WorldWideScience

Sample records for radiation respuesta tl

  1. Tl response of KMgF{sub 3}: Lu + PTFE at ultraviolet radiation; Respuesta Tl de KMgF{sub 3}: Lu + PTFE a radiacion ultravioleta

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, P R [Instituto Nacional de Investigaciones Nucleares, A.P. 18 -1027, 11801 Mexico D.F. (Mexico); Alarcon, N G [Facultad de Quimica, Universidad Autonoma del Estado de Mexico. Paseo Tollocan, Esq. con Jesus Carranza, 50180 Toluca, Estado de Mexico (Mexico); Furetta, C; Azorin, J [Universidad Autonoma Metropolitana- Iztapalapa, San Rafael Atlixco 186, 09340 Mexico. D.F. (Mexico)

    2003-07-01

    Ionizing radiation has different types of interaction with a crystalline solid. However, only few effects are interesting to optimize some thermoluminescent (Tl) properties of certain Tl materials. This paper presents results obtained by irradiating KMgF{sub 3}: Lu + Ptfe Tl dosimeters with ultraviolet (UV) radiation previously exposed to gamma radiation. These results showed that those dosimeters not exposed previously to gamma radiation did not presented any Tl signal. Meanwhile, those previously submitted to gamma irradiation showed that their sensitivity was increased as the gamma dose increased. The glow curve of sensitized KMgF{sub 3}: Lu + Ptfe exposed to UV radiation, presented the dosimetric pea at 212 C. This makes this material to be promissory for measuring UV radiation. (Author)

  2. Tl response of KMgF3: Lu + PTFE at ultraviolet radiation

    International Nuclear Information System (INIS)

    Gonzalez, P.R.; Alarcon, N.G.; Furetta, C.; Azorin, J.

    2003-01-01

    Ionizing radiation has different types of interaction with a crystalline solid. However, only few effects are interesting to optimize some thermoluminescent (Tl) properties of certain Tl materials. This paper presents results obtained by irradiating KMgF 3 : Lu + Ptfe Tl dosimeters with ultraviolet (UV) radiation previously exposed to gamma radiation. These results showed that those dosimeters not exposed previously to gamma radiation did not presented any Tl signal. Meanwhile, those previously submitted to gamma irradiation showed that their sensitivity was increased as the gamma dose increased. The glow curve of sensitized KMgF 3 : Lu + Ptfe exposed to UV radiation, presented the dosimetric pea at 212 C. This makes this material to be promissory for measuring UV radiation. (Author)

  3. Experimental studies on radiation damages of CsI(Tl) crystals

    International Nuclear Information System (INIS)

    He Jingtang; Mao Yufang; Dong Xiaoli; Chen Duanbao; Li Zuhao

    1997-01-01

    The results of experimental studies on radiation damage of CsI(Tl) crystal were reported. There are radiation damage effects on CsI(Tl) crystal. Experimental studies on recovery of damaged CsI(Tl) crystals were made. It seems that after heating at 200 degree C for 4 hours, the damaged crystals could be recovered completely

  4. Tl-201 and Tc-99m-DTPA neuro-SPECT in cerebral radiation necrosis

    International Nuclear Information System (INIS)

    Cleto, E.M. Jr.; Holmes, R.A.; Gumerlock, M.K.; Cabeen, M.; Logan, K.W.; Hoffman, T.J.

    1992-01-01

    The results in 3 cases of radiation necrosis demonstrate that by using both radionuclides Tl-201 and Tc-99m-DTPA, one can provide a semi-quantitative method to differentiate recurrent tumor from radiation necrosis. Focally increased cerebral Tl-201 activity in irradiated brain tumor patients is not specific for tumor recurrence, but when used in combination with DTPA, one is able to estimate the amount of Tl-201 activity resulting from increased blood-brain barrier permeability. If the average Tl-201 index is less than the average Tc-99m-DTPA index it suggests that the increased Tl-201 activity results primarily from blood-brain barrier breakdown. Tc-99m-DTPA SPECT, in addition to Tl-201 SPECT, or serial Tl-201 SPECT imaging may increase the accuracy of brain scintigraphy in differentiating radiation necrosis from tumor recurrence. To verify these preliminary findings, we are in the process of analyzing additional SPECT data on 9 more patients with malignant brain tumors. Using a slightly different method of quantifying Tl- 201/Tc-99m-DTPA ratios (computing the ratio of intralesional Tl-201 or Tc-99m-DTPA activity compared to adjacent scalp activity), patients with tumor recurrence have higher Tl-201/Tc-99m-DTPA ratios compared to those with radiation necrosis (verbal communication with Dr. Mary K. Gumerlock). (orig.) [de

  5. Experience with TL-102M for the treatment of radiation stomatitis

    International Nuclear Information System (INIS)

    Nishio, Juntaro; Matsuya, Tokuzo; Inoue, Kazuo; Miyazaki, Tadashi; Maeda, Noriaki.

    1984-01-01

    TL-102M was administered to 14 patients who had radiation stomatitis following radiation therapy for malignant tumors in the oral cavity. Regarding the degree of overall improvement, one of the 14 patients was evaluated as ''extremely improved'', eight as ''improved'', four as ''slightly improved'', and one as ''unchanged''. None of the patients had side effects. Adherent, powdered TL-102M was easy to take for patients. Most of the patients desired to continue to take this drug because of having neither painfulness nor adhesive feeling. The usage of TL-102M could be helpful in promoting the treatment for cancer, thus suggesting that it is useful in treating radiation stomatitis. (Namekawa, K.)

  6. Radiation Hardness Study of CsI(Tl) Crystals for Belle II Calorimeter

    CERN Document Server

    Matvienko, D V; Sedov, E V; Shwartz, B A

    2017-01-01

    The Belle II calorimeter (at least, its barrel part) consists of CsI(Tl) scintillation crystals which have been used at the Belle experiment. We perform the radiation hardness study of some typical Belle crystals and conclude their light output reductions are acceptable for Belle II experiment where the absorption dose can reach 10 krad during the detector operation. CsI(Tl) crystals have high stablity and low maintenance cost and are considered as possible option for the calorimeter of the future Super-Charm-Tau factory (SCT) in Novosibirsk. Our study demonstrates sufficiently high radiation hardness of CsI(Tl) crystals for SCT conditions.

  7. Radiation exposure around patients after 201Tl-myocardial scintigraphy

    International Nuclear Information System (INIS)

    Kurtaran, A.; Preitfellner, J.; Kohoutek, D.; Tousek, A.; Virgolini, I.; Havlik, E.

    1997-01-01

    Aim: It was the aim of the study to assess the additional radiation exposure to patients, attendents and nurses by patients who are undergoing nuclear medicine investigations (myocardial scintigraphy) with 201 Tl-chloride ( 201 Tl-Cl). Methode: In 16 cases the dose rates at 0.5, 1 and 2 m distance from patients were measured at 0.5, 1.5, 3-4 and 24, in some cases until 370 h after administration of 100±10 MBq 201 Tl-Cl. From the time courses of the dose rates around the patients the possible radiation exposure of other persons were estimated. Results: The initial values of the dose rate were 3.82 μSv/h at 0.5 m, 1.18 μSv/h at 1 m and 0.30 μSv/h at 2 m distance from the patients respectively. The dose rates were decreasing following a monoexponential course with an effective half-life of 60 h. The maximum doses to other persons at 1 m distance from the patients were determined by considering three scenarios. The values were 13 μSv in the waiting room, 26 μSv for nurses working in the ward and 105 μSv for persons living in the same household. Conclusion: Even at very restrictive assumptions the doses were far below the maximum permissible dose to non-radiation workers set by radiation protection regulations (1.5 mSv per year). (orig.) [de

  8. TL and OSL dosimetric properties of Opal gemstone for gamma radiation dosimetry

    International Nuclear Information System (INIS)

    Antonio, Patrícia L.; Gronchi, Claudia C.; Oliveira, Raquel A.P.; Khoury, Helen J.; Caldas, Linda V.E.

    2016-01-01

    In this work, the response of the natural material Opal was studied in relation to its thermoluminescence (TL) and optically stimulated luminescence (OSL), after exposure to the gamma radiation of a "6"0Co source. The structure of the powdered Opal was verified using the X-ray diffraction, scanning electronic microscopy and energy-dispersive X-ray spectroscopy techniques. The material, in its stone form, was turned into powder and mixed to Teflon (also in powder) in three different concentrations, and then pellets were manufactured. The aim of this work was to evaluate the response of these pellets in high-doses of gamma radiation beams, and to observe their possible application as dosimeters, using the TL and OSL techniques. The dosimetric properties of the samples were analyzed by means of different tests, as: TL emission curves and OSL signal decay curves, reproducibility of TL and OSL response, minimum detectable dose, TL and OSL dose–response curves (5 Gy–10 kGy), and fading. The results obtained in this work, for the TL and OSL phenomena, demonstrated that the pellets of Opal + Teflon present an adequate performance e possibility of use as dosimeters in beams of high-dose gamma radiation. - Highlights: • The XRD, SEM and EDX techniques were used to investigate powdered Opal. • Pellets of three different concentrations of Opal and Teflon were studied. • The dosimetric properties of the Opal + Teflon pellets were verified. • TL and OSL techniques were used to analyze the characteristics of the pellets. • Pellets of concentration of 2:1 (Opal:Teflon) presented the most adequate results.

  9. Gamma-radiation-induced change in the activation energy of TL traps in LiRbSO[sub 4]:Tl

    Energy Technology Data Exchange (ETDEWEB)

    Kassem, M.E.; El-Kolaly, M.A.; Al-Houty, L.I. (Qatar Univ., Doha (Qatar). Dept. of Physics)

    1994-06-01

    Thermoluminescence (TL) measurements were carried out for pure and doped LiRbSO[sub 4], with different concentrations of thallium (Tl). The glow-curve range of measurement is between room temperature up to 300[sup o]C. The radiation absorbed dose is in the range 56-3.2 x 10[sup 5] Gy. The results show that both pure and doped samples have glow peak temperatures that are dose dependent, and vary between 70-80[sup o]C and 140-170[sup o]C for pure and doped samples respectively. Doped samples display double peaks that increase with dopant concentration up to about 0.7% wt. The second peak which occurs at high temperature increases linearly with dose up to 4500 Gy. From the results it is proposed that LiRbSO[sub 4] doped with 0.7% Tl can be used for dosimetric purposes in this range. The activation energies of structural transitions are estimated and the results are discussed on the basis of radiation-induced stable dipoles in the random field system. (Author).

  10. X-ray photoemission analysis of chemically modified TlBr surfaces for improved radiation detectors

    International Nuclear Information System (INIS)

    Nelson, A. J.; Voss, L. F.; Beck, P. R.; Graff, R. T.; Conway, A. M.; Nikolic, R. J.; Payne, S. A.; Lee, J.-S.; Kim, H.; Cirignano, L.; Shah, K.

    2013-01-01

    We subjected device-grade TlBr to various chemical treatments used in room temperature radiation detector fabrication to determine the resulting surface composition and electronic structure. As-polished TlBr was treated separately with HCl, SOCl 2 , Br:MeOH and HF solutions. High-resolution photoemission measurements on the valence band electronic structure and Tl 4f, Br 3d, Cl 2p and S 2p core lines were used to evaluate surface chemistry and shallow heterojunction formation. Surface chemistry and valence band electronic structure were correlated with the goal of optimizing the long-term stability and radiation response

  11. TL and LOE dosimetric evaluation of diamond films exposed to beta and ultraviolet radiation

    International Nuclear Information System (INIS)

    Preciado F, S.; Melendrez, R.; Chernov, V.; Barboza F, M.; Schreck, M.; Cruz Z, E.

    2005-01-01

    The diamond possesses a privileged position regarding other materials of great technological importance. Their applications go from the optics, microelectronics, metals industry, medicine and of course as dosemeter, in the registration and detection of ionizing and non ionizing radiation. In this work the results of TL/LOE obtained in two samples of diamond of 10 μm thickness grown by the chemical vapor deposition method (CVD) assisted by microwave plasma. The films were deposited in a silicon substrate (001) starting from a mixture of gases composed of CH 4 /H 2 and 750 ppm of molecular nitrogen as dopant. The samples were exposed to beta radiation (Sr 90 / Y 90 ) and ultraviolet, being stimulated later on thermal (TL) and optically (LOE) to evaluate their dosimetric properties. The sample without doping presented high response TL/LOE to the ultraviolet and beta radiation. The TL glow curve of the sample without doping showed two TL peaks with second order kinetics in the range of 520 to 550 K, besides a peak with first order kinetics of more intensity around 607 K. The TL efficiency of the non doped sample is bigger than the doped with nitrogen; however the LOE efficiency is similar in both samples. The results indicate that the CVD diamond possesses excellent perspectives for dosimetric applications, with special importance in radiotherapy due to it is biologically compatible with the human tissue. (Author)

  12. Tl response of KMgF3 :Lu+PTFE depending on the dose of gamma radiation of 60Co

    International Nuclear Information System (INIS)

    Lopez, A.; Gonzalez, P.R.; Furetta, C.; Azorin, J; Rivera, T.; Sepulveda, F.

    2002-01-01

    Due to the great interest in Tl dosimetry for measuring the levels of radiation doses, as environmental as in the different medical radiation applications in different laboratories of the World it is continued in the searching of new Tl materials with optimum dosimetric characteristics and low cost. In this work the obtained results when irradiating Tl dosemeters of KMgF 3 :Lu + PTFE with gamma radiation of 60 Co are presented. Such results showed that this material presents linearity of response depending on the dose between 0.016 to 100 Gy. Although it is continued with the characterization tests it is able to say that this Tl new material can be used for dosimetric aims. (Author)

  13. Impact of precursor purity on optical properties and radiation detection of CsI:Tl scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Saengkaew, Phannee; Cheewajaroen, Kulthawat; Yenchai, Chadet; Thong-aram, Decho [Chulalongkorn University, Department of Nuclear Engineering, Faculty of Engineering, Bangkok (Thailand); Sanorpim, Sakuntam [Chulalongkorn University, Department of Physics, Faculty of Science, Bangkok (Thailand); Jitpukdee, Manit [Kasetsart University, Department of Applied Radiation and Isotope, Faculty of Science, Bangkok (Thailand); Yordsri, Visittapong; Thanachayanont, Chanchana [Ministry of Science and Technology, National Metal and Materials Technology Center, National Science and Technology Development Agency, Pathumthani (Thailand); Nuntawong, Noppadon [Ministry of Science and Technology, National Electronic and Computer Technology Center, National Science and Technology Development Agency, Pathumthani (Thailand)

    2016-08-15

    Cesium iodide doped with thallium (CsI:Tl) crystals was grown to develop the gamma-ray detectors by using low-cost raw materials. Effect of impurities on optical properties and radiation detection performance was investigated. By a modified homemade Bridgman-Stockbarger technique, CsI:Tl samples were grown in two levels of CsI and TlI reactant materials, i.e., having as a very high purity of 99.999 % and a high purity of 99.9 %. XRD measurements indicate CsI:Tl crystals having a good quality with a dominant (110) plane. Having a cubic structure, a lattice constant of CsI crystals of 0.4574 nm and a crystallite size of 43.539 nm were obtained. From the lower-purity raw materials, calcite was found in an orange crystal with a lattice constant of 0.4560 nm and a crystallite size of 43.089 nm. By PL measurements, the optical properties of the CsI:Tl crystals were analyzed. ∝540-nm-wavelength PL peak was observed from the colorless high-purity crystal, and ∝600-nm-wavelength PL peak was observed from the orange crystal. The brighter PL emission was obtained from the orange crystals suggesting impurities. CsI:Tl surface morphology by SEM exhibited a smooth surface with some parallel crystal facets. For electrical properties of high-quality CsI:Tl crystals, the electrical resistances were 230 ± 16 MΩ in cross-sectional direction and 714 ± 136 MΩ in vertical direction with respect to more homogeneous crystal quality in cross-sectional direction than that in vertical direction. TEM measurement was applied to evaluate the microstructure of colorless CsI:Tl crystal with different patterns of a cubic structure. Both CsI:Tl crystals show good efficiencies and good resolutions. Maintaining the same electronic conditions and amplifications, the colorless CsI:Tl scintillators represented a higher detection efficiency at 122 keV of Co-57 of 78.4 % and the energy resolution of 23.3 % compared to the detection efficiency of 75.9 % and the energy resolution of 34.6 % of the

  14. Radiation accident dosimetry: TL properties of mobile phone screen glass

    International Nuclear Information System (INIS)

    Bassinet, C.; Pirault, N.; Baumann, M.; Clairand, I.

    2014-01-01

    Mobile phones are carried by a large part of the population and previous studies have shown that they may be able to function as individual fortuitous dosimeters in case of radiological accident. This study deals with thermoluminescence (TL) properties of mobile phone screen glass. The presence of a significant background signal which partially overlaps with the radiation-induced signal is a serious issue for dose reconstruction. A mechanical method to reduce this signal using a diamond grinding bit is presented. An over-response at low energy (∼50 keV) is observed for two investigated glasses. The results of a dose recovery test using a single-aliquot regenerative-dose (SAR) procedure are discussed. - Highlights: • Mobile phone screen glass is a promising material for retrospective dosimetry. • The TL non-radiation induced background signal can be significantly reduced by a mechanical method. • A dose recovery test using an SAR procedure was successfully carried out for the investigated glass

  15. Non-radiation induced signals in TL dosimetry

    International Nuclear Information System (INIS)

    German, U.; Weinstein, M.

    2002-01-01

    One source of background signals, which are non-radiation related, is the reader system and it includes dark current, external contaminants and electronic spikes. These factors can induce signals equivalent to several hundredths of mSv. Mostly, the effects are minimised by proper design of the TLD reader, but some effects are dependent on proper operation of the system. The other main group of background signals originate in the TL crystal and is due to tribothermoluminescence, dirt, chemical reactions and stimulation by visible or UV light. These factors can have a significant contribution, equivalent to over several mSv, depending on whether the crystal is bare or protected by PTFE. Working in clean environments, monitoring continuously the glow curve and performing glow curve deconvolution are suggested to minimise non-radiation induced spurious signals. (author)

  16. Influence of deep traps in the Tl response of ZrO{sub 2} + PTFE; Influencia de las trampas profundas en la respuesta Tl de ZrO{sub 2} + PTFE

    Energy Technology Data Exchange (ETDEWEB)

    Rivera M, T.; Azorin N, J.; Falcony G, C.; Martinez S, E.; Garcia H, M. [Universidad Autonoma Metropolitana-Iztapalapa, 09340 Mexico D.F. (Mexico)

    2000-07-01

    In this work are presented the results from investigating the processes related with the defects produced by ionizing radiation in ZrO{sub 2}. It is established an hypothesis which pretends to explain the phenomena that implicates the manifestation of Tl peaks in the brightness curve due to electron removal from the surface traps to the deep traps, through the thermo-transference process, where the excitonic process correspond to the F centers. During the experimental process it was observed this effect through the peaks running in Tl curve. These peaks are presented at 220 and 360 Centigrade for the material without any previous thermal treatment; while that in the samples thermally treated at 100 Centigrade during 1 minute it is observed a slipping in the first peak from 220 to 280 Centigrade, while the second stays in 360 Centigrade. (Author)

  17. TL and LOE dosimetric evaluation of diamond films exposed to beta and ultraviolet radiation; Evaluacion dosimetrica TL y LOE de peliculas de diamante expuestas a radiacion beta y ultravioleta

    Energy Technology Data Exchange (ETDEWEB)

    Preciado F, S.; Melendrez, R.; Chernov, V.; Barboza F, M. [Universidad de Sonora, A.P. 13 y A.P. 5-088, 83000 Hermosillo, Sonora (Mexico); Schreck, M. [Universitaet Augsburg, Institut fuer Physik D-86135 (Germany); Cruz Z, E. [ICN, UNAM, 04500 Mexico D.F. (Mexico)

    2005-07-01

    The diamond possesses a privileged position regarding other materials of great technological importance. Their applications go from the optics, microelectronics, metals industry, medicine and of course as dosemeter, in the registration and detection of ionizing and non ionizing radiation. In this work the results of TL/LOE obtained in two samples of diamond of 10 {mu}m thickness grown by the chemical vapor deposition method (CVD) assisted by microwave plasma. The films were deposited in a silicon substrate (001) starting from a mixture of gases composed of CH{sub 4}/H{sub 2} and 750 ppm of molecular nitrogen as dopant. The samples were exposed to beta radiation (Sr{sup 90}/ Y{sup 90}) and ultraviolet, being stimulated later on thermal (TL) and optically (LOE) to evaluate their dosimetric properties. The sample without doping presented high response TL/LOE to the ultraviolet and beta radiation. The TL glow curve of the sample without doping showed two TL peaks with second order kinetics in the range of 520 to 550 K, besides a peak with first order kinetics of more intensity around 607 K. The TL efficiency of the non doped sample is bigger than the doped with nitrogen; however the LOE efficiency is similar in both samples. The results indicate that the CVD diamond possesses excellent perspectives for dosimetric applications, with special importance in radiotherapy due to it is biologically compatible with the human tissue. (Author)

  18. Importance of the effective atomic number (Zeff) of TL materials for radiation dosimetry in clinical applications

    International Nuclear Information System (INIS)

    Gonzalez M, P.R.

    2008-01-01

    The electric power generation, it has been one of the radiation applications of bigger weight, mainly in developed countries. Another sector of more impact is without a doubt that of the medicine. However, for a sure operation with radiations, those international organisms of radiological safety, exist every time more precise detection systems. The thermoluminescent dosimetry is one of the more reliable methods for this purpose, for that several groups of investigators from different parts of the world, they have guided its investigations in the development of new TL materials. However, to avoid underestimate or overestimation of the measured dose with the use of these materials, it should take into account it effective atomic number (Z eff ) it is well known that some TL materials considered as equivalent to the tissue, presents smaller TL intensity when being irradiated with low energy photons, while the TL material known as not equivalent to the tissue, they present the supra sensitivity effect for this radiation type. Nowadays, the estimate of the Z eff has not been clear, in this work the Z eff is determined by means of the traditional methods and an own method is presented for its determination. The results of the TL signal of different materials, when being irradiated with photons of effective energy between 24 keV and 1.25 MeV and their relationship with their calculated Z eff are also presented. (Author)

  19. Time of gamma radiation transport in NaI(Tl) scintillators

    International Nuclear Information System (INIS)

    Matarrita, A.S.

    1976-01-01

    The distribution of time intervals in function of the energy, ocurred between the incidence of a gamma radiation in the face of a scintillation crystal and the arrival of the correspondent scintillation at photocathode, is calculated. The mean square fluctuation these time interval, relating to resolution of the detector system is determined. The calculations are done for NaI (Tl) cylindrical crystals with the radiation source placed in the symmetry axis, in two situations: para axial incidence and oblique incidence, indicating a good agreement with experimental data. (M.C.K.) [pt

  20. Influence of Impurities on the Radiation Response of the TlBr Semiconductor Crystal

    Directory of Open Access Journals (Sweden)

    Robinson Alves dos Santos

    2017-01-01

    Full Text Available Two commercially available TlBr salts were used as the raw material for crystal growths to be used as radiation detectors. Previously, TlBr salts were purified once, twice, and three times by the repeated Bridgman method. The purification efficiency was evaluated by inductively coupled plasma mass spectroscopy (ICP-MS, after each purification process. A compartmental model was proposed to fit the impurity concentration as a function of the repetition number of the Bridgman growths, as well as determine the segregation coefficients of impurities in the crystals. The crystalline structure, the stoichiometry, and the surface morphology of the crystals were evaluated, systematically, for the crystals grown with different purification numbers. To evaluate the crystal as a radiation semiconductor detector, measurements of its resistivity and gamma-ray spectroscopy were carried out, using 241Am and 133Ba sources. A significant improvement of the radiation response was observed in function of the crystal purity.

  1. Absorbed radiation to the nuclear medicine nurses from patients administered 201Tl and 99mTc- MIBI

    International Nuclear Information System (INIS)

    Sattari, Ali; Dadashzadeh, Simin; Nasiroghli, G.; Firoozabadi, Hasan

    2008-01-01

    People who have administrated radiopharmaceuticals could be a source of radiation to their relatives, medical nurses, and people who have contact them. In this study, the dose rates at various distances of 5, 10,50 and 100 cm from 70 patients, who were administered diagnostic amounts of 201 Tl -Chloride and 99m Tc -MIBI, was measured using an ionization chamber. For determination of external radiation dose to the nurses the radiations in three deferent interval times have measured. The maximum values of external dose rates of 201 Tl and 99m Tc-MIBI were 11.2μSv/h ±2.3 and 43.1μSv/h ±11.9 respectively at 5 cm from the patients. Significant exposure from patients after injection of 99m Tc -MIBI was limited on the day of administration. Departure doses rate of 201 Tl fell gradually so by 3 days after administration was significant. Maximum and average absorbed dose of nuclear medicine staff for one 201 Tl scan was 4.6 and 2.7μSv/h, and for 99m Tc-MIBI was 18.1 and 9.8μSv/h in a working day. (author)

  2. Tl response of LiF: Mg, Cu, P+Ptfe at X rays of 24, 42 and 100 KeV; Respuesta TL de LiF: Mg, Cu, P+Ptfe a rayos X de 24, 42 y 100 KeV

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez M, P.R.; Tovar M, V.M. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Azorin N, J. [UAM-I, 09340 Mexico D.F. (Mexico); Furetta, C. [Universita degli Studi di Roma ' La Sapienza' , Piazzale Aldo Moro 2, 00185 Roma (Italy); Quiroz C, M.C. [Facultad de Medicina, UAEM, 50180 Toluca, Estado de Mexico (Mexico)

    2005-07-01

    In this work the obtained results of the irradiation of thermoluminescent dosemeters (Tl) of LiF: Mg,Cu,P + Ptfe with X rays for the effective radiation energy of 24, 42 and 100 keV, in an interval of Kerma in air in the sinus of the air between 0.05 and 1.0 Gy are presented. The rate of Kerma in air was determined with an ionization chamber PTW-1152, gauged by the Laboratoire Central des Industries Electriques (LCIE). As reference commercial TLD-100 dosemeters was used. The results showed that the studied Tl dosemeters presented a lineal response in the interval of mentioned Kerma. On the other hand the estimated Kerma with the Tl dosemeter in the calibration curves for X rays, were similar to the one measured with the previously gauged ionization chamber. The Tl of LiF: Mg, Cu, P + Ptfe, developed in the ININ, are highly reliable for X-ray dosimetry. (Author)

  3. Performance of novel materials for radiation detection: Tl3AsSe3, TlGaSe2, and Tl4HgI6

    International Nuclear Information System (INIS)

    Kahler, D.; Singh, N.B.; Knuteson, D.J.; Wagner, B.; Berghmans, A.; McLaughlin, S.; King, M.; Schwartz, K.; Suhre, D.; Gotlieb, M.

    2011-01-01

    In this paper we report on the electrical characteristics of three novel ternary compounds, Tl 3 AsSe 3 (TAS), TlGaSe 2 (TGS), and Tl 4 HgI 6 (THI), pertaining to their use as radiation detectors. The details for growth and material characterization are not presented. A semiconductor based gamma ray detector requires a material with high Z, high density, high resistivity, appropriate bandgap (1.5-2 eV), low energy/electron-hole pair, and a high μτ product. CZT is currently the best semiconductor material for room temperature gamma ray spectroscopy; however, it is extremely difficult to produce large volumes of detector grade material, making it expensive and in limited supply. DNDO/DHS began searching for other materials that might perform as well as CZT but be easier to grow and in the end lower the cost. For this purpose, we investigated the above three materials as possible replacements for CZT as gamma ray detectors. The bulk resistivity, I-V curves, X-ray response, and gamma ray response measurements for doped and undoped crystals are presented and discussed. TAS shows good X-ray and gamma ray response, but has poor resistivity, which results in large dark current and poor spectral response. TGS has good resistivity, but shows poor X-ray and gamma ray response. THI has excellent resistivity, shows some X-ray and gamma ray response, and has great potential as a gamma ray detector.

  4. Influence of temperature in TL signal induced by gamma radiation in zircon prepared by sol gel via

    International Nuclear Information System (INIS)

    Salas, P.; Castano, V.M.; Mendoza A, D.; Gonzalez M, P.R.; Rosa C, E. de la

    2000-01-01

    In this work, it was realized a study of the temperature effects in thermoluminescent signal (Tl) induced by gamma radiation in zircon, which was prepared by the sol gel method. According to the obtained results, the zircon thermically treated at 500 C or over is sensitive to radiation. This sensitivity is increased when the temperature in study is augmented, moreover, the Tl spectra form also is modified with the temperature increment. The samples thermically treated at 750 C or over present a linear response in the dose interval 27 to 165 Gy; therefore, such materials result promissories for dosimetric purposes. (Author)

  5. Study of combinations of TL/OSL single dosimeters for mixed high/low ionization density radiation fields

    International Nuclear Information System (INIS)

    Oster, L.; Druzhyna, S.; Orion, I.; Horowitz, Y.S.

    2013-01-01

    In this paper we discuss and compare the potential application of combined OSL/TL measurements using 6 LiF:Mg,Ti (TLD-600 is enriched of isotope 6 Li which has a high cross-section for the reaction with slow neutrons) or 7 LiF:Mg,Ti ( TLD-700 is enriched of 7 Li isotope) and TLD-100 (natural isotopic composition) detectors. The OSL/TL duel readout of LiF:Mg,Ti as an ionization density discriminator avoids some of the difficulties inherent to the various types of discrimination mixed-field passive dosimeters, and in addition has several advantages. The preferential excitation of OSL compared to TL following high ionization density (HID) alpha irradiation, naturally explained via the identification of OSL with the “two-hit” F 2 or F 3 center, whereas the major component of composite TL glow peak 5 is believed to arise from a ''one-hit'' complex defect. This evidence allows near-total discrimination between HID radiation and low-ionization density (LID) radiation. Beta and alpha particle irradiations were carried out with 90 Sr/ 90 Y (∼500 keV average energy) and 241 Am sources (4.7 MeV) respectively and neutron irradiations were carried out at the PTB (Germany) (E n = 5 MeV) and RARAF (Columbia University, USA) (E n = 6 MeV) accelerator facilities. The highest values of the FOM obtained was ∼30 for neutron/gamma discrimination and ∼110 for alpha/gamma discrimination using OSL/TL – peak 5 measurements in TLD-700. -- Highlights: ► The increased response of OSL compared to TL following HID irradiation is observed. ► This evidence is explained via the identification of OSL with the ''two-hit'' F2 centers. ► The potential application of combined OSL/TL in discrimination dosimetry is discussed. ► The values of FOM were 110 for alpha/gamma and 30 for neutron/gamma discrimination

  6. Effects of film thickness on scintillation characteristics of columnar CsI:Tl films exposed to high gamma radiation doses

    Energy Technology Data Exchange (ETDEWEB)

    Shinde, Seema; Singh, S.G.; Sen, S.; Gadkari, S.C., E-mail: gadkari@barc.gov.in

    2016-02-21

    Oriented columnar films of Tl doped CsI (CsI:Tl) of varying thicknesses from 50 µm to 1000 µm have been deposited on silica glass substrates by a thermal evaporation technique. The SEM micrographs confirmed the columnar structure of the film while the powder X-ray diffraction pattern recorded for the films revealed a preferred orientation of the grown columns along the <200> direction. Effects of high energy gamma exposure up to 1000 Gy on luminescence properties of the films were investigated. Results of radio-luminescence, photo-luminescence and scintillation studies on the films are compared with those of a CsI:Tl single crystal with similar thickness. A possible correlation between the film thicknesses and radiation damage in films has been observed. - Highlights: • CsI:Tl films of different thicknesses deposited for γ and α detection. • Pulse-height spectra found to degrade with increasing thickness. • Radiation damage is found more in films than single crystal of comparable thickness. • Detection efficiency increases for γ while it is invariant for α beyond 50 µm.

  7. Effects of film thickness on scintillation characteristics of columnar CsI:Tl films exposed to high gamma radiation doses

    International Nuclear Information System (INIS)

    Shinde, Seema; Singh, S.G.; Sen, S.; Gadkari, S.C.

    2016-01-01

    Oriented columnar films of Tl doped CsI (CsI:Tl) of varying thicknesses from 50 µm to 1000 µm have been deposited on silica glass substrates by a thermal evaporation technique. The SEM micrographs confirmed the columnar structure of the film while the powder X-ray diffraction pattern recorded for the films revealed a preferred orientation of the grown columns along the direction. Effects of high energy gamma exposure up to 1000 Gy on luminescence properties of the films were investigated. Results of radio-luminescence, photo-luminescence and scintillation studies on the films are compared with those of a CsI:Tl single crystal with similar thickness. A possible correlation between the film thicknesses and radiation damage in films has been observed. - Highlights: • CsI:Tl films of different thicknesses deposited for γ and α detection. • Pulse-height spectra found to degrade with increasing thickness. • Radiation damage is found more in films than single crystal of comparable thickness. • Detection efficiency increases for γ while it is invariant for α beyond 50 µm.

  8. Composite detector for mixed radiations based on CsI(Tl) and dispersions of small ZnSe(Te) crystals

    International Nuclear Information System (INIS)

    Ryzhikov, V.; Gal'chinetskii, L.; Katrunov, K.; Lisetskaya, E.; Gavriluk, V.; Zelenskaya, O.; Starzhynskiy, N.; Chernikov, V.

    2005-01-01

    A new large area detector of high-energy X-ray and β-radiation has been designed and studied. A composite material based on small-crystalline ZnSe(Te) was applied onto the wide surface of a light guide. An experimental specimen has been prepared, which showed β-sensitivity C β =5.5cm 2 . The spectrograms of a 90 Sr+ 90 Y β-source obtained with the specimen under study make it possible to evaluate the age of the source by the ratio of low- and high-energy regions of the spectrum. The combined detector (CD) comprises a single crystalline plate of ZnSe(Te) placed onto the output window of a scintillating transparent light guide made of CsI(Tl) in the shape of a truncated pyramid. The CsI(Tl) light guide is used to create an additional channel for detection of γ-radiation, as well as for protecting the photodiode from the penetrating radiation. It is shown that introduction of the light guide does not worsen the energy resolution characteristics of ZnSe(Te). Separate detection of α- and γ-radiation has been achieved under simultaneous excitation by 239 Pu (ZnSe(Te), R α =6%) and 241 Am (CsI(Tl), R γ =20%). The use of selective optical filters allows separation of the peaks of total absorption (p.t.a.) in the case of their superposition

  9. Performance of novel materials for radiation detection: Tl{sub 3}AsSe{sub 3}, TlGaSe{sub 2}, and Tl{sub 4}HgI{sub 6}

    Energy Technology Data Exchange (ETDEWEB)

    Kahler, D., E-mail: david.kahler@ngc.com [Northrop Grumman Corporation, ES-ATL, 1212 Winterson Road, Linthicum, MD 21090 (United States); Singh, N.B.; Knuteson, D.J.; Wagner, B.; Berghmans, A.; McLaughlin, S.; King, M.; Schwartz, K. [Northrop Grumman Corporation, ES-ATL, 1212 Winterson Road, Linthicum, MD 21090 (United States); Suhre, D.; Gotlieb, M. [DRS Scientific, 300 Oak Lake Road, New Kensington, PA 15068 (United States)

    2011-10-01

    In this paper we report on the electrical characteristics of three novel ternary compounds, Tl{sub 3}AsSe{sub 3} (TAS), TlGaSe{sub 2} (TGS), and Tl{sub 4}HgI{sub 6} (THI), pertaining to their use as radiation detectors. The details for growth and material characterization are not presented. A semiconductor based gamma ray detector requires a material with high Z, high density, high resistivity, appropriate bandgap (1.5-2 eV), low energy/electron-hole pair, and a high {mu}{tau} product. CZT is currently the best semiconductor material for room temperature gamma ray spectroscopy; however, it is extremely difficult to produce large volumes of detector grade material, making it expensive and in limited supply. DNDO/DHS began searching for other materials that might perform as well as CZT but be easier to grow and in the end lower the cost. For this purpose, we investigated the above three materials as possible replacements for CZT as gamma ray detectors. The bulk resistivity, I-V curves, X-ray response, and gamma ray response measurements for doped and undoped crystals are presented and discussed. TAS shows good X-ray and gamma ray response, but has poor resistivity, which results in large dark current and poor spectral response. TGS has good resistivity, but shows poor X-ray and gamma ray response. THI has excellent resistivity, shows some X-ray and gamma ray response, and has great potential as a gamma ray detector.

  10. Influence of temperature in TL signal induced by gamma radiation in zircon prepared by sol gel via; Influencia de la temperatura en la senal TL inducida por la radiacion gamma en zirconia preparada via solgel

    Energy Technology Data Exchange (ETDEWEB)

    Salas, P.; Castano, V.M. [Instituto de Fisica, UNAM, Laboratorio Juriquilla, A.P. 1-1010, 76001 Queretaro (Mexico); Mendoza A, D.; Gonzalez M, P.R. [ININ, Mexico, D.F. (Mexico); Rosa C, E. de la [Centro de Investigaciones en Optical, Leon, Gto. (Mexico)

    2000-07-01

    In this work, it was realized a study of the temperature effects in thermoluminescent signal (Tl) induced by gamma radiation in zircon, which was prepared by the sol gel method. According to the obtained results, the zircon thermically treated at 500 C or over is sensitive to radiation. This sensitivity is increased when the temperature in study is augmented, moreover, the Tl spectra form also is modified with the temperature increment. The samples thermically treated at 750 C or over present a linear response in the dose interval 27 to 165 Gy; therefore, such materials result promissories for dosimetric purposes. (Author)

  11. Point Defect Properties of Cd(Zn)Te and TlBr for Room-Temperature Gamma Radiation Detectors

    Science.gov (United States)

    Lordi, Vincenzo

    2013-03-01

    The effects of various crystal defects in CdTe, Cd1-xZnxTe (CZT), and TlBr are critical for their performance as room-temperature gamma radiation detectors. We use predictive first principles theoretical methods to provide fundamental, atomic scale understanding of the defect properties of these materials to enable design of optimal growth and processing conditions, such as doping, annealing, and stoichiometry. Several recent cases will be reviewed, including (i) accurate calculations of the thermodynamic and electronic properties of native point defects and point defect complexes in CdTe and CZT; (ii) the effects of Zn alloying on the native point defect properties of CZT; (iii) point defect diffusion and binding related to Te clustering in Cd(Zn)Te; (iv) the profound effect of native point defects--principally vacancies--on the intrinsic material properties of TlBr, particularly electronic and ionic conductivity; (v) tailored doping of TlBr to independently control the electronic and ionic conductivity; and (vi) the effects of metal impurities on the electronic properties and device performance of TlBr detectors. Prepared by LLNL under Contract DE-AC52-07NA27344 with support from the National Nuclear Security Administration Office of Nonproliferation and Verification Research and Development NA-22.

  12. Characteristics Of Dosimeter TL CaSO4:Dy Glass Capillaries For Environmental Radiation Dose Monitoring

    International Nuclear Information System (INIS)

    Sofyan Hasnel; Yulianti, Helfi; Ramain, Abubakar; Kusumawati, Dyah D.; Suyati

    2000-01-01

    research on the characteristic of dosimeter TL CaSO 4 : Dy glass capillaries for environmental dose radiation have been carried out. The results obtained are uniform response and reproducibility during three cycles consumption with average percentage standard deviation of 7.31 % and 5.45%. The response dose is linear and has a minimum detectable dose of 0.01 mGy, sunshine effect with non-penetrating light capsule of 4.65%, humidity effects is not significant by using non-penetrating light capsule. Radiation dose information during 30 days are fading 25%

  13. Investigation of TL properties of sand collected from sewage sludge as an ''in situ'' dosimeter in radiation disinfection

    International Nuclear Information System (INIS)

    Benny, P.G.; Bhatt, B.C.

    1996-01-01

    Thermoluminescence (TL) properties of sand, collected from sewage sludge, were studied after extensive cleaning procedures. In the sand samples treated with either hydrogen peroxide (H 2 O 2 ) or hydrofluoric acid (HF), there was a prominent TL peak at about 220 o C after γ-irradiation and 120 o C, 20 min post-irradiation annealing treatment. The dose vs TL response curves in hydrogen-peroxide-treated and HF-treated sand samples were found to be linear up to 30 and 100 Gy, respectively, beyond which they were supra-linear. The extent of post-irradiation fading in the sand sample, which was treated with H 2 O 2 and post-irradiation annealed at 120 o C for 20 min, was observed to be 8% after 21 days, while no detectable fading was observed for the sample which was HF treated and annealed at 120 o C for 20 min after γ-irradiation. Therefore, H 2 O 2 - as well as HF-treated sludge sand samples could be considered for use as in situ TL dosimeters for radiation disinfection of sewage sludge. (Author)

  14. Comparison of functional parameters of CsI:Tl crystals and thick films

    International Nuclear Information System (INIS)

    Fedorov, A.; Gektin, A.; Lebedynskiy, A.; Mateychenko, P.; Shkoropatenko, A.

    2013-01-01

    500 mkm thick CsI:Tl columnar films can be produced using thermal evaporation in vacuum by sublimation of the same bulk crystal. Comparison of afterglow and radiation stability of deposited CsI:Tl films with source crystal was the aim of current work. It is shown that the afterglow in the films is always below its level in initial single crystal. It was ascertained that the annealing atmospheres influence the processes leading to the activator depletion of the films during the thermal processing. -- Highlights: ► Thick CsI:Tl columnar films were obtained by thermal evaporation in vacuum. ► Radiation stability of such CsI:Tl films appears to be better than that of crystal. ► CsI:Tl film parameters can be modified by annealing in different atmospheres

  15. Automation of TL brick dating by ADAM-1

    International Nuclear Information System (INIS)

    Cechak, T.; Gerndt, J.; Hirsl, P.; Jirousek, P.; Kubelik, M.; Musilek, L.; Kanaval, J.

    2000-01-01

    Thermoluminescence has become an established dating method for ceramics and more recently for bricks. Based on the experiences of the work carried out since the late 1970's at the Rathgen-Forschungslabor in Berlin on the dating of bricks from historic architecture, and after evaluating all commercially available and some individually built automated and semi-automated TL-readers, a specially adapted machine for the fine grain dating of bricks was constructed in an interdisciplinary research project, undertaken by a team recruited from three faculties of the Czech Technical University in Prague. The result is the automated TL-reader ADAM-1 (Automated Dating Apparatus for Monuments) for the dating of historic architecture. Both the specific adaptation of the technique and the necessary optimal automation have influenced the design of this TL-reader. The principle advantage of brick as opposed to ceramic TL-dating emerges from the possibility of being able to obtain both a large number of samples and an above average quantity of datable material from each sample. This, together with the specific physical and chemical conditions in a brick wall, allowed a rethinking of the traditional error calculation and thus lower error margins as those obtained when dating ceramic shards. The TL-reader must therefore be able to measure and evaluate automatically numerous samples. The annular sample holder of ADAM-1 has 60 sample positions, which allow the irradiation and evaluation of samples taken from two locations. The thirty samples from one sampling point are divided into subgroups, which are processed in various ways. Three samples serve for a rough estimate of the TL sensitivity of the brick material. Nine samples are used for the measurement of 'natural TL' of the material. A further nine samples are used for testing the sensitivity of the material to beta radiation. The last nine samples serve for the testing of the sensitivity to alpha radiation. To determine the

  16. X-ray dosimetry of TlGaSe2 single crystals

    International Nuclear Information System (INIS)

    Kerimova, E.M.; Mustafaeva, S.N.; Mamedbeili, S.D.; Jabarov, J.N.; Iskenderova, P.M.; Kazimov, S.B.

    2002-01-01

    TlGaSe 2 compound belongs to group of layered semiconductors of A 3 B 3 C 2 6 -type. Photoelectric and optical properties of TlGaSe 2 single crystals were investigated in detail. Influence of gamma-, electron and neutron radiation on photoelectric properties of TlGaSe 2 single crystals is investigated too. The present work deals with experimental results relative to X-ray dosimetric characteristics of TlGaSe 2 crystals at 300 K. X-ray conductivity and X-ray dosimetric characteristic measurements are carried out in low load resistance regime. The source of X-ray radiation is the installation of X-ray diffraction analysis (URS-55a) with the BCV-2(Cu). Intensity of X-ray radiation (E) is regulated by measurement with current variation in tube at each given value of X-ray radiation dose E (R/min) are measured by crystal dosimeter DRGZ-02. X-ray conductivity coefficients K σ characterising X-ray sensitivity of investigated crystals are determined as the relative change of conductivity under X-ray radiation a per dose. There have been determined values of characteristic coefficients of TlGaSe 2 single crystal X-ray conductivity at different values of accelerating voltage (V a ) on the tube and corresponding doses of X-ray radiation. Analysis of obtained data showed that X-ray conductivity coefficients K σ in studied crystals are regularly decreased (from 0.276 to 0.033) as with the rise of dose (E=0.75-78.0 R/min) as with the increase of values of V a on X-ray tube (V a =254-50 keV). One of the possible reasons of observed regularities is that X-ray conductivity in investigated crystals, especially at comparatively low V a is due predominantly to radiation of thin layer of crystal. In this case with the rise of radiation intensity there have been started to prevail the mechanism of surface quadratic recombination which leads to observed decrease of X-ray conductivity. With the rise of accelerating potential 'effective hardness' is increased, as a result of which there

  17. Real-time in-situ monitoring of the topotactic transformation of TlCu3Se2 into TlCu2Se2

    International Nuclear Information System (INIS)

    Ångström, J.; Sahlberg, M.; Berger, R.

    2015-01-01

    Highlights: • Topotactic transition from TlCu 3 Se 2 to TlCu 2 Se 2 followed in situ. • Synchrotron radiation X-ray powder diffraction enabled short scans. • Relative abundance of phases refined from powder data. • Opens up for studying similar systems in the same manner. - Abstract: The solid state transformation of monoclinic TlCu 3 Se 2 into tetragonal TlCu 2 Se 2 by oxidative copper leaching in concentrated ammonia solution has been studied in situ by the use of synchrotron radiation. The diffraction patterns of parent and daughter phase are both sharp, indicating a strong topotactic relationship between them that effectuates a rapid change by “chimie douce” performed at +19 °C. The transformation rate is strongly connected to the access of oxygen from the surrounding air. The transformation was followed in a real-time mode, being almost complete after 2.5 h with 1 h incubation due to low oxygen content, as shown from refining the diffraction patterns by Rietveld profile technique

  18. Intrinsic thermoluminescence of NaCl:Tl in UV dosimetry

    International Nuclear Information System (INIS)

    Barghare, S.P.; Joshi, R.V.; Joshi, T.R.; Kathuria, S.P.

    1982-01-01

    NaCl:Tl(T) phosphor is found to have high intrinsic thermoluminescence (TL) sensitivity to 253.7 nm UV-radiation. The dosimetric glow peak II grows sublinearly with increase in UV dose in the range 10 3 to 10 6 JM -2 . The other requirements of an efficient dosimeter material such as high storage stability, matching of the spectral response of detector tube and TL-emission from phosphor, reproducibility, desirable size and shape, easy availability in powder, pellet and crystal forms at cheaper rates, and repeated re-usability of the same phosphor without much difficulty, etc., are additional factors which strengthen the claim of NaCl:Tl(T) phosphor as UV dosimetric material. It is proposed that present NaCl:Tl(T) material is suitable TL-phosphor for UV dosimetry in the range 10 3 to 10 6 JM -2 . (author)

  19. The neutron diffraction of molten TlCl, TlBr, and TlI

    International Nuclear Information System (INIS)

    Satow, T.; Uemura, O.; Hoshino, K.; Watanabe, T.

    1984-01-01

    Structure factors S(K) for liquid TlCl, TlBr, and TlI are determined by neutron diffraction measurements. Atomic radial distribution functions (RDF) derived from S(K) are presented. All RDF values are slightly smaller than those of their solid state counter parts. Results show that TlX has a tendency not to retain cesium-chloride type local order, but to take sodium-chloride type order when melting

  20. Photo-TL in CaSO4:Dy: high exposure dosimetry

    International Nuclear Information System (INIS)

    Caldas, L.V.E.; Mayhugh, M.R.

    1974-01-01

    CaSO 4 :Dy exposed to 10 3 to 10 8 R then annealed in the range 280 to 400 0 C displays little TL in the major dosimetry peak near 200 0 C. Subsequent illumination with 250 nm light reinduces the 200 0 C TL. This radiation-enabled photo-TL is roughly proportional to the square root of the enabling exposure at least to 10 8 R. (auth)

  1. Relative response of TL and component-resolved OSL to alpha and beta radiations in annealed sedimentary quartz

    International Nuclear Information System (INIS)

    Polymeris, George S.; Afouxenidis, Dimitrios; Raptis, Spyridoula; Liritzis, Ioannis; Tsirliganis, Nestor C.; Kitis, George

    2011-01-01

    Knowledge of the relative luminescence response to alpha and beta radiation is very important in TL and OSL dating. In the present study the relative alpha to beta response is studied in a sedimentary quartz sample, previously fired at 900 deg. C for 1 h, in the dose region between 1 and 128 Gy, for both thermoluminescence (TL) and linearly modulated optically stimulated luminescence (LM - OSL). The LM - OSL measurements were performed at room temperature and at 125 deg. C. All OSL signals were deconvolved into their individual components. Comparison of OSL curves after alpha and beta irradiation strongly supports that quartz OSL components follow first order kinetics in both cases. In the case of TL, the relative alpha to beta response is found to be very different for each TL glow-peak, but it does not depend strongly on irradiation dose. In the case of LM - OSL measurements, it is found that the relative behaviour of the alpha to beta response is different for three distinct regions, namely the fast OSL component, the region of medium OSL component originating from the TL glow-peak at 110 deg. C when stimulation takes place at room temperature and finally the region of slow OSL component. Following stimulation at ambient temperature, the relative alpha to beta response of all components was not observed to depend significantly on dose, with the value of ratio being 0.03 and a tendency to decrease with increasing dose. However, in the case of measurements performed at 125 deg. C, the relative response of the fast components is much enhanced, and for the remaining components it increases with increasing dose. Special care must be taken to examine the relative alpha to beta response of the fast component at 125 deg. C which contrasts the relative response of the TL peak at ca. 325 deg. C. The implications for the dating of annealed quartz are also briefly discussed. - Highlights: → Relative alpha to beta response for TL and LM-OSL is studied in annealed

  2. Determination of kinetic parameters in Tl dosemeters of LiF: Mg, Cu, P + PTFE developed in the ININ; Determinacion de parametros cineticos en dosimetros Tl de LiF: Mg, Cu, P + PTFE desarrollados en el ININ

    Energy Technology Data Exchange (ETDEWEB)

    Basurto G, B.S

    2002-07-01

    The objective of this work, is the one of determining the kinetic parameters of the dosemeter of LiF: Mg, Cu, P + Ptfe; starting from the curves Tl obtained at being irradiated with alpha radiation ({alpha}), beta ({beta}) and gamma ({gamma}). As like to compare its sensitivity with each radiation type, considering the sensitivity of the TLD-100 as the unit. In the Chapter 1, the fundamental structure of the matter is described, making emphasis in the different radiation types, and their interaction with this. In the Chapter 2, the units are described but used in the dosimetry of the radiation. In the Chapter 3, the basic concepts of the phenomenon of Tl are described and those are explained characteristic of the deconvolution method to determine the kinetics of the one phenomenon. In the Chapter 4, the methodology is detailed that was used in the elaboration of this thesis work, describing the material Tl that were considered like reference, as well as the sources of ionizing radiation, with those that the dosemeters were irradiated and the equipment in the one that the curves Tl was obtained. Reference is made to the software used to carry out the deconvolution of the curves Tl that were obtained in the one experimental development. In the Chapter 5, the obtained results of this study are presented, showing the tables of homogenization of dosemeters and the reading of the same one; they are observed the curves Tl obtained to different radiation doses (alpha, beta and gamma), the intensity Tl in function of the dose. Also they are tabulated, the obtained results in the kinetic parameters of the three different study materials (TLD-100H, USA; TLD-100, USA and LiF: Mg, Cu, P + Ptfe developed in the l.N.l.N). They are analyzed shortly for each material Tl their sensitivity to the ionizing radiation as well as their kinetic parameters. The obtained results showed that the Tl dosemeters of LiF: Mg,Cu,P + Ptfe, they presented a bigger sensitivity that the TLD-100 when

  3. ESR and TL age determination of caliche nodules

    Energy Technology Data Exchange (ETDEWEB)

    Oezer, A.M. (Middle East Technical Univ., Ankara (Turkey)); Wieser, A.; Goeksu, H.Y.; Mueller, P.; Regulla, D.F. (Gesellschaft fuer Strahlen- und Umweltforschung mbH Muenchen, Neuherberg (Germany, F.R.). Inst. fuer Strahlenschutz); Erol, O. (Istanbul Univ. (Turkey). School of Geography and Marine Sciences)

    1989-01-01

    Feasibility of dating caliche nodules by ESR and TL is investigated. For both methods the properties of the dating signal are described. Chemical composition as well as TL glow curves of caliches originating from different localities exhibit some differences. Due to the complexity of the TL glow curves, some samples required a special post-annealing procedure in order to resolve the main TL peak for age determination. Typical ESR calcite signals do not exist in caliche, therefore usefulness of the g=2.0040 ESR signal is studied. The results of TL and ESR ages are found to be compatible except for two samples. Possible causes of the discrepancy in these samples are discussed. It is shown that, with proper treatment of the radiation-induced signals, it was possible to date caliche formations older than 350 ka, which is not achievable with other methods like uranium series disequilibrium and/or radiocarbon dating. (author).

  4. ESR and TL age determination of caliche nodules

    International Nuclear Information System (INIS)

    Oezer, A.M.; Wieser, A.; Goeksu, H.Y.; Mueller, P.; Regulla, D.F.; Erol, O.

    1989-01-01

    Feasibility of dating caliche nodules by ESR and TL is investigated. For both methods the properties of the dating signal are described. Chemical composition as well as TL glow curves of caliches originating from different localities exhibit some differences. Due to the complexity of the TL glow curves, some samples required a special post-annealing procedure in order to resolve the main TL peak for age determination. Typical ESR calcite signals do not exist in caliche, therefore usefulness of the g=2.0040 ESR signal is studied. The results of TL and ESR ages are found to be compatible except for two samples. Possible causes of the discrepancy in these samples are discussed. It is shown that, with proper treatment of the radiation-induced signals, it was possible to date caliche formations older than 350 ka, which is not achievable with other methods like uranium series disequilibrium and/or radiocarbon dating. (author)

  5. Doped Tl-1212 and Tl-1223 superconductors

    International Nuclear Information System (INIS)

    Eder, M.H.

    2001-09-01

    This work describes the preparation and characterization of thallium-lead-strontium-barium-calcium-(uranium)-copperoxide (Tl-1212, Tl-1223) high-temperature superconductors. The precursors were prepared via nitrate method. After calcination the oxidic powders were mixed with stoichiometric amounts of an Tl 2 O 3 , PbO, Er 2 O 3 and Gd 2 O 3 by milling and afterwards uniaxial compressed. Sintering was carried out in silver foils. X-ray diffractometry and high-resolution microscopy in combination with scanning electron microscopy (including EDAX) were used to study the influence of varying thallium/lead-, strontium/barium-, calcium/rare earth element ratios and the effect of uranium on the phase composition and microstructure of bulk superconductors. Furthermore the influence of the composition on the electrical and magnetical properties was studied. On phase pure Tl-1212 and Tl-1223 superconductors NMR-measurements were done. Small amounts of gadolinium and erbium instead of calcium and excess-uranium have a positive impact on the electrical and magnetical properties of the Tl-1223 superconductors. Higher amounts of these doping elements favor the Tl-1212 phase. Tl-1212 superconductors with varying thallium/lead- strontium/barium- and calcium/gadolinium ratios were prepared phasepure in wide range of doping. Transition temperatures up to 96 K were achieved. It was shown that lead has an oxidation number of +4 and thallium of +3. (author)

  6. Preliminary results on TL and OSL aluminium oxide dosimeters developed at IPEN

    Energy Technology Data Exchange (ETDEWEB)

    Fukumori, David T.; Yoshito, Walter K.; Ussui, Valter; Lazar, Dolores R.R.; Campos, Leticia L., E-mail: fukumori@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    The aluminum oxide composes the modern TL and OSL radiation dosimeters. TL and OSL phenomena are related to chemical elements in the crystalline structure of {alpha}-Al{sub 2}O{sub 3}. The aim of this work was to develop materials based on aluminum oxide for use in TL and OSL dosimetry. The studies included the dosimetric properties of alumina samples obtained by electro fusion, adsorption and coprecipitation. Electro fused alumina commercially available as abrasive particles was used to produce the pellets by glass sintering. Adsorption and coprecipitation were the methods used to insert metal ions to alumina. The best results were achieved with electro fused alumina and Tm{sup 3+} doped Al{sub 2}O{sub 3} pellets. The electro fused alumina-glass pellets show TL and OSL signals and the TL curve has two peaks. Its minimum detectable radiation dose is 7.2 mGy and the linearity of TL response as function of dose is up to about 800 mGy. The {alpha}-Al{sub 2}O{sub 3}:Tm pellets produced by sintering at 1550 deg C presented a meaningful TL glow curve so that it is worth studying their properties and viability of use in dosimetry. (author)

  7. Sand as in situ TL dosimeter in radiation hygienisation of sewage sludge

    International Nuclear Information System (INIS)

    Benny, P.G.; Bhatt, B.C.

    1999-01-01

    Recently, we have investigated the thermoluminescence (TL) properties of the sand, collected from the sewage sludge, after various extensive cleansing procedures. In the present studies, the sand separated from the sludge was used to estimate irradiation dose to sludge at Sludge Hygienisation Research Irradiator (SHRI), Vadodara, India. A dose vs TL response calibration curve was established for the 220 deg. C TL peak for the hydrogen peroxide (H 2 O 2 )-treated and HF-treated sludge sand samples collected from the unirradiated batch. This was used to estimate the dose absorbed in the corresponding batch of the irradiated sludge. Similar curve was plotted for the 370 deg. C TL peak for the HF-treated sand samples for its application as an in-situ dosimeter. Using this method, the absorbed dose rate delivered to the sludge during irradiation at SHRI was estimated to be 0.49 ± 0.02 kGy per hour. Also, the saturation levels of the TL response curves for these peaks are reported here. (author)

  8. Spectrophotometric determination of Tl carrier in 201Tl-TlCl injection

    International Nuclear Information System (INIS)

    Gong Quansheng; Jing Lie

    1997-01-01

    A simple and sensitive method for the spectrophotometric determination of carrier content (Thallium) in 201 Tl-TlCl injection is described. Thallium (I) is oxidised to Thallium (III) by aqueous bromine, then excess bromine is removed by adding sulfosalicylic acid. In buffer solution (NH 4 Cl-NH 4 OH) at pH 11.7 with the presence of emulsifier OP, thallium (III) and cadion form a complex having an absorption maximum at 469 nm with a molar absorptivity of 1.37 x 10 4 m 2 /mol. Beer's law is obeyed in the concentration range of 0-7 μg/5 mL. The effect of impurity elements in 201 Tl-TlCl injection is examined. It is an ideal method for the analysis of radioactive solution

  9. Real-time in-situ monitoring of the topotactic transformation of TlCu{sub 3}Se{sub 2} into TlCu{sub 2}Se{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Ångström, J.; Sahlberg, M.; Berger, R.

    2015-07-15

    Highlights: • Topotactic transition from TlCu{sub 3}Se{sub 2} to TlCu{sub 2}Se{sub 2} followed in situ. • Synchrotron radiation X-ray powder diffraction enabled short scans. • Relative abundance of phases refined from powder data. • Opens up for studying similar systems in the same manner. - Abstract: The solid state transformation of monoclinic TlCu{sub 3}Se{sub 2} into tetragonal TlCu{sub 2}Se{sub 2} by oxidative copper leaching in concentrated ammonia solution has been studied in situ by the use of synchrotron radiation. The diffraction patterns of parent and daughter phase are both sharp, indicating a strong topotactic relationship between them that effectuates a rapid change by “chimie douce” performed at +19 °C. The transformation rate is strongly connected to the access of oxygen from the surrounding air. The transformation was followed in a real-time mode, being almost complete after 2.5 h with 1 h incubation due to low oxygen content, as shown from refining the diffraction patterns by Rietveld profile technique.

  10. Determination of kinetic parameters in Tl dosemeters of LiF: Mg, Cu, P + PTFE developed in the ININ

    International Nuclear Information System (INIS)

    Basurto G, B.S.

    2002-01-01

    The objective of this work, is the one of determining the kinetic parameters of the dosemeter of LiF: Mg, Cu, P + Ptfe; starting from the curves Tl obtained at being irradiated with alpha radiation (α), beta (β) and gamma (γ). As like to compare its sensitivity with each radiation type, considering the sensitivity of the TLD-100 as the unit. In the Chapter 1, the fundamental structure of the matter is described, making emphasis in the different radiation types, and their interaction with this. In the Chapter 2, the units are described but used in the dosimetry of the radiation. In the Chapter 3, the basic concepts of the phenomenon of Tl are described and those are explained characteristic of the deconvolution method to determine the kinetics of the one phenomenon. In the Chapter 4, the methodology is detailed that was used in the elaboration of this thesis work, describing the material Tl that were considered like reference, as well as the sources of ionizing radiation, with those that the dosemeters were irradiated and the equipment in the one that the curves Tl was obtained. Reference is made to the software used to carry out the deconvolution of the curves Tl that were obtained in the one experimental development. In the Chapter 5, the obtained results of this study are presented, showing the tables of homogenization of dosemeters and the reading of the same one; they are observed the curves Tl obtained to different radiation doses (alpha, beta and gamma), the intensity Tl in function of the dose. Also they are tabulated, the obtained results in the kinetic parameters of the three different study materials (TLD-100H, USA; TLD-100, USA and LiF: Mg, Cu, P + Ptfe developed in the l.N.l.N). They are analyzed shortly for each material Tl their sensitivity to the ionizing radiation as well as their kinetic parameters. The obtained results showed that the Tl dosemeters of LiF: Mg,Cu,P + Ptfe, they presented a bigger sensitivity that the TLD-100 when being

  11. Converting Hg-1212 to Tl-2212 via Tl-Hg cation exchange in combination with Tl cation intercalation

    International Nuclear Information System (INIS)

    Zhao Hua; Wu, Judy Z

    2007-01-01

    In a cation exchange process developed recently for epitaxy of HgBa 2 CaCu 2 O 6 (Hg-1212) thin films, TlBa 2 CaCu 2 O 7 (Tl-1212) or Tl 2 Ba 2 CaCu 2 O 9 (Tl-2212) precursor films were employed as the precursor matrices and Hg-1212 was obtained by replacing Tl cations on the precursor lattice with Hg cations. The reversibility of the cation exchange dictates directly the underlying mechanism. Following our recent success in demonstrating a complete reversibility within '1212' structure, we show the conversion from Hg-1212 to Tl-2212 can be achieved via two steps: conversion from Hg-1212 to Tl-1212 followed by Tl intercalation to form double Tl-O plans in each unit cell. The demonstrated reversibility of the cation exchange process has confirmed the process is a thermal perturbation of weakly bonded cations on the lattice and the direction of the process is determined by the population ratio between the replacing cations and that to be replaced

  12. Response function study of a scintillator detector of NaI(Tl); Estudo da funcao resposta de um detector cintilador de NaI(Tl)

    Energy Technology Data Exchange (ETDEWEB)

    Villa, Marcelo Barros; Costa, Alessandro Martins da, E-mail: amcosta@usp.br [Universidade de Sao Paulo (FFCLRP/USP), Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras. Dept. de Fisica

    2014-07-01

    In measurements of gamma rays with Nai (Tl) scintillator, the detectors output data are pulse height spectra, that corresponding to distorted information about the radiation source due to various errors associated with the crystal scintillation process and electronics associated, instead of power spectra photons. Pulse height spectra are related to the real power spectra by means of scintillator detector response function NaI (Tl). In this work, the response function for a cylindrical crystal of Nal (Tl) of 7,62 x 7,62 cm (diameter x length) was studied, by Monte Carlo method, using the EGSnrc tool to model the transport of radiation, combined with experimental measurements. An inverse response matrix, even with the energy of the square root, which transforms the pulse height spectrum of photon energy spectrum was obtained. The results of this transformation of pulse height spectrum for photon energy spectrum is presented, showing that the methodology employed in this study is suitable.

  13. TL and OSL studies on undoped diamond films grown by hot filament chemical vapor deposition

    Energy Technology Data Exchange (ETDEWEB)

    Soni, Anuj, E-mail: anujsoni.phy@gmail.com [Radiological Physics and Advisory Division, Bhabha Atomic Research Center, Mumbai 400 085 (India); Choudhary, R.K. [Materials Processing Division, Bhabha Atomic Research Center, Mumbai 400 085 (India); Polymeris, G.S. [Ankara University, Institute of Nuclear Sciences (Turkey); Mishra, D.R. [Radiological Physics and Advisory Division, Bhabha Atomic Research Center, Mumbai 400 085 (India); Mishra, P. [Materials Processing Division, Bhabha Atomic Research Center, Mumbai 400 085 (India); Kulkarni, M.S. [Radiation Safety Systems Division, Bhabha Atomic Research Center, Mumbai 400 085 (India)

    2016-09-15

    In this work, approximately 0.5 µm thick diamond films were grown on a silicon substrate by hot filament chemical vapour deposition (HFCVD) method in a gas mixture of hydrogen and methane. The batch to batch reproducibility of the sample using this technique was found to be very good. The obtained film was characterized by micro laser Raman spectroscopy (MLRS), grazing incidence X-ray diffractometry (GIXRD), scanning electron microscopy (SEM) and atomic force miscroscopy (AFM) techniques. MLRS and GIXRD results confirmed the formation of diamond whereas SEM and AFM analyses indicated uniform morphology of the film with an average grain size of 200 nm. The deposited film was studied for ionizing radiation dosimetry applications using the thermoluminescence (TL) and optically stimulated luminescence (OSL) techniques after irradiating the film by a calibrated 5 mCi, {sup 90}Sr/{sup 90}Y beta source. In the TL measurement, for a heating rate of 4 K/s, broad glow curve was obtained which was deconvoluted into seven TL peaks. The integrated TL counts were found to vary linearly with increasing the radiation dose up to 10 kGy. The characteristic TL output seen in the temperature range 200–300 °C, may be considered good for thermal stability of the film and it could also avoid TL fading during storage and non-interference of any black body radiation during the measurement. However, in comparison to TL output, the OSL response for 470 nm LED stimulation was found to be lesser. The CW–OSL decay curve has shown two components contributing to the OSL signal, having photoionization cross-section 1.5×10{sup −18} and 5.2×10{sup −19} cm{sup 2} respectively. The studies have revealed the possibility of using diamond film for high dose radiation dosimetry with TL/OSL method.

  14. Characterization of TL dosimeters for determination of the gamma component in a mixed n+γ radiation field

    International Nuclear Information System (INIS)

    Ranogajec-Komor, M.; Miljanic, S.; Ferek, S.; Dvornik, I.; Osvay, M.

    1996-01-01

    In the International Intercomparison of the Criticality Accident Dosimetry Systems organized by the Commission of European Communities at SILENE Reactor in Valduc, France, 1993, the Ruder Boskovic Institute (RBI) measured the total neutron and gamma tissue absorbed dose (D n+γ ) at the body surface irrespective of neutron and gamma energy spectra variations using the chemical dosimeters DL-M4. For deriving the neutron dose i.e recoil dose, D n , from the differences D n = D n+γ - D t , the total gamma dose (D tγ ) has to be measured with highest accuracy. The determination of the gamma dose in a mixed field is complicated because TL dosimeters are sensitive both to neutrons and gammas. Besides, the radiation doses and energy spectra vary because of scattering and absorption in the body or phantom. Therefore dosimeters with different sensitivities, energy dependences and encapsulations have to be used. In this paper only the study of some characteristics of various TL detectors, such as sensitivity, linearity, supralinearity and fading, for measurement of the gamma component are described. These investigations were carried out in RBI before and after the Valduc intercomparison experiments. The encapsulations, TL response corrections for thermal and fast neutron effects as well as the discussion of Valduc results will be published later

  15. Tl and OSL dosimetry of diamond films CVD pure and unpurified with boron-carbon; Dosimetria Tl y OSL de peliculas de diamante CVD puras e impurificadas con boro-carbono

    Energy Technology Data Exchange (ETDEWEB)

    Melendrez, R.; Pedroza M, M.; Chernov, V.; Ochoa N, J.D.; Bernal, R.; Barboza F, M. [CIF, UNISON, A.P. 5-088, 83190 Hermosillo, Sonora (Mexico); Castaneda, B. [Departamento de Fisica, Universidad de Sonora, Apdo. Postal 1626, Hermosillo, Sonora (Mexico); Goncalves, J.A.N.; Sandonato, G.M. [Laboratorio Associado de Plasma, Instituto Nacional de Pesquisas Espaciais C.P. 515- 12201 -970, Sao Jose dos Campos, SP (Brazil); Cruz Z, E. [Instituto de Ciencias Nucleares, UNAM, Apdo. Postal 70-543, 04510 Mexico D.F. (Mexico); Preciado F, S.; Cruz V, C.; Brown, F. [Departamento de Investigacion en Polimeros y Materiales de la Universidad de Sonora, Apdo. Postal 130, 83000 Hermosillo, Sonora (Mexico); Schreck, M. [Universitaet Augsburg, Institut fuer Physik D-86135 Augsburg (Germany)

    2004-07-01

    The diamond is a material that possesses extreme physical properties, such as its hardness to the radiation, its low chemical reactivity besides its equivalence to the human tissue, which qualify him as an ideal material for radiation dosimetry. In this work, it was studied the thermal and optically stimulated response (Tl and OSL) of polycrystalline diamond films grown by the technique of CVD pure and contaminated with Boron-carbon (B/C) with the intention of characterizing their efficiency like a dosemeter for radiation in a range of 0 - 3000 Gy. For the case of the films without impurities, the Tl curve presents four main peaks, two of them in an interval of temperatures of 150-200 C and other two additional around of 250-400 C. The dependence of the response of integrated Tl and that of OSL always maintained a lineal relationship with the exhibition dose up to 100 Gy. The behavior of the films contaminated with B/C (2000 - 20000 ppm) was established through experiments that involved the signal of OSL and their relationship with the Tl response. It was found that this processes are correlated, since the electrons caught in the traps of low temperature (50 - 250 C) of the Tl they are the electrons that recombining with more probability to provide the signal of OSL. According to these results it is possible to propose the diamond films as a good candidate for dosimetry to, using the traditional technique of Tl so much as well as the but recent of OSL. (Author)

  16. Trithallium tetraselenophosphate Tl3PSe4, and trithallium tetrathioarsenate, Tl3AsS4, by neutron time-of-flight diffraction

    International Nuclear Information System (INIS)

    Alkire, R.W.; Vergamini, P.J.; Larson, A.C.; Morosin, B.

    1984-01-01

    Room-temperature (293 K) single-crystal structure determinations of the isostructural materials Tl 3 PSe 4 and Tl 3 AsS 4 were performed at the Los Alamos National Laboratory Pulsed Neutron Facility. For Tl 3 PSe 4 : Msub(r) = 959.92, Pcmn, a = 9.276 (1), b = 11.036 (2), c = 9.058 (1) A, V = 927.27 A 3 , Z = 4, Dsub(m) = 6.87 (2), Dsub(x) = 6.876 Mg m -3 , lambdasub(neutron) = 0.5 → 5.2 A, F(000) = 252.5 fm. For Tl 3 AsS 4 : Msub(r) = 816.29, Pcmn, a = 9.084 (3), b = 10.877 (3), c = 8.877 (3) A, V = 877.11 A 3 , Z = 4, Dsub(m) = 6.18 (2), Dsub(x) = 6.181 Mg m -3 , lambdasub(neutron) = 0.5 → 5.2 A, F(000) = 177.2 fm. For Tl 3 PSe 4 (Tl 3 AsS 4 ), 1929 (1013) reflections were measured with I > 3sigma(I) and refined by full-matrix least squares to R(F) = 0.061 (0.063). Results on atomic refinement from this study represent an order of magnitude increase in precision over previous single-crystal X-ray structural work using Mo Kα radiation. The PSe 4 3- (AsS 4 3- ) groups have essentially tetrahedral configurations and one Tl + ion shows large anisotropic thermal motion which is structure related. (Auth.)

  17. Measurements of environmental gamma-ray spectra using a multi-element TL dosemeter

    International Nuclear Information System (INIS)

    Furuta, Sadaaki; Boetter-Jensen, L.; Nielsen, S.P.

    1986-12-01

    A method to estimate the energy distribution and dose of environmental gamma radiation was developed using a multielement TL dosemeter. Experimentally obtained energy responses from a multi-element TL dosemeter with different kinds of filters were used to calculate the energy distribution and related dose by the SAND-II computer code. The code was originally developed to estimate the neutron flux using a multiple foil activation method. Measurements were made at several locations with the multi-element TL dosemeter and comparisons were made with results from a NaI(Tl) scintillation detector and a high-pressure ionization chamber. (author)

  18. Natural quartz TL property and similarity in Piper nigrum L

    International Nuclear Information System (INIS)

    Guzman A, S.; Cruz Z, E.; Furetta, C.; Brown, F.; Barboza F, M.

    2009-10-01

    Quartz is a mineral abundant in nature and can provide information thermoluminescent (TL), and also is located in the mineral fraction of some herbs and spices consumed. It is present the analysis of the TL properties of a sample of natural quartz rock and compared with those obtained from the fraction of Piper nigrum L. poly mineral when they were exposed to 60 Co gamma radiation. The poly minerals of Piper nigrum L. were analyzed by X-ray diffraction, where the quartz was found as a major component. They separated in different particle sizes (10, 53, 74 and 149 μm). The samples were irradiated at relatively low doses (1-500 Gy) and high (0.1-40 kGy) in order to determine the linearity of the TL emission as a function of the dose and the analysis of glow curves. Also there was the fading of the TL signal, the effect of ultra violet light. The reproducibility of the TL signal in the samples indicates that a smaller particle size gives better TL signal. (author)

  19. OSL and TL retrospective dosimetry with a fluorapatite glass-ceramic used for dental restorations

    International Nuclear Information System (INIS)

    Ekendahl, Daniela; Judas, Libor; Sukupova, Lucie

    2013-01-01

    Optically Stimulated Luminescence (OSL) and Thermoluminescence (TL) properties of a fluorapatite glass-ceramic have been investigated, with a view to developing a dose assessment technique for medical triage following unplanned exposures of individuals to ionizing radiation. The ceramic is an innovative material used in dental prostheses and restorations. It is strongly sensitive to radiation and the intensity of both the OSL and TL signals are proportional to the absorbed radiation dose. We focused on the optimization of the measuring procedure and investigated characteristics such as reproducibility, fading, minimum detectable dose (MDD), dose response and photon energy response of TL and OSL signals. The dental ceramic exhibited very good reproducibility (<5% at 2σ level) when measured and a linear dose response for a wide range of doses (50 mGy–20 Gy). The MDD values for the samples investigated were ∼5 mGy. The material is not tissue equivalent and the OSL and TL signals are strongly dependent on incident photon energy. Both the luminescence signals exhibited significant fading during the first few hours after irradiation. Its rate was dependent on the parameters of measurement. The results indicate that the material can be used for the purposes of accident dosimetry, however, the fading and photon energy response have to be properly corrected for a reliable dose assessment. - Highlights: ► A dental ceramic was considered as a retrospective and accident dosimeter. ► Dosimetry application was investigated using OSL and TL. ► TL and OSL signals are proportional to absorbed radiation dose. ► Accuracy is dependent on correction of fading and photon energy response

  20. Measurement of effective dose in clinic radiation diagnosis with TL dosimeters developed in Mexico; Medicion de dosis efectiva en radiodiagnostico clinico con dosimetros TL desarrollados en Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez Martinez, Pedro R. [Instituto Nacional de Investigaciones Nucleares, Mexico, D.F. (Mexico); Azorin Nieto, Juan [Universidad Autonoma Metropolitana-Iztapalapa, Mexico D.F. (Mexico); Gonzalez Urquidi, Blanca [Universidad Veracruzana, Xalapa (Mexico); Maldonado Sanchez, Guadalupe [Instituto Mexicano del Seguro Social (IMSS), Toluca (Mexico). Hospital de Gineco Obstetricia

    2001-07-01

    At the moment the radiation diagnosis is one of the main causes of exposition to the ionizing radiations, and in many of the cases the limits to the limits of dose established by the Commission the International of Radiological safety are not applied. In this work the results obtained in the measurement of the effective dose with dosemeters Tl of LiF:Mg,Cu, P+PTFE developed in the National Institute of Nuclear Investigations (ININ), in patients to studies of clinical radiation diagnosis of urography and hysterosalpingography. The effective dose was considered in gonads, breasts and thyroid. Whereas in the radiologist physician the dose was measured in crystalline, thyroid and hands, in this work ware made whole body measurements in addition. The results showed that the dose received by patients is equivalent with the results reported in Literature; in the case of the radiologist physician, the dose considered in the made studies is below the limits recommended for POE.

  1. Superconducting transition in TlBiTe/sub 2/ and TlTe compounds

    Energy Technology Data Exchange (ETDEWEB)

    Kantser, V G; Popovich, N S; Sidorenko, A S

    1985-10-01

    On the basis of zone structure calculation for TlBiTe/sub 2/ and TlTe it is found that TlBiTe/sub 2/ is a narrow-gap semiconductor and TlTe is a p-metal. At Tsub(c)=0.19 K TlTe is found to experience the superconducting transition. In TlBiTe/sub 2/ superconductivity is not observed to occur up to 0.05 K, since there is a possibility of occupying the high density of states zones because they are remote from actual ones. The earlier discovered superconducting transition in TlBiTe/sub 2/ is inherent in the alien phase of TlTe.

  2. The use of thallium diethyldithiocarbamate for mapping CNS potassium metabolism and neuronal activity: Tl+ -redistribution, Tl+ -kinetics and Tl+ -equilibrium distribution.

    Science.gov (United States)

    Wanger, Tim; Scheich, Henning; Ohl, Frank W; Goldschmidt, Jürgen

    2012-07-01

    The potassium (K(+)) analogue thallium (Tl(+)) can be used as a tracer for mapping neuronal activity. However, because of the poor blood-brain barrier (BBB) K(+) -permeability, only minute amounts of Tl(+) enter the brain after systemic injection of Tl(+) -salts like thallium acetate (TlAc). We have recently shown that it is possible to overcome this limitation by injecting animals with the lipophilic chelate complex thallium diethyldithiocarbamate (TlDDC), that crosses the BBB and releases Tl(+) prior to neuronal or glial uptake. TlDDC can thus be used for mapping CNS K(+) metabolism and neuronal activity. Here, we analyze Tl(+) -kinetics in the rodent brain both experimentally and using simple mathematical models. We systemically injected animals either with TlAc or with TlDDC. Using an autometallographic method we mapped the brain Tl(+) -distribution at various time points after injection. We show that the patterns and kinetics of Tl(+) -redistribution in the brain are essentially the same irrespective of whether animals have been injected with TlAc or TlDDC. Data from modeling and experiments indicate that transmembrane Tl(+) -fluxes in cells within the CNS in vivo equilibrate at similar rates as K(+) -fluxes in vitro. This equilibration is much faster than and largely independent of the equilibration of Tl(+) -fluxes across the BBB. The study provides further proof-of-concept for the use of TlDDC for mapping neuronal activity and CNS K(+) -metabolism. A theoretical guideline is given for the use of K(+) -analogues for imaging neuronal activity with general implications for the use of metal ions in neuroimaging. © 2012 The Authors. Journal of Neurochemistry © 2012 International Society for Neurochemistry.

  3. Determination of the response of a NaI(Tl) detector; Determinacion de la respuesta de un detector de NaI(Tl)

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H.R.; Manzanares A, E.; Hernandez D, V.M.; Chacon R, A. [Universidad Autonoma de Zacatecas, A.P. 336, 98000 Zacatecas (Mexico)]. e-mail: fermineutron@yahoo.com

    2006-07-01

    By means of Monte Carlo calculations it was determined the response of a scintillator of NaI (Tl) of 7.62 {phi} x 7.62 cm to monoenergetic gamma rays of 0.2 to 3.5 MeV. The response allows to determine the spectra of height of pulses of the monoenergetic photons. This type of calculations was also carried out for photons emitted by sources of Cs-137, Co-60, Na-22, Na-24 and {sup 239} PuBe, with the purpose of reproducing the gamma spectra obtained with this type of detecting. In the calculations the detector was modelled as a NaI cylinder with Al cover and the base of lucite; due to the absence of reliable information on the quantity of thallium in the calculations this information was omitted: for photons whose energy is greater to 1.022 MeV the presence of the gamma peak of the simple escape and twice is observed. The source was modelled as punctual and was located to 5 cm along the axial axis of the detector. To verify the calculations its were carried out measurements with a spectrometer with a scintillator of 7.62 {phi} x 7.62 cm. In the measured spectra the sum peak is observed, while in those calculated it doesn't appear; because the simultaneous detection of photons of different energy doesn't happen each photon since, in single form, it is followed until its complete absorption in the scintillator or when it escapes from the volume of the detector. To reproduce the sum peak and to obtain height spectra of pulses similar to those measured, the sum photons were introduced in the calculations. With the purpose of that Monte Carlo calculation it reproduces the scattering around the photopeak it was used a gaussian function in each photopeak whose characteristics were obtained starting from the experimental data. The calculation of the response of a scintillator allows to establish the capacity of the measurement of the gamma radiation as well as to distinguish the real events of those that appear by the limitations of the detection process. (Author)

  4. A study of the impact of radiation exposure on the uniformity of large CsI(Tl) crystals for the BaBar detector

    International Nuclear Information System (INIS)

    Hryn'ova, Tetiana; Kim, Peter; Kocian, Martin; Perl, Martin; Rogers, Howard; Schindler, Rafe H.; Wisniewski, William J.

    2004-01-01

    We describe an apparatus that allows simultaneous exposure of large CsI(Tl) crystals to ionizing radiation and precise measurement of the longitudinal changes in light yield of the crystals. We present herein the results from this device for exposures up to 10krad

  5. Investigation of the gamma radiation from the inelastic scattering of 2.75 MeV on 203Tl and 205Tl

    International Nuclear Information System (INIS)

    Hegewisch, S.

    1976-01-01

    The experimental presupositions for the measurements of (n,n'γ) reactions with time of flight discrimination have been established. By an investigation of the isotopes 203 Tl and 205 Tl with this method 120 gamma-transitions could be determined. The exact evaluation of their energies and intensities led to a completion of the level diagrams. The enrgies could be determined with a precision nearly one order of magnitude higher than the values existing hither to. (orig./WL) [de

  6. Study on effects of gamma-ray irradiation on TlBr semiconductor detectors

    International Nuclear Information System (INIS)

    Matsumura, Motohiro; Watanabe, Kenichi; Yamazaki, Atsushi; Uritani, Akira; Kimura, Norihisa; Nagano, Nobumichi; Hitomi, Keitaro

    2016-01-01

    Radiation hardness of thallium bromide (TlBr) semiconductor detectors to 60 Co gamma-ray irradiation was evaluated. The energy spectra and μτ products of electrons were measured to evaluate the irradiation effects. No significant degradation of spectroscopic performance of the TlBr detector for 137 Cs gamma-rays was observed up to 45 kGy irradiation. Although the μτ products of electrons in the TlBr detector slightly decreased, position of the photo-peak was stable without significant degradation after the gamma-ray irradiation. We confirmed that the TlBr semiconductor detector has a high tolerance for gamma-ray irradiation at least up to 45 kGy. (author)

  7. The effects of chemical and radioactive properties of Tl-201 on human erythrocyte glucose 6-phosphate dehydrogenase activity

    International Nuclear Information System (INIS)

    Sahin, Ali; Senturk, Murat; Ciftci, Mehmet; Varoglu, Erhan; Kufrevioglu, Omer Irfan

    2010-01-01

    Aim: The inhibitory effects of thallium-201 ( 201 Tl) solution on human erythrocyte glucose 6-phosphate dehydrogenase (G6PD) activity were investigated. Methods: For this purpose, erythrocyte G6PD was initially purified 835-fold at a yield of 41.7% using 2',5'-Adenosine diphosphate sepharose 4B affinity gel chromatography. The purification was monitored by sodium dodecyl sulfate-polyacrylamide gel electrophoresis, which showed a single band for the final enzyme preparation. The in vitro and in vivo effects of the 201 Tl solution including Tl + , Fe +3 and Cu +2 metals and the in vitro effects of the radiation effect of the 201 Tl solution and non-radioactive Tl + , Fe +3 and Cu +2 metals on human erythrocyte G6PD enzyme were studied. Enzyme activity was determined with the Beutler method at 340 nm using a spectrophotometer. All purification procedures were carried out at +4 deg. C. Results: 201 Tl solution and radiation exposure had inhibitory effects on the enzyme activity. IC 50 value of 201 Tl solution was 36.86 μl ([Tl + ]: 0.0036 μM, [Cu +2 ]: 0.0116 μM, [Fe +3 ]: 0.0132 μM), of human erythrocytes G6PD. Seven human patients were also used for in vivo studies of 201 Tl solution. Furthermore, non-radioactive Tl + , Fe +3 and Cu +2 were found not to have influenced the enzyme in vitro. Conclusion: Human erythrocyte G6PD activity was inhibited by exposure for up to 10 minutes to 0.057 mCi/kg 201 Tl solution. It was detected in in vitro and in vivo studies that the human erythrocyte G6PD enzyme is inhibited due to the radiation effect of 201 Tl solution.

  8. Tl and OSL dosimetry of diamond films CVD pure and unpurified with boron-carbon

    International Nuclear Information System (INIS)

    Melendrez, R.; Pedroza M, M.; Chernov, V.; Ochoa N, J.D.; Bernal, R.; Barboza F, M.; Castaneda, B.; Goncalves, J.A.N.; Sandonato, G.M.; Cruz Z, E.; Preciado F, S.; Cruz V, C.; Brown, F.; Schreck, M.

    2004-01-01

    The diamond is a material that possesses extreme physical properties, such as its hardness to the radiation, its low chemical reactivity besides its equivalence to the human tissue, which qualify him as an ideal material for radiation dosimetry. In this work, it was studied the thermal and optically stimulated response (Tl and OSL) of polycrystalline diamond films grown by the technique of CVD pure and contaminated with Boron-carbon (B/C) with the intention of characterizing their efficiency like a dosemeter for radiation in a range of 0 - 3000 Gy. For the case of the films without impurities, the Tl curve presents four main peaks, two of them in an interval of temperatures of 150-200 C and other two additional around of 250-400 C. The dependence of the response of integrated Tl and that of OSL always maintained a lineal relationship with the exhibition dose up to 100 Gy. The behavior of the films contaminated with B/C (2000 - 20000 ppm) was established through experiments that involved the signal of OSL and their relationship with the Tl response. It was found that this processes are correlated, since the electrons caught in the traps of low temperature (50 - 250 C) of the Tl they are the electrons that recombining with more probability to provide the signal of OSL. According to these results it is possible to propose the diamond films as a good candidate for dosimetry to, using the traditional technique of Tl so much as well as the but recent of OSL. (Author)

  9. Response function study of a scintillator detector of NaI(Tl)

    International Nuclear Information System (INIS)

    Villa, Marcelo Barros; Costa, Alessandro Martins da

    2014-01-01

    In measurements of gamma rays with Nai (Tl) scintillator, the detectors output data are pulse height spectra, that corresponding to distorted information about the radiation source due to various errors associated with the crystal scintillation process and electronics associated, instead of power spectra photons. Pulse height spectra are related to the real power spectra by means of scintillator detector response function NaI (Tl). In this work, the response function for a cylindrical crystal of Nal (Tl) of 7,62 x 7,62 cm (diameter x length) was studied, by Monte Carlo method, using the EGSnrc tool to model the transport of radiation, combined with experimental measurements. An inverse response matrix, even with the energy of the square root, which transforms the pulse height spectrum of photon energy spectrum was obtained. The results of this transformation of pulse height spectrum for photon energy spectrum is presented, showing that the methodology employed in this study is suitable

  10. TL response of citrine samples for high-dose dosimetry

    International Nuclear Information System (INIS)

    Teixeira, Maria Ines; Caldas, Linda V.E.

    2011-01-01

    The possibility of using samples of Brazilian stones as quartz, amethyst, topaz, etc. for high-dose dosimetry has been studied in recent years at IPEN, using the thermoluminescence technique (TL). In this work, the TL properties of citrine samples were studied. They were exposed to different doses of gamma radiation ( 60 Co). The natural citrine stone was extracted from a mine in Minas Gerais state, Brazil; it is a tectosilicate ranked as one of three-dimensional structure, showing clear yellow to golden brown color. The natural citrine stone is classified as quartz (SiO 2 ), and it has a lower symmetry and more compact reticulum. The citrine stone samples were powdered, and the selected grains were mixed with Teflon in the proportion 2 (Teflon):1 (Citrine). The mixture was pressed and sintered for production of Citrine -Teflon pellets of 50 mg. The TL emission curve showed two peaks at 160 deg C and 220 deg C. To remove the TL peak (160 deg C) of the sintered citrine pellet glow curves, different thermal treatments were tested during several time intervals. The TL dose-response curve between 50 Gy and 100 kGy, the reproducibility of TL response and the lower detection dose were obtained. The preliminary results show that citrine may be useful for high-dose dosimetry. (author)

  11. Development of surgical gamma probes with TlBr semiconductors and CsI(Tl) scintillators crystals

    International Nuclear Information System (INIS)

    Costa, Fabio Eduardo da

    2006-01-01

    Radio guided surgery, using probes with radiation detectors, has been prominence in the medical area in the last decade. This technique consists in injecting a radioactive substance to concentrate in tumour and assist the localization during the surgical procedure. The radio guided surgeries allowing the identification of lymph node has revolutioned the behavior of tumour in initial stadium when are being spread by lymphatic way. The conditions imposed to the surgery due the proximity between some lymph nodes, demands of the probes, a small diameters and capacity of individual identification of these lymph nodes radiolabelled by a specific tracer. The international market supplies these probes with CdTe semiconductors and scintillators, but there is some time lack a promptly technical assistance in the Brazilian market. This work developed probes with national technology, using CsI(Tl) scintillators crystals and, in substitution to CdTe crystals semiconductors, the TlBr crystal, that is a new semiconductor detector in a world-wide development, with advantages in relation to the CdTe. Both crystals have been grown in IPEN. All the necessary electronics, specially, the preamplifier, that was also a restrictive factor for development of these types of probe in the country, have been developed with components found in the national market. Systematic measures of spatial resolution, spatial selectivity, maximum sensitivity and quality of the shielding have been carried the probes development. The results have shown that the probes, one with the CsI(Tl) crystal and another with TlBr semiconductor presented the requested performance in the international literature for radio guided probes. (author)

  12. La respuesta inmune antiviral

    OpenAIRE

    Sánchez de la Rosa, Rainel; Sánchez de la Rosa, Ernesto; Rodríguez Hernández, Néstor

    1998-01-01

    Se expone que los virus son parásitos intracelulares obligados, puesto que no tienen metabolismo propio; esto obliga al sistema inmune a poner en marcha sus mecanismos más especializados para reconocer y eliminar, tanto a los virus libres, como a las células infectadas. Se señala que las células presentadoras de antígenos, los linfocitos B y los T unidos al complejo mayor de histocompatibilidad, forman parte de la organización de la respuesta inmune antiviral; la inducción de esta respuesta c...

  13. Development of tailor-made silica fibres for TL dosimetry

    International Nuclear Information System (INIS)

    Bradley, D.A.; Abdul Sani, Siti F.; Alalawi, Amani I.; Jafari, S.M.; Noor, Noramaliza M.; Hairul Azhar, A.R.; Mahdiraji, Ghafour Amouzad; Tamchek, Nizam; Ghosh, S.; Paul, M.C.; Alzimami, Khalid S.; Nisbet, A.; Maah, M.J.

    2014-01-01

    The Ge dopant in commercially available silica optical fibres gives rise to appreciable thermoluminscence (TL), weight-for-weight offering sensitivity to MV X-rays several times that of the LiF dosimeter TLD100. The response of these fibres to UV radiation, X-rays, electrons, protons, neutrons and alpha particles, with doses from a fraction of 1 Gy up to 10 kGy, have stimulated further investigation of the magnitude of the TL signal for intrinsic and doped SiO 2 fibres. We represent a consortium effort between Malaysian partners and the University of Surrey, aimed at production of silica fibres with specific TL dosimetry applications, utilizing modified chemical vapour deposition (MCVD) doped silica–glass production and fibre-pulling facilities. The work is informed by defect and dopant concentration and various production dependences including pulling parameters such as temperature, speed and tension; the fibres also provide for spatial resolutions down to <10 µm, confronting many limitations faced in use of conventional (TL) dosimetry. Early results are shown for high spatial resolution (∼0.1 mm) single-core Ge-doped TL sensors, suited to radiotherapy applications. Preliminary results are also shown for undoped flat optical fibres of mm dimensions and Ge-B doped flat optical fibres of sub-mm dimensions, with potential for measurement of doses in medical diagnostic applications. - Highlights: • Optical fibres tailor-made for TL dosimetry. • Sensitive to diagnostic as well as therapy doses in medicine. • Preform and fibre pulling facilities. • Relative TL and EPR measurements

  14. TL sensitivity of CaSO4:Dy phosphor powder - effect of grinding

    International Nuclear Information System (INIS)

    Shastry, S.S.; Kher, R.K.

    1979-01-01

    Grinding of polycrystalline CaSO 4 :Dy phosphor to powder form induces lattice defects. Changes in thermoluminescence (TL) sensitivity due to variation in trap density in the bulk and on the surface of phosphor grains are studied using gamma and UV radiations. TL sensitivity to gamma increases with grinding time due to the contribution from the new bulk traps which are generated by grinding. The surface traps degrade with increase in grinding time resulting in a decrease in UV sensitivity. Results on regeneration of the TL sensitivity due to annealing at different temperatures are also included. (Auth.)

  15. Persistent luminescence, TL and OSL characterization of beta irradiated SrAl2O4:Eu2+, Dy3+ combustion synthesized phosphor

    International Nuclear Information System (INIS)

    Zúñiga-Rivera, N.J.; García, R.; Rodríguez-Mijangos, R.; Chernov, V.; Meléndrez, R.; Pedroza-Montero, M.; Barboza-Flores, M.

    2014-01-01

    The persistent luminescence (PLUM), thermoluminescence (TL) and optically stimulated luminescence (OSL) properties of strontium aluminates co-doped with Eu +2 and Dy +3 exposed to beta radiation is reported. The phosphor was synthesized by the combustion synthesis method employing a highly exothermic redox reaction between the metal nitrates [Al(NO 3 ) 3 , Sr(NO 3 ) 2 , Eu(NO 3 ) 3 and Dy(NO 3 ) 3 ] and organic fuel carbohydrazide (CH 6 N 4 O). The long decay PLUM emission, TL and OSL were measured as a function of beta radiation dose. A wide emission band centered at 510 nm (green) related to Eu 2+ ions and lattice defects were observed for the synthesized samples. The presence of a variety of defects and aggregates were responsible for the observed broad 100 °C peaked TL glow curve of the irradiated sample which is composed of several overlapped TL peaks. The existence of multiple trapping levels, with different trapping/detrapping probabilities, is behind the particular features for the PLUM, TL and OSL emissions. We conclude that in the SrAl 2 O 4 :Eu 2+ , Dy 3+ phosphors, the low temperature TL peaked around 30–75 °C is responsible for the PLUM emission and those around 100 °C were related to very stable trapping states which provide suitable radiation storage properties to be used as a PLUM/TL/OSL radiation phosphor

  16. Scintillation response of CsI: Tl crystal under neutron, gamma, alpha particles and beta excitations

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Maria da Conceicao Costa; Madi Filho, Tufic; Lopes, Valdir Maciel; Berretta, Jose Roberto; Cardenas, Jose Patricio Nahuel, E-mail: macoper@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Among the converters of X and gamma radiation in light photons, known as scintillators, the one which is the most efficient emits photons with a wavelength near 400 nm. Particularly, among them, the cesium iodine doped with thallium (CsI:Tl) crystal is that which matches better between the light emission spectrum (peak at 540 nm) and the quantum sensitivity curve of the photodiodes and CCD (Charge Coupled Device). This explains the renewed interest in using this crystal as scintillator. Although the CsI:Tl crystal is commercially available, its local development would give the possibility to obtain it in different geometric configurations and coupling. Moreover, there is a special interest in studying new conditions that will alter the properties of this crystal in order to achieve a optimal level of its functional characteristics. Having an efficient national scintillator with low cost is a strategic opportunity to study the response of a detector applied to different types of radiation. The crystal of cesium iodide activated with thallium (CsI:Tl) has a high gamma detection efficiency per unit volume. In this paper, the CsI:Tl crystal, grown by the vertical Bridgman technique in evacuated silica ampoules and with the purpose of use as radiation detectors, is described. To evaluate the scintillator, measures of the thallium distribution in the crystal volume were taken, with overall efficiency score. The scintillator response was studied through gamma radiation from sources of {sup 137}Cs, {sup 60}Co, {sup 22}Na, {sup 54}Mn, {sup 131}I and {sup 99m}Tc; the beta radiation from source of {sup 90}Sr/{sup 90}Y, alpha particles from {sup 241}Am source and the scintillator response to neutrons from Am/Be source. The energetic resolution for {sup 137}Cs gamma rays (662 keV) was 10%. The results showed the validity of using the CsI:Tl crystal developed in our laboratory, in many applications in the area of radiation detectors. (author)

  17. 201Tl heart studies

    International Nuclear Information System (INIS)

    Bell, R.L.

    1976-01-01

    At the annual meeting of the Society of Nuclear Medicine there was a preponderance of papers dealing with the heart. The most impressive papers detailed the use of monovalent cation 201 Tl in the evaluation of coronary artery disease. Thallium-201 behaves like potassium in that it enters heart muscle quickly and persists in that organ for several hours. It is unlike most radioactive potassium analogues used for heart studies in that: (1) its gamma energy peaks (69 keV and 80 keV) are more easily collimated with resultant image improvement, (2) its physical half life of 72 hours is sufficiently short to attain high counting rates without too much radiation and is sufficiently long so that storage is not prohibitive, (3) its short half life and lack of Beta radiation results in lower radiation to the patient, and (4) its uptake in heart is greater and uptake in liver and stomach less than other potassium analogues

  18. TL and ESR based identification of gamma-irradiated frozen fish using different hydrolysis techniques

    Science.gov (United States)

    Ahn, Jae-Jun; Akram, Kashif; Shahbaz, Hafiz Muhammad; Kwon, Joong-Ho

    2014-12-01

    Frozen fish fillets (walleye Pollack and Japanese Spanish mackerel) were selected as samples for irradiation (0-10 kGy) detection trials using different hydrolysis methods. Photostimulated luminescence (PSL)-based screening analysis for gamma-irradiated frozen fillets showed low sensitivity due to limited silicate mineral contents on the samples. Same limitations were found in the thermoluminescence (TL) analysis on mineral samples isolated by density separation method. However, acid (HCl) and alkali (KOH) hydrolysis methods were effective in getting enough minerals to carry out TL analysis, which was reconfirmed through the normalization step by calculating the TL ratios (TL1/TL2). For improved electron spin resonance (ESR) analysis, alkali and enzyme (alcalase) hydrolysis methods were compared in separating minute-bone fractions. The enzymatic method provided more clear radiation-specific hydroxyapatite radicals than that of the alkaline method. Different hydrolysis methods could extend the application of TL and ESR techniques in identifying the irradiation history of frozen fish fillets.

  19. Study of TL and optically stimulated luminescence of K{sub 2}Ca{sub 2}(SO{sub 4}){sub 3}:Cu nanophosphor for radiation dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Mandlik, Nandkumar [Department of Physics, University of Pune, Pune 411007 (India); Department of Physics, Ferguson College, Pune 411004 (India); Sahare, P.D. [Department of Physics and Astrophysics, University of Delhi, Delhi 110007 (India); Kulkarni, M.S. [Radiological Physics and Advisory Division, BARC, Mumbai 400085, Maharashtra (India); Bhatt, B.C. [Radiation Safety Systems Division, BARC, Mumbai 400085, Maharashtra (India); Bhoraskar, V.N. [Department of Physics, University of Pune, Pune 411007 (India); Dhole, S.D., E-mail: sanjay@physics.unipune.ac.in [Department of Physics, University of Pune, Pune 411007 (India)

    2014-02-15

    Nanocrytstalline K{sub 2}Ca{sub 2}(SO{sub 4}){sub 3}:Cu phosphor was synthesized by the chemical co-precipitation method and annealed at different temperatures (400–900 °C) for 2 h. The XRD spectrum shows the cubic structure with crystallite size ∼20 nm. The same was also confirmed from the TEM image which shows the formation of nanorods having diameter ∼20 nm and length of ∼200 nm. They are found to be quite uniform in shapes and sizes. These samples were irradiated with gamma radiation for the doses varying from 0.01 Gy to 10 kGy and their thermoluminescence (TL) characteristics and continuous wave optically stimulated luminescence (CW-OSL) have been studied. The sample annealed at 700 °C was found to be most sensitive than others. The glow curves of the nanophosphor show a major peak at around 175 °C and other two peaks of low intensity at around 85 °C and 305 °C. The traps responsible for the three thermoluminescence peaks in K{sub 2}Ca{sub 2}(SO{sub 4}){sub 3}:Cu are also found to be sensitive to the OSL. The qualitative correlation between TL peaks and CW-OSL response is established. The TL response of the sample annealed at 700 °C for 2 h and irradiated with different gamma doses shows a linear behavior from 0.01 up to 300 Gy and become sublinear in the range of 300 Gy–1 kGy before it saturates with further increase in the dose, while, the OSL response of the same sample shows linearity up to 1 kGy. Simple glow curve structure, easy method of synthesis, and linear dose response make the nanocrystalline phosphor a good candidate for radiation dosimetry, especially for the estimation of high doses of gamma rays where the microcrystalline phosphors generally saturate. -- Highlights: • Nanocrytstalline K{sub 2}Ca{sub 2}(SO{sub 4}){sub 3}:Cu phosphor was synthesized by the chemical co-precipitation method. • Thermoluminescence (TL) and continuous wave optically stimulated luminescence (CW-OSL) characteristics have been studied. • The TL glow

  20. Tl response of LiF:Mg, Cu, P + PTFE to Am-Be neutrons

    International Nuclear Information System (INIS)

    Gonzalez M, P.R.

    2000-01-01

    In different laboratories of the world it is followed the research about development of new Tl materials, whose main characteristics should be their equivalence with the tissue and their high sensibility to any type of radiation. The study consists in to measure the Tl peak intensity which TLD-100 presents at being irradiated with neutrons and that appears over 250 Centigrade, for compare it with the Tl intensity of the LiF: Mg, Cu, P + PTFE dosemeters. However, not all dosemeters of the same group show the interesting peak, by this only can be the total Tl intensity of dosemeters studied. In the ININ dosemeters development laboratory, we have developed a Tl material of lithium fluoride activated with magnesium, copper and phosphorus (LiF: Mg, Cu, P) that in polycrystalline powder form is almost 35 times more sensitive than the TLD-100 commercial dosemeter of Harshaw/Filtrol, USA. With the use of polytetrafluorethylene (PTFE) and with the above described Tl material, it has been possible to obtain dosemeters in pellet form of LiF: Mg, Cu, P + PTFE. (Author)

  1. Correlation between TL and OSL properties of CaF2:N

    International Nuclear Information System (INIS)

    Polymeris, George S.; Kitis, George; Tsirliganis, Nestor C.

    2006-01-01

    Natural CaF 2 is very well known thermoluminescent (TL) material, since it has been extensively used as a dosimeter. Its basic advantage is the exhibited high TL sensitivity. In the present work, the optically stimulated luminescence (OSL) sensitivity of this material was studied by exposing it to environmental radiation for time intervals of few hours up to a few days, and was found to be very high. By analyzing the TL glow curves and the OSL decay curves into their individual glow-peaks and components respectively, a relation between specific glow-peaks and OSL components was established. An intense thermal transfer effect occurring during optical stimulation at high temperature was observed and an explanation is offered according to existing models

  2. Identification of food preserved by ionizing radiation; Preliminary tests in strawberries using thermoluminescent (TL)

    International Nuclear Information System (INIS)

    Rubio, T.; Sillano, O.; Espinoza, J.; Roman, A.; Deza, A.

    1992-01-01

    TL measurements, of irradiated and unirradiated strawberries were carried out, using peel, seeds (achenes), leaves and sediment. The four types of samples presented a different thermoluminescence response. The best results were obtained with sediment removed from the soil of the fruit surface. It is concluded that TL is a promising technique for detecting irradiated strawberries using sediment samples. (author)

  3. Radiation damage of CsI(Tl) scintillators: blocking of energy transfer process of V sub k centers to Tl sup + activators

    CERN Document Server

    Hamada, M M; Shimizu, S; Kubota, S

    2002-01-01

    This paper reports the emission spectra, light output, transmission and decay curves of CsI(Tl) crystals irradiated with gamma rays at different doses, ranging from 1x10 sup 5 to 5x10 sup 5 Gy. The crystals were coated with black or white tapes. Significant decreases in the emission spectra and light output values were observed for the crystals coated with white tape as the radiation dose increased. The decrease in the degree of the rising part of the decay curve in the irradiated crystals is attributed to the blocking of the energy transfer processes of V sub k lattice disorders, which were produced in irradiated crystals. The scintillation mechanism is affected in the crystal irradiated at 5x10 sup 5 Gy. However for crystals irradiated below 10 sup 5 Gy the mechanism process is not altered, and the decrease in the light output is due to internal transmission loss. It was also observed that the damage for irradiation is not permanent and it obeys a bi-exponential function.

  4. TL transgenic mouse strains

    International Nuclear Information System (INIS)

    Obata, Y.; Matsudaira, Y.; Hasegawa, H.; Tamaki, H.; Takahashi, T.; Morita, A.; Kasai, K.

    1993-01-01

    As a result of abnormal development of the thymus of these mice, TCR αβ lineage of the T cell differentiation is disturbed and cells belonging to the TCR γδ CD4 - CD8 - double negative (DN) lineage become preponderant. The γδ DN cells migrate into peripheral lymphoid organs and constitute nearly 50% of peripheral T cells. Immune function of the transgenic mice is severely impaired, indicating that the γδ cells are incapable of participating in these reactions. Molecular and serological analyses of T-cell lymphomas reveal that they belong to the γδ lineage. Tg.Tla a -3-1 mice should be useful in defining the role of TL in normal and abnormal T cell differentiation as well as in the development of T-cell lymphomas, and further they should facilitate studies on the differentiation and function of γδ T cells. We isolated T3 b -TL gene from B6 mice and constructed a chimeric gene in which T3 b -TL is driven by the promoter of H-2K b . With the chimeric gene, two transgenic mouse strains, Tg. Con.3-1 and -2 have been derived in C3H background. Both strains express TL antigen in various tissues including skin. The skin graft of transgenic mice on C3H and (B6 X C3H)F 1 mice were rejected. In the mice which rejected the grafts, CD8 + TCRαβ cytotoxic T cells (CTL) against TL antigens were recognized. The recognition of TL by CTL did not require the antigen presentation by H-2 molecules. The results indicated that TL antigen in the skin becomes a transplantation antigen and behaves like a typical allogeneic MHC class I antigen. The facts that (B6 X C3H)F 1 mice rejected the skin expressing T3 b -TL antigen and induced CTL that killed TL + lymphomas of B6 origin revealed that TL antigen encoded by T3 b -TL is recognized as non-self in B6 mice. Experiments are now extended to analyze immune responses to TL antigen expressed on autochthonous T cell lymphomas. (J.P.N.)

  5. Solid solutions of thallium in TlGaSe2, TlGaS2, and TlInS2

    International Nuclear Information System (INIS)

    Voroshilov, Yu. V.; Potorii, M.V.; Shevchenko, S.V.

    1986-01-01

    The authors study the nature of the dissolution of thallium in ternary phases. They have synthesized alloys of the stoichiometric compositions TlGaS 2 , TlGaSe 2 , and T1InS 2 , and their solid solutions, maximally enriched in thallium, the compositions of which were Tl /SUB 1.34/ GA /SUB 0.89/ S 2 , Tl /SUB 1.31/ Ga /SUB 0.90/ Se 2 , and Tl /SUB 1.15/ In /SUB 0.95/ S /SUB 2./ . Samples were synthesized from the elemental components of the following purities: gallium of V4 grade; indium of V4 grade; thallium of T1000 grade; selenium of special purity 22-4 grade, and sulfur of special purity garde. The compositions were checked by x-ray-phase-(DRON-0.5) and microstructural-analyses with simultaneous determination of the density and microhardness of the samples. It is found that the lattic parameter increases and the increase in the density and microhardness points to strengthening of the structure during the formation of the solid solutions

  6. Measurement of low-LET radiation dose aboard the chinese scientific experiment satellite (1988) by highly sensitive LiF (Mg, Cu, P) TL chips

    International Nuclear Information System (INIS)

    Zhang Zhonglun; Zheng Yanzhen.

    1989-01-01

    Low-LET radiation dose is an important portion of spaceflight dose. It is a new application that highly sensitive LiF(Mg, Cu, P) TL chips are used in measurement of low-LET dose aboard the chinese scientific experiment satellite. Avarage dose rate in satellite is 9.2 mrad/day and on the ground is about 0.32 mrad/day

  7. Myocardial scintigraphy with 199Tl chloride for the assessment of antianginal effect of cardil

    International Nuclear Information System (INIS)

    Chernov, V.I.; Mordovin, V.F.; Vesnina, Zh.V.; Triss, S.V.; Bazilevich, I.A.; Lishmanov, Yu.B.

    1995-01-01

    The aim of this research was examination of myocardial perfusion in cardil therapy of twenty-two coronary patients and analysis of potentialities of load 199 Tl scintigraphy in assessment of the antianginal effect in the course of therapy of coronary patients. The findings evidence that due to short 199 Tl half life and low radiation load of the body because of this radionuclide load 199 Tl scintigraphy of the myocardium carried out in the course of therapy of coronary patients may be used as an objective test to assess myocardial perfusion under the effect of treatment. 8 refs

  8. Emission properties of thermoluminescence from natural quartz - blue and red TL response to absorbed dose

    International Nuclear Information System (INIS)

    Hashimoto, T.; Yokosaka, K.; Habuki, H.

    1987-01-01

    The TL spectrometry of natural quartz exposed to a gamma radiation dose of 8.8 kGy proved that the red TL, mainly from volcanically originated quartz, has a broad emission band with a peak around 620 nm, while the blue TL from plutonically originated quartz also has a broad emission band giving a peak around 470 nm. These typical red or blue intrinsic colours were also confirmed on the thermoluminescence colour images (TLCI). Exceptionally, a pegmatite quartz changed its TLCI colour from red to blue when the absorbed dose was increased. By using colour filter assemblies, all these quartz samples were shown to emit mainly blue and red TLs, which have distinctly different TL responses to the absorbed dose; the blue invariably showed a supralinearity relation between 1 and 10 kGy dose. For the purpose of dating, the use of red TL, is preferable. The red TL component is related to the impurity Eu content in quartz minerals. (author)

  9. Dose-rate and the reciprocity law: TL response of Ge-doped SiO2 optical fibers at therapeutic radiation doses

    International Nuclear Information System (INIS)

    Abdul Rahman, A.T.; Nisbet, A.; Bradley, D.A.

    2011-01-01

    An investigation has been made on commercially available Ge-doped SiO 2 optical fibers as a novel thermoluminescence system for radiotherapy dosimetry. This dosimeter has previously been shown by the group to provide sensitive dosimetry over a wide range of electron and photon dose, suitable for the needs of radiotherapy. In addition the optical fiber offers small physical size (125 μm diameter) and hence high spatial resolution. The reciprocity between thermoluminescence (TL) yield of Ge-doped SiO 2 optical fibers and dose has been investigated for fixed radiation dose for a range of photon and electron dose rates. For electron beams of nominal energies in the range of 9-20 MeV, we have investigated the TL response of these fibers for dose rates between 100 and 1000 cGy min -1 . For photon beams of nominal energies in the range of 6-15 MV, we have used dose rates of 100-600 cGy min -1 . Reproducibility and fading at fixed absorbed dose (3 Gy) and dose rate for the optical fibers were also investigated. At fixed dose rates, the TL optical fibers were found to produce a flat TL yield within 4% (1σ) and 3% (1σ) for electron and photon beams, respectively. The optical fibers demonstrated good reproducibility (±1.5%), low residual signal for a readout temperature of 300 o C and negligible fading. A weak dependence on dose-rate has been observed in the range of 3.4-3.9% for electrons (with an associated uncertainty of 4%) and 2.4-2.9% for photons (with an associated uncertainty of <4%). For electron and photon energies we note a consistent trend towards lower response in the TL yield of between 3.4-3.9% and 2.4-2.7%, respectively, at the higher dose rates in comparison with the response at lower dose rates. In addition we note an appreciable systematic energy dependence for both electron and photon beams. It is important to take such factors into account for providing precise and accurate radiotherapy dosimetry. It is also apparent that the optical fibers can be re

  10. Use of TL dosemeters for measuring doses of external gamma radiation in the vicinity of the Dukovany NPP

    International Nuclear Information System (INIS)

    Ohera, M.; Fiala, E.; Valasek, J.

    1992-01-01

    The results of measurement of the photon dose equivalent from external gamma radiation in the surroundings of the Dukovany nuclear power plant are given for 20 sites in southern Moravia over the 1984-1990 period, i.e., one year before starting up the plant and 6 years of its operation. CaSO 4 :Dy TL dosemeters were used, applying filtration with 0.5 mm Pb and 0.2 mm Pb + 0.6 mm Sn. Since 1989, the towns along the borders with Austria (Znojmo, Vranov, Mikulov) have been included, along with the Brno, Trebic, Zakrany, Ivancice and Jaromerice sites, into the national monitoring TL dosimetric network. The elevated doses at some sites come from the bedrock and are not caused by the operation of the plant. The effect of the Chernobyl accident on the dosemeter response is also evaluated. Comparison of the data prior to the Dukovany plant start-up (1984) and during the operation (1985-1990) give evidence that the operation of the power plant did not bring about any increase in the values monitored. (Z.S.). 3 tabs., 8 figs., 9 refs

  11. TL, EPR and optical absorption in natural grossular crystal

    Energy Technology Data Exchange (ETDEWEB)

    Yauri, J.M. [Institute of Physics, University of Sao Paulo, Rua do Matao, Travessa R, 187, CEP 05508-900, Sao Paulo (Brazil); Department of Physics, University of San Agustin, Av. Independencia S/N, Arequipa (Peru); Cano, N.F. [Institute of Physics, University of Sao Paulo, Rua do Matao, Travessa R, 187, CEP 05508-900, Sao Paulo (Brazil)], E-mail: nilocano@dfn.if.usp.br; Watanabe, S. [Institute of Physics, University of Sao Paulo, Rua do Matao, Travessa R, 187, CEP 05508-900, Sao Paulo (Brazil)

    2008-10-15

    Grossular is one of six members of silicate Garnet group. Two samples GI and GII have been investigated concerning their luminescence thermally stimulated (TL). EPR and optical absorption and the measurements were carried out to find out whether or not same point defects are responsible for all three properties. Although X-rays diffraction analysis has shown that both GI and GII have practically the same crystal structure of a standard grossular crystal, they presented different behavior in many aspects. The TL glow curve shape, TL response to radiation dose, the effect of annealing at high temperatures before irradiation, the dependence of UV bleaching parameters on peak temperature, all of them differ going from GI to GII. The EPR signals around g=2.0 as well as at g=4.3 and 6.0 have much larger intensity in GI than in GII. Very high temperature (>800 deg. C) annealing causes large increase in the bulk background absorption in GI, however, only very little in GII. In the cases of EPR and optical absorption, the difference in their behavior can be attributed to Fe{sup 3+} ions; however, in the TL case one cannot and the cause was not found as yet.

  12. TL, EPR and optical absorption in natural grossular crystal

    International Nuclear Information System (INIS)

    Yauri, J.M.; Cano, N.F.; Watanabe, S.

    2008-01-01

    Grossular is one of six members of silicate Garnet group. Two samples GI and GII have been investigated concerning their luminescence thermally stimulated (TL). EPR and optical absorption and the measurements were carried out to find out whether or not same point defects are responsible for all three properties. Although X-rays diffraction analysis has shown that both GI and GII have practically the same crystal structure of a standard grossular crystal, they presented different behavior in many aspects. The TL glow curve shape, TL response to radiation dose, the effect of annealing at high temperatures before irradiation, the dependence of UV bleaching parameters on peak temperature, all of them differ going from GI to GII. The EPR signals around g=2.0 as well as at g=4.3 and 6.0 have much larger intensity in GI than in GII. Very high temperature (>800 deg. C) annealing causes large increase in the bulk background absorption in GI, however, only very little in GII. In the cases of EPR and optical absorption, the difference in their behavior can be attributed to Fe 3+ ions; however, in the TL case one cannot and the cause was not found as yet

  13. Tl Cuprate Superconductors Studied by XPS

    Energy Technology Data Exchange (ETDEWEB)

    Vasquez, R. P. [Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109-8099 (United States); Siegal, M. P. [Sandia National Laboratories, Albuquerque, NM 87185-1421 (United States); Overmyer, D. L. [Sandia National Laboratories, Albuquerque, NM 87185-1421 (United States); Ren, Z. F. [Department of Chemistry, State University of New York, Buffalo, NY 14260-3000 (United States); Lao, J. Y. [Department of Chemistry, State University of New York, Buffalo, NY 14260-3000 (United States); Wang, J. H. [Department of Chemistry, State University of New York, Buffalo, NY 14260-3000 (United States)

    1999-07-01

    XPS measurements on epitaxial thin films of the Tl cuprate superconductors Tl2Ba2CaCu2O8, Tl2Ba2Ca2Cu3O10, and Tl0.78Bi0.22Ba0.4Sr1.6Ca2Cu3O9-{delta} are presented. These data, together with previous measurements in this lab on Tl2Ba2CuO6-{delta} and TlBa2CaCu2O7-{delta}, comprise a comprehensive data set for comparison of Tl cuprates in which the number of Tl-O and Cu-O layers, and hence the chemical and electronic properties, vary. (c) 2000 American Vacuum Society.

  14. Tl Cuprate Superconductors Studied by XPS

    International Nuclear Information System (INIS)

    Vasquez, R. P.; Siegal, M. P.; Overmyer, D. L.; Ren, Z. F.; Lao, J. Y.; Wang, J. H.

    1999-01-01

    XPS measurements on epitaxial thin films of the Tl cuprate superconductors Tl2Ba2CaCu2O8, Tl2Ba2Ca2Cu3O10, and Tl0.78Bi0.22Ba0.4Sr1.6Ca2Cu3O9-δ are presented. These data, together with previous measurements in this lab on Tl2Ba2CuO6-δ and TlBa2CaCu2O7-δ, comprise a comprehensive data set for comparison of Tl cuprates in which the number of Tl-O and Cu-O layers, and hence the chemical and electronic properties, vary. (c) 2000 American Vacuum Society

  15. (Tl, Sb) and (Tl, Bi) binary surface reconstructions on Ge(111) substrate

    Science.gov (United States)

    Gruznev, D. V.; Bondarenko, L. V.; Tupchaya, A. Y.; Yakovlev, A. A.; Mihalyuk, A. N.; Zotov, A. V.; Saranin, A. A.

    2018-03-01

    2D compounds made of Group-III and Group-V elements on the surface of silicon and germanium attract considerable attention due to prospects of creating III-V binary monolayers, which are predicted to hold advanced physical properties. In the present work, we have investigated two such systems, (Tl, Sb)/Ge(111) and (Tl, Bi)/Ge(111) using scanning tunneling microscopy, low energy electron diffraction observations and density-functional-theory calculations. In addition to the previously reported surface structures of 2D (Tl, Sb) and (Tl, Bi) compounds on Si(111), we found new ones, namely, √{ 7} × √{ 7} and 3 × 3. Formation processes and plausible models of their atomic arrangements are discussed.

  16. The response of different types of TL lithium fluoride detectors to high-energy mixed radiation fields

    Energy Technology Data Exchange (ETDEWEB)

    Obryk, B. [Institute of Nuclear Physics PAN (IFJ), ul. Radzikowskiego 152, 31-342 Krakow (Poland)], E-mail: barbara.obryk@ifj.edu.pl; Bilski, P.; Budzanowski, M. [Institute of Nuclear Physics PAN (IFJ), ul. Radzikowskiego 152, 31-342 Krakow (Poland); Fuerstner, M. [CERN - European Organization for Nuclear Research, 1211 Geneva 23 (Switzerland); Ilgner, C. [CERN - European Organization for Nuclear Research, 1211 Geneva 23 (Switzerland) and University of Dortmund, Dortmund (Germany); Jaquenod, F. [Ecole d' Ingenieurs de Geneve, Geneva (Switzerland); Olko, P.; Puchalska, M. [Institute of Nuclear Physics PAN (IFJ), ul. Radzikowskiego 152, 31-342 Krakow (Poland); Vincke, H. [CERN - European Organization for Nuclear Research, 1211 Geneva 23 (Switzerland)

    2008-02-15

    Thermoluminescent (TL) dosimeters are routinely used to monitor absorbed doses in many kinds of radiation fields which contain photons, electrons and neutrons. However, TLDs are mainly calibrated to photon sources. We studied the response of TLDs to complex secondary fields arising during the operation of high-energy accelerators (e.g. the Large Hadron Collider (LHC) at CERN). The experiments were conducted at the CERN-EU high-energy reference field facility (CERF). Six different LiF-based TLDs (MTS-N, MTS-7, MTS-6, MCP-N, MCP-7, MCP-6) were exposed to various secondary CERF's fields (both for high and low doses), by placing them at various positions: at the target and concrete top and side positions. For the experiment at the target the corresponding Monte Carlo calculations were also carried out using the FLUKA transport code and compared with experimental results. In addition, alanine dosimeters were used as an independent reference. The results show that TLDs are well suited for monitoring radiation fields around the LHC. Nevertheless, further investigations are required, some of which are in progress.

  17. TL sensitivity constancy of quartz upon UV+(β,γ) irradiation cycle: An improvement on dating methodology

    International Nuclear Information System (INIS)

    Souza, J.H.

    1985-01-01

    Thermoluminescence (TL) sensivitivy of natural quartz (beaches, paleobeaches and fixed dunes) to Beta and Gamma rays has been studied in a temperature range between 250-400 0 C, before and after bleaching by solar irradiation. A first TL glow growth curve was obtained through Beta irradiation of 'as found' samples and a second glow growth curve was obtained by bleaching through solar irradiation the TL acquired either through an excitation Gamma dose or through environmental radiation to finally re-irradiate the samples under Beta rays. Experimental results showing the constancy of sensitivity, for doses of until about 10K rads, are the basis for a proposal to improve TL dating methodology expanding its present limits. (Author) [pt

  18. TL and ESR based identification of gamma-irradiated frozen fish using different hydrolysis techniques

    International Nuclear Information System (INIS)

    Ahn, Jae-Jun; Akram, Kashif; Shahbaz, Hafiz Muhammad; Kwon, Joong-Ho

    2014-01-01

    Frozen fish fillets (walleye Pollack and Japanese Spanish mackerel) were selected as samples for irradiation (0–10 kGy) detection trials using different hydrolysis methods. Photostimulated luminescence (PSL)-based screening analysis for gamma-irradiated frozen fillets showed low sensitivity due to limited silicate mineral contents on the samples. Same limitations were found in the thermoluminescence (TL) analysis on mineral samples isolated by density separation method. However, acid (HCl) and alkali (KOH) hydrolysis methods were effective in getting enough minerals to carry out TL analysis, which was reconfirmed through the normalization step by calculating the TL ratios (TL 1 /TL 2 ). For improved electron spin resonance (ESR) analysis, alkali and enzyme (alcalase) hydrolysis methods were compared in separating minute-bone fractions. The enzymatic method provided more clear radiation-specific hydroxyapatite radicals than that of the alkaline method. Different hydrolysis methods could extend the application of TL and ESR techniques in identifying the irradiation history of frozen fish fillets. - Highlights: • Irradiation has potential to improve hygienic quality of raw and processed seafood. • Detection of irradiated food is important to enforce the applied regulations. • Different techniques were compared to separate silicate minerals from frozen fish. • Limitations were observed in TL analysis on minerals isolated by density separation. • Hydrolysis methods provided more clear identification using TL and ESR techniques

  19. Comparison of laboratory and in situ evaluation of environmental TL dosimeters

    International Nuclear Information System (INIS)

    Deme, S.; Apathy, I.; Feher, I.; Osvay, M.

    1996-01-01

    The passive environmental gamma-radiation dosimetry is mainly based on TL (thermoluminescent) dosimetry. This method offers considerable advantages due to its high precision, low cost, wide range, etc.. At the same time its application involves uncertainty caused by the dose collected during the transport from the point of annealing to the place of exposure and back to the place of evaluation. Should an accident occur read-out is delayed due to the need to transport to a laboratory equipped with a TLD reader. A portable reader capable of reading out the TL dosimeter at the place of exposure (in situ TLD reader) eliminates the disadvantages mentioned above. A microprocessor based portable TLD reader was developed by us for monitoring environmental gamma-radiation doses. Using a portable reader for in situ evaluation there are several disadvantages as well. The method requires the transport of the reader instead of dosimeters. The portable reader should be battery operated with low power consumption. Due to this requirement the temperature stabilization of the reader requests different solution as in laboratory type devices. Comparison of recently developed in situ and traditional laboratory evaluation methods of environmental TL dosimeters is given in recent paper. The comparison was made in the same conditions. The most characteristic - for environmental monitoring - numerical TL data (dose range, reproducibility, fading, self dose etc.) are given for manufactured by us CaSO 4 :Dy bulbs (portable reader) and very advantageous, high sensitive Al 2 O 3 :C dosimeters (laboratory evaluation). (author)

  20. Development of radiation detection and measurement system - Development of scintillation radiation sensor

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Hee Dong; Kim, Wan [Kyungpook National University, Taegu (Korea); Kim, Do Sung [Taegu University, Taegu (Korea)

    2000-03-01

    We have been fabricated CsI(Tl) scintillation crystals and plastic scintillators for radiation-based measuring equipment. CsI (Tl) single crystals doped with thallium as an activator were grown using the Czochralski method. The crystal structure of grown CsI(Tl) was bcc, and it was confirmed that its lattice constant was 4,568 A. The spectral range of luminescence of CsI(Tl) was 350 {approx} 700 nm independent of thallium concentration, and the fast component of the luminescence was decreased with increasing thallium concentration. The energy resolution of CsI(Tl) scintillator doped with 0.1 mole% thallium was about 9% for 137 Cs {gamma}-rays. The relation formula of {gamma}-ray energy versus energy resolution was ln(FWHM%)=-0.705ln({epsilon})+6.75. The radiation damage of CsI(Tl) increased in proportion to thallium concentration and radiation damage of CsI(Tl) increased in proportion to thallium concentration and radiation dosage, and the irradiated crystals were colored reddish. The radiation induced absorption bands appeared around 355, 425, 520 and 555 nm, and their energy level were about 3.50, 2.88, 2.39 and 2.21 eV. Plastic scintillators were fabricated thermal polymerization method. Those were polymerizing at 120 deg. C, during 72 hours, and annealing at 75 deg. C, during 24 hours. When the concentration of 1st solute was 1.5 wt% and concentration of 2nd solute was 0.01 wt%, the characteristics of scintillation were very excellent. Also 3.0 wt% tetraphenyl lead were loaded to improve the detection efficiency of {gamma}-ray. The range of emission spectrum was 400 {approx} 450nm, and the central peak was 415 nm. The radiation damage was not appear under 1*10{sup 3}Gy, but the color of plastic scintillator was changed to brown, over 1*10{sup 4}Gy exposured. 84 refs., 39 figs. (Author)

  1. Isotopic exchange in a neutron-irradiated mixed-valence compound: Tl3(I) Tl(III)Cl6

    International Nuclear Information System (INIS)

    Fernandez Valverde, S.; Duplatre, G.

    1977-01-01

    The initial distribution of Tl(I) and Tl(III) species, and its change on heating, have been investigated in solid thermal neutron-irradiated Th 4 Cl 6 . An initial ratio of 5/1 for 204 Tl(I)/ 204 Tl(III) is found and this remains constant for integral gamma-doses of 3 to 12 MRad. The variation of the 204 Tl(III) fraction with temperature is found identical to that observed in labelled Tl 4 Cl 6 for which a genuine isotopic exchange has previously been described. It is concluded that the recoil species are rapidly converted, after the recoil processes, into stable ions

  2. Dose-rate and the reciprocity law: TL response of Ge-doped SiO{sub 2} optical fibers at therapeutic radiation doses

    Energy Technology Data Exchange (ETDEWEB)

    Abdul Rahman, A.T., E-mail: a.t.abdulrahman@surrey.ac.uk [Centre for Nuclear and Radiation Physics, Department of Physics, University of Surrey, Guildford GU2 7XH, Surrey (United Kingdom); School of Physics and Material Studies, Faculty of Applied Sciences, Universiti Teknologi MARA Malaysia (UiTM), Campus of Negeri Sembilan, 72000 Kuala Pilah (Malaysia); Nisbet, A. [Centre for Nuclear and Radiation Physics, Department of Physics, University of Surrey, Guildford GU2 7XH, Surrey (United Kingdom); Departments of Medical Physics, the Royal Surrey County Hospital (RSCH) NHS Trust, Edgerton Road, Guildford GU2 7XX, Surrey (United Kingdom); Bradley, D.A. [Centre for Nuclear and Radiation Physics, Department of Physics, University of Surrey, Guildford GU2 7XH, Surrey (United Kingdom)

    2011-10-01

    An investigation has been made on commercially available Ge-doped SiO{sub 2} optical fibers as a novel thermoluminescence system for radiotherapy dosimetry. This dosimeter has previously been shown by the group to provide sensitive dosimetry over a wide range of electron and photon dose, suitable for the needs of radiotherapy. In addition the optical fiber offers small physical size (125 {mu}m diameter) and hence high spatial resolution. The reciprocity between thermoluminescence (TL) yield of Ge-doped SiO{sub 2} optical fibers and dose has been investigated for fixed radiation dose for a range of photon and electron dose rates. For electron beams of nominal energies in the range of 9-20 MeV, we have investigated the TL response of these fibers for dose rates between 100 and 1000 cGy min{sup -1}. For photon beams of nominal energies in the range of 6-15 MV, we have used dose rates of 100-600 cGy min{sup -1}. Reproducibility and fading at fixed absorbed dose (3 Gy) and dose rate for the optical fibers were also investigated. At fixed dose rates, the TL optical fibers were found to produce a flat TL yield within 4% (1{sigma}) and 3% (1{sigma}) for electron and photon beams, respectively. The optical fibers demonstrated good reproducibility ({+-}1.5%), low residual signal for a readout temperature of 300 {sup o}C and negligible fading. A weak dependence on dose-rate has been observed in the range of 3.4-3.9% for electrons (with an associated uncertainty of 4%) and 2.4-2.9% for photons (with an associated uncertainty of <4%). For electron and photon energies we note a consistent trend towards lower response in the TL yield of between 3.4-3.9% and 2.4-2.7%, respectively, at the higher dose rates in comparison with the response at lower dose rates. In addition we note an appreciable systematic energy dependence for both electron and photon beams. It is important to take such factors into account for providing precise and accurate radiotherapy dosimetry. It is also

  3. Measurement of conversion coefficients in 208Tl

    International Nuclear Information System (INIS)

    Wendling, F.

    1976-06-01

    A electron spectrometer composed by a Li drifted Si detector and a uniform magnetic field was constructed. The magnetic field is used to focus the electrons on the detector and to filter the other radiations. After the construction the instrument was calibrated in absolute eficience and was used together with a Ge(Li) spectrometer also calibrated, in the measurement of internal conversion coeficients of the 433 and 453 keV transitions in 208 Tl [pt

  4. Ab-Initio analysis of TlBr: limiting the ionic current without degrading the electronic one

    Science.gov (United States)

    Rocha Leao, Cedric; Lordi, Vincenzo

    2011-03-01

    Although TlBr in principle presents all the theoretical requirements for making high resolution room temperature radiation detectors, practical applications of TlBr have proven to be nonviable due to the polarization that is observed in the crystal after relatively short periods of operation. This polarization, that is believed to be caused by accumulation of oppositely charged ionic species at the ends of the crystal, results in an electric field that opposes that of the applied bias, counter-acting its effect. In this work, we use state of the art quantum modeling to benchmark the theoretical limits for the performance of TlBr as a radiation detector, showing that the best experimental reports demonstrate near-ideal electronic characteristics. We then propose a model to inhibit the detrimental ionic current in the material without impacting the excellent properties of the electronic current. Prepared by LLNL under Contract DE-AC52-07NA27344.

  5. Development of low background CsI(Tl) and NaI(Tl) crystals for WIMP search

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyun Su [Department of Physics, Ewha Womans University, Seoul 120-750 (Korea, Republic of)

    2015-08-17

    We have developed low background CsI(Tl) and NaI(Tl) crystals to search for weakly interacting massive particles as well as to verify the origin of the annual modulation signal observed by the DAMA/LIBRA experiment. Extensive studies about the contamination mechanisim of {sup 137}Cs in CsI powder lead to the growth of ultra-low-background CsI(Tl) crystals. Similar approaches for NaI(Tl) crystals have been applied to reduce internal backgrounds to less than 0.5 counts/kg/day/keV. Status and understanding of backgrounds and background reduction in NaI(Tl) crystals will be discussed.

  6. TL/OSL properties of natural schist for archaeological dating and retrospective dosimetry

    International Nuclear Information System (INIS)

    Afouxenidis, D.; Stefanaki, E.C.; Polymeris, G.S.; Sakalis, A.; Tsirliganis, N.C.; Kitis, G.

    2007-01-01

    Schist, a metamorphic rock composed largely of quartz and muscovite, has been used as a building stone through the centuries in many parts of the world. In ancient Greece, it was used in buildings and monuments (Knossos, Karthaia, etc). Basic TL and OSL properties of schist are studied in the present work to evaluate its potential use in archaeological dating and retrospective dosimetry. In particular, the optical stability, as well as the linearity of the TL and OSL signal were investigated for samples of natural schist obtained from a roofing slate. The results indicate that both signals are rapidly bleached when the sample is exposed to sunlight. An exposure of 1 min reduces the TL signal by 93%, the IRSL signal by 99% and the post-IR BSL signal by 90%. The dose response was found to be linear for a radiation dose at least up to 75 Gy for the TL and the IR OSL signal and at least up to 25 Gy for the post-IR BSL signal

  7. Persistent luminescence, TL and OSL characterization of beta irradiated SrAl{sub 2}O{sub 4}:Eu{sup 2+}, Dy{sup 3+} combustion synthesized phosphor

    Energy Technology Data Exchange (ETDEWEB)

    Zúñiga-Rivera, N.J. [Departamento de Física, Posgrado en Nanotecnología, Universidad de Sonora, Hermosillo, Sonora 83000 (Mexico); García, R.; Rodríguez-Mijangos, R.; Chernov, V.; Meléndrez, R.; Pedroza-Montero, M. [Departamento de Investigación en Física, Universidad de Sonora, Hermosillo, Sonora 83000 (Mexico); Barboza-Flores, M., E-mail: mbarboza@cifus.uson.mx [Departamento de Investigación en Física, Universidad de Sonora, Hermosillo, Sonora 83000 (Mexico)

    2014-05-01

    The persistent luminescence (PLUM), thermoluminescence (TL) and optically stimulated luminescence (OSL) properties of strontium aluminates co-doped with Eu{sup +2} and Dy{sup +3} exposed to beta radiation is reported. The phosphor was synthesized by the combustion synthesis method employing a highly exothermic redox reaction between the metal nitrates [Al(NO{sub 3}){sub 3}, Sr(NO{sub 3}){sub 2}, Eu(NO{sub 3}){sub 3} and Dy(NO{sub 3}){sub 3}] and organic fuel carbohydrazide (CH{sub 6}N{sub 4}O). The long decay PLUM emission, TL and OSL were measured as a function of beta radiation dose. A wide emission band centered at 510 nm (green) related to Eu{sup 2+} ions and lattice defects were observed for the synthesized samples. The presence of a variety of defects and aggregates were responsible for the observed broad 100 °C peaked TL glow curve of the irradiated sample which is composed of several overlapped TL peaks. The existence of multiple trapping levels, with different trapping/detrapping probabilities, is behind the particular features for the PLUM, TL and OSL emissions. We conclude that in the SrAl{sub 2}O{sub 4}:Eu{sup 2+}, Dy{sup 3+} phosphors, the low temperature TL peaked around 30–75 °C is responsible for the PLUM emission and those around 100 °C were related to very stable trapping states which provide suitable radiation storage properties to be used as a PLUM/TL/OSL radiation phosphor.

  8. Rare-earths influence in the thermoluminescent response of monoclinic ZrO{sub 2}; Influencia de tierras raras en la respuesta termoluminiscente de ZrO{sub 2} monoclinico

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza A, D.; Gonzalez M, P.R. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Vasquez L, M.J.; Rubio R, E. [Centro Universitario de Vinculacion, BUAP, 72000 Puebla (Mexico)

    2005-07-01

    Zirconium oxide (ZrO{sub 2}) with rare-earths (Nd, Dy, Eu and Y) as dopant were prepared by sol gel method and irradiated with gamma radiation. The thermoluminescent (TL) signal was studied as function of the impurities present for temperatures from 50 to 350 C. Pure ZrO{sub 2} produces a strong TL signal induced by gamma radiation, with a maximum located at 150 C, while ZrO{sub 2} doped with Nd, Dy and Y showed a TL signal with minor intensity, but with a maximum like to pure ZrO{sub 2}. However, when Eu is present as impurity the TL signal is much smaller than pure ZrO{sub 2}, with a maximum very enlarged. These results indicate that exits a strong influence of the rare-earths presents in the TL response and opens the possibility to control the TL signal in a wide range of dosages allowing to use these systems as a wide range dosimeter. Details of the thermoluminescent behavior of pure and doped ZrO{sub 2} will be discussed. (Author)

  9. The influence of nanoscale heterostructures on the thermoelectric properties of bi-substituted Tl{sub 5}Te{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Heinke, Frank; Schlegel, Robert; Schwarzmueller, Stefan; Oeckler, Oliver [Institute for Mineralogy, Crystallography, and Materials Science, Faculty of Chemistry and Mineralogy, Leipzig University (Germany); Eisenburger, Lucien [University of Munich (LMU), Department Chemie (Germany)

    2017-03-16

    Tl{sub 4.5}Bi{sub 0.5}Te{sub 3} crystallizes in a distorted variant of the Tl{sub 5}Te{sub 3} structure type in the space group I4/m. The symmetry reduction compared to Tl{sub 5}Te{sub 3} (space group I4/mcm) is a consequence of cation ordering as shown by resonant X-ray scattering using synchrotron radiation. Tl and Bi predominantly occupy one Wyckoff site each. This ordering is accompanied by displacements of Te atoms. The influence of nanostructuring on the thermoelectric performance of Tl{sub 4.5}Bi{sub 0.5}Te{sub 3} was investigated for the new composite model system Tl{sub 4.5}Bi{sub 0.5}Te{sub 3} - TlInTe{sub 2}. For the nominal composition (Tl{sub 4.5}Bi{sub 0.5}Te{sub 3}){sub 0.6}(TlInTe{sub 2}){sub 0.4}, the thermoelectric Figure of merit ZT reaches 0.8 at 325 C. Nanoscaled precipitates with sizes of about 100-200 nm probably have beneficial influence on the thermal conductivity at this temperature. (copyright 2017 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  10. TL dosimetric characterization of gamma irradiated SrSO{sub 4}:Eu phosphors

    Energy Technology Data Exchange (ETDEWEB)

    Jayasudha, S., E-mail: jsnair.india@gmail.com [Mahatma Gandhi College, Kesavadasapuram, Pattom Palace P.O., Thiruvananthapuram 695004 (India); Madhukumar, K.; Nair, C.M.K.; Nair, Resmi G. [Mahatma Gandhi College, Kesavadasapuram, Pattom Palace P.O., Thiruvananthapuram 695004 (India); Rajesh, S. [Department of Materials & Ceramic Engineering, University of Aveiro, Aveiro 3810-193 (Portugal); Elias, T.S. [State Institute of Cancer Research, Medical College P.O., Thiruvananthapuram 695011 (India); Anandakumar, V.M. [Mahatma Gandhi College, Kesavadasapuram, Pattom Palace P.O., Thiruvananthapuram 695004 (India); State Institute of Cancer Research, Medical College P.O., Thiruvananthapuram 695011 (India); Department of Materials & Ceramic Engineering, University of Aveiro, Aveiro 3810-193 (Portugal); Gopakumar, N. [Mahatma Gandhi College, Kesavadasapuram, Pattom Palace P.O., Thiruvananthapuram 695004 (India)

    2017-03-15

    Thermoluminescence (TL) characteristics of SrSO{sub 4}:Eu nanostructured phosphor under gamma excitation has been studied and their suitability for environmental radiation dosimetry applications is discussed. The dopant level is tuned for optimum TL response. The effect of radiation dose and heating rate were investigated. The phosphor preserves linearity in the low dose region, 0.1 Gy to 20 Gy. PL studies of irradiated and un-irradiated phosphors reveal that the dopant Eu exists in divalent state and are the luminescence emission centres in the material. The fading properties of SrSO{sub 4}:Eu phosphor are observed to be better than that of the commercial dosimeters TLD-200 and TLD-400. The kinetic parameters are calculated using Chen's method and initial rise method and verified by Computerized Glow curve Deconvolution (CGCD). The sensitivity of the synthesized phosphor is found to be very high when compared with that of the commercial standard dosimeter CaSO{sub 4}:Dy. The phosphor is found to be stable for short term radiation monitoring.

  11. Quality control 201TlCl solution obtained at IPEN-CNEN/SP through the direct method of 201Tl preparation

    International Nuclear Information System (INIS)

    Fernandes, L.; Silva, C.P.G. da.

    1991-09-01

    The radiopharmaceutical 201 TlCl is used in Nuclear medicine for myocardial visualization. The solution of 201 TlCl was prepared using 201 Tl obtained by irradiating a natural mercury target with protons. This radionuclide was subjected to different quality control processes to verify the purity required for its use in Medicine. Some of these controls concerned the determination of 200 Tl, 201 Tl and 202 Tl; the chemical identification of 201 Tl +1 ; the hydrazine concentration, mercury contamination and the presence of phosphate. Furthermore, the biologic distribution in Wistar rats and tests for sterility, pyrogens and for toxicity were carried out. It was verified that the solution obtained was in the form of thallous chloride. This radiopharmaceutical can give a good heart image in animals but due to the contamination of 201 Tl with 200 Tl and 202 Tl its use in human beings is not possible unless enriched 202 Hg is used as target of irradiation. (author)

  12. TL glow curve analysis of UV, beta and gamma induced limestone collected from Amarnath holy cave

    Directory of Open Access Journals (Sweden)

    Vikas Dubey

    2015-01-01

    Full Text Available The paper reports themoluminescence glow curve analysis of UV (ultraviolet, β (beta and γ (gamma induced limestone collected from Amarnath holy cave. The collected natural sample was characterized by X-ray diffraction (XRD technique and crystallite size calculated by Scherer's formula. Surface morphology and particle size was calculated by transmission electron microscopy (TEM study. Effect of annealing temperature on collected lime stone examined by TL glow curve study. The limestone was irradiated by UV radiation (254 nm source and the TL glow curve recorded for different UV exposure time. For beta irradiation Sr90 source was used and is shows intense peak at 256 °C with a shoulder peak at higher temperature range. For gamma radiation Co60 source and TL glow curve recorded for different doses of gamma. The kinetic parameters calculation was performed for different glow curve by computerized glow curve deconvolution (CGCD technique. The chemical composition of natural limestone was analyzed by energy dispersive X-ray spectroscopy (EDXS.

  13. Spectral measurements of loess TL

    International Nuclear Information System (INIS)

    Rendell, H.M.; Mann, S.J.; Townsend, P.D.

    1988-01-01

    Variations in thermoluminescence (TL) glow curves are reported for two loess samples when examined with broad band filters in the range 275-650 nm. Samples show striking differences in bleaching behaviour, when their TL emissions are observed in the u.v., blue, green and yellow spectral regions. The age estimates, given by the equivalent dose (ED) values, differ by up to a factor of two for analyses using the green and u.v. TL signals. These ED values also vary with prolonged room temperature storage between the bleaching and irradiation steps. The anomalies in the bleaching behaviour are interpreted in terms of changes in TL efficiency. The results have major implications for the regeneration method of TL dating for these fine-grained sediments and suggest that reliable dates obtained by it may be fortuitous. (author)

  14. 207Pb and 205Tl NMR on Perovskite Type Crystals APbX3 (A = Cs, Tl, X = Br, I)

    Science.gov (United States)

    Sharma, Surendra; Weiden, Norbert; Weiss, Alarich

    1987-11-01

    By 205Tl and 207Pb NM R the chemical shift in polycrystalline samples of binary halides AX, BX2 and ternary halides ABX3 (A = Cs, Tl; B = Pb; X = Br, I) was studied at room temperature. The chemical shift tensors δ ( 205Tl) and δ (207Pb) were determined in magnitude and orientation on single crystals of the orthorhombic TlPbI3. The components of the δ(205Tl) tensor are δx (205Tl) || a = 611ppm; δy (205Tl) || b = 680 ppm; δZ(205Tl) || c = 1329 ppm; δiso(205Tl) = 873.3 ppm (with respect to 3.4 molar aqueous solution of TlOOCCH3). The chemical shift tensor of 207Pb in TlPbI3 shows two orientations. One of them is: δx (207Pb) = 3760 ppm, inclined 30° from b towards c, δy(207Pb) || a = 3485 ppm, δz(207Pb) = 2639 ppm inclined 120° from b towards c. δiso(207Pb) = 3295 ppm (with respect to saturated aqueous solution of Pb(NO3)2). The results are discussed with respect to the crystal structure and a model to explain orientation and anisotropy of the tensors δ(205Tl) and δ(207Pb) in TlPbI3 is proposed. In the system CsPbBr3-x Ix δ(207Pb) was studied on polycrystalline samples. The chemical shift increases with increasing x and negative excess shift is observed.

  15. Calculation of the relative efficiency of thermoluminescent detectors to space radiation

    International Nuclear Information System (INIS)

    Bilski, P.

    2011-01-01

    Thermoluminescent (TL) detectors are often used for measurements of radiation doses in space. While space radiation is composed of a mixture of heavy charged particles, the relative TL efficiency depends on ionization density. The question therefore arises: what is the relative efficiency of TLDs to the radiation present in space? In the attempt to answer this question, the relative TL efficiency of two types of lithium fluoride detectors for space radiation has been calculated, based on the theoretical space spectra and the experimental values of TL efficiency to ion beams. The TL efficiency of LiF:Mg,Ti detectors for radiation encountered at typical low-Earth’s orbit was found to be close to unity, justifying a common application of these TLDs to space dosimetry. The TL efficiency of LiF:Mg,Cu,P detectors is significantly lower. It was found that a shielding may have a significant influence on the relative response of TLDs, due to changes caused in the radiation spectrum. In case of application of TLDs outside the Earth’s magnetosphere, one should expect lower relative efficiency than at the low-Earth’s orbit.

  16. TL and OSL properties of Mn2+-doped MgGa2O4 phosphor

    Science.gov (United States)

    Luchechko, A.; Zhydachevskyy, Ya; Maraba, D.; Bulur, E.; Ubizskii, S.; Kravets, O.

    2018-04-01

    The oxide MgGa2O4 spinel ceramics doped with Mn2+ ions was synthesized by a solid-state reaction at 1200 °C in air. The activator concentration was equal 0.05 mol% of MnO. Phase purity of the synthesized samples was analyzed by X-ray diffraction technique. This spinel ceramics show efficient green emission in the range from 470 to 550 nm with a maximum at about 505 nm under UV or X-ray excitations, which is due to Mn2+ ions. MgGa2O4: Mn2+ exhibits intense thermoluminescence (TL) and optically stimulated luminescence (OSL) after influence of ionizing radiation. Are complex nature of the TL glow curves is associated with a significant number of structural defects that are responsible for the formation of shallow and deep electron traps. In this work, time-resolved OSL characteristics of the samples exposed to beta particles are reported for the first time. A light from green LED was used for optical stimulation. Obtained TL and OSL results suggest MgGa2O4:Mn2+ as perspective material for further research and possible application in radiation dosimetry.

  17. Phase diagrams of novel Tl{sub 4}SnSe{sub 4}–TlSbSe{sub 2}–Tl{sub 2}SnSe{sub 3} quasi-ternary system following DTA and X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Barchiy, I.E.; Tatzkar, A.R. [Department of Chemistry, Uzhgorod National University, Pidgirna St., 46, Uzhgorod 88000 (Ukraine); Fedorchuk, A.O. [Department of Inorganic and Organic Chemistry, Lviv National University of Veterinary Medicine and Biotechnologies, Pekarska St., 50, Lviv 79010 (Ukraine); Plucinski, K., E-mail: kpluc2006@wp.pl [Electronics Department, Military University Technology, Warsaw, Kaliskiego 2, Warsaw 00-908 (Poland)

    2016-06-25

    Phase relation in the Tl{sub 4}SnSe{sub 4}–TlSbSe{sub 2}–Tl{sub 2}SnSe{sub 3} quasiternary system were studied by the DTA and X-ray diffraction in combination with mathematical modeling. The phase diagrams of the Tl{sub 4}SnSe{sub 4}–TlSbSe{sub 2} and Tl{sub 2}SnSe{sub 3}–TlSbSe{sub 2} systems, the perspective views of the phase interaction in the ternary system, the liquidus surface projection, the isothermal section at 423 K were built for the first time. The Tl{sub 4}SnSe{sub 4}–TlSbSe{sub 2}–Tl{sub 2}SnSe{sub 3} system is of the invariant eutectic type and is characterized by the formation of limited solid solutions following initial ternary compounds. New complex compounds are not formed. - Highlights: • Two Tl{sub 4}SnSe{sub 4}–TlSbSe{sub 2},Tl{sub 2}SnSe{sub 3}–TlSbSe{sub 2} systems were explored. • Invariant processes in the ternary system were determined. • New complex compounds were not observed in ternary system.

  18. Thallium (Tl) sorption onto illite and smectite: Implications for Tl mobility in the environment

    Science.gov (United States)

    Martin, Loïc A.; Wissocq, Aubéry; Benedetti, M. F.; Latrille, Christelle

    2018-06-01

    Clay minerals play a relevant role in the transport and fate of trace elements in the environment. Though illite has been referred as an important Thallium (Tl) bearing phase in soils, mechanisms and affinity of thallium for clay minerals remain poorly known. This study investigated the sorption behavior of thallium as Tl(I) onto illite and smectite, two clay minerals occurring mainly in soils and sediments. Different sorption experiments were carried out under various pH conditions and Tl concentrations, in competition with sodium and calcium at a constant ionic strength of 0.01 mol L-1. Our results showed that illite displayed more affinity than smectite for thallium. With illite, the distribution coefficients (Kd in L kg-1) varied between 102.75 ± 0.17 and 104.0 ± 0.17 in Na solutions versus between 102.25 ± 0.17 and 103.0 ± 0.17 in Ca solutions, depending on pH. With smectite, Kd (in L kg-1) ranged between 102.50 ± 0.16 and 103.20 ± 0.16 and between 101.25 ± 0.16 and 101.95 ± 0.16 in Na and Ca solutions, respectively. Sorption behavior was described with the Multi-Site Ion Exchanger model and selectivity coefficients with respect to protons were calculated for the first time. In all cases, independently of clay mineral and background electrolyte, low capacity but highly reactive sites were dominant in thallium uptake, highlighting Tl affinity for those sites. Moreover, the exchangeable and reversible interactions between Tl+ and clays reactive sites suggested that in changing conditions, thallium could be released in solution. The role of clay minerals in thallium environmental cycle is evident and confirmed illite to be a dominant Tl bearing phase, in some environment competing with manganese oxides. Compared to others Tl bearing mineral phases, clays are ranked as follows: MnO2 > illite > smectite ∼ ferrihydrite ≥ Al2O3 ∼ goethite > SiO2. Finally, over the three monovalent cations (Tl, Rb, Cs) Tl is the one less sorbed on illite independently of

  19. Development of a TL personal dosimeter identifiable PA exposure, and comparison with commercial TL dosimeters

    International Nuclear Information System (INIS)

    Kwon, J.W.; Kim, H.K.; Lee, J.K.; Kim, J.L.

    2004-01-01

    A single-dosimeter worn on the anterior surface of the body of a worker was found to significantly underestimate the effective dose to the worker when the radiation comes from the back. Several researchers suggested that this sort of underestimation can be corrected to a certain extent by using an extra dosimeter on the back. However, use of multiple dosimeters also has disadvantages such as complication in control or incurrence of extra cost. Instead of the common multi-dosimeter approach, in this study, a single dosimeter introducing asymmetric filters which enabled to identify PA exposure was designed, and its dose evaluation algorithm for AP-PA mixed radiation fields was established. A prototype TL personal dosimeter was designed and constructed. The Monte Carlo simulations were utilized in the design process and verified by experiments. The dosimeter and algorithm were applicable to photon radiation having an effective energy beyond 100 keV in AP-PA mixed radiation fields. A simplified performance test based on ANSI N13.11 showed satisfactory results. Considering that the requirements of the International Electrotechnical Commission (IEC) and the American National Standards Institute (ANSI) with regard to the dosimeter on angular dependency is reinforced, the dosimeter and the dose evaluation algorithm developed in this study provides a useful approach in practical personal dosimetry against inhomogeneous high energy radiation fields. (author)

  20. Quality control of the solution sup(201)TlCl obtained at IPEN-CNEN/SP by sup(201)Tl direct preparation

    International Nuclear Information System (INIS)

    Fernandes, L.; Silva, C.P.G. da

    1991-01-01

    The radiopharmaceutical sup(201) TlCl is used in Nuclear Medicine for myocardial visualization. The solution of sup(201)TlCl was prepared using sup(201)Tl obtained by irradiating a natural mercury target with protons. This radionuclide was subjected to different quality control processes to verify the purity required for its use in Medicine. Some of these controls concerned the determination of sup(200)Tl, sup(201)Tl and sup(202)Tl; the chemical identification of sup(201)Tl sup(+1); the hydrazine concentration, mercury contamination and the presence of phosphate. Furthermore, the biologic distribution in Wistar rats and tests for sterility pyrogens and for toxicity were carried out. It was verified that the solution obtained was in the form of tallous chloride. This radiopharmaceutical can give a good heart image in animals but due to the contamination of sup(201)Tl with sup(200)Tl and sup(202)Tl its use in human beings is not possible unless enriched sup(202)Hg is used as target of irradiation. (author)

  1. TL dosimetric properties BAM:EU

    International Nuclear Information System (INIS)

    Rao, Bellam N.; Murthy, K.V.R.; Subba Rao, B.; Saiprasad, A.S.

    2011-01-01

    In phosphor area today top priority is the replacement of the high performance but very expensive rare earth activated phosphors with cheaper materials. This essentially means replacing the rare earth ions with transition metal ions or post transition ions. Now a day's phosphors are used in various fields. After World War II, the advances in the optical spectroscopy of solids, especially those of transition metals ions help to evolve research on phosphor and solid state luminescence. In 1960 efficient rare earth activated phosphors were developed for use in color TV (Tb 3+ green, Eu 3+ red, and Dy 3+ yellow). In 1970 tricolor lamp was introduced blue emission from Ce 3+ + Tb 3+ pair was used in tricolor lamps. At present combination of halo phosphor and tri-band phosphor blend is used in many lamp as a compromise between performance, phosphor cost and the lamp making Cost. Thermo luminescence of 0.5 Gy X-ray irradiated BAM.Eu has been studied. The irradiated phosphor has been studied for its TL dosimetric properties one week after irradiation and after 100 weeks of storage. Interesting TL results are reported in the present paper. Heating rate used in the present experiment is 6.6 deg C/Sec. The following two figures are on TL recorded 100 weeks after irradiation and TL recorded after 235 weeks of storage. Before storage for 100 weeks the TL glow curve with a hump around 180 deg C followed by a peak at 273 deg C. After storage for 100 weeks the TL pattern changes entirely. i.e. the composite TL peak structure emerged as two well resolved peaks and with slightly higher TL peak temperatures at 215 deg C and 300 deg C. Normally after storage for 100 weeks the peak at 190 deg C reduces in its intensity or disappears in some cases, instead of that the peak appears at 215 deg C as well resolved peak and its intensity is almost comparable to that of 300 deg C peak. Since the TL phenomenon observed is interesting the two well resolved, isolated, high intensity peaks

  2. Tl response of LiF: Mg, Cu, P + PTFE (Mexico) and GR200A (China) dosemeters

    International Nuclear Information System (INIS)

    Gonzalez M, P.R.; Azorin N, J.; Furetta, C.

    2003-01-01

    TLD-100 was the commercial dosemeter more known since some decades ago. This dosemeter was considered for many research groups as the reference material for developing new Tl materials for ionizing radiation dosimetry. Actually it seems that TLD-100 is going to be replaced by the Chinese material GR200A, as reference material due that this material in addition to be considered as a tissue equivalent material, is 30 to 35 times more sensitive that TLD- 100. Results of the study of the Tl response of LiF: Mg, Cu, P + Ptfe developed at ININ-Mexico, comparing them with those of GR200A are presented. These results showed that the sensitivity (s = Tl intensity/weight x dose) to gamma radiation of the LiF: Mg, Cu, P + Ptfe dosimeters was 4.34 meanwhile that of the commercial dosemeter was 3.41. Detection threshold of the dosemeters studied was 2.22 and 0.52 μGy respectively Repeatability after 10 cycles Irradiation-reading-annealing was ±1.39% and ±1.86% respectively. Both types of dosemeters presented a linear response as a function of gamma radiation in the range from 0.02 mGy and 100 Gy. (Author)

  3. Prolate yrast cascade in 183Tl

    International Nuclear Information System (INIS)

    Reviol, W.; Carpenter, M. P.; Janssens, R. V. F.; Jenkins, D.; Toth, K. S.; Bingham, C. R.; Riedinger, L. L.; Weintraub, W.; Cizewski, J. A.; Lauritsen, T.

    2000-01-01

    The yrast sequence in 183 Tl has been studied for the first time in recoil-mass selected γ-ray spectroscopic measurements. A rotational-like cascade of seven transitions is established down to the band head with probable spin and parity (13/2 + ). Unlike in the adjacent odd-mass Tl nuclei, prompt γ decay from the yrast band to a lower lying weakly deformed (oblate) structure is not observed. These features are consistent with the predicted drop of the prolate band head in 183 Tl compared to 185 Tl. The implications for the prolate energy minimum in odd-mass Tl nuclei at the neutron i 13/2 midshell (N=103) are discussed. (c) 2000 The American Physical Society

  4. ESR and TL studies of irradiated Anatolian laurel leaf (Laurus nobilis L.)

    Science.gov (United States)

    Tepe Çam, Semra; Aydaş, Canan; Engin, Birol; Rabia Yüce, Ülkü; Aydın, Talat; Polat, Mustafa

    2012-06-01

    Laurel leaf (Laurus nobilis L.) samples that originated from Turkey were analyzed by electron spin resonance (ESR) and thermoluminescence (TL) techniques before and after γ-irradiation. Unirradiated (control) laurel leaf samples exhibit a weak ESR singlet centered at g=2.0020. Besides this central signal were two weak satellite signals situated about 3 mT left and right to it in radiation-induced spectra. The dose-response curve of the radiation-induced ESR signal at g=2.0187 (the left satellite signal) was found to be described well by a power function. Variation of the left satellite ESR signal intensity of irradiated samples at room temperature with time in a long term showed that cellulosic free radicals responsible for the ESR spectrum of laurel leaves were not stable but detectable even after 100 days. Annealing studies at four different temperatures were used to determine the kinetic behavior and activation energy of the radiation-induced cellulosic free radicals responsible from the left satellite signal (g=2.0187) in laurel leaves. TL measurements of the polymineral dust isolated from the laurel leaf samples allowed distinguishing between irradiated and unirradiated samples.

  5. Evaluation of 1cm dose equivalent rate using a NaI(Tl) scintilation spectrometer

    International Nuclear Information System (INIS)

    Matsuda, Hideharu

    1990-01-01

    A method for evaluating 1 cm dose equivalent rates from a pulse height distribution obtained by a 76.2mmφ spherical NaI(Tl) scintillation spectrometer was described. Weak leakage radiation from nuclear facilities were also measured and dose equivalent conversion factor and effective energy of leakage radiation were evaluated from 1 cm dose equivalent rate and exposure rate. (author)

  6. γ radiation thermoluminescence performance of HFCVD diamond films

    International Nuclear Information System (INIS)

    Gastelum, S.; Cruz-Zaragoza, E.; Melendrez, R.; Chernov, V.; Barboza-Flores, M.

    2006-01-01

    Polycrystalline chemically vapor deposited (CVD) diamond films have been proposed as detectors and dosimeters of ionizing radiation with prospective applications in high-energy photon dosimetry applications. We present a comparison study on the thermoluminescence (TL) properties of two diamond film samples grown by the hot filament CVD method having thickness of 180 and 500 μm and exposed to γ radiation in the 1-300 Gy dose range. The 180 μm thick sample deposited on silicon substrate displayed a TL glow curve peaked at 145 deg. C. The 500 μm, which was a free standing sample, exhibited higher intensity and a well defined first order kinetics TL glow peak around 289 deg. C. Both diamond samples showed a linear dose behavior in the 1-50 Gy range and sublinear behavior for higher doses. The 180 and 500 μm samples presented about 80% and 30% TL losses in a 24 h period, respectively, with both samples showing excellent TL reproducibility. The results indicate that the 500 μm CVD diamond film exhibited a good TL behavior adequate for γ radiation dosimetry

  7. Intercomparison of Environmental Dosemeters Using Various TL Materials and Dosimetry Systems

    International Nuclear Information System (INIS)

    Crnic, B.; Gobec, S.; Zorko, B.; Knezevic, Z.; Majer, M.; Ranogajec-Komor, M.

    2013-01-01

    The aim of the present work was to compare the ambient dose equivalent (H*(10)) values determined at 20 sites around NPP Krško, using different thermoluminescence (TL) materials and various dosimetry systems. The H*(10) was measured by the CaF 2 :Mn (TLD-400) provided by the Jozef Stefan Institute (JSI) Ljubljana, Slovenia. These dosemeters were deployed in the environment in plastic bags and suspended inside the plastic bottles. On the other hand the Ruder Boskovic Institute (RBI), Zagreb, Croatia applied LiF:Mg,Cu,P (TLD-100H), CaF 2 :Mn, Al 2 O 3 :C TL detectors and radiophotoluminescence (RPL) glass dosemeters type SG1. They were placed at the same locations in as much as possible same conditions as JSI detectors. According to the protocol established for this intercomparison, the control and transport detectors (not deployed in the environment) were held in dark storage containers and used to determine the background radiation. The TL responses were corrected for individual sensitivity of the TL detectors which is an important factor after the calibration irradiations. The calibration irradiations were performed by 137Cs sources provided in Secondary Standard Dosimetry Laboratory facilities at the JSI and RBI. The results obtained by different TL materials and different dosimetry systems show interesting features especially concerning local environmental peculiarities. The H*(10) obtained by the dosemeters of various types deployed in the countryside fluctuate less than 10 %. The outcome should emphasize also in the manner that the results obtained and reported in the intercomparison are traceable to the primary standards.(author)

  8. Radiation loss of planar surface plasmon polaritons transmission lines at microwave frequencies.

    Science.gov (United States)

    Xu, Zhixia; Li, Shunli; Yin, Xiaoxing; Zhao, Hongxin; Liu, Leilei

    2017-07-21

    Radiation loss of a typical spoof surface plasmon polaritons (SSPPs) transmission line (TL) is investigated in this paper. A 325 mm-long SSPPs TL is designed and fabricated. Simulated results show that radiation loss contributes more to transmission loss than dielectric loss and conductor loss from 2 GHz to 10 GHz. Radiation loss of the SSPPs TL could be divided into two parts, one is caused by the input mode converter, and the other is caused by the corrugated metallic strip. This paper explains mechanisms of radiation loss from different parts, designs a loaded SSPPs TL with a series of resistors to absorb electromagnetic energy on corrugated metallic strip, and then discriminates radiation loss from the input mode converter, proposes the concept of average radiation length (ARL) to evaluate radiation loss from SSPPs of finite length, and concludes that radiation loss is mainly caused by corrugated structure of finite length at low frequency band and by the input mode converter at high frequency band. To suppress radiation loss, a mixed slow wave TL based on the combination of coplanar waveguides (CPWs) and SSPPs is presented. The designed structure, sample fabrication and experimental verification are discussed.

  9. Recent advances in Tl Br, Cd Te and CdZnTe semiconductor radiation detectors: a review

    International Nuclear Information System (INIS)

    Oliveira, Icimone B.

    2011-01-01

    The success in the development of radiation spectrometers operating at room temperature is based on many years of effort on the part of large numbers of workers around the world. These individuals have contributed to the understanding of the fundamental materials issues associated with the growth of semiconductors for this application, the development of device fabrication and processing technology, and advances in low noise electronics and pulse processing. Progress in this field continues at an accelerated pace, as in evidenced by the improvements in detector performance and by the growing number of commercial products. Thus, the last years have been seen continued effort in the development of room temperature compound semiconductors devices. High-Z compound semiconductor detectors has been explored for high energy resolution, high detection efficiency and are of low cost. Compound semiconductors detectors are well suited for addressing needs of demanding applications such as bore hole logging where high operating temperature are encountered. In this work recent developments in semiconductors detectors were reviewed. This review concentrated on thallium bromide (TlBr), cadmium zinc telluride (CdZnTe) and cadmium telluride (CdTe) crystals detectors. TlBr has higher stopping power compared to common semiconductor materials because it has the higher photoelectric and total attenuation coefficients over wide energy range from 100 keV to 1 MeV. CdTe and CdZnTe detectors have several attractive features for detecting X-ray and low energy gamma ray. Their relatively large band gaps lead to a relatively low leakage current and offer an excellent energy resolution at room temperature. A literature survey and bibliography was also included. (author)

  10. Recent advances in Tl Br, Cd Te and CdZnTe semiconductor radiation detectors: a review

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Icimone B. [Universidade Bandeirante (UNIBAN), Sao Paulo, SP (Brazil)

    2011-07-01

    The success in the development of radiation spectrometers operating at room temperature is based on many years of effort on the part of large numbers of workers around the world. These individuals have contributed to the understanding of the fundamental materials issues associated with the growth of semiconductors for this application, the development of device fabrication and processing technology, and advances in low noise electronics and pulse processing. Progress in this field continues at an accelerated pace, as in evidenced by the improvements in detector performance and by the growing number of commercial products. Thus, the last years have been seen continued effort in the development of room temperature compound semiconductors devices. High-Z compound semiconductor detectors has been explored for high energy resolution, high detection efficiency and are of low cost. Compound semiconductors detectors are well suited for addressing needs of demanding applications such as bore hole logging where high operating temperature are encountered. In this work recent developments in semiconductors detectors were reviewed. This review concentrated on thallium bromide (TlBr), cadmium zinc telluride (CdZnTe) and cadmium telluride (CdTe) crystals detectors. TlBr has higher stopping power compared to common semiconductor materials because it has the higher photoelectric and total attenuation coefficients over wide energy range from 100 keV to 1 MeV. CdTe and CdZnTe detectors have several attractive features for detecting X-ray and low energy gamma ray. Their relatively large band gaps lead to a relatively low leakage current and offer an excellent energy resolution at room temperature. A literature survey and bibliography was also included. (author)

  11. Tl, Bi, and Pb doping in Ba4BiPb2TlO12-δ

    International Nuclear Information System (INIS)

    Sutto, T.E.; Averill, B.A.

    1992-01-01

    To determine the effects of different 6s metal concentrations on the superconducting nature of Ba 4 BiPb 2 TlO 12-δ , materials produced via four doping schemes were examined: Ba 4 Bi(Pb, Tl) 3 O 12-δ , Ba 4 -(BiPb) 3 TlO 12-δ , Ba 4 (Bi,Tl) 2 Pb 2 O 12-δ , and Ba 4 Bi x Pb 4-2x Tl x O 12-δ . For the parent compound a value of δ = 0.91 was observed, indicating that approximately 1/4 oxygen atom was missing per cubic subsection of the unit cell. For all samples, the symmetry of the parent compound changed from orthorhombic to tetragonal as the system moved away from the ideal composition. This was usually accompanied by the loss of superconductivity, which exhibited a maximum T c of 10.5 K for the parent compound Ba 4 BiPb 2 TlO 12-δ . Also reported are high-temperature magnetic susceptibility results, which are used to determine the effect of metal substitution on the density of states at the Fermi level. For each set of variants on the parent composition, the onset of superconductivity was accompanied by a significant decrease in the size of the Pauli paramagnetic signal. 16 refs., 6 figs

  12. Progress in TL Dating at Risø

    DEFF Research Database (Denmark)

    Mejdahl, V.

    1972-01-01

    This article outlines the thermoluminescent dating technique employed at Risö. The intensity of beta and gamma radiation is determined by means of the TL phosphors CaSO4:Mn and CaSO4:Dy, and the determination of accumulated exposure is based on quartz and feldspar inclusions with a size of 0.......3–0.5 mm. Results are presented of a dating programme comprising sherds, bricks, burned stones and burned clay (from kilns) from seventeen excavation sites. The age of the sites ranged from a.d. 1600 to 4000 b.c....

  13. Ultraviolet radiation dosimetry using CaF2 TL phosphors- state of the art

    International Nuclear Information System (INIS)

    Nagpal, J.S.

    2001-01-01

    Photoluminescence (PL), optical absorption (OA) and thermoluminescence (TL) of undoped and Dy, Tb- and Eu activated CaF 2 TL phosphors has been re-investigated after heat treatment (600-1100 degC) in air. The study confirmed the earlier observed increase in intrinsic UV response of CaF 2 : Dy 3+ after 900 degC heat treatment. Enhancement in UV response was also observed in undoped CaF 2 thus indicating the base matrix related phenomenon. However, the enhancement observed in UV sensitivity and the optimum treatment temperature for high UV sensitivity is different for different activators. It is activator specific and needs further probing. UV response of undoped CaF 2 monotonically increases as the treatment temperature (in air) is increased from 600 degC to 1100 degC. Similar increase is observed in case of CaF 2 : Tb 3+ also. However, CaF 2 : Dy 3+ and CaF 2 :Eu 2+ follow a different pattern. Heat treatment in air increases UV response of CaF 2 : Dy 3+ up to 900 degC, and a decrease is observed at higher temperatures. UV response of CaF 2 : Eu 2+ is maximum for 600 degC treatment in air and decreases thereafter. TL response of CaF 2 : Tb and CaF 2 : Eu 2+ phosphors to UV is high, can be employed over the range 10 -2 - 2 mJ.cm -2 and is rate independent for 250±10 nm UV. (author)

  14. Activation analysis of thallium in urine using the 203Tl(n,2n) 202Tl reaction

    International Nuclear Information System (INIS)

    Korob, R.O.; Cohen, I.M.; Lage, M.; Baro, G.B.

    1976-04-01

    The method developed by the authors of thallium determination in human urine, based on the 203 Tl(n,2n) 202 Tl reaction followed by chemical separation and measurement of the produced 202 Tl by gamma spectrometry, is described. Its application in some cases of intoxication by thallium is reported. The advantages and limitations of the described technique are discussed. (author) [es

  15. Thermal and x-ray studies on Tl2U(MoO4)3 and Tl4U(MoO4)4

    International Nuclear Information System (INIS)

    Dahale, N.D.; Keskar, Meera; Kulkarni, N.K.; Singh Mudher, K.D.

    2006-01-01

    In the quaternary Tl-U(IV)-Mo-O system, two new compounds namely Tl 2 U(MoO 4 ) 3 and Tl 4 U(MoO 4 ) 4 were prepared and characterized by powder X-ray diffraction and thermal methods. These compounds were prepared by solid state reactions of Tl 2 MoO 4 , UMoO 5 and MoO 3 in the required stoichiometric ratio at 500 deg C in evacuated sealed quartz ampoule. The XRD data of Tl 2 U(MoO 4 ) 3 and Tl 4 U(MoO 4 ) 4 were indexed on orthorhombic cell. TG curves of Tl 2 U(MoO 4 ) 3 and Tl 4 U(MoO 4 ) 4 did not show any weight change up to 700 deg C in an inert atmosphere. During heating in an inert atmosphere, Tl 2 U(MoO 4 ) 3 and Tl 4 U(MoO 4 ) 4 showed endothermic Dta peaks due to melting of the compounds at 519 and 565 deg C, respectively. (author)

  16. Review of doped silica glass optical fibre: Their TL properties and potential applications in radiation therapy dosimetry

    International Nuclear Information System (INIS)

    Bradley, D.A.; Hugtenburg, R.P.; Nisbet, A.; Abdul Rahman, Ahmad Taufek; Issa, Fatma; Mohd Noor, Noramaliza; Alalawi, Amani

    2012-01-01

    Review is made of dosimetric studies of Ge-doped SiO 2 telecommunication fibre as a 1-D thermoluminescence (TL) system for therapeutic applications. To-date, the response of these fibres has been investigated for UV sources, superficial X-ray beam therapy facilities, a synchrotron microbeam facility, electron linear accelerators, protons, neutrons and alpha particles, covering the energy range from a few eV to several MeV. Dosimetric characteristics include, reproducibility, fading, dose response, reciprocity between TL yield and dose-rate and energy dependence. The fibres produce a flat response to fixed photon and electron doses to within better than 3% of the mean TL distribution. Irradiated Ge-doped SiO 2 optical fibres show limited signal fading, with an average loss of TL signal of ∼0.4% per day. In terms of dose response, Ge-doped SiO 2 optical fibres have been shown to provide linearity to x and electron doses, from a fraction of 1 Gy up to 2 kGy. The dosimeters have also been used in measuring photoelectron generation from iodinated contrast media; TL yields being some 60% greater in the presence of iodine than in its absence. The review is accompanied by previously unpublished data. - Highlights: ► We review our TLD studies of Ge-doped SiO 2 fibres for therapeutic applications. ► Sources include UV, X-rays, protons, neutrons and alpha particles. ► These TLDs have also been used to measure photoelectrons from I 2 contrast media. ► The review is accompanied by previously unpublished data.

  17. Emergence of topological and topological crystalline phases in TlBiS2 and TlSbS2

    KAUST Repository

    Zhang, Qingyun

    2015-02-11

    Using first-principles calculations, we investigate the band structure evolution and topological phase transitions in TlBiS2 and TlSbS2 under hydrostatic pressure as well as uniaxial and biaxial strain. The phase transitions are identified by parity analysis and by calculating the surface states. Zero, one, and four Dirac cones are found for the (111) surfaces of both TlBiS2 and TlSbS2 when the pressure grows, which confirms trivial-nontrivial-trivial phase transitions. The Dirac cones at the (M) over bar points are anisotropic with large out-of-plane component. TlBiS2 shows normal, topological, and topological crystalline insulator phases under hydrostatic pressure, thus being the first compound to exhibit a phase transition from a topological to a topological crystalline insulator.

  18. Emergence of topological and topological crystalline phases in TlBiS2 and TlSbS2

    KAUST Repository

    Zhang, Qingyun; Cheng, Yingchun; Schwingenschlö gl, Udo

    2015-01-01

    Using first-principles calculations, we investigate the band structure evolution and topological phase transitions in TlBiS2 and TlSbS2 under hydrostatic pressure as well as uniaxial and biaxial strain. The phase transitions are identified by parity analysis and by calculating the surface states. Zero, one, and four Dirac cones are found for the (111) surfaces of both TlBiS2 and TlSbS2 when the pressure grows, which confirms trivial-nontrivial-trivial phase transitions. The Dirac cones at the (M) over bar points are anisotropic with large out-of-plane component. TlBiS2 shows normal, topological, and topological crystalline insulator phases under hydrostatic pressure, thus being the first compound to exhibit a phase transition from a topological to a topological crystalline insulator.

  19. Tl-201 per rectum scintigraphy in chronic liver disease: assessment of Tl-201 uptake indices

    International Nuclear Information System (INIS)

    Moon, Won Jin; Choi, Yun Young; Cho, Suk Shin; Lee, Min Ho

    1999-01-01

    Heart to liver ratio on Tl-201 per rectal scintigraphy (shunt index) is known to be useful in the assessment of portal systemic shunt. We assessed Tl-201 uptake pattern and early liver/heart uptake rate of Tl-201 and correlated with shunt index in patients with chronic active hepatitis (CAH) and liver cirrhosis (LC). Fifty eight patients with biopsy-proven chronic liver disease (35 with CAH, 23 with LC) underwent Tl-201 per rectum scintigraphy after instillation of 18.5 MBq of Tl-201 into the upper rectum. We evaluated hepatic uptake (type 1: homogeneous, 2: inhomogeneous segmental, 3: inhomogeneous nonsegmental) and extrahepatic uptake of spleen, heart and kidney (grade 0: no uptake, 1: less than liver, 2: equal to liver, 3: greater than liver). We measured the early liver/heart uptake rate (the slope of the liver to heart uptake ratio for 10 mim) and shunt index (heart to liver uptake ratio). Tl-201 uptake pattern and early liver/heart uptake rate of Tl-201 was correlated with the pathologic diagnosis and shunt index. Hepatic uptake patterns of type 1 and 2 were dominant in CAH (CAH: 27/35, LC: 8/23), and type 3 in LC (CAH: 8/35, LC: 15/23)(p<0.005). The grades of extrahepatic uptake were higher in LC than in CAH (spleen: p<0.001, other soft tissue: p<0.005). The early liver/heart uptake rate of CAH (0.110±0.111) was significantly higher than that of LC (0.014±0.090)(p<0.001). The sensitivity and specificity of the early liver/heart uptake rate were 77.7% and 67.7% in differentiating LC from CAH. There was negative correlation between early liver/heart uptake rate and shunt index (r=-0.3347, p<0.01). Hepatic and extrahepatic uptake pattern and early liver/heart uptake rate on Tl-201 per rectum scintigraphy are useful in the assessment of portal systemic shunt in patients with chronic liver disease

  20. Insight on a novel layered semiconductors: CuTlS and CuTlSe

    Energy Technology Data Exchange (ETDEWEB)

    Aliev, Ziya S., E-mail: ziyasaliev@gmail.com [Institute of Catalysis and Inorganic Chemistry, ANAS, H.Javid ave. 113, AZ1143 Baku (Azerbaijan); Institute of Physics, ANAS, H.Javid ave. 131, AZ1143 Baku (Azerbaijan); Donostia International Physics Center (DIPC), 20080 San Sebastian (Spain); Zúñiga, Fco. Javier [Departamento de Física de la Materia Condensada, Facultad de Ciencia y Tecnología, Universidad del País Vasco, Apdo. 644, 48080 Bilbao (Spain); Koroteev, Yury M. [Institute of Strength Physics and Materials Science, Russian Academy of Sciences, Siberian Branch, 634055 Tomsk (Russian Federation); Tomsk State University, Tomsk, 634050 (Russian Federation); Breczewski, Tomasz [Departamento de Física de la Materia Condensada, Facultad de Ciencia y Tecnología, Universidad del País Vasco, Apdo. 644, 48080 Bilbao (Spain); Babanly, Nizamaddin B. [Institute of Catalysis and Inorganic Chemistry, ANAS, H.Javid ave. 113, AZ1143 Baku (Azerbaijan); Amiraslanov, Imamaddin R. [Institute of Physics, ANAS, H.Javid ave. 131, AZ1143 Baku (Azerbaijan); Politano, Antonio [Department of Physics, University of Calabria, 87036 Rende (CS) (Italy); Madariaga, Gotzon [Departamento de Física de la Materia Condensada, Facultad de Ciencia y Tecnología, Universidad del País Vasco, Apdo. 644, 48080 Bilbao (Spain); Babanly, Mahammad B. [Institute of Catalysis and Inorganic Chemistry, ANAS, H.Javid ave. 113, AZ1143 Baku (Azerbaijan); and others

    2016-10-15

    Single crystals of the ternary copper compounds CuTlS and CuTlSe have been successfully grown from stoichiometric melt by using vertical Bridgman-Stockbarger method. The crystal structure of the both compounds has been determined by powder and single crystal X-Ray diffraction. They crystallize in the PbFCl structure type with two formula units in the tetragonal system, space group P4/nmm, a=3.922(2); c=8.123(6); Z=2 and a=4.087(6); c=8.195(19) Å; Z=2, respectively. The band structure of the reported compounds has been analyzed by means of full-potential linearized augmented plane-wave (FLAPW) method based on the density functional theory (DFT). Both compounds have similar band structures and are narrow-gap semiconductors with indirect band gap. The resistivity measurements agree with a semiconductor behavior although anomalies are observed at low temperature. - Graphical abstract: The crystal structures of CuTl and CuTlSe are isostructural with the PbFCl-type and the superconductor LiFeAs-type tetragonal structure. The band structure calculations confirmed that they are narrow-gap semiconductors with indirect band gaps of 0.326 and 0.083 eV. The resistivity measurements, although confirming the semiconducting behavior of both compounds exhibit unusual anomalies at low temperatures. - Highlights: • Single crystals of CuTlS and CuTlSe have been successfully grown by Bridgman-Stockbarger method. • The crystal structure of the both compounds has been determined by single crystal XRD. • The band structure of the both compounds has been analyzed based on the density functional theory (DFT). • The resistivity measurements have been carried out from room temperature down to 10 K.

  1. TL Dating Technique Based on a Trap Model and its Application as a Geochronometer for Granitic Quartz

    International Nuclear Information System (INIS)

    Han, Y.; Li, H.; Tso, Y.W.

    1999-01-01

    A trap model is introduced to describe the behaviours of both thermally sensitive and radiation sensitive TL traps. The former are relatively shallow traps. The latter are deep traps, in which population increases with exposure to alpha dose. Thermal decay of both types of traps at ambient temperature is dependent on the trap lifetimes. A trap's population can be measured as TL sensitivity to a laboratory test dose. The trap model has been supported by observations of age dependent TL signals from granitic quartz samples with different crystallisation ages. The trap lifetimes are from 1.98 x 10 9 to 5.36 x 10 15 years estimated using the isothermal decay experiment with the assumption of first order kinetics. Dating techniques are proposed based on the trap model. For old granites (>400 Ma), ages can be obtained by measuring the total exposed alpha dose using the additive alpha dose method, whereas for young granites (<400 Ma), ages can also be obtained by interpolating the TL sensitivity to a curve of TL sensitivities for known ages. (author)

  2. First approval procedure of the TL dosimetric service of the NPP in Slovenia

    International Nuclear Information System (INIS)

    Janzekovic, H.; Krizman, M.; Pucelj, B.; Stuhec, M.; Zdesar, U.

    2001-01-01

    The individual dosimetry of exposed workers in a NPP is one of the essential parts which demonstrates the radiation protection standards achieved in a facility. According to the current legislation the Ministry of Health of the Republic of Slovenia has the authority to grant approvals to personal dosimetric services which perform the dosimetric monitoring of workers in Slovenia. Due to the fact that the detailed approval procedure is not given in national regulations, the Ministry of Health in 2000 established a group of experts with the task to prepare technical and organising requirements for such approval. Based on international documents [1,2,3] the Approval procedure for the thermoluminescence dosimetric (TL) services was created. Following this procedure the assessment of the TL dosimetric service in the NPP was performed. The problems related to the technical and organising requirements with the emphasise on the QA/QC criteria of the TL dosimetric service will be discussed.(author)

  3. Prediction of half-metallic properties in TlCrS{sub 2} and TlCrSe{sub 2} based on density functional theory

    Energy Technology Data Exchange (ETDEWEB)

    Hashimzade, F.M.; Huseinova, D.A. [Institute of Physics, National Academy of Sciences of Azerbaijan, AZ 1143 Baku (Azerbaijan); Jahangirli, Z.A. [Institute of Physics, National Academy of Sciences of Azerbaijan, AZ 1143 Baku (Azerbaijan); Institute of Radiation Problems, National Academy of Sciences of Azerbaijan, AZ 1143 Baku (Azerbaijan); Mehdiyev, B.H., E-mail: bachschi@yahoo.de [Institute of Physics, National Academy of Sciences of Azerbaijan, AZ 1143 Baku (Azerbaijan)

    2017-08-01

    Highlights: • Half-metallic properties of TlCrS2, TlCrSe2 and hypothetical TlCrSSe have been investigated by first-principles all-electron full-potential linearized augmented plane wave plus local orbital (FP-LAPW+lo) method based on density functional theory (DFT). • Total magnetic moment keeps its integer value on a relatively wide range of changes in volume (−10% ÷ 10%) for TlCrS2 and TlCrSSe, while total magnetic moment TlCrSe2 decreases with increasing volume, approaching to integer value 3 μB. • The states at the Fermi level in the case of spin-up channel consist of a hybridization of p-states of the atom S(Se) with d-states of Cr. - Abstract: Half-metallic properties of TlCrS{sub 2}, TlCrSe{sub 2} and hypothetical TlCrSSe have been investigated by first-principles all-electron full-potential linearized augmented plane wave plus local orbital (FP-LAPW+lo) method based on density functional theory (DFT). The results of calculations show that TlCrS{sub 2} and TlCrSSe are half-metals with energy gap (E{sub g}) ∼0.12 eV for spin-down channel. Strong hybridization of p-state of chalchogen and d-state of Cr leads to bonding and antibonding states and subsequently to the appearance of a gap in spin-down channel of TlCrS{sub 2} and TlCrSSe. In the case of TlCrSe{sub 2}, there is a partial hybridization and p-state is partially present in the DOS at Fermi level making this compound nearly half-metallic. The present calculations revealed that total magnetic moment keeps its integer value on a relatively wide range of changes in volume (−10% ÷ 10%) for TlCrS{sub 2} and TlCrSSe, while total magnetic moment of TlCrSe{sub 2} decreases with increasing volume approaching to integer value 3 μB.

  4. A Comparison between HPGe and NaI(Tl) detectors performance for gamma-spectrometry of low level measurement

    International Nuclear Information System (INIS)

    Poursiamy, N. H.; Tajikahmadi, H.; Mirshojaei, S. F.

    2005-01-01

    According to progressive usage of nuclear technology, it's important to prevent the contamination of the environment by man-made radioisotopes and exposures of human being. Radioisotopes can enter the human body by inhalation and ingestion which are the most important ways to internal exposures. Measurement of radiation level in foodstuff is one of the most important parameters in environmental safety which is performed according to constitution and standard tests in most countries such as Iran. Gamma spectrometry is carried out by NaI(Tl) and HPGe detector systems for foodstuffs. In this research operation of HPGe and NaI(Tl) detectors in gamma spectrometry with a standard radioactive source are investigated and compared. Also the result of NaI superiority in foodstuff radiation measurement given

  5. Stability of Tl-Ba-Ca-Cu-O Superconducting Thin Films

    Energy Technology Data Exchange (ETDEWEB)

    Siegal, M.P.; Overmyer, D.L.; Venturini, E.L.; Padilla, R.R.; Provencio, P.N.

    1999-08-23

    We report the stability of TlBa{sub 2}CaCu{sub 2}O{sub 7} (Tl-1212) and Tl{sub 2}Ba{sub 2}CaCu{sub 2}O{sub 8} (T1-2212) thin films and by inference, the stability of TlBa{sub 2}Ca{sub 2}Cu{sub 3}O{sub 9} (Tl-1223) and Tl{sub 2}Ba{sub 2}Ca{sub 2}Cu{sub 3}O{sub 10} (Tl-2223) thin films, under a variety of conditions. In general, we observe that the stability behavior of the single Tl-O layer materials (Tl-1212 and Tl-1223)are similar and the double Tl-O layer materials (Tl-2212 and Tl-2223) are similar. All films are stable with repeated thermal cycling to cryogenic temperatures. Films are also stable in acetone and methanol. Moisture degrades film quality rapidly, especially in the form of vapor. Tl-1212 is more sensitive to vapor than Tl-2212. These materials are stable to high temperatures in either N{sub 2}, similar to vacuum for the cuprates, and O{sub 2} ambients. While total degradation of properties (superconducting and structural) occur at the same temperatures for all phases, 600 C in N{sub 2} and 700 C in O{sub 2}, the onset of degradation occurs at somewhat lower temperatures for Tl-1212 than for Tl-2212 films. In all cases, sample degradation is associated with Tl depletion from the films.

  6. From nGy to MGy - new TL dosimetry of complex radiation at high-energy accelerators and thermonuclear fusion facilities

    International Nuclear Information System (INIS)

    Obryk, B.; Bilski, P.; Budzanowski, M.; Olko, P.

    2011-01-01

    One of the well known advantages of thermoluminescence (TL) detectors made of lithium fluoride doped with magnesium, copper and phosphorus (LiF:Mg,Cu,P) is their very high sensitivity to ionizing radiation. LiF:Mg,Cu,P detectors enable measurements of radiation doses from tens of nano grays up to a few kilo grays, when the total saturation of the signal of the so-called main dosimetric peak (at about 220 C. degrees) occurs. In 2006 for the first time we observed unprecedented high-temperature emission of LiF detectors heated to temperatures up to 600 C. degrees, after exposures to radiation doses ranging from 1 kGy to 1 MGy. For quantification of the glow curve shape changes of LiF:Mg,Cu,P detectors in this range of doses and determination of the absorbed dose, the high temperature coefficient (UHTR) was defined. This newly established dosimetric method was tested in a range of radiation qualities, such as gamma radiation, electron and proton beams, thermal neutron fields and in high-energy mixed fields around the SPS and PS accelerators at CERN. A number of dosimetric sets with LiF:Mg,Cu,P detectors are currently installed around the LHC at CERN. The new method for ultra-high dose range monitoring with a single LiF:Mg,Cu,P detector, which is capable of covering at least twelve orders of magnitude of doses, can be used for dosimetry at high energy accelerators and has great potential for accident dosimetry in particular. (authors)

  7. NaI(Tl) electron energy resolution

    CERN Document Server

    Mengesha, W

    2002-01-01

    NaI(Tl) electron energy resolution eta sub e was measured using the Modified Compton Coincidence Technique (MCCT). The MCCT allowed detection of nearly monoenergetic internal electrons resulting from the scattering of incident 662 keV gamma rays within a primary NaI(Tl) detector. Scattered gamma rays were detected using a secondary HPGe detector in a coincidence mode. Measurements were carried out for electron energies ranging from 16 to 438 keV, by varying the scattering angle. Measured HPGe coincidence spectra were deconvolved to determine the scattered energy spectra from the NaI(Tl) detector. Subsequently, the NaI(Tl) electron energy spectra were determined by subtracting the energy of scattered spectra from the incident source energy (662 keV). Using chi-squared minimization, iterative deconvolution of the internal electron energy spectra from the measured NaI(Tl) spectra was then used to determine eta sub e at the electron energy of interest. eta sub e values determined using this technique represent va...

  8. Estudìo por medio de potenciales evocados de la respuesta cortical en sujetos sometidos a dos estresores de laboratorio y su relación con la respuesta cardiovascular, endocrina y psicologica.

    OpenAIRE

    Pellicer Porcar, Olga

    2008-01-01

    RESUMEN En esta tesis se presenta un estudio mediante potenciales evocados visuales de la respuesta cortical a dos estresores de laboratorio, uno de afrontamiento activo y otro pasivo, asimismo se ha estudiado la correlación de la actividad cortical con la respuesta cardiovascular de los sujetos y con variables psicológicas relevantes en la modulación de dicha respuesta, como la percepción de estrés y de dolor provocada por los estresores. Hemos determinado también la respuesta de cortisol...

  9. A New Approach for the Determination of Dose Rate and Radioactivity for Detected Gamma Nuclides Using an Environmental Radiation Monitor Based on an NaI(Tl) Detector.

    Science.gov (United States)

    Ji, Young-Yong; Kim, Chang-Jong; Lim, Kyo-Sun; Lee, Wanno; Chang, Hyon-Sock; Chung, Kun Ho

    2017-10-01

    To expand the application of dose rate spectroscopy to the environment, the method using an environmental radiation monitor (ERM) based on a 3' × 3' NaI(Tl) detector was used to perform real-time monitoring of the dose rate and radioactivity for detected gamma nuclides in the ground around an ERM. Full-energy absorption peaks in the energy spectrum for dose rate were first identified to calculate the individual dose rates of Bi, Ac, Tl, and K distributed in the ground through interference correction because of the finite energy resolution of the NaI(Tl) detector used in an ERM. The radioactivity of the four natural radionuclides was then calculated from the in situ calibration factor-that is, the dose rate per unit curie-of the used ERM for the geometry of the ground in infinite half-space, which was theoretically estimated by Monte Carlo simulation. By an intercomparison using a portable HPGe and samples taken from the ground around an ERM, this method to calculate the dose rate and radioactivity of four nuclides using an ERM was experimentally verified and finally applied to remotely monitor them in real-time in the area in which the ERM had been installed.

  10. Tiempo de Respuestas y Experiencia de Usuario Estudio Experimental

    Directory of Open Access Journals (Sweden)

    Delvis Echeverria

    2016-12-01

    Full Text Available La investigación está fundamentada por un estudio experimental, enfocado en la evaluación del comportamiento de los usuarios finales interactuando con tiempos de respuestas en aplicaciones reales. Se tomará como base el aporte de los autores Doherty y Thadani, investigadores de IBM relacionado con los tiempos de respuestas, y las investigaciones de Jacob Nielsen. Se llevarán a cabo un test con usuarios finales, y se expondrán optimizaciones a través de del uso de herramientas que contribuirán a mejorar los tiempos de respuestas de las aplicaciones web. Todo esto engloba una primera instancia de un proyecto que se está llevando a cabo en la empresa GeneXus Consulting, pretendiéndose lograr un punto de encuentro entre el rendimiento de las aplicaciones y la experiencia de usuario.

  11. Investigation of physical detection markers in irradiated foods under different radiation sources and post-irradiation storage conditions

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Joong Ho; Kim, Gui Ran; Ahn, Jae Jun; Kim, Dong Gil; Jin, Qiong Wen; Park, Ju Hwan; Lee, Ji Hyun [Kyungpook National University, Daegu (Korea, Republic of)

    2010-04-15

    In PSL analysis, all unirradiated samples showed less than 700 (negative) photon counts (PCs). At 5 kGy, spice samples showed PCs in range of 700-5,000 (intermediate), while grains, legumes, root-crops, and seasonings samples showed PCs over 5,000 (positive). This PSL based-detection of radiation treatment was possible even after 24 months of storage. In TL analysis, TL glow curve was characteristically different between unirradiated and irradiated samples. Glow curves were observed in temperature ranges of 150-250 .deg. C for irradiated and over 300 .deg. C for unirradiated samples. TL ratio (TL{sub 1}/TL{sub 2}) provided valuable additional confirmations as unirradiated sample showed values less than 0.1, while irradiated sample showed more than 0.1. However, with storage time, TL intensity and TL ratio decreased but discrimination was still possible even after storage of 24 months. Samples stored at room temperature with exposure to direct or indirect light enhanced the mentioned decrease of TL intensity and TL ratio as compared to low temperature storage in dark room. In ESR analysis, legumes and spices showed radiation-induced cellulose radicals, while seasonings showed multi-component signals of radiation-induced crystalline sugar radical. These radiation-induced radicals could be potential markers for the detection of radiation treatments in subjected samples. The decreasing trend was also found for radiation-specific ESR signals of cellulose and crystalline sugar radicals during storage. However, radiation-induced radicals in legumes, powdered pepper and seasonings were detectable even after 6 months of storage

  12. Copper interactions in TlCu7S4 and TlCu7Se4

    International Nuclear Information System (INIS)

    Noren, L.; Delaplane, R.G.; Berger, R.

    1999-01-01

    Complete text of publication follows. The copper chalcogenides ACu 7 S 4 (A=NH 4 + , Tl + , Rb + ) are quasi-one-dimensional metals at ambient and higher temperatures which is due to the high mobility of copper in these structures. TlCu 7 S 4 and TlCu 7 Se 4 are isostructural compounds, space group I4/m, which can be described on the basis of a TlX 8 cube with two different Cu sites, Cu(1) and Cu(2). Cu(2)-Cu(2) zigzag chains run along the c axis with only 3/4 occupation of the Cu(2) sites. However, these two compounds differ in behaviour on cooling. The sulphide shows a polymorphic first-order transition to the CsAg 7 S 4 type (P4/n) owing to ordering of the vacancies in the Cu(2)-Cu(2) chains. In order to study the nature of the Cu(2) order/disorder in the two title compounds, a series of neutron diffraction measurements (both Bragg and diffuse scattering) were made at several temperatures from 40 to 713 K on the instrument SLAD at Studsvik. The structure at each temperature was modelled using RMC techniques. The resulting configuration show that as the temperature increases, there is a marked increase in the mobility of the Cu atoms in the Cu(2)-Cu(2) chains for TlCu 7 S 4 but not for TlCu 7 Se 4 . This is due to the initial difference in the Cu(2)-Cu(2) distances, only 2.2A for the thiocuprate, but 2.7A in the selenocuprate which explains the relative ease for Cu(2) ordering in the latter case. (author)

  13. [Tl(III)(dota)](-): An Extraordinarily Robust Macrocyclic Complex.

    Science.gov (United States)

    Fodor, Tamás; Bányai, István; Bényei, Attila; Platas-Iglesias, Carlos; Purgel, Mihály; Horváth, Gábor L; Zékány, László; Tircsó, Gyula; Tóth, Imre

    2015-06-01

    The X-ray structure of {C(NH2)3}[Tl(dota)]·H2O shows that the Tl(3+) ion is deeply buried in the macrocyclic cavity of the dota(4-) ligand (1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetate) with average Tl-N and Tl-O distances of 2.464 and 2.365 Å, respectively. The metal ion is directly coordinated to the eight donor atoms of the ligand, which results in a twisted square antiprismatic (TSAP') coordination around Tl(3+). A multinuclear (1)H, (13)C, and (205)Tl NMR study combined with DFT calculations confirmed the TSAP' structure of the complex in aqueous solution, which exists as the Λ(λλλλ)/Δ(δδδδ) enantiomeric pair. (205)Tl NMR spectroscopy allowed the protonation constant associated with the protonation of the complex according to [Tl(dota)](-) + H(+) ⇆ [Tl(Hdota)] to be determined, which turned out to be pK(H)Tl(dota) = 1.4 ± 0.1. [Tl(dota)](-) does not react with Br(-), even when using an excess of the anion, but it forms a weak mixed complex with cyanide, [Tl(dota)](-) + CN(-) ⇆ [Tl(dota)(CN)](2-), with an equilibrium constant of Kmix = 6.0 ± 0.8. The dissociation of the [Tl(dota)](-) complex was determined by UV-vis spectrophotometry under acidic conditions using a large excess of Br(-), and it was found to follow proton-assisted kinetics and to take place very slowly (∼10 days), even in 1 M HClO4, with the estimated half-life of the process being in the 10(9) h range at neutral pH. The solution dynamics of [Tl(dota)](-) were investigated using (13)C NMR spectroscopy and DFT calculations. The (13)C NMR spectra recorded at low temperature (272 K) point to C4 symmetry of the complex in solution, which averages to C4v as the temperature increases. This dynamic behavior was attributed to the Λ(λλλλ) ↔ Δ(δδδδ) enantiomerization process, which involves both the inversion of the macrocyclic unit and the rotation of the pendant arms. According to our calculations, the arm-rotation process limits the Λ(λλλλ) ↔

  14. Modification of radiation-induced murine thymic lymphoma incidence by curcumin

    International Nuclear Information System (INIS)

    Dange, P.S.; Yadav, H.D.; Kumar, Vimalesh; Bhilwade, H.N.; Pandey, B.N.; Sarma, H.D.

    2017-01-01

    Curcumin is a known antioxidant, preventing radiation damage including carcinogenesis. However, concentration and feeding schedule of curcumin in modification of radiation induced thymic lymphoma incidence in vivo model has not been studied. We report here modification of incidence of γ-radiation-induced thymic lymphoma in mice fed with different doses of curcumin (0.05 to 1 %) in diet. Results: Female Swiss mice (6-8 weeks) fed with normal diet and exposed to 3 Gy whole body "6"0Co γ-irradiation (WBI) showed 85 % incidence of thymic lymphoma (TL) at 120 days post-irradiation. A concentration of 1 % curcumin was found the most effective in TL incidence prevention than other fed concentrations. The TL incidence was remarkably reduced when curcumin was fed to the mice before than after the radiation exposure. These results suggest modification of TL incidence by curcumin in irradiated mice involving DNA damage and apoptotic death mechanisms

  15. Ultrashort-period lateral composition modulation in TlInGaAsN/TlInP structures

    International Nuclear Information System (INIS)

    Ishimaru, Manabu; Tanaka, Yuusuke; Hasegawa, Shigehiko; Asahi, Hajime; Sato, Kazuhisa; Konno, Toyohiko J.

    2009-01-01

    We prepared TlInGaAsN/TlInP quantum well structures using gas source molecular-beam epitaxy and characterized them by means of transmission electron microscopy and scanning transmission electron microscopy. It was found that naturally formed vertical quantum wells, so-called lateral composition modulation (LCM), with a periodicity of ∼1 nm are formed in TlInGaAsN layers. We discuss their formation process using a simple kinetic Ising model for layer-by-layer growth, and point out that the formation of ultrashort-period LCM is a universal phenomenon in most of epitaxially grown III-V semiconductor alloys.

  16. Individual TL detector characteristics in automated processing of personnel dosemeters: correction factors as extension to identity codes of dosemeter cards

    International Nuclear Information System (INIS)

    Toivonen, Matti.

    1979-07-01

    One, two and three-component dosemeter cards and their associated processing equipment were developed for personnel monitoring. A novel feature of the TLD system is that the individual sensitivity correction factors of TL detectors for β/γ radiation dosimetry and special timing factors for the readout of neutron detectors are stored on dosemeter cards as an extension of the identity codes. These data are utilized in the automatic TL reading process with the aim of cancelling out the influence of the individual detector characteristics on the measuring results. Stimulation of TL is done with hot nitrogen without removing the detectors from their cards and without any metal contact. Changes in detector characteristics are thus improbable. The reading process can be adjusted in a variety of ways. For example, each detector in the same card can be processed with optimal heating and the specific 250 deg C glow peak of neutron radiation can be roughly separated from the main LiF glow peaks. (author)

  17. Multi-band Monopole Antennas Loaded with Metamaterial TL

    Science.gov (United States)

    Song, Zhi-jie; Liang, Jian-gang

    2015-05-01

    A novel metamaterial transmission line (TL) by loading complementary single Archimedean spiral resonator pair (CSASRP) is investigated and used to design a set of multi-frequency monopole antennas. The particularity is that the CSASRP which features dual-shunt branches in the equivalent circuit model is directly etched in the signal strip. By smartly controlling the element parameters, three antennas are designed and one of them covering UMTS and Bluetooth bands is fabricated and measured. The antenna exhibits impedance matching better than -10 dB and normal monopolar radiation patterns at working bands of 1.9-2.22 and 2.38-2.5 GHz. Moreover, the loaded element also contributes to the radiation, which is the major advantage of this prescription over previous lumped-element loadings. The proposed antenna is also more compact over previous designs.

  18. Characterization of cartilaginous tumors with 201Tl scintigraphy

    International Nuclear Information System (INIS)

    Higuchi, Takahiro; Taki, Junichi; Sumiya, Hisashi; Kinuya, Seigo; Nakajima, Kenichi; Tonami, Norihisa

    2005-01-01

    Histological diagnosis and grading of cartilaginous tumors are closely correlated with patient prognosis; consequently, they are essential elements. We attempted to clarify the characteristics of 201 Tl uptake in various histological types of cartilaginous tumors and to assess its clinical value. Twenty-two cases with histologically proven cartilaginous tumors (3 enchondromas, 15 conventional chondrosarcomas (grade I=9, II=5, III=1), 3 mesenchymal chondrosarcomas, and 1 de-differentiated chondrosarcoma) were examined retrospectively. Planar 201 Tl images were recorded 15 mm following intravenous injection of 201 Tl (111 MBq). 201 Tl uptake in the tumor was evaluated visually employing a five-grade scoring system: 0=no appreciable uptake, 1=faint uptake above the background level, 2=moderate uptake, 3=intense uptake but lower than heart uptake and 4=uptake higher than heart uptake. 201 Tl uptake scores were 0 in 3 of 3 enchondromas, 9 of 9 grade I, and 4 of 5 grade II conventional chondrosarcomas. 201 Tl uptake scores were 1 among 1 of 5 grades II and a grade III conventional chondrosarcoma. Mesenchymal chondrosarcoma and de-differentiated chondrosarcoma displayed 201 Tl uptake scores of 2 or 3. Absence of elevated 201 Tl uptake in cartilaginous tumors was indicative of enchondroma or low-grade conventional chondrosarcoma. However, in instances in which 201 Tl uptake is obvious, high-grade chondrosarcoma or variant types should be considered. (author)

  19. Stark broadening parameters and transition probabilities of persistent lines of Tl II

    Science.gov (United States)

    de Andrés-García, I.; Colón, C.; Fernández-Martínez, F.

    2018-05-01

    The presence of singly ionized thallium in the stellar atmosphere of the chemically peculiar star χ Lupi was reported by Leckrone et al. in 1999 by analysis of its stellar spectrum obtained with the Goddard High Resolution Spectrograph (GHRS) on board the Hubble Space Telescope. Atomic data about the spectral line of 1307.50 Å and about the hyperfine components of the spectral lines of 1321.71 Å and 1908.64 Å were taken from different sources and used to analyse the isotopic abundance of thallium II in the star χ Lupi. From their results the authors concluded that the photosphere of the star presents an anomalous isotopic composition of Tl II. A study of the atomic parameters of Tl II and of the broadening by the Stark effect of its spectral lines (and therefore of the possible overlaps of these lines) can help to clarify the conclusions about the spectral abundance of Tl II in different stars. In this paper we present calculated values of the atomic transition probabilities and Stark broadening parameters for 49 spectral lines of Tl II obtained by using the Cowan code including core polarization effects and the Griem semiempirical approach. Theoretical values of radiative lifetimes for 11 levels (eight with experimental values in the bibliography) are calculated and compared with the experimental values in order to test the quality of our results. Theoretical trends of the Stark width and shift parameters versus the temperature for spectral lines of astrophysical interest are displayed. Trends of our calculated Stark width for the isoelectronic sequence Tl II-Pb III-Bi IV are also displayed.

  20. Thallous chalcogenide (Tl 6I 4Se) for radiation detection at X-ray and γ-ray energies

    Science.gov (United States)

    Liu, Zhifu; Peters, John A.; Wessels, Bruce W.; Johnsen, Simon; Kanatzidis, Mercouri G.

    2011-12-01

    The optical and charge transport properties of the thallous chalcogenide compound Tl6I4Se were characterized. The semiconductor crystals are grown by the modified Bridgman method. We have measured the refractive index, and absorption coefficient of the compound ranging from 300 to 1500 nm by analysis of the UV-vis-near IR transmission and reflection spectra. The band gap is 1.8 eV. For the evaluation of detector performance, the mobility-lifetime products for both the electron and hole carriers were measured. Tl6I4Se has mobility-lifetime products of 7.1×10-3 and 5.9×10-4 cm2/V for electron and hole carriers, respectively, which are comparable to those of Cd0.9Zn0.1Te. The γ-ray spectrum for a Tl6I4Se detector was measured. Its response to the 122 keV of 57Co source is comparable to that of Cd0.9Zn0.1Te.

  1. Phytotoxicity of thallium (Tl) in culture solution. Pt. 1. Effects of Tl(I) on the growth and heavy metal contents of pea and field bean plants

    Energy Technology Data Exchange (ETDEWEB)

    Poetsch, U; Austenfeld, F A

    1985-01-01

    The effects of TlNO/sub 3/ and Tl(I)EDTA on growth and heavy metal contents of pea plants and field bean plants were compared in hydroponic culture experiments. In the presence of TlNO/sub 3/, the essential heavy metals were available to the plants in their ionic forms. When Tl(I)EDTA was present the essential heavy metals were available as chelated complexes. With increasing concentration of TlNO/sub 3/ dry matter production of pea plants was lowered and the Tl content of each organ was increased. The highest Tl content was found within the stems. The increased Tl contents were accompanied by depressed Mn, Zn, and Cu contents of the roots and depressed Mn contents of the stems, but increased Fe contents of the stems. Substitution of TlNO/sub 3/ by Tl(I)EDTA resulted in a stronger growth inhibition of the pea plants, and higher Tl contents of each organ. The highest Tl content was found within the stems. Tl(I)EDTA depressed Mn in the roots, but increased Fe and Mn in the stems, and Fe, Zn and Cu in the leaves. The increases may due to concentration by growth inhibition. The growth of the field bean was not effected by TlNO/sub 3/ nor by Tl(I)EDTA. The field bean contained most of the Tl within the roots and translocated only relatively small amounts to the shoots. This pattern was independent of the Tl compound. Increasing concentrations of TlNO/sub 3/ resulted in depressed Mn and Zn contents of the roots, and Mn contents of the stems. Chelation of Tl(I) resulted in a decrease of the Tl content of each organ. Tl(I)EDTA depressed only the Mn content of the roots.

  2. OSL and TL of Resistors of Mobile Phones for Retrospective Accident Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J. I.; Kim, J. L.; Pradhan, A. S.; Chang, I.; Kim, B. H. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-05-15

    Optically stimulated luminescence (OSL) and thermoluminescence (TL) of ubiquitous materials continue to draw wider attention for individual dosimetry in nuclear and radiation accidents. Use of ubiquitous objects for radiation dosimetry is preferred because the affected persons in such unexpected events are usually not covered by personal dosimetry services and do not carry personal dosimeters. Often accident sites do not have area monitoring system in place. As the main concern of the dosimetry is health effects, a quick distinction of level of exposures of the affected persons for the required medical care becomes important in all accidents involving radiation. Both in large scale nuclear accidents such Fukushima, Chernobyl or Hiroshima and Nagasaki where large population around the accident site get exposed to radiation (evacuation is based on doses) and in smaller but panicky events, such as misuse of radiological exposure device (RED), radiological dispersive device (RDD: 'Dirty Bomb'), improvised nuclear device (IND) and deliberate dispersal of radioactive contaminants, a need for an ubiquitous personal dosimeter is well recognized. As biological dosimetry systems are yet to become viable for measurements of doses with required accuracy and speed, use of physical dosimeters is often explored. Among the various types of physical dosimetry systems, use of TL and OSL by processing common material such as bricks or tiles and measuring the doses cumulated for long periods of time has already become an accepted tool for large scale nuclear accidents such as Hiroshima and Nagasaki or Chernobyl involving higher doses. In the other potential cases of unexpected situations where the doses encountered could be much lower (even to escape the range of remotely installed area monitors), the need to measure even the low doses in shortest possible time becomes important. It is often realized that in such situations, the main problem could become the panic at the

  3. OSL and TL of Resistors of Mobile Phones for Retrospective Accident Dosimetry

    International Nuclear Information System (INIS)

    Lee, J. I.; Kim, J. L.; Pradhan, A. S.; Chang, I.; Kim, B. H.

    2012-01-01

    Optically stimulated luminescence (OSL) and thermoluminescence (TL) of ubiquitous materials continue to draw wider attention for individual dosimetry in nuclear and radiation accidents. Use of ubiquitous objects for radiation dosimetry is preferred because the affected persons in such unexpected events are usually not covered by personal dosimetry services and do not carry personal dosimeters. Often accident sites do not have area monitoring system in place. As the main concern of the dosimetry is health effects, a quick distinction of level of exposures of the affected persons for the required medical care becomes important in all accidents involving radiation. Both in large scale nuclear accidents such Fukushima, Chernobyl or Hiroshima and Nagasaki where large population around the accident site get exposed to radiation (evacuation is based on doses) and in smaller but panicky events, such as misuse of radiological exposure device (RED), radiological dispersive device (RDD: 'Dirty Bomb'), improvised nuclear device (IND) and deliberate dispersal of radioactive contaminants, a need for an ubiquitous personal dosimeter is well recognized. As biological dosimetry systems are yet to become viable for measurements of doses with required accuracy and speed, use of physical dosimeters is often explored. Among the various types of physical dosimetry systems, use of TL and OSL by processing common material such as bricks or tiles and measuring the doses cumulated for long periods of time has already become an accepted tool for large scale nuclear accidents such as Hiroshima and Nagasaki or Chernobyl involving higher doses. In the other potential cases of unexpected situations where the doses encountered could be much lower (even to escape the range of remotely installed area monitors), the need to measure even the low doses in shortest possible time becomes important. It is often realized that in such situations, the main problem could become the panic at the work place

  4. La respuesta inmune antiviral

    Directory of Open Access Journals (Sweden)

    Rainel Sánchez de la Rosa

    1998-02-01

    Full Text Available Se expone que los virus son parásitos intracelulares obligados, puesto que no tienen metabolismo propio; esto obliga al sistema inmune a poner en marcha sus mecanismos más especializados para reconocer y eliminar, tanto a los virus libres, como a las células infectadas. Se señala que las células presentadoras de antígenos, los linfocitos B y los T unidos al complejo mayor de histocompatibilidad, forman parte de la organización de la respuesta inmune antiviral; la inducción de esta respuesta con proteínas, péptidos y ADN desnudo, son alternativas actuales tanto en la prevención como en el tratamiento de las infecciones viralesIt is explained that viruses are compulsory intracellular parasites, since they don't have their own metabolism, which makes the immune system to start its mest specialized mechanisms to recognize and eliminate the free viruses and the infected cells. It is stated that the cells presenting antigens, and the B and T lymphocytes together with the major histocompatibility complex, are part of the organization of the immune antiviral response. The induction of this response with proteins, peptides and naked DNA are the present alternatives for the prevention and treatment of viral infections

  5. Principles of Good Practice in SoTL

    Science.gov (United States)

    Felten, Peter

    2013-01-01

    For the Scholarship of Teaching and Learning (SoTL) to be understood as significant intellectual work in the academy, SoTL practitioners need to identify shared principles of good practice. While honoring the diversity of SoTL in its many forms across the globe, such principles can serve as a heuristic for assessing work in our field. These…

  6. New colour centres in KCl:(Tl+ + Ca2+) and KCl:(Tl+ + Sr2+) crystals

    International Nuclear Information System (INIS)

    Ioan, A.; Topa, V.; Giurgea, M.

    1978-01-01

    Electrolytic colouring under unusual conditions (low temperature and high voltage) gives rise to the appearance of three new absorption bands peaking at 3.2, 2.5, and 1.7 eV and at 2.8, 2.1, and 1.5 eV in KCl:(Tl + + Ca 2+ ) and in KCl:(Tl + + Sr 2+ ) single crystals, respectively. The modifications of the absorption spectra of the coloured crystals induced by the application of a reversed electric field at the colouring temperature or by heat treatment are investigated. It is likely that the colour centre responsible for the new absorption bands is an aggregate centre which, besides an Tl - -complex, contains also at least an Ca(Sr) ion, a trapped electron, and an anionic vacancy. (author)

  7. Improved spectrometric characteristics of thallium bromide nuclear radiation detectors

    CERN Document Server

    Hitomi, K; Shoji, T; Suehiro, T; Hiratate, Y

    1999-01-01

    Thallium bromide (TlBr) is a compound semiconductor with a high atomic number and wide band gap. In this study, nuclear radiation detectors have been fabricated from the TlBr crystals. The TlBr crystals were grown by the horizontal travelling molten zone (TMZ) method using the materials purified by many pass zone refining. The crystals were characterized by measuring the resistivity, the mobility-lifetime (mu tau) product and the energy required to create an electron-hole pair (the epsilon value). Improved energy resolution has been obtained by the TlBr radiation detectors. At room temperature the full-width at half-maximum (FWHM) for the 59.5, 122 and 662 keV gamma-ray photo peak obtained from the detectors were 3.3, 8.8 and 29.5 keV, respectively. By comparing the saturated peak position of the TlBr detector with that of the CdTe detector, the epsilon value has been estimated to be about 5.85 eV for the TlBr crystal.

  8. Deformation effects in electronic spectra of the layered semiconductors TlGaS sub 2 , TlGaSe sub 2 and TlInS sub 2

    CERN Document Server

    Allakhverdiev, K R; Suleymanov, R A; Gasanov, N Z

    2003-01-01

    The deformation effects in electronic spectra of the ternary layered semiconductors TlGaS sub 2 , TlGaSe sub 2 and TlInS sub 2 are considered. It is shown that the influence of hydrostatic pressure, thermal expansion and variation of composition in solid solutions on the band gap of the crystals investigated can be described in the framework of one common model of deformation potentials. This model appears to be close to that of layered semiconductors of the A sub 3 B sub 6 group, attesting to the fact that the main principles of formation of band structure in these two groups of layered crystals are the same.

  9. OSL and TL dosimeter characterization of boron doped CVD diamond films

    Science.gov (United States)

    Gonçalves, J. A. N.; Sandonato, G. M.; Meléndrez, R.; Chernov, V.; Pedroza-Montero, M.; De la Rosa, E.; Rodríguez, R. A.; Salas, P.; Barboza-Flores, M.

    2005-04-01

    Natural diamond is an exceptional prospect for clinical radiation dosimetry due to its tissue-equivalence properties and being chemically inert. The use of diamond in radiation dosimetry has been halted by the high market price; although recently the capability of growing high quality CVD diamond has renewed the interest in using diamond films as radiation dosimeters. In the present work we have characterized the dosimetric properties of diamond films synthesized by the HFCVD method. The thermoluminescence and the optically stimulated luminescence of beta exposed diamond sample containing a B/C 4000 ppm doping presents excellent properties suitable for dosimetric applications with β-ray doses up to 3.0 kGy. The observed OSL and TL performance is reasonable appropriate to justify further investigation of diamond films as dosimeters for ionizing radiation, specially in the radiotherapy field where very well localized and in vivo and real time radiation dose applications are essential.

  10. Effect of particle size in the TL response of natural quartz sensitized by high dose of gamma radiation and heat-treatments

    Directory of Open Access Journals (Sweden)

    Álvaro Barbosa de Carvalho Jr

    2010-06-01

    Full Text Available This work investigates the effect of particle size in the thermoluminescence (TL response of a quartz crystal that was initially crushed and classified into ten size fractions between 38 μm and 5 mm. Aliquots of each size fraction were sensitized with a dose of 25 kGy of γ rays and heat-treatments at 400 °C. TL glow curves of sensitized and non-sensitized samples were recorded as a function of different test-doses of γ rays. For the non-sensitized samples, the TL peak near 325 °C increases with the decrease in particle size. In the case of sensitized samples, a strong TL peak near 300 °C increases with the increase in particle size up to mean grain size equal to 304 μm. Above 304 μm, an abrupt reduction in the TL intensity is noticed for the sensitized peak. These effects are discussed in relation to the specific surface area of quartz particles and the intensity of the electron paramagnetic resonance signal of the E'1 center induced by the sensitization process.

  11. In-house quality audit and benefits of some quality control procedures in the quality assurance of TL dosimetry system at NRPB

    International Nuclear Information System (INIS)

    Dutt, J.C.

    1993-01-01

    A number of Quality Control (QC) procedures have been introduced into the running and operation of the NRPB personal monitoring services. Those described here apply to the whole-body TL dosimetry system. These QC procedures comprise Quality Assurance (QA) of incoming raw materials and equipment, reader stabilisation, daily, routine and periodic QA checks on all phases of the service. In-house quality audit, periodic internal and external 'blind QA checks' on the dosimetry system as a whole have assured the continuing high quality and reliability of the NRPB TL dosimetry service for assessing body and skin doses of radiation workers from external photon and beta radiations. (author)

  12. $\\alpha$-decay study of $^{182,184}$Tl

    CERN Document Server

    Van Beveren, C; Barzakh, A E; Cocolios, T E; de Groote, R P; Fedorov, D; Fedosseev, V N; Ferrer, R; Ghys, L; Huyse, M; Köster, U; Lane, J; Liberati, V; Lynch, K M; Marsh, B A; Molkanov, P L; Procter, T J; Rapisarda, E; Sandhu, K; Seliverstov, M D; Van Duppen, P; Venhart, M; Veselský, M

    2016-01-01

    α -decay spectroscopy of 182,184 Tl has been performed at the CERN isotope separator on-line ( ISOLDE ) facility. New fi ne-structure α decays have been observed for both isotopes. α -decay branching ratios of 0.089 ( 19 ) %, 0.047 ( 6 ) % and 1.22 ( 30 ) % have been deduced for the ( 10 − ) , ( 7 + ) and ( 2 − ) states respectively in 184 Tl and a lower limit of 0.49% for the α -decay branching ratio of 182 Tl. A new half-life of 9.5 ( 2 ) s for the ( 2 − ) state in 184 Tl and 1.9 ( 1 ) s for the low-spin state in 182 Tl has been deduced. Using α – γ coincidence analysis, multiple γ rays were observed de-exciting levels in 178,18 0 Au fed by 182,184 Tl α decays. The γ transitions connecting these low-lying states in 178,18 0 Au are essential to sort the data and possibly identify bands from in- beam studies in these isotopes. Owing to the complex fi ne-structure α decays and limited knowledge about the structure of the daughter nuclei, only partial level schemes could be constructed for bot...

  13. Phytotoxicity of thallium (Tl) in culture solution. Pt. 2. Effects of Tl(III) on the growth and heavy metal contents of pea and field bean plants

    Energy Technology Data Exchange (ETDEWEB)

    Pieper, B; Austenfeld, F A

    1985-01-01

    The effects of Tl(NO/sub 3/)/sub 3/ and Tl(III)EDTA on growth and heavy metal contents of pea plants and field bean plants were compared in hydroponic culture experiments. In the presence of Tl(NO/sub 3/)/sub 3/, the essential heavy metals were available to the plants in their ionic forms. When Tl(III)EDTA was present the essential heavy metals were available as chelated complexes. Dry matter production of the pea plants was inhibited to a greater extent by Tl(III)EDTA than by Tl(NO/sub 3/)/sub 3/. The distribution of Tl within the plant was unaffected by the accompanying anion, however an increase of the Tl content of the stems and the leaves was observed in the presence of Tl(III)EDTA. The micronutrients exhibited different interactions with Tl(III). In the presence of increasing concentrations of Tl(NO/sub 3/)/sub 3/ the Mn content of each organ and the Zn content of the roots were lowered, but the Zn content of the stems was increased. Increasing concentrations of Tl(III)EDTA resulted only in a decrease of the Mn content of the roots, but in an increase of the contents of Fe and Mn within the stems, and Fe, Mn, Zn, and Cu within the leaves. The increases may be due to concentration by growth inhibition. In contrast to pea plants, growth of field bean plants was inhibited only by Tl(NO/sub 3/)/sub 3/. The field bean plants retained most of the Tl within the roots independent of the Tl compound in the solution. Chelation of Tl(III) resulted in higher Tl contents of both the roots and the stems, but equal or reduced Tl contents of the leaves. Whereas increasing concentrations of Tl(NO/sub 3/)/sub 3/ reduced the Mn content of each organ as well as the Zn content of the roots and the leaves, Tl(III)EDTA only reduced the Mn content of the roots.

  14. Neutron radiative capture methods for surface elemental analysis

    Science.gov (United States)

    Trombka, J.I.; Senftle, F.; Schmadebeck, R.

    1970-01-01

    Both an accelerator and a 252Cf neutron source have been used to induce characteristic gamma radiation from extended soil samples. To demonstrate the method, measurements of the neutron-induced radiative capture and activation gamma rays have been made with both Ge(Li) and NaI(Tl) detectors, Because of the possible application to space flight geochemical analysis, it is believed that NaI(Tl) detectors must be used. Analytical procedures have been developed to obtain both qualitative and semiquantitative results from an interpretation of the measured NaI(Tl) pulse-height spectrum. Experiment results and the analytic procedure are presented. ?? 1970.

  15. PFOA y PFOS - PREGUNTAS Y RESPUESTAS

    Science.gov (United States)

    Preguntas y respuestas sobre la decisión de la EPA de publicar avisos de salud sobre el ácido perfluorooctanoico (PFOA) y el sulfonato de perfluorooctano (PFOS) para proporcionar información a los operadores de sistemas de agua potable y funcionarios estat

  16. Importance of controlling the Tl-oxide partial pressure throughout the processing of TlBa2CaCu2O7 thin films

    International Nuclear Information System (INIS)

    Siegal, M.P.; Venturini, E.L.; Newcomer, P.P.; Overmyer, D.L.; Dominguez, F.; Dunn, R.

    1995-01-01

    TlBa 2 CaCu 2 O 7 (Tl-1212) superconducting films 5000--6000 A thick have been grown on LaAlO 3 (100) substrates using oxide precursors in a closed two-zone thallination furnace. Tl-1212 films can be grown with transition temperatures ∼100 K, and critical current densities measured by magnetization of J cm (5 K)>10 7 A/cm 2 and J cm (77 K)>10 5 A/cm 2 . Processing conditions, substrate temperatures and Tl-oxide source temperatures are found which result in smooth, nearly phase-pure Tl-1212 films. Variations in the respective temperature ramps of the Tl-oxide zone and the substrate zone can greatly influence resulting film properties such as microstructure, morphology, superconducting transition temperature, and critical current density. copyright 1995 American Institute of Physics

  17. Tl response of LiF: Mg, Cu, P+Ptfe at X rays of 24, 42 and 100 KeV

    International Nuclear Information System (INIS)

    Gonzalez M, P.R.; Tovar M, V.M.; Azorin N, J.; Furetta, C.; Quiroz C, M.C.

    2005-01-01

    In this work the obtained results of the irradiation of thermoluminescent dosemeters (Tl) of LiF: Mg,Cu,P + Ptfe with X rays for the effective radiation energy of 24, 42 and 100 keV, in an interval of Kerma in air in the sinus of the air between 0.05 and 1.0 Gy are presented. The rate of Kerma in air was determined with an ionization chamber PTW-1152, gauged by the Laboratoire Central des Industries Electriques (LCIE). As reference commercial TLD-100 dosemeters was used. The results showed that the studied Tl dosemeters presented a lineal response in the interval of mentioned Kerma. On the other hand the estimated Kerma with the Tl dosemeter in the calibration curves for X rays, were similar to the one measured with the previously gauged ionization chamber. The Tl of LiF: Mg, Cu, P + Ptfe, developed in the ININ, are highly reliable for X-ray dosimetry. (Author)

  18. Electron Spin Resonance (ESR) and Thermoluminescence (TL) studies of stalagmitic floors of the Caune de de L'Arago at Tautavel (France)

    International Nuclear Information System (INIS)

    Poupeau, G.; Teles, M.M.; Rossi, A.; Zuleta, E.; Yokoyama, Y.

    1984-01-01

    The geological radiation dose to the stalagmites of various stratigraphic levels of the Caune de L'Arago at Tautavel has been measured by Thermoluminescence (TL) and Electron Spin Resonance (ESR). In all samples the TL natural spectrum a well developped 280 0 C peak and a subordinate 350 0 C peak, while the ESR line spectrum may present the h 1 , h 2 and h 3 radiative lines of Yokoyama et al.) or only h 2 . All TL peaks and ESR lines do increase with the laboratory applied radiation (β or γ) doses. The activated h 2 line is visibly unstable in laboratory conditions as well as apparently the h 3 line in one sample. Within the experimental precision, the geological doses determined from the 280C peak and h 3 line on one band and the 350 0 C peak and h 1 line (after thermal treatment of the later, see Yokoyama et al. on the other hand are identical. When the 280C natural peak is visibly affected by natural fading as shown by the plateau test, so is h 3 , and the geological doses of the 280 0 C-h 3 peaks are lowered by the same factor as compared to those of the 350 0 C-h 1 peaks. Annealing experiments show that the relationships between the TL and ESR peaks may be difficult to analyse in some samples due to the possible occurence of non radiative components in some ESR lines. Such components appear clearly at temperatures above approx. 180-200 0 C and might possibly be present below. This may have important implications for the selection of samples to be dated by ESR. (Author) [pt

  19. Preparation of 199Tl and its labelled compound

    International Nuclear Information System (INIS)

    Zhou Dehai; Guan Changtian; Kuang Anren

    1991-10-01

    Usually, 199 Ti is obtained by the nuclear reaction of 197 Au(α, 2n) 199 Tl. A gold target with 50±0.1 mm in diameter, 0.8 mm in thickness and 99.99% in purity was mounted in a cyclotron beam line. The target was bombarded by α particles with the energy of 25∼27 MeV and the beam current of 15∼20μA. The irradiated gold target was dissolved by aqua regia. Then the saturated aqueous solution of SO 2 was added. The 199 Tl(III)reduced to 199 Tl(I). The deposit of gold was removed. For separation of 199 Tl)I), about 5 mL of raw material solution obtained was transferred to 201 x 8 type anion exchange resin column which had been equilibrated with 4 mol/L HCl. The 199 Tl(I) and Au(III) were desorbed separately with the eluants (90% of aqueous diamide solution,, and 2 mol/L HCL∼5% thiourea) at the flow rate of 0.25 mL/min. After separation, the 10 mL concentrated nitric acid was added to the 199 Tl collected solution to destroy and remove the aqueous diamide solution, then 4 mol/L HCl was added and heated up to remove NO 3 - . The TlCl injection with pH = 5 was made up by using physiological saline. After filtering the 199 TlCl injection was sterilized at 137.3 kPa, 120 deg C about 30 min in an autoclave. The 199 TlCl injection was used in the animal pyrogen, a bacterial, safety, dispensation and myocardial imaging experiments. The good results have been obtained. Now it has undergone clinical experiments

  20. Two crystal structures of Ag sup + -and Tl sup + -exchanged zeolite X, Ag sub 2 sub 7 Tl sub 6 sub 5 -X and Ag sub 2 sub 3 Tl sub 6 sub 9 -X

    CERN Document Server

    Kim, S Y; Kim, Y

    2002-01-01

    Two crystal structures of dehydrated Ag sup + -and Tl sup + -exchanged zeolite X (Ag sub 2 sub 7 Tl sub 6 sub 5 -X and Ag sub 2 sub 3 Tl sub 6 sub 9 -X) have been determined by single-crystal X-ray diffraction techniques in the cubic space group Fd3 at 21(1) .deg. C (a = 24.758(4) A, a = 24.947(4) A, respectively). Their structures were refined to the final error indices R sub 1 = 0.055 and wR sub 2 = 0.057 with 375 reflections, and R sub 1 = 0.058 and wR sub 2 = 0.057 with 235 reflections, respectively, for which I> 3 sigma(I). In the structure of Ag sub 2 sub 7 Tl sub 6 sub 5 -X, 27 Ag sup + ions were found at two crystallographic sites: 15 Ag sup + ions at site I at the center of the hexagonal prism and the remaining 12 Ag sup + ions at site II' in the sodalite cavity. Sixty-five Tl sup + ions were located at three crystallographic sites: 20 Tl sup + ions at site II opposite single six-rings in the supercage, 18 Tl sup + ions at site I' in the sodalite cavity opposite the D6Rs, and the remaining 27 Tl sup ...

  1. SCRLH-TL Based Sequential Rotation Feed Network for Broadband Circularly Polarized Antenna Array

    Directory of Open Access Journals (Sweden)

    B. F. Zong

    2016-04-01

    Full Text Available In this paper, a broadband circularly polarized (CP microstrip antenna array using composite right/left-handed transmission line (SCRLH-TL based sequential rotation (SR feed network is presented. The characteristics of a SCRLH-TL are initially investigated. Then, a broadband and low insertion loss 45º phase shifter is designed using the SCRLH-TL and the phase shifter is employed in constructing a SR feed network for CP antenna array. To validate the design method of the SR feed network, a 2×2 antenna array comprising sequentially rotated coupled stacked CP antenna elements is designed, fabricated and measured. Both the simulated and measured results indicate that the performances of the antenna element are further enhanced when the SR network is used. The antenna array exhibits the VSWR less than 1.8 dB from 4 GHz to 7 GHz and the 3 dB axial ratio (AR from 4.4 GHz to 6.8 GHz. Also, high peak gain of 13.7 dBic is obtained. Besides, the normalized radiation patterns at the operating frequencies are symmetrical and the side lobe levels are low at φ=0º and φ=90º.

  2. Radiation damage studies of mineral apatite, using fission tracks and thermoluminescence techniques

    International Nuclear Information System (INIS)

    Al-Khalifa, I.J.M.

    1988-01-01

    In a uranium (/thorium)-rich mineral sample which has not suffered a recent geological high-temperature excursion, the fossil fission track density (FFTD) will give a good indication of its natural radiation damage, provided that its U/Th ratio is known. From our studies of FFTD and thermoluminescence (TL) properties of several samples of apatite from different locations, and containing varying degrees of natural-radiation damage, an anti-correlation is observed between FFTD and TL sensitivity. It is also found that an anti-correlation exists between TL sensitivity and the amount of damage produced artificially by bombarding apatite crystals with different fluences of ∼30 MeV α-particles from a cyclotron. These results indicate that the presence of radiation damage in this mineral (viz., fluorapatite) can severely affect its TL sensitivity (i.e. TL output per unit test dose). The effect of crystal composition on the thermoluminescence and fission track annealing properties of mineral apatite is also reported. We have found that fission track annealing sensitivity and TL sensitivity are both significantly lower in samples of chlorapatite than in samples consisting predominantly of fluorapatite. (author)

  3. Investigation of the thermal stability of 210 deg. C TL peak of quartz and dating the components of terrazzo from the monastery church of Tegernsee

    International Nuclear Information System (INIS)

    Goeksu, H.Y.; Schwenk, P.; Semiochkina, N.

    2001-01-01

    The lifetime of the thermoluminescence (TL) peak of quartz observed at 210 deg. C using 5 deg. C/s heating rate is assessed using well-dated thermally isolated bricks from a monastery and exposed bricks from warmer climatic zones by comparing the absorbed dose obtained using the 210 deg. C TL peak with those obtained from 310 deg. C TL peak. The lifetimes of the 210 deg. C TL peak calculated for samples collected from thermally isolated excavations and exposed buildings are found to be clustered around 8000-10000 and 600-800 years, respectively. The results proved that 210 deg. C TL peak could be used for dating of samples younger than 1000 years without thermal correction if the samples are thermally isolated from their environment. TL ages are obtained using quartz, polyminerals from brick pieces as well as flint splinters, and other quartz inclusions extracted from the mortar of the terrazzo floor of the monastery church. The measured TL ages and the consistency of the results are discussed. The fine grains in the mortar, which contained calcite/aragonite, could not be dated using thermoluminescence due to presence of a very strong non-radiation induced TL glow

  4. Application of TL dosimetry in epidemiological studies in HBRAs

    International Nuclear Information System (INIS)

    Chougaonkar, M.P.

    2006-01-01

    Luminescence as a phenomenon has been extensively used in radiation dosimetry, using thermoluminescence. The nuclear industry all over the world over uses TL dosimetry in radiation protection since they have to ensure that the radiation workers and workers involved in industrial applications of radiation sources are not exposed beyond limits set by international monitoring bodies. They have also to ensure that the nuclear applications do not give rise to elevated radiation levels in the environs. In addition, epidemiologists and radiobiologists world over have been working over the past few decades, to study health effects of chronic radiation exposures in populations living in the elevated natural radiation environment. This paper discusses the importance of dosimetric studies, in the normal as well as high background radiation areas (HBRAs), due to the radiation effects on the humans. The application of thermoluminescent dosimeters (TLDs) in population dosimetry with the end point of epidemiological studies is then discussed. The paper outlines the construction of TLDs, methodology of deployment and retrieval and analysis to arrive the dose. To obtain total dose, dosimetric techniques suitable for external gamma radiation, inhalation dose due to radon, thoron and their progenies and radiological analysis of the food items is required. The techniques arriving at the effective dose are outlined. Basics of epidemiological analysis, particularly using case-control methodology and its advantages/ disadvantages are also discussed. Using the previous work by the author, the paper also reviews various analyses that can be carried out the dosimetric data. (author)

  5. Syntheses, crystal structures, and characterization of two new Tl{sup +}-Cu{sup 2+}-Te{sup 6+} oxides: Tl{sub 4}CuTeO{sub 6} and Tl{sub 6}CuTe{sub 2}O{sub 10}

    Energy Technology Data Exchange (ETDEWEB)

    Yeon, Jeongho; Kim, Sang-Hwan [Department of Chemistry, University of Houston, 136 Fleming Building, Houston, TX 77204-5003 (United States); Green, Mark A. [Department of Materials Science and Engineering, University of Maryland, College Park, MD, 20742-2115 and NIST Center for Neutron Research, National Institute of Standard and Technology, 100 Bureau Drive, Gaithersburg, MD 20899-6103 (United States); Bhatti, Kanwal Preet; Leighton, C. [Department of Chemical Engineering and Materials Science, University of Minnesota, Minneapolis, MN 55455-0132 (United States); Shiv Halasyamani, P., E-mail: psh@uh.edu [Department of Chemistry, University of Houston, 136 Fleming Building, Houston, TX 77204-5003 (United States)

    2012-12-15

    Crystals and polycrystalline powders of two new oxide materials, Tl{sub 4}CuTeO{sub 6} and Tl{sub 6}CuTe{sub 2}O{sub 10}, have been synthesized by hydrothermal and solid-state methods. The materials were structurally characterized by single-crystal X-ray diffraction. Tl{sub 4}CuTeO{sub 6} and Tl{sub 6}CuTe{sub 2}O{sub 10} exhibit one dimensional anionic slabs of [CuTeO{sub 6}]{sup 4-} and [CuTe{sub 2}O{sub 10}]{sup 6-}, respectively. Common to both slabs is the occurrence of Cu{sup 2+}O{sub 4} distorted squares and Te{sup 6+}O{sub 6} octahedra. The slabs are separated by Tl{sup +} cations. For Tl{sub 4}CuTeO{sub 6}, magnetic measurements indicate a maximum at {approx}8 K in the temperature dependence of the susceptibility. Low temperature neutron diffraction data confirm no long-range magnetic ordering occurs and the susceptibility was adequately accounted for by fits to a Heisenberg alternating chain model. For Tl{sub 6}CuTe{sub 2}O{sub 10} on the other hand, magnetic measurements revealed paramagnetism with no evidence of long-range magnetic ordering. Infrared, UV-vis spectra, thermogravimetric, and differential thermal analyses are also reported. Crystal data: Tl{sub 4}CuTeO{sub 6}, Triclinic, space group P-1 (No. 2), a=5.8629(8) A, b=8.7848(11) A, c=9.2572(12) A, {alpha}=66.0460(10), {beta}=74.2010(10), {gamma}=79.254(2), V=417.70(9) A{sup 3}, and Z=2; Tl{sub 6}CuTe{sub 2}O{sub 10}, orthorhombic, space group Pnma (No. 62), a=10.8628(6) A, b=11.4962(7) A, c=10.7238(6) A, V=1339.20(13) A{sup 3}, and Z=4. - Graphical Abstract: Two new oxide materials, Tl{sub 4}CuTeO{sub 6} and Tl{sub 6}CuTe{sub 2}O{sub 10}, have been synthesized and characterized. The materials exhibit one dimensional crystal structures consisting of CuO{sub 4} and TeO{sub 6} polyhedra. Highlights: Black-Right-Pointing-Pointer Two New Tl-Te-Cu-oxides have been synthesized and structurally characterized. Black-Right-Pointing-Pointer For Tl{sub 4}CuTeO{sub 6}, magnetic measurements indicate a

  6. Radiation dosimetry using nano-BaSO{sub 4}:Eu

    Energy Technology Data Exchange (ETDEWEB)

    Pandey, A.; Sharma R, K. [University of Delhi, Department of Physics, Sri Venkateswara College, Benito Juarez Road, Dhaula Kuan, 110021 New Delhi (India); Bahl, S.; Kumar, P. [Medical Physics Unit, IRCH, AIIMS, 110029 New Delhi (India); Pal L, S., E-mail: apandey@svc.ac.in [Inter-University Accelerator Centre, Aruna Asaf Ali Marg, 110067 New Delhi (India)

    2015-10-15

    Nanocrystalline barium sulfate doped with europium (BaSO{sub 4}:Eu) was successfully prepared by the chemical co-precipitation technique and its thermoluminescence (Tl) dosimetry characteristics were studied for gamma radiation. Initially the dopant (Eu) concentration was varied, starting from 0.05 mol % to up to 1.00 mol %, and it was found that the nano phosphor BaSO{sub 4}:Eu with the dopant concentration of 0.2 mol % had the highest sensitivity within the given lot. The nano phosphor was also optimized for its annealing temperature in order to obtain the best results and was thereafter tested for its reusability and fading features. Further the nano phosphor was compared with the commercially available standard Tl dosimeter material LiF:Mg,Ti (popularly referred to as TLD-100) and it was found that the nano phosphor not only had a higher Tl sensitivity compared to the standard material over a wide range of doses but also had a Tl response which was linear even beyond the dose of 1 kGy. Linearity in Tl response to up to such high doses (∼1 kGy) is typical of nanocrystalline Tl phosphors. All the samples were irradiated by Co-60 source (having 1.25 MeV average energy) of gamma radiation. In order to test the energy independence of the nano phosphor (an important characteristic of an ideal Tl dosimeter) further studies are being carried out to examine the response of the nano phosphor to ionizing radiations of different energies. (Author)

  7. Through an understanding of thermoluminescence phenomena from Einstein radiation theory

    Energy Technology Data Exchange (ETDEWEB)

    Nieto H, B; Vazquez C, G A; Azorin, J [UAM-I, 09340 Mexico D.F. (Mexico)

    2005-07-01

    In this work we made an outline of Einstein's radiation theory and its connection with elementary TL theory. We did not pretend in this paper to discuss advanced TL theories in these terms. Our main goal was to explore the simplest relationships among radiation theory, such as, transition probabilities and mean time-lives with kinetic parameters of the Randall-Wilkins model. (Author)

  8. Through an understanding of thermoluminescence phenomena from Einstein radiation theory

    International Nuclear Information System (INIS)

    Nieto H, B.; Vazquez C, G.A.; Azorin, J.

    2005-01-01

    In this work we made an outline of Einstein's radiation theory and its connection with elementary TL theory. We did not pretend in this paper to discuss advanced TL theories in these terms. Our main goal was to explore the simplest relationships among radiation theory, such as, transition probabilities and mean time-lives with kinetic parameters of the Randall-Wilkins model. (Author)

  9. Exploring the thermoelectric and magnetic properties of uranium selenides: Tl2Ag2USe4 and Tl3Cu4USe6

    International Nuclear Information System (INIS)

    Azam, Sikander; Khan, Saleem Ayaz; Din, Haleem Ud; Khenata, Rabah; Goumri-Said, Souraya

    2016-01-01

    The electronic, magnetic and thermoelectric properties of Tl 2 Ag 2 USe 4 and Tl 3 Cu 4 USe 6 compounds were investigated using the full potential linear augmented plane wave (FP-LAPW) method based on the density functional theory (DFT). The exchange correlation was treated with the generalized gradient approximation plus optimized effective Hubbard parameter and spin–orbit coupling (GGA+U+SOC). The present uranium selenides show narrow direct energy band gap values of 0.7 and 0.875 eV for Tl 2 Ag 2 USe 4 and Tl 3 Cu 4 USe 6 respectively. For both selenides U-d/f states are responsible for electrical transport properties. Uranium atoms were the most contributors in the magnetic moment compared to other atoms and show ferromagnetic nature. The spin density isosurfaces show the polarization of neighboring atoms of Uranium, such as silver/copper and selenium. Thermoelectric calculations reveal that Tl 3 Cu 4 USe 6 is more suitable for thermoelectric device applications than Tl 2 Ag 2 USe 4 . - Highlights: • Electronic, magnetic and thermoelectric properties of uranium selenides are investigated with DFT. • They show a narrow direct energy band gap of 0.7 and 0.875 eV. • U-d/f states are responsible for electrical transport properties. • Tl 3 Cu 4 USe 6 is more suitable for thermoelectric device applications than Tl 2 Ag 2 USe 4 .

  10. Thermoluminescent phosphors for ultraviolet radiation dosimetry - a review

    International Nuclear Information System (INIS)

    Nagpal, J.S.

    2001-01-01

    Intrinsic TL response of CaSO 4 , CaF 2 , Al 2 O 3 (Si,Ti), Mg 2 SiO 4 : Tb and lamp phosphors to ultraviolet radiation is reviewed. Taking into consideration the characteristics such as afterglow at RT, rate/flux dependence, linearity of response, useful range, spectral dependence and effect of sequential/tandem UV exposures CaF 2 :Eu 2+ is an ideal TL dosemeter for UV radiation dosimetry. (author)

  11. Chemical bonding in Tl cuprates studied by x-ray photoemission

    International Nuclear Information System (INIS)

    Vasquez, R.P.; Siegal, M.P.; Overmyer, D.L.; Ren, Z.F.; Lao, J.Y.; Wang, J.H.

    1999-01-01

    Epitaxial thin films of the Tl cuprate superconductors Tl 2 Ba 2 CaCu 2 O 8 , Tl 2 Ba 2 Ca 2 Cu 3 O 10 , and Tl 0.78 Bi 0.22 Ba 0.4 Sr 1.6 Ca 2 Cu 3 O 9-δ are studied with x-ray photoemission spectroscopy. These data, together with previous measurements in this lab of Tl 2 Ba 2 CuO 6+δ and TlBa 2 CaCu 2 O 7-δ , comprise a comprehensive data set for a comparative study of Tl cuprates with a range of chemical and electronic properties. In the Cu 2p spectra, a larger energy separation between the satellite and main peaks (E s -E m ) and a lower intensity ratio (I s /I m ) are found to correlate with higher values of T c . Analysis of these spectra within a simple configuration interaction model suggests that higher values of T c are related to low values of the O 2p→Cu 3d charge transfer energy. In the O 1s region, a smaller bond length between Ba and Cu-O planar oxygen is found to correlate with a lower binding energy for the signal associated with Cu-O bonding, most likely resulting from the increased polarization screening by Ba 2+ ions. For samples near optimum doping, maximum T c is observed to occur when the Tl 4f 7/2 binding energy is near 117.9 eV, which is near the middle of the range of values observed for Tl cuprates. Higher Tl 4f 7/2 binding energies, corresponding to formal oxidation states nearer Tl 1+ , are also found to correlate with longer bond lengths between Ba and Tl-O planar oxygen, and with higher binding energies of the O 1s signal associated with Tl-O bonding. copyright 1999 The American Physical Society

  12. Activation energies from blue- and red-thermoluminescence (TL) of quartz grains and mean lives of trapped electrons related to natural red-TL

    International Nuclear Information System (INIS)

    Hashimoto, T.; Kojima, M.; Shirai, N.; Ichino, M.

    1993-01-01

    A three-dimensional representation of thermoluminescence (TL) spectra has been established by employing an image intensifier unit combined with a simple spectrophotometer and a microcomputer. By means of this TL spectrometric system, natural quartz grains could be distinguished as either blue-and/or red-TL ones. In these blue- and red-TL wavelength regions, activation energies from artificially irradiated quartz grains are evaluated using a repeated initial rise method. An apparent difference of activation energies in the two colorations was observed for dune sands presumably originating from different quartz sources. On the other hand, quartz grains extracted from a volcanic ash sediment showed completely similar activation energies in both TL color regions over all temperatures. Subsequently, the kinetic parameters were derived for the naturally occurring red-TL, possessing an apparent single peak around 340 o C, from volcanically originating quartz grains by fitting a theoretical equation to the glow curves, after evaluating activation energies. On the basis of the empirical kinetic parameters, the mean life of trapped electrons relating to a main 340 o C peak has been proved to be 1 million years, and a secondary weak peak around 280 o C in the natural red-TL glow curve has been confirmed. (author)

  13. Color centers in heavily irradiated CsI(Tl) crystals

    International Nuclear Information System (INIS)

    Yakovlev, V.; Meleshko, A.; Trefilova, L.

    2008-01-01

    The absorption and luminescence properties of CsI(Tl) crystals colored by irradiation are studied by the method of the time-resolved spectroscopy. The scheme of the electron transitions in CsI(Tl) crystal is suggested to explain the appearance of the color centers under exposure to the near-UV light. It is established that either of the two types activator color centers holds the charge carrier with opposite sign. The model of the hole Tl 2+ v c - activator color center is suggested. According to the model the positive charge of Tl 2+ ion is compensated by the negative charge of a close cation vacancy v c - . The color center emission reveals in the cathode-luminescence spectrum of the colored CsI(Tl) crystal. The high-dose irradiation of CsI(Tl) crystal results in the reduction of the decay time of the near-thallium self-trapped excitons (STE) emission. The decay kinetics of Tl 2+ v c - emission contains the time components typical for the decay kinetics of near-thallium STE emission. The reason of the observed effects is the energy transfer from the near-thallium STE excitons to the color centers via the inductive-resonant mechanism

  14. Ab initio calculations of the electron spectrum and density of states of TlFeS{sub 2} and TlFeSe{sub 2} crystals

    Energy Technology Data Exchange (ETDEWEB)

    Ismayilova, N. A., E-mail: ismayilova-narmin-84@mail.ru; Orudjev, H. S.; Jabarov, S. H. [Azerbaijan National Academy of Sciences, Institute of Physics (Azerbaijan)

    2017-04-15

    The results of ab initio calculations of the electron spectrum of TlFeS{sub 2} and TlFeSe{sub 2} crystals in the antiferromagnetic phase are reported. Calculations are carried out in the context of the density functional theory. The origin of the bands of s, p, and d electron states of Tl, Fe, S, and Se atoms is studied. It is established that, in the antiferromagnetic phase, the crystals possess semiconductor properties. The band gaps are found to be 0.05 and 0.34 eV for TlFeS{sub 2} and TlFeSe{sub 2} crystals, respectively.

  15. Ceramics baking temperature influence on the dosimetric parameters essential in TL dating

    International Nuclear Information System (INIS)

    Krumpschmid, K.R.

    1986-11-01

    Thermoluminescence in quartz is used for dating of ceramics. The main problem is the 'intercept', i.e. the deviation from linearity in the relationship thermoluminescence versus absorbed dose of natural radiation. This deviation is most probably dependent on the fabrication method of the ceramics. In the present work the hypothesis is tested that the most important parameter, in this respect, is the baking temperature. Four types of ceramic bricks were fabricated, with four burning cycles of end temperatures of 550 0 C, 650 0 C, 900 0 C and 1200 0 C respectively, then irradiated and finally underwent the TL-procedure. The results are discussed with regard of the maximum of glow curve, intensity, fading, sensitivity to beta radiation and to additional alpha radiation and the intercept. (qui)

  16. In vivo effects of radioactive properties of Tl-201 on human carbonic anhydrase activity

    Science.gov (United States)

    Sahin, Ali; Senturk, Murat

    2017-04-01

    Carbonic anhydrase (CA) is a family of metalloenzymes that requires Zn as a cofactor and catalyze the quick conversion of CO2 to HCO3- and H+. Inhibitors of the carbonic anhydrases (CAs) have medical usage of significant diseases such as glaucoma, epilepsy, gastroduodenal ulcers, acid-base disequilibria and neurological disorders. The most useful radioisotope, Tl-201, decays by electron capture, emitting Hg X-rays ( 70-80 keV), and photons of 135 and 167 keV in 10% total abundance. Therefore, it has good imaging characteristics without excessive patient radiation dose. It is the most popular isotope used for thallium 201 nuclear cardiac stress tests. In the present study, In vivo inhibitory effect of Tl-201 (Thallium-201) on human erythrocyte carbonic anhydrase (CA) activity were investigated.

  17. Retrospective dosimetry using EPR and TL techniques: a status report

    Energy Technology Data Exchange (ETDEWEB)

    Haskell, E.H.

    1996-12-31

    Methods of retrospective dosimetry, including luminescence and electron paramagnetic resonance spectroscopy (EPR), rely on measurement of accident dose absorbed by naturally occurring materials - ceramics in the case of both thermoluminescence (TL) and optically stimulated luminescence (OSL) and organic materials and bio- minerals in the case of EPR. Each of these methods relies on measurement of radiation defects resulting from accidental exposure. Since defects also result from natural sources of radiation over the lifetime of a sample, analysis is usually restricted to materials for which the natural dose may be determined and subtracted from the measured cumulative dose. Luminescence dating techniques rely heavily on an accurate assessment of cumulative dose from natural radiation sources, and dating research has provided us with the bulk of our knowledge in this area. Virtually all of the work on natural dose determination can be directly applied to retrospective techniques. With EPR techniques the cumulative dose from diagnostic x- rays is also of importance.

  18. Retrospective dosimetry using EPR and TL techniques: a status report

    International Nuclear Information System (INIS)

    Haskell, E.H.

    1996-01-01

    Methods of retrospective dosimetry, including luminescence and electron paramagnetic resonance spectroscopy (EPR), rely on measurement of accident dose absorbed by naturally occurring materials - ceramics in the case of both thermoluminescence (TL) and optically stimulated luminescence (OSL) and organic materials and bio- minerals in the case of EPR. Each of these methods relies on measurement of radiation defects resulting from accidental exposure. Since defects also result from natural sources of radiation over the lifetime of a sample, analysis is usually restricted to materials for which the natural dose may be determined and subtracted from the measured cumulative dose. Luminescence dating techniques rely heavily on an accurate assessment of cumulative dose from natural radiation sources, and dating research has provided us with the bulk of our knowledge in this area. Virtually all of the work on natural dose determination can be directly applied to retrospective techniques. With EPR techniques the cumulative dose from diagnostic x- rays is also of importance

  19. Dosimetric characteristics of LKB:Cu,P solid TL detector

    International Nuclear Information System (INIS)

    Hashim, S.; Alajerami, Y.S.M.; Ghoshal, S.K.; Saleh, M.A.; Saripan, M.I.; Kadir, A.B.A.; Bradley, D.A.; Alzimami, K.

    2014-01-01

    The dosimetric characteristics of newly developed borate glass dosimeter modified with lithium and potassium carbonate (LKB) and co-doped with CuO and NH 4 H 2 PO 4 are reported. Broad peaks in the absence of any sharp peak confirms the amorphous nature of the prepared glass. A simple glow curve of Cu doped sample is observed with a single prominent peak (T m ) at 220 °C. The TL intensity response shows an enhancement of ∼100 times due to the addition of CuO (0.1 mol%) to LKB compound. A further enhancement of the intensity by a factor of 3 from the addition of 0.25 mol% NH 4 H 2 PO 4 as a co-dopant impurity is attributed to the creation of extra electron traps with consequent increase in energy transfer of radiation recombination centers. The TL yield performance of LKB:Cu,P with Z eff ≈8.92 is approximately seventeen times less sensitive compared to LiF:Mg,Ti (TLD-100). The proposed dosimeter shows good linearity up to 10 3 Gy, minimal fading and photon energy independence. These attractive features offered by our dosimeter is expected to pave the way towards dosimetric applications. - Highlights: • The NH 4 H 2 PO 4 impurities are cross linked with the CuO defect. • The addition of NH 4 H 2 PO 4 as a co-dopant improved the TL intensity by a factor of 3. • The proposed dosimeter shows good linearity up to 10 3 Gy. • Minimal fading and photon energy independence were observed

  20. Standardization of 201Tl and 55Fe radionuclides in a 4 (PC)-NaI(Tl) coincidence system

    International Nuclear Information System (INIS)

    Pires, Carlos Augusto

    2008-01-01

    In the present work the procedure for the standardization of radionuclides using the 4π(PC)-NaI(Tl) coincidence system was developed. The radionuclides selected were 201 Tl, used in nuclear medicine, and 55 Fe primary standard source, used for x-ray spectrometers calibration. The 4π(PC)-NaI(Tl) is composed of a 4 proportional counter operated at 0.1MPa coupled to two NaI(Tl) crystals. The 201 Tl decays by electron capture process followed by a prompt gamma-ray. The disintegration rate was determined by extrapolation technique using two methods: electronic discrimination and external absorbers. The radioactive sources were prepared in a 20 μg cm -2 thick Collodion film. The conventional electronic system was used. The observed events were registered by the TAC method. The 55 Fe decays by electron capture process to the ground state of 55 Mn, emitting x rays with around 6 keV. The standardization was obtained by the tracing method. This technique was applied using two radionuclides, which decay by electron capture process followed by a prompt gamma-ray, namely 51 Cr and 54 Mn, as tracers. Measurements with 1 and 2 aluminum foils, each 150 g cm-2 thick were carried out. The activity was obtained by extrapolation for zero thickness Al foil. The uncertainties were treated by means of matrix covariance methodology and takes into account all correlations involved. (author)

  1. Through an understanding of thermoluminescence phenomena from Einstein radiation theory

    Energy Technology Data Exchange (ETDEWEB)

    Nieto H, B.; Vazquez C, G.A.; Azorin, J. [UAM-I, 09340 Mexico D.F. (Mexico)

    2005-07-01

    In this work we made an outline of Einstein's radiation theory and its connection with elementary TL theory. We did not pretend in this paper to discuss advanced TL theories in these terms. Our main goal was to explore the simplest relationships among radiation theory, such as, transition probabilities and mean time-lives with kinetic parameters of the Randall-Wilkins model. (Author)

  2. Electrochemically produced alumina as TL detector

    International Nuclear Information System (INIS)

    Osvay, M.

    1996-01-01

    The goal of this work was to compare the TL properties of various electrochemically produced alumina layers (E-AIO) in order to investigate the effect of the electrolyte and the Mg content on the alloys. It has been found that the TL sensitivity of oxidised layers is more influenced by the type of electrolyte, than by the composition of alloy. Hard oxide layer evolved in reduction electrolyte has rather different character compared to other alumina production investigated. The effect of reducing media seems to be very important during preparation of alumina layer. One of the advantages properties of E-AIO is, that it serve a promising method to increase the measuring range of TL method above 10 kGy as well. (author)

  3. Evaluation of the substitution of PMMA plates by PLA 3D printed in TL response of CaSO{sub 4}:Dy; Avaliacao da substituicao de placas de PMMA por PLA impresso 3D na resposta TL do CaSO{sub 4}:Dy

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Shirlane Barbosa de; Valeriano, Caio Cesar Santos; Campos, Leticia Lucente, E-mail: caio144fisicamedica@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2016-07-01

    The CaSO{sub 4}:Dy is a dosimetric material that is nationally produced, which presents high sensibility but a high energy dependence of its thermoluminescent (TL) response at the photoelectric effect region. This study aims to compare the TL response of the CaSO{sub 4}:Dy when irradiated, with different energies, at the presence of 3D printed plates of polylactic acid (PLA) and polymethylmethacrylate (PMMA). Results show that the PLA has a different attenuation of the radiation, when compared to PMMA, indicating that it should be taken into account the quality of the print used on PLA plates manufacture. (author)

  4. Papel de las células nkt invariantes en la respuesta inmune anti-viral

    OpenAIRE

    Román, Alejandro; Rugeles, María Teresa; Montoya, Carlos Julio

    2006-01-01

    Las células T asesinas naturales con receptor de células T invariante y restringidas por la molécula CD1d (iNKT) son un subgrupo de linfocitos con potente actividad inmunorreguladora; su respuesta casi inmediata y la capacidad de producir citoquinas tanto Th1 como Th2 son factores determinantes en el desarrollo de la respuesta inmune innata y adaptativa. El papel fisiológico de las células iNKT se ha documentado ampliamente en la respuesta anti-tumoral, el desarrollo de la tolerancia en los ó...

  5. Chemical Bonding in Tl Cuprates Studied by X-Ray Photoemission

    Energy Technology Data Exchange (ETDEWEB)

    Lao, J.Y.; Overmyer, D.L.; Ren, Z.F.; Siegal, M.P.; Vasquez, R.P.; Wang, J.H.

    1999-04-05

    Epitaxial thin films of the Tl cuprate superconductors Tl{sub 2}Ba{sub 2}CaCu{sub 2}O{sub 8}, Tl{sub 2}Ba{sub 2}Ca{sub 2}Cu{sub 3}O{sub 10}, and TL{sub 0.78}Bi{sub 0.22}Ba{sub 0.4}Sr{sub 1.6}Ca{sub 2}Cu{sub 3}O{sub 9{minus}{delta}} are studied with x-ray photoemission spectroscopy. These data, together with previous measurements in this lab of Tl{sub 2}Ba{sub 2}CuO{sub 6+{delta}} and TlBa{sub 2}CaCu{sub 2}O{sub 7{minus}{delta}}, comprise a comprehensive data set for a comparative study of Tl cuprates with a range of chemical and electronic properties. In the Cu 2p spectra, a larger energy separation between the satellite and main peaks (E{sub s}-E{sub m}) and a lower intensity ratio (I{sub s}/I{sub m}) are found to correlate with higher values of T{sub c}. Analysis of these spectra within a simple configuration interaction model suggests that higher values of T{sub c} are related to low values of the O 2p {r_arrow} Cu 3d charge transfer energy. In the O 1s region, a smaller bond length between Ba and Cu-O planar oxygen is found to correlate with a lower binding energy for the signal associated with Cu-O bonding, most likely resulting from the increased polarization screening by Ba{sup 2+} ions. For samples near optimum doping, maximum T{sub c} is observed to occur when the Tl 4f{sub 7/2} binding energy is near 117.9 eV, which is near the middle of the range of values observed for Tl cuprates. Higher Tl 4f{sub 7/2} binding energies, corresponding to formal oxidation states nearer Tl{sup 1+}, are also found to correlate with longer bond lengths between Ba and Tl-O planar oxygen, and with higher binding energies of the O 1s signal associated with Tl-O bonding.

  6. Chemical bonding in Tl cuprates studied by x-ray photoemission

    Energy Technology Data Exchange (ETDEWEB)

    Vasquez, R.P. [Center for Space Microelectronics Technology, Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California 91109-8099 (United States); Siegal, M.P.; Overmyer, D.L. [Sandia National Laboratories, Albuquerque, New Mexico 87185-1421 (United States); Ren, Z.F.; Lao, J.Y.; Wang, J.H. [Materials Synthesis Laboratory, Department of Chemistry, State University of New York, Buffalo, New York 14260-3000 (United States)

    1999-08-01

    Epitaxial thin films of the Tl cuprate superconductors Tl{sub 2}Ba{sub 2}CaCu{sub 2}O{sub 8}, Tl{sub 2}Ba{sub 2}Ca{sub 2}Cu{sub 3}O{sub 10}, and Tl{sub 0.78}Bi{sub 0.22}Ba{sub 0.4}Sr{sub 1.6}Ca{sub 2}Cu{sub 3}O{sub 9{minus}{delta}} are studied with x-ray photoemission spectroscopy. These data, together with previous measurements in this lab of Tl{sub 2}Ba{sub 2}CuO{sub 6+{delta}} and TlBa{sub 2}CaCu{sub 2}O{sub 7{minus}{delta}}, comprise a comprehensive data set for a comparative study of Tl cuprates with a range of chemical and electronic properties. In the Cu 2p spectra, a larger energy separation between the satellite and main peaks (E{sub s}{minus}E{sub m}) and a lower intensity ratio (I{sub s}/I{sub m}) are found to correlate with higher values of T{sub c}. Analysis of these spectra within a simple configuration interaction model suggests that higher values of T{sub c} are related to low values of the O&hthinsp;2p{r_arrow}Cu&hthinsp;3d charge transfer energy. In the O&hthinsp;1s region, a smaller bond length between Ba and Cu-O planar oxygen is found to correlate with a lower binding energy for the signal associated with Cu-O bonding, most likely resulting from the increased polarization screening by Ba{sup 2+} ions. For samples near optimum doping, maximum T{sub c} is observed to occur when the Tl 4f{sub 7/2} binding energy is near 117.9 eV, which is near the middle of the range of values observed for Tl cuprates. Higher Tl&hthinsp;4f{sub 7/2} binding energies, corresponding to formal oxidation states nearer Tl{sup 1+}, are also found to correlate with longer bond lengths between Ba and Tl-O planar oxygen, and with higher binding energies of the O&hthinsp;1s signal associated with Tl-O bonding. {copyright} {ital 1999} {ital The American Physical Society}

  7. Pulse shaper for scintillation detectors with NaI(Tl) or CsI(Tl) crystals

    International Nuclear Information System (INIS)

    Novisov, B.S.; Maksimenko, A.S.; Baryshev, A.V.; Zhukov, A.V.

    1978-01-01

    The basic circuit of a signal shaper for scintillation detectors with NaI(Tl) and CsI(Tl) crystals is described. To increase amplitude resolution, it is suggested to integrate not the whole charge at the photomultiplier output, but a part of the charge during the initial 100 ns of the current pulse; the remaining part of the current signal is compensated directly at the photomultiplier anode by means of an electric circuit. The principal elements of the spectrometric signal shaper include an input transistor amplifier, a compensation circuit, a key element, a shaper amplifier of time pulses, a shaper of signal duration for controlling the key element, and an output spectrometric amplifier. This device, being used, one can shape pulses at durations of 100 ns and more. The shaper restoration time does not exceed 50 ns. When the shaper operates with NaI(Tl) crystals and at counting rate of 10 6 pulse/s, the amplitude resolution with and without the compensation circuit is 17% and 21% respectively

  8. Alpha efficiency under TL and OSL - A subtraction technique using OSL and TL to detect artificial irradiation

    International Nuclear Information System (INIS)

    Zink, A.J.C.; Dabis, S.; Porto, E.; Castaing, J.

    2010-01-01

    With the development of thermoluminescence (TL) and optically stimulated luminescence (OSL) to determine the authenticity of old ceramics, forgers use artificial irradiation by gamma ray to age modern productions. Besides fraudulent action, objects can be exposed to various sources of X-rays (e.g. radiography, security control at airports). For all these reasons, the determination of artificial irradiation is an important topic for dating art objects. The main technique to identify artificial irradiations is the subtraction technique. It is based on the fact that alpha efficiency varies according to the luminescence technique (fine grain, coarse grains, predose, OSL). Having observed a rather significant difference of alpha efficiency for TL and OSL, we propose a new subtraction technique using OSL and TL of fine grains.

  9. Development of thin dosemeters of CaSO4: Dy for beta radiation detection

    International Nuclear Information System (INIS)

    Campos, L.L.

    1987-01-01

    Thin pellets of CaSO: Dy (0,20mm) were produced and tested in beta radiation fields. The Thermolumiscent (TL) characteristics studied were sensitivity, reproducibility, lower detection limit, linearity of TL response with absorved dose energy dependence. The results show the usefulness of this thin pellets in beta radiation detection. (Author) [pt

  10. Main Achievements 2003-2004 - Interdisciplinary Research - Radiation detection methods for health, earth and environmental sciences - Thermoluminescence (TL) detectors

    International Nuclear Information System (INIS)

    2005-01-01

    The IFJ has over 35 years of experience in the development, production and application of new types of thermoluminescence (TL) detectors, particularly LiF:Mg,Ti and LiF:Mg,Cu,P. Over 600,000 LiF detectors produced at the IFJ PAN are routinely applied in dosimetry services and hospitals in 30 countries. The current research in the field of thermoluminescence concentrates in space dosimetry and novel 2-dimensional detectors for medical applications. The space project (named Matroshka), organized by the European Space Agency, is one of the most ambitious dosimetry experiments in space. In February 2004 an anatomical model of the human body (a humanoid phantom), equipped with over 3500 dedicated thermoluminescent detectors (TLD), developed and produced at IFJ and tested at the Chiba heavy ion accelerator in Japan, was installed outside the International Space Station (ISS) to determine the cosmic radiation doses absorbed in human organs, which would be experienced by astronauts in open space. The phantom will remain in space for one year, after which the detectors will be returned to the IFJ for analysis

  11. Remote TL and OSL for asteroid and meteorite study

    International Nuclear Information System (INIS)

    Takaki, Shunji; Ikeya, Motoji; Yamanaka, Chihiro

    1997-01-01

    Thermoluminescence (TL) and optically stimulated luminescence (OSL) of the Allende meteorite have been studied using infrared CO 2 laser light as a heat source and He-Ne laser light to excite the material, respectively from a long distance. New techniques of remote TL (R-TL) and remote OSL (R-OSL) have been developed for future remote dating from a long distance in a planetary survey. The upper limits of the distance for R-TL and R-OSL were estimated using the laboratory TL signal of the meteorite peaking at 320 o C: about 400 photons s -1 for the R-TL and 60 photons s -1 for R-OSL at a distance of 1 km using a laser beam with the divergence of 0.1 mrad at powers of 100 and 1 W, respectively. An age limit of 10 5 or 10 6 years due to the signal saturation and the objects heterogeneity, as expected from previous studies, may make the asteroid survey difficult but would still help to investigate the surface activities of icy planets and satellites in outer planet worlds. (author)

  12. Studies on the tumor and organ affinity of /sup 201/Tl

    Energy Technology Data Exchange (ETDEWEB)

    Mori, H; Ando, I; Takeuchi, T [Kanazawa Univ. (Japan). School of Medicine; Ando, A; Hiraki, T

    1980-01-01

    In order to evaluate the tumor and organ affinity of /sup 201/Tl, using the Yoshida sarcoma bearing rats, the distribution of /sup 201/Tl/sup +/ in tissues and tumor was examined and compared to /sup 22/Na/sup +/, /sup 42/K/sup +/, /sup 86/Rb/sup +/, /sup 134/Cs/sup +/, and /sup 67/Ga-citrate. /sup 201/Tl/sup +/ showed almost same organ accumulation and kinetics as /sup 42/K/sup +/, /sup 86/Rb/sup +/, /sup 134/Cs, whereas /sup 201/Tl/sup +/ and /sup 22/Na/sup +/ had completely different organ distribution. These results suggest that organ affinity of /sup 201/Tl/sup +/ might be related to active transport, namely Na/sup +/-K/sup +/-ATPase pump mechanism as well as blood flow. However, it appeared to be taken into account the other factors such as different accumulation and clearance rate due to different substrates of organs. Kidney accumulation rate of /sup 201/Tl/sup +/ was much higher than /sup 42/K/sup +/, /sup 86/Rb/sup +/, /sup 134/Cs/sup +/ and about 10 times as /sup 42/K/sup +/. Macroautoradiograms of rat kidneys showed that /sup 201/Tl/sup +/ exhibited an initial high accumulation in the cortex and appeared in the outer cortex, as the cortex cleared of radioactivity. /sup 201/Tl might be interchangeable with K/sup +/ in the tubular system, reabsorbed with more affinity and cleared more slowly than K/sup +/. The tumor accumulation /sup 201/Tl/sup +/ might be related to Na/sup +/-K/sup +/-ATPase pump mechanism as well as other organs. However, in terms of tumor accumulation and concentration ratio to other organs, /sup 201/Tl/sup +/ was inferior to /sup 67/Ga-citrate, although the tumor to blood ratio was identical to that of /sup 67/Ga-citrate. Since /sup 201/Tl/sup + + +/ showed almost same distribution as /sup 201/Tl/sup +/, /sup 201/Tl/sup + + +/ might change into /sup 201/Tl/sup +/ in vivo.

  13. Gamma-ray detectors for intelligent, hand-held radiation monitors

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1983-01-01

    Small radiation detectors based on HgI 2 , bismuth germanate (BGO), plastic, or NaI(Tl) detector materials were evaluated for use in small, lighweight radiation monitors. The two denser materials, HgI 2 and BGO, had poor resolution at low-energy and thus performed less well than NaI(Tl) in detecting low-energy gamma rays from bare, enriched uranium. The plastic scintillator, a Compton recoil detector, also performed less well at low gamma-ray energy. Two small NaI(Tl) detectors were suitable for detecting bare uranium and sheilded plutonium. One became part of a new lightweight hand-held monitor and the other found uses as a pole-mounted detector for monitoring hard-to-reach locations

  14. Seguridad ciudadana y respuesta penal

    Directory of Open Access Journals (Sweden)

    Beatriz Scapusio Minvielle

    2015-10-01

    Full Text Available El concepto de seguridad ciudadana será empleado en esta comunicación en su sentido restringido, vinculado al sentimiento de confianza de la población de no verse expuesta a hechos de violencia física, tengan origen éstos en actos individuales o sociales.  (...Contenido: Diferentes expresiones de la seguridad ciudadana. La respuesta penal. Evaluación global del problema. El desafío dogmático. Conclusiones

  15. TL Dosimetry on the Tandetron Ion Accelerator area of the ININ; Dosimetria TL en el area del Acelerador de iones Tandetron del ININ

    Energy Technology Data Exchange (ETDEWEB)

    Valdovinos A, M.A.; Gonzalez M, P.R. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2000-07-01

    For the fulfilment of the operation tests of the Positive Ions type Tandetron 4120 MC, 2 MV, it was obtained the permission consented by the National Commission of Nuclear safety and safeguards (CNSNS). During the stage of tests were arranged Tl dosemeters in the Tandetron Accelerator area, as well as toward to the beam exit. In this work, it was presented the results obtained of the measurement of radiation levels, as much in the area as in the beam exit. This Accelerator is useful in different fields of science such as: biology, radiochemistry, materials, solid state physics, archaeology and environmental sciences between others. (Author)

  16. Thermoluminescence studies of the thermal and radiation histories of chondritic meteorites

    International Nuclear Information System (INIS)

    Melcher, C.L.

    1980-01-01

    The thermoluminescence properties of chondritic meteorites are investigated to understand the ways in which the stored TL reflects the thermal and radiation histories of these objects. Differences in TL levels measured in recent falls are attributed to small differences in orbital temperatures. In addition, a correlation between TL level and terrestrial age is observed in meteorites of known terrestrial age. The thermoluminescence in chondrites is produced primarily by ionization from galactic cosmic rays with a much smaller contribution from the decay of natural radionuclides (U, Th, K, Rb). The production of most of the TL occurs after the break up of the large parent bodies into meter-size objects which are thus exposed to the ionizing effects of the cosmic rays. Measurements indicate that the low temperature TL represents a dynamic equilibrium between build up from ionizing radiation and thermal draining. The high temperature TL is near saturation. The terrestrial ages currently of greatest interest are those of the recently discovered meteorites in Antarctica. TL measurements were made on 11 of these meteorites and compared with the activities of 14 C, 26 Al, and 36 Cl measured by other workers in terrestrial age studies. A good correlation was found between the TL levels and the activities of cosmogenic radionuclides in these meteorites. Since the TL measurements can be made more rapidly and require much smaller samples (approx. 10 mg) than the radionuclide measurements, TL is most useful as a screening process to select potentially interesting samples for further study by more precise techniques

  17. The superconductor (Tl,Hg,Ca)2(Ba,Sr)2(Ca,Sr,Tl)Cu2O7.6

    International Nuclear Information System (INIS)

    Valldor, M.; Bryntse, I.; Morawski, A.

    2002-01-01

    In the title 2212-type superconductor (thallium mercury calcium barium strontium copper oxide), which contains both Tl and Hg in the charge reservoir (CR), Sr is located at both alkali-earth (AE) metal sites. Ca enters the CR at the same time as Tl shares the smaller AE site, which increases the apical Cu-Cu distance significantly. The structure causes the superconducting Cu-O layers to become significantly puckered. (orig.)

  18. The TL and OSL study of hydroxyapatites for dosimetric applications

    International Nuclear Information System (INIS)

    Alencar, Marcus A. Vallim de

    2009-01-01

    The hydroxyapatite, the principal mineral component of the bone and tooth enamel, is one of the dosimetric materials that has distinguished itself in the high dose and accidents dosimetry, as well as in the dating, for the Electron Paramagnetic Resonance (EPR) technique. For this reason, the hydroxyapatite could also be used as Thermoluminescence (TL) and Optically Stimulated Luminescence (OSL) dosimeter in the dosimetry of high doses and accidents, and also in the archaeological and geological dating. This work presents a brief study of the TL and OSL behaviour of the B type synthetic carbonated hydroxyapatite, observing the possibility to use this material in TL and OSL dosimetry. The samples were irradiated to a dose of 100 Gy and 1000 Gy, and the TL and OSL measurements were obtained by the RISOE TL/OSL reader, model TL/OSL-DA-15B. The first results demonstrate the presence of three peaks in the TL glow curve in the temperatures of 100 deg C, 150 deg C and 280 deg C. The synthetic carbonated hydroxyapatite also presents an OSL signal when the sample is stimulated with blue light and a small OSL signal for stimulation with infrared light (IR). These results indicate the possibility of this synthetic carbonated hydroxyapatite to be used as dose indicator material using the TL and OSL techniques. (author)

  19. Kinetic parameters and TL mechanism in cadmium tetra borate phosphor

    International Nuclear Information System (INIS)

    Annalakshmi, O.; Jose, M.T.; Sridevi, J.; Venkatraman, B.; Amarendra, G.; Mandal, A.B.

    2014-01-01

    Polycrystalline powder samples of cadmium tetra borate were synthesized by a simple solid state sintering technique and gamma irradiated sample showed a simple Thermoluminescence (TL) glow peak around 460 K. The TL kinetic parameters of gamma irradiated phosphor were determined by initial rise (IR), isothermal decay (ID), peak shape (PS), variable heating rate (VHR) and glow curve de-convolution method. The kinetic parameters such as activation energy (E), frequency factor (s) and order of kinetics (b) were calculated by IR, ID, PS and VHR methods are in the order of ∼1.05 eV, 10 9 –10 12 s −1 and 1.58, respectively. From the results of TL and PL emission studies carried out on the phosphor revealed that the defect centers related to TL is different from that for PL. EPR measurements were carried out to identify the defect centers formed in cadmium tetra borate phosphor on gamma irradiation. Based on EPR studies the mechanism for TL process in cadmium tetra borate is proposed in this paper -- Highlights: • Polycrystalline powder samples of undoped cadmium tetra borate synthesized. • Cadmium tetra borate phosphor exhibits a dosimetric peak at 458 K. • Kinetic parameters of the trap responsible for TL evaluated. • TL mechanism is proposed from TL to EPR correlation studies

  20. Kinetic parameters and TL mechanism in cadmium tetra borate phosphor

    Energy Technology Data Exchange (ETDEWEB)

    Annalakshmi, O. [Radiological Safety Division, Materials Physics Division, Indira Gandhi Centre for Atomic Research, Kalpakkam-603102 (India); Jose, M.T., E-mail: mtj@igcar.gov.in [Radiological Safety Division, Materials Physics Division, Indira Gandhi Centre for Atomic Research, Kalpakkam-603102 (India); Sridevi, J. [Central Leather Research Institute, Council of Scientific and Industrial Research, Chennai 600 020, Tamilnadhu (India); Venkatraman, B. [Radiological Safety Division, Materials Physics Division, Indira Gandhi Centre for Atomic Research, Kalpakkam-603102 (India); Amarendra, G. [Materials Physics Division, Indira Gandhi Centre for Atomic Research, Kalpakkam-603102 (India); Mandal, A.B. [Central Leather Research Institute, Council of Scientific and Industrial Research, Chennai 600 020, Tamilnadhu (India)

    2014-03-15

    Polycrystalline powder samples of cadmium tetra borate were synthesized by a simple solid state sintering technique and gamma irradiated sample showed a simple Thermoluminescence (TL) glow peak around 460 K. The TL kinetic parameters of gamma irradiated phosphor were determined by initial rise (IR), isothermal decay (ID), peak shape (PS), variable heating rate (VHR) and glow curve de-convolution method. The kinetic parameters such as activation energy (E), frequency factor (s) and order of kinetics (b) were calculated by IR, ID, PS and VHR methods are in the order of ∼1.05 eV, 10{sup 9}–10{sup 12} s{sup −1} and 1.58, respectively. From the results of TL and PL emission studies carried out on the phosphor revealed that the defect centers related to TL is different from that for PL. EPR measurements were carried out to identify the defect centers formed in cadmium tetra borate phosphor on gamma irradiation. Based on EPR studies the mechanism for TL process in cadmium tetra borate is proposed in this paper -- Highlights: • Polycrystalline powder samples of undoped cadmium tetra borate synthesized. • Cadmium tetra borate phosphor exhibits a dosimetric peak at 458 K. • Kinetic parameters of the trap responsible for TL evaluated. • TL mechanism is proposed from TL to EPR correlation studies.

  1. The influence of radiation-induced defects on thermoluminescence and optically stimulated luminescence of α-Al_2O_3:C

    International Nuclear Information System (INIS)

    Nyirenda, A.N.; Chithambo, M.L.

    2017-01-01

    It is known that when α-Al_2O_3:C is exposed to excessive amounts of ionising radiation, defects are induced within its matrix. We report the influence of radiation-induced defects on the thermoluminescence (TL) and optically stimulated luminescence (OSL) measured from α-Al_2O_3:C after irradiation to 1000 Gy. These radiation-induced defects are thermally unstable in the region 450–650 °C and result in TL peaks in this range when the TL is measured at 1 °C/s. Heating a sample to 700 °C obliterates the radiation-induced defects, that is, the TL peaks corresponding to the radiation induced defects are no longer observed in the subsequent TL measurements when moderate irradiation doses below 10 Gy are used. The charge traps associated with these radiation-induced defects are more stable than the dosimetric trap when the sample is exposed to either sunlight or 470-nm blue light from LEDs. TL glow curves measured following the defect-inducing irradiation produce a dosimetric peak that is broader and positioned at a higher temperature than observed in glow curves obtained before the heavy irradiation. In addition, sample sensitization/desensitization occurs due to the presence of these radiation-induced defects. Furthermore, both the activation energy and the kinetic order of the dosimetric peak evaluated when the radiation-induced defects are present in the sample are significantly lower in value than those obtained when these defects are absent. The radiation-induced defects also affect the shape and total light sum of the OSL signal as well as the position and width of the resultant residual phototransferred thermoluminescence main peak.

  2. The nonlinear light output of NaI(Tl) detectors in the Modular Total Absorption Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Rasco, B.C., E-mail: crasco@lsu.edu [Department of Physics and Astronomy, Louisiana State University, Baton Rouge, LA 70803 (United States); Fijałkowska, A.; Karny, M. [Faculty of Physics, University of Warsaw, Pasteura 5, PL-02093 Warszawa (Poland); Rykaczewski, K.P. [Physics Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Wolińska-Cichocka, M. [Physics Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Oak Ridge Associated Universities, Oak Ridge, TN 37831 (United States); Heavy Ion Laboratory, University of Warsaw, Warsaw PL-02-093 (Poland); Grzywacz, R.; Goetz, K.C. [Department of Physics and Astronomy, University of Tennessee, Knoxville, TN 37966 (United States)

    2015-07-11

    A new detector array, the Modular Total Absorption Spectrometer (MTAS), was commissioned at the Holifield Radioactive Ion Beam Facility (HRIBF) at Oak Ridge National Lab (ORNL). Total absorption gamma spectra measured with MTAS are expected to improve beta-feeding patterns and beta strength functions in fission products. MTAS is constructed out of hexagonal NaI(Tl) detectors with a unique central module surrounded by 18 identical crystals assembled in three rings. The total NaI(Tl) mass of MTAS is over 1000 kg. The response of the central and other 18 MTAS modules to γ-radiation was simulated using the GEANT4 toolkit modified to analyze the nonlinear light output of NaI(Tl). A detailed description of the GEANT4 modifications made is discussed. Simulated energy resolution of MTAS modules is found to agree well with the measurements for single γ transitions of 662 keV ({sup 137}Cs) with 8.2% full width half maximum (FWHM), 835 keV ({sup 54}Mn) with FWHM of 7.5% FWHM, and 1115 keV ({sup 65}Zn) with FWHM of 6.5%. Simulations of single and multiple γ-rays from {sup 60}Co are also discussed.

  3. Radiation dosimetry for medical management in nuclear/radiological disaster

    International Nuclear Information System (INIS)

    Narayan, Pradeep

    2012-01-01

    Medical Management of radiation exposed victims depends on the amount of radiation doses received in their body and individual organs. The severity of radiation sickness; and early/late biological effects of radiation can be judged on the basis of absorbed dose level of the exposed individual. Radiation Dosimetry is a scientific technique for estimating radiation doses in material and living being. It is an important task for managing radiation effects/injuries to the living being in case of radiological accidents/disasters. In such scenario occupational radiation workers as well as public in general may be exposed with ionizing radiations such as; gamma, alpha, beta and neutron. Radiation dosimetric equipment's are available for occupational radiation workers, however, public in general may not have any dosimetry system with them. Therefore, absorbed dose estimation to the public on individual basis is a challenge to the society. The ambient environment materials in close proximity to the exposed individual may be analyzed using scientific techniques to estimate their personal radiation doses. The blood sample from exposed individual can be examined in laboratory using citometry techniques for dose estimation, however these techniques are very time consuming and may not be suitable for quick radiation management. The other human biological material such as; tooth, hair, and bone etc., can be examined using Electron Spin Resonance (ESR) spectrometry techniques. This technique is very efficient and capable in measuring radiation doses of the order of 20-30 mGy in very less time typically 2-3 min. In reality, this technique is costly affair and available mostly in developed countries. Thermoluminescence (TL) technique is very versatile and cost effective for routine personal dose estimation, This technique has been found suitable for measuring TL in many accidentally exposed environmental materials. The radiation exposed natural environmental materials, such as

  4. Dosimetric characterization of chemical-vapor-deposited diamond film irradiated with UV and beta radiation

    Science.gov (United States)

    Meléndrez, R.; Chernov, V.; Pedroza-Montero, M.; Barboza-Flores, M.

    2003-03-01

    Diamond is an excellent prospect for clinical radiation dosimetry due to its tissue-equivalence properties and being chemically inert. The use of diamond in radiation dosimetry has been halted by the high market price; although recently the capability of growing high quality polycrystalline has renewed the interest in using diamond films as detectors and dosimeters. In the present work we have characterized the dosimetric properties of diamond films synthesized by using chemical vapor deposition. The thermoluminescence (TL) of UV and beta exposed samples shows a glow curve composed of at least four peaks; one located around 587 K presents excellent TL properties suitable for dosimetric applications with ionizing and non ionizing radiation. The TL excitation spectrum exhibits maximum TL efficiency at 220 nm. The samples show regions of linear as well as supralinear behavior as a function or irradiation dose. The linear dose dependence was found for up to sixteen minutes of UV irradiation and 300 Gy for beta irradiated samples. The activation energy and the frequency factor were determined and found in the range of 0.32 - 0.89 eV and 1.1x10^2 - 2x10^8s_-1, respectively. The observed TL performance is reasonable appropriate to justify further investigation of diamond films as radiation dosimeters.

  5. Dosimetric characterization of BeO samples in alpha, beta and X radiation beams using luminescent techniques

    International Nuclear Information System (INIS)

    Groppo, Daniela Piai

    2013-01-01

    In the medical field, the ionizing radiation is used both for therapeutic and diagnostic purposes, in a wide range of radiation doses. In order to ensure that the objective is achieved in practice, detailed studies of detectors and devices in different types of radiations beams are necessary. In this work a dosimetric characterization of BeO samples was performed using the techniques of thermoluminescence (TL) and optically stimulated luminescence (OSL) by a comparison of their response for alpha, beta and X radiations and the establishment of an appropriated system for use in monitoring of these radiations beams. The main results are: the high sensitivity to beta radiation for both techniques, good reproducibility of TL and OSL response (coefficients of variation lower than 5%), maximum energy dependence of the X radiation of 28% for the TL technique, and only 7% for the OSL technique, within the studied energy range. The dosimetric characteristics obtained in this work show the possibility of applying BeO samples to dosimetry of alpha, beta and X radiations, considering the studied dose ranges, using the TL and OSL techniques. From the results obtained, the samples of BeO showed their potential use for beam dosimetry in diagnostic radiology and radiotherapy. (author)

  6. Evaluation of the substitution of PMMA plates by PLA 3D printed in TL response of CaSO_4:Dy

    International Nuclear Information System (INIS)

    Almeida, Shirlane Barbosa de; Valeriano, Caio Cesar Santos; Campos, Leticia Lucente

    2016-01-01

    The CaSO_4:Dy is a dosimetric material that is nationally produced, which presents high sensibility but a high energy dependence of its thermoluminescent (TL) response at the photoelectric effect region. This study aims to compare the TL response of the CaSO_4:Dy when irradiated, with different energies, at the presence of 3D printed plates of polylactic acid (PLA) and polymethylmethacrylate (PMMA). Results show that the PLA has a different attenuation of the radiation, when compared to PMMA, indicating that it should be taken into account the quality of the print used on PLA plates manufacture. (author)

  7. 205Tl experiment

    International Nuclear Information System (INIS)

    Henning, W.; Kutschera, W.; Ernst, H.

    1984-01-01

    205 Tl has been previously proposed as a geological detector for solar neutrinos, making use of the reaction 205 Tl(nu, e - ) 205 Pb with a neutrino threshold of only approx. = 43 keV. We report on an experiment performed to study the feasibility of detecting radioactive 205 Pb nuclei (T/sub 1/2/ = 15 million years) at very low concentrations using the recently developed technique of accelerator mass spectrometry. Employing the high-energy ion beams of good quality from the UNILAC heavy-ion accelerator at the GSI Darmstadt, we are able to demonstrate a suppression of neighbouring isotopes to better than 1 in 10 16 and of neighbouring elements to about 1 in 10 3 . While these results are very encouraging, the minimum number of atoms detectable is still severely limited by the efficiency of producing multiply-charged ions from present ion sources. Future improvements in ion-source performance are briefly discussed

  8. Thermoluminescent study of the hydroxyapatite irradiated with gamma radiation

    International Nuclear Information System (INIS)

    Mendoza A, D.; Hernandez A, M.; Gonzalez, P.R.; Rodriguez L, V.

    2002-01-01

    Recently in dosimetry, it has been common to use bones and teeth for detecting and measuring radiation. However it has been observed that the efficiency of detection depends on the consistency of these tissues. Since the hydroxyapatite [Ca 10 (PO 4 ) 6 (OH) 2 ] is the main mineral component of the bones and teeth, it has been suggested as material for detecting and measuring of radiations, quantifying the free radicals produced by radiation. In this work a study about the thermoluminescent properties (Tl) induced by radiation in the synthetic hydroxyapatite obtained by hydrothermal method is presented. The results have shown that this mineral presents a Tl signal whose curve contains two maximums located around 150 and 250 C degrees, respectively. Likewise, a linear behavior of the Tl signal of function of dose in the interval 10-100 Gy was observed. These results are important since that they open the possibility to use biomaterials in the dosimetric area, when they only were used for grafting in the biomedical area. (Author)

  9. Detailed α -decay study of 180Tl

    Science.gov (United States)

    Andel, B.; Andreyev, A. N.; Antalic, S.; Barzakh, A.; Bree, N.; Cocolios, T. E.; Comas, V. F.; Diriken, J.; Elseviers, J.; Fedorov, D. V.; Fedosseev, V. N.; Franchoo, S.; Ghys, L.; Heredia, J. A.; Huyse, M.; Ivanov, O.; Köster, U.; Liberati, V.; Marsh, B. A.; Nishio, K.; Page, R. D.; Patronis, N.; Seliverstov, M. D.; Tsekhanovich, I.; Van den Bergh, P.; Van De Walle, J.; Van Duppen, P.; Venhart, M.; Vermote, S.; Veselský, M.; Wagemans, C.

    2017-11-01

    A detailed α -decay spectroscopy study of 180Tl has been performed at ISOLDE (CERN). Z -selective ionization by the Resonance Ionization Laser Ion Source (RILIS) coupled to mass separation provided a high-purity beam of 180Tl. Fine-structure α decays to excited levels in the daughter 176Au were identified and an α -decay scheme of 180Tl was constructed based on an analysis of α -γ and α -γ -γ coincidences. Multipolarities of several γ -ray transitions deexciting levels in 176Au were determined. Based on the analysis of reduced α -decay widths, it was found that all α decays are hindered, which signifies a change of configuration between the parent and all daughter states.

  10. Comparison of TL profiles in recent sea cores

    Energy Technology Data Exchange (ETDEWEB)

    Castagnoli, G C; Bonino, G

    1985-01-01

    The thermoluminescence (TL) profile of different recent Tyrrhenian sea cores sampled at various intervals during the last centuries have been compared in order to check the reproducibility of the profiles and investigate the possibility of using the results for monitoring solar-terrestrial relations in the past. The satisfactory results obtained by comparison of two different cores in the time interval 1755-1969 A.D. has demonstrated: (a) the two TL profiles are correlated; (b) the 11 yr cycle corresponding to the main solar cycle is evident in both TL profiles.

  11. The adsorption of Tl(I), Au(III), Cu(II) and the separation of 199Tl from alpha bombardment of gold target with PDB-18C6

    International Nuclear Information System (INIS)

    Zhou Dehai; Zhou Jimeng

    1989-01-01

    The adsorptive behavior of polymer of methyl aldehyde of dibenzo-18-crown-6 (PDB-18C6) in hydrochloric acid medium is studied and it is shown that the adsorption of T1(I), Au(III), and Cu(II) depends on the particle size of the crown ether resins, hydrochloric acid concentration and amount of the crown ether resins used. The difference in the adsorption behavior of different particle sizes of crown ether resins may be used for separating Tl(I), Au(III), and Cu(II) ions. The best eluant of Tl(I) and Au(III) is 0.4 mol/l perchloric acid and 2-ethoxy-ethanol. The recovery for Tl(I) is 82-98.8%. The gold target is bombarded in a 1.2 m cyclotron with 25-27 MeV α-particle with a cumulative beam intensities of 27μA·h, and 199 Tl is separated from the gold target with PDB-18C6. γ-spectrometry has shown that the Tl obtained is 199 Tl of high purity containing only about 0.50% 200 Tl

  12. Immunologic mechanism of the suppressive effect of low dose radiation on thymic lymphoma induced by radiation

    International Nuclear Information System (INIS)

    Li Xiujuan; Yang Ying; Li Xiuyi; Liu Shuzheng

    1999-01-01

    To study immunologic mechanism of the suppressive effect of low dose radiation (LDR) on thymic lymphoma (TL) induced by high dose radiation (HDR). The authors adopted the model that C57BL/6J mice were administered whole body irradiation with 1.75 Gy X-rays one time every week for 4 weeks to induce TL. It was examined that splenic NK cytotoxic activity, IL-2 and γ-IFN secretion activity, peritoneal macrophage phagocytosis and its TNF-α secretion activity in mice with different dose 1 month after irradiation. The results showed that all the immunologic functions mentioned above in mice given 75 mGy 12 h before 1.75 Gy every time were higher than that in mice given only 1.75 Gy, and approached to the sham-irradiation mice. It suggested that the suppressive effect of LDR on TL induced by HDR may be related to the adaptive response induced by LDR and decreasing immunological functions damage caused by HDR

  13. How Experienced SoTL Researchers Develop the Credibility of Their Work

    Directory of Open Access Journals (Sweden)

    Jennie Billot

    2017-03-01

    Full Text Available Teaching and learning research in higher education, often referred to as the Scholarship of Teaching and Learning (SoTL, is still relatively novel in many academic contexts compared to the mainstay of disciplinary research. One indication of this is the challenges those who engage in SoTL report in terms of how this work is valued or considered credible amongst disciplinary colleagues and in the face of institutional policies and practices. This paper moves beyond the literature that describes these specific challenges to investigate how 23 experienced SoTL researchers from five different countries understood the notion of credibility in relationship to their SoTL research and how they went about developing credibility for their work. Semi-structured interviews were facilitated and analyzed using inductive analysis. Findings indicate that notions of credibility encompassed putting SoTL research into action and building capacity and community around research findings, as well as gaining external validation through traditional indicators such as publishing. SoTL researchers reported a variety of strategies and approaches they were using, both formal and informal, to develop credibility for their work. The direct focus of this paper on credibility of SoTL work as perceived by experienced SoTL researchers, and how they go about developing credibility, is a distinct contribution to the discussions about the valuing of SoTL work.

  14. Two cases of hyperparathyroidism revealed by /sup 201/Tl-chloride

    Energy Technology Data Exchange (ETDEWEB)

    Otsuka, Kokichi; Asano, Haruko; Moriyama, Shigeharu (Okayama Red Cross Hospital (Japan))

    1983-08-01

    /sup 201/Tl scintigraphy at 15 min and 120 min after intravenous injection of /sup 201/TlCl revealed a parathyroidal adenoma (1.7g) in a 49-year-old female patient with hyperthyroidism complicated by renal calculi and that (1.8g) in a 58-year-old female patient without symptoms. /sup 75/Se could be substituted by /sup 201/Tl which was useful for localizing parathyroidal adenoma in hyperparathyroidism. /sup 201/Tl scintigraphy revealed the adenoma which was not palpable. The smallest adenoma detected by it was 0.9g.

  15. Methods, qualitative and quantitative evaluations of 201Tl myocardial scintiscans

    International Nuclear Information System (INIS)

    Buell, U.; Kleinhans, E.; Klepzig, M.; Seiderer, M.; Strauer, B.E.

    1981-01-01

    Exercise 201 Tl myocardial scintiscanning is a technique used to supplement exercise electrocardiography. The procedure employed should be identical to the standard procedure of electrocardiography. If the coronary disease has already been established by coronary angiography and kineventriculography, 201 Tl examinations should be carried out before surgery in order to determine the ''regional functional reserve''. Visual evaluations of the 201 Tl scintiscans should be supplemented by quantification methods. Quantification is also required between 201 Tl examination and surgery and to assure constant diagnostic accuracy in case of examination by different examiners. (orig./MG) [de

  16. Electronic structure of TlBa2CaCu2O7-δ

    Science.gov (United States)

    Vasquez, R. P.; Novikov, D. L.; Freeman, A. J.; Siegal, M. P.

    1997-06-01

    The core levels of TlBa2CaCu2O7-δ (Tl-1212) epitaxial films have been measured with x-ray photoelectron spectroscopy (XPS). The valence electronic structure has been determined using the full-potential linear muffin-tin-orbital band-structure method and measured with XPS. The calculations show that a van Hove singularity (VHS) lies above the Fermi level (EF) for the stoichiometric compound (δ=0), while for 50% oxygen vacancies in the Tl-O layer (δ=0.5) EF is in close proximity to the VHS. Samples annealed in nitrogen (to reduce the hole overdoping by the removal of oxygen) exhibit higher core-level binding energies and a higher Tc, consistent with a shift of EF closer to the VHS. Comparisons are made to the core levels and valence bands of Tl2Ba2CaCu2O8+δ (Tl-2212) and HgBa2CaCu2O6+δ (Hg-1212). The similarity of the Cu 2p3/2 spectra for Tl-1212 and Tl-2212 indicates that the number of Tl-O layers has little effect on the Cu-O bonding. However, the Tl-1212 and Hg-1212 Cu 2p3/2 signals exhibit differences which suggest that the replacement of Tl3+ with Hg2+ results in a decrease in the O 2p-->Cu 3d charge-transfer energy and differences in the probabilities of planar vs apical oxygen charge transfer and/or Zhang-Rice singlet-state formation. Differences between the Tl-1212 and the Tl-2212 and Hg-1212 measured valence bands are consistent with the calculated Cu 3d and (Tl,Hg) 6s/5d partial densities of states.

  17. Electronic structure of TlBa2CaCu2O7-δ

    International Nuclear Information System (INIS)

    Vasquez, R.P.; Novikov, D.L.; Freeman, A.J.; Siegal, M.P.

    1997-01-01

    The core levels of TlBa 2 CaCu 2 O 7-δ (Tl-1212) epitaxial films have been measured with x-ray photoelectron spectroscopy (XPS). The valence electronic structure has been determined using the full-potential linear muffin-tin-orbital band-structure method and measured with XPS. The calculations show that a van Hove singularity (VHS) lies above the Fermi level (E F ) for the stoichiometric compound (δ=0), while for 50% oxygen vacancies in the Tl-O layer (δ=0.5) E F is in close proximity to the VHS. Samples annealed in nitrogen (to reduce the hole overdoping by the removal of oxygen) exhibit higher core-level binding energies and a higher T c , consistent with a shift of E F closer to the VHS. Comparisons are made to the core levels and valence bands of Tl 2 Ba 2 CaCu 2 O 8+δ (Tl-2212) and HgBa 2 CaCu 2 O 6+δ (Hg-1212). The similarity of the Cu 2p 3/2 spectra for Tl-1212 and Tl-2212 indicates that the number of Tl-O layers has little effect on the Cu-O bonding. However, the Tl-1212 and Hg-1212 Cu 2p 3/2 signals exhibit differences which suggest that the replacement of Tl 3+ with Hg 2+ results in a decrease in the O 2p→Cu 3d charge-transfer energy and differences in the probabilities of planar vs apical oxygen charge transfer and/or Zhang-Rice singlet-state formation. Differences between the Tl-1212 and the Tl-2212 and Hg-1212 measured valence bands are consistent with the calculated Cu 3d and (Tl,Hg) 6s/5d partial densities of states. copyright 1997 The American Physical Society

  18. TL response to quartz and aluminum oxide grain for α-irradiation

    International Nuclear Information System (INIS)

    Pan Baolin; Wei Mingjian; Li Dongxu; Liu Zhaowen; Liu Chao; Zhao Shiyuan

    2009-01-01

    Thermoluminescence (TL) response for an α-ray irradiation system ( 241 Am) was examined with quartz grains of 11-40 μm. Quartz grains of different sizes, i.e. 137 Cs), before they were irradiated to different doses by the α-ray irradiation system. TL response to the quartz grain samples was measured. TL response of the quartz grains smaller than 4 μm and 11-40 μm to α-ray irradiation is the best, as the α-rays cannot penetrate quartz larger than 40 μm. The TL response characteristic is related with quartz grain surface area. TL responses to α-irradiation of 11-40 μm quartz and aluminum oxide grains were compared. The α-irradiation TL response of aluminum oxide (330 degree C) is better than the quartz (375 degree C). (authors)

  19. A Call for Expanding Inclusive Student Engagement in SoTL

    Directory of Open Access Journals (Sweden)

    Peter Felten

    2013-09-01

    of student-faculty partnerships focused on inquiry into teaching and learning. However, some students tend to be privileged in SoTL initiatives while others are discouraged, implicitly or explicitly, from engaging in this work. In this paper, we consider why certain students tend to be excluded from SoTL, summarize the possible developmental gains made by students and faculty when diverse student voices are included, and highlight strategies for generating a more inclusive SoTL. We call for expanding student engagement in SoTL by encouraging a diversity of student voices to engage in co-inquiry with faculty. Inclusive engagement has tremendous potential to enhance student and faculty learning, to deepen SoTL initiatives, and to help redress the exclusionary practices that too often occur in higher education.

  20. Conceptualizing and Communicating SoTL: A Framework for the Field

    Directory of Open Access Journals (Sweden)

    Janice Miller-Young

    2015-09-01

    Full Text Available The emerging field of SoTL is an inherently interdisciplinary endeavor which requires embracing a diverse range of research methods and disciplinary differences in world views. This diversity has caused a lack of coherence in its conceptualization and communication, which can be confusing for new scholars. Ongoing debates in the community concern the use of theory and methodology, as well as definitional questions of what constitutes SoTL and the nature of its purpose. This article offers a framework for conceptualizing the field which attempts to broadly delineate the available learning theories underlying and methodologies appropriate to studying teaching and learning, while intending to be hospitable to a broad range of diverse disciplines. Further, the framework illustrates the tacit links between learning theories and methodologies, serving as a guide to potential approaches to SoTL work. The framework is illustrated with example SoTL studies. It is hoped that the framework will help ground future SoTL investigations in appropriate theories and methodologies, and build interdisciplinary communication and understanding in the “trading zone” that is SoTL.

  1. The influence of radiation-induced defects on thermoluminescence and optically stimulated luminescence of α-Al{sub 2}O{sub 3}:C

    Energy Technology Data Exchange (ETDEWEB)

    Nyirenda, A.N., E-mail: anyirenda@gmail.com; Chithambo, M.L.

    2017-04-15

    It is known that when α-Al{sub 2}O{sub 3}:C is exposed to excessive amounts of ionising radiation, defects are induced within its matrix. We report the influence of radiation-induced defects on the thermoluminescence (TL) and optically stimulated luminescence (OSL) measured from α-Al{sub 2}O{sub 3}:C after irradiation to 1000 Gy. These radiation-induced defects are thermally unstable in the region 450–650 °C and result in TL peaks in this range when the TL is measured at 1 °C/s. Heating a sample to 700 °C obliterates the radiation-induced defects, that is, the TL peaks corresponding to the radiation induced defects are no longer observed in the subsequent TL measurements when moderate irradiation doses below 10 Gy are used. The charge traps associated with these radiation-induced defects are more stable than the dosimetric trap when the sample is exposed to either sunlight or 470-nm blue light from LEDs. TL glow curves measured following the defect-inducing irradiation produce a dosimetric peak that is broader and positioned at a higher temperature than observed in glow curves obtained before the heavy irradiation. In addition, sample sensitization/desensitization occurs due to the presence of these radiation-induced defects. Furthermore, both the activation energy and the kinetic order of the dosimetric peak evaluated when the radiation-induced defects are present in the sample are significantly lower in value than those obtained when these defects are absent. The radiation-induced defects also affect the shape and total light sum of the OSL signal as well as the position and width of the resultant residual phototransferred thermoluminescence main peak.

  2. TlHgInS 3 : An Indirect-Band-Gap Semiconductor with X-ray Photoconductivity Response

    Energy Technology Data Exchange (ETDEWEB)

    Li, Hao; Malliakas, Christos D.; Han, Fei; Chung, Duck Young; Kanatzidis, Mercouri G.

    2015-08-11

    The quaternary compound TlHgInS3 crystallizes in a new structure type of space group, C2/c, with cell parameters a = 13.916(3) angstrom, b = 3.9132(8) angstrom, c = 21.403(4) angstrom, beta = 104.16(3)degrees, V = 1130.1(8) angstrom(3), and rho = 7.241 g/cm(3). The structure is a unique three-dimensional framework with parallel tunnels, which is formed by (1)(infinity)[InS33-] infinite chains bridged by linearly coordinated Hg2+ ions. TlHgInS3 is a semiconductor with a band gap of 1.74 eV and a resistivity of similar to 4.32 G Omega cm. TlHgInS3 single crystals exhibit photocurrent response when exposed to Ag X-rays. The mobility-lifetime product (mu tau) of the electrons and holes estimated from the photocurrent measurements are (mu tau)(e) approximate to 3.6 x 10(-4) cm(2)/V and (mu tau)(h) approximate to 2.0 x 10(-4) cm(2)/V. Electronic structure calculations at the density functional theory level indicate an indirect band gap and a relatively small effective mass for both electrons and holes. Based on the photoconductivity data, TlHgInS3 is a potential material for radiation detection applications.

  3. Prediction of Phase Separation of Immiscible Ga-Tl Alloys

    Science.gov (United States)

    Kim, Yunkyum; Kim, Han Gyeol; Kang, Youn-Bae; Kaptay, George; Lee, Joonho

    2017-06-01

    Phase separation temperature of Ga-Tl liquid alloys was investigated using the constrained drop method. With this method, density and surface tension were investigated together. Despite strong repulsive interactions, molar volume showed ideal mixing behavior, whereas surface tension of the alloy was close to that of pure Tl due to preferential adsorption of Tl. Phase separation temperatures and surface tension values obtained with this method were close to the theoretically calculated values using three different thermodynamic models.

  4. Thermoluminescence dependence on the wavelength of monochromatic UV-radiation in Cu-doped KCl and KBr at room temperature

    Energy Technology Data Exchange (ETDEWEB)

    Perez R, A.; Piters, T.; Aceves, R.; Rodriguez M, R.; Perez S, R., E-mail: rperez@cifus.uson.mx [Universidad de Sonora, Departamento de Investigaciones en Fisica, Apdo. Postal 5-088, 83190 Hermosillo, Sonora (Mexico)

    2014-08-15

    Thermoluminescence (Tl) dependence on the UV irradiation wavelengths from 200 to 500 nm in Cu-doped KCl and KBr crystals with different thermal treatment has been analyzed. Spectrum of the Tl intensity of each material show lower intensity at wavelengths longer than 420 nm. The Tl intensity depends on the irradiation wavelength. Structure of the Tl intensity spectrum of each sample is very similar to the structure of its optical absorption spectrum, indicating that at each wavelength, monochromatic radiation is absorbed to produce electronic transitions and electron hole pairs. Thermoluminescence of materials with thermal treatment at high temperature shows electron-hole trapping with less efficiency. The results show that Cu-doped alkali-halide materials are good detectors of a wide range of UV monochromatic radiations and could be used to measure UV radiation doses. (Author)

  5. Thermoluminescence dependence on the wavelength of monochromatic UV-radiation in Cu-doped KCl and KBr at room temperature

    International Nuclear Information System (INIS)

    Perez R, A.; Piters, T.; Aceves, R.; Rodriguez M, R.; Perez S, R.

    2014-08-01

    Thermoluminescence (Tl) dependence on the UV irradiation wavelengths from 200 to 500 nm in Cu-doped KCl and KBr crystals with different thermal treatment has been analyzed. Spectrum of the Tl intensity of each material show lower intensity at wavelengths longer than 420 nm. The Tl intensity depends on the irradiation wavelength. Structure of the Tl intensity spectrum of each sample is very similar to the structure of its optical absorption spectrum, indicating that at each wavelength, monochromatic radiation is absorbed to produce electronic transitions and electron hole pairs. Thermoluminescence of materials with thermal treatment at high temperature shows electron-hole trapping with less efficiency. The results show that Cu-doped alkali-halide materials are good detectors of a wide range of UV monochromatic radiations and could be used to measure UV radiation doses. (Author)

  6. Ionising radiation effect on the luminescence emission of inorganic and biogenic calcium carbonates

    Energy Technology Data Exchange (ETDEWEB)

    Boronat, C. [CIEMAT, Av. Complutense 40, Madrid 28040 (Spain); Correcher, V., E-mail: v.correcher@ciemat.es [CIEMAT, Av. Complutense 40, Madrid 28040 (Spain); Virgos, M.D. [CIEMAT, Av. Complutense 40, Madrid 28040 (Spain); Garcia-Guinea, J. [CSIC, Museo Nacional Ciencias Naturales, José Gutiérrez Abascal 2, Madrid 28006 (Spain)

    2017-06-15

    Highlights: • Aragonite and biogenic Ca-carbonates could be used as a TL dosimeters. • TL can be employed for retrospective dosimetry purposes. • Calcium carbonates show an acceptable ionizing radiation sensitivity. • The stability of the radiation–induced TL remains, at least, till 700 h. - Abstract: As known, the luminescence emission of mineral phases could be potentially employed for dosimetric purposes in the case of radiological terrorism or radiation accident where conventional monitoring is not available. In this sense, this paper reports on the thermo- (TL) and cathodoluminescence (CL) emission of both biogenic (common periwinkle – littorina littorera – shell made of calcite 90% and aragonite 10%) and inorganic (aragonite 100%) Ca-rich carbonates previously characterized by X-ray diffraction and Raman spectroscopy. Whereas the aragonite sample displays the main CL waveband peaked in the red region (linked to point defects), the more intense emission obtained from the common periwinkle shell appears at higher energies (mainly associated with structural defects). The UV-blue TL emission of the samples, regardless of the origin, displays (i) an acceptable ionizing radiation sensitivity, (ii) linear dose response in the range of interest (up to 8 Gy), (iii) reasonable stability of the TL signal after 700 h of storage with an initial decay of ca. 88% for the mineral sample and 60% for the biogenic sample and maintaining the stability from 150 h onwards. (iv) The tests of thermal stability of the TL emission performed in the range of 180–320 °C confirm a continuum in the trap system.

  7. Ionising radiation effect on the luminescence emission of inorganic and biogenic calcium carbonates

    International Nuclear Information System (INIS)

    Boronat, C.; Correcher, V.; Virgos, M.D.; Garcia-Guinea, J.

    2017-01-01

    Highlights: • Aragonite and biogenic Ca-carbonates could be used as a TL dosimeters. • TL can be employed for retrospective dosimetry purposes. • Calcium carbonates show an acceptable ionizing radiation sensitivity. • The stability of the radiation–induced TL remains, at least, till 700 h. - Abstract: As known, the luminescence emission of mineral phases could be potentially employed for dosimetric purposes in the case of radiological terrorism or radiation accident where conventional monitoring is not available. In this sense, this paper reports on the thermo- (TL) and cathodoluminescence (CL) emission of both biogenic (common periwinkle – littorina littorera – shell made of calcite 90% and aragonite 10%) and inorganic (aragonite 100%) Ca-rich carbonates previously characterized by X-ray diffraction and Raman spectroscopy. Whereas the aragonite sample displays the main CL waveband peaked in the red region (linked to point defects), the more intense emission obtained from the common periwinkle shell appears at higher energies (mainly associated with structural defects). The UV-blue TL emission of the samples, regardless of the origin, displays (i) an acceptable ionizing radiation sensitivity, (ii) linear dose response in the range of interest (up to 8 Gy), (iii) reasonable stability of the TL signal after 700 h of storage with an initial decay of ca. 88% for the mineral sample and 60% for the biogenic sample and maintaining the stability from 150 h onwards. (iv) The tests of thermal stability of the TL emission performed in the range of 180–320 °C confirm a continuum in the trap system.

  8. Stability of Tl-Ba-Ca-Cu-O superconducting thin films

    International Nuclear Information System (INIS)

    Siegal, M. P.; Overmyer, D. L.; Venturini, E. L.; Padilla, R. R.; Provencio, P. N.

    1999-01-01

    We report the stability of TlBa 2 CaCu 2 O 7 and Tl 2 Ba 2 CaCu 2 O 8 on LaAlO 3 (100) epitaxial thin films, under a variety of conditions. All films are stable in acetone and methanol and with repeated thermal cycling to cryogenic temperatures. Moisture, especially vapor, degrades film quality rapidly. These materials are stable to high temperatures in either N 2 or O 2 ambients. While total degradation, resulting from Tl depletion, occurs at the same temperatures for both phases, 600 degree sign C in N 2 and 700 degree sign C in O 2 , the onset of degradation occurs at somewhat lower temperatures for TlBa 2 CaCu 2 O 7 than for Tl 2 Ba 2 CaCu 2 O 8 . (c) 1999 Materials Research Society

  9. Electronic Structure of TlBa2CaCu2O(7-Delta)

    Science.gov (United States)

    Vasquez, R. P.; Novikov, D. L.; Freeman, A. J.; Siegal, M. P.

    1997-01-01

    The core levels of TlBa2CaCu2O(7-delta) (Tl-1212) epitaxial films have been measured with X-ray photoelectron spectroscopy (XPS). The valence electronic structure has been determined using the full-potential linear muffin-tin-orbital band-structure method and measured with XPS. The calculations show that a van Hove singularity (VHS) lies above the Fermi level (E(sub F)) for the stoichiometric compound (delta = 0.5), while for 50% oxygen vacancies in the Tl-O layer (delta = 0.5) E(sub F) is in close proximity to the VHS. Samples annealed in nitrogen (to reduce the hole overdoping by the removal of oxygen) exhibit higher core-level binding energies and a higher T(sub c), consistent with a shift of E(sub F) closer to the VHS. Comparisons are made to the core levels and valence bands of Tl2Ba2CaCu2O(8 + delta)(Tl-2212) and HgBa2CaCu2O)6 + delta) (Hg- 1212). The similarity of the Cu 2p(sub 3/2) spectra for Tl-1212 and Tl-2212 indicates that the number of Tl-O layers has little effect on the Cu-O bonding. However, the Tl-1212 and Hg-1212 Cu 2p(sub 3/2) signals exhibit differences which suggest that the replacement of T(sup 3+) with Hg(sup 2+) results in a decrease in the O 2p right arrow Cu 3d charge-transfer energy and differences in the probabilities of planar vs apical oxygen charge transfer and/or Zhang-Rice singlet-state formation. Differences between the Tl-1212 and the Tl-2212 and Hg-1212 measured valence bands are consistent with the calculated Cu 3d and (Tl,Hg) 6s/5d partial densities of states.

  10. TL1A regulates TCRγδ+ intraepithelial lymphocytes and gut microbial composition

    DEFF Research Database (Denmark)

    Tougaard, Peter; Skov, S.; Pedersen, A. E.

    2015-01-01

    TL1A is a proinflammatory cytokine, which is prevalent in the gut. High TL1A concentrations are present in patients with inflammatory bowel disease (IBD) and in IBD mouse models. However, the role of TL1A during steady‐state conditions is relatively unknown. Here, we used TL1A knockout (KO) mice ...

  11. Photon and neutron energy response of Thermoluminescent (TL) dosimeters

    International Nuclear Information System (INIS)

    Thilagam, L.; Priya, M.R.; Mohapatra, D.K.

    2018-01-01

    Theoretical Monte Carlo (MC) simulations are carried out to investigate the relative thermoluminesence (TL) response of the most commonly used TLD materials to a wide range of photon energy. The effect of polytetrafluoroethylene (PTFE) on TL response of CaSO 4 :Dy is also studied. Additionally, the neutron response of LiF:Mg,Ti TL materials with different concentrations of 6 Li is estimated in terms of the number of 6 Li(n, t) 4 He capture reactions for a wider neutron energy

  12. Magnetism and superconductivity of some Tl-Cu oxides

    Science.gov (United States)

    Datta, Timir

    1991-01-01

    Many copper oxide based Thallium compounds are now known. In comparison to the Bi-compounds, the Tl-system shows a richer diversity; i.e., High Temperature Superconductors (HTSC) can be obtained with either one or two Tl-0 layers (m = 1,2); also, the triple-digit phases are easier to synthesize. The value of d, oxygen stoichiometry, is critical to achieving superconductivity. The Tl system is robust to oxygen loss; Tl may be lost or incorporated by diffusion. A diffusion coefficient equal to 10 ms at 900 C was determined. Both ortho-rhombic and tetragonal structures are found, but HTSC behavior is indifferent to the crystal symmetry. This system has the highest T(sub c) confirmed. T(sub c) generally increases with p, the number of CuO layers, but tends to saturate at p = 3. Zero resistance was observed at temperatures as great as 125 K. Most of these HTSC's are hole type, but the Ce-doped specimens may be electronic. The magnetic aspects were studied; because in addition to defining the perfectly diamagnetic ground state as in conventional superconductors, magnetism of the copper oxides show a surprising variety. This is true of both the normal and the superconducting states. Also, due to the large phonon contribution to the specific heat at the high T(sub c) jump, electronic density of states, D(Ef), and coherence length are uncertain, and thus, are estimated from the magnetic results. Results from the Tl-system CuO, LaBaCuO,120 and the Bi-CuO compounds are discussed. The emphasis is on the role of magnetism in the Tl-CuO HTSC, but technological aspects are also pointed out.

  13. Thermoluminescence of contaminating minerals for the detection of radiation treatment of dried fruits

    Energy Technology Data Exchange (ETDEWEB)

    Khan, H M; Bhatti, Ijaz A; Delincee, Henry

    2002-03-01

    Several types of dry fruits (pistachio nut, dried apricot, almond and raisins) have been investigated for detection of their radiation treatment by gamma rays or electron beam using thermoluminescence (TL) measurements. These samples were irradiated to 1.0-3.0 kGy (gamma rays) or 0.75-3.9 kGy (10 MeV electron beam). Thermoluminescence glow curves for the contaminating minerals separated from the dry fruits were recorded between the temperature range of 50 deg. C and 500 deg. C. In all the cases, the intensity of TL signal for the irradiated dry fruits was 1-3 orders of magnitudes higher than the TL intensity of the corresponding unirradiated control samples allowing clear distinction between the irradiated and unirradiated samples. These results were normalized by re-irradiating the mineral grains with a gamma-ray dose of 1.0 kGy, and a second glow curve was recorded. The ratio of intensity of the first glow curve (TL{sub 1}) to that after the normalization dose (TL{sub 2}), i.e. (TL{sub 1}/TL{sub 2}) was determined and compared with the recommended threshold values. These parameters, together with comparison of the shape of the first glow curve, gave unequivocal results about the radiation treatment of the dry fruit samples.

  14. Thermoluminescence of contaminating minerals for the detection of radiation treatment of dried fruits

    International Nuclear Information System (INIS)

    Khan, H.M.; Bhatti, Ijaz A.; Delincee, Henry

    2002-01-01

    Several types of dry fruits (pistachio nut, dried apricot, almond and raisins) have been investigated for detection of their radiation treatment by gamma rays or electron beam using thermoluminescence (TL) measurements. These samples were irradiated to 1.0-3.0 kGy (gamma rays) or 0.75-3.9 kGy (10 MeV electron beam). Thermoluminescence glow curves for the contaminating minerals separated from the dry fruits were recorded between the temperature range of 50 deg. C and 500 deg. C. In all the cases, the intensity of TL signal for the irradiated dry fruits was 1-3 orders of magnitudes higher than the TL intensity of the corresponding unirradiated control samples allowing clear distinction between the irradiated and unirradiated samples. These results were normalized by re-irradiating the mineral grains with a gamma-ray dose of 1.0 kGy, and a second glow curve was recorded. The ratio of intensity of the first glow curve (TL 1 ) to that after the normalization dose (TL 2 ), i.e. (TL 1 /TL 2 ) was determined and compared with the recommended threshold values. These parameters, together with comparison of the shape of the first glow curve, gave unequivocal results about the radiation treatment of the dry fruit samples

  15. Two-equivalent electrochemical reduction of a cyano-complex [TlIII(CN)2]+ and the novel di-nuclear compound [(CN)5PtII-TlIII]0

    International Nuclear Information System (INIS)

    Dolidze, Tina D.; Khoshtariya, Dimitri E.; Behm, Martin; Lindbergh, Goeran; Glaser, Julius

    2005-01-01

    Extending our recent insights in two-electron transfer microscopic mechanisms for a Tl III /Tl I redox system [D.E. Khoshtariya, et al., Inorg. Chem. 41 (2002) 1728], the electrochemical response of glassy carbon electrode in acidified solutions of Tl III (ClO 4 ) 3 containing different concentrations of sodium cyanide has been extensively studied for the first time by use of cyclic voltammetry and the CVSIM curve simulation PC program. The complex [Tl III (CN) 2 ] + has been thoroughly identified electrochemically and shown to display a single well-defined reduction wave (which has no anodic counterpart), ascribed to the two-equivalent process yielding [Tl I (aq)] + . This behavior is similar to that of [Tl III (aq)] 3+ ion in the absence of sodium cyanide, disclosed in the previous work, and is compatible with the quasi-simultaneous yet sequential two-electron transfer pattern (with two reduction waves merged in one), implying the rate-determining first electron transfer step (resulting in the formation of a covalently interacting di-thallium complex as a metastable intermediate), and the fast second electron transfer step. Some preliminary studies of the two-equivalent reduction of directly metal-metal bonded stable compound [(CN) 5 Pt II -Tl III ] 0 has been also performed displaying two reduction waves compatible with a true sequential pattern

  16. Left ventricular ejection fraction determined by gated Tl-201 perfusion SPECT and quantitative software

    International Nuclear Information System (INIS)

    Hyun, In Young; Kim, Sung Eun; Seo, Jeong Kee; Hong, Eui Soo; Kwan, Jun; Park, Keum Soo; Lee, Woo Hyung

    2000-01-01

    We compared estimates of ejection fraction (EF) determined by gated Tl-201 perfusion SPECT (g-Tl-SPECT) with those by gated blood pool (GBP) scan. Eighteen subjects underwent g-Tl-SPECT and GBP scan. After reconstruction of g-Tl-SPECT, we measured EF with Cedars software. The comparison of the EF with g-Tl-SPECT and GBP scan was assessed by correlation analysis and Bland Altman plot. The estimates of EF were significantly different (p<0.05) with g-Tl-SPECT (40%±14%) and GBP scan (43%±14%). There was an excellent correlation of EF between g-Tl-SPECT and GBP scan (r=3D0.94, p<0.001). The mean difference of EF between GBP scan and g-Tl-SPECT was +3.2%. Ninety-five percent limits of agreement were ±9.8%. EF between g-Tl-SPECT and GBP scan were in poor agreement. The estimates of EF by g-Tl-SPECT was well correlated with those by GBP scan. However, EF of g-Tl-SPECT doesn't agree with EF of GBP scan. EF of g-Tl-SPECT can't be used interchangeably with EF of GBP scan.=20

  17. Tl and OSL on diopside crystal

    International Nuclear Information System (INIS)

    Cano, N.F.; Watanabe, S.; Mittani, J.C.R.; Yukihara, E.G.

    2006-01-01

    The diopside with chemical composition CaMgSi 2 O 6 is part of an important solid solution series of the pyroxene group. The mineral is commonly found in meteorites and it is an important rock forming mineral of medium and high grade metamorphic rocks which are rich in calcium. In the bibliography it is possible to found several studies on electron spin resonance (ESR), reflectance, etc. but not on thermoluminescence (TL) or optically stimulated luminescence (OSL). In the present work we studied diopside TL and OSL behaviour on natural and natural irradiated samples. The sample used in our study is a white coloured diopside provided by Mineracao Sao Judas located in Sao Paulo, Brazil. The X-Ray Fluorescence technique has shown high concentrations of SiO 2 (55.81 % mol), CaO (23.47 % mol), MgO (18.03 % mol), Al 2 O 3 (1.56 % mol), Fe 2 O 3 (0.53 % mol), K 2 O (0.44 % mol), TiO 2 (0.065 % mol), P 2 O 5 (0.026 % mol), and MnO (0.013 % mol). TL measurements on natural samples show four TL peaks at 160, 260, 360, and 450 C. After beta-irradiation an increment mainly in the low temperature peaks is observed. As for OSL measurements, low OSL signal was observed on natural samples using blue light stimulation and UV detection. The intensity of the signal was observed to increase with the irradiation dose. (Author)

  18. Auto-regenerative TL dating with zircon inclusions from fired materials

    International Nuclear Information System (INIS)

    Templer, R.H.; Smith, B.W.

    1988-01-01

    In this paper it is shown that it is possible to date fired material using zircon inclusions. The effects of zoning and anomalous fading are overcome using an auto-regenerative dating procedure. The high radioactivity of the grains gives a measurable self-induced TL (thermoluminescence) signal within a few months. Comparison of this ''auto-regenerated'' TL with the natural TL (which has accumulated since the firing) yields the age of the material. A sensitive TL reader capable of recording the auto-regenerated signal after 6 months is also described, and the results of age determinations on a number of known age samples are presented. (author)

  19. Thermoluminescence characterization of CVD diamond film exposed to UV and beta radiation

    International Nuclear Information System (INIS)

    Barboza-Flores, M.; Melendrez, R.; Gastelum, S.; Chernov, V.; Bernal, R.; Cruz-Vazquez, C.; Brown, F.; Pedroza-Montero, M.; Gan, B.; Ahn, J.; Zhang, Q.; Yoon, S.F.

    2003-01-01

    Thermoluminescence (TL) properties of diamond films grown by microwave and hot filament CVD techniques were studied. The main purpose of the present work was to characterize the thermoluminescence response of diamond films to ultraviolet and beta radiation. The thermoluminescence excitation spectrum exhibits maximum TL efficiency around 210-215 nm. All samples presented a glow curve composed of at least one TL peak and showed regions of linear as well as supralinear behavior as a function or irradiation dose. The linear dose dependence was found for up to sixteen minutes of monochromatic UV irradiation and 300 Gy for beta irradiated samples. The activation energy and the frequency factor were determined and found in the range of 0.33-1.7 eV and 5.44 x 10 2 -5.67 x 10 16 s -1 , respectively. The observed TL performance is reasonable appropriate to justify further investigation of diamond films as radiation dosimeters keeping in mind that diamond is an ideal TL dosemeter since it is tissue-equivalent and biological compatible. (copyright 2003 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  20. Progress and problems with automated TL dating

    International Nuclear Information System (INIS)

    McKerrell, H.; Mejdahl, V.

    1981-01-01

    A number of basic problems connected with the measurement of beta and gamma dose-rates are discussed, and the possibility of using low-temperature peaks in quartz and feldspar for dose-rate measurements is examined. Preliminary results of TL measurements on individual grains of quartz and feldspar are presented. A TL dating method based on the difference in the archaeological dose received by potassium feldspar and quartz grains is proposed. (author)

  1. Gamma radiation effects in coriander (coriandrum sativum L) for consumption in Mexico

    International Nuclear Information System (INIS)

    Cruz Z, E.; Ruiz G, B.; Flores E, T.; Barboza F, M.

    2011-01-01

    Ionizing radiation is an effective process for disinfecting and prolonging the shelf-life of several food products. Food irradiation may be one of the most significant contributions to public health in the developing countries. Following the irradiation it is necessary to analyze the radiation dose effects in foodstuffs. Thermally stimulated luminescence (Tl) properties and microbiological load as a function of the gamma doses were analyzed in fresh commercial Coriander (Coriandrum sativum L.) samples. For Tl analyses the poly mineral fraction was separated from a coriander and 10 μm size particles were selected. The poly mineral samples were exposed to a 0.5-15,000 Gy dose from gamma radiation using a 60 Co facility, Gamma beam 651PT, semi-industrial irradiator with 98.4 Gy/min dose rate. The glow curves were broad bands and characteristic of quartz that is present in the sample as detected by XRD. The main Tl characteristics were determined, including the structure of the glow curves, Tl response, reproducibility of Tl signals over 12 cycles of subsequent irradiations, and the fading effect during the storage during 30 days. The Tl method was found useful for detection of irradiated coriander. In order to analyze the effect of gamma radiation on the bacterial load in the fresh food coriander, several coriander samples were exposed to 0-10 kGy dose. It was observed that at 0.5 kGy dose the aerobic mesophilic count was reduced to 99.9%, while the initial total coliform bacteria decreased from 871,000 cfu/g to less than 100. The microbiological results are lower than the limit indicated by the Mexican regulatory authority; 150,000 cfu/g for mesophiles and 100 cfu/g for total coliforms. The aim of this work is to investigate the Tl properties of the poly mineral fraction obtained from coriander and to measure the microbiological load as a function of the gamma irradiation dose also. (Author)

  2. Gamma radiation effects in coriander (coriandrum sativum L) for consumption in Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Cruz Z, E. [UNAM, Instituto de Ciencias Nucleares, Unidad de Irradiacion y Seguridad Radiologica, Apdo. Postal 70-543, 04510 Mexico D. F. (Mexico); Ruiz G, B. [Universidad de Sonora, Departmento de Agricultura y Ganaderia, Apdo. Postal 305, 83190 Hermosillo, Sonora (Mexico); Flores E, T. [UNAM, Facultad de Quimica, Departamento de Alimentos y Biotecnologia, Ciudad Universitaria, 04510 Mexico D. F. (Mexico); Barboza F, M. [Universidad de Sonora, Centro de Investigacion en Fisica, Apdo. Postal 5-088, 83190 Hermosillo, Sonora (Mexico)

    2011-02-15

    Ionizing radiation is an effective process for disinfecting and prolonging the shelf-life of several food products. Food irradiation may be one of the most significant contributions to public health in the developing countries. Following the irradiation it is necessary to analyze the radiation dose effects in foodstuffs. Thermally stimulated luminescence (Tl) properties and microbiological load as a function of the gamma doses were analyzed in fresh commercial Coriander (Coriandrum sativum L.) samples. For Tl analyses the poly mineral fraction was separated from a coriander and 10 {mu}m size particles were selected. The poly mineral samples were exposed to a 0.5-15,000 Gy dose from gamma radiation using a {sup 60}Co facility, Gamma beam 651PT, semi-industrial irradiator with 98.4 Gy/min dose rate. The glow curves were broad bands and characteristic of quartz that is present in the sample as detected by XRD. The main Tl characteristics were determined, including the structure of the glow curves, Tl response, reproducibility of Tl signals over 12 cycles of subsequent irradiations, and the fading effect during the storage during 30 days. The Tl method was found useful for detection of irradiated coriander. In order to analyze the effect of gamma radiation on the bacterial load in the fresh food coriander, several coriander samples were exposed to 0-10 kGy dose. It was observed that at 0.5 kGy dose the aerobic mesophilic count was reduced to 99.9%, while the initial total coliform bacteria decreased from 871,000 cfu/g to less than 100. The microbiological results are lower than the limit indicated by the Mexican regulatory authority; 150,000 cfu/g for mesophiles and 100 cfu/g for total coliforms. The aim of this work is to investigate the Tl properties of the poly mineral fraction obtained from coriander and to measure the microbiological load as a function of the gamma irradiation dose also. (Author)

  3. The Tl{sub 2}S–PbS–SiS{sub 2} system and the crystal and electronic structure of quaternary chalcogenide Tl{sub 2}PbSiS{sub 4}

    Energy Technology Data Exchange (ETDEWEB)

    Mozolyuk, M.Y.; Piskach, L.V. [Department of Inorganic and Physical Chemistry, Lesya Ukrainka Eastern European National University, 13 Voli Avenue, 43025, Lutsk (Ukraine); Fedorchuk, A.O. [Department of Inorganic and Organic Chemistry, Lviv National University of Veterinary Medicine and Biotechnologies, 50 Pekarska Street, 79010, Lviv (Ukraine); Olekseyuk, I.D.; Parasyuk, O.V. [Department of Inorganic and Physical Chemistry, Lesya Ukrainka Eastern European National University, 13 Voli Avenue, 43025, Lutsk (Ukraine); Khyzhun, O.Y., E-mail: khyzhun@ipms.kiev.ua [Frantsevych Institute for Problems of Materials Science, National Academy of Sciences of Ukraine, 3 Krzhyzhanivsky Street, 03142, Kyiv (Ukraine)

    2017-07-01

    Chalcogenides of the quasi-ternary system Tl{sub 2}S–PbS–SiS{sub 2} were synthesized in the evacuated silica ampoules by the melting and annealing technique. Phase equilibria in the system was investigated by XRD method. Isothermal section of the system was studied, and two intermediate quaternary phases were discovered to exist (Tl{sub 2}PbSiS{sub 4}, ∼Tl{sub 2}PbSi{sub 3}S{sub 8}). The quasi-binary section Tl{sub 2}SiS{sub 3}–PbS was investigated by DTA. Its phase diagram was constructed, and it was established that the equimolar compound melts incongruently at 818 K. The crystal structure of the quaternary compound Tl{sub 2}PbSiS{sub 4} was determined by X-ray powder diffraction. It crystallizes in the monoclinic space group P2{sub 1}/a with the unit-cell parameters a = 8.8141(4), b = 9.0150(5), c = 10.4383(5) Å, and β = 94.490(4)° (Tl{sub 2}PbGeS{sub 4} structure type). Reliability factors calculated in the isotropic approximation were found to be R{sub I} = 0.0564 and R{sub P} = 0.1070. The Tl{sub 2}PbSiS{sub 4} single crystal was tested with X-ray photoelectron spectroscopy. In particular, the XPS core-level and valence-band spectra were recorded for pristine and Ar{sup +}-ion bombarded surfaces of Tl{sub 2}PbSiS{sub 4}. The Tl{sub 2}PbSiS{sub 4} single crystal was found to be rather stable with respect to Ar{sup +}-ion irradiation. We have also measured the X-ray emission band depicting the energy distribution of mainly the S 3p states and compared it on a common energy scale with the XPS valence-band spectrum of the Tl{sub 2}PbSiS{sub 4} crystal. The above comparison indicates that the S 3p states contribute substantively in the upper portion of the valence band of Tl{sub 2}PbSiS{sub 4}, with their significant contributions in other portions of the valence-band region. - Highlights: • Chalcogenides of the quasi-ternary system Tl{sub 2}S–PbS–SiS{sub 2} were synthesized. • Two intermediate quaternary phases were discovered to exist (Tl

  4. Contributions to a systematic examination of deformed transition nuclei by the study of the decay of 188Tl and 190Tl

    International Nuclear Information System (INIS)

    Waetzig, W.

    1980-01-01

    Using the reaction 197 Au( 3 He,xn) Tl the decay of the nuclides 188 Tl and 190 Tl to 188 Hg (Tsub(1/2) = 70s) respectively to 190 Hg(Tsub(1/2) = 3.0 min) was studied at the mass separator ISOCELE of the Orsay-synchrocyclotron by gamma, conversion electron, gamma-gamma coincidence, and electron-gamma coincidence spectroscopy. The level schemes of 188 Hg and 190 Hg could be remarkably extended in comparison with earlier works. By a statistical analysis of the nuclear level density the nuclear temperature was calculated as a measure for the number of excitation modes of these nuclei. (orig./HSI) [de

  5. Proposal of a dosemeter for skin beta radiation dose assessment

    International Nuclear Information System (INIS)

    Rosa, L.A.R. da; Caldas, L.V.E.

    1987-08-01

    Beta radiation is, undoubtedly, less penetrating than X or gamma radiation. Thus, beta radiation sources external to the human body do not cause a significant irradiation of its deeper tissues. However, in some cases, they may contribute in a very important way to the irradiation of the lens of the eyes and, mainly, of the skin. Specially, the hands and finger tips may receive a high dose. In this work some relevant aspects of the individual monitoring in beta radiation fields are discussed and the importance of monitoring this kind of radiation in some activities where the skin absorbed dose may be a limiting factor is evidenced. The main characteristics of the thermoluminescent (TL) response of ultra-thin CaSO 4 : Dy detectors (UT-CaSO 4 : Dy) in the detection of this kind of radiation are also studied. The irradiation are performed with 90 Sr 90 Y, 204 TI and 147 Pm sources. The reproducibility, linearity, dependence on the absorbed dose rate, optical fading, energy and angular dependences of the detector TL responce are investigated. Transmission factors for different thicknesses of tissue equivalent material are obtained for the TL detectors using the three available beta sources. Based on the results obtained, a dosemeter for skin beta radiation absorbed dose assessment with an energy dependence better than 12% is proposed. (Author) [pt

  6. Leg 201Tl-SPECT in chronic exertional compartment syndrome

    International Nuclear Information System (INIS)

    Elkadri, N.; Slim, I.; Blondet, C.; Choquet, Ph.; Constantinesco, A.; Lecocq, J.

    2004-01-01

    Leg 201 Tl-SPECT in chronic exertional compartment syndrome Background: The chronic exertional compartment syndrome is one of the most frequent origins regarding leg pain due to sport training. The diagnosis can be established by invasive compartment pressure measurement. The aim of this study is to evaluate the role that could have 201 Tl-SPECT for patients with suspicion of compartment syndrome. Patients and methods: 51 leg 201 Tl-SPECT exams were performed (exercise - and rest without reinjection) in 49 patients; 28 had compartment syndrome confirmed by pressure measurement. About 100 MBq of 201 Tl were injected during exercise, when pain appeared or at least after 25 minutes exercise. We studied mean percentages of level uptake for each compartment, referred to the maximal uptake of both legs. Results: 47 compartments were concerned by compartment syndrome and 361 compartments were not. Scintigraphic patterns in compartments are reversible ischaemia (45%), uptake stability (36%) or reverse redistribution (19%); these patterns are not linked to compartment syndrome. However, there is a significant difference of rest 201 Tl level uptake between compartments with and without compartment syndrome and a significant correlation between muscular pressure measurement and rest level uptake. Conclusion: 201 Tl-SPECT shows that only ischaemia does not explain compartment syndrome. Moreover, it allows to predict pressure variation during exercise but it does not offer any interest in order to select patients for muscular invasive pressure measurement. (author)

  7. Accidental and retrospective dosimetry using TL method

    International Nuclear Information System (INIS)

    Mesterházy, D.; Osvay, M.; Kovács, A.; Kelemen, A.

    2012-01-01

    Retrospective dosimetry is one of the most important tools of accidental dosimetry for dose estimation when dose measurement was not planned. In the affected area many objects can be applied as natural dosimeters. The paper discusses our recent investigations on various electronic components and common salt (NaCl) having useful thermoluminescence (TL) properties. Among materials investigated the electronic components of cell phones seem promising for retrospective dosimetry purposes, having high TL responses, proper glow curve peaks and the intensity of TL peaks vs. gamma dose received provided nearly linear response in the dose range of 10 mGy–1.5 Gy. - Highlights: ► Electronic components and common salt were investigated for accidental and retrospective dosimetry. ► SMD resistors seem promising for retrospective dosimetry purposes. ► Table salt can be used effectively for accidental dosimetry purposes, as well.

  8. Stability of Tl-Ba-Ca-Cu-O superconducting thin films

    Energy Technology Data Exchange (ETDEWEB)

    Siegal, M. P. [Sandia National Laboratories, Albuquerque, New Mexico 87185-1421 (United States); Overmyer, D. L. [Sandia National Laboratories, Albuquerque, New Mexico 87185-1421 (United States); Venturini, E. L. [Sandia National Laboratories, Albuquerque, New Mexico 87185-1421 (United States); Padilla, R. R. [Sandia National Laboratories, Albuquerque, New Mexico 87185-1421 (United States); Provencio, P. N. [Sandia National Laboratories, Albuquerque, New Mexico 87185-1421 (United States)

    1999-12-01

    We report the stability of TlBa{sub 2}CaCu{sub 2}O{sub 7} and Tl{sub 2}Ba{sub 2}CaCu{sub 2}O{sub 8} on LaAlO{sub 3}(100) epitaxial thin films, under a variety of conditions. All films are stable in acetone and methanol and with repeated thermal cycling to cryogenic temperatures. Moisture, especially vapor, degrades film quality rapidly. These materials are stable to high temperatures in either N{sub 2} or O{sub 2} ambients. While total degradation, resulting from Tl depletion, occurs at the same temperatures for both phases, 600 degree sign C in N{sub 2} and 700 degree sign C in O{sub 2}, the onset of degradation occurs at somewhat lower temperatures for TlBa{sub 2}CaCu{sub 2}O{sub 7} than for Tl{sub 2}Ba{sub 2}CaCu{sub 2}O{sub 8}. (c) 1999 Materials Research Society.

  9. High current Tl-203, Rh-103 targets preparation for cyclotron production of Tl-201 and Pd-103 radionuclides

    International Nuclear Information System (INIS)

    Arzumanov, A.; Berger, V.; Borissenko, A.; Gorodisskaya, N.; Ilmatov, I.; Knyazev, A.; Koptev, V.; Lyssukhin, S.; Platov, A.; Sychikov, G.; Zheltov, D.

    2004-01-01

    The objectives of the present work are to increase thermal stability of cyclotron targets for production of Tl-201 isotope, increase Tl-203 regeneration rate at radiochemical reprocessing of the targets and develop production technology for radiochemical sources based on Rd-103 isotope. Electrochemical coating of copper substrate with Tl increased the beam current at target irradiation from 100 μA to 125 μA. Further increase of the beam current results in sharp decrease of target stability time at irradiation to 15 min at beam current 150 μA. Thermal calculations and tests at the electron-beam stand predict satisfactory stability at such currents. The discrepancy with the irradiation results has not been explained. More accurate specification of regimes for Tl-203 electrochemical recovery from irradiated targets and better matching of the electrolyte composition made it possible to increase the recovery rate up to 99.5%. Before the present Project, the INP had no experience in production of radioactive sources based on Pd-103. Thermo-diffusion extraction of Pd-103 from irradiated rhodium foil has been chosen as a technology-defining method. The process assures good extraction rate and high purity of extracted isotope. Production of Pd-103 sources based on this technology is much simpler compared to the same based on electrochemical processes. (author)

  10. Annual dose measurements and TL-dating of ancient Egyptian pottery

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Wahab, M S; El-Fiki, S A; Abdel-Kariem, S; El-Faramawy, N [Ain Shams University, Cairo (Egypt). Faculty of Science; EL-Fiki, M A [National Institute of Standards, Cairo (Egypt); Gomaa, M [Atomic Energy Establishment, Cairo (Egypt). Nuclear Research Center

    1996-05-01

    In the course of the dating of ancient Egyptian pottery, pottery sherds were collected from three archaeological tombs in Nazlet El Samman region, Giza zone (Egypt). The annual dose from natural background was measured by gamma spectrosocopic technique as well as thermoluminescence (TL) measurements. The results of both methods are in good agreement with a consistency of 99.69%. The extracted quartz exhibited TL dating peaks at about (305 {+-} 5){sup o}C. The TL dating shows an age of 4301 {+-} 100 years for the examined pottery which belongs to the ``Fourth Dynasty`` in the ``OlKingdom`` . The uncertainties in TL dating using the additive method are much lower than that of archaeologists. (author).

  11. Annual dose measurements and TL-dating of ancient Egyptian pottery

    Science.gov (United States)

    Abdel-Wahab, M. S.; El-Fiki, S. A.; El-Fiki, M. A.; Gomaa, M.; Abdel-Kariem, S.; El-Faramawy, N.

    1996-05-01

    In the course of the dating of ancient Egyptian pottery, pottery sherds were collected from three archaeological tombs in Nazlet El Samman region, Giza zone (Egypt). The annual dose from natural background was measured by gamma spectroscopic technique as well as thermoluminescence (TL) measurements. The results of both methods are in good agreement with a consistency of 99.69%. The extracted quartz exhibited TL dating peaks at about(305 ± 5|4)°C. The TL dating shows an age of 4301 ± 100 years for the examined pottery which belongs to the "Fourth Dynasty" in the "Old Kingdom". The uncertainties in TL dating using the additive method are much lower than that of archeologists.

  12. Annual dose measurements and TL-dating of ancient Egyptian pottery

    International Nuclear Information System (INIS)

    Abdel-Wahab, M.S.; El-Fiki, S.A.; Abdel-Kariem, S.; El-Faramawy, N.; Gomaa, M.

    1996-01-01

    In the course of the dating of ancient Egyptian pottery, pottery sherds were collected from three archaeological tombs in Nazlet El Samman region, Giza zone (Egypt). The annual dose from natural background was measured by gamma spectrosocopic technique as well as thermoluminescence (TL) measurements. The results of both methods are in good agreement with a consistency of 99.69%. The extracted quartz exhibited TL dating peaks at about (305 ± 5) o C. The TL dating shows an age of 4301 ± 100 years for the examined pottery which belongs to the ''Fourth Dynasty'' in the ''OlKingdom'' . The uncertainties in TL dating using the additive method are much lower than that of archaeologists. (author)

  13. Study of /sup 201/Tl uptake by bone and bone marrow on /sup 201/Tl scintigraphy. With special reference to bone marrow abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Tadashige; Tanaka, Masao; Hirose, Yoshiki; Hirayama, Jiro; Handa, Kenjiro; Nakanishi, Fumiko; Yano, Kesato; Ueda, Hitoshi

    1989-04-01

    Thallium-201 (Tl-201) uptake in the bone and bone marrow was examined in a total of 93 patients with various diseases. Sternal uptake of Tl-201 was observed when patients had bone marrow abnormality especially associated with hematopoietic disease. It was associated with proliferation of immature cells and of various types of bone marrow cells, especially erythroblastic and plasma cells. Whole-body Tl-201 scanning showed a high uptake (82%) in the sternum, chest, lumbar vertebrae, and pelvis. Thallium-201 was definitively taken up by the sternum in polycythemia (5/41), hemolytic anemia (2/2), iron deficiency anemia (2/2), and multiple myeloma (2/5). For leukemia, Tl-201 uptake was slight or negative. Thallium-201 scanning proved useful in visualizing bone marrow abnormality, although careful interpretation of bone and bone marrow uptake is required. (Namekawa, K).

  14. Dosimetric characterization and identification of TL defect centres in sand for its application in sludge irradiators as an in situ dosimeter

    International Nuclear Information System (INIS)

    Benny, P.G.; Shah, M.R.; Sabharwal, S.; Bhatt, B.C.; Gundu Rao, T.K.

    2003-08-01

    The report presents investigations that have been carried out to establish a method for the routine/ periodic dosimetry for Sludge Hygienisation Research Irradiator (SHRI) facility set up at Baroda (India) for disinfection of liquid sewage sludge in bulk quantity. For this purpose, the possibility of using the sand, one of the components of inorganic matter found in sewage sludge, directly as a TL dosimeter has been explored. The report is presented in two parts. Part 1 presents dosimetric characterization of sand for its application as an in situ dosimeter. A review on various sewage sludge irradiators operating in the world and the different dosimetric techniques used for these facilities are briefly described. In the present studies, in order to investigate the thermoluminescence properties of sand, it was separated from the sewage sludge by an extensive cleaning procedure. Part 1 also describes the procedure for separation of sand from sewage sludge, study on its TL properties, dosimetric characterization of sand and application of cleaned sand collected at the outlet of the SHRI facility for estimating radiation absorbed dose imparted to the sludge during its disinfection as well as for determining distribution of dose for an irradiated sludge batch. A new method by using phototransferred thermoluminescence (PTTL) in quartz separated from sand has been explored for high-level gamma dosimetry. Part 2 of the report presents sensitization properties of TL peaks and study of TL defect centres in quartz. It describes the results on pre-dose sensitization of 220 degC and 110 degC TL peaks in the quartz samples separated from sand. From the TL and ESR studies, a mechanism for TL sensitization has been suggested, which involves the role of competing traps and E I - centres in the sensitization process. The paramagnetic radicals formed in quartz samples after gamma irradiation by using ESR technique have been briefly described. (author)

  15. Study of morphological and luminescent properties (TL and OSL) of ZnO nanocrystals synthetized by coprecipitation method

    Energy Technology Data Exchange (ETDEWEB)

    Soares, A.F., E-mail: alvarodefarias@hotmail.com; Tatumi, S.H., E-mail: sonia.tatumi@gmail.com; Mazzo, T.M.; Rocca, R.R.; Courrol, L.C.

    2017-06-15

    In this work, ZnO nanocrystalline phosphorus were synthesized using the method of coprecipitation, subsequently different heat treatments at 900 and 1000 °C for 2 h and 1000 °C for 4 h were performed. Afterward, Thermoluminescence (TL) and Optically Stimulated Luminescence (OSL) emissions were verified after exposure to β-radiation. Photoluminescence results showed UV and VIS emissions. Morphological studies with X-ray diffraction (XRD) and Scanning Electron Microscopy (SEM) confirmed the crystallinity of the samples, with their well-shaped wurtzite hexagonal structures in nanoscale. ZnO calcinated at 900 °C – 2 h emitted a broad TL peak located between the 362–372 °C; for ZnO calcinated at 1000 °C – 2 h, two intense peaks were observed at 144 and 308 °C, this TL emission curve was investigated with more details using Computerized Glow Curve Deconvolution and six individual TL peaks were obtained, for sample irradiated with 40.6 Gy, corroborating with the T{sub m}-T{sub stop} results. A study of Minimum Detectable Dose (MDD) was made and a dose of (492±40) μGy was determined. CW-OSL and LM-OSL analysis were made for ZnO calcinated at 1000 °C – 2 h, allowed to verify the behaviour, and the curve existing components (fast and medium, depending on dose). As well as the calculation of the Minimum Detectable Dose for CW-OSL. - Highlights: •ZnO nanocrystals were successfully produced by the method of coprecipitation. •Grains sizes by Scherrer Equation were between 26.9–40.6 nm, corroborating with SEM. •Study of the TL emission: Computerized Glow Curve Deconvolution (CGCD) and Tm-Tstop. •TL emission of ZnO calcinated supplied the minimum detectable dose of (492±40) μGy. •Study of CW-OSL and LM-OSL with CGCD. MDD for CW-OSL evaluation of ZnO calcinated.

  16. Leading the Charge for SoTL--Embracing Collaboration

    Science.gov (United States)

    Cassard, Anita; Sloboda, Brian

    2014-01-01

    The scholarship of teaching and learning (SoTL) enables colleges and universities to assess student learning and measure the outcomes by engaging in meaningful research, and to disseminate this research. The objective of this paper is to give a snapshot of and assess the current thinking behind this scholarship by presenting examples of SoTL, and…

  17. El papel del sector privado en la respuesta humanitaria

    OpenAIRE

    Narfeldt, Soraya

    2008-01-01

    El objetivo de cualquier empresa es ganar dinero, pero lo que cuenta es cómo se gana ese dinero. Se las debe animar a que vean los muchos beneficios que aportan el apoyo a la respuesta humanitaria y el funcionamiento ético.

  18. Temperature- and excitation intensity-dependent photoluminescence in TlInSeS single crystals

    CERN Document Server

    Gasanly, N M; Yuksek, N S

    2002-01-01

    Photoluminescence (PL) spectra of TlInSeS layered single crystals were investigated in the wavelength region 460-800 nm and in the temperature range 10-65 K. We observed one wide PL band centred at 584 nm (2.122 eV) at T=10 K and an excitation intensity of 7.5 W cm sup - sup 2. We have also studied the variation of the PL intensity versus excitation laser intensity in the range from 0.023 to 7.5 W cm sup - sup 2. The red shift of this band with increasing temperature and blue shift with increasing laser excitation intensity was observed. The PL was found to be due to radiative transitions from the moderately deep donor level located at 0.243 eV below the bottom of the conduction band to the shallow acceptor level at 0.023 eV located above the top of the valence band. The proposed energy-level diagram permits us to interpret the recombination processes in TlInSeS layered single crystals.

  19. Temperature- and excitation intensity-dependent photoluminescence in TlInSeS single crystals

    International Nuclear Information System (INIS)

    Gasanly, N M; Aydinli, A; Yuksek, N S

    2002-01-01

    Photoluminescence (PL) spectra of TlInSeS layered single crystals were investigated in the wavelength region 460-800 nm and in the temperature range 10-65 K. We observed one wide PL band centred at 584 nm (2.122 eV) at T=10 K and an excitation intensity of 7.5 W cm -2 . We have also studied the variation of the PL intensity versus excitation laser intensity in the range from 0.023 to 7.5 W cm -2 . The red shift of this band with increasing temperature and blue shift with increasing laser excitation intensity was observed. The PL was found to be due to radiative transitions from the moderately deep donor level located at 0.243 eV below the bottom of the conduction band to the shallow acceptor level at 0.023 eV located above the top of the valence band. The proposed energy-level diagram permits us to interpret the recombination processes in TlInSeS layered single crystals

  20. Value of 201Tl imaging in predicting therapeutic 131I uptake in patients with thyroglobulin-positive but 131I scan-negative differentiated thyroid carcinoma

    International Nuclear Information System (INIS)

    Conlu, R.A.O.; Obaldo, J.M.

    2004-01-01

    Background: Serum thyroglobulin assay and 131Iodine (1311) whole body scan are considered complementary in detecting malignant thyroid tissue or metastases. A large number of patients, however, are encountered presenting with scan-negative, thyroglobulin-positive differentiated thyroid carcinoma posing a dilemma in therapeutic management. One of the first alternative scanning agents to be employed is 201Thallium (201Tl). Recent studies have demonstrated its usefulness in identifying lesions that are not visualized with traditional 131I whole body scan. It is not clear, however, whether 201Tl scan helps in the decision-making for subsequent 131I therapy. This study was conducted to determine if 201Tl scan can predict therapeutic 131I uptake and to define the clinical role of 201Tl scanning in these patients. Methods and results: A total of 12 patients (20-63 y/o), 5 males and 7 females, underwent surgery for differentiated thyroid cancer and all had serum thyroglobulin values above 10 ng/ml and normal TPO autoantibodies. Pre-therapy 131I scan using 111 MBq (3mCi) of 131I were obtained. As required for inclusion, all patients had negative pre-therapy scan and negative TPO autoantibody results and underwent 20lTl scanning within 3 weeks. All patients were given 131I therapy (3.7-5.5 GBq or 100-150 mCi) between one to two months after 201Tl scanning. Within a week after therapy, all patients underwent whole body 1311 scanning. 201Tl imaging demonstrated thyroid remnants in 9 out of 12 patients having positive 201Tl scan but negative pre-therapy 1311 scan. However, only 2 of the positive 201Tl scans showed 131I uptake post-therapy (positive predictive value of 20%). None of the subjects presented with a negative 201Tl scan and a positive post-therapy 131I scan. Conclusion: Our study suggests that evidence of remnants or metastases on 201Tl scanning may be an inappropriate basis for the decision to proceed with 131I therapy. The role of 20lTl imaging in this subset of

  1. Microcomputer-Controlled Reader Systems for Archaeological and Geological TL Dating

    DEFF Research Database (Denmark)

    Bøtter-Jensen, Lars; Mejdahl, V.

    1984-01-01

    Two fully automated TL reader systems for TL dating and a manually operated reader for research purpose were put into operation during 1982-3. All systems are controlled by HP-85 or HP-86 microcomputers; thus flexibility in selection of measurement parameters, calculation of TL signals and displa...... the archaeological and geological ages. The principle of the measurement procedures are described, and dating results are presented to illustrate the performance of the systems...

  2. Benchmarking NaI(Tl) Electron Energy Resolution Measurements

    International Nuclear Information System (INIS)

    Mengesha, Wondwosen; Valentine, J D.

    2002-01-01

    A technique for validating electron energy resolution results measured using the modified Compton coincidence technique (MCCT) has been developed. This technique relies on comparing measured gamma-ray energy resolution with calculated values that were determined using the measured electron energy resolution results. These gamma-ray energy resolution calculations were based on Monte Carlo photon transport simulations, the measured NaI(Tl) electron response, a simplified cascade sequence, and the measured electron energy resolution results. To demonstrate this technique, MCCT-measured NaI(Tl) electron energy resolution results were used along with measured gamma-ray energy resolution results from the same NaI(Tl) crystal. Agreement to within 5% was observed for all energies considered between the calculated and measured gamma-ray energy resolution results for the NaI(Tl) crystal characterized. The calculated gamma-ray energy resolution results were also compared with previously published gamma-ray energy resolution measurements with good agreement (<10%). In addition to describing the validation technique that was developed in this study and the results, a brief review of the electron energy resolution measurements made using the MCCT is provided. Based on the results of this study, it is believed that the MCCT-measured electron energy resolution results are reliable. Thus, the MCCT and this validation technique can be used in the future to characterize the electron energy resolution of other scintillators and to determine NaI(Tl) intrinsic energy resolution

  3. Technology development for evaluation of operational quantities in radiation protection

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jang Lyul; Chang, S. Y.; Lee, L. T.; Kim, B. H.; Chung, K. K.; Lee, J. I.; Lim, G. S.; Kim, J. S.; Nam, Y. M.; Chang, J. K.; Kim, D. Y.; Yang, J. S

    2000-03-01

    A study on the fabrication of a new personal thermo-luminescence dosimeter, which can evaluate the personal dose equivalent H{sub p}(d), has been performed. Optimum conditions for fabrication of a LiF:Mg,Cu,Na,Si TL phosphor powder has been determined and a disc type TL pellet has been fabricated from this TL powder. Another type of CaSO{sub 4}:Dy,Mo TL material has been also fabricated. These two TL materials have shown greater TL sensitivity than the foreign-made commercial TL materials. Mono-energetic fluorescence X-ray from 8.6 keV to 75 keV for use in performance testing of the developed TLDs energy response have been constructed and evaluated for the performance of the purity, air kerma, beam uniformity and distribution, and scattered fraction of X-rays. Reference neutron field of a D{sub 2}O moderated {sup 252}Cf source was characterized and the irradiation system using {sup 226}Ra and {sup 137}Cs sources was installed to construct the environmental gamma reference radiation and the low-level gamma radiation. A capability of calibration and measurement of KAERI In Vivo counting system for transuranic elements in the lung has been evaluated through the participation in the overseas intercomparison study on the In Vivo radioactivity measurement. An improvement and advancement of KAERI lung counting technology have been made by the analysis off uncertainties from the assumption of uniform radioactivity distribution in the lung, experimental determination and comparing of detection efficiency with different lung sets, and mathematical efficiency calibration of In Vivo counting system. (author)

  4. Effects of ischemic-like insult on myocardial 201Tl accumulation

    International Nuclear Information System (INIS)

    Goldhaber, S.Z.; Newell, J.B.; Alpert, N.M.; Andrews, E.; Pohost, G.M.; Ingwall, J.S.

    1983-01-01

    Despite extensive clinical use of thallium-201 ( 201 Tl) for myocardial imaging, the effect of ischemia on myocardial accumulation and release of 201 Tl independent of flow has not been fully defined. Therefore, myocardial accumulation of 201 Tl in response to ischemic-like myocardial injury was assessed in vitro using the cultured fetal mouse heart preparation. Cultured fetal mouse hearts (n . 311) were subjected to injury simulating ischemia by deprivation of oxygen and oxidizable substrates for periods ranging from 15 minutes to 10 hours. The extent of irreversible injury was determined by the percentage of lactic dehydrogenase (LDH) lost from the hearts to the culture medium during recovery from injury. Injury was essentially reversible at 1 hour of insult. The fraction of 201 Tl content in injured compared with control hearts was not significantly lower after 1 hour of insult. By 3 hours of insult, irreversible injury as assessed by loss of LDH was detectable and the extent of injury increased progressively through 10 hours. During the 3-10-hour period of irreversible injury, 201 Tl accumulation within injured hearts compared with controls was related in a monotonically decreasing fashion to the loss of LDH as described by a mathematical kinetic model that fit the observations closely (R2 greater than 0.99). These results indicate that in this organ culture preparation, in which there is effectively an unlimited reservoir of 201 Tl and no confounding effects of perfusion, the time-dependent 201 Tl accumulation is determined by the extent of irreversible injury

  5. Respuestas psicofisiológicas ante estímulos asociados al tabaco: Diferencias entre fumadores y no fumadores

    Directory of Open Access Journals (Sweden)

    Carlos Gantiva

    2016-09-01

    Full Text Available Las respuestas emocionales y motivacionales son fundamentales para explicar el inicio y mantenimiento del consumo de tabaco; sin embargo, las diferencias en fumadores y no fumadores de las respuestas psicofisiológicas que sirven como marcadores neurofisiológicos de procesos emocionales y motivacionales presentan resultados contradictorios. El objetivo de esta investigación fue identificar las diferencias en las respuestas psicofisiológicas ante estímulos asociados al tabaco en fumadores y no fumadores. Para esto se registró el reflejo de sobresalto y la respuesta galvánica de la piel mientras observaban imágenes apetitivas, neutrales, aversivas y asociadas al tabaco. Los resultados muestran que los fumadores inhiben el reflejo de sobresalto ante las imágenes asociadas al tabaco de forma similar que ante las imágenes apetitivas; así mismo, se encontró en los fumadores una mayor inhibición del reflejo de sobresalto ante las imágenes de tabaco. No se encontraron diferencias en la respuesta galvánica de la piel. Estos resultados sugieren que los fumadores activan el sistema motivacional apetitivo ante los estímulos asociados al tabaco.

  6. Systems Tl2MoO4-E(MoO4)2, where E=Zr or Hf, and the crystal structure of Tl8Hf(MoO4)6

    International Nuclear Information System (INIS)

    Bazarov, B.G.; Bazarova, Ts.T.; Fedorov, K.N.; Bazarova, Zh.G.; Chimitova, O.D.; Klevtsova, R.F.; Glinskaya, L.A.

    2006-01-01

    Systems Tl 2 MoO 4 -E(MoO 4 ) 2 (E=Zr, Hf) were studied by X-ray diffraction, differential thermal analysis and IR spectroscopy. Formation of Tl 8 E(MoO 4 ) 6 and Tl 2 E(MoO 4 ) 2 compounds was established. Phase T-x diagrams of the Tl 2 MoO 4 -Zr(MoO 4 ) 2 system were constructed. Monocrystals were grown, and structure of Tl 8 Hf(MoO 4 ) 6 was studied. The compound is crystallized in monoclinic syngony with elementary cell parameters a=9.9688(6), b=18.830(1), c=7.8488(5) A, β=108.538(1) Deg, Z=2, sp. gr. C2/m. The isolated group [HfMo 6 O 24 ] 8- is responsible for fundamental fragment of the structure. Three varieties of crystallographically independent Tl-polyhedra fill space evenly between fragments [HfMo 6 O 24 ] 8- forming three-dimensional form [ru

  7. A preliminary study of landslide gouge dating by TL technique

    Energy Technology Data Exchange (ETDEWEB)

    Fengju, Ji; Jianping, Li [Inst. of Geology, National Seismological Bereau, Beijing (China); Mingda, Liu [Inst. of Crustal Dynamics, SSB, Beijing (China)

    1993-04-01

    The key to date slipping of landslide by TL method is whether the temperature and pressure caused by slipping can lead the original TL to 'zero'for some minerals within the slipping band. For this purpose, the simulated experiments under different temperature-pressure were made and the TL annealing effect of landslide gouge was studied. The results show that the frictional heating caused during slipping is a main factor leading the mineral's TL to decrease on the slip plane and that increment of temperature is in close relation with strength of shear stress, thickness of landslide gouge and amount of displacement. As an example, the slipping age of a paleo-landslide at Huangtupo, Hubei Province, has been dated to be about 140 ka.

  8. Radiation dosimeters for medical use

    International Nuclear Information System (INIS)

    Risticj, S. Goran

    2013-01-01

    The several personal radiation dosimeter types for medical use, which look like promising for this kind of application, as pMOS (RADFET) dosimeter, direct ion storage (DIS) dosimeters, thermoluminescent (TL) and optically stimulated luminescent (OSL) dosimeters, are described, and their advantages and disadvantages are analyzed. The p-channel metal-oxide-semiconductor (pMOS) dosimetric transistors allow dose measurements in vivo in real time, and they are especially important for radiotherapy. Direct ion storage (DIS) dosimeters are a hybrid of ion chamber and floating gate MOSFETs (FGMOSFETs), show very high sensitivity. Radiative processes that happen during the exposure of crystal to radiation are classified as prompt luminescence or radioluminescence (RL). In the case of an emission during stimulation, this phenomenon is referred to thermoluminescence or optically stimulated luminescence depending on whether the stimulation source is heat or light. TL and OSL dosimeters are natural or synthetic materials, which the intensity of emitted light is proportional to the irradiation dose. (Author)

  9. Dielectric and baric characteristics of TlS single crystal

    Energy Technology Data Exchange (ETDEWEB)

    Mustafaeva, S.N., E-mail: solmust@gmail.com [Institute of Physics, ANAS, G. Javid prosp. 33, Az 1143 Baku (Azerbaijan); Asadov, M.M. [Institute of Chemical Problems, ANAS, G. Javid prosp. 29, Az 1143 Baku (Azerbaijan); Ismailov, A.A. [Institute of Physics, ANAS, G. Javid prosp. 33, Az 1143 Baku (Azerbaijan)

    2014-11-15

    The investigation of the frequency dependences of the dielectric coefficients and ac-conductivity of the TlS single crystals made it possible to elucidate the nature of dielectric loss and the charge transfer mechanism. Moreover, we evaluated the density and energy spread of localized states near the Fermi level, the average hopping time and the average hopping length. It was shown that the dc-conductivity of the TlS single crystals can be controlled by varying the hydrostatic pressure. This has opened up possibilities for using TlS single crystals as active elements of pressure detectors.

  10. Phase equilibria in TlX-Cd(Zn)X (X-S, Se, Te) systems

    International Nuclear Information System (INIS)

    Gusejnov, F.Kh.; Babanly, M.B.; Kuliev, A.A.

    1982-01-01

    The methods of DTA, RPA and measurement of the alloys microhardness have been used to investigate the phase equilibria in the TlX-Zn(Cd)X systems. It is established that the TlZn(Cd)X 2 compounds, the presence of which is mentioned in the literature earlier, do not form in these systems. The TlSe-Zn(Cd)Se systems apply to the simple eutectic type and characterized by digenerated eutectic near the TlSe. Thermodynamical analysis of the liquidus of the TlSe-CdSe and TlTe-Zn(Cd)Te systems in approximation of the regular solutions, taking into account the dissociation of tallium chalcogenides in liquid phase, is made

  11. TL process in europium doped alkaline earth sulphate phosphors- a review

    International Nuclear Information System (INIS)

    Bhatt, B.C.

    2003-01-01

    CaSO 4 doped with the rare earth (RE) ion dysprosium or thulium is used routinely as a thermoluminescent dosimeter (TLD) to monitor personal exposure to x- and γ-radiation. The CaSO 4 :Eu phosphor is potentially important for radio photoluminescence (RPL) and ultraviolet (UV) dosimetry. Eu 3+ → Eu 2+ conversion is suggested to play a pivotal role in UV and γ-ray induced thermoluminescence. However, there is disagreement among different workers on the mechanism of gamma and UV induced TL in this phosphor system. This paper will review the work reported on CaSO 4 :Eu and make effects to project overall picture on this phosphor system. (author)

  12. TL Dosimetry on the Tandetron Ion Accelerator area of the ININ

    International Nuclear Information System (INIS)

    Valdovinos A, M.A.; Gonzalez M, P.R.

    2000-01-01

    For the fulfilment of the operation tests of the Positive Ions type Tandetron 4120 MC, 2 MV, it was obtained the permission consented by the National Commission of Nuclear safety and safeguards (CNSNS). During the stage of tests were arranged Tl dosemeters in the Tandetron Accelerator area, as well as toward to the beam exit. In this work, it was presented the results obtained of the measurement of radiation levels, as much in the area as in the beam exit. This Accelerator is useful in different fields of science such as: biology, radiochemistry, materials, solid state physics, archaeology and environmental sciences between others. (Author)

  13. Expanding the Teaching Commons: Making the Case for a New Perspective on SoTL

    Directory of Open Access Journals (Sweden)

    Kim A. Case, PhD

    2013-08-01

    Full Text Available As a reflection on O’Meara, Terosky, and Neumann’s (2011 work on scholarship of teaching and learning (SoTL faculty development, this essay describes the benefits of SoTL to individual faculty and university goals. In support and expansion of arguments advanced by O’Meara et al., this work calls for the use of SoTL faculty development to promote the shared teaching commons, active recruitment of new SoTL scholars, institutionalization of SoTL values, and integration of SoTL initiatives in both teaching centers and research-focused development offices.

  14. First-principles prediction of Tl/SiC for valleytronics

    KAUST Repository

    Xu, Zhen; Zhang, Qingyun; Shen, Qian; Cheng, Yingchun; Schwingenschlö gl, Udo; Huang, Wei

    2017-01-01

    Recently, monolayer Tl on a Si or Ge substrate has been proposed for potential valleytronic systems. However, the band gaps of these systems are less than 0.1 eV, which is too small to be applied because an electric field or magnetic doping will reduce the band gaps further for the systems to become metallic. Here, we investigate SiC as an alternative substrate. By first-principles calculations we demonstrate that monolayer Tl can be grown on SiC. There are two valleys around the K/K′ points and the Berry curvature shows that the two valleys are inequivalent, indicating valley pseudospin. Moreover, due to the larger band gap of SiC (3.3 eV), the band gap of the Tl/SiC system is 0.6 eV, which is large enough for valley manipulation. Furthermore, we demonstrate that Cr doping can achieve valley polarization. Our study shows that the Tl/SiC system is promising for valleytronic applications.

  15. First-principles prediction of Tl/SiC for valleytronics

    KAUST Repository

    Xu, Zhen

    2017-09-22

    Recently, monolayer Tl on a Si or Ge substrate has been proposed for potential valleytronic systems. However, the band gaps of these systems are less than 0.1 eV, which is too small to be applied because an electric field or magnetic doping will reduce the band gaps further for the systems to become metallic. Here, we investigate SiC as an alternative substrate. By first-principles calculations we demonstrate that monolayer Tl can be grown on SiC. There are two valleys around the K/K′ points and the Berry curvature shows that the two valleys are inequivalent, indicating valley pseudospin. Moreover, due to the larger band gap of SiC (3.3 eV), the band gap of the Tl/SiC system is 0.6 eV, which is large enough for valley manipulation. Furthermore, we demonstrate that Cr doping can achieve valley polarization. Our study shows that the Tl/SiC system is promising for valleytronic applications.

  16. Comparison of PVT and NaI(Tl) scintillators for vehicle portal monitor applications

    International Nuclear Information System (INIS)

    Siciliano, E.R.; Ely, J.H.; Kouzes, R.T.; Milbrath, B.D.; Schweppe, J.E.; Stromswold, D.C.

    2005-01-01

    The demand for radiation portal monitor (RPM) systems has increased, and their capabilities are being further scrutinized as they are being applied to the task of detecting nuclear weapons, special nuclear material, and radiation dispersal device materials that could appear at borders. The requirements and constraints on RPM systems deployed at high-volume border crossings are significantly different from those at weapons facilities or steel recycling plants, where RPMs have been historically employed. In this new homeland security application, RPM systems must rapidly detect localized sources of radiation with a very high detection probability and low false-alarm rate, while screening all of the traffic without impeding the flow of commerce. In light of this new Department of Homeland Security application, the capabilities of two popular gamma-ray-detector materials as applied to these needs are re-examined. Both experimental data and computer simulations, together with practical deployment experience, are used to assess currently available polyvinyltoluene and NaI(Tl) gamma-ray detectors for border applications

  17. Myocardial viability assessed by Tl-201 SPECT. Redistribution versus reinjection

    International Nuclear Information System (INIS)

    Chalela, William Azem; Pimentel, Flavio Ferrarini de Oliveira; Uchida, Augusto Hiroshi; Bottega, Augusto; Ramires, Jose Antonio Franchine; Izaki, Marisa; Moraes, Aguinaldo Pereira; Soares Junior, Jose; Giorgi, Maria C. Pinto; Moffa, Paulo Jorge; Bellotti, Giovanni; Giovanni Guido Cerri; Meneghetti, Jose Claudio

    1994-01-01

    The purpose of this study was to verify if a third series of images acquired by reinjection thallium-201, 24 h after conventional myocardial perfusion with the radioisotope, improves the identification of myocardial viability segments. The methods: we studied 30 patients, mean age 57.7 ±9.4 years, with old myocardial infarction using thallium (Tl)-201 SPECT, and we obtained three series of images (stress, redistribution after 4 h and reinjection after 24 h. Cardiac images were divided in 5 segments (apical, lateral, anterior, septal and inferior) and each one received a value by a score system according to the Tl-201 myocardial uptake (0=normal uptake; 1=mild hypoperfusion; 2=moderate hypoperfusion; 3=severe hypoperfusion or no myocardial uptake). We considered viable myocardium when the uptake of Tl-201 in the segment related to te myocardial infarction increases at least 1 point in two different axis of Tl-201 SPECT. The results: seven (23,3%) patients demonstrated increase of Tl-201 uptake only at reinjection images, showing a high efficacy of the method. Nine (30%) patients showed persistent hypoperfusion at all series of images suggesting only fibrosis in the are related to the infarction. Fourteen (46,7%) patients showed increase of Tl-201 concentration at redistribution images; among these patients, six showed improvement of myocardial uptake at reinjection. This condition was interpreted as regional chronic ischemic process: hibernating myocardium. The conclusion was that Tl-201 hypoperfusion at redistribution images without significant changes in relation to the stress images do not represent fibrosis at all. The reinjection technic was better than conventional redistribution in the detection of viable myocardium. This data allows a better therapeutic orientation. (author)

  18. A theoretical study of CsI:Tl columnar scintillator image quality parameters by analytical modeling

    Energy Technology Data Exchange (ETDEWEB)

    Kalyvas, N., E-mail: nkalyvas@teiath.gr; Valais, I.; Michail, C.; Fountos, G.; Kandarakis, I.; Cavouras, D.

    2015-04-11

    Medical X-ray digital imaging systems such as mammography, radiography and computed tomography (CT), are composed from efficient radiation detectors, which can transform the X-rays to electron signal. Scintillators are materials that emit light when excited by X-rays and incorporated in X-ray medical imaging detectors. Columnar scintillator, like CsI:T1 is very often used for X-ray detection due to its higher performance. The columnar form limits the lateral spread of the optical photons to the scintillator output, thus it demonstrates superior spatial resolution compared to granular scintillators. The aim of this work is to provide an analytical model for calculating the MTF, the DQE and the emission efficiency of a columnar scintillator. The model parameters were validated against published Monte Carlo data. The model was able to predict the overall performance of CsI:Tl scintillators and suggested an optimum thickness of 300 μm for radiography applications. - Highlights: • An analytical model for calculating MTF, DQE and Detector Optical Gain (DOG) of columnar phosphors was developed. • The model was fitted to published efficiency and MTF Monte Carlo data. • A good fit was observed for 300 µm columnar CsI:Tl thickness. • The performance of the 300 µm column thickness CsI:Tl was better in terms of MTF and DOG for radiographic applications.

  19. The X-ray response of TlBr

    International Nuclear Information System (INIS)

    Owens, Alan; Bavdaz, M.; Brammertz, G.; Gostilo, V.; Graafsma, H.; Kozorezov, A.; Krumrey, M.; Lisjutin, I.; Peacock, A.; Puig, A.; Sipila, H.; Zatoloka, S.

    2003-01-01

    We present the results of a series of X-ray measurements on several prototype TlBr detectors. The devices were fabricated from mono-crystalline material and were typically of size 2.7x2.7x0.8 mm 3 . The material is extremely pure, having impurity concentrations -4 and 1x10 -5 cm 2 V -1 , respectively, which are about an order of magnitude higher than previously reported values. Three detectors were fabricated and extensively tested over the energy range 2.3-100 keV at three synchrotron radiation facilities: the Physikalisch-Technische Bundesanstalt (PTB) laboratory at the Berliner Elektronenspeicherring fuer Synchrotronstrahlung (BESSY II), the European Synchrotron Radiation Research Facility (ESRF) and the Hamburger Synchrotron-strahlungslabor (HASYLAB) radiation facility. Room temperature energy resolutions under full-area illumination of 1.8 and 3.3 keV FWHM have been achieved at 5.9 and 59.95 keV, respectively. At reduced detector temperatures of -30 deg. C, these fall to 800 eV and 2.6 keV FWHM, respectively. Under monochromatic pencil beam illumination, the measured energy resolutions at 6 and 60 keV were 664 eV and ∼3 keV FWHM at the same temperature. For energies 2 , 12 keV mono-energetic X-ray beam, raster scanned over the forward active area. Whilst two detectors were spatially uniform to a level commensurate with statistics, the third was not. In all cases, evidence was found for charge collection problems caused by field fringing

  20. Use of universal functional optimisation for TL glow curve analysis

    International Nuclear Information System (INIS)

    Pernicka, F.; Linh, H.Q.

    1996-01-01

    The effective use of any TL instrument requires an efficient software package to be able to fulfil different tasks required by research and practical applications. One of the standard features of the package used at the NPI Prague is the application of the interactive modular system Universal Functional Optimisation (UFO) for glow curve deconvolution. The whole system has been tested on standard glow curves using different models of the TL process (a single peak described by the Podgorsak approximation, first order kinetics and/or general order kinetics). Calculated values of basic TL parameters (E and s) show a good agreement with the results obtained by other authors. The main advantage of the system is in its modularity that enables flexible changes in the TL model and mathematical procedures of the glow curve analysis. (author)

  1. Synthesis and TL/OSL properties of a novel high-sensitive blue-emitting LiSrPO{sub 4}:Eu{sup 2+} phosphor for radiation dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Palan, C.B.; Koparkar, K.A.; Omanwar, S.K. [Sant Gadge Baba Amravati University, Department of Physics, Amravati (India); Bajaj, N.S. [Toshniwal Arts, Commerce and Science College, Sengoan, Hingoli District, MH (India); Soni, A. [Bhabha Atomic Research Centre, Radiological Physics and Advisory Division, Mumbai (India)

    2016-07-15

    In this study, a series of Eu{sup 2+}-doped LiSrPO{sub 4} phosphors were synthesized via solid-state method. The structural and morphological characterizations were done through X-ray diffraction and scanning electronic microscope. Additionally, the photoluminescence (PL), thermoluminescence (TL) and optically stimulated luminescence (OSL) behaviours of LiSrPO{sub 4}:Eu{sup 2+} phosphors were studied. The LiSrPO{sub 4}:Eu{sup 2+} phosphor shows OSL sensitivity about 8 times than that of α-Al{sub 2}O{sub 3}:C phosphor and 6 times than that of LiMgPO{sub 4}:Tb{sup 3+}, B phosphor. Moreover, TL sensitivity was about 15 times more as compared to α-Al{sub 2}O{sub 3}:C phosphor. The kinetic parameters of TL curve were calculated using peak shape method. In TL/OSL mode, dose-response was almost linear nature, in the range of measurement. The minimum detectable dose was found to be 25.18 μGy with 3σ of background. Also, reusability was also studies, which shows the phosphor can be reusable for 10 cycles with 0.1 % change in OSL output. (orig.)

  2. Detection of irradiated foods by the thermoluminescence. Relationships between the temperature ranges of integrating TL glow curves and TL glow ratios

    International Nuclear Information System (INIS)

    Sekiguchi, Masayuki; Yamazaki, Masao; Goto, Michiko; Todoriki, Setsuko; Hagiwara, Shoji

    2007-01-01

    Our study demonstrated that the effects of the several temperature ranges for integrating TL glow intensity on the TL glow ratios by using spice-set purchased at a Turkish air port. The spice set had no labeling of irradiation feeds, but nine of 12 spices were judged as irradiated food in this study. Those temperature ranges were defined by evaluating the glow curves of irradiated TLD-100 chip (167-230degC), TLD-100 disc (177-238degC) and Dolomite element (145-258degC). Those are relatively stable and the difference of typical glow peak temperatures of TLD-100 disc in two institutes was less than 2%. On the other hand, those of TLD-100 tip was shift to higher temperature side at about 4degC because of declining of thermal conductance. The temperature ranges defined by TLD-100 were showed that discriminate more clearly between irradiated and nonirradiated spices compared with the full temperature range of TL measurement (70-400degC). With the exception of low glow intensity, background measurement for estimating net glow intensity was not necessary because TL glow ratio was hardly influenced whether the background measured or not. (author)

  3. Stability of detecting system using NaI(Tl)

    International Nuclear Information System (INIS)

    Zhuo Yunshang; Lei Zhangyun; Zen Yu; Gong Hua

    1996-01-01

    A detecting system using NaI(Tl) is widely used in research and industry of nuclear science and other fields. For providing the high accuracy and working well under inclement environment, the stability of detecting system using NaI(Tl) is very important. The variation of environment temperature, the change of counting rate and long time continuous working of detector will cause un-negligible effect on the measurement. Three approaches were used. They are: 1) temperature control (It makes the effect of the variation of environment temperature on the measurement negligible.); 2) spectrum stabilizing (It adjust the peak position of the spectrum when the counting rate changes.); and 3) auto-checking and adjusting (It adjusts the drift of the NaI(Tl) detecting system when it works continuously)

  4. Interlaboratory tests to identify irradiation treatment of various foods via gas chromatographic detection of hydrocarbons, ESR spectroscopy and TL analysis

    Energy Technology Data Exchange (ETDEWEB)

    Schreiber, G.A.; Helle, N.; Schulzki, G.; Linke, B.; Spiegelberg, A.; Mager, M.; Boegl, K.W. [BgVV - Federal Inst. for Health Protection of Consumers and Veterinary Medicine, Berlin (Germany)

    1996-12-31

    The gas chromatographic (GC) analysis of radiation-induced volatile hydrocarbons (HC) and 2-alkylcyclobutanones, the ESR spectroscopic detection of radiation-specific radicals and the thermoluminescence (TL) analysis of silicate mineral are the most important methods for identification of irradiated foods. After successful performance in interlaboratory studies on meat products, fish, spices, herbs and shells of nuts, all or some of these methods have been approved by national authorities in Germany and the United Kingdom. Recently, draft European Standards have been elaborated for approval by member states of the European Committee for Standardization (CEN). Several research laboratories have shown that these methods can be applied to various foods not yet tested in collaborative studies. However, for an effective application in food control it is necessary to prove their suitability in interlaboratory studies. Therefore, in 1993/94, various interlaboratory tests were organised by the BgVV. In an ESR spectroscopic test, shrimps and paprika powder were examined. Shrimps were also the subject of examination in a TL test. Finally, GC detection of radiation-induced hydrocarbons in the fat fraction of foods was used in another test to identify irradiated Camembert, avocado, papaya and mango. In the following paper, results of the interlaboratory tests are summarised. Detailed reports are published by this institute. (author).

  5. Interlaboratory tests to identify irradiation treatment of various foods via gas chromatographic detection of hydrocarbons, ESR spectroscopy and TL analysis

    International Nuclear Information System (INIS)

    Schreiber, G.A.; Helle, N.; Schulzki, G.; Linke, B.; Spiegelberg, A.; Mager, M.; Boegl, K.W.

    1996-01-01

    The gas chromatographic (GC) analysis of radiation-induced volatile hydrocarbons (HC) and 2-alkylcyclobutanones, the ESR spectroscopic detection of radiation-specific radicals and the thermoluminescence (TL) analysis of silicate mineral are the most important methods for identification of irradiated foods. After successful performance in interlaboratory studies on meat products, fish, spices, herbs and shells of nuts, all or some of these methods have been approved by national authorities in Germany and the United Kingdom. Recently, draft European Standards have been elaborated for approval by member states of the European Committee for Standardization (CEN). Several research laboratories have shown that these methods can be applied to various foods not yet tested in collaborative studies. However, for an effective application in food control it is necessary to prove their suitability in interlaboratory studies. Therefore, in 1993/94, various interlaboratory tests were organised by the BgVV. In an ESR spectroscopic test, shrimps and paprika powder were examined. Shrimps were also the subject of examination in a TL test. Finally, GC detection of radiation-induced hydrocarbons in the fat fraction of foods was used in another test to identify irradiated Camembert, avocado, papaya and mango. In the following paper, results of the interlaboratory tests are summarised. Detailed reports are published by this institute. (author)

  6. Investigating the origins of double photopeaks in CsI:Tl samples through activator mapping

    Science.gov (United States)

    Onken, Drew R.; Gridin, Sergii; Williams, Richard T.; Williams, Charles B.; Donati, George L.; Gayshan, Vadim; Vasyukov, Sergey; Gektin, Alex

    2018-06-01

    Careful examination of the origins of double photopeaks in CsI:Tl provides a foundation for exploring the relationship between activator homogeneity and photopeak resolution in scintillators. In rare cases, certain CsI:Tl crystals exhibit a second photopeak in the pulse-height spectrum. A combination of optical mapping and ICP-MS measurements reveals the presence of two distinct regions with differing Tl concentrations in these crystals. The oscillator strength of the 299 nm absorption A-band of Tl in CsI was measured to be 0.0526 ± 0.0008; this parameter can be used to quantify activator concentration from the optical absorption. Using published measurements of luminescence intensity versus Tl concentration, the distributions of Tl measured from optical absorption maps of the samples were reconstructed into photopeaks in good agreement with experiment. The distribution of Tl concentrations in these particular crystals allowed examining luminescence pulse shape as a function of Tl concentration.

  7. Exploring the thermoelectric and magnetic properties of uranium selenides: Tl{sub 2}Ag{sub 2}USe{sub 4} and Tl{sub 3}Cu{sub 4}USe{sub 6}

    Energy Technology Data Exchange (ETDEWEB)

    Azam, Sikander; Khan, Saleem Ayaz [New Technologies – Research Center, University of West Bohemia, Univerzitni 8, 30614 Pilsen (Czech Republic); Din, Haleem Ud [Department of Physics, Hazara University, Mansehra (Pakistan); Khenata, Rabah [Laboratoire de Physique Quantique et de Modélisation Mathématique (LPQ3M), Département de Technologie, Université de Mascara, Mascara 29000 (Algeria); Goumri-Said, Souraya, E-mail: sosaid@alfaisal.edu [College of Science, Physics department, Alfaisal University, P.O. Box 50927, Riyadh 11533 (Saudi Arabia)

    2016-09-01

    The electronic, magnetic and thermoelectric properties of Tl{sub 2}Ag{sub 2}USe{sub 4} and Tl{sub 3}Cu{sub 4}USe{sub 6} compounds were investigated using the full potential linear augmented plane wave (FP-LAPW) method based on the density functional theory (DFT). The exchange correlation was treated with the generalized gradient approximation plus optimized effective Hubbard parameter and spin–orbit coupling (GGA+U+SOC). The present uranium selenides show narrow direct energy band gap values of 0.7 and 0.875 eV for Tl{sub 2}Ag{sub 2}USe{sub 4} and Tl{sub 3}Cu{sub 4}USe{sub 6} respectively. For both selenides U-d/f states are responsible for electrical transport properties. Uranium atoms were the most contributors in the magnetic moment compared to other atoms and show ferromagnetic nature. The spin density isosurfaces show the polarization of neighboring atoms of Uranium, such as silver/copper and selenium. Thermoelectric calculations reveal that Tl{sub 3}Cu{sub 4}USe{sub 6} is more suitable for thermoelectric device applications than Tl{sub 2}Ag{sub 2}USe{sub 4}. - Highlights: • Electronic, magnetic and thermoelectric properties of uranium selenides are investigated with DFT. • They show a narrow direct energy band gap of 0.7 and 0.875 eV. • U-d/f states are responsible for electrical transport properties. • Tl{sub 3}Cu{sub 4}USe{sub 6} is more suitable for thermoelectric device applications than Tl{sub 2}Ag{sub 2}USe{sub 4}.

  8. Fading of the Tl signal in LiF: Mg, Cu, P during a large post irradiation period; Desvanecimiento de la senal Tl en LiF: Mg, Cu, P durante un largo periodo posradiacion

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, P.R. [ININ, A.P. 18-1027, 11801 Mexico D.F. (Mexico); Azorin, J. [UAM-I, 09340 Mexico D.F. (Mexico); Furetta, C. [Universidad de Roma, Piazzale Aldo Moro 2, Roma (Italy)

    2004-07-01

    In this work the obtained results of the study of the fading of the Tl signal in dosemeters of LiF activated with magnesium, copper and phosphorus (LiF:Mg,Cu,P) are presented. The studied dosemeters were LiF: Mg,Cu,P + Ptfe, developed in the ININ, taking like reference to the commercial dosemeter GR200A of Chinese manufacture. In both cases the Tl curve presents four peaks; in LiF: Mg,Cu,P + Ptfe, the peaks of smaller size appear in 359 K, 389 K and 447 K, the main dosimetric peak appears in 486 K; in GR200A, the peaks of smaller size appear in 360 K, 389 K and 445 K; while the main dosimetric peak appears in 487 K. The highest fading shown by the dosemeters of LiF: Mg,Cu,P + Ptfe, it was of 3.07%, value very below the one recommended for dosimetric purposes. While the commercial dosemeters presented a fading until of 6.23%, surpassing with the recommended values. The observed fading, it corresponds to the lost of the Tl signal of the peaks 1 and 2, since the first one disappears few hours after the irradiation, while the peak 2, it disappears completely after 94 days, the peak 3 remained stable during the six months of study, while the peak 4, it showed a slight increment due to the contribution of the dose of natural environmental radiation. (Author)

  9. Physical properties and thermoluminescence of glasses designed for radiation dosimetry measurements

    International Nuclear Information System (INIS)

    Laopaiboon, R.; Bootjomchai, C.

    2015-01-01

    Highlights: • TL stability of soda-lime glass was corrected by dopants. • D LDL values indicated that the glass samples have good radiation sensitivity. • Bond compression model theory was used to confirm the results from experimental. • High elastic moduli of glass samples indicated that high stability of structure. - Abstract: Soda lime glasses doped with CeO 2 , Nd 2 O 3 and MnO 2 were prepared. Thermoluminescence (TL) properties, such as glow curves and linearity of TL response on irradiation dose were investigated. Results showed that the TL properties depended on the type and concentration of the dopants. Samples were selected to calculate energy trap depth parameters. To design materials for radiation dosimetry, physical properties, ion concentration, elastic properties and effective atomic numbers are important. Theoretical bond compression models were used to determine the elastic moduli for comparison with experimental values. Results show fair agreement between theoretical and experimental measurements. The high elastic moduli of the glass samples indicated high rigidity and stability of the glass matrix structure

  10. Clinical use of 201Tl myocardial scintigraphy

    International Nuclear Information System (INIS)

    Senda, Kohei; Imaeda, Takeyoshi; Kato, Toshimitsu; Asada, Shuichi; Doi, Hidetaka

    1977-01-01

    Myocardial imaging with 201 Tl and scinticamera was studied experimentally using specially designed phantoms and clinically in 23 patients with myocardial infarction or other heart disease. In the phantom experiment, quality of image, accumulative count rate, and detectability of the defect were compared to obtain the best technique for their detection, using four different collimators, i.e., converging, pin-hole, 4000-hole, and 140 keV high-resolution, at two photopeak levels of 201 Tl of 75 and 167 keV, and combining a radiation absorber. In patient examination, myocardial images taken at different periods after injection, different detecting conditions of the scinticamera, and various detecting projections were compared. Images of the converging collimator at the 75 keV photopeak revealed considerably higher accumulative counts and relatively higher quality than those of other detecting conditions. It was necessary to take as many images as possible in various projections, in order to detect the location and size of the myocardial ischemic lesion because the lesion was demonstrated as a clear defect only in profile. It became evident that images taken between about 25 and 90 min delineated the myocardium more clearly than those taken in other periods. Normal images taken in 8 patients without ischemic heart disease appeared in the shape of a doughnut of horseshoe, demonstrating mainly the left venticular myocardium. The image was faint in the region of the aortic or mitral valve and thin in the region of the apical wall. A faint image of the right ventricular myocardium was sometimes seen. In 3 patients with valvular heart disease, findings suggested changes in the thickness of myocardium and the distribution of coronary blood flow. In 11 of 12 patients with old myocardial infarction, the location and size of the lesion was detected. (Evans, J.)

  11. Magnetic properties of Bi- and Tl- based new high-Tc superconductors

    International Nuclear Information System (INIS)

    Togano, K.; Kumakura, H.; Dietderich, D.H.

    1988-01-01

    Upper critical field H c2 and Magnetization curve were measured for new high-T c oxide superconductors of Bi-Sr-Ca-Cu-O and Tl-Ba-Ca-Cu-O systems. H c2 values at 77K for the high-T phase of Bi-Sr-Ca-Cu-O, low-T c (T c (ρ = 0) = 105K) phase of Tl-Ba-Ca-Cu-O, and high-T c (T c (ρ = 0)=115K) phase of Tl-Ba-Ca-Cu-O are 41T, 50T, and 100T, respectively. The magnetization curve of the Bi-Sr-Ca-Cu-O shows a relatively small hysterisis, suggesting a weak pinning force compared to Tl-Ba-Ca-Cu-O as well as Ba 2 YCU 3 O x . Critical current density J c of 600A/Cm 2 at 77K and zero-magnetiac field was attained for the high-T c sample of Tl-Ba-Ca-Cu-O

  12. Measurement of the infarcted area by 201Tl myocardial emission CT

    International Nuclear Information System (INIS)

    Tamaki, Shunichi; Murakami, Tomoyuki; Kambara, Hirofumi

    1982-01-01

    201 Tl-ECT was performed in 28 cases 4 weeks after the onset of acute myocardial infarction to calculate the volume of infarction for comparison with the CK-MB infarction size obtained in the acute phase. The infarct area obtained by two-dimensional 201 Tl scintigraphy in 18 cases treated by the conventional method showed a positive correlation with the CK-MB infarct size, but the volume of infarction by 201 Tl-ECT produced a better correlation. In the group with successful thrombolysis, the serum CK-MB level reached a peak soon after the onset, accompanied by release of more CK-MB for a constant volume of infarction obtained by 201 Tl-ECT, as compared with the group with unsuccessful thrombolysis or conventional therapy. This suggests the involvement of washout phenomenon by reperfusion. Although there are some limitations, the three-dimensional detection of the distribution of myocardial blood flow by 201 Tl-ECT is useful, covering disadvantages of two-dimensional images. (Chiba, N.)

  13. Regional analysis of annual maximum rainfall using TL-moments method

    Science.gov (United States)

    Shabri, Ani Bin; Daud, Zalina Mohd; Ariff, Noratiqah Mohd

    2011-06-01

    Information related to distributions of rainfall amounts are of great importance for designs of water-related structures. One of the concerns of hydrologists and engineers is the probability distribution for modeling of regional data. In this study, a novel approach to regional frequency analysis using L-moments is revisited. Subsequently, an alternative regional frequency analysis using the TL-moments method is employed. The results from both methods were then compared. The analysis was based on daily annual maximum rainfall data from 40 stations in Selangor Malaysia. TL-moments for the generalized extreme value (GEV) and generalized logistic (GLO) distributions were derived and used to develop the regional frequency analysis procedure. TL-moment ratio diagram and Z-test were employed in determining the best-fit distribution. Comparison between the two approaches showed that the L-moments and TL-moments produced equivalent results. GLO and GEV distributions were identified as the most suitable distributions for representing the statistical properties of extreme rainfall in Selangor. Monte Carlo simulation was used for performance evaluation, and it showed that the method of TL-moments was more efficient for lower quantile estimation compared with the L-moments.

  14. TL dating of vases with elephant ears in Yuan Dynasty

    International Nuclear Information System (INIS)

    Xia Junding; Wang Weida; Leung, P.L.

    2005-01-01

    Thermoluminescence (TL) dating using an activation method in pre-dose technique was described. Three vases in underglaze blue with elephant ears and one vase in underglaze red with elephant ears in Yuan Dynasty were dated by this method. The results show that the TL ages are all less than 100 a B.P., and in which sbc 648 and sbc 649 were imitated in recent years. This method is quick, convenient and reliable for porcelain dating with the age of less than 1000 a B.P.. As a comparison, a porcelain sample with underglaze blue in Yuan Dynasty was dated too, and its TL age is 620 ± 140 B.P.. In addition, some complex factors associated with dating have been discussed and a resolution has been raised, which will help improve the accuracy of TL dating. (authors)

  15. Dipyridamole 201Tl scintigraphy in the evaluation of prognosis after myocardial infarction

    International Nuclear Information System (INIS)

    Okada, R.D.; Glover, D.K.; Leppo, J.A.

    1991-01-01

    Dipyridamole 201Tl imaging has been proposed as an alternative to exercise ECG testing for the prehospital discharge evaluation of patients recovering from myocardial infarction. The rationale is that many postinfarction patients with exercise-induced ischemia experience later cardiac events, and the sensitivity of predischarge exercise ECG testing in patients with multivessel disease ranges from only 45% to 62%. In addition, several groups of investigators have shown the sensitivity of submaximum exercise 201Tl imaging to be less than ideal. This report summarizes the current status of dipyridamole 201Tl imaging in the period of 1-13 days after myocardial infarction. Although the number of studies performed to date is limited, the following conclusions can be drawn: dipyridamole 201Tl imaging after myocardial infarction was associated with no serious side effects, and those present could be quickly reversed with aminophylline; redistribution with dipyridamole 201Tl images definitely correlates with prognosis after uncomplicated myocardial infarction; dipyridamole 201Tl imaging is definitely useful in patients unable to exercise for a variety of reasons; and future studies are definitely indicated to further define the role of dipyridamole 201Tl imaging for assessing prognosis, especially in those patients undergoing interventional therapy after acute myocardial infarction

  16. Degradation of myocardial perfusion SPECT images caused by contaminants in thallous (201Tl) chloride

    International Nuclear Information System (INIS)

    Staelens, Steven G.; Wit, Tim C. de; Lemahieu, Ignace A.; Beekman, Freek J.

    2008-01-01

    Thallous ( 201 Tl) chloride is a single-photon emission computed tomography (SPECT) tracer mainly used for assessing perfusion and viability of myocardial tissue. 201 Tl emits X-rays around 72 keV and gammas at 167 keV, and has a half-life of 73 h. Regulations allow an intrinsic contamination up to 3-5%, which is mainly caused by 200 Tl (368 keV; 26 h) and by 202 Tl (439 keV; 12.2 days). Contra-intuitive to the low-level percentages in which these contaminants are present, their impact may be significant because of much higher gamma camera sensitivity for these high-energy photon emissions. Therefore, we investigate the effects of the contaminants in terms of detected fractions of photons in projections and contrast degradation in reconstructed images. Acquisitions of a digital thorax phantom filled with thallous ( 201 Tl) chloride were simulated with a validated Monte Carlo tool, thereby, modelling 1% of contamination by 200 Tl and 202 Tl each. In addition, measurements of a thorax phantom on a dual-headed gamma camera were performed. The product used was contaminated by 0.17% of 200 Tl and 0.24% of 202 Tl at activity reference time (ART). This ART is specified by the manufacturer, thereby, accounting for the difference in half-lives of 201 Tl and its contaminants. These measurements were repeated at different dates associated with various contamination levels. Simulations showed that, with 1% of 200 Tl and 202 Tl, the total contamination in the 72 keV window can rise up to one out of three detected photons. For the 167keV window, the contamination is even more pronounced: more than four out of five detections in this photopeak window originate from contaminants. Measurements indicate that cold lesion contrast in myocardial perfusion SPECT imaging is at maximum close to ART. In addition to a higher noise level, relative contrast decreases 15% 2 days early to ART, which is explained by an increase in 200 Tl contamination. After ART, contrast decreased by 16% when

  17. Evidence for charge Kondo effect in superconducting Tl-doped PbTe

    Energy Technology Data Exchange (ETDEWEB)

    Fisher, I

    2010-01-11

    We report results of low-temperature thermodynamic and transport measurements of Pb{sub 1-x}Tl{sub x}Te single crystals for Tl concentrations up to the solubility limit of approximately x = 1.5%. For all doped samples, we observe a low-temperature resistivity upturn that scales in magnitude with the Tl concentration. The temperature and field dependence of this upturn are consistent with a charge Kondo effect involving degenerate Tl valence states differing by two electrons, with a characteristic Kondo temperature T{sub K} {approx} 6 K. The observation of such an effect supports an electronic pairing mechanism for superconductivity in this material and may account for the anomalously high T{sub c} values.

  18. Thermoluminescence characteristics of Ge-doped optical fibers with different dimensions for radiation dosimetry

    International Nuclear Information System (INIS)

    Begum, Mahfuza; Rahman, A.K.M. Mizanur; Abdul-Rashid, H.A.; Yusoff, Z.; Begum, Mahbuba; Mat-Sharif, K.A.; Amin, Y.M.; Bradley, D.A.

    2015-01-01

    Important thermoluminescence (TL) properties of five (5) different core sizes Ge-doped optical fibers have been studied to develop new TL material with better response. These are drawn from same preform applying different speed and tension during drawing phase to produce Ge-doped optical fibers with five (5) different core sizes. The results of the investigations are also compared with most commonly used standard TLD-100 chips (LiF:Mg,Ti) and commercial multimode Ge-doped optical fiber (Yangtze Optical Fiber, China). Scanning Electron Microscope (SEM) and EDX analysis of the fibers are also performed to map Ge distribution across the deposited region. Standard Gamma radiation source in Secondary Standard Dosimetry Lab (SSDL) was used for irradiation covering dose range from 1 Gy to 10 Gy. The essential dosimetric parameters that have been studied are TL linearity, reproducibility and fading. Prior to irradiation all samples ∼0.5 cm length are annealed at temperature of 400 °C for 1 h period to standardize their sensitivities and background. Standard TLD-100 chips are also annealed for 1 h at 400 °C and subsequently 2 h at 100 °C to yield the highest sensitivity. TL responses of these fibers show linearity over a wide gamma radiation dose that is an important property for radiation dosimetry. Among all fibers used in this study, 100 μm core diameter fiber provides highest response that is 2.6 times than that of smallest core (20 μm core) optical fiber. These fiber-samples demonstrate better response than commercial multi-mode optical fiber and also provide low degree of fading about 20% over a period of fifteen days for gamma radiation. Effective atomic number (Z eff ) is found in the range (13.25–13.69) which is higher than soft tissue (7.5) however within the range of human-bone (11.6–13.8). All the fibers can also be re-used several times as a detector after annealing. TL properties of the Ge-doped optical fibers indicate promising applications in

  19. Clinical application of 201Tl scintigraphy in patients with cold thyroid nodules

    International Nuclear Information System (INIS)

    Tonami, N.; Bunko, H.; Michigishi, T.; Kuwajima, A.; Hisada, K.

    1978-01-01

    201 Tl-chloride scintigraphy was performed in 45 patients with cold thyroid nodules. The 201 Tl scintigram was positive in 17 of 18 thyroid patients with cancer (94.4%), 8 of 20 patients with an adenoma (40.0%), 1 of 2 adenomatous goiter patients (50.5%), and all of 5 cases of chronic thyroiditis (100.0%). When the cold nodule was demonstrated to be positive with 201 Tl, the statistical chance of the lesion being a cellular one was 100.0% and a risk of its malignancy was 54.8%. On the other hand, the nodule with negative 201 Tl concentration had a 14.3% chance of cellularity and a 7.1% risk of malignancy. Thus, 201 Tl scintigraphy is of use in the differential diagnosis of the cold thyroid nodule

  20. Thermoluminescence of LaAlO3 crystals doped with Eu and Ce - Dy ions exposed to ultraviolet and gamma radiation

    International Nuclear Information System (INIS)

    Oliveira, Vitor H.; Faria, Luiz O.; Silva, Edna S.

    2011-01-01

    Due to environmental problems such as degradation of the ozone layer and control of radiation levels in units of radiation, new dosimetric materials with high sensitivity for ultraviolet (UV) and gamma radiation are of great interest for applications in environmental dosimetry. In this context, this paper presents the results of a systematic investigation of the thermoluminescent (TL) response of LaAlO 3 crystals doped with different concentrations of trivalent optically active ions exposed to UV and gamma radiation doses. The work has been performed under a direct cooperation between the Institute of Inorganic Chemistry in Moscow (IGIC), responsible for crystal growth, and the Center for Development of Nuclear Technology (CDTN), responsible for the study of its luminescent properties. In this context, samples doped with 1% of Eu 3+ , 1% Ce 3+ , 5% of Ce 3+ and also co-doped with 5% Ce 3+ and 1% Dy 3+ were grown under hydrothermal conditions. The investigation was divided into two fronts, one for gamma radiation and the other for UV radiation. In the investigation with gamma radiation the best TL response has been obtained from LaAlO 3 :Eu. This crystal has shown good sensitivity and excellent linearity between TL output and the delivered gamma doses ranging from 0.1 to 10.0 mGy. In addition, its TL curve is quite similar to the Al 2 O 3 :C, a commercial TL phosphor with high sensitivity to gamma radiation. In the investigation with UV radiation the best response has been achieved for co-doped LaAlO 3 :Ce,Dy. They have excellent sensitivity and good linearity for spectral irradiances ranging from 0.042 to 1.2 mJ.cm -2 . (author)

  1. Concepciones evolutivas acerca de la fabricación del dinero II: Los tipos de respuestas

    OpenAIRE

    Delval, Juan; Denegri Coria, Marianela

    2002-01-01

    En este artículo se profundiza en el análisis de los tipos de respuesta dados por los escolares ante cuestiones relativas al proceso de fabricación del dinero, teniendo en cuanta las diferencies en cuanto el nivel de complejidad de las respuestas aportadas por los sujetos de diferentes edades que fueron entrevistados. Ministerio de Ciencia y Tecnología (España) BSO2000-0064

  2. Scintigraphic detection of ischemic and other myocardial lesions using 201Tl

    International Nuclear Information System (INIS)

    Duska, F.; Novak, J.; Vizda, J.; Kubicek, J.; Kafka, P.

    1981-01-01

    Current knowledge of the myocardium scintiscanning using 201 Tl is briefly outlined. The principle is shown of 201 Tl cumulation in a healthy myocardium and the use of the radionuclide is justified. Heart scintiscanning after exercise or after administration of drugs increasing the blood flow through the coronaries allows detecting latent ischaemic heart disease. 201 Tl scintigraphy can also be used for diagnosing the myocardial infarction, angina pectoris and other heart diseases. (J.P.)

  3. Some methods for calibration and beta radiation dosimetry

    International Nuclear Information System (INIS)

    Caldas, Linda V. Ehlin

    1980-01-01

    The calibration of beta radiation was studied from the point of view of primary and secondary standardization, using extrapolation chambers and examining several effects. The properties of a commercial ionization chamber were investigated, and the possibility of its use in calibration and dosimetry of 90 Sr- 90 Y beta radiation was demonstrated . A secondary standard calibration facility was developed and the results obtained with this facility were compared with those obtained from a primary system directly or indirectly. Nearly energy independent response was obtained in.the range 60 keV to 0,8 MeV with this secondary standard. Two solid state techniques namely thermoluminescence (TL) and thermally stimulated exoelectron emission (TSEE) were also used for beta dosimetry. Various characteristics like reproducibility, response with dose,energy dependence, etc. were studied for the materials: LiF, CaF 2 ,Li 2 B 4 O 7 , Be O, CaSO 4 and Al 2 O 3 . TL detectors of thickness 0,9 mm underestimate the dose 60 μm thick CaSO 4 :Tm embedded on a thin aluminium plate gave energy independent response behind skin layers of 7 mg/cm 2 . Mixed field of beta, X and gamma radiation was analysed using this detector. Quartz based Be O and graphite based alpha beta-Al 2 O 3 were found to be good beta radiation detectors when the TSEE technique is used. Energy independent CaSO 4 :Tm TL dosimeters were used in international comparison for dose measurements and the results obtained were in agreement with the actual given doses within 10%. The TL detectors were also used for dose rate measurements from glazed painted tiles used in construction industry and a 85 Kr source used in textile and metal industries. Results obtained in the later case were Q compared with those using the secondary standard facility. (author)

  4. Vortex states of Tl2Ba2CuO6+δ studied via 205Tl NMR at 2 tesla

    International Nuclear Information System (INIS)

    Itoh, Yutaka; Michioka, Chishiro; Yoshimura, Kazuyoshi; Hayashi, Akihiko; Ueda, Yutaka

    2005-01-01

    We report a 205 Tl NMR study of vortex states in an aligned polycrystalline sample of an overdoped high-T c superconductor, Tl 2 Ba 2 CuO 6+δ (Tc - 85 K), at a magnetic field of 2 T along the c axis. We observed an imperfect vortex lattice, so-called Bragg glass, at T=5 K, the coexistence of vortex solid and vortex liquid between 10 and 60 K, and vortex melting between 65 and 85 K. No evidence for local antiferromagnetic ordering at vortex cores was found for our sample. (author)

  5. An intercomparison of detectors for measurement of background radiation

    International Nuclear Information System (INIS)

    Nielsen, S.P.; Boetter-Jensen, L.

    1981-04-01

    Measurements of the background radiation were made in 1978 at 14 locations with a high-pressure ionization chamber, thermoluminiscence dosimeters (TLD's), two NaI(Tl) detectors, and a Ge(Li) spectrometer system. Simultaneous measurements with the ionization chamber and the spectrometer system provide reliable estimates of the total background exposure rate, of the individual contributors to the terrestrial exposure rate, and of the exposure rate from the secondary cosmic radiation. The TLD results agree with those of the ionization chamber. The NaI(Tl) detector results show that accurate estimates of the terrestrial exposure rate can be obtained if empirical corrections are applied. (author)

  6. Estimation of ultraviolet radiation dose using CaF2:Tb phosphor

    International Nuclear Information System (INIS)

    Fukuda, Y.; Ohtaki, H.; Owaki, S.

    1996-01-01

    To observe and estimate the dose of ultraviolet (UV) radiation in sunlight, the available thermoluminescence (TL) materials were studied. Several kinds of lanthanide elements were doped in pure CaF 2 powdered crystal and the properties of the Tl for UV were observed. The TL intensity from CaF 2 :Tb was the highest among the samples doped with various lanthanide elements, and form the TL emission spectra (380-540 nm) the TL is estimated to be due to inner transition of Tb 3+ . The peak wavelength of the TL excitation light was located approximately at 235 nm and light of a longer wavelength than 320 nm was unable to excite the TL. The ultraviolet response of CaF 2 :Tb depended on its sintering temperature. Even without γ ray pre-irradiation the CaF 2 :Tb sample with 1 h exposure to sunlight has enough sensitivity to estimate the change of UV. Seasonal change of UV intensity in sunlight was measured with this TLD during four months in 1993. The results agreed with that of other institutes in Japan. (author)

  7. Differential diagnosis of thyroid diseases with 131I and 201TlCl scintigraphy

    International Nuclear Information System (INIS)

    Kumano, Machiko; Ishida, Osamu

    1979-01-01

    Scintigraphic study with 131 I and 201 TlCl was performed on the differential diagnosis of various kinds of thyroid disease. When thyroid nodules are cold by scintigraphy with 131 I and hot with 201 TlCl, the lesions were proved to be solid tumor, that is, mostly follicular adenoma and carcinoma, and also most probably chronic thyroiditis. Accumulation of 201 TlCl, however, is not observed in cystic lesions, and is very high with high frequency in metastatic lesion of the lymph nodes as well as the thyroid cancer, especially in well differentiated follicular carcinoma. Therefore 201 TlCl was very useful to confirm the metastatic tumors from the thyroid cancer. These features in accumulation of 131 I and 201 TlCl in thyroid disease suggest the imaging technique with 201 TlCl combined with 131 I seem to provide more pathological information on the thyroid and metastatic lesions. (author)

  8. Thermoluminescence of LaAlO{sub 3} crystals doped with Eu and Ce - Dy ions exposed to ultraviolet and gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Vitor H.; Faria, Luiz O., E-mail: farialo@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Silva, Edna S. [Universidade Federal de Minas Gerais (DEN/UFMG), Belo Horizonte, MG (Brazil). Dept. de Energia Nuclear; Khaidukov, Nicholas M. [Kurnakov Institute of General and Inorganic Chemistry, IGIC, Moscow (Russian Federation)

    2011-07-01

    Due to environmental problems such as degradation of the ozone layer and control of radiation levels in units of radiation, new dosimetric materials with high sensitivity for ultraviolet (UV) and gamma radiation are of great interest for applications in environmental dosimetry. In this context, this paper presents the results of a systematic investigation of the thermoluminescent (TL) response of LaAlO{sub 3} crystals doped with different concentrations of trivalent optically active ions exposed to UV and gamma radiation doses. The work has been performed under a direct cooperation between the Institute of Inorganic Chemistry in Moscow (IGIC), responsible for crystal growth, and the Center for Development of Nuclear Technology (CDTN), responsible for the study of its luminescent properties. In this context, samples doped with 1% of Eu{sup 3+}, 1% Ce{sup 3+}, 5% of Ce{sup 3+} and also co-doped with 5% Ce{sup 3+} and 1% Dy{sup 3+} were grown under hydrothermal conditions. The investigation was divided into two fronts, one for gamma radiation and the other for UV radiation. In the investigation with gamma radiation the best TL response has been obtained from LaAlO{sub 3}:Eu. This crystal has shown good sensitivity and excellent linearity between TL output and the delivered gamma doses ranging from 0.1 to 10.0 mGy. In addition, its TL curve is quite similar to the Al{sub 2}O{sub 3}:C, a commercial TL phosphor with high sensitivity to gamma radiation. In the investigation with UV radiation the best response has been achieved for co-doped LaAlO{sub 3}:Ce,Dy. They have excellent sensitivity and good linearity for spectral irradiances ranging from 0.042 to 1.2 mJ.cm{sup -2}. (author)

  9. Frecuencia de producción de las respuestas a 52 categorías verbales en niños de primaria

    Directory of Open Access Journals (Sweden)

    Edurne Goikoetxea

    2000-01-01

    Full Text Available Se presentan datos normativos de las respuestas a 52 categorías verbales de 484 niños de los cursos 1º a 6º de primaria (rango de edad = 6 a 13 años. Todas las categorías, excepto tres, se tomaron de los estudios de Soto et al. (1982/1994 y de Battig y Montague (1969. Los niños respondieron a cada categoría en 60 seg (1º y 2º curso o en 30 seg (3º a 6º curso. Se proporciona la frecuencia de producción de cada respuesta y el número de veces que cada respuesta apareció en primer lugar en cada categoría y curso, además del rango medio de cada respuesta en la muestra total. Se examina el número medio de respuestas, el número de ejemplares diferentes, el índice de respuestas comunes y el índice de diversidad, en cada categoría y curso. Los resultados se comparan con los de otras normas de niños y adultos. Estos datos son una herramienta para la investigación que emplea estímulos verbales, la docencia y el desarrollo de tests educativos y psicológicos.

  10. Super-ionic conductivity in (1D) nanofibrous TlGaTe2

    International Nuclear Information System (INIS)

    Sardarly, R.M.; Samedov, O.A.; Abdullaev, A.P.; Salmanov, F.T.; Urbanovic, A.; Garet, F.; Coutaz, J.-L.

    2010-01-01

    Full text : Nanodimension topologic-disorder materials constitute an important feature in the development of modern electronics. Among such materials, TlGaTe 2 is a p-type semiconductor with a nanofibrous structure Ga 3 +Te 2 - 2 groups form chains extending along the c-axis of the material. These negatively charged chains are bonded together by Tl+ ions. The resulting tetragonal lattice is characterized by a 18 D4h group symmetry. Recently, much attention has been paid to systems that behave as if they had less than 3 spatial dimensions. Such materials are often called quasi-one-dimensional (1D) nanorods, nanofibrous or nanochains. It was already studied the temperature dependence of conductivity σ (T) and current-voltage (I-V) characteristics of TlGaTe 2 . In the ohmic region of the I -V curve, σ (T) exhibits a behavior typical of hopping conductivity, which can be modeled in the framework of the Mott approximation. Moreover, it was determined the values of the density of localized states, the activation energy, the hop lengths, and the difference between the energies of states and the concentration of deep traps. The abrupt variation of the I-V curve is ascribed to the Pool-Frenkel thermal-field effect, which allows to obtain the concentration of ionized centers, the free-path lengths, the Frenkel coefficients and the shape of the potential well of TlGaTe 2 . For T>300 K, TlGaTe 2 crystals present interesting nonlinear electrical behaviors, such as switching effects and a negative-differential-resistance (NDR) region in their S-type I-V characteristics. In the NDR region, self-excited oscillations of the voltage were also observed. Here, it was investigated the temperature dependence of TlGaTe 2 crystals conductivity σ (T) in two experimental geometries, i.e. parallel and perpendicularly to the tetragonal c-axis of the crystal. The observed sharp increase of TlGaTe 2 conductivity results from a strong change of the number of the high-mobility ions. The

  11. AYUDA AL DESARROLLO Y RESPUESTA FISCAL EN CENTROAMÉRICA

    Directory of Open Access Journals (Sweden)

    Mariola Gozalo-Delgado

    2011-01-01

    Full Text Available En la actual etapa de crisis financiera global la mejora de la eficacia de la ayuda seha convertido en una prioridad tanto para los donantes como para los países recep-tores. En este contexto, comprender la manera en la que los gobiernos receptoresutilizan la ayuda es una cuestión decisiva para valorar su eficacia. Este artículo de-sarrolla y estima un modelo de respuesta fiscal con ayuda anticipada. Costa Rica yNicaragua son los países seleccionados como estudios de caso. El supuesto princi-pal del modelo teórico es que parte de la ayuda puede ser anticipada por los gobier-nos y, por tanto, puede influir en su programación presupuestaria. La estimación deeste modelo revela una respuesta fiscal diferente en cada país, pero con un resultadocomún en ambos: la ayuda se destina fundamentalmente a apoyar la función deestabilización de la política fiscal, aliviando las necesidades de financiación pública.

  12. Abnormal 201Tl limb scan due to unilateral tremor

    International Nuclear Information System (INIS)

    Simons, M.; Schelstraete, K.; Bratzlavsky, M.

    1982-01-01

    A abnormal intra- and interextremity distribution pattern on 201 Tl was observed on the limb scan of a patient with a unilateral tremor. This is ascribed to the increased blood flow in the muscles responsible for the tremor. The suggestion is made that the existence of tremor should be considered as a possible explanation for unexpected abnormalities on 201 Tl limb scintigrams

  13. Substitution of indium for chromium in TlIn5−xCrxSe8: crystal structure of TlIn4.811(5Cr0.189(5Se8

    Directory of Open Access Journals (Sweden)

    Robin Lefèvre

    2017-04-01

    Full Text Available The new thallium penta(indium/chromium octaselenide, TlIn4.811(5Cr0.189(5Se8, has been synthesized by solid-state reaction. It crystallizes isotypically with TlIn5Se8 in the space group C2/m. Although the two Tl positions are disordered and only partially occupied, no Tl deficiency was observed. The insertion of chromium in the structure has been confirmed by EDS analysis. Chromium substitutes indium exclusively at one of three In sites, viz. at one of the positions with site symmetry 2/m (Wyckoff position 2a. In the crystal structure, edge-sharing InSe6 octahedra, and (In,CrSe6 octahedra and InSe4 tetrahedra make up two types of columns that are linked into a framework in which two different types of channels parallel to [010] are present. The Tl atoms are located in the larger of the channels, whereas the other, smaller channel remains unoccupied.

  14. Thermoluminescent characterization of thin films of aluminium oxide submitted to beta and gamma radiation

    International Nuclear Information System (INIS)

    Villagran, E.; Escobar A, L.; Camps, E.; Gonzalez, P.R.; Martinez A, L.

    2002-01-01

    By mean of the laser ablation technique, thin films of aluminium oxide have been deposited on kapton substrates. These films present thermoluminescent response (Tl) when they are exposed to beta and gamma radiation. The brilliance curves show two peaks between 112 C and 180 C. A dose-response relationship study was realized and the Tl kinetic parameters were determined using the computerized deconvolution of the brilliance curve (CGCD). The thin films of aluminium oxide have potential applications as ultra.thin radiation dosemeters. (Author)

  15. Self-trapping nature of Tl nanoclusters on the Si(111)-7x7 surface

    International Nuclear Information System (INIS)

    Hwang, C G; Kim, N D; Lee, G; Shin, S Y; Kim, J S; Chung, J W

    2008-01-01

    We have studied properties of thallium (Tl) nanoclusters formed on the Si(111)-7x7 surface at room temperature (RT) by utilizing photoemission spectroscopy (PES) and high-resolution electron-energy-loss spectroscopy (HREELS) combined with first principles calculations. Our PES data reveal that the surface states stemming from the Si substrate remain quite inert with Tl adsorption producing no Tl-induced state until saturation at Tl coverage θ=0.21 monolayers. Such a behavior, in sharp contrast with the extremely reactive surface states upon the formation of Na or Li nanoclusters, together with the presence of a unique Tl-induced loss peak in HREELS spectra suggests no strong Si-Tl bonding, and is well understood in terms of gradual filling of Si dangling bonds with increasing θ. Our calculation further indicates the presence of several metastable atomic structures of Tl nanoclusters at RT rapidly transforming from one to another faster than 10 10 flippings per second. We thus conclude that the highly mobile Tl atoms form self-trapped nanoclusters within the attractive basins of the Si substrate at RT with several metastable phases. The mobile and multi-phased nature of Tl nanoclusters not only accounts for all the existing experimental observations available at present, but also provides an example of self-trapping of atoms in a nanometre-scale region

  16. Recovery of 201Tl by ion exchange chromatography from proton bombarded thallium cyclotron targets

    International Nuclear Information System (INIS)

    Walt, T.N. van der; Naidoo, C.

    2000-01-01

    A method based on ion exchange chromatography is presented for the recovery of 201 Tl and its precursor 201 Pb from proton bombarded natural thallium cyclotron targets. After bombardment the target is dissolved in diluted nitric acid. Water, hydrazine and ammonium acetate are added to the solution and the lead radioisotopes separated from the thallium by cation exchange chromatography on a Bio-Rex 70 column. The sorbed lead radioisotopes are eluted with dilute nitric acid and the separation repeated on a second Bio-Rex 70 column. After elution of the remaining thallium the column is left for 32 hours and the 201 Tl formed by decay of 201 Pb is eluted with an ammonium acetate solution. The 201 Tl eluate is acidified with a HNO 3 -HBr-Br 2 mixture and the resulting solution is passed through an AG MP-1 anion exchanger column to remove any remaining lead isotopes. The 201 Tl is eluted with a hydrazine solution, the eluate evaporated to dryness and the 201 Tl finally dissolved in an appropriate solution to produce a 201 TlCl solution suitable for medical use. A high quality 201 Tl product is obtained containing ≤ 0.1 μg of Tl/mCi (37 MBq) 201 Tl. The radionuclidic impurities are less than the maximum values specified by the US Pharmacopoeia and the British Pharmacopoeia. (orig.)

  17. Advanced crystal growth techniques for thallium bromide semiconductor radiation detectors

    Science.gov (United States)

    Datta, Amlan; Becla, Piotr; Guguschev, Christo; Motakef, Shariar

    2018-02-01

    Thallium Bromide (TlBr) is a promising room-temperature radiation detector candidate with excellent charge transport properties. Currently, Travelling Molten Zone (TMZ) technique is widely used for growth of semiconductor-grade TlBr crystals. However, there are several challenges associated with this type of crystal growth process including lower yield, high thermal stress, and low crystal uniformity. To overcome these shortcomings of the current technique, several different crystal growth techniques have been implemented in this study. These include: Vertical Bridgman (VB), Physical Vapor Transport (PVT), Edge-defined Film-fed Growth (EFG), and Czochralski Growth (Cz). Techniques based on melt pulling (EFG and Cz) were demonstrated for the first time for semiconductor grade TlBr material. The viability of each process along with the associated challenges for TlBr growth has been discussed. The purity of the TlBr crystals along with its crystalline and electronic properties were analyzed and correlated with the growth techniques. Uncorrected 662 keV energy resolutions around 2% were obtained from 5 mm x 5 mm x 10 mm TlBr devices with virtual Frisch-grid configuration.

  18. Studies on (Eu2+/Ce3+) activated fluoroperovskites for radiation dosimetry

    International Nuclear Information System (INIS)

    Joseph Daniel, D.; Ramasamya, P.; Madhusoodanan, U.; Annalakshmi, O.

    2014-01-01

    Thermoluminescence dosimetry is based on the principle that the amount of light released by the phosphor material, which has been previously exposed to ionizing radiation, will depend on the radiation dose received by the material. KMgF 3 and NaMgF 3 belongs to a family of fluoroperovskites, ABX 3 , (where A-alkali metal, B-alkali earth X-halide ions). In this paper, we present the results of TL induced by β - irradiation in co-doped ( Eu 2+ Ce 3+ ) fluoride single crystals. TL dose response and fading at room temperature have also been studied

  19. Improvements in the Tl dosimetry for Radiotherapy; Mejoras en la dosimetria Tl para Radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Bustos, S.; Velez, G.; Rubio, M. [CEPROCOR. Arenales 230 Juniors Cordoba 5000 (Argentina)

    1998-12-31

    The thermoluminescent dosimetry (TLD) in vivo has been demonstrated to be one of the most reliable for the control of radiotherapeutic treatments, but the delay in the response is the main disadvantage in its applicability. In this work are presented important improvements and it is demonstrated that maintaining the accuracy and reliability of the technique, it is possible to accelerate the response times at a few hours. To realize this work is utilized a lecturer Harshaw 4000, dosemeters LiF-TLD-100 chips (3.1 x 3.1 x 0.89 mm{sup 3}) and rods (1 x 1 x 6 mm{sup 3}). With the implementation of a glow curve analysis program developed in CIEMAT, its obtained a Tl peaks separation in such manner rapid and accurate, by that the thermal treatment of dosemeters may be reduced at one unique annealing pre-irradiation for 1 hr at 400 Centigrade. It is realized a periodical and individual calibration of the TLD and a study of the factors which influencing the ratio Tl signal-dose as linearity, correction by energy, directional response and pride of Tl signal. the results of this study are introducing in a calculation list specially designed and which allows to obtain absorbed dose by TLD starting of the dates (dosimetric peaks area) which appear of the glow curves analysis. The dose is obtained with an accuracy less than 5 %. The dosemeters already irradiated (in vivo) are analysed and informed in only four hours, allowing a greater control of the treatment and a correction of the possible errors for the next session, still in bi fractional treatments. The method implemented results thus accurate, rapid and reliable. (Author)

  20. Bonding and M?ssbauer Isomer Shifts in (Tl,Pb) - 1223 Cuprate

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    By using the chemical bond theory of dielectric description,the chemical bond parameters of (Tl,Pb) - 1223 was calculated.The results show that the Sr-O,Tl-O,and Ca-O types of bond have higher ionic character and the Cu-O types of bond have more covalent character.M?ssbauer isomer shifts of 57Fe and 119Sn doped in (Tl,Pb) -1223 were calculated by using the chemical environmental factor,he,defined by covalency and electronic polarizability.Four valence state tin and three valence iron sites were identified in 57Fe,and 119Sn doped (Tl,Pb) -1223 superconductor.We conclude that all of the Fe atoms substitute the Cu at square planar Cu (1) site,whereas Sn prefers to substitute the square pyramidal Cu (2) site.

  1. Construction of radiation - induced metastasis model in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jong Kuk; Jang, Su Jin; Kang, Sung Wook; Kim, Jae Sung; Hwang, Sang Gu; Kang, Joo Hyun [Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of)

    2011-05-15

    In treatment of cancer, distant metastases are important limiting factor because an estimated 50% of all cancer patients will develop metastases, and the metastases are major causing of cancer treatment failure. Recently a few reports indicated {gamma}-radiation induced an increase of invasiveness of several cancer cells. In this study, we had tried to show the possibility that radiation could also induce metastasis in vivo system. To prove our hypothesis, we constructed primary tumor by using C6-TL transfectant cell line expressing HSV1-tk and firefly luciferase (fLuc), and then {gamma}-radiation was treated to xenografts locally. Treatment of {gamma}-radiation to primary C6-TL xenografts of mice reduced size of xenografts and elongated survival of mice than those of mock control mice. But we also show that {gamma}-radiation treatment was followed by the growth of dormant metastases in various organs including lung and intestine after 2-4 weeks of {gamma}-radiation treatment. When bioluminescence imaging indicated growth of tumor in organs in mice, we sacrificed the mice and repeat acquired bioluminescence imaging after repeatedly. These images presented tumor growth locations exactly in organs. Because metastatic tumor candidates have morphology of foci, biopsies were performed for histological analysis or PCR analysis to confirm metastases. In most foci, histological analysis indicated several features of typical cancer tissue and PCR analysis showed present of fLuc gene in metastases. Detection of fLuc gene in metastases indicated these foci were originated from primary C6-TL xenografts, and the results suggest that {gamma}-radiation could promote metastasis in vivo as well as in vitro system. Although we need to understand changes of intracellular signaling or physiological phenomena of the radiation-induced metastasis yet, these results also imply that {gamma}-radiation treatment only to cancer patients need to pay attention carefully, and development of new

  2. AG, TL, and IRSL dosimetric properties in X-ray irradiated HPHT diamond crystals

    Energy Technology Data Exchange (ETDEWEB)

    Gil-Tolano, M.I. [Programa de Posgrado, Departamento de Investigacion en Fisica, Universidad de Sonora, A. P. 5-088, Hermosillo, Sonora, 83190, Mexico (Mexico); Melendrez, R.; Lancheros-Olmos, J.C.; Soto-Puebla, D.; Chernov, V.; Pedroza-Montero, M.; Barboza-Flores, M. [Departamento de Investigacion en Fisica, Universidad de Sonora, A. P. 5-088, Hermosillo, Sonora, 83190, Mexico (Mexico); Castaneda, B. [Departamento de Fisica, Universidad de Sonora, Blvd. Luis Encinas y Rosales S/N, Hermosillo, Sonora, 83000, Mexico (Mexico)

    2014-10-15

    HPHT diamonds have been studied for several years for their potential in different applications. In previous studies it has been found that the thermoluminescence (TL) glow curves of ''as-grown'' HPHT diamonds are non-reproducible. In this work, we study the afterglow (AG), thermoluminescent (TL), and optically stimulated luminescence (OSL) response of commercial samples of synthetic HPHT type-Ib diamond crystals exposed to X-ray irradiation (0.75 mA, 35 kV) at a dose rate of 0.624 Gy/s, after a high gamma ({sup 60}Co) dose irradiation of 500 kGy followed by a thermal treatment at 1073 K for 1 h in nitrogen atmosphere. Deconvolution of the TL glow curves shows four peaks, located around 379, 509, 561, and 609 K. The crystals exhibit evident AG recorded for 300 s immediately after X-ray irradiation, due to the thermal emptying of the traps responsible for the low-temperature TL peaks (below 400 K). The stimulation of irradiated crystals with 870-nm light, creates pronounced OSL and destroys all TL peaks with the exception of the high-temperature peak at 609 K. The dose responses of the integrated AG, TL, and OSL are linear in the range of 0.6-5 Gy and saturated at higher doses. The reproducibility of AG, TL, and OSL measurements is about 5%. The fading in the first hour of storage in dark conditions at RT of TL signal of HPHT diamond is mainly associated to the emptying of the traps responsible for the 379-K TL peaks. (copyright 2014 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  3. Preparation of biaxially oriented TlCu-1234 thin films

    CERN Document Server

    Khan, N A; Tateai, F; Kojima, T; Ishida, K; Terada, N; Ihara, H

    1999-01-01

    The single phase of TlCu-1234 superconductor thin films is prepared for the first time by the amorphous phase epitaxy (APE) method, which is thallium treatment of sputtered amorphous phase at 900 degrees C for 1 h. The amorphous $9 phase is prepared by sputtering from the stoichiometric target composition CuBa/sub 2/Ca/sub 3/Cu/sub 4/O/sub 12-y/. The films on the SrTiO/sub 3/ substrate are aligned biaxially after the thallium treatment. Highly reproducible $9 TlCu-1234 films are prepared by this method. The XRD reflected a predominant single phase with the c-axis lattice constant of 18.74 AA. This lattice constant value is in between that of Cu-1234 (17.99 AA) and Tl-1234 (19.11 AA) . The $9 pole figure measurements of (103) reflection of the films showed a-axis-oriented crystals with Delta phi =0.8 degrees . The composition of the films after energy dispersive X-ray (EDX) measurements is Tl/sub 0.8/Cu/sub 0.2/Ba/sub $9 2/Ca/sub 3/Cu/sub 4/O /sub 12-y/. From the resistivity measurements, the T/sub c/ is 113 K...

  4. Photostimulated luminescence detection and radiation effects on cinnamon (Cinnamomum zeylanicum) spice

    International Nuclear Information System (INIS)

    Marcazzó, J.; Sanchez-Barrera, C.E.; Urbina-Zavala, A.; Cruz-Zaragoza, E.

    2015-01-01

    The increase of disease borne pathogens in foods has promoted the use of new technologies in order to eliminate these pathogen microorganisms and extend the shelf-life of the foodstuffs. In particular, Cinnamon (Cinnamomum zeylanicum) contains an important number of pathogen microorganisms and it is frequently sterilized by gamma radiation. However, it is important to develop the detection methods for irradiated food in order to keep the dose control and also to analyze the radiation effects in their chemical property. This work reports (i) the photostimulated luminescence (PSL) detection of irradiated cinnamon and thermoluminescence (TL) detection of the inorganic polymineral fraction separated from this spice, and (ii) the proximate chemical analysis carried out on fat, protein and dietetic fiber contents. The detection limits using the PSL and TL methods were 500 Gy and 10 Gy, respectively, and the fat content was increased significantly with the gamma dose that could be related to the lipid oxidation in the cinnamon. - Highlights: • Samples of cinnamon (Cinnamomum zeylanicum) were studied by TL and PSL methods. • The cinnamon was detected as irradiated at a dose of 500 Gy using PSL. • TL method shows an excellent linear response for doses lesser than 500 Gy. • A proximate chemical analysis was carried out on fat, protein and dietetic fiber. • The TL and PSL responses can be used for dose control in commercial cinnamon

  5. Determination of the dosimetric properties of ZrO2: Cu and it use in the ultraviolet radiation dosimetry

    International Nuclear Information System (INIS)

    Molina P, D.; Olvera T, L.; Azorin N, J.; Barrera S, M.; Soto E, A.M.; Rivera M, T.

    2006-01-01

    In this work the experimental results of studying the thermoluminescent characteristics (TL) of the zirconium oxide doped with copper (ZrO 2 : Cu) exposed to ultraviolet light of wavelength in the interval of 200-400 nm are presented. The material in powder form was prepared using the sol-gel method. The dosimetric characteristics studied includes the emission curve TL (curved TL), the thermoluminescent response in function of the wavelength, the minimum dose detectable and the lineality of the response. The TL response of the ZrO 2 : Cu in function of the wavelength presents two maxima, in 260 and 290 nm, respectively. The TL curve of the ZrO 2 : Cu showed two peaks, in 120 and 170 C, respectively, being its similar form for all the studied wavelengths. The response in function of the spectral irradiance results to be lineal in the interval from 160 to 2300 mJ/cm 2 . The obtained results when studying the TL properties of ZrO 2 : Cu exposed to the ultraviolet radiation show that it gathers dosimetric characteristics prominent to be used as an ultraviolet radiation dosemeter. (Author)

  6. Nuclear resonance fluorescence of {sup 203,205}Tl

    Energy Technology Data Exchange (ETDEWEB)

    Pfeifer, Fabian; Fritzsche, Matthias; Pietralla, Norbert; Savran, Deniz; Weller, Henry; Zweidinger, Markus [Institut fuer Kernphysik, Technische Universitaet, Darmstadt (Germany); Rusev, Gencho; Tonchev, Anton P.; Tornow, Werner [Triangle Universities Nuclear Laboratory, Duke University, Durham (United States); Zilges, Andreas [Institut fuer Kernphysik, Universitaet Koeln (Germany)

    2009-07-01

    In order to investigate the dipole strength distribution in Thalium isotopes we have studied Nuclear Resonance Fluorescence of a sample composed of natural Thallium (consisting of 30% {sup 203}Tl and 70% {sup 205}Tl). Unpolarized bremsstrahlung with photo energies up to 7.5 MeV was used at the High Intensity Photon Setup (HIPS) at S-DALINAC at the IKP Darmstadt. 24 fluorescent {gamma}-ray transitions were observed, 19 of them for the first time. For the assignment of the polarity of two prominent {gamma}-ray transitions, one at 4.7 MeV and one at 4.9 MeV, the polarized photon beam of the High Intensity {gamma}-ray Source (HI{gamma}S) at Duke University was used. The experiment at HI{gamma}S revealed the existence of a photo-excited state of {sup 205}Tl at an excitation energy of 4.971 MeV that exhibits a transition to the first excited state at 203 keV.

  7. Investigation and optimisation of mobile NaI(Tl) and 3He-based neutron detectors for finding point sources

    International Nuclear Information System (INIS)

    Nilsson, Jonas M.C.; Finck, Robert R.; Rääf, Christopher

    2015-01-01

    Neutron radiation produces high-energy gamma radiation through (n,γ) reactions in matter. This can be used to detect neutron sources indirectly using gamma spectrometers. The sensitivity of a gamma spectrometer to neutrons can be amplified by surrounding it with polyvinyl chloride (PVC). The hydrogen in the PVC acts as a moderator and the chlorine emits prompt gammas when a neutron is captured. A 4.7-l 3 He-based mobile neutron detector was compared to a 4-l NaI(Tl)-detector covered with PVC using this principle. Methods were also developed to optimise the measurement parameters of the systems. The detector systems were compared with regard to their ability to find 241 AmBe, 252 Cf and 238 Pu– 13 C neutron sources. Results from stationary measurements were used to calculate optimal integration times as well as minimum detectable neutron emission rates. It was found that the 3 He-based detector was more sensitive to 252 Cf sources whereas the NaI(Tl) detector was more sensitive to 241 AmBe and 238 Pu– 13 C sources. The results also indicated that the sensitivity of the detectors to sources at known distances could theoretically be improved by 60% by changing from fixed integration times to list mode in mobile surveys

  8. Preparation and biodistribution of [201Tl](III)vancomycin complex in normal rats

    International Nuclear Information System (INIS)

    Jalilian, A.R.; Hosseini, M.A.; Karimian, A.; Saddadi, F.; Sadeghi, M.

    2006-01-01

    Thallium-201 (T 1/2 = 3.04 days) in Tl + form was converted to Tl 3+ cation in presence of O 3 in 6 M HCl controlled by RTLC/gel electrophoresis methods. The final evaporated activity was reacted with vancomycin (VAN) in water to yield [ 201 Tl](III)VAN. The best results were obtained at room temperature in water after 30 min with a radiochemical yield >99%, after mixing the reactants followed by SPE purification using Si Sep-Pak. The studies showed that thallic ion is mostly incorporated into vancomycin with a radiochemical purity of more than 98 ± 1% by RTLC. A specific activity of about 4.14·10 10 Bq/mmol was obtained. Radiochemical purity and stability of 201 Tl-VAN in the preparation and in presence of human serum was determined up to 5.5 days. Biodistribution study of 201 Tl(III)-vancomycin in normal rats was performed up to 52 h. (authors)

  9. Comparative measurements on different thermoluminescence materials for the dosimetry in mixed radiation fields; Vergleichende Messungen an unterschiedlichen Thermolumineszenzmaterialien fuer die Dosimetrie in gemischten Strahlenfeldern

    Energy Technology Data Exchange (ETDEWEB)

    Pillath, J.; Uray, I.

    2006-05-15

    LiF-based thermoluminescence materials (TL materials) have proved efficient and become established for dosimetry for many years now. In combination with suitable filtrations or moderators, they permit high-precision measurements of the radiation doses of all types of radiation relevant in radiation protection. The development of highly sensitive LiF materials with a doping of Mg, P and Cu has made it possible to measure doses down to one {mu}Sv. The measurements presented here specifically serve to phenomenologically analyse the glow curve structure of normally and highly sensitive LiF-TL materials in mixed gamma-neutron radiation fields. The sensitivity of the different TL materials to different types of radiation and the influence of the radiation types and of the evaluation parameters on the structure of the glow curves is examined. It is made apparent how information about the composition and doses of the individual components of a radiation field can be obtained by decomposing the glow curve into its individual peaks. (orig.)

  10. Global parameterization and validation of a two-leaf light use efficiency model for predicting gross primary production across FLUXNET sites: TL-LUE Parameterization and Validation

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Yanlian [Jiangsu Provincial Key Laboratory of Geographic Information Science and Technology, School of Geographic and Oceanographic Sciences, Nanjing University, Nanjing China; Joint Center for Global Change Studies, Beijing China; Wu, Xiaocui [International Institute for Earth System Sciences, Nanjing University, Nanjing China; Joint Center for Global Change Studies, Beijing China; Ju, Weimin [International Institute for Earth System Sciences, Nanjing University, Nanjing China; Jiangsu Center for Collaborative Innovation in Geographic Information Resource Development and Application, Nanjing China; Chen, Jing M. [International Institute for Earth System Sciences, Nanjing University, Nanjing China; Joint Center for Global Change Studies, Beijing China; Wang, Shaoqiang [Key Laboratory of Ecosystem Network Observation and Modeling, Institute of Geographic Sciences and Natural Resources Research, Chinese Academy of Science, Beijing China; Wang, Huimin [Key Laboratory of Ecosystem Network Observation and Modeling, Institute of Geographic Sciences and Natural Resources Research, Chinese Academy of Science, Beijing China; Yuan, Wenping [State Key Laboratory of Earth Surface Processes and Resource Ecology, Future Earth Research Institute, Beijing Normal University, Beijing China; Andrew Black, T. [Faculty of Land and Food Systems, University of British Columbia, Vancouver British Columbia Canada; Jassal, Rachhpal [Faculty of Land and Food Systems, University of British Columbia, Vancouver British Columbia Canada; Ibrom, Andreas [Department of Environmental Engineering, Technical University of Denmark (DTU), Kgs. Lyngby Denmark; Han, Shijie [Institute of Applied Ecology, Chinese Academy of Sciences, Shenyang China; Yan, Junhua [South China Botanical Garden, Chinese Academy of Sciences, Guangzhou China; Margolis, Hank [Centre for Forest Studies, Faculty of Forestry, Geography and Geomatics, Laval University, Quebec City Quebec Canada; Roupsard, Olivier [CIRAD-Persyst, UMR Ecologie Fonctionnelle and Biogéochimie des Sols et Agroécosystèmes, SupAgro-CIRAD-INRA-IRD, Montpellier France; CATIE (Tropical Agricultural Centre for Research and Higher Education), Turrialba Costa Rica; Li, Yingnian [Northwest Institute of Plateau Biology, Chinese Academy of Sciences, Xining China; Zhao, Fenghua [Key Laboratory of Ecosystem Network Observation and Modeling, Institute of Geographic Sciences and Natural Resources Research, Chinese Academy of Science, Beijing China; Kiely, Gerard [Environmental Research Institute, Civil and Environmental Engineering Department, University College Cork, Cork Ireland; Starr, Gregory [Department of Biological Sciences, University of Alabama, Tuscaloosa Alabama USA; Pavelka, Marian [Laboratory of Plants Ecological Physiology, Institute of Systems Biology and Ecology AS CR, Prague Czech Republic; Montagnani, Leonardo [Forest Services, Autonomous Province of Bolzano, Bolzano Italy; Faculty of Sciences and Technology, Free University of Bolzano, Bolzano Italy; Wohlfahrt, Georg [Institute for Ecology, University of Innsbruck, Innsbruck Austria; European Academy of Bolzano, Bolzano Italy; D' Odorico, Petra [Grassland Sciences Group, Institute of Agricultural Sciences, ETH Zurich Switzerland; Cook, David [Atmospheric and Climate Research Program, Environmental Science Division, Argonne National Laboratory, Argonne Illinois USA; Arain, M. Altaf [McMaster Centre for Climate Change and School of Geography and Earth Sciences, McMaster University, Hamilton Ontario Canada; Bonal, Damien [INRA Nancy, UMR EEF, Champenoux France; Beringer, Jason [School of Earth and Environment, The University of Western Australia, Crawley Australia; Blanken, Peter D. [Department of Geography, University of Colorado Boulder, Boulder Colorado USA; Loubet, Benjamin [UMR ECOSYS, INRA, AgroParisTech, Université Paris-Saclay, Thiverval-Grignon France; Leclerc, Monique Y. [Department of Crop and Soil Sciences, College of Agricultural and Environmental Sciences, University of Georgia, Athens Georgia USA; Matteucci, Giorgio [Viea San Camillo Ed LellisViterbo, University of Tuscia, Viterbo Italy; Nagy, Zoltan [MTA-SZIE Plant Ecology Research Group, Szent Istvan University, Godollo Hungary; Olejnik, Janusz [Meteorology Department, Poznan University of Life Sciences, Poznan Poland; Department of Matter and Energy Fluxes, Global Change Research Center, Brno Czech Republic; Paw U, Kyaw Tha [Department of Land, Air and Water Resources, University of California, Davis California USA; Joint Program on the Science and Policy of Global Change, Massachusetts Institute of Technology, Cambridge USA; Varlagin, Andrej [A.N. Severtsov Institute of Ecology and Evolution, Russian Academy of Sciences, Moscow Russia

    2016-04-06

    Light use efficiency (LUE) models are widely used to simulate gross primary production (GPP). However, the treatment of the plant canopy as a big leaf by these models can introduce large uncertainties in simulated GPP. Recently, a two-leaf light use efficiency (TL-LUE) model was developed to simulate GPP separately for sunlit and shaded leaves and has been shown to outperform the big-leaf MOD17 model at 6 FLUX sites in China. In this study we investigated the performance of the TL-LUE model for a wider range of biomes. For this we optimized the parameters and tested the TL-LUE model using data from 98 FLUXNET sites which are distributed across the globe. The results showed that the TL-LUE model performed in general better than the MOD17 model in simulating 8-day GPP. Optimized maximum light use efficiency of shaded leaves (εmsh) was 2.63 to 4.59 times that of sunlit leaves (εmsu). Generally, the relationships of εmsh and εmsu with εmax were well described by linear equations, indicating the existence of general patterns across biomes. GPP simulated by the TL-LUE model was much less sensitive to biases in the photosynthetically active radiation (PAR) input than the MOD17 model. The results of this study suggest that the proposed TL-LUE model has the potential for simulating regional and global GPP of terrestrial ecosystems and it is more robust with regard to usual biases in input data than existing approaches which neglect the bi-modal within-canopy distribution of PAR.

  11. Electronic band structure study of colossal magnetoresistance in Tl 2Mn 2O 7

    Science.gov (United States)

    Seo, D.-K.; Whangbo, M.-H.; Subramanian, M. A.

    1997-02-01

    The electronic structure of Tl 2Mn 2O 7 was examined by performing tight binding band calculations. The overlap between the Mn t 2g- and Tl 6 s-block bands results in a partial filling of the Tl 6 s-block bands. The associated Fermi surface consists of 12 cigar-shape electron pockets with each electron pocket about {1}/{1000} of the first Brillouin zone in size. The Tl 6 s-block bands have orbital contributions from the Mn atoms, and the carrier density is very low. These are important for the occurrence of a colossal magnetoresistance in Tl 2Mn 2O 7.

  12. Myocardial uptake of iodinated free fatty acids and 201Tl in experimental ischemia

    International Nuclear Information System (INIS)

    Westera, G.; Wall, E.E. van der; Visser, F.C.; Scholtalbers, A.S.; Eenige, M.J. van; Roos, J.P.

    1984-01-01

    In an experimental study, we evaluated the uptake of ( 131 I)-17-iodo heptadecanoic acid ( 131 I-HDA), ( 125 I)-15-4 (4-iodophenyl) pentadecanoic acid ( 125 I-PPA) and thallium-201 ( 201 Tl) in the dog heart. Twenty dogs were studied and divided into 3 groups: in group A, 10 dogs (4 normal, 6 with coronary artery occlusion) were studied with 131 I-HDA and 201 Tl; in group B, 5 dogs (with occlusion) received 125 I-PPA and 201 Tl; and in group C, 5 dogs (with occlusion) were studied with 125 I-PPA and 131 I-HDA. Two min after administration of the compounds the hearts were excised and stored in formaldehyde. After sectioning of the left ventricle, total uptake was counted and expressed in percentage of injected dose. Uptake in the normal myocardium (group A) was 4.2+-0.6% for 131 I-HDA and 4.6+-0.7% for 201 Tl; in the occluded dog hearts (group A) we measured values of 2.6+-0.4% for 131 I-HDA (p 201 Tl (p 131 I-HDA, 125 I-PPA and 201 Tl in groups B and C was not significantly different: group B, 125 I-PPA 2.8+-0.8% and 201 Tl 2.5+-0.5%; group C, 125 I-PPA 1.9+-0.7% and 131 I-HDA 1.6+-0.6%. Moreover, regional distribution of both iodinated fatty acids was quite comparable with the distribution of 201 Tl. We conclude that 131 I-HDA and 125 I-PPA show similar uptake as 201 Tl and are distributed according to coronary artery perfusion, which underscores their value as myocardial imaging agents. (orig.) [de

  13. Thermoluminescence characteristics of different dimensions of Ge-doped optical fibers in radiation dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Begum, M.; Mizanur R, A. K. M.; Abdul R, H. A.; Yusoff, Z. [Multimedia University, Faculty of Engineering, 63100 Cyberjaya, Selangor Darul Ehsan (Malaysia); Begum, M. [Bangladesh Atomic Energy Commission, E-12/A, Agargaon, Sher-e-Blanga Nagar Dhaka-1207 (Bangladesh); Mat-Sharif, K. A. [Lingkaran Teknokrat Timur, Telekom Research and Development, 63000 Cyberjaya, Selangor Darul Ehsan (Malaysia); Amin, Y. M. [University of Malaya, Faculty of Science, Depatment of Physics, 50603 Kuala Lumpur (Malaysia); Bradley, D. A., E-mail: go2munmun@yahoo.com [University of Surrey, Department of Physics, Guildford GU2 7XH (United Kingdom)

    2014-08-15

    Important thermoluminescence (Tl) properties of five (5) different core sizes Ge doped optical fibers have been studied to develop new Tl material with better response. These are drawn from same preform applying different speed and tension during drawing phase. The results of the investigations are also compared with most commonly used standard TLD-100 chips (LiF:Mg,Ti) and commercial multimode Ge doped optical fiber (Yangtze Optical Fiber, China). Scanning Electron Microscope (Sem) and EDX analysis of the fibers are also performed to map Ge distribution across the deposited region. Standard Gamma radiation source in SSDL (Secondary Standard Dosimetry Lab) was used for irradiation covering dose range from 1 Gy to 10 Gy. The essential dosimetric parameters that have been studied are Tl linearity, reproducibility and fading. Prior to irradiation all samples ∼0.5 cm length are annealed at temperature of 400 grades C for 1 hour period to standardize their sensitivities and background. Standard TLD-100 chips are also annealed for 1 hour at 400 grades C and subsequently 2 hours at 100 grades C to yield the highest sensitivity. Tl responses of these fibers show linearity over a wide gamma radiation dose that is an important property for radiation dosimetry. Among all fibers used in this study, 100 μm core diameter fiber provides highest response that is 2.6 times than that of smallest core (20 μm core) optical fiber. These fiber-samples demonstrate better response than commercial multi-mode optical fiber and also provide low degree of fading about 20% over a period of fifteen days for gamma radiation. Effective atomic number (Z{sub eff}) is found in the range (13.25 to 13.69) that is higher than soft tissue (7.5) however within the range of human-bone (11.6-13.8). All the fibers can also be re-used several times as a detector after annealing. Tl properties of the Ge-doped optical fibers indicate promising applications in ionizing radiation dosimetry. (author)

  14. Thermoluminescence characteristics of different dimensions of Ge-doped optical fibers in radiation dosimetry

    International Nuclear Information System (INIS)

    Begum, M.; Mizanur R, A. K. M.; Abdul R, H. A.; Yusoff, Z.; Begum, M.; Mat-Sharif, K. A.; Amin, Y. M.; Bradley, D. A.

    2014-08-01

    Important thermoluminescence (Tl) properties of five (5) different core sizes Ge doped optical fibers have been studied to develop new Tl material with better response. These are drawn from same preform applying different speed and tension during drawing phase. The results of the investigations are also compared with most commonly used standard TLD-100 chips (LiF:Mg,Ti) and commercial multimode Ge doped optical fiber (Yangtze Optical Fiber, China). Scanning Electron Microscope (Sem) and EDX analysis of the fibers are also performed to map Ge distribution across the deposited region. Standard Gamma radiation source in SSDL (Secondary Standard Dosimetry Lab) was used for irradiation covering dose range from 1 Gy to 10 Gy. The essential dosimetric parameters that have been studied are Tl linearity, reproducibility and fading. Prior to irradiation all samples ∼0.5 cm length are annealed at temperature of 400 grades C for 1 hour period to standardize their sensitivities and background. Standard TLD-100 chips are also annealed for 1 hour at 400 grades C and subsequently 2 hours at 100 grades C to yield the highest sensitivity. Tl responses of these fibers show linearity over a wide gamma radiation dose that is an important property for radiation dosimetry. Among all fibers used in this study, 100 μm core diameter fiber provides highest response that is 2.6 times than that of smallest core (20 μm core) optical fiber. These fiber-samples demonstrate better response than commercial multi-mode optical fiber and also provide low degree of fading about 20% over a period of fifteen days for gamma radiation. Effective atomic number (Z eff ) is found in the range (13.25 to 13.69) that is higher than soft tissue (7.5) however within the range of human-bone (11.6-13.8). All the fibers can also be re-used several times as a detector after annealing. Tl properties of the Ge-doped optical fibers indicate promising applications in ionizing radiation dosimetry. (author)

  15. Coronary spasm: 201Tl scintiscanning following pharmacological provocation

    International Nuclear Information System (INIS)

    Montz, R.; Mathey, D.; Bleifeld, W.; Hamburg Univ.

    1981-01-01

    According to the authors' experience so far, 201 Tl myocardial scintiscanning is a sufficiently sensitive non-invasive method for detection of coronary vasospasm provoked by ergotamine administration. Mild incomplete and asymptotic forms of coronary vasospasm were detected by scintiscanning. Indications for myocardial scintiscanning of ergotamine-provoked vasospasm are: Cases of angina pectoris at rest in which electrocardiograms during spasm are not available; elleviated symptoms after nitroglycerine administration; exercise electrocardiograms without any sign of ischaemia; negative results of exercise 201 Tl myocardial scintiscanning. (orig.) [de

  16. Thermoluminescence (TL) in the identification of irradiated food

    International Nuclear Information System (INIS)

    Luthra, J.M.

    1992-01-01

    Due to progressive expansion of commercial food irradiation in recent years, the interest in detecting whether a food has been irradiated or not is growing fast and research in several methods for identification of various irradiated food stuffs is the order of the day. TL has emerged as one of the most promising tool for distinguishing between irradiated and unirradiated food. Advantages of TL method over other physical methods, its application to various foods, limitation and present state of art are discussed.(author). 9 refs., 3 tabs

  17. Consideraciones sobre la evolución de la respuesta inmunitaria Th2 y sus posibles relaciones con parasitosis y alergia

    Directory of Open Access Journals (Sweden)

    Luis Caraballo

    2012-03-01

    El desarrollo de este equilibrio debió incluir adaptaciones de ambos organismos y la supervivencia del parásito podría ser el resultado de la adquisición de mecanismos supresores de la respuesta defensiva, la selección de los huéspedes con menor intensidad de la respuesta de tipo 2, o ambas. Esto, a su vez, sugiere que aunque las infecciones helmínticas hayan influido en la conformación de la inmunidad de tipo 2, no han sido una fuerza selectiva importante en el caso particular de la respuesta alérgica que, a su vez, está más ligada a una exagerada respuesta Th2/IgE.   DOI: http://dx.doi.org/10.7705/biomedica.v32i1.419

  18. Positive Selection of γδ CTL by TL Antigen Expressed in the Thymus

    Science.gov (United States)

    Tsujimura, Kunio; Takahashi, Toshitada; Morita, Akimichi; Hasegawa-Nishiwaki, Hitomi; Iwase, Shigeru; Obata, Yuichi

    1996-01-01

    To elucidate the function of the mouse TL antigen in the thymus, we have derived two TL transgenic mouse strains by introducing Tla a -3 of A strain origin with its own promoter onto a C3H background with no expression of TL in the thymus. These transgenic mouse strains, both of which express high levels of Tlaa-3-TL antigen in their thymus, were analyzed for their T cell function with emphasis on cytotoxic T lymphocyte (CTL) generation. A T cell response against TL was induced in Tg.Tlaa-3-1, Tg.Tlaa-3-2, and control C3H mice by skin grafts from H-2K b/T3 b transgenic mice, Tg.Con.3-1, expressing T3b-TL ubiquitously. Spleen cells from mice that had rejected the T3b-TL positive skin grafts were restimulated in vitro with Tg.Con.3-1 irradiated spleen cells. In mixed lymphocyte cultures (MLC), approximately 20% and 15% of Thy-1+ T cells derived from Tg.Tlaa-3-1 and Tg.Tlaa-3-2, respectively, expressed TCRγδ, whereas almost all those from C3H expressed TCRαβ. The MLC from Tg.Tlaa-3-2 and C3H demonstrated high CTL activity against TL, while those from Tg.Tlaa-3-1 had little or none. The generation of γδ CTL recognizing TL in Tg.Tlaa-3-2, but not C3H mice, was confirmed by the establishment of CTL clones. A total of 14 γδ CTL clones were established from Tg.Tlaa-3-2, whereas none were obtained from C3H. Of the 14 γδ CTL clones, 8 were CD8+ and 6 were CD4−CD8− double negative. The CTL activity of all these clones was TL specific and inhibited by anti-TL, but not by anti-H-2 antibodies, demonstrating that they recognize TL directly without antigen presentation by H-2. The CTL activity was blocked by antibodies to TCRγδ and CD3, and also by antibodies to CD8α and CD8β in CD8+ clones, showing that the activity was mediated by TCRγδ and coreceptors. The thymic origin of these γδ CTL clones was indicated by the expression of Thy-1 and Ly-1 (CD5), and also CD8αβ heterodimers in CD8+ clones on their surfaces and by the usage of TCR Vγ4 chains in 12 of

  19. Clinical use of /sup 201/Tl myocardial scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Senda, K; Imaeda, T; Kato, T; Asada, S; Doi, H

    1977-04-01

    Myocardial imaging with /sup 201/Tl and scinticamera was studied experimentally using specially designed phantoms and clinically in 23 patients with myocardial infarction or other heart disease. In the phantom experiment, quality of image, accumulative count rate, and detectability of the defect were compared to obtain the best technique for their detection, using four different collimators, i.e., converging, pin-hole, 4000-hole, and 140 keV high-resolution, at two photopeak levels of /sup 201/Tl of 75 and 167 keV, and combining a radiation absorber. In patient examination, myocardial images taken at different periods after injection, different detecting conditions of the scinticamera, and various detecting projections were compared. Images of the converging collimator at the 75 keV photopeak revealed considerably higher accumulative counts and relatively higher quality than those of other detecting conditions. It was necessary to take as many images as possible in various projections, in order to detect the location and size of the myocardial ischemic lesion because the lesion was demonstrated as a clear defect only in profile. It became evident that images taken between about 25 and 90 min delineated the myocardium more clearly than those taken in other periods. Normal images taken in 8 patients without ischemic heart disease appeared in the shape of a doughnut of horseshoe, demonstrating mainly the left venticular myocardium. The image was faint in the region of the aortic or mitral valve and thin in the region of the apical wall. A faint image of the right ventricular myocardium was sometimes seen. In 3 patients with valvular heart disease, findings suggested changes in the thickness of myocardium and the distribution of coronary blood flow. In 11 of 12 patients with old myocardial infarction, the location and size of the lesion was detected.

  20. Study of 207Tl126 Produced in Deep-Inelastic Reactions

    Directory of Open Access Journals (Sweden)

    Wilson E.

    2014-03-01

    Full Text Available Deep-inelastic collisions of a 208Pb beam on a 208Pb target were performed using the ATLAS accelerator at Argonne National Laboratory. The Gammasphere detector array was used for the detection of prompt and delayed gamma-rays of the reaction products.207Tl is one proton away from the 208Pb doubly-magic nucleus. Its low-energy level structure is dominated by the single proton-hole states πs1/2−1, πd3/2−1 and πh11/2−1. The 11/2− state is isomeric with T1/2 = 1.33(11 s. The reaction partner of 207Tl is 209Bi, which has arelatively well established level scheme compared to 207Tl. Cross-coincidences between these two nuclei were used to confirm or establish levels above the 11/2− isomeric state in 207Tl. These states are obtained via breaking of the neutron core. Angular correlation analysis was performed on known transitions in 208Pb, proving the applicability of this method for multipolarity assignment.

  1. Antiferromagnetism Induced in the Vortex Core of Tl2Ba2CuO6++δ Probed by Spatially-Resolved 205Tl-NMR

    International Nuclear Information System (INIS)

    Kumagai, K.; Kakuyanagi, K.; Matsuda, Y.; Hasegawa, T.

    2003-01-01

    Magnetism in the vortex core state has been studied by spatially-resolved NMR. The nuclear spin lattice relaxation rate T 1 -1 of 205 Tl in nearly optimal-doped Tl 2 Ba 2 CuO 6+ δ (T c =85 K) is significantly enhanced in the vortex core region. The NMR results suggest that the suppression of the d-wave superconducting order parameter in the vortex core leads to the nucleation of islands with local antiferromagnetic (AF) order. (author)

  2. Synthesis and properties of Tl endash Ba endash Ca endash Cu endash O superconductors

    International Nuclear Information System (INIS)

    Siegal, M.P.; Venturini, E.L.; Morosin, B.; Aselage, T.L.

    1997-01-01

    We review the synthesis methods and properties of single crystal, powder and thin film TlBaCaCuO high-temperature superconducting (Tl-HTS) materials. With transition temperatures ≥100K for several compounds, Tl-HTS materials present real opportunities for applications above 77 K. Experiments using (1) single crystals: determined precise structural parameters and identified the complex Tl 1+ -Tl 3+ equilibrium model; (2) powders: studied the complex thermodynamic phase diagram; and (3) epitaxial films: have studied fundamental properties such as electron pair symmetry and the effect of controlled extrinsic defects on flux pinning strength, as well as providing the large-area surfaces required for device applications. copyright 1997 Materials Research Society

  3. Novel laser-processed CsI:Tl detector for SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Sabet, H., E-mail: hsabet@mgh.harvard.edu; Uzun-Ozsahin, D.; El-Fakhri, G. [Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts 02129 (United States); Bläckberg, L. [Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts 02129 and Department of Physics and Astronomy, Uppsala University, Uppsala 75120 (Sweden)

    2016-05-15

    Purpose: The aim of this work is to demonstrate the feasibility of a novel technique for fabrication of high spatial resolution CsI:Tl scintillation detectors for single photon emission computed tomography systems. Methods: The scintillators are fabricated using laser-induced optical barriers technique to create optical microstructures (or optical barriers) inside the CsI:Tl crystal bulk. The laser-processed CsI:Tl crystals are 3, 5, and 10 mm in thickness. In this work, the authors focus on the simplest pattern of optical barriers in that the barriers are created in the crystal bulk to form pixel-like patterns resembling mechanically pixelated scintillators. The monolithic CsI:Tl scintillator samples are fabricated with optical barrier patterns with 1.0 × 1.0 mm{sup 2} and 0.625 × 0.625 mm{sup 2} pixels. Experiments were conducted to characterize the fabricated arrays in terms of pixel separation and energy resolution. A 4 × 4 array of multipixel photon counter was used to collect the scintillation light in all the experiments. Results: The process yield for fabricating the CsI:Tl arrays is 100% with processing time under 50 min. From the flood maps of the fabricated detectors exposed to 122 keV gammas, peak-to-valley (P/V) ratios of greater than 2.3 are calculated. The P/V values suggest that regardless of the crystal thickness, the pixels can be resolved. Conclusions: The results suggest that optical barriers can be considered as a robust alternative to mechanically pixelated arrays and can provide high spatial resolution while maintaining the sensitivity in a high-throughput and cost-effective manner.

  4. Novel laser-processed CsI:Tl detector for SPECT

    International Nuclear Information System (INIS)

    Sabet, H.; Uzun-Ozsahin, D.; El-Fakhri, G.; Bläckberg, L.

    2016-01-01

    Purpose: The aim of this work is to demonstrate the feasibility of a novel technique for fabrication of high spatial resolution CsI:Tl scintillation detectors for single photon emission computed tomography systems. Methods: The scintillators are fabricated using laser-induced optical barriers technique to create optical microstructures (or optical barriers) inside the CsI:Tl crystal bulk. The laser-processed CsI:Tl crystals are 3, 5, and 10 mm in thickness. In this work, the authors focus on the simplest pattern of optical barriers in that the barriers are created in the crystal bulk to form pixel-like patterns resembling mechanically pixelated scintillators. The monolithic CsI:Tl scintillator samples are fabricated with optical barrier patterns with 1.0 × 1.0 mm"2 and 0.625 × 0.625 mm"2 pixels. Experiments were conducted to characterize the fabricated arrays in terms of pixel separation and energy resolution. A 4 × 4 array of multipixel photon counter was used to collect the scintillation light in all the experiments. Results: The process yield for fabricating the CsI:Tl arrays is 100% with processing time under 50 min. From the flood maps of the fabricated detectors exposed to 122 keV gammas, peak-to-valley (P/V) ratios of greater than 2.3 are calculated. The P/V values suggest that regardless of the crystal thickness, the pixels can be resolved. Conclusions: The results suggest that optical barriers can be considered as a robust alternative to mechanically pixelated arrays and can provide high spatial resolution while maintaining the sensitivity in a high-throughput and cost-effective manner.

  5. Zeroing of the TL signal of sediment undergoing fluvial transportation: a laboratory experiment

    International Nuclear Information System (INIS)

    Gemmell, A.M.D.

    1985-01-01

    Rates of bleaching of suspended sediment undergoing fluvial transportation in a closed laboratory flume beneath a u.v. lamp were measured. It was found that the speed of zeroing is inversely related to the speed of flow. This is attributed to the effects of flow turbulence in keeping sediment in suspension, thereby reducing the penetration of u.v. radiation, and to the re-entrainment of partially bleached or unbleached sediment into the flow. The time required to reduce TL to the residual levels indicated by sunlamp bleaching experiments are such as to suggest that at faster flows sediments in a heavily-laden stream may never attain a complete bleaching. (author)

  6. Thallium(I copper(I thorium(IV triselenide, TlCuThSe3

    Directory of Open Access Journals (Sweden)

    James A. Ibers

    2012-07-01

    Full Text Available Thallium(I copper(I thorium(IV triselenide, TlCuThSe3, crystallizes with four formula units in the space group Cmcm in the KCuZrS3 structure type. There is one crystallographically independent Th, Tl, and Cu atom at a site of symmetry 2/m.., m2m, and m2m, respectively. There are two crystallographically independent Se atoms at sites of symmetry m.. and m2m. The structure consists of sheets of edge-sharing ThSe6 octahedra and CuSe4 tetrahedra stacked parallel to the (010 face, separated by layers filled with chains of Tl running parallel to [100]. Each Tl is coordinated by a trigonal prism of Se atoms.

  7. Defects that control the properties of Tl- and Hg-based superconductors

    International Nuclear Information System (INIS)

    Jorgensen, J.D.; Chmaissem, O.; Hinks, D.G.; Mitchell, J.F.; Wagner, J.L.; Univ. of North Dakota, Grand Forks, ND; Jensen, W.R.; Dabrowski, B.; Northern Illinois Univ., DeKalb, IL

    1997-03-01

    Defects that affect T c in Tl 2 Ba 2 CuO 6+δ and HgBa 2 CuO 4+δ and HgBa 2 CuO 4+δ have been characterized by neutron powder diffraction. In Tl 2 Ba 2 CuO 6+δ , the dominant defect is interstitial oxygen between the two Tl-O planes, but Cu substitution on the Tl site also affects properties and there is evidence for a second oxygen defect for compositions in the vicinity of maximum T c . In HgBa 2 CuO 4+δ , there are two competing oxygen defects in the Hg layer. The relative concentrations of these defects switches upon passing from the underdoped region, through the maximum T c , to the overdoped region. This remarkable behavior could result from a change in the topology of the Fermi surface upon passing through the van Hove singularity

  8. Pulse shaping for fast coincidence with NaI(Tl) detectors

    International Nuclear Information System (INIS)

    Bose, S.; Sinha, B.K.; Bhattacharya, R.

    1983-01-01

    The effect of multiple limiting of the anode pulses of the photomultiplier tubes on the resolving time of an NaI(Tl)-NaI(Tl) fast coincidence set up is investigated with the help of a simple transistored limiter circuit. The performance of the set up for different energy ranges selected in the side channels is also investigated. (orig.)

  9. Estimating distribution parameters of annual maximum streamflows in Johor, Malaysia using TL-moments approach

    Science.gov (United States)

    Mat Jan, Nur Amalina; Shabri, Ani

    2017-01-01

    TL-moments approach has been used in an analysis to identify the best-fitting distributions to represent the annual series of maximum streamflow data over seven stations in Johor, Malaysia. The TL-moments with different trimming values are used to estimate the parameter of the selected distributions namely: Three-parameter lognormal (LN3) and Pearson Type III (P3) distribution. The main objective of this study is to derive the TL-moments ( t 1,0), t 1 = 1,2,3,4 methods for LN3 and P3 distributions. The performance of TL-moments ( t 1,0), t 1 = 1,2,3,4 was compared with L-moments through Monte Carlo simulation and streamflow data over a station in Johor, Malaysia. The absolute error is used to test the influence of TL-moments methods on estimated probability distribution functions. From the cases in this study, the results show that TL-moments with four trimmed smallest values from the conceptual sample (TL-moments [4, 0]) of LN3 distribution was the most appropriate in most of the stations of the annual maximum streamflow series in Johor, Malaysia.

  10. Preparation of 199Tl using the electroplating gold targets on the internal target installation of cyclotron

    International Nuclear Information System (INIS)

    Zhou Dehai; Xie Degao; Chao Yangshu; Liao Fuquan; Zhang Youfa; Wang Zefu

    1992-01-01

    The separative conditions of 199 Tl from Cu, Au and Ga by reaction 197 Au(α, 2n) 199 Tl on the internal target installation of cyclotron is studied. The α-particle energy is selected in the range of 24-15 MeV. The cumulative current intensities of such α-particle beams bombarding the gold target at 150-200 μA are 1200 μA · h and 1500 μA · h respectively. The radiochemical separation of 199 Tl is carried out with isopropyl ether extraction and anions exchange from the irradiated gold targets. The radioactivities of 199 Tl and 200 Tl are 2.3 x 10 5 Bq and 7.1 x 10 2 Bq, and 200 Tl makes up 0.29% of the total radioactivity. The impurity elements contained 1 ml of 199 TlCl injection solution are Au 199 TlCl has been used in clinical experiments in vivo and relatively good results have been obtained

  11. Coronary collateral circulation during exercise assessed with stress Tl-201 SPECT

    International Nuclear Information System (INIS)

    Tanaka, Takeshi; Aizawa, Tadanori

    1995-01-01

    Stree Tl-201 single photon emission computed tomography (SPECT) was undertaken in 25 patients with complete occlusion of the left anterior descending artery in which the major collateral circulation was septal segment supplied by the right posterior descending artery with no significant occlusion. The ratio of blood flow in ischemic area to that in normal area was quantitatively determined on Tl-201 images, and the degree of ischemia was expressed by Tl uptake ratio. Ischemia was found in 22 of the 25 patients. Of the 22 patients, 9 showed Tl uptake ratio of less than 50%. Tl uptake ratio in the inferior segment was 76.8±10.3%. In 11 patients, it was less than 75%. Redistribution images were acquired in 19 patients. Changes in Tl uptake ratio on the 90 degrees projection of the septum were less than 20%, with a lowest value of 59.1±11.3% in 14 patients; and these were 20% or more, with a lowest value of 45.2±11.1% in 8 patients. When coronary collateral circulation is not supplied by exercise, septal perfusion may be decreased. In cases of complete occlusion of the anteiror descending artery, ischemia may not uniform over the whole ischemic area and may be noticeable around the anterior descending artery. In cases of lesions in the anteior descending artery, however, collateral circulation supplied by the right coronary artery may occur by exercise when ischemia in the anterior segment was severer than in the septal segment. (N.K.)

  12. Investigation of the thermoluminescent response of K2GdF5:Dy3+ crystals to photon radiation and neutron fields

    International Nuclear Information System (INIS)

    Silva, Edna C.; Faria, Luiz O.; Santos, Joelan A.L.; Vilela, Eudice C.

    2009-01-01

    The thermoluminescent (TL) properties of undoped and Dy 3+ doped K 2 GdF 5 crystals were investigated from the point of view of gamma and neutron dosimetry. Crystalline K 2 GdF 5 platelets with thickness of about 1 mm and doped with 0.0, 0.2, 1.0, 5.0 and 10.0 at.% Dy 3+ ions, synthesized under hydrothermal conditions, were irradiated in order to study TL sensitivity, as well as dose and energy response, reproducibility and fading. As it has been turned out, crystals doped with 5.0 at% Dy 3+ show the most efficient TL response and demonstrate a linear response to doses for all the radiation fields. TL glow curves from Dy 3+ doped K 2 GdF 5 crystals can be deconvoluted into four individual TL peaks centered at 153, 185, 216 and 234 deg C. Concerning the photon fields studied, the maximum TL response has been found for the 52.5 keV photons. The intensity is 15 times more than that of the response for the 662 keV photons from a Cs-137 source. On the other hand, the K 2 GdF 5 crystals doped with 5.0 at % Dy 3+ have also been found to have the better TL response for fast neutron radiation, among all dopants studied. For fast neutron radiation produced by a 241 Am-Be source, the TL responses for doses were also linear and comparable to that of commercial TLD-600, irradiated at same conditions. It has been established that the gamma sensitivity of the crystals is about 0.07% of the neutron sensitivity and the fast neutron sensitivity is about 4.5 % of the thermal neutron sensitivity. These results points out that K 2 Gd 0.95 Dy 0.05 F 5 crystals are good candidates for use in neutron dosimetry applications. (author)

  13. Novel interplay between high-Tc superconductivity and antiferromagnetism in Tl-Based Six-CuO2-layered cuprates. 205Tl- and 63Cu-NMR probes

    International Nuclear Information System (INIS)

    Mukuda, Hidekazu; Shiki, Nozomu; Kimoto, Naoki; Yashima, Mitsuharu; Kitaoka, Yoshio; Tokiwa, Kazuyasu; Iyo, Akira

    2016-01-01

    We report 63 Cu- and 205 Tl-NMR studies on six-layered (n = 6) high-T c superconducting (SC) cuprate TlBa 2 Ca 5 Cu 6 O 14+δ (Tl1256) with T c ∼ 100 K, which reveal that antiferromagnetic (AFM) order takes place below T N ∼ 170 K. In this compound, four underdoped inner CuO 2 planes [n(IP) = 4] sandwiched by two outer planes (OPs) are responsible for the onset of AFM order, whereas the nearly optimally-doped OPs responsible for the onset of bulk SC. It is pointed out that an increase in the out-of-plane magnetic interaction within an intra-unit-cell causes T N ∼ 45 K for Tl1245 with n(IP) = 3 to increase to ∼170 K for Tl1256 with n(IP) = 4. It is remarkable that the marked increase in T N and the AFM moments for the IPs does not bring about any reduction in T c , since T c ∼ 100 K is maintained for both compounds with nearly optimally doped OP. We highlight the fact that the SC order for n ≥ 5 is mostly dominated by the long-range in-plane SC correlation even in the multilayered structure, which is insensitive to the magnitude of T N and the AFM moments at the IPs or the AFM interaction among the IPs. These results demonstrate a novel interplay between the SC and AFM orders when the charge imbalance between the IPs and OP is significantly large. (author)

  14. The influence of high doses of radiation in citrine stones

    International Nuclear Information System (INIS)

    Teixeira, M. I.; Caldas, L. V. E.

    2014-08-01

    The possibility of using samples of Brazilian stones as quartz, amethyst, topaz, jasper, etc. for high-dose dosimetry has been studied in recent years at IPEN, using the techniques of optical absorption (Oa), thermoluminescent (Tl), optically stimulated luminescence (OSL) and resonance paramagnetic electron (EPR). In this work, the Tl properties of citrine samples were studied. They were exposed to different doses of gamma radiation ( 60 Co). The natural citrine stone was extracted from a mine in Minas Gerais state, Brazil; it is a tecto silicate ranked as one of three-dimensional structure, showing clear yellow to golden brown color. The natural citrine stone is classified as quartz (SiO 2 ), and it has a lower symmetry and more compact reticulum. The Tl emission curve showed two peaks at 160 grades C and 220 grades C. To remove the Tl peak (160 grades C) of the sintered citrine pellet glow curves, different thermal treatments were tested during several time intervals. The Tl dose-response curve between 50 Gy and 100 kGy, the reproducibility of Tl response and the lower detection dose were obtained. The results show that citrine may be useful as high-dose detectors. (Author)

  15. The influence of high doses of radiation in citrine stones

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, M. I. [Universidade Nove de Julho - UNINOVE, Rua Vergueiro 235/249, 01504-001 Sao Paulo (Brazil); Caldas, L. V. E., E-mail: miteixeira@ipen.br [Instituto de Pesquisas Energeticas e Nucleares / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil)

    2014-08-15

    The possibility of using samples of Brazilian stones as quartz, amethyst, topaz, jasper, etc. for high-dose dosimetry has been studied in recent years at IPEN, using the techniques of optical absorption (Oa), thermoluminescent (Tl), optically stimulated luminescence (OSL) and resonance paramagnetic electron (EPR). In this work, the Tl properties of citrine samples were studied. They were exposed to different doses of gamma radiation ({sup 60}Co). The natural citrine stone was extracted from a mine in Minas Gerais state, Brazil; it is a tecto silicate ranked as one of three-dimensional structure, showing clear yellow to golden brown color. The natural citrine stone is classified as quartz (SiO{sub 2}), and it has a lower symmetry and more compact reticulum. The Tl emission curve showed two peaks at 160 grades C and 220 grades C. To remove the Tl peak (160 grades C) of the sintered citrine pellet glow curves, different thermal treatments were tested during several time intervals. The Tl dose-response curve between 50 Gy and 100 kGy, the reproducibility of Tl response and the lower detection dose were obtained. The results show that citrine may be useful as high-dose detectors. (Author)

  16. Sample dependent correlation between TL and LM-OSL in Al2O3:C

    International Nuclear Information System (INIS)

    Dallas, G.I.; Polymeris, G.S.; Stefanaki, E.C.; Afouxenidis, D.; Tsirliganis, N.C.; Kitis, G.

    2008-01-01

    Al 2 O 3 :C single crystals are known to exhibit different, sample dependent, glow-curve shapes. The relation between the Thermoluminescence (TL) traps and the linear modulated optically stimulation luminescence (LM-OSL) traps is of high importance. In the present work a correlation study is attempted using 23 single crystals with dimensions between 400 and 500μm. The correlation study involved two steps. In the first step, both TL glow curves and LM-OSL decay curves are deconvoluted and a one-to-one correlation between TL peaks and LM-OSL components is attempted. In the second step the TL glow-curves are corrected for thermal quenching, the corrected curves are deconvoluted and a new correlation between TL and LM-OSL individual components is performed

  17. Improving TL dosimetry for external radiotherapy

    International Nuclear Information System (INIS)

    Bustos, S.R.; Velez, G.; Rubio, M.

    1998-01-01

    Full text: In vivo thermoluminescence dosimetry (TLD) has always been one of the most accurate dosimetry method for external radiotherapy control, but the delay in the response is a well know drawback when it is applied. In this work we show some improvements and demonstrate that keeping the precision and accuracy of this technique, it is possible to obtain a response in few hours. Harshaw 4000 TL reader and LiF TLD-100 dosimeters, chips (3,1 x 3,1 x 0,9 mm 3 ) and rods (1 x 1 x 6 mm 3 ) have been used. The thermal treatment necessary to reuse the TLD is only 1h at 400 degree C, by using a glow curve analyser developed at the Ciemat (Spain), that allows a complete, prompt and precise identification of the individuals peaks. The dosimeters are periodically and individually calibrated. We also have study the factors contributing to the relation TL-dose like linearity, energy correction, directional response and fading. All those results are included into an Excel worksheet which automatically give us the dose resulting from the TL reading (peaks areas 4 and 5). The obtained uncertainty is better than 5%. The TLD already irradiated in radiotherapy institutions distant 30-40 Km from our centre can be read and analysed in about 3-4 hours. These facts render our methods rapid and allow a better control of radiotherapy treatment even if it is bi-fractionated. (author) [es

  18. RDM lifetime measurements in 187Tl

    International Nuclear Information System (INIS)

    Chamoli, S.K.; Joshi, P.; Kumar, A.; Govil, I.M.; Mukherjee, G.; Singh, R.P.; Muralithar, S.; Bhowmik, R.K.

    2003-01-01

    The present work is an attempt to study the shape changes in 187 Tl through a measurement of electromagnetic transition probabilities of the high spin states. The Doppler shifted recoil distance technique was used to measure the lifetimes

  19. Concentration dependence of the light yield and energy resolution of NaI:Tl and CsI:Tl crystals excited by gamma, soft X-rays and alpha particles

    CERN Document Server

    Trefilova, L N; Kovaleva, L V; Zaslavsky, B G; Zosim, D I; Bondarenko, S K

    2002-01-01

    Based on the analysis of light yield dependence on activator concentration for NaI:Tl and CsI:Tl excited by gamma-rays, soft X-rays and alpha-particles, an explanation of the effect of energy resolution enhancement with the rise of Tl content has been proposed. Based on the concept regarding the electron track structure, we proposed an alternative explanation of the intrinsic resolution value. The concept does not take into account the non-proportional response to electrons of different energies and is based on the statistic fluctuation of scintillation photon number formed outside and inside the regions of higher ionization density.

  20. Análisis de la competencia científica de alumnado de secundaria: respuestas y justificaciones a ítems de PISA

    Directory of Open Access Journals (Sweden)

    Beatriz Crujeiras Pérez

    2015-01-01

    Full Text Available En este artículo se analiza el desarrollo de la competencia científica de alumnado de secundaria examinando: asus respuestas y justificaciones a ítems de opción de respuesta múltiple utilizados en la evaluación PISA; y b elefecto que tiene la realización de actividades de laboratorio de indagación que abordan los desempeños evaluadosen PISA sobre la adquisición de la competencia.Los participantes son 21 estudiantes de un centro público cursando la materia de Física y Química en 3º y 4º deESO. Se analizan las respuestas escritas a los ítems PISA al principio y al final del estudio a través de una rúbricarelacionada con los niveles de desempeño establecidos en PISA (OCDE, 2008 para las competencias científicasde identificar cuestiones científicas y usar pruebas científicas. Se comparan los resultados obtenidos al inicio y alfinal del estudio en porcentajes de las opciones de respuesta seleccionadas y de las justificaciones a cada opciónde respuesta. Se identifican diferencias en los resultados obtenidos en la selección de opción de respuesta correctay en la justificación de la misma, así como en los resultados y justificaciones al principio y al final del estudio.

  1. On the Constitution of SoTL: Its Domains and Contexts

    Science.gov (United States)

    Booth, S.; Woollacott, L. C.

    2018-01-01

    In this paper, we present an analysis of the Scholarship of Teaching and Learning in Higher Education (SoTL) which contributes to SoTL both as a field of research practice and as a background to professional development in higher education. We analyse and describe the constitution of the field, and in so doing address its nature in the face of the…

  2. Value of dipyridamole stress 201Tl myocardial SPECT in detecting dysfunction of coronary microcirculation

    International Nuclear Information System (INIS)

    Lou Ying; Jiang Jinqi; Xie Wenhui; Yuan Fang; Wang Tong; Yang Yiqing

    2012-01-01

    Objective: To evaluate the value of dipyridamole stress 201 Tl myocardial SPECT in detecting dysfunction of coronary microcirculation. Methods: Forty-eight patients diagnosed with cardiac syndrome X underwent dipyridamole stress 201 Tl myocardial SPECT. Dipyridamole (0.56 mg/kg) was intravenously injected over 4 min followed by 201 Tl (111 MBq) injection at 2 min after dipyridamole administration. Image was acquired at 10 min and 240 min post-injection and co-analyzed by over two experienced doctors in nuclear medicine after three-dimensional reconstruction. The patients with 'reverse redistribution' underwent repeated dipyridamole stress 201 Tl SPECT after medical therapy for 2 weeks. The clinical symptoms and results of the treadmill exercise test pre-and post-therapy were compared. Results: Forty two patients (42/48, 87.50%) showed segmental defects: 'reverse redistribution' on delayed (240 min) 201 Tl images. After medical treatment, 36 cases of the 42 'reverse redistribution' patients had improvement in both clinical symptoms and treadmill exercise test. Post-treatment 201 Tl imaging showed improvement in 45/49 (91.84%) defect segments. Six of the 42 patients had no improvement in clinical symptoms and/or treadmill exercise test. Post-treatment 201 Tl imaging showed no improvement in all the 7 defect segments on the first scan. Conclusion: Dipyridamole stress 201 Tl myocardial SPECT may be valuable in evaluation of impaired coronary microcirculation associated with cardiac syndrome X. (authors)

  3. Radiation carcinogenesis in radiosensitive mutant Scid mice

    International Nuclear Information System (INIS)

    Ogiu, Toshiaki; Ishii-Ohba, Hiroko; Kobayashi, Shigeru; Nishimura, Mayumi; Shimada, Yoshiya; Tsuji, Hideo; Watanabe, Fumiaki; Suzuki, Fumio; Sado, Toshihiko

    2000-01-01

    The Scid mice were established as a severe combined immunodeficient mouse strain lacking both T- and B-cell functions. Scid (homozygote), its parent strain C.B-17 (wild-type) and their hybrid F1 (heterozygote) were used for analysis of the relationship between sensitivity to acute effects of ionizing radiation and radiation-tumor development. Acute effects were studied using γ-rays and LD 50(30) was found to be 4.05 Gy in Scid, 6.5 Gy in F1 and 7.2 Gy in C.B-17. When bone marrow cells were irradiated with X-rays in vitro, survival curves of C.B-17 and F1 cells showed a region of shoulder with D 0 =0.68 and 0.67 Gy, respectively, while those of Scid were of no shoulder with D 0 =0.46 Gy. Scid mice died due to tumors (most were thymic lymphoma, T/L) 20-40 weeks after irradiation with 1-3 Gy γ-rays but C.B-17 and F1 survived longer. Bone marrow transplantation was found effective to prevent the radiation T/L. FACS analysis for surface antigens of those T/L cells suggested the change of Ras oncogenes. The change of Notch 1 gene was suggested by Southern hybridization and thus a possible role of defective DNA-PK in mice alone (not in rats and humans) was suggested as well. (K.H.)

  4. High-pressure single-crystal X-ray diffraction of Tl2SeO4

    International Nuclear Information System (INIS)

    Grzechnik, Andrzej; Breczewski, Tomasz; Friese, Karen

    2008-01-01

    The effect of pressure on the crystal structure of thallium selenate (Tl 2 SeO 4 ) (Pmcn, Z=4), containing the Tl + cations with electron lone pairs, has been studied with single-crystal X-ray diffraction in a diamond anvil cell up to 3.64 GPa at room temperature. No phase transition has been observed. The compressibility data are fitted by a Murnaghan equation of state with the zero-pressure bulk modulus B 0 =29(1) GPa and the unit-cell volume at ambient pressure V 0 =529.6(8) A 3 (B'=4.00). Tl 2 SeO 4 is the least compressible in the c direction, while the pressure-induced changes of the a and b lattice parameters are quite similar. These observations can be explained by different pressure effects on the nine- and 11-fold coordination polyhedra around the two non-equivalent Tl atoms. The SeO 4 2- tetrahedra are not rigid units and become more distorted. Their contribution to the compressibility is small. The effect of pressure on the isotypical oxide materials A 2 TO 4 with the β-K 2 SO 4 structure is discussed. It appears that the presence of electron lone pairs on the Tl + cation does not seem to influence the compressibility of Tl 2 SeO 4 . - Graphical abstract: Pressure dependence of normalized lattice parameters and unit-cell volumes in Tl 2 SeO 4 (Pmcn, Z=4). The solid line is the Murnaghan equation of state

  5. Gamma radiation induced sensitization and photo-transfer in Mg2SiO4:Tb TLD phosphor

    International Nuclear Information System (INIS)

    Lakshmanan, A.R.; Vohra, K.G.

    1979-01-01

    Mg 2 SiO 4 :Tb TLD phosphor was found to show enhanced TL sensitivity to both gamma and UV radiations after high pre-gamma exposures (>100 R) and a post-annealing treatment at 300 0 C for 1 h. Maximum sensitization factors of 2.8 and 55 were obtained at the pre-expsoure levels of 5.2x10 1 C/kg and 1.3x10 3 C/kg for gamma and UV test radiations respectively. The near constancy of the intensity of the residual TL (RTL) peak at 500 0 C for the sensitized sample with increasing test-gamma exposures has ruled out the re-trapping model proposed earlier for the gamma radiation induced sensitization in this phosphor. The Tsub(max) for the sensitized phosphor was found to occur at a higher temperature compared to that for the virgin phosphor. The dependence of sensitization on RTL was explained qualitatively on the basis of competition between sensitization traps (having higher energy than the dosimetry traps) and RTL traps while capturing the charge carriers generated during the test-gamma exposure. The sensitization observed in this phosphor to UV test radiation was found to be a consequence of the photo-transfer of charge carriers from deep (RTL) traps to the shallow (dosimetry) traps. The reduction in RTL peak (500 0 C) intensity of the sensitized sample with increasing test-UV exposure has demonstrated the photo-transfer mechanism in this phosphor. The TL response of the virgin Mg 2 SiO 4 :Tb phosphor was found to be supralinear to both gamma and UV radiations. The TL response of the sensitized phosphor was found to be linear to gamma radiation and sublinear to UV radiation. (Auth.)

  6. Photoluminescence and absorption spectra of various common TL phosphors - interpretation of TL mechanisms

    International Nuclear Information System (INIS)

    Nagpal, J.S.

    1980-01-01

    Photoluminescence and absorption spectra of TL phosphors TLD-100, CaF 2 :Dy, CaSO 4 :Dy(0.05%wt), CaSO 4 :Tm(0.05%wt) and Mg 2 SiO 4 :Tb have been measured. The absorption spectra are typical of RE 2+ in rare earth doped irradiated phosphors. On heating RE 2+ yields RE 3+ and emission from the excited states of RE 3+ is observed. (author)

  7. Mechanisms of TL for production of the 230 {sup o}C peak in natural sodalite

    Energy Technology Data Exchange (ETDEWEB)

    Cano, Nilo F., E-mail: nilocano@dfn.if.usp.b [Institute of Physics, University of Sao Paulo, Rua do Matao, Travessa R, 187, CEP 05508-090, Sao Paulo (Brazil); Professional School of Physics, University of San Agustin of Arequipa, Av. Independencia S/N, Arequipa (Peru); Blak, Ana R. [Institute of Physics, University of Sao Paulo, Rua do Matao, Travessa R, 187, CEP 05508-090, Sao Paulo (Brazil); Ayala-Arenas, Jorge S. [Professional School of Physics, University of San Agustin of Arequipa, Av. Independencia S/N, Arequipa (Peru); Watanabe, Shigueo [Institute of Physics, University of Sao Paulo, Rua do Matao, Travessa R, 187, CEP 05508-090, Sao Paulo (Brazil)

    2011-02-15

    The thermoluminescence (TL) peak in natural sodalite near 230 {sup o}C, which appears only after submitted to thermal treatments and to gamma irradiation, has been studied in parallel with electron paramagnetic resonance (EPR) spectrum appearing under the same procedure. This study revealed a full correlation between the 230 {sup o}C TL peak and the eleven hyperfine lines from EPR spectrum. In both case, the centers disappear at the same temperature and are restored after gamma irradiation. A complete model for the 230 {sup o}C TL peak is presented and discussed. In addition to the correlation and TL model, specific characteristics of the TL peaks are described.

  8. An analysis of annual maximum streamflows in Terengganu, Malaysia using TL-moments approach

    Science.gov (United States)

    Ahmad, Ummi Nadiah; Shabri, Ani; Zakaria, Zahrahtul Amani

    2013-02-01

    TL-moments approach has been used in an analysis to determine the best-fitting distributions to represent the annual series of maximum streamflow data over 12 stations in Terengganu, Malaysia. The TL-moments with different trimming values are used to estimate the parameter of the selected distributions namely: generalized pareto (GPA), generalized logistic, and generalized extreme value distribution. The influence of TL-moments on estimated probability distribution functions are examined by evaluating the relative root mean square error and relative bias of quantile estimates through Monte Carlo simulations. The boxplot is used to show the location of the median and the dispersion of the data, which helps in reaching the decisive conclusions. For most of the cases, the results show that TL-moments with one smallest value was trimmed from the conceptual sample (TL-moments (1,0)), of GPA distribution was the most appropriate in majority of the stations for describing the annual maximum streamflow series in Terengganu, Malaysia.

  9. Effects of smoking on lung uptake of 201Tl during exercise myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Ouyang Wei; He Guorong; Liu Jinhua

    2004-01-01

    Objective: To investigate the influence of smoking on lung uptake of 201 Tl during myocardial perfusion imaging. Methods: Ninety-two healthy subjects, with normal 201 Tl myocardial perfusion imaging findings but no evidence of left ventricular hypertrophy and pulmonary disease, were divided into three groups, smoker, nonsmoker and quitted smoker groups. Exercise/delay 201 Tl myocardial perfusion imaging was performed on all subjects included. Lung/heart ratio was defined on the anterior planar image obtained during exercise tomography. Results: Both the lung/heart ratios during exercise in smoker (0.40 ± 0.07, F=10.635, P 201 Tl lung/heart ratios in smokers are higher than in nonsmokers and this must be kept in mind when 201 Tl lung/heart ratios are used clinically, even in quitted smokers

  10. The model of recombination process in TlBr

    International Nuclear Information System (INIS)

    Grigorjeva, L.; Millers, D.

    2002-01-01

    The time-resolved luminescence was used as a tool in the study of recombination process in several undoped TlBr crystals. The spectra and decay kinetics observed under electron beam excitation were investigated. Observation of several luminescence bands with different decay rates shows that more than one recombination center is involved and the recombination process is quite complicated. The band at ∼2.5 eV is dominant under 10 ns excitation pulse (electron beam or nitrogen laser pulses). The results of short-lived absorption and luminescence are used for analysis of possible mechanisms of recombination processes in TlBr

  11. Development of a sealed source radiation detector system for gamma ray scanning of petroleum distillation columns

    International Nuclear Information System (INIS)

    Vasquez Salvador, Pablo Antonio

    2004-01-01

    Gamma Ray Scanning is an online technique to 'view' the hydraulic performance of an operating column, with no disruption to operating processes conditions (pressure and temperature), as a cost-effective solution. The principle of this methodology consists of a small suitably sealed gamma radiation source and a radiation detector experimentally positioned to the column, moving concurrently in small increments on opposite sides and the quantity of gamma transmitted. The source-detector system consists of: a sealed ''6 0 Co radioactive source in a panoramic lead radiator, a scintillator detector coupled to a ratemeter / analyzer and a mobile system. In this work, a gamma scanning sealed source-detector system for distillation columns, was developed, comparing two scintillator detectors: NaI(Tl) (commercial) and CsI(Tl) (IPEN). In order to project the system, a simulated model of a tray-type distillation column was used. The equipment developed was tested in an industrial column for water treatment (6.5 m diameter and 40 m height). The required activities of 6 ''0Co, laboratory (11.1 MBq) and industrial works (1.48 TBq) were calculated by simulation software. Both, the NaI(Tl) and the CsI(Tl) detectors showed good proprieties for gamma scanning applications, determining the position and presence or absence of trays. (author)

  12. Clinical evaluation of the Tl-201 ECG-gated myocardial SPECT

    International Nuclear Information System (INIS)

    Mochizuki, Teruhito

    1989-01-01

    In order to evaluate the clinical usefulness of the Tl-201 ECG-gated myocardial single photon emission computed tomography (SPECT), we compared the wall motion and the grade of the Tl-201 uptake of the ECG-gated myocardial SPECT with the wall motion of the ECG-gated blood pool SPECT. Materials were 87 patients of 50 old myocardial infarctions (OMIs), 19 hypertrophic cardiomyopathies (HCMs), 2 dilated cardiomyopathies (DCMs) and 16 others. After intravenous injection of 111-185 MBq (3-5 mCi) of Tl-201 at rest, the projection data were acquired using a rotating gamma-camera through 180deg, from RAO 45deg in 24 directions, each of which consisted of 80-100 beats. For the reconstruction of ED, ES and non-gated images, R-R interval was divided into about 20 (18-22) fractions. In 348 regions of interest (anterior, septal, lateral and inferior wall) in 87 cases, wall motion and the Tl-201 uptake were evaluated to three grades (normal, hypokinesis and akinesis; normal, low and defect, respectively), which were compared with the wall motion of the ECG-gated blood pool SPECT. The wall motion and the grade of the Tl-201 uptake of the ECG-gated myocardial SPECT correlated well with the wall motion of the ECG-gated blood pool SPECT (96.6% and 87.9%, respectively). In conclusion, the ECG-gated myocardial SPECT can provide clear perfusion images and is a very useful diagnostic strategy to evaluate the regional wall motion and perfusion simultaneously. (author)

  13. Development of NaI(Tl) scintillating films for imaging soft x-rays

    International Nuclear Information System (INIS)

    Shepherd, J.A.

    1993-01-01

    Thin film NaI(Tl) scintillators, of areas of up to 130 cm 2 , have been fabricated and characterized for use on soft x-ray imaging photomultiplier tubes. Relevant parameters of photon-counting imaging detectors are defined and used to predict the performance of several materials, including CsI(Na), CsI(Tl), CaF 2 (Eu), Lu 2 (SiO 4 )O:Ce, and NaI(Tl), as thin film scintillators on fiber optic substrates. Also, x-ray imaging methodologies are compared. The NaI(Tl) films were vapor-deposited onto quartz and fiber optic substrates using a powder flash deposition technique. When compared to single crystal NaI(Tl), the films were found to have equally high light yield but lower energy resolution. Light yield optimization was studied in detail including the effects of substrate temperature, activator concentration in the evaporant, and boat temperature. Spatial resolution as well as parallax errors are discussed and measured for film thicknesses up to 61 μm. A technique is described that can substantially increase the light collection of high index films on fiber optic disks. The light collection was improved by 20% by coating the disk with potassium silicate before the NaI(Tl) deposition. Large area films, up to 130 cm 2 , had a spatial uniformity of response within ±1.5% for count rate and ±3.5% for light yield, and their spatial resolution exceeded 16.6 lp mm -1 when deposited onto fiber optic substrates. The 8-keV x-ray detection efficiency of the microchannel plate imaging photomultiplier tube coupled to a NaI(Tl) film scintillator is predicted to be 88%. Other uses for the films are also described

  14. Minimising the Spurious TL of Recently Fired Ceramics Using the Foil Technique

    International Nuclear Information System (INIS)

    Michael, C.T.; Zacharias, N.; Polikreti, K.; Pagonis, V.

    1999-01-01

    The new foil technique for measuring the natural dose in TL dating is briefly presented. In this technique very thin samples are made with the necessary plasticity to achieve the best heating contact between sample and heater plate. Measurements can then be made in vacuum and it is possible to use higher heating rates. The effect of the increase of the TL signal with the increase of the heating rate is presented. The foil technique reduces chemiluminescence and increases the TL signal. This allows the application of TL dating to be extended to lower limits (lower ages). These limits are determined by estimating quantitatively the effects of the sample preparation procedure on the induction of spurious TL (triboluminescence). Samples from a two year old ceramic vase were prepared with two different powder preparation procedures: (a) by using a hand drill with a common steel edge and (b) by crushing a piece using a vice. Measurements at a heating rate of 50 deg. C.s -1 were made. The two estimates of P (total dose) provide an estimate of age for each procedure. The age estimation for the vice prepared sample is about 30 years and for the drilled sample is higher than 120 years. It is suggested that the use of a drill for powder preparation be avoided, especially in TL dating and authenticity tests of recently fired ceramics (less than 500 years). (author)

  15. Construction of TSL lector equipment with spectral resolution for the determination of thermally stimulated luminescence (TSL) properties of NaCl: Tl+ induced by UV-visible radiation

    International Nuclear Information System (INIS)

    Alvarez Romero, J.T.

    1993-01-01

    A revision of physical models of thermally stimulated luminescence (TSL) in crystals induced by both ionizing and non-ionizing radiation is presented. Particular emphasis is given to the connection of TSL with other thermally stimulated processes and physico-chemical phenomena because basic information on physical mechanics for TSL can be obtained through them. Glow curves of TSL induced by UV-visible radiation in NaCl: Tl + were measured. Additionally, the following spectrums were obtained for the same samples: optical absorption, excitation, fluorescent emission, and TSL emission. An optical absorption peak was correlated with the Thallium ion concentration. With respect to the TSL emission spectrums, some peaks associated to Thallium dimmers were at 298 and at 480 nm; others which were attributed to NaCl intrinsic properties were at 365, 430, 450 and 525 nm. Also TSL glow curves were studied as a function of the Thallium ion concentration (0.8 ppm to 14.8 ppm). They were de convoluted so as to calculate the activation energy, the frequency factor and the kinetic order for each separate TSL peak. Anomalous values were observed for some frequency factors. A method and TSL lector equipment to obtain TSL emission spectra were developed. (Author)

  16. Portable in situ NaI(Tl) γ spectroscopy system

    International Nuclear Information System (INIS)

    Wang Bairong; Dong Binjiang; Zeng Liping; Shen Tingyun

    2000-01-01

    The author describes a portable in situ NaI(Tl) γ spectroscopy system, which consists of a NaI (Tl) scintillation detector, an integrative spectroscopy card, a notebook computer and spectroscopy software. The spectrometer addresses applications in environmental or nuclear accident in situ γ spectroscopy measurements, and gives valid quantitative results of radionuclide concentrations per unit volume (Bq/kg) or unit area (Bq/cm 2 ) in the soil and absorbed dose rate in air at 1 m above ground (Gy/h)

  17. Examination of TL and optical absorption in calcite's mineral

    International Nuclear Information System (INIS)

    Sabikoglu, I.; Can, N.

    2009-01-01

    Calcite which is a form of crystalline of the calcium carbonate composes parent material of chalk stone (limestone) and marble. Calcite which presents in various colors also in our country consists of yellow, blue, transparent and green colors. In this study, green calcite mineral which is taken from the region of Ayvalik, was examined of its thermoluminescence (TL) and optical absorption features in different doses. It has been obtained a large TL peak in 179 degree C and absorption peak in 550 mm.

  18. Investigation of thermoluminescent response of K2YF5:Dy3+ crystals for gamma and X radiation fields

    International Nuclear Information System (INIS)

    Silva, E.C.; Nogueira, M.S.; Faria, L.O.; Khaidukov, N.M.

    2005-01-01

    K 2 YF 5 crystals doped with rare earths have been synthesized with 0 to 100% of Dy 3+ ions optically active ions and an investigation was conducted to test its thermoluminescent (TL) response due to function of Dy 3+ concentration and their response in energy. After being irradiated with gamma and X-rays, it was observed that crystals doped with 1.0% of Dy 3+ feature the best response TL. The main dosimetric peak can be decomposed into three secondary TL peaks, centered in 96.4, 104.9 and 130.7 deg C, respectively, showing a good linearity and reproducibility of the dose measurements. The sensitization process seems to improve response TL and TL peak sensitivity increase to 130, 7 deg C at the expense of TL peak to 104, 9 deg C. The linear coefficient sign TL for K 2 Y 0.09 Dy 0.01 F5 is comparable to that of the dosemeter CaSO 4 : Mn, irradiated with gamma radiation source ( 137 Cs) under the same conditions. Energy dependence measurements show that the answer for X-rays with energy of 41.1 keV is more than 30 times the response to Cs-137, when exposed to the same dose. Due to the main peak in low temperature and the TL high reply to low energy fields, the results reported indicate that the K 2 YF 5 crystals doped with Dy 3+ present great potential for radiation dosimetry in X-rays therapy, clinical dosimetry and also for applications in digital thermoluminescent images

  19. Radiation induced traps of zinc phosphate and phosphide

    International Nuclear Information System (INIS)

    Murali, K.R.; Rao, D.R.

    1980-01-01

    Thermoluminescence (TL) glow curve (TGC) method has been used to study the traps produced by X-irradiation in Zn 3 (PO 4 ) 2 and Zn 3 P 2 . Prominent TL glow peaks were observed at 100 0 and 360 0 C for zinc phosphate while for zinc phosphide only one glow peak at 245 0 C was observed, and in the latter case the TL output was in general quite low compared to zinc phosphate. The TL spectra for both the glow peaks of zinc phosphate indicated emission band in the region around 560 nm, while for zinc phosphide the emission occurred at 575 nm (in the temperature region 200-270 0 C). The low temperature glow peaks below 270 0 C were less stable compared to those above 300 0 C and were completely destroyed when the irradiated samples were stored in darkness for 24 hr at room temperature. Shining by 470 nm light however produced preferential bleaching of the two TL peaks at 100 and 360 0 C with no effect on the 245 0 C glow peak of zinc phosphide. It is concluded that during heat treatment large numbers of Zn-vacancies are formed due to which complexes like Zn-P are produced by irradiation and the TL traps destroyed in a radiative recombination process are related with these complexes. (author)

  20. Brain SPECT with Tl-201 DDC

    International Nuclear Information System (INIS)

    Bruine, J.F. de.

    1988-01-01

    The development, animal and human experiments and the first clinical results of a new blood flow tracer thallium-201 diethyldithiocarbamate (Tl-201 DDC) are discussed for functional brain imaging with single-photon emission computed tomography (SPECT). 325 refs.; 43 figs.; 22 tabs

  1. EPR and TL correlation in some powdered Greek white marbles

    International Nuclear Information System (INIS)

    Baieetto, Vanessa; Villeneuve, Gerard; Guibert, Pierre; Schvoerer, Max

    2000-01-01

    Thermoluminescence of white powdered marble samples, chosen to display different EPR spectra, were studied. Two peaks at 280 deg. C and 360 deg. C can be observed among the TL glow curves while the EPR spectra exhibit two signals: the A signal with g perp =2.0038 and g par =2.0024 due to the SO - 3 centre and the B one with g 1 =2.0005; g 2 =2.0001; g 3 =1.9998 due to mechanical powder reduction (drilling). Owing to heating and simultaneous experiments, a correlation have been established: the 280 deg. C TL peak is associated to the A signal and thus to the SO - 3 centre and the 360 deg. C TL peak is caused by mechanical treatment corresponding to the B EPR signal

  2. EPR and TL correlation in some powdered Greek white marbles.

    Science.gov (United States)

    Baïetto, V; Villeneuve, G; Guibert, P; Schvoerer, M

    2000-02-01

    Thermoluminescence of white powdered marble samples, chosen to display different EPR spectra, were studied. Two peaks at 280 degrees C and 360 degrees C can be observed among the TL glow curves while the EPR spectra exhibit two signals: the A signal with g perpendicular = 2.0038 and g parallel = 2.0024 due to the SO3- centre and the B one with g1 = 2.0005; g2 = 2.0001; g3 = 1.9998 due to mechanical powder reduction (drilling). Owing to heating and simultaneous experiments, a correlation have been established: the 280 degrees C TL peak is associated to the A signal and thus to the SO3- centre and the 360 degrees C TL peak is caused by mechanical treatment corresponding to the B EPR signal.

  3. Microcomputer control of automated TL reader

    International Nuclear Information System (INIS)

    Bjarland, B.

    1980-01-01

    An automatic TL reader has been developed for use within a TLD based personal monitoring service. A 6800 based microcomputer is used for system control, operator communication, calibration and checking of reader operation, and for output of data. The dosimeter identity code is printed in human readable characters on the dosimeter card, and is read by using an optical character recognition unit. The code may include individual sensitivity correction coefficients for the TL chips on the card. The chips are heated with hot nitrogen gas and the thermoluminescence is recorded by a photomultiplier tube circuit, the gain and offset of which are continuously monitored and, when necessary, adjusted, to maintain calibration. The reader may operate in any of seven modes, i.e. reading modes for three types of dosimeters, semiautomatic modes for production of the three types of dosimeters, and a monitor mode. (Auth.)

  4. Pressure-induced transition in Tl2MoO4

    International Nuclear Information System (INIS)

    Machon, Denis; Friese, Karen; Breczewski, Tomasz; Grzechnik, Andrzej

    2010-01-01

    Tl 2 MoO 4 has been studied under high-pressure by X-ray diffraction, Raman spectroscopy, and optical absorption measurements. A first-order phase transition is observed at 3.5±0.5 GPa. The nature (ordered vs. disordered) of the high-pressure phase strongly depends on the local hydrostatic conditions. Optical absorption measurements tend to show that this transition is concomitant with an electronic structure transformation. Prior to the transition, single crystal X-ray diffraction shows that pressure induces interactions between MoO 4 fragments and the Mo coordination number tends to increase. In addition, the stereoactivity of the lone-pair electrons on the three symmetrically independent Tl-sites is not uniform; while for two sites the stereoactivity decreases with increasing pressures for the third site the stereoactivity increases. - Graphical Abstract: (up) Structural evolutions of Tl 2 MoO 4 in the low-pressure phase. (Down) Optical properties of the high-pressure phase as a function of pressure. Display Omitted

  5. Speciation of Tl(III and Tl(I in hair samples by dispersive liquid–liquid microextraction based on solidification of floating organic droplet prior to flame atomic absorption spectrometry determination

    Directory of Open Access Journals (Sweden)

    S.Z. Mohammadi

    2016-11-01

    Full Text Available Dispersive liquid–liquid microextraction based on solidification of floating organic droplet was successfully used as a sample preparation method prior to flame atomic absorption determination of trace amounts of Tl(III and Tl(I in hair samples. In the proposed method, 1-(2-pyridylazo-2-naphthol, 1-dodecanol and ethanol were used as chelating agent, extraction and dispersive solvent, respectively. Several factors that may be affected in the extraction process, such as type and volume of extraction and disperser solvents, pH, salting out effect, ionic strength and extraction time were studied. Under the optimal conditions, linearity was maintained between 6.0 and 900.0 ng mL−1 for Tl(III. The relative standard deviation for seven replicate determinations of 0.2 μg mL−1 Tl(III was 2.5%. The detection limit based on 3Sb for Tl(III in the original solution was 2.1 ng mL−1. The proposed method has been applied for the determination of trace amounts of thallium in hair samples and satisfactory results were obtained.

  6. Fading of the Tl signal in LiF: Mg, Cu, P during a large post irradiation period

    International Nuclear Information System (INIS)

    Gonzalez, P.R.; Azorin, J.; Furetta, C.

    2004-01-01

    In this work the obtained results of the study of the fading of the Tl signal in dosemeters of LiF activated with magnesium, copper and phosphorus (LiF:Mg,Cu,P) are presented. The studied dosemeters were LiF: Mg,Cu,P + Ptfe, developed in the ININ, taking like reference to the commercial dosemeter GR200A of Chinese manufacture. In both cases the Tl curve presents four peaks; in LiF: Mg,Cu,P + Ptfe, the peaks of smaller size appear in 359 K, 389 K and 447 K, the main dosimetric peak appears in 486 K; in GR200A, the peaks of smaller size appear in 360 K, 389 K and 445 K; while the main dosimetric peak appears in 487 K. The highest fading shown by the dosemeters of LiF: Mg,Cu,P + Ptfe, it was of 3.07%, value very below the one recommended for dosimetric purposes. While the commercial dosemeters presented a fading until of 6.23%, surpassing with the recommended values. The observed fading, it corresponds to the lost of the Tl signal of the peaks 1 and 2, since the first one disappears few hours after the irradiation, while the peak 2, it disappears completely after 94 days, the peak 3 remained stable during the six months of study, while the peak 4, it showed a slight increment due to the contribution of the dose of natural environmental radiation. (Author)

  7. 201Tl in myocardial diagnosis: studies on the influence of dipyridamole, dobutamine ergometer exercise and background subtraction on the 201Tl myocadial scintiscam

    International Nuclear Information System (INIS)

    Seiderer, M.

    1979-01-01

    Changes in 201 Tl myocardial scintiscans upon administration of dipyridamole or dobutamine and upon ergometer exercise relative to scintiscans at rest were investigated as well as the influence of myocardial background subtraction on scintiscan quality and information. A total of 90 201 Tl examinations were carried out in 59 patients. 18 patients had no myocardial disease, 30 patients had a coronary disease, 5 patients suffered from cardiomyopathy and 6 from left ventricular hypertrophy. The findings are discussed in detail. (orig.) [de

  8. Phase equilibria in the Tl2MoO4–R2(MoO43–Zr(MoO42 (R = Al, Cr systems: synthesis, structure and properties of new triple molybdates Tl5RZr(MoO46 and TlRZr0.5(MoO43

    Directory of Open Access Journals (Sweden)

    V. G. Grossman

    2017-12-01

    Full Text Available The Tl2MoO4–R2(MoO43–Zr(MoO42 (R = Al, Cr systems were studied in the subsolidus region using X-ray powder diffraction and differential scanning calorimetric (DSC analysis. Quasi-binary joins were revealed, and triangulation was carried out. New ternary molybdates: Tl5RZr(MoO46 (5:1:2 and TlRZr0.5(MoO43 (1:1:1 (R = Al, Cr were prepared. The unit cell parameters for the new compounds were calculated.

  9. Solvent extraction of Tl(I) with 2-mercaptobenzothiazole into chloroform

    International Nuclear Information System (INIS)

    Itawi, R.K.; Turel, Z.R.

    1984-01-01

    The extraction of Tl(I) with 2-mercaptobenzothiazole into chloroform was studied. The effect of various parameters on the extraction coefficient value was evaluated. The stoichiometry of the extracted species obtained from the substoichiometric extraction was found to be 1:1. This was further supported by the slope ratio method. Decontamination factors of a number of elements in the substoichiometric extraction of Tl(I) were also obtained. (author)

  10. Enhanced thermoelectric figure of merit in strained Tl-doped Bi2Se3

    KAUST Repository

    Saeed, Y.

    2014-07-21

    We explain recent experimental findings on Tl-doped Bi2Se3 by determining the electronic and transport properties by first-principles calculations and semi-classical Boltzmann theory. Though Tl-doping introduces a momentum-dependent spin-orbit splitting, the effective mass of the carriers is essentially not modified, while the band gap is reduced. Tl is found to be exceptional in this respect as other dopants modify the dispersion, which compromises thermoelectricity. Moreover, we demonstrate that only after Tl-doping strain becomes an efficient tool for enhancing the thermoelectric performance. A high figure of merit of 0.86 is obtained for strong p-doping (7 × 10^20 cm^(−3), maximal power factor) at 500 K under 2% tensile strain.

  11. Characterization of nanoporous Al{sub 2}O{sub 3}:C for thermoluminescent radiation dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Barros, V.S.M. de [Departamento de Energia Nuclear-UFPE, Rua prof Luiz Freire, 1000, Recife, PE 50740-540 (Brazil)], E-mail: vdbarros@terra.com.br; Khoury, H.J. [Departamento de Energia Nuclear-UFPE, Rua prof Luiz Freire, 1000, Recife, PE 50740-540 (Brazil); Azevedo, W.M. [Departamento de Quimica Fundamental-CCEN Recife, PE 50740-540 (Brazil); Silva, E.F. da [Departamento de Fisica CCEN Recife, PE 50740-540 (Brazil)

    2007-09-21

    Thermoluminescent (TL) {alpha}-Al{sub 2}O{sub 3}:C dosimeters, produced in the form of single crystals, show a high sensitivity to ionizing radiation (about 40-60 times higher than LiF:Mg,Ti). However, the crystal growth requires high temperatures (2050 deg. C) and highly reducing atmospheres. This paper presents the TL response of thin nanoporous Al{sub 2}O{sub 3}:C membranes obtained by electrochemical anodizing of aluminum in organic acid solutions at room temperature. The TL properties of the samples were analyzed as a function of the anodizing voltage in the interval 30-60 V and of the acid concentrations from 0.05 to 0.6 M. The dosimetric response of the samples for {sup 60}Co gamma radiation is linear with dose, and the best response was found for samples anodized at 130 V with 0.10 M acid concentration.

  12. Anisotropic superconducting state parameters of Tl-2212 superconductors

    International Nuclear Information System (INIS)

    Khaskalam, Amit K.; Singh, R.K.; Varshney, Dinesh

    2001-01-01

    We have estimated the superconducting state parameters and their anisotropy in thallium based superconductors (Tl-2212), in the frame work of Fermi liquid approach. Determination of the effective mass of the charge carriers from the Fermi velocity and estimated anisotropic superconducting state parameters, particularly, the magnetic penetration depth along and perpendicular to the conducting plane. The coherence length along and perpendicular to the ab plane is evaluated and appears to be higher. The temperature dependence of penetration depth, their anisotropy and Ginsburg Landau parameter for optimised doped Tl based cuprates shows the power law. The technique permits a consistency with the reported data. (author)

  13. Variation of Natural Gamma Radiation in Isparta

    International Nuclear Information System (INIS)

    Akkurt, I.

    2004-01-01

    There is always a radiation in the earth, and its level is generated primarily by galactic cosmic rays (GCR), consisting of energetic nuclei of all naturally occurring elements, interacting with atmospheric constituents, through atomic and nuclear collisions. The other sources of natural radiations are global average background radiation from terrestrial sources such as soils, rocks ete. Background radiation levels in the atmosphere vary in intensity with latitude, altitude and phase of the solar cycle. Variation of natural radiation as a function of altitude, geological structure etc has been investigated. The measurements were performed using portable radiation counter which connected to NaI(Tl) probe

  14. Observation of curious spiral growth features in Tl doped Hg bearing ...

    Indian Academy of Sciences (India)

    Synthesis of H(Tl)Ba2Ca2Cu3O8+ superconducting tapes have been accomplished by annealing the precursor tape, Ba2Ca2Cu3O (fabricated by doctor blade tape casting technique) in an environment of H(Tl) vapour. Characterization of superconducting HTSC tape sample was carried out through XRD, TEM, SEM ...

  15. Contabilidad de Costos II. - Capítulo 4. Respuestas

    OpenAIRE

    Morillo Moreno, Marysela C.

    2008-01-01

    ÍNDICE Presentación Orientaciones para el usuario Capítulo 1: Contabilidad de costos por procesos Sistemas de Contabilidad de Costos por Proceso Costos de Producción Conjunta. Productos Principales y Secundarios Capítulo 2: Contabilidad de costos predeterminados Presupuesto Estático y Presupuesto Flexible Sistema de Costos Estándar Capítulo 3: Sistema de costos variables Capítulo 4: Respuestas Bibliografía recomendada Pr...

  16. Centers responsible for the TL peaks of willemite mineral estimated by EPR analysis

    Energy Technology Data Exchange (ETDEWEB)

    Gundu Rao, T.K. [Instituto de Física, Universidade de São Paulo, Rua do Matão, Travessa R, 187, CEP 05508-090, São Paulo, SP (Brazil); Cano, Nilo F., E-mail: nilo.cano@unifesp.br [Departamento de Ciências do Mar, Universidade Federal de São Paulo, Rua Doutor Carvalho de Mendonça, 144, CEP 11070-102, Santos, SP (Brazil); Silva-Carrera, Betzabel N.; Ferreira, Reinaldo M. [Instituto de Física, Universidade de São Paulo, Rua do Matão, Travessa R, 187, CEP 05508-090, São Paulo, SP (Brazil); Javier-Ccallata, Henry S., E-mail: henrysjc@gmail.com [Escuela Profesional de Física, Facultad de Ciencias Naturales y Formales, Universidad Nacional de San Agustín (UNSA), Av. Independencia S/N, Arequipa (Peru); Watanabe, Shigueo, E-mail: watanabe@if.usp.br [Instituto de Física, Universidade de São Paulo, Rua do Matão, Travessa R, 187, CEP 05508-090, São Paulo, SP (Brazil)

    2016-09-15

    The mineral willemite (Zn{sub 2}SiO{sub 4}) exhibits five thermoluminescence (TL) peaks approximately at 160, 225, 260, 310 and 400 °C. Electron paramagnetic resonance (EPR) studies were carried out to study the defect centers induced in the mineral by gamma irradiation and also to identify the centers responsible for the TL process. Room temperature EPR spectrum of irradiated mineral is a superposition of at least four distinct centers. One of the centers (center I) with an isotropic g factor 2.0114 is attributable to an intrinsic O{sup −} type center and the center correlates with the TL peak at 160 °C. Center II exhibiting hyperfine lines is also tentatively assigned to an O{sup −} ion and is related to the low temperature TL peak at 160 °C. Center III is characterized by an axially symmetric g-tensor with principal values g{sub ||}=2.0451 and g{sub ⊥}=2.011 and is identified as an O{sub 2}{sup −} ion. This center appears to be related to 160, 225 and 260 °C TL peaks. Center IV with principal g-values g{sub ||}=2.0025 and g{sub ⊥}=2.0088 is attributed to an F{sup +}-type center (singly ionized oxygen vacancy) and is the likely recombination center for TL peaks between 160 and 310 °C.

  17. Thermoluminescence response of new KClxBr1-x :EuCl3 sintered phosphors exposed to beta and gamma radiation

    International Nuclear Information System (INIS)

    Bernal, R.; Cruz-Zaragoza, E.; Cruz-Vazquez, C.; Burruel-Ibarra, S. E.; Rivera-Flores, M. J.; Barboza-Flores, M.

    2006-01-01

    Alkali halides crystals have been the subject of intense research for an understanding of their radiation-induced defects and luminescence properties. They exhibit noteworthy thermoluminescence (TL) properties when exposed to ionising radiation. Currently, these materials are grown employing expensive and rather complicated techniques. In this work, the results on the TL properties of new alkali halides phosphors fabricated by a simple and inexpensive procedure are presented. The samples were made by mixing KCl, KBr and EuCl 3 salts, and compressing them at a pressure of 3.2 x 10 7 Pa during 3 min, followed by sintering at 700 deg. C during 24 h under air atmosphere. The dosimetric response of the samples showed an increase with radiation dose in the 1.5-20.0 Gy dose range for beta and gamma radiation. The TL glow curves in sintered samples presented significant differences in their peak structures compared with monocrystalline samples, indicating that the nature of the trapping states and the recombination mechanisms may be different. (authors)

  18. EPR and TL correlation in some powdered Greek white marbles

    Energy Technology Data Exchange (ETDEWEB)

    Baieetto, Vanessa E-mail: crpaa@montaigne.u-bordeaux.fr; Villeneuve, Gerard; Guibert, Pierre; Schvoerer, Max

    2000-02-01

    Thermoluminescence of white powdered marble samples, chosen to display different EPR spectra, were studied. Two peaks at 280 deg. C and 360 deg. C can be observed among the TL glow curves while the EPR spectra exhibit two signals: the A signal with g{sub perp}=2.0038 and g{sub par} =2.0024 due to the SO{sup -}{sub 3} centre and the B one with g{sub 1}=2.0005; g{sub 2}=2.0001; g{sub 3}=1.9998 due to mechanical powder reduction (drilling). Owing to heating and simultaneous experiments, a correlation have been established: the 280 deg. C TL peak is associated to the A signal and thus to the SO{sup -}{sub 3} centre and the 360 deg. C TL peak is caused by mechanical treatment corresponding to the B EPR signal.

  19. Pulsed laser deposition of Tl-Ca-Ba-Cu-O films

    International Nuclear Information System (INIS)

    Ianno, N.J.; Liou, S.H.; Woollam, J.A.; Thompson, D.; Johs, B.

    1990-01-01

    Pulsed laser deposition is a technique commonly used to deposit high quality thin films of high temperature superconductors. This paper discusses the results obtained when this technique is applied to the deposition of Tl-Ca-Ba-Cu-O thin films using a frequency doubled Nd:YAG laser operating at 532 nm and an excimer laser operating at 248 nm. Films with onset temperatures of 125 K and zero resistance temperatures of 110 K deposited on (100) oriented MgO from a composite Tl2Ca2Ba2Cu3Ox target were obtained at both wavelengths upon appropriate post deposition annealing. Films deposited at 532 nm exhibit a rough surface, while those deposited at 248 nm are smooth and homogeneous. Upon annealing, films deposited at both wavelengths are single phase Tl2Ca2Ba2Cu3Ox. 12 refs

  20. Electret dosemeter for beta radiation

    International Nuclear Information System (INIS)

    Campos, L.L.; Caldas, L.V.E.; Mascarenhas, S.

    The response characteristics of an electret dosemeter for beta radiation are studied. Experiments were performed using different geometries and walls, and it was verified for which geometry the dosemeter sensitivity is greater. Sources of 90 Sr - 90 Y, 204 Tl and 85 Kr were used in the experiments. (I.C.R.) [pt

  1. Study of carbon-doped micro and nano sized alumina for radiation dosimetry applications

    International Nuclear Information System (INIS)

    Fontainha, C. C. P.; Alves, N.; Ferraz, W. B.; Faria, L. O.

    2017-10-01

    New materials have been widely investigated for ionizing radiation dosimetry for medical procedures. Carbon-doped doped alumina (Al 2 O 3 :C) have been proposed as thermoluminescent and photo luminescent dosimeters. In the present study nano and micro-sized alumina doped with different percentages of carbon, sintered under different atmosphere conditions, at temperatures ranging from 1300 to 1750 degrees Celsius, were sintered and their dosimetric characteristics for gamma fields were investigated. Among the investigated sample preparation methods, the micro-sized alumina doped with 0.01% of carbon and sintered at 1700 degrees Celsius under reducing atmosphere has presented the best Tl output, comparable to the best Tl sensitivities ever reported to alumina and better efficiency than the nano-sized alumina synthesized in this study. The influence of humidity in the Tl signal has been evaluated to be -4.0%. The micro-sized alumina obtained by the methodology used in this work is a suitable candidate for application in X and gamma radiation dosimetry. (Author)

  2. M1 transitions between superdeformed states in 195Tl

    International Nuclear Information System (INIS)

    Zheng Xing; Xingqu Chen; Xiaochun Wang

    1996-01-01

    Using a triaxial-particle-rotor model, the quadrupole and dipole transition energies, kinematic and dynamic moments of inertia, electromagnetic transition probabilities and the relative intensity of the E2 γ-transitions are calculated for superdeformed bands in 195 Tl. A strong perturbation effect of rotation on transition energies and M1 and E2 transitions of superdeformed states is investigated. The total M1 transitions, enhanced by internal conversion, are expected to compete strongly with the E2 γ-ray at low spins in the superdeformed 195 Tl nucleus. (author)

  3. Dopant concentration and thermoluminescence (TL) properties of tailor-made Ge-doped SiO2 fibres

    International Nuclear Information System (INIS)

    Zahaimi, Nurul Arina; Ooi Abdullah, Mohd Haris Ridzuan; Zin, Hafiz; Abdul Rahman, Ahmad Lutfi; Hashim, Suhairul; Saripan, Mohd Iqbal; Paul, Mukul Chandra; Bradley, D.A.; Abdul Rahman, Ahmad Taufek

    2014-01-01

    Study focuses on characterisation of diverse concentrations of Ge-doped SiO 2 fibre as a potential thermoluminescence (TL) system for radiotherapy dosimetry. Irradiations were made using a linear accelerator providing 6 MV and 10 MV photon beams. Investigation has been done on various doped core diameter Ge-doped SiO 2 glass fibres such as commercial telecommunication fibres of 8 µm and 9 µm (CorActive High Tech, Canada), tailor-made fibres of 23 and 50 µm produced by the Central Glass and Ceramic Research Institute Kolkata, and tailor-made fibres of 11 µm produced by the University of Malaya Photonics Research Centre. The fibres have been characterised for TL sensitivity, reproducibility, dose- and energy-dependence. The area under the TL glow curve increases with increasing core diameter. For repeat irradiations at a fixed dose the dosimeter produces a flat response better than 4% (1SD) of the mean of the TL distribution. Minimal TL signal fading was found, less than 0.5% per day post irradiation. Linearity of TL has been observed with a correlation coefficient (r 2 ) of better than 0.980 (at 95% confidence level). For particular dopant concentrations, the least square fits show the change in TL yield, in counts per second per unit mass, obtained from 50 µm core diameter fibres irradiated at 6 MV of photon to be 8 times greater than that of 8 µm core diameter fibre. With respect to energy response, the TL yield at 10 MV decreases by∼5% compared to that at 6 MV, primarily due to the lower mass energy absorption coefficient at higher photon energy. These early results indicate that selectively screened fibres can be developed into a promising TL system, offering high spatial resolution capability and, with this, verification of complex radiotherapy dose distributions. - Highlights: • We examined the TL glow curve intensity for various diameter sizes of germanium doped silica glass fibre. • TL sensitivity increased with the increase of fibre core

  4. Respuesta al entrenamiento en EPOC: Diferencia entre limitación por fatiga muscular y por disnea

    OpenAIRE

    Martín Sívori; Laura Bustamante; Alejandro Martínez Fraga; Marta Almeida; César Saenz

    2011-01-01

    Este estudio comparó la respuesta post entrenamiento al ejercicio en pacientes limitados por fatiga muscular (LF) vs. disnea (LD). Se incluyeron pacientes con EPOC moderada y grave (definición GOLD), clasificándolos en LF si la respuesta a cicloergometría máxima tenía ≥ 2 puntos en la escala de Borg para fatiga muscular vs. disnea; LD a la inversa. Se realizaron ergometría submáxima, 6 minutos y pruebas de calidad de vida mediante cuestionario. Fueron entrenados 3 veces/semana, 90 min/sesión ...

  5. The usefulness of [sup 201]TlCl scintigraphy for the diagnosis of breast tumor

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Tamami; Moriya, Etsuo; Miyamoto, Yukio; Kawakami, Kenji; Kubo, Hirotaka; Uchida, Takeshi [Jikei Univ., Tokyo (Japan). School of Medicine

    1994-06-01

    The usefulness of [sup 201]TlCl SPECT (Tl SPECT) for the diagnosis of breast cancer was evaluated in 14 patients with various breast tumors (9 with invasive ductal carcinoma, 2 with fibroadenoma and 3 with benign process). These tumors ranged in size from 1.5 cm x 1.5 cm to 15.0 cm x 14.0 cm. Tl SPECT was carried out 2 hours after the intravenous injection of [sup 201]TlCl (185 MBq). For quantitative study, ROIs were set in the tumor (T), normal tissue of the opposite breast (B) and myocardium (M). Count ratios of T/B and T/M were calculated. Eight patients with breast cancer and a case of fibroadenoma showed intense accumulation of [sup 201]TlCl in the tumors. The T/B ratio was 1.20[+-]0.68 and the T/M ratio was 0.68[+-]0.31 in the 9 cases. Lymph node metastasis was detected in 2 of 6 cases that were confirmed at operation. No remarkable accumulation of [sup 201]TlCl was seen in 4 patients with benign process. One patient with benign tumor showed a false positive result. The rates of accuracy of mammography and ultrasonography for the same subjects were 82% and 84%, respectively. The results suggest that [sup 201]TlCl SPECT might be useful to assess breast cancer in cases in which the findings of other modalities are equivocal. (author).

  6. Structure and scintillation properties of CsI(Tl) films on Si single crystal substrates

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Lina [State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Information, University of Electronic Science and Technology of China, Chengdu 610054 (China); Liu, Shuang, E-mail: shuangliu@uestc.edu.cn [State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Information, University of Electronic Science and Technology of China, Chengdu 610054 (China); Chen, Dejun; Zhang, Shangjian; Liu, Yong; Zhong, Zhiyong [State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Information, University of Electronic Science and Technology of China, Chengdu 610054 (China); Falco, Charles M. [University of Arizona, College of Optical Sciences, AZ 85721 (United States)

    2016-10-30

    Highlights: • We obtained the desired micro-columnar structure of CsI(Tl) films on the orienting Si substrates. • We improved the micro-columnar structure of CsI(Tl) films under the relatively large deposition rate through using the substrate with a pre-deposited CsI nanolayer. • We modeled the interface structures between the CsI(Tl) films with (200) and (310) orientation and Si(111) substrates to explain the preferred orientation of film under the influence of the orienting substrate significantly. • We gained a new spectrum of the CsI(Tl) films peaked at 740 nm wavelength. - Abstract: CsI(Tl) scintillation films fabricated on glass substrates are widely applied for X-ray imaging because their ability to grow in micro-columnar structure and proper emission wavelength matching CCD cameras. But the coupling process between the CsI(Tl) films and Si-based photo detector would cause coupling loss. In this work, CsI(Tl) films were deposited on the orienting Si substrates and the Si substrates covered by the pre-deposited CsI nanolayers. Structure and scintillation properties of films were examined by using scanning electron microscopy, X-ray diffraction, photoluminescence and radioluminescent spectrum. The films deposited on the orienting Si substrates show the micro-columnar morphology with perfect single crystalline structure and the photoluminescence spectra with bimodal distribution. The performances of the films prepared on the pre-deposited CsI nanolayer, containing micro-columns structure and the light yield are improved.

  7. Structure and scintillation properties of CsI(Tl) films on Si single crystal substrates

    International Nuclear Information System (INIS)

    Guo, Lina; Liu, Shuang; Chen, Dejun; Zhang, Shangjian; Liu, Yong; Zhong, Zhiyong; Falco, Charles M.

    2016-01-01

    Highlights: • We obtained the desired micro-columnar structure of CsI(Tl) films on the orienting Si substrates. • We improved the micro-columnar structure of CsI(Tl) films under the relatively large deposition rate through using the substrate with a pre-deposited CsI nanolayer. • We modeled the interface structures between the CsI(Tl) films with (200) and (310) orientation and Si(111) substrates to explain the preferred orientation of film under the influence of the orienting substrate significantly. • We gained a new spectrum of the CsI(Tl) films peaked at 740 nm wavelength. - Abstract: CsI(Tl) scintillation films fabricated on glass substrates are widely applied for X-ray imaging because their ability to grow in micro-columnar structure and proper emission wavelength matching CCD cameras. But the coupling process between the CsI(Tl) films and Si-based photo detector would cause coupling loss. In this work, CsI(Tl) films were deposited on the orienting Si substrates and the Si substrates covered by the pre-deposited CsI nanolayers. Structure and scintillation properties of films were examined by using scanning electron microscopy, X-ray diffraction, photoluminescence and radioluminescent spectrum. The films deposited on the orienting Si substrates show the micro-columnar morphology with perfect single crystalline structure and the photoluminescence spectra with bimodal distribution. The performances of the films prepared on the pre-deposited CsI nanolayer, containing micro-columns structure and the light yield are improved.

  8. Sources of uncertainty in individual monitoring for photographic,TL and OSL dosimetry techniques

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Max S.; Silva, Everton R.; Mauricio, Claudia L.P., E-mail: max.das.ferreira@gmail.com, E-mail: everton@ird.gov.br, E-mail: claudia@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    The identification of the uncertainty sources and their quantification is essential to the quality of any dosimetric results. If uncertainties are not stated for all dose measurements informed in the monthly dose report to the monitored radiation facilities, they need to be known. This study aims to analyze the influence of different sources of uncertainties associated with photographic, TL and OSL dosimetric techniques, considering the evaluation of occupational doses of whole-body exposure for photons. To identify the sources of uncertainty it was conducted a bibliographic review in specific documents that deal with operational aspects of each technique and the uncertainties associated to each of them. Withal, technical visits to individual monitoring services were conducted to assist in this identification. The sources of uncertainty were categorized and their contributions were expressed in a qualitative way. The process of calibration and traceability are the most important sources of uncertainties, regardless the technique used. For photographic dosimetry, the remaining important uncertainty sources are due to: energy and angular dependence; linearity of response; variations in the films processing. For TL and OSL, the key process for a good performance is respectively the reproducibility of the thermal and optical cycles. For the three techniques, all procedures of the measurement process must be standardized, controlled and reproducible. Further studies can be performed to quantify the contribution of the sources of uncertainty. (author)

  9. Challenges to Disciplinary Knowing and Identity: Experiences of Scholars in a SoTL Development Program

    Science.gov (United States)

    Miller-Young, Janice E.; Yeo, Michelle; Manarin, Karen

    2018-01-01

    Faculty members from five years of an annual Scholarship of Teaching and Learning (SoTL) development program were invited to participate in a study about the impact of SoTL on their teaching, scholarship, and career trajectory. During semi-structured interviews, many expressed feeling discomfort during their journey into SoTL. A qualitative…

  10. Factors which define the α/γ ratio in CsI:Tl crystals

    International Nuclear Information System (INIS)

    Kudin, Alexander M.; Sysoeva, Elena P.; Sysoeva, Elena V.; Trefilova, Larisa N.; Zosim, Dmitry I.

    2005-01-01

    Dependences of light yield and α/γ ratio on the Tl concentration have been studied within a wide range of shaping times. It is shown that the α/γ ratio essentially depends on the Tl concentration. Proper combination of the Tl concentration and optimum shaping time in electronics allows to obtain detectors with rather high light output for γ-rays, α-particles and α/γ ratio values. It has been shown that both the light yield at α-excitation and the α/γ-ratio depend on the time of crystal storage after polishing. On the basis of the idea of the formation of deformation-induced point defects in a thin surface-adjacent layer, the causes of the temporary increasing in light yield for α-particle are explained. An explanation is given of the results obtained by Gwin and Murray concerning the fact that the α/γ ratio is practically independent on Tl concentration

  11. Fiber-optic-coupled dosemeter for remote optical sensing of radiation

    International Nuclear Information System (INIS)

    Justus, B.L.; Huston, A.L.

    1996-01-01

    Remote sensing technologies for the detection and measurement of ionizing radiation exposure are of current interest for applications such as patient dose verification during radiotherapy and the monitoring of environmental contaminants. Fiberoptic-based sensing is attractive due to the advantages of small size, low cost, long life and freedom from electromagnetic interference. Several fiberoptic-based radiation sensing systems have been described that utilize radiation induced changes in the optical characteristics of the fiber such as reduced transmission as a result of darkening of the glass, optical phase shifts due to heating, or changes in the birefringence of a polarization-maintaining fiber. The measurement of radiation induced darkening is limited in both sensitivity and dynamic range and requires long fiber lengths. Phase shift measurements require the use of single-mode lasers, phase sensitive interferometric detection, long fiber lengths and complex signal processing techniques. Alternatively, thermoluminescent (TL) phosphor powders have been coated onto fiberoptic cables and remote dosimetry measurements performed using traditional laser heating techniques. The sensitivity is limited by the requirement for a very thin layer of phosphor material, due to problems associated with light scattering and efficient heating by thermal diffusion. In this paper we report the development of an all-optical, fiber-optic-coupled, thermoluminescence dosemeter for remote radiation sensing that offers significant advantages compared to previous technologies. We recently reported the development of an optically transparent, TL glass material having exceptionally good characteristics for traditional dosimetry applications. We also reported a modified TL glass incorporating a rare earth ion dopant in order to absorb light from a semiconductor laser and utilize the absorbed light energy to internally heat the glass and release the trapped electrons. (author)

  12. Enhanced thermoelectric figure of merit in strained Tl-doped Bi2Se3

    KAUST Repository

    Saeed, Y.; Singh, Nirpendra; Schwingenschlö gl, Udo

    2014-01-01

    We explain recent experimental findings on Tl-doped Bi2Se3 by determining the electronic and transport properties by first-principles calculations and semi-classical Boltzmann theory. Though Tl-doping introduces a momentum-dependent spin

  13. Thermoluminescent dependence with the particle size of polyminerals in food irradiated of Mexican spices; Dependencia Tl con el tamano de particula de poliminerales en alimentos irradiados de especias Mexicanas

    Energy Technology Data Exchange (ETDEWEB)

    Teuffer Z, C. [FQ-UNAM, 04510 Mexico D.F. (Mexico); Cruz Z, E. [ICN-UNAM, A.P. 70-543, 04510 Mexico D.F. (Mexico); Calderon, T. [Depto. de Quimica Agricola-Geologia- Geoquimica, Universidad Autonoma de Madrid, 28049 (Spain); Chernov, V.; Barboza F, M. [CIF, UNISON, A.P. 5-88, Hermosillo, Sonora (Mexico)

    2004-07-01

    The influence of grain size on Tl was analysed in poly minerals extracted from Mexican spices as Origanum vulgare L. (oregano) y Capsicum annun (chile guajillo). The poly minerals size were selected by Zimmerman method up to 10 {mu}m and exposed to 0.5-10 kGy range from {sup 60}Co. The glow curves were centered at 166 C for Capsicum annun and at 126 C for Origanum vulgare l. In both cases was observed at 5 kGy a weak saturation for Tl response. This behaviour is attributed to feldspar and quartz are present in the samples and this results is in agreement with other european spices obtained. For >10 {mu}m particle size the Tl response increased respect to the doses, and it is possible that increase the organic impurities quantities are present in the samples and contributed to the Tl when the samples were thermally excited. The aim of this work is provide more ideas with regard to the behaviour of luminescence emission as dependent of the size particle in the irradiated spices. The methodology might useful for quality control also in radiation processing. (Author)

  14. Dental radiographic units - radiation safety and patient doses

    International Nuclear Information System (INIS)

    Nagpal, J.S.; Varadharajan, Geetha

    2001-01-01

    Three models of dental radiographic machines have been examined for radiation safety. Using TL dosemeters, doses received by the patients at chest level and the gonads have been estimated. Care should be taken to shield gonads during dental radiographic examinations. (author)

  15. TL response of Eu activated LiF nanocubes irradiated by 85 MeV carbon ions

    Energy Technology Data Exchange (ETDEWEB)

    Salah, Numan, E-mail: nsalah@kau.edu.sa [Center of Nanotechnology, King Abdulaziz University, Jeddah 21589 (Saudi Arabia); Alharbi, Najlaa D. [Sciences Faculty for Girls, King Abdulaziz University, Jeddah 21589 (Saudi Arabia); Habib, Sami S. [Center of Nanotechnology, King Abdulaziz University, Jeddah 21589 (Saudi Arabia); Lochab, S.P. [Inter-University Accelerator Centre, Aruna Asaf Ali Marg, New Delhi 110067 (India)

    2015-09-01

    Carbon ions were found to be effective for cancer treatment. These heavy ions have a high relative biological effectiveness compared to those of photons. They have higher linear energy transfer and sharper Bragg peak with a very excellent local tumor control. However, the dose of these swift heavy ions needs to be measured with great accuracy. Lithium fluoride (LiF) is a highly sensitive phosphor widely used for radiation dosimetry. In this work Eu activated LiF nanocubes were exposed to 85 MeV C{sup 6+} ion beam and evaluated for their thermoluminescence (TL) response. Pellet forms of this nanomaterial were exposed to these ions in the fluence range 10{sup 9}–10{sup 13} ions/cm{sup 2}. The obtained result shows a prominent TL glow peak at around 320 °C, which is different than that induced by gamma rays. This glow peak exhibits a linear response in the range 10{sup 9}–10{sup 12} ions/cm{sup 2}, corresponding to the equivalent absorbed doses 0.273–273 kGy. The absorbed doses, penetration depths and main energy loss were calculated using TRIM code based on the Monte Carlo simulation. The supralinearity function and stopping power in this nanomaterial were also studied. The modification induced in the glow curve structure as a result of changing irradiation type might be utilized to use LiF:Eu nanocubes as a dosimeter for mixed filed radiations. Moreover, the wide linear response of LiF:Eu nanocubes along with the low fading are another imperative results suggesting that this nanomaterial might be a good candidate for carbon ions dosimetry.

  16. TL response of Eu activated LiF nanocubes irradiated by 85 MeV carbon ions

    International Nuclear Information System (INIS)

    Salah, Numan; Alharbi, Najlaa D.; Habib, Sami S.; Lochab, S.P.

    2015-01-01

    Carbon ions were found to be effective for cancer treatment. These heavy ions have a high relative biological effectiveness compared to those of photons. They have higher linear energy transfer and sharper Bragg peak with a very excellent local tumor control. However, the dose of these swift heavy ions needs to be measured with great accuracy. Lithium fluoride (LiF) is a highly sensitive phosphor widely used for radiation dosimetry. In this work Eu activated LiF nanocubes were exposed to 85 MeV C 6+ ion beam and evaluated for their thermoluminescence (TL) response. Pellet forms of this nanomaterial were exposed to these ions in the fluence range 10 9 –10 13 ions/cm 2 . The obtained result shows a prominent TL glow peak at around 320 °C, which is different than that induced by gamma rays. This glow peak exhibits a linear response in the range 10 9 –10 12 ions/cm 2 , corresponding to the equivalent absorbed doses 0.273–273 kGy. The absorbed doses, penetration depths and main energy loss were calculated using TRIM code based on the Monte Carlo simulation. The supralinearity function and stopping power in this nanomaterial were also studied. The modification induced in the glow curve structure as a result of changing irradiation type might be utilized to use LiF:Eu nanocubes as a dosimeter for mixed filed radiations. Moreover, the wide linear response of LiF:Eu nanocubes along with the low fading are another imperative results suggesting that this nanomaterial might be a good candidate for carbon ions dosimetry

  17. Evaluation of polymer-coated CsI:Tl as an alpha/beta pulse shape discriminating flow-cell

    International Nuclear Information System (INIS)

    Branton, S.D.; Fjeld, R.A.; DeVol, T.A.

    1996-01-01

    A pulse shape discriminating flow-cell radiation detection system constructed with polymer coated CsI:Tl was evaluated for simultaneous gross alpha/gross beta quantification. The CsI:TI scintillator was crushed and sieved to 63-90 μm particle size and microencapsulated with Parylene C to reduce its rate of dissolution. Averaged over the first hour of use, the pulse shape discrimination figure-of-merit was 1.4 and the detection efficiencies were 64.9 ± 5.7 %, 52.5 ± 4.5 % and 4.5 ± 0.2 % for 233 U, 90 Sr/ 90 Y and 14 C , respectively. The typical background count rate in the alpha and beta pulse shape window was 0.17 and 0.004 cps, respectively. The resultant minimum detectable activity for a 30 second count time was calculated to be 0.19 ± 0.01 Bq, 0.9 ± 0.1 Bq and 11.4 ± 0.6 Bq for 233 U, 90 Sr/ 90 Y and 14 C, respectively. Although the 3 μm thick microencapsulation reduced CsI:Tl dissolution, the detection efficiency declined by a factor of two after 4.8 hours while the pulse shape resolution degraded slightly

  18. Lattice distortions in TlInSe{sub 2} thermoelectric material studied by X-ray absorption fine structure

    Energy Technology Data Exchange (ETDEWEB)

    Hosokawa, Shinya; Stellhorn, Jens Ruediger [Department of Physics, Kumamoto University, Kumamoto (Japan); Ikemoto, Hiroyuki [Department of Physics, University of Toyama, Toyama (Japan); Mimura, Kojiro [Department of Mathematical Sciences, Graduate School of Engineering, Osaka Prefecture University, Sakai (Japan); Wakita, Kazuki [Faculty of Engineering, Chiba Institute of Technology, Narashino (Japan); Mamedov, Nazim [Institute of Physics, Azerbaijan National Academy of Sciences, Baku (Azerbaijan)

    2018-01-15

    Tl L{sub II} and In K X-ray absorption fine structure (XAFS) measurements were performed on a TlInSe{sub 2} thermoelectric material in the temperature range of 25-300 K including the incommensurate-commensurate phase transition temperature of about 135 K. Most of the bond lengths obtained from the present XAFS measurements are in good agreement with existing X-ray diffraction data at room temperature, while only the Tl-Tl correlation shows inconsistent values indicating the commensurate properties of the Tl chains expected from the thermodynamic properties. The present XAFS data clearly support positional fluctuations of the Tl atoms found in three-dimensional atomic images reconstructed from X-ray fluorescence holography. (copyright 2017 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  19. Patrón de respuesta de orientación - defensa : diferencias individuales y efectos sobre las respuestas fisiológicas

    OpenAIRE

    Crespo López, María

    1993-01-01

    Tras una revisión teórica de la caracterización, conceptualización y significación funcional de las respuestas de orientación (ro) y defensa (rd), se presenta un trabajo experimental que intenta determinar la posible existencia de diferencias individuales en la elicitación de ro o rd ante estímulos inocuos en una muestra de sujetos sin trastorno, así como las posibles diferencias que puedan producirse a todos los niveles en función del patrón ro/rd. Los resultados permitieron identificar un g...

  20. Pulse and integral optically stimulated luminescence (OSL). Similarities and dissimilarities to thermoluminescence (TL) dose dependence and dose-rate effects

    International Nuclear Information System (INIS)

    Chen, R.; Leung, P.L.

    2000-01-01

    Optically stimulated luminescence (OSL) and thermoluminescence (Tl) are two possible methods to monitor the absorbed radiation in solid samples, and therefore are utilized for dosimetry. For this application, two properties are desirable, namely, linear dose dependence of the measured quantity and dose-rate independence. For Tl, different kinds of super linear dose dependence have been reported in the literature in different materials, and in some cases, dose-rate dependence has also been found. These have been explained as being the result of competition. In OSL, some recent works reported on super linear dose dependence in annealed samples. In the present work, we explain the possible occurrence of these phenomena in OSL by solving numerically the relevant rate equations governing the process during irradiation, relaxation and read-out (heating or light stimulation). The results show that for short pulse OSL, quadratic dose dependence can be expected when only one trapping state and one kind of recombination center are involved and when the excitation starts with empty traps and centers. With the short pulse OSL, the calculation also reveals a possible dose-rate effect. Under the same circumstances, the area under the OSL curve depends linearly on the dose. The dependence of the whole area under the OSL curve on the dose is shown to be super linear when a disconnected trapping state or radiationless center take part in the process. Also, dose-rate effect can be expected in these cases, although no experimental effect of this sort has been reported so far. In pulse OSL, the analogy is made between the measured intensity and the initial rise range of non-first order Tl, whereas for the total area OSL, there is a nearly full analogy with the dose behavior of the Tl maximum. (Author)

  1. 201Tl scintigraphy in the evaluation of palpable and nonpalpable breast lesions: correlation with mammography and ultrasonography

    International Nuclear Information System (INIS)

    Vural, G.; Atasever, T.; Oezdemir, A.; Oeznur, I.; Karabacak, N.I.; Goekcora, N.; Isik, S.; Uenlue, M.

    1997-01-01

    Tl-201 scintigraphy were performed in sixty-eight patients with 70 breast abnormalities (51 palpable, 19 nonpalpable) and compared with mammography and ultrasonography (US). Early (15 min) and late (3 h) images of the breasts were obtained following the injection of 111 MBq (3 mCi) of Tl-201. Visual and semiquantitative interpretation was performed. Final diagnosis confirmed 52 malignant breast lesions and 18 benign conditions. Tl-201 visualized 47 of 52 (90%) overall malignant lesions. Thirty-eight of 40 (95%) palpable and 9 of 12 (75%) nonpalpable breast cancers were detected by Tl-201 scintigraphy. The smallest mass lesion detected by Tl-201 measured 1.5x1.0 cm. Eleven breast lesions were interpreted as indeterminate by mammography and/or sonography. Tl-201 scintigraphy excluded malignancy in 7 of 8 (88%) patients with benign breast lesions interpreted as indeterminate. Five of the 18 (28%) benign breast lesions showed Tl-201 uptake. None of the fibroadenoma and fibrocystic changes accumulated Tl-201. Tl-201 scintigraphy, mammography and ultrasonography showed 90%, 92%, 85% overall sensitivity and 72%, 56%, 61% overall specificity respectively. Twenty-one of the 28 (75%) axillary nodal metastatic sites were also detected by Tl-201. In malignant and benign lesions, early and late lesion/contralateral normal side (L/N) ratios were 1.58±0.38 (mean±SD) and 1.48±0.32 (p>0.05), 1.87±0.65 and 1.34±0.20 (p 0.05). (orig./MG) [de

  2. Activation analysis of thallium by /sup 203/Tl(n,2n)/sup 202/Tl reaction in nuclear reactors

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, I M; Resnizky, S M; Baro, G B [Comision Nacional de Energia Atomica, Buenos Aires (Argentina). Gerencia de Radioisotopos y Radiaciones

    1982-01-01

    Two techniques are described for neutron activation analysis of thallium in biological and geological materials, based on /sup 203/Tl(n,2n)/sup 202/Tl reaction in nuclear reactors. Co-precipitation with bismuth sulphide is used as a pre-concentration method of thallium in urine samples, and post-irradiation chemical separation is also performed. The detection limit is 0.5 ..mu..g/l, for 100 ml urine samples. For thallium determination in blendes a radiochemical separation is carried out after the irradiation. An extension of this technique is presented for glass and silicate rocks. Results for seven blende samples from different places of Argentina are shown. Analysis of two reference materials, the 614 glass from the National Bureau of Standards and the granodiorite GSP-1 from the U.S. Geological Survey were also performed. The results are in very good agreement with the certified or estimated values.

  3. Ionising radiation effect on the luminescence emission of inorganic and biogenic calcium carbonates

    Science.gov (United States)

    Boronat, C.; Correcher, V.; Virgos, M. D.; Garcia-Guinea, J.

    2017-06-01

    As known, the luminescence emission of mineral phases could be potentially employed for dosimetric purposes in the case of radiological terrorism or radiation accident where conventional monitoring is not available. In this sense, this paper reports on the thermo- (TL) and cathodoluminescence (CL) emission of both biogenic (common periwinkle - littorina littorera - shell made of calcite 90% and aragonite 10%) and inorganic (aragonite 100%) Ca-rich carbonates previously characterized by X-ray diffraction and Raman spectroscopy. Whereas the aragonite sample displays the main CL waveband peaked in the red region (linked to point defects), the more intense emission obtained from the common periwinkle shell appears at higher energies (mainly associated with structural defects). The UV-blue TL emission of the samples, regardless of the origin, displays (i) an acceptable ionizing radiation sensitivity, (ii) linear dose response in the range of interest (up to 8 Gy), (iii) reasonable stability of the TL signal after 700 h of storage with an initial decay of ca. 88% for the mineral sample and 60% for the biogenic sample and maintaining the stability from 150 h onwards. (iv) The tests of thermal stability of the TL emission performed in the range of 180-320 °C confirm a continuum in the trap system.

  4. Thermoluminescent dosimetry of ionizing radiations using ZrO2 prepared at low temperatures

    International Nuclear Information System (INIS)

    Rivera M, T.; Diaz G, J.A.I.; Olvera T, L.; Azorin N, J.; Barrera S, M.; Soto E, A.M.

    2005-01-01

    The thermoluminescent dosimetry (TLD) it is a versatile tool for an evaluation of dose of ionizing radiation. A great variety of ceramic materials and their different physical forms allow a determination of the ionizing radiation in a wide dose interval. In this work the results of studying those thermoluminescent characteristics (TL) of the zirconium oxide obtained by means of the sol-gel technique to low temperatures are presented. To these temperatures the material was obtained in its amorphous state (ZrO 2 -a). The structural characteristics of ZrO 2 -a they were obtained by means of X-ray diffraction. The TL characteristics studied were: TL curve, reproducibility of the TL signal and the fading of the information. The powders of ZrO 2 -a, previously irradiated with beta particles of 90 Sr/ 90 Y, they presented a thermoluminescent curve with two peaks at 150 and 260 C. The fading of the information of the one ZrO 2 -a it was of 20% during the first two hours starting from this time there was one lost of information of 5% to the finish of the 30 days. The reproducibility of the information was of ± 2.5% in standard deviation. (Author)

  5. Disquisition and technical alteration about TL apparatus

    International Nuclear Information System (INIS)

    Wang Guangxiang; Li Mingliang

    2002-01-01

    The author simply introduces the disadvantage of TL apparatus controlled by single chip. The project uses the PC computer to replace single chip control. So it must be changed the interface and made up a software with Chinese

  6. Superdeformation in the Hg-Tl-Pb region

    International Nuclear Information System (INIS)

    Henry, E.A.; Becker, J.A.; Yates, S.W.; Wang, T.F.; Kuhnert, A.; Brinkman, M.J.; Cizewski, J.A.; Deleplanque, M.A.; Diamond, R.M.; Stephens, F.S.; Azaiez, F.; Korten, W.; Draper, J.E.

    1990-10-01

    Superdeformation in the Hg-Tl-Pb region is discussed, with concentration on the experimental results. At least twenty-five superdeformed bands are known in this region, providing much new data to test theoretical calculations. 22 refs., 5 figs

  7. Evaluation of /sup 201/TlCl and delayed scan for thyroid imaging agent

    Energy Technology Data Exchange (ETDEWEB)

    Taniguchi, Tatsuyoshi; Harada, Taneichi; Takahashi, Tatsuo; Senoo, Tsuneaki; Ohtsuka, Nobuaki; Ito, Yasuhiko [Kawasaki Medical School, Kurashiki, Okayama (Japan)

    1982-11-01

    The results of 189 patients with nodular goiter by imaging with /sup 201/TlCl following with sup(99m)TcO/sub 4//sup -/ was presented. Accumulation of /sup 201/TlCl to the corresponding area was observed in 85.5% of cancer, 62.2% of adenoma, 42.5% of adenomatous goiter, and the usefulness of /sup 201/TlCl (early scan) for thyroid imaging agent was recognized. On the other hand, delayed scan for purpose of differentiation from benign to malignant was also performed. However, no significant differences were obtained.

  8. Program for the evaluation of TL-brick dating: 'ADAM-1-EVA'

    International Nuclear Information System (INIS)

    Novotna, V.; Kubelik, M.; Musilek, L.

    2000-01-01

    Although the evaluation of the TL-mean date has presented very little diversity since first published, the error evaluation has prompted a lot of discussion. Particularly the physical, chemical, statistical and mathematical differences as reflected in the specifics of the evaluation of the individual random and systematic errors in ceramic and brick dating are undervalued in literature. The construction of an automated TL-Reader (ADAM-1) at the Czech Technical University in Prague was taken as an opportunity to create a whole new software package for the evaluation ('EVA') of TL-dates. ADAM-1 is designed primarily for brick dating, using the fine-grain technique. The philosophy of data processing is similar to that applied by the Berlin group in their research of Venetian Villas. The program was developed using Delphi, as it is user-friendlier than pure Pascal, offers a strong graphic platform and allows flexibility in data management. This was important, as the program was conceived to either interact directly with ADAM-1, or to be operated independently for data evaluation and management. The software package consists of two discrete yet combinable components: one for the calculation of the TL mean date, using all raw data obtained from ADAM-1 and peripheral measurements; the other for the evaluation of systematic, random and context errors of individual samples and sample groups. All steps in the calculations are also graphically available, e.g. glow curves, plateau test, TL vs. dose dependence and charts summarising the results of all calculations for an individual sample and a given context. (author)

  9. Usefulness of 201Tl myocardial scintigraphy after dipyridamole infusion in patients with atherosclerotic vascular disease

    International Nuclear Information System (INIS)

    Toyama, Takuji; Nishimura, Tsunehiko; Uehara, Toshiisa

    1992-01-01

    To determine the utility for detecting ischemic heart disease (IHD), dipyridamole thallium myocardial images (DIP-Tl) have been performed in 103 patients with atherosclerotic vascular disease who can't exercise fully. Of the 103 patients, there were 36 patients with arteriosclerosis obliterans (ASO), 31 patients with aneurysm of the abdominal aorta (AAA), 24 patients with aneurysm of the thoracic aorta (TAA) and 12 patients with dissecting aortic aneurysm (DAA). Clinical evidence of IHD was found in 20 patients with ASO, 10 with AAA, 7 with TAA and 4 with DAA. Positive evidence of DIP-Tl was identified in 66% of 41 patients who had clinical evidence of IHD, and particularly in the patients with AAA (80%) and ASO (65%). On the other hand, in the patients without clinical evidence of IHD, positive evidence of DIP-Tl was identified in 19% of 62 patients and particularly in the patients with AAA (39%). In all patients, the percentage of the positive DIP-Tl ratio was 38%. And, when the 38% patients of the positive DIP-Tl were added to the patients of the negative DIP-Tl who had clinical evidence of IHD, almost half patients (51%) were considered to be complicated with IHD. This study suggests that the atherosclerotic vascular disease is highly complicated with IHD and DIP-Tl is useful to detect IHD. (author)

  10. Development and testing of a thermoluminescent dosemeter for mixed neutron-photon-beta radiation fields

    International Nuclear Information System (INIS)

    Zummo, J.J.; Liu, J.C.

    1998-08-01

    A new four-element thermoluminescent (TL) dosemeter and dose evaluation algorithm have been developed and tested to better characterize personnel exposure in mixed neutron-photon-beta radiation fields. The prototype dosemeter is based on a commercially available TL card (with three LiF-7 chips and one LiF-6 chip) and modified filtration elements. The new algorithm takes advantage of the high temperature peak characteristics of the LiF-6 element to better quantify the neutron dose component. The dosemeter was tested in various radiation fields, consisting of mixtures of two radiation types typically used for dosemeter performance testing, as well as mixtures of three radiation types to simulate possible exposure conditions. The new dosemeter gave superior performance, based on the tolerance levels, when using the new algorithm as compared to a conventional algorithm that did not use the high temperature peak methodology. The limitations and further improvements are discussed

  11. Efectos no deseados por la comunicación digital en la respuesta moral

    Directory of Open Access Journals (Sweden)

    Isidoro Arroyo Almaraz

    2015-01-01

    Full Text Available Se investiga cómo la comunicación mediada por tecnologías digitales modifica la respuesta moral de los usuarios, y por tanto, varía el capital social. Se diseña y realiza un experimento con 196 sujetos que se sirve de una adaptación de diseño propio del «Defining Issues Test» en papel, a partir de la versión española, sobre una muestra representativa del universo de sujetos que se han socializado con Internet. Se valida la adaptación del test sometiéndolo a juicio por un panel de expertos, se amplía el mismo a otros dos formatos digitales audiovisuales diferentes: con imágenes reales de personas o con imágenes virtuales de personas a través de animación, y se comprueba si la inteligencia fluida de los sujetos es significativa en la modificación de la respuesta moral. Los resultados confirman las hipótesis y demuestran que la calidad de la respuesta moral disminuye cuando se usan tecnologías digitales respecto a cuando se usa papel y lápiz. Esta diferencia es mayor cuando se usan imágenes virtuales de personas a través de animación que cuando se usan imágenes audiovisuales de personas reales. En todos los casos la inteligencia fluida es un atenuante de estas modificaciones.

  12. SCOPE-mTL: A non-invasive tool for identifying and lateralizing mesial temporal lobe seizures prior to scalp EEG ictal onset.

    Science.gov (United States)

    Lam, Alice D; Maus, Douglas; Zafar, Sahar F; Cole, Andrew J; Cash, Sydney S

    2017-09-01

    In mesial temporal lobe (mTL) epilepsy, seizure onset can precede the appearance of a scalp EEG ictal pattern by many seconds. The ability to identify this early, occult mTL seizure activity could improve lateralization and localization of mTL seizures on scalp EEG. Using scalp EEG spectral features and machine learning approaches on a dataset of combined scalp EEG and foramen ovale electrode recordings in patients with mTL epilepsy, we developed an algorithm, SCOPE-mTL, to detect and lateralize early, occult mTL seizure activity, prior to the appearance of a scalp EEG ictal pattern. Using SCOPE-mTL, 73% of seizures with occult mTL onset were identified as such, and no seizures that lacked an occult mTL onset were identified as having one. Predicted mTL seizure onset times were highly correlated with actual mTL seizure onset times (r=0.69). 50% of seizures with early mTL onset were lateralizable prior to scalp ictal onset, with 94% accuracy. SCOPE-mTL can identify and lateralize mTL seizures prior to scalp EEG ictal onset, with high sensitivity, specificity, and accuracy. Quantitative analysis of scalp EEG can provide important information about mTL seizures, even in the absence of a visible scalp EEG ictal correlate. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  13. Indentification of radiation treatment of wheat (triticum aestivum. L) and rice (oryza sativa. L) samples using thermoluminescence of contaminating minerals

    International Nuclear Information System (INIS)

    Khan, H.M.; Bhatti, I.A.

    2007-01-01

    Food irradiation is gaining popularity worldwide and this technology is important to improve quality and reduce the post harvest losses of food. Because of the rapid commercialization of irradiated foods throughout the world, compliance of different regulations relating to use of technology in different countries and demand of consumers for clear labelling of irradiated foods, there is need for the development of analytical methods to detect radiation treatment of food. Among several methods studied so far, thermoluminescence (TL) is an important method that can be used to find out the irradiation history of food that contain even a very minute amount of dust particles. In this study, the irradiated and unirradiated wheat and rice samples were analyzed using the TL method. The samples were purchased from the local market of Peshawar and irradiated to radiation doses of 0.5 and 1.0 kGy using Co-60 gamma irradiator at the Nuclear Institute for Food and Agriculture (NIFA), Peshawar. The mineral contaminants were isolated by jet water, ultrasonic treatment, and density gradient. TL glow curves of the isolated minerals from irradiated and unirradiated samples were recorded between the temperature ranges of 50-500 degree C using a TL reader. Generally, the glow curves for irradiated samples showed much higher TL intensities (TL 1 ) than the unirradiated samples. The results were normalized by re-irradiation of mineral samples to gamma-ray dose of 1.0 kGy followed by determination of the second glow curves (TM). The ratio of the area of first glow curve to that of second glow curve (TL 1 /TL 2 ) was calculated for selected temperature intervals and compared with the recommended values for unirradiated and irradiated samples. Finally, the shapes of the glow curves for irradiated and unirradiated samples were also analyzed. On the ba- sis of these results (comparison of TL-intensities, TL 1 /TL 2 ratios and shapes of the glow curves), all the irradiated and unirradiated

  14. A portable in situ NaI(Tl) γ spectroscopy system

    International Nuclear Information System (INIS)

    Wang Bairong; Dong Binjiang; Zeng Liping

    1999-01-01

    The author describes a portable in situ NaI(Tl) γ spectroscopy system, which consists of a NaI(Tl) scintillation detector, an integrative spectroscopy card, a notebook computer and the spectroscopy software. The spectrometer addresses applications in environmental or nuclear accident in situ γ spectroscopy measurements, and gives valid quantitative results of radionuclide concentrations per unit volume (Bq/kg) or per unit area (Bq/cm 2 ) in the soil and absorbed dose rate in air 1 m above ground (Gy/h)

  15. Exfoliated graphite with graphene flakes as potential candidates for TL dosimeters at high gamma doses.

    Science.gov (United States)

    Ortiz-Morales, A; López-González, E; Rueda-Morales, G; Ortega-Cervantez, G; Ortiz-Lopez, J

    2018-06-06

    Graphite powder (GP) subjected to microwave radiation (MWG) results in exfoliation of graphite particles into few-layered graphene flakes (GF) intermixed with partially exfoliated graphite particles (PEG). Characterization of MWG by Scanning Electron Microscopy (SEM), Atomic Force Microscopy (AFM) and Raman spectroscopy reveal few-layer GF with sizes ranging from 0.2 to 5 µm. Raman D, G, and 2D (G') bands characteristic of graphitic structures include evidence of the presence of bilayered graphene. The thermoluminescent (TL) dosimetric properties of MWG are evaluated and can be characterized as a gamma-ray sensitive and dose-resistant material with kinetic parameters (activation energy for the main peak located at 400 and 408 K is 0.69 and 0.72 eV) and threshold dose (~1 kGy and 5 kGy respectively). MWG is a low-Z material (Z eff = 6) with a wide linear range of TL dose-response (0.170-2.5 kGy) tested at doses in the 1-20 kGy range with promising results for applications in gamma-ray dosimetry. Results obtained in gamma irradiated MWG are compared with those obtained in graphite powder samples (GP) without microwave treatment. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Structural behavior of Tl-exchanged natrolite at high pressure depending on the composition of pressure-transmitting medium

    Science.gov (United States)

    Seryotkin, Yu. V.; Bakakin, V. V.; Likhacheva, A. Yu.; Dementiev, S. N.; Rashchenko, S. V.

    2017-10-01

    The structural evolution of Tl-exchanged natrolite with idealized formula Tl2[Al2Si3O10]·2H2O, compressed in penetrating (water:ethanol 1:1) and non-penetrating (paraffin) media, was studied up to 4 GPa. The presence of Tl+ with non-bonded electron lone pairs, which can be either stereo-chemically active or passive, determines distinctive features of the high-pressure behavior of the Tl-form. The effective volume of assemblages Tl+(O,H2O) n depends on the E-pairs activity: single-sided coordination correlates with smaller volumes. At ambient conditions, there are two types of Tl positions, only one of them having a nearly single-sided coordination as a characteristic of stereo-activity of the Tl+ E pair. Upon the compression in paraffin, a phase transition occurs: a 5% volume contraction of flexible natrolite framework is accompanied by the conversion of all the Tl+ cations into stereo-chemically active state with a single-sided coordination. This effect requires the reconstruction of all the extra-framework subsystems with the inversion of the cation and H2O positions. The compression in water-containing medium leads to the increase of H2O content up to three molecules pfu through the filling of partly vacant positions. This hinders a single-sided coordination of Tl ions and preserves the configuration of their ion-molecular subsystem. It is likely that the extra-framework subsystem is responsible for the super-structure modulation.

  17. Factores asociados a una respuesta inadecuada a la vacunación contra la hepatitis B en personal sanitario

    Directory of Open Access Journals (Sweden)

    Tolosa Martínez Natividad

    1998-01-01

    Full Text Available FUNDAMENTO: La vacuna recombinante contra la hepatitis B confiere inmunidad aproximadamente en el 95 % de los casos, pero existe un porcentaje que responde insuficientemente. El objetivo de este trabajo es evaluar los factores que se asocian con una inadecuada respuesta inmunitaria. MÉTODOS: Se trata de un estudio observacional y analítico en el que se sigue retrospectivamente una cohorte de sujetos vacunados frente al virus de la hepatitis B (VHB. Se recogieron las variables de interés del personal sanitario que cumplía los criterios de inclusión, del Área de Salud 9 de la Comunidad Valenciana (n=827. Tras la vacunación se determinó la titulación de anticuerpos de superficie (antiHBs para comprobar la respuesta, considerándose niveles protectores los superiores a 10 mUI/ml. RESULTADOS: Se produjo una adecuada seroconversión en el 94,4% de los vacunados. La baja o nula respuesta a la vacuna se asoció significativamente y de forma independiente con variables como el sexo masculino, la edad, el índice de masa corporal (IMC y el tabaquismo. El consumo de alcohol y los niveles de GPT, aunque no se relacionaron de forma significativa con la respuesta a la vacuna, actuaron como posibles factores de confusión. CONCLUSIONES: La inmunogenicidad de la vacuna es satisfactoria. Es importante cuantificar los niveles de antiHBs, sobretodo cuando hay factores predictivos de mala respuesta. De esta manera, es posible identificar a aquellos que precisan dosis de recuerdo y a los no respondedores, evitándose así situaciones de falsa sensación de protección frente al VHB.

  18. Streptomyces venezuelae TX-TL - a next generation cell-free synthetic biology tool.

    Science.gov (United States)

    Moore, Simon J; Lai, Hung-En; Needham, Hannah; Polizzi, Karen M; Freemont, Paul S

    2017-04-01

    Streptomyces venezuelae is a promising chassis in synthetic biology for fine chemical and secondary metabolite pathway engineering. The potential of S. venezuelae could be further realized by expanding its capability with the introduction of its own in vitro transcription-translation (TX-TL) system. TX-TL is a fast and expanding technology for bottom-up design of complex gene expression tools, biosensors and protein manufacturing. Herein, we introduce a S. venezuelae TX-TL platform by reporting a streamlined protocol for cell-extract preparation, demonstrating high-yield synthesis of a codon-optimized sfGFP reporter and the prototyping of a synthetic tetracycline-inducible promoter in S. venezuelae TX-TL based on the tetO-TetR repressor system. The aim of this system is to provide a host for the homologous production of exotic enzymes from Actinobacteria secondary metabolism in vitro. As an example, the authors demonstrate the soluble synthesis of a selection of enzymes (12-70 kDa) from the Streptomyces rimosus oxytetracycline pathway. © 2017 The Authors. Biotechnology Journal published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Incidence of radiation pneumonitis after thoracic irradiation: Dose-volume correlates

    International Nuclear Information System (INIS)

    Schallenkamp, John M.; Miller, Robert C.; Brinkmann, Debra H.; Foote, Tyler; Garces, Yolanda I.

    2007-01-01

    Purpose: To define clinical and dosimetric parameters correlated with the risk of clinically relevant radiation pneumonitis (RP) after thoracic radiotherapy. Methods and Materials: Records of consecutive patients treated with definitive thoracic radiotherapy were retrospectively reviewed for the incidence of RP of Grade 2 or greater by the Common Toxicity Criteria. Dose-volume histograms using total lung volume (TL) and TL minus gross tumor volume (TL-G) were created with and without heterogeneity corrections. Mean lung dose (MLD), effective lung volume (V eff ), and percentage of TL or TL-G receiving greater than or equal to 10, 13, 15, 20, and 30 Gy (V10-V30, respectively) were analyzed by logistic regression. Receiver operating characteristic (ROC) curves were generated to estimate RP predictive values. Results: Twelve cases of RP were identified in 92 eligible patients. Mean lung dose, V10, V13, V15, V20, and V eff were significantly correlated to RP. Combinations of MLD, V eff , V20, and V30 lost significance using TL-G and heterogeneity corrections. Receiver operating characteristic analysis determined V10 and V13 as the best predictors of RP risk, with a decrease in predictive value above those volumes. Conclusions: Intrathoracic radiotherapy should be planned with caution when using radiotherapy techniques delivering doses of 10 to 15 Gy to large lung volumes

  20. Stable room-temperature thallium bromide semiconductor radiation detectors

    Science.gov (United States)

    Datta, A.; Fiala, J.; Becla, P.; Motakef, Shariar

    2017-10-01

    Thallium bromide (TlBr) is a highly efficient ionic semiconductor with excellent radiation detection properties. However, at room temperature, TlBr devices polarize under an applied electric field. This phenomenon not only degrades the charge collection efficiency of the detectors but also promotes chemical reaction of the metal electrodes with bromine, resulting in an unstable electric field and premature failure of the device. This drawback has been crippling the TlBr semiconductor radiation detector technology over the past few decades. In this exhaustive study, this polarization phenomenon has been counteracted using innovative bias polarity switching schemes. Here the highly mobile Br- species, with an estimated electro-diffusion velocity of 10-8 cm/s, face opposing electro-migration forces during every polarity switch. This minimizes the device polarization and availability of Br- ions near the metal electrode. Our results indicate that it is possible to achieve longer device lifetimes spanning more than 17 000 h (five years of 8 × 7 operation) for planar and pixelated radiation detectors using this technique. On the other hand, at constant bias, 2500 h is the longest reported lifetime with most devices less than 1000 h. After testing several biasing switching schemes, it is concluded that the critical bias switching frequency at an applied bias of 1000 V/cm is about 17 μHz. Using this groundbreaking result, it will now be possible to deploy this highly efficient room temperature semiconductor material for field applications in homeland security, medical imaging, and physics research.

  1. Stable room-temperature thallium bromide semiconductor radiation detectors

    Directory of Open Access Journals (Sweden)

    A. Datta

    2017-10-01

    Full Text Available Thallium bromide (TlBr is a highly efficient ionic semiconductor with excellent radiation detection properties. However, at room temperature, TlBr devices polarize under an applied electric field. This phenomenon not only degrades the charge collection efficiency of the detectors but also promotes chemical reaction of the metal electrodes with bromine, resulting in an unstable electric field and premature failure of the device. This drawback has been crippling the TlBr semiconductor radiation detector technology over the past few decades. In this exhaustive study, this polarization phenomenon has been counteracted using innovative bias polarity switching schemes. Here the highly mobile Br− species, with an estimated electro-diffusion velocity of 10−8 cm/s, face opposing electro-migration forces during every polarity switch. This minimizes the device polarization and availability of Br− ions near the metal electrode. Our results indicate that it is possible to achieve longer device lifetimes spanning more than 17 000 h (five years of 8 × 7 operation for planar and pixelated radiation detectors using this technique. On the other hand, at constant bias, 2500 h is the longest reported lifetime with most devices less than 1000 h. After testing several biasing switching schemes, it is concluded that the critical bias switching frequency at an applied bias of 1000 V/cm is about 17 μHz. Using this groundbreaking result, it will now be possible to deploy this highly efficient room temperature semiconductor material for field applications in homeland security, medical imaging, and physics research.

  2. Prediction of improvement of myocardial wall motion after coronary artery bypass surgery using rest Tl-201/dipyridamole stress gated Tc-99m-MIBI/24 hour delay Tl-201 SPECT

    International Nuclear Information System (INIS)

    Lee, Dong Soo; Lee, Won Woo; Yeo, Jeong Yeo; Kim, Seok Ki; Kim, Ki Bong; Chung, June Key; Lee, Myung Chul

    1998-01-01

    Using rest Tl-201/ dipyridamole stress gated Tc-99m-MIBI/24 hour delay Tl-201 SPECT, we investigated the predictive values of the markers of the stress-rest reversibility (Rev), Tl-201 rest perfusion (Rest), Tl-201 24 hour redistribution (Del) and Tc-99m-MIBI gated systolic thickening (Thk) for wall motion improvement after coronary artery bypass surgery. In 39 patients (M:F=34:5, age 58±8), preoperative and postoperative (3 months) SPECT were compared. 24 hour delayed SPECT was done in 16 patients having perfusion defects at rest. Perfusion or wall motion was scored from 0 to 3 (0: normal to 3: defect or dyskinesia). Wall motion was abnormal in 142 segments among 585 segments of 99 artery territories which were surgically revascularized. After bypass surgery, ejection fraction increased from 37.8±9.0% to 45.5±12.3% in 22 patients who had decreased ejectin fraction preoperatively. Wall motion improved in 103 (72.5%) segments among 142 dysfunctional segments. Positive predictive values (PPV) of Rev, Rest, Del, and Thk were 83%, 76%, 43%, and 69% respectively. Negative predictive values (NPV) of Rev, Rest, Del, and Thk were 48%, 44%, 58%, and 21%, respectively. Rest/gated stress/delay SPECT had PPV of 74% and NPV of 46%. Through univariate logistic regression analysis revealed Rev( p=0.0008) and Rest (p=0.024) as significant predictors, stepwise multivariate test found Rev as the only good predictor (p=0.0008). Among independent predictors obtained by rest Tl-201/stress gated Tc-99m-MIBI/delayed Tl-201 myocardial SPECT for wall motion improvement after bypass surgery, stress-rest reversibility was the single most useful predictor

  3. Quantitative evaluation of right ventricular overload in cor pulmonale using 201Tl myocardial SPECT

    International Nuclear Information System (INIS)

    Kato, Hiroshi; Misawa, Toshihiro; Kutsumi, Yasunori

    1991-01-01

    To determine quantitatively the discriminant and characteristics of cor pulmonale, 201 Tl myocardial perfusion SPECT was performed in 16 patients with chronic obstructive pulmonary disease (COPD) and 7 with restrictive pulmonary disease (RPD). One section of the short-axis SPECT image in which the right ventricle was most clearly visualized was selected. Tl-score was defined as the ratio of the sum of counts in the region of interest (ROI) at the anterior, mid, and posterior regions of the right ventricular free wall to the sum of counts in ROI at the posterior, lateral, and anterior walls of the left ventricle, and the anterior and posterior regions of the interventricular septum. In the group of COPD patients, Tl-score was positively correlated with mean pulmonary arterial pressure (mPAP), total pulmonary vascular resistance (TPR), and arterial carbon dioxide tension (PaCO 2 ), while it was inversely correlated with arterial oxygen tension (PaO 2 ). However, there was no significant correlation between Tl-score and mPAP, TPR, PaCO 2 , and PaO 2 in the group of RPD patients. In assessing pulmonary hypertension as defined by mPAP over 20 mmHg, a Tl-score greater than 0.25 was useful with a sensitivity of 69% and a specificity of 90%. The occurrence of cor pulmonale is a major factor in determining the prognosis of COPD patients. It was concluded that 201 Tl myocardial SPECT is useful for evaluating right ventricular overload quantitatively, as well as for assessing core pulmonale, especially in COPD patients, since the ratio of Tl counts in the right and left ventricles was significantly correlated with right cardiopulmonary hemodynamic parameters. (N.K.)

  4. Effects of cross talk on dual energy SPECT imaging between 123I-BMIPP and 201Tl

    International Nuclear Information System (INIS)

    Morita, Masato; Narita, Hitoshi; Yamamoto, Juro; Fukutake, Naoshige; Ohyanagi, Mitsumasa; Iwasaki, Tadaaki; Fukuchi, Minoru

    1994-01-01

    The study was undertaken to determine how much cross talk influences the visual assessment of dual energy single photon emission computed tomographic (SPECT) images with iodine 123 beta-methyl-p-iodophenylpentadecanoic acid (I-123 BMIPP) and thallium-201 in 15 patients with acute myocardial infarction. After single SPECT with I-123 BMIPP was undertaken, simultaneous dual SPECT with I-123 BMIPP and Tl-201 were undertaken in all patients. Three patients also underwent single SPECT with Tl-201. I-123 BMIPP and Tl-201 uptake was graded in four-score for the comparison between single and dual SPECT images. There was good correlation between dual energy SPECT and both single I-123 BMIPP SPECT (pS=0.97) and single Tl-201 SPECT (pS=0.59). Uptake scores were increased on dual energy SPECT, compared with single I-123 SPECT (8 out of 132 segments) and single Tl-201 SPECT (12 out of 36 segments). Overall, there was a comparatively well correlation between single SEPCT with either I-123 BMIPP or Tl-201 and dual energy SPECT images. However, one tracer uptake sometimes increased in the other tracer defect areas. This was noticeable when I-123 BMIPP exerted an effect on Tl-201. (N.K.)

  5. Study of multi-quasiparticle band structures in 197Tl using α beam

    International Nuclear Information System (INIS)

    Mukherjee, G.; Nandi, S.; Pai, H.

    2016-01-01

    Study of the multi-quasiparticle (qp) states and the band structures built on them in the neutron deficient Tl nuclei in A ∼ 190 mass region provides useful information on particle-hole interaction in the heavy nuclei. In order to investigate the multi-qp band structures we have studied the excited states in 197 Tl by gamma ray spectroscopy

  6. Tumor and infection localization in AIDS patients: Ga-67 and Tl-201 findings.

    Science.gov (United States)

    Turoglu, H T; Akisik, M F; Naddaf, S Y; Omar, W S; Kempf, J S; Abdel-Dayem, H M

    1998-07-01

    Examples of Ga-67 and Tl-201 scans in AIDS patients performed at St. Vincent's Hospital and Medical Center of New York are presented. Use of these methods is the adopted approach at this institution in AIDS patients for localizing sites of tumor or infection involvement. A Ga-67 scan is the most common nuclear medicine examination performed on AIDS patients. Sequential Tl-201 and Ga-67 scans have a role in differentiating Kaposi's sarcoma from malignant lymphoma and opportunistic infections. For intracranial lesions, Tc-99m MIBI or Tl-201-201-201-201 chloride can differentiate malignant from benign inflammatory lesions.

  7. Radiation Shielding Properties of Some Marbles in Turkey

    International Nuclear Information System (INIS)

    Guenoglu, K.; Akkurt, I.

    2011-01-01

    Especially after development of technology, radiation started to be used in a large fields such as medicine, industry and energy. Using radiation in those fields bring hazardous effect of radiation into humancell. Thus radiation protection becomes important in physics. Although there are three ways for radiation protection, shielding of the radiation is the most commonly used method. Natural Stones such as marble is used as construction material especially in critical building and thus its radiation shielding capability should be determined.In this study, gamma ray shielding properties of some different types of marble mined in Turkey, have been measured using a NaI(Tl) scintillator detector. The measured results were also compared with the theoretical calculations XCOM.

  8. Temperature dependence of positron annihilation parameters in Tl-Ba-Ca-Cu-O superconductors

    International Nuclear Information System (INIS)

    Sundar, C.S.; Bharathi, A.; Ching, W.Y.; Jean, Y.C.; Hor, P.H.; Meng, R.L.; Huang, Z.J.; Chu, C.W.

    1990-01-01

    The results of positron lifetime and Doppler broadened line-shape parameter measurements as a function of temperature, across T c , in the Tl-Ba-Ca-Cu-O superconductors are presented. The bulk lifetime in the normal state is found to decrease with the increase in the number of CuO 2 layers. Different temperature dependencies of the annihilation parameters are observed in the various Tl systems containing different numbers of CuO 2 layers. In the Tl 2 Ba 2 Ca 2 Cu 3 O 10 system, an increase in lifetime is observed below T c , whereas in Tl 2 Ba 2 CaCu 2 O 8 , a decrease in lifetime is seen below T c . In the Tl 2 Ba 2 CuO 6 system, the lifetime is observed to be temperature independent. The different temperature variations of positron annihilation parameters are discussed in the light of the positron density distribution, obtained with use of the results of the self-consistent orthogonalized linear combination of atomic orbitals band-structure calculations. It is argued that the different temperature dependencies of the annihilation parameters is related to the positron density distribution within the unit cell and arise due to local charge transfer in the vicinity of the CuO 2 layer in the superconducting state

  9. Use of TL - dosimeters of TLD - 500K type for precision estimation of spatial distributions of mixed dose fields in 'Ukryttia' conditions

    CERN Document Server

    Lagutin, I G; Ershova, N N

    2003-01-01

    In some works being currently carried out in ISTC 'Ukryttia' divisions within the framework of 'Complex program of works at 'Ukryttia' object', a necessary arose to estimate local values of radiation dose fields of mixed type (beta + gamma). The most convenient tool for estimation of local values of long - term integrals of such doses are dosimeters fabricated on the basis of thermoluminescent detectors (TLD) having small sensitive volume under sufficient radiating capacity, convenient performance and high reproducibility of results. It was offered to use TL - detectors of TLD-500K type on the basis of sapphire monocrystal (alpha-Al sub 2 O sub 3).

  10. A study of the effect of natural radiation damage in a zircon crystal using thermoluminescence, fission track etching and X-ray diffraction

    International Nuclear Information System (INIS)

    Amin, Y.M.

    1989-01-01

    The natural radiation damage in zircon caused by the decay of uranium and thorium, present as impurities, is studied. The radiation damage is first gauged by etching the fission tracks. It is found that thermoluminescence (TL) sensitivity (defined as light output per unit test-dose) decreases as the radiation damage increases, suggesting a destruction of TL centers. The spacing d of the (112)-plane is also measured. It is also found that the d-value increases with radiation damage, suggesting the displacement of atoms from their normal lattice sites. However, as the track density increases beyond ≅ 3x10 6 tracks/cm 2 , the d-value remains at ≅ 2.52 A. By annealing the crystal, the displaced atoms are found to return to the original lattice sites, and this is followed by a reduction in d-value as well as the recovery of TL sensitivity. The fission track density also decreases and all the tracks disappear at the annealing temperature of ≅ 800 0 C. (orig.)

  11. Proceso de respuesta a examen de egreso en contabilidad: validación de constructo

    Directory of Open Access Journals (Sweden)

    Sandra Castañeda Figueiras

    2007-06-01

    Full Text Available Se investiga la validación de constructo de seis dimensiones que están en la base del examende egreso de una licenciatura en contabilidad, con el fin de entender el proceso de respuesta subyacente. A partir de las respuestas a 17 ítems objetivos aplicados de manera grupal a 313 participantes seleccionados según muestreo intencional, se realizó un análisis factorial confirmatorio MRMM, en el que se representaron tres operaciones cognitivas demandadas para resolver los ítems y los métodos, así como los tres campos de conocimiento del contenido que se evalúa en ellos. El modelo resultante muestra bondad de ajuste, validez convergente entre dos constructos y sus variables manifiestas, además de validez divergente solo entre el conocimiento técnico y el combinado. El proceso de respuesta fue explicado, simultáneamente, por la operación comprender, influida por el conocimiento teórico. Se discuten las implicancias para comprender el proceso de respuesta en este tipo de examen a partir de la validación de constructo realizada.---The construct validity of six hypothesized dimensions was explored for an Accountancy major graduation examination, in order to understand the underlying process of responding. Using answers from 313 examinees to an intentional sample of 17 objective items administered on large scale, a confirmatory factorial analysis was carried out, with a Multi-Trait Multi-Methodmatrix (MTMM: Traits represented three cognitive operations required to solve the items and the methods represented three knowledge fields of the content. Each item was linked to a cognitive operation and to a knowledge field. The resulting model showed convergent validity in two constructs and its manifest variables and divergent only between technical and combined knowledge. Thus, the answering process was explained, simultaneously by the Understanding operation influenced by Theoretical knowledge. Implications to understanding the answering process

  12. Tl{sub 10}Hg{sub 3}Cl{sub 16}: Single crystal growth, electronic structure and piezoelectric properties

    Energy Technology Data Exchange (ETDEWEB)

    Khyzhun, O.Y., E-mail: khyzhun@ipms.kiev.ua [Frantsevych Institute for Problems of Materials Science, National Academy of Sciences of Ukraine, 3 Krzhyzhanivsky Street, 03142 Kyiv (Ukraine); Piasecki, M. [Institute of Physics, J.Dlugosz University Częstochowa, Armii Krajowej 13/15, Częstochowa PL-42-217 (Poland); Kityk, I.V. [Electrical Engineering Department, Częstochowa University Technology, Armii Krajowej 17, PL-42-200 Częstochowa (Poland); Luzhnyi, I. [Frantsevych Institute for Problems of Materials Science, National Academy of Sciences of Ukraine, 3 Krzhyzhanivsky Street, 03142 Kyiv (Ukraine); Fedorchuk, A.O. [Department of Inorganic and Organic Chemistry, Lviv National University of Veterinary Medicine and Biotechnologies, 50 Pekarska Street, 79010 Lviv (Ukraine); Fochuk, P.M. [Yuriy Fed’kovych Chernivtsi National University, 2 Kotziubynskoho Street, 58012 Chernivtsi (Ukraine); Levkovets, S.I. [Department of Inorganic and Physical Chemistry, Lesya Ukrainka Eastern European National University, 13 Voli Avenue, 43025 Lutsk (Ukraine); Karpets, M.V. [Frantsevych Institute for Problems of Materials Science, National Academy of Sciences of Ukraine, 3 Krzhyzhanivsky Street, 03142 Kyiv (Ukraine); Parasyuk, O.V. [Department of Inorganic and Physical Chemistry, Lesya Ukrainka Eastern European National University, 13 Voli Avenue, 43025 Lutsk (Ukraine)

    2016-10-15

    Single crystal of the ternary halide Tl{sub 10}Hg{sub 3}Cl{sub 16} was grown using Bridgman-Stockbarger method. For the Tl{sub 10}Hg{sub 3}Cl{sub 16} crystal, we have measured X-ray photoelectron spectra for both pristine and Ar{sup +} ion-bombarded surfaces and additionally investigated photoinduced piezoelectricity. Our data indicate that the Tl{sub 10}Hg{sub 3}Cl{sub 16} single crystal surface is very sensitive with respect to Ar{sup +} ion-bombardment. In particular, Ar{sup +} ion-bombardment with energy of 3.0 keV over 5 min at an ion current density of 14 μA/cm{sup 2} causes significant changes of the elemental stoichiometry of the Tl{sub 10}Hg{sub 3}Cl{sub 16} surface resulting in an abrupt decrease of the mercury content in the top surface layers of the studied single crystal. As a result of the treatment, the mercury content becomes nil in the top surface layers. In addition, the present XPS measurements allow for concluding about very low hygroscopicity of the Tl{sub 10}Hg{sub 3}Cl{sub 16} single crystal surface. The property is extremely important for the crystal handling in optoelectronic or nano-electronic devices working at ambient conditions. The photoinduced piezoelectricity has been explored for Tl{sub 10}Hg{sub 3}Cl{sub 16} depending on nitrogen (λ=371 nm) laser power density and temperature. - Graphical abstract: As-grown single crystal boule of Tl{sub 10}Hg{sub 3}Cl{sub 16}; dependence of the effective piezoelecric coefficient d{sub 33} versus the photoinducing nitrogen laser power density, I, at different temperatures, T; and packing of the polyhedra of halide atoms around Hg atoms in the Tl{sub 10}Hg{sub 3}Cl{sub 16} structure. - Highlights: • High-quality Tl{sub 10}Hg{sub 3}Cl{sub 16} single crystal has been grown by Bridgman-Stockbarger method. • Electronic structure of Tl{sub 10}Hg{sub 3}Cl{sub 16} is studied by the XPS method. • Tl{sub 10}Hg{sub 3}Cl{sub 16} single crystal surface is sensitive with respect to Ar{sup +} ion

  13. Mujeres en la criminalidad: más preguntas que respuestas

    Directory of Open Access Journals (Sweden)

    Milcíades Vizcaíno Gutiérrez

    2010-06-01

    Full Text Available Problema. La mujer vinculada a actividades de criminalidad ha sido estudiada desde diferentes perspectivas. A pesar de los hallazgos, quedan preguntas por resolver. Una mirada panorámica indica vacíos, respuestas con escasa fundamentación teórica y metodológica, y conclusiones que reproducen sesgos culturales con repercusiones en la formulación de políticas públicas. Este avance de una investigación subraya algunos problemas que podrían abordarse en un país como Colombia, caracterizado por conflictos sin resolver. Método. Se hace una revisión de literatura secundaria, en la cual se identifican preguntas y respuestas de las que surgen perspectivas de tratamiento de nuevos problemas que pueden ser abordados mediante la investigación. Conclusiones. Se requiere más investigación para comprender facetas de la criminalidad en general, y específicamente de la participación femenina, en delitos de gran impacto social, que van desde asaltos a residencias, violencias contra ciudadanos en las calles y asesinatos, hasta la globalización del crimen representado en la narcoactividad, lavado de activos, tráfico de seres humanos y delitos informáticos.

  14. T-L Plane Abstraction-Based Energy-Efficient Real-Time Scheduling for Multi-Core Wireless Sensors

    Directory of Open Access Journals (Sweden)

    Youngmin Kim

    2016-07-01

    Full Text Available Energy efficiency is considered as a critical requirement for wireless sensor networks. As more wireless sensor nodes are equipped with multi-cores, there are emerging needs for energy-efficient real-time scheduling algorithms. The T-L plane-based scheme is known to be an optimal global scheduling technique for periodic real-time tasks on multi-cores. Unfortunately, there has been a scarcity of studies on extending T-L plane-based scheduling algorithms to exploit energy-saving techniques. In this paper, we propose a new T-L plane-based algorithm enabling energy-efficient real-time scheduling on multi-core sensor nodes with dynamic power management (DPM. Our approach addresses the overhead of processor mode transitions and reduces fragmentations of the idle time, which are inherent in T-L plane-based algorithms. Our experimental results show the effectiveness of the proposed algorithm compared to other energy-aware scheduling methods on T-L plane abstraction.

  15. Štúdium oneskoreného štiepenia po $\\beta$-rozpade v izotopoch $^{178-182}$Tl

    CERN Document Server

    Andel, Boris

    Topic of the thesis is $\\beta$-delayed fission. We describe nuclear fission, more specifically $\\beta$-delayed fission and its importance in the theoretical part of the thesis. We look briefly to four models of fission barriers (FRLDM, Thomas-Fermi, LSD and ETFSI model) and to $\\alpha$- and $\\beta$-decay of the nucleus. In the beginning of the experimental part of the thesis we describe ISOLDE facility at CERN and the detection setup of our experiment. In result part of the thesis, we are comparing models of fission barriers and analyzing data from the experiment IS466 –(2), which was undertook at ISOLDE. Four separate measurements were performed with the direct production of isotopes $^{178}$Tl, $^{180}$Tl, $^{182}$Tl and $^{202}$Fr. We evaluated delayed fission probabilities of produced isotopes $P_{βDF}\\,$($^{178}$Tl) = (2,8 ± 1,1)$\\times$10$^{-3}$, $P_{βDF}\\,$($^{180}$Tl) = (3,9 ± 1,1)$\\times$10$^{-5}$, $P_{βDF}\\,$($^{182}$Tl) < 1,4$\\times$10$^{-8}$ and $P_{βDF}\\,$($^{202}$Fr) = (2,1 ± 0,4)...

  16. 201Tl scintigraphic evaluation of tumor mass and viability of bone and soft-tissue tumors

    International Nuclear Information System (INIS)

    Tsuda, Takatoshi; Kubota, Masahiro; Yoshida, Satoru; Shibata, Masahito; Wakabayashi, Jun-ichi; Obata, Hiroyuki; Matsuyama, Toshikatsu; Usui, Masamichi; Ishii, Sei-ichi.

    1994-01-01

    To characterize 201 Tl uptake in patients with bone and soft-tissue tumor, we studied 49 patients with surgically proven tumors and one patient with a tumor diagnosed arteriographically. In 37 of our 50 patients, the tumor was evaluated with 201 Tl and arteriography. Moreover, in 14 of patients with pre-operative chemotherapy, pathologic changes were graded on the basis of percent tumor necrosis as defined histologically. The percent tumor necrosis histologically was compared with changes in the scintigraphic and conventional angiographic studies. Radiologic comparisons demonstrated a high degree of correlation with images of 201 Tl and both arterial and blood pool phase of 99m Tc-HMDP. Ninety-six percent of 28 malignant tumors had positive 201 Tl uptake. None of the patients showed any thallium accumulation in the soft tissues or skeleton adjacent to the lesion. Activity of 201 Tl was mainly dependent upon a tumor blood flow and a vascular density. In of 14 cases with the preoperative chemotherapeutic treatment, 201 Tl scintigraphic changes showed concordance with % tumor necrosis. Thallium-201 was superior to 99m Tc-HMDP in predicting tumor response to chemotherapy. Interestingly, delayed images of 99m Tc-HMDP of 5 responders with >90% tumor necrosis showed decreased uptake in the adjacent bone to the tumor mass lesions. It seems to be quite all right to consider that a major determinant of 201 Tl uptake is intratumoral angiogenecity, which is closely connected with tumor viability. Therefore, 201 Tl is a sensitive radiopharmaceutical for detection of vascular rich bone and soft-tissue tumors, and appears to be a simple and an accurate test for evaluating the response to specific therapeutic regimens of malignant bone and soft-tissue tumors. (author)

  17. Verification of imported food upon import for radiation processing: Dried herbs, including herbs used in food supplements, and spices by PSL and TL

    International Nuclear Information System (INIS)

    Boniglia, C.; Aureli, P.; Bortolin, E.; Onori, S.

    2009-01-01

    The Italian National Institute of Health in 2005-2006 performed an analytical survey of import on dried spices and herbs, including herbs used in food supplements, to investigate the entry in Italy of irradiated, and not correctly labelled, raw materials. In this survey, 52 samples, including nine herbal extracts, were collected. The method of photo-stimulated luminescence (PSL) was applied to all samples and only samples screened positive or intermediate with PSL were analysed by using the thermo-luminescence (TL) method. Out of the 12 samples screened positive or intermediate with PSL, the TL method confirmed irradiation of five samples (10% of the total assayed samples). One out of these five samples was a herbal supplement whereas three were herbal extracts that are known to be used as ingredients of herbal supplements, and another one was a spice.

  18. Verification of imported food upon import for radiation processing: Dried herbs, including herbs used in food supplements, and spices by PSL and TL

    Energy Technology Data Exchange (ETDEWEB)

    Boniglia, C. [Department of Veterinary Public Health and Food Safety, Istituto Superiore di Sanita, Rome (Italy)], E-mail: concetta.boniglia@iss.it; Aureli, P. [Department of Veterinary Public Health and Food Safety, Istituto Superiore di Sanita, Rome (Italy); Bortolin, E.; Onori, S. [Department of Technology and Health, Istituto Superiore di Sanita, Rome (Italy)

    2009-07-15

    The Italian National Institute of Health in 2005-2006 performed an analytical survey of import on dried spices and herbs, including herbs used in food supplements, to investigate the entry in Italy of irradiated, and not correctly labelled, raw materials. In this survey, 52 samples, including nine herbal extracts, were collected. The method of photo-stimulated luminescence (PSL) was applied to all samples and only samples screened positive or intermediate with PSL were analysed by using the thermo-luminescence (TL) method. Out of the 12 samples screened positive or intermediate with PSL, the TL method confirmed irradiation of five samples (10% of the total assayed samples). One out of these five samples was a herbal supplement whereas three were herbal extracts that are known to be used as ingredients of herbal supplements, and another one was a spice.

  19. A new method for crosstalk correction in simultaneous dual-isotope myocardial imaging with Tl-201 and I-123

    International Nuclear Information System (INIS)

    Tsuji, Akinori; Kojima, Akihiro; Oyama, Yoichi; Tomiguchi, Seiji; Kira, Tomohiro; Takagi, Yoshikazu; Shimomura, Osamu; Takahashi, Mutsumasa; Matsumoto, Masanori

    1999-01-01

    We have developed a new method of crosstalk correction in simultaneous dual-isotope imaging with Tl-201 and I-123 by using crosstalk ratios and a blurring filter. Single isotope myocardial studies (10 for Tl-201 and 7 for I-123) were performed with a dual energy window acquisition mode and two low energy general-purpose collimators. Then two planar images acquired with dual energy windows for a Tl-201 line source and an I-123 line source were obtained to measure line spread functions (LSFs) and crosstalk ratios for each image. The line source experiments showed that the LSFs for the Tl-201 imaging window from the single Tl-201 source were very similar to those for the I-123 imaging window from the single Tl-201 source, but the LSFs for the Tl-201 imaging window from the single I-123 source had broad shapes which differed from those for the I-123 imaging window from the single I-123. To obtain accurate I-123 crosstalk images in the Tl-201 imaging window from the I-123 images in the I-123 imaging window, we designed a low-pass blurring filter. In 7 clinical I-123 MIBG studies, I-123 window images processed with this filter became very similar to the Tl-201 window image from the single I-123 source. The method proposed in this study can accurately correct the crosstalk in dual isotope studies with Tl-201 and I-123 and is easily applicable to conventional gamma camera systems with any dual energy window acquisition mode. (author)

  20. Ag nanoparticle effects on the thermoluminescent properties of monoclinic ZrO2 exposed to ultraviolet and gamma radiation

    International Nuclear Information System (INIS)

    Villa-Sanchez, G; Mendoza-Anaya, D; Gutierrez-Wing, C; Perez-Hernandez, R; Gonzalez-MartInez, P R; Angeles-Chavez, C

    2007-01-01

    The goal of this work was to analyse ZrO 2 in the pure state and when doped with Ag nanoparticles, by electron microscopy, x-ray diffraction and thermoluminescence methods. According to the results obtained, Ag nanoparticles did not modify the morphology or the crystalline structure of the ZrO 2 . The thermoluminescent (TL) response of pure ZrO 2 showed two peaks, one at 334 K and the other at 417 K, when it was exposed to ultraviolet (UV) radiation, and at 342 and 397 K when gamma radiation was used. For ZrO 2 impregnated with Ag nanoparticles a diminished TL intensity due to nanoparticle shielding was observed, but the glow curve shape was similar. However, when Ag nanoparticles were added during the ZrO 2 synthesis, a shift of the TL peaks towards higher temperature values with reference to pure ZrO 2 was observed. A linear dependence of the integrated TL signal as a function of the irradiation dose was observed in all analysed samples. It was possible to determine some kinetic parameters, such as activation energy, kinetic order and frequency factor, using the sequential quadratic programming glow curve deconvolution; it was found that these values are highly dependent on the type of radiation used. Ag nanoparticles present in ZrO 2 also modified the kinetic parameters, mainly when they were added during the synthesis of ZrO 2 . Our results reinforce the possibilities of using pure and doped ZrO 2 as an appropriate dosimetric material in radiation physics

  1. Radiation damage in undoped CsI and CsI(Tl)

    International Nuclear Information System (INIS)

    Woody, C.L.; Kierstead, J.A.; Levy, P.W.; Stoll, S.

    1992-01-01

    Radiation damage has been studied in undoped CsI and CsI(TI) crystals using 60 Co gamma radiation for doses up to ∼ 4.2 x 10 6 . Samples from various manufacturers were measured ranging in size from 2.54 cm long cylinders to a 30 cm long block. Measurements were made on the change in optical transmission and scintillation light output as a function of dose. Although some samples showed a small change in transmission, a significant change in light output was observed for all samples. Recovery from damage was also studied as a function of time and exposure to UV light. A short lived phosphorescence was observed in undoped CsI, similar to the phosphorescence seen in CsI(TI)

  2. The precise measurement of TL isotopic compositions by MC-ICPMS: Application to the analysis of geological materials and meteorites.

    Science.gov (United States)

    Rehkämper, Mark; Halliday, Alex N.

    1999-07-01

    The precision of Tl isotopic measurements by thermal ionization mass spectrometry (TIMS) is severely limited by the fact that Tl possesses only two naturally occurring isotopes, such that there is no invariant isotope ratio that can be used to correct for instrumental mass discrimination. In this paper we describe new chemical and mass spectrometric techniques for the determination of Tl isotopic compositions at a level of precision hitherto unattained. Thallium is first separated from the geological matrix using a two-stage anion-exchange procedure. Thallium isotopic compositions are then determined by multiple-collector inductively coupled plasma-mass spectrometry with correction for mass discrimination using the known isotopic composition of Pb that is admixed to the sample solutions. With these procedures we achieve a precision of 0.01-0.02% for Tl isotope ratio measurements in geological samples and this is a factor of ≥3-4 better than the best published results by TIMS. However, without adequate precautions, experimental artifacts can be generated that result in apparent Tl isotopic fractionations of up to one per mil. Analysis of five terrestrial samples indicate the existence of Tl isotopic variations related to natural fractionation processes on the Earth. Two of the three igneous rocks analyzed in this study display Tl isotopic compositions indistinguishable from our laboratory standard, the reference material NIST-997 Tl. A third sample, however, is characterized by ɛ Tl ≈ 2.5 ± 1.5, where ɛ Tl represents the deviation of the 205Tl/ 203Tl ratio of the sample relative to NIST-997 Tl in parts per 10 4. Even larger deviations were identified for two ferromanganese crusts from the Pacific Ocean, which display ɛ Tl-values of +5.0 ± 1.5 and +11.7 ± 1.3. We suggest that the large variability of Tl isotopic compositions in the latter samples are caused by low-temperature processes related to the formation of the Fe-Mn crusts by precipitation and

  3. Preparation of CaSO4:Dy by precipitation method to gamma radiation dosimetry

    International Nuclear Information System (INIS)

    Rivera, T.; Roman, J.; Azorin, J.; Sosa, R.; Guzman, J.; Serrano, A.K.; Garcia, M.; Alarcon, G.

    2010-01-01

    This paper presents the results of the preparation and characterization of dysprosium-doped calcium sulfate (CaSO 4 :Dy) phosphor, which was obtained by homogeneous precipitation from calcium acetate Ca(CH 3 COO - ) 2 . Structural and morphological characteristics were studied using a scanning electronic microscope (SEM). The structure of all compounds was determined by X-ray diffraction method too. Thermoluminescence (TL) emission properties of CaSO 4 :Dy under gamma radiation effects were studied. This phosphor powder presented a TL glow curve with two peaks (Tmax) centered at around of 180 and 300 deg. C, respectively. The TL response of CaSO 4 :Dy as a function of gamma absorbed dose was linear in a wide range. Both emission and excitation spectra were also obtained. Results showed that this new preparation method of CaSO 4 :Dy TL phosphor is less expensive, cleaner and safer than the conventional preparation method.

  4. Environmental gamma radiation monitoring at Visakhapatnam using thermoluminescence dosimeters

    International Nuclear Information System (INIS)

    Swarnkar, M.; Sahu, S.K.; Takale, R.A.; Shetty, P.G.; Pundit, G.G.; Puranik, V.D.

    2012-01-01

    The gamma rays are the most significant part of environmental dose due to its large range and deep penetrating power. The environmental gamma radiation is mainly originated from two sources natural radiation and artificially produced radiation. The natural radiation dose arises from the cosmic radiation (galactic and solar) and from the Earth (terrestrial) surface. In the last few decades there is a growing concern all over the world about radiation and their exposure to population. Thus it is necessary to conduct radiological environmental surveillance. The radiation survey data are useful to establish the natural background gamma radiation levels. Extensive gamma radiation survey was carried out around the surroundings of Vishakhapatnam using Thermoluminescence Dosimeters (TLDs). The CaSO 4 :(0.2 mole %) Dy Teflon TLD discs, specifically designed for environmental gamma radiation monitoring purpose were used. These TLD badge are having very high TL sensitivity, a negligible fading rate and a stable TL response. TLDs were deployed on quarterly basis for two years to obtain the cumulative gamma background radiation levels in the study area. The radiological survey was also carried out by using a calibrated radiation survey meter. The annual dose rates were computed from quarterly values actually found and normalised to 365 days. The environmental gamma radiation levels around Vishakhapatnam were found to be in the range of 0.79 mGy/y to 1.86 mGy/y. It is clearly seen from the results that location to location there is a large variation in external gamma radiation levels. During the cycle of the TLD survey, spot readings of the background radiation levels were taken, both while placing the TLDs and while removing them. The instantaneous dose rates measured using survey meter, are also following the large variation as found in TLDs. It varies between 110 nGy/hr to 210 nGy/hr. (author)

  5. Exploration of GaInTlP and related Tl-containing III-V alloys for photovoltaics

    International Nuclear Information System (INIS)

    Friedman, D. J.; Kurtz, Sarah R.; Kibbler, A. E.

    1999-01-01

    This paper discusses the results of an attempt to grow GaInTlP for application as a 1-eV material for the third junction of a GaInP/GaAs/3rd-junction high-efficiency solar cell. Although early indications from the literature were promising, we are unable to produce crystalline homogeneous material, and so we conclude that this material is not a promising candidate for such applications as photovoltaics

  6. Myocardial 201Tl washout after combined dipyridamole submaximal exercise stress: Reference values from different patient groups

    International Nuclear Information System (INIS)

    Fridrich, L.

    1989-01-01

    Dipyridamole stress is favorable in patients unable to exercise maximally for 201 Tl myocardial scintigraphy. Aside from an analysis of uptake defects, proper washout analysis can be limited by heart rate variations when isolated dipyridamole stress is used. Heart rate standardized 201 Tl washout kinetics after a combined dipyridamole and submaximal exercise stress protocol (CDSE), feasible in elderly patients as well as in patients with peripheral artery disease, were therefore studied to investigate the 201 Tl washout after CDSE in differently defined patient groups: Group I comprised 19 patients with documented heart disease and angiographically excluded coronary artery disease (CAD); group II contained 17 patients with a very low likelihood of CAD determined by both normal exercise radionuclide ventriculography and normal 201 Tl uptake. Group III comprised 56 patients with a 50% pretest likelihood of CAD but normal 201 Tl uptake. Mean washout values were nearly identical in all groups. Despite similar uptake patterns, however, washout standardized by CDSE was significantly lower than the normal washout values after maximal treadmill exercise. Thus an obviously lower 201 Tl washout after CDSE than after maximal treadmill exercise must be considered if washout analysis criteria after dipyridamole are applied to evaluate ischemic heart disease. Nevertheless, heart rate elevation achieved by additional submaximal exercise stress seems necessary, adequate and clinically safe for standardisation of washout analysis in dipyridamole 201 Tl scintigraphy. (orig.)

  7. Significance of Tl-201 redistribution on infarcted region assessed by coronary sinus flow and lactate metabolism

    International Nuclear Information System (INIS)

    Mori, Takao; Yamabe, Hiroshi; Suda, Kenichirou; Ohnishi, Masataka; Shiotani, Hideyuki; Kurimoto, Yasuyuki; Kobayashi, Katsuya; Maeda, Kazumi; Fukuzaki, Hisashi

    1987-01-01

    To clarify the significance of Tl-201 redistribution on infarcted regions, coronary sinus and great cardiac vein flow response and lactate metabolism assessed by Webster catheter on 14 infarcted regions after dipyridamole administration were compared with Tl-201 redistribution phenomenon. The regional coronary flow response and lactate extraction ratio in 11 regions with Tl-201 redistribution were lower than those in 3 regions without Tl-201 redistribution. Only 5 regions in 11 with Tl-201 redistribution showed lactate production. The coronary flow response in 5 regions with lactate production was not different from those in 6 without lactate production (1.16 ± 0.89 vs. 1.47 ± 0.67; n.s.). The degree of Tl-201 redistribution assessed by relative activity was not different between regions with and without lactate production. The left ventricular end-diastolic pressure elevated in 5 regions with lactate production (17.8 ± 5.4 mmHg to 29.6 ± 4.9 mmHg; p < 0.05), but didn't in 6 regions without lactate production. Five regions with lactate production contained 4 hypokinetic regions, on the other hand 6 regions without lactate production contained only 3 hypokinetic regions. In conclusion, Tl-201 redistribution on infarcted region revealed not only ischemia but also decreased coronary flow response without lactate production and/or left ventricular dysfunction. (author)

  8. TL and OSL studies of carbon doped magnesium aluminate (MgAl2O4:C)

    Science.gov (United States)

    Raj, Sanu S.; Mishra, D. R.; Soni, Anuj; Grover, V.; Polymeris, G. S.; Muthe, K. P.; Jha, S. K.; Tyagi, A. K.

    2016-10-01

    The MgAl2O4:C has been synthesized by using two different methods by electron gun and vacuum assisted melting of MgAl2O4 in presence of graphite. The MgAl2O4:C phosphor thus developed by these two different methods have similar types of the TL/OSL defects with multiple overlapping TL glow peaks from 100 °C to 400 °C. The Computerized Curve De-convolution Analysis (CCDA) has been used to measure TL parameters such as thermal trap depth, frequency factor and order of kinetic associated with charge transfer process in TL phenomenon. The investigated TL/OSL results show that these two methods of incorporating carbon in MgAl2O4 have generated closely resemble the defects of similar types in MgAl2O4:C lattice. However, the MgAl2O4:C synthesized by electron gun shows relatively larger concentration of the TL/OSL defects as compared to MgAl2O4:C synthesized using vacuum assisted melting method. The photo-ionization cross-section (PIC) associated with fastest OSL component of MgAl2O4: C is found to be ∼ 0.5 times than that of fastest OSL component of commercially available dosimetric grade α-Al2O3:C. The MgAl2O4:C thus developed shows good dynamic OSL dose linearity from few mGy to 1 Gy. This work reveals that MgAl2O4:C could be developed as potential tissue equivalent OSL / TL material.

  9. Thermoluminescent monitoring of the solar ultraviolet radiation with KCl: Eu2+ crystals

    International Nuclear Information System (INIS)

    Chernov, V.; Melendrez, R.; Barboza F, M.

    2000-01-01

    In this work it has been investigating the Tl properties of KCl: Eu 2+ subjected to solar direct radiation. Also it was realized irradiation with the Deuterium and Xenon lamps. It was used a set of filters and a Katos monochromator 0.25 M to determine the spectral response to Tl peaks and a study of them with respect to the duration of the Sun irradiation. After of the Sun irradiation the Tl curves show several peaks between the ambient temperature and 673 K. The relation between peaks depends strongly of the irradiation time and the different solar light wavelength. It is possible to divide the Tl peaks in two groups. The first one (T 473 K) is not too sensitive but is more stable under optical whitening. Here the obtained results are discussed with respect to UV dosemeters development for environment which facilitate to obtain direct measurements of the UV index. (Author)

  10. Experimental study on the CsI (Tl) crystal anti-compton detector in CDEX

    International Nuclear Information System (INIS)

    Liu Shukui; Yue Qian; Tang Changjian

    2012-01-01

    CDEX (China Dark matter Experiment) Collaboration will carry out direct search for dark matter with Ultra-Low Energy Threshold High Purity germanium (ULE-HPGe) detector at CJPL (China Jinping deep underground Laboratory). Before underground research, some experiments of the CsI (Tl) crystal Anti-Compton detector have been done on the ground, including light guide choice, wrapping material choice, height uniformity of CsI (Tl) crystal, side uniformity of CsI (Tl) crystal and the test results of all the crystals. Through the preliminary work on the ground, we have got some knowledge of the anti-compton detector and prepared for the underground experiment. (authors)

  11. Magnetic measurements on Tl-2212 and Bi-2212 single crystals: a comparative study

    International Nuclear Information System (INIS)

    Oussena, M.; Porter, S.; Volkozub, A.; De Groot, P.A.J.; Lanchester, P.C.; Ogborne, D.; Weller, M.T.; Balakrishnan, G.; Paul, D.McK.

    1994-01-01

    We have compared the magnetic behaviour of two identically shaped single crystals, Tl 2 Ba 2 CaCu 2 O 8 and Bi 2 Sr 2 CaCu 2 O 8 . The critical current density is found to decrease more rapidly with temperature in Bi-2212 although it is the highest in this material at low temperatures (T < 10K). I-V characteristic curves have been obtained from measurements of magnetic sweep rate dependencies of the hysteresis loops. We have found that the characteristic temperature at which flux motion becomes important is significantly higher in Tl-2212 than in Bi-2212. Hence the Tl-2212 has a larger effective pinning. (orig.)

  12. Radiation Shielding Properties of Some Marbles in Turkey

    Science.gov (United States)

    Günoǧlu, K.; Akkurt, I.

    2011-12-01

    Especially after development of technology, radiation started to be used in a large fields such as medicine, industry and energy. Using radiation in those fields bring hazordous effect of radition into humancell. Thus radiation protection becomes important in physics. Although there are three ways for radiation protection, shielding of the radiation is the most commonly used method. Natural Stones such as marble is used as construction material especially in critical building and thus its radiation shielding capability should be determined. In this study, gamma ray shielding properties of some different types of marble mined in Turkey, have been measured using a NaI(Tl) scintillator detector. The measured results were also compared with the theoretical calculations XCOM.

  13. Reactivity and stability of thallium oxide for fabricating TlSnZnO toward thin-film transistors with high mobility

    Energy Technology Data Exchange (ETDEWEB)

    Kishimoto, Katsushi [Graduate School of Materials Science, Nara Institute of Science and Technology, Nara, 630-0192 (Japan); Nose, Yoshitaro [Department of Materials Science and Engineering, Kyoto University, Kyoto, 606-8501 (Japan); Ishikawa, Yasuaki, E-mail: yishikawa@ms.naist.jp [Graduate School of Materials Science, Nara Institute of Science and Technology, Nara, 630-0192 (Japan); Fujii, Mami N.; Uraoka, Yukiharu [Graduate School of Materials Science, Nara Institute of Science and Technology, Nara, 630-0192 (Japan)

    2016-07-05

    Thermal reaction between thallium oxide (Tl{sub 2}O{sub 3}) and zinc oxide (ZnO), tin oxide (SnO{sub 2}) or indium oxide (In{sub 2}O{sub 3}) annealed at 600 °C for 18 h in the air atmosphere was investigated. From XRD results of 600 °C annealed samples, Tl{sub 2}O{sub 3} had the biggest reactivity compared with ZnO. The EDX results suggest the mechanism in which the thallium atoms scattered and attached uniformly only on ZnO particles. We also analyzed XPS data to compare O 1s bond and Tl 4f bond of as-mixed samples with that of annealed samples, and found that Zn and Sn can contribute in improving Tl and O bonding stability. However, the affinity of In for Tl is weaker than that of Zn or Sn. Finally, we prepared the samples mixed with ZnO, SnO{sub 2}, and Tl{sub 2}O{sub 3} powder and the samples mixed with Zn{sub 2}SnO{sub 4} and Tl{sub 2}O{sub 3} powder annealed at 600 °C for 18 h. Results show that Zn{sub 2}SnO{sub 4} has the same or more reactivity than SnO{sub 2} and ZnO mixed particle despite of the more stable and sufficient dispersion of Zn and Sn atoms. More stable TlSnZnO can be fabricated from Zn{sub 2}SnO{sub 4} + Tl{sub 2}O{sub 3} powder by suitable thermal processes. It is expected that TlSnZnO sputtering target can be fabricated by suitable calcination. - Highlights: • Thermal reaction of Tl{sub 2}O{sub 3} and ZnO, SnO or In{sub 2}O{sub 3} were investigate. • It is found that Tl{sub 2}O{sub 3} is reactive with ZnO rather than SnO or In{sub 2}O{sub 3}. • Two-step annealing process is promising route for forming TlSnZnO tablet.

  14. Discordant Tl-201 and Tc-99m imaging in a patient with thyroid carcinoma and Hashimoto's disease

    International Nuclear Information System (INIS)

    Morita, S.; Ishibashi, M.; Hirayama, T.; Kumabe, T.; Ohtake, H.

    1990-01-01

    In a case of Hashimoto's disease complicated by thyroid gland cancer, the primary site of the cancer was visualized as a cold nodule on Tc-99m pertechnetate scintigraphy, as a warm nodule on Tl-201 early imaging, and as a hot nodule on Tl-201 delayed imaging. Generally, Tl-201 shows markedly diffuse accumulation in the lesions of Hashimoto's disease. The warm nodules observed on early scans suggested similar accumulation at the sites of Hashimoto's disease and thyroid cancer. The hot nodules on delayed imaging may be due to the difference in Tl-201 washout time between the sites of Hashimoto's disease and thyroid cancer. There was markedly increased Tl-201 accumulation in bilateral cervical metastatic lymph nodes on both early and delayed images

  15. Study of LiF:Mg,Ti and CaSO4:Dy dosimeters TL response to electron beams of 6 MeV applied to radiotherapy using PMMA and solid water phantoms

    International Nuclear Information System (INIS)

    Bravim, A.; Sakuraba, R.K.; Cruz, J.C.; Campos, L.L.

    2011-01-01

    The performance of CaSO 4 :Dy and LiF:Mg,Ti dosimeters to electron beams applied to radiotherapy was investigated. The TL response of these dosimeters was studied for 6 MeV electron beams using PMMA and Solid Water (SW) phantoms. The dosimeters were previously separated in groups according to their TL individual sensitivities to 60 Co gamma-radiation in air under electronic equilibrium conditions. After that, they were irradiated with 6 MeV electron doses of 0.1, 0.5, 1, 5 and 10 Gy using a linear accelerator Clinac 2100C Varian of Hospital Israelita Albert Einstein – HIAE. The electron beam irradiations were performed using a 10 × 10 cm 2 field size, 100 cm source-phantom surface distance and the dosimeters were positioned at the depth of maximum dose (1.2 cm). The TL readings were carried out between 24 and 32 h after irradiation using a Harshaw 3500 TL reader. The TL dose–response of both type of dosimeters and phantoms presented linear behavior on the electron dose range from 0.1 to 5 Gy CaSO 4 :Dy dosimeter is 21 times more sensitive than LiF:Mg,Ti, dosimeter commonly used in clinical dosimetry. The obtained results indicate that the performance of CaSO 4 :Dy dosimeters is similar to LiF:Mg,Ti dosimeters and this material can be an alternative dosimetric material to be used to clinical electron beams dosimetry.

  16. Core breaking and octupole low-spin states in $^{207}$ Tl

    CERN Multimedia

    We propose to study the low-spin level structure of the $^{207}$Tl nucleus populated by the $\\beta$- decay of $^{207}$Hg. While $^{207}$Tl is a single-proton hole nucleus, the majority of the observed states will have a three-particle structure thus requiring the breaking of the neutron or proton core, or a collective octupole phonon coupled to the single proton hole. Thus information will be obtained on the single particle orbitals in the vicinity of the N=126 and Z=82 magic numbers, and on the size of the shell gap. The results will be used to improve the predictive power of the shell model for more exotic nuclei as we move to lighter N=126 nuclei.The experiment will use the ISOLDE Decay station, and will take advantage of the $^{207}$Hg beam from the molten lead target. A test on the feasibility to produce an $^{208}$Hg beam from the same target, with the aim to study the $\\beta$-decay into $^{208}$Tl, could be performed at the same time.

  17. Effect of the route of administration on the biodistribution of radioiodinated OV-TL 3 F(ab')2 in experimental ovarian cancer

    International Nuclear Information System (INIS)

    Tibben, J.G.; Massuger, L.F.A.G.; Boerman, O.C.; Borm, G.F.; Claessens, R.A.M.J.; Corstens, F.H.M.

    1994-01-01

    The effect of the route administration on the distribution of radioiodinated OV-TL 3 F(ab') 2 was studied in Balb/c female mice with intraperitoneal or subcutaneous ovarian carcinoma xenografts. In the intraperitoneal tumour model in which both ascites and solid tumour deposits were present, intraperitoneal administration resulted in a lower estimated radiation dose to blood as compared with intravenous administration. In this model normalization to equal estimated radiation doses to blood for both routes of administration indicated that a twice as high estimated radiation dose can be guided to solid intraperitoneal tumour deposits following intraperitoneal administration. Evacuation of ascitic tumour cells prior to monoclonal antibody injection further increased the estimated radiation dose to solid intraperitoneal tumour deposits following intraperitoneal delivery. Following simultaneous intravenous and intraperitoneal injection of the monoclonal antibody, tissue uptake showed no relevant differences in the subcutaneous tumour model. Overall, the intraperitoneal route of administration was found to be the best choice for therapeutic delivery of iodine-131 labelled monoclonal antibodies. (orig.)

  18. Efecto de un curso de relación de ayuda sobre la elección de respuesta espontánea e identificación de respuesta empática en alumnos de enfermería Effect of a counseling course on the choice of spontaneous response and empathetic response identification by nursury students

    Directory of Open Access Journals (Sweden)

    José Carlos Bermejo Higuera

    2012-03-01

    Full Text Available Objetivos: determinar la tendencia de respuesta espontánea de alumnos de Enfermería ante situaciones simuladas de conflicto emocional antes y después de cursar una asignatura de relación de ayuda. Método: estudio cuasiexperimental pretest-postest en un grupo de 78 estudiantes de enfermería. Se aplicó un ejercicio de elección de respuesta espontánea antes y después de cursar una asignatura de relación de ayuda. Cincuenta estudiantes participaron en el pretest y 75 en el postest. Se evaluó la elección de respuesta entre seis tipos a elegir. Como contraste de medias prueba T para muestras relacionadas e independientes. Chi cuadrado para observar las distribuciones de elección de respuesta; intervalo de confianza 95%. Resultados: antes del curso eligieron espontáneamente la respuesta empática en el 9% de las ocasiones, mientras que al acabar el curso lo hicieron en el 43% de las ocasiones. El 33% de respuesta de apoyo-consuelo inicial disminuyó a 10%; el 30% de respuestas de solución de problema inicial disminuyó a 19%; el 18% de respuestas de valoración o juicio moral inicial disminuyó a 11%; el 8% de respuestas de investigación aumentó a 12%; medias estadísticamente significativas entre sus diferencias pre y postest. Se observaron pequeñas diferencias de género. Conclusiones: Los resultados apuntan a la validez de la formación en relación de ayuda para el aprendizaje de la respuesta empática.Objective: to determine spontaneous response tendency in emotionally conflictive simulated situations by nursery students before and after attending a counseling subject. Method: pretest-posttest cuasiexperimental study with a group of 78 nursing students. They were applied a spontaneous response choice test before and after studying a subject on counseling. There were 50 participants that answered the pre-test and 75 the post-test. The answer choice out of 6 posibilities was evaluated. T test was performed for related samples and

  19. The formation of radiation defects in monohydrate of lithium sulfate

    International Nuclear Information System (INIS)

    Bahytzhan, A.B.; Zhussupov, A.A.; Kim, L.M.

    2005-01-01

    Full text: The crystals of lithium sulfate are monohydrate. At heating it pass waterless form. This crystals are represented the convenient for study of the crystal water influence on the radiation-induced processes. After irradiation in Li 2 SO 4 · H 2 O it was established the radicals SO 3 - and SO 4 - by the EPR method. The similar radiation induced centres are characteristic for the all sulphates. We established that at after irradiation by X-rays monohydrate sulphate lithium have not the absorption bands in a range 200-800 nm. It complicates study of the given systems. The dominant peak of recombination luminescence (TL) has a maximum in area 100 K. On its high-temperature wing there is 'shoulder' showing of more high-temperature and weak luminescence. At higher temperatures some very weak of TL peaks are observed. The dehydration of the samples does not essential influence for this weak TL. Because we have concentrated the basic attention only on low temperature peaks of recombination luminescence. The TL peak of a luminescence with a maximum at 100 K as a result of thermo treatment has disappeared. Dominant emission became the TL peak with a maximum at 130 K. It is necessary to note, that after dehydration the radiative sensitivity of sulphate lithium sharply has increased. Our rough estimation for this change give value almost two orders. In monohydrate the maximum of TL peak is observed at 130 K radiation by UV. This peak can be divided into two peaks with maximums at 100 K and 130 K. At an irradiation dehydrated samples by ultraviolet light the TL peaks are not observed. The given results allow connecting a luminescence at 100 K with disintegration of defects in the subsystem of crystal water. The products radiolysis of water molecules essential influence on recombination processes in sulphate subsystem. The one hand they suppress them, with another - there is a new channel of disintegration complex anions. It is established that photoconductivity of the

  20. Factores moduladores de la respuesta agresiva tras la exposición a videojuegos violentos

    Directory of Open Access Journals (Sweden)

    Alejandro de la Torre-Luque

    2013-05-01

    Full Text Available En ciertas situaciones se ha asociado la influencia de los video-juegos violentos con las conductas agresivas y/o delictivas. El presente estudio pretende destacar un efecto de la exposición a un videojuego violento de coches sobre la elicitación a corto plazo, en las respuestas de agresión e ira tras la exposición. Para ello, 47 adolescentes fueron expuestos al video-juego violento y a uno no violento durante 30 minutos. Se midieron ansiedad e ira autoinformadas pre-postest, así como la ejecución en una tarea indirecta de agresión. Se halló un efecto principal de la edad y de interacción de ésta con el tipo de videojuego y el sexo. Asimismo, se halló un efecto pre-postest en ira estado tras la exposición al videojuego violento. Por otro lado, se encontró un modelo predictor para la ejecución de la respuesta agresiva tras la presentación del videojuego violento con la edad e ira pre-exposición como factores. En conclusión, se destaca un efecto de priming de la ira a corto plazo y la edad tras la exposición al videojuego violento, en la respuesta agresiva. La presencia de moduladores de los efectos de contenidos violentos puede esclarecer su naturaleza y ayudar a predecir conductas delictivas.