WorldWideScience

Sample records for radiations des detecteurs

  1. Studying radiative B decays with the Atlas detector; Etude des desintegrations radiatives des mesons B dans le detecteur ATLAS

    Energy Technology Data Exchange (ETDEWEB)

    Viret, S

    2004-09-01

    This thesis is dedicated to the study of radiative B decays with the ATLAS detector at the LHC (large hadron collider). Radiative decays belong to the rare decays family. Rare decays transitions involve flavor changing neutral currents (for example b {yields} s{gamma}), which are forbidden at the lowest order in the Standard Model. Therefore these processes occur only at the next order, thus involving penguin or box diagrams, which are very sensitive to 'new physics' contributions. The main goal of our study is to show that it would be possible to develop an online selection strategy for radiative B decays with the ATLAS detector. To this end, we have studied the treatment of low energy photons by the ATLAS electromagnetic calorimeter (ECal). Our analysis shows that ATLAS ECal will be efficient with these particles. This property is extensively used in the next section, where a selection strategy for radiative B decays is proposed. Indeed, we look for a low energy region of interest in the ECal as soon as the level 1 of the trigger. Then, photon identification cuts are performed in this region at level 2. However, a large part of the proposed selection scheme is also based on the inner detector, particularly at level 2. The final results show that large amounts of signal events could be collected in only one year by ATLAS. A preliminary significance (S/{radical}B) estimation is also presented. Encouraging results concerning the observability of exclusive radiative B decays are obtained. (author)

  2. Studying radiative B decays with the Atlas detector; Etude des desintegrations radiatives des mesons B dans le detecteur ATLAS

    Energy Technology Data Exchange (ETDEWEB)

    Viret, S

    2004-09-01

    This thesis is dedicated to the study of radiative B decays with the ATLAS detector at the LHC (large hadron collider). Radiative decays belong to the rare decays family. Rare decays transitions involve flavor changing neutral currents (for example b {yields} s{gamma}), which are forbidden at the lowest order in the Standard Model. Therefore these processes occur only at the next order, thus involving penguin or box diagrams, which are very sensitive to 'new physics' contributions. The main goal of our study is to show that it would be possible to develop an online selection strategy for radiative B decays with the ATLAS detector. To this end, we have studied the treatment of low energy photons by the ATLAS electromagnetic calorimeter (ECal). Our analysis shows that ATLAS ECal will be efficient with these particles. This property is extensively used in the next section, where a selection strategy for radiative B decays is proposed. Indeed, we look for a low energy region of interest in the ECal as soon as the level 1 of the trigger. Then, photon identification cuts are performed in this region at level 2. However, a large part of the proposed selection scheme is also based on the inner detector, particularly at level 2. The final results show that large amounts of signal events could be collected in only one year by ATLAS. A preliminary significance (S/{radical}B) estimation is also presented. Encouraging results concerning the observability of exclusive radiative B decays are obtained. (author)

  3. Mesure des champs de radiation dans le detecteur ATLAS et sa caverne avec les detecteurs au silicium a pixels ATLAS-MPX

    Science.gov (United States)

    Bouchami, Jihene

    The LHC proton-proton collisions create a hard radiation environment in the ATLAS detector. In order to quantify the effects of this environment on the detector performance and human safety, several Monte Carlo simulations have been performed. However, direct measurement is indispensable to monitor radiation levels in ATLAS and also to verify the simulation predictions. For this purpose, sixteen ATLAS-MPX devices have been installed at various positions in the ATLAS experimental and technical areas. They are composed of a pixelated silicon detector called MPX whose active surface is partially covered with converter layers for the detection of thermal, slow and fast neutrons. The ATLAS-MPX devices perform real-time measurement of radiation fields by recording the detected particle tracks as raster images. The analysis of the acquired images allows the identification of the detected particle types by the shapes of their tracks. For this aim, a pattern recognition software called MAFalda has been conceived. Since the tracks of strongly ionizing particles are influenced by charge sharing between adjacent pixels, a semi-empirical model describing this effect has been developed. Using this model, the energy of strongly ionizing particles can be estimated from the size of their tracks. The converter layers covering each ATLAS-MPX device form six different regions. The efficiency of each region to detect thermal, slow and fast neutrons has been determined by calibration measurements with known sources. The study of the ATLAS-MPX devices response to the radiation produced by proton-proton collisions at a center of mass energy of 7 TeV has demonstrated that the number of recorded tracks is proportional to the LHC luminosity. This result allows the ATLAS-MPX devices to be employed as luminosity monitors. To perform an absolute luminosity measurement and calibration with these devices, the van der Meer method based on the LHC beam parameters has been proposed. Since the ATLAS

  4. Measurement and analysis of high energy radiation through activation detectors. Application in dosimetry; Sur la mesure et l'analyse des rayonnements de haute energie par detecteurs a activation. Application a la dosimetrie

    Energy Technology Data Exchange (ETDEWEB)

    Sklavenitis, L. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-10-15

    This work is concerned with the possibility of measurement and analysis of radiation fluences within objects of small volume submitted to a high energy proton beam. The first part, consecrated to the establishment of a method of analysis, comprises a detailed study of the radiation nature and energy spectra as well as of the various dosimetry methods. In order to select a group of detectors, high energy nuclear reactions were systematically studied and for some of them cross sections were measured or calculated: for example the cross section of the reaction {sup 11}B (p,n) {sup 11}C between 150 and 3000 MeV and of the reaction {sup 34}S (p,2pn) {sup 32}P between 50 and 3000 MeV. The second part is relative to the application of the fore-mentioned analysis to radiation within a tissue equivalent phantom irradiated by 3 GeV protons. This analysis is sufficiently detailed to allow the reconstitution of the absorbed doses, the dose equivalent and, contingent on a better knowledge of the dose due to heavy particles, the quality factors. It allowed also to follow the evolution of the various dosimetric data as a function of the depth inside the phantom and to verify calculations already done by other researchers. The comparison of the measured doses and the corresponding detector activities revealed the possibility that some detectors could give directly the absorbed dose, or even the dose equivalent, by a simple activity measurement. (author) [French] Le travail porte sur la possibilite de mesure et d'analyse, a l'aide de detecteurs a activation, des fluences de rayonnements a l'interieur d'un objet de petit volume soumis a un faisceau de protons de tres haute energie. La premiere partie, consacree a la mise au point de la methode d'analyse des fluences, comporte une etude detaillee de la nature des rayonnements et de leurs spectres energetiques ainsi que des differentes methodes de dosimetrie. Pour arriver au choix d'un groupe de

  5. Measurement and analysis of high energy radiation through activation detectors. Application in dosimetry; Sur la mesure et l'analyse des rayonnements de haute energie par detecteurs a activation. Application a la dosimetrie

    Energy Technology Data Exchange (ETDEWEB)

    Sklavenitis, L [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-10-15

    This work is concerned with the possibility of measurement and analysis of radiation fluences within objects of small volume submitted to a high energy proton beam. The first part, consecrated to the establishment of a method of analysis, comprises a detailed study of the radiation nature and energy spectra as well as of the various dosimetry methods. In order to select a group of detectors, high energy nuclear reactions were systematically studied and for some of them cross sections were measured or calculated: for example the cross section of the reaction {sup 11}B (p,n) {sup 11}C between 150 and 3000 MeV and of the reaction {sup 34}S (p,2pn) {sup 32}P between 50 and 3000 MeV. The second part is relative to the application of the fore-mentioned analysis to radiation within a tissue equivalent phantom irradiated by 3 GeV protons. This analysis is sufficiently detailed to allow the reconstitution of the absorbed doses, the dose equivalent and, contingent on a better knowledge of the dose due to heavy particles, the quality factors. It allowed also to follow the evolution of the various dosimetric data as a function of the depth inside the phantom and to verify calculations already done by other researchers. The comparison of the measured doses and the corresponding detector activities revealed the possibility that some detectors could give directly the absorbed dose, or even the dose equivalent, by a simple activity measurement. (author) [French] Le travail porte sur la possibilite de mesure et d'analyse, a l'aide de detecteurs a activation, des fluences de rayonnements a l'interieur d'un objet de petit volume soumis a un faisceau de protons de tres haute energie. La premiere partie, consacree a la mise au point de la methode d'analyse des fluences, comporte une etude detaillee de la nature des rayonnements et de leurs spectres energetiques ainsi que des differentes methodes de dosimetrie. Pour arriver au choix d'un groupe de detecteurs, une etude systematique des

  6. Study of thick, nuclear-compensated silicon detectors; Etude des detecteurs epais au silicium compense nucleairement

    Energy Technology Data Exchange (ETDEWEB)

    Le Coroller, Y. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-09-01

    A study is made here, from the point of view of the realization and the performance, of thick nuclear-compensated silicon detectors. After recalling the need for compensation and reviewing the existing methods, the author describes in detail the controlled realization of thick detectors by nuclear compensation from the theoretical and experimental points of view. The practical precautions which should be observed are given: control of the homogeneity of the starting material, control of the evolution of the compensation, elimination of parasitic processes. The performances of the detectors obtained are then studied: electrical characteristics (current, life-time) on the one hand, detection and spectrometry of penetrating radiations on the other hand. The results show, that the compensated diodes having an effective thickness of two millimeters operate satisfactorily as detectors for applied voltages of about 500 volts. The resolutions observed are then about 2 per cent for mono-energetic electrons and about 4 per cent for the gamma; they can be improved by the use of a pre-amplifier of very low background noise. (author) [French] Les detecteurs epais au silicium compense nucleairement sont etudies ici du double point de vue realisation et performances. Apres un rappel sur la necessite de la compensation et les procedes existants, la realisation controlee des detecteurs epais par compensation nucleaire est decrite en detail sous l'aspect theorique et l'aspect experimental. On met en evidence les precautions a prendre dans la pratique: controle de l'homogeneite du materiau de base, controle de l'evolution de la compensation, elimination des processus parasites. On etudie ensuite les performances de detecteurs obtenus : caracteristiques electriques (courant, duree de vie) d'une part, d'autre part detection et spectrometrie des rayonnements penetrants. Les resultats montrent que les diodes compensees ayant une epaisseur utile de deux

  7. Study of thick, nuclear-compensated silicon detectors; Etude des detecteurs epais au silicium compense nucleairement

    Energy Technology Data Exchange (ETDEWEB)

    Le Coroller, Y [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-09-01

    A study is made here, from the point of view of the realization and the performance, of thick nuclear-compensated silicon detectors. After recalling the need for compensation and reviewing the existing methods, the author describes in detail the controlled realization of thick detectors by nuclear compensation from the theoretical and experimental points of view. The practical precautions which should be observed are given: control of the homogeneity of the starting material, control of the evolution of the compensation, elimination of parasitic processes. The performances of the detectors obtained are then studied: electrical characteristics (current, life-time) on the one hand, detection and spectrometry of penetrating radiations on the other hand. The results show, that the compensated diodes having an effective thickness of two millimeters operate satisfactorily as detectors for applied voltages of about 500 volts. The resolutions observed are then about 2 per cent for mono-energetic electrons and about 4 per cent for the gamma; they can be improved by the use of a pre-amplifier of very low background noise. (author) [French] Les detecteurs epais au silicium compense nucleairement sont etudies ici du double point de vue realisation et performances. Apres un rappel sur la necessite de la compensation et les procedes existants, la realisation controlee des detecteurs epais par compensation nucleaire est decrite en detail sous l'aspect theorique et l'aspect experimental. On met en evidence les precautions a prendre dans la pratique: controle de l'homogeneite du materiau de base, controle de l'evolution de la compensation, elimination des processus parasites. On etudie ensuite les performances de detecteurs obtenus : caracteristiques electriques (courant, duree de vie) d'une part, d'autre part detection et spectrometrie des rayonnements penetrants. Les resultats montrent que les diodes compensees ayant une epaisseur utile de deux millimetres fonctionnent

  8. Thermal, intermediate and fast neutron flux measurements using activation detectors; Mesure des flux de neutrons thermiques, intermediaires et rapides au moyen de detecteurs par activation

    Energy Technology Data Exchange (ETDEWEB)

    Brisbois, J; Lott, M; Manent, G [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1964-07-01

    The problem of neutron flux measurements using activation detectors is studied in the particular case of protection research. It is shown how it possible, it is possible, using a known thermal flux, to organise a coherent calibration system for all the detectors. The rapid neutron detectors are calibrated with respect to a reference detector (phosphorus) in a natural uranium converter; the intermediate neutron detectors with respect to gold in the axial channel of ZOE. This method makes it possible to minimise the errors due to the activation cross-sections. A brief description is given of the counting room of the Pile Safety Study Service, as well of the practical utilisation characteristics of the counters employed. (authors) [French] Le probleme de la mesure des flux de neutrons au moyen de detecteurs par activation est etudie dans le cas particulier des etudes de protections. On montre comment, a partir d'un flux thermique connu, on peut organiser un systeme coherent d'etalonnage de tous les detecteurs. Les detecteurs de neutrons rapides sont etalonnes par rapport a un detecteur de reference (phosphore) dans un convertisseur en uranium naturel; les detecteurs de neutrons intermediaires, par rapport a l'or dans le canal axial de ZOE, Cette methode permet de minimiser les erreurs dues aux sections efficaces d'activation. On decrit sommairement la salle de comptage du Service d'Etudes de Protections de Piles et on indique les caracteristiques d'emploi pratique des detecteurs utilises. (auteurs)

  9. Germanium junction detectors. Theoretical and practical factors governing their use in radiation spectrometry; Detecteurs a jonction au germanium. Elements theoriques et pratiques pour l'utilisation en spectrometrie de rayonnements

    Energy Technology Data Exchange (ETDEWEB)

    Hors, M; Philis, C [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    Semi-conductor detectors have recently greatly increased the possibilities available to nuclear spectroscopists for the study of {alpha}, {beta} and {gamma} radiations. Their use in radio-chemistry has encouraged us to study their principle, their mechanism and also the conditions under which they can be used. The first part, which is theoretical, consists of a summary of what should be known concerning the best use of junction detectors, in particular Ge (Li) detectors. The second part, which is experimental, summarizes the laboratory work carried out over a period of one year on Ge (Li) detectors. Stress is laid on the possibilities presented by the use of these detectors as photo-electric spectrometers, and also on the precautions required. Amongst the numerous results presented, the resolution of 2.52 keV obtained for the {gamma} radiation of 145.5 keV for {sup 141}Ce may be particularly noted. (authors) [French] Les detecteurs a semi-conducteurs ont recemment accru les possibilites offertes aux spectroscopistes nucleaires pour l'etude des radiations {alpha}, {beta}, {gamma}. Leurs utilisations en radiochimie nous ont incite a en etudier le principe, le mecanisme et d'autre part les conditions d'emploi. La premiere partie, theorique, rappelle l'essentiel de ce qu'il est utile de connaitre pour une utilisation optimale des detecteurs a jonctions et en particulier des detecteurs Ge (Li). La deuxieme partie, experimentale, resume les travaux realises au laboratoire pendant un an avec des detecteurs Ge (Li). Nous insistons sur les possibilites offertes et les precautions a prendre dans l'utilisation de ces detecteurs comme spectrometres photoelectriques. Parmi les nombreux resultats presentes, citons la resolution de 2,52 keV obtenue pour le rayonnement {gamma} de 145 f5 keV du {sup 141}Ce. (auteurs)

  10. Description of methods for making activation detectors for use in nuclear reactors; Description des procedes de fabrication des detecteurs d'activation utilises dans les reacteurs nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Barbalat, R; Le Coguie, R; Leger, P; Salon, L; Thierry, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1968-07-01

    A brief description of methods currently used for making activation detectors, thin films and various deposits used in nuclear reactors. The thicknesses required vary from about a few tenths of a micron to a few tenths of a millimeter. Different techniques are used for fixing the large variety of elements: rolling, moulding, painting, electrolysis, vacuum deposition, thin films, wires, enamels, protective linings, etc. (authors) [French] Expose succinct des procedes actuellement mis en oeuvre pour la realisation des detecteurs d'activation, feuilles minces et depots divers utilises dans les reacteurs nucleaires. La gamme des epaisseurs necessaires s'etendant approximativement des dixiemes de micrometre aux dixiemes de millimetre. La diversite des elements a fixer justifiant les techniques differentes selon les cas: laminage, moulage, peinture, electrolyse, depot sous vide, couches minces, fils, emaux, revetements protecteurs, etc. (auteurs)

  11. Determination of the flux per electron-volt at the resonance energy of gold by means op thick gold detectors (1962); Determination des flux par electron-volt a l'energie de resonance de l'or a l'aide de detecteurs d'or epais. (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Brisbois, J; Fogagnolo, G [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1962-07-01

    We calculated the coefficients which allow determining a neutron flux at 5 eV by means of 2/10 mm thick gold detectors on Geiger-Muller counter assemblies. These coefficients were obtained comparing the thick detectors with the thin ones. (authors) [French] Nous avons calcule les coefficients permettant de determiner le flux de neutrons a 5 eV a partir de comptages de detecteurs d'or de 2/10 mm d'epaisseur sur des groupes a compteur de Geiger-Muller. Ces coefficients ont ete obtenus en comparant les detecteurs epais avec des detecteurs minces. (auteurs)

  12. Studies on radiation-image detectors; Etudes sur les detecteurs a images de rayonnements; Izuchenie detektorov izobrazheniya radiatsii; Estudios sobre detectores de radiaciones productores de imagenes

    Energy Technology Data Exchange (ETDEWEB)

    Reiffel, L [Armour Research Foundation, Chicago, IL (United States)

    1962-04-15

    data also germane to scintillation-chamber technology. Possible imaging detectors using thick blocks of material which are capable of significant energy storage and stimulated phosphorescence upon irradiation are discussed briefly along with read-out methods using optical scanning beams to eliminate resolution loss due to finite phosphor thickness. (author) [French] Le memoire decrit les travaux qui ont ete entrepris sur des detecteurs de rayonnements capables de fournir des informations tout a fait exactes sur la distribution spatiale. Il s'agit avant tout de determiner des distributions d'intensites dans un plan, ou eventuellement sur un cylindre. Cette categorie de problemes comprend la diffraction des neutrons, la radiographie des neutrons, ainsi que la radiographie aux rayons X ou {gamma} ou les etudes de diffusion avec ces rayons. L'auteur s'occupe surtout des detecteurs a images de rayonnements, fondes sur la distribution des etincelles et sur la luminescence Ou la phosphorescence stimulee. Le laboratoire de Armour Research a mis au point de tres grands compteurs a etincelles, pesant plus de 100 livres et comportant des zones sensibles de l'ordre de 2000 cm{sup 2}, definies par des assemblages de plans comprenant chacun jusqu'a 400 fils d'anode et de cathode, les anodes et les cathodes etant respectivement disposees en quinconce. Un compteur a courant gazeux contenant de l'air ou un melange d'argon et de methane constitue un systeme sensible aux rayonnements alpha; la detection des neutrons lents se fait avec des plaques en {sup 10}B enrichi. Avec d'autres gaz de remplissage l'appareil est sensible aux protons et aux electrons. La lecture de la distribution d'intensite se fait par enregistrement photographique de la distribution des etincelles. Des diagrammes de taches de Laue ont pu etre enregistres en dix minutes a l'aide du reacteur d'Armour Research fonctionnant a faible puissance; le flux de crete dans le coeur etait de 10{sup 11} n/cm{sup 2} s et le

  13. Methods for determining fast neutron spectra using threshold detectors; Les methodes de determination des spectres de neutrons rapides a l'aide de detecteurs a seuil

    Energy Technology Data Exchange (ETDEWEB)

    Delattre, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    We propose to examine all the methods by which fast neutron spectra can be determined using the response of threshold detectors (activation or fission chamber detectors). Most of these methods have been proposed and often even used by various authors of which a list will be found in the bibliography. The aim of the present report is thus not to present original work but rather to gather into a single article and to present in a rational form a whole series of methods which have already been described in articles scattered throughout the specialised literature. Up to the present, each author has in general studied one or two methods and no comparative study of all the possible methods seems to have been made. The most comprehensive study on this topic is that of P.M. UTHE from whose article much has been borrowed. We have tried here to develop a useful tool which should facilitate the systematic experimental study leading to the recognition of the respective merits of the methods proposed. (author) [French] On se propose d'examiner l'ensemble des methodes permettant de determiner les spectres de neutrons rapides a partir des reponses de detecteurs a seuil (detecteurs par activation ou chambre a fission). La plupart de ces methodes ont deja ete proposees, et souvent meme utilisees, par differents auteurs dont on trouvera la liste en bibliographie. Le but du present rapport n'est donc pas de faire oeuvre originale mais plutot de rassembler dans un meme document et de presenter de maniere homogene toute une serie de methodes qui ont deja fait l'objet d'articles disperses dans la litterature specialisee. Jusqu'a present, chaque auteur s'est en general limite a l'etude experimentale d'une ou deux methodes et aucune etude comparative de l'ensemble des methodes possibles ne semble avoir ete faite. Le rapport le plus complet a ce sujet est celui de P.M. UTHE auquel de larges emprunts ont ete faits. On s'est efforce ici d'elaborer un outil de travail commode qui devrait

  14. Contribution to the study of radio toxicity of aromatic and medicinal plants using solid state nuclear track detectors; Contribution a l etude de la radio toxicite des plantes aromatiques et medicinales au moyen des detecteurs solides de traces nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Mortassim, A; Misdaq, M A; Naaman, A

    2009-07-01

    The concentrations of uranium (238 U), thorium (232 Th), radon (222 Rn) and thoron (220 Rn) were measured in twenty aromatic and medicinal plants in {sup f}ind a new method based on using solid state nuclear track detectors type Cr-39 and Rs-115. He emerges from this study that the verbena and salvia have higher levels of uranium (radon) higher than that of other plants while the leaves of olive and saturja have concentrations of thorium (thoron) higher than other plants therefore radio toxicity of these plants is higher than that of others and may pose a radiological hazard if the masses are incorporated by consumers high. [French] Les concentrations en uranium (238U), thorium (232Th), radon (222Rn), et thoron (220Rn) ont ete mesurees dans vingt plantes aromatiques et medicinales en utilsant une nouvelle methode basee sur l utilisation des detecteurs solides de traces nucleaires de types CR-39 et LR-115. Il en sort de cette etude que la verveine et la salvia presentent des teneurs en uranium (radon) superieurs a celle des autres plantes alors que les feuilles d olivier et la saturja presentent des concentrations en thorium (thoron) plus elevee que celles des autres plantes par consequent la radio toxicite de ces plantes est superieure a celles des autres et peuvent presenter un risque radiologique si les masses incorporees par les consommateurs sont elevees.

  15. Study of problems arising from the use of thermal neutron detectors in a pulsed regime. Application to the development of a digital transferometer adapted to receive signals from these detectors; Etude des problemes poses par l'utilisation des detecteurs de neutrons thermiques fonctionnant en regime impulsionnel. Application a la realisation d'un transferometre numerique adapte aux signaux fournis par ces detecteurs

    Energy Technology Data Exchange (ETDEWEB)

    Le Tilly, Y [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1966-12-01

    The instantaneous value of the counting rate of the pulses given by a fission detector settled in a reactor follows the neutron flux, but it is shown that the counter adds a white noise to the measured signal. This report deals with some possibilities of on line numerical handling afforded by this kind of signals. One considers first the influence of a by N numerical divider and one shows that, acting like a quantifier, it adds to the signal a white noise with the power N{sup 2}/{sub 12}. One, studies afterwards the principle of a digital filter aimed to Fourier analyse the signal. The realization of this device is described. It can be used in transfer function measurements at frequencies below 125 kHz. Some examples of experiments performed with this apparatus are presented. One discusses finally the design, according to the same principle, of a power spectral density analyser in the frequency range 0,01 - 10 000 Hz for random signal of the same kind. (author) [French] La valeur instantanee de la frequence de recurrence des impulsions issues d'un detecteur a fission place dans un reacteur est proportionnelle au flux neutronique. Apres avoir montre que le detecteur ajoute un bruit blanc au signal mesure, on etudie clans ce rapport certaines possibilites de traitement numerique en temps reel offertes par ce type de signaux. On examine d'abord l'influence d'un diviseur numerique par N, et l'on montre que son action, semblable a une quantification, ajoute au signal un bruit blanc de puissance N{sup 2}/{sub 12}. On, etudie ensuite le principe d'un filtre numerique destine a effectuer l'analyse de Fourier du signal, et l'on decrit la realisation de cet appareil qui peut etre utilise pour mesurer des fonctions de transfert a une frequence quelconque inferieure a 10 kHz. Des exemples de mesures faites avec cet appareil sont presentes. On discute enfin la possibilite de realiser suivant le meme principe un analyseur de densite spectrale dans la bande de frequence 0,01 Hz

  16. Improved organic scintillation detectors; Possibilites de perfectionnement des detecteurs organiques a scintillations; Usovershenstvovannye organicheskie stsintillyatsionnye detektory; Detectores organicos de centelleo perfeccionados

    Energy Technology Data Exchange (ETDEWEB)

    Birks, J B [University of Manchester, Manchester (United Kingdom)

    1962-04-15

    Equations have been derived for the practical scintillation efficiency (photo-electrons/MeV) of organic crystals and solutions in terms of molecular parameters and these have been applied to the more important scintillator systems, for photomultipliers with S11 (glass window) and S13 (quartz window) responses. The results suggest several improvements in current organic scintillation detector practice: the use of binary rather than ternary solutions; the use of quartz rather than glass windows; and the reconsideration of mixed crystal scintillators based on naphthalene. Improvements by factors of 2 or more in the figure of merit (practical efficiency/decay time) for fast-scintillation counting can be obtained. (author) [French] L'auteur a etabli des equations pour determiner le rendement de scintillation (photoelectrons/MeV) de cristaux et solutions organiques, en faisant intervenir des parametres moleculaires. Il a applique ces equations a des appareils a scintillations plus importantes pour determiner la reponse des photomultiplicateurs a fenetre en verre (S11) et a fenetre en quartz (S13). Les resultats obtenus ont fait apparaitre la possibilite d'ameliorer, a plusieurs egards, les detecteurs organiques a scintillations du type courant, par exemple en remplacant les solutions ternaires par des solutions binaires, les fenetres en verre par des fenetres en quartz, ou en reexaminant les possibilites offertes par les scintillateurs a cristaux mixtes a base de naphtalene. L'introduction de ces perfectionnements conduirait a une amelioration, du simple au double ou plus, du facteur de qualite (efficacite/temps de decroissance) des dispositifs de comptage a scintillations. (author) [Spanish] Se han establecido ecuaciones que permiten calcular el rendimiento practico de centelleo (fotoelectrones/MeV) de los cristales y soluciones organicos en funcion de parametros moleculares; estas ecuaciones han sido aplicadas a los sistemas de centelleo mas importantes, para

  17. Consideration of the problems of the separate measurement of {beta}, {gamma} and X radiation; Considerations sur les problemes de la dosimetrie individuelle des radiations {beta}, {gamma}, X

    Energy Technology Data Exchange (ETDEWEB)

    Joffre, H [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-07-01

    After outlining the present state of knowledge concerning the determination of doses absorbed by external irradiation for various types of radiation, the author gives figures for the comparative sensitivity of common detectors. He then defines the criteria which have to be considered for the choice of the sensitive medium and of the nature and the thickness of the detector walls. Considered very generally, the detection assembly intended for measuring the dose absorbed at a given point in the organism must be designed with a view to giving the same overall interactions with the radiation considered as those occurring in the organism. (author) [French] Apres avoir precise l'etat de nos connaissances generales actuelles concernant la determination des doses absorbees par irradiation externe pour les divers rayonnements, l'auteur indique la sensibilite comparee des detecteurs usuels. Il definit ensuite les criteres qui doivent etre pris en consideration pour le choix du milieu sensible, de la nature et de l'epaisseur de la paroi des detecteurs. D'une maniere tres generale, l'ensemble de detection destine a mesurer une dose absorbee en un point donne de l'organisme doit etre concu en vue de presenter les memes interactions globales avec le rayonnement etudie que celles mises en jeu dans l'organisme. (auteur)

  18. Partial radiative capture of resonance neutrons; Capture radiative partielle des neutrons de resonance

    Energy Technology Data Exchange (ETDEWEB)

    Samour, C. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    The radiative capture of resonance neutrons has been studied near the Saclay linac between 0.5 and 700 eV with time-of-flight method and a Ge(Li) detector. {sup 195}Pt + n and {sup 183}W + n allow the study of the distribution of partial radiative widths and their eventual correlation and also the variation of < {gamma}{sub {gamma}{sub i}} > with E{sub {gamma}}. The mean values of Ml and El transition intensities are compared in several tin isotopes. Interference effects, either between resonances or between direct capture and resonant capture are found in {sup 195}Pt + n, {sup 197}Au + n and {sup 59}Co + n. The excited level schemes of a great deal of nuclei are obtained and compared with theoretical predictions. This study has been completed by an analysis of thermal spectrum. (author) [French] La capture radiative des neutrons de resonance a ete etudiee pres de l'accelerateur lineaire de Saclay entre 0,5 et 700 eV a l'aide de la methode du temps-de-vol et d'un detecteur Ge(Li). Les noyaux {sup 195}Pt + n et {sup 183}W + n permettent l'analyse de la distribution de resonance en resonance des largeurs radiatives partielles {gamma}{sub {gamma}{sub i}} et de leur eventuelle correlation, ainsi que l'etude de la variation de < {gamma}{sub {gamma}{sub i}} > en fonction de E{sub {gamma}}. Les intensites moyennes des transitions Ml et El sont comparees pour quelques isotopes de l'etain. Des effets d'interference, soit entre resonances, soit entre capture directe et capture resonnante sont mis en evidence dans {sup 195}Pt + n, {sup 197}Au + n et {sup 59}Co + n. Enfin les schemas des etats excites d'un grand nombre de noyaux sont obtenus et compares avec les predictions theoriques. Cette etude a ete completee par une analyse des spectres thermiques. (auteur)

  19. Partial radiative capture of resonance neutrons; Capture radiative partielle des neutrons de resonance

    Energy Technology Data Exchange (ETDEWEB)

    Samour, C [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    The radiative capture of resonance neutrons has been studied near the Saclay linac between 0.5 and 700 eV with time-of-flight method and a Ge(Li) detector. {sup 195}Pt + n and {sup 183}W + n allow the study of the distribution of partial radiative widths and their eventual correlation and also the variation of < {gamma}{sub {gamma}{sub i}} > with E{sub {gamma}}. The mean values of Ml and El transition intensities are compared in several tin isotopes. Interference effects, either between resonances or between direct capture and resonant capture are found in {sup 195}Pt + n, {sup 197}Au + n and {sup 59}Co + n. The excited level schemes of a great deal of nuclei are obtained and compared with theoretical predictions. This study has been completed by an analysis of thermal spectrum. (author) [French] La capture radiative des neutrons de resonance a ete etudiee pres de l'accelerateur lineaire de Saclay entre 0,5 et 700 eV a l'aide de la methode du temps-de-vol et d'un detecteur Ge(Li). Les noyaux {sup 195}Pt + n et {sup 183}W + n permettent l'analyse de la distribution de resonance en resonance des largeurs radiatives partielles {gamma}{sub {gamma}{sub i}} et de leur eventuelle correlation, ainsi que l'etude de la variation de < {gamma}{sub {gamma}{sub i}} > en fonction de E{sub {gamma}}. Les intensites moyennes des transitions Ml et El sont comparees pour quelques isotopes de l'etain. Des effets d'interference, soit entre resonances, soit entre capture directe et capture resonnante sont mis en evidence dans {sup 195}Pt + n, {sup 197}Au + n et {sup 59}Co + n. Enfin les schemas des etats excites d'un grand nombre de noyaux sont obtenus et compares avec les predictions theoriques. Cette etude a ete completee par une analyse des spectres thermiques. (auteur)

  20. Behaviour of semiconductor nuclear-particle detectors; Comportement des semi-conducteurs comme detecteurs de particules nucleaires; Povedenie detektorov yadernykh chastits na poluprovodnikakh; Propiedades de los detectores de particulas nucleares a base de semiconductores

    Energy Technology Data Exchange (ETDEWEB)

    Walter, F J; Dabbs, J W.T.; Roberts, L D [Oak Ridge National Laboratory, Oak Ridge, TN (United States)

    1962-04-15

    . Matched expansion-coefficient fabrication techniques which have been successfully used to make detectors up to 8 cm{sup 2} in active area are also described. (author) [French] Les auteurs ont fait des etudes theoriques et experimentales sur le comportement des semi-conducteurs comme detecteurs de particules nucleaires a des temperatures allant de 0,2{sup o} K a 300{sup o} K. Ils presentent un modele theorique simple du comportement du detecteur qui correspond au comportement observe pour toute une gamme de valeurs des parametres. Ils examinent quelle est l'importance de la purete du semi-conducteur et de la tension de polarisation en ce qui concerne l'amplitude de l'impulsion, le temps de montee de l'impulsion et la surface du detecteur. Des etudes empiriques sur le bruit et la resolution en energie montrent que, pour des particules alpha, les plus petites largeurs de crete observees sont tres nettement plus importantes que les largeurs que l'on avait prevues en tenant compte du bruit d'origine electrique provenant du detecteur et de l'amplificateur. A 77{sup o}K, on a releve pour un detecteur a barriere de surface au silicium, d'une surface de 40 mm{sup 2}, des intensites de bruit equivalant a {<=} 3 keV (largeur totale a mi-hauteur du maximum). Les semi-conducteurs presentent un a l'egard des fragments de fission. On a tout lieu de penser que ce defaut n'est pas du a une . Si des champs electriques insuffisants pour assurer une complete sont la cause de ce defaut, le gradient de champ necessaire (a la surface) est superieur a 3 {center_dot} 10{sup 4} V/cm dans le cas de fragments de fission contre 2 {center_dot} 10{sup 3} V/cm dans le cas de particules alpha de Ge et de Si. Des etudes detaillees sur le temps de montee des impulsions au niveau de l'amplificateur ont montre que pour des substances de grande resistivite le temps de relaxation dielectrique et la resistance propres aux substances de base non appauvries peuvent

  1. Detection of high energy gamma radiations with liquid rare gases as scintillators; Detection des rayonnements Gamma de grande energie avec les gaz rares liquides comme scintillateurs

    Energy Technology Data Exchange (ETDEWEB)

    Ho, Phan Xuan

    1965-11-25

    This research thesis reports the study of a sensor based on a liquid scintillator for the detection of high energy (10 to 30 MeV) gamma radiations. The scintillator is a liquefied argon or xenon rare gas. The author first studies the process of energy transfer from the particle to the sensing medium. He addresses the different involved elements and phenomena: electromagnetic radiations (Compton Effect, photoelectric effect, pair production, and total gamma absorption), charged particles (braking radiation, collisions) and application to gamma spectrometry. He describes and discusses the scintillation mechanisms (scintillation of organic and inorganic materials), the general characteristics of scintillators (impurities, converters), and then reports the practical realisation of the sensor. Results are presented and discussed [French] Dans ce travail, nous nous proposons d'etudier une technique. Il s'agit d'un detecteur a scintillateur liquide pour la detection des rayonnements gamma energiques (10 a 30 MeV). Le scintillateur utilise est un gaz rare liquefie argon ou xenon. Nous examinerons d'abord les processus de transfert de l'energie de la particule au milieu detecteur puis les mecanismes de scintillation en general pour pouvoir exploiter au mieux les phenomenes favorables. Nous presenterons ensuite la realisation pratique du detecteur. Ses qualites (et defauts) trouveront leur place dans la fin de ce memoire. Bien qu'a l'heure actuelle, par la methode de Kyropoulos, on puisse faire pousser des gros cristaux d'iodure de sodium, l'utilisation des 'gaz rares' liquefies comme scintillateurs est, grace a la brievete de la scintillation, tres utile lorsqu'on recherche un fort taux de comptage (jusqu'a 10 impulsions par seconde) ou lorsqu'on veut resoudre certains problemes de coincidence. Les cristaux NaI(Tl) de grandes dimensions sont d'un montage facile mais leur manipulation requiert beaucoup de precautions du fait qu'ils supportent tres mal les chocs thermiques

  2. Some Applications of Surface Barrier Solid-State Detectors for Alpha-Activity Detection and Measurement; Quelques Applications des Detecteurs a Semi-Conducteurs a Barriere de Surface pour Deceler et Mesurer l'Activite Alpha; Nekotorye vidy primeneniya detektorov tverdogo sostoyaniya s poverkhnostnym bar'erom dlya izmereniya i obnaruzheniya al'fa-aktivnosti; Aplicaciones de los Detectores de Semiconductores de Barrera Superficial a la Deteccion y Medicion de Emisores Alfa

    Energy Technology Data Exchange (ETDEWEB)

    Perry, K. E.G. [Atomic Energy Establishment, Winfrith, Dorset (United Kingdom)

    1965-10-15

    -state detector and the output taken to a multichannel analyser. Details of these equipments and the results obtained are presented. A new design of automatic alpha-assay equipment, including a solid-state detector, is employed for monitoring the filter papers taken from personnel air samplers that have been worn by personnel employed in handling plutonium. This equipment automatically counts each of 12 filter papers for a pre-determined period and prints out the total counts recorded. It also incorporates a sequential analysis circuit which gives a very rapid decision as to whether the sample is above or below a pre-set level. The same technique could easily be applied to a wide range of sample assay measurements. Considerable use is also being made of solid-state detectors in various types of probe for general alpha monitoring; probes have been designed with sensitive areas ranging from 12-18 cm{sup 2}. Small area detectors are useful for locating spots of contamination on the surface of the body, where their robustness, lack of light sensitivity and the simplicity of the associated equipment make them more attractive than the other types of detectors (e.g. scintillators) for this purpose. An important further attractive feature of the solid-state detector is lack of response (compared to the normal ZnS scintillation counter) to gamma-radiation; this is important when monitoring for alpha contamination in the presence of a high gamma background, e.g. detecting leakage material from a radium needle or radon seed. Details of these probes are given. (author) [French] Les detecteurs a semi-conducteurs sont de plus en plus utilises dans les etablissements de l'Autorite de l'energie atomique du Royaume-Uni pour les mesures d'echantillons biologiques et les controles de radioprotection. La methode la plus frequemment employee pour evaluer la quantite de plutonium fixee dans l'organisme du personnel expose consiste a prelever des echantillons d'urine et de matieres fecales. Ces

  3. Mesure de la Polarisation des Lambda Produits dans les Collisions Positron-Electron AU Lep a L'aide du Detecteur Opal

    Science.gov (United States)

    Vandenplas, Denis

    Le Modele Standard est le cadre theorique general qui, jusqu'a present, a permis l'interpretation de tous les resultats experimentaux en physique des hautes energies. Cette theorie decrit, entre autres, la production d'une paire de particules elementaires, formee d'un quark et d'un antiquark, a partir de la desintegration de l'un des bosons mediateurs de l'interaction faible, le Z^0. Cependant, dans ce cas precis, la transformation subsequente des quarks primaires en particules reelles, un processus appele hadronisation, n'est decrite qu'a l'aide de modeles phenomenologiques. Afin de sonder les mecanismes de l'hadronisation, cette these presente la mesure du transfert du spin d'un quark etrange primaire a une particule appelee Lambda lors des desintegrations hadroniques du Z^0. L'etude a ete realisee dans le cadre de la collaboration OPAL, une des quatre experiences menees au collisionneur LEP, la ou des electrons et des positrons sont acceleres jusqu'a une energie commune, sqrt{s} = {rm E_ {cm}}, voisine de l'energie de production du rm Z^0, M_{Z ^0} egale a 91.3 GeV. La theorie electrofaible precise la direction du spin, c'est-a-dire la polarisation, d'un quark etrange primaire provenant de la desintegration d'un Z ^0. Quant a lui, le modele des quarks etablit que l'orientation du spin d'un Lambda est directement reliee a la polarisation du quark etrange dont il provient. La question est de determiner dans quelle mesure la polarisation du quark primaire est transmise au Lambda a la suite du processus de l'hadronisation, decrit dans le cadre de la ChromoDynamique Quantique. Une estimation, qui tient compte de tous ces differents aspects theoriques, evalue a 30% la polarisation des Lambda dont l'impulsion est superieure a 15 GeV/c. La mesure experimentale de la polarisation repose sur l'identification des Lambda a partir de la reconstitution de la desintegration Lambdato ppi^-. Ce processus, qui se deroule par le biais de l'interaction faible, viole la parite car

  4. Control panel for radiation around reactors (1963); Tableaux de controle des radiations aupres des piles (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Candes, P; Barthoux, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    This report outlines the general philosophy of radiation control in French reactors and their annexes. The supervision is carried out continuously from a central control panel on which appear all the measurements made and the alarm signals. The equipment is described; one item makes it possible to measure simultaneously the radioactive dusts and gases. The specifications of the alarm system, which is considered to be the most important are given. Finally a new measuring technique is proposed which makes it possible to reduce considerably the cost of radiation control while at the same time providing the results in a form in which they can be easily treated, in particular in the case of the calculation of total doses. (authors) [French] Ce rapport definit la philosophie generale du controle des radiations dans les piles francaises et dans leurs annexes. La surveillance se fait d'une maniere continue a partir d'un tableau de controle centralise ou sont reportees toutes les mesures et les signalisations d'alarme. On decrit les appareils utilises, dont un permet la mesure simultanee des poussieres et gaz radioactifs, et on definit les specifications de la fonction alarme qui est consideree comme la plus importante. Enfin on propose une nouvelle technique de mesure qui permettrait de reduire considerablement le cout du controle des radiations tout en fournissant des resultats plus facilement exploitables, en particulier pour le calcul des doses integrees. (auteurs)

  5. Effects of radiation; Effets des radiations

    Energy Technology Data Exchange (ETDEWEB)

    Masse, R [Office de Protection contre les Rayonnements Ionisants, 78 - le Vesinet (France)

    2006-07-01

    The medical consequences of a whole-body irradiation come from the destruction of cells and inflammatory reactions it provokes. The most sensitive organs are the tissues that actively split. The embryo is particularly sensitive, from 200 mSv for the effects on the brain development. The reproduction functions are reached for man from 2000 mSv, the ovary sensitivity is less, the oocytes do not split after the fetus life. For adult the bone marrow outrage leads to the disappearing of blood cells (4000 mSv). The doses from 6000 to 10000 mSv lead the failure of the digestive system and lung. for the upper doses every tissue is reached, particularly by the effects on cells of blood vessels. Important brain dysfunctions appear beyond 10000 mSv. As regards the delayed effects of overexposures the epidemiology brings to light sanitary consequences of the exposure of the population to the ionizing radiations and requires that all the possible factors associated for that purpose are considered. About hereditary effects, it appears that moderate acute radiation exposures of even a relatively large human population must have little impact, in spite of the rate of spontaneous congenital deformations is of the order of 6 %. For the induction of cancers, it is not observed excess for doses lower than 200 mSv for adults and 100 mSv for children (the populations studied are survival people of hiroshima and Nagasaki, patients treated by irradiation, uranium miners, children exposed to radioactive iodine after Chernobylsk accident). To simplify an expression of the risk has been fixed to 5% of induced cancer by Sv for population and 4% by Sv for workers, the different being explained by the demography and the sensitivity of the youngest age groups. As regards the low doses of radiations, a bundle of convergent epidemiological observations notices the absence of effects of the low doses rates. Biological mechanisms, notably of repair are approached, then certain accidents (Goiania

  6. Effects of radiation; Effets des radiations

    Energy Technology Data Exchange (ETDEWEB)

    Masse, R. [Office de Protection contre les Rayonnements Ionisants, 78 - le Vesinet (France)

    2006-07-01

    The medical consequences of a whole-body irradiation come from the destruction of cells and inflammatory reactions it provokes. The most sensitive organs are the tissues that actively split. The embryo is particularly sensitive, from 200 mSv for the effects on the brain development. The reproduction functions are reached for man from 2000 mSv, the ovary sensitivity is less, the oocytes do not split after the fetus life. For adult the bone marrow outrage leads to the disappearing of blood cells (4000 mSv). The doses from 6000 to 10000 mSv lead the failure of the digestive system and lung. for the upper doses every tissue is reached, particularly by the effects on cells of blood vessels. Important brain dysfunctions appear beyond 10000 mSv. As regards the delayed effects of overexposures the epidemiology brings to light sanitary consequences of the exposure of the population to the ionizing radiations and requires that all the possible factors associated for that purpose are considered. About hereditary effects, it appears that moderate acute radiation exposures of even a relatively large human population must have little impact, in spite of the rate of spontaneous congenital deformations is of the order of 6 %. For the induction of cancers, it is not observed excess for doses lower than 200 mSv for adults and 100 mSv for children (the populations studied are survival people of hiroshima and Nagasaki, patients treated by irradiation, uranium miners, children exposed to radioactive iodine after Chernobylsk accident). To simplify an expression of the risk has been fixed to 5% of induced cancer by Sv for population and 4% by Sv for workers, the different being explained by the demography and the sensitivity of the youngest age groups. As regards the low doses of radiations, a bundle of convergent epidemiological observations notices the absence of effects of the low doses rates. Biological mechanisms, notably of repair are approached, then certain accidents (Goiania

  7. Electrical limitations to energy resolution in semiconductor particle detectors; Limitations electriques du pouvoir de resolution en energie des detecteurs a semi-conducteurs; Ehlektricheskie ogranicheniya razreshayushchej sposobnosti po ehnergii v poluprovodnikovykh detektorakh chastits; Limitaciones electricas en la resolucion energetica de detectores de particulas a base de semiconductores

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, W L; Goulding, F S [Lawrence Radiation Laboratory, University of California, Berkeley, CA (United States)

    1962-04-15

    Based on the assumption that the noise contribution of a semiconductor detector is due solely to its bulk properties, equations are presented which indicate the theoretical limits of noise in detectoramplifier combinations. These equations show that an optimum amplifier time-constant and detector bias voltage exist for which condition the minimum noise is independent of the semiconductor resistivity. The optimum performance of a detector-amplifier system is shown to depend only upon detector area, input capacity (less detector capacity), semiconductor minority carrier lifetime and the transconductance of the amplifier input tube. A new detector structure which includes a guard-ring electrode as an integral part of the detector structure is described which has the effect of largely eliminating noise due to surface leakage. Experimental results for detector leakage and energy resolution which agree well with theory are presented. The theoretical limit of noise, expressed as full width at half maximum, is from 7 to 10 keV for 1-cm{sup 2} p-type silicon detectors at 25{sup o}C. (author) [French] Partant de l'hypothese que le bruit imputable au detecteur a semi-conducteur est du exclusivement aux proprietes fondamentales du semi-conducteur, les auteurs etablissent des equations donnant les limites theoriques du bruit dans les combinaisons detecteur-amplificateur. Ces equations montrent qu'il existe une constante de temps optimum de l'amplificateur et une tension de polarisation du detecteur, pour lesquelles le bruit minimum est independant de la resistivite du semi-conducteur. Les auteurs prouvent que l'optimum de fonctionnement d'un ensemble detecteur-amplificateur ne depend que de la surface du detecteur, de la capacite a l'entree (deduction faite de la capacite du detecteur), du porteur minoritaire du semi-conducteur, de la duree de vie et de la transconductance du tube d'entree de l'amplificateur. Ils decrivent un modele nouveau de detecteur qui comprend une

  8. Fast neutron dosimetry and spectrometry using radioactivation (1963); Dosimetrie et spectrometrie des neutrons rapides par radioactivation (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Lamberieux, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-07-01

    The author first recalls rapidly a few generalities concerning induced radioactivity detectors and gives, in an appendix, tables summarizing the properties of detector elements which may be used in radioprotection. The excitation functions found in the literature and also given. The technological characteristics of the detectors used are given, together with the counting methods. The many advantages of activation dosimetry for strong or periodic neutron fluxes and for those in the presence of {gamma}-radiation are stressed. The main problem in activation dosimetry is, however, the calculation of the dose absorbed from the results of the measurements. It is shown how the dose is expressed, fairly accurately, as a function of the radioactivities induced in a series of detectors. As an example, the spectrometry and the dosimetry of the neutron flux emitted by a Po-Be source are presented. (author) [French] L'auteur fait d'abord un bref rappel des generalites sur les detecteurs a radioactivite induite, accompagne, en annexe, des tableaux resumant les proprietes d'elements detecteurs utilisables en radioprotection. Les fonctions d'excitation trouvees dans la litterature y sont egalement annexees. On donne ensuite les caracteristiques technologiques des detecteurs employes ainsi que les methodes de comptage utilisees. On souligne les nombreux avantages de la dosimetrie par activation dans les flux de neutrons intenses ou periodiques et en presence de rayonnement {gamma}. Il reste que le probleme central de la dosimetrie par activation est le calcul de la dose absorbee a partir des resultats de mesure. On montre comment la dose s'exprime, de maniere approchee, en fonction des radioactivites induites dans une serie de detecteurs. A titre d'exemple, la spectrometrie et la dosimetrie du flux de neutrons emis par une source de Po-Be sont presentees. (auteur)

  9. Coincidence measurements with the use of detectors measuring the energy of the radiances (proportional meters and scintillation counter); Mesures de coincidences avec utilisation de detecteurs mesurant l'energie des rayonnements (compteurs proportionnels et compteur a scintillations)

    Energy Technology Data Exchange (ETDEWEB)

    Sartory, M [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires

    1953-07-01

    In the setting of the realization of a set of installations permitting of the measures of coincidences between sorted radiances according to their energies, an installation understanding a proportional counter and a scintillation counter has been constructed and optimized. It has been used to do some measures of coincidences between X{sub K} photons and photons {gamma} issued at the time of the radioactive transformation of the selenium 75 (electronic capture). The efficiency of the proportional meter has been determined roughly. Besides, a proportional counter of solid angle neighboring of 4{pi} was able to achieve measures of coincidences while only doing one selection of amplitudes: indeed, the simultaneity of the detection of two radiances appear by an impulse whose amplitude is the sum of the amplitudes of the impulses resulting from each of the studied radiations. This method, applied to the coincidences between X-rays, permitted to bring the information on the diagram of decay of the arsenic 73. Besides, the coefficient of internal conversion of a consecutive transition to this decay has been valued. (author) [French] Dans le cadre de la realisation d'une serie de montages permettant des mesures de coincidences entre rayonnements tries d'apres leurs energies, un montage comprenant un compteur proportionnel et un compteur a scintillations a ete construit et mis au point. Il a ete utilise pour effectuer quelques mesures de coincidences entre photons X{sub K} et photons {gamma} emis lors de la transformation radioactive du selenium 75 (capture electronique). L'efficacite du compteur proportionnel a ete approximativement determinee. De plus, un compteur proportionnel d'angle solide voisin de 4{pi} a pu etre utilise pour realiser des mesures de coincidences en n'effectuant qu'une selection d'amplitudes: en effet, la simultaneite de la detection de deux rayonnements se manifeste par une impulsion dont l'amplitude est la somme des amplitudes des impulsions

  10. Detectors - Electronics; Detecteurs - Electronique

    Energy Technology Data Exchange (ETDEWEB)

    Bregeault, J.; Gabriel, J.L.; Hierle, G.; Lebotlan, P.; Leconte, A.; Lelandais, J.; Mosrin, P.; Munsch, P.; Saur, H.; Tillier, J. [Lab. de Physique Corpusculaire, Caen Univ., 14 (France)

    1998-04-01

    The reports presents the main results obtained in the fields of radiation detectors and associated electronics. In the domain of X-ray gas detectors for the keV range efforts were undertaken to rise the detector efficiency. Multiple gap parallel plate chambers of different types as well as different types of X {yields} e{sup -} converters were tested to improve the efficiency (values of 2.4% at 60 KeV were reached). In the field of scintillators a study of new crystals has been carried out (among which Lutetium orthosilicate). CdTe diode strips for obtaining X-ray imaging were studied. The complete study of a linear array of 8 CdTe pixels has been performed and certified. The results are encouraging and point to this method as a satisfying solution. Also, a large dimension programmable chamber was used to study the influence of temperature on the inorganic scintillators in an interval from -40 deg. C to +150 deg. C. Temperature effects on other detectors and electronic circuits were also investigated. In the report mentioned is also the work carried out for the realization of the DEMON neutron multidetector. For neutron halo experiments different large area Si detectors associated with solid and gas position detectors were realized. In the frame of a contract with COGEMA a systematic study of Li doped glasses was undertaken aiming at replacing with a neutron probe the {sup 3}He counters presently utilized in pollution monitoring. An industrial prototype has been realised. Other studies were related to integrated analog chains, materials for Cherenkov detectors, scintillation probes for experiments on fundamental processes, gas position sensitive detectors, etc. In the field of associated electronics there are mentioned the works related to the multidetector INDRA, data acquisition, software gamma spectrometry, automatic gas pressure regulation in detectors, etc

  11. Neutron Dosimetry and Irradiation of Solids; Dosimetrie des neutrons et irradiation des solides

    Energy Technology Data Exchange (ETDEWEB)

    Perriot, G; Schmitt, A P [Commissariat a l' Energie Atomique. Centre d' Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France)

    1962-07-01

    Results of work at C.E.A. from 1958 to 1960 are reviewed. The possibilities offered by classical dosimetry methods are discussed. The tests which led to the utilization, for fast neutron dosimetry, of resistivity variations induced in solid W by such neutrons are described. Experimental W irradiation results led to a definition of neutron efficiency which describes the relations between neutron energy and their effects on materials. Possibilities offered by detectors which make use of radiation damage and are sensitive to neutrons at keV energies were explored. In other work, the principal French reactors were classified according to their ability to produce damage in materials such as W. (authors) [French] Dans ce rapport on a presente les resultats essentiels de travaux qui ont ete effectues de 1958 a 1980 par des chercheurs du CEA issus de differents services. En meme temps qu'une revue des possibilites offertes a l'epoque par les methodes classiques de dosimetrie (utilisation des detecteurs par activation), on a decrit les essais qui devaient permettre d'utiliser, a la dosimetrie les neutrons rapides, les variations de resistivite qu'ils creent dans un corps solide (tungstene). L'irradiation du tungstene a montre l'importance qu'il y avait a definir 'l'efficacite' des neutrons, c'est-a-dire leur aptitude plus ou moins grande, selon leur energie, a creer des defauts dans les materiaux. L'efficacite d'un emplacement d'irradiation se trouvant liee au spectre neutronique, on a vu les difficultes qu'il y avait a utiliser les detecteurs par activation des qu'on n'avait plus affaire a un spectre en 1/E ou de fission et on a pu entrevoir les possibilites offertes par les detecteurs utilisant la creation des defauts qui repondent a tous les neutrons d'energies, superieures a quelques keV. Enfin, on a classe les principaux types de Piles Francaises selon leur aptitude a creer plus ou moins rapidement des dommages dans des materiaux comme le tungstene. (auteur)

  12. Study of catalytic phenomena in radiation chemistry; Etude des phenomenes catalytiques en chimie des radiations

    Energy Technology Data Exchange (ETDEWEB)

    Dran, J C [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-01-01

    Two phenomena have been studied: the action of {gamma} rays from radio-cobalt on the adsorption and catalytic properties of ZnO and NiO in. relationship with the heterogeneous oxidation of CO, and the homogeneous catalysis by OsO{sub 4} of the oxidation of various aqueous phase solutes by the same radiation. The prior irradiation of ZnO and of NiO does not modify their catalytic activity but generally increases the adsorption energy of -the gases CO and O{sub 2}. The influence of the radiations appears to be connected with the presence of traces of water on ZnO and of an excess of oxygen on NiO. Osmium tetroxide which is not degraded by irradiation in acid solution, accelerates the radiolytic oxidation of certain compounds (Te{sup IV}, Pt{sup 11}, As{sup 111}) in the presence of oxygen, as a result of its sensitizing effect on the oxidation by H{sub 2}O{sub 2}. In the case of phosphites on the other hand, OsO{sub 4} has a protecting action under certain conditions of acidity and may suppress entirely the chain reaction which characterizes the oxidation of this solute by{gamma} rays. A general mechanism is proposed for these phenomena. The rate constant for the OsO{sub 4} + HO{sub 2} reaction is calculated to be 5.7 x 10{sup 5} l.mol{sup -1}. sec{sup -1}. (author) [French] Deux phenomenes ont ete etudies: l'action des rayons {gamma} du radio-cobalt sur les proprietes adsorptives et catalytiques de ZnO et NiO en relation avec l'oxydation heterogene de CO et la catalyse homogene par OsO{sub 4} de l'oxydation de divers solutes en phase aqueuse par ce meme rayonnement. L'irradiation prealable de ZnO et de NiO n'a pas modifie leur activite catalytique, mais a generalement accru l'energie d'adsorption des gaz CO et O{sub 2}. L'influence des radiations semble liee a la presence de traces d'eau sur ZnO et d'un exces d'oxygene sur NiO. Le tetroxyde d'osmium qui n'est pas altere par le rayonnement en solution acide, accelere l'oxydation radiolytique de certains composes. (Te

  13. Study of catalytic phenomena in radiation chemistry; Etude des phenomenes catalytiques en chimie des radiations

    Energy Technology Data Exchange (ETDEWEB)

    Dran, J.C. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-01-01

    Two phenomena have been studied: the action of {gamma} rays from radio-cobalt on the adsorption and catalytic properties of ZnO and NiO in. relationship with the heterogeneous oxidation of CO, and the homogeneous catalysis by OsO{sub 4} of the oxidation of various aqueous phase solutes by the same radiation. The prior irradiation of ZnO and of NiO does not modify their catalytic activity but generally increases the adsorption energy of -the gases CO and O{sub 2}. The influence of the radiations appears to be connected with the presence of traces of water on ZnO and of an excess of oxygen on NiO. Osmium tetroxide which is not degraded by irradiation in acid solution, accelerates the radiolytic oxidation of certain compounds (Te{sup IV}, Pt{sup 11}, As{sup 111}) in the presence of oxygen, as a result of its sensitizing effect on the oxidation by H{sub 2}O{sub 2}. In the case of phosphites on the other hand, OsO{sub 4} has a protecting action under certain conditions of acidity and may suppress entirely the chain reaction which characterizes the oxidation of this solute by{gamma} rays. A general mechanism is proposed for these phenomena. The rate constant for the OsO{sub 4} + HO{sub 2} reaction is calculated to be 5.7 x 10{sup 5} l.mol{sup -1}. sec{sup -1}. (author) [French] Deux phenomenes ont ete etudies: l'action des rayons {gamma} du radio-cobalt sur les proprietes adsorptives et catalytiques de ZnO et NiO en relation avec l'oxydation heterogene de CO et la catalyse homogene par OsO{sub 4} de l'oxydation de divers solutes en phase aqueuse par ce meme rayonnement. L'irradiation prealable de ZnO et de NiO n'a pas modifie leur activite catalytique, mais a generalement accru l'energie d'adsorption des gaz CO et O{sub 2}. L'influence des radiations semble liee a la presence de traces d'eau sur ZnO et d'un exces d'oxygene sur NiO. Le tetroxyde d'osmium qui n'est pas altere par le rayonnement en solution

  14. Radiation hazards in the neighbourhood of uranium reactors; Dangers des rayonnements aupres des piles a uranium

    Energy Technology Data Exchange (ETDEWEB)

    Joffre, H [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1956-07-01

    Radiation hazards near uranium reactors may be divided in two groups. Hazards when the reactor is normally operating: {gamma} radiation from hot uranium or air contamination by fission gases, {gamma} radiation or contamination by the coolant (air, nitrogen, heavy-water), {gamma} radiation from radioisotopes. Hazards in the case of an accident: presence of hot uranium in the atmosphere, soil contamination. (author) [French] Les dangers d'irradiation aupres des piles a uranium sont a classer essentiellement en deux groupes. Les dangers existant aupres d'une pile exploitee normalement: irradiation {gamma} par l'uranium irradie ou contamination de l'air par des gaz de fission, irradiation {gamma} ou contamination par les fluides de refroidissement (air, azote, eau lourde), irradiation {gamma} par les radioelements fabriques. Les dangers en cas d'accident survenant a un reacteur en fonctionnement, ayant pour consequence : la presence dans l'air d'uranium irradie, la contamination du sol. (auteur)

  15. Calibration of a leak detection spectrometer; Calibration d'un spectrometre detecteur de fuites

    Energy Technology Data Exchange (ETDEWEB)

    Geller, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    This paper describes a study of the possible methods for calibrating a leak detection spectrometer, and the estimation of outputs from the leaks is considered. With this in mind the question of sensitivity of leak detection is tackled on a very general level; first the sensitivity of the isolated instrument is determined, and then the sensitivity of an instrument connected to an installation where leaks may be suspected. Finally, practical solutions are proposed. (author) [French] Dans cet article, nous etudions les methodes possibles de calibration d'un spectrometre detecteur de fuites et nous envisageons l'evaluation des debits de fuites trouves. Pour cela, nous abordons la notion de sensibilite de la detection de fuite sur un plan tres general; d'abord nous determinons la sensibilite de l'appareil isole, ensuite la sensibilite d'un appareil connecte sur une installation ou l'on cherche les fuites. Enfin, nous preconisons des solutions pratiques. (auteur)

  16. A spectrometer using semi-conductor detectors; study and applications (1963); Spectrometre utilisant les detecteurs a semi-conducteur: etudes et applications (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Roux, G [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-07-01

    The low average energy, 2.5 to 3.5 eV, required to produce one hole-electron pair in a semiconductor allows an accurate measurement of the energy of the ionizing particles. A high resolution spectrometer has been built using semiconductor detectors. The limit of resolution, due to electronics associated to the detector, to the detector itself and to the source of particles is studied here. The present practical limit of resolution of the spectrometer is 1700 elementary electric charges (full width at half maximum of a ray of a spectrum) or 6 keV in terms of energy lost by a particle in a silicon detector. The physical resolution usually obtained is 20 keV (0.33 per cent) with {alpha} particles of the {sup 212}Bi (6.087 MeV). It depends a lot of the kind of detector used. Some results, concerning the background of the detectors and limit of measurements for low energies are given. Various applications are presented: spectrometry {beta}, spectrometry {gamma} and X, spectrometry of mixtures of {alpha} radioactive elements, collection of {alpha} spectra. (author) [French] La faible energie moyenne, 2,5 a 3,5 eV, necessaire pour produire une paire electron-trou dans un semi-conducteur, permet une mesure precise de l'energie des particules ionisantes. Un spectrometre a haute resolution a ete construit utilisant des detecteurs a semi-conducteur. La limitation en resolution due a l'electronique associee au detecteur, au detecteur lui-meme et a la source de particules, est etudiee. La resolution pratique limite actuelle du spectrometre est 1700 charges electriques elementaires (largeur a mi-hauteur d'une raie de spectre) ou 6 keV exprimee en energie perdue par une particule dans un detecteur au silicium. La resolution physique couramment obtenue est de 20 keV (0,33 pour cent) pour les particules {alpha} du bismuth 212 (6,087 MeV). Elle depend beaucoup du detecteur utilise. Quelques resultats sont donnes concernant le mouvement propre des detecteurs et la limitation des

  17. The leakage problem in vacuum system. Realization of a mass spectrometer detecting leaks; Le probleme des fuites en technique du vide. Realisation d'un spectrometre de masse detecteur de fuite

    Energy Technology Data Exchange (ETDEWEB)

    Geller, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1954-11-15

    In the first part of this paper we consider the problem of leaks in vacuum systems, and their detection. We consider in particular the method of detection by means of a helium spectrometer. The second part deals with the experimental set p. The analyser and the ion source have been studied in great detail, and we have also discussed the technological and mechanical aspects of the apparatus and its performances. (author) [French] Dans la premiere partie de ce travail, nous traitons le probleme des fuites en technique du vide et leur detection en general. La methode de detection par spectrometre a helium y est envisagee plus particulierement. La deuxieme partie de l'article est consacree a la realisation du spectrometre. Le tube analyseur et la source d'ions y sont etudies en detail. Nous exposons de meme les conceptions technologiques et mecaniques de l'appareil ainsi que ses performances. (auteur)

  18. Decontamination of plutonium-contaminated surfaces; Essais de decontamination des surfaces contaminees par du plutonium

    Energy Technology Data Exchange (ETDEWEB)

    Bertrand, J; Clouet d' Orval, Ch; Tachon, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    The measure of the neutron distribution in the core of 'Proserpine', by means of activation detectors, requires no contact between the plutonium sulfate solution and the detectors. These detectors are put into PVC or polyethylene bags. This report describes the process used to decontaminate these bags. A washing by nitric acid followed by coating with plexiglass is kept, with this process we have no contamination on the detectors. (author) [French] La mesure de la distribution de neutrons par detecteurs a activation dans le coeur de Proserpine exige de proteger ces detecteurs contre tout contact avec la solution de plutonium. Les detecteurs sont places dans des gaines en polyvinyle ou en polyethylene. Ce rapport decrit le procede utilise pour decontaminer ces gaines. On a retenu un lavage a l'acide nitrique suivi du revetement d'une meme couche de plexiglass, ce qui permet d'eviter la contamination des detecteurs. (auteur)

  19. Detection of hard {beta} radiation in water using the Cerenkov effect; Detection des {beta} durs dans l'eau par effet Cerenkov

    Energy Technology Data Exchange (ETDEWEB)

    Turck, B [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-01-01

    The light emitted from a liquid during the passage of a particle of sufficiently high energy can be used to determine the contamination of water by {beta}-emitters. The detector based on this principle requires no special treatment of the water. Particular attention has been paid to the optical yield of the detector. However the excellent sensitivity to which this principle leads can only be attained if the background noise is considerably reduced. The electronics associated with detector make it possible to detect a contamination of 8 x 10{sup -8} {mu}c/cm{sup 3} of strontium-90 in water in about ten minutes. The apparatus presents the double advantage of having a high sensitivity and of being easy to use. Its characteristics make it possible for it to be used for the continuous control of water. (author) [French] La lumiere emise au sein d'un liquide au passage d'une particule suffisamment energetique peut permettre de determiner la contamination d'une eau en emetteurs {beta}. Le detecteur realise sur ce principe ne necessite aucun traitement special de l'eau. Un soin tout particulier a ete apporte a l'etude du rendement optique du detecteur. Cependant l'excellente sensibilite attachee au principe ne peut etre utilisee que si l'on reduit considerablement le bruit de fond. L'electronique associee au detecteur permet de reperer l'existence d'une contamination de 8 x 10{sup -8} {mu}c/cm{sup 3} de strontium-90 dans l'eau en un temps d'une dizaine de minutes. L'appareil presente l'avantage d'allier une grande sensibilite a la facilite d'emploi. Ses performances autorisent son utilisation au controle continu des eaux. (auteur)

  20. Gas-flow detector for uranium contamination on finned-can surface of a reactor fuel; Detecteur a courant gazeux pour deceler la contamination en uranium des nervures des gaines de combustible nucleaire; Gazopotochnyj detektor zagryazneniya uranom rebristoj poverkhnosti obolochki reaktornykh teplovydelyayushchikh ehlementov; Detector de flujo gaseoso para medir la contaminacion de uranio en la superficie de la vaina de aletas de los elementos combustibles para reactores

    Energy Technology Data Exchange (ETDEWEB)

    Miwa, H; Shiojiri, T; Maeda, Y [Kobe Kogyo Corporation, Okubo, Akashi, Hyogo (Japan)

    1962-04-15

    Calder Hall-type reactor-fuel and all JRR-3 fuels are to be inspected by this counter. (author) [French] Le detecteur a courant gazeux presente par les auteurs est un compteur proportionnel a grille, specialement concu pour deceler la contamination en uranium des nervures des gaines de combustible nucleaire. Un compteur proportionnel classique, compose seulement d'une cathode et d'un collecteur, n'est guere capable de deceler les particules alpha emises par l'uranium contaminant une surface rugueuse telle que les nervures d'une gaine de combustible nucleaire, par suite du manque d'uniformite du champ electrique pres de la surface. C'est pourquoi les auteurs ont construit un compteur proportionnel a grille. Cet appareil, de forme cylindrique, comprend le combustible, une grille, des collecteurs et une cathode, tous les elements etant disposes suivant le meme axe. Le combustible est place au centre de la grille a laquelle on applique une tension negative. L'espace entre le combustible et la grille sert de collecteur d'ions. La grille, faite de fils paralleles minces en tungstene, disposes suivant un cylindre autour du combustible, est reliee a la terre. Les collecteurs sont constitues de 16 minces fils de tungstene disposes de la meme maniere que la grille, mais chaque fil est isole electriquement des autres. Tous les collecteurs sont interconnectes par des resistances de 5 x 10{sup 4} ohms et relies au positif de la haute tension par une resistance. L'espace entre la grille, les collecteurs et la cathode sert a la multiplication du gaz, tout comme dans un compteur proportionnel classique. Chaque resistance de 5 x 10{sup 4} ohms isole la capacite parasite de chaque collecteur. La sortie du detecteur est couplee a un amplificateur a faible impedance d'entree. La faible impedance d'entree diminue aussi l'influence facheuse de la capacite parasite du circuit d'entree. Il en resulte un rapport favorable signal/bruit de fond, ce qui permet une bonne detection des particules

  1. Study of the fluctuations of the partial and total radiative widths by neutron capture resonance method; Etude des fluctuations des largeurs radiatives partielles et totales par la capture des neutrons de resonance

    Energy Technology Data Exchange (ETDEWEB)

    Huynh, V D [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-06-01

    Radiative capture experiments by neutron time-of-flight methods have been made for following studies: distribution of partial radiative widths, effects of correlation between different radiative transitions, fluctuations of total radiative widths {gamma}{sub {gamma}} from resonance to resonance, variation of {gamma}{sub {gamma}} with number of mass and the search for the existence of potential capture. Also, some other experiments with the use of neutron capture gamma-rays spectra have been investigated. (author) [French] Par la capture des neutrons de resonance dont les energies sont selectionnees a l'aide de la technique du temps de vol, differents types d'experiences ont ete realisees concernant les etudes des distributions des largeurs radiatives partielles, des effets de correlation entre differentes voies de desexcitation, de la fluctuation des largeurs radiatives totales {gamma}{sub {gamma}} de resonance a resonance, de la variation de la quantite {gamma}{sub {gamma}} en fonction du nombre de masse et de la mise en evidence de l'existence du processus de capture potentielle. Quelques autres applications de l'emploi du spectre de rayons gamma ont egalement ete presentees. (auteur)

  2. Study of the fluctuations of the partial and total radiative widths by neutron capture resonance method; Etude des fluctuations des largeurs radiatives partielles et totales par la capture des neutrons de resonance

    Energy Technology Data Exchange (ETDEWEB)

    Huynh, V.D. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-06-01

    Radiative capture experiments by neutron time-of-flight methods have been made for following studies: distribution of partial radiative widths, effects of correlation between different radiative transitions, fluctuations of total radiative widths {gamma}{sub {gamma}} from resonance to resonance, variation of {gamma}{sub {gamma}} with number of mass and the search for the existence of potential capture. Also, some other experiments with the use of neutron capture gamma-rays spectra have been investigated. (author) [French] Par la capture des neutrons de resonance dont les energies sont selectionnees a l'aide de la technique du temps de vol, differents types d'experiences ont ete realisees concernant les etudes des distributions des largeurs radiatives partielles, des effets de correlation entre differentes voies de desexcitation, de la fluctuation des largeurs radiatives totales {gamma}{sub {gamma}} de resonance a resonance, de la variation de la quantite {gamma}{sub {gamma}} en fonction du nombre de masse et de la mise en evidence de l'existence du processus de capture potentielle. Quelques autres applications de l'emploi du spectre de rayons gamma ont egalement ete presentees. (auteur)

  3. Results obtained in a spectrometry using junction detectors (1962); Resultats en spectrometrie {alpha} a l'aide de ''detecteurs jonction'' (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Beaumevieille, H; Fontenille, J; Lottgequeue, J P; Longequeue, N; Rabour, C [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1962-07-01

    Junction detectors have been used for studying {alpha} spectra obtained by nuclear reactions (p, {alpha}), the protons being produced by an electrostatic accelerator (E{sub p} varying from 100 to 600 keV). Difficulties have been encountered arising from parasitic noise from the accelerator and from the distance (60 metres) between detectors and electronic equipment. Resolution of the counter has been found to be 0.6 per cent with {alpha} from {sup 210}Po and 1.2 pour cent with {alpha} (5.8 MeV) from the reaction {sup 11}B (p, {alpha}{sub 0}). (authors) [French] Des detecteurs a jonction ont ete utilises pour l'etude de spectres {alpha} obtenus par reactions nucleaires (p, {alpha}), les protons etant acceleres par un accelerateur electrostatique (E{sub p} variant de 100 a 600 keV). Des difficultes ont ete recontrees dues aux parasites provenant de l'accelerateur et a la distance des cables (60 metres) entre detecteurs et appareils de mesure. Le pouvoir de resolution de l'ensemble a ete de 0, 6 pour cent avec les {alpha} du {sup 210}Po et de 1,2 pour cent avec les {alpha} (5,8 MeV) de la reaction {sup 11}B (p, {alpha}{sub 0}). (auteurs)

  4. Resonance absorption of nuclear gamma radiation; Absorption par resonance des rayons gamma; Rezonansnaya absorbtsiya i rasseyanie yadernogo gamma-izlucheniya; Absorcion por resonancia de las radiaciones gamma en los nucleos

    Energy Technology Data Exchange (ETDEWEB)

    Hanna, S S; Perlow, G J [Argonne National Laboratory, Argonne, IL (United States)

    1962-01-15

    Recoilless emission and absorption of nuclear radiation, as demonstrated by Moessbauer, provides a simple means of studying the interaction of nuclei with electromagnetic radiation and, of greater importance, provides an extremely sensitive tool for the investigation of a large number of physical problems. A very favourable situation arises with the Fe{sup 57} nucleus where resonance absorption may be used as a very sensitive detector of the frequency change of electromagnetic radiation. Resonance absorption in Fe57 has been studied in detail. The strength of the absorption, the line shape, and line shift have all been observed as a function of temperature. The polarization of the radiation has been examined by means of experiments with magnetized sources and absorbers. The hyperfine spectrum of the resonance radiation has been analysed with and without polarization. These studies have led to an interpretation of the hyperfine structure in terms of the properties of the nuclear states and the hyperfine interaction in iron. The effect of an external magnetic field on the hyperfine structure has also been investigated. The resonance absorption in Fe{sup 57} has been used to study the connexion between the time development of the decay of a nuclear state and the spectrum of the observed radiation. Detailed observations are made of the time spectrum of filtered resonance radiation for a variety of conditions. (author) [French] L'emission et l'absorption de rayonnements nucleaires sans recul, phenomenes mis en evidence par Mossbauer, offrent un moyen simple d'etudier l'interaction des noyaux et des rayonnements electromagnetiques et, ce qui est plus important encore, fournissent un instrument extremement sensible pour l'etude d'un grand nombre de problemes de physique. Une situation tres favorable se presente dans le cas du noyau de {sup 57}Fe, ou l'on peut utiliser l'absorption par resonance comme un detecteur tres sensible des changements de frequence des rayonnements

  5. Foundations of radiation physics and radiation protection. 5. ed.; Grundlagen der Strahlungsphysik und des Strahlenschutzes

    Energy Technology Data Exchange (ETDEWEB)

    Krieger, Hanno

    2017-07-01

    The following topics are dealt with: Types of radiation and radiation fields, the atomic structure, radioactive decays, decay law, natural and artificial radioactivity, interactions of ionizing photon radiation, attenuation of neutral-particle beams, interactions of neutron radiation, interactions of charged particles, ionization and energy transfer, radiation doses, radiation protection phantoms, foundations of the radiation biology of cells, effects and risks of ionizing radiation, radiation expositions of men with ionizing radiation, radiation protection law, practical radiation protection against ionizing radiations, radiation eposures in medical radiology. (HSI)

  6. About particular use of ionizing radiations; Des usages particuliers des rayonnements ionisants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-02-01

    Different uses of ionizing radiations are reviewed: tracers techniques, nuclear gauges, dating by carbon 14, silica doping, use of gamma irradiation for the density measurement in civil engineering, use of a electron capture detector to study by gas chromatography chlorinated contaminants in environment, neutron activation as environmental gauge, analysis of lead in paint and pollutants in ground and dusts, help for work of art valuation by x spectrometry. (N.C.)

  7. Use of a new ion-detector in the study of the jet plasma injected into a pulsed magnetic mirror configuration (deca I); Utilisation d'un nouveau detecteur d'ions dans l'etude du jet de plasma injecte dans deca I

    Energy Technology Data Exchange (ETDEWEB)

    Renaud, C [Association Euratom-CEA Cadarache, Groupe de Recherches sur la Fusion Controlee, 13 - Saint-Paul-lez-Durance (France). Centre d' Etudes Nucleaires

    1963-07-01

    The study of a high sensitivity ion detector coupled to an electrostatic analyser has permitted a large investigation of the plasma jet injected into a pulsed magnetic mirror configuration. In this detector the positive ions are accelerated through a potential of 30 kV; they strike a metallic target, on which they produce secondary electrons; these, in turn, are accelerated onto a plastic scintillator. The light pulses are detected with a photomultiplier. The gain of this device is about 10{sup 7}. If we make an admission of air into the vacuum system and again we make vacuum, the gain is not modified, since no special activated surfaces are situated in the detector. (author) [French] L'etude d'un detecteur d'ions de grande sensibilite, allie a un analyseur electrostatique a permis une investigation approfondie du jet de plasma injecte dans le dispositif d'Etude de Compression Adiabatique. Dans ce detecteur, les ions positifs sont acceleres par une difference de potentiel voisine de 30 kV, ils bombardent une cible metallique et creent des electrons secondaires qui sont a leur tour acceleres vers un scintillateur plastique. Les impulsions lumineuses sont alors detectees par un photomultiplicateur. Le gain obtenu pour l'ensemble du detecteur est voisin de 10{sup 7}. Le detecteur ne possedant pas de surfaces specialement activees, les remises a l'air n'entrainent pas de variation de gain. (auteur)

  8. Studies on the gamma-gamma method. Definition of an apparatus for on-the-spot measurement of uranium ore densities; Etudes sur la methode gamma-gamma. Determination d'un appareillage pour la mesure en place de la densite des minerais d'uranium

    Energy Technology Data Exchange (ETDEWEB)

    Czubek, J A [Institut de Recheches Nucleaires, Dept. 6, Cracovie (Poland); Guitton, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1966-07-01

    The work described follows on to the research published in report CEA-R--2720 in march 1965. It includes: - experimental results obtained with a model composed of a constant density material (graphite); - the drawing-up of calibration curves using the similitude principle; - determination of the characteristics of a gamma-gamma probe, together with a discussion. The influence is studied of a certain number of parameters on the shape of the energy spectra of scattered radiation, and of the calibration curves: nature of the radioactive source, diameter of the probe area, source detector distance, geometrical shape of shielding between the source and the detector. An attempt is made to find a mathematical model for the calibration curve, for given conditions. Numerical applications make it possible to establish the optimum technical characteristics for a probe measuring the density with the smallest statistical error. (authors) [French] Les travaux decrits font suite aux etudes presentees dans le rapport CEA-R--2720 de mars 1965. Ils portent sur: - les resultats experimentaux obtenus sur un modele constitue d'un materiau de densite constante (graphite) ; - l'etablissement de courbes d'etalonnage a l'aide du principe de similitude; - la recherche et la discussion des caracteristiques d'une sonde gamma-gamma. L'influence d'un certain nombre de parametres sur la forme des spectres d'energie du rayonnement diffuse et des courbes d'etalonnage est etudiee: nature de la source radioactive, diametre du sondage, distance source-detecteur, forme geometrique du blindage entre la source et le detecteur. Pour des conditions determinees, le modele mathematique de la courbe d'etalonnage est recherche. Des applications numeriques permettent d'etablir les caracteristiques techniques optimales d'une sonde mesurant la densite avec la plus faible erreur statistique. (auteurs)

  9. Dislocations and radiation damage in {alpha}-uranium; Dislocations et effets des radiations dans l'uranium {alpha}

    Energy Technology Data Exchange (ETDEWEB)

    Leteurtre, J. [Commissariat a l' Energie Atomique, 92 - Fontenay-Aux-Roses (France). Centre d' Etudes Nucleaires

    1968-07-01

    Dislocations in {alpha}-uranium were studied by electron microscopy. Electropolishing of thin foils was performed at low temperature (-110 deg. C) to prevent oxidation. Burgers vectors of twins dislocations are defined. Interactions between slip and twinning are studied from both experimental and theoretical point of view. Samples irradiated at several burn-up were examined. In order to explain our micrographic results, and also all information gathered in literature about radiation damage in {alpha}-uranium, a coherent model is propound for the fission particles effects. We analyse the influences of parameters: temperature, dislocation density, impurity content. The number of point defects created by one initial fission is determined for pure and annealed metal. The importance of the self-anneal which occurs immediately in each displacement spike, and the anneal due to a new fission on the damage resulting from a previous fission, are estimated. The focussing distance in [100] direction is found to be about 1000 Angstrom, at 4 deg. K. (author) [French] Ce travail est une etude par microscopie electronique des dislocations induites dans l'uranium {alpha}, soit par deformation plastique, soit par irradiation. Une methode de preparation des lames minces a basse temperature (-110 deg. C) a ete mise au point. Les vecteurs de Burgers des diverses dislocations de macles de ce metal ont ete definis. Les interactions glissements- maclages sont etudiees experimentalement et theoriquement. Des echantillons irradies a divers taux de combustion ont ete examines. Pour expliquer nos resultats micrographiques, et aussi l'ensemble des informations recueillies dans la litterature concernant l'endommagement par irradiation de l'uranium-{alpha}, nous proposons un modele coherent de l'effet des fragments de fission dans ce metal. L'influence des parametres: temperature, densite de dislocations, impuretes est analysee. Le nombre de defauts ponctuels crees

  10. Dislocations and radiation damage in {alpha}-uranium; Dislocations et effets des radiations dans l'uranium {alpha}

    Energy Technology Data Exchange (ETDEWEB)

    Leteurtre, J [Commissariat a l' Energie Atomique, 92 - Fontenay-Aux-Roses (France). Centre d' Etudes Nucleaires

    1968-07-01

    Dislocations in {alpha}-uranium were studied by electron microscopy. Electropolishing of thin foils was performed at low temperature (-110 deg. C) to prevent oxidation. Burgers vectors of twins dislocations are defined. Interactions between slip and twinning are studied from both experimental and theoretical point of view. Samples irradiated at several burn-up were examined. In order to explain our micrographic results, and also all information gathered in literature about radiation damage in {alpha}-uranium, a coherent model is propound for the fission particles effects. We analyse the influences of parameters: temperature, dislocation density, impurity content. The number of point defects created by one initial fission is determined for pure and annealed metal. The importance of the self-anneal which occurs immediately in each displacement spike, and the anneal due to a new fission on the damage resulting from a previous fission, are estimated. The focussing distance in [100] direction is found to be about 1000 Angstrom, at 4 deg. K. (author) [French] Ce travail est une etude par microscopie electronique des dislocations induites dans l'uranium {alpha}, soit par deformation plastique, soit par irradiation. Une methode de preparation des lames minces a basse temperature (-110 deg. C) a ete mise au point. Les vecteurs de Burgers des diverses dislocations de macles de ce metal ont ete definis. Les interactions glissements- maclages sont etudiees experimentalement et theoriquement. Des echantillons irradies a divers taux de combustion ont ete examines. Pour expliquer nos resultats micrographiques, et aussi l'ensemble des informations recueillies dans la litterature concernant l'endommagement par irradiation de l'uranium-{alpha}, nous proposons un modele coherent de l'effet des fragments de fission dans ce metal. L'influence des parametres: temperature, densite de dislocations, impuretes est analysee. Le nombre de defauts ponctuels crees par une fission dans du metal

  11. Detailed design of a fixed filter-paper alpha-air-monitor with less than 15-min response time; Detecteur d'aerosols contenant des emetteurs alpha, muni d'un papier filtre fixe, a temps de reponse inferieur a quinze minutes; Podrobnaya konstruktsiya vozdushnogo registratora al'fa-chastits s fiksirovannym bumazhnym fil'trom so vremenem srabatyvaniya menee pyatnadtsati minut; Monitor de hoja de papel filtro fija para emisores alfa suspendidos en el aire, cuyo tiempo de reaccion es inferior a 15 minutos

    Energy Technology Data Exchange (ETDEWEB)

    Gentry, W O; Seaborn, G B [Oak Ridge Gaseous Diffusion Plant, Oak Ridge, TN (United States)

    1962-04-15

    monitor features small size and simplicity, with an economy in fabrication, operation, and maintenance not available in other known monitor designs. It provides an alarm within 15 min when uranium dust concentrations exceed 2.1 x 10{sup -10} {mu}c/cm{sup 3} (three and one-half times the maximum permissible concentration for a 40-h week exposure). Additionally, it can be used to measure the average weekly uranium dust concentration by the removal of the filter disc and the measurement of its radiation level after an appropriate decay period. (author) [French] Dans une usine de separation des isotopes de l'uranium par diffusion gazeuse, les particules alpha emises par les aerosols d'uranium posent un grave probleme de radioprotection. A l'usine de separation par diffusion gazeuse d'Oak Ridge on a entrepris, il y a quelques annees, l'execution d'un programme qui a pour objet de perfectionner les appareils de detection des aerosols. Le memoire decrit un appareil recemment mis au point qui declenche rapidement un avertisseur si le degagement d'aerosols d'uranium atteint le seuil de danger. Avant la mise au point de cet appareil, il fallait attendre cinq heures environ pour permettre la decroissance de la radioactivite naturelle de l'atmosphere avant que les emetteurs alpha a longue periode contenus dans les aerosols d'uranium ne puissent etre deceles. Le fonctionnement de l'appareil considere est fonde sur le principe suivant: lorsque l'on recueille des aerosols contenant des produits de filiation du radon a l'etat naturel dans l'atmosphere, l'activite augmente jusqu'a ce qu'elle atteigne une valeur de quasi-equilibre. A ce moment, la vitesse de depot sera egale a celle de la decroissance. La presence d'aerosols d'uranium entraine une modification rapide des conditions d'equilibre, que l'on peut observer. L'appareil a ceci de particulier qu'un circuit special de differentiation actionne un avertisseur des que le taux d'accroissement de la radioactivite depasse celui auquel on

  12. Mesure des couplages trilineaires anomaux des bosons de jauge avec le detecteur OPAL au LEP

    Science.gov (United States)

    Trigger, Isabel Marian

    Since 1996, the Large Electron-Positron collider (LEP) at CERN has run at energies sufficiently high for the pair production of electroweak gauge bosons. This permits stringent new tests of the Standard Model of particle physics, which makes very precise predictions of the force and nature of the couplings between these bosons. Two of the possible production processes for W+W- pairs are e+e - --> Z0/γ --> W+W -, which involve W+W-Z 0 and W+W-γ couplings. A detailed study of W+W- events can be used to verify the non-Abelian nature of electroweak interactions, and also, eventually, to probe for phenomena arising from physics beyond the Standard Model. The existence of certain new heavy particles, for example, might result in anomalous couplings. We measure the W+W-Z0 and W+W-γ couplings directly, from the rate of W+W- production in the OPAL detector and from characteristics of the decay product distributions of these events. There are three possible final states for W+W - decays: (i) two oppositely charged leptons and missing energy (W+W- --> l - n l+ n ); (ii)one charged lepton, two jets and missing energy (W+W- --> qq¯l n ); or (iii)four hadronic jets (W+W - --> qq¯qq¯). This thesis principally describes the four-jet decays. This is a complicated final state to reconstruct, as the kinematics of the event must be used to determine which of three possible jet pairings corresponds to the true W+ and W- , and in order to increase the sensitivity to anomalous couplings, it is also necessary to use the charges and momenta of the hadrons in the jets to reconstruct the charge of each W. The angular distributions of the W+/- and of their decay products are directly related to the helicities of the Ws, and provide an insight into the nature of the gauge boson couplings.

  13. Study of the radiation around a high energy accelerator. Production and scattering of cascade neutrons; Etude du rayonnement autour d'un accelerateur de haute energie. Production et diffusion des neutrons de cascade

    Energy Technology Data Exchange (ETDEWEB)

    Tardy-Joubert, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1966-03-01

    The cascade induced in protective screens by a 3 GeV proton beam has been studied using activation detectors; the results have been compared with the cosmic neutron spectrum in the atmosphere. A study of the secondary neutron spectrum has made, it possible to obtain the distribution of the dose and to determine the maximum permissible fluxes expressed in terms of the energy, taking into account all the daughter products present. The dose calculated has been checked experimentally. The proportion of cascade neutrons has been studied using the idea of an imaginary source. The parameters which have to be introduced into the general equations to take into account scattering in the the air have been determined. (author) [French] La cascade induite dans les ecrans de protection par un faisceau de protons de 3 GeV a ete etudiee au moyen de detecteurs a activation et la comparaison a ete faite avec le spectre des neutrons cosmiques dans l'atmosphere. L'etude du spectre des neutrons secondaires a permis de preciser la distribution de la dose et de determiner les flux maximaux admissibles qui sont exprimes en fonction de l'energie, en tenant compte de l'ensemble des descendants presents. La dose calculee a ete verifiee experimentalement. La propagation des neutrons de cascade a ete etudiee en introduisant la notion de source fictive. Les parametres a introduire dans les equations generales pour rendre compte de la diffusion dans l'air ont ete determines. (auteur)

  14. Liver late effects of ionizing radiation; Effets tardifs des radiations sur le foie

    Energy Technology Data Exchange (ETDEWEB)

    Mornex, F.; Ramuz, O. [Centre Hospitalier Universitaire Lyon-Sud, 69 - Pierre-Benite (France); Gerard, F. [Laboratoire Marcel-Merieux, 69 - Lyon (France); Van Houtte, P. [Institut Bordet, Brussels (Belgium)

    1997-12-01

    Until recently, the liver was classified as a radioresistant organ, although it is in fact highly radiosensitive. The realization that the whole liver could be treated safety only with low doses of radiation led to the conclusion that radiation therapy had an extremely limited role in the treatment of intrahepatic malignancies. A resurgence of interest has been observed with the advent of conformal radiotherapy and the introduction of bone marrow transplantation with total body irradiation. The radiation-induced liver disease, often called radiation hepatitis, is a syndrome characterized by the development of anicteric ascites, approximately 2 weeks to 4 months after hepatic irradiation. Immediate tolerance is generally surprisingly good, and the subacute radiation injury is followed by a complete asymptomatic healing, although the late lesions may be associated with signs of chronic radiation hepatitis. Radiation hepatitis must be distinguished from chemo-radiation-induced-hepatitis occurring in patients undergoing bone marrow transplantation and total body irradiation. Both syndromes demonstrate the same pathological lesion: veno-occlusive disease. The main treatment for radiation hepatitis is diuretics, although soma advocate steroids for severe cases. (authors)

  15. Preparation and study of the properties of lead telluride and cadmium telluride diodes for use in nuclear spectrometry; Preparation et etude des proprietes de diodes au tellurure de plomb et au tellurure de cadmium en vue d'une utilisation en spectrometrie nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Lancon, R [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1969-07-01

    This work studies the possibility of using high atomic number compound semiconductors, like lead telluride and cadmium telluride as to realize nuclear radiation detectors, specially in gamma ray spectrometry because of their high absorption coefficient. The problems related to the preparation of binary compounds are exposed. Experiments on PbTe show the influence of the conditions of preparation on the electrical properties of the semiconductor which are greatly dependent on the stoichiometry of the compound. PbTe surface-barrier diodes were realized and have been used to study the surface properties of this semiconductor. These diodes cannot detect nuclear radiations because of the too weak resistivity of our material. Different types of devices made of Cd Te have been studied. One of these diodes has been used as an alpha particle detector. We explain the relative poor performances of that detector by the presence of lattice defects in Cd Te where charge carriers may recombine themselves. By analysing the properties of gold diffused Cd Te diodes we identified this defect, the cadmium vacancy, the presence of which is due to the deviation from stoichiometry during the preparation of the material. (author) [French] Ce travail etudie la possibilite d'utiliser des semiconducteurs composes d'elements a numero atomique eleve, tels que le tellurure de plomb et le tellurure de cadmium pour la realisation de detecteurs de rayonnements nucleaires, grace notamment a la section efficace de capture elevee qu'ils presentent vis-a-vis des rayons gamma. On souligne les problemes relatifs a la preparation des composes binaires. Les experiences realisees sur PbTe mettent en evidence l'influence des conditions de preparation sur les proprietes electriques du semiconducteur qui dependent fortement de la stoechiometrie du compose. Nous avons realise des diodes au PbTe a barriere de surface qui ont permis de preciser les proprietes de surface de ce semiconducteur. La trop faible

  16. Aspects of radiation protection during chest X-radiography; Strahlenhygienische Aspekte bei der Roentgenuntersuchung des Thorax

    Energy Technology Data Exchange (ETDEWEB)

    Seidenbusch, M.C.; Schneider, K. [Dr. von Haunersches Kinderspital, Klinikum der Universitaet Muenchen, Institut fuer Klinische Radiologie - Kinderradiologie, Muenchen (Germany)

    2015-07-15

    Radiation safety in conventional X-ray diagnostics is based on the concepts of justification, optimization of an X-ray examination and limitation of the radiation exposure achieved during the examination. Optimization of an X-ray examination has to be considered as a multimodal process in which all technical components of the X-ray equipment have to be adapted to each other and also have to be adapted to the anthropometric characteristics of patients and the clinical indications. In this article the technical components of a conventional pediatric chest X-radiograph are presented, and recommendations for optimizing chest X-rays in children are provided. The following measures are of prime importance: correct x-ray beam limitation, using the posteroanterior projection when possible and not using anti-scatter grids in children under approximately 8 years old. In pediatric radiology chest x-rays that are taken not at the peak of inspiration can also be of some diagnostic significance. Optimization of an X-ray examination inevitably results in the limitation of radiation exposure. (orig.) [German] Die Strahlenhygiene in der konventionellen radiologischen Diagnostik basiert auf der Trias Rechtfertigung, Optimierung bzw. Limitierung der Roentgenuntersuchung bzw. Strahlenexposition. Die Optimierung einer Roentgenuntersuchung ist als multimodaler Prozess aufzufassen, in welchem saemtliche technische Komponenten der Roentgeneinrichtung sowohl miteinander als auch mit den anthropometrischen Eigenschaften des Patienten und der klinischen Fragestellung abzustimmen sind. Im vorliegenden Beitrag werden die technischen Komponenten bei der konventionellen Roentgenuntersuchung des paediatrischen Thorax in ihrer Beziehung zueinander dargestellt und Empfehlungen fuer eine Optimierung der konventionellen Thoraxaufnahme bei Kindern ausgesprochen. Die wichtigsten Massnahmen bestehen in einer korrekten Einblendung, in der Anfertigung der Aufnahmen im posteroanterioren Strahlengang und im

  17. The application of {beta}-ray excitation fluorescence to the measurement of the thickness of deposits and to analysis; Applications de la fluorescence excitee au moyen des rayons {beta} a la mesure des epaisseurs des depots et a l'analyse

    Energy Technology Data Exchange (ETDEWEB)

    Martinelli, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires; Seibel, G [Institut de Recherches de la Siderurgie Francaise (IRSID), 78 - Saint-Germain-en-Laye (France)

    1961-07-01

    Principles of the method are first outlined and the instrumentation used is described. The different types of radiation detectors are subject of a detailed study. As a source of {beta}-radiation {sup 90}(Sr + Y) was used as well as {sup 147}Pm. Great care was taken to eliminate back-diffused electrons by deflection by a strong permanent magnet. The method was applied to the measurement of the thickness of deposits of Cr, Zn, Sn, Cd and Cu on iron as well as Zn, Cr, Ag and Au on copper and the results obtained are discussed. An attempt was made, to use {beta}-X-ray fluorescence for the analysis of minerals, iron ore and glass and for routine control of Si-Mn, Si-Ca, Fe-Mn and Fe-W. Finally the method of {beta}-X-ray fluorescence is compared with normal-X-ray fluorescence and possibilities of further development are cited. (author) [French] Les principes de la methode et l'instrumentation utilisee sont presentes. On decrit en particulier les detecteurs de rayonnement utilises. Comme source de rayonnement on utilise {sup 90}(Sr + Y) et {sup 147}Pm. Pour eliminer les electrons retrodiffuses on utilise un aimant permanent place sur le trajet du faisceau. La methode est appliquee a la mesure des epaisseurs des depots metalliques tels que le Cr, Zn, Sn, Cd et Cu sur fer et le Zn, Cr, Ag et Au sur cuivre. D'autre part, la fluorescence {beta}-X etait utilisee pour l'analyse des minerais et des verres et pour le controle des alliages Fe-Mn, Fe-W, Si-Mn, Si-Ca. Enfin, on passe a une comparaison entre la fluorescence {beta}-X et la fluorescence X normale et on discute les possibilites d'un developpement futur. (auteur)

  18. Nuclear safety and radiation protection report of the Saint-Laurent-des-Eaux nuclear facilities - 2011

    International Nuclear Information System (INIS)

    2012-01-01

    This safety report was established under the article 21 of the French law no. 2006-686 of June 13, 2006 relative to nuclear safety and information transparency. It presents, first, the facilities of the Saint-Laurent-des-Eaux nuclear power plant (Saint-Laurent-Nouan (FR)): 2 partially dismantled graphite-gas reactors and a graphite sleeves storage silo (INB 46 and 74), and 2 PWR reactors in operation (INB 100). Then, the nuclear safety and radiation protection measures taken regarding the facilities are reviewed: nuclear safety definition, radiation protection of intervening parties, safety and radiation protection improvement paths, crisis management, external and internal controls, technical situation of facilities, administrative procedures in progress. The incidents and accidents which occurred in 2011, are reported as well as the radioactive and non-radioactive (chemical, thermal) effluents discharge in the environment. Finally, The radioactive materials and wastes generated by the facilities are presented and sorted by type of waste, quantities and type of conditioning. Other environmental impacts (noise, microbial proliferation in cooling towers) are presented with their mitigation measures. Actions in favour of transparency and public information are presented as well. The document concludes with a glossary and a list of recommendations from the Committees for health, safety and working conditions. (J.S.)

  19. Nuclear safety and radiation protection report of the Saint-Laurent-des-Eaux nuclear facilities - 2010

    International Nuclear Information System (INIS)

    2011-06-01

    This safety report was established under the article 21 of the French law no. 2006-686 of June 13, 2006 relative to nuclear safety and information transparency. It presents, first, the facilities of the Saint-Laurent-des-Eaux nuclear power plant (Saint-Laurent-Nouan (FR)): 2 partially dismantled graphite-gas reactors and a graphite sleeves storage silo (INB 46 and 74), and 2 PWR reactors in operation (INB 100). Then, the nuclear safety and radiation protection measures taken regarding the facilities are reviewed: nuclear safety definition, radiation protection of intervening parties, safety and radiation protection improvement paths, crisis management, external and internal controls, technical situation of facilities, administrative procedures in progress. The incidents and accidents which occurred in 2010, are reported as well as the radioactive and non-radioactive (chemical, thermal) effluents discharge in the environment. Finally, The radioactive materials and wastes generated by the facilities are presented and sorted by type of waste, quantities and type of conditioning. Other environmental impacts (noise, microbial proliferation in cooling towers) are presented with their mitigation measures. Actions in favour of transparency and public information are presented as well. The document concludes with a glossary and a list of recommendations from the Committees for health, safety and working conditions. (J.S.)

  20. Uses of radioactive isotopes and radiation sources in biological studies in U. A. R; Utilisation des radioisotopes et des sources de rayonnement dans les etudes biologiques en RAU

    Energy Technology Data Exchange (ETDEWEB)

    Hashish, S. E. [Radiobiology Department, U. A. R. Atomic Energy Establishment, Cairo, United Arab Republic (Egypt)

    1970-01-15

    An attempt is made to give examples rather than a review of the uses of radioactive isotopes and radiation sources in biological studies in U.A.R. Studies along these lines started early in 1955 and are still progressing. The prospects of future developments and improvements are unlimited. The studies are classified according to the radio technique adopted. The techniques so far used in U.A.R. include all the techniques known elsewhere. Some detailed modifications and combinations of more than one technique have been successfully introduced. Both in basic and applied biological studies, one or more of the following techniques have been applied, namely tracer technique, isotopic dilution analysis, autoradiography, radiochromatography and electrophoresis, double or multi-bioassays, radioactivation analysis, neutron absorption analysis, and use of different radiation source for somatic and/or genetic effect studies. Mass spectrometry for stable isotopic studies in the field of biology has been recently used. Studies undertaken in the applied fields of biology e. g, in medicine (diagnosis and therapy) and agriculture (soil, plant and animal) have proved extremely valuable from the practical and developmental points of view. (author) [French] Le mémoire a pour objet d'illustrer plutôt que d'exposer systématiquement les utilisations des radioisotopes et des sources de rayonnement dans des études biologiques en République Arabe Unie. Ces études, entreprises au début de 1955, se poursuivent. Les possibilités de développement et de perfectionnement sont illimitées. Les études sont classées d'après la radiotechnique adoptée. Les techniques régulièrement utilisées jusqu' à présent en République Arabe Unie couvrent toute la gamme des techniques connues ailleurs. On a réussi à apporter des modifications de détail et à combiner plusieurs techniques. Dans les études de biologie tant fondamentale qu' appliquée, une ou plusieurs des techniques suivantes

  1. Study of cerenkov radiation. Production of {gamma} rays by electron accelerators; Etude du rayonnement de freinage. Production de rayons {gamma} par des accelerateurs d'electrons

    Energy Technology Data Exchange (ETDEWEB)

    Bernard, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    This study is a critical comparison of the theories of Bremsstrahlung. Experimental results obtained by the production of {gamma} radiation with electron accelerators are compared to the theoretical results in order to estimate the extent to which the various theories are valid. (author) [French] Cette etude est une synthese des theories du rayonnement de freinage. Des resultats experimentaux, obtenus par la production de rayonnements {gamma} avec des accelerateurs d'electrons, sont compares aux resultats theoriques afin d'evaluer les domaines de validite des diverses theories. (auteur)

  2. Effets de rayonnement sur les detecteurs au silicium a pixels du detecteur ATLAS

    CERN Document Server

    Lebel, Celine

    2007-01-01

    Two detection systems are using pixel silicon detectors in the ATLAS detector: the Pixel, which is the subdetector closest to the interaction point, and the MPX network. The activation of the materials present in the Pixel produced by radiation has been measured in two experiments which we performed at CERF (CERN) and NPI-ASCR (Czech Republic). These experimental studies of activation are com- pared with GEANT4 simulations. The results of these comparisons show that the simulation can predict the activities with a precision of an order of magnitude. They also show that GEANT4 fails to produce certain radioisotopes seen in the experimental activation studies. The contribution to background and the resid- ual doses due to the desintegration of the radioisotopes produced by fast neutrons (category in which falls the expected average neutron energy of 1 MeV in ATLAS) are extrapolated to ATLAS conditions. It is found that this background in the AT- LAS Pixel subdetector will be negligible and that the doses are we...

  3. Electronic sorting of radioactive ores; Triage electronique des minerais radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    Sandier, J.

    1958-01-15

    Electronic sorting of radioactive ores consists in passing the rock lumps, after sieving, one by one in front of radioactivity detectors; these detectors command electromechanical systems which class the ores according to their radioactivity level. This note sets on the state of progress of the work going on at the D.R.E.M.: use of scintillometers for γ-ray detection, with circuits carrying magnetic memories to improve their operation; results of laboratory and semi-industrial tests on several deposits; description of the material, data on the first factory project; notes on the financial returns of the process. A description is also given of the electronic sorting material used skip by skip for a first rough classification of the ores according to their content, as they leave the shaft. (author) [French] Le triage electronique des minerais radioactifs consiste a faire passer, apres criblage, les cailloux un par un devant des detecteurs de radioactivite; ces detecteurs commandent des systemes electromecaniques qui classent les minerais selon leur niveau de radioactivite. La note expose l'etat d'avancement des travaux en cours a la D.R.E.M: utilisation des scintillometres pour la detection des rayonnements γ, de circuits comportant des memoires magnetiques pour ameliorer le fonctionnement; resultats d'essais de laboratoire et semi-industriels sur plusieurs gisements; description du materiel, donnees sur le premier projet d'usine; notes sur la rentabilite du procede. Est egalement decrit le materiel de triage electronique skip par skip utilise pour une premiere classification grossiere des minerais selon leurs teneurs, des la sortie des puits. (auteur)

  4. Detection of fission fragments by secondary emission; Detection des fragments de fission par emission secondaire

    Energy Technology Data Exchange (ETDEWEB)

    Audias, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-07-01

    This fission fragment detecting apparatus is based on the principle that fragments traversing a thin foil will cause emission of secondary electrons. These electrons are then accelerated (10 kV) and directly detected by means of a plastic scintillator and associated photomultiplier. Some of the advantages of such a detector are, its rapidity, its discriminating power between alpha particles and fission fragments, its small energy loss in detecting the fragments and the relatively great amount of fissionable material which it can contain. This paper is subdivided as follows: a) theoretical considerations b) constructional details of apparatus and some experimental details and c) a study of the secondary emission effect itself. (author) [French] Le detecteur de fragments de fission que nous avons realise est base sur le principe de l'emission secondaire produite par les fragments de fission traversant une feuille mince: les electrons secondaires emis sont acceleres a des tensions telles (de l'ordre de 10 kV), qu'ils soient directement detectables par un scintillateur plastique associe a un photomultiplicateur. L'interet d'un tel detecteur reside: dans sa rapidite, sa tres bonne discrimination alpha, fission, la possibilite de detecter les fragments de fission avec une perte d'energie pouvant rester relativement faible, et la possibilite d'introduire des quantites de matiere fissile plus importantes que dans les autres types de detecteurs. Ce travail comporte: -) un apercu bibliographique de la theorie du phenomene, -) realisation et mise au point du detecteur avec etude experimentale de quelques parametres intervenant dans l'emission secondaire, -) etude de l'emission secondaire (sur la face d'emergence des fragments de fission) en fonction de l'energie du fragment et en fonction de l'epaisseur de matiere traversee avant emission secondaire, et -) une etude comparative de l'emission secondaire sur la face d'incidence et sur la face d'emergence des fragments de

  5. Response of hematopoietic stem cells to ionizing radiation; Reponse des cellules souches hematopoitiques aux radiations ionisantes

    Energy Technology Data Exchange (ETDEWEB)

    Simonnet, A

    2008-12-15

    Hematopoietic stem cells (HSCs) maintain blood and immune system throughout life and restore them after hematological injuries. Exposure of an organism to ionizing radiation (IR) causes rapid and acute myelosuppression and challenges the replenishment capacity of HSCs. Yet, the precise damages that are generated remain largely unexplored. To better understand these effects, phenotypic and functional changes in the stem/progenitor compartments of sublethally irradiated mice were monitored over a ten week period after radiation exposure. We report that shortly after sublethal IR-exposure, HSCs, defined by their repopulating ability, still segregate in the Hoechst dye excluding side population (SP); yet, their Sca-1 (S) and c-Kit (K) expression levels are increased and severely reduced, respectively, with a concurrent increase in the proportion of SP{sup SK} cells positive for established indicators of HSC presence: CD150{sup +} and CD105{sup +}. A great proportion of HSCs quickly but transiently enter the cell cycle to replenish the bone marrow of myelo-ablated mice. Ten weeks after, whereas bone marrow cellularity has recovered and hematopoietic homeostasis is restored, major phenotypic modifications can be observed within the Lin{sup -/low} Sca-1{sup +} c-Kit{sup +} (LSK) stem/progenitor compartment: CD150{sup +}/Flk2{sup -} and CD150{sup -}/Flk2{sup +} LSK cell frequencies are increased and dramatically reduced, respectively. CD150{sup +} LSK cells also show impaired reconstitution capacity, accrued number of {gamma}-H2AX foci and increased tendency to apoptosis. This demonstrates that the LSK compartment is not properly restored 10 weeks after sublethal exposure, and that long-term IR-induced injury to the bone marrow proceeds, at least partially, through direct damage to the stem cell pool. Thrombopoietin (TPO) has been shown to promote the survival of lethally irradiated mice when administrated quickly after exposure. We investigated the mechanisms underlying

  6. The construction of standardised equipment expressly adapted to the different methods of radiation control; Realisation de materiel standardise specialement adapte aux divers modes de controle des radiations

    Energy Technology Data Exchange (ETDEWEB)

    Savouyaud, J; Menoux, A [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    The authors show what general characteristics must have equipment designed for radiation control. This equipment must make possible the measurement of doses corresponding to 1/10 of the maximum permissible limit. It should be designed for a specific purpose, and finally it should be independent as far as possible. The authors review the different types of control which it is necessary to effect. (author) [French] Les auteurs indiquent quelles doivent etre les caracteristiques generales du materiel de controle des radiations. Ce materiel doit permettre l'appreciation de mesures correspondant au 1/10{sup e} des limites maximales admissibles. Il devrait etre concu pour une fonction determinee, enfin, il doit etre dans la mesure du possible, autonome. Les auteurs passent en revue les differents types de controle qu'il est necessaire de couvrir. (auteur)

  7. Radiation Disinfestation of Grain and Seeds; Radiodesinsection des Cereales et des Semences; Obezzarazhivanie zerna i semyan s pomoshch'yu oblucheniya; Desinfestacion de Granos y Semillas por Irradiacion

    Energy Technology Data Exchange (ETDEWEB)

    Golumbic, C.; Davis, D. F. [Market Quality Research Division, Agricultural Research Service, United States Department of Agriculture, Hyattsville, MD (United States)

    1966-11-15

    Current interest in radiation treatment of grain and seeds mainly revolves about its efficacy for control of insect infestations in these products. The recent literature on this subject is reviewed and gaps still existing in the fundamental and practical knowledge of radiation disinfestation.are pointed out. Research programmes in the United States Department of Agriculture that are under way, or planned for the immediate future, are discussed in detail. Current studies are being directed toward establishing minimum effective doses for sexual sterilization and mortality, influence of environmental factors on dose requirements, and potential for the development of biological resistance. In May 1966 the scope of the work expanded as a new grain products irradiator became operative and applied studies were initiated. An integral part of this, research is a study of the effect of irradiation on the quality of food and feed grains and on cereal products, at the doses for both insect control and fungal disinfection. This paper examines critically the results of research in this area and estimates future research, needs. (author) [French] A'.l'heure actuelle, l'interet que suscite le traitement par les rayonnements des cereales et des semences est du avant tout a son efficacite pour la desinsection. Les auteurs analysent les recentes publications dans ce domaine et. signalent les lacunes, qui subsistent encore dans les connaissances fondamentales ou pratiques relatives a la radiodesinsection, ' Ils examinent en detail les programmes de recherches du Departement de l'agriculture des Etats-Unis qui sont actuellement mis.en oeuvre ou projetes pour l'avenir immediat. Les etudes actuelles concernent la determination de la dose minimale necessaire pour la sterilisation sexuelle et de la dose mortelle, l'influence des facteurs ambiants sur les doses requises, et les possibilites de developpement de la resistance biologique. En mai 1966, les travaux se sont elargis a la suite de

  8. New recording methods and electromechanical analysis; Nouvelles methodes d'enregistrement et de depouillement electromecanique des numerations de particules

    Energy Technology Data Exchange (ETDEWEB)

    Meunier, R.; Bonpas, M.; Legrand, J.P. [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires

    1954-07-01

    The measurement that the most often occurs in nuclear physics are of the numerations of pulses representing the transit of a particle in a detector that can be a Geiger counter, a photomultiplier or a pulse chamber. We studied and constructed an electromagnetic recorder who permits to get automatically and without calculation: 1) the activity of a radioelement according to the time; 2) the curve of decrease of a radioelement and its period; 3) any curves of growth or decrease; 4) the activity, at any instant, of a neutron detector; 5) the neutron densities ratios in several points by the method of the detectors. (M.B.) [French] Les mesures qui se presentent le plus souvent en physique nucleaire sont des numerations d'impulsions representant le passage d'une particule dans un detecteur qui peut etre un compteur de Geiger, un photomultiplicateur ou une chambre a impulsions. Nous avons etudie et construit un enregistreur electromagnetique qui permet d'obtenir automatiquement et sans calcul: 1) l'activite d'un radioelement en fonction du temps; 2) la courbe de decroissance d'un radioelement et sa periode; 3) des courbes quelconques de croissance ou de decroissance; 4) l'activite, rapportee a un instant quelconque, d'un detecteur de neutrons; 5) les rapports des densites de neutrons en plusieurs points par la methode des detecteurs. (M.B.)

  9. New recording methods and electromechanical analysis; Nouvelles methodes d'enregistrement et de depouillement electromecanique des numerations de particules

    Energy Technology Data Exchange (ETDEWEB)

    Meunier, R; Bonpas, M; Legrand, J P [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires

    1954-07-01

    The measurement that the most often occurs in nuclear physics are of the numerations of pulses representing the transit of a particle in a detector that can be a Geiger counter, a photomultiplier or a pulse chamber. We studied and constructed an electromagnetic recorder who permits to get automatically and without calculation: 1) the activity of a radioelement according to the time; 2) the curve of decrease of a radioelement and its period; 3) any curves of growth or decrease; 4) the activity, at any instant, of a neutron detector; 5) the neutron densities ratios in several points by the method of the detectors. (M.B.) [French] Les mesures qui se presentent le plus souvent en physique nucleaire sont des numerations d'impulsions representant le passage d'une particule dans un detecteur qui peut etre un compteur de Geiger, un photomultiplicateur ou une chambre a impulsions. Nous avons etudie et construit un enregistreur electromagnetique qui permet d'obtenir automatiquement et sans calcul: 1) l'activite d'un radioelement en fonction du temps; 2) la courbe de decroissance d'un radioelement et sa periode; 3) des courbes quelconques de croissance ou de decroissance; 4) l'activite, rapportee a un instant quelconque, d'un detecteur de neutrons; 5) les rapports des densites de neutrons en plusieurs points par la methode des detecteurs. (M.B.)

  10. The place of ionizing radiation in the cancer genesis; La place des rayonnements ionisants dans la genese des cancers

    Energy Technology Data Exchange (ETDEWEB)

    Simon, J. [Societe Francaise d' Energie Nucleaire, 75 - Paris (France)

    2009-12-15

    Two different fields are considered: the field of high radiation doses (over 1 Sv), the contribution of ionizing radiation in the carcinogenesis is doubtless and the linear dose-effect relationship is unshakable. but this high doses area is rare ( major accident of civil nuclear, radiotherapy, war with use of nuclear weapon) and escapes to usual standards. The field of low dose irradiation (inferior to 100 MSv) we cannot assure the absence of carcinogen risk of ionizing radiation. We can tell that this risk is very low, very inferior to 5% by sievert accepted by the ICRP in conformance with the precautionary principle. In any case, very inferior to the risk in relation with the big causes of cancer that are addiction to smoking, (30% of cancers), food (30% of cancers), chronic diseases (11% of cancers) and hormonal processes (10% of cancers). (N.C.)

  11. Patients radiation protection in medical imaging. Conference proceedings; Radioprotection des patients en imagerie medicale. Recueil des presentations

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-12-15

    This document brings together the available presentations given at the conference organised by the French society of radiation protection about patients radiation protection in medical imaging. Twelve presentations (slides) are compiled in this document and deal with: 1 - Medical exposure of the French population: methodology and results (Bernard Aubert, IRSN); 2 - What indicators for the medical exposure? (Cecile Etard, IRSN); 3 - Guidebook of correct usage of medical imaging examination (Philippe Grenier, Pitie-Salpetriere hospital); 4 - Radiation protection optimization in pediatric imaging (Hubert Ducou-Le-Pointe, Aurelien Bouette (Armand-Trousseau children hospital); 5 - Children's exposure to image scanners: epidemiological survey (Marie-Odile Bernier, IRSN); 6 - Management of patient's irradiation: from image quality to good practice (Thierry Solaire, General Electric); 7 - Dose optimization in radiology (Cecile Salvat (Lariboisiere hospital); 8 - Cancer detection in the breast cancer planned screening program - 2004-2009 era (Agnes Rogel, InVS); 9 - Mammographic exposures - radiobiological effects - radio-induced DNA damages (Catherine Colin, Lyon Sud hospital); 10 - Breast cancer screening program - importance of non-irradiating techniques (Anne Tardivon, Institut Curie); 11 - Radiation protection justification for the medical imaging of patients over the age of 50 (Michel Bourguignon, ASN); 12 - Search for a molecular imprint for the discrimination between radio-induced and sporadic tumors (Sylvie Chevillard, CEA)

  12. Determination of the mass of W boson at LEP2 with ALEPH detector by studying energy spectra of leptons; Determination de la masse du boson W a LEP2 avec le detecteur ALEPH par l'etude du spectre d'energie des leptons

    Energy Technology Data Exchange (ETDEWEB)

    Dessagne-Trescarte, S

    2000-07-07

    One of the most significant goals of the LEP is to test with precision the Electroweak Standard Model. Whereas the first step was mainly centered on the study of the Z boson, the second phase, LEP200, allowed the study of the proprieties of the W boson. Thus, the mass of the W is a fundamental parameter of the Standard Model and its measurement is a very significant stake to test this model and to predict the mass of the Higgs boson through radiative corrections. LEP200 is well adapted to the study of the mass of the W boson, because the centre-of-mass energy is above the kinematic threshold, {radical}S = 2M{sub W}, and thus makes it possible to produce W{sup +}W{sup -} pairs through the process e{sup +}e{sup -} {yields} W{sup +}W{sup -}. The data collected by the ALEPH detector during the years 1997 and 1998 at the centre-of-mass energy of respectively 183 GeV and 189 GeV have been used in this thesis to perform a measurement of M{sub W} based on the comparison of distributions sensitive to M{sub W}, and built using the data and Monte Carlo samples generated at different W masses. Two types of methods can be used to estimate the W mass: the direct reconstruction of M{sub W} (using as estimator the invariant mass obtained after a 2C kinematic fit) or the measurement of M{sub W} through the WW cross section. This thesis proposes a new technique of direct reconstruction based on the use of the W {yields} l{nu} channel. The distributions used in the semileptonic channel are the energies of the lepton and of the neutrino calculated in the laboratory frame and in the centre-of-mass of the W, the lepton-neutrino invariant mass and the boost of the W. In the leptonic channel, the three distributions used are the energy of the most energetic lepton, the energy of the second lepton and the missing energy of the event. In the leptonic channel, WW {yields} l{nu}l{nu}, one gets: M{sub W} = 81.409 {+-} 0.565(Stat) {+-} 0.125(Syst) GeV/c{sup 2}. In the semileptonic channel WW

  13. Dosimetry techniques of thermal neutrons and {gamma} radiation in reactor cores; Techniques de dosimetrie des neutrons thermiques et du rayonnement {gamma} dans les piles

    Energy Technology Data Exchange (ETDEWEB)

    Sutton, J; Draganic, I; Hering, H [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1955-07-01

    Chemical studies under radiation done in the reactor cores require to be followed by dosimetry. When the irradiations are done in the reflector, one can limit to the measure of the {gamma} and the neutron radiation. For the dosimetry of the {gamma} radiation, a dosimeter of ferrous sulfate is convenient until doses of about 10{sup 6} rep. The use of aired oxalic acid solutions permits to reach 10{sup 7} rep. The dosimetry of thermal neutrons has been made with solutions of cobalt sulphate or paper filter impregnated with this salt. The total chemical effect of the {gamma} and of the slow neutrons radiation is obtained with solutions of ferrous sulfate added with lithium sulphate. (M.B.) [French] Les etudes de chimie sous radiation faites dans les piles exigent d'etre suivies par dosimetrie. Lorsque les irradiations sont effectues dans le reflecteur, on peut se limiter a doser le rayonnement {gamma} et les neutrons. Pour la dosimetrie du rayonnement {gamma}, un dosimetre a sulfate ferreux convient jusqu'a des doses d'environ 10{sup 6} rep. L'emploi de solutions aerees d'acide oxalique permet d'atteindre 10{sup 7} rep. La dosimetrie des neutrons thermiques a ete faite avec des solutions de sulfate de cotalt ou du papier filtre impregne de ce sel. L'effet chimique total du rayonnement {gamma} et des neutrons lents est obtenu avec des solutions de sulfate ferreux additionne de sulfate de lithium. (M.B.)

  14. Treatment modalities of oral mucositis after radiation of head and neck cancers; Prise en charge des mucites apres radiotherapie des cancers des voies aerodigestives superieures

    Energy Technology Data Exchange (ETDEWEB)

    Lapeyre, M.; Charra-Brunaud, C.; Kaminsky, M.C.; Geoffrois, L.; Dolivet, G.; Pourel, N.; Marchal, C.; Bey, P.; Maire, F.; Simon, M. [Centre Alexis-Vautrin, 54 - Vandoeuvre-les-Nancy (France); Toussaint, B. [Hopital Central, Service de Chirurgie ORL, 54 - Nancy (France)

    2001-11-01

    Acute mucositis is common after radiotherapy for head and neck cancers. During the past 3 decades, there was a gradual evolution in the treatment modalities for locally advanced carcinomas (concomitant radio-chemotherapy, accelerated radiotherapy). These new strategies are accompanied by an increase in early mucosal reactions. At the present time, there is no widely accepted prophylaxis or effective treatment. Many traditional remedies or new agents seem ineffective (Sucralfate, Chlorhexidine, GM-CSF, Silver nitrate, Prostaglandin, anti-oxidants, Benzydamine hydrochloride), while others seem promising (Povidone-iodine, nonabsorbable antibiotic lozenges and anti-fungal, local GM-CSF, Glutamide, Low-energy laser, corticosteroids). Radioprotectors are controversial and should be only used in experimental protocols and not in routine practice. However, some recommendations can be proposed: general prevention and global care before cancer therapy should be systematic (oral hygiene, dental and periodontal treatment, advice to avoid the use of tobacco and alcohol); frequent oral rinsing with a bland mouthwash (Povidone-iodine or others) should be used at the start of treatment because there are significant modifications of the oral microflora increased by a disturbed salivary flow; these mouthwashes could be associated with nonabsorbable antibiotic lozenges or anti-fungal topical (bicarbonates, Amphotericine B); Systematic percutaneous fluoroscopic gastrostomy should be decided before any aggressive treatments (concomitant radio-chemotherapy, accelerated radiotherapy); pain should be controlled; finally, the radiation technique should be optimized (mucosal sparing block, conformal radiotherapy and intensity modulated radiation therapy). (authors)

  15. Quantitative measurements of small isotopic samples in gaseous mixtures by utilization of some nuclear properties; Etude des possibilites de mesures de faibles quantites de gaz radioactifs dans un melange en utilisant simultanement plusieurs proprietes nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Maragnon, J; Delperie, C

    1967-12-01

    The question is to define the characteristics of a group of measurements allowing the analysis of traces of radioactive rare gases in gas mixtures of different composition. To distinguish the radioactive isotopes from each other and the activity level reaching 10{sup 6} due to their nuclear properties, the method was chosen to use several nuclear properties: gamma radiation energy, beta particle energy, lifetime of excited states. The choice of a plastic scintillator as beta detector allows to answer satisfactorilly to this demand by measurement of nuclear constants because of the short de/excitation time of this detector. Another advantage is that it can be a reservoir for the sample without any destruction nor modification of the sample. The study has been based on the mixture of Kr-85, the analysis of other rare gases follwos immediately from the adopted principle. [French] Les auteurs ont oriente leur recherche vers une solution permettant de distinguer les isotopes radioactifs les uns des autres et dans des rapports d'activite pouvant atteindre 10{sup 6}, grace a plusieurs de leurs proprietes nucleaires, energie de rayonnement gamma, energie de la particule beta, temps de vie des niveaux excites. Le choix d'un scintillateur plastique comme detecteur beta permet de repondre d'une maniere satisfaisante a la mesure des constantes nucleaires en raison du temps de de/excitation rapide de ce scintillateur. Il offre en outre l'avantage de pouvoir servir de reservoir a l'echantillon sans entrainer aucune destruction ni modification de celui-ci. L'etude a ete basee sur la mixture de Kr-85, l'analyse des autre gaz rares decoulant immediatement du principe adopte. (auteur)

  16. Technique of nuclear reactors controls; Technique des controles des reacteurs nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Weill, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1953-12-15

    This report deal about 'Techniques of control of the nuclear reactors' in the goal to achieve the control of natural uranium reactors and especially the one of Saclay. This work is mainly about the measurement into nuclear parameters and go further in the measurement of thermodynamic variables,etc... putting in relief the new features required on behalf of the detectors because of their use in the thermal neutrons flux. In the domain of nuclear measurement, we indicate the realizations and the results obtained with thermal neutron detectors and for the measurement of ionizations currents. We also treat the technical problem of the start-up of a reactor and of the reactivity measurement. We give the necessary details for the comprehension of all essential diagrams and plans put on, in particular, for the reactor of Saclay. (author) [French] Nous avons aborde le probleme de la ''Technique du Controle des reacteurs nucleaires'' dans le but de realiser le controle du reacteur de Saclay. C'est ainsi que nous avons ete amene a etudier le probleme dans son ensemble, tel qu'il se pose pour tout reacteur a uranium naturel. Ce travail traite principalement du domaine des mesures a caractere nucleaire et s'etend dans le domaine des mesures thermodynamque de niveaux, etc... mettant en relief les caracteristiques nouvelles exigees de la part des detecteurs du fait de leur utilisation dans le flux de neutrons thermiques. Dans le domaine de mesures nucleaires, nous indiquons principalement les realisations et les resultats obtenus pour les detecteurs de neutrons thermiques et pour la mesure de courants d'ionisations. Nous traitons egalement du probleme technique du demarrage d'un reacteur et du probleme de la mesure de la reactivite. Nous donnons les details necessaires a la comrehension de tous les schemas et plans de cablages essentiels mis au point, en particulier, pour le reacteur de Saclay. (auteur)

  17. The n,{gamma} discrimination in recoil-proton proportional counters. Application to the measurement of fast neutron spectra; Discrimination n,{gamma} dans les compteurs proportionnels a protons de recul. Application a la mesure des spectres de neutrons rapides

    Energy Technology Data Exchange (ETDEWEB)

    Jeandidier, C [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    A description is given of a spectrometry chain working in the energy range of a few keV to 1 MeV, and designed for measurement of fast neutron spectra. It consists of detectors, recoil proton proportional counters built especially for this work by R. COMTE (DEG/SER) and which make it possible to cover the energy range and also associated electronic equipment. A brief description is first given of the physical processes involved: (n,p) collisions in the gas, influence of {gamma} radiation; the method of discrimination is then presented. It is based on the difference in the rise-times of the pulses. In the experiments described here the use of a bi-parametric system made it possible to employ the most simple discrimination device, based on the fact that the high frequency gamma pulse components are, at a given energy, weaker than those of the neutron pulses. Results are given of measurements carried out on the Van der Graaff (mono-energetic neutrons for testing the linearity of the chain and the resolving power of the counters), and of those made in a sub-critical system Hug at Cadarache. (author) [French] On decrit une chaine de spectrometrie travaillant dans le domaine d'energie de quelques keV a 1 MeV destinee a la mesure des spectres de neutrons rapides. Elle comprend les detecteurs, compteurs proportionnels a protons de recul, realises specialement pour cette etude par M. R. COMTE (DEG/SER), permettant de couvrir la gamme d'energie et l'electronique associee. Apres un rappel des processus physiques mis en jeu: chocs (n,p) dans les gaz, influence des rayonnements {gamma}, on expose la methode de discrimination utilisee. Celle-ci est basee sur la difference des temps de montee des impulsions. Au cours des experiences rapportees ici, la mise en oeuvre d'un ensemble bi-parametrique a permis d'utiliser le dispositif de discrimination le plus simple, base sur la remarque que les composantes a haute frequence des impulsions {gamma} sont, a energie egale, plus faibles

  18. The n,{gamma} discrimination in recoil-proton proportional counters. Application to the measurement of fast neutron spectra; Discrimination n,{gamma} dans les compteurs proportionnels a protons de recul. Application a la mesure des spectres de neutrons rapides

    Energy Technology Data Exchange (ETDEWEB)

    Jeandidier, C. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    A description is given of a spectrometry chain working in the energy range of a few keV to 1 MeV, and designed for measurement of fast neutron spectra. It consists of detectors, recoil proton proportional counters built especially for this work by R. COMTE (DEG/SER) and which make it possible to cover the energy range and also associated electronic equipment. A brief description is first given of the physical processes involved: (n,p) collisions in the gas, influence of {gamma} radiation; the method of discrimination is then presented. It is based on the difference in the rise-times of the pulses. In the experiments described here the use of a bi-parametric system made it possible to employ the most simple discrimination device, based on the fact that the high frequency gamma pulse components are, at a given energy, weaker than those of the neutron pulses. Results are given of measurements carried out on the Van der Graaff (mono-energetic neutrons for testing the linearity of the chain and the resolving power of the counters), and of those made in a sub-critical system Hug at Cadarache. (author) [French] On decrit une chaine de spectrometrie travaillant dans le domaine d'energie de quelques keV a 1 MeV destinee a la mesure des spectres de neutrons rapides. Elle comprend les detecteurs, compteurs proportionnels a protons de recul, realises specialement pour cette etude par M. R. COMTE (DEG/SER), permettant de couvrir la gamme d'energie et l'electronique associee. Apres un rappel des processus physiques mis en jeu: chocs (n,p) dans les gaz, influence des rayonnements {gamma}, on expose la methode de discrimination utilisee. Celle-ci est basee sur la difference des temps de montee des impulsions. Au cours des experiences rapportees ici, la mise en oeuvre d'un ensemble bi-parametrique a permis d'utiliser le dispositif de discrimination le plus simple, base sur la remarque que les composantes a haute frequence des impulsions {gamma} sont, a

  19. Radiation-Induced Polymerization of Aldehydes and Ketones; Polymerisation radiochimique des aldehydes et des cetones; Radiatsionnaya polimerizatsiya al'degidov i ketonov; Polimerizacion radioinducida de aldehidos y cetonas

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, K.; Yamaoka, H.; Fujiwara, K.; Sakamoto, M.; Mori, S.; Natori, T.; Yoshida, H.; Okamura, S. [Japanese Association for Radiation Research on Polymers, Neyagawa Osaka (Japan); Kyoto University, Kyoto (Japan)

    1963-11-15

    Several kinds of aldehydes and ketones are polymerized by irradiation. Formaldehyde can be polymerized into high molecular weight polyoxymethylene by radiation-induced polymerization in the liquid phase at low temperatures. The polymerization mechanism is considered to be a cationic chain reaction both in the case of bulk and of solution in methylenechloride and toluene, but to be anionic in ethylether. Acetaldehyde and propionaldehyde are recognized as being hardly polymerized in the pure liquid phase, but easily polymerized in the presence of {gamma}-alumina. In the solid state polymerization, crystalline polymers are obtained as the stable- for- heat-treatment form under suitableconditions. Glyoxal can be polymerized into a three-dimensional network polymer. With formaldehyde it can be copolymerized into some cross-linked polyoxymethylene. Acetones such as chloroor bromoacetone and methylethylketone or diacetyl can be polymerized in the solid state into polymers which are unstable. Ketene can be polymerized into a polyester-type polymer with liquid phase polymerization; polyketone is obtained additionally when polymerization is carried out in the solid state. The copolymer with formaldehyde is slightly more stable. Dimethylketene can be easily polymerized both in the liquid and solid states into polyacetal. All these polymerizations are special examples of radiation-induced reactions and the reaction kinetics are interesting. Some details of this are discussed here. (author) [French] Plusieurs sortes d'aldehydes et de cetones se polymerisent sous l'effet des rayons gamma. L'aldehyde formique peut se transformer en polyoxymethylene de poids moleculaire eleve par polymerisation radiochimique en phase liquide a basses temperatures. On pense que la polymerisation est une reaction cationique en chaine lorsqu'il s'agit de masses ou de solutions dans du chlorure de methylene et du toluene, mais une reaction anionique en chaule dans une solution d'ether ethylique. L

  20. {beta} {gamma} porch detector; Detecteur portique {beta} {gamma}

    Energy Technology Data Exchange (ETDEWEB)

    Roulet, R [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1963-07-01

    This device is to be placed at the outside of reactors, hot laboratories and others where radioactive products are treated; it is intended to give the alarm when someone, passing through the porch is greatly contaminated, or carries, without his knowing, a radioactive substance. Being to be used in places where there might be an important ground noise, this device is provided with an automatic offset of this noise; an adjusting system of sensitivity allows to obtain a 15 {mu}Ci in {gamma} and 10 {mu}Ci in {beta} radioactive source, passing through the porch at the normal speed at which man is walking. A battery, set in buffer, allows working of the device, even when current is off. (author) [French] Cet appareil est destine a etre place a la sortie des reacteurs, laboratoires chauds ou autres laboratoires travaillant sur des produits radioactifs; son but est de donner une alarme lorsque quelqu'un, passant sous le portique, presente une forte contamination, ou surtout transporte par inadvertance un corps radioactif. Cet appareil devant etre utilise dans les lieux ou peut regner un bruit de fond important, possede une compensation automatique de ce bruit de fond; un reglage de la sensibilite permet d'obtenir au mieux un declenchement pour une source. de 15 {mu}Ci en {gamma} et 10 {mu}Ci en {beta} passant sous le portique a la vitesse normale d'un homme qui marche. Une batterie montee en tampon permet a l'appareil de fonctionner meme en cas de coupure de courant. (auteur)

  1. Study of {gamma} radiation from uranium rods during deactivation; Etude du rayonnement {gamma} des barres d'uranium en court de desactivation

    Energy Technology Data Exchange (ETDEWEB)

    Balestic, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1957-07-01

    The classical formulae giving the {gamma} activities of the fission products contained in a uranium rod after unloading from the pile are reviewed without being proved. The knowledge of these activities makes it possible, by means of the method proposed here, to determine the intensities of ionisation at a point outside the rod, and thus to establish {gamma} radiation diagrams. The different parameters introduced in the calculation are geometric (dimensions of the bars and coordinates of the point considered), energetic (power at which the bar has been irradiated) and temporal (duration of the irradiation and deactivation). A numerical example follows the demonstration of the general formulae, {gamma} flux measurements carried out in the deactivation well of P2 (Saclay pile) define the accuracy of the method. In conclusion, it is suggested that radiation diagrams be used in (planning the use of) industrial irradiators for radiochemical polymerisation or the preservation of food products. (author) [French] On rappelle sans demonstration les formules classiques donnant les activites {gamma} des produits de fission contenus dans une barre d'uranium apres defournement. La connaissance de ces activites permet par la methode proposee de passer aux intensites d'ionisation en un point exterieur a la barre et d'etablir ainsi des diagrammes de rayonnement {gamma}. Les differents parametres introduits dans le calcul sont d'ordre geometrique (dimensions des barres et coordonnees du point considere), d'ordre energetique (puissance a laquelle la barre a ete irradiee) et fonction du temps (duree d'irradiation et de desactivation). Un exemple numerique fait suite a la demonstration des formules generales. Des mesures de flux {gamma} effectuees au puits de desactivation de P2 (pile de Saclay) fixent le degre d'approximation de la methode. En conclusion, on suggere l'utilisation des diagrammes de rayonnement dans l'etablissement de projets d'irradiateurs industriels pour les

  2. Radiation therapy in old patients. Side effects and results of radiation therapy in old patients; Strahlentherapie des alten Patienten. Vertraeglichkeit und Ergebnisse der Strahlentherapie aelterer Personen

    Energy Technology Data Exchange (ETDEWEB)

    Geinitz, H.; Zimmermann, F.B.; Molls, M. [Klinik und Poliklinik fuer Strahlentherapie und Radiologische Onkologie, Klinikum rechts der Isar, Technische Univ. Muenchen (Germany)

    1999-03-01

    Background: Despite a growing number of elderly patients receiving radiation therapy little is known about side effects and outcome of irradiation in this section of the population. Methods: In a review article epidemiologic data, aspects of radiation-biology as well as side effects and outcome of radiation therapy of elderly patients are discussed. Results: Cancer incidence rises with age and is exceeding 3.5% for males older than 85 years. With a life expectancy of more than 4 years, curative therapy is indicated even at this age. Furthermore, several retrospective studies indicate that local control and disease-Specific survival after radiation therapy of elderly patients is comparable with that of younger persons. The exception contains elderly patients with grade-III to IV gliomas or with rectal carcinoma who show a reduced survival which is perhaps caused by less aggressive combined treatment (tumor resection). Although some biological and molecular data indicate a rise in radiation sensitivity with growing age like the reduction of the capacity of some DNA-repair enzymes, there is no convincing evidence in animal studies or in retrospective clinical studies that radiation therapy is generally less well tolerated by older individuals. Some age-depending differences in organ toxicities are described in 3 large studies, which evaluate the data of patients who were enrolled in different EORTC-trials: Older patients suffer more of functional mucositis in case of radiation therapy to the head and neck, they have an increased weight loss and a higher frequency of late esophageal damage when irradiated in the thorax, and they show a higher prevalence of sexual dysfunction when treated with radiation therapy to the pelvis. On the other hand younger patients suffer more from acute toxicity like skin damage, nausea, and deterioration of the performance status during pelvic radiotherapy. When discussing the dose intensity of radiation therapy concomitant disease which

  3. High-Dose Ionizing Radiation Photographic Dosimetry; Mesure, par des Methodes Photogra Phiques, de Doses Elevees de Rayonnements Ionisants; 0424 041e 0422 041e 0413 0420 0414 ; Dosimetria Fotografica de Dosis Elevadas de Radiaciones Ionizantes

    Energy Technology Data Exchange (ETDEWEB)

    Trousil, J.; Bucina, I. [Institute for Research Production and Application of Radioisotopes Prague, Czechoslovakia (Czech Republic)

    1965-06-15

    pour la detection de doses elevees de rayonnements et compare les merites respectifs des films FOMA et ORWO pour la mesure des doses elevees. Des progres ont egalement ete faits dans la mesure de doses elevees de rayonnements, a savoir la methode du developpement freine, decrite plus loin, dans laquelle des substances du type nitrobenzimidazole et benzotriazole sont utilisees a des concentrations appropriees dans le revelateur. Dans le cas d'emulsions lentes a forte teneur en argent, cette technique permet de mesurer des expositions a des doses gamma (rayons X de haute energie) allant jusqu'a 10s r ou meme davantage, si l 'on ne demande pas d'evaluations precises dans la gamme allant jusqu' a 100 r. Le memoire decrit l ' effet de freinage des produits chimiques ajoutes aux revelateurs sur les emulsions rapides et lentes a fortes teneur en argent. On a demontre que dans les emulsions utilisees pour la mesure de doses elevees de rayonnements intenses et traitees dans le revelateur auquel des produits chimiques de freinage ont ete ajoutes, les effets des variations en fonction de l'energie et l ' affaiblissement de l'image latente influent sur la precision des mesures. En conclusion, le memoire decrit les erreurs de dosimetrie photographique des rayonnements intenses qui ont ete decelees par des methodes statistiques mathematiques a partir de travaux experimentaux. Il est egalement question de l'accroissement de l'erreur dans les valeurs correspondant aux noircissements faibles et intenses. Les auteurs ont tenu compte egalement des erreurs dues a l'etalonnage des appareils, aux variations en fonction de l'energie, a l'affaiblissement de l'image latente, au traitement chimique et a la mesure du noircissement. La presomption que la dose mesuree par le detecteur a film correspond a la dose a l'organisme entier constitue une erreur qui n'est pas prise en consideration. (author) [Spanish] Los autores describen un metodo fotografico de medicion de dosis de radiaciones

  4. Radiation myelopathy. Analysis of the clinical picture. Die Strahlenmyelopathie. Klinische Analyse des Krankheitsbildes

    Energy Technology Data Exchange (ETDEWEB)

    Berlit, P

    1987-01-01

    After a review of the world literature, the case histories of 43 patients with radiation myelopathy are analyzed. In 1 patient there was a radiation injury of the medulla oblongata, in 2, cervical, in 28, thoracic, and in 12, lumbosacral. In the medulla oblongata lesion an alternans syndrome resulted. The patients with cervical and thoracic radiation myelopathies presented with a Brown-Sequard syndrome, a spinalis anterior syndrome or a transversal syndrome with pyramidal and spinothalamic tract involvement as the most prominent signs. For this group the term 'pyramidal-spinothalamic radiation myelopathy' is proposed. In lumbosacral radiation lesions a pure anterior horn syndrome may lead to spinothalamic tract involvement and the development of a cauda conus syndrome. The clinical presentation of these cases suggests that the location of the radiation lesion is most likely the region of the conus medullaris. The most frequent initial symptom was dysesthesia; the patients complained of burning pain or a feeling of coldness. Usually the neurological deficits were progressive, in pyramidal-spinothalamic radiation myelopathy over 12 months in average, in lumbosacral radiation lesions up to 10 years. The latent period between the finish of radiation therapy and the first neurological signs was 8 months (median) in cervical and thoracic myelopathy and 33 months in lumbosacral lesions. For the entire group of 43 patients there was an inverse relationship between the radiation dose (ret) and the latent period. A positive relation could be demonstrated between the age of patients at the time of radiation therapy and the latent period. Patients simultaneously receiving cytostatic drugs presented after a longer latent period than the remaining group. With 17 figs.

  5. Effects of Radiation on Germ Cells of Insects: Dominant Lethals, Gamete Inactivation and Gonial-Cell Killing; Effets des rayonnements sur les cellules germinales des insectes: letalite dominante, inactivation des gametes et destruction des cellules des gonades; Vozdejstvie radiatsii na polovye kletki nasekomykh: dominantnye letali, inaktivatsiya gamet i umershchvlenie polovykh kletok; Efectos de las radiaciones sobre las celulas germinales de los insectos: elementos letales dominantes, inactivacion de los gametos y exterminacion de las celulas gonadicas

    Energy Technology Data Exchange (ETDEWEB)

    Von Borstel, R. C. [Biology Division, Oak Ridge National Laboratory, Oak Ridge, TN (United States)

    1963-09-15

    Radiations and chemical mutagens kill cells in numerous ways: by one of several kinds of induced dominant lethality, by a direct inactivation of function as with sperm, and by genetically undefinable types of death which may or may not be related to dominant lethality per se. Also, chemical mutagens appear to exert a curious enhancement of the fertilizing capacity of sperm. The different stages of oflgenesis and spermatogenesis respond with unequal sensitivity to radiation, and individual cells pass through stages conferring as much as a 50-fold difference in sensitivity. Where species of Diptera, Hymenoptera and Coleoptera can be compared, a striking similarity of response to radiation can be observed, both to stage sensitivity and degree of response with dose. The silkworm, Bombyx mori (Lepidoptera), seems to be similar in most respects to representatives of the other orders in response of germ cells to radiation, but differs sharply in types of dominant lethality induced. Species having atypical genetic mechanisms (e.g.,the lecanoid system of Planococcus citri (Hemipt. : Coccidae) are special cases, and their responses to radiation are considerably modified from those of other species. For insect population control by the irradiation-of-male method, dominant lethality is as advantageous in species where matings are multiple as in species where mating occurs once. Sperm inactivation and gonial killing can be regarded as instances of true sterility and are maximally effective only in species where mating occurs once. For most efficient control, doses should be chosen which would induce maximum dominant lethality, minimum sperm inactivation and complete killing of gonial cells. These parameters are simple to determine by gamete viability measurements, irradiated and unirradiated population competition experiments and histological examination of gonia. (author) [French] Les rayonnements et les agents chimiques de mutation detruisent les cellules de nombreuses facons

  6. A study of some radioprotection apparatuses used in the case of pool reactors; Etude de quelques dispositifs de radioprotection en service aupres des piles piscines

    Energy Technology Data Exchange (ETDEWEB)

    Robien, E de; Choudens, H de; Delpuech, J [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1965-07-01

    Various problems of radioprotection concerning swimming-pool reactors in Grenoble have led us to study adequate solutions: a) The automatic verification of the staff-radioactivity when coming out of Melusine or Siloe has been realized thanks to a {beta}{gamma} gate which is insensitive to the ambient background in the reactor-hall; b) The automatic verification of the contamination of the shoes of the agents working in these reactors has been realized with a dedicated device; c) The necessity to measure precisely {gamma} doses with the help of an autonomous apparatus has led to the making of a plastic-scintillator {gamma} dosimeter; d) The obligation to forbid the opening of doors in some places where there might be a great intensity of radiation, has led us to make doors open according to the intensity of radiation inside the rooms; e) The releases of radioactive iodine have been measured with activated charcoal cartridges that surround a scintillator connected with a unique channel selector; f) Finally the control of reactor safety rod fall in case of a radioactive accident has been secured by a chain whose detector is a chamber immersed in the swimming-pool, which offers, in the particular case of the hot thickness swimming-pool reactor a double advantage: first it enables us to regulate the upper hot water layer, second to get free of transitory radiations which appear in the reactor hall as the experimental apparatuses are taken out from the core. (authors) [French] Differents problemes de radioprotection se posant aupres des piles piscines de Grenoble, ils ont necessite l'etude de solutions particulieres: a) le controle automatique de la radioactivite du personnel sortant de Melusine ou de Siloe a ete realise a l'aide d'un portique {beta}{gamma} insensible au bruit de fond ambiant du hall des piles; b) le controle automatique de la contamination des souliers des agents travaillant dans ces piles a ete realise par une passerelle pieds {beta}{gamma}; c) la

  7. Second meeting of competent persons in radiation protection; Deuxiemes rencontres des personnes competentes en radioprotection

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    This conference treats the subjects interesting the competent persons in radiation protection. It is divided in four sessions. The first one concerns the regulatory bases for the action of competent persons and includes three articles, the second one is about the operational dosimetry and includes six articles, the third session is devoted to the sources and waste management and represents two texts, the last and fourth session concerns the competent person in radiation protection and gives evidence. (N.C.)

  8. The radiation effects on the living cell; Les effets des rayonnements sur la cellule vivante

    Energy Technology Data Exchange (ETDEWEB)

    Sage, E; Dutrillaux, B; Soussi, Th [Institut Curie, 75 - Paris (France); [Centre National de la Recherche Scientifique (CNRS), 75 - Paris (France); Boiteux, S; Lopez, B [CEA-CNRS/Fontenay-aux-Roses, 92 (France); Feunteun, J [Institut Gustave Roussy, 94 - Villejuif (France)

    1999-06-01

    This publication is a presentation of particular points discussed during the colloquium of the 15-18 june 1999, for which scientific researches are performed at the CEA/CNRS. They deal with the radiobiology, for the radiation effects on living matter; with the DNA, for the knowledge and repair mechanisms on cells submitted to ionizing radiations; with the exposition to UV in correlation with neoplasms; with the P53 gene which is a tumour suppressor. (A.L.B.)

  9. Determination and stabilization of the altitude of an aircraft in space using semi-conductor detectors; Determination et stabilisation de l'altitude d'un aeronef par detecteur a semiconducteur

    Energy Technology Data Exchange (ETDEWEB)

    Gilly, L. [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1967-07-01

    The device studied in this report can be used as altimeter or as altitude stabilizer (B.F. number PV 100-107, March 23, 1967). It includes essentially a 'surface barrier' semiconductor detector which counts alpha particles of a radioactive source. Two sources are used corresponding to two possible utilizations of the device. This report describes experiences made in laboratory which comprises electronic tests and a physic study. Systematic analysis of experimental errors is made comparatively with aneroid altimeters. An industrial device project is given. (author) [French] L'appareil etudie dans ce rapport peut etre utilise soit en altimetre, soit en stabilisateur d'altitude (B.F. numero PV 100-107, 23 mars 1967). Il comprend essentiellement un detecteur semiconducteur du type 'barriere de surface' qui compte les particules alpha d'une source radioactive. Deux sources sont utilisees correspondant aux deux utilisations possibles de l'appareil. Ce rapport decrit les experiences realisees en laboratoire, qui comprennent des tests electroniques et une etude physique. L'analyse systematique des diverses erreurs experimentales est faite, en comparaison avec les altimetres du type 'aneroide'. Un projet d'appareil est donne. (auteur)

  10. Determination and stabilization of the altitude of an aircraft in space using semi-conductor detectors; Determination et stabilisation de l'altitude d'un aeronef par detecteur a semiconducteur

    Energy Technology Data Exchange (ETDEWEB)

    Gilly, L [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1967-07-01

    The device studied in this report can be used as altimeter or as altitude stabilizer (B.F. number PV 100-107, March 23, 1967). It includes essentially a 'surface barrier' semiconductor detector which counts alpha particles of a radioactive source. Two sources are used corresponding to two possible utilizations of the device. This report describes experiences made in laboratory which comprises electronic tests and a physic study. Systematic analysis of experimental errors is made comparatively with aneroid altimeters. An industrial device project is given. (author) [French] L'appareil etudie dans ce rapport peut etre utilise soit en altimetre, soit en stabilisateur d'altitude (B.F. numero PV 100-107, 23 mars 1967). Il comprend essentiellement un detecteur semiconducteur du type 'barriere de surface' qui compte les particules alpha d'une source radioactive. Deux sources sont utilisees correspondant aux deux utilisations possibles de l'appareil. Ce rapport decrit les experiences realisees en laboratoire, qui comprennent des tests electroniques et une etude physique. L'analyse systematique des diverses erreurs experimentales est faite, en comparaison avec les altimetres du type 'aneroide'. Un projet d'appareil est donne. (auteur)

  11. Evaluation of Dose: Comparative Effect of Fast Neutrons and other Types of Radiation on the Survival of E. Coli and S. Cerevisiae; Evaluation de la Dose Delivree et Actions Comparees des Neutrons Rapides et d'Autres Radiations sur la Survie de E. Coli et S. Cerevisiae; Otsenka dozy i sravnitel'noe vliyanie bystrykh nejtronov i drugikh vidov izlucheniya na vyzhivaemost' E. Coli i S. Cerevisiae; Evaluacion de la Dosis Suministrada y Comparacion de la Accion de los Neutrones Rapidos sobre la Supervivencia del E. Coli y del S. Cerevisiae con la de Otras Radiaciones

    Energy Technology Data Exchange (ETDEWEB)

    Arnaud, Y.; Bocquet, C. [Centre d' Etudes Nucleaires de Saclay (France)

    1964-05-15

    The EL-3 reactor is equipped with auranium converter by means of which fast neutrons can be obtained. A bank of fission chambers measures the flux and spectral distribution of the fast neutrons. These miniature detectors are placed at various points in the target zone and make possible the experimental evaluation of the absorbed tissue-dose. This apparatus and dosimetric technique can be used to compare the effect of fast neutrons and other types of ionizing radiation (e.g. X-rays) on unicellular organisms. The authors study the percentage of survivals and the frequency of a mutation in Saccharomyces cerevisiae. The survival curve for Escherichia coli is also determined for X-rays and neutrons. It is found that the RBE's of these various types of radiation depend not only on the species and the biological criterion adopted, but also on the irradiation dose-level at which the comparison is made. These experiments show the RBE to be also a function of dose. The effects of fast neutrons and X-rays are often brought about by differing radiobiological processes. It is arbitrary to establish linear relationships between the doses for these various types of radiation. (author) [French] Nous disposons aupres du reacteur EL3 d'un convertisseur a uranium permettant d'obtenir des neutrons rapides. Une batterie de chambres a fission mesure le flux et la repartition spectrale des neutrons rapides. Ces detecteurs miniatures sont places en divers points du volume a irradier et permettent d'evaluer experimentalement la dose absorbee dans les tissus. Ce dispositif et cette dosimetrie nous servent a comparer l'action des neutrons rapides et d'autres radiations ionisantes (X, {gamma}) sur des organismes monocellulaires. Nous etudions ici le pourcentage de survie et la frequence d'une mutation morphologique chez Saccharomyces cerevisiae. La courbe de survie d'Escherichia coli est aussi etablie pour les rayons X et les neutrons. On observe que les effets biologiques relatifs de ces

  12. Development of ultracold neutron detectors and a polarization analyzing system for the measurement of the neutron electric dipole moment; Developpement de detecteurs de neutrons ultra-froids et d'un systeme d'analyse de polarisation pour la mesure du moment electrique dipolaire du neutron

    Energy Technology Data Exchange (ETDEWEB)

    Rogel, Gwendal

    2009-10-29

    This thesis was performed in the context of a project aiming to measure the electric dipole moment (EDM) of the neutron at the Paul Scherrer Institute. Two aspects have been studied: The detection and the polarization analysis of ultracold neutrons. Three types of detectors have been tested at the Institut Laue-Langevin (ILL): The Cascade-U (GEM technology), the {sup 3}He gas detector and {sup 6}Li-doped glass scintillators (GS family). Their detection efficiency and their background sensitivity have been measured. The GS10 scintillator is competitive with the {sup 3}He gas detector under the conditions realized with the EDM spectrometer. A GS3/GS20 scintillator stack has enabled to improve the neutron/gamma discrimination. It has been found 20% less efficient than the {sup 3}He gas detector under the EDM spectrometer. The Cascade-U detector has been observed to be 20% less efficient than a 500 microns thick GS10 glass as confirmed by simulations. A new system for simultaneous spin analysis is presented. It consists of two independent detection systems (arms) which are each made of an adiabatic spin flipper, a spin analyzer, and a detector. The arms detect opposite spin components, allowing the simultaneous counting of both neutron spin orientations. A prototype mounted in horizontal configuration has been tested at ILL. The analyzing power of both arms has been measured to be 80%. The transmission of the system without spin analyzers has been found to be 50%. (author) [French] Cette these s'inscrit dans un nouveau projet de mesure du moment dipolaire electrique (EDM) du neutron a l'institut Paul Scherrer. Deux aspects ont ete etudies ici: la detection et l'analyse de polarisation de neutrons ultra-froids. Trois types de detecteurs ont ete testes a l'Institut Laue-Langevin (ILL): le Cascade-U (technologie GEM), le compteur a gaz {sup 3}He et des scintillateurs dopes au {sup 6}Li (type GS). Leur efficacite de detection ainsi que leur sensibilite au bruit de fond ont

  13. Consequences of the new radiation protection law on the radiation protection register and the occupational radiation protection; Auswirkungen des neuen Strahlenschutzgesetzes auf das Strahlenschutzregister und die berufliche Strahlenueberwachung

    Energy Technology Data Exchange (ETDEWEB)

    Frasch, Gerhard

    2017-08-01

    The implementation of the guideline 2013/59/EURATOM has been performed in the new radiation protection law. The most important consequences of the new radiation protection law for the occupational radiation protection are the following: the introduction of an explicit personal indicator and the actualization of occupational categories for employees. These facts require technical and administrative reorganization in data transmission of the licensee to the regulatory monitoring executive and the radiation protection register.

  14. The new radiation protection ordinance from the viewpoint of the researcher in nuclear medicine; Die neue Strahlenschutzverordnung aus der Sicht des in der Forschung taetigen Nuklearmediziners

    Energy Technology Data Exchange (ETDEWEB)

    Reiners, Chr.; Lassmann, M. [Klinik und Poliklinik fuer Nuklearmedizin der Univ. Wuerzburg (Germany)

    2002-05-01

    After the new radiation protection ordinance has come into effect with July 20th, 2001 the approval process for application of radiation substances or ionizing radiation in medical research changed considerably with respect to the responsibility of the Federal Office for Radiation Protection as the approval authority, the participation of an approved ethic committee, the inclusion of an expert for medical physics for planning and execution of the study as well as stricter regulations for cover clause. On the contrary, existing regulations have been facilitated since the effective dose limit for volunteers has been increased from 10 to 20 mSv and a central procedure for approval of multicenter studies has been introduced. Moreover, the application of radioactive substances or ionizing radiation for research in people without or with restricted legal capacity is no more totally prohibited. At present, changes of the radiation protection ordinance and the atomic law cover clause ordinance with respect to medical research are in discussion. (orig.) [German] Nach In-Kraft-Treten der neuen Strahlenschutzverordnung vom 20.07.2001 ergeben sich wesentliche Aenderungen des Genehmigungsverfahrens fuer die Anwendung radioaktiver Stoffe oder ionisierender Strahlung in der medizinischen Forschung bezueglich der Zustaendligkeit des Bundesamts fuer Strahlenschutz als Genehmigungsbehoerde, der Einschaltung einer akkreditierten Ethikkommission, der Hinzuziehung eines Medizinphysik-Experten bei der Studien-Planung und -Anwendung sowie verschaerfter Regelungen zur Deckungsvorsorge. Eine gewisse Erleichterung bisher bestehender Regelungen ist in der Erhoehung des Grenzwerts der effektiven Dosis fuer Probanden von 10 auf 20 mSv sowie dem zentralen Genehmigungsverfahren fuer Multizenter-Studien zu sehen. Ausserdem ist eine Anwendung radioaktiver Stoffe oder ionisierender Strahlung in der Forschung an geschaeftsunfaehigen und beschraenkt geschaeftsfaehigen Probanden nicht mehr voellig

  15. The radiation protection and the radioactive wastes management; La radioprotection et la gestion des dechets radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    Servais, F. [CHR Hopital de Warquignies, Service de Medecine Nucleaire (Belgium); Woiche, Ch. [Universite Libre de Bruxelles, Service Interne et de Prevention et Protection (Belgium); Hunin, Ch. [Agence Federale de Controle Nucleaire, Service Controle Etablissements Classes, Brexelles (Belgium)] [and others

    2003-07-01

    This chapter concerns the radiation protection in relation with the radioactive waste management. Three articles make the matter of this file, the management of radioactive medical waste into hospitals, a new concept of waste storage on site, the protection devices on the long term with some lessons for the radioactive waste management. (N.C.)

  16. Seventh meeting of radiation protection skilled persons; Septiemes rencontres des personnes competentes en radioprotection

    Energy Technology Data Exchange (ETDEWEB)

    Juhel, Th.; Briandchamplong, J.; Gambini, D.J.; Ammerich, M.; Aubert, B.; Barbey, P.; Biau, A.; Bruchet, H.; Capelle, M.H.; Flon, E.; Gauron, Ch.; Gravelotte, D.; Guerin, Ch.; Le Denmat, D.; Lemoine, Th.; Lombard, J.; Lucas, St.; Menechal, Ph.; Mignien, S.; Million, M.; Mozziconacci, J.G.; Prevot, S.; Radecki, J.J.; Rigaud, S.; Taillandier, P.; Timbert, M.; Vidal, J.P.; Bardelay, Ch.; Lahaye, Th.; Balduyck, S.; Chasson, E.; Rehel, J.L.; Chatellier, Ch.; Barret, Ch.; Guersen, J.; Degrange, J.P.; Sevestre, B.; Lahaye, Th.; Rodde, S.; Marchal, C.; Lefaure, Ch.; Bouk' il, H.; Gneiting, M.; Auboiroux, B.; Riedel, A.; Feuardent, J.; Scanff, P.; Bof, M.; Lochard, J.; Godet, J.L.

    2011-07-01

    This document gathers the slides of the available presentations given during these conference days. Twenty-three presentations out of 25 are assembled in the document and deal with: 1 - the evolution of workers' international protection rules against ionizing radiation risks (C. Bardelay); 2 - presentation of the report of the working group on radiation protection (P. Barbey); 3 - position of the French nuclear safety authority and of the labor general direction about the position of permanent expert groups in radiation protection concerning the expected evolutions in the occupation and training of radioprotection skilled persons (RSP), (T. Lahaye); 4 - experience feedback: RSP in surgery operating theater - a sometimes delicate intervention (S. Balduyck); 5 - workplace analysis in dental surgery: constraints and specificities (D. Le Denmat); 6 - workplace analysis: tritium atmospheric contamination (S. Rigaud); 7 - revision of the NFC 15-160 standard relative to radiology facilities (J.L. Rehel); 8 - example of area tele-dosimetry usage - the Pitie Salpetriere hospital experiment (C. Chatellier and C. Barret); 9 - contribution of radio-attenuation lead gloves in interventional radiology (J. Guersen); 10 - zoning in the medical domain: encountered problems typology and evaluation of possible solutions (Degrange, J.P.); 11 - management of used sealed sources distributed by the CEA and CISBIO (B. Sevestre); 12 - how to perform a measurement in radiation protection - how about measurement uncertainty (M. Ammerich); 13 - national campaign of control about the application of workers radiation protection rules (T. Lahaye); 14 - transparency and inspection approach in local nuclear applications: gamma-graphy, research, nuclear medicine, interventional radiography and radiotherapy (S. Rodde and C. Marchal); 15 - local/regional networks of RSPs and radiation protection actors: 2008 audit results and recent evolutions (C. Lefaure); 16 - role and missions of the external

  17. Apparatus for studying the diffusion of rare gases in stainless steel; Appareil pour etude de la diffusion des gaz rares dans l'acier inoxydable

    Energy Technology Data Exchange (ETDEWEB)

    Stohr, J A; Alfille, L [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    This apparatus enables measurements to be carried out on the diffusion of gaseous fission products and of gases in general across thin metallic walls at high temperatures. This work was initially intended to solve the problems involved in systems for detecting the rupture of a fuel element can (D.R.G.) by the diffusion of fission products through the cans at high temperatures. The extension of the work to other fields is envisaged. (author) [French] Cet appareil permet d'effectuer des mesures sur la diffusion des produits de fission gazeux, et des gaz en general, au travers de parois metalliques minces a haute temperature. Au depart, ce procede devait contribuer a resoudre les problemes poses aux systemes detecteurs de rupture de gaine (D.R.G.), par la diffusion des produits de fission au travers des gaines de cartouches a haute temperature. Son extension a d'autres etudes est envisagee. (auteur)

  18. Nuclear safety and radiation protection report of the Saint-Laurent-Des-Eaux nuclear facilities - 2014

    International Nuclear Information System (INIS)

    2015-01-01

    This safety report was established in accordance with articles L. 125-15 and L. 125-16 of the French environmental code. It presents, first, the NPPs (INBs no. 46, 74 and 100). Then, the nuclear safety and radiation protection measures taken regarding the facilities are reviewed: nuclear safety definition, radiation protection of intervening parties, safety and radiation protection improvement paths, crisis management, external and internal controls, technical situation of facilities, administrative procedures carried out in 2014. The incidents and accidents which occurred in 2014, if any, are reported as well as the radioactive and non-radioactive effluents discharge in the environment. Finally, the radioactive materials and wastes generated by the facility are presented (type of waste, quantities, conditioning process) as well as the other pollutions. The document concludes with a presentation of the actions of communication and public information made by the direction of the facility. A glossary and the list of recommendations from the Committees for health, safety and working conditions are given in appendix

  19. Fifth meeting of persons competent in radiation protection; Cinquiemes rencontres des personnes competentes en radioprotection

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-01

    During this meeting will successively be approached: the statutory frame, the practical guide for the realization of the dosimetry studies of work stations presenting a risk of exposure to ionizing radiations, a study of post in conventional and interventional radiology, study of post in interventional cardiology, the roles and the missions of the P.C.R. (person competent in radiation protection) in a subcontractor company in I.N.B. (base nuclear installation), the application of the zoning order for the activities of industrial radiography, the evolution of the statutory measures in protection of the workers against the dangers of ionizing radiations, all which concerns the P.C.R. (training, missions, certification, educational role), the controls of radioprotection, the external controls of radioprotection, the surveillance of working zones, surveillance of effluents,management of the radioactive waste and effluents, classification of the personnel and the surveillance of the exposure, dosimetry by radio photo luminescence, the systeme S.I.S.E.R.I.. (N.C.)

  20. Nuclear safety and radiation protection report of the Saint-Laurent-Des-Eaux nuclear facilities - 2012

    International Nuclear Information System (INIS)

    2013-01-01

    This safety report was established in accordance with articles L. 125-15 and L. 125-16 of the French environmental code. It presents, first, the NPPs (INBs no. 46, 74 and 100). Then, the nuclear safety and radiation protection measures taken regarding the facilities are reviewed: nuclear safety definition, radiation protection of intervening parties, safety and radiation protection improvement paths, crisis management, external and internal controls, technical situation of facilities, administrative procedures carried out in 2012. The incidents and accidents which occurred in 2012, if any, are reported as well as the radioactive and non-radioactive effluents discharge in the environment. Finally, the radioactive materials and wastes generated by the facility are presented (type of waste, quantities, conditioning process) as well as the other pollutions. The document concludes with a presentation of the actions of communication and public information made by the direction of the facility. A glossary and the list of recommendations from the Committees for health, safety and working conditions are given in appendix. (J.S.)

  1. Nuclear safety and radiation protection report of the Saint-Laurent-Des-Eaux nuclear facilities - 2013

    International Nuclear Information System (INIS)

    2014-01-01

    This safety report was established in accordance with articles L. 125-15 and L. 125-16 of the French environmental code. It presents, first, the NPPs (INBs no. 46, 74 and 100). Then, the nuclear safety and radiation protection measures taken regarding the facilities are reviewed: nuclear safety definition, radiation protection of intervening parties, safety and radiation protection improvement paths, crisis management, external and internal controls, technical situation of facilities, administrative procedures carried out in 2013. The incidents and accidents which occurred in 2013, if any, are reported as well as the radioactive and non-radioactive effluents discharge in the environment. Finally, the radioactive materials and wastes generated by the facility are presented (type of waste, quantities, conditioning process) as well as the other pollutions. The document concludes with a presentation of the actions of communication and public information made by the direction of the facility. A glossary and the list of recommendations from the Committees for health, safety and working conditions are given in appendix

  2. The workers and public radiation protection; La radioprotection des travailleurs et du public

    Energy Technology Data Exchange (ETDEWEB)

    Le Guen, B. [Electricite de France (EDF), Lab. d' Analyses Medicales et de Radiotoxicologie, SCAST, 93 - Saint-Denis (France); Roupioz, A. [Electricite de France (EDF Industrie), DPN, 93 - Saint-Denis (France); Rabu, B. [CEA Cadarache, Lab. de Transfert de Contamination, 13 - Saint Paul lez Durance (France)] [and others

    2003-07-01

    Six texts develop the question of the radiation protection of workers and public. Monitoring of the exposure risk to alpha emitters during the unit outage of nuclear power plant of Cattenom is the first one, the second article concerns the ALARA approach applied to the yard that controls the welding of vapor generators of the Phenix reactor. The third one treats the evaluation of impact in environment of tritium releases associated to a fusion reactor accident. Some systems of radiological detection are studied, the notion of dose constraint is discussed, and what about the cooperation around nuclear and non nuclear installations. (N.C.)

  3. The study and the realization of radiation detectors made from polycrystalline diamond films grown by microwave plasma enhanced chemical vapour deposition technique; Etude et realisation de detecteurs de rayonnements a base de films de diamant polycristallin elabores par depot chimique en phase vapeur assiste par plasma micro-onde

    Energy Technology Data Exchange (ETDEWEB)

    Jany, Ch

    1998-10-29

    The aim of this work was to develop radiation detectors made from polycrystalline diamond films grown by microwave plasma enhanced chemical vapour deposition technique. The influence of surface treatments, contact technology and diamond growth parameters on the diamond detectors characteristics was investigated in order to optimise the detector response to alpha particles. The first part of the study focused on the electrical behaviour of as-deposited diamond surface, showing a p type conduction and its influence on the leakage current of the device. A surface preparation process was established in order to reduce the leakage current of the device by surface dehydrogenation using an oxidising step. Several methods to form and treat electrical contacts were also investigated showing that the collection efficiency of the device decreases after contact annealing. In the second part, we reported the influence of the diamond deposition parameters on the characteristics of the detectors. The increase of the deposition temperature and/or methane concentration was shown to lead {eta} to decrease. In contrast, {eta} was found to increase with the micro-wave power. The evolution of the diamond detector characteristics results from the variation in sp{sup 2} phases incorporation and in the crystallography quality of the films. These defects increase the leakage current and reduce the carrier mobility and lifetime. Measurements carried out on detectors with different thicknesses showed that the physical properties varies along the growth direction, improving with the film thickness. Finally, the addition of nitrogen (> 10 ppm) in the gas mixture during diamond deposition was found to strongly reduce the collection efficiency of the detectors. To conclude the study, we fabricated and characterised diamond devices which were used for thermal neutron detection and for the intensity and shape measurement of VUV and soft X-ray pulses. (author)

  4. Fourth meeting of persons competent in radiation protection; Quatriemes rencontres des personnes competentes en radioprotection

    Energy Technology Data Exchange (ETDEWEB)

    David, C. [Centre Hospitalier de Belfort-Montbeliard, 90 (France); Vidal, J.P.; Ammerich, M.; Feron, F. [Drection Generale de la Surete Nucleaire et de la Radioprotection, 75 - Paris (France); Pasquier, J.L.; Lecomte, J.F.; Mansoux, H. [Institut de Radioprotection et de Surete Nucleaire, 92 - Clamart (France); Menechal, Ph. [Societe Francaise de Radioprotection, 92 - Fontenay aux Roses (France); Briand-Champlong, J. [Service de protection radiologique (SPRA), 75 - Paris (France); Gambini, D.J. [Paris-5 Univ., 75 (France); Bontemps, A. [CEFRI, 92 - Paris La Defense (France); Frobert, F. [CEA Saclay, Institut National des Sciences et Techniques Nucleaires, 91 - Gif-sur-Yvette (France); Grandclaude, A. [Societe Cursive (France); Fraboulet, P. [Groupe Hospitalier la Pitie-Salpetriere, - 75 Paris (France); Laporte, Ch. [FRAMATOME ANP, 92 - Paris-La-Defence (France); Roussille, F. [INSERM, 75 - Paris (France); Lahaye, Th

    2005-07-01

    The different contributions are as follow: the landscape of radiation sources in France; decrees: general presentation; relation of the person competent in radiation protection (P.C.R.) with officials organisms: the part of the D.G.S.N.R.; relation of the P.C.R. with the official organisms: the part of I.R.S.N.; authorizations: industry, education, research; interlocutors of the P.C.R. in hospitals; enforcement of the decree relative to the training of the P.C.R. at the I.N.S.T.N.; the educational contribution of the P.C.R.; European equivalence of the P.C.R. synthesis of training, comparison to the French situation; P.C.R.: contribution, missions and means in the industrial medium; management of damaged situations by the P.C.R.: contribution of the training and the putting in position; coordination with the exterior companies and prevention plans out of I.N.B.; regulatory evolution. (N.C.)

  5. Radiation therapy for leukemias and lymphomas in childhood; Radiotherapie des hemopathies malignes de l`enfant

    Energy Technology Data Exchange (ETDEWEB)

    Levy-Piedbois, C.; Habrand, J.L. [Institut Gustave Roussy, 94 - Villejuif (France)

    1999-03-01

    Children treated for malignant hemopathy have a very good prognosis, yet late effects of the treatments on the length, endocrine function, cognitive function and the risk of secondary malignant tumors must be decreased. These toxicities are described in this article. New protocols and radiation techniques have been developed to reduce these effects. Radiotherapy is prescribed in the treatment of non-Hodgkin lymphoma to prevent high risk of meninges recurrences or to treat meninges disease associated with chemotherapy. Doses of cranial irradiation are limited to 24 Gy. A SFOP trial concluded that does of 20 Gy are sufficient after good responses to chemotherapy for the treatment of Hodgkin`s disease. The target volume is reduced to the initial site of the disease. (author)

  6. Effects of low doses of ionizing radiation; Effets des faibles doses de rayonnements ionisants

    Energy Technology Data Exchange (ETDEWEB)

    Masse, R. [Office de Protection contre les Rayonnements Ionisants, 78 - le Vesinet (France)

    2006-07-01

    Several groups of human have been irradiated by accidental or medical exposure, if no gene defect has been associated to these exposures, some radioinduced cancers interesting several organs are observed among persons exposed over 100 to 200 mSv delivered at high dose rate. Numerous steps are now identified between the initial energy deposit in tissue and the aberrations of cell that lead to tumors but the sequence of events and the specific character of some of them are the subject of controversy. The stake of this controversy is the risk assessment. From the hypothesis called linear relationship without threshold is developed an approach that leads to predict cancers at any tiny dose without real scientific foundation. The nature and the intensity of biological effects depend on the quantity of energy absorbed in tissue and the modality of its distribution in space and time. The probability to reach a target (a gene) associated to the cancerating of tissue is directly proportional to the dose without any other threshold than the quantity of energy necessary to the effect, its probability of effect can be a more complex function and depends on the quality of the damage produced as well as the ability of the cell to repair the damage. These two parameters are influenced by the concentration of initial injuries in the target so by the quality of radiation and by the dose rate. The mechanisms of defence explain the low efficiency of radiation as carcinogen and then the linearity of effects in the area of low doses is certainly the least defensible scientific hypothesis for the prediction of the risks. (N.C.)

  7. About the problem of the delays between particles belonging to the cosmic radiation; Sur le probleme des retards entre des particules appartenant au rayonnement cosmique

    Energy Technology Data Exchange (ETDEWEB)

    Rogozinski, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1953-07-01

    After having examined briefly the problem of the delays who can appear between particles of high energy, issued of a same mother particle, we studied in a more details the case of the loaded particles, loosing their energy by ionization. The delay that settles between two particles of mass M belonging to this last species is defined by the difference between the times that they take to do the same distance. In the vacuum, the delays can reach any values. But, when the particles diffuse themselves in a middle absorbing, the delays stretch toward a definite limit whatever the initial energies of the particles is. One demonstrates that the maximum delay is given by ({delta}t){sub max} {approx_equal} 0,6 E{sub 0} / cK{sub min}, where E{sub 0} = Mc{sup 2} represents the energy to the rest of the particle and K{sub min} the minimum loss of energy by cm of course in the given middle. For example, in the case of the protons crossing different absorbing surroundings, the values of ({delta}t){sub max} for air (Tpn), water, the Al and the Pb are respectively equal to 8,3.10{sup -6}, 9,7.10{sup -9}, 45.10{sup -9} and 1,6 10{sup -9} dry. The corresponding values of ({delta}t){sub max} for the electrons, are the order of 10{sup -9} dry for air and the order of 10{sup -12} dry for the condensed surroundings. It results that, if the particles belonging has a sheaf demonstrated between them of the superior delays to those that are indicate, the fact would constitute a sufficient proof of the existence of heavy particles to the breast of the sheaf. Otherwise, the relation that joins ({delta}t){sub max} to the mass M could act as basis to a method of mass spectrography of the big energy particles. (author) [French] Apres avoir examine succintement le probleme des retards qui peuvent apparaitre entre des particules de grande energie, issues d'une meme particule mere, on etudie d'une facon plus detaillee le cas des particules chargees, ne perdant leur energie que par ionisation. Le

  8. Natural and anthropogenic radiation exposure of humans in Germany; Natuerliche und zivilisatorische Strahlenexposition des Menschen in Deutschland

    Energy Technology Data Exchange (ETDEWEB)

    Koelzer, Winfried

    2016-12-15

    The contribution on natural and anthropogenic radiation exposure in Germany covers the following issues: (1) natural radiation exposure: external radiation exposure - cosmic and terrestric radiation, internal radiation exposure - primordial and cosmogenic radionuclides; radiation exposure due to sola neutrinos and geo-neutrinos. (2) Anthropogenic radiation exposure: radiation exposure in medicine, radioactivity in industrial products, radiation exposure during flights, radiation exposure due to nuclear facilities, radiation exposure due to fossil energy carriers in power generation, radiation exposure due to nuclear explosions, radiation exposure due to nuclear accidents. (3) Occupational radiation exposure in Germany: radiation monitoring with personal dosimeters in medicine and industry, dose surveillance of the aviation personal, working places with increases radiation exposure by natural radiation sources.

  9. Burnup determination of power reactor fuel elements by gamma spectrometry; Determination par spectrometrie {gamma} du taux d'irradiation des elements combustibles des reacteurs de puissance

    Energy Technology Data Exchange (ETDEWEB)

    Robin, M; Jastrzeb, M; Boisliveau, S; Boyer, R; Vidal, R [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1969-07-01

    This report describes a method for determining by {gamma} spectrometry the burn up and the specific power of fuel elements irradiated in power reactors. The energy spectrum of {gamma} rays emitted by fission products is measured by means of a simple equipment using a sodium iodide detector and a multichannel analyzer. In order to extract from the spectrum a quantity proportional to the burn up, it is necessary to: - isolate an activity specific of one emitter,- give the same importance to fissions in uranium and plutonium - take into account the radioactive decay during and after irradiation. One hundred fuel elements were studied and burn up values obtained by {gamma} spectrometry are compared to results given by chemical analyses. Preliminary measurements show that the accuracy of the results is greatly increased by the use of a germanium detector, due to its good resolution. (authors) [French] Ce rapport expose une methode de determination par spectrometrie {gamma} du taux d'irradiation et de la puissance specifique des elements combustibles irradies dans les reacteurs de puissance. Une installation simple utilisant un detecteur d'iodure de sodium et un selecteur multicanaux mesure le spectre en energie du rayonnement {gamma} emis par les produits de fission. Afin d'extraire du spectre une quantite proportionnelle au taux de combustion, il faut: - isoler une activite specifique a un emetteur, - donner la meme importance aux fissions survenues dans l'uranium et le plutonium, - prendre en compte la decroissance radioactive pendant et apres l'irradiation. Les mesures ont porte sur une centaine d'elements combustibles et les taux de combustion obtenus par spectrometrie {gamma} sont compares aux resultats des analyses chimiques. Des mesures preliminaires montrent que l'utilisation d'un detecteur de germanium augmente considerablement la precision des resultats, en raison de son excellente resolution. (auteurs)

  10. Gamma radiation in space and in the atmosphere; Rayonnement gamma dans l'espace et dans l'atmosphere

    Energy Technology Data Exchange (ETDEWEB)

    Rocchia, R. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1966-07-01

    We have shown that the {gamma} radiation existing in the atmosphere is caused mainly by the Bremsstrahlung of the electrons of the electromagnetic cascades ({approx} 50 per cent of the measured radiation), by the 511 keV radiation produced by the annihilation of positrons created in cascades (8 per cent of the measured intensity) and by the Compton {gamma} degradation of this line (30 per cent of the measured intensity). The rest, slightly over 10 per cent, must be attributed to secondary causes such as the nuclear de-excitation {gamma} to the internal Bremsstrahlung of charged particles created in nuclear stars, and to charged particles crossing our detector, since the latter was not fitted with a device for rejecting these particles. Experiments carried out in rockets at Colomb-Bechar confirm these results and have made it possible to detect and measure a primary {gamma} radiation having an intensity of {approx} 2 {gamma} cm{sup 2} s{sup -1} above 100 keV. The primary spectrum obeys an approximate E{sup -2} law. (author) [French] Nous avons montre que le rayonnement {gamma} existant dans l'atmosphere est provoque principalement por le bremsstrohlung des electrons des cascades electromagnetiques ({approx} 50 pour cent du rayonnement mesure), au rayonnement 511 keV provoque par l'annihilation des positrons crees dans les cascades (8 pour cent de l'intensite mesuree) et aux {gamma} de degradation Compton de cette raie (30 pour cent de l'intensite mesuree). Le reste, soit un peu plus de 10 pour cent, doit etre attribue a des causes secondaires telles que les {gamma} de desexcitation nucleaire, le bremsstrahlung interne des particules chargees creees dans les etoiles nucleaires, et aux particules chargees traversant notre detecteur car celui-ci ne comportait pas de dispositif de rejet de ces particules. Les experiences faites en fusees a Colomb-Bechar ont confirme ces resultats et permis de detecter et mesurer un rayonnement {gamma} primaire dont l

  11. Detection of {alpha} particles using semiconductors. Application to the control of plutonium extraction; Detection des particules {alpha} par semiconducteurs application au controle de l'extraction du plutonium

    Energy Technology Data Exchange (ETDEWEB)

    Tanguy, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1968-03-01

    A study is made of a particles produced by thick sources, using either diffused junction or surface barrier semiconductor detectors for controlling continuously the plutonium extraction process. For this, a presenting apparatus is described in which the solutions to be analyzed flow in contact with the detector protected by a thin mica membrane. A method is described which gives a precise recording of the spectra and which thus allows the separation of two or more {alpha} emitters present in the same solution. This method has been applied to the measurement of {sup 239}Pu in the the presence of {sup 241}Am with an accuracy of {+-}5 per cent. In the second part of the report is considered the detection of plutonium in solutions of {beta} - {gamma} emitting fission products. Pile-up is reduced by using a fast amplification chain associated to totally depleted thin detectors. Under these conditions a few mg of {sup 239}Pu can be detected in solutions of fission products having an activity of 100 curies/liter. A method is given for discriminating {alpha} and {beta} particles, it is based on the difference in the collection times for the charges liberated by these particles in the detector. (author) [French] On etudie la detection de particules {alpha} issues de sources epaisses par detecteurs semiconducteurs a jonction diffusee ou a barriere de surface pour le controle continu du procede d'extraction du plutonium. A cet effet on decrit un appareil presentateur dans lequel les solutions a analyser circulent au contact du detecteur protege par une membrane mince de mica. On decrit une methode qui permet par le trace precis des spectres de separer deux ou plusieurs emetteurs {alpha} presents dans une meme solution. Cette methode a ete appliquee a la mesure du {sup 239}Pu en presence de {sup 241}Am avec une precision de {+-} 5 pour cent. Dans la deuxieme partie on traite de la detection du plutonium dans des solutions de produits de fission emetteurs {beta} and {gamma}. On

  12. Etude des désintégrations radiatives des mésons B dans le détecteur ATLAS

    CERN Document Server

    Viret, Sébastien

    2004-01-01

    This thesis is dedicated to the the study radiative B decays with the ATLAS detector at the LHC. Radiative decays belong to the rare decays family. Rare decays transitions involve flavor changing neutral currents (for example b--> s\\gamma), which are forbidden at the lowest order in the Standard Model. Therefore these processes occur only at the next order, thus involving penguin or box diagrams, which are very sensitive to New Physics contributions. The main goal of our study is to show that it would be possible to develop an online selection strategy for radiative B decays with the ATLAS detector. To this end, we have studied the treatment of low energy photons by the ATLAS electromagnetic calorimeter (ECal). Our analysis shows that ATLAS ECal will be efficient with these particles. This property is extensively used in the next section, where a selection strategy for radiative B decays is proposed. Indeed, we look for a low energy region of interest in the ECal as soon as the level 1 of the trigger. Then, p...

  13. Low doses effects and gamma radiations low dose rates; Les effets des faibles doses et des faibles debits de doses de rayons gamma

    Energy Technology Data Exchange (ETDEWEB)

    Averbeck, D [Institut Curie, CNRS UMR 2027, 75 - Paris (France)

    1999-07-01

    This expose wishes for bringing some definitions and base facts relative to the problematics of low doses effects and low dose rates effects. It shows some already used methods and some actual experimental approaches by focusing on the effects of ionizing radiations with a low linear energy transfer. (N.C.)

  14. Detector for the liquid carried over in a gas; Detecteur d'entrainement de liquide dans un gaz

    Energy Technology Data Exchange (ETDEWEB)

    Delisle, J P; Eperonnat, P; Lions, N [Commissariat a l' Energie Atomique, Cadarache (France). Centre d' Etudes Nucleaires

    1965-07-01

    This report describes an optical detector for the detection of a liquid carried over by a gas. The device is sensitive to a cumulated quantity of liquid equal to a few cubic millimetres and is capable of operating an alarm from a distance. The prototype was constructed and tested as detector for the oil leaking in the argon compressed by a diaphragm compressor. A patent for this apparatus under the number: P.V.954.703, has been deposited on 22.11.1963. (authors) [French] Ce rapport decrit un detecteur optique d'entrainement de liquide dans un gaz, sensible a une quantite cumulee de liquide entraine egale a quelques millimetres cubes. L'appareil peut actionner une alarme a distance. Le prototype a ete construit et essaye comme detecteur de fuites d'huile dans l'argon refoule par un compresseur a membranes. Une demande de brevet a ete deposee pour cet appareil sous le numero: P.V.954.703, le 22.11.1963. (auteur)

  15. Identification and localization of neutrino events in the OPERA detector; Identification et localisation des evenements neutrino dans le detecteur OPERA

    Energy Technology Data Exchange (ETDEWEB)

    Heritier, C

    2004-07-15

    The OPERA experiment is designed for the appearance search of {nu}{sub {mu}} {yields} {nu}{sub {tau}} oscillations in the parameters indicated by the atmospheric neutrino anomaly. To prove the appearance of {nu}{sub {tau}} at 732 km from the CERN, an hybrid detector is under construction at the Gran Sasso laboratory. The target, composed by bricks made of lead plates and emulsion sheets, allows the direct observation of the {tau} lepton produced in {nu}{sub {tau}} charged current interactions. The tracking, the localization of neutrino events in the target and the muon identification are allowed by trackers located inside the target (scintillators) and in the spectrometer following the target (RPC). The development of algorithms, based on electronic detectors, is necessary to identify the neutrino interaction and to locate the bricks where the interaction occurred. A classification of neutrino events is performed using the identification of the muon produced in {nu}{sub {mu}} CC and {nu}{sub {tau}} CC with {tau} {yields} {mu} decay. This classification is optimised with tracking informations and also with topological and calorimetric parameters which describe the nature of the interaction (quasi-elastic, deep inelastic); the algorithm of the localization of neutrino event is performed for each category. A tridimensional brick probability map is built and can be exploited to implement sophisticated extraction brick strategies. To conclude, a feasibility study of a test beam experiment OPERETTE is presented. The project was to install a similar OPERA detector in the COMPASS neutrino beam, in the CERN North Area. It was a good opportunity to prepare OPERA for the scanning emulsion films with neutrino events and to test the analysis procedures. (author)

  16. Technique and radiation dose of conventional X-rays and computed tomography of the sacroiliac joint; Technik und Strahlendosis konventioneller Roentgenaufnahmen und Computertomographie des Sakroiliakalgelenks

    Energy Technology Data Exchange (ETDEWEB)

    Jurik, A.G. [Department of Radiology R, Aarhus Kommunehospital (Denmark)

    2004-03-01

    Anterior-posterior (a.p.) or posterior-anterior X-rays of the sacroiliac joint, sometimes supplemented by a transverse view, have been the method of choice for diagnosis of patients suspected of having sacroiliitis. The sensitivity and specificity of conventional X-rays are relatively low, which can delay the diagnosis of sacroiliitis. Computed tomography (CT) is superior to conventional X-rays for diagnosis of sacroiliitis, but does emit a relatively higher dose of radiation. For this reason, particularly for females, CT should be optimized by employing semi-coronal planes, which require a lower radiation dose than axial planes. CT in a semi-coronal plane causes minimal radiation to the ovaries, and the effective radiation dose for women might even be lower than with conventional AP X-rays. Therefore, for suspected sacroiliitis in young women, CT in the semi-coronal plane is the preferred imaging method with respect to diagnostics and radiation protection when magnetic resonance imaging (MRI) is not available. Male gonads can be protected from radiation doses in conventional X-rays, and CT as the primary imaging method can only be justified in these cases because of its better diagnostic capabilities. Due to the lack of inherent risk factors, MRI is superior to CT for diagnostics since it provides images of inflammatory signs in addition to joint destruction. Thus, when available, MRI should be given preference for diagnosis of sacroiliitis. (orig.) [German] Roentgenaufnahmen des Sakroiliakalgelenks im anterior-posterioren bzw. posterior-anterioren Strahlengang, gelegentlich ergaenzt durch die Schraegaufnahme, sind seit vielen Jahren die Methode der Wahl fuer die Diagnostik bei Patienten mit Verdacht auf Sakroiliitis. Die Sensitivitaet und Spezifitaet des konventionellen Roentgens sind relativ niedrig, was die Diagnose der Sakroiliitis verzoegern koennte. Die Computertomographie (CT) ist dem konventionellen Roentgen fuer die Diagnostik der Sakroiliitis ueberlegen

  17. Use of charge storage tube in the building of a buffer memory; Application des tubes a memoire a la realisation d'une memoire tampon

    Energy Technology Data Exchange (ETDEWEB)

    Marcovici, C [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    electrostatiques a grille d'arret. Les informations sont inscrites cote a cote sur un des deux tubes mis en liaison avec ID detecteur, tandis qu'elles sont prelevees sur l'autre par le selecteur pendant un certain temps au bout duquel il y a permutation des roles. L'avantage par rapport aux realisations anterieures est que cette memoire tampon permet un enregistrement continu des informations en sortie du detecteur et un fonctionnement ininterrompu du selecteur. De plus, elle est transistorisee au maximum ce qui l'avantage en fiabilite et facilite de maintenance. L'auteur examine successivement le principe et les caracteristiques du tube a memoire a grille d'arret, il trace un historique des utilisations du tube a memoire en electronique nucleaire, fait une etude statistique de la reduction des pertes au comptage. Il decrit le generateur de tests et les essais qui ont psrmis de selectionner le tube a memoire le plus apte a la realisation de la memoire et enfin presente le dispositif et les formes d'ondes en differents points de ta memoire. (auteur)

  18. Radiation Treatment of Meat Products and Animal By-Products; Traitement par Rayonnements des Viandes et Derives et des Sous-Produits Animaux; Radiatsionnaya obrabotka myasnykh produktov i subproduktov zhivotnogo proiskhozhdeniya; Irradiacion de la Carne y sus Derivados

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, P. -I.E. [Danish Meat Research Institute, Roskilde (Denmark)

    1966-11-15

    Application of radiation in food technology can only be considered as an alternative to existing preservation methods when a higher quality product and/or a cheaper product will result, or in cases where no alternative methods exist. With this view in mind, work performed at the Danish Meat Research Institute on sliced bacon, canned hams, luncheon meat, and animal feeding stuffs, i.e. meat and bone meal and blood meal, is reviewed and discussed. The conclusion drawn from the experimental results is that the formation of off-flavours in irradiated meat products is a very serious problem and the most important obstacle to a successful application of irradiation in meat processing. It is, therefore, essential that future research should concentrate on finding means to reduce the irradiation flavour. A number of approaches to solve this problem are mentioned and the Danish work in this field which has been centred mainly on the use of very high dose-rates and of non-equal dose distribution in cans is reviewed, and the concepts briefly described. (author) [French] L'application des rayonnements dans l'industrie alimentaire ne saurait etre consideree en remplacement des methodes de conservation actuelles que s'il en resulte un produit de qualite superieure ou un produit meilleur marche, ou encore lorsqu'on ne peut utiliser aucune methode de rechange. Dans cet esprit, l'auteur examine et commente les travaux accomplis par l'Institut danois de recherches sur la viande concernant le lard en tranches, le jambon en conserve, les pates de viande en conserve (luncheon meat) et les aliments pour animaux, c'est-a-dire les farines de viande et d'os et la farine de sang. Il conclut des resultats experimentaux que la formation de gouts indesirables dans les viandes irradiees pose un probleme tres serieux et constitue l'obstacle le plus important au succes de l'application des rayonnements a la preparation des viandes. Il importe donc que les futures recherches portent avant tout sur

  19. Neutron distribution in the central cell and a peripheral cell of the Fontenay-aux-Roses pile; Repartition des neutrons dans la cellule centrale et une cellule peripherique de la pile de Fontenay-aux-Roses

    Energy Technology Data Exchange (ETDEWEB)

    Roullier, F [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1958-07-01

    The distribution of the neutron density has been determined in the central cell and a peripheral cell of the pile at Fontenay-aux-Roses. This measurement was carried out by the autoradiographic method with manganese detectors. The neutron density distribution in the uranium rod has already been studied. The measurement was completed by the study of the neutron density in the complete cell by means of detectors placed in the uranium and in the heavy water. (author) [French] La repartition de la densite des neutrons a ete determinee dans la cellule centrale et une cellule peripherique de la pile de Fontenay-aux-Roses. Cette mesure a ete effectuee par la methode d'autoradiographie avec des detecteurs de manganese. La repartition de la densite des neutrons dans la barre d'uranium a deja ete etudiee. La mesure a ete completee par l'etude de la densite des neutrons dans la cellule complete a l'aide de detecteurs places dans l'uranium et dans l'eau lourde. (auteur)

  20. The Effect of Gamma Radiation on the Fertility and Longevity Of Dolichoderus Quadripunctatus (Hymenoptera: Formicoidea Dolichoderidae); Effets des Radiations Gamma sur la Fertilite et la Longevite des Colonies de Dolichoderus Quadripunctatus (Hymenoptere: Formicoidea Dolichoderidae)

    Energy Technology Data Exchange (ETDEWEB)

    Torossian, C. [Faculte des Sciences, Universite de Toulouse (France); Causse, R. [INRA, Station de Zoologie, Centre de Recherches Agronomiques du Sud-Est, Montfavet (France)

    1968-06-15

    la fertilite, d'irradiations gamma a des valeurs comprises entre 12 500 et 150 000 rad; les resultats obtenus sont donnes dans le memoire. Dans le cas des colonies exclusivement composees d'ouvrieres la courbe de mortalite est lineaire pour des valeurs comprises entre 150 000 et 50 000 rad. La DL 50 est atteinte en 4 jours pour la dose de 150 000 rad, et 16 jours pour la dose de 50 000 rad. Aux valeurs les plus faibles(12 500 rad) la DL 50 s'obtient apres 18 jours. Pour les colonies temoins la DL50 s'obtient en 30 jours environ. La fecondite, qui est habituellement reguliere et constante dans les colonies d'ouvrieres, est exprimee par le rapport QR = quotient reproducteur (nombre d'oeufs/nombre d'ouvrieres au debut de l'experience). Le QR des colonies temoins (n' ayant subi aucune irradiation) a pour valeur 1,60 environ. Le QR des colonies traitees varie entre 0 et 0,06. Ces valeurs extremement faibles montrent que les colonies traitees sont devenues pratiquement steriles. Cette sterilite est definitive, car jusqu'a l'extinction de la colonie, aucune ponte n' a pu etre observee dans les colonies irradiees. Dans les colonies avec reine, seules les reines subissent une irradiation gamma, aux valeurs de 50 000, 100 000 et 150 000 rad. Les resultats obtenus concernant la longevite montrent dans tous les cas une resistance considerablement plus elevee des femelles que pour les ouvrieres placees dans les memes conditions. Pour ce qui est de la fecondite, on observe chez les reines irradiees un ralentissement considerable et quasi immediat de leur ponte. Ce ralentissement est suivi dans les colonies par une reprise de la ponte des ouvrieres: la reine ne peut plus exercer l'inhibition de leur ponte. Par la suite, la fecondite des reines irradiees diminue et devient nulle 3 partir du 18{sup e} jour. Il n'y a plus de reprise de la ponte des reines par la suite. (author)

  1. Detection of {alpha} particles using semiconductors. Application to the control of plutonium extraction; Detection des particules {alpha} par semiconducteurs application au controle de l'extraction du plutonium

    Energy Technology Data Exchange (ETDEWEB)

    Tanguy, J. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1968-03-01

    A study is made of a particles produced by thick sources, using either diffused junction or surface barrier semiconductor detectors for controlling continuously the plutonium extraction process. For this, a presenting apparatus is described in which the solutions to be analyzed flow in contact with the detector protected by a thin mica membrane. A method is described which gives a precise recording of the spectra and which thus allows the separation of two or more {alpha} emitters present in the same solution. This method has been applied to the measurement of {sup 239}Pu in the the presence of {sup 241}Am with an accuracy of {+-}5 per cent. In the second part of the report is considered the detection of plutonium in solutions of {beta} - {gamma} emitting fission products. Pile-up is reduced by using a fast amplification chain associated to totally depleted thin detectors. Under these conditions a few mg of {sup 239}Pu can be detected in solutions of fission products having an activity of 100 curies/liter. A method is given for discriminating {alpha} and {beta} particles, it is based on the difference in the collection times for the charges liberated by these particles in the detector. (author) [French] On etudie la detection de particules {alpha} issues de sources epaisses par detecteurs semiconducteurs a jonction diffusee ou a barriere de surface pour le controle continu du procede d'extraction du plutonium. A cet effet on decrit un appareil presentateur dans lequel les solutions a analyser circulent au contact du detecteur protege par une membrane mince de mica. On decrit une methode qui permet par le trace precis des spectres de separer deux ou plusieurs emetteurs {alpha} presents dans une meme solution. Cette methode a ete appliquee a la mesure du {sup 239}Pu en presence de {sup 241}Am avec une precision de {+-} 5 pour cent. Dans la deuxieme partie on traite de la detection du plutonium dans des solutions de produits de fission emetteurs {beta} and {gamma

  2. Biological Effects of Ionising Radiation and Countermeasures (Les effets biologiques des rayonnements ionisants et leurs contre-mesures)

    Science.gov (United States)

    2018-01-01

    radiation physicists. As an example, a special issue of Health Physics [3] presents a body of experimental work characterizing the outdoor...Terrorist Attack involving Ionising Radiation. Campus Vesta, Belgium September 25-29, 2016. [3] Health Physics (Special Issue) 2016:110;399- 547...of Radiobiology & Radiation Protection 128 Szaserów Street 04-141 Warsaw POLAND Email: mjaniak@wihe.waw.pl Mr. Tjerk KUIPERS Health Physics

  3. Biological effects of the ionizing radiation. Press breakfast; Effets biologiques des rayonnements ionisants. Petit dejeuner de presse

    Energy Technology Data Exchange (ETDEWEB)

    Flury-Herard, A [CEA, Direction des Sciences du Vivant, DSV, 75 - Paris (France); Boiteux, S; Dutrillaux, B [CEA/Fontenay-aux-Roses, Direction des Sciences du Vivant, DSV, 92 (France); Toledano, M [CEA Saclay, Direction des Sciences du Vivant, DSV, 91 - Gif-sur-Yvette (France)

    2000-06-01

    This document brings together the subjects discussed during the Press breakfast of 29 june 2000 on the biological effects of the ionizing radiations, with scientists of the CEA and the CNRS. It presents the research programs and provides inquiries on the NDA operating to introduce the NDA damages by ionizing radiations, the possible repairs and the repair efficiency facing the carcinogenesis. Those researches allow the scientists to define laws on radiation protection. (A.L.B.)

  4. The power of MAIC and the challenges for radiation protection; Die Macht des MAIK und die Herausforderungen fuer den Strahlenschutz

    Energy Technology Data Exchange (ETDEWEB)

    Gellermann, R.

    2016-07-01

    The ''radioactive'' radiation has proved to be a medial usable theme of the anti-nuclear movement in recent decades. This has caused significant political changes in Germany. The article tries to outline a phenomenon that can be described as Medial-Antinuclear Interests Complex (MAIC). The views on radiation and radiation risks propagated by MAIC to the public have demonized the disposal of radioactive waste. This results in situations, which tacitly accept unnecessary risks for the population. A new approach for raising the public awareness in particular regarding long-term safety and radiation protection is possible and necessary.

  5. A Theory of Radioisotope Scanning Systems; Une Theorie des Systemes de Scintigraphoe au Moyen des Radioisotopes; Teoriya sistem radioizotopnogo skennirovaniya; Teoria de los Sistemas de Exploracion Radioisotopica

    Energy Technology Data Exchange (ETDEWEB)

    Beck, R. N. [Argonne Cancer Research Hospital, University of Chicago, Chicago, IL (United States)

    1964-10-15

    realized that the advantages of resolving power as a criterion of quality are largely illusory''. Borrowing from that field, the concept of ''sine wave response'' is introduced to define resolution of collimated scintillation detectors for d istributed sources. (author) [French] Le principal objet d'une theorie generale des systemes de scintigraphie est de predire et d'evaluer les performances de systemes hypothetiques concus a des fins bien determinees, par exemple pour la detectiondes tumeurs cerebrales. Une telle theorie devrait donner des responses quantitatives a des questions telles que la suivante: 'Pour la detection de tumeurs cerebrales d'une certaine dimension, profondeur, etc., faut-il utiliser un scintigraphe concu pour u'I ou pour {sup 203}Hg?' L'auteur cherche a coordonner les divers elements d'une telle theorie et a etablir des equations exprimant les rapports entre les parametres biologiques et physiques a considerer: dimension et profondeur de la tumeur, taux de fixation, sensibilite du collimateur, pouvoir de resolution, distance focale, surface du scintigramme, temps d'exploration, fiabilite, etc. L'element essentiel de cette theorie est un critere ou indice de qualite pouvant etre calcule pour n'importe quel systeme et utilise pour la comparaison de divers systemes. L'auteur discute des indices de qualite fondes sur la perception visuelle et la theorie de l'information et adopte un indice fonde sur la statistique. Cet indice est une fonction de la sensibilite et de la resolution du detecteur; l'une et l'autre sont etudiees de maniere detaillee. L'auteur analyse la reponse du collimateur pour des sources de radioactivite ponctuelles et pour des sources distribuees dans un plan ou dans l'espace. La reponse totale [E{sub t} = E(l+P+S)] d'un detecteur.collimate, dirige sur une source de grande surface, est la somme de trois composantes dues aux rayons gamma qui penetrent dans le collimateur: a)'geometriquement'ou de facon normale (E); b) a travers les

  6. Occupational radiation exposure in Germany in 2012. Report of the radiation protection register; Die berufliche Strahlenexposition in Deutschland 2012. Bericht des Strahlenschutzregisters

    Energy Technology Data Exchange (ETDEWEB)

    Frasch, Gerhard; Kammerer, Lothar; Karofsky, Ralf; Mordek, Else; Schlosser, Andrea; Spiesl, Josef

    2014-04-15

    In Germany, persons who are occupationally exposed to ionising radiation are monitored by several official dosimetry services that transmit the dose records about individual radiation monitoring to the Radiation Protection Register of the Federal Office for Radiation Protection (BfS). The purpose of the Radiation Protection Register is to supervise the keeping of the dose limits and to monitor the compliance with the radiation protection principle ''Optimisation'' by performing detailed annual statistical analyses of the monitored persons and their radiation exposure. The annual report of the Radiation Protection Register provides information about status and development of occupational radiation exposure in Germany. In 2012, about 350,000 workers were monitored with dosemeters for occupational radiation exposure. The number increased continuously by totally 10 % into the past five years. 19 % of the monitored persons received measurable personal doses. The average annual dose of these exposed workers was 0.52 mSv corresponding to 2.6 % of the annual dose limit of 20 mSv for radiation workers. In total, 2 persons exceeded the annual dose limit of 20 mSv, i.e. less than one case per 100,000 monitored persons. The collective dose of the monitored persons decreased to 27.9 Person-Sv, the lowest value since the last fifty years of occupational dose monitoring. 45 airlines calculated the route doses of 40,000 aircraft crew members by using certified computer programmes for dose calculation and sent the accumulated monthly doses via the Federal Office for Civil Aviation (''Luftfahrt-Bundesamt, LBA'') to the BfS. The collective dose of the aircraft crew personnel is 78.5 person- Sv, and thus significantly higher than the total collective dose of the workers monitored with personal dosemeters. The annual average dose of aircraft crew personnel was 1.96 mSv and decreased compared to 2011 (2.12 mSv) due to solar cycle. In 2012, about

  7. Late effects of radiation on mature and growing bone; Effets tardifs des radiations sur l`os mature et en croissance

    Energy Technology Data Exchange (ETDEWEB)

    Ramuz, O.; Mornex, F. [Centre Hospitalier Universitaire Lyon-Sud, 69 - Pierre-Benite (France); Bourhis, J. [Institut Gustave Roussy, 94 - Villejuif (France)

    1997-12-01

    The physiopathology of radiation-induced bone damage is no completely elucidated. Ionizing radiation may induce an inhibition or an impairment of growing bone. This fact is of particular importance in children, and represents one of the most important dose-limiting factors in the radiotherapeutic management of children with malignant diseases. Scoliosis, epiphyseal slippage, avascular necrosis, abnormalities of craniofacial growth may be observed after radiation. Child`s age at the time of treatment, location of irradiated bone and irradiation characteristics may influence the radiation related observed effects. In adults, pathological analysis of mature bone after ionizing radiation exposure are rare, suggesting that it is difficult to draw a clear feature of the action of radiation on the bone. Osteoporosis, medullary fibrosis and cytotoxicity on bone cells lead to fracture or necrosis. Various factors can influence bone tolerance to radiation such as bone involvement by tumor cells or infection, which is frequent is mandibulary osteoradionecrosis. Technical improvements in radiation techniques have also decreased radio-induced bone complications : the volume, fractionation and total dose are essential to consider. The absence of a consistent radiation-induced late effects evaluation scale has hampered efforts to analyze the influence of various therapeutic maneuvers and the comparison of results from different reported series. The currently proposed evaluation scale may help harmonizing the classification of radiation-induced bone late effects. (author)

  8. Radiation Polymerization of Acetylene Hydrocarbons. Special Features; Particularites de la polymerisation radiochimique des hydrocarbures acetyleniques; Radiatsionnaya polimerizatsiya atsetilenovykh proizvodnykh; Particularidades de la radiopolimerizacion de los hidrocarburos acetilenicos

    Energy Technology Data Exchange (ETDEWEB)

    Barkalov, I. M.; Gol' danskij, V. I.; Go, Min' -Gao

    1963-11-15

    benzene radical. The pronounced deviations from the additivity rule in the case of radiation polymerization in different solvents indicate a large energy transfer to acetylene hydrocarbons and their polymers. (author) [French] La synthese des polymeres a systeme reticule et l'etude de leurs proprietes constituent une branche nouvelle et tres riche en promesses de la chimie des composes a poids moleculaire eleve. Les polymeres de ce type sont caracterises par un haut degre de deplacement des electrons p dans la macromolecule. La reduction de l'energie d'excitation jusqu'a formation de la triple liaison et la diminution du potentiel d'ionisation en presence de longues chafhes de reticulation sont a l'origine des proprietes semi-conductrices et des particularites magnetiques specifiques de ces composes. En outre, ces systemes reticules se sont reveles tres efficaces comme stabilisateurs contre la destruction des polymeres par thermo-oxydation et photo-oxydation. Une methode pratique pour obtenir des polymeres de ce genre est fournie par la polymerisation radiochimique des derives de l'acetylene. Elle seule permet d'obtenir, a basse temperature, des polymeres libres de toute impurete due aux initiateurs. La cinetique de la polymerisation radiochimique du phenylacetylene et d'autres derives de l'acetylene presente une serie de traits qui sont caracteristiques de la polymerisation ionique mais tout a fait inhabituels pour la polymerisation par radicaux (vitesse de polymerisation preportionnelle a la vitesse d'amorcage; energie d'activation tres faible; absence d'inhibition par l'oxygene). Neanmoins, cette polymerisation semble etre due a l'action des radicaux. Les auteurs sont parvenus a cene conclusion, en etudiant l'amorcage de la polymerisation des hydrocarbures acetyleniques par des initiateurs ayant le caractere typique d'un radical, tel que le peroxyde de benzoide et le dinitryle de l'acide azo-i-butyrique. A ce propos, ils ont examine les particularites de la cinetique

  9. Contribution to the study of the action of electromagnetic fields on the angular correlations of nuclear radiation (1960); Contribution a l'etude de l'action des champs electromagnetiques sur les correlations angulaires des rayonnements nucleaires (1960)

    Energy Technology Data Exchange (ETDEWEB)

    Lehmann, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1959-01-15

    This work deals with the study of interaction of E.M. fields with nuclear moments of nuclei emitting gamma rays. We describe first experiments on delayed angular correlation showing the role played by statistic quadrupole interaction. We have measured the magnetic moment of the second excited state of {sup 19}F using an external magnetic field. In the case of {sup 19}O, experiments of angular distributions and angular correlations of gamma -rays taking into account the possibility of perturbations, allow us to determine the spin and parities of the three first levels. (author) [French] Le present travail concerne l'etude de l'interaction des champs electromagnetiques et des moments nucleaires de noyaux emettant des rayonnements gamma. Nous decrivons des experiences de correlation angulaire differee dont l'interpretation met en coincidence le role joue par les interactions quadrupolaires statiques. Nous avons mesure le moment magnetique de {sup 19}F dans un etat excite en utilisant un champ magnetique exterieur a la source radioactive. Enfin, dans le cas de {sup 19}O, nous montrons l'utilite d'un examen des possibilites de perturbations dans l'interpretation des resultats fournis par des correlations ou des distributions angulaires. (auteur)

  10. Contribution to the study of the action of electromagnetic fields on the angular correlations of nuclear radiation (1960); Contribution a l'etude de l'action des champs electromagnetiques sur les correlations angulaires des rayonnements nucleaires (1960)

    Energy Technology Data Exchange (ETDEWEB)

    Lehmann, P. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1959-01-15

    This work deals with the study of interaction of E.M. fields with nuclear moments of nuclei emitting gamma rays. We describe first experiments on delayed angular correlation showing the role played by statistic quadrupole interaction. We have measured the magnetic moment of the second excited state of {sup 19}F using an external magnetic field. In the case of {sup 19}O, experiments of angular distributions and angular correlations of gamma -rays taking into account the possibility of perturbations, allow us to determine the spin and parities of the three first levels. (author) [French] Le present travail concerne l'etude de l'interaction des champs electromagnetiques et des moments nucleaires de noyaux emettant des rayonnements gamma. Nous decrivons des experiences de correlation angulaire differee dont l'interpretation met en coincidence le role joue par les interactions quadrupolaires statiques. Nous avons mesure le moment magnetique de {sup 19}F dans un etat excite en utilisant un champ magnetique exterieur a la source radioactive. Enfin, dans le cas de {sup 19}O, nous montrons l'utilite d'un examen des possibilites de perturbations dans l'interpretation des resultats fournis par des correlations ou des distributions angulaires. (auteur)

  11. Occupational radiation exposure in Germany in 2011. Report of the radiation protection register; Die berufliche Strahlenexposition in Deutschland 2011. Bericht des Strahlenschutzregisters

    Energy Technology Data Exchange (ETDEWEB)

    Frasch, Gerhard; Kammerer, Lothar; Karofsky, Ralf; Mordek, Else; Schlosser, Andrea; Spiesl, Josef

    2013-04-15

    In Germany, persons who are occupationally exposed to ionising radiation are monitored by several official dosimetry services that transmit the dose records about individual radiation monitoring to the Radiation Protection Register of the Federal Office for Radiation Protection (BfS). The purpose of the Radiation Protection Register is to supervise the keeping of the dose limits and to monitor the compliance with the radiation protection principle ''Optimisation'' by performing detailed annual statistical analyses of the monitored persons and their radiation exposure. The annual report of the Radiation Protection Register provides information about status and development of occupational radiation exposure in Germany. In 2011, about 350,000 workers were monitored with dosemeters for occupational radiation exposure. The number increased during the past five years continuously by 10 %. Only 19 % of the monitored persons received measurable personal doses. The average annual dose of these exposed workers was 0.58 mSv corresponding to 3 % of the annual dose limit of 20 mSv for radiation workers. In total, 7 persons exceeded the annual dose limit of 20 mSv, i.e. two cases per 100,000 monitored persons. The collective dose of the monitored persons decreased to 38.5 Person-Sv, the lowest value since the last fifty years of occupational dose monitoring. In 2010, 45 airlines calculated the route doses of 39,000 members of the aircraft crew personnel by using certified computer programmes for dose calculation and sent the accumulated monthly doses via the Federal Office for Civil Aviation (''Luftfahrt-Bundesamt, LBA'') to the BfS. The collective dose of the aircraft crew personnel is 83 person-Sv, and thus significantly higher than the total collective dose of the workers monitored with personal dosemeters (38.5 person-Sv). The annual average dose of aircraft crew personnel was 2.12 mSv and decreased compared to 2010 (2,30 mSv). In 2011

  12. Ionizing radiation sources: very diversified means, multiple applications and a changing regulatory environment. Conference proceedings; Les sources de rayonnements ionisants: des moyens tres diversifies, des applications multiples et une reglementation en evolution. Recueil des presentations

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-11-15

    This document brings together the available presentations given at the conference organised by the French society of radiation protection about ionizing radiation source means, applications and regulatory environment. Twenty eight presentations (slides) are compiled in this document and deal with: 1 - Overview of sources - some quantitative data from the national inventory of ionizing radiation sources (Yann Billarand, IRSN); 2 - Overview of sources (Jerome Fradin, ASN); 3 - Regulatory framework (Sylvie Rodde, ASN); 4 - Alternatives to Iridium radiography - the case of pressure devices at the manufacturing stage (Henri Walaszek, Cetim; Bruno Kowalski, Welding Institute); 5 - Dosimetric stakes of medical scanner examinations (Jean-Louis Greffe, Charleroi hospital of Medical University); 6 - The removal of ionic smoke detectors (Bruno Charpentier, ASN); 7 - Joint-activity and reciprocal liabilities - Organisation of labour risk prevention in case of companies joint-activity (Paulo Pinto, DGT); 8 - Consideration of gamma-graphic testing in the organization of a unit outage activities (Jean-Gabriel Leonard, EDF); 9 - Radiological risk control at a closed and independent work field (Stephane Sartelet, Areva); 10 - Incidents and accidents status and typology (Pascale Scanff, IRSN); 11 - Regional overview of radiation protection significant events (Philippe Menechal, ASN); 12 - Incident leading to a tritium contamination in and urban area - consequences and experience feedback (Laurence Fusil, CEA); 13 - Experience feedback - loss of sealing of a calibration source (Philippe Mougnard, Areva); 14 - Blocking incident of a {sup 60}Co source (Bruno Delille, Salvarem); 15 - Triggering of gantry's alarm: status of findings (Philippe Prat, Syctom); 16 - Non-medical electric devices: regulatory changes (Sophie Dagois, IRSN; Jerome Fradin, ASN); 17 - Evaluation of the dose equivalent rate in pulsed fields: method proposed by the IRSN and implementation test (Laurent Donadille

  13. Survey of radiation protection programmes for transport; Etude des programmes de radioprotection pour les transports de matieres radioactives

    Energy Technology Data Exchange (ETDEWEB)

    Lizot, M.T.; Perrin, M.L.; Sert, G. [CEA Fontenay-aux-Roses, Inst. de Protection et de Surete Nucleaire, Dept. de Protection et de Surete Nucleaire, 92 (France); Lange, F.; Schwarz, G.; Feet, H.J.; Christ, R. [Gesellschaft fur Anlagen-und Reaktorsicherheit, GRS, mbH, Cologne (Germany); Shaw, K.B.; Hughes, J.S.; Gelder, R. [National Radiological Protection Board (NRPB), Oxon, OX (United Kingdom)

    2001-07-01

    The survey of radiation protection programmes for transport has been jointly performed by three scientific organisations I.P.S.N. (France), G.R.S. ( Germany), and N.R.P.B. (United kingdom) on behalf of the European Commission and the pertaining documentation summarises the findings and conclusions of the work that was undertaken with the principal objectives to provide guidance on the establishment, implementation and application of radiation protection programmes for the transport of radioactive materials by operators and the assessment and evaluation of such programmes by the competent authority and to review currently existing radiation protection programmes for the transport of radioactive materials. (N.C.)

  14. LUBW. For 40 years now rendering good services for radiation protection; LUBW. Seit 40 Jahre im Dienste des Strahlenschutzes

    Energy Technology Data Exchange (ETDEWEB)

    Kringler, Jochen [Landesanstalt fuer Umweltschutz Baden-Wuerttemberg (LUBW), Karlsruhe (Germany). Referat Radioaktivitaet, Strahlenschutz

    2016-08-01

    Formation, development and tasks of the ''State Institute for Environment, Measurements and Nature Conservation Baden-Wuerttemberg'' are described. They include, for instance, nature protection and climatic consequences as well as production safety, environmental techniques, water cleanliness and soil protection. However, above all the evaluation and recording of radioactivity and the measurement of ionizing radiation were from the beginning some of the main assignments. Today very important are research of the presence of radioactivity in the environment, measurement of radiation levels around nuclear facilities and support of the nuclear inspectorate in questions of radiation protection.

  15. Causes of Accidents Near Accelerators and Radiation Protection Arrangements; Causes d'accidents aupres des accelerateurs et dispositions de radioprotection

    Energy Technology Data Exchange (ETDEWEB)

    Joffre, H; Vialettes, H [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1968-07-01

    The authors present, first, some typical accidents mentioned in bibliography or happened in CEA Research Centers. The accidents are analysed to precise the main cause and get some experience. Then the authors study the interest of a centralized control for security, detection and signalling devices used near every important accelerator. (author) [French] Les auteurs presentent, tout d'abord, quelques accidents typiques rapportes dans la bibliographie ou survenus dans les Centres de Recherches du CEA. Ces accidents sont analyses pour en preciser la cause principale et en degager les enseignements. Enfin les auteurs etudient l'interet d'un controle centralise des dispositifs de securite, de detection et de signalisation mis en oeuvre aupres de tout accelerateur important. (auteur)

  16. The search for charginos and neutralinos with the ATLAS detector at LHC; La recherche des charginos et des neutralinos avec le detecteur Atlas au LHC

    Energy Technology Data Exchange (ETDEWEB)

    Muanza, G.S.

    1996-05-01

    This thesis concerns the prospective study to evidence the supersymmetry with the ATLAS detector at the CERN Large Hadron Collider (LHC) by searching for the disintegration of chargino-neutralino pairs into three leptons. The analysis of this channel is performed through a rapid simulation of the detector used for the signal processing and to process the background (from the standard model and from the MSSM) which may hinder the detection. The results are given for different configurations of LHC: at low energy ({radical}s = 9.3 TeV), at high energy ({radical}s = 14 TeV), at low luminosity (L = 10 sup 3 sup 3 cm sup -2 sup -1), at high luminosity (L = 10 sup 3 sup 4 cm sup -2 sup -1). Finally, we propose an original method allowing the estimation of the gluino mass (an essential parameter of the MSSM) as well as that of all the charginos and neutralinos. This method is of course approximated but it relies on a unique experimental measurement and permits the rebuilding of the whole mass spectrum of the MSSM jauginos to be performed with a worthy precision. The experimental part of this thesis deals with the tests performed on the new photomultipliers (PMTs) HAMAMATSU R5900 which are foreseen for the outfit of the ATLAS tile calorimeter TICAL. The results of these tests show that the PMTs are in conformity with the specifications of the reading of TICAL. (N.T.).

  17. 20 years after Chernobyl. A radiation protection perspective; 20 Jahre nach Tschernobyl. Eine Bilanz aus Sicht des Strahlenschutzes

    Energy Technology Data Exchange (ETDEWEB)

    Baldauf, D.; Gumprecht, D.; Heller, H. (comps.)

    2006-07-01

    Together with the Bhopal and Seveso accident, the Chernobyl accident was the biggest distaster in the application of technologies. There was much suffering involved which should not be forgotten. On the other hand, a scientific organization like the Radiation Protection Commission (SSK) must take care to distinguish between injuries caused by radiation and others not caused by radiation. While this may appear cold-hearted, there is a need for a detailed scientific analysis in order to gain information for better radiation protection in the future. In this volume, SSK therefore attempts to answer questions concerning the effects of the reactor accident in the Chernobyl region and also in Germany. On the basis of the contribution, SSK drew up a comprehensive statement which was passed in the SSK meeting of 1 March 2006. (orig.)

  18. Country-overlapping radiation protection education and training by the CHERNE network; Laenderuebergreifende Strahlenschutzausbildung im Rahmen des CHERNE-Netzwerks

    Energy Technology Data Exchange (ETDEWEB)

    Hoyler, Frieder [Fachhochschule Aachen, Juelich (Germany). Strahlenschutzkursstaette

    2013-09-01

    The CHERNE network is promoting the cooperation between colleges and research facilities at the training of students. The article describes particular study courses in the field of radiation protection. (orig.)

  19. Actual questions of radiographic testing and radiation protection. Contributions; Aktuelle Fragen der Durchstrahlungspruefung und des Strahlenschutzes. Beitraege

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2017-08-01

    The proceedings of the 17th DGZfP seminar include nine contributions on the use of radiography for periodic non destructive testing purposes and issues of radiation protection for the testing personnel and the security of radioactive materials.

  20. Contribution to the study and use of ionisation chambers for nuclear reactor control (1965); Contribution a l'etude et a l'utilisation des chambres d'ionisation pour le controle des reacteurs nucleaires (1965)

    Energy Technology Data Exchange (ETDEWEB)

    Duchene, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-02-15

    high-power reactors. (author) [French] Les chambres d'ionisation sont actuellement les detecteurs les mieux adaptes au controle des reacteurs nucleaires par des mesures neutroniques. Nous avons cru bon de rappeler quelques generalites concernant la dynamique des reacteurs, les differents procedes de detection des neutrons, le fonctionnement des chambres d'ionisation et les methodes de mesure utilisees. Notre contribution aux techniques de controle des reacteurs consiste d'une part en une tentative de synthese des facteurs intervenant dans le fonctionnement des chambres d'ionisation, l'etude de ces facteurs, et d'autre part l'elaboration de chambres d'ionisation a fission et a bore permettant de suivre la marche d'un reacteur du demarrage jusqu'a la puissance maximale. Dans le domaine des chambres a fission, nous avons en particulier ameliore les techniques de depot d'oxyde d'uranium sur l'aluminium et realise la mise au point de depots par electrolyse sur d'autres metaux: acier inoxydable, cuivre, molybdene, nickel, tantale, titane, kovar, tungstene et beryllium. Nous avons elabore plusieurs types de chambres a fission servant au demarrage des reacteurs: un type de performances moyennes actuellement utilise dans les piles francaises un type a haute sensibilite un type a haute temperature qui a fonctionne jusqu'a 600 deg. C. En ce qui concerne les chambres a bore, nous avons etudie les perturbations apportees dans les mesures par l'exposition des chambres a d'importants flux de neutrons et a un rayonnement {gamma} intense. Cette exposition produit une modification des proprietes des materiaux constitutifs et la production dans les chambres d'un bruit de fond qui peut gener considerablement les mesures neutroniques. Nous avons montre que la technique de compensation permettait de limiter l'importance de ce bruit de fond et d'augmenter ainsi la plage de fonctionnement des chambres d'ionisation classiques destinees aux mesures de puissance. Enfin, nous avons realise deux

  1. The radiation age of meteorites; L'age des meteorites; Opredelenie vozrasta meteoritov s pomoshch'yu radiatsii; Edad de los meteoritos

    Energy Technology Data Exchange (ETDEWEB)

    Goebel, K; Schmidlin, P [European Organisation for Nuclear Research, Geneva (Switzerland)

    1962-01-15

    Radioisotopes produced by cosmic radiation in meteorites while travelling through space can be used to trace the history of these meteorites. The radioisotopes and the accumulated daughter-elements in the meteorite must be determined in order to evaluate how long the meteorite was exposed to cosmic radiation. (It must be assumed for this calculation that the flux of the cosmic radiation is constant with time.) Most often gaseous isotopes have been used for these measurements as they can be easily separated from the meteoric substance. In the reported work tritium and argon have been mainly used. From the ratio H{sup 3}/He{sup 3}, radiation ages from a few millions to several hundred millions of years have been found. The recent measurements made at the European Organisation for Nuclear Research (CERN) agree in principle with results from other sources. The probable errors from diffusion-losses of gas and the influence of shielding in the pre-atmospheric meteorite are discussed in the paper. By taking into consideration the measured cross-section for tritium production in the elements which form the meteorite, the values of the cosmic-ray flux in outer space can be determined. (author) [French] Les radioisotopes produits par les rayonnements cosmiques dans les meteorites circulant dans l'espace peuvent servir a reconstituer l'histoire de ces corps. Il faut mesurer les radioisotopes et les produits de filiation accumules dans la meteorite pour evaluer le temps pendant lequel la meteorite a ete exposee aux rayonnements cosmiques. (On considere alors que le flux des rayonnements cosmiques ne varie pas dans le temps.) Pour ces mesures, on se fonde le plus souvent sur les isotopes gazeux parce qu'il est facile de les separer de la substance meteorique. Dans les recherches qui font l'objet du present memoire, il s'agissait surtout du tritium et de l'argon. En partant du rapport {sup 3}H/{sup 3}He, on a pu evaluer des ages allant de quelques millions a plusieurs centaines

  2. Conformal radiation therapy of localized prostate cancer: acute tolerance and early evaluation of effectiveness; Konformierende Strahlentherapie des lokalisierten Prostatakarzinoms: Akute Toleranz und fruehe Wirksamkeit

    Energy Technology Data Exchange (ETDEWEB)

    Zierhut, D. [Klinische Radiologie, Radiologische Universitaetsklinik Heidelberg (Germany); Flentje, M. [Klinische Radiologie, Radiologische Universitaetsklinik Heidelberg (Germany); Sroka-Perez, G. [Klinische Radiologie, Radiologische Universitaetsklinik Heidelberg (Germany); Rudat, V. [Klinische Radiologie, Radiologische Universitaetsklinik Heidelberg (Germany); Engenhart-Cabillic, R. [Klinische Radiologie, Radiologische Universitaetsklinik Heidelberg (Germany); Wannenmacher, M. [Klinische Radiologie, Radiologische Universitaetsklinik Heidelberg (Germany)

    1997-02-01

    Aim: In a prospective trial early effectiveness and acute toxicity of conformal 3D-planned radiotherapy for localized prostate cancer was quantified using dose-volume-histogramms and evaluated with respect of treatment technique. Results: Eleven patients (of 32) had none, 15 mild (RTOG grade 1) and 6 moderate symptoms (RTOG grade 2, mainly diarrhoea, dysuria and polyuria). Acute complications leading to treatment interruption did not occur. In 16 patients symptoms disappeared within 6 weeks after radiotherapy. Only 2 men had symptoms which lasted longer than 3 months and were endoscopically examined. Up to now no late complications were detected. Incidence and severity of toxicity was significantly (p<0,05) related to the size of treatment volume. Akute toxicity was found to depend statistically significant (p<0,05) on the proportional volume of bladder and rectum, irradiated with more than 35 Gy. In 81% of the patients with pretherapeutic elevated PSA levels normalisation of PSA was observed. Overall mean PSA levels of 15.7{+-}22.6 {mu}g/l at the beginning of radiotherapy fell to 2.1{+-}3.7 {mu}g/l 6 weeks after irradiation. Only 1 Patient relapsed locally 22 months after radiation therapy. Conclusion: We conclude that due to modern 3D-planned conformal techniques with optimization of treatment dose and improved protection of critical organs such as urinary bladder and rectum, radiotherapy allows an effective and well tolerated therapy of localized prostatic carcinoma. (orig./VHE) [Deutsch] Ziel: Quantifizierung der fruehen Wirksamkeit und akuten Toxizitaet der 3D-geplanten und konformierenden Strahlentherapie des lokalisierten Prostatakarzinoms mittels Dosis-Volumen-Histogramm sowie Untersuchung der Abhaengigkeit von der Bestrahlungstechnik in einer prospektiven Studie. Ergebnisse: Elf Patienten hatten keine, 15 leichte (RTOG Grad I) und sechs maessiggradige Nebenwirkungen (RTOG Grad II, meist Diarrhoe, Dysurie und Polyurie). Bei keinem Patienten musste die

  3. Personnel Dosimeters with Radiation Elements; Dosimetres Individuels Comportant des Elements Emetteurs; 0418 041d 0414 0418 0412 0418 0414 ; Dosimetros Individuales Provistos de Elementos Emisores

    Energy Technology Data Exchange (ETDEWEB)

    Hosemann, R.; Warrikhoff, H. F.H. [Fritz-Haber-Institut der Max-Planck-Gesellschaft, Berlin-Dahlem, Federal Republic of Germany (Germany)

    1965-06-15

    The radiation element is a vacuum diode, the electrodes of which emit a different charge of electrons per unit of irradiation. Since the electrons ejected leave one electrode with a high energy, the other electrode will be charged to proportionally high voltages without any auxiliary power. Accordingly these direct reading systems are called radiation elements. When measuring X- and y-rays, one electrode consists of lead, the other of carbon. The wavelength independence with regard to the r-unit was obtained by the electron-filtering method. The sensitivity is approximately 0.5 V/r {+-} 8% within the range from 80 keV to 1.25 MeV. (Full scale 200-2000 r either linear or quasi logarithm. ) When measuring slow and fast neutrons, the induced {beta}-activity of the electrodes charge the built-in electrometer. It is possible to measure both gamma radiation and neutrons in rem units with one instrument. The neutron sensitivity of a gamma element can be made definitely zero, but the gamma sensitivity of a neutron element presents some difficulties. The outstanding advantages of these instruments are: (1) Self-powered systems, always ready to function, unlimited storing time, no batteries or charging units; (2) Extremely low fading because of the use of vacuum and quartz for isolation; (3) Quantitative measurement of the highest attainable dose rates because of no recombination effects (vacuum) ; and (4) Either direct or indirect systems. The direct reading instrument contains the radiation element and the electrometer in the same vacuum vessel. There are no electrical contacts outside the instrument. Cylindrical and spherical designs of the element are preferable to other geometries. The outer dimensions of the instrument will be the same as those of the commonly used pen-type dosimeters. Each system contains a discharge switch and a control unit. (author) [French] L'element emetteur est constitue par une diode a vide dont les electrodes emettent des flux d

  4. The radiologist's responsibilities for the radiation protection of patients; Obligations du radiologue pour la radioprotection des patients

    Energy Technology Data Exchange (ETDEWEB)

    Etard, C. [Institut de Radioprotection et de Surete Nucleaire, 92 - Fontenay-aux-Roses (France)

    2010-11-15

    The obligations of the radiologist for the radiation protection of patients include a review of the appropriateness of the examination and optimization of the protocol. Both internal and external quality assurance programs are mandatory. The specific tasks and their frequency are defined by the AFSSAPS. The radiology report of procedures performed over radiosensitive regions must include the delivered dose. The imaging technique must be optimized based on published guidelines or law for the most frequent examinations. All radiologists should be familiar with radiation protection. Incidents should be reported to the Nuclear Safety Authority. (author)

  5. Application of new fast-electronic techniques to the determination of the exact moment of particle detection; Application des techniques nouvelles de l'electronique rapide a la determination de l'instant precis de detection d'une particule

    Energy Technology Data Exchange (ETDEWEB)

    Hesse, M [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1965-06-01

    Fluctuations in the time response of photomultipliers employed in scintillation counting are studied and experimentally checked. Statistical measurements of the output pulses show that the relative variance of the time fluctuations is minimum for the portion located around the bending point of the leading edge. A shaping circuit using this property is described. Experimental results are given, showing an improvement of the resolving time. (author) [French] Les fluctuations de la reponse temporelle des photomultiplicateurs, utilises dans les detecteurs a scintillations, sont etudiees et mesurees experimentalement. L'etude statistique des signaux de sortie montre que les fluctuations en temps presentent une variance relative minimale pour la region situee autour du point d'inflexion du front de montee. Un circuit de mise en forme utilisant cette propriete est decrit. Des resultats experimentaux sont donnes; ils montrent une amelioration sensible du pouvoir de resolution. (auteur)

  6. Normal tissue tolerance to external beam radiation therapy: Thyroid; Dose de tolerance des tissus sains: la thyroide

    Energy Technology Data Exchange (ETDEWEB)

    Berges, O.; Giraud, P. [Service d' oncologie-radiotherapie, hopital europeen Georges-Pompidou, universite Paris Descartes, 75 - Paris (France); Belkacemi, Y. [Service d' oncologie-radiotherapie, CHU Henri-Mondor, universite Paris 12, 94 - Creteil (France)

    2010-07-15

    The thyroid is the most developed endocrine gland of the body. Due to its anatomical location, it may be exposed to ionizing radiation in external radiotherapy involving head and neck. This review aims to describe the thyroid radiation disorders, probably under-reported in the literature, their risk factors and follow-up procedures. The functional changes after external beam radiation consists mainly of late effects occurring beyond 6 months, and are represented by the clinical and subclinical hypothyroidism. Its incidence is approximately 20 to 30% and it can occur after more than 25 years after radiation exposure. Hyperthyroidism and auto-immune manifestations have been described in a lesser proportion. The morphological changes consist of benign lesions, primarily adenomas, and malignant lesions, the most feared and which incidence is 0.35%. The onset of hypothyroidism depends of the total dose delivered to the gland, and the irradiated. Modern techniques of conformal radiotherapy with modulated intensity could improve the preservation of the thyroid, at the expense of the increase in low doses and the theoretical risk of secondary cancers. (authors)

  7. Effects of ionizing radiation and pretreatment with [D-Leu6,des-Gly10] luteinizing hormone-releasing hormone ethylamide on developing rat ovarian follicles

    International Nuclear Information System (INIS)

    Jarrell, J.; YoungLai, E.V.; McMahon, A.; Barr, R.; O'Connell, G.; Belbeck, L.

    1987-01-01

    To assess the effects of a gonadotropin-releasing hormone agonist, [D-Leu6,des-Gly10] luteinizing hormone-releasing hormone ethylamide, in ameliorating the damage caused by ionizing radiation, gonadotropin-releasing hormone agonist was administered to rats from day 22 to 37 of age in doses of 0.1, 0.4, and 1.0 microgram/day or vehicle and the rats were sacrificed on day 44 of age. There were no effects on estradiol, progesterone, luteinizing, or follicle-stimulating hormone, nor an effect on ovarian follicle numbers or development. In separate experiments, rats treated with gonadotropin-releasing hormone agonist in doses of 0.04, 0.1, 0.4, or 1.0 microgram/day were either irradiated or sham irradiated on day 30 and all groups sacrificed on day 44 of age. Irradiation produced a reduction in ovarian weight and an increase in ovarian follicular atresia. Pretreatment with the agonist prevented the reduction in ovarian weight and numbers of primordial and preantral follicles but not healthy or atretic antral follicles. Such putative radioprotection should be tested on actual reproductive performance

  8. Radiation exposure of radiologists during angiography: Dose measurements outside the lead apron; Die Strahlenexposition des Radiologen bei Angiographien: Dosismessungen ausserhalb der Bleischuerze

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, H. [Inst. fuer Diagnostische Radiologie, Duesseldorf Univ. (Germany); Przetak, C. [Inst. fuer Diagnostische Radiologie, Duesseldorf Univ. (Germany); Teubert, G. [Landesanstalt fuer Arbeitsschutz, Duesseldorf (Germany); Ewen, K. [Landesanstalt fuer Arbeitsschutz, Duesseldorf (Germany); Moedder, U. [Inst. fuer Diagnostische Radiologie, Duesseldorf Univ. (Germany)

    1995-02-01

    The aim of this study was to provide practical information to angiographers concerning radiation exposure to body parts not covered by lead aprons. Individual doses to the neck and hands of radiologists measured in micro-Sieverts were obtained during the course of 80 angiographies of various types. The number of diagnostic and interventional procedures, which might lead to exceeding permissible doses, have been calculated. Possibilities of estimating doses during angiography by means of parameters such as screening times were examined statistically. Especially with regard to the hands, estimations of the doses are insufficient (correlation r=0.21). Radiologists who undertake much angiographic and particularly interventional work may reach exposure levels requiring protective measures in addition to lead aprons. (orig.) [Deutsch] Ziel dieser Studie ist es, dem angiographierenden Radiologen praktische Anhaltspunkte zur Einschaetzung der Strahlenexposition der nicht von der Bleischuerze abgedeckten Koerperteile zu geben. Bei 80 Angiographien aus einem breiten klinischen Spektrum wurden Einzeldosen in Mikro-Sievert an Hals und Hand des Radiologen gemessen. Fuer bestimmte Gruppen von diagnostischen und interventionellen Angiographien wurde die Anzahl der Untersuchungen hochgerechnet, die zu einer Ueberschreitung der Grenzwerte fuehren koennte. Die Moeglichkeit einer Schaetzung der Dosis anhand von Parametern der Angiographie, wie z.B. der Durchleuchtungszeit, wurde korrelationsstatistisch geprueft. Besonders fuer die Haende ist eine Schaetzung unzureichend (r=0,21). Kontinuierlich und viel angiographiende Radiologen koennen im diagnostischen, aber eher noch im interventionellen Bereich eine Groessenordnung erreichen, die Vorsichtsmassnahmen oder Zusatzmessungen ausserhalb der Bleischuerze sinnvoll erscheinen laesst. (orig.)

  9. The electric charge of the aerosols under gamma radiation; La charge electrique des aerosols sous irradiation gamma

    Energy Technology Data Exchange (ETDEWEB)

    Gensdarmes, F.; Cetier, P.; Boulaud, D. [CEA/Saclay, Inst. de Protection et de Surete Nucleaire, IPSN/DPEA/SERAC, 91 - Gif-sur-Yvette (France); Renoux, A. [Paris-12 Univ., Lab. de Physique des Aerosols et de Transfert des Contaminations, 94 - Creteil (France)

    2000-07-01

    During a PWR type reactor accident, the gamma radiation may create a high ionized atmosphere. In such a situation the aerosols properties knowledge is useful to simulate the particles transport and deposit in the enclosed. The aim of this study is to determine the aerosol charges distribution in a high ionized medium, in function of the ionic properties of the medium. (A.L.B.)

  10. Normal tissue tolerance to external beam radiation therapy: Skin; Dose de tolerance des tissus sains: la peau et les phaneres

    Energy Technology Data Exchange (ETDEWEB)

    Ginot, A.; Doyen, J.; Hannoun-Levi, J.M.; Courdi, A. [Service d' oncologie-radiotherapie, centre Antoine-Lacassagne, 06 - Nice (France)

    2010-07-15

    Acute skin toxicity is frequent during radiation therapy and can lead to temporary arrest of the treatment. Chronic toxicity can occur and conduct to cosmetic problems. Alopecia is the most frequent toxicity concerning hair and is most of the time reversible. Several factors linked to patients influence skin toxicity, such as under-nutrition, old age, obesity, smoking, skin diseases, autoimmune diseases, failure of DNA reparation. Skin, hair and nail toxicities depend also on radiation schedule. Acute toxicity is greater when dose per fraction increases. Chronic and acute toxicities are more often when total dose increases. Under 45 Gy, the risk of severe skin toxicity is low, and begins above 50 Gy. Skin toxicity depends also on the duration of radiotherapy and split course schedules are associated with less toxicities. Irradiation surface seems to influence skin toxicity but interaction is more complex. Reirradiation is often feasible in case of cancer recurrence but with a risk of grade 3-4 toxicity above all in head and neck cancer. The benefit/risk ratio has to be always precisely evaluated. Permanent alopecia is correlated with the follicle dose. Modern techniques of radiation therapy allow to spare skin. (authors)

  11. Normal tissue tolerance to external beam radiation therapy: Cardiac structures; Dose de tolerance des tissus sains: le coeur

    Energy Technology Data Exchange (ETDEWEB)

    Doyen, J. [Service d' oncologie-radiotherapie, centre Antoine-Lacassagne, 06 - Nice (France); Giraud, P. [Universite Rene-Descartes Paris 5, 75 - Paris (France); Service d' oncologie-radiotherapie, hopital europeen Georges-Pompidou, 75 - Paris (France); Belkacemi, Y. [Faculte de medecine de Creteil, universite Paris 12, 94 - Creteil (France); Service d' oncologie-radiotherapie, CHU Henri-Mondor, 94 - Creteil (France)

    2010-07-15

    Radiation thoracic tumors may be associated with cardiac toxicity because of the central position of the heart in the thorax. The present review aims to describe the cardiotoxicity during radiotherapy of different tumor sites most associated with this complication and the risk factors of cardiotoxicity during radiation therapy. Medline literature searches were performed using the following cardiac - heart - radiotherapy - toxicity - cardiotoxicity - breast cancer - lymphoma. Cardiac toxicity after breast cancer and mediastinal lymphoma is the most reported radiation-induced complication. The most frequent clinical complications are pericarditis, congestive heart failure, and heart infarction. These events are mostly asymptomatic. Thus clinicians have to give particular attention to these complications. Anthracycline treatment is a major risk factor for additional cardiotoxicity during radiotherapy with a synergistic effect. Correction of cardiovascular risk is an important point of the prevention of heart complications. Total dose delivered to the planned target volume (PTV), the dose per fraction and the irradiated volume were correlated to the risk of cardiotoxicity. Volume of heart receiving 35 Gy must be inferior to 30% and dose per fraction should not exceed 2 Gy when dose of prescription exceeds 30 Gy. Maximum heart distance (maximal thickness of heart irradiated) must be less than 1 cm during irradiation of breast cancer. Modern irradiation techniques seem to be associated with a limited risk of heart complication. The use of anthracycline, other cardio-toxic chemotherapies and targeted therapies should incite for great caution by performing a careful treatment planning and optimisation. (authors)

  12. Modelling solar radiation interception in row plantation. 3. Application to a traditional vineyard; Modélisation de l’interception des rayonnements solaires dans une culture en rangs. 3. Application à une vigne traditionnelle

    Energy Technology Data Exchange (ETDEWEB)

    Sinoquet, H. [Institut National de la Recherche Agronomique, Pointe a Pitre (France); Valancogne, C.; Lescure, A.; Bonhomme, R.

    1992-07-01

    A previously described model of solar radiation interception was applied to a spatially discontinuous canopy: that of a traditional vineyard in which the classical terms of the radiative balance and the spatial distribution of the radiation transmitted to the soil were measured. Comparison of measured and simulated data gave satisfactory agreement for reflected radiation (fig 4), but major discrepancies appeared for mean transmitted radiation (fig 5). The use of small stationary sensors for measuring the transmitted radiation explains the latter observation, since most of the time they measured radiation received on the ground in the sunflecks or in the shaded area rather than mean radiation. This was verified by comparing the measured and simulated spatial distribution of transmitted radiation (figs 7, 8). Finally, the influence of the woody parts which were not taken into consideration in the model was clearly identified : it significantly reduced the transmission of incident radiation (fig 9), and to a greater degrees the closer the sensor was to the vegetation row. (author) [French] Un modèle d’interception du rayonnement solaire décrit précédemment est appliqué à un couvert spatialement discontinu : une vigne traditionnelle sur laquelle ont été mesurés les termes classiques du bilan radiatif et la distribution spatiale du rayonnement transmis au sol. La comparaison des mesures au modèle révèle un ajustement satisfaisant pour le rayonnement réfléchi (fig 4), mais assez médiocre pour le rayonnement transmis moyen (fig 5). Ceci est expliqué par l’utilisation de capteurs ponctuels qui, en raison de leur taille, mesurent plus souvent le rayonnement reçu au sol dans les taches de soleil ou les zones d’ombre qu’un rayonnement moyen. Ceci est vérifié en comparant les distributions mesurées et calculées du rayonnement transmis au sol (figs 7 et 8). Enfin, l’influence des parties ligneuses, non prise en compte dans le modèle, est

  13. Data processing in gamma spectrometry. Application to the decay schemes study; Traitement des informations en spectrometrie gamma application a l'etude de schemas de desintegration

    Energy Technology Data Exchange (ETDEWEB)

    Boulanger, J P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires, departement d' electronique generale, service d' instrumentation nucleaire

    1968-06-01

    The purpose of this thesis is the processing of the data issued from a gamma spectrometer, and its applications to the decay schemes study. The mathematical analysis of the full energy peaks, in connection with the very good resolution of semi-conductor detectors, leads to a very accurate determination of the energies. The resolution of complex spectra by the least squares method, completed by a spectra generating process, allows the calculation of branching ratios. Then, the handling of the two dimensional experiments permits the coincidence exam. For each of these methods, the calculation principle, then the systematics tests realized in order to prove their validity and to determine their application ranges as well as some experimental results appropriate to illustrate their possibilities, are presented. The energies of some nuclides, frequently used as standards have been thus measured and the decay schemes of {sup 134}Cs and {sup 110m}Ag determined precisely. (author) [French] Cette these est consacree aux methodes de traitement des informations issues d'un spectrometre {gamma}, et a leur application a l'etude des schemas de desintegration: l'analyse mathematique des pics d'absorption totale, conjuguee avec l'excellent pouvoir de resolution des detecteurs semi-conducteurs, conduit a une determination tres precise des energies. La decomposition des spectres complexes par la methode des moindres carres, completee par un procede de generation de spectres, autorise le calcul des rapports de branchement. Enfin le depouillement des experiences biparametriques permet l'examen des coincidences. Pour chacune de ces methodes, on expose le principe des calculs et les essais systematiques effectues afin d'eprouver leur validite et de definir leurs domaines d'application, ainsi que quelques resultats experimentaux propres a illustrer leurs possibilites. Les energies de quelques isotopes utilises couramment comme etalons ont ainsi ete mesurees, et les schemas de

  14. Study of gamma radiation between 0.1 and 1.0 MeV in the earth's atmosphere; Etude du rayonnement gamma entre 0,1 et 1 Mev dans l'atmosphere terrestre

    Energy Technology Data Exchange (ETDEWEB)

    Boclet, D [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-01-01

    The present work is devoted to some of the particular problems arising in the detection and localisation of sources of gamma radiation situated outside the earth's atmosphere. These weak sources can only be detected and localized if care is taken to eliminate gamma and particle radiations coming from other sources in the earth's atmosphere and in space. In order to separate the various sources of background noise, generally much stronger than the radiation under study, use is made of a directional detector whose characteristics are determined as described in the first part of the following report. The closest diffuse source considered is that constituted by the earth's atmosphere. Its detailed study will make it possible both to eliminate its effect when sources outside the earth are to be measured, and to predict the amount of secondary gamma radiation emitted by the same process in other celestial bodies, the moon in particular. This work considered in the 2. and 3. parts of the report. (author) [French] La presente etude est consacree a certains des problemes particuliers poses par la detection et la localisation des sources de rayonnement gamma situees hors de l'atmosphere terrestre. Ces sources faibles ne peuvent etre detectees et localisees que si l'on se protege des rayonnements gamma et particulaires provenant d'autres sources situees dans l'atmosphere terrestre et dans l'espace. Pour separer ces divers composants parasites, en general beaucoup plus intenses que le rayonnement a etudier, nous emploierons un detecteur directif dont nous determinons les caracteristiques dans la premiere partie de l'expose qui suit. La source diffuse la plus proche que nous considerons comme parasite est constituee par l'atmosphere terrestre. Son etude detaillee nous permettra d'une part de nous en proteger lorsque nous voudrons etudier les sources {gamma} extra-terrestres, d'autre part de prevoir le rayonnement gamma secondaire emis par le meme processus pour les autres corps

  15. Study of gamma radiation between 0.1 and 1.0 MeV in the earth's atmosphere; Etude du rayonnement gamma entre 0,1 et 1 Mev dans l'atmosphere terrestre

    Energy Technology Data Exchange (ETDEWEB)

    Boclet, D. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-01-01

    The present work is devoted to some of the particular problems arising in the detection and localisation of sources of gamma radiation situated outside the earth's atmosphere. These weak sources can only be detected and localized if care is taken to eliminate gamma and particle radiations coming from other sources in the earth's atmosphere and in space. In order to separate the various sources of background noise, generally much stronger than the radiation under study, use is made of a directional detector whose characteristics are determined as described in the first part of the following report. The closest diffuse source considered is that constituted by the earth's atmosphere. Its detailed study will make it possible both to eliminate its effect when sources outside the earth are to be measured, and to predict the amount of secondary gamma radiation emitted by the same process in other celestial bodies, the moon in particular. This work considered in the 2. and 3. parts of the report. (author) [French] La presente etude est consacree a certains des problemes particuliers poses par la detection et la localisation des sources de rayonnement gamma situees hors de l'atmosphere terrestre. Ces sources faibles ne peuvent etre detectees et localisees que si l'on se protege des rayonnements gamma et particulaires provenant d'autres sources situees dans l'atmosphere terrestre et dans l'espace. Pour separer ces divers composants parasites, en general beaucoup plus intenses que le rayonnement a etudier, nous emploierons un detecteur directif dont nous determinons les caracteristiques dans la premiere partie de l'expose qui suit. La source diffuse la plus proche que nous considerons comme parasite est constituee par l'atmosphere terrestre. Son etude detaillee nous permettra d'une part de nous en proteger lorsque nous voudrons etudier les sources {gamma} extra-terrestres, d'autre part de prevoir le rayonnement gamma

  16. Use of commercial VDMOSFETS in an electronic system subjected to radiation; Utilisation des VDMOSFETs commerciaux dans un systeme electronique soumis aux radiations

    Energy Technology Data Exchange (ETDEWEB)

    Picard, C.; Brisset, C.; Quittard, O.; Marceau, M.; Joffre, F. [CEA Saclay, Lab. d' Electronique et de Technologie de l' Informatique, LETI, 91 - Gif-sur-Yvette (France); Hoffmann, A.; Charles, J.P. [centre Lorrain d' Optique et Electronique des Solides, Supelec, 57 - Metz (France)

    1999-07-01

    This study explores the usefulness of pre-irradiation as a hardening technique for NMOS transistors. NMOS transistors have been exposed to Co-60 gamma radiation with a dose-rate of 10 krad(SiO{sub 2})/h. The pre-irradiation technique is based on 2 phenomena occurring when the polarization is negative or equals to 0: the weak shift and the saturation of the threshold voltage.

  17. Recent Developments in the Theory of Mechanisms in Radiation Chemical Processes; Developpements recents dans la theorie des mecanismes des reactions radiochimiques; Poslednie dostizheniya v teorii mekhanizmov radiatsionno-khimicheski kh protsessov; Adelantos recientes en la interpretacion teorica del mecanismo de los procesos radioquimicos

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, R. [U.K.A.E.A., Wantage Research Laboratory, Berks (United Kingdom)

    1963-11-15

    Recent developments in the mechanisms of radiation-initiated chemical reactions are reviewed. The role of ion molecule processes is reviewed, with particular reference to the radiation chemistry of methane. In this system, the existence of reactions of excited molecules, in addition to ionic processes is deduced. It is shown that, in the radiolysis of methane, unsaturated hydrocarbons play a considerable part in the mechanism of reaction. Developments in ionic polymerization and also polymerization under heterogenous conditions are reviewed. The importance of reactant purity, and also cleanliness of reaction vessels is discussed. The effect of an applied external potential in solid state polymerization is briefly reviewed. The importance of free-radical processes to radiation chemists is considered in the light of the Dow process for the production of ethyl bromide. (author) [French] L'auteur examine les resultats recents obtenus dans l'etude des mecanismes des reactions chimiques radio-induites. Il etudie l'importance des reactions ion-molecule, en considerant tout particulierement la radio-chimie due methane. Il en deduit qu'il existe dans ce systeme, outre les phenomenes ioniques, des reactions de molecules excitees. il montre que les hydrocarbures non satures jouent un role considerable dans la radiolyse du methane. Il passe en revue les resultats obtenus dans la polymerisation ionique ainsi que dans la polymerisation dans des conditions heterogenes. Il insiste sur l'importance de la purete des reactifs ainsi que sur la proprete des recipients. En meme temps, il examine brievement l'effet d'un potentiel exterieur sur la polymerisation a l'etat solide. Il signale l'importance radiochimique des reactions fondees sur des radicaux liebre, libres sous l'angle du procede Dow pour la production de bromure d'ethyle. (author) [Spanish] El autor examina los recientes progresos realizados en el estudio de los mecanismos de las reacciones quimicas radioinducidas. Sedala la

  18. The study of neutron propagation in natural uranium; Etude de la propagation des neutrons dans l'uranium naturel

    Energy Technology Data Exchange (ETDEWEB)

    Campan, J L; Clauzon, P P; Kirchner, B; Ribon, P; Zaleski, C P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    Fast exponential experiment. Experimental facilities are described; the experimental results obtained with the block of natural uranium are then presented. Detectors used were fission chambers, activation detectors and nuclear emulsions. One tries to explain the results, which are, then compared with theoretical values obtained by calculations based on diffusion theory. Measured spectrum (pseudo equilibrium) may be characterised by the following values: diffusion length: 95,25 {+-} 0,5; {sigma}{sub f}U{sub 235}/{sigma}{sub f}U{sub 238} : 230 {+-} 10, {sigma}{sub f}U{sub 235}/{sigma}{sub f}Np{sub 237} : 14 {+-} 0.5, {sigma}{sub f}U{sub 235}/{sigma}{sub f}U{sub 233} : 0.67 {+-} 0.03, {sigma}{sub f}U{sub 235}/{sigma}{sub f}Pu{sub 239} : 0.90 {+-} 0.05, {sigma}{sub f}U{sub 235}/{sigma}(ny) In : 230 {+-}10. (author) [French] Experience exponentielle rapide. Apres une description du dispositif experimental, on presente des resultats de mesures effectuees dans un massif d'uranium naturel. Les detecteurs utilises sont des chambres a fission, des detecteurs d'activation et des emulsions nucleaires. Une interpretation des resultats est donnee; ceux-ci sont compares a des valeurs theoriques obtenues par des calculs utilisant la theorie de la diffusion. Le spectre mesure (pseudo equilibre) peut etre caracterise par les valeurs suivantes: Longueur de diffusion: 95,25 {+-} 0,5; {sigma}{sub f}U{sub 235}/{sigma}{sub f}U{sub 238} : 230 {+-} 10, {sigma}{sub f}U{sub 235}/{sigma}{sub f}Np{sub 237} : 14 {+-} 0.5, {sigma}{sub f}U{sub 235}/{sigma}{sub f}U{sub 233} : 0.67 {+-} 0.03, {sigma}{sub f}U{sub 235}/{sigma}{sub f}Pu{sub 239} : 0.90 {+-} 0.05, {sigma}{sub f}U{sub 235}/{sigma}(ny) In : 230 {+-}10. (auteur)

  19. Use of proportional counter in X-Ray spectrometry between 5 and 100 keV. Application to the detection of fission products and to the determination of absolute X-Ray disintegration rates; Utilisation d'un compteur proportionnel en spectrometrie de rayons X entre 5 et 100 keV. Application a la detection des produits de fission et a la determination des taux d'emission X absolus

    Energy Technology Data Exchange (ETDEWEB)

    Cerf, J [Commissariat a l' Energie Atomique, Cadarache (France). Centre d' Etudes Nucleaires

    1969-07-01

    The measurement of electromagnetic radiations is difficult in the energy range 20-100 keV. We made suitable for this purpose a regular proportional counter, modifying both the nature and pressure of the gaseous mixture filling the detector volume. We selected the CPEN-SAIP counter, which is able to withstand such modifications. In the energy range considered, the counter is to be standardized with radioactive sources. Such standards were selected according to their disintegration schemes. We thus defined the conditions of use (resolution, yield) of the CPN counter, filled with an argon-methane mixture under a pressure of about 3 bars, in the energy range 5-100 keV. With such an equipment, we were able to measure the absolute disintegration rate for the X-rays of 133 Ba and 75 Se, then to perform the study of a mixed fission products sample. In the same way, we used xenon-based gaseous mixtures, in order to improve the detector yield; in the later case, we carefully examined the limitations introduced by the presence of many parasite rays emitted by the gas. We thus displayed in addition to the leakage peak, the fluorescence ray of the gas, whose origin is difficult to explain. (author) [French] La mesure des rayonnements electromagnetiques est difficile dans une bande d'energie comprise entre 20 et 100 keV environ. Nous avons rendu utilisable, a cet effet, un compteur proportionnel existant en modifiant la nature et la pression du melange gazeux constituant le volume detecteur. De par sa construction, le compteur CPXN, fabrique par les Etablissements S.A.I.P., rend ces experiences possibles. C'est pourquoi nous l'avons choisi. Dans le domaine d'energie consideree l'etalonnage du compteur necessite l'emploi de sources radioactives. Pour les preparer, nous sommes amenes a choisir les radio-nucleides utilisables par l'etude de leur schema de desintegration. Ainsi, nous avons defini les conditions d'utilisation (resolution, efficacite) du compteur CPNX rempli d

  20. Improvements in fast-neutron spectroscopy methods (1961); Amelioration des methodes de spectrometrie des neutrons rapides (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Cambou, F [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-02-15

    This research aimed at improving fast-neutron electronic detectors based on n-p elastic scattering. The first part concerns proportional counters; careful constructional methods have made it possible to plot mono-energetic neutron spectra in the range 700 keV - 3 MeV with a resolution of 7 per cent. The second part concerns scintillation counters: an organic scintillator and an inorganic scintillator covered with a thin layer of a scattering agent. An exact study of the types of scintillation has made it possible to develop efficient discriminator circuits. Different neutron spectra plotted in the presence of a strong gamma background are presented. The last part deals with the development of form discrimination methods for the study, in the actual beam, of the elastic scattering of 14.58 MeV electrons. With hydrogen, the distribution f ({phi}) of the recoil protons is f({phi}) = 1 + 0.034 cos {phi} + 0.042 cos{sup 2} {phi}. With tritium the scattering is strongly anisotropic; the curve representing the variation of the differential cross-section for the elastic scattering in the centre of mass system is obtained with a target containing 1 cm{sup 3} of tritium. (author) [French] Le travail a porte sur l'amelioration des detecteurs electroniques de neutrons rapides bases sur la diffusion elastique n-p. La premiere partie est relative aux compteurs proportionnels; des methodes soignees de fabrication ont permis des traces de spectres de neutrons monoenergetiques dans le domaine 700 keV - 3 MeV avec une resolution de 7 pour cent. La deuxieme partie est relative au compteur a scintillations; scintillateur organique et scintillateur mineral recouvert d'un diffuseur mince. Une etude precise des formes de scintillations a permis la mise au point de circuits discriminateurs efficaces. Differents spectres de neutrons traces en presence d'un fond gamma intense sont presentes. La derniere partie est relative a la mise en oeuvre des methodes de discrimination de forme pour l

  1. Health and biological effects of non-ionizing radiations; Effets biologiques et sanitaires des rayonnements non ionisants

    Energy Technology Data Exchange (ETDEWEB)

    De Seze, R.; Souques, M.; Aurengo, A.; Bach, V.; Burais, N.; Cesarini, J.P.; Cherin, A.; Decobert, V.; Dubois, G.; Hours, M.; Lagroye, I.; Leveque, Ph.; Libert, J.P.; Lombard, J.; Loos, N.; Mir, L.; Perrin, A.; Poulletier De Gannes, F.; Thuroczy, G.; Wiart, J.; Lehericy, St.; Pelletier, A.; Marc-Vergnes, J.P.; Douki, Th.; Guibal, F.; Tordjman, I.; Gaillot de Saintignon, J.; Collard, J.F.; Scoretti, R.; Magne, I.; Veyret, B.; Katrib, J.

    2011-07-01

    This document gathers the slides of the available presentations given during this conference day on the biological and health effects of non-ionizing radiations. Sixteen presentations out of 17 are assembled in the document and deal with: 1 - NMR: biological effects and implications of Directive 2004/40 on electromagnetic fields (S. Lehericy); 2 - impact of RF frequencies from mobile telephone antennas on body homeostasis (A. Pelletier); 3 - expression of stress markers in the brain and blood of rats exposed in-utero to a Wi-Fi signal (I. Lagroye); 4 - people exposure to electromagnetic waves: the challenge of variability and the contribution of statistics to dosimetry (J. Wiart); 5 - status of knowledge about electromagnetic fields hyper-sensitivity (J.P. Marc-Vergnes; 6 - geno-toxicity of UV radiation: respective impact of UVB and UVA (T. Douki); 7 - National day of prevention and screening for skin cancers (F. Guibal); 8 - UV tan devices: status of knowledge about cancer risks (I. Tordjman, and J. Gaillot de Saintignon); 9 - modulation of brain activity during a tapping task after exposure to a 3000 {mu}T magnetic field at 60 Hz (M. Souques and A. Legros); 10 - calculation of ELF electromagnetic fields in the human body by the finite elements method (R. Scoretti); 11 - French population exposure to the 50 Hz magnetic field (I. Magne); 12 - LF and static fields, new ICNIRP recommendations: what has changed, what remains (B. Veyret); 13 - risk assessment of low energy lighting systems - DELs and CFLs (J.P. Cesarini); 14 - biological effects to the rat of a chronic exposure to high power microwaves (R. De Seze); 15 - theoretical and experimental electromagnetic compatibility approaches of active medical implants in the 10-50 Hz frequency range: the case of implantable cardiac defibrillators (J. Katrib); French physicians and electromagnetic fields (M. Souques). (J.S.)

  2. Radiative modeling and characterization of aerosol plumes hyper-spectral imagery; Modelisation radiative et caracterisation des panaches d'aerosols en imagerie hyperspectrale

    Energy Technology Data Exchange (ETDEWEB)

    Alakian, A

    2008-03-15

    This thesis aims at characterizing aerosols from plumes (biomass burning, industrial discharges, etc.) with hyper-spectral imagery. We want to estimate the optical properties of emitted particles and also their micro-physical properties such as number, size distribution and composition. To reach our goal, we have built a forward semi-analytical model, named APOM (Aerosol Plume Optical Model), which allows to simulate the radiative effects of aerosol plumes in the spectral range [0,4-2,5 {mu}m] for nadir viewing sensors. Mathematical formulation and model coefficients are obtained from simulations performed with the radiative transfer code COMANCHE. APOM is assessed on simulated data and proves to be accurate with modeling errors between 1% and 3%. Three retrieval methods using APOM have been developed: L-APOM, M-APOM and A-APOM. These methods take advantage of spectral and spatial dimensions in hyper-spectral images. L-APOM and M-APOM assume a priori knowledge on particles but can estimate their optical and micro-physical properties. Their performances on simulated data are quite promising. A-APOM method does not require any a priori knowledge on particles but only estimates their optical properties. However, it still needs improvements before being usable. On real images, inversion provides satisfactory results for plumes above water but meets some difficulties for plumes above vegetation, which underlines some possibilities of improvement for the retrieval algorithm. (author)

  3. Radiation

    International Nuclear Information System (INIS)

    2013-01-01

    The chapter one presents the composition of matter and atomic theory; matter structure; transitions; origin of radiation; radioactivity; nuclear radiation; interactions in decay processes; radiation produced by the interaction of radiation with matter

  4. Target volumes in gastric cancer radiation therapy; Les volumes-cibles de la radiotherapie des adenocarcinomes gastriques

    Energy Technology Data Exchange (ETDEWEB)

    Caudry, M.; Maire, J.P. [Hopital Saint Andre, Service de Cancerologie, 33 - Bordeaux (France); Ratoanina, J.L.; Escarmant, P. [Hopital Clarac, Service de Radiotherapie et de Cancerologie, 97 - Fort de France (France)

    2001-10-01

    The spread of gastric adenocarcinoma may follow three main patterns: hemato-genic, lymphatic and intraperitoneal. A GTV should be considered in preoperative or exclusive radiation therapy. After non-radical surgery, a 'residual GTV' will be defined with the help of the surgeon. The CTV encompasses three intricated volumes. a) A 'tumor bed' volume. After radical surgery, local recurrences appear as frequent as distant metastases. The risk depends upon the depth of parietal invasion and the nodal status. Parietal infiltration may extend beyond macroscopic limits of the tumor, especially in dinitis plastica. Therefore this volume will include: the tumor and the remaining stomach or their 'bed of resection', a part of the transverse colon, the duodenum, the pancreas and the troncus of the portal vein. In postoperative RT, this CTV also includes the jejuno-gastric or jejuno-esophageal anastomosis. b) A peritoneal volume. For practical purposes, two degrees of spread must be considered: (1) contiguous microscopic extension from deeply invasive T3 and T4 tumors, that remain amenable to local sterilization with doses of 45-50 Gy, delivered in a CTV including the peritoneal cavity at the level of the gastric bed, and under the parietal incision; (2) true 'peritoneal carcinomatosis', with widespread seeds, where chemotherapy (systemic or intraperitoneal) is more appropriate. c) A lymphatic volume including the lymph node groups 1 to 16 of the Japanese classification. This volume must encompass the hepatic pedicle and the splenic hilum. In proximal tumors, it is possible to restrict the lover part of the CTV to the lymphatic volume, and therefore to avoid irradiation of large intestinal and renal volumes. In distal and proximal tumors, involvement of resection margins is of poor prognosis -a radiation boost must be delivered at this level. The CTV in tumors of the cardia should encompass the lover part of the thoracic esophagus and the

  5. Individual sensitivity to radiations and DNA repair proficiency: the comet assay contribution; Sensibilite individuelle aux radiations et reparation de l`ADN: apport du test des cometes

    Energy Technology Data Exchange (ETDEWEB)

    Alapetite, C. [Institut Curie, 75 - Paris (France)

    1998-09-01

    Some are hereditary syndromes demonstrate high cancer risk and hypersensitivity in response to exposures to agents such as ultraviolet or ionising radiation, and are characterized by a defective processing of DNA damage. They highlight the importance of the individual risk associated to exposures. The comet assay, a simple technique that detects DNA strand breaks, requires few cells and allows examination of DNA repair capacities in established cell lines, in blood samples or biopsies. The assay has been validated on cellular systems with known repair defects such as xeroderma pigmentosum defective in nucleotide excision repair, on mutant rodent cell lines defective in DNA single strand breaks rejoining (XRCC5/Ku80 and XRCC7/DNAPKcs) (neutral conditions). This assay does not allow to distinguish a defective phenotype in ataxia telangiectasia cells. It shows in homozygous mouse embryo fibroblasts Brca2-/- an impaired DNA double strand break rejoining. Simplicity, rapidity and sensitivity of the alkaline comet assay allow to examine the response of lymphocytes. It has been applied to the analysis of the role of DNA repair in the pathogenesis of collagen diseases, and the involvement of individual DNA repair proficiency in the thyroid tumorigenesis induced in some patients after therapeutic irradiation at childhood has been questioned. Preliminary results of these studies suggest that this type of approach could help for adapting treatment modalities and surveillance in subgroups of patients defective in DNA repair process. It could also have some incidence in the radioprotection field. (author)

  6. A new detector for the measurement of neutron flux in nuclear reactors; Nouvelle methode de mesure des flux de neutrons dans les reacteurs atomiques

    Energy Technology Data Exchange (ETDEWEB)

    Koch, L; Labeyrie, J; Tarassenko, S [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    The detector described is designed for the instantaneous measurement of thermal neutron fluxes, in the presence of high {gamma} ray activity; this detector can withstand temperatures as high as 500 deg. C. It is based on the following principle: radioactive atoms resulting from heavy-nucleus fission are carried by a gas flow to a detector recording their {beta} and {gamma} disintegration. Thermal neutron fluxes as low as few neutrons per cm{sup 2} per second can be measured. This detector may be used to control a nuclear reactor, to plot the thermal flux distribution with an excellent definition (1 mm{sup 2}) for fluxes higher than 10{sup 8} n/cm{sup 2}/s. The time response of the system to a sharp variation of flux is limited, in case of large fluxes, to the transit time of the gas flow between the fission product emitter and the detector; of the order of one tenth of a sec per meter of piping. The detector may also be applied for spectroscopy of fission products eider than 0,1 s. (author)Fren. [French] On decrit un appareil permettant la mesure instantanee des flux de neutrons thermiques accompagnes de flux intenses de rayons {gamma} et situes dans des enceintes pouvant etre portees a des temperatures superieures a 500 deg. C. On utilise la radioactivite des atomes resultant de la fission des noyaux lourds; ces atomes sont entraines par un courant gazeux vers un detecteur de radioactivite qui enregistre leurs desintegrations {beta} et {gamma}. On peut mesurer des flux partir de quelques neutrons thermiques par cm{sup 2} et par seconde. L'appareil permet de suivre la puissance d'un reacteur atomique, de tracer des cartes de densite de neutrons avec une tres bonne definition (1 mm{sup 2}) dans le cas de flux superieurs a 10{sup 8} cm{sup 2}/s. Le temps de reponse du systeme a une variation du flux de neutrons est limite, poes flux importants, par le temps de transit du gaz entre l'emetteur de produits de fission et le detecteur: soit quelques dizaines de

  7. Radiation protection for humans and society in tomorrow's Europe. Joint meeting of OeVS (Oesterreichischer Verband fuer Strahlenschutz) and FS (Fachverband fuer Strahlenschutz). 33. FS annual meeting; Strahlenschutz fuer Mensch und Gesellschaft im Europa von morgen. Gemeinsame Tagung des oesterreichischen Verbandes fuer Strahlenschutz und des Fachverbandes fuer Strahlenschutz e.V.. 33. Jahrestagung des FS

    Energy Technology Data Exchange (ETDEWEB)

    Mueck, K.; Hefner, A.; Vana, N. (eds.)

    2001-07-01

    More than 100 papers on the following topics were presented at the meeting: Radiation monitoring and dosimetry, radiation protection, natural radioactivity, radiation protection and environment, radiation protection in occupational radiation exposure, radiation protection of patients, non-ionizing radiations, incidents and accidents, radiation hazards and socioeconomic aspects, standards, risk assessment, sociological and ethic aspects. (MG)

  8. Effects of the new radiation protection act on the radiation protection register and the monitoring of occupational radiation exposure; Auswirkungen des neuen Strahlenschutzgesetzes auf das Strahlenschutzregister und die berufliche Strahlenueberwachung

    Energy Technology Data Exchange (ETDEWEB)

    Frasch, G. [Bundesamt fuer Strahlenschutz (Germany)

    2016-07-01

    The implementation of DIRECTIVE 2013/59 / EURATOM (EURATOM Basic Safety Standards) is via the new radiation protection law and brings in the monitoring of occupational radiation among others two significant new features and changes: - Introduction of a unique personal identifier, - update of the occupational categories. Both require technical and organizational changes in the data transmission of the licensees to the dosimetry services and the radiation protection register.

  9. Thermal neutron flux measurements using neutron-electron converters; Mesure de flux de neutrons thermiques avec des convertisseurs neutrons electrons

    Energy Technology Data Exchange (ETDEWEB)

    Le Meur, R; Lecomte, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1968-07-01

    The operation of neutron-electron converters designed for measuring thermal neutron fluxes is examined. The principle is to produce short lived isotopes emitting beta particles, by activation, and to measure their activity not by extracting them from the reactor, but directly in the reactor using the emitted electrons to deflect the needle of a galvanometer placed outside the flux. After a theoretical study, the results of the measurements are presented; particular attention is paid to a new type of converter characterized by a layer structure. The converters are very useful for obtaining flux distributions with more than 10{sup 7} neutrons cm{sup -2}*sec{sup -1}. They work satisfactorily in pressurized carbon dioxide at 400 Celsius degrees. Some points still have to be cleared up however concerning interfering currents in the detectors and the behaviour of the dielectrics under irradiation. (authors) [French] On examine le fonctionnement de convertisseurs neutrons electrons destines a des mesures de flux de neutrons thermiques. Le principe est de former par activation des isotopes a periodes courtes et a emission beta et de mesurer leur activite non pas en les sortant du reacteur, mais directement en pile, utilisant les electrons emis pour faire devier l'aiguille d'un galvanometre place hors flux. Apres une etude theorique, on indique des resultats de mesures obtenus, en insistant particulierement sur un nouveau type de convertisseur, caracterise par sa structure stratifiee. Les convertisseurs sont tres interessants pour tracer, des cartes de flux a partir de 10{sup 7} neutrons cm{sup -2}*s{sup -1}. Ils sont utilisables pour des flux de 10{sup 14} neutrons cm{sup -2}*s{sup -1}. Ils fonctionnent correctement dans du gaz carbonique sous pression a 400 C. Des points restent cependant a eclaircir concernant les courants parasites dans les detecteurs et le comportement des dielectriques pendant leur irradiation. (auteur)

  10. Etude des phenomenes dynamiques ultrarapides et des caracteristiques impulsionnelles d'emission terahertz du supraconducteur YBCO

    Science.gov (United States)

    Savard, Stephane

    Les premieres etudes d'antennes a base de supraconducteurs a haute temperature critique emettant une impulsion electromagnetique dont le contenu en frequence se situe dans le domaine terahertz remontent a 1996. Une antenne supraconductrice est formee d'un micro-pont d'une couche mince supraconductrice sur lequel un courant continu est applique. Un faisceau laser dans le visible est focalise sur le micro-pont et place le supraconducteur dans un etat hors-equilibre ou des paires sont brisees. Grace a la relaxation des quasiparticules en surplus et eventuellement de la reformation des paires supraconductrices, nous pouvons etudier la nature de la supraconductivite. L'analyse de la cinetique temporelle du champ electromagnetique emis par une telle antenne terahertz supraconductrice s'est averee utile pour decrire qualitativement les caracteristiques de celle-ci en fonction des parametres d'operation tels que le courant applique, la temperature et la puissance d'excitation. La comprehension de l'etat hors-equilibre est la cle pour comprendre le fonctionnement des antennes terahertz supraconductrices a haute temperature critique. Dans le but de comprendre ultimement cet etat hors-equilibre, nous avions besoin d'une methode et d'un modele pour extraire de facon plus systematique les proprietes intrinseques du materiau qui compose l'antenne terahertz a partir des caracteristiques d'emission de celle-ci. Nous avons developpe une procedure pour calibrer le spectrometre dans le domaine temporel en utilisant des antennes terahertz de GaAs bombarde aux protons H+ comme emetteur et detecteur. Une fois le montage calibre, nous y avons insere une antenne emettrice dipolaire de YBa 2Cu3O7-delta . Un modele avec des fonctions exponentielles de montee et de descente du signal est utilise pour lisser le spectre du champ electromagnetique de l'antenne de YBa 2Cu3O7-delta, ce qui nous permet d'extraire les proprietes intrinseques de ce dernier. Pour confirmer la validite du modele

  11. The Role of Free-Radicals in the Radiation Vulcanizing of Elastomers; Role des radicaux libres dans la vulcanisation radiochimique des elastomeres; O roli svobodnykh radikalov v protsesse radiatsionnoj vulkanizatsii ehlastomerov; Papel de los radicales libres en la radiovulcanizacion de los elastomeros

    Energy Technology Data Exchange (ETDEWEB)

    Kuz' minskij, A. S.; Fedoseeva, T. E.; Chertkova, V. F.

    1963-11-15

    The ability of certain polymers to form cross-links under the action of ionizing radiation has recently been applied in the industrial vulcanization of rubber products. The formation mechanism of a three-dimensional network under the action of radiation is receiving considerable attention from research workers. So far, however, the initial and intermediate stages of the irradiation reactions, leading to the linking of the molecular chains and connected with the formation and destruction of free-radicals, ion radicals and excited molecules, have not been sufficiently investigated. The study of the structure and properties of such fragments has become possible only with the development and wide-spread use of the electron-paramagnetic resonance (EPR) technique, through which information about the structure and properties of paramagnetic particles can be directly obtained. By investigating the recombination process of free-radicals in linear polymers we can get directly at the mechanism of radiation vulcanization. There has recently been a tendency to use ionizing radiation for the de-vulcanization of sulphur vulcanized rubbers, since the combination of sulphur and carbon cross-links gives maximum Improvement in the physico-mechanical properties of products; hence, in this connection is there the interest in studying the kinetic properties of free-radicals'in polymers with a developed space structure. The recombination processes of the free-radicals produced by gamma irradiation are examined in detail in relation to the structural properties of polymer, i.e. to the orientation and internal mobility of molecular chains. In highly elastic polymers of the rubber type, characterized by high internal mobility of the chains and low intermolecular bond energy, the actual recombinations of free-radicals at temperatures above Tg occur at very high speed. The concentration of radicals in rubber samples, irradiated in liquid nitrogen, diminishes on warming up to +20{sup o}C by 1

  12. Radiation Resistance of Enzymes in Foods Irradiated Against Microbial Damage; Radioresistance des Enzymes dans les Denrees Alimentaires Irradiees pour les Proteger Contre les Alterations Dues a des Bacteries; Radiatsionnaya ustojchivost' ehnzimov v pishchevykh produktakh,obluchennykh protiv vrednogo vozdejstviya mikrobov; Radiorresistencia de las Enzimas en los Alimentos Irradiados

    Energy Technology Data Exchange (ETDEWEB)

    Vas, K. [Joint FAO/IAEA Division of Atomic Energy in Agriculture, International Atomic Energy Agency, Vienna (Austria)

    1966-11-15

    Most enzymes which play a role in the storage, processing and preservation of food are rather resistant to ionizing radiations. Generally speaking, their in situ radio-resistance is about an order of magnitude higher than that of the microorganisms causing spoilage or public health hazards. Thus, radiation doses adequate to microbiological stabilization, and at present considered just feasible economically, are insufficient to prevent enzymatic deterioration. Many attempts have already been made to inactivate enzymes in food by radiation but, judging by the relative failure of most of these efforts, much more background information seems to be necessary to deal with the problem on a more rational basis. To date, work in radiation enzymology has, to a large extent, been carried out in systems of medical interest, generally giving results not readily transposable to food systems. In the past (a) the mechanism of inactivation, as well as the roles of (b) enzyme concentration, (c) water activity of the medium, (d) oxygen concentration, (e) pH and (f) temperature, have been studied most intensively. This is reviewed in the paper. Since, in the majority of the reported experiments, the degree of purity of the enzyme has not been stated (or known, for that matter to the authors themselves), and since, on the other hand, radio-modifying substances are known to exert a decisive influence on the radiation inactivation of enzymes, it is felt that much more work is still needed on radio-protectors and radiation sensitizers in combination with highly-purified enzymes. The usual great radio-sensitivity of high-purity enzymes and the contrasting extreme resistance of enzymes in the tissues and in their unpurified extracts certainly indicate the need for finding the reasons for this difference in order to facilitate possibly a rational approach of controlling enzyme activity in food irradiation. In this way, perhaps some novel ''combination method'' can eventually be developed in

  13. Modification of non metallic materials under the influence of the radiation and thermal retrogradation of these modifications; Modification de materiaux non metalliques sous l'influence des rayonnements et retrogradation thermique de ces modifications

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, G; Perio, P; Gigon, J; Tournarie, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1955-07-01

    The action of the radiation on solids constitute an extremely vast domain of study, which the CEA hardly begins. There is not a very long time, indeed, that we have relatively intense fluxes (6.10{sup 12} thermal neutrons by cm{sup 2}.s{sup -} {sup 1} in the center of the reactor core of Saclay). Materials submitted to radiations, were followed by the evolution of a certain number of physical properties. The study of thermal retrogradation, at moderate temperature, of the modifications provoked by the irradiation were also followed. We will limit, in this report, to expose our experiences on graphite and lithium fluoride. (M.B.) [French] L'action des rayonnements sur les solides constitue un domaine extremement vaste dont l'etude, au Commissariat a l'Energie Atomique, commence a peine. Il n'y a pas tres longtemps, en effet, que nous disposons de flux relativement intenses (6.10{sup 12} neutrons thermiques par cm{sup 2}.s{sup -1} au centre de la pile de Saclay). Dans les materiaux soumis au rayonnement nous suivons l'evolution d'un certain nombre de proprietes physiques et nous etudions la retrogradation thermique, a temperature moderee, des modifications provoquees par l'irradiation. Nous nous bornerons ici a exposer nos experiences sur le graphite et le fluorure de lithium. (M.B.)

  14. Study and industrial applications of the external slowing-down {beta}{sup -} radiation of the yttrium - 90; Etude et applications industrielles du rayonnement de freinage externe des {beta}{sup -} de l'yttrium - 90

    Energy Technology Data Exchange (ETDEWEB)

    Leveque, P; Martinelli, P; Chauvin, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1955-07-01

    Inelastic scattering of the {beta}{sup -} particles on the nucleus gives place to the emission of a X-ray Bremsstrahlung radiation. In view of possible industrial applications, we studied the slowing-down radiation of {sup 90}(Sr + Y) sources in various materials. This pure {beta}{sup -} emitter of long period is in the fission products of uranium. Among of the industrial applications, these sources of weak X-rays energy can be used for the radiography of thin pieces, for measuring the thickness, or for the analysis by fluorescence. (M.B.) [French] La diffusion inelastique des particules {beta}{sup -} sur les noyaux donne lieu a l'emission d'un rayonnement X de freinage. En vue de possibles applications industrielles, nous avons etudie le rayonnement de freinage des sources {sup 90}(Sr + Y) dans divers materiaux. Cet emetteur {beta}{sup -} pur a longue periode se trouve dans les produits de fission de l'uranium. Parmi les applications industrielles a l'etude, ces sources de rayons X de faible energie peuvent etre utilisees pour la radiographie de pieces minces, la mesure d'epaisseurs, ou encore pour l'analyse par fluorescence. (M.B.)

  15. Radiation Safety Report 2003, Forschungszentrum Rossendorf e.V. and Verein fuer Kernverfahrenstechnik und Analytik Rossendorf e.V.; Jahresbericht Strahlenschutz 2003 des Forschungszentrums Rossendorf e.V. und des Vereins fuer Kernverfahrenstechnik und Analytik Rossendorf e.V.

    Energy Technology Data Exchange (ETDEWEB)

    Sahre, P. (comp.)

    2004-03-01

    The annual report contains information and measured data obtained with the routine monitoring and measuring activities performed in 2003 at the VKTA and the nuclear research center, FZR, referring to health physics measurements and individual dosimetry of internal and external personnel, and ambient radioactivity monitoring in the area of the two facilities. [German] Der Jahresbericht informiert ueber die Taetigkeiten und die Messwerte des Jahres 2003, die im VKTA und FZR routinemaessig durchgefuehrt und gemessen wurden in den Bereichen: 1. Personenueberwachung, berufliche Strahlenexposition von internen Mitarbeitern oder externem Personal von Fremdfirmen. 2. Strahlenschutzumgebungsueberwachung. (orig./AJ)

  16. Studies on the rice seed (Oryza sativa) sensitivity to gama radiation, neutrons di-enthyl sulphate (DES) and sodium azide (SA)

    International Nuclear Information System (INIS)

    Guimaraes, E.P.

    1978-04-01

    Dry rice seeds of 'Dourado Precoce' variety were treated with gama-rays, thermal and fast neutrons, di-ethyl sulphate (DES) and sodium azide (SA). Biologial effects on survival, seedling height, plant fertility and chlorophy 11 mutation frequency were studied in the M 1 generation. The data obtained were analysed by 'independent test'. Survival was not affected by increased gama ray dosage, but by increased DES and SA dosages, as well as by SA treatments with increased solution acidity for seeds pretreated in distilled water. Seedling height was decreased with the increase of gama-ray dosage, DES concentration. SA acidity and concentration. Plant fertility was reduced drastically with higher gama-ray and neutron dosages and with high SA acidity and concentrations. The maximum chlorophy 11 mutation frequency was obtained in the SA treatment. Seeds pretreated with distilled water showed larger physiological damages in the SA treatments and higher mutation frequencies. Regarding chlorophyll mutation frequency, thermal neutrons were more efficient than gama-rays. SA was the most efficient mutagen used . DES showed lower physiological damages in the M 1 plants, but did not induce mutations in the used conditions [pt

  17. Count rate balance method of measuring sediment transport of sand beds by radioactive tracers; Methode du bilan des taux de comptage d'indicateurs radioactifs pour la determination du debit de charriage des lits sableux

    Energy Technology Data Exchange (ETDEWEB)

    Sauzay, G [Commissariat a l' Energie Atomique, 91 - Saclay (France). Centre d' Etudes Nucleaires

    1967-11-01

    Radioactive tracers are applied to the direct measurement of the sediment transport rate of sand beds. The theoretical measurement formula is derived: the variation of the count rate balance is inverse of that of the transport thickness. Simultaneously the representativeness of the tracer is critically studied. The minimum quantity of tracer which has to be injected in order to obtain a correct statistical definition of count rate given by a low number of grains 'seen' by the detector is then studied. A field experiment was made and has let to study the technological conditions for applying this method: only the treatment of results is new, the experiment itself is carried out with conventional techniques applied with great care. (author) [French] Les indicateurs radioactifs sont appliques a la mesure directe du debit de charriage des lits sableux. On etablit la formule theorique de mesure: le bilan des taux de comptage varie en sens inverse de l'epaisseur de charriage. Parallelement on fait une etude critique de la representativite de l'indicateur, puis on determine la quantite minimale de traceur qu'il faut immerger pour que les taux de comptage fournis pour un faible nombre de grains 'vus' par le detecteur aient une definition statistique correcte. Une experience de terrain a permis d'etudier les conditions technologiques de cette methode: seul le depouillement des resultats est nouveau. L'experimentation in-situ se fait suivant les procedes classiques avec un tres grand soin. (auteur)

  18. ANALYSE DES PERCEPTIONS LOCALES ET DES FACTEURS ...

    African Journals Online (AJOL)

    AISA

    1Faculté des Sciences Agronomiques (FSA), Université d'Abomey-Calavi (UAC), 01 BP 526 Cotonou Bénin. Email : cgbemavo@yahoo.fr. 2Institut National des Recherches Agricoles du Bénin, Centre de Recherches Agricoles d'Agonkanmey (CRA-A),. Laboratoire des Sciences du Sol, Eau et Environnement (LSSEE).

  19. Radiation injuries. Comment on the statement of the consultant. 2. enl. ed.; Schaeden durch Strahlung. Stellungnahme zu den Ausfuehrungen des Gutachters

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-11-01

    The report is a comment on the court hearing January 6, 2012 concerning the contamination and incorporation by ionizing radiation near radar equipment of the German Federal Armed forces, including a comment on deficiencies of the consultant's statement. The following issues are covered: biophysical and biochemical radiation effects, the relative biological efficacy, ionizing radiation effects on human health, acute radiation syndromes, stochastic effects, radiation accidents and early diagnosis. The report includes a variety of protocols and correspondence on the case.

  20. Register of legislative and regulatory dispositions relative to the radiation protection of the population and workers against the dangers of ionizing radiations; Recueil des dispositions legislatives et reglementaires concernant la protection de la population et des travailleurs contre les dangers des rayonnements ionisants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-12-15

    This collection of legislative arrangements concerns the protection of population and workers against the risks of ionizing radiations. Each chapter is divided in two parts: a legislative part and a statutory or regulation part. We find the different chapters in relation with protection of populations, protection of workers, public health and labour laws. (N.C.)

  1. Effets des electrons secondaires sur l'ADN

    Science.gov (United States)

    Boudaiffa, Badia

    Les interactions des electrons de basse energie (EBE) representent un element important en sciences des radiations, particulierement, les sequences se produisant immediatement apres l'interaction de la radiation ionisante avec le milieu biologique. Il est bien connu que lorsque ces radiations deposent leur energie dans la cellule, elles produisent un grand nombre d'electrons secondaires (4 x 104/MeV), qui sont crees le long de la trace avec des energies cinetiques initiales bien inferieures a 20 eV. Cependant, il n'y a jamais eu de mesures directes demontrant l'interaction de ces electrons de tres basse energie avec l'ADN, du principalement aux difficultes experimentales imposees par la complexite du milieu biologique. Dans notre laboratoire, les dernieres annees ont ete consacrees a l'etude des phenomenes fondamentaux induits par impact des EBE sur differentes molecules simples (e.g., N2, CO, O2, H2O, NO, C2H 4, C6H6, C2H12) et quelques molecules complexes dans leur phase solide. D'autres travaux effectues recemment sur des bases de l'ADN et des oligonucleotides ont montre que les EBE produisent des bris moleculaires sur les biomolecules. Ces travaux nous ont permis d'elaborer des techniques pour mettre en evidence et comprendre les interactions fondamentales des EBE avec des molecules d'interet biologique, afin d'atteindre notre objectif majeur d'etudier l'effet direct de ces particules sur la molecule d'ADN. Les techniques de sciences des surfaces developpees et utilisees dans les etudes precitees peuvent etre etendues et combinees avec des methodes classiques de biologie pour etudier les dommages de l'ADN induits par l'impact des EBE. Nos experiences ont montre l'efficacite des electrons de 3--20 eV a induire des coupures simple et double brins dans l'ADN. Pour des energies inferieures a 15 eV, ces coupures sont induites par la localisation temporaire d'un electron sur une unite moleculaire de l'ADN, ce qui engendre la formation d'un ion negatif transitoire

  2. Disinfestation of Dried Figs by Gamma Radiation; Desinsectation des figues seches par les rayons gamma; Dezinfestatsiya sushenogo inzhira s pomoshch'yu gamma-izlucheniya'; Desinfestacion de higos secos mediante rayos gamma

    Energy Technology Data Exchange (ETDEWEB)

    Papadopoulou, C. P. [Department of Biology, Democritus Nuclear Research Centre, Aghia Paraskevi, Attica (Greece)

    1963-09-15

    Research has been carried on for many years on the disinfestation of stored agricultural products. Recently gamma radiation has been successfully applied in such investigations. Dried figs are among the main export products of Greece. Serious damage is caused by insect attack each year. The research work aimed at: (1) Determining the doses of radiation required to destroy certain species of insects attacking dried figs at their various stages of development, or to destroy their eggs and thus prevent reproduction; and (2) Determining the physical and chemical changes of the texture of dried figs caused by radiation. Studies have been made on the following species: Plodia interpunctella, Ephestia cautella, Carpophilus hemipterous, Oryzaephilus surinamensis and Lasioderma serricorne. The optimum doses required are discussed. At these doses, irradiation damage does not become apparent in the texture of the figs. (author) [French] Des recherches sur la desinsectation des produits agricoles en magasin sont en cours depuis de nombreuses annees. On a recemment utilise avec succes les rayons gamma dans ces etudes. Les insectes font chaque annee de grands ravages dans les figues seches, qui sont l'un des principaux produits d'exportation de la Grece. L'objet des recherches etait le suivant: 1. Determiner les doses de rayonnements necessaires pour detruire certaines especes d'insectes qui, a differents stades de leur developpement, attaquent les figues, ou detruire leurs oeufs et les empecher ainsi de se reproduire; 2. Determiner les modifications physiques et chimiques que les rayonnements produisent dans la texture de la figue seche. Les travaux ont porte sur les especes suivantes: Plodia interpunctella, Ephestia cautella, Carpophilus hemipterous, Oryzaephilus surinamensis et Lasioderma serricorne. Le memoire etudie les dises optimum d'irradiation, qui ne provoquent aucun dommage visible dans la texture de la figue. (author) [Spanish] Des hace muchos anos se estan

  3. Stabilization of spectra provided by a gamma-ray spectrometer. Application to the construction of a stabilizer; Stabilisation des spectres fournis par un spectrometre a rayons gamma. Application a la realisation d'un stabilisateur

    Energy Technology Data Exchange (ETDEWEB)

    Detourne, G [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-06-15

    This research is concerned with the stabilization of spectra provided by a gamma-ray spectrometer. It is required to hold the calibration straight line of the spectrometer in a position which is fixed initially to better than 5x10{sup -5} channel. A prototype numerical stabilizer has been constructed : the SPECTROSTAB; it is made up of two independent control loops; one of these makes the spectrometer gain depend on the derivatives of a reference peak at high energies; the other makes the origin of the energy scale depend on the derivatives of a second reference peak at low energies A theoretical study of the behaviour of a control loop shows that a direct action stabilizer gives the most accurate stabilization; the loss in resolving power on the theoretical peaks of the spectra attains about 1 % with a scintillation detector, and 10 % with a semi-conductor detector. Various tests show that the expected results are obtained and that the displacement of the spectral peaks produced by the derivatives are hidden by errors in the calculation of the peak abscissae. (author) [French] Cette etude a pour objet la stabilisation des spectres fournis par un spectrometre a rayons gamma. On veut maintenir la droite d'etalonnage du spectrometre dans une position fixee initialement a mieux de 6.10{sup -5} canal pres. On realise un prototype de stabilisateur numerique, le SPECTROSTAB; il comprend deux boucles d'asservissement independantes; l'une d'elles asservit le gain du spectrometre aux derives d'un pic de reference aux hautes energies; l'autre asservit l'origine de l'echelle des energies aux derives d'un second pic de reference aux basses energies. Une etude theorique du comportement d'une boucle d'asservissement montre qu'un stabilisateur a action directe permet la stabilisation la plus precise; la perte en resolution sur les pics theoriques des spectres atteint environ 1 % avec un detecteur a scintillateur et 10 % avec un detecteur a semi-conducteur. Divers essais montrent

  4. Some Uses of Radioisotopes and Radiations in Entomology; Quelques emplois des radioelements et des rayonnements en entomologie; Nekotorye vidy primeneniya radioehlementov i oblucheniya v ehntomologii; Algunas aplicaciones de los radioelementos y de las radiaciones en entomologia

    Energy Technology Data Exchange (ETDEWEB)

    Courtois, G. [Centre d' Etudes Nucleaires de Saclay (France); Lecomte, J. [Institut National de la Recherche Agronomique, Station de Recherches sur l' Abeille et les Insectes Sociaux, Bures-Sur-Yvette (France)

    1963-09-15

    The paper reviews the applications of radioisotopes in entomology that have been developed at our two centres during the last few years. Early work (Au{sup 198}-labelling) related to the bee and more particularly to the radius of dispersion of worker bees from a colony. After investigations on the individual dose received in tagging of this kind, the radioresistance of the bee was determined, the lethal dose being estimated at about 90 kr. Au{sup 198} was also used to study exchange of food within a bee-hive. On the other hand, P{sup 32} was used for studies of exchange of food, in small hives, between individuals of different functions (males, workers and queens) or different colonies. Similar trophallaxic studies have recently been performed on wasps. Au198 was likewise the basic radioisotope used in work on ant's nests. The most interesting finding from one of the early studies was that exchange of food takes place between nests more than 50 m apart and belonging to different species (Formica rufa and Formica polyctena). A later study, in which an ant run and not the nest itself was labelled, revealed a division of responsibility within the nests the tagged ants were found invariably to explore the same run and to have little contact with other individuals of the same colony. In the same experiment abnormal radioactivity was noted in the ants before labelling, due in particular to (Sr+Nb){sup 95} . This discovery would seem to point to accumulation of radioactive fall-out in ant's nests. At a period of low fall-out, natural radioactivity attributed to K{sup 40} was observed and was used for purposes of potassium determination in ants and bees. An attempt was made to label acridians with Ir{sup 192} and the findings are described in the paper. Lastly, an autoradiographic study has been made of the distribution of certain radioisotopes (P{sup 32} and S{sup 35}) in the body of the bee. (author) [French] Le memoire passe en revue les applications des radioelements

  5. Search for charged Higgs bosons at LEP2 with Delphi detector; Recherche des bosons de higgs charges a LEP2 avec le detecteur DELPHI

    Energy Technology Data Exchange (ETDEWEB)

    Silvestre, R

    1997-09-01

    Charged Higgs bosons are particles that are predicted by most theoretical models based on the minimal standard model, they are responsible for the breaking of the symmetry implied by the gauge group SU(2){sub L}*U(1){sub Y}. This work is devoted to the search after this particle in the experimental data collected by the DELPHI experiment. Different analysis strategies have been defined to study the 3 possible final states: H{sup +}H{sup -} {yields} {tau}{sup +}{nu}{sub {tau}}{tau}{sup -}{nu}-bar{sub {tau}}, H{sup +}H{sup -} {yields} cs{tau}{nu}{sub {tau}} and H{sup +}H{sup -} {yields} cs-bar c-bar s. Different hypothesis have been made about the value of the branching ratio of the hadronic decay of Higgs boson. After having analysed the experimental data collected when electron-positron collision energy was 161.3 GeV (in the mass center frame) the author concludes that: m{sub H} > 48.7 GeV/c{sup 2} if Br(H{sup +} {yields} hadrons) < 0.6 (90% CL). A similar analysis performed on all the experimental data leads to: m{sub H} > 52 GeV/c{sup 2} if Br(H{sup +} {yields} hadrons) < 0.7 (95% CL). At the end of 1995 the LEP collider entered a new operating phase (LEP2) which would eventually enable the collision energy to reach 192 GeV in the mass center frame. An analysis of a simulation representing LEP2 operating at 192 GeV has been made. From this analysis the author concludes first that it will be possible to discover a Higgs boson in LEP2 only if its mass is less than 60 GeV/c{sup 2}, secondly that if no Higgs boson is detected at the end of LEP2 phase, it will mean that its mass is greater than 70 GeV/c{sup 2}. (A.C.)

  6. Study of the Pierre Auger Observatory ground detectors: tests, simulation and calibration; Etude des detecteurs de surface de l'observatoire Pierre Auger: tests, simulation et etalonnage

    Energy Technology Data Exchange (ETDEWEB)

    Creusot, A

    2004-10-01

    The Pierre Auger Observatory is intended to the ultra high energy cosmic rays study. This study is realized through the particles showers coming from the interaction between the cosmic rays and the atmosphere. The ground detection of these showers requires a comprehensive understanding of the detectors. Several test tanks have been elaborated for this purpose, especially the Orsay one. The first chapter is dedicated to the presentation of the cosmic rays and of the Pierre Auger Observatory. The second one describes the detectors used for the Observatory surface array. The Orsay test tank is then presented and detailed. We study the results we have got with the Orsay test tank in the fourth chapter and compare these results with those of the Observatory detectors in the fifth chapter. The sixth chapter is dedicated to the validation of the results set through the simulation (GEANT4 software). Finally, the first detected particles showers are presented in the seventh chapter. The data acquisition has begun this year. The construction will be finished by end of 2005. From this moment, The Pierre Auger Observatory will allow us to contribute to solving the cosmic rays puzzle. (author)

  7. Production and semileptonic decays of heavy quarks at LEP with the ALEPH detector; Production et desintegrations semileptoniques des quarks lourds au LEP avec le detecteur ALEPH

    Energy Technology Data Exchange (ETDEWEB)

    Monteil, St.

    1996-05-15

    The four LEP experiments have collected nearly 16 million Z. These very high statistics allow to perform a large field of precision tests of the standard model of electroweak interactions with a very high accuracy. One of the most promising channel in order to observe a deviation with respect to the SM predictions is the study of the b quark production in the Z boson decay. Two observables are of interest in that respect: the Z partial decay width in b quarks, denoted R{sub b} and the b forward-backward asymmetry. A measurement of R{sub b} using both the long lifetime of b hadrons and the kinematical properties of the leptons coming from the semileptonic decays of b hadrons is presented in the first part of this document. The c partial decay width, denoted R{sub c}, is simultaneously measured. 1.3 million of Z have been analyzed and the following results have been obtained: R{sub b} = 21.82 {+-}0.25{+-}0.24%; R{sub c} = 16.02{+-}0.56{+-}1.41%. The former error is statistical and the latter systematics. These two results are in good agreement with the SM predictions. The semileptonic branching ratios of the b hadrons, denoted Br(b {yields} l{sup -}) for the primary decay and Br(b {yields} c {yields} l{sup +}), for the cascade decay, on one hand, and the B{sup 0} {r_reversible} B-bar{sup 0} mixing parameter, denoted X, on another hand are needed in the b asymmetry measurement with the leptons. The second part of this document is devoted to their measurement. This is done by using both lifetime of b hadrons and kinematical characteristics of the leptons coming from semileptonic decays of b hadrons. The following results have been obtained: Br(b {yields} l) 11.03 {+-} 0.07 {+-} 0.21 + 0.24%- 0.17%; Br(b {yields} C {yields} l) 7.84 {+-} 0.12 {+-} 0.30 + 0.34% - 0.43%; X 12.62 {+-} 0.56 {+-} 0.24 + 0.42% - 0.41%. Those results are found in a good agreement with the heavy quark theory predictions. (Abstract Truncated)

  8. Gas detectors for thermal neutron at high counting rates; Etude des detecteurs a gaz pour neutrons thermiques fonctionnant en collection de courant

    Energy Technology Data Exchange (ETDEWEB)

    Mai, V Q [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1965-09-01

    After reminding of the current pulse formation theory in a cylindrical shape counter with and without gas multiplication, one gives the schemes of pulse amplifier and level discriminator which have allowed to verify the above calculations and to make clear the part at high counting rates of the space charge in proportional counters. The theory of that phenomenon is given in chapter V I at last, one gives the results obtained in a nuclear reactor with a counting-channel built with the above electronics circuits. (author) [French] Apres avoir rappele la theorie de la formation de l'impulsion de courant dans un compteur a geometrie cylindrique, fonctionnant sans et avec multiplication de charge, on etudie l'amplificateur et le discriminateur qui ont permis de verifier experimentalement les calculs precedents et de mettre en evidence l'action de la charge d'espace dans les compteurs proportionnels fonctionnant a tres fort taux de comptage. Une theorie de ce phenomene est donnee au chapitre VI; on indique enfin les resultats obtenus dans un reacteur avec une chaine de comptage utilisant les circuits electroniques precedents. (auteur)

  9. Study of Au+Au relativistic collisions with the Fopi-Phase I detector; Etude des collisions relativistes Au+Au avec le detecteur Fopi-Phase I

    Energy Technology Data Exchange (ETDEWEB)

    Dupieux, P

    1995-01-01

    Au+Au relativistic collisions, in a 100-1000 MeV energy domain per nucleon, are described. Experiments have been carried out with the SIS accelerator at GSI/Darmstadt. Data are analysed with the FOPI-phase I detector. These data are compared with IQMD model (Isospin Quantum Molecular Dynamics) Predictions. (S.G). 80 refs., 77 figs., 5 tabs.

  10. Study of heavy ions collision at SIS energies with the detector FOPI; Etude des collisions d'ions lourds aux energies de SIS avec le detecteur FOPI

    Energy Technology Data Exchange (ETDEWEB)

    Bastid, N

    1999-09-23

    The present work has been carried out in the framework of experiments performed with the FOPI detector at the SIS/ESR accelerator facility of GSI-Darmstadt. It is devoted to the study of central and semi-central heavy ion collisions at beam energies ranging from 100 MeV to 2 GeV per nucleon. We present first generalities on relativistic heavy ion collisions then the FOPI detector with a special attention to the FOPI Inner Wall constructed by the Clermont-Ferrand group. The main results of the FOPI collaboration obtained with light and intermediate mass fragments and kaons are presented. A systematic study of the different forms of collection motion of nuclear matter, radial flow in very central reactions, sideward flow and squeeze-out in semi-central collisions, is performed. Further exciting possibilities concerning production and propagation of strangeness at SIS energies will be offered soon with the upgrade of the FOPI detector. The FOPI data have introduced constraints on parameters of theoretical models. Important progress concerning the knowledge of the properties of nuclear matter, the dynamics of the collisions and in-medium effects have been achieved. (author)

  11. Study of the Pierre Auger Observatory ground detectors: tests, simulation and calibration; Etude des detecteurs de surface de l'observatoire Pierre Auger: tests, simulation et etalonnage

    Energy Technology Data Exchange (ETDEWEB)

    Creusot, A

    2004-10-01

    The Pierre Auger Observatory is intended to the ultra high energy cosmic rays study. This study is realized through the particles showers coming from the interaction between the cosmic rays and the atmosphere. The ground detection of these showers requires a comprehensive understanding of the detectors. Several test tanks have been elaborated for this purpose, especially the Orsay one. The first chapter is dedicated to the presentation of the cosmic rays and of the Pierre Auger Observatory. The second one describes the detectors used for the Observatory surface array. The Orsay test tank is then presented and detailed. We study the results we have got with the Orsay test tank in the fourth chapter and compare these results with those of the Observatory detectors in the fifth chapter. The sixth chapter is dedicated to the validation of the results set through the simulation (GEANT4 software). Finally, the first detected particles showers are presented in the seventh chapter. The data acquisition has begun this year. The construction will be finished by end of 2005. From this moment, The Pierre Auger Observatory will allow us to contribute to solving the cosmic rays puzzle. (author)

  12. Current signal of silicon detectors facing charged particles and heavy ions; Reponse en courant des detecteurs silicium aux particules chargees et aux ions lourds

    Energy Technology Data Exchange (ETDEWEB)

    Hamrita, H

    2005-07-01

    This work consisted in collecting and studying for the first time the shapes of current signals obtained from charged particles or heavy ions produced by silicon detectors. The document is divided into two main parts. The first consisted in reducing the experimental data obtained with charged particles as well as with heavy ions. These experiments were performed at the Orsay Tandem and at GANIL using LISE. These two experiments enabled us to create a data base formed of current signals with various shapes and various times of collection. The second part consisted in carrying out a simulation of the current signals obtained from the various ions. To obtain this simulation we propose a new model describing the formation of the signal. We used the data base of the signals obtained in experiments in order to constrain the three parameters of our model. In this model, the charge carriers created are regarded as dipoles and their density is related to the dielectric polarization in the silicon detector. This phenomenon induces an increase in permittivity throughout the range of the incident ion and consequently the electric field between the electrodes of the detector is decreased inside the trace. We coupled with this phenomenon a dissociation and extraction mode of the charge carriers so that they can be moved in the electric field. (author)

  13. High spatial and time resolutions with gas ionization detectors; Hautes resolutions en position et temps avec des detecteurs gazeux a ionisation

    Energy Technology Data Exchange (ETDEWEB)

    Pouthas, J

    2001-09-01

    This document presents the principles and the characteristics of the gaseous ionisation detectors used in position and timing measurements. The first two parts recall the main notions (electron and ion motions, gaseous amplification, signal formation) and their applications to the proportional counter and the wire chamber. The explanation of the signal formation makes use of the Ramo theorem. The third part is devoted to the different types of wire chambers: drift or cathode strip chambers, TPC (time projection chamber). Some aspects on construction and ageing are also presented. Part 4 is on the detectors in which the multiplication is performed by a 'Parallel Plate' system (PPAC, Pestov counter). Special attention is paid to the RPCs (Resistive Plate Chambers) and their timing resolutions. Part 5 concentrates on 'Micro-pattern detectors' which use different kinds of microstructure for gaseous amplification. The new detectors MICROMEGAS, CAT (compteur a trous) and GEM (gas electron multiplier) and some of their applications are presented. The last part is a bibliography including some comments on the documents. (author)

  14. The Use of Ionizing Radiation in the Vulcanization of Silicon Rubber; Utilisation des radiations ionisantes pour la vulcanisation du caoutchouc au silicone; Ispol'zovanie ioniziruyushchikh izluchenij dlya vulkanizatsii silikonovogo kauchuka; Empleo de las radiaciones ionizantes en la vulcanizacion del caucho de siliconas

    Energy Technology Data Exchange (ETDEWEB)

    Kuzminsky, A S; Nikitina, T S; Oksentevich, L A [Rubber Research Institute, Moscow, Union of Soviet Socialist Republics (Russian Federation)

    1960-07-15

    Main purpose of the work - a detailed study of the properties of materials obtained by irradiating mixtures of polydimethylsiloxan e rubber and various fillers (special silicic acid, titanium dioxide, flue dust, chimney soot and lamp black). The irradiation was done with a powerful X-ray unit and a Co{sup 60} gamma-ray source of 20,000 gr. radium equivalent. The relative speed of formation of the space lattice of the vulcanized material was evaluated (by the size of the equilibrium constant and the maximum degree of swelling in benzene). Changes in tensile strength and specific elongation during the irradiation process were studied. The optimum vulcanization regime was chosen and the basic physico-mechanical characteristics of the vulcanized materials were defined. Changes in the properties of the irradiated vulcanized material during hot aging at temperatures of 150{sup o}, 200{sup o} and 250{sup o} were studied. Irradiation in vulcanization removes the necessity for carrying out the process at high temperatures and for keeping the product under controlled temperature conditions for long periods after vulcanization. This new method of vulcanizing allows the use of carbon black as a filler. The use of ionizing radiation makes it possible to simplify the technique of vulcanizing silicon rubber and to improve the properties of the vulcanized material. (author) [French] L'etude porte avant tout sur les proprietes des matieres qu'on obtient apres avoir expose a des radiations du caoutchouc au polydimethyl-siloxane melange a des produits d'addition differents (acide silicique special, bioxyde de titane, noir de fumee en poudre impalpable obtenu au four et a la lampe). L'exposition aux radiations s'effectuait dans une installation puissante de rayons X et avec une source de rayonnement gamma en {sup 60}Co avec une activite de 20 000 g. eq. ra. Les auteurs ont evalue la vitesse relative de formation du reseau spatial des vulcanisants (selon la grandeur du module d

  15. Radiative transfer modelling in combusting systems using discrete ordinates method on three-dimensional unstructured grids; Modelisation des transferts radiatifs en combustion par methode aux ordonnees discretes sur des maillages non structures tridimensionnels

    Energy Technology Data Exchange (ETDEWEB)

    Joseph, D.

    2004-04-01

    The prediction of pollutant species such as soots and NO{sub x} emissions and lifetime of the walls in a combustion chamber is strongly dependant on heat transfer by radiation at high temperatures. This work deals with the development of a code based on the Discrete Ordinates Method (DOM) aiming at providing radiative source terms and wall fluxes with a good compromise between cpu time and accuracy. Radiative heat transfers are calculated using the unstructured grids defined by the Computational Fluid Dynamics (CFD) codes. The spectral properties of the combustion gases are taken into account by a statistical narrow bands correlated-k model (SNB-ck). Various types of angular quadrature are tested and three different spatial differencing schemes were integrated and compared. The validation tests show the limit at strong optical thicknesses of the finite volume approximation used the Discrete Ordinates Method. The first calculations performed on LES solutions are presented, it provides instantaneous radiative source terms and wall heat fluxes. Those results represent a first step towards radiation/combustion coupling. (author)

  16. Modelisation des effets physico-techniques pour la conception des ...

    African Journals Online (AJOL)

    automatisation dans les installations industrielles a besoin d'une régulation automatique des commandes des processus technologiques pour lesquelles certaines contraintes sont à relever compte tenu des exigences des innovations scientifiques de ...

  17. Intensity modulated radiation therapy: Analysis of patient specific quality control results, experience of Rene-Gauducheau Centre; Radiotherapie conformationnelle avec modulation d'intensite: analyse des resultats des controles precliniques, experience du centre Rene-Gauducheau

    Energy Technology Data Exchange (ETDEWEB)

    Chiavassa, S.; Brunet, G.; Gaudaire, S.; Munos-Llagostera, C.; Delpon, G.; Lisbona, A. [Service de physique medicale, centre Rene-Gauducheau, CLCC Nantes Atlantique, site hospitalier Nord, boulevard Jacques-Monod, 44805 Nantes Saint-Herblain cedex (France)

    2011-07-15

    Purpose. - Systematic verifications of patient's specific intensity-modulated radiation treatments are usually performed with absolute and relative measurements. The results constitute a database which allows the identification of potential systematic errors. Material and methods. - We analyzed 1270 beams distributed in 232 treatment plans. Step-and-shoot intensity-modulated radiation treatments were performed with a Clinac (6 and 23 MV) and sliding window intensity-modulated radiation treatments with a Novalis (6 MV). Results. - The distributions obtained do not show systematic error and all the control meet specified tolerances. Conclusion. - These results allow us to reduce controls specific patients for treatments performed under identical conditions (location, optimization and segmentation parameters of treatment planning system, etc.). (authors)

  18. Basis and development of legislative radiation protection regulations in medicine; Basis und Entwicklung der gesetzlichen Regelungen des Strahlenschutzes in der Medizin

    Energy Technology Data Exchange (ETDEWEB)

    Streffer, Christian

    2017-07-01

    In the frame of the radiation protection law (version 2017) the medical exposure has a special exceptional position because even in case of profound radiation protection measures the annual dose limit of 1 mSv is very often surmounted. The acting radiologist using ionizing radiation or radioactive materials within diagnostic or therapeutic nuclear medicine has a high responsibility with respect to benefit or hazard of the planned exposure. Especially in the cases of children, pregnant women or persons with high radiation sensitivity the consideration of radiation hazards is of eminent importance.

  19. Implication of MMP and TIMP in the matrice remodeling: early and delayed radiation effects of the digestive tractus; Implication des MMP et des TIMP dans le remodelage matriciel: effets aigus et tardifs de l'irradiation du tractus digestif

    Energy Technology Data Exchange (ETDEWEB)

    Strup-Perrot, C

    2004-12-15

    irradiation induces a marked acute remodeling of the gut wall and may lead to late fibrosis. Combining morphological, biochemical and molecular approach, we studied the expression of MMP and TIMP in the ileum and colon of rats one to seven days after irradiation and in ileum of patients with radiation enteritis. In both studies expression and activity of MMP and TIMP were increased, their balance being in favor of extra-cellular matrix degradation in the acute phase while in favor of matrix accumulation in radiation enteritis. (author)

  20. Implication of MMP and TIMP in the matrice remodeling: early and delayed radiation effects of the digestive tractus; Implication des MMP et des TIMP dans le remodelage matriciel: effets aigus et tardifs de l'irradiation du tractus digestif

    Energy Technology Data Exchange (ETDEWEB)

    Strup-Perrot, C

    2004-12-15

    irradiation induces a marked acute remodeling of the gut wall and may lead to late fibrosis. Combining morphological, biochemical and molecular approach, we studied the expression of MMP and TIMP in the ileum and colon of rats one to seven days after irradiation and in ileum of patients with radiation enteritis. In both studies expression and activity of MMP and TIMP were increased, their balance being in favor of extra-cellular matrix degradation in the acute phase while in favor of matrix accumulation in radiation enteritis. (author)

  1. An Assessment of those Metabolites Considered to be of Value in the Diagnosis of Exposure to Radiation; Evaluation des Metabolites Consideres Comme Utiles dans le Diagnostic des Expositions aux Rayonnements; 041e 0426 0414 ; Evaluacion de los Metabolitos Considerados Utiles para Diagnosticar la Exposicion a las Radiaciones

    Energy Technology Data Exchange (ETDEWEB)

    Smith, H.; Bates, T. H. [United Kingdom Atomic Energy Authority, Chapelcross, Annan, Scotland (United Kingdom)

    1965-06-15

    Certain metabolites excreted in urine have been examined in cases of human beings exposed to X- and y-irradiation for therapeutic reasons. These patients were receiving doses of up to 5000 r over a period of three to five weeks. Urinary excretion of creatinine, creatine, total {alpha}-amino-nitrogen, {beta}-amino-isobutyric acid, pyrrole-2-carboxylic acid, 5-hydroxyindoleacetic acid and indoxyl-sulphate were followed quantitatively during the whole course of treatment. None of the patients were exposed to total-body irradiation but it is apparent that changes in metabolic function as a result of radiation-induced damage can be reflected in urinary excretion. The biochemical rationale and interpretation of these excretion patterns is discussed in relation to that part of the body irradiated, but it is concluded at this stage of the investigation that quantitative assessment of biological damage is not possible. However, such tests can be useful as a guide to the clinician on the form of therapy. Preliminary tests on changes in certain plasma metabolites in rats exposed to single sub-lethal doses of X-irradiation are worthy of extrapolation to human studies. Plasma concentrations of 5-hydroxytryptamine, uric acid, SGOT, SGPT, globulin fractions of protein, creatine phosphokinase, leucine aminopeptidase, lysyl aminopeptidase, kallikrein, kallidin, zinc and manganese have been measured. Qualitative yet significant changes were observed in plasma levels of uric acid, leucine aminopeptidase, lysyl aminopeptidase and manganese after irradiation. The significance of this data is discussed. Emphasis in these studies has been placed upon methods which are simple and quick to perform. (author) [French] On a examine certains metabolites excretes dans l'urine par des etres humains exposes, a des fins therapeutiques, aux rayons X et gamma. Ces sujets recevaient des doses allant jusqu'a 5000 r pendant une periode de trois a cinq semaines. Pendant toute la duree du traitement, on

  2. Characterization of ionizing radiation effects in MOS structures by study of bipolar operation; Caracterisation des effets induits par irradiations ionisantes dans des structures MOS a partir de leur fonctionnement en regime bipolaire

    Energy Technology Data Exchange (ETDEWEB)

    Bakhtiar, H. [Univ. Teknologi Malaysia, Dept. of Physics, Johor (Malaysia); Picard, C.; Brisset, C. [CEA Saclay, Lab. d' Electronique et de Technologie de l' Informatique, LETI, 91 - Gif-sur-Yvette (France); Bakhtiar, H.; Hoffmann, A.; Charles, J.P. [Metz Univ., LICM-CLOES-Supelec, 57 (France)

    1999-07-01

    This work presents an original method to characterize radiation effects of micronic transistors. The characterization includes a study of the transistor substrate-drain junction and current gain variation of the bipolar transistor (drain-substrate-source as emitter-base-collector) for different gate voltages. (author000.

  3. variabilite des productions et des revenus des exploitations

    African Journals Online (AJOL)

    3Centre de coopération internationale en recherche agronomique pour le développement (CIRAD), UMR Innovation,. Montpellier, France. Doubangolo COULIBALY, Email kone_b@yahoo.fr. RESUME. La durabilité des systèmes de production à base de coton dans un contexte de variabilité des prix aux producteurs et de ...

  4. Effects of Ionizing Radiation on Insects and Other Arthropods; Effet des rayonnements ionisants sur les insectes et autres arthropodes; Vozdejstvie ioniziruntsej radiatsii na nasekomykh i drugikh chlenistonogikh; Efectos de las radiaciones ionizantes sobre los insectos y otros artropodos

    Energy Technology Data Exchange (ETDEWEB)

    Stone, William E. [United States Department of Agriculture Laboratories, Mexico City, D.F (Mexico)

    1963-09-15

    -Star tick, Amblyomma americanum L., and ionizing radiation as a possible quarantine treatment for fruits and vegetables infested with fruit flies and mangoes infested with the mango weevil, Sternochetus mangiferae Fabricius, are also discussed. (author) [French] Des recherches sur la possibilite d'appliquer la methode de sterilization par les rayonnements pour l'eradication de populations d'insectes sont actuellement en cours pour un certain nombre d'insectes nuisibles a l'homme, aux animaux et a diverses cultures. Il ressort de ces recherches preliminaires que les rayonnements ionisants provoquent la sterilite, mais que les doses necessaires varient considerablement. Ces recherches donnent aussi a penser que les dommages radioinduits sont tels qu'il ne serait pas opportun d'appliquer cette methode a toutes les especes d'insectes. Une difficulte a laquelle on se heurte frequemment est l'absence de methodes pratiques d'elevage en masse. D'autre part, certaines populations d'insectes sont tellement nombreuses qu'il peut etre impossible de recourir a cette methode sans avoir au prealable applique dans la region infestee d'autres methodes de lutte de maniere a pouvoir atteindre les populations naturelles. Malgre ces difficultes, si les conditions sont favorables, il existe peu d'autres methodes qui puissent donner d'aussi bons resultats. On peut aussi envisager de recourir a la methode de sterilisation par les rayonnements pour retarder la pullulation des insectes jusqu'a la moisson des recoltes. Le memoire rend compte de l'influence des rayons gamma sur la capacite de reproduction, l'agressivite sexuelle, la vigueur et la longevite de divers insectes: mouche orientale des fruits Dacus dorsalis Hendel, mouche du melon Dacus cucurbitae Coq., mouche mediterraneenne des fruits Ceratitis capitata Wied, mouche mexicaine des fruits Anastrepha ludens Loew et Anopheles quadrimaculatus Say; il donne aussi les resultats d'experiences reelles de lacher de males steriles pour l

  5. Effects of Monoenergetic Neutron Radiation on Human Cells in Tissue Culture; Effets des Neutrons Monoenergetiques sur des Cellules de Tissus Humains en Culture; Dejstvie oblucheniya monoehnergeticheskimi nejtronami na kletki kul'tury tkanej cheloveka; Efectos de la Radiacion Neutronica Monoenergetica sobre las Celulas Humanas en Cultivos de Tejidos

    Energy Technology Data Exchange (ETDEWEB)

    Broerse, J. J.; Barendsen, G. W. [Radiobiological Institute of the Organization for Health Research TNO, Rijswijk (Z.H.) (Netherlands)

    1964-03-15

    Dose effect relations concerning inhibition of clone formation by kidney cells of human origin in culture after irradiation with monoenergetic neutrons of about 3-MeV and about 15-MeV energy, are reported. For 3-MeV neutrons the dose rate was equal to 0.2 rad/min, while for 15-MeV neutrons dose rates of 2.7 rad/min and 12 rad/min were obtained. The cells were irradiated in culture dishes with a thin Melinex bottom and in small flexible nylon and silicon rubber tubes. Neutron fluxes were determined by measuring the activation of sulphur pellets mounted respectively between the dishes and the tubes. Calculation of the dose on the basis of the neutron flux presented a number of problems which are discussed. Because no radiation equilibrium exists around the cells, the resulting inaccuracies in the dose determinations are investigated. Dose-survival curves for both types of neutrons are presented. For 3-MeV neutrons an RBE was found ranging from 6.5 at low doses to about 3.1 at high doses, while for 15-MeV neutrons the RBE varied from 1.9 to 1.6. By comparison of these RBE-values with the RBE-LET relation obtained in earlier experiments with deuterons and {alpha}-particles, it is possible to derive an effective LET for the neutrons used. In order to elucidate certain problems related to the death of experimental animals after X- or neutron- irradiation, a technique has been developed whereby the cells, contained in small tubes, are used to measure the effective dose (i.e . dose corrected for the RBE) at sites of interest in phantoms or animals. (author) [French] Les auteurs indiquent les relations dose-effet pour l 'inhibition de la formation de lignees par les cellules renales d' origine humaine apres irradiation par des neutrons monoenergetiques de 3 MeV et de 15 MeV. Pour les neutrons de 3 MeV, le debit de dose etait egal a 0,2 rad/min, alors que pour les neutrons de 15 MeV on a obtenu des debits de dose de 2,7 rad/min et de 12 rad/min. L'irradiation des cellules

  6. Delayed neutron detection in canning burst detection studies (1961); Etude sur la detection des neutrons differes en vue de la detection des ruptures de gaines (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Perlini, G [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    This paper describes a theoretical and experimental study on the detection of neutrons present in the primary cooling circuit of a reactor cooled by heavy or light water, with a view to the installation of a canning burst detection unit. The concentration of background neutrons is first calculated, taking into account the neutrons from nitrogen 17 decay, and the photoneutrons produced by the decay of nitrogen 16 and sodium 24. The emission of delayed fission neutrons, originating at a given crack in the canning, has been estimated. Using the D{sub 2}O circuit of the pile EL-3, three units have been developed by means of which the following three types of detector may be compared: 1) BF{sub 3} proportional counter 2) Boron scintillator 3) Fission chamber Under the present experimental conditions the BF{sub 3} counter gave the best results. The influence on these detectors of the {gamma} flux, which in certain cases reaches 200 R/h, is analysed. Finally a calibration is carried out with an experimental crack of 30 mm{sup 2} of uranium exposed to a flux of 5.8 x 10{sup 13} n.cm{sup -2}.s{sup -1}. The sensitivity obtained with the BF{sub 3} counter during this test is 2 counts/s per mm{sup 2} of exposed uranium. (author) [French] Le present rapport est une etude theorique et experimentale sur la detection des neutrons presents dans le circuit primaire de refroidissement d'un reacteur refrigere par l'eau lourde ou l'eau legere, en vue d'une installation de detection de ruptures de gaines. On fait d'abord un calcul sur la concentration des neutrons de bruit de fond en tenant compte: des neutrons de decroissance de l'azote 17 et des photoneutrons produits par les decroissances de l'azote 16 et du sodium 24. L'emission des neutrons differes de fission, qui ont pour origine une fissure de gaine donnee, a ete evaluee. Utilisant le circuit D{sub 2}O de la pile EL3, trois installations ont ete mises au point permettant de comparer les trois types de detecteurs suivants: 1

  7. The new radiation protection ordinance from the viewpoint of the nuclear medicine technologist; Die neue Strahlenschutzverordnung aus der Sicht der medizinisch-technischen Radiologieassistentin/des medizinisch-technischen Radiologieassistenten

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, S. [Klinik und Poliklinik fuer Nuklearmedizin, Ludwig-Maximilians-Univ. Muenchen (Germany)

    2002-05-01

    The new radiation protection ordinance for the first time acknowledges the role of the nuclear medicine technologists for the technical assistance in the use of radiopharmaceuticals and radiation with human beings in medicine. Therefore changes are required for the technologists in terms of their qualification and continuing education during their professional life and in the daily routine in a nuclear medicine department. The new ordinance clearly defines which group of people is allowed to work as nuclear medicine technologists and also which special knowledge in radiation protection is mandatory to make sure that nobody without this certified education is performing the work of a nuclear medicine technologist. The new effective dose limit for people working with radiation will not change the daily work, but new regulations for pregnant women or breastfeeding mothers working in nuclear medicine will bring dramatic changes. (orig.) [German] Die neue Strahlenschutzverordnung beruecksichtigt zum ersten Mal ausdruecklich die Rolle des medizinisch-technischen Personals bei der 'technischen Mitwirkung bei der Anwendung radioaktiver Stoffe oder ionisierender Strahlung am Menschen in der Heilkunde oder der Zahnheilkunde'. Dadurch ergeben sich fuer die MTRA neue Anforderungen in Bezug auf Ausbildungsvoraussetzungen, berufliche Fortbildung und auch auf die Ablaeufe in der taeglichen Routine. Der Personenkreis, der zur technischen Mitwirkung berechtigt ist, wurde genau definiert, ebenso wie dessen Fachkunde, mit der nun sichergestellt werden soll, dass keine Personen ohne Kenntnisse im Strahlenschutz die Taetigkeiten der MTRA ausfuehren. Die neu festgelegte Obergrenze der effektiven Dosis fuer beruflich strahlenexponiertes Personal wird fuer das technische Personal keine merkbaren Auswirkungen mit sich bringen, dafuer aber die Neuerungen bezueglich der Beschaeftigung von Schwangeren und stillenden Frauen. (orig.)

  8. A study of the fluorescence of the rare gases excited by nuclear particles. Use of the principle for the detection of nuclear radiation by scintillation; Etude de la fluorescence des gaz rares excites par des particules nucleaires. Utilisation pour la detection des rayonnements nucleaires par scintillation

    Energy Technology Data Exchange (ETDEWEB)

    Koch, L [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1959-12-15

    In the first part is studied the properties of atoms excited by the passage of {alpha} particles through the various rare gases at atmospheric pressure. A spectral analysis of the emitted light showed that certain impurities play an important part in producing the fluorescence, and it has led to the conclusion that the light emission contains at least two components - one very short - lived due to the direct deexcitation of the rare gas, the other relatively slower due to the energy transfers to the impurity. The measurement of the life-time of the excited states has confirmed this foregoing hypothesis, the rapid part of the impulse is extremely short: less than 2,25.10{sup -9} s in the case of xenon; the slower part has a life-time depending directly on the nitrogen concentration, nitrogen being the impurity giving the largest effect in all cases. The study of rare gases under the influence of an electric field has made it possible to show that the amount of light produced by an {alpha} particle can be multiplied (by 60, for example, in a field of 600 V:cm) so that the luminescent efficiency is greater than in the case of INaTI. In the second part the characteristics of the rare gases acting as scintillators is examined, the most important property being the absence of fluorescence saturation when the intensity of the excitation incident on the gas is very large. This, together with the very short time of scintillation has made it possible to study a certain number of nuclear physical applications (heavy particle energy-measurements, kinetic studies on nuclear reactors, neutron spectroscopy). (author) [French] On etudie dans la premiere partie les proprietes des atomes excites par le passage de particules {alpha} dans les differents gaz rares a la pression atmospherique. L'etude spectrale de la lumiere emise a montre que certaines impuretes jouent un role considerable dans la fluorescence et on a ete amene a penser que l'emission de lumiere comporte au moins deux

  9. Radiations

    International Nuclear Information System (INIS)

    Pujol Mora, J.

    1999-01-01

    The exposition to ionizing radiations is a constant fact in the life of the human being and its utilization as diagnostic and therapeutic method is generalized. However, it is notorious how as years go on, the fear to the ionizing radiation seems to persist too, and this fact is not limited to the common individual, but to the technical personnel and professional personnel that labors with them same. (S. Grainger) [es

  10. Radiation

    International Nuclear Information System (INIS)

    Davidson, J.H.

    1986-01-01

    The basic facts about radiation are explained, along with some simple and natural ways of combating its ill-effects, based on ancient healing wisdom as well as the latest biochemical and technological research. Details are also given of the diet that saved thousands of lives in Nagasaki after the Atomic bomb attack. Special comment is made on the use of radiation for food processing. (U.K.)

  11. Status of Research and Developmental Studies on Radiation Pasteurization of Fish and Shellfish in the United States; Etat des Etudes et des Realisations en Matiere de Radiopasteurisation des Poissons, Crustaces et Mollusques aux Etats-Unis; Sostoyanie nauchno-issledovatel'skikh rabot po radiatsionnoj pasterizatsii ryby i krabov v soedinennykh shtatakh; Estado de las Investigaciones y Estudios Experimentales Sobre la Radiopasteurizacion de Pescados y Mariscos en los Estados Unidos

    Energy Technology Data Exchange (ETDEWEB)

    Slavin, J. W.; Ronsivalli, L. J.; Connors, T. J. [United States Bureau of Commercial Fisheries Technological Laboratory, Gloucester, MA (United States)

    1966-11-15

    This paper reviews the status of research on radiation- pasteurization of fish and shell fish in the United States and describes plans for commercialization of the process. The authors discuss: (a) laboratory studies at universities and governmental research institutions on quality and microbiological aspects of irradiated sea food; (b) developmental investigations on irradiating fish ashore and at sea; and (c) United States clearance of radiation pasteurized sea food and use of the process in the fishing industry. Quality studies indicate that irradiation with cobalt-60 at levels of 150 000 at 450 000 rad can at least double the refrigerated shelf life of 16 species of fish and shell fish, which include the major species marketed as fresh or frozen in the United States. Storage temperature, quality of raw material, and dose level significantly affect product quality and shelf life; packaging is of less significance. Synergistic systems, using bactericidal salts or heat, in conjunction with radiation, effectively destroy bacteria and offer promise in reducing radiation levels and extending product shelf life over that when radiation is used alone. Irradiation at very low levels significantly changes the microbial flora of fish fillets, but interestingly enough this change is no greater than that which occurs when storing the product in an anaerobic environment. In discussing microbiological changes in irradiated and non- irradiated fish, the authors point out that treated fish fillets are as safe and wholesome as the non-treated fish. Work on safety aspects of irradiated fish fillets is discussed in detail. Developmental studies received emphasis with construction and operation of a 250 000 Ci cobalt-60 fish-processing facility at Gloucester, Mass. Tests on packaging and shipping irradiated products under simulated commercial conditions show that pasteurized fish can be handled in the same manner as fresh fish, with a resultant doubling of shelf life for the former

  12. Normal tissue tolerance to external beam radiation therapy: Rectum; Dose de tolerance a l'irradiation des tissus sains: le rectum

    Energy Technology Data Exchange (ETDEWEB)

    Blanchard, P. [Departement de radiotherapie, institut Gustave-Roussy, 94 - Villejuif (France); Chapet, O. [Service d' oncologie-radiotherapie, centre hospitalier Lyon-Sud, 69 - Pierre-Benite (France)

    2010-07-15

    Radiation proctitis is among the most frequent radiation-induced toxicities. This is related to the high frequency of pelvic tumours and the key role of radiotherapy in the treatment of these tumours. Late rectal toxicity usually occurs within the first two years after the completion of a radiotherapy course. Rectal bleeding and a rectal syndrome are the main symptoms, and can be associated to fistulas or rectal ulcers. Clinical factors, such as diabetes mellitus, a severe acute radiation toxicity, small rectal volume or radiation hypersensitivity, are associated with late rectal toxicity. Dosimetric factors derived from the analysis of dose-volume histograms can also predict the occurrence of radiation proctitis, and help to adapt the prescribed dose and the ballistic of irradiation. (authors)

  13. Rational utilisation of a spectrometer detector for leaks; Utilisation rationnelle d'un spectrometre detecteur de fuites

    Energy Technology Data Exchange (ETDEWEB)

    Geller, R [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires

    1954-07-01

    In this following article, we expose the general problem of the leakage in a vacuum installation. We consider the principles of the detection in general and study especially the conditions of detection by an helium spectrometer. We deduce practical conclusions as for the branching of this last and to its application in the most current cases. (author) [French] Dans l'article qui suit, nous exposons le probleme general des fuites dans une installation a vide. Nous y envisageons les principes de la detection en general et etudions particulierement les conditions de detection par spectrometre a helium. Noue tirons des conclusions pratiques quant au branchement de ce dernier et a son application dans les cas les plus courants. (auteur)

  14. Radiation

    International Nuclear Information System (INIS)

    Winther, J.F.; Ulbak, K.; Dreyer, L.; Pukkala, E.; Oesterlind, A.

    1997-01-01

    Exposure to solar and ionizing radiation increases the risk for cancer in humans. Some 5% of solar radiation is within the ultraviolet spectrum and may cause both malignant melanoma and non-melanocytic skin cancer; the latter is regarded as a benign disease and is accordingly not included in our estimation of avoidable cancers. Under the assumption that the rate of occurrence of malignant melanoma of the buttocks of both men and women and of the scalp of women would apply to all parts of the body in people completely unexposed to solar radiation, it was estimated that approximately 95% of all malignant melanomas arising in the Nordic populations around the year 2000 will be due to exposure to natural ultraviolet radiation, equivalent to an annual number of about 4700 cases, with 2100 in men and 2600 in women, or some 4% of all cancers notified. Exposure to ionizing radiation in the Nordic countries occurs at an average effective dose per capita per year of about 3 mSv (Iceland, 1.1 mSv) from natural sources, and about 1 mSv from man-made sources. While the natural sources are primarily radon in indoor air, natural radionuclides in food, cosmic radiation and gamma radiation from soil and building materials, the man-made sources are dominated by the diagnostic and therapeutic use of ionizing radiation. On the basis of measured levels of radon in Nordic dwellings and associated risk estimates for lung cancer derived from well-conducted epidemiological studies, we estimated that about 180 cases of lung cancer (1% of all lung cancer cases) per year could be avoided in the Nordic countries around the year 2000 if indoor exposure to radon were eliminated, and that an additional 720 cases (6%) could be avoided annually if either radon or tobacco smoking were eliminated. Similarly, it was estimated that the exposure of the Nordic populations to natural sources of ionizing radiation other than radon and to medical sources will each give rise to an annual total of 2120

  15. Civili, langue des Baloango

    DEFF Research Database (Denmark)

    Mavoungou, Paul Achille; Ndinga-Koumba-Binza, Hugues Steve

    , Congo, Angola, etc.) issus de la décolonisation. Il présente de façon succincte quelques phénomènes historiques, phonologiques, morphosyntaxiques, homonymiques et analogiques de la langue. Des faits sémantiques des emprunts linguistiques y sont également décrits dans le cadre des changements...

  16. Collection of legislative and regulatory arrangements relative to radiation protection. Part 1: laws and decrees of the Public Health Code and Labour Code concerning the protection of populations, patients and workers against the risks of ionizing radiations; Recueil des dispositions legislatives et reglementaires relatives a la radioprotection. Partie 1: lois et decrets du code de la sante publique et du code du travail concernant la protection de la population, des patients et des travailleurs contre les dangers des rayonnements ionisants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-05-15

    This collection concerns on one hand the protection of the population and on the other hand the protection of the workers against ionizing radiations. As regards the protection of the populations, there is a quality control of waters, a control of the medical devices for the protection of patients. For the protection of the workers it is the employment law which serves as reference. (N.C.)

  17. Radiation-pulse transmission via a long cable without a preamplifier and/or a pulse transformer; Transmission d'impulsions de rayonnement par cable long sans l'adjonction d'un preamplificateur ou d'un transformateur d'impulsions; Peredacha impul'snykh izluchenij no kabelyu na dal'nie rasstoyaniya bez predvaritel'nogo usileniya i/ili bez preobrazovaniya impul'sov; Transmision de impulsos por cables de gran longitud sin preamplificador y/o transformador de impulsos

    Energy Technology Data Exchange (ETDEWEB)

    Miwa, H; Tohyama, T [Kobe Kogyo Corporation, Okubo, Akashi, Hyogo (Japan)

    1962-04-15

    conditions such as high or low temperature, high neutron (gamma) flux, etc. A single coaxial cable enables the simple operation of detectors in remote positions. Scintillation gamma spectroscopy was not affected by a long cable pulse-transmission of over 500 m. (author) [French] Pour l'introduction de transistors dans les instruments d'electronique nucleaire, la faiblesse inherente de l'impedance d'entree exige certaines modifications du circuit d'entree. Les auteurs ont fait une etude comparee de trois circuits d'entree caracterises par leur tension (systeme 1), leur tension-courant (systeme 2) et leur courant (systeme 3). Le systeme 1 est, dans une large mesure, analogue a celui du circuit des tubes a vide classiques. Les auteurs ont mis au point un emetteur-analyseur polarise par contre-reaction; utilise comme circuit a haute impedance d'entree, depassant 10{sup 7} {Omega}, il a donne d'excellents resultats, sans affecter la stabilite du courant continu. Presque tous les detecteurs de rayonnement peuvent etre consideres comme des generateurs de courant. Ainsi, la sortie des detecteurs peut etre connectee a l'amplificateur a faible impedance d'entree. C'est le systeme 3 qui donne une excellente amplitude d'impulsion; toutefois, la limite superieure de frequence de l'amplificateur devrait depasser 10 MHz, compte tenu de la vitesse des impulsions et de la faible valeur de la constante de temps d'integration a l'entree. Le systeme 2 est une combinaison des deux autres. Le courant de sortie des detecteurs est connecte par une resistance de 10{sup 5} {Omega} environ a l'amplificateur a faible impedance d'entree. La resistance donne la valeur convenable a la constante de temps d'integration a l'entree et ramene a 2 MHz environ la limite superieure de frequence exigee par le circuit electronique. En outre, ce dispositif permet de maintenir la proportionnalite entre l'amplitude de l'impulsion et l'energie du rayonnement. Lorsqu'on emploie des detecteurs a gaz, la resistance joue

  18. Study of niobium isotopes having excess neutrons and a short half-life; Etude des isotopes du niobium excedentaires en neutrons et de courte periode

    Energy Technology Data Exchange (ETDEWEB)

    Huebenthal, K [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1968-02-01

    By irradiating Mo with 14 MeV neutrons isomers have been found for {sup 98}Nb (2.8 s half-life) {sup 99}Nb (9 s) and {sup 100}Nb (2.4 s). No isomer of this type seems to exist for {sup 96}Nb. Rapid separation methods are developed for isolating {sup 98}Zr from fission products, and for separating Zr and Nb. The half-life of {sup 98}Zr is measured (31 s) and the formation of {sup 98}Nb (2.8 s) from {sup 98}Zr (31 s) is shown by milking. Rough {beta} and {gamma} measurements of these nuclei are described. The {gamma} spectrum of {sup 98}Nb (51 mn) is studied with a high-resolution Ge/Li - detector. (authors) [French] Des irradiations des isotopes de molybdene avec des neutrons de 14 MeV ont mis en evidence l'existence des isomeres de {sup 98}Nb (periode 2.8 s) {sup 99}Nb (9 s) et {sup 100}Nb (2.4 s). Pour le {sup 96}Nb un isomere de ce type ne semble pas exister. Des methodes rapides de separation sont mises au point pour isoler le zirconium 98 des produits de fission, et pour separer ensuite le niobium du zirconium. La periode du {sup 98}Zr est de 3l s, et on demontre la formation du {sup 98}Nb (2.8 s) a partir du Zr (31 s). Ces corps sont etudies sommairement en spectroscopie {beta} et {gamma}. Le spectre gamma de {sup 98}Nb (periode 51 mn) est etudie avec un detecteur Ge/Li de haute resolution. (auteurs)

  19. Des racines et des ailes

    Directory of Open Access Journals (Sweden)

    Stéphanie Vincent-Geslin

    2012-05-01

    Full Text Available Les mobilités pendulaires semblent être en augmentation en Europe depuis une dizaine d’années. Cette croissance du temps passé à se déplacer amène à remettre en question la conjecture de Zahavi et apparaît relativement inexplicable en regard du paradigme classique de l’acteur rationnel traditionnellement utilisé dans le champ des transports. Si, dans la littérature, les temps de déplacements sont principalement expliqués par le contexte résidentiel, la forme urbaine et le travail, ce cadre explicatif ne dit rien des processus de décision eux-mêmes qui amènent aux pendularités intensives.À partir d’une enquête qualitative menée auprès de pendulaires français, suisses et belges, cette contribution propose d’analyser les arbitrages et les éléments déterminants des processus de la grande pendularité. Les mobilités quotidiennes pendulaires apparaissent comme le résultat de compromis entre activité professionnelle, attachement résidentiel et choix de vie et prennent ainsi la forme de stratégies de conciliation entre vie privée et vie professionnelle. Ces mobilités spatiales permettent alors paradoxalement la préservation des ancrages résidentiels, sociaux et familiaux.Roots and wings. Long-distance commuting patterns, or how to conciliate professional and personal lifeLong-distance commuting patterns appear to be increasing in Europe over the last ten years. These raising mobility patterns lead to reappraise the Zahavi conjecture and appear largely inexplicable by the classical rational actor paradigm traditionally used in transportation research. In literature, commuting is mainly explained by residential contexts, urban forms and job. Nevertheless this theoretical frame says little about the decision-making processes themselves. Based on a qualitative survey conducted in three European countries - France, Belgium and Switzerland – among a population of high commuters, this paper proposes an analysis of

  20. Study of cartridge rupture detection installations; Contribution a l'etude des installations de detection de ruptures de gaine

    Energy Technology Data Exchange (ETDEWEB)

    Graftieaux, J; Douet, P; Roguin, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    Very numerous physical or technological parameters are involved in the preparation of projects for can rupture detection installations. These parameters are connected essentially with the design of the reactor, the detector used, the disposition of the pneumatic circuits, the type of fuel and the safety required. The present report analyses the main problems arising and their mutual compatibilities; it defines a certain number of ideas which had up till now been accepted implicitly in the design. (authors) [French] De tres nombreux parametres physiques ou technologiques interviennent dans l'etablissement du projet d'une installation de detection de ruptures de gaines. Ces parametres decoulent essentiellement de la conception de la pile, du detecteur utilise, de l'organisation des circuits pneumatiques, du type du combustible et de la securite souhaitee. Le present document analyse les principaux problemes qui se posent ainsi que leurs compatibilites reciproques et precise un certain nombre de notions jusqu'alors admises implicitement lors de l'etablissement des projets. (auteurs)

  1. Determination of the cross-sections of some nuclear reactions occurring as a result of cosmic radiation (1963); Determination des sections efficaces de quelques reactions nucleaires intervenant dans les effets ou rayonnement cosmique (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Tamers, M A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1962-06-15

    The high energy reactions studied during this research are reactions liable to occur as a result of cosmic radiation. On the one hand the reaction {sup 16}O(p, 3p){sup 14}C was studied and its cross-section measured between 65 MeV and 2.7 GeV; a value of 2.3 mb {+-} 0.5 was found. These values have mode it possible to forecast measurable quantities of carbon-14 in meteorites and also to measure them. On the other hand the reactions {sup 12}C({sup 16}O...), {sup 12}C({sup 14}N...) and {sup 12}C({sup 12}C...) have been studied and an attempt has been made to explain the mechanism of these reactions. (author) [French] Les reactions a hautes energies qui ont ete etudiees au court de ce travail sont des reactions susceptibles de se produire sous l'effet du rayonnement cosmique. Il s'agit d'une part de la reaction {sup 16}O(p, 3p){sup 14}C dont on a mesure la section efficoce egale a 2,3 mb {+-} 0,5 entre 65 MeV et 2,7 GeV. Ces valeurs ont permis de prevoir des quantites mesurables de carbone 14 dans les meteorites et par suite de les determiner. D'autre part les reaction {sup 12}C({sup 16}O...), {sup 12}C({sup 14}N...) et {sup 12}C({sup 12}C...) ont ete etudiees et on a tente d'expliquer le mecanisme de ces reactions. (auteur)

  2. Burst slug detection system in french power reactors (1961); La detection des ruptures de gaines dans les reacteurs de puissance francais (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Megy, J; Roguin, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    Gas samples are taken from the channels of the reactor and the short lived fission products are electrostatically collected to be analysed by a phosphor and photomultiplier system. The electrostatic collection and rotating electrode detector is described and its main uses exposed. Experience has shown the interest of measuring the evolution of fission products activities and not their absolute value only. In this way, data processing equipment have been designed and adapted to the detection apparatus. The system developed and realized for the G-l - G-2 - G-3 - EDF-1 - EDF-2 reactors are compared. (authors) [French] Un prelevement de gaz est effectue dans les canaux du reacteur et les produits de fission a vie courte sont collectes electrostatiquement pour etre analyses par un ensemble scintillateur-photomultiplicateur. Le detecteur a collection electrostatique et electrode tournante est decrit et ses applications principales sont exposees. L'experience a montre l'interet de mesurer l'evolution des activites en produits de fission et non seulement leur valeur absolue. D'ou le developpement d'ensembles de traitement des informations associes aux chaines de detection. Comparaison des realisations sur les reacteurs G-l - G-2 - G-3 - EDF-1 et EDF-2. (auteurs)

  3. Present Status of Nitrogen Fixation by Reactor Radiation; Etat Actuel des Recherches sur l'oxydation directe de l'azote sous irradiation dans des reacteurs; Sovremennoe sostoyani opytov po okisleniyu azota izlucheniem iz reaktorov; Estado actual de las investigaciones sobre fijacion del nitrogeno por irradiacion en reactores

    Energy Technology Data Exchange (ETDEWEB)

    Harteck, P; Dondes, S [Rensselaer Polytechnic Institute, Troy, NY (United States)

    1960-07-15

    Investigations in nitrogen fixation by reactor radiation which have been carried out at Rensselear and Brookhaven National Laboratory for a number of years, have used the fission recoil energy directly as ionizing radiation by means of the dispersion of U{sup 235} in glass fibers about five microns in diameter. The effects of temperature, pressure and nitrogen-oxygen ratio on the G-value for nitrogen fixation have been determined and reported in the literature. A brief summary of this work is given. The above work has been done in static systems; more recent work has involved both static and flow systems. In static systems, major emphasis has been placed on the effect of radiation intensity especially at the kinetic radiation equilibrium. It has been found that the production of N0{sub 2} and N{sub 2}0 in 4:1 and 2:1 nitrogen-oxygen mixtures proceeds to the point of total oxygen consumption. A flow (cycling) system is now operating in a loop in the Brookhaven reactor. Data are presented on the effects of temperature, pressure, mixture ratio and radiation intensity which may be applied to the design of a future chemonuclear reactor. The present system is operating at 10 atmospheres and 150{sup o}C. The temperature is a function of the fission energy released in the glass fibers and the heat resistance of the loop. Another loop to operate at 50 - 75 atmospheres and 600{sup o}C is under construction. These loops make possible the evaluation of the characteristics of a continuous system, including the behaviour of the fission products released in the gas stream. The complicated kinetics of nitrogen oxidation are outlined in three stages: initial reactions in the systems, reactions after some fixed nitrogen has been produced, and finally the kinetics at radiation equilibrium. The conditions for the formation of N{sub 2}0{sub 3}, N{sub 2}0{sub 4} and O{sub 3} are considered, together with their effects and the overall process. (author) [French] Des recherches sur l

  4. Management of ionizing radiation sources in university, medical and industrial environments; Gestion des sources ionisantes en milieux universitaire, medical et industriel

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    This conference treats several subjects relative to the use of radioactive sources. The first session comprises three articles about ionizing sources and regulation. The second session, with three articles, tackles the question of radiation protection in the use of sources in industrial field. The third session, four articles, treats the same question but in the medicine and university media. The fourth session (three articles) is devoted to the organisation of radiation protection in the case of accidents. The fifth session concerns the management of spent sources (three articles). The sixth session studies the radiation protection of sources in Europe. The seventh and final session ends with the part and coordination of actors in radiation protection in the sources management (three articles). (N.C.)

  5. Prevention of risks in relation with occupational exposure to ionizing radiation; Prevention des risques lies a l'exposition professionnelle aux rayonnements ionisants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    After remind the base notions in the field of ionizing radiation, this file evaluates the situation on the natural and occupational exposures: modes, sources, and exposure level, risk for health. It presents the principles of prevention allowing in a professional area (out of nuclear industry) to reduce and control these exposures. Some practical cases illustrate the radiation protection approach. references are given: regulatory benchmarks, useful links, books to consult. (N.C.)

  6. Development of nuclear medicine techniques - radiation protection issues for patients; Evolution des techniques en medecine nucleaire - Enjeux de radioprotection pour les patients

    Energy Technology Data Exchange (ETDEWEB)

    Marchandise, Xavier [Faculte de Medecine de Lille, F-59045 Lille Cedex (France)

    2011-07-15

    Nuclear medicine uses radioactive isotopes for diagnostic or therapeutic purposes. The radiation protection culture is now well-anchored in the training of nuclear medicine specialists in France and must remain at the highest possible level. However, practices change and the immediate medical - or even media - interest in new equipment and new tracers must not obscure the fundamentals of patient radiation protection. Particular vigilance is today required with regard to two aspects: - children; - the corresponding computed tomography. (author)

  7. Normal tissue tolerance to external beam radiation therapy: Esophagus; Dose de tolerance a l'irradiation des tissus sains: l'oesophage

    Energy Technology Data Exchange (ETDEWEB)

    Bera, G.; Pointreau, Y. [Clinique d' oncologie-radiotherapie, centre Henry-S.-Kaplan, hopital Bretonneau, CHU de Tours, 37 - Tours (France); Denis, F.; Dupuis, O. [Centre Jean-Bernard, clinique Victor-Hugo, 72 - Le-Mans (France); Orain, I. [Service d' anatomie et cytologie pathologiques, hopital Trousseau, CHU de Tours, 37 - Tours (France); Crehange, G. [Departement de radiotherapie, centre Georges-Francois-Leclerc, 21 - Dijon (France)

    2010-07-15

    The esophagus is a musculo-membranous tube through which food passes from the pharynx to the stomach. Due to its anatomical location, it can be exposed to ionizing radiation in many external radiotherapy indications. Radiation-induced esophageal mucositis is clinically revealed by dysphagia and odynophagia, and usually begins 3 to 4 weeks after the start of radiation treatment. With the rise of multimodality treatments (e.g., concurrent chemoradiotherapy, dose escalation and accelerated fractionation schemes), esophageal toxicity has become a significant dose-limiting issue. Understanding the predictive factors of esophageal injury may improve the optimal delivery of treatment plans. It may help to minimize the risks, hence increasing the therapeutic ratio. Based on a large literature review, our study describes both early and late radiation-induced esophageal injuries and highlights some of the predictive factors for cervical and thoracic esophagus toxicity. These clinical and dosimetric parameters are numerous but none is consensual. The large number of dosimetric parameters strengthens the need of an overall analysis of the dose/volume histograms. The data provided is insufficient to recommend their routine use to prevent radiation-induced esophagitis. Defining guidelines for the tolerance of the esophagus to ionizing radiation remains essential for a safe and efficient treatment. (authors)

  8. Measurement of the production of K{sup +} mesons by protons in nuclei (1960); Mesure de la production des mesons K{sup +} par des protons dans les noyaux (1960)

    Energy Technology Data Exchange (ETDEWEB)

    Teiger, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1960-07-01

    K{sup +} mesons produced by the internal proton beam of Saturne have been identified by means of scintillation and Cerenkov counters. The production cross sections are given per target nucleus measured at a laboratory angle of 35 deg. as well as the cross section relative to {pi}{sup +} mesons of the same momentum for: - incident protons of kinetic energy between 1.3 and 2.8 GeV, - targets of C, Cu and Pb, - K{sup +} produced with kinetic energies between 0.45 and 0.65 GeV. From these results we have tried to deduce the importance of indirect production by intermediate {pi} mesons with respect to direct production by proton-nucleon collisions. (author) [French] Au moyen de detecteurs a scintillations et a rayonnement Cerenkov, on a identifie les mesons lourds K{sup +} produits par les protons du faisceau interne de 'Saturne'. On donne les sections efficaces de production, par noyau cible, mesurees a 35 deg. dans le laboratoire, ainsi que les sections efficaces relatives par rapport aux mesons {pi}{sup +} de meme impulsion pour: - des protons incidents d'energie cinetique entre 1,3 GeV et 2,8 GeV, - des cibles de C, de Cu et de Pb, - des K{sup +} produits avec des energies cinetiques entre 0,45 et 0,65 GeV. De ces resultats, on a essaye de deduire l'importance de la production indirecte, par mesons {pi} intermediaires, par rapport a la production directe dans un choc proton-nucleon. (auteur)

  9. Data processing in gamma spectrometry. Application to the decay schemes study; Traitement des informations en spectrometrie gamma application a l'etude de schemas de desintegration

    Energy Technology Data Exchange (ETDEWEB)

    Boulanger, J.P. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires, departement d' electronique generale, service d' instrumentation nucleaire

    1968-06-01

    The purpose of this thesis is the processing of the data issued from a gamma spectrometer, and its applications to the decay schemes study. The mathematical analysis of the full energy peaks, in connection with the very good resolution of semi-conductor detectors, leads to a very accurate determination of the energies. The resolution of complex spectra by the least squares method, completed by a spectra generating process, allows the calculation of branching ratios. Then, the handling of the two dimensional experiments permits the coincidence exam. For each of these methods, the calculation principle, then the systematics tests realized in order to prove their validity and to determine their application ranges as well as some experimental results appropriate to illustrate their possibilities, are presented. The energies of some nuclides, frequently used as standards have been thus measured and the decay schemes of {sup 134}Cs and {sup 110m}Ag determined precisely. (author) [French] Cette these est consacree aux methodes de traitement des informations issues d'un spectrometre {gamma}, et a leur application a l'etude des schemas de desintegration: l'analyse mathematique des pics d'absorption totale, conjuguee avec l'excellent pouvoir de resolution des detecteurs semi-conducteurs, conduit a une determination tres precise des energies. La decomposition des spectres complexes par la methode des moindres carres, completee par un procede de generation de spectres, autorise le calcul des rapports de branchement. Enfin le depouillement des experiences biparametriques permet l'examen des coincidences. Pour chacune de ces methodes, on expose le principe des calculs et les essais systematiques effectues afin d'eprouver leur validite et de definir leurs domaines d'application, ainsi que quelques resultats experimentaux propres a illustrer leurs possibilites. Les energies de quelques isotopes utilises couramment comme etalons ont ainsi ete

  10. Instruments used to measure or check {alpha}, {beta}, {gamma} activity and neutron emission in the course of processing ore or irradiated fuel; Appareils de mesure ou de controle {alpha}, {beta}, {gamma}, n, des circuits des usines de traitement du minerai ou du combustible irradie

    Energy Technology Data Exchange (ETDEWEB)

    Blanc, A; Brunet, M; Kermagoret, M; Labeyrie, J; Roux, G; Vasseur, J; Weil, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1959-07-01

    plutonium et des produits de fission dans les differents circuits, et sur la radioactivite des effluents rejetes par l'usine dans les cours d'eau. Le controle des operations de fixation et d'elution de l'uranium est effectue automatiquement par un appareil qui preleve, evapore et mesure l'activite {alpha} de 5 cm{sup 3} de solution toutes les 10 ou 20 minutes. Les teneurs en plutonium sont mesurees: - en presence de fortes activites {beta} {gamma} par des detecteurs {alpha} a cylindres tournants; - en presence de faibles activites {beta} {gamma} par des detecteurs {alpha} examinant une surface liquide a niveau constant; - par des chambres a fission peu sensibles aux {gamma}. Les teneurs en produits de fission sont mesurees par des chambres, compteurs, ou scintillateurs, selon l'importance de l'activite {gamma}. Enfin, le controle de l'activite des effluents a rejeter dans les cours d'eau est realise par un appareil a scintillation mesurant l'activite {alpha} d'une part et, d'autre part l'activite {alpha} {gamma} des residus d'un echantillon de 100 cm{sup 3} preleve et evapore en 20 minutes. (auteur)

  11. Identification de l'Électron à D0

    Energy Technology Data Exchange (ETDEWEB)

    Pluquet, Alain [Pierre and Marie Curie Univ., Paris (France)

    1994-01-01

    Cette théetudie les techniques d'identication de l'electron dans l'experience D0 au laboratoire Fermi pres de Chicago Le premier chapitre rappelle quelques unes des motivations physiques de l'experience physique des jets physique electrofaible physique du quark top Le detecteur D0 est decrit en details dans le second chapitre Le troisieme cha pitre etudie les algorithmes didentication de lelectron trigger reconstruction ltres et leurs performances Le quatrieme chapitre est consacre au detecteur a radiation de transition TRD construit par le Departement dAstrophysique Physique des Particules Physique Nucleaire et dInstrumentation Associee de Saclay il presente son principe sa calibration et ses performances Enn le dernier chapitre decrit la methode mise au point pour lanalyse des donnees avec le TRD et illustre son emploi sur quelques exemples jets simulant des electrons recherche du quark top

  12. Improvements of the sensitivity of burst cartridge detection; Amelioration du seuil de detection des ruptures de gaine

    Energy Technology Data Exchange (ETDEWEB)

    Vasnier, F [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    I - Special tests for improving the sensitivity of burst cartridge detection equipment in power reactors II - Scintillator purge-flow tests using aged gas in the B.C.D. /E.D.F. 2 Summary. - The first part of this report describes the tests carried out on fission product detectors by a process in which gas is continuously injected in front of the scintillator. Using this system, the background is reduced and perturbations caused by pneumatic switches on the prospecting circuits are eliminated. The quality of the signals thus obtained permits better processing of the data and thus leads to a possible improvement in the sensitivity of burst cartridge detection. The second part gives results of tests carried out with both fresh and aged gases, the economic advantage of the latter being that it permits recycling through the reactor. Reduction of the background is less pronounced but the advantage of the stable signals is conserved. (author) [French] I - Essais speciaux pour ameliorer le seuil de detection des installations de D.R.G. des reacteurs de puissance II- Essais de balayage sous scintillateur avec gaz vieilli a la D.R.G. /E.D.F. 2 Sommaire. - La premiere partie de ce rapport decrit les essais effectues sur les detecteurs de produits de fission par un procede d'injection continue de gaz sous le scintillateur. Grace a ce systeme on obtient une reduction du bruit de fond et l'elimination des perturbations causees par les commutations pneumatiques des circuits de prospection. La qualite des signaux obtenus ainsi permet un meilleur traitement des informations d'ou une amelioration possible du seuil de detection des ruptures de gaines. La seconde partie donne les resultats d'essais effectues avec du gaz propre et vieilli, l'utilisation de ce dernier presentant l'avantage economique d'etre recycle du reacteur. La reduction du bruit de fond est moins importante mais on conserve l'avantage de la stabilisation des signaux. (auteur)

  13. Can rupture detector for water cooled piles; Detecteur de rupture de gaine pour piles refroidies a l'eau

    Energy Technology Data Exchange (ETDEWEB)

    Choudens, H de; Guitton, P

    1962-07-01

    The object of this study was to develop a simple, easy to-build, apparatus for showing the appearance of a defect on a fuel element can of a swimming pool reactor. The apparatus used consists of a coil of activated carbon around a NaI(Tl) crystal. Through this coil pass the gases obtained by degassing a sample of water from the reactor; the fission gases which appear when a can leaks are trapped in the carbon; the NaI(Tl) crystal is coupled with a photomultiplier followed by a single-channel selector fixed on a photo-electric peak characteristic of the {gamma} spectrum of fission gases. Preliminary experiments were carried out in laboratory; a more complete device was then built and is now working in the reactor Melusine. (author) [French] Le but de cette etude a ete la realisation d'un appareil simple et facile a realiser destine a indiquer l'apparition d'un defaut sur une gaine des elements combustibles d'une pile piscine. A cet effet, l'appareillage utilise est compose d'un serpentin de charbon active entourant un cristal de NaI (Tl). Ce serpentin est parcouru par les gaz provenant du degazage d'un prelevement d'eau de la piscine du reacteur; les gaz de fission apparaissant lors d'une rupture de gaine sont retenus dans le charbon; le cristal INa (Tl) est couple avec un PM suivi d'un selecteur monocanal cale sur un pic photoelectrique caracteristique du spectre {gamma} des gaz de fission. Des manipulations preliminaires ont ete faites en laboratoire, un dispositif plus complet a ete ensuite monte et fonctionne a la Pile Melusine. (auteurs)

  14. Mesenchymal stem cells favour healing of the cutaneous radiation syndrome; Les cellules souches mesenchymateuses favorisent la cicatrisation des lesions cutanees radio induites

    Energy Technology Data Exchange (ETDEWEB)

    Francois, S.; Mouiseddine, M.; Mathieu, N.; Semont, A.; Monti, P.; Dudoignon, N.; Sache, A.; Boutarfa, A.; Thierry, D.; Voisin, P.; Gourmelon, P.; Chapel, A. [IRSN, Dir. de radioprotection de l' Homme, 92 - Fontenay-aux-Roses (France)

    2006-10-15

    It has been suggested that human Mesenchymal Stem Cells (hMSC) could be used to repair numerous injured tissues. We have studied the potential use of hMSC in order to limit radiation-induced skin lesions. Immuno-deficient NOD/SCID mice were locally irradiated to the leg (30 Gy, dose rate 2.7 Gy/mn) using a {sup 60} Co source in order to induce a severe skin lesion. Cultured bone marrow hMSC were delivered intravenously to the mice. The irradiated skin samples were studied for the presence of the human cells, the severity of the lesions and the healing process. Macroscopic analysis and histology results showed that the lesions were evolving to a less severe degree of radiation dermatitis following hMSC transplant when compared to irradiated non-transplanted controls. Clinical scores for the studied skin parameters of treated mice were significantly improved. A faster healing was observed when compared to untreated mouse. Immuno-histology and Polymerase Chain reaction (PCR) analysis provided evidence that the human cells were found in the irradiated area. These results suggest a possible use of hMSC for the treatment of the early phase of the cutaneous radiation syndrome. A successful transplant of stem cells and subsequent reduction in radiation-induced complication may open the road to completely new strategies in cutaneous radiation syndrome therapy. (authors)

  15. Environmental radioactivity in Germany. Report of the federal installations and the Federal office of radiation protection. Data and evaluation; Umweltradioaktivitaet in der Bundesrepublik Deutschland. Bericht der Leitstellen des Bundes und des Bundesamtes fuer Strahlenschutz. Stand 2014. Daten und Bewertung

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-04-15

    This report is a compilation and evaluation of data on radioactivity in the environment and in the vicinity of nuclear facilities in Germany from 2011 to 2013. The mean radiation exposure of the public in Germany was about 4.0 mSv in 2013, of which natural radiation exposure accounted for about 2.1 mSv and man-made radiation exposure for 1.9 mSv. An international work group is in charge of the preparation of quality standards for radon measurements. These latter also serve as a basis to implement the regulations of the new EURATOM Basic Safety Standards Directive. Rice grown within the contaminated zone around Fukushima has been certified as reference material for food monitoring. The trace analysis laboratory for airborne radioactive substances obtained several striking results of measurements performed during the reporting period. Man-made radionuclides from the Fukushima nuclear accident were detectable, too. Assessment of anthropogenic radioactivity also requires thorough measurement of ''natural'' radiation components. Three different measurement areas are used as a reference for calibration. Discharges of radioactive substances into the exit air and wastewaters from nuclear power plants remained far below the authorised limit from 2011 to 2013. There has been a trend of decreasing discharges since 1975. The nine nuclear power plant units in operation at the end of the reporting period had a total capacity of 12.7 GW and accounted for 15 per cent of power generation. The annual mean values provided by the measuring network of the Deutscher Wetterdienst (DWD; German Meteorological Service) amounted to 0.6 mBq/m{sup 3}, 0.7 mBq/m{sup 3} and 0.7 mBq/m{sup 3} for the total -activity in the air and 58 Bq/m{sup 2}, 38 Bq/m{sup 2}, and 27 Bq/m{sup 2} for the total -activity deposited by precipitation in 2011, 2012 and 2013, respectively. The higher annual value for 2011 is due to the Fukushima releases. The activity concentrations of {sup 85}Kr

  16. QCD-resummation and non-minimal flavour-violation for supersymmetric particle production at hadron colliders; Resommation des corrections radiatives QCD et violation de la saveur non-minimale pour la production de particules supersymetriques aupres des collisionneurs hadroniques

    Energy Technology Data Exchange (ETDEWEB)

    Fuks, B

    2007-06-15

    Cross sections for supersymmetric particles production at hadron colliders have been extensively studied in the past at leading order and also at next-to-leading order of perturbative QCD. The radiative corrections include large logarithms which have to be re-summed to all orders in the strong coupling constant in order to get reliable perturbative results. In this work, we perform a first and extensive study of the resummation effects for supersymmetric particle pair production at hadron colliders. We focus on Drell-Yan like slepton-pair and slepton-sneutrino associated production in minimal supergravity and gauge-mediated supersymmetry-breaking scenarios, and present accurate transverse-momentum and invariant-mass distributions, as well as total cross sections. In non-minimal supersymmetric models, novel effects of flavour violation may occur. In this case, the flavour structure in the squark sector cannot be directly deduced from the trilinear Yukawa couplings of the fermion and Higgs supermultiplets. We perform a precise numerical analysis of the experimentally allowed parameter space in the case of minimal supergravity scenarios with non-minimal flavour violation, looking for regions allowed by low-energy, electroweak precision, and cosmological data. Leading order cross sections for the production of squarks and gauginos at hadron colliders are implemented in a flexible computer program, allowing us to study in detail the dependence of these cross sections on flavour violation. (author)

  17. Stereotactic body radiation therapy (SBRT) in the treatment of liver metastases: State of the art; Radiotherapie en conditions stereotaxiques des metastases hepatiques

    Energy Technology Data Exchange (ETDEWEB)

    De Bari, B.; Guillet, M.; Mornex, F. [Departement de radiotherapie oncologie, centre hospitalier Lyon-Sud, chemin du Grand-Revoyet, 69310 Pierre-Benite (France); EA3738, domaine Rockefeller, universite Claude-Bernard, 8, avenue Rockefeller, 69373 Lyon cedex 08 (France)

    2011-02-15

    Liver metastases are frequently found in oncologic patients. Chemotherapy is the standard treatment in pluri-metastatic patients, with the possibility to obtain a clear improvement of their prognosis. Local treatment (surgery, radiofrequency, cryo-therapy, radiotherapy, etc.) could be proposed for oligo-metastatic patients, particularly for those with a good prognosis. Historically, radiation therapy has had a limited role in the treatment of liver metastases because of its toxicity when whole liver irradiation was delivered. Improvements in the knowledge of liver radiobiology and radio-pathology as well as technical innovations in delivering radiation therapy are the basis of the modern partial liver irradiation concept. In this historical and therapeutic landscape, extracranial stereotactic radiation therapy is particularly interesting for the treatment of liver metastases. This review summarises published data on stereotactic radiotherapy for the treatment of liver metastases. (authors)

  18. Étude des détecteurs planaires pixels durcis aux radiations pour la mise à jour du détecteur de vertex d'ATLAS

    CERN Document Server

    Benoit, Mathieu

    In this work, is presented a study, using TCAD simulation, of the possible methods of designing of a planar pixel sensors by reducing their inactive area and improving their radiation hardness for use in the Insertable B-Layer (IBL) project and for SLHC upgrade phase for the ATLAS experiment. Different physical models available have been studied to develop a coherent model of radiation damage in silicon that can be used to predict silicon pixel sensor behavior after exposure to radiation. The Multi-Guard Ring Structure,a protection structure used in pixel sensor design was studied to obtain guidelines for the reduction of inactive edges detrimental to detector operation while keeping a good sensor behavior through its lifetime in the ATLAS detector. A campaign of measurement of the sensor's process parameters and electrical behavior to validate and calibrate the TCAD simulation models and results are also presented. A model for diode charge collection in highly irradiated environment was developed to explain ...

  19. Radiation protection of people in contact with patient treated with metabolic radiotherapy using iodine-131 in nuclear medicine - case of the Laboratoire des Radio-Isotopes(LRI) Anpandrianomby

    International Nuclear Information System (INIS)

    RAMAROJAONA, H.

    2008-01-01

    In the aim to propose recommendations for radiation protection of those in contact with patients, simulations were performed for restricting the radiation hazards to the family and the members of the public coming into contact with a patient treated with 131 Iode for a thyroid pathology. The simulated dose constraint was 0,3 mSv for the family. According to the regulation in radiation protection in Madagascar, annual dose limit for the public is 1mSv and 20 mSv for the workers. Several contact patterns were tested: contact to the workers, daily visits, public transports, return to work, sleeping with partner and close contact with children. The recommendations duration was evaluated both as a function of the administered activity (out-patient) or the residual activity (discharged inpatient) by measuring the dose rate at 1 m distance from the patient. [fr

  20. Modification of the refractive index of dielectrica by means of ionizing radiation; Modifikation des Brechungsindexes von Dielektrika mit Hilfe ionisierender Strahlung

    Energy Technology Data Exchange (ETDEWEB)

    Andreas, B.

    2005-05-01

    Refractive-index changes are studied, which result by interaction of ionizing radiation with dielectric, optically transparent solids. As examples two materials are studied. At the one hand it deals with polymethylmethacrylate (PMMA), a polymer, which is irradiated with synchrotron radiation, and at the other hand with lithium niobate (LiNbO{sub 3}), an oxidic crystal, which is irradiated by fast helium ions. In both materials refractive-index changes in the range 10{sup -4} to 10{sup -3} can be produced, which is very interesting for many applications in photonics.

  1. Interest of blood markers in predicting radiation-induced toxicity; Interet des marqueurs sanguins dans la prediction de la toxicite radio-induite

    Energy Technology Data Exchange (ETDEWEB)

    Lacombe, J. [Departement de cancerologie radiotherapie, CRLC Val-d' Aurelle-Paul-Lamarque, rue Croix-Verte, 34298 Montpellier cedex 5 (France); Universite de Montpellier I, 5, boulevard Henri-IV, CS 19044, 34967 Montpellier cedex 2 (France); Laboratoire d' oncoproteomique clinique, CRLC Val-d' Aurelle-Paul-Lamarque, rue Croix-Verte, 34298 Montpellier cedex 5 (France); Solassol, J. [Laboratoire de biologie cellulaire et hormonale, hopital Arnaud-de-Villeneuve, CHU de Montpellier, 371, avenue du Doyen-Gaston-Giraud, 34295 Montpellier cedex 5 (France); Laboratoire d' oncoproteomique clinique, CRLC Val-d' Aurelle-Paul-Lamarque, rue Croix-Verte, 34298 Montpellier cedex 5 (France); Coelho, M. [Inserm U896, institut de recherche en cancerologie de Montpellier, CRLC Val-d' Aurelle-Paul-Lamarque, rue Croix-Verte, 34298 Montpellier cedex 5 (France); Ozsahin, M. [Service de radio-oncologie, centre hospitalier universitaire Vaudois, 1011 Lausanne (Switzerland); Azria, D. [Departement de cancerologie radiotherapie, CRLC Val-d' Aurelle-Paul-Lamarque, rue Croix-Verte, 34298 Montpellier cedex 5 (France); Universite de Montpellier I, 5, boulevard Henri-IV, CS 19044, 34967 Montpellier cedex 2 (France); Inserm U896, institut de recherche en cancerologie de Montpellier, CRLC Val-d' Aurelle-Paul-Lamarque, rue Croix-Verte, 34298 Montpellier cedex 5 (France)

    2011-08-15

    The oncologic outcome and the total dose are highly correlated with the treatment by ionizing radiation. The dose increase (total or per fraction) may provoke late-side effects that are potentially irreversible. The radiation-induced CD8 lymphocyte apoptotic value and the molecular modifications within the lymphocyte are capable of predicting the level of risk of developing late-side effects after curative intent radiotherapy. In this review, we present the different blood assays in this setting and discuss the current possibilities of researches, namely those involving the proteomic process. (authors)

  2. Effects of Gamma Radiation on Three Species of Philippine Insect Pests; Effets des rayons gamma sur trois especes d'insectes nuisibles des Philippines; Dejstvie gamma-izlucheniya na tri raznovidnosti nasekomykh-vreditelej na Filippinakh; Efectos de las radiaciones gamma sobre tres plagas insectiles de las Filipinas

    Energy Technology Data Exchange (ETDEWEB)

    Viado, G. B.; Manoto, E. C. [Philippine Atomic Energy Commission, National Science Development Board, Manila (Philippines)

    1963-09-15

    A study was conducted on the effects of gamma radiation from a Co{sup 60} source on three agricultural insect pests, namely (1) the tomato lady beetle, Epilachna philippinensis Dieke, a pest of tomato and eggplant; (2) the rice weevil, Sitophilus oryzae L.; and (3) the rust-red flour beetle, Tribolium castaneum Herbst. The last two species are the most common and most destructive pests of corn and other stored grains and grain products in the Philippines. Eggs, larvae, pupae and adults of E. philippinensis on tomato and adults of S. oryzae and T. castaneum on corn were used. Four doses were used on Epilachna, namely 1, 5, 10 and 20 kr. In the other two species, five doses were used, 10, 20, 40, 60 and 80 kr. At 1 kr, the proportion of unhatched eggs in Epilachna was about 10%. There was no proportionate increase in mortality at 5 kr, but at 10 kr the mortality increased to more than three times that at 5 kr. Mortality at 20 kr was about 90%. The threshold dose seems to lie between 5 and 10 kr. The embryo of eggs that did not hatch failed to continue development. At 1 kr, over 20% of the larvae were killed, although some of these succeeded in pupating before they died. Most of the larvae attained the adult stage, All the larvae that survived the treatments above 1 kr, some for.as long as four weeks, died without attaining the pupal stage. The pupae were more resistant than the larvae and the adults. Complete mortality was not attained even with 20 kr. Some adults which emerged in the 5-kr and 10-kr lots had abnormally developed wings and/or legs. In the adults, the 10 and 20 kr doses had an adverse effect, killing about 75% of the individuals subjected to the lower, and all subjected to the higher, dose three weeks after irradiation. No significant difference in susceptibility between the sexes was noted. About 40% of the S. oryzae in the lots treated with 60 and 80 kr were killed one week after irradiation, but only about 10% were killed with 20 kr and about 2 0

  3. The transition radiation. I: numerical study of the angular and spectral distributions; Le rayonnement de transition optique. I: etude numerique des distributions angulaires et spectrales

    Energy Technology Data Exchange (ETDEWEB)

    Couillaud, Ch.; Haouat, G

    1999-07-01

    The optical transition radiation (OTR) is extensively used since many years as a beam visualisation tool on electron accelerators and serves to monitor the beam during its transport adjustment. Its spatial and temporal characteristics make it very attractive as a diagnostic tool and allow measurements of the beam energy and transverse and longitudinal emittances. We present a numerical study of the transition radiation process in the optical region of the radiated spectrum (OTR) and in the higher part (XTR). Spatial and spectral properties are described. They are used to describe experimental observations performed on the ELSA electron-beam facility. An analytical description of the angular distributions of visible radiation emitted by birefringent targets, used as OTR sources, is also proposed. We also analyze interference phenomena between two OTR sources and show the advantage of using this interferometer as a diagnostic tool for tenth MeV electron accelerators. At last, we present an analytical model allowing to design a soft X-ray source to be installed on the ELSA facility and using either a multi-foil stack or a multilayer of two materials of different permittivities. (authors)

  4. Optimization of the workers radiation protection in the electro nuclear, industrial and medical fields; Optimisation de la radioprotection des travailleurs dans les domaines electronucleaire, industriel et medical

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-07-01

    This conference is devoted to the radiation protection and the best way to optimize it. It reviews each area of the nuclear industry, and explores also the medical sector. Dosimetry, ALARA principle and new regulation are important points of this meeting. (N.C.)

  5. Investigation of inactivation of Clostridium botulinum toxin by nuclear radiation. Final report. Untersuchung zur Desaktivierung des Clostridium botulinum Toxins durch Kernstrahlung. Endbericht

    Energy Technology Data Exchange (ETDEWEB)

    Kaltenhaeuser, A.; Werner, K.H.

    1989-01-01

    The effect of nuclear radiation on the toxicity and the molecular structure of the toxin produced by the microorganism Clostridium botulinum type A was investigated. The radiation induced changes in the structure of the toxin molecule. This effect is influenced by the composition or the medium above the toxin solution as well as by the temperature during the irradiation. The results of the investigation indicate that with increasing irradiation dose a new molecule was formed with immunological properties similar to the properties of the original molecule however with a greater molecular weight. After exposure to a radiation dose of 3,4 Mrad at normal temperature in air, complete detoxification of the substance was found. Immunizing experiments with the toxoid with two guinea-pigs indicated a pronounced increase of the antibody titer in the serum after 4 weeks. Vaccination experiments with the toxoid on animals show, that the protection against the effect of the toxin corresponds to the demands of the European Pharmacopoeia. The efficiency of the toxoid shows a similar efficiency as toxoids produced by chemical methods. The production of a toxoid-viccine with the relatively simple method of nuclear radiation appears possible. (orig./MG) With 12 refs., 3 tabs., 11 figs.

  6. 8. national congress of radiation protection 'SFRP 2011' - Proceedings; Huitieme congres national de radioprotection 'SFRP 2011' - Recueil des presentations

    Energy Technology Data Exchange (ETDEWEB)

    Souques, M.; Lambrozo, J.; Perrin, A.; Magne, I.; Bedja, M.; Fleury, G.; Le Brusquet, L.; Barbe, R.; Lahaye, T.; Laurier, D.; Tomasek, L.; Tirmarche, M.; Guseva Canu, I.; Garsi, J.P.; Caer-Lorho, S.; Jacob, S.; Acker, A.; Fernandez, F.; Bertho, J.M.; Synhaeve, N.; Stefani, J.; Desbree, A.; Blanchardon, E.; Dublineau, I.; Petitot, F.; Lestaevel, P.; Tourlonias, E.; Mazzucco, C.; Jacquinot, S.; Dhieux, B.; Delissen, O.; Tournier, B.; Gensdarmes, F.; Godet, J.L.; Perrin, M.L.; Saad, N.; Bardelay, C.; Voytchev, M.; Doursout, T.; Chapalain, E.; Dandrieux, G.; Cazala, C.; Gay, D.; Chabanis, O.; Palut-Laurent, O.; Ringeard, C.; Thomassin, A.; Roxin, A.M.; Gschwind, R.; Makovicka, L.; Roxin, I.; Henriet, J.; Martin, E.; Klopfenstein, J.F.; Lochard, J.; Guillaumont, R.; Marignac, Y.; Petitfrere, M.; Catelinois, O.; Devin, P.; Sene, M.; Barbey, P.; Reaud, C.; Schneider, T.; Achikian, S.; Le Clerc, A.; Rochereau, S.; Schneider, C.; Vigneron, H.; Charron, S.; Delattre, A.; Luccioni, C.; Monti, P.; Bernaud, J.Y.; Michielsen, N.; Bondiguel, S.; Bordy, J.M.; Daures, J.; Denoziere, M.; Gualdrini, G.; Mariotti, F.; Barre, A.; Beauval, A.; Davi, J.N.; Dupic, S.; Grincourt, D.; Kandil, A.; Marteel, C.; Vrammout, D.; Saintamon, F.; Aberkane, J.; Paquet, F.; Barbey, P.; Bardies, M.; Biau, A.; Blanchardon, E.; Chetioui, A.; Lebaron-Jacobs, L.; Pasquier, J.L.; Broggio, D.; Beurrier, J.; Farah, J.; Franck, D.; Sauget, M.; Bertrand, A.; Boveda, S.; Bar, O.; Brezin, A.; Maccia, C.; Bernier, M.O.; Struelens, L.; Carinou, E.; Dominiek, J.; Brodecki, M.; Donadille, L.; Ferrari, P.; Koukorava, C.; Krim, S.; Nikodemova, D.; Ruiz-Lopez, N.; Sans Merce, M.; Vanhavere, F.; Clairand, I.; Bordy, J.M.; Debroas, J.; Ginjaume, M.; Itie, C.; Krim, S.; Lebacq, A.L.; Martin, P.; Struelens, L.; Sans-Merce, M.; Vanhavere, F.; Gauron, C.; Wild, P.; Grzebyk, M.; Derock, C.; Champion, K.; Cohen, P.; Menez, C.; Tellart, A.S.; Thiel, H.; Pennarola, R.; Choudat, D.; Dillenseger, P.; Rehel, J.L. [and others

    2011-06-15

    This document brings together the available presentations (slides) given at the 8. national congress of the French society of radiation protection SFRP and dealing with: 1 - Electro-hypersensitivity syndrome as seen by French physicians; 2 - French population exposure to 50 Hz magnetic field: main findings from EXPERS study; 3 - Regulation relative to workers protection against artificial optical radiation risks; 4 - Radon-related full-life risk; 5 - Risk of Cardiovascular disease mortality in a cohort of French uranium conversion workers potentially exposed to low uranium doses via inhalation; 6 - Epidemiological study in the vicinity of nuclear facilities in Spain; 7 - Comparison of absorbed doses after contamination by chronic ingestion of {sup 137}Cs or {sup 90}Sr; 8 - Uranium nano-particulates biokinetics after inhalation; 9 - Evolution of radiation protection basic standards at the European scale; 10 - Present day situation of radiation protection applied to instrumentation standardisation in CEI's and CENELEC's international bodies; 11 - Revision of the guidebook about the management of potentially contaminated sites: new approach elements; 12 - Distance training platform for medical radiation protection; 13 - Stakeholders involvement in uranium mining sites management: the GEP-Limousin experience; 14 - Radiation protection workshops: experience of the Notre Dame high school of Boulogne-Billancourt; 15 - Implementation of a citizen workshop about radon in private housing; 16 - Thoron influence on radon measurement in air - the case of a ionization chamber; 17 - Application of the equivalent dose concept for the lens of the eye; 18 - The radiation protection supervisory position - experience feedback from 3 partial visits at the Gravelines NPP; 19 - Evaluation and management of risks linked with the exposure to Auger and beta emitting radionuclides; 20 - Development of an extended man's phantom library: method and results; 21 - Use of computer

  7. Contribution to the study of the ionization and heating of gases by laser radiation; Contribution a l'etude de l'ionisation et du chauffage des gaz par le rayonnement d'un laser declenche

    Energy Technology Data Exchange (ETDEWEB)

    Veyrie, P [Commissariat a l' Energie Atomique, Limeil-Brevannes (France). Centre d' Etudes

    1968-01-01

    The ionization and heating of gases by the concentrated radiation of a neodymium laser is studied. The power is 300 MW, the gas studied is primarily deuterium between 300 mm and 2280 mm. The first part concerns a certain number of experimental results on the absorption of the radiation and on changes produced in the plasma as a function of time. From these results are deduced a certain number of consequences, amongst which may be mentioned the definition of a pre-ionization threshold. These experimental results are interpreted in the second part. A calculation is made of the length of the period during which the electrons multiply up to when the absorption becomes measurable. The last phase corresponds to the hydrodynamics evolution, the calculations are compared with the experiments. The agreement between theory and experiment is satisfactory for the different phases. (author) [French] On etudie l'ionisation et le chauffage des gaz par le rayonnement concentre d'un laser au neodyme. La puissance est de 300 MW, le gaz etudie est principalement le deuterium entre 300 mm et 2280 mm. La premiere partie concerne un certain nombre de resultats experimentaux. Il s'agit de l'absorption du rayonnement et de l'evolution chronologique du plasma. De ces resultats on deduit un certain nombre de consequences parmi lesquelles il faut citer la definition d'un seuil de preionisation. Ces resultats experimentaux sont interpretes dans la deuxieme partie. On calcule la duree de la phase pendant laquelle se multiplient les electrons jusqu'a ce que l'absorption soit mesurable. La derniere phase correspond a l'evolution hydrodynamique. Les calculs sont confrontes avec l'experience. L'accord entre theorie et experience est satisfaisant pour les differentes phases. (auteur)

  8. Contribution to the study of the ionization and heating of gases by laser radiation; Contribution a l'etude de l'ionisation et du chauffage des gaz par le rayonnement d'un laser declenche

    Energy Technology Data Exchange (ETDEWEB)

    Veyrie, P. [Commissariat a l' Energie Atomique, Limeil-Brevannes (France). Centre d' Etudes

    1968-01-01

    The ionization and heating of gases by the concentrated radiation of a neodymium laser is studied. The power is 300 MW, the gas studied is primarily deuterium between 300 mm and 2280 mm. The first part concerns a certain number of experimental results on the absorption of the radiation and on changes produced in the plasma as a function of time. From these results are deduced a certain number of consequences, amongst which may be mentioned the definition of a pre-ionization threshold. These experimental results are interpreted in the second part. A calculation is made of the length of the period during which the electrons multiply up to when the absorption becomes measurable. The last phase corresponds to the hydrodynamics evolution, the calculations are compared with the experiments. The agreement between theory and experiment is satisfactory for the different phases. (author) [French] On etudie l'ionisation et le chauffage des gaz par le rayonnement concentre d'un laser au neodyme. La puissance est de 300 MW, le gaz etudie est principalement le deuterium entre 300 mm et 2280 mm. La premiere partie concerne un certain nombre de resultats experimentaux. Il s'agit de l'absorption du rayonnement et de l'evolution chronologique du plasma. De ces resultats on deduit un certain nombre de consequences parmi lesquelles il faut citer la definition d'un seuil de preionisation. Ces resultats experimentaux sont interpretes dans la deuxieme partie. On calcule la duree de la phase pendant laquelle se multiplient les electrons jusqu'a ce que l'absorption soit mesurable. La derniere phase correspond a l'evolution hydrodynamique. Les calculs sont confrontes avec l'experience. L'accord entre theorie et experience est satisfaisant pour les differentes phases. (auteur)

  9. Intensity-modulated radiation therapy for head and neck cancers with bilateral irradiation of the neck: preliminary results; Radiotherapie conformationnelle avec modulation d'intensite des cancers des voies aerodigestives superieures avec irradiation bilaterale du cou: resultats preliminaires

    Energy Technology Data Exchange (ETDEWEB)

    Lapeyre, M.; Mege, A.; Mege, P.; Racadot, S.; Marchal, C. [Centre Alexis-Vautrin, Dept. de radiotherapie, avenue de Bourgogne, Unite de radiotherapie externe, 54 - Vandoeuvre-les-Nancy (France); Marchesi, V.; Aletti, P.; Noel, A. [Centre Alexis-Vautrin, Dept. de radiotherapie, avenue de Bourgogne, Unite de radiophysique, 54 - Vandoeuvre-les-Nancy (France); Noel, A.; Marchal, C. [Institut National Polytechnique de Lorraine, Universite Henri-Poincare, Centre de Recherche en Automatique de Nancy, UMR CNRS 7039 Nancy-I, 54 - Vandoeuvre-les-Nancy (France)

    2004-06-01

    Purpose. - To report preliminary results of a prospective study of intensity-modulated radiotherapy (IMRT) for head and neck squamous cell carcinoma (HNC) with bilateral irradiation of the neck. Patients and methods. - At the Alexis Vautrin Cancer Center, 23 patients have been treated with IMRT for HNC since January 2002-August 2003. The first 10 patients with a minimum follow-up of 3 months were analyzed. All tumors were oropharyngeal. There were four females and six males, with a mean age of 50 years (range 39-66). Stages were I-II in eight and III-IV in two. CTV1 was microscopic disease and N0 neck (prescribed dose: 50 Gy) and CTV2 was macroscopic disease and the volume at risk (prescribed dose: 66-70 Gy). PTV were CTV + 5 mm. Patient's immobilization consisted of a five-point head neck shoulder thermoplastic mask. Set-up verifications were done by semi-automatically matching portal images and digitized reconstructed radiographs. IMRT used dynamic multi-leaf collimation. Five patients (group A) received 50 Gy IMRT (two post-operative and three with a brachytherapy boost with a mean dose: 27.5 Gy), and five patients (group B) received 66-70 Gy IMRT (four post-operative). Acute and late normal tissue effects were graded according to the RTOG-EORTC radiation morbidity scoring criteria. Results. - With a median follow-up of 7.4 months (range 3-18.5), no patient died or had loco-regional relapse. The displacements were <4 mm in 98% cases. CTV1 and 2 received 95% of the prescribed dose in 100% of the volume. On average the mean dose to the contralateral parotid was 25.5 Gy for group A vs. 31 Gy for group B (P = 0.09). Mean doses <26 Gy were obtained in three of five patients in group A vs. zero of five patients in group B (P = 0.04). Acute skin toxicities were grade 1 in five patients, grade 2 in four and grade 3 in one. Acute mucositis cases were grade 1 in three patients, grade 2 in five and localized grade 3 in two. At 3 months, 50% of the patients had a grade

  10. Des Connaissances Aux Politiques

    International Development Research Centre (IDRC) Digital Library (Canada)

    Les synergies ont été mises en commun au fur et à mesure des progrès de la recherche. .... Recherche normative (sur le rôle et la performance des institutions .... Système national d'information sur la gestion environnementale connecté à 19 ...... Un fort contrôle centralisé sur l'élaboration des politiques nationales peut ...

  11. Effect of Gamma Radiation on Polyethyl Acrylate; Effet des rayons gamma sur le polyethylacrylate; Dejstvie gamma-izlucheniya na akrilat poliehtila; Efectos de las radiaciones gamma sobre el poliacrilato de etilo

    Energy Technology Data Exchange (ETDEWEB)

    Heyns, H; Desreux, V [Laboratory of Physical Chemistry, University of Liege (Belgium)

    1960-07-15

    The writers studied the effect of Co{sup 60} radiation on polyethylacrylat e specimens of different molecular weights, in solution and in the solid state. The solvents used were benzene and carbon tetrachloride, and the experiments were performed at ambient temperature with and without the presence of air. No after-effect was noted when the solutions were irradiated. When the diluted solutions were irradiated with increasing doses in the presence of air, a decrease was noted in the intrinsic viscosity and the sedimentation constant. The results could be explained by degradation. The direct and indirect effects were porportional to the dose and varied in different solvents. They were also both directly proportional to the initial molecular weight of the polymer. The influence of oxygen and inhibitors was studied. Specimens were also irradiated in the solid state, when it was found that cross-linking occurred with or without the presence of oxygen, and was accompanied by a varying degree of degradation. Finally, tests made on concentrated solutions in carbon tetrachloride showed some competition between degradation and cross-linking. (author) [French] Les auteurs etudient l'effet du rayonnement du Co{sup 60} sur des echantillons d'acrylate de polyethyle de differents poids moleculares en solution et a l'etat solide. Les solvants utilises sont le benzene et le tetrachlorure de carbone; les essais sont faits a la temperature ordinaire en absence et en presence d'air. Aucun post-effet n'a ete observe lors de l'irradiation des solutions. Si l'on irradie des solutions diluees en presence d'air avec des doses croissantes, on constate que la viscosite intrinseque et la constante de sedimentation diminuent. Les resultats obtenus peuvent etre interpretes sur la base d'une degradation. L'effet direct et l'effet indirect sont proportionnels a la dose et varient d'un solvant a l'autre. Ils sont egalement tous deux directement proportionnels au poids moleculaire initial du

  12. Mutual influence between current-induced giant magnetoresistance and radiation-induced magnetoresistance oscillations in the GaAs/AlGaAs 2DES.

    Science.gov (United States)

    Samaraweera, R L; Liu, H-C; Wang, Z; Reichl, C; Wegscheider, W; Mani, R G

    2017-07-11

    Radiation-induced magnetoresistance oscillations are examined in the GaAs/AlGaAs 2D system in the regime where an observed concurrent giant magnetoresistance is systematically varied with a supplementary dc-current, I dc . The I dc tuned giant magnetoresistance is subsequently separated from the photo-excited oscillatory resistance using a multi-conduction model in order to examine the interplay between the two effects. The results show that the invoked multiconduction model describes the observed giant magnetoresistance effect even in the presence of radiation-induced magnetoresistance oscillations, the magnetoresistance oscillations do not modify the giant magnetoresistance, and the magnetoresistance oscillatory extrema, i.e., maxima and minima, disappear rather asymmetrically with increasing I dc . The results suggest the interpretation that the I dc serves to suppress scattering between states near the Fermi level in a strong magnetic field limit.

  13. Normal tissue tolerance to external beam radiation therapy: The stomach; Dose de tolerance a l'irradiation des tissus sains: l'estomac

    Energy Technology Data Exchange (ETDEWEB)

    Oberdiac, P. [Service de radiotherapie, hopital de Bellevue, CHU de Saint-Etienne, 42 - Saint-Etienne (France); Mineur, L. [Unite d' oncologie digestive et radiotherapie, institut Sainte-Catherine, 84 - Avignon (France)

    2010-07-15

    In the following article, we will discuss general issues relating to acute and late gastric's radiation toxicities. The tolerance of the stomach to complete or partial organ irradiation is more un-appreciated than for most other organs. We consulted the Medline database via PubMed and used the key words gastric - radiotherapy - toxicity. Currently, 60 Gy or less is prescribed in gastric radiation therapy. Acute clinical toxicity symptoms are predominantly nausea and vomiting. Although there is a general agreement that the whole stomach tolerance is for doses of 40 to 45 Gy without unacceptable complication, it is well established that a stomach dose of 35 Gy increases the risk of ulcer complications. (authors)

  14. The performances of natural gas infrared radiation in paints baking; Les performances de l`infrarouge gaz pour la cuisson des peintures

    Energy Technology Data Exchange (ETDEWEB)

    Lourdou, I. [Gaz de France, 75 - Paris (France). Centre d`essais de recherches sur les utilisations du gaz

    1998-04-01

    The direction of research of Gaz de France (GdF) company, in association with the centre for technical studies of aeraulic and thermal industries (CETIAT), has carried out infrared radiation baking tests on real painted parts using natural gas burners. Tests were performed on the Erica test facility. The development of the use of infrared gas burners in the mechanical industry requires an optimum use of this technology in the baking cycle. (J.S.)

  15. Mutual influence between current-induced giant magnetoresistance and radiation-induced magnetoresistance oscillations in the GaAs/AlGaAs 2DES

    OpenAIRE

    Samaraweera, R. L.; Liu, H.-C.; Wang, Z.; Reichl, C.; Wegscheider, W.; Mani, R. G.

    2017-01-01

    Radiation-induced magnetoresistance oscillations are examined in the GaAs/AlGaAs 2D system in the regime where an observed concurrent giant magnetoresistance is systematically varied with a supplementary dc-current, I dc . The I dc tuned giant magnetoresistance is subsequently separated from the photo-excited oscillatory resistance using a multi-conduction model in order to examine the interplay between the two effects. The results show that the invoked multiconduction model describes the obs...

  16. Experimental methods of reactor physics; Methodes experimentales de physique des reacteurs a neutrons thermiques

    Energy Technology Data Exchange (ETDEWEB)

    Breton, D; Lafore, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    ) Mesures par neutrons pulses: dispositif utilise et precision, application aux mesures de {lambda}t et aux mesures d'antireactivite, application au graphite, a l'eau ordinaire et au Be0. b) Mesures par oscillation (M. VIDAL): appareillage utilise et precision obtenue, application aux mesures de sections efficaces effectives et aux integrales de resonnance. c) Fluctuation: appareils utilises et techniques de mesures. III - MESURES PAR EMPOISONNEMENT. Description des methodes d'introduction et d'extraction du poison, difficultes rencontrees sur l'eau legere et sur l'eau lourde mesures des coefficients de temperature et antireactivite. IV - MESURES SPECTRALES: Choix et mise au point des detecteurs, difficultes de mesures, application aux mesures spectrales en vue d'etude de thermalisation, application a la dosimetrie. V - MESURES EXPERIMENTALES DE PROTECTION: On presente les techniques et les appareillages recemment mis au point dans ce domaine. (auteurs)

  17. Nuclear safety and radiation protection report of the Chooz nuclear facilities - 2010; Rapport sur la surete nucleaire et la radioprotection des installations nucleaires de Chooz - 2010

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-06-15

    This safety report was established under the article 21 of the French law no. 2006-686 of June 13, 2006 relative to nuclear safety and information transparency. It presents, first, the facilities of the Chooz nuclear power plant (Ardennes (FR)): 2 PWR reactors in operation (Chooz B, INB 139 and 144) and one partially dismantled PWR reactor (Chooz A, INB 163). Then, the nuclear safety and radiation protection measures taken regarding the facilities are reviewed: nuclear safety definition, radiation protection of intervening parties, safety and radiation protection improvement paths, crisis management, external and internal controls, technical situation of facilities, administrative procedures in progress. The incidents and accidents which occurred in 2010, are reported as well as the radioactive and non-radioactive (chemical, thermal) effluents discharge in the environment. Finally, The radioactive materials and wastes generated by the facilities are presented and sorted by type of waste, quantities and type of conditioning. Other environmental impacts (noise, microbial proliferation in cooling towers) are presented with their mitigation measures. Actions in favour of transparency and public information are presented as well. The document concludes with a glossary and a list of recommendations from the Committees for health, safety and working conditions. (J.S.)

  18. Nuclear safety and radiation protection report of the Flamanville nuclear facilities - 2010; Rapport sur la surete nucleaire et la radioprotection des installations nucleaires de Flamanville - 2010

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-06-15

    This safety report was established under the article 21 of the French law no. 2006-686 of June 13, 2006 relative to nuclear safety and information transparency. It presents, first, the facilities of the Flamanville nuclear power plant (Manche (FR)): 2 PWR reactors in operation (INB 108 and 109), and 1 PWR under construction (Flamanville 3, INB 167). Then, the nuclear safety and radiation protection measures taken regarding the facilities are reviewed: nuclear safety definition, radiation protection of intervening parties, safety and radiation protection improvement paths, crisis management, external and internal controls, technical situation of facilities, administrative procedures in progress. The incidents and accidents which occurred in 2010, are reported as well as the radioactive and non-radioactive (chemical, thermal) effluents discharge in the environment. Finally, The radioactive materials and wastes generated by the facilities are presented and sorted by type of waste, quantities and type of conditioning. Other environmental impacts (noise, water consumption and waste management at Flamanville 3 construction site) are presented with their mitigation measures. Actions in favour of transparency and public information are presented as well. The document concludes with a glossary and a list of recommendations from the Committees for health, safety and working conditions. (J.S.)

  19. Reactor Radiation Loops as Large Gamma Sources; Boucles d'irradiation des reacteurs nucleaires utilisees comme sources gamma intenses; Radiatsionnye kontury yadernykh reaktorov kak moshchnye gamma-istochniki; Empleo de circuitos de irradiacion de los reactores como fuentes gamma de gran intensidad

    Energy Technology Data Exchange (ETDEWEB)

    Ryabukhina, Yu. S.

    1963-11-15

    Since 1957, study and research on the' production of radiation loops has been going on in the Soviet Union. Methods for calculating such systems were worked out and the possibilities of various gamma carriers examined. Indium alloy loops, liquid at room temperature, were first selected for practical experiment. The behaviour of two eutectic indium alloys was studied in relation to certain constructional materials and at the beginning of 1960 the first test indium-gallium loop was operated. Further work led to the installation of a model indium-gallium loop in the IRT reactor of the Georgian SSR Academy of Sciences with an irradiation source activity of 100 g Ra equivalent and a test In-Ga-Sn loop in a channel of the IRT reactor at the Institute of Atomic Energy, USSR Academy of Sciences. Finally in 1962, a pilot In-Ga-Sn loop for semi-industrial radiation processes was put into service in the IRT reactor of the Latvian SSR Academy of Sciences; its maximum irradiation source activity was 30 000 g Ra equivalent. The paper has the following sections: (1) ''Radiation loop calculation'', summarizing the work done on the computation techniques involved. (2) ''A model In-Ga radiation loop for the IRT-2000 reactor in Tbilisi'', describing the loop in operation. (3) ''An In-Ga-Sn radiation loop for the Latvian SSR Academy of Sciences IRT Reactor'', describing the loop in operation. (4) ''Possibilities of further radiation loop development'', describing experiments and systems and giving calculations on the basis of which it is considered possible to build hard manganese and mobile liquid indium-alloy loops. (author) [French] Depuis 1957, on execute en Union sovietique des travaux en vue d'etudier et de construire des boucles d'irradiation. On a elabore des methodes permettant de les calculer et d'examiner les possibilites offertes par differents emetteurs gamma. Le choix a porte tout d'abord sur les boucles utilisant des alliages liquides d'indium a la temperature ambiante

  20. Two New Types of Detector for X- or Gamma-Ray Cameras; Deux Nouveaux Types de Detecteurs pour Camera a Rayons X ou {gamma}; O dvukh novykh tipov detektorov dlya rentgenovskikh ili gamma-kamer; Dos Nuevos Tipos de Detector para Camaras de Rayos X o Gamma

    Energy Technology Data Exchange (ETDEWEB)

    Kellershohn, C.; Desgrez, A. [Departement de Biologie, Service Hospitalier Frederic Joliot (France); Lansiart, A. [Departement d' Electronique, Centre d' Etudes Nucleaires de Saclay (France)

    1964-10-15

    permanently open camera. The paper discusses the characteristics of these two types of detector and the preliminary results obtained. (author) [French] Les cameras a rayons X ou {gamma} sont essentiellement constituees par une optique, stenopee ou grille, associee a un detecteur. Les auteurs proposent deux types de detecteur tout a fait differents du dispositif de'Anger, jusqu'ici le seul a avoir ete pratiquement utilise. Le premier est constitue par une chambre a etincelle auto-declenchee. Cette chambre, d'une vingtaine de centimetres de diametre et remplie d'un gaz rare (argon ou xenon), presente une cathode et deux grilles. La cathode et la deuxieme grille sont soumises a une difference de potentiel de quelques kilovolts, un peu inferieure a la tension de claquage. Le premier espace cathode-grille sert de source d'electron sous l'action des photons X ou {gamma} de faible energie. On peut egalement utiliser un placage de la cathode par un metal de Z eleve ou un cristal scintillateur associe a une photocathode. La bouffee brusque de charges due a la multiplication des electrons dans l'avalanche de Townsend declenche, apres amplification convenable, une etincelle bien localisee avec un retard d'une fraction de {mu}s. L'image est obtenue au moyen d'un appareil photographique dont l'obturateur est ouvert en permanence. Le second type de detecteur est constitue par un cristal de CsI(Tl) associe a la photocathode d'un tube Thomson a focalisation electrostatique de 20 cm de diametre. L'image sur l'ecran secondaire de ce tube est transferee au moyen d'un dispositif optique sur la photocathode d'un tube a champ electrique et magnetique parallele, de la compagnie English Electric Valve, jouant le role d'obturateur. Une partie de la lumiere penetrant dans le dispositif optique est recue par un photomultiplicateur qui commande l'ouverture du tube obturateur par l'intermediaire d'un selecteur d'amplitude. Cet artifice permet d'effectuer la selection entre la lumiere due au signal et

  1. Beta-Excited Sources of Electromagnetic Radiation; Sources de rayonnements electromagnetiques excites par des particules beta; Vozbuzhdennye beta-chastitsami istochniki ehlektromagnitnogo izlucheniya; Fuentes de radiacion electromagnetica excitadas por particulas beta

    Energy Technology Data Exchange (ETDEWEB)

    Cameron, J F; Rhodes, J R [Physics Group, Isotope Research Division, (AERE), Wantage Research Laboratory, Wantage, Berks (United Kingdom)

    1962-01-15

    Beta-excited sources of electromagnetic radiation covering the energy region 1-200 keV and suitable for industrial use are described. H{sup 3}, Pm{sup 147}, Kr{sup 85}, Tl{sup 204} and (Sr+Y){sup 90} were chosen as sources of beta particles by the criteria of long half-life, low price, ready availability and high specific activity. The {beta}-excited sources have been designed on the basis of a compromise between practical source construction and the best theoretical efficiency in a given energy region. In their paper, the authors calculate the number of photons produced per beta particle and consider how the results must be corrected for self-absorption of the X-rays. In the calculations account is taken of both bremsstrahlung and characteristic {alpha}-radiation; optimum characteristic X-ray yield is achieved for targets with an atomic number between 40 and 60. ''Sandwich'' targets of 1-2 beta half-value thicknesses are found to give maximum photon-yields in the desired energy region. Al, Ag and Au are suitable from the manufacturing point of view as source coverings. They were also found to give satisfactory bremsstrahlung and X-ray yields and distribution for various energy regions in the range 1-200 keV when correctly combined with the above-mentioned D-emitters. Some energy spectra are given and absorption curves in Al and Fe are shown for the best source-target combinations. The difference between sources constructed of {beta}-emitters sandwiched between target foils and intimate source-target mixtures was found to be small. Tables are given as a guide to the best source to be used for a particular absorber thickness range. (author) [French] Les auteurs decrivent des sources de rayonnements electromagnetiques excites par des particules beta, couvrant une gamme d'energies allant de 1 a 200 keV et convenant aux usages industriels. Comme sources de particules beta on a choisi le tritium, le {sup 147}Pm, le {sup 85}Kr, le {sup 204}Tl et le {sup 90}(Sr+Y), en

  2. Thermoluminescent Dosimeter as the Gamma Component of a Nuclear Accident Dosimeter; Utilisation du Dosimetre Thermoluminescent Comme Element Detecteur Gamma d'un Dosimetre pour les cas d'Accident Nucleaire; 0422 0415 0420 041c 0414 ; Los Detectores de Termoluminiscencia Como Elemento Gammametrico de un Dosimetro para Casos de Accidente Nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Handloser, J. S. [Edgerton, Germeshausen and Grier, Inc., Santa Barbara, CA (United States)

    1965-06-15

    Various types of gamma dosimeters have been employed as the gamma-measuring component of accident dosimeters. These have included various types of glass dosimeters, film, chemical dosimeters and polymerization dosimeters. The thermoluminescent dosimeter has notable advantages over these other types. The wide range of the thermoluminescent dosimeter permits it to be used both as a daily monitor for radiation protection purposes and as an accident dosimeter. This concept eliminates the need for special instrumentation for accident dosimeters and allows the well-calibrated instrumentation in daily use to be utilized in the accident dosimeter system. Commonly, the thermoluminescent dosimeter's inherent range is from 5 mr to 100 000 r, with a reproducibility of {+-} 10%. A single-type calcium fluoride dosimeter and associated readout equipment has been designed and manufactured to cover 5 mr to 5000 r. Readout of the dosimeter is accomplished by heating the phosphor and measuring the light output. Six decade readout instruments are available and completely automated systems have been designed. None of the readout equipment requires more than 20 seconds per dosimeter. Another advantage of the thermoluminescent dosimeter is the low neutron response. The neutron response will vary with the type of container and the type of phosphor. One type of calcium fluoride dosimeter has a neutron response of 0.27 x 10{sup -9} rad per n/cm{sup 2}. Two physical forms of the thermoluminescent dosimeter are considered. The first is an internally heated evacuated dosimeter contained in a glass envelope. This dosimeter is about 3/8-in diam.x 2 Vulgar-Fraction-One-Half -in long. The second type consists of a small-bore glass tube with the phosphor sealed inside. This dosimeter is 0.8-mm diam. x 6-mm long. Energy response correction shields have been designed for both types of dosimeter. (author) [French] L'auteur a employe divers types de cellules comme elements detecteurs des rayons gamma

  3. Évaluation des pratiques agricoles des légumes feuilles : le cas des ...

    African Journals Online (AJOL)

    SARAH

    30 sept. 2017 ... ... de Biochimie et Immunologie Appliquée, Centre de Recherche en Sciences Biologiques, Alimentaires et .... l'intoxication des agriculteurs et des consommateurs, ... source d'alimentation en eau et au pouvoir d'achat des.

  4. Measurements of the charge exchange and dissociation cross-sections of the H{sub 2}+ ion in a wide energy range; Mesures des sections efficaces d'echange de charge et de dissociation des ions H{sub 2}{sup +} dans une large gamme d'energie (25 - 250 keV)

    Energy Technology Data Exchange (ETDEWEB)

    Guidini, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1962-07-01

    The dissociation, ionisation, and charge exchange cross-sections of molecular hydrogen ions H{sub 2}{sup +} passing through various gases, have been measured as a function of the energy of the ions. The energy range studied was from 25 to 250 keV. The reaction products, analysed by a magnetic field according to their e/m ratio, are collected on scintillation detectors. Two methods have made it possible to separate the various reactions leading to the formation of particles having the same e/m ratio. The first separates the particles according to their energy, the other selects those arriving simultaneously on two different detectors. The results show a large variation in the charge exchange cross-section with the energy of the H{sub 2}{sup +} ions. The variations in the dissociation and ionisation cross-sections are less pronounced. For a given energy, the values of the cross-sections increase with the atomic weight of the target particles. These measurements have been extended to the case of H{sub 2}{sup +} ions passing through a target of charged particles. Preliminary results show an increase in the cross-sections as compared to the preceding case. Finally the scattering of the reaction products has been studied; this scattering is due to the fact that the molecules formed during a reaction are in an unstable state and the nuclei or atoms diverge from each other. (author) [French] Les sections efficaces de dissociation, d'ionisation et d'echange de charge d'ions hydrogene moleculaires H{sub 2}{sup +} traversant differents gaz, ont ete mesurees en fonction de l'energie des ions. La gamme d'energie exploree est comprise entre 25 et 250 keV. Les produits de reactions, analyses suivant leur rapport e/m par un champ magnetique, sont recus sur des detecteurs a scintillations. Deux methodes ont permis de separer les diverses reactions conduisant a la formation de particules ayant meme rapport e/m. L'une classe les particules secondaires en energie, l'autre selectionne

  5. Radiological risk assessment of isotope laboratories according to the requirements of the radiation protection ordinance and the protective labour legislation; Beurteilung des radiologischen Risikos von Isotopenlaboratorien nach den Vorgaben der Strahlenschutzverordnung und den Richtlinien fuer Arbeitssicherheit

    Energy Technology Data Exchange (ETDEWEB)

    Stuerm, R.P. [SafPro AG, Ausbildung und Beratung in Strahlenschutz, Basel (Switzerland); Kuster, M. [Novartis International AG, Corporate Health, Safety and Environment, Basel (Switzerland); Traub, K. [Novartis Pharma AG, Zentralstelle fuer Strahlenschutz, Basel (Switzerland)

    2001-07-01

    According to the Swiss Radiation Safety Ordinance the supervising authority may require a safety report from the operator of a radioactive laboratory (Art.95) and establish the methodology of the risk analysis. Isotope laboratories of the chemical industry are supervised by Swiss accident insurance agency (SUVA). In that respect SUVA safeguards both radiation protection issues and general protection of the workers and established guide lines in order to assess conventional risks in industrial premises. In these conventional analysis the working process is analysed according to its possible detriment (death, severe invalidity, slight invalidity, injury with absence, injury without absence) and the probability of occurrence (frequent, seldom, rare, improbable, virtually impossible). According to this the risks are categorised in a matrix as 'high', 'medium' and 'low'. SUVA requested such a risk analysis for two isotope laboratories of B type in Basel in which on the one hand the hazard to the workers on the other hand to the public should be analysed and radiologically assessed. It was proposed to use a methodology established in workers safety and the insurance section. This required a comparison of risks of radiation doses in mSv to the consequences of conventional working accidents (death, invalidity) and the risk perception of the public and politicians. In this paper this risk matrix derived in discussions among the supervising body, the company management, the laboratory head and workers is described. In the opinion of the authors such a comparison between radiological and conventional risks has not been performed up to now and the results obtained here are open to discussion. (orig.) [German] Gemaess schweizerischer Strahlenschutzverordnung kann die Aufsichtsbehoerde vom Inhaber einer Bewilligung zum Umgang mit radioaktiven Stoffen einen Sicherheitsbericht verlangen (Art. 95) und die Methodik der Stoerfallanalyse festlegen (Art

  6. Technical Developments in the USAEC Process Radiation Development Program; Etudes technologiques dans le cadre du programme de mise au point d'applications industrielles des rayonnements de la CEA-EU; Issledovaniya v oblasti promyshlennogo primeneniya izluchenij, vkhodyashchie v programmu komissii po atomnoj ehnergii USAEC; Progresos tecnicos en el programa de la USAEC para el fomento de la irradiacion industrial

    Energy Technology Data Exchange (ETDEWEB)

    Machurek, J. E.; Stein, M. H. [Division of Isotopes Development, USAEC, Washington, DC (United States)

    1963-11-15

    A broad range of researches have been undertaken in the USAEC 'Process radiation development program'. The primary objective of these studies is to foster development of technology leading to the productive industrial use of ionizing radiation. Results of fourteen of these investigations are reported.some in outline in this paper and some in detail in these Proceedings. The subjects included are researches on: (1) Preparation of wood-plastic combinations using gamma radiation to induce polymerization. (2) Use of fission-product beta radiation for the hydrogenation of coal and coal products to produce liquid hydrocarbon fuels. (3) Production of semi-conductor devices with the formation of predetermined spacial distribution impurity patterns via neutron transmutation doping. (4) Radiation-induced polymerization of ethylene and copolymers. (5) Basic studies in radiation-induced reaction mechanisms and kinetics. (6) Radiation chemistry involved in the fluorination of various aromatic compounds. (7) Use of polyfunctional monomers for enhanced radiation cross-linking of polyethylene, polypropylene, polyisobutylene and cellulose acetate. (8) Effect of swelling, strain and temperature on the physical and chemical properties of radiation produced polymers. (9) Radiation-induced changes in polymers leading to graft copolymerization as influenced by structural factors. (10) The utilization of nuclear radiation for the modification of textile materials. (11) Radiation-induced reactions utilizing krypton-85. (12) The preparation of a ''Radiation Handbook''. (13) Use of the organometallic bond in high level gamma radiation dosimetry. (14) The development of a solar cell dosimeter. (author) [French] Des recherches tres diverses ont ete entreprises dans le cadre du programme de mise au point d'applications industrielles des rayonnements execute par la CEA-EU. Ce programme a pour but essentiel de favoriser le developpement de la technologie en vue d'un emploi industriel productif

  7. Interest of synchrotron radiation for the therapy of brain tumors: methodology and preclinical applications; Interet du rayonnement synchrotron dans la therapie des tumeurs cerebrales: methodologie et applications precliniques

    Energy Technology Data Exchange (ETDEWEB)

    Regnard, P

    2007-12-15

    Microbeam radiation (M.R.T.) and stereotactic synchrotron radiation therapy (S.S.R.T.) are innovative techniques currently developed at the european Synchrotron radiation facility. these techniques led to promising, but rarely reproduced, results. the use of different tumoral models for each techniques limit comparisons. M.R.T. experiments on rats bearing 9L tumors 14 days after implantation displayed a double median survival time ( from 20 to 40 days) with a 200 {mu}m spacing irradiation, while a 100 {mu}m spacing irradiation tripled this median (67 days) but damaged normal tissue. the impact of the device dividing synchrotron beam into micro-beams, named multi sit collimator, was also demonstrated. combination of drugs with M.R.T. irradiation was tested. promising results (median survival time: 40 days and 30% of long term survivors) were obtained with an intratumoral injection of gadolinium coupled with a crossing M.R.T. irradiation at 460 Gy. Moreover, earlier M.R.T. irradiation (tumor at D10) quadrupled the median survival time (79 days) with 30% of long term survivors. A new imaging device to target the tumor before irradiation and an adapted collimator will increase the M.R.T. results. As the differences existing between tumoral models used in M.R.T. (9L models) and in S.S.R.T. (F98 models) are major, M.R.T./S.S.R.T. comparative experiments were realised on these two models. Results showed that the two techniques have the same efficacy on F98 model and that the M.R.T. is more effective on 9L model. This can help to define adapted tumor type for these techniques. (author)

  8. Collection of regulatory texts relative to radiation protection. Part 2: orders and decisions taken in application of the Public Health Code and Labour Code concerning the protection of populations, patients and workers against the risks of ionizing radiations; Recueil de textes reglementaires relatifs a la radioprotection. Partie 2: arretes et decisions pris en application du Code de Sante Publique et du Code du Travail concernant la protection de la population, des patients et des travailleurs contre les dangers des rayonnements ionisants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-05-15

    This collection of texts includes the general measures of population protection, exposure to natural radiations, general system of authorizations and statements, protection of persons exposed to ionizing radiations for medical purpose, situations of radiological emergency and long exposure to ionizing radiations, penal dispositions, application of the Public Health code and application of the Labour code. Chronological contents by date of publication is given. (N.C.)

  9. Can-rupture detection in gas-cooled nuclear reactors; La detection des ruptures de gaine dans les piles nucleaires refroidies par gaz

    Energy Technology Data Exchange (ETDEWEB)

    Roguin, A. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-07-01

    Can-rupture detection (DRG) is one important aspect of pile safety, more particularly so in the case of gas-cooled reactors. A rapid and sure detection constitutes also an improvement as far as the efficiency of electricity-producing nuclear power stations are concerned. Among the numerous can-rupture detection methods, that based on the measurement of the concentration of short-lived fission gases in the heat-carrying fluid has proved to be the most sensitive and the most rapid. A systematic study of detectors based on the electrostatic collection of the daughter products of fission gases has been undertaken with a view to equip the reactors EL 2, G 3, EDF 1, EDF 2 and EDF 3, the gas loops of PEGASE and EL 4. The different parameters are studied in detail in order to obtain a maximum sensitivity and to make it possible to construct detection devices having the maximum operational reliability and requiring the minimum maintenance. The primary applications of these devices are examined in the case of the above-mentioned reactors. (author) [French] La Detection des Ruptures de Gaines (D. R. G.) est un aspect important de la securite des piles et plus particulierement des piles refroidies par un gaz. Une detection rapide et sure constitue aussi un element d'amelioration du rendement des centrales nucleaires productrices d'energie electrique. Parmi les nombreuses methodes de detection des ruptures de gaines, la mesure de la concentration dans le fluide caloporteur des gaz de fission a vie courte s'est revelee comme la plus sensible et la plus rapide. Une etude systematique des detecteurs a collection electrostatique des descendants des gaz de fission a ete entreprise en vue d'equiper les piles EL 2, G 3, EDF 1, EDF 2 et EDF 3, les boucles a gaz de la pile Pegase et la pile EL 4. Les divers parametres sont etudies en detail pour obtenir une sensibilite maximum et permettre la realisation de dispositifs de detection ayant le maximum de securite de

  10. Can-rupture detection in gas-cooled nuclear reactors; La detection des ruptures de gaine dans les piles nucleaires refroidies par gaz

    Energy Technology Data Exchange (ETDEWEB)

    Roguin, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-07-01

    Can-rupture detection (DRG) is one important aspect of pile safety, more particularly so in the case of gas-cooled reactors. A rapid and sure detection constitutes also an improvement as far as the efficiency of electricity-producing nuclear power stations are concerned. Among the numerous can-rupture detection methods, that based on the measurement of the concentration of short-lived fission gases in the heat-carrying fluid has proved to be the most sensitive and the most rapid. A systematic study of detectors based on the electrostatic collection of the daughter products of fission gases has been undertaken with a view to equip the reactors EL 2, G 3, EDF 1, EDF 2 and EDF 3, the gas loops of PEGASE and EL 4. The different parameters are studied in detail in order to obtain a maximum sensitivity and to make it possible to construct detection devices having the maximum operational reliability and requiring the minimum maintenance. The primary applications of these devices are examined in the case of the above-mentioned reactors. (author) [French] La Detection des Ruptures de Gaines (D. R. G.) est un aspect important de la securite des piles et plus particulierement des piles refroidies par un gaz. Une detection rapide et sure constitue aussi un element d'amelioration du rendement des centrales nucleaires productrices d'energie electrique. Parmi les nombreuses methodes de detection des ruptures de gaines, la mesure de la concentration dans le fluide caloporteur des gaz de fission a vie courte s'est revelee comme la plus sensible et la plus rapide. Une etude systematique des detecteurs a collection electrostatique des descendants des gaz de fission a ete entreprise en vue d'equiper les piles EL 2, G 3, EDF 1, EDF 2 et EDF 3, les boucles a gaz de la pile Pegase et la pile EL 4. Les divers parametres sont etudies en detail pour obtenir une sensibilite maximum et permettre la realisation de dispositifs de detection ayant le maximum de securite de fonctionnement et le

  11. Radiation dose reduction in digital plain radiography of the knee after total knee arthroplasty; Dosisreduktion in der digitalen Radiografie des Kniegelenkes nach endoprothetischem Gelenkersatz

    Energy Technology Data Exchange (ETDEWEB)

    Kloth, J.K.; Kauczor, H.U.; Weber, M.A. [University Hospital Heidelberg (Germany). Clinic for Diagnostic and Interventional Radiology; Tanner, M.; Ewerbeck, V. [University Hospital Heidelberg (Germany). Center of Orthopedics, Trauma and Spinal Cord Injury; Stiller, W. [German Cancer Research Center (DKFZ), Radiology (E010), Heidelberg (Germany); Burkholder, I. [Univ. of Applied Sciences of the Saarland, Dept. of Nursing and Health, Saarbruecken (Germany)

    2015-08-15

    To reduce radiation exposure of frequently performed radiographs of the knee in follow-up of total-knee arthroplasty ensuring accurate assessment by using objective quality control criteria. In this prospective randomized study 278 radiographs of the knee in follow-up of total-knee arthroplasty were performed with standard and 37 % reduced radiation dose. The evaluation of the plain-radiographs was conducted using the following criteria: bone-implant interface, implant-surface character, implant-implant discrimination and periarticular heterotopic ossification. Two radiologists evaluated these criteria using a score ranging from 1 (definitely assessable) to 4 (not assessable). If a single criterion had been evaluated with a score ≥ 3 or more than 2 criteria with ≥ 2 points, the radiograph was score das ''not assessable''. The study was designed as non-inferiority-trial. 100 % of examined radiographs were scored as assessable, hence no statistical inferiority between the examinations with standard and reduced dose could be observed. Singular assessment of the defined criteria was likewise dose-independent. Plain-radiography of the knee following total-knee arthroplasty can be performed with 63 % of standard dose without loss of diagnostic validity.

  12. Normal tissue tolerance to external beam radiation therapy: Spinal cord; Tolerance a l'irradiation des tissus sains: moelle epiniere

    Energy Technology Data Exchange (ETDEWEB)

    Habrand, J.L. [Departement de radiotherapie, institut Gustave-Roussy, 94 - Villejuif (France); Centre de protontherapie, institut Curie, 91 - Orsay (France); Drouet, F. [Departement de radiotherapie, centre Rene-Gauducheau, 44 - Nantes (France)

    2010-07-15

    Radiation myelopathy is one of the most dreadful complications of radiation therapy. Despite multiple animal experiments and human autopsic series, its pathogenesis remains largely unknown. In most instances, the classical aspect of myelomalacia combines glial and vascular injuries in various sequences. Recent studies point out the role of oligo-dendrocytes and their precursors, as well as of intercellular mediators (cytokines and stress molecules). The clinical presentation comprises a spectrum of non specific neurological symptoms whose evolution is sometimes regressive but more commonly progressive and life-threatening. Usually, it occurs following a latent period of six months to two years after irradiation of the cervical, thoracic or upper lumbar spine to a dose in excess of 50 Gy, conventionally fractionated. Nonetheless, these typical features can be altered by extrinsic factors, such as hypo fractionation/acceleration of the dose, multiple surgical procedures, chemotherapy especially mega therapy, or neurotoxic drugs. Conversely, hyperfractionated regimens that take into account protracted half-time repair of sublethal damages to the CNS, as well as sophisticated estimates of the dose to the cord and QA programs during the treatment course minimize such risks. (authors)

  13. Organisation of maintenance of health semi-portable detectors. IPAB-CFA-CABP control bench; Organisation de la maintenance des detecteurs semi-portatifs de sante. Banc de controle des IPAB-CFA-CABP

    Energy Technology Data Exchange (ETDEWEB)

    De Choudens, H.; Rage, P. [Commissariat a l' energie atomique et aux energies alternatives - CEA, Centre d' Etudes Nucleaires de Grenoble (France)

    1963-07-01

    As the number of electronic semi-portable health measurement devices is (was) increasing, it appears (appeared) important to organise their maintenance. In this report, the authors describe the implemented organisation. They indicate how a device is identified, which are the performed tests, and discuss results which have been obtained during the first year of implementation of this maintenance organisation. Then, they present the control bench, its operation (supply, measurement circuits), its use (control process for different devices, performed measurements and controls)

  14. Cross section and di-fermionic asymmetry measurements by ALEPH detector at LEP2 - Interpretations beyond Standard Model; Mesures des sections efficaces et des asymetries difermioniques avec le detecteur Aleph a LEP2 - Interpretations au-dela du Modele Standard

    Energy Technology Data Exchange (ETDEWEB)

    Merle, Elsa [Laboratoire d' Annecy-le-vieux de physique des particules, Grenoble-1 Univ., 74 Annecy (France)

    1999-04-22

    The present work is based on the selection of e{sup -}e{sup +} {yields} f f-bar events taken with the ALEPH detector from 1995 to 1998, for an integrated luminosity of 500 pb{sup -}. We first present the selection of dimuon, di-tau and di-electron events that we have been developed for this study. The hadronic selection used in ALEPH is also detailed in a devoted part. In each case, the estimation of systematic uncertainties is described. They are of the same order of magnitude as the statistical errors, ranging between 0.6% (di-electron) and 3.5% (dimuon). From these selections we derive the di-fermionic cross-sections as well as the asymmetries computed for the di-lepton channels. Measurements are found to be in reasonable agreement with the Standard Model expectations. Cross-sections and asymmetries are sensitive to the presence of possible new physics. In this document we use the context of the 4-fermion contact interactions to set limits on the energy scale of new physics. Such limits are found to range between 7 and 15 GeV depending on the modelling used. We also put lower limits on the mass of leptoquarks, 590 GeV/c{sup 2} for vector leptoquarks and 71 GeV/c{sup 2} for scalar leptoquarks. Eventually we also present the limits derived in the context of R-parity violated supersymmetry, putting constraint on the s-neutrino mass. Our study excludes such particles below a few hundred GeV/c{sup 2} mass for high values of their Yukawa coupling assumptions.

  15. Study of intense pulse irradiation effects on silicon targets considered as ground matter for optical detectors; Etude des effets d`irradiations pulsees intenses sur des cibles de silicium considere en tant que materiau de base pour detecteurs optiques

    Energy Technology Data Exchange (ETDEWEB)

    Muller, O

    1994-12-01

    This study aim was centered on morphological and structural alterations induced by laser irradiation on silicon targets considered as ground matter for optical detectors. First we recalled the main high light intensity effects on the condensed matter. Then we presented the experimental aspects. The experimental studies were achieved on two sample types: SiO{sub 2}/Si and Si. Two topics were studied: the defect chronology according to wavelength and pulse length, and the crystalline quality as well as the structure defects of irradiated zones by Raman spectroscopy. Finally, irradiation of Si targets by intense pulsed beams may lead to material fusion. This phenomenon is particularly easy when the material is absorbent, when the pulse is short and when the material is superficially oxidized. (MML). 204 refs., 93 figs., 21 tabs., 1 appendix.

  16. Gestion des risques

    CERN Document Server

    Louisot, Jean-Paul

    2009-01-01

    Depuis le début du lie siècle, la gestion des risques connaît une véritable révolution culturelle. Jusqu'alors fonction technique, centrée autour de l'achat de couverture d'assurances, elle est devenue une discipline managériale et transversale : une valise d'instruments que chaque manager doit connaître et appliquer quels que soient son domaine de compétence et ses missions au sein de l'organisation. En effet, la gestion des risques est une culture qui doit être assimilée par chacun des acteurs. C'est précisément l'ambition des 101 questions rassemblées dans cet ouvrage : apporter à chaque manager d'entreprise, de collectivité, d'établissement de santé..., des réponses claires au " pourquoi " et au " comment " : Comment identifier les risques ? Comment analyser les risques ? Quels sont les objectifs de la gestion des risques ? Une carte des risques pour quoi faire ? Pourquoi faut-il financer les risques ? Les entreprises ont-elles des responsabilités pénales ? En quoi consiste la gestion...

  17. Measurement of the C / H ratio using neutrons; Mesure du rapport C / H au moyen des neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Martinelli, P [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires; Ricci, H [Universite de Lima (Peru)

    1960-07-01

    A probe made up of a Ra ({alpha}, n) Be neutron source and a proportional counter filled with boron trifluoride has been used to measure the C/H ratio in hydrocarbons. The intensity of the thermal neutron flux in the neighbourhood of the detector increases with the concentration of the hydrocarbon hydrogen surrounding it. By measuring the density it is possible to deduce the C/H ratio. It is thus possible to evaluate the C/H ratio with a precision equal to that given by the {beta}-ray transmission method. The errors arising from the chemical nature of the hydrocarbon can be reduced to a minimum. This method has the advantage of allowing the measurement of the C/H ratio of hydrocarbons contained in recipients or thick steel tubing by means an independent portable apparatus. (author) [French] Une sonde constituee d'une source de neutrons Ra ({alpha}, n) Be et d'un compteur proportionnel a remplissage de trifluorure de bore a ete utilisee pour mesurer le rapport C/H dans les hydrocarbures. Le flux des neutrons thermiques au voisinage du detecteur est d'autant plus intense que la concentration en hydrogene de l'hydrocarbure qui entoure la sonde est plus elevee. Une mesure de densite permet d'en deduire le rapport C/H. On peut ainsi evaluer le rapport C/H avec une precision aussi bonne que celle que l'on obtient par transmission de rayons {beta}. Les erreurs provenant de la nature chimique de l'hydrocarbure peuvent etre minimisees. Cette methode presente l'avantage de permettre la mesure du rapport C/H d'hydrocarbures contenus dans des recipients ou des canalisations epaisses en acier a l'aide d'un appareil exterieur transportable. (auteur)

  18. The Prompt Gamma-Ray, Prompt Electron and Prompt X-Ray Spectra Associated with Fission Fragments of Specific Mass; Spectres de Rayons Gamma Instantanes, d'Electrons Instantanes et de Rayons X Instantanes Associes a des Fragments de Fission de Masse Donnee; 041c 0413 041d 041e 0414 ; Espectros de Rayos Gamma. Electrones y Rayos X Inmediatos, Vinculados a Fragmentos de Fision de Masa Determinada

    Energy Technology Data Exchange (ETDEWEB)

    Bowman, H. R.; Thompson, S. G.; Watson, R. L.; Kapoor, S. S.; Rasmussen, J. O. [Lawrence Radiation Laboratory, University of California, Berkeley, CA (United States)

    1965-07-15

    Well-defined prompt gamma-rays, prompt-conversion elections and prompt K-X-rays have been observed in coincidence with moving fission fragments of Cf{sup 252}. In a few cases, the masses and charges of the nuclei emitting the gamma-rays and conversion electrons have been identified. The gamma-ray, prompt-electron and prompt X-ray energies as well as the two fission fragments energies were measured with high-resolution solid-state detectors. The masses of the fragments were deduced from their energies, and the nuclear charges were determined by measuring the K-X - ray energies associated with different masses. The magnitude and sign of the Doppler shift in gamma-ray energy allowed assignment of the gamma-ray lines to single members of fragment pairs. The Doppler shift also provides an independent measure of the fragment velocity and hence the fragment mass after neutron emission. The results of the X-ray measurements are consistent with the view that the majority of the prompt X-rays emitted during the spontaneous fission of Cf{sup 252} are the result of internal conversion during the de-excitation of low-energy collective states of the primary fission fragments. Apart from the specific results discussed above, the most important consequence of these experiments has been the demonstration that it is possible to study the properties of individual fission fragments, as identified by their characteristic radiations, rather than studying the properties of an average fission fragment with an average mass and charge. The consequences of this advance in the technique of studying fission fragments ate being explored. (author) [French] Des rayons gamma instantanes, des electrons de conversions instantanes et des rayons X K instantanes bien definis ont ete observes en coincidences avec des fragments de fission de {sup 252}Cf en mouvement. Dans un petit nombre de cas' Les masses, et charges des noyaux emettant les rayons gamma et les electrons de conversion ont ete identifiees

  19. La gouvernance des risques naturels et la problematique des ...

    African Journals Online (AJOL)

    Depuis quelques années, la gouvernance des risques naturels dus aux inondations remet en cause les processus de mise en oeuvre des politiques urbaines et la qualité de la structure des aménagements dans les grandes villes du Golfe de Guinée. La perception de la gouvernance et l'application des politiques de ...

  20. Detection and location of can rupture in reactors cooled by a flow of water; Detection et localisation des ruptures de gaines sur les reacteurs refroidis par circulation d'eau

    Energy Technology Data Exchange (ETDEWEB)

    Le Meur, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1968-07-01

    This report brings together the principal methods of fission-product detection used for water reactors. The position, type and method of adjustment is given for each detector. The methods for localizing the defective elements are explained, in particular those using water sampling or decreases in the flux. A few installations are briefly described. They correspond to particular types of reactors using boiling, pressurized or cold water. Amongst the many methods used, it can be noted that when the fuel is resistant, the installations are fairly compact. In nuclear super-heated reactors on the other hand, the study of fuel behaviour calls for larger installations. An identification of defective elements exists when the reactor structure allows it. If this is not possible, a localization in a group of elements is obtained by a flux depression. (author) [French] Ce rapport rassemble les principales methodes de detection de produits de fission utilisees pour des reacteurs a eau. On indique pour les detecteurs leurs emplacements, leurs types, leurs reglages. On explique quelles sont les methodes de localisation des elements defectueux, en particulier celles utilisant des prelevements d'eau ou des depressions de flux. Quelques installations sont decrites sommairement. Elles correspondent a des types particuliers de reacteurs a eau bouillante, pressurisee ou froide. Parmi les nombreuses methodes utilisees, on constate que les installations sont peu importantes, lorsque le combustible est resistant. Par contre dans les reacteurs a surchauffe nucleaire l'etude du comportement du combustible necessite des installations plus importantes. Une identification d'elements defectueux existe lorsque la structure du reacteur le permet. A defaut une localisation dans un groupe d'elements est obtenue par depression de flux. (auteur)

  1. A gas dynamics scheme for a two moments model of radiative transfer; Un schema de type dynamique des gaz pour un modele a deux moments en transfert radiatif

    Energy Technology Data Exchange (ETDEWEB)

    Buet, Ch.; Despres, B

    2007-07-01

    We address the discretization of the Levermore's two moments and entropy model of the radiative transfer equation. We present a new approach for the discretization of this model: first we rewrite the moment equations as a Compressible Gas Dynamics equation by introducing an additional quantity that plays the role of a density. After that we discretize using a Lagrange-projection scheme. The Lagrange-projection scheme permits us to incorporate the source terms in the fluxes of an acoustic solver in the Lagrange step, using the well-known piecewise steady approximation and thus to capture correctly the diffusion regime. Moreover we show that the discretization is entropic and preserve the flux-limited property of the moment model. Numerical examples illustrate the feasibility of our approach. (authors)

  2. Radiating residues from production and consumption. On the political economy of radioactive waste; Strahlende Hinterlassenschaften aus Produktion und Konsumtion. Zur Politischen Oekonomie des Atommuells

    Energy Technology Data Exchange (ETDEWEB)

    Brunnengraeber, Achim; Mez, Lutz

    2014-09-15

    The contribution on radiating residues from production and consumption discusses the following issues: (1) Endless production of waste - not only from NPP operation but in every phase of the fuel cycle starting with uranium mining. (2) Paradoxes and polarizations: the discrepancy between the continuous production of nuclear waste and the unsolved question of final disposal is accompanying the whole nuclear energy age: the experiences show that neither technical nor geological barriers can guarantee the safe retention of fission products from the environment. (3) Private goods, public bads: the NPP owner tend to reach highest profit but want to shift the cost for waste disposal to the public; the situation in Germany is discussed in detail. (4) Conclusions and the final repository governance: the ongoing search for a final repository site in Germany demonstrates the development of the waste problem to a wicked problem.

  3. Normal tissue tolerance to external beam radiation therapy: Peripheral nerves; Dose de tolerance a l'irradiation des tissus sains: les nerfs peripheriques

    Energy Technology Data Exchange (ETDEWEB)

    Henriques de Figueiredo, B.; Dejean, C.; Sargos, P.; Kantor, G. [Departement de radiotherapie, institut Bergonie, centre regional de lutte contre le cancer, 33 - Bordeaux (France); Huchet, A.; Mamou, N. [Service d' oncologie medicale et de radiotherapie, CHU Saint-Andre, 33 - Bordeaux (France); Loiseau, H. [Service de neurochirurgie, CHU Pellegrin, 33 - Bordeaux (France)

    2010-07-15

    Plexopathies and peripheral neuropathies appear progressively and with several years delay after radiotherapy. These lesions are observed principally after three clinical situations: supraclavicular and axillar irradiations for breast cancer, pelvic irradiations for various pathologies and limb irradiations for soft tissue sarcomas. Peripheral nerves and plexus (brachial and lumbosacral) are described as serial structures and are supposed to receive less than a given maximum dose linked to the occurrence of late injury. Literature data, mostly ancient, define the maximum tolerable dose to a threshold of 60 Gy and highlight also a great influence of fractionation and high fraction doses. For peripheral nerves, most frequent late effects are pain with significant differences of occurrence between 50 and 60 Gy. At last, associated pathologies (diabetes, vascular pathology, neuropathy) and associated treatments have probably to be taken into account as additional factors, which may increase the risk of these late radiation complications. (authors)

  4. Normal tissue tolerance to external beam radiation therapy: Testicles; Dose de tolerance a l'irradiation des tissus sain: les testicules

    Energy Technology Data Exchange (ETDEWEB)

    Champetier, C.; Gross, E.; Zaccariotto, A.; Duberge, T.; Guerder, C. [Service de radiotherapie, hopital de la Timone, 13 - Marseille (France); Pointreau, Y. [Pole Henry-S.-Kaplan, CHU Bretonneau, 37 - Tours (France); Ortholan, C. [Centre Antoine-Lacassagne, 06 - Nice (France); Chauvet, B. [Institut Sainte-Catherine, 84 - Avignon (France)

    2010-07-15

    Although there is very little evidence for direct irradiation of the testes, they may receive significant doses, especially in the treatment of pelvic tumors in adults and in pediatrics. The exocrine function of the testis seems to be more sensitive to radiotherapy. There is a risk of sterility, even after low doses of radiation. In the adult or the child who has reached puberty, we should propose a self-preservation of semen prior to radiotherapy. In pre-pubescent children, the problem is more delicate. In all cases, it is necessary to limit the dose to the testicles without affecting the coverage of tumour volume. Patients and/or their care-givers should be systematically informed of the risk of infertility related to irradiation. (authors)

  5. Radioisotopes and Radiation in Animal and Plant Insect Pest Control; Emploi des radioisotopes et des rayonnements dans la lutte contre les insectes nuisibles aux plantes et aux animaux; Ispol'zovanie radioizotopov i radiashchi v bor'be s nasekomymi-vreditelyami rastenij i zhivotnykh; Utilizacion de los radioisotopos y de las radiaciones en la lucha contra los insectos nocivos para las plantas y los animales

    Energy Technology Data Exchange (ETDEWEB)

    Andreev, S. V.; Martens, B. K.; Samojlova, V. A.; Molchanova, Z. I. [Vsesoyuznyj Institut Zashchity Rastenij, Leningrad, SSSR (Russian Federation)

    1963-09-15

    degrees of stability when subjected to the action of herbicides. Pesticides containing trace quantities of isotopes with short half-lives can be used as a means of judging the merits of various spraying systems for treating seeds and agricultural crops with pesticides; this method also provides information about the optimum doses. Experiments have shown that ionizing radiations can be used to increase the virulence of insect nosophytes (Beauveria vassiana Unill.) and thus improve the efficiency of microbiological insect-pest-control methods. The sterilizing and lethal effects of ionizing radiations are also useful in combatting insect pests. Gamma-ray experiments have made it possible to establish sterilizing doses for a number of insect pests which attack crops and stored products (Calandra granaria L., Acanthoscelides obtectus Say, Pectinophora malvella Hb., Leptinotarsa decemlineota Say, Chloridea obsoleta F.). The data obtained in these investigations will be used to develop and improve the methods of insect-pest control used in agriculture. (author) [French] Le probleme de la lutte contre les parasites des cultures presente une grande importance pour l'economie nationale. Il importe, pour le resoudre, de tirer parti des realisations scientifiques les plus recentes. Pour rationaliser les methodes actuelles de lutte contre les insectes nuisibles et accroitre l'efficacite de ces methodes, on a fait appel aux radioisotopes et aux rayonnements. Grace a remploi des radioisotopes et des rayonnements, il est possible de rationaliser dans une large mesure les methodes utilisees et d'augmenter leur efficacite. A cet effet, il est indispensable d'etudier a fond les problemes d'ecologie, de toxicologie, etc. Dans le domaine de l'ecologie, la methode du radiomarquage des insectes est particulierement prometteuse. L'emploi de radioisotopes pour le marquage des insectes ravageurs des cereales (Eurygaster integriceps Put. et Hadena sordida Skh.) et de leurs parasites (Meniscus

  6. Amorphous silicon cells for the measurement of photosynthetically active radiation; Utilisation des cellules au silicium amorphe pour la mesure du rayonnement photosynthétiquement actif (400-700 nm)

    Energy Technology Data Exchange (ETDEWEB)

    Chartier, M. [Institut National de la Recherche Agronomique, Thiverval-Grignon (France); Bonchretien, P.; Allirand, J. M.; Gosse, G.

    1989-07-01

    Numerical simulation and experimental measurements from amorphous silicon cells in comparison with these now used in ecophysiology illustrate the interest of amorphous silicon cells for the measurement of PAR incident, reflected, and transmitted below the canopy [French] La simulation et la confrontation expérimentale ces réponses des cellules au silicium amorphe par rapport à celles des capteurs existants montrent l’intérêt des cellules au silicium amorphe pour la mesure du rayonnement PAR (exprimé en densité de flux de photons) incident, réfléchi et transmis sous un couvert végétal.

  7. Contribution to the study of the leukemia potential of radiation used in radio-diagnostic in children: statistical study of the main radiological examinations according to age and sex (1963); Contribution a l'etude du pouvoir leukemogene des radiations utilisees en radiodiagnostic chez l'enfant: etude statistique des principaux examens radiologiques suivant l'age et le sexe

    Energy Technology Data Exchange (ETDEWEB)

    Larcher, B [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1963-06-15

    With a view to discovering whether low irradiation doses are liable to increase the incidence of leukemia or cancer amongst people exposed to this risk, an enquiry, has been undertaken into the distribution according to age and to sex of 13,596 important radiological examinations carried out in radio-pediatric departments from 1953 to 1961, a population structure study essential for choosing the group studied and the comparison group. This survey will be used as the basis for the constitution of a population whose pathology will be examined with great care. The main conclusion resulting from this enquiry is that the frequency of digestive and urinary examinations is very high in babies of under one year old and higher in boys than in girls. (author) [French] Dans le but de determiner si les faibles doses d'irradiations sont susceptibles d'augmenter le taux de leucemies ou de cancer dans les populations exposees a ce risque, une enquete a ete faite sur la repartition par age et par sexe de 13596 examens radiologiques importants effectues dans des services de radiopediatrie de 1953 a 1961, elude de la structure de la population necessaire pour choisir le groupe etudie et le groupe temoin. Ce releve sert de base a la constitution d'une population dont la pathologie sera recherchee avec soin. De cette enquete, il ressort essentiellement que la frequence des examens digestifs et urinaires est tres elevee chez les nourrissons ages de moins d'un an, et plus elevee chez les garcons que chez les filles. (auteur)

  8. Contribution to the study of the leukemia potential of radiation used in radio-diagnostic in children: statistical study of the main radiological examinations according to age and sex (1963); Contribution a l'etude du pouvoir leukemogene des radiations utilisees en radiodiagnostic chez l'enfant: etude statistique des principaux examens radiologiques suivant l'age et le sexe

    Energy Technology Data Exchange (ETDEWEB)

    Larcher, B. [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1963-06-15

    With a view to discovering whether low irradiation doses are liable to increase the incidence of leukemia or cancer amongst people exposed to this risk, an enquiry, has been undertaken into the distribution according to age and to sex of 13,596 important radiological examinations carried out in radio-pediatric departments from 1953 to 1961, a population structure study essential for choosing the group studied and the comparison group. This survey will be used as the basis for the constitution of a population whose pathology will be examined with great care. The main conclusion resulting from this enquiry is that the frequency of digestive and urinary examinations is very high in babies of under one year old and higher in boys than in girls. (author) [French] Dans le but de determiner si les faibles doses d'irradiations sont susceptibles d'augmenter le taux de leucemies ou de cancer dans les populations exposees a ce risque, une enquete a ete faite sur la repartition par age et par sexe de 13596 examens radiologiques importants effectues dans des services de radiopediatrie de 1953 a 1961, elude de la structure de la population necessaire pour choisir le groupe etudie et le groupe temoin. Ce releve sert de base a la constitution d'une population dont la pathologie sera recherchee avec soin. De cette enquete, il ressort essentiellement que la frequence des examens digestifs et urinaires est tres elevee chez les nourrissons ages de moins d'un an, et plus elevee chez les garcons que chez les filles. (auteur)

  9. Determination of the thermal radiation effect on an optical strontium lattice clock; Bestimmung des Einflusses thermischer Strahlung auf eine optische Strontium-Gitteruhr

    Energy Technology Data Exchange (ETDEWEB)

    Middelmann, Thomas

    2013-05-31

    Optical clocks have the potential to be 100 times more accurate than current best cesium atomic clocks within a fraction of the averaging time. This corresponds to a fractional uncertainty of the clock frequency on the level of 10{sup -18} and requires highaccuracy knowledge of systematic frequency shifts, such that they can be avoided or corrected for. In strontium optical lattice clocks an ensemble of ultracold strontium atoms is confined in an optical lattice, to allow for spectroscopy of the reference transition 5s{sup 2} {sup 1}S{sub 0}-5s5p {sup 3}P{sub 0} in the Lamb-Dicke regime. The by far largest systematic frequency shift of the strontium clock transition is caused by its high sensitivity to blackbody radiation (BBR). The knowledge of the resulting frequency shift limited the achievable clock uncertainty to about 1 x 10{sup -16}. In this thesis for the first time an experimental approach was followed, to determine the sensitivity of the strontium clock transition to blackbody radiation. At an environmental temperature of 300 K the resulting frequency shift corresponds to 2.277 8(23) Hz. The achieved uncertainty contributes with 5 x 10{sup -18} to the fractional systematic uncertainty of the clock frequency. The determination is based on a precision measurement of the difference of static polarizabilities of the two clock states {Delta}{alpha}{sub dc} = {alpha}(5s5p {sup 3}P{sub 0})-{alpha}(5s{sup 2} {sup 1}S{sub 0}) = 4.078 73(11) x 10{sup -39} Cm{sup 2} /V. For this the de Stark shift of the clock transition has been measured in the accurately known electric field of a precision plate capacitor, which has been developed in this work. The attained static polarizability difference {Delta}{alpha}{sub dc} corresponds to the first term of a power series of the sensitivity to BBR. Higher orders are accumulated as dynamic part of the BBR shift. Which has been modelled using {Delta}{alpha}{sub dc} and experimental data for other atomic properties. To

  10. Part 1: The detection of criticality accidents in the Commissariat a l'Energie Atomique. Part 2: The Burst Slug Detection; 1. partie: la detection des accidents de criticite au Commissariat a l'Energie Atomique. 2. partie.: la detection des ruptures de gaines

    Energy Technology Data Exchange (ETDEWEB)

    Debrie, G; Lavie, J; Planque, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    accidents survenus et du role attendu d'un detecteur, le choix s'est porte sur un dispositif a integration de dose en ce qui concerne la sonde de detection proprement dite et sur un principe de la coincidence de plusieurs informations pour le declenchement de l'alarme. Les caracteristiques physiques et electroniques minimales d'un materiel garantissant un fonctionnement sur et limitant au maximum le risque de fausses alarmes etablies a la demande de la Sous-Commission des Masses Critiques sont exposees avec quelques details. Les materiels realises sur ces bases au Commissariat a l'Energie Atomique ont fait l'objet d'essais systematiques dans des conditions reelles d'excursion nucleaire aupres du Health Physics Research Reactor du Laboratoire National d'Oak Ridge. Ces essais ont permis de retenir deux principes de sondes de detection qui seront decrites: sonde a photomultiplicateur fonctionnant en courant et sonde a semi-conducteur. Enfin les auteurs presentent un exemple concret de realisation d'un equipement complet de detecteur des accidents de criticite dans une installation traitant de la matiere fissile. B - L'evolution des installations de detection des ruptures de gaines (DRG) dans les piles francaises. La majorite des efforts dans le domaine de la detection des ruptures de gaine a porte ces dernieres annees sur les grands reacteurs refroidis par gaz, ou le probleme des ruptures de gaine est lie a la rentabilite de la centrale. Une adaptation des techniques mises au point a cette occasion permet ensuite de resoudre facilement les problemes de detection pour les autres types de reacteurs. L'essentiel de l'evolution des diverses installations realisees ou en cours de realisation s'est traduit par une progression constante vers une plus grande automaticite et par l'utilisation de detecteurs fonctionnant sous des temperatures et des pressions de plus en plus elevees. Apres la pile G 3 qui possedait deja une installation tres automatique, on a vu apparaitre pour les piles

  11. Photonique des Morphos

    CERN Document Server

    Berthier, Serge

    2010-01-01

    La photonique est déjà présente dans notre vie quotidienne, et on attend maintenant que la manipulation des photons permette aussi le traitement logique des informations. Cependant, l’élément de base qui permet cette manipulation de la lumière, le cristal photonique, est d’une réalisation complexe et mal contrôlée. Dans la course à la maîtrise de la lumière, les structures photoniques naturelles ont beaucoup à nous apprendre. C’est ce que nous montre Serge Berthier qui étudie dans ce livre la structure des écailles des Morphos. Tenant compte de l’essor récent des approches biomimétiques, il présente de manière détaillée plus de dix-huit techniques expérimentales utilisées pour ses analyses, ainsi que les diverses approches théoriques développées pour la modélisation de structures multi-échelles complexes. Première étude quasi-exhaustive des structures fines d’un genre et des propriétés optiques ainsi que colorimétriques générées, ce livre fournit aux entomologiste...

  12. Droit des organisations internationales

    CERN Document Server

    Sorel, Jean-Marc; Ndior, Valère

    2013-01-01

    Cet ouvrage collectif offre aux enseignants et chercheurs en droit international, aux praticiens et aux étudiants, une analyse actualisée du droit des organisations internationales. Il dresse en cinq parties un tableau, illustré par des exemples variés, des problématiques que soulève le phénomène polymorphe d institutionnalisation de la société internationale. La première partie est consacrée au phénomène des « organisations internationales », sous l angle à la fois de l institutionnalisation progressive des relations internationales et de la difficulté à cerner une catégorie unifiée. La deuxième partie rend compte de la création, de la disparition et des mutations des organisations internationales, ici envisagées comme systèmes institutionnels et ordres juridiques dérivés. La troisième partie analyse l autonomie que l acquisition de la personnalité juridique et de privilèges et immunités, un organe administratif intégré, un personnel ou un budget propres confèrent aux organi...

  13. Normal tissue tolerance to external beam radiation therapy: Larynx and pharynx; Dose de tolerance a l'irradiation des tissus sains: larynx et pharynx

    Energy Technology Data Exchange (ETDEWEB)

    Debelleix, C. [Service de radiotherapie, centre hospitalier Dax-Cote d' Argent, 40 - Dax (France); Service de radiotherapie, hopital Saint-Andre, CHU de Bordeaux, 33 - Bordeaux (France); Pointreau, Y.; Calais, G. [Service de radiotherapie, centre regional universitaire de cancerologie Henry-S.-Kaplan, hopital Bretonneau, CHU de Tours, 37 - Tours (France); Universite Francois-Rabelais, 37 - Tours (France); Pointreau, Y. [CNRS, UMR 6239 Genetique, immunotherapie, chimie et cancer, 37 - Tours (France); Laboratoire de pharmacologie-toxicologie, CHRU de Tours, 37 - Tours (France); Lafond, C.; Denis, F. [Centre Jean-Bernard, clinique Victor-Hugo, 72 - Le Mans (France); Bourhis, J.H. [Institut Gustave-Roussy, 94 - Villejuif (France)

    2010-07-15

    For head and neck cancers, the radiation dose usually needed to sterilize a macroscopic tumour is at least 70 Gy in conventional fractionation. In the larynx, this dose level enables optimal tumour control while exposing the patient to a limited risk of severe complications. For oropharynx and nasopharynx tumors, it is sometimes possible to limit the dose received by the larynx according to the extent of the primary lesion. Thus, if the tumour constraints permit, the maximum dose to the larynx must be less than 63 to 66 Gy. To reduce the risk of laryngeal edema, it is recommended if possible to limit the mean non-involved larynx dose to 40 to 45 Gy. In the pharynx, literature's data suggested to minimize the volume of the pharyngeal constrictor muscles receiving a dose greater than or equal to 60 Gy. Limiting the volume receiving a dose greater than or equal to 50 Gy reduces the risk of dysphagia. These dose constraints should be tailored to each patient taking into account the extent of the initial primary lesion, the possible addition of chemotherapy or a modified fractionation radiotherapy. (authors)

  14. Intensity-modulated radiation therapy for anal carcinoma; Radiotherapie conformationnelle avec modulation d'intensite des cancers de l'anus

    Energy Technology Data Exchange (ETDEWEB)

    Peiffert, D.; Moreau-Claeys, M.V.; Tournier-Rangeard, L.; Huger, S.; Marchesi, V. [Departement de radiotherapie, centre Alexis-Vautrin, 6, avenue de Bourgogne, 54511 Vandoeuvre-les-Nancy cedex (France)

    2011-10-15

    Anal canal carcinoma are highly curable by irradiation, combined with chemotherapy in locally advanced disease, with preservation of sphincter function. The clinical target volume for the nodes is extended, often including the inguinal nodes, which is not usual for other pelvic tumours. Acute and late effects are correlated with the volume and dose delivered to organs at risk, i. e. small bowel, bladder and increased by concomitant chemotherapy. Intensity modulated irradiation (IMRT) makes it possible to optimize the dose distribution in this 'complex U shaped' volume, while maintaining the dose distribution for the target volumes. The conversion from conformal irradiation to IMRT necessitates good knowledge of the definition and skills to delineate target volumes and organs at risk, including new volumes needed to optimize the dose distribution. Dosimetric and clinical benefits of IMRT are described, based on early descriptions and evidence-based publication. The growing development of IMRT in anal canal radiotherapy must be encouraged, and long-term benefits should be soon published. Radiation oncologists should precisely learn IMRT recommendations before starting the technique, and evaluate its early and late results for adverse effects, but also for long-term tumour control. (authors)

  15. Results and toxicity of the treatment of anal canal carcinoma by radiation therapy or chemoradiotherapy. Therapieergebniss, Frueh- und Spaettoxizitaet der Behandlung des Analkanalkarzinoms durch Strahlentherapie oder Chemoradiotherapie

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, K.; Brockmann, W.P.; Wiegel, T.; Kruell, A.; Huebener, K.H.; Birk, S. (Universitaetskrankenhaus Eppendorf, Hamburg (Germany). Abt. fuer Strahlentherapie)

    1991-08-01

    From 1975 to 1989 114 patients with analcanal carcinoma were treated, 81 of these with radiotherapy (RT) alone and 33 with chemoradiotherapy (CRT). 80% respectively 82% of the patients were colostomy-free at the onset of therapy. RT was given to a total dose of 60 Gy in six weeks, for CRT additional simultaneous 5-fluorouracil (500 mg/m{sup 2} days 1 to 5 and 8 to 12) and mitomycin C (5 mg/m{sup 2} days 5 and 12) was administered. 67% respectively 82% of the patients had UICC stage II to IIIB disease predominantly with G2 and G3 squamous cell carcinomas. Local control after three years was 79% for the RT group vs. 82% for the CRT group. Three-year survival rate was 68% and 71%, respectively. These differences were not signficant. Only for G1-compared to G3-tumors there is a significantly higher survival rate. Acute and late damage was slightly lower for the RT treatment group (77% and 25%) compared to the CRT group (79% and 30%). In both treatment groups there was one patient needing a permanent colostomy due to radiation induced proctitis. In conclusion, RT or CRT should be the primary form of treatment in patients with anal canal carcinoma and abdominoperineal resection should only be performed in case of local recurrence or tumor persitence. The final decision about the indications for RT or CRT can only be made with the results of a prospective randomized trial. (orig.).

  16. Thermoluminescent properties of CVD diamond: applications to ionising radiation dosimetry; Proprietes thermoluminescentes du diamant CVD: applications a la dosimetrie des rayonnements ionisants

    Energy Technology Data Exchange (ETDEWEB)

    Petitfils, A

    2007-09-15

    Remarkable properties of synthetic diamond (human soft tissue equivalence, chemical stability, non-toxicity) make this material suitable for medical application as thermoluminescent dosimeter (TLD). This work highlights the interest of this material as radiotherapy TLD. In the first stage of this work, we looked after thermoluminescent (TL) and dosimetric properties of polycrystalline diamond made by Chemically Vapor Deposited (CVD) synthesis. Dosimetric characteristics are satisfactory as TLD for medical application. Luminescence thermal quenching on diamond has been investigated. This phenomenon leads to a decrease of dosimetric TL peak sensitivity when the heating rate increases. The second part of this work analyses the use of synthetic diamond as TLD in radiotherapy. Dose profiles, depth dose distributions and the cartography of an electron beam obtained with our samples are in very good agreement with results from an ionisation chamber. It is clearly shown that CVD) diamond is of interest to check beams of treatment accelerators. The use of these samples in a control of treatment with Intensity Modulated Radiation Therapy underlines good response of synthetic diamond in high dose gradient areas. These results indicate that CVD diamond is a promising material for radiotherapy dosimetry. (author)

  17. Use of alpha-radiation for the industrial measurement of surface weight; Utilisation du rayonnement alpha pour les mesures industrielles de poids superficiel; Primenenie al'fa-oblucheniya dlya promyshlennogo izmereniya vesa naruzhnogo pokrova; Empleo industrial de los rayos alfa para la medicion de pesos por unidad de superficie

    Energy Technology Data Exchange (ETDEWEB)

    Perette, J; Maugest, J [Compagnie d' Applications et Recherches Atomiques, Saint-Denis (France)

    1962-01-15

    The possibility of using alpha-radiation for industrial measurement of the surface weight of thin materials has been mentioned by several authors. The techniques have been adapted for industrial use thanks to research on new equipment which, while employing standard techniques, was specially designed for alpha-radiation. To compensate for variations in the absorbent capacity of the source-detector interval, a two-path differential method must be used. By alternate feeding of the ionization chambers, alternate amplification and detection circuits can be used without prior conversion of the ionization current. The measurement range is 6 to 55 g/m{sup 2} and measurement is accurate to 1% in conditions of perfect stability. The complete equipment used for continuous measurement on production machines is described. The technique can also be used with beta-radiation. (author) [French] Les possibilites d'emploi du rayonnement alpha pour les mesures industrielles de poids superficiel de materiaux minces ont deja ete citees par plusieurs auteurs. L'exploitation industrielle de ces techniques a pu se developper grace a l'etude de nouveaux appareils qui, bien qu'utilisant des techniques classiques, ont ete specialement concus pour l'utili sation du rayonnement alpha. L'emploi d'une methode differentielle a deux trajets est indispensable pour la compensation des variations de pouvoir absorbant de l'intervalle source-detecteur. L'alimentation en alternatif des chambres d'ionisation permet l'utilisation de circuits alternatifs d'amplification et de detection sans conversion prealable du courant d'ionisation. La gamme de mesure s'etend de 6 g a 55 g/m{sup 2} avec line precision de 1% dans des conditions de parfaite stabilite. On decrit le dispositif complet utilise pour les mesures en continu sur les machines de production. Cette technique est egalement utilisable pour les rayonnements beta. (author) [Spanish] Diversos investigadores ya han mencionado la posibilidad de emplear

  18. Santé des adolescents et des jeunes au Burkina Faso : état des ...

    African Journals Online (AJOL)

    Il s'est agi d'une étude évaluative ayant utilisé une revue documentaire associée à une interview des acteurs clés et un atelier de validation et d'identification des interventions pertinentes pour un plan stratégique national. La situation de la santé des adolescents et des jeunes est caractérisée par des grossesses précoces ...

  19. Dental Encounter System (DES)

    Data.gov (United States)

    Department of Veterans Affairs — Dental Encounter System (DES) is an automated health care application designed to capture critical data about the operations of VA Dental Services. Information on...

  20. Diethylstilbestrol (DES) and Cancer

    Science.gov (United States)

    ... DES-exposed grandchildren have? Researchers are also studying possible health effects among women and men who are the children ... for unexposed men. In addition, researchers are studying possible health effects on the grandchildren of mothers who were exposed ...

  1. Table des illustrations

    OpenAIRE

    2016-01-01

    Tableaux Dates d’inauguration des grands hôtels japonais entre 1860 et 1945… 19 Histoire, tourisme et hôtellerie en Corée depuis les années 1870… 59-60 Dates d’inauguration des grands hôtels chinois depuis 1863… 84 Les hôtels de luxe et leurs capacités d’hébergement en Corée en 2000… 103 Les flux de personnes suscités par les hôtels « super luxe » de Séoul en 2000… 105 L’activité des grands hôtels à Séoul en 1999 (en wons)… 106 Propriété et gestion des grands hôtels à Séoul en 1999…. 110 La c...

  2. Direction des Publications

    African Journals Online (AJOL)

    Synthese

    potential and surface properties of their mixtures were investigated, in an ... suppose that the electrostatic repulsive interactions between the two anion ... concentration, et de la conformation des ..... proteins and polysaccharides in solutions,.

  3. ICRP 2015. International symposium on the radiation protection system. Report and reflection on a significant symposium; ICRP 2015. 3. Internationales Symposium zum System des Strahlenschutzes. Bericht und Reflexion ueber ein bedeutsames Symposium

    Energy Technology Data Exchange (ETDEWEB)

    Lorenz, Bernd

    2016-08-01

    The ICRP international symposium on the radiation protection system provides always extensive information on new developments in radiation protection. The ICRP 2105 discussed the following issues: radiation effects of low dose irradiation, dose coefficients for internal and external exposures, radiation protection in nuclear medicine, application of ICRP recommendations, environmental protection, studies on existing exposure situations, medical radiation protection today, science behind radiation doses, new developments in radiation effects, and ethics in radiation protection.

  4. La revolution des savants

    CERN Document Server

    Chavanne, A

    1989-01-01

    Premiere cassette : - 1666 : impact de la creation de l'Academie des Sciences par Colbert, trente ans apres le proces de Galile, et au moment des disparitions de Pascal, Descartes et Fermat. Elle dirigee par le hollandais Huyggens jusqu'a sa fuite de France au moment de la revocation de l'Edit de Nantes. - 1750 : l'Encyclopedie (ou "Dictionnaire raisonne des Sciences, des Arts et des Metiers") de Diderot et d'Alembert, soutenus par Malherbes, Buffon, Condorcet et Rousseau. - 1789 : Revolution francaise. - 8 aout 1793 : l'Assemblee, par une declaration de Marat, dissout l'Academie des Sciences. Celle-ci continue cependant ses travaux pour les poids et mesures jusqu'en 1795. - la Terreur : la condamnation a mort, pas au nom d'une "Revolution qui n'a pas besoin de savants" mais pour d'autres raisons, de trois grands hommes de science : Lavoisier, Bailly et Condorcet. - 1793-1794 : Au printemps 93, le Comite de Salut Publique s'inquiete du demi-million de soldats etrangers de toutes les pays frontaliers qui essai...

  5. Priorities in radiation protection. Propositions for a better protection of persons against the danger of ionizing radiations. Report of the Vrousos commission; Priorites en radioprotection. Propositions pour une meilleure protection des personnes contre les dangers des rayonnements ionisants. Rapport de la commission Vrousos

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-03-15

    this report presents priorities for actions and recommendations on subjects such communication, information, education, and also research, monitoring of technological development, expertise or giving users more responsibility. these recommendations are given with actions propositions on field of workers radiation protection or patients protection or radioactive sources management. (N.C.)

  6. Growth and characterization of single-crystal CVD diamond for radiation detection applications; Synthese et caracterisation de diamants monocristallins pour applications de detecteur de rayonnements

    Energy Technology Data Exchange (ETDEWEB)

    Tranchant, N

    2008-01-15

    This work aimed at the study of the synthesis of single crystal diamond using the Microwave enhanced Chemical Vapour Deposition technique (MPCVD). The work enabled the development and optimisation of the growth conditions, from the study of the crystalline quality, of the material purity, and of its electronic properties. The assessment of the transport properties was the most determinant: the use of the time of flight (TOF) technique has enabled the measurement of the carrier mobilities and of their kinetic properties as a function of the temperature. When coupled with collected charge efficiency measurements, the work led to remarkable carrier mobility values obtained in the synthesised crystals (3000 cm{sup 2}.V-1.s{sup -1}). Prepared samples were mounted as detection devices and used successfully in real conditions for the monitoring of ultra-fast pulses, as well as for neutron fluency monitoring, and for medical dosimeters for radiotherapy applications. (author)

  7. Contribution des radios communautaires a l'education des ...

    African Journals Online (AJOL)

    Contribution des radios communautaires a l'education des populations rurales pour un developpement durable au Benin: etude de cas. ... Journal de la Recherche Scientifique de l'Université de Lomé. Journal Home · ABOUT THIS JOURNAL ...

  8. Radiation exposure to the patient caused by single-photon transmission measurement for 3D whole-body PET; Die Strahlenexposition des Patienten durch die Einzelphotonen-Transmissionsmessung bei der PET

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, A.; Donsch, P.; Kirsch, C.M. [Universitaet des Saarlandes, Homburg/Saar (Germany). Abt. fuer Nuklearmedizin; Seifert, H. [Universitaet des Saarlandes, Homburg/Saar (Germany). Abt. Strahlentherapie der Radiologischen Klinik

    2000-11-01

    Aim: The aim of the study was the determination of the radiation exposure to the patient caused by single-photon transmission measurement for 3D whole-body PET. Material and method: Single-photon-transmission measurement is performed using two Cs-137 pointsources (E{gamma}=662 keV, A=2*614 MBq) on a 3D PET scanner (ECAT ART). During a simulation of a whole body transmission scan (axial length: 75 cm, 6 contigous bed positions) dose measurements with thermoluminescent dosimeters were carried out using a thorax and an abdomen phantom. Following the guidelines of the ICRU report No. 60 an estimation of the effective dose caused by a single-photon transmission measurement was calculated. Results: For a total acquisition time of 360 min (6 beds with an acquisition time of 60 min per bed) the absorbed doses amounted to: Surface (xyphoid) 189 {mu}Gy, heart 196 {mu}Gy, lungs 234 {mu}Gy, vertebra 240 {mu}Gy, liver 204 {mu}Gy, gonads 205 {mu}Gy, thyroid 249 {mu}Gy and bladder 185 {mu}Gy resulting in a conversion factor of 1.7*10{sup -4} mSv/(h*MBq). The estimation of the effective dose for a patient's transmission (acquisition time of 3.2 min per bed) yields a value of 11 {mu}Sv. An estimation of the ratio of the conversion factors for transmission measurements in single-photon- and in coincidence mode (two Ge-68/Ga-68 rod sources of 40 MBq each), respectively, resulted in a value of 0.18. The comparison of the effective doses caused by single-photon transmission and by emission measurement (injection of 250 MBq of FDG) yields a ratio of 2.3*10{sup -3}. Conclusion: The radiation exposure of the patient caused by the transmission measurement for 3D whole-body-PET can be neglected. In comparison with the coincidence-transmission using uncollimated line sources of low activity the radiation exposure is still reduced using single photon transmission with collimated point sources of high activity. (orig.) [German] Ziel: Ziel war die Bestimmung der Strahlenexposition des

  9. La convergence des rôles respectifs des relationnistes et des journalistes influence-t-elle la perception qu'ils ont les uns des autres?

    DEFF Research Database (Denmark)

    Valentini, Chiara

    2017-01-01

    la convergence des rôles respectifs des praticiens des relations publiques et des journalistes a un effet favorable sur la perception qu’ils ont les uns des autres. L’effet est plus marqué chez les praticiens des relations publiques, car leur vision de la profession en journalisme correspond à celle...

  10. Application of Nuclear Radiation to Textile Materials and Processes. Radiation-induced graft copolymerization of vinyl monomers and fibrous polymers; Applications des rayonnements aux textiles. Formation radiochimique de copolymeres ''greffes'' par l'action de monomeres vinyliques sur des polymeres en fibre; Primenenie yadernogo izlucheniya v tekstil'noj promyshlennosti. Obrazovanie privitykh sopolimerov iz vinilovykh monomerov i voloknistykh polimerov pod dejstviem izlucheniya; Aplicaciones de las radiaciones nucleares a los procesos y materiales textiles. Copolimerizacion por injerto radioinducida de monomeros vinilicos y de polimeros fibrosos

    Energy Technology Data Exchange (ETDEWEB)

    Armstrong, Jr., A. A.; Rutherford, H. A. [University of North Carolina at Raleigh, NC (United States)

    1963-11-15

    A technique has been developed that permits the radiation grafting of volatile vinyl monomers to fibrous polymers in a uniform manner. It involves the addition of the organic compound from the vapour phase, and the process may be done by either a mutual or a pre-irradiation process using cobalt-60. Systems that accelerate the rate of graft copolymerization have been studied, and it is possible to add significant amounts of several of the monomers without radiation damage to the fibre substrate. The fibrous materials that are relatively unstable toward radiation are the ones that add the vinyl compounds the most readily. These are the celluloses, celluloseesters, polyamides, and polypropylene. The addition of the monomer to the fibre substrate apparently takes place by a free-radical mechanism and, as already indicated above, it is possible to irradiate the material first and subsequently obtain grafting by exposure of the irradiated material to the monomer vapour. Attempts have been made to determine the life of the free-radicals and while it has been difficult to obtain exact figures, it has been demonstrated that they may continue to exist in some fibres for15 to 20 hr after irradiation, even at room temperature. Preliminary experimental evidence has also suggested that the diffusion time of the monomer to free-radical sites in post-irradiation grafting proceeds at different rates in the different fibres. The modification of cotton by the addition of polyacrylonitrile results in a fibre almost completely resistant to micro-organisms. Only 3.5% deposition is required and the material retains the appearance and feel of untreated cotton. The product is superior to that made by the addition of acrylonitrile using the ironperoxide catalyst system. Polypropylene may be grafted with several different monomers to produce a fibre that is dyeable by commonly-used dyeing procedures. At the present stage of development, however, the wash fastness of the grafted and dyed

  11. Study of the cell cycle control for human malignant mesothelioma lines. Interferon and radiations effect; Etude de la regulation du cycle cellulaire de lignees de mesotheliome malin humain. Effet de l'interferon et des radiations

    Energy Technology Data Exchange (ETDEWEB)

    Vivo, C

    1999-07-01

    In order to better understand the inhibition mechanisms of the IFN-R-HU on tumoral development, the IFN-R-U effect on MM lines has been studied. Three groups of lines has been distinguished: eight sensitive lines, two intermediate and three resistant. The sensitive lines showed a triple locking of the cell cycle: in phases S, G1 and G2. The study of the cell cycle control points function, realized by the MM lines radiation exposure showed the points function on G1/S and-or on G2/M and the dependence or non dependence of the cycle stop of the protein P53 and P21 W at F1/CIP1. (A.L.B.)

  12. Promouvoir l'entrepreneuriat inclusif des jeunes et des femmes ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Le projet vise à analyser la contribution réelle et potentielle de l'entrepreneuriat inclusif au bien-être des jeunes et des femmes en Côte d'Ivoire, au Burkina Faso et au Kenya. Après un état des lieux de la pratique de l'entrepreneuriat inclusif dans chacun des pays ciblés, l'équipe de recherche étudiera son incidence sur ...

  13. La fabrique des sciences des institutions aux pratiques

    CERN Document Server

    Benninghoff, Martin; Crettaz von Roten, Fabienne; Merz, Martina

    2006-01-01

    Aujourd'hui, les façons de produire, d'organiser, d'évaluer et d'utiliser les savoirs sont en profond débat. De plus en plus, l'Etat, la société civile et l'économie tentent d'influencer les activités des universités et des laboratoires de recherche. Ces développements mettent à l'épreuve tout à la fois les fondements des systèmes d'enseignement supérieur et de recherche, l'autonomie des institutions scientifiques, la définition des frontières des savoirs et l'acceptation des sciences. Dans des contextes suisses et européens, cet ouvrage s'intéresse aux manières dont les sciences et les technologies sont fabriquées, en analysant leurs institutions et les pratiques. A partir d'une approche relationnelle, les sciences et les technologies sont conçues comme des phénomènes profondément sociaux, culturels et politiques. Une telle démarche déstabilise les visions parfois idéalisées et stéréotypées de la construction des savoirs. Des études de cas détaillées décrivent des phénomè...

  14. Effets des extraits vegetaux sur la dynamique de populations des ...

    African Journals Online (AJOL)

    La présente étude se propose de trouver une alternative de l'utilisation des pesticides chimiques en testant l'effet insecticide des extraits aqueux des feuilles de Hyptis suaveolens, graines de Ricinus communis et de Azadirachta indica contre les ravageurs du niébé en conditions de champ en utilisant le cyperméthrine ...

  15. Atmospheric Propagation Effects through Natural and Man-Made Obscurants for Visible to MM-Wave Radiation (Les Effets des Conditions Defavorables de Propagation sur les Systemes Optiques, IR et a Ondes Millimetiques)

    Science.gov (United States)

    1993-11-01

    satisfying certain data-quality Figure l(b) shows plots of p(Vwo) for a0 =- m2 and p(V.) for criteria were included in the data base. For each terrain cat ...RESUME 0naX0. - 2A Le Principe d’un syst~me pour Ia granulom ~trie par na.O) N R~ diffusion de lumi~re des particules d’un milieu tr~s faiblement...distribution en taille des airosols atxnosph6riques. G~n~ralement. Ia distribution en taille d’atdrosols par = ga)d mesures de diffusion "in-situ" cat

  16. Charte du Conseil des Gouverneurs

    International Development Research Centre (IDRC) Digital Library (Canada)

    Office 2004 Test Drive User

    7. favoriser des communications ouvertes et franches entre le personnel, la direction ..... de dresser le procès-verbal des réunions du Conseil et de ses comités et de veiller à ce ... et des résultats qu'il obtient, et non de sa gestion quotidienne.

  17. The Use of Ionizing Radiation as a Means of Processing Foodstuffs for Storage: Present Status and Future Prospects; Utilisation des Rayonnements Ionisants pour la Conservation de Produits Alimentaires: Situation Actuelle et Perspectives; Sostoyanie i perspektivy primeneniya ioniziruyushchikh izluchenij dlya obrabotki pishchevykh produktov v svyazi s ikh khraneniem; Estado Actual y Perspectivas del Empleo de las Radiaciones Ionizantes para la Conservacion de los Productos Alimenticios

    Energy Technology Data Exchange (ETDEWEB)

    Rogachev, V. I. [Vsesojuznyj Nauchno-Issledovatel' skij Institut Konservnoj i Ovoshesushil' noj Promyshlennosti Moskva, SSSR (Russian Federation)

    1966-11-15

    The use of ionizing radiation for processing foodstuffs is being studied in the USSR, particularly in connection with the following: (a) prevention of sprouting in potatoes and onions; (b) disinfestation of foodstuffs; (c) suppression of microbe activity; either sterilization or partial inhibition of microflora activity to prolong the shelf life of various foodstuffs; and (d) alterations in the ripening time of fruits and vegetables after picking and/or harvesting. The paper reports the status of work performed in the USSR during recent years on each of these general topics and the prospects for the practical application of irradiation to a number of products are considered. Among the products in question are meat and meat products (raw and cooked semi-finished products, sausage products), domestic poultry, various fruits and vegetables, potatoes, grain, dehydrated products (dried fruits and vegetables, dried food concentrates). Practical methods of irradiating potatoes and onions to prevent sprouting during storage have already been developed, and very soon it will be possible to use radiation for the disinfestation of foodstuffs on an industrial scale. (author) [French] Les etudes sur l'utilisation des rayonnements ionisants pour la conservation des produits alimentaires se poursuivent en URSS.dans les domaines suivants: a) prevention de la germination des pommes de terre et des oignons; b) desinsection des produits alimentaires; c) elimination de l'activite biologique des micro-organismes en vue de la sterilisation ou de l'elimination partielle de l'activite biologique de la microflore en vue de prolonger les delais de conservation de divers produits alimentaires; et d) modifications des delais de maturite apres recolte des fruits et legumes. Pour chacun de ces domaines, l'auteur indique l'etat des travaux effectues en URSS pendant ces dernieres annees et examine les perspectives d'utilisation des rayonnements pour un certain nombre de produits. Au nombre de ces

  18. Effects of Gamma Radiation on the Constituents of Wheat Flour; Action des Rayons Gamma sur les Elements Constitutifs de la Farine de Ble; Dejstvie gamma-luchej na sostavnye ehlementy muki; Accion de los Ratos Gamma Sobre los Elementos Constitutivos de la Harina de Trigo

    Energy Technology Data Exchange (ETDEWEB)

    Deschreider, A. R. [Laboratoire Central du Ministere des Affaires Economiques, Bruxelles (Belgium)

    1966-11-15

    certain authors have noted in the case of wheat receiving small gamma radiation doses. (author) [French] Des changements physiques, chimiques et biochimiques apparaissent dans les elements constitutifs de la farine irradiee par les rayons gamma. Ils dependent de l'origine de la farine, et sont d'autant plus importants que la dose de rayonnement est plus elevee. Les caroteno'ides de la fraction huileuse de.la farine diminuent sous l'action des radiations, puis disparaissent lorsque la dose atteint 4 Mrad. Quant aux lipides, ils sont le siege de reactions similaires a celles qui engendrent les hydroperoxydes; cependant, meme aux doses tres elevees, leur composition chimique n'est pratiquement pas affectee. La degradation importante de l'amidon indique que les polysaccharides de la farine sont les fractions les plus affectees par les irradiations. Cela entraine une augmentation des substances reductrices preexistantes et de l'indice maltose, parallele a l'elevation des doses appliquees. Mais l'accroissement de la production autolytique des sucres reducteurs est du, dans la farine irradiee, a une susceptibilite plus grande de l'amidon a l'hydrolyse par les diastases. La denaturation des polysaccharides provoque une chute de viscosite des empois d'amidon, due a l'augmentation de solubilite de l'amylopectine. En general, l'irradiation gamma diminue l'activite proteolytique de la farine et provoque, aux doses elevees, non seulement une denaturation partielle des proteines, mais egalement leur polymerisation et/ou leur condensation. Cette polymerisation peut s'expliquer par la reaction de radicaux libres avec les proteines du glut possedant des groupements -SH, et par la reaction de radicaux primaires entre eux au sein des macromolecules de proteines; ces phenomenes se produisent pendant l'irradiation. Les modifications des proteines provoquent des variations de la solubilite des albumine, gliadine et glutenine, ainsi que de la repartition centesimale des groupes qui les

  19. Le statut vitaminique des individus et des populations…

    Directory of Open Access Journals (Sweden)

    Icart Jean-Claude

    2000-05-01

    Full Text Available Comme le souligne un récent rapport du Haut comité de santé publique, le statut vitaminique des individus et des populations demeure une question d’actualité. Si les études ne révèlent plus de signes évocateurs de carence, au plus des problèmes de déficiences pour certains groupes à risque, des interrogations, demeurent malgré le contexte d’abondance, concernant la couverture des besoins, laquelle pourrait s’avérer inférieure aux valeurs considérées comme satisfaisantes.

  20. Les lueurs des sables

    CERN Multimedia

    Les lueurs des sables

    2013-01-01

    Two CERN ladies are getting ready for the “Trophée Roses des Sables” rally adventure: Julie and Laetitia are finalizing the last details before setting off on Monday 7th October 2013. Julie from EN-MEF group and Laetitia from DGS-SEE group, met at the CERN Rugby club. This year, they are participating in the 100 % female rally which will take place in Morocco from 10 to 20 October. They will be carrying along 100 kg of humanitarian donation for children such as some clothes, books and medical material. Do not hesitate to show your support at their farewell party to be held on Monday 7 October, from 4 to 6 pm in front of the St Genis-Pouilly Mairie (city Hall). Follow their exciting adventure on the blog leslueursdessables.trophee-roses-des-sables.org and on their association’s Facebook page Les Lueurs des Sables.

  1. Liste des auteurs

    OpenAIRE

    2016-01-01

    Madeleine Akrich      Ecole des Mines – Centre de Sociologie de l’innovation – Paris Noël Barbe      Association comtoise des Arts et Traditions populaires – Besançon Lucien Bernot      Ecole des hautes études en sciences sociales (EHESS) – Paris Anni Borzeix      Centre national de la recherche scientifique (CNRS) –     Groupement d’intérêt public (GIP) « Mutations industrielles » – Paris François Boudarias      Laboratoire d’Anthropologie et de sociologie de Tours (LAST) Dominique Boullier ...

  2. A study of filtering problems of background noise in nuclear spectrometry, improvement of signal-to-noise ratio, and of pulse characteristics produced by the optimum predictor device; Etude de problemes de filtrage de bruit de fond en spectrometrie nucleaire, amelioration du rapport signal sur bruit et des caracteristiques de l'impulsion mise en forme par le dispositif du predicteur optimum

    Energy Technology Data Exchange (ETDEWEB)

    Benda, J [Commissariat a l' Energie Atomique, 91 - Saclay (France). Centre d' Etudes Nucleaires

    1967-05-01

    The purpose of nuclear spectrometry is the precise measurement of particles energy. The resolving power of a spectrometer design is an important factor. Two main phenomena are involved in the limitation of this resolving power: The statistical fluctuations of the detector itself, and the background noise. For a given noise, the theory of filters enables the calculation of networks specially designed for the improvement of signal to noise ratio. The proposed system should lead to an improvement of 10.5 per cent of this ratio. Experiments have confirmed this theoretical estimation. The predictor device also makes possible the obtaining of shortened pulses. (author) [French] Les mesures en spectrometrie nucleaire ont pour but la determination precise de l'energie des particules. Le pouvoir de resolution d'une chaine de spectrometrie est une caracteristique importante. Deux phenomenes principaux concourent a limiter ce pouvoir de resolution: les fluctuations statistiques du detecteur et le bruit de fond. Pour un bruit de fond donne, la theorie des filtres permet de calculer des reseaux susceptibles de modifier le rapport signal sur bruit. Le systeme propose permet d'ameliorer de 10.5 pour cent ce rapport lorsqu'on se place dans les conditions optimales. Les resultats experimentaux confirment les previsions. Le dispositif predicteur permet aussi un raccourcissement de l'impulsion dans le temps. (auteur)

  3. Évaluation des pratiques agricoles des légumes feuilles : le cas des ...

    African Journals Online (AJOL)

    Face à ce constat, le défi de la recherche serait la détermination du niveau actuel de contamination des légumes feuilles et des eaux du barrage et celui de l'État serait l'initiation de programmes de sensibilisation des producteurs par rapport à une gestion plus rigoureuse des pesticides. Mots-clés : pratiques paysannes, ...

  4. The use aeroplanes and vehicles for prospecting. The technique of the detection radioactivity. The future opened up by the use of the discrimination of energies; Methodes de prospection autoportee et aeroportee. La technique de la detection des rayonnements. Les perspectives offertes par la discrimination des energies

    Energy Technology Data Exchange (ETDEWEB)

    Guitton, J; Berbezier, J; Blangy, B; Lallemant, C [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    The idea of installing activity detectors on aeroplanes and vehicles has been widely applied by the CEA since the start of prospecting in the arid and tropical regions of the Communaute Francaise. Three systems of detection have been developed and compared in a systematic manner: a group of 50 G.M. tubes; the sodium iodide scintillator; the plastic scintillator. The sodium iodide scintillator is used as a standard reference; the results are compared by graphical recording. Airborne prospecting is carried out in two stages: the initial flights, which follow a kilometre square network, make possible the discovery of the most likely zones; these likely zones are then examined in greater detail using light aeroplanes or helicopters. The two types of airborne scintillation measuring devices which have been developed by the CEA are described in this article. The practical results obtained during systematic and detailed airborne prospecting campaigns in the Hoggar are described. The difficulty in airborne uranium prospecting is to be able to immediately distinguish while in flight, anomalies caused by uranium from those caused by thorium. (author) [French] L'idee de monter des detecteurs de rayonnements sur des avions ou des vehicules a ete largement appliquee par le CEA des le debut des prospections dans les pays sahariens et tropicaux de la Communaute Fran ise. On a realise et compare d'une maniere systematique trois moyens de detection: groupe de 50 tubes GM; scintillateur d'iodure de sodium, scintillateur plastique. L'appareil de reference sera le scintillateur d'iodure de sodium; les resultats sont compares par enregistrement graphique. La prospection aeroportee se fait en deux etapes; les premiers vols systematiques suivant un quadrillage kilometrique permettent de reperer les zones interessantes; ces dernieres font l'objet d'examens plus detailles effectues en avion leger ou en helicoptere. Dans cet article, on decrit les deux types de scintillometres aeroportes

  5. Installation for Studying the Scattering of Cold Neutrons; Installation pour l'etude de la diffusion des neutrons thermiques; Ustanovka dlya izucheniya rasseyaniya kholodnykh nejtronov; Instalacion para estudiar la dispersion de neutrones frios

    Energy Technology Data Exchange (ETDEWEB)

    Golikov, V V; Shapiro, F L; Shkatula, A; Yanik, E A [Ob' edinennyj institut yadernykh issledovanij, Dubna, Union of Soviet Socialist Republics (Russian Federation)

    1963-01-15

    Using the pulsed fut reactor in the Joint Institute for Nuclear Research, an installation was set up to investigate the spectrometry of cold neutrons. The moderator, adjoining the reactor reflector, and the beryllium filter were at the temperature of liquid nitrogen. The scatterer, located at a distance of about 0. 6 m from the moderator, was irradiated by flashes of cold neutrons, whose duration was determined by the lifetime of the neutrons in the moderator and the dispersion of the times-of-flight over a distance of 0. 6 m. The frequency of the flashes was 8/s. The steep beryllium edge of the spectrum, lying around 200 {mu}s, was used for spectrometry in the quasi-elastic range. The energy of the scattered neutrons was determined by the time-of-flight over the distance between scatterer and detector, which was about 10-40 m. ZnS + 10{sub 2}{sup 10} O{sub 3} scintillation detectors with surfaces of 300 and 2 000 cm{sup 2} were used and the efficiency, for fast neutrons, was about 60%. (author) [French] A l'aide du reacteur a flux pulse de neutrons rapides de l'Institut unifie de recherches nucleaires, les auteurs ont mis au point une installation pour la spectrometrie des neutrons thermiques. Le ralentisseur contigu au reflecteur du reacteur et le filtre deberyllium sont maintenus a la temperature de l'azote liquide. Le diffuseur, place a environ 60 cm du ralentisseur, est irradie par une bouffee de neutrons thermiques dont la duree est determinee par la vie moyenne des neutrons dans le ralentisseur et par l'etalement des temps de vol necessaires pour parcourir la distance de 60 cm. La frequence des bouffees est de 8/s. Pour la spectrometrie dans la region quasi-elastique, on utilise la bande en bordure du spectre qui correspond au beryllium et s'etale sur environ 200 {mu}s. L'energie des neutrons diffuses est determinee par la duree du parcours entre le diffuseur et le detecteur. Les auteurs ont utilise des detecteurs a scintillation a ZnS + 10{sub 2}{sup 10} O

  6. Application des TIC à l'atténuation des effets des catastrophes dans ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    L'Amérique centrale est souvent aux prises avec des inondations et des ... (SIG) et de traitement des images, afin de cartographier les dangers et de modéliser les ... de l'Institut d'étude du développement international de l'Université McGill.

  7. Processing of data issued from {gamma} spectrometer. Application to the study of decay schemes; Traitement des informations issues d'un spectrometre {gamma}. Application a l'etude de schemas de desintegration

    Energy Technology Data Exchange (ETDEWEB)

    Boulanger, J P; Legrand, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    The main purpose of the following report is the study of a generation method of {gamma} spectra corresponding to any energy, from a library of some basic spectra. Then we point out how to establish the decay scheme of a radio-nuclide, in using an accurate analysis of full-energy peaks which appear in its complex spectrum, followed by a generation of plain spectra corresponding to the energies of the different transitions, and ending with a least-squares fitting procedure of the complex spectrum. The accuracy of the process is examined comparing the calculated spectra to the ones issued from two kinds of spectrometers (Na I(Tl) and Ge(Li)). The method is then applied to the study of {sup 134}Cs and {sup 95}Zr - {sup 95}Nb. (authors) [French] Le present rapport a pour principal objet l'etude d'une methode de generation de spectres {gamma} correspondant a n'importe quelle energie, a partir d'une bibliotheque de quelques spectres de reference. On montre ensuite comment on peut etablir le schema de desintegration d'un radionucleide, a l'aide d'une analyse precise des pics d'absorption totale apparaissant dans son spectre complexe, suivie d'une generation des spectres simples correspondant aux energies des diverses transitions, et en terminant par une decomposition du spectre complexe par la methode des moindres carres. On examine la validite du procede en comparant les spectres calcules a ceux obtenus avec deux types de detecteurs (scintillateurs et semi-conducteurs). On applique alors la methode a l'etude du {sup 134}Cs et du {sup 95}Zr - {sup 95}Nb. (auteurs)

  8. Measurement of the fission cross-section of {sup 235}U and {sup 239}Pu for thermal neutrons; Mesures des sections de fission de {sup 235}U et de {sup 239}Pu en neutrons thermiques

    Energy Technology Data Exchange (ETDEWEB)

    Fraysse, G; Prosdocimi, A; Netter, F; Samour, C [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-07-01

    Improved techniques of fast detection have been applied for determining the fission cross-sections of {sup 235}U and {sup 239}Pu with reference to the absorption cross-section of Boron. Monochromatic neutron beams of 0.0322 eV, 0.0626 eV and 0.275 eV have been employed. Use has been made of a Xe-filled gaseous scintillator and of a low-geometry solid state ion chamber. Both measured alpha and fission rates. The results at the reference energy of 0.0253 eV are: ({sigma}{sub F}){sub 0} {sup 235}U = 588 {+-} 10 barns ({sigma}{sub F}){sub 0} {sup 239}Pu = 738 {+-} 7 barns. (authors) [French] Des techniques avancees de comptage rapide ont ete mise en oeuvre pour determiner la section efficace de fission de {sup 235}U et de {sup 239}Pu par rapport a celle d'absorption du bore. Des faisceaux de neutrons monochromatiques de 0,0322 eV, 0,0626 eV et 0,275 eV ont ete employes. Les detecteurs utilises sont un scintillateur gazeux rempli de xenon et une chambre d'ionisation a etat solide a basse geometrie. Les deux ont mesure les taux des desintegrations alpha et des fissions. Les resultats a l'energie de reference de 0,0253 eV sont: ({sigma}{sub F}){sub 0} {sup 235}U = 588 {+-} 10 barns ({sigma}{sub F}){sub 0} {sup 239}Pu = 738 {+-} 7 barns. (auteurs)

  9. Development of Radiation-Sterilized Sea Food Products. I. Enzyme-Inactivated Cod and Halibut Patties; Essais de Radiosterilisation des Produits Alimentaires d'Origine Marine. I. Pates de Morue et de Fletan a Enzymes Inactives; Primenenie izlucheniya dlya sterilizatsii morskikh pishchevykh produktov; Preparacion de Alimentos de Origen Marino Esterilizados por Irradiacion. I. Pastelillos de Bacalao y de Hipogloso con Enzimas Inactivadas

    Energy Technology Data Exchange (ETDEWEB)

    Sinnhuber, R. O.; Landers, Mary K.; Yu, T. C. [Department of Food Science And Technology, Oregon State University, Corvallis, OR (United States); Simon, M.; Heiligman, F. [United States Army Natick Laboratories, Natick, MA (United States)

    1966-11-15

    Radiation-sterilized enzyme-inactivated cod (Gadus macrocephalus) and halibut (Hippoglossus stenolepsis) patties or cakes were developed which show promise as commercial products. They were prepared by incorporating the comminuted fish with white corn meal, gelatin, and salt and forming the mixture into sausages. Enzymes were inactivated by heating the sausages in a boiling water-bath. After cooling overnight to set the protein, the sausages were sliced into 3/8-in-thick patties, packed in cans and given a radiation dose of 4.5 Mrad. The radiation sterilized products were stored for 12 months at 72 Degree-Sign F with periodic evaluations to assess the quality and the effect of various treatments. The treatments included vacuum packing, the addition of various antioxidants, and the use of charcoal packets. The products just prior to serving were dipped in batter and breading and deep-fried. The fish patties were evaluated by flavorpanels and objective measurements, such as total volatile bases, 2-thiobarbituric acid number, pH and colorrreflectance values. The products received acceptable flavor scores from preference panels (140 to 170 judges) during twelve months of storage at 72 Degree-Sign F. Although the panels preferred the non-irradiated control samples to the irradiated samples after 12 months, all stored irradiated patties scored on the ''like'' side of the 9-point hedonic scale. The color-reflectance values of radiation-sterilized seafood products can be used as a measure of the radiation-induced browning and seemed to correlate with length of storage. (author) [French] Les auteurs ont mis au point des pates ou hachis de morue (Gadus macrocephalus) et de fletan (Hippoglossus stenolepsis) a enzymes inactives, sterilises par rayonnement, qui semblent pouvoir etre commercialises. Ils ont ete prepares par malaxage du poisson finement hache avec de la farine de mais blanche, de la gelatine et du sel, le melange etant debite sous forme de saucisses. Les enzymes

  10. Survey of boron detectors for thermal neutrons operating in the non proportional regime; Etude de detecteurs a bore pour neutrons thermiques fonctionnant en regime non proportionnel

    Energy Technology Data Exchange (ETDEWEB)

    Vacarie, J [Commissariat a l' Energie Atomique, 38 - Grenoble (France). Centre d' Etudes Nucleaires

    1968-07-01

    In gas counters, the alternative of directly detecting (i.e. without using the phenomenon of multiplication the charges ionized by the reaction {sup 10}B (n,{alpha}){sup 7}Li, offers many advantages as to the conception of such a detector. After examining the ionization phenomenon and deducing the characteristics of low-noise amplifiers, various prototypes are studied. - The D.I.N. 5/4, intended for fast neutrons detector, grants leave to have good isotropic proprieties thanks to its geometry and good sensitivity imputable to the BF{sub 3} filling pressure of 1 atm. - A flat counter (D.E.H. type), with plane and parallel electrodes, grants leave to work out a low height of influence, soil moisture measurer. The confrontation between various filling pressures (0.5, 1, 2, 3 atm.) points out the importance of attachment in BF{sub 3}. - Thanks to neutronic diffraction counter (C.D.N. 2 type) filled under 2 atm and parallelepiped, one can considerably reduce the weight of the goniometer protection, and lightly increase its sensitivity. - The results given by the experimental boron coating device have allowed to build a boron coating counter to be used in current collection. (author) [French] Dans les compteurs a gaz, la possibilite de detecter directement (c'est-a-dire sans utiliser le phenomene de multiplication) les charges ionisees lors de la reaction {sup 10}B (n,{alpha}){sup 7}Li offre de nombreux avantages pour la conception de detecteurs a bore. Apres avoir examine les phenomenes d'ionisation et en avoir deduit les caracteristiques de la chaine d'amplification faible-bruit, on etudie les differents prototypes developpes. - Le D.I.N. 5/4 destine a une sonde de neutrons rapides, permet d'avoir une bonne isotropie grace a sa geometrie et une bonne sensibilite due a sa pression de remplissage de 1 atm. en BF{sub 3}. - Un compteur plat (type D.E.H.) a electrodes planes et paralleles permet de realiser un humidimetre a faible hauteur d'influence. La comparaison de

  11. REPRISE DES COURS - Yoga

    CERN Multimedia

    Club de Yoga

    2015-01-01

    REPRISE DES COURS – Venez nombreux ! Yoga, Sophrologie, Tai Chi La liste des cours pour le semestre allant du 1er septembre 2015 au 31 janvier 2016 est disponible sur notre site web : http://club-yoga.web.cern.ch Lieu Les cours ont lieu dans la salle des clubs, à l’entresol du restaurant No 2, Bât. 504 (dans la salle no 3 pour la Sophrologie). Prix des cours Le prix pour le semestre (environ 18 leçons) est fixé à 220 CHF plus 10 CHF d’adhésion annuelle au Club. Couple : 200 CHF par personne. 2 cours par semaine : 400 CHF. Inscriptions Les inscriptions aux cours seront prises directement auprès du professeur, lors de la 1ère séance. Avant de s’inscrire pour le semestre, il est possible d’essayer une séance gratuitement. Informations : http://club-yoga.web.cern.ch ----------------------------------------- cern.ch/club-yoga/

  12. Praxis des Klebens

    CERN Document Server

    Theuerkauff, Petra

    1989-01-01

    Bei diesem Buch handelt es sich um einen Leitfaden fur Klebepraktiker. Es werden die verschiedenen Einzelschritte beim kleben beschrieben, als auch die vorbereitenden Massnahmen und anschliessenden Prufverfahren auf Festigkeit behandelt. Das Buch sollte an keinem Arbeitsplatz fehlen, wo man sich mit Problemen der Fugetechnik des Klebens beschaftigt.

  13. Dimensions des stabulations 2018

    OpenAIRE

    Früh, Barbara; Maurer, Veronika; Schneider, Claudia; Schürmann, Stefan; Spengler Neff, Anet; Werne, Steffen

    2018-01-01

    Les «Dimensions des stabulations» contiennent toutes les dimensions pour les stabulations et les parcours pour la production animale en agriculture biologique. Cette liste sert d’instrument de planification pour les éleveurs, d’outil de travail pour la vulgarisation et d’ouvrage de référence pour le contrôle bio.

  14. Direction des Publications

    African Journals Online (AJOL)

    Synthese

    économique des services rendus par les écosystèmes marins. La richesse ... croissance plus rapide que la moyenne de l‟économie ...... services and natural capital. Nature. 387, 253-260. .... d‟interactions où l‟humain est partie prenante. In.

  15. La physique des infinis

    CERN Document Server

    Bernardeau, Francis; Laplace, Sandrine; Spiro, Michel

    2013-01-01

    Écrire l'histoire de l'Univers, tel est l'objectif commun des physiciens des particules et des astrophysiciens. Pour y parvenir, deux approches s'épaulent : la voie de l'infiniment petit, que l'on emprunte via de gigantesques accélérateurs de particules, et celle de l'infiniment grand, dont le laboratoire est l'Univers. Un Univers qui est bien loin d'avoir livré tous ses secrets. On connaît à peine 4,8 % de la matière qui le constitue, le reste étant composé de matière noire (25,8 %) et d'énergie noire (69,4 %), toutes deux de nature inconnue. Et si la récente découverte du boson de Higgs valide le Modèle standard de la physique des particules, celui-ci est toujours incomplet et doit être étendu à ou dépassé. Est-on arrivé au bout du jeu de poupées russes de la matière ? Quelles sont les particules manquantes ? Faut-il revoir les lois fondamentales ? Quels instruments faut-il mettre en œuvre pour accéder à cette « nouvelle physique » ? Comment parler de Super Big Science aux citoye...

  16. Establishment and Study of Dose Fields for the Irradiation of Experimental Animals with High-Energy Protons; Creation et Etude de Champs de Rayonnements pour l'Irradiation d'Animaux de Grande Taille par des Protons de Haute Energie; Sozdanie i issledovanie doznykh polej dlya oblucheniya ehksperimental'nykh zhivotnykh protonami bol'shoj ehnergii; Produccion y Estudio de Campos Radia Torios para la Exposicion de Animales de Laboratorio a Protones de Elevada Energia

    Energy Technology Data Exchange (ETDEWEB)

    Afanas' ev, V. P.; Keirim-Markus, I. B.; Kuznecova, S. S.; Litvinova, Je. G.; Sokolova, I. K.; Stukina, L. E.

    1964-03-15

    Present-day accelerators make it possible to obtain beams of protons which have adequate intensity but are not suitable for the general irradiation of large experimental animals. Using the synchrotron of the Joint Institute of Nuclear Research it has been shown that with the aid of absorbers it is possible to expand a proton beam to the dimensions required, without introducing the accompanying radiations. Dose fields, uniform within {+-} 10%, in which primary protons constitute between 99 and 88% of the tissue dose, were obtained for irradiation of dogs with protons of energy 510, 250 and 120 MeV. The tissue doses and the radiation composition were studied in a dog phantom. Irradiation conditions for ensuring uniform radiation of the dog's body are proposed. Various questions of high-energy proton dosimetry are discussed, and the use of different types of dosimeter are considered in this connection. The paper also describes a method of determining the contribution of cascade neutrons to the proton flux, using activation detectors. (author) [French] Les accelerateurs actuels permettent d'obtenir des faisceaux de protons d'une intensite suffisante mais impropres a l'irradiation generale de grands animaux d'experience. A l'aide du synchrocyclotron OIAI, on a montre que le recours aux absorbants permet d'elargir le faisceau de protons jusqu'aux dimensions voulues sans y introduire de rayonnements secondaires. Pour irradier des chiens par des protons de 510, 250 et 120 MeV, on a pu ainsi realiser des champs de rayonnements uniformes a {+-}10% pres, dans lesquels les protons primaires constituaient 99 a 88% de la dose tissulaire. Les auteurs ont etudie des doses tissulaires et la composition du rayonnement a l'interieur d'un fantome de chien. Ils indiquent dans quelles conditions on assure une irradiation uniforme du corps de l'animal. Les auteurs examinent plusieurs questions relatives a la dosimetrie des neutrons de grande energie. Ils justifient l'emploide divers

  17. Injectabilite des coulis de ciment dans des milieux fissures

    Science.gov (United States)

    Mnif, Thameur

    Le travail presente ici est un bilan du travaux de recherche effectues sur l'injectabilite des coulis de ciment dans lu milieux fissures. Un certain nombre de coulis a base de ciment Portland et microfin ont ete selectionnes afin de caracteriser leur capacite a penetrer des milieux fissures. Une partie des essais a ete menee en laboratoire. L'etude rheologique des differents melanges a permis de tester l'influence de l'ajout de superplastifiant et/ou de fumee de silice sur la distribution granulometrique des coulis et par consequent sur leur capacite a injecter des colonnes de sable simulant un milieu fissure donne. La classe granulometrique d'un coulis, sa stabilite et sa fluidite sont apparus comme les trois facteurs principaux pour la reussite d'une injection. Un facteur de finesse a ete defini au cours de cette etude: base sur la classe granulometrique du ciment et sa stabilite, il peut entrer dans la formulation theorique du debit d'injection avant application sur chantier. La deuxieme et derniere partie de l'etude presente les resultats de deux projets de recherche sur l'injection realises sur chantier. L'injection de dalles de beton fissurees a permis le suivi de l'evolution des pressions avec la distance au point d'injection. L'injection de murs de maconnerie a caractere historique a montre l'importance de la definition de criteres de performance des coulis a utiliser pour traiter un milieu donne et pour un objectif donne. Plusieurs melanges peuvent ainsi etre predefinis et mis a disposition sur le chantier. La complementarite des ciments traditionnels et des ciments microfins devient alors un atout important. Le choix d'utilisation de ces melanges est fonction du terrain rencontre. En conclusion, cette recherche etablit une methodologie pour la selection des coulis a base de ciment et des pressions d'injection en fonction de l'ouverture des fissures ou joints de construction.

  18. Screening phytochimique et identification spectroscopique des ...

    African Journals Online (AJOL)

    Origin

    plante, effectuée pour la première fois, a révélé la présence des alcaloïdes, des flavonoïdes, des tanins catéchiques, des terpènes, des coumarines et des composés cyanogénétiques. Quant aux saponines et les quinones libres, ils sont présents chez les fleurs et absents chez les feuilles. La caractérisation des molécules.

  19. The Effects of Cobalt-60 Gamma Radiation on Vitamin B{sub 6} and Folic Acid; Effets des rayons gamma (cobalt-60) sur la vitamine B{sub 6} et l’acide folique

    Energy Technology Data Exchange (ETDEWEB)

    Galatzeanu, I.; Antoni, F. [International Atomic Energy Agency, Vienna (Austria)

    1967-09-15

    A study has been made of the behaviour of pyridoxine and folic acid, including structural changes, after {sup 60}Co gamma irradiation. The irradiation of pyridoxine (vitamin B{sub 6}) and folic acid in aqueous solutions leads to their partial or total destruction, depending on the dose. The irradiation of pyridoxine and folic acid in the solid state mainly results in the elimination of hydrogen atoms (free radicals). After dissolving the irradiated samples in acid solutions it was observed that the irradiated molecule was renewed through replacement of the eliminated hydrogen atoms, which depend on the pH-value of the solution. This gives the possibility of sterilizing both pyridoxine and folic acid in the solid state by irradiation at 2 Mrad. Most of the radiolysis products of pyridoxine and folic acid irradiated in solution and in the solid state have been separated and identified by means of chromatography (paper and thin layer) and cellulose column electrophoresis. Electron spin resonance was used to determine the concentration and nature of the free radicals after irradiation of pyridoxine and folic acid in the solid state. (author) [French] On a Studie le comportement de la pyridoxine et de l'acide folique apres exposition aux rayons gamma ({sup 60}Co) et les changements dans leurs structures. L'irradiation de la pyridoxine (Vitamine B{sub 6}) et de l'acide folique en solutions aqueuses enttarne leur destruction partielle ou totale selon la dose. L'irradiation de la pyridoxine et de l'acide folique á l'etat solide enttarne principalement l'elimination d'atomes d'hydrogene (radicaux libres). Par dissolution des echanrilions irradies dans des solutions acides, on a observe un renouvellement de la molecule irradiee par remplacement des atomes d'hydrogene elimines qui est fonction du pH de la solution, ce qui permet de radiosteriliser a 2 Mrad á l'etat solide tant la pyridoxine que l'acide folique. On a separe et identifie la majorite des produits de radiolyse

  20. Some Possibilities of the Eddy-Current Method for Multi-Parameter Testing of Structural Components; Quelques Possibilites Offertes par la Methode des Courants de Foucault pour le Controle de Nombreux Parametres des Elements de Construction; Nekotorye vozmozhnosti metoda vikhrevykh tokov dlya mnogoparametrovogo kontrolya ehlementov konstruktsij; Algunas Posibilidades que Brinda el Metodo de las Corrientes de Foucault para Controlar Numerosos Parametros de los Elementos de Construccion

    Energy Technology Data Exchange (ETDEWEB)

    Vjahorev, V. G.; Gerasimov, V. G.; Deniskin, V. P.; Trahtenberg, L. I.; Shkarlet, Ju. M. [Gosudarstvennyj Komitet po Ispol' zovaniju Atomnoj Jenergii SSSR, Moskva, SSSR (Russian Federation)

    1965-09-15

    The paper discusses the pattern of occurrence of problems of non-destructive multiparameter testing in nuclear technology and the advisability of approaching these problems by the eddy-current method. The application of electric models is justified for solving testing problems using a long follow-through coil. Design formulae are given and the principles of designing applied eddy-current probes are explained. An arrangement for testing tube-wall thickness is described: in this apparatus the effect of movement of the tube under testing on the measurement results is eliminated with the aid of a servo-system controlled by a signal depending on the probe voltage phase. The paper describes how a self-oscillating circuit containing a test-coil is used as the probe of an apparatus for testing tubes. On the basis of calculated and experimental data various possibilities are indicated for the construction of single-frequency applied eddy-current testing probes for simultaneous measurement of more than two parameters. (author) [French] Les auteurs montrent que les problemes du controle non-destructif de plusieurs parametres en technologie nucleaire surgissent selon certaines lois et que la methode des courants de Foucault convient particulierement a la solution de plusieurs d'entre eux. Ils justifient l'utilisation de modeles electriques pour la solution des problemes de controle au moyen d'une longue bobine creuse. Us donnent des formules et exposent une methode pour le calcul de detecteurs a courants de Foucault. Us decrivent le schema d'un dispositif permettant de verifier l'epaisseur des parois de tubes, dans lequel le deplacement du tube a controler n'exerce aucune influence sur les resultats des mesures grace a l'emploi d'un moniteur actionne par un signal qui depend de la phase de tension du detecteur. Comme detecteur, on a employe un dispositif destine au controle des tubes d'un autogenerateur, apres avoir inclus dans son circuit une bobine d'essai. En partant des

  1. Efficacité des néonicotinoïdes et des pyréthrinoïdes utilisés contre le ...

    African Journals Online (AJOL)

    Efficacité des néonicotinoïdes et des pyréthrinoïdes utilisés contre le foreur des tiges du cacaoyer ( Eulophonotus myrmeleon Felder : Lepidoptera, Cossidae). Implications dans la stratégie de protection de la cacaoculture en Côte d'Ivoire.

  2. Radiosensitivity of Sitophilus Zeamais Mots (S. Oryzae L.) at Various Stages of Development: A Study of the Larval Stages by Means of Radiography and 'Actographic' Recording; Sensibilite des Divers Stades de Developpement de Sitophilus Zeamais Mots (S. Oryzae L.) aux Radiations Ionisantes Etude des Stades Endoges par Radiographie et Enregistrement Actographique

    Energy Technology Data Exchange (ETDEWEB)

    Pesson, P.; Girish, G. K. [Institut National Agronomique, Paris (France)

    1968-06-15

    The paper describes an original method of study, based on the employment of an 'actograph' which records the vitality of the larval stages and makes it possible to study the larva population inside grains (actograph for electro-acoustic detection developed by the INRA Acoustic Physiology Laboratory, Jouy-en-Josas). The contamination rate and the death rate of the larvae are observed by radiography. The effects of irradiation at doses of 2000, 4000, 8000 and 16000 rad are studied in the egg stage, on larvae aged 5-7 days, 13-15 days and 19-21 days and on adults, whose fertility is measured 0-5 days, 5-10 days and 10-15 days after irradiation. The effects of irradiation on the second generation bred from the various stages irradiated are noted. (author) [French] Les auteurs presentent une methode d'etude originale, fondee sur l'emploi d'un appareillage actographique, qui enregistre et traduit la vitalite des stades endoges et permet d'apprecier la population larvaire a l'interieur des grains (actogtaphe a detection electro-acoustique mis au point par le Laboratoire de physiologie acoustique de l'INRA, Jouy-en-Josas). Le controle du taux de contamination et de la mortalite larvaire se fait par radiographie. Les auteursont etudie les effets de l'irradiation (doses de 2000, 4000, 8000 et 16 000 rad)sur le stade oeuf, sur les larves agees respectivement de 5 a 7 jours, 13 a 15 jours, 19 a 21 jours et sur les adultes (fecondite 0 a 5 jours, 5 a 10 jours, 10 a 15 jours apres l'irradiation); ils ont egalement fait des observations sur les consequences de l'irradiation sur la seconde generation issue des divers stades irradies. (author)

  3. Automatic optimisation of beam orientations using the simplex algorithm and optimisation of quality control using statistical process control (S.P.C.) for intensity modulated radiation therapy (I.M.R.T.); Optimisation automatique des incidences des faisceaux par l'algorithme du simplexe et optimisation des controles qualite par la Maitrise Statistique des Processus (MSP) en Radiotherapie Conformationnelle par Modulation d'Intensite (RCMI)

    Energy Technology Data Exchange (ETDEWEB)

    Gerard, K

    2008-11-15

    Intensity Modulated Radiation Therapy (I.M.R.T.) is currently considered as a technique of choice to increase the local control of the tumour while reducing the dose to surrounding organs at risk. However, its routine clinical implementation is partially held back by the excessive amount of work required to prepare the patient treatment. In order to increase the efficiency of the treatment preparation, two axes of work have been defined. The first axis concerned the automatic optimisation of beam orientations. We integrated the simplex algorithm in the treatment planning system. Starting from the dosimetric objectives set by the user, it can automatically determine the optimal beam orientations that best cover the target volume while sparing organs at risk. In addition to time sparing, the simplex results of three patients with a cancer of the oropharynx, showed that the quality of the plan is also increased compared to a manual beam selection. Indeed, for an equivalent or even a better target coverage, it reduces the dose received by the organs at risk. The second axis of work concerned the optimisation of pre-treatment quality control. We used an industrial method: Statistical Process Control (S.P.C.) to retrospectively analyse the absolute dose quality control results performed using an ionisation chamber at Centre Alexis Vautrin (C.A.V.). This study showed that S.P.C. is an efficient method to reinforce treatment security using control charts. It also showed that our dose delivery process was stable and statistically capable for prostate treatments, which implies that a reduction of the number of controls can be considered for this type of treatment at the C.A.V.. (author)

  4. La gestion des résultats des entreprises innovantes

    OpenAIRE

    Dumas, Guillaume

    2014-01-01

    Cette thèse s’intéresse à la gestion des résultats dans le cadre des entreprises innovantes. Elle est constituée de trois articles. Dans le premier, il s’agit d’examiner si les résultats des entreprises innovantes sont gérés et si le stade de développement des innovations influence cette gestion des résultats. Il apparaît que les résultats des entreprises innovantes sont gérés à la hausse. Cette gestion ne semble intervenir qu’au cours de l’activité d’innovation (c’est-à-dire lorsque les entr...

  5. Chromosomes and irradiation: in vitro study of the action of X-rays on human lymphocytes; Chromosomes et radiations: etude in vitro de l'action des rayons X sur les lymphocytes humains

    Energy Technology Data Exchange (ETDEWEB)

    Mouriquand, C; Patet, J; Gilly, C; Wolff, C

    1966-07-01

    Radioinduced chromosomal aberrations were studied in vitro on leukocytes of human peripheral blood after x irradiation at 25, 50, 100, 200, and 300 R. The numeric and structural anomalies were examined on 600 karyotypes. The relationship between these disorders and the dose delivered to the blood are discussed. An explanation on their mechanism of formation is tentatively given. (authors) [French] L'etude in vitro des anomalies chromosomiques radioinduites a ete pratiquee sur des leucocytes de sang peripherique preleve chez 4 sujets et irradie aux doses de 25, 50, 100, 200, 300 R. Les aberrations numeriques et structurales ont ete examinees sur 600 caryotypes. Les rapports entre ces anomalies et les doses appliquees sont etudies. Une hypothese sur leur mecanisme de formation est avancee. (auteurs)

  6. Des dispositions responsables à prendre pour la protection des ...

    African Journals Online (AJOL)

    En considérant l'effet néfaste des maladies, des parasites, du changement climatique et d'autres facteurs environnementaux (les OGM par exemple) sur la survie des abeilles, la baisse de leurs populations dans certaines parties du monde ne saurait être attribuée aux seules pesticides. En plus, l'impact de ces derniers sur ...

  7. Aspects des Onychomycoses chez des patients camerounais de ...

    African Journals Online (AJOL)

    ... biologiques et évolutifs des onychomycoses chez des patients camerounais. Méthode : Il s'agit d'une étude rétrospective et descriptive menée de mars 2011 à mars 2014 dans l'unité de dermatologie de l'hôpital général de Douala (HGD), incluant des patients chez lesquels le diagnostic d'onychomycose avait été posé.

  8. Moderation of Neutrons Emitted by a Pulsed Source and Neutron Spectrometry Based on Slowing-Down Time; Ralentissement des Neutrons Emis par une Source Pulsee et Leur Spectrometrie en Fonction du Temps de Ralentissement; Zamedlenie nejtronov, ispuskaemykh impul'snym istochnikom, i spektrometriya nejtronov po vremeni zamedleniya; Moderacion de Neutrones Emitidos por una Pitente Pulsada y Espectrometria Neutronica Basada en el Tiempo de Frenado

    Energy Technology Data Exchange (ETDEWEB)

    Bergman, A. A.; Isakov, A. I.; Kazarnovskij, M. V.; Popov, Ju. P.; Shapiro, F. L. [Fizicheskij Institut Im. P.N. Lebedeva AN SSSR, Moskva, SSSR (Russian Federation)

    1965-08-15

    -sections. Measurements carried out on a large number of substances, including separated isotopes, have led to the discovery of hitherto unknown resonance levels with small neutron widths and have made it possible to determine for many nuclei the magnitude of the force function for the capture of neutrons with orbital angular momentum 1 = 1. (author) [French] A l'Institut de physique P. N. Lebedev de l'Academie des sciences de l'URSS, on a procede, au cours de ces six dernieres annees, a une serie de travaux visant a etudier le ralentissement non stationnaire des neutrons dans les milieux lourds, a elaborer une methode de spectro- metrie des neutrons en fonction du temps de ralentissement et a appliquer cette methode a l'etude de l'influence que l'energie exerce sur les sections efficaces des reactions nuceaires provoquees par des neutrons d'une energie de 30 keV ou moins. Les auteurs donnent un apercu de ces recherches et en analysent les resultats. Apres avoir examine brievement la theorie du ralentissement non stationnaire et de la thermalisation des neutrons, ils indiquent les donnees fournies par une etude experimentale du ralentissement des neutrons dans le graphite, le fer et le plomb et par l'etude de leur thermalisation dans le plomb. En utilisant une source de neutrons puisee et des detecteurs a resonance, ils ont mesure la distribution des temps de ralentissement pour une serie de valeurs determinees de l'energie finale des neutrons. Ils comparent les resultats obtenus a la theorie qui tient compte du mouvement thermique des atomes du ralentisseur, lequel provoque, dans le cas du plomb, une dispersion mesurable des temps de ralentissement pour des energies inferieures a 10 eV. Dans le domaine d'energies inferieures au seuil cadmium, on a mesure l'influence du temps de ralentissement sur la vitesse moyenne des neutrons dans le plomb; une comparaison a ete faite avec la theorie a plusieurs groupes. Les auteurs decrivent la methode employee pour determiner, selon le temps de

  9. Collection efficiency of charges in ionization chambers in presence of constant or variable radiation intensity; Efficacite de la collection des charges dans les chambres d'ionisation en presence d'une intensite de rayonnement ionisant constante ou variable

    Energy Technology Data Exchange (ETDEWEB)

    Decuyper, J [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1970-07-01

    The theoretical and experimental study of the collection of carriers built up by ionization in standard chambers, is made by varying the value of different acting parameters. In the presence of constant ionization intensity and under a D.C. and A.C. voltage, the effect of geometry, recombination, diffusion and attachment is analyzed. The compensation of thermal neutron D.C. chambers is equally considered. Under a time dependent ionization intensity and D.C. voltage, is then studied the effect of recombination on current response, and on the collection efficiency of all formed charges. (author) [French] L'etude theorique et experimentale de la collection des porteurs crees par ionisation dans les chambres couramment utilisees est entreprise en fonction de la valeur des differents parametres agissants. En presence d'une ionisation constante et sous une tension d'alimentation d'abord continue puis alternative, on analyse l'influence de la geometrie, de la recombinaison, de la diffusion et de l'attachement. La compensation des chambres a courant continu de mesure neutronique est egalement examinee. Ensuite, sous une intensite d'ionisation variable dans le temps et en alimentation continue, on etudie l'effet de la recombinaison sur la reponse en courant et sur l'efficacite de la collection de la charge totale liberee. (auteur)

  10. Usages des TIC et socialisation professionnelle des enseignants-chercheurs

    OpenAIRE

    Lavielle-Gutnik, Nathalie; Massou, Luc

    2013-01-01

    En prenant appui sur une nouvelle analyse des données recueillies dans l’enquête Tec-Meus (2008-2011, MSH Lorraine) sur la place accordée par des enseignants-chercheurs en sciences humaines et sociales aux technologies de l’information et de la communication (TIC) dans leur activité d’enseignement, nous souhaitons nous focaliser dans cet article sur la compréhension des processus de socialisation professionnelle en jeu dans leur usage déclaré des TIC. Par socialisation professionnelle, nous e...

  11. Direction des Publications

    African Journals Online (AJOL)

    Synthese

    Unité de Recherche des Matériaux et des Energies Renouvelables (U.R.M.E.R). Université Abou –Baker Belkaid B.p : 119 Tlemcen 13000 Algerie. 2. Unité de Développement de la Technologie Du Silicium. UDTS, BP 399, Alger, Algérie. Accepté le : 08/06/2011. صخلم. داوﻣﻟا نﻣ ﻲﺗﻟا ﺔﺻﺎﺧو ،ﺔﻋﺎﻧﺻ يأ رﯾوطﺗ ﻲﻓ ﺎﯾﺳﯾﺋر ﻼﻣﺎﻋ ةرﯾﺧﻷا تاوﻧﺳﻟا ...

  12. Mykotische Infektionen des Penis

    Directory of Open Access Journals (Sweden)

    Mayser P

    1999-01-01

    Full Text Available Die häufigste mykotische Infektion des Penis stellt die Balanitis/Balonoposthitis durch Candida albicans dar. Sie weist eine steigende Inzidenz auf und scheint vornehmlich durch Genitalverkehr übertragen zu werden. Penile Infektionen durch Dermatophyten sind sehr selten, obwohl die Tinea inguinalis zu den häufigeren Erkrankungen zählt. Eine Mitbeteiligung des Penis im Rahmen von Systemmykosen kennzeichnet zumeist ein schwer verlaufende Erkrankung. Ursächlich kann beim immunoinkompetenten Patienten nahezu jeder Erreger in Frage kommen. Biopsie sowie Gewebekultur aus den meist ulzerativen Veränderungen können die Diagnose sichern. Die meisten superfiziellen Infektionen sprechen zufriedenstellend auf eine topische antimykotische Behandlung an, insbesondere wenn Provokationsfaktoren und die Möglichkeit der sexuellen Transmission berücksichtigt werden. Ausgedehnte Infektionen durch Dermatophyten, Hefen und natürlich systemische Infektionen erfordern eine systemische antimykotische Therapie.

  13. Chimie des processus biologiques

    OpenAIRE

    Fontecave, Marc

    2014-01-01

    Cours : Chimie biologique radicalaire : de l’origine de l’ADN au métabolisme d’aujourd’hui Il est généralement admis que les radicaux libres, espèces chimiques très réactives, sont des poisons pour les systèmes vivants qui ont élaboré des mécanismes efficaces pour s’en protéger et s’en débarrasser lorsqu’ils viennent à se former, par accident. Par exemple ce qu’on appelle communément le stress oxydant est une situation caractérisée par une accumulation de radicaux issus de l’oxygène moléculai...

  14. La cogestion des Ressources naturelles

    International Development Research Centre (IDRC) Digital Library (Canada)

    L'eau, le sol, les nutriments, la lumière du soleil — ce sont des choses de la vie. .... habitent encore ces régions, soit de 9 % à 14 % de la population mondiale. ...... La guerre civile a fait vivre au Cambodge des années de chaos, d'anarchie et ...... et les allégeances politiques sont des facteurs qu'il est impossible d'ignorer.

  15. Des Ogle's old stump

    International Nuclear Information System (INIS)

    Jones, M.; Sutton, D.; Wallace, R.

    1998-01-01

    On 17 October 1997 Sylvia Bryan of RD4 Kaitaia wrote to 'Dear Somebody-Everybody' at the Anthropology Department, University of Auckland, urging further examination of an adzed stump found by Des Ogle during planting out of the Te Aupouri forest. The authors have since sought out relevant information and present it here for the interests of our readers. (author). 7 refs., 1 fig

  16. Diffusion of graphite. The effect of cylindrical canals; Longueur de diffusion du graphite effet des canaux cylindriques

    Energy Technology Data Exchange (ETDEWEB)

    Carle, R; Clouet d' Orval, C; Martelly, J; Mazancourt, T de; Sagot, M; Lattes, R; Teste du Bailler, A [Commissariat a l' Energie Atomique, Dir. Industrielle, Saclay (France). Centre d' Etudes Nucleaires; Robert, C [Ecole Normale Superieure, 75 - Paris (France)

    1957-07-01

    laplacien 1/L{sup 2} - l'effet des canaux qui modifie de fa n anisotrope l'equation de diffusion macroscopique et se caracterise par deux aires de diffusion principales (ou deux laplaciens principaux) valables respectivement pour la diffusion dans la direction des canaux et dans une direction perpendiculaire. Pour les determiner, deux experiences sont necessaires, dans lesquelles les derivees secondes du flux par rapport aux coordonnees d'espace soient tres differentes. Elles font l'objet des deux premieres parties. 1re Partie: Diffusion le long de l'axe d'un flux issu de la pile source et limite radialement par un ecran quasi cylindrique de barres de cadmium. Cet ecran, ou Cage de Faraday a pour but d'assigner au flux thermique propage le meme rayon d'extrapolation a zero que celui de la pile source. La determination de L (graphite plein) a ete faite dans les memes conditions. Deux voies ont ete employees pour l'interpretation des mesures. L'influence des cornieres portant les detecteurs est discutee. 2. Partie: Diffusion radiale dans le graphite entourant la pile cylindrique 'longue'. Elle est bien decrite par une somme de fonctions de Bessel. 3. Partie: Resultats (valables pour d = 1,61 t = 17 deg. C). Pour le graphite sans cavite L = 52,7 {+-} 0,4 cm. L'effet des canaux sur l'aire de diffusion et son anisotropie sont en excellent accord avec la theorie de Behrens: L(parallele) = 64,6 cm et L(perpendiculaire) = 62,2 cm. Appendice: Theorie de la cage de Faraday. (auteur)

  17. Grundlagen des Tissue Engineering

    Science.gov (United States)

    Mayer, Jörg; Blum, Janaki; Wintermantel, Erich

    Die Organtransplantation stellt eine verbreitete Therapie dar, um bei krankheitsoder unfallbedingter Schädigung eines Organs die Gesamtheit seiner Funktionen wieder herzustellen, indem es durch ein Spenderorgan ersetzt wird. Organtransplantationen werden für die Leber, die Niere, die Lunge, das Herz oder bei schweren grossflächigen Verbrennungen der Haut vorgenommen. Der grosse apparative, personelle und logistische Aufwand und die Risiken der Transplantationschirurgie (Abstossungsreaktionen) sowie die mangelnde Verfügbarkeit von immunologisch kompatiblen Spenderorganen führen jedoch dazu, dass der Bedarf an Organtransplantaten nur zu einem sehr geringen Teil gedeckt werden kann. Sind Spenderorgane nicht verfügbar, können in einzelnen Fällen lebenswichtige Teilfunktionen, wie beispielsweise die Filtrationsfunktion der Niere durch die Blutreinigung mittels Dialyse ersetzt oder, bei mangelnder Funktion der Bauchspeicheldrüse (Diabetes), durch die Verabreichung von Insulin ein normaler Zustand des Gesamtorganismus auch über Jahre hinweg erhalten werden. Bei der notwendigen lebenslangen Anwendung apparativer oder medikamentöser Therapie können für den Patienten jedoch häufig schwerwiegende, möglicherweise lebensverkürzende Nebenwirkungen entstehen. Daher werden in der Forschung Alternativen gesucht, um die Funktionen des ausgefallenen Organs durch die Implantation von Zellen oder in vitro gezüchteten Geweben möglichst umfassend wieder herzustellen. Dies erfordert biologisch aktive Implantate, welche die für den Stoffwechsel des Organs wichtigen Zellen enthalten und einen organtypischen Stoffwechsel entfalten.

  18. Dictionnaire des risques psychosociaux

    CERN Document Server

    Zawieja, Philippe

    2014-01-01

    Stress, suicide, harcèlement, épuisement professionnel, workaholism... Au-delà de la souffrance qu'elles désignent, ces notions souvent récentes constituent une approche inédite, et demandent à mieux être comprises, dans leur ensemble et isolément. C'est tout l'enjeu de ce dictionnaire, pionnier en son genre. Le lecteur y trouvera représentés, avec les 314 entrées (rédigées par 251 contributeurs) qui le composent, tous les champs disciplinaires s'intéressant à la souffrance au travail : psychologie du travail et des organisations, psychologie sociale et psychosociologie, psychanalyse, psychopathologie et psychiatrie, ergonomie, sociologie du travail et des organisations, médecine du travail, droit du travail et de la sécurité sociale, sciences de gestion, philosophie... Y sont détaillés les principaux concepts, notions, approches, méthodes, théories, outils, études, etc., ayant cours dans l'étude des risques psychosociaux, mais aussi certaines professions emblématiques (infirmières,...

  19. Le vernis des apparences

    Directory of Open Access Journals (Sweden)

    Grazia Nicosia

    2010-04-01

    Full Text Available Le but de cet article est de comprendre l’incidence sémiotique du nettoyage d’un tableau ainsi que la résultante cognitive induite sur l’observateur. Cette étude confronte l’analyse des phénomènes visuels engendrés par le jaunissement du vernis et son retrait, à des entretiens réalisés à dessein. Le retrait d’un vernis jauni change considérablement l’image. L’heure, le climat, la saison et l’activité même des personnages s’en trouvent ainsi modifié. La patine peut être perçue, soit comme un obstacle à l’exploration, soit pour ceux qui l’apprécient, comme le medium d’une relation plus intime entre l’œuvre et l’observateur.The purpose of this article is to understand the semiotic impact of the cleaning of a painting and the cognitive effects induced on the observer. This study analyses conjointly the visual phenomenon generated by yellowing varnish and its removal and controlled interviews of observers.The removal of yellowing varnish modifies considerably the perception of the picture. Daytime, climate, season and characters activities are modified. The patina may be perceived either as an obstacle to the painting exploration, or, for those who appreciate it, as a medium for a closer relationship between the painting and the observer.

  20. Harmonische Reduktion des linken Ventrikels

    OpenAIRE

    Atila, M. (Mehmet)

    2005-01-01

    In der vorliegenden Arbeit wurde die harmonische Reduktion des linken Ventrikels am Modell des ausgewachsenen Hausschweins, unter Verwendung von Saugkappen variabler Größe untersucht. In 10 Schweinen mit Herzen normaler Größe und Funktion wurde eine Saugkappe, in Größe und Form an das abzufaltende Wandsegment angepasst, auf die epikardiale Oberfläche des schlagenden Herzens gesetzt. Wir führten Messungen der linksventrik. und der pulmonalart. Drücke, des ventrikulären Durchmessers und der Her...

  1. Contribution to the study of the reaction p + {sup 11}B = 3 {alpha} by the coincidence method; Contribution a l'etude de la reaction p + {sup 11}B = 3 {alpha} par la methode des coincidences

    Energy Technology Data Exchange (ETDEWEB)

    Laugier, J Ph [Commissariat a l' Energie Atomique, Bruyeres-le-Chatel (France). Centre d' Etudes

    1969-07-01

    bore autoportees; refroidissement des detecteurs a semi-conducteur employes; enregistrement de 3 parametres pour definir chaque evenement = les energies des deux particules detectees et le temps qui separe les instants de detection de ces particules; enregistrement des informations: les informations sont d'une part inscrites sur bande magnetique, d'autre part traitees partiellement a l'aide d'un ordinateur CAE 510 en ligne avec l'experience. L'exploitation complete des donnees experimentales s'effectue en temps differe sur l'ordinateur CAE 510. (auteur)

  2. Possibilities of gas-phase radio-chromatography application to permanent-gas analysis; Possibilites de la radiochromatographie en phase gazeuse applications a l'analyse des gaz permanents

    Energy Technology Data Exchange (ETDEWEB)

    Dupuis, M C; Charrier, G; Alba, C; Massimino, D [Commissariat a l' Energie Atomique, Bruyeres-le-Chatel (France). Centre d' Etudes

    1970-07-01

    The gas-phase radio-chromatography technique has been applied to the rapid analysis of permanent gases (H{sub 2}, O{sub 2}, N{sub 2}, A, Kr, Xe, CO, CH{sub 4}) labelled with radioactive indicators ({sup 3}H, {sup 37}A, {sup 85}Kr, {sup 133}Xe). After calibration, the components of such a mixture can be identified and their concentrations measured in less than two hours, using a sample volume of from 0.1 to 10 cm{sup 3}. The minimum detectable activity is of the order of 10{sup -4} {mu}C for each radioactive isotope. The measurements are reproducible to about 2 to 3 per cent. This work has been mainly concerned with the influence of parameters affecting the response of the radioactivity detector (ionization chamber or gas flow proportional counter). The method has very numerous applications both theoretically, for the study of chromatographic phenomena under ideal conditions (infinitesimal concentrations made possible by the use of radioactive tracers), and practically, for rapid and accurate radiochemical analysis of radioactive gas mixtures. (authors) [French] La technique de radiochromatographie en phase gazeuse est appliquee a l'analyse rapide de gaz permanents (H{sub 2}, O{sub 2}, N{sub 2}, A, Kr, Xe, CO, CH{sub 4}) marques par des indicateurs radioactifs ({sup 3}H, {sup 37}A, {sup 85}Kr, {sup 133}Xe). Apres etalonnage, l'identification et la mesure des concentrations des constituants d'un tel melange requierent moins de deux heures, sur un volume d'echantillon de 0.1 a 10 cm{sup 3}. L'activite minimum detectable est de l'ordre de 10{sup -4} {mu}C pour chaque isotope radioactif. La reproductibilite des mesures est de l'ordre de 2 a 3 pour cent. L'etude porte principalement sur l'influence des parametres affectant la reponse du detecteur de radioactivite (chambre d'ionisation, ou compteur proportionnel a circulation). La methode est extremement fertile en applications tant sur le plan theorique pour l'etude du phenomene chromatographique dans les conditions

  3. Possibilities of gas-phase radio-chromatography application to permanent-gas analysis; Possibilites de la radiochromatographie en phase gazeuse applications a l'analyse des gaz permanents

    Energy Technology Data Exchange (ETDEWEB)

    Dupuis, M.C.; Charrier, G.; Alba, C.; Massimino, D. [Commissariat a l' Energie Atomique, Bruyeres-le-Chatel (France). Centre d' Etudes

    1970-07-01

    The gas-phase radio-chromatography technique has been applied to the rapid analysis of permanent gases (H{sub 2}, O{sub 2}, N{sub 2}, A, Kr, Xe, CO, CH{sub 4}) labelled with radioactive indicators ({sup 3}H, {sup 37}A, {sup 85}Kr, {sup 133}Xe). After calibration, the components of such a mixture can be identified and their concentrations measured in less than two hours, using a sample volume of from 0.1 to 10 cm{sup 3}. The minimum detectable activity is of the order of 10{sup -4} {mu}C for each radioactive isotope. The measurements are reproducible to about 2 to 3 per cent. This work has been mainly concerned with the influence of parameters affecting the response of the radioactivity detector (ionization chamber or gas flow proportional counter). The method has very numerous applications both theoretically, for the study of chromatographic phenomena under ideal conditions (infinitesimal concentrations made possible by the use of radioactive tracers), and practically, for rapid and accurate radiochemical analysis of radioactive gas mixtures. (authors) [French] La technique de radiochromatographie en phase gazeuse est appliquee a l'analyse rapide de gaz permanents (H{sub 2}, O{sub 2}, N{sub 2}, A, Kr, Xe, CO, CH{sub 4}) marques par des indicateurs radioactifs ({sup 3}H, {sup 37}A, {sup 85}Kr, {sup 133}Xe). Apres etalonnage, l'identification et la mesure des concentrations des constituants d'un tel melange requierent moins de deux heures, sur un volume d'echantillon de 0.1 a 10 cm{sup 3}. L'activite minimum detectable est de l'ordre de 10{sup -4} {mu}C pour chaque isotope radioactif. La reproductibilite des mesures est de l'ordre de 2 a 3 pour cent. L'etude porte principalement sur l'influence des parametres affectant la reponse du detecteur de radioactivite (chambre d'ionisation, ou compteur proportionnel a circulation). La methode est extremement fertile en applications tant sur le plan theorique pour l

  4. La recherche en action : des solutions locales, des effets durables ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    15 déc. 2010 ... Le Centre de recherches pour le développement international (CRDI) appuie la production et l'application de connaissances qui améliorent de façon notable la situation des habitants des pays en développement.

  5. Analyse des caractéristiques structurelles et des performances ...

    African Journals Online (AJOL)

    SARAH

    28 févr. 2014 ... performances technico-économiques de la riziculture irriguée en Côte d' .... en nous basant sur les prix des intrants et des produits en vigueur au cours ..... la recherche et de la vulgarisation et le transfert de technologies ; (2) ...

  6. Evaluation des pratiques de gestion des adventices en riziculture

    African Journals Online (AJOL)

    Les résultats ont montré que les méthodes de gestion de l'enherbement ont .... Le contrôle des adventices en riziculture irriguée a principalement .... mesurer la hauteur des plantes et la longueur ..... Performance agronomique du Sys- tème de ...

  7. Diversification des moyens de subsistance des petits producteurs de ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    L'économie du Malawi repose essentiellement sur la culture du tabac, qui représente plus de 70 % des revenus d'exportation. Pour 60 % des 100 000 membres de la National Smallholder Farmers' Association of Malawi (NASFAM), le tabac est la seule et unique source de revenus. Les cultivateurs de tabac, au Malawi ...

  8. Culture du bambou : diversification des moyens de subsistance des ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Culture du bambou : diversification des moyens de subsistance des petits producteurs de tabac du sud de la province de Nyanza, au Kenya - phase II. Au cours de la première phase du projet (projet no 103765), les chercheurs ont effectué une analyse de marché pour le bambou et les produits du bambou, comparé les ...

  9. Roles et taches des accompagnateurs des patients hospitalises ...

    African Journals Online (AJOL)

    Roles et taches des accompagnateurs des patients hospitalises dans le service de pneumo-phtysiologie au Centre Hospitalier Universitaire Yalgado Ouedraogo de ... Logistical support represented by material support, drug supply, cleaning of premises, and littering occupied respectively 100%, 91%, 42% and 73%.

  10. Theoretical and Applied Aspects of Radiation D-Values for Spores of Clostridium Botulinum; Aspects Theoriques et Pratiques des Valeurs D de Rayonnement Appliquees aux Spores de Clostridium Botulinum; Teoreticheskie i prikladnye aspekty koehffitsienta izlucheniya odlya spor Clostridium Botulinum; Aspectos Teoricos y Practicos de los Valores D para Esporas del Clostridium Botulinum

    Energy Technology Data Exchange (ETDEWEB)

    Grecz, N. [Biophysics Laboratory, Illinois Institute Of Technology, Chicago, IL (United States)

    1966-11-15

    Spores of C. botulinum have been found to have equal or greater resistance to ionizing radiations than spores of other non-toxic food spoilage organisms. For this reason the microbiological processing standards for radiation preservation of foods were invariably related to radiation resistance of spores of C. bonilinum. The index of radioresistance is the D{sub 10}-value defined as the dose necessary to inactivate one log cycle (90%) of a given spore population and 12 XD has been arbitrarily defined as the safe radiation preservation dose for food products. Extensive data from the author's laboratory revealed that (a) the D{sub 10} -value of a particular strain depended on temperature, medium and size of spore inoculum and (b) substantially different D-values may be obtained depending on the method of calculation and unknown variations from experiment to experiment. This information provides a basis for reappraisal of the 12D concept. The temperature during radiation can be shown to influence indirect effects of radicals: (a) their formation, (b) chemical reactivity, (c) extent of annealment and (d) diffusion, especially during liquid-solid transition of the medium around 0 Degree-Sign C. A combination of these temperature-dependent effects explains why spores are most sensitive when irradiated at 0 Degree-Sign C as compared with higher or lower temperatures. In addition to its effect on radicals, the temperature also affects the essential targets (DNA) directly. This involves the vibrational state as well as the extent of hydration of the DNA molecules. The apparent hydration of DNA is related to the range of action of indirect effects which can be calculated for C. botulinum 33A to add an additional 30A to the radius of DNA (10.5A), i.e. almost triple the effect of radiation. This change in radiosensitive volume is reflected by a corresponding change in D{sub 37} value from 1.6 x 10{sup 5} rad for the dry spore to 6.6 x 10{sup 4} rad for the wet spore. The

  11. The neutronic method for measuring soil moisture; La methode neutronique de mesure de l'humidite des sols

    Energy Technology Data Exchange (ETDEWEB)

    Couchat, Ph [Commissariat a l' Energie Atomique, Cadarache (France). Centre d' Etudes Nucleaires

    1967-07-01

    The three group diffusion theory being chosen as the most adequate method for determining the response of the neutron soil moisture probe, a mathematical model is worked out using a numerical calculation programme with Fortran IV coding. This model is fitted to the experimental conditions by determining the effect of different parameters of measuring device: channel, fast neutron source, detector, as also the soil behaviour under neutron irradiation: absorbers, chemical binding of elements. The adequacy of the model is tested by fitting a line through the image points corresponding to the couples of experimental and theoretical values, for seven media having different chemical composition: sand, alumina, line stone, dolomite, kaolin, sandy loam, calcareous clay. The model chosen gives a good expression of the dry density influence and allows {alpha}, {beta}, {gamma} and {delta} constants to be calculated for a definite soil according to the following relation which gives the count rate of the soil moisture probe: N = ({alpha} {rho}{sub s} +{beta}) H{sub v} +{gamma} {rho}{sub s} + {delta}. (author) [French] La theorie a trois groupes etant choisie comme le moyen le plus adequat pour determiner la reponse de l'humidimetre, une mise en forme d'un modele mathematique est effectuee grace a un programme de calcul numerique ecrit en code Fortran IV. Cette representation est adaptee a l'experience par l'etude de l'influence de parametres du systeme de mesure: tubage, source, detecteur, et du comportement du sol vis-a-vis des neutrons: presence d'absorbeurs, liaison chimique des elements. La validite du modele est testee par ajustement d'une droite aux points images des couples de valeurs experimentales et theoriques, ceci pour sept milieux distincts definis par leur composition chimique: sable, alumine, calcaire, dolomie, kaolin, limon sableux, argile calcaire. Le modele prevoit, bien l'influence de la densite seche et permet de calculer pour un sol donne les constantes

  12. Methods of Particle Detection in Free Neutron Decay; Methode de detection des particules dans une desintegration de neutrons libres; Metod obnaruzheniya chastits pri raspade svobodnogo nejtrona; Metodo para la deteccion de particulas en la desintegracion de neutrones libres

    Energy Technology Data Exchange (ETDEWEB)

    Novey, T B [Argonne National Laboratory, Lemont, IL (United States)

    1960-06-15

    A number of experimental studies have recently been completed by the Argonne Group on the decay of polarized neutrons in order to elucidate the structure of the weak nuclear interaction. These studies have taken the form of the measurement of the. angular distributions of electrons and protons with respect to the spin direction of the decaying free neutrons. The basic components of the apparatus which will be discussed are: 1. The one-meter iron-cobalt mirror which selects a beam of highly polarized neutrons and the methods for determination of the polarization. 2. The electron detector comprising a 10 cm diameter, 6 mm thick mosaic of anthracene crystals, and its light pipe system. 3. The proton detector, a 14-stage electron multiplier system, the first stage with a 15x15 cm opening, tapering in four stages to a standard 10-stage multiplier structure, and its entrance baffles for angular resolution. 4. The electronic system which selects pulses from the detectors having the proper time sequence, relative time-delay and pulse-height to allow indentification of a neutron decay. (author) [French] Le groupe Argonne a termine recemment des etudes experimentales sur la desintegration des neutrons polarises, en vue de mettre en lumiere le processus de l'interaction nucleaire faible. Ces etudes consistaient a mesurer les distributions angulaires d'electrons et de protons par rapport a la direction du spin des neutrons libres en voie de desintegration. Les principaux elements de l'appareillage qui sera decrit sont: 1. Le miroir de ferro-cobalt d'un metre, qui isole un faisceau de neutrons hautement polarises, ainsi que les methodes permettant de determiner la polarisation. 2. Le detecteur electronique qui comprend une mosaique de 10 cm de diametre et de 6 mm d'epaisseur en cristaux d'anthracene, et son systeme selectif. 3. Le detecteur de protons, un systeme multiplicateur electronique a 14 etages, le premier ayant une ouverture de 15x15 cm se retrecissant en 4 etages pour

  13. On some uses of the recording op fission fragments occurring in insulators; Sur quelques utilisations de l'enregistrement des fragments de fission dans les isolants

    Energy Technology Data Exchange (ETDEWEB)

    Mory, J [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1965-07-01

    thermiques: on peut mesurer des flux integres s'etendant de 10{sup 3} a 10{sup 21} n/cm{sup 2}, suivant la methode utilisee; - dosimetrie de neutrons rapides: en utilisant des sources de fragments de fission a seuil, on peut facilement mesurer des doses d'interet biologique de l'ordre du rem; - dosage d'impuretes fissiles en tres faible concentration: on peut determiner des concentrations atomiques de l'ordre de 10{sup 9}, limite jamais atteinte par les procedes usuels; - etude des elements fissiles contenus dans les poussieres atmospheriques. On donne ensuite brievement les resultats d'un essai d'automatisation du comptage des traces par mesure de la resistivite electrique de la membrane irradiee. On expose enfin les avantages et les inconvenients de ces detecteurs solides, notamment par rapport aux emulsions nucleaires dont les utilisations sont a peu pres identiques. (auteur)

  14. Utilisation sans risque des eaux usées, des excréta et des eaux ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Les responsables de ce projet piloteront l'application et l'adaptation des principes directeurs relatifs à l'utilisation sans risque des eaux usées, des excreta et des eaux grises en agriculture et en aquaculture (Guidelines for the Safe Use of Wastewater, Excreta and Greywater in Agriculture and Aquaculture), que ...

  15. Adaptive response to ionizing radiation in normal human skin fibroblasts. Enhancement of DNA repair rate and modulation of gene expression. Reponse adaptative au rayonnement ionisant des fibroblastes de peau humaine. Augmentation de la vitesse de reparation de l'ADN et variation de l'expression des genes

    Energy Technology Data Exchange (ETDEWEB)

    Toledo, S.M. de; Mitchel, R.E.J. (Atomic Energy of Canada Ltd., Chalk River, ON (Canada). Chalk River Nuclear Labs.); Azzam, E. (Atomic Energy of Canada Ltd., Chalk River, ON (Canada). Chalk River Nuclear Labs. Ottawa Univ., ON (Canada). Dept. of Biology); Raaphorst, G.P. (Ottawa Univ., ON (Canada). Dept. of Biology)

    Low doses and dose rates of ionizing radiation enhance the rate of DNA repair in human fibroblasts and protect the cells against radiation-induced micronucleus formation. Chronic exposures reduce the mRNA levels of the genes topoisomerase II and FACC-1 (Fanconi's anemia, group C). (authors). 11 refs., 1 tab., 2 figs.

  16. Decree no. 2003-296 on the 31 of march 2003 relative to the workers protection against the ionizing radiations; Decret no. 2003-296 du 31 mars 2003 relatif a la protection des travailleurs contre les dangers des rayonnements ionisants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-07-01

    The different conditions modifying the Labour code in relation with the radiation protection of workers are exposed in detail, from the occupational exposure in normal conditions, the organisation of radiation protection, the abnormal working conditions until the medical examinations and medical follow up. (N.C.)

  17. Copolymerization of Ethylene Induced by Cobalt-60 Gamma Radiation; Copolymerisation de l'ethylene induite par des rayons gamma du cobalt-60; Sopolimerizatsiya ehtilena pod dejstviem gamma-izlucheniya ot istochnika ks'yali-60; Copolimerizacion del etileno inducida por las radiaciones gamma del cobalto-60

    Energy Technology Data Exchange (ETDEWEB)

    Steinberg, M.; Colombo, P. [Brookhaven National Laboratory, Long Island, NY (United States)

    1963-11-15

    The gamma radiation initiated copolymerization of ethylene with a number of different monomers was studied at 20{sup o}C and initial pressures up to 680 atm. The experiments were conducted statically in two-phase systems with the exception of the ethylene-carbon monoxide system. Isolation of the copolymers was effected by solvent extraction and fractional precipitation techniques. Infra-red spectroscopy was used for identification. The composition was determined by elemental analysis. A partial evaluation of some of the reaction products including crystalline melting points, densities, solubility characteristics, and molecular weights are given. Evidence of ethylene copolymerization was established with each of the following monomers: styrene, methyl methacrylate, vinyl acetate, acrylonitrile, allyl acetate, isobutylene, chlorotrifluoroethylene, trans 2-butene, methyl acrylate, isoprene, propylene, vinyl chloride, 1-butene, cis 2-butene, carbon monoxide, vinyl pyrrolidone, methyl vinyl ketone, and divinyl benzene. The experimental data obtained in the study of the ethylene-carbon monoxide system were found to obey a linear form of the copolymer composition equation. The ratio of specific rate constants for carbon monoxide and ethylene ({alpha}) was found to have a value of 22.0, indicating that carbon monoxide as a monomer, is activated to the extent that it adds 22 times as fast as an ethylene monomer to an ethylene free-radical chain end. Explosive decomposition was observed to occur during irradiation of ethylene arid chlorotrifluoroethylene under certain irradiation conditions. There is an indication that a threshold radiation intensity exists which induces this violent reaction. The unique advantage of cobalt-60 gamma radiation is that it can be used to induce and control ethylene copolymerization reactions at low temperatures. (author) [French] La copolymerisation de l'ethylene avec divers monomeres provoquee avec des rayons gamma a ete etudiee a 20{sup o

  18. The nuclear core of sun: theoretical perspectives and characterization of the scientific performances of the GOLF / SOHO experiment detector; La region nucleaire du soleil: perspectives theoriques et caracterisation des performances scientifiques du detecteur de l`experience GOLF / SOHO

    Energy Technology Data Exchange (ETDEWEB)

    Dzitko, H

    1995-06-23

    The subject of this thesis is the nuclear core of the sun. The first part is theoretical and concerns neutrino flux predictions. A precise description of the solar plasma is necessary to predict boron, beryllium and CNO cycle neutrinos. We treat here the nuclear reaction rates. They are mainly determined by the cross sections and the enhancement factors due to plasma particles, the co-called screening factors. We have discussed the various possible formalisms that could be used in stellar evolution and performed direct calculations of screened cross sections. We concluded that the screening prescriptions which have been used so far in stellar evolution should be replaced by the Mitler formalism. Next, we examine the cross section uncertainties and we show that it is possible to get a better agreement between theory and experiment. Discrepancies between the gallium experiments and the calculations suggest that we should go beyond the classical solar model. This has motivated our study on possible magnetic fields deeply buried in the solar core. We discuss here the influence of a magnetic pressure perturbation on solar evolution. In the experimental part of this work, we deal with the GOLF experiment, one of the three helio-seismological experiments on board the space probe SOHO. The purpose of this instrument is the study of the global oscillation modes in the frequency range 10{sup -7} to 6 10{sup -3} Hz with a sensitivity for frequencies higher than 2 10{sup -4} Hz of about 1 mm/s over 20 days of continuous integration at counting rates of 12 10{sup 6} cs/s. One part of this work was devoted to the precise characterization of the photomultipliers and their associated electronics in order to select them according to their intrinsic performances. This step was followed by long duration tests of three weeks simulating as well as possible the flight conditions. We show that the detection chain effectively meets the stability requirements of around 10{sup -7} by velocity measurement. (Abstract Truncated)

  19. Jet measurements in ATLAS Detector for making evident the deconfinement in heavy ion collisions; Mesure des jets dans le detecteur ATLAS en vue de la mise en evidence du deconfinement dans les collisions d`ions lourds

    Energy Technology Data Exchange (ETDEWEB)

    Poirot, S. [Ecole Doctorale des Sciences Fondamentales, Clermont-Ferrand-2 Univ., 63 - Aubiere (France). U.F.R. de Recherche Scientifique et Technique

    1996-12-13

    In this thesis the two kinds of works encountered in the preparation of a big experiment at LHC are considered: R and D on the optimization of the light collection from the hadronic tile calorimeter of ATLAS, using new photomultipliers (PM), and physical simulations of the search for nuclear matter deconfinement in heavy ion collisions. The interest of using LHC is to obtain thermodynamical conditions better than those offered for the present or future experiments, by the SPS and RHIC accelerators, respectively. ATLAS is a general purpose p-p experiment that offers the additional possibility of studying the behaviour of heavy quarkonia and jets as deconfinement external probes, in terms of the global variables characterizing the collision geometry and thermodynamics. The definition of a proper strategy for ATLAS requires a comparison with the other experiments (ALICE and CMS) at LHC. It is shown that the search of the jet quenching at a reduced luminosity is the most promising approach for ATLAS. The experiment is described, and in particular the hadronic tile calorimeter, especially designed for the jet studies. The produced light is readout by a new PM the optimisation of which is described in order to design the PM blocks containing the light mixing, the PM itself, the divider bridge and associated electronics. Special attention is paid to the PM gains, the optimisation of the light guides and magnetic shielding. That is retained by ATLAS as the base line solution. (author) 68 refs.

  20. LEP1 measurement of heavy quark forward-backward asymmetries with Opal detector; Mesure de l`asymetrie avant-arriere des quarks lourds a LEP1 avec le detecteur Opal

    Energy Technology Data Exchange (ETDEWEB)

    Lafoux, H

    1996-04-30

    Using all data collected by OPAL during the first phase of LEP operation, called LEP1, we have measured the b and c quark forward-backward asymmetries on and around the Z{sup 0} peak. The measurement, which is based on prompt leptons produced in semileptonic decays of heavy quarks, has been optimized using artificial neural networks whenever necessary, that is whenever the problem to solve implied taking into account simultaneously a large number of parameters. Our results are compatible with other LEP measurements and with the Standard Model predictions for a top quark of 174{+-}31 GeV/c{open_square} and a Higgs boson mass between 60 and 1000 GeV/c{open_square}. (author). 159 refs., 88 figs., 37 tabs.

  1. The use of production management techniques in the construction of a large high energy physics detector; L'utilisation des techniques de gestion de production dans la construction d'un grand detecteur de physique

    Energy Technology Data Exchange (ETDEWEB)

    Murray, St

    2000-11-10

    The lifetime of a particle detector can be divided into 4 periods: designing, engineering drawing, manufacturing and operation-maintenance. Some computer systems and software deal with the management of the designing and engineering drawing, others deal with data acquisition and processing, but no systems exist for the manufacturing phase where particular solutions are proposed every time a problem arises. New-generation detectors that are to be set for the experiments at the future LHC (large hadron collider) will be 10 times more complex than the today detectors and be expected to operate for around 15 years. This complexity associated with a longer operating life implies an efficient and evolutive information system to handle the manufacturing phase. In this work the author has applied the techniques of production management to the manufacturing phase of the compact muon solenoid (CMS), he assigned 3 purposes: 1) to propose a modelling of the description of each component and of its manufacturing process, 2) to develop a graphic software allowing to view the assembling of the different components of the detector, and 3) to evaluate the resource of production of such a device, it means to balance demand with capacity and to optimize the use of production means. (A.C.)

  2. Development and validation of HELLAZ1 detector, contribution to the project HELLAZ concerning the detection of solar neutrinos; Developpement et mise au point du detecteur HELLAZ1: elaboration du projet HELLAZ pour la detection des neutrinos solaires

    Energy Technology Data Exchange (ETDEWEB)

    Gagliardi, N

    2001-09-01

    The HELLAZ project is dedicated to the measurement of low energy solar neutrinos, this neutrino detection is based on the measurement of the characteristics of all the ionization electrons produced by the recoil of the electron with which the solar neutrino has collided. The detector is made of a tank full of gaseous helium whose conditions of temperature and pressure (77 K and 5 bar) are important to assure a sufficient statistic. 11 events a day are expected to be detected. In this work we present the preliminary results obtained on the first prototype (HELLAZ0) that has allowed us to test 2 types of chambers: multiwire proportional chamber (MWPC) and a micro gas chamber combined to a gas electron multiplier (MGC+GEM). A new prototype (HELLAZ1) has been designed, its aim is to measure an elementary track of only 2 ionization electrons and to test 2 new chambers: micro gas wire chamber (MGWC) and Micromegas. The first chapter deals with the sun, solar neutrinos, and the neutrino characteristics that are expected from the sun standard model. The second chapter is dedicated to the various experiments of solar neutrino detection and to their experimental result disagreement. The HELLAZ project is described in the third chapter. The fourth chapter presents the different experimental constraints, particularly the processing of the background noise and the counting of each electron of the ionization cloud. In the last chapter HELLAZ0 and HELLAZ1 projects are described and we show that microstructure-type chambers are the best suitable for this kind of detection. (A.C.)

  3. Study of the decays: B {yields} {eta}{sub c} K with the detector BaBar; Etude des desintegrations B {yields} {eta}{sub c} K avec le detecteur BaBar

    Energy Technology Data Exchange (ETDEWEB)

    Langer, M

    2003-04-01

    This thesis presents a study of the exclusive decays B{sup {+-}} {yields} {eta}{sub c}K{sup {+-}} and B{sup 0} {yields} {eta}{sub c}K{sub S}{sup 0} with {eta}{sub c} {yields} K{sub S}{sup 0}K{sup {+-}}{pi}{sup {+-}}, {eta}{sub c} {yields} K{sup +}K{sup -}{pi}{sup 0} and {eta}{sub c} {yields} K{sup +}K{sup -}K{sup +}K{sup -}, and the measurement of their branching ratios. We use 20.7 fb{sup -1} of data collected by the experiment BABAR at the {gamma}(4S) resonance between October 1999 and October 2000. These data correspond to 23 million BB-bar pairs. In the decays {eta}{sub c} {yields} K{sub S}{sup 0}K{sup {+-}}{pi}{sup {+-}} and {eta}{sub c} {yields} K{sup +}K{sup -}{pi}{sup 0} the observed signals are statistically significant; they allow to measure the branching ratios. Upper limits are set, in the channels with {eta}{sub c} {yields} K{sup +}K{sup -}K{sup +}K{sup -}: B(B{sup +}{yields}{eta}{sub c}K{sup +}) * B({eta}{sub c}{yields}K{sup +}K{sup -}K{sup +}K{sup -}) < 5,6 x 10{sup -6} (90% confidence level); B(B{sup +}{yields}{eta}{sub c}K{sup +}) * B({eta}{sub c}{yields}K{sup 0}K{sup -}{pi}{sup +}+c.c.) (52,8{+-}7,9{+-}7,3) x 10{sup -6}; B(B{sup +}{yields}{eta}{sub c}K{sup +}) * B({eta}{sub c}{yields}K{sup +}K{sup -}{pi}{sup 0}) (15,5{+-}3,6{+-}2,5) x 10{sup -6}; B(B{sup 0}{yields}{eta}{sub c}K{sup 0}) * B({eta}{sub c}{yields} K{sup +}K{sup -}K{sup +}K{sup -}) < 2,3 x 10{sup -6} (90% confidence level); B(B{sup 0}{yields}{eta}{sub c}K{sup 0}) * B({eta}{sub c}{yields}K{sup 0}K{sup -}{pi}{sup +}+c.c.) (36,8{+-}11,6{+-}6,0)x 10{sup -6}; B(B{sup 0}{yields}{eta}{sub c}K{sup 0}) * B({eta}{sub c}{yields} K{sup +}K{sup -}{pi}{sup 0}) = (11,3{+-}5,1{+-}2,4) x 10{sup -6}; where the first error is statistical and the second systematic. The average of the branching ratio of {eta}{sub c} {yields}K{sub S}{sup 0}K{sup {+-}}{pi}{sup {+-}} and {eta}{sub c} {yields} K{sup +}K{sup -}{pi}{sup 0} for the channels B{sup {+-}} {yields} {eta}{sub c}K{sup {+-}} and B{sup 0} {yields} {eta}{sub c}K{sub S}{sup 0}, taking into account the common systematical errors, leads to: B(B{sup +}{yields}{eta}{sub c}K{sup +}) * B({eta}{sub c}{yields}KK-bar{pi}) = (82,5{+-}10,4{+-}8,3) x 10{sup -6} and B(B{sup 0}{yields}{eta}{sub c}K{sup 0}) * B({eta}{sub c}{yields} KK-bar{pi}) (58,1{+-}15,2{+-}6,3) x 10{sup -6}. The ratios R{sub K} {identical_to} {gamma}(B {yields}{eta}{sub c}K)/{gamma}(B {yields}J/{psi}K) have been determined to R{sub K}(B{sup +}) 1,48 {+-} 0,19 {+-} 0,17 {+-} 0,46 and R{sub K}(B{sup 0}) = 1,24 {+-} 0,33 {+-} 0,16 {+-} 0,38. These measurements are dominated by the uncertainty on the world average of the {eta}{sub c} {yields} KK-bar{pi} branching ratio (third error). Our results are compatible with the theoretical predictions, which cover a large range; it is not possible to obtain stronger conclusions. (author)

  4. Study of the physical processes involved in the operating mode of the micro-strips gas detector Micromegas; Analyse des phenomenes physiques lies au fonctionnement du detecteur gazeux a micropistes micromegas

    Energy Technology Data Exchange (ETDEWEB)

    Barouch, G

    2001-04-01

    Micromegas is a micro-strip gaseous detector invented in 1996. It consists of two volumes of gas separated by a micro-mesh. The first volume of gas, 3 mm thick, is used to liberate ionization electrons from the incident charged particle. In the second volume, only 100 {mu}m thick, an avalanche phenomenon amplifies the electrons produced in the first volume. Strips printed on an insulating substrate collect the electrons from the avalanche. The geometrical configuration of Micromegas showed many advantages. The short anode-cathode distance combined with a high granularity provide high rate capabilities due to a fast collection of ions produced during the avalanche development. Moreover, the possibility to localize the avalanche with strips printed about every hundreds of micrometers allows to measure the position of the incident particle with a good resolution. In this work, experimental tests of Micromegas are presented along with detailed Monte Carlo simulations used to understand and optimize the detector's performances. The prototypes were tested several times at the PS accelerator at CERN. The analysis of the date showed a stable and efficient behavior of Micromegas combined with an excellent space resolution. In fact, spatial resolutions of less than 15 {mu}m were obtained. In parallel with the in-beam tests, several simulations have been developed in order to gain a better understanding of the detector's response. (author)

  5. MUST, a set of strip detectors for studying radioactive beams induced reactions; MUST, un ensemble de detecteurs a pistes pour l`etude des reactions induites par faisceaux radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    Blumenfeld, Y.; Barbier, A.; Beaumel, D.; Charlet, D.; Clavelin, J.F.; Douet, R.; Engrand, M.; Lebon, S.; Lelong, P.; Lesage, A.; Leven, V.; Lhenry, I.; Marechal, F.; Petizon, L.; Pouthas, J.; Richard, A.; Rougier, D.; Soulet, C.; Suomijaervi, T.; Volkov, P.; Voltolini, G. [Paris-11 Univ., 91 - Orsay (France). Inst. de Physique Nucleaire; Auger, F.; Ottini, S.; Alamanos, N. [CEA Centre d`Etudes de Saclay, 91 - Gif-sur-Yvette (France). Dept. d`Astrophysique, de la Physique des Particules, de la Physique Nucleaire et de l`Instrumentation Associee; Sauvestre, J.E.; Bonnereau, B.; Champion, L.; Delbourgo-Salvador, P.; Ethvignot, T.; Szmigiel, M. [CEA Centre d`Etudes de Bruyeres-le-Chatel, 91 (France)

    1996-12-31

    This report states the specificity of light particles elastic scattering, and the need of detecting recoil protons to improve angular resolution. Then the development of a specific MUST strip detector is detailed: 60 strips detectors with Si O sub 2 dielectric, that yield 500 ps time resolution, and Si (Li) detectors following next. A versatile data acquisition system has been developed too, with CAMAC interface to suit to any experimental plant. (D.L.). 27 refs.

  6. Measurement of Bose-Einstein correlations in the decays of W boson pairs by the ALEPH detector at LEP; Mesure des correlations de Bose-Einstein dans les desintegrations de paires de Bosons W avec le detecteur ALEPH au LEP

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Franck [Laboratoire d' Annecy-Le-Vieux de Physique des Particules, Grenoble-1 Univ., 74 Annecy (France)

    1999-04-16

    The measurement of the W boson mass is a key issue of LEP2. In the W{sup +}W{sup -} {yields} q{sub 1}q{sub 2}-bar q{sub 3}q{sub 4}-bar channel, a large systematic error comes from Bose-Einstein correlations, which could induce a non-independent fragmentation of the two W. This thesis deals with the measurements of these correlations in W boson pair decays. We will focus on the measurement of such correlations between points from different decaying W. The standard model theory and the ALEPH experiment are described in the two first chapters. The analysis requires a selection of W{sup +}W{sup -} {yields} q{sub 1}q{sub 2}-bar l{nu}{sub l} events, which is presented in chapter three. The W{sup +}W{sup -} {yields} q{sub 1}q{sub 2}-bar q{sub 3}q{sub 4}-bar and W{sup +}W{sup -} {yields} q{sub 1}q{sub 2}-bar {tau}{nu} event selections are also described in this part. The different phenomenological models of Bose-Einstein correlations are reviewed in chapter four, with their adjustment on the ALEPH data recorded at {radical}s = 91 GeV. The model predictions are compared to results of measurements done in W{sup +}W{sup -} decays observed at energies of collisions of 172, 183 and 189 GeV. Bose-Einstein correlations between pions coming from different W in the W{sup +}W{sup -} {yields} q{sub 1}q{sub 2}-bar q{sub 3}q{sub 4}-bar channel are disfavored by 2.7 standard deviations.

  7. Measurement of W{sup {+-}} boson mass at LEP by means of DELPHI detector; Mesure de la masse des bosons W{sup {+-}} au LEP a l`aide du detecteur DELPHI

    Energy Technology Data Exchange (ETDEWEB)

    Todorova-Nova, Sarka [Universite Louis Pasteur, Institut de Recherches Subatomiques, 67 - Strasbourg (France)

    1998-05-25

    The thesis deals with measurement of the mass of the W boson at LEP2, based on the direct reconstruction of its decay products in the hadronic channel. A set of procedures necessary for the extraction of the W mass from the experimental data collected with the DELPHI detector in 1997 was developed (search of optimal variables for the event selection, development of a special method of kinematical reconstruction). The measured value of the mass was interpreted in the framework of the Standard Model, allowing to constrain the mass of the Higgs boson. A substantial part of the work is devoted to systematic effects due to the interactions between the hadronic decay products of the W bosons (colour reconnection and Bose-Einstein correlations), which may significantly influence the measurement of their mass. (author) 53 refs., 104 figs., 33 tabs.

  8. A search for Higgs bosons h and A of a two doublet model is performed using ALEPH; Recherche des bosons de Higgs neutres d`un modele a deux doublets avec le detecteur ALEPH au LEP

    Energy Technology Data Exchange (ETDEWEB)

    Simion, S.

    1995-04-01

    A search of Higgs bosons h and A of a two-doublet model is performed. We analyse the data collected by ALEPH till 1993, corresponding to a luminosity of 63.4 pb{sup 1} at the Z peak. The {tau}{sup +}{tau}{sup -}q anti q and b anti b b anti b final states are mainly considered. The section criteria are available, thus improving the sensitivity of the analysis. Assuming m{sub h} = m{sub A} = 45 GeV, an upper limit of O.324 pb on the {pi}{sup +}{pi}{sup -}q anti q cross section is derived. The four-b final state selection is based on b-hadron lifetime, using the two-dimensional readout from the vertex detector. We analyse 1.53 million hadronic Z`s without any evidence for a signal (313 events seen, 270+-17 expected from the background, with 24% efficiency for m{sub h} = m{sub A} = 45 GeV.). Searches for the standard Model Higgs boson are interpreted in the framework of a two-doublet model. The decay of the lightest scalar h into a AA pair is also considered. No signal is found and the regions excluded in the (m{sub h} -m{sub A}) and (m{sub A} - tan {beta}) planes of the MSSM are presented. Influence of stop mixing is discussed. Assuming m{sub top} 170 GeV, universal quark masses m{sub Q} = 1 TeV, no stop mixing, and tan {beta} > 1, a 95% lower limit on m{sub A} equal to 45.5 GeV is derived. (authors). 60 refs., 93 figs., 15 tabs.

  9. Search for neutral Higgs bosons in four jets final states with the DELPHI detector; Recherche des bosons de Higgs neutres dans les etats finals a quatre jets avec le detecteur DELPHI

    Energy Technology Data Exchange (ETDEWEB)

    Bizouard, Marie-Anne [Universite de Paris Sud, 91 - Orsay (France)

    1998-05-19

    The search for Higgs bosons is one of the priorities of the LEP200 program developed at CERN. Actually, the Higgs mechanism which predicts the existence of scalar bosons of unknown mass, allows the particles of standard model and its supersymmetric extensions to acquire mass. We have carried out a search for neutral Higgs bosons in the two production channels e{sup +}e{sup -} {yields} Z{sup 0*} {yields} h{sup 0}Z{sup 0} and e{sup +}e{sup -} {yields} Z{sup 0*} {yields} h{sup 0}A{sup 0} resulting from the supersymmetric models if only 4 jets final states are taken into account, which represent 65% and 84%, respectively of the possible modes. A special effort has been undertaken towards the reconstruction of the mass of standard Higgs boson (the h{sup 0}Z{sup 0} channel) and on the improvement in the procedure of the event selection. The studies done on the data recorded by DELPHI from 1995 to 1997 ({radical} = 161, 172 and 183 GeV) allowed excluding with the 95% confidence level a standard Higgs boson lighter then: m{sub h{sup 0}} {>=} 84.4 GeV/c{sup 2} at 95% C.L. (observed limit) and m{sub h{sup 0}} {>=} 86.4 GeV/c{sup 2} at 95% C.L. (expected limit), by including the entirety of Z{sup 0} decay modes. An original analysis developed in this thesis has allowed obtaining an expected limit equal to 86.5 GeV/c{sup 2} by using only the 4 jets final state what constitutes a gain of {approx} 3 GeV/c{sup 2} with respect to the limit evaluated so far in DELPHI. The interpretation in the framework of minimal supersymmetric model (MSSM) of the results obtained in the channel h{sup 0}Z{sup 0} and h{sup 0}A{sup 0} have allowed establishing the following limits for the two Higgs neutral bosons h{sup 0} and A{sup 0}: m{sub h{sup 0}} {>=} 74.4 GeV/c{sup 2} at a 95% C.L. for any tan{beta} and m{sub A{sup 0}} {>=} 75.2 GeV/c{sup 2} at 95% C.L. for any tan{beta}, respectively. Finally, a study of the 4 jets events has been done in the frame of an analysis proposed by ALEPH, following the observation of a 4 jet event excess. The results, we have obtained have not confirmed this excess 118 refs., 107 figs., 39 tabs.

  10. Deeply virtual Compton scattering with the CLAS detector for the study of generalized parton distributions; Diffusion compton profondement virtuelle avec le detecteur CLAS pour une etude des distributions de partons generalisees

    Energy Technology Data Exchange (ETDEWEB)

    Girod, F.X

    2006-12-15

    The structure of the nucleon, among the first fundamental problems in hadronic physics, is the subject of a renewed interest. The lightest baryonic state has historically been described in two complementary approaches: through elastic scattering, measuring form factors which reflect the spatial shape of charge distributions, and through deep inelastic scattering, providing access to parton distribution functions which encode the momentum content carried by the constituents. The recently developed formalism of Generalized Parton Distributions unifies those approaches and provides access to new informations. The cleanest process sensitive to GPDs is the deeply virtual Compton scattering (DVCS) contributing to the ep {yields} ep{gamma} reaction. This work deals with a dedicated experiment accomplished with the CLAS detector, completed with two specific equipments: a lead tungstate calorimeter covering photon detection at small angles, and a superconducting solenoid actively shielding the electromagnetic background. The entire project is covered: from the upgrade of the experimental setup, through the update of the software, data taking and analysis, up to a first comparison of the beam spin asymmetry to model predictions. (author)

  11. Study of final states involving 2 particle jets and missing energy with the DELPHI detector at LEP; Etude des etats finals contenant deux jets de particules et de l'energie manquante avec le detecteur DELPHI a LEP

    Energy Technology Data Exchange (ETDEWEB)

    Ferrer Ribas, E

    2000-05-09

    The observation of the Higgs boson would be of great importance for the understanding of the electroweak symmetry breaking. In the framework of the Minimal Supersymmetric extension of the Standard Model (MSSM), the lightest Higgs boson is neutral and scalar, and its mass must be less than 130 GeV/c{sup 2}. In this thesis, we have studied events characterized by the presence of two particle jets and missing energy. This is a very clear signature of the production of the Higgs boson in association with a Z{sup 0} boson. This production is followed by the decay of the Higgs boson into a bb-bar pair and the Z{sup 0} boson in {nu}{nu}-bar pair. In these studies, it is important to detect all particles in order to achieve a good resolution in energy. For these reasons, we have devoted ourselves to improving DELPHI's hermeticity mainly in the regions located at 40 deg C and 140 deg C. Using the data collected by the DELPHI detector at LEP in 1998 and in 1999 at four different energies in the centre of mass ({radical}s = 189, 196, 200 and 202 GeV), no signal has been observed, allowing us to exclude the Higgs boson at 95 % confidence level up to a mass of: m{sub H} > 98.0 (98.5) GeV/c{sup 2} at 95% C.L. this analysis; m{sub H} > 103.9 (106.3) GeV/c{sup 2} at 95% C.L. DELPHI combined. The values in parentheses show the expected limits and indicate the sensitivity of the analysis. If these results are interpreted in the framework of the MSSM we obtain: m{sub h} > 85.0 (85.3) GeV/c{sup 2} at 95% C.L. Studying the same topology, we have also searched for a Higgs boson decaying into a pair of non detectable particles (Invisible Higgs) in association with a Z{sup 0} boson decaying into a quark/antiquark pair. In this case too, no signal has been observed, which can be translated into a lower limit on the mass of the Higgs boson at 95% confidence level: m{sub h{sub inv}} > 105.5 (105.3) GeV/c{sup 2} at 95% C.L. Finally, we have measured the production cross section of a pair of Z{sup 0} bosons where one decays to a quark/antiquark pair (all flavours) and the other to a pair of neutrinos. The result is in very good agreement with the value predicted by the Standard Model: {sigma}{sup NC02}/{sigma}{sup MS} = 0.94{+-}0.25 this analysis; {sigma}{sup NC02}/{sigma}{sup MS} = 1.04{+-}0.12 DELPHI combined. (author)

  12. Study of the response of a silicon detector irradiated with 1 MeV neutrons; Etude de la reponse d`un detecteur Si irradie par des neutrons de 1 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Roy, P [Montreal Univ., PQ (Canada). Lab. de Physique Nucleaire

    1994-12-31

    The author studied the response of an n-type silicon detector irradiated with 1 MeV neutrons at fluences ranging from 0.26x10{sup 13} to 11.19x10{sup 13} neutrons/cm{sup 2}. The response of the irradiated detector to {sup 241}Am alpha particles was measured. 13 refs., 7 figs.

  13. Development and performance of charged particle detectors applied to the study of heavy ion reactions; Developpement et performances de detecteurs de particules chargees appliques a l`etude des reactions avec ions lourds

    Energy Technology Data Exchange (ETDEWEB)

    Gourde, M; Beaulieu, L; Dore, D; Laforest, R; Pouliot, J; Roy, R; St-Pierre, C [Laval Univ., Quebec City, PQ (Canada). Dept. de Physique

    1994-12-31

    The new type of charged particle detector described comprises a thin layer of plastic scintillator over a much thicker CsI(Tl) crystal, an optical guide, and a photomultiplier. Results obtained at Chalk River Laboratories for the identification of particles with Z = 1-6 from the {sup 12}C + {sup 197}Au reaction are shown. 12 refs., 4 figs.

  14. Study and making of a quick system used for the localisation of X-rays in gaseous detectors; Etude et realisation d`un systeme rapide pour la localisation des rayons X dans les detecteurs gazeux

    Energy Technology Data Exchange (ETDEWEB)

    Chemloul, M.

    1995-02-01

    The project comprises the design of an X-ray detection and position-sensitive system for diffraction experiments at the ERSF synchrotron. The two detectors constructed are gas-filled multiwire proportional chambers. The readout of the ID detector is performed through a 500 ns delay line. In the 2D detector, the centroid of the first coordinate is determined by a RLC line which is a combination of a delay line and the charge division one. This method is a result of an investigation of a delay balance based method. Besides, a parallel readout of the anode wires provides the second coordinate. The signal processing is performed by a common electronics. However, both methods used here require a fast and high resolution time measurement. Hence, a time-to-digital converter was developed and dedicated to the experiment. The data acquisition system is based on a PC board driven by a software developed under Windows system. (author). 39 refs., 80 figs., 2 tabs.

  15. A contribution to the development of the modular neutron detector (DEMON): performance evaluation through measurements and simulations; Contribution a la realisation du detecteur modulaire de neutrons (DEMON): etudes des performances par mesures et simulations

    Energy Technology Data Exchange (ETDEWEB)

    Mouatassim, S

    1994-07-01

    The modular neutron detector is dedicated to the study of heavy ion reaction mechanisms. Monte Carlo simulations are performed for the optimization of the NE213 scintillator cell size and the general geometrical setup for the DEMON multidetector of neutrons with a minimum of cross-talk. Tests are performed with various types of photomultiplier tubes and scintillators. Using high energy neutron beams, more than six different reaction processes were identified with pulse shape discrimination by the charge comparison method. Cross sections were estimated. Light yields of charged particles p, d, t and alpha in the NE213 organic scintillator were analyzed using different theoretical approaches, and the intrinsic efficiency of the DEMON`s modules was measured and compared to Monte Carlo calculations. The DEMON experimental filter was simulated and has been associated with the Gemini physical events generator to study the performance of such a multidetector. Thus, the DEMON response for neutron evaporation of excited nuclei and its influence on energy measurement and temperature determination were studied. The same filter was used to simulate pre- and post-fission emission of neutrons for the fission process of the composite {sup 126}Ba system formed in the {sup 19}F + {sup 107}Ag entrance channel. (from author) 70 figs., 99 refs.

  16. Direction des Publications

    African Journals Online (AJOL)

    Synthese

    mélange pulvérulent de coke et de calcaire. La réduction est assurée par le gaz CO à 1250°C [2]. Le procédé Kawazaki iron powder utilise la calamine comme matière première et aussi CO comme gaz réducteur pour élaborer des poudres de fer. [3]. Un autre procédé plus connu qui fabrique les poudres de fer à partir de la.

  17. Glossaire des sigles

    OpenAIRE

    2015-01-01

    ABM Anti-ballistic missile = Missile antimissile balistique AGM Air-to-ground missile = Missile air-sol AIEA Agence Internationale de l’Energie Atomique ALCM Air-launched cruise missile = Missile de croisière air-sol ANSEA Association des Nations du Sud-Est asiatique ANT* Arme nucléaire tactique ASAT Anti-satellite = Arme antisatellite ASW Anti-submarine warfare = Guerre anti-sous-marine AWACS Airborne warning and control system = Système aérien de contrôle et d’alerte BMD Ballistic missile d...

  18. Absolute measurement of a standard thermal-neutron flux using gold-detector activation; Mesure absolue d'un flux etalon de neutrons thermiques par activation de detecteurs d'or

    Energy Technology Data Exchange (ETDEWEB)

    Paternot, Y [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1967-02-15

    The density of neutrons in a standard stacking is determined between the zero-energy and the cut-off energy of 1 mm thick cadmium unit using a gold detector. Its absolute activity is measured using a 4 {pi} {beta} counter calibrated for 4 {pi} {beta},{gamma} coincidence by counting strongly active sources. The correction factor F due to the disintegration process for the gold is determined experimentally. {phi}{sub 0} = N{sub 0} {sup E}Cd{sub V0} = 6495 {+-} 1.5 per cent n/cm{sup 2}/s. (author) [French] La densite de neutrons dans un empilement etalon est determinee entre l'energie zero et l'energie de coupure d'un boitier de cadmium de 1 mm d'epaisseur au moyen d'un detecteur d'or. Son activite absolue est mesuree a l'aide d'un compteur 4 {pi} {beta} etalonne en coincidence 4 {pi} {beta},{gamma} par comptage de sources fortement actives. Le facteur de correction F d au schema de desintegration de l'or est determine experimentalement. {phi}{sub 0} = N{sub 0} {sup E}Cd{sub V0} = 6495 {+-} 1.5 pour cent n/cm{sup 2}/s. (auteur)

  19. Homogenization of some radiative heat transfer models: application to gas-cooled reactor cores; Homogeneisation de modeles de transferts thermiques et radiatifs: application au coeur des reacteurs a caloporteur gaz

    Energy Technology Data Exchange (ETDEWEB)

    El Ganaoui, K

    2006-09-15

    In the context of homogenization theory we treat some heat transfer problems involving unusual (according to the homogenization) boundary conditions. These problems are defined in a solid periodic perforated domain where two scales (macroscopic and microscopic) are to be taken into account and describe heat transfer by conduction in the solid and by radiation on the wall of each hole. Two kinds of radiation are considered: radiation in an infinite medium (non-linear problem) and radiation in cavity with grey-diffuse walls (non-linear and non-local problem). The derived homogenized models are conduction problems with an effective conductivity which depend on the considered radiation. Thus we introduce a framework (homogenization and validation) based on mathematical justification using the two-scale convergence method and numerical validation by simulations using the computer code CAST3M. This study, performed for gas cooled reactors cores, can be extended to other perforated domains involving the considered heat transfer phenomena. (author)

  20. Isolement et identification des levures.

    Directory of Open Access Journals (Sweden)

    S. DOMERCQ

    1967-06-01

    Full Text Available La fermentation du moût de raisin est assurée par les levures qui se trouvent sur la pellicule du raisin, sur les rafles, et aussi, par celles qui envahissent le matériel de vendange et de vinification dès que la récolte est commencée. L'apparition deLa fermentation du moût de raisin est assurée par les levures qui se trouvent sur la pellicule du raisin, sur les rafles, et aussi, par celles qui envahissent le matériel de vendange et de vinification dès que la récolte est commencée. L'apparition des signes de la fermentation est spontanée. La fermentation est rapide dans la majorité des cas, si elle devient trop violente et que la température s'élève dangeureusement, il faut la « canaliser », la calmer. Des accidents peuvent se produire; des arrêts de fermentation laissant des sucres non fermentés pouvant être attaqués par d'autres microorganismes, des développements de levures formant des substances nuisibles à la qualité; par la suite, il s'agit d'obtenir la stabilité du vin, en particulier, éviter les refermentations des vins doux. L'étude de ces problèmes nécessite une étude préliminaire, celle des levures responsables de la fermentation alcoolique du jus de raisin, qui ne peut être faite que sur des cultures pures, isolées au préalable à l'aide de prélèvements soigneusement réalisés.s signes de la fermentation est spontanée. La fermentation est rapide dans la majorité des cas, si elle devient trop violente et que la température s'élève dangeureusement, il faut la « canaliser », la calmer. Des accidents peuvent se produire; des arrêts de fermentation laissant des sucres non fermentés pouvant être attaqués par d'autres microorganismes, des développements de levures formant des substances nuisibles à la qualité; par la suite, il s'agit d'obtenir la stabilité du vin, en particulier, éviter les refermentations des vins doux. L'étude de ces problèmes nécessite une étude pr

  1. Le Débat des semences

    International Development Research Centre (IDRC) Digital Library (Canada)

    Solutions pour les lois nationales régissant le contrôle des ressources génétiques et des ...... des pouvoirs) qui reconnaissent, dans une certaine mesure, les droits de gestion collectifs des ...... documentés, les performances physiques, etc.

  2. Mécanique des sols et des roches

    CERN Document Server

    Vullier, Laurent; Zhao, Jian

    2016-01-01

    La mécanique des sols et la mécanique des roches sont des disciplines généralement traitées séparément dans la littérature. Pour la première fois, un traité réunit ces deux spécialités, en intégrant également les connaissances en lien avec les écoulements souterrains et les transferts thermiques. A la fois théorique et pratique, cet ouvrage propose tout d'abord une description détaillée de la nature et de la composition des sols et des roches, puis s'attache à la modélisation de problèmes aux conditions limites et présente les essais permettant de caractériser les sols et les roches, tant d'un point de vue mécanique qu'hydraulique et thermique. La problématique des sols non saturés et des écoulements multiphasiques est également abordée. Une attention particulière est portée aux lois de comportement mécanique et à la détermination de leurs paramètres par des essais in situ et en laboratoire, et l'ouvrage offre également une présentation détaillée des systèmes de classi...

  3. Fast flux measurements by means of threshold detectors on the reactor 'Melusine'; Mesures de flux rapides a l'aide de detecteurs a seuil sur le reacteur 'Melusine'

    Energy Technology Data Exchange (ETDEWEB)

    Leger, P; Sautiez, B [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    Using existing data on the (n,p) and (n,{alpha}) threshold reactions we have carried out fast flux measurements on the swimming pool type reactor 'Melusine'. Four common elements: P, S, Mg, Al were chosen because from the point of view of fast spectrum analysis they represent a fairly good energy range from 2.4 MeV to 8 MeV. The fission flux value found in the central element at a power of 1 MW is 1.4 x 10{sup 13} n/cm{sup 2}/s {+-} 0.14. (author) [French] A l'aide des donnees actuelles sur les reactions a seuil (n,p) et (n,{alpha}) nous avons realise des mesures de flux rapide dans le reacteur du type piscine 'Melusine'. Quatre corps courants: P, S, Mg, Al, ont ete choisis parce qu'ils constituent au point de vue de l'analyse du spectre rapide un assez bon etalement en energie de 2,4 MeV A 8 MeV. La valeur du flux de fission trouve dans l'element central a une puissance de 1 MW est de 1,4.10{sup 13} n/cm{sup 2}/s {+-} 0,14. (auteur)

  4. Chirurgie des grassmanniennes

    CERN Document Server

    Lafforgue, Laurent

    2003-01-01

    Les compactifications diverses de variétés de modules sont un thème important et récurrent des mathématiques modernes, et elles connaissent un grand nombre d'applications. Ce livre traite le cas de cellules de Schubert minces, qui sont de sous-variétés naturelles de grassmanniennes. L'auteur a été amené à traiter ces questions par un cas particulier lié à ses travaux sur le programme de Langlands. Dans cette monographie, il en développe une théorie plus systématique, présentant le fortes similarités avec celle des modules du courbes stables. The various compactifications of moduli spaces are an important recurrent theme of modern mathematics, and they have a large number of applications. This book treats the case of thin Schubert varieties, which are natural subvarieties of Grassmannians. The author was led to these questions by a particular case linked to his work on the Langlands program. In this monograph, he develops the theory in a more systematic way, which exhibits strong similarities...

  5. Comportement des polluants des eaux pluviales urbaines en ...

    African Journals Online (AJOL)

    développement et la croissance des organismes vivant dans l'eau et particulièrement les micro- organismes. Le suivi des températures enregistrées oscille entre 9 et 16°C dans les trois sites d'observation durant la période ... de la lumière du soleil. Le site C est bien aéré et .... Effets de différents modes de gestion des eaux ...

  6. Approche historique des classifications en psychiatrie

    OpenAIRE

    Garrabé , J.

    2011-01-01

    Resume Des le milieu du xixe siecle s?est posee la question des criteres de classification des maladies. Pour les maladies mentales, diverses classifications ont alors ete proposees par des auteurs francais (Morel) et allemands (Kahlbaum, Kraepelin). A partir de la fin du xixe siecle, le Bureau International de Statistique (Paris) a publie a une Classification Internationale des Maladies, a revision decennale (J. Bertillon). Cette tache a ete poursuivie dans l?entre-deux-guerres pa...

  7. Complications du traitement traditionnel des fractures : aspects ...

    African Journals Online (AJOL)

    Tous les patients reçus avec des complications du traitement traditionnel des fractures ont été inclus dans ce travail. Le diagnostic des lésions était clinique et radiologique. Nous avions reçu 51 patients porteurs de complications suite à des traitements de médecine traditionnelle, soit 13,7% du total des patients hospitalisés ...

  8. Des cartes dans la classe…

    Directory of Open Access Journals (Sweden)

    R. Gimeno

    1990-09-01

    Full Text Available La majorité des enseignants qui veulent faire des cartes — et les faire réaliser aux élèves — pour répondre aux exigences des instructions officielles, doivent surmonter leur manque de compétences en cartographie et en didactique ainsi que les difficultés propres aux logiciels de cartographie encore peu performants. Ces compétences et la réflexion qui les accompagne sont pourtant accessibles aux enfants de l’école élémentaire…

  9. Diversification des moyens de subsistance des petits producteurs de ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Cette subvention permettra à l'Institut international de recherche sur les cultures des zones tropicales ... In ROSSA's latest bulletin issue: A farewell message from Simon Carter, the Regional Director of the ... Cigarette Taxation in Tanzania.

  10. Integrator drawer with pre-adjusted time for the study of decay of very low activity sources; Tiroir integrateur a temps preregle pour l'etude de decroissance des sources de tres faible activite

    Energy Technology Data Exchange (ETDEWEB)

    Couly, J. P.

    1962-07-01

    The author presents a drawer which can be adapted on standard counting assemblies to control the decay of very low activity sources such as samples aimed at atmospheric control. The operation principle relies on charging a tank capacitor with pulses received from a sensor. The resulting voltage is measured by a high input resistance circuit, and then recorded. The tank capacitor is periodically discharged by pulses from a time base circuit. The recording appears under the form of rays. Their length corresponds to the counting rate and the extremity envelope represents the source activity decay curve as a function of time [French] Ce tiroir, pouvant s'adapter sur les ensembles de comptage standards, permet de suivre la decroissance de sources radioactives de tres faible activite (de l'ordre de 10{sup -9} curie) tels que les prelevements de controle atmospherique. Le principe de fonctionnement consiste a charger un condensateur reservoir avec les impulsions recues du detecteur, et prealablement mises en forme. La tension resultante est mesuree par un circuit a grande resistance d'entree puis enregistree a l'aide d'un enregistreur MECI monovoie. Le condensateur reservoir est decharge periodiquement par des impulsions provenant d'un circuit de base de temps. L'enregistrement apparait sous la forme de traits, leur longueur correspond au taux de comptage et l'enveloppe de leur extremite represente la courbe de decroissance de l'activite de la source en fonction du temps. (auteur)

  11. Normal tissue tolerance to external beam radiation therapy: Adult bone; Dose de tolerance a l'irradiation des tissus sains: l'os chez l'adulte

    Energy Technology Data Exchange (ETDEWEB)

    Sargos, P.; Mamou, N.; Dejean, C.; Henriques de Figueiredo, B.; Kantor, G. [Departement de radiotherapie, Centre regional de lutte contre le cancer, institut Bergonie, 33 - Bordeaux (France); Huchet, A. [Departement de radiotherapie, hopital Saint-Andre, 33 - Bordeaux (France); Italiano, A. [Service d' oncologie medicale, Centre regional de lutte contre le cancer, institut Bergonie, 33 - Bordeaux (France)

    2010-07-15

    Radiation tolerance for bone tissue has been mostly evaluated with regard to bone fracture. Main circumstances are mandibula osteoradionecrosis, hip and costal fracture, and patent or radiologic fractures in the treated volume. After radiation therapy of bone metastasis, the analysis of related radiation fracture is difficult to individualize from a pathologic fracture. Frequency of clinical fracture is less than 5% in the large series or cohorts and is probably under-evaluated for the asymptomatic lesions. Women older than 50 years and with osteoporosis are probably the main population at risk. Dose-effect relations are difficult to qualify in older series. Recent models evaluating radiations toxicity on diaphysa suggest an important risk after 60 Gy, for high dose-fraction and for a large volume. (authors)

  12. L'exode des cerveaux et le renforcement des capacités en Afrique ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    1 févr. 2011 ... Ce phénomène ébranle les assises économiques et politiques de bien des pays africains. ... le défi consiste à recruter ces cerveaux. ... des missions africaines, des organisations non gouvernementales et des groupes de la diaspora réunis pour parler de l'exode des cerveaux en Afrique et des stratégies à ...

  13. Evaluation des pratiques de gestion des adventices en riziculture ...

    African Journals Online (AJOL)

    Le riz est l'aliment principal pour la quasi-totalité des populations vivant en Côte d'Ivoire. Cependant, les adventices sont considérées comme la contrainte biologique la plus importante faisant obstacle à la production rizicole. L'objectif de cette étude menée en 2015 était d'évaluer différentes techniques de gestion des ...

  14. Cartographie des zones d'intervention des partenaires techniques et ...

    African Journals Online (AJOL)

    cartographier les zones d'intervention des partenaires techniques et financiers au Bénin. L'approche méthodologique utilisée a consisté à la recherche documentaire, à la collecte de données auprès des partenaires techniques et financiers et à l'analyse de ces données. Les résultats ont permis de constater que cent dix ...

  15. Modernisation des marchés agroalimentaires - inclusion des petits ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Les marchés agroalimentaires connaissent de rapides changements dans les pays en développement et les pays en transition. Sous l'influence de la libéralisation du commerce et des nouvelles technologies de transformation des aliments et de commerce de détail, les marchés agroalimentaires évoluent vers une plus ...

  16. Special equipment for processing can-rupture measurements; Equipement specialise de traitement des mesures de rupture de gaines

    Energy Technology Data Exchange (ETDEWEB)

    Kaiser, J.; Phalippou, J.; Dumont, D.; Viellard, R. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    installees sur des reacteurs nucleaires utilisent dans la partie du traitement des mesures en totalite ou en partie un calculateur numerique. La fiabilite du systeme est limitee par celle du calculateur, celui-ci representant un point commun pour tout le traitement DRG. Pour satisfaire aux exigences de la securite de fonctionnement il faudrait envisager dans certains cas de doubler le calculateur. L'utilisation d'un calculateur necessite comme interface entre l'equipement de detection et lui-meme des echelles fonctionnant en integrateur pour les impulsions sortant du detecteur. En ajoutant un certain nombre de circuits a ces echelles on est capable d'effectuer le travail demande actuellement au calculateur, en ce qui concerne le calcul. Ce raisonnement nous a conduit a une solution dite ''decentralisee'' en realisant des equipements specialises au niveau du prospecteur meme. Nous croyons que cette solution represente, en dehors de l'aspect de fiabilite, surtout un interet economique. Dans notre solution, le point commun dans le traitement d'information se situe maintenant non plus au niveau d'elaboration du resultat comme dans le cas du calculateur, mais a un niveau plus bas, dans l'impression des resultats. Meme dans le cas d'une defaillance du point commun, les resultats sont elabores, affiches et compares aux seuils d'alarme. Dans le cas d'une panne d'un equipement specialise les resultats de ce prospecteur ne sont plus disponibles, les autres restent en fonction. Il semble que cette solution represente un degre de fiabilite meilleur que la solution utilisant les calculateurs universels. L'utilisation d'une technique a tiroir interchangeable (MULTIBLOC) permet un remplacement rapide de l'equipement specialise en panne. L'emploi systematique des circuits integres (TTL) assure une fiabilite accrue de l'equipement. (auteur)

  17. Die Versprachlichung des Sakralen

    DEFF Research Database (Denmark)

    Larsen, Øjvind

    2011-01-01

    transformation of the sacred as a harmonious theory of secularization. However, if we follow Weber in his religious-sociological considerations of modernity, we reach a tragic theory of secularization that poses the real problem that modernity’s connection to the sacred has been dissolved.......Habermas claims in connection with his development of the theory of communicative action that the sacred is transformed in a positive way and can take the form of free deliberation in society, the so-called Versprachlichung des Sakralen. The thesis is that the authority which could be found...... in religion and which is of fundamental significance for the integration of pre-modern societies is taken over by modern societies in forms of deliberation. Habermas develops his thesis in a discussion of Durkheim’s religious-sociological considerations. Habermas presents his thesis about the linguistic...

  18. Code des baux 2018

    CERN Document Server

    Vial-Pedroletti, Béatrice; Kendérian, Fabien; Chavance, Emmanuelle; Coutan-Lapalus, Christelle

    2017-01-01

    Le code des baux 2018 vous offre un contenu extrêmement pratique, fiable et à jour au 1er août 2017. Cette 16e édition intègre notamment : le décret du 27 juillet 2017 relatif à l’évolution de certains loyers dans le cadre d’une nouvelle location ou d’un renouvellement de bail, pris en application de l’article 18 de la loi n° 89-462 du 6 juillet 1989 ; la loi du 27 janvier 2017 relative à l’égalité et à la citoyenneté ; la loi du 9 décembre 2016 relative à la transparence, à la lutte contre la corruption et à la modernisation de la vie économique ; la loi du 18 novembre 2016 de modernisation de la justice du xxie siècle

  19. Contribution to the study of recovery mechanisms to be considered in the selection of MOS-type components used in radiative environments; Contribution a l'etude des mecanismes de guerison intervenant dans la selection des composants de type MOS utilises en environnements radiatifs

    Energy Technology Data Exchange (ETDEWEB)

    Quittard, O

    1999-12-01

    The generalized use of commercial devices in a radiative environment (nuclear power plant, spatial) raises the problem of the sensitivity of electronic equipment to the radiation induced dose effect. Irradiation of electronic devices has varying impact on their electrical characteristics, according to the concomitant bias scenario. Under bias, there is a process of continuous degradation; but recovery will occur if subsequent irradiation is performed without bias voltage. This phenomenon is known as RICN (Radiation-Induced Charge Neutralization). On the other hand, increasingly widespread use of radiation-sensitive commercial off-the-shelf components (COTS) has raised interest in exploring the degradation and recovery phenomena encountered during the irradiation as a function of bias. In this work, a general method for selecting MOS devices is presented which takes into account their operating conditions (temperature, bias). After a description of the physical phenomena responsible for the oxide-trapped charge evolution, we present the RICN annealing and their implications on devices selection in a radiative environment. The tests describes in this study were performed on SRAMs and on a set of CMOS inverts from three manufacturers. In the last section, we compare our analytical model of RICN annealing with experimental data. (authors)

  20. Digitalisierung des Kulturellen Erbes (Europas)

    NARCIS (Netherlands)

    Gruber, Marion

    2011-01-01

    Gruber, M. R. (2011, 13 December). Digitalisierung des Kulturellen Erbes (Europas). Guest lecture at the IPMZ - Institute of Mass Communication and Media Research, Devision Media Change & Innovation, University of Zurich, Switzerland.

  1. Studies on the Influence of Tritium Radiation on Anaerobic Bacteria from the Bovine Rumen; Influence de l'Irradiation par le Tritium sur les Bacteries Anaerobies du Rumen des Bovins; 0418 0441 0414 ; Estudios sobre los Efectos de las Radiaciones del Tritio en las Bacterias Anaerobias de la Panza de los Bovinos

    Energy Technology Data Exchange (ETDEWEB)

    Brueggemann, J.; Giesecke, D. [Institute of Physiology and Animal Nutrition, University of Munich, Munich, Federal Republic of Germany (Germany)

    1962-02-15

    The bacterial flora in the bovine rumen is mainly composed of strictly anaerobic species supplying the host with large amounts of volatile fatty acids (VFA's) as the main energy source. Long time in-vitro irradiations of the flora with T{sub 2}O in a so-called ''artificial rumen'' under anaerobic conditions have shown that doses up to 75 Krad had no inhibitory effect on bacterial growth and VFA-production. Stimulatory effects resulting in acceleration of cell division and increased amounts of VFA's were observed after irradiating the resting flora at 0 Degree-Sign C with a total dose of about 300 Krad within 20 d, but reproducibility was unsatisfactory because of the heterogeneity of the material. Further experiments were carried out on pure cultures of selected strains of rumen bacteria. Doses up to 150 Krad (5 d) did not markedly influence anaerobic growth and carbohydrate metabolism. However, if oxygen was present during the irradiation of resting cells a strong reduction in viable numbers was noted. Oxygen per se was found to exert a lethal effect on these species following a logarithmic order of decline. It is assumed that secondary radiation products, especially H{sub 2}O{sub 2}, are mainly responsible for the action of T{sub 2}O on these microorganisms which are devoid of catalase. Some confirmatory results are still to be obtained. (author) [French] La flore bacterienne du rumen des bovins se compose surtout d'especes strictement anaerobies qui fournissent a l'hote, comme principale source d'energie, de grandes quantites d'acides gras volatils (AGV). Des irradiations de longue duree de la flore par T{sub 2}O, faites in vitro dans un 'rumen artificiel', en anaerobie, ont montre que des doses allant jusqu'a 75 krads n'ont aucun effet inhibiteur sur la croissance des bacteries et sur la production d'AGV. Des effets stimulateurs, se traduisant par une division cellulaire acceleree et par une production accrue d'AGV, ont ete observes apres irradiation de la

  2. Vecteurs Singuliers des Theories des Champs Conformes Minimales

    Science.gov (United States)

    Benoit, Louis

    En 1984 Belavin, Polyakov et Zamolodchikov revolutionnent la theorie des champs en explicitant une nouvelle gamme de theories, les theories quantiques des champs bidimensionnelles invariantes sous les transformations conformes. L'algebre des transformations conformes de l'espace-temps presente une caracteristique remarquable: en deux dimensions elle possede un nombre infini de generateurs. Cette propriete impose de telles conditions aux fonctions de correlations qu'il est possible de les evaluer sans aucune approximation. Les champs des theories conformes appartiennent a des representations de plus haut poids de l'algebre de Virasoro, une extension centrale de l'algebre conforme du plan. Ces representations sont etiquetees par h, le poids conforme de leur vecteur de plus haut poids, et par la charge centrale c, le facteur de l'extension centrale, commune a toutes les representations d'une meme theorie. Les theories conformes minimales sont constituees d'un nombre fini de representations. Parmi celles-ci se trouvent des theories unitaires dont les representation forment la serie discrete de l'algebre de Virasoro; leur poids h a la forme h_{p,q}(m)=[ (p(m+1) -qm)^2-1] (4m(m+1)), ou p,q et m sont des entiers positifs et p+q= 2. Ces representations possedent un sous-espace invariant engendre par deux sous-representations avec h_1=h_{p,q} + pq et h_2=h_{p,q} + (m-p)(m+1-q) dont chacun des vecteurs de plus haut poids portent le nom de vecteur singulier et sont notes respectivement |Psi _{p,q}> et |Psi_{m-p,m+1-q}>. . Les theories super-conformes sont une version super-symetrique des theories conformes. Leurs champs appartiennent a des representation de plus haut poids de l'algebre de Neveu-Schwarz, une des deux extensions super -symetriques de l'algebre de Virasoro. Les theories super -conformes minimales possedent la meme structure que les theories conformes minimales. Les representations sont elements de la serie h_{p,q}= [ (p(m+2)-qm)^2-4] /(8m(m+2)) ou p,q et m sont

  3. Study of consequences of a ionizing radiation exposure on the health of persons having stay at the Marie Curie school of Nogent-sur-Marne (Val-de-Marne); Etude des consequences d'une exposition aux rayonnements ionisants sur la sante des personnes ayant sejourne a l'ecole Marie Curie de Nogent-sur-Marne (Val-de-Marne)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-03-01

    This study follows two other ones about the same subject. No one could bring elements to the question of the exposure impact on the population having stayed in the school. The old pupils and personnel have been exposed to radiation doses higher to the limit values of public exposure especially before 1987. The scientific knowledge suggest that the eventual sanitary consequences are in the area of low risks. The lack of exhaustiveness in the inquiry realisation and the lack of statistical power did not allow to measure the sanitary impact of ionizing radiation exposure among the former pupils of the Marie Curie school of Nogent sur Marne. (N.C.)

  4. Application of Radiation for the Control of Salmonellae in Various Foods; Destruction des Salmonellae par les Rayonnements dans Divers Produits Alimentaires; Primenenie izluchenij dlya unichtozheniya salmonell v razlichnykh pishchevykh produktakh; Empleo de las Radiaciones Ionizantes en la Lucha Contra las Salmonellae de Diferentes Aumentos

    Energy Technology Data Exchange (ETDEWEB)

    Ley, F. J. [Wantage Research Laboratory (A.E.R.E.), Wantage, Berks. (United Kingdom)

    1966-11-15

    Microbiological studies on the use of ionizing radiation for the elimination of Salmonellae from various foods have demonstrated that a wide variety of factors can influence the radiation sensitivity of the organisms. These factors include the nature of the food itself and the temperature during irradiation, e.g. whether frozen or unfrozen. The difference in resistance of different serotypes of Salmonellae irradiated under the same conditions has also been well established. Dose/survival curves constructed for the purpose of making a choice of dose for a particular application must therefore be established for the practical conditions envisaged and be based on the most resistant serotype present. Since these conditions can never be exactly reproduced in the laboratory, the choice of dose should be confirmed by a substantial amount of work with the naturally-contaminated material. It is apparent that the doses required for the treatment of various foods lie within the' range 0.5 to 1.0 Mrad, achieving a reduction in numbers of initial populations by a factor of between 10{sup 5} and 10{sup 7} . The most promising processes are those considered for frozen and dried-egg products, frozen meats and animal feedingstuffs. (author) [French] A la suite d'etudes microbiologiques sur la possibilite d'employer des rayonnements ionisants pour detruire les Salmonellaedans divers produits alimentaires, il est apparu que la radio- sensibiliteide ces organismes depend de nombreux facteurs, en particulier de la nature du produit et de sa temperature (produit congele ou non) pendant l'irradiation. On a egalement reconnu que diverses varietes serologiques de Salmonellae, irradiees dans les memes conditions, ont une radioresistance differente. Des,courbes de survie en fonction de la dose, construites en vue de determiner la dose necessaire poiir Un traitement' donne, doivent donc etre etablies pour les conditions pratiques envisagees et compte tenu de la plus resistante des varietes

  5. Potential biological indicators of multi-organ damage: Application to radiation accident victims; Bio-indicateurs potentiels d'atteinte multi-organe: application au cas des victimes d'irradiation accidentelles

    Energy Technology Data Exchange (ETDEWEB)

    Bertho, J.M.; Souidi, M.; Gourmelon, P. [Institut de Radioprotection et de Surete Nucleaire (IRSN), Dir. de la Radioprotection de l' Homme 92 - Fontenay-aux-Roses (France)

    2009-09-15

    Accidental irradiations induce a complex pathological situation, difficult to assess and to treat. However, recent results describing new biological indicators of radiation-induced damages such as Flt3-ligand, citrulline and oxy-sterol concentration in the plasma, together with results obtained in large animal models of high dose irradiation, allowed a better understanding of pathophysiological mechanisms induced by uncontrolled irradiations. This conducted to leave the classical paradigm of the acute radiation syndrome, described as the association of three individual syndromes, the hematopoietic syndrome, the gastro-intestinal syndrome and the cerebrovascular syndrome, in favour of a multiple organ dysfunction syndrome, with the implication of other organs and systems. Follow-up of victims from two recent radiation accidents brings a confirmation of the usefulness of the newly described biological indicators, and also a partial confirmation of this new concept of a multiple organ dysfunction syndrome. (authors)

  6. Modeling of radionuclide transport through rock formations and the resulting radiation exposure of reference persons. Calculations using Asse II parameters; Modellierung des Transports von Radionukliden durch Gesteinsschichten und der resultierenden Strahlenexposition von Referenzpersonen. Berechnungen mit Parametern der Asse II

    Energy Technology Data Exchange (ETDEWEB)

    Kueppers, Christian; Ustohalova, Veronika; Steinhoff, Mathias

    2012-05-21

    The long-term release of radioactivity into the ground water path cannot be excluded for the radioactive waste repository Asse II. The possible radiological consequences were analyzed using a radio-ecological scenario developed by GRS. A second scenario was developed considering the solubility of radionuclides in salt saturated solutions and retarding/retention effects during the radionuclide transport through the cap rock layers. The modeling of possible radiation exposure was based on the lifestyle habits of reference persons. In Germany the calculation procedure for the prediction of radionuclide release from final repositories is not defined by national standards, the used procedures are based on analogue methods from other radiation protection calculations.

  7. L'accumulation des métaux lourds au niveau des cultures : Cas des ...

    African Journals Online (AJOL)

    Le Bassin de Sebou présente une importance socio-économique pour le Maroc. En effet, il est sujet de diverses utilisations ; eau potable, eau d'irrigation et eau industrielle. Toutefois, ce bassin subit des pressions multiples, notamment par la pollution métallique. Considérant le risque de bioaccumulation des métaux par ...

  8. Radiation exposure of the radiological staff caused by radiography of small mammals, reptiles and birds; Untersuchungen zur Strahlenexposition des radiologisch taetigen Personals bei der Radiographie von Heimtieren, Reptilien sowie Zier- und Wildvoegeln

    Energy Technology Data Exchange (ETDEWEB)

    Eckert, Yvonne

    2015-05-27

    Radiography is often used as an advanced examination to ensure a diagnosis in avian, reptiles and small mammal's medicine. The aims of this thesis were: 1. To measure the radiation exposure of radiological staff caused by radiography of small mammals, reptiles and birds. The exposure of relevant body regions were measured during clinical routine. 2. To examine the differences of radiation exposures caused by radiography of different animal species and to determine the influence of dose-dependent parameters. 3. To present the radiation protection measures of the clinic and to discuss possible improvements. 4. To weigh the anaesthetic risk for small mammals, reptiles and birds against the radiation exposure of the radiological staff. The measurements took place during clinical routine of the Clinic for Exotic Pets, Reptiles, Pet and Feral Birds, University of Veterinary Medicine Hannover, Foundation. The radiation exposure of the radiological staff was measured. The radiological staff included veterinarians, veterinary-medical technical assistants, doctoral candidates and students during their practical year. Furthermore, the radiation exposure was measured at ten representative body regions using thermoluminescence dosimetry. The measuring positions included the eye-lenses, thyroid, thoracic region under the protective clothes, thoracic region above the protective clothes, gonads, fingers and the left foot. Except for one position that was measured under the protective clothes all positions measured above the protective clothes. Moreover at each examination the focus-film-distance, the kV-number, the mAs-product and the weight of the patient was recorded. Additionally the size of the examiner and the examiner's position regarding to the X-ray table were recorded as variable, dose-influencing parameters. Altogether, measurements were taken from 366 individual examiners. In all three divisions 792 X-ray images were made and 3660 dose values recorded. The

  9. Experimental measurement of neutron spectrum in the reflector of a light water reactor; Determination experimentale du spectre des neutrons dans le reflecteur d'une pile a eau legere

    Energy Technology Data Exchange (ETDEWEB)

    Brethe, P [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1963-09-15

    1. Thermal neutrons: The temperature of the thermal neutron spectrum was calculated using Au-Lu foils. This temperature varies from 300 deg. K (temperature of the moderator) at 30 cm of the core to 350 deg. K in a hole of the core. 2. Slowing down of neutron: Four resonance detectors have been used (Au, In, Co, Mn). We can write a 1/E form of the spectrum. The linking up energy E{sub M} between thermal neutron spectrum and slowing down spectrum is about 0.23 eV and is free from the Maxwell spectrum temperature. The decrease of slowing down flux regarding thermal flux, farther from the core, has been showed. 3. Fast neutrons: We used 3 threshold detectors (Ni, Al, Mg). We supposed a E{sup 1/2} e{sup -{beta}}{sup E} from of the spectrum above 3 MeV. The values of {beta} are in a range from 0.775, at the centre of the core and in a loop-hole, to 0,64 at about 30 cm of the core. 4. Continuous shape of the spectrum: The following interpolations give useful informations between the field where measurements have been made: between 340 eV and 10 keV: 1/E form between 10 keV and 330 keV: 1/(E {sigma}{sub S}(E)) form ({sigma}{sub S}(E) elastic scattering section on hydrogen) between 330 keV and 3 MeV: calculated form by the moments method (ref. BSR). (author) [French] 1. Neutrons thermiques: La temperature du spectre des neutrons thermiques a ete determinee par la methode (or-lutecium). Cette temperature varie de 300 deg. K (temperature du moderateur) a 30 cm du coeur, a 350 deg. K dans une encoche du coeur. 2. Neutrons en ralentissement: 4 detecteurs resonnants ont ete employes (Au, In, Co, Mn). Le spectre peut etre mis sous la forme 1/E quelle que soit la distance a la limite coeur-reflecteur. L'energie de raccordement E{sub M} entre spectre des neutrons thermiques et spectre en ralentissement est environ 0,23 eV et independante de la temperature du spectre de Maxwell. La diminution relative du flux en ralentissement par rapport au flux thermique quand la distance au coeur

  10. Application of recommendations and regulations in radiation protection for occupational exposures in the medical field; Application des recommandations et reglementations en radioprotection pour les expositions professionnelles dans le domaine medical

    Energy Technology Data Exchange (ETDEWEB)

    Kalifa, G; Boussard, J M [Hopital Saint-Vincent-de-Paul, 75 - Paris (France); Bonnin, A [Hopital Cochin, Serv. Radiologie75 - Paris (France); Lefaure, Ch [Centre d' Etudes sur l' Evaluation de la Protection dans le domaine Nucleaire (CEPN), 92 - Fontenay-aux-Roses (France)

    1998-07-01

    The improvement of the workers radiation protection in the medical field goes through a better sensitization of the different categories of implied personnel. Choices must be made in reconciling the different principles: precaution, the health costs control and the fundamental principle of quality of the diagnosis and the medical attention brought to the patients.

  11. Studies of the source complex behaviour and of the ultrasound radiation of contact flexible multi-element transducers; Etudes du comportement complexe de source et du rayonnement ultrasonore des traducteurs multi-elements flexibles au contact

    Energy Technology Data Exchange (ETDEWEB)

    Amory, V

    2007-12-15

    This work deals with the ultrasonic nondestructive testing of parts with complex geometries using soft multi-element sensors. The different types of contact control configurations are presented first. Then, the difficulties encountered with conventional contact transducers are explained and the multi-element piezoelectric transducers technology, developed to meet these difficulties, is presented. The second chapter presents the results of finite-element calculations showing the complexity of a transducer in a condition of testing utilization. In a same configuration, the radiated far field calculated by finite-elements is compared to the measurement in order to validate the way the source behaviour is calculated. However, despite the efficiency of the finite-elements simulation, this tool is numerically too costly and cannot be used to optimize a full multi-element transducer. Therefore, a realistic source model is built and implemented in a radiation code based on high-frequency asymptotic approximations where only L and T volume waves are calculated. The incapacity of this model to reproduce the behaviour of T waves in some directions of propagation has led to give a particular attention to the fore-waves, neglected in the radiation calculation. Chapter 3 treats of the building of an exact radiation model taking into consideration the fore-waves contribution emitted by a contact transducer exerting a random space-time distribution constraint at the surface of the considered medium. A radiation model, based on the calculation of exact Green functions of the Lamb problem is proposed. The exact model is particularly interesting in the case of sensor geometries with a long length with respect to other dimensions (2D case). Field calculation results are shown for an element of the matrix network (3D case) and for a linear element (2D case). A study of different existing approached models is carried out as well. The last chapter presents some results of the field

  12. Exposition of the operator's eye lens and efficacy of radiation shielding in fluoroscopically guided interventions; Exposition der Augenlinse des Untersuchers und Effizienz der Strahlenschutzmittel bei fluoroskopischen Interventionen

    Energy Technology Data Exchange (ETDEWEB)

    Galster, M.; Adamus, R. [Klinikum Nuernberg-Nord, Nuernberg (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie; Guhl, C. [Klinikum Nuernberg (Germany). Inst. fuer Medizinische Physik; Uder, M. [Erlangen Univ. (Germany). Radiologisches Inst.

    2013-05-15

    Purpose: Efficacy of radiation protection tools for the eye lens dose of the radiologist in fluoroscopic interventions. Materials and Methods: A patient phantom was exposed using a fluoroscopic system. Dose measurements were made at the eye location of the radiologist using an ionization chamber. The setting followed typical fluoroscopic interventions. The reduction of scattered radiation by the equipment-mounted shielding (undercouch drapes and overcouch top) was evaluated. The ceiling-suspended lead acrylic glass screen was tested in scattered radiation generated by a slab phantom. The protective properties of different lead glass goggles and lead acrylic visors were evaluated by thermoluminescence measurements on a head phantom in the primary beam. Results: The exposition of the lens of about 110 to 550 {mu}Sv during radiologic interventions is only slightly reduced by the undercouch drapes. Applying the top in addition to the drapes reduces the lens dose by a factor of 2 for PA projections. In 25 LAO the dose is reduced by a factor between 1.2 and 5. The highest doses were measured for AP angulations furthermore the efficacy of the equipment-mounted shielding is minimal. The ceiling-suspended lead screen reduced scatter by a factor of about 30. The lead glass goggles and visors reduced the lens dose up to a factor of 8 to 10. Depending on the specific design, the tested models are less effective especially for radiation from lateral with cranial angulation of the beam. Occasionally the visors even caused an increase of dose. Conclusion: The exposition of the eye lens can be kept below the new occupational limit recommended by the ICRP if the radiation shielding equipment is used consistently. (orig.)

  13. Study of charge correlation for Z {<=} 2 obtained in Au+Au collisions with incident energy from 150 up to 400 MeV/A. FOPI detector is used; Etude des correlations des charges Z {<=} 2 obtenues lors des collisions Au+Au aux energies incidentes de 150 a 400 MeV/A avec le detecteur fopi

    Energy Technology Data Exchange (ETDEWEB)

    Pras, Ph

    1997-01-24

    In the first part of this work we present what information can be driven from heavy ion collision studies and what can be expected from the state equation of nuclear matter. We introduce the notion of centrality and the concept of spectator-participant. The different models of collisions are reviewed. The theory of correlations between light particles is used as a tool to predict some results about the shape and population density of theoretical spectra.The Coulomb model which implies a thermal interpretation of heavy ion collisions is modified in order to take excited states into account and to reproduce the collective phenomena of flow and squeeze-out. Within the frame of this modified Coulomb model 3 notions of nuclear temperature are compared. A discussion is lead to find out the temperature of nuclear matter at the very moment of fragmentation. (A.C.) 134 refs.

  14. Technical and Economic Considerations in the Preservation of Meats and Poultry by Ionizing Radiation; Considerations d'Ordre Technique et Economique sur la Conservation des Viandes et de la Volaille par les Rayonnements Ionisants; Tekhnicheskie i ehkonomicheskie soobrazheniya otnositel'no'konservatsii myasa i ptitsy s pomoshch'yu ioniziruyushchikh izluchenij; Consideraciones Tecnicas y Economicas Acerca de la Conservacion de Carnes y Volateria por Irradiacion

    Energy Technology Data Exchange (ETDEWEB)

    Urbain, W. M. [Department of Food Science, Michigan State University, East Lansing, MI (United States)

    1966-11-15

    Radiation-sterilized meats and poultry can be of a quality better than that obtained with thermal processing. Where the normal method of preservation of meat and poultry during distribution is refrigeration, radiation at sterilizing levels is not likely to replace it. A principal reason for this is cost. In such a civilian market, radiation-sterilized meats will serve primarily as convenience foods. Radiation-pasteurization could provide a significant product life extension for fresh meats and poultry by delaying microbial spoilage, especially in the centralized preparation of retail cuts. Other factors of meat spoilage of a chemical or physical nature, however, are not controlled by radiation; and until they are, there is no real marketing value in the use of radiation. For fresh or frozen poultry there is the possibility of Salmonella control, should this be needed. Costs for sterilization and pasteurization are estimated and are presented in a form to permit selection of specific conditions within a range for certain important variables. From a commercial viewpoint, it is important to determine the consumer acceptance of radiation- sterilized meats and poultry. The usual approach to such a determination is to market the products in question in a limited manner and to measure the acceptance under such market conditions. To accomplish this with radiation-sterilized foods, the next step appears to be to obtain a production capability to supply the products for test marketing. (author) [French] Les viandes et la volaille sterilisees par les rayonnements peuvent etre de meilleure qualite que celle obtenue par un traitement thermique; Lorsqu'on utilise la refrigeration comme methode normale de conservation de la viande et de la volaille en cours de distribution, il est peu probable qu'on lui substitue l'irradiation a des doses sterilisantes. La principale raison eri est le cout eleve de l'irradiation. Dans un marche destine a repondre aux besoins civils, les viandes

  15. Measurement of {beta} Emitters by the Radiated Charge; Mesure des Emetteurs {beta} par la Charge Rayonnee. Mesure de l'activite des emetteurs {beta} a partir de la charge rayonnee; Izmerenie aktivnosti izluchatelya {beta}-chaetits na osnove izluchaemogo zaryada; Medicion de la actividad de los emisores {beta} a partir de la carga irradiada

    Energy Technology Data Exchange (ETDEWEB)

    Engelmann, J J [Centre d' Etudes Nucleaires de Saclay (France)

    1960-06-15

    The method is based on the principle recently described by Failla and his associates: Two plane electrodes of the same material are mounted parallel to, and close beside, each other in a vacuum container and the source which is to be measured is laid on one of them. The back-scattering on this electrode is offset by the reflections on the other electrode. A magnetic or electrical field makes it possible to eliminate the effect of low-energy secondary electrons. In the case of magnetic deflection, the apparatus includes an extrapolation chamber and, in the case of electrical deflection, a chamber with a very fine grille. In the case of Sr{sup 90}-Y{sup 90} and P{sup 32} the results obtained tally very well with the measurements made with the 4 {pi} counter (better than {+-} 2%) In the case of S{sup 35} the results are seen to be affected by the atomic number of the substance of which the electrode whereon the source is placed consists; this must therefore be chosen with care. The theories on back-scattering provide an explanation of these results. (author) [French] Le principe de la methode est celui decrit recemment par Failla et ses collaborateurs: Deux electrodes planes paralleles, de meme substance et tres voisines, sont disposees dans une enceinte videe. Sur une des electrodes est deposee la source a mesurer. La retrodiffusion sur l'electrode porte-source est compensee par les reflexions sur l'autre electrode. Un champ magnetique ou electrique permet d'eliminer l'effet des electrons secondaires de faible energie. Le dispositif experimental comporte, dans le cas de la deflexion magnetique, une chambre a extrapolation et dans le cas de la deflexion electrique, une chambre a grille tres fine. L'accord avec des mesures effectuees au compteur 4 {pi} est excellent dans le cas du Sr{sup 90}-Y{sup 90} et du P{sup 32} (mieux que {+-}2%). Dans le cas du S{sup 35}, les experiences mettent en evidence l'influence du nombre atomique du support de source et en imposent le

  16. Terre des hommes

    CERN Multimedia

    Staff Association

    2012-01-01

    Transformez votre téléphone portable en geste de solidarité ! Collecte du 12 au 23 novembre 2012   Faites un geste simple et utile en déposant vos téléphones portables inutilisés dans les urnes installées dans les trois restaurants du CERN. En Suisse, une personne change tous les 12 à 18 mois de téléphone portable. La plupart de nos vieux appareils sont simplement laissés à l’abandon avec comme seule fonction de parer une éventuelle panne à venir. On  estime ainsi que 8 millions de portables sont inutilisés, alors qu'entre 30 et 50% peuvent être réutilisés. L'action Solidarcomm leur offre une deuxième vie ! Terre des Hommes Suisse, dans le cadre de la campagne Solidarcomm, collecte et valorise vos téléphones inutilis&...

  17. Onlinespieler abseits des Mainstreams

    Directory of Open Access Journals (Sweden)

    Harald Baumgartlinger

    2012-12-01

    Full Text Available MMO(RPGs „Massively Multiplayer Online (Role-Playing Games“ nehmen einen Sonderstatus unter den Onlinespielen ein, welcher durch den wachsenden wirtschaftlichen Erfolg, insbesondere durch den „breakthrough hit“ (Duchenaut et al. 2006: 407 World of Warcraft (WoW, auch an Bedeutung für die Medien- und Kommunikationswissenschaft gewinnt (vgl. Inderst 2009: 15; vgl. Seifert/Jöckel 2008: 297. Der Primus des Genres, WoW, repräsentiert gemeinsam mit einigen nahezu identen Titeln insgesamt 85 Prozent der gespielten MMOGs (vgl. Williams et al. 2008: 999. Daher befasst sich auch die Mehrheit der vorliegenden Studien mit eben diesen Spielen. Neue Formen von MMO(Gs können jedoch zu ebenso neuartigen Spielerfahrungen führen und damit unterschiedliche Nutzungsmotive befriedigen (vgl. Seifert/Jöckel 2008: 309 und folglich zu einem gänzlich anderen Spielerleben führen. Während im Mainstream die kooperativen Spielerbeziehungen überwiegen, dominiert in Darkfall Online der soziale Wettbewerb. Der von Williams et al. 2008 verwendete Fragebogen diente als Rohling für die Kreation eines für die speziellen Anforderungen adaptierten Erhebungstools zur Erforschung der Spielertypologie und der Motive der Darkfall-Online-SpielerInnen. Die in der Onlinebefragung (N = 506 gesammelten Daten belegen, dass sich sowohl die Spielerdemographie, als auch die Motive der Spieler von den Mainstream MMOs unterscheiden. Zudem konnten realweltliche Eigenschaften der Spieler als signifikante Einflussfaktoren für die Spielzuwendung identifiziert werden.

  18. Proceedings of the International Conference on Modern Radiotherapy. Advances and Challenges in Radiation Protection of Patients; Actes de la conference internationale sur la radiotherapie moderne. Defis et progres dans le domaine de la radioprotection des patients

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-12-15

    The use of ionizing radiation in medicine has led to major improvements in the diagnosis and treatment of human diseases. While bringing new benefits for cancer treatment, modern radiotherapy also poses new challenges in terms of radiation protection of patients. Prevention of radiotherapy incidents and accidents is a major issue in this area. In December 2009, the French Nuclear Safety Authority (ASN) organised the 1. international conference on radiation protection of patients in radiotherapy. The major objective of the conference was to provide a platform for exchanging experience, and reviewing the actions implemented to improve the radiation safety in radiotherapy both at national and international level. The expected result was: - to reach a consensus about the necessity to strengthen existing international actions for prevention of incidents and accidents, - to set up an international cooperation to improve management for overexposed patients, - to outline a strategy for strengthening regulation, - to contribute to the elaboration of an international scale to rate patient related events for communication and reporting purpose. 360 delegates from 50 countries across the world participated at the 3-day conference. 41 presentations were made and 67 posters were displayed. The conference brought together a broad spectrum of expertise: scientists, health professionals, medical devices manufacturers, risk management specialists, radiation protection experts, representatives from Radiation Protection and Health Authorities as well as patient's associations. The programme covered both scientific and medical issues, such as patient sensitivity to ionising radiation and the treatment of complications. It also provided scope to discuss the benefits and risks of modern radiotherapy and to explore treatment safety issues from various perspectives, including human resources, expertise, education and training along with control and prevention strategies. The

  19. Gyrodactylidae et Gyrodactylose des Salmonidae

    Directory of Open Access Journals (Sweden)

    MALMBERG G.

    1993-01-01

    Full Text Available Vingt et une espèces de Gyrodactylus de Salmonidae arrangées en six groupes sont présentées. Les observations concernant ces espèces dans les milieux naturels et en pisciculture sont résumées. Sur la base de données générales relatives aux espèces de Gyrodactylus en milieu naturel en Scandinavie et Baltique, les observations biologiques, écologiques et comportementales de G. salaris Malmberg, 1957 et G. derjavini MALMBERG et MALMBERG (1987 des salmonidae sauvages des rivières norvégiennes et suédoises sont présentées. La viviparité unique, la reproduction asexuée et sexuée et le pouvoir de reproduction chez les Gyrodactylus sont développés. La Gyrodactylose à G. salaris est abordée en milieu naturel, dans les rivières norvégiennes et en pisciculture, en Suède et au Danemark. L'étude ultrastructurale des blessures causées par G. salaris ainsi que les résultats expérimentaux sur les espèces norvégiennes et canadiennes sont présentés. La distribution géographique naturelle des Salmonidae, les modifications liées à l'homme et à l'activité économique ainsi que les Salmonidae élevés sont revus. La présence de six groupes d'espèces de Gyrodactylus en Amérique du Nord et Eurasie est discutée en fonction de la distribution géographique des espèces hôtes. Il est souligné qu'une propagation intercontinentale des espèces de Gyrodactylus de Salmonidae a dû être impossible à cause de leur origine limnique d'une part et de la salinité élevée des océans atlantique et pacifique d'autre part. Les exigences micro et macro environnementales des espèces sont discutées dans les conditions naturelles et les variations saisonnières, préférendums et tolérances du parasitisme sont signalés. L'effet des conditions de pisciculture sur les espèces de Gyrocactylus sont discutées : la capacité reproductrice et de propagation ainsi que la spécificité — stricte dans la nature — peuvent être influenc

  20. Current algebra; Algebre des courants

    Energy Technology Data Exchange (ETDEWEB)

    Jacob, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    The first three chapters of these lecture notes are devoted to generalities concerning current algebra. The weak currents are defined, and their main properties given (V-A hypothesis, conserved vector current, selection rules, partially conserved axial current,...). The SU (3) x SU (3) algebra of Gell-Mann is introduced, and the general properties of the non-leptonic weak Hamiltonian are discussed. Chapters 4 to 9 are devoted to some important applications of the algebra. First one proves the Adler- Weisberger formula, in two different ways, by either the infinite momentum frame, or the near-by singularities method. In the others chapters, the latter method is the only one used. The following topics are successively dealt with: semi leptonic decays of K mesons and hyperons, Kroll- Ruderman theorem, non leptonic decays of K mesons and hyperons ( {delta}I = 1/2 rule), low energy theorems concerning processes with emission (or absorption) of a pion or a photon, super-convergence sum rules, and finally, neutrino reactions. (author) [French] La premiere partie de ce cours (trois premiers chapitres), traite des generalites concernant l'algebre de courants. Apres une definition rapide des courants faibles et un rappel de leurs proprietes (hypothese V-A, conservation du courant vecteur, regles de selection, courant axial partiellement conserve,...), l'on introduit l'algebre de Gell-Mann SU (3) x SU (3), et discute les proprietes generales de l'Hamiltonien faible non leptonique. Les chapitres IV a IX sont consacres a des applications importantes de l'algebre des courants. En premier lieu l'on demontre la formule de Adler et Weisberger, par deux methodes differentes, celle dite du repere de moment infini et celle des singularites proches. Cette derniere est seule utilisee dans la suite. Puis, l'on traite successivement les problemes suivants: desintegrations semi-leptoniques des mesons K et des hyperons, theoreme de Kroll-Ruderman, desintegrations non leptoniques des mesons

  1. Perspectives for the Use of Ionizing Radiation in the Decontamination (Salmonella Radicidation) of Some Frozen Proteinaceous Foods and Dry Mixed Feed Ingredients; Perspectives de l'Emploi des Rayonnements pour la Decontamination (Radicidation de Salmonella) de Certains Aliments Proteiques Congeles et des Constituants de Melanges Alimentaires Secs pour Animaux; Perspektivy ispol'zovaniya ioniziruyushchego izlucheniya dlya unichtozheniya bakterij (Gruppy Salmonella) nekotorykh zamorozhennykh belkovykh osnovnykh pishchevykh produktov i sukhikh komponentov smeshannogo'fura; Radiodescontaminacion (Radicidacion de la Salmonella) de Algunos Alimentos Proteicos Basicos Congelados y de Componentes de Alimentos Secos para Animales

    Energy Technology Data Exchange (ETDEWEB)

    Mossel, D. A.A. [Central Institute for Nutrition and Food Research T.N.O., Zeist (Netherlands)

    1966-11-15

    Radiation decontamination, particularly of proteinaceous staple foods of low water activity, seemed to be promising, as one of the first applications of ionizing energy in food ancieed processing because of (a) restricted radiochemical damage to the commodities concerned; (b) absence of microbial proliferation subsequent to irradiation; and (c) some, often unique, technological advantages, such as applicability to materials already packaged, e.g. mixed feed ingredients, and effective decontamination without simultaneously- losing freshness, as in the case of red meats and poultry. As a first step, laboratory-scale dose range-finding experiments in this area were carried out earlier with, at the same time, sub-acute testing for wholesomeness. The results of these experiments were very promising. Pilot-plant-scale tests were next carried out, while concurrently research on wholesomeness was extended to a full two years/three generations assay with rats. In these tests it was confirmed that a dose of the order of 0.7 {+-} 0.1 Mrad suffices for the elimination of Salmonellae from frozen and dried proteinaceous products, such as chickens, fish meal and mixed feed. If, for reasons of analytical facility, a negative Enterobacteriaceae test for representative numbers of samples of the order of 10 g of radicidized material were preferred, the radiation dose would have to be slightly raised; the strict maximum would then amount to 1.0 Mrad, e.g. when mixed feeds, initially containing higher numbers of relatively radiation-resistant, pigmented Enterobacter strains were to be treated. No consistent, radiation-dependent, untoward effects on the experimental animals used, i.e. rats and, to a lesser extent, piglets, was detected at any of the irradiation levels tested. It is, therefore, concluded that the third evaluation step can now be undertaken, that is: tentative commercial-scale decontamination experiments in the region of production. Latin American countries like Argentina

  2. ETUDE DE LA DISTRIBUTION DES CATIONS ECHANGEABLES