Sample records for radiation therapy dosimetric

  1. Radiochromic film in the dosimetric verification of intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Zhou Yingjuan; Huang Shaomin; Deng Xiaowu

    2007-01-01

    Objective: Objective To investigate the dose-response behavior of a new type of radio- chromic film( GAFCHROMIC EBT) and explore the clinical application means and precision of dosage measurement, which can be applied for: (1) plan-specific dosimetric verification for intensity modulated radiation therapy, (2) to simplify the process of quality assurance using traditional radiographic film dosimetric system and (3) to establish a more reliable, more efficient dosimetric verification system for intensity modulated radiation therapy. Methods: (1) The step wedge calibration technique was used to calibrate EBT radiochromic film and EDR2 radiographic film. The dose characteristics, the measurement consistency and the quality assurance process between the two methods were compared. (2) The in-phantom dose-measurement based verification technique has been adopted. Respectively, EBT film and EDR2 film were used to measure the same dose plane of IMRT treatment plans. The results of the dose map, dose profiles and iso- dose curves were compared with those calculated by CORVUS treatment planning system to evaluate the function of EBT film for dosimetric verification for intensity modulated radiation therapy. Results: (1) Over the external beam dosimetric range of 0-500 cGy, EBT/VXR-16 and EDR2/VXR-16 film dosimetric system had the same measurement consistency with the measurement variability less then 0.70%. The mean measurement variability of these two systems was 0.37% and 0.68%, respectively. The former proved to be the superior modality at measurement consistency, reliability, and efficiency over dynamic clinical dose range , furthermore, its quality assurance showed less process than the latter. (2) The dosimetric verification of IMRT plane measured with EBT film was quite similar to that with EDR2 film which was processed under strict quality control. In a plane of the phantom, the maximal dose deviation off axis between EBT film measurement and the TPS calculation was

  2. The pitfalls of dosimetric commissioning for intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Tohyama, Naoki; Kodama, Takashi; Hatano, K.

    2013-01-01

    Intensity modulated radiation therapy (IMRT) allows higher radiation dose to be focused to the target volumes while minimizing the dose to OAR. To start of clinical treatment in IMRTvwe must perform commissioning strictly than 3D-conformal radiotherapy (CRT). In this report, pitfalls of dosimetric commissioning for intensity modulated radiation therapy were reviewed. Multileaf collimator (MLC) offsets and MLC transmissions are important parameters in commissioning of RTPS for IMRT. Correction of depth scaling and fluence scaling is necessary for dose measurement using solid phantom. (author)

  3. Dosimetric verification of the intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Zou Huawei; Jia Mingxuan; Wu Rong; Xiao Fuda; Dong Xiaoqi

    2004-01-01

    Objective: To discuss the methods of the dosimetric verification in the intensity-modulated radiation therapy (IMRT) and insure correct execution of the IMRT planning in the clinical practice. Methods: The CMSFOCUS9200 inverse planning system was used to provide optimized 5-field IMRT treatment plans for the patients. A phantom was made from true water-equivalent material. The doses of the interesting points and isodose distributions of the interesting planes in the phantom were calculated using patients' treatment plan. The phantom was placed on the couch of the accelerator and was irradiated using the phantom's treatment planning data. The doses of interesting points were measured using a 0.23 cc chamber and the isodose distributions of interesting planes were measured using RIT 113 film dosimetry system in the phantom. The results were compared with those from calculation in planning system for verification. Results: The doses and isodose distributions measured by the chamber and the film were consistent with those predicted by the planning. The error between the measured dose and calculated dose in the interesting points was less than 3%. Conclusion: The dosimetric verification of IMRT is a reliable measure in the course of its implementation. (authors)

  4. A comparison of the quality assurance of four dosimetric tools for intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Son, Jaeman; Baek, Taesung; Lee, Boram; Shin, Dongho; Park, Sung Yong; Park, Jeonghoon; Lim, Young Kyung; Lee, Se Byeong; Kim, Jooyoung; Yoon, Myonggeun

    2015-01-01

    This study was designed to compare the quality assurance (QA) results of four dosimetric tools used for intensity modulated radiation therapy (IMRT) and to suggest universal criteria for the passing rate in QA, irrespective of the dosimetric tool used. Thirty fields of IMRT plans from five patients were selected, followed by irradiation onto radiochromic film, a diode array (Mapcheck), an ion chamber array (MatriXX) and an electronic portal imaging device (EPID) for patient-specific QA. The measured doses from the four dosimetric tools were compared with the dose calculated by the treatment planning system. The passing rates of the four dosimetric tools were calculated using the gamma index method, using as criteria a dose difference of 3% and a distance-to-agreement of 3 mm. The QA results based on Mapcheck, MatriXX and EPID showed good agreement, with average passing rates of 99.61%, 99.04% and 99.29%, respectively. However, the average passing rate based on film measurement was significantly lower, 95.88%. The average uncertainty (1 standard deviation) of passing rates for 6 intensity modulated fields was around 0.31 for film measurement, larger than those of the other three dosimetric tools. QA results and consistencies depend on the choice of dosimetric tool. Universal passing rates should depend on the normalization or inter-comparisons of dosimetric tools if more than one dosimetric tool is used for patient specific QA

  5. A comparison of the quality assurance of four dosimetric tools for intensity modulated radiation therapy.

    Science.gov (United States)

    Son, Jaeman; Baek, Taesung; Lee, Boram; Shin, Dongho; Park, Sung Yong; Park, Jeonghoon; Lim, Young Kyung; Lee, Se Byeong; Kim, Jooyoung; Yoon, Myonggeun

    2015-09-01

    This study was designed to compare the quality assurance (QA) results of four dosimetric tools used for intensity modulated radiation therapy (IMRT) and to suggest universal criteria for the passing rate in QA, irrespective of the dosimetric tool used. Thirty fields of IMRT plans from five patients were selected, followed by irradiation onto radiochromic film, a diode array (Mapcheck), an ion chamber array (MatriXX) and an electronic portal imaging device (EPID) for patient-specific QA. The measured doses from the four dosimetric tools were compared with the dose calculated by the treatment planning system. The passing rates of the four dosimetric tools were calculated using the gamma index method, using as criteria a dose difference of 3% and a distance-to-agreement of 3 mm. The QA results based on Mapcheck, MatriXX and EPID showed good agreement, with average passing rates of 99.61%, 99.04% and 99.29%, respectively. However, the average passing rate based on film measurement was significantly lower, 95.88%. The average uncertainty (1 standard deviation) of passing rates for 6 intensity modulated fields was around 0.31 for film measurement, larger than those of the other three dosimetric tools. QA results and consistencies depend on the choice of dosimetric tool. Universal passing rates should depend on the normalization or inter-comparisons of dosimetric tools if more than one dosimetric tool is used for patient specific QA.

  6. Dosimetric and Late Radiation Toxicity Comparison Between Iodine-125 Brachytherapy and Stereotactic Radiation Therapy for Juxtapapillary Choroidal Melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Krema, Hatem, E-mail: htmkrm19@yahoo.com [Department of Ocular Oncology, Princess Margaret Hospital/University Health Network, University of Toronto, Toronto, Ontario (Canada); Heydarian, Mostafa [Department of Radiation Medicine, Princess Margaret Hospital/University Health Network, University of Toronto, Toronto, Ontario (Canada); Beiki-Ardakani, Akbar [Department of Radiation Oncology, Princess Margaret Hospital/University Health Network, University of Toronto, Toronto, Ontario (Canada); Weisbrod, Daniel [Department of Ocular Oncology, Princess Margaret Hospital/University Health Network, University of Toronto, Toronto, Ontario (Canada); Xu, Wei [Department of Biostatistics, Princess Margaret Hospital/University Health Network, University of Toronto, Toronto, Ontario (Canada); Laperriere, Normand J.; Sahgal, Arjun [Department of Radiation Oncology, Princess Margaret Hospital/University Health Network, University of Toronto, Toronto, Ontario (Canada)

    2013-07-01

    Purpose: To compare the dose distributions and late radiation toxicities for {sup 125}I brachytherapy (IBT) and stereotactic radiation therapy (SRT) in the treatment of juxtapapillary choroidal melanoma. Methods: Ninety-four consecutive patients with juxtapapillary melanoma were reviewed: 30 have been treated with IBT and 64 with SRT. Iodine-125 brachytherapy cases were modeled with plaque simulator software for dosimetric analysis. The SRT dosimetric data were obtained from the Radionics XKnife RT3 software. Mean doses at predetermined intraocular points were calculated. Kaplan-Meier estimates determined the actuarial rates of late toxicities, and the log–rank test compared the estimates. Results: The median follow-up was 46 months in both cohorts. The 2 cohorts were balanced with respect to pretreatment clinical and tumor characteristics. Comparisons of radiation toxicity rates between the IBT and SRT cohorts yielded actuarial rates at 50 months for cataracts of 62% and 75% (P=.1), for neovascular glaucoma 8% and 47% (P=.002), for radiation retinopathy 59% and 89% (P=.0001), and for radiation papillopathy 39% and 74% (P=.003), respectively. Dosimetric comparisons between the IBT and SRT cohorts yielded mean doses of 12.8 and 14.1 Gy (P=.56) for the lens center, 17.6 and 19.7 Gy (P=.44) for the lens posterior pole, 13.9 and 10.8 Gy (P=.30) for the ciliary body, 61.9 and 69.7 Gy (P=.03) for optic disc center, and 48.9 and 60.1 Gy (P<.0001) for retina at 5-mm distance from tumor margin, respectively. Conclusions: Late radiation-induced toxicities were greater with SRT, which is secondary to the high-dose exposure inherent to the technique as compared with IBT. When technically feasible, IBT is preferred to treat juxtapapillary choroidal melanoma.

  7. A Dosimetric Comparison of Tomotherapy and Volumetric Modulated Arc Therapy in the Treatment of High-Risk Prostate Cancer With Pelvic Nodal Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Pasquier, David, E-mail: d-pasquier@o-lambret.fr [Departement Universitaire de Radiotherapie, Centre O. Lambret, Lille (France); Universite Lille Nord de France, Lille (France); Centre Galilee, Clinique de la Louviere, Lille (France); Cavillon, Fabrice [Universite Lille Nord de France, Lille (France); Faculte Libre de Medecine, Lille (France); Lacornerie, Thomas [Departement Universitaire de Radiotherapie, Centre O. Lambret, Lille (France); Universite Lille Nord de France, Lille (France); Touzeau, Claire [Centre Galilee, Clinique de la Louviere, Lille (France); Tresch, Emmanuelle [Unite de Methodologie et Biostatistique, Centre O. Lambret, Lille (France); Lartigau, Eric [Departement Universitaire de Radiotherapie, Centre O. Lambret, Lille (France); Universite Lille Nord de France, Lille (France)

    2013-02-01

    Purpose: To compare the dosimetric results of volumetric modulated arc therapy (VMAT) and helical tomotherapy (HT) in the treatment of high-risk prostate cancer with pelvic nodal radiation therapy. Methods and Materials: Plans were generated for 10 consecutive patients treated for high-risk prostate cancer with prophylactic whole pelvic radiation therapy (WPRT) using VMAT and HT. After WPRT, a sequential boost was delivered to the prostate. Plan quality was assessed according to the criteria of the International Commission on Radiation Units and Measurements 83 report: the near-minimal (D98%), near-maximal (D2%), and median (D50%) doses; the homogeneity index (HI); and the Dice similarity coefficient (DSC). Beam-on time, integral dose, and several organs at risk (OAR) dosimetric indexes were also compared. Results: For WPRT, HT was able to provide a higher D98% than VMAT (44.3 {+-} 0.3 Gy and 43.9 {+-} 0.5 Gy, respectively; P=.032) and a lower D2% than VMAT (47.3 {+-} 0.3 Gy and 49.1 {+-} 0.7 Gy, respectively; P=.005), leading to a better HI. The DSC was better for WPRT with HT (0.89 {+-} 0.009) than with VMAT (0.80 {+-} 0.02; P=.002). The dosimetric indexes for the prostate boost did not differ significantly. VMAT provided better rectum wall sparing at higher doses (V70, V75, D2%). Conversely, HT provided better bladder wall sparing (V50, V60, V70), except at lower doses (V20). The beam-on times for WPRT and prostate boost were shorter with VMAT than with HT (3.1 {+-} 0.1 vs 7.4 {+-} 0.6 min, respectively; P=.002, and 1.5 {+-} 0.05 vs 3.7 {+-} 0.3 min, respectively; P=.002). The integral dose was slightly lower for VMAT. Conclusion: VMAT and HT provided very similar and highly conformal plans that complied well with OAR dose-volume constraints. Although some dosimetric differences were statistically significant, they remained small. HT provided a more homogeneous dose distribution, whereas VMAT enabled a shorter delivery time.

  8. Dosimetric effects of rotational offsets in stereotactic body radiation therapy (SBRT) for lung cancer

    International Nuclear Information System (INIS)

    Yang, Yun; Catalano, Suzanne; Kelsey, Chris R.; Yoo, David S.; Yin, Fang-Fang; Cai, Jing

    2014-01-01

    To quantitatively evaluate dosimetric effects of rotational offsets in stereotactic body radiation therapy (SBRT) for lung cancer. Overall, 11 lung SBRT patients (8 female and 3 male; mean age: 75.0 years) with medially located tumors were included. Treatment plans with simulated rotational offsets of 1°, 3°, and 5° in roll, yaw, and pitch were generated and compared with the original plans. Both clockwise and counterclockwise rotations were investigated. The following dosimetric metrics were quantitatively evaluated: planning target volume coverage (PTV V 100% ), max PTV dose (PTV D max ), percentage prescription dose to 0.35 cc of cord (cord D 0.35 cc ), percentage prescription dose to 0.35 cc and 5 cc of esophagus (esophagus D 0.35 cc and D 5 cc ), and volume of the lungs receiving at least 20 Gy (lung V 20 ). Statistical significance was tested using Wilcoxon signed rank test at the significance level of 0.05. Overall, small differences were found in all dosimetric matrices at all rotational offsets: 95.6% of differences were 100% , PTV D max , cord D 0.35 cc , esophagus D 0.35 cc , esophagus D 5 cc , and lung V 20 was − 8.36%, − 6.06%, 11.96%, 8.66%, 6.02%, and − 0.69%, respectively. No significant correlation was found between any dosimetric change and tumor-to-cord/esophagus distances (R 2 range: 0 to 0.44). Larger dosimetric changes and intersubject variations were observed at larger rotational offsets. Small dosimetric differences were found owing to rotational offsets up to 5° in lung SBRT for medially located tumors. Larger intersubject variations were observed at larger rotational offsets

  9. Dosimetric effects of rotational offsets in stereotactic body radiation therapy (SBRT) for lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yun; Catalano, Suzanne; Kelsey, Chris R.; Yoo, David S.; Yin, Fang-Fang; Cai, Jing, E-mail: jing.cai@duke.edu

    2014-04-01

    To quantitatively evaluate dosimetric effects of rotational offsets in stereotactic body radiation therapy (SBRT) for lung cancer. Overall, 11 lung SBRT patients (8 female and 3 male; mean age: 75.0 years) with medially located tumors were included. Treatment plans with simulated rotational offsets of 1°, 3°, and 5° in roll, yaw, and pitch were generated and compared with the original plans. Both clockwise and counterclockwise rotations were investigated. The following dosimetric metrics were quantitatively evaluated: planning target volume coverage (PTV V{sub 100%}), max PTV dose (PTV D{sub max}), percentage prescription dose to 0.35 cc of cord (cord D{sub 0.35} {sub cc}), percentage prescription dose to 0.35 cc and 5 cc of esophagus (esophagus D{sub 0.35} {sub cc} and D{sub 5} {sub cc}), and volume of the lungs receiving at least 20 Gy (lung V{sub 20}). Statistical significance was tested using Wilcoxon signed rank test at the significance level of 0.05. Overall, small differences were found in all dosimetric matrices at all rotational offsets: 95.6% of differences were < 1% or < 1 Gy. Of all rotational offsets, largest change in PTV V{sub 100%}, PTV D{sub max}, cord D{sub 0.35} {sub cc}, esophagus D{sub 0.35} {sub cc}, esophagus D{sub 5} {sub cc}, and lung V{sub 20} was − 8.36%, − 6.06%, 11.96%, 8.66%, 6.02%, and − 0.69%, respectively. No significant correlation was found between any dosimetric change and tumor-to-cord/esophagus distances (R{sup 2} range: 0 to 0.44). Larger dosimetric changes and intersubject variations were observed at larger rotational offsets. Small dosimetric differences were found owing to rotational offsets up to 5° in lung SBRT for medially located tumors. Larger intersubject variations were observed at larger rotational offsets.

  10. Dosimetric predictors of hypothyroidism in oropharyngeal cancer patients treated with intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Chyan, Arthur; Chen, Josephine; Shugard, Erin; Lambert, Louise; Quivey, Jeanne M; Yom, Sue S

    2014-01-01

    Radiation to the neck has long been associated with an elevated risk of hypothyroidism development. The goal of the present work is to define dosimetric predictors of hypothyroidism in oropharyngeal cancer (OPC) patients treated with intensity-modulated radiation therapy. Data for 123 patients, with a median follow up of 4.6 years, were retrospectively analyzed. Patients with elevated thyroid-stimulating hormone levels or with a clinical diagnosis were categorized as hypothyroid. Patient demographic parameters, thyroid volume, mean thyroid dose, the percent of thyroid volume receiving minimum specified dose levels (VxxGy), and the absolute thyroid volume spared from specified dose levels (VSxxGy) were analyzed. Normal-tissue complication probability (NTCP) was also calculated using several recently published models. Thyroid volume and many radiation dosimetric parameters were statistically different in the hypothyroid group. For the patients with initial thyroid volumes of 8 cc or greater, several dosimetric parameters were found to define subgroups at statistically significant lower risk of developing hypothyroidism. Patients with VS45 Gy of at least 3 cc, VS50 Gy at least 5 cc, VS50 Gy at least 6 cc, V50 Gy below 45%, V50 Gy below 55%, or mean thyroid dose below 49 Gy had a 28-38% estimated risk of hypothyroidism at 3 years compared to a 55% risk for the entire study group. Patients with a NTCP of less than 0.75 or 0.8, calculated using recently published models, were also observed to have a lower risk of developing hypothyroidism. Based on long-term follow up data for OPC patients treated with IMRT, we recommend plan optimization objectives to reduce the volume of thyroid receiving over 45 Gy to significantly decrease the risk of developing hypothyroidism. The online version of this article (doi:10.1186/s13014-014-0269-4) contains supplementary material, which is available to authorized users

  11. A Dosimetric Comparison of Tomotherapy and Volumetric Modulated Arc Therapy in the Treatment of High-Risk Prostate Cancer With Pelvic Nodal Radiation Therapy

    International Nuclear Information System (INIS)

    Pasquier, David; Cavillon, Fabrice; Lacornerie, Thomas; Touzeau, Claire; Tresch, Emmanuelle; Lartigau, Eric

    2013-01-01

    Purpose: To compare the dosimetric results of volumetric modulated arc therapy (VMAT) and helical tomotherapy (HT) in the treatment of high-risk prostate cancer with pelvic nodal radiation therapy. Methods and Materials: Plans were generated for 10 consecutive patients treated for high-risk prostate cancer with prophylactic whole pelvic radiation therapy (WPRT) using VMAT and HT. After WPRT, a sequential boost was delivered to the prostate. Plan quality was assessed according to the criteria of the International Commission on Radiation Units and Measurements 83 report: the near-minimal (D98%), near-maximal (D2%), and median (D50%) doses; the homogeneity index (HI); and the Dice similarity coefficient (DSC). Beam-on time, integral dose, and several organs at risk (OAR) dosimetric indexes were also compared. Results: For WPRT, HT was able to provide a higher D98% than VMAT (44.3 ± 0.3 Gy and 43.9 ± 0.5 Gy, respectively; P=.032) and a lower D2% than VMAT (47.3 ± 0.3 Gy and 49.1 ± 0.7 Gy, respectively; P=.005), leading to a better HI. The DSC was better for WPRT with HT (0.89 ± 0.009) than with VMAT (0.80 ± 0.02; P=.002). The dosimetric indexes for the prostate boost did not differ significantly. VMAT provided better rectum wall sparing at higher doses (V70, V75, D2%). Conversely, HT provided better bladder wall sparing (V50, V60, V70), except at lower doses (V20). The beam-on times for WPRT and prostate boost were shorter with VMAT than with HT (3.1 ± 0.1 vs 7.4 ± 0.6 min, respectively; P=.002, and 1.5 ± 0.05 vs 3.7 ± 0.3 min, respectively; P=.002). The integral dose was slightly lower for VMAT. Conclusion: VMAT and HT provided very similar and highly conformal plans that complied well with OAR dose-volume constraints. Although some dosimetric differences were statistically significant, they remained small. HT provided a more homogeneous dose distribution, whereas VMAT enabled a shorter delivery time.

  12. A dosimetric comparison of tomotherapy and volumetric modulated arc therapy in the treatment of high-risk prostate cancer with pelvic nodal radiation therapy.

    Science.gov (United States)

    Pasquier, David; Cavillon, Fabrice; Lacornerie, Thomas; Touzeau, Claire; Tresch, Emmanuelle; Lartigau, Eric

    2013-02-01

    To compare the dosimetric results of volumetric modulated arc therapy (VMAT) and helical tomotherapy (HT) in the treatment of high-risk prostate cancer with pelvic nodal radiation therapy. Plans were generated for 10 consecutive patients treated for high-risk prostate cancer with prophylactic whole pelvic radiation therapy (WPRT) using VMAT and HT. After WPRT, a sequential boost was delivered to the prostate. Plan quality was assessed according to the criteria of the International Commission on Radiation Units and Measurements 83 report: the near-minimal (D98%), near-maximal (D2%), and median (D50%) doses; the homogeneity index (HI); and the Dice similarity coefficient (DSC). Beam-on time, integral dose, and several organs at risk (OAR) dosimetric indexes were also compared. For WPRT, HT was able to provide a higher D98% than VMAT (44.3 ± 0.3 Gy and 43.9 ± 0.5 Gy, respectively; P=.032) and a lower D2% than VMAT (47.3 ± 0.3 Gy and 49.1 ± 0.7 Gy, respectively; P=.005), leading to a better HI. The DSC was better for WPRT with HT (0.89 ± 0.009) than with VMAT (0.80 ± 0.02; P=.002). The dosimetric indexes for the prostate boost did not differ significantly. VMAT provided better rectum wall sparing at higher doses (V70, V75, D2%). Conversely, HT provided better bladder wall sparing (V50, V60, V70), except at lower doses (V20). The beam-on times for WPRT and prostate boost were shorter with VMAT than with HT (3.1 ± 0.1 vs 7.4 ± 0.6 min, respectively; P=.002, and 1.5 ± 0.05 vs 3.7 ± 0.3 min, respectively; P=.002). The integral dose was slightly lower for VMAT. VMAT and HT provided very similar and highly conformal plans that complied well with OAR dose-volume constraints. Although some dosimetric differences were statistically significant, they remained small. HT provided a more homogeneous dose distribution, whereas VMAT enabled a shorter delivery time. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. Design and development of spine phantom to verify dosimetric accuracy of stereotactic body radiation therapy using 3D prnter

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seu Ran; Lee, Min Young; Kim, Min Joo; Park, So Hyun; Song Ji Hye; Suh, Tae Suk [Dept. of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of); Sohn, Jason W. [Dept. of Radiation Oncology, College of Medicine, Case Western Reserve University, Cleveland (United States)

    2015-10-15

    The purpose of this study is to verify dosimetric accuracy of delivered dose in spine SBRT as highly precise radiotherapy depending on cancer position using dedicated spine phantom based on 3D printer. Radiation therapy oncology group (RTOG) 0631 suggest different planning method in spine stereotactic body radiation therapy (SBRT) according to location of cancer owing to its distinct shape. The developed phantom especially using DLP method can be utilized as spine SBRT dosimetry research. Our study was able to confirm that the phantom was indeed similar with HU value of human spine as well as its shape.

  14. Dosimetric evaluation of the interplay effect in respiratory-gated RapidArc radiation therapy

    International Nuclear Information System (INIS)

    Riley, Craig; Yang, Yong; Li, Tianfang; Zhang, Yongqian; Heron, Dwight E.; Huq, M. Saiful

    2014-01-01

    Purpose: Volumetric modulated arc therapy (VMAT) with gating capability has had increasing adoption in many clinics in the United States. In this new technique, dose rate, gantry rotation speed, and the leaf motion speed of multileaf collimators (MLCs) are modulated dynamically during gated beam delivery to achieve highly conformal dose coverage of the target and normal tissue sparing. Compared with the traditional gated intensity-modulated radiation therapy technique, this complicated beam delivery technique may result in larger dose errors due to the intrafraction tumor motion. The purpose of this work is to evaluate the dosimetric influence of the interplay effect for the respiration-gated VMAT technique (RapidArc, Varian Medical Systems, Palo Alto, CA). Our work consisted of two parts: (1) Investigate the interplay effect for different target residual errors during gated RapidArc delivery using a one-dimensional moving phantom capable of producing stable sinusoidal movement; (2) Evaluate the dosimetric influence in ten clinical patients’ treatment plans using a moving phantom driven with a patient-specific respiratory curve. Methods: For the first part of this study, four plans were created with a spherical target for varying residual motion of 0.25, 0.5, 0.75, and 1.0 cm. Appropriate gating windows were applied for each. The dosimetric effect was evaluated using EDR2 film by comparing the gated delivery with static delivery. For the second part of the project, ten gated lung stereotactic body radiotherapy cases were selected and reoptimized to be delivered by the gated RapidArc technique. These plans were delivered to a phantom, and again the gated treatments were compared to static deliveries by the same methods. Results: For regular sinusoidal motion, the dose delivered to the target was not substantially affected by the gating windows when evaluated with the gamma statistics, suggesting the interplay effect has a small role in respiratory-gated Rapid

  15. Dosimetric evaluation of the interplay effect in respiratory-gated RapidArc radiation therapy.

    Science.gov (United States)

    Riley, Craig; Yang, Yong; Li, Tianfang; Zhang, Yongqian; Heron, Dwight E; Huq, M Saiful

    2014-01-01

    Volumetric modulated arc therapy (VMAT) with gating capability has had increasing adoption in many clinics in the United States. In this new technique, dose rate, gantry rotation speed, and the leaf motion speed of multileaf collimators (MLCs) are modulated dynamically during gated beam delivery to achieve highly conformal dose coverage of the target and normal tissue sparing. Compared with the traditional gated intensity-modulated radiation therapy technique, this complicated beam delivery technique may result in larger dose errors due to the intrafraction tumor motion. The purpose of this work is to evaluate the dosimetric influence of the interplay effect for the respiration-gated VMAT technique (RapidArc, Varian Medical Systems, Palo Alto, CA). Our work consisted of two parts: (1) Investigate the interplay effect for different target residual errors during gated RapidArc delivery using a one-dimensional moving phantom capable of producing stable sinusoidal movement; (2) Evaluate the dosimetric influence in ten clinical patients' treatment plans using a moving phantom driven with a patient-specific respiratory curve. For the first part of this study, four plans were created with a spherical target for varying residual motion of 0.25, 0.5, 0.75, and 1.0 cm. Appropriate gating windows were applied for each. The dosimetric effect was evaluated using EDR2 film by comparing the gated delivery with static delivery. For the second part of the project, ten gated lung stereotactic body radiotherapy cases were selected and reoptimized to be delivered by the gated RapidArc technique. These plans were delivered to a phantom, and again the gated treatments were compared to static deliveries by the same methods. For regular sinusoidal motion, the dose delivered to the target was not substantially affected by the gating windows when evaluated with the gamma statistics, suggesting the interplay effect has a small role in respiratory-gated RapidArc therapy. Varied results were

  16. Dosimetric verification for primary focal hypermetabolism of nasopharyngeal carcinoma patients treated with dynamic intensity-modulated radiation therapy.

    Science.gov (United States)

    Xin, Yong; Wang, Jia-Yang; Li, Liang; Tang, Tian-You; Liu, Gui-Hong; Wang, Jian-She; Xu, Yu-Mei; Chen, Yong; Zhang, Long-Zhen

    2012-01-01

    To make sure the feasibility with (18F)FDG PET/CT to guided dynamic intensity-modulated radiation therapy (IMRT) for nasopharyngeal carcinoma patients, by dosimetric verification before treatment. Chose 11 patients in III~IVA nasopharyngeal carcinoma treated with functional image-guided IMRT and absolute and relative dosimetric verification by Varian 23EX LA, ionization chamber, 2DICA of I'mRT Matrixx and IBA detachable phantom. Drawing outline and making treatment plan were by different imaging techniques (CT and (18F)FDG PET/CT). The dose distributions of the various regional were realized by SMART. The absolute mean errors of interest area were 2.39%±0.66 using 0.6 cc ice chamber. Results using DTA method, the average relative dose measurements within our protocol (3%, 3 mm) were 87.64% at 300 MU/min in all filed. Dosimetric verification before IMRT is obligatory and necessary. Ionization chamber and 2DICA of I'mRT Matrixx was the effective dosimetric verification tool for primary focal hyper metabolism in functional image-guided dynamic IMRT for nasopharyngeal carcinoma. Our preliminary evidence indicates that functional image-guided dynamic IMRT is feasible.

  17. Dosimetric comparison of intensity modulated radiation, Proton beam therapy and proton arc therapy for para-aortic lymph node tumor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Hoon [Dept. of Radiation Oncology, Konyang University Hospital. Daejeon (Korea, Republic of)

    2014-12-15

    To test feasibility of proton arc therapy (PAT) in the treatment of para-aortic lymph node tumor and compare its dosimetric properties with advanced radiotherapy techniques such as intensity modulated radiation therapy (IMRT) and conventional 3D conformal proton beam therapy (PBT). The treatment plans for para-aortic lymph node tumor were planned for 9 patients treated at our institution using IMRT, PBT, and PAT. Feasibility test and dosimetric evaluation were based on comparisons of dose volume histograms (DVHs) which reveal mean dose, D{sub 30%}, D{sub 60%}, D{sub 90%}, V{sub 30%}, V{sub 60%}, V{sub 90}%, organ equivalent doses (OEDs), normal tissue complication probability (NTCP), homogeneity index (HI) and conformity index (CI). The average doses delivered by PAT to the liver, kidney, small bowel, duodenum, stomach were 7.6%, 3%, 17.3%, 26.7%, and 14.4%, of the prescription dose (PD), respectively, which is higher than the doses delivered by IMRT (0.4%, 7.2%, 14.2%, 15.9%, and 12.8%, respectively) and PBT (4.9%, 0.5%, 14.12%, 16.1% 9.9%, respectively). The average homogeneity index and conformity index of tumor using PAT were 12.1 and 1.21, respectively which were much better than IMRT (21.5 and 1.47, respectively) and comparable to PBT (13.1 and 1.23, respectively). The result shows that both NTCP and OED of PAT are generally lower than IMRT and PBT. This study demonstrates that PAT is better in target conformity and homogeneity than IMRT and PBT but worse than IMRT and PBT for most of dosimetric factor which indicate that PAT is not recommended for the treatment of para-aortic lymph node tumor.

  18. Multibeam radiation therapy treatment application

    International Nuclear Information System (INIS)

    Manens, J.P.; Le Gall, G.; Chenal, C.; Ben Hassel, M.; Fresne, F.; Barillot, C.; Gibaud, B.; Lemoine, D.; Bouliou, A.; Scarabin, J.M.

    1991-01-01

    A software package has been developed for multibeam radiation therapy treatment application. We present in this study a computer-assisted dosimetric planning procedure which includes: i), an analytical stage for setting up the large volume via 2D and 3D displays; ii), a planning stage for issue of a treatment strategy including dosimetric simulations; and iii), a treatment stage to drive the target volume to the radiation unit isocenter. The combined use of stereotactic methods and multimodality imagery ensures spatial coherence and makes target definition and cognition of structure environment more accurate. The dosimetric planning suited to the spatial reference (the stereotactic frame) guarantees optimal distribution of the dose, computed by the original 3D volumetric algorithm. A computer-driven chair-framework cluster was designed to position the target volume at the radiation unit isocenter [fr

  19. Dosimetric analysis of imaging changes following pulmonary stereotactic body radiation therapy.

    Science.gov (United States)

    Prendergast, Brendan M; Bonner, James A; Popple, Richard A; Spencer, Sharon A; Fiveash, John B; Keene, Kimberly S; Cerfolio, Robert J; Minnich, Douglas J; Dobelbower, Michael C

    2011-02-01

    The aim of this study was to determine whether late patterns of pulmonary fibrosis are related to specific radiation doses administered during thoracic stereotactic body radiation therapy (SBRT). The records of all patients treated with SBRT for either pulmonary metastases or inoperable primary lung tumours at the University of Alabama at Birmingham from November 2005 to July 2008 were reviewed. Patients selected for analysis had diagnostic chest computed tomography (CT) scans acquired at least 180 days after completion of therapy. CT scans acquired at follow-up were co-registered with the original treatment planning CT scans for 12 eligible patients (17 lesions), and late-occurring pulmonary imaging abnormalities (IAs) were contoured. Dosimetric parameters analysed include D(80) , D(90) , V(18) and V(prescription dose) of the IA and V(14) and V(18) of the lung. Late pulmonary IAs were identified in 11 treated areas from nine patients. Late IAs could not be identified in six treated areas from three patients secondary to emphysema, tumour progression and severe atelectasis, respectively. The mean doses to 80% (D(80) ) and 90% (D(90) ) of the IAs were 18.4 and 14.5 Gy, respectively (ranges: 5.6-27.8 and 3.3-22.4 Gy). On average, 79.4% (range: 45.6-97.5%) of the IA received at least 18 Gy, while an average of 19.3% (range: 0.2-42.2%) received the prescription dose. On average, only 4.2% (range: 1.1-7.8%) of the lungs received 18 Gy. Imaging abnormalities consistent with pulmonary fibrosis are common after SBRT and are well approximated by the 18 Gy isodose distribution. The clinical ramification of these findings should be evaluated in future studies. © 2011 The Authors. Journal of Medical Imaging and Radiation Oncology © 2011 The Royal Australian and New Zealand College of Radiologists.

  20. Three-Dimensional Dosimetric Validation of a Magnetic Resonance Guided Intensity Modulated Radiation Therapy System

    Energy Technology Data Exchange (ETDEWEB)

    Rankine, Leith J., E-mail: Leith_Rankine@med.unc.edu [Department of Radiation Oncology, Washington University School of Medicine, St Louis, Missouri (United States); Department of Radiation Oncology, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina (United States); Mein, Stewart [Medical Physics Graduate Program, Duke University, Durham, North Carolina (United States); Cai, Bin; Curcuru, Austen [Department of Radiation Oncology, Washington University School of Medicine, St Louis, Missouri (United States); Juang, Titania; Miles, Devin [Medical Physics Graduate Program, Duke University, Durham, North Carolina (United States); Mutic, Sasa; Wang, Yuhe [Department of Radiation Oncology, Washington University School of Medicine, St Louis, Missouri (United States); Oldham, Mark [Medical Physics Graduate Program, Duke University, Durham, North Carolina (United States); Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States); Li, H. Harold, E-mail: hli@radonc.wustl.edu [Department of Radiation Oncology, Washington University School of Medicine, St Louis, Missouri (United States)

    2017-04-01

    Purpose: To validate the dosimetric accuracy of a commercially available magnetic resonance guided intensity modulated radiation therapy (MRgIMRT) system using a hybrid approach: 3-dimensional (3D) measurements and Monte Carlo calculations. Methods and Materials: We used PRESAGE radiochromic plastic dosimeters with remote optical computed tomography readout to perform 3D high-resolution measurements, following a novel remote dosimetry protocol. We followed the intensity modulated radiation therapy commissioning recommendations of American Association of Physicists in Medicine Task Group 119, adapted to incorporate 3D data. Preliminary tests (“AP” and “3D-Bands”) were delivered to 9.5-cm usable diameter cylindrical PRESAGE dosimeters to validate the treatment planning system (TPS) for nonmodulated deliveries; assess the sensitivity, uniformity, and rotational symmetry of the PRESAGE dosimeters; and test the robustness of the remote dosimetry protocol. Following this, 4 clinical MRgIMRT plans (“MultiTarget,” “Prostate,” “Head/Neck,” and “C-Shape”) were measured using 13-cm usable diameter PRESAGE dosimeters. For all plans, 3D-γ (3% or 3 mm global, 10% threshold) passing rates were calculated and 3D-γ maps were examined. Point doses were measured with an IBA-CC01 ionization chamber for validation of absolute dose. Finally, by use of an in-house-developed, GPU-accelerated Monte Carlo algorithm (gPENELOPE), we independently calculated dose for all 6 Task Group 119 plans and compared against the TPS. Results: For PRESAGE measurements, 3D-γ analysis yielded passing rates of 98.7%, 99.2%, 98.5%, 98.0%, 99.2%, and 90.7% for AP, 3D-Bands, MultiTarget, Prostate, Head/Neck, and C-Shape, respectively. Ion chamber measurements were within an average of 0.5% (±1.1%) from the TPS dose. Monte Carlo calculations demonstrated good agreement with the TPS, with a mean 3D-γ passing rate of 98.5% ± 1.9% using a stricter 2%/2-mm criterion. Conclusions: We

  1. Three-Dimensional Dosimetric Validation of a Magnetic Resonance Guided Intensity Modulated Radiation Therapy System

    International Nuclear Information System (INIS)

    Rankine, Leith J.; Mein, Stewart; Cai, Bin; Curcuru, Austen; Juang, Titania; Miles, Devin; Mutic, Sasa; Wang, Yuhe; Oldham, Mark; Li, H. Harold

    2017-01-01

    Purpose: To validate the dosimetric accuracy of a commercially available magnetic resonance guided intensity modulated radiation therapy (MRgIMRT) system using a hybrid approach: 3-dimensional (3D) measurements and Monte Carlo calculations. Methods and Materials: We used PRESAGE radiochromic plastic dosimeters with remote optical computed tomography readout to perform 3D high-resolution measurements, following a novel remote dosimetry protocol. We followed the intensity modulated radiation therapy commissioning recommendations of American Association of Physicists in Medicine Task Group 119, adapted to incorporate 3D data. Preliminary tests (“AP” and “3D-Bands”) were delivered to 9.5-cm usable diameter cylindrical PRESAGE dosimeters to validate the treatment planning system (TPS) for nonmodulated deliveries; assess the sensitivity, uniformity, and rotational symmetry of the PRESAGE dosimeters; and test the robustness of the remote dosimetry protocol. Following this, 4 clinical MRgIMRT plans (“MultiTarget,” “Prostate,” “Head/Neck,” and “C-Shape”) were measured using 13-cm usable diameter PRESAGE dosimeters. For all plans, 3D-γ (3% or 3 mm global, 10% threshold) passing rates were calculated and 3D-γ maps were examined. Point doses were measured with an IBA-CC01 ionization chamber for validation of absolute dose. Finally, by use of an in-house-developed, GPU-accelerated Monte Carlo algorithm (gPENELOPE), we independently calculated dose for all 6 Task Group 119 plans and compared against the TPS. Results: For PRESAGE measurements, 3D-γ analysis yielded passing rates of 98.7%, 99.2%, 98.5%, 98.0%, 99.2%, and 90.7% for AP, 3D-Bands, MultiTarget, Prostate, Head/Neck, and C-Shape, respectively. Ion chamber measurements were within an average of 0.5% (±1.1%) from the TPS dose. Monte Carlo calculations demonstrated good agreement with the TPS, with a mean 3D-γ passing rate of 98.5% ± 1.9% using a stricter 2%/2-mm criterion. Conclusions: We

  2. Dosimetric analysis of radiation sources for use dermatological lesions

    International Nuclear Information System (INIS)

    Tada, Ariane

    2010-01-01

    Skin lesions undergoing therapy with radiation sources may have different patterns of malignancy. Malignant lesions or cancer most commonly found in radiotherapy services are carcinomas. Radiation therapy in skin lesions is performed with low penetration beams and orthovoltage X-rays, electron beams and radioactive sources ( 192 Ir, 198 Au, e 90 Sr) arranged on a surface mold or in metal applicator. This study aims to analyze the therapeutic radiation dose profile produced by radiation sources used in skin lesions radiotherapy procedures . Experimental measurements for the analysis of dosimetric radiation sources were compared with calculations obtained from a computer system based on the Monte Carlo Method. Computational results had a good agreement with the experimental measurements. Experimental measurements and computational results by the MCNP4C code were both physically consistent as expected. These experimental measurements compared with calculations using the MCNP-4C code have been used to validate the calculations obtained by MCNP code and to provide a reliable medical application for each clinical case. (author)

  3. Examination of geometric and dosimetric accuracies of gated step-and-shoot intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Wiersma, R. D.; Xing, L.

    2007-01-01

    Due to the complicated technical nature of gated radiation therapy, electronic and mechanical limitations may affect the precision of delivery. The purpose of this study is to investigate the geometric and dosimetric accuracies of gated step-and-shoot intensity modulated radiation treatments (SS-IMRT). Unique segmental MLC plans are designed, which allow quantitative testing of the gating process. Both ungated and gated deliveries are investigated for different dose sizes, dose rates, and gating window times using a commercial treatment system (Varian Trilogy) together with a respiratory gating system [Varian Real-Time Position Management system]. Radiographic film measurements are used to study the geometric accuracy, where it is found that with both ungated and gated SS-IMRT deliveries the MLC leaf divergence away from planned is less than or equal to the MLC specified leaf tolerance value for all leafs (leaf tolerance being settable from 0.5-5 mm). Nevertheless, due to the MLC controller design, failure to define a specific leaf tolerance value suitable to the SS-IMRT plan can lead to undesired geometric effects, such as leaf motion of up to the maximum 5 mm leaf tolerance value occurring after the beam is turned on. In this case, gating may be advantageous over the ungated case, as it allows more time for the MLC to reach the intended leaf configuration. The dosimetric precision of gated SS-IMRT is investigated using ionization chamber methods. Compared with the ungated case, it is found that gating generally leads to increased dosimetric errors due to the interruption of the ''overshoot phenomena.'' With gating the average timing deviation for intermediate segments is found to be 27 ms, compared to 18 ms for the ungated case. For a plan delivered at 600 MU/min this would correspond to an average segment dose error of ∼0.27 MU and ∼0.18 MU for gated and ungated deliveries, respectively. The maximum dosimetric errors for individual intermediate segments are

  4. Stereotactic body radiation therapy planning with duodenal sparing using volumetric-modulated arc therapy vs intensity-modulated radiation therapy in locally advanced pancreatic cancer: A dosimetric analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Rachit; Wild, Aaron T.; Ziegler, Mark A.; Hooker, Ted K.; Dah, Samson D.; Tran, Phuoc T.; Kang, Jun; Smith, Koren; Zeng, Jing [Department of Radiation Oncology and Molecular Radiation Sciences, Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins Hospital, 401N. Broadway, Weinberg Suite 1440, Baltimore, MD 21231 (United States); Pawlik, Timothy M. [Department of Surgery, Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, MD (United States); Tryggestad, Erik [Department of Radiation Oncology and Molecular Radiation Sciences, Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins Hospital, 401N. Broadway, Weinberg Suite 1440, Baltimore, MD 21231 (United States); Ford, Eric [Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, Seattle, WA (United States); Herman, Joseph M., E-mail: jherma15@jhmi.edu [Department of Radiation Oncology and Molecular Radiation Sciences, Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins Hospital, 401N. Broadway, Weinberg Suite 1440, Baltimore, MD 21231 (United States)

    2013-10-01

    Stereotactic body radiation therapy (SBRT) achieves excellent local control for locally advanced pancreatic cancer (LAPC), but may increase late duodenal toxicity. Volumetric-modulated arc therapy (VMAT) delivers intensity-modulated radiation therapy (IMRT) with a rotating gantry rather than multiple fixed beams. This study dosimetrically evaluates the feasibility of implementing duodenal constraints for SBRT using VMAT vs IMRT. Non–duodenal sparing (NS) and duodenal-sparing (DS) VMAT and IMRT plans delivering 25 Gy in 1 fraction were generated for 15 patients with LAPC. DS plans were constrained to duodenal D{sub max} of<30 Gy at any point. VMAT used 1 360° coplanar arc with 4° spacing between control points, whereas IMRT used 9 coplanar beams with fixed gantry positions at 40° angles. Dosimetric parameters for target volumes and organs at risk were compared for DS planning vs NS planning and VMAT vs IMRT using paired-sample Wilcoxon signed rank tests. Both DS VMAT and DS IMRT achieved significantly reduced duodenal D{sub mean}, D{sub max}, D{sub 1cc}, D{sub 4%}, and V{sub 20} {sub Gy} compared with NS plans (all p≤0.002). DS constraints compromised target coverage for IMRT as demonstrated by reduced V{sub 95%} (p = 0.01) and D{sub mean} (p = 0.02), but not for VMAT. DS constraints resulted in increased dose to right kidney, spinal cord, stomach, and liver for VMAT. Direct comparison of DS VMAT and DS IMRT revealed that VMAT was superior in sparing the left kidney (p<0.001) and the spinal cord (p<0.001), whereas IMRT was superior in sparing the stomach (p = 0.05) and the liver (p = 0.003). DS VMAT required 21% fewer monitor units (p<0.001) and delivered treatment 2.4 minutes faster (p<0.001) than DS IMRT. Implementing DS constraints during SBRT planning for LAPC can significantly reduce duodenal point or volumetric dose parameters for both VMAT and IMRT. The primary consequence of implementing DS constraints for VMAT is increased dose to other organs at

  5. The features of radiation induced lung fibrosis related with dosimetric parameters

    International Nuclear Information System (INIS)

    Oh, Young-Taek; Noh, O Kyu; Jang, Hyunsoo; Chun, Mison; Park, Kyung Joo; Park, Kwang Joo; Kim, Mi-Hwa; Park, Hae-Jin

    2012-01-01

    Background and purpose: Radiation induced lung fibrosis (RILF) is a major complication after lung irradiation and is very important for long term quality of life and could result in fatal respiratory insufficiency. However, there has been little information on dosimetric parameters for radiotherapy planning in the aspect of RILF. The features of RILF related with dosimetric parameters were evaluated. Methods and materials: Forty-eight patients with non-small cell lung carcinoma who underwent post-operative radiation therapy (PORT) without adjuvant chemotherapy were analyzed. The degree of lung fibrosis was estimated by fibrosis volume and the dosimetric parameters were calculated from the plan of 3-dimensional conformal radiotherapy. Results: The fibrosis volume and V-dose as dosimetric parameters showed significant correlation and the correlation coefficient ranged from 0.602 to 0.683 (P < 0.01). The degree of the correlation line was steeper as the dose increase and threshold dose was not found. Mean lung dose (MLD) showed strong correlation with fibrosis volume (correlation coefficient = 0.726, P < 0.01). Conclusions: The fibrosis volume is continuously increased with V-dose as the reference dose increases. MLD is useful as a single parameter for comparing rival plans in the aspect of RILF.

  6. Dosimetric analysis of radiation sources to use in dermatological lesions

    International Nuclear Information System (INIS)

    Tada, Ariane

    2010-01-01

    Skin lesions undergoing therapy with radiation sources may have different patterns of malignancy. Malignant lesions or cancer most commonly found in radiotherapy services are carcinomas. Radiation therapy in skin lesions is performed with low penetration beams and orthovoltage X-rays, electron beams and radioactive sources ( 192 Ir, 198 Au, e 90 Sr) arranged on a surface mold or in metal applicator. This study aims to analyze the therapeutic radiation dose profile produced by radiation sources used in skin lesions radiotherapy procedures. Experimental measurements for the analysis of dosimetric radiation sources were compared with calculations obtained from a computer system based on the Monte Carlo Method. Computational results had a good agreement with the experimental measurements. Experimental measurements and computational results by the MCNP4C code have been used to validate the calculations obtained by MCNP code and to provide a reliable medical application for each clinical case. (author)

  7. Dosimetric Predictors of Duodenal Toxicity After Intensity Modulated Radiation Therapy for Treatment of the Para-aortic Nodes in Gynecologic Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Verma, Jonathan [Department of Radiation Oncology, University of Miami Miller School of Medicine, Miami, Florida (United States); Sulman, Erik P.; Jhingran, Anuja [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Tucker, Susan L. [Department of Bioinformatics and Computational Biology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Rauch, Gaiane M. [Department of Radiology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Eifel, Patricia J. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Klopp, Ann H., E-mail: aklopp@mdanderson.org [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States)

    2014-02-01

    Purpose: To determine the incidence of duodenal toxicity in patients receiving intensity modulated radiation therapy (IMRT) for treatment of para-aortic nodes and to identify dosimetric parameters predictive of late duodenal toxicity. Methods and Materials: We identified 105 eligible patients with gynecologic malignancies who were treated with IMRT for gross metastatic disease in the para-aortic nodes from January 1, 2005, through December 31, 2009. Patients were treated to a nodal clinical target volume to 45 to 50.4 Gy with a boost to 60 to 66 Gy. The duodenum was contoured, and dosimetric data were exported for analysis. Duodenal toxicity was scored according to Radiation Therapy Oncology Group criteria. Univariate Cox proportional hazards analysis and recursive partitioning analysis were used to determine associations between dosimetric variables and time to toxicity and to identify the optimal threshold that separated patients according to risk of toxicity. Results: Nine of the 105 patients experienced grade 2 to grade 5 duodenal toxicity, confirmed by endoscopy in all cases. The 3-year actuarial rate of any duodenal toxicity was 11.7%. A larger volume of the duodenum receiving 55 Gy (V55) was associated with higher rates of duodenal toxicity. The 3-year actuarial rates of duodenal toxicity with V55 above and below 15 cm{sup 3} were 48.6% and 7.4%, respectively (P<.01). In Cox univariate analysis of dosimetric variables, V55 was associated with duodenal toxicity (P=.029). In recursive partitioning analysis, V55 less than 13.94% segregated all patients with duodenal toxicity. Conclusions: Dose-escalated IMRT can safely and effectively treat para-aortic nodal disease in gynecologic malignancies, provided that care is taken to limit the dose to the duodenum to reduce the risk of late duodenal toxicity. Limiting V55 to below 15 cm{sup 3} may reduce the risk of duodenal complications. In cases where the treatment cannot be delivered within these constraints

  8. A comprehensive dosimetric study of pancreatic cancer treatment using three-dimensional conformal radiation therapy (3DCRT), intensity-modulated radiation therapy (IMRT), volumetric-modulated radiation therapy (VMAT), and passive-scattering and modulated-scanning proton therapy (PT)

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Xuanfeng; Dionisi, Francesco; Tang, Shikui; Ingram, Mark; Hung, Chun-Yu; Prionas, Evangelos; Lichtenwalner, Phil; Butterwick, Ian; Zhai, Huifang; Yin, Lingshu; Lin, Haibo; Kassaee, Alireza; Avery, Stephen, E-mail: stephen.avery@uphs.upenn.edu

    2014-07-01

    With traditional photon therapy to treat large postoperative pancreatic target volume, it often leads to poor tolerance of the therapy delivered and may contribute to interrupted treatment course. This study was performed to evaluate the potential advantage of using passive-scattering (PS) and modulated-scanning (MS) proton therapy (PT) to reduce normal tissue exposure in postoperative pancreatic cancer treatment. A total of 11 patients with postoperative pancreatic cancer who had been previously treated with PS PT in University of Pennsylvania Roberts Proton Therapy Center from 2010 to 2013 were identified. The clinical target volume (CTV) includes the pancreatic tumor bed as well as the adjacent high-risk nodal areas. Internal (iCTV) was generated from 4-dimensional (4D) computed tomography (CT), taking into account target motion from breathing cycle. Three-field and 4-field 3D conformal radiation therapy (3DCRT), 5-field intensity-modulated radiation therapy, 2-arc volumetric-modulated radiation therapy, and 2-field PS and MS PT were created on the patients’ average CT. All the plans delivered 50.4 Gy to the planning target volume (PTV). Overall, 98% of PTV was covered by 95% of the prescription dose and 99% of iCTV received 98% prescription dose. The results show that all the proton plans offer significant lower doses to the left kidney (mean and V{sub 18} {sub Gy}), stomach (mean and V{sub 20} {sub Gy}), and cord (maximum dose) compared with all the photon plans, except 3-field 3DCRT in cord maximum dose. In addition, MS PT also provides lower doses to the right kidney (mean and V{sub 18} {sub Gy}), liver (mean dose), total bowel (V{sub 20} {sub Gy} and mean dose), and small bowel (V{sub 15} {sub Gy} absolute volume ratio) compared with all the photon plans and PS PT. The dosimetric advantage of PT points to the possibility of treating tumor bed and comprehensive nodal areas while providing a more tolerable treatment course that could be used for dose

  9. A comprehensive dosimetric study of pancreatic cancer treatment using three-dimensional conformal radiation therapy (3DCRT), intensity-modulated radiation therapy (IMRT), volumetric-modulated radiation therapy (VMAT), and passive-scattering and modulated-scanning proton therapy (PT)

    International Nuclear Information System (INIS)

    Ding, Xuanfeng; Dionisi, Francesco; Tang, Shikui; Ingram, Mark; Hung, Chun-Yu; Prionas, Evangelos; Lichtenwalner, Phil; Butterwick, Ian; Zhai, Huifang; Yin, Lingshu; Lin, Haibo; Kassaee, Alireza; Avery, Stephen

    2014-01-01

    With traditional photon therapy to treat large postoperative pancreatic target volume, it often leads to poor tolerance of the therapy delivered and may contribute to interrupted treatment course. This study was performed to evaluate the potential advantage of using passive-scattering (PS) and modulated-scanning (MS) proton therapy (PT) to reduce normal tissue exposure in postoperative pancreatic cancer treatment. A total of 11 patients with postoperative pancreatic cancer who had been previously treated with PS PT in University of Pennsylvania Roberts Proton Therapy Center from 2010 to 2013 were identified. The clinical target volume (CTV) includes the pancreatic tumor bed as well as the adjacent high-risk nodal areas. Internal (iCTV) was generated from 4-dimensional (4D) computed tomography (CT), taking into account target motion from breathing cycle. Three-field and 4-field 3D conformal radiation therapy (3DCRT), 5-field intensity-modulated radiation therapy, 2-arc volumetric-modulated radiation therapy, and 2-field PS and MS PT were created on the patients’ average CT. All the plans delivered 50.4 Gy to the planning target volume (PTV). Overall, 98% of PTV was covered by 95% of the prescription dose and 99% of iCTV received 98% prescription dose. The results show that all the proton plans offer significant lower doses to the left kidney (mean and V 18 Gy ), stomach (mean and V 20 Gy ), and cord (maximum dose) compared with all the photon plans, except 3-field 3DCRT in cord maximum dose. In addition, MS PT also provides lower doses to the right kidney (mean and V 18 Gy ), liver (mean dose), total bowel (V 20 Gy and mean dose), and small bowel (V 15 Gy absolute volume ratio) compared with all the photon plans and PS PT. The dosimetric advantage of PT points to the possibility of treating tumor bed and comprehensive nodal areas while providing a more tolerable treatment course that could be used for dose escalation and combining with radiosensitizing

  10. Dosimetric comparison of three intensity-modulated radiation therapies for left breast cancer after breast-conserving surgery.

    Science.gov (United States)

    Zhang, Huai-Wen; Hu, Bo; Xie, Chen; Wang, Yun-Lai

    2018-05-01

    This study aimed to evaluate dosimetric differences of intensity-modulated radiation therapy (IMRT) in target and normal tissues after breast-conserving surgery. IMRT five-field plan I, IMRT six-field plan II, and field-in-field-direct machine parameter optimization-IMRT plan III were designed for each of the 50 patients. One-way analysis of variance was performed to compare differences, and P mean dose (D mean ) for the heart (P optimization-IMRT plans III can reduce doses and volumes to the lungs and heart better while maintaining satisfying conformity index and homogeneity index of target. Nevertheless, plan II neglects target movements caused by respiration. In the same manner, plan III can substantially reduce MU and shorten patient treatment time. Therefore, plan III, which considers target movement caused by respiration, is a more practical radiation mode. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  11. Dosimetric impact of gastrointestinal air column in radiation treatment of pancreatic cancer.

    Science.gov (United States)

    Estabrook, Neil C; Corn, Jonathan B; Ewing, Marvene M; Cardenes, Higinia R; Das, Indra J

    2018-02-01

    Dosimetric evaluation of air column in gastrointestinal (GI) structures in intensity modulated radiation therapy (IMRT) of pancreatic cancer. Nine sequential patients were retrospectively chosen for dosimetric analysis of air column in the GI apparatus in pancreatic cancer using cone beam CT (CBCT). The four-dimensional CT (4DCT) was used for target and organs at risk (OARs) and non-coplanar IMRT was used for treatment. Once a week, these patients underwent CBCT for air filling, isocentre verification and dose calculations retrospectively. Abdominal air column variation was as great as ±80% between weekly CBCT and 4DCT. Even with such a large air column in the treatment path for pancreatic cancer, changes in anteroposterior dimension were minimal (2.8%). Using IMRT, variations in air column did not correlate dosimetrically with large changes in target volume. An average dosimetric deviation of mere -3.3% and a maximum of -5.5% was observed. CBCT revealed large air column in GI structures; however, its impact is minimal for target coverage. Because of the inherent advantage of segmentation in IMRT, where only a small fraction of a given beam passes through the air column, this technique might have an advantage over 3DCRT in treating upper GI malignancies where the daily air column can have significant impact. Advances in knowledge: Radiation treatment of pancreatic cancer has significant challenges due to positioning, imaging of soft tissues and variability of air column in bowels. The dosimetric impact of variable air column is retrospectively studied using CBCT. Even though, the volume of air column changes by ± 80%, its dosimetric impact in IMRT is minimum.

  12. Dosimetric Comparison of Real-Time MRI-Guided Tri-Cobalt-60 Versus Linear Accelerator-Based Stereotactic Body Radiation Therapy Lung Cancer Plans.

    Science.gov (United States)

    Wojcieszynski, Andrzej P; Hill, Patrick M; Rosenberg, Stephen A; Hullett, Craig R; Labby, Zacariah E; Paliwal, Bhudatt; Geurts, Mark W; Bayliss, R Adam; Bayouth, John E; Harari, Paul M; Bassetti, Michael F; Baschnagel, Andrew M

    2017-06-01

    Magnetic resonance imaging-guided radiation therapy has entered clinical practice at several major treatment centers. Treatment of early-stage non-small cell lung cancer with stereotactic body radiation therapy is one potential application of this modality, as some form of respiratory motion management is important to address. We hypothesize that magnetic resonance imaging-guided tri-cobalt-60 radiation therapy can be used to generate clinically acceptable stereotactic body radiation therapy treatment plans. Here, we report on a dosimetric comparison between magnetic resonance imaging-guided radiation therapy plans and internal target volume-based plans utilizing volumetric-modulated arc therapy. Ten patients with early-stage non-small cell lung cancer who underwent radiation therapy planning and treatment were studied. Following 4-dimensional computed tomography, patient images were used to generate clinically deliverable plans. For volumetric-modulated arc therapy plans, the planning tumor volume was defined as an internal target volume + 0.5 cm. For magnetic resonance imaging-guided plans, a single mid-inspiratory cycle was used to define a gross tumor volume, then expanded 0.3 cm to the planning tumor volume. Treatment plan parameters were compared. Planning tumor volumes trended larger for volumetric-modulated arc therapy-based plans, with a mean planning tumor volume of 47.4 mL versus 24.8 mL for magnetic resonance imaging-guided plans ( P = .08). Clinically acceptable plans were achievable via both methods, with bilateral lung V20, 3.9% versus 4.8% ( P = .62). The volume of chest wall receiving greater than 30 Gy was also similar, 22.1 versus 19.8 mL ( P = .78), as were all other parameters commonly used for lung stereotactic body radiation therapy. The ratio of the 50% isodose volume to planning tumor volume was lower in volumetric-modulated arc therapy plans, 4.19 versus 10.0 ( P guided tri-cobalt-60 radiation therapy is capable of delivering lung high

  13. SU-E-J-274: Responses of Medulloblastoma Cells to Radiation Dosimetric Parameters in Intensity-Modulated Radiation Therapy

    International Nuclear Information System (INIS)

    Park, J; Park, J; Rogalla, S; Contag, C; Woo, D; Lee, D; Park, H; Suh, T

    2015-01-01

    Purpose: To evaluate radiation responses of the medulloblastoma cell line Daoy in intensity-modulated radiation therapy (IMRT), quantitative variations to variable radiation dosimetic parameters were tracked by bioluminescent images (BLIs). Methods: The luciferase and green fluorescent protein positive Daoy cells were cultured on dishes. The medulloblastoma cells irradiated to different dose rate, interval of fractionated doses, field margin and misalignment, and dose uniformity in IMRT were monitored using bioluminescent images. The cultured cells were placed into a dedicated acrylic phantom to deliver intensity-modulated fluences and calculate accurate predicted dose distribution. The radiation with dose rate from 0.5 Gy/min to 15 Gy/min was irradiated by adjusting monitor unit per minute and source-to-surface distances. The intervals of fractionated dose delivery were changed considering the repair time of double strand breaks (DSB) revealed by straining of gamma-H2AX.The effect of non-uniform doses on the cells were visualized by registering dose distributions and BLIs. The viability according to dosimetric parameters was correlated with bioluminescent intensities for cross-check of radiation responses. Results: The DSB and cell responses due to the first fractionated dose delivery significantly affected final tumor control rather than other parameters. The missing tumor volumes due to the smaller field margin than the tumor periphery or field misalignment caused relapse of cell responses on BLIs. The dose rate and gradient had effect on initial responses but could not bring out the distinguishable killing effect on cancer cells. Conclusion: Visualized and quantified bioluminescent images were useful to correlate the dose distributions with spatial radiation effects on cells. This would derive the effective combination of dose delivery parameters and fractionation. Radiation responses in particular IMRT configuration could be reflected to image based-dose re-optimization

  14. Dosimetric quality control of treatment planning systems in external radiation therapy using Digital Test Objects calculated by PENELOPE Monte-Carlo simulations

    International Nuclear Information System (INIS)

    Ben Hdech, Yassine

    2011-01-01

    To ensure the required accuracy and prevent from mis-administration, cancer treatments, by external radiation therapy are simulated on Treatment Planning System or TPS before radiation delivery in order to ensure that the prescription is achieved both in terms of target volumes coverage and healthy tissues protection. The TPS calculates the patient dose distribution and the treatment time per beam required to deliver the prescribed dose. TPS is a key system in the decision process of treatment by radiation therapy. It is therefore essential that the TPS be subject to a thorough check of its performance (quality control or QC) and in particular its ability to accurately compute dose distributions for patients in all clinical situations that be met. The 'traditional' methods recommended to carry out dosimetric CQ of algorithms implemented in the TPS are based on comparisons between dose distributions calculated with the TPS and dose measured in physical test objects (PTO) using the treatment machine. In this thesis we propose to substitute the reference dosimetric measurements performed in OTP by benchmark dose calculations in Digital Test Objects using PENELOPE Monte-Carlo code. This method has three advantages: (i) it allows simulation in situations close to the clinic and often too complex to be experimentally feasible; (ii) due to the digital form of reference data the QC process may be automated; (iii) it allows a comprehensive TPS CQ without hindering the use of an equipment devoted primarily to patients treatments. This new method of CQ has been tested successfully on the Eclipse TPS from Varian Medical Systems Company. (author) [fr

  15. Predictors of Radiation Pneumonitis in Patients Receiving Intensity Modulated Radiation Therapy for Hodgkin and Non-Hodgkin Lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Pinnix, Chelsea C., E-mail: ccpinnix@mdanderson.org [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Smith, Grace L.; Milgrom, Sarah; Osborne, Eleanor M.; Reddy, Jay P.; Akhtari, Mani; Reed, Valerie; Arzu, Isidora; Allen, Pamela K.; Wogan, Christine F. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Fanale, Michele A.; Oki, Yasuhiro; Turturro, Francesco; Romaguera, Jorge; Fayad, Luis; Fowler, Nathan; Westin, Jason; Nastoupil, Loretta; Hagemeister, Fredrick B.; Rodriguez, M. Alma [Department of Lymphoma/Myeloma, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); and others

    2015-05-01

    Purpose: Few studies to date have evaluated factors associated with the development of radiation pneumonitis (RP) in patients with Hodgkin lymphoma (HL) and non-Hodgkin lymphoma (NHL), especially in patients treated with contemporary radiation techniques. These patients represent a unique group owing to the often large radiation target volumes within the mediastinum and to the potential to receive several lines of chemotherapy that add to pulmonary toxicity for relapsed or refractory disease. Our objective was to determine the incidence and clinical and dosimetric risk factors associated with RP in lymphoma patients treated with intensity modulated radiation therapy (IMRT) at a single institution. Methods and Materials: We retrospectively reviewed clinical charts and radiation records of 150 consecutive patients who received mediastinal IMRT for HL and NHL from 2009 through 2013. Clinical and dosimetric predictors associated with RP according to Radiation Therapy Oncology Group (RTOG) acute toxicity criteria were identified in univariate analysis using the Pearson χ{sup 2} test and logistic multivariate regression. Results: Mediastinal radiation was administered as consolidation therapy in 110 patients with newly diagnosed HL or NHL and in 40 patients with relapsed or refractory disease. The overall incidence of RP (RTOG grades 1-3) was 14% in the entire cohort. Risk of RP was increased for patients who received radiation for relapsed or refractory disease (25%) versus those who received consolidation therapy (10%, P=.019). Several dosimetric parameters predicted RP, including mean lung dose of >13.5 Gy, V{sub 20} of >30%, V{sub 15} of >35%, V{sub 10} of >40%, and V{sub 5} of >55%. The likelihood ratio χ{sup 2} value was highest for V{sub 5} >55% (χ{sup 2} = 19.37). Conclusions: In using IMRT to treat mediastinal lymphoma, all dosimetric parameters predicted RP, although small doses to large volumes of lung had the greatest influence. Patients with relapsed

  16. Dosimetric evaluation of a MOSFET detector for clinical application in photon therapy.

    Science.gov (United States)

    Kohno, Ryosuke; Hirano, Eriko; Nishio, Teiji; Miyagishi, Tomoko; Goka, Tomonori; Kawashima, Mitsuhiko; Ogino, Takashi

    2008-01-01

    Dosimetric characteristics of a metal oxide-silicon semiconductor field effect transistor (MOSFET) detector are studied with megavoltage photon beams for patient dose verification. The major advantages of this detector are its size, which makes it a point dosimeter, and its ease of use. In order to use the MOSFET detector for dose verification of intensity-modulated radiation therapy (IMRT) and in-vivo dosimetry for radiation therapy, we need to evaluate the dosimetric properties of the MOSFET detector. Therefore, we investigated the reproducibility, dose-rate effect, accumulated-dose effect, angular dependence, and accuracy in tissue-maximum ratio measurements. Then, as it takes about 20 min in actual IMRT for the patient, we evaluated fading effect of MOSFET response. When the MOSFETs were read-out 20 min after irradiation, we observed a fading effect of 0.9% with 0.9% standard error of the mean. Further, we applied the MOSFET to the measurement of small field total scatter factor. The MOSFET for dose measurements of small field sizes was better than the reference pinpoint chamber with vertical direction. In conclusion, we assessed the accuracy, reliability, and usefulness of the MOSFET detector in clinical applications such as pinpoint absolute dosimetry for small fields.

  17. The dosimetric control in radiotherapy

    International Nuclear Information System (INIS)

    Veres, A.

    2009-01-01

    The author first presents the thermoluminescent dosimetry method developed by the Equal-Estro Laboratory to control radiotherapy systems, according to which dosimeters are mailed by the radiotherapy centres to the laboratory, and then analyzed with respect to the level of dose bias. In a second part, he discusses the different techniques used for the dosimetric control of new radiotherapy methods (intensity-modulated radiation therapy, tomo-therapy) for which film dosimetry is applied. He also evokes the development of new phantoms and the development of a method for the dosimetric control of proton beams

  18. Computerized dosimetric system for studying radiation fields of afterloading apparatus

    International Nuclear Information System (INIS)

    Andryushin, O.S.; Gorshkov, M.I.

    1988-01-01

    Works on designing a computerized dosimetric scanner (CODOS) for studying radiation fields of remote therapeutic apparatus, providing dosimetric data input from semiconductor transducers and ionization chambers directly into the computer memory were carried out. The basic problems were to provide reproducibility and accuracy of the initial dosimetric data, formation of the data bank on LUEhV-15M1 accelerator bremsstrahlung and electron radiation fields. An extra problem was to provide isodose curves for manual scheduling of radiotherapy. The 15 VUMS-28-025 complex based on Elektronika-60 computer was chosen as a host computer, photodiodes were used as a semiconductor detector, the 70108 rod chamber and VA-J-18 dosemeters were used as an ionization chamber. The results of studies with the CODOS system have been shown that it meets the dosimetric requirements for therapeutic apparatus

  19. SU-E-T-300: Dosimetric Comparision of 4D Radiation Therapy and 3D Radiation Therapy for the Liver Tumor Based On 4D Medical Image

    Energy Technology Data Exchange (ETDEWEB)

    Ma, C; Yin, Y [Shandong Tumor Hospital, Jinan, Shandong Provice (China)

    2015-06-15

    Purpose: The purpose of this work was to determine the dosimetric benefit to normal tissues by tracking liver tumor dose in four dimensional radiation therapy (4DRT) on ten phases of four dimensional computer tomagraphy(4DCT) images. Methods: Target tracking each phase with the beam aperture for ten liver cancer patients were converted to cumulative plan and compared to the 3D plan with a merged target volume based on 4DCT image in radiation treatment planning system (TPS). The change in normal tissue dose was evaluated in the plan by using the parameters V5, V10, V15, V20,V25, V30, V35 and V40 (volumes receiving 5, 10, 15, 20, 25, 30, 35 and 40Gy, respectively) in the dose-volume histogram for the liver; mean dose for the following structures: liver, left kidney and right kidney; and maximum dose for the following structures: bowel, duodenum, esophagus, stomach and heart. Results: There was significant difference between 4D PTV(average 115.71cm3 )and ITV(169.86 cm3). When the planning objective is 95% volume of PTV covered by the prescription dose, the mean dose for the liver, left kidney and right kidney have an average decrease 23.13%, 49.51%, and 54.38%, respectively. The maximum dose for bowel, duodenum,esophagus, stomach and heart have an average decrease 16.77%, 28.07%, 24.28%, 4.89%, and 4.45%, respectively. Compared to 3D RT, radiation volume for the liver V5, V10, V15, V20, V25, V30, V35 and V40 by using the 4D plans have a significant decrease(P≤0.05). Conclusion: The 4D plan method creates plans that permit better sparing of the normal structures than the commonly used ITV method, which delivers the same dosimetric effects to the target.

  20. Dosimetric study of optimal beam number and arrangement for treatment of nasopharyngeal carcinoma with intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Budrukkar, Ashwini; Corry, June; Peters, Lester J.; Hope, Geoff; Cramb, Jim

    2004-01-01

    The purpose of this dosimetric study was to evaluate the effect of beam number and arrangement on the dose distribution with intensity-modulated radiation therapy in patients with nasopharyngeal cancer. Computed tomography data sets of seven patients who were treated for nasopharyngeal carcinoma at the Peter MacCallum Cancer Centre were used for the present dosimetric study. The dose planned was 70 Gy in 7 weeks for the gross nasopharyngeal and nodal disease and the biological equivalents of 60 Gy in 6 weeks for the high-risk and 50 Gy in 5 weeks for the low-risk nodal disease. A plan using seven fields was compared to that using nine fields in all patients. Plans were assessed on the dose to the planning target volume (PTV) and the degree of parotid sparing achieved by evaluating both dose-volume histograms (DVH) and axial slices. Seven fields (three anterior and four posterior) provide good PTV coverage and satisfactory parotid sparing in patients with localized nasopharyngeal lesions. Nine fields appear to be better for tumours with significant posterolateral parapharyngeal extension. Parotid sparing is consistently better with nine fields. Both DVH and axial slices need to be evaluated before accepting any plan Copyright (2004) Blackwell Publishing Asia Pty Ltd

  1. A dosimetric comparison between traditionally planned and inverse planned radiation therapy of non-small cell lung cancer

    International Nuclear Information System (INIS)

    Wu, V.W.C.; Sham, J.S.T.; Kwong, D.L.W.

    2003-01-01

    This study applied inverse planning in 3-dimensional conformal radiation therapy (3DCRT) of non-small cell lung cancer (NSCLC) patients and evaluated its dosimetric results by comparison with the forward planning of 3DCRT and inverse planning of intensity modulated radiotherapy (IMRT). For each of the 15 NSCLC patients recruited, the forward 3DCRT, inverse 3DCRT and inverse EVIRT plans were produced using the FOCUS treatment planning system. The dosimetric results and the planner's time of all treatment plans were recorded and compared. The inverse 3DCRT plans demonstrated the best target dose homogeneity among the three planning methods. The tumour control probability of the inverse 3DCRT plans was similar to the forward plans (p 0.217) but inferior to the IMRT plans (p < 0.001). A similar pattern was observed in uncomplicated tumour control. The average planning time for the inverse 3DCRT plans was the shortest and its difference was significant compared with the forward 3DCRT plans (p < 0.001) but not with the IMRT plans (p = 0.276). In conclusion, inverse planning for 3DCRT is a reasonable alternative to the forward planning for NSCLC patients with a reduction of the planner's time. However, further dose escalation and improvement of tumour control have to rely on IMRT. Copyright (2003) Australian Institute of Radiography

  2. Dosimetric Analysis of Radiation-induced Gastric Bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Mary, E-mail: maryfeng@umich.edu [Department of Radiation Oncology, University of Michigan School of Medicine, Ann Arbor, Michigan (United States); Normolle, Daniel [Department of Biostatistics, University of Pittsburgh, Pittsburgh, Pennsylvania (United States); Pan, Charlie C. [Department of Radiation Oncology, University of Michigan School of Medicine, Ann Arbor, Michigan (United States); Dawson, Laura A. [Department of Radiation Oncology, Princess Margaret Hospital, University of Toronto, Toronto, Ontario (Canada); Amarnath, Sudha [Department of Radiation Oncology, University of Michigan School of Medicine, Ann Arbor, Michigan (United States); Ensminger, William D. [Department of Internal Medicine, Division of Hematology Oncology, University of Michigan School of Medicine, Ann Arbor, Michigan (United States); Lawrence, Theodore S.; Ten Haken, Randall K. [Department of Radiation Oncology, University of Michigan School of Medicine, Ann Arbor, Michigan (United States)

    2012-09-01

    Purpose: Radiation-induced gastric bleeding has been poorly understood. In this study, we described dosimetric predictors for gastric bleeding after fractionated radiation therapy. Methods and Materials: The records of 139 sequential patients treated with 3-dimensional conformal radiation therapy (3D-CRT) for intrahepatic malignancies were reviewed. Median follow-up was 7.4 months. The parameters of a Lyman normal tissue complication probability (NTCP) model for the occurrence of {>=}grade 3 gastric bleed, adjusted for cirrhosis, were fitted to the data. The principle of maximum likelihood was used to estimate parameters for NTCP models. Results: Sixteen of 116 evaluable patients (14%) developed gastric bleeds at a median time of 4.0 months (mean, 6.5 months; range, 2.1-28.3 months) following completion of RT. The median and mean maximum doses to the stomach were 61 and 63 Gy (range, 46-86 Gy), respectively, after biocorrection of each part of the 3D dose distributions to equivalent 2-Gy daily fractions. The Lyman NTCP model with parameters adjusted for cirrhosis predicted gastric bleed. Best-fit Lyman NTCP model parameters were n=0.10 and m=0.21 and with TD{sub 50} (normal) = 56 Gy and TD{sub 50} (cirrhosis) = 22 Gy. The low n value is consistent with the importance of maximum dose; a lower TD{sub 50} value for the cirrhosis patients points out their greater sensitivity. Conclusions: This study demonstrates that the Lyman NTCP model has utility for predicting gastric bleeding and that the presence of cirrhosis greatly increases this risk. These findings should facilitate the design of future clinical trials involving high-dose upper abdominal radiation.

  3. Dosimetric Analysis of Radiation-induced Gastric Bleeding

    International Nuclear Information System (INIS)

    Feng, Mary; Normolle, Daniel; Pan, Charlie C.; Dawson, Laura A.; Amarnath, Sudha; Ensminger, William D.; Lawrence, Theodore S.; Ten Haken, Randall K.

    2012-01-01

    Purpose: Radiation-induced gastric bleeding has been poorly understood. In this study, we described dosimetric predictors for gastric bleeding after fractionated radiation therapy. Methods and Materials: The records of 139 sequential patients treated with 3-dimensional conformal radiation therapy (3D-CRT) for intrahepatic malignancies were reviewed. Median follow-up was 7.4 months. The parameters of a Lyman normal tissue complication probability (NTCP) model for the occurrence of ≥grade 3 gastric bleed, adjusted for cirrhosis, were fitted to the data. The principle of maximum likelihood was used to estimate parameters for NTCP models. Results: Sixteen of 116 evaluable patients (14%) developed gastric bleeds at a median time of 4.0 months (mean, 6.5 months; range, 2.1-28.3 months) following completion of RT. The median and mean maximum doses to the stomach were 61 and 63 Gy (range, 46-86 Gy), respectively, after biocorrection of each part of the 3D dose distributions to equivalent 2-Gy daily fractions. The Lyman NTCP model with parameters adjusted for cirrhosis predicted gastric bleed. Best-fit Lyman NTCP model parameters were n=0.10 and m=0.21 and with TD 50 (normal) = 56 Gy and TD 50 (cirrhosis) = 22 Gy. The low n value is consistent with the importance of maximum dose; a lower TD 50 value for the cirrhosis patients points out their greater sensitivity. Conclusions: This study demonstrates that the Lyman NTCP model has utility for predicting gastric bleeding and that the presence of cirrhosis greatly increases this risk. These findings should facilitate the design of future clinical trials involving high-dose upper abdominal radiation.

  4. Assessing the Dosimetric Accuracy of Magnetic Resonance-Generated Synthetic CT Images for Focal Brain VMAT Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Paradis, Eric, E-mail: eparadis@umich.edu [Department of Radiation Oncology, University of Michigan Hospital and Health Systems, Ann Arbor, Michigan (United States); Cao, Yue [Department of Radiation Oncology, University of Michigan Hospital and Health Systems, Ann Arbor, Michigan (United States); Department of Radiology, University of Michigan Hospital and Health Systems, Ann Arbor, Michigan (United States); Department of Biomedical Engineering, University of Michigan Hospital and Health Systems, Ann Arbor, Michigan (United States); Lawrence, Theodore S.; Tsien, Christina; Feng, Mary; Vineberg, Karen; Balter, James M. [Department of Radiation Oncology, University of Michigan Hospital and Health Systems, Ann Arbor, Michigan (United States)

    2015-12-01

    Purpose: The purpose of this study was to assess the dosimetric accuracy of synthetic CT (MRCT) volumes generated from magnetic resonance imaging (MRI) data for focal brain radiation therapy. Methods and Materials: A study was conducted in 12 patients with gliomas who underwent both MR and CT imaging as part of their simulation for external beam treatment planning. MRCT volumes were generated from MR images. Patients' clinical treatment planning directives were used to create 12 individual volumetric modulated arc therapy (VMAT) plans, which were then optimized 10 times on each of their respective CT and MRCT-derived electron density maps. Dose metrics derived from optimization criteria, as well as monitor units and gamma analyses, were evaluated to quantify differences between the imaging modalities. Results: Mean differences between planning target volume (PTV) doses on MRCT and CT plans across all patients were 0.0% (range: −0.1 to 0.2%) for D{sub 95%}; 0.0% (−0.7 to 0.6%) for D{sub 5%}; and −0.2% (−1.0 to 0.2%) for D{sub max}. MRCT plans showed no significant changes in monitor units (−0.4%) compared to CT plans. Organs at risk (OARs) had average D{sub max} differences of 0.0 Gy (−2.2 to 1.9 Gy) over 85 structures across all 12 patients, with no significant differences when calculated doses approached planning constraints. Conclusions: Focal brain VMAT plans optimized on MRCT images show excellent dosimetric agreement with standard CT-optimized plans. PTVs show equivalent coverage, and OARs do not show any overdose. These results indicate that MRI-derived synthetic CT volumes can be used to support treatment planning of most patients treated for intracranial lesions.

  5. Dosimetric impact of image-guided 3D conformal radiation therapy of prostate cancer

    International Nuclear Information System (INIS)

    Schaly, B; Song, W; Bauman, G S; Battista, J J; Van Dyk, J

    2005-01-01

    The goal of this work is to quantify the impact of image-guided conformal radiation therapy (CRT) on the dose distribution by correcting patient setup uncertainty and inter-fraction tumour motion. This was a retrospective analysis that used five randomly selected prostate cancer patients that underwent approximately 15 computed tomography (CT) scans during their radiation treatment course. The beam arrangement from the treatment plan was imported into each repeat CT study and the dose distribution was recalculated for the new beam setups. Various setup scenarios were then compared to assess the impact of image guidance on radiation treatment precision. These included (1) daily alignment to skin markers, thus representing a conventional beam setup without image guidance (2) alignment to bony anatomy for correction of daily patient setup error, thus representing on-line portal image guidance, and (3) alignment to the 'CTV of the day' for correction of inter-fraction tumour motion, thus representing on-line CT or ultrasound image guidance. Treatment scenarios (1) and (3) were repeated with a reduced CTV to PTV margin, where the former represents a treatment using small margins without daily image guidance. Daily realignment of the treatment beams to the prostate showed an average increase in minimum tumour dose of 1.5 Gy, in all cases where tumour 'geographic miss' without image guidance was apparent. However, normal tissue sparing did not improve unless the PTV margin was reduced. Daily realignment to the tumour combined with reducing the margin size by a factor of 2 resulted in an average escalation in tumour dose of 9.0 Gy for all five static plans. However, the prescription dose could be escalated by 13.8 Gy when accounting for changes in anatomy by accumulating daily doses using nonlinear image registration techniques. These results provide quantitative information on the effectiveness of image-guided radiation treatment of prostate cancer and demonstrate that

  6. CaSO4: Dy + Teflon dosimetric pellets for X, beta and gamma radiation detection

    International Nuclear Information System (INIS)

    Campos, L.L.; Lima, M.F.

    1987-08-01

    CaSO 4 : Dy + TEFLON dosimetric pellets with high sensitivity and low cost for X, beta and gamma radiation monitoring were studied and developed by the Dosimetric Material Production Laboratory of the Radiological Protection Departament and are disposable for sale. The thickness of the pellets are suitable for X, beta and gamma radiation measurements. The dosimetric properties of these pellets were determined and presented in this work. The results show the usefulness of 0,20mm thick pellets for beta radiation monitoring and 0,80mm thick pellets for x and gamma radiation detection. (Author) [pt

  7. Radiation process control, study and acceptance of dosimetric methods

    International Nuclear Information System (INIS)

    Radak, B.B.

    1984-01-01

    The methods of primary dosimetric standardization and the calibration of dosimetric monitors suitable for radiation process control were outlined in the form of a logical pattern in which they are in current use on industrial scale in Yugoslavia. The reliability of the process control of industrial sterilization of medical supplies for the last four years was discussed. The preparatory works for the intermittent use of electron beams in cable industry were described. (author)

  8. SU-E-J-169: The Dosimetric and Temporal Effects of Respiratory-Gated Radiation Therapy in Lung Cancer Patients

    International Nuclear Information System (INIS)

    Rouabhi, O; Gross, B; Xia, J; Bayouth, J

    2015-01-01

    Purpose: To evaluate the dosimetric and temporal effects of high dose rate treatment mode for respiratory-gated radiation therapy in lung cancer patients. Methods: Treatment plans from five lung cancer patients (3 nongated (Group 1), 2 gated at 80EX-80IN (Group 2)) were retrospectively evaluated. The maximum tumor motions range from 6–12 mm. Using the same planning criteria, four new treatment plans, corresponding to four gating windows (20EX–20IN, 40EX–40IN, 60EX–60IN, and 80EX–80IN), were generated for each patient. Mean tumor dose (MTD), mean lung dose (MLD), and lung V20 were used to assess the dosimetric effects. A MATLAB algorithm was developed to compute treatment time by considering gantry rotation time, time to position collimator leaves, dose delivery time (scaled relative to the gating window), and communication overhead. Treatment delivery time for each plan was estimated using a 500 MU/min dose rate for the original plans and a 1500 MU/min dose rate for the gated plans. Results: Differences in MTD were less than 1Gy across plans for all five patients. MLD and lung V20 were on average reduced between −16.1% to −6.0% and −20.0% to −7.2%, respectively for non-gated plans when compared with the corresponding gated plans, and between − 5.8% to −4.2% and −7.0% to −5.4%, respectively for plans originally gated at 80EX–80IN when compared with the corresponding 20EX-20IN to 60EX– 60IN gated plans. Treatment delivery times of gated plans using high dose rate were reduced on average between −19.7% (−1.9min) to −27.2% (−2.7min) for originally non-gated plans and −15.6% (−0.9min) to −20.3% (−1.2min) for originally 80EX-80IN gated plans. Conclusion: Respiratory-gated radiation therapy in lung cancer patients can reduce lung toxicity, while maintaining tumor dose. Using a gated high-dose-rate treatment, delivery time comparable to non-gated normal-dose-rate treatment can be achieved. This research is supported by Siemens

  9. Dosimetric comparison between helical tomotherapy and intensity-modulated radiation therapy plans for non-small cell lung cancer.

    Science.gov (United States)

    Meng, Ling-Ling; Feng, Lin-Chun; Wang, Yun-Lai; Dai, Xiang-Kun; Xie, Chuan-Bin

    2011-06-01

    Helical tomotherapy (HT) is a new image-guided intensity-modulated radiation therapy (IMRT) technique. It is reported that HT plan for non-small-cell lung cancer (NSCLC) can give better dose uniformity, dose gradients, and protection for the lung than IMRT plan. We compared the dosimetric characteristics of HT for NSCLC with those of conventional IMRT to observe the superiority of HT. There was a comparative case series comprising 10 patients with NSCLC. Computed tomographic (CT) images of delineated targets were transferred to the PrecisePlan planning system (IMRT) and Tomo planning system (HT). The prescription doses were 70 Gy/33F for the gross tumor volume (GTV) and the visible lymph nodes (GTVnd), and 60 Gy/33F for the clinical target volume (CTV) and the clinical target volume of the visible lymph nodes (CTVnd). The dose restrictions for organs at risk were as follows: the maximum dose to spinal cord ≤ 45 Gy, V20 to the total lungs 0.05). The maximum doses to the spinal cord, heart, esophagus and trachea in the HT plan were lower than those in the IMRT plan, but the differences were not statistically significant. The HT plan provids better dose uniformity, dose gradients, and protection for the organs at risk. It can reduce the high-dose radiation volume for lung and the MLD, but may deliver a larger lung volume of low-dose radiation.

  10. Impact of Multileaf Collimator Configuration Parameters on the Dosimetric Accuracy of 6-MV Intensity-Modulated Radiation Therapy Treatment Plans.

    Science.gov (United States)

    Petersen, Nick; Perrin, David; Newhauser, Wayne; Zhang, Rui

    2017-01-01

    The purpose of this study was to evaluate the impact of selected configuration parameters that govern multileaf collimator (MLC) transmission and rounded leaf offset in a commercial treatment planning system (TPS) (Pinnacle 3 , Philips Medical Systems, Andover, MA, USA) on the accuracy of intensity-modulated radiation therapy (IMRT) dose calculation. The MLC leaf transmission factor was modified based on measurements made with ionization chambers. The table of parameters containing rounded-leaf-end offset values was modified by measuring the radiation field edge as a function of leaf bank position with an ionization chamber in a scanning water-tank dosimetry system and comparing the locations to those predicted by the TPS. The modified parameter values were validated by performing IMRT quality assurance (QA) measurements on 19 gantry-static IMRT plans. Planar dose measurements were performed with radiographic film and a diode array (MapCHECK2) and compared to TPS calculated dose distributions using default and modified configuration parameters. Based on measurements, the leaf transmission factor was changed from a default value of 0.001 to 0.005. Surprisingly, this modification resulted in a small but statistically significant worsening of IMRT QA gamma-index passing rate, which revealed that the overall dosimetric accuracy of the TPS depends on multiple configuration parameters in a manner that is coupled and not intuitive because of the commissioning protocol used in our clinic. The rounded leaf offset table had little room for improvement, with the average difference between the default and modified offset values being -0.2 ± 0.7 mm. While our results depend on the current clinical protocols, treatment unit and TPS used, the methodology used in this study is generally applicable. Different clinics could potentially obtain different results and improve their dosimetric accuracy using our approach.

  11. Impact of multileaf collimator configuration parameters on the dosimetric accuracy of 6-MV Intensity-Modulated radiation therapy treatment plans

    Directory of Open Access Journals (Sweden)

    Nick Petersen

    2017-01-01

    Full Text Available The purpose of this study was to evaluate the impact of selected configuration parameters that govern multileaf collimator (MLC transmission and rounded leaf offset in a commercial treatment planning system (TPS (Pinnacle3, Philips Medical Systems, Andover, MA, USA on the accuracy of intensity-modulated radiation therapy (IMRT dose calculation. The MLC leaf transmission factor was modified based on measurements made with ionization chambers. The table of parameters containing rounded-leaf-end offset values was modified by measuring the radiation field edge as a function of leaf bank position with an ionization chamber in a scanning water-tank dosimetry system and comparing the locations to those predicted by the TPS. The modified parameter values were validated by performing IMRT quality assurance (QA measurements on 19 gantry-static IMRT plans. Planar dose measurements were performed with radiographic film and a diode array (MapCHECK2 and compared to TPS calculated dose distributions using default and modified configuration parameters. Based on measurements, the leaf transmission factor was changed from a default value of 0.001 to 0.005. Surprisingly, this modification resulted in a small but statistically significant worsening of IMRT QA gamma-index passing rate, which revealed that the overall dosimetric accuracy of the TPS depends on multiple configuration parameters in a manner that is coupled and not intuitive because of the commissioning protocol used in our clinic. The rounded leaf offset table had little room for improvement, with the average difference between the default and modified offset values being −0.2 ± 0.7 mm. While our results depend on the current clinical protocols, treatment unit and TPS used, the methodology used in this study is generally applicable. Different clinics could potentially obtain different results and improve their dosimetric accuracy using our approach.

  12. Dosimetric evaluation of whole-breast radiation therapy: Clinical experience

    International Nuclear Information System (INIS)

    Osei, Ernest; Darko, Johnson; Fleck, Andre; White, Jana; Kiciak, Alexander; Redekop, Rachel; Gopaul, Darin

    2015-01-01

    Radiation therapy of the intact breast is the standard therapy for preventing local recurrence of early-stage breast cancer following breast conservation surgery. To improve patient standard of care, there is a need to define a consistent and transparent treatment path for all patients that reduces significance variations in the acceptability of treatment plans. There is lack of consistency among institutions or individuals about what is considered an acceptable treatment plan: target coverage vis-à-vis dose to organs at risk (OAR). Clinical trials usually resolve these issues, as the criteria for an acceptable plan within the trial (target coverage and doses to OAR) are well defined. We developed an institutional criterion for accepting breast treatment plans in 2006 after analyzing treatment data of approximately 200 patients. The purpose of this article is to report on the dosimetric review of 623 patients treated in the last 18 months to evaluate the effectiveness of the previously developed plan acceptability criteria and any possible changes necessary to further improve patient care. The mean patient age is 61.6 years (range: 25.2 to 93.0 years). The mean breast separation for all the patients is 21.0 cm (range: 12.4 to 34.9 cm), and the mean planning target volume (PTV-eval) (breast volume for evaluation) is 884.0 cm"3 (range: 73.6 to 3684.6 cm"3). Overall, 314 (50.4%) patients had the disease in the left breast and 309 (49.6%) had it in the right breast. A total of 147 (23.6%) patients were treated using the deep inspiration breath-hold (DIBH) technique. The mean normalized PTV-eval receiving at least 92% (V_9_2_% _P_D) and 95% (V_9_5_% _P_D) of the prescribed dose (PD) are more than 99% and 97%, respectively, for all patients. The mean normalized PTV-eval receiving at least 105% (V_1_0_5_% _P_D) of the PD is less than 1% for all groups. The mean homogeneity index (HI), uniformity index (UI), and conformity index (CI) for the PTV-eval are 0.09 (range: 0

  13. Management and processing of dosimetric data of workers exposed to ionizing radiation

    International Nuclear Information System (INIS)

    Rasoarimalala, T.

    2012-01-01

    The Madagascar - INSTN Radiation protection and Dosimetry Department use the reader HARSHAW TLD 6600 for workers doses reading. Although the performance of this device, manual works is required to store and to maintain the dosimetric data after reading and to note the TLDs sent to the establishments. To avoid these manual works, this present work proposes computer programs written in Python and using SQLite software. One of the programs in python retrieves dose values after reading and transfers directly these doses in the workers database. The use of SQLite software provides a way for the dosimetric data management and the TLDs movement monitoring. The other program assesses estimation of the dose received by worker through a trend curve for workers dosimetric monitoring. The calculated differences of this curve over the curve connecting all points are less than 20%, acceptable limit in radiation protection for TLDs. This present work presents then significances for the personnel occupying individual monitoring of ionizing radiation workers and for these workers too. [fr

  14. Technical Note: Dosimetric effects of couch position variability on treatment plan quality with an MRI-guided Co-60 radiation therapy machine

    Energy Technology Data Exchange (ETDEWEB)

    Chow, Phillip E., E-mail: pechow@mednet.ucla.edu; Thomas, David H.; Agazaryan, Nzhde; Cao, Minsong; Low, Daniel A.; Yang, Yingli; Steinberg, Michael L.; Lee, Percy; Lamb, James M. [Department of Radiation Oncology, David Geffen School of Medicine at UCLA, Los Angeles, California 90095 (United States)

    2016-08-15

    Purpose: Magnetic resonance imaging (MRI) guidance in radiation therapy brings real-time imaging and adaptive planning into the treatment vault where it can account for interfraction and intrafraction movement of soft tissue. The only commercially available MRI-guided radiation therapy device is a three-head {sup 60}Co and MRI system with an integrated treatment planning system (TPS). Couch attenuation of the beam of up to 20% is well modeled in the TPS. Variations in the patient’s day-to-day position introduce discrepancies in the actual couch attenuation as modeled in the treatment plan. For this reason, the authors’ institution avoids plans with beams that pass through or near the couch edges. This study investigates the effects of differential beam attenuation by the couch due to couch shifts in order to determine whether couch edge avoidance restrictions can be lifted. Couch shifts were simulated using a Monte Carlo treatment planning system and ion chamber measurements performed for validation. Methods: A total of 27 plans from 23 patients were investigated. Couch shifts of 1 and 2 cm were introduced in combinations of lateral and vertical directions to simulate patient position variations giving 16 shifted plans per reference plan. The 1 and 2 cm shifts were based on shifts recorded in 320 treatment fractions. Results: Following TG176 recommendations for measurement methods, couch attenuation measurements agreed with TPS modeled attenuation to within 2.1%. Planning target volume D95 changed less than 1% for 1 and 2 cm couch shifts in only the x-direction and less than 3% for all directions. Conclusions: Dosimetry of all plans tested was robust to couch shifts up to ±2 cm. In general, couch shifts resulted in clinically insignificant dosimetric deviations. It is conceivable that in certain cases with large systematic couch shifts and plans that are particularly sensitive to shifts, dosimetric changes might rise to a clinically significant level.

  15. A Novel Simple Phantom for Verifying the Dose of Radiation Therapy

    Directory of Open Access Journals (Sweden)

    J. H. Lee

    2015-01-01

    Full Text Available A standard protocol of dosimetric measurements is used by the organizations responsible for verifying that the doses delivered in radiation-therapy institutions are within authorized limits. This study evaluated a self-designed simple auditing phantom for use in verifying the dose of radiation therapy; the phantom design, dose audit system, and clinical tests are described. Thermoluminescent dosimeters (TLDs were used as postal dosimeters, and mailable phantoms were produced for use in postal audits. Correction factors are important for converting TLD readout values from phantoms into the absorbed dose in water. The phantom scatter correction factor was used to quantify the difference in the scattered dose between a solid water phantom and homemade phantoms; its value ranged from 1.084 to 1.031. The energy-dependence correction factor was used to compare the TLD readout of the unit dose irradiated by audit beam energies with 60Co in the solid water phantom; its value was 0.99 to 1.01. The setup-condition factor was used to correct for differences in dose-output calibration conditions. Clinical tests of the device calibrating the dose output revealed that the dose deviation was within 3%. Therefore, our homemade phantoms and dosimetric system can be applied for accurately verifying the doses applied in radiation-therapy institutions.

  16. Proton therapy radiation pneumonitis local dose–response in esophagus cancer patients

    International Nuclear Information System (INIS)

    Echeverria, Alfredo E.; McCurdy, Matthew; Castillo, Richard; Bernard, Vincent; Ramos, Natalia Velez; Buckley, William; Castillo, Edward; Liu, Ping; Martinez, Josue; Guerrero, Thomas

    2013-01-01

    Purpose: This study quantifies pulmonary radiation toxicity in patients who received proton therapy for esophagus cancer. Materials/methods: We retrospectively studied 100 esophagus cancer patients treated with proton therapy. The linearity of the enhanced FDG uptake vs. proton dose was evaluated using the Akaike Information Criterion (AIC). Pneumonitis symptoms (RP) were assessed using the Common Toxicity Criteria for Adverse Events version 4.0 (CTCAEv4). The interaction of the imaging response with dosimetric parameters and symptoms was evaluated. Results: The RP scores were: 0 grade 4/5, 7 grade 3, 20 grade 2, 37 grade 1, and 36 grade 0. Each dosimetric parameter was significantly higher for the symptomatic group. The AIC winning models were 30 linear, 52 linear quadratic, and 18 linear logarithmic. There was no significant difference in the linear coefficient between models. The slope of the FDG vs. proton dose response was 0.022 for the symptomatic and 0.012 for the asymptomatic (p = 0.014). Combining dosimetric parameters with the slope did not improve the sensitivity or accuracy in identifying symptomatic cases. Conclusions: The proton radiation dose response on FDG PET/CT imaging exhibited a predominantly linear dose response on modeling. Symptomatic patients had a higher dose response slope

  17. Dosimetric evaluation of multi-pattern spatially fractionated radiation therapy using a multi-leaf collimator and collapsed cone convolution superposition dose calculation algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Stathakis, Sotirios [Department of Radiation Oncology, University of Texas Health Science Center San Antonio, 7979 Wurzbach Rd, San Antonio, TX 78229 (United States)], E-mail: stathakis@uthscsa.edu; Esquivel, Carlos; Gutierrez, Alonso N.; Shi, ChengYu; Papanikolaou, Niko [Department of Radiation Oncology, University of Texas Health Science Center San Antonio, 7979 Wurzbach Rd, San Antonio, TX 78229 (United States)

    2009-10-15

    Purpose: In this paper, we present an alternative to the originally proposed technique for the delivery of spatially fractionated radiation therapy (GRID) using multi-leaf collimator (MLC) shaped fields. We employ the MLC to deliver various pattern GRID treatments to large solid tumors and dosimetrically characterize the GRID fields. Methods and materials: The GRID fields were created with different open to blocked area ratios and with variable separation between the openings using a MLC. GRID designs were introduced into the Pinnacle{sup 3} treatment planning system, and the dose was calculated in a water phantom. Ionization chamber and film measurements using both Kodak EDR2 and Gafchromic EBT film were performed in a SolidWater phantom to determine the relative output of each GRID design as well as its spatial dosimetric characteristics. Results: Agreement within 5.0% was observed between the Pinnacle{sup 3} predicted dose distributions and the measurements for the majority of experiments performed. A higher magnitude of discrepancy (15%) was observed using a high photon beam energy (18 MV) and small GRID opening. Skin dose at the GRID openings was higher than the corresponding open field by a factor as high as three for both photon energies and was found to be independent of the open-to-blocked area ratio. Conclusion: In summary, we reaffirm that the MLC can be used to deliver spatially fractionated GRID therapy and show that various GRID patterns may be generated. The Pinnacle{sup 3} TPS can accurately calculate the dose of the different GRID patterns in our study to within 5% for the majority of the cases based on film and ion chamber measurements. Disadvantages of MLC-based GRID therapy are longer treatment times and higher surface doses.

  18. Radiation Therapy Deficiencies Identified During On-Site Dosimetry Visits by the Imaging and Radiation Oncology Core Houston Quality Assurance Center.

    Science.gov (United States)

    Kry, Stephen F; Dromgoole, Lainy; Alvarez, Paola; Leif, Jessica; Molineu, Andrea; Taylor, Paige; Followill, David S

    2017-12-01

    To review the dosimetric, mechanical, and programmatic deficiencies most frequently observed during on-site visits of radiation therapy facilities by the Imaging and Radiation Oncology Core Quality Assurance Center in Houston (IROC Houston). The findings of IROC Houston between 2000 and 2014, including 409 institutions and 1020 linear accelerators (linacs), were compiled. On-site evaluations by IROC Houston include verification of absolute calibration (tolerance of ±3%), relative dosimetric review (tolerances of ±2% between treatment planning system [TPS] calculation and measurement), mechanical evaluation (including multileaf collimator and kilovoltage-megavoltage isocenter evaluation against Task Group [TG]-142 tolerances), and general programmatic review (including institutional quality assurance program vs TG-40 and TG-142). An average of 3.1 deficiencies was identified at each institution visited, a number that has decreased slightly with time. The most common errors are tabulated and include TG-40/TG-142 compliance (82% of institutions were deficient), small field size output factors (59% of institutions had errors ≥3%), and wedge factors (33% of institutions had errors ≥3%). Dosimetric errors of ≥10%, including in beam calibration, were seen at many institutions. There is substantial room for improvement of both dosimetric and programmatic issues in radiation therapy, which should be a high priority for the medical physics community. Particularly relevant was suboptimal beam modeling in the TPS and a corresponding failure to detect these errors by not including TPS data in the linac quality assurance process. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Dosimetric Implications of an Injection of Hyaluronic Acid for Preserving the Rectal Wall in Prostate Stereotactic Body Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Chapet, Olivier, E-mail: olivier.chapet@chu-lyon.fr [Department of Radiation Oncology, Centre Hospitalier Lyon Sud, Pierre Benite (France); Udrescu, Corina [Department of Radiation Oncology, Centre Hospitalier Lyon Sud, Pierre Benite (France); Department of Medical Physics, Centre Hospitalier Lyon Sud, Pierre Benite (France); Tanguy, Ronan [Department of Radiation Oncology, Centre Hospitalier Lyon Sud, Pierre Benite (France); Ruffion, Alain [Department of Urology, Centre Hospitalier Lyon Sud, Pierre Benite (France); Fenoglietto, Pascal [Department of Radiation Oncology, Centre Val d' Aurelle, Montpellier (France); Sotton, Marie-Pierre [Department of Medical Physics, Centre Hospitalier Lyon Sud, Pierre Benite (France); Devonec, Marian [Department of Urology, Centre Hospitalier Lyon Sud, Pierre Benite (France); Colombel, Marc [Department of Urology, Hopital Edouard Herriot, Lyon (France); Jalade, Patrice [Department of Medical Physics, Centre Hospitalier Lyon Sud, Pierre Benite (France); Azria, David [Department of Radiation Oncology, Centre Val d' Aurelle, Montpellier (France)

    2014-02-01

    Purpose: This study assessed the contribution of ahyaluronic acid (HA) injection between the rectum and the prostate to reducing the dose to the rectal wall in stereotactic body radiation therapy (SBRT). Methods and Materials: As part of a phase 2 study of hypofractionated radiation therapy (62 Gy in 20 fractions), the patients received a transperineal injection of 10 cc HA between the rectum and the prostate. A dosimetric computed tomographic (CT) scan was systematically performed before (CT1) and after (CT2) the injection. Two 9-beam intensity modulated radiation therapy-SBRT plans were optimized for the first 10 patients on both CTs according to 2 dosage levels: 5 × 6.5 Gy (PlanA) and 5 × 8.5 Gy (PlanB). Rectal wall parameters were compared with a dose–volume histogram, and the prostate–rectum separation was measured at 7 levels of the prostate on the center line of the organ. Results: For both plans, the average volume of the rectal wall receiving the 90% isodose line (V90%) was reduced up to 90% after injection. There was no significant difference (P=.32) between doses received by the rectal wall on CT1 and CT2 at the base of the prostate. This variation became significant from the median plane to the apex of the prostate (P=.002). No significant differences were found between PlanA without HA and PlanB with HA for each level of the prostate (P=.77, at the isocenter of the prostate). Conclusions: HA injection significantly reduced the dose to the rectal wall and allowed a dose escalation from 6.5 Gy to 8.5 Gy without increasing the dose to the rectum. A phase 2 study is under way in our department to assess the rate of acute and late rectal toxicities when SBRT (5 × 8.5 Gy) is combined with an injection of HA.

  20. Dosimetric Implications of an Injection of Hyaluronic Acid for Preserving the Rectal Wall in Prostate Stereotactic Body Radiation Therapy

    International Nuclear Information System (INIS)

    Chapet, Olivier; Udrescu, Corina; Tanguy, Ronan; Ruffion, Alain; Fenoglietto, Pascal; Sotton, Marie-Pierre; Devonec, Marian; Colombel, Marc; Jalade, Patrice; Azria, David

    2014-01-01

    Purpose: This study assessed the contribution of ahyaluronic acid (HA) injection between the rectum and the prostate to reducing the dose to the rectal wall in stereotactic body radiation therapy (SBRT). Methods and Materials: As part of a phase 2 study of hypofractionated radiation therapy (62 Gy in 20 fractions), the patients received a transperineal injection of 10 cc HA between the rectum and the prostate. A dosimetric computed tomographic (CT) scan was systematically performed before (CT1) and after (CT2) the injection. Two 9-beam intensity modulated radiation therapy-SBRT plans were optimized for the first 10 patients on both CTs according to 2 dosage levels: 5 × 6.5 Gy (PlanA) and 5 × 8.5 Gy (PlanB). Rectal wall parameters were compared with a dose–volume histogram, and the prostate–rectum separation was measured at 7 levels of the prostate on the center line of the organ. Results: For both plans, the average volume of the rectal wall receiving the 90% isodose line (V90%) was reduced up to 90% after injection. There was no significant difference (P=.32) between doses received by the rectal wall on CT1 and CT2 at the base of the prostate. This variation became significant from the median plane to the apex of the prostate (P=.002). No significant differences were found between PlanA without HA and PlanB with HA for each level of the prostate (P=.77, at the isocenter of the prostate). Conclusions: HA injection significantly reduced the dose to the rectal wall and allowed a dose escalation from 6.5 Gy to 8.5 Gy without increasing the dose to the rectum. A phase 2 study is under way in our department to assess the rate of acute and late rectal toxicities when SBRT (5 × 8.5 Gy) is combined with an injection of HA

  1. Intensity Modulated Radiation Therapy for Early-Stage Primary Gastric Diffuse Large B-Cell Lymphoma: Dosimetric Analysis, Clinical Outcome, and Quality of Life

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xin; Fang, Hui; Tian, Yuan; Wang, Wei-Hu; Song, Yong-Wen; Wang, Shu-Lian; Liu, Yue-Ping [Department of Radiation Oncology, Cancer Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing (China); He, Xiao-Hui; Dong, Mei [Department of Medical Oncology, Cancer Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing (China); Ren, Hua; Jin, Jing [Department of Radiation Oncology, Cancer Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing (China); Li, Ye-Xiong, E-mail: yexiong@yahoo.com [Department of Radiation Oncology, Cancer Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing (China)

    2016-06-01

    Purpose: To evaluate the dosimetric superiority, efficacy, toxicity, and quality of life (QOL) data of intensity modulated radiation therapy (IMRT) in patients with primary gastric diffuse large B-cell lymphoma (PG-DLBCL). Methods and Materials: Forty-six consecutive patients with early-stage PG-DLBCL underwent IMRT after chemotherapy. The majority of patients (61.5%) were subclassified as the non-germinal center B cell–like subtype. Dosimetric parameters of the planning target volume (PTV) and organs at risk were assessed. Survival rates were depicted with the Kaplan-Meier method and compared with the log-rank test. Quality of life was evaluated using the QLQ-C30-STO22 questionnaires at the last follow-up contact. Results: The median PTV mean dose was 41.6 Gy. Only 0.73% of the PTV received <95% of the prescribed dose, indicating excellent target coverage. The median kidney V20 and liver V30 were 14.1% and 16.1%, respectively. The 5-year overall survival (OS), progression-free survival, and locoregional control rates for all patients were 80.4%, 75.0%, and 93.2%, respectively. Stage, lactate dehydrogenase level, and immunophenotype were significant prognostic factors for OS, and only stage was a significant factor for locoregional control. Consolidation IMRT in patients with complete response after chemotherapy resulted in significantly better OS and progression-free survival than salvage IMRT in patients with non-complete response. Two of 8 patients who had chronic liver disease experienced grade 4 or grade 5 acute hepatic failure after 4 to 5 cycles of rituximab-based chemotherapy and IMRT (40 Gy). No other serious acute or late toxicity was observed. The long-term global and functional QOL scales were excellent, with negligible symptom scales. Conclusions: Intensity modulated radiation therapy yielded excellent target coverage and critical tissue sparing and achieved favorable outcomes with acceptable toxicity and good long-term QOL in early-stage PG-DLBCL.

  2. Intensity Modulated Radiation Therapy for Early-Stage Primary Gastric Diffuse Large B-Cell Lymphoma: Dosimetric Analysis, Clinical Outcome, and Quality of Life

    International Nuclear Information System (INIS)

    Liu, Xin; Fang, Hui; Tian, Yuan; Wang, Wei-Hu; Song, Yong-Wen; Wang, Shu-Lian; Liu, Yue-Ping; He, Xiao-Hui; Dong, Mei; Ren, Hua; Jin, Jing; Li, Ye-Xiong

    2016-01-01

    Purpose: To evaluate the dosimetric superiority, efficacy, toxicity, and quality of life (QOL) data of intensity modulated radiation therapy (IMRT) in patients with primary gastric diffuse large B-cell lymphoma (PG-DLBCL). Methods and Materials: Forty-six consecutive patients with early-stage PG-DLBCL underwent IMRT after chemotherapy. The majority of patients (61.5%) were subclassified as the non-germinal center B cell–like subtype. Dosimetric parameters of the planning target volume (PTV) and organs at risk were assessed. Survival rates were depicted with the Kaplan-Meier method and compared with the log-rank test. Quality of life was evaluated using the QLQ-C30-STO22 questionnaires at the last follow-up contact. Results: The median PTV mean dose was 41.6 Gy. Only 0.73% of the PTV received <95% of the prescribed dose, indicating excellent target coverage. The median kidney V20 and liver V30 were 14.1% and 16.1%, respectively. The 5-year overall survival (OS), progression-free survival, and locoregional control rates for all patients were 80.4%, 75.0%, and 93.2%, respectively. Stage, lactate dehydrogenase level, and immunophenotype were significant prognostic factors for OS, and only stage was a significant factor for locoregional control. Consolidation IMRT in patients with complete response after chemotherapy resulted in significantly better OS and progression-free survival than salvage IMRT in patients with non-complete response. Two of 8 patients who had chronic liver disease experienced grade 4 or grade 5 acute hepatic failure after 4 to 5 cycles of rituximab-based chemotherapy and IMRT (40 Gy). No other serious acute or late toxicity was observed. The long-term global and functional QOL scales were excellent, with negligible symptom scales. Conclusions: Intensity modulated radiation therapy yielded excellent target coverage and critical tissue sparing and achieved favorable outcomes with acceptable toxicity and good long-term QOL in early-stage PG-DLBCL.

  3. Correlation of osteoradionecrosis and dental events with dosimetric parameters in intensity-modulated radiation therapy for head-and-neck cancer.

    Science.gov (United States)

    Gomez, Daniel R; Estilo, Cherry L; Wolden, Suzanne L; Zelefsky, Michael J; Kraus, Dennis H; Wong, Richard J; Shaha, Ashok R; Shah, Jatin P; Mechalakos, James G; Lee, Nancy Y

    2011-11-15

    Osteoradionecrosis (ORN) is a known complication of radiation therapy to the head and neck. However, the incidence of this complication with intensity-modulated radiation therapy (IMRT) and dental sequelae with this technique have not been fully elucidated. From December 2000 to July 2007, 168 patients from our institution have been previously reported for IMRT of the oral cavity, nasopharynx, larynx/hypopharynx, sinus, and oropharynx. All patients underwent pretreatment dental evaluation, including panoramic radiographs, an aggressive fluoride regimen, and a mouthguard when indicated. The median maximum mandibular dose was 6,798 cGy, and the median mean mandibular dose was 3,845 cGy. Patient visits were retrospectively reviewed for the incidence of ORN, and dental records were reviewed for the development of dental events. Univariate analysis was then used to assess the effect of mandibular and parotid gland dosimetric parameters on dental endpoints. With a median clinic follow-up of 37.4 months (range, 0.8-89.6 months), 2 patients, both with oral cavity primaries, experienced ORN. Neither patient had preradiation dental extractions. The maximum mandibular dose and mean mandibular dose of the 2 patients were 7,183 and 6,828 cGy and 5812 and 5335 cGy, respectively. In all, 17% of the patients (n = 29) experienced a dental event. A mean parotid dose of >26 Gy was predictive of a subsequent dental caries, whereas a maximum mandibular dose >70 Gy and a mean mandibular dose >40 Gy were correlated with dental extractions after IMRT. ORN is rare after head-and-neck IMRT, but is more common with oral cavity primaries. Our results suggest different mechanisms for radiation-induced caries versus extractions. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. Correlation of Osteoradionecrosis and Dental Events With Dosimetric Parameters in Intensity-Modulated Radiation Therapy for Head-and-Neck Cancer

    International Nuclear Information System (INIS)

    Gomez, Daniel R.; Estilo, Cherry L.; Wolden, Suzanne L.; Zelefsky, Michael J.; Kraus, Dennis H.; Wong, Richard J.; Shaha, Ashok R.; Shah, Jatin P.; Mechalakos, James G.; Lee, Nancy Y.

    2011-01-01

    Purpose: Osteoradionecrosis (ORN) is a known complication of radiation therapy to the head and neck. However, the incidence of this complication with intensity-modulated radiation therapy (IMRT) and dental sequelae with this technique have not been fully elucidated. Methods and Materials: From December 2000 to July 2007, 168 patients from our institution have been previously reported for IMRT of the oral cavity, nasopharynx, larynx/hypopharynx, sinus, and oropharynx. All patients underwent pretreatment dental evaluation, including panoramic radiographs, an aggressive fluoride regimen, and a mouthguard when indicated. The median maximum mandibular dose was 6,798 cGy, and the median mean mandibular dose was 3,845 cGy. Patient visits were retrospectively reviewed for the incidence of ORN, and dental records were reviewed for the development of dental events. Univariate analysis was then used to assess the effect of mandibular and parotid gland dosimetric parameters on dental endpoints. Results: With a median clinic follow-up of 37.4 months (range, 0.8–89.6 months), 2 patients, both with oral cavity primaries, experienced ORN. Neither patient had preradiation dental extractions. The maximum mandibular dose and mean mandibular dose of the 2 patients were 7,183 and 6,828 cGy and 5812 and 5335 cGy, respectively. In all, 17% of the patients (n = 29) experienced a dental event. A mean parotid dose of >26 Gy was predictive of a subsequent dental caries, whereas a maximum mandibular dose >70 Gy and a mean mandibular dose >40 Gy were correlated with dental extractions after IMRT. Conclusions: ORN is rare after head-and-neck IMRT, but is more common with oral cavity primaries. Our results suggest different mechanisms for radiation-induced caries versus extractions.

  5. Correlation of Osteoradionecrosis and Dental Events With Dosimetric Parameters in Intensity-Modulated Radiation Therapy for Head-and-Neck Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, Daniel R., E-mail: dgomez@mdanderson.org [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Estilo, Cherry L. [Dental Service, Department of Surgery, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Wolden, Suzanne L.; Zelefsky, Michael J. [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Kraus, Dennis H.; Wong, Richard J.; Shaha, Ashok R.; Shah, Jatin P. [Department of Head and Neck Surgery, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Mechalakos, James G.; Lee, Nancy Y. [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States)

    2011-11-15

    Purpose: Osteoradionecrosis (ORN) is a known complication of radiation therapy to the head and neck. However, the incidence of this complication with intensity-modulated radiation therapy (IMRT) and dental sequelae with this technique have not been fully elucidated. Methods and Materials: From December 2000 to July 2007, 168 patients from our institution have been previously reported for IMRT of the oral cavity, nasopharynx, larynx/hypopharynx, sinus, and oropharynx. All patients underwent pretreatment dental evaluation, including panoramic radiographs, an aggressive fluoride regimen, and a mouthguard when indicated. The median maximum mandibular dose was 6,798 cGy, and the median mean mandibular dose was 3,845 cGy. Patient visits were retrospectively reviewed for the incidence of ORN, and dental records were reviewed for the development of dental events. Univariate analysis was then used to assess the effect of mandibular and parotid gland dosimetric parameters on dental endpoints. Results: With a median clinic follow-up of 37.4 months (range, 0.8-89.6 months), 2 patients, both with oral cavity primaries, experienced ORN. Neither patient had preradiation dental extractions. The maximum mandibular dose and mean mandibular dose of the 2 patients were 7,183 and 6,828 cGy and 5812 and 5335 cGy, respectively. In all, 17% of the patients (n = 29) experienced a dental event. A mean parotid dose of >26 Gy was predictive of a subsequent dental caries, whereas a maximum mandibular dose >70 Gy and a mean mandibular dose >40 Gy were correlated with dental extractions after IMRT. Conclusions: ORN is rare after head-and-neck IMRT, but is more common with oral cavity primaries. Our results suggest different mechanisms for radiation-induced caries versus extractions.

  6. Dosimetric evaluation of 4 different treatment modalities for curative-intent stereotactic body radiation therapy for isolated thoracic spinal metastases

    International Nuclear Information System (INIS)

    Yang, Jun; Ma, Lin; Wang, Xiao-Shen; Xu, Wei Xu; Cong, Xiao-Hu; Xu, Shou-Ping; Ju, Zhong-Jian; Du, Lei; Cai, Bo-Ning; Yang, Jack

    2016-01-01

    To investigate the dosimetric characteristics of 4 SBRT-capable dose delivery systems, CyberKnife (CK), Helical TomoTherapy (HT), Volumetric Modulated Arc Therapy (VMAT) by Varian RapidArc (RA), and segmental step-and-shoot intensity-modulated radiation therapy (IMRT) by Elekta, on isolated thoracic spinal lesions. CK, HT, RA, and IMRT planning were performed simultaneously for 10 randomly selected patients with 6 body types and 6 body + pedicle types with isolated thoracic lesions. The prescription was set with curative intent and dose of either 33 Gy in 3 fractions (3F) or 40 Gy in 5F to cover at least 90% of the planning target volume (PTV), correspondingly. Different dosimetric indices, beam-on time, and monitor units (MUs) were evaluated to compare the advantages/disadvantages of each delivery modality. In ensuring the dose-volume constraints for cord and esophagus of the premise, CK, HT, and RA all achieved a sharp conformity index (CI) and a small penumbra volume compared to IMRT. RA achieved a CI comparable to those from CK, HT, and IMRT. CK had a heterogeneous dose distribution in the target as its radiosurgical nature with less dose uniformity inside the target. CK had the longest beam-on time and the largest MUs, followed by HT and RA. IMRT presented the shortest beam-on time and the least MUs delivery. For the body-type lesions, CK, HT, and RA satisfied the target coverage criterion in 6 cases, but the criterion was satisfied in only 3 (50%) cases with the IMRT technique. For the body + pedicle-type lesions, HT satisfied the criterion of the target coverage of ≥90% in 4 of the 6 cases, and reached a target coverage of 89.0% in another case. However, the criterion of the target coverage of ≥90% was reached in 2 cases by CK and RA, and only in 1 case by IMRT. For curative-intent SBRT of isolated thoracic spinal lesions, RA is the first choice for the body-type lesions owing to its delivery efficiency (time); the second choice is CK or HT; HT is the

  7. Dosimetric evaluation of 4 different treatment modalities for curative-intent stereotactic body radiation therapy for isolated thoracic spinal metastases

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Jun [Department of Radiation Oncology, Chinese PLA General Hospital, 28 Fuxing Road, Beijing, 100853 (China); Department of Oncology, First Affiliated Hospital of Xinxiang Medical University, 88 Jiankang Road, Weihui, Henan, 453100 (China); Ma, Lin [Department of Radiation Oncology, Chinese PLA General Hospital, 28 Fuxing Road, Beijing, 100853 (China); Department of Radiation Oncology, Hainan Branch of Chinese PLA General Hospital, Haitang Bay, Sanya, 572000 (China); Wang, Xiao-Shen; Xu, Wei Xu; Cong, Xiao-Hu; Xu, Shou-Ping; Ju, Zhong-Jian [Department of Radiation Oncology, Chinese PLA General Hospital, 28 Fuxing Road, Beijing, 100853 (China); Du, Lei [Department of Radiation Oncology, Hainan Branch of Chinese PLA General Hospital, Haitang Bay, Sanya, 572000 (China); Cai, Bo-Ning [Department of Radiation Oncology, Chinese PLA General Hospital, 28 Fuxing Road, Beijing, 100853 (China); Yang, Jack [Department of Radiation Oncology, Monmouth Medical Center, 300 2nd Avenue, Long Branch, NJ 07740 (United States)

    2016-07-01

    To investigate the dosimetric characteristics of 4 SBRT-capable dose delivery systems, CyberKnife (CK), Helical TomoTherapy (HT), Volumetric Modulated Arc Therapy (VMAT) by Varian RapidArc (RA), and segmental step-and-shoot intensity-modulated radiation therapy (IMRT) by Elekta, on isolated thoracic spinal lesions. CK, HT, RA, and IMRT planning were performed simultaneously for 10 randomly selected patients with 6 body types and 6 body + pedicle types with isolated thoracic lesions. The prescription was set with curative intent and dose of either 33 Gy in 3 fractions (3F) or 40 Gy in 5F to cover at least 90% of the planning target volume (PTV), correspondingly. Different dosimetric indices, beam-on time, and monitor units (MUs) were evaluated to compare the advantages/disadvantages of each delivery modality. In ensuring the dose-volume constraints for cord and esophagus of the premise, CK, HT, and RA all achieved a sharp conformity index (CI) and a small penumbra volume compared to IMRT. RA achieved a CI comparable to those from CK, HT, and IMRT. CK had a heterogeneous dose distribution in the target as its radiosurgical nature with less dose uniformity inside the target. CK had the longest beam-on time and the largest MUs, followed by HT and RA. IMRT presented the shortest beam-on time and the least MUs delivery. For the body-type lesions, CK, HT, and RA satisfied the target coverage criterion in 6 cases, but the criterion was satisfied in only 3 (50%) cases with the IMRT technique. For the body + pedicle-type lesions, HT satisfied the criterion of the target coverage of ≥90% in 4 of the 6 cases, and reached a target coverage of 89.0% in another case. However, the criterion of the target coverage of ≥90% was reached in 2 cases by CK and RA, and only in 1 case by IMRT. For curative-intent SBRT of isolated thoracic spinal lesions, RA is the first choice for the body-type lesions owing to its delivery efficiency (time); the second choice is CK or HT; HT is the

  8. Sparing of the hippocampus and limbic circuit during whole brain radiation therapy: a dosimetric study using helical tomotherapy

    International Nuclear Information System (INIS)

    Marsh, J.C.; Gielda, B.T.; Herskovic, A.M.; Turian, J.V.

    2010-01-01

    Full text: The study aims to assess the feasibility of dosimetrically sparing the limbic circuit during whole brain radiation therapy (WBRT) and prophylactic cranial irradiation (PCI). Methods and Materials: We contoured the brain/brainstem on fused MRI and CT as the target volume (PTV) in 11 patients, excluding the hippocampus and the rest of the limbic circuit, which were considered organs at risk (OARs). PCI and WBRT helical tomotherapy plans were prepared for each patient with a 1.0-cm field width, pitch 0.285, initial modulation factor = 2.5. We attempted to spare the hippocampus and the rest of the limbic circuit while treating the rest of the brain to 30 Gy in 15 fractions (PCI) or 35 Gy in 14 fractions (WBRT) with VlOO ∼ 95%. The quality of the plans was assessed by calculating mean dose and equivalent uniform dose (EUD) for OARs and the % volume of the PTV receiving the prescribed dose, V 100. Results: In the PCI plans, mean doses/EUD were: hippocampus 12.5 Gy/ 14.23 Gy, rest of limbic circuit 17.0 Gy/19.02 Gy. In the WBRT plans, mean doses/EUD were: hippocampus 14.3 Gy/16.07 Gy, rest of limbic circuit 17.9 Gy/20.74 Gy. The mean VlOO for the rest of the brain (PTV) were 94.7% (PCl) and 95.1 % (WBRT). Mean PCI and WBRT treatment times were essentially identical (mean 15.23 min, range 14.27-17.5). Conclusions: It is dosimetrically feasible to spare the hippocampus and the rest of the limbic circuit using helical tomotherapy while treating the rest of the brain to full dose.

  9. Weekly Volume and Dosimetric Changes During Chemoradiotherapy With Intensity-Modulated Radiation Therapy for Head and Neck Cancer: A Prospective Observational Study

    Energy Technology Data Exchange (ETDEWEB)

    Bhide, Shreerang A [Institute of Cancer Research, 237 Fulham Road, London SW6 6JB (United Kingdom); Head and Neck Unit, Royal Marsden NHS Foundation Trust Hospital, London SW3 6JJ (United Kingdom); Davies, Mark; Burke, Kevin; McNair, Helen A; Hansen, Vibeke [Department of Radiation Oncology, Royal Marsden NHS Foundation Trust Hospital, London and Sutton (United Kingdom); Barbachano, Y [Department of Statistics, Royal Marsden NHS Foundation Trust Hospital, London and Sutton (United Kingdom); El-Hariry, I A [Head and Neck Unit, Royal Marsden NHS Foundation Trust Hospital, London SW3 6JJ (United Kingdom); Newbold, Kate [Department of Radiation Oncology, Royal Marsden NHS Foundation Trust Hospital, London and Sutton (United Kingdom); Harrington, Kevin J [Institute of Cancer Research, 237 Fulham Road, London SW6 6JB (United Kingdom); Head and Neck Unit, Royal Marsden NHS Foundation Trust Hospital, London SW3 6JJ (United Kingdom); Nutting, Christopher M., E-mail: chris.nutting@rmh.nhs.u [Head and Neck Unit, Royal Marsden NHS Foundation Trust Hospital, London SW3 6JJ (United Kingdom)

    2010-04-15

    Purpose: The aim of this study was to investigate prospectively the weekly volume changes in the target volumes and organs at risk and the resulting dosimetric changes during induction chemotherapy followed by chemoradiotherapy with intensity-modulated radiation therapy (C-IMRT) for head-and-neck cancer patients. Methods and Materials: Patients receiving C-IMRT for head-and-neck cancer had repeat CT scans at weeks 2, 3, 4, and 5 during radiotherapy. The volume changes of clinical target volume 1 (CTV1) and CTV2 and the resulting dosimetric changes to planning target volume 1 (PTV1) and PTV2 and the organs at risk were measured. Results: The most significant volume differences were seen at week 2 for CTV1 and CTV2. The reductions in the volumes of CTV1 and CTV2 at week 2 were 3.2% and 10%, respectively (p = 0.003 and p < 0.001). The volume changes resulted in a significant reduction in the minimum dose to PTV1 and PTV2 (2 Gy, p = 0.002, and 3.9 Gy, p = 0.03, respectively) and an increased dose range across PTV1 and PTV2 (2.5 Gy, p < 0.001, and 5.1 Gy, p = 0.008, respectively). There was a 15% reduction in the parotid volumes by week 2 (p < 0.001) and 31% by week 4 (p < 0.001). There was a statistically significant increase in the mean dose to the ipsilateral parotid only at week 4 (2.7 Gy, p = 0.006). The parotid glands shifted medially by an average of 2.3 mm (p < 0.001) by week 4. Conclusion: The most significant volumetric changes and dosimetric alterations in the tumor volumes and organs at risk during a course of C-IMRT occur by week 2 of radiotherapy. Further adaptive radiotherapy with replanning, if appropriate, is recommended.

  10. Radiation therapy: dosimetry study of the effect of the composition of Pb alloys by PENELOPE

    Directory of Open Access Journals (Sweden)

    Jose McDonnell

    2011-02-01

    Full Text Available Radiotherapy is a widely used treatment for cancer. Currently applying the technique of Intensity Modulated Radiation Therapy, in which an important aspect is the modulation of the radiation beam to generate a non-uniform dose distribution in the tumor. One way to achieve the above non-uniform dose distribution is using solid compensators. In the market there are a number of materials used to manufacture compensators. Pb alloys on the market are: Cerromatrix, Rose, Wood, Newton, Darcet, whose compositions vary with respect to the composition of the lipowitz metal. This paper quantifies the dosimetric effects of the composition of commercial alloys, routinely used in radiotherapy. This quantification is important because of its impact on the total uncertainty of treatment accepted in the dosimetric calculations. To investigate the dosimetric effect of the composition of commercial alloys in the market we used the PENELOPE code, code that allows the simulation of radiation transport in different media by Monte Carlo method.The results show that there is a difference dosimetric respect lipowitz material, ranging from 7 % to 9 % for the materials investigated. These values indicate the importance of knowing exactly the dosimetric characteristics of the material used as compensator for their implications in the dose calculation.

  11. Dosimetric characterization of a 2-D array of 223 solid state detectors for daily morning checks in Tomo Therapy equipment

    International Nuclear Information System (INIS)

    Reyes S, U.; Sosa A, M.; Vega C, H. R.

    2015-10-01

    Tomo Therapy is a new technique for the cancer treatment; however, the equipment must meet nearly all mechanical and dosimetric characteristics of a conventional linear accelerator for medical use. Daily quality controls are vital to the good operation of the equipment and thus guarantee excellent quality in the daily delivery of treatments. This paper presents the procedure of the dosimetric characterization of a two-dimensional array of 223 solid state detectors, called TomoDose of the Sun Nuclear Company. Dosimetric important criteria are established to perform these checks quickly and accurately. Dosimetric tests proposed are: repeatability, linearity, dependence of Sad and SSD. Some results are compared with readings of the ionization chamber Exradim A1SL. Finally the results of 30 consecutive days are presented to establish criteria for evidence of dose, field size, symmetry and flattening of the radiation beam on Tomo Therapy equipment. Expected values for daily verification are: Dose constancy of 194.89 c Gy, σ= 1.31 c Gy, symmetry in the X axis of -0.19 %, σ=0.08 %, symmetry in the Y axis of 1.66 %, σ= 0.05 %, flattened in the X axis of 25.71 %, σ= 0.05 % and flattened in the Y axis of 6.41 %, σ= 10.23 %. Field sizes obtained were 40.45 cm in the X axis and 5.10 on the Y axis, with standard deviations of 0.02 cm and 0.01 cm, respectively. TomoDose dosimetric values, compared to the values obtained with ionization chamber, presented differences smaller than 2%. (Author)

  12. Dosimetric systems developed in Brazil for the radiation processes quality control

    International Nuclear Information System (INIS)

    Galante, Ana Maria Sisti; Campos, Leticia Lucente

    2011-01-01

    In order to apply new technologies to the industrial processing of materials aiming economy, efficiency, speed and high quality, ionizing radiation has been used in medicine, archaeology, chemistry, food preservation and other areas. For this reason, the dosimetry area looks for improve current dosimeters and develop new materials for application on quality control of these processes. In Brazil, the research in the dosimetry area occurs with great speed providing many different dosimetric systems. The chemical dosimetry is the most used technique in routine dosimetry, which requires fast and accurate responses. This technique involves determination of absorbed dose by measuring chemical changes radiation induced in the materials. Different dosimetric systems were developed at IPEN for application on radiation process quality and all of them present excellent results; the low cost of these materials allows a more effective dose control, therefore, a larger area or volume can be monitored. (author).

  13. Dosimetric evaluation of a novel polymer gel dosimeter for proton therapy

    Energy Technology Data Exchange (ETDEWEB)

    Zeidan, O. A.; Sriprisan, S. I.; Lopatiuk-Tirpak, O.; Kupelian, P. A.; Meeks, S. L.; Hsi, W. C.; Li, Z.; Palta, J. R.; Maryanski, M. J. [M. D. Anderson Cancer Center Orlando, Orlando, Florida 32806 (United States); University of Florida Proton Therapy Institute, Jacksonville, Florida 32206 (United States); MGS Research, Inc., Madison, Connecticut 06443 (United States)

    2010-05-15

    Purpose: The aim of this study is to evaluate the dosimetric performance of a newly developed proton-sensitive polymer gel formulation for proton therapy dosimetry. Methods: Using passive scattered modulated and nonmodulated proton beams, the dose response of the gel was assessed. A next-generation optical CT scanner is used as the readout mechanism of the radiation-induced absorbance in the gel medium. Comparison of relative dose profiles in the gel to ion chamber profiles in water is performed. A simple and easily reproducible calibration protocol is established for routine gel batch calibrations. Relative stopping power ratio measurement of the gel medium was performed to ensure accurate water-equivalent depth dose scaling. Measured dose distributions in the gel were compared to treatment planning system for benchmark irradiations and quality of agreement is assessed using clinically relevant gamma index criteria. Results: The dosimetric response of the gel was mapped up to 600 cGy using an electron-based calibration technique. Excellent dosimetric agreement is observed between ion chamber data and gel. The most notable result of this work is the fact that this gel has no observed dose quenching in the Bragg peak region. Quantitative dose distribution comparisons to treatment planning system calculations show that most (>97%) of the gel dose maps pass the 3%/3 mm gamma criterion. Conclusions: This study shows that the new proton-sensitive gel dosimeter is capable of reproducing ion chamber dose data for modulated and nonmodulated Bragg peak beams with different clinical beam energies. The findings suggest that the gel dosimeter can be used as QA tool for millimeter range verification of proton beam deliveries in the dosimeter medium.

  14. Dosimetric evaluation of a novel polymer gel dosimeter for proton therapy

    International Nuclear Information System (INIS)

    Zeidan, O. A.; Sriprisan, S. I.; Lopatiuk-Tirpak, O.; Kupelian, P. A.; Meeks, S. L.; Hsi, W. C.; Li, Z.; Palta, J. R.; Maryanski, M. J.

    2010-01-01

    Purpose: The aim of this study is to evaluate the dosimetric performance of a newly developed proton-sensitive polymer gel formulation for proton therapy dosimetry. Methods: Using passive scattered modulated and nonmodulated proton beams, the dose response of the gel was assessed. A next-generation optical CT scanner is used as the readout mechanism of the radiation-induced absorbance in the gel medium. Comparison of relative dose profiles in the gel to ion chamber profiles in water is performed. A simple and easily reproducible calibration protocol is established for routine gel batch calibrations. Relative stopping power ratio measurement of the gel medium was performed to ensure accurate water-equivalent depth dose scaling. Measured dose distributions in the gel were compared to treatment planning system for benchmark irradiations and quality of agreement is assessed using clinically relevant gamma index criteria. Results: The dosimetric response of the gel was mapped up to 600 cGy using an electron-based calibration technique. Excellent dosimetric agreement is observed between ion chamber data and gel. The most notable result of this work is the fact that this gel has no observed dose quenching in the Bragg peak region. Quantitative dose distribution comparisons to treatment planning system calculations show that most (>97%) of the gel dose maps pass the 3%/3 mm gamma criterion. Conclusions: This study shows that the new proton-sensitive gel dosimeter is capable of reproducing ion chamber dose data for modulated and nonmodulated Bragg peak beams with different clinical beam energies. The findings suggest that the gel dosimeter can be used as QA tool for millimeter range verification of proton beam deliveries in the dosimeter medium.

  15. Brachial Plexopathy in Apical Non-Small Cell Lung Cancer Treated With Definitive Radiation: Dosimetric Analysis and Clinical Implications

    International Nuclear Information System (INIS)

    Eblan, Michael J.; Corradetti, Michael N.; Lukens, J. Nicholas; Xanthopoulos, Eric; Mitra, Nandita; Christodouleas, John P.; Grover, Surbhi; Fernandes, Annemarie T.; Langer, Corey J.; Evans, Tracey L.; Stevenson, James; Rengan, Ramesh; Apisarnthanarax, Smith

    2013-01-01

    Purpose: Data are limited on the clinical significance of brachial plexopathy in patients with apical non-small cell lung cancers (NSCLC) treated with definitive radiation therapy. We report the rates of radiation-induced brachial plexopathy (RIBP) and tumor-related brachial plexopathy (TRBP) and associated dosimetric parameters in apical NSCLC patients. Methods and Materials: Charts of NSCLC patients with primary upper lobe or superiorly located nodal disease who received ≥50 Gy of definitive conventionally fractionated radiation or chemoradiation were retrospectively reviewed for evidence of brachial plexopathy and categorized as RIBP, TRBP, or trauma-related. Dosimetric data were gathered on ipsilateral brachial plexuses (IBP) contoured according to Radiation Therapy Oncology Group atlas guidelines. Results: Eighty patients were identified with a median follow-up and survival time of 17.2 and 17.7 months, respectively. The median prescribed dose was 66.6 Gy (range, 50.4-84.0), and 71% of patients received concurrent chemotherapy. RIBP occurred in 5 patients with an estimated 3-year rate of 12% when accounting for competing risk of death. Seven patients developed TRBP (estimated 3-year rate of 13%), comprising 24% of patients who developed locoregional failures. Grade 3 brachial plexopathy was more common in patients who experienced TRBP than RIBP (57% vs 20%). No patient who received ≤78 Gy to the IBP developed RIBP. On multivariable competing risk analysis, IBP V76 receiving ≥1 cc, and primary tumor failure had the highest hazard ratios for developing RIBP and TRBP, respectively. Conclusions: RIBP is a relatively uncommon complication in patients with apical NSCLC tumors receiving definitive doses of radiation, while patients who develop primary tumor failures are at high risk for developing morbid TRBP. These findings suggest that the importance of primary tumor control with adequate doses of radiation outweigh the risk of RIBP in this population of

  16. Clinical and Dosimetric Predictors of Acute Severe Lymphopenia During Radiation Therapy and Concurrent Temozolomide for High-Grade Glioma

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Jiayi, E-mail: jhuang@radonc.wustl.edu [Department of Radiation Oncology, Washington University School of Medicine, St Louis, Missouri (United States); DeWees, Todd A.; Badiyan, Shahed N.; Speirs, Christina K.; Mullen, Daniel F.; Fergus, Sandra [Department of Radiation Oncology, Washington University School of Medicine, St Louis, Missouri (United States); Tran, David D.; Linette, Gerry; Campian, Jian L. [Division of Medical Oncology, Department of Medicine, Washington University School of Medicine, St Louis, Missouri (United States); Chicoine, Michael R.; Kim, Albert H.; Dunn, Gavin [Department of Neurosurgery, Washington University School of Medicine, St Louis, Missouri (United States); Simpson, Joseph R.; Robinson, Clifford G. [Department of Radiation Oncology, Washington University School of Medicine, St Louis, Missouri (United States)

    2015-08-01

    Purpose: Acute severe lymphopenia (ASL) frequently develops during radiation therapy (RT) and concurrent temozolomide (TMZ) for high-grade glioma (HGG) and is associated with decreased survival. The current study was designed to identify potential predictors of ASL, with a focus on actionable RT-specific dosimetric parameters. Methods and Materials: From January 2007 to December 2012, 183 patients with HGG were treated with RT+TMZ and had available data including total lymphocyte count (TLC) and radiation dose-volume histogram parameters. ASL was defined as TLC of <500/μL within the first 3 months from the start of RT. Stepwise logistic regression analysis was used to determine the most important predictors of ASL. Results: Fifty-three patients (29%) developed ASL. Patients with ASL had significantly worse overall survival than those without (median: 12.5 vs 20.2 months, respectively, P<.001). Stepwise logistic regression analysis identified female sex (odds ratio [OR]: 5.30; 95% confidence interval [CI]: 2.46-11.41), older age (OR: 1.05; 95% CI: 1.02-1.09), lower baseline TLC (OR: 0.92; 95% CI: 0.87-0.98), and higher brain volume receiving 25 Gy (V{sub 25Gy}) (OR: 1.03; 95% CI: 1.003-1.05) as the most significant predictors for ASL. Brain V{sub 25Gy} <56% appeared to be the optimal threshold (OR: 2.36; 95% CI: 1.11-5.01), with an ASL rate of 38% versus 20% above and below this threshold, respectively (P=.006). Conclusions: Female sex, older age, lower baseline TLC, and higher brain V{sub 25Gy} are significant predictors of ASL during RT+TMZ therapy for HGG. Maintaining the V{sub 25Gy} of brain below 56% may reduce the risk of ASL.

  17. A dosimetric comparison of 3D conformal vs intensity modulated vs volumetric arc radiation therapy for muscle invasive bladder cancer

    Directory of Open Access Journals (Sweden)

    Foroudi Farshad

    2012-07-01

    Full Text Available Abstract Background To compare 3 Dimensional Conformal radiotherapy (3D-CRT with Intensity Modulated Radiotherapy (IMRT with Volumetric-Modulated Arc Therapy (VMAT for bladder cancer. Methods Radiotherapy plans for 15 patients with T2-T4N0M0 bladder cancer were prospectively developed for 3-DCRT, IMRT and VMAT using Varian Eclipse planning system. The same radiation therapist carried out all planning and the same clinical dosimetric constraints were used. 10 of the patients with well localised tumours had a simultaneous infield boost (SIB of the primary tumour planned for both IMRT and VMAT. Tumour control probabilities and normal tissue complication probabilities were calculated. Results Mean planning time for 3D-CRT, IMRT and VMAT was 30.0, 49.3, and 141.0 minutes respectively. The mean PTV conformity (CI index for 3D-CRT was 1.32, for IMRT 1.05, and for VMAT 1.05. The PTV Homogeneity (HI index was 0.080 for 3D-CRT, 0.073 for IMRT and 0.086 for VMAT. Tumour control and normal tissue complication probabilities were similar for 3D-CRT, IMRT and VMAT. The mean monitor units were 267 (range 250–293 for 3D-CRT; 824 (range 641–1083 for IMRT; and 403 (range 333–489 for VMAT (P  Conclusions VMAT is associated with similar dosimetric advantages as IMRT over 3D-CRT for muscle invasive bladder cancer. VMAT is associated with faster delivery times and less number of mean monitor units than IMRT. SIB is feasible in selected patients with localized tumours.

  18. Advanced Small Animal Conformal Radiation Therapy Device.

    Science.gov (United States)

    Sharma, Sunil; Narayanasamy, Ganesh; Przybyla, Beata; Webber, Jessica; Boerma, Marjan; Clarkson, Richard; Moros, Eduardo G; Corry, Peter M; Griffin, Robert J

    2017-02-01

    We have developed a small animal conformal radiation therapy device that provides a degree of geometrical/anatomical targeting comparable to what is achievable in a commercial animal irradiator. small animal conformal radiation therapy device is capable of producing precise and accurate conformal delivery of radiation to target as well as for imaging small animals. The small animal conformal radiation therapy device uses an X-ray tube, a robotic animal position system, and a digital imager. The system is in a steel enclosure with adequate lead shielding following National Council on Radiation Protection and Measurements 49 guidelines and verified with Geiger-Mueller survey meter. The X-ray source is calibrated following AAPM TG-61 specifications and mounted at 101.6 cm from the floor, which is a primary barrier. The X-ray tube is mounted on a custom-made "gantry" and has a special collimating assembly system that allows field size between 0.5 mm and 20 cm at isocenter. Three-dimensional imaging can be performed to aid target localization using the same X-ray source at custom settings and an in-house reconstruction software. The small animal conformal radiation therapy device thus provides an excellent integrated system to promote translational research in radiation oncology in an academic laboratory. The purpose of this article is to review shielding and dosimetric measurement and highlight a few successful studies that have been performed to date with our system. In addition, an example of new data from an in vivo rat model of breast cancer is presented in which spatially fractionated radiation alone and in combination with thermal ablation was applied and the therapeutic benefit examined.

  19. Quality assurance study for dosimetry of Radiation Therapy equipment in Saudi Arabia

    International Nuclear Information System (INIS)

    Al-Mokhlef, Jazi M.; Nabaz, Noori

    2003-01-01

    International standards address the accuracy of dose delivery for radiation therapy machines as well as quality assurance and staffing levels for radiation therapy centers. We performed absolute calibrations of gamma ,X-ray and electron radiotherapy beams in all radiation therapy centers in Saudi Arabia. We also assessed quality assurance and staffing levels Dosimetric measurements were made with a portable dosimetry system, which consisted of a calibrated Farmer ionization chamber and an electrometer, small water phantom, barometer and thermometer. Differences between the measured and the expected output (c Gy/MU or c Gy/min) were found to be in the range of -11%+5%. About 17% of radiotherapy beams were not within the acceptable tolerance level (+/-3%). Quality assurance in some radiation centers was poor and staffing levels were inadequate. We found poor compliance with internationally accepted tolerance levels for dose calibration of radiotherapy beams at radiation therapy centers in Saudi Arabia. Analysis of medical physics staffing revealed severe discrepancies from those recommended by international guidelines .We recommend that radiation therapy centers be adequately staffed with qualified medical physics personnel and that periodic audit programs be required a governmental body. (author)

  20. A concept of radiation safety in radiodiagnosis and radiotherapy

    International Nuclear Information System (INIS)

    Stavitskij, R.V.; Vasil'ev, V.N.; Lebedev, L.A.; Blinov, N.N.

    1991-01-01

    Conceptual problems of up to date radiation safety dosimetric ensurance in radiation diagnostics and radiotherapy of nontumor diseases are as follows: selection of dosimetric criteria of nonequilibrium radiation influence with an account of probable remote radiation aftereffects; determination of dose-response dependence character by low radiation doses; development of optimal technological principles for radiation diagnostics and therapy; development of organizational and methodical approaches to decreasing dose loads by radiation diagnostics and therapy of nontumor diseases; optimization of studies by ALARA principle

  1. Dosimetric Impact of the Interplay Effect During Stereotactic Lung Radiation Therapy Delivery Using Flattening Filter-Free Beams and Volumetric Modulated Arc Therapy

    International Nuclear Information System (INIS)

    Ong, Chin Loon; Dahele, Max; Slotman, Ben J.; Verbakel, Wilko F.A.R.

    2013-01-01

    Purpose: We investigated the dosimetric impact of the interplay effect during RapidArc stereotactic body radiation therapy for lung tumors using flattening filter-free (FFF) beams with different dose rates. Methods and Materials: Seven tumors with motion ≤20 mm, treated with 10-MV FFF RapidArc, were analyzed. A programmable phantom with sinusoidal longitudinal motion (30-mm diameter “tumor” insert; period = 5 s; individualized amplitude from planning 4-dimensional computed tomography) was used for dynamic dose measurements. Measurements were made with GafChromic EBT III films. Plans delivered the prescribed dose to 95% of the planning target volume, created by a 5-mm expansion of the internal target volume. They comprised 2 arcs and maximum dose rates of 400 and 2400 MU/min. For 2400 MU/min plans, measurements were repeated at 3 different initial breathing phases to model interplay over 2 to 3 fractions. For 3 cases, 2 extra plans were created using 1 full rotational arc (with contralateral lung avoidance sector) and 1 partial arc of 224° to 244°. Dynamic and convolved static measurements were compared by use of gamma analysis of 3% dose difference and 1 mm distance-to-agreement. Results: For 2-arc 2400 MU/min plans, maximum dose deviation of 9.4% was found in a single arc; 7.4% for 2 arcs (single fraction) and 99% of the area within the region of interest passed the gamma criteria when all 3 measurements with different initial phases were combined. Single-fraction single-arc plans showed higher dose deviations, which diminished when dose distributions were summed over 2 fractions. All 400 MU/min plans showed good agreement in a single fraction measurement. Conclusion: Under phantom conditions, single-arc and single-fraction 2400 MU/min FFF RapidArc lung stereotactic body radiation therapy is susceptible to interplay. Two arcs and ≥2 fractions reduced the effect to a level that appeared unlikely to be clinically significant

  2. Dosimetric evaluation of simultaneous integrated boost during stereotactic body radiation therapy for pancreatic cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Wensha, E-mail: wensha.yang@cshs.org [Department of Radiation Oncology, Cedars Sinai Medical Center, Los Angeles, CA (United States); Reznik, Robert; Fraass, Benedick A. [Department of Radiation Oncology, Cedars Sinai Medical Center, Los Angeles, CA (United States); Nissen, Nicholas [Department of Surgery, Cedars Sinai Medical Center, Los Angeles, CA (United States); Hendifar, Andrew [Department of Gastrointestinal Oncology, Cedars Sinai Medical Center, Los Angeles, CA (United States); Wachsman, Ashley [Department of Cross-Sectional Imaging Interventional Oncology, Cedars Sinai Medical Center, Los Angeles, CA (United States); Sandler, Howard; Tuli, Richard [Department of Radiation Oncology, Cedars Sinai Medical Center, Los Angeles, CA (United States)

    2015-04-01

    Stereotactic body radiation therapy (SBRT) provides a promising way to treat locally advanced pancreatic cancer and borderline resectable pancreatic cancer. A simultaneous integrated boost (SIB) to the region of vessel abutment or encasement during SBRT has the potential to downstage otherwise likely positive surgical margins. Despite the potential benefit of using SIB-SBRT, the ability to boost is limited by the local geometry of the organs at risk (OARs), such as stomach, duodenum, and bowel (SDB), relative to tumor. In this study, we have retrospectively replanned 20 patients with 25 Gy prescribed to the planning target volume (PTV) and 33~80 Gy to the boost target volume (BTV) using an SIB technique for all patients. The number of plans and patients able to satisfy a set of clinically established constraints is analyzed. The ability to boost vessels (within the gross target volume [GTV]) is shown to correlate with the overlap volume (OLV), defined to be the overlap between the GTV + a 1(OLV1)- or 2(OLV2)-cm margin with the union of SDB. Integral dose, boost dose contrast (BDC), biologically effective BDC, tumor control probability for BTV, and normal tissue complication probabilities are used to analyze the dosimetric results. More than 65% of the cases can deliver a boost to 40 Gy while satisfying all OAR constraints. An OLV2 of 100 cm{sup 3} is identified as the cutoff volume: for cases with OLV2 larger than 100 cm{sup 3}, it is very unlikely the case could achieve 25 Gy to the PTV while successfully meeting all the OAR constraints.

  3. Non-dosimetric quality assurance for the three-dimensional radiation treatment planning systems using a multi-leaf collimator phantom

    International Nuclear Information System (INIS)

    Tateoka, Kunihiko; Nagase, Daiki; Sato, Takahito; Shimizume, Kazunari; Ouchi, Atsushi; Nakata, Kensei; Hareyama, Masato

    2008-01-01

    Evaluation of errors and limitations in simulation software for three-dimensional radiation treatment systems (3D-RTPS) is an important issue. Non-dosimetric quality assurance (QA) of the simulation software of 3D-RTPS was evaluated by graphical displays of JAW and multi-leaf collimator (MLC) settings in a 3D-RTPS. The influence of observations made using the phantom depends on human errors and several parameters of the CT scan set, such as slice thickness and spacing, pixel size, partial volume effects and the reconstructed image orientation. We explored the methods that were minimally influenced by these errors and parameters. The QA phantom (MLC phantom) has been designed for checking a JAW and MLC settings in a 3D-RTPS is used for non-dosimetric QA. We analyzed the CT value of the boundary the structures of the MLC phantom. The relative CT value for thickness 1 mm slice in border of each structure body of MLC phantom respectively shows a decrease of about 2%, 4%, 10% by 2 mm, 3 mm and 5 mm. In case of thickness 5 mm slice, the mean deference of border of virtual radiation beams and phantom was 0.8 mm, and standard deviation of them was 0.6 mm. And the mean difference of border of a DRR image and phantom was 0.08 mm and the standard deviation of them 0.6 mm. In case of thickness 2 mm slice, the mean deference of border of virtual radiation beams and phantom was -0.18 mm, and standard deviation of them was 0.32 mm. And the mean difference of border of a DRR image and phantom was 0.87 mm and the standard deviation of them 0.54 mm. The result of the study is useful for improvement in a precision of non-dosimetric QA. Our method of non-dosimetric QA can minimize human error and influence of several parameters of the CT scan set. The MLC phantom is a useful tool in the QA of radiation therapy with application to 3D-RTPS, CT simulators, and virtual simulation packages with MLC display capabilities. (author)

  4. Ten years of a National Service of Dosimetric calibration at radiation protection

    International Nuclear Information System (INIS)

    Morales, J.A.; Jova, L.; Hernandez, E.; Campa, R.; Walwyn, G.

    1996-01-01

    Since 1986, the CPHR has offered a national service of calibration of dosimetric instruments at levels of radiation protection. The history of such a service is the chronology of efforts to reduce the uncertainties of the calibration process, expand the ranges of useful dose rates, and enhance the radiological safety when using the sources. The crowning of those efforts is the complement and start-up of the secondary la laboratory of dosimetric calibration (SLDC), which is currently a member of the IAEA/WHO. SLDC international network. As a result of this service, 256 instruments have been calibration and 867 personal dosimeters film badges and TLD and 72 environmental TLD dosimeters have been irradiated at known doses. The service rendered has benefited 62 national institutions which are users of ionizing radiations

  5. Dosimetric Advantages of Midventilation Compared With Internal Target Volume for Radiation Therapy of Pancreatic Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lens, Eelco, E-mail: e.lens@amc.uva.nl; Horst, Astrid van der; Versteijne, Eva; Tienhoven, Geertjan van; Bel, Arjan

    2015-07-01

    Purpose: The midventilation (midV) approach can be used to take respiratory-induced pancreatic tumor motion into account during radiation therapy. In this study, the dosimetric consequences for organs at risk and tumor coverage of using a midV approach compared with using an internal target volume (ITV) were investigated. Methods and Materials: For each of the 18 patients, 2 treatment plans (25 × 2.0 Gy) were created, 1 using an ITV and 1 using a midV approach. The midV dose distribution was blurred using the respiratory-induced motion from 4-dimensional computed tomography. The resulting planning target volume (PTV) coverage for this blurred dose distribution was analyzed; PTV coverage was required to be at least V{sub 95%} >98%. In addition, the change in PTV size and the changes in V{sub 10Gy}, V{sub 20Gy}, V{sub 30Gy}, V{sub 40Gy}, D{sub mean} and D{sub 2cc} for the stomach and for the duodenum were analyzed; differences were tested for significance using the Wilcoxon signed-rank test. Results: Using a midV approach resulted in sufficient target coverage. A highly significant PTV size reduction of 13.9% (P<.001) was observed. Also, all dose parameters for the stomach and duodenum, except the D{sub 2cc} of the duodenum, improved significantly (P≤.002). Conclusions: By using the midV approach to account for respiratory-induced tumor motion, a significant PTV reduction and significant dose reductions to the stomach and to the duodenum can be achieved when irradiating pancreatic tumors.

  6. Dosimetric Advantages of Midventilation Compared With Internal Target Volume for Radiation Therapy of Pancreatic Cancer

    International Nuclear Information System (INIS)

    Lens, Eelco; Horst, Astrid van der; Versteijne, Eva; Tienhoven, Geertjan van; Bel, Arjan

    2015-01-01

    Purpose: The midventilation (midV) approach can be used to take respiratory-induced pancreatic tumor motion into account during radiation therapy. In this study, the dosimetric consequences for organs at risk and tumor coverage of using a midV approach compared with using an internal target volume (ITV) were investigated. Methods and Materials: For each of the 18 patients, 2 treatment plans (25 × 2.0 Gy) were created, 1 using an ITV and 1 using a midV approach. The midV dose distribution was blurred using the respiratory-induced motion from 4-dimensional computed tomography. The resulting planning target volume (PTV) coverage for this blurred dose distribution was analyzed; PTV coverage was required to be at least V 95% >98%. In addition, the change in PTV size and the changes in V 10Gy , V 20Gy , V 30Gy , V 40Gy , D mean and D 2cc for the stomach and for the duodenum were analyzed; differences were tested for significance using the Wilcoxon signed-rank test. Results: Using a midV approach resulted in sufficient target coverage. A highly significant PTV size reduction of 13.9% (P<.001) was observed. Also, all dose parameters for the stomach and duodenum, except the D 2cc of the duodenum, improved significantly (P≤.002). Conclusions: By using the midV approach to account for respiratory-induced tumor motion, a significant PTV reduction and significant dose reductions to the stomach and to the duodenum can be achieved when irradiating pancreatic tumors

  7. Comparison study of the partial-breast irradiation techniques: Dosimetric analysis of three-dimensional conformal radiation therapy, electron beam therapy, and helical tomotherapy depending on various tumor locations

    International Nuclear Information System (INIS)

    Kim, Min-Joo; Park, So-Hyun; Son, Seok-Hyun; Cheon, Keum-Seong; Choi, Byung-Ock; Suh, Tae-Suk

    2013-01-01

    The partial-breast irradiation (PBI) technique, an alternative to whole-breast irradiation, is a beam delivery method that uses a limited range of treatment volume. The present study was designed to determine the optimal PBI treatment modalities for 8 different tumor locations. Treatment planning was performed on computed tomography (CT) data sets of 6 patients who had received lumpectomy treatments. Tumor locations were classified into 8 subsections according to breast quadrant and depth. Three-dimensional conformal radiation therapy (3D-CRT), electron beam therapy (ET), and helical tomotherapy (H-TOMO) were utilized to evaluate the dosimetric effect for each tumor location. Conformation number (CN), radical dose homogeneity index (rDHI), and dose delivered to healthy tissue were estimated. The Kruskal-Wallis, Mann-Whitney U, and Bonferroni tests were used for statistical analysis. The ET approach showed good sparing effects and acceptable target coverage for the lower inner quadrant—superficial (LIQ-S) and lower inner quadrant—deep (LIQ-D) locations. The H-TOMO method was the least effective technique as no evaluation index achieved superiority for all tumor locations except CN. The ET method is advisable for treating LIQ-S and LIQ-D tumors, as opposed to 3D-CRT or H-TOMO, because of acceptable target coverage and much lower dose applied to surrounding tissue

  8. The dosimetric effects of photon energy on the quality of prostate volumetric modulated arc therapy.

    Science.gov (United States)

    Mattes, Malcolm D; Tai, Cyril; Lee, Alvin; Ashamalla, Hani; Ikoro, N C

    2014-01-01

    Studies comparing the dosimetric effects of high- and low-energy photons to treat prostate cancer using 3-dimensional conformal and intensity modulated radiation therapy have yielded mixed results. With the advent of newer radiation delivery systems like volumetric modulated arc therapy (VMAT), the impact of changing photon energy is readdressed. Sixty-five patients treated for prostate cancer at our institution from 2011 to 2012 underwent CT simulation. A target volume encompassing the prostate and entire seminal vesicles was treated to 50.4 Gy, followed by a boost to the prostate and proximal seminal vesicles to a total dose of 81 Gy. The VMAT plans were generated for 6-MV and 10-MV photons under identical optimization conditions using the Eclipse system version 8.6 (Varian Medical Systems, Palo Alto, CA). The analytical anisotropic algorithm was used for all dose calculations. Plans were normalized such that 98% of the planning target volume (PTV) received 100% of the prescribed dose. Dose-volumetric data from the treatment planning system was recorded for both 6-MV and 10-MV plans, which were compared for both the entire cohort and subsets of patients stratified according to the anterior-posterior separation. Plans using 10-MV photons had statistically significantly lower relative integral dose (4.1%), gradient measure (4.1%), skin Dmax (16.9%), monitor units (13.0%), and bladder V(30) (3.1%) than plans using 6-MV photons (P photons was more pronounced for thicker patients (anterior-posterior separation >21 cm) for most parameters, with statistically significant differences in bladder V(30), bladder V(65), integral dose, conformity index, and monitor units. The main dosimetric benefits of 10-MV as compared with 6-MV photons are seen in thicker patients, though for the entire cohort 10-MV plans resulted in a lower integral dose, gradient measure, skin Dmax, monitor units, and bladder V(30), possibly at the expense of higher rectum V(81). Copyright © 2014

  9. Dosimetric investigation depending on tumor location in patient breast in partial breast irradiation

    International Nuclear Information System (INIS)

    Kim, Min Joo; Park, So Hyun; Jung, Joo Young; Woong, Cho; Suh, Tae Suk

    2012-01-01

    The Partial Breast Irradiation (PBI) technique, which involves radiation beam delivery techniques that use a limited range of treatment volumes, has been a challenging approach that is worthy of consideration compared to whole-breast radiation therapy (WBRT). Because of a small target volumes used in the PBI technique, the radiation dose can be safely delivered to the targeted tissue without the unwanted delivery of radiation to normal breast tissues and organ at risk (OAR), such as contralateral breast, lung and heart.Through PBI technique, better cosmetic outcomes and minimizing damages to OARs could be expected and also the daily dose can be increased with smaller number of fractionation in radiation therapy. The purpose of this study was to evaluate the dosimetric effects according to tumor locations in patient's breast for Partial Breast Irradiation (PBI) technique using three Dimensional Conformal Radiation Therapy (3DCRT), Electron Beam Radiation therapy (EBRT) and Helical-tomotherapy (H-TOMO). Dosimetric comparisons of PBI technique for 3DCRT, EBRT, and H-TOMO depending on the classified tumor locations were performed. H-TOMO delivered the low dose to lager volume to surrounding normal tissue, such as the heart and lungs compared to 3DCRT and EBRT although it had the same degree of target coverage as the other methods (3DCRT, EBRT). EBRT had a curative effect for early-stage breast cancers located in the lower and inner sections (LIQ-S, LIQ-D)

  10. Dosimetric and Clinical Outcomes With Intensity Modulated Radiation Therapy After Chemotherapy for Patients With Early-Stage Diffuse Large B-cell Lymphoma of Waldeyer Ring

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Yong-Gang; Qi, Shu-Nan; Wang, Shu-Lian; Liu, Yue-Ping; Wang, Wei-Hu; Jin, Jing; Song, Yong-Wen; Ren, Hua; Fang, Hui [Department of Radiation Oncology, Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing (China); He, Xiao-Hui; Dong, Mei [Department of Medical Oncology, Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing (China); Chen, Bo; Lu, Ning-Ning; Li, Ning; Tang, Yuan; Tang, Yu; Dai, Jian-Rong [Department of Radiation Oncology, Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing (China); Li, Ye-Xiong, E-mail: yexiong12@163.com [Department of Radiation Oncology, Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing (China)

    2016-10-01

    Purpose: To assess the dosimetric benefit, prognosis, and toxicity of intensity modulated radiation therapy (IMRT) for early-stage, diffuse large B-cell lymphoma of Waldeyer ring (WR-DLBCL). Methods and Materials: Sixty-one patients with early-stage WR-DLBCL who received chemotherapy followed by IMRT were retrospectively reviewed. Dosimetric parameters for the target volume and critical normal structures were evaluated, and survival was calculated. Linear regression analysis was used to assess the effect of the mean dose (D{sub mean}) to the parotid glands on xerostomia. Results: The median conformity index and homogeneity index of the planning target volume (PTV) were 0.83 and 0.90, respectively, demonstrating very good coverage of the target volume. The mean dose to the parotid glands was 24.9 Gy. The 5-year overall survival (OS), progression-free survival (PFS), and locoregional control (LRC) were 94.7%, 93.1%, and 98.3%, respectively. Early and late toxicities were mild, and no patient experienced late grade ≥3 toxicities. The D{sub mean} to the parotid glands had a linear correlation with late grade ≥2 xerostomia. Conclusions: IMRT after chemotherapy can provide excellent dose conformity and achieve favorable survival and LRC with mild toxicities in patients with early-stage WR-DLBCL. Dose constraints for the parotid glands should be limited to <24 Gy for early-stage WR-DLBCL.

  11. Adaptation of the present concept of dosimetric radiation protection quantities for external radiation to radiation protection practice

    International Nuclear Information System (INIS)

    Boehm, J.; Thompson, I. M. G.

    2004-01-01

    The present concept of dosimetric radiation protection quantities for external radiation is reviewed. For everyday application of the concept some adaptations are recommended. The check of the compliance with dose limits should be performed either by the comparison with values of the respective operational quantities directly or by the calculation of the protection quantity by means of the operational quantity, the appertaining conversion coefficient and additional information of the radiation field. Only four operational quantities are regarded to be sufficient for most applications in radiation protection practice. The term equivalent should be used in the connection dose equivalent only. Proposals are made for names of frequently used operational quantities which are denoted up to now by symbols only. (authors)

  12. Neo-adjuvant chemo-radiation of rectal cancer with Volumetric Modulated Arc Therapy: summary of technical and dosimetric features and early clinical experience

    International Nuclear Information System (INIS)

    Richetti, Antonella; Fogliata, Antonella; Clivio, Alessandro; Nicolini, Giorgia; Pesce, Gianfranco; Salati, Emanuela; Vanetti, Eugenio; Cozzi, Luca

    2010-01-01

    To report about initial technical and clinical experience in preoperative radiation treatment of rectal cancer with volumetric modulated arcs with the RapidArc ® (RA) technology. Twenty-five consecutive patients (pts) were treated with RA. All showed locally advanced rectal adenocarcinoma with stage T2-T4, N0-1. Dose prescription was 44 Gy in 22 fractions (or 45 Gy in 25 fractions). Delivery was performed with single arc with a 6 MV photon beam. Twenty patients were treated preoperatively, five did not receive surgery. Twenty-three patients received concomitant chemotherapy with oral capecitabine. A comparison with a cohort of twenty patients with similar characteristics treated with conformal therapy (3DC) is presented as well. From a dosimetric point of view, RA improved conformality of doses (CI 95% = 1.1 vs. 1.4 for RA and 3DC), presented similar target coverage with lower maximum doses, significant sparing of femurs and significant reduction of integral and mean dose to healthy tissue. From the clinical point of view, surgical reports resulted in a down-staging in 41% of cases. Acute toxicity was limited to Grade 1-2 diarrhoea in 40% and Grade 3 in 8% of RA pts, 45% and 5% of 3DC pts, compatible with known effects of concomitant chemotherapy. RA treatments were performed with an average of 2.0 vs. 3.4 min of 3DC. RA proved to be a safe, qualitatively advantageous treatment modality for rectal cancer, showing some improved results in dosimetric aspects

  13. Neo-adjuvant chemo-radiation of rectal cancer with Volumetric Modulated Arc Therapy: summary of technical and dosimetric features and early clinical experience

    Directory of Open Access Journals (Sweden)

    Salati Emanuela

    2010-02-01

    Full Text Available Abstract Background To report about initial technical and clinical experience in preoperative radiation treatment of rectal cancer with volumetric modulated arcs with the RapidArc® (RA technology. Methods Twenty-five consecutive patients (pts were treated with RA. All showed locally advanced rectal adenocarcinoma with stage T2-T4, N0-1. Dose prescription was 44 Gy in 22 fractions (or 45 Gy in 25 fractions. Delivery was performed with single arc with a 6 MV photon beam. Twenty patients were treated preoperatively, five did not receive surgery. Twenty-three patients received concomitant chemotherapy with oral capecitabine. A comparison with a cohort of twenty patients with similar characteristics treated with conformal therapy (3DC is presented as well. Results From a dosimetric point of view, RA improved conformality of doses (CI95% = 1.1 vs. 1.4 for RA and 3DC, presented similar target coverage with lower maximum doses, significant sparing of femurs and significant reduction of integral and mean dose to healthy tissue. From the clinical point of view, surgical reports resulted in a down-staging in 41% of cases. Acute toxicity was limited to Grade 1-2 diarrhoea in 40% and Grade 3 in 8% of RA pts, 45% and 5% of 3DC pts, compatible with known effects of concomitant chemotherapy. RA treatments were performed with an average of 2.0 vs. 3.4 min of 3DC. Conclusion RA proved to be a safe, qualitatively advantageous treatment modality for rectal cancer, showing some improved results in dosimetric aspects.

  14. SU-E-P-58: Dosimetric Study of Conventional Intensity-Modulated Radiotherapy and Knowledge-Based Radiation Therapy for Postoperation of Cervix Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ma, C; Yin, Y [Shandong Tumor Hospital, Jinan, Shandong Provice (China)

    2015-06-15

    Purpose: To compare the dosimetric difference of the target volume and organs at risk(OARs) between conventional intensity-modulated radiotherapy(C-IMRT) and knowledge-based radiation therapy (KBRT) plans for cervix cancer. Methods: 39 patients with cervical cancer after surgery were randomly selected, 20 patient plans were used to create the model, the other 19 cases used for comparative evaluation. All plans were designed in Eclipse system. The prescription dose was 30.6Gy, 17 fractions, OARs dose satisfied to the clinical requirement. A paired t test was used to evaluate the differences of dose-volume histograms (DVH). Results: Comparaed to C-IMRT plan, the KBRT plan target can achieve the similar target dose coverage, D98,D95,D2,HI and CI had no difference (P≥0.05). The dose of rectum, bladder and femoral heads had no significant differences(P≥0.05). The time was used to design treatment plan was significant reduced. Conclusion: This study shows that postoperative radiotherapy of cervical KBRT plans can achieve the similar target and OARs dose, but the shorter designing time.

  15. SU-E-T-338: Dosimetric Study of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiation Therapy (IMRT) for Stereotactic Body Radiation Therapy (SBRT) in Early Stage Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, I; Quinn, K; Seebach, A; Wang, H [OSF Saint Anthony Medical Center, Rockford, IL (United States); Yah, R [University of Illinois College of Medicine at Rockford, Rockford, IL (United States)

    2015-06-15

    Purpose: This study evaluates the dosimetric differences using volumetric modulated arc therapy (VMAT) in patients previously treated with intensity modulated radiation therapy IMRT for stereotactic body radiotherapy (SBRT) in early stage lung cancer. Methods: We evaluated 9 consecutive medically inoperable lung cancer patients at the start of the SBRT program who were treated with IMRT from November 2010 to October 2011. These patients were treated using 6 MV energy. The 9 cases were then re-planned with VMAT performed with arc therapy using 6 MV flattening filter free (FFF) energy with the same organs at risk (OARS) constraints. Data collected for the treatment plans included target coverage, beam on time, dose to OARS and gamma pass rate. Results: Five patients were T1N0 and four patients were T2N0 with all tumors less than 5 cm. The average GTV was 13.02 cm3 (0.83–40.87) and average PTV was 44.65 cm3 (14.06–118.08). The IMRT plans had a mean of 7.2 angles (6–9) and 5.4 minutes (3.6–11.1) per plan. The VMAT plans had a mean of 2.8 arcs (2–3) and 4.0 minutes (2.2–6.0) per plan. VMAT had slightly more target coverage than IMRT with average increase in D95 of 2.68% (1.24–5.73) and D99 of 3.65% (0.88–8.77). VMAT produced lower doses to all OARs. The largest reductions were in maximum doses to the spinal cord with an average reduction of 24.1%, esophagus with an average reduction of 22.1%, and lung with an average reduction in the V20 of 16.3% The mean gamma pass rate was 99.8% (99.2–100) at 3 mm and 3% for VMAT with comparable values for IMRT. Conclusion: These findings suggest that using VMAT for SBRT in early stage lung cancer is superior to IMRT in terms of dose coverage, OAR dose and a lower treatment delivery time with a similar gamma pass rate.

  16. Postoperative telegammatherapy of breast cancer (Dosimetric studies)

    Energy Technology Data Exchange (ETDEWEB)

    Todorov, J; Mitrov, G [Nauchno-Izsledovatelski Onkologichen Inst., Sofia (Bulgaria); Konstantinov, B; Dobrev, D [Meditsinska Akademiya, Sofia (Bulgaria). Nauchen Inst. po Rentgenologiya i Radiobiologiya

    1977-01-01

    The method employed for postoperative radiation therapy of breast cancer at the Radiologic Clinic of the Medical Academy in Sofia is described. Results are reported and discussed of dosimetric studies carried out with the T-100 on heterogeneous tissue-equivalent Rando phantom for dose distributions in the regional lymph basin and the underlying tissues and organs. The results show coincidence between calculated and measured doses in the regional lymph basin and the thoracic wall. It was demonstrated that maximal radiation loading (3600 to 5500 rad) occurs in the apical and the hilar lung area.

  17. Dosimetric analysis of the alopecia preventing effect of hippocampus sparing whole brain radiation therapy

    International Nuclear Information System (INIS)

    Mahadevan, Anand; Sampson, Carrie; LaRosa, Salvatore; Floyd, Scott R.; Wong, Eric T.; Uhlmann, Erik J.; Sengupta, Soma; Kasper, Ekkehard M.

    2015-01-01

    Whole brain radiation therapy (WBRT) is widely used for the treatment of brain metastases. Cognitive decline and alopecia are recognized adverse effects of WBRT. Recently hippocampus sparing whole brain radiation therapy (HS-WBRT) has been shown to reduce the incidence of memory loss. In this study, we found that multi-field intensity modulated radiation therapy (IMRT), with strict constraints to the brain parenchyma and to the hippocampus, reduces follicular scalp dose and prevents alopecia. Suitable patients befitting the inclusion criteria of the RTOG 0933 trial received Hippocampus sparing whole brain radiation. On follow up, they were noticed to have full scalp hair preservation. 5 mm thickness of follicle bearing scalp in the radiation field was outlined in the planning CT scans. Conventional opposed lateral WBRT radiation fields were applied to these patient-specific image sets and planned with the same nominal dose of 30 Gy in 10 fractions. The mean and maximum dose to follicle bearing skin and Dose Volume Histogram (DVH) data were analyzed for conventional and HS-WBRT. Paired t-test was used to compare the means. All six patients had fully preserved scalp hair and remained clinically cognitively intact 1–3 months after HS-WBRT. Compared to conventional WBRT, in addition to the intended sparing of the Hippocampus, HS-WBRT delivered significantly lower mean dose (22.42 cGy vs. 16.33 cGy, p < 0.0001), V 24 (9 cc vs. 44 cc, p < 0.0000) and V 30 (9 cc vs. 0.096 cc, p = 0.0106) to follicle hair bearing scalp and prevented alopecia. There were no recurrences in the Hippocampus area. HS-WBRT, with an 11-field set up as described, while attempting to conserve hippocampus radiation and maintain radiation dose to brain inadvertently spares follicle-bearing scalp and prevents alopecia

  18. WE-D-BRD-01: Innovation in Radiation Therapy Delivery: Advanced Digital Linac Features

    International Nuclear Information System (INIS)

    Xing, L; Wong, J; Li, R

    2014-01-01

    Last few years has witnessed significant advances in linac technology and therapeutic dose delivery method. Digital linacs equipped with high dose rate FFF beams have been clinically implemented in a number of hospitals. Gated VMAT is becoming increasingly popular in treating tumors affected by respiratory motion. This session is devoted to update the audience with these technical advances and to present our experience in clinically implementing the new linacs and dose delivery methods. Topics to be covered include, technical features of new generation of linacs from different vendors, dosimetric characteristics and clinical need for FFF-beam based IMRT and VMAT, respiration-gated VMAT, the concept and implementation of station parameter optimized radiation therapy (SPORT), beam level imaging and onboard image guidance tools. Emphasis will be on providing fundamental understanding of the new treatment delivery and image guidance strategies, control systems, and the associated dosimetric characteristics. Commissioning and acceptance experience on these new treatment delivery technologies will be reported. Clinical experience and challenges encountered during the process of implementation of the new treatment techniques and future applications of the systems will also be highlighted. Learning Objectives: Present background knowledge of emerging digital linacs and summarize their key geometric and dosimetric features. SPORT as an emerging radiation therapy modality specifically designed to take advantage of digital linacs. Discuss issues related to the acceptance and commissioning of the digital linacs and FFF beams. Describe clinical utility of the new generation of digital linacs and their future applications

  19. WE-D-BRD-01: Innovation in Radiation Therapy Delivery: Advanced Digital Linac Features

    Energy Technology Data Exchange (ETDEWEB)

    Xing, L [Stanford University, Stanford, CA (United States); Wong, J [Johns Hopkins University, Baltimore, MD (United States); Li, R [Stanford University, Palo Alto, CA (United States)

    2014-06-15

    Last few years has witnessed significant advances in linac technology and therapeutic dose delivery method. Digital linacs equipped with high dose rate FFF beams have been clinically implemented in a number of hospitals. Gated VMAT is becoming increasingly popular in treating tumors affected by respiratory motion. This session is devoted to update the audience with these technical advances and to present our experience in clinically implementing the new linacs and dose delivery methods. Topics to be covered include, technical features of new generation of linacs from different vendors, dosimetric characteristics and clinical need for FFF-beam based IMRT and VMAT, respiration-gated VMAT, the concept and implementation of station parameter optimized radiation therapy (SPORT), beam level imaging and onboard image guidance tools. Emphasis will be on providing fundamental understanding of the new treatment delivery and image guidance strategies, control systems, and the associated dosimetric characteristics. Commissioning and acceptance experience on these new treatment delivery technologies will be reported. Clinical experience and challenges encountered during the process of implementation of the new treatment techniques and future applications of the systems will also be highlighted. Learning Objectives: Present background knowledge of emerging digital linacs and summarize their key geometric and dosimetric features. SPORT as an emerging radiation therapy modality specifically designed to take advantage of digital linacs. Discuss issues related to the acceptance and commissioning of the digital linacs and FFF beams. Describe clinical utility of the new generation of digital linacs and their future applications.

  20. Dosimetric feasibility of magnetic resonance imaging-guided tri-cobalt 60 preoperative intensity modulated radiation therapy for soft tissue sarcomas of the extremity.

    Science.gov (United States)

    Kishan, Amar U; Cao, Minsong; Mikaeilian, Argin G; Low, Daniel A; Kupelian, Patrick A; Steinberg, Michael L; Kamrava, Mitchell

    2015-01-01

    The purpose of this study was to investigate the dosimetric differences of delivering preoperative intensity modulated radiation therapy (IMRT) to patients with soft tissue sarcomas of the extremity (ESTS) with a teletherapy system equipped with 3 rotating (60)Co sources and a built-in magnetic resonance imaging and with standard linear accelerator (LINAC)-based IMRT. The primary study population consisted of 9 patients treated with preoperative radiation for ESTS between 2008 and 2014 with LINAC-based static field IMRT. LINAC plans were designed to deliver 50 Gy in 25 fractions to 95% of the planning target volume (PTV). Tri-(60)Co system IMRT plans were designed with ViewRay system software. Tri-(60)Co-based IMRT plans achieved equivalent target coverage and dosimetry for organs at risk (long bone, skin, and skin corridor) compared with LINAC-based IMRT plans. The maximum and minimum PTV doses, heterogeneity indices, and ratio of the dose to 50% of the volume were equivalent for both planning systems. One LINAC plan violated the maximum bone dose constraint, whereas none of the tri-(60)Co plans did. Using a tri-(60)Co system, we were able to achieve equivalent dosimetry to the PTV and organs at risk for patients with ESTS compared with LINAC-based IMRT plans. The tri-(60)Co system may be advantageous over current treatment platforms by allowing PTV reduction and by elimination of the additional radiation dose associated with daily image guidance, but this needs to be evaluated prospectively. Copyright © 2015 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  1. Toward a nomenclature and dosimetric scheme applicable to all radiations

    Energy Technology Data Exchange (ETDEWEB)

    Rupert, C S; Latarjet, R [Texas Univ., Dallas (USA)

    1978-07-01

    An informal Joint Working Group on Radiation Quantities, consisting of representatives of the ICRU and other international organizations was initiated at the International Congress of Radiation Research in 1974. The conclusions of a meeting of the Group held in 1975 are summarised. Quantities are proposed to describe any type of radiation field in terms of the total amount of energy carried by the radiation and its distribution with respect to time, area, volume and solid angle, expressed in terms of either radiant energy (joules) or number of particles. If this general approach is agreed to by the parent organizations and others the Group will go on to recommend quantities to represent the interactions of fields with matter and to provide a dosimetric scheme usable with all types of radiation.

  2. Postoperative Intensity Modulated Radiation Therapy in High Risk Prostate Cancer: A Dosimetric Comparison

    International Nuclear Information System (INIS)

    Digesu, Cinzia; Cilla, Savino; De Gaetano, Andrea; Massaccesi, Mariangela; Macchia, Gabriella; Ippolito, Edy; Deodato, Francesco; Panunzi, Simona; Iapalucci, Chiara; Mattiucci, Gian Carlo; D'Angelo, Elisa; Padula, Gilbert D.A.; Valentini, Vincenzo; Cellini, Numa

    2011-01-01

    The aim of this study was to compare intensity-modulated radiation therapy (IMRT) with 3D conformal technique (3D-CRT), with respect to target coverage and irradiation of organs at risk for high dose postoperative radiotherapy (PORT) of the prostate fossa. 3D-CRT and IMRT treatment plans were compared with respect to dose to the rectum and bladder. The dosimetric comparison was carried out in 15 patients considering 2 different scenarios: (1) exclusive prostate fossa irradiation, and (2) pelvic node irradiation followed by a boost on the prostate fossa. In scenario (1), a 3D-CRT plan (box technique) and an IMRT plan were calculated and compared for each patient. In scenario (2), 3 treatment plans were calculated and compared for each patient: (a) 3D-CRT box technique for both pelvic (prophylactic nodal irradiation) and prostate fossa irradiation (3D-CRT only); (b) 3D-CRT box technique for pelvic irradiation followed by an IMRT boost to the prostatic fossa (hybrid 3D-CRT and IMRT); and (c) IMRT for both pelvic and prostate fossa irradiation (IMRT only). For exclusive prostate fossa irradiation, IMRT significantly reduced the dose to the rectum (lower Dmean, V50%, V75%, V90%, V100%, EUD, and NTCP) and the bladder (lower Dmean, V50%, V90%, EUD and NTCP). When prophylactic irradiation of the pelvis was also considered, plan C (IMRT only) performed better than plan B (hybrid 3D-CRT and IMRT) as respect to both rectum and bladder irradiation (reduction of Dmean, V50%, V75%, V90%, equivalent uniform dose [EUD], and normal tissue complication probability [NTCP]). Plan (b) (hybrid 3D-CRT and IMRT) performed better than plan (a) (3D-CRT only) with respect to dose to the rectum (lower Dmean, V75%, V90%, V100%, EUD, and NTCP) and the bladder (Dmean, EUD, and NTCP). Postoperative IMRT in prostate cancer significantly reduces rectum and bladder irradiation compared with 3D-CRT.

  3. Amorphous chalcogenide semiconductors for solid state dosimetric systems of high-energetic ionizing radiation

    International Nuclear Information System (INIS)

    Shpotyuk, O.

    1997-01-01

    The application possibilities of amorphous chalcogenide semiconductors use as radiation-sensitive elements of high-energetic (E > 1 MeV) dosimetric systems are analysed. It is shown that investigated materials are characterized by more wide region of registered absorbed doses and low temperature threshold of radiation information bleaching in comparison with well-known analogies based on coloring oxide glasses. (author)

  4. Dosimetric impact of a CT metal artefact suppression algorithm for proton, electron and photon therapies

    International Nuclear Information System (INIS)

    Wei Jikun; Sandison, George A; Hsi, W-C; Ringor, Michael; Lu Xiaoyi

    2006-01-01

    Accurate dose calculation is essential to precision radiation treatment planning and this accuracy depends upon anatomic and tissue electron density information. Modern treatment planning inhomogeneity corrections use x-ray CT images and calibrated scales of tissue CT number to electron density to provide this information. The presence of metal in the volume scanned by an x-ray CT scanner causes metal induced image artefacts that influence CT numbers and thereby introduce errors in the radiation dose distribution calculated. This paper investigates the dosimetric improvement achieved by a previously proposed x-ray CT metal artefact suppression technique when the suppressed images of a patient with bilateral hip prostheses are used in commercial treatment planning systems for proton, electron or photon therapies. For all these beam types, this clinical image and treatment planning study reveals that the target may be severely underdosed if a metal artefact-contaminated image is used for dose calculations instead of the artefact suppressed one. Of the three beam types studied, the metal artefact suppression is most important for proton therapy dose calculations, intermediate for electron therapy and least important for x-ray therapy but still significant. The study of a water phantom having a metal rod simulating a hip prosthesis indicates that CT numbers generated after image processing for metal artefact suppression are accurate and thus dose calculations based on the metal artefact suppressed images will be of high fidelity

  5. Near Real-Time Assessment of Anatomic and Dosimetric Variations for Head and Neck Radiation Therapy via Graphics Processing Unit–based Dose Deformation Framework

    Energy Technology Data Exchange (ETDEWEB)

    Qi, X. Sharon, E-mail: xqi@mednet.ucla.edu [Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California (United States); Santhanam, Anand; Neylon, John; Min, Yugang; Armstrong, Tess; Sheng, Ke [Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California (United States); Staton, Robert J.; Pukala, Jason [Department of Radiation Oncology, UF Health Cancer Center - Orlando Health, Orlando, Florida (United States); Pham, Andrew; Low, Daniel A.; Lee, Steve P. [Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California (United States); Steinberg, Michael; Manon, Rafael [Department of Radiation Oncology, UF Health Cancer Center - Orlando Health, Orlando, Florida (United States); Chen, Allen M.; Kupelian, Patrick [Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California (United States)

    2015-06-01

    Purpose: The purpose of this study was to systematically monitor anatomic variations and their dosimetric consequences during intensity modulated radiation therapy (IMRT) for head and neck (H&N) cancer by using a graphics processing unit (GPU)-based deformable image registration (DIR) framework. Methods and Materials: Eleven IMRT H&N patients undergoing IMRT with daily megavoltage computed tomography (CT) and weekly kilovoltage CT (kVCT) scans were included in this analysis. Pretreatment kVCTs were automatically registered with their corresponding planning CTs through a GPU-based DIR framework. The deformation of each contoured structure in the H&N region was computed to account for nonrigid change in the patient setup. The Jacobian determinant of the planning target volumes and the surrounding critical structures were used to quantify anatomical volume changes. The actual delivered dose was calculated accounting for the organ deformation. The dose distribution uncertainties due to registration errors were estimated using a landmark-based gamma evaluation. Results: Dramatic interfractional anatomic changes were observed. During the treatment course of 6 to 7 weeks, the parotid gland volumes changed up to 34.7%, and the center-of-mass displacement of the 2 parotid glands varied in the range of 0.9 to 8.8 mm. For the primary treatment volume, the cumulative minimum and mean and equivalent uniform doses assessed by the weekly kVCTs were lower than the planned doses by up to 14.9% (P=.14), 2% (P=.39), and 7.3% (P=.05), respectively. The cumulative mean doses were significantly higher than the planned dose for the left parotid (P=.03) and right parotid glands (P=.006). The computation including DIR and dose accumulation was ultrafast (∼45 seconds) with registration accuracy at the subvoxel level. Conclusions: A systematic analysis of anatomic variations in the H&N region and their dosimetric consequences is critical in improving treatment efficacy. Nearly real

  6. Amorphous chalcogenide semiconductors for solid state dosimetric systems of high-energetic ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Shpotyuk, O. [Pedagogical University, Czestochowa (Poland)]|[Institute of Materials, Lvov (Ukraine)

    1997-12-31

    The application possibilities of amorphous chalcogenide semiconductors use as radiation-sensitive elements of high-energetic (E > 1 MeV) dosimetric systems are analysed. It is shown that investigated materials are characterized by more wide region of registered absorbed doses and low temperature threshold of radiation information bleaching in comparison with well-known analogies based on coloring oxide glasses. (author). 16 refs, 1 tab.

  7. Carcinoma of the anal canal: Intensity modulated radiation therapy (IMRT) versus three-dimensional conformal radiation therapy (3DCRT)

    Science.gov (United States)

    Sale, Charlotte; Moloney, Phillip; Mathlum, Maitham

    2013-01-01

    Introduction Patients with anal canal carcinoma treated with standard conformal radiotherapy frequently experience severe acute and late toxicity reactions to the treatment area. Roohipour et al. (Dis Colon Rectum 2008; 51: 147–53) stated a patient's tolerance of chemoradiation to be an important prediction of treatment success. A new intensity modulated radiation therapy (IMRT) technique for anal carcinoma cases has been developed at the Andrew Love Cancer Centre aimed at reducing radiation to surrounding healthy tissue. Methods A same-subject repeated measures design was used for this study, where five anal carcinoma cases at the Andrew Love Cancer Centre were selected. Conformal and IMRT plans were generated and dosimetric evaluations were performed. Each plan was prescribed a total of 54 Gray (Gy) over a course of 30 fractions to the primary site. Results The IMRT plans resulted in improved dosimetry to the planning target volume (PTV) and reduction in radiation to the critical structures (bladder, external genitalia and femoral heads). Statistically there was no difference between the IMRT and conformal plans in the dose to the small and large bowel; however, the bowel IMRT dose–volume histogram (DVH) doses were consistently lower. Conclusion The IMRT plans were superior to the conformal plans with improved dose conformity and reduced radiation to the surrounding healthy tissue. Anecdotally it was found that patients tolerated the IMRT treatment better than the three-dimensional (3D) conformal radiation therapy. This study describes and compares the planning techniques. PMID:26229623

  8. Carcinoma of the anal canal: Intensity modulated radiation therapy (IMRT) versus three-dimensional conformal radiation therapy (3DCRT)

    International Nuclear Information System (INIS)

    Sale, Charlotte; Moloney, Phillip; Mathlum, Maitham

    2013-01-01

    Patients with anal canal carcinoma treated with standard conformal radiotherapy frequently experience severe acute and late toxicity reactions to the treatment area. Roohipour et al. (Dis Colon Rectum 2008; 51: 147–53) stated a patient's tolerance of chemoradiation to be an important prediction of treatment success. A new intensity modulated radiation therapy (IMRT) technique for anal carcinoma cases has been developed at the Andrew Love Cancer Centre aimed at reducing radiation to surrounding healthy tissue. A same-subject repeated measures design was used for this study, where five anal carcinoma cases at the Andrew Love Cancer Centre were selected. Conformal and IMRT plans were generated and dosimetric evaluations were performed. Each plan was prescribed a total of 54 Gray (Gy) over a course of 30 fractions to the primary site. The IMRT plans resulted in improved dosimetry to the planning target volume (PTV) and reduction in radiation to the critical structures (bladder, external genitalia and femoral heads). Statistically there was no difference between the IMRT and conformal plans in the dose to the small and large bowel; however, the bowel IMRT dose–volume histogram (DVH) doses were consistently lower. The IMRT plans were superior to the conformal plans with improved dose conformity and reduced radiation to the surrounding healthy tissue. Anecdotally it was found that patients tolerated the IMRT treatment better than the three-dimensional (3D) conformal radiation therapy. This study describes and compares the planning techniques

  9. Carcinoma of the anal canal: Intensity modulated radiation therapy (IMRT) versus three-dimensional conformal radiation therapy (3DCRT).

    Science.gov (United States)

    Sale, Charlotte; Moloney, Phillip; Mathlum, Maitham

    2013-12-01

    Patients with anal canal carcinoma treated with standard conformal radiotherapy frequently experience severe acute and late toxicity reactions to the treatment area. Roohipour et al. (Dis Colon Rectum 2008; 51: 147-53) stated a patient's tolerance of chemoradiation to be an important prediction of treatment success. A new intensity modulated radiation therapy (IMRT) technique for anal carcinoma cases has been developed at the Andrew Love Cancer Centre aimed at reducing radiation to surrounding healthy tissue. A same-subject repeated measures design was used for this study, where five anal carcinoma cases at the Andrew Love Cancer Centre were selected. Conformal and IMRT plans were generated and dosimetric evaluations were performed. Each plan was prescribed a total of 54 Gray (Gy) over a course of 30 fractions to the primary site. The IMRT plans resulted in improved dosimetry to the planning target volume (PTV) and reduction in radiation to the critical structures (bladder, external genitalia and femoral heads). Statistically there was no difference between the IMRT and conformal plans in the dose to the small and large bowel; however, the bowel IMRT dose-volume histogram (DVH) doses were consistently lower. The IMRT plans were superior to the conformal plans with improved dose conformity and reduced radiation to the surrounding healthy tissue. Anecdotally it was found that patients tolerated the IMRT treatment better than the three-dimensional (3D) conformal radiation therapy. This study describes and compares the planning techniques.

  10. Carcinoma of the anal canal: Intensity modulated radiation therapy (IMRT) versus three-dimensional conformal radiation therapy (3DCRT)

    Energy Technology Data Exchange (ETDEWEB)

    Sale, Charlotte; Moloney, Phillip; Mathlum, Maitham [Andrew Love Cancer Centre, Geelong Hospital, Geelong, Victoria (Australia)

    2013-12-15

    Patients with anal canal carcinoma treated with standard conformal radiotherapy frequently experience severe acute and late toxicity reactions to the treatment area. Roohipour et al. (Dis Colon Rectum 2008; 51: 147–53) stated a patient's tolerance of chemoradiation to be an important prediction of treatment success. A new intensity modulated radiation therapy (IMRT) technique for anal carcinoma cases has been developed at the Andrew Love Cancer Centre aimed at reducing radiation to surrounding healthy tissue. A same-subject repeated measures design was used for this study, where five anal carcinoma cases at the Andrew Love Cancer Centre were selected. Conformal and IMRT plans were generated and dosimetric evaluations were performed. Each plan was prescribed a total of 54 Gray (Gy) over a course of 30 fractions to the primary site. The IMRT plans resulted in improved dosimetry to the planning target volume (PTV) and reduction in radiation to the critical structures (bladder, external genitalia and femoral heads). Statistically there was no difference between the IMRT and conformal plans in the dose to the small and large bowel; however, the bowel IMRT dose–volume histogram (DVH) doses were consistently lower. The IMRT plans were superior to the conformal plans with improved dose conformity and reduced radiation to the surrounding healthy tissue. Anecdotally it was found that patients tolerated the IMRT treatment better than the three-dimensional (3D) conformal radiation therapy. This study describes and compares the planning techniques.

  11. Combining Physical and Biologic Parameters to Predict Radiation-Induced Lung Toxicity in Patients With Non-Small-Cell Lung Cancer Treated With Definitive Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Stenmark, Matthew H. [Department of Radiation Oncology, University of Michigan Medical Center, Ann Arbor, Michigan (United States); Cai Xuwei [Department of Radiation Oncology, University of Michigan Medical Center, Ann Arbor, Michigan (United States); Radiation Oncology, Shanghai Cancer Hospital, Fudan University, Shanghai (China); Shedden, Kerby [Department of Biostatistics, University of Michigan Medical Center, Ann Arbor, Michigan (United States); Hayman, James A. [Department of Radiation Oncology, University of Michigan Medical Center, Ann Arbor, Michigan (United States); Yuan Shuanghu [Department of Radiation Oncology, University of Michigan Medical Center, Ann Arbor, Michigan (United States); Radiation Oncology, Shangdong Cancer Hospital, Jinan (China); Ritter, Timothy [Veterans Affairs Medical Center, Ann Arbor, Michigan (United States); Ten Haken, Randall K.; Lawrence, Theodore S. [Department of Radiation Oncology, University of Michigan Medical Center, Ann Arbor, Michigan (United States); Kong Fengming, E-mail: fengkong@med.umich.edu [Department of Radiation Oncology, University of Michigan Medical Center, Ann Arbor, Michigan (United States); Veterans Affairs Medical Center, Ann Arbor, Michigan (United States)

    2012-10-01

    Purpose: To investigate the plasma dynamics of 5 proinflammatory/fibrogenic cytokines, including interleukin-1beta (IL-1{beta}), IL-6, IL-8, tumor necrosis factor alpha (TNF-{alpha}), and transforming growth factor beta1 (TGF-{beta}1) to ascertain their value in predicting radiation-induced lung toxicity (RILT), both individually and in combination with physical dosimetric parameters. Methods and Materials: Treatments of patients receiving definitive conventionally fractionated radiation therapy (RT) on clinical trial for inoperable stages I-III lung cancer were prospectively evaluated. Circulating cytokine levels were measured prior to and at weeks 2 and 4 during RT. The primary endpoint was symptomatic RILT, defined as grade 2 and higher radiation pneumonitis or symptomatic pulmonary fibrosis. Minimum follow-up was 18 months. Results: Of 58 eligible patients, 10 (17.2%) patients developed RILT. Lower pretreatment IL-8 levels were significantly correlated with development of RILT, while radiation-induced elevations of TGF-ss1 were weakly correlated with RILT. Significant correlations were not found for any of the remaining 3 cytokines or for any clinical or dosimetric parameters. Using receiver operator characteristic curves for predictive risk assessment modeling, we found both individual cytokines and dosimetric parameters were poor independent predictors of RILT. However, combining IL-8, TGF-ss1, and mean lung dose into a single model yielded an improved predictive ability (P<.001) compared to either variable alone. Conclusions: Combining inflammatory cytokines with physical dosimetric factors may provide a more accurate model for RILT prediction. Future study with a larger number of cases and events is needed to validate such findings.

  12. Dosimetric analysis of testicular doses in prostate intensity-modulated and volumetric-modulated arc radiation therapy at different energy levels

    Energy Technology Data Exchange (ETDEWEB)

    Onal, Cem, E-mail: hcemonal@hotmail.com; Arslan, Gungor; Dolek, Yemliha; Efe, Esma

    2016-01-01

    The aim of this study is to evaluate the incidental testicular doses during prostate radiation therapy with intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc radiotherapy (VMAT) at different energies. Dosimetric data of 15 patients with intermediate-risk prostate cancer who were treated with radiotherapy were analyzed. The prescribed dose was 78 Gy in 39 fractions. Dosimetric analysis compared testicular doses generated by 7-field intensity-modulated radiotherapy and volumetric-modulated arc radiotherapy with a single arc at 6, 10, and 15 MV energy levels. Testicular doses calculated from the treatment planning system and doses measured from the detectors were analyzed. Mean testicular doses from the intensity-modulated radiotherapy and volumetric-modulated arc radiotherapy per fraction calculated in the treatment planning system were 16.3 ± 10.3 cGy vs 21.5 ± 11.2 cGy (p = 0.03) at 6 MV, 13.4 ± 10.4 cGy vs 17.8 ± 10.7 cGy (p = 0.04) at 10 MV, and 10.6 ± 8.5 cGy vs 14.5 ± 8.6 cGy (p = 0.03) at 15 MV, respectively. Mean scattered testicular doses in the phantom measurements were 99.5 ± 17.2 cGy, 118.7 ± 16.4 cGy, and 193.9 ± 14.5 cGy at 6, 10, and 15 MV, respectively, in the intensity-modulated radiotherapy plans. In the volumetric-modulated arc radiotherapy plans, corresponding testicular doses per course were 90.4 ± 16.3 cGy, 103.6 ± 16.4 cGy, and 139.3 ± 14.6 cGy at 6, 10, and 15 MV, respectively. In conclusions, this study was the first to measure the incidental testicular doses by intensity-modulated radiotherapy and volumetric-modulated arc radiotherapy plans at different energy levels during prostate-only irradiation. Higher photon energy and volumetric-modulated arc radiotherapy plans resulted in higher incidental testicular doses compared with lower photon energy and intensity-modulated radiotherapy plans.

  13. Radiation sensitivity and EPR dosimetric potential of gallic acid and its esters

    International Nuclear Information System (INIS)

    Tuner, Hasan; Oktay Bal, M.; Polat, Mustafa

    2015-01-01

    In the preset work the radiation sensitivities of Gallic Acid anhydrous and monohydrate, Octyl, Lauryl, and Ethyl Gallate (GA, GAm, OG, LG, and EG) were investigated in the intermediate (0.5–20 kGy) and low radiation (<10 Gy) dose range using Electron Paramagnetic Resonance (EPR) spectroscopy. While OG, LG, and EG are presented a singlet EPR spectra, their radiation sensitivity found to be very different in the intermediate dose range. At low radiation dose range (<10 Gy) only LG is found to be present a signal that easily distinguished from the noise signals. The intermediate and low dose range radiation sensitivities are compared using well known EPR dosimeter alanine. The radiation yields (G) of the interested material were found to be 1.34×10 −2 , 1.48×10 −2 , 4.14×10 −2 , and 6.03×10 −2 , 9.44×10 −2 for EG, GA, GAm, OG, and LG, respectively at the intermediate dose range. It is found that the simple EPR spectra and the noticeable EPR signal of LG make it a promising dosimetric material to be used below 10 Gy of radiation dose. - Highlights: • Radiation sensitivity of gallic acid and its esters were studied in intermediate and low radiation dose range using EPR. • While the irradiated samples of GA were presented complex EPR spectra the esters presented singlet ESR spectra. • Samples were compared to alanine in terms of the dosimetric point of view. • The radiation sensitivities of the investigated materials were very low at intermediate doses. • Lauryl ester of gallic acid was found to present a good sensitivity below 10 Gy

  14. Comparative Toxicity and Dosimetric Profile of Whole-Pelvis Versus Prostate Bed-Only Intensity-Modulated Radiation Therapy After Prostatectomy

    Energy Technology Data Exchange (ETDEWEB)

    Deville, Curtiland, E-mail: deville@uphs.upenn.edu [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Vapiwala, Neha [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Hwang, Wei-Ting [Department of Biostatistics and Epidemiology, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Lin Haibo; Bar Ad, Voichita; Tochner, Zelig; Both, Stefan [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania (United States)

    2012-03-15

    Purpose: To assess whether whole-pelvis (WP) intensity modulated radiation therapy (IMRT) for prostate cancer (PCa) after prostatectomy is associated with increased toxicity compared to prostate-bed only (PB) IMRT. Methods and Materials: All patients (n = 67) undergoing postprostatectomy IMRT to 70.2 Gy at our institution from January 2006 to January 2009 with minimum 12-month follow-up were divided into WP (n = 36) and PB (n = 31) comparison groups. WP patients received initial pelvic nodal IMRT to 45 Gy. Pretreatment demographics, bladder and rectal dose-volume histograms, and maximum genitourinary (GU) and gastrointestinal (GI) toxicities were compared. Logistic regression models evaluated uni- and multivariate associations between pretreatment demographics and toxicities. Results: Pretreatment demographics including age and comorbidities were similar between groups. WP patients had higher Gleason scores, T stages, and preoperative prostate-specific antigen (PSA) levels, and more WP patients underwent androgen deprivation therapy (ADT). WP minimum (Dmin) and mean bladder doses, bladder volumes receiving more than 5 Gy (V5) and V20, rectal Dmin, and PB bladder and rectal V65 were significantly increased. Maximum acute GI toxicity was Grade 2 and was increased for WP (61%) vs. PB (29%) patients (p = 0.001); there was no significant difference in acute Grade {>=}2 GU toxicity (22% WP vs. 10% PB; p = 0.193), late Grade {>=}2 GI toxicity (3% WP vs. 0% PB; p = 0.678), or late Grade {>=}2 GU toxicity (28% WP vs. 19% PB; p = 0.274) with 25-month median follow-up (range, 12-44 months). On multivariate analysis, long-term ADT use was associated with Grade {>=}2 late GU toxicity (p = 0.02). Conclusion: Despite dosimetric differences in irradiated bowel, bladder, and rectum, WP IMRT resulted only in clinically significant increased acute GI toxicity in comparison to that with PB IMRT, with no differences in GU or late GI toxicity.

  15. Qualitative dosimetric system for radiation processing. Technology for pilot scale preparation

    International Nuclear Information System (INIS)

    Moraru, R.

    1998-01-01

    Good manufacturing practice for radiation processing requires a very strictly tracking of the processed products. A method of labelling and identification of the irradiated and nonirradiated products is required. The qualitative dosimetric system provides a fast method for monitoring the product flow. Such dosimeters are attached on each product box, usually as labels, and offer a YES/NO information about the passing of products through the radiation field. Usually, this information consists in a change of colour. The qualitative dosimetric system that we realised is based on the degradation of polyvinylchloride (PVC) under radiation field. An amount of hydrochloric acid is released in this reaction. A pH indicator, included in the system, changes its colour at different absorbed dose. The changes of colour happened in a certain pH interval called turning range. We used as pH indicator the RED CONGO colorant with turning range of pH = 3 to 5 (from blue to red). A schematic view of the qualitative dosimeter is given. The initial colour is red and it continuously changes to brown, at 1 kGy absorbed dose, and to blue-green, for 5-100 kGy. The main features of this qualitative dosimetric system are: - Quick and easy to read information about product passing through radiation field; - Absorbed dose range, 1-300 kGy; - Independence of absorbed dose rate in the interval 5-100 kGy/h; - Stability, 3 year in the dark and 1 year in sun light; - Good reproducibility. The preparation technology consists in the following steps: 1. Preparation of the solutions: a) PVC in cyclohexanone solution b) RED CONGO in water solution; 2. Preparation of the system support consisting in dropping the PVC solution on adhesive labels; 3. Sample preparation consists in dropping the colorant solution on the system support; 4. Batch trial tests. The trial test was performed at IETI 10000 irradiation plant belonging to IFIN-HH and the reference absorbed dose was determined by Fricke dosimetry. The

  16. Dosimetric implications associated to heterogeneity dose correction in stereotactic body radiation therapy (SBRT) of lung cancer; Implicaciones dosimetricas asociadas al calculo de dosis con correccion de heterogeneidad en radioterapia estereotaxica extracraneal (SBRT) de pulmon

    Energy Technology Data Exchange (ETDEWEB)

    Zucca Aparicio, D.; Perez Moreno, J. M.; Fernandez Leton, P.; Garcia Ruiz-Zorrila

    2016-10-01

    Treatment of lung lesions using stereotactic body radiation therapy (SBRT) requires algorithms with corrections that adequately model the behavior of narrow beams in the presence of tissue heterogeneities, although protocols such as RTOG 0236 excluded these kind of corrections. 100 cases were evaluated retrospectively following the RTOG 0813 and RTOG 0915 guidelines, by obtaining the deviations of the relevant dosimetric indicators from Monte Carlo (MC) and Pencil Beam (PB), maintaining the same configuration and monitor units (MU). Deviations between MC and PB have been classified according to the volume and density of the lesion. The greatest variations (up to 45% difference in D50%) are found for cases with lower volume and density, where the lesion is almost equivalent to lung tissue, given the higher proportion of air surrounding the periphery of the tumor, and the reduction of the radiation fields, resulting in a lack of electronic equilibrium that must be properly considered in the treatment planning system. These deviations involve dosimetric implications which are observable in clinical outcomes, determining how to proceed in treatment planning, to ensure that the actual dose delivered is performed accordingly to the prescription dose, while requiring the use of algorithms with a proper heterogeneity correction. (Author)

  17. Dosimetric model for antibody targeted radionuclide therapy of tumor cells in cerebrospinal fluid

    International Nuclear Information System (INIS)

    Millar, W.T.; Barrett, A.

    1990-01-01

    Although encouraging results have been obtained using systemic radioimmunotherapy in the treatment of cancer, it is likely that regional applications may prove more effective. One such strategy is the treatment of central nervous system leukemia in children by intrathecal instillation of targeting or nontargeting beta particle emitting radionuclide carriers. The beta particle dosimetry of the spine is assessed, assuming that the spinal cord and the cerebrospinal fluid compartment can be adequately represented by a cylindrical annulus. The radionuclides investigated were 90 Y, 131 I, 67 Cu, and 199 Au. It is shown that the radiation dose to the cord can be significantly reduced using short range beta particle emitters and that there is little advantage in using targeting carriers with these radionuclides. 199 Au and 67 Cu also have the advantage of having a suitable gamma emission for imaging, permitting pretherapy imaging and dosimetric calculations to be undertaken prior to therapy. If these methods prove successful, it may be possible to replace the external beam component used in the treatment of central nervous system leukemia in children by intrathecal radionuclide therapy, thus reducing or avoiding side effects such as growth and intellectual impairment

  18. SU-E-P-40: Dosimetric Characteristics of Field Aperture Margin Design in Stereotactic Body Radiation Therapy (SBRT)

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, J

    2015-06-15

    Purpose: To characterize the dosimetric effects of field aperture margin design in Stereotactic Body Radiation Therapy (SBRT). Methods: Three artificial spherical PTVs, with diameter of 10mm, 20mm and 30mm, were created on CT images of a human body thoracic phantom. Seven non-coplanar isocentric fields were used for treatment planning. For each PTV, treatment plans with margins 0mm, 1mm, 2mm and 3mm were planned. Dosimetric comparison among plans was done considering the following parameters: prescribed isodose line for target coverage, maximum dose, mean dose as well as dose spillages of V80, V50, and V20. Results: Corresponding to aperture margins of 0mm, 1mm,2m and 3mm used in the treatment planning, the percentage of isodose line chosen for dose prescription increases from 65% to 93% for 10mm PTV, 70% to 92% for 20mm PTV, and 75% to 92% for 30mm PTV. The maximum dose decrease accordingly from 155.7% to 109.5% for 10mm PTV, 145% to 111.6% for 20mm PTV, 137% to 112.2% for 30mm PTV. The mean dose decrease from 138.% to 104.4% for 10mm PTV, 122.8% to 106.1% for 20mm PTV, 121.3% to 106% for 30mm PTV. Dose spillages (mm3) increase (V80−2.6 to 4.02, V50−4.55 to 9.3, V20–87.86 to 101.71) for 10 mm PTV, (V80−6.78 to 9.89, V50–13.46 to 20.4, V20-119.16 to 219.1) for 20 mm PTV, (V80–22.01 to 28.59, V50–41.56 to 52.66, V20-532.71 to 551.84) for 30 mm PTV. Conclusion: In SBRT treatment planning, tight field aperture margin requires prescribing dose to lower isodose line that leading to higher dose inhomogeneity and higher mean dose to PTV. Loose margin allows prescribing dose to higher isodose line, therefore improves the dose homogeneity. However, it increases dose spillages. Clinician could try different margins according to the PTV size and location of surrounding critical organs to optimize the dose delivered to the patient.

  19. Computed Tomography Appearance of Early Radiation Injury to the Lung: Correlation With Clinical and Dosimetric Factors

    International Nuclear Information System (INIS)

    Jenkins, Peter; Welsh, Anne

    2011-01-01

    Purpose: To systematically assess the spectrum of radiologic changes in the lung after radiation therapy for non-small-cell lung cancer. Methods and Materials: We reviewed the cases of 146 patients treated with radical radiotherapy at our institution. All patients had computed tomography (CT) scans performed 3 months after completion of therapy. Radiographic appearances were categorized using a standard grading system. The association of these abnormalities with pretreatment factors and clinical radiation pneumonitis (RP) was investigated. Results: New intrapulmonary abnormalities were seen in 92 patients (63%). These were ground-glass opacity in 16 (11%), patchy consolidation in 19 (13%), and diffuse consolidation in 57 (39%). Twenty-five patients (17%) developed clinical symptoms of RP. Although 80% of the patients with RP had areas of consolidation seen on the posttreatment CT scan, the majority (74%) of patients with such radiographic changes were asymptomatic. For patients with lung infiltrates, the minimum isodose encompassing the volume of radiologic abnormality was usually ≥27 Gy. Traditional dose-volume metrics, pulmonary function tests, and the coadministration of angiotensin converting enzyme inhibitors (ACE-I) were all strongly correlated with the presence of radiologic injury on univariate analysis (p ≤ 0.002). There was also an inverse correlation between prior smoking history and CT scan changes (p = 0.02). On multivariate analysis, dosimetric parameters and the use of ACE-I retained significance (p = 0.005). Conclusions: Our findings suggest that there is substantial interindividual variation in lung radiosensitivity. ACE-I prevented the radiologic changes seen after high-dose radiation therapy, and their role as radioprotectants warrants further investigation.

  20. Dosimetric effect of target expansion and setup uncertainty during radiation therapy in pediatric craniopharyngioma

    International Nuclear Information System (INIS)

    Beltran, Chris; Naik, Mihir; Merchant, Thomas E.

    2010-01-01

    Purpose: Investigate the effect of tumor change and setup uncertainties on target coverage for pediatric craniopharyngioma during RT. Methods and materials: Fifteen pediatric patients with craniopharyngioma (mean 5.1 years) were included in this study. MRI was performed before and a median of six times during RT to monitor changes in the tumor volume. IMRT plans were created and compared to the CRT plan used for treatment. The role of adaptive therapy based on GTV changes was investigated. Dosimetric effects of interfraction and intrafraction motion were examined. Results: The mean of the maximal change in the GTV was 28.5% [-20.7% to 82.0%]. For the standard margin IMRT plans, the mean D 95 of the base plan on the base target was 53.6 Gy [53.1-54.1]. The mean D 95 of the base plans on the adaptive targets was 52.1 Gy [47.9-54.1]. The D 95 for the adaptive plan on the adaptive target was 53.8 Gy [53.4-54.3]. A linear regression equation of y=-0.12x , r 2 = 0.70, was found for the percent change in D 95 of the PTV (y) vs. the percent change in the GTV (x). Inter and intrafraction motion did not affect the target coverage for standard and reduced margin plans. Conclusions: The GTV of pediatric craniopharyngioma patients change size during therapy and adaptive planning is critical for conformal plans; therefore early and regular surveillance imaging is required.

  1. Dosimetric system for prolonged manned flights

    International Nuclear Information System (INIS)

    Akatov, Yu.A.; Kovalev, E.E.; Sakovich, V.A.; Deme, Sh.; Fekher, I.; Nguen, V.D.

    1991-01-01

    Comments for the All-Union state standard 25645.202-83 named Radiation safety of a spacecraft crew during space flight. Requirements for personnel dosimetric control, are given. Devices for the dosimetric control used in manned space flights nowadays are reviewed. The performance principle and structure of the FEDOR dosimetric complex under development are discussed

  2. A dosimetric comparison of 3D conformal vs intensity modulated vs volumetric arc radiation therapy for muscle invasive bladder cancer

    International Nuclear Information System (INIS)

    Foroudi, Farshad; Kron, Tomas; Wilson, Lesley; Bressel, Mathias; Haworth, Annette; Hornby, Colin; Pham, Daniel; Cramb, Jim; Gill, Suki; Tai, Keen Hun

    2012-01-01

    To compare 3 Dimensional Conformal radiotherapy (3D-CRT) with Intensity Modulated Radiotherapy (IMRT) with Volumetric-Modulated Arc Therapy (VMAT) for bladder cancer. Radiotherapy plans for 15 patients with T2-T4N0M0 bladder cancer were prospectively developed for 3-DCRT, IMRT and VMAT using Varian Eclipse planning system. The same radiation therapist carried out all planning and the same clinical dosimetric constraints were used. 10 of the patients with well localised tumours had a simultaneous infield boost (SIB) of the primary tumour planned for both IMRT and VMAT. Tumour control probabilities and normal tissue complication probabilities were calculated. Mean planning time for 3D-CRT, IMRT and VMAT was 30.0, 49.3, and 141.0 minutes respectively. The mean PTV conformity (CI) index for 3D-CRT was 1.32, for IMRT 1.05, and for VMAT 1.05. The PTV Homogeneity (HI) index was 0.080 for 3D-CRT, 0.073 for IMRT and 0.086 for VMAT. Tumour control and normal tissue complication probabilities were similar for 3D-CRT, IMRT and VMAT. The mean monitor units were 267 (range 250–293) for 3D-CRT; 824 (range 641–1083) for IMRT; and 403 (range 333–489) for VMAT (P < 0.05). Average treatment delivery time were 2:25min (range 2:01–3:09) for 3D-CRT; 4:39 (range 3:41–6:40) for IMRT; and 1:14 (range 1:13–1:14) for VMAT. In selected patients, the SIB did not result in a higher dose to small bowel or rectum. VMAT is associated with similar dosimetric advantages as IMRT over 3D-CRT for muscle invasive bladder cancer. VMAT is associated with faster delivery times and less number of mean monitor units than IMRT. SIB is feasible in selected patients with localized tumours

  3. Dosimetric improvements following 3D planning of tangential breast irradiation

    International Nuclear Information System (INIS)

    Aref, Amr; Thornton, Dale; Youssef, Emad; He, Tony; Tekyi-Mensah, Samuel; Denton, Lori; Ezzell, Gary

    2000-01-01

    Purpose: To evaluate the dosimetric difference between a simple radiation therapy plan utilizing a single contour and a more complex three-dimensional (3D) plan utilizing multiple contours, lung inhomogeneity correction, and dose-based compensators. Methods and Materials: This is a study of the radiation therapy (RT) plans of 85 patients with early breast cancer. All patients were considered for breast-conserving management and treated by conventional tangential fields technique. Two plans were generated for each patient. The first RT plan was based on a single contour taken at the central axis and utilized two wedges. The second RT plan was generated by using the 3D planning system to design dose-based compensators after lung inhomogeneity correction had been made. The endpoints of the study were the comparison between the volumes receiving greater than 105% and greater than 110% of the reference dose, as well as the magnitude of the treated volume maximum dose. Dosimetric improvement was defined to be of significant value if the volume receiving > 105% of one plan was reduced by at least 50% with the absolute difference between the volumes being 5% or greater. The dosimetric improvements in 49 3D plans (58%) were considered of significant value. Patients' field separation and breast size did not predict the magnitude of improvement in dosimetry. Conclusion: Dose-based compensator plans significantly reduced the volumes receiving > 105%, >110%, and volume maximum dose.

  4. Utilization of a photon transport code to investigate radiation therapy treatment planning quantities and techniques

    International Nuclear Information System (INIS)

    Palta, J.R.

    1981-01-01

    A versatile computer program MORSE, based on neutron and photon transport theory has been utilzed to investigate radiation therapy treatment planning quantities and techniques. A multi-energy group representation of transport equation provides a concise approach in utilizing Monte Carlo numerical techniques to multiple radiation therapy treatment planning problems. Central axis total and scattered dose distributions for homogeneous and inhomogeneous water phantoms are calculated and the correction factor for lung and bone inhomogeneities are also evaluated. Results show that Monte Carlo calculations based on multi-energy group tansport theory predict the depth dose distributions that are in good agreement with available experimental data. Central axis depth dose distributions for a bremsstrahlung spectrum from a linear accelerator is also calculated to exhibit the versatility of the computer program in handling multiple radiation therapy problems. A novel approach is undertaken to study the dosimetric properties of brachytherapy sources

  5. Dosimetric properties of an amorphous silicon electronic portal imaging device for verification of dynamic intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Greer, Peter B.; Popescu, Carmen C.

    2003-01-01

    Dosimetric properties of an amorphous silicon electronic portal imaging device (EPID) for verification of dynamic intensity modulated radiation therapy (IMRT) delivery were investigated. The EPID was utilized with continuous frame-averaging during the beam delivery. Properties studied included effect of buildup, dose linearity, field size response, sampling of rapid multileaf collimator (MLC) leaf speeds, response to dose-rate fluctuations, memory effect, and reproducibility. The dependence of response on EPID calibration and a dead time in image frame acquisition occurring every 64 frames were measured. EPID measurements were also compared to ion chamber and film for open and wedged static fields and IMRT fields. The EPID was linear with dose and dose rate, and response to MLC leaf speeds up to 2.5 cm s-1 was found to be linear. A field size dependent response of up to 5% relative to d max ion-chamber measurement was found. Reproducibility was within 0.8% (1 standard deviation) for an IMRT delivery recorded at intervals over a period of one month. The dead time in frame acquisition resulted in errors in the EPID that increased with leaf speed and were over 20% for a 1 cm leaf gap moving at 1.0 cm s-1. The EPID measurements were also found to depend on the input beam profile utilized for EPID flood-field calibration. The EPID shows promise as a device for verification of IMRT, the major limitation currently being due to dead-time in frame acquisition

  6. Dosimetric commissioning and system for stereotactic radiation treatments based on linear accelerators with dynamic micromultilaminas collimators

    International Nuclear Information System (INIS)

    Ascension, Yudy; Alfonso, Rodolfo; Silvestre, Ileana

    2009-01-01

    Once installed and accepted, a system for stereotactic radiosurgery / stereotactic radiotherapy (CERs / RTE) requires, before starting to be used clinically in patients undergoing a process of commissioning dosimetry, which evaluates all geometric parameters, physical, Dosimetric and technical impact on the precision and accuracy of treatment to administer, and therefore its effectiveness. This process includes training and familiarization of the multidisciplinary team (medical physicists, radiation oncologists, neurosurgeons, dosimetrists, biomedical engineers) with the equipment and techniques used, the quality assurance program and special radiation protection standards for this technology. The aim of this work is to prepare the pre-clinical dosimetric conditions to ensure the quality and radiation safety of treatment with CER RTE. Treatment with CER RTE INOR has a linear accelerator equipped with a micro-multileaf collimator dynamic tertiary (dMLC 3Dline). The system aceleradordMLC geometric and dosimetric was calibrated, using ionization chambers miniature, diode and film dosimetry. The immobilization of the patient and location of the lesion is made by both invasive stereotactic frames and relocatable. The computerized planning of the CER / TEN is done with the ERGO system, for which commissioning is designed test cases of increasing complexity, using planes and anthropomorphic dummies, which help assess the accuracy of the dosimetric calculations and accuracy of the system as a whole. We compared the results of the planning system with measurements, showing that the discrepancies are within tolerances, so it is concluded that from the standpoint of physical dosimetry, the system-under-ERGO accelerator MLC is eligible for clinical use. (author)

  7. Definition of the supraclavicular and infraclavicular nodes: implications for three-dimensional CT-based conformal radiation therapy.

    Science.gov (United States)

    Madu, C N; Quint, D J; Normolle, D P; Marsh, R B; Wang, E Y; Pierce, L J

    2001-11-01

    To delineate with computed tomography (CT) the anatomic regions containing the supraclavicular (SCV) and infraclavicular (IFV) nodal groups, to define the course of the brachial plexus, to estimate the actual radiation dose received by these regions in a series of patients treated in the traditional manner, and to compare these doses to those received with an optimized dosimetric technique. Twenty patients underwent contrast material-enhanced CT for the purpose of radiation therapy planning. CT scans were used to study the location of the SCV and IFV nodal regions by using outlining of readily identifiable anatomic structures that define the nodal groups. The brachial plexus was also outlined by using similar methods. Radiation therapy doses to the SCV and IFV were then estimated by using traditional dose calculations and optimized planning. A repeated measures analysis of covariance was used to compare the SCV and IFV depths and to compare the doses achieved with the traditional and optimized methods. Coverage by the 90% isodose surface was significantly decreased with traditional planning versus conformal planning as the depth to the SCV nodes increased (P correlation was found between brachial plexus depth and SCV depth up to 7 cm. Conformal optimized planning provided improved dosimetric coverage compared with standard techniques.

  8. Helical Tomotherapy-Based STAT Stereotactic Body Radiation Therapy: Dosimetric Evaluation for a Real-Time SBRT Treatment Planning and Delivery Program

    International Nuclear Information System (INIS)

    Dunlap, Neal; McIntosh, Alyson; Sheng Ke; Yang Wensha; Turner, Benton; Shoushtari, Asal; Sheehan, Jason; Jones, David R.; Lu Weigo; Ruchala, Keneth; Olivera, Gustavo; Parnell, Donald; Larner, James L.; Benedict, Stanley H.; Read, Paul W.

    2010-01-01

    Stereotactic body radiation therapy (SBRT) treatments have high-dose gradients and even slight patient misalignment from the simulation to treatment could lead to target underdosing or organ at risk (OAR) overdosing. Daily real-time SBRT treatment planning could minimize the risk of geographic miss. As an initial step toward determining the clinical feasibility of developing real-time SBRT treatment planning, we determined the calculation time of helical TomoTherapy-based STAT radiation therapy (RT) treatment plans for simple liver, lung, and spine SBRT treatments to assess whether the planning process was fast enough for practical clinical implementation. Representative SBRT planning target volumes for hypothetical liver, peripheral lung, and thoracic spine lesions and adjacent OARs were contoured onto a planning computed tomography scan (CT) of an anthropomorphic phantom. Treatment plans were generated using both STAT RT 'full scatter' and conventional helical TomoTherapy 'beamlet' algorithms. Optimized plans were compared with respect to conformality index (CI), heterogeneity index (HI), and maximum dose to regional OARs to determine clinical equivalence and the number of required STAT RT optimization iterations and calculation times were determined. The liver and lung dosimetry for the STAT RT and standard planning algorithms were clinically and statistically equivalent. For the liver lesions, 'full scatter' and 'beamlet' algorithms showed a CI of 1.04 and 1.04 and HI of 1.03 and 1.03, respectively. For the lung lesions, 'full scatter' and 'beamlet' algorithms showed a CI of 1.05 and 1.03 and HI of 1.05and 1.05, respectively. For spine lesions, 'full scatter' and 'beamlet' algorithms showed a CI of 1.15 and 1.14 and HI of 1.22 and 1.14, respectively. There was no difference between treatment algorithms with respect to maximum doses to the OARs. The STAT RT iteration time with current treatment planning systems is 45 sec, and the treatment planning required 3

  9. Treatment planning study comparing proton therapy, RapidArc and intensity modulated radiation therapy for a synchronous bilateral lung cancer case

    Directory of Open Access Journals (Sweden)

    Suresh Rana

    2014-03-01

    Full Text Available Purpose: The main purpose of this study is to perform a treatment planning study on a synchronous bilateral non-small cell lung cancer case using three treatment modalities: uniform scanning proton therapy, RapidArc, and intensity modulated radiation therapy (IMRT. Methods: The maximum intensity projection (MIP images obtained from the 4 dimensional-computed tomography (4DCT scans were used for delineation of tumor volumes in the left and right lungs. The average 4D-CT was used for the treatment planning among all three modalities with identical patient contouring and treatment planning goal. A proton therapy plan was generated in XiO treatment planning system (TPS using 2 fields for each target. For a comparative purpose, IMRT and RapidArc plans were generated in Eclipse TPS. Treatment plans were generated for a total dose of 74 CGE or Gy prescribed to each planning target volume (PTV (left and right with 2 CGE or Gy per fraction. In IMRT and RapidArc plans, normalization was done based on PTV coverage values in proton plans. Results: The mean PTV dose deviation from the prescription dose was lower in proton plan (within 3.4%, but higher in IMRT (6.5% to 11.3% and RapidArc (3.8% to 11.5% plans. Proton therapy produced lower mean dose to the total lung, heart, and esophagus when compared to IMRT and RapidArc. The relative volume of the total lung receiving 20, 10, and 5 CGE or Gy (V20, V10, and V5, respectively were lower using proton therapy than using IMRT, with absolute differences of 9.71%, 22.88%, and 39.04%, respectively. The absolute differences in the V20, V10, and V5 between proton and RapidArc plans were 4.84%, 19.16%, and 36.8%, respectively, with proton therapy producing lower dosimetric values. Conclusion: Based on the results presented in this case study, uniform scanning proton therapy has a dosimetric advantage over both IMRT and RapidArc for a synchronous bi-lateral NSCLC, especially for the normal lung tissue, heart, and

  10. Volumetric modulated arc therapy versus step-and-shoot intensity modulated radiation therapy in the treatment of large nerve perineural spread to the skull base: a comparative dosimetric planning study

    Energy Technology Data Exchange (ETDEWEB)

    Gorayski, Peter; Fitzgerald, Rhys; Barry, Tamara [Department of Radiation Oncology, Princess Alexandra Hospital, Woolloongabba, Queensland (Australia); Burmeister, Elizabeth [Nursing Practice Development Unit, Princess Alexandra Hospital and Research Centre for Clinical and Community Practice Innovation, Griffith University, Brisbane, Queensland (Australia); Foote, Matthew [Department of Radiation Oncology, Princess Alexandra Hospital, Woolloongabba, Queensland (Australia); Diamantina Institute, University of Queensland, Brisbane, Queensland (Australia)

    2014-06-15

    Cutaneous squamous cell carcinoma with large nerve perineural (LNPN) infiltration of the base of skull is a radiotherapeutic challenge given the complex target volumes to nearby organs at risk (OAR). A comparative planning study was undertaken to evaluate dosimetric differences between volumetric modulated arc therapy (VMAT) versus intensity modulated radiation therapy (IMRT) in the treatment of LNPN. Five consecutive patients previously treated with IMRT for LNPN were selected. VMAT plans were generated for each case using the same planning target volumes (PTV), dose prescriptions and OAR constraints as IMRT. Comparative parameters used to assess target volume coverage, conformity and homogeneity included V95 of the PTV (volume encompassed by the 95% isodose), conformity index (CI) and homogeneity index (HI). In addition, OAR maximum point doses, V20, V30, non-target tissue (NTT) point max doses, NTT volume above reference dose, monitor units (MU) were compared. IMRT and VMAT plans generated were comparable for CI (P = 0.12) and HI (P = 0.89). VMAT plans achieved better V95 (P = < 0.001) and reduced V20 and V30 by 652 cubic centimetres (cc) (28.5%) and 425.7 cc (29.1%), respectively. VMAT increased MU delivered by 18% without a corresponding increase in NTT dose. Compared with IMRT plans for LNPN, VMAT achieved comparable HI and CI.

  11. A Combined Tissue Kinetics and Dosimetric Model of Respiratory Tissue Exposed to Radiation

    Energy Technology Data Exchange (ETDEWEB)

    John R. Ford

    2005-11-01

    Existing dosimetric models of the radiation response of tissues are essentially static. Consideration of changes in the cell populations over time has not been addressed realistically. For a single acute dose this is not a concern, but for modeling chronic exposures or fractionated acute exposures, the natural turnover and progression of cells could have a significant impact on a variety of endpoints. This proposal addresses the shortcomings of current methods by combining current dose-based calculation techniques with information on the cell turnover for a model tissue. The proposed model will examine effects at the single-cell level for an exposure of a section of human bronchiole. The cell model will be combined with Monte Carlo calculations of doses to cells and cell nuclei due to varying dose-rates of different radiation qualities. Predictions from the model of effects on survival, apoptosis rates, and changes in the number of cycling and differentiating cells will be tested experimentally. The availability of dynamic dosimetric models of tissues at the single-cell level will be useful for analysis of low-level radiation exposures and in the development of new radiotherapy protocols.

  12. SU-F-T-649: Dosimetric Evaluation of Non-Coplanar Arc Therapy Using a Novel Rotating Gamma Ray System

    Energy Technology Data Exchange (ETDEWEB)

    Eldib, A; Chibani, O; Jin, L; Fan, J; Veltchev, I; Ma, C [Fox Chase Cancer Center, Philadelphia, PA (United States); Mora, G [Universidade de Lisboa, Codex, Lisboa (Portugal); Li, J [Cyber Medical Inc, Xian, Shaanxi (China)

    2016-06-15

    Purpose: Stereotactic intra and extra-cranial body radiation therapy has evolved with advances in treatment accuracy, effective radiation dose, and parameters necessary to maximize machine capabilities. Novel gamma systems with a ring type gantry were developed having the ability to perform oblique arcs. The aim of this study is to explore the dosimetric advantages of this new system. Methods: The rotating Gamma system is named CybeRay (Cyber Medical Corp., Xian, China). It has a treatment head of 16 cobalt-60 sources focused to the isocenter, which can rotate 360° on the ring gantry and swing 35° in the superior direction. Treatment plans were generated utilizing our in-house Monte Carlo treatment planning system. A cylindrical phantom was modeled with 2mm voxel size. Dose inside the cylindrical phantom was calculated for coplanar and non-coplanar arcs. Dosimetric differences between CybeRay cobalt beams and CyberKnife 6MV beams were compared in a lung phantom and for previously treated SBRT patients. Results: The full width at half maxima of cross profiles in the S-I direction for the coplanar setup matched the cone sizes, while for the non-coplanar setup, FWHM was larger by 2mm for a 10mm cone and about 5mm for larger cones. In the coronal and sagittal view, coplanar beams showed elliptical shaped isodose lines, while non-coplanar beams showed circular isodose lines. Thus proper selection of the oblique angle and cone size can aid optimal dose matching to the target volume. Comparing a single 5mm cone from CybeRay to that from CyberKnife showed similar penumbra in a lung phantom but CybeRay had significant lower doses beyond lung tissues. Comparable treatment plans were obtained with CybeRay as that from CyberKnife.ConclusionThe noncoplanar multiple source arrangement of CybeRay will be of great clinical benefits for stereotactic intra and extra-cranial radiation therapy.

  13. Dosimetric comparison of volumetric modulated arc therapy (VMAT), DMlC (Dynamic IMRT), and 3DCRT in left breast cancer after breast conserving surgery receiving left breast irradiation

    International Nuclear Information System (INIS)

    Pratibha, Bauskar; Vibhay, Pareek; Rajendra, Bhalavat; Chandra, Manish

    2016-01-01

    Previous studies have demonstrated that the risk of ischemic heart disease is increased as a result of exposure to ionizing radiation in women treated for breast cancer. Alternative radiation techniques, such as dynamic intensity-modulated radiation therapy (DMLC), volumetric-modulated arc therapy (VMAT), have been shown to improve dosimetric parameters of the heart and substructures. However, these techniques have not been compared with each other to potentially guide treatment decisions. Volumetric modulated arc therapy (VMAT) is a novel extension of conventional intensity-modulated radiotherapy (c-IMRT), in which an optimized three dimensional dose distribution may be delivered in a single gantry rotation. VMAT is the predecessor to Rapid-Arc (Varian Medical System). This study uses VMAT, DMLC and 3DCRT to compare target volume coverage and doses to organs at risk (OARs), especially lung and heart doses, using these three techniques in whole breast irradiation after breast conserving surgery in left breast cancer cases

  14. Dosimetric methodology for extremities of individuals occupationally exposed to beta radiation using the optically stimulated luminescence technique

    International Nuclear Information System (INIS)

    Pinto, Teresa Cristina Nathan Outeiro

    2010-01-01

    A dosimetric methodology was established for the determination of extremity doses of individuals occupationally exposed to beta radiation, using Al 2 O 3 :C detectors and the optically stimulated luminescence (OSL) reader system microStar, Landauer. The main parts of the work were: characterization of the dosimetric material Al 2 O 3 :C using the OSL technique; establishment of the dose evaluation methodology; dose rate determination of beta radiation sources; application of the established method in a practical test with individuals occupationally exposed to beta radiation during a calibration simulation of clinical applicators; validation of the methodology by the comparison between the dose results of the practical test using the OSL and the thermoluminescence (TL) techniques. The results show that both the OSL Al-2O 3 :C detectors and the technique may be utilized for individual monitoring of extremities and beta radiation. (author)

  15. Dosimetric characterization of BeO samples in alpha, beta and X radiation beams using luminescent techniques

    International Nuclear Information System (INIS)

    Groppo, Daniela Piai

    2013-01-01

    In the medical field, the ionizing radiation is used both for therapeutic and diagnostic purposes, in a wide range of radiation doses. In order to ensure that the objective is achieved in practice, detailed studies of detectors and devices in different types of radiations beams are necessary. In this work a dosimetric characterization of BeO samples was performed using the techniques of thermoluminescence (TL) and optically stimulated luminescence (OSL) by a comparison of their response for alpha, beta and X radiations and the establishment of an appropriated system for use in monitoring of these radiations beams. The main results are: the high sensitivity to beta radiation for both techniques, good reproducibility of TL and OSL response (coefficients of variation lower than 5%), maximum energy dependence of the X radiation of 28% for the TL technique, and only 7% for the OSL technique, within the studied energy range. The dosimetric characteristics obtained in this work show the possibility of applying BeO samples to dosimetry of alpha, beta and X radiations, considering the studied dose ranges, using the TL and OSL techniques. From the results obtained, the samples of BeO showed their potential use for beam dosimetry in diagnostic radiology and radiotherapy. (author)

  16. Three-dimensional printer-aided casting of soft, custom silicone boluses (SCSBs) for head and neck radiation therapy.

    Science.gov (United States)

    Chiu, Tsuicheng; Tan, Jun; Brenner, Mathew; Gu, Xuejun; Yang, Ming; Westover, Kenneth; Strom, Tobin; Sher, David; Jiang, Steve; Zhao, Bo

    Custom tissue compensators provide dosimetric advantages for treating superficial or complex anatomy, but currently available fabrication technology is expensive or impractical for most clinical operations and yields compensators that are difficult for patients to tolerate. We aimed to develop an inexpensive, clinically feasible workflow for generating patient-specific, soft, custom silicone boluses (SCSBs) for head-and-neck (HN) radiation therapy. We developed a method using 3-dimensional printed parts for generating SCSBs for the treatment of HN cancers. The clinical workflow for generation of SCSBs was characterized inclusive of patient simulation to treatment in terms of resource time and cost. Dosimetric properties such as percentage depth dose and dose profiles were measured for SCSBs using GaF films. Comprehensive measurements were also conducted on an HN phantom. SCSBs were generated and used for electron or photon based radiation treatments of 7 HN patients with lesions at nose, cheek, eye, or ears. In vivo dose measurements with optically simulated luminescence dosimeters were performed. Total design and fabrication time from patient simulation to radiation treatment start required approximately 1 week, with fabrication constituting 1 to 2 working days depending on bolus surface area, volume, and complexity. Computed tomography and dosimetric properties of the soft bolus were similar to water. In vivo dose measurements on 7 treated patients confirmed that the dose deposition conformed to planned doses. Material costs were lower than currently available hard plastic boluses generated with 3-dimensional printing technology. All treated patients tolerated SCSBs for the duration of therapy. Generation and use of SCSBs for clinical use is feasible and effective for the treatment of HN cancers. Copyright © 2017 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  17. Safety and Efficacy of Stereotactic Ablative Radiation Therapy for Renal Cell Carcinoma Extracranial Metastases

    International Nuclear Information System (INIS)

    Wang, Chiachien Jake; Christie, Alana; Lin, Mu-Han; Jung, Matthew; Weix, Derek; Huelsmann, Lorel; Kuhn, Kristin; Meyer, Jeffrey; Desai, Neil; Kim, D. W. Nathan; Pedrosa, Ivan; Margulis, Vitaly; Cadeddu, Jeffrey; Sagalowsky, Arthur; Gahan, Jeffrey; Laine, Aaron; Xie, Xian-Jin; Choy, Hak; Brugarolas, James; Timmerman, Robert

    2017-01-01

    Purpose: Renal cell carcinoma is refractory to conventional radiation therapy but responds to higher doses per fraction. However, the dosimetric data and clinical factors affecting local control (LC) are largely unknown. We aimed to evaluate the safety and efficacy of stereotactic ablative radiation therapy (SAbR) for extracranial renal cell carcinoma metastases. Methods and Materials: We reviewed 175 metastatic lesions from 84 patients treated with SAbR between 2005 and 2015. LC and toxicity after SAbR were assessed with Response Evaluation Criteria in Solid Tumors (RECIST) version 1.1 and Common Terminology Criteria for Adverse Events (CTCAE) version 4.0. Predictors of local failure were analyzed with χ 2 , Kaplan-Meier, and log-rank tests. Results: In most cases (74%), SAbR was delivered with total doses of 40 to 60 Gy, 30 to 54 Gy, and 20 to 40 Gy in 5 fractions, 3 fractions, and a single fraction, respectively. The median biologically effective dose (BED) using the universal survival model was 134.5 Gy. The 1-year LC rate after SAbR was 91.2% (95% confidence interval, 84.9%-95.0%; median follow-up, 16.7 months). Local failures were associated with prior radiation therapy (hazard ratio [HR], 10.49; P<.0001), palliative-intent radiation therapy (HR, 4.63; P=.0189), spinal location (HR, 5.36; P=.0041), previous systemic therapy status (0-1 vs >1; HR, 3.52; P=.0217), and BED <115 Gy (HR, 3.45; P=.0254). Dose received by 99% of the target volume was the strongest dosimetric predictor for LC. Upon multivariate analysis, dose received by 99% of the target volume greater than BED of 98.7 Gy and systemic therapy status remained significant (HR, 0.12 and 3.64, with P=.0014 and P=.0472, respectively). Acute and late grade 3 toxicities attributed to SAbR were observed in 3 patients (1.7%) and 5 patients (2.9%), respectively. Conclusions: SAbR demonstrated excellent LC of metastatic renal cell carcinoma with a favorable safety profile when an adequate dose and

  18. Safety and Efficacy of Stereotactic Ablative Radiation Therapy for Renal Cell Carcinoma Extracranial Metastases

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Chiachien Jake [Kidney Cancer Program, Simmons Comprehensive Cancer Center, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Christie, Alana [Kidney Cancer Program, Simmons Comprehensive Cancer Center, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Lin, Mu-Han; Jung, Matthew; Weix, Derek; Huelsmann, Lorel; Kuhn, Kristin; Meyer, Jeffrey; Desai, Neil; Kim, D. W. Nathan [Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Pedrosa, Ivan [Department of Radiology, Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Margulis, Vitaly; Cadeddu, Jeffrey; Sagalowsky, Arthur; Gahan, Jeffrey [Department of Urology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Laine, Aaron [Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Xie, Xian-Jin [Kidney Cancer Program, Simmons Comprehensive Cancer Center, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Choy, Hak [Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Brugarolas, James [Kidney Cancer Program, Simmons Comprehensive Cancer Center, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Division of Hematology/Oncology, Department of Internal Medicine, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Timmerman, Robert [Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); and others

    2017-05-01

    Purpose: Renal cell carcinoma is refractory to conventional radiation therapy but responds to higher doses per fraction. However, the dosimetric data and clinical factors affecting local control (LC) are largely unknown. We aimed to evaluate the safety and efficacy of stereotactic ablative radiation therapy (SAbR) for extracranial renal cell carcinoma metastases. Methods and Materials: We reviewed 175 metastatic lesions from 84 patients treated with SAbR between 2005 and 2015. LC and toxicity after SAbR were assessed with Response Evaluation Criteria in Solid Tumors (RECIST) version 1.1 and Common Terminology Criteria for Adverse Events (CTCAE) version 4.0. Predictors of local failure were analyzed with χ{sup 2}, Kaplan-Meier, and log-rank tests. Results: In most cases (74%), SAbR was delivered with total doses of 40 to 60 Gy, 30 to 54 Gy, and 20 to 40 Gy in 5 fractions, 3 fractions, and a single fraction, respectively. The median biologically effective dose (BED) using the universal survival model was 134.5 Gy. The 1-year LC rate after SAbR was 91.2% (95% confidence interval, 84.9%-95.0%; median follow-up, 16.7 months). Local failures were associated with prior radiation therapy (hazard ratio [HR], 10.49; P<.0001), palliative-intent radiation therapy (HR, 4.63; P=.0189), spinal location (HR, 5.36; P=.0041), previous systemic therapy status (0-1 vs >1; HR, 3.52; P=.0217), and BED <115 Gy (HR, 3.45; P=.0254). Dose received by 99% of the target volume was the strongest dosimetric predictor for LC. Upon multivariate analysis, dose received by 99% of the target volume greater than BED of 98.7 Gy and systemic therapy status remained significant (HR, 0.12 and 3.64, with P=.0014 and P=.0472, respectively). Acute and late grade 3 toxicities attributed to SAbR were observed in 3 patients (1.7%) and 5 patients (2.9%), respectively. Conclusions: SAbR demonstrated excellent LC of metastatic renal cell carcinoma with a favorable safety profile when an adequate dose

  19. Development and application of a dosimetric methodology of therapeutic X radiation beams using a tandem system

    International Nuclear Information System (INIS)

    Sartoris, Carla Eri

    2001-01-01

    In radiotherapy the use of orthovoltage X radiation beams is still recommended; to obtain satisfactory results, a periodic control is necessary to check the performance of the ionization chambers and the radiation beams characteristics. This control is performed by using standard dosimetric procedures, as for example the determination of half-value layers and the absorbed dose rates. A Tandem system was established in this work using a pair of ionization chambers (a thimble type and a superficial type) used for measures in a medical institution, in substitution to the routine conventional procedure of determination of half-value layers using absorbers. The results obtained show the application of this method in dosimetric procedures of orthovoltage beams (radiotherapy) as a complement for a quality control program. (author)

  20. Therapy with 90Y microspheres: radiation protection in new medical therapies

    International Nuclear Information System (INIS)

    Rojo, Ana; Puerta, Nancy

    2013-01-01

    Primary liver cancer is one of the most frequent in the world and with a low cure rate. Radioembolization using 90y spheres is a promising treatment of this pathology and involves the percutaneous vascular application of radioisotope-labeled the order of Micron size particles. The advantages of this technique include the permit administered high doses of radiation to small volumes with low relative toxicity, offer the possibility of treating all the liver including microscopic tumors, and finally, the feasibility of combined with other therapies. Radiation protection in new medical therapies requires justification and optimization, as requirements for their implementation. The application of the principle of optimization in the context of the protection of the patient must be the minimum that it can be reasonably reached compatible with the required doses of treatment dose to healthy tissue. With 90 Y microspheres therapy this optimization applies to the activity of 90y which is administered to the patient, and estimation methods are postulated. in this work are analyzed comparatively these methods, described the early physicists, equations and the limitations of each. Finally, it is concluded that the optimal method to be implemented for the evaluation of the activity of 90 Y manage must be based in a voxel dosimetric model specific for each patient, however, the partitional method may be a good alternative if you don't have the tools to apply the method

  1. Prospective assessment of dosimetric/physiologic-based models for predicting radiation pneumonitis

    International Nuclear Information System (INIS)

    Kocak, Zafer; Borst, Gerben R.; Zeng Jing; Zhou Sumin; Hollis, Donna R.; Zhang Junan; Evans, Elizabeth S.; Folz, Rodney J.; Wong, Terrence; Kahn, Daniel; Belderbos, Jose S.A.; Lebesque, Joos V.; Marks, Lawrence B.

    2007-01-01

    Purpose: Clinical and 3D dosimetric parameters are associated with symptomatic radiation pneumonitis rates in retrospective studies. Such parameters include: mean lung dose (MLD), radiation (RT) dose to perfused lung (via SPECT), and pre-RT lung function. Based on prior publications, we defined pre-RT criteria hypothesized to be predictive for later development of pneumonitis. We herein prospectively test the predictive abilities of these dosimetric/functional parameters on 2 cohorts of patients from Duke and Netherlands Cancer Institute (NKI). Methods and Materials: For the Duke cohort, 55 eligible patients treated between 1999 and 2005 on a prospective IRB-approved study to monitor RT-induced lung injury were analyzed. A similar group of patients treated at the NKI between 1996 and 2002 were identified. Patients believed to be at high and low risk for pneumonitis were defined based on: (1) MLD; (2) OpRP (sum of predicted perfusion reduction based on regional dose-response curve); and (3) pre-RT DLCO. All doses reflected tissue density heterogeneity. The rates of grade ≥2 pneumonitis in the 'presumed' high and low risk groups were compared using Fisher's exact test. Results: In the Duke group, pneumonitis rates in patients prospectively deemed to be at 'high' vs. 'low' risk are 7 of 20 and 9 of 35, respectively; p = 0.33 one-tailed Fisher's. Similarly, comparable rates for the NKI group are 4 of 21 and 6 of 44, respectively, p = 0.41 one-tailed Fisher's. Conclusion: The prospective model appears unable to accurately segregate patients into high vs. low risk groups. However, considered retrospectively, these data are consistent with prior studies suggesting that dosimetric (e.g., MLD) and functional (e.g., PFTs or SPECT) parameters are predictive for RT-induced pneumonitis. Additional work is needed to better identify, and prospectively assess, predictors of RT-induced lung injury

  2. Dosimetric characterization of chemical-vapor-deposited diamond film irradiated with UV and beta radiation

    Science.gov (United States)

    Meléndrez, R.; Chernov, V.; Pedroza-Montero, M.; Barboza-Flores, M.

    2003-03-01

    Diamond is an excellent prospect for clinical radiation dosimetry due to its tissue-equivalence properties and being chemically inert. The use of diamond in radiation dosimetry has been halted by the high market price; although recently the capability of growing high quality polycrystalline has renewed the interest in using diamond films as detectors and dosimeters. In the present work we have characterized the dosimetric properties of diamond films synthesized by using chemical vapor deposition. The thermoluminescence (TL) of UV and beta exposed samples shows a glow curve composed of at least four peaks; one located around 587 K presents excellent TL properties suitable for dosimetric applications with ionizing and non ionizing radiation. The TL excitation spectrum exhibits maximum TL efficiency at 220 nm. The samples show regions of linear as well as supralinear behavior as a function or irradiation dose. The linear dose dependence was found for up to sixteen minutes of UV irradiation and 300 Gy for beta irradiated samples. The activation energy and the frequency factor were determined and found in the range of 0.32 - 0.89 eV and 1.1x10^2 - 2x10^8s_-1, respectively. The observed TL performance is reasonable appropriate to justify further investigation of diamond films as radiation dosimeters.

  3. Historical accounts of the radiation protection- Dosimetric surveillance of L. Berard Center personnel from 1960 to 1988

    International Nuclear Information System (INIS)

    Paoletti, H.

    1990-09-01

    In this thesis, the author describes the discovery of radiations, their first medical applications and first accidents that have been in the beginning of radiation protection and of its development. The author explains how the dosimetric monitoring has been organized at L. Berard Centre in Lyon (France)

  4. Current perspectives of radiation therapy. History of radiation therapy

    International Nuclear Information System (INIS)

    Itami, Jun

    2011-01-01

    More than 100 years have passed since the discovery of X-Strahlen by Roentgen. The history of radiation therapy has evolved under mutual stimulating relationships of the external beam radiation therapy by X-ray tubes and accelerators, and the internal radiation therapy employing radium and other radionuclides. The currently employed technologies in radiation therapy have its origin already till nineteen sixties and the development of physics and engineering have realized the original concept. (author)

  5. Dosimetric evaluation of indigenously developed non-lead bilayered radiation protective aprons

    International Nuclear Information System (INIS)

    Senthilkumar, S.

    2018-01-01

    Radiation shielding garments are commonly used to protect medical patients and radiation workers from X-radiation exposure during diagnostic imaging in hospitals. Originally, protective aprons consisted of lead-impregnated vinyl with a shielding equivalent given in millimeters of lead. All contained up to 2 mm of lead. While lead has long been used to shield patients from X-rays, its toxicity poses a health threat if the protective apron containing the metal wear out or the lead gets damaged. However, lead garments must be treated as hazardous waste for disposal and are heavy, causing back strain and other orthopedic problems for those who must wear them for long periods of time. The main purpose of this work was to indigenously develop light weight non lead based bilayered radiation protective aprons and evaluate dosimetrically with different combination of fabricated non lead materials and commercially available lead based aprons

  6. Intraoperative electron beam radiation therapy: technique, dosimetry, and dose specification: report of task force 48 of the radiation therapy committee, American association of physicists in medicine

    International Nuclear Information System (INIS)

    Palta, Jatinder R.; Biggs, Peter J.; Hazle, John D.; Huq, M. Saiful; Dahl, Robert A.; Ochran, Timothy G.; Soen, Jerry; Dobelbower, Ralph R.; McCullough, Edwin C.

    1995-01-01

    Intraoperative radiation therapy (IORT) is a treatment modality whereby a large single dose of radiation is delivered to a surgically open, exposed cancer site. Typically, a beam of megavoltage electrons is directed at an exposed tumor or tumor bed through a specially designed applicator system. In the last few years, IORT facilities have proliferated around the world. The IORT technique and the applicator systems used at these facilities vary greatly in sophistication and design philosophy. The IORT beam characteristics vary for different designs of applicator systems. It is necessary to document the existing techniques of IORT, to detail the dosimetry data required for accurate delivery of the prescribed dose, and to have a uniform method of dose specification for cooperative clinical trials. The specific charge to the task group includes the following: (a) identify the multidisciplinary IORT team, (b) outline special considerations that must be addressed by an IORT program, (c) review currently available IORT techniques, (d) describe dosimetric measurements necessary for accurate delivery of prescribed dose, (e) describe dosimetric measurements necessary in documenting doses to the surrounding normal tissues, (f) recommend quality assurance procedures for IORT, (g) review methods of treatment documentation and verification, and (h) recommend methods of dose specification and recording for cooperative clinical trials

  7. Optimizing Radiation Therapy Quality Assurance in Clinical Trials: A TROG 08.03 RAVES Substudy

    Energy Technology Data Exchange (ETDEWEB)

    Trada, Yuvnik, E-mail: yuvnik@gmail.com [Calvary Mater Newcastle, Waratah, New South Wales (Australia); Kneebone, Andrew [Royal North Shore Hospital, St Lenoards, New South Wales (Australia); Paneghel, Andrea [Peter MacCallum Cancer Centre, Melbourne, Victoria (Australia); Pearse, Maria [Auckland Hospital, Auckland (New Zealand); Sidhom, Mark [Liverpool Hospital, Liverpool, New South Wales (Australia); Tang, Colin [Sir Charles Gairdner Hospital, Nedlands, Western Australia (Australia); Wiltshire, Kirsty; Haworth, Annette [Peter MacCallum Cancer Centre, Melbourne, Victoria (Australia); Fraser-Browne, Carol [Auckland Hospital, Auckland (New Zealand); Martin, Jarad [Calvary Mater Newcastle, Waratah, New South Wales (Australia)

    2015-12-01

    Purpose: To explore site- and clinician-level factors associated with protocol violations requiring real-time-review (RTR) resubmission in a multicenter clinical trial to help tailor future quality assurance (QA) protocols. Methods and Materials: RAVES (Radiation Therapy–Adjuvant vs Early Salvage) (Trans-Tasman Radiation Oncology Group 08.03) is a randomized trial comparing adjuvant with early salvage radiation therapy in men with positive surgical margins or pT3 disease after prostatectomy. Quality assurance in RAVES required each clinician and site to submit a credentialing dummy run (DR) and for each patient's radiation therapy plan to undergo external RTR before treatment. Prospectively defined major violations from trial protocol required remedy and resubmission. Site and clinician factors associated with RTR resubmission were examined using hierarchical modeling. Results: Data were collected from 171 consecutive patients, treated by 46 clinicians at 32 hospitals. There were 47 RTR resubmissions (27%) due to 65 major violations. The relative rate of resubmission decreased by 29% per year as the study progressed (odds ratio OR. 0.71, P=.02). The majority of resubmissions were due to contouring violations (39 of 65) and dosimetric violations (22 of 65). For each additional patient accrued, significant decreases in RTR resubmission were seen at both clinician level (OR 0.75, P=.02) and site level (OR 0.72, P=.01). The rate of resubmission due to dosimetric violations was only 1.6% after the first 5 patients. Use of IMRT was associated with lower rates of resubmission compared with 3-dimensional conformal radiation therapy (OR 0.38, P=.05). Conclusion: Several low- and high-risk factors that may assist with tailoring future clinical trial QA were identified. Because the real-time resubmission rate was largely independent of the credentialing exercise, some form of RTR QA is recommended. The greatest benefit from QA was derived early in trial activation

  8. Dosimetric essay in dental radiology

    International Nuclear Information System (INIS)

    Lopez Salaberry, M.

    1998-01-01

    A neck study was observated in the tiroids glands,laryngeal zone, sensitive organs for the ionizing radiation for increase dental xray exams. Was selected 29th patients with radiography prescription complete (in the Odontology Faculty Clinics Uruguaian). It took radiographies with and without tiroids necklace and apron lead using dosemeters. Dosimetric studies had demonstrated good dose between patients. For measuring the radiation dose have been used TLD thermoluminescence dosimetric and Harshaw 6600 for read it. The thyroids necklace use and odontology postgrading for training course for dentistry was the two recommendations advised

  9. SU-E-T-125: Dosimetric Comparison of Intensity Modulated Radiation Therapy Using Robotic Versus Traditional Linac Platform in Prostate Cancer

    International Nuclear Information System (INIS)

    Hayes, T; Rella, J; Yang, J; Sims, C; Fung, C

    2014-01-01

    Purpose: Recent development of an MLC for robotic external beam radiotherapy has the potential of new clinical application in conventionally fractionated radiation therapy. This study offers a dosimetric comparison of IMRT plans using Cyberknife with MLC versus conventional linac plans. Methods: Ten prostate cancer patients treated on a traditional linac with IMRT to 7920cGy at 180cGy/fraction were randomly selected. GTVs were defined as prostate plus proximal seminal vesicles. PTVs were defined as GTV+8mm in all directions except 5mm posteriorly. Conventional IMRT planning was performed on Philips Pinnacle and delivered on a standard linac with CBCT and 10mm collimator leaf width. For each case a Cyberknife plan was created using Accuray Multiplan with same CT data set, contours, and dose constraints. All dosimetric data was transferred to third party software for independent computation of contour volumes and DVH. Delivery efficiency was evaluated using total MU, treatment time, number of beams, and number of segments. Results: Evaluation criteria including percent target coverage, homogeneity index, and conformity index were found to be comparable. All dose constraints from QUANTEC were found to be statistically similar except rectum V50Gy and bladder V65Gy. Average rectum V50Gy was lower for robotic IMRT (30.07%±6.57) versus traditional (34.73%±3.62, p=0.0130). Average bladder V65Gy was lower for robotic (17.87%±12.74) versus traditional (21.03%±11.93, p=0.0405). Linac plans utilized 9 coplanar beams, 48.9±3.8 segments, and 19381±2399MU. Robotic plans utilized 38.4±9.0 non-coplanar beams, 85.5±21.0 segments and 42554.71±16381.54 MU. The average treatment was 15.02±0.60 minutes for traditional versus 20.90±2.51 for robotic. Conclusion: The robotic IMRT plans were comparable to the traditional IMRT plans in meeting the target volume dose objectives. Critical structure dose constraints were largely comparable although statistically significant

  10. SU-F-T-97: Outlier Identification in Radiation Therapy Knowledge Modeling

    Energy Technology Data Exchange (ETDEWEB)

    Sheng, Y [Duke University, Durham, NC (United States); Ge, Y [University of North Carolina at Charlotte, Charlotte, NC (United States); Yuan, L; Yin, F; Wu, Q [Duke University Medical Center, Durham, NC (United States); Li, T [Thomas Jefferson University, Philadelphia, PA (United States)

    2016-06-15

    Purpose: To investigate the impact of outliers on knowledge modeling in radiation therapy, and develop a systematic workflow for identifying and analyzing geometric and dosimetric outliers using pelvic cases. Methods: Four groups (G1-G4) of pelvic plans were included: G1 (37 prostate cases), G2 (37 prostate plus lymph node cases), and G3 (37 prostate bed cases) are all clinical IMRT cases. G4 are 10 plans outside G1 re-planned with dynamic-arc to simulate dosimetric outliers. The workflow involves 2 steps: 1. identify geometric outliers, assess impact and clean up; 2. identify dosimetric outliers, assess impact and clean up.1. A baseline model was trained with all G1 cases. G2/G3 cases were then individually added to the baseline model as geometric outliers. The impact on the model was assessed by comparing leverage statistic of inliers (G1) and outliers (G2/G3). Receiver-operating-characteristics (ROC) analysis was performed to determine optimal threshold. 2. A separate baseline model was trained with 32 G1 cases. Each G4 case (dosimetric outliers) was then progressively added to perturb this model. DVH predictions were performed using these perturbed models for remaining 5 G1 cases. Normal tissue complication probability (NTCP) calculated from predicted DVH were used to evaluate dosimetric outliers’ impact. Results: The leverage of inliers and outliers was significantly different. The Area-Under-Curve (AUC) for differentiating G2 from G1 was 0.94 (threshold: 0.22) for bladder; and 0.80 (threshold: 0.10) for rectum. For differentiating G3 from G1, the AUC (threshold) was 0.68 (0.09) for bladder, 0.76 (0.08) for rectum. Significant increase in NTCP started from models with 4 dosimetric outliers for bladder (p<0.05), and with only 1 dosimetric outlier for rectum (p<0.05). Conclusion: We established a systematic workflow for identifying and analyzing geometric and dosimetric outliers, and investigated statistical metrics for detecting. Results validated the

  11. Effect of treatment modality on the hypothalamic-pituitary function of patients treated with radiation therapy for pituitary adenomas: Hypothalamic dose and endocrine outcomes.

    Directory of Open Access Journals (Sweden)

    Andrew eElson

    2014-04-01

    Full Text Available Background: Both fractionated external beam radiotherapy and single fraction radiosurgery for pituitary adenomas are associated with the risk of hypothalamic-pituitary (HP axis dysfunction.Objective: To analyze the effect of treatment modality (Linac, TomoTherapy, or Gamma Knife on hypothalamic dose and correlate these with HP-Axis deficits after radiotherapy.Methods:Radiation plans of patients treated postoperatively for pituitary adenomas using Linac-based 3D Conformal Radiotherapy (CRT (n=11, TomoTherapy-based Intensity Modulated Radiation Therapy (IMRT (n=10, or Gamma Knife Stereotactic Radiosurgery (SRS(n=12 were retrospectively reviewed. Dose to the hypothalamus was analyzed and postradiotherapy hormone function including growth hormone (GH, thyroid (TSH, adrenal (ACTH, prolactin (PRL, and gonadotropins (FSH/LH were assessed. Results:Post-radiation, 13 of 27 (48% patients eligible for analysis developed at least one new hormone deficit, of which 8 of 11 (72% occurred in the Linac group, 4 of 8 (50% occurred in the TomoTherapy group, and 1 of 8 (12.5% occurred in the Gamma Knife group. Compared with fractionated techniques, Gamma Knife showed improved hypothalamic sparing for DMax Hypo, and V12Gy. For fractionated modalities, TomoTherapy showed improved dosimetric characteristics over Linac-based treatment with hypothalamic DMean (44.8 Gy vs. 26.8 Gy p=0.02, DMax (49.8 Gy vs. 39.1 Gy p=0.04, and V12Gy (100% vs. 76% p=0.004.Conclusion:Maximal dosimetric avoidance of the hypothalamus was achieved using Gamma Knife-based radiosurgery followed by TomoTherapy-based IMRT, and Linac-based 3D conformal radiation therapy, respectively.

  12. Dosimetric and non-dosimetric evaluation of PrecisePLAN computerized radiation treatment planning system

    International Nuclear Information System (INIS)

    Srinidhi, G.C.; Ramya, B.; Aswathi, Raj; Boban, Minu; Solomon, J.G.R; Vidyasagar, M.S.

    2008-01-01

    Cancer is a significant health care problem; on an average about half of all cancer patients are treated with radiation therapy worldwide. This mode of treatment uses complex technology that involves megavoltage radiation, computerized TPSs and delivery systems like MLCs, if not handled with the greatest of care, could lead to significant patient treatment errors and exposures of staff. As computer technology evolved and became more compact so did TPSs, while at the same time dose calculation algorithms and image display capabilities became more sophisticated. As part of the implementation of radiation therapy technology into clinical practice, it is important to recognize that such technology has inherent risks if not handled and administered properly

  13. Some computer graphical user interfaces in radiation therapy.

    Science.gov (United States)

    Chow, James C L

    2016-03-28

    In this review, five graphical user interfaces (GUIs) used in radiation therapy practices and researches are introduced. They are: (1) the treatment time calculator, superficial X-ray treatment time calculator (SUPCALC) used in the superficial X-ray radiation therapy; (2) the monitor unit calculator, electron monitor unit calculator (EMUC) used in the electron radiation therapy; (3) the multileaf collimator machine file creator, sliding window intensity modulated radiotherapy (SWIMRT) used in generating fluence map for research and quality assurance in intensity modulated radiation therapy; (4) the treatment planning system, DOSCTP used in the calculation of 3D dose distribution using Monte Carlo simulation; and (5) the monitor unit calculator, photon beam monitor unit calculator (PMUC) used in photon beam radiation therapy. One common issue of these GUIs is that all user-friendly interfaces are linked to complex formulas and algorithms based on various theories, which do not have to be understood and noted by the user. In that case, user only needs to input the required information with help from graphical elements in order to produce desired results. SUPCALC is a superficial radiation treatment time calculator using the GUI technique to provide a convenient way for radiation therapist to calculate the treatment time, and keep a record for the skin cancer patient. EMUC is an electron monitor unit calculator for electron radiation therapy. Instead of doing hand calculation according to pre-determined dosimetric tables, clinical user needs only to input the required drawing of electron field in computer graphical file format, prescription dose, and beam parameters to EMUC to calculate the required monitor unit for the electron beam treatment. EMUC is based on a semi-experimental theory of sector-integration algorithm. SWIMRT is a multileaf collimator machine file creator to generate a fluence map produced by a medical linear accelerator. This machine file controls

  14. Dosimetric verification of radiation therapy including intensity modulated treatments, using an amorphous-silicon electronic portal imaging device

    Science.gov (United States)

    Chytyk-Praznik, Krista Joy

    Radiation therapy is continuously increasing in complexity due to technological innovation in delivery techniques, necessitating thorough dosimetric verification. Comparing accurately predicted portal dose images to measured images obtained during patient treatment can determine if a particular treatment was delivered correctly. The goal of this thesis was to create a method to predict portal dose images that was versatile and accurate enough to use in a clinical setting. All measured images in this work were obtained with an amorphous silicon electronic portal imaging device (a-Si EPID), but the technique is applicable to any planar imager. A detailed, physics-motivated fluence model was developed to characterize fluence exiting the linear accelerator head. The model was further refined using results from Monte Carlo simulations and schematics of the linear accelerator. The fluence incident on the EPID was converted to a portal dose image through a superposition of Monte Carlo-generated, monoenergetic dose kernels specific to the a-Si EPID. Predictions of clinical IMRT fields with no patient present agreed with measured portal dose images within 3% and 3 mm. The dose kernels were applied ignoring the geometrically divergent nature of incident fluence on the EPID. A computational investigation into this parallel dose kernel assumption determined its validity under clinically relevant situations. Introducing a patient or phantom into the beam required the portal image prediction algorithm to account for patient scatter and attenuation. Primary fluence was calculated by attenuating raylines cast through the patient CT dataset, while scatter fluence was determined through the superposition of pre-calculated scatter fluence kernels. Total dose in the EPID was calculated by convolving the total predicted incident fluence with the EPID-specific dose kernels. The algorithm was tested on water slabs with square fields, agreeing with measurement within 3% and 3 mm. The

  15. Dosimetric rationale and early experience at UFPTI of thoracic proton therapy and chemotherapy in limited-stage small cell lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Colaco, Rovel J.; Huh, Soon; Nichols, Romaine; Morris, Christopher G.; Flampouri, Stella; Li, Zuofeng; Hoppe, Bradford S. [Univ. of Florida Proton Therapy Inst., Jacksonville (United States)], e-mail: bhoppe@floridaproton.org; D' Agostino, Harry [Dept. of Thoracic Surgery, Univ. of Florida Coll. of Medicine, Gainesville (United States); Pham, Dat C. [Dept. of Hematology and Medical Oncology, Univ. of Florida Coll. of Medicine, Gainesville (United States); Bajwa, Abubakr A. [Dept. of Medicine, Univ. of Florida Coll. of Medicine, Gainesville (United States)

    2013-04-15

    Background: Concurrent chemoradiotherapy (CRT) is the standard of care in patients with limited-stage small cell lung cancer (SCLC). Treatment with conventional x-ray therapy (XRT) is associated with high toxicity rates, particularly acute grade 3+ esophagitis and pneumonitis. We present outcomes for the first known series of limited-stage SCLC patients treated with proton therapy and a dosimetric comparison of lung and esophageal doses with intensity-modulated radiation therapy (IMRT). Material and methods: Six patients were treated; five concurrently and one sequentially. Five patients received 60-66 CGE in 30-34 fractions once daily and one patient received 45 CGE in 30 fractions twice daily. All six patients received prophylactic cranial irradiation. Common Terminology Criteria for Adverse Events, v3.0, was used to grade toxicity. IMRT plans were also generated and compared with proton plans. Results: The median follow-up was 12.0 months. The one-year overall and progression-free survival rates were 83% and 66%, respectively. There were no cases of acute grade 3+ esophagitis or acute grade 2+ pneumonitis, and no other acute grade 3+ non-hematological toxicities were seen. One patient with a history of pulmonary fibrosis and atrial fibrillation developed worsening symptoms four months after treatment requiring oxygen. Three patients died; two of progressive disease and one after a fall. The latter patient was disease-free at 36 months after treatment. Another patient recurred and is alive, while two patients remain disease-free at 12 months of follow-up. Proton therapy proved superior to IMRT across all esophageal and lung dose volume points. Conclusion. In this small series of SCLC patients treated with proton therapy with radical intent, treatment was well tolerated with no cases of acute grade 3+ esophagitis or acute grade 2+ pneumonitis. Dosimetric comparison showed better sparing of lung and esophagus with proton therapy. Proton therapy merits further

  16. Dosimetric rationale and early experience at UFPTI of thoracic proton therapy and chemotherapy in limited-stage small cell lung cancer

    International Nuclear Information System (INIS)

    Colaco, Rovel J.; Huh, Soon; Nichols, Romaine; Morris, Christopher G.; Flampouri, Stella; Li, Zuofeng; Hoppe, Bradford S.; D'Agostino, Harry; Pham, Dat C.; Bajwa, Abubakr A.

    2013-01-01

    Background: Concurrent chemoradiotherapy (CRT) is the standard of care in patients with limited-stage small cell lung cancer (SCLC). Treatment with conventional x-ray therapy (XRT) is associated with high toxicity rates, particularly acute grade 3+ esophagitis and pneumonitis. We present outcomes for the first known series of limited-stage SCLC patients treated with proton therapy and a dosimetric comparison of lung and esophageal doses with intensity-modulated radiation therapy (IMRT). Material and methods: Six patients were treated; five concurrently and one sequentially. Five patients received 60-66 CGE in 30-34 fractions once daily and one patient received 45 CGE in 30 fractions twice daily. All six patients received prophylactic cranial irradiation. Common Terminology Criteria for Adverse Events, v3.0, was used to grade toxicity. IMRT plans were also generated and compared with proton plans. Results: The median follow-up was 12.0 months. The one-year overall and progression-free survival rates were 83% and 66%, respectively. There were no cases of acute grade 3+ esophagitis or acute grade 2+ pneumonitis, and no other acute grade 3+ non-hematological toxicities were seen. One patient with a history of pulmonary fibrosis and atrial fibrillation developed worsening symptoms four months after treatment requiring oxygen. Three patients died; two of progressive disease and one after a fall. The latter patient was disease-free at 36 months after treatment. Another patient recurred and is alive, while two patients remain disease-free at 12 months of follow-up. Proton therapy proved superior to IMRT across all esophageal and lung dose volume points. Conclusion. In this small series of SCLC patients treated with proton therapy with radical intent, treatment was well tolerated with no cases of acute grade 3+ esophagitis or acute grade 2+ pneumonitis. Dosimetric comparison showed better sparing of lung and esophagus with proton therapy. Proton therapy merits further

  17. Dose Recalculation and the Dose-Guided Radiation Therapy (DGRT) Process Using Megavoltage Cone-Beam CT

    International Nuclear Information System (INIS)

    Cheung, Joey; Aubry, Jean-Francois; Yom, Sue S.; Gottschalk, Alexander R.; Celi, Juan Carlos; Pouliot, Jean

    2009-01-01

    Purpose: At University of California San Francisco, daily or weekly three-dimensional images of patients in treatment position are acquired for image-guided radiation therapy. These images can be used for calculating the actual dose delivered to the patient during treatment. In this article, we present the process of performing dose recalculation on megavoltage cone-beam computed tomography images and discuss possible strategies for dose-guided radiation therapy (DGRT). Materials and Methods: A dedicated workstation has been developed to incorporate the necessary elements of DGRT. Patient image correction (cupping, missing data artifacts), calibration, completion, recontouring, and dose recalculation are all implemented in the workstation. Tools for dose comparison are also included. Examples of image correction and dose analysis using 6 head-and-neck and 2 prostate patient datasets are presented to show possible tracking of interfraction dosimetric endpoint variation over the course of treatment. Results: Analysis of the head-and-neck datasets shows that interfraction treatment doses vary compared with the planning dose for the organs at risk, with the mean parotid dose and spinal cord D 1 increasing by as much as 52% and 10%, respectively. Variation of the coverage to the target volumes was small, with an average D 5 dose difference of 1%. The prostate patient datasets revealed accurate dose coverage to the targeted prostate and varying interfraction dose distributions to the organs at risk. Conclusions: An effective workflow for the clinical implementation of DGRT has been established. With these techniques in place, future clinical developments in adaptive radiation therapy through daily or weekly dosimetric measurements of treatment day images are possible.

  18. Effect of Dosimetric Factors on Occurrence and Volume of Temporal Lobe Necrosis Following Intensity Modulated Radiation Therapy for Nasopharyngeal Carcinoma: A Case-Control Study

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Xin; Ou, Xiaomin; Xu, Tingting; Wang, Xiaosheng; Shen, Chunying [Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai (China); Ding, Jianhui [Department of Diagnostic Radiology, Fudan University Shanghai Cancer Center, Shanghai (China); Hu, Chaosu, E-mail: hucsu62@yahoo.com [Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai (China)

    2014-10-01

    Purpose: To determine dosimetric risk factors for the occurrence of temporal lobe necrosis (TLN) among nasopharyngeal carcinoma (NPC) patients treated with intensity modulated radiation therapy (IMRT) and to investigate the impact of dose-volume histogram (DVH) parameters on the volume of TLN lesions (V-N). Methods and Materials: Forty-three NPC patients who had developed TLN following IMRT and 43 control subjects free of TLN were retrospectively assessed. DVH parameters included maximum dose (Dmax), minimum dose (Dmin), mean dose (Dmean), absolute volumes receiving specific dose (Vds) from 20 to 76 Gy (V20-V76), and doses covering certain volumes (Dvs) from 0.25 to 6.0 cm{sup 3} (D0.25-D6.0). V-Ns were quantified with axial magnetic resonance images. Results: DVH parameters were ubiquitously higher in temporal lobes with necrosis than in healthy temporal lobes. Increased Vds and Dvs were significantly associated with higher risk of TLN occurrence (P<.05). In particular, Vds at a dose of ≥70 Gy were found with the highest odds ratios. A common increasing trend was detected between V-N and DVH parameters through trend tests (P for trend of <.05). Linear regression analysis showed that V45 had the strongest predictive power for V-N (adjusted R{sup 2} = 0.305, P<.0001). V45 of <15.1 cm{sup 3} was relatively safe as the dose constraint for preventing large TLN lesions with V-N of >5 cm{sup 3}. Conclusions: Dosimetric parameters are significantly associated with TLN occurrence and the extent of temporal lobe injury. To better manage TLN, it would be important to avoid both focal high dose and moderate dose delivered to a large area in TLs.

  19. Adaptive Stereotactic Body Radiation Therapy Planning for Lung Cancer

    International Nuclear Information System (INIS)

    Qin, Yujiao; Zhang, Fan; Yoo, David S.; Kelsey, Chris R.; Yin, Fang-Fang; Cai, Jing

    2013-01-01

    Purpose: To investigate the dosimetric effects of adaptive planning on lung stereotactic body radiation therapy (SBRT). Methods and Materials: Forty of 66 consecutive lung SBRT patients were selected for a retrospective adaptive planning study. CBCT images acquired at each fraction were used for treatment planning. Adaptive plans were created using the same planning parameters as the original CT-based plan, with the goal to achieve comparable comformality index (CI). For each patient, 2 cumulative plans, nonadaptive plan (P NON ) and adaptive plan (P ADP ), were generated and compared for the following organs-at-risks (OARs): cord, esophagus, chest wall, and the lungs. Dosimetric comparison was performed between P NON and P ADP for all 40 patients. Correlations were evaluated between changes in dosimetric metrics induced by adaptive planning and potential impacting factors, including tumor-to-OAR distances (d T-OAR ), initial internal target volume (ITV 1 ), ITV change (ΔITV), and effective ITV diameter change (Δd ITV ). Results: 34 (85%) patients showed ITV decrease and 6 (15%) patients showed ITV increase throughout the course of lung SBRT. Percentage ITV change ranged from −59.6% to 13.0%, with a mean (±SD) of −21.0% (±21.4%). On average of all patients, P ADP resulted in significantly (P=0 to .045) lower values for all dosimetric metrics. Δd ITV /d T-OAR was found to correlate with changes in dose to 5 cc (ΔD5cc) of esophagus (r=0.61) and dose to 30 cc (ΔD30cc) of chest wall (r=0.81). Stronger correlations between Δd ITV /d T-OAR and ΔD30cc of chest wall were discovered for peripheral (r=0.81) and central (r=0.84) tumors, respectively. Conclusions: Dosimetric effects of adaptive lung SBRT planning depend upon target volume changes and tumor-to-OAR distances. Adaptive lung SBRT can potentially reduce dose to adjacent OARs if patients present large tumor volume shrinkage during the treatment

  20. Adaptive Stereotactic Body Radiation Therapy Planning for Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Qin, Yujiao [Medical Physics Graduate Program, Duke University, Durham, North Carolina (United States); Zhang, Fan [Occupational and Environmental Safety Office, Duke University Medical Center, Durham, North Carolina (United States); Yoo, David S.; Kelsey, Chris R. [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States); Yin, Fang-Fang [Medical Physics Graduate Program, Duke University, Durham, North Carolina (United States); Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States); Cai, Jing, E-mail: jing.cai@duke.edu [Medical Physics Graduate Program, Duke University, Durham, North Carolina (United States); Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States)

    2013-09-01

    Purpose: To investigate the dosimetric effects of adaptive planning on lung stereotactic body radiation therapy (SBRT). Methods and Materials: Forty of 66 consecutive lung SBRT patients were selected for a retrospective adaptive planning study. CBCT images acquired at each fraction were used for treatment planning. Adaptive plans were created using the same planning parameters as the original CT-based plan, with the goal to achieve comparable comformality index (CI). For each patient, 2 cumulative plans, nonadaptive plan (P{sub NON}) and adaptive plan (P{sub ADP}), were generated and compared for the following organs-at-risks (OARs): cord, esophagus, chest wall, and the lungs. Dosimetric comparison was performed between P{sub NON} and P{sub ADP} for all 40 patients. Correlations were evaluated between changes in dosimetric metrics induced by adaptive planning and potential impacting factors, including tumor-to-OAR distances (d{sub T-OAR}), initial internal target volume (ITV{sub 1}), ITV change (ΔITV), and effective ITV diameter change (Δd{sub ITV}). Results: 34 (85%) patients showed ITV decrease and 6 (15%) patients showed ITV increase throughout the course of lung SBRT. Percentage ITV change ranged from −59.6% to 13.0%, with a mean (±SD) of −21.0% (±21.4%). On average of all patients, P{sub ADP} resulted in significantly (P=0 to .045) lower values for all dosimetric metrics. Δd{sub ITV}/d{sub T-OAR} was found to correlate with changes in dose to 5 cc (ΔD5cc) of esophagus (r=0.61) and dose to 30 cc (ΔD30cc) of chest wall (r=0.81). Stronger correlations between Δd{sub ITV}/d{sub T-OAR} and ΔD30cc of chest wall were discovered for peripheral (r=0.81) and central (r=0.84) tumors, respectively. Conclusions: Dosimetric effects of adaptive lung SBRT planning depend upon target volume changes and tumor-to-OAR distances. Adaptive lung SBRT can potentially reduce dose to adjacent OARs if patients present large tumor volume shrinkage during the treatment.

  1. Plastic scintillation dosimetry for radiation therapy: minimizing capture of Cerenkov radiation noise

    International Nuclear Information System (INIS)

    Beddar, A Sam; Suchowerska, Natalka; Law, Susan H

    2004-01-01

    Over the last decade, there has been an increased interest in scintillation dosimetry using small water-equivalent plastic scintillators, because of their favourable characteristics when compared with other more commonly used detector systems. Although plastic scintillators have been shown to have many desirable dosimetric properties, as yet there is no successful commercial detector system of this type available for routine clinical use in radiation oncology. The main factor preventing this new technology from realizing its full potential in commercial applications is the maximization of signal coupling efficiency and the minimization of noise capture. A principal constituent of noise is Cerenkov radiation. This study reports the calculated capture of Cerenkov radiation by an optical fibre in the special case where the radiation is generated by a relativistic particle on the fibre axis and the fibre axis is parallel to the Cerenkov cone. The fraction of radiation captured is calculated as a function of the fibre core refractive index and the refractive index difference between the core and the cladding of the fibre for relativistic particles. This is then used to deduce the relative intensity captured for a range of fibre core refractive indices and fibre core-cladding refractive index differences. It is shown that the core refractive index has little effect on the amount of radiation captured compared to the refractive index difference. The implications of this result for the design of radiation therapy plastic scintillation dosimeters are considered

  2. Stereotactic Body Radiation Therapy for Re-irradiation of Persistent or Recurrent Non-Small Cell Lung Cancer

    International Nuclear Information System (INIS)

    Trovo, Marco; Minatel, Emilio; Durofil, Elena; Polesel, Jerry; Avanzo, Michele; Baresic, Tania; Bearz, Alessandra; Del Conte, Alessandro; Franchin, Giovanni; Gobitti, Carlo; Rumeileh, Imad Abu; Trovo, Mauro G.

    2014-01-01

    Purpose: To retrospectively assess toxicity and outcome of re-irradiation with stereotactic body radiation therapy (SBRT) in patients with recurrent or persistent non-small cell lung cancer (NSCLC), who were previously treated with radical radiation therapy (50-60 Gy). The secondary endpoint was to investigate whether there are dosimetric parameter predictors of severe radiation toxicity. Methods and Materials: The analysis was conducted in 17 patients with “in-field” recurrent/persistent centrally located NSCLC, who underwent re-irradiation with SBRT. SBRT consisted of 30 Gy in 5 to 6 fractions; these prescriptions would be equivalent for the tumor to 37.5 to 40 Gy, bringing the total 2-Gy-per-fraction cumulative dose to 87 to 100 Gy, considering the primary radiation therapy treatment. Actuarial analyses and survival were calculated by the Kaplan-Meier method, and P values were estimated by the log-rank test, starting from the date of completion of SBRT. Dosimetric parameters from the subgroups with and without grade ≥3 pulmonary toxicity were compared using a 2-tailed Student t test. Results: The median follow-up was 18 months (range, 4-57 months). Only 2 patients had local failure, corresponding to a local control rate of 86% at 1 year. The Kaplan-Meier estimates of overall survival (OS) rates at 1 and 2 years were 59% and 29%, respectively; the median OS was 19 months. Four patients (23%) experienced grade 3 radiation pneumonitis, and 1 patient developed fatal pneumonitis. One patient died of fatal hemoptysis 2 months after the completion of SBRT. Unexpectedly, heart maximum dose, D5 (minimum dose to at least 5% of the heart volume), and D10 were correlated with risk of radiation pneumonitis (P<.05). Conclusions: Re-irradiation with SBRT for recurrent/persistent centrally located NSCLC achieves excellent results in terms of local control. However, the high rate of severe toxicity reported in our study is of concern

  3. Stereotactic Body Radiation Therapy for Re-irradiation of Persistent or Recurrent Non-Small Cell Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Trovo, Marco, E-mail: marcotrovo33@hotmail.com [Department of Radiation Oncology, Centro di Riferimento Oncologico of Aviano, Pordenone (Italy); Minatel, Emilio; Durofil, Elena [Department of Radiation Oncology, Centro di Riferimento Oncologico of Aviano, Pordenone (Italy); Polesel, Jerry [Department of Epidemiology and Biostatistics, Centro di Riferimento Oncologico of Aviano, Pordenone (Italy); Avanzo, Michele [Department of Medical Physics, Centro di Riferimento Oncologico of Aviano, Pordenone (Italy); Baresic, Tania [Department of Nuclear Medicine, Centro di Riferimento Oncologico of Aviano, Pordenone (Italy); Bearz, Alessandra [Department of Medical Oncology, Centro di Riferimento Oncologico of Aviano, Pordenone (Italy); Del Conte, Alessandro [Department of Medical Oncology, Pordenone General Hospital, Aviano, Pordenone (Italy); Franchin, Giovanni; Gobitti, Carlo; Rumeileh, Imad Abu; Trovo, Mauro G. [Department of Radiation Oncology, Centro di Riferimento Oncologico of Aviano, Pordenone (Italy)

    2014-04-01

    Purpose: To retrospectively assess toxicity and outcome of re-irradiation with stereotactic body radiation therapy (SBRT) in patients with recurrent or persistent non-small cell lung cancer (NSCLC), who were previously treated with radical radiation therapy (50-60 Gy). The secondary endpoint was to investigate whether there are dosimetric parameter predictors of severe radiation toxicity. Methods and Materials: The analysis was conducted in 17 patients with “in-field” recurrent/persistent centrally located NSCLC, who underwent re-irradiation with SBRT. SBRT consisted of 30 Gy in 5 to 6 fractions; these prescriptions would be equivalent for the tumor to 37.5 to 40 Gy, bringing the total 2-Gy-per-fraction cumulative dose to 87 to 100 Gy, considering the primary radiation therapy treatment. Actuarial analyses and survival were calculated by the Kaplan-Meier method, and P values were estimated by the log-rank test, starting from the date of completion of SBRT. Dosimetric parameters from the subgroups with and without grade ≥3 pulmonary toxicity were compared using a 2-tailed Student t test. Results: The median follow-up was 18 months (range, 4-57 months). Only 2 patients had local failure, corresponding to a local control rate of 86% at 1 year. The Kaplan-Meier estimates of overall survival (OS) rates at 1 and 2 years were 59% and 29%, respectively; the median OS was 19 months. Four patients (23%) experienced grade 3 radiation pneumonitis, and 1 patient developed fatal pneumonitis. One patient died of fatal hemoptysis 2 months after the completion of SBRT. Unexpectedly, heart maximum dose, D5 (minimum dose to at least 5% of the heart volume), and D10 were correlated with risk of radiation pneumonitis (P<.05). Conclusions: Re-irradiation with SBRT for recurrent/persistent centrally located NSCLC achieves excellent results in terms of local control. However, the high rate of severe toxicity reported in our study is of concern.

  4. Radiation hazards in uranium mining. Epidemiological and dosimetric approaches

    International Nuclear Information System (INIS)

    Myers, D.K.; Johnson, J.R.

    1989-01-01

    Potential health hazards resulting from exposure to various sources of radiation associated with uranium mining have been reviewed: 1) epidemiological observations on groups of miners exposed in the past to high concentrations of radon progeny have been interpreted to suggest a lifetime risk of about 3 x 10 -4 lung cancers per WLM; 2) the total risk of serious health effects resulting from exposure of workers to whole body gamma-radiation might be taken to be about 2 x 10 -2 per Sv; and 3) the potential health effects of inhalation of thoron progeny or of radioactive ore dusts can only be estimated from dosimetric calculations. A review of the uncertainties involved in these calculations suggests that ICRP estimates of the potential toxicity of inhaled thoron progeny are as good as those for inhaled radon progeny. However, the potential health hazards from inhaled uranium and thorium ore dusts have probably been overestimated by a factor of 2 to 10-fold

  5. Dosimetric intercomparison between protons and electrons therapies applied to retinoblastoma

    International Nuclear Information System (INIS)

    Braga, Flavia Vieira

    2008-01-01

    In this work we propose a construction of a simple human eye model in order to simulate the dosimetric response for a treatment with protons and electrons in a retinoblastoma cancer. The computational tool used in this simulation was the Geant4 code, in the version 4.9.1, all these package are free and permit simulate the interaction of radiation with matter. In our simulation we use a box with 4 cm side, with water, for represent the human eye. The simulation was performed considering mono energetics beams of protons and electrons with energy range between 50 and 70 MeV for protons and 2 and 10 MeV for electrons. The simulation was based on the advanced hadron therapy example of the Geant 4 code. In these example the phantom is divided in voxels with 0.2 mm side and it is generated the energy deposited in each voxel. The simulation results show the energy deliver in each voxel, with these energie we can calculate the dose deposited in that region. We can see the dose profile of, proton and electron, and we can see in both cases that for protons the position of delivered dose is well know, that happen in the position where the proton stop, for electrons the energies is delivered along the way and pass the desired position for high dose deposition. (author)

  6. Dosimetric characteristics and radiation monitoring with CaSO4(Dy):NaCl pellets

    International Nuclear Information System (INIS)

    Kathuria, S.P.; Campos, L.L.; Gordon, A.M.P.L.

    1981-06-01

    CaSO 4 (Dy):NaCl Tl dosimeters, in the form of pellets, are used in the field for a period of one month. Before using these pellets for environmental and personnel radiation monitoring some of the important dosimetric characteristics like fading reusability and effect of ambient light are investigated and described. The pellets are used with plastic and lead filters for personnel and environmental radiation monitoring and the results obtained with the lead filters are in good agreement with those of the energy independent LiF dosimeters. A new combination of plastic, aluminium and lead filters is suggested for dose measurements in a mixed field of X, gamma and beta radiations. (Author) [pt

  7. Three dimensional conformal radiation therapy in pediatric parameningeal rhabdomyosarcomas

    International Nuclear Information System (INIS)

    Michalski, Jeff M.; Harms, William B.; Purdy, James A.; Sur, Ranjan K.

    1995-01-01

    Purpose: We evaluated the utility of three dimensional (3D) treatment planning in the management of children with parameningeal head and neck rhabdomyosarcomas. Methods and Materials: Five children with parameningeal rhabdomyosarcoma were referred for treatment at our radiation oncology center from May 1990 through January 1993. Each patient was evaluated, staged, and treated according to the Intergroup Rhabdomyosarcoma Study. Patients were immobilized and underwent a computed tomography scan with contrast in the treatment position. Tumor and normal tissues were identified with assistance from a diagnostic radiologist and defined in each slice. The patients were then planned and treated with the assistance of a 3D treatment planning system. A second plan was then devised by another physician without the benefit of the 3D volumetric display. The target volumes designed with the 3D system and the two-dimensional (2D) method were then compared. The dosimetric coverage to tumor, tumor plus margin, and normal tissues was also compared with the two methods of treatment planning. Results: The apparent size of the gross tumor volume was underestimated with the conventional 2D planning method relative to the 3D method. When margin was added around the gross tumor to account for microscopic extension of disease in the 2D method, the expected area of coverage improved relative to the 3D method. In each circumstance, the minimum dose that covered the gross tumor was substantially less with the 2D method than with the 3D method. The inadequate dosimetric coverage was especially pronounced when the necessary margin to account for subclinical disease was added. In each case, the 2D plans would have delivered substantial dose to adjacent normal tissues and organs, resulting in a higher incidence of significant complications. Conclusions: 3D conformal radiation therapy has a demonstrated advantage in the treatment of sarcomas of the head and neck. The improved dosimetric coverage

  8. Replanning Criteria and Timing Definition for Parotid Protection-Based Adaptive Radiation Therapy in Nasopharyngeal Carcinoma

    Directory of Open Access Journals (Sweden)

    Wei-Rong Yao

    2015-01-01

    Full Text Available The goal of this study was to evaluate real-time volumetric and dosimetric changes of the parotid gland so as to determine replanning criteria and timing for parotid protection-based adaptive radiation therapy in nasopharyngeal carcinoma. Fifty NPC patients were treated with helical tomotherapy; volumetric and dosimetric (Dmean, V1, and D50 changes of the parotid gland at the 1st, 6th, 11th, 16th, 21st, 26th, 31st, and 33rd fractions were evaluated. The clinical parameters affecting these changes were studied by analyses of variance methods for repeated measures. Factors influencing the actual parotid dose were analyzed by a multivariate logistic regression model. The cut-off values predicting parotid overdose were developed from receiver operating characteristic curves and judged by combining them with a diagnostic test consistency check. The median absolute value and percentage of parotid volume reduction were 19.51 cm3 and 35%, respectively. The interweekly parotid volume varied significantly (p<0.05. The parotid Dmean, V1, and D50 increased by 22.13%, 39.42%, and 48.45%, respectively. The actual parotid dose increased by an average of 11.38% at the end of radiation therapy. Initial parotid volume, initial parotid Dmean, and weight loss rate are valuable indicators for parotid protection-based replanning.

  9. Phantom dosimetry at 15 MV conformal radiation therapy

    International Nuclear Information System (INIS)

    Thompson, Larissa; Campos, Tarcisio P.R.; Dias, Humberto G.

    2013-01-01

    The main goal of this work was to evaluate the spatial dose distribution into a tumor simulator inside a head phantom exposed to a 15MV 3D conformal radiation therapy in order to validate internal doses. A head and neck phantom developed by the Ionizing Radiation Research Group (NRI) was used on the experiments. Therapy Radiation planning (TPS) was performed based on those CT images, satisfying a 200 cGy prescribed dose split in three irradiation fields. The TPS assumed 97% of prescribed dose cover the prescribed treatment volume (PTV). Radiochromic films in a solid water phantom provided dose response as a function of optical density. Spatial dosimetric distribution was generated by radiochromic film samples inserted into tumor simulator and brain. The spatial dose profiles held 70 to 120% of the prescribed dose. In spite of the stratified profile, as opposed to the smooth dose profile from TPS, the tumor internal doses were within a 5% deviation from 214.4 cGy evaluated by TPS. 83.2% of the points with a gamma value of less than 1 (3%/3mm) for TPS and experimental values, respectively. At the tumor, a few dark spots in the film caused the appearance of outlier points in 13-15% of dose deviation percentage. As final conclusion, such dosimeter choice and the physical anthropomorphic and anthropometric phantom provided an efficient method for validating radiotherapy protocols. (author)

  10. Phantom dosimetry at 15 MV conformal radiation therapy

    International Nuclear Information System (INIS)

    Thompson, Larissa; Campos, Tarcisio P.R.

    2015-01-01

    The main goal of this work was to evaluate the spatial dose distribution into a tumor simulator inside a head phantom exposed to a 15MV 3D conformal radiation therapy in order to validate internal doses. A head and neck phantom developed by the Ionizing Radiation Research Group (NRI) was used on the experiments. Therapy Radiation planning (TPS) was performed based on those CT images, satisfying a 200 cGy prescribed dose split in three irradiation fields. The TPS assumed 97% of prescribed dose cover the prescribed treatment volume (PTV). Radiochromic films in a solid water phantom provided dose response as a function of optical density. Spatial dosimetric distribution was generated by radiochromic film samples inserted into tumor simulator and brain. The spatial dose profiles held 70 to 120% of the prescribed dose. In spite of the stratified profile, as opposed to the smooth dose profile from TPS, the tumor internal doses were within a 5% deviation from 214.4 cGy evaluated by TPS. 83.2% of the points with a gamma value of less than 1 (3%/3mm) for TPS and experimental values, respectively. At the tumor, a few dark spots in the film caused the appearance of outlier points in 13-15% of dose deviation percentage. As final conclusion, such dosimeter choice and the physical anthropomorphic and anthropometric phantom provided an efficient method for validating radiotherapy protocols. (author)

  11. Potential dosimetric benefits of adaptive tumor tracking over the internal target volume concept for stereotactic body radiation therapy of pancreatic cancer.

    Science.gov (United States)

    Karava, Konstantina; Ehrbar, Stefanie; Riesterer, Oliver; Roesch, Johannes; Glatz, Stefan; Klöck, Stephan; Guckenberger, Matthias; Tanadini-Lang, Stephanie

    2017-11-09

    Radiotherapy for pancreatic cancer has two major challenges: (I) the tumor is adjacent to several critical organs and, (II) the mobility of both, the tumor and its surrounding organs at risk (OARs). A treatment planning study simulating stereotactic body radiation therapy (SBRT) for pancreatic tumors with both the internal target volume (ITV) concept and the tumor tracking approach was performed. The two respiratory motion-management techniques were compared in terms of doses to the target volume and organs at risk. Two volumetric-modulated arc therapy (VMAT) treatment plans (5 × 5 Gy) were created for each of the 12 previously treated pancreatic cancer patients, one using the ITV concept and one the tumor tracking approach. To better evaluate the overall dose delivered to the moving tumor volume, 4D dose calculations were performed on four-dimensional computed tomography (4DCT) scans. The resulting planning target volume (PTV) size for each technique was analyzed. Target and OAR dose parameters were reported and analyzed for both 3D and 4D dose calculation. Tumor motion ranged from 1.3 to 11.2 mm. Tracking led to a reduction of PTV size (max. 39.2%) accompanied with significant better tumor coverage (p<0.05, paired Wilcoxon signed rank test) both in 3D and 4D dose calculations and improved organ at risk sparing. Especially for duodenum, stomach and liver, the mean dose was significantly reduced (p<0.05) with tracking for 3D and 4D dose calculations. By using an adaptive tumor tracking approach for respiratory-induced pancreatic motion management, a significant reduction in PTV size can be achieved, which subsequently facilitates treatment planning, and improves organ dose sparing. The dosimetric benefit of tumor tracking is organ and patient-specific.

  12. Hypofractionated Whole-Breast Radiation Therapy: Does Breast Size Matter?

    International Nuclear Information System (INIS)

    Hannan, Raquibul; Thompson, Reid F.; Chen Yu; Bernstein, Karen; Kabarriti, Rafi; Skinner, William; Chen, Chin C.; Landau, Evan; Miller, Ekeni; Spierer, Marnee; Hong, Linda; Kalnicki, Shalom

    2012-01-01

    Purpose: To evaluate the effects of breast size on dose-volume histogram parameters and clinical toxicity in whole-breast hypofractionated radiation therapy using intensity modulated radiation therapy (IMRT). Materials and Methods: In this retrospective study, all patients undergoing breast-conserving therapy between 2005 and 2009 were screened, and qualifying consecutive patients were included in 1 of 2 cohorts: large-breasted patients (chest wall separation >25 cm or planning target volume [PTV] >1500 cm 3 ) (n=97) and small-breasted patients (chest wall separation 3 ) (n=32). All patients were treated prone or supine with hypofractionated IMRT to the whole breast (42.4 Gy in 16 fractions) followed by a boost dose (9.6 Gy in 4 fractions). Dosimetric and clinical toxicity data were collected and analyzed using the R statistical package (version 2.12). Results: The mean PTV V95 (percentage of volume receiving >= 95% of prescribed dose) was 90.18% and the mean V105 percentage of volume receiving >= 105% of prescribed dose was 3.55% with no dose greater than 107%. PTV dose was independent of breast size, whereas heart dose and maximum point dose to skin correlated with increasing breast size. Lung dose was markedly decreased in prone compared with supine treatments. Radiation Therapy Oncology Group grade 0, 1, and 2 skin toxicities were noted acutely in 6%, 69%, and 25% of patients, respectively, and at later follow-up (>3 months) in 43%, 57%, and 0% of patients, respectively. Large breast size contributed to increased acute grade 2 toxicity (28% vs 12%, P=.008). Conclusions: Adequate PTV coverage with acceptable hot spots and excellent sparing of organs at risk was achieved by use of IMRT regardless of treatment position and breast size. Although increasing breast size leads to increased heart dose and maximum skin dose, heart dose remained within our institutional constraints and the incidence of overall skin toxicity was comparable to that reported in the

  13. Dosimetric comparison of vaginal vault ovoid brachytherapy versus intensity-modulated radiation therapy plans in postoperative patients of cervical carcinoma following whole pelvic radiotherapy

    Directory of Open Access Journals (Sweden)

    Divya Khosla

    2014-01-01

    Full Text Available Introduction: Dosimetric study to compare high dose rate (HDR vaginal vault ovoid brachytherapy plan versus intensity-modulated radiation therapy (IMRT boost plan for doses delivered to target volume and organs at risk (OAR in postoperative patients of cervical carcinoma following whole pelvic radiotherapy (WPRT. Materials and Methods: Fifteen postoperative patients of cervical carcinoma suitable for vaginal ovoid brachytherapy following WPRT of 46 Gy/23 fractions/4.5 weeks were included. All were treated with brachytherapy (two sessions of 8.5 Gy each. The equivalent dose for IMRT was calculated by computing biologically effective dose of brachytherapy by linear quadratic model. Dose of brachytherapy (two sessions of 8.5 Gy was equivalent to IMRT dose of 26 Gy/13 fractions. Doses to target volume and OAR were compared between HDR and IMRT plans. Results: Target volume was well covered with both HDR and IMRT plans, but dose with brachytherapy was much higher (P < 0.05. Mean doses, doses to 0.1, 1, 2, and 5cc, 1/3 rd , 1/2, and 2/3 rd volume of bladder and rectum were significantly lower with HDR plans. Conclusion: In postoperative patients of cervical carcinoma, HDR brachytherapy following WPRT appears to be better than IMRT for tumor coverage and reducing dose to critical organs.

  14. Dosimetric impact of inter-observer variability for 3D conformal radiotherapy and volumetric modulated arc therapy: the rectal tumor target definition case

    International Nuclear Information System (INIS)

    Lobefalo, Francesca; Cozzi, Luca; Scorsetti, Marta; Mancosu, Pietro; Bignardi, Mario; Reggiori, Giacomo; Tozzi, Angelo; Tomatis, Stefano; Alongi, Filippo; Fogliata, Antonella; Gaudino, Anna; Navarria, Piera

    2013-01-01

    To assess the dosimetric effect induced by inter-observer variability in target definition for 3D-conformal RT (3DCRT) and volumetric modulated arc therapy by RapidArc (RA) techniques for rectal cancer treatment. Ten patients with rectal cancer subjected to neo-adjuvant RT were randomly selected from the internal database. Four radiation oncologists independently contoured the clinical target volume (CTV) in blind mode. Planning target volume (PTV) was defined as CTV + 7 mm in the three directions. Afterwards, shared guidelines between radiation oncologists were introduced to give general criteria for the contouring of rectal target and the four radiation oncologists defined new CTV following the guidelines. For each patient, six intersections (I) and unions (U) volumes were calculated coupling the contours of the various oncologists. This was repeated for the contours drawn after the guidelines. Agreement Index (AI = I/U) was calculated pre and post guidelines. Two RT plans (one with 3DCRT technique using 3–4 fields and one with RA using a single modulated arc) were optimized on each radiation oncologist’s PTV. For each plan the PTV volume receiving at least 95% of the prescribed dose (PTV V95%) was calculated for both target and non-target PTVs. The inter-operator AI pre-guidelines was 0.57 and was increased up to 0.69 post-guidelines. The maximum volume difference between the various CTV couples, drawn for each patient, passed from 380 ± 147 cm 3 to 137 ± 83 cm 3 after the introduction of guidelines. The mean percentage for the non-target PTV V95% was 93.7 ± 9.2% before and 96.6 ± 4.9%after the introduction of guidelines for the 3DCRT, for RA the increase was more relevant, passing from 86.5 ± 13.8% (pre) to 94.5 ± 7.5% (post). The OARs were maximally spared with VMAT technique while the variability between pre and post guidelines was not relevant in both techniques. The contouring inter-observer variability has dosimetric effects in the PTV coverage

  15. Dosimetric aspects of radiation processing of food and allied products

    International Nuclear Information System (INIS)

    Sharma, G.; Bhat, R.M.; Bhatt, B.C.

    2010-01-01

    Full text: Gamma radiation processing in the last 4-5 decades is continuously gaining importance in processing of a wide variety of products, as it can modify physical, chemical and biological properties of the materials, including food and allied products on industrial scale due its inherent qualities like ease of processing in finally packaged form, eco-friendly nature and other obvious reasons over conventional means of processing. Food and allied products are either from agricultural produce or animal origin; they get easily contaminated from soil during harvesting, handling, processing, environment conditions, storage and transport from various types of micro-organisms including pathogens. In many countries it is mandatory to bring down the population of micro-organisms to an acceptable level and complete elimination of pathogens before such products are accepted for human or animal consumption. Processing of food and allied products by radiation has its own challenges due to wider public acceptance of irradiated food, a wide range, 0.25-50kGy, of absorbed dose requirements for different category of such products and purposes, use of a variety of packaging materials in different shapes and sizes and because of its perishable nature. More than 50 countries including India in the world have accepted radiation processing of food and allied products by radiation. Dosimetry is an important aspect of radiation processing, whether it is food or allied product. Uniformity in dose delivered to these products depends on several factors such as product carrier to source frame alignment, product carrier and product/tote box design, product loading pattern, attenuation due to product thickness, product bulk density that varies from 0.1-1.0 kg/l and the plant design whether during processing product overlaps the source or otherwise. In this presentation dosimetric aspects of radiation processing of food and allied products and problems associated with dosimetry of such

  16. Dosimetric effect of beam arrangement for intensity-modulated radiation therapy in the treatment of upper thoracic esophageal carcinoma

    International Nuclear Information System (INIS)

    Fu, Yuchuan; Deng, Min; Zhou, Xiaojuan; Lin, Qiang; Du, Bin; Tian, Xue; Xu, Yong; Wang, Jin; Lu, You; Gong, Youling

    2017-01-01

    To evaluate the lung sparing in intensity-modulated radiation therapy (IMRT) for patients with upper thoracic esophageal tumors extending inferiorly to the thorax by different beam arrangement. Overall, 15 patient cases with cancer of upper thoracic esophagus were selected for a retrospective treatment-planning study. Intensity-modulated radiation therapy plans using 4, 5, and 7 beams (4B, 5B, and 7B) were developed for each patient by direct machine parameter optimization (DMPO). All plans were evaluated with respect to dose volumes to irradiated targets and normal structures, with statistical comparisons made between 4B with 5B and 7B intensity-modulated radiation therapy plans. Differences among plans were evaluated using a two-tailed Friedman test at a statistical significance of p < 0.05. The maximum dose, average dose, and the conformity index (CI) of planning target volume 1 (PTV1) were similar for 3 plans for each case. No significant difference of coverage for planning target volume 1 and maximum dose for spinal cords were observed among 3 plans in present study (p > 0.05). The average V 5 , V 13 , V 20 , mean lung dose, and generalized equivalent uniform dose (gEUD) for the total lung were significantly lower in 4B-plans than those data in 5B-plans and 7B-plans (p < 0.01). Although the average V 30 for the total lung were significantly higher in 4B-plans than those in 5B-plans and 7B-plans (p < 0.05). In addition, when comparing with the 4B-plans, the conformity/heterogeneity index of the 5B- and 7B-plans were significantly superior (p < 0.05). The 4B-intensity-modulated radiation therapy plan has advantage to address the specialized problem of lung sparing to low- and intermediate-dose exposure in the thorax when dealing with relative long tumors extended inferiorly to the thoracic esophagus for upper esophageal carcinoma with the cost for less conformity. Studies are needed to compare the superiority of volumetric modulated arc therapy with intensity

  17. Dosimetric effect of beam arrangement for intensity-modulated radiation therapy in the treatment of upper thoracic esophageal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Yuchuan [Division of Radiation Physics, State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu (China); Deng, Min; Zhou, Xiaojuan [Department of Thoracic Oncology, State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu (China); Lin, Qiang; Du, Bin [Division of Radiation Physics, State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu (China); Tian, Xue; Xu, Yong; Wang, Jin; Lu, You [Department of Thoracic Oncology, State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu (China); Gong, Youling, E-mail: gongyouling@hotmail.com [Department of Thoracic Oncology, State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu (China)

    2017-04-01

    To evaluate the lung sparing in intensity-modulated radiation therapy (IMRT) for patients with upper thoracic esophageal tumors extending inferiorly to the thorax by different beam arrangement. Overall, 15 patient cases with cancer of upper thoracic esophagus were selected for a retrospective treatment-planning study. Intensity-modulated radiation therapy plans using 4, 5, and 7 beams (4B, 5B, and 7B) were developed for each patient by direct machine parameter optimization (DMPO). All plans were evaluated with respect to dose volumes to irradiated targets and normal structures, with statistical comparisons made between 4B with 5B and 7B intensity-modulated radiation therapy plans. Differences among plans were evaluated using a two-tailed Friedman test at a statistical significance of p < 0.05. The maximum dose, average dose, and the conformity index (CI) of planning target volume 1 (PTV1) were similar for 3 plans for each case. No significant difference of coverage for planning target volume 1 and maximum dose for spinal cords were observed among 3 plans in present study (p > 0.05). The average V{sub 5}, V{sub 13}, V{sub 20}, mean lung dose, and generalized equivalent uniform dose (gEUD) for the total lung were significantly lower in 4B-plans than those data in 5B-plans and 7B-plans (p < 0.01). Although the average V{sub 30} for the total lung were significantly higher in 4B-plans than those in 5B-plans and 7B-plans (p < 0.05). In addition, when comparing with the 4B-plans, the conformity/heterogeneity index of the 5B- and 7B-plans were significantly superior (p < 0.05). The 4B-intensity-modulated radiation therapy plan has advantage to address the specialized problem of lung sparing to low- and intermediate-dose exposure in the thorax when dealing with relative long tumors extended inferiorly to the thoracic esophagus for upper esophageal carcinoma with the cost for less conformity. Studies are needed to compare the superiority of volumetric modulated arc therapy

  18. A Combined Tissue Kinetics and Dosimetric Model of Respiratory Tissue Exposed to Radiation. Final Technical Report

    International Nuclear Information System (INIS)

    John R. Ford

    2005-01-01

    Existing dosimetric models of the radiation response of tissues are essentially static. Consideration of changes in the cell populations over time has not been addressed realistically. For a single acute dose this is not a concern, but for modeling chronic exposures or fractionated acute exposures, the natural turnover and progression of cells could have a significant impact on a variety of endpoints. This proposal addresses the shortcomings of current methods by combining current dose-based calculation techniques with information on the cell turnover for a model tissue. The proposed model will examine effects at the single-cell level for an exposure of a section of human bronchiole. The cell model will be combined with Monte Carlo calculations of doses to cells and cell nuclei due to varying dose-rates of different radiation qualities. Predictions from the model of effects on survival, apoptosis rates, and changes in the number of cycling and differentiating cells will be tested experimentally. The availability of dynamic dosimetric models of tissues at the single-cell level will be useful for analysis of low-level radiation exposures and in the development of new radiotherapy protocols

  19. Characterization and standardization of a thermoluminescent dosimetric system to ultraviolet and laser radiation using CaSO4:Dy

    International Nuclear Information System (INIS)

    Grossi, Fabio Henrique

    2002-01-01

    The photo transferred thermoluminescence (PTTL) was used to characterize a dosimetric system to the laser and ultraviolet radiation. Dysprosium activated calcium sulphate samples (CaSO 4 :Dy) used are produced at Instituto de Pesquisas Energeticas e Nucleares (IPEN) and have proved been an excellent dosimetric material for non ionizing radiation. PTTL signal was studied for UV radiation detection in the 220 to 450 nm range and for laser radiation in the 193 to 1.160 nm range. The samples presented more sensibility to the 193, 250, 310 and 337 nm wavelengths and no sensibility to infrared region. The samples presented linear PTTL in function of radiant exposure, excitation gamma dose in the range between 5 and 100 Gy and laser beam diameter between 2 and 6 nm. Another parameters studied were the angular dependence, UV lower exposure limit and PTTL signal optical fading. Spread laser radiation analysis was performed in the Ophthalmologic Department of Universidade Federal de Sao Paulo (UNIFESP) surgical center, showing that samples positioned as far as 4 m from laser source are sensitized to the laser radiation, as well as evaluating the laser exposure received by workers of medical area. A method to send the samples by mail was developed to the studies performed in the UNIFESP. (author)

  20. Radiation sensitivity and EPR dosimetric potential of gallic acid and its esters

    Science.gov (United States)

    Tuner, Hasan; Oktay Bal, M.; Polat, Mustafa

    2015-02-01

    In the preset work the radiation sensitivities of Gallic Acid anhydrous and monohydrate, Octyl, Lauryl, and Ethyl Gallate (GA, GAm, OG, LG, and EG) were investigated in the intermediate (0.5-20 kGy) and low radiation (<10 Gy) dose range using Electron Paramagnetic Resonance (EPR) spectroscopy. While OG, LG, and EG are presented a singlet EPR spectra, their radiation sensitivity found to be very different in the intermediate dose range. At low radiation dose range (<10 Gy) only LG is found to be present a signal that easily distinguished from the noise signals. The intermediate and low dose range radiation sensitivities are compared using well known EPR dosimeter alanine. The radiation yields (G) of the interested material were found to be 1.34×10-2, 1.48×10-2, 4.14×10-2, and 6.03×10-2, 9.44×10-2 for EG, GA, GAm, OG, and LG, respectively at the intermediate dose range. It is found that the simple EPR spectra and the noticeable EPR signal of LG make it a promising dosimetric material to be used below 10 Gy of radiation dose.

  1. TL and OSL dosimetric properties of Opal gemstone for gamma radiation dosimetry

    International Nuclear Information System (INIS)

    Antonio, Patrícia L.; Gronchi, Claudia C.; Oliveira, Raquel A.P.; Khoury, Helen J.; Caldas, Linda V.E.

    2016-01-01

    In this work, the response of the natural material Opal was studied in relation to its thermoluminescence (TL) and optically stimulated luminescence (OSL), after exposure to the gamma radiation of a "6"0Co source. The structure of the powdered Opal was verified using the X-ray diffraction, scanning electronic microscopy and energy-dispersive X-ray spectroscopy techniques. The material, in its stone form, was turned into powder and mixed to Teflon (also in powder) in three different concentrations, and then pellets were manufactured. The aim of this work was to evaluate the response of these pellets in high-doses of gamma radiation beams, and to observe their possible application as dosimeters, using the TL and OSL techniques. The dosimetric properties of the samples were analyzed by means of different tests, as: TL emission curves and OSL signal decay curves, reproducibility of TL and OSL response, minimum detectable dose, TL and OSL dose–response curves (5 Gy–10 kGy), and fading. The results obtained in this work, for the TL and OSL phenomena, demonstrated that the pellets of Opal + Teflon present an adequate performance e possibility of use as dosimeters in beams of high-dose gamma radiation. - Highlights: • The XRD, SEM and EDX techniques were used to investigate powdered Opal. • Pellets of three different concentrations of Opal and Teflon were studied. • The dosimetric properties of the Opal + Teflon pellets were verified. • TL and OSL techniques were used to analyze the characteristics of the pellets. • Pellets of concentration of 2:1 (Opal:Teflon) presented the most adequate results.

  2. Evolution of dosimetric phantoms

    International Nuclear Information System (INIS)

    Reddy, A.R.

    2010-01-01

    In this oration evolution of the dosimetric phantoms for radiation protection and for medical use is briefly reviewed. Some details of the development of Indian Reference Phantom for internal dose estimation are also presented

  3. Discussion on concepts for radiological dosimetric quantities in the Japan Health Physics Society

    International Nuclear Information System (INIS)

    Takahashi, Fumiaki; Oda, Keiji

    2007-01-01

    Many dosimetric quantities have been used for radiation protection purpose. The International Commission on Radiological Protection (ICRP) has recommended protection quantities and the International Commission on Radiation Units and Measurements (ICRU) has introduced operational quantities to provide a reasonable estimate of the protection quantities. Enthusiastic discussions are continuously made on the issues of the dosimetric quantities, such as basic biological data for the definition of these quantities and applicability of the quantities to actual radiation protection practice. At the moment, some changes are being proposed concerning dosimetric quantities in the draft recommendations of ICRP, opened for consultation in recent years. Thus, the Japan Health Physics Society (JHPS) established the Expert Committee on concepts of Dosimetric Quantities used in radiological protection (ECDQ) in April 2005 to reviewed and discuss issues in the dosimetric quantities. (author)

  4. A treatment planning study comparing whole breast radiation therapy against conformal, IMRT and tomotherapy for accelerated partial breast irradiation

    International Nuclear Information System (INIS)

    Oliver, Mike; Chen, Jeff; Wong, Eugene; Van Dyk, Jake; Perera, Francisco

    2007-01-01

    Purpose and background: Conventional early breast cancer treatment consists of a lumpectomy followed by whole breast radiation therapy. Accelerated partial breast irradiation (APBI) is an investigational approach to post-lumpectomy radiation for early breast cancer. The purpose of this study is to compare four external beam APBI techniques, including tomotherapy, with conventional whole breast irradiation for their radiation conformity index, dose homogeneity index, and dose to organs at risk. Methods and materials: Small-field tangents, three-dimensional conformal radiation therapy, intensity-modulated radiation therapy and helical tomotherapy were compared for each of 15 patients (7 right, 8 left). One radiation conformity and two dose homogeneity indices were used to evaluate the dose to the target. The mean dose to organs at risk was also evaluated. Results: All proposed APBI techniques improved the conformity index significantly over whole breast tangents while maintaining dose homogeneity and without a significant increase in dose to organs at risk. Conclusion: The four-field IMRT plan produced the best dosimetric results; however this technique would require appropriate respiratory motion management. An alternative would be to use a four-field conformal technique that is less sensitive to the effects of respiratory motion

  5. High-Dose and Extended-Field Intensity Modulated Radiation Therapy for Early-Stage NK/T-Cell Lymphoma of Waldeyer's Ring: Dosimetric Analysis and Clinical Outcome

    Energy Technology Data Exchange (ETDEWEB)

    Bi, Xi-Wen; Li, Ye-Xiong, E-mail: yexiong@yahoo.com; Fang, Hui; Jin, Jing; Wang, Wei-Hu; Wang, Shu-Lian; Liu, Yue-Ping; Song, Yong-Wen; Ren, Hua; Dai, Jian-Rong

    2013-12-01

    Purpose: To assess the dosimetric benefit, treatment outcome, and toxicity of high-dose and extended-field intensity modulated radiation therapy (IMRT) in patients with early-stage NK/T-cell lymphoma of Waldeyer's ring (WR-NKTCL). Methods and Materials: Thirty patients with early-stage WR-NKTCL who received extended-field IMRT were retrospectively reviewed. The prescribed dose was 50 Gy to the primary involved regions and positive cervical lymph nodes (planning target volume requiring radical irradiation [PTV{sub 50}]) and 40 Gy to the negative cervical nodes (PTV{sub 40}). Dosimetric parameters for the target volume and critical normal structures were evaluated. Locoregional control (LRC), overall survival (OS), and progression-free survival (PFS) were calculated using the Kaplan-Meier method. Results: The median mean doses to the PTV{sub 50} and PTV{sub 40} were 53.2 Gy and 43.0 Gy, respectively. Only 1.4% of the PTV{sub 50} and 0.9% of the PTV{sub 40} received less than 95% of the prescribed dose, indicating excellent target coverage. The average mean doses to the left and right parotid glands were 27.7 and 28.4 Gy, respectively. The 2-year OS, PFS, and LRC rates were 71.2%, 57.4%, and 87.8%. Most acute toxicities were grade 1 to 2, except for grade ≥3 dysphagia and mucositis. The most common late toxicity was grade 1-2 xerostomia, and no patient developed any ≥grade 3 late toxicities. A correlation between the mean dose to the parotid glands and the degree of late xerostomia was observed. Conclusions: IMRT achieves excellent target coverage and dose conformity, as well as favorable survival and locoregional control rates with acceptable toxicities in patients with WR-NKTCL.

  6. SU-F-BRB-15: Dosimetric Study of Radiation Therapy for Head/Neck Patients with Metallic Dental Fixtures

    Energy Technology Data Exchange (ETDEWEB)

    Lu, L; Allan, E; Putten, M Van; Gupta, N; Blakaj, D [OH State University, Columbus, OH (United States)

    2015-06-15

    Purpose: To investigate the dose contributions of scattered electrons from dental amalgams during head and neck radiotherapy, and to evaluate the protective role of dosimetric dental stents during treatment to prevent oral mucositis. Methods: A phantom was produced to accurately simulate the oral cavity and head. The oral cavity consisted of a tissue equivalent upper and lower jaw and complete set of teeth. A set of 4 mm ethylene copolymer dosimetric stents was made for the upper and lower teeth. Five removable gold caps were fitted to apposing right molars, and the phantom was crafted to accomodate horizontal and vertical film for 2D dosimetry and NanoDot dosimeter for recording point doses. The head was simulated using a small cylindrical glass water bath. CT simulation was performed on the phantom with and without metal fittings and, in each case, with and without the dental stent. The CT image sets were imported into Eclipse treatment planning system for contouring and treatment planning, and a 9-field IMRT treatment plan was developed for each scenario. These plans were delivered using a Varian TrueBeam linear accelerator. Doses were recorded using GafChromic EBT2 films and NanoDot dosimeters. Results: The measurements revealed a 43% relative increase in dose measured adjacent to the metal fixtures in the horizontal plane without the use of the dental stent. This equates to a total dose of 100 Gy to the oral mucosa during a standard course of definitive radiotherapy. To our knowledge, this is the first dosimetric analysis of dental stents using an anatomically realistic phantom and modern beam arrangement. Conclusion: These results support the use of dosimetric dental stents in head and neck radiotherapy for patients with metallic dental fixtures as a way to effectively reduce dose to nearby mucosal surfaces and, hence, reduce the risk and severity of mucositis.

  7. SU-F-BRB-15: Dosimetric Study of Radiation Therapy for Head/Neck Patients with Metallic Dental Fixtures

    International Nuclear Information System (INIS)

    Lu, L; Allan, E; Putten, M Van; Gupta, N; Blakaj, D

    2015-01-01

    Purpose: To investigate the dose contributions of scattered electrons from dental amalgams during head and neck radiotherapy, and to evaluate the protective role of dosimetric dental stents during treatment to prevent oral mucositis. Methods: A phantom was produced to accurately simulate the oral cavity and head. The oral cavity consisted of a tissue equivalent upper and lower jaw and complete set of teeth. A set of 4 mm ethylene copolymer dosimetric stents was made for the upper and lower teeth. Five removable gold caps were fitted to apposing right molars, and the phantom was crafted to accomodate horizontal and vertical film for 2D dosimetry and NanoDot dosimeter for recording point doses. The head was simulated using a small cylindrical glass water bath. CT simulation was performed on the phantom with and without metal fittings and, in each case, with and without the dental stent. The CT image sets were imported into Eclipse treatment planning system for contouring and treatment planning, and a 9-field IMRT treatment plan was developed for each scenario. These plans were delivered using a Varian TrueBeam linear accelerator. Doses were recorded using GafChromic EBT2 films and NanoDot dosimeters. Results: The measurements revealed a 43% relative increase in dose measured adjacent to the metal fixtures in the horizontal plane without the use of the dental stent. This equates to a total dose of 100 Gy to the oral mucosa during a standard course of definitive radiotherapy. To our knowledge, this is the first dosimetric analysis of dental stents using an anatomically realistic phantom and modern beam arrangement. Conclusion: These results support the use of dosimetric dental stents in head and neck radiotherapy for patients with metallic dental fixtures as a way to effectively reduce dose to nearby mucosal surfaces and, hence, reduce the risk and severity of mucositis

  8. Hendee's radiation therapy physics

    CERN Document Server

    Pawlicki, Todd; Starkschall, George

    2016-01-01

    The publication of this fourth edition, more than ten years on from the publication of Radiation Therapy Physics third edition, provides a comprehensive and valuable update to the educational offerings in this field. Led by a new team of highly esteemed authors, building on Dr Hendee’s tradition, Hendee’s Radiation Therapy Physics offers a succinctly written, fully modernised update. Radiation physics has undergone many changes in the past ten years: intensity-modulated radiation therapy (IMRT) has become a routine method of radiation treatment delivery, digital imaging has replaced film-screen imaging for localization and verification, image-guided radiation therapy (IGRT) is frequently used, in many centers proton therapy has become a viable mode of radiation therapy, new approaches have been introduced to radiation therapy quality assurance and safety that focus more on process analysis rather than specific performance testing, and the explosion in patient-and machine-related data has necessitated an ...

  9. Intensity-modulated radiation therapy to bilateral lower limb extremities concurrently: a planning case study

    Energy Technology Data Exchange (ETDEWEB)

    Fitzgerald, Emma, E-mail: emmafitz1390@gmail.com; Miles, Wesley; Fenton, Paul; Frantzis, Jim [Radiation Oncology, Epworth HealthCare, Victoria (Australia)

    2014-09-15

    Non-melanomatous skin cancers represent 80% of all newly diagnosed cancers in Australia with basal cell carcinoma (BCC) and squamous cell carcinoma (SCC) being the most common. A previously healthy 71-year-old woman presented with widespread and tender superficial skin cancers on the lower bilateral limbs. External beam radiation therapy through the use of intensity-modulated radiation therapy (IMRT) was employed as the treatment modality of choice as this technique provides conformal dose distribution to a three-dimensional treatment volume while reducing toxicity to surrounding tissues. The patient was prescribed a dose of 60 Gy to the planning target volume (PTV) with 1.0 cm bolus over the ventral surface of each limb. The beam arrangement consisted of six treatment fields that avoided entry and exit through the contralateral limb. The treatment plans met the International Commission on Radiation Units and Measurements (ICRU) guidelines and produced highly conformal dosimetric results. Skin toxicity was measured against the National Cancer Institute: Common Terminology Criteria for Adverse Events (NCI: CTCAE) version 3. A well-tolerated treatment was delivered with excellent results given the initial extent of the disease. This case study has demonstrated the feasibility and effectiveness of IMRT for skin cancers as an alternative to surgery and traditional superficial radiation therapy, utilising a complex PTV of the extremities for patients with similar presentations.

  10. Predictors of Hypothyroidism in Hodgkin Lymphoma Survivors After Intensity Modulated Versus 3-Dimensional Radiation Therapy.

    Science.gov (United States)

    Pinnix, Chelsea C; Cella, Laura; Andraos, Therese Y; Ayoub, Zeina; Milgrom, Sarah A; Gunther, Jillian; Thosani, Sonali; Wogan, Christine; Conson, Manuel; D'Avino, Vittoria; Oki, Yasuhiro; Fanale, Michelle; Lee, Hun J; Neelapu, Sattva; Fayad, Luis; Hagemeister, Frederick; Rodriguez, M Alma; Nastoupil, Loretta J; Nieto, Yago; Qiao, Wei; Pacelli, Roberto; Dabaja, Bouthaina

    2018-03-14

    To identify predictors of hypothyroidism after chemoradiation therapy for Hodgkin lymphoma (HL) and to compare outcomes after intensity modulated radiation therapy (IMRT) with those after 3-dimensional (3D) conformal radiation therapy (CRT). Ninety patients who underwent involved-site IMRT in 2009 through 2014 were evaluated for treatment-induced hypothyroidism, defined as elevated thyroid-stimulating hormone or decreased free thyroxine levels (or both). Receiver operating characteristic curve analysis identified individuals at low versus high risk based on dosimetric variables. Dosimetric cutoff points were verified with an external data set of 50 patients who underwent 3D-CRT. In the IMRT group, most patients (75 [83%]) had stage II HL, and the median prescribed dose was 30.6 Gy; in the 3D-CRT group, 32 patients (64%) had stage II HL, and the median prescribed dose was 32.0 Gy. No differences were found in the proportions of patients with bilateral (P = .982) or unilateral (P = .074) neck involvement between the 2 groups. Hypothyroidism rates were marginally higher in the IMRT group, with estimated 3-year rates of freedom from hypothyroidism of 56.1% in the 3D-CRT group and 40% in the IMRT group (P = .057). Univariate analysis showed that smaller thyroid volume and higher thyroid dose were associated with hypothyroidism in both groups (P hypothyroidism (P = .001 and P hypothyroidism (P hypothyroidism after either IMRT or 3D-CRT for HL. IMRT may confer a higher risk than 3D-CRT unless a treatment avoidance structure is used during planning. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Study of a new dosimetric radio-thermoluminescent systems

    International Nuclear Information System (INIS)

    Cazac, T.C.

    1980-01-01

    This is the first Romanian study to investigate conditions to obtain the radio-thermo-luminescent systems: MgB 4 O 7 :A(A-Nd,Sm,Eu,Dy,Tb,Dy+Sm and Tb+Sm) MgF 2 A (A=Mn,Dy,Tb,Sm,Li), their essential dosimetric characters, as well as the (MgF 2 =Mn) thermophosphorus mixture with a ( 6 LiF) lithium target. An investigation was developed upon a new category of radio-thermoluminescent detectors with low radiation energy dependence and fading, magnesjum boride activated by several elements of the lanthanides class (Nd,Sm,Eu,Dy,Tb). A new radio-thermoluminescent dosimetric system with high sensitivity and moderate dependence on energy radiation - (Mnsup(2+)) manganese activated magnesium fluoride - was also studied. The author explored application of investigated detectors MgF 2 =Mn, MgB 4 O 7 =Dy and MgB 4 O 7 :Tb in neutron dosimetry in complex gamma-neutron fields. It is deemed that by using the dosimetric systems reported in the thesis in order to measure gamma, beta and neutron radiation doses, dosimetric control can be ensured both in professional dosimetry and in nuclear accident dosimetry, as well as in various basic and applicative investigations. A modest contribution is thus made towards achieving the national nuclear program through an extension of the thermophosphorus range with practical applications in nuclear radiation dosimetry. (author)

  12. Effect of stereotactic dosimetric end points on overall survival for Stage I non–small cell lung cancer: A critical review

    Energy Technology Data Exchange (ETDEWEB)

    Mulryan, Kathryn; Leech, Michelle; Forde, Elizabeth, E-mail: eforde@tcd.ie

    2015-01-01

    Stereotactic body radiation therapy (SBRT) delivers a high biologically effective dose while minimizing toxicities to surrounding tissues. Within the scope of clinical trials and local practice, there are inconsistencies in dosimetrics used to evaluate plan quality. The purpose of this critical review was to determine if dosimetric parameters used in SBRT plans have an effect on local control (LC), overall survival (OS), and toxicities. A database of relevant trials investigating SBRT for patients with early-stage non–small cell lung cancer was compiled, and a table of dosimetric variables used was created. These parameters were compared and contrasted for LC, OS, and toxicities. Dosimetric end points appear to have no effect on OS or LC. Incidences of rib fractures correlate with a lack of dose-volume constraints (DVCs) reported. This review highlights the great disparity present in clinical trials reporting dosimetrics, DVCs, and toxicities for lung SBRT. Further evidence is required before standard DVCs guidelines can be introduced. Dosimetric end points specific to stereotactic treatment planning have been proposed but require further investigation before clinical implementation.

  13. TL and LOE dosimetric evaluation of diamond films exposed to beta and ultraviolet radiation

    International Nuclear Information System (INIS)

    Preciado F, S.; Melendrez, R.; Chernov, V.; Barboza F, M.; Schreck, M.; Cruz Z, E.

    2005-01-01

    The diamond possesses a privileged position regarding other materials of great technological importance. Their applications go from the optics, microelectronics, metals industry, medicine and of course as dosemeter, in the registration and detection of ionizing and non ionizing radiation. In this work the results of TL/LOE obtained in two samples of diamond of 10 μm thickness grown by the chemical vapor deposition method (CVD) assisted by microwave plasma. The films were deposited in a silicon substrate (001) starting from a mixture of gases composed of CH 4 /H 2 and 750 ppm of molecular nitrogen as dopant. The samples were exposed to beta radiation (Sr 90 / Y 90 ) and ultraviolet, being stimulated later on thermal (TL) and optically (LOE) to evaluate their dosimetric properties. The sample without doping presented high response TL/LOE to the ultraviolet and beta radiation. The TL glow curve of the sample without doping showed two TL peaks with second order kinetics in the range of 520 to 550 K, besides a peak with first order kinetics of more intensity around 607 K. The TL efficiency of the non doped sample is bigger than the doped with nitrogen; however the LOE efficiency is similar in both samples. The results indicate that the CVD diamond possesses excellent perspectives for dosimetric applications, with special importance in radiotherapy due to it is biologically compatible with the human tissue. (Author)

  14. Operational guidance for radiation emergency response organisations in Europe for using bio-dosimetric tools developed in EU MULTIBIODOSE project

    International Nuclear Information System (INIS)

    Jaworska, Alicja; Ainsbury, Elizabeth A.; Rothkamm, Kai; Fattibene, Paola; Lindholm, Carita; Oestreicher, Ursula; Romm, Horst; Thierens, Hubert; Vral, Anne; Trompier, Francois; Voisin, Philippe; Woda, Clemens; Wojcik, Andrzej

    2015-01-01

    In the event of a large-scale radiological emergency, the triage of individuals according to their degree of exposure forms an important initial step of the accident management. Although clinical signs and symptoms of a serious exposure may be used for radiological triage, they are not necessarily radiation specific and can lead to a false diagnosis. Biodosimetry is a method based on the analysis of radiation-induced changes in cells of the human body or in portable electronic devices and enables the unequivocal identification of exposed people who should receive medical treatment. The MULTIBIODOSE (MBD) consortium developed and validated several bio-dosimetric assays and adapted and tested them as tools for biological dose assessment in a mass-casualty event. Different bio-dosimetric assays were validated against the 'gold standard' of biological dosimetry-the dicentric assay. The assays were harmonised in such a way that, in an emergency situation, they can be run in parallel in a network of European laboratories. The aim of this guidance is to give a concise overview of the developed bio-dosimetric tools as well as how and when they can be used in an emergency situation. (authors)

  15. Film Dosimetry for Intensity Modulated Radiation Therapy

    International Nuclear Information System (INIS)

    Benites-Rengifo, J.; Martinez-Davalos, A.; Celis, M.; Larraga, J.

    2004-01-01

    Intensity Modulated Radiation Therapy (IMRT) is an oncology treatment technique that employs non-uniform beam intensities to deliver highly conformal radiation to the targets while minimizing doses to normal tissues and critical organs. A key element for a successful clinical implementation of IMRT is establishing a dosimetric verification process that can ensure that delivered doses are consistent with calculated ones for each patient. To this end we are developing a fast quality control procedure, based on film dosimetry techniques, to be applied to the 6 MV Novalis linear accelerator for IMRT of the Instituto Nacional de Neurologia y Neurocirugia (INNN) in Mexico City. The procedure includes measurements of individual fluence maps for a limited number of fields and dose distributions in 3D using extended dose-range radiographic film. However, the film response to radiation might depend on depth, energy and field size, and therefore compromise the accuracy of measurements. In this work we present a study of the dependence of Kodak EDR2 film's response on the depth, field size and energy, compared with those of Kodak XV2 film. The first aim is to devise a fast and accurate method to determine the calibration curve of film (optical density vs. doses) commonly called a sensitometric curve. This was accomplished by using three types of irradiation techniques: Step-and-shoot, dynamic and static fields

  16. Late rectal sequelae following definitive radiation therapy for carcinoma of the uterine cervix: a dosimetric analysis

    International Nuclear Information System (INIS)

    Roeske, John C.; Mundt, Arno J.; Halpern, Howard; Sweeney, Patrick; Sutton, Harold; Powers, Claire; Rotmensch, Jacob; Waggoner, Steve; Weichselbaum, Ralph R.

    1997-01-01

    Purpose: This study attempted to correlate patient, treatment, and dosimetric factors with the risk of late rectal sequelae in patients treated with radiation therapy (RT) for cervical carcinoma. Methods and Materials: A total of 183 patients with cervical carcinoma (67 Stage I, 93 Stage II, and 23 Stage III) treated with definitive RT with a minimum of 2 years follow-up were evaluated. Treatment consisted of external beam pelvic RT (EBRT) followed by intracavitary RT (ICRT) consisting of one or two insertions. Complications were scored and analyzed as a function of 25 patient and treatment factors. Conventional total rectal doses were obtained by adding together the EBRT and ICRT rectal doses. To account for differences in dose rate between the ICRT and EBRT, and variations in EBRT fractionation schemes, biologically equivalent rectal doses (BED) were calculated using a linear quadratic model. In addition, the influence of the varying proportions of EBRT and ICRT rectal doses were evaluated. Results: Twenty-eight patients (15.3%) developed late rectal sequelae (13 Grade 1, 3 Grade 2, and 12 Grade 3). Diabetes (p = 0.03), Point A dose (p = 0.04), and conventional EBRT dose (p = 0.03) were the most significant factors on multivariate analysis. Logistic regression analysis demonstrated a low risk (<10%) of late rectal sequelae below conventional and biological rectal doses of 75 Gy and 135 BED, respectively. The percentage of rectal dose delivered by the EBRT significantly influenced the dose-response relationship. A defined threshold percentage above which rectal sequelae were more common was identified over the range of doses evaluated. This threshold was 87% at a total rectal dose of 60 Gy and decreased to 60% at 80 Gy. Conclusion: Diabetes, Point A, and EBRT doses are the most significant factors associated with the risk of late rectal sequelae in patients treated with RT for cervical carcinoma. The percentage of rectal dose delivered by the EBRT significantly

  17. Risk management of radiation therapy. Survey by north Japan radiation therapy oncology group

    International Nuclear Information System (INIS)

    Aoki, Masahiko; Abe, Yoshinao; Yamada, Shogo; Hareyama, Masato; Nakamura, Ryuji; Sugita, Tadashi; Miyano, Takashi

    2004-01-01

    A North Japan Radiation Oncology Group (NJRTOG) survey was carried out to disclose the risk management of radiation therapy. During April 2002, we sent questionnaires to radiation therapy facilities in northern Japan. There were 31 replies from 27 facilities. Many incidents and accidents were reported, including old cases. Although 60% of facilities had a risk management manual and/or risk manager, only 20% had risk management manuals for radiation therapy. Eighty five percent of radiation oncologists thought that incidents may be due to a lack of manpower. Ninety percent of radiation oncologists want to know the type of cases happened in other facilities. The risk management system is still insufficient for radiation therapy. We hope that our data will be a great help to develop risk management strategies for radiation therapy for all radiation oncologists in Japan. (author)

  18. Development of a daily dosimetric control for radiation therapy using an electronic portal imaging device (EPID)

    International Nuclear Information System (INIS)

    Saboori, Mohammadsaeed

    2015-01-01

    Electronic Portal Imaging Devices (EPIDs) can be used to perform dose measurements during radiation therapy treatments if dedicated calibration and correction procedures are applied. The purpose of this study was to provide a new calibration and correction model for an amorphous silicon (a-Si) EPID for use in transit dose verification of step-and-shoot intensity modulated radiation therapy (IMRT). A model was created in a commercial treatment planning system to calculate the nominal two-dimensional (2D) dose map of each radiation field at the EPID level. The EPID system was calibrated and correction factors were determined using a reference set-up, which consisted a patient phantom and an EPID phantom. The advantage of this method is that for the calibration, the actual beam spectrum is used to mimic a patient measurement. As proof-of-principle, the method was tested for the verification of two 7-field IMRT treatment plans with tumor sites in the head-and-neck and pelvic region. Predicted and measured EPID responses were successfully compared to the nominal data from treatment planning using dose difference maps and gamma analyses. Based on our result it can be concluded that this new method of 2D EPID dosimetry is a potential tool for simple patient treatment fraction dose verification.

  19. Hypofractionated Whole-Breast Radiation Therapy: Does Breast Size Matter?

    Energy Technology Data Exchange (ETDEWEB)

    Hannan, Raquibul, E-mail: Raquibul.Hannan@gmail.com [Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Thompson, Reid F.; Chen Yu; Bernstein, Karen; Kabarriti, Rafi; Skinner, William [Department of Radiation Oncology, Albert Einstein College of Medicine, Montefiore Medical Center, Bronx, New York (United States); Chen, Chin C. [Department of Radiation Oncology, Columbia University Medical Center, New York, New York (United States); Landau, Evan; Miller, Ekeni; Spierer, Marnee; Hong, Linda; Kalnicki, Shalom [Department of Radiation Oncology, Albert Einstein College of Medicine, Montefiore Medical Center, Bronx, New York (United States)

    2012-11-15

    Purpose: To evaluate the effects of breast size on dose-volume histogram parameters and clinical toxicity in whole-breast hypofractionated radiation therapy using intensity modulated radiation therapy (IMRT). Materials and Methods: In this retrospective study, all patients undergoing breast-conserving therapy between 2005 and 2009 were screened, and qualifying consecutive patients were included in 1 of 2 cohorts: large-breasted patients (chest wall separation >25 cm or planning target volume [PTV] >1500 cm{sub 3}) (n=97) and small-breasted patients (chest wall separation <25 cm and PTV <1500 cm{sub 3}) (n=32). All patients were treated prone or supine with hypofractionated IMRT to the whole breast (42.4 Gy in 16 fractions) followed by a boost dose (9.6 Gy in 4 fractions). Dosimetric and clinical toxicity data were collected and analyzed using the R statistical package (version 2.12). Results: The mean PTV V95 (percentage of volume receiving >= 95% of prescribed dose) was 90.18% and the mean V105 percentage of volume receiving >= 105% of prescribed dose was 3.55% with no dose greater than 107%. PTV dose was independent of breast size, whereas heart dose and maximum point dose to skin correlated with increasing breast size. Lung dose was markedly decreased in prone compared with supine treatments. Radiation Therapy Oncology Group grade 0, 1, and 2 skin toxicities were noted acutely in 6%, 69%, and 25% of patients, respectively, and at later follow-up (>3 months) in 43%, 57%, and 0% of patients, respectively. Large breast size contributed to increased acute grade 2 toxicity (28% vs 12%, P=.008). Conclusions: Adequate PTV coverage with acceptable hot spots and excellent sparing of organs at risk was achieved by use of IMRT regardless of treatment position and breast size. Although increasing breast size leads to increased heart dose and maximum skin dose, heart dose remained within our institutional constraints and the incidence of overall skin toxicity was comparable

  20. Legal verification of the dosimetric instrumentation using for radiation protection in Cuba

    International Nuclear Information System (INIS)

    Walwyn, A.; Morales, J.A.

    1999-01-01

    By April of 1998 the Decree law 183 of Metrology was published at the Gaceta Oficial de la Republica de Cuba. It establishes the principles and general regulations for the organisation and juridical system of the metrological activity in Cuba. In the radiation protection field this legislation promote the establishment of a verification service of radiation measuring instruments used in the practices with radiation sources in the country. The limitations of old Cuban standards of verification related to dosimetric quantities and to the types of instruments for those which these standards are applicable; and in addition, the publication of new international standards that includes the operational quantities used for the measurement of instruments, led to the elaboration of the X and Gamma Radiation Meters Used in Radiation Protection standard. The requirements of metrological aptitude are taken from some test procedures described in the International Electrotechnical Commission (IEC) standards on photon monitoring equipment. The Secondary Standard Dosimetry Laboratory of the Centre for Radiation Protection and Higiene will start the verification service of Radiation Protection instruments. The beginning of the service is an essential element in the improvement of the accuracy of ionisation radiation metrology in Cuba, and have an evident impact in the protection of the occupationally exposed workers, because having the instruments in good technical condition became a legal exigency to the users of ionisation radiation

  1. Selective internal radiation therapy (SIRT) for liver metastases secondary to colorectal adenocarcinoma

    International Nuclear Information System (INIS)

    Welsh, James S.; Kennedy, Andrew S.; Thomadsen, Bruce

    2006-01-01

    Introduction: Selective internal radiation therapy (SIRT) is a relatively new commercially available microbrachytherapy technique for treatment of malignant hepatic lesions using 9 Y embedded in resin microspheres, which are infused directly into the hepatic arterial circulation. It is FDA approved for liver metastases secondary to colorectal carcinoma and is under investigation for treatment of other liver malignancies, such as hepatocellular carcinoma and neuroendocrine malignancies. Materials/Methods: A modest number of clinical trials, preclinical animal studies, and dosimetric studies have been reported. Here we review several of the more important results. Results: High doses of beta radiation can be selectively delivered to tumors, resulting in impressive local control and survival rates. Ex vivo analyses have shown that microspheres preferentially cluster around the periphery of tumor nodules with a high tumor:normal tissue ratio of up to 200:1. Toxicity is usually mild, featuring fatigue, anorexia, nausea, abdominal discomfort, and slight elevations of liver function tests. Conclusions: Selective internal radiation therapy represents an effective means of controlling liver metastases from colorectal adenocarcinoma. Clinical trials have demonstrated improved local control of disease and survival with relatively low toxicity. Investigations of SIRT for other hepatic malignancies and in combination with newer chemotherapy agents and targeted biologic therapies are under way or in planning. A well-integrated team involving interventional radiology, nuclear medicine, medical oncology, surgical oncology, medical physics, and radiation oncology is essential for a successful program. Careful selection of patients through the combined expertise of the team can maximize therapeutic efficacy and reduce the potential for adverse effects

  2. Hot pixel generation in active pixel sensors: dosimetric and micro-dosimetric response

    Science.gov (United States)

    Scheick, Leif; Novak, Frank

    2003-01-01

    The dosimetric response of an active pixel sensor is analyzed. heavy ions are seen to damage the pixel in much the same way as gamma radiation. The probability of a hot pixel is seen to exhibit behavior that is not typical with other microdose effects.

  3. Normal tissue tolerance to external beam radiation therapy: Esophagus

    International Nuclear Information System (INIS)

    Bera, G.; Pointreau, Y.; Denis, F.; Dupuis, O.; Orain, I.; Crehange, G.

    2010-01-01

    The esophagus is a musculo-membranous tube through which food passes from the pharynx to the stomach. Due to its anatomical location, it can be exposed to ionizing radiation in many external radiotherapy indications. Radiation-induced esophageal mucositis is clinically revealed by dysphagia and odynophagia, and usually begins 3 to 4 weeks after the start of radiation treatment. With the rise of multimodality treatments (e.g., concurrent chemoradiotherapy, dose escalation and accelerated fractionation schemes), esophageal toxicity has become a significant dose-limiting issue. Understanding the predictive factors of esophageal injury may improve the optimal delivery of treatment plans. It may help to minimize the risks, hence increasing the therapeutic ratio. Based on a large literature review, our study describes both early and late radiation-induced esophageal injuries and highlights some of the predictive factors for cervical and thoracic esophagus toxicity. These clinical and dosimetric parameters are numerous but none is consensual. The large number of dosimetric parameters strengthens the need of an overall analysis of the dose/volume histograms. The data provided is insufficient to recommend their routine use to prevent radiation-induced esophagitis. Defining guidelines for the tolerance of the esophagus to ionizing radiation remains essential for a safe and efficient treatment. (authors)

  4. Forward-planned intensity modulated radiation therapy using a cobalt source: A dosimetric study in breast cancer

    Directory of Open Access Journals (Sweden)

    Savino Cilla

    2013-01-01

    Full Text Available This analysis evaluates the feasibility and dosimetric results of a simplified intensity-modulated radiotherapy (IMRT treatment using a cobalt-therapy unit for post-operative breast cancer. Fourteen patients were included. Three plans per patient were produced by a cobalt-60 source: A standard plan with two wedged tangential beams, a standard tangential plan optimized without the use of wedges and a plan based on the forward-planned "field-in-field" IMRT technique (Co-FinF where the dose on each of the two tangential beams was split into two different segments and the two segments weight was determined with an iterative process. For comparison purposes, a 6-MV photon standard wedged tangential treatment plan was generated. D mean , D 98% , D 2% , V 95% , V 107%, homogeneity, and conformity indices were chosen as parameters for comparison. Co-FinF technique improved the planning target volume dose homogeneity compared to other cobalt-based techniques and reduced maximum doses (D 2% and high-dose volume (V 110% . Moreover, it showed a better lung and heart dose sparing with respect to the standard approach. The higher dose homogeneity may encourage the adoption of accelerated-hypofractionated treatments also with the cobalt sources. This approach can promote the spread of breast conservative treatment in developing countries.

  5. Radiation Dose to the Esophagus From Breast Cancer Radiation Therapy, 1943-1996: An International Population-Based Study of 414 Patients

    International Nuclear Information System (INIS)

    Lamart, Stephanie; Stovall, Marilyn; Simon, Steven L.; Smith, Susan A.; Weathers, Rita E.; Howell, Rebecca M.; Curtis, Rochelle E.; Aleman, Berthe M.P.; Travis, Lois; Kwon, Deukwoo; Morton, Lindsay M.

    2013-01-01

    Purpose: To provide dosimetric data for an epidemiologic study on the risk of second primary esophageal cancer among breast cancer survivors, by reconstructing the radiation dose incidentally delivered to the esophagus of 414 women treated with radiation therapy for breast cancer during 1943-1996 in North America and Europe. Methods and Materials: We abstracted the radiation therapy treatment parameters from each patient’s radiation therapy record. Treatment fields included direct chest wall (37% of patients), medial and lateral tangentials (45%), supraclavicular (SCV, 64%), internal mammary (IM, 44%), SCV and IM together (16%), axillary (52%), and breast/chest wall boosts (7%). The beam types used were 60 Co (45% of fields), orthovoltage (33%), megavoltage photons (11%), and electrons (10%). The population median prescribed dose to the target volume ranged from 21 Gy to 40 Gy. We reconstructed the doses over the length of the esophagus using abstracted patient data, water phantom measurements, and a computational model of the human body. Results: Fields that treated the SCV and/or IM lymph nodes were used for 85% of the patients and delivered the highest doses within 3 regions of the esophagus: cervical (population median 38 Gy), upper thoracic (32 Gy), and middle thoracic (25 Gy). Other fields (direct chest wall, tangential, and axillary) contributed substantially lower doses (approximately 2 Gy). The cervical to middle thoracic esophagus received the highest dose because of its close proximity to the SCV and IM fields and less overlying tissue in that part of the chest. The location of the SCV field border relative to the midline was one of the most important determinants of the dose to the esophagus. Conclusions: Breast cancer patients in this study received relatively high incidental radiation therapy doses to the esophagus when the SCV and/or IM lymph nodes were treated, whereas direct chest wall, tangentials, and axillary fields contributed lower doses

  6. Radiation dose to the esophagus from breast cancer radiation therapy, 1943-1996: an international population-based study of 414 patients.

    Science.gov (United States)

    Lamart, Stephanie; Stovall, Marilyn; Simon, Steven L; Smith, Susan A; Weathers, Rita E; Howell, Rebecca M; Curtis, Rochelle E; Aleman, Berthe M P; Travis, Lois; Kwon, Deukwoo; Morton, Lindsay M

    2013-07-15

    To provide dosimetric data for an epidemiologic study on the risk of second primary esophageal cancer among breast cancer survivors, by reconstructing the radiation dose incidentally delivered to the esophagus of 414 women treated with radiation therapy for breast cancer during 1943-1996 in North America and Europe. We abstracted the radiation therapy treatment parameters from each patient's radiation therapy record. Treatment fields included direct chest wall (37% of patients), medial and lateral tangentials (45%), supraclavicular (SCV, 64%), internal mammary (IM, 44%), SCV and IM together (16%), axillary (52%), and breast/chest wall boosts (7%). The beam types used were (60)Co (45% of fields), orthovoltage (33%), megavoltage photons (11%), and electrons (10%). The population median prescribed dose to the target volume ranged from 21 Gy to 40 Gy. We reconstructed the doses over the length of the esophagus using abstracted patient data, water phantom measurements, and a computational model of the human body. Fields that treated the SCV and/or IM lymph nodes were used for 85% of the patients and delivered the highest doses within 3 regions of the esophagus: cervical (population median 38 Gy), upper thoracic (32 Gy), and middle thoracic (25 Gy). Other fields (direct chest wall, tangential, and axillary) contributed substantially lower doses (approximately 2 Gy). The cervical to middle thoracic esophagus received the highest dose because of its close proximity to the SCV and IM fields and less overlying tissue in that part of the chest. The location of the SCV field border relative to the midline was one of the most important determinants of the dose to the esophagus. Breast cancer patients in this study received relatively high incidental radiation therapy doses to the esophagus when the SCV and/or IM lymph nodes were treated, whereas direct chest wall, tangentials, and axillary fields contributed lower doses. Published by Elsevier Inc.

  7. Radiation Dose to the Esophagus From Breast Cancer Radiation Therapy, 1943-1996: An International Population-Based Study of 414 Patients

    Energy Technology Data Exchange (ETDEWEB)

    Lamart, Stephanie, E-mail: stephanie.lamart@nih.gov [Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Bethesda, Maryland (United States); Stovall, Marilyn [Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Simon, Steven L. [Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Bethesda, Maryland (United States); Smith, Susan A.; Weathers, Rita E.; Howell, Rebecca M. [Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Curtis, Rochelle E. [Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Bethesda, Maryland (United States); Aleman, Berthe M.P. [Department of Radiotherapy, The Netherlands Cancer Institute, Amsterdam (Netherlands); Travis, Lois [Rubin Center for Cancer Survivorship and Department of Radiation Oncology, University of Rochester Medical Center, Rochester, New York (United States); Kwon, Deukwoo [Sylvester Comprehensive Cancer Center, University of Miami, Miami, Florida (United States); Morton, Lindsay M. [Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Bethesda, Maryland (United States)

    2013-07-15

    Purpose: To provide dosimetric data for an epidemiologic study on the risk of second primary esophageal cancer among breast cancer survivors, by reconstructing the radiation dose incidentally delivered to the esophagus of 414 women treated with radiation therapy for breast cancer during 1943-1996 in North America and Europe. Methods and Materials: We abstracted the radiation therapy treatment parameters from each patient’s radiation therapy record. Treatment fields included direct chest wall (37% of patients), medial and lateral tangentials (45%), supraclavicular (SCV, 64%), internal mammary (IM, 44%), SCV and IM together (16%), axillary (52%), and breast/chest wall boosts (7%). The beam types used were {sup 60}Co (45% of fields), orthovoltage (33%), megavoltage photons (11%), and electrons (10%). The population median prescribed dose to the target volume ranged from 21 Gy to 40 Gy. We reconstructed the doses over the length of the esophagus using abstracted patient data, water phantom measurements, and a computational model of the human body. Results: Fields that treated the SCV and/or IM lymph nodes were used for 85% of the patients and delivered the highest doses within 3 regions of the esophagus: cervical (population median 38 Gy), upper thoracic (32 Gy), and middle thoracic (25 Gy). Other fields (direct chest wall, tangential, and axillary) contributed substantially lower doses (approximately 2 Gy). The cervical to middle thoracic esophagus received the highest dose because of its close proximity to the SCV and IM fields and less overlying tissue in that part of the chest. The location of the SCV field border relative to the midline was one of the most important determinants of the dose to the esophagus. Conclusions: Breast cancer patients in this study received relatively high incidental radiation therapy doses to the esophagus when the SCV and/or IM lymph nodes were treated, whereas direct chest wall, tangentials, and axillary fields contributed lower

  8. Accuracy of Real-time Couch Tracking During 3-dimensional Conformal Radiation Therapy, Intensity Modulated Radiation Therapy, and Volumetric Modulated Arc Therapy for Prostate Cancer

    International Nuclear Information System (INIS)

    Wilbert, Juergen; Baier, Kurt; Hermann, Christian; Flentje, Michael; Guckenberger, Matthias

    2013-01-01

    Purpose: To evaluate the accuracy of real-time couch tracking for prostate cancer. Methods and Materials: Intrafractional motion trajectories of 15 prostate cancer patients were the basis for this phantom study; prostate motion had been monitored with the Calypso System. An industrial robot moved a phantom along these trajectories, motion was detected via an infrared camera system, and the robotic HexaPOD couch was used for real-time counter-steering. Residual phantom motion during real-time tracking was measured with the infrared camera system. Film dosimetry was performed during delivery of 3-dimensional conformal radiation therapy (3D-CRT), step-and-shoot intensity modulated radiation therapy (IMRT), and volumetric modulated arc therapy (VMAT). Results: Motion of the prostate was largest in the anterior–posterior direction, with systematic (∑) and random (σ) errors of 2.3 mm and 2.9 mm, respectively; the prostate was outside a threshold of 5 mm (3D vector) for 25.0%±19.8% of treatment time. Real-time tracking reduced prostate motion to ∑=0.01 mm and σ = 0.55 mm in the anterior–posterior direction; the prostate remained within a 1-mm and 5-mm threshold for 93.9%±4.6% and 99.7%±0.4% of the time, respectively. Without real-time tracking, pass rates based on a γ index of 2%/2 mm in film dosimetry ranged between 66% and 72% for 3D-CRT, IMRT, and VMAT, on average. Real-time tracking increased pass rates to minimum 98% on average for 3D-CRT, IMRT, and VMAT. Conclusions: Real-time couch tracking resulted in submillimeter accuracy for prostate cancer, which transferred into high dosimetric accuracy independently of whether 3D-CRT, IMRT, or VMAT was used.

  9. Dosimetric Implications of Residual Tracking Errors During Robotic SBRT of Liver Metastases

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Mark [Department for Radiation Oncology, University Medical Center Schleswig-Holstein, Kiel (Germany); Tuen Mun Hospital, Hong Kong (China); Grehn, Melanie [Department for Radiation Oncology, University Medical Center Schleswig-Holstein, Lübeck (Germany); Institute for Robotics and Cognitive Systems, University of Lübeck, Lübeck (Germany); Cremers, Florian [Department for Radiation Oncology, University Medical Center Schleswig-Holstein, Lübeck (Germany); Siebert, Frank-Andre [Department for Radiation Oncology, University Medical Center Schleswig-Holstein, Kiel (Germany); Wurster, Stefan [Saphir Radiosurgery Center Northern Germany, Güstrow (Germany); Department for Radiation Oncology, University Medicine Greifswald, Greifswald (Germany); Huttenlocher, Stefan [Saphir Radiosurgery Center Northern Germany, Güstrow (Germany); Dunst, Jürgen [Department for Radiation Oncology, University Medical Center Schleswig-Holstein, Kiel (Germany); Department for Radiation Oncology, University Clinic Copenhagen, Copenhagen (Denmark); Hildebrandt, Guido [Department for Radiation Oncology, University Medicine Rostock, Rostock (Germany); Schweikard, Achim [Institute for Robotics and Cognitive Systems, University of Lübeck, Lübeck (Germany); Rades, Dirk [Department for Radiation Oncology, University Medical Center Schleswig-Holstein, Lübeck (Germany); Ernst, Floris [Institute for Robotics and Cognitive Systems, University of Lübeck, Lübeck (Germany); and others

    2017-03-15

    Purpose: Although the metric precision of robotic stereotactic body radiation therapy in the presence of breathing motion is widely known, we investigated the dosimetric implications of breathing phase–related residual tracking errors. Methods and Materials: In 24 patients (28 liver metastases) treated with the CyberKnife, we recorded the residual correlation, prediction, and rotational tracking errors from 90 fractions and binned them into 10 breathing phases. The average breathing phase errors were used to shift and rotate the clinical tumor volume (CTV) and planning target volume (PTV) for each phase to calculate a pseudo 4-dimensional error dose distribution for comparison with the original planned dose distribution. Results: The median systematic directional correlation, prediction, and absolute aggregate rotation errors were 0.3 mm (range, 0.1-1.3 mm), 0.01 mm (range, 0.00-0.05 mm), and 1.5° (range, 0.4°-2.7°), respectively. Dosimetrically, 44%, 81%, and 92% of all voxels differed by less than 1%, 3%, and 5% of the planned local dose, respectively. The median coverage reduction for the PTV was 1.1% (range in coverage difference, −7.8% to +0.8%), significantly depending on correlation (P=.026) and rotational (P=.005) error. With a 3-mm PTV margin, the median coverage change for the CTV was 0.0% (range, −1.0% to +5.4%), not significantly depending on any investigated parameter. In 42% of patients, the 3-mm margin did not fully compensate for the residual tracking errors, resulting in a CTV coverage reduction of 0.1% to 1.0%. Conclusions: For liver tumors treated with robotic stereotactic body radiation therapy, a safety margin of 3 mm is not always sufficient to cover all residual tracking errors. Dosimetrically, this translates into only small CTV coverage reductions.

  10. Dosimetric Implications of Residual Tracking Errors During Robotic SBRT of Liver Metastases

    International Nuclear Information System (INIS)

    Chan, Mark; Grehn, Melanie; Cremers, Florian; Siebert, Frank-Andre; Wurster, Stefan; Huttenlocher, Stefan; Dunst, Jürgen; Hildebrandt, Guido; Schweikard, Achim; Rades, Dirk; Ernst, Floris

    2017-01-01

    Purpose: Although the metric precision of robotic stereotactic body radiation therapy in the presence of breathing motion is widely known, we investigated the dosimetric implications of breathing phase–related residual tracking errors. Methods and Materials: In 24 patients (28 liver metastases) treated with the CyberKnife, we recorded the residual correlation, prediction, and rotational tracking errors from 90 fractions and binned them into 10 breathing phases. The average breathing phase errors were used to shift and rotate the clinical tumor volume (CTV) and planning target volume (PTV) for each phase to calculate a pseudo 4-dimensional error dose distribution for comparison with the original planned dose distribution. Results: The median systematic directional correlation, prediction, and absolute aggregate rotation errors were 0.3 mm (range, 0.1-1.3 mm), 0.01 mm (range, 0.00-0.05 mm), and 1.5° (range, 0.4°-2.7°), respectively. Dosimetrically, 44%, 81%, and 92% of all voxels differed by less than 1%, 3%, and 5% of the planned local dose, respectively. The median coverage reduction for the PTV was 1.1% (range in coverage difference, −7.8% to +0.8%), significantly depending on correlation (P=.026) and rotational (P=.005) error. With a 3-mm PTV margin, the median coverage change for the CTV was 0.0% (range, −1.0% to +5.4%), not significantly depending on any investigated parameter. In 42% of patients, the 3-mm margin did not fully compensate for the residual tracking errors, resulting in a CTV coverage reduction of 0.1% to 1.0%. Conclusions: For liver tumors treated with robotic stereotactic body radiation therapy, a safety margin of 3 mm is not always sufficient to cover all residual tracking errors. Dosimetrically, this translates into only small CTV coverage reductions.

  11. Radiation therapy for digestive tumors

    International Nuclear Information System (INIS)

    Piedbois, P.; Levy, E.; Thirion, P.; Martin, L.; Calitchi, E.; Otmezguine, Y.; Le Bourgeois, J.P.

    1995-01-01

    This brief review of radiation therapy of digestive tumors in 1994 seeks to provide practical answers to the most commonly asked questions: What is the place of radiation therapy versus chemotherapy for the treatment of these patients ? What are the approved indications of radiation therapy and which avenues of research are being explored ? Radiation therapy is used in over two-thirds of patients referred to an oncology department for a gastrointestinal tract tumor. The main indications are reviewed: cancer of the rectum and anal canal and, to a lesser extent, cancer of the esophagus and pancreas. The main focuses of current research include radiation therapy-chemotherapy combinations, intraoperative radiation therapy, and radiation therapy of hepatobiliary tumors. (authors). 23 refs., 1 fig

  12. MO-D-BRB-00: Pediatric Radiation Therapy Planning, Treatment, and Late Effects

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-06-15

    Most Medical Physicists working in radiotherapy departments see few pediatric patients. This is because, fortunately, children get cancer at a rate nearly 100 times lower than adults. Children have not smoked, abused alcohol, or been exposed to environmental carcinogens for decades, and of course, have not fallen victim to the aging process. Children get very different cancers than adults. Breast or prostate cancers, typical in adults, are rarely seen in children but instead a variety of tumors occur in children that are rarely seen in adults; examples are germinomas, ependymomas and primitive neuroectodermal tumors, which require treatment of the child’s brain or neuroblastoma, requiring treatment in the abdomen. The treatment of children with cancer using radiation therapy is one of the most challenging planning and delivery problems facing the physicist. This is because bones, brain, breast tissue, and other organs are more sensitive to radiation in children than in adults. Because most therapy departments treat mostly adults, when the rare 8 year-old patient comes to the department for treatment, the physicist may not understand the clinical issues of his disease which drive the planning and delivery decisions. Additionally, children are more prone than adults to developing secondary cancers after radiation. For bilateral retinoblastoma for example, an irradiated child has a 40% chance of developing a second cancer by age 50. The dosimetric tradeoffs made during the planning process are complex and require careful consideration for children treated with radiotherapy. In the first presentation, an overview of childhood cancers and their corresponding treatment techniques will be given. These can be some of the most complex treatments that are delivered in the radiation therapy department. These cancers include leukemia treated with total body irradiation, medulloblastoma, treated with craniospinal irradiation plus a conformal boost to the posterior fossa

  13. Electromagnetic Transponders Indicate Prostate Size Increase Followed by Decrease During the Course of External Beam Radiation Therapy

    International Nuclear Information System (INIS)

    King, Benjamin L.; Butler, Wayne M.; Merrick, Gregory S.; Kurko, Brian S.; Reed, Joshua L.; Murray, Brian C.; Wallner, Kent E.

    2011-01-01

    Purpose: Real-time image guidance enables more accurate radiation therapy by tracking target movement. This study used transponder positions to monitor changes in prostate volume that may be a source of dosimetric and target inaccuracy. Methods and Materials: Twenty-four men with biopsy-proven T1c-T3a prostate cancer each had three electromagnetic transponders implanted transperineally. Their coordinates were recorded by the Calypso system, and the perimeter of the triangle formed by the transponders was used to calculate prostate volumes at sequential time points throughout the course of radiation therapy to a dose of 81 Gy in 1.8-Gy fractions. Results: There was a significant decrease in mean prostate volume of 10.9% from the first to the final day of radiation therapy. The volume loss did not occur monotonically but increased in most patients (75%) during the first several weeks to a median maximum on Day 7. The volume increased by a mean of 6.1% before decreasing by a mean maximum difference of 18.4% to nadir (p < 0.001 for both increase and decrease). Glandular shrinkage was asymmetric, with the apex to right base dimension varying more than twice that of the lateral dimension. For all dimensions, the mean change was <0.5 cm. Conclusion: Real-time transponder positions indicated a volume increase during the initial days of radiation therapy and then significant and asymmetric shrinkage by the final day. Understanding and tracking volume fluctuations of the prostate during radiation therapy can help real-time imaging technology perform to its fullest potential.

  14. Dosimetric Comparison of Helical Tomotherapy and Dynamic Conformal Arc Therapy in Stereotactic Radiosurgery for Vestibular Schwannomas

    International Nuclear Information System (INIS)

    Lee, Tsair-Fwu; Chao, Pei-Ju; Wang, Chang-Yu; Lan, Jen-Hong; Huang, Yu-Je; Hsu, Hsuan-Chih; Sung, Chieh-Cheng; Su, Te-Jen; Lian, Shi-Long; Fang, Fu-Min

    2011-01-01

    The dosimetric results of stereotactic radiosurgery (SRS) for vestibular schwannoma (VS) performed using dynamic conformal arc therapy (DCAT) with the Novalis system and helical TomoTherapy (HT) were compared using plan quality indices. The HT plans were created for 10 consecutive patients with VS previously treated with SRS using the Novalis system. The dosimetric indices used to compare the techniques included the conformity index (CI) and homogeneity index (HI) for the planned target volume (PTV), the comprehensive quality index (CQI) for nine organs at risk (OARs), gradient score index (GSI) for the dose drop-off outside the PTV, and plan quality index (PQI), which was verified using the plan quality discerning power (PQDP) to incorporate 3 plan indices, to evaluate the rival plans. The PTV ranged from 0.27-19.99 cm 3 (median 3.39 cm 3 ), with minimum required PTV prescribed doses of 10-16 Gy (median 12 Gy). Both systems satisfied the minimum required PTV prescription doses. HT conformed better to the PTV (CI: 1.51 ± 0.23 vs. 1.94 ± 0.34; p < 0.01), but had a worse drop-off outside the PTV (GSI: 40.3 ± 10.9 vs. 64.9 ± 13.6; p < 0.01) compared with DCAT. No significant difference in PTV homogeneity was observed (HI: 1.08 ± 0.03 vs. 1.09 ± 0.02; p = 0.20). HT had a significantly lower maximum dose in 4 OARs and significant lower mean dose in 1 OAR; by contrast, DCAT had a significantly lower maximum dose in 1 OAR and significant lower mean dose in 2 OARs, with the CQI of the 9 OARs = 0.92 ± 0.45. Plan analysis using PQI (HT 0.37 ± 0.12 vs. DCAT 0.65 ± 0.08; p < 0.01), and verified using the PQDP, confirmed the dosimetric advantage of HT. However, the HT system had a longer beam-on time (33.2 ± 7.4 vs. 4.6 ± 0.9 min; p < 0.01) and consumed more monitor units (16772 ± 3803 vs. 1776 ± 356.3; p < 0.01). HT had a better dose conformity and similar dose homogeneity but worse dose gradient than DCAT. Plan analysis confirmed the dosimetric advantage of HT

  15. Use of personal radiation protection tools and individual dosimetric monitoring in a sample of interventional cardiologists in France, 2005-2009

    International Nuclear Information System (INIS)

    Jacob, S.; Bertrand, A.; Laurier, D.; Bernier, M.O.; Scanff, P.

    2014-01-01

    Interventional cardiologists (ICs) are repeatedly exposed to scattered ionising radiation during the cardiac procedures they perform, and radiation protection is an important issue for these medical professionals. The use of radiation protection tools is particularly relevant to this population. SISERI (Systeme d'Information de la Surveillance de l'Exposition aux Rayonnement Ionisants, that is, an information system for monitoring exposure to ionising radiation) is a register that stores personal dosimeter readings for dosimetric monitoring. This paper, based on data for a sample of French ICs from the O'CLOC epidemiological study, aims to provide an overview of the use of radiation protection equipment and dosimetric devices reported by ICs in a specific questionnaire as well as the dosimetric information found in the SISERI database for this population. Material and Methods - Annual information on interventional cardiology activity for the period from 01/01/2005 to 31/12/2009 was collected in an occupational questionnaire. ICs were asked to report the frequency in which they used individual dosimeter and radiation protection tools (lead apron, thyroid shield, eye-wear or face shield, ceiling-suspended shield) as follows: never (0% of the time), occasionally ( 50%), always (100%). We retrieved their medical radiation exposure information (monitored status and monthly effective doses) from the SISERI database for the period 2005-2009. Results - Information for 132 ICs (mean age in 2005 = 46 ± 7 years) was available. All ICs reported routine use of lead aprons, in contrast to their occasional use of lead eye-wear or face shields. During the study period, 49% reported systematic use of personal dosimeters, and 21% more regular use. On the other hand, 18% never used a dosimeter during this period. The SISTERI database included 92% of our population, 73% of whom had complete annual dose monitoring in SISERI (corresponding to at least 11 months per year of recorded

  16. Dosimetric reproduction of a left-breast 3DCRT field-in-field radiation therapy planning in an anthropomorphic and anthropometric phantom

    Energy Technology Data Exchange (ETDEWEB)

    Nogueira, Luciana B., E-mail: lucibn19@yahoo.com.br, E-mail: jonymarques@uol.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Anatomia e Imagem; Barsanelli, Cristiane; Geraldo, Jony M., E-mail: cbarsanelli@yahoo.com.br [Hospital Luxemburgo, Instituto Mário Penna, Belo Horizonte, MG (Brazil); Aquino, Jean Carlos; Campos, Tarcísio P. Ribeiro, E-mail: jeancarlosaquino@outlook.com, E-mail: tprcampos@yahoo.com.br [Universidade Federal de Minas Gerais (UGMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear

    2017-07-01

    The proposal of this study was to reproduce the dosimetry established in a treatment planning system (TPS) following a 3D conformational radiation therapy (3DCRT) protocol of two parallel-opposite fields applied to the left-breast in a thorax phantom, with the use of the field-in-field technique. Computed tomography (CT) images of the anthropomorphic and anthropometric phantom of the thorax with mobile breasts were generated. This phantom was developed by the NRI / UFMG research group. The generated images were transferred to the planning system XiO version-5 for the elaboration of the breast tele therapeutic planning with 2 Gy per fraction, in 25 fractions, with prescribed dose of 50 Gy. A set of ten EBT2 radiochromic films were irradiated at different doses. The values of RGB (Red, Green, Blue) of the radiochromic films were obtained by scanning and data transformed in optical density (OD), whose values were used to construct the calibration curve. EBT2 radiochromic films were positioned outside and inside of the thorax phantom: internally in the right and left lungs, on the face of the heart, in the glandular breast tissue-equivalent (TE) and in the left breast skin. After phantom radiation at the linear accelerator 6 MV Elekta Precise reproducing the 3DCRT, the radiochromic films were digitized after 24 h of exposure. The measurements of the intensities of the films in RGB were measured in the software ImageJ, transformed in optical density and converted in bidimensional dose distributions, applying the calibration curve. The experimental dosimetric data were analyzed and compared with values generated in the TPS. In addition, graphics and dose-volume histograms (DVH) were developed. The dose measurements in the glandular-TE in breast did not present statistically significant differences in relation to values at equivalent positions generated in the TPS. The organs at risk received doses below the reference values, according to TPS. It was verified the

  17. Dosimetric reproduction of a left-breast 3DCRT field-in-field radiation therapy planning in an anthropomorphic and anthropometric phantom

    International Nuclear Information System (INIS)

    Nogueira, Luciana B.; Aquino, Jean Carlos; Campos, Tarcísio P. Ribeiro

    2017-01-01

    The proposal of this study was to reproduce the dosimetry established in a treatment planning system (TPS) following a 3D conformational radiation therapy (3DCRT) protocol of two parallel-opposite fields applied to the left-breast in a thorax phantom, with the use of the field-in-field technique. Computed tomography (CT) images of the anthropomorphic and anthropometric phantom of the thorax with mobile breasts were generated. This phantom was developed by the NRI / UFMG research group. The generated images were transferred to the planning system XiO version-5 for the elaboration of the breast tele therapeutic planning with 2 Gy per fraction, in 25 fractions, with prescribed dose of 50 Gy. A set of ten EBT2 radiochromic films were irradiated at different doses. The values of RGB (Red, Green, Blue) of the radiochromic films were obtained by scanning and data transformed in optical density (OD), whose values were used to construct the calibration curve. EBT2 radiochromic films were positioned outside and inside of the thorax phantom: internally in the right and left lungs, on the face of the heart, in the glandular breast tissue-equivalent (TE) and in the left breast skin. After phantom radiation at the linear accelerator 6 MV Elekta Precise reproducing the 3DCRT, the radiochromic films were digitized after 24 h of exposure. The measurements of the intensities of the films in RGB were measured in the software ImageJ, transformed in optical density and converted in bidimensional dose distributions, applying the calibration curve. The experimental dosimetric data were analyzed and compared with values generated in the TPS. In addition, graphics and dose-volume histograms (DVH) were developed. The dose measurements in the glandular-TE in breast did not present statistically significant differences in relation to values at equivalent positions generated in the TPS. The organs at risk received doses below the reference values, according to TPS. It was verified the

  18. Dose discrepancy between planning system estimation and measurement in spine stereotactic body radiation therapy: A case report

    International Nuclear Information System (INIS)

    Arumugam, Sankar; Xing, Aitang; Vial Philip; Berry Megan; Ochoa, Cesar; Beeksma, Bradley

    2017-01-01

    Stereotactic body radiation therapy (SBRT) to treat spinal metastases has shown excellent clinical outcomes for local control. High dose gradients wrapping around spinal cord make this treatment technically challenging. In this work, we present a spine SBRT case where a dosimetric error was identified during pre-treatment dosimetric quality assurance (QA). A patient with metastasis in T7 vertebral body consented to undergo SBRT. A dual arc volumetric modulated arc therapy plan was generated on the Pinnacle treatment planning system (TPS) with a 6 MV Elekta machine using gantry control point spacing of 4°. Standard pre-treatment QA measurements were performed, including ArcCHECK, ion chamber in CTV and spinal cord (SC) region and film measurements in multiple planes. While the dose measured at CTV region showed good agreement with TPS, the dose measured to the SC was significantly higher than reported by TPS in the original and repeat plans. Acceptable agreement was only achieved when the gantry control point spacing was reduced to 3°. A potentially harmful dose error was identified by pre-treatment QA. TPS parameter settings used safely in conventional treatments should be re-assessed for complex treatments.

  19. Dosimetric evaluation of lithium carbonate (Li2CO3) as a dosemeter for gamma-radiation dose measurements.

    Science.gov (United States)

    Popoca, R; Ureña-Núñez, F

    2009-06-01

    This work reports the possibility of using lithium carbonate as a dosimetric material for gamma-radiation measurements. Carboxi-radical ions, CO(2)(-) and CO(3)(-), arise from the gamma irradiation of Li(2)CO(3), and these radical ions can be quantified by electron paramagnetic resonance (EPR) spectrometry. The EPR-signal response of gamma-irradiated lithium carbonate has been investigated to determine some dosimetric characteristics such as: peak-to-peak signal intensity versus gamma dose received, zero-dose response, signal fading, signal repeatability, batch homogeneity, dose rate effect and stability at different environmental conditions. Using the conventional peak-to-peak method of stable ion radicals, it is concluded that lithium carbonate could be used as a gamma dosemeter in the range of 3-100 Gy.

  20. Feasibility of magnetic resonance imaging-guided liver stereotactic body radiation therapy: A comparison between modulated tri-cobalt-60 teletherapy and linear accelerator-based intensity modulated radiation therapy.

    Science.gov (United States)

    Kishan, Amar U; Cao, Minsong; Wang, Pin-Chieh; Mikaeilian, Argin G; Tenn, Stephen; Rwigema, Jean-Claude M; Sheng, Ke; Low, Daniel A; Kupelian, Patrick A; Steinberg, Michael L; Lee, Percy

    2015-01-01

    The purpose of this study was to investigate the dosimetric feasibility of liver stereotactic body radiation therapy (SBRT) using a teletherapy system equipped with 3 rotating (60)Co sources (tri-(60)Co system) and a built-in magnetic resonance imager (MRI). We hypothesized tumor size and location would be predictive of favorable dosimetry with tri-(60)Co SBRT. The primary study population consisted of 11 patients treated with SBRT for malignant hepatic lesions whose linear accelerator (LINAC)-based SBRT plans met all mandatory Radiation Therapy Oncology Group (RTOG) 1112 organ-at-risk (OAR) constraints. The secondary study population included 5 additional patients whose plans did not meet the mandatory constraints. Patients received 36 to 60 Gy in 3 to 5 fractions. Tri-(60)Co system SBRT plans were planned with ViewRay system software. All patients in the primary study population had tri-(60)Co SBRT plans that passed all RTOG constraints, with similar planning target volume coverage and OAR doses to LINAC plans. Mean liver doses and V10Gy to the liver, although easily meeting RTOG 1112 guidelines, were significantly higher with tri-(60)Co plans. When the 5 additional patients were included in a univariate analysis, the tri-(60)Co SBRT plans were still equally able to pass RTOG constraints, although they did have inferior ability to pass more stringent liver and kidney constraints (P < .05). A multivariate analysis found the ability of a tri-(60)Co SBRT plan to meet these constraints depended on lesion location and size. Patients with smaller or more peripheral lesions (as defined by distance from the aorta, chest wall, liver dome, and relative lesion volume) were significantly more likely to have tri-(60)Co plans that spared the liver and kidney as well as LINAC plans did (P < .05). It is dosimetrically feasible to perform liver SBRT with a tri-(60)Co system with a built-in MRI. Patients with smaller or more peripheral lesions are more likely to have optimal liver

  1. Dosimetric Impact of Primary Planning Parameters in Dynamic Conformal Arc Technique for Lung SBRT

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ji Yeon; Suh, Tae Suk [Dept. of Biomedical Engineering, The Catholic University of Korea, Seoul (Korea, Republic of); Kim, Si Yong [Dept. of Radiation Oncology, Mayo Clinic, Jacksonvile (United States); Lee, Jeong Woo [Dept. of Radiation Oncology, Konkuk University Medical Center, Seoul (Korea, Republic of); Choi, Kyoung Sik [Dept. of Radiation Oncology, Anyang SAM Hospital, Anyang (Korea, Republic of)

    2011-04-15

    As one of the stereotactic body radiation therapy (SBRT) techniques, dynamic conformal arc therapy (DCAT) is commonly adopted to efficiently deliver conformal doses. However, as the DCAT uses numerous beams at individual control points, the dosimetric errors generated from each beam can be accumulated and manifested. In SBRT, therefore, due to the high fractional dose within a few fractions to moving target, the determination of the applied plan parameters can be critical and the evaluation of dosimetric impact of planning parameters would play an important role in DCAT planning process. In this study, we systematically evaluated the dosimetric influence caused by the variable grid size and the angular increment in DCAT for lung SBRT. Dose variations with different parameters were estimated for spherical and elongated tumors on an anthropomorphic phantom. The systematic analysis of the generated dose variation would guide to determine appropriate plan parameters and to estimate the dose errors in planning process in a clinical perspective of DCAT. It was found that two plan parameters, grid size and angular increment, in DCAT could cause non-negligible dose uncertainty. Coarse grid size led patients to get unnecessary overdose. Coarse angular increment could make significantly inaccurate prediction of OAR dose, resulting in either over- or under- estimation depending on the location of OAR relative to the isocenter.

  2. Geometric factors influencing dosimetric sparing of the parotid glands using IMRT

    International Nuclear Information System (INIS)

    Hunt, Margie A.; Jackson, Andrew; Narayana, Ashwatha; Lee, Nancy

    2006-01-01

    Purpose/Objective: To determine the relationship between the parotid volume, parotid-planning target volume (PTV) overlap, and dosimetric sparing of the parotid with intensity-modulated radiation therapy (IMRT). Methods and Materials: Parotid data were collected retrospectively for 51 patients treated with simultaneous boost IMRT. Unresectable patients received 54 or 59.4 Gy to subclinical disease, 70 Gy to gross disease. Patients treated postoperatively received 54, 60, and 66 Gy to low-risk, high-risk, and tumor bed regions. Volume and mean dose of each gland and gland segments outside of and overlapping the PTV were collected. Proximity of each gland to each PTV was recorded. Results: Dosimetric sparing (mean dose ≤26.5 Gy) was achieved in 66 of 71 glands with ≤21% parotid-PTV overlap and 8 of 23 glands with >21% overlap (p = 21%. Median mean dose was 25.9 Gy to glands overlapping PTV 54 or PTV 59 alone and 30.0 Gy to those abutting PTV 7 (p 7 was associated with higher parotid dose, satisfactory sparing was achieved in 24 of 43 ipsilateral glands. Conclusions: Dosimetric sparing of the parotid is feasible when the parotid-PTV overlap is less than approximately 20%. With more overlap, sparing may result in low doses within the overlap region, possibly leading to inadequate PTV coverage. Gland proximity to the high-dose PTV is associated with higher mean dose but does not always preclude dosimetric sparing

  3. Clinical implementation and quality assurance for intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Ma, C.-M.; Price, R.; McNeeley, S.; Chen, L.; Li, J.S.; Wang, L.; Ding, M.; Fourkal, E.; Qin, L.

    2002-01-01

    This paper describes the clinical implementation and quality assurance (QA) for intensity-modulated radiation therapy (IMRT) based on the experience at Fox Chase Cancer Center, Philadelphia, USA. We will review our procedures for the clinical implementation of the IMRT technique and the requirements for patient immobilization, target delineation, treatment optimization, beam delivery and system administration. We will discuss the dosimetric requirements and measurement procedures for beam commissioning and dosimetry verification for IMRT. We will examine the details of model-based dose calculation for IMRT treatment planning and the potential problems with such dose calculation algorithms. We will discuss the effect of beam delivery systems on the actual dose distributions received by the patients and the methods to incorporate such effects in the treatment optimization process. We will investigate the use of the Monte Carlo method for dose calculation and treatment verification for IMRT

  4. Gel Dosimetry Analysis of Gold Nanoparticle Application in Kilovoltage Radiation Therapy

    International Nuclear Information System (INIS)

    Marques, T; Schwarcke, M; Garrido, C; Zucolot, V; Baffa, O; Nicolucci, P

    2010-01-01

    In this work gold nanoparticles (AuNP) were embedded in MAGIC-f gel and irradiated in a 250 kV x-ray clinical beam. The signal of non-irradiated gel samples containing AuNPs showed maximum difference of 0.5% related to gel without nanoparticles. Different AuNPs concentrations were studied: 0.10 mM, 0.05 mM and 0.02 mM, presenting dose enhancements of 106%, 90% and 77% respectively. Monte Carlo spectrometry was performed to quantify theoretical changes in photon energy spectrums due to AuNPs presence. Concordance between simulated dose enhancements and gel dosimetry measurements was better than 97% to all concentrations studied. This study evidences that polymer gel dosimetry as a suitable tool to perform dosimetric investigations of nanoparticle applications in Radiation Therapy.

  5. The physics of radiation therapy

    CERN Document Server

    Khan, Faiz M

    2009-01-01

    Dr. Khan's classic textbook on radiation oncology physics is now in its thoroughly revised and updated Fourth Edition. It provides the entire radiation therapy team—radiation oncologists, medical physicists, dosimetrists, and radiation therapists—with a thorough understanding of the physics and practical clinical applications of advanced radiation therapy technologies, including 3D-CRT, stereotactic radiotherapy, HDR, IMRT, IGRT, and proton beam therapy. These technologies are discussed along with the physical concepts underlying treatment planning, treatment delivery, and dosimetry. This Fourth Edition includes brand-new chapters on image-guided radiation therapy (IGRT) and proton beam therapy. Other chapters have been revised to incorporate the most recent developments in the field. This edition also features more than 100 full-color illustrations throughout.

  6. Radiation therapy for prostate cancer

    International Nuclear Information System (INIS)

    Nakamura, Katsumasa

    2001-01-01

    In Japan, where the mortality rate of prostate cancer is lower than in Western countries, radical prostatectomy or hormonal therapy has been applied more frequently than radiation therapy. However, the number of patients with prostate cancer has been increasing recently and the importance of radiation therapy has rapidly been recognized. Although there have been no randomized trials, results from several institutions in Western countries suggest that similar results of cancer control are achieved with either radiation therapy or radical prostatectomy. For higher-risk cases, conformal high-dose therapy or adjuvant hormonal therapy is more appropriate. In this article, the results of radiation therapy for prostate cancer were reviewed, with a view to the appropriate choice of therapy in Japan. (author)

  7. Radiation-hygienic estimation of interstitial gamma therapy conducted according to principle of subsequent introduction of radioactive sources

    International Nuclear Information System (INIS)

    Zamyatin, O.A.; Golikov, V.Ya.; Korenkov, I.P.; Ter-Kazar'yan, N.S.; Mindlin, G.M.

    1978-01-01

    A comparative study of two radiation-hygienic methods of interstitial gamma-therapy: with subsequent introduction of radioactive needles of a standard type; with subsequent manual introduction of 60 Co sources have been carried out. Chronometry-dosimetric methods of investigation and the methods of individual dosimetry underlie the studies. The obtained data showed, that doses of irradiation to which medical personnel is subjected during the use of the method of subsequent manual introduction of the active sources are 3-4 times lower, than those during the introduction of standard radioactive needles with a higher quality of the procedure performance, ensuring a good therapeutic effect. All this makes it possible to consider interstitial gamma-therapy with the use of the principle of subsequent introduction of the source to be a more perspective method than interstitial gamma-therapy with the use standard radioactive needless 60 Co

  8. Gamma dosimetric parameters in some skeletal muscle relaxants

    Science.gov (United States)

    Manjunatha, H. C.

    2017-09-01

    We have studied the attenuation of gamma radiation of energy ranging from 84 keV to 1330 keV (^{170}Tm, ^{22}Na,^{137}Cs, and ^{60}Co) in some commonly used skeletal muscle relaxants such as tubocurarine chloride, gallamine triethiodide, pancuronium bromide, suxamethonium bromide and mephenesin. The mass attenuation coefficient is measured from the attenuation experiment. In the present work, we have also proposed the direct relation between mass attenuation coefficient (μ /ρ ) and mass energy absorption coefficient (μ _{en}/ρ ) based on the nonlinear fitting procedure. The gamma dosimetric parameters such as mass energy absorption coefficient (μ _{en}/ρ ), effective atomic number (Z_{eff}), effective electron density (N_{el}), specific γ-ray constant, air kerma strength and dose rate are evaluated from the measured mass attentuation coefficient. These measured gamma dosimetric parameters are compared with the theoretical values. The measured values agree with the theoretical values. The studied gamma dosimetric values for the relaxants are useful in medical physics and radiation medicine.

  9. Dosimetric characterization of a 2-D array of 223 solid state detectors for daily morning checks in Tomo Therapy equipment; Caracterizacion dosimetrica de un arreglo 2D de 223 detectores de estado solido para verificaciones matutinas diarias en un equipo de Tomo Terapia

    Energy Technology Data Exchange (ETDEWEB)

    Reyes S, U.; Sosa A, M. [Universidad de Guanajuato, Division de Ciencias e Ingenieria, Lomas del Bosque No. 103, Col. Lomas del Campestre, 37150 Leon, Guanajuato (Mexico); Vega C, H. R., E-mail: uvaldoreyes@hotmail.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas, Zac. (Mexico)

    2015-10-15

    Tomo Therapy is a new technique for the cancer treatment; however, the equipment must meet nearly all mechanical and dosimetric characteristics of a conventional linear accelerator for medical use. Daily quality controls are vital to the good operation of the equipment and thus guarantee excellent quality in the daily delivery of treatments. This paper presents the procedure of the dosimetric characterization of a two-dimensional array of 223 solid state detectors, called TomoDose of the Sun Nuclear Company. Dosimetric important criteria are established to perform these checks quickly and accurately. Dosimetric tests proposed are: repeatability, linearity, dependence of Sad and SSD. Some results are compared with readings of the ionization chamber Exradim A1SL. Finally the results of 30 consecutive days are presented to establish criteria for evidence of dose, field size, symmetry and flattening of the radiation beam on Tomo Therapy equipment. Expected values for daily verification are: Dose constancy of 194.89 c Gy, σ= 1.31 c Gy, symmetry in the X axis of -0.19 %, σ=0.08 %, symmetry in the Y axis of 1.66 %, σ= 0.05 %, flattened in the X axis of 25.71 %, σ= 0.05 % and flattened in the Y axis of 6.41 %, σ= 10.23 %. Field sizes obtained were 40.45 cm in the X axis and 5.10 on the Y axis, with standard deviations of 0.02 cm and 0.01 cm, respectively. TomoDose dosimetric values, compared to the values obtained with ionization chamber, presented differences smaller than 2%. (Author)

  10. Potential application of metal nanoparticles for dosimetric systems: Concepts and perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Guidelli, Eder José, E-mail: ederguidelli@pg.ffclrp.usp.br; Baffa, Oswaldo, E-mail: ederguidelli@pg.ffclrp.usp.br [Departamento de Física, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Av. Bandeirantes, 3900, 14040-901, Ribeirão Preto, SP (Brazil)

    2014-11-07

    Metallic nanoparticles increase the delivered dose and consequently enhance tissue radio sensitization during radiation therapy of cancer. The Dose Enhancement Factor (DEF) corresponds to the ratio between the dose deposited on a tissue containing nanoparticles, and the dose deposited on a tissue without nanoparticles. In this sense, we have used electron spin resonance spectroscopy (ESR) to investigate how silver and gold nanoparticles affect the dose deposition in alanine dosimeters, which act as a surrogate of soft tissue. Besides optimizing radiation absorption by the dosimeter, the optical properties of these metal nanoparticles could also improve light emission from materials employed as radiation detectors. Therefore, we have also examined how the plasmonic properties of noble metal nanoparticles could enhance radiation detection using optically stimulated luminescence (OSL) dosimetry. This work will show results on how the use of gold and silver nanoparticles are beneficial for the ESR and OSL dosimetric techniques, and will describe the difficulties we have been facing, the challenges to overcome, and the perspectives.

  11. Predicted Rates of Secondary Malignancies From Proton Versus Photon Radiation Therapy for Stage I Seminoma

    Energy Technology Data Exchange (ETDEWEB)

    Simone, Charles B., E-mail: csimone@alumni.upenn.edu [Department of Radiation Oncology, Hospital of University of Pennsylvania, Philadelphia, Pennsylvania (United States); Radiation Oncology Branch, National Cancer Institute, National Institutes of Health, Bethesda, Maryland (United States); Kramer, Kevin [Henry M. Jackson Foundation for the Advancement of Military Medicine, Rockville, Maryland (United States); O' Meara, William P. [Division of Radiation Oncology, National Naval Medical Center, Bethesda, Maryland (United States); Bekelman, Justin E. [Department of Radiation Oncology, Hospital of University of Pennsylvania, Philadelphia, Pennsylvania (United States); Belard, Arnaud [Henry M. Jackson Foundation for the Advancement of Military Medicine, Rockville, Maryland (United States); McDonough, James [Department of Radiation Oncology, Hospital of University of Pennsylvania, Philadelphia, Pennsylvania (United States); O' Connell, John [Radiation Oncology Service, Walter Reed Army Medical Center, Washington, DC (United States)

    2012-01-01

    Purpose: Photon radiotherapy has been the standard adjuvant treatment for stage I seminoma. Single-dose carboplatin therapy and observation have emerged as alternative options due to concerns for acute toxicities and secondary malignancies from radiation. In this institutional review board-approved study, we compared photon and proton radiotherapy for stage I seminoma and the predicted rates of excess secondary malignancies for both treatment modalities. Methods and Material: Computed tomography images from 10 consecutive patients with stage I seminoma were used to quantify dosimetric differences between photon and proton therapies. Structures reported to be at increased risk for secondary malignancies and in-field critical structures were contoured. Reported models of organ-specific radiation-induced cancer incidence rates based on organ equivalent dose were used to determine the excess absolute risk of secondary malignancies. Calculated values were compared with tumor registry reports of excess secondary malignancies among testicular cancer survivors. Results: Photon and proton plans provided comparable target volume coverage. Proton plans delivered significantly lower mean doses to all examined normal tissues, except for the kidneys. The greatest absolute reduction in mean dose was observed for the stomach (119 cGy for proton plans vs. 768 cGy for photon plans; p < 0.0001). Significantly more excess secondary cancers per 10,000 patients/year were predicted for photon radiation than for proton radiation to the stomach (4.11; 95% confidence interval [CI], 3.22-5.01), large bowel (0.81; 95% CI, 0.39-1.01), and bladder (0.03; 95% CI, 0.01-0.58), while no difference was demonstrated for radiation to the pancreas (0.02; 95% CI, -0.01-0.06). Conclusions: For patients with stage I seminoma, proton radiation therapy reduced the predicted secondary cancer risk compared with photon therapy. We predict a reduction of one additional secondary cancer for every 50 patients

  12. Realisation of dosimetric studies for working stations with a risk of exposure to ionizing radiations. Practical guide

    International Nuclear Information System (INIS)

    Donadille, L.; Queinnec, F.; Bottollier-Depois, J.F.; Clairand, I.; Rehel, J.L.; Deligne, J.M.; Aubert, B.; Jourdain, J.R.; Rannou, A.

    2007-01-01

    This guide proposes a methodological approach to help carry out dosimetric workplace studies complying with the French regulation, and necessary to identify risks of radiological exposure, optimize radiation protection, classify the workers into different categories and the workplaces into different areas. Additional information is provided relating the main objectives of a workplace study, the French regulatory context, main sources and pathways of exposure to ionizing radiation. Radiation protection and operational quantities are reminded. Recommendations about the selection and use of detectors and about the implementation of calculation methods are also provided. The general methodological approach is applied and developed into 'workplace sheets', each one devoted to a particular type of workplace. (author)

  13. Improved Dosimetric and Clinical Outcomes With Intensity-Modulated Radiotherapy for Head-and-Neck Cancer of Unknown Primary Origin

    International Nuclear Information System (INIS)

    Chen, Allen M.; Li Baoqing; Farwell, D. Gregory; Marsano, Joseph; Vijayakumar, Srinivasan; Purdy, James A.

    2011-01-01

    Purpose: To compare differences in dosimetric, clinical, and quality-of-life endpoints among a cohort of patients treated by intensity-modulated radiotherapy (IMRT) and conventional radiotherapy (CRT) for head-and-neck cancer of unknown primary origin. Methods and Materials: The medical records of 51 patients treated by radiation therapy for squamous cell carcinoma of the head and neck presenting as cervical lymph node metastasis of occult primary origin were reviewed. Twenty-four patients (47%) were treated using CRT, and 27 (53%) were treated using IMRT. The proportions of patients receiving concurrent chemotherapy were 54% and 63%, respectively. Results: The 2-year estimates of overall survival, local-regional control, and disease-specific survival for the entire patient population were 86%, 89%, and84%, respectively. There were no significant differences in any of these endpoints with respect to radiation therapy technique (p > 0.05 for all). Dosimetric analysis revealed that the use of IMRT resulted in significant improvements with respect to mean dose and V30 to the contralateral (spared) parotid gland. In addition, mean doses to the ipsilateral inner and middle ear structures were significantly reduced with IMRT (p < 0.05 for all). The incidence of severe xerostomia in the late setting was 58% and 11% among patients treated by CRT and IMRT, respectively (p < 0.001). The percentages of patients who were G-tube dependent at 6 months after treatment were 42% and 11%, respectively (p < 0.001). Conclusions: IMRT results in significant improvements in the therapeutic ratio among patients treated by radiation therapy for head-and-neck cancer of unknown primary origin.

  14. Dosimetric methodology of the ICRP

    International Nuclear Information System (INIS)

    Eckerman, K.F.

    1994-01-01

    Establishment of guidance for the protection of workers and members of the public from radiation exposures necessitates estimation of the radiation dose to tissues of the body at risk. The dosimetric methodology formulated by the International Commission on Radiological Protection (ICRP) is intended to be responsive to this need. While developed for radiation protection, elements of the methodology are often applied in addressing other radiation issues; e.g., risk assessment. This chapter provides an overview of the methodology, discusses its recent extension to age-dependent considerations, and illustrates specific aspects of the methodology through a number of numerical examples

  15. Radiation therapy

    International Nuclear Information System (INIS)

    Bader, J.L.; Glatstein, E.

    1987-01-01

    The radiation oncologist encounters the critically ill immunosuppressed patient in four settings. First, the newly diagnosed cancer patient presents for initial evaluation and treatment, with immunosuppression from the cancer itself, malnutrition, concomitant infectious disease, prior drug or alcohol abuse or other medical problems. Second, the previously treated cancer patient presents with metastatic or recurrent primary cancer causing local symptoms. Immune dysfunction in this setting may be due to prior chemotherapy and/or radiation as well as any of the original factors. Third, the patient previously treated with radiation presents with a life-threatening problem possibly due to complications of prior therapy. In this setting, the radiation oncologist is asked to evaluate the clinical problem and to suggest whether radiation might be causing part or all of the problem and what can be done to treat these sequelae of radiation. Fourth, the patient with a benign diagnosis (not cancer) is seen with a problem potentially emeliorated by radiation (e.g., kidney transplant rejection, preparation for transplant, or intractable rheumatoid arthritis). This chapter reviews these four issues and presents clinical and radiobiologic principles on which recommendations for therapy are based

  16. SU-C-213-03: Custom 3D Printed Boluses for Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, B; Yang, M; Yan, Y; Rahimi, A; Chopra, R; Jiang, S [UT Southwestern Medical Center, Dallas, TX (United States)

    2015-06-15

    Purpose: To develop a clinical workflow and to commission the process of creating custom 3d printed boluses for radiation therapy. Methods: We designed a workflow to create custom boluses using a commercial 3D printer. Contours of several patients were deformably mapped to phantoms where the test bolus contours were designed. Treatment plans were created on the phantoms following our institutional planning guideline. The DICOM file of the bolus contours were then converted to stereoLithography (stl) file for the 3d printer. The boluses were printed on a commercial 3D printer using polylactic acid (PLA) material. Custom printing parameters were optimized in order to meet the requirement of bolus composition. The workflow was tested on multiple anatomical sites such as skull, nose and chest wall. The size of boluses varies from 6×9cm2 to 12×25cm2. To commission the process, basic CT and dose properties of the printing materials were measured in photon and electron beams and compared against water and soft superflab bolus. Phantoms were then scanned to confirm the placement of custom boluses. Finally dose distributions with rescanned CTs were compared with those computer-generated boluses. Results: The relative electron density(1.08±0.006) of the printed boluses resemble those of liquid tap water(1.04±0.004). The dosimetric properties resemble those of liquid tap water(1.04±0.004). The dosimetric properties were measured at dmax with an ion chamber in electron and photon open beams. Compared with solid water and soft bolus, the output difference was within 1% for the 3D printer material. The printed boluses fit well to the phantom surfaces on CT scans. The dose distribution and DVH based on the printed boluses match well with those based on TPS generated boluses. Conclusion: 3d printing provides a cost effective and convenient solution for patient-specific boluses in radiation therapy.

  17. SU-C-213-03: Custom 3D Printed Boluses for Radiation Therapy

    International Nuclear Information System (INIS)

    Zhao, B; Yang, M; Yan, Y; Rahimi, A; Chopra, R; Jiang, S

    2015-01-01

    Purpose: To develop a clinical workflow and to commission the process of creating custom 3d printed boluses for radiation therapy. Methods: We designed a workflow to create custom boluses using a commercial 3D printer. Contours of several patients were deformably mapped to phantoms where the test bolus contours were designed. Treatment plans were created on the phantoms following our institutional planning guideline. The DICOM file of the bolus contours were then converted to stereoLithography (stl) file for the 3d printer. The boluses were printed on a commercial 3D printer using polylactic acid (PLA) material. Custom printing parameters were optimized in order to meet the requirement of bolus composition. The workflow was tested on multiple anatomical sites such as skull, nose and chest wall. The size of boluses varies from 6×9cm2 to 12×25cm2. To commission the process, basic CT and dose properties of the printing materials were measured in photon and electron beams and compared against water and soft superflab bolus. Phantoms were then scanned to confirm the placement of custom boluses. Finally dose distributions with rescanned CTs were compared with those computer-generated boluses. Results: The relative electron density(1.08±0.006) of the printed boluses resemble those of liquid tap water(1.04±0.004). The dosimetric properties resemble those of liquid tap water(1.04±0.004). The dosimetric properties were measured at dmax with an ion chamber in electron and photon open beams. Compared with solid water and soft bolus, the output difference was within 1% for the 3D printer material. The printed boluses fit well to the phantom surfaces on CT scans. The dose distribution and DVH based on the printed boluses match well with those based on TPS generated boluses. Conclusion: 3d printing provides a cost effective and convenient solution for patient-specific boluses in radiation therapy

  18. Dosimetric essay in dental radiology; Experiencia dosimetrica en radiologia odontologica

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Salaberry, M [Ministerio de Industria, Energia y Mineria, Montevideo (Uruguay). Direccion Nacional de Tecnologia Nuclear; Dato Carfagna, A; Rodriguez Dorgia, R [Universidad de la Republica, Facultad de Odontologia , Montevideo (Uruguay)

    1999-12-31

    A neck study was observated in the tiroids glands,laryngeal zone, sensitive organs for the ionizing radiation for increase dental xray exams. Was selected 29th patients with radiography prescription complete (in the Odontology Faculty Clinics Uruguaian). It took radiographies with and without tiroids necklace and apron lead using dosemeters. Dosimetric studies had demonstrated good dose between patients. For measuring the radiation dose have been used TLD thermoluminescence dosimetric and Harshaw 6600 for read it. The thyroids necklace use and odontology postgrading for training course for dentistry was the two recommendations advised

  19. XRCC3 polymorphisms are associated with the risk of developing radiation-induced late xerostomia in nasopharyngeal carcinoma patients treated with intensity modulation radiated therapy.

    Science.gov (United States)

    Zou, Yan; Song, Tao; Yu, Wei; Zhao, Ruping; Wang, Yong; Xie, Ruifei; Chen, Tian; Wu, Bo; Wu, Shixiu

    2014-03-01

    The incidence of radiation-induced late xerostomia varies greatly in nasopharyngeal carcinoma patients treated with radiotherapy. The single-nucleotide polymorphisms in genes involved in DNA repair and fibroblast proliferation may be correlated with such variability. The purpose of this paper was to evaluate the association between the risk of developing radiation-induced late xerostomia and four genetic polymorphisms: TGFβ1 C-509T, TGFβ1 T869C, XRCC3 722C>T and ATM 5557G>A in nasopharyngeal carcinoma patients treated with Intensity Modulation Radiated Therapy. The severity of late xerostomia was assessed using a patient self-reported validated xerostomia questionnaire. Polymerase chain reaction-ligation detection reaction methods were performed to determine individual genetic polymorphism. The development of radiation-induced xerostomia associated with genetic polymorphisms was modeled using Cox proportional hazards, accounting for equivalent uniform dose. A total of 43 (41.7%) patients experienced radiation-induced late xerostomia. Univariate Cox proportional hazard analyses showed a higher risk of late xerostomia for patients with XRCC3 722 TT/CT alleles. In multivariate analysis adjusted for clinical and dosimetric factors, XRCC3 722C>T polymorphisms remained a significant factor for higher risk of late xerostomia. To our knowledge, this is the first study that demonstrated an association between genetic polymorphisms and the risk of radiation-induced late xerostomia in nasopharyngeal carcinoma patients treated with Intensity Modulation Radiated Therapy. Our findings suggest that the polymorphisms in XRCC3 are significantly associated with the risk of developing radiation-induced late xerostomia.

  20. Radiation therapy in old patients. Side effects and results of radiation therapy in old patients

    International Nuclear Information System (INIS)

    Geinitz, H.; Zimmermann, F.B.; Molls, M.

    1999-01-01

    Background: Despite a growing number of elderly patients receiving radiation therapy little is known about side effects and outcome of irradiation in this section of the population. Methods: In a review article epidemiologic data, aspects of radiation-biology as well as side effects and outcome of radiation therapy of elderly patients are discussed. Results: Cancer incidence rises with age and is exceeding 3.5% for males older than 85 years. With a life expectancy of more than 4 years, curative therapy is indicated even at this age. Furthermore, several retrospective studies indicate that local control and disease-Specific survival after radiation therapy of elderly patients is comparable with that of younger persons. The exception contains elderly patients with grade-III to IV gliomas or with rectal carcinoma who show a reduced survival which is perhaps caused by less aggressive combined treatment (tumor resection). Although some biological and molecular data indicate a rise in radiation sensitivity with growing age like the reduction of the capacity of some DNA-repair enzymes, there is no convincing evidence in animal studies or in retrospective clinical studies that radiation therapy is generally less well tolerated by older individuals. Some age-depending differences in organ toxicities are described in 3 large studies, which evaluate the data of patients who were enrolled in different EORTC-trials: Older patients suffer more of functional mucositis in case of radiation therapy to the head and neck, they have an increased weight loss and a higher frequency of late esophageal damage when irradiated in the thorax, and they show a higher prevalence of sexual dysfunction when treated with radiation therapy to the pelvis. On the other hand younger patients suffer more from acute toxicity like skin damage, nausea, and deterioration of the performance status during pelvic radiotherapy. When discussing the dose intensity of radiation therapy concomitant disease which

  1. Radiation therapy

    International Nuclear Information System (INIS)

    Peschel, R.E; Fisher, J.J.

    1986-01-01

    The new insights and controversies concerning the radiobiological properties of malignant melanoma and how these relate to new clinical approaches are reviewed. The recent clinical experience with large individual fraction sizes is analyzed. The treatment of malignant melanoma in certain specialized sites is also described. An attempt is made to place in perspective the usefulness of radiation therapy in the treatment of this complex disease. Finally, certain new applications for radiation therapy both alone and in combustion with other treatment modalities are proposed that may ultimately prove appropriate for clinical trials

  2. Dosimetry of ionizing radiation

    International Nuclear Information System (INIS)

    Musilek, L.; Seda, J.; Trousil, J.

    1992-01-01

    The publication deals with a major field of ionizing radiation dosimetry, viz., integrating dosimetric methods, which are the basic means of operative dose determination. It is divided into the following sections: physical and chemical effects of ionizing radiation; integrating dosimetric methods for low radiation doses (film dosimetry, nuclear emulsions, thermoluminescence, radiophotoluminescence, solid-state track detectors, integrating ionization dosemeters); dosimetry of high ionizing radiation doses (chemical dosimetric methods, dosemeters based on the coloring effect, activation detectors); additional methods applicable to integrating dosimetry (exoelectron emission, electron spin resonance, lyoluminescence, etc.); and calibration techniques for dosimetric instrumentation. (Z.S.). 422 refs

  3. Predictive Risk of Radiation Induced Cerebral Necrosis in Pediatric Brain Cancer Patients after VMAT Versus Proton Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Freund, Derek; Zhang, Rui, E-mail: rzhang@marybird.com [Department of Radiation Oncology, Mary Bird Perkins Cancer Center, 4950 Essen Ln., Baton Rouge, LA 70809 (United States); Department of Physics and Astronomy, Louisiana State University, Nicholson Hall, Tower Dr., Baton Rouge, LA 70810 (United States); Sanders, Mary [Department of Radiation Oncology, Mary Bird Perkins Cancer Center, 4950 Essen Ln., Baton Rouge, LA 70809 (United States); Newhauser, Wayne [Department of Radiation Oncology, Mary Bird Perkins Cancer Center, 4950 Essen Ln., Baton Rouge, LA 70809 (United States); Department of Physics and Astronomy, Louisiana State University, Nicholson Hall, Tower Dr., Baton Rouge, LA 70810 (United States)

    2015-04-13

    Cancer of the brain and central nervous system (CNS) is the second most common of all pediatric cancers. Treatment of many of these cancers includes radiation therapy of which radiation induced cerebral necrosis (RICN) can be a severe and potentially devastating side effect. Risk factors for RICN include brain volume irradiated, the dose given per fraction and total dose. Thirteen pediatric patients were selected for this study to determine the difference in predicted risk of RICN when treating with volumetric modulated arc therapy (VMAT) compared to passively scattered proton therapy (PSPT) and intensity modulated proton therapy (IMPT). Plans were compared on the basis of dosimetric endpoints in the planned treatment volume (PTV) and brain and a radiobiological endpoint of RICN calculated using the Lyman-Kutcher-Burman probit model. Uncertainty tests were performed to determine if the predicted risk of necrosis was sensitive to positional errors, proton range errors and selection of risk models. Both PSPT and IMPT plans resulted in a significant increase in the maximum dose to the brain, a significant reduction in the total brain volume irradiated to low doses, and a significant lower predicted risk of necrosis compared with the VMAT plans. The findings of this study were upheld by the uncertainty analysis.

  4. Predictive Risk of Radiation Induced Cerebral Necrosis in Pediatric Brain Cancer Patients after VMAT Versus Proton Therapy

    Directory of Open Access Journals (Sweden)

    Derek Freund

    2015-04-01

    Full Text Available Cancer of the brain and central nervous system (CNS is the second most common of all pediatric cancers. Treatment of many of these cancers includes radiation therapy of which radiation induced cerebral necrosis (RICN can be a severe and potentially devastating side effect. Risk factors for RICN include brain volume irradiated, the dose given per fraction and total dose. Thirteen pediatric patients were selected for this study to determine the difference in predicted risk of RICN when treating with volumetric modulated arc therapy (VMAT compared to passively scattered proton therapy (PSPT and intensity modulated proton therapy (IMPT. Plans were compared on the basis of dosimetric endpoints in the planned treatment volume (PTV and brain and a radiobiological endpoint of RICN calculated using the Lyman-Kutcher-Burman probit model. Uncertainty tests were performed to determine if the predicted risk of necrosis was sensitive to positional errors, proton range errors and selection of risk models. Both PSPT and IMPT plans resulted in a significant increase in the maximum dose to the brain, a significant reduction in the total brain volume irradiated to low doses, and a significant lower predicted risk of necrosis compared with the VMAT plans. The findings of this study were upheld by the uncertainty analysis.

  5. Chemotherapy and molecular target therapy combined with radiation therapy

    International Nuclear Information System (INIS)

    Akimoto, Tetsuo

    2012-01-01

    Combined chemotherapy and radiation therapy has been established as standard treatment approach for locally advanced head and neck cancer, esophageal cancer and so on through randomized clinical trials. However, radiation-related morbidity such as acute toxicity also increased as treatment intensity has increased. In underlining mechanism for enhancement of normal tissue reaction in chemo-radiation therapy, chemotherapy enhanced radiosensitivity of normal tissues in addition to cancer cells. Molecular target-based drugs combined with radiation therapy have been expected as promising approach that makes it possible to achieve cancer-specific enhancement of radiosensitivity, and clinical trials using combined modalities have been performed to evaluate the feasibility and efficacy of this approach. In order to obtain maximum radiotherapeutic gain, a detailed understanding of the mechanism underlying the interaction between radiation and Molecular target-based drugs is indispensable. Among molecular target-based drugs, inhibitors targeting epidermal growth factor receptor (EGFR) and its signal transduction pathways have been vigorously investigated, and mechanisms regarding the radiosensitizing effect have been getting clear. In addition, the results of randomized clinical trials demonstrated that radiation therapy combined with cetuximab resulted in improvement of overall and disease-specific survival rate compared with radiation therapy in locally advanced head and neck cancer. In this review, clinical usefulness of chemo-radiation therapy and potential molecular targets for potentiation of radiation-induced cell killing are summarized. (author)

  6. Determination of the dosimetric properties of ZrO2: Cu and it use in the ultraviolet radiation dosimetry

    International Nuclear Information System (INIS)

    Molina P, D.; Olvera T, L.; Azorin N, J.; Barrera S, M.; Soto E, A.M.; Rivera M, T.

    2006-01-01

    In this work the experimental results of studying the thermoluminescent characteristics (TL) of the zirconium oxide doped with copper (ZrO 2 : Cu) exposed to ultraviolet light of wavelength in the interval of 200-400 nm are presented. The material in powder form was prepared using the sol-gel method. The dosimetric characteristics studied includes the emission curve TL (curved TL), the thermoluminescent response in function of the wavelength, the minimum dose detectable and the lineality of the response. The TL response of the ZrO 2 : Cu in function of the wavelength presents two maxima, in 260 and 290 nm, respectively. The TL curve of the ZrO 2 : Cu showed two peaks, in 120 and 170 C, respectively, being its similar form for all the studied wavelengths. The response in function of the spectral irradiance results to be lineal in the interval from 160 to 2300 mJ/cm 2 . The obtained results when studying the TL properties of ZrO 2 : Cu exposed to the ultraviolet radiation show that it gathers dosimetric characteristics prominent to be used as an ultraviolet radiation dosemeter. (Author)

  7. Dosimetric comparison of stopping power calibration with dual-energy CT and single-energy CT in proton therapy treatment planning

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Jiahua [Department of Physics, University of Adelaide, Adelaide, SA 5005 (Australia); Penfold, Scott N., E-mail: scott.penfold@adelaide.edu.au [Department of Physics, University of Adelaide, Adelaide, SA 5005, Australia and Department of Medical Physics, Royal Adelaide Hospital, Adelaide, SA 5000 (Australia)

    2016-06-15

    Purpose: The accuracy of proton dose calculation is dependent on the ability to correctly characterize patient tissues with medical imaging. The most common method is to correlate computed tomography (CT) numbers obtained via single-energy CT (SECT) with proton stopping power ratio (SPR). CT numbers, however, cannot discriminate between a change in mass density and change in chemical composition of patient tissues. This limitation can have consequences on SPR calibration accuracy. Dual-energy CT (DECT) is receiving increasing interest as an alternative imaging modality for proton therapy treatment planning due to its ability to discriminate between changes in patient density and chemical composition. In the current work we use a phantom of known composition to demonstrate the dosimetric advantages of proton therapy treatment planning with DECT over SECT. Methods: A phantom of known composition was scanned with a clinical SECT radiotherapy CT-simulator. The phantom was rescanned at a lower X-ray tube potential to generate a complimentary DECT image set. A set of reference materials similar in composition to the phantom was used to perform a stoichiometric calibration of SECT CT number to proton SPRs. The same set of reference materials was used to perform a DECT stoichiometric calibration based on effective atomic number. The known composition of the phantom was used to assess the accuracy of SPR calibration with SECT and DECT. Intensity modulated proton therapy (IMPT) treatment plans were generated with the SECT and DECT image sets to assess the dosimetric effect of the imaging modality. Isodose difference maps and root mean square (RMS) error calculations were used to assess dose calculation accuracy. Results: SPR calculation accuracy was found to be superior, on average, with DECT relative to SECT. Maximum errors of 12.8% and 2.2% were found for SECT and DECT, respectively. Qualitative examination of dose difference maps clearly showed the dosimetric advantages

  8. Dosimetric system for measurement of radioactive contaminations

    International Nuclear Information System (INIS)

    Litynski, Z.; Pienkos, J.P.; Witkowski, J.; Zadrozny, S.

    1985-01-01

    A dosimetric system for personnel dosimetry and monitoring measuring a contamination without time delay and dead time is described. The system ensures many-point measurement and minimalization of background radiation influence. 1 fig. (A.S.)

  9. A Study of volumetric modulated arc therapy for stereotactic body radiation therapy in case of multi-target liver cancer using flattening filter free beam

    International Nuclear Information System (INIS)

    Yeom, Mi Sook; Yoon, In Ha; Hong, Dong Gi; Back, Geum Mun

    2015-01-01

    Stereotactic body radiation therapy (SBRT) has proved its efficacy in several patient populations with primary and metastatic limited tumors. Because SBRT prescription is high dose level than Conventional radiation therapy. SBRT plan is necessary for effective Organ at risk (OAR) protection and sufficient Planning target volume (PTV) dose coverage. In particular, multi-target cases may result excessive doses to OAR and hot spot due to dose overlap. This study evaluate usefulness of Volumetric modulated arc therapy (VMAT) in dosimetric and technical considerations using Flattening filter free (FFF) beam. The treatment plans for five patients, being treated on TrueBeam STx(Varian™, USA) with VMAT using 10MV FFF beam and Standard conformal radiotherapy (CRT) using 15MV Flattening filter (FF) beam. PTV, liver, duodenum, bowel, spinal cord, esophagus, stomach dose were evaluated using the dose volume histogram(DVH). Conformity index(CI), homogeneity index(HI), Paddick's index(PCI) for the PTV was assessed. Total Monitor unit (MU) and beam on time was assessed. Average value of CI, HI and PCI for PTV was 1.381±0.028, 1.096±0.016, 0.944±0.473 in VMAT and 1.381± 0.042, 1.136±0.042, 1.534±0.465 in CRT respectively. OAR dose in CRT plans evaluated 1.8 times higher than VMAT. Total MU in VMAT evaluated 1.3 times increase than CRT. Average beam on time was 6.8 minute in VMAT and 21.3 minute in CRT respectively. OAR dose in CRT plans evaluated 1.8 times higher than VMAT. Total MU in VMAT evaluated 1.3 times increase than CRT. Average beam on time was 6.8 minute in VMAT and 21.3 minute in CRT. VMAT for SBRT in multi-target liver cancer using FFF beam is effective treatment techniqe in dosimetric and technical considerations. VMAT decrease intra-fraction error due to treatment time shortening using high dose rate of FFF beam

  10. A Study of volumetric modulated arc therapy for stereotactic body radiation therapy in case of multi-target liver cancer using flattening filter free beam

    Energy Technology Data Exchange (ETDEWEB)

    Yeom, Mi Sook; Yoon, In Ha; Hong, Dong Gi; Back, Geum Mun [Dept. of Radiation Oncology, ASAN Medical Center, Seoul (Korea, Republic of)

    2015-06-15

    Stereotactic body radiation therapy (SBRT) has proved its efficacy in several patient populations with primary and metastatic limited tumors. Because SBRT prescription is high dose level than Conventional radiation therapy. SBRT plan is necessary for effective Organ at risk (OAR) protection and sufficient Planning target volume (PTV) dose coverage. In particular, multi-target cases may result excessive doses to OAR and hot spot due to dose overlap. This study evaluate usefulness of Volumetric modulated arc therapy (VMAT) in dosimetric and technical considerations using Flattening filter free (FFF) beam. The treatment plans for five patients, being treated on TrueBeam STx(Varian™, USA) with VMAT using 10MV FFF beam and Standard conformal radiotherapy (CRT) using 15MV Flattening filter (FF) beam. PTV, liver, duodenum, bowel, spinal cord, esophagus, stomach dose were evaluated using the dose volume histogram(DVH). Conformity index(CI), homogeneity index(HI), Paddick's index(PCI) for the PTV was assessed. Total Monitor unit (MU) and beam on time was assessed. Average value of CI, HI and PCI for PTV was 1.381±0.028, 1.096±0.016, 0.944±0.473 in VMAT and 1.381± 0.042, 1.136±0.042, 1.534±0.465 in CRT respectively. OAR dose in CRT plans evaluated 1.8 times higher than VMAT. Total MU in VMAT evaluated 1.3 times increase than CRT. Average beam on time was 6.8 minute in VMAT and 21.3 minute in CRT respectively. OAR dose in CRT plans evaluated 1.8 times higher than VMAT. Total MU in VMAT evaluated 1.3 times increase than CRT. Average beam on time was 6.8 minute in VMAT and 21.3 minute in CRT. VMAT for SBRT in multi-target liver cancer using FFF beam is effective treatment techniqe in dosimetric and technical considerations. VMAT decrease intra-fraction error due to treatment time shortening using high dose rate of FFF beam.

  11. WE-AB-209-12: Quasi Constrained Multi-Criteria Optimization for Automated Radiation Therapy Treatment Planning

    Energy Technology Data Exchange (ETDEWEB)

    Watkins, W.T.; Siebers, J.V. [University of Virginia, Charlottesville, VA (United States)

    2016-06-15

    Purpose: To introduce quasi-constrained Multi-Criteria Optimization (qcMCO) for unsupervised radiation therapy optimization which generates alternative patient-specific plans emphasizing dosimetric tradeoffs and conformance to clinical constraints for multiple delivery techniques. Methods: For N Organs At Risk (OARs) and M delivery techniques, qcMCO generates M(N+1) alternative treatment plans per patient. Objective weight variations for OARs and targets are used to generate alternative qcMCO plans. For 30 locally advanced lung cancer patients, qcMCO plans were generated for dosimetric tradeoffs to four OARs: each lung, heart, and esophagus (N=4) and 4 delivery techniques (simple 4-field arrangements, 9-field coplanar IMRT, 27-field non-coplanar IMRT, and non-coplanar Arc IMRT). Quasi-constrained objectives included target prescription isodose to 95% (PTV-D95), maximum PTV dose (PTV-Dmax)< 110% of prescription, and spinal cord Dmax<45 Gy. The algorithm’s ability to meet these constraints while simultaneously revealing dosimetric tradeoffs was investigated. Statistically significant dosimetric tradeoffs were defined such that the coefficient of determination between dosimetric indices which varied by at least 5 Gy between different plans was >0.8. Results: The qcMCO plans varied mean dose by >5 Gy to ipsilateral lung for 24/30 patients, contralateral lung for 29/30 patients, esophagus for 29/30 patients, and heart for 19/30 patients. In the 600 plans computed without human interaction, average PTV-D95=67.4±3.3 Gy, PTV-Dmax=79.2±5.3 Gy, and spinal cord Dmax was >45 Gy in 93 plans (>50 Gy in 2/600 plans). Statistically significant dosimetric tradeoffs were evident in 19/30 plans, including multiple tradeoffs of at least 5 Gy between multiple OARs in 7/30 cases. The most common statistically significant tradeoff was increasing PTV-Dmax to reduce OAR dose (15/30 patients). Conclusion: The qcMCO method can conform to quasi-constrained objectives while revealing

  12. WE-AB-209-12: Quasi Constrained Multi-Criteria Optimization for Automated Radiation Therapy Treatment Planning

    International Nuclear Information System (INIS)

    Watkins, W.T.; Siebers, J.V.

    2016-01-01

    Purpose: To introduce quasi-constrained Multi-Criteria Optimization (qcMCO) for unsupervised radiation therapy optimization which generates alternative patient-specific plans emphasizing dosimetric tradeoffs and conformance to clinical constraints for multiple delivery techniques. Methods: For N Organs At Risk (OARs) and M delivery techniques, qcMCO generates M(N+1) alternative treatment plans per patient. Objective weight variations for OARs and targets are used to generate alternative qcMCO plans. For 30 locally advanced lung cancer patients, qcMCO plans were generated for dosimetric tradeoffs to four OARs: each lung, heart, and esophagus (N=4) and 4 delivery techniques (simple 4-field arrangements, 9-field coplanar IMRT, 27-field non-coplanar IMRT, and non-coplanar Arc IMRT). Quasi-constrained objectives included target prescription isodose to 95% (PTV-D95), maximum PTV dose (PTV-Dmax)< 110% of prescription, and spinal cord Dmax<45 Gy. The algorithm’s ability to meet these constraints while simultaneously revealing dosimetric tradeoffs was investigated. Statistically significant dosimetric tradeoffs were defined such that the coefficient of determination between dosimetric indices which varied by at least 5 Gy between different plans was >0.8. Results: The qcMCO plans varied mean dose by >5 Gy to ipsilateral lung for 24/30 patients, contralateral lung for 29/30 patients, esophagus for 29/30 patients, and heart for 19/30 patients. In the 600 plans computed without human interaction, average PTV-D95=67.4±3.3 Gy, PTV-Dmax=79.2±5.3 Gy, and spinal cord Dmax was >45 Gy in 93 plans (>50 Gy in 2/600 plans). Statistically significant dosimetric tradeoffs were evident in 19/30 plans, including multiple tradeoffs of at least 5 Gy between multiple OARs in 7/30 cases. The most common statistically significant tradeoff was increasing PTV-Dmax to reduce OAR dose (15/30 patients). Conclusion: The qcMCO method can conform to quasi-constrained objectives while revealing

  13. Realisation of dosimetric studies for workplaces with a risk of exposure to ionizing radiations (version 2). Practical guide

    International Nuclear Information System (INIS)

    Donadille, L.; Rehel, J.L.; Deligne, J.M.; Queinnec, F.; Aubert, B.; Bottollier-Depois, J.F.; Clairand, I.; Jourdain, J.R.; Rannou, A.

    2010-01-01

    This guide proposes a methodological approach to help carry out dosimetric workplace studies complying with the french regulation, and necessary to identify risks of radiological exposure, optimize radiation protection, classify the workers into different categories and the workplaces into different areas. Additional information is provided relating the main objectives of a workplace study, the French regulatory context, main sources and pathways of exposure to ionizing radiation. Radiation protection and operational quantities are reminded. Recommendations about the selection and use of detectors and about the implementation of calculation methods are also provided. The general methodological approach is applied and developed into 'workplace sheets', each one devoted to a particular type of workplace. (authors)

  14. Study on external beam radiation therapy

    International Nuclear Information System (INIS)

    Kim, Mi Sook; Yoo, Seoung Yul; Yoo, Hyung Jun; Ji, Young Hoon; Lee, Dong Han; Lee, Dong Hoon; Choi, Mun Sik; Yoo, Dae Heon; Lee, Hyo Nam; Kim, Kyeoung Jung

    1999-04-01

    To develop the therapy technique which promote accuracy and convenience in external radiation therapy, to obtain the development of clinical treatment methods for the global competition. The contents of the R and D were 1. structure, process and outcome analysis in radiation therapy department. 2. Development of multimodality treatment in radiation therapy 3. Development of computation using networking techniques 4. Development of quality assurance (QA) system in radiation therapy 5. Development of radiotherapy tools 6. Development of intraoperative radiation therapy (IORT) tools. The results of the R and D were 1. completion of survey and analysis about Korea radiation therapy status 2. Performing QA analysis about ICR on cervix cancer 3. Trial of multicenter randomized study on lung cancers 4. Setting up inter-departmental LAN using MS NT server and Notes program 5. Development of ionization chamber and dose-rate meter for QA in linear accelerator 6. Development on optimized radiation distribution algorithm for multiple slice 7. Implementation on 3 dimensional volume surface algorithm and 8. Implementation on adaptor and cone for IORT

  15. Study on external beam radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Mi Sook; Yoo, Seoung Yul; Yoo, Hyung Jun; Ji, Young Hoon; Lee, Dong Han; Lee, Dong Hoon; Choi, Mun Sik; Yoo, Dae Heon; Lee, Hyo Nam; Kim, Kyeoung Jung

    1999-04-01

    To develop the therapy technique which promote accuracy and convenience in external radiation therapy, to obtain the development of clinical treatment methods for the global competition. The contents of the R and D were 1. structure, process and outcome analysis in radiation therapy department. 2. Development of multimodality treatment in radiation therapy 3. Development of computation using networking techniques 4. Development of quality assurance (QA) system in radiation therapy 5. Development of radiotherapy tools 6. Development of intraoperative radiation therapy (IORT) tools. The results of the R and D were 1. completion of survey and analysis about Korea radiation therapy status 2. Performing QA analysis about ICR on cervix cancer 3. Trial of multicenter randomized study on lung cancers 4. Setting up inter-departmental LAN using MS NT server and Notes program 5. Development of ionization chamber and dose-rate meter for QA in linear accelerator 6. Development on optimized radiation distribution algorithm for multiple slice 7. Implementation on 3 dimensional volume surface algorithm and 8. Implementation on adaptor and cone for IORT.

  16. Radiation therapy for operable rectal cancer

    International Nuclear Information System (INIS)

    Bondar, G.V.; Semikoz, N.G.; Bashejev, V.Kh.; Borota, O.V.; Bondarenko, M.V.; Kiyashko, O.Yu.

    2012-01-01

    The authors present a review of the literature on modern tendencies of radiation therapy application to treatment of operable rectal cancer. Many randomized control studies compared the efficacy of combination of radiation therapy (pre-operative or post-operative) and surgery versus surgery only demonstrating various results. Meta-analysis of the data on efficacy of combination of radiation therapy and standard surgery revealed 22 randomized control studies (14 with pre-operative radiation therapy and 8 with post-operative radiation therapy) with total number of 8507 patients (Colorectal Cancer Collaborative Group, 2000). The use of combination treatment reduced the number of isolated locoregional relapses both with pre-operative (22.5 - 12.5 %; p < 0.00001) and post-operative radiation therapy (25.8 - 16.7 %; p - 0.00001). The influence on total survival was not significant (62 % vs. 63 %; p - 0.06).

  17. Job satisfaction among radiation therapy educators.

    Science.gov (United States)

    Swafford, Larry G; Legg, Jeffrey S

    2007-01-01

    Job satisfaction is one of the most consistent variables related to employee retention and is especially relevant considering the shortage of radiation therapists and radiation therapy educators in the United States. To investigate job satisfaction levels among radiation therapy educators certified by the American Registry of Radiologic Technologists and employed in programs accredited by the Joint Review Committee on Education in Radiologic Technology. The long form of the Minnesota Satisfaction Questionnaire (MSQ) was mailed to 158 radiation therapy educators to measure job satisfaction. Overall job satisfaction and subscales were calculated based on MSQ methodology. A total of 90 usable surveys were returned for a 56.9% response rate. With a "general satisfaction" score of 69.64, radiation therapy educators ranked in the lowest 25th percentile of the nondisabled norm scale for job satisfaction. Respondents reported higher degrees of job satisfaction on the moral values, social service and achievement subscales. Lower job satisfaction levels were associated with the company policies and practices, advancement and compensation subscales. Radiation therapy educators report low job satisfaction. Educational institutions must tailor recruitment and retention efforts to better reflect the positive aspects of being a radiation therapy educator. Furthermore, improving retention and recruitment efforts might help offset the current shortages of radiation therapy educators and, ultimately, clinical radiation therapists.

  18. Computational model for dosimetric purposes in dental procedures

    International Nuclear Information System (INIS)

    Kawamoto, Renato H.; Campos, Tarcisio R.

    2013-01-01

    This study aims to develop a computational model for dosimetric purposes the oral region, based on computational tools SISCODES and MCNP-5, to predict deterministic effects and minimize stochastic effects caused by ionizing radiation by radiodiagnosis. Based on a set of digital information provided by computed tomography, three-dimensional voxel model was created, and its tissues represented. The model was exported to the MCNP code. In association with SICODES, we used the Monte Carlo N-Particle Transport Code (MCNP-5) method to play the corresponding interaction of nuclear particles with human tissues statistical process. The study will serve as a source of data for dosimetric studies in the oral region, providing deterministic effect and minimize the stochastic effect of ionizing radiation

  19. Predicting Nonauditory Adverse Radiation Effects Following Radiosurgery for Vestibular Schwannoma: A Volume and Dosimetric Analysis

    International Nuclear Information System (INIS)

    Hayhurst, Caroline; Monsalves, Eric; Bernstein, Mark; Gentili, Fred; Heydarian, Mostafa; Tsao, May; Schwartz, Michael; Prooijen, Monique van; Millar, Barbara-Ann; Ménard, Cynthia; Kulkarni, Abhaya V.; Laperriere, Norm; Zadeh, Gelareh

    2012-01-01

    Purpose: To define clinical and dosimetric predictors of nonauditory adverse radiation effects after radiosurgery for vestibular schwannoma treated with a 12 Gy prescription dose. Methods: We retrospectively reviewed our experience of vestibular schwannoma patients treated between September 2005 and December 2009. Two hundred patients were treated at a 12 Gy prescription dose; 80 had complete clinical and radiological follow-up for at least 24 months (median, 28.5 months). All treatment plans were reviewed for target volume and dosimetry characteristics; gradient index; homogeneity index, defined as the maximum dose in the treatment volume divided by the prescription dose; conformity index; brainstem; and trigeminal nerve dose. All adverse radiation effects (ARE) were recorded. Because the intent of our study was to focus on the nonauditory adverse effects, hearing outcome was not evaluated in this study. Results: Twenty-seven (33.8%) patients developed ARE, 5 (6%) developed hydrocephalus, 10 (12.5%) reported new ataxia, 17 (21%) developed trigeminal dysfunction, 3 (3.75%) had facial weakness, and 1 patient developed hemifacial spasm. The development of edema within the pons was significantly associated with ARE (p = 0.001). On multivariate analysis, only target volume is a significant predictor of ARE (p = 0.001). There is a target volume threshold of 5 cm3, above which ARE are more likely. The treatment plan dosimetric characteristics are not associated with ARE, although the maximum dose to the 5th nerve is a significant predictor of trigeminal dysfunction, with a threshold of 9 Gy. The overall 2-year tumor control rate was 96%. Conclusions: Target volume is the most important predictor of adverse radiation effects, and we identified the significant treatment volume threshold to be 5 cm3. We also established through our series that the maximum tolerable dose to the 5th nerve is 9 Gy.

  20. Predicting Nonauditory Adverse Radiation Effects Following Radiosurgery for Vestibular Schwannoma: A Volume and Dosimetric Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Hayhurst, Caroline; Monsalves, Eric; Bernstein, Mark; Gentili, Fred [Gamma Knife Unit, Division of Neurosurgery, University Health Network, Toronto (Canada); Heydarian, Mostafa; Tsao, May [Radiation Medicine Program, Princess Margaret Hospital, Toronto (Canada); Schwartz, Michael [Radiation Oncology Program and Division of Neurosurgery, Sunnybrook Hospital, Toronto (Canada); Prooijen, Monique van [Radiation Medicine Program, Princess Margaret Hospital, Toronto (Canada); Millar, Barbara-Ann; Menard, Cynthia [Radiation Oncology Program, Princess Margaret Hospital, Toronto (Canada); Kulkarni, Abhaya V. [Division of Neurosurgery, Hospital for Sick Children, University of Toronto (Canada); Laperriere, Norm [Radiation Oncology Program, Princess Margaret Hospital, Toronto (Canada); Zadeh, Gelareh, E-mail: Gelareh.Zadeh@uhn.on.ca [Gamma Knife Unit, Division of Neurosurgery, University Health Network, Toronto (Canada)

    2012-04-01

    Purpose: To define clinical and dosimetric predictors of nonauditory adverse radiation effects after radiosurgery for vestibular schwannoma treated with a 12 Gy prescription dose. Methods: We retrospectively reviewed our experience of vestibular schwannoma patients treated between September 2005 and December 2009. Two hundred patients were treated at a 12 Gy prescription dose; 80 had complete clinical and radiological follow-up for at least 24 months (median, 28.5 months). All treatment plans were reviewed for target volume and dosimetry characteristics; gradient index; homogeneity index, defined as the maximum dose in the treatment volume divided by the prescription dose; conformity index; brainstem; and trigeminal nerve dose. All adverse radiation effects (ARE) were recorded. Because the intent of our study was to focus on the nonauditory adverse effects, hearing outcome was not evaluated in this study. Results: Twenty-seven (33.8%) patients developed ARE, 5 (6%) developed hydrocephalus, 10 (12.5%) reported new ataxia, 17 (21%) developed trigeminal dysfunction, 3 (3.75%) had facial weakness, and 1 patient developed hemifacial spasm. The development of edema within the pons was significantly associated with ARE (p = 0.001). On multivariate analysis, only target volume is a significant predictor of ARE (p = 0.001). There is a target volume threshold of 5 cm3, above which ARE are more likely. The treatment plan dosimetric characteristics are not associated with ARE, although the maximum dose to the 5th nerve is a significant predictor of trigeminal dysfunction, with a threshold of 9 Gy. The overall 2-year tumor control rate was 96%. Conclusions: Target volume is the most important predictor of adverse radiation effects, and we identified the significant treatment volume threshold to be 5 cm3. We also established through our series that the maximum tolerable dose to the 5th nerve is 9 Gy.

  1. Dosimetric response evaluation of tooth enamel for accelerator-based neutron radiation

    International Nuclear Information System (INIS)

    Khan, R.F.H.; Rink, W.J.; Boreham, D.R.

    2003-01-01

    To study the neutron response of human tooth enamel, a number of experiments with an accelerator-based neutron source have been designed. The neutron beam was produced with the low gamma yield, 7 Li(p,n) 7 Be type thick target, using the 3 MV McMaster K.N. Van de Graaff accelerator. The dosimetry was done using a pre-calibrated snoopy type neutron dosimeter. Neutron irradiation induces a dosimetric signal in the tooth enamel at the same defect site as gamma produced damage with the same g-values (g parallel =1.9973, width 0.4 mT g perpendicular =2.002, width 0.3 mT). The dosimetric signal grows linearly with neutron dose from 6-35 Gy tissue dose. Dosimetric response in two different grain sizes (300-500 μm, and grains <4 mm) has shown increased dosimetric amplitude in the larger grains. Dose build up effect on tooth inside the mouth due to cheek was simulated by placing a 4 mm thick paraffin wax layer between the beam and tooth, but had little effect. These results show that for mean neutron energy of 280 keV, the relative neutron response of the human tooth enamel ranges from 8% to 12% of the equivalent gamma ray response

  2. Study of dosimetric systems-ferrous sulfate-ferric sulfate, glass slides and dyed aqueous solutions

    International Nuclear Information System (INIS)

    Fernandes, L.

    1979-01-01

    The effect of some variables which can effect the preparation of the ferrous sulfate used as dosimetric solution has been studied. Among these variables the purity of the water used for the preparation of the solution and the presence (or absence) of oxygen in the dosimetric solution were considered. The dose rate distribution according to the transverse and longitudinal sections of the Co 60 irradiator was studied experimentally, using the dosimetric solution, and theoretically, using a computer program (KIFE). The results obtained with the ferrous sulface dosimetric solution were used as reference for the study of the application of EM and MSG glass slide as a dosimetric system. For this purpose the effects of the weakening of the coloration induced in the glass by gamma rays (Co 60 ) and the relationship between the absorbed dose of radiation and the ratio between the variation in absorbation value and the thickness of the glass irradiated, were studied. A study was also made of the use of the dye indicators bromothymol-blue, methyl-orange, Congo-red, neutral-red and p-nitrophenol, in aqueous solution, for radiation dose measurements. The bleaching of each indicator solution, under gamma-radiation (Co 60 ) was studied in oxygen and nitrogen atmospheres.(Author) [pt

  3. Correlation between gamma index passing rate and clinical dosimetric difference for pre-treatment 2D and 3D volumetric modulated arc therapy dosimetric verification.

    Science.gov (United States)

    Jin, X; Yan, H; Han, C; Zhou, Y; Yi, J; Xie, C

    2015-03-01

    To investigate comparatively the percentage gamma passing rate (%GP) of two-dimensional (2D) and three-dimensional (3D) pre-treatment volumetric modulated arc therapy (VMAT) dosimetric verification and their correlation and sensitivity with percentage dosimetric errors (%DE). %GP of 2D and 3D pre-treatment VMAT quality assurance (QA) with different acceptance criteria was obtained by ArcCHECK® (Sun Nuclear Corporation, Melbourne, FL) for 20 patients with nasopharyngeal cancer (NPC) and 20 patients with oesophageal cancer. %DE were calculated from planned dose-volume histogram (DVH) and patients' predicted DVH calculated by 3DVH® software (Sun Nuclear Corporation). Correlation and sensitivity between %GP and %DE were investigated using Pearson's correlation coefficient (r) and receiver operating characteristics (ROCs). Relatively higher %DE on some DVH-based metrics were observed for both patients with NPC and oesophageal cancer. Except for 2%/2 mm criterion, the average %GPs for all patients undergoing VMAT were acceptable with average rates of 97.11% ± 1.54% and 97.39% ± 1.37% for 2D and 3D 3%/3 mm criteria, respectively. The number of correlations for 3D was higher than that for 2D (21 vs 8). However, the general correlation was still poor for all the analysed metrics (9 out of 26 for 3D 3%/3 mm criterion). The average area under the curve (AUC) of ROCs was 0.66 ± 0.12 and 0.71 ± 0.21 for 2D and 3D evaluations, respectively. There is a lack of correlation between %GP and %DE for both 2D and 3D pre-treatment VMAT dosimetric evaluation. DVH-based dose metrics evaluation obtained from 3DVH will provide more useful analysis. Correlation and sensitivity of %GP with %DE for VMAT QA were studied for the first time.

  4. SU-E-J-165: Dosimetric Impact of Liver Rotations in Stereotactic Body Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Pinnaduwage, D; Paulsson, A; Sudhyadhom, A; Chen, J; Chang, A; Anwar, M; Gottschalk, A; Yom, S S.; Descovich, M [University of California San Francisco, San Francisco, CA (United States)

    2015-06-15

    Purpose: Often in liver stereotactic body radiotherapy a single fiducial is implanted near the tumor for image-guided treatment delivery. In such cases, rotational corrections are calculated based on the spine. This study quantifies rotational differences between the spine and liver, and investigates the corresponding dosimetric impact. Methods: Seven patients with 3 intrahepatic fiducials and 4DCT scans were identified. The planning CT was separately co-registered with 4 phases of the 4DCT (0%, 50%, 100% inhale and 50% exhale) by 1) rigid registration of the spine, and 2) point-based registration of the 3 fiducials. Rotation vectors were calculated for each registration. Translational differences in fiducial positions between the 2 registrations methods were investigated. Dosimetric impact due to liver rotations and deformations was assessed using critical structures delineated on the 4DCT phases. For dose comparisons, a single fiducial was translationally aligned following spine alignment to represent what is typically done in the clinic. Results: On average, differences between spine and liver rotations during the 0%, 50%, 100% inhale, and 50% exhale phases were 3.23°, 3.27°, 2.26° and 3.11° (pitch), 3.00°, 2.24°, 3.12° and 1.73° (roll), and 1.57°, 1.98°, 2.09° and 1.36° (yaw), respectively. The maximum difference in rotations was 12°, with differences of >3° seen in 14/28 (pitch), 10/28 (roll), and 6/28 (yaw) cases. Average fiducial displacements of 2.73 (craniocaudal), 1.04 (lateral) and 1.82 mm (vertical) were seen. Evaluating percent dose differences for 5 patients at the peaks of the respiratory cycle, the maximum dose to the duodenum, stomach, bowel and esophagus differed on average by 11.4%, 5.3%, 11.2% and 49.1% between the 2 registration methods. Conclusion: Lack of accounting for liver rotation during treatment might Result in clinically significant dose differences to critical structures. Both rotational and translational deviations

  5. Basal cell carcinoma after radiation therapy

    International Nuclear Information System (INIS)

    Shimbo, Keisuke; Terashi, Hiroto; Ishida, Yasuhisa; Tahara, Shinya; Osaki, Takeo; Nomura, Tadashi; Ejiri, Hirotaka

    2008-01-01

    We reported two cases of basal cell carcinoma (BCC) that developed after radiation therapy. A 50-year-old woman, who had received an unknown amount of radiation therapy for the treatment of intracranial germinoma at the age of 22, presented with several tumors around the radiation ulcer. All tumors showed BCC. A 33-year-old woman, who had received an unknown amount of radiation therapy on the head for the treatment of leukemia at the age of 2, presented with a black nodule within the area of irradiation. The tumor showed BCC. We discuss the occurrence of BCC after radiation therapy. (author)

  6. Dosimetric comparison to the heart and cardiac substructure in a large cohort of esophageal cancer patients treated with proton beam therapy or Intensity-modulated radiation therapy.

    Science.gov (United States)

    Shiraishi, Yutaka; Xu, Cai; Yang, Jinzhong; Komaki, Ritsuko; Lin, Steven H

    2017-10-01

    To compare heart and cardiac substructure radiation exposure using intensity-modulated radiotherapy (IMRT) vs. proton beam therapy (PBT) for patients with mid- to distal esophageal cancer who received chemoradiation therapy. We identified 727 esophageal cancer patients who received IMRT (n=477) or PBT (n=250) from March 2004 to December 2015. All patients were treated to 50.4Gy with IMRT or to 50.4 cobalt Gray equivalents with PBT. IMRT and PBT dose-volume histograms (DVHs) of the whole heart, atria, ventricles, and four coronary arteries were compared. For PBT patients, passive scattering proton therapy (PSPT; n=237) and intensity-modulated proton therapy (IMPT; n=13) DVHs were compared. Compared with IMRT, PBT resulted in significantly lower mean heart dose (MHD) and heart V5, V10, V20, V30, and V40as well as lower radiation exposure to the four chambers and four coronary arteries. Compared with PSPT, IMPT resulted in significantly lower heart V20, V30, and V40 but not MHD or heart V5 or V10. IMPT also resulted in significantly lower radiation doses to the left atrium, right atrium, left main coronary artery, and left circumflex artery, but not the left ventricle, right ventricle, left anterior descending artery, or right coronary artery. Factors associated with lower MHD included PBT (Pheart and cardiac substructures than IMRT. Long-term studies are necessary to determine how this cardiac sparing effect impacts the development of coronary artery disease and other cardiac complications. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Technical advances in radiation therapy

    International Nuclear Information System (INIS)

    Sause, W.T.

    1986-01-01

    Substantial advances have been made in radiation therapy. Many of these advances can be applied in most radiation therapy departments without expensive improvements in equipment. Changes in radiation fractionation, chemotherapeutic sensitization, intraoperative radiation, and interstitial implants can be performed with experience and improved physician training in most medium-sized departments. Advances that require investments in expensive equipment such as particle radiation and hyperthermia will need to be evaluated at designated treatment centers. 106 references

  8. A Comparison of Helical Intensity-Modulated Radiotherapy, Intensity-Modulated Radiotherapy, and 3D-Conformal Radiation Therapy for Pancreatic Cancer

    International Nuclear Information System (INIS)

    Poppe, Matthew M.; Narra, Venkat; Yue, Ning J.; Zhou Jinghao; Nelson, Carl; Jabbour, Salma K.

    2011-01-01

    We assessed dosimetric differences in pancreatic cancer radiotherapy via helical intensity-modulated radiotherapy (HIMRT), linac-based IMRT, and 3D-conformal radiation therapy (3D-CRT) with regard to successful plan acceptance and dose to critical organs. Dosimetric analysis was performed in 16 pancreatic cases that were planned to 54 Gy; both post-pancreaticoduodenectomy (n = 8) and unresected (n = 8) cases were compared. Without volume modification, plans met constraints 75% of the time with HIMRT and IMRT and 13% with 3D-CRT. There was no statistically significantly improvement with HIMRT over conventional IMRT in reducing liver V35, stomach V45, or bowel V45. HIMRT offers improved planning target volume (PTV) dose homogeneity compared with IMRT, averaging a lower maximum dose and higher volume receiving the prescription dose (D100). HIMRT showed an increased mean dose over IMRT to bowel and liver. Both HIMRT and IMRT offer a statistically significant improvement over 3D-CRT in lowering dose to liver, stomach, and bowel. The results were similar for both unresected and resected patients. In pancreatic cancer, HIMRT offers improved dose homogeneity over conventional IMRT and several significant benefits to 3D-CRT. Factors to consider before incorporating IMRT into pancreatic cancer therapy are respiratory motion, dose inhomogeneity, and mean dose.

  9. Radiation therapy sources, equipment and installations

    International Nuclear Information System (INIS)

    2011-03-01

    The safety code for Telegamma Therapy Equipment and Installations, (AERB/SC/MED-1) and safety code for Brachytherapy Sources, Equipment and Installations, (AERB/SC/MED-3) were issued by AERB in 1986 and 1988 respectively. These codes specified mandatory requirements for radiation therapy facilities, covering the entire spectrum of operations ranging from the setting up of a facility to its ultimate decommissioning, including procedures to be followed during emergency situations. The codes also stipulated requirements of personnel and their responsibilities. With the advent of new techniques and equipment such as 3D-conformal radiation therapy, intensity modulated radiation therapy, image guided radiation therapy, treatment planning system, stereotactic radiosurgery, stereotactic radiotherapy, portal imaging, integrated brachytherapy and endovascular brachytherapy during the last two decades, AERB desires that these codes be revised and merged into a single code titled Radiation Therapy Sources, Equipment, and Installations

  10. Validation of intensity modulated radiation therapy patient plans with portal images

    International Nuclear Information System (INIS)

    Delpon, G.; Warren, S.; Mahe, D.; Gaudaire, S.; Lisbona, A.

    2007-01-01

    The goal of this study was to show the feasibility of step and shoot intensity-modulated radiation therapy pre-treatment quality control for patients using the electronic portal imaging device (iViewGT) fitted on a Sli+ linac (Elekta Oncology Systems, Crawley, UK) instead of radiographic films. Since the beginning of intensity-modulated radiation therapy treatments, the dosimetric quality control necessary before treating each new patient has been a time-consuming and therefore costly obligation. In order to fully develop this technique, it seems absolutely essential to reduce the cost of these controls, especially the linac time. Up to now, verification of the relative dosimetry field by field has been achieved by acquiring radiographic films in the isocenter plane and comparing them to the results of the XiO planning system (Computerized Medical Systems, Missouri, USA) using RIT113 v4.1 software (Radiological Imaging Technology, Colorado, USA). A qualitative and quantitative evaluation was realised for every field of every patient. A quick and simple procedure was put into place to be able to make the same verifications using portal images. This new technique is not a modification of the overall methodology of analysis. The results achieved by comparing the measurement with the electronic portal imaging device and the calculation with the treatment planning system were in line with those achieved with the films for all indicators we studied (isodoses, horizontal and vertical dose profiles and gamma index). (authors)

  11. Radiation Therapy Side Effects

    Science.gov (United States)

    Radiation therapy has side effects because it not only kills or slows the growth of cancer cells, it can also affect nearby healthy cells. Many people who get radiation therapy experience fatigue. Other side effects depend on the part of the body that is being treated. Learn more about possible side effects.

  12. Internal Radiation Therapy for Cancer

    Science.gov (United States)

    When getting internal radiation therapy, a source of radiation is put inside your body, in either liquid or solid form. It can be used treat different kinds of cancer, including thyroid, head and neck, breast, cervix, prostate, and eye. Learn more about how what to expect when getting internal radiation therapy.

  13. Nonsurgical treatment for cancer using radiation therapy

    International Nuclear Information System (INIS)

    Ogi, Yasuo

    2012-01-01

    The number of people who are dying from cancer has been increasing in association with population aging. Radiation therapy is now one of the three major cancer treatment methods, along with surgery and chemotherapy. People used to consider radiation therapy only as a ''noninvasive cancer treatment''; however, with the ceaseless effort by medical experts and corporations, different radiation therapy types and techniques including the latest technical advances have come out one after another, and the improvements in radiation therapies have provided treatments that are not only less traumatizing to patients but also as effective and therapeutic as surgery in certain body regions. The importance of radiation therapy has become and will become even greater in the society with more elderly cancer patients who do not have the physical strength to undergo surgery. In this article, the history of radiation therapy, rapidly developed high-precision radiation therapy techniques, and unsolved issues are discussed, and then, ''MHI vero4DRT'', which is the high-precision image-guided radiation therapy equipment developed for solving such issues, is introduced. (author)

  14. Dosimetric impact of mixed-energy volumetric modulated arc therapy plans for high-risk prostate cancer

    Directory of Open Access Journals (Sweden)

    Shyam Pokharel

    2013-10-01

    Full Text Available Purpose: This study investigated the dosimetric impact of mixing low and high energy treatment plans for prostate cancer treated with volumetric modulated arc therapy (VMAT technique in the form of RapidArc.Methods: A cohort of 12 prostate cases involving proximal seminal vesicles and lymph nodes was selected for this retrospective study. For each prostate case, the single-energy plans (SEPs and mixed-energy plans (MEPs were generated.  First, the SEPs were created using 6 mega-voltage (MV energy for both the primary and boost plans. Second, the MEPs were created using 16 MV energy for the primary plan and 6 MV energy for the boost plan. The primary and boost MEPs used identical beam parameters and same dose optimization values as in the primary and boost SEPs for the corresponding case. The dosimetric parameters from the composite plans (SEPs and MEPs were evaluated. Results: The dose to the target volume was slightly higher (on average <1% in the SEPs than in the MEPs. The conformity index (CI and homogeneity index (HI values between the SEPs and MEPs were comparable. The dose to rectum and bladder was always higher in the SEPs (average difference up to 3.7% for the rectum and up to 8.4% for the bladder than in the MEPs. The mean dose to femoral heads was higher by about 0.8% (on average in the MEPs than in the SEPs. The number of monitor units and integral dose were higher in the SEPs compared to the MEPs by average differences of 9.1% and 5.5%, respectively.Conclusion: The preliminary results from this study suggest that use of mixed-energy VMAT plan for high-risk prostate cancer could potentially reduce the integral dose and minimize the dose to rectum and bladder, but for the higher femoral head dose.-----------------------------------------------Cite this article as:Pokharel S. Dosimetric impact of mixed-energy volumetric modulated arc therapy plans for high-risk prostate cancer. Int J Cancer Ther Oncol 2013;1(1:01011.DOI: http

  15. SU-F-P-11: Long Term Dosimetric Stability of 6 TomoTherapy Systems

    Energy Technology Data Exchange (ETDEWEB)

    Smilowitz, J; Dunkerley, D; Geurts, M; Hill, P; Yadav, P [University of Wisconsin, Madison, WI (United States)

    2016-06-15

    Purpose: The dosimetric stability of six TomoTherapy units was analyzed to investigate changes in performance over time and with system upgrades. Methods: Energy and output were tracked using monitor chamber signal, onboard MVCT detector signal and external ion chamber measurements. The systems (and monitoring periods) include 3 Hi-Art (67, 61 and 65 mos.), 2 HDA (29 and 25 mos.) and one research unit (7 mo.). Dose Control Stability system (DCS) was installed on 4 systems. Output stability is reported as deviation from reference monitor chamber signal for all systems, and from an external chamber for 4 systems. Energy stability was monitored using the relative (center versus off-axis) MVCT detector signal and/or the ratio of chamber measurements at 2 depths. The results from the clinical systems were used to benchmark the stability of the research unit, which has the same linear accelerator but runs at a higher dose rate. Results: The output based on monitor chamber data of all six systems is very stable. Non- DCS had a standard deviation of 1.7% and 1.8%. As expected, DCS systems had improved standard deviation: 0.003–0.05%. The energy was also very stable for all units. The standard deviation in exit detector flatness was 0.02–0.3%. Ion chamber output and 20/10 cm ratios supported these results. The stability for the research system, as monitored with a variety of metrics, is on par with the existing systems. Conclusion: The output and energy of six TomoTherapy units over a total of almost 10 years is quite stable. For each system, the results are consistent between the different measurement tools and techniques, proving not only the dosimetric stability, but that these quality parameters can be confirmed with various metrics. A research unit operating at a higher dose rate performed as well as the clinical treatment units. University of Wisconsin and Accuray Inc. (vendor of TomoTherapy systems) have a research agreement which supplies funds for research to

  16. Recovery of α-Al{sub 2}O{sub 3} from ionizing radiation dosimetric sensors

    Energy Technology Data Exchange (ETDEWEB)

    Sanches, Edgar Aparecido, E-mail: sanches.ufam@gmail.com [Universidade Federal do Amazonas (UFAM), Manaus, AM (Brazil). Dept. de Fisica; Costalonga, Ademir Geraldo Cavallari; Mascarenhas, Yvonne Primerano [Universidade de Sao Paulo (IFSC/USP), Sao Carlos, SP (Brazil). Institute de Fisica; Nascimento, Luana de Freitas [Belgium Nuclear Research Centre, SCK-CEN, Mol (Belgium); Mascarenhas, Yvone Maria [SAPRA S/A Servico de Assessoria e Protecao Radiologica, Sao Carlos, SP, (Brazil)

    2015-01-15

    Corundum, sapphire or α-Al{sub 2}O{sub 3} is an important technological material in many optical and electronic applications such as solid-state lasers, optical windows and, more recently, as a radiation detector. Landauer (Glenwood, IL, USA) accumulated large number of archived and stored Luxel™ dosemeters composed of Al{sub 2}O{sub 3}:C, which were subjected to a recovery process. Due to the importance of this advanced crystalline material in OSL dosimetry, a recovery process was developed based on the dosemeters calcination and Al{sub 2}O{sub 3}:C has been reused in manufacturing of new dosemeters. This paper does not aim to optimize the recovery process, but provides an opportunity to study the involved process parameters and to recover this valuable crystalline material from used dosemeters. To the best of our knowledge no other recovery process involving this dosimetric material was described in scientific literature. Fourier Transform Infrared Spectrometry (FTIR), Thermogravimetry/Differential Thermoanalysis (TG/DTA), Differential Scanning Calorimetry (DSC), X-ray Diffraction (XRD), Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES), Optically Stimulated Luminescence (OSL) and Rietveld Refinement were used to characterize the recovered material and to check for the stability of its structural and dosimetric properties. (author)

  17. Compartmental and dosimetric studies of anti-CD20 labeled with 188Re

    International Nuclear Information System (INIS)

    Barrio Kuramoto Graciela; Mie Nakamura Matsuda Margareth; Osso Joao Jr, Alberto

    2016-01-01

    Radioimmunotherapy has the potential to deliver lethal radiation energy directly to malignant cells via targeting of radioisotope-conjugated monoclonal antibodies (MAbs) to specific antigens. Rituximab (RTX) is specifically targeted against CD20, a surface antigen expressed by B-lymphocytes. The use of 188 Re from a 188 W/ 188 Re generator system represents an alternative radionuclide for therapy. Rhenium has chemical properties similar to technetium and both can be conjugated to antibodies using similar chemistry methods. The objective of this work is to prove the usefulness of this radiopharmaceutical based on dosimetric and pharmacokinetic studies that are also required by the Brazilian Regulatory Agency. (author)

  18. Application of OMEGA Monte Carlo codes for radiation therapy treatment planning

    International Nuclear Information System (INIS)

    Ayyangar, Komanduri M.; Jiang, Steve B.

    1998-01-01

    The accuracy of conventional dose algorithms for radiosurgery treatment planning is limited, due to the inadequate consideration of the lateral radiation transport and the difficulty of acquiring accurate dosimetric data for very small beams. In the present paper, some initial work on the application of Monte Carlo method in radiation treatment planning in general, and in radiosurgery treatment planning in particular, has been presented. Two OMEGA Monte Carlo codes, BEAM and DOSXYZ, are used. The BEAM code is used to simulate the transport of particles in the linac treatment head and radiosurgery collimator. A phase space file is obtained from the BEAM simulation for each collimator size. The DOSXYZ code is used to calculate the dose distribution in the patient's body reconstructed from CT slices using the phase space file as input. The accuracy of OMEGA Monte Carlo simulation for radiosurgery dose calculation is verified by comparing the calculated and measured basic dosimetric data for several radiosurgery beams and a 4 x 4 cm 2 conventional beam. The dose distributions for three clinical cases are calculated using OMEGA codes as the dose engine for an in-house developed radiosurgery treatment planning system. The verification using basic dosimetric data and the dose calculation for clinical cases demonstrate the feasibility of applying OMEGA Monte Carlo code system to radiosurgery treatment planning. (author)

  19. SSDL Argentina: Dosimetric intercomparison programme for cobalt 60 therapy units

    Energy Technology Data Exchange (ETDEWEB)

    Saravi, M; Papadopulos, S; Mugliaroli, H [Comision Nacional de Energia Atomica, Buenos Aires (Argentina)

    1996-08-01

    Thermoluminescence dosimeters (TLD) are widely used to verify absorbed dose delivered from radiation therapy beams. The Secondary Standard Dosimetry Laboratory (SSDL) of Argentina uses TLD for its mailed dose intercomparison programme for cobalt 60 radiation therapy units. Results obtained since 1978 as well as causes of dose discrepancies greater than 5% are analyzed. Results of the external quality control performed by the IAEA for this programme indicate that the dose evaluated by the SSDL TLD service for the participating centers is about 1% lower than that evaluated by the IAEA TLD service. This deviation is accepted taking on account that a {+-} 2% dose uncertainty for TLD dosimetry is reasonable. (author). 5 refs, 5 figs, 2 tabs.

  20. 4π Noncoplanar Stereotactic Body Radiation Therapy for Centrally Located or Larger Lung Tumors

    International Nuclear Information System (INIS)

    Dong, Peng; Lee, Percy; Ruan, Dan; Long, Troy; Romeijn, Edwin; Low, Daniel A.; Kupelian, Patrick; Abraham, John; Yang, Yingli; Sheng, Ke

    2013-01-01

    Purpose: To investigate the dosimetric improvements in stereotactic body radiation therapy for patients with larger or central lung tumors using a highly noncoplanar 4π planning system. Methods and Materials: This study involved 12 patients with centrally located or larger lung tumors previously treated with 7- to 9-field static beam intensity modulated radiation therapy to 50 Gy. They were replanned using volumetric modulated arc therapy and 4π plans, in which a column generation method was used to optimize the beam orientation and the fluence map. Maximum doses to the heart, esophagus, trachea/bronchus, and spinal cord, as well as the 50% isodose volume, the lung volumes receiving 20, 10, and 5 Gy were minimized and compared against the clinical plans. A dose escalation study was performed to determine whether a higher prescription dose to the tumor would be achievable using 4π without violating dose limits set by the clinical plans. The deliverability of 4π plans was preliminarily tested. Results: Using 4π plans, the maximum heart, esophagus, trachea, bronchus and spinal cord doses were reduced by 32%, 72%, 37%, 44%, and 53% (P≤.001), respectively, and R 50 was reduced by more than 50%. Lung V 20 , V 10 , and V 5 were reduced by 64%, 53%, and 32% (P≤.001), respectively. The improved sparing of organs at risk was achieved while also improving planning target volume (PTV) coverage. The minimal PTV doses were increased by the 4π plans by 12% (P=.002). Consequently, escalated PTV doses of 68 to 70 Gy were achieved in all patients. Conclusions: We have shown that there is a large potential for plan quality improvement and dose escalation for patients with larger or centrally located lung tumors using noncoplanar beams with sufficient quality and quantity. Compared against the clinical volumetric modulated arc therapy and static intensity modulated radiation therapy plans, the 4π plans yielded significantly and consistently improved tumor coverage and

  1. 4π Noncoplanar Stereotactic Body Radiation Therapy for Centrally Located or Larger Lung Tumors

    Energy Technology Data Exchange (ETDEWEB)

    Dong, Peng; Lee, Percy; Ruan, Dan [Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California (United States); Long, Troy; Romeijn, Edwin [Department of Industrial and Operations Engineering, University of Michigan, Ann Arbor, Michigan (United States); Low, Daniel A.; Kupelian, Patrick; Abraham, John; Yang, Yingli [Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California (United States); Sheng, Ke, E-mail: ksheng@mednet.ucla.edu [Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California (United States)

    2013-07-01

    Purpose: To investigate the dosimetric improvements in stereotactic body radiation therapy for patients with larger or central lung tumors using a highly noncoplanar 4π planning system. Methods and Materials: This study involved 12 patients with centrally located or larger lung tumors previously treated with 7- to 9-field static beam intensity modulated radiation therapy to 50 Gy. They were replanned using volumetric modulated arc therapy and 4π plans, in which a column generation method was used to optimize the beam orientation and the fluence map. Maximum doses to the heart, esophagus, trachea/bronchus, and spinal cord, as well as the 50% isodose volume, the lung volumes receiving 20, 10, and 5 Gy were minimized and compared against the clinical plans. A dose escalation study was performed to determine whether a higher prescription dose to the tumor would be achievable using 4π without violating dose limits set by the clinical plans. The deliverability of 4π plans was preliminarily tested. Results: Using 4π plans, the maximum heart, esophagus, trachea, bronchus and spinal cord doses were reduced by 32%, 72%, 37%, 44%, and 53% (P≤.001), respectively, and R{sub 50} was reduced by more than 50%. Lung V{sub 20}, V{sub 10}, and V{sub 5} were reduced by 64%, 53%, and 32% (P≤.001), respectively. The improved sparing of organs at risk was achieved while also improving planning target volume (PTV) coverage. The minimal PTV doses were increased by the 4π plans by 12% (P=.002). Consequently, escalated PTV doses of 68 to 70 Gy were achieved in all patients. Conclusions: We have shown that there is a large potential for plan quality improvement and dose escalation for patients with larger or centrally located lung tumors using noncoplanar beams with sufficient quality and quantity. Compared against the clinical volumetric modulated arc therapy and static intensity modulated radiation therapy plans, the 4π plans yielded significantly and consistently improved tumor

  2. Dosimetric characterization of radionuclides for systemic tumor therapy: Influence of particle range, photon emission, and subcellular distribution

    International Nuclear Information System (INIS)

    Uusijaervi, Helena; Bernhardt, Peter; Ericsson, Thomas; Forssell-Aronsson, Eva

    2006-01-01

    Various radionuclides have been proposed for systemic tumor therapy. However, in most dosimetric analysis of proposed radionuclides the charged particles are taken into consideration while the potential photons are ignored. The photons will cause undesirable irradiation of normal tissue, and increase the probability of toxicity in, e.g., the bone marrow. The aim of this study was to investigate the dosimetric properties according to particle range, photon emission, and subcellular radionuclide distribution, of a selection of radionuclides used or proposed for radionuclide therapy, and to investigate the possibility of dividing radionuclides into groups according to their dosimetric properties. The absorbed dose rate to the tumors divided by the absorbed dose rate to the normal tissue (TND) was estimated for different tumor sizes in a mathematical model of the human body. The body was simulated as a 70-kg ellipsoid and the tumors as spheres of different sizes (1 ng-100 g). The radionuclides were either assumed to be uniformly distributed throughout the entire tumor and normal tissue, or located in the nucleus or the cytoplasm of the tumor cells and on the cell membrane of the normal cells. Fifty-nine radionuclides were studied together with monoenergetic electrons, positrons, and alpha particles. The tumor and normal tissue were assumed to be of water density. The activity concentration ratio between the tumor and normal tissue was assumed to be 25. The radionuclides emitting low-energy electrons combined with a low photon contribution, and the alpha emitters showed high TND values for most tumor sizes. Electrons with higher energy gave reduced TND values for small tumors, while a higher photon contribution reduced the TND values for large tumors. Radionuclides with high photon contributions showed low TND value for all tumor sizes studied. The radionuclides studied could be divided into four main groups according to their TND values: beta emitters, Auger electron

  3. SU-F-T-513: Dosimetric Validation of Spatially Fractionated Radiotherapy Using Gel Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Papanikolaou, P; Watts, L; Kirby, N; Rasmussen, K; Gutierrez, A; Stathakis, S [University of Texas HSC SA, San Antonio, TX (United States); Pappas, E [National and Kapodistrian University of Athens, Athens, Attiki (Greece); Kalaitzakis, G; Maris, T [University Of Crete, Heraklion, Crete (Greece); Pappas, E [Technological Educational Institute Of Athens, Athens, Attiki (Greece)

    2016-06-15

    Purpose: Spatially fractionated radiation therapy, also known as GRID therapy, is used to treat large solid tumors by irradiating the target to a single dose of 10–20Gy through spatially distributed beamlets. We have investigated the use of a 3D gel for dosimetric characterization of GRID therapy. Methods: GRID therapy is an external beam analog of volumetric brachytherapy, whereby we produce a distribution of hot and cold dose columns inside the tumor volume. Such distribution can be produced with a block or by using a checker-like pattern with MLC. We have studied both types of GRID delivery. A cube shaped acrylic phantom was filled with polymer gel and served as a 3D dosimeter. The phantom was scanned and the CT images were used to produce two plans in Pinnacle, one with the grid block and one with the MLC defined grid. A 6MV beam was used for the plan with a prescription of 1500cGy at dmax. The irradiated phantom was scanned in a 3T MRI scanner. Results: 3D dose maps were derived from the MR scans of the gel dosimeter and were found to be in good agreement with the predicted dose distribution from the RTP system. Gamma analysis showed a passing rate of 93% for 5% dose and 2mm DTA scoring criteria. Both relative and absolute dose profiles are in good agreement, except in the peripheral beamlets where the gel measured slightly higher dose, possibly because of the changing head scatter conditions that the RTP is not fully accounting for. Our results have also been benchmarked against ionization chamber measurements. Conclusion: We have investigated the use of a polymer gel for the 3D dosimetric characterization and evaluation of GRID therapy. Our results demonstrated that the planning system can predict fairly accurately the dose distribution for GRID type therapy.

  4. SU-F-T-513: Dosimetric Validation of Spatially Fractionated Radiotherapy Using Gel Dosimetry

    International Nuclear Information System (INIS)

    Papanikolaou, P; Watts, L; Kirby, N; Rasmussen, K; Gutierrez, A; Stathakis, S; Pappas, E; Kalaitzakis, G; Maris, T; Pappas, E

    2016-01-01

    Purpose: Spatially fractionated radiation therapy, also known as GRID therapy, is used to treat large solid tumors by irradiating the target to a single dose of 10–20Gy through spatially distributed beamlets. We have investigated the use of a 3D gel for dosimetric characterization of GRID therapy. Methods: GRID therapy is an external beam analog of volumetric brachytherapy, whereby we produce a distribution of hot and cold dose columns inside the tumor volume. Such distribution can be produced with a block or by using a checker-like pattern with MLC. We have studied both types of GRID delivery. A cube shaped acrylic phantom was filled with polymer gel and served as a 3D dosimeter. The phantom was scanned and the CT images were used to produce two plans in Pinnacle, one with the grid block and one with the MLC defined grid. A 6MV beam was used for the plan with a prescription of 1500cGy at dmax. The irradiated phantom was scanned in a 3T MRI scanner. Results: 3D dose maps were derived from the MR scans of the gel dosimeter and were found to be in good agreement with the predicted dose distribution from the RTP system. Gamma analysis showed a passing rate of 93% for 5% dose and 2mm DTA scoring criteria. Both relative and absolute dose profiles are in good agreement, except in the peripheral beamlets where the gel measured slightly higher dose, possibly because of the changing head scatter conditions that the RTP is not fully accounting for. Our results have also been benchmarked against ionization chamber measurements. Conclusion: We have investigated the use of a polymer gel for the 3D dosimetric characterization and evaluation of GRID therapy. Our results demonstrated that the planning system can predict fairly accurately the dose distribution for GRID type therapy.

  5. Radiation Therapy - Multiple Languages

    Science.gov (United States)

    ... W XYZ List of All Topics All Radiation Therapy - Multiple Languages To use the sharing features on this page, ... Information Translations Vietnamese (Tiếng Việt) Expand Section Radiation Therapy - Tiếng Việt (Vietnamese) ... Health Information Translations Characters not displaying correctly on this page? See language display issues . Return to the MedlinePlus Health Information ...

  6. Beam’s-eye-view dosimetrics (BEVD) guided rotational station parameter optimized radiation therapy (SPORT) planning based on reweighted total-variation minimization

    Science.gov (United States)

    Kim, Hojin; Li, Ruijiang; Lee, Rena; Xing, Lei

    2015-03-01

    Conventional VMAT optimizes aperture shapes and weights at uniformly sampled stations, which is a generalization of the concept of a control point. Recently, rotational station parameter optimized radiation therapy (SPORT) has been proposed to improve the plan quality by inserting beams to the regions that demand additional intensity modulations, thus formulating non-uniform beam sampling. This work presents a new rotational SPORT planning strategy based on reweighted total-variation (TV) minimization (min.), using beam’s-eye-view dosimetrics (BEVD) guided beam selection. The convex programming based reweighted TV min. assures the simplified fluence-map, which facilitates single-aperture selection at each station for single-arc delivery. For the rotational arc treatment planning and non-uniform beam angle setting, the mathematical model needs to be modified by additional penalty term describing the fluence-map similarity and by determination of appropriate angular weighting factors. The proposed algorithm with additional penalty term is capable of achieving more efficient and deliverable plans adaptive to the conventional VMAT and SPORT planning schemes by reducing the dose delivery time about 5 to 10 s in three clinical cases (one prostate and two head-and-neck (HN) cases with a single and multiple targets). The BEVD guided beam selection provides effective and yet easy calculating methodology to select angles for denser, non-uniform angular sampling in SPORT planning. Our BEVD guided SPORT treatment schemes improve the dose sparing to femoral heads in the prostate and brainstem, parotid glands and oral cavity in the two HN cases, where the mean dose reduction of those organs ranges from 0.5 to 2.5 Gy. Also, it increases the conformation number assessing the dose conformity to the target from 0.84, 0.75 and 0.74 to 0.86, 0.79 and 0.80 in the prostate and two HN cases, while preserving the delivery efficiency, relative to conventional single-arc VMAT plans.

  7. Beam’s-eye-view dosimetrics (BEVD) guided rotational station parameter optimized radiation therapy (SPORT) planning based on reweighted total-variation minimization

    International Nuclear Information System (INIS)

    Kim, Hojin; Li, Ruijiang; Xing, Lei; Lee, Rena

    2015-01-01

    Conventional VMAT optimizes aperture shapes and weights at uniformly sampled stations, which is a generalization of the concept of a control point. Recently, rotational station parameter optimized radiation therapy (SPORT) has been proposed to improve the plan quality by inserting beams to the regions that demand additional intensity modulations, thus formulating non-uniform beam sampling. This work presents a new rotational SPORT planning strategy based on reweighted total-variation (TV) minimization (min.), using beam’s-eye-view dosimetrics (BEVD) guided beam selection. The convex programming based reweighted TV min. assures the simplified fluence-map, which facilitates single-aperture selection at each station for single-arc delivery. For the rotational arc treatment planning and non-uniform beam angle setting, the mathematical model needs to be modified by additional penalty term describing the fluence-map similarity and by determination of appropriate angular weighting factors. The proposed algorithm with additional penalty term is capable of achieving more efficient and deliverable plans adaptive to the conventional VMAT and SPORT planning schemes by reducing the dose delivery time about 5 to 10 s in three clinical cases (one prostate and two head-and-neck (HN) cases with a single and multiple targets). The BEVD guided beam selection provides effective and yet easy calculating methodology to select angles for denser, non-uniform angular sampling in SPORT planning. Our BEVD guided SPORT treatment schemes improve the dose sparing to femoral heads in the prostate and brainstem, parotid glands and oral cavity in the two HN cases, where the mean dose reduction of those organs ranges from 0.5 to 2.5 Gy. Also, it increases the conformation number assessing the dose conformity to the target from 0.84, 0.75 and 0.74 to 0.86, 0.79 and 0.80 in the prostate and two HN cases, while preserving the delivery efficiency, relative to conventional single-arc VMAT plans

  8. Different Approaches in Radiation Therapy

    Directory of Open Access Journals (Sweden)

    Rolf-Dieter eKortmann

    2011-12-01

    Full Text Available Radiation therapy is a cornerstone in the therapeutic management of craniopharyngioma. The close proximity to neighbouring eloquent structures pose a particular challenge to radiation therapy. Modern treatment technologies including fractionated 3-d conformal radiotherapy, intensity modulated radiation therapy and recently proton therapy are able to precisely cover the target while preserving surrounding tissue,Tumour controls between 80 and in access of 90 % can be achieved. Alternative treatments consisting of radiosurgery, intracavitary application of isotopes and brachytherapy also offer an acceptable tumour control and might be given in selected cases. More research is needed to establish the role of each treatment modality.

  9. Analysis of influence of dosimetric factors on the outcome of I-131 therapy in patients with hyperthyroidism

    International Nuclear Information System (INIS)

    Knapska-Kucharska, M.; Oszukowska, L.; Makarewicz, J.; Lewinski, A.

    2012-01-01

    The influence of dosimetric factors on the outcome of 131 I therapy has been examined in hyperthyroid patients submitted to 131 I treatment. The following factors - which could have influence on the effects of therapy with radioiodine - were analysed: the goitre volume, the thyroid radioiodine uptake after 24 h, and the effective half-life time of 131 I (EHL). Five hundred (500) randomly selected patients with hyperthyroidism, treated with 131 I, were studied. They were divided into three groups (based on clinical examination, hormonal and immunological tests, thyroid scintigraphy and ultrasound imaging). The study shows that the effectiveness of 131 I therapy depends on the thyroid volume and absorbed dose in all the groups of patients and on the thyroid radioiodine uptake and EHL in patients with a single autonomously functioning thyroid nodule. We have failed to determine the borderline D, distinguishing between effective and ineffective therapy. The treatment outcome can be predicted with approximately 70% accuracy, based on minimal absorbed dose

  10. Analysis of influence of dosimetric factors on the outcome of I-131 therapy in patients with hyperthyroidism

    Energy Technology Data Exchange (ETDEWEB)

    Knapska-Kucharska, M.; Oszukowska, L.; Makarewicz, J. [Department of Nuclear Medecine and Oncological Endocrinology, Province Hospital, Zgierz (Poland); Lewinski, A. [Chair and Department of Endocrinology and Metabolic Diseases, Medical University, Lodz (Poland)

    2012-07-01

    The influence of dosimetric factors on the outcome of {sup 131}I therapy has been examined in hyperthyroid patients submitted to {sup 131}I treatment. The following factors - which could have influence on the effects of therapy with radioiodine - were analysed: the goitre volume, the thyroid radioiodine uptake after 24 h, and the effective half-life time of {sup 131}I (EHL). Five hundred (500) randomly selected patients with hyperthyroidism, treated with {sup 131}I, were studied. They were divided into three groups (based on clinical examination, hormonal and immunological tests, thyroid scintigraphy and ultrasound imaging). The study shows that the effectiveness of {sup 131}I therapy depends on the thyroid volume and absorbed dose in all the groups of patients and on the thyroid radioiodine uptake and EHL in patients with a single autonomously functioning thyroid nodule. We have failed to determine the borderline D, distinguishing between effective and ineffective therapy. The treatment outcome can be predicted with approximately 70% accuracy, based on minimal absorbed dose

  11. Use of a dosimetric system using a SMT phototransistor in the measurement for some dosimetric parameters in conventional radiotherapy

    International Nuclear Information System (INIS)

    Silva, J.O. da; Magalhaes, C.M.S. de; Santos, L.A.P.

    2008-01-01

    For monitoring the delivered dose in the patient undergoing a cancer treatment with high-energy ionizing radiation beams is necessary to use appropriate dosimeters for the beam control quality and if it is possible, to obtain the dose information during the treatment. For this, semiconductor-based devices are used because of their high spatial resolution and to be easy to handle in spite of the ionization chambers. Nowadays the bipolar phototransistors are being proposed as ionizing radiation detectors for presenting, beyond these characteristics, the signal amplification factor (gain). So, the aim of this work is to present the use of a dosimetric system using a SMT phototransistor in the measurement for some dosimetric parameters in conventional radiotherapy: the field factor and the off-axis ratio. The phototransistors readings were compared with ones obtained from a PTW 23343 Markus chamber, under the same conditions. (author)

  12. Modern Radiation Therapy for Hodgkin Lymphoma

    DEFF Research Database (Denmark)

    Specht, Lena; Yahalom, Joachim; Illidge, Tim

    2014-01-01

    Radiation therapy (RT) is the most effective single modality for local control of Hodgkin lymphoma (HL) and an important component of therapy for many patients. These guidelines have been developed to address the use of RT in HL in the modern era of combined modality treatment. The role of reduced...... on Radiation Units and Measurements concepts of gross tumor volume, clinical target volume, internal target volume, and planning target volume are used for defining the targeted volumes. Newer treatment techniques, including intensity modulated radiation therapy, breath-hold, image guided radiation therapy......, and 4-dimensional imaging, should be implemented when their use is expected to decrease significantly the risk for normal tissue damage while still achieving the primary goal of local tumor control. The highly conformal involved node radiation therapy (INRT), recently introduced for patients for whom...

  13. Dosimetric comparison of treatment techniques IMRT and VMAT for breast cancer

    International Nuclear Information System (INIS)

    Urbina, G. L.; Garcia, B. G.

    2015-10-01

    In this study the dosimetric distribution was compared in the different treatment techniques such as Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiation Therapy (IMRT) in female patients with breast cancer with stage II-B and III-A, 6 cases (both calculated on VMAT and IMRT) were studied, comparison parameter that are taken into account are: compliance rate, homogeneity index, monitor units, volume dose 50 Gy (D-50%) and 5 Gy (D-5%) volume dose. Comparisons are made in primary tumor volume to optimize treatment in patients with breast cancer, with IMRT using Step, Shoot and VMAT Monte Carlo algorithm, in addition to the organs at risk; the concern to make this work is due to technological advances in radiotherapy and the application of new treatment techniques, that increase the accuracy allowing treatment dose climbing delivering a higher dose to the patient. (Author)

  14. Computer-assisted selection of coplanar beam orientations in intensity-modulated radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Pugachev, A.; Xing, L. [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA (United States)]. E-mail: lei@reyes.stanford.edu

    2001-09-01

    In intensity-modulated radiation therapy (IMRT), the incident beam orientations are often determined by a trial and error search. The conventional beam's-eye view (BEV) tool becomes less helpful in IMRT because it is frequently required that beams go through organs at risk (OARs) in order to achieve a compromise between the dosimetric objectives of the planning target volume (PTV) and the OARs. In this paper, we report a beam's-eye view dosimetrics (BEVD) technique to assist in the selection of beam orientations in IMRT. In our method, each beam portal is divided into a grid of beamlets. A score function is introduced to measure the 'goodness' of each beamlet at a given gantry angle. The score is determined by the maximum PTV dose deliverable by the beamlet without exceeding the tolerance doses of the OARs and normal tissue located in the path of the beamlet. The overall score of the gantry angle is given by a sum of the scores of all beamlets. For a given patient, the score function is evaluated for each possible beam orientation. The directions with the highest scores are then selected as the candidates for beam placement. This procedure is similar to the BEV approach used in conventional radiation therapy, except that the evaluation by a human is replaced by a score function to take into account the intensity modulation. This technique allows one to select beam orientations without the excessive computing overhead of computer optimization of beam orientation. It also provides useful insight into the problem of selection of beam orientation and is especially valuable for complicated cases where the PTV is surrounded by several sensitive structures and where it is difficult to select a set of 'good' beam orientations. Several two-dimensional (2D) model cases were used to test the proposed technique. The plans obtained using the BEVD-selected beam orientations were compared with the plans obtained using equiangular spaced beams. For

  15. Radiation therapy for gastric cancer

    International Nuclear Information System (INIS)

    Dobelbower, R.R.; Bagne, F.; Ajlouni, M.I.; Milligan, A.J.

    1988-01-01

    Adenocarcinoma of the stomach is a moderately radioresponsive neoplasm. Attempts to treat patients with unresectable disease with external beam radiation therapy alone have generally failed because of problems with tumor localization and adequate dose delivery as well as the inherent radioresponsiveness of the gastric mucosa and the organs intimately related to the stomach. Combining external beam therapy and chemotherapy (acting as a systemic agent and as a radiosensitizer) seems to be of some (albeit limited) benefit in the management of unresectable adenocarcinoma of the stomach. Optimum combinations of radiation therapy, chemotherapy, and radiation sensitizers in this situation remain to be determined. The authors discuss strides which have been made in the treatment of gastric cancer. They also address the unanswered clinical questions which remain regarding the use of radiation therapy in the treatment of this highly lethal disease

  16. Reduced Toxicity With Intensity Modulated Radiation Therapy (IMRT) for Desmoplastic Small Round Cell Tumor (DSRCT): An Update on the Whole Abdominopelvic Radiation Therapy (WAP-RT) Experience

    Energy Technology Data Exchange (ETDEWEB)

    Desai, Neil B. [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Stein, Nicholas F. [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); LaQuaglia, Michael P. [Department of Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Alektiar, Kaled M. [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Kushner, Brian H.; Modak, Shakeel; Magnan, Heather M. [Department of Pediatrics, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Goodman, Karyn [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Wolden, Suzanne L., E-mail: woldens@mskcc.org [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States)

    2013-01-01

    Purpose: Desmoplastic small round cell tumor (DSRCT) is a rare malignancy typically involving the peritoneum in young men. Whole abdominopelvic radiation therapy (WAP-RT) using conventional 2-dimensional (2D) radiation therapy (RT) is used to address local recurrence but has been limited by toxicity. Our objectives were to assess the benefit of intensity modulated radiation therapy (IMRT) on toxicity and to update the largest series on radiation for DSRCT. Methods and Materials: The records of 31 patients with DSRCT treated with WAP-RT (22 with 2D-RT and 9 with IMRT) between 1992 and 2011 were retrospectively reviewed. All received multi-agent chemotherapy and maximal surgical debulking followed by 30 Gy of WAP-RT. A further focal boost of 12 to 24 Gy was used in 12 cases. Boost RT and autologous stem cell transplantation were nearly exclusive to patients treated with 2D-RT. Toxicities were assessed with the Common Terminology Criteria for Adverse Events. Dosimetric analysis compared IMRT and simulated 2D-RT dose distributions. Results: Of 31 patients, 30 completed WAP-RT, with a median follow-up after RT of 19 months. Acute toxicity was reduced with IMRT versus 2D-RT: P=.04 for gastrointestinal toxicity of grade 2 or higher (33% vs 77%); P=.02 for grade 4 hematologic toxicity (33% vs 86%); P=.01 for rates of granulocyte colony-stimulating factor; and P=.04 for rates of platelet transfusion. Post treatment red blood cell and platelet transfusion rates were also reduced (P=.01). IMRT improved target homogeneity ([D05-D95]/D05 of 21% vs 46%) and resulted in a 21% mean bone dose reduction. Small bowel obstruction was the most common late toxicity (23% overall). Updated 3-year overall survival and progression-free survival rates were 50% and 24%, respectively. Overall survival was associated with distant metastasis at diagnosis on multivariate analysis. Most failures remained intraperitoneal (88%). Conclusions: IMRT for consolidative WAP-RT in DSRCT improves

  17. Why do patients drop out during radiation therapy?

    International Nuclear Information System (INIS)

    Huh, Seung Jae; Ahn, Yong Chan; Kim, Dae Yong; Shin, Kyung Hwan; Lee, Kyu Chan; Chong, Won A; Kim, Hyun Joo; Wu, Hong Gyun

    1998-01-01

    This study is to see how much proportion of the patients receiving radiation therapy drop out during radiation therapy and to analyze the reason for the incomplete treatment. The base population of this study was 1,100 patients with registration numbers 901 through 2,000 at Department of Radiation Oncology, Samsung Medical Center, Seoul, Korea. Authors investigated the incidence of incomplete radiation therapy, which was defined as less than 95% of initially planned radiation dose, and the reasons for incomplete radiation therapy. One hundred and twenty eight patients (12%) did not complete the planned radiation therapy. The performance status of the incompletely treated patients was generally poorer than that of the base population, and the aim of radiation therapy was more commonly palliative. The most common reason for not completing the planned treatment was the patients' refusal of further radiation therapy because of the distrust of radiation therapy and/or the poor economic status. Careful case selection for radiation therapy with consideration of the socioeconomic status of the patients in addition to the clinical indication would be necessary for the reduction of incomplete treatment, especially in the palliative setting

  18. In-vivo dosimetric study of carcinoma of uterine cervix with FBX solution in external beam therapy

    International Nuclear Information System (INIS)

    Srinivas, Challapalli; Shenoy, K. Kamalaksh; Dinesh, M.; Savitha, K.S.; Kasturi, Dinesh Pai; Supe, S.S.; Nagesha, Y.N.

    1999-01-01

    To ensure accurate dose delivery to target site in external beam therapy and brachytherapy, various authors have conducted tests to assess the process of manual dose calculations. In vivo dosimetric measurement is one of these methods to verify these calculations. In this study, an attempt has been made to compare the manually calculated dose to dose estimated using a chemical dosimeter (FBX) solution (in-vivo method, using polypropylene vials), on 12 patients of carcinoma of uterine cervix in external beam therapy. Dose measured by FBX vial varies in the range of ± 2 to 6.75%, as compared with manual calculations. These variations seen may be attributed to the location of the vial position in the vagina, with reference to the beam axis (may not be horizontal), off axis position, manual calculation variations and reproducibility of the FBX system etc. FBX dosimetry offers itself as an in-vivo method to estimate the dose delivered to the target site in external beam therapy. (author)

  19. 42 CFR 410.35 - X-ray therapy and other radiation therapy services: Scope.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false X-ray therapy and other radiation therapy services... Other Health Services § 410.35 X-ray therapy and other radiation therapy services: Scope. Medicare Part B pays for X-ray therapy and other radiation therapy services, including radium therapy and...

  20. Dosimetric comparison between RapidArc and fixed gantry intensity modulated radiation therapy in treatment of liver carcinoma

    International Nuclear Information System (INIS)

    Ma Changsheng; Yin Yong; Liu Tonghai; Chen Jinhu; Sun Tao; Lin Xiutong

    2010-01-01

    Objective: To compare the dosimetric difference of RapidArc and fixed gantry IMRT for liver carcinoma. Methods: The CT data of 10 liver cancer patients were used to design 3 groups of treatment plan: IMRT plan, single arc RapidArc plan (RA1), and dual arc RapidArc plan (RA2). The planning target volume (PTV) dosimetric distribution, the organs at risk (OAR) dose, the normal tissue dose, mornitor units (MU) and treatment time were compared. Results: The maximum dose of PTV in RA1 and RA2 plans were lower than that of IMRT (Z=-2.0990, -2.666, P 40 of stomach small bowel than IMRT plan, but higher in mean dose of left kidney (Z=-1.988, -2.191, P 5 , V 10 and 15 of healthy tissue in RapidArc plan groups were higher than those in IMRT plan, while the values of V 20 , V 25 and V 30 of healthy tissue in RapidArc plan groups were than those in IMRT plan. The number of computed MU/fraction of Rapid Arc plan was 40% or 46% of IMRT plan and the treatment time was 30% and 40% of IMRT. Conclusions: RapidArc showed improvements in conformity index and healthy tissue sparing with uncompromised target coverage. RapidArc could lead to the less MU and shorter delivery time compared to IMRT. (authors)

  1. Micro-Mini & Nano-Dosimetry & Innovative Technologies in Radiation Therapy (MMND&ITRO2016)

    Science.gov (United States)

    2017-01-01

    The biennial MMND (formerly MMD) - IPCT workshops, founded in collaboration with Memorial Sloan Kettering Cancer Center (MSKCC) in 2001, has become an important international multidisciplinary forum for the discussion of advanced dosimetric technology for radiation therapy quality assurance (QA) and space science, as well as advanced technologies for prostate cancer treatment. In more recent years, the interests of participants and the scope of the workshops have extended far beyond prostate cancer treatment alone to include all aspects of radiation therapy, radiation science and technology. We therefore decided to change the name in 2016 to Innovative Technologies in Radiation Oncology (ITRO). MMND ITRO 2016 was held on 26-31 January, 2016 at the beautiful Wrest Point Hotel in Hobart, Tasmania and attracted an outstanding international faculty and nearly 200 delegates from 18 countries (http://mmnditro2016.com/) The MMND 2016 program continued to cover advanced medical physics aspects of IMRT, IGRT, VMAT, SBRT, MRI LINAC, innovative brachytherapy, and synchrotron MRT. The demand for sophisticated real time and high temporal and spatial resolution (down to the submillimetre scale) dosimetry methods and instrumentation for end-to-end QA for these radiotherapy technologies is increasing. Special attention was paid to the contribution of advanced imaging and the application of nanoscience to the recent improvements in imaging and radiotherapy. The last decade has seen great progress in charged particle therapy technology which has spread throughout the world and attracted strong current interest in Australia. This demands a better understanding of the fundamental aspects of ion interactions with biological tissue and the relative biological effectiveness (RBE) of protons and heavy ions. The further development of computational and experimental micro-and nano-dosimetry for ions has important application in radiobiology based treatment planning and space radiation

  2. Radiation Therapy for Cancer

    Science.gov (United States)

    Radiation therapy is a type of cancer treatment that uses high doses of radiation to kill cancer cells and shrink tumors. Learn about the types of radiation, why side effects happen, which ones you might have, and more.

  3. Radiation therapy of thoracic and abdominal tumors

    International Nuclear Information System (INIS)

    LaRue, S.M.; Gillette, S.M.; Poulson, J.M.

    1995-01-01

    Until recently, radiotherapy of thoracic and abdominal tumors in animals has been limited. However, the availability of computerized tomography and other imaging techniques to aid in determining the extent of tumor, an increase in knowledge of dose tolerance of regional organs, the availability of isocentrically mounted megavoltage machines, and the willingness of patients to pursue more aggressive treatment is making radiation therapy of tumors in these regions far more common. Tumor remission has been reported after radiation therapy of thymomas. Radiation therapy has been used to treat mediastinal lymphoma refractory to chemotherapy, and may be beneficial as part of the initial treatment regimen for this disease. Chemodectomas are responsive to radiation therapy in human patients, and favorable response has also been reported in dogs. Although primary lung tumors in dogs are rare, in some cases radiation therapy could be a useful primary or adjunctive therapy. Lung is the dose-limiting organ in the thorax. Bladder and urethral tumors in dogs have been treated using intraoperative and external-beam radiation therapy combined with chemotherapy. These tumors are difficult to control locally with surgery alone, although the optimal method of combining treatment modalities has not been established. Local control of malignant perianal tumors is also difficult to achieve with surgery alone, and radiation therapy should be used. Intraoperative radiation therapy combined with external-beam radiation therapy has been used for the management of metastatic carcinoma to the sublumbar lymph nodes. Tolerance of retroperitoneal tissues may be decreased by disease or surgical manipulation

  4. Definition of treatment geometry in radiation therapy

    International Nuclear Information System (INIS)

    Aaltonen, P.

    1996-01-01

    When accurate systems for quality assurance and treatment optimization are employed, a precise system for fixation and dosimetric and portal verification are as important as a continued and standardized code of practice for dosimetry and patient follow-up, including registration of tumour responses and acute and late normal tissue reactions. To improve the accuracy of existing dose response relations in order to improve future therapy the treatment geometry and dose delivery concepts have to be accurately defined and uniformly employed. A Nordic working group was set up in 1991 (by Nordic Association of Clinica Physics) to standardize the concepts and quantities used during the whole radiotherapy process in the Nordic countries. Now the group is finalizing its report ''Specification of Dose Delivery in Radiation Therapy''. The report emphasizes that the treatment geometry shall be consistent with the geometry used during the diagnostic work up. The patient fixation is of importance early in the diagnostic phase to ensure that the same reference points and patients position will be used both during the diagnostic work up, simulation and treatment execution. Reference Coordinate System of the patient is a concept based on defined anatomic reference points. This Patient Reference System is a local system which has validity for the tissues, organs and volumes defined during radiotherapy. The reference points of the Patient Reference System should in turn be used for beam set-up. The treatment geometry is then defined by using different concepts describing tissues which are mobile in the Patient Reference System, and finally, volumes which are fixed in this coordinate system. A Set-up Margin has to be considered for movements of the volumes defined in the Reference Coordinate System of the Patient in relation to the radiation beam. The Set-up Margin is dependent on the treatment technique and it is needed in the treatment planning procedure to ensure that the prescribed

  5. Definition of treatment geometry in radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Aaltonen, P [Finnish Centre for Radiation and Nuclear Safety (STUK), Helsinki (Finland)

    1996-08-01

    When accurate systems for quality assurance and treatment optimization are employed, a precise system for fixation and dosimetric and portal verification are as important as a continued and standardized code of practice for dosimetry and patient follow-up, including registration of tumour responses and acute and late normal tissue reactions. To improve the accuracy of existing dose response relations in order to improve future therapy the treatment geometry and dose delivery concepts have to be accurately defined and uniformly employed. A Nordic working group was set up in 1991 to standardize the concepts and quantities used during the whole radiotherapy process in the Nordic countries. Now the group is finalizing its report ``Specification of Dose Delivery in Radiation Therapy``. The report emphasizes that the treatment geometry shall be consistent with the geometry used during the diagnostic work up. The patient fixation is of importance early in the diagnostic phase to ensure that the same reference points and patients position will be used both during the diagnostic work up, simulation and treatment execution. Reference Coordinate System of the patient is a concept based on defined anatomic reference points. This Patient Reference System is a local system which has validity for the tissues, organs and volumes defined during radiotherapy. The reference points of the Patient Reference System should in turn be used for beam set-up. The treatment geometry is then defined by using different concepts describing tissues which are mobile in the Patient Reference System, and finally, volumes which are fixed in this coordinate system. A Set-up Margin has to be considered for movements of the volumes defined in the Reference Coordinate System of the Patient in relation to the radiation beam. The Set-up Margin is dependent on the treatment technique and it is needed in the treatment planning procedure to ensure that the prescribed dose to the Target Volume is delivered.

  6. EPR dosimetric properties of 2-methylalanine pellet for radiation processing application

    International Nuclear Information System (INIS)

    Soliman, Y.S.; Ali, Laila I.; Moustafa, H.; Tadros, Soad M.

    2014-01-01

    The dosimetric characteristics of γ-radiation induced free radicals in 2-methylalanine (2MA) pellet dosimeter are investigated using electron paramagnetic resonance (EPR) in the high-dose range of 1–100 kGy. The EPR spectrum of γ-irradiated 2MA exhibits an isotropic EPR signal with seven lines. The dosimeter response is humidity independent in the range of 33–76% relative humidity. The manufactured dosimeter is typically adipose tissue equivalent in the energy level of 0.1–15 MeV. The overall uncertainty (2σ) of the dosimeter is less than 6.9%. - Highlights: • Preparation of 2-methyl alanine pellets for high-dose dosimetry (1–100 kGy). • The dosimeter response is humidity independent in 33–76% relative humidity range during irradiation. • The temperature coefficient equals 0.96%/°C in the range of 21–60 °C. • Overall uncertainty of the dosimeter not exceeds 6.9% at 2σ

  7. Luxol Fast Blue as a dosimetric material for industrial radiation processes

    International Nuclear Information System (INIS)

    Rushdi, M.A.H.; Beshir, W.B; Abdel-Fattah, A.A; Soliman, Y.S

    2015-01-01

    Using of polyvinyl butyral (PVB) film containing loxul fast blue (LFB) dye, thin films were prepared. Upon irradiation these films undergo a gradual change in color. Optical density change was analyzed spectrophotometrically at the maximum of the absorption band peaking at 421 nm. The useful dose range of film dosimeter response was seen from 0.5 to 50 kGy with (r2 = 0.999). Effects of the dosimetric parameters such as relative humidity and post-irradiation storage in dark and indirect daylight conditions on dosimeters performance were discussed. Addition studies have been done to evaluate the film dosimeter behavior at different energy regions including the mass energy absorption coefficient and mass stopping power dependence of the system. The effective atomic number and the radiation chemical yield for the film dosimeter were determined. The uncertainty budget for high doses has obtained from the measurement with value of 4.86% at 2σ confidence level.

  8. Dosimetric considerations and radiation protection of patients in interventional cardiology

    International Nuclear Information System (INIS)

    Ciraj-Bjelac, O.; Arandjic, D.; Kosutic, D.; Loncar, B.

    2009-01-01

    The paper summarizes results of measurements of relevant dosimetric quantities in interventional cardiology. Dosimetric data were collected for 117 coronary angiography (CA) procedures, 69 percutaneous coronary interventions (PCI) and 41 combined procedures (CA+PCI), taking into account two quantities: air kerma area product (KAP) d air kerma in international reference point (K IRP ). Mean KAP values were 78 Gy·cm 2 , 113 Gy·cm 2 and 141 Gy·cm 2 for CA, PCI i CA+PCI, respectively. Corresponding mean K IRP values were 1.2 Gy, 1.8 Gy and 2.2 Gy. With respect to high dose values, risk for stochastic effects and tissue reactions, dose management methods were proposed. (author) [sr

  9. Risk analysis of external radiation therapy

    International Nuclear Information System (INIS)

    Arvidsson, Marcus

    2011-09-01

    External radiation therapy is carried out via a complex treatment process in which many different groups of staff work together. Much of the work is dependent on and in collaboration with advanced technical equipment. The purpose of the research task has been to identify a process for external radiation therapy and to identify, test and analyze a suitable method for performing risk analysis of external radiation therapy

  10. Gene expression profiles in cervical cancer with radiation therapy alone and chemo-radiation therapy

    International Nuclear Information System (INIS)

    Lee, Kyu Chan; Kim, Joo Young; Hwang, You Jin; Kim, Meyoung Kon; Choi, Myung Sun; Kim, Chul Young

    2003-01-01

    To analyze the gene expression profiles of uterine cervical cancer, and its variation after radiation therapy, with or without concurrent chemotherapy, using a cDNA microarray. Sixteen patients, 8 with squamous cell carcinomas of the uterine cervix, who were treated with radiation alone, and the other 8 treated with concurrent chemo-radiation, were included in the study. Before the starting of the treatment, tumor biopsies were carried out, and the second time biopsies were performed after a radiation dose of 16.2-27 Gy. Three normal cervix tissues were used as a control group. The microarray experiments were performed with 5 groups of the total RNAs extracted individually and then admixed as control, pre-radiation therapy alone, during-radiation therapy alone, pre-chemoradiation therapy, and during chemoradiation therapy. The 33P-labeled cDNAs were synthesized from the total RNAs of each group, by reverse transcription, and then they were hybridized to the cDNA microarray membrane. The gene expression of each microarrays was captured by the intensity of each spot produced by the radioactive isotopes. The pixels per spot were counted with an Arrayguage, and were exported to Microsoft Excel. The data were normalized by the Z transformation, and the comparisons were performed on the Z-ratio values calculated. The expressions of 15 genes, including integrin linked kinase (ILK), CDC28 protein kinase 2, Spry 2, and ERK 3, were increased with the Z-ratio values of over 2.0 for the cervix cancer tissues compared to those for the normal controls. Those genes were involved in cell growth and proliferation, cell cycle control, or signal transduction. The expressions of the other 6 genes, including G protein coupled receptor kinase 6, were decreased with the Z-ratio values of below -2.0. After the radiation therapy, most of the genes, with a previously increase expressions, represented the decreased expression profiles, and the genes, with the Z-ratio values of over 2.0, were

  11. Three-dimensional conformal radiation therapy: the tomo-therapy approach

    International Nuclear Information System (INIS)

    Linthout, N.; Verellen, D.; Coninck, P. de; Bel, A.; Storme, G.

    2000-01-01

    Conformal radiation therapy allows the possibility of delivering high doses at the tumor volume whilst limiting the dose to the surrounding tissues and diminishing the secondary effects. With the example of the conformal radiation therapy used at the AZ VU8 (3DCRT and tomo-therapy), two treatment plans of a left ethmoid carcinoma will be evaluated and discussed in detail. The treatment of ethmoid cancer is technically difficult for both radiation therapy and surgery because of the anatomic constraints and patterns of local spread. A radiation therapy is scheduled to be delivered after surgical resection of the tumor. The treatment plan for the radiation therapy was calculated on a three-dimensional (3D) treatment planning system based on virtual simulation with a beam's eye view: George Sherouse's Gratis. An effort was made to make the plan as conformal and as homogeneous as possible to deliver a dose of 66 Gy in 33 fractions at the tumor bed with a maximum dose of 56 Gy to the right optic nerve and the chiasma. To establish the clinical utility and potential advantages of tomo-therapy over 3DCRT for ethmoid carcinoma, the treatment of this patient was also planned with Peacock Plant. For both treatment plans the isodose distributions and cumulative dose volume histograms (CDVH) were computed. Superimposing the CDVHs yielded similar curves for the target and an obvious improvement for organs at risk such as the chiasma, brainstem and the left eye when applying tomo-therapy. These results have also been reflected in the tumor control probabilities (equal for both plans) and the normal tissue complication probabilities (NTCP), yielding significant reductions in NTCP for tomo-therapy. The probability of uncomplicated tumor control was 52.7% for tomo-therapy against 38.3% for 3DCRT. (authors)

  12. Protection of the patient in radiation therapy

    International Nuclear Information System (INIS)

    1991-01-01

    In the ICRP report (ICRP-Pub-44) a broad picture of radiotheraphy is presented useful to all involved in the care of cancer patients, for instance to physicians, including medical oncologists, and to medical physicists, radiographers, dosimetrists, and administrators. Information is given on the general principles of radiation therapy including external beam therapy and brachytherapy; the accuracy of radiation delivery and quality assurance; the biological radiation response; the expected risk to specific organs or tissues from therapeutic irradiation; the absorbed dose to tissues inside and outside the useful radiation beams; the organization and planning of radiation oncology services; radiation therapy staff education, training and duties; and finally medical research involving the use of radiation therapy. (orig./HP) [de

  13. Dosimetric Predictors of Radiation-Induced Vaginal Stenosis After Pelvic Radiation Therapy for Rectal and Anal Cancer

    International Nuclear Information System (INIS)

    Son, Christina H.; Law, Ethel; Oh, Jung Hun; Apte, Aditya P.; Yang, T. Jonathan; Riedel, Elyn; Wu, Abraham J.; Deasy, Joseph O.; Goodman, Karyn A.

    2015-01-01

    Purpose: Although vaginal stenosis (VS) is a recognized toxicity in women who receive pelvic radiation therapy (RT), the relationship between RT dose and the volume and extent of toxicity has not been analyzed. We modeled this relationship to identify predictors of VS. Methods and Materials: We evaluated 54 women, aged 29 to 78 years, who underwent pelvic RT for rectal or anal cancer during 2008 to 2011 and were enrolled in a prospective study evaluating vaginal dilator use. Maximum dilator size was measured before RT (baseline) and 1 month and 12 months after RT. Dilator use was initiated at 1 month. The difference (D) in dilator size before and after RT was recorded. Those with D ≤−1 were classified as having VS (n=35); those with D ≥0 were classified as having no VS (n=19 at 1 month). Dose-volume parameters were extracted, and the generalized equivalent uniform dose (gEUD) was used to build a predictive model. Results: The mean vaginal doses were 50.0 Gy and 36.8 Gy for anal and rectal cancer patients, respectively. One month after RT, a gEUD model using a wide range of a values suggests that sparing of vaginal volume to a low dose may be important. When gEUD (a = −1) was <35 Gy and the mean vaginal dose was <43 Gy, severe VS was reduced (P=.02). A 1-year analysis suggests increasingly negative D values with increasing mean dose. However, patients with compliance <40% were more likely to have toxicity. Conclusions: Vaginal stenosis is influenced by multiple RT dose-volume characteristics. Mean dose and gEUD constraints together may reduce the risk of severe VS. Patients receiving higher mean vaginal doses should have greater compliance with dilator therapy to minimize risk of toxicity. Further validation with independent datasets is needed

  14. Dosimetric Predictors of Radiation-Induced Vaginal Stenosis After Pelvic Radiation Therapy for Rectal and Anal Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Son, Christina H.; Law, Ethel [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Oh, Jung Hun; Apte, Aditya P. [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Yang, T. Jonathan [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Riedel, Elyn [Department of Biostatistics, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Wu, Abraham J. [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Deasy, Joseph O. [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Goodman, Karyn A., E-mail: goodmank@mskcc.org [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States)

    2015-07-01

    Purpose: Although vaginal stenosis (VS) is a recognized toxicity in women who receive pelvic radiation therapy (RT), the relationship between RT dose and the volume and extent of toxicity has not been analyzed. We modeled this relationship to identify predictors of VS. Methods and Materials: We evaluated 54 women, aged 29 to 78 years, who underwent pelvic RT for rectal or anal cancer during 2008 to 2011 and were enrolled in a prospective study evaluating vaginal dilator use. Maximum dilator size was measured before RT (baseline) and 1 month and 12 months after RT. Dilator use was initiated at 1 month. The difference (D) in dilator size before and after RT was recorded. Those with D ≤−1 were classified as having VS (n=35); those with D ≥0 were classified as having no VS (n=19 at 1 month). Dose-volume parameters were extracted, and the generalized equivalent uniform dose (gEUD) was used to build a predictive model. Results: The mean vaginal doses were 50.0 Gy and 36.8 Gy for anal and rectal cancer patients, respectively. One month after RT, a gEUD model using a wide range of a values suggests that sparing of vaginal volume to a low dose may be important. When gEUD (a = −1) was <35 Gy and the mean vaginal dose was <43 Gy, severe VS was reduced (P=.02). A 1-year analysis suggests increasingly negative D values with increasing mean dose. However, patients with compliance <40% were more likely to have toxicity. Conclusions: Vaginal stenosis is influenced by multiple RT dose-volume characteristics. Mean dose and gEUD constraints together may reduce the risk of severe VS. Patients receiving higher mean vaginal doses should have greater compliance with dilator therapy to minimize risk of toxicity. Further validation with independent datasets is needed.

  15. Radiation biology and radiation therapy

    International Nuclear Information System (INIS)

    Wideroee, R.

    1975-01-01

    Radiation biology and radiation therapy can be compared with investigations in different layers of earth. Radiation biology works upwards from the elementary foundations, therapy works downwards with roots to secure and improve the clinical 'surface work'. The Ellis formula (Strandquist), which is a collection of clinical experience, is suited to form connections with radiobiology in the middle layers, and cooperation can give impulses for research. The structure and conditions of tumours and the complicated problems met with are discussed, based on the Carmel symposium of 1969. The oxygen problem in anoxic tumours is not yet solved. Experimental investigations of the effect itself give partly contradictory results. From a clinical viewpoint reoxygenation is of the utmost significance for obtaining control over the primary tumour, and advanced irradiation programmes will here give better results than the traditional ones. New chemicals, e.g. R 0 -07-0582, appear to reduce the OER value to 1.5, thereby making neutron therapy superfluous. Finally a problem from fundamental research is dealt with, wherein two hypotheses explaining the β-effect are described. The repair hypothesis gives a simple explanation but leaves many questions unanswered. The other hypothesis explains the β-effect as two neighbouring single breaks of the DNA molecule. It still presents difficulties, and is scarcely the correct explanation. (JIW)

  16. Impact of intravenous contrast used in computed tomography on radiation dose to carotid arteries and thyroid in intensity-modulated radiation therapy planning for nasopharyngeal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Victor Ho Fun, E-mail: vhflee@hku.hk; Ng, Sherry Chor Yi; Kwong, Dora Lai Wan; Lam, Ka On; Leung, To Wai

    2017-07-01

    The aim of this study was to investigate if intravenous contrast injection affected the radiation doses to carotid arteries and thyroid during intensity-modulated radiation therapy (IMRT) planning for nasopharyngeal carcinoma (NPC). Thirty consecutive patients with NPC underwent plain computed tomography (CT) followed by repeated scanning after contrast injection. Carotid arteries (common, external, internal), thyroid, target volumes, and other organs-at-risk (OARs), as well as IMRT planning, were based on contrast-enhanced CT (CE-CT) images. All these structures and the IMRT plans were then copied and transferred to the non–contrast-enhanced CT (NCE-CT) images, and dose calculation without optimization was performed again. The radiation doses to the carotid arteries and the thyroid based on CE-CT and NCE-CT were then compared. Based on CE-CT, no statistical differences, despite minute numeric decreases, were noted in all dosimetric parameters (minimum, maximum, mean, median, D05, and D01) of the target volumes, the OARs, the carotid arteries, and the thyroid compared with NCE-CT. Our results suggested that compared with NCE-CT planning, CE-CT scanning should be performed during IMRT for better target and OAR delineation, without discernible change in radiation doses.

  17. External Beam Radiation Therapy for Cancer

    Science.gov (United States)

    External beam radiation therapy is used to treat many types of cancer. it is a local treatment, where a machine aims radiation at your cancer. Learn more about different types of external beam radiation therapy, and what to expect if you're receiving treatment.

  18. Dosimetric Inhomogeneity Predicts for Long-Term Breast Pain After Breast-Conserving Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Mak, Kimberley S. [Harvard Radiation Oncology Program, Boston, Massachusetts (United States); Chen, Yu-Hui; Catalano, Paul J. [Department of Biostatistics and Computational Biology, Dana-Farber Cancer Institute, Boston, Massachusetts (United States); Punglia, Rinaa S.; Wong, Julia S.; Truong, Linh [Department of Radiation Oncology, Dana-Farber/Brigham and Women' s Cancer Center, Boston, Massachusetts (United States); Bellon, Jennifer R., E-mail: jbellon@LROC.harvard.edu [Department of Radiation Oncology, Dana-Farber/Brigham and Women' s Cancer Center, Boston, Massachusetts (United States)

    2015-12-01

    Purpose: The objective of this cross-sectional study was to characterize long-term breast pain in patients undergoing breast-conserving surgery and radiation (BCT) and to identify predictors of this pain. Methods and Materials: We identified 355 eligible patients with Tis-T2N0M0 breast cancer who underwent BCT in 2007 to 2011, without recurrent disease. A questionnaire derived from the Late Effects Normal Tissue Task Force (LENT) Subjective, Objective, Management, Analytic (SOMA) scale was mailed with 7 items detailing the severity, frequency, duration, and impact of ipsilateral breast pain over the previous 2 weeks. A logistic regression model identified predictors of long-term breast pain based on questionnaire responses and patient, disease, and treatment characteristics. Results: The questionnaire response rate was 80% (n=285). One hundred thirty-five patients (47%) reported pain in the treated breast, with 19 (14%) having pain constantly or at least daily; 15 (11%) had intense pain. The pain interfered with daily activities in 11 patients (8%). Six patients (4%) took analgesics for breast pain. Fourteen (10%) thought that the pain affected their quality of life. On univariable analysis, volume of breast tissue treated to ≥105% of the prescribed dose (odds ratio [OR] 1.001 per cc, 95% confidence interval [CI] 1.000-1.002; P=.045), volume treated to ≥110% (OR 1.009 per cc, 95% CI 1.002-1.016; P=.012), hormone therapy use (OR 1.95, 95% CI 1.12-3.39; P=.02), and other sites of pain (OR 1.79, 95% CI 1.05-3.07; P=.03) predicted for long-term breast pain. On multivariable analysis, volume ≥110% (OR 1.01 per cc, 95% CI 1.003-1.017; P=.007), shorter time since treatment (OR 0.98 per month, 95% CI 0.96-0.998; P=.03), and hormone therapy (OR 1.84, 95% CI 1.05-3.25; P=.03) were independent predictors of pain. Conclusion: Long-term breast pain was common after BCT. Although nearly half of patients had pain, most considered it tolerable. Dosimetric inhomogeneity

  19. Preliminary dosimetric methodology for a new cobalt-60 irradiator for radioinduced necrosis

    International Nuclear Information System (INIS)

    Moura, Eduardo S.; Mosca, Rodrigo C.; Zeituni, Carlos A.; Rostelato, Maria Elisa C.M.; Mathor, Monica B.; Sakuraba, Roberto K.; Goncalves, Vinicius D.

    2011-01-01

    The use of ionizing radiation in medical procedures, as radiotherapy, is a well-established clinical process and it has been used for several decades with good clinical results and continuous technology development for treatment optimization. On the contrary, some injuries such as necrosis, may occur with patients, due to wrong administration of the absorbed dose or with expected side effects. To evaluate how these injuries could be investigated and how they can be treated, a new Cobalto-60 irradiator was developed to induce radionecrosis in mice. This irradiator is composed by a cylindrical size and it was set up with eleven Cobalt-60 sources aligned in the surface of a cylindrical lead. This alignment guarantees a small dose focal area in a longitudinal table, with proper frames for positioning mice precisely during the irradiations period. The dosimetric procedure will measure the absorbed dose in the dose focal area, delimited the area of irradiation with penumbra regions (gradients absorbed dose profiles) and others anatomical regions of the mice with high radiosensitivity. Possible dosimetric procedures and related devices will be present in this work,. The obtained dosimetric data will be applied to ensure the accurate period of radiation of a given position. This preliminary study assures that the fundamental dosimetric process of this new Cobalt-60 irradiator and it predicates that dosimetric processes area feasible to be conducted. (author)

  20. Preliminary dosimetric methodology for a new cobalt-60 irradiator for radioinduced necrosis

    Energy Technology Data Exchange (ETDEWEB)

    Moura, Eduardo S.; Mosca, Rodrigo C.; Zeituni, Carlos A.; Rostelato, Maria Elisa C.M.; Mathor, Monica B., E-mail: esmoura@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Sakuraba, Roberto K.; Goncalves, Vinicius D. [Hospital Israelita Albert Einstein (HIAE), Sao Paulo, SP (Brazil)

    2011-07-01

    The use of ionizing radiation in medical procedures, as radiotherapy, is a well-established clinical process and it has been used for several decades with good clinical results and continuous technology development for treatment optimization. On the contrary, some injuries such as necrosis, may occur with patients, due to wrong administration of the absorbed dose or with expected side effects. To evaluate how these injuries could be investigated and how they can be treated, a new Cobalto-60 irradiator was developed to induce radionecrosis in mice. This irradiator is composed by a cylindrical size and it was set up with eleven Cobalt-60 sources aligned in the surface of a cylindrical lead. This alignment guarantees a small dose focal area in a longitudinal table, with proper frames for positioning mice precisely during the irradiations period. The dosimetric procedure will measure the absorbed dose in the dose focal area, delimited the area of irradiation with penumbra regions (gradients absorbed dose profiles) and others anatomical regions of the mice with high radiosensitivity. Possible dosimetric procedures and related devices will be present in this work,. The obtained dosimetric data will be applied to ensure the accurate period of radiation of a given position. This preliminary study assures that the fundamental dosimetric process of this new Cobalt-60 irradiator and it predicates that dosimetric processes area feasible to be conducted. (author)

  1. Understanding the dosimetric powder EPR spectrum of sucrose by identification of the stable radiation-induced radicals

    International Nuclear Information System (INIS)

    Vrielinck, H.; Vanhaelewyn, G.; Matthys, P.; Callens, F.; Kusakovskij, J.

    2014-01-01

    Sucrose, the main component of table sugar, present in nearly every household and quite radiation sensitive, is considered as an interesting emergency dosemeter. Another application of radiation-induced radicals in sugars is the detection of irradiation in sugar-containing foodstuffs. The complexity of electron paramagnetic resonance (EPR) spectra of radicals in these materials, as a result of many hyperfine interactions and the multi-compositeness of the spectra of individual sugars, complicate dose assessment and the improvement of protocols for control and identification of irradiated sugar-containing foodstuffs using EPR. A thorough understanding of the EPR spectrum of individual irradiated sugars is desirable when one wants to reliably use them in a wide variety of dosimetric applications. Recently, the dominant room temperature stable radicals in irradiated sucrose have been thoroughly characterised using EPR, electron nuclear double resonance (ENDOR) and ENDOR-induced EPR. These radicals were structurally identified by comparing their proton hyperfine and g-tensors with the results of Density Functional Theory calculations for test radical structures. In this paper, the authors use the spin Hamiltonian parameters determined in these studies to simulate powder EPR spectra at the standard X-band (9.5 GHz), commonly used in applications, and at higher frequencies, up to J-band (285 GHz), rendering spectra with higher resolution. A few pitfalls in the simulation process are highlighted. The results indicate that the major part of the dosimetric spectrum can be understood in terms of three dominant radicals, but as-yet unidentified radicals also contribute in a non-negligible way. (authors)

  2. Comparison of the performance between portal dosimetry and a commercial two-dimensional array system on pretreatment quality assurance for volumetric-modulated arc and intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Kim, Yon-Lae; Chung, Jin-Beom; Kim, Jae-Sung; Lee, Jeong-Woo; Choi, Kyoung-Sik

    2014-01-01

    The aim of this study was to compare the dosimetric performance and to evaluate the pretreatment quality assurance (QA) of a portal dosimetry and a commercial two-dimensional (2-D) array system. In the characteristics comparison study, the measured values for the dose linearity, dose rate response, reproducibility, and field size dependence for 6-MV photon beams were analyzed for both detector systems. To perform the qualitative evaluations of the 10 IMRT and the 10 VMAT plans, we used the Gamma index for quantifying the agreement between calculations and measurements. The performance estimates for both systems show that overall, minimal differences in the dosimetric characteristics exist between the Electron portal imaging device (EPID) and 2-D array system. In the qualitative analysis for pretreatment quality assurance, the EPID and 2-D array system yield similar passing rate results for the majority of clinical Intensity-modulated radiation therapy (IMRT) and Volumetric-modulated arc therapy (VMAT) cases. These results were satisfactory for IMRT and VMAT fields and were within the acceptable criteria of γ % ≤1, γ avg < 0.5. The EPDI and the 2-D array systems showed comparable dosimetric results. In this study, the results revealed both systems to be suitable for patient-specific QA measurements for IMRT and VMAT. We conclude that, depending on the status of clinic, both systems can be used interchangeably for routine pretreatment QA.

  3. Comparison of the performance between portal dosimetry and a commercial two-dimensional array system on pretreatment quality assurance for volumetric-modulated arc and intensity-modulated radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yon-Lae [Choonhae College of Health Sciences, Ulsan (Korea, Republic of); The Catholic University of Korea, Seoul (Korea, Republic of); Chung, Jin-Beom; Kim, Jae-Sung [Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); Lee, Jeong-Woo [Konkuk University Medical Center, Seoul (Korea, Republic of); Choi, Kyoung-Sik [SAM Anyang Hospital, Anyang (Korea, Republic of)

    2014-04-15

    The aim of this study was to compare the dosimetric performance and to evaluate the pretreatment quality assurance (QA) of a portal dosimetry and a commercial two-dimensional (2-D) array system. In the characteristics comparison study, the measured values for the dose linearity, dose rate response, reproducibility, and field size dependence for 6-MV photon beams were analyzed for both detector systems. To perform the qualitative evaluations of the 10 IMRT and the 10 VMAT plans, we used the Gamma index for quantifying the agreement between calculations and measurements. The performance estimates for both systems show that overall, minimal differences in the dosimetric characteristics exist between the Electron portal imaging device (EPID) and 2-D array system. In the qualitative analysis for pretreatment quality assurance, the EPID and 2-D array system yield similar passing rate results for the majority of clinical Intensity-modulated radiation therapy (IMRT) and Volumetric-modulated arc therapy (VMAT) cases. These results were satisfactory for IMRT and VMAT fields and were within the acceptable criteria of γ{sub %}≤1, γ{sub avg} < 0.5. The EPDI and the 2-D array systems showed comparable dosimetric results. In this study, the results revealed both systems to be suitable for patient-specific QA measurements for IMRT and VMAT. We conclude that, depending on the status of clinic, both systems can be used interchangeably for routine pretreatment QA.

  4. Initial Report of Pencil Beam Scanning Proton Therapy for Posthysterectomy Patients With Gynecologic Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Lilie L., E-mail: lin@xrt.upenn.edu; Kirk, Maura; Scholey, Jessica; Taku, Nicolette; Kiely, Janid B.; White, Benjamin; Both, Stefan

    2016-05-01

    Purpose: To report the acute toxicities associated with pencil beam scanning proton beam radiation therapy (PBS) for whole pelvis radiation therapy in women with gynecologic cancers and the results of a dosimetric comparison of PBS versus intensity modulated radiation therapy (IMRT) plans. Methods and Materials: Eleven patients with posthysterectomy gynecologic cancer received PBS to the whole pelvis. The patients received a dose of 45 to 50.4 Gy relative biological effectiveness (RBE) in 1.8 Gy (RBE) daily fractions. Acute toxicity was scored according to the Common Terminology Criteria for Adverse Events, version 4. A dosimetric comparison between a 2-field posterior oblique beam PBS and an IMRT plan was conducted. The Wilcoxon signed rank test was used to assess the potential dosimetric differences between the 2 plans and PBS target coverage robustness relative to setup uncertainties. Results: The median patient age was 55 years (range 23-76). The primary site was cervical in 7, vaginal in 1, and endometrial in 3. Of the 11 patients, 7 received concurrent cisplatin, 1 each received sandwich carboplatin and paclitaxel chemotherapy, both sandwich and concurrent chemotherapy, and concurrent and adjuvant chemotherapy, and 1 received no chemotherapy. All patients completed treatment. Of the 9 patients who received concurrent chemotherapy, the rate of grade 2 and 3 hematologic toxicities was 33% and 11%, respectively. One patient (9%) developed grade 3 acute gastrointestinal toxicity; no patient developed grade ≥3 genitourinary toxicity. The volume of pelvic bone marrow, bladder, and small bowel receiving 10 to 30 Gy was significantly lower with PBS than with intensity modulated radiation therapy (P<.001). The target coverage for all PBS plans was robust relative to the setup uncertainties (P>.05) with the clinical target volume mean dose percentage received by 95% and 98% of the target volume coverage changes within 2% for the individual plans. Conclusions: Our

  5. Neutron therapy coupling brachytherapy and boron neutron capture therapy (BNCT) techniques

    International Nuclear Information System (INIS)

    Chaves, Iara Ferreira.

    1994-12-01

    In the present dissertation, neutron radiation techniques applied into organs of the human body are investigated as oncologic radiation therapy. The proposal treatment consists on connecting two distinct techniques: Boron Neutron Capture Therapy (BNCT) and irradiation by discrete sources of neutrons, through the brachytherapy conception. Biological and radio-dosimetrical aspects of the two techniques are considered. Nuclear aspects are discussed, presenting the nuclear reactions occurred in tumoral region, and describing the forms of evaluating the dose curves. Methods for estimating radiation transmission are reviewed through the solution of the neutron transport equation, Monte Carlo methodology, and simplified analytical calculation based on diffusion equation and numerical integration. The last is computational developed and presented as a quickly way to neutron transport evaluation in homogeneous medium. The computational evaluation of the doses for distinct hypothetical situations is presented, applying the coupled techniques BNTC and brachytherapy as an possible oncologic treatment. (author). 78 refs., 61 figs., 21 tabs

  6. Reducing the Cost of Proton Radiation Therapy: The Feasibility of a Streamlined Treatment Technique for Prostate Cancer

    International Nuclear Information System (INIS)

    Newhauser, Wayne D.; Zhang, Rui; Jones, Timothy G.; Giebeler, Annelise; Taddei, Phillip J.; Stewart, Robert D.; Lee, Andrew; Vassiliev, Oleg

    2015-01-01

    Proton radiation therapy is an effective modality for cancer treatments, but the cost of proton therapy is much higher compared to conventional radiotherapy and this presents a formidable barrier to most clinical practices that wish to offer proton therapy. Little attention in literature has been paid to the costs associated with collimators, range compensators and hypofractionation. The objective of this study was to evaluate the feasibility of cost-saving modifications to the present standard of care for proton treatments for prostate cancer. In particular, we quantified the dosimetric impact of a treatment technique in which custom fabricated collimators were replaced with a multileaf collimator (MLC) and the custom range compensators (RC) were eliminated. The dosimetric impacts of these modifications were assessed for 10 patients with a commercial treatment planning system (TPS) and confirmed with corresponding Monte Carlo simulations. We assessed the impact on lifetime risks of radiogenic second cancers using detailed dose reconstructions and predictive dose-risk models based on epidemiologic data. We also performed illustrative calculations, using an isoeffect model, to examine the potential for hypofractionation. Specifically, we bracketed plausible intervals of proton fraction size and total treatment dose that were equivalent to a conventional photon treatment of 79.2 Gy in 44 fractions. Our results revealed that eliminating the RC and using an MLC had negligible effect on predicted dose distributions and second cancer risks. Even modest hypofractionation strategies can yield substantial cost savings. Together, our results suggest that it is feasible to modify the standard of care to increase treatment efficiency, reduce treatment costs to patients and insurers, while preserving high treatment quality

  7. Reducing the Cost of Proton Radiation Therapy: The Feasibility of a Streamlined Treatment Technique for Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Newhauser, Wayne D., E-mail: newhauser@lsu.edu [Department of Physics and Astronomy, Louisiana State University, 202 Nicholson Hall, Baton Rouge, LA 70803 (United States); Department of Physics, Mary Bird Perkins Cancer Center, 4950 Essen Lane, Baton Rouge, LA 70809 (United States); Zhang, Rui [Department of Physics and Astronomy, Louisiana State University, 202 Nicholson Hall, Baton Rouge, LA 70803 (United States); Department of Physics, Mary Bird Perkins Cancer Center, 4950 Essen Lane, Baton Rouge, LA 70809 (United States); Departments of Radiation Physics and Radiation Oncology, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd, Houston, TX 77030 (United States); The University of Texas Graduate School of Biomedical Sciences, Houston, TX 77030 (United States); Jones, Timothy G. [Departments of Radiation Physics and Radiation Oncology, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd, Houston, TX 77030 (United States); The University of Texas Graduate School of Biomedical Sciences, Houston, TX 77030 (United States); Department of Physics, Abilene Christian University, ACU Box 27963, Abilene, TX 79699 (United States); Giebeler, Annelise; Taddei, Phillip J. [Departments of Radiation Physics and Radiation Oncology, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd, Houston, TX 77030 (United States); The University of Texas Graduate School of Biomedical Sciences, Houston, TX 77030 (United States); Stewart, Robert D. [Department of Radiation Oncology, University of Washington School of Medicine, 1959 NE Pacific Street, Box 356043, Seattle, WA 98195 (United States); Lee, Andrew [Departments of Radiation Physics and Radiation Oncology, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd, Houston, TX 77030 (United States); Vassiliev, Oleg [Department of Physics and Astronomy, Louisiana State University, 202 Nicholson Hall, Baton Rouge, LA 70803 (United States); Department of Physics, Mary Bird Perkins Cancer Center, 4950 Essen Lane, Baton Rouge, LA 70809 (United States)

    2015-04-24

    Proton radiation therapy is an effective modality for cancer treatments, but the cost of proton therapy is much higher compared to conventional radiotherapy and this presents a formidable barrier to most clinical practices that wish to offer proton therapy. Little attention in literature has been paid to the costs associated with collimators, range compensators and hypofractionation. The objective of this study was to evaluate the feasibility of cost-saving modifications to the present standard of care for proton treatments for prostate cancer. In particular, we quantified the dosimetric impact of a treatment technique in which custom fabricated collimators were replaced with a multileaf collimator (MLC) and the custom range compensators (RC) were eliminated. The dosimetric impacts of these modifications were assessed for 10 patients with a commercial treatment planning system (TPS) and confirmed with corresponding Monte Carlo simulations. We assessed the impact on lifetime risks of radiogenic second cancers using detailed dose reconstructions and predictive dose-risk models based on epidemiologic data. We also performed illustrative calculations, using an isoeffect model, to examine the potential for hypofractionation. Specifically, we bracketed plausible intervals of proton fraction size and total treatment dose that were equivalent to a conventional photon treatment of 79.2 Gy in 44 fractions. Our results revealed that eliminating the RC and using an MLC had negligible effect on predicted dose distributions and second cancer risks. Even modest hypofractionation strategies can yield substantial cost savings. Together, our results suggest that it is feasible to modify the standard of care to increase treatment efficiency, reduce treatment costs to patients and insurers, while preserving high treatment quality.

  8. Beam angle optimization for intensity-modulated radiation therapy using a guided pattern search method

    International Nuclear Information System (INIS)

    Rocha, Humberto; Dias, Joana M; Ferreira, Brígida C; Lopes, Maria C

    2013-01-01

    Generally, the inverse planning of radiation therapy consists mainly of the fluence optimization. The beam angle optimization (BAO) in intensity-modulated radiation therapy (IMRT) consists of selecting appropriate radiation incidence directions and may influence the quality of the IMRT plans, both to enhance better organ sparing and to improve tumor coverage. However, in clinical practice, most of the time, beam directions continue to be manually selected by the treatment planner without objective and rigorous criteria. The goal of this paper is to introduce a novel approach that uses beam’s-eye-view dose ray tracing metrics within a pattern search method framework in the optimization of the highly non-convex BAO problem. Pattern search methods are derivative-free optimization methods that require a few function evaluations to progress and converge and have the ability to better avoid local entrapment. The pattern search method framework is composed of a search step and a poll step at each iteration. The poll step performs a local search in a mesh neighborhood and ensures the convergence to a local minimizer or stationary point. The search step provides the flexibility for a global search since it allows searches away from the neighborhood of the current iterate. Beam’s-eye-view dose metrics assign a score to each radiation beam direction and can be used within the pattern search framework furnishing a priori knowledge of the problem so that directions with larger dosimetric scores are tested first. A set of clinical cases of head-and-neck tumors treated at the Portuguese Institute of Oncology of Coimbra is used to discuss the potential of this approach in the optimization of the BAO problem. (paper)

  9. Clinical Implementation of Intrafraction Cone Beam Computed Tomography Imaging During Lung Tumor Stereotactic Ablative Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Li, Ruijiang; Han, Bin; Meng, Bowen [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Maxim, Peter G.; Xing, Lei; Koong, Albert C. [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, California (United States); Diehn, Maximilian, E-mail: Diehn@Stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, California (United States); Institute for Stem Cell Biology and Regenerative Medicine, Stanford University School of Medicine, Stanford, California (United States); Loo, Billy W., E-mail: BWLoo@Stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, California (United States)

    2013-12-01

    Purpose: To develop and clinically evaluate a volumetric imaging technique for assessing intrafraction geometric and dosimetric accuracy of stereotactic ablative radiation therapy (SABR). Methods and Materials: Twenty patients received SABR for lung tumors using volumetric modulated arc therapy (VMAT). At the beginning of each fraction, pretreatment cone beam computed tomography (CBCT) was used to align the soft-tissue tumor position with that in the planning CT. Concurrent with dose delivery, we acquired fluoroscopic radiograph projections during VMAT using the Varian on-board imaging system. Those kilovolt projections acquired during millivolt beam-on were automatically extracted, and intrafraction CBCT images were reconstructed using the filtered backprojection technique. We determined the time-averaged target shift during VMAT by calculating the center of mass of the tumor target in the intrafraction CBCT relative to the planning CT. To estimate the dosimetric impact of the target shift during treatment, we recalculated the dose to the GTV after shifting the entire patient anatomy according to the time-averaged target shift determined earlier. Results: The mean target shift from intrafraction CBCT to planning CT was 1.6, 1.0, and 1.5 mm; the 95th percentile shift was 5.2, 3.1, 3.6 mm; and the maximum shift was 5.7, 3.6, and 4.9 mm along the anterior-posterior, left-right, and superior-inferior directions. Thus, the time-averaged intrafraction gross tumor volume (GTV) position was always within the planning target volume. We observed some degree of target blurring in the intrafraction CBCT, indicating imperfect breath-hold reproducibility or residual motion of the GTV during treatment. By our estimated dose recalculation, the GTV was consistently covered by the prescription dose (PD), that is, V100% above 0.97 for all patients, and minimum dose to GTV >100% PD for 18 patients and >95% PD for all patients. Conclusions: Intrafraction CBCT during VMAT can provide

  10. Comparison of dose-volume histograms for Tomo therapy, linear accelerator-based 3D conformal radiation therapy, and intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Ji, Youn-Sang; Dong, Kyung-Rae; Kim, Chang-Bok; Choi, Seong-Kwan; Chung, Woon-Kwan; Lee, Jong-Woong

    2011-01-01

    Highlights: → Evaluation of DVH from 3D CRT, IMRT and Tomo therapy was conducted for tumor therapy. → The doses of GTV and CTV were compared using DVHs from 3D CRT, IMRT and Tomo therapy. → The GTV was higher when Tomo therapy was used, while the doses of critical organ were low. → They said that Tomo therapy satisfied the goal of radiation therapy more than the others. - Abstract: Evaluation of dose-volume histograms from three-dimensional conformal radiation therapy (3D CRT), intensity-modulated radiation therapy (IMRT), and Tomo therapy was conducted. These three modalities are among the diverse treatment systems available for tumor therapy. Three patients who received tumor therapy for a malignant oligodendroglioma in the cranium, nasopharyngeal carcinoma in the cervical neck, and prostate cancer in the pelvis were selected as study subjects. Therapy plans were made for the three patients before dose-volume histograms were obtained. The doses of the gross tumor volume (GTV) and the clinical target volume (CTV) were compared using the dose-volume histograms obtained from the LINAC-based 3D CRT, IMRT planning station (Varian Eclipse-Varian, version 8.1), and Tomo therapy planning station. In addition, the doses of critical organs in the cranium, cervix, and pelvis that should be protected were compared. The GTV was higher when Tomo therapy was used compared to 3D CRT and the LINAC-based IMRT, while the doses of critical organ tissues that required protection were low. These results demonstrated that Tomo therapy satisfied the ultimate goal of radiation therapy more than the other therapies.

  11. Radiation therapy for metastatic spinal tumors

    International Nuclear Information System (INIS)

    Kida, Akio; Fukuda, Haruyuki; Taniguchi, Shuji; Sakai, Kazuaki

    2000-01-01

    The results of radiation therapy for metastatic spinal tumors were evaluated in terms of pain relief, improvement of neurological impairment, and survival. Between 1986 and 1995, 52 symptomatic patients with metastatic spinal tumors treated with radiation therapy were evaluated. The patients all received irradiation of megavoltage energy. Therapeutic efficacy was evaluated in terms of pain relief and improvement of neurological impairment. Pain relief was observed in 29 (61.7%) of 47 patients with pain. Therapy was effective for 17 (70.8%) of 24 patients without neurological impairment, and efficacy was detected in 12 (52.2%) of 23 patients with neurological impairment. Improvement of neurological symptoms was obtained in seven (25.0%) of 28 patients with neurological impairment. Radiation therapy was effective for pain relief in patients with metastatic spinal tumors. In patients with neurological impairment, less pain relief was observed than in those without impairment. Improvement of neurological impairment was restricted, but radiation therapy was thought to be effective in some cases in the early stage of neurological deterioration. Radiation therapy for metastatic spinal tumors contraindicated for surgery was considered effective for improvement of patients' activities of daily living. (author)

  12. Radiation therapy in the treatment of hilar cholangiocarcinoma

    International Nuclear Information System (INIS)

    Jing Jin; Zhai Renyou

    2007-01-01

    The incidence of hilar cholangiocarcinoma is very rare worldwide. Radical resection is the only prognostic factor for long survival in patients with hilar cholangiocarcinoma. Postoperative radiation therapy can improve local control and survival rates for patients with palliative resection, but it remains controversial in patients with radical resection. Biliary drainage can effectively release bile duct obstruction for the majority of patients with locally advanced disease, and may even prolong survival when combined with radiation therapy. Radiation therapy includes extrernal beam therapy alone, external beam therapy with intraluminal brachytheapy and new radiation technique, such as three dimentional conformal therapy and intensity modulated radiation therapy. The propective randomized clinical study is needed for further investigation in the role of combined modality therapy especially for hilar cholangiocarcinoma. (authors)

  13. Dosimetric and deformation effects of image-guided interventions during stereotactic body radiation therapy of the prostate using an endorectal balloon

    International Nuclear Information System (INIS)

    Jones, Bernard L.; Gan, Gregory; Diot, Quentin; Kavanagh, Brian; Timmerman, Robert D.; Miften, Moyed

    2012-01-01

    Purpose: During stereotactic body radiation therapy (SBRT) for the treatment of prostate cancer, an inflatable endorectal balloon (ERB) may be used to reduce motion of the target and reduce the dose to the posterior rectal wall. This work assessed the dosimetric impact of manual interventions on ERB position in patients receiving prostate SBRT and investigated the impact of ERB interventions on prostate shape. Methods: The data of seven consecutive patients receiving SBRT for the treatment of clinical stage T1cN0M0 prostate cancer enrolled in a multi-institutional, IRB-approved trial were analyzed. The SBRT dose was 50 Gy in five fractions to a planning target volume (PTV) that included the prostate (implanted with three fiducial markers) with a 3–5 mm margin. All plans were based on simulation images that included an ERB inflated with 60 cm 3 of air. Daily kilovoltage cone-beam computed tomography (CBCT) imaging was performed to localize the PTV, and an automated fusion with the planning images yielded displacements required for PTV relocalization. When the ERB volume and/or position were judged to yield inaccurate repositioning, manual adjustment (ERB reinflation and/or repositioning) was performed. Based on all 59 CBCT image sets acquired, a deformable registration algorithm was used to determine the dose received by, displacement of, and deformation of the prostate, bladder (BLA), and anterior rectal wall (ARW). This dose tracking methodology was applied to images taken before and after manual adjustment of the ERB (intervention), and the delivered dose was compared to that which would have been delivered in the absence of intervention. Results: Interventions occurred in 24 out of 35 (69%) of the treated fractions. The direct effect of these interventions was an increase in the prostate radiation dose that included 95% of the PTV (D95) from 9.6 ± 1.0 to 10.0 ± 0.2 Gy (p = 0.06) and an increase in prostate coverage from 94.0% ± 8.5% to 97.8% ± 1.9% (p = 0

  14. Dosimetric properties of MOS transistors

    International Nuclear Information System (INIS)

    Frank, H.; Petr, I.

    1977-01-01

    The structure of MOS transistors is described and their characteristics given. The experiments performed and data in the literature show the following dosimetric properties of MOS transistors: while for low gamma doses the transistor response to exposure is linear, it shows saturation for higher doses (exceeding 10 3 Gy in tissue). The response is independent of the energy of radiation and of the dose rate (within 10 -2 to 10 5 Gy/s). The spontaneous reduction with time of the spatial charge captured by the oxide layer (fading) is small and acceptable from the point of view of dosimetry. Curves are given of isochronous annealing of the transistors following irradiation with 137 Cs and 18 MeV electrons for different voltages during irradiation. The curves show that in MOS transistors irradiated with high-energy electrons the effect of annealing is less than in transistors irradiated with 137 Cs. In view of the requirement of using higher temperatures (approx. 400 degC) for the complete ''erasing'' of the captured charge, unsealed systems must be used for dosimetric purposes. The effect was also studied of neutron radiation, proton radiation and electron radiation on the MOS transistor structure. For MOS transistor irradiation with 14 MeV neutrons from a neutron generator the response was 4% of that for gamma radiation at the same dose equivalent. The effect of proton radiation was studied as related to the changes in MOS transistor structure during space flights. The response curve shapes are similar to those of gamma radiation curves. The effect of electron radiation on the MOS structure was studied by many authors. The experiments show that for each thickness of the SiO 2 layer an electron energy exists at which the size of the charge captured in SiO 2 is the greatest. All data show that MOS transistors are promising for radiation dosimetry. The main advantage of MOS transistors as gamma dosemeters is the ease and speed of evaluation, low sensitivity to neutron

  15. Intensity-Modulated Radiation Therapy With Concurrent Chemotherapy as Preoperative Treatment for Localized Gastric Adenocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Chakravarty, Twisha; Crane, Christopher H. [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Ajani, Jaffer A. [Department of Gastrointestinal Medical Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Mansfield, Paul F. [Department of Surgical Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Briere, Tina M.; Beddar, A. Sam [Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Mok, Henry; Reed, Valerie K.; Krishnan, Sunil; Delclos, Marc E. [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Das, Prajnan, E-mail: PrajDas@mdanderson.org [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States)

    2012-06-01

    Purpose: The goal of this study was to evaluate dosimetric parameters, acute toxicity, pathologic response, and local control in patients treated with preoperative intensity-modulated radiation therapy (IMRT) and concurrent chemotherapy for localized gastric adenocarcinoma. Methods: Between November 2007 and April 2010, 25 patients with localized gastric adenocarcinoma were treated with induction chemotherapy, followed by preoperative IMRT and concurrent chemotherapy and, finally, surgical resection. The median radiation therapy dose was 45 Gy. Concurrent chemotherapy was 5-fluorouracil and oxaliplatin in 18 patients, capecitabine in 3, and other regimens in 4. Subsequently, resection was performed with total gastrectomy in 13 patients, subtotal gastrectomy in 7, and other surgeries in 5. Results: Target coverage, expressed as the ratio of the minimum dose received by 99% of the planning target volume to the prescribed dose, was a median of 0.97 (range, 0.92-1.01). The median V{sub 30} (percentage of volume receiving at least 30 Gy) for the liver was 26%; the median V{sub 20} (percentage of volume receiving at least 20 Gy) for the right and left kidneys was 14% and 24%, respectively; and the median V{sub 40} (percentage of volume receiving at least 40 Gy) for the heart was 18%. Grade 3 acute toxicity developed in 14 patients (56%), including dehydration in 10, nausea in 8, and anorexia in 5. Grade 4 acute toxicity did not develop in any patient. There were no significant differences in the rates of acute toxicity, hospitalization, or feeding tube use in comparison to those in a group of 50 patients treated with preoperative three-dimensional conformal radiation therapy with concurrent chemotherapy. R0 resection was obtained in 20 patients (80%), and pathologic complete response occurred in 5 (20%). Conclusions: Preoperative IMRT for gastric adenocarcinoma was well tolerated, accomplished excellent target coverage and normal structure sparing, and led to appropriate

  16. Intensity-Modulated Radiation Therapy With Concurrent Chemotherapy as Preoperative Treatment for Localized Gastric Adenocarcinoma

    International Nuclear Information System (INIS)

    Chakravarty, Twisha; Crane, Christopher H.; Ajani, Jaffer A.; Mansfield, Paul F.; Briere, Tina M.; Beddar, A. Sam; Mok, Henry; Reed, Valerie K.; Krishnan, Sunil; Delclos, Marc E.; Das, Prajnan

    2012-01-01

    Purpose: The goal of this study was to evaluate dosimetric parameters, acute toxicity, pathologic response, and local control in patients treated with preoperative intensity-modulated radiation therapy (IMRT) and concurrent chemotherapy for localized gastric adenocarcinoma. Methods: Between November 2007 and April 2010, 25 patients with localized gastric adenocarcinoma were treated with induction chemotherapy, followed by preoperative IMRT and concurrent chemotherapy and, finally, surgical resection. The median radiation therapy dose was 45 Gy. Concurrent chemotherapy was 5-fluorouracil and oxaliplatin in 18 patients, capecitabine in 3, and other regimens in 4. Subsequently, resection was performed with total gastrectomy in 13 patients, subtotal gastrectomy in 7, and other surgeries in 5. Results: Target coverage, expressed as the ratio of the minimum dose received by 99% of the planning target volume to the prescribed dose, was a median of 0.97 (range, 0.92–1.01). The median V 30 (percentage of volume receiving at least 30 Gy) for the liver was 26%; the median V 20 (percentage of volume receiving at least 20 Gy) for the right and left kidneys was 14% and 24%, respectively; and the median V 40 (percentage of volume receiving at least 40 Gy) for the heart was 18%. Grade 3 acute toxicity developed in 14 patients (56%), including dehydration in 10, nausea in 8, and anorexia in 5. Grade 4 acute toxicity did not develop in any patient. There were no significant differences in the rates of acute toxicity, hospitalization, or feeding tube use in comparison to those in a group of 50 patients treated with preoperative three-dimensional conformal radiation therapy with concurrent chemotherapy. R0 resection was obtained in 20 patients (80%), and pathologic complete response occurred in 5 (20%). Conclusions: Preoperative IMRT for gastric adenocarcinoma was well tolerated, accomplished excellent target coverage and normal structure sparing, and led to appropriate pathologic

  17. Low level laser therapy/photobiomodulation in the management of side effects of chemoradiation therapy in head and neck cancer: part 1: mechanisms of action, dosimetric, and safety considerations

    Science.gov (United States)

    Zecha, Judith A. E. M.; Raber-Durlacher, Judith E.; Nair, Raj G.; Epstein, Joel B.; Sonis, Stephen T.; Elad, Sharon; Hamblin, Michael R.; Barasch, Andrei; Migliorati, Cesar A.; Milstein, Dan M. J.; Genot, Marie-Thérèse; Lansaat, Liset; van der Brink, Ron; Arnabat-Dominguez, Josep; van der Molen, Lisette; Jacobi, Irene; van Diessen, Judi; de Lange, Jan; Smeele, Ludi E.; Schubert, Mark M.

    2016-01-01

    Purpose There is a large body of evidence supporting the efficacy of low level laser therapy (LLLT), more recently termed photobiomodulation (PBM), for the management of oral mucositis (OM) in patients undergoing radiotherapy for head and neck cancer (HNC). Recent advances in PBM technology, together with a better understanding of mechanisms involved, may expand the applications for PBM in the management of other complications associated with HNC treatment. This article (part 1) describes PBM mechanisms of action, dosimetry, and safety aspects and, in doing so, provides a basis for a companion paper (part 2) which describes the potential breadth of potential applications of PBM in the management of side-effects of (chemo)radiation therapy in patients being treated for HNC and proposes PBM parameters. Methods This study is a narrative non-systematic review. Results We review PBM mechanisms of action and dosimetric considerations. Virtually, all conditions modulated by PBM (e.g., ulceration, inflammation, lymphedema, pain, fibrosis, neurological and muscular injury) are thought to be involved in the pathogenesis of (chemo)radiation therapy-induced complications in patients treated for HNC. The impact of PBM on tumor behavior and tumor response to treatment has been insufficiently studied. In vitro studies assessing the effect of PBM on tumor cells report conflicting results, perhaps attributable to inconsistencies of PBM power and dose. Nonetheless, the biological bases for the broad clinical activities ascribed to PBM have also been noted to be similar to those activities and pathways associated with negative tumor behaviors and impeded response to treatment. While there are no anecdotal descriptions of poor tumor outcomes in patients treated with PBM, confirming its neutrality with respect to cancer responsiveness is a critical priority. Conclusion Based on its therapeutic effects, PBM may have utility in a broad range of oral, oropharyngeal, facial, and neck

  18. Clinical experience of radiation therapy for Graves` ophthalmopathy

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Takeo; Mitsuhashi, Norio; Nagashima, Hisako; Sakurai, Hideyuki; Murata, Osamu; Ishizeki, Kei; Shimaya, Sanae; Hayakawa, Kazushige; Niibe, Hideo [Gunma Univ., Maebashi (Japan). School of Medicine

    1996-11-01

    The effect of radiation therapy for Graves` ophthalmopathy was evaluated. Ten patients with Graves` ophthalmopathy were treated with radiation therapy between 1992 and 1993 in Gunma University Hospital. All patients had a past history of hyperthyroidism and received 2,000 cGy to the retrobulbar tissues in 20 fractions. Nine of ten patients were treated with radiation therapy after the failure of corticosteroids. Six patients (60%) showed good or excellent responses. The exophthalmos type was more responsive to radiation therapy than the double vision type in this series. Two of five patients with the exophthalmos type demonstrated excellent responses, and their symptoms disappeared almost completely. The improvement of symptoms appeared within 3-6 months, and obvious clinical effects were demonstrated after 6 months of radiotherapy. Radiation therapy was well tolerated, and we have not observed any side effects of radiation therapy. In conclusion, radiation therapy is effective treatment for Graves` ophthalmopathy. (author)

  19. Clinical experience of radiation therapy for Graves' ophthalmopathy

    International Nuclear Information System (INIS)

    Takahashi, Takeo; Mitsuhashi, Norio; Nagashima, Hisako; Sakurai, Hideyuki; Murata, Osamu; Ishizeki, Kei; Shimaya, Sanae; Hayakawa, Kazushige; Niibe, Hideo

    1996-01-01

    The effect of radiation therapy for Graves' ophthalmopathy was evaluated. Ten patients with Graves' ophthalmopathy were treated with radiation therapy between 1992 and 1993 in Gunma University Hospital. All patients had a past history of hyperthyroidism and received 2,000 cGy to the retrobulbar tissues in 20 fractions. Nine of ten patients were treated with radiation therapy after the failure of corticosteroids. Six patients (60%) showed good or excellent responses. The exophthalmos type was more responsive to radiation therapy than the double vision type in this series. Two of five patients with the exophthalmos type demonstrated excellent responses, and their symptoms disappeared almost completely. The improvement of symptoms appeared within 3-6 months, and obvious clinical effects were demonstrated after 6 months of radiotherapy. Radiation therapy was well tolerated, and we have not observed any side effects of radiation therapy. In conclusion, radiation therapy is effective treatment for Graves' ophthalmopathy. (author)

  20. Radiation therapy for carcinoma of the endometrium

    International Nuclear Information System (INIS)

    Potish, R.A.

    1987-01-01

    Carcinoma of the endometrium is the most common malignant tumor in the female genital tract. Radiation therapy continues to play a major role in the management of endometrial carcinoma, both as primary therapy and as adjuvant treatment. The utility of pelvic external beam therapy and intracavitary therapy is long established. However, the modern era of surgical staging has lead to an appreciation of the role of radiation therapy beyond the pelvis. Radiation therapy has been shown to be of particular benefit in peritoneal and nodal spread. The classic management of endometrial cancer is reviewed and relatively new and somewhat controversial topics, such as preoperative intracavitary therapy followed by external beam therapy are discussed

  1. X-ray and radium gamma radiation injuries

    International Nuclear Information System (INIS)

    Fokkema, R.E.

    1993-05-01

    During the period 1896-1939 a number of maxima could be distinguished in the incidence of X-ray and radium gamma ray injuries in patients. An explanation for these fluctuations is investigated in this study. The first distinguishable maximum in the number of reported cases of X-ray injuries can be found in the period 1896-1897 and mainly concerns skin lesions, caused by the lack of shielding and ignorance of the effects. In the period 1904-1905 there was once again an apparent prevalence of radiation injuries to patients. After 1905 the incidence of radiation injuries decreased due to a wider use of dosimetric methods. The third phase of increased injuries may be subdivided into three components. In diagnostic roentgenology from 1896 to 1926 a number of causes of roentgen burns persisted: multiple or long exposures, the use of a short focus-skin-distance and a lack of suitable dosimetric methods. The reduction of complications after 1923 can be attributed to several factors: systematic training of physics who wished to become roentgenologists, greater care of doctors, the use of an alternative method of radiotherapy according to Coutard's method, the introduction of dosimetry with ionization chambers (after 1924), the consensus reached over the roentgen as a unit of applied dosage (in 1928), and the introduction of absorption curves for radiation quality (in 1933). Around 1920 a high complication rate arose as a result of exposure to radiation emitted by radium. In 1922 the first reliable radium dosimetry method came available. This applied to external radium therapy by regular shaped applicators. After 1938 reliable dosimetry was achieved in the field of interstitial radium therapy (brachytherapy). Injuries from radium therapy, however, persisted till about 1940, caused not only by the delayed availability of radium dosimetry, but also to the use of radium therapy by poorly trained radium therapists. 28 figs., 5 tabs

  2. Dosimetry through the Secondary Laboratory of Dosimetric Calibration of Mexico

    International Nuclear Information System (INIS)

    Tovar M, V.M.; Alvarez R, J.T.; Medina O, V.P.; Vergara M, F.; Anaya M, R.; Cejudo A, J.; Salinas L, B.

    2004-01-01

    In the beginnings of the sixty years an urgent necessity is presented mainly in the developing countries, of improving in important form the accuracy in the dosimetry of external faces in therapy of radiations (radiotherapy centers), mainly in the calibration of c linical dosemeters . In 1976 the International Atomic Energy Agency, (IAEA), and the World Health Organization, (WHO), they carried out a mutual agreement with regard to the establishment and operation of a net of Secondary Patron Laboratories of Dosimetry, (LSCD). The necessity to establish measure patterns in the field of the dosimetry of the ionizing radiations, is necessary, to have an accuracy but high in the dosimetry of the radiation beams in therapy which is highly dependent of the dose given to the tumor of those patient with cancer. Similar levels of accuracy are required in protection measures to the radiation with an acceptable smaller accuracy, however, when the personal dosemeters are used to determine the doses received by the individuals under work conditions, such mensurations in therapy of radiations and radiological protection will have traceability through a chain of comparisons to primary or national patterns. The traceability is necessary to assure the accuracy and acceptability of the dosimetric measures, as well as, the legal and economic implications. The traceability is also necessary in the dosimetry of high dose like in the sterilization of different products. The main function of the LSCD is to provide a service in metrology of ionizing radiations, maintaining the secondary or national patterns, which have a traceability to the International System of measures, which is based for if same in the comparison of patterns in the Primary Laboratories of Dosimetry (LPD) under the auspice of the International Office of Weights and Measure (BIPM). The secondary and national patterns in the LSCD constitute in Mexico, the national patterns of the magnitudes in the dosimetry of the

  3. Dependence of Achievable Plan Quality on Treatment Technique and Planning Goal Refinement: A Head-and-Neck Intensity Modulated Radiation Therapy Application

    International Nuclear Information System (INIS)

    Qi, X. Sharon; Ruan, Dan; Lee, Steve P.; Pham, Andrew; Kupelian, Patrick; Low, Daniel A.; Steinberg, Michael; Demarco, John

    2015-01-01

    Purpose: To develop a practical workflow for retrospectively analyzing target and normal tissue dose–volume endpoints for various intensity modulated radiation therapy (IMRT) delivery techniques; to develop technique-specific planning goals to improve plan consistency and quality when feasible. Methods and Materials: A total of 165 consecutive head-and-neck patients from our patient registry were selected and retrospectively analyzed. All IMRT plans were generated using the same dose–volume guidelines for TomoTherapy (Tomo, Accuray), TrueBeam (TB, Varian) using fixed-field IMRT (TB-IMRT) or RAPIDARC (TB-RAPIDARC), or Siemens Oncor (Siemens-IMRT, Siemens). A MATLAB-based dose–volume extraction and analysis tool was developed to export dosimetric endpoints for each patient. With a fair stratification of patient cohort, the variation of achieved dosimetric endpoints was analyzed among different treatment techniques. Upon identification of statistically significant variations, technique-specific planning goals were derived from dynamically accumulated institutional data. Results: Retrospective analysis showed that although all techniques yielded comparable target coverage, the doses to the critical structures differed. The maximum cord doses were 34.1 ± 2.6, 42.7 ± 2.1, 43.3 ± 2.0, and 45.1 ± 1.6 Gy for Tomo, TB-IMRT, TB-RAPIDARC, and Siemens-IMRT plans, respectively. Analyses of variance showed significant differences for the maximum cord doses but no significant differences for other selected structures among the investigated IMRT delivery techniques. Subsequently, a refined technique-specific dose–volume guideline for maximum cord dose was derived at a confidence level of 95%. The dosimetric plans that failed the refined technique-specific planning goals were reoptimized according to the refined constraints. We observed better cord sparing with minimal variations for the target coverage and other organ at risk sparing for the Tomo cases, and higher

  4. Verification system development a dosimetric tridimensional using Solution Fricke gel in the application for verification of radiation therapy in arc modulated volumetric (VMAT) in treatment with target moving for breathing

    International Nuclear Information System (INIS)

    Sakuraba, Roberto Kenji

    2015-01-01

    Volumetric Modulated Arc Therapy (VMAT) is one of the methods most commonly used in teletherapy to treat cancer. The various technological advances and the evolution of treatment techniques made the VMAT as one of the state of the art methods for the treatment of some cancers. Part of this improvement is credited to improvements in accuracy and prescription dose absorbed recommended to the patient over the years. This advance allows currently is possible to perform dosimetric calculations by means of the computerized planning system, considering the heterogeneity of patients, such as tissues and organs with different water compositions medium (reference radiation), and individual patient contour the movement of tumors breathing. Such advances require quality control of these tools, in order to ensure that the entire treatment process is satisfactory and accurate. Up to now, the community lacks an experimental system capable of evaluating, considering the uncertainty levels if the computerized planning systems are able to consider the movement of targets in the treatments with VMAT. In this paper, will be presented the results obtained with the phantom Fricke Xylenol Gel, capable of measuring the differences introduced by movement using the Magnetic Resonance Image - MRI and compared qualitatively and quantitatively. The main stages of the phantom development, their experimental results, conclusions and comparisons with other systems are discussed. (author)

  5. Adjuvant radiation therapy for bladder cancer: A dosimetric comparison of techniques

    Energy Technology Data Exchange (ETDEWEB)

    Baumann, Brian C.; Noa, Kate [Department of Radiation Oncology at the University of Pennsylvania, Philadelphia, PA (United States); Wileyto, E. Paul [Department of Biostatistics and Epidemiology at the University of Pennsylvania, Philadelphia, PA (United States); Bekelman, Justin E. [Department of Radiation Oncology at the University of Pennsylvania, Philadelphia, PA (United States); Deville, Curtiland [Department of Radiation Oncology and Molecular Radiation Sciences at Johns Hopkins University School of Medicine, Baltimore, MD (United States); Vapiwala, Neha; Kirk, Maura; Both, Stefan; Dolney, Derek; Kassaee, Ali [Department of Radiation Oncology at the University of Pennsylvania, Philadelphia, PA (United States); Christodouleas, John P., E-mail: christojo@uphs.upenn.edu [Department of Radiation Oncology at the University of Pennsylvania, Philadelphia, PA (United States)

    2015-01-01

    Trials of adjuvant radiation after cystectomy are under development. There are no studies comparing radiation techniques to inform trial design. This study assesses the effect on bowel and rectal dose of 3 different modalities treating 2 proposed alternative clinical target volumes (CTVs). Contours of the bowel, rectum, CTV-pelvic sidewall (common/internal/external iliac and obturator nodes), and CTV-comprehensive (CTV-pelvic sidewall plus cystectomy bed and presacral regions) were drawn on simulation images of 7 post-cystectomy patients. We optimized 3-dimensional conformal radiation (3-D), intensity-modulated radiation (IMRT), and single-field uniform dose (SFUD) scanning proton plans for each CTV. Mixed models regression was used to compare plans for bowel and rectal volumes exposed to 35% (V{sub 35%}), 65% (V{sub 65%}), and 95% (V{sub 95%}) of the prescribed dose. For any given treatment modality, treating the larger CTV-comprehensive volume compared with treating only the CTV-pelvic sidewall nodes significantly increased rectal dose (V{sub 35%} {sub rectum}, V{sub 65%} {sub rectum}, and V{sub 95%} {sub rectum}; p < 0.001 for all comparisons), but it did not produce significant differences in bowel dose (V{sub 95%} {sub bowel}, V{sub 65%} {sub bowel}, or V{sub 35%} {sub bowel}). The 3-D plans, compared with both the IMRT and the SFUD plans, had a significantly greater V{sub 65%} {sub bowel} and V{sub 95%} {sub bowel} for each proposed CTV (p < 0.001 for all comparisons). The effect of treatment modality on rectal dosimetry differed by CTV, but it generally favored the IMRT and the SFUD plans over the 3-D plans. Comparison of the IMRT plan vs the SFUD plan yielded mixed results with no consistent advantage for the SFUD plan over the IMRT plan. Targeting a CTV that spares the cystectomy bed and presacral region may marginally improve rectal toxicity but would not be expected to improve the bowel toxicity associated with any given modality of adjuvant radiation

  6. Dosimetric comparison of different schemes for arrange beams in intensity modulated radiation therapy for mid- and distal-esophageal carcinoma

    International Nuclear Information System (INIS)

    Zhang Min; Zhou Li; Zhang Kaixian; Li Ling; Shi Cun

    2012-01-01

    Objective: To analyze the difference between five-field plan and seven-field plan in intensity modulated radiation therapy for patients with mid- and distal-esophageal carcinoma,and to find out the optimal beam arrangement. Methods: Five-field plan and seven-field plan were designed for each of 12 patients with mid- and distal-esophageal carcinoma. 95% of planning target volume was required to achieve prescription dose. Dose-volume histograms statistics, dose uniformity, and dose conformity in every patient were compared respectively.Results: Superior dose conformity for planning target volume was shown in seven-field plan (t=2.681, P<0.05). Difference was not significant between uniformity in seven-field plan and that in five-field plan. Difference was not significant between doses received by organs at risk,such as spinal cord and heart,in seven-field plan and those in five-field plan. V 5 , V 10 , V 15 of lungs in five-field plan were lower significantly than those in seven-field plan (t=-7.938, -12.055 and -4.859, all P<0.05). Conclusions: For patients with thoracic esophageal carcinoma treated by intensity modulate radiation therapy, compared with 7-fielded plan,the volume of lungs with lower dose could be reduced on the premise of acceptable planning target volume coverage by the application of five-plan. Therefore, radiation-induced lung injury occurrence probability would be reduced, and the patient's quality of life would be improved. Five-field plan would be worth applying in the clinical work. (authors)

  7. DNA repair related to radiation therapy

    International Nuclear Information System (INIS)

    Klein, W.

    1979-01-01

    The DNA excision repair capacity of peripheral human lymphocytes after radiation therapy has been analyzed. Different forms of application of the radiation during the therapy have been taken into account. No inhibition of repair was found if cells were allowed a certain amount of accomodation to radiation, either by using lower doses or longer application times. (G.G.)

  8. Radiation therapy facilities in the United States

    International Nuclear Information System (INIS)

    Ballas, Leslie K.; Elkin, Elena B.; Schrag, Deborah; Minsky, Bruce D.; Bach, Peter B.

    2006-01-01

    Purpose: About half of all cancer patients in the United States receive radiation therapy as a part of their cancer treatment. Little is known, however, about the facilities that currently deliver external beam radiation. Our goal was to construct a comprehensive database of all radiation therapy facilities in the United States that can be used for future health services research in radiation oncology. Methods and Materials: From each state's health department we obtained a list of all facilities that have a linear accelerator or provide radiation therapy. We merged these state lists with information from the American Hospital Association (AHA), as well as 2 organizations that audit the accuracy of radiation machines: the Radiologic Physics Center (RPC) and Radiation Dosimetry Services (RDS). The comprehensive database included all unique facilities listed in 1 or more of the 4 sources. Results: We identified 2,246 radiation therapy facilities operating in the United States as of 2004-2005. Of these, 448 (20%) facilities were identified through state health department records alone and were not listed in any other data source. Conclusions: Determining the location of the 2,246 radiation facilities in the United States is a first step in providing important information to radiation oncologists and policymakers concerned with access to radiation therapy services, the distribution of health care resources, and the quality of cancer care

  9. MOSFET dosimetry on modern radiation oncology modalities

    International Nuclear Information System (INIS)

    Rosenfeld, A.B.

    2002-01-01

    The development of MOSFET dosimetry is presented with an emphasis on the development of a scanning MOSFET dosimetry system for modern radiation oncology modalities. Fundamental aspects of MOSFETs in relation to their use as dosemeters are briefly discussed. The performance of MOSFET dosemeters in conformal radiotherapy, hadron therapy, intensity-modulated radiotherapy and microbeam radiation therapy is compared with other dosimetric techniques. In particular the application of MOSFET dosemeters in the characterisation and quality assurance of the steep dose gradients associated with the penumbra of some modern radiation oncology modalities is investigated. A new in vivo, on-line, scanning MOSFET read out system is also presented. The system has the ability to read out multiple MOSFET dosemeters with excellent spatial resolution and temperature stability and minimal slow border trapping effects. (author)

  10. SU-E-T-25: A Dosimetric Comparison of Three-Dimension Conformal and Intensity-Modulated Radiation Therapy in Esophageal Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Gallardo, N; Maneru, F; Fuentemilla, N; Olasolo, J; Gracia, M; Pellejero, S; Bragado, L; Lozares, S; Miquelez, S; Martin, M [Complejo Hospitalario de Navarra, Pamplona, Navarra (Spain)

    2015-06-15

    Purpose: dosimetric comparison of 3DCRT and IMRT in 9 esophageal cancer. The aim of this paper is to know which of these two techniques is dosimetrically more favorable dosimetrically at both the CTV coverage and dose obtained in the relevant organs at risk, in this case, lungs and heart, as the spinal cord received in all cases below 45 Gy. Methods: we chose 9 patients from our center (CHN) with the same type of esophageal cancer and in which the prescribed dose was the same, 54 Gy. For these treatments we have used the same fields and the same angles (AP (0 °), OPD (225°–240°) and OPI (125°–135°)).All plans have been implemented using Eclipse (version 11.0) with AAA( Analytical Anisotropic Algorithm )(Version 11.0.31). Results: To analyze the coverage of the CTV, we have evaluated the D99% and found that the average dose received by 99% of CTV with IMRT is 53.8 ± 0.4 Gy (99.6% of the prescribed dose) and the mean value obtained with 3DCRT is 52.3 ± 0.6 Gy (96.8% of the prescribed dose).The last data analyzed was the D2% of PTV, a fact that gives us information on the maximum dose received by our PTV. D2% of the PTV for IMRT planning is 55.4 ± 0.4 Gy (102.6% of the prescribed dose) and with 3DCRT is 56.8 ± 0.7 Gy (105.2% of the prescribed dose).All parameters analyzed at risk organs (V30, V40, V45 and V50 for the case of heart and V5, V10, V15 and V20 for the case of the lungs) provide us irradiated volume percentages lower in IMRT than 3DCRT. Conclusion: IMRT provides a considerable improvement in the coverage of the CTV and the doses to organs at risk.

  11. SU-G-TeP2-15: Feasibility Study of Fiber-Optic Cerenkov Radiation Sensors for in Vivo Measurement: Dosimetric Characterization and Clinical Application in Proton Beams

    Energy Technology Data Exchange (ETDEWEB)

    Lah, J [Myongji Hospital, Goyang-si (Korea, Republic of); Son, J [Korea University, Seoul (Korea, Republic of); Kim, G [University of California, San Diego, La Jolla, CA (United States); Shin, D [National Cancer Center, Goyang-si (Korea, Republic of)

    2016-06-15

    Purpose: To evaluate the possibility of a fiber-optic Cerenkov radiation sensor (FCRS) for in vivo dose verification in proton therapy. Methods: The Cerenkov radiation due to the proton beam was measured using a homemade phantom, consisting of a plastic optical fiber (POF, PGSCD1001-13-E, Toray, Tokyo, Japan) connected to each channel of a multianode photomultiplier tube (MAPMT:H7546, Hamamatsu Photonics, Shizuoka, Japan). Data were acquired using a multi-anode photomultiplier tube with the NI-DAQ system (National Instruments Texas, USA). The real-time monitoring graphic user interface was programmed using Labview. The FCRS was analyzed for its dosimetrics characteristic in proton beam. To determine the accuracy of the FCRS in proton dose measurements, we compared the ionization chamber dose measurements using a water phantom. We investigated the feasibility of the FCRS for the measurement of dose distributions near the superficial region for proton plans with a varying separation between the target volume and the surface of 3 patients using a humanoid phantom. Results: The dose-response has good linearity. Dose-rate and energy dependence were found to be within 1%. Depth-dose distributions in non-modulated proton beams obtained with the FCRS was in good agreement with the depth-dose measurements from the ionization chamber. To evaluate the dosimetric accuracy of the FCRS, the difference of isocenter dose between the delivery dose calculated by the treatment planning system and that measured by the FCRS was within 3%. With in vivo dosimetry using the humanoid phantom, the calculated surface doses overestimated measurements by 4%–8% using FCRS. Conclusion: In previous study, our results indicate that the performance of the array-type FCRS was comparable to that of the currently used a multi-layer ion chamber system. In this study, we also believe that the fiber-optic Cerenkov radiation sensor has considerable potential for use with in vivo patient proton dosimetry.

  12. Involved Node Radiation Therapy

    DEFF Research Database (Denmark)

    Maraldo, Maja V; Aznar, Marianne C; Vogelius, Ivan R

    2012-01-01

    PURPOSE: The involved node radiation therapy (INRT) strategy was introduced for patients with Hodgkin lymphoma (HL) to reduce the risk of late effects. With INRT, only the originally involved lymph nodes are irradiated. We present treatment outcome in a retrospective analysis using this strategy...... to 36 Gy). Patients attended regular follow-up visits until 5 years after therapy. RESULTS: The 4-year freedom from disease progression was 96.4% (95% confidence interval: 92.4%-100.4%), median follow-up of 50 months (range: 4-71 months). Three relapses occurred: 2 within the previous radiation field......, and 1 in a previously uninvolved region. The 4-year overall survival was 94% (95% confidence interval: 88.8%-99.1%), median follow-up of 58 months (range: 4-91 months). Early radiation therapy toxicity was limited to grade 1 (23.4%) and grade 2 (13.8%). During follow-up, 8 patients died, none from HL, 7...

  13. Quantitative dosimetric assessment for effect of gold nanoparticles as contrast media on radiotherapy planning

    Science.gov (United States)

    Tu, Shu-Ju; Yang, Pei-Ying; Hong, Ji-Hong; Lo, Ching-Jung

    2013-07-01

    In CT planning for radiation therapy, patients may be asked to have a medical procedure of contrast agent (CA) administration as required by their physicians. CA media improve quality of CT images and assist radiation oncologists in delineation of the target or organs with accuracy. However, dosimetric discrepancy may occur between scenarios in which CA media are present in CT planning and absent in treatment delivery. In recent preclinical experiments of small animals, gold nanoparticles (AuNPs) have been identified as an excellent contrast material of x-ray imaging. In this work, we quantitatively evaluate the effect of AuNPs to be used as a potential material of contrast enhancement in radiotherapy planning with an analytical phantom and clinical case. Conray 60, an iodine-based product for contrast enhancement in clinical uses, is included as a comparison. Other additional variables such as different concentrations of CA media, radiation delivery techniques and dose calculation algorithms are included. We consider 1-field AP, 4-field box, 7-field intensity modulated radiation therapy (IMRT) and a recent technique of volumetric modulated arc therapy (VMAT). CA media of AuNPs (Conray 60) with concentrations of 10%, 20%, 30%, 40% and 50% containing 28.2, 56.4, 84.6, 112.8 and 141.0 mg of gold (iodine) per mL were prepared prior to CT scanning. A virtual phantom with a target where nanoparticle media are loaded and clinical case of gastric lymphoma in which the Conray 60 media were given to the patient prior to the CT planning are included for the study. Compared to Conray 60 media with concentration of 10%/50%, Hounsfield units for AuNP media of 10%/50% are 322/1608 higher due to the fact that atomic number of Au (Z=79) is larger than I (Z=53). In consequence, dosimetric discrepancy of AuNPs is magnified between presence and absence of contrast media. It was found in the phantom study that percent dose differences between presence and absence of CA media may be

  14. Whole-brain hippocampal sparing radiation therapy: Volume-modulated arc therapy vs intensity-modulated radiation therapy case study

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Katrina, E-mail: Trinabena23@gmail.com; Lenards, Nishele; Holson, Janice

    2016-04-01

    The hippocampus is responsible for memory and cognitive function. An ongoing phase II clinical trial suggests that sparing dose to the hippocampus during whole-brain radiation therapy can help preserve a patient's neurocognitive function. Progressive research and advancements in treatment techniques have made treatment planning more sophisticated but beneficial for patients undergoing treatment. The aim of this study is to evaluate and compare hippocampal sparing whole-brain (HS-WB) radiation therapy treatment planning techniques using volume-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT). We randomly selected 3 patients to compare different treatment techniques that could be used for reducing dose to the hippocampal region. We created 2 treatment plans, a VMAT and an IMRT, from each patient's data set and planned on the Eclipse 11.0 treatment planning system (TPS). A total of 6 plans (3 IMRT and 3 VMAT) were created and evaluated for this case study. The physician contoured the hippocampus as per the Radiation Therapy Oncology Group (RTOG) 0933 protocol atlas. The organs at risk (OR) were contoured and evaluated for the plan comparison, which included the spinal cord, optic chiasm, the right and left eyes, lenses, and optic nerves. Both treatment plans produced adequate coverage on the planning target volume (PTV) while significantly reducing dose to the hippocampal region. The VMAT treatment plans produced a more homogenous dose distribution throughout the PTV while decreasing the maximum point dose to the target. However, both treatment techniques demonstrated hippocampal sparing when irradiating the whole brain.

  15. Whole-brain hippocampal sparing radiation therapy: Volume-modulated arc therapy vs intensity-modulated radiation therapy case study

    International Nuclear Information System (INIS)

    Lee, Katrina; Lenards, Nishele; Holson, Janice

    2016-01-01

    The hippocampus is responsible for memory and cognitive function. An ongoing phase II clinical trial suggests that sparing dose to the hippocampus during whole-brain radiation therapy can help preserve a patient's neurocognitive function. Progressive research and advancements in treatment techniques have made treatment planning more sophisticated but beneficial for patients undergoing treatment. The aim of this study is to evaluate and compare hippocampal sparing whole-brain (HS-WB) radiation therapy treatment planning techniques using volume-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT). We randomly selected 3 patients to compare different treatment techniques that could be used for reducing dose to the hippocampal region. We created 2 treatment plans, a VMAT and an IMRT, from each patient's data set and planned on the Eclipse 11.0 treatment planning system (TPS). A total of 6 plans (3 IMRT and 3 VMAT) were created and evaluated for this case study. The physician contoured the hippocampus as per the Radiation Therapy Oncology Group (RTOG) 0933 protocol atlas. The organs at risk (OR) were contoured and evaluated for the plan comparison, which included the spinal cord, optic chiasm, the right and left eyes, lenses, and optic nerves. Both treatment plans produced adequate coverage on the planning target volume (PTV) while significantly reducing dose to the hippocampal region. The VMAT treatment plans produced a more homogenous dose distribution throughout the PTV while decreasing the maximum point dose to the target. However, both treatment techniques demonstrated hippocampal sparing when irradiating the whole brain.

  16. SU-E-T-589: Optimization of Patient Head Angle Position to Spare Hippocampus During the Brain Radiation Therapy

    International Nuclear Information System (INIS)

    Cheon, G; Kang, Y; Kang, S; Kim, T; Kim, D; Suh, T

    2015-01-01

    Purpose: Hippocampus is one of the important organs which controls emotions, behaviors, movements the memorizing and learning ability. In the conventional head & neck therapy position, it is difficult to perform the hippocampal-sparing brain radiation therapy. The purpose of this study is to investigate optimal head angle which can save the hippocampal-sparing and organ at risk (OAR) in conformal radiation therapy (CRT), Intensity modulation radiation therapy (IMRT) and helical tomotherapy (HT). Methods: Three types of radiation treatment plans, CRT, IMRT and Tomotherapy plans, were performed for 10 brain tumor patients. The image fusion between CT and MRI data were used in the contour due to the limited delineation of the target and OAR in the CT scan. The optimal condition plan was determined by comparing the dosimetric performance of the each plan with the use of various parameters which include three different techniques (CRT, IMRT, HT) and 4 angle (0, 15, 30, 40 degree). The each treatment plans of three different techniques were compared with the following parameters: conformity index (CI), homogeneity index (HI), target coverage, dose in the OARs, monitor units (MU), beam on time and the normal tissue complication probability (NTCP). Results: HI, CI and target coverage was most excellent in head angle 30 degree among all angle. When compared by modality, target coverage and CI showed good results in IMRT and TOMO than compared to the CRT. HI at the head angle 0 degrees is 1.137±0.17 (CRT), 1.085±0.09 (IMRT) and 1.077±0.06 (HT). HI at the head angle 30 degrees is 1.056±0.08 (CRT), 1.020±0.05 (IMRT) and 1.022±0.07 (HT). Conclusion: The results of our study show that when head angle tilted at 30 degree, target coverage, HI, CI were improved, and the dose delivered to OAR was reduced compared with conventional supine position in brain radiation therapy. This work was supported by the Radiation Technology R&D program (No. 2013M2A2A7043498) and the Mid

  17. SU-E-T-589: Optimization of Patient Head Angle Position to Spare Hippocampus During the Brain Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Cheon, G; Kang, Y [Radiation Oncology, Seoul St. Mary’s Hospital, Seoul (Korea, Republic of); Kang, S; Kim, T; Kim, D; Suh, T [The Catholic University of Korea, Seoul (Korea, Republic of)

    2015-06-15

    Purpose: Hippocampus is one of the important organs which controls emotions, behaviors, movements the memorizing and learning ability. In the conventional head & neck therapy position, it is difficult to perform the hippocampal-sparing brain radiation therapy. The purpose of this study is to investigate optimal head angle which can save the hippocampal-sparing and organ at risk (OAR) in conformal radiation therapy (CRT), Intensity modulation radiation therapy (IMRT) and helical tomotherapy (HT). Methods: Three types of radiation treatment plans, CRT, IMRT and Tomotherapy plans, were performed for 10 brain tumor patients. The image fusion between CT and MRI data were used in the contour due to the limited delineation of the target and OAR in the CT scan. The optimal condition plan was determined by comparing the dosimetric performance of the each plan with the use of various parameters which include three different techniques (CRT, IMRT, HT) and 4 angle (0, 15, 30, 40 degree). The each treatment plans of three different techniques were compared with the following parameters: conformity index (CI), homogeneity index (HI), target coverage, dose in the OARs, monitor units (MU), beam on time and the normal tissue complication probability (NTCP). Results: HI, CI and target coverage was most excellent in head angle 30 degree among all angle. When compared by modality, target coverage and CI showed good results in IMRT and TOMO than compared to the CRT. HI at the head angle 0 degrees is 1.137±0.17 (CRT), 1.085±0.09 (IMRT) and 1.077±0.06 (HT). HI at the head angle 30 degrees is 1.056±0.08 (CRT), 1.020±0.05 (IMRT) and 1.022±0.07 (HT). Conclusion: The results of our study show that when head angle tilted at 30 degree, target coverage, HI, CI were improved, and the dose delivered to OAR was reduced compared with conventional supine position in brain radiation therapy. This work was supported by the Radiation Technology R&D program (No. 2013M2A2A7043498) and the Mid

  18. Influence of lucite phantoms on calibration of dosimetric pens

    International Nuclear Information System (INIS)

    Oliveira, E.C.; Xavier, M.; Caldas, L.E.V.

    1992-01-01

    Dosimetrical pens were studied for the answer repetition and were tested in gamma radiation fields ( 60 Co and 137 Cs) in air and in front of a lucite phantom, obtaining a backscattering contribution. The medium backscattering factors were 1,053 and 1,108 for respectively 60 Co and 137 Cs. The pens were placed behind the phantom for verifying the radiation attenuation. (C.G.C.)

  19. Bremsstrahlung parameters of praseodymium-142 in different human tissues. A dosimetric perspective for 142Pr radionuclide therapy

    International Nuclear Information System (INIS)

    Bakht, M.K.; Jabal-Ameli, H.; Ahmadi, S.J.; Sadeghi, M.; Sadjadi, S.; Tenreiro, Claudio

    2012-01-01

    Praseodymium-142 [T 1/2 =19.12 h, E β -=2.162 MeV (96.3%), E γ =1575 keV (3.7%)] is one of the 141 Pr radioisotopes. Many studies have been attempted to assess the significance of usage 142 Pr in radionuclide therapy. In many studies, the dosimetric parameters of 142 Pr sources were calculated by modeling 142 Pr sources in the water phantom and scoring the energy deposited around it. However, the medical dosimetry calculations in water phantom consider Bremsstrahlung production, raising the question: ''How important is to simulate human tissues instead of using water phantom?'' This study answers these questions by estimation of 142 Pr Bremsstrahlung parameters. The Bremsstrahlung parameters of 142 Pr as therapeutic beta nuclides in different human tissues (adipose, blood, brain, breast, cell nucleus, eye lens, gastrointestinal tract, heart, kidney, liver, lung deflated, lymph, muscle, ovary, pancreas, cartilage, red marrow, spongiosa, yellow marrow, skin, spleen, testis, thyroid and different skeleton bones) were calculated by extending the national council for radiation protection model. The specific Bremsstrahlung constant (Γ Br ), probability of energy loss by beta during Bremsstrahlung emission (P Br ) and Bremsstrahlung activity (A release ) Br were estimated. It should be mentioned that Monte Carlo simulation was used for estimation of 142 Pr Bremsstrahlung activity based on the element compositions of different human tissues and the calculated exposures from the anthropomorphic phantoms. Γ Br for yellow marrow was smallest amount (1.1962 x 10 -3 C/kg-cm 2 /MBq-h) compared to the other tissues and highest for cortical bone (2.4764 x 10 -3 C/kg-cm 2 /MBq-h), and, overall, Γ Br for skeletal tissues were greater than other tissues. In addition, Γ Br breast was 1.8261 x 10 -3 C/kg-cm 2 /MBq-h which was greater than sacrum and spongiosa bones. Moreover, according to (A release ) Br of 142 Pr, the patients receiving 142 Pr do not have to be hospitalized for

  20. External radiation therapy of prostatic carcinoma and its relationship to hormonal therapy

    International Nuclear Information System (INIS)

    Takada, Chitose; Ito, Koushiro; Nishi, Junko; Yamamoto, Toshihiro; Hatanaka, Yoshimi; Baba, Yuji; Takahashi, Mutsumasa.

    1995-01-01

    From 1980 to 1990, a total of 54 patients with prostatic carcinoma were treated with external radiation therapy at the Kumamoto National Hospital. Ten patients were classified as Stage B, 22 as Stage C, and another 22 as Stage D according to the American Urological Association Clinical Staging System. The 5-year survival for all 54 patients was 30%. The 5-year disease-specific survival was 67% for Stage B, 47% for Stage C, and 26% for Stage D. The 5-year survival was 43% for patients in whom radiation therapy was initiated immediately after the first diagnosis or with less than one year of hormonal therapy, while it was 0% for patients in whom radiation therapy was initiated after more than one year of hormonal therapy (p=0.01). The cause of intercurrent death was acute myocardial infarction in four patients and acute cardiac failure in one. Four of these patients received hormonal therapy for more than one year. The incidence of radiation-induced proctitis was not severe. This study suggests that long-term hormonal therapy prior to radiation therapy worsens the prognosis of patients with prostatic carcinoma. (author)

  1. Therapy with {sup 90}Y microspheres: radiation protection in new medical therapies; Terapia con microesferas de {sup 90}Y: proteccion radiologica en nuevas terapias medicas

    Energy Technology Data Exchange (ETDEWEB)

    Rojo, Ana; Puerta, Nancy, E-mail: arojo@arn.gob.ar [Autoridad Regulatoria Nuclear (ARN), Buenos Aires (Argentina)

    2013-07-01

    Primary liver cancer is one of the most frequent in the world and with a low cure rate. Radioembolization using 90y spheres is a promising treatment of this pathology and involves the percutaneous vascular application of radioisotope-labeled the order of Micron size particles. The advantages of this technique include the permit administered high doses of radiation to small volumes with low relative toxicity, offer the possibility of treating all the liver including microscopic tumors, and finally, the feasibility of combined with other therapies. Radiation protection in new medical therapies requires justification and optimization, as requirements for their implementation. The application of the principle of optimization in the context of the protection of the patient must be the minimum that it can be reasonably reached compatible with the required doses of treatment dose to healthy tissue. With {sup 90}Y microspheres therapy this optimization applies to the activity of 90y which is administered to the patient, and estimation methods are postulated. in this work are analyzed comparatively these methods, described the early physicists, equations and the limitations of each. Finally, it is concluded that the optimal method to be implemented for the evaluation of the activity of {sup 90}Y manage must be based in a voxel dosimetric model specific for each patient, however, the partitional method may be a good alternative if you don't have the tools to apply the method.

  2. Dose impact of a carbon fiber couch for stereotactic body radiation therapy of lung tumors

    International Nuclear Information System (INIS)

    Tominaga, Hirofumi; Kanetake, Nagisa; Kawasaki, Keiichi; Iwashita, Yuki; Sakata, Junichi; Okuda, Tomoko; Araki, Fujio; Shimohigashi, Yoshinobu; Tomiyama, Yuki

    2013-01-01

    The aim of this study was to measure the dose attenuation caused by a carbon fiber radiation therapy table (Imaging Couch Top; ICT, BrainLab) and to evaluate the dosimetric impact of ICT during stereotactic body radiation therapy (SBRT) in lung tumors. The dose attenuation of ICT was measured using an ionization chamber and modeled by means of a treatment planning system (TPS). SBRT was planned with and without ICT in a lung tumor phantom and ten cases of clinical lung tumors. The results were analyzed from isocenter doses and a dose-volume histogram (DVH): D 95 , D mean , V 20 , V 5 , homogeneity index (HI), and conformity index (CI). The dose attenuation of the ICT modeled with TPS agreed to within ±1% of the actually measured values. The isocenter doses, D 95 and D mean with and without ICT showed differences of 4.1-5% for posterior single field and three fields in the phantom study, and differences of 0.6-2.4% for five fields and rotation in the phantom study and six fields in ten clinical cases. The dose impact of ICT was not significant for five or more fields in SBRT. It is thus possible to reduce the dose effect of ICT by modifying the beam angle and beam weight in the treatment plan. (author)

  3. Intensity-modulated radiation therapy: not a dry eye in the house

    International Nuclear Information System (INIS)

    Arnold, Anthony; Arnold, Belinda; Capp, Anne; Fox, Chris; Metcalfe, Peter; Chapman, Alison; Tangboonduangjit, Puangpeng

    2004-01-01

    Inverse planned intensity-modulated radiation therapy (IMRT) has been applied to patients in a conformal fashion in order to avoid the lacrimal gland. In the present study, we report a patient in which a potential planned dose of 63 Gy to the lacrimal gland for a conventional plan was reduced to 12 Gy to the lacrimal gland for the IMRT plan. Dose objective inverse planning was provided using a Pinnacle treatment planning computer and treatment was delivered using a Varian dynamic multileaf collimator (MLC) on a Varian linear accelerator. Because multiple MLC segments are used to deliver the modulated treatment, conventional dose checks by manual calculation are not practical. To aid in an alternative dosimetric verification process, the Pinnacle planning computer has two unique dose tools, which provide axial and beams eye view doses on user-specified check phantoms. The combined field axial dose tool matched our ion chamber dose checks within ± 2.4% at the isocentre. The individual beams eye view dose tool matched film dose maps within ± 3% in the umbra Copyright (2004) Blackwell Publishing Asia Pty Ltd

  4. Dosimetric characteristics of radiation fields on board Czechoslovak Airlines' aircraft as measured with different active and passive detectors

    International Nuclear Information System (INIS)

    Spurney, F.; Obraz, O.; Pernicka, F.; Votockova, I.; Turek, K.; Vojtisek, O.; Starostova, V.

    1993-01-01

    Dosimetric characteristics on board Czechoslovak Airlines' aircraft (TU 154M; A310-300) were studied with different active and passive detectors (ionisation chamber RSS 112; scintillator based rate meter; GM counter based rate meter; neutron remmeter based on neutron moderation; thermoluminescence detectors, CR 39 track detectors and bubble-damage neutron detectors). Results obtained are analysed and discussed. It is estimated that the dose equivalent rates at altitudes of about 10 km are at least 3-4 μSv.h-1. Conclusions and recommendations for further studies and for radiation protection are given. (author)

  5. Communication skills training for radiation therapists: preparing patients for radiation therapy.

    Science.gov (United States)

    Halkett, Georgia; O'Connor, Moira; Aranda, Sanchia; Jefford, Michael; Merchant, Susan; York, Debra; Miller, Lisa; Schofield, Penelope

    2016-12-01

    Patients sometimes present for radiation therapy with high levels of anxiety. Communication skills training may assist radiation therapists to conduct more effective consultations with patients prior to treatment planning and treatment commencement. The overall aim of our research is to examine the effectiveness of a preparatory programme 'RT Prepare' delivered by radiation therapists to reduce patient psychological distress. The purpose of this manuscript was to describe the communication skills workshops developed for radiation therapists and evaluate participants' feedback. Radiation therapists were invited to participate in two communication skills workshops run on the same day: (1) Consultation skills in radiation therapy and (2) Eliciting and responding to patients' emotional cues. Evaluation forms were completed. Radiation therapists' consultations with patients were then audio-recorded and evaluated prior to providing a follow-up workshop with participants. Nine full day workshops were held. Sixty radiation therapists participated. Positive feedback was received for both workshops with 88% or more participants agreeing or strongly agreeing with all the statements about the different components of the two workshops. Radiation therapists highlighted participating in role play with an actor, discussing issues; receiving feedback; acquiring new skills and knowledge; watching others role play and practicing with checklist were their favourite aspects of the initial workshop. The follow-up workshops provided radiation therapists with feedback on how they identified and addressed patients' psychological concerns; time spent with patients during consultations and the importance of finding private space for consultations. Communication skills training consisting of preparing patients for radiation therapy and eliciting and responding to emotional cues with follow-up workshops has the potential to improve radiation therapists' interactions with patients undergoing

  6. Simple Factors Associated With Radiation-Induced Lung Toxicity After Stereotactic Body Radiation Therapy of the Thorax: A Pooled Analysis of 88 Studies

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Jing [Department of Radiation Oncology, GRU Cancer Center/Medical College of Georgia, Georgia Regents University, Augusta, Georgia (United States); Department of Oncology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan (China); Yorke, Ellen D. [Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York (United States); Li, Ling [Department of Radiation Oncology, GRU Cancer Center/Medical College of Georgia, Georgia Regents University, Augusta, Georgia (United States); Department of Shanghai Cancer Hospital, Fudan University, Shanghai (China); Kavanagh, Brian D. [Department of Radiation Oncology, University of Colorado, Denver, Colorado (United States); Li, X. Allen [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin (United States); Das, Shiva [Department of Radiation Oncology, University of North Carolina, Chapel Hill, North Carolina (United States); Miften, Moyed [Department of Radiation Oncology, University of Colorado, Denver, Colorado (United States); Rimner, Andreas [Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York City, New York (United States); Campbell, Jeffrey [Department of Radiation Oncology, GRU Cancer Center/Medical College of Georgia, Georgia Regents University, Augusta, Georgia (United States); Xue, Jinyu [Department of Radiation Oncology, MD Anderson Cancer Center at Cooper, Camden, New Jersey (United States); Jackson, Andrew [Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York (United States); Grimm, Jimm [Bott Cancer Center, Holy Redeemer Hospital, Meadowbrook, Pennsylvania (United States); Milano, Michael T. [Department of Radiation Oncology, University of Rochester, Rochester, New York (United States); and others

    2016-08-01

    Purpose: To study the risk factors for radiation-induced lung toxicity (RILT) after stereotactic body radiation therapy (SBRT) of the thorax. Methods and Materials: Published studies on lung toxicity in patients with early-stage non–small cell lung cancer (NSCLC) or metastatic lung tumors treated with SBRT were pooled and analyzed. The primary endpoint was RILT, including pneumonitis and fibrosis. Data of RILT and risk factors were extracted from each study, and rates of grade 2 to 5 (G2+) and grade 3 to 5 (G3+) RILT were computed. Patient, tumor, and dosimetric factors were analyzed for their correlation with RILT. Results: Eighty-eight studies (7752 patients) that reported RILT incidence were eligible. The pooled rates of G2+ and G3+ RILT from all 88 studies were 9.1% (95% confidence interval [CI]: 7.15-11.4) and 1.8% (95% CI: 1.3-2.5), respectively. The median of median tumor sizes was 2.3 (range, 1.4-4.1) cm. Among the factors analyzed, older patient age (P=.044) and larger tumor size (the greatest diameter) were significantly correlated with higher rates of G2+ (P=.049) and G3+ RILT (P=.001). Patients with stage IA versus stage IB NSCLC had significantly lower risks of G2+ RILT (8.3% vs 17.1%, odds ratio = 0.43, 95% CI: 0.29-0.64, P<.0001). Among studies that provided detailed dosimetric data, the pooled analysis demonstrated a significantly higher mean lung dose (MLD) (P=.027) and V20 (P=.019) in patients with G2+ RILT than in those with grade 0 to 1 RILT. Conclusions: The overall rate of RILT is relatively low after thoracic SBRT. Older age and larger tumor size are significant adverse risk factors for RILT. Lung dosimetry, specifically lung V20 and MLD, also significantly affect RILT risk.

  7. New modalities in radiation therapy for treatment of cancer

    International Nuclear Information System (INIS)

    Kumar, Deepak

    2013-01-01

    Cancer is a generic term for a large group of diseases characterized by rapid creation of abnormal cells that grow beyond their usual boundaries, and which can then invade adjoining parts of the body and spread to other organs. Cancer mortality is the second and most common cause of death in the USA and in most European countries. In India, it is the fourth leading disease and the major cause of death. Cancer remains one of the most dreadful disease and approximately ten million cases of cancer occur in the world every year. The course of cancer treatment depends on the type of cancer, its location, and its state of advancement. Cancer is treated with surgery, chemotherapy, radiation therapy, hormone therapy, biological therapy and targeted therapy. Radiation therapy is an important an affordable modality for cancer treatment with minimal side effects. Radiation kills cancer cells with high-energy rays targeted directly to the tumor. Radiation therapy works by damaging the DNA and preventing its replication: therefore, it preferentially kills cancer cells, which rapidly divides. Radiation therapy is used for cure, control, and palliation of cancers in more than 60% of cancer patients. The goal of radiotherapy is to treat the cancer and spare the normal tissue as much as possible. Advances have been made in radiotherapy that allow delivery of higher doses of radiation to the tumor while sparing a greater amount of surrounding tissue, thus achieving more cures and fewer acute and long-term side effects. Technological advances and research are being continued to result in improvements in the field. Several new devices and techniques are used these days in radiotherapy for accurate treatment of cancer. Teletherapy (external radiation therapy) used focused radiation beams targeting well defined tumor through extremely detailed imaging scans. Conventional external beam radiation therapy (2DXRT) is delivered via two-dimensional beams using linear accelerator machines (X

  8. Music therapy CD creation for initial pediatric radiation therapy: a mixed methods analysis.

    Science.gov (United States)

    Barry, Philippa; O'Callaghan, Clare; Wheeler, Greg; Grocke, Denise

    2010-01-01

    A mixed methods research design was used to investigate the effects of a music therapy CD (MTCD) creation intervention on pediatric oncology patients' distress and coping during their first radiation therapy treatment. The music therapy method involved children creating a music CD using interactive computer-based music software, which was "remixed" by the music therapist-researcher to extend the musical material. Eleven pediatric radiation therapy outpatients aged 6 to 13 years were randomly assigned to either an experimental group, in which they could create a music CD prior to their initial treatment to listen to during radiation therapy, or to a standard care group. Quantitative and qualitative analyses generated multiple perceptions from the pediatric patients, parents, radiation therapy staff, and music therapist-researcher. Ratings of distress during initial radiation therapy treatment were low for all children. The comparison between the two groups found that 67% of the children in the standard care group used social withdrawal as a coping strategy, compared to 0% of the children in the music therapy group; this trend approached significance (p = 0.076). MTCD creation was a fun, engaging, and developmentally appropriate intervention for pediatric patients, which offered a positive experience and aided their use of effective coping strategies to meet the demands of their initial radiation therapy treatment.

  9. About the contribution of occupational health's services for risk factors evaluation, medical and dosimetric follow-up in the workers monitoring exposed to ionising radiations in France

    International Nuclear Information System (INIS)

    Bailloeuil, C.; Gonin, M.; Gerondal, M.

    2006-01-01

    Full text of publication follows: French national regulation (31/03/2003) indicates principles of a global approach about the medical and dosimetric follow-up in the workers monitoring. Legislator insists on risks and expositions trace ability along all professional career and after. The aim of this French specific system is to institute medical clinic aspects in accordance with dosimetry and professional risks. The occupational practitioners are approved practitioners who have followed a specific training. The organisation guarantees that a worker will be followed by one specific practitioner in order to reinforce the quality and the traceability of follow up. Medical supervision is done at taking on and at least once a year. It means to identify and take care of risks and expositions at work stations. If necessary, biological measurements and recommendations about collective and individual protection equipments complete the estimation of risks. On the subject of emergency, first aid is delivered on sites by occupational health personnel, either for classic medical problem or for radiological accident. Furthermore, occupational health personnel assist outside emergency services with whom we have specific conventions. External dosimetric follow-up is done with radiation protection qualified expert of the company. The internal contamination supervision and internal dose evaluation are done by the occupational health services. Measurements either whole body counts or radio-toxicologic analysis are submitted to technical quality process. Beyond the respect of regulatory dose limits, the aim of the dosimetric follow-up is the contribution to the preparation of work places with strong dosimetric focus. Informations at workers are dispensed about every risks and every kinds of risks: ionising radiation health effects, ionising radiation and pregnancy, high exposition, chemical risks, work at heat, asbestos. All data are conserved 50 years after the exposure These data

  10. SU-F-T-539: Dosimetric Comparison of Volumetric Modulated Arc Therapy and Intensity Modulated Radiation Therapy for Whole Brain Hippocampal Sparing Radiation Therapy Treatments

    Energy Technology Data Exchange (ETDEWEB)

    Kendall, E; Higby, C; Algan, O; Ahmad, S; Hossain, S [University of Oklahoma Health Sciences Center, Oklahoma City, OK (United States)

    2016-06-15

    Purpose: To compare the treatment plan quality and dose gradient near the hippocampus between VMAT (RapidArc) and IMRT delivery techniques for whole brain radiation therapy. Methods: Fifteen patients were evaluated in this retrospective study. All treatments were planned on Varian Eclipse TPS, using 3-Arc VMAT and 9-Field IMRT, following NRG Oncology protocol NRG-CC001 guidelines evaluated by a single radiation oncologist. Prescribed doses in all plans were 30 Gy delivered over 10 fractions normalized to a minimum of 100% of the dose covering 95% of the target volume. Identical contour sets and dose-volume constraints following protocol guidelines were also applied in all plans. A paired t-test analysis was used to compare VMAT and IMRT plans. Results: NRG-CC001 protocol dose-volume constraints were met for all VMAT and IMRT plans. For the planning target volume (PTV), the average values for D2% and D98% were 6% lower and 4% higher in VMAT than in IMRT, respectively. The average mean and maximum hippocampus doses in Gy for VMAT vs IMRT plans were (11.85±0.81 vs. 12.24±0.56, p=0.10) and (16.27±0.78 vs. 16.59±0.71, p=0.24), respectively. In VMAT, the average mean and maximum chiasm doses were 3% and 1% higher than in IMRT plans, respectively. For the left optic nerve, the average mean and maximum doses were 10% and 5% higher in VMAT than in IMRT plans, respectively. These values were 12% and 3% for the right optic nerve. The average percentage of dose gradient around the hippocampus in the 0–5mm and 5–10mm abutted regions for VMAT vs. IMRT were (4.42%±2.22% /mm vs. 3.95%±2.61% /mm, p=0.43) and (4.54%±1.50% /mm vs. 4.39%±1.28% /mm, p=0.73), respectively. Conclusion: VMAT plans can achieve higher hippocampus sparing with a faster dose fall-off than IMRT plans. Though statistically insignificant, VMAT offers better PTV coverage with slightly higher doses to OARs.

  11. SU-F-T-539: Dosimetric Comparison of Volumetric Modulated Arc Therapy and Intensity Modulated Radiation Therapy for Whole Brain Hippocampal Sparing Radiation Therapy Treatments

    International Nuclear Information System (INIS)

    Kendall, E; Higby, C; Algan, O; Ahmad, S; Hossain, S

    2016-01-01

    Purpose: To compare the treatment plan quality and dose gradient near the hippocampus between VMAT (RapidArc) and IMRT delivery techniques for whole brain radiation therapy. Methods: Fifteen patients were evaluated in this retrospective study. All treatments were planned on Varian Eclipse TPS, using 3-Arc VMAT and 9-Field IMRT, following NRG Oncology protocol NRG-CC001 guidelines evaluated by a single radiation oncologist. Prescribed doses in all plans were 30 Gy delivered over 10 fractions normalized to a minimum of 100% of the dose covering 95% of the target volume. Identical contour sets and dose-volume constraints following protocol guidelines were also applied in all plans. A paired t-test analysis was used to compare VMAT and IMRT plans. Results: NRG-CC001 protocol dose-volume constraints were met for all VMAT and IMRT plans. For the planning target volume (PTV), the average values for D2% and D98% were 6% lower and 4% higher in VMAT than in IMRT, respectively. The average mean and maximum hippocampus doses in Gy for VMAT vs IMRT plans were (11.85±0.81 vs. 12.24±0.56, p=0.10) and (16.27±0.78 vs. 16.59±0.71, p=0.24), respectively. In VMAT, the average mean and maximum chiasm doses were 3% and 1% higher than in IMRT plans, respectively. For the left optic nerve, the average mean and maximum doses were 10% and 5% higher in VMAT than in IMRT plans, respectively. These values were 12% and 3% for the right optic nerve. The average percentage of dose gradient around the hippocampus in the 0–5mm and 5–10mm abutted regions for VMAT vs. IMRT were (4.42%±2.22% /mm vs. 3.95%±2.61% /mm, p=0.43) and (4.54%±1.50% /mm vs. 4.39%±1.28% /mm, p=0.73), respectively. Conclusion: VMAT plans can achieve higher hippocampus sparing with a faster dose fall-off than IMRT plans. Though statistically insignificant, VMAT offers better PTV coverage with slightly higher doses to OARs.

  12. First approval procedure of the TL dosimetric service of the NPP in Slovenia

    International Nuclear Information System (INIS)

    Janzekovic, H.; Krizman, M.; Pucelj, B.; Stuhec, M.; Zdesar, U.

    2001-01-01

    The individual dosimetry of exposed workers in a NPP is one of the essential parts which demonstrates the radiation protection standards achieved in a facility. According to the current legislation the Ministry of Health of the Republic of Slovenia has the authority to grant approvals to personal dosimetric services which perform the dosimetric monitoring of workers in Slovenia. Due to the fact that the detailed approval procedure is not given in national regulations, the Ministry of Health in 2000 established a group of experts with the task to prepare technical and organising requirements for such approval. Based on international documents [1,2,3] the Approval procedure for the thermoluminescence dosimetric (TL) services was created. Following this procedure the assessment of the TL dosimetric service in the NPP was performed. The problems related to the technical and organising requirements with the emphasise on the QA/QC criteria of the TL dosimetric service will be discussed.(author)

  13. Pediatric radiation therapy. A Japanese nationwide survey

    International Nuclear Information System (INIS)

    Nemoto, Kenji; Nagata, Yasushi; Hirokawa, Yutaka

    2006-01-01

    A national survey on the current status of pediatric radiation therapy was performed in October 2004. We sent questionnaires to 638 radiotherapy facilities in Japan (except for Kansai area) and 245 responses were analyzed. According to the database of committee of Japanese Society of Therapeutic Radiology and Oncology (JASTRO), the number of pediatric patients who received radiation therapy during 2003 in Japan was 1,101. The most frequent pediatric malignancy was brain tumor, followed by leukemia and lymphoma. The total effort of radiation therapy for children was two to six times larger than that for adult patients. An additional fee seems to be necessary for the highly technical and laborious radiation therapy required for children. (author)

  14. Dosimetric properties of a radiochromic gel detector for diagnostic X-rays

    International Nuclear Information System (INIS)

    Bero, M.A.

    2007-01-01

    The gel dosimetry method was found to be capable of addressing complicated issues related to dose measurements particularly in modern sophisticated radiotherapy applications. The Ferrous-sulphate Xylenol-orange and Gelatin (FXG) radiochromic gel dosemeter is one of the systems used for such applications. Some chemical dosemeters show different responses for low- and medium-energy X-rays in comparison with high-energy γ-photons. The energy and dose rate dependence of the FXG dose response was examined. In addition to the detector response, other important dosimetric properties of the system were investigated for different X-ray beam qualities with tube voltages in the range 100-300 kV. An orthovoltage X-ray therapy unit was used to irradiate standard sized samples of FXG from different batches for radiation doses in the range 0-20 Gy

  15. Development of a personalized dosimetric tool for radiation protection in case of internal contamination and targeted radiotherapy in nuclear medicine

    International Nuclear Information System (INIS)

    Chiavassa, S.

    2005-12-01

    Current internal dosimetric estimations are based on the M.I.R.D. formalism and used standard mathematical models. These standard models are often far from a given patient morphology and do not allow to perform patient-specific dosimetry. The aim of this study was to develop a personalized dosimetric tool, which takes into account real patient morphology, composition and densities. This tool, called O.E.D.I.P.E., a French acronym of Tool for the Evaluation of Personalized Internal Dose, is a user-friendly graphical interface. O.E.D.I.P.E. allows to create voxel-based patient-specific geometries and associates them with the M.C.N.P.X. Monte Carlo code. Radionuclide distribution and absorbed dose calculation can be performed at the organ and voxel scale. O.E.D.I.P.E. can be used in nuclear medicine for targeted radiotherapy and in radiation protection in case of internal contamination. (author)

  16. Whole-brain hippocampal sparing radiation therapy: Volume-modulated arc therapy vs intensity-modulated radiation therapy case study.

    Science.gov (United States)

    Lee, Katrina; Lenards, Nishele; Holson, Janice

    2016-01-01

    The hippocampus is responsible for memory and cognitive function. An ongoing phase II clinical trial suggests that sparing dose to the hippocampus during whole-brain radiation therapy can help preserve a patient׳s neurocognitive function. Progressive research and advancements in treatment techniques have made treatment planning more sophisticated but beneficial for patients undergoing treatment. The aim of this study is to evaluate and compare hippocampal sparing whole-brain (HS-WB) radiation therapy treatment planning techniques using volume-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT). We randomly selected 3 patients to compare different treatment techniques that could be used for reducing dose to the hippocampal region. We created 2 treatment plans, a VMAT and an IMRT, from each patient׳s data set and planned on the Eclipse 11.0 treatment planning system (TPS). A total of 6 plans (3 IMRT and 3 VMAT) were created and evaluated for this case study. The physician contoured the hippocampus as per the Radiation Therapy Oncology Group (RTOG) 0933 protocol atlas. The organs at risk (OR) were contoured and evaluated for the plan comparison, which included the spinal cord, optic chiasm, the right and left eyes, lenses, and optic nerves. Both treatment plans produced adequate coverage on the planning target volume (PTV) while significantly reducing dose to the hippocampal region. The VMAT treatment plans produced a more homogenous dose distribution throughout the PTV while decreasing the maximum point dose to the target. However, both treatment techniques demonstrated hippocampal sparing when irradiating the whole brain. Copyright © 2016 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  17. Dosimetric analysis of BNCT - Boron Neutron Capture Therapy - coupled to 252Cf brachytherapy

    International Nuclear Information System (INIS)

    Brandao, Samia F.; Campos, Tarcisio P.R.

    2009-01-01

    The incidence of brain tumors is increasing in world population; however, the treatments employed in this type of tumor have a high rate of failure and in some cases have been considered palliative, depending on histology and staging of tumor. Its necessary to achieve the control tumor dose without the spread irradiation cause damage in the brain, affecting patient neurological function. Stereotactic radiosurgery is a technique that achieves this; nevertheless, other techniques that can be used on the brain tumor control must be developed, in order to guarantee lower dose on health surroundings tissues other techniques must be developing. The 252 Cf brachytherapy applied to brain tumors has already been suggested, showing promising results in comparison to photon source, since the active source is placed into the tumor, providing greater dose deposition, while more distant regions are spared. BNCT - Boron Neutron Capture Therapy - is another technique that is in developing to brain tumors control, showing theoretical superiority on the rules of conventional treatments, due to a selective irradiation of neoplasics cells, after the patient receives a borate compound infusion and be subjected to a epithermal neutrons beam. This work presents dosimetric studies of the coupling techniques: BNCT with 252 Cf brachytherapy, conducted through computer simulation in MCNP5 code, using a precise and well discretized voxel model of human head, which was incorporated a representative Glioblastoma Multiform tumor. The dosimetric results from MCNP5 code were exported to SISCODES program, which generated isodose curves representing absorbed dose rate in the brain. Isodose curves, neutron fluency, and dose components from BNCT and 252 Cf brachytherapy are presented in this paper. (author)

  18. Dosimetric advantages of intensity-modulated proton therapy for oropharyngeal cancer compared with intensity-modulated radiation: A case-matched control analysis

    Energy Technology Data Exchange (ETDEWEB)

    Holliday, Emma B. [Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX (United States); Kocak-Uzel, Esengul [Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX (United States); Department of Radiation Therapy, Beykent University, Istanbul (Turkey); Feng, Lei [Department of Biostatistics, The University of Texas MD Anderson Cancer Center, Houston, TX (United States); Thaker, Nikhil G.; Blanchard, Pierre; Rosenthal, David I.; Gunn, G. Brandon; Garden, Adam S. [Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX (United States); Frank, Steven J., E-mail: sjfrank@mdanderson.org [Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX (United States)

    2016-10-01

    A potential advantage of intensity-modulated proton therapy (IMPT) over intensity-modulated (photon) radiation therapy (IMRT) in the treatment of oropharyngeal carcinoma (OPC) is lower radiation dose to several critical structures involved in the development of nausea and vomiting, mucositis, and dysphagia. The purpose of this study was to quantify doses to critical structures for patients with OPC treated with IMPT and compare those with doses on IMRT plans generated for the same patients and with a matched cohort of patients actually treated with IMRT. In this study, 25 patients newly diagnosed with OPC were treated with IMPT between 2011 and 2012. Comparison IMRT plans were generated for these patients and for additional IMRT-treated controls extracted from a database of patients with OPC treated between 2000 and 2009. Cases were matched based on the following criteria, in order: unilateral vs bilateral therapy, tonsil vs base of tongue primary, T-category, N-category, concurrent chemotherapy, induction chemotherapy, smoking status, sex, and age. Results showed that the mean doses to the anterior and posterior oral cavity, hard palate, larynx, mandible, and esophagus were significantly lower with IMPT than with IMRT comparison plans generated for the same cohort, as were doses to several central nervous system structures involved in the nausea and vomiting response. Similar differences were found when comparing dose to organs at risks (OARs) between the IMPT cohort and the case-matched IMRT cohort. In conclusion, these findings suggest that patients with OPC treated with IMPT may experience fewer and less severe side effects during therapy. This may be the result of decreased beam path toxicities with IMPT due to lower doses to several dysphagia, odynophagia, and nausea and vomiting–associated OARs. Further study is needed to evaluate differences in long-term disease control and chronic toxicity between patients with OPC treated with IMPT in comparison to

  19. Use of secondary phosphorescence for determination of the dose absorbed in dosimetric phosphors

    CERN Document Server

    Yaek, I V

    2002-01-01

    The measuring method of optically stimulated persistence (OSP) based on both the time division of the stimulating irradiation and luminescent response registration was applied for the radiation dosimetry. It was shown that the stimulation by the short-wave radiation crossing with spectrum of the dosimetric phosphor is possible. The spectrum of the stimulation of industry dosimetric phosphors was measured. The characteristics of the OSP registration for the phosphors which has manganese Mn sup 2 sup + as the activator is considered. Decay time of inner center luminescence is 40-50 ms. This method is used for the dosimetry of the natural quartzes to determine their age.

  20. Dosimetric characteristics of Thermo-Shield material for orthovoltage photon beams

    International Nuclear Information System (INIS)

    Bahmaid, Mohammad; Kim, Siyong; Liu, Chihray R.; Palta, Jatinder R.

    2003-01-01

    Conventionally, lead has been used for field shaping in orthovoltage radiation therapy. Recently, a compensator material named Thermo-Shield was presented for field shaping in electron beams. Thermo-Shield is composed of nontoxic, high atomic weight metal particles dispersed in a thermoplastic matrix. It is manually moldable and conforms to human anatomy or any shape at temperatures of 108-132 degree sign F. It is reusable and can be continuously reshaped to better fit the treatment field. Dosimetric characteristics of thermoplastic material were studied for Philips RT250 orthovoltage photon beams ranging from 75 to 250 kVp. It was found that Thermo-Shield should be four to five times thicker than lead to achieve the same transmission (less than 5%). However, it did not cause significant degradation in penumbra. Clinical procedures for use are discussed

  1. Better Efficacy of Synchrotron Spatially Microfractionated Radiation Therapy Than Uniform Radiation Therapy on Glioma

    International Nuclear Information System (INIS)

    Bouchet, Audrey; Bräuer-Krisch, Elke; Prezado, Yolanda; El Atifi, Michèle; Rogalev, Léonid; Le Clec'h, Céline; Laissue, Jean Albert; Pelletier, Laurent; Le Duc, Géraldine

    2016-01-01

    Purpose: Synchrotron microbeam radiation therapy (MRT) is based on the spatial fractionation of the incident, highly focused synchrotron beam into arrays of parallel microbeams, typically a few tens of microns wide and depositing several hundred grays. This irradiation modality was shown to have a high therapeutic impact on tumors, especially in intracranial locations. However, mechanisms responsible for such a property are not fully understood. Methods and Materials: Thanks to recent progress in dosimetry, we compared the effect of MRT and synchrotron broad beam (BB) radiation therapy delivered at comparable doses (equivalent to MRT valley dose) on tumor growth control and on classical radiobiological functions by histologic evaluation and/or transcriptomic analysis. Results: MRT significantly improved survival of rats bearing 9L intracranial glioma compared with BB radiation therapy delivered at a comparable dose (P<.001); the efficacy of MRT and BB radiation therapy was similar when the MRT dose was half that of BB. The greater efficacy of MRT was not correlated with a difference in cell proliferation (Mki67 and proliferating cell nuclear antigen) or in transcriptomic stimulation of angiogenesis (vascular endothelial growth factor A or tyrosine kinase with immunoglobulin-like and epidermal growth factor-like domains 2) but was correlated with a higher cell death rate (factor for apoptosis signals) and higher recruitment of macrophages (tyrosine kinase with immunoglobulin-like and epidermal growth factor-like domains 1 and CD68 transcripts) a few days after MRT. Conclusions: These results show the superiority of MRT over BB radiation therapy when applied at comparable doses, suggesting that spatial fractionation is responsible for a specific and particularly efficient tissue response. The higher induction of cell death and immune cell activation in brain tumors treated by MRT may be involved in such responses.

  2. Better Efficacy of Synchrotron Spatially Microfractionated Radiation Therapy Than Uniform Radiation Therapy on Glioma

    Energy Technology Data Exchange (ETDEWEB)

    Bouchet, Audrey, E-mail: audrey.m.bouchet@gmail.com [Université Grenoble Alpes, Grenoble Institut des Neurosciences, Grenoble (France); Biomedical Beamline, European Synchrotron Radiation Facility, Grenoble (France); Bräuer-Krisch, Elke; Prezado, Yolanda [Biomedical Beamline, European Synchrotron Radiation Facility, Grenoble (France); El Atifi, Michèle [Université Grenoble Alpes, Grenoble Institut des Neurosciences, Grenoble (France); Grenoble University Hospital, Grenoble (France); Rogalev, Léonid; Le Clec' h, Céline [Biomedical Beamline, European Synchrotron Radiation Facility, Grenoble (France); Laissue, Jean Albert [University of Bern, Bern (Switzerland); Pelletier, Laurent, E-mail: laurent.pelletier@ujf-grenoble.fr [Université Grenoble Alpes, Grenoble Institut des Neurosciences, Grenoble (France); Grenoble University Hospital, Grenoble (France); Le Duc, Géraldine [Biomedical Beamline, European Synchrotron Radiation Facility, Grenoble (France)

    2016-08-01

    Purpose: Synchrotron microbeam radiation therapy (MRT) is based on the spatial fractionation of the incident, highly focused synchrotron beam into arrays of parallel microbeams, typically a few tens of microns wide and depositing several hundred grays. This irradiation modality was shown to have a high therapeutic impact on tumors, especially in intracranial locations. However, mechanisms responsible for such a property are not fully understood. Methods and Materials: Thanks to recent progress in dosimetry, we compared the effect of MRT and synchrotron broad beam (BB) radiation therapy delivered at comparable doses (equivalent to MRT valley dose) on tumor growth control and on classical radiobiological functions by histologic evaluation and/or transcriptomic analysis. Results: MRT significantly improved survival of rats bearing 9L intracranial glioma compared with BB radiation therapy delivered at a comparable dose (P<.001); the efficacy of MRT and BB radiation therapy was similar when the MRT dose was half that of BB. The greater efficacy of MRT was not correlated with a difference in cell proliferation (Mki67 and proliferating cell nuclear antigen) or in transcriptomic stimulation of angiogenesis (vascular endothelial growth factor A or tyrosine kinase with immunoglobulin-like and epidermal growth factor-like domains 2) but was correlated with a higher cell death rate (factor for apoptosis signals) and higher recruitment of macrophages (tyrosine kinase with immunoglobulin-like and epidermal growth factor-like domains 1 and CD68 transcripts) a few days after MRT. Conclusions: These results show the superiority of MRT over BB radiation therapy when applied at comparable doses, suggesting that spatial fractionation is responsible for a specific and particularly efficient tissue response. The higher induction of cell death and immune cell activation in brain tumors treated by MRT may be involved in such responses.

  3. Evaluation of dosimetric characteristics of graphene oxide/PVC nanocomposite for gamma radiation applications

    Energy Technology Data Exchange (ETDEWEB)

    Feizi, Shahzad; Malekie, Shahryar; Ziaie, Farhood [Nuclear Science and Technology Research Institute (NSTRI), Karaj (Iran, Islamic Republic of). Radiation Application Research School; Rahighi, Reza; Tayyebi, Ahmad [Univ. of Technology, Tehran (Iran, Islamic Republic of). Dept. of Physics

    2017-04-01

    Graphene oxide-polyvinyl chloride composite was prepared using tetrahydrofuran solvent-assisted dispersion of characterized nano flakes of graphene oxide in polymer matrix. Electrical percolation threshold of GO/PVC nanocomposite was determined via a finite element simulation method with a 2D model and compared with experimental results. A conductive cell with two silver coated walls was designed and fabricated for exploring dosimetric properties of the composite. Some characteristics of the new nanocomposite such as linearity of dose response, repeatability, sensitivity and angular dependence are investigated. According to 2D proposed method, obtained data associated to electrical conductivity of the GO/polymer composite for PVC matrix plotted in different GO weight percentages and had good compatibility (validity) with experimental data. The dose response is linear in the 17-51 mGy dose range and it can be introduced for gamma radiation dosimetry in diagnostic activities.

  4. Is it necessary to repeat CT imaging and replanning during the course of intensity-modulated radiation therapy for locoregionally advanced nasopharyngeal carcinoma?

    International Nuclear Information System (INIS)

    Chen Chuanben; Lin Xiang; Pan Jianji; Fei Zhaodong; Chen Lisha; Bai Penggang

    2013-01-01

    Our aim was to evaluate the volumetric and dosimetric changes of target volumes and organs at risk (OARs) during intensity-modulated radiation therapy (IMRT) for locoregionally advanced nasopharyngeal carcinoma (NPC) and the necessity of replanning. Twenty locoregionally advanced NPC patients treated by concurrent chemotherapy and IMRT were included. CT and MR images were acquired before treatment and at weeks 2, 3, 4, 5 and 6 during treatment. The target volumes and OARs were contoured based on the fused CT-MRI images and hybrid plans were generated. The changes of volume and dosimetry were measured by comparing original plan and hybrid plans. Significant volumetric changes of target volumes and parotid gland were observed. The primary nasopharyngeal tumor (GTVnx), clinical target volume 1 (CTV1), involved lymph nodes (GTVnd) and left and right parotid glands, shrank at a mean rate of 14.7, 11.56, 11.40, 6.54 and 6.78% per treatment week, respectively. There were no significant dosimetric changes in GTVnx, GTVnd, CTV1, spinal cord and brain stem while the differences of dose to left and right parotid glands were significant (F=6.73, P=0.007; F=7.43, P=0.007). Remarkable volumetric changes were observed. However, the dosimetric changes were inconspicuous except for the parotid. Replanning might contribute to protect the parotid gland. (author)

  5. An evaluation of NCRP report 151--radiation shielding design for radiotherapy facilities, and a feasibility study for 6 MV open-door treatments in an existing high-energy radiation therapy bunker

    Science.gov (United States)

    Kildea, John

    This thesis describes a study of shielding design techniques used for radiation therapy facilities that employ megavoltage linear accelerators. Specifically, an evaluation of the shielding design formalism described in NCRP report 151 was undertaken and a feasibility study for open-door 6 MV radiation therapy treatments in existing 6 MV, 18 MV treatment rooms at the Montreal General Hospital (MGH) was conducted. To evaluate the shielding design formalism of NCRP 151, barrier-attenuated equivalent doses were measured for several of the treatment rooms at the MGH and compared with expectations from NCRP 151 calculations. It was found that, while the insight and recommendations of NCRP 151 are very valuable, its dose predictions are not always correct. As such, the NCRP 151 methodology is best used in conjunction with physical measurements. The feasibility study for 6 MV open-door treatments made use of the NCRP 151 formalism, together with physical measurements for realistic 6 MV workloads. The results suggest that, dosimetrically, 6 MV open door treatments are feasible. A conservative estimate for the increased dose at the door arising from such treatments is 0.1 mSv, with a 1/8 occupancy factor, as recommended in NCRP 151, included.

  6. Influence of radiation therapy on T-lymphocyte subpopulations

    International Nuclear Information System (INIS)

    Job, G.

    1984-01-01

    The author claims this to be the first time where monoclonal antibodies are used in a long-term study in order to determine the influence of radiation therapy on T-lymphozyte-subpopulations in patients suffering from malignant growths. The influence of radiation therapy on B-cells, T-cells and macrophages was also checked. Two groups of patients were given two different radiation doses, and examined separately in order to discover possible effects of the dosage. Radiation therapy reduced B- and T-lymphocytes to the same degree as the total lymphozyte population so that their shares in percent remained unchanged. The same was also found for macrophages. Determination of clones and suppressor T-lymphozytes before, during and after radiation showed T-lymphozytes to have a higher resistance against the influence of radiation than clones. Suppressor cells also regenerated more quickly than clones after the end of the therapy. While radiation therapy was applied the clone/suppressor cell ratio dropped to values lower than those of the healthy reference group. After the end of the therapy this quotient dropped even further in some cases while in others it began to rise slowly, but even 6 months after the end of the therapy it was still lower than normal. As a number of diseases show an increased 'immunoregulatory quotient' it would be conceivable to influence this quotient with radiation therapy in order to achieve a therapeutic effect. (orig./MG) [de

  7. External and internal radiation therapy: Past and future directions

    Directory of Open Access Journals (Sweden)

    Sadeghi Mahdi

    2010-01-01

    Full Text Available Cancer is a leading cause of morbidity and mortality in the modern world. Treatment modalities comprise radiation therapy, surgery, chemotherapy and hormonal therapy. Radiation therapy can be performed by using external or internal radiation therapy. However, each method has its unique properties which undertakes special role in cancer treatment, this question is brought up that: For cancer treatment, whether external radiation therapy is more efficient or internal radiation therapy one? To answer this question, we need to consider principles and structure of individual methods. In this review, principles and application of each method are considered and finally these two methods are compared with each other.

  8. Dosimetric complication probability and acoustic analysis of vocal cord region in oropharyngeal carcinoma treated with voice-sparing intensity modulated radiotherapy

    International Nuclear Information System (INIS)

    Jain, S.; Gupta, T.; Agarwal, J.P.; Baccher, G.; Shrivastava, S.K.; Reenadevi; Master, J.

    2008-01-01

    Radiation to larynx has long been associated with speech and voice dysfunction. The objective is to study dosimetric parameters and complication probability of vocal cord region (VCR) and the effect of voice-sparing (VS) in the patients treated with intensity modulated radiotherapy (IMRT). The secondary objective is to describe the post-radiation acoustic voice characteristics and correlate them with the dosimetric parameters. (author)

  9. Evaluating the dosimetric effect of treatment-induced changes in virally mediated head and neck cancer patients

    International Nuclear Information System (INIS)

    Brown, Elizabeth; Owen, Rebecca; Mengersen, Kerrie; Harden, Fiona; Porceddu, Sandro

    2013-01-01

    Patients with virally mediated head and neck cancer (VMHNC) often present with advanced nodal disease that is highly radioresponsive as demonstrated by tumour and nodal regression during treatment. The resultant changes may impact on the planned dose distribution and so adversely affect the therapeutic ratio. The aim of this study was to evaluate the dosimetric effect of treatment-induced anatomical changes in VMHNC patients who had undergone a replan. Thirteen patients with virally mediated oropharyngeal or nasopharyngeal cancer who presented for definitive radiotherapy between 2005 and 2010 and who had a replan generated were investigated. The dosimetric effect of anatomical changes was quantified by comparing dose–volume histograms (DVH) of primary and nodal gross target volumes and organs at risk (OAR), including spinal cord and parotid glands, from the original plan and a comparison plan. Eleven three-dimensional conformal radiation therapy (3DCRT) and two intensity modulated radiation therapy (IMRT) plans were evaluated. Dose to the spinal cord and brainstem increased by 4.1% and 2.6%, respectively. Mean dose to the parotid glands also increased by 3.5%. In contrast, the dose received by 98% of the primary and nodal gross tumour volumes decreased by 0.15% and 0.3%, respectively, when comparing the initial treatment plan to the comparison plan. In this study, treatment-induced anatomical changes had the greatest impact on OAR dose with negligible effect on the dose to nodal gross tumour volumes. In the era of IMRT, accounting for treatment-induced anatomical changes is important as focus is placed on minimizing the acute and long-term side effects of treatment

  10. Modern radiation therapy for extranodal lymphomas

    DEFF Research Database (Denmark)

    Yahalom, Joachim; Illidge, Tim; Specht, Lena

    2015-01-01

    Extranodal lymphomas (ENLs) comprise about a third of all non-Hodgkin lymphomas (NHL). Radiation therapy (RT) is frequently used as either primary therapy (particularly for indolent ENL), consolidation after systemic therapy, salvage treatment, or palliation. The wide range of presentations of ENL...... and treatment planning for the most frequently involved organs. Specifically, detailed recommendations for RT volumes are provided. We have applied the same modern principles of involved site radiation therapy as previously developed and published as guidelines for Hodgkin lymphoma and nodal NHL. We have...... there is a lack of guidelines for the use of RT in the management of ENL. This report presents an effort by the International Lymphoma Radiation Oncology Group (ILROG) to harmonize and standardize the principles of treatment of ENL, and to address the technical challenges of simulation, volume definition...

  11. Radiometric and dosimetric characteristics of HgI2 detectors

    International Nuclear Information System (INIS)

    Zaletin, V.M.; Krivozubov, O.V.; Torlin, M.A.; Fomin, V.I.

    1988-01-01

    The characteristics of HgI 2 detectors in x-ray and gamma detection in applications to radiometric and dosimetric monitoring and as portable instruments for such purposes was considered. Blocks with mosaic and sandwich structures were prepared and tested against each other and, for comparative purposes, against CdTe detectors for relative sensitivities at various gamma-quanta energies. Sensitivity dependencies on gamma radiation energy were plotted for the detector materials and structures as were current dependencies on the dose rate of x rays. Results indicated that the mercury iodide detectors could be used in radiometric and dosimetric measurements at gamma quantum energies up to and in excess of 1000 KeV

  12. Radiation Therapy for Cancer

    Science.gov (United States)

    ... can cause pain. Radiation given to shrink a tumor near the esophagus , which can interfere with a patient’s ability to eat and drink. How is radiation therapy planned for an individual ... show the location of a patient’s tumor and the normal areas around it. These scans ...

  13. Predicting Radiation Pneumonitis After Stereotactic Ablative Radiation Therapy in Patients Previously Treated With Conventional Thoracic Radiation Therapy

    International Nuclear Information System (INIS)

    Liu Hui; Zhang Xu; Vinogradskiy, Yevgeniy Y.; Swisher, Stephen G.; Komaki, Ritsuko; Chang, Joe Y.

    2012-01-01

    Purpose: To determine the incidence of and risk factors for radiation pneumonitis (RP) after stereotactic ablative radiation therapy (SABR) to the lung in patients who had previously undergone conventional thoracic radiation therapy. Methods and Materials: Seventy-two patients who had previously received conventionally fractionated radiation therapy to the thorax were treated with SABR (50 Gy in 4 fractions) for recurrent disease or secondary parenchymal lung cancer (T 10 and mean lung dose (MLD) of the previous plan and the V 10 -V 40 and MLD of the composite plan were also related to RP. Multivariate analysis revealed that ECOG PS scores of 2-3 before SABR (P=.009), FEV1 ≤65% before SABR (P=.012), V 20 ≥30% of the composite plan (P=.021), and an initial PTV in the bilateral mediastinum (P=.025) were all associated with RP. Conclusions: We found that severe RP was relatively common, occurring in 20.8% of patients, and could be predicted by an ECOG PS score of 2-3, an FEV1 ≤65%, a previous PTV spanning the bilateral mediastinum, and V 20 ≥30% on composite (previous RT+SABR) plans. Prospective studies are needed to validate these predictors and the scoring system on which they are based.

  14. TH-F-202-00: MRI for Radiation Therapy

    International Nuclear Information System (INIS)

    2016-01-01

    MRI has excellent soft tissue contrast and can provide both anatomical and physiological information. It is becoming increasingly important in radiation therapy for treatment planning, image-guided radiation therapy, and treatment assessment. It is critically important at this time point to educate and update our medical physicists about MRI to prepare for the upcoming surge of MRI applications in radiation therapy. This session will review important basics of MR physics, pulse sequence designs, and current radiotherapy application, as well as showcase exciting new developments in MRI that can be potentially useful in radiation therapy. Learning Objectives: To learn basics of MR physics and understand the differences between various pulse sequences To review current applications of MRI in radiation therapy.To discuss recent MRI advances for future MRI guided radiation therapy Partly supported by NIH (1R21CA165384).; W. Miller, Research supported in part by Siemens Healthcare; G. Li, My clinical research is in part supported by NIH U54CA137788. I have a collaborative research project with Philips Healthcare.; J. Cai, jing cai

  15. TH-F-202-00: MRI for Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-06-15

    MRI has excellent soft tissue contrast and can provide both anatomical and physiological information. It is becoming increasingly important in radiation therapy for treatment planning, image-guided radiation therapy, and treatment assessment. It is critically important at this time point to educate and update our medical physicists about MRI to prepare for the upcoming surge of MRI applications in radiation therapy. This session will review important basics of MR physics, pulse sequence designs, and current radiotherapy application, as well as showcase exciting new developments in MRI that can be potentially useful in radiation therapy. Learning Objectives: To learn basics of MR physics and understand the differences between various pulse sequences To review current applications of MRI in radiation therapy.To discuss recent MRI advances for future MRI guided radiation therapy Partly supported by NIH (1R21CA165384).; W. Miller, Research supported in part by Siemens Healthcare; G. Li, My clinical research is in part supported by NIH U54CA137788. I have a collaborative research project with Philips Healthcare.; J. Cai, jing cai.

  16. Factors predicting radiation pneumonitis in locally advanced non-small cell lung cancer

    International Nuclear Information System (INIS)

    Kim, Myung Soo; Lee, Ji Hae; Ha, Bo Ram; Lee, Re Na

    2011-01-01

    Thoracic radiotherapy is a major treatment modality of stage III non-small cell lung cancer. The normal lung tissue is sensitive to radiation and radiation pneumonitis is the most important dose-limiting complication of thoracic radiation therapy. This study was performed to identify the clinical and dosimetric parameters related to the risk of radiation pneumonitis after definitive radiotherapy in stage III non-small cell cancer patients. The medical records were reviewed for 49 patients who completed definitive radiation therapy for locally advanced non-small cell lung cancer from August 2000 to February 2010. Radiation therapy was delivered with the daily dose of 1.8 Gy to 2.0 Gy and the total radiation dose ranged from 50.0 Gy to 70.2 Gy (median, 61.2 Gy). Elective nodal irradiation was delivered at a dose of 45.0 Gy to 50.0 Gy. Seven patients (14.3%) were treated with radiation therapy alone and forty two patients (85.7%) were treated with chemotherapy either sequentially or concurrently. Twenty-five cases (51.0%) out of 49 cases experienced radiation pneumonitis. According to the radiation pneumonitis grade, 10 (20.4%) were grade 1, 9 (18.4%) were grade 2, 4 (8.2%) were grade 3, and 2 (4.1%) were grade 4. In the univariate analyses, no clinical factors including age, sex, performance status, smoking history, underlying lung disease, tumor location, total radiation dose and chemotherapy were associated with grade ≥2 radiation pneumonitis. In the subgroup analysis of the chemotherapy group, concurrent rather than sequential chemotherapy was significantly related to grade ≥2 radiation pneumonitis comparing sequential chemotherapy. In the univariate analysis with dosimetric factors, mean lung dose (MLD), V20, V30, V40, MLDipsi, V20ipsi, V30ipsi, and V40ipsi were associated with grade ≥2 radiation pneumonitis. In addition, multivariate analysis showed that MLD and V30 were independent predicting factors for grade ≥2 radiation pneumonitis. Concurrent

  17. Dosimetric comparison of helical tomotherapy, intensity-modulated radiation therapy, volumetric-modulated arc therapy, and 3-dimensional conformal therapy for the treatment of T1N0 glottic cancer

    International Nuclear Information System (INIS)

    Ekici, Kemal; Pepele, Eda K.; Yaprak, Bahaddin; Temelli, Oztun; Eraslan, Aysun F.; Kucuk, Nadir; Altınok, Ayse Y.; Sut, Pelin A.; Alpak, Ozlem D.; Colak, Cemil; Mayadagli, Alpaslan

    2016-01-01

    Various radiotherapy planning methods for T1N0 laryngeal cancer have been proposed to decrease normal tissue toxicity. We compare helical tomotherapy (HT), linac-based intensity-modulated radiation therapy (IMRT), volumetric-modulated arc therapy (VMAT), and 3-D conformal radiotherapy (3D-CRT) techniques for T1N0 laryngeal cancer. Overall, 10 patients with T1N0 laryngeal cancer were selected and evaluated. Furthermore, 10 radiotherapy treatment plans have been created for all 10 patients, including HT, IMRT, VMAT, and 3D-CRT. IMRT, VMAT, and HT plans vs 3D-CRT plans consistently provided superior planning target volume (PTV) coverage. Similar target coverage was observed between the 3 IMRT modalities. Compared with 3D-CRT, IMRT, HT, and VMAT significantly reduced the mean dose to the carotid arteries. VMAT resulted in the lowest mean dose to the submandibular and thyroid glands. Compared with 3D-CRT, IMRT, HT, and VMAT significantly increased the maximum dose to the spinal cord It was observed that the 3 IMRT modalities studied showed superior target coverage with less variation between each plan in comparison with 3D-CRT. The 3D-CRT plans performed better at the D max of the spinal cord. Clinical investigation is warranted to determine if these treatment approaches would translate into a reduction in radiation therapy–induced toxicities.

  18. Experimental dosimetric evaluation in pelvis phantom, subjected to prostate radiation therapy protocol at 15 MV Linac

    Energy Technology Data Exchange (ETDEWEB)

    Matos, Andrea Silva Dias de; Campos, Tarcisio P.R., E-mail: campos@nuclear.ufmg.b [Universidade Federal de Minas Gerais (DEN/UFMG), Belo Horizonte, MG (Brazil). Dept. de Engenharia Nuclear; Dias, Humberto Galvao [Centro de Radioterapia Hospital Luxemburgo, Belo Horizonte, MG (Brazil)

    2011-07-01

    Among the existing malignant neoplasia, the prostate cancer is most common among male population. Due to its high incidence and morbidity, there is a need for investment in advanced technology for better treatment associated with research and social mobilization to prevent the disease. As an efficient method of treatment for such tumor, radiation teletherapy brings favorable results for the patient, particularly when the cancer is diagnosed early. There are, however, the needs to assess the absorbed doses that reach the prostate in the radiation protocols in order to certify the treatment efficacy. The present research goal is to obtain the profile of absorbed dose distributed in a synthetic prostate on male pelvis phantom following a standard radiation therapy protocol. The methodology makes use of a NRI made phantom and a 15MV Linac accelerator. This phantom has anthropomorphic and anthropometric features containing the major internal organs, including bone, prostate, intestine, and bladder. The exposition was made in a 15 MV linear accelerator taken the isocenter in four fields as a 'BOX' of opposing beams. The dosimetry was prepared using GafChromic EBT type 2 radiochromic film and calibration in a solid water phantom. The radiochromic films were digitized on the Microtek Scan Maker 6900XL model scanner operating in the transmission mode and optical density readings based on RGB mode in the computer program Imagedig. The absorbance readings were performed in the spectrophotometer SP-220 mark BIOSPECTRO obtaining calibration curves generated by the collected data. The results reproduce the dose distribution generated in two orthogonal radiochromic films positioned onto the synthetic prostate. Discussions regarding the characteristics of the phantom and methods of irradiation in relation to the achieved dose profile will be addressed. (author)

  19. Experimental dosimetric evaluation in pelvis phantom, subjected to prostate radiation therapy protocol at 15 MV Linac

    International Nuclear Information System (INIS)

    Matos, Andrea Silva Dias de; Campos, Tarcisio P.R.

    2011-01-01

    Among the existing malignant neoplasia, the prostate cancer is most common among male population. Due to its high incidence and morbidity, there is a need for investment in advanced technology for better treatment associated with research and social mobilization to prevent the disease. As an efficient method of treatment for such tumor, radiation teletherapy brings favorable results for the patient, particularly when the cancer is diagnosed early. There are, however, the needs to assess the absorbed doses that reach the prostate in the radiation protocols in order to certify the treatment efficacy. The present research goal is to obtain the profile of absorbed dose distributed in a synthetic prostate on male pelvis phantom following a standard radiation therapy protocol. The methodology makes use of a NRI made phantom and a 15MV Linac accelerator. This phantom has anthropomorphic and anthropometric features containing the major internal organs, including bone, prostate, intestine, and bladder. The exposition was made in a 15 MV linear accelerator taken the isocenter in four fields as a 'BOX' of opposing beams. The dosimetry was prepared using GafChromic EBT type 2 radiochromic film and calibration in a solid water phantom. The radiochromic films were digitized on the Microtek Scan Maker 6900XL model scanner operating in the transmission mode and optical density readings based on RGB mode in the computer program Imagedig. The absorbance readings were performed in the spectrophotometer SP-220 mark BIOSPECTRO obtaining calibration curves generated by the collected data. The results reproduce the dose distribution generated in two orthogonal radiochromic films positioned onto the synthetic prostate. Discussions regarding the characteristics of the phantom and methods of irradiation in relation to the achieved dose profile will be addressed. (author)

  20. Care of the patient receiving radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Yasko, J.M.

    1982-12-01

    External radiation therapy, or teletherapy, is the use of ionizing radiation to destroy cancer cells. Clinical use of ionizing radiation as treatment for cancer began with the discovery of x-rays in 1895, the identification of natural radioactivity (radium) in 1896, and the first reported cure of cancer, a basal cell epithelioma, induced by radiation in 1899. Initially, radiation was administered as a single large dose and produced severe, life-threatening side effects. The basis for the use of ionizing radiation in daily increments for a period of weeks was provided by Regaud in 1922; ten years later, Coutard clinically developed the method of dose fractionation, which remains in use today. Although the use of ionizing radiation as a treatment is over eighty years old, only in recent years have advancements in its clinical application been based on research related to the biologic effect of radiation on human cells. To effectively care for the patient prior to, during, and at the completion of external radiation therapy, the nurse must know the physical and biologic basis of external radiation therapy and its clinical application.

  1. Care of the patient receiving radiation therapy

    International Nuclear Information System (INIS)

    Yasko, J.M.

    1982-01-01

    External radiation therapy, or teletherapy, is the use of ionizing radiation to destroy cancer cells. Clinical use of ionizing radiation as treatment for cancer began with the discovery of x-rays in 1895, the identification of natural radioactivity (radium) in 1896, and the first reported cure of cancer, a basal cell epithelioma, induced by radiation in 1899. Initially, radiation was administered as a single large dose and produced severe, life-threatening side effects. The basis for the use of ionizing radiation in daily increments for a period of weeks was provided by Regaud in 1922; ten years later, Coutard clinically developed the method of dose fractionation, which remains in use today. Although the use of ionizing radiation as a treatment is over eighty years old, only in recent years have advancements in its clinical application been based on research related to the biologic effect of radiation on human cells. To effectively care for the patient prior to, during, and at the completion of external radiation therapy, the nurse must know the physical and biologic basis of external radiation therapy and its clinical application

  2. RADIATION THERAPY COMMUNICATION-REIRRADIATION OF A NASAL TUMOR IN A BRACHYCEPHALIC DOG USING INTENSITY MODULATED RADIATION THERAPY.

    Science.gov (United States)

    Rancilio, Nicholas J; Custead, Michelle R; Poulson, Jean M

    2016-09-01

    A 5-year-old spayed female Shih Tzu was referred for evaluation of a nasal transitional carcinoma. A total lifetime dose of 117 Gy was delivered to the intranasal mass in three courses over nearly 2 years using fractionated intensity modulated radiation therapy (IMRT) to spare normal tissues. Clinically significant late normal tissue side effects were limited to bilaterally diminished tear production. The patient died of metastatic disease progression 694 days after completion of radiation therapy course 1. This case demonstrates that retreatment with radiation therapy to high lifetime doses for recurrent local disease may be well tolerated with IMRT. © 2016 American College of Veterinary Radiology.

  3. A Population-Based Comparative Effectiveness Study of Radiation Therapy Techniques in Stage III Non-Small Cell Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Harris, Jeremy P. [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Murphy, James D. [Department of Radiation Medicine and Applied Science, University of California– San Diego, Moores Cancer Center, La Jolla, California (United States); Hanlon, Alexandra L. [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); University of Pennsylvania School of Nursing, Philadelphia, Pennsylvania (United States); Le, Quynh-Thu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, California (United States); Loo, Billy W., E-mail: BWLoo@Stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, California (United States); Diehn, Maximilian, E-mail: diehn@Stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, California (United States); Institute for Stem Cell Biology and Regenerative Medicine, Stanford University School of Medicine, Stanford, California (United States)

    2014-03-15

    Purpose: Concerns have been raised about the potential for worse treatment outcomes because of dosimetric inaccuracies related to tumor motion and increased toxicity caused by the spread of low-dose radiation to normal tissues in patients with locally advanced non-small cell lung cancer (NSCLC) treated with intensity modulated radiation therapy (IMRT). We therefore performed a population-based comparative effectiveness analysis of IMRT, conventional 3-dimensional conformal radiation therapy (3D-CRT), and 2-dimensional radiation therapy (2D-RT) in stage III NSCLC. Methods and Materials: We used the Surveillance, Epidemiology, and End Results (SEER)-Medicare database to identify a cohort of patients diagnosed with stage III NSCLC from 2002 to 2009 treated with IMRT, 3D-CRT, or 2D-RT. Using Cox regression and propensity score matching, we compared survival and toxicities of these treatments. Results: The proportion of patients treated with IMRT increased from 2% in 2002 to 25% in 2009, and the use of 2D-RT decreased from 32% to 3%. In univariate analysis, IMRT was associated with improved overall survival (OS) (hazard ratio [HR] 0.90, P=.02) and cancer-specific survival (CSS) (HR 0.89, P=.02). After controlling for confounders, IMRT was associated with similar OS (HR 0.94, P=.23) and CSS (HR 0.94, P=.28) compared with 3D-CRT. Both techniques had superior OS compared with 2D-RT. IMRT was associated with similar toxicity risks on multivariate analysis compared with 3D-CRT. Propensity score matched model results were similar to those from adjusted models. Conclusions: In this population-based analysis, IMRT for stage III NSCLC was associated with similar OS and CSS and maintained similar toxicity risks compared with 3D-CRT.

  4. Clinical applications of continuous infusion chemotherapy ahd concomitant radiation therapy

    International Nuclear Information System (INIS)

    Rosenthal, C.J.; Rotman, M.

    1986-01-01

    This book presents information on the following topics: theoretical basis and clinical applications of 5-FU as a radiosensitizer; treatment of hepatic metastases from gastro intestingal primaries with split course radiation therapy; combined modality therapy with 5-FU, Mitomycin-C and radiation therapy for sqamous cell cancers; treatment of bladder carcinoma with concomitant infusion chemotherapy and irradiation; a treatment of invasiv bladder cancer by the XRT/5FU protocol; concomitant radiation therapy and doxorubicin by continuous infusion in advanced malignancies; cis platin by continuous infusion with concurrent radiation therapy in malignant tumors; combination of radiation with concomitant continuous adriamycin infusion in a patient with partially excised pleomorphic soft tissue sarcoma of the lower extremeity; treatment of recurrent carcinoma of the paranasal sinuses using concomitant infusion cis-platinum and radiation therapy; hepatic artery infusion for hepatic metastases in combination with hepatic resection and hepatic radiation; study of simultaneous radiation therapy, continuous infusion, 5FU and bolus mitomycin-C; cancer of the esophagus; continuous infusion VP-16, bolus cis-platinum and simultaneous radiation therapy as salvage therapy in small cell bronchogenic carcinoma; and concomitant radiation, mitomycin-C and 5-FU infusion in gastro intestinal cancer

  5. Effect of radiation therapy against intracranial hemangiopericytoma

    Energy Technology Data Exchange (ETDEWEB)

    Uemura, Shozaburo; Kuratsu, Jun-ichi; Hamada, Jun-ichiro; Yoshioka, Susumu; Kochi, Masato; Ushio, Yukitaka [Kumamoto Univ. (Japan). School of Medicine; Nakahara, Tadashi; Kishida, Katsuaki

    1992-06-01

    Seven cases of intracranial hemangiopericytoma were studied retrospectively to investigate the efficacy of radiation therapy. Tumor response evaluated by computed tomography and magnetic resonance imaging was obvious after 20-30 Gy irradiation. The total reduction rate was 80-90% and continued as long as 5-7 months after treatment. In five patients receiving radiation therapy before radical removal, the tumors were easily removed without massive hemorrhage. Histological inspection of specimens after irradiation showed a significant disappearance of tumor cells. Pyknosis frequently occurred in endothelial cells, and proliferating vessels with hyalinoid degeneration were also seen. Reticulin fibers between tumor cells were fewer, split, or absent. Preoperative radiation therapy is useful in the treatment of hemangiopericytoma involving considerable surgical risk. Postoperative radiation therapy should be given even if removal is complete. (author).

  6. Effect of radiation therapy against intracranial hemangiopericytoma

    International Nuclear Information System (INIS)

    Uemura, Shozaburo; Kuratsu, Jun-ichi; Hamada, Jun-ichiro; Yoshioka, Susumu; Kochi, Masato; Ushio, Yukitaka; Nakahara, Tadashi; Kishida, Katsuaki.

    1992-01-01

    Seven cases of intracranial hemangiopericytoma were studied retrospectively to investigate the efficacy of radiation therapy. Tumor response evaluated by computed tomography and magnetic resonance imaging was obvious after 20-30 Gy irradiation. The total reduction rate was 80-90% and continued as long as 5-7 months after treatment. In five patients receiving radiation therapy before radical removal, the tumors were easily removed without massive hemorrhage. Histological inspection of specimens after irradiation showed a significant disappearance of tumor cells. Pyknosis frequently occurred in endothelial cells, and proliferating vessels with hyalinoid degeneration were also seen. Reticulin fibers between tumor cells were fewer, split, or absent. Preoperative radiation therapy is useful in the treatment of hemangiopericytoma involving considerable surgical risk. Postoperative radiation therapy should be given even if removal is complete. (author)

  7. Radiation therapy physics

    CERN Document Server

    1995-01-01

    The aim of this book is to provide a uniquely comprehensive source of information on the entire field of radiation therapy physics. The very significant advances in imaging, computational, and accelerator technologies receive full consideration, as do such topics as the dosimetry of radiolabeled antibodies and dose calculation models. The scope of the book and the expertise of the authors make it essential reading for interested physicians and physicists and for radiation dosimetrists.

  8. Modern radiation therapy for primary cutaneous lymphomas

    DEFF Research Database (Denmark)

    Specht, Lena; Dabaja, Bouthaina; Illidge, Tim

    2015-01-01

    Primary cutaneous lymphomas are a heterogeneous group of diseases. They often remain localized, and they generally have a more indolent course and a better prognosis than lymphomas in other locations. They are highly radiosensitive, and radiation therapy is an important part of the treatment......, either as the sole treatment or as part of a multimodality approach. Radiation therapy of primary cutaneous lymphomas requires the use of special techniques that form the focus of these guidelines. The International Lymphoma Radiation Oncology Group has developed these guidelines after multinational...... meetings and analysis of available evidence. The guidelines represent an agreed consensus view of the International Lymphoma Radiation Oncology Group steering committee on the use of radiation therapy in primary cutaneous lymphomas in the modern era....

  9. Development and application of a dosimetric methodology of therapeutic X radiation beams using a tandem system; Desenvolvimento e aplicacao de metodologia dosimetrica de feixes terapeuticos de raios X com sistema tandem

    Energy Technology Data Exchange (ETDEWEB)

    Sartoris, Carla Eri

    2001-07-01

    In radiotherapy the use of orthovoltage X radiation beams is still recommended; to obtain satisfactory results, a periodic control is necessary to check the performance of the ionization chambers and the radiation beams characteristics. This control is performed by using standard dosimetric procedures, as for example the determination of half-value layers and the absorbed dose rates. A Tandem system was established in this work using a pair of ionization chambers (a thimble type and a superficial type) used for measures in a medical institution, in substitution to the routine conventional procedure of determination of half-value layers using absorbers. The results obtained show the application of this method in dosimetric procedures of orthovoltage beams (radiotherapy) as a complement for a quality control program. (author)

  10. Basic principles and practices of integrated dosimetric passportization of the settlements in Ukraine

    International Nuclear Information System (INIS)

    Lyikhtar'ov, Yi.A.; Kovgan, L.M.; Masyuk, S.V.; Yivanova, O.M.; Chepurnij, M.Yi.; Bojko, Z. N.; Gerasimenko, V.B.

    2015-01-01

    The objective of the review is to demonstrate the results of dosimetric passportization (performed in 1991- 2014) for the settlements of Ukraine which suffered from radioactive contamination caused by the Chornobyl accident. The dosimetric passportization played a key role in the National program on the liquidation of after- math of the Chornobyl accident through all stages of the current radiation situation control and decision support touching upon various types of interventions and social benefits to the population of radioactively contaminated areas. The works being performed under dosimetric passportization did not have analogues among the researches which took place after other large-scale industrial and municipal accidents as well their scales as the duration of both radio-ecological and dosimetric monitoring. The new methodological approaches to the assessment of so-called passport doses of a settlement as well as to the definition of the concept of annual dose being the dose used to make decisions for providing both direct and indirect emergency countermeasures for the settlements of Ukraine became pioneering ones. During all the post-accident period there were issued sixteen collections of general dosimetric passportization data which accumulate the results of hundreds of thousands spectrometric, radiochemical and radiation levels measurements and WBC measurements carried out in 1991-2014. The annual passport doses calculated on the basis of these measurements (including their components) are unique information that quantifies the level and time dynamics of the radiation situation for each of the 2161 settlements of 74 districts in 12 regions during all the post-accident period. Thanks to the works of dosimetric passportization of the settlements of Ukraine there were created databases to be unique in their structure and content with quantitative characteristics of the territorial and temporal distribution, the dynamics of changes of a number of important

  11. Multi-detector computed tomography radiation doses in the follow-up of paediatric neurosurgery patients in KwaZulu-Natal: A dosimetric audit

    Directory of Open Access Journals (Sweden)

    Christopher T. Sikwila

    2014-05-01

    Full Text Available Background: Multi-detector computed tomography (MDCT is the preferred modality for follow-up of paediatric neurosurgery patients. Serial imaging, however, has the disadvantage of an ionising radiation burden, which may be mitigated using the ‘as low as reasonably achievable’ (ALARA principle. Objectives: The primary objectives were to determine the radiation dose exposure in paediatric patients subjected to MDCT imaging following neurosurgery and to compare these values with references in current literature. Our secondary objective was to assess the relationship between radiation dose and clinical scenario. Method: Retrospective descriptive data were collected from all paediatric postsurgical patients (n = 169 between the ages of 0 and 12 years who had their first followed-up scan in the year 2010 and were followed up for six months or less. Dose-length product (DLP and current-time product were collected from the picture archiving and communication system. Demographic data including radiology reports were collected from the hospital information system. The effective doses (ED were calculated from the corresponding DLP using age-adjusted conversion factors. For purposes of comparison with other studies, median dosimetric values were calculated and the children were grouped into three age ranges, namely younger than 3 years, 3–7 years and 8–12 years old. Results: The highest median radiation doses were noted in patients being followed-up for intracranial abscesses (1183 mGy cm in the 8–12 year age group, most of whom were female. The lowest radiation doses were for intracranial shunt follow-ups (447 mGy cm. Median values for DLP, ED and current-time product (mAs were comparable to reference doses in all three age groups. However, our study showed a much broader distribution of values with higher upper limits relative to reference values. Indications for follow-up included shunts (n = 110; 65%, intracranial abscess (n = 31; 18%, subdural

  12. Multi-detector computed tomography radiation doses in the follow-up of paediatric neurosurgery patients in KwaZulu-Natal: A dosimetric audit

    Directory of Open Access Journals (Sweden)

    Christopher T. Sikwila

    2014-04-01

    Full Text Available Background: Multi-detector computed tomography (MDCT is the preferred modality for follow-up of paediatric neurosurgery patients. Serial imaging, however, has the disadvantage of an ionising radiation burden, which may be mitigated using the ‘as low as reasonably achievable’ (ALARA principle. Objectives: The primary objectives were to determine the radiation dose exposure in paediatric patients subjected to MDCT imaging following neurosurgery and to compare these values with references in current literature. Our secondary objective was to assess the relationship between radiation dose and clinical scenario.Method: Retrospective descriptive data were collected from all paediatric postsurgical patients (n = 169 between the ages of 0 and 12 years who had their first followed-up scan in the year 2010 and were followed up for six months or less. Dose-length product (DLP and current-time product were collected from the picture archiving and communication system. Demographic data including radiology reports were collected from the hospital information system. The effective doses (ED were calculated from the corresponding DLP using age-adjusted conversion factors. For purposes of comparison with other studies, median dosimetric values were calculated and the children were grouped into three age ranges, namely younger than 3 years, 3–7 years and 8–12 years old.Results: The highest median radiation doses were noted in patients being followed-up for intracranial abscesses (1183 mGy cm in the 8–12 year age group, most of whom were female. The lowest radiation doses were for intracranial shunt follow-ups (447 mGy cm. Median values for DLP, ED and current-time product (mAs were comparable to reference doses in all three age groups. However, our study showed a much broader distribution of values with higher upper limits relative to reference values. Indications for follow-up included shunts (n = 110; 65%, intracranial abscess (n = 31; 18%, subdural

  13. TH-C-17A-05: Cherenkov Excited Phosphorescence Oxygen (CEPhOx) Imaging During Multi-Beam Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, R; Pogue, B [Dartmouth College, Hanover, NH (United States); Holt, R [Dartmouth College, Hanover, NH - New Hampshire (United States); Esipova, T; Vinogradov, S [University of Pennsylvania, Philadelphia, PA (United States); Gladstone, D [Dartmouth-Hitchcock Medical Center, Hanover, City of Lebanon (Lebanon)

    2014-06-15

    Purpose: Cherenkov radiation is created during external beam radiation therapy that can excite phosphorescence in tissue from oxygen-sensitive, bio-compatible probes. Utilizing the known spatial information of the treatment plan with directed multiple beam angles, Cherenkov Excited Phosphorescence Oxygen (CEPhOx) imaging was realized from the reconstructions of Cherenkov excited phosphorescence lifetime. Methods: Platinum(II)-G4 (PtG4) was used as the oxygen-sensitive phosphorescent probe and added to a oxygenated cylindrical liquid phantom with a oxygenated/deoxygenated cylindrical anomaly. Cherenkov excited phosphorescence was imaged using a time-gated ICCD camera temporallysynchronized to the LINAC pulse output. Lifetime reconstruction was carried out in NIRFAST software. Multiple angles of the incident radiation beam was combined with the location of the prescribed treatment volume (PTV) to improve the tomographic recovery as a function of location. The tissue partial pressure of oxygen (pO2) in the background and PTV was calculated based on the recovered lifetime distribution and Stern-Volmer equation. Additionally a simulation study was performed to examine the accuracy of this technique in the setting of a human brain tumor. Results: Region-based pO2 values in the oxygenated background and oxygenated/deoxygenated PTV were correctly recovered, with the deoxygenated anomaly (15.4 mmHg) easily distinguished from the oxygenated background (143 mmHg). The data acquisition time could be achieved within the normal irradiation time for a human fractionated plan. The simulations indicated that CEPhOx would be a sufficient to sample tumor pO2 sensing from tumors which are larger than 2cm in diameter or within 23mm depth from the surface. Conclusion: CEPhOx could be a novel imaging tool for pO2 assessment during external radiation beam therapy. It is minimally invasive and should work within the established treatment plan of radiation therapy with multiple beams in

  14. Micro-Mini and Nano-Dosimetry and Innovative Technologies in Radiation Therapy (MMND and ITRO2016)

    International Nuclear Information System (INIS)

    2017-01-01

    The biennial MMND (formerly MMD) - IPCT workshops, founded in collaboration with Memorial Sloan Kettering Cancer Center (MSKCC) in 2001, has become an important international multidisciplinary forum for the discussion of advanced dosimetric technology for radiation therapy quality assurance (QA) and space science, as well as advanced technologies for prostate cancer treatment. In more recent years, the interests of participants and the scope of the workshops have extended far beyond prostate cancer treatment alone to include all aspects of radiation therapy, radiation science and technology. We therefore decided to change the name in 2016 to Innovative Technologies in Radiation Oncology (ITRO). MMND ITRO 2016 was held on 26-31 January, 2016 at the beautiful Wrest Point Hotel in Hobart, Tasmania and attracted an outstanding international faculty and nearly 200 delegates from 18 countries (http://mmnditro2016.com/) The MMND 2016 program continued to cover advanced medical physics aspects of IMRT, IGRT, VMAT, SBRT, MRI LINAC, innovative brachytherapy, and synchrotron MRT. The demand for sophisticated real time and high temporal and spatial resolution (down to the submillimetre scale) dosimetry methods and instrumentation for end–to-end QA for these radiotherapy technologies is increasing. Special attention was paid to the contribution of advanced imaging and the application of nanoscience to the recent improvements in imaging and radiotherapy. The last decade has seen great progress in charged particle therapy technology which has spread throughout the world and attracted strong current interest in Australia. This demands a better understanding of the fundamental aspects of ion interactions with biological tissue and the relative biological effectiveness (RBE) of protons and heavy ions. The further development of computational and experimental micro-and nano-dosimetry for ions has important application in radiobiology based treatment planning and space radiation

  15. Physics fundamentals and biological effects of synchrotron radiation therapy

    International Nuclear Information System (INIS)

    Prezado, Y.

    2010-01-01

    The main goal of radiation therapy is to deposit a curative dose in the tumor without exceeding the tolerances in the nearby healthy tissues. For some radioresistant tumors, like gliomas, requiring high doses for complete sterilization, the major obstacle for curative treatment with ionizing radiation remains the limited tolerance of the surrounding healthy tissue. This limitation is particularly severe for brain tumors and, especially important in children, due to the high risk of complications in the development of the central nervous system. In addition, the treatment of tumors close to an organ at risk, like the spinal cord, is also restricted. One possible solution is the development of new radiation therapy techniques exploiting radically different irradiation modes and modifying, in this way, the biological equivalent doses. This is the case of synchrotron radiation therapy (SRT). In this work the three new radiation therapy techniques under development at the European Synchrotron Radiation Facility (ESRF), in Grenoble (France) will be described, namely: synchrotron stereotactic radiation therapy (SSRT), microbeam radiation therapy (MRT) and minibeam radiation therapy. The promising results in the treatment of the high grade brain tumors obtained in preclinical studies have paved the way to the clinical trials. The first patients are expected in the fall of 2010. (Author).

  16. Radiation therapy and late reactions in normal tissues

    International Nuclear Information System (INIS)

    Aoyama, Takashi; Kuroda, Yasumasa

    1998-01-01

    Recent developments in cancer therapy have made us increasingly aware that the quality of life of a patient is as valuable as other benefits received from therapy. This awareness leads to an emphasis on organ and/or function preservation in the course of therapy. In line with this new thinking, greater consideration is placed on radiation therapy as an appropriate modality of cancer therapy. Possible complications in normal tissues, especially those of late reaction type after the therapy must be overcome. This review, therefore, focuses on recent progress of studies on mechanisms of the complications of the late reaction type. An observation of a clinical case concerning a late reaction of spinal cord (radiation myelopathy) and surveys of experimental studies on the mechanisms of late reactions (including radiation pneumonitis and lung fibrosis, and radiation response of vascular endothelial cells) provide a hypothesis that apoptosis through the pathway starting with radiation-induced sphingomyelin hydrolysis may play an important role in causing a variety of late reactions. This insight is based on the fact that radiation also activates protein kinase C which appears to block apoptosis. The mechanisms of late reactions, therefore, may involve a balance between radiation-induced apoptotic death and its down regulation by suppressor mechanisms through protein kinase C. (author)

  17. Dosimetric predictors of radiation-induced pericardial effusion in esophageal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ogino, Ichiro; Watanabe, Shigenobu [Yokohama City University Medical Center, Department of Radiation Oncology, Minami-ku, Yokohama, Kanagawa-prefecture (Japan); Sakamaki, Kentaro [Yokohama City University, Department of Biostatistics, Yokohama City University, Yokohama (Japan); Ogino, Yuka [Tokyo Institute of Technology, Department of Systems and Control Engineering, Tokyo (Japan); Kunisaki, Chikara [Yokohama City University Medical Center, Department of Surgery, Gastroenterological Center, Yokohama (Japan); Kimura, Kazuo [Yokohama City University Medical Center, Division of Cardiology, Yokohama (Japan)

    2017-07-15

    To evaluate the dose-volume parameters of the pericardium and heart in order to reduce the risk of radiation-induced pericardial effusion (PE) and symptomatic PE (SPE) in esophageal cancer patients treated with concurrent chemoradiotherapy. In 86 of 303 esophageal cancer patients, follow-up CT was obtained at least 24 months after concurrent chemoradiotherapy. Correlations between clinical factors, including risk factors for cardiac disease, dosimetric factors, and the incidence of PE and SPE after radiotherapy were analyzed using Cox proportional hazard regression analysis. Significant dosimetric factors with the highest hazard ratios were investigated using zones separated according to their distance from esophagus. PE developed in 49 patients. Univariate analysis showed the mean heart dose, heart V{sub 5}-V{sub 55}, mean pericardium dose, and pericardium V{sub 5}-V{sub 50} to all significantly affect the incidence of PE. Additionally, body surface area was correlated with the incidence of PE in multivariate analysis. Grade 3 and 4 SPE developed in 5 patients. The pericardium V{sub 50} and pericardium D{sub 10} significantly affected the incidence of SPE. The pericardium V{sub 50} in patients with SPE ranged from 17.1 to 21.7%. Factors affecting the incidence of SPE were the V{sub 50} of the pericardium zones within 3 cm and 4 cm of the esophagus. A wide range of radiation doses to the heart and pericardium were related to the incidence of PE. A pericardium V{sub 50} ≤ 17% is important to avoid symptomatic PE in esophageal cancer patients treated with concurrent chemoradiotherapy. (orig.) [German] Beurteilung der Dosis-Volumen-Parameter fuer Perikard und Herz zur Risikoreduzierung eines strahleninduzierten Perikardergusses (PE) und eines symptomatischen PE (SPE) bei mit kombinierter Strahlenchemotherapie behandelten Speiseroehrenkrebspatienten. Bei 86 von 303 Speiseroehrenkrebspatienten wurde mindestens 24 Monate nach der Strahlenchemotherapie ein Kontroll

  18. Bile Acid Malabsorption After Pelvic and Prostate Intensity Modulated Radiation Therapy: An Uncommon but Treatable Condition

    Energy Technology Data Exchange (ETDEWEB)

    Harris, Victoria [Academic Urology Unit, Institute of Cancer Research and The Royal Marsden Hospital, London and Sutton (United Kingdom); Benton, Barbara [Gastroenterology Unit, Institute of Cancer Research and The Royal Marsden Hospital, London and Sutton (United Kingdom); Sohaib, Aslam [Department of Radiology, Institute of Cancer Research and The Royal Marsden Hospital, London and Sutton (United Kingdom); Dearnaley, David [Academic Urology Unit, Institute of Cancer Research and The Royal Marsden Hospital, London and Sutton (United Kingdom); Andreyev, H. Jervoise N., E-mail: j@andreyev.demon.co.uk [Gastroenterology Unit, Institute of Cancer Research and The Royal Marsden Hospital, London and Sutton (United Kingdom)

    2012-12-01

    Purpose: Intensity modulated radiation therapy (IMRT) is a significant therapeutic advance in prostate cancer, allowing increased tumor dose delivery and increased sparing of normal tissues. IMRT planning uses strict dose constraints to nearby organs to limit toxicity. Bile acid malabsorption (BAM) is a treatable disorder of the terminal ileum (TI) that presents with symptoms similar to radiation therapy toxicity. It has not been described in patients receiving RT for prostate cancer in the contemporary era. We describe new-onset BAM in men after IMRT for prostate cancer. Methods and Materials: Diagnosis of new-onset BAM was established after typical symptoms developed, selenium-75 homocholic acid taurine (SeHCAT) scanning showed 7-day retention of <15%, and patients' symptoms unequivocally responded to a bile acid sequestrant. The TI was identified on the original radiation therapy plan, and the radiation dose delivered was calculated and compared with accepted dose-volume constraints. Results: Five of 423 men treated in a prospective series of high-dose prostate and pelvic IMRT were identified with new onset BAM (median age, 65 years old). All reported having normal bowel habits before RT. The volume of TI ranged from 26-141 cc. The radiation dose received by the TI varied between 11.4 Gy and 62.1 Gy (uncorrected). Three of 5 patients had TI treated in excess of 45 Gy (equivalent dose calculated in 2-Gy fractions, using an {alpha}/{beta} ratio of 3) with volumes ranging from 1.6 cc-49.0 cc. One patient had mild BAM (SeHCAT retention, 10%-15%), 2 had moderate BAM (SeHCAT retention, 5%-10%), and 2 had severe BAM (SeHCAT retention, <5%). The 3 patients whose TI received {>=}45 Gy developed moderate to severe BAM, whereas those whose TI received <45 Gy had only mild to moderate BAM. Conclusions: Radiation delivered to the TI during IMRT may cause BAM. Identification of the TI from unenhanced RT planning computed tomography scans is difficult and may impede

  19. Dosimetric verification of brain and head and neck intensity-modulated radiation therapy treatment using EDR2 films and 2D ion chamber array matrix

    Directory of Open Access Journals (Sweden)

    Varatharaj C

    2010-01-01

    Full Text Available Background: The evaluation of the agreement between measured and calculated dose plays an essential role in the quality assurance (QA procedures of intensity-modulated radiation therapy (IMRT. Aim: The purpose of this study is to compare performances of the two dosimetric systems (EDR2 and I′matriXX in the verification of the dose distributions calculated by the TPS for brain and head and neck dynamic IMRT cases. Materials and Methods: The comparison of cumulative fluence by using Kodak extended dose rate (EDR2 and I′matriXX detectors has been done for the evaluation of 10 brain, 10 head and neck IMRT cases treated with 6 MV beams. The parameter used to assess the quality of dose calculation is the gamma-index (g -index method. The acceptance limits for g calculation we have used are 3% and 3 mm respectively for dose agreement and distance to agreement parameters. Statistical analyses were performed by using the paired, two-tailed Student t-test, and P< 0.01 is kept as a threshold for the significance level. Results: The qualitative dose distribution comparison was performed using composite dose distribution in the measurement plane and profiles along various axes for TPS vs. EDR2 film and TPS Vs I′matriXX. The quantitative analysis between the calculated and measured dose distribution was evaluated using DTA and g-index. The percentage of pixels matching with the set DTA and g values are comparable for both with EDR2 film and I′matriXX array detectors. Statistically there was no significant variation observed between EDR2 film and I′matriXX in terms of the mean percentage of pixel passing g for brain cases (98.77 ± 1.03 vs 97.62 ± 1.66, P = 0.0218 and for head and neck cases (97.39 ± 2.13 vs 97.17 ± 1.52%, P = 0.7404. Conclusion: Due to simplicity and fast evaluation process of array detectors, it can be routinely used in busy departments without compromising the measurement accuracy.

  20. Prediction of Radiation Esophagitis in Non–Small Cell Lung Cancer Using Clinical Factors, Dosimetric Parameters, and Pretreatment Cytokine Levels

    Directory of Open Access Journals (Sweden)

    Peter G. Hawkins

    2018-02-01

    Full Text Available Radiation esophagitis (RE is a common adverse event associated with radiotherapy for non–small cell lung cancer (NSCLC. While plasma cytokine levels have been correlated with other forms of radiation-induced toxicity, their association with RE has been less well studied. We analyzed data from 126 patients treated on 4 prospective clinical trials. Logistic regression models based on combinations of dosimetric factors [maximum dose to 2 cubic cm (D2cc and generalized equivalent uniform dose (gEUD], clinical variables, and pretreatment plasma levels of 30 cytokines were developed. Cross-validated estimates of area under the receiver operating characteristic curve (AUC and log likelihood were used to assess prediction accuracy. Dose-only models predicted grade 3 RE with AUC values of 0.750 (D2cc and 0.727 (gEUD. Combining clinical factors with D2cc increased the AUC to 0.779. Incorporating pretreatment cytokine measurements, modeled as direct associations with RE and as potential interactions with the dose-esophagitis association, produced AUC values of 0.758 and 0.773, respectively. D2cc and gEUD correlated with grade 3 RE with odds ratios (ORs of 1.094/Gy and 1.096/Gy, respectively. Female gender was associated with a higher risk of RE, with ORs of 1.09 and 1.112 in the D2cc and gEUD models, respectively. Older age was associated with decreased risk of RE, with ORs of 0.992/year and 0.991/year in the D2cc and gEUD models, respectively. Combining clinical with dosimetric factors but not pretreatment cytokine levels yielded improved prediction of grade 3 RE compared to prediction by dose alone. Such multifactorial modeling may prove useful in directing radiation treatment planning.

  1. Selective use of adjuvant radiation therapy in resectable colorectal adenocarcinoma

    International Nuclear Information System (INIS)

    Cohen, A.M.; Gunderson, L.L.; Welch, C.E.

    1981-01-01

    Colorectal cancer recurs within the operative field in 10-20 per cent of patients undergoing potentially curative surgery. In certain subgroups, the recurrence rate is 20-50 per cent. There are some data to suggest either preoperative or postoperative radiation therapy as an adjuvant to potentially curative surgery can reduce the local operative failure rate. However, since radiation therapy has significant side effects, patient selection to maximize the therapeutic ratio is important. This report defines the criteria at the Massachusetts General Hospital for selection of patients with colorectal cancer for adjuvant radiation therapy, defines radiation therapy-surgery sequencing alternatives used, and describes techniques to reduce radiation side effects. Over a period of three and a half years, 196 patients received adjuvant radiation therapy: 51 patients received either moderate or low dose preoperative radiation therapy to rectal or rectosigmoid cancers, and 161 patients received postoperative radiation therapy to the pelvis or extrapelvic colonic tumor-lymph node beds. Some patients who received low-dose preoperative radiation therapy also received moderate-dose postoperative radiation therapy. We prefer moderate-dose postoperative radiation therapy as the approach most likely to decrease the local recurrence rate with minimal interference with surgical procedures and late small-bowel complications. Patients who received postoperative radiation therapy were those without distant metastases, whose primary tumor pathology revealed macroscopic or extensive microscopic transmural tumor penetration into extraperitoneal tissues. Careful case selection, multiple field techniques, the use of reperitonealization, omental flaps, and retroversion of the uterus into the pelvis were combined with postoperative small-bowel x-rays, bladder distention, and lateral portals to minimize radiation damage to normal structures

  2. Application of influence diagrams to prostate intensity-modulated radiation therapy plan selection

    International Nuclear Information System (INIS)

    Meyer, Juergen; Phillips, Mark H; Cho, Paul S; Kalet, Ira; Doctor, Jason N

    2004-01-01

    The purpose is to incorporate clinically relevant factors such as patient-specific and dosimetric information as well as data from clinical trials in the decision-making process for the selection of prostate intensity-modulated radiation therapy (IMRT) plans. The approach is to incorporate the decision theoretic concept of an influence diagram into the solution of the multiobjective optimization inverse planning problem. A set of candidate IMRT plans was obtained by varying the importance factors for the planning target volume (PTV) and the organ-at-risk (OAR) in combination with simulated annealing to explore a large part of the solution space. The Pareto set for the PTV and OAR was analysed to demonstrate how the selection of the weighting factors influenced which part of the solution space was explored. An influence diagram based on a Bayesian network with 18 nodes was designed to model the decision process for plan selection. The model possessed nodes for clinical laboratory results, tumour grading, staging information, patient-specific information, dosimetric information, complications and survival statistics from clinical studies. A utility node was utilized for the decision-making process. The influence diagram successfully ranked the plans based on the available information. Sensitivity analyses were used to judge the reasonableness of the diagram and the results. In conclusion, influence diagrams lend themselves well to modelling the decision processes for IMRT plan selection. They provide an excellent means to incorporate the probabilistic nature of data and beliefs into one model. They also provide a means for introducing evidence-based medicine, in the form of results of clinical trials, into the decision-making process

  3. SU-F-J-111: A Novel Distance-Dose Weighting Method for Label Fusion in Multi- Atlas Segmentation for Prostate Radiation Therapy

    International Nuclear Information System (INIS)

    Chang, J; Gu, X; Lu, W; Jiang, S; Song, T

    2016-01-01

    Purpose: A novel distance-dose weighting method for label fusion was developed to increase segmentation accuracy in dosimetrically important regions for prostate radiation therapy. Methods: Label fusion as implemented in the original SIMPLE (OS) for multi-atlas segmentation relies iteratively on the majority vote to generate an estimated ground truth and DICE similarity measure to screen candidates. The proposed distance-dose weighting puts more values on dosimetrically important regions when calculating similarity measure. Specifically, we introduced distance-to-dose error (DDE), which converts distance to dosimetric importance, in performance evaluation. The DDE calculates an estimated DE error derived from surface distance differences between the candidate and estimated ground truth label by multiplying a regression coefficient. To determine the coefficient at each simulation point on the rectum, we fitted DE error with respect to simulated voxel shift. The DEs were calculated by the multi-OAR geometry-dosimetry training model previously developed in our research group. Results: For both the OS and the distance-dose weighted SIMPLE (WS) results, the evaluation metrics for twenty patients were calculated using the ground truth segmentation. The mean difference of DICE, Hausdorff distance, and mean absolute distance (MAD) between OS and WS have shown 0, 0.10, and 0.11, respectively. In partial MAD of WS which calculates MAD within a certain PTV expansion voxel distance, the lower MADs were observed at the closer distances from 1 to 8 than those of OS. The DE results showed that the segmentation from WS produced more accurate results than OS. The mean DE error of V75, V70, V65, and V60 were decreased by 1.16%, 1.17%, 1.14%, and 1.12%, respectively. Conclusion: We have demonstrated that the method can increase the segmentation accuracy in rectum regions adjacent to PTV. As a result, segmentation using WS have shown improved dosimetric accuracy than OS. The WS will

  4. SU-F-J-111: A Novel Distance-Dose Weighting Method for Label Fusion in Multi- Atlas Segmentation for Prostate Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Chang, J; Gu, X; Lu, W; Jiang, S [UT Southwestern Medical Center, Dallas, TX (United States); Song, T [Southern Medical University, Guangzhou, Guangdong (China)

    2016-06-15

    Purpose: A novel distance-dose weighting method for label fusion was developed to increase segmentation accuracy in dosimetrically important regions for prostate radiation therapy. Methods: Label fusion as implemented in the original SIMPLE (OS) for multi-atlas segmentation relies iteratively on the majority vote to generate an estimated ground truth and DICE similarity measure to screen candidates. The proposed distance-dose weighting puts more values on dosimetrically important regions when calculating similarity measure. Specifically, we introduced distance-to-dose error (DDE), which converts distance to dosimetric importance, in performance evaluation. The DDE calculates an estimated DE error derived from surface distance differences between the candidate and estimated ground truth label by multiplying a regression coefficient. To determine the coefficient at each simulation point on the rectum, we fitted DE error with respect to simulated voxel shift. The DEs were calculated by the multi-OAR geometry-dosimetry training model previously developed in our research group. Results: For both the OS and the distance-dose weighted SIMPLE (WS) results, the evaluation metrics for twenty patients were calculated using the ground truth segmentation. The mean difference of DICE, Hausdorff distance, and mean absolute distance (MAD) between OS and WS have shown 0, 0.10, and 0.11, respectively. In partial MAD of WS which calculates MAD within a certain PTV expansion voxel distance, the lower MADs were observed at the closer distances from 1 to 8 than those of OS. The DE results showed that the segmentation from WS produced more accurate results than OS. The mean DE error of V75, V70, V65, and V60 were decreased by 1.16%, 1.17%, 1.14%, and 1.12%, respectively. Conclusion: We have demonstrated that the method can increase the segmentation accuracy in rectum regions adjacent to PTV. As a result, segmentation using WS have shown improved dosimetric accuracy than OS. The WS will

  5. Local Control and Toxicity in a Large Cohort of Central Lung Tumors Treated With Stereotactic Body Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Modh, Ankit; Rimner, Andreas [Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, New York (United States); Williams, Eric [Department of Medical Physics Memorial Sloan Kettering Cancer Center, New York, New York (United States); Foster, Amanda; Shah, Mihir [Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, New York (United States); Shi, Weiji; Zhang, Zhigang [Department of Biostatistics, Memorial Sloan Kettering Cancer Center, New York, New York (United States); Gelblum, Daphna Y. [Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, New York (United States); Rosenzweig, Kenneth E. [Department of Radiation Oncology, Mount Sinai Medical Center, New York, New York (United States); Yorke, Ellen D.; Jackson, Andrew [Department of Medical Physics Memorial Sloan Kettering Cancer Center, New York, New York (United States); Wu, Abraham J., E-mail: wua@mskcc.org [Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, New York (United States)

    2014-12-01

    Purpose: Stereotactic body radiation therapy (SBRT) in central lung tumors has been associated with higher rates of severe toxicity. We sought to evaluate toxicity and local control in a large cohort and to identify predictive dosimetric parameters. Methods and Materials: We identified patients who received SBRT for central tumors according to either of 2 definitions. Local failure (LF) was estimated using a competing risks model, and multivariate analysis (MVA) was used to assess factors associated with LF. We reviewed patient toxicity and applied Cox proportional hazard analysis and log-rank tests to assess whether dose-volume metrics of normal structures correlated with pulmonary toxicity. Results: One hundred twenty-five patients received SBRT for non-small cell lung cancer (n=103) or metastatic lesions (n=22), using intensity modulated radiation therapy. The most common dose was 45 Gy in 5 fractions. Median follow-up was 17.4 months. Incidence of toxicity ≥ grade 3 was 8.0%, including 5.6% pulmonary toxicity. Sixteen patients (12.8%) experienced esophageal toxicity ≥ grade 2, including 50% of patients in whom PTV overlapped the esophagus. There were 2 treatment-related deaths. Among patients receiving biologically effective dose (BED) ≥80 Gy (n=108), 2-year LF was 21%. On MVA, gross tumor volume (GTV) was significantly associated with LF. None of the studied dose-volume metrics of the lungs, heart, proximal bronchial tree (PBT), or 2 cm expansion of the PBT (“no-fly-zone” [NFZ]) correlated with pulmonary toxicity ≥grade 2. There were no differences in pulmonary toxicity between central tumors located inside the NFZ and those outside the NFZ but with planning target volume (PTV) intersecting the mediastinum. Conclusions: Using moderate doses, SBRT for central lung tumors achieves acceptable local control with low rates of severe toxicity. Dosimetric analysis showed no significant correlation between dose to the lungs, heart, or NFZ and

  6. Circulating miR-29a and miR-150 correlate with delivered dose during thoracic radiation therapy for non-small cell lung cancer

    International Nuclear Information System (INIS)

    Dinh, Tru-Khang T.; Fendler, Wojciech; Chałubińska-Fendler, Justyna; Acharya, Sanket S.; O’Leary, Colin; Deraska, Peter V.; D’Andrea, Alan D.; Chowdhury, Dipanjan; Kozono, David

    2016-01-01

    Risk of normal tissue toxicity limits the amount of thoracic radiation therapy (RT) that can be routinely prescribed to treat non-small cell lung cancer (NSCLC). An early biomarker of response to thoracic RT may provide a way to predict eventual toxicities—such as radiation pneumonitis—during treatment, thereby enabling dose adjustment before the symptomatic onset of late effects. MicroRNAs (miRNAs) were studied as potential serological biomarkers for thoracic RT. As a first step, we sought to identify miRNAs that correlate with delivered dose and standard dosimetric factors. We performed miRNA profiling of plasma samples obtained from five patients with Stage IIIA NSCLC at five dose-points each during radical thoracic RT. Candidate miRNAs were then assessed in samples from a separate cohort of 21 NSCLC patients receiving radical thoracic RT. To identify a cellular source of circulating miRNAs, we quantified in vitro miRNA expression intracellularly and within secreted exosomes in five NSCLC and stromal cell lines. miRNA profiling of the discovery cohort identified ten circulating miRNAs that correlated with delivered RT dose as well as other dosimetric parameters such as lung V20. In the validation cohort, miR-29a-3p and miR-150-5p were reproducibly shown to decrease with increasing radiation dose. Expression of miR-29a-3p and miR-150-5p in secreted exosomes decreased with radiation. This was concomitant with an increase in intracellular levels, suggesting that exosomal export of these miRNAs may be downregulated in both NSCLC and stromal cells in response to radiation. miR-29a-3p and miR-150-5p were identified as circulating biomarkers that correlated with delivered RT dose. miR-150 has been reported to decrease in the circulation of mammals exposed to radiation while miR-29a has been associated with fibrosis in the human heart, lungs, and kidneys. One may therefore hypothesize that outlier levels of circulating miR-29a-3p and miR-150-5p may eventually help

  7. Biokinetic and dosimetric studies of 188Re-hyaluronic acid: a new radiopharmaceutical for treatment of hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Melendez-Alafort, Laura; Nadali, Anna; Zangoni, Elena; Banzato, Alessandra; Rondina, Maria; Rosato, Antonio; Mazzi, Ulderico

    2009-01-01

    Hepatocellular carcinoma (HCC) is the most common primary liver cancer and has very limited therapeutic options. Recently, it has been found that hyaluronic acid (HA) shows selective binding to CD44 receptors expressed in most cancer histotypes. Since the trend in cancer treatment is the use of targeted radionuclide therapy, the aim of this research was to label HA with rhenium-188 and to evaluate its potential use as a hepatocarcinoma therapeutic radiopharmaceutical. Methods: 188 Re-HA was prepared by a direct labelling method to produce a ReO(O-COO) 2 -type coordination complex. 188 Re-HA protein binding and its stability in saline, phosphate buffer, human serum and cysteine solutions were determined. Biokinetic and dosimetric data were estimated in healthy mice (n=60) using the Medical Internal Radiation Dose methodology and mouse model beta-absorbed fractions. To evaluate liver toxicity, alanine aminotranferase (AST) and aspartate aminotranferase (ALT) levels in mice were assessed and the liver maximum tolerated dose (MTD) of 188 Re-HA was determined. Results: A stable complex of 188 Re-HA was obtained with high radiochemical purity (>90%) and low serum protein binding (2%). Biokinetic studies showed a rapid blood clearance (T 1/2 α=21 min). Four hours after administration, 188 Re-HA was almost totally removed from the blood by the liver due to the selective uptake via HA-specific receptors (73.47±5.11% of the injected dose). The liver MTD in mice was ∼40 Gy after 7.4 MBq of 188 Re-HA injection. Conclusions: 188 Re-HA complex showed good stability, pharmacokinetic and dosimetric characteristics that confirm its potential as a new agent for HCC radiation therapy.

  8. Extramammary Paget's disease: role of radiation therapy

    International Nuclear Information System (INIS)

    Guerrieri, M.; Back, M.F.

    2002-01-01

    Extra mammary Paget's disease (EMPD) is an uncommon premalignant skin condition that has been traditionally managed with surgery. A report of long-standing Paget's disease with transformation to invasive adenocarcinoma definitively managed with radiation therapy is presented. A review of cases of extramammary Paget's disease treated with radiation therapy is discussed. The use of radiation therapy should be considered in selected cases, as these studies demonstrate acceptable rates of local control when used as an adjunct to surgery, or as a definitive treatment modality. Copyright (2002) Blackwell Science Pty Ltd

  9. Neutron Spectrometry for Radiation Protection Purposes

    International Nuclear Information System (INIS)

    McDonald, Joseph C.

    2001-01-01

    Determination of the dose equivalent is required for radiation protection purposes, however such a determination is quite difficult for neutron radiation. In order to perform accurate dosimetric determinations, it is necessary to acquire information about the neutron fluence spectrum in the workplace as well as the reference radiations used to calibrate dosimetric instruments. This information can then be used to select the appropriate dosimetric instrument, the optimum calibration condition or to establish correction factors that account for the differences in calibration and workplace conditions. For quite some time, neutron spectrometry has been used for these purposes. A brief review of the applications of spectrometers in radiation protection and some recommendations for further development are given here

  10. Neutron spectrometry for radiation protection purposes

    CERN Document Server

    McDonald, J C; Alberts, W G

    2002-01-01

    Determination of the dose equivalent is required for radiation protection purposes, however such a determination is quite difficult for neutron radiation. In order to perform accurate dosimetric determinations, it is advantageous to acquire information about the neutron fluence spectrum in the workplace as well as the reference radiations used to calibrate dosimetric instruments. This information can then be used to select the appropriate dosimetric instrument, the optimum calibration condition or to establish correction factors that account for the differences in calibration and workplace conditions. For quite some time, neutron spectrometry has been used for these purposes. A brief review of the applications of spectrometers in radiation protection and some recommendations for further development are given here.

  11. Poster - Thur Eve - 54: A software solution for ongoing DVH quality assurance in radiation therapy.

    Science.gov (United States)

    Annis, S-L; Zeng, G; Wu, X; Macpherson, M

    2012-07-01

    A program has been developed in MATLAB for use in quality assurance of treatment planning of radiation therapy. It analyzes patient DVH files and compiles dose volume data for review, trending, comparison and analysis. Patient DVH files are exported from the Eclipse treatment planning system and saved according to treatment sites and date. Currently analysis is available for 4 treatment sites; Prostate, Prostate Bed, Lung, and Upper GI, with two functions for data report and analysis: patient-specific and organ-specific. The patient-specific function loads one patient DVH file and reports the user-specified dose volume data of organs and targets. These data can be compiled to an external file for a third party analysis. The organ-specific function extracts a requested dose volume of an organ from the DVH files of a patient group and reports the statistics over this population. A graphical user interface is utilized to select clinical sites, function and structures, and input user's requests. We have implemented this program in planning quality assurance at our center. The program has tracked the dosimetric improvement in GU sites after VMAT was implemented clinically. It has generated dose volume statistics for different groups of patients associated with technique or time range. This program allows reporting and statistical analysis of DVH files. It is an efficient tool for the planning quality control in radiation therapy. © 2012 American Association of Physicists in Medicine.

  12. Study of dosimetric parameters for iodine-125 brachytherapy sources development from IPEN-CNEN/SP using Monte Carlo method

    International Nuclear Information System (INIS)

    Oliveira, Tiago Batista de

    2016-01-01

    Expectations of the World Health Organization for the year 2030 are that the number of cancer deaths is approximately 13.2 million, reflecting the high proportion of this disease in global health issue. With respect to prostate cancer, according to the National Cancer Institute, the number of cases diagnosed worldwide in 2012 was approximately 1.1 million, while in Brazil the data demonstrated the incidence of 68,000 new cases. The treatment of cancer can be performed with surgery (prostatectomy) or radiation therapy. Among radiotherapy, we can highlight the brachytherapy technique, which consists in the introduction of small radioactive sources (seeds) within the prostate, which is delivered a high dose value in the treatment volume and low dose in the surrounding tissues. In Brazil, the medical profession estimates a demand of approximately 8000 seeds / month, and the unit cost of each seed at least US $ 26.00. The AAPM protocol TG-43 recommend the dose-rate constant, radial dose function and anisotropy function for dosimetric analysis LDR brachytherapy seeds. In this work, Monte Carlo simulations were performed in order to assess the dosimetric parameters of the OncoSeed-6711, manufactured by Oncura-GEHealthcare, and a seed developed by Radiation Technology Center, using the MCNP5 code. A 6711 seed, an IPEN seed and the 30 x 30 x 30cm 3 phantom filled with water were modeled to simulate the dose distribution. The 6711 seed parameters were compared with literature, and the results presented relative error less than 0.1% for Λ. In comparison with the 6711 seed, the IPEN model seed dosimetric parameters were similar, account the statistical uncertainty. (author)

  13. WE-AB-BRB-03: Real-Time Volumetric Scintillation Dosimetry for Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Beddar, S. [UT MD Anderson Cancer Center (United States)

    2016-06-15

    Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558

  14. WE-AB-BRB-03: Real-Time Volumetric Scintillation Dosimetry for Radiation Therapy

    International Nuclear Information System (INIS)

    Beddar, S.

    2016-01-01

    Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558

  15. SU-G-206-16: Investigation of Dosimetric Consequence Via Cone-Beam CT Based Dose Reconstruction in Hepatocellular Carcinoma Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Huang, P; Gang, Y; Qin, S; Li, D [Shandong Province Key Laboratory of Medical Physics and Image Processing Technology, School of Physics and Electronics, Shandong Normal University (China); Li, H; Chen, J; Ma, C; Yin, Y [Department of Radiation Oncology, Shandong Cancer Hospital and Institute (China)

    2016-06-15

    Purpose: Many patients with technically unresectable or medically inoperable hepatocellular carcinoma (HCC) had hepatic dosimetric variations as a result of inter-fraction anatomical deformation. This study was conducted to assess the hepatic dosimetric consequences via reconstructing weekly dose in HCC patients receiving three dimensional conformal radiation therapy. Methods: Twenty-one HCC patients with 21 planning CT (pCT) scans and 63 weekly Cone-beam CT (CBCT) scans were enrolled in this investigation. Among them, six patients had been diagnosed of radiation induced liver disease (RILD) and the other fifteen patients had good prognosis after treatment. And each patient had three weekly CBCT before re-planning. In reconstructing CBCT-based weekly dose, we registered pCT to CBCT to provide the correct Hounsfield units for the CBCT using gradient-based deformable image registration (DIR), and this modified CBCT (mCBCT) were introduced to enable dose calculation.To obtain the weekly dosimetric consequences, the initial plan beam configurations and dose constraints were re-applied to mCBCT for performing dose calculation, and the mCBCT were extrapolated to 25 fractions. Besides, the manually delineated contour was propagated automatically onto the mCBCT of the new patient by exploiting the deformation vectors field, and the reconstructed weekly dose was mapped back to pCT to understand the dose distribution difference. Also, weekly dosimetric variations were compared with the hepatic radiation tolerance in terms of D50 and Dmean. Results: Among the twenty-one patients, the three weekly D50 increased by 0.7Gy, 5.1Gy and 6.1Gy, respectively, and Dmean increased by 0.9%, 4.7% and 5.5%, respectively. For patients with RILD, the average values of the third weekly D50 and Dmean were both high than hepatic radiation tolerance, while the values of patients without RILD were below. Conclusion: The planned dose on pCT was not a real dose to the liver, and the liver overdose

  16. Scalp Dose Evaluation According Radiation Therapy Technique of Whole Brain Radiation Therapy

    International Nuclear Information System (INIS)

    Jang, Joon Yung; Park, Soo Yun; Kim, Jong Sik; Choi, Byeong Gi; Song, Gi Won

    2011-01-01

    Opposing portal irradiation with helmet field shape that has been given to a patient with brain metastasis can cause excess dose in patient's scalp, resulting in hair loss. For this reason, this study is to quantitatively analyze scalp dose for effective prevention of hair loss by comparing opposing portal irradiation with scalp-shielding shape and tomotherapy designed to protect patient's scalp with conventional radiation therapy. Scalp dose was measured by using three therapies (HELMET, MLC, TOMO) after five thermo-luminescence dosimeters were positioned along center line of frontal lobe by using RANDO Phantom. Scalp dose and change in dose distribution were compared and analyzed with DVH after radiation therapy plan was made by using Radiation Treatment Planning System (Pinnacle3, Philips Medical System, USA) and 6 MV X-ray (Clinac 6EX, VARIAN, USA). When surface dose of scalp by using thermo-luminescence dosimeters was measured, it was revealed that scalp dose decreased by average 87.44% at each point in MLC technique and that scalp dose decreased by average 88.03% at each point in TOMO compared with HELMET field therapy. In addition, when percentage of volume (V95%, V100%, V105% of prescribed dose) was calculated by using Dose Volume Histogram (DVH) in order to evaluate the existence or nonexistence of hotspot in scalp as to three therapies (HELMET, MLC, TOMO), it was revealed that MLC technique and TOMO plan had good dose coverage and did not have hot spot. Reducing hair loss of a patient who receives whole brain radiotherapy treatment can make a contribution to improve life quality of the patient. It is expected that making good use of opposing portal irradiation with scalp-shielding shape and tomotherapy to protect scalp of a patient based on this study will reduce hair loss of a patient.

  17. Scalp Dose Evaluation According Radiation Therapy Technique of Whole Brain Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Joon Yung; Park, Soo Yun; Kim, Jong Sik; Choi, Byeong Gi; Song, Gi Won [Dept. of Radiation Oncology, Samsung Medical Center, Seoul (Korea, Republic of)

    2011-09-15

    Opposing portal irradiation with helmet field shape that has been given to a patient with brain metastasis can cause excess dose in patient's scalp, resulting in hair loss. For this reason, this study is to quantitatively analyze scalp dose for effective prevention of hair loss by comparing opposing portal irradiation with scalp-shielding shape and tomotherapy designed to protect patient's scalp with conventional radiation therapy. Scalp dose was measured by using three therapies (HELMET, MLC, TOMO) after five thermo-luminescence dosimeters were positioned along center line of frontal lobe by using RANDO Phantom. Scalp dose and change in dose distribution were compared and analyzed with DVH after radiation therapy plan was made by using Radiation Treatment Planning System (Pinnacle3, Philips Medical System, USA) and 6 MV X-ray (Clinac 6EX, VARIAN, USA). When surface dose of scalp by using thermo-luminescence dosimeters was measured, it was revealed that scalp dose decreased by average 87.44% at each point in MLC technique and that scalp dose decreased by average 88.03% at each point in TOMO compared with HELMET field therapy. In addition, when percentage of volume (V95%, V100%, V105% of prescribed dose) was calculated by using Dose Volume Histogram (DVH) in order to evaluate the existence or nonexistence of hotspot in scalp as to three therapies (HELMET, MLC, TOMO), it was revealed that MLC technique and TOMO plan had good dose coverage and did not have hot spot. Reducing hair loss of a patient who receives whole brain radiotherapy treatment can make a contribution to improve life quality of the patient. It is expected that making good use of opposing portal irradiation with scalp-shielding shape and tomotherapy to protect scalp of a patient based on this study will reduce hair loss of a patient.

  18. Cancer of the larynx: radiation therapy. III

    International Nuclear Information System (INIS)

    Wang, C.C.

    1976-01-01

    Radiation therapy is the treatment of choice for a T1 and T2 tumor with normal cord mobility and/or an exophytic lesion. It not only provides excellent control of the disease, but also preserves a good, useful voice in approximately 90 percent of the irradiated patients. For a T2 lesion with impaired cord mobility and/or moderate ulceration, a trial course of radiotherapy is initially given. If the tumor shows good regression and/or a return of normal cord mobility after a dose of 4000 rads, radiation therapy may be continued to a curative dose level, about 6500 rads. Surgery is reserved for treating residual disease six to eight weeks after radiation therapy or for recurrence. A T3 lesion with complete cord fixation and/or deep ulceration with nodes does not respond favorably to radiation therapy, and a planned combination of irradiation and laryngectomy is advised. Disease that extends beyond the larynx, T4, is rarely curable by radiation therapy alone. If the lesion is still operable, a combined approach of radiation and surgery is preferred; if not, palliative radiation therapy is given. Lymph node metastases from laryngeal carcinoma indicate advanced disease and is managed by preoperative irradiation and radical neck dissection. Under a program of therapeutic individualization, two-thirds to three-quarters of patients with cancer of the larynx can be cured by irradiation with preservation of a good, useful voice. In the remainder, the larynx must be sacrificed to save the patient's life. The ultimate control of laryngeal cancer lies in eradicating the extensive primary lesion and metastatic nodes, a common problem in the management of squamous cell carcinoma elsewhere in the body

  19. Whole-brain radiation therapy for brain metastases: detrimental or beneficial?

    International Nuclear Information System (INIS)

    Gemici, Cengiz; Yaprak, Gokhan

    2015-01-01

    Stereotactic radiosurgery is frequently used, either alone or together with whole-brain radiation therapy to treat brain metastases from solid tumors. Certain experts and radiation oncology groups have proposed replacing whole-brain radiation therapy with stereotactic radiosurgery alone for the management of brain metastases. Although randomized trials have favored adding whole-brain radiation therapy to stereotactic radiosurgery for most end points, a recent meta-analysis demonstrated a survival disadvantage for patients treated with whole-brain radiation therapy and stereotactic radiosurgery compared with patients treated with stereotactic radiosurgery alone. However the apparent detrimental effect of adding whole-brain radiation therapy to stereotactic radiosurgery reported in this meta-analysis may be the result of inhomogeneous distribution of the patients with respect to tumor histologies, molecular histologic subtypes, and extracranial tumor stages between the groups rather than a real effect. Unfortunately, soon after this meta-analysis was published, even as an abstract, use of whole-brain radiation therapy in managing brain metastases has become controversial among radiation oncologists. The American Society of Radiation Oncology recently recommended, in their “Choose Wisely” campaign, against routinely adding whole-brain radiation therapy to stereotactic radiosurgery to treat brain metastases. However, this situation creates conflict for radiation oncologists who believe that there are enough high level of evidence for the effectiveness of whole-brain radiation therapy in the treatment of brain metastases

  20. Development of the Nation-Wide Dosimetric Monitoring Network in Ukraine

    International Nuclear Information System (INIS)

    Chumak, V.; Boguslavskaya, A.; Musijachenko, A.

    2004-01-01

    Development of the nation-wide network for monitoring and registration of individual doses is being in progress in Ukraine. The need for urgent action is caused by the fact, that despite wide use of nuclear energy and radiation sources in industry and medicine, there is no centralized dose accounting system in Ukraine, existing dosimetry services operate obsolete manual TLD readers and no methodological unity is observed by the dosimetry services. Presently the mixed dosimetric monitoring is practiced in Ukraine. Nuclear power plants and some major nuclear facilities have their own dosimetry services responsible for dosimetric monitoring of workers. Rest of occupationally exposed persons is monitored by territorial dosimetry laboratories affiliated to sanitary and epidemiology supervision bodies. In total these services cover about 38,000 occupationally exposed workers, including 5,500 in medicine, 16,400 employees of five nuclear power plants and about 16,000 workers dealing with other sources of occupational exposure (industry, research, military). It is prescribed by the governmental decree that three-level united state system assigned to covering all aspects of efficient dosimetric monitoring should be established. The tasks of the system, in particular, are: securing methodical unity of individual dosimetric monitoring; scientific and methodological guidance of individual dosimetric control; procurement of common technical policy regarding nomenclature and operation of instrumentation; implementation of quality assurance programs; development and support of information infrastructure for logging, storage and access to data on individual dosimetric monitoring, in particular - keeping the national registry of individual doses; training and certification of personnel engaged in the system of individual dosimetric monitoring. In its development, the national system will be guided by international experience and will be established according to the best practices

  1. Intensity modulated radiation therapy using laser-accelerated protons: a Monte Carlo dosimetric study

    International Nuclear Information System (INIS)

    Fourkal, E; Li, J S; Xiong, W; Nahum, A; Ma, C-M

    2003-01-01

    In this paper we present Monte Carlo studies of intensity modulated radiation therapy using laser-accelerated proton beams. Laser-accelerated protons coming out of a solid high-density target have broad energy and angular spectra leading to dose distributions that cannot be directly used for therapeutic applications. Through the introduction of a spectrometer-like particle selection system that delivers small pencil beams of protons with desired energy spectra it is feasible to use laser-accelerated protons for intensity modulated radiotherapy. The method presented in this paper is a three-dimensional modulation in which the proton energy spectrum and intensity of each individual beamlet are modulated to yield a homogeneous dose in both the longitudinal and lateral directions. As an evaluation of the efficacy of this method, it has been applied to two prostate cases using a variety of beam arrangements. We have performed a comparison study between intensity modulated photon plans and those for laser-accelerated protons. For identical beam arrangements and the same optimization parameters, proton plans exhibit superior coverage of the target and sparing of neighbouring critical structures. Dose-volume histogram analysis of the resulting dose distributions shows up to 50% reduction of dose to the critical structures. As the number of fields is decreased, the proton modality exhibits a better preservation of the optimization requirements on the target and critical structures. It is shown that for a two-beam arrangement (parallel-opposed) it is possible to achieve both superior target coverage with 5% dose inhomogeneity within the target and excellent sparing of surrounding tissue

  2. Quantitative dosimetric assessment for effect of gold nanoparticles as contrast media on radiotherapy planning

    International Nuclear Information System (INIS)

    Tu, Shu-Ju; Yang, Pei-Ying; Hong, Ji-Hong; Lo, Ching-Jung

    2013-01-01

    In CT planning for radiation therapy, patients may be asked to have a medical procedure of contrast agent (CA) administration as required by their physicians. CA media improve quality of CT images and assist radiation oncologists in delineation of the target or organs with accuracy. However, dosimetric discrepancy may occur between scenarios in which CA media are present in CT planning and absent in treatment delivery. In recent preclinical experiments of small animals, gold nanoparticles (AuNPs) have been identified as an excellent contrast material of x-ray imaging. In this work, we quantitatively evaluate the effect of AuNPs to be used as a potential material of contrast enhancement in radiotherapy planning with an analytical phantom and clinical case. Conray 60, an iodine-based product for contrast enhancement in clinical uses, is included as a comparison. Other additional variables such as different concentrations of CA media, radiation delivery techniques and dose calculation algorithms are included. We consider 1-field AP, 4-field box, 7-field intensity modulated radiation therapy (IMRT) and a recent technique of volumetric modulated arc therapy (VMAT). CA media of AuNPs (Conray 60) with concentrations of 10%, 20%, 30%, 40% and 50% containing 28.2, 56.4, 84.6, 112.8 and 141.0 mg of gold (iodine) per mL were prepared prior to CT scanning. A virtual phantom with a target where nanoparticle media are loaded and clinical case of gastric lymphoma in which the Conray 60 media were given to the patient prior to the CT planning are included for the study. Compared to Conray 60 media with concentration of 10%/50%, Hounsfield units for AuNP media of 10%/50% are 322/1608 higher due to the fact that atomic number of Au (Z=79) is larger than I (Z=53). In consequence, dosimetric discrepancy of AuNPs is magnified between presence and absence of contrast media. It was found in the phantom study that percent dose differences between presence and absence of CA media may be

  3. Optimization of rotational arc station parameter optimized radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Dong, P.; Ungun, B. [Department of Radiation Oncology, Stanford University, Stanford, California 94305 (United States); Boyd, S. [Department of Electrical Engineering, Stanford University, Stanford, California 94305 (United States); Xing, L., E-mail: lei@stanford.edu [Department of Radiation Oncology, Stanford University, Stanford, California 94305 and Department of Electrical Engineering, Stanford University, Stanford, California 94305 (United States)

    2016-09-15

    Purpose: To develop a fast optimization method for station parameter optimized radiation therapy (SPORT) and show that SPORT is capable of matching VMAT in both plan quality and delivery efficiency by using three clinical cases of different disease sites. Methods: The angular space from 0° to 360° was divided into 180 station points (SPs). A candidate aperture was assigned to each of the SPs based on the calculation results using a column generation algorithm. The weights of the apertures were then obtained by optimizing the objective function using a state-of-the-art GPU based proximal operator graph solver. To avoid being trapped in a local minimum in beamlet-based aperture selection using the gradient descent algorithm, a stochastic gradient descent was employed here. Apertures with zero or low weight were thrown out. To find out whether there was room to further improve the plan by adding more apertures or SPs, the authors repeated the above procedure with consideration of the existing dose distribution from the last iteration. At the end of the second iteration, the weights of all the apertures were reoptimized, including those of the first iteration. The above procedure was repeated until the plan could not be improved any further. The optimization technique was assessed by using three clinical cases (prostate, head and neck, and brain) with the results compared to that obtained using conventional VMAT in terms of dosimetric properties, treatment time, and total MU. Results: Marked dosimetric quality improvement was demonstrated in the SPORT plans for all three studied cases. For the prostate case, the volume of the 50% prescription dose was decreased by 22% for the rectum and 6% for the bladder. For the head and neck case, SPORT improved the mean dose for the left and right parotids by 15% each. The maximum dose was lowered from 72.7 to 71.7 Gy for the mandible, and from 30.7 to 27.3 Gy for the spinal cord. The mean dose for the pharynx and larynx was

  4. Optimization of rotational arc station parameter optimized radiation therapy

    International Nuclear Information System (INIS)

    Dong, P.; Ungun, B.; Boyd, S.; Xing, L.

    2016-01-01

    Purpose: To develop a fast optimization method for station parameter optimized radiation therapy (SPORT) and show that SPORT is capable of matching VMAT in both plan quality and delivery efficiency by using three clinical cases of different disease sites. Methods: The angular space from 0° to 360° was divided into 180 station points (SPs). A candidate aperture was assigned to each of the SPs based on the calculation results using a column generation algorithm. The weights of the apertures were then obtained by optimizing the objective function using a state-of-the-art GPU based proximal operator graph solver. To avoid being trapped in a local minimum in beamlet-based aperture selection using the gradient descent algorithm, a stochastic gradient descent was employed here. Apertures with zero or low weight were thrown out. To find out whether there was room to further improve the plan by adding more apertures or SPs, the authors repeated the above procedure with consideration of the existing dose distribution from the last iteration. At the end of the second iteration, the weights of all the apertures were reoptimized, including those of the first iteration. The above procedure was repeated until the plan could not be improved any further. The optimization technique was assessed by using three clinical cases (prostate, head and neck, and brain) with the results compared to that obtained using conventional VMAT in terms of dosimetric properties, treatment time, and total MU. Results: Marked dosimetric quality improvement was demonstrated in the SPORT plans for all three studied cases. For the prostate case, the volume of the 50% prescription dose was decreased by 22% for the rectum and 6% for the bladder. For the head and neck case, SPORT improved the mean dose for the left and right parotids by 15% each. The maximum dose was lowered from 72.7 to 71.7 Gy for the mandible, and from 30.7 to 27.3 Gy for the spinal cord. The mean dose for the pharynx and larynx was

  5. Insufficiency fractures following radiation therapy for gynecologic malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Ikushima, Hitoshi; Takegawa, Yoshihiro; Matsuki, Hirokazu; Yasuda, Hiroaki; Kawanaka, Takashi; Shiba, Atsushi; Kishida, Yoshiomi; Iwamoto, Seiji; Nishitani, Hiromu [Tokushima Univ. (Japan). School of Medicine

    2002-12-01

    The purpose of this study was to investigate the incidence, clinical and radiological findings of insufficiency fractures (IF) of the female pelvis following radiation therapy. We retrospectively reviewed the radiation oncology records of 108 patients with gynecologic malignancies who underwent external beam radiation therapy of the whole pelvis. All patients underwent conventional radiography and computed tomography (CT) scan every 6 months in follow-up after radiation therapy and magnetic resonance imaging (MRI) and radionuclide bone scan were added when the patients complained of pelvic pain. Thirteen of 108 patients (12%) developed IF in the irradiated field with a median interval of 6 months (range 3-51) from the completion of external beam radiation therapy. All patients who developed IF were postmenopausal women. Age of the patients who developed IF was significantly higher than that of the other patients. The parts of IF were sacroiliac joints, pubis, sacral body and 5th lumbar vertebra and six of 14 patients had multiple lesions. Treatment with rest and nonsteroidal anti-inflammatory drugs lead to symptomatic relief in all patients, although symptoms lasted from 3 to 20 months. Radiation-induced pelvic IF following radiation therapy for gynecologic malignancies were frequently observed in the post-menopausal patients within 1 year after external beam radiation therapy. Symmetrical fractures of the bilateral sacroiliac joint and pubis were the characteristic pattern of pelvic IF. All patients healed with conservative treatment, and nobody became non-ambulant. (author)

  6. Intensity-modulated radiation therapy: dynamic MLC (DMLC) therapy, multisegment therapy and tomotherapy. An example of QA in DMLC therapy

    International Nuclear Information System (INIS)

    Webb, S.

    1998-01-01

    Intensity-modulated radiation therapy will make a quantum leap in tumor control. It is the new radiation therapy for the new millennium. The major methods to achieve IMRT are: 1. Dynamic multileaf collimator (DMLC) therapy, 2. multisegment therapy, and 3. tomotherapy. The principles of these 3 techniques are briefly reviewed. Each technique presents unique QA issues which are outlined. As an example this paper will present the results of a recent new study of an important QA concern in DMLC therapy. (orig.) [de

  7. The role of the Secondary Laboratory of Dosimetric calibration in the implementation of the dosimetric magnitudes with radiological protection aims

    International Nuclear Information System (INIS)

    Perez Medina O, V.; Alvarez R, J.T.; Tovar M, V.M.

    2006-01-01

    It is very well-known the paper of the net of secondary laboratories of dosimetric calibration of the OAS in the dissemination of the traceability of the dosimetric magnitudes: kerma in air and absorbed dose in water, to the radiotherapy departments, given the high accuracy and precision that require the radiotherapy treatments. However the LSCD has other important areas at least for the development, implementation and evaluation of dosimetric magnitudes denominated operative magnitudes with ends of radiological protection: environmental equivalent dose H*(10), directional equivalent dose H'(0.07) and personal equivalent dose Hp. In the case of radiological protection the LSCD-ININ has been implementing the infrastructure to give service of personal dosimetry for photons and beta particles in terms of the operative magnitudes. For photons: X and gamma rays, it account with a secondary pattern camera PTW T34035 gauged in H * and Hp in the primary laboratory of Germany PTB. For the case of beta radiation its account with an extrapolation camera PTW 23392 with a secondary pattern kit of sources of the type I, gauged in terms of H'(0.07) in the PTB. (Author)

  8. Comparison of doses received by the hippocampus in patients treated with single isocenter– vs multiple isocenter–based stereotactic radiation therapy to the brain for multiple brain metastases

    International Nuclear Information System (INIS)

    Algan, Ozer; Giem, Jared; Young, Julie; Ali, Imad; Ahmad, Salahuddin; Hossain, Sabbir

    2015-01-01

    To investigate the doses received by the hippocampus and normal brain tissue during a course of stereotactic radiation therapy using a single isocenter (SI)–based or multiple isocenter (MI)–based treatment planning in patients with less than 4 brain metastases. In total, 10 patients with magnetic resonance imaging (MRI) demonstrating 2-3 brain metastases were included in this retrospective study, and 2 sets of stereotactic intensity-modulated radiation therapy (IMRT) treatment plans (SI vs MI) were generated. The hippocampus was contoured on SPGR sequences, and doses received by the hippocampus and the brain were calculated and compared between the 2 treatment techniques. A total of 23 lesions in 10 patients were evaluated. The median tumor volume, the right hippocampus volume, and the left hippocampus volume were 3.15, 3.24, and 2.63 mL, respectively. In comparing the 2 treatment plans, there was no difference in the planning target volume (PTV) coverage except in the tail for the dose-volume histogram (DVH) curve. The only statistically significant dosimetric parameter was the V_1_0_0. All of the other measured dosimetric parameters including the V_9_5, V_9_9, and D_1_0_0 were not significantly different between the 2 treatment planning techniques. None of the dosimetric parameters evaluated for the hippocampus revealed any statistically significant difference between the MI and SI plans. The total brain doses were slightly higher in the SI plans, especially in the lower dose region, although this difference was not statistically different. The use of SI-based treatment plan resulted in a 35% reduction in beam-on time. The use of SI treatments for patients with up to 3 brain metastases produces similar PTV coverage and similar normal tissue doses to the hippocampus and the brain when compared with MI plans. SI treatment planning should be considered in patients with multiple brain metastases undergoing stereotactic treatment.

  9. Comparison of doses received by the hippocampus in patients treated with single isocenter- vs multiple isocenter-based stereotactic radiation therapy to the brain for multiple brain metastases.

    Science.gov (United States)

    Algan, Ozer; Giem, Jared; Young, Julie; Ali, Imad; Ahmad, Salahuddin; Hossain, Sabbir

    2015-01-01

    To investigate the doses received by the hippocampus and normal brain tissue during a course of stereotactic radiation therapy using a single isocenter (SI)-based or multiple isocenter (MI)-based treatment planning in patients with less than 4 brain metastases. In total, 10 patients with magnetic resonance imaging (MRI) demonstrating 2-3 brain metastases were included in this retrospective study, and 2 sets of stereotactic intensity-modulated radiation therapy (IMRT) treatment plans (SI vs MI) were generated. The hippocampus was contoured on SPGR sequences, and doses received by the hippocampus and the brain were calculated and compared between the 2 treatment techniques. A total of 23 lesions in 10 patients were evaluated. The median tumor volume, the right hippocampus volume, and the left hippocampus volume were 3.15, 3.24, and 2.63mL, respectively. In comparing the 2 treatment plans, there was no difference in the planning target volume (PTV) coverage except in the tail for the dose-volume histogram (DVH) curve. The only statistically significant dosimetric parameter was the V100. All of the other measured dosimetric parameters including the V95, V99, and D100 were not significantly different between the 2 treatment planning techniques. None of the dosimetric parameters evaluated for the hippocampus revealed any statistically significant difference between the MI and SI plans. The total brain doses were slightly higher in the SI plans, especially in the lower dose region, although this difference was not statistically different. The use of SI-based treatment plan resulted in a 35% reduction in beam-on time. The use of SI treatments for patients with up to 3 brain metastases produces similar PTV coverage and similar normal tissue doses to the hippocampus and the brain when compared with MI plans. SI treatment planning should be considered in patients with multiple brain metastases undergoing stereotactic treatment. Copyright © 2015 American Association of

  10. Comparison of doses received by the hippocampus in patients treated with single isocenter– vs multiple isocenter–based stereotactic radiation therapy to the brain for multiple brain metastases

    Energy Technology Data Exchange (ETDEWEB)

    Algan, Ozer, E-mail: oalgan@ouhsc.edu; Giem, Jared; Young, Julie; Ali, Imad; Ahmad, Salahuddin; Hossain, Sabbir

    2015-01-01

    To investigate the doses received by the hippocampus and normal brain tissue during a course of stereotactic radiation therapy using a single isocenter (SI)–based or multiple isocenter (MI)–based treatment planning in patients with less than 4 brain metastases. In total, 10 patients with magnetic resonance imaging (MRI) demonstrating 2-3 brain metastases were included in this retrospective study, and 2 sets of stereotactic intensity-modulated radiation therapy (IMRT) treatment plans (SI vs MI) were generated. The hippocampus was contoured on SPGR sequences, and doses received by the hippocampus and the brain were calculated and compared between the 2 treatment techniques. A total of 23 lesions in 10 patients were evaluated. The median tumor volume, the right hippocampus volume, and the left hippocampus volume were 3.15, 3.24, and 2.63 mL, respectively. In comparing the 2 treatment plans, there was no difference in the planning target volume (PTV) coverage except in the tail for the dose-volume histogram (DVH) curve. The only statistically significant dosimetric parameter was the V{sub 100}. All of the other measured dosimetric parameters including the V{sub 95}, V{sub 99}, and D{sub 100} were not significantly different between the 2 treatment planning techniques. None of the dosimetric parameters evaluated for the hippocampus revealed any statistically significant difference between the MI and SI plans. The total brain doses were slightly higher in the SI plans, especially in the lower dose region, although this difference was not statistically different. The use of SI-based treatment plan resulted in a 35% reduction in beam-on time. The use of SI treatments for patients with up to 3 brain metastases produces similar PTV coverage and similar normal tissue doses to the hippocampus and the brain when compared with MI plans. SI treatment planning should be considered in patients with multiple brain metastases undergoing stereotactic treatment.

  11. Correlation of administered activity and dosimetric data in patients treated with 131MIBG therapy

    International Nuclear Information System (INIS)

    Castellani, M.; Chiesa, C.; Aliberti, G.; Maccauro, M.; Seregni, E.; Lorenzoni, A.; Luksch, R.

    2015-01-01

    Full text of publication follows. Aims: the purpose of the study was to optimized 131-MIBG (or 131 I-MIBG) therapy in children and adults patients with neural crest tumors, by correlating the administered pro/KXg activity to whole-body dosimetry and hematologic toxicity. Materials and methods: from September 2003, to June 2012 twenty-four patients (9 children, 15 adults) (13 neuroblastoma, 9 pheochromocytoma/paraganglioma, 2 medullary thyroid carcinoma) treated with 131 I-MIBG were enrolled in the study. In each patient dosimetric estimation was carried out with MIRD method after patient therapy, using imaging acquisition or probe determination (from 1 to 168 hours). Hematological toxicity was evaluated according to WHO grade by weekly blood count for at least 6 weeks or until recovery. Whole Body Dose (WBD) was correlated with administered pro/KXg activity and bone marrow toxicity. Results: a total of forty-five dosimetric studies have been performed, 16/45 in children and 29/45 in adult patients. Administered activity ranged from 7.4 to 16.65 GBq, corresponding in children to 5-21 mCi/KXg (median 10 mCi/KXg) and in adults to 3-7 mCi/KXg. (median 5 mCi/KXg). In 4 patients (3 children, 1 adult) 2 weeks after 131 I-MING therapy autologous stem cell transplantations were performed. Grade II-III hematological toxicity was observed in all children and in 6/15 adult patient. Whole Body Dose ranged from 1 Gy to 3.6 Gy (median 1.7 Gy) in children, meanwhile it ranged between 0.55 and 1.87 Gy (median 0.96 Gy) in adults. In 5/16 children studies WBD was about 2 Gy and one child received a dose of 3.6 Gy (0.4 Gy/GBq), corresponding to an activity of 18 mCi/KXg. Conclusion: contrary to published data in children the pro/KXg activity is not a good predictor of WBD. In these cases WBD calculation can be affected by the presence of large tumor masses which overestimates the absorbed dose. In any case the administration of activity superior to 15 mCi/KXg is known to be associated

  12. Dosimetric verification of a dedicated 3D treatment planning system for episcleral plaque therapy

    International Nuclear Information System (INIS)

    Knutsen, Stig; Hafslund, Rune; Monge, Odd R.; Valen, Harald; Muren, Ludvig Paul; Rekstad, Bernt Louni; Krohn, Joergen; Dahl, Olav

    2001-01-01

    Purpose: Episcleral plaque therapy (EPT) is applied in the management of some malignant ocular tumors. A customized configuration of typically 4 to 20 radioactive seeds is fixed in a gold plaque, and the plaque is sutured to the scleral surface corresponding to the basis of the intraocular tumor, allowing for a localized radiation dose delivery to the tumor. Minimum target doses as high as 100 Gy are directed at malignant tumor sites close to critical normal tissues (e.g., optic disc and macula). Precise dosimetry is therefore fundamental for judging both the risk for normal tissue toxicity and tumor dose prescription. This paper describes the dosimetric verification of a commercially available dedicated treatment planning system (TPS) for EPT when realistic multiple-seed configurations are applied. Materials and Methods: The TPS Bebig Plaque Simulator is used to plan EPT at our institution. Relative dose distributions in a water phantom, including central axis depth dose and off-axis dose profiles for three different plaques, the University of Southern California (USC) No. 9 and the Collaborative Ocular Melanoma Study (COMS) 12-mm and 20-mm plaques, were measured with a diode detector. Each plaque was arranged with realistic multiple 125 I seed configurations. The measured dose distributions were compared to the corresponding dose profiles calculated with the TPS. All measurements were corrected for the angular sensitivity variation of the diode. Results: Single-seed dose distributions measured with our dosimetry setup agreed with previously published data within 3%. For the three multiple-seed plaque configurations, the measured and calculated dose distributions were in good agreement. For the central axis depth doses, the agreement was within 4%, whereas deviations up to 11% were observed in single points far off-axis. Conclusions: The Bebig Plaque Simulator is a reliable TPS for calculating relative dose distributions around realistic multiple 125 I seed

  13. Radiation therapy of Graves' ophthalmopathy. 2; Therapy started time

    Energy Technology Data Exchange (ETDEWEB)

    Kawamura, Toshinori; Koga, Sukehiko (Fujita Health Univ., Toyoake, Aichi (Japan). School of Medicine)

    1994-04-01

    The difference in the improvement of exophthalmos according to the period of starting radiation therapy was investigated for 26 patients of thyroid ophthalmopathy, also taking thyroidism during radiation into consideration. A 4 MV X-ray was used to a total dose of 20 Gy per 2 weeks. The treatment value tended to be better for the patients in whom the period from the appearance of exophthalmos in an euthyroid condition to the start of radiation was less than 12 months; those of a longer period showed poorer improvement. Radiation treatment of a hyperthyroid condition also showed poor results and it was thought it was not an adequately long enough period for the radiation to take effect. As a result, it was considered that the radiation therapy shall be advantageous if started within 12 months after the appearance of exophthalmos in an euthyroid condition. (author).

  14. Dosimetric monitoring in Ukraine - present status and path to the future

    International Nuclear Information System (INIS)

    Chumak, V.; Boguslavskaya, A.

    2005-01-01

    Full text: Ukraine is the country which utilizes radiation in many peaceful areas. So, nuclear energy sector includes 15 power units (including two new units commissioned in 2004), nuclear fuel cycle also include uranium mines, radiation sources are widely used in industry, science and medicine. As a result, about 50,000 occupationally exposed workers require dosimetric monitoring. However, presently dosimetry services in Ukraine cover only about 38,000 occupationally exposed workers, including 9,100 medical professionals, 16,400 employees of 5 nuclear power plants and ca. 12,400 workers dealing with other sources of occupational exposure (industry, research). Territorial dosimetry services, responsible for dosimetric monitoring in industry and medicine operate in 13 of 25 oblasts (regions) of Ukraine. The coverage of critical groups by dosimetric monitoring is variable and ranges from 38 % to 100 % depending on the oblast. With rare exception, instrumentation is represented by outdated manual TLD systems (inaccurate and insufficiently sensitive) capable of measurement of deep photon dose only; no personal monitoring of beta and neutron exposure is possible now. Quality assurance is limited to the annual metrological attestation of the dosimetric instruments. No information exchange infrastructure and dosimetric registry are in place. The dosimetric data is stored in home-made data environments or even in paper log-books, no data on individual doses is conveyed to central depository, which could be easily accessible for regulating authorities. Although the standing law requires elaboration of the United System for monitoring and registration individual doses, little was done so far, mainly due to lack of domestic funding. However, intention is strong to build such network in accordance with the best practice, covering not only the aspects of physical measurement and data storage, but also quality assurance, accreditation programs and training of the local personnel

  15. Radiation therapy among atomic bomb survivors, Hiroshima and Nagasaki

    International Nuclear Information System (INIS)

    Pinkston, J.A.; Antoku, Shigetoshi; Russell, W.J.

    1980-10-01

    In the continuing evaluations of atomic bomb survivors for late radiation effects, not only doses from the A-bombs but those from other radiation sources must be considered, for the latter may be concomitantly acting factors causing bias among these investigations. In the present study, among 73 Hiroshima and 22 Nagasaki Adult Health Study (AHS) subjects who reported receiving radiation therapy, from 1970 through 1979, the medical records of 72 and 20, respectively, were reviewed, and 41 Hiroshima and 14 Nagasaki subjects were confirmed to have received radiation therapy. The data obtained in the present study were pooled with those of the previous investigation on radiation therapy exposures of AHS subjects prior to 1970. A total of 190 subjects have been documented as receiving radiation therapy and their doses were estimated. Energies used in treatments and diseases treated are discussed. Malignancies developed subsequent to radiation therapy in seven cases; five after treatment for malignancies and two after treatment for benign diseases. Neoplasms of 12 AHS subjects may have been induced by earlier radiation therapy; 5 in the earlier study and 7 in the present one. These investigations underscore the need for continued documentation of exposures to ionizing radiation for medical reasons, especially from sources incurring relatively high doses. Bias in assessments of late radiation effects among A-bomb survivors can thus be avoided. (author)

  16. Helical Tomotherapy Versus Single-Arc Intensity-Modulated Arc Therapy: A Collaborative Dosimetric Comparison Between Two Institutions

    International Nuclear Information System (INIS)

    Rong Yi; Tang, Grace; Welsh, James S.; Mohiuddin, Majid M.; Paliwal, Bhudatt; Yu, Cedric X.

    2011-01-01

    Purpose: Both helical tomotherapy (HT) and single-arc intensity-modulated arc therapy (IMAT) deliver radiation using rotational beams with multileaf collimators. We report a dual-institution study comparing dosimetric aspects of these two modalities. Methods and Materials: Eight patients each were selected from the University of Maryland (UMM) and the University of Wisconsin Cancer Center Riverview (UWR), for a total of 16 cases. Four cancer sites including brain, head and neck (HN), lung, and prostate were selected. Single-arc IMAT plans were generated at UMM using Varian RapidArc (RA), and HT plans were generated at UWR using Hi-Art II TomoTherapy. All 16 cases were planned based on the identical anatomic contours, prescriptions, and planning objectives. All plans were swapped for analysis at the same time after final approval. Dose indices for targets and critical organs were compared based on dose-volume histograms, the beam-on time, monitor units, and estimated leakage dose. After the disclosure of comparison results, replanning was done for both techniques to minimize diversity in optimization focus from different operators. Results: For the 16 cases compared, the average beam-on time was 1.4 minutes for RA and 4.8 minutes for HT plans. HT provided better target dose homogeneity (7.6% for RA and 4.2% for HT) with a lower maximum dose (110% for RA and 105% for HT). Dose conformation numbers were comparable, with RA being superior to HT (0.67 vs. 0.60). The doses to normal tissues using these two techniques were comparable, with HT showing lower doses for more critical structures. After planning comparison results were exchanged, both techniques demonstrated improvements in dose distributions or treatment delivery times. Conclusions: Both techniques created highly conformal plans that met or exceeded the planning goals. The delivery time and total monitor units were lower in RA than in HT plans, whereas HT provided higher target dose uniformity.

  17. Detoxication and antiproteolytic therapy of radiation complications

    International Nuclear Information System (INIS)

    Yakhontov, N.E.; Klimov, I.A.; Lavrikova, L.P.; Martynov, A.D.; Provorova, T.P.; Serdyukov, A.S.; Shestakov, A.F.

    1984-01-01

    49 patients with uterine cervix and ovarian carcinomas were treated with detoxication and antiproteolytic therapy of radiation-induced side-effects. The therapy permits to complete without interruption the remote gamma-therapy course and to reduce patients in-hospital periods by 10+- 1 days. The prescription of hemoder intravenous injection in a dose of 450 ml and contrical intramuscular injection (10000 AtrE) in cases of pronounced manifestations of radiation-induced side-effects (asthenia, leukopenia, enterocolitis) for 3 days should be considered an efficient therapy

  18. Transformation of Physical DVHs to Radiobiologically Equivalent Ones in Hypofractionated Radiotherapy Analyzing Dosimetric and Clinical Parameters: A Practical Approach for Routine Clinical Practice in Radiation Oncology

    Directory of Open Access Journals (Sweden)

    Zoi Thrapsanioti

    2013-01-01

    Full Text Available Purpose. The purpose of this study was to transform DVHs from physical to radiobiological ones as well as to evaluate their reliability by correlations of dosimetric and clinical parameters for 50 patients with prostate cancer and 50 patients with breast cancer, who were submitted to Hypofractionated Radiotherapy. Methods and Materials. To achieve this transformation, we used both the linear-quadratic model (LQ model and the Niemierko model. The outcome of radiobiological DVHs was correlated with acute toxicity score according to EORTC/RTOG criteria. Results. Concerning the prostate radiotherapy, there was a significant correlation between RTOG acute rectal toxicity and ( and ( dosimetric parameters, calculated for  Gy. Moreover, concerning the breast radiotherapy there was a significant correlation between RTOG skin toxicity and dosimetric parameter, calculated for both  Gy ( and  Gy (. The new tool seems reliable and user-friendly. Conclusions. Our proposed model seems user-friendly. Its reliability in terms of agreement with the presented acute radiation induced toxicity was satisfactory. However, more patients are needed to extract safe conclusions.

  19. Radiation therapy in patients with hematologic diseases

    International Nuclear Information System (INIS)

    Hennequin, C.; Maylin, C.

    1995-01-01

    Radiation therapy has a significant place in the treatment of hematologic diseases. Irradiation is a key component of the treatment strategy for Hodgkin's disease and has benefited from clinical studies aimed at improving its therapeutic index. There have been many recent improvements, in particular with regard to accuracy of techniques, imagery, dosimetry, and implementation of quality-control procedures. In localized non-Hodgkin's lymphoma, the gold-standard treatment is radiation therapy coupled with a short course of chemotherapy. In contrast, the place of irradiation in disseminated lymphomas remains to be defined. Prophylactic irradiation of the brain is still used in patients with acute lymphoblastic leukemia. Radiation therapy is of value as palliative treatment of bone lesions of myeloma, in chemo-resistant lymphomas, and in relapses of leukemia. Total body irradiation is a cumbersome but irreplaceable method, which has also benefited from recent clinical and biological studies. Optimal radiation therapy with the best possible therapeutic index requires adequate technological and human resources. (authors). 30 refs., 1 tab

  20. Portal imaging practice patterns of children's oncology group institutions: Dosimetric assessment and recommendations for minimizing unnecessary exposure

    International Nuclear Information System (INIS)

    Olch, Arthur J.; Geurts, Mark; Thomadsen, Bruce; Famiglietti, Robin; Chang, Eric L.

    2007-01-01

    Purpose: To determine and analyze the dosimetric consequences of current portal imaging practices for pediatric patients, and make specific recommendations for reducing exposure from portal imaging procedures. Methods and Materials: A survey was sent to approximately 250 Children's Oncology Group (COG) member institutions asking a series of questions about their portal imaging practices. Three case studies are presented with dosimetric analysis to illustrate the magnitude of unintended dose received by nontarget tissues using the most common techniques from the survey. Results: The vast majority of centers use double-exposure portal image techniques with a variety of open field margins. Only 17% of portal images were obtained during treatment, and for other imaging methods, few centers subtract monitor units from the treatment delivery. The number of monitor units used was nearly the same regardless of imager type, including electronic portal imaging devices. Eighty-six percent imaged all fields the first week and 17% imaged all fields every week. An additional 1,112 cm 3 of nontarget tissue received 1 Gy in one of the example cases. Eight new recommendations are made, which will lower nontarget radiation doses with minimal impact on treatment verification accuracy. Conclusion: Based on the survey, changes can be made in portal imaging practices that will lower nontarget doses. It is anticipated that treatment verification accuracy will be minimally affected. Specific recommendations made to decrease the imaging dose and help lower the rate of radiation-induced secondary cancers in children are proposed for inclusion in future COG protocols using radiation therapy

  1. A Dosimetric Comparison of Dose Escalation with Simultaneous Integrated Boost for Locally Advanced Non-Small-Cell Lung Cancer

    Directory of Open Access Journals (Sweden)

    Wenjuan Yang

    2017-01-01

    Full Text Available Background. Many studies have demonstrated that a higher radiotherapy dose is associated with improved outcomes in non-small-cell lung cancer (NSCLC. We performed a dosimetric planning study to assess the dosimetric feasibility of intensity-modulated radiation therapy (IMRT with a simultaneous integrated boost (SIB in locally advanced NSCLC. Methods. We enrolled twenty patients. Five different dose plans were generated for each patient. All plans were prescribed a dose of 60 Gy to the planning tumor volume (PTV. In the three SIB groups, the prescribed dose was 69 Gy, 75 Gy, and 81 Gy in 30 fractions to the internal gross tumor volume (iGTV. Results. The SIB-IMRT plans were associated with a significant increase in the iGTV dose (P < 0.05, without increased normal tissue exposure or prolonged overall treatment time. Significant differences were not observed in the dose to the normal lung in terms of the V5 and V20 among the four IMRT plans. The maximum dose (Dmax in the esophagus moderately increased along with the prescribed dose (P < 0.05. Conclusions. Our results indicated that escalating the dose by SIB-IMRT is dosimetrically feasible; however, systematic evaluations via clinical trials are still warranted. We have designed a further clinical study (which is registered with ClinicalTrials.gov, number NCT02841228.

  2. Initial Report of a Prospective Dosimetric and Clinical Feasibility Trial Demonstrates the Potential of Protons to Increase the Therapeutic Ratio in Breast Cancer Compared With Photons

    Energy Technology Data Exchange (ETDEWEB)

    Bradley, Julie A., E-mail: jbradley@floridaproton.org; Dagan, Roi; Ho, Meng Wei; Rutenberg, Michael; Morris, Christopher G.; Li, Zuofeng; Mendenhall, Nancy P.

    2016-05-01

    Purpose: To compare dosimetric endpoints between proton therapy (PT) and conventional radiation and determine the feasibility of PT for regional nodal irradiation (RNI) in women with breast cancer. Methods and Materials: From 2012 to 2014, 18 women (stage IIA-IIIB) requiring RNI prospectively enrolled on a pilot study. Median age was 51.8 years (range, 42-73 years). The cohort included breast-conserving therapy (BCT) and mastectomy patients and right- and left-sided cancers. Treatment targets and organs at risk were delineated on computed tomography scans, and PT and conventional plans were developed. Toxicity was prospectively recorded using Common Terminology Criteria for Adverse Events version 4.0. A Wilcoxon signed-rank sum test compared the dose-volume parameters. The primary endpoint was a reduction in cardiac V5. Results: Median follow-up was 20 months (range, 2-31 months). For all patients, the PT plan better met the dosimetric goals and was used for treatment. Proton therapy alone was used for 10 patients (9 postmastectomy, 1 after BCT) and combined proton–photon in 8 (6 BCT, 2 postmastectomy with immediate expander reconstruction). Proton therapy improved coverage of level 2 axilla (P=.0005). Adequate coverage of internal mammary nodes was consistently achieved with PT (median D95, 50.3 Gy; range, 46.6-52.1 Gy) but not with conventional radiation therapy (median D95, 48.2 Gy; range, 40.8-55 Gy; P=.0005). Median cardiac V5 was 0.6% with PT and 16.3% with conventional radiation (P<.0001). Median ipsilateral lung V5 and V20 were improved with PT (median V5 35.3% vs 60.5% [P<.0001]; and median V20, 21.6% vs 35.5% [P<.0001]). Grade 3 dermatitis developed in 4 patients (22%), which was the only grade 3 toxicity. No grade 4+ toxicities developed. Conclusion: Proton therapy for RNI after mastectomy or BCT significantly improves cardiac dose, especially for left-sided patients, and lung V5 and V20 in all patients without excessive acute toxicity

  3. Impact of radiation therapy on sexual life

    International Nuclear Information System (INIS)

    Leroy, T.; Gabelle Flandin, I.; Habold, D.; Hannoun-Levi, J.M.

    2012-01-01

    The aim of this study was to evaluate the impact of radiation therapy on sexual life. The analysis was based on a Pubmed literature review. The keywords used for this research were 'sexual, radiation, oncology, and cancer'. After a brief reminder on the anatomy and physiology, we explained the main complications of radiation oncology and their impact on sexual life. Preventive measures and therapeutic possibilities were discussed. Radiation therapy entails local, systematic and psychological after-effects. For women, vaginal stenosis and dyspareunia represent the most frequent side effects. For men, radiation therapy leads to erectile disorders for 25 to 75% of the patients. These complications have an echo often mattering on the patient quality of life of and on their sexual life post-treatment reconstruction. The knowledge of the indications and the various techniques of irradiation allow reducing its potential sexual morbidity. The information and the education of patients are essential, although often neglected. In conclusion, radiation therapy impacts in variable degrees on the sexual life of the patients. Currently, there are not enough preventive and therapeutic means. Patient information and the early screening of the sexual complications are at stake in the support of patients in the reconstruction of their sexual life. (authors)

  4. A Chinese Visible Human-based computational female pelvic phantom for radiation dosimetry simulation

    International Nuclear Information System (INIS)

    Nan, H.; Jinlu, S.; Shaoxiang, Z.; Qing, H.; Li-wen, T.; Chengjun, G.; Tang, X.; Jiang, S. B.; Xiano-lin, Z.

    2010-01-01

    Accurate voxel phantom is needed for dosimetric simulation in radiation therapy for malignant tumors in female pelvic region. However, most of the existing voxel phantoms are constructed on the basis of Caucasian or non-Chinese population. Materials and Methods: A computational framework for constructing female pelvic voxel phantom for radiation dosimetry was performed based on Chinese Visible Human datasets. First, several organs within pelvic region were segmented from Chinese Visible Human datasets. Then, polygonization and voxelization were performed based on the segmented organs and a 3D computational phantom is built in the form of a set of voxel arrays. Results: The generated phantom can be converted and loaded into treatment planning system for radiation dosimetry calculation. From the observed dosimetric results of those organs and structures, we can evaluate their absorbed dose and implement some simulation studies. Conclusion: A voxel female pelvic phantom was developed from Chinese Visible Human datasets. It can be utilized for dosimetry evaluation and planning simulation, which would be very helpful to improve the clinical performance and reduce the radiation toxicity on organ at risk.

  5. Once-Daily Radiation Therapy for Inflammatory Breast Cancer

    International Nuclear Information System (INIS)

    Brown, Lindsay; Harmsen, William; Blanchard, Miran; Goetz, Matthew; Jakub, James; Mutter, Robert; Petersen, Ivy; Rooney, Jessica; Stauder, Michael; Yan, Elizabeth; Laack, Nadia

    2014-01-01

    Purpose: Inflammatory breast cancer (IBC) is a rare and aggressive breast cancer variant treated with multimodality therapy. A variety of approaches intended to escalate the intensity and efficacy of radiation therapy have been reported, including twice-daily radiation therapy, dose escalation, and aggressive use of bolus. Herein, we examine our outcomes for patients treated with once-daily radiation therapy with aggressive bolus utilization, focusing on treatment technique. Methods and Materials: A retrospective review of patients with nonmetastatic IBC treated from January 1, 2000, through December 31, 2010, was performed. Locoregional control (LRC), disease-free survival (DFS), overall survival (OS) and predictors thereof were assessed. Results: Fifty-two women with IBC were identified, 49 (94%) of whom were treated with neoadjuvant chemotherapy. All underwent mastectomy followed by adjuvant radiation therapy. Radiation was delivered in once-daily fractions of 1.8 to 2.25 Gy (median, 2 Gy). Patients were typically treated with daily 1-cm bolus throughout treatment, and 33 (63%) received a subsequent boost to the mastectomy scar. Five-year Kaplan Meier survival estimates for LRC, DFS, and OS were 81%, 56%, and 64%, respectively. Locoregional recurrence was associated with poorer OS (P<.001; hazard ratio [HR], 4.1). Extracapsular extension was associated with worse LRC (P=.02), DFS (P=.007), and OS (P=.002). Age greater than 50 years was associated with better DFS (P=.03). Pathologic complete response was associated with a trend toward improved LRC (P=.06). Conclusions: Once-daily radiation therapy with aggressive use of bolus for IBC results in outcomes consistent with previous reports using various intensified radiation therapy regimens. LRC remains a challenge despite modern systemic therapy. Extracapsular extension, age ≤50 years, and lack of complete response to chemotherapy appear to be associated with worse outcomes. Novel strategies are needed in IBC

  6. Potential for Improved Intelligence Quotient Using Volumetric Modulated Arc Therapy Compared With Conventional 3-Dimensional Conformal Radiation for Whole-Ventricular Radiation in Children

    International Nuclear Information System (INIS)

    Qi, X. Sharon; Stinauer, Michelle; Rogers, Brion; Madden, Jennifer R.; Wilkening, Greta N.; Liu, Arthur K.

    2012-01-01

    Purpose: To compare volumetric modulated arc therapy (VMAT) with 3-dimensional conformal radiation therapy (3D-CRT) in the treatment of localized intracranial germinoma. We modeled the effect of the dosimetric differences on intelligence quotient (IQ). Method and Materials: Ten children with intracranial germinomas were used for planning. The prescription doses were 23.4 Gy to the ventricles followed by 21.6 Gy to the tumor located in the pineal region. For each child, a 3D-CRT and full arc VMAT was generated. Coverage of the target was assessed by computing a conformity index and heterogeneity index. We also generated VMAT plans with explicit temporal lobe sparing and with smaller ventricular margin expansions. Mean dose to the temporal lobe was used to estimate IQ 5 years after completion of radiation, using a patient age of 10 years. Results: Compared with the 3D-CRT plan, VMAT improved conformality (conformity index 1.10 vs 1.85), with slightly higher heterogeneity (heterogeneity index 1.09 vs 1.06). The averaged mean doses for left and right temporal lobes were 31.3 and 31.7 Gy, respectively, for VMAT plans and 37.7 and 37.6 Gy for 3D-CRT plans. This difference in mean temporal lobe dose resulted in an estimated IQ difference of 3.1 points at 5 years after radiation therapy. When the temporal lobes were explicitly included in the VMAT optimization, the mean temporal lobe dose was reduced 5.6-5.7 Gy, resulting in an estimated IQ difference of an additional 3 points. Reducing the ventricular margin from 1.5 cm to 0.5 cm decreased mean temporal lobe dose 11.4-13.1 Gy, corresponding to an estimated increase in IQ of 7 points. Conclusion: For treatment of children with intracranial pure germinomas, VMAT compared with 3D-CRT provides increased conformality and reduces doses to normal tissue. This may result in improvements in IQ in these children.

  7. Targeted Radiation Therapy for Cancer Initiative

    Science.gov (United States)

    2017-11-01

    AWARD NUMBER: W81XWH-08-2-0174 TITLE: Targeted Radiation Therapy for Cancer Initiative PRINCIPAL INVESTIGATOR: Dusten Macdonald, MD...for Cancer Initiative 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Dusten Macdonald, MD 5d. PROJECT NUMBER...Cancer Initiative Final Report INTRODUCTION: The full potential of radiation therapy has not been realized due to the inability to locate and

  8. Stereotactic body radiation therapy versus conventional radiation therapy in patients with early stage non-small cell lung cancer

    DEFF Research Database (Denmark)

    Jeppesen, Stefan Starup; Schytte, Tine; Jensen, Henrik R

    2013-01-01

    Abstract Introduction. Stereotactic body radiation therapy (SBRT) for early stage non-small cell lung cancer (NSCLC) is now an accepted and patient friendly treatment, but still controversy exists about its comparability to conventional radiation therapy (RT). The purpose of this single...... and SBRT predicted improved prognosis. However, staging procedure, confirmation procedure of recurrence and technical improvements of radiation treatment is likely to influence outcomes. However, SBRT seems to be as efficient as conventional RT and is a more convenient treatment for the patients....

  9. Experiences of a secondary laboratory of dosimetric calibration from the radiation protection and hygiene center CPHR in its first year of work and the procedures for quality assessment used in the calibration and quality control service

    International Nuclear Information System (INIS)

    Morales, J.A.; Campa, R.; Jova Sed, L.

    1996-01-01

    Experiences of a secondary laboratory of dosimetric calibration from the Radiation Protection and Hygiene Center (CPHR) in first year of work and the procedures for quality assessment used in the calibration and quality control service of radiotherapeutic equipment. For the yield calibration of the calibrated sources an ionometric method was used using ionizing chambers coupled to electrometers. Those determination were based on dosimetric American Association of Physicists in Medicine (AAPM)

  10. Basic Principles and Practices of Integrated Dosimetric Passportization of the Settlements in Ukraine.

    Science.gov (United States)

    Likhtarov, I A; Kovgan, L M; Masiuk, S V; Ivanova, O M; Chepurny, M I; Boyko, Z N; Gerasymenko, V B

    2015-12-01

    The purpose of the review is to demonstrate the results of dosimetric passportization (performed in 1991-2014) for the settlements of Ukraine which suffered from radioactive contamination caused by the Chornobyl accident. The dosimetric passportization played a key role in the National program on the liquidation of aftermath of the Chornobyl accident directed on recovery through all stages of the current radiation situation control and decision support touching upon various types of interventions and social benefits to the population of radioactively contaminated areas. The works being performed under dosimetric passportization did not have analogues among the researches which took place after other large-scale industrial and municipal accidents as well their scales as the duration of both radio-ecological and dosimetric monitoring.The new methodological approaches to the assessment of so-called passport doses of a settlement as well as to the definition of the concept of annual dose being the dose used to make decisions for providing both direct and indirect emergency countermeasures for the settlements of Ukraine became pioneering ones. During all the post-accident period there were issued sixteen collections of general dosimetric passportization data which accumulate the results of hundreds of thousands spectrometric, radiochemical and radiation levels measurements and WBC measurements carried out in 1991-2014.The annual passport doses calculated on the basis of these measurements (including their components) are unique information that quantifies the level and time dynamics of the radiation situation for each of the 2161 settlements of 74 raions in 12 oblasts during all the post-accident period. Thanks to the works of dosimetric passportization of the settlements of Ukraine there were created databases to be unique in their structure and content with quantitative characteristics of the territorial and temporal distribution, the dynamics of changes of a number

  11. Intensity-modulated radiation therapy.

    Science.gov (United States)

    Goffman, Thomas E; Glatstein, Eli

    2002-07-01

    Intensity-modulated radiation therapy (IMRT) is an increasingly popular technical means of tightly focusing the radiation dose around a cancer. As with stereotactic radiotherapy, IMRT uses multiple fields and angles to converge on the target. The potential for total dose escalation and for escalation of daily fraction size to the gross cancer is exciting. The excitement, however, has greatly overshadowed a range of radiobiological and clinical concerns.

  12. Verification of Dosimetric Commissioning Accuracy of Intensity Modulated Radiation Therapy and Volumetric Modulated Arc Therapy Delivery using Task Group-119 Guidelines.

    Science.gov (United States)

    Kaviarasu, Karunakaran; Nambi Raj, N Arunai; Hamid, Misba; Giri Babu, A Ananda; Sreenivas, Lingampally; Murthy, Kammari Krishna

    2017-01-01

    The purpose of this study is to verify the accuracy of the commissioning of intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) based on the recommendation of the American Association of Physicists in Medicine Task Group 119 (TG-119). TG-119 proposes a set of clinical test cases to verify the accuracy of IMRT planning and delivery system. For these test cases, we generated two sets of treatment plans, the first plan using 7-9 IMRT fields and a second plan utilizing two-arc VMAT technique for both 6 MV and 15 MV photon beams. The template plans of TG-119 were optimized and calculated by Varian Eclipse Treatment Planning System (version 13.5). Dose prescription and planning objectives were set according to the TG-119 goals. The point dose (mean dose to the contoured chamber volume) at the specified positions/locations was measured using compact (CC-13) ion chamber. The composite planar dose was measured with IMatriXX Evaluation 2D array with OmniPro IMRT Software (version 1.7b). The per-field relative gamma was measured using electronic portal imaging device in a way similar to the routine pretreatment patient-specific quality assurance. Our planning results are compared with the TG-119 data. Point dose and fluence comparison data where within the acceptable confident limit. From the obtained data in this study, we conclude that the commissioning of IMRT and VMAT delivery were found within the limits of TG-119.

  13. Protective effect of transparent film dressing on proton therapy induced skin reactions

    International Nuclear Information System (INIS)

    Whaley, Jonathan T; Kirk, Maura; Cengel, Keith; McDonough, James; Bekelman, Justin; Christodouleas, John P

    2013-01-01

    Proton therapy can result in clinically significant radiation dermatitis. In some clinical scenarios, such as lung or breast cancer, the risk of severe radiation dermatitis may limit beam arrangement and prescription doses. Patients undergoing proton therapy for prostate cancer commonly develop mild radiation dermatitis. Herein, we report the outcomes of two prostate cancer patients whose radiation dermatitis appears to have been substantially diminished by transparent film dressings (Beekley stickers). This is a descriptive report of the skin toxicity observed in two patients undergoing proton therapy for prostate cancer at a single institution in 2011. A phantom dosimetric study was performed to evaluate the impact of a transparent film dressing on a beam’s spread out Bragg peak (SOBP). Two patients with low risk prostate cancer were treated with proton therapy to a total dose of 79.2Gy (RBE) in 1.8 Gy (RBE) fractions using two opposed lateral beams daily. Both patients had small circular (2.5 cm diameter) transparent adhesive markers placed on their skin to assist with daily alignment. Patient 1 had markers in place bilaterally for the entirety of treatment. Patient 2 had a marker in place for three weeks on one side and six weeks on the other. Over the course of therapy, both men developed typical Grade 1 radiation dermatitis (asymptomatic erythema) on their hips; however, in both patients, the erythema was substantially decreased beneath the markers. Patient 2 demonstrated less attenuation and thus greater erythema in the skin covered for three weeks compared to the skin covered for six weeks. The difference in skin changes between the covered and uncovered skin persisted for at least 1 month. A phantom study of double scattered beam SOBP with and without the marker in the beam path showed no gross dosimetric effect. Transparent adhesive markers appear to have attenuated radiation dermatitis in these two patients without affecting the SOBP. One patient may

  14. Proton therapy with spot scanning: the Rinecker Proton Therapy Center in Munich. Part 2: Technical and physical aspects

    International Nuclear Information System (INIS)

    Borchert, H. J.; Mayr, M.; Schneider, R. A.; Arnold, M. R.; Geismar, D. E.; Wilms, M.; Wisser, L.; Herbst, M.

    2008-01-01

    The Rinecker Proton Therapy Center (RPTC) in Munich is about to introduce into clinical radiation therapy, a 2D scanning technique (spot scanning) of a single proton pencil beam. It will be available at four gantries and a fifth treatment room allocates a fixed beam unit for a scattering technique. A superconducting cyclotron extracts protons with a constant energy of 250 MeV. Far upstream of the patient follows modulation of the energy with a degrader according to the prescription of the patients treatment planning. A 10 mm pencil beam at full width of half maximum (FWHM) will enable scanning of individual tumour volumes at any depth i.e. 1 minute for a target volume of 1 litre and a dose of 2 Gy. Innovative solutions will be established for other important issues such as dosimetric monitoring, safety concepts and positioning of the patient. The physical characteristics of proton beam spot scanning offer exceptional possibilities in conformal radiation therapy. Together with intensity modulated proton therapy (IMPT) it significantly improves the sparing of organs at risk and of healthy tissues. (author)

  15. Modern role and issues of radiation therapy for benign diseases

    International Nuclear Information System (INIS)

    Miyashita, Tsuguhiro; Tateno, Atsushi; Kumazaki, Tatsuo

    1999-01-01

    Cases of radiation therapy for benign diseases have diminished in number because of recent alternative methods and knowledge about radiation carcinogenesis. In contrast to this tendency, our cases of benign diseases have recently increased. The facts made us reconsider today's radiation therapy of benign diseases. We reviewed 349 patients who were diagnosed as having benign tumors or non-neoplastic conditions and treated by radiation therapy in the past sixteen years. Analyzed items were the annual transition of treatment number, sorts of diseases, patients' age and sex, and the goal of therapy. Of all radiation therapy patients, benign diseases account for 9.26%. The annual percentages were 0.5%, 6.0%, 11.2% and 13.7% at intervals of five years since 1982. The majority was 246 post-operative irradiation for keloids (71%) and 41 pituitary adenomas (12%). Compared with malignant tumors, benign disease patients were statistically younger and female-dominant. Applications of radiation therapy in keloids and pituitary adenomas had definite goals, but were unclear in other rare diseases. Benign diseases should be treated by radiation therapy as the second or third option, provided the patients have serious symptoms and their diseases do not respond to other modalities. It seems to be widely accepted that favorite cases such as keloids and pituitary adenomas are treated by radiation therapy. But, optimal radiation therapies for other rare benign diseases have not been established. Therefore, the building of databases on radiation therapy on benign diseases should be pursued. Since benign disease patients were young and female-dominant and had many remaining years, their carcinogenicity potential should be considered. (author)

  16. Stage IA non-Hodgkin's lymphoma of the Waldeyer's ring; Limited chemotherapy and radiation therapy versus radiation therapy alone

    Energy Technology Data Exchange (ETDEWEB)

    Uematsu, Minoru (Keio Univ. School of Medicine, Tokyo (Japan). Dept. of Radiology Dept. of Radiology, National Defense Medical College, Saitama (Japan)); Kondo, Makoto (Keio Univ. School of Medicine, Tokyo (Japan). Dept. of Radiology); Hiramatsu, Hideko (Keio Univ. School of Medicine, Tokyo (Japan). Dept. of Radiology); Ikeda, Yasuo (Keio Univ. School of Medicine, Tokyo (Japan). Dept. of Hematology); Mikata, Sumio (Chiba Univ. (Japan). School of Medicine); Katayama, Michiaki (Keio Univ. School of Medicine, Tokyo (Japan). Dept. of Radiology); Ito, Hisao (Keio Univ. School of Medicine, Tokyo (Japan). Dept. of Radiology); Kusano, Shoichi (Dept. of Radiology, National Defense Medical College, Saitama (Japan)); Kubo, Asuchishi (Keio Univ. School of Medicine, Tokyo (Japan). Dept. of Radiology)

    1993-01-01

    Seventeen patients with stage IA non-Hodgkin's lymphoma of the Waldeyer's ring were treated with radiation therapy with or without chemotherapy. All lesions were judged as having intermediate grade malignancy in the Working Formulation. Eight patients received combined treatment with three cycles of cylcophosphamide, doxorubicin, vincristine and prednison (CHOP) and radiation therapy with 30 to 40 Gy. Another 9 patients were treated with radiation therapy 40 to 60 Gy alone. After a median follow-up of 69 months, all 8 patients, treated with combined modality were alive and relapse-free whereas 4 of the 9 treated with irradiation alone had relapsed. All relapses occurred transdiaphragmatically. Two of the 4 relapsing patients were saved, but the other two died of the disease. The 5-year relapse-free and cause-specific survival rates were 100% and 100% in the combined modality group, and 56% and 76% in the radiation therapy alone group (relapse-free: p=0.04, cause-specific: p=0.16). There were no serious complications related to treatment, although most patients complained of mouth dryness and most patients given CHOP had paresthesia. Our opinion was that the total impact of these two side-effects on quality of life was less pronounced after combined modality than after radiation therapy alone. Limited chemotherapy and radiation therapy seemed to be more beneficial than radiation therapy alone not only in relapse-free survival but also in quality of life after treatment. (orig.).

  17. CT follow-up after radiation therapy for pituitary adenomas

    International Nuclear Information System (INIS)

    Rush, S.C.; Newall, J.

    1988-01-01

    Between 1973 and 1985, 105 patients received radiation therapy as all or part of their treatment for pituitary tumor at the New York University Medical Center. Of these, 48 patients underwent computed tomography (CT) at a minimum of 2 years following treatment, with detailed reports available for analysis of tumor regression. There were 28 men with a median age of 46 years (range, 18-71 years) and 20 women with a median age of 53 years (range, 28-80 years). Tumors were classified as secretory in 23 patients, nonsecretory in 21, and undetermined in four. Sixteen patients were treated with radiation therapy alone, 23 patients with surgery and radiation therapy, and the other with bromocriptine and radiation therapy, with or without surgery. With a median follow-up of 5 years (range, 2-14 years), 16 patients developed an empty sella, 25 patients had residual sellar mass, and seven patients had persistent extrasellar components or no change in their intrasellar mass. Among patients who did not have hypopituitarism at the inception of radiation therapy, five of 13 with empty sellas and 12 of 22 with residual mass subsequently required therapy. The authors conclude that residual mass is commonly found in long-term follow-up after radiation therapy, that isolated imaging studies revealing such findings after treatment in no way herald a diagnosis of recurrence, and that hypopituitarism following pituitary radiation therapy does not correlate with the ablation or persistence of tissue within the sella

  18. Dosimetric evaluation of a moving tumor target in intensity-modulated radiation therapy (IMRT) for lung cancer patients

    Science.gov (United States)

    Kim, Sung Kyu; Kang, Min Kyu; Yea, Ji Woon; Oh, Se An

    2013-07-01

    Immobilization plays an important role in intensity-modulated radiation therapy (IMRT). The application of IMRT in lung cancer patients is very difficult due to the movement of the tumor target. Patient setup in radiation treatment demands high accuracy because IMRT employs a treatment size of a 1mm pixel unit. Hence, quality assurance of the dose delivered to patients must be at its highest. The radiation dose was evaluated for breathing rates of 9, 14, and 18 breaths per minute (bpm) for tumor targets moving up and down by 1.0 cm and 1.5 cm. The dose of the moving planned target volume (PTV) was measured by using a thermo-luminescent dosimeter (TLD) and Gafchromic™ EBT film. The measurement points were 1.0 cm away from the top, the bottom and the left and the right sides of the PTV center. The evaluated dose differences ranged from 94.2 to 103.8%, from 94.4 to 105.4%, and from 90.7 to 108.5% for 9, 14 and 18 bpm, respectively, for a tumor movement of 1.0 cm. The mean values of the doses were 101.4, 99.9, and 99.5% for 9, 14 and 18 bpm, respectively, for a tumor movement of 1.0 cm. Meanwhile, the evaluated dose differences ranged from 93.6 to 105.8%, from 95.9 to 111.5%, and from 96.2 to 111.7% for 9, 14 and 18 bpm, respectively, for a tumor movement of 1.5 cm. The mean values of the doses were 102.3, 103.4, and 103.1% for 9, 14 and 18 bpm, respectively, for a tumor movement of 1.5 cm. Therefore, we suggest that IMRT can be used in the treatment of lung cancer patients with vertical target movements within the range of 1.0 to 1.5 cm.

  19. Radiation therapy for hypopharyngeal carcinoma. Impact of fractionation on treatment outcome

    International Nuclear Information System (INIS)

    Niibe, Yuzuru; Karasawa, Katsuyuki; Igaki, Hiroshi; Miyashita, Hisao; Tanaka, Yoshiaki

    2003-01-01

    The purpose of the current study was to evaluate the impact of fractionation on the treatment outcome of radiation therapy for hypopharyngeal carcinoma. Thirty-six inoperable or operation-refused hypopharyngeal patients were treated with curative-intended radiation therapy between 1976 and May 2001. Seventeen patients were treated with conventional radiation therapy, 1.8-2.0 Gy per fraction, totaling 64.0 Gy (conventional fractionation (CF) group), and 19 were treated with hyperfractionated radiation therapy, 1.2 Gy per fraction, totaling 74.4 Gy (hyperfractionation (HF) group). The radiation response of the two groups at the end of radiation therapy was almost the same. However, the 2-year local control rates of the HF and CF groups were 59.0% and 26.1% (p=0.012), respectively, a statistically significant differences. Moreover, multivariate analysis showed that HF was an independent prognostic factor for local control. Hyperfractionated radiation therapy was superior to conventional radiation therapy for local control. Local control of hypopharyngeal carcinoma correlated with laryngeal preservation, suggesting that hyperfractionated radiation therapy for hypopharyngeal carcinoma could be beneficial for patient quality of life (QOL). (author)

  20. Researches, development and characterization of dosimetric materials for monitoring in irradiation processes with high doses

    International Nuclear Information System (INIS)

    Galante, Ana Maria Sisti

    2003-01-01

    Dosimetric materials that can be produced in Brazil with material acquired in the national market to replace the imported dosimeters used in radiation processing were developed in this work. Mixtures of potassium nitrate and sensitizers compounds as manganese dioxide, barium nitrate and potassium bromide were prepared in the pellet form. Dosimetric characteristics such as dose-response useful range, sensitivity, environmental conditions and dose rate influences were evaluated in 60 Co gamma radiation fields. Dyed polymethylmethacrylate detectors were also produced and its dosimetric characteristics were evaluated. The main characteristics evaluated in this case were: dose response useful range sensitivity, environmental conditions, dose rate influences and radiation energy dependence in gamma radiation fields and accelerated electrons beam of 0.8 to 1.5 MeV. The applied analytic technique was spectrophotometry. The calibration was performed in the irradiation facilities belonging to IPEN and certified by the International Atomic Energy Agency by means of the program IDAS (International Dose Assurance Service ) using the Fricke dosimeter. The mixture of potassium nitrate and manganese dioxide presented the best results and a wide dose range between 200 and 600 kGy. The response of the developed polymethylmethacrylate detectors are similar to the imported detectors and the dose range is characteristic to each detector and depends on the dye added in its formulation. (author)

  1. Monte Carlo based dosimetry and treatment planning for neutron capture therapy of brain tumors

    International Nuclear Information System (INIS)

    Zamenhof, R.G.; Brenner, J.F.; Wazer, D.E.; Madoc-Jones, H.; Clement, S.D.; Harling, O.K.; Yanch, J.C.

    1990-01-01

    Monte Carlo based dosimetry and computer-aided treatment planning for neutron capture therapy have been developed to provide the necessary link between physical dosimetric measurements performed on the MITR-II epithermal-neutron beams and the need of the radiation oncologist to synthesize large amounts of dosimetric data into a clinically meaningful treatment plan for each individual patient. Monte Carlo simulation has been employed to characterize the spatial dose distributions within a skull/brain model irradiated by an epithermal-neutron beam designed for neutron capture therapy applications. The geometry and elemental composition employed for the mathematical skull/brain model and the neutron and photon fluence-to-dose conversion formalism are presented. A treatment planning program, NCTPLAN, developed specifically for neutron capture therapy, is described. Examples are presented illustrating both one and two-dimensional dose distributions obtainable within the brain with an experimental epithermal-neutron beam, together with beam quality and treatment plan efficacy criteria which have been formulated for neutron capture therapy. The incorporation of three-dimensional computed tomographic image data into the treatment planning procedure is illustrated

  2. State of the art of radiation therapy for esophageal cancer

    International Nuclear Information System (INIS)

    Itasaka, Satoshi

    2014-01-01

    Radiation therapy has a critical role in the treatment of esophageal cancer. To improve the treatment outcome of radiotherapy, not only strengthening the treatment intensity but also decreasing the long term toxicity is needed. To reduce the long term cardiopulmonary toxicity of chemoradiation, JCOG is now running a clinical trial which combines three dimensional conformal radiation therapy (3D-CRT) and mild irradiation dose. New techniques of radiation therapy, such as intensity modulated radiation therapy (IMRT) or particle therapy are also promising in both treatment intensity and decreased toxicity. (author)

  3. Nursing care update: Internal radiation therapy

    International Nuclear Information System (INIS)

    Lowdermilk, D.L.

    1990-01-01

    Internal radiation therapy has been used in treating gynecological cancers for over 100 years. A variety of radioactive sources are currently used alone and in combination with other cancer treatments. Nurses need to be able to provide safe, comprehensive care to patients receiving internal radiation therapy while using precautions to keep the risks of exposure to a minimum. This article discusses current trends and issues related to such treatment for gynecological cancers.20 references

  4. Radiation practices and radiation measurements

    International Nuclear Information System (INIS)

    2008-03-01

    The guide presents the principal requirements on accuracy of radiation measurements and on the approval, calibration and operating condition inspections of radiation meters, together with requirements for dosimetric services measuring the individual radiation doses of workers engaged in radiation work (approved dosimetric services). The Guide also sets out the definitions of quantities and units used in radiation measurements. The radiation protection quantities used for assessing the harmful effects of radiation and for expressing the maximum values for radiation exposure (equivalent dose and effective dose) are set out in Guide ST 7.2. This Guide concerns measurements of ionizing radiation involved in radiation practices, the results of which are used for determining the radiation exposure of workers engaged in radiation work and members of the public, and of patients subject to the use of radiation in health services, or upon the basis of which compliance with safety requirements of appliances currently in use and of their premises of use or of the workplaces of workers is ensured. The Guide also concerns measurements of the radon concentration of inhaled air in both workplaces and dwellings. The Guide does not apply to determining the radiation exposure of aircrews, determination of exposure caused by internal radiation, or measurements made to protect the public in the event of, or in preparation for abnormal radiation conditions

  5. WE-AB-BRB-04: Cherenkov Imaging for Radiation Therapy Dose Verification On Patients

    Energy Technology Data Exchange (ETDEWEB)

    Pogue, B. [Dartmouth College (United States)

    2016-06-15

    Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558

  6. WE-AB-BRB-01: Memorial Introduction; Storage Phosphor Panels for Radiation Therapy Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Li, H. [Washington University School of Medicine (United States)

    2016-06-15

    Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558

  7. WE-AB-BRB-04: Cherenkov Imaging for Radiation Therapy Dose Verification On Patients

    International Nuclear Information System (INIS)

    Pogue, B.

    2016-01-01

    Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558

  8. WE-AB-BRB-01: Memorial Introduction; Storage Phosphor Panels for Radiation Therapy Dosimetry

    International Nuclear Information System (INIS)

    Li, H.

    2016-01-01

    Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558

  9. The role of radiation therapy in the multidisciplinary treatment of patients with malignant tumors. Radiation pathological stand point

    International Nuclear Information System (INIS)

    Niibe, Hideo

    1998-01-01

    Estimations suggest that about 60% of all cancer patients will require some form of radiation therapy during their lifetime. Although 40 to 50% of cancer patients in Europe and the United States receive radiation therapy, only about 20% of patients with cancer in Japan undergo such treatment. This is largely due to the lack of understanding of the role of radiation therapy by many medical personnel in Japan, as well as to ''''radiation allergy'''' among many of the general population in Japan, a country that has been undergone atomic bombing. From our perspective as specialists in radiation therapy, the chronic shortage of radiation oncologist also poses a serious problem. Although there are approximately 700 hospitals throughout Japan where radiation therapy is available, no more than half this number of medical facilities have a full-time radiation oncologist. Perhaps the reason for this is that radiation therapy is perceived as unnecessary in Japan. However, it is absolutely essential. In our experience, the 5-year relative survival rate of patients with malignant tumors who have undergone radiation therapy in our clinic is 65 percent. Thus, radiation therapy has proven very useful in the treatment of malignant tumors. Moreover, better estimates of prognosis of cancer patients treated with radiation therapy are becoming possible. This article discusses the role of radiation therapy, from a radiation pathological perspective, in a multidisciplinary approach to treatment of cancer patients. I also emphasize the critical importance of training radiation oncologists who can function as part of multidisciplinary teams that care for patients with malignant tumors. (author). 50 refs

  10. Auger radiation targeted into DNA: a therapy perspective

    Energy Technology Data Exchange (ETDEWEB)

    Buchegger, Franz [University Hospital of Lausanne CHUV, Service of Nuclear Medicine, Lausanne (Switzerland); University Hospital of Lausanne, Service of Nuclear Medicine, Lausanne (Switzerland); Perillo-Adamer, Florence; Bischof Delaloye, Angelika [University Hospital of Lausanne CHUV, Service of Nuclear Medicine, Lausanne (Switzerland); Dupertuis, Yves M. [University Hospital of Geneva, Service of Nutrition, Geneva (Switzerland)

    2006-11-15

    Auger electron emitters that can be targeted into DNA of tumour cells represent an attractive systemic radiation therapy goal. In the situation of DNA-associated decay, the high linear energy transfer (LET) of Auger electrons gives a high relative biological efficacy similar to that of {alpha} particles. In contrast to {alpha} radiation, however, Auger radiation is of low toxicity when decaying outside the cell nucleus, as in cytoplasm or outside cells during blood transport. The challenge for such therapies is the requirement to target a high percentage of all cancer cells. An overview of Auger radiation therapy approaches of the past decade shows several research directions and various targeting vehicles. The latter include hormones, peptides, halogenated nucleotides, oligonucleotides and internalising antibodies. Here, we will discuss the basic principles of Auger electron therapy as compared with vector-guided {alpha} and {beta} radiation. We also review some radioprotection issues and briefly present the main advantages and disadvantages of the different targeting modalities that are under investigation. (orig.)

  11. Auger radiation targeted into DNA: a therapy perspective

    International Nuclear Information System (INIS)

    Buchegger, Franz; Perillo-Adamer, Florence; Bischof Delaloye, Angelika; Dupertuis, Yves M.

    2006-01-01

    Auger electron emitters that can be targeted into DNA of tumour cells represent an attractive systemic radiation therapy goal. In the situation of DNA-associated decay, the high linear energy transfer (LET) of Auger electrons gives a high relative biological efficacy similar to that of α particles. In contrast to α radiation, however, Auger radiation is of low toxicity when decaying outside the cell nucleus, as in cytoplasm or outside cells during blood transport. The challenge for such therapies is the requirement to target a high percentage of all cancer cells. An overview of Auger radiation therapy approaches of the past decade shows several research directions and various targeting vehicles. The latter include hormones, peptides, halogenated nucleotides, oligonucleotides and internalising antibodies. Here, we will discuss the basic principles of Auger electron therapy as compared with vector-guided α and β radiation. We also review some radioprotection issues and briefly present the main advantages and disadvantages of the different targeting modalities that are under investigation. (orig.)

  12. Breast conservation therapy for breast cancer. Radiation oncologist's point of view

    International Nuclear Information System (INIS)

    Hiraoka, Masahiro; Mitsumori, Michihide; Kokubo, Masaki; Fujishiro, Satsuki

    1998-01-01

    The roles and problems of radiation therapy in breast conserving therapy for breast cancer were presented. The roles of radiation therapy include decrease in breast recurrence, an alternative to axillary dissection for N0 cases, and neo-adjuvant radiation therapy. On the other hand, problems associated with radiation therapy are question of using radiation therapy for all cases, complications and worsening of cosmetics, and relatively high breast recurrence rates for margin-positive cases. The concept of breast conserving therapy is to improve QOL without decreasing treatment outcomes. It is considered that we should be more concentrated on the aspects of QOL because treatment outcomes of breast conserving therapy in Japan demonstrated sofar appear excellent. (author)

  13. Missed Radiation Therapy and Cancer Recurrence

    Science.gov (United States)

    Patients who miss radiation therapy sessions during cancer treatment have an increased risk of their disease returning, even if they eventually complete their course of radiation treatment, according to a new study.

  14. 21 CFR 892.5050 - Medical charged-particle radiation therapy system.

    Science.gov (United States)

    2010-04-01

    ...-particle radiation therapy system. (a) Identification. A medical charged-particle radiation therapy system... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical charged-particle radiation therapy system... equipment, patient and equipment supports, treatment planning computer programs, component parts, and...

  15. A dosimetric comparison of 3D-CRT, IMRT, and static tomotherapy with an SIB for large and small breast volumes

    Energy Technology Data Exchange (ETDEWEB)

    Michalski, Andrea [Department of Health Science (MRS), The University of Sydney, Lidcombe, New South Wales (Australia); Central Coast Cancer Centre, Gosford Hospital, Gosford, New South Wales (Australia); Atyeo, John, E-mail: john.atyeo@sydney.edu.au [Department of Health Science (MRS), The University of Sydney, Lidcombe, New South Wales (Australia); Cox, Jennifer [Department of Health Science (MRS), The University of Sydney, Lidcombe, New South Wales (Australia); Department of Radiation Oncology, Royal North Shore Hospital, St Leonards, New South Wales (Australia); Rinks, Marianne [Department of Health Science (MRS), The University of Sydney, Lidcombe, New South Wales (Australia); Radiation Oncology, Cancer Services, Illawarra Shoalhaven Local Health District, Wollongong, New South Wales (Australia); Morgia, Marita; Lamoury, Gillian [Department of Radiation Oncology, Royal North Shore Hospital, St Leonards, New South Wales (Australia)

    2014-07-01

    Radiation therapy to the breast is a complex task, with many different techniques that can be employed to ensure adequate dose target coverage while minimizing doses to the organs at risk. This study compares the dose planning outcomes of 3 radiation treatment modalities, 3 dimensional conformal radiation therapy (3D-CRT), intensity-modulated radiation therapy (IMRT), and static tomotherapy, for left-sided whole-breast radiation treatment with a simultaneous integrated boost (SIB). Overall, 20 patients with left-sided breast cancer were separated into 2 cohorts, small and large, based on breast volume. Dose plans were produced for each patient using 3D-CRT, IMRT, and static tomotherapy. All patients were prescribed a dose of 45 Gy in 20 fractions to the breast with an SIB of 56 Gy in 20 fractions to the tumor bed and normalized so that D{sub 98%} > 95% of the prescription dose. Dosimetric comparisons were made between the 3 modalities and the interaction of patient size. All 3 modalities offered adequate planning target volume (PTV) coverage with D{sub 98%} > 95% and D{sub 2%} < 107%. Static tomotherapy offered significantly improved (p = 0.006) dose homogeneity to the PTV{sub boost} {sub eval} (0.079 ± 0.011) and breast minus the SIB volume (Breast{sub SIB}) (p < 0.001, 0.15 ± 0.03) compared with the PTV{sub boost} {sub eval} (0.085 ± 0.008, 0.088 ± 0.12) and Breast{sub SIB} (0.22 ± 0.05, 0.23 ± 0.03) for IMRT and 3D-CRT, respectively. Static tomotherapy also offered statistically significant reductions (p < 0.001) in doses to the ipsilateral lung mean dose of 6.79 ± 2.11 Gy compared with 7.75 ± 2.54 Gy and 8.29 ± 2.76 Gy for IMRT and 3D-CRT, respectively, and significantly (p < 0.001) reduced heart doses (mean = 2.83 ± 1.26 Gy) compared to both IMRT and 3D-CRT (mean = 3.70 ± 1.44 Gy and 3.91 ± 1.58 Gy). Static tomotherapy is the dosimetrically superior modality for the whole breast with an SIB compared with IMRT and 3D-CRT. IMRT is superior to 3D

  16. SU-F-P-08: Medical Physics Perspective On Radiation Therapy Quality and Safety Considerations in Low Income Settings

    Energy Technology Data Exchange (ETDEWEB)

    Van Dyk, J [Western University London, ON (Canada); Meghzifene, A [International Atomic Energy Agency, Vienna (Austria)

    2016-06-15

    Purpose: The last few years have seen a significant growth of interest in the global radiation therapy crisis. Various organizations are quantifying the need and providing aid in support of addressing the shortfall existing in many low-to-middle income countries (LMICs). The Lancet Oncology Commission report (Lancet Oncol. Sep;16(10):1153-86, 2015) projects a need of 22,000 new medical physicists in LMICs by 2035 if there is to be equal access globally. With the tremendous demand for new facilities, equipment and personnel, it is very important to recognize quality and safety considerations and to address them directly. Methods: A detailed examination of quality and safety publications was undertaken. A paper by Dunscombe (Front. Oncol. 2: 129, 2012) reviewed the recommendations of 7 authoritative reports on safety in radiation therapy and found the 12 most cited recommendations, summarized in order of most to least cited: training, staffing, documentation/standard operating procedures, incident learning, communication/questioning, check lists, QC/PM, dosimetric audit, accreditation, minimizing interruptions, prospective risk assessment, and safety culture. However, these authoritative reports were generally based on input from high income contexts. In this work, the recommendations were analyzed with a special emphasis on issues that are significant in LMICs. Results: The review indicated that there are significant challenges in LMICs with training and staffing ranking at the top in terms quality and safety. Conclusion: With the recognized need for expanding global access to radiation therapy, especially in LMICs, and the backing by multiple support organizations, quality and safety considerations must be overtly addressed. While multidimensional, training and staffing are top priorities. The use of outdated systems with poor interconnectivity, coupled with a lack of systematic QA in high patient load settings are additional concerns. Any support provided to lower

  17. SU-F-P-08: Medical Physics Perspective On Radiation Therapy Quality and Safety Considerations in Low Income Settings

    International Nuclear Information System (INIS)

    Van Dyk, J; Meghzifene, A

    2016-01-01

    Purpose: The last few years have seen a significant growth of interest in the global radiation therapy crisis. Various organizations are quantifying the need and providing aid in support of addressing the shortfall existing in many low-to-middle income countries (LMICs). The Lancet Oncology Commission report (Lancet Oncol. Sep;16(10):1153-86, 2015) projects a need of 22,000 new medical physicists in LMICs by 2035 if there is to be equal access globally. With the tremendous demand for new facilities, equipment and personnel, it is very important to recognize quality and safety considerations and to address them directly. Methods: A detailed examination of quality and safety publications was undertaken. A paper by Dunscombe (Front. Oncol. 2: 129, 2012) reviewed the recommendations of 7 authoritative reports on safety in radiation therapy and found the 12 most cited recommendations, summarized in order of most to least cited: training, staffing, documentation/standard operating procedures, incident learning, communication/questioning, check lists, QC/PM, dosimetric audit, accreditation, minimizing interruptions, prospective risk assessment, and safety culture. However, these authoritative reports were generally based on input from high income contexts. In this work, the recommendations were analyzed with a special emphasis on issues that are significant in LMICs. Results: The review indicated that there are significant challenges in LMICs with training and staffing ranking at the top in terms quality and safety. Conclusion: With the recognized need for expanding global access to radiation therapy, especially in LMICs, and the backing by multiple support organizations, quality and safety considerations must be overtly addressed. While multidimensional, training and staffing are top priorities. The use of outdated systems with poor interconnectivity, coupled with a lack of systematic QA in high patient load settings are additional concerns. Any support provided to lower

  18. Adjuvant and Salvage Radiation Therapy After Prostatectomy: American Society for Radiation Oncology/American Urological Association Guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Valicenti, Richard K., E-mail: Richard.valicenti@ucdmc.ucdavis.edu [Department of Radiation Oncology, University of California, Davis School of Medicine, Davis, California (United States); Thompson, Ian [Department of Urology, University of Texas Health Science Center at San Antonio, San Antonio, Texas (United States); Albertsen, Peter [Division of Urology, University of Connecticut Health Center, Farmington, Connecticut (United States); Davis, Brian J. [Department of Radiation Oncology, Mayo Medical School, Rochester, Minnesota (United States); Goldenberg, S. Larry [Department of Urologic Sciences, University of British Columbia, Vancouver, British Columbia (Canada); Wolf, J. Stuart [Department of Urology, University of Michigan, Ann Arbor, Michigan (United States); Sartor, Oliver [Department of Medicine and Urology, Tulane Medical School, New Orleans, Louisiana (United States); Klein, Eric [Glickman Urological Kidney Institute, Cleveland Clinic, Cleveland, Ohio (United States); Hahn, Carol [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States); Michalski, Jeff [Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri (United States); Roach, Mack [Department of Radiation Oncology, University of California, San Francisco, San Francisco, California (United States); Faraday, Martha M. [Four Oaks, Inc (United States)

    2013-08-01

    Purpose: The purpose of this guideline was to provide a clinical framework for the use of radiation therapy after radical prostatectomy as adjuvant or salvage therapy. Methods and Materials: A systematic literature review using PubMed, Embase, and Cochrane database was conducted to identify peer-reviewed publications relevant to the use of radiation therapy after prostatectomy. The review yielded 294 articles; these publications were used to create the evidence-based guideline statements. Additional guidance is provided as Clinical Principles when insufficient evidence existed. Results: Guideline statements are provided for patient counseling, use of radiation therapy in the adjuvant and salvage contexts, defining biochemical recurrence, and conducting a restaging evaluation. Conclusions: Physicians should offer adjuvant radiation therapy to patients with adverse pathologic findings at prostatectomy (ie, seminal vesicle invastion, positive surgical margins, extraprostatic extension) and salvage radiation therapy to patients with prostate-specific antigen (PSA) or local recurrence after prostatectomy in whom there is no evidence of distant metastatic disease. The offer of radiation therapy should be made in the context of a thoughtful discussion of possible short- and long-term side effects of radiation therapy as well as the potential benefits of preventing recurrence. The decision to administer radiation therapy should be made by the patient and the multidisciplinary treatment team with full consideration of the patient's history, values, preferences, quality of life, and functional status. The American Society for Radiation Oncology and American Urological Association websites show this guideline in its entirety, including the full literature review.

  19. Adjuvant and Salvage Radiation Therapy After Prostatectomy: American Society for Radiation Oncology/American Urological Association Guidelines

    International Nuclear Information System (INIS)

    Valicenti, Richard K.; Thompson, Ian; Albertsen, Peter; Davis, Brian J.; Goldenberg, S. Larry; Wolf, J. Stuart; Sartor, Oliver; Klein, Eric; Hahn, Carol; Michalski, Jeff; Roach, Mack; Faraday, Martha M.

    2013-01-01

    Purpose: The purpose of this guideline was to provide a clinical framework for the use of radiation therapy after radical prostatectomy as adjuvant or salvage therapy. Methods and Materials: A systematic literature review using PubMed, Embase, and Cochrane database was conducted to identify peer-reviewed publications relevant to the use of radiation therapy after prostatectomy. The review yielded 294 articles; these publications were used to create the evidence-based guideline statements. Additional guidance is provided as Clinical Principles when insufficient evidence existed. Results: Guideline statements are provided for patient counseling, use of radiation therapy in the adjuvant and salvage contexts, defining biochemical recurrence, and conducting a restaging evaluation. Conclusions: Physicians should offer adjuvant radiation therapy to patients with adverse pathologic findings at prostatectomy (ie, seminal vesicle invastion, positive surgical margins, extraprostatic extension) and salvage radiation therapy to patients with prostate-specific antigen (PSA) or local recurrence after prostatectomy in whom there is no evidence of distant metastatic disease. The offer of radiation therapy should be made in the context of a thoughtful discussion of possible short- and long-term side effects of radiation therapy as well as the potential benefits of preventing recurrence. The decision to administer radiation therapy should be made by the patient and the multidisciplinary treatment team with full consideration of the patient's history, values, preferences, quality of life, and functional status. The American Society for Radiation Oncology and American Urological Association websites show this guideline in its entirety, including the full literature review

  20. Improving Outcomes for Esophageal Cancer using Proton Beam Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Chuong, Michael D. [Department of Radiation Oncology, University of Maryland Medical Center, Baltimore, Maryland (United States); Hallemeier, Christopher L. [Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota (United States); Jabbour, Salma K. [Department of Radiation Oncology, Rutgers Cancer Institute of New Jersey, New Brunswick, New Jersey (United States); Yu, Jen; Badiyan, Shahed [Department of Radiation Oncology, University of Maryland Medical Center, Baltimore, Maryland (United States); Merrell, Kenneth W. [Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota (United States); Mishra, Mark V. [Department of Radiation Oncology, University of Maryland Medical Center, Baltimore, Maryland (United States); Li, Heng [Department of Radiation Oncology, The University of Texas M. D. Anderson Cancer Center, Houston, Texas (United States); Verma, Vivek [Department of Radiation Oncology, University of Nebraska Medical Center, Omaha, Nebraska (United States); Lin, Steven H., E-mail: shlin@mdanderson.org [Department of Radiation Oncology, The University of Texas M. D. Anderson Cancer Center, Houston, Texas (United States)

    2016-05-01

    Radiation therapy (RT) plays an essential role in the management of esophageal cancer. Because the esophagus is a centrally located thoracic structure there is a need to balance the delivery of appropriately high dose to the target while minimizing dose to nearby critical structures. Radiation dose received by these critical structures, especially the heart and lungs, may lead to clinically significant toxicities, including pneumonitis, pericarditis, and myocardial infarction. Although technological advancements in photon RT delivery like intensity modulated RT have decreased the risk of such toxicities, a growing body of evidence indicates that further risk reductions are achieved with proton beam therapy (PBT). Herein we review the published dosimetric and clinical PBT literature for esophageal cancer, including motion management considerations, the potential for reirradiation, radiation dose escalation, and ongoing esophageal PBT clinical trials. We also consider the potential cost-effectiveness of PBT relative to photon RT.