Co-60), and the maximum dose rate of No.2 and No.3 cells is about 1x10 6 R/h and 2x10 6 R/h, respectively. The environmental conditions of the irradiation tests are described below and all of components excepting electrical wires have been tested in the No.2 cell. [No.2 cell : Atmosphere and ambient temperature No.3 cell : Nitrogen gas and 250degC] As a whole, many of components have been irradiated up to the rated dose of around 1x10 10 rads and the following main results are obtained. The developed AC servo motor and periscope for radiation use have shown excellent durability with the radiation hardness tolerable for more than 10 9 rads. An electrical connector compatible with remote operation has also shown no degradation of electrical characteristics after the irradiation of 10 10 rads. As for polyimide insulated wires, the mechanical and electrical characteristics are not degradated after the irradiation of 10 9 rads and more radiation hardness can be expected than the anticipation. On the contrary, standard position sensors such as rotary encoder show extremely low radiation hardness and further efforts have to be made for improvements. (J.P.N.)

  8. Prospective evaluation of the effect of ionizing radiation on the bladder tumor-associated (BTA) urine test

    International Nuclear Information System (INIS)

    Crane, Christopher H.; Clark, Maureen M.; Bissonette, Eric A.; Theodorescu, Dan

    1999-01-01

    Purpose: To prospectively evaluate the effect of ionizing radiation on the results of the bladder tumor-associated antigen (BTA) test. By examining this question, we sought to determine its potential use as a monitoring test for the detection of recurrent transitional carcinoma of the bladder in patients who have received prior radiotherapy for bladder preservation. Materials and Methods: Between February 1996 and April 1997, 18 patients with nonbladder pelvic malignancies and no history of bladder cancer, received irradiation to the bladder. These patients were prospectively evaluated using the BTA test at the end of the external-beam radiation (EBRT) and at 3-month follow-up intervals. Urine cytology was analyzed in 16 of the 18 patients at the end of EBRT. A median of 3 separate measurements were made (range 1-6) on each patient. The median dose of EBRT was 50.4 Gy (range 30-68Gy). Seven patients underwent brachytherapy as part of their treatment course. BTA results and time intervals were recorded and analyzed using univariate and Kaplan-Meyer methodologies. Results: A total of 10 (56%) of the 18 patients had a positive BTA test at some time following completion of EBRT. Of the 10 positive tests, 9 returned to negative in a median of 42 weeks from completion of EBRT. Treatment with chemotherapy, brachytherapy, calculated bladder dose, and total external beam dose did not significantly influence either the number of positive tests or the time to resolution of the positive test in this small group of patients. All screened urine samples were negative for malignant cells and 11 (69%) of 16 showed changes consistent with ionizing radiation. Conclusion: Our findings support the hypothesis that ionizing radiation can cause transient positive results in the BTA test, but that these normalize with time. Although it requires further testing, it seems that the BTA test may be useful in the detection of recurrence in patients with bladder cancer who have been treated with

  9. Preliminary test Results for a 25K Sorption Cryocooler Designed for the UCSB Long Duration Balloon Cosmic Microwave Background Radiation Experiment

    Science.gov (United States)

    Wade, L. A.; Levy, A. R.

    1996-01-01

    A continuous operation, vibration-free, long-life 25K sorption cryocooler has been built and is now in final integration and performance testing. This cooler wil be flown on the University of California at Santa Barbara (UCSB) Long Duration Balloon (LDB) Cosmic Microwave Background Radiation Experiment.

  10. Assessment of the Radiation Enclosure Models in SPACE and RELAP5 with GOTA Test 27

    Energy Technology Data Exchange (ETDEWEB)

    Lee, T. B.; Lee, G. W.; Choi, T. S. [KEPCO, Daejeon (Korea, Republic of)

    2016-05-15

    SPACE (Safety and Performance Analysis Code) for nuclear power plant has been developed to calculate the transient thermal-hydraulic response of PWRs that can contain multiple types of fluids. Without explaining 3-D effects such as the change of fuel rod/guide tube thermal behavior as a result of the radiation heat transfer, the 1-D code could predict an unrealistically high peak clad temperature. A useful function to simulate the wall-to-wall radiation heat transfer is implemented in the SPACE and RELAP5 codes. This paper discusses the assessment results of the radiation enclosure model of SPACE and RELAP5. The capability of handling wall-to-wall radiation problem of the SPACE and the RELAP5 codes has been evaluated using the experimental data from the GOTA test facility. At the top of the bundle, the maximum errors of SPACE and RELAP5 are less than 1.6% and 2.3%, respectively. As noted, there is a small discrepancy between the calculated results and experimental data except for the predictions near the top of the test section. The SPACE code is based on the version 2.16 distributed by KHNP. In order to perform the simulation of the GOTA test 27, it was necessary to modify the SPACE code. There was the subroutine for an input process corresponding to the radiation model, the inp{sub c}heck function of the RadEncData Class, contained in a vulnerable algorithm to figure out the reciprocity rule of the view factor.

  11. Radiation tests on selected electrical insulating materials for high-power and high voltage application

    International Nuclear Information System (INIS)

    Liptak, G.; Schuler, R.; Haberthuer, B.; Mueller, H.; Zeier, W.; Maier, P.; Schoenbacher, H.

    1985-01-01

    This report presents a comprehensive set of test results on the irradiation of insulating materials and systems used for the windings of rotating machines, dry-type transformers, and magnet coils. The materials were: Novolac, bisphenol-A, and cycloaliphatic types of epoxy; saturated and unsaturated polyesterimide; silicone, phenolic, and acrylic resins. The reinforcement consisted of glass mat, glass roving, glass cloth, mica paper, polyester mat, polyester roving, polyester cloth, aromatic polyamide paper, or combinations thereof. The materials were irradiated in an 8 MW pool reactor up to integrated doses of 10 8 Gy. On most samples, flexural properties were examined as recommended by IEC Standard 544. For tapes and varnishes, the breakdown voltage was measured. The adhesion of copper bars glued together with an epoxy resin was examined by means of a lap-shear test. A cupping test by means of the Erichsen apparatus was used to measure the flexibility of varnishes. The results are presented in tables and graphs for each of the materials tested. Those from mechanical tests show that the radiation resistance of composite resin-rich insulations depends not only on the base resin combination and the reinforcement material but, to a large degree, also on the adhesion between the two. It appears that better adhesion, and consequently higher radiation resistance, is obtained by special surface treatments of glass fibres. For laminates, higher radiation resistance is obtained with glass mat and resin combinations than with glass cloth as reinforcing materials. The breakdown voltage tests show that the application of mechanical stress to most irradiated samples causes the insulation layer to crack, resulting in lower dielectric strength. For a number of materials, the critical properties of flexural strength and breakdown voltage are above 50% of the initial value at doses between 10 7 and 10 8 Gy, i.e. a radiation index of 7 to 8 at 10 5 Gy/h. (orig.)

  12. Risk Perception of Radiation Exposure of Villagers Living Near the Semipalatinsk Nuclear Test Site

    Science.gov (United States)

    Purvis-Roberts, K. L.

    2006-12-01

    Connecting scientific data to societal needs is particularly important with the complex environmental issues that face us in the near future, such as global warming and natural hazards. Once the scientific data is collected and analyzed, dissemination of the results needs to be communicated to the public in a way that can be easily understood without glossing over the complexity of the issue. An interesting case study derives from the primary nuclear test site for the former Soviet Union, located near the city of Semipalatinsk, Kazakhstan. Villagers living directly adjacent to the Semipalatinsk Nuclear Test Site (SNTS) were exposed continuously to radioactive clouds from atmospheric, above ground and underground nuclear tests. The people living in the region are still exposed to low levels of radiation through the environmental contamination of their food and water and have experienced a higher incidence of cancers and birth defects than people living in other regions of the country. A database of historical environmental data was collected throughout the nuclear testing period by the Soviet government, tracking radiation concentrations through food, water, and soil samples around the SNTS, but this environmental data was never shared with the villagers. In fact, only after the Soviet Union fell apart in 1989 did the people discover that they had been exposed to radiation during the past 40 years. Through preliminary interviews with villagers, physicians, and scientists who live near the SNTS, it was discovered that the three groups viewed the risk of radiation exposure very differently. By developing a risk perception survey to understand how the different groups perceived radiation risk, and then comparing the scientific data to the survey results, a better way to communicate the risk could be developed. The risk perception survey was given to over 800 people in East Kazakhstan Oblast, including villagers living near the SNTS, scientists who study the

  13. Radiation Testing, Characterization and Qualification Challenges for Modern Microelectronics and Photonics Devices and Technologies

    Science.gov (United States)

    LaBel, Kenneth A.; Cohn, Lewis M.

    2008-01-01

    At GOMAC 2007, we discussed a selection of the challenges for radiation testing of modern semiconductor devices focusing on state-of-the-art memory technologies. This included FLASH non-volatile memories (NVMs) and synchronous dynamic random access memories (SDRAMs). In this presentation, we extend this discussion in device packaging and complexity as well as single event upset (SEU) mechanisms using several technology areas as examples including: system-on-a-chip (SOC) devices and photonic or fiber optic systems. The underlying goal is intended to provoke thought for understanding the limitations and interpretation of radiation testing results.

  14. The use of bacteriological preparates to test processes in radiation sterilization

    International Nuclear Information System (INIS)

    Gazso, L.; Igali, S.; Kovacs, A.

    1976-01-01

    Environmental factors influencing the irradiation sensitivity of micro-organisms, bacterium stocks being suitable for biological checking up and spore test organism used nowadays are reviewed. According to the tests made on Bacillus pumilus E601 and Bacillus sphaericus Csub(I)A stockes with Noratom, PX-γ-30 and 60 Co radiation sources the irradiation sensitivity of the same products irradiated with the same dose can differ in the function of the radiation source and the dose rate. It seems necessary to produce the test preparates in the same way in a central laboratory and to calibrate them to single radiation sources. It is advisable to check up the factual microbicidal effect of the nominal dosage by a biological dosimeter. The method reviewed potentiates a much higher confidence than that of conventional sterility tests and its additional advantage is the cheapness. (K.A.)

  15. Laser system for testing radiation imaging detector circuits

    Science.gov (United States)

    Zubrzycka, Weronika; Kasinski, Krzysztof

    2015-09-01

    Performance and functionality of radiation imaging detector circuits in charge and position measurement systems need to meet tight requirements. It is therefore necessary to thoroughly test sensors as well as read-out electronics. The major disadvantages of using radioactive sources or particle beams for testing are high financial expenses and limited accessibility. As an alternative short pulses of well-focused laser beam are often used for preliminary tests. There are number of laser-based devices available on the market, but very often their applicability in this field is limited. This paper describes concept, design and validation of laser system for testing silicon sensor based radiation imaging detector circuits. The emphasis is put on keeping overall costs low while achieving all required goals: mobility, flexible parameters, remote control and possibility of carrying out automated tests. The main part of the developed device is an optical pick-up unit (OPU) used in optical disc drives. The hardware includes FPGA-controlled circuits for laser positioning in 2 dimensions (horizontal and vertical), precision timing (frequency and number) and amplitude (diode current) of short ns-scale (3.2 ns) light pulses. The system is controlled via USB interface by a dedicated LabVIEW-based application enabling full manual or semi-automated test procedures.

  16. The manufacture of system for testing static random access memory radiation effect

    International Nuclear Information System (INIS)

    Chen Rui; Yang Chen

    2008-01-01

    Space radiation effects will lead to single event upset, event latch up and other phenomena in SRAM devices. This paper introduces the hardware, software composition and related testing technology of SRAM radiation effect testing device. Through to the SRAM chip current detection and power protection, it has solved the SRAM chip damage question in the SRAM experiment. It has accessed to the expected experimental data by using the device in different source of radiation conducted on SRAM Experimental study of radiation effects. It provides important references in the assessment of operational life and reinforcement of the memory carried in the satellites. (authors)

  17. Offsite environmental monitoring report: Radiation monitoring around United States nuclear test areas, calendar year 1991

    International Nuclear Information System (INIS)

    Chaloud, D.J.; Dicey, B.B.; Mullen, A.A.; Neale, A.C.; Sparks, A.R.; Fontana, C.A.; Carroll, L.D.; Phillips, W.G.; Smith, D.D.; Thome, D.J.

    1992-01-01

    This report describes the Offsite Radiation Safety Program conducted during 1991 by the Environmental Protection Agency's (EPA's) Environmental Monitoring Systems Laboratory-Las Vegas. This laboratory operates an environmental radiation monitoring program in the region surrounding the Nevada Test Site (NTS) and at former test sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The surveillance program is designed to measure levels and trends of radioactivity, if present, in the environment surrounding testing areas to ascertain whether current radiation levels and associated doses to the general public are in compliance with existing radiation protection standards. The surveillance program additionally has the responsibility to take action to protect the health and well being of the public in the event of any accidental release of radioactive contaminants. Offsite levels of radiation and radioactivity are assessed by sampling milk, water, and air; by deploying thermoluminescent dosimeters (TLDs) and using pressurized ion chambers (PICs); and by biological monitoring of animals, food crops, and humans. Personnel with mobile monitoring equipment are placed in areas downwind from the test site prior to each nuclear weapons test to implement protective actions, provide immediate radiation monitoring, and obtain environmental samples rapidly after any occurrence of radioactivity release. Comparison of the measurements and sample analysis results with background levels and with appropriate standards and regulations indicated that there was no radioactivity detected offsite by the various EPA monitoring networks and no exposure above natural background to the population living in the vicinity of the NTS that could be attributed to current NTS activities. Annual and long-term trends were evaluated in the Noble Gas, Tritium, Milk Surveillance, Biomonitoring, TLD, PIC networks, and the Long-Term Hydrological Monitoring Program

  18. Chalcogenide Glass Radiation Sensor; Materials Development, Design and Device Testing

    Energy Technology Data Exchange (ETDEWEB)

    Mitkova, Maria; Butt, Darryl; Kozicki, Michael; Barnaby, Hugo

    2013-04-30

    studied the effect of x-rays and γ-rays, on thin film chalcogenide glasses and applied them in conjunction with film incorporating a silver source in a new type of radiation sensor for which we have an US patent application [3]. In this report, we give data about our studies regarding our designed radiation sensor along with the testing and performance at various radiation doses. These studies have been preceded by materials characterization research related to the compositional and structural characteristics of the active materials used in the radiation sensor design. During the work on the project, we collected a large volume of material since every experiment was repeated many times to verify the results. We conducted a comprehensive material research, analysis and discussion with the aim to understand the nature of the occurring effects, design different structures to harness these effects, generated models to aid in the understanding the effects, built different device structures and collected data to quantify device performance. These various aspects of our investigation have been detailed in previous quarterly reports. In this report, we present our main results and emphasize on the results pertaining to the core project goals materials development, sensor design and testing and with an emphasis on classifying the appropriate material and design for the optimal application. The report has three main parts: (i) Presentation of the main data; (ii) Bulleted summary of the most important results; (iii) List of the patent, journal publications, conference proceedings and conferences participation, occurring as a result of working on the project.

  19. Experimental test of liquid droplet radiator performance

    International Nuclear Information System (INIS)

    Mattick, A.T.; Simon, M.A.

    1986-01-01

    This liquid droplet radiator (LDR) is evolving rapidly as a lightweight system for heat rejection in space power systems. By using recirculating free streams of submillimeter droplets to radiate waste energy directly to space, the LDR can potentially be an order of magnitude lighter than conventional radiator systems which radiate from solid surfaces. The LDR is also less vulnerable to micrometeoroid damage than are conventional radiators, and it has a low transport volume. Three major development issues of this new heat rejection system are the ability to direct the droplet streams with sufficient precision to avoid fluid loss, radiative performance of the array of droplet streams which comprise the radiating elements of the LDR, and the efficacy of the droplet stream collector, again with respect to fluid loss. This paper reports experimental results bearing on the first two issues - droplet aiming in a multikilowatt-sized system, and radiated power from a large droplet array. Parallel efforts on droplet collection and LDR system design are being pursued by several research groups

  20. Procedure to carry out leakage test in beta radiation sealed sources emitters of 90Sr/90Y

    International Nuclear Information System (INIS)

    Alvarez R, J. T.

    2010-09-01

    In the alpha-beta room of the Secondary Laboratory of Dosimetric Calibration of the Metrology Department of Ionizing Radiations ophthalmic applicators are calibrated in absorbed dose terms in water D w ; these applicators, basically are emitter sealed sources of pure beta radiation of 90 Sr / 90 Y. Concretely, the laboratory quality system indicates to use the established procedure for the calibration of these sources, which establishes the requirement of to carry out a leakage test, before to calibrate the source. However, in the Laboratory leakage test certificates sent by specialized companies in radiological protection services have been received, in which are used gamma spectrometry equipment s for beta radiation leakage tests, since it is not reliable to detect pure beta radiation with a scintillating detector with NaI crystal, (because it could detect the braking radiation produced in the detector). Therefore the Laboratory has had to verify the results of the tests with a correct technique, with the purpose of determining the presence of sources with their altered integrity and radioactive material leakage. The objective of this work is to describe a technique for beta activity measurement - of the standard ISO 7503, part 1 (1988) - and its application with a detector Gm plane (type pankage) in the realization of leakage tests in emitter sources of pure beta radiation, inside the mark of quality assurance indicated by the report ICRU 76. (Author)

  1. Design and testing of an innovative solar radiation measurement device

    International Nuclear Information System (INIS)

    Badran, Omar; Al-Salaymeh, Ahmed; El-Tous, Yousif; Abdala, Wasfi

    2010-01-01

    After review of studies conducted on the solar radiation measuring systems, a new innovative instrument that would help in measuring the accurate solar radiation on horizontal surfaces has been designed and tested. An advanced instrument with ease of use and high precision that would enable the user to take the readings in terms of solar intensity (W/m 2 ) has been tested. Also, the innovative instrument can record instantaneous readings of the solar intensities as well as the averages value of the solar radiation flux during certain periods of time. The instrument based in its design on being programmed by programmable interfacing controller (PIC). Furthermore, the power supply circuit is fed by the solar energy cells and does not need an external power source.

  2. The Semipalatinsk nuclear test site: a first assessment of the radiological situation and the test-related radiation doses in the surrounding territories.

    Science.gov (United States)

    Gusev, B I; Abylkassimova, Z N; Apsalikov, K N

    1997-09-01

    As a result of atmospheric nuclear tests at the Semipalatinsk test site 'Polygon', adjacent territories were contaminated by radionuclide fallout. The population of some districts in the Semipalatinsk oblast were exposed to elevated levels of radiation. Contamination and exposure mostly resulted from early atmospheric tests. The radiological situation of the Semipalatinsk oblast is described. Effective dose estimates due to external and internal exposure attributable to the 1949 and 1953 tests in villages near the Polygon range from 70 mSv to 4470 mSv.

  3. Radiation Tolerance Qualification Tests of the Final Source Interface Unit for the ALICE Experiment

    CERN Document Server

    Dénes, E; Futó, E; Kerék, A; Kiss, T; Molnár, J; Novák, D; Soós, C; Tölyhi, T; Van de Vyvre, P

    2007-01-01

    The ALICE Detector Data Link (DDL) is a high-speed optical link designed to interface the readout electronics of ALICE sub-detectors to the DAQ computers. The Source Interface Unit (SIU) of the DDL will operate in radiation environment. Previous tests showed that a configuration loss of SRAM-based FPGA devices may happen and the frequency of undetected data errors in the FPGA user memory area is also not acceptable. Therefore, we redesigned the SIU card using another FPGA based on flash technology. In order to detect bit errors in the user memory we added parity check logic to the design. The new SIU has been extensively tested using neutron and proton irradiation to verify its radiation tolerance. In this paper we summarize the design changes, introduce the final design, and the results of the radiation tolerance measurements on the final card.

  4. Test equipment used for radiation protection type testing of aerosol filters at the National Board of Nuclear Safety and Radiation Protection (SAAS)

    International Nuclear Information System (INIS)

    Ullmann, W.; Przyborowski, S.

    1977-01-01

    Following a description of the overall design of test equipment developed in the SAAS for radiation protection type testing of aerosol filters, the most important physical and technical details concerning the preparation and measurement of test aerosols as well as the sampling procedure upstream and downstream of the filter to the tested, are comprehensively discussed. Furthermore, experiences gained during several years with different devices for mixing and diluting the aerosols are reported. (author)

  5. Solar radiation inside greenhouses covered with semitransparent photovoltaic film: first experimental results

    Directory of Open Access Journals (Sweden)

    Alvaro Marucci

    2013-09-01

    Full Text Available The southern Italian regions are characterized by climatic conditions with high values of solar radiation and air temperature. This has allowed the spread of protected structures both as a defense against critical winter conditions both for growing off-season. The major energy source for these greenhouses is given by solar energy and artificial energy is used rarely. So the problem in the use of greenhouses in these areas, if anything, is opposite to that of the northern areas. In these places you must try to mitigate often the solar radiation inside the greenhouses with suitable measures or abandon for a few months the cultivation inside these structures. The solar radiation intercepted by passive means can be used for other purposes through the uptake and transformation by the photovoltaic panels whose use however is problematic due to complete opacity of the cells. New photosensitive materials partially transparent to solar radiation onto flexible media, allow to glimpse the possibility of using them to greenhouses cover, getting the dual effect of partially screen the greenhouse and use the surplus to generate electricity. The research was carried out to evaluate the possibility of using a flexible photovoltaic film realized by the University of Rome Tor Vergata (research group of ECOFLECS project coordinated by prof. Andrea Reale for covering greenhouses. Two greenhouses in small scale were built: one covered with photovoltaic film and one covered with EVA film for test. In both greenhouses during the first research period it was grown a variety of dwarf tomato. The research was carried out comparing the solar radiation that enters into greenhouse in the summer (August 2012 and in winter conditions (December 2012 in both greenhouses. The result show that the average ratio between the daily global solar radiation under the photovoltaic film and outside radiation is about 37%, while between the radiation under EVA film and outside radiation

  6. Preliminary analysis of accelerated space flight ionizing radiation testing

    Science.gov (United States)

    Wilson, J. W.; Stock, L. V.; Carter, D. J.; Chang, C. K.

    1982-01-01

    A preliminary analysis shows that radiation dose equivalent to 30 years in the geosynchronous environment can be accumulated in a typical composite material exposed to space for 2 years or less onboard a spacecraft orbiting from perigee of 300 km out to the peak of the inner electron belt (approximately 2750 km). Future work to determine spacecraft orbits better tailored to materials accelerated testing is indicated. It is predicted that a range of 10 to the 9th power to 10 to the 10th power rads would be accumulated in 3-6 mil thick epoxy/graphite exposed by a test spacecraft orbiting in the inner electron belt. This dose is equivalent to the accumulated dose that this material would be expected to have after 30 years in a geosynchronous orbit. It is anticipated that material specimens would be brought back to Earth after 2 years in the radiation environment so that space radiation effects on materials could be analyzed by laboratory methods.

  7. Standardization of penetrating radiation testing system

    International Nuclear Information System (INIS)

    Wiley, P.A.; Aronson, H.L.

    1979-01-01

    Standardization is provided to control system gain of a penetrating radiation testing system by periodically inspecting a reference object in the same manner as the product samples so as to generate a stabilization signal which is compared to a reference signal. The difference, if any, between the stabilization signal and the reference signal is integrated and the integrated signal is used to correct the gain of the system

  8. Comparison of proton microbeam and gamma irradiation for the radiation hardness testing of silicon PIN diodes

    Science.gov (United States)

    Jakšić, M.; Grilj, V.; Skukan, N.; Majer, M.; Jung, H. K.; Kim, J. Y.; Lee, N. H.

    2013-09-01

    Simple and cost-effective solutions using Si PIN diodes as detectors are presently utilized in various radiation-related applications in which excessive exposure to radiation degrades their charge transport properties. One of the conventional methods for the radiation hardness testing of such devices is time-consuming irradiation with electron beam or gamma-ray irradiation facilities, high-energy proton accelerators, or with neutrons from research reactors. Recently, for the purpose of radiation hardness testing, a much faster nuclear microprobe based approach utilizing proton irradiation has been developed. To compare the two different irradiation techniques, silicon PIN diodes have been irradiated with a Co-60 gamma radiation source and with a 6 MeV proton microbeam. The signal degradation in the silicon PIN diodes for both irradiation conditions has been probed by the IBIC (ion beam induced charge) technique, which can precisely monitor changes in charge collection efficiency. The results presented are reviewed on the basis of displacement damage calculations and NIEL (non-ionizing energy loss) concept.

  9. Offsite environmental monitoring report: Radiation monitoring around United States nuclear test areas, calendar year 1991

    Energy Technology Data Exchange (ETDEWEB)

    Chaloud, D.J.; Dicey, B.B.; Mullen, A.A.; Neale, A.C.; Sparks, A.R.; Fontana, C.A.; Carroll, L.D.; Phillips, W.G.; Smith, D.D.; Thome, D.J.

    1992-01-01

    This report describes the Offsite Radiation Safety Program conducted during 1991 by the Environmental Protection Agency`s (EPA`s) Environmental Monitoring Systems Laboratory-Las Vegas. This laboratory operates an environmental radiation monitoring program in the region surrounding the Nevada Test Site (NTS) and at former test sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The surveillance program is designed to measure levels and trends of radioactivity, if present, in the environment surrounding testing areas to ascertain whether current radiation levels and associated doses to the general public are in compliance with existing radiation protection standards. The surveillance program additionally has the responsibility to take action to protect the health and well being of the public in the event of any accidental release of radioactive contaminants. Offsite levels of radiation and radioactivity are assessed by sampling milk, water, and air; by deploying thermoluminescent dosimeters (TLDs) and using pressurized ion chambers (PICs); and by biological monitoring of animals, food crops, and humans. Personnel with mobile monitoring equipment are placed in areas downwind from the test site prior to each nuclear weapons test to implement protective actions, provide immediate radiation monitoring, and obtain environmental samples rapidly after any occurrence of radioactivity release. Comparison of the measurements and sample analysis results with background levels and with appropriate standards and regulations indicated that there was no radioactivity detected offsite by the various EPA monitoring networks and no exposure above natural background to the population living in the vicinity of the NTS that could be attributed to current NTS activities. Annual and long-term trends were evaluated in the Noble Gas, Tritium, Milk Surveillance, Biomonitoring, TLD, PIC networks, and the Long-Term Hydrological Monitoring Program.

  10. Radiation hardness tests of SiPMs for the JLab Hall D Barrel calorimeter

    International Nuclear Information System (INIS)

    Qiang, Yi; Zorn, Carl; Barbosa, Fernando; Smith, Elton

    2013-01-01

    We report on the measurement of the neutron radiation hardness of silicon photomultipliers (SiPMs) manufactured by Hamamatsu Corporation in Japan and SensL in Ireland. Samples from both companies were irradiated by neutrons created by a 1 GeV electron beam hitting a thin lead target at Jefferson Lab Hall A. More tests regarding the temperature dependence of the neutron radiation damage and self-annealing were performed on Hamamatsu SiPMs using a calibrated Am–Be neutron source from the Jefferson Lab Radiation Control group. As the result of irradiation both dark current and dark rate increase linearly as a function of the 1 MeV equivalent neutron fluence and a temperature dependent self-annealing effect is observed.

  11. Design and radiation tests on a LED based emergency evacuation directional lighting

    CERN Document Server

    Trikoupis, Nikolaos

    2017-01-01

    A LED (Light Emitting Diode) based directional lighting system has been designed to indicate the best evacuation direction for applications like the Large Hadron Collider (LHC) tunnel. The design includes constraints for redundancy required by safety systems and for components selection by radiation effects. Most of the literature for radiation effects on LEDs concern digital communications systems, although some recent reports do exist for visible spectrum power LEDs and the reduction in light output versus dose is coherent with the results presented in this paper. Prototype lighting units were irradiated in CERN’s CHARM facility up to a Total Integrated Dose (TID) of 870 Gy and no failures were observed. This paper describes the basic design, presents field tests and the effects of radiation on the LEDs luminance.

  12. Test results of the UNK superconducting dipole magnets

    International Nuclear Information System (INIS)

    Ageev, A.I.; Andreev, N.I.; Gridasov, V.I.

    1993-01-01

    Results of studied, training, temperature and velocity dependence of 25 critical current of superconducting magnets (SC), as well as, of dynamic losses of dipole and statical inflows in UNK operating cycle at currents that are higher than critical ones (5250 A), are presented. Service life tests of SC-dipole demonstrated that their design may ensure durable operation of magnets under UNK conditions. Conclusions are made that temperature margin of magnets equal to 0.8 K will enable to ensure their reliable operation under dynamic and radiation heat releases at acceleration and extraction of beam, as well as, under emergency extraction of stored energy. 4 refs.; 5 figs

  13. Test tools of physics radiography children as a support for safety radiation and safety patients

    International Nuclear Information System (INIS)

    Siti Masrochah; Yeti Kartikasari; Ardi Soesilo Wibowo

    2013-01-01

    Radiographic examination of the thorax children aged 1-3 years have a high sufficiently failure. This failure is caused by the movement and difficulty positioning the patient, resulting in the risk of repeat radiographs to patient safety particularly unnecessary radiation risks. It is therefore necessary to develop research on children design fixation devices. This research aims to create a design tool fixation on radiographs children to support radiation safety and patient safety. This research is a descriptive exploratory approach to tool design. The independent variables were the design tools, variable tool function test results, and radiographic variables controlled thorax. The procedure is done by designing data collection tools, further trials with 20 samples. Processing and analysis of data is done by calculating the performance assessment tool scores with range 1-3. The results showed that the design tool of fixation in the form of standard radiographic cassette equipped with chairs and some form of seat belt fixation. The procedure uses a tool fixation is routine radiographic follow thorax child in an upright position. Function test results aids fixation is to have an average score of 2.66, which means good. While the test results for each component, the majority of respondents stated that the reliability of the device is quite good with a score of 2.45 (60 %), convenience tool with a score of 2.60 (70 %), quality of the radiographs did not incontinence of the thorax radiograph with a score 2.55 (85 %), the child protection (security) with a score of 2.70 (70 %), good design aesthetic design with a score of 2.80 (80 %), addition of radiation from the others on the use of these tools do not need with a score of 2.80 (80 %), and there is no additional radiation due to repetitions with a score of 2.85 (90 %). (author)

  14. IVVS actuating system compatibility test to ITER gamma radiation conditions

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, Paolo, E-mail: paolo.rossi@enea.it [Associazione EURATOM-ENEA sulla Fusione, 45 Via Enrico Fermi, 00044 Frascati, Rome (Italy); Collibus, M. Ferri de; Florean, M.; Monti, C.; Mugnaini, G.; Neri, C.; Pillon, M.; Pollastrone, F. [Associazione EURATOM-ENEA sulla Fusione, 45 Via Enrico Fermi, 00044 Frascati, Rome (Italy); Baccaro, S.; Piegari, A. [ENEA CR Casaccia, 301 Via Anguillarese, 00123 Santa Maria di Galeria, Rome (Italy); Damiani, C.; Dubus, G. [Fusion For Energy c/Josep Pla, n° 2 Torres Diagonal Litoral, 08019 Barcelona (Spain)

    2013-10-15

    Highlights: • ENEA developed and tested a prototype of a laser In Vessel Viewing and ranging System (IVVS) for ITER. • One piezo-motor prototype has been tested on the ENEA Calliope gamma irradiation facility to verify its compatibility to ITER gamma radiation conditions. • After a total dose of more than 4 MGy the piezo-motor maintained almost the same working parameters monitored before test without any evident and significant degradation of functionality. • After the full gamma irradiation test, the same piezo-motor assembly will be tested with 14 MeV neutrons irradiation using ENEA FNG facility. -- Abstract: The In Vessel Viewing System (IVVS) is a fundamental remote handling equipment, which will be used to make a survey of the status of the blanket first wall and divertor plasma facing components. A design and testing activity is ongoing, in the framework of a Fusion for Energy (F4E) grant agreement, to make the IVVS probe design compatible with ITER operating conditions and in particular, but not only, with attention to neutrons and gammas fluxes and both space constraints and interfaces. The paper describes the testing activity performed on the customized piezoelectric motors and the main components of the actuating system of the IVVS probe with reference to ITER gamma radiation conditions. In particular the test is performed on the piezoelectric motor, optical encoder and small scale optical samples .The test is carried out on the ENEA Calliope gamma irradiation facility at ITER relevant gamma fields at rate of about 2.5 kGy/h and doses of 4 MGy. The paper reports in detail the setup arrangement of the test campaign in order to verify significant working capability of the IVVS actuating components and the results are shown in terms of functional performances and parameters. The overall test campaign on IVVS actuating system will be completed on other ENEA testing facilities in order to verify compatibility to Magnetic field, neutrons and thermal

  15. IVVS actuating system compatibility test to ITER gamma radiation conditions

    International Nuclear Information System (INIS)

    Rossi, Paolo; Collibus, M. Ferri de; Florean, M.; Monti, C.; Mugnaini, G.; Neri, C.; Pillon, M.; Pollastrone, F.; Baccaro, S.; Piegari, A.; Damiani, C.; Dubus, G.

    2013-01-01

    Highlights: • ENEA developed and tested a prototype of a laser In Vessel Viewing and ranging System (IVVS) for ITER. • One piezo-motor prototype has been tested on the ENEA Calliope gamma irradiation facility to verify its compatibility to ITER gamma radiation conditions. • After a total dose of more than 4 MGy the piezo-motor maintained almost the same working parameters monitored before test without any evident and significant degradation of functionality. • After the full gamma irradiation test, the same piezo-motor assembly will be tested with 14 MeV neutrons irradiation using ENEA FNG facility. -- Abstract: The In Vessel Viewing System (IVVS) is a fundamental remote handling equipment, which will be used to make a survey of the status of the blanket first wall and divertor plasma facing components. A design and testing activity is ongoing, in the framework of a Fusion for Energy (F4E) grant agreement, to make the IVVS probe design compatible with ITER operating conditions and in particular, but not only, with attention to neutrons and gammas fluxes and both space constraints and interfaces. The paper describes the testing activity performed on the customized piezoelectric motors and the main components of the actuating system of the IVVS probe with reference to ITER gamma radiation conditions. In particular the test is performed on the piezoelectric motor, optical encoder and small scale optical samples .The test is carried out on the ENEA Calliope gamma irradiation facility at ITER relevant gamma fields at rate of about 2.5 kGy/h and doses of 4 MGy. The paper reports in detail the setup arrangement of the test campaign in order to verify significant working capability of the IVVS actuating components and the results are shown in terms of functional performances and parameters. The overall test campaign on IVVS actuating system will be completed on other ENEA testing facilities in order to verify compatibility to Magnetic field, neutrons and thermal

  16. SU-F-T-249: Application of Human Factors Methods: Usability Testing in the Radiation Oncology Environment

    International Nuclear Information System (INIS)

    Warkentin, H; Bubric, K; Giovannetti, H; Graham, G; Clay, C

    2016-01-01

    Purpose: As a quality improvement measure, we undertook this work to incorporate usability testing into the implementation procedures for new electronic documents and forms used by four affiliated radiation therapy centers. Methods: A human factors specialist provided training in usability testing for a team of medical physicists, radiation therapists, and radiation oncologists from four radiotherapy centers. A usability testing plan was then developed that included controlled scenarios and standardized forms for qualitative and quantitative feedback from participants, including patients. Usability tests were performed by end users using the same hardware and viewing conditions that are found in the clinical environment. A pilot test of a form used during radiotherapy CT simulation was performed in a single department; feedback informed adaptive improvements to the electronic form, hardware requirements, resource accessibility and the usability testing plan. Following refinements to the testing plan, usability testing was performed at three affiliated cancer centers with different vault layouts and hardware. Results: Feedback from the testing resulted in the detection of 6 critical errors (omissions and inability to complete task without assistance), 6 non-critical errors (recoverable), and multiple suggestions for improvement. Usability problems with room layout were detected at one center and problems with hardware were detected at one center. Upon amalgamation and summary of the results, three key recommendations were presented to the document’s authors for incorporation into the electronic form. Documented inefficiencies and patient safety concerns related to the room layout and hardware were presented to administration along with a request for funding to purchase upgraded hardware and accessories to allow a more efficient workflow within the simulator vault. Conclusion: By including usability testing as part of the process when introducing any new document

  17. SU-F-T-249: Application of Human Factors Methods: Usability Testing in the Radiation Oncology Environment

    Energy Technology Data Exchange (ETDEWEB)

    Warkentin, H [Cross Cancer Institute, Edmonton, AB (Canada); Bubric, K [Alberta Health Services, Calgary, AB (Canada); Giovannetti, H [Jack Ady Cancer Centre, Lethbridge, AB (Canada); Graham, G [Tom Baker Cancer Centre, Calgary, AB (Canada); Clay, C [Central Alberta Cancer Centre, Red Deer, AB (Canada)

    2016-06-15

    Purpose: As a quality improvement measure, we undertook this work to incorporate usability testing into the implementation procedures for new electronic documents and forms used by four affiliated radiation therapy centers. Methods: A human factors specialist provided training in usability testing for a team of medical physicists, radiation therapists, and radiation oncologists from four radiotherapy centers. A usability testing plan was then developed that included controlled scenarios and standardized forms for qualitative and quantitative feedback from participants, including patients. Usability tests were performed by end users using the same hardware and viewing conditions that are found in the clinical environment. A pilot test of a form used during radiotherapy CT simulation was performed in a single department; feedback informed adaptive improvements to the electronic form, hardware requirements, resource accessibility and the usability testing plan. Following refinements to the testing plan, usability testing was performed at three affiliated cancer centers with different vault layouts and hardware. Results: Feedback from the testing resulted in the detection of 6 critical errors (omissions and inability to complete task without assistance), 6 non-critical errors (recoverable), and multiple suggestions for improvement. Usability problems with room layout were detected at one center and problems with hardware were detected at one center. Upon amalgamation and summary of the results, three key recommendations were presented to the document’s authors for incorporation into the electronic form. Documented inefficiencies and patient safety concerns related to the room layout and hardware were presented to administration along with a request for funding to purchase upgraded hardware and accessories to allow a more efficient workflow within the simulator vault. Conclusion: By including usability testing as part of the process when introducing any new document

  18. COMMISSIONING AND FIRST RESULTS FROM CHANNELING RADIATION AT FAST

    Energy Technology Data Exchange (ETDEWEB)

    Halavanau, A. [NIU, DeKalb; Mihalcea, D. [NIU, DeKalb; Broemmelsiek, D. [Fermilab; Edstrom, D. [Fermilab; Sen, T. [Fermilab; Romanov, A. [Fermilab; Ruan, J. [Fermilab; Shiltsev, V. [Fermilab; Kobak, P. [BYU-I; Rush, W. [Kansas U.; Hyun, J. [Tsukuba, Graduate U. Adv. Studies

    2016-10-18

    X-rays have widespread applications in science and industry, but developing a simple, compact, and high-quality X-ray source remains a challenge. Our collaboration has explored the possible use of channeling radiation driven by a 50 MeV low-emittance electron beam to produce narrowband hard X-rays with photon energy of 40 to 140 keV [8,9,11]. Here we present the simulated X-ray spectra including the background bremsstrahlung contribution, and a description of the required optimization of the relevant electron-beam parameters necessary to maximize brilliance of the resulting X-ray beam. Results are presented from our test of this, carried out at the Fermilab Accelerator Science & Technology (FAST) facility’s 50-MeV low-energy electron injector. As a result of the beam parameters, made possible by the photo-injector based SRF linac, the average brilliance at FAST was expected to be about one order of magnitude higher than that in previous experiments.

  19. Implementation and testing of a multivariate inverse radiation transport solver

    International Nuclear Information System (INIS)

    Mattingly, John; Mitchell, Dean J.

    2012-01-01

    Detection, identification, and characterization of special nuclear materials (SNM) all face the same basic challenge: to varying degrees, each must infer the presence, composition, and configuration of the SNM by analyzing a set of measured radiation signatures. Solutions to this problem implement inverse radiation transport methods. Given a set of measured radiation signatures, inverse radiation transport estimates properties of the source terms and transport media that are consistent with those signatures. This paper describes one implementation of a multivariate inverse radiation transport solver. The solver simultaneously analyzes gamma spectrometry and neutron multiplicity measurements to fit a one-dimensional radiation transport model with variable layer thicknesses using nonlinear regression. The solver's essential components are described, and its performance is illustrated by application to benchmark experiments conducted with plutonium metal. - Highlights: ► Inverse problems, specifically applied to identifying and characterizing radiation sources . ► Radiation transport. ► Analysis of gamma spectroscopy and neutron multiplicity counting measurements. ► Experimental testing of the inverse solver against measurements of plutonium.

  20. [Regulatory radiation risks' for the population and natural objects within the Semipalatinsk Test Site].

    Science.gov (United States)

    Spiridonov, S I; Teten'kin, V L; Mukusheva, M K; Solomatin, V M

    2008-01-01

    Advisability of using risks as indicators for estimating radiation impacts on environmental objects and humans has been jusified. Results are presented from identification of dose burdens distribution to various cohorts of the population living within the Semipalatinsk Test Site (STS) and consuming contaminated farm products. Parameters of dose burden distributions are estimated for areas of livestock grazing and the most contaminated sectors within these areas. Dose distributions to meadow plants for the above areas have been found. Regulatory radiation risks for the STS population and meadow ecosystem components have been calculated. Based on the parameters estimated, levels of radiation exposure of the population and herbaceous plants have been compared.

  1. Irradiation tests of a small-sized motor with radiation resistance

    International Nuclear Information System (INIS)

    Nakamichi, M.; Ishitsuka, E.; Shimakawa, S.; Kan, S.

    2007-01-01

    In the Test Blanket Module (TBM) of the International Thermonuclear Experimental Reactor (ITER), tritium production and release behavior will be studied using neutrons from fusion reactions, as the blanket development for a demonstration (DEMO) reactor. For development of the TBM, in-pile functional tests are planned, including an integrated irradiation experiment of a fusion blanket mock-up for pulsed operation simulating the ITER operation mode, using the Japan Materials Testing Reactor (JMTR) of Japan Atomic Energy Agency (JAEA).Due to be installed in an irradiation rig, a small-sized motor has to be developed for rotating a neutron absorber with a window to realize the simulated pulse operation. Since degradation of materials of the motor may be caused by radiation damage due to neutron and gamma-ray irradiation, it is important to examine the soundness of the motor materials under the neutron and gamma irradiation.In the present study, a small-sized motor with increased radiation resistance was developed as follows. A design of a commercial alternate current (AC) servomotor was adopted in the base structure, and some components of the motor were replaced by those made of radiation-proof materials, through elimination of organic materials. Polyester-coated wire for field coil and epoxy for fixed resin were replaced by polyimide-coated wire and polysiloxane filled with MgO and Al 2 O 3 , respectively. Furthermore, inorganic lubricant (Mo-based coating of 4 micro meter in thickness) was treated on the surface of a gear, instead of organic (polyphenylether) oil.Radiation-induced degradation of the components of the developed small-sized motor was examined using JMTR and the Japan Research Reactor No.4 (JRR-4) of JAEA. The motor was operating normally up to a gamma-ray dose of 7 x 10 8 Gy, a fast neutron (E>1 MeV) fluence of 2 x 10 21 m -2 and a thermal neutron (E 22 m -2 . The irradiated gamma-ray dose for this motor is about 700 times as high as the operation

  2. Beam and radiation tests of a fast, warm liquid open-quotes swimming poolclose quotes calorimeter

    International Nuclear Information System (INIS)

    Kadyk, J.

    1993-09-01

    A fast, warm liquid calorimeter module with lead absorber immersed in tetramethyl pentane (TMP) as the liquid medium (i.e. a open-quotes swimming poolclose quotes configuration) has been built and tested in a high energy beam at FNAL, and exposed to intense radiation from a strong Co 60 source. A two-tower prototype, incorporating the concept of the electrostatic transformer for fast readout, exhibited very good uniformity and small cross-talk in the beam test. This same calorimeter was exposed to over 10 Mrad of radiation from the Co 60 source, and the electron drift lifetime was measured as a function of accumulated dose. The lifetime improved significantly with small doses of radiation, up to a few hundred krad, then decreased gradually at higher doses, and extrapolated to a minimum useful lifetime of 0.1 μs at over 150 Mrad. This result was confirmed by measurements on a small single-electrode test cell which was irradiated to more than 25 Mrad. In this case, the lifetime decreased from 10μs to 0.1 μs when extrapolated to a dose of over 600 Mrad. This cell was also used to measure the effect of positive ion open-quotes space chargeclose quotes buildup under intense radiation. The results suggest that such effects are small even at the highest intensity available, about 1.3 Mrad/day, for applied fields ≥25 kV/cm

  3. Tests of a photovoltaic pump: first results

    International Nuclear Information System (INIS)

    Petroselli, A.; Pica, M.; Biondi, P.

    2005-01-01

    The paper deals with a first series of tests conducted in Viterbo (42 deg 25 min North, 12 deg 06 min East) on a PV-DC pump. This series lasted eight months - from the first days of January to the end of August 2003 - and involved measurements of: air and PV-module temperatures; solar radiations, both on horizontal surface and tilted module surface; voltage and intensity of the DC currents from the panel; pump pressures and flow rates. In total, as much as 3,150 data were collected every day. The analysis of the data allowed to obtain some simple empirical relations expressing daily pumped water volumes, instantaneous flow rates and system efficiencies as a function of both radiations and total dynamic heads [it

  4. An experimental test of the linear no-threshold theory of radiation carcinogenesis

    International Nuclear Information System (INIS)

    Cohen, B.L.

    1990-01-01

    There is a substantial body of quantitative information on radiation-induced cancer at high dose, but there are no data at low dose. The usual method for estimating effects of low-level radiation is to assume a linear no-threshold dependence. if this linear no-threshold assumption were not used, essentially all fears about radiation would disappear. Since these fears are costing tens of billions of dollars, it is most important that the linear no-threshold theory be tested at low dose. An opportunity for possibly testing the linear no-threshold concept is now available at low dose due to radon in homes. The purpose of this paper is to attempt to use this data to test the linear no-threshold theory

  5. Technical critique on radiation test facilities for the CTR surface and materials program

    International Nuclear Information System (INIS)

    Persiani, P.J.

    1975-02-01

    Major radiation test facilities will be necessary in the near-term (5 years) and long-term (greater than 10 years) future for the timely development and understanding of fusion confinement systems and of prototype fusion power reactors. The study includes the technical justifications and requirements for CTR Neutron and Plasma Radiation Test Facilities. The initial technical critique covers the feasibility and design problems: in upgrading the performance of the accelerator-rotating (solid TiT) target systems, and in transforming the accelerator-supersonic jet target concept into a radiation testing facility. A scoping assessment on the potential of a pulsed high-beta plasma device (dense plasma focus) is introduced to explore plasma concepts as near-term neutron and plasma radiation sources for the CTR Surface and Materials Program. (U.S.)

  6. Solar energy characteristics and some photovoltaic testing results in Jeddah

    Energy Technology Data Exchange (ETDEWEB)

    Mosalam Shaltout, M A

    1986-01-01

    The data for global radiation were analysed to investigate the correlation with climatological factors. Solar cell module testing under Jeddah climatic conditions was initiated in 1984-1985. The goal of this work was to study the performance and reliability of a commercially-available module in outdoor conditions in order to obtain information on solar cell system design, and to observe the influence of our specific climate conditions on module energy output. The use of results obtained for precise system sizing is discussed.

  7. New theoretical results in synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Bagrov, V.G. [Tomsk State University, Lenin Avenue 36, 634050 Tomsk (Russian Federation)]. E-mail: bagrov@phys.tsu.ru; Gitman, D.M. [Instituto de Fisica, Universidade de Sao Paulo, C.P. 66318, 05315-970 Sao Paulo, SP (Brazil); Tlyachev, V.B. [Tomsk Institute of High Current Electronics, Akademicheskiy Avenue 4, Tomsk (Russian Federation); Jarovoi, A.T. [Tomsk State University, Lenin Avenue 36, 634050 Tomsk (Russian Federation)

    2005-11-15

    One of the remarkable features of the relativistic electron synchrotron radiation is its concentration in small angle {delta}{approx}1/{gamma} (here {gamma}-relativistic factor: {gamma}=E/mc{sup 2}, E - energy, m - electron rest mass, c - light velocity) near rotation orbit plane [V.G. Bagrov, V.A. Bordovitsyn, V.G. Bulenok, V. Ya. Epp, Kinematical projection of pulsar synchrotron radiation profiles, in: Proceedings of IV ISTC Scientific Advisory Commitee Seminar on Basic Science in ISTC Aktivities, Akademgorodok, Novosibirsk, April 23-27, 2001, p. 293-300]. This theoretically predicted and experimentally confirmed feature is peculiar to total (spectrum summarized) radiating intensity. This angular distribution property has been supposed to be (at least qualitatively) conserved and for separate spectrum synchrotron radiation components. In the work of V.G. Bagrov, V.A. Bordovitsyn, V. Ch. Zhukovskii, Development of the theory of synchrotron radiation and related processes. Synchrotron source of JINR: the perspective of research, in: The Materials of the Second International Work Conference, Dubna, April 2-6, 2001, pp. 15-30 and in Angular dependence of synchrotron radiation intensity. http://lanl.arXiv.org/abs/physics/0209097, it is shown that the angular distribution of separate synchrotron radiation spectrum components demonstrates directly inverse tendency - the angular distribution deconcentration relatively the orbit plane takes place with electron energy growth. The present work is devoted to detailed investigation of this situation. For exact quantitative estimation of angular concentration degree of synchrotron radiation the definition of radiation effective angle and deviation angle is proposed. For different polarization components of radiation the dependence of introduced characteristics was investigated as a functions of electron energy and number of spectrum component.

  8. RESULTS OF IMPLEMENTATION OF TARGET PROGRAMS ON RADIATION ACCIDENT REMEDIATION FOR THE PERIOD TO 2010 AND PROSPECTS OF FURTHER ACTIVITIES

    Directory of Open Access Journals (Sweden)

    T. A. Marchenko

    2008-01-01

    Full Text Available The report contains information about measures undertaken by the Ministry of Civil Defense and Emergencies of the Russian Federation in the framework of implementation of the state policy in the field of radiation accidents remediation. Results of works realized in the framework of target programs on remediation of radiation accidents at Chernobyl NPP and Production Association MAYAK, and on problems caused by nuclear weapon tests at Seminalatinsk test site are presented.

  9. Standards for Radiation Effects Testing: Ensuring Scientific Rigor in the Face of Budget Realities and Modern Device Challenges

    Science.gov (United States)

    Lauenstein, J M.

    2015-01-01

    An overview is presented of the space radiation environment and its effects on electrical, electronic, and electromechanical parts. Relevant test standards and guidelines are listed. Test standards and guidelines are necessary to ensure best practices, minimize and bound systematic and random errors, and to ensure comparable results from different testers and vendors. Test standards are by their nature static but exist in a dynamic environment of advancing technology and radiation effects research. New technologies, failure mechanisms, and advancement in our understanding of known failure mechanisms drive the revision or development of test standards. Changes to standards must be weighed against their impact on cost and existing part qualifications. There must be consensus on new best practices. The complexity of some new technologies exceeds the scope of existing test standards and may require development of a guideline specific to the technology. Examples are given to illuminate the value and limitations of key radiation test standards as well as the challenges in keeping these standards up to date.

  10. Modeling UV Radiation Feedback from Massive Stars. I. Implementation of Adaptive Ray-tracing Method and Tests

    Science.gov (United States)

    Kim, Jeong-Gyu; Kim, Woong-Tae; Ostriker, Eve C.; Skinner, M. Aaron

    2017-12-01

    We present an implementation of an adaptive ray-tracing (ART) module in the Athena hydrodynamics code that accurately and efficiently handles the radiative transfer involving multiple point sources on a three-dimensional Cartesian grid. We adopt a recently proposed parallel algorithm that uses nonblocking, asynchronous MPI communications to accelerate transport of rays across the computational domain. We validate our implementation through several standard test problems, including the propagation of radiation in vacuum and the expansions of various types of H II regions. Additionally, scaling tests show that the cost of a full ray trace per source remains comparable to that of the hydrodynamics update on up to ∼ {10}3 processors. To demonstrate application of our ART implementation, we perform a simulation of star cluster formation in a marginally bound, turbulent cloud, finding that its star formation efficiency is 12% when both radiation pressure forces and photoionization by UV radiation are treated. We directly compare the radiation forces computed from the ART scheme with those from the M 1 closure relation. Although the ART and M 1 schemes yield similar results on large scales, the latter is unable to resolve the radiation field accurately near individual point sources.

  11. Utilization of radiation in non destructive tests

    International Nuclear Information System (INIS)

    Lopes, R.T.; Jesus, E.F.O. de; Junqueira, M.M.; Matos, J.A. de; Castello Branco, L.M.; Barros Junior, J.D.; Borges, J.C.

    1987-01-01

    The Nuclear Instrumentation Laboratory from COPPE/UFRJ has been developed techniques for using nuclear radiations to obtain images for non-destructive materials testing and medicine. With this objective, some prototypes of transmission computerized tomography systems using parallel beans and fan beans, with computer automation, including the mathematical process of image reprocessing and presentation in videos or printers are constructed [pt

  12. Radiation exposures of workers resulting from the transport of gamma radiography sources in Germany

    International Nuclear Information System (INIS)

    Sentuc, F.N.; Schwarz, G.

    2006-01-01

    Gamma radiation sources are widely used for industrial purposes e.g. for non-destructive material testing. Many of these sources are permanently installed at a facility within instruments e.g. for level or thickness gauging. Other radioactive sources are implemented in portable devices for industrial gamma radiography which have to be carried to the various remote usage sites. In Germany, approximately 20 000 - 25 000 shipments of gamma radiography sources are proceeding annually on public transport routes. Since routine radiation monitoring programmes do not permit task-specific determination of occupational doses e.g. doses incurred during the movement phase and handling related doses, work has been carried out with the objective to determine the radiation exposures of the personnel attributable to transportation. For this purpose, a survey was launched in 2005 collecting data about e.g. the number and conditions of transports, the activity and type of transported radiation sources and the radiation level within the driver's cab to allow a dose assessment to be made for transport workers. The results of this survey covering the most important companies for gamma radiography services in Germany are presented in this paper. (authors)

  13. Radiation exposures from nuclear tests at the Nevada Test Site

    Energy Technology Data Exchange (ETDEWEB)

    Dunning, G M

    1958-12-01

    A summary of the pertinent data on radiation exposures from nuclear tests in Nevada is presented. The data are presented in categories of external ..gamma.. radiation, activity concentrations in air, and activity concentrations in water. Methods used to estimate exposure and to evaluate data are described. The data are tabulated. The maximum external exposure was 7 to 8 r for 15 persons involved. In terms of relatively large populations, the average exposure for the 1,000,000 people living nearest the site was at the rate of 1/2 r/30 yr. The highest concentration of fallout activity in the air was about 1.3 ..mu..c/m/sup 3/ averaged over the 30 hr that the activity was present in significant quantities. The highest concentration of fallout activity in a potential drinking water supply was about 1.4 x 10/sup -/ ..mu..c/me extrapolated to D + 3 days. Evaluation of these data is given.

  14. The assessment of radiation exposures in native American communities from nuclear weapons testing in Nevada

    International Nuclear Information System (INIS)

    Frohmberg, E.; Goble, R.; Sanchez, V.; Quigley, D.

    2000-01-01

    Native Americans residing in a broad region downwind from the Nevada Test Site during the 1950s and 1960s received significant radiation exposures from nuclear weapons testing. Because of differences in diet, activities, and housing, their radiation exposures are only very imperfectly represented in the Department of Energy dose reconstructions. There are important missing pathways, including exposures to radioactive iodine from eating small game. The dose reconstruction model assumptions about cattle feeding practices across a year are unlikely to apply to the native communities as are other model assumptions about diet. Thus exposures from drinking milk and eating vegetables have not yet been properly estimated for these communities. Through consultations with members of the affected communities, these deficiencies could be corrected and the dose reconstruction extended to Native Americans. An illustration of the feasibility of extending the dose reconstruction is provided by a sample calculation to estimate radiation exposures to the thyroid from eating radio-iodine-contaminated rabbit thyroids after the Dedan test. The illustration is continued with a discussion of how the calculation results may be used to make estimates for other tests and other locations

  15. Design and Testing of an Active Heat Rejection Radiator with Digital Turn-Down Capability

    Science.gov (United States)

    Sunada, Eric; Birur, Gajanana C.; Ganapathi, Gani B.; Miller, Jennifer; Berisford, Daniel; Stephan, Ryan

    2010-01-01

    NASA's proposed lunar lander, Altair, will be exposed to vastly different external environment temperatures. The challenges to the active thermal control system (ATCS) are compounded by unfavorable transients in the internal waste heat dissipation profile: the lowest heat load occurs in the coldest environment while peak loads coincide with the warmest environment. The current baseline for this fluid is a 50/50 inhibited propylene glycol/water mixture with a freeze temperature around -35 C. While the overall size of the radiator's heat rejection area is dictated by the worst case hot scenario, a turn-down feature is necessary to tolerate the worst case cold scenario. A radiator with digital turn-down capability is being designed as a robust means to maintain cabin environment and equipment temperatures while minimizing mass and power consumption. It utilizes active valving to isolate and render ineffective any number of parallel flow tubes which span across the ATCS radiator. Several options were assessed in a trade-study to accommodate flow tube isolation and how to deal with the stagnant fluid that would otherwise remain in the tube. Bread-board environmental tests were conducted for options to drain the fluid from a turned-down leg as well an option to allow a leg to freeze/thaw. Each drain option involved a positive displacement gear pump with different methods of providing a pressure head to feed it. Test results showed that a start-up heater used to generate vapor at the tube inlet held the most promise for tube evacuation. Based on these test results and conclusions drawn from the trade-study, a full-scale radiator design is being worked for the Altair mission profile.

  16. Radiation exposure as a result of radioactivity in the vicinity of nuclear installations

    International Nuclear Information System (INIS)

    Van As, Deodandus.

    1975-11-01

    The nuclear industry in South Africa is expected to expand dramatically and, as a result, the effects of radioactive effluent from these installations on the environment will be of great practical and scientific importance. The long-term effects of low-level radiation cannot be clinically predicted; physical determination and prediction is therefore the accepted measure of radiation exposure. This study includes a survey of all forms of natural and man-made radiation to which the general public is constantly exposed. An intensive study was made of radioactive fallout over South Africa from nuclear bomb tests. From this the general radiation exposure of the South African public could be calculated. It also led to valuable scientific information on mesometeorology and health physics. The latter includes the relationship between air concentration and deposition, the transfer of airborne iodine-131 to milk, and the accumulation of strontium-90 and cesium-137 in human beings as a result of their diets. Thorough environmental studies were conducted at existing nuclear installation sites i.e. Pelinbada which is the site of the National Nuclear Research Centre and Dynefontein which is the proposed site of South Africa's first nuclear power station. These included meso-meteorology, atmospheric dispersion by means of neutron-activable tracers, accumulation factors for important radionuclides in edible marine species by means of stable element tracers, population surveys, background radioactivity surveys etc. From these results critical exposure pathways were established for both sites and the relationship between effluent release and radiation dose to the public was determined. This has lead to the establishment of maximum permissible releases for the operation of the SAFARI-1 research reactor by the Atomic Energy Board and for the specifications of the proposed Koeberg power reactors to be operated by the Electricity Supply Commission at Dynefontein [af

  17. Radiation doses to local populations near nuclear weapons test sites worldwide.

    Science.gov (United States)

    Simon, Steven L; Bouville, André

    2002-05-01

    Nuclear weapons testing was conducted in the atmosphere at numerous sites worldwide between 1946 and 1980, which resulted in exposures to local populations as a consequence of fallout of radioactive debris. The nuclear tests were conducted by five nations (United States, Soviet Union, United Kingdom, France, and China) primarily at 16 sites. The 16 testing sites, located in nine different countries on five continents (plus Oceania) contributed nearly all of the radioactive materials released to the environment by atmospheric testing; only small amounts were released at a fewother minor testing sites. The 16 sites discussed here are Nevada Test Site, USA (North American continent), Bikini and Enewetak, Marshall Islands (Oceania); Johnston Island, USA (Oceania), Christmas and Malden Island, Kiribati (Oceania); Emu Field, Maralinga, and Monte Bello Islands, Australia (Australian continent); Mururoa and Fangataufa, French Polynesia (Oceania), Reggane, Algeria (Africa), Novaya Zemlya and Kapustin Yar, Russia (Europe), Semipalatinsk, Kazakhstan (Asia), and Lop Nor, China (Asia). There were large differences in the numbers of tests conducted at each location and in the total explosive yields. Those factors, as well as differences in population density, lifestyle, environment, and climate at each site, led to large differences in the doses received by local populations. In general, the tests conducted earliest led to the highest individual and population exposures, although the amount of information available for a few of these sites is insufficient to provide any detailed evaluation of radiation exposures. The most comprehensive information for any site is for the Nevada Test Site. The disparities in available information add difficulty to determining the radiation exposures of local populations at each site. It is the goal of this paper to summarize the available information on external and internal doses received by the public living in the regions near each of the

  18. Personal Radiation Detector Field Test and Evaluation Campaign

    International Nuclear Information System (INIS)

    Chris A. Hodge, Ding Yuan, Raymond P. Keegan, Michael A. Krstich

    2007-01-01

    Following the success of the Anole test of portable detection system, the U.S. Department of Homeland Security (DHS) Domestic Nuclear Detection Office organized a test and evaluation campaign for personal radiation detectors (PRDs), also known as 'Pagers'. This test, 'Bobcat', was conducted from July 17 to August 8, 2006, at the Nevada Test Site. The Bobcat test was designed to evaluate the performance of PRDs under various operational scenarios, such as pedestrian surveying, mobile surveying, cargo container screening, and pedestrian chokepoint monitoring. Under these testing scenarios, many operational characteristics of the PRDs, such as gamma and neutron sensitivities, positive detection and false alarm rates, response delay times, minimum detectable activities, and source localization errors, were analyzed. This paper will present the design, execution, and methodologies used to test this equipment for the DHS

  19. Environmental radiation at the Monte Bello Islands from nuclear weapons tests conducted in 1952 and 1956

    International Nuclear Information System (INIS)

    Moroney, J.R.; Cooper, M.B.

    1982-12-01

    The results from the 1962 and 1968 surveys of environmental radiation at the Monte Bello Islands are presented. These were the first of the series of surveys of radioactive contamination of the Islands to be carried out following nuclear weapons tests conducted in 1952 and 1956. Detailed comparison is made with the results obtained in the subsequent surveys in 1972 and 1978. For more than 20 years, no area at the Monte Bello Islands has presented an acute hazard due to external exposure to environmental radiation

  20. Test reference year generation from meteorological and simulated solar radiation data

    Energy Technology Data Exchange (ETDEWEB)

    Miguel, A. de; Bilbao, J. [University of Valladolid (Spain). Dept. of Applied Physics

    2005-06-01

    In this paper, a new method for generating test reference year (TRY) from the measured meteorological variables is proposed. Hourly recorded data of air temperature, relative humidity and wind velocity for two stations, Valladolid and Madrid (Spain) were selected to develop the method and a TRY was obtained. Monthly average solar radiation values were calculated taking into account the temperature and solar radiation correlations. Four different methodologies were used to evaluate hourly global solar radiation from hourly weather data of temperature and, as a consequence, four different TRYs with common data sets of temperature, relative humidity and wind velocity were generated for Valladolid and Madrid (Spain) stations. In order to evaluate the four different methodologies, TRYs data were compared with long-term measured data series using statistical estimators such as average, standard deviation, root mean square error (rmse) and mean bias error (mbe). Festa and Ratto and the TAG model, from Aguiar and Collares-Pereira, respectively, turned out to be the best methods for generating hourly solar irradiation data. The best performance was shown by the TRY0 year which was based on the solar radiation models mentioned above. The results show that the best reference year for each site varies with the season and the characteristics of the station. (author)

  1. Test beam performance of a tracking TRD [Transition Radiation Detector] prototype

    International Nuclear Information System (INIS)

    Shank, J.T.; Whitaker, J.S.; Polychronakos, V.A.; Radeka, V.; Stephani, D.; Beker, H.; Bock, R.K.; Botlo, M.; Fabjan, C.W.; Pfennig, J.; Price, M.J.; Willis, W.J.; Akesson, T.; Chernyatin, V.; Dolgoshein, B.; Nevsky, P.; Potekhin, M.; Romanjuk, A.; Sosnovtsev, V.; Gavrilenko, I.; Muravjev, S.; Shmeleva, A.

    1990-01-01

    A Tracking Transition Radiation Detector prototype has been constructed and tested. It consists of 240 straw tubes, 4 mm in diameter, imbedded in a polyethylene block acting as the radiator. Its performance as an electron identifier as well as a tracking device for minimum ionizing particles has been determined. 2 refs., 6 figs

  2. Behaviour parameters of rats in the 'Open field' test under combined effect of radiation and non-radiation factors

    International Nuclear Information System (INIS)

    Kadukova, E.M.; Stashkevich, D.G.; Naumov, A.D.; Kuts, F.I.

    2015-01-01

    It was shown that exposure of electromagnetic radiation and emotional stress modifies the level of integrative reaction of CNS rats which were exposed to ionizing radiation in the 'Open field' test. (authors)

  3. Electromagnetic radiation and behavioural response of ticks: an experimental test.

    Science.gov (United States)

    Vargová, Blažena; Majláth, Igor; Kurimský, Juraj; Cimbala, Roman; Kosterec, Michal; Tryjanowski, Piotr; Jankowiak, Łukasz; Raši, Tomáš; Majláthová, Viktória

    2018-05-01

    Factors associated with the increased usage of electronic devices, wireless technologies and mobile phones nowadays are present in increasing amounts in our environment. All living organisms are constantly affected by electromagnetic radiation which causes serious environmental pollution. The distribution and density of ticks in natural habitats is influenced by a complex of abiotic and biotic factors. Exposure to radio-frequency electromagnetic field (RF-EMF) constitutes a potential cause altering the presence and distribution of ticks in the environment. Our main objective was to determine the affinity of Dermacentor reticulatus ticks towards RF-EMF exposure. Originally designed and constructed radiation-shielded tube (RST) test was used to test the affinity of ticks under controlled laboratory conditions. All test were performed in an electromagnetic compatibility laboratory in an anechoic chamber. Ticks were irradiated using a Double-Ridged Waveguide Horn Antenna to RF-EMF at 900 and 5000 MHz, 0 MHz was used as control. The RF-EMF exposure to 900 MHz induced a higher concentration of ticks on irradiated arm of RST as opposed to the RF-EMF at 5000 MHz, which caused an escape of ticks to the shielded arm. This study represents the first experimental evidence of RF-EMF preference in D. reticulatus. The projection of obtained results to the natural environment could help assess the risk of tick borne diseases and could be a tool of preventive medicine.

  4. Radiation Testing at Sandia National Laboratories: Sandia – JPL Collaboration for Europa Lander

    Energy Technology Data Exchange (ETDEWEB)

    Hattar, Khalid Mikhiel [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Ion Beam Lab.; Olszewska-Wasiolek, Maryla Aleksandra [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Gamma Irradiation Facility

    2017-01-01

    Sandia National Laboratories (SNL) is assisting Jet Propulsion Laboratory in undertaking feasibility studies and performance assessments for the Planetary Protection aspect of the Europa Lander mission. The specific areas of interest for this project are described by task number. This white paper presents the evaluation results for Task 2, Radiation Testing, which was stated as follows: Survey SNL facilities and capabilities for simulating the Europan radiation environment and assess suitability for: A. Testing batteries, electronics, and other component and subsystems B. Exposing biological organisms to assess their survivability metrics. The radiation environment the Europa Lander will encounter on route and in orbit upon arrival at its destination consists primarily of charged particles, energetic protons and electrons with the energies up to 1 GeV. The charged particle environments can be simulated using the accelerators at the Ion Beam Laboratory. The Gamma Irradiation Facility and its annex, the Low Dose Rate Irradiation Facility, offer irradiations using Co-60 gamma sources (1.17 and 1.33 MeV), as well as Cs-137 gamma (0.661 MeV) AmBe neutron (0-10 MeV) sources.

  5. Online fault diagnostics and testing of area gamma radiation monitor using wireless network

    Science.gov (United States)

    Reddy, Padi Srinivas; Kumar, R. Amudhu Ramesh; Mathews, M. Geo; Amarendra, G.

    2017-07-01

    Periodical surveillance, checking, testing, and calibration of the installed Area Gamma Radiation Monitors (AGRM) in the nuclear plants are mandatory. The functionality of AGRM counting electronics and Geiger-Muller (GM) tube is to be monitored periodically. The present paper describes the development of online electronic calibration and testing of the GM tube from the control room. Two electronic circuits were developed, one for AGRM electronic test and another for AGRM detector test. A dedicated radiation data acquisition system was developed using an open platform communication server and data acquisition software. The Modbus RTU protocol on ZigBee based wireless communication was used for online monitoring and testing. The AGRM electronic test helps to carry out the three-point electronic calibration and verification of accuracy. The AGRM detector test is used to verify the GM threshold voltage and the plateau slope of the GM tube in-situ. The real-time trend graphs generated during these tests clearly identified the state of health of AGRM electronics and GM tube on go/no-go basis. This method reduces the radiation exposures received by the maintenance crew and facilitates quick testing with minimum downtime of the instrument.

  6. Results of radiation therapy in periarthritis humeroscapularis

    International Nuclear Information System (INIS)

    Schultze, J.; Schlichting, G.; Galalae, R.; Kimmig, B.; Koltze, H.

    2004-01-01

    Background: radiation therapy is applied in painful degenerative shoulder diseases. Aim of this work was to evaluate the contribution of radiation therapy to symptomatic improvement in periarthritis humeroscapularis. Methods: ninety-four patients with periarthritis humeroscapularis were treated in two institutions. Mean age was 68 years, sex distribution were 32 men and 62 women. In 58 cases the right side was affected, left in 36 cases. At single doses of 0,75 Gy once a week a total dose of 6 Gy was applied The treatment effect was evaluated by the standardized von Pannewitz-score at the end of the treatment up to 6 months thereafter. Results: the treatment results of all the 94 patients were documentated at the end of therapy. Seventy-one patients were followed at least for further 4 months. Radiogenic side-effects were not noticed. The symptoms of 54 patients (57.4%) were improved or vanished, in 40 cases the symptoms were not significantly affected (42.6%). Four months after therapy 42 of 71 patients were improved (59.2%), 29 unchanged (40.8%). The treatment effect occured typically up to 2 months after therapy, there were no age-related differences. Also in recurrent radiation therapies the symptoms improved, in 80 percent after one preceding therapy, however only in 31.2 percent after multiple prior radiotherapies. (orig.)

  7. Non Volatile Flash Memory Radiation Tests

    Science.gov (United States)

    Irom, Farokh; Nguyen, Duc N.; Allen, Greg

    2012-01-01

    Commercial flash memory industry has experienced a fast growth in the recent years, because of their wide spread usage in cell phones, mp3 players and digital cameras. On the other hand, there has been increased interest in the use of high density commercial nonvolatile flash memories in space because of ever increasing data requirements and strict power requirements. Because of flash memories complex structure; they cannot be treated as just simple memories in regards to testing and analysis. It becomes quite challenging to determine how they will respond in radiation environments.

  8. Evaluation of testing strategies for the radiation tolerant ATLAS n **+-in-n pixel sensor

    CERN Document Server

    Klaiber Lodewigs, Jonas M

    2003-01-01

    The development of particle tracker systems for high fluence environments in new high-energy physics experiments raises new challenges for the development, manufacturing and reliable testing of radiation tolerant components. The ATLAS pixel detector for use at the LHC, CERN, is designed to cover an active sensor area of 1.8 m**2 with 1.1 multiplied by 10 **8 read-out channels usable for a particle fluence up to 10 **1**5 cm**-**2 (1 MeV neutron equivalent) and an ionization dose up to 500 kGy of mainly charged hadron radiation. To cope with such a harsh environment the ATLAS Pixel Collaboration has developed a radiation hard n **+-in-n silicon pixel cell design with a standard cell size of 50 multiplied by 400 mum**2. Using this design on an oxygenated silicon substrate, sensor production has started in 2001. This contribution describes results gained during the development of testing procedures of the ATLAS pixel sensor and evaluates quality assurance procedures regarding their relevance for detector operati...

  9. Results from a Test Fixture for button BPM Trapped Mode Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Cameron,P.; Bacha, B.; Blednykh, A.; Pinayev, I.; Singh, O.

    2009-05-04

    A variety of measures have been suggested to mitigate the problem of button BPM trapped mode heating. A test fixture, using a combination of commercial-off-the-shelf and custom machined components, was assembled to validate the simulations. We present details of the fixture design, measurement results, and a comparison of the results with the simulations. A brief history of the trapped mode button heating problem and a set of design rules for BPM button optimization are presented elsewhere in these proceedings. Here we present measurements on a test fixture that was assembled to confirm, if possible, a subset of those rules: (1) Minimize the trapped mode impedance and the resulting power deposited in this mode by the beam. (2) Maximize the power re-radiated back into the beampipe. (3) Maximize electrical conductivity of the outer circumference of the button and minimize conductivity of the inner circumference of the shell, to shift power deposition from the button to the shell. The problem is then how to extract useful and relevant information from S-parameter measurements of the test fixture.

  10. Test of the linear-no threshold theory of radiation carcinogenesis

    International Nuclear Information System (INIS)

    Cohen, B.L.

    1998-01-01

    It is shown that testing the linear-no threshold theory (L-NT) of radiation carcinogenesis is extremely important and that lung cancer resulting from exposure to radon in homes is the best tool for doing this. A study of lung cancer rates vs radon exposure in U.S. Counties, reported in 1975, is reviewed. It shows, with extremely powerful statistics, that lung cancer rates decrease with increasing radon exposure, in sharp contrast to the prediction of L-NT, with a discrepancy of over 20 standard deviations. Very extensive efforts were made to explain an appreciable part of this discrepancy consistently with L-NT, with no success; it was concluded that L-NT fails, grossly exaggerating the cancer risk of low level radiation. Two updating studies reported in 1996 are also reviewed. New updating studies utilizing more recent lung cancer statistics and considering 450 new potential confounding factors are reported. All updates reinforce the previous conclusion, and the discrepancy with L-NT is increased. (author)

  11. Radiation monitoring for the HTTR rise-to-power test (1) and (2)'

    Energy Technology Data Exchange (ETDEWEB)

    Nakazawa, Takashi; Yoshino, Toshiaki; Yasu, Katsuji; Ashikagaya, Yoshinobu; Kikuchi, Toshiki [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment

    2001-02-01

    The High Temperature Engineering Test Reactor (HTTR) is the first high temperature gas-cooled research reactor in Japan. This reactor is a helium-gas-cooled and graphite-moderated reactor with a thermal output of 30 MW. The rated operation temperature of the outlet coolant is 850degC. (During high temperature test operation, this reaches 950degC). The first criticality of the HTTR was attained in November 1998. The single loaded, parallel loaded operation with a thermal output of 9 MW (called the HTTR Rise-to-Power Test (1)) was completed between September 16, 1999 and July 8, 2000. The single loaded, parallel loaded continuous operation with a thermal output of 20 MW (called the HTTR Rise-to-Power Test (2)) has also been carried out, but it was shutdown at the halfway stage by a single from the reactor, when the thermal output was 16.5 MW and the reactor outlet coolant temperature was 500degC. This report describes the radiation monitoring carried out during the HTTR Rise-to-Power Tests (1) and (2)'. The data measured by the various radiation monitors is also reported. These data will be used for the estimation of radiation levels (such as the radiation dose equivalent rate, the radioactive concentration in effluents, etc.) for the next HTTR Rise-to-Power Test, and for periodic inspections. (author)

  12. Radiation exposure on residents due to semipalatinsk nuclear tests

    International Nuclear Information System (INIS)

    Takada, J.; Hoshi, M.; Nagatomo, T.

    2000-01-01

    Accumulated external radiation doses for residents near Semipalatinsk nuclear test site of the former USSR are presented as a results of the first study by thermoluminescence technique for bricks sampled at several settlements between 1995 and 1997. The external doses which we evaluated from brick dose were up to ∼100 cGy for resident. The external doses at several points in the center of Semipalatinsk city were ∼60 cGy that was remarkably high comparing with the previously reported value based on the military data. A total of 459 nuclear explosions were conducted by the former Union of Soviet Socialist Republics (USSR) from 1949 to 1989 at the Semipalatinsk nuclear test site (SNTS) Kazakhstan, including 87 atmospheric, 26 on the ground, and 364 underground explosions. Total energy release of about 18 Mt equivalent of trinitrotoluene is eleven hundreds times of Hiroshima atomic bomb. However previous reports concerning the effects of radiation on residents near the SNTS based on data provided by the Defense Department of the former USSR do not have direct experimental data concerning effective equivalent dose. They just measured some doses for particular settlements after some nuclear explosions. These do not indicate integrated dose for the residents due to the whole explosions. The technique of thermoluminescence dosimetry (TLD) which had been successfully applied to the dosimetry on Hiroshima and Nagasaki atomic bombs, enabled us to evaluate accumulated external gamma ray doses at specific places due to whole nuclear explosions in the Semipalatinsk test site. TLD technique is well-established one for not only instantaneous exposure like in A-bombs (Hiroshima and Nagasaki) but also prolonged exposure like in dating. Moreover this technique was applicable for dosimetry study of radioactive fallout as shown in studies of Chernobyl accident. The way of external dose estimation from TLD doses for brick will be discussed in case of radioactive fallout. We will

  13. Dynamic testing for radiation induced failures in a standard CMOS submicron technology pixel front-end

    International Nuclear Information System (INIS)

    Venuto, D. de; Corsi, F.; Ohletz, M.J.

    1999-01-01

    A testing method for the detection of performance degradation induced by high-dose irradiation in high-energy experiments has been developed. The method used is based on a fault signature generation defined on the basis of the state-space analysis for linear circuits. By sampling the response of the circuit under test (CUT) to a single rectangular pulse, a set of parameters α are evaluated which are functions of the circuit singularities and constitute a signature for the CUT. Amplitude perturbations of these parameters engendered by element drift failure indicate a possible faulty condition. The effects of radiation induced faults in the analogue CMOS front-end of a silicon pixel detector employed in high energy physics experiments has been investigated. The results show that, even for the 800 krad dose, the test devised is able to detect the degradation of the amplifier performances. The results show also that hardened devices do not necessarily produce high circuit immunity to radiation and the proposed test method provides a mean to detect these performance deviations and to monitor them during the operating life of the chip. (A.C.)

  14. Preliminary assays for lemongrass essential oil ecotoxicological test in D. similis and C. silvestrii submitted to gamma radiation

    International Nuclear Information System (INIS)

    Gimiliani, Giovana T.; Rogero, Sizue O.; Rogero, Jose R.; Cruz, Aurea S.

    2011-01-01

    Pharmaceutical products are of great interest in ecotoxicological studies due to being found some of these products in the superficial waters and sediments, water and sewage treatment effluents. It was verified an increase of insect repellent chemical products in the aquatic environment because of the increase of diseases transmitted by mosquitoes like dengue. As these compounds show toxicity, the use of essential oils natural products with repellent properties is increasing and the literature about the impact in the aquatic environment is scarce. The hydric frame would suffer natural radiation and radiations from energy generation nuclear plants impacts fall out of tests and nuclear accidents. There is no universal definition of environmental protection and there are few studies on radiation effects in the aquatic environment. In this study was determined the lemon grass essential oil toxicity level as well as the lethal dose of ionizing radiation, LD 50 , in aquatic organisms. Cytotoxicity test was performed by in vitro neutral red uptake method in NCTC clone L929 cell line. In the LD 50 test aquatic organisms were submitted to gamma radiation. The essential oil of lemongrass Cymbopogon flexuosus showed cytotoxicity index IC 50 about 50μg.mL -1 . The LD 50 for Daphnia similis was 242 Gy and Ceriodaphnia silvestrii about 525 Gy. Studies will be continued with acute and chronic ecotoxicological tests of lemongrass essential oil in natural organisms and in organisms submitted to gamma radiation, utilizing the results obtained in this work. (author)

  15. NASA Space Radiation Risk Project: Overview and Recent Results

    Science.gov (United States)

    Blattnig, Steve R.; Chappell, Lori J.; George, Kerry A.; Hada, Megumi; Hu, Shaowen; Kidane, Yared H.; Kim, Myung-Hee Y.; Kovyrshina, Tatiana; Norman, Ryan B.; Nounu, Hatem N.; hide

    2015-01-01

    The NASA Space Radiation Risk project is responsible for integrating new experimental and computational results into models to predict risk of cancer and acute radiation syndrome (ARS) for use in mission planning and systems design, as well as current space operations. The project has several parallel efforts focused on proving NASA's radiation risk projection capability in both the near and long term. This presentation will give an overview, with select results from these efforts including the following topics: verification, validation, and streamlining the transition of models to use in decision making; relative biological effectiveness and dose rate effect estimation using a combination of stochastic track structure simulations, DNA damage model calculations and experimental data; ARS model improvements; pathway analysis from gene expression data sets; solar particle event probabilistic exposure calculation including correlated uncertainties for use in design optimization.

  16. Test of radiation hardness of pcCVD detectors

    Energy Technology Data Exchange (ETDEWEB)

    Schlemme, Steffen [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Technische Universitaet Darmstadt (Germany); Enders, Joachim [Technische Universitaet Darmstadt (Germany); Figuera, P.; Salamone, S. [LNS-INFN Catania (Italy); Fruehauf, J.; Kis, Mladen; Kratz, A.; Kurz, N.; Loechner, S.; Nociforo, Chiara; Schirru, Fabio; Szczepanczyk, B.; Traeger, M.; Visinka, R. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Musumarra, A. [LNS-INFN Catania (Italy); University of Catania (Italy)

    2016-07-01

    The new in-flight separator Super-FRS is under construction at the Facility for Antiproton and Ion Research (FAIR, Darmstadt). Ion rates up to 3 x 10{sup 11} {sup 238}U/spill demand an adaption of detectors to a high radiation environment. A test experiment to investigate the radiation hardness of polycrystalline diamond detectors (pcCVD) was performed at the LNS-INFN in Catania using a {sup 12}C beam at 62 MeV/u and intensities of up to 1.5 pnA. The setup consisted of pcCVD strip detectors to measure the beam profile, a single crystal diamond detector to calibrate the ionisation chamber working in current mode as a beam intensity monitor and a pcCVD sample to be irradiated. The IC used was designed for FAIR and showed a stable counting rate allowing us to calibrate and perform beam intensity measurements with it. The total measured counts on the sample were 8.25 x 10{sup 11} counts/mm{sup 2} over a period of 60 hours. Digital waveforms of the pcCVD signals were taken with an oscilloscope and analysed. The results showed no change of the pcCVD signal properties during the entire irradiation.

  17. CCTF CORE I test results

    International Nuclear Information System (INIS)

    Murao, Yoshio; Sudoh, Takashi; Akimoto, Hajime; Iguchi, Tadashi; Sugimoto, Jun; Fujiki, Kazuo; Hirano, Kenmei

    1982-07-01

    This report presents the results of the following CCTF CORE I tests conducted in FY. 1980. (1) Multi-dimensional effect test, (2) Evaluation model test, (3) FLECHT coupling test. On the first test, one-dimensional treatment of the core thermohydrodynamics was discussed. On the second and third tests, the test results were compared with the results calculated by the evaluation model codes and the results of the corresponding FLECHT-SET test (Run 2714B), respectively. The work was performed under contracts with the Atomic Energy Bureau of Science and Technology Agency of Japan. (author)

  18. Computer aided periodical and regulated service tests on radiation measuring systems

    International Nuclear Information System (INIS)

    Sandner, W.; Lin, R.; Rothhaupt, W.

    1994-01-01

    Measuring systems for radioactive radiation, which must be registered by official order, have to be tested periodically according to laid down rules (WKP). A strategy for a test-device was drawn up for a flexible adaption of the procedure to individual requests, but also for a standardization of the logical interface to the measuring system. Especially the interaction of testing and normal measuring procedures is clearly defined and transparent; the original functional parts of the measuring run are used during the test as far as possible. Adapation to individual requirements is controlled by ASCII-Files, so that the program code remains unchanged. The functional possibilities are extensive also for the inspections by customers and authorities. Due to the nearly automatical run of the procedure, including printout of the results, the tests are always comparable. The standard was checked by some actual projects, basede on SYSTEM 7000 (Thermo Instrument Systems GmbH) and PC runing under DOS. (orig.) [de

  19. Results of a first beam test of hadron blind trackers

    Energy Technology Data Exchange (ETDEWEB)

    Chen, M. (Laboratory for Nuclear Science, MIT, Cambridge, MA (United States)); Luckey, D. (Laboratory for Nuclear Science, MIT, Cambridge, MA (United States)); Smolin, M. (Laboratory for Nuclear Science, MIT, Cambridge, MA (United States)); Sumorok, K. (Laboratory for Nuclear Science, MIT, Cambridge, MA (United States)); Zhang, X. (Laboratory for Nuclear Science, MIT, Cambridge, MA (United States)); Bolozdynya, A. (ITEP, Moscow (Russian Federation)); Belogurov, S. (ITEP, Moscow (Russian Federation)); Churakov, D. (ITEP, Moscow (Russian Federation)); Koutchenkov, A. (ITEP, Moscow (Russian Federation)); Kovalenko, A. (ITEP, Moscow (Russian Federation)); Kuzichev, V. (ITEP, Moscow (Russian Federation)); Lebedenko, V. (ITEP, Moscow (Russian Federation)); Sheinkman, V. (ITEP, Moscow (Russian Federation)); Smirnov, G. (ITEP, Moscow (Russian Federation)); Safronov, G. (ITEP, Moscow (Russian Federation)); Vinogradov, V. (ITEP, Moscow (Russian Federation)); Giomataris, Y. (IPN,

    1994-07-15

    We describe the experimental results of a new type of electron tracker, called Hadron Blind Detector or HBD. An HBD prototype was tested with gas mixtures of CF[sub 4] with He or Ne and a parallel plate avalanche chamber having a CsI photocathode of eight pads. Beam tests confirm the large Cherenkov light bandwidth in the EUV region that can be obtained with such gas mixtures. It results in a large quality factor of about 500 cm[sup -1] which allows HBD operation with a much shorter radiator thickness than conventional Cherenkov counters. Full electron efficiency was obtained, while pions were rejected up to momenta of 9 GeV/c. HBD is unique in measuring electron trajectories near the vertex, vetoing Dalitz pairs, and providing trigger on electrons among heavy hadron background. We discuss the use of such detectors for lepton identification and detection in high energy physics experiments and especially in heavy ion colliders. ((orig.))

  20. Results of a first beam test of hadron blind trackers

    International Nuclear Information System (INIS)

    Chen, M.; Luckey, D.; Smolin, M.; Sumorok, K.; Zhang, X.; Bolozdynya, A.; Belogurov, S.; Churakov, D.; Koutchenkov, A.; Kovalenko, A.; Kuzichev, V.; Lebedenko, V.; Sheinkman, V.; Smirnov, G.; Safronov, G.; Vinogradov, V.; Giomataris, Y.; Joseph, C.; Werlen, M.; Charpak, G.; Blumenfeld, B.; Gougas, A.K.; Steele, D.; Akopyan, M.

    1994-01-01

    We describe the experimental results of a new type of electron tracker, called Hadron Blind Detector or HBD. An HBD prototype was tested with gas mixtures of CF 4 with He or Ne and a parallel plate avalanche chamber having a CsI photocathode of eight pads. Beam tests confirm the large Cherenkov light bandwidth in the EUV region that can be obtained with such gas mixtures. It results in a large quality factor of about 500 cm -1 which allows HBD operation with a much shorter radiator thickness than conventional Cherenkov counters. Full electron efficiency was obtained, while pions were rejected up to momenta of 9 GeV/c. HBD is unique in measuring electron trajectories near the vertex, vetoing Dalitz pairs, and providing trigger on electrons among heavy hadron background. We discuss the use of such detectors for lepton identification and detection in high energy physics experiments and especially in heavy ion colliders. ((orig.))

  1. Performance of CREAM Calorimeter Results of Beam Tests

    CERN Document Server

    Ahn, H S; Beatty, J J; Bigongiari, G; Castellina, A; Childers, J T; Conklin, N B; Coutu, S; Duvernois, M A; Ganel, O; Han, J H; Hyun, H J; Kang, T G; Kim, H J; Kim, K C; Kim, M Y; Kim, T; Kim, Y J; Lee, J K; Lee, M H; Lutz, L; Maestro, P; Malinine, A; Marrocchesi, P S; Mognet, S I; Nam, S W; Nutter, S; Park, N H; Park, H; Seo, E S; Sina, R; Syed, S; Song, C; Swordy, S; Wu, J; Yang, J; Zhang, H Q; Zei, R; Zinn, S Y

    2005-01-01

    The Cosmic Ray Energetics And Mass (CREAM), a balloon-borne experiment, is under preparation for a flight in Antarctica at the end of 2004. CREAM is planned to measure the energy spectrum and composition of cosmic rays directly at energies between 1 TeV and 1000 TeV. Incident particle energies will be measured by a transition radiation detector and a sampling calorimeter. The calorimeter was constructed at the University of Maryland and tested at CERN in 2003. Performance of the calorimeter during the beam tests is reported.

  2. Radiation exposure of inhabitants around Semipalatinsk nuclear weapon test site

    International Nuclear Information System (INIS)

    Takada, Jun; Hoshi, Masaharu

    1997-01-01

    This paper described and reviewed the data reported by Russia and Kazakhstan and authors' studies on the exposed doses as follows. History of nuclear explosion tests in Semipalatinsk: From 1949 to 1989 in old Russia, 459 explosion tests involving 26 on the ground, 87 in the air and 346 in underground were performed, of which TNT equivalence was 0.6 Mt, 6 Mt and 11 Mt, respectively. A mystery in the reports of radiation doses by Russia and Kazakhstan. Present status of the regions after the end of nuclear weapon tests: Environment radiation doses in μSv/h in following regions were 0.06 in Mostik, 0.1 in Dolon and Semipalatinsk, 0.07 in Izvyestka and Znamenka, 0.08 in Tchagan and 21 in Atomic Lake. Evaluation of external exposure dose of the living regions with thermoluminescence method: External exposure dose was estimated to be about 90 cGy in a certain village and 40 cGy in Semipalatinsk which being 150 km far from the test site. (K.H.)

  3. Activities of the Institute of Radiation Protection and Dosimetry on radiation overexposure analysis - results from 1994 to 1997

    International Nuclear Information System (INIS)

    Silva, Francisco C.A. da; Ramalho, Adriana

    1999-01-01

    Since 1985 the Institute of Radiation Protection and Dosimetry has operated a service carried out by a multi-disciplinary Group called Radiation Overexposure analysis Group - GADE. It is composed of specialists in radiation protection and dosimetry and has the main objective of taking coordinated actions on radiation overexposure cases. This paper shows mainly the results got from 1984 to 1997 with the methodology used. It was observed that the cases are falling down due to radiation protection activities in the installation. (author)

  4. Environmental Radiation Surveillance Results from over the Last Decade of Operational Experience at the Regional Radiation Monitoring Stations(RRMS)

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hae Young [Daegu Regional Radiation Monitoring Station, Daegu (Korea, Republic of); Yoo, Dong Han [Ulsan Regional Radiation Monitoring Station, Ulsan (Korea, Republic of); Lee, Sang Hoon [Kyungpook National University, Daegu (Korea, Republic of)

    2015-10-15

    The objectives of the current program are to monitor environmental radiation/radioactivity level in Korea and to provide the base-line data on environmental radiation/radioactivity which will be useful in the case of radiological emergency situations. This program plays an important role in the view of protecting the public health against the potential hazards of radiation and maintaining a clean environment. This paper describes an introduction to the Regional Radiation Monitoring Stations (RRMS), and also presents some results of recent years (2001-2014). The environmental radiation surveillance results of years 2001-2014 have been described. It indicates normal levels of radiation in the past years. These kinds of studies are very important in providing references in understanding the environmental radioactivity level in a particular region.

  5. Results of the quality assurance testing program for radiopharmaceuticals 1995

    Energy Technology Data Exchange (ETDEWEB)

    Baldas, J.; Binnyman, J.; Ivanov, Z.; Lauder, R.

    1996-07-01

    The results of the quality assurance testing conducted by the Australian Radiation Laboratory is summarised. Overall 111 batches of 27 different types of radiopharmaceuticals were tested on samples obtained through normal commercial channels. Failure to meet full specifications was observed in 10 of the 111 batches. All technetium-99m cold kits were reconstituted according to the directions in the package insert using sodium pertechnetate ( {sup 99m}Tc) injection. Radionuclidic purity has been determined at the calibration time, except for Thallous [{sup 201}Tl] Chloride injection where the highest impurity level up to product expiry is quoted. Non-compliance of the vial label was observed in one of the ten batches failing specification and was the sole cause of product failure for this batch. Vial label non-compliance consisted of, absence of volume in the vial. Six batches failed the biodistribution test but in no case did this involve failure of the distribution for the target organs. tabs.

  6. Results of the quality assurance testing program for radiopharmaceuticals 1995

    International Nuclear Information System (INIS)

    Baldas, J.; Binnyman, J.; Ivanov, Z.; Lauder, R.

    1996-07-01

    The results of the quality assurance testing conducted by the Australian Radiation Laboratory is summarised. Overall 111 batches of 27 different types of radiopharmaceuticals were tested on samples obtained through normal commercial channels. Failure to meet full specifications was observed in 10 of the 111 batches. All technetium-99m cold kits were reconstituted according to the directions in the package insert using sodium pertechnetate ( 99m Tc) injection. Radionuclidic purity has been determined at the calibration time, except for Thallous [ 201 Tl] Chloride injection where the highest impurity level up to product expiry is quoted. Non-compliance of the vial label was observed in one of the ten batches failing specification and was the sole cause of product failure for this batch. Vial label non-compliance consisted of, absence of volume in the vial. Six batches failed the biodistribution test but in no case did this involve failure of the distribution for the target organs. tabs

  7. A critical experimental test of synchrotron radiation theory with 3rd generation light source

    International Nuclear Information System (INIS)

    Geloni, Gianluca; Kocharyan, Vitali; Saldin, Evgeni

    2016-05-01

    A recent ''beam splitting'' experiment at LCLS apparently demonstrated that after a microbunched electron beam is kicked on a large angle compared to the divergence of the FEL radiation, the microbunching wave front is readjusted along the new direction of motion of the kicked beam. Therefore, coherent radiation from an undulator placed after the kicker is emitted along the kicked direction without suppression. This strong emission of coherent undulator radiation in the kicked direction cannot be explained in the framework of conventional synchrotron radiation theory. In a previous paper we explained this puzzle. We demonstrated that, in accelerator physics, the coupling of fields and particles is based, on the one hand, on the use of results from particle dynamics treated according to the absolute time convention and, on the other hand, on the use of Maxwell equations treated according to the standard (Einstein) synchronization convention. Here lies the misconception which led to the strong qualitative disagreement between theory and experiment. After the ''beam splitting'' experiment at LCLS, it became clear that the conventional theory of synchrotron radiation cannot ensure the correct description of coherent and spontaneous emission from a kicked electron beam, nor the emission from a beam with finite angular divergence, in an undulator or a bending magnet. However, this result requires further experimental confirmation. In this publication we propose an uncomplicated and inexpensive experiment to test synchrotron radiation theory at 3rd generation light sources.

  8. A critical experimental test of synchrotron radiation theory with 3rd generation light source

    Energy Technology Data Exchange (ETDEWEB)

    Geloni, Gianluca [European XFEL GmbH, Hamburg (Germany); Kocharyan, Vitali; Saldin, Evgeni [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2016-05-15

    A recent ''beam splitting'' experiment at LCLS apparently demonstrated that after a microbunched electron beam is kicked on a large angle compared to the divergence of the FEL radiation, the microbunching wave front is readjusted along the new direction of motion of the kicked beam. Therefore, coherent radiation from an undulator placed after the kicker is emitted along the kicked direction without suppression. This strong emission of coherent undulator radiation in the kicked direction cannot be explained in the framework of conventional synchrotron radiation theory. In a previous paper we explained this puzzle. We demonstrated that, in accelerator physics, the coupling of fields and particles is based, on the one hand, on the use of results from particle dynamics treated according to the absolute time convention and, on the other hand, on the use of Maxwell equations treated according to the standard (Einstein) synchronization convention. Here lies the misconception which led to the strong qualitative disagreement between theory and experiment. After the ''beam splitting'' experiment at LCLS, it became clear that the conventional theory of synchrotron radiation cannot ensure the correct description of coherent and spontaneous emission from a kicked electron beam, nor the emission from a beam with finite angular divergence, in an undulator or a bending magnet. However, this result requires further experimental confirmation. In this publication we propose an uncomplicated and inexpensive experiment to test synchrotron radiation theory at 3rd generation light sources.

  9. Thermal Vacuum Test of Ice as a Phase Change Material Integrated with a Radiator

    Science.gov (United States)

    Lee, Steve A.; Leimkuehler, Thomas O.; Stephan, Ryan; Le, Hung V.

    2010-01-01

    Water may be used as radiation shielding for Solar Particle Events (SPE) to protect crewmembers in the Lunar Electric Rover (LER). Because the water is already present for radiation protection, it could also provide a mass efficient solution to the vehicle's thermal control system. This water can be frozen by heat rejection from a radiator and used as a Phase Change Material (PC1V1) for thermal storage. Use of this water as a PCM can eliminate the need for a pumped fluid loop thermal control system as well as reduce the required size of the radiator. This paper describes the testing and analysis performed for the Rover Engineering Development Unit (REDU), a scaled-down version of a water PCM heat sink for the LER. The REDU was tested in a thermal-vacuum chamber at environmental temperatures similar to those of a horizontal radiator panel on the lunar surface. Testing included complete freeze and melt cycles along with scaled transient heat load profiles simulating a 24-hour day for the rover.

  10. Man-made radionuclides in the environment and resulting radiation exposures

    International Nuclear Information System (INIS)

    Michel, R.

    2009-01-01

    This contribution gives a survey about the sources of man-made environmental radioactivity and quantifies some of the resulting radiation exposures. The relevance of the different radionuclides with respect to the radiation exposures is discussed. Finally, the question of the effects of small doses is addressed. (orig.)

  11. Testing and analysis of tube voltage and tube current in the radiation generator for mammography

    International Nuclear Information System (INIS)

    Jung, Hong Ryang; Hong, Dong Hee; Han, Beom Hui

    2014-01-01

    Breast shooting performance management and quality control of the generator is applied to the amount of current IEC(International Electrotechnical Commission) 60601-2-45 tube voltage and tube current are based on standards that were proposed in the analysis of the test results were as follows. Tube voltage according to the value of the standard deviation by year of manufacture from 2001 to 2010 as a 42-3.15 showed the most significant, according to the year of manufacture by tube amperage value of the standard deviation to 6.38 in the pre-2000 showed the most significant , manufactured after 2011 the standard deviation of the devices, the PAE(Percent Average Error) was relatively low. This latest generation device was manufactured in the breast of the tube voltage and tube diagnosed shooting the correct amount of current to maintain the performance that can be seen. The results of this study as the basis for radiography diagnosed breast caused by using the device's performance and maintain quality control, so the current Food and Drug Administration 'about the safety of diagnostic radiation generator rule' specified in the test cycle during three years of self-inspection radiation on a radiation generating device ensure safety and performance of the device using a coherent X-ray(constancy) by two ultimately able to keep the radiation dose to the public to reduce the expected effect is expected

  12. Initial Results from On-Orbit Testing of the Fram Memory Test Experiment on the Fastsat Micro-Satellite

    Science.gov (United States)

    MacLeond, Todd C.; Sims, W. Herb; Varnavas,Kosta A.; Ho, Fat D.

    2011-01-01

    The Memory Test Experiment is a space test of a ferroelectric memory device on a low Earth orbit satellite that launched in November 2010. The memory device being tested is a commercial Ramtron Inc. 512K memory device. The circuit was designed into the satellite avionics and is not used to control the satellite. The test consists of writing and reading data with the ferroelectric based memory device. Any errors are detected and are stored on board the satellite. The data is sent to the ground through telemetry once a day. Analysis of the data can determine the kind of error that was found and will lead to a better understanding of the effects of space radiation on memory systems. The test is one of the first flight demonstrations of ferroelectric memory in a near polar orbit which allows testing in a varied radiation environment. The initial data from the test is presented. This paper details the goals and purpose of this experiment as well as the development process. The process for analyzing the data to gain the maximum understanding of the performance of the ferroelectric memory device is detailed.

  13. Preliminary assays for lemongrass essential oil ecotoxicological test in D. similis and C. silvestrii submitted to gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Gimiliani, Giovana T.; Rogero, Sizue O.; Rogero, Jose R., E-mail: gtgimiliani@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Cruz, Aurea S. [Instituto Adolfo Lutz, Sao Paulo, SP (Brazil). Culturas Celulares

    2011-07-01

    Pharmaceutical products are of great interest in ecotoxicological studies due to being found some of these products in the superficial waters and sediments, water and sewage treatment effluents. It was verified an increase of insect repellent chemical products in the aquatic environment because of the increase of diseases transmitted by mosquitoes like dengue. As these compounds show toxicity, the use of essential oils natural products with repellent properties is increasing and the literature about the impact in the aquatic environment is scarce. The hydric frame would suffer natural radiation and radiations from energy generation nuclear plants impacts fall out of tests and nuclear accidents. There is no universal definition of environmental protection and there are few studies on radiation effects in the aquatic environment. In this study was determined the lemon grass essential oil toxicity level as well as the lethal dose of ionizing radiation, LD{sub 50}, in aquatic organisms. Cytotoxicity test was performed by in vitro neutral red uptake method in NCTC clone L929 cell line. In the LD{sub 50} test aquatic organisms were submitted to gamma radiation. The essential oil of lemongrass Cymbopogon flexuosus showed cytotoxicity index IC{sub 50} about 50{mu}g.mL{sup -1}. The LD{sub 50} for Daphnia similis was 242 Gy and Ceriodaphnia silvestrii about 525 Gy. Studies will be continued with acute and chronic ecotoxicological tests of lemongrass essential oil in natural organisms and in organisms submitted to gamma radiation, utilizing the results obtained in this work. (author)

  14. Development and testing of a thermoluminescent dosemeter for mixed neutron-photon-beta radiation fields

    International Nuclear Information System (INIS)

    Zummo, J.J.; Liu, J.C.

    1998-08-01

    A new four-element thermoluminescent (TL) dosemeter and dose evaluation algorithm have been developed and tested to better characterize personnel exposure in mixed neutron-photon-beta radiation fields. The prototype dosemeter is based on a commercially available TL card (with three LiF-7 chips and one LiF-6 chip) and modified filtration elements. The new algorithm takes advantage of the high temperature peak characteristics of the LiF-6 element to better quantify the neutron dose component. The dosemeter was tested in various radiation fields, consisting of mixtures of two radiation types typically used for dosemeter performance testing, as well as mixtures of three radiation types to simulate possible exposure conditions. The new dosemeter gave superior performance, based on the tolerance levels, when using the new algorithm as compared to a conventional algorithm that did not use the high temperature peak methodology. The limitations and further improvements are discussed

  15. Retinal, optic nerve and chiasmal function following radiation therapy demonstrated by visual evoked response testing

    International Nuclear Information System (INIS)

    Soni, A.B.; Constine, L.S.; Smith, D.; Palisca, M.; Ojomo, K.; Muhs, A.

    1997-01-01

    Purpose: To evaluate the tolerance of the retina, optic nerve, and optic chiasm to radiation doses conventionally used to treat patients with primary brain or pituitary tumors and to explore the character of detectable radiation effects. Visual evoked response (VER) testing is a noninvasive and sensitive method for identifying radiation injury to the visual system due to alterations in small vessel or myelin integrity. Such evaluations may increase our understanding of the threshold for and the pathogenesis of radiation injury. Materials and Methods: Twenty-four patients irradiated for brain or pituitary tumors between 1972 and 1996 had VER testing. Patients were included in study if the retina, optic nerves or chiasm were in the radiation (RT) field. At the time of RT patients ranged in age from 1.5 to 55 years (median 33). Mean doses were as follows: right retina, 29 Gy (range 10 - 60 Gy); left retina, 29.5 Gy (range 10 - 60 Gy); right optic nerve, 42.9 Gy (range 10 - 60 Gy); left optic nerve, 42.6 Gy (range 10 - 60 Gy); and optic chiasm, 48.2 Gy (range 10 - 65 Gy). Daily fractionation ranged from 1.5 to 1.8 Gy. Pattern VER testing distinguishes compressive or ischemic effects of tumor on the visual system from radiation retinopathy or optic neuropathy on the basis of the conduction amplitude and delay pattern. Prechiasm, chiasm, and postchiasm injuries are distinguishable by analyzing VER changes. Four evoked responses were obtained for each eye, each representing the average of 100 stimulus reversals. Results: VER was normal in 11 patients and abnormal in 13 patients. Only 2 patients (8%) had VER evidence of radiation injury to the visual system, one of whom had visual compromise. The other 11 abnormal patients had characteristic VER changes attributable to tumor or surgical damage. There was no significant difference in the radiation doses given to any subgroup. The one patient with radiation retinopathy had received 55-60 Gy to the posterior globe. Ten years

  16. Radiation exposure and health damage of residents at Semipalatinsk nuclear test site

    International Nuclear Information System (INIS)

    Tolebay, Rakhypbekov; Noso, Yoshihiro; Takechi, Nobuo

    2016-01-01

    Although the nuclear test site of Semipalatinsk (former Soviet Union and presently the Republic of Kazakhstan) stopped nuclear tests 25 years ago, there are presumably more than 200,000 victims near the site, including persons with a low dose and a high dose. Semey Medical University and Shimane University, together with the Kazakh Scientific Institute for Radiation Medicine and Ecology, have been conducting the measurement of radiation concentration of soil and the thyroid screening of residents. The following were surveyed: (1) chromosomal abnormality for 55 female residents (average 45 years in age) in heavily polluted areas and 25 female residents (average 42 years in age) in non-polluted areas, (2) mental abnormality of residents in polluted areas and non-polluted areas of Semey City, and (3) changes in the frequency of surgery cases for cancer between 1989 and 2014 at Semey Medical University Cancer Center. As for chromosomal abnormality, 3-5 times many mutation cases were observed in heavily polluted areas than in non-polluted areas. The nodules of thyroid gland were four times more frequent in heavily polluted areas. The frequency of a whole variety of cancers was nearly twice in polluted areas compared with in non-polluted areas, most of which were digestive system cancer, lung cancer, and breast cancer in the order. The frequency of mental abnormality has also increased nearly twice as compared to non-polluted areas, and it included neurological disorder, adjustment disorder, neuralgia, moderate depression, and learning disability. These results suggest that some physical effects can be caused by exposure. In the future, this study will investigate the effects of radiation exposure at the nuclear test site. (A.O.)

  17. Synchrotron radiation losses in Engineering Test Reactors (ETRs)

    International Nuclear Information System (INIS)

    Uckan, N.A.

    1987-11-01

    In next-generation Engineering Test Reactors (ETRs), one major objective is envisioned to be a long-pulse or steady-state burn using noninductive current drive. At the high temperatures needed for efficient current drive, synchrotron radiation could represent a large power loss, especially if wall reflectivity (R) is very low. Many INTOR-class ETR designs [Fusion Engineering Reactor (FER), Next European Torus (NET), OTR, Tokamak Ignition/Burn Engineering Reactor (TIBER), etc.] call for carbon-covered surfaces for which wall reflectivity is uncertain. Global radiation losses are estimated for these devices using empirical expressions given by Trubnikov (and others). Various operating scenarios are evaluated under the assumption that the plasma performance is limited by either the density limit (typical of the ignition phase) or the beta limit (typical of the current drive phase). For a case with ≥90% wall reflectivity, synchrotron radiation is not a significant contribution to the overall energy balance (the ratio of synchrotron to alpha power is less than 10 to 20%, even at ∼ 30 keV) and thus should not adversely alter performance in these devices. In extreme cases with 0% wall reflectivity, the ratio of synchrotron radiation to alpha power may approach 30 to 60% (depending on the device and limiting operating scenario), adversely affecting the performance characteristics. 12 refs., 7 tabs

  18. Radiative cooling test facility and performance evaluation of 4-MIL aluminized polyvinyl fluoride and white-paint surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Kruskopf, M.S.; Berdahl, P.; Martin, M.; Sakkal, F.; Sobolewski, M.

    1980-11-01

    A test facility designed to measure the amount of radiative cooling a specific material or assembly of materials will produce when exposed to the sky is described. Emphasis is placed upon assemblies which are specifically designed to produce radiative cooling and which therefore offer promise for the reduction of temperatures and/or humidities in occupied spaces. The hardware and software used to operate the facility are documented and the results of the first comprehensive experiments are presented. A microcomputer-based control/data acquisition system was employed to study the performance of two prototype radiator surfaces: 4-mil aluminized polyvinyl fluoride (PVF) and white painted surfaces set below polyethylene windscreens. The cooling rates for materials tested were determined and can be approximated by an equation (given). A computer model developed to simulate the cooling process is presented. (MCW)

  19. Verification test for radiation reduction effect and material integrity on PWR primary system by zinc injection

    Energy Technology Data Exchange (ETDEWEB)

    Kawakami, H.; Nagata, T.; Yamada, M. [Nuclear Power Engineering Corp. (Japan); Kasahara, K.; Tsuruta, T.; Nishimura, T. [Mitsubishi Heavy Industries, Ltd. (Japan); Ishigure, K. [Saitama Inst. of Tech. (Japan)

    2002-07-01

    Zinc injection is known to be an effective method for the reduction of radiation source in the primary water system of a PWR. There is a need to verify the effect of Zn injection operation on radiation source reduction and materials integrity of PWR primary circuit. In order to confirm the effectiveness of Zn injection, verification test as a national program sponsored by Ministry of Economy, Trade and Industry (METI) was started in 1995 for 7-year program, and will be finished by the end of March in 2002. This program consists of irradiation test and material integrity test. Irradiation test as an In-Pile-Test managed by AEAT Plc(UK) was performed using the LVR-15 reactor of NRI Rez in Check Republic. Furthermore, Out-of-Pile-Test using film adding unit was also performed to obtain supplemental data for In-Pile-Test at Takasago Engineering Laboratory of NUPEC. Material Integrity test was planned to perform constant load test, constant strain test and corrosion test at the same time using large scale Loop and slow strain extension rate testing (SSRT) at Takasago Engineering Laboratory of NUPEC. In this paper, the results of the verification test for Zinc program at present are discussed. (authors)

  20. Comparison of measured and calculated radiation doses in granite around emplacement holes in the spent-fuel test: Climax, Nevada Test Site

    International Nuclear Information System (INIS)

    van Konynenburg, R.A.

    1982-01-01

    Lawrence Livermore National Laboratory (LLNL) has emplaced eleven spent nuclear-reactor fuel assemblies in the Climax granite at the Nevada Test Site as part of the DOE Nevada Nuclear-Waste Storage Investigations. One of our objectives is to study radiation effects on the rock. The neutron and gamma-ray doses to the rock have been determined by MORSE-L Monte Carlo calculations and measurements using optical absorption and thermoluminescence dosimeters and metal foils. We compare the results to date. Generally, good agreement is found in the spatial and time dependence of the doses, but some of the absolute dose results appear to differ by more than the expected uncertainties. Although the agreement is judged to be adequate for radiation effects studies, suggestions for improving the precision of the calculations and measurements are made

  1. Measuring stations for gamma radiation - measured results 1982

    International Nuclear Information System (INIS)

    Kjelle, P.E.

    1983-01-01

    Gamma radiation is recorded continuously at 25 stations in Sweden. The evaluation of the data from five of the stations is made in a most accurate way, and the results are presented in this report. (G.B.)

  2. Results of calculations of external gamma radiation exposure rates from fallout and the related radionuclide compositions. Operation Tumbler-Snapper, 1952

    International Nuclear Information System (INIS)

    Hicks, H.G.

    1981-07-01

    This report presents data on calculated gamma radiation exposure rates and ground deposition of related radionuclides resulting from Events that deposited detectable radioactivity outside the Nevada Test Site complex

  3. Investigations of aircrews exposure to cosmic radiation - results, conclusions and suggestions

    CERN Document Server

    Bilski, P; Horwacik, T; Marczewska, B; Ochab, E; Olko, P

    2002-01-01

    In frame of a research project undertaken in collaboration with Polish airlines LOT, analysis of aircrews exposure to cosmic radiation has been performed. The applied methods included measurements of radiation doses with thermoluminescent detectors (MTS-N, MCP-N) and track detectors (CR-39) and also calculations of route doses with the CARI computer code. The obtained results indicate that aircrews of nearly all airplanes, with exception of these flying only on ATR aircraft, exceed regularly or may exceed in some conditions, effective doses of 1 mSv. In case of Boeing-767 aircrews such exceeding occurs always, independently of solar activity. Investigations revealed, that during these periods of the solar cycle, when intensity of cosmic radiation is high, exceeding of 6 mSv level is also possible. These results indicate, that according to Polish and European regulations it is necessary for airlines to provide regular estimations of radiation exposure of aircrews. Basing on the obtained results a system for pe...

  4. A Research Agenda for Radiation Oncology: Results of the Radiation Oncology Institute’s Comprehensive Research Needs Assessment

    International Nuclear Information System (INIS)

    Jagsi, Reshma; Bekelman, Justin E.; Brawley, Otis W.; Deasy, Joseph O.; Le, Quynh-Thu; Michalski, Jeff M.; Movsas, Benjamin; Thomas, Charles R.; Lawton, Colleen A.; Lawrence, Theodore S.; Hahn, Stephen M.

    2012-01-01

    Purpose: To promote the rational use of scarce research funding, scholars have developed methods for the systematic identification and prioritization of health research needs. The Radiation Oncology Institute commissioned an independent, comprehensive assessment of research needs for the advancement of radiation oncology care. Methods and Materials: The research needs assessment used a mixed-method, qualitative and quantitative social scientific approach, including structured interviews with diverse stakeholders, focus groups, surveys of American Society for Radiation Oncology (ASTRO) members, and a prioritization exercise using a modified Delphi technique. Results: Six co-equal priorities were identified: (1) Identify and develop communication strategies to help patients and others better understand radiation therapy; (2) Establish a set of quality indicators for major radiation oncology procedures and evaluate their use in radiation oncology delivery; (3) Identify best practices for the management of radiation toxicity and issues in cancer survivorship; (4) Conduct comparative effectiveness studies related to radiation therapy that consider clinical benefit, toxicity (including quality of life), and other outcomes; (5) Assess the value of radiation therapy; and (6) Develop a radiation oncology registry. Conclusions: To our knowledge, this prioritization exercise is the only comprehensive and methodologically rigorous assessment of research needs in the field of radiation oncology. Broad dissemination of these findings is critical to maximally leverage the impact of this work, particularly because grant funding decisions are often made by committees on which highly specialized disciplines such as radiation oncology are not well represented.

  5. Simulation and test of 3D silicon radiation detectors

    International Nuclear Information System (INIS)

    Fleta, C.; Pennicard, D.; Bates, R.; Parkes, C.; Pellegrini, G.; Lozano, M.; Wright, V.; Boscardin, M.; Dalla Betta, G.-F.; Piemonte, C.; Pozza, A.; Ronchin, S.; Zorzi, N.

    2007-01-01

    The work presented here is the result of the collaborative effort between the University of Glasgow, ITC-IRST (Trento) and IMB-CNM (Barcelona) in the framework of the CERN-RD50 Collaboration to produce 3D silicon radiation detectors and study their performance. This paper reports on two sets of 3D devices. IRST and CNM have fabricated a set of single-type column 3D detectors, which have columnar electrodes of the same doping type and an ohmic contact located at the backplane. Simulations of the device behaviour and electrical test results are presented. In particular, current-voltage, capacitance-voltage and charge collection efficiency measurements are reported. Other types of structures called double-sided 3D detectors are currently being fabricated at CNM. In these detectors the sets of n and p columns are made on opposite sides of the device. Electrical and technological simulations and first processing results are presented

  6. Use of micronucleus test in the assessment of radiation effects in aquatic environments

    International Nuclear Information System (INIS)

    Araujo, Edvaldo F. de; Silva, Luanna R.S.; Lima, Pedro A. de S.; Amancio, Francisco F.; Melo, Ana Maria M. de A.; Silva, Edvane B. da; Silva, Ronaldo C. da

    2011-01-01

    The study of the effects of radioactive substances on the environment is accomplished by radioecology. This science has played an important role in combating all forms of pollution. The uncontrolled use of physical and chemical agents has been a concern for environmental regulatory agencies, due to the serious damage to ecosystems. Aquatic organisms are exposed to a variety of pollutants harmful to aquatic systems. The mollusks Biomphalaria glabrata has been featured as a bioindicator to possess characteristics such as short reproductive cycle ease of maintenance in the laboratory and low maintenance cost. The micronucleus assay has been shown to be a great test to identify mutagenic effects caused by physical and chemical agents. In this study the frequency of micronuclei in haemocytes of Biomphalaria glabrata exposed to high doses of 60 Co gamma radiation contributing to a further standardization of this test as an indicator of the presence of radioactive contamination in aquatic environments. The young adult snails of Biomphalaria glabrata were divided into groups and subjected to a dose of 0 (control), 40 and 60 Gy of gamma radiation. The results showed that snails irradiated with 40 Gy showed a smaller number of haemocytes, whereas those exposed to 60 Gy had a greater quantity of these cells compared to control group. It can be concluded that the morphological analysis and the frequency of micronuclei in haemocytes of Biomphalaria glabrata exposed to 60 Co gamma radiation may be used in studies of the action of high doses of radiation in aquatic environments (author)

  7. Radiation Test Results on COTS and non-COTS Electronic Devices for NASA-JSC Space Flight Projects

    Science.gov (United States)

    Allums, Kimberly K.; O'Neill, P. M.; Reddell, B. D.; Nguyen, K. V.; Bailey, C. R.

    2012-01-01

    This presentation reports the results of recent proton and heavy ion Single Event Effect (SEE) testing on a variety of COTS and non-COTs electronic devices and assemblies tested for the Space Shuttle, International Space Station (ISS) and Multi-Purpose Crew Vehicle (MPCV).

  8. Aesthetic results following partial mastectomy and radiation therapy

    International Nuclear Information System (INIS)

    Matory, W.E. Jr.; Wertheimer, M.; Fitzgerald, T.J.; Walton, R.L.; Love, S.; Matory, W.E.

    1990-01-01

    This study was undertaken to determine the aesthetic changes inherent in partial mastectomy followed by radiation therapy in the treatment of stage I and stage II breast cancer. A retrospective analysis of breast cancer patients treated according to the National Surgical Adjuvant Breast Project Protocol B-06 was undertaken in 57 patients from 1984 to the present. The size of mastectomy varied between 2 x 1 cm and 15 x 8 cm. Objective aesthetic outcome, as determined by physical and photographic examination, was influenced primarily by surgical technique as opposed to the effects of radiation. These technical factors included orientation of resections, breast size relative to size of resection, location of tumor, and extent and orientation of axillary dissection. Regarding cosmesis, 80 percent of patients treated in this study judged their result to be excellent or good, in comparison to 50 percent excellent or good as judged by the plastic surgeon. Only 10 percent would consider mastectomy with reconstruction for contralateral disease. Asymmetry and contour abnormalities are far more common than noted in the radiation therapy literature. Patients satisfaction with lumpectomy and radiation, however, is very high. This satisfaction is not necessarily based on objective criteria defining aesthetic parameters, but is strongly influenced by retainment of the breast as an original body part

  9. Results from On-Orbit Testing of the Fram Memory Test Experiment on the Fastsat Micro-Satellite

    Science.gov (United States)

    MacLeod, Todd C.; Sims, W. Herb; Varnavas, Kosta A.; Ho, Fat D.

    2011-01-01

    NASA is planning on going beyond Low Earth orbit with manned exploration missions. The radiation environment for most Low Earth orbit missions is harsher than at the Earth's surface but much less harsh than deep space. Development of new electronics is needed to meet the requirements of high performance, radiation tolerance, and reliability. The need for both Volatile and Non-volatile memory has been identified. Emerging Non-volatile memory technologies (FRAM, C-RAM,M-RAM, R-RAM, Radiation Tolerant FLASH, SONOS, etc.) need to be investigated for use in Space missions. An opportunity arose to fly a small memory experiment on a high inclination satellite (FASTSAT). An off-the-shelf 512K Ramtron FRAM was chosen to be tested in the experiment.

  10. Accreditation and radiation protection - the cost or smaller doses and reliable results

    International Nuclear Information System (INIS)

    Omahen, G.; Zdesar, U.

    2011-01-01

    Laboratories involved in the protection against radiation and therefore in the measurement of radioactivity, dose rate and contamination have always been tied to the quality of their measurements, particularly those that have performed measurements for nuclear power plants. However in the laboratories more than quality it was more important, that people are professional, that they are engaged in scientific work and know how to interpret the results. Very often these are things that do not go along with reviewing the measuring instruments and quality records. However customer requires measurement results that can be trusted. This is the purpose of the standard SIST EN ISO / IEC 17025 in which the requirements for testing and calibration laboratories are standardised. The standard in force since 1999. In some countries, requests for accreditation of testing laboratories according to SIST EN ISO / IEC 17025 is even in regulation. This request is for example in the Croatian and Slovenian regulations for laboratories involved in measuring the radioactivity, dose rate, contamination, or by checking the X-ray apparatus. Several laboratories have been accreditation for several years. From that experience we can conclude that customer gets reliable results from the accredited laboratories at relatively low cost. On the other side laboratory which his accredited has introduced a line of work and his laboratory, there are rules for equipment, personnel, training and all that eventually enhanced measurement expertise. With accreditation, it is much easier to compensate for the loss of workers due to pension or leaving the laboratory because every moment must always be in the laboratory at least two who know how to work on the method. Accreditation is not improving radiation protection or reducing Becquerel in the air. But at least we know how accurate mSv or Bq are and how small mSv and Bq can be measured. (author) [sr

  11. Radiation resistance of polymer materials. Degradation evaluation by accelerated testing for application condition

    International Nuclear Information System (INIS)

    Seguchi, Tadao; Tamura, Kiyotoshi; Sorimachi, Masami

    2010-02-01

    This paper presents re-evaluated radiation resistance property data of polymer materials, which had been tested in past times in TAKASAKI Quantum Beam Science Directorate, for the future study of ageing evaluation of low voltage electric cable insulation materials used in light-water nuclear reactors. The radiation resistance of 25 types of plastics and rubbers materials applied in practical environments was evaluated by the accelerated testing of gamma-ray irradiation under oxygen pressure, and was compared with the radiation resistance determined from the traditional testing by irradiation with a high dose rate in air. The polymer materials were formulated to be similar or equivalent to practical materials, and the most of formulation (chemical compounds and quantities) were described. For all materials, the tensile properties (elongation at break, ultimate strength, 100% or 200% modulus), electric resistivity, gel-fraction, and density were measured after irradiation in oxidation conditions and irradiation in air with a high dose rate (non-oxidation conditions). The data of relations between each properties and total dose at various conditions were compiled, and the relations among the changes of mechanical properties, electrical properties, and radiation induced chemical reactions were discussed. (author)

  12. Non-destructive testing and radiation in industry

    International Nuclear Information System (INIS)

    Woodford, C; Ashby, P.

    2001-01-01

    Non-destructive testing (NDT) is a little known discipline which uses non-invasive and passive techniques to investigate the condition of materials and structures. Some of these techniques employ the use of radioisotopes. The penetrating radiations produced by these materials are applied in various ways to obtain the required information. This presentation is an overview of the application of radioisotopes within the scope of NDT. Notwithstanding the well established use of traditional materials, new forms of radioisotopes are being developed which will extend their capabilities

  13. Protective role of Tinospora cordifolia extract against radiation-induced qualitative, quantitative and biochemical alterations in testes

    International Nuclear Information System (INIS)

    Sharma, Priyanka; Parmar, Jyoti; Sharma, Priyanka; Verma, Preeti; Goyal, P.K.

    2012-01-01

    In today's changing global scenario, ionizing radiation is considered as most potent cause of oxidative stress mediated by free radical flux which induces severe damage at various hierarchical levels in the organization in the living organisms. Testis is a highly prolific tissue with fast cellular renewal and poor antioxidant defense; therefore it becomes an easy target for the radiation-induced free radicals that have long been suggested as major cause of male infertility. Chemical radioprotection is an important strategy to countermeasure the deleterious effects of radiation. Several Indian medicinal plants are rich source of antioxidants and these have been used for the treatment of ailments. Tinospora cordifolia, commonly known as amrita, is one of the plants that have several pharmacological and therapeutic properties. Therefore, the present study was performed to evaluate the deleterious effects of semi lethal dose of gamma radiation on testicular tissue and their possible inhibition by Tinospora cordifolia root extract (TCE). For this purpose, healthy Swiss albino male mice were selected from an inbred colony and divided into four groups. Group I (normal) was administered double distilled water (DDW) volume equal to TCE (75 mg/kg.b.wt/animal) by oral gavage. Group II was orally supplemented TCE as 75 mg/kg. b.wt once daily for 5 consecutive days. Group III (irradiated control) received DDW orally equivalent to TCE for 5 days then exposed to 5 Gy gamma radiation. Group IV (experimental) was administered TCE as in Group II and exposed to radiation (as in Group III). Irradiation resulted into significant decrease in the frequency of different spermatogenic cell counts along with severe histo-pathological lesions up to 7th day of irradiation in testes of irradiated control animals, thereafter, recovery followed towards the normal architecture. TCE pretreatment effectively prevented radiation induced such alterations in cellular counts and testicular injuries by

  14. Breast tomography with synchrotron radiation: preliminary results

    International Nuclear Information System (INIS)

    Pani, Silvia; Longo, Renata; Dreossi, Diego; Montanari, Francesco; Olivo, Alessandro; Arfelli, Fulvia; Bergamaschi, Anna; Poropat, Paolo; Rigon, Luigi; Zanconati, Fabrizio; Palma, Ludovico Dalla; Castelli, Edoardo

    2004-01-01

    A system for in vivo breast imaging with monochromatic x-rays has been designed and built at the synchrotron radiation facility Elettra in Trieste (Italy) and will be operational in 2004. The system design involves the possibility of performing both planar mammography and breast tomography. In the present work, the first results obtained with a test set-up for breast tomography are shown and discussed. Tomographic images of in vitro breasts were acquired using monochromatic x-ray beams in the energy range 20-28 keV and a linear array silicon pixel detector. Tomograms were reconstructed using standard filtered backprojection algorithms; the effect of different filters was evaluated. The attenuation coefficients of fibroglandular and adipose tissue were measured, and a quantitative comparison of images acquired at different energies was performed by calculating the differential signal-to-noise ratio of fibroglandular details in adipose tissue. All images required a dose comparable to the dose delivered in clinical, conventional mammography and showed a high resolution of the breast structures without the overlapping effects that limit the visibility of the structures in 2D mammography. A quantitative evaluation of the images proves that the image quality at a given dose increases in the considered energy range and for the considered breast sizes

  15. Results of cytogenetic surveillance of rural populations adjoining to Semipalatinsk test site

    International Nuclear Information System (INIS)

    Abdil'dinova, G.Zh.; Kundakbaeva, G.B.; Zhunusova, A.B.

    1997-01-01

    Purpose of the work is study of somatic cytogenetic effects with taking into consideration chromosomal aberration of population from Beskaragaj district of Semipalatinsk region exposed to influence of conducted nuclear tests on Semipalatinsk test site. Cultures of lymphocyates of peripheral flood were studied. Control group made up 15 man living in Akmola region locating out of radiation contaminated zone. It is determined, that common frequency of chromosomal aberration make up 3.6 on 100 cells. At that frequency of pair fragments made up 2.0 on 100 metaphases (0.2 in control group); dicentrics and center rings were revealed with summary frequency 0.6 on 100 metaphases and that is approximately in 15 fold greater than control index - 0.03 on 100 cells. Stable radiation markers (translocations, deletions) revealed with frequency 1.07 on 100 cells (control make up 0.4 on 100 cells). By results of of conducted cytogenetic analysis the attempt of mean group effective equivalent dose reconstruction received with inhabitants of Beskaragaj district is undertaken. It was calculated, that population of researched district have been got dose loading in 9.09 rem

  16. The effects of ultraviolet radiation on the planktonic community of a shallow, eutrophic estuary: results of mesocosm experiments

    NARCIS (Netherlands)

    Forster, R.M.; Schubert, H.

    2001-01-01

    This paper describes the results of pelagic mesocosm experiments designed to test the effects of enhanced and reduced ultraviolet radiation (UV) on the planktonic community of a Baltic Sea estuary. The Darss-Zingst estuary consists of a series of brackish lagoons with high concentrations of

  17. The script concordance test in radiation oncology: validation study of a new tool to assess clinical reasoning

    International Nuclear Information System (INIS)

    Lambert, Carole; Gagnon, Robert; Nguyen, David; Charlin, Bernard

    2009-01-01

    The Script Concordance test (SCT) is a reliable and valid tool to evaluate clinical reasoning in complex situations where experts' opinions may be divided. Scores reflect the degree of concordance between the performance of examinees and that of a reference panel of experienced physicians. The purpose of this study is to demonstrate SCT's usefulness in radiation oncology. A 90 items radiation oncology SCT was administered to 155 participants. Three levels of experience were tested: medical students (n = 70), radiation oncology residents (n = 38) and radiation oncologists (n = 47). Statistical tests were performed to assess reliability and to document validity. After item optimization, the test comprised 30 cases and 70 questions. Cronbach alpha was 0.90. Mean scores were 51.62 (± 8.19) for students, 71.20 (± 9.45) for residents and 76.67 (± 6.14) for radiation oncologists. The difference between the three groups was statistically significant when compared by the Kruskall-Wallis test (p < 0.001). The SCT is reliable and useful to discriminate among participants according to their level of experience in radiation oncology. It appears as a useful tool to document the progression of reasoning during residency training

  18. Prone Breast Intensity Modulated Radiation Therapy: 5-Year Results

    International Nuclear Information System (INIS)

    Osa, Etin-Osa O.; DeWyngaert, Keith; Roses, Daniel; Speyer, James; Guth, Amber; Axelrod, Deborah; Fenton Kerimian, Maria; Goldberg, Judith D.; Formenti, Silvia C.

    2014-01-01

    Purpose: To report the 5-year results of a technique of prone breast radiation therapy delivered by a regimen of accelerated intensity modulated radiation therapy with a concurrent boost to the tumor bed. Methods and Materials: Between 2003 and 2006, 404 patients with stage I-II breast cancer were prospectively enrolled into 2 consecutive protocols, institutional trials 03-30 and 05-181, that used the same regimen of 40.5 Gy/15 fractions delivered to the index breast over 3 weeks, with a concomitant daily boost to the tumor bed of 0.5 Gy (total dose 48 Gy). All patients were treated after segmental mastectomy and had negative margins and nodal assessment. Patients were set up prone: only if lung or heart volumes were in the field was a supine setup attempted and chosen if found to better spare these organs. Results: Ninety-two percent of patients were treated prone, 8% supine. Seventy-two percent had stage I, 28% stage II invasive breast cancer. In-field lung volume ranged from 0 to 228.27 cm 3 , mean 19.65 cm 3 . In-field heart volume for left breast cancer patients ranged from 0 to 21.24 cm 3 , mean 1.59 cm 3 . There was no heart in the field for right breast cancer patients. At a median follow-up of 5 years, the 5-year cumulative incidence of isolated ipsilateral breast tumor recurrence was 0.82% (95% confidence interval [CI] 0.65%-1.04%). The 5-year cumulative incidence of regional recurrence was 0.53% (95% CI 0.41%-0.69%), and the 5-year overall cumulative death rate was 1.28% (95% CI 0.48%-3.38%). Eighty-two percent (95% CI 77%-85%) of patients judged their final cosmetic result as excellent/good. Conclusions: Prone accelerated intensity modulated radiation therapy with a concomitant boost results in excellent local control and optimal sparing of heart and lung, with good cosmesis. Radiation Therapy Oncology Group protocol 1005, a phase 3, multi-institutional, randomized trial is ongoing and is evaluating the equivalence of a similar dose and fractionation

  19. Prone Breast Intensity Modulated Radiation Therapy: 5-Year Results

    Energy Technology Data Exchange (ETDEWEB)

    Osa, Etin-Osa O.; DeWyngaert, Keith [Department of Radiation Oncology, New York University School of Medicine, New York, New York (United States); Roses, Daniel [Department of Surgery, New York University School of Medicine, New York, New York (United States); Speyer, James [Department of Medical Oncology, New York University School of Medicine, New York, New York (United States); Guth, Amber; Axelrod, Deborah [Department of Surgery, New York University School of Medicine, New York, New York (United States); Fenton Kerimian, Maria [Department of Radiation Oncology, New York University School of Medicine, New York, New York (United States); Goldberg, Judith D. [Department of Population Health, New York University School of Medicine, New York, New York (United States); Formenti, Silvia C., E-mail: Silvia.formenti@nyumc.org [Department of Radiation Oncology, New York University School of Medicine, New York, New York (United States)

    2014-07-15

    Purpose: To report the 5-year results of a technique of prone breast radiation therapy delivered by a regimen of accelerated intensity modulated radiation therapy with a concurrent boost to the tumor bed. Methods and Materials: Between 2003 and 2006, 404 patients with stage I-II breast cancer were prospectively enrolled into 2 consecutive protocols, institutional trials 03-30 and 05-181, that used the same regimen of 40.5 Gy/15 fractions delivered to the index breast over 3 weeks, with a concomitant daily boost to the tumor bed of 0.5 Gy (total dose 48 Gy). All patients were treated after segmental mastectomy and had negative margins and nodal assessment. Patients were set up prone: only if lung or heart volumes were in the field was a supine setup attempted and chosen if found to better spare these organs. Results: Ninety-two percent of patients were treated prone, 8% supine. Seventy-two percent had stage I, 28% stage II invasive breast cancer. In-field lung volume ranged from 0 to 228.27 cm{sup 3}, mean 19.65 cm{sup 3}. In-field heart volume for left breast cancer patients ranged from 0 to 21.24 cm{sup 3}, mean 1.59 cm{sup 3}. There was no heart in the field for right breast cancer patients. At a median follow-up of 5 years, the 5-year cumulative incidence of isolated ipsilateral breast tumor recurrence was 0.82% (95% confidence interval [CI] 0.65%-1.04%). The 5-year cumulative incidence of regional recurrence was 0.53% (95% CI 0.41%-0.69%), and the 5-year overall cumulative death rate was 1.28% (95% CI 0.48%-3.38%). Eighty-two percent (95% CI 77%-85%) of patients judged their final cosmetic result as excellent/good. Conclusions: Prone accelerated intensity modulated radiation therapy with a concomitant boost results in excellent local control and optimal sparing of heart and lung, with good cosmesis. Radiation Therapy Oncology Group protocol 1005, a phase 3, multi-institutional, randomized trial is ongoing and is evaluating the equivalence of a similar dose and

  20. Epidemiological and immunological studies of radiation accidents and nucleare tests participants

    International Nuclear Information System (INIS)

    Shubik, V. M.; Bronstein, I. E.; Koroleva, T.M.; Strelnicova, T.M.; Sukalskay, S. J.

    2004-01-01

    Results of long term studies of epidemiological and immunological problems after radiation accidents in Ural. At Chernobyl and nuclear weapons tests in Semi-palatinsk and Novaya Zemlya nuclear tests sites are presented. Changes in Health and immunity status of emergency team workers (liquida-tors) and participants on nuclear weapon tests were recorded in long term studies af-ter 10 and more years after radiation exposure. Some changes (decrease in ly-sozyme activity, disimmunoglobulinemia) could be attributed to the old age of exam-ined persons and concomitant cardiovasculatory, respiratory and other diseases An-other ones were related to the autoimmune syndromes. Humoral and cellular auto-immune changes were more pronounced in liquidators and participants then in controls. concentrations of antitissue antibodies in exposed cohort was three times higher than in control. Level of antibodies to thyroid antigens (microsoms and thy-roglobulines) were five times higher in liquidators of Chernobyl accident. The pos-sible role of humoral and cell autoimmune changes in the development of cardiovascular, liver, kidney and thyroid is considered. Considerable increase in some cytocine concentrations in blood of participants was found. For example increased concentration of TNF was recorded in half of par-ticipants from Novaya Zemlya in comparison to similar changes in only twenty pro-cents of controls. In half of participants from Semipalatinsk site the virus antigens in epithelium of higher respiratory tract (mostly adenoviruses) were found, with 22% in control group. In health and immunity studies of population from the contaminated areas after accidents and nuclear tests (Ural, Bryansk, Russian arktics) the demographics changes, mortality structure changes, oncological mortality and immunological deficiencies were found. The recorded effects might by considered as a results of combined effect of ra-diological and non-radiological factors. The potentiated effect of chronic

  1. Pathogenesis of acute radiation effects in the urinary bladder. Experimental results

    International Nuclear Information System (INIS)

    Doerr, W.; Eckhardt, M.; Ehme, A.; Koi, S.

    1998-01-01

    Purpose: The present review summarizes experimental studies of the pathogenesis of acute radiation-induced changes in urinary bladder function. Material and methods: Transurethral cystometry was used for longitudinal assessment of bladder function in mice. With this technique, radiation-induced changes in storage capacity can be quantified. In histological studies, changes in urothelial cell density and in urothelial protein expression during the acute radiation response were determined. Acetylsalicylic acid (ASA) was used for the treatment of acute functional changes. Results: The histological studies did not reveal any systematic fluctuations in urothelial cell density during the time of the acute radiation response. However, characteristic changes in the expression of proteins associated with urothelial cell function, differentiation and cell contact were observed, which correlated with the functional impairment. By local or systemical application of ASA, a significant restoration of bladder function compared to placebo treatment could be achieved. Conclusion: Acute functional radiation effects in the urinary bladder are not based on urothelial denudation. However, changes in protein expression indicate an impairment of the urothelial barrier function. The results of ASA treatment demonstrate that prostaglandins are involved in the response. Alterations in urothelial or endothelial prostaglandin metabolism may be primarily radiation-induced or secondary because of the impaired urothelial barrier. (orig.) [de

  2. Assessment of radiation risks as a result of the Chernobyl accident

    International Nuclear Information System (INIS)

    Ivanov, V.K.

    1998-01-01

    Full text of publication follows: the Government of the former USSR had made decision on establishing common registry of exposed persons in several months after the Chernobyl accident. The registry had served in Medical Radiological Research Centre of Russian Academy of Medical Sciences, Obninsk City till 1992 (the time of dissolution of the USSR). Individual medical and dosimetric information on 659292 persons, including 284907 emergency accident workers (liquidators) had been collected for the period between 1986 and 1991. As of 01.01.1998, National Chernobyl Registry of the Russian Federation has kept individual data on 508236 persons including 167726 liquidators. As it is known, long-term epidemiological study of Hiroshima and Nagasaki A-bomb survivors resulted in statistically significant assessments of radiation risks for induction of cancer at the dose level above 0.5 Gy. Radiation doses after the Chernobyl accident do not exceed 0.3-0.5 Gy. That is why assessment of radiation risks at low radiation doses is a problem of great importance. As a result of the epidemiological studies performed on the basis of the Russian Chernobyl registry we pioneered the assessment of statistically significant radiation risks for induction of cancer at low radiation dose. (author)

  3. Radiation therapy in old patients. Side effects and results of radiation therapy in old patients

    International Nuclear Information System (INIS)

    Geinitz, H.; Zimmermann, F.B.; Molls, M.

    1999-01-01

    Background: Despite a growing number of elderly patients receiving radiation therapy little is known about side effects and outcome of irradiation in this section of the population. Methods: In a review article epidemiologic data, aspects of radiation-biology as well as side effects and outcome of radiation therapy of elderly patients are discussed. Results: Cancer incidence rises with age and is exceeding 3.5% for males older than 85 years. With a life expectancy of more than 4 years, curative therapy is indicated even at this age. Furthermore, several retrospective studies indicate that local control and disease-Specific survival after radiation therapy of elderly patients is comparable with that of younger persons. The exception contains elderly patients with grade-III to IV gliomas or with rectal carcinoma who show a reduced survival which is perhaps caused by less aggressive combined treatment (tumor resection). Although some biological and molecular data indicate a rise in radiation sensitivity with growing age like the reduction of the capacity of some DNA-repair enzymes, there is no convincing evidence in animal studies or in retrospective clinical studies that radiation therapy is generally less well tolerated by older individuals. Some age-depending differences in organ toxicities are described in 3 large studies, which evaluate the data of patients who were enrolled in different EORTC-trials: Older patients suffer more of functional mucositis in case of radiation therapy to the head and neck, they have an increased weight loss and a higher frequency of late esophageal damage when irradiated in the thorax, and they show a higher prevalence of sexual dysfunction when treated with radiation therapy to the pelvis. On the other hand younger patients suffer more from acute toxicity like skin damage, nausea, and deterioration of the performance status during pelvic radiotherapy. When discussing the dose intensity of radiation therapy concomitant disease which

  4. Using the FLUKA Monte Carlo Code to Simulate the Interactions of Ionizing Radiation with Matter to Assist and Aid Our Understanding of Ground Based Accelerator Testing, Space Hardware Design, and Secondary Space Radiation Environments

    Science.gov (United States)

    Reddell, Brandon

    2015-01-01

    Designing hardware to operate in the space radiation environment is a very difficult and costly activity. Ground based particle accelerators can be used to test for exposure to the radiation environment, one species at a time, however, the actual space environment cannot be duplicated because of the range of energies and isotropic nature of space radiation. The FLUKA Monte Carlo code is an integrated physics package based at CERN that has been under development for the last 40+ years and includes the most up-to-date fundamental physics theory and particle physics data. This work presents an overview of FLUKA and how it has been used in conjunction with ground based radiation testing for NASA and improve our understanding of secondary particle environments resulting from the interaction of space radiation with matter.

  5. Offsite environmental monitoring report. Radiation monitoring around United States nuclear test areas, calendar year 1997

    International Nuclear Information System (INIS)

    Davis, M.G.; Flotard, R.D.; Fontana, C.A.; Hennessey, P.A.; Maunu, H.K.; Mouck, T.L.; Mullen, A.A.; Sells, M.D.

    1999-01-01

    This report describes the Offsite Radiological Environmental Monitoring Program (OREMP) conducted during 1997 by the US Environmental Protection Agency's (EPAs), Radiation and Indoor Environments National Laboratory, Las Vegas, Nevada. This laboratory operated an environmental radiation monitoring program in the region surrounding the Nevada Test Site (NTS) and at former test sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The surveillance program is designed to measure levels and trends of radioactivity, if present, in the environment surrounding testing areas to ascertain whether current radiation levels and associated doses to the general public are in compliance with existing radiation protection standards. The surveillance program additionally has the responsibility to take action to protect the health and well being of the public in the event of any accidental release of radioactive contaminants. Offsite levels of radiation and radioactivity are assessed by sampling and analyzing milk, water, and air; by deploying and reading thermoluminescent dosimeters (TLDs); and using pressurized ionization chambers (PICs) to measure ambient gamma exposure rates with a sensitivity capable of detecting low level exposures not detected by other monitoring methods

  6. Offsite environmental monitoring report: Radiation monitoring around United States nuclear test areas, calendar year 1997

    Energy Technology Data Exchange (ETDEWEB)

    Davis, M.G.; Flotard, R.D.; Fontana, C.A.; Hennessey, P.A.; Maunu, H.K.; Mouck, T.L.; Mullen, A.A.; Sells, M.D.

    1999-01-01

    This report describes the Offsite Radiological Environmental Monitoring Program (OREMP) conducted during 1997 by the US Environmental Protection Agency`s (EPAs), Radiation and Indoor Environments National Laboratory, Las Vegas, Nevada. This laboratory operated an environmental radiation monitoring program in the region surrounding the Nevada Test Site (NTS) and at former test sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The surveillance program is designed to measure levels and trends of radioactivity, if present, in the environment surrounding testing areas to ascertain whether current radiation levels and associated doses to the general public are in compliance with existing radiation protection standards. The surveillance program additionally has the responsibility to take action to protect the health and well being of the public in the event of any accidental release of radioactive contaminants. Offsite levels of radiation and radioactivity are assessed by sampling and analyzing milk, water, and air; by deploying and reading thermoluminescent dosimeters (TLDs); and using pressurized ionization chambers (PICs) to measure ambient gamma exposure rates with a sensitivity capable of detecting low level exposures not detected by other monitoring methods.

  7. Offsite environmental monitoring report: Radiation monitoring around United States nuclear test areas, calendar year 1993

    International Nuclear Information System (INIS)

    Chaloud, D.J; Daigler, D.M.; Davis, M.G.

    1996-06-01

    This report describes the Offsite Radiation Safety Program conducted during 1993 by the Environmental Protection Agency's (EPA's) Environmental Monitoring Systems Laboratory - Las Vegas (EMSL-LV). This laboratory operates an environmental radiation monitoring program in the region surrounding the Nevada Test Site (NTS) and at former test sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The surveillance program is designed to measure levels and trends of radioactivity, if present, in the environment surrounding testing areas to ascertain whether current radiation levels and associated doses to the general public are in compliance with existing radiation protection standards. The surveillance program additionally has the responsibility to take action to protect the health and well being of the public in the event of any accidental release of radioactive contaminants. Offsite levels of radiation and radioactivity are assessed by sampling milk, water, and air; by deploying thermoluminescent dosimeters (TLDs) and using pressurized ionization chambers (PICs); by biological monitoring of foodstuffs including animal tissues and food crops; and by measurement of radioactive material deposited in humans

  8. Offsite environmental monitoring report: Radiation monitoring around United States nuclear test areas, calendar year 1993

    Energy Technology Data Exchange (ETDEWEB)

    Chaloud, D.J; Daigler, D.M.; Davis, M.G. [and others

    1996-06-01

    This report describes the Offsite Radiation Safety Program conducted during 1993 by the Environmental Protection Agency`s (EPA`s) Environmental Monitoring Systems Laboratory - Las Vegas (EMSL-LV). This laboratory operates an environmental radiation monitoring program in the region surrounding the Nevada Test Site (NTS) and at former test sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The surveillance program is designed to measure levels and trends of radioactivity, if present, in the environment surrounding testing areas to ascertain whether current radiation levels and associated doses to the general public are in compliance with existing radiation protection standards. The surveillance program additionally has the responsibility to take action to protect the health and well being of the public in the event of any accidental release of radioactive contaminants. Offsite levels of radiation and radioactivity are assessed by sampling milk, water, and air; by deploying thermoluminescent dosimeters (TLDs) and using pressurized ionization chambers (PICs); by biological monitoring of foodstuffs including animal tissues and food crops; and by measurement of radioactive material deposited in humans.

  9. Radiation damage at LHCb, results and expectations

    CERN Multimedia

    Faerber, Christian

    2011-01-01

    The LHCb Detector is a single-arm spectrometer at the LHC designed to detect new physics through measuring CP violation and rare decays of heavy flavor mesons. The detector consists of vertex detector, tracking system, dipole magnet, 2 RICH detectors, em. calorimeter, hadron calorimeter, muon detector which all use different technologies and suffer differently from radiation damage. These radiation damage results and the investigation methods will be shown. The delivered luminosity till July 2011 was about 450 pb−1. The Vertex detector receives the highest particle flux at LHCb. The currents drawn by the silicon sensors are, as expected, increasing proportional to the integrated luminosity. The highest irradiaton regions of the n-bulk silicon sensors are observed to have recently undergone space charge sign inversion. The Silicon Trackers show increasing leakage currents comparable with earlier predictions. The electromagentic calorimeter and hadron calorimeter suffer under percent-level signal decrease whi...

  10. What one should know about radiation. Comparison of radiation burden from the Chernobyl accident and the atomic weapons test

    Energy Technology Data Exchange (ETDEWEB)

    Burtscher, A

    1986-01-01

    The natural radiation burden, that due to the Chernobyl accident and the atmospheric nuclear weapons tests in Austria are compared. The overall Chernobyl burden is estimated at 50-70% of the annual natural burden and thus less than the burden from atmospheric nuclear weapons tests. (G.Q.).

  11. Latch-up and radiation integrated circuit--LURIC: a test chip for CMOS latch-up investigation

    International Nuclear Information System (INIS)

    Estreich, D.B.

    1978-11-01

    A CMOS integrated circuit test chip (Latch-Up and Radiation Integrated Circuit--LURIC) designed for CMOS latch-up and radiation effects research is described. The purpose of LURIC is (a) to provide information on the physics of CMOS latch-up, (b) to study the layout dependence of CMOS latch-up, and (c) to provide special latch-up test structures for the development and verification of a latch-up model. Many devices and test patterns on LURIC are also well suited for radiation effects studies. LURIC contains 86 devices and related test structures. A 12-layer mask set allows both metal gate CMOS and silicon gate ELA (Extended Linear Array) CMOS to be fabricated. Six categories of test devices and related test structures are included. These are (a) the CD4007 metal gate CMOS IC with auxiliary test structures, (b) ELA CMOS cells, (c) field-aided lateral pnp transistors, (d) p-well and substrate spreading resistance test structures, (e) latch-up test structures (simplified symmetrical latch-up paths), and (f) support test patterns (e.g., MOS capacitors, p + n diodes, MOS test transistors, van der Pauw and Kelvin contact resistance test patterns, etc.). A standard probe pattern array has been used on all twenty-four subchips for testing convenience

  12. The Xenon Test Chamber Q-SUN® for testing realistic tolerances of fungi exposed to simulated full spectrum solar radiation.

    Science.gov (United States)

    Dias, Luciana P; Araújo, Claudinéia A S; Pupin, Breno; Ferreira, Paulo C; Braga, Gilberto Ú L; Rangel, Drauzio E N

    2018-06-01

    The low survival of insect-pathogenic fungi when used for insect control in agriculture is mainly due to the deleterious effects of ultraviolet radiation and heat from solar irradiation. In this study, conidia of 15 species of entomopathogenic fungi were exposed to simulated full-spectrum solar radiation emitted by a Xenon Test Chamber Q-SUN XE-3-HC 340S (Q-LAB ® Corporation, Westlake, OH, USA), which very closely simulates full-spectrum solar radiation. A dendrogram obtained from cluster analyses, based on lethal time 50 % and 90 % calculated by Probit analyses, separated the fungi into three clusters: cluster 3 contains species with highest tolerance to simulated full-spectrum solar radiation, included Metarhizium acridum, Cladosporium herbarum, and Trichothecium roseum with LT 50  > 200 min irradiation. Cluster 2 contains eight species with moderate UV tolerance: Aschersonia aleyrodis, Isaria fumosorosea, Mariannaea pruinosa, Metarhizium anisopliae, Metarhizium brunneum, Metarhizium robertsii, Simplicillium lanosoniveum, and Torrubiella homopterorum with LT 50 between 120 and 150 min irradiation. The four species in cluster 1 had the lowest UV tolerance: Lecanicillium aphanocladii, Beauveria bassiana, Tolypocladium cylindrosporum, and Tolypocladium inflatum with LT 50  solar radiation before. We conclude that the equipment provided an excellent tool for testing realistic tolerances of fungi to full-spectrum solar radiation of microbial agents for insect biological control in agriculture. Copyright © 2018 British Mycological Society. Published by Elsevier Ltd. All rights reserved.

  13. Testing the radiation hardness of lead tungstate scintillating crystals

    CERN Document Server

    Shao, M; Li Chuan; Chen, H; Xu, Z Z; Wang, Z M

    2000-01-01

    Large Hadron Collider operation will produce a high radiation background. PbWO/sub 4/ crystals are selected as scintillators for the CMS electromagnetic calorimeter. To reach the precise requirement for energy measurements, a strict requirement for the radiation hardness is needed. In this paper, we present a method for evaluating the radiation hardness and its measurement. Results for several full size (23 cm length) lead tungstate crystals under Co/sup 60/ gamma - ray irradiation are given, investigating the light yield loss and its longitudinal uniformity. (8 refs).

  14. The relationship of thyroid cancer with radiation exposure from nuclear weapon testing in the Marshall Islands.

    Science.gov (United States)

    Takahashi, Tatsuya; Schoemaker, Minouk J; Trott, Klaus R; Simon, Steven L; Fujimori, Keisei; Nakashima, Noriaki; Fukao, Akira; Saito, Hiroshi

    2003-03-01

    The US nuclear weapons testing program in the Pacific conducted between 1946 and 1958 resulted in radiation exposure in the Marshall Islands. The potentially widespread radiation exposure from radio-iodines of fallout has raised concerns about the risk of thyroid cancer in the Marshallese population. The most serious exposures and its health hazards resulted from the hydrogen-thermonuclear bomb test, the Castle BRAVO, on March 1, 1954. Between 1993 and 1997, we screened 3,709 Marshallese for thyroid disease who were born before the BRAVO test. It was 60% of the entire population at risk and who were still alive at the time of our examinations. We diagnosed 30 thyroid cancers and found 27 other study participants who had been operated for thyroid cancer before our screening in this group. Fifty-seven Marshallese born before 1954 (1.5%) had thyroid cancer or had been operated for thyroid cancer. Nearly all (92%) of these cancers were papillary carcinoma. We derived estimates of individual thyroid dose proxy from the BRAVO test in 1954 on the basis of published age-specific doses estimated on Utirik atoll and 137Cs deposition levels on the atolls where the participants came from. There was suggestive evidence that the prevalence of thyroid cancer increased with category of estimated dose to the thyroid.

  15. The relationship of thyroid cancer with radiation exposure from nuclear weapon testing in the Marshall Islands

    International Nuclear Information System (INIS)

    Takahashi, Tatsuya; Fukao, Akira; Trott, K.R.; Simon, S.L.; Fujimori, Keisei; Nakashima, Noriaki; Saito, Hiroshi

    2003-01-01

    The US nuclear weapons testing program in the Pacific conducted between 1946 and 1958 resulted in radiation exposure in the Marshall Islands. The potentially widespread radiation exposure from radioiodines of fallout has raised concerns about the risk of thyroid cancer in the Marshallese population. The most serious exposures and its health hazards resulted from the hydrogen-thermonuclear bomb test, the Castle BRAVO, on March 1, 1954. Between 1993 and 1997, we screened 3,709 Marshallese for thyroid disease who were born before the BRAVO test. It was 60% of the entire population at risk and who were still alive at the time of our examinations. We diagnosed 30 thyroid cancers and found 27 other study participants who had been operated for thyroid cancer before our screening in this group. Fifty-seven Marshallese born before 1954 (1.5%) had thyroid cancer or had been operated for thyroid cancer. Nearly all (92%) of these cancers were papillary carcinoma. We derived estimates of individual thyroid dose proxy from the BRAVO test in 1954 on the basis of published age-specific doses estimated on Utirik atoll and 137 Cs deposition levels on the atolls where the participants came from. There was suggestive evidence that the prevalence of thyroid cancer increased with category of estimated dose to the thyroid. (author)

  16. Test models for estimating radiation balance in different scales for Jaboticabal, SP

    Directory of Open Access Journals (Sweden)

    Valquíria de Alencar Beserra

    2012-12-01

    Full Text Available The net radiation (Rn in agroecosystems is the amount of energy that is available in the environment to heating processes of living organisms, air and soil; perspiration of animals and plants; photosynthesis and water evaporation. The Rn defines the type of climate and weather conditions prevailing in a region affecting the availability and thermal water, the fundamental understanding of genotype-environment, which ultimately determine the productivity of the agricultural system. Rn usually is used in models of weather and climate studies. The sustainability and economic viability of zootechnical activity is dependent on the positive interaction between animal and environment. Environmental factors such as water, shading, thermal exchanges sensible heat (conduction, convection and radiation skin and latent heat losses (evaporation and transpiration, conditioned by Rn, must be managed to provide the best results. The present study was conducted to develop and test models for accurate and precise radiation balance on the scales daily, monthly and seasonal ten-day for Jaboticabal - SP, due to the importance of estimates of net radiation for agricultural activities. We used daily meteorological data from weather station located in Jaboticabal, SP (coordinates: 21 ° 14'05 "South, 48 ° 17'09" West, 615m altitude at Universidade Estadual Paulista "Júlio Mesquita Filho" - FCAV/UNESP in a situation of default grass "Bahiagrass" during the period 20/08/2005 to 20/01/2012. The data used were the maximum temperature (Tmax, minimum (Tmin and mean (TMED; maximum relative humidity (URMáx, minimum (URMín and average (URMéd precipitation (mm, average velocity (m/s, Qo, solar radiation (MJ m-2, sunshine (hour meter (MJ m², soil temperature at two depths (Tsoil2CM, Tsoil5CM and class A pan evaporation (TCA (mm. The measures taken by the balance radiometer were taken as a reference to test other models. The models tested were those reported by NORMAN et al

  17. Change of notch impact strength depending on radiation dose and test temperature

    Directory of Open Access Journals (Sweden)

    Martin Bednarik

    2017-01-01

    Full Text Available The main purpose of this paper has been determine the effect of radiation crosslinking on the notch impact strength of polyamides filled with fiberglass. These properties were examined in dependence on the dosage of the ionizing beta radiation (non-irradiated samples and those irradiated by dosage 66 and 132 kGy were compared and on the test temperature (23–150 °C.

  18. Summary of the Manufacture, Testing and Model Validation of a Full-Scale Radiator for Fission Surface Power Applications

    Science.gov (United States)

    Ellis, David L.; Calder, James; Siamidis, John

    2011-01-01

    A full-scale radiator for a lunar fission surface power application was manufactured by Material innovations, Inc., for the NASA Glenn Research Center. The radiator was designed to reject 6 kWt with an inlet water temperature of 400 K and a water mass flow rate of 0.5 kg/s. While not flight hardware, the radiator incorporated many potential design features and manufacturing techniques for future flight hardware. The radiator was tested at NASA Glenn Research Center for heat rejection performance. The results showed that the radiator design was capable of rejecting over 6 kWt when operating at the design conditions. The actual performance of the radiator as a function of operational manifolds, inlet water temperature and facility sink temperature was compared to the predictive model developed by NASA Glenn Research Center. The results showed excellent agreement with the model with the actual average face sheet temperature being within 1% of the predicted value. The results will be used in the design and production of NASA s next generation fission power heat rejection systems. The NASA Glenn Research Center s Technology Demonstration Unit will be the first project to take advantage of the newly developed manufacturing techniques and analytical models.

  19. Report of test and research results on atomic energy obtained in national institutes in fiscal 1986

    International Nuclear Information System (INIS)

    1988-01-01

    The test and research regarding the utilization of atomic energy carried out in national institutions have produced many valuable results in diverse fields so far, such as nuclear fusion, safety research, food irradiation and medicine, since the budget had been appropriated for the first time in 1956. It has accomplished large role in the promotion of atomic energy utilization in Japan. This report is volume 27, in which the results of the test and research on atomic energy utilization carried out by national institutions in fiscal year 1986 are summarized. It is hoped that the understanding about the recent trend and the results of the test and research on atomic energy utilization is further promoted by this report. The contents of this report are nuclear fusion; the research on engineering safety and environmental radioactivity safety; food irradiation; the countermeasures against cancer; fertilized soil, the improvement of quality, the protection of plants and the improvement of breeding in agriculture and fishery fields; diagnosis and medical treatment, pharmaceuticals, environmental hygiene and the application to physiology and pathology in medical field; radiation chemistry and radiation measurement in mining and industry fields; nuclear reactor materials and nuclear-powered ships; civil engineering; radioactivation analysis; and the research on the prevention of injuries. (Kako, I.)

  20. Report of test and research results on atomic energy obtained in national institutes in fiscal 1984

    International Nuclear Information System (INIS)

    1985-01-01

    The test and research regarding the utilization of atomic energy carried out in national institutions have produced many valuable results in diverse fields so far, such as nuclear fusion, safety research, food irradiation and medicine, since the budget had been appropriated for the first time in 1956. It has accomplished large role in the promotion of atomic energy utilization in Japan. This report is Volume 25, in which the results of the test and research on atomic energy utilization carried out by national institutions in fiscal year 1984 are summarized. It is hoped that the understanding about the recent trend and the results of the test and research on atomic energy utilization is further promoted by this report. The contents of this report are nuclear fusion; the research on engineering safety and environmental radioactivity safety; food irradiation; the countermeasures against cancer; fertilized soil, the improvement of quality, the protection of plants and the improvement of breeding in agriculture and fishery fields; diagnosis and medical treatment, pharmaceuticals, environmental hygiene and the application to physiology and pathology in medical field; radiation chemistry and radiation measurement in mining and industry fields; nuclear reactor materials and nuclear-powered ships; civil engineering; radioactivation analysis; and the research on the prevention of injuries. (Kako, I.)

  1. Reliability test: X-ray ring exit chambers crotch radiation absorbers. Final report

    International Nuclear Information System (INIS)

    Lynch, D.R.; Morgan, J.

    1999-01-01

    This report details the efforts by engineers at the National Synchrotron Light Source (NSLS) of Brookhaven National Laboratory (BNL) to evaluate the reliability of water-cooled radiation absorbers used in the NSLS X-ray ring. These absorbers are part of the 16 dipole vacuum chambers which comprise the arc sections of the ring. They are located at the intersections (crotch) of the beamline exit ports with the electron beam chamber, and are commonly referred to as crotches. The purpose of these efforts was to demonstrate the reliability of the crotches under operating conditions that the crotches will be subjected to over the entire expected life of the ring. The efforts described include engineering calculations, finite element analysis, conceptual design for a reliability test, test implementation and descriptions, results and conclusions related to these analyses and tests

  2. First irradiation test results of the ALICE SAMPA ASIC

    CERN Document Server

    Mahmood, Sohail Musa; Winje, Fredrik Lindseth; Velure, Arild

    2018-01-01

    With the continuous scaling of the CMOS technology, the CMOS circuits are considered to be more tolerant to Single event Latchup (SEL) effects due to the reduction in the supply voltages. This paper reports the results from SEL testing performed on the first two prototypes for the new readout ASIC (SAMPA). During RUN 3/RUN 4 at the Large Hadron Collider (LHC), the SAMPA chip will be used for the upgrade of read-out front end electronics of the ALICE (A Large Ion Collider Experiment) Time Projection Chamber (TPC) and Muon Chambers (MCH). The first prototype MPW1 and the second prototype V2 of the SAMPA chip were delivered in 2015 and 2016, respectively. The results are summarized from two different proton beam irradiation campaigns, conducted for SAMPA MPW1 and V2 prototypes at The Svedberg Laboratory (TSL) in Uppsala, and the Center of Advanced Radiation Technology (KVI) in Groningen, respectively.

  3. A Research Agenda for Radiation Oncology: Results of the Radiation Oncology Institute's Comprehensive Research Needs Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Jagsi, Reshma, E-mail: rjagsi@med.umich.edu [Department of Radiation Oncology, University of Michigan, Ann Arbor, MI (United States); Bekelman, Justin E. [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA (United States); Brawley, Otis W. [Department of Hematology and Oncology, Emory University, and American Cancer Society, Atlanta, Georgia (United States); Deasy, Joseph O. [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Le, Quynh-Thu [Department of Radiation Oncology, Stanford University, Stanford, CA (United States); Michalski, Jeff M. [Department of Radiation Oncology, Washington University, St. Louis, MO (United States); Movsas, Benjamin [Department of Radiation Oncology, Henry Ford Health System, Detroit, MI (United States); Thomas, Charles R. [Department of Radiation Oncology, Oregon Health and Sciences University, Portland, OR (United States); Lawton, Colleen A. [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, WI (United States); Lawrence, Theodore S. [Department of Radiation Oncology, University of Michigan, Ann Arbor, MI (United States); Hahn, Stephen M. [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA (United States)

    2012-10-01

    Purpose: To promote the rational use of scarce research funding, scholars have developed methods for the systematic identification and prioritization of health research needs. The Radiation Oncology Institute commissioned an independent, comprehensive assessment of research needs for the advancement of radiation oncology care. Methods and Materials: The research needs assessment used a mixed-method, qualitative and quantitative social scientific approach, including structured interviews with diverse stakeholders, focus groups, surveys of American Society for Radiation Oncology (ASTRO) members, and a prioritization exercise using a modified Delphi technique. Results: Six co-equal priorities were identified: (1) Identify and develop communication strategies to help patients and others better understand radiation therapy; (2) Establish a set of quality indicators for major radiation oncology procedures and evaluate their use in radiation oncology delivery; (3) Identify best practices for the management of radiation toxicity and issues in cancer survivorship; (4) Conduct comparative effectiveness studies related to radiation therapy that consider clinical benefit, toxicity (including quality of life), and other outcomes; (5) Assess the value of radiation therapy; and (6) Develop a radiation oncology registry. Conclusions: To our knowledge, this prioritization exercise is the only comprehensive and methodologically rigorous assessment of research needs in the field of radiation oncology. Broad dissemination of these findings is critical to maximally leverage the impact of this work, particularly because grant funding decisions are often made by committees on which highly specialized disciplines such as radiation oncology are not well represented.

  4. Non-grey benchmark results for two temperature non-equilibrium radiative transfer

    International Nuclear Information System (INIS)

    Su, B.; Olson, G.L.

    1999-01-01

    Benchmark solutions to time-dependent radiative transfer problems involving non-equilibrium coupling to the material temperature field are crucial for validating time-dependent radiation transport codes. Previous efforts on generating analytical solutions to non-equilibrium radiative transfer problems were all restricted to the one-group grey model. In this paper, a non-grey model, namely the picket-fence model, is considered for a two temperature non-equilibrium radiative transfer problem in an infinite medium. The analytical solutions, as functions of space and time, are constructed in the form of infinite integrals for both the diffusion description and transport description. These expressions are evaluated numerically and the benchmark results are generated. The asymptotic solutions for large and small times are also derived in terms of elementary functions and are compared with the exact results. Comparisons are given between the transport and diffusion solutions and between the grey and non-grey solutions. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  5. Genetical variability of Gladioli as the result of gamma-radiation

    International Nuclear Information System (INIS)

    Jakota, L.I.; Murin, A.V.

    1994-01-01

    In the starting material of Gladioli, got in the result of Y-radiation, the forms with white spots on the petals were observed. The Gladioli form 165-81 is distinguished by low growth and middle early flowering. The flower form is triangular. Basic pigmentation is red. White spots of different size on the petals were observed. The investigation was made in 1992 in the field of genetical variability of Gladioli. The Gladioli form 165-81 was irradiated with gamma-radiation dose 30 Gr. As a result the depression of biometric indicators was observed. Consequently, 30 Gr is a mutant dose for Gladioli

  6. Test and Evaluation of Fiber Optic Sensors for High-Radiation Space Nuclear Power Applications

    International Nuclear Information System (INIS)

    Klemer, Daniel; Fielder, Robert S.; Stinson-Bagby, Kelly L.

    2004-01-01

    Fiber optic sensors can be used to measure a number of parameters, including temperature, strain, pressure and flow, for instrumentation and control of space nuclear power systems. In the past, this technology has often been rejected for use in such a high-radiation environment based on early experiments that revealed a number of degradation phenomena, including radiation-induced fiber attenuation, or 'graying', and Fiber Bragg Grating (FBG) fading and wavelength shift. However, this paper reports the results of recent experimental testing that demonstrates readability of fiber optic sensors to extremely high levels of neutron and gamma radiation. Both distributed Fiber Bragg Grating (FBG) sensors and single-point Extrinsic Fabry Perot Interferometer (EFPI) sensors were continuously monitored over a 2-month period, during which they were exposed to combined neutron and gamma radiation in both in-core and ex-core positions within a nuclear reactor. Total exposure reached approximately 2 x 10 19 cm -2 fast neutron (E > 1 MeV) fluence and 8.7 x 10 8 Gy gamma for in-core sensors. FBG sensors were interrogated using a standard Luna Innovations FBG measurement system, which is based on optical frequency-domain reflectometer (OFDR) technology. Approximately 74% of the 19 FBG sensors located at the core centerline in the in-core position exhibited sufficient signal-to-noise ratio (SNR) to remain readable even after receiving the maximum dose. EFPI sensors were spectrally interrogated using a broadband probe source operating in the 830 nm wavelength region. While these single-point sensors failed early in the test, important additional fiber spectral transmission data was collected, which indicates that interrogation of EFPI sensors in alternate wavelength regions may allow significant improvement in sensor longevity for operation in high-radiation environments. This work was funded through a Small Business Innovative Research (SBIR) contract with the Nasa Glenn Research

  7. Dual energy CT intracranial angiography: image quality, radiation dose and initial application results

    International Nuclear Information System (INIS)

    Chai Xue; Zhang Longjiang; Lu Guangming; Zhou Changsheng

    2009-01-01

    Objective: To assess the clinical value of dual-energy intracranial CT angiography (CTA). Methods: Forty-one patients suspected of intracranial vascular diseases underwent dual-energy intracranial CT angiography, and 41 patients who underwent conventional subtraction CT were enrolled as the control group. Image quality of intracranial and skull base vessels and radiation dose between dual-energy CTA and conventional subtraction CTA were compared using two independent sample nonparametric test and independent-samples t test, respectively. Prevalence and size of lesions detected by dual-energy CTA and digital subtraction CTA were compared using paired-samples t test and Spearman correlative analysis. Results: The percentage of image quality scored 5 was 70.7% (29/41) for dual-energy CTA and 75.6% (31/41) for conventional subtraction CTA. There was no significant difference between the two groups (Z= -0.455, P=0.650). Image quality of vessels at the skull base in conventional subtraction CTA was superior to that in dual-energy CTA, especially for the petrosal and syphon segment (Z=-4.087, P=0.000). Radiation exposure of dual energy CTA and conventional CTA were (396.54±17.43) and (1090.95±114.29) mGy·cm respectively. Radiation exposure was decreased by 64% (t=-38.52, P=0.000) by dual energy CTA compared with conventional subtraction CTA. Out of the 41 patients, 19 patients were diagnosed as intracranial aneurysm, 2 patients as arteriovenous malformation (AVM), 3 patients with Moya-moya's disease, and the remaining 17 patients with negative results. Nine patients with intracranial aneurysm, 2 patients with AVM, 3 patients with Moya-moya's disease, and 2 patients with negative findings underwent DSA or operation, with concordant findings from both techniques. Diameter of aneurysm neck, long axis and minor axis by dual-energy CTA was (2.90±1.61), (5.23±1.68) and (3.83±1.69) mm, respectively; Diameter of aneurysm neck, long axis and minor axis by DSA was (2.95±1

  8. Recent results on the effect of gamma radiation on the durability and microstructure of DWPF glass

    International Nuclear Information System (INIS)

    Bibler, N.E.; Tosten, M.H.; Beam, D.C.

    1989-01-01

    The effect of gamma radiation on the durability and microstructure of a simulated nuclear waste glass from the Savannah River Site has been carefully investigated. Three large pieces of glass were irradiated with a Co-60 source to three doses up to a maximum dose of 3.1 x 10 10 rad. Internal samples of the large pieces of irradiated and unirradiated glass were leached in deionized water to investigate durability changes and were examined by transmission electron microscopy (TEM) to investigate microstructure changes. Leach tests were performed in triplicate at 90 degree C with crushed glass samples in deionized water. A statistical analysis of the results indicated to the 95% confidence level that the radiation did not affect the glass durability. Careful examination by TEM indicated no effect of gamma radiation on the microstructure of the glass although severe damage could be induced by the electron beam from the microscope. 19 refs., 2 figs., 3 tabs

  9. Development of quality assurance programme for prescribed ionizing radiation source testing. Recommendations

    International Nuclear Information System (INIS)

    1999-01-01

    The document gives guidance to those applying for licence to perform ionizing radiation source acceptance tests and long-term stability tests and provides information which should be known when introducing quality assurance systems in compliance with legislative requirements. It is envisaged that this document ('Recommendations') will form a basis for final Safety Guides to be issued by the State Office for Nuclear Safety, the Czech nuclear regulatory authority. The setup of the publication is as follows. Part I gives a glossary of basic terms in quality systems. Part 2 explains quality system principles, paying special attention to radiation safety issues, and describes the structure and scope of quality system documentation. Part 3 explains the individual elements of the quality system and gives practical examples. Part 4 deals with the quality assurance programme; using instructions and practical examples, this part shows how the quality system elements should be applied to long-time stability testing and acceptance testing. A model structure of 2nd degree documentation (guidelines) and a model testing protocol are given in annexes. (P.A.)

  10. New radiation warning sign

    International Nuclear Information System (INIS)

    Mac Kenzie, C.; Mason, C.

    2006-01-01

    Full text: Radiation accidents involving orphan radioactive sources have happened as a result of people not recognizing the radiation trefoil symbol or from being illiterate and not understanding a warning statement on the radiation source. The trefoil symbol has no inherent meaning to people that have not been instructed in its use. A new radiation warning sign, to supplement the existing trefoil symbol, has been developed to address these issues. Human Factors experts, United Nations member states, and members of the international community of radiation protection professionals were consulted for input on the design of a new radiation warning sign that would clearly convey the message of 'Danger- Run Away- Stay Away' when in close proximity to a dangerous source of radiation. Cultural differences of perception on various warning symbols were taken into consideration and arrays of possible signs were developed. The signs were initially tested in international children for identification with the desired message and response. Based on these test results and further input from radiation protection professionals, five warning signs were identified as the most successful in conveying the desired message and response. These five signs were tested internationally in eleven countries by a professional survey company to determine the best sign for this purpose. The conclusion of the international testing is presented. The new radiation warning sign is currently a draft ISO standard under committee review. The design of the propose d radiation warning sign and the proposed implementation strategy outlined in the draft ISO standard is presented. (authors)

  11. A screening model for depleted uranium testing using environmental radiation monitoring data

    International Nuclear Information System (INIS)

    Dunfrund, F.L.; Ebinger, M.H.; Hansen, W.R.

    1996-01-01

    Information from an ecological risk assessment of depleted uranium test areas at Yuma Proving Ground (YPG) was used to update the required environmental radiation monitoring (ERM) plan. Data to be collected for the ERM can also be used to evaluate the potential for adverse radiological and toxicological effects to terrestrial reptiles and mammals in the affected areas. We developed a spreadsheet-based screening model that incorporates the ERM data and associated uncertainties. The purpose of the model is to provide a conservative estimate of radiological exposure of terrestrial, biota to DU using the ERM data. The uncertainty in the estimate is also predicted so that the variation in the radiological exposure can be used in assessing potential adverse effects from DU testing. Toxicological effects are evaluated as well as radiological effects in the same program using the same data. Our presentation shows an example data set, model calculations, and the report of expected radiation dose rates and probable kidney burdens of select mammals and reptiles. The model can also be used in an inverse mode to calculate the soil concentration required to give either a radiological dose that would produce a potential adverse effect such as fatal cancer or a toxicological dose that would result in nephrotoxic effects in mammals

  12. Ion chamber-electrometer measurement system for radiation protection tests in X-ray equipment for interventional procedures

    International Nuclear Information System (INIS)

    Bottaro, Marcio

    2012-01-01

    A new parallel plate ionization chamber with volume of 500 cc and an electrometer with digital interface for data acquisition, configuring an ion chamber electrometer measurement system, were developed to comply with specific requirements for compulsory radiation protection tests in interventional X-ray equipment. The ion chamber has as main characteristics: low cost, mechanical strength and response variation with beam energy of less than 5% in the 40 kV to 150 kV range. The electrometer has a high gain (5x10 8 V/A) transimpedance amplifier circuit and a data acquisition and control system developed in LabVIEW ® platform, including an integrated power supply for the ion chamber bias with adjustable DC voltage output from O to 1000 V and an air density correction system. Electric field calculations, laboratory measurements in standard beams and computational simulations of radiation interactions in chamber volume with Monte Carlo Method were employed in the elaborated methodology of the ion chamber development, which was tested and validated. It was also developed a simplified methodology for electrometer calibration that assures metrological trustworthiness of the measurement system. Tests for the system performance evaluation as environmental influence response, energy response, angular dependency, linearity and air kerma and air kerma rate dependency were performed according to international standards and requirements. Additionally, for a detailed evaluation of the developed ion chamber, simulations with various scattered radiation spectra were performed. The system was applied in leakage radiation, residual radiation and scattered radiation tests, being compared with other reference systems and validated for laboratorial test routine. (author)

  13. Definitions, qualifications and requirements for radiation protection experts, radiation protection officers and radiation workers: results of the 2 nd EUTERP Workshop

    International Nuclear Information System (INIS)

    Draaisma, Folkert S.; Steen, Jan van der

    2008-01-01

    Full text: In Europe, a common vision for maintaining competence in radiation protection is emerging, focussing on a common denominator for qualification of radiation protection experts (RPEs) and radiation protection officers (RPOs) and for mutual recognition and mobility of these professionals across the European Union. Therefore, the European Commission, D.-G. Transport and Energy, has launched an initiative to establish a European Radiation Protection Training and Education Platform (EUTERP Platform). The objectives of the Platform can be summarised as: to facilitate the trans national access to vocational education and training; to better integrate education and training into occupational radiation protection infrastructures in the Member, Candidate and Associated States of the European Union. The Platform ensures a permanent dialogue between all involved parties by the use of its web site (www.euterp.eu), by issuing newsletters and by organising workshops. The first workshop has been held in Vilnius, 22-24 May 2007, and resulted in 8 recommendations to the European Commission, the IAEA, IRPA and national authorities. The recommendations were, a.o., dealing with: new definitions for the Radiation Protection Expert (RPE) and the Radiation Protection Officer (RPO), which should be used in the revision of both the EURATOM and the International BSS; developing guidance for a methodology to compare the quality of training courses and training material; developing guidance for a standardized methodology of assessing the recognition of RP professionals as a basis for future mutual recognition, based on a description of roles and duties, education, training and work experience; developing guidance for a formal recognition process of the competence of RPEs and RPOs. The second workshop will be held on 23-25 April 2008, again in Vilnius, and will specifically discuss the above-mentioned proposals for new definitions and guidance material. It is expected that the

  14. SU-E-T-243: Design of a Novel Testing Port for Radiation Protection and Shielding Measurements

    International Nuclear Information System (INIS)

    Tanny, S; Parsai, E; Harrell, D; Noller, J; Chopra, M

    2015-01-01

    Purpose: The majority of radiation shielding research utilizes Monte Carlo simulation because of the difficulty in eliminating secondary radiations from measurements. We have designed a test port into a primary barrier of our newest vault to allow for shielding measurements while ensuring adequate protection to the public and staff during normal machine operation. This port allows for measurement of attenuation values of shielding materials, differential dose albedos, and radiation scatter fractions. Methods: The vault design utilized the maze as part of a compound primary barrier. The test port is contained within the maze and is centered along isocenter. The inner 30 cm has a 20×20 cm 2 opening, while the remaining length has a 30×30 cm 2 opening. The block that contains the port has a density of 200 pcf to minimize internal scatter. The 30×30 cm 2 opening is occupied by removable 215 pcf concrete blocks. The innermost and outermost blocks activate an interlock wired into the beam-enable loop. This disallows beam-on in treatment mode if the interlock isn’t closed. The interlock can be overridden in service mode, or by-passed via an override switch in case of circuit failure. Results: The test port was installed in August. The beam is disabled when the interlock is tripped. Measurements taken when the primary beam is not incident on the port are indistinguishable from background. Ambient dose levels surrounding the vault with the designed shielding blocks in place are all within allowable limits for occupational workers. Conclusions: We have designed and installed a unique testing port for radiation protection and shielding measurements. This port is appropriately interlocked and designed to mitigate any risks of incidental exposure to staff or members of the public. The test port design allows measurements with “good geometry” and efficient removal of contaminating sources of radiation present in many shielding measurements. Daniel Harrell and Jim Noller

  15. Radiation protection training award - an innovative approach of testing radiation protection skills in catastrophe management

    International Nuclear Information System (INIS)

    Geringer, T.

    2003-01-01

    Full text: ARC Seibersdorf research is Austria's largest independent research institution. Apart from research and technical development, ARCS also offers special training an radiation protection. Having undergone intensive radiation protection training, security forces are also entitled to test their knowledge in a special 'radiation protection training award'. The prize is awarded in three different grades. ARCS Bronze award guarantees that the holder is competent in, both theoretical and practical aspects of a radiological accident. The follow-up Silver award requires additional competence in emergency management. Candidates having at least five years of professional experience and presenting a written thesis are considered for the Golden award. The holder is not only experienced in radiological catastrophe management including a competent theoretical background, but is also experienced enough to work out and improve his own emergency planning. ARC Seibersdorf research started with their radiation protection award as early as 1968. More then 10 000 candidates have been awarded since then. Most candidates are members of the Austrian Army or other security forces, although everyone above the age of 18 and undergone a basic course in radiation protection is entitled to participate. Even company internal awards have been given to ensure the quality of training applies to ARC Seibersdorf members as well. The prize is awarded in three different grades. ARCS Bronze award guarantees that the holder is competent in both theoretical and practical aspects of a radiological accident. The followup Silver award requires additional competence in emergency management. Candidates having at least five years of professional experience and presenting a written thesis, are considered for the Golden award. The holder is not only experienced in radiological catastrophe management including a competent theoretical background, but is also experienced enough to work out and improve his

  16. Instrumentation measurement and testing complex for detection and identification of radioactive materials using the emitted radiation

    International Nuclear Information System (INIS)

    Samossadny, V.T.; Dmitrenko, V.V.; Kadlin, V.V.; Kolesnikov, S.V.; Ulin, S.E.; Grachev, V.M.; Vlasik, K.F.; Dedenko, G.L.; Novikov, D.V.; Uteshev, Z.M.

    2006-01-01

    Simultaneous measurement of neutron and gamma radiation is a very usefull method for effective nuclear materials identification and control. The gamma-ray-neutron complex described in the paper is based on two multi-layer 3 He neutrons detectors and two High Pressure Xenon gamma-ray spectrometers assembled in one unit. All these detectors were callibrated on neutron and gamma-ray sources. The main characteristics of the instrumentation , its testing results and gamma-ray and neutron radiation parameters, which have been measured are represented in the paper. The gamma-neutron sources and fissile materials reliable detection and identification capability was demonstrated

  17. In situ mechanical-radiation effects test capsule for simulating fusion material environments

    International Nuclear Information System (INIS)

    Christensen, K.E.; Bennett, G.A.; Sommer, W.F.

    1981-01-01

    Conditions of radiation and simultaneous cyclic stress on materials are inherent in advanced energy source designs such as inertially and magnetically confined controlled thermonuclear reactors. A test capsule capable of applying a cyclic stress to test specimens while they are being irradiated in the 800-MeV proton beam at the Clinton P. Anderson Los Alamos Meson Physics Facility has been developed. The design and performance of this device are discussed in this report. This machine has facilities for seven pairs of differential samples; one sample of a pair receives an applied cyclic stress and its companion in an identical flux will be the unstressed control. Control of the sample temperature and in situ monitoring of sample elongation and load are provided in the design. Results of an earlier experiment will be discussed, along with those of preliminary bench tests of the redesigned capsule

  18. Radiation protection research and training programme review radiation protection programme 1960-89 synopsis of results 1985-89

    International Nuclear Information System (INIS)

    1990-01-01

    This document aims to trace the evolution of the CEC radiation protection programme over its 30 years of existence. During this time, research carried out in the framework of the Community programme has made major contributions to the scientific understanding of the action of ionizing radiation and the protection of man and his environment. This information was crucial for developing better radiation protection management for existing and new technologies and for providing the scientific basis for the regulatory activities of the Commission. One important feature of the programme was the success of bringing together scientists from different Member States to cooperate in the various fields of radiation protection and to integrate different areas of radiation protection research into a coherent approach. The structures thus developed within the programme have enabled research in radiation protection to be conducted in a cost-effective manner on behalf of the Member States. This document aims also to give a synopsis of the most important results of the 1985-89 radiation protection programme. This period was characterized by two challenges, the integration of two Member States into Community research and the impact of the Chernobyl accident. The programme has, in spite of reduced funding, continued to provide a high degree of expertise for the Community in the context of the needs in radiation protection. This has been explicity acknowledged in the evaluation of the 1980-89 programmes carried out by an independent panel

  19. Monitoring system for testing the radiation hardness of a KINTEX-7 FPGA

    Energy Technology Data Exchange (ETDEWEB)

    Cojocariu, L. N., E-mail: lucian.cojocariu@cern.ch [Horia Hulubei National Institute for R& D in Physics and Nuclear Engineering (Reactorului 30, MG, Romania) (Romania); Stefan cel Mare University of Suceava (Universitatii 13, Suceava, Romania) (Romania); Placinta, V. M., E-mail: vlad-mihai.placinta@cern.ch [Horia Hulubei National Institute for R& D in Physics and Nuclear Engineering (Reactorului 30, MG, Romania) (Romania); University POLITEHNICA of Bucharest (Splaiul Independentei 313, Bucharest, Romania) (Romania); Dumitru, L., E-mail: dlaur@nipne.ro [Horia Hulubei National Institute for R& D in Physics and Nuclear Engineering (Reactorului 30, MG, Romania) (Romania)

    2016-03-25

    A much more efficient Ring Imaging Cherenkov sub-detector system will be rebuilt in the second long shutdown of Large Hadron Collider for the LHCb experiment. Radiation-hard electronic components together with Commercial Off-The-Shelf ones will be used in the new Cherenkov photon detection system architecture. An irradiation program was foreseen to determine the radiation tolerance for the new electronic devices, including a Field Programmable Gate Array from KINTEX-7 family of XILINX. An automated test bench for online monitoring of the XC7K70T KINTEX-7 device operation in radiation conditions was designed and implemented by the LHCb Romanian group.

  20. Design, fabrication, and dynamic testing of a V-groove radiator mechanical development unit

    Science.gov (United States)

    Petrick, S. Walter; Bard, Steven

    1988-01-01

    This paper describes the design, fabrication, and dynamic testing of a V-groove radiator development unit. The intended goal was to survive the dynamic environment of the Mars Observer mission. The development unit was designed to achieve a temperature of 80 K with a heat load of about 80 milliwatts. An analysis was performed to predict the thermal performance of the development unit. The radiator with a mass mockup of a Gamma Ray Spectrometer detector, the most massive of the candidate Mars Observer instrument detectors (1.7 Kg), passed vibration and acoustic testing to the Mars Observer requirements in effect at that time.

  1. PSA Solar furnace: A facility for testing PV cells under concentrated solar radiation

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez-Reche, J.; Canadas, I.; Sanchez, M.; Ballestrin, J.; Yebra, L.; Monterreal, R.; Rodriguez, J.; Garcia, G. [Concentration Solar Technologies, Plataforma Solar de Almeria-CIEMAT P.O. Box 22, Tabernas, E-04200 (Almeria) (Spain); Alonso, M.; Chenlo, F. [Photovoltaic Components and Systems, Renewable Energies Department-CIEMAT Avda. Complutense, 22, Madrid, E-28040 (Spain)

    2006-09-22

    The Plataforma Solar de Almeria (PSA), the largest centre for research, development and testing of concentration solar thermal technologies in Europe, has started to apply its knowledge, facilities and resources to development of the Concentration PV technology in an EU-funded project HiConPV. A facility for testing PV cells under solar radiation concentrated up to 2000x has recently been completed. The advantages of this facility are that, since it is illuminated by solar radiation, it is possible to obtain the appropriate cell spectral response directly, and the flash tests can be combined with prolonged PV-cell irradiation on large surfaces (up to 150cm{sup 2}), so the thermal response of the PV cell can be evaluated simultaneously. (author)

  2. Radiative transfer with finite elements. Pt. 1. Basic method and tests

    Energy Technology Data Exchange (ETDEWEB)

    Richling, S. [Heidelberg Univ. (Germany). Inst. fuer Theoretische Astrophysik; Meinkoehn, E. [Heidelberg Univ. (Germany). Inst. fuer Theoretische Astrophysik]|[Heidelberg Univ. (Germany). Inst. fuer Angewandte Mathematik; Kryzhevoi, N. [Heidelberg Univ. (Germany). Inst. fuer Theoretische Astrophysik]|[Heidelberg Univ. (DE). Interdisziplinaeres Zentrum fuer Wissenschaftliches Rechnen (IWR); Kanschat, G. [Heidelberg Univ. (Germany). Inst. fuer Angewandte Mathematik]|[Heidelberg Univ. (DE). Interdisziplinaeres Zentrum fuer Wissenschaftliches Rechnen (IWR)

    2001-10-01

    A finite element method for solving the monochromatic radiation transfer equation including scattering in three dimensions is presented. The algorithm employs unstructured grids which are adaptively refined. Adaptivity as well as ordinate parallelization reduce memory requirements and execution time and make it possible to calculate the radiation field across several length scales for objects with strong opacity gradients. An a posteriori error estimate for one particular quantity is obtained by solving the dual problem. The application to a sample of test problems reveals the properties of the implementation. (orig.)

  3. Report of the actual conditions of the radiation exposed residents near the former Semipalatinsk nuclear test site

    International Nuclear Information System (INIS)

    Kawano, Noriyuki; Taooka, Yasuyuki; Hiraoka, Takashi; Hoshi, Masaharu; Shaimardanovich, Z.Z.

    2004-01-01

    Hiroshima Peace Science Consortium, established in 2002 as part of the local cooperation project of Hiroshima University for peace science, conducted a field research in Semipalatinsk and related areas in 2002 to collect and analyze data on health effects of radiation experiences of people exposed to nuclear test radiation. This book is a report of the research and contains Introductory remarks; 6 chapters of Overview of the study, Medical information analysis on the radiation exposed residents near the former Semipalatinsk nuclear test site using questionnaire, Content analysis of testimonies written by hibakusha near the nuclear test site of Semipalatinsk, Comments on the interview, Significance of collecting testimonies of those exposed to radiation in Semipalatinsk, Kazakhstan/in comparison with those of Hiroshima and Nagasaki, and Future tasks and prospective; Conclusion; and 2 Appendices of Research on the conditions of radiation exposure survey response sheet and Testimonies. (N.I.)

  4. Testing results of Monte Carlo sampling processes in MCSAD

    International Nuclear Information System (INIS)

    Pinnera, I.; Cruz, C.; Abreu, Y.; Leyva, A.; Correa, C.; Demydenko, C.

    2009-01-01

    The Monte Carlo Simulation of Atom Displacements (MCSAD) is a code implemented by the authors to simulate the complete process of atom displacement (AD) formation. This code makes use of the Monte Carlo (MC) method to sample all the processes involved in the gamma and electronic radiation transport through matter. The kernel of the calculations applied to this code relies on a model based on an algorithm developed by the authors, which firstly splits out multiple electron elastic scattering events from those single ones at higher scattering angles and then, from the last one, sampling those leading to AD at high transferred atomic recoil energies. Some tests have been developed to check the sampling algorithms with the help of the corresponding theoretical distribution functions. Satisfactory results have been obtained, which indicate the strength of the methods and subroutines used in the code. (Author)

  5. Heat resistant/radiation resistant cable and incore structure test device for FBR type reactor

    International Nuclear Information System (INIS)

    Tanimoto, Hajime; Shiono, Takeo; Sato, Yoshimi; Ito, Kazumi; Sudo, Shigeaki; Saito, Shin-ichi; Mitsui, Hisayasu.

    1995-01-01

    A heat resistant/radiation resistant coaxial cable of the present invention comprises an insulation layer, an outer conductor and a protection cover in this order on an inner conductor, in which the insulation layer comprises thermoplastic polyimide. In the same manner, a heat resistant/radiation resistant power cable has an insulation layer comprising thermoplastic polyimide on a conductor, and is provided with a protection cover comprising braid of alamide fibers at the outer circumference of the insulation layer. An incore structure test device for an FBR type reactor comprises the heat resistant/radiation resistant coaxial cable and/or the power cable. The thermoplastic polyimide can be extrusion molded, and has excellent radiation resistant by the extrusion, as well as has high dielectric withstand voltage, good flexibility and electric characteristics at high temperature. The incore structure test device for the FBR type reactor of the present invention comprising such a cable has excellent reliability and durability. (T.M.)

  6. Fission Surface Power Technology Demonstration Unit Test Results

    Science.gov (United States)

    Briggs, Maxwell H.; Gibson, Marc A.; Geng, Steven M.; Sanzi, James L.

    2016-01-01

    The Fission Surface Power (FSP) Technology Demonstration Unit (TDU) is a system-level demonstration of fission power technology intended for use on manned missions to Mars. The Baseline FSP systems consists of a 190 kWt UO2 fast-spectrum reactor cooled by a primary pumped liquid metal loop. This liquid metal loop transfers heat to two intermediate liquid metal loops designed to isolate fission products in the primary loop from the balance of plant. The intermediate liquid metal loops transfer heat to four Stirling Power Conversion Units (PCU), each of which produce 12 kWe (48 kW total) and reject waste heat to two pumped water loops, which transfer the waste heat to titanium-water heat pipe radiators. The FSP TDU simulates a single leg of the baseline FSP system using an electrically heater core simulator, a single liquid metal loop, a single PCU, and a pumped water loop which rejects the waste heat to a Facility Cooling System (FCS). When operated at the nominal operating conditions (modified for low liquid metal flow) during TDU testing the PCU produced 8.9 kW of power at an efficiency of 21.7 percent resulting in a net system power of 8.1 kW and a system level efficiency of 17.2 percent. The reduction in PCU power from levels seen during electrically heated testing is the result of insufficient heat transfer from the NaK heater head to the Stirling acceptor, which could not be tested at Sunpower prior to delivery to the NASA Glenn Research Center (GRC). The maximum PCU power of 10.4 kW was achieved at the maximum liquid metal temperature of 875 K, minimum water temperature of 350 K, 1.1 kg/s liquid metal flow, 0.39 kg/s water flow, and 15.0 mm amplitude at an efficiency of 23.3 percent. This resulted in a system net power of 9.7 kW and a system efficiency of 18.7 percent.

  7. Measurement results on environmental radioactivity in West Germany after the Chinese nuclear weapons test of September 26, 1976

    International Nuclear Information System (INIS)

    Huber, O.; Voelker, A.

    1977-09-01

    The atmospheric nuclear test carried out by the People's Republic of China on 26.9.1976 caused considerable amounts of radioactive fission products in the Federal Republic of Germany. The Measurement results obtained by the Federal institutions for monitoring environmental radioactivity made it possible to register and interpret at any time the levels and types of the fission products in the environmental sectors. There was no indication for any health hazards to the population. The maximum values of radiation exposure from 131I could be observed via the pasture-cow-milk-path. The values of the milk samples amounted up to 170 pCi/1. Infants with a daily milk consumption of 0,8 l received radiation doses to the thyroid of about 4 mrem. Apart from a compilation of the measurement results the report contains estimates of the radiation exposure via the individual exposure paths, data on the present general level of environmental radioactivity after the nuclear tests carried out in the last decades and a compilation of the long-lived fission products 90Sr and 137Cs which are deposited in the Federal Republic of Germany and incorporated by the population with food. (orig.) [de

  8. The relationship of thyroid cancer with radiation exposure from nuclear weapon testing in the Marshall Islands

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Tatsuya; Fukao, Akira [Yamagata Univ. (Japan). School of Medicine; Schoemaker, M.J. [Inst. of Cancer Research, Sutton, Surry (United Kingdom); Trott, K.R. [Gray Cancer Inst., Northwood, Middlesex (United Kingdom); Simon, S.L. [National Cancer Inst., Rockville, MD (United States); Fujimori, Keisei; Nakashima, Noriaki [Tohoku Univ., Sendai (Japan). Graduate School of Medicine; Saito, Hiroshi [Nagasaki Univ. (Japan). School of Medicine

    2003-03-01

    The US nuclear weapons testing program in the Pacific conducted between 1946 and 1958 resulted in radiation exposure in the Marshall Islands. The potentially widespread radiation exposure from radioiodines of fallout has raised concerns about the risk of thyroid cancer in the Marshallese population. The most serious exposures and its health hazards resulted from the hydrogen-thermonuclear bomb test, the Castle BRAVO, on March 1, 1954. Between 1993 and 1997, we screened 3,709 Marshallese for thyroid disease who were born before the BRAVO test. It was 60% of the entire population at risk and who were still alive at the time of our examinations. We diagnosed 30 thyroid cancers and found 27 other study participants who had been operated for thyroid cancer before our screening in this group. Fifty-seven Marshallese born before 1954 (1.5%) had thyroid cancer or had been operated for thyroid cancer. Nearly all (92%) of these cancers were papillary carcinoma. We derived estimates of individual thyroid dose proxy from the BRAVO test in 1954 on the basis of published age-specific doses estimated on Utirik atoll and {sup 137}Cs deposition levels on the atolls where the participants came from. There was suggestive evidence that the prevalence of thyroid cancer increased with category of estimated dose to the thyroid. (author)

  9. Mutant p53 transfection of astrocytic cells results in altered cell cycle control, radiation sensitivity, and tumorigenicity

    International Nuclear Information System (INIS)

    Kanady, Kirk E.; Mei Su; Proulx, Gary; Malkin, David M.; Pardo, Francisco S.

    1995-01-01

    Introduction: Alterations in the p53 tumor suppressor gene are one of the most frequent genetic alterations in malignant gliomas. An understanding of the molecular genetic events leading to glial tumor progression would aid in designing therapeutic vectors for controlling these challenging tumor types. We investigated whether mutations in coding exons of the p53 gene result in functional changes altering cell cycle 'checkpoint' control and the intrinsic radiation sensitivity of glial cells. Methods: An astrocytic cell line was derived from a low grade astrocytoma and characterized to be of human karyotype and GFAP positivity. Additionally, the cellular population has never formed tumors in immune-deficient mice. At early passage ( 2 as parameters. Cell kinetic analyses after 2, 5, and 10 Gy of ionizing radiation were conducted using propidium iodide FACS analyses. Results: Overall levels of p53 expression were increased 5-10 fold in the transfected cellular populations. Astrocytic cellular populations transfected with mutant p53 revealed a statistically significant increase in levels of resistance to ionizing radiation in vitro (2-tailed test, SF2, MID). Astrocytic cellular populations transfected with mutant p53, unlike the parental cells, were tumorigenic in SCID mice. Cell kinetic analyses indicated that the untransfected cell line demonstrated dose dependent G1 and G2 arrests. Following transfection, however, the resultant cellular population demonstrated a predominant G2 arrest. Conclusions: Astrocytic cellular populations derived from low grade astrocytomas, are relatively radiation sensitive, non-tumorigenic, and have intact cell cycle ''checkpoints.'' Cellular populations resulting upon transfection of parental cells with a dominant negative p53 mutation, are relatively radiation resistant, when compared to both parental and mock-transfected cells. Transfected cells demonstrate abnormalities of cell cycle control at the G1/S checkpoint, increases in levels

  10. Standards for radiation protection instrumentation: design of safety standards and testing procedures

    International Nuclear Information System (INIS)

    Meissner, Frank

    2008-01-01

    This paper describes by means of examples the role of safety standards for radiation protection and the testing and qualification procedures. The development and qualification of radiation protection instrumentation is a significant part of the work of TUV NORD SysTec, an independent expert organisation in Germany. The German Nuclear Safety Standards Commission (KTA) establishes regulations in the field of nuclear safety. The examples presented may be of importance for governments and nuclear safety authorities, for nuclear operators and for manufacturers worldwide. They demonstrate the advantage of standards in the design of radiation protection instrumentation for new power plants, in the upgrade of existing instrumentation to nuclear safety standards or in the application of safety standards to newly developed equipment. Furthermore, they show how authorities may proceed when safety standards for radiation protection instrumentation are not yet established or require actualization. (author)

  11. Application of complex programmable logic devices in memory radiation effects test system

    International Nuclear Information System (INIS)

    Li Yonghong; He Chaohui; Yang Hailiang; He Baoping

    2005-01-01

    The application of the complex programmable logic device (CPLD) in electronics is emphatically discussed. The method of using software MAX + plus II and CPLD are introduced. A new test system for memory radiation effects is established by using CPLD devices-EPM7128C84-15. The old test system's function are realized and, moreover, a number of small scale integrated circuits are reduced and the test system's reliability is improved. (authors)

  12. Radiation Tests on the Complete System of the Instrumentation of the LHC Cryogenics at the CERN Neutrinos to Gran Sasso (CNGS) Test Facility

    CERN Document Server

    Gousiou, E; Casas Cubillos, J; de la Gama Serrano, J

    2009-01-01

    There are more than 6000 electronic cards for the instrumentation of the LHC cryogenics, housed in crates and distributed around the 27 km tunnel. Cards and crates will be exposed to a complex radiation field during the 10 years of LHC operation. Rad-tol COTS and rad-hard ASIC have been selected and individually qualified during the design phase of the cards. The test setup and the acquired data presented in this paper target the qualitative assessment of the compliance with the LHC radiation environment of an assembled system. It is carried out at the CNGS test facility which provides exposure to LHC-like radiation field.

  13. Assessment of genetic results of ionizing radiation effect on hydrobionts population

    International Nuclear Information System (INIS)

    Pechkurenkov, V.L.; Pokrovskaya, L.G.; Fetisov, A.N.

    1987-01-01

    The effect of dose value and rate on genetic results of chronic radiation with the low dose rate is estimated. At such irradiation the yield of abberant anaphases of embryos is determined by the dose value and it does not depend on the dose rate. The threshold radiation dose rate of the developing fish roe equals 2-3 cGy/h when ignoring the medium modifying factors. The estimation of possible limits of modification of genetic effects of radiation with the low rate when changing environmental factors is given. The model allowing to forecast the appearance of genetic effects of radiation with the low dose rate is constructed. The correspondence between the data obtained in laboratory experiments using organisms living in water reservoirs contaminated experimentally by radionuclides is marked

  14. Results of Radiation Therapy in Stage III Uterine Cervical Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Chang Woo; Shin, Byung Chul; Yum, Ha Yong; Jeung, Tae Sig; Yoo, Myung Jin [Kosin University College of Medicine, Seoul (Korea, Republic of)

    1995-09-15

    Purpose : The aim of this study is to analyze the survival rate, treatment failure and complication of radiation therapy alone in stage III uterine cervical cancer. Materials and Methods : From January 1980 through December 1985, 227 patients with stage II uterine cervical cancer treated with radiation therapy at Kosin Medical Center were retrospectively studied. Among 227 patients, 72 patients(31.7%) were stage IIIa, and 155 patients(68.3%) were stage IIIb according to FIGO classification. Age distribution was 32-71 years(median: 62 years). Sixty nine patients(95.8%) in stage IIIa and 150 patients(96.8%) in stage IIIb were squamous cell carcinoma. Pelvic lymph node metastasis at initial diagnosis was 8 patients (11.1%) in stage IIIa and 29 patients(18.7%) in stage IIIb. Among 72 patients with stage IIIa, 36 patients(50%) were treated with external radiation therapy alone by conventional technique (180-200 cGy/fr). And 36 patients(50%) were treated with external radiation therapy with intracavitary radiotherapy(ICR) with Cs137 sources, and among 155 patients with stage IIIb, 80 patients(51.6%) were treated with external radiation therapy alone and 75 patients(48.4%) were treated with external radiation therapy with ICR. Total radiation doses of stage IIIa and IIIb were 65-105 Gy(median : 78.5 Gy) and 65-125.5 Gy (median :83.5 Gy). Survival rate was calculated by life-table method. Results : Complete response rates were 58.3% (42 patients) in state IIIa and 56.1%(87 patients) in stage Iiib. Overall 5 year survival rates were 57% in stage IIIa and 40% in stage IIIb. Five year survival rates by radiation technique in stage IIIa and IIIb were 64%, 40% in group treated in combination of external radiation and ICR, and 50%, 40% in the group of external radiation therapy alone(P=NS). Five year survival rates by response of radiation therapy in stage IIIa and IIIb were 90%, 66% in responder group, and 10%, 7% in non-responder group (P<0.01). There were statistically no

  15. Results of Radiation Therapy in Stage III Uterine Cervical Cancer

    International Nuclear Information System (INIS)

    Moon, Chang Woo; Shin, Byung Chul; Yum, Ha Yong; Jeung, Tae Sig; Yoo, Myung Jin

    1995-01-01

    Purpose : The aim of this study is to analyze the survival rate, treatment failure and complication of radiation therapy alone in stage III uterine cervical cancer. Materials and Methods : From January 1980 through December 1985, 227 patients with stage II uterine cervical cancer treated with radiation therapy at Kosin Medical Center were retrospectively studied. Among 227 patients, 72 patients(31.7%) were stage IIIa, and 155 patients(68.3%) were stage IIIb according to FIGO classification. Age distribution was 32-71 years(median: 62 years). Sixty nine patients(95.8%) in stage IIIa and 150 patients(96.8%) in stage IIIb were squamous cell carcinoma. Pelvic lymph node metastasis at initial diagnosis was 8 patients (11.1%) in stage IIIa and 29 patients(18.7%) in stage IIIb. Among 72 patients with stage IIIa, 36 patients(50%) were treated with external radiation therapy alone by conventional technique (180-200 cGy/fr). And 36 patients(50%) were treated with external radiation therapy with intracavitary radiotherapy(ICR) with Cs137 sources, and among 155 patients with stage IIIb, 80 patients(51.6%) were treated with external radiation therapy alone and 75 patients(48.4%) were treated with external radiation therapy with ICR. Total radiation doses of stage IIIa and IIIb were 65-105 Gy(median : 78.5 Gy) and 65-125.5 Gy (median :83.5 Gy). Survival rate was calculated by life-table method. Results : Complete response rates were 58.3% (42 patients) in state IIIa and 56.1%(87 patients) in stage Iiib. Overall 5 year survival rates were 57% in stage IIIa and 40% in stage IIIb. Five year survival rates by radiation technique in stage IIIa and IIIb were 64%, 40% in group treated in combination of external radiation and ICR, and 50%, 40% in the group of external radiation therapy alone(P=NS). Five year survival rates by response of radiation therapy in stage IIIa and IIIb were 90%, 66% in responder group, and 10%, 7% in non-responder group (P<0.01). There were statistically no

  16. Results of performance tests on chemical and radiation measurement systems for use at a dig-face

    International Nuclear Information System (INIS)

    Gehrke, R.J.; Lawrence, R.S.; Pawelko, R.J.

    1995-04-01

    Chemical and radiation measurement systems are being developed for use at a dig-face to provide sensing capability during the excavation of previously buried waste. it is believed that on-line dig-face characterization will reduce environmental, health, and safety risks during the cleanup of buried waste sites as well as improve the efficiency of the cleanup process. This report describes progress in the development of three measurement systems: (a) a γ/neutron monitor that scans the dig-face for high levels of radiation prior to excavation, (b) a Ge spectrometer that identifies specific radionuclides located with the γ/neutron monitor, and (c) a prompt γ neutron activation analysis (PGNAA) system that measures the presence of chlorine and chlorinated compounds often associated with hazardous waste. The Ge spectrometer and PGNAA system also will provide off-line but on-site capability of radionuclide and elemental identification of excavated waste prior to handling, treatment, transportation, or disposal

  17. Radiation hardness tests of piezoelectric actuators with fast neutrons at liquid helium temperature

    Energy Technology Data Exchange (ETDEWEB)

    Fouaidy, M.; Martinet, G.; Hammoudi, N.; Chatelet, F.; Olivier, A.; Blivet, S.; Galet, F. [CNRS-IN2P3-IPN Orsay, Orsay (France)

    2007-07-01

    Piezoelectric actuators, which are integrated into the cold tuning system and used to compensate the small mechanical deformations of the cavity wall induced by Lorentz forces due to the high electromagnetic surface field, may be located in the radiation environment during particle accelerator operation. In order to provide for a reliable operation of the accelerator, the performance and life time of piezoelectric actuators ({approx}24.000 units for ILC) should not show any significant degradation for long periods (i.e. machine life duration: {approx}20 years), even when subjected to intense radiation (i.e. gamma rays and fast neutrons). An experimental program, aimed at investigating the effect of fast neutrons radiation on the characteristics of piezoelectric actuators at liquid helium temperature (i.e. T{approx}4.2 K), was proposed for the working package WPNo.8 devoted to tuners development in the frame of CARE project. A neutrons irradiation facility, already installed at the CERI cyclotron located at Orleans (France), was upgraded and adapted for actuators irradiations tests purpose. A deuterons beam (maximum energy and beam current: 25 MeV and 35{mu}A) collides with a thin (thickness: 3 mm) beryllium target producing a high neutrons flux with low gamma dose ({approx}20%): a neutrons fluence of more than 10{sup 14} n/cm{sup 2} is achieved in {approx}20 hours of exposure. A dedicated cryostat was developed at IPN Orsay and used previously for radiation hardness test of calibrated cryogenic thermometers and pressure transducers used in LHC superconducting magnets. This cryostat could be operated either with liquid helium or liquid argon. This irradiation facility was upgraded for allowing fast turn-over of experiments and a dedicated experimental set-up was designed, fabricated, installed at CERI and successfully operated for radiation hardness tests of several piezoelectric actuators at T{approx}4.2 K. This new apparatus allows on-line automatic measurements

  18. Radiation hardness tests of piezoelectric actuators with fast neutrons at liquid helium temperature

    International Nuclear Information System (INIS)

    Fouaidy, M.; Martinet, G.; Hammoudi, N.; Chatelet, F.; Olivier, A.; Blivet, S.; Galet, F.

    2007-01-01

    Piezoelectric actuators, which are integrated into the cold tuning system and used to compensate the small mechanical deformations of the cavity wall induced by Lorentz forces due to the high electromagnetic surface field, may be located in the radiation environment during particle accelerator operation. In order to provide for a reliable operation of the accelerator, the performance and life time of piezoelectric actuators (∼24.000 units for ILC) should not show any significant degradation for long periods (i.e. machine life duration: ∼20 years), even when subjected to intense radiation (i.e. gamma rays and fast neutrons). An experimental program, aimed at investigating the effect of fast neutrons radiation on the characteristics of piezoelectric actuators at liquid helium temperature (i.e. T∼4.2 K), was proposed for the working package WPNo.8 devoted to tuners development in the frame of CARE project. A neutrons irradiation facility, already installed at the CERI cyclotron located at Orleans (France), was upgraded and adapted for actuators irradiations tests purpose. A deuterons beam (maximum energy and beam current: 25 MeV and 35μA) collides with a thin (thickness: 3 mm) beryllium target producing a high neutrons flux with low gamma dose (∼20%): a neutrons fluence of more than 10 14 n/cm 2 is achieved in ∼20 hours of exposure. A dedicated cryostat was developed at IPN Orsay and used previously for radiation hardness test of calibrated cryogenic thermometers and pressure transducers used in LHC superconducting magnets. This cryostat could be operated either with liquid helium or liquid argon. This irradiation facility was upgraded for allowing fast turn-over of experiments and a dedicated experimental set-up was designed, fabricated, installed at CERI and successfully operated for radiation hardness tests of several piezoelectric actuators at T∼4.2 K. This new apparatus allows on-line automatic measurements of actuators characteristics and the

  19. Bread-Board Testing of the Radiation Hard Electron Monitor (RADEM) being developed for the ESA JUICE Mission

    Science.gov (United States)

    Mrigakshi, Alankrita; Hajdas, Wojtek; Marcinkowski, Radoslaw; Xiao, Hualin; Goncalves, Patricia; Pinto, Marco; Pinto, Costa; Marques, Arlindo; Meier, Dirk

    2016-04-01

    The RADEM instrument will serve as the radiation monitor for the JUICE spacecraft. It will characterize the highly dynamic radiation environment of the Jovian system by measuring the energy spectra of energetic electrons and protons up to 40 MeV and 250 MeV, respectively. It will also determine the directionality of 0.3-10 MeV electrons. Further goals include the detection of heavy ions, and the determination of the corresponding LET spectra and dose rates. Here, the tests of the Electron and Proton Telescopes, and the Directionality Detector of the RADEM Bread-Board model are described. The objective of these tests is to validate RADEM design and physical concept applied therein. The tests were performed at various irradiation facilities at the Paul Scherrer Institute (PSI) where energy ranges relevant for space applications can be covered (electrons: ≤100 MeV and protons: ≤230 MeV). The measured values are also compared with GEANT4 Monte-Carlo Simulation results.

  20. Development and Testing of a Shape Memory Alloy-Driven Composite Morphing Radiator

    Science.gov (United States)

    Walgren, P.; Bertagne, C.; Wescott, M.; Benafan, O.; Erickson, L.; Whitcomb, J.; Hartl, D.

    2018-01-01

    Future crewed deep space missions will require thermal control systems that can accommodate larger fluctuations in temperature and heat rejection loads than current designs. To maintain the crew cabin at habitable temperatures throughout the entire mission profile, radiators will be required to exhibit turndown ratios (defined as the ratio between the maximum and minimum heat rejection rates) as high as 12:1. Potential solutions to increase radiator turndown ratios include designs that vary the heat rejection rate by changing shape, hence changing the rate of radiation to space. Shape memory alloys exhibit thermally driven phase transformations and thus can be used for both the control and actuation of such a morphing radiator with a single active structural component that transduces thermal energy into motion. This work focuses on designing a high-performance composite radiator panel and investigating the behavior of various SMA actuators in this application. Three designs were fabricated and subsequently tested in a relevant thermal vacuum environment; all three exhibited repeatable morphing behavior, and it is shown through validated computational analysis that the morphing radiator concept can achieve a turndown ratio of 27:1 with a number of simple configuration changes.

  1. Development and Testing of a Shape Memory Alloy-Driven Composite Morphing Radiator

    Science.gov (United States)

    Walgren, P.; Bertagne, C.; Wescott, M.; Benafan, O.; Erickson, L.; Whitcomb, J.; Hartl, D.

    2018-03-01

    Future crewed deep space missions will require thermal control systems that can accommodate larger fluctuations in temperature and heat rejection loads than current designs. To maintain the crew cabin at habitable temperatures throughout the entire mission profile, radiators will be required to exhibit turndown ratios (defined as the ratio between the maximum and minimum heat rejection rates) as high as 12:1. Potential solutions to increase radiator turndown ratios include designs that vary the heat rejection rate by changing shape, hence changing the rate of radiation to space. Shape memory alloys exhibit thermally driven phase transformations and thus can be used for both the control and actuation of such a morphing radiator with a single active structural component that transduces thermal energy into motion. This work focuses on designing a high-performance composite radiator panel and investigating the behavior of various SMA actuators in this application. Three designs were fabricated and subsequently tested in a relevant thermal vacuum environment; all three exhibited repeatable morphing behavior, and it is shown through validated computational analysis that the morphing radiator concept can achieve a turndown ratio of 27:1 with a number of simple configuration changes.

  2. Final toxicity results of a radiation-dose escalation study in patients with non-small-cell lung cancer (NSCLC): Predictors for radiation pneumonitis and fibrosis

    International Nuclear Information System (INIS)

    Kong, F.-M.; Hayman, James A.; Griffith, Kent A.; Kalemkerian, Gregory P.; Arenberg, Douglas; Lyons, Susan; Turrisi, Andrew; Lichter, Allen; Fraass, Benedick; Eisbruch, Avraham; Lawrence, Theodore S.; Haken, Randall K. ten

    2006-01-01

    Purpose: We aimed to report the final toxicity results on a radiation-dose escalation trial designed to test a hypothesis that very high doses of radiation could be safely administered to patients with non-small-cell lung cancer (NSCLC) by quantifying the dose-volume toxicity relationship of the lung. Methods and Materials: A total of 109 patients with unresectable or medically inoperable NSCLC were enrolled and treated with radiation-dose escalation (on the basis of predicted normal-lung toxicity) either alone or with neoadjuvant chemotherapy by use of 3D conformal techniques. Eighty-four patients (77%) received more than 69 Gy, the trial was stopped after the dose reached 103 Gy. Estimated median follow-up was 110 months. Results: There were 17 (14.6%) Grade 2 to 3 pneumonitis and 15 (13.8%) Grade 2 to 3 fibrosis and no Grade 4 to 5 lung toxicity. Multivariate analyses showed them to be (1) not associated with the dose prescribed to the tumor, and (2) significantly (p < 0.001) associated with lung-dosimetric parameters such as the mean lung dose (MLD), volume of lung that received at least 20 Gy (V20), and the normal-tissue complication probability (NTCP) of the lung. If cutoffs are 30% for V20, 20 Gy for MLD, and 10% for NTCP, these factors have positive predictive values of 50% to 71% and negative predictive value of 85% to 89%. Conclusions: With long-term follow-up for toxicity, we have demonstrated that much higher doses of radiation than are traditionally administered can be safely delivered to a majority of patients with NSCLC. Quantitative lung dose-volume toxicity-based dose escalation can form the basis for individualized high-dose radiation treatment to maximize the therapeutic ratio in these patients

  3. Tamsulosin palliates radiation-induced urethritis in patients with prostate cancer: results of a pilot study

    International Nuclear Information System (INIS)

    Prosnitz, Robert G.; Schneider, Lindsey; Manola, Judy; Rocha, Sean; Loffredo, Marian; Lopes, Lynn; D'Amico, Anthony V.

    1999-01-01

    Purpose: A pilot study was performed to determine the effectiveness of Flomax (tamsulosin HCl) in the management of acute radiation urethritis in prostate cancer patients undergoing conformal external beam radiation therapy (RT). Potential predictors of response to Flomax were evaluated. Methods and Materials: From January 1998 to April 1998, 26 consecutive patients who developed symptoms of radiation urethritis while undergoing RT for prostate cancer were treated with Flomax, a superselective α 1A -adrenergic antagonist. A genitourinary review of systems served as the instrument used to assess baseline urinary function and treatment response. Results: The initial response rate to Flomax was 62% (16/26) at the 0.4 mg level and 60% (6/10) at the 0.8 mg level. Half of the 16 patients who initially responded to 0.4 mg subsequently progressed. Three-fourths of those patients who progressed, however, achieved a durable response with the 0.8 mg dose. Therefore urinary symptoms were ultimately controlled in 77% (20/26) of the patients. After correcting for the testing of multiple hypotheses (n = 5), the presence of benign prostatic hyperplasia (BPH) approached statistical significance for predicting the initial response to the 0.4 mg dose of Flomax (78% vs. 25%, p = 0.03). Conclusion: Flomax appears to be effective in relieving the symptoms of radiation urethritis. A Phase II trial is justified and in progress

  4. Pulsar timing arrays and gravity tests in the radiative regime

    Science.gov (United States)

    Lee, K. J.

    2013-11-01

    In this paper, we focus on testing gravity theories in the radiative regime using pulsar timing array observations. After reviewing current techniques to measure the dispersion and alternative polarization of gravitational waves, we extend the framework to the most general situations, where the combinations of a massive graviton and alternative polarization modes are considered. The atlas of the Hellings-Downs functions is completed by the new calculations for these dispersive alternative polarization modes. We find that each mode and corresponding graviton mass introduce characteristic features in the Hellings-Downs function. Thus, in principal, we can not only detect each polarization mode, measure the corresponding graviton mass, but also discriminate the different scenarios. In this way, we can test gravity theories in the radiative regime in a generalized fashion, and such method is a direct experiment, where one can address the gauge symmetry of the gravity theories in their linearized limits. Although current pulsar timing still lacks enough stable pulsars and sensitivity for such practices, we expect that future telescopes with larger collecting areas could make such experiments feasible.

  5. The morphological changes of adult mouse testes after 60Co Gamma-radiation

    International Nuclear Information System (INIS)

    Koruji, M.; Movahedin, M.; Gourabi, H.; Jabbary Arfaee, A.

    2008-01-01

    Cytotoxic therapy can lead to prolonged azoospermia or even sterility. In the present study, we investigated the morphological changes of mouse testes after γ-Radiation. Methods: After anesthetizing of NMRI mice, testes and their surrounding tissues were irradiated using a cobalt therapy machine. Four experimental groups were irradiated with fractionated doses of: 1.5+8, 1.5+12 and 1.5+16 Gy (with an interval of 24 h) and single dose of 14 Gy. Non-irradiated mice were considered as control group. Testes were removed 4, 6 and 8 weeks following irradiation, weighed and processed for light microscopic study. Diameters of seminiferous tubules and their lumens, epithelium thickness, percentage of different types of tubules and number of spermatogenic cell were measured. Moreover, sperm count motility and viability rates were evaluated in epididymis. Results: Number of normal tubules, epithelium thickness, tubules diameter and lumen diameter were significantly reduced with high dose irradiation in comparison with control testes. The recovery was observed after 8 weeks. Epididymal sperm count, motility and viability rates were significantly decreased in the irradiated mice comparing non-irradiated ones. These parameters were increased after 8 weeks. Conclusion: According to the results, irradiation can cause temporary azoospermia in mouse and this effect is reversible after 8 weeks

  6. Performance test of SKIROC II ASIC chip for the radiation detection

    Energy Technology Data Exchange (ETDEWEB)

    Jun, W. J.; Namgoong, H.; Kim, B. K.; Song, H. S.; Kim, H. S.; Lee, S. H.; Choi, H. J.; Ghergherehchi, M.; Chai, J. S. [Sungkyunkwan University, Suwon (Korea, Republic of)

    2017-04-15

    There is a PCB board called FEV8 board which can readout analog signal from any energy source, and amplify it for signal processing. For precise detection, the board had been designed to operate in wide range of energy condition, with high-resolutive detection performance. This function has the possibility of the utilization for the radiation detection. The channels of the prototype board must be evaluated to make sure that the board is perfect or not. This research had made an progress for the radiation detection as well as the electronics of the intricate combination of the measurement instrumentations. The number of the noisy channels had been measured for threshold scan, and every channels in the board had been evaluated. By improving the experimental conditions such as test script in Linux system or well designed ground condition of the test bench, much more clean data will be able to be acquisited.

  7. Accelerated aging tests of radiation damaged lasers and photodiodes for the CMS tracker optical links

    CERN Document Server

    Gill, K; Batten, J; Cervelli, G; Grabit, R; Jensen, F; Troska, Jan K; Vasey, F

    1999-01-01

    The combined effects of radiation damage and accelerated ageing in COTS lasers and p-i-n photodiodes are presented. Large numbers of these devices are employed in future High Energy Physics experiments and it is vital that these devices are confirmed to be sufficiently robust in terms of both radiation resistance and reliability. Forty 1310 nm InGaAsP edge-emitting lasers (20 irradiated) and 30 InGaAs p- i-n photodiodes (19 irradiated) were aged for 4000 hours at 80 degrees C with periodic measurements made of laser threshold and efficiency, in addition to p-i-n leakage current and photocurrent. There were no sudden failures and there was very little wearout- related degradation in either unirradiated or irradiated sample groups. The results suggest that the tested devices have a sufficiently long lifetime to operate for at least 10 years inside the Compact Muon Solenoid experiment despite being exposed to a harsh radiation environment. (13 refs).

  8. Valve stem packing seal test results for primary heat transport system conditions in Canadian nuclear generating stations

    International Nuclear Information System (INIS)

    Dixon, D.F.; Farrell, J.M.; Coutinho, R.F.

    1978-06-01

    Valve stem packing tests were done to obtain performance data on packing already in CANDU-PHW reactor service and on alternative packings. Most of the tests were replicated. Results are presented for ten packings tested under two stem cycle modes; leakage, packing consolidation and packing friction were the main responses. Packing tests were performed with water at close to CANDU-PHW reactor primary heat transport (PHT) system conditions (288 deg C and 10 MPa), but without ionizing radiation. The test rigs had rising, rotating stems. Stuffing box dimensions were typical of a standard Velan valve; packings were spring loaded to control applied packing stress

  9. Influence of ionizing radiation on the catalytic properties of oxide catalysts tested by hydrogen peroxide decomposition

    International Nuclear Information System (INIS)

    Mucka, V.

    1987-01-01

    Results of a study of some physical and catalytic properties of different oxide catalysts as affected by ionizing radiation (γ, n, e - ) and tested by the decomposition of hydrogen peroxide in aqueous solution are presented in this paper. The oxidation state of the active component present on the catalyst surface was found to be one of the most sensitive properties to the ionizing radiation. Changes of this state induced by γ-irradiation were found to be positive in most cases; electron pre-irradiation of the oxides leads, as a rule, to negative effects and the effects of neutron irradiation may be positive or negative. On the other hand, changes in the catalytic activity of the oxides after γ-or electron-irradiation seem to be mostly negative and positive, respectively; the effects of fast neutrons seem to vary here. Neither quantitative or qualitative correlation was found between the radiation-induced changes in these two quantities. The results give evidence that ionizing radiation principally affects the surface concentration of the catalytic sites. Both the character and magnitude of the changes in surface oxidation abilities and in catalytic activities of the oxide catalysts seem to be dependent upon the actual state of the catalyst surface. (author)

  10. Health survey of radiation workers. Results of questionnaire

    International Nuclear Information System (INIS)

    Morikawa, Kaoru; Aoyama, Takashi; Kawagoe, Yasumitsu; Sunayashiki, Tadashi; Tanaka, Kiyoshi; Nishitani, Motohiro; Yoshinaga, Nobuharu

    1998-01-01

    The Japanese Society of Radiological Technology asked radiation workers about the radiation doses and the state of their health as well as family. The reports by the Health and Welfare Ministry were referenced to compare radiation workers with others. The questionnaire was sent to about 4,000 members, and returned from 2,479. The survey showed that 684 persons (27.6%) felt health anxiety, 455 persons (18.4%) had medical check for recent one year, and 1,645 persons (66.4%) had anamnesis. Radiation doses for one year and cumulated doses varied according to engaging duration. (K.H.)

  11. [Results of a cytogenetic study of populations with different radiation risks in the Semipalatinsk region].

    Science.gov (United States)

    Sviatova, G S; Abil'dinova, G Z; Berezina, G M

    2002-03-01

    A cytogenetic study was conducted for the first time on human populations neighboring the Semipalatinsk nuclear test site (STS) and exposed to ionizing radiation for a long period of time. In populations with the extreme and maximum radiation risks, high frequencies of radiation-induced chromosomal markers, including acentric fragments (1.99 +/- 0.10 per 100 cells), dicentrics (0.23 +/- 0.01), ring chromosomes (0.38 +/- 0.14), and stable chromosomal aberrations (1.17 +/- 0.02), were found. These frequencies significantly exceeded those in control populations. The spectrum of chromosomal aberrations and the frequencies of the aberrations of different types in persons living in the areas with the highest radionuclide contamination confirmed the mutagenic effect of radiation on chromosomes in the human populations studied.

  12. Topical issues of radiographic testing and radiation protection. Papers

    International Nuclear Information System (INIS)

    1992-01-01

    The seven papers demonstrate current developments in radiation protection. The amendment of the Radiation Protection Ordinance and the new Ordinance on the Transport of Hazardous Goods by Road were discussed in particular. A major results of the discussion meeting was the foundation of the working group on 'Transport of radioactive substances'. In terms of radiographic practive, the authors addressed European standardization, instruments and technology in radioscopy, and computer-aided image processing. (orig./HP) [de

  13. Preliminary Results on Design and Implementation of a Solar Radiation Monitoring System

    Directory of Open Access Journals (Sweden)

    Lorentz Jäntschi

    2008-02-01

    Full Text Available The paper presents a solar radiation monitoring system, using two scientificpyranometers and an on-line computer home-made data acquisition system. The firstpyranometer measures the global solar radiation and the other one, which is shaded,measure the diffuse radiation. The values of total and diffuse solar radiation arecontinuously stored into a database on a server. Original software was created for dataacquisition and interrogation of the created system. The server application acquires the datafrom pyranometers and stores it into a database with a baud rate of one record at 50seconds. The client-server application queries the database and provides descriptivestatistics. A web interface allow to any user to define the including criteria and to obtainthe results. In terms of results, the system is able to provide direct, diffuse and totalradiation intensities as time series. Our client-server application computes also derivateheats. The ability of the system to evaluate the local solar energy potential is highlighted.

  14. The results of palliative radiation therapy in patients with unresectable advanced pancreatic cancer

    International Nuclear Information System (INIS)

    Ryu, Mi Ryeong; Yoon, Sei Chul; Kim, Yeon Sil; Chung, Su Mi

    2006-01-01

    To evaluate the treatment results and prognostic factors of palliative radiation therapy in the patients with unresectable advanced pancreatic cancer. Thirty-seven evaluable patients with unresectable advanced pancreatic cancer who were treated by palliative radiation therapy for pain relief at the Department of Radiation Oncology, Kangnam St. Mary's hospital, the Catholic University of Korea between March 1984 and February 2005 were analysed retrospectively. There were 22 men and 15 women. Age at diagnosis ranged from 30 to 80 (median 57) years. Twelve patients (32.4%) had liver metastases and 22 patients (59.5%) had lymph node metastases. Radiation therapy was delivered to primary tumor and regional lymph nodes with 1 ∼ 2 cm margin, and total dose was 3,240 ∼ 5,580 cGy (median 5,040 cGy). Chemotherapy with radiotherapy was delivered in 30 patients (81%) with 5-FU alone (21 patients) or gemcitabine (9 patients). The follow-up period ranged from 1 to 44 months. Survival and prognostic factors were analysed using Kaplan-Meier method and log-rank test respectively. Overall mean and median survival were 11 and 8 months and 1-year survival rate was 20%. Among 33 patients who were amenable for response evaluation, 7 patients had good response and 22 patients had fail response with overall response rate of 87.9%. Mild to moderate toxicity were observed in 14 patients with nausea, vomiting, and indigestion, but severe toxicity requiring interruption of treatment were not observed. Chemotherapy didn't influence the survival and symptomatic palliation, but the group containing gemcitabine showed a tendency of longer survival (median 12 months) than 5-FU alone group (median 5.5 months) without statistical significance (ρ > 0.05). The significant prognostic factors were Karnofsky performance status and liver metastasis (ρ 0.05). Radiation therapy was effective for symptomatic palliation in the patients with unresectable advanced pancreatic cancer and would play an

  15. Comparison of rate theory based modeling calculations with the surveillance test results of Korean light water reactors

    International Nuclear Information System (INIS)

    Lee, Gyeong Geun; Lee, Yong Bok; Kim, Min Chul; Kwon, Junh Yun

    2012-01-01

    Neutron irradiation to reactor pressure vessel (RPV) steels causes a decrease in fracture toughness and an increase in yield strength while in service. It is generally accepted that the growth of point defect cluster (PDC) and copper rich precipitate (CRP) affects radiation hardening of RPV steels. A number of models have been proposed to account for the embrittlement of RPV steels. The rate theory based modeling mathematically described the evolution of radiation induced microstructures of ferritic steels under neutron irradiation. In this work, we compared the rate theory based modeling calculation with the surveillance test results of Korean Light Water Reactors (LWRs)

  16. Radiation hardening and irradiation testing of in-cell electronics for MA23/APM

    International Nuclear Information System (INIS)

    Friant, A.

    1988-09-01

    We relate briefly the radiation hardening method used to guarantee a gamma resistance of 10 Mrad for the whole electronic equipment associated with the slave arm of MA23 M servomanipulator which will be set up in cell 404 in Marcoule (APM). We describe the radiation testing of electronic devices and of the various subsystems designed by the D. LETI groups involved in the MA23/APM project

  17. Radiation Effects and Component Hardening testing program at the Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Draper, J.V.; Weil, B.S.; Chesser, J.B.

    1993-01-01

    This paper describes Phase II of the Radiation Effects and Component Hardening (REACH) testing program, performed as part of the joint collaborative agreement between the United States Department of Energy (USDOE) and the Power Reactor and Nuclear Fuel Development Corporation (PNC) of Japan, Components and materials were submitted to 10 5 R/hr gamma radiation fields for 10,000 hr, producing accumulated doses of 10 9 R; most performed as expected

  18. Summary test results of the particle-beam diagnostics for the Advanced Photon Source (APS) subsystems

    International Nuclear Information System (INIS)

    Lumpkin, A.; Wang, X.; Sellyey, W.; Patterson, D.; Kahana, E.

    1994-01-01

    During the first half of 1994, a number of the diagnostic systems for measurement of the charged-particle beam parameters throughout the subsystems of the Advanced Photon Source (APS) have been installed and tested. The particle beams eventually will involve 450-MeV to 7-GeV positrons and with different pulse formats. The first test and commissionin results for beam profiles, beam position monitors, loss rate monitors, current monitors, and synchrotron radiation photon monitors hve been obtained using 200- to 350-MeV electron beams injected into the subsystems. Data presented are principally from the transport lines and the positron accumulator ring

  19. Measurement protocols for performance testing of dosimetry services for external radiations

    International Nuclear Information System (INIS)

    1993-01-01

    In the Health and Safety Executive's ''Requirements for the Approval of Dosimetry Services under the Ionising Radiations Regulations 1985'', it is stipulated that dosimetry services seeking approval must show that they have successfully completed a performance test. The services must arrange for the tests to be carried out on application and thereafter every 18 months, by a laboratory which has received accreditation from the National Measurement Accreditation Service (NAMAS) for the whole performance testing activity. The performance tests must be carried out to published protocols and the purpose here is to provide protocols for external, whole body film and TLD dosimetry services, and for skin and extremity dosimetry services. (Author)

  20. Results of the Association of Directors of Radiation Oncology Programs (ADROP) Survey of Radiation Oncology Residency Program Directors

    International Nuclear Information System (INIS)

    Harris, Eleanor; Abdel-Wahab, May; Spangler, Ann E.; Lawton, Colleen A.; Amdur, Robert J.

    2009-01-01

    Purpose: To survey the radiation oncology residency program directors on the topics of departmental and institutional support systems, residency program structure, Accreditation Council for Graduate Medical Education (ACGME) requirements, and challenges as program director. Methods: A survey was developed and distributed by the leadership of the Association of Directors of Radiation Oncology Programs to all radiation oncology program directors. Summary statistics, medians, and ranges were collated from responses. Results: Radiation oncology program directors had implemented all current required aspects of the ACGME Outcome Project into their training curriculum. Didactic curricula were similar across programs nationally, but research requirements and resources varied widely. Program directors responded that implementation of the ACGME Outcome Project and the external review process were among their greatest challenges. Protected time was the top priority for program directors. Conclusions: The Association of Directors of Radiation Oncology Programs recommends that all radiation oncology program directors have protected time and an administrative stipend to support their important administrative and educational role. Departments and institutions should provide adequate and equitable resources to the program directors and residents to meet increasingly demanding training program requirements.

  1. Overview of a benefit/risk ratio optimized for a radiation emitting device used in non-destructive testing

    Energy Technology Data Exchange (ETDEWEB)

    Maharaj, H.P., E-mail: H_P_Maharaj@hc-sc.gc.ca [Health Canada, Dept. of Health, Consumer and Clinical Radiaton Protection Bureau, Ottawa, Ontario (Canada)

    2016-03-15

    This paper aims to provide an overview of an optimized benefit/risk ratio for a radiation emitting device. The device, which is portable, hand-held, and open-beam x-ray tube based, is utilized by a wide variety of industries for purposes of determining elemental or chemical analyses of materials in-situ based on fluorescent x-rays. These analyses do not cause damage or permanent alteration of the test materials and are considered a non-destructive test (NDT). Briefly, the key characteristics, principles of use and radiation hazards associated with the Hay device are presented and discussed. In view of the potential radiation risks, a long term strategy that incorporates risk factors and guiding principles intended to mitigate the radiation risks to the end user was considered and applied. Consequently, an operator certification program was developed on the basis of an International Standards Organization (ISO) standard (ISO 20807:2004) and in collaboration with various stake holders and was implemented by a federal national NDT certification body several years ago. It comprises a written radiation safety examination and hands-on training with the x-ray device. The operator certification program was recently revised and the changes appear beneficial. There is a fivefold increase in operator certification (Levels 1 a nd 2) to date compared with earlier years. Results are favorable and promising. An operational guidance document is available to help mitigate radiation risks. Operator certification in conjunction with the use of the operational guidance document is prudent, and is recommended for end users of the x-ray device. Manufacturers and owners of the x-ray devices will also benefit from the operational guidance document. (author)

  2. Overview of a benefit/risk ratio optimized for a radiation emitting device used in non-destructive testing

    International Nuclear Information System (INIS)

    Maharaj, H.P.

    2016-01-01

    This paper aims to provide an overview of an optimized benefit/risk ratio for a radiation emitting device. The device, which is portable, hand-held, and open-beam x-ray tube based, is utilized by a wide variety of industries for purposes of determining elemental or chemical analyses of materials in-situ based on fluorescent x-rays. These analyses do not cause damage or permanent alteration of the test materials and are considered a non-destructive test (NDT). Briefly, the key characteristics, principles of use and radiation hazards associated with the Hay device are presented and discussed. In view of the potential radiation risks, a long term strategy that incorporates risk factors and guiding principles intended to mitigate the radiation risks to the end user was considered and applied. Consequently, an operator certification program was developed on the basis of an International Standards Organization (ISO) standard (ISO 20807:2004) and in collaboration with various stake holders and was implemented by a federal national NDT certification body several years ago. It comprises a written radiation safety examination and hands-on training with the x-ray device. The operator certification program was recently revised and the changes appear beneficial. There is a fivefold increase in operator certification (Levels 1 a nd 2) to date compared with earlier years. Results are favorable and promising. An operational guidance document is available to help mitigate radiation risks. Operator certification in conjunction with the use of the operational guidance document is prudent, and is recommended for end users of the x-ray device. Manufacturers and owners of the x-ray devices will also benefit from the operational guidance document. (author)

  3. Irradiation effects test Series Scoping Test 1: test results report

    International Nuclear Information System (INIS)

    Quapp, W.J.; Allison, C.M.; Farrar, L.C.

    1977-09-01

    The report describes the results of the first scoping test in the Irradiation Effects Test Series conducted by the Thermal Fuels Behavior Program, which is part of the Water Reactor Research Program of EG and G Idaho, Inc. The research is sponsored by the United States Nuclear Regulatory Commission. This test used an unirradiated, three-foot-long, PWR-type fuel rod. The objective of this test was to thoroughly evaluate the remote fabrication procedures to be used for irradiated rods in future tests, handling plans, and reactor operations. Additionally, selected fuel behavior data were obtained. The fuel rod was subjected to a series of preconditioning power cycles followed by a power increase which brought the fuel rod power to about 20.4 kW/ft peak linear heat rating at a coolant mass flux of 1.83 x 10 6 lb/hr-ft 2 . Film boiling occurred for a period of 4.8 minutes following flow reductions to 9.6 x 10 5 and 7.5 x 10 5 lb/hr-ft 2 . The test fuel rod failed following reactor shutdown as a result of heavy internal and external cladding oxidation and embrittlement which occurred during the film boiling operation

  4. Result of radiation therapy for inoperable pancreas cancer

    International Nuclear Information System (INIS)

    Okawa, Tomohiko; Ikeda, Michio; Tazaki, Eisei; Kaneda, Koichi; Tsuya, Akira.

    1978-01-01

    Twenty cases of the pancreas cancer were treated by means of 60 Co γ or Linac x-rays during the period between 1958 and 1977 at the Cancer Institute Hospital and Tokyo Women's Medical College. 11 were irradiated by external radiation and 9 by intraoperative radiation. Pancreas irradiation was indicated for relief of pain and alleviation of jaundice although the effect was symptomatic. 2500 rad of intraoperative radiation was reasonable dose in about 10 x 10 cm radiation field. Radical curative irradiation for pancreas cancer might be rarely indicated. Radiotherapy of pancreas cancer should be considered in conjunction with multimodal treatment in the future. (author)

  5. Design of a synchrotron radiation detector for the test beam lines at the Superconducting Super Collider Laboratory

    International Nuclear Information System (INIS)

    Hutton, R.D.

    1994-01-01

    As part of the particle- and momentum-tagging instrumentation required for the test beam lines of the Superconducting Super Collider (SSC), the synchrotron radiation detector (SRD) was designed to provide electron tagging at momentum above 75 GeV. In a parallel effort to the three test beam lines at the SSC, schedule demands required testing and calibration operations to be initiated at Fermilab. Synchrotron radiation detectors also were to be installed in the NM and MW beam lines at Femilab before the test beam lines at the SSC would become operational. The SRD is the last instrument in a series of three used in the SSC test beam fines. It follows a 20-m drift section of beam tube downstream of the last silicon strip detector. A bending dipole just in of the last silicon strip detector produces the synchrotron radiation that is detected in a 50-mm-square cross section NaI crystal. A secondary scintillator made of Bicron BC-400 plastic is used to discriminate whether it is synchrotron radiation or a stray particle that causes the triggering of the NaI crystal's photo multiplier tube (PMT)

  6. Report of questionnaire result concerning the radiation control in medicare facilities

    International Nuclear Information System (INIS)

    Nakamura, Yutaka

    2009-01-01

    Radiation control in Japanese medicare facilities is regulated generally by multiple laws of radiation and the Committee has investigated their actual radiation control practice through questionnaire, of which result and its analysis are described here. The questionnaire on web (Committee's homepage) was conducted in the period Apr., 13-May, 1, 2009, by asking to medical radiology personnel (MRP) with 20 items, mainly about personnel working for radiation medicare (RM), monitoring of their external dose, notice of exposure dose to individual person, archiving of the dose record, and questions about the Law Concerning Prevention from Radiation Hazard due to Radioisotopes, Etc.; was answered by 378 facilities where 15,281 persons in total worked for RM (41/facility in average); and the facilities were under regulation by 1 (Medical, 39%) and 2 (Medical and for Prevention, 61%) laws. Major findings were: 71% of facilities had no clear rule to select MRP; 98% trusted dosimetry outside; in 76%, personnel participating in RM had pocket dosimeter as well; 70% investigated the exposure history at personnel employment; to personnel whose dose could exceed or exceeded 20 mSv/y, 45% transferred the person to other work site, 34% issued warning and 21% had no such personnel; 73% felt the necessity of qualified expert for radiation control; 81% conducted education and training to MRP; 54% used radiation-generating equipments, 27%, unsealed radioisotopes and 19%, sealed ones; and 77% felt the radiation control should be unified in the Medical Law. Based on the findings, the Committee discussed and commented about definition and selection of MRP, dosimetry and its record of MRP having multiple, increasing works, uncertainty of the exact number of MRP in Japan, and desirable unification of radiation control practice in the medicare facility into the Medical Law if amended in future. (K.T.)

  7. Sucralfate for radiation mucositis: results of a double-blind randomized trial

    International Nuclear Information System (INIS)

    Meredith, Ruby; Salter, Merle; Kim, Robert; Spencer, Sharon; Weppelmann, Burkhard; Rodu, Brad; Smith, Judy; Lee, Jeanette

    1997-01-01

    Purpose: To determine if addition of the ulcer-coating polysaccharide sucralfate could improve symptomatic relief of radiation mucositis over a popular combination of antacid, diphenhydramine, and viscous lidocaine alone. Methods and Materials: A double-blind study was conducted in which nurses and pharmacists coded patient groups and distributed medication in a manner blinded to both the patients and physicians. Eligible patients receiving radiation to the head and neck and/or chest sites that included the esophagus were randomized to a standard combination of antacid, diphenhydramine, and viscous lidocaine vs. the same solution plus sucralfate. Eligible patients were those receiving >40 Gy at 1.8 Gy/fraction, one fraction/day, five fractions/week. Participating patients were stratified between chest, small field head and neck, and large field head and neck. The observations and smears for Candidiasis screening. Medication was prescribed when the patient became symptomatic and concomitant use of other locally effective nonstudy agents was not allowed. The ability to eat various consistency of foods was graded 0-5, with 5 indicating no compromise of ability to ingest a food compared to baseline. Statistical analysis included mean + SD for food and soreness scores, paired t-test, and two-way analyses of variance to evaluate effects of site and treatment group on the changes in scores. Results: Over 2 years, 111 patients were entered. Because some withdrew and others did not require medication, results are presented for evaluable patients in each category. Mild adverse effects from the medication solution (usually mouth discomfort) were reported by <10% of patients in each treatment group among 106 patients evaluable for toxicity. There was a comparable incidence of mild-moderate mucositis for the two treatment groups. Severe mucositis was noted in two patients of the standard medication group and none among patients receiving sucralfate. The groups were comparable

  8. Irradiation effects test series, test IE-5. Test results report

    International Nuclear Information System (INIS)

    Croucher, D.W.; Yackle, T.R.; Allison, C.M.; Ploger, S.A.

    1978-01-01

    Test IE-5, conducted in the Power Burst Facility at the Idaho National Engineering Laboratory, employed three 0.97-m long pressurized water reactor type fuel rods, fabricated from previously irradiated zircaloy-4 cladding and one similar rod fabricated from unirradiated cladding. The objectives of the test were to evaluate the influence of simulated fission products, cladding irradiation damage, and fuel rod internal pressure on pellet-cladding interaction during a power ramp and on fuel rod behavior during film boiling operation. The four rods were subjected to a preconditioning period, a power ramp to an average fuel rod peak power of 65 kW/m, and steady state operation for one hour at a coolant mass flux of 4880 kg/s-m 2 for each rod. After a flow reduction to 1800 kg/s-m 2 , film boiling occurred on one rod. Additional flow reductions to 970 kg/s-m 2 produced film boiling on the three remaining fuel rods. Maximum time in film boiling was 80s. The rod having the highest initial internal pressure (8.3 MPa) failed 10s after the onset of film boiling. A second rod failed about 90s after reactor shutdown. The report contains a description of the experiment, the test conduct, test results, and results from the preliminary postirradiation examination. Calculations using a transient fuel rod behavior code are compared with the test results

  9. Mometasone Furoate Cream Reduces Acute Radiation Dermatitis in Patients Receiving Breast Radiation Therapy: Results of a Randomized Trial

    International Nuclear Information System (INIS)

    Hindley, Andrew; Zain, Zakiyah; Wood, Lisa; Whitehead, Anne; Sanneh, Alison; Barber, David; Hornsby, Ruth

    2014-01-01

    Purpose: We wanted to confirm the benefit of mometasone furoate (MF) in preventing acute radiation reactions, as shown in a previous study (Boström et al, Radiother Oncol 2001;59:257-265). Methods and Materials: The study was a double-blind comparison of MF with D (Diprobase), administered daily from the start of radiation therapy for 5 weeks in patients receiving breast radiation therapy, 40 Gy in 2.67-Gy fractions daily over 3 weeks. The primary endpoint was mean modified Radiation Therapy Oncology Group (RTOG) score. Results: Mean RTOG scores were significantly less for MF than for D (P=.046). Maximum RTOG and mean erythema scores were significantly less for MF than for D (P=.018 and P=.012, respectively). The Dermatology Life Quality Index (DLQI) score was significantly less for MF than for D at weeks 4 and 5 when corrected for Hospital Anxiety and Depression (HAD) questionnaire scores. Conclusions: MF cream significantly reduces radiation dermatitis when applied to the breast during and after radiation therapy. For the first time, we have shown a significantly beneficial effect on quality of life using a validated instrument (DLQI), for a topical steroid cream. We believe that application of this cream should be the standard of care where radiation dermatitis is expected

  10. Mometasone Furoate Cream Reduces Acute Radiation Dermatitis in Patients Receiving Breast Radiation Therapy: Results of a Randomized Trial

    Energy Technology Data Exchange (ETDEWEB)

    Hindley, Andrew, E-mail: andrew.hindley@lthtr.nhs.uk [Rosemere Cancer Centre, Royal Preston Hospital, Preston (United Kingdom); Zain, Zakiyah [College of Arts and Sciences, Universiti Utara Malaysia, Kedah (Malaysia); Wood, Lisa [Department of Social Sciences, Lancaster Medical School, Lancaster (United Kingdom); Whitehead, Anne [Medical and Pharmaceutical Statistics Research Unit, Lancaster University, Lancaster (United Kingdom); Sanneh, Alison; Barber, David; Hornsby, Ruth [Rosemere Cancer Centre, Royal Preston Hospital, Preston (United Kingdom)

    2014-11-15

    Purpose: We wanted to confirm the benefit of mometasone furoate (MF) in preventing acute radiation reactions, as shown in a previous study (Boström et al, Radiother Oncol 2001;59:257-265). Methods and Materials: The study was a double-blind comparison of MF with D (Diprobase), administered daily from the start of radiation therapy for 5 weeks in patients receiving breast radiation therapy, 40 Gy in 2.67-Gy fractions daily over 3 weeks. The primary endpoint was mean modified Radiation Therapy Oncology Group (RTOG) score. Results: Mean RTOG scores were significantly less for MF than for D (P=.046). Maximum RTOG and mean erythema scores were significantly less for MF than for D (P=.018 and P=.012, respectively). The Dermatology Life Quality Index (DLQI) score was significantly less for MF than for D at weeks 4 and 5 when corrected for Hospital Anxiety and Depression (HAD) questionnaire scores. Conclusions: MF cream significantly reduces radiation dermatitis when applied to the breast during and after radiation therapy. For the first time, we have shown a significantly beneficial effect on quality of life using a validated instrument (DLQI), for a topical steroid cream. We believe that application of this cream should be the standard of care where radiation dermatitis is expected.

  11. The Radiation Effect to Waste Glass that Resulting of Vitrification

    International Nuclear Information System (INIS)

    Herlan Martono; Aisyah

    2002-01-01

    The high level liquid waste (HLLW) is generated from the first step extraction of the nuclear fuel reprocessing. This waste was contain of few of actinide and many of fission product. The alpha radiation of actinide that contain on the HLLW cause the change the waste glass characteristic. The experiment was conducted by the doping, irradiation and heating of waste glass resulting from vitrification. The alpha radiation cause the change of composition that could be detected from change of waste glass density and mechanical strength. The increasing of alpha radiation dose cause the increasing change of density and mechanical strength, although the change of mechanical strength is not significant. Degree of change of waste glass density also depend on type of waste-glass and reach for saturated point at over of 5x10 24 alpha decay/m 3 . The gamma radiation of fission product that contain on the HLLW can increasing of waste glass temperature that cause the structure change, so devitrification was occur. The devitrification can the increasing of leaching rate. The cumulative of gamma dose rate was not cause the devitrification. (author)

  12. Study of radiation detectors response in standard X, gamma and beta radiation standard beams

    International Nuclear Information System (INIS)

    Nonato, Fernanda Beatrice Conceicao

    2010-01-01

    The response of 76 Geiger-Mueller detectors, 4 semiconductor detectors and 34 ionization chambers were studied. Many of them were calibrated with gamma radiation beams ( 37 Cs and 60 Co), and some of them were tested in beta radiation ( 90 Sr+ 9' 0Y e 204 Tl) and X radiation (N-60, N-80, N-100, N-150) beams. For all three types of radiation, the calibration factors of the instruments were obtained, and the energy and angular dependences were studied. For beta and gamma radiation, the angular dependence was studied for incident radiation angles of 0 deg and +- 45 deg. The curves of the response of the instruments were obtained over an angle interval of 0 deg to +- 90 deg, for gamma, beta and X radiations. The calibration factors obtained for beta radiation were compared to those obtained for gamma radiation. For gamma radiation, 24 of the 66 tested Geiger-Mueller detectors presented results for the energy dependence according to international recommendation of ISO 4037-2 and 56 were in accordance with the Brazilian ABNT 10011 recommendation. The ionization chambers and semiconductors were in accordance to national and international recommendations. All instruments showed angular dependence less than 40%. For beta radiation, the instruments showed unsatisfactory results for the energy dependence and angular dependence. For X radiation, the ionization chambers presented results for energy dependence according to the national recommendation, and the angular dependence was less than 40%. (author)

  13. The current state of radiation education in schools and results of the opinion survey on radiation

    International Nuclear Information System (INIS)

    Murai, Kenji

    2013-01-01

    In 2008, a new guideline about radioactivity was added to the government guidelines for teaching junior high school science. Since then people involved with school education have been trying to spread correct information about radioactivity. On the other hand, people's confusion in the aftermath of the Fukushima Daiichi Nuclear Power Plant accident has clearly shown that people do not know much about radioactivity. Considering the situation, the author conducted an investigation about the current state of radiation education and carried out an opinion survey about radioactivity among adults. The investigation about education showed the following: (1) the nature of radiation, such as its permeability, and its uses were described in the government-approved textbooks; (2) basic knowledge, such as what are radiation effects, were described comprehensively in the supplementary reading recommendations made by the Ministry of Education, Culture, Sports, Science, and Technology; and (3) locale education committees created teaching materials such as guidance to present topics. The opinion survey had questions to judge: (1) current public understanding of radioactivity; (2) the degree of general information that people collected for themselves; (3) the degree of specific knowledge about radioactivity that people had; and (4) people's attitudes toward various problems with radioactivity in the environment. The results suggested that for radiation education the following items are important: (1) to learn that radioactivity exists in people's daily lives and is used safely in various field; (2) to get basic knowledge and better quantitative understanding of such things as radioactivity units, radiation dose and radiation effects; and (3) to acquire practical experience to use the information effectively. (author)

  14. On-Line Radiation Test Facility for Industrial Equipment needed for the Large Hadron Collider at CERN

    CERN Document Server

    Rausch, R

    1999-01-01

    The future Large Hadron Collider to be built at CERN will use superconducting magnets cooled down to 1.2 K. To preserve the superconductivity, the energy deposition dose levels in equipment located outside the cryostat, in the LHC tunnel, are calculated to be of the order of 1 to 10 Gy per year. At such dose levels, no major radiation-damage problems are to be expected, and the possibility of installing Commercial Of The Shelf (COTS) electronic equipment in the LHC tunnel along the accelerator is considered. To this purpose, industrial electronic equipment and circuits have to be qualified and tested against radiation to insure their long term stability and reliability. An on-line radiation test facility has been setup at the CERN Super Proton Synchrotron (SPS) and a program of on-line tests for electronic equipment is ongoing. Equipment tested includes Industrial Programmable Logic Controllers (PLCs) from several manufacturers, standard VME modules, Fieldbuses like Profibus, WorldFIP and CAN, various electro...

  15. Radiation Control on Uzbekistan Borders - Results and Perspectives

    International Nuclear Information System (INIS)

    Petrenko, Vitaliy; Yuldashev, Bekhzod; Ismailov, Ulughbek; Shipilov, Nikolay; Chipizubov, Sergey; Avezov, Anvar

    2009-01-01

    The measures and actions on prevention, detection and response to criminal or unauthorized acts involving radioactive materials in Uzbekistan are presented. In frames of program of radiation monitoring to prevent illicit trafficking of nuclear and radioactive materials main customs border checkpoints were equipped with commercial radiation portal monitors. Special radiation monitors elaborated and manufactured in INP AS RU are installed in INP(main gates, research reactor and laboratory building) to provide nuclear security of Institute facilities. The experience of Uzbekistan in establishing radiation monitoring systems on its borders, their operation and maintenance would be useful for realization of proposed plan of strengthening measures to prevent illicit trafficking in Republics of Central Asia region.

  16. The effects of environmental factors and experimental method on the results of low dose rate microprocessor irradiation tests

    Energy Technology Data Exchange (ETDEWEB)

    Laviron, A; Gerard, G [Commissariat a l' Energie Atomique, IPSN, Centre d' Etudes de Valduc, Is-sur-Tille (France); Gauthier, G; Henry, J Y; Le Meur, M [Commissariat a l' Energie Atomique, IPSN, Fontenay-aux-Roses (France)

    1992-02-01

    As part of the safety studies of nuclear facilities, a series of experiments have been in progress over a number of years to determine the principal parameters for which allowance needs to be made in the testing of microprocessors in low dose rate nuclear irradiation environments. This paper contains a brief description of the results already published, followed by a review of the latest results obtained, specifically as concerns the effects of temperature, the origin of the batch, the angle of incidence of the radiation and the test routine used. (author)

  17. Development of radiation alarm monitor

    International Nuclear Information System (INIS)

    Myung Jae Song; Myung Chan Lee; Jung Kwan Son

    1997-01-01

    The Radiation Alarm Monitor is developed domestically in order to protect radiation workers from over exposure. The Radiation Alarm Monitor with microprocessor installed can record the information of radiation field before and after accidents. It can also provide the data to analyze the accident and to set a counterplan. It features a wide detection range of radiation (I OmR/h - I OOR/h), radiation work and data storage, portability, high precision (5%) due to calibration, and adaptation of a powerful alarm system. In order to protect workers from over exposure, light and sound alarm had been designed to initiate when accident occurs such as an unexpected change of radiation field such as radiation rate and accumulated dosed between 90 min. before the alarm and 30 min. after the alarm. In addition, the Radiation Alarm Monitor interfaces with computer so that the accident can be analyzed. After the testing conditions in other countries for the Radiation Alarm Monitor were compared, the most stringent test, ANSI N42. 17-A, was selected. The performance testing was car-ried out under various conditions of temperature, humidity, vibration and electromagnetic wave hindrance by Korea Research Institute of Standards and Science (KRISS). As a result, the Radiation Alan-n Monitor passed all test. Also, for the Radiation Alarm Monitor, environmental adaptability tests under the environmental conditions of NPP sites had been performed. The Radiation Alan-n Monitor had been reviewed by radiation workers at NPPs and their opinions had been collected. Operating procedure will be written and distributed to every NPP sites. Radiation Alarm Monitor will be modified for use under the specific environmental conditions of each site. It will be distributed to NPP sites and will be used by radiation workers

  18. LWR surveillance dosimetry improvement program: PSF metallurgical blind test results

    International Nuclear Information System (INIS)

    Kam, F.B.K.; Maerker, R.E.; Stallmann, F.W.

    1984-01-01

    The metallurgical irradiation experiment at the Oak Ridge Research Reactor Poolside Facility (ORR-PSF) was designed as a benchmark to test the accuracy of radiation embrittlement predictions in the pressure vessel wall of light water reactors on the basis of results from surveillance capsules. The PSF metallurgical Blind Test is concerned with the simulated surveillance capsule (SSC) and the simulated pressure vessel capsule (SPVC). The data from the ORR-PSF benchmark experiment are the basis for comparison with the predictions made by participants of the metallurgical ''Blind Test''. The Blind Test required the participants to predict the embrittlement of the irradiated specimen based only on dosimetry and metallurgical data from the SSC1 capsule. This exercise included both the prediction of damage fluence and the prediction of embrittlement based on the predicted fluence. A variety of prediction methodologies was used by the participants. No glaring biases or other deficiencies were found, but neither were any of the methods clearly superior to the others. Closer analysis shows a rather complex and poorly understood relation between fluence and material damage. Many prediction formulas can give an adequate approximation, but further improvement of the prediction methodology is unlikely at this time given the many unknown factors. Instead, attention should be focused on determining realistic uncertainties for the predicted material changes. The Blind Test comparisons provide some clues for the size of these uncertainties. In particular, higher uncertainties must be assigned to materials whose chemical composition lies outside the data set for which the prediction formula was obtained. 16 references, 14 figures, 5 tables

  19. Test results on systems developed for SST-1 tokamak

    International Nuclear Information System (INIS)

    Bora, D.

    2003-01-01

    Steady state Superconducting Tokamak (SST-1) is a large aspect ratio tokamak, configured to run double null diverted plasmas with significant elongation (κ) and triangularity Superconducting (SC) magnets are deployed for both the toroidal and poloidal field coils in SST-1. A NbTi based cable-in-conduit conductor (CICC) has been fabricated by M/S Hitachi Cables Ltd., Japan under specification and supervision of IPR. The suitability of this CICC for the SST-1 magnets has been validated through test carried out on a model coil (MC) wound from this CICC. Toroidal and poloidal SC magnets have been fabricated and factory acceptance tests have been performed. SC magnets require liquid helium (LHe) cooled current leads, electrical isolators at LHe temperature, superconducting bus bars and LHe transfer lines. Full scale prototypes of these have been developed and tested successfully. SC magnets will be cooled to 4.5K by forced flow of supercritical Helium through the CICC. A 1 kW grade liquefier/refrigerator has been installed and is in final stages of commissioning at IPR. SST-1 deploys a fully welded ultra high vacuum vessel, made up of 16 vessel sectors having ports and 16 rings with D-shaped cross-section. To establish the fabrication methodology for this, a full scale proto-type of the vessel with two vessel sectors and three rings has been fabricated and tested successfully. Based on this the fabrication of the vessel sectors and rings is in final stage of fabrication. Liquid nitrogen cooled radiation shield are deployed between the vacuum vessel and SC magnets as well as SC magnets and cryostat, to minimize the radiation losses at the SC magnets. SST-1 will have three different high power radio frequency (RF) systems to additionally heat and non-inductively drive plasma current to sustain the plasma in steady state for a duration of up to 1000 sec. Ion cyclotron resonance frequency (ICRF) and electron cyclotron resonance frequency (ECRF) systems will primarily be

  20. Radiation budget measurement/model interface

    Science.gov (United States)

    Vonderhaar, T. H.; Ciesielski, P.; Randel, D.; Stevens, D.

    1983-01-01

    This final report includes research results from the period February, 1981 through November, 1982. Two new results combine to form the final portion of this work. They are the work by Hanna (1982) and Stevens to successfully test and demonstrate a low-order spectral climate model and the work by Ciesielski et al. (1983) to combine and test the new radiation budget results from NIMBUS-7 with earlier satellite measurements. Together, the two related activities set the stage for future research on radiation budget measurement/model interfacing. Such combination of results will lead to new applications of satellite data to climate problems. The objectives of this research under the present contract are therefore satisfied. Additional research reported herein includes the compilation and documentation of the radiation budget data set a Colorado State University and the definition of climate-related experiments suggested after lengthy analysis of the satellite radiation budget experiments.

  1. Multiple group radiator and hybrid test heads, possibilities of combining the array technique

    International Nuclear Information System (INIS)

    Wuestenberg, H.

    1993-01-01

    This article is intended to show the important considerations, which led to the development of the multichannel group radiator technique. Trends in development and the advantages and disadvantages of the different possibilities are introduced, against the background of experience now available for these configurative variants of ultrasonic test heads. For this reason, a series of experiences and arguments is reported, from the point of view of the developer of the multi-channel group radiator technique. (orig./HP) [de

  2. The design, build and test of a digital analyzer for mixed radiation fields

    International Nuclear Information System (INIS)

    Joyce, M. J.; Aspinall, M. D.; Georgopoulos, K.; Cave, F. D.; Jarrah, Z.

    2009-01-01

    The design, build and test of a digital analyzer for mixed radiation fields is described. This instrument has been developed to provide portable, real-time discrimination of hard mixed fields comprising both neutrons and γ rays with energies typically above 0.5 MeV. The instrument in its standard form comprises a sensor head and a system unit, and affords the flexibility to provide processed data in the form of the traditional scatter-plot representation separating neutron and γ-ray components, or the full, sampled pulse data itself. The instrument has been tested with an americium-beryllium source in three different shielding arrangements to replicate the case in which there are only neutrons, only γ rays and where both neutrons and γ-rays are present. The instrument is observed to return consistent results. (authors)

  3. Results of the gamma-neutron mapper performance test on 55-gallon drums at the RWMC

    International Nuclear Information System (INIS)

    Gehrke, R.J.; Lawrence, R.S.; Roybal, L.G.; Svoboda, J.M.; Harker, D.J.; Thompson, D.N.; Carpenter, M.V.; Josten, N.E.

    1995-07-01

    The primary purpose of the gamma-neutron mapper (G at sign) is to provide accurate and quantitative spatial information of the gamma-ray and neutron radiation fields as a function of position about the excavation of a radioactive waste site. The GNM is designed to operate remotely and can be delivered to any point on an excavation by the robotic gantry crane developed by the dig-face project at the Idaho National Engineering Laboratory (INEL). It can also be easily adapted to other delivery systems. The GNM can be deployed over a waste site at a predetermined scan rate and has sufficient accuracy to identify and quantify radioactive contaminants of importance. The results reported herein are from a performance test conducted at the Transuranic Storage Area, Building 628, of the Radioactive Waste Management Complex located at the INEL. This building is an active interim-storage area for 55-gal drums of transuranic waste from the Department of Energy's Rocky Flats Plant. The performance test consisted of scanning a stack of drums five high by five wide. Prior to the test, radiation fields were measured by a health physicist at the center of the drums and ranged from 0.5 mR/h to 35 mR/h. Scans of the drums using the GNM were taken at standoff distances from the vertical drum stack of 15 cm, 30 cm, 45 cm, and 90 cm. Data were acquired at scan speeds of 7.5 cm/s and 15 cm/s. The results of these scans and a comparison of these results with the manifests of these drums are compared and discussed

  4. The HAW-Project. Test disposal of highly radioactive radiation sources in the Asse salt mine. Final report

    International Nuclear Information System (INIS)

    Rothfuchs, T.; Cuevas, C. de las; Donker, H.; Feddersen, H.K.; Garcia-Celma, A.; Gies, H.; Goreychi, M.; Graefe, V.; Heijdra, J.; Hente, B.; Jockwer, N.; LeMeur, R.; Moenig, J.; Mueller, K.; Prij, J.; Regulla, D.; Smailos, E.; Staupendahl, G.; Till, E.; Zankl, M.

    1995-01-01

    In order to improve the final concept for the disposal of high-level radioactive waste (HAW) in boreholes drilled into salt formation plans were developed a couple of years ago for a full scale testing of the complete technical system of an underground repository. To satisfy the test objectives, thirty highly radioactive radiation sources were planned to be emplaced in six boreholes located in two test galleries at the 800-m-level in the Asse salt mine. A duration of testing of approximately five years was envisaged. Because of licensing uncertainties the German Federal Government decided on December 3rd, 1992 to stop all activities for the preparation of the test disposal immediately. In the course of the preparation of the test disposal, however, a system, necessary for handling of the radiation sources was developed and installed in the Asse salt mine and two non-radioactive reference tests with electrical heaters were started in November 1988. These tests served for the investigation of thermal effects in comparison to the planned radioactive tests. An accompanying scientific investigation programme performed in situ and in the laboratory comprises the estimation and observation of the thermal, radiation-induced, and mechanical interaction between the rock salt and the electrical heaters and the radiation sources, respectively. The laboratory investigations are carried out at Braunschweig (FRG), Petten (NL), Saclay (F) and Barcelona (E). As a consequence of the premature termination of the project the working programme was revised. The new programme agreed to by the project partners included a controlled shutdown of the heater tests in 1993 and a continuation of the laboratory activities until the end of 1994. (orig.)

  5. Experimental test of the shadowing effect in Smith-Purcell radiation

    International Nuclear Information System (INIS)

    Naumenko, G.A.; Potylitsyn, A.P.; Popov, Yu.A.; Shevelev, M.V

    2011-01-01

    The observation of a shadowing effect of a relativistic electron Coulomb field for the Smith-Purcell radiation generation is presented in this paper. For this purpose the surface current from the closest surface of grating element to the electron beam was measured for a downstream one shadowed by upstream element. The experimental results showed that shadowing effect for Smith-Purcell radiation depends on grating geometry.

  6. First Results from the Online Radiation Dose Monitoring System in ATLAS experiment

    CERN Document Server

    Mandić, I; The ATLAS collaboration; Deliyergiyev, M; Gorišek, A; Kramberger, G; Mikuž, M; Franz, S; Hartert, J; Dawson, I; Miyagawa, P; Nicolas, L

    2011-01-01

    High radiation doses which will accumulate in components of ATLAS experiment during data taking will causes damage to detectors and readout electronics. It is therefore important to continuously monitor the doses to estimate the level of degradation caused by radiation. Online radiation monitoring system measures ionizing dose in SiO2 , displacement damage in silicon in terms of 1-MeV(Si) equivalent neutron fluence and fluence of thermal neutrons at several locations in ATLAS detector. In this paper design of the system, results of measurements and comparison of measured integrated doses and fluences with predictions from FLUKA simulation will be shown.

  7. MITG test procedure and results

    International Nuclear Information System (INIS)

    Eck, M.E.; Mukunda, M.

    1983-01-01

    Elements and modules for Radioisotope Thermoelectric Generator have been performance tested since the inception of the RTG program. These test articles seldom resembled flight hardware and often lacked adequate diagnostic instrumentation. Because of this, performance problems were not identified in the early stage of program development. The lack of test data in an unexpected area often hampered the development of a problem solution. A procedure for conducting the MITG Test was developed in an effort to obtain data in a systematic, unambiguous manner. This procedure required the development of extensive data acquisition software and test automation. The development of a facility to implement the test procedure, the facility hardware and software requirements, and the results of the MITG testing are the subject of this paper

  8. Results of primary radiation therapy in early vocal cord cancers

    International Nuclear Information System (INIS)

    Mehta, S.A.; Sarkar, S.; Mehta, M.S.; Marfatia, P.T.; Choudhary, A.J.; Mehta, A.R.

    1991-01-01

    Results of 74 patients treated by primary radiation therapy with curative intent at the Tata Memorial Hospital between January 1980 and December 1984 are reported. Thirty three (44.6%) were classified as TlaNO, twenty five (33.8%) as TlbNO, ten (13.5%) as T2NO and six(8.1%) as TisNO. The 5-year actuarial survival was 92% and disease-free survival was 85%. Thirteen patients (17.5%) failed locally, seven (53.8%) of whom were salvaged by surgery. Radiation side-effects were minimal and there were no long term complications. Anterior commissure involvement did not affect the local recurrence rates. (author). 19 refs., 1 tabs

  9. Failure modes induced by natural radiation environments on DRAM memories: study, test methodology and mitigation technique

    International Nuclear Information System (INIS)

    Bougerol, A.

    2011-05-01

    DRAMs are frequently used in space and aeronautic systems. Their sensitivity to cosmic radiations have to be known in order to satisfy reliability requirements for critical applications. These evaluations are traditionally done with particle accelerators. However, devices become more complex with technology integration. Therefore new effects appear, inducing longer and more expensive tests. There is a complementary solution: the pulsed laser, which triggers similar effects as particles. Thanks to these two test tools, main DRAM radiation failure modes were studied: SEUs (Single Event Upset) in memory blocks, and SEFIs (Single Event Functional Interrupt) in peripheral circuits. This work demonstrates the influence of test patterns on SEU and SEFI sensitivities depending on technology used. In addition, this study identifies the origin of the most frequent type of SEFIs. Moreover, laser techniques were developed to quantify sensitive surfaces of the different effects. This work led to a new test methodology for industry, in order to optimize test cost and efficiency using both pulsed laser beams and particle accelerators. Finally, a new fault tolerant technique is proposed: based on DRAM cell radiation immunity when discharged, this technique allows to correct all bits of a logic word. (author)

  10. Irradiation Effects Test Series: Test IE-3. Test results report

    International Nuclear Information System (INIS)

    Farrar, L.C.; Allison, C.M.; Croucher, D.W.; Ploger, S.A.

    1977-10-01

    The objectives of the test reported were to: (a) determine the behavior of irradiated fuel rods subjected to a rapid power increase during which the possibility of a pellet-cladding mechanical interaction failure is enhanced and (b) determine the behavior of these fuel rods during film boiling following this rapid power increase. Test IE-3 used four 0.97-m long pressurized water reactor type fuel rods fabricated from previously irradiated fuel. The fuel rods were subjected to a preconditioning period, followed by a power ramp to 69 kW/m at a coolant mass flux of 4920 kg/s-m 2 . After a flow reduction to 2120 kg/s-m 2 , film boiling occurred on the fuel rods. One rod failed approximately 45 seconds after the reactor was shut down as a result of cladding embrittlement due to extensive cladding oxidation. Data are presented on the behavior of these irradiated fuel rods during steady-state operation, the power ramp, and film boiling operation. The effects of a power ramp and power ramp rates on pellet-cladding interaction are discussed. Test data are compared with FRAP-T3 computer model calculations and data from a previous Irradiation Effects test in which four irradiated fuel rods of a similar design were tested. Test IE-3 results indicate that the irradiated state of the fuel rods did not significantly affect fuel rod behavior during normal, abnormal (power ramp of 20 kW/m per minute), and accident (film boiling) conditions

  11. Radiation-resistance test on optical fiber for artificial satellite

    International Nuclear Information System (INIS)

    Morita, Yosuke; Seguchi, Tadao; Mori, Tatsuo; Miyaji, Yuji.

    1985-01-01

    Radiation resistance of a prototype optical fiber for use in artificial satellites is investigated under a long-term irradiation of gamma rays at relatively low dose rates. The optical fiber tested is composed of a pure silica core and an F-doped cladding. Various aspects of the relations between induced loss and irradiation time are observed and results obtained are discussed. It is generally accepted that a satellite and its equipment should be resistant to a total dose of about 1 x 10 6 rad. In the present test, accordingly, gamma ray irradiation is performed up to a total dose of 1 x 10 6 rad at a dose rate of 1 x 10 4 rad/h (for 100 h), 3 x 10 3 rad/h (333 h) and 1 x 10 3 rad/h (1000 h), and it is shown that the loss induced in this fiber at these dose rates is 23.6 - 27.2, 16.9 - 21.6 and 12.5 - 13.5 dB/km, respectively. On the other hand, it has been reported that the loss induced at the dose rate of 1 x 10 6 rad/h (1 h) is about 600 dB/km, which is much larger than the above values. From these results, the loss at a dose rate of 100 rad/h, which would be expected in a satellite, is estimated at about 10 dB/km. It is concluded that this prototype fiber has a sufficient capability for satellite use with respect to induced loss. (Nogami, K.)

  12. Evaluation of a draft standard on performance specifications for health physics instrumentation. Initial results for radiological tests

    International Nuclear Information System (INIS)

    Swinth, K.L.; Kenoyer, J.L.; Mileham, A.P.; Kathren, R.L.; Selby, J.M.

    1983-06-01

    The draft ANSI standard N42.17D2 on performance specifications for health physics instrumentation is currently being evaluated by the Pacific Northwest Laboratory. The primary objective of the project is the evaluation of the applicability and practicality of the proposed standard through testing of a cross-section of currently available commercial instruments to determine how well they conform to the standard. The standard is being tested against instruments such as ionization chambers, G.M. detectors, alpha survey meters, and neutron dose equivalent survey meters. This paper presents results of the preliminary radiological performance tests on ionization chambers and G.M. detectors. This includes both the data generated during the tests and a discussion of procedures developed to perform the testing. Results are reported for response time, accuracy, precision, radiation overloads, and angular dependence. In addition, results are reported for parameters that affect instrument performance including battery lifetime, geotropism and stability. Initial test indicates that some of the instruments will not meet the criteria specified in ANSI N42.17D2. Results cover approximately 40 instruments that have been obtained by direct purchase, by loan from instrument vendors or by loan from others including DOE licensees

  13. On Dimensions of OTA Setups for Massive MIMO Base Stations Radiated Testing

    DEFF Research Database (Denmark)

    Kyösti, Pekka; Fan, Wei; Pedersen, Gert F.

    2016-01-01

    The development of base stations (BS) with large aperture antenna arrays, enabled partially by the utilization of cmWave and mmWave frequency bands, will require radiated testing in fading conditions. In this paper, the objective is to investigate the suitable measurement distances and physical...

  14. Offsite environmental monitoring report. Radiation monitoring around United States nuclear test areas, calendar year 1981

    International Nuclear Information System (INIS)

    Black, S.C.; Grossman, R.F.; Mullen, A.A.; Potter, G.D.; Smith, D.D.; Hopper, J.L.

    1982-08-01

    This report, prepared in accordance with the guidelines in DOE/E-0023 (DOE 1981), covers the program activities conducted around Nevada Test Site (NTS) for calendar year 1981. It contains descriptions of pertinent features of the NTS and its environs, summaries of the dosimetry and sampling methods, analytical procedures, and the analytical results from environmental measurements. Where applicable, dosimetry and sampling data are compared to appropriate guides for external and internal exposures of humans to ionizing radiation. The monitoring networks detected no radioactivity in the various media which could be attributed to US nuclear testing. Small amounts of fission products were detected in air samples as a result of the People's Republic of China nuclear test and atmospheric krypton-85 increased, following the trend beginning in 1960, due to increased use of nuclear technology. Strontium-90 in milk and cesium-137 in meat samples continued the slow decline as observed for the last several years

  15. Offsite environmental monitoring report. Radiation monitoring around United States nuclear test areas, calendar year 1981

    Energy Technology Data Exchange (ETDEWEB)

    Black, S.C.; Grossman, R.F.; Mullen, A.A.; Potter, G.D.; Smith, D.D.; Hopper, J.L. (comps.)

    1982-08-01

    This report, prepared in accordance with the guidelines in DOE/E-0023 (DOE 1981), covers the program activities conducted around Nevada Test Site (NTS) for calendar year 1981. It contains descriptions of pertinent features of the NTS and its environs, summaries of the dosimetry and sampling methods, analytical procedures, and the analytical results from environmental measurements. Where applicable, dosimetry and sampling data are compared to appropriate guides for external and internal exposures of humans to ionizing radiation. The monitoring networks detected no radioactivity in the various media which could be attributed to US nuclear testing. Small amounts of fission products were detected in air samples as a result of the People's Republic of China nuclear test and atmospheric krypton-85 increased, following the trend beginning in 1960, due to increased use of nuclear technology. Strontium-90 in milk and cesium-137 in meat samples continued the slow decline as observed for the last several years.

  16. Ablative stabilization of Rayleigh-Taylor instabilities resulting from a laser-driven radiative shock

    Science.gov (United States)

    Huntington, C. M.; Shimony, A.; Trantham, M.; Kuranz, C. C.; Shvarts, D.; Di Stefano, C. A.; Doss, F. W.; Drake, R. P.; Flippo, K. A.; Kalantar, D. H.; Klein, S. R.; Kline, J. L.; MacLaren, S. A.; Malamud, G.; Miles, A. R.; Prisbrey, S. T.; Raman, K. S.; Remington, B. A.; Robey, H. F.; Wan, W. C.; Park, H.-S.

    2018-05-01

    The Rayleigh-Taylor (RT) instability is a common occurrence in nature, notably in astrophysical systems like supernovae, where it serves to mix the dense layers of the interior of an exploding star with the low-density stellar wind surrounding it, and in inertial confinement fusion experiments, where it mixes cooler materials with the central hot spot in an imploding capsule and stifles the desired nuclear reactions. In both of these examples, the radiative flux generated by strong shocks in the system may play a role in partially stabilizing RT instabilities. Here, we present experiments performed on the National Ignition Facility, designed to isolate and study the role of radiation and heat conduction from a shock front in the stabilization of hydrodynamic instabilities. By varying the laser power delivered to a shock-tube target with an embedded, unstable interface, the radiative fluxes generated at the shock front could be controlled. We observe decreased RT growth when the shock significantly heats the medium around it, in contrast to a system where the shock did not produce significant heating. Both systems are modeled with a modified set of buoyancy-drag equations accounting for ablative stabilization, and the experimental results are consistent with ablative stabilization when the shock is radiative. This result has important implications for our understanding of astrophysical radiative shocks and supernova radiative hydrodynamics [Kuranz et al., Nature Communications 9(1), 1564 (2018)].

  17. Report on results of seventeen years in consultations of radiation exposed pregnant women

    International Nuclear Information System (INIS)

    Bruening, L.; Arndt, D.; Laude, G.

    1992-01-01

    In a survey it will be given results of consultations of pregnant women exposed during the pregnancy in the period of 1976 to 1992 formerly in the National Board of Atomic Safety and Radiation Protection of the GDR and since 1990 in the Clinic-diagnostical Division of the Federal Health Office. The report includes dose estimations of the embryo and medical assessments of 430 pregnant women. The radiation exposure were mainly received by X-ray diagnostic (n = 406 cases) and the others by applications of radiation in nuclear medicine, research and vocational training (n = 24 cases). Results of dose and risk estimation were summarized in tables. Women having incurred fetal doses in excess of 100 mGy were recommended to interrupt pregnancy. A fetal dose above 100 mGy occured in 9 cases. The anatomico-pathological and embryological findings of the embryo or fetus showed only in one case a reference of teratogenic radiation damage. (orig.) [de

  18. Results of the 2004 Association of Residents in Radiation Oncology (ARRO) Survey

    International Nuclear Information System (INIS)

    Patel, Shilpen; Jagsi, Reshma; Wilson, John; Frank, Steven; Thakkar, Vipul V.; Hansen, Eric K.

    2006-01-01

    Purpose: The aim of this study was to document adequacy of training, career plans after residency, use of the in-service examination, and motivation for choice of radiation oncology as a specialty. Methods and Materials: In 2004, the Association of Residents in Radiation Oncology (ARRO) conducted a nationwide survey of all radiation oncology residents in the United States. Results: The survey was returned by 297 residents (response rate, 54%). Of the respondents, 29% were female and 71% male. The most popular career choice was joining an established private practice (38%), followed by a permanent academic career (29%). Residents for whom a permanent academic career was not their first choice were asked whether improvements in certain areas would have led them to be more likely to pursue an academic career. The most commonly chosen factors that would have had a strong or moderate influence included higher salary (81%), choice of geographic location (76%), faculty encouragement (68%), and less time commitment (68%). Of respondents in the first 3 years of training, 78% believed that they had received adequate training to proceed to the next level of training. Of those in their fourth year of training, 75% believed that they had received adequate training to enter practice. Conclusions: Multiple factors affect the educational environment of physicians in training. Data describing concerns unique to resident physicians in radiation oncology are limited. The current survey was designed to explore a variety of issues confronting radiation oncology residents. Training programs and the Residency Review Committee should consider these results when developing new policies to improve the educational experiences of residents in radiation oncology

  19. Possibility of use of plant test systems for estimation of degree risk at radiation influence

    International Nuclear Information System (INIS)

    Gogebashvili, M.E; Ivanishvili, N.I.

    2011-01-01

    (in some cases, frequency of occurrence) negative event (irradiation), a damage (number of deviations from norm or deadly outcomes) at event realization. The biological model offered by us in essence is a version of expert judgments of an estimation of risk, at radiating influence. Thus from positions of practical application of this test system to become important and that, how much this influence is modified by various concomitant factors.In whole, as a result of the spent researches it is shown, that the given model can serve as convenient test system at studying of the remote effects of radiation and definition of degree of risk at their formation.

  20. Test of atomic theory by photoelectron spectrometry with synchrotron radiation

    International Nuclear Information System (INIS)

    Krause, M.O.

    1984-01-01

    The successful combination of synchrotron radiation with electron spectrometry, accomplished at Daresbury, England and Orsay, France, made it possible to investigate sigma/sub x/ and β/sub x/ continuously over the very soft x-ray or the uv range of photon energies. The detailed and highly differentiated data resulting from this advanced experimentation put theory to a stringent test. In the interplay between theory and experiment, sophisticated Hartree Fock (HF) based models were developed which included both relativistic and many-electron effects. These theoretical models have provided us with a better insight than previously possible into the physics of the photon-atom interaction and the electronic structure and dynamics of atoms. However, critical experiments continue to be important for further improvements of theory. A number of such experiments are discussed in this presentation. The dynamic properties determined in these studies include in addition to sigma/sub x/ and β/sub x/ the spin polarization parameters. As a result the comparison between theory and experiment becomes rigorous, detailed and comprehensive. 46 references, 6 figures

  1. Alternative filtration testing program: Pre-evaluation of test results

    International Nuclear Information System (INIS)

    Georgeton, G.K.; Poirier, M.R.

    1990-01-01

    Based on results of testing eight solids removal technologies and one pretreatment option, it is recommended that a centrifugal ultrafilter and polymeric ultrafilter undergo further testing as possible alternatives to the Norton Ceramic filters. Deep bed filtration should be considered as a third alternative, if a backwashable cartridge filter is shown to be inefficient in separate testing

  2. Alternative filtration testing program: Pre-evaluation of test results

    Energy Technology Data Exchange (ETDEWEB)

    Georgeton, G.K.; Poirier, M.R.

    1990-09-28

    Based on results of testing eight solids removal technologies and one pretreatment option, it is recommended that a centrifugal ultrafilter and polymeric ultrafilter undergo further testing as possible alternatives to the Norton Ceramic filters. Deep bed filtration should be considered as a third alternative, if a backwashable cartridge filter is shown to be inefficient in separate testing.

  3. Construction of computational program of aging in insulating materials for searching reversed sequential test conditions to give damage equivalent to simultaneous exposure of heat and radiation

    International Nuclear Information System (INIS)

    Fuse, Norikazu; Homma, Hiroya; Okamoto, Tatsuki

    2013-01-01

    Two consecutive numerical calculations on degradation of polymeric insulations under thermal and radiation environment are carried out to simulate so-called reversal sequential acceleration test. The aim of the calculation is to search testing conditions which provide material damage equivalent to the case of simultaneous exposure of heat and radiation. At least following four parameters are needed to be considered in the sequential method; dose rate and exposure time in radiation, as well as temperature and aging time in heating. The present paper discusses the handling of these parameters and shows some trial calculation results. (author)

  4. Environmental radiation measurements at the former Soviet Union's Semipalatinsk nuclear test site and surrounding villages

    International Nuclear Information System (INIS)

    Shebell, P.; Hutter, A.R.

    1996-07-01

    Two scientists from the U.S. Department of Energy's Environmental Measurements Laboratory served as scientific experts to the International Atomic Energy Agency's (IAEA) Mission to Kazakhstan: Strengthening Radiation and Nuclear Safety Infrastructures in Countries of the former USSR, Special Task - Preassessment of the radiological situation in the Semipalatinsk and western areas of Kazakhstan. The former Soviet Union's largest nuclear test site was located near Semipalatinsk, Kazakhstan, and following Kazakhstan's independence, the IAEA committed to studying the environmental contamination and the resulting radiation exposure risk to the population due to 346 underground, 87 atmospheric and 26 surface nuclear detonations performed at the site between 1949 and 1989. As part of an 11-member team, environmental radiation measurements were performed during 2 weeks in July 1994. Approximately 30 sites were visited both within the boundaries of the Semipalatinsk nuclear test site as well as in and around surrounding villages. Specifically, the objectives of the EML team were to apply independent methods and equipment to assess potential current radiation exposures to the population. Towards this end, the EML scientists collected in-situ gamma-ray spectra, performed external gamma dose rate measurements using pressurized ionization chambers, and collected soil samples in order to estimate the inventory and to determine the depth distribution of radionuclides of interest. With the exception of an area near an open-quotes atomic lakeclose quotes and a 1 km 2 area encompassing ground zero, all the areas visited by the team had external dose rates that were within typical environmental levels. The measurements taken within a 15 km radius of ground zero had elevated levels of 137 Cs as well as the activation products 152 Eu and 60 Co, The dose rate within a 1 km radius of ground zero ranged from 500 to 30000 nGy h -1

  5. Test beam studies of possibilities to separate particles with gamma factors above 103 with straw based Transition Radiation Detector

    Science.gov (United States)

    Belyaev, N.; Cherry, M. L.; Doronin, S. A.; Filippov, K.; Fusco, P.; Konovalov, S.; Krasnopevtsev, D.; Kramarenko, V.; Loparco, F.; Mazziotta, M. N.; Ponomarenko, D.; Pyatiizbyantseva, D.; Radomskii, R.; Rembser, C.; Romaniouk, A.; Savchenko, A.; Shulga, E.; Smirnov, S.; Smirnov, Yu; Sosnovtsev, V.; Spinelli, P.; Teterin, P.; Tikhomirov, V.; Vorobev, K.; Zhukov, K.

    2017-12-01

    Measurements of hadron production in the TeV energy range are one of the tasks of the future studies at the Large Hadron Collider (LHC). The main goal of these experiments is a study of the fundamental QCD processes at this energy range, which is very important not only for probing of the Standard Model but also for ultrahigh-energy cosmic particle physics. One of the key elements of these experiments measurements are hadron identification. The only detector technology which has a potential ability to separate hadrons in this energy range is Transition Radiation Detector (TRD) technology. TRD prototype based on straw proportional chambers combined with a specially assembled radiator has been tested at the CERN SPS accelerator beam. The test beam results and comparison with detailed Monte Carlo simulations are presented here.

  6. A simple quality assurance test tool for the visual verification of light and radiation field congruent using electronic portal images device and computed radiography

    Directory of Open Access Journals (Sweden)

    Njeh Christopher F

    2012-03-01

    Full Text Available Abstract Background The radiation field on most megavoltage radiation therapy units are shown by a light field projected through the collimator by a light source mounted inside the collimator. The light field is traditionally used for patient alignment. Hence it is imperative that the light field is congruent with the radiation field. Method A simple quality assurance tool has been designed for rapid and simple test of the light field and radiation field using electronic portal images device (EPID or computed radiography (CR. We tested this QA tool using Varian PortalVision and Elekta iViewGT EPID systems and Kodak CR system. Results Both the single and double exposure techniques were evaluated, with double exposure technique providing a better visualization of the light-radiation field markers. The light and radiation congruency could be detected within 1 mm. This will satisfy the American Association of Physicists in Medicine task group report number 142 recommendation of 2 mm tolerance. Conclusion The QA tool can be used with either an EPID or CR to provide a simple and rapid method to verify light and radiation field congruence.

  7. The 88-Inch Cyclotron: A One-Stop Facility for Electronics Radiation and Detector Testing

    Energy Technology Data Exchange (ETDEWEB)

    Kireeff Covo, M.; Albright, R. A.; Ninemire, B. F.; Johnson, M. B.; Hodgkinson, A.; Loew, T.; Benitez, J. Y.; Todd, D. S.; Xie, D. Z.; Perry, T.; Phair, L.; Bernsteiny, L. A.; Bevins, J.; Brown, J. A.; Goldblum, B. L.; Harasty, M.; Harrig, K. P.; Laplace, T. A.; Matthews, E. F.; Bushmaker, A.; Walker, D.; Oklejas, V.; Hopkins, A. R.; Bleuel, D. L.; Chen, J.; Cronin, S. B.

    2017-10-01

    In outer space down to the altitudes routinely flown by larger aircrafts, radiation can pose serious issues for microelectronics circuits. The 88-Inch Cyclotron at Lawrence Berkeley National Laboratory is a sector-focused cyclotron and home of the Berkeley Accelerator Space Effects Facility, where the effects of energetic particles on sensitive microelectronics are studied with the goal of designing electronic systems for the space community. This paper describes the flexibility of the facility and its capabilities for testing the bombardment of electronics by heavy ions, light ions, and neutrons. Experimental capabilities for the generation of neutron beams from deuteron breakups and radiation testing of carbon nanotube field effect transistor will be discussed.

  8. Radiation Attenuation and Stability of ClearView Radiation Shielding TM-A Transparent Liquid High Radiation Shield.

    Science.gov (United States)

    Bakshi, Jayeesh

    2018-04-01

    Radiation exposure is a limiting factor to work in sensitive environments seen in nuclear power and test reactors, medical isotope production facilities, spent fuel handling, etc. The established choice for high radiation shielding is lead (Pb), which is toxic, heavy, and abidance by RoHS. Concrete, leaded (Pb) bricks are used as construction materials in nuclear facilities, vaults, and hot cells for radioisotope production. Existing transparent shielding such as leaded glass provides minimal shielding attenuation in radiotherapy procedures, which in some cases is not sufficient. To make working in radioactive environments more practicable while resolving the lead (Pb) issue, a transparent, lightweight, liquid, and lead-free high radiation shield-ClearView Radiation Shielding-(Radium Incorporated, 463 Dinwiddie Ave, Waynesboro, VA). was developed. This paper presents the motivation for developing ClearView, characterization of certain aspects of its use and performance, and its specific attenuation testing. Gamma attenuation testing was done using a 1.11 × 10 Bq Co source and ANSI/HPS-N 13.11 standard. Transparency with increasing thickness, time stability of liquid state, measurements of physical properties, and performance in freezing temperatures are reported. This paper also presents a comparison of ClearView with existing radiation shields. Excerpts from LaSalle nuclear power plant are included, giving additional validation. Results demonstrated and strengthened the expected performance of ClearView as a radiation shield. Due to the proprietary nature of the work, some information is withheld.

  9. Retrospective results of radiation therapy of the Eustachian tube in chronic otitis media

    International Nuclear Information System (INIS)

    Schultze, J.; Reinke, C.; Kimmig, B.; Frese, K.A.

    2003-01-01

    Background: The treatment results of symptomatic radiation therapy of the Eustachian tube in chronic otitis media had to be evaluated retrospectively. Patients and Methods: Between 1980 and 1997, 66 patients were referred for therapy. The median age was 58 years. In the clinical presentation, all the patients had a hearing impairment, 35 patients complained of pain, 21 had otorrhea. In their history, 20 patients indicated chronic recurrent infections. The complaints lasted for 4.7 years in the median, primary conservative (adstringentia, antibiotics) and surgical treatment (paracentesis, tympanic tubule, tympanoplastic) did not lead to lasting cure. In 40 of 66 patients, finally radiation therapy was done of both Eustachian tubes. With opposed fields and cobalt-60 photons a total dose of 6 Gy at single doses of 1 Gy, three times a week, was applied. Under the causes for exclusion of radiation therapy were non-acceptance of the patients (nine), prior radiation therapies (six) or spontaneous improvement after initial presentation in our department. The treatment results were evaluated by interviews of the patients and regular otorhinolaryngological examinations. Results: There were no side effects noticed. 28 of 40 (70%) patients reported a significant improvement that could be verified by objective otorhinolaryngological examinations. In the group of 26 nonirradiated patients, 22 could be interviewed indicating in 16 cases (72%) that the complaints were unchanged and chronic otitis media was lasting. In a subgroup analysis concerning the duration of otitis media radiation therapy proved more effective in an acute and subacute stadium of disease of up to 5 years duration, while the patients resistant to radiation therapy were entirely in a chronic stage of disease exceeding 5 years duration. (orig.) [de

  10. Design and Test of a Deployable Radiation Cover for the REgolith X-Ray Imaging Spectrometer

    Science.gov (United States)

    Carte, David B.; Inamdar, Niraj K.; Jones, Michael P.; Masterson, Rebecca A.

    2014-01-01

    The REgolith X-ray Imaging Spectrometer (REXIS) instrument contains a one-time deployable radiation cover that is opened using a shape memory alloy actuator (a "Frangibolt") from TiNi Aerospace and two torsion springs. The door will be held closed by the bolt for several years in cold storage during travel to the target asteroid, Bennu, and it is imperative to gain confidence that the door will open at predicted operational temperatures. This paper briefly covers the main design features of the radiation cover and measures taken to mitigate risks to cover deployment. As the chosen FD04 model Frangibolt actuator has minimal flight heritage, the main focus of this paper is the testing, results and conclusions with the FD04 while discussing key lessons learned with respect to the use of the FD04 actuator in this application.

  11. Irradiation effects test series test IE-1 test results report

    International Nuclear Information System (INIS)

    Quapp, W.J.; Allison, C.M.; Farrar, L.C.; Mehner, A.S.

    1977-03-01

    The report describes the results of the first programmatic test in the Nuclear Regulatory Commission Irradiation Effects Test Series. This test (IE-1) used four 0.97m long PWR-type fuel rods fabricated from previously irradiated Saxton fuel. The objectives of this test were to evaluate the effect of fuel pellet density on pellet-cladding interaction during a power ramp and to evaluate the influence of the irradiated state of the fuel and cladding on rod behavior during film boiling operation. Data are presented on the behavior of irradiated fuel rods during steady-state operation, a power ramp, and film boiling operation. The effects of as-fabricated gap size, as-fabricated fuel density, rod power, and power ramp rate on pellet-cladding interaction are discussed. Test data are compared with FRAP-T2 computer model predictions, and comments on the consequences of sustained film boiling operation on irradiated fuel rod behavior are provided

  12. Possibility of use of plat test systems for estimation of degree risk at radiation influence

    International Nuclear Information System (INIS)

    Gogebashvili, M.E.; Ivanishvili, N.I.

    2010-01-01

    . The biological model in essence is a version of expert judgments of an estimation of risk, at radiating influence. Thus from positions of practical application of this test system to become important and that, how much this influence is modified by various concomitant factors. In whole, as a result of the spent researches it is shown, that the given model can serve as convenient test system at studying of the remote effects of radiation and definition of degree of risk at their formation.

  13. Irradiation effects test series, test IE-5. Test results report. [PWR

    Energy Technology Data Exchange (ETDEWEB)

    Croucher, D. W.; Yackle, T. R.; Allison, C. M.; Ploger, S. A.

    1978-01-01

    Test IE-5, conducted in the Power Burst Facility at the Idaho National Engineering Laboratory, employed three 0.97-m long pressurized water reactor type fuel rods, fabricated from previously irradiated zircaloy-4 cladding and one similar rod fabricated from unirradiated cladding. The objectives of the test were to evaluate the influence of simulated fission products, cladding irradiation damage, and fuel rod internal pressure on pellet-cladding interaction during a power ramp and on fuel rod behavior during film boiling operation. The four rods were subjected to a preconditioning period, a power ramp to an average fuel rod peak power of 65 kW/m, and steady state operation for one hour at a coolant mass flux of 4880 kg/s-m/sup 2/ for each rod. After a flow reduction to 1800 kg/s-m/sup 2/, film boiling occurred on one rod. Additional flow reductions to 970 kg/s-m/sup 2/ produced film boiling on the three remaining fuel rods. Maximum time in film boiling was 80s. The rod having the highest initial internal pressure (8.3 MPa) failed 10s after the onset of film boiling. A second rod failed about 90s after reactor shutdown. The report contains a description of the experiment, the test conduct, test results, and results from the preliminary postirradiation examination. Calculations using a transient fuel rod behavior code are compared with the test results.

  14. Radiation-resistant control system

    International Nuclear Information System (INIS)

    Cable, T.C.; Jones, S.

    1995-01-01

    REMOTEC has developed a open-quotes radiation resistanceclose quotes control system under a U.S. Department of Energy Small Business Innovative Research (SBIR) contract with assistance from the University of Florida. The SBIR goal was to develop a radiation resistant mobile robot from the ANDROS family of hazardous duty mobile robots that REMOTEC manufactures. See Refs. 1 and 2 for additional SBIR results. The control system, as well as the entire ANDROS robot, was redesigned, where necessary, to withstand radiation doses in excess of 10 6 rad. Those components of the robot that could not be purchased as open-quotes radiation hardenedclose quotes were tested under standard operating conditions for determination of their open-quotes radiation resistance.close quotes The entire ANDROS robot was then assembled with these new components and tested to > 10 6 rad

  15. Characteristics of X ray calibration fields for performance test of radiation measuring instruments

    International Nuclear Information System (INIS)

    Shimizu, Shigeru; Takahashi, Fumiaki; Sawahata, Tadahiro; Tohnami, Kohichi; Kikuchi, Hiroshi; Murayama, Takashi

    1999-02-01

    Performance test and calibration of the radiation measuring instruments for low energy photons are made using the X ray calibration fields which are monochromatically characterized by filtration of continuous X ray spectrum. The X ray calibration field needs to be characterized by some quality conditions such as quality index and homogeneity coefficient. The present report describes quality conditions, spectrum and some characteristics of X ray irradiation fields in the Facility of Radiation Standard of the Japan Atomic Energy Research Institute (FRS-JAERI). Fifty nine X ray qualities with the quality index of 0.6, 0.7, 0.8 and 0.9 were set for the tube voltages between 10 kV and 350 kV. Estimation of X ray spectrum measured with a Ge detector was made in terms of exposure, ambient dose equivalent and fluence for all the obtained qualities. Practical irradiation field was determined as the dose distribution uniformity is within ±3%. The obtained results improve the quality of X ray calibration fields and calibration accuracy. (author)

  16. Ionizing radiation and the conceptus: neurophysiologic effects of prenatal X-radiation on offspring

    International Nuclear Information System (INIS)

    Jensh, R.P.

    1985-01-01

    A brief review of the literature precedes the presentation of a radiation behavioral teratology study. The various types of radiation and the units of measure used in radiation biology are discussed. The concept of the radiation-induced teratogenic ''triad'' of growth retardation, malformation, and death is presented. A discussion of stage- and dose-dependent sensitivity to prenatal irradiation is followed by an introduction to behavioral teratology as a new interdisciplinary area of investigation, emphasizing postnatal psychophysiologic analyses of the effects of prenatal exposure. In the present study, rats were exposed to an acute dosage level of 0.6 Gy (60 RAD) X-radiation on day 9 or 17 of gestation. The neonates were given five neonatal reflex tests, observed for the appearance of four physiologic markers, and, as young adults, subjected to three of six behavioral tests. The irradiated offspring exhibited retarded postnatal growth and altered reflex and behavioral activity. These results indicate that irradiation at a dosage level which does not cause overt morphologic malformations at birth does result in altered postnatal growth and psychophysiologic development

  17. Radiation-induced signaling results in mitochondrial impairment in mouse heart at 4 weeks after exposure to X-rays.

    Science.gov (United States)

    Barjaktarovic, Zarko; Schmaltz, Dominik; Shyla, Alena; Azimzadeh, Omid; Schulz, Sabine; Haagen, Julia; Dörr, Wolfgang; Sarioglu, Hakan; Schäfer, Alexander; Atkinson, Michael J; Zischka, Hans; Tapio, Soile

    2011-01-01

    Radiation therapy treatment of breast cancer, Hodgkin's disease or childhood cancers expose the heart to high local radiation doses, causing an increased risk of cardiovascular disease in the survivors decades after the treatment. The mechanisms that underlie the radiation damage remain poorly understood so far. Previous data show that impairment of mitochondrial oxidative metabolism is directly linked to the development of cardiovascular disease. In this study, the radiation-induced in vivo effects on cardiac mitochondrial proteome and function were investigated. C57BL/6N mice were exposed to local irradiation of the heart with doses of 0.2 Gy or 2 Gy (X-ray, 200 kV) at the age of eight weeks, the control mice were sham-irradiated. After four weeks the cardiac mitochondria were isolated and tested for proteomic and functional alterations. Two complementary proteomics approaches using both peptide and protein quantification strategies showed radiation-induced deregulation of 25 proteins in total. Three main biological categories were affected: the oxidative phophorylation, the pyruvate metabolism, and the cytoskeletal structure. The mitochondria exposed to high-dose irradiation showed functional impairment reflected as partial deactivation of Complex I (32%) and Complex III (11%), decreased succinate-driven respiratory capacity (13%), increased level of reactive oxygen species and enhanced oxidation of mitochondrial proteins. The changes in the pyruvate metabolism and structural proteins were seen with both low and high radiation doses. This is the first study showing the biological alterations in the murine heart mitochondria several weeks after the exposure to low- and high-dose of ionizing radiation. Our results show that doses, equivalent to a single dose in radiotherapy, cause long-lasting changes in mitochondrial oxidative metabolism and mitochondria-associated cytoskeleton. This prompts us to propose that these first pathological changes lead to an increased

  18. Combined Global MHD and Test-Particle Simulation of a Radiation Belt Storm: Comparing Depletion, Recovery and Enhancement with in Situ Measurements

    Science.gov (United States)

    Sorathia, K.; Ukhorskiy, A. Y.; Merkin, V. G.; Wiltberger, M. J.; Lyon, J.; Claudepierre, S. G.; Fennell, J. F.

    2017-12-01

    During geomagnetic storms the intensities of radiation belt electrons exhibit dramatic variability. In the main phase electron intensities exhibit deep depletion over a broad region of the outer belt. The intensities then increase during the recovery phase, often to levels that significantly exceed their pre-storm values. In this study we analyze the depletion, recovery and enhancement of radiation belt intensities during the 2013 St. Patrick's geomagnetic storm. We simulate the dynamics of high-energy electrons using our newly-developed test-particle radiation belt model (CHIMP) based on a hybrid guiding-center/Lorentz integrator and electromagnetic fields derived from high-resolution global MHD (LFM) simulations. Our approach differs from previous work in that we use MHD flow information to identify and seed test-particles into regions of strong convection in the magnetotail. We address two science questions: 1) what are the relative roles of magnetopause losses, transport-driven atmospheric precipitation, and adiabatic cooling in the radiation belt depletion during the storm main phase? and 2) to what extent can enhanced convection/mesoscale injections account for the radiation belt buildup during the recovery phase? Our analysis is based on long-term model simulation and the comparison of our model results with electron intensity measurements from the MAGEIS experiment of the Van Allen Probes mission.

  19. Testing and analysis on total protein, albumin and A/G of salivary in radiation exposure persons

    International Nuclear Information System (INIS)

    Wang Jun; Zhang Yan; Li Guangwen; Li Gang; Guo Jing; Li Hui; Wang Yuxin; Li Cuixia

    2012-01-01

    Objective: To study the oral health effect of long term low dose radiation on exposure personnel and to provide a basis for further improving the protection ability. Methods: Testing method, which was based on APT and HSA interactions induced by synchronous fluorescence specific changes, and intensity and concentrations of HSA in the solution in the system of synchronous fluorescence showed a good linear relations. the establishment of a APT as a molecular probe was used to test concentration of salivary total protein (TP), albumin (ALB), globulin (GLO) and albumin by synchronous fluorescence spectrum analysis. The information was analyzed in Foxpro 6.0 and SPSS 16.0 software. Result: Protein (TP) Mean Value was 3.904 ±1.369 g/L, Minimum Value was 0.30 g/L and Maximum Value was 7.50 g/L. Albumin (ALB) Mean Value was 0.965±0.665 g/L, Minimum Value was 0.09 g/L and Maximum Value was 3.98 g/L. Globulin (GLO) Mean Value was 2.895±0.947 g/L, Minimum Value was 0.01 g/L and Maximum Value was 5.81 g/L. A/G Mean Value was 0.327. Conclusion: Long term and low dose of radiation would break the chronic physiological balance and concentration of salivary total protein (TP), albumin (ALB), globulin (GLO) and albumin and globulin ratio (A/G) changed obviously. It was necessary to do more special oral health care, further improve the individual protection consciousness, strengthen the radiation monitoring and protection measures, improve the regulation system, and reduce radiation damage on special personnel health significantly. (authors)

  20. Test results of HTTR control system

    International Nuclear Information System (INIS)

    Motegi, Toshihiro; Iigaki, Kazuhiko; Saito, Kenji; Sawahata, Hiroaki; Hirato, Yoji; Kondo, Makoto; Shibutani, Hideki; Ogawa, Satoru; Shinozaki, Masayuki; Mizushima, Toshihiko; Kawasaki, Kozo

    2006-06-01

    The plant control performance of the IHX helium flow rate control system, the PPWC helium flow rate control system, the secondary helium flow rate control system, the inlet temperature control system, the reactor power control system and the outlet temperature control system of the HTTR are obtained through function tests and power-up tests. As the test results, the control systems show stable control response under transient condition. Both of inlet temperature control system and reactor power control system shows stable operation from 30% to 100%, respectively. This report describes the outline of control systems and test results. (author)

  1. Radiation effects on testes. XI. Studies on glycogen and its metabolizing enzymes following radiation-induced atrophy

    International Nuclear Information System (INIS)

    Gupta, G.S.; Bawa, S.R.

    1977-01-01

    Effect of radiation on enzymes of carbohydrate metabolism has been studied. It is observed that hexokinase of testis is highly sensitive to radiation damage. Reduced hexokinase activity seems to be related to those parts of the testis (spermatocytes and spermatids) which depend upon glucose for their functioning. Radiation-induced atrophic testis is rich in glycogen content. The observations on the inhibition of gluocose-6-phosphatase and phosphorylase may explain the higher levels of the polysaccharide although a possibility of enhanced glycogenesis due to the activation of glycogen synthetase has also been suggested. The presence of glucose-6-phosphate isomerase and glycogen in atrophied testis in 11-month-treated rats indicate the higher glycolytic activity with hyperplastic testicular interstitium. The results suggest that the accumulated glycogen is acting as a reserve substrate in nongerminal cells

  2. First Results of Modeling Radiation Belt Electron Dynamics with the SAMI3 Plasmasphere Model

    Science.gov (United States)

    Komar, C. M.; Glocer, A.; Huba, J.; Fok, M. C. H.; Kang, S. B.; Buzulukova, N.

    2017-12-01

    The radiation belts were one of the first discoveries of the Space Age some sixty years ago and radiation belt models have been improving since the discovery of the radiation belts. The plasmasphere is one region that has been critically important to determining the dynamics of radiation belt populations. This region of space plays a critical role in describing the distribution of chorus and magnetospheric hiss waves throughout the inner magnetosphere. Both of these waves have been shown to interact with energetic electrons in the radiation belts and can result in the energization or loss of radiation belt electrons. However, radiation belt models have been historically limited in describing the distribution of cold plasmaspheric plasma and have relied on empirically determined plasmasphere models. Some plasmasphere models use an azimuthally symmetric distribution of the plasmasphere which can fail to capture important plasmaspheric dynamics such as the development of plasmaspheric drainage plumes. Previous work have coupled the kinetic bounce-averaged Comprehensive Inner Magnetosphere-Ionosphere (CIMI) model used to model ring current and radiation belt populations with the Block-adaptive Tree Solar wind Roe-type Upwind Scheme (BATSRUS) global magnetohydrodynamic model to self-consistently obtain the magnetospheric magnetic field and ionospheric potential. The present work will utilize this previous coupling and will additionally couple the SAMI3 plasmasphere model to better represent the dynamics on the plasmasphere and its role in determining the distribution of waves throughout the inner magnetosphere. First results on the relevance of chorus, hiss, and ultralow frequency waves on radiation belt electron dynamics will be discussed in context of the June 1st, 2013 storm-time dropout event.

  3. A study on the radiation and environmental safety -Development of radiation protection and measurement technology-

    Energy Technology Data Exchange (ETDEWEB)

    Jang, See Yung; Lee, Tae Yung; Lee, Hyung Sub; Kim, Jan Ryul; Kim, Chang Kyung; Kim, Bong Hwan; Yoon, Kyung Soo; Jung, Kyung Kee; Jung, Duk Yun; Lee, Bong Jae; Chul, Yoon Suk; Lee, Kee Chang; Yoon, Yu Chang; Jung, Rae Ik; Lee, Sang Yoon; Han, Yung Dae; Kim, Jong Soo, I; Kim, Jong Soo, II; Suh, Kyung Won [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of); Kim, Jong Kyung [Han Yang Univ., Seoul (Korea, Republic of)

    1995-07-01

    Reference X- and neutron radiation fields have been established and evaluated to support the national radiation protection programme under which performance evaluation test for domestic personal dosimetry will be implemented by the ministerial ordinance 1992-15, and to provide a basic technical support in radiation protection dosimetry. Personal dose evaluation algorithm has been developed with the KAERI reference radiation fields which comply well with those in the new ANSI N13.11(1993) to evaluate accurate personal dose equivalents. A personal internal dosimetry algorithm which can estimate the intakes of radionuclides from the results of whole body direct bioassay and the resulting internal doses has been also developed and evaluated to be equally excellent compared with those being used in foreign countries. A BOMAB phantom for precise WBC calibration has also designed, fabricated and test-evaluated. A principal method for estimating the cost for radiation protection which is important in performing a cost-benefit analysis for the radiation protection optimization study based on the ALARA principle has been preliminarily investigated and suggested. 49 figs, 67 tabs, 50 refs. (Author).

  4. Radiation shielding and safety design

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Ouk; Gil, C. S.; Cho, Y. S.; Kim, D. H.; Kim, H. I.; Kim, J. W.; Lee, C. W.; Kim, K. Y.; Kim, B. H. [KAERI, Daejeon (Korea, Republic of)

    2011-07-15

    A benchmarking for the test facility, evaluations of the prompt radiation fields, evaluation of the induced activities in the facility, and estimation of the radiological impact on the environment were performed in this study. and the radiation safety analysis report for nuclear licensing was written based on this study. In the benchmark calculation, the neutron spectra was measured in the 20 Mev test facility and the measurements were compared with the computational results to verify the calculation system. In the evaluation of the prompt radiation fields, the shielding design for 100 MeV target rooms, evaluations of the leakage doses from the accidents and skyshine analysis were performed. The evaluation of the induced activities were performed for the coolant, inside air, structural materials, soil and ground-water. At last, the radiation safety analysis report was written based on results from these studies

  5. The Plateau de Bure ASTEP Platform Test in natural radiation environment of electronic components and circuits

    International Nuclear Information System (INIS)

    Autran, J.L.; Munteanu, D.; Sauze, S.; Roche, Ph.; Gasiot, G.; Borel, J.

    2010-01-01

    Reducing the size of microelectronic devices and increasing the integration density of circuits lead (following the famous Moore's law) to an increased sensitivity of circuits to natural terrestrial radiation environment. - Such sensitivity to atmospheric particles (mainly neutrons) can cause non-destructive (soft-errors) or destructive (latch-up) failures in most electronic circuits, including volatile static memories (SRAM), object of the research work carried out since 2004 on the European Test Platform ASTER. - This paper presents in details the ASTEP platform, its location, the instruments (neutron monitor of the Plateau de Bure) and the experiences (memory tester) currently installed on the Plateau de Bure. In a second part, we also report a synthesis of the key results concerning the natural radiation sensitivity of SRAM fabricated in 130 nm and 65 nm bulk silicon technologies. (authors)

  6. Standard Test Method for Measuring Dose for Use in Linear Accelerator Pulsed Radiation Effects Tests

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers a calorimetric measurement of the total dose delivered in a single pulse of electrons from an electron linear accelerator or a flash X-ray machine (FXR, e-beam mode) used as an ionizing source in radiation-effects testing. The test method is designed for use with pulses of electrons in the energy range from 10 to 50 MeV and is only valid for cases in which both the calorimeter and the test specimen to be irradiated are“thin” compared to the range of these electrons in the materials of which they are constructed. 1.2 The procedure described can be used in those cases in which (1) the dose delivered in a single pulse is 5 Gy (matl) (500 rd (matl)) or greater, or (2) multiple pulses of a lower dose can be delivered in a short time compared to the thermal time constant of the calorimeter. Matl refers to the material of the calorimeter. The minimum dose per pulse that can be acceptably monitored depends on the variables of the particular test, including pulse rate, pulse uniformity...

  7. The results of complex radiation-hygienic survey of the reference settlements in Mogilev region

    International Nuclear Information System (INIS)

    Ageeva, T.N.; Chegerova, T.I.; Shchur, A.V.; Shapsheeva, T.P.; Lipnitskij, L.V.

    2011-01-01

    The results of complex radiation-hygienic survey of the reference settlements located on the radioactively contaminated territory have been presents in the article. The four-year dynamics of the internal exposure doses of the reference settlements' inhabitants and their relationship with the 137 Cs content in foods consumed by the population have been shown. It was ascertained that there are still some isolated individuals with high doses of internal radiation among the surveyed population, which have the significant influence on the average annual radiation dose for the inhabitants and dose of its critical group. The external exposure individual doses of the inhabitants and the results of measuring of the gamma radiation dose rate in place of the settlements have been analyzed. It have been expressed the opinion about need entering adjustment in the measuring techniques of external doses. (authors)

  8. An Assessment of the Current US Radiation Oncology Workforce: Methodology and Global Results of the American Society for Radiation Oncology 2012 Workforce Study

    Energy Technology Data Exchange (ETDEWEB)

    Vichare, Anushree; Washington, Raynard; Patton, Caroline; Arnone, Anna [ASTRO, Fairfax, Virginia (United States); Olsen, Christine [Massachusetts General Hospital, Boston, Massachusetts, (United States); Fung, Claire Y. [Commonwealth Newburyport Cancer Center, Newburyport, Massachusetts (United States); Hopkins, Shane [William R. Bliss Cancer Center, Ames, Iowa (United States); Pohar, Surjeet, E-mail: spohar@netzero.net [Indiana University Health Cancer Center East, Indiana University, Indianapolis, Indiana (United States)

    2013-12-01

    Purpose: To determine the characteristics, needs, and concerns of the current radiation oncology workforce, evaluate best practices and opportunities for improving quality and safety, and assess what we can predict about the future workforce. Methods and Materials: An online survey was distributed to 35,204 respondents from all segments of the radiation oncology workforce, including radiation oncologists, residents, medical dosimetrists, radiation therapists, medical physicists, nurse practitioners, nurses, physician assistants, and practice managers/administrators. The survey was disseminated by the American Society for Radiation Oncology (ASTRO) together with specialty societies representing other workforce segments. An overview of the methods and global results is presented in this paper. Results: A total of 6765 completed surveys were received, a response rate of 19%, and the final analysis included 5257 respondents. Three-quarters of the radiation oncologists, residents, and physicists who responded were male, in contrast to the other segments in which two-thirds or more were female. The majority of respondents (58%) indicated they were hospital-based, whereas 40% practiced in a free-standing/satellite clinic and 2% in another setting. Among the practices represented in the survey, 21.5% were academic, 25.2% were hospital, and 53.3% were private. A perceived oversupply of professionals relative to demand was reported by the physicist, dosimetrist, and radiation therapist segments. An undersupply was perceived by physician's assistants, nurse practitioners, and nurses. The supply of radiation oncologists and residents was considered balanced. Conclusions: This survey was unique as it attempted to comprehensively assess the radiation oncology workforce by directly surveying each segment. The results suggest there is potential to improve the diversity of the workforce and optimize the supply of the workforce segments. The survey also provides a benchmark for

  9. An Assessment of the Current US Radiation Oncology Workforce: Methodology and Global Results of the American Society for Radiation Oncology 2012 Workforce Study

    International Nuclear Information System (INIS)

    Vichare, Anushree; Washington, Raynard; Patton, Caroline; Arnone, Anna; Olsen, Christine; Fung, Claire Y.; Hopkins, Shane; Pohar, Surjeet

    2013-01-01

    Purpose: To determine the characteristics, needs, and concerns of the current radiation oncology workforce, evaluate best practices and opportunities for improving quality and safety, and assess what we can predict about the future workforce. Methods and Materials: An online survey was distributed to 35,204 respondents from all segments of the radiation oncology workforce, including radiation oncologists, residents, medical dosimetrists, radiation therapists, medical physicists, nurse practitioners, nurses, physician assistants, and practice managers/administrators. The survey was disseminated by the American Society for Radiation Oncology (ASTRO) together with specialty societies representing other workforce segments. An overview of the methods and global results is presented in this paper. Results: A total of 6765 completed surveys were received, a response rate of 19%, and the final analysis included 5257 respondents. Three-quarters of the radiation oncologists, residents, and physicists who responded were male, in contrast to the other segments in which two-thirds or more were female. The majority of respondents (58%) indicated they were hospital-based, whereas 40% practiced in a free-standing/satellite clinic and 2% in another setting. Among the practices represented in the survey, 21.5% were academic, 25.2% were hospital, and 53.3% were private. A perceived oversupply of professionals relative to demand was reported by the physicist, dosimetrist, and radiation therapist segments. An undersupply was perceived by physician's assistants, nurse practitioners, and nurses. The supply of radiation oncologists and residents was considered balanced. Conclusions: This survey was unique as it attempted to comprehensively assess the radiation oncology workforce by directly surveying each segment. The results suggest there is potential to improve the diversity of the workforce and optimize the supply of the workforce segments. The survey also provides a benchmark for

  10. In-beam test of a DIRC Cherenkov radiator with SiPM

    International Nuclear Information System (INIS)

    Kroeck, B.; Hayrapetyan, A.; Foehl, K.; Merle, O.; Dueren, M.; Roy, B.J.; Peters, K.

    2009-01-01

    One of the crucial points for any high energy physics experiment is to obtain a good pion/kaon separation i.e. particle identification (PID). For particles in minimum ionising range, the conventional methods of PID using energy loss and time of flight become insufficient. In such a situation, the measurement of velocity of particles using Cherenkov radiation is an effective tool for PID in combination with momentum information from a tracking detector. The PANDA experiment at FAIR/ GSI plans to use a novel technique for PID with detection of internally reflected Cherenkov (DIRC) light. DIRC uses, in contrast to the conventional gas Cherenkov detectors, a solid radiator and total internal reflection to guide Cherenkov photons onto a detection plane where it will be detected by advanced photon counters. A SiPM is a very new generation photon counter that has several advantages over conventional PMTs. Several prototype Cherenkov detectors with different readout systems are being developed for R and D studies. One such prototype detector with Geiger-APD readout has been built at Giessen and was tested in-beam at GSI. The present report provides details of the very first test measurement

  11. Plutonium recycle test reactor characterization activities and results

    International Nuclear Information System (INIS)

    Cornwell, B.C.

    1997-01-01

    Report contains results of PRTR core and associated structures characterization performed in January and February of 1997. Radiation survey data are presented, along with recommendations for stabilization activities before transitioning to a decontamination and decommissioning function. Recommendations are also made about handling the waste generated by the stabilization activities, and actions suggested by the Decontamination and Decommissioning organization

  12. Radiation safety considerations and compliance within equine veterinary clinics: Results of an Australian survey

    International Nuclear Information System (INIS)

    Surjan, Y.; Ostwald, P.; Milross, C.; Warren-Forward, H.

    2015-01-01

    Objective: To examine current knowledge and the level of compliance of radiation safety principles in equine veterinary clinics within Australia. Method: Surveys were sent to equine veterinary surgeons working in Australia. The survey was delivered both online and in hardcopy format; it comprised 49 questions, 15 of these directly related to radiation safety. The participants were asked about their current and previous use of radiation-producing equipment. Information regarding their level of knowledge and application of radiation safety principles and practice standards was collected and analysed. Results: The use of radiation-producing equipment was evident in 94% of responding clinics (a combination of X-ray, CT and/or Nuclear Medicine Cameras). Of those with radiation-producing equipment, 94% indicated that they hold a radiation licence, 78% had never completed a certified radiation safety course and 19% of participants did not use a personal radiation monitor. In 14% of cases, radiation safety manuals or protocols were not available within clinics. Conclusions: The study has shown that knowledge and application of guidelines as provided by the Code of Practice for Radiation Protection in Veterinary Medicine (2009) is poorly adhered to. The importance of compliance with regulatory requirements is pivotal in minimising occupational exposure to ionising radiation in veterinary medicine, thus there is a need for increased education and training in the area. - Highlights: • Application of the Code of Practice for Veterinary Medicine is poorly adhered to. • Majority of veterinary clinics had not completed certified radiation safety course. • One-fifth of participants did not use personal radiation monitoring. • Increased education and training in area of radiation safety and protection required to generate compliance in clinics

  13. Engineering model cryocooler test results

    International Nuclear Information System (INIS)

    Skimko, M.A.; Stacy, W.D.; McCormick, J.A.

    1992-01-01

    This paper reports that recent testing of diaphragm-defined, Stirling-cycle machines and components has demonstrated cooling performance potential, validated the design code, and confirmed several critical operating characteristics. A breadboard cryocooler was rebuilt and tested from cryogenic to near-ambient cold end temperatures. There was a significant increase in capacity at cryogenic temperatures and the performance results compared will with code predictions at all temperatures. Further testing on a breadboard diaphragm compressor validated the calculated requirement for a minimum axial clearance between diaphragms and mating heads

  14. Irradiation Effects Test Series: Test IE-2. Test results report

    International Nuclear Information System (INIS)

    Allison, C.M.; Croucher, D.W.; Ploger, S.A.; Mehner, A.S.

    1977-08-01

    The report describes the results of a test using four 0.97-m long PWR-type fuel rods with differences in diametral gap and cladding irradiation. The objective of this test was to provide information about the effects of these differences on fuel rod behavior during quasi-equilibrium and film boiling operation. The fuel rods were subjected to a series of preconditioning power cycles of less than 30 kW/m. Rod powers were then increased to 68 kW/m at a coolant mass flux of 4900 kg/s-m 2 . After one hour at 68 kW/m, a power-cooling-mismatch sequence was initiated by a flow reduction at constant power. At a flow of 2550 kg/s-m 2 , the onset of film boiling occurred on one rod, Rod IE-011. An additional flow reduction to 2245 kg/s-m 2 caused the onset of film boiling on the remaining three rods. Data are presented on the behavior of fuel rods during quasiequilibrium and during film boiling operation. The effects of initial gap size, cladding irradiation, rod power cycling, a rapid power increase, and sustained film boiling are discussed. These discussions are based on measured test data, preliminary postirradiation examination results, and comparisons of results with FRAP-T3 computer model calculations

  15. Summary of CCTF test results

    International Nuclear Information System (INIS)

    Iguchi, T.; Murao, Y.; Sugimoto, J.; Akimoto, H.; Okubo, T.; Hojo, T.

    1987-01-01

    Conservatism of current safety analysis was assessed by comparing the predicted result with cylindrical core test facility (CCTF) test result performed at Japan Atomic Energy Research Institute. WREM code was selected for the assessment. The overall conservatism of the WREM code on the peak clad temperature prediction was confirmed against CCTF evaluation model (EM) test which simulated the typical initial and boundary conditions in the safety evaluation analysis. WREM code predicted the reasonable core boundary conditions and the conservatism of the code came mainly from core calculation. The conservatism of the WREM code against CCTF data could be attributed to the following three points: (1) no horizontal mixing assumption between subchannels at each elevation; (2) no modeling on heat transfer enhancement caused by the radial core power profile; and (3) conservative heat transfer correlations in the code

  16. Radiation protection in Bolivia

    International Nuclear Information System (INIS)

    Miranda Cuadros, A.A.

    2001-01-01

    Radiation protection in Bolivia has gone through a number of stages. Initially, in the 1970s, the focus was mainly on the analysis of environmental sources resulting from the nuclear tests carried out by France in the Pacific Ocean. Subsequently, the focus switched somewhat to radiation protection in connection with the mining of uranium and in the area of public health. During the third stage, radiation protection in other areas became important as the use of radiation sources was introduced. Finally, during the present -- fourth -- stage, radiation protection regulations are being introduced and mechanisms for the control of radiation sources are being established. (author)

  17. Complete analytic results for radiative-recoil corrections to ground-state muonium hyperfine splitting

    International Nuclear Information System (INIS)

    Karshenboim, S.G.; Shelyuto, V.A.; Eides, M.E.

    1988-01-01

    Analytic expressions are obtained for radiative corrections to the hyperfine splitting related to the muon line. The corresponding contribution amounts to (Z 2 a) (Za) (m/M) (9/2 ζ(3) - 3π 2 ln 2 + 39/8) in units of the Fermi hyperfine splitting energy. A complete analytic result for all radiative-recoil corrections is also presented

  18. Radiation safety in welding and testing

    International Nuclear Information System (INIS)

    King, B.E.; Malaxos, M.; Hartley, B.M.

    1985-01-01

    There are a number of ways of achieving radiation safety in the workplace. The first is by engineering radiation safety into the equipment, providing shielded rooms and safety interlocks. The second is by following safe working procedures. The National Health and Medical Research Council's Code of practice for the control and safe handling of sealed radioactive sources used in industrial radiography (1968) sets out the standards which must be met by equipment to be used in industrial radiography

  19. Ion chambers compliance results of Brazilian radiation therapy facilities.

    Science.gov (United States)

    Joana, G; Salata, C; Leal, P; Vasconcelos, R; Couto, N do; Teixeira, F C; Soares, A D; Santini, E S; Gonçalves, M

    2018-03-01

    The Brazilian Nuclear Energy Commission (cnen) has been making a constant effort to keep up to date with international standards and national needs to strengthen the status of radiological protection of the country. The guidelines related to radiation therapy facilities have been revised in the last five years in order to take into consideration the most relevant aspects of the growing technology as well as to mitigate the accidents or incidents observed in practice. Hence, clinical dosimeters have gained special importance in this matter. In the present work, we discuss the effectiveness of regulation and inspections to the enforcement of instrument calibration accuracy for the improvement of patient dosimetry and quality control. As a result, we observed that the number of calibrated instruments, mainly well chambers, is increasing each year. The same behavior is observed for instruments employed in technologically advanced radiation treatments such as intensity modulated radiotherapy, volumetric therapy and stereotatic radiosurgery. We ascribe this behavior to the new regulation.

  20. Radiation therapy improves survival in rectal small cell cancer - Analysis of Surveillance Epidemiology and End Results (SEER) data.

    Science.gov (United States)

    Modrek, Aram S; Hsu, Howard C; Leichman, Cynthia G; Du, Kevin L

    2015-04-24

    Small cell carcinoma of the rectum is a rare neoplasm with scant literature to guide treatment. We used the Surveillance Epidemiology and End Results (SEER) database to investigate the role of radiation therapy in the treatment of this cancer. The SEER database (National Cancer Institute) was queried for locoregional cases of small cell rectal cancer. Years of diagnosis were limited to 1988-2010 (most recent available) to reduce variability in staging criteria or longitudinal changes in surgery and radiation techniques. Two month conditional survival was applied to minimize bias by excluding patients who did not survive long enough to receive cancer-directed therapy. Patient demographics between the RT and No_RT groups were compared using Pearson Chi-Square tests. Overall survival was compared between patients who received radiotherapy (RT, n = 43) and those who did not (No_RT, n = 28) using the Kaplan-Meier method. Multivariate Cox proportional hazards model was used to evaluate important covariates. Median survival was significantly longer for patients who received radiation compared to those who were not treated with radiation; 26 mo vs. 8 mo, respectively (log-rank P = 0.009). We also noted a higher 1-year overall survival rate for those who received radiation (71.1% vs. 37.8%). Unadjusted hazard ratio for death (HR) was 0.495 with the use of radiation (95% CI 0.286-0.858). Among surgery, radiotherapy, sex and age at diagnosis, radiation therapy was the only significant factor for overall survival with a multivariate HR for death of 0.393 (95% CI 0.206-0.750, P = 0.005). Using SEER data, we have identified a significant survival advantage with the use of radiation therapy in the setting of rectal small cell carcinoma. Limitations of the SEER data apply to this study, particularly the lack of information on chemotherapy usage. Our findings strongly support the use of radiation therapy for patients with locoregional small cell rectal cancer.

  1. Simulating Large Area, High Intensity AM0 Illumination – Test Results from Bepicolombo and Solar Orbiter Qualification

    Directory of Open Access Journals (Sweden)

    Oberhüttinger C.

    2017-01-01

    Specifically, the following topics will be treated. Different methods like electrical performance, thermo-optical and external quantum efficiency measurements have been used to characterize the behaviour of the solar cells after illumination under these conditions. A special focus has been put on the electrical performance. A comparison to other solar cell qualification tests under solely UV radiation has been undertaken. The results have also been compared to a theoretical model. However, the paper will not cover only characterization results but will also give some insight in challenges experienced during the test execution itself. Deviating from other solar cell qualification tests, a representatively equipped photovoltaic assembly on carbon fibre reinforced cyanate has also been included. On these coupon segments, solar cell assemblies connected to shunt diodes and placed next to optical surface reflectors have been exposed to AM0 illumination to qualify the solar cells including their surroundings which therefore covers also contamination effects. Last but not least, first results from the Solar Orbiter qualification are presented. This test with additional 1000 hours and increased intensity has been completed recently.

  2. Climax granite test results

    Energy Technology Data Exchange (ETDEWEB)

    Ramspott, L.D.

    1980-01-15

    The Lawrence Livermore Laboratory (LLL), as part of the Nevada Nuclear Waste Storage Investigations (NNWSI) program, is carrying out in situ rock mechanics testing in the Climax granitic stock at the Nevada Test Site (NTS). This summary addresses only those field data taken to date that address thermomechanical modeling for a hard-rock repository. The results to be discussed include thermal measurements in a heater test that was conducted from October 1977 through July 1978, and stress and displacement measurements made during and after excavation of the canister storage drift for the Spent Fuel Test (SFT) in the Climax granite. Associated laboratory and field measurements are summarized. The rock temperature for a given applied heat load at a point in time and space can be adequately modeled with simple analytic calculations involving superposition and integration of numerous point source solutions. The input, for locations beyond about a meter from the source, can be a constant thermal conductivity and diffusivity. The value of thermal conductivity required to match the field data is as much as 25% different from laboratory-measured values. Therefore, unless we come to understand the mechanisms for this difference, a simple in situ test will be required to obtain a value for final repository design. Some sensitivity calculations have shown that the temperature field is about ten times more sensitive to conductivity than to diffusivity under the test conditions. The orthogonal array was designed to detect anisotropy. After considering all error sources, anisotropic efforts in the thermal field were less than 5 to 10%.

  3. Pilot-scale decontamination solution test results HGTP-93-0702-02

    International Nuclear Information System (INIS)

    Clemmer, R.G.; Allen, R.P.; Bagaasen, L.M.; Fetrow, L.K.

    1993-05-01

    Decontamination solution testing constitutes a task of the Hanford Grout Technology Program (HGTP) at Pacific Northwest Laboratory (PNL). The HGTP provides technical support to the Westinghouse Hanford Company (WHC) Grout Disposal Program. Cementitious grout has been identified as the waste form for low-level radioactive waste. Grout processing equipment, including mixers, pumps, and piping, will require periodic maintenance. Decontamination of components is needed to reduce radiation dose to maintenance workers. The purpose of this work was to develop and test methods for decontaminating grout processing equipment. The proposed method of decontamination is to use a mild chemical solution, such as a 6 N citric acid to dissolve the grout. The method should effectively remove grout without causing degradation of grout processing equipment

  4. Forecasting of Radiation Belts: Results From the PROGRESS Project.

    Science.gov (United States)

    Balikhin, M. A.; Arber, T. D.; Ganushkina, N. Y.; Walker, S. N.

    2017-12-01

    Forecasting of Radiation Belts: Results from the PROGRESS Project. The overall goal of the PROGRESS project, funded in frame of EU Horizon2020 programme, is to combine first principles based models with the systems science methodologies to achieve reliable forecasts of the geo-space particle radiation environment.The PROGRESS incorporates three themes : The propagation of the solar wind to L1, Forecast of geomagnetic indices, and forecast of fluxes of energetic electrons within the magnetosphere. One of the important aspects of the PROGRESS project is the development of statistical wave models for magnetospheric waves that affect the dynamics of energetic electrons such as lower band chorus, hiss and equatorial noise. The error reduction ratio (ERR) concept has been used to optimise the set of solar wind and geomagnetic parameters for organisation of statistical wave models for these emissions. The resulting sets of parameters and statistical wave models will be presented and discussed. However the ERR analysis also indicates that the combination of solar wind and geomagnetic parameters accounts for only part of the variance of the emissions under investigation (lower band chorus, hiss and equatorial noise). In addition, advances in the forecast of fluxes of energetic electrons, exploiting empirical models and the first principles IMPTAM model achieved by the PROGRESS project is presented.

  5. How Radiation Oncologists Would Disclose Errors: Results of a Survey of Radiation Oncologists and Trainees

    International Nuclear Information System (INIS)

    Evans, Suzanne B.; Yu, James B.; Chagpar, Anees

    2012-01-01

    Purpose: To analyze error disclosure attitudes of radiation oncologists and to correlate error disclosure beliefs with survey-assessed disclosure behavior. Methods and Materials: With institutional review board exemption, an anonymous online survey was devised. An email invitation was sent to radiation oncologists (American Society for Radiation Oncology [ASTRO] gold medal winners, program directors and chair persons of academic institutions, and former ASTRO lecturers) and residents. A disclosure score was calculated based on the number or full, partial, or no disclosure responses chosen to the vignette-based questions, and correlation was attempted with attitudes toward error disclosure. Results: The survey received 176 responses: 94.8% of respondents considered themselves more likely to disclose in the setting of a serious medical error; 72.7% of respondents did not feel it mattered who was responsible for the error in deciding to disclose, and 3.9% felt more likely to disclose if someone else was responsible; 38.0% of respondents felt that disclosure increased the likelihood of a lawsuit, and 32.4% felt disclosure decreased the likelihood of lawsuit; 71.6% of respondents felt near misses should not be disclosed; 51.7% thought that minor errors should not be disclosed; 64.7% viewed disclosure as an opportunity for forgiveness from the patient; and 44.6% considered the patient's level of confidence in them to be a factor in disclosure. For a scenario that could be considerable, a non-harmful error, 78.9% of respondents would not contact the family. Respondents with high disclosure scores were more likely to feel that disclosure was an opportunity for forgiveness (P=.003) and to have never seen major medical errors (P=.004). Conclusions: The surveyed radiation oncologists chose to respond with full disclosure at a high rate, although ideal disclosure practices were not uniformly adhered to beyond the initial decision to disclose the occurrence of the error.

  6. Abnormal Cervical Cancer Screening Test Results

    Science.gov (United States)

    ... AQ FREQUENTLY ASKED QUESTIONS FAQ187 GYNECOLOGIC PROBLEMS Abnormal Cervical Cancer Screening Test Results • What is cervical cancer screening? • What causes abnormal cervical cancer screening test ...

  7. Radiation tests on service electronics for future multi TeV detectors

    International Nuclear Information System (INIS)

    Larsen, H.; Schoenbacher, H.; Massam, T.; Wulf, F.

    1993-01-01

    Irradiation tests of a number of essential components for use in the service electronics of the Leading Proton Spectrometer (LPS) have been undertaken. The components are simple medium-scale integrated circuits such as Transistor Transistor Logic (TTL) buffers from the Advanced Low-power Schottky (ALS), Low-power Schottky (LS), and Fast (F) families, optocouplers, and balanced line drivers and receivers. More complex circuits, such as a Fuse Programmable Array Logic chip, programmed as a 6-bit counter, and a complete switched-mode power supply unit were also tested. Further, monolithic voltage regulators with an output potential of 5 V, and 10 MHz quartz oscillator hybrids were tested. The different radiation fields were X-rays (80 keV), 60 Co gamma rays, electrons (2.5 MeV), and a high-energy proton accelerator environment. Depending on the device degradation, the maximum dose was up to 0.8 MGy. It is shown that the simple choice of circuit family can achieve a hardness level of nearly 1 MGy(Si), provided that one is prepared to make some sacrifices in power consumption, and in speed. It has been found that this radiation hardness can be reached with LS technology. The maximum level of about 1 MGy(Si) was obtained with 2.5 MeV electrons, which is equivalent to a 1 MeV neutron fluence of the order of 6x10 13 n/cm 2 . (orig.)

  8. On the possible role of thermal radiation in containment thermal–hydraulics experiments by the example of CFD analysis of TOSQAN T114 air–He test

    Energy Technology Data Exchange (ETDEWEB)

    Filippov, A.S.; Grigoryev, S.Yu. [Nuclear Safety Institute of the Russian Academy of Sciences, Moscow (Russian Federation); Moscow Institute of Physics and Technology (Russian Federation); Tarasov, O.V. [Nuclear Safety Institute of the Russian Academy of Sciences, Moscow (Russian Federation)

    2016-12-15

    Highlights: • Neglecting by heat radiation in simulation of containment tests may cause discrepancies. • To show that, heat exchange in T114 air-helium test was analyzed in different ways. • Effect of thermal radiation on local temperature was numerically obtained in air with ∼1% steam content. • Model of gas-structure heat exchange in containment should include heat radiation. - Abstract: One of the experiments of ERCOSAM–SAMARA (E–S) projects (TOSQAN T114) is examined from the viewpoint of the radiative heat transfer (RHT) contribution to the overall heat exchange. E–S projects and T114 test were focused on investigation of light gas stratification in severe accident containment atmosphere and stratification break-up after the activation of mitigation systems. The first from two phases of T114 test is considered during which helium is quasistatically injected into the upper part of the TOSQAN vessel having isothermal walls and initially filled by air. The developing free convection removes most of the heat acquired, but not all. Thus stable local deviations in calculated temperatures were obtained in simulations that were interpreted as the deficiencies of the physical heat-transfer model. The modeling of RHT was included in full CFD simulation that resulted in a better agreement in local temperatures. The results of comparative calculations performed without/with RHT modeling are described in the paper. The RHT model implemented in the used CFD code (ANSYS FLUENT) was tested on known analytical solutions. The RHT contribution in T114 test was also estimated analytically to demonstrate independently that it may be noticeable in this experiment. The same estimations may be valid for stagnant zones of severe accident containment. All that shows the need in further detailing of the role of RHT in gas-structure heat exchange: as for interpretation of some containment tests performed in pressure vessel as for containment modeling.

  9. Irradiation Effects Test Series: Test IE-3. Test results report. [PWR

    Energy Technology Data Exchange (ETDEWEB)

    Farrar, L. C.; Allison, C. M.; Croucher, D. W.; Ploger, S. A.

    1977-10-01

    The objectives of the test reported were to: (a) determine the behavior of irradiated fuel rods subjected to a rapid power increase during which the possibility of a pellet-cladding mechanical interaction failure is enhanced and (b) determine the behavior of these fuel rods during film boiling following this rapid power increase. Test IE-3 used four 0.97-m long pressurized water reactor type fuel rods fabricated from previously irradiated fuel. The fuel rods were subjected to a preconditioning period, followed by a power ramp to 69 kW/m at a coolant mass flux of 4920 kg/s-m/sup 2/. After a flow reduction to 2120 kg/s-m/sup 2/, film boiling occurred on the fuel rods. One rod failed approximately 45 seconds after the reactor was shut down as a result of cladding embrittlement due to extensive cladding oxidation. Data are presented on the behavior of these irradiated fuel rods during steady-state operation, the power ramp, and film boiling operation. The effects of a power ramp and power ramp rates on pellet-cladding interaction are discussed. Test data are compared with FRAP-T3 computer model calculations and data from a previous Irradiation Effects test in which four irradiated fuel rods of a similar design were tested. Test IE-3 results indicate that the irradiated state of the fuel rods did not significantly affect fuel rod behavior during normal, abnormal (power ramp of 20 kW/m per minute), and accident (film boiling) conditions.

  10. Testbeam and laboratory test results of irradiated 3D CMS pixel detectors

    Energy Technology Data Exchange (ETDEWEB)

    Bubna, Mayur [Purdue University, Department of Physics, West Lafayette, IN 47907-1396 (United States); Purdue University, School of Electrical and Computer Engineering, West Lafayette, IN 47907-1396 (United States); Alagoz, Enver, E-mail: enver.alagoz@cern.ch [Purdue University, Department of Physics, West Lafayette, IN 47907-1396 (United States); Cervantes, Mayra; Krzywda, Alex; Arndt, Kirk [Purdue University, Department of Physics, West Lafayette, IN 47907-1396 (United States); Obertino, Margherita; Solano, Ada [Istituto Nazionale di Fisica Nucleare, Sezione di Torino, 10125 Torino (Italy); Dalla Betta, Gian-Franco [INFN Padova (Gruppo Collegato di Trento) (Italy); Dipartimento di Ingegneria e Scienzadella Informazione, Universitá di Trento, I-38123 Povo di Trento (Italy); Menace, Dario; Moroni, Luigi [Istituto Nazionale di Fisica Nucleare, Sezione di Milano Bicocca (Italy); Universitá degli Studi di Milano Bicocca, 20126 Milano (Italy); Uplegger, Lorenzo; Rivera, Ryan [Fermi National Accelerator Laboratory, Batavia, IL 60510-0500 (United States); Osipenkov, Ilya [Texas A and M University, Department of Physics, College Station, TX 77843-4242 (United States); Andresen, Jeff [Fermi National Accelerator Laboratory, Batavia, IL 60510-0500 (United States); Bolla, Gino; Bortoletto, Daniela [Purdue University, Department of Physics, West Lafayette, IN 47907-1396 (United States); Boscardin, Maurizio [Centro per i Materiali e i Microsistemi Fondazione Bruno Kessler (FBK), Trento, I-38123 Povo di Trento (Italy); Marie Brom, Jean [Strasbourg IPHC, Institut Pluriedisciplinaire Hubert Curien, F-67037 Strasbourg Cedex (France); Brosius, Richard [State University of New York at Buffalo (SUNY), Department of Physics, Buffalo, NY 14260-1500 (United States); Chramowicz, John [Fermi National Accelerator Laboratory, Batavia, IL 60510-0500 (United States); and others

    2013-12-21

    The CMS silicon pixel detector is the tracking device closest to the LHC p–p collisions, which precisely reconstructs the charged particle trajectories. The planar technology used in the current innermost layer of the pixel detector will reach the design limit for radiation hardness at the end of Phase I upgrade and will need to be replaced before the Phase II upgrade in 2020. Due to its unprecedented performance in harsh radiation environments, 3D silicon technology is under consideration as a possible replacement of planar technology for the High Luminosity-LHC or HL-LHC. 3D silicon detectors are fabricated by the Deep Reactive-Ion-Etching (DRIE) technique which allows p- and n-type electrodes to be processed through the silicon substrate as opposed to being implanted through the silicon surface. The 3D CMS pixel devices presented in this paper were processed at FBK. They were bump bonded to the current CMS pixel readout chip, tested in the laboratory, and testbeams carried out at FNAL with the proton beam of 120 GeV/c. In this paper we present the laboratory and beam test results for the irradiated 3D CMS pixel devices. -- Highlights: •Pre-irradiation and post-irradiation electrical properties of 3D sensors and 3D diodes from various FBK production batches were measured and analyzed. •I–T measurements of gamma irradiated diodes were analyzed to understand leakage current generation mechanism in 3D diodes. •Laboratory measurements: signal to noise ratio and charge collection efficiency of 3D sensors before and after irradiation. •Testbeam measurements: pre- and post-irradiation pixel cell efficiency and position resolution of 3D sensors.

  11. Radiation testing of thick-wall objects using a linear accelerator or Co-60

    International Nuclear Information System (INIS)

    Depending on the energy required, a 60 Co source or various types of betatrons and linear accelerators may be used for radiation testing of thick-walled metal parts. While 60 Co sources are easily transported, accelerators are not, but a transportable linear accelerator is described

  12. An Autonomous System for Experimental Evolution of Microbial Cultures: Test Results Using Ultraviolet-C Radiation and Escherichia Coli.

    Science.gov (United States)

    Ouandji, Cynthia; Wang, Jonathan; Arismendi, Dillon; Lee, Alonzo; Blaich, Justin; Gentry, Diana

    2017-01-01

    At its core, the field of microbial experimental evolution seeks to elucidate the natural laws governing the history of microbial life by understanding its underlying driving mechanisms. However, observing evolution in nature is complex, as environmental conditions are difficult to control. Laboratory-based experiments for observing population evolution provide more control, but manually culturing and studying multiple generations of microorganisms can be time consuming, labor intensive, and prone to inconsistency. We have constructed a prototype, closed system device that automates the process of directed evolution experiments in microorganisms. It is compatible with any liquid microbial culture, including polycultures and field samples, provides flow control and adjustable agitation, continuously monitors optical density (OD), and can dynamically control environmental pressures such as ultraviolet-C (UV-C) radiation and temperature. Here, the results of the prototype are compared to iterative exposure and survival assays conducted using a traditional hood, UV-C lamp, and shutter system.

  13. LHC IR Upgrade Nb-Ti, 120mm Aperture Model Quadrupole Test Results at 1.8K

    CERN Document Server

    Kirby, G A; Bajko, M; Datskov, V I; Durante, M; Fessia, P; Feuvrier, J; Guinchard, M; Giloux, C; Granieri, P P; Manil, P; Perez, J C; Ravaioli, E; Rifflet, J M; Russenschuck, S; Sahner, T; Segreti, M; Todesco, E; Willering, G

    2014-01-01

    Over the last five years, the model MQXC quadruple, a 120 mm aperture, 120 T/m, 1.8 m long, Nb-Ti version of the LHC insertion upgrade (due in 2021), has been developed at CERN. The magnet incorporates several novel concepts to extract high levels of heat flux and provide high quality field harmonics throughout the full operating current range. Existing LHC-dipole cable with new, open cable and ground insulation was used. Two, nominally identical 1.8 m long magnets were built and tested at 1.8 K at the CERN SM18 test facility. This paper compares in detail the two magnet tests and presents: quench performance, internal stresses, heat extraction simulating radiation loading in the superconducting coils, and quench protection measurements. The first set of tests highlighted the conflict between high magnet cooling capability and quench protection. The second magnet had additional instrumentation to investigate further this phenomenon. Finally we present test results from a new type of superconducting magnet pro...

  14. Results obtained with the passive radiation detectors in the ICCHIBAN-4 experiment

    International Nuclear Information System (INIS)

    Bilski, P.; Horwacik, T.

    2005-05-01

    In frame of the InterComparison of Cosmic rays with Heavy Ions Beams at NIRS (ICCHIBAN) organized at the HIMAC accelerator in Chiba several types of the thermoluminescent detectors (TLD), as well as CR-39 track detectors, were exposed. Four different types of TLDs were used: MTS-7 ( 7 LiF:Mg,Ti), MTS-6 ( 6 LiF:Mg,Ti), MCP-7 ( 7 LiF:Mg,Cu,P) and MTT-7 ( 7 LiF:Mg,Ti with changed activator composition. All TLDs were manufactured at the Institute of Nuclear Physics (INP) in Cracow. The detectors were irradiated with various doses of He, C, Ne and Fe ions. Part of exposures were done in unknown conditions, to test measuring capabilities of the detectors. For analyses of these results, the method of obtaining information on ionisation density of an unknown radiation field, which is based on ratios of responses of different LiF detectors, was successfully used. (author)

  15. Silicon Photo-Multiplier Radiation Hardness Tests with a White Neutron Beam

    International Nuclear Information System (INIS)

    Montanari, A.; Tosi, N.; Pietropaolo, A.; Andreotti, M.; Baldini, W.; Calabrese, R.; Cibinetto, G.; Luppi, E.; Cotta Ramusino, A.; Malaguti, R.; Santoro, V.; Tellarini, G.; Tomassetti, L.; De Donato, C.; Reali, E.

    2013-06-01

    We report radiation hardness tests performed, with a white neutron beam, at the Geel Electron Linear Accelerator in Belgium on silicon Photo-Multipliers. These are semiconductor photon detectors made of a square matrix of Geiger-Mode Avalanche photo-diodes on a silicon substrate. Several samples from different manufacturers have been irradiated integrating up to about 6.2 x 10 9 1-MeV-equivalent neutrons per cm 2 . (authors)

  16. Incidents with hazardous radiation sources

    International Nuclear Information System (INIS)

    Schoenhacker, Stefan

    2016-01-01

    Incidents with hazardous radiation sources can occur in any country, even those without nuclear facilities. Preparedness for such incidents is supposed to fulfill globally agreed minimum standards. Incidents are categorized in incidents with licensed handling of radiation sources as for material testing, transport accidents of hazardous radiation sources, incidents with radionuclide batteries, incidents with satellites containing radioactive inventory, incidents wit not licensed handling of illegally acquired hazardous radiation sources. The emergency planning in Austria includes a differentiation according to the consequences: incidents with release of radioactive materials resulting in restricted contamination, incidents with release of radioactive materials resulting in local contamination, and incidents with the hazard of e@nhanced exposure due to the radiation source.

  17. Environmental Radiation Monitoring In The Chernobyl Exclusion Zone - History And Results 25 Years After

    International Nuclear Information System (INIS)

    Farfan, E.; Jannik, T.

    2011-01-01

    This article describes results of the radiation environmental monitoring performed in the Chernobyl Exclusion Zone (ChEZ) during the period following the 1986 Chernobyl Nuclear Power Plant accident. This article presents a brief overview of five comprehensive reports generated under Contract No. DE-AC09-96SR18500 (Washington Savannah River Company LLC, Subcontract No. AC55559N, SOW No. ON8778) and summarizes characteristics of the ChEZ and its post-accident status and the history of development of the radiation monitoring research in the ChEZ is described. This article addresses characteristics of the radiation monitoring in the ChEZ, its major goals and objectives, and changes of these goals and objectives in the course of time, depending on the tasks associated with the phase of mitigation of the ChNPP accident consequences. The results of the radiation monitoring in the ChEZ during the last 25 years are also provided.

  18. ENVIRONMENTAL RADIATION MONITORING IN THE CHERNOBYL EXCLUSION ZONE - HISTORY AND RESULTS 25 YEARS AFTER

    Energy Technology Data Exchange (ETDEWEB)

    Farfan, E.; Jannik, T.

    2011-10-01

    This article describes results of the radiation environmental monitoring performed in the Chernobyl Exclusion Zone (ChEZ) during the period following the 1986 Chernobyl Nuclear Power Plant accident. This article presents a brief overview of five comprehensive reports generated under Contract No. DE-AC09-96SR18500 (Washington Savannah River Company LLC, Subcontract No. AC55559N, SOW No. ON8778) and summarizes characteristics of the ChEZ and its post-accident status and the history of development of the radiation monitoring research in the ChEZ is described. This article addresses characteristics of the radiation monitoring in the ChEZ, its major goals and objectives, and changes of these goals and objectives in the course of time, depending on the tasks associated with the phase of mitigation of the ChNPP accident consequences. The results of the radiation monitoring in the ChEZ during the last 25 years are also provided.

  19. Preliminary experimental results of tungsten wire-array Z-pinches on primary test stand

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Xian-Bin; Zhou, Shao-Tong; Dan, Jia-Kun; Ren, Xiao-Dong, E-mail: amosrxd@163.com; Wang, Kun-Lun; Zhang, Si-Qun; Li, Jing; Xu, Qiang; Cai, Hong-Chun; Duan, Shu-Chao; Ouyang, Kai; Chen, Guang-Hua; Ji, Ce; Wei, Bing; Feng, Shu-Ping; Wang, Meng; Xie, Wei-Ping; Deng, Jian-Jun [Key Laboratory of Pulsed Power, Institute of Fluid Physics, China Academy of Engineering Physics, P.O. Box 919-108, Mianyang, Sichuan 621999 (China); Zhou, Xiu-Wen; Yang, Yi [Research Center of Laser Fusion, China Academy of Engineering Physics, P.O. Box 919-987, Mianyang, Sichuan 621999 (China)

    2015-07-15

    The Primary Test Stand (PTS) developed at the China Academy of Engineering Physics is a 20 TW pulsed power driver, which can deliver a ∼10 MA, 70 ns rise-time (10%–90%) current to a short-circuit load and has important applications in Z-pinch driven inertial confinement fusion and high energy density physics. Preliminary results of tungsten wire-array Z-pinch experiments on PTS are presented. The load geometries investigated include 15-mm-tall cylindrical single and nested arrays with diameter ranging from 13 mm to 30 mm, consisting of 132–300 tungsten wires with 5–10 μm in diameter. Multiple diagnostics were fielded to characterize the x-ray radiation from wire-array Z pinches. The x-ray peak power (∼50 TW) and total radiated energy (∼500 kJ) were obtained from a single 20-mm-diam array with 80-ns stagnation time. The highest x-ray peak power up to 80 TW with 2.4 ns FWHM was achieved by using a nested array with 20-mm outer diameter, and the total x-ray energy from the nested array is comparable to that of single array. Implosion velocity estimated from the time-resolved image measurement exceeds 30 cm/μs. The detailed experimental results and other findings are presented and discussed.

  20. Origin of ΔNeff as a result of an interaction between dark radiation and dark matter

    International Nuclear Information System (INIS)

    Bjaelde, Ole Eggers; Das, Subinoy; Moss, Adam

    2012-01-01

    Results from the Wilkinson Microwave Anisotropy Probe (WMAP), Atacama Cosmology Telescope (ACT) and recently from the South Pole Telescope (SPT) have indicated the possible existence of an extra radiation component in addition to the well known three neutrino species predicted by the Standard Model of particle physics. In this paper, we explore the possibility of the apparent extra dark radiation being linked directly to the physics of cold dark matter (CDM). In particular, we consider a generic scenario where dark radiation, as a result of an interaction, is produced directly by a fraction of the dark matter density effectively decaying into dark radiation. At an early epoch when the dark matter density is negligible, as an obvious consequence, the density of dark radiation is also very small. As the Universe approaches matter radiation equality, the dark matter density starts to dominate thereby increasing the content of dark radiation and changing the expansion rate of the Universe. As this increase in dark radiation content happens naturally after Big Bang Nucleosynthesis (BBN), it can relax the possible tension with lower values of radiation degrees of freedom measured from light element abundances compared to that of the CMB. We numerically confront this scenario with WMAP+ACT and WMAP+SPT data and derive an upper limit on the allowed fraction of dark matter decaying into dark radiation

  1. Irradiation test of component for radiation-resistant small sized motor

    International Nuclear Information System (INIS)

    Nakamichi, M.; Ishitsuka, E.; Shimakawa, S.; Kan, S.

    2009-01-01

    A small-sized motor with a resistance to radiation was developed. This motor has been able to operate at a gamma-ray dose of a value 700 times as high as the specification of a commercial motor. The present work describes results of post-irradiation examinations (PIEs) to evaluate effects of neutron irradiation on the lifetime of some major components of the motor such as a bearing, a magnet and a fixation agent for a field coil wire. It became clear from the results of PIEs that the radiation-resistance dose of the motor using a Sm-Co magnet will be expected to be one order of magnitude higher than that of the motor using a Nb-Fe-B magnet.

  2. Development of flame retardant, radiation resistant insulating materials

    Energy Technology Data Exchange (ETDEWEB)

    Hagiwara, M.

    1984-01-01

    On the cables used for nuclear power stations, in particular those ranked as IE class, flame retardation test, simulated LOCA environment test, radiation resistance test and so on are imposed. The results of the evaluation of performance by these tests largely depend on the insulating materials mainly made of polymers. Ethylene propylene copolymer rubber has been widely used as cable insulator because of its electrical characteristics, workability, economy and relatively good radiation resistance, but it is combustible, therefore, in the practical use, it is necessary to make it fire resistant. The author et al. have advanced the research on the molecular design of new fire retarding materials, and successfully developed acenaphthylene bromide condensate, which is not only fire resistant but also effective for improving radiation resistance. The condition of flame retardant, radiation resistant auxiliary agents is explained, and there are additive type and reaction type in fire retarding materials. The synthesis of acenaphthylene bromide condensate and its effect of giving flame retardant and radiation resistant properties are reported. The characteristics of the cables insulated with the flame retardant ethylene propylene rubber containing acenaphthylene bromide condensate were tested, and the results are shown. (Kako, I.).

  3. Radiation hardened COTS-based 32-bit microprocessor

    International Nuclear Information System (INIS)

    Haddad, N.; Brown, R.; Cronauer, T.; Phan, H.

    1999-01-01

    A high performance radiation hardened 32-bit RISC microprocessor based upon a commercial single chip CPU has been developed. This paper presents the features of radiation hardened microprocessor, the methods used to radiation harden this device, the results of radiation testing, and shows that the RAD6000 is well-suited for the vast majority of space applications. (authors)

  4. Health status of radiation exposed residents living near the Semipalatinsk Nuclear Test Site based on health assessment by interview.

    Science.gov (United States)

    Hirabayashi, Kyoko; Kawano, Noriyuki; Ohtaki, Megu; Harada, Yuka; Harada, Hironori; Muldagaliyev, Talgat; Apsalikov, Kazbek; Hoshi, Masaharu

    2008-03-01

    The purpose of the present paper is to examine the aftereffects of radiation exposure on residents of villages near the Semipalatinsk Nuclear Test Site (SNTS) in Kazakhstan. Our Hiroshima University (Japan) research team began field research in 2002 by means of health assessments conducted via interviews. We focus on persons who responded to questions concerning their medical conditions and symptoms. In this paper, we summarize and analyze, using multiple linear logistic regression analysis, the answers obtained by questionnaire survey. The results show: (1) 31% of the residents reported that they felt bad or were in very poor health. (2) Residents living in villages having higher radiation levels were more likely to report having poor or very poor health, minor complaints such as loss of sleep, headaches, nighttime sweating and swollen arms or legs, and the need for nursing care in performing activities of daily living. (3) Symptoms reported by over 40% of the respondents included high blood pressure, heart disease and arthralgia/ lower back pain/ arthritis. Our results suggest that radiation exposure in the Semipalatinsk area is one of the causes of poor health in general among residents. There is also a possibility that radiation exposure has influenced the incidence of some specific medical conditions.

  5. Health status of radiation exposed residents living near the Semipalatinsk Nuclear Test Site based on health assessment by interview

    International Nuclear Information System (INIS)

    Hirabayashi, Kyoko; Kawano, Noriyuki; Ohtaki, Megu; Harada, Yuka; Hoshi, Masaharu; Hadara, Hironori; Muldagaliyev, Talgat; Apsalikov, Kazbek

    2008-01-01

    The purpose of the present paper is to examine the aftereffects of radiation exposure on residents of villages near the Semipalatinsk Nuclear Test Site (SNTS) in Kazakhstan. Our Hiroshima University (Japan) research team began field research in 2002 by means of health assessments conducted via interviews. We focus on persons who responded to questions concerning their medical conditions and symptoms. In this paper, we summarize and analyze, using multiple linear logistic regression analysis, the answers obtained by questionnaire survey. The results show: 31% of the residents reported that they felt bad or were in very poor health. Residents living in villages having higher radiation levels were more likely to report having poor or very poor health, minor complaints such as loss of sleep, headaches, nighttime sweating and swollen arms or legs, and the need for nursing care in performing activities of daily living. Symptoms reported by over 40% of the respondents included high blood pressure, heart disease and arthralgia/lower back pain/arthritis. Our results suggest that radiation exposure in the Semipalatinsk area is one of the causes of poor health in general among residents. There is also a possibility that radiation exposure has influenced the incidence of some specific medical conditions. (author)

  6. BWR Full Integral Simulation Test (FIST). Phase I test results

    International Nuclear Information System (INIS)

    Hwang, W.S.; Alamgir, M.; Sutherland, W.A.

    1984-09-01

    A new full height BWR system simulator has been built under the Full-Integral-Simulation-Test (FIST) program to investigate the system responses to various transients. The test program consists of two test phases. This report provides a summary, discussions, highlights and conclusions of the FIST Phase I tests. Eight matrix tests were conducted in the FIST Phase I. These tests have investigated the large break, small break and steamline break LOCA's, as well as natural circulation and power transients. Results and governing phenomena of each test have been evaluated and discussed in detail in this report. One of the FIST program objectives is to assess the TRAC code by comparisons with test data. Two pretest predictions made with TRACB02 are presented and compared with test data in this report

  7. Test beam results of LHCb scintillating fibre tracker prototypes

    Energy Technology Data Exchange (ETDEWEB)

    Bachmann, Sebastian; Comerma, Albert; Gerick, David; Hansmann-Menzemer, Stephanie; Kecke, Matthieu; Leverington, Blake; Mazorra de Cos, Jose; Mitzel, Dominik; Neuner, Max; Uwer, Ulrich; Han, Xiaoxue [Physikalisches Institut, Universitaet Heidelberg (Germany); Collaboration: LHCb-Collaboration

    2016-07-01

    During the Long Shutdown 2 of the LHC, the LHCb detector will undergo a major upgrade to meet the challenges of running at a higher luminosity. The current Inner and Outer Tracking system will not be sufficient to deal with the envisaged increased detector occupancy and higher radiation levels and will be replaced by a single tracking detector based on 0.250 mm diameter plastic scintillating fibres. The fibres are wound to multilayer ribbons 2.4 m long and read out by 128 channel silicon photomultiplier arrays. The Scintillating Fibre (SciFi) tracker will cover a total active area of 360 m{sup 2}, arranged in 12 layers. The performances of prototype modules having 6 and 8 layers of fibre have been tested at the SPS at CERN. This talk focuses on basic properties of the prototype modules such as spatial resolution, single hit efficiency and light yield measured during the test beam campaigns in 2015.

  8. Airborne mapping of radioactive contamination. Results from a test in Finland, RESUME95

    Energy Technology Data Exchange (ETDEWEB)

    Roenning, S.; Smethurst, M.A. [Geological Survey of Norway (Norway)

    1997-12-31

    The Geological Survey of Norway participated in the exercise RESUME95 (Rapid Environmental Surveying Using Mobile Equipment 95) in Finland, during August 1995. The purpose of the exercise was to 1) test preparedness in the Nordic countries for accidents involving the release and dispersal of radioactive material, 2) compare results from the different teams participating in the exercise, 3) establish routines for the exchange of data and 4) investigate the possibility of international assistance in the event of nuclear accidents. The Geological Survey of Norway carried out a survey over three test areas (area I, II and III). All three areas were contaminated with man made radionuclides in the days following the Chernobyl nuclear reactor accident. The Cesium-137 contamination level was reported to be about 50 kBq/m{sup 2} in area I, and this area was used for calibration. In area II mapping of Cesium-137 ground concentration was carried out. Detection of hidden artificial radiation sources were the main purpose in area III. This report describes the exercise - RESUME95, field operations, calibration, mapping of Cesium-137 ground concentration and detection of hidden point sources. Results are presented as colour maps. (au).

  9. Airborne mapping of radioactive contamination. Results from a test in Finland, RESUME95

    Energy Technology Data Exchange (ETDEWEB)

    Roenning, S; Smethurst, M A [Geological Survey of Norway (Norway)

    1998-12-31

    The Geological Survey of Norway participated in the exercise RESUME95 (Rapid Environmental Surveying Using Mobile Equipment 95) in Finland, during August 1995. The purpose of the exercise was to 1) test preparedness in the Nordic countries for accidents involving the release and dispersal of radioactive material, 2) compare results from the different teams participating in the exercise, 3) establish routines for the exchange of data and 4) investigate the possibility of international assistance in the event of nuclear accidents. The Geological Survey of Norway carried out a survey over three test areas (area I, II and III). All three areas were contaminated with man made radionuclides in the days following the Chernobyl nuclear reactor accident. The Cesium-137 contamination level was reported to be about 50 kBq/m{sup 2} in area I, and this area was used for calibration. In area II mapping of Cesium-137 ground concentration was carried out. Detection of hidden artificial radiation sources were the main purpose in area III. This report describes the exercise - RESUME95, field operations, calibration, mapping of Cesium-137 ground concentration and detection of hidden point sources. Results are presented as colour maps. (au).

  10. On protection of freedom's solar dynamic radiator from the orbital debris environment. Part 2

    International Nuclear Information System (INIS)

    Rhatigan, J.L.

    1992-01-01

    In this paper, recent progress to better understand the environmental threat of micrometeoroid and space debris to the solar dynamic radiator for the Space Station Freedom power system is reported. The objective was to define a design which would perform to survivability requirements over the expected lifetime of the radiator. A previous paper described the approach developed to assess on-orbit survivability of the solar dynamic radiator due to micrometeoroid and space debris impacts. Preliminary analyses were presented to quantify the solar dynamic radiator survivability. These included the type of particle and particle population expected to defeat the radiator bumpering. Results of preliminary hypervelocity impact (HVI) testing performed on radiator panel samples were also presented. This paper presents results of a more extensive test program undertaken to further define the response of the solar dynamic radiator to HVI. Tests were conducted on representative radiator panels (under ambient, nonoperating conditions) over a range of particle size, particle density, impact angle, and impact velocity. Target parameters were also varied. Data indicate that analytical penetration predictions are conservative (i.e., pessimistic) for the specific configuration of the solar dynamic radiator. Test results are used to define more rigorously the solar dynamic radiator reliability with respect to HVI. Test data, analyses, and survivability results are presented

  11. Workers radiation protection. Occupational exposure to ionizing radiations in France: 2016 results

    International Nuclear Information System (INIS)

    2017-06-01

    National results of the individual monitoring of occupational exposure to ionizing radiation are reported for all civilian and military activities subject to authorization or declaration (i.e. medical and veterinary activities, nuclear industry, defence, non-nuclear industry and research), as well as for activities concerned by the enhanced exposure to natural radiation. 372 262 workers within activities subject to authorization or declaration were monitored by passive dosimetry in 2015, which represents an increase by 1.8 % compared to 2015. The average individual dose in 2016 was very close to the value in 2015. Furthermore, 14 218 workers received more than 1 mSv (i.e. the legal dose limit for the public), and 2 703 workers received more than 5 mSv. 1 worker received more than 20 mSv (i.e. the dose limit for the workers in the French regulation). As a result, the collective dose increased from 61.9 to 63.2 man.Sv (2 %), thus reaching the same level as in the years 2009 to 2013. Important differences are noticed according to the occupational activities: the average dose in the medical and veterinary field (which represents 61.2 % of the monitored workers) and that in the research field (3.1 % of the monitored workers) are less than 0.35 mSv; the average doses are higher in the nuclear field and in the non-nuclear industry (representing together 30.5 % of the monitored workers), respectively 1.15 mSv and 1.36 mSv. Concerning internal dosimetry, 279 659 individual examinations have been performed in 2016, 54 % of which are radio-toxicological analysis of excreta and 46 % are direct body counting. In 2016, 5 workers had a committed effective dose greater than or equal to 1 mSv and the maximum dose was 19.4 mSv. Data or trends relative to workers exposed to natural radioactivity are also dealt with in this report (air-crews, personnel subjected to radon exposure). In particular, results of aircrew dosimetry are reported: in 2016, the average individual dose of 19 875

  12. Workers radiation protection. Occupational exposure to ionizing radiations in France: 2015 results

    International Nuclear Information System (INIS)

    2016-06-01

    National results of the individual monitoring of occupational exposure to ionizing radiation are reported for all civilian and military activities subject to authorization or declaration (i.e. medical and veterinary activities, nuclear industry, defence, non-nuclear industry and research), as well as for activities concerned by the enhanced exposure to natural radiation. 365 830 workers within activities subject to authorization or declaration were monitored by passive dosimetry in 2015, which represents an increase by 1.7 % compared to 2014. The average individual dose in 2015 was very close to the value in 2014. Furthermore, 14 138 workers received more than 1 mSv (i.e. the legal dose limit for the public), and 2 606 workers received more than 5 mSv. 2 workers received more than 20 mSv (i.e. the dose limit for the workers in the French regulation). As a result, the collective dose increased from 56.3 to 61.9 man.Sv (10 %), thus reaching the same level as in the years 2009 to 2013. Important differences are noticed according to the occupational activities: the average dose in the medical and veterinary field (which represents 62.4 % of the monitored workers) and that in the research field (3.6 % of the monitored workers) are less than 0.4 mSv; the average doses are higher in the nuclear field and in the non-nuclear industry (representing together 30.1 % of the monitored workers), respectively 1.17 mSv and 1.38 mSv. Concerning internal dosimetry, 279 877 individual examinations have been performed in 2015, 52 % of which are radio-toxicological analysis of excreta and 48 % are direct body counting. In 2015, 2 workers had a committed effective dose greater than or equal to 1 mSv and the maximum dose was 3 mSv. Data or trends relative to workers exposed to natural radioactivity are also dealt with in this report (air crews, personnel subjected to radon exposure). In particular, results of aircrew dosimetry are reported: in 2015, the average individual dose of 19 565

  13. Results of steel containment vessel model test

    International Nuclear Information System (INIS)

    Luk, V.K.; Ludwigsen, J.S.; Hessheimer, M.F.; Komine, Kuniaki; Matsumoto, Tomoyuki; Costello, J.F.

    1998-05-01

    A series of static overpressurization tests of scale models of nuclear containment structures is being conducted by Sandia National Laboratories for the Nuclear Power Engineering Corporation of Japan and the US Nuclear Regulatory Commission. Two tests are being conducted: (1) a test of a model of a steel containment vessel (SCV) and (2) a test of a model of a prestressed concrete containment vessel (PCCV). This paper summarizes the conduct of the high pressure pneumatic test of the SCV model and the results of that test. Results of this test are summarized and are compared with pretest predictions performed by the sponsoring organizations and others who participated in a blind pretest prediction effort. Questions raised by this comparison are identified and plans for posttest analysis are discussed

  14. Ten Year Operating Test Results and Post-Test Analysis of a 1/10 Segment Stirling Sodium Heat Pipe, Phase III

    Science.gov (United States)

    Rosenfeld, John, H; Minnerly, Kenneth, G; Dyson, Christopher, M.

    2012-01-01

    High-temperature heat pipes are being evaluated for use in energy conversion applications such as fuel cells, gas turbine re-combustors, Stirling cycle heat sources; and with the resurgence of space nuclear power both as reactor heat removal elements and as radiator elements. Long operating life and reliable performance are critical requirements for these applications. Accordingly, long-term materials compatibility is being evaluated through the use of high-temperature life test heat pipes. Thermacore, Inc., has carried out a sodium heat pipe 10-year life test to establish long-term operating reliability. Sodium heat pipes have demonstrated favorable materials compatibility and heat transport characteristics at high operating temperatures in air over long time periods. A representative one-tenth segment Stirling Space Power Converter heat pipe with an Inconel 718 envelope and a stainless steel screen wick has operated for over 87,000 hr (10 yr) at nearly 700 C. These life test results have demonstrated the potential for high-temperature heat pipes to serve as reliable energy conversion system components for power applications that require long operating lifetime with high reliability. Detailed design specifications, operating history, and post-test analysis of the heat pipe and sodium working fluid are described.

  15. Niche evolution and adaptive radiation: Testing the order of trait divergence

    Science.gov (United States)

    Ackerly, D.D.; Schwilk, D.W.; Webb, C.O.

    2006-01-01

    In the course of an adaptive radiation, the evolution of niche parameters is of particular interest for understanding modes of speciation and the consequences for coexistence of related species within communities. We pose a general question: In the course of an evolutionary radiation, do traits related to within-community niche differences (?? niche) evolve before or after differentiation of macrohabitat affinity or climatic tolerances (?? niche)? Here we introduce a new test to address this question, based on a modification of the method of independent contrasts. The divergence order test (DOT) is based on the average age of the nodes on a tree, weighted by the absolute magnitude of the contrast at each node for a particular trait. The comparison of these weighted averages reveals whether large divergences for one trait have occurred earlier or later in the course of diversification, relative to a second trait; significance is determined by bootstrapping from maximum-likelihood ancestral state reconstructions. The method is applied to the evolution of Ceanothus, a woody plant group in California, in which co-occurring species exhibit significant differences in a key leaf trait (specific leaf area) associated with contrasting physiological and life history strategies. Co-occurring species differ more for this trait than expected under a null model of community assembly. This ?? niche difference evolved early in the divergence of two major subclades within Ceanothus, whereas climatic distributions (?? niche traits) diversified later within each of the subclades. However, rapid evolution of climate parameters makes inferences of early divergence events highly uncertain, and differentiation of the ?? niche might have taken place throughout the evolution of the group, without leaving a clear phylogenetic signal. Similar patterns observed in several plant and animal groups suggest that early divergence of ?? niche traits might be a common feature of niche evolution in

  16. The relevance of animal experimental results for the assessment of radiation genetic risks in man

    International Nuclear Information System (INIS)

    Stephan, G.

    1981-01-01

    No suitable data are available from man for the quantitative assessment of genetic radiation risk. Therefore, the results from experiments on animals must be utilized. Two hypotheses are presented here in drawing analogical conclusions from one species to another. Although the extrapolation of results from animal experiments remains an open question, the use of experimental results from mice seems to be justified for an assessment of the genetic radiation risk in man. (orig.) [de

  17. Comparison of the result of radiation alone and radiation with daily low dose cisplatin in management of locally advanced cervical cancer

    International Nuclear Information System (INIS)

    Kim, Hun Jung; Kim, Woo Chul; Lee, Mee Jo; Kim, Chul Su; Song, Eun Seop; Loh, John J. K.

    2004-01-01

    An analysis was to compare the results of radiation alone with those of radiation with daily low dose cisplatin as a radiation sensitizer in locally advanced cervical cancer. A retrospective analysis of 59 patients diagnosed with locally advanced uterine cervix cancer between December 1996 and March 2001 was performed. Thirty one patients received radiation alone and 28 patients received daily low dose cisplatin, as a radiation sensitizer, and radiation therapy. The median follow-up period was 34 months, ranging from 2.5 to 73 months. The radiation therapy consisted of 4500 cGy external beam irradiation to the whole pelvis (midline block after 3060 cGy), a 900 ∼ 1,000 cGy boost to the involved parametrium and high dose-rate intracavitary brachytherapy (a total dose of 3,000 ∼ 3,500 cGy/500 cGy per fraction to point A, twice per week). In the chemoradiation group, 10 mg of daily intravenous cisplatin was given daily from the 1st day of radiation therapy to the 20th day of radiation therapy. According to the FIGO classification, the patients were subdivided into 51 (86.4%) and 8 (13.6%) stages IIB and stage IIIB, respectively. The overall 5 year survival rate was 65.65% and according to treatment modality were 56.75% and 73.42% in the radiation alone and chemoradiation groups, respectively (ρ = 0.180). The 5 year disease-free survival rates were 49.39% and 63.34% in the radiation alone and chemoradiation groups, respectively (ρ = 0.053). The 5 year locoregional control rates were 52.34% and 73.58% in the radiation alone and chemoradiation groups, respectively (ρ = 0.013). The 5 year distant disease-free survival rates were 59.29% and 81.46% in the radiation alone and chemoradiation groups, respectively (ρ = 0.477). Treatment related hematologic toxicity were prominent in the chemoradiation group. Leukopenia (≥ 3 grade) occurred in 3.2% and 28.5% of the radiation alone and chemoradiation groups, respectively (ρ = 0.02). There were no statistical differences

  18. Comparison of the result of radiation alone and radiation with daily low dose cisplatin in management of locally advanced cervical cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hun Jung; Kim, Woo Chul; Lee, Mee Jo; Kim, Chul Su; Song, Eun Seop; Loh, John J. K. [Inha University Medical College, Inchon (Korea, Republic of)

    2004-09-15

    An analysis was to compare the results of radiation alone with those of radiation with daily low dose cisplatin as a radiation sensitizer in locally advanced cervical cancer. A retrospective analysis of 59 patients diagnosed with locally advanced uterine cervix cancer between December 1996 and March 2001 was performed. Thirty one patients received radiation alone and 28 patients received daily low dose cisplatin, as a radiation sensitizer, and radiation therapy. The median follow-up period was 34 months, ranging from 2.5 to 73 months. The radiation therapy consisted of 4500 cGy external beam irradiation to the whole pelvis (midline block after 3060 cGy), a 900 {approx} 1,000 cGy boost to the involved parametrium and high dose-rate intracavitary brachytherapy (a total dose of 3,000 {approx} 3,500 cGy/500 cGy per fraction to point A, twice per week). In the chemoradiation group, 10 mg of daily intravenous cisplatin was given daily from the 1st day of radiation therapy to the 20th day of radiation therapy. According to the FIGO classification, the patients were subdivided into 51 (86.4%) and 8 (13.6%) stages IIB and stage IIIB, respectively. The overall 5 year survival rate was 65.65% and according to treatment modality were 56.75% and 73.42% in the radiation alone and chemoradiation groups, respectively ({rho} = 0.180). The 5 year disease-free survival rates were 49.39% and 63.34% in the radiation alone and chemoradiation groups, respectively ({rho} = 0.053). The 5 year locoregional control rates were 52.34% and 73.58% in the radiation alone and chemoradiation groups, respectively ({rho} = 0.013). The 5 year distant disease-free survival rates were 59.29% and 81.46% in the radiation alone and chemoradiation groups, respectively ({rho} = 0.477). Treatment related hematologic toxicity were prominent in the chemoradiation group. Leukopenia ({>=} 3 grade) occurred in 3.2% and 28.5% of the radiation alone and chemoradiation groups, respectively ({rho} = 0.02). There were

  19. Superconducting solenoid model magnet test results

    International Nuclear Information System (INIS)

    Carcagno, R.; Dimarco, J.; Feher, S.; Ginsburg, C.M.; Hess, C.; Kashikhin, V.V.; Orris, D.F.; Pischalnikov, Y.; Sylvester, C.; Tartaglia, M.A.; Terechkine, I.; Tompkins, J.C.; Wokas, T.; Fermilab

    2006-01-01

    Superconducting solenoid magnets suitable for the room temperature front end of the Fermilab High Intensity Neutrino Source (formerly known as Proton Driver), an 8 GeV superconducting H- linac, have been designed and fabricated at Fermilab, and tested in the Fermilab Magnet Test Facility. We report here results of studies on the first model magnets in this program, including the mechanical properties during fabrication and testing in liquid helium at 4.2 K, quench performance, and magnetic field measurements. We also describe new test facility systems and instrumentation that have been developed to accomplish these tests

  20. Superconducting solenoid model magnet test results

    Energy Technology Data Exchange (ETDEWEB)

    Carcagno, R.; Dimarco, J.; Feher, S.; Ginsburg, C.M.; Hess, C.; Kashikhin, V.V.; Orris, D.F.; Pischalnikov, Y.; Sylvester, C.; Tartaglia, M.A.; Terechkine, I.; /Fermilab

    2006-08-01

    Superconducting solenoid magnets suitable for the room temperature front end of the Fermilab High Intensity Neutrino Source (formerly known as Proton Driver), an 8 GeV superconducting H- linac, have been designed and fabricated at Fermilab, and tested in the Fermilab Magnet Test Facility. We report here results of studies on the first model magnets in this program, including the mechanical properties during fabrication and testing in liquid helium at 4.2 K, quench performance, and magnetic field measurements. We also describe new test facility systems and instrumentation that have been developed to accomplish these tests.

  1. HMI Department of Radiation Chemistry: Results of scientific activities in 1984

    International Nuclear Information System (INIS)

    1985-01-01

    In the radiation chemistry department of the Hahn-Meitner-Institute in Berlin, 4 subjects are treated largely the progress of which made in 1984 is herein reported: 1) Interface processes and energy conversion (reaction pathways of photoinduced charge carriers and their in energy conversion mechanisms); 2) Pulse radiolysis (generation and investigation of shortlived chemically quick-reacting particles); 3) Kinematics (reciprocal action with ion, atom and molecule collisions; clarification of the dynamics of chemical reactions; 4) Insulators and plastics/physical and chemical primary processes when these materials are subjected to high-energy radiation, light or UV light). A list of publications and lectures is added to complement the description of results gained from R and D work. (BR) [de

  2. The characteristics of Fugi IP Cassette Type PII and application for radiation oncology quality assurance tests and portal imaging

    International Nuclear Information System (INIS)

    Soh, H.S.; Ung, N.M.; Ng, K.H.

    2008-01-01

    Full text: The advancement of digital imaging has prompted more medical institutions to go filmless. The computed radiography (CR) system is becoming an important tool not only in diagnostic imaging, but also in radiation oncology. A new CR system that was specially designed for the use in radiation oncology. Fuji IP cassette type PII has been introduced to the market in the middle of year 2006. This project aimed to study some basic physical characteristics of this new type of cassette and explore its application for performing quality assurance (QA) tests and portal imaging in radiotherapy. All the images were read by FCR 5000 Plus reader. The image was found to reach its saturation value of 1023 (due to the image was stored in 10 bits data) by depending on the sensitivity value being adjusted. The uniformity test gave the result of 0.12%. The cassette was used to perform the QA tests which were previously performed using film. All the results met the specification as stated in AAPM Task Group 40. The comparison for the portal images of Portal Vision contrast-detail phantom showed that the spatial resolution of the images obtained by CR system (Fujifilm Co.. Ltd.. Tokyo. Japan) were better than the EPID (Varian Medical Systems. Inc.. Palo Alto. USA) and film system (Eastman Kodak Co.. New York. USA). The IP cassette type PII was found to be suitable as an alternative QA test tool and portal imaging in radiotherapy.

  3. The HAW Project. Test disposal of highly radioactive radiation sources in the Asse salt mine

    International Nuclear Information System (INIS)

    Rothfuchs, T.; Mueller-Lyda, I.; Raynal, M.; Major, J.C.

    1993-01-01

    In order to prove the safe disposal of high-level radioactive waste (HAW) in salt a five years test disposal of thirty highly radioactive canisters is planned in the Asse salt mine in the Federal Republic of Germany. The thirty canisters containing the radionuclides Caesium 137 and Strontium 90 in quantities sufficient to cover the bandwith of heat generation and gamma radiation of real HAW will be emplaced in six boreholes located in two galleries at the 800-m-level. Two electrical heater tests were already started in November 1988 and are continuously surveyed in respect of the thermomechanical and geochemical response of the rock mass. Also the handling system necessary for the emplacement of the radioactive canisters was developed and successfully tested. A laboratory investigation programme on radiation effects in salt is being performed in advance to the radioactive canister emplacement. This programme includes the investigation of thermally and radiolytically induced water and gas release from the rock salt and the radiolytical decomposition of salt minerals. For gamma dose and dose rate measurements in the test field measuring systems consisting of ionization chambers as well as solid state dosemeters were developed and tested. 70 refs

  4. Tests of the validity of a model relating frequency of contaminated items and increasing radiation dose

    International Nuclear Information System (INIS)

    Tallentire, A.; Khan, A.A.

    1975-01-01

    The 60 Co radiation response of Bacillus pumilus E601 spores has been characterized when present in a laboratory test system. The suitability of test vessels to act as both containers for irradiation and culture vessels in sterility testing has been checked. Tests have been done with these spores to verify assumptions basic to the general model described in a previous paper. First measurements indicate that the model holds with this laboratory test system. (author)

  5. Large bowel cancer: Indications for and results of radiation as primary or adjuvant treatment

    International Nuclear Information System (INIS)

    Gunderson, L.L.; Rich, T.A.

    1987-01-01

    The intent of this chapter is to develop a logical approach to the use of radiation with large bowel cancer. Incidence and areas of failure after operation alone are outlined by site and stage with implications for adjuvant therapy. Results of series utilizing radiation are presented, and the potential for the future is discussed

  6. The effects of radiation on various materials and the qualification tests required for their use in medical devices

    International Nuclear Information System (INIS)

    Landfield, H.

    1980-01-01

    Many polymers used in the medical field show various degrees of degradation after radiation exposure either by visual or physical measurements. The general effects of radiation on such medical polymers are reviewed and discussed as well as the tests used to qualify their performance. (author)

  7. SU-E-T-19: A New End-To-End Test Method for ExacTrac for Radiation and Plan Isocenter Congruence

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S; Nguyen, N; Liu, F; Huang, Y [Rhode Island Hospital / Warren Alpert Medical, Providence, RI (United States); Sio, T [Mayo Clinic, Rochester, MN (United States); Jung, J [East Carolina University, Greenville, North Carolina (United States); Pyakuryal, A [UniversityIllinois at Chicago, Chicago, IL (United States); Jang, S [Princeton Radiation Oncology Ctr., Jamesburg, NJ (United States)

    2014-06-01

    Purpose: To combine and integrate quality assurance (QA) of target localization and radiation isocenter End to End (E2E) test of BrainLAB ExacTrac system, a new QA approach was devised using anthropomorphic head and neck phantom. This test insures the target localization as well as radiation isocenter congruence which is one step ahead the current ExacTrac QA procedures. Methods: The head and neck phantom typically used for CyberKnife E2E test was irradiated to the sphere target that was visible in CT-sim images. The CT-sim was performed using 1 mm thickness slice with helical scanning technique. The size of the sphere was 3-cm diameter and contoured as a target volume using iPlan V.4.5.2. A conformal arc plan was generated using MLC-based with 7 fields, and five of them were include couch rotations. The prescription dose was 5 Gy and 95% coverage to the target volume. For the irradiation, two Gafchromic films were perpendicularly inserted into the cube that hold sphere inside. The linac used for the irradiation was TrueBeam STx equipped with HD120 MLC. In order to use ExacTrac, infra-red head–array was used to correlate orthogonal X-ray images. Results: Using orthogonal X-rays of ExacTrac the phantom was positioned. For each field, phantom was check again with X-rays and re-positioned if necessary. After each setup using ExacTrac, the target was irradiated. The films were analyzed to determine the deviation of the radiation isocenter in all three dimensions: superior-inferior, left-right and anterior-posterior. The total combining error was found to be 0.76 mm ± 0.05 mm which was within sub-millimeter accuracy. Conclusion: Until now, E2E test for ExacTrac was separately implemented to test image localization and radiation isocenter. This new method can be used for periodic QA procedures.

  8. Outline of the results of test and research at expense of entrusting research on atomic energy peaceful utilization, 1980

    International Nuclear Information System (INIS)

    1982-03-01

    The test research on the substances promoting the recovery from radiation injuries, the research on the security of the facilities using radioisotopes in earthquakes, the test research on the distribution and behavior of radioactive nuclides in environment for the evaluation of exposure dose, the test research on the rate of scattering of RIs, the measurement and dose evaluation of gaseous radioactive nuclides, the research on the measuring techniques for medium and high concentration gaseous tritium, the test research on the evaluation of the effect of low dose radiation on living things, the epidemiological research on low dose effect, the research on the genetic safety of irradiated foods, the test research on the development of radiation sensitizers to cancer cells, the research on the automation and acceleration of the production of short life RI-labeled compounds, the test research on the safety of high performance air filters for nuclear fuel facilities, the test research on the evaluation of the impact properties of nuclear fuel-transporting casks loaded on vehicles, the research on the application of improved security measures to large scale reprocessing facilities, and the test research on the protection capability of countercollision structures for nuclear ships are outlined. (Kako, I.)

  9. Calculating the diffuse solar radiation in regions without solar radiation measurements

    International Nuclear Information System (INIS)

    Li, Huashan; Bu, Xianbiao; Long, Zhen; Zhao, Liang; Ma, Weibin

    2012-01-01

    Correlations for calculating diffuse solar radiation can be classified into models with global solar radiation (H-based method) and without it (Non-H method). The objective of the present study is to compare the performance of H-based and Non-H methods for calculating the diffuse solar radiation in regions without solar radiation measurements. The comparison is carried out at eight meteorological stations in China focusing on the monthly average daily diffuse solar radiation. Based on statistical error tests, the results show that the Non-H method that includes other readily available meteorological elements gives better estimates. Therefore, it can be concluded that the Non-H method is more appropriate than the H-based one for calculating the diffuse solar radiation in regions without solar radiation measurements. -- Highlights: ► Methods for calculating diffuse solar radiation in regions without solar radiation measurements are investigated. ► Diffuse solar radiation models can be classified into two groups according to global solar radiation. ► Two approaches are compared at the eight meteorological stations in China. ► The method without global solar radiation is recommended.

  10. Updated assessment of the six-minute walk test as predictor of acute radiation-induced pneumonitis

    International Nuclear Information System (INIS)

    Mao Jingfang; Zhang Junan; Zhou Sumin; Das, Shiva; Hollis, Donna R.; Folz, Rodney J.; Wong, Terence Z.; Marks, Lawrence B.

    2007-01-01

    Purpose: To assess the utility of the 6-minute walk test (6MWT) as a predictor of symptomatic radiation-induced pneumonitis (RP). Methods: As part of a prospective trial to study radiation-induced lung injury, 53 patients receiving thoracic radiotherapy (RT) underwent a pre-RT 6MWT, pulmonary function tests (PFTs), and had ≥3-month follow-up for prospective assessment of Grade 2 or worse RP (requiring medications or worse). Dosimetric parameters (e.g., the percentage of lung receiving ≥30 Gy) were extracted from the lung dose-volume histogram. The correlations between the 6MWT and PFT results were assessed using Pearson's correlation. The receiver operating characteristic technique was used in patient subgroups to evaluate the predictive capacities for RP of the dosimetric parameters, 6MWT results, and PFT results, or the combination (using discriminant analysis) of all three metrics. ROCKIT software was used to compare the receiver operating characteristic areas between each predictive model. The association of the decline in 6MWT with the development of RP was evaluated using Fisher's exact test. Results: The pre-RT PFT and 6MWT results correlated weakly (r = 0.44-0.57, p ≤ 0.001), suggesting that they measure somewhat different physiologic functions. Of the 53 patients, 9 (17%) developed RP. The dose-volume histogram-based dosimetric parameters were the best single-metric model for predicting RP (e.g., percentage of lung receiving ≥30 Gy, receiver operating characteristic area 0.73, p = 0.03). Including the PFT or 6MWT results with the percentage of lung receiving ≥30 Gy did not improve the predictions. The predictive abilities of dosimetric-based models improved when the analysis was restricted to those patients whose tumors were not causing regional lung dysfunction. No correlation was found between the decline in the 6MWT result and the RP rate (p = 0.6). Conclusion: Although the PFTs and 6MWT are related to each other, the correlation coefficients

  11. Estimation of the committed radiation dose resulting from gamma radionuclides ingested with food

    International Nuclear Information System (INIS)

    Piotr Godyn; Agnieszka Dolhanczuk-Srodka; Zbigniew Ziembik; Ewa Moliszewska

    2014-01-01

    The objective of the study was to estimate the value of the radiation dose absorbed in consequence of consumption of popular food products for individual age groups. Potatoes, corn and sugar beet were selected for the study. Edible parts of these plants were collected in experimental fields of the KWS Lochow Polska Sp. z o.o. seeding company in Kondratowice (Poland). On the basis of the obtained study results, it can be stated that in consequence of consumption of the selected food products, people may receive increased doses from both natural and artificial radioactive isotopes. The doses calculated for several age groups do not show any health hazards in consequence of consumption of the tested food. One of the determined radionuclides was 137 Cs; however, its presence in the absorbed dose is lower than the doses from natural radioactive isotopes, in particular 40 K. (author)

  12. A summary of EPA radon chamber tests and results for rounds 3 and 4 of the National Radon Measurement Proficiency Program

    International Nuclear Information System (INIS)

    Smith, J.M.; Sensintaffar, E.L.

    1993-02-01

    The US Environmental Protection Agency's Office of Radiation and Indoor Air (ORIA) established the National Radon Measurement Proficiency (RMP) Program in 1986. Through this voluntary program, participants can demonstrate their ability to measure radon and/or radon decay products by submitting their detection devices to a blind test in a designated radon chamber. In this report, two EPA radon and radon decay products test chambers (chambers A and C) located at the National Air and Radiation Environmental Laboratory in Montgomery, Alabama are described. These chambers were used to expose detectors submitted for testing in Round 4 of the National Radon Measurement Proficiency Program and are used routinely for calibration purposes. Also described are the measurement and calibration procedures which were used to establish the official target values for radon and radon decay products concentrations during RMP Round 4 testing. The results for RMP Round 3 (conducted at the US DOE Environmental Measurements Laboratory radon chamber in New York) and RMP Round 4 (conducted in the two NAREL chambers) are discussed and compared. Following Round 4, the NAREL staff analyzed the collective performance for each measurement method tested in these rounds and found that all methods agreed with the target values within expected limits except for RPISU's and charcoal adsorbers. After analyzing the RMP4 results, NAREL staff spent several months evaluating the difference in charcoal adsorber response between Round 3 and 4 by performing radon chamber tests using EPA 4-inch, open-faced charcoal adsorbers

  13. Radiation damage calculations for the APT materials test program

    International Nuclear Information System (INIS)

    Corzine, R.K.; Wechsler, M.S.; Dudziak, D.J.; Ferguson, P.D.; James, M.R.

    1999-01-01

    A materials irradiation was performed at the Los Alamos Neutron Science Center (LANSCE) in the fall of 1996 and spring of 1997 in support of the Accelerator Production of Tritium (APT) program. Testing of the irradiated materials is underway. In the proposed APT design, materials in the target and blanket are to be exposed to protons and neutrons over a wide range of energies. The irradiation and testing program was undertaken to enlarge the very limited direct knowledge presently available of the effects of medium-energy protons (∼1 GeV) on the properties of engineering materials. APT candidate materials were placed in or near the LANSCE accelerator 800-MeV, 1-mA proton beam and received roughly the same proton current density in the center of the beam as would be the case for the APT facility. As a result, the proton fluences achieved in the irradiation were expected to approach the APT prototypic full-power-year values. To predict accurately the performance of materials in APT, radiation damage parameters for the materials experiment must be determined. By modeling the experiment, calculations for atomic displacement, helium and hydrogen cross sections and for proton and neutron fluences were done for representative samples in the 17A, 18A, and 18C areas. The LAHET code system (LCS) was used to model the irradiation program, LAHET 2.82 within LCS transports protons > 1 MeV, and neutrons >20 MeV. A modified version of MCNP for use in LCS, HMCNP 4A, was employed to tally neutrons of energies <20 MeV

  14. Space radiation environment

    International Nuclear Information System (INIS)

    Garrett, H.B.

    1998-01-01

    Coupled with the increasing concern over trapped radiation effects on microelectronics, the availability of new data, long term changes in the Earth's magnetic field, and observed variations in the trapped radiation fluxes have generated the need for better, more comprehensive tools for modeling and predicting the Earth's trapped radiation environment and its effects on space systems. The objective of this report is to describe the current status of those efforts and review methods for attacking the issues associated with modeling the trapped radiation environment in a systematic, practical fashion. The ultimate goal will be to point the way to increasingly better methods of testing, designing, and flying reliable microelectronic systems in the Earth's radiation environment. The review will include a description of the principal models of the trapped radiation environment currently available--the AE8 and AP8 models. Recent results rom radiation experiments on spacecraft such as CRRES, SAMPEX, and CLEMENTINE will then be described. (author)

  15. Radiation protection clothes in X-ray-diagnostics. Comparison of test methods

    International Nuclear Information System (INIS)

    Pichler, T.; Schoepf, T.; Ennemoser, O.

    2009-01-01

    For testing the attenuation of the protection clothes the standard EN 61331-1 for attenuation measurements in the ''narrow and broad beam'' is available as well as the DIN 6857-1 for determination of shielding properties in the so called ''inverse broad-beam geometry''. The attenuation measurements in the narrow beam don't consider scattered radiation and fluorescence due to the arrangement. This leads to the fact that the protective effect of lead-free-Materials will be miss-estimated when compared to lead. In this work the measurements of shielding properties in inverse broad-beam geometry according to the DIN 6857-1 were compared with attenuation measurements according to the EN 61331-1. Also the dependence of the chamber was studied. Attenuation measurements were performed with lead- and lead-free-materials. Additional certificated lead-foils with high purity and precise thickness of 0.1 to 2 mm were used. For measuring a cylinder chamber of 30 cm 3 and two flat chambers of 75 cm 3 (SFD) and 112 cm 3 (FC) were used. The measurements in inverse broad-beam geometry according to the DIN 6857-1 show adequate results, also in testing lead-free protection materials. The results in attenuation correspond to a large extent to those, which are determined by measurements in the broad beam. When performing measurements in inverse geometry however the characteristic of the used chamber is not negligible. (orig.)

  16. Legal provisions governing the acknowledgment of test results

    International Nuclear Information System (INIS)

    Strecker, A.

    1982-01-01

    The legal provisions governing the acknowledgment of test results are most frequently applied by administrative orders (design and qualification approvals or specimen testing and approval) and are thus claimable and voidable in accordance with general administrative law. The acknowledgment of test certificates requires a legal basis. Test results, however, can be acknowledged also by administrative bodies. Recently, the Federal Government began to delegate more of its legal authority in this field to private institutions, allowing test results to be acknowledged and test certificates to be issued by government controlled private institutions. (orig.) [de

  17. Recent progress and tests of radiation resistant impregnation materials for Nb3Sn coils

    International Nuclear Information System (INIS)

    Bossert, R.; Krave, S.; Ambrosio, G.; Andreev, N.; Chlachidze, G.; Nobrega, A.; Novitski, I.; Yu, M.; Zlobin, A. V.

    2014-01-01

    Fermilab is collaborating with Lawrence Berkeley National Laboratory (LBNL) and Brookhaven National Laboratory (BNL) (US-LARP collaboration) to develop a large-aperture Nb 3 Sn superconducting quadrupole for the Large Hadron Collider (LHC) luminosity upgrade. An important component of this work is the development of materials that are sufficiently radiation resistant for use in critical areas of the upgrade. This paper describes recent progress in characterization of materials, including the baseline CTD101K epoxy, cyanate ester blends, and Matrimid 5292, a bismaleimide-based system. Structural properties of “ten stacks” of cable impregnated with these materials are tested at room and cryogenic temperatures and compared to the baseline CT-101K. Experience with potting 1 and 2 meter long coils with Matrimid 5292 are described. Test results of a single 1-m coil impregnated with Matrimid 5292 are reported and compared to similar coils impregnated with the traditional epoxy

  18. Recent progress and tests of radiation resistant impregnation materials for Nb3Sn coils

    Science.gov (United States)

    Bossert, R.; Krave, S.; Ambrosio, G.; Andreev, N.; Chlachidze, G.; Nobrega, A.; Novitski, I.; Yu, M.; Zlobin, A. V.

    2014-01-01

    Fermilab is collaborating with Lawrence Berkeley National Laboratory (LBNL) and Brookhaven National Laboratory (BNL) (US-LARP collaboration) to develop a large-aperture Nb3Sn superconducting quadrupole for the Large Hadron Collider (LHC) luminosity upgrade. An important component of this work is the development of materials that are sufficiently radiation resistant for use in critical areas of the upgrade. This paper describes recent progress in characterization of materials, including the baseline CTD101K epoxy, cyanate ester blends, and Matrimid 5292, a bismaleimide-based system. Structural properties of "ten stacks" of cable impregnated with these materials are tested at room and cryogenic temperatures and compared to the baseline CT-101K. Experience with potting 1 and 2 meter long coils with Matrimid 5292 are described. Test results of a single 1-m coil impregnated with Matrimid 5292 are reported and compared to similar coils impregnated with the traditional epoxy.

  19. Electrical pulse burnout of transistors in intense ionizing radiation

    International Nuclear Information System (INIS)

    Hartman, E.F.; Evans, D.C.

    1975-01-01

    Tests examining possible synergistic effects of electrical pulses and ionizing radiation on transistors were performed and energy/power thresholds for transistor burnout determined. The effect of ionizing radiation on burnout thresholds was found to be minimal, indicating that electrical pulse testing in the absence of radiation produces burnout-threshold results which are applicable to IEMP studies. The conditions of ionized transistor junctions and radiation induced current surges at semiconductor device terminals are inherent in IEMP studies of electrical circuits

  20. Radiation dosimetry and radiation biophysics

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    Radiation dosimetry and radiation biophysics are two closely integrated programs whose joint purpose is to explore the connections between the primary physical events produced by radiation and their biological consequences in cellular systems. The radiation dosimetry program includes the theoretical description of primary events and their connection with the observable biological effects. This program also is concerned with the design and measurement of physical parameters used in theory or to support biological experiments. The radiation biophysics program tests and uses the theoretical developments for experimental design, and provides information for further theoretical development through experiments on cellular systems

  1. Radiation dosimetry and radiation biophysics

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    Radiation dosimetry and radiation biophysics are two closely integrated programs whose joint purpose is to explore the connections between the primary physical events produced by radiation and their biological consequences in cellular systems. The radiation dosimetry program includes the theoretical description of primary events and their connection with the observable biological effects. This program also is concerned with design and measurement of those physical parameters used in the theory or to support biological experiments. The radiation biophysics program tests and makes use of the theoretical developments for experimental design. Also, this program provides information for further theoretical development through experiments on cellular systems

  2. Thyroid nodule prevalence and radiation dose from fallout near the Semipalatinsk test site in Kazakhstan

    International Nuclear Information System (INIS)

    Land, C.E.; Luckyanov, N.K.; Simon, S.L.; Zhumadilov, Z.; Gusev, B.I.; Hartshorne, M.N.; Carr, Z.A.

    2003-01-01

    Thyroid nodule prevalence was use as a biomarker for radiation-related thyroid cancer risk associated with dose from internal and external radiation sources in fallout from the Semipalatinsk Test Site (STS) in Kazakhstan. Ultrasound scans were done on the thyroid glands of 1990 current residents of 7 villages near the STS, all members of a defined study cohort established in the 1960s, and all juveniles at some time during 1949-1962. Questionnaire-guided interviews focused on residential history and childhood consumption of milk and milk products. A refined dose reconstruction algorithm, developed jointly by experts from Russia and the US, was applied to the resulting data to calculate individual estimates of thyroid dose from external and internal sources of fallout-related radiation. Individual radiation dose estimates ranged from zero to 20 Gy for total dose (0-1.7 Gy and 0-20 Gy for dose from external and internal sources, respectively). The ratio of internal to external dose generally increased with increasing distance, reflecting a shift towards smaller particle sizes at greater distances and more effective transfer of small particles through the foodchain. Dose-response analysis was focused on variation of nodule prevalence by sex, age at screening, measured thyroid volume, and reconstructed thyroid dose from external (mainly gamma-ray) and internal (mainly 131 I) radiation sources. Nodule prevalence was markedly higher among women and increased significantly with increasing age at screening and with thyroid volume. Highly significant dose responses were observed for nodule prevalence as a function of total thyroid dose and, in a separate analysis, of doses from internal and external sources as distinct independent variables; dose response was linear for total dose 131 I cf. x ray with respect to thyroid cancer as an endpoint, based on theoretical, experimental, and epidemiological data

  3. Multidisciplinary approach to radiation late effects in the brain circulatory system: First results

    International Nuclear Information System (INIS)

    Keyeux, A.J.M.; Reinhold, H.S.; Gerber, G.B.; Maisin, J.R.; Reyners, H.; Gianfelici de Reyners, E.; Calvo, W.

    1976-01-01

    Although acute vascular damage and the early functional impairment of the central nervous system has been studied relatively frequently, the pathophysiological mechanisms of late radiation effects and their relevance to vascular damage, are less well investigated and are poorly understood. As the possibility of later radiation damage is a factor which limits the therapist in the radiation dose, he can give to effect a local tumour cure, it is essential that the mechanisms and importance of vascular irradiation damage be determined before late effects can either be treated or avoided. In view of the inconclusive results obtained by previous authors, it was felt that a multidisciplinary approach might better be suited to solve this problem. Thus, in 1973 a research project was initiated by EULEP to investigate the origins and consequences of radiation induced vascular changes after local irradiation of the brain. In this preliminary report, data on morphological, circulatory and biochemical parameters are presented and discussed. (GC)

  4. Titanium-Water Thermosyphon Gamma Radiation Exposure and Results

    Science.gov (United States)

    Sanzi, James, L.A; Jaworske, Donald, A.; Goodenow, Debra, A.

    2012-01-01

    Titanium-water thermosyphons are being considered for use in heat rejection systems for fission power systems. Their proximity to the nuclear reactor will result in some gamma irradiation. Noncondensable gas formation from radiation-induced breakdown of water over time may render portions of the thermosyphon condenser inoperable. A series of developmental thermosyphons were operated at nominal operating temperature under accelerated gamma irradiation, with exposures on the same order of magnitude as that expected in 8 years of heat rejection system operation. Temperature data were obtained during exposure at three locations on each thermosyphon: evaporator, condenser, and condenser end cap. Some noncondensable gas was evident; however, thermosyphon performance was not affected because the noncondensable gas was compressed into the fill tube region at the top of the thermosyphon, away from the heat rejecting fin. The trend appeared to be an increasing amount of noncondensable gas formation with increasing gamma irradiation dose. Hydrogen is thought to be the most likely candidate for the noncondensable gas and hydrogen is known to diffuse through grain boundaries. Post-exposure evaluation of one thermosyphon in a vacuum chamber and at temperature revealed that the noncondensable gas diffused out of the thermosyphon over a relatively short period of time. Further research shows a number of experimental and theoretical examples of radiolysis occurring through gamma radiation alone in pure water.

  5. Titanium-Water Thermosyphon Gamma Radiation Effects and Results

    Science.gov (United States)

    Sanzi, James L.; Jaworske, Donald A.; Goodenow, Debra A.

    2012-01-01

    Titanium-water thermosyphons are being considered for use in heat rejection systems for fission power systems. Their proximity to the nuclear reactor will result in some exposure to gamma irradiation. Non-condensable gas formation from radiation may breakdown water over time and render a portion of the thermosyphon condenser inoperable. A series of developmental thermosyphons were operated at nominal operating temperature with accelerated gamma irradiation exposures on the same order of magnitude that is expected in eight years of heat rejection system operation. Temperature data were obtained during exposure at three locations on each thermosyphon; evaporator, condenser, and condenser end cap. Some non-condensable gas was evident, however thermosyphon performance was not affected because the non-condensable gas was compressed into the fill tube region at the top of the thermosyphon, away from the heat rejecting fin. The trend appeared to be an increasing amount of non-condensable gas formation with increasing gamma irradiation dose. Hydrogen is thought to be the most likely candidate for the non-condensable gas and hydrogen is known to diffuse through grain boundaries. Post-exposure evaluation of selected thermosyphons at temperature and in a vacuum chamber revealed that the non-condensable gas likely diffused out of the thermosyphons over a relatively short period of time. Further research shows a number of experimental and theoretical examples of radiolysis occurring through gamma radiation alone in pure water.

  6. Effects in Plant Populations Resulting from Chronic Radiation Exposure

    Energy Technology Data Exchange (ETDEWEB)

    Geras' kin, Stanislav A.; Volkova, Polina Yu.; Vasiliyev, Denis V.; Dikareva, Nina S.; Oudalova, Alla A. [Russian Institute of Agricultural Radiology and Agroecology, 249032, Obninsk (Russian Federation)

    2014-07-01

    Human industrial activities have left behind a legacy of ecosystems strongly impacted by a wide range of contaminants, including radionuclides. Phyto-toxic effects of acute impact are well known, but the consequences of long-term chronic exposure to low pollutant concentrations is neither well understood nor adequately included in risk assessments. To understand effects of real-world contaminant exposure properly we must pay attention to what is actually going on in the field. However, for many wildlife groups and endpoints, there are no, or very few, studies that link accumulation, chronic exposure and biological effects in natural settings. To fill the gaps, results of field studies carried out on different plant species (winter rye and wheat, spring barley, oats, Scots pine, wild vetch, crested hair-grass) in various radioecological situations (nuclear weapon testing, the Chernobyl accident, uranium and radium processing) to investigate effects of long-term chronic exposure to radionuclides are discussed. Because each impacted site developed in its own way due to a unique history of events, the experience from one case study is rarely directly applicable to another situation. In spite of high heterogeneity in response, we have detected several general patterns. Plant populations growing in areas with relatively low levels of pollution are characterized by the increased level of both cytogenetic alterations and genetic diversity. Accumulation of cellular alterations may afterward influence biological parameters important for populations such as health and reproduction. Presented data provide evidence that in plant populations inhabiting heavily contaminated territories cytogenetic damage were accompanied by decrease in reproductive ability. In less contaminated sites, because of the scarcity of data available, it is impossible to establish exactly the relationship between cytogenetic effects and reproductive ability. Radioactive contamination of the plants

  7. Actual questions of radiographic testing and radiation protection. Contributions; Aktuelle Fragen der Durchstrahlungspruefung und des Strahlenschutzes. Beitraege

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2017-08-01

    The proceedings of the 17th DGZfP seminar include nine contributions on the use of radiography for periodic non destructive testing purposes and issues of radiation protection for the testing personnel and the security of radioactive materials.

  8. Real-time and on-site γ-ray radiation response testing system for semiconductor devices and its applications

    Energy Technology Data Exchange (ETDEWEB)

    Mu, Yifei, E-mail: Y.Mu@student.liverpool.ac.uk [Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool L69 3GJ (United Kingdom); Zhao, Ce Zhou, E-mail: cezhou.zhao@xjtlu.edu.cn [Department of Electrical and Electronic Engineering, Xi’an Jiaotong-Liverpool University, Suzhou 215123 (China); Qi, Yanfei, E-mail: yanfei.qi01@xjtlu.edu.cn [Department of Electrical and Electronic Engineering, Xi’an Jiaotong-Liverpool University, Suzhou 215123 (China); Lam, Sang, E-mail: s.lam@xjtlu.edu.cn [Department of Electrical and Electronic Engineering, Xi’an Jiaotong-Liverpool University, Suzhou 215123 (China); Zhao, Chun, E-mail: garyzhao@ust.hk [Nano and Advanced Materials Institute, Hong Kong University of Science and Technology, Kowloon (Hong Kong); Lu, Qifeng, E-mail: qifeng@liverpool.ac.uk [Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool L69 3GJ (United Kingdom); Cai, Yutao, E-mail: yutao.cai@xjtlu.edu.cn [Department of Electrical and Electronic Engineering, Xi’an Jiaotong-Liverpool University, Suzhou 215123 (China); Mitrovic, Ivona Z., E-mail: ivona@liverpool.ac.uk [Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool L69 3GJ (United Kingdom); Taylor, Stephen, E-mail: s.taylor@liverpool.ac.uk [Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool L69 3GJ (United Kingdom); Chalker, Paul R., E-mail: pchalker@liverpool.ac.uk [Center for Materials and Structures, School of Engineering, University of Liverpool, Liverpool L69 3GH (United Kingdom)

    2016-04-01

    The construction of a turnkey real-time and on-site radiation response testing system for semiconductor devices is reported. Components of an on-site radiation response probe station, which contains a 1.11 GBq Cs{sup 137} gamma (γ)-ray source, and equipment of a real-time measurement system are described in detail for the construction of the whole system. The real-time measurement system includes a conventional capacitance–voltage (C–V) and stress module, a pulse C–V and stress module, a conventional current–voltage (I–V) and stress module, a pulse I–V and stress module, a DC on-the-fly (OTF) module and a pulse OTF module. Electrical characteristics of MOS capacitors or MOSFET devices are measured by each module integrated in the probe station under continuous γ-ray exposure and the measurement results are presented. The dose rates of different gate dielectrics are calculated by a novel calculation model based on the Cs{sup 137} γ-ray source placed in the probe station. For the sake of operators’ safety, an equivalent dose rate of 70 nSv/h at a given operation distance is indicated by a dose attenuation model in the experimental environment. HfO{sub 2} thin films formed by atomic layer deposition are employed to investigate the radiation response of the high-κ material by using the conventional C–V and pulse C–V modules. The irradiation exposure of the sample is carried out with a dose rate of 0.175 rad/s and ±1 V bias in the radiation response testing system. Analysis of flat-band voltage shifts (ΔV{sub FB}) of the MOS capacitors suggests that the on-site and real-time/pulse measurements detect more serious degradation of the HfO{sub 2} thin films compared with the off-site irradiation and conventional measurement techniques.

  9. Characterization and radiation studies of diode test structures in LFoundry CMOS technology

    Energy Technology Data Exchange (ETDEWEB)

    Daas, Michael; Gonella, Laura; Hemperek, Tomasz; Huegging, Fabian; Krueger, Hans; Pohl, David-Leon; Wermes, Norbert [Physikalisches Institut der Universitaet Bonn (Germany); Macchiolo, Anna [Max-Planck-Institut fuer Physik, Muenchen (Germany)

    2016-07-01

    In order to prepare for the High Luminosity upgrade of the LHC, all subdetector systems of the ATLAS experiment will be upgraded. In preparation for this process, different possibilities for new radiation-hard and cost-efficient silicon sensor technologies to be used as part of hybrid pixel detectors in the ATLAS inner tracker are being investigated. One promising way to optimize the cost-efficiency of silicon-based pixel detectors is to use commercially available CMOS technologies such as the 150 nm process by LFoundry. In this talk, several CMOS pixel test structures, such as simple diodes and small pixel arrays, that were manufactured in this technology are characterized regarding general performance and radiation hardness and compared to each other as well as to the current ATLAS pixel detector.

  10. Fabrication of vitrified isotopic heat and radiation sources for testing in the Asse Mine

    International Nuclear Information System (INIS)

    Holton, L.K.; Burkholder, H.C.; McElroy, J.L.; Kahl, L.; Kroebel, R.; Rothfuchs, T.; Strippler, R.

    1989-02-01

    The Pacific Northwest Laboratory (PNL), under contract to the US Department of Energy, has produced 30 isotopic heat and radiation sources (canisters) for the Federal Republic of Germany (FRG) to be used as part of a repository testing program in the Asse Salt Mine. PNL was responsible for the fabrication, including filling, closing, decontaminating, and characterizing the canisters. The canisters were fabricated (filled) in three separate processing campaigns using the radioactive liquid-fed ceramic melter to produce a borosilicate glass. Radiochemical constituents ( 137 Cs and 90 Sr) were immobilized within the borosilicate glass matrix to yield a product with a predetermined decay heat and surface radiation exposure rate. Canister lid-welding was completed using an autogenous gas tungsten arc welding process. A helium leak test of lid weld tightness verified the leak rate to be no greater than 2.4 /times/ 10/sup /minus/8/ atm-cc/sec, which was less than the criterion of 10/sup /minus/7/ atm-cc/sec. The top, sides, and bottom of the canisters were decontaminated by electropolishing. All canisters were decontaminated to surface smear contamination levels of less than 33 Bq/100 cm 2 beta-gamma radiation. No significant alpha contamination was observed on canister surfaces. 11 figs., 2 tabs

  11. Radiation pneumonitis: a complication resulting from combined radiation and chemotherapy for early breast cancer

    International Nuclear Information System (INIS)

    Gez, E.; Sulkes, A.; Isacson, R.; Catane, R.; Weshler, Z.

    1985-01-01

    Described is a patient with early breast carcinoma who developed clinical radiation pneumonitis during primary radiation therapy and concomitant chemotherapy that included prednisone. This syndrome developed three days following abrupt steroid withdrawal. Retrieval of steroids brought complete resolution of the clinical and radiological findings. Although this syndrome is rare, it is recommended that steroid therapy in a patient previously irradiated to the chest be avoided

  12. Foam radiators for transition radiation detectors

    International Nuclear Information System (INIS)

    Chernyatin, V.; Dolgoshein, B.; Gavrilenko, I.; Potekhin, M.; Romaniouk, A.; Sosnovtsev, V.

    1993-01-01

    A wide variety of foam radiators, potentially useful in the design of a transition radiation detector, the possible particle identification tool in collider experiments, have been tested in the beam. Various characteristics of these radiators are compared, and the conclusion is reached that certain brands of polyethylene foam are best suited for use in the detector. Comparison is made with a 'traditional' radiator, which is a periodic structure of plastic foils. (orig.)

  13. Gamma radiation grafted polymers for immobilization of Brucella antigen in diagnostic test studies

    Science.gov (United States)

    Docters, E. H.; Smolko, E. E.; Suarez, C. E.

    The radiation grafting process has a wide field of industrial applications, and in the recent years the immobilization of biocomponents in grafted polymeric materials obtained by means of ionizing radiations is a new and important contribution to biotechnology. In the present work, gamma preirradiation grafting method was employed to produce acrylics hydrogels onto polyethylene (PE), polyvinyl chloride (PVC) and polystyrene (PS). Two monomers were used to graft the previously mentioned polymers: methacrylic acid (MAAc) and acrylamide (AAm), and several working conditions were considered as influencing the degree of grafting. All this grafted polymers were used to study the possibility of a subsequent immobilization of Brucella antigen (BAg) in diagnostic test studies (ELISA).

  14. Gamma radiation grafted polymers for immobilization of Brucella antigen in diagnostic test studies

    International Nuclear Information System (INIS)

    Docters, E.H.; Smolko, E.E.

    1990-01-01

    The radiation grafting process has a wide field of industrial applications, and in the recent years the immobilization of biocomponents in grafted polymeric materials obtained by means of ionizing radiations is a new and important contribution to biotechnology. In the present work, gamma preirradiation grafting method was employed to produce acrylics hydrogels onto polyethylene (PE), polyvinyl chloride (PVC) and polystyrene (PS). Two monomers were used to graft the previously mentioned polymers: methacrylic acid (MAAc) and acrylamide (AAm), and several working conditions were considered as influencing the degree of grafting. All these grafted polymers were used to study the possibility of a subsequent immobilization of Brucella antigen (BAg) in diagnostic test studies (ELISA). (author)

  15. Gamma radiation grafted polymers for immobilization of Brucella antigen in diagnostic test studies

    Energy Technology Data Exchange (ETDEWEB)

    Docters, E H; Smolko, E E [Comision Nacional de Energia Atomica, Buenos Aires (Argentina). Direccion de Radioisotopos y Radiaciones; Suarez, C E [Instituto Nacional de Tecnologia Agropecuaria, Castelar (Argentina)

    1990-01-01

    The radiation grafting process has a wide field of industrial applications, and in the recent years the immobilization of biocomponents in grafted polymeric materials obtained by means of ionizing radiations is a new and important contribution to biotechnology. In the present work, gamma preirradiation grafting method was employed to produce acrylics hydrogels onto polyethylene (PE), polyvinyl chloride (PVC) and polystyrene (PS). Two monomers were used to graft the previously mentioned polymers: methacrylic acid (MAAc) and acrylamide (AAm), and several working conditions were considered as influencing the degree of grafting. All these grafted polymers were used to study the possibility of a subsequent immobilization of Brucella antigen (BAg) in diagnostic test studies (ELISA). (author).

  16. Main results and tasks in studies on radiation safety ensurance when using nuclear power and radiation sources in national economy

    International Nuclear Information System (INIS)

    Semenov, A.P.; Ivanov, V.I.

    1978-01-01

    The basic problems and the results of work in the field of ensuring radiation safety for personnel engaged in work related to the use of nuclear energy and sources of ionizing radiation are discussed. Long standing observation of labour hygiene and health conditions of people engaged at research nuclear reactors have shown that the irradiation levels under normal operating conditions do not exceed the established standards. Radiation conditions in radiological laboratories have been studied. Much attention is given to studies of internal irradiation due to inhalation of radioactive aerosols. New methods and apparatuses have been developed for analysis of aerosols and control of intake of radioactive substances by man. Work has been done to improve the methods of emergency dosimetry and design of individual emergency dosimeters. Investigations have been performed to determine the safety levels in working with rare-metal ores containing naturally occurring radioactive substances and industrial radiochemical processes. It is of interest to study small load doses. Different documents for providing safety in working with sources of ionizing radiation have been developed

  17. Relationship between ultrasonic pulse velocity test result and ...

    African Journals Online (AJOL)

    Ultrasonic Pulse Velocity test result showed an inverse relationship (of -0.935) with the crushed concrete compressive strength. Correlation test, multiple regression analysis, graphs and visual inspection were used to analyze the results. The conclusion drawn is that there exists a relationship between UPV test results and ...

  18. Synthesis of functional materials by radiation and qualification testing of organic materials in nuclear power plant

    International Nuclear Information System (INIS)

    Nho, Young Chang; Kim, Ki Yup; Kang, Phil Hyun and others; Jun, Hong Jae; Suh, Dong Hak; Lee, Young Moo; Min, Byung Kak; Bae, You Han

    2003-05-01

    The radiation crosslinking and grafting can be easily adjusted and is easily reproducible by controlling the radiation dose. These studies aim to develop new biomaterials such as covering for burns and wound, and controlled release of drug. A radiation technology was used to develop PTC materials useful in devices that limit electric fault currents. Radiation-curing of fiber-matrix composites is a promising application. There are a number of advantages to radiation curing of composites, compared with conventional thermal processing. Radiation curing at ambient temperature allows tighter control of part dimensions, and elimination of internal stresses which otherwise occur on cooling and which reduce material strength. These studies involved radiation curing of epoxy resins with various fibers and filler for structural application for aerospace and sport goods. The chain scission is the basis of other radiation treatments aimed at enhancing processing characteristics of polymers. These studies aim to make PTFE powder from PTFE scrap using the radiation degradation which allows incorporation of the material into coatings, inks etc. Low density polyethylene, crosslinked polyethylene, ethylene propylene rubber, and acrylonitrile butadiene rubber as cable insulating, seathing and sealing materials were irradiated for the accelerated ageing tests. Degradation was investigated by measuring dielectric analysis, thermogravimetric analysis, and dynamic mechanical analysis. Dielectric tanδ, storage modulus and loss modulus were increased with irradiation doses. However, decomposition temperature decreased with irradiation doses

  19. Radiation Detection Computational Benchmark Scenarios

    Energy Technology Data Exchange (ETDEWEB)

    Shaver, Mark W.; Casella, Andrew M.; Wittman, Richard S.; McDonald, Ben S.

    2013-09-24

    Modeling forms an important component of radiation detection development, allowing for testing of new detector designs, evaluation of existing equipment against a wide variety of potential threat sources, and assessing operation performance of radiation detection systems. This can, however, result in large and complex scenarios which are time consuming to model. A variety of approaches to radiation transport modeling exist with complementary strengths and weaknesses for different problems. This variety of approaches, and the development of promising new tools (such as ORNL’s ADVANTG) which combine benefits of multiple approaches, illustrates the need for a means of evaluating or comparing different techniques for radiation detection problems. This report presents a set of 9 benchmark problems for comparing different types of radiation transport calculations, identifying appropriate tools for classes of problems, and testing and guiding the development of new methods. The benchmarks were drawn primarily from existing or previous calculations with a preference for scenarios which include experimental data, or otherwise have results with a high level of confidence, are non-sensitive, and represent problem sets of interest to NA-22. From a technical perspective, the benchmarks were chosen to span a range of difficulty and to include gamma transport, neutron transport, or both and represent different important physical processes and a range of sensitivity to angular or energy fidelity. Following benchmark identification, existing information about geometry, measurements, and previous calculations were assembled. Monte Carlo results (MCNP decks) were reviewed or created and re-run in order to attain accurate computational times and to verify agreement with experimental data, when present. Benchmark information was then conveyed to ORNL in order to guide testing and development of hybrid calculations. The results of those ADVANTG calculations were then sent to PNNL for

  20. Radiation resistance of optical fibers, (10)

    International Nuclear Information System (INIS)

    Tsunoda, Tsunemi; Ara, Katsuyuki; Morimoto, Naoki; Sanada, Kazuo; Inada, Koichi.

    1991-01-01

    Optical fibers have many excellent characteristics such as the light weight of the material, insulation, the noninductivity of electromagnetic interference noise, the wide band of signal transmission, and small loss. Also in the field of atomic energy, the utilization of optical fibers is positively expanded, and the research on the method of application and so on has been advanced. However in optical fibers, there is the problem that color centers are formed at the relatively low level of radiation, and they are colored. Accordingly, for effectively utilizing optical fibers in radiation environment, it is indispensable to improve their radiation resistance. For the purpose of solving this problem, the authors have carried out the basic research on the effect that radiation exerts to optical fibers and the development of the optical fibers having excellent radiation resistance. For the purpose of expanding the range of application of GeO 2 -doped silica core fibers including GI type in radiation regions, the transmission characteristics of the fibers during irradiation were examined by using the Cl content as the parameter. Therefore, the results are reported. The fibers put to the test, the testing method and the results are described. (K.I.)

  1. External radiation in Dolon village due to local fallout from the first USSR atomic bomb test in 1949.

    Science.gov (United States)

    Imanaka, Tetsuji; Fukutani, Satoshi; Yamamoto, Masayoshi; Sakaguchi, Aya; Hoshi, Masaharu

    2006-02-01

    Dolon village, located about 60 km from the border of the Semipalatinsk Nuclear Test Site, is known to be heavily contaminated by local fallout from the first USSR atomic bomb test in 1949. External radiation in Dolon was evaluated based on recent 137Cs data in soil and calculation of temporal change in the fission product composition. After fitting a log-normal distribution to the soil data, a 137Cs deposition of 32 kBq m-2, which corresponds to the 90th-percentile of the distribution, was tentatively chosen as a value to evaluate the radiation situation in 1949. Our calculation indicated that more than 95% of the cumulative dose for 50 y had been delivered within 1 y after the deposition. The resulting cumulative dose for 1 y after the deposition, normalized to the initial contamination containing 1 kBq m-2 of 137Cs, was 15.6 mGy, assuming a fallout arrival time of 3 h and a medium level of fractionation. Finally, 0.50 Gy of absorbed dose in air was derived as our tentative estimate for 1-year cumulative external dose in Dolon due to local fallout from the first USSR test in 1949.

  2. Testing of Sapphire Optical Fiber and Sensors in Intense Radiation Fields When Subjected to Very High Temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Blue, Thomas [The Ohio State Univ., Columbus, OH (United States); Windl, Wolfgang [The Ohio State Univ., Columbus, OH (United States)

    2017-12-15

    The primary objective of this project was to determine the optical attenuation and signal degradation of sapphire optical fibers & sensors (temperature & strain), in-situ, operating at temperatures up to 1500°C during reactor irradiation through experiments and modeling. The results will determine the feasibility of extending sapphire optical fiber-based instrumentation to extremely high temperature radiation environments. This research will pave the way for future testing of sapphire optical fibers and fiber-based sensors under conditions expected in advanced high temperature reactors.

  3. Sucralfate for radiation mucositis: results of a double-blind randomized trial

    International Nuclear Information System (INIS)

    Meredith, R.; Salter, M.; Kim, R.; Spencer, S.; Weppelmann, B.; Rodu, B.; Smith, J.; Lee, J.

    1995-01-01

    Purpose: To determine if addition of the ulcer-coating polysaccharide sucralfate could improve symptomatic relief of radiation mucositis over a popular combination of Maalox, diphenhyrdramine and viscous lidocaine alone. Methods: A double-blind study was conducted in which nurses/pharmacists coded patient groups and distributed medication in a manner blinded to both the patients and physicians. Eligible patients receiving radiation to the head and neck and/or chest sites that included the esophagus were randomized to a standard combination of Maalox, diphenhydramime and viscous lidocaine verses the same solution plus sucralfate. Eligible patients were those receiving > 40 Gy at 1.8 Gy/fraction, 1 fraction/day, 5 fractions/week. Participating patients were stratified between chest, small field head and neck, and large field head and neck. Baseline information regarding use of tobacco, alcohol, and food intake was obtained prior to symptomatic mucositis. This was compared with similar information obtained weekly once symptoms occurred. The patients subjected evaluation of throat soreness and relief with medication was elicited as well as physician observations and smears for Candidiasis screening. Medication was prescribed when the patient became symptomatic and concomitant use of other locally effective non-study agents was not allowed. Subjective soreness was graded on a scale of 0-20 with 0 indicating no soreness and 20 designating severe soreness that compromised ability to swallow secretions. The ability to eat various consistency of foods was graded 0-5 with 5 indicating no compromise of ability to ingest a food compared to baseline. Statistical analysis included mean + S.D. for food and soreness scores, paired t-test and two-way analyses of variance to evaluate effects of site and treatment group on the changes in scores. Results: Over 2 years, 110 patients were entered. Since some withdrew and others did not require medication, results are presented for

  4. Radiation hardness tests of double-sided 3D strip sensors with passing-through columns

    Energy Technology Data Exchange (ETDEWEB)

    Dalla Betta, Gian-Franco, E-mail: gianfranco.dallabetta@unitn.it [Dipartimento di Ingegneria Industriale, Università degli Studi di Trento, Via Sommarive 9, I-38123 Trento (Italy); INFN TIFPA, Via Sommarive 14, I-38123 Trento (Italy); Betancourt, Christopher [Institute of Physics, University of Freiburg, Hermann-Herder-Str. 3, 79104 Freiburg (Germany); Boscardin, Maurizio; Giacomini, Gabriele [Fondazione Bruno Kessler, Centro per i Materiali e i Microsistemi (FBK-CMM), Via Sommarive 18, I-38123 Trento (Italy); Jakobs, Karl; Kühn, Susanne [Institute of Physics, University of Freiburg, Hermann-Herder-Str. 3, 79104 Freiburg (Germany); Lecini, Besnik [Dipartimento di Ingegneria Industriale, Università degli Studi di Trento, Via Sommarive 9, I-38123 Trento (Italy); Mendicino, Roberto [Dipartimento di Ingegneria Industriale, Università degli Studi di Trento, Via Sommarive 9, I-38123 Trento (Italy); INFN TIFPA, Via Sommarive 14, I-38123 Trento (Italy); Mori, Riccardo; Parzefall, Ulrich [Institute of Physics, University of Freiburg, Hermann-Herder-Str. 3, 79104 Freiburg (Germany); Povoli, Marco [Dipartimento di Ingegneria Industriale, Università degli Studi di Trento, Via Sommarive 9, I-38123 Trento (Italy); Thomas, Maira [Institute of Physics, University of Freiburg, Hermann-Herder-Str. 3, 79104 Freiburg (Germany); Zorzi, Nicola [Fondazione Bruno Kessler, Centro per i Materiali e i Microsistemi (FBK-CMM), Via Sommarive 18, I-38123 Trento (Italy)

    2014-11-21

    This paper deals with a radiation hardness study performed on double-sided 3D strip sensors with passing-through columns. Selected results from the characterization of the irradiated sensors with a beta source and a laser setup are reported and compared to pre-irradiation results and to TCAD simulations. The sensor performance in terms of signal efficiency is found to be in good agreement with that of other 3D sensors irradiated at the same fluences and tested under similar experimental conditions. - Highlights: • We report results from 3D silicon strip detectors irradiated up to HL-LHC fluences. • I–V curves, noise, charge collection measurements and laser scans are shown. • In all sensors, signals are distinguished from the noise already at low voltage. • Signal efficiency is in agreement with values expected from the electrode geometry. • Efficiency and spatial uniformity would benefit from higher operation voltages.

  5. Radiation hardness tests of double-sided 3D strip sensors with passing-through columns

    International Nuclear Information System (INIS)

    Dalla Betta, Gian-Franco; Betancourt, Christopher; Boscardin, Maurizio; Giacomini, Gabriele; Jakobs, Karl; Kühn, Susanne; Lecini, Besnik; Mendicino, Roberto; Mori, Riccardo; Parzefall, Ulrich; Povoli, Marco; Thomas, Maira; Zorzi, Nicola

    2014-01-01

    This paper deals with a radiation hardness study performed on double-sided 3D strip sensors with passing-through columns. Selected results from the characterization of the irradiated sensors with a beta source and a laser setup are reported and compared to pre-irradiation results and to TCAD simulations. The sensor performance in terms of signal efficiency is found to be in good agreement with that of other 3D sensors irradiated at the same fluences and tested under similar experimental conditions. - Highlights: • We report results from 3D silicon strip detectors irradiated up to HL-LHC fluences. • I–V curves, noise, charge collection measurements and laser scans are shown. • In all sensors, signals are distinguished from the noise already at low voltage. • Signal efficiency is in agreement with values expected from the electrode geometry. • Efficiency and spatial uniformity would benefit from higher operation voltages

  6. Radiation transport Part B: Applications with examples

    International Nuclear Information System (INIS)

    Beutler, D.E.

    1997-01-01

    In the previous sections Len Lorence has described the need, theory, and types of radiation codes that can be applied to model the results of radiation effects tests or working environments for electronics. For the rest of this segment, the author will concentrate on the specific ways the codes can be used to predict device response or analyze radiation test results. Regardless of whether one is predicting responses in a working or test environment, the procedures are virtually the same. The same can be said for the use of 1-, 2-, or 3-dimensional codes and Monte Carlo or discrete ordinates codes. No attempt is made to instruct the student on the specifics of the code. For example, the author will not discuss the details, such as the number of meshes, energy groups, etc. that are appropriate for a discrete ordinates code. For the sake of simplicity, he will restrict himself to the 1-dimensional code CEPXS/ONELD. This code along with a wide variety of other radiation codes can be obtained form the Radiation Safety Information Computational Center (RSICC) for a nominal handling fee

  7. NASDA technician test real-time radiation monitoring device

    Science.gov (United States)

    1997-01-01

    A technician from the National Space Development Agency of Japan (NASDA) tests the real-time radiation monitoring device on SPACEHAB at Kennedy Space Center in preparation for the STS-89 mission, slated to be the first Shuttle launch of 1998. STS-89 will be the eighth of nine scheduled Mir dockings and will include a double module of SPACEHAB, used mainly as a large pressurized cargo container for science, logistical equipment and supplies to be exchanged between the orbiter Endeavour and the Russian Space Station Mir. The nine-day flight of STS-89 also is scheduled to include the transfer of the seventh American to live and work aboard the Russian orbiting outpost. Liftoff of Endeavour and its seven-member crew is targeted for Jan. 15, 1998, at 1:03 a.m. EDT from Launch Pad 39A.

  8. How does the mass media report and interpret radiation data? The results of media content analysis

    Energy Technology Data Exchange (ETDEWEB)

    Perko, T. [Belgian Nuclear Research Centre SCK.CEN, Institute for Environment Health and Safety (Belgium); Cantone, M.C. [University of Milano, Faculty of Medicine (Italy); Tomkiv, Y. [Norwegian University of Life Sciences (Norway); Prezelj, I. [University of Ljubljana, Faculty of Social Sciences (Slovenia); Gallego, E. [Universidad Politecnica de Madrid (Spain); Melekhova, E. [Russian Academy of Sciences in Moscow (Russian Federation)

    2014-07-01

    In communication with the general population, experts often provide quantitative information related to ionizing radiation, expressed with different units of radioactivity. However, quantitative information about radiation risks may be meaningful only to people who have the ability to comprehend basic numerical concepts and possess knowledge related to radiation. Thus, the media, as a bridge between experts and the general population, has to 'translate' quantitative information into a qualitative one. How successful and accurate are the mass media in this transformation of scientific results into publicly understandable information? Our research investigates media reporting on the concept of ionizing radiation in a case of nuclear emergencies. The presentation is focused on summarizing the 'lessons learned' from the use of radiation data in media reporting about the Fukushima nuclear accident. The in-depth media content analysis was conducted in twelve quality newspapers in Belgium, Slovenia, Italy, Spain, Norway and Russia using the same scientific methodology and analyzing the same time period. Preliminary results identified miss concepts of radiation data by media and even within emergency responders and decision makers. The research is a result of FP7 project Innovative integrated tools and platforms for radiological emergency preparedness and post-accident response in Europe - PREPARE and upgraded with a Russian experience. Document available in abstract form only. (authors)

  9. Olsalazine is contraindicated during pelvic radiation therapy: results of a double-blind, randomized clinical trial

    International Nuclear Information System (INIS)

    Martenson, James A.; Hyland, Glenn; Moertel, Charles G.; Mailliard, James A.; O'Fallon, Judith R.; Collins, Roger T.; Morton, Roscoe F.; Tewfik, Hamed H.; Moore, Randy L.; Frank, Albert R.; Urias, Rodolfo E.; Deming, Richard L.

    1996-01-01

    Purpose: A randomized clinical trial from Great Britain suggested a possible beneficial effect of acetylsalicylate in the prevention of radiation-induced bowel toxicity. Olsalazine is an orally administered drug designed to deliver 5-aminosalicylate to the large bowel with minimal systemic absorption. A randomized clinical trial was undertaken to assess the effectiveness of olsalazine in preventing acute diarrhea in patients receiving pelvic radiation therapy. Methods and Materials: Patients receiving pelvic radiation therapy were randomized, in double-blind fashion, to olsalazine 250 mg, two capsules twice daily, or an identical appearing placebo, two capsules twice daily. Patients were then evaluated weekly during radiation therapy for the primary study endpoint, diarrhea, as well as rectal bleeding, abdominal cramping, and tenesmus. Results: The study was closed early, after entry of 58 evaluable patients, when a preliminary analysis showed excessive diarrhea in patients randomized to olsalazine. The incidence and severity of diarrhea were worse in patients randomized to olsalazine (p 0.0036). Sixty percent of the patients randomized to olsalazine experienced Grade 3 or 4 diarrhea compared to only 14% randomized to placebo. There was also a trend toward higher incidence and greater severity of abdominal cramping in patients who were randomized to olsalazine (p = 0.084). Conclusion: Administration of olsalazine during pelvic radiation therapy resulted in an increased incidence and severity of diarrhea. Olsalazine is contraindicated in patients receiving pelvic radiation therapy

  10. Radiation Damage in Electronic Memory Devices

    Directory of Open Access Journals (Sweden)

    Irfan Fetahović

    2013-01-01

    Full Text Available This paper investigates the behavior of semiconductor memories exposed to radiation in order to establish their applicability in a radiation environment. The experimental procedure has been used to test radiation hardness of commercial semiconductor memories. Different types of memory chips have been exposed to indirect ionizing radiation by changing radiation dose intensity. The effect of direct ionizing radiation on semiconductor memory behavior has been analyzed by using Monte Carlo simulation method. Obtained results show that gamma radiation causes decrease in threshold voltage, being proportional to the absorbed dose of radiation. Monte Carlo simulations of radiation interaction with material proved to be significant and can be a good estimation tool in probing semiconductor memory behavior in radiation environment.

  11. Explanation of test and assessment of chromosomal aberrations on occupational health examinations for radiation workers

    International Nuclear Information System (INIS)

    Lu Yumin; Fu Baohua; Han Lin; Wang Xi'ai; Zhao Fengling

    2012-01-01

    Test and Assessment of Chromosomal Aberrations on Occupational Health Examinations for Radiation Workers was formulated for standardizing analysis and outcome assessment of chromosomal aberrations on occupational health examinations for radiation workers. In order to provide experimental and theoretical basis for implementation and extension of this standard, this paper interpreted the standard comprehensively, including some existed problems that methods on detection and outcome assessment of chromosomal aberrations is not unified in different laboratories in China, and related criteria,laws and regulations at home and abroad are not fit for the detection of chromosomal aberrations for radiation workers very well; some introduction on methods of chromosomal slide preparation, discriminant analysis and outcome assessment of chromosomal aberration; and some influencing factors in the quality of chromosomal aberration detection. (authors)

  12. Some results of radiative balance in atmospheres with clouds

    International Nuclear Information System (INIS)

    Anduckia Avila, Juan Carlos; Pelkowski, Joaquin

    2000-01-01

    Vertical profiles of temperature for a semi grey three-Layer atmosphere are established using a radiative equilibrium condition. The approximation contains the greenhouse effect, scattering by clouds in one direction and isotropic diffuse reflection at the planet's surface. Absorption of short- wave radiation is also considered in one of the three layers. Similar models are contained therein

  13. Mathematics Placement Test: Typical Results with Unexpected Outcomes

    Science.gov (United States)

    Ingalls, Victoria

    2011-01-01

    Based on the results of a prior case-study analysis of mathematics placement at one university, the mathematics department developed and piloted a mathematics placement test. This article describes the implementation process for a mathematics placement test and further analyzes the test results for the pilot group. As an unexpected result, the…

  14. Test Results of PBMR Fuel Spheres

    International Nuclear Information System (INIS)

    Koshcheev, Konstantin; Diakov, Alexander; Beltyukov, Igor; Barybin, Andrey; Chernetsov, Mikhail

    2014-01-01

    Results of pre-irradiation testing of fuel spheres (FS) and coated particles (CP) manufactured by PBMR SOC (Republic of South Africa) are described. The stable high quality level of major characteristics (dimensions, CP coating structure, uranium-235 contamination of the FS matrix graphite and the outer PyC layer of the CP coating) are shown. Results of a methodical irradiation test of two FS in helium and neon medium at temperatures of 800 to 1300 °C with simultaneous determination of release-to-birth ratios for major gaseous fission products (GFP) are described. (author)

  15. Results of interlaboratory tests regarding TXRF

    International Nuclear Information System (INIS)

    Klockenkaemper, R.; Bohlen, A. von

    2000-01-01

    Interlaboratory or intercomparison tests can be performed for proficiency testing of individual laboratories, for the certification of a special sample material and for the validation of a certain method. We participated in two interlaboratory tests in order to validate total reflection x-ray fluorescence analysis (TXRF). We used our results to evaluate TXRF and to compare it with other competing methods, particularly with respect of precision and accuracy. The first interlaboratory test was organized by IAEA (International Atomic Energy Agency, Vienna, Austria). As a candidate for reference material, a lichen (IAEA-336 Lichen) was distributed among 27 participants. In our laboratory, the powdered biogenic material was digested with nitric acid under high pressure and analyzed by TXRF. - The second interlaboratory test was organized by IRMM (Institute for Reference Materials and Measurements, Geel, Belgium). As a certified test sample with undisclosed values, a sediment (IMEP-14) was delivered to 220 laboratories. We digested the geogenic material again by nitric acid and additionally by hydrofluoric acid and analyzed it by TXRF. - In both test samples, six or eight different trace elements, respectively, were determined by TXRF with a content between 2 and 2000 mg/kg. Calibration was carried out by internal standardization. For that purpose, Ga or Se, respectively, was added as standard element. The measurement uncertainty of TXRF was estimated by the method of error propagation. In our paper we will report on the results of the two interlaboratory tests. It will be shown that TXRF is highly reliable for a correct determination of trace elements in biogenic and geogenic samples. It is competitive with the established methods of trace analyses which were involved in these tests and it is even superior to them in certain aspects. (author)

  16. Standard Practice for Dosimetry of Proton Beams for use in Radiation Effects Testing of Electronics

    Energy Technology Data Exchange (ETDEWEB)

    McMahan, Margaret A.; Blackmore, Ewart; Cascio, Ethan W.; Castaneda, Carlos; von Przewoski, Barbara; Eisen, Harvey

    2008-07-25

    Representatives of facilities that routinely deliver protons for radiation effect testing are collaborating to establish a set of standard best practices for proton dosimetry. These best practices will be submitted to the ASTM International for adoption.

  17. Standard Practice for Dosimetry of Proton Beams for use in Radiation Effects Testing of Electronics

    International Nuclear Information System (INIS)

    McMahan, Margaret A.; Blackmore, Ewart; Cascio, Ethan W.; Castaneda, Carlos; von Przewoski, Barbara; Eisen, Harvey

    2008-01-01

    Representatives of facilities that routinely deliver protons for radiation effect testing are collaborating to establish a set of standard best practices for proton dosimetry. These best practices will be submitted to the ASTM International for adoption

  18. Intensity modulated radiation therapy: Analysis of patient specific quality control results, experience of Rene-Gauducheau Centre

    International Nuclear Information System (INIS)

    Chiavassa, S.; Brunet, G.; Gaudaire, S.; Munos-Llagostera, C.; Delpon, G.; Lisbona, A.

    2011-01-01

    Purpose. - Systematic verifications of patient's specific intensity-modulated radiation treatments are usually performed with absolute and relative measurements. The results constitute a database which allows the identification of potential systematic errors. Material and methods. - We analyzed 1270 beams distributed in 232 treatment plans. Step-and-shoot intensity-modulated radiation treatments were performed with a Clinac (6 and 23 MV) and sliding window intensity-modulated radiation treatments with a Novalis (6 MV). Results. - The distributions obtained do not show systematic error and all the control meet specified tolerances. Conclusion. - These results allow us to reduce controls specific patients for treatments performed under identical conditions (location, optimization and segmentation parameters of treatment planning system, etc.). (authors)

  19. Mobile evaporator corrosion test results

    International Nuclear Information System (INIS)

    Rozeveld, A.; Chamberlain, D.B.

    1997-05-01

    Laboratory corrosion tests were conducted on eight candidates to select a durable and cost-effective alloy for use in mobile evaporators to process radioactive waste solutions. Based on an extensive literature survey of corrosion data, three stainless steel alloys (304L, 316L, AL-6XN), four nickel-based alloys (825, 625, 690, G-30), and titanium were selected for testing. The corrosion tests included vapor phase, liquid junction (interface), liquid immersion, and crevice corrosion tests on plain and welded samples of candidate materials. Tests were conducted at 80 degrees C for 45 days in two different test solutions: a nitric acid solution. to simulate evaporator conditions during the processing of the cesium ion-exchange eluant and a highly alkaline sodium hydroxide solution to simulate the composition of Tank 241-AW-101 during evaporation. All of the alloys exhibited excellent corrosion resistance in the alkaline test solution. Corrosion rates were very low and localized corrosion was not observed. Results from the nitric acid tests showed that only 316L stainless steel did not meet our performance criteria. The 316L welded interface and crevice specimens had rates of 22.2 mpy and 21.8 mpy, respectively, which exceeds the maximum corrosion rate of 20 mpy. The other welded samples had about the same corrosion resistance as the plain samples. None of the welded samples showed preferential weld or heat-affected zone (HAZ) attack. Vapor corrosion was negligible for all alloys. All of the alloys except 316L exhibited either open-quotes satisfactoryclose quotes (2-20 mpy) or open-quotes excellentclose quotes (<2 mpy) corrosion resistance as defined by National Association of Corrosion Engineers. However, many of the alloys experienced intergranular corrosion in the nitric acid test solution, which could indicate a susceptibility to stress corrosion cracking (SCC) in this environment

  20. SSPM based radiation sensing: Preliminary laboratory and clinical results

    International Nuclear Information System (INIS)

    Konnoff, Daniel C.; Plant, Thomas K.; Shiner, Elizabeth

    2011-01-01

    Recent Solid State Photomultiplier (SSPM) technology has matured, reaching a performance level that is suitable for replacement of the ubiquitous photomultiplier tube in selected applications for environmental radiation monitoring, clinical dosimetry, and medical imaging purposes. The objective of this work is low signal level laboratory and high signal level clinical testing of the Hamamatsu MPPC (S10362-11-050C), Photonique SSPM (0810G1), and Voxtel SiPM (SQBF-EKAA/SQBF-EIOA) SSPMs coupled to different inorganic scintillator crystals (Prelude 420, BGO), inorganic doped glass scintillator material SiO 2 :Cu 2+ and organic BCF-12 plastic scintillating fibers, used as detector elements. Plastic Optical Fibers (POFs) and Glass Optical Fibers (GOFs) are used as signal conduits for laboratory and clinical testing. Further, reduction of electron-beam-generated Cerenkov light in optical fibers is facilitated by the inclusion of metalized air-core capillary tubing between the BCF-12 plastic scintillating fiber and the POF. In a clinical setting dose linearity, percent depth dose, and angular measurements for 6 MV/18 MV photon beams and 9 MeV electron beams are compared with and without the use of the air-core capillary tubing for BCF-12 plastic scintillating fiber. These same measurements are repeated for SiO 2 :Cu 2+ scintillator material without air-core capillary tubing.