WorldWideScience

Sample records for radiation portal monnitoring

  1. Radiation portal evaluation parameters

    International Nuclear Information System (INIS)

    York, R.L.

    1998-01-01

    The detection of the unauthorized movement of radioactive materials is one of the most effective nonproliferation measures. Automatic special nuclear material (SNM) portal monitors are designed to detect this unauthorized movement and are an important part of the safeguard systems at US nuclear facilities. SNM portals differ from contamination monitors because they are designed to have high sensitivity for the low energy gamma-rays associated with highly enriched uranium (HEU) and plutonium. These instruments are now being installed at international borders to prevent the spread of radioactive contamination an SNM. In this paper the parameters important to evaluating radiation portal monitors are discussed. (author)

  2. Uzbekistan Radiation Portal Monitoring System

    International Nuclear Information System (INIS)

    Richardson, J; Knapp, R; Loshak, A; Yuldashev, B; Petrenko, V

    2005-01-01

    The work proposed in this presentation builds on the foundation set by the DTRA funded demonstration project begun in 2000 and completed in December of 2003. This previous work consisted of two phases whose overall objective was to install portal radiation monitors at four select ports-of-entry in Uzbekistan (Tashkent International Airport, Gisht-Kuprik (Kazakhstan border), Alat (Turkmenistan border), and Termez (Afghanistan border)) in order to demonstrate their effectiveness in preventing the illicit trafficking of nuclear materials. The objectives also included developing and demonstrating capabilities in the design, installation, operation, training, and maintenance of a radiation portal monitoring system. The system and demonstration project has proved successful in many ways. An effective working relationship among the Uzbekistan Customs Services, Uzbekistan Border Guards, and Uzbekistan Institute of Nuclear Physics has been developed. There has been unprecedented openness with the sharing of portal monitor data with Lawrence Livermore National Laboratory. The system has proved to be effective, with detection of illicit trafficking, and, at Alat, an arrest of three persons illegally transporting radioactive materials into Turkmenistan. The demonstration project has made Uzbekistan a model nonproliferation state in Central Asia and, with an expanded program, places them in a position to seal a likely transit route for illicit nuclear materials. These results will be described. In addition, this work is currently being expanded to include additional ports-of-entry in Uzbekistan. The process for deciding on which additional ports-of-entry to equip will also be described

  3. Increase in Efficiency of Use of Pedestrian Radiation Portal Monitors

    Science.gov (United States)

    Solovev, D. B.; Merkusheva, A. E.

    2017-11-01

    Most international airports in the world use radiation portal monitors (RPM) for primary radiation control organization. During the exploitation pedestrian radiation portal monitors operators (in the Russian Federation it is a special subdivision of customs officials) have certain problems related to the search of an ionizing radiation source causing the alarm signal of a radiation monitor. Radiation portal monitors at standard (factory) settings have to find out the illegal moving of the radioisotopes moved by physical persons passing through a controlled zone and having a steady radiation by the gamma or neutron channel. The problem is that recently the number of the ownerships who underwent treatment or medical diagnostics with the use of radio pharmaceuticals considerably increased, i.e,. ownerships represent such an ionizing radiation source. The operator of the radiation portal monitor has to define very quickly whether the ownership is a violator (takes unsolved radioisotopes illegally) or is just a patient of the clinic who underwent treatment/diagnostics with the use of radio pharmaceuticals. The research showing the radioisotopes which are most often used in the medical purposes are given in article, it is offered to use the new software developed by the authors allowing the operator of the radiation portal monitor to define the location of the ownership which has such ionizing radiation source by the activity of radiation similar to the radiation from radio pharmaceuticals.

  4. Adobe Photoshop images software in the verification of radiation portal

    International Nuclear Information System (INIS)

    Ouyang Shuigen; Wang Xiaohu; Liu Zhiqiang; Wei Xiyi; Qi Yong

    2010-01-01

    Objective: To investigate the value of Adobe Photoshop images software in the verification of radiation portal. Methods: The portal and simulation films or CT reconstruction images were imported into computer using a scanner. The image size, gray scale and contrast scale were adjusted with Adobe Photoshop images software, then image registration and measurement were completed. Results: By the comparison between portal image and simulation image, the set-up errors in right-left, superior-inferior and anterior-posterior directions were (1.11 ± 1.37) mm, (1.33 ± 1.25) mm and (0.83±0.79) mm in the head and neck;(1.44±1.03) mm,(1.6±1.52) mm and (1.34±1.17) mm in the thorax;(1.53±0.86) mm, (1.83 ± 1.19) mm and (1.67 ± 0.68)mm in the abdomen; (1.93 ± I. 83) mm, (1.59 ± 1.07)mm and (0.85 ± 0.72)mm in the pelvic cavity. Conclusions: Accurate radiation portal verification and position measurement can be completed by using Adobe Photoshop, which is a simple, safe and reliable method. (authors)

  5. Impact of spectral smoothing on gamma radiation portal alarm probabilities

    International Nuclear Information System (INIS)

    Burr, T.; Hamada, M.; Hengartner, N.

    2011-01-01

    Gamma detector counts are included in radiation portal monitors (RPM) to screen for illicit nuclear material. Gamma counts are sometimes smoothed to reduce variance in the estimated underlying true mean count rate, which is the 'signal' in our context. Smoothing reduces total error variance in the estimated signal if the bias that smoothing introduces is more than offset by the variance reduction. An empirical RPM study for vehicle screening applications is presented for unsmoothed and smoothed gamma counts in low-resolution plastic scintillator detectors and in medium-resolution NaI detectors. - Highlights: → We evaluate options for smoothing counts from gamma detectors deployed for portal monitoring. → A new multiplicative bias correction (MBC) is shown to reduce bias in peak and valley regions. → Performance is measured using mean squared error and detection probabilities for sources. → Smoothing with the MBC improves detection probabilities and the mean squared error.

  6. Development of the image registration program for portal and DRR images in radiation therapy

    International Nuclear Information System (INIS)

    Watanabe, Hiroyuki; Ito, Takeshi; Nakazeko, Kazuma; Tachibana, Atsuhi; Hashimoto, Takeyuki; Shinohara, Hiroyuki

    2012-01-01

    In this article, the authors propose an image registration program of portal images and digitally reconstructed radiography (DRR) images used as simulation images for external beam radiation therapy planning. First, the center of the radiation field in a portal image taken using a computed radiograhy cassette is matched to the center of the portal image. Then scale points projected on a DRR image and the portal image are deleted, and the portal image with the radiation field is extracted. Registration of the DRR and portal images is performed using mutual information as the registration criterion. It was found that the absolute displacement misregistrations in two directions (x, y) were 1.2±0.7 mm and 0.5±0.3 mm, respectively, and rotation disagreement about the z axis 0.3±0.3deg. It was concluded the proposed method was applicable to image registration of portal and DRR images in radiation therapy. (author)

  7. A theoretical approach to calibrate radiation portal monitor (RPM) systems

    International Nuclear Information System (INIS)

    Nafee, Sherif S.; Abbas, Mahmoud I.

    2008-01-01

    Radiation portal monitor (RPM) systems are widely used at international border crossings, where they are applied to the task of detecting nuclear devices, special nuclear material, and radiation dispersal device materials that could appear at borders. The requirements and constraints on RPM systems deployed at high-volume border crossings are significantly different from those at weapons facilities or steel recycling plants, the former being required to rapidly detect localized sources of radiation with a very high detection probability and low false-alarm rate, while screening all of the traffic without impeding the flow of commerce [Chambers, W.H., Atwater, H.F., Fehlau, P.E., Hastings, R.D., Henry, C.N., Kunz, W.E., Sampson, T.E., Whittlesey, T.H., Worth, G.M., 1974. Portal Monitor for Diversion Safeguards. LA-5681, Los Alamos Scientific Laboratory, Los Alamos, NM]. In the present work, compact analytical formulae are derived and used to calibrate two RPM systems with isotropic radiating sources: (i) polyvinyltoluene (PVT) or plastic and (ii) thallium-doped crystalline sodium iodide, NaI(Tl), gamma-ray detector materials. The calculated efficiencies are compared to measured values reported in the literatures, showing very good agreement

  8. A radiation-tolerant electronic readout system for portal imaging

    Science.gov (United States)

    Östling, J.; Brahme, A.; Danielsson, M.; Iacobaeus, C.; Peskov, V.

    2004-06-01

    A new electronic portal imaging device, EPID, is under development at the Karolinska Institutet and the Royal Institute of Technology. Due to considerable demands on radiation tolerance in the radiotherapy environment, a dedicated electronic readout system has been designed. The most interesting aspect of the readout system is that it allows to read out ˜1000 pixels in parallel, with all electronics placed outside the radiation beam—making the detector more radiation resistant. In this work we are presenting the function of a small prototype (6×100 pixels) of the electronic readout board that has been tested. Tests were made with continuous X-rays (10-60 keV) and with α particles. The results show that, without using an optimised gas mixture and with an early prototype only, the electronic readout system still works very well.

  9. The specialized portals in the knowledge transfer systems: the ionizing radiation portal http://www.ionizantes.ciemat.es/

    International Nuclear Information System (INIS)

    Arboli, M. Marco; Hernanz, Oscar; Couchoud Gregory, Milagros

    2008-01-01

    Full text: This paper shows the new infrastructure to disseminate RP knowledge and information developed by the community involved in radiation uses. The www.ionizantes.ciemat.es portal has been implemented by CIEMAT and CINDOC- CSIC with the support of the national and international organizations related to the radiation applications. The design and structure of the databases was developed by CIEMAT and CINDOC-CSIC using the experience acquired by both organizations in the knowledge transfer. The initiative aims to establish collaboration with the sector involved in the most important applications of the ionizing radiation uses. The goal is to share resources establishing a new system of information between the experts, researchers and public. The portal also brings the dialogue to the entire sector and provides details of the relevant research projects. The main specific objectives of this portal are: a) To inform about the new projects developed; b) To download publications, reports and papers; c) to learn more about ionizing radiation; d) To promote collaborative knowledge transfer. The portal shows particular relevance to representative international and national organizations, the private sector and the local community relevant organizations. Results: The resources include in the database of the portal are: the agenda, documents, research calls, legislation, research projects, most important journals and summaries, patents and other available tools. The information is presented in a categorized and classified structure. This virtual community offers better knowledge transfer. It also optimizes the communication and research dissemination to the society. (author)

  10. An inverse source location algorithm for radiation portal monitor applications

    International Nuclear Information System (INIS)

    Miller, Karen A.; Charlton, William S.

    2010-01-01

    Radiation portal monitors are being deployed at border crossings throughout the world to prevent the smuggling of nuclear and radiological materials; however, a tension exists between security and the free-flow of commerce. Delays at ports-of-entry have major economic implications, so it is imperative to minimize portal monitor screening time. We have developed an algorithm to locate a radioactive source using a distributed array of detectors, specifically for use at border crossings. To locate the source, we formulated an optimization problem where the objective function describes the least-squares difference between the actual and predicted detector measurements. The predicted measurements are calculated by solving the 3-D deterministic neutron transport equation given an estimated source position. The source position is updated using the steepest descent method, where the gradient of the objective function with respect to the source position is calculated using adjoint transport calculations. If the objective function is smaller than the convergence criterion, then the source position has been identified. This paper presents the derivation of the underlying equations in the algorithm as well as several computational test cases used to characterize its accuracy.

  11. Standardisation of radiation portal monitor controls and readouts

    International Nuclear Information System (INIS)

    Tinker, Michael R.

    2010-01-01

    There is an urgent need to standardise the numbering configuration of radiation portal monitor sensing panels. Currently, manufacturers use conflicting numbering schemes that may confuse operators of these varied systems. There is a similar problem encountered with the varied choices of colored indicator lights and colored print lines designated for gamma and neutron alarms. In addition, second-party software that changes the alarm color scheme may also have been installed. Furthermore, no provision exists for the color blind or to provide work stations with only black ink on alarm printouts. These inconsistencies and confusing setups could inadvertently cause a misinterpretation of the alarm, resulting in the potential release of a radiological hazard into a sovereign country. These issues are discussed, and a proposed solution is offered.

  12. Development of natural radiation model for evaluation of background radiation in radiation portal monitor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Bum; Lee, Jin Hyung; Moon, Myung Kook [Radioisotope Research and Development Division, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-11-15

    In ports and airports, radiation portal monitors (RPM) are deployed to detect illicit radioactive materials. Detected gamma rays in a RPM include background radiation and radiation from a freight. As a vehicle moves through the RPM, the vehicle causes the fluctuations in the natural background radiation signal, which ranges of up to 30%. The fluctuation increases the uncertainty of detection signal and can be a cause of RPM false alarm. Therefore, it is important to evaluate background radiation as well as radiation from a container. In this paper, a natural background radiation model was developed to evaluate RPM. To develop natural background radiation model, a Monte Carlo simulation was performed and compared with experimental measurements from a RPM for {sup 40}K, {sup 232}Th series, and {sup 235}U series, which are major sources of natural background radiation. For a natural radiation source, we considered a cylindrical soil volume with 300 m radius and 1 m depth, which was estimated as the maximum range affecting the RPM by MCNP6 simulation. The volume source model was converted to surface source by using MCNP SSW card for computational efficiency. The computational efficiency of the surface source model was improved to approximately 200 times better than that of the volume source model. The surface source model is composed of a hemisphere with 20 m radius in which the RPM and container are modelled. The natural radiation spectrum from the simulation was best fitted to the experimental measurement when portions of {sup 40}K, {sup 232}Th series, and {sup 235}U series were 0.75, 0.0636, and 0.0552 Bq·g{sup -1}, respectively. For gross counting results, the difference between simulation and experiment was around 5%. The background radiation model was used to evaluate background suppression from a 40 ft container with 7.2 m·s{sup -1} speed. In further study, background models and freight models for RPM in real container ports will be developed and applied to

  13. On the usefulness of portal monitor unit subtraction in radiation therapy

    International Nuclear Information System (INIS)

    Kuperman, Vadim Y; Lubich, Leslie M

    2003-01-01

    In order to avoid additional dose to patients caused by portal imaging with megavoltage x-rays, portal monitor units (MUs) are frequently subtracted from the actual treatment MUs. This study examines the usefulness of portal MU subtraction in radiation therapy. For 11 prostate cancer patients treated with 23 MV photons, dose to prostate due to portal filming with 6 MV photons was determined. In all 11 patients subtraction of portal MU values from the actual treatment MUs resulted in a small underdosing of the prostate with an average treatment error of -0.5%. Portal filming without MU subtraction would cause small overdosing of the prostate with an average treatment error of 1.2%. The results of this study indicate that the benefits of portal MU subtraction are in doubt if (a) the energy of treatment x-rays is much higher than that of the portal x-rays and/or (b) when radiotherapy is performed with physical wedges. Based on the obtained results, we argue against unconditional use of the portal MU subtraction method to eliminate the dose from portal imaging

  14. Computer Modeling of Radiation Portal Monitors for Homeland Security Applications

    International Nuclear Information System (INIS)

    Pagh, Richard T.; Kouzes, Richard T.; McConn, Ronald J.; Robinson, Sean M.; Schweppe, John E.; Siciliano, Edward R.

    2005-01-01

    Radiation Portal Monitors (RPMs) are currently being used at our nation's borders to detect potential nuclear threats. At the Pacific Northwest National Laboratory (PNNL), realistic computer models of RPMs are being developed to simulate the screening of vehicles and cargo. Detailed models of the detection equipment, vehicles, cargo containers, cargos, and radioactive sources are being used to determine the optimal configuration of detectors. These models can also be used to support work to optimize alarming algorithms so that they maximize sensitivity for items of interest while minimizing nuisance alarms triggered by legitimate radioactive material in the commerce stream. Proposed next-generation equipment is also being modeled to quantify performance and capability improvements to detect potential nuclear threats. A discussion of the methodology used to perform computer modeling for RPMs will be provided. In addition, the efforts to validate models used to perform these scenario analyses will be described. Finally, areas where improved modeling capability is needed will be discussed as a guide to future development efforts

  15. Experiences with radiation portal detectors for international rail transport

    Science.gov (United States)

    Stromswold, D. C.; McCormick, K.; Todd, L.; Ashbaker, E. D.; Evans, J. C.

    2006-08-01

    Radiation detectors monitored trains at two international borders to evaluate the performance of NaI(Tl) and plastic (polyvinyltoluene: PVT) gamma-ray detectors to characterize rail cargo. The detectors included a prototype NaI(Tl) radiation-portal-monitor panel having four large detectors (10-cm × 10-cm × 41-cm) and a PVT panel with a 41 cm × 173 cm × 3.8-cm detector. Spectral data from the NaI(Tl) and PVT detectors were recorded. Of particular emphasis was the identification of naturally occurring radioactive material (NORM) and the resultant frequency of nuisance alarms. For rail monitoring, the difficulty in stopping trains to perform secondary inspection on alarming cars creates a need for reliable identification of NORM during initial screening. Approximately 30 trains were monitored, and the commodities in individual railcars were ascertained from manifest information. At one test site, the trains carried inter-modal containers that had been unloaded from ships, and at the other site, the trains contained bulk cargo in tanker cars and hopper cars or individual items in boxcars or flatbeds. NORM encountered included potash, liquefied petroleum gas, fireworks, televisions, and clay-based products (e.g., pottery). Analysis of the spectral data included the use of the template-fitting portion of the program GADRAS developed at Sandia National Laboratories. For most of the NORM, the NaI(Tl) data produced a correct identification of the radionuclides present in the railcars. The same analysis was also used for PVT data in which the spectral information (no peaks but only gradual spectral changes including Compton edges) was limited. However, the PVT analysis provided correct identification of 40K and 226Ra in many cases.

  16. Experiences with radiation portal detectors for international rail transport

    International Nuclear Information System (INIS)

    Stromswold, David C.; McCormick, Kathleen R.; Todd, Lindsay C.; Ashbaker, Eric D.; Evans, J.C.

    2006-01-01

    Radiation detectors monitored trains at two international borders to evaluate the performance of NaI(Tl) and plastic (polyvinyltoluene: PVT) gamma-ray detectors to characterize rail cargo. The detectors included a prototype NaI(Tl) radiation-portal-monitor panel having four large detectors (10-cm x 10-cm x 41-cm) and a PVT panel with a 41 cm x 173 cm x 3.8-cm detector. Spectral data from the NaI(Tl) and PVT detectors were recorded. Of particular emphasis was the identification of naturally occurring radioactive material (NORM) and the resultant frequency of nuisance alarms. For rail monitoring, the difficulty in stopping trains to perform secondary inspection on alarming cars creates a need for reliable identification of NORM during initial screening. Approximately 30 trains were monitored, and the commodities in individual railcars were ascertained from manifest information. At one test site the trains carried inter-modal containers that had been unloaded from ships, and at the other site the trains contained bulk cargo or individual items in boxcars or flatbeds. NORM encountered included potash, liquefied petroleum gas, fireworks, televisions, and clay-based products (e.g., pottery). Analysis of the spectral data included the use of the template-fitting program GADRAS/FitToDB from Sandia National Laboratories. For much of the NORM the NaI(Tl) data produced a correct identification of the radionuclides present in the railcars. The same analysis was also used for PVT data in which the spectral information (no peaks but only gradual spectral changes including Compton edges) was limited. However, the PVT analysis provided correct identification of 40K and 226Ra in many cases

  17. Radiation therapists' perceptions of the minimum level of experience required to perform portal image analysis

    International Nuclear Information System (INIS)

    Rybovic, Michala; Halkett, Georgia K.; Banati, Richard B.; Cox, Jennifer

    2008-01-01

    Background and purpose: Our aim was to explore radiation therapists' views on the level of experience necessary to undertake portal image analysis and clinical decision making. Materials and methods: A questionnaire was developed to determine the availability of portal imaging equipment in Australia and New Zealand. We analysed radiation therapists' responses to a specific question regarding their opinion on the minimum level of experience required for health professionals to analyse portal images. We used grounded theory and a constant comparative method of data analysis to derive the main themes. Results: Forty-six radiation oncology facilities were represented in our survey, with 40 questionnaires being returned (87%). Thirty-seven radiation therapists answered our free-text question. Radiation therapists indicated three main themes which they felt were important in determining the minimum level of experience: 'gaining on-the-job experience', 'receiving training' and 'working as a team'. Conclusions: Radiation therapists indicated that competence in portal image review occurs via various learning mechanisms. Further research is warranted to determine perspectives of other health professionals, such as radiation oncologists, on portal image review becoming part of radiation therapists' extended role. Suitable training programs and steps for implementation should be developed to facilitate this endeavour

  18. Evaluation of usefulness of portal image using Electronic Portal Imaging Device (EPID) in the patients who received pelvic radiation therapy

    International Nuclear Information System (INIS)

    Kim, Woo Chul; Kim, Heon Jong; Park, Seong Young; Cho, Young Kap; Loh, John J. K.; Park, Won; Suh, Chang Ok; Kim, Gwi Eon

    1998-01-01

    To evaluate the usefulness of electronic portal imaging device through objective compare of the images acquired using an EPID and a conventional port film. From Apr. to Oct. 1997, a total of 150 sets of images from 20 patients who received radiation therapy in the pelvis area were evaluated in the Inha University Hospital and Severance Hospital. A dual image recording technique was devised to obtain both electronic portal images and port film images simultaneously with one treatment course. We did not perform double exposure. Five to ten images were acquired from each patient. All images were acquired from posteroanterior (PA) view except images from two patients. A dose rate of 100-300 MU/min and a 10-MV X-ray beam were used and 2-10 MUs were required to produce a verification image during treatment. Kodak diagnostic film with metal/film imaging cassette which was located on the top of the EPID detector was used for the port film. The source to detector distance was 140 cm. Eight anatomical landmarks (pelvic brim, sacrum, acetabulum, iliopectineal line, symphysis, ischium, obturator foramen, sacroiliac joint) were assessed. Four radiation oncologist joined to evaluate each image. The individual landmarks in the port film or in the EPID were rated-very clear (1), clear (2), visible (3), notclear (4), not visible (5). Using an video camera based EPID system, there was no difference of image quality between no enhanced EPID images and port film images. However, when we provided some change with window level for the portal image, the visibility of the sacrum and obturator foramen was improved in the portal images than in the port film images. All anatomical landmarks were more visible in the portal images than in the port film when we applied the CLAHE mode enhancement. The images acquired using an matrix ion chamber type EPID were also improved image quality after window level adjustment. The quality of image acquired using an electronic portal imaging device was

  19. Study of radiation portal monitor and its application to metal recycling industry

    International Nuclear Information System (INIS)

    Pujol, L.; Lara-Calleja, S.; Suarez-Navarro, M. J.; Gonzalez-Gonzalez, J. A.

    2009-01-01

    The industry of the iron and the steel in one of the most important sectors in Spain for its economic development. the recycling of metallic materials as well as the import of metallic scrap is very significant. Several reports on accidental dispersion or smelting of radioactive sources in metal recycling industries confirm the possibility that radioactive material might be mixed with scrap. In consequence, this type of accident shows the necessity of a rigorous and specific radiation control of the sector. The control of these materials with radioactive content can be carried out with radiation portal monitors installed at the entrance of these industries. The detection of radioactive materials presents special features as the continuous background acquisition or the minimisation of the relatively large number of innocent/nuisance detections. In the present work, we study a radiation portal monitor, the FHT-1388-T Thermo-Eberline. This is one of the usual radiation portal systems installed at the entrance of the metal recycling industry. Se study the characteristics and parameters of this portal monitor to optimise its use. furthermore, we propose some rapid tests for radiation portal systems in metal recycling industry. (Author) 16 refs

  20. Development of NORM determination Algorithm for Radiation Portal Monitors

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Hwan; Kim, Ye Won; Yoo, Hyun Jun; Kim, Chan Kyu; Lee, Sang Heon; Cho, Gyu Seong [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    In this paper, probability of distinguishing nuclide analysis is proposed by measuring compton energy spectrum of gamma ray with large-area PVT scintillator to solve fundamental problem. US coast guard (USCG) suggested the methods for which terrorism could be prevented to international maritime organization (IMO) and the bill in which container safety was assured was suggested by U.S customs officials. However, radiation portal monitors (RPMs) running at the airport and the harbor cannot distinguish special cargo material (SNM) from naturally occurring radioactive materials (NOMR) containing a small dose of radioisotope from nature. Consequently, cargo sorted out by RPM using polyvinyl-toluene (PVT) scintillator contains approximately 99% of NORM (such as cat litter, potash, tableware and etc.) Many research institutes are under way to reduce such a nuisance alarm. Tom Burr conducted pattern recognition methods with extracted 184 features (46 features from each of four panels) from 235 profiles out of 406 profiles representing gamma alarm. But this method is more like statistical analysis using the data of low and high gamma than practical nuclide analysis. So it has limitation to reduce nuisance alarm. Regarding to the experimental result for difference distances between the source and the scintillator using large-area PVT based plastic scintillator, the linearity was not secured when the distance is from 0cm to 20cm. It is expected that, for these cases, the scintillation areas in which photon is emitted were small. The distance between PMTs and these areas was too far to detect every emitted photon because the photons were attenuated by plastic scintillator. Because of this reason, energy spectra were shifted to relatively lower channel. While, no more spectrum shifting occurred for 50cm and 100cm. It is considered that the increase of the gamma source solid angle makes scintillation area larger and no more spectrum shifting occur. With this experiment, it was

  1. Development of NORM determination Algorithm for Radiation Portal Monitors

    International Nuclear Information System (INIS)

    Kim, Jin Hwan; Kim, Ye Won; Yoo, Hyun Jun; Kim, Chan Kyu; Lee, Sang Heon; Cho, Gyu Seong

    2016-01-01

    In this paper, probability of distinguishing nuclide analysis is proposed by measuring compton energy spectrum of gamma ray with large-area PVT scintillator to solve fundamental problem. US coast guard (USCG) suggested the methods for which terrorism could be prevented to international maritime organization (IMO) and the bill in which container safety was assured was suggested by U.S customs officials. However, radiation portal monitors (RPMs) running at the airport and the harbor cannot distinguish special cargo material (SNM) from naturally occurring radioactive materials (NOMR) containing a small dose of radioisotope from nature. Consequently, cargo sorted out by RPM using polyvinyl-toluene (PVT) scintillator contains approximately 99% of NORM (such as cat litter, potash, tableware and etc.) Many research institutes are under way to reduce such a nuisance alarm. Tom Burr conducted pattern recognition methods with extracted 184 features (46 features from each of four panels) from 235 profiles out of 406 profiles representing gamma alarm. But this method is more like statistical analysis using the data of low and high gamma than practical nuclide analysis. So it has limitation to reduce nuisance alarm. Regarding to the experimental result for difference distances between the source and the scintillator using large-area PVT based plastic scintillator, the linearity was not secured when the distance is from 0cm to 20cm. It is expected that, for these cases, the scintillation areas in which photon is emitted were small. The distance between PMTs and these areas was too far to detect every emitted photon because the photons were attenuated by plastic scintillator. Because of this reason, energy spectra were shifted to relatively lower channel. While, no more spectrum shifting occurred for 50cm and 100cm. It is considered that the increase of the gamma source solid angle makes scintillation area larger and no more spectrum shifting occur. With this experiment, it was

  2. Radionuclide identification algorithm for organic scintillator-based radiation portal monitor

    Energy Technology Data Exchange (ETDEWEB)

    Paff, Marc Gerrit, E-mail: mpaff@umich.edu; Di Fulvio, Angela; Clarke, Shaun D.; Pozzi, Sara A.

    2017-03-21

    We have developed an algorithm for on-the-fly radionuclide identification for radiation portal monitors using organic scintillation detectors. The algorithm was demonstrated on experimental data acquired with our pedestrian portal monitor on moving special nuclear material and industrial sources at a purpose-built radiation portal monitor testing facility. The experimental data also included common medical isotopes. The algorithm takes the power spectral density of the cumulative distribution function of the measured pulse height distributions and matches these to reference spectra using a spectral angle mapper. F-score analysis showed that the new algorithm exhibited significant performance improvements over previously implemented radionuclide identification algorithms for organic scintillators. Reliable on-the-fly radionuclide identification would help portal monitor operators more effectively screen out the hundreds of thousands of nuisance alarms they encounter annually due to recent nuclear-medicine patients and cargo containing naturally occurring radioactive material. Portal monitor operators could instead focus on the rare but potentially high impact incidents of nuclear and radiological material smuggling detection for which portal monitors are intended.

  3. Radionuclide identification algorithm for organic scintillator-based radiation portal monitor

    Science.gov (United States)

    Paff, Marc Gerrit; Di Fulvio, Angela; Clarke, Shaun D.; Pozzi, Sara A.

    2017-03-01

    We have developed an algorithm for on-the-fly radionuclide identification for radiation portal monitors using organic scintillation detectors. The algorithm was demonstrated on experimental data acquired with our pedestrian portal monitor on moving special nuclear material and industrial sources at a purpose-built radiation portal monitor testing facility. The experimental data also included common medical isotopes. The algorithm takes the power spectral density of the cumulative distribution function of the measured pulse height distributions and matches these to reference spectra using a spectral angle mapper. F-score analysis showed that the new algorithm exhibited significant performance improvements over previously implemented radionuclide identification algorithms for organic scintillators. Reliable on-the-fly radionuclide identification would help portal monitor operators more effectively screen out the hundreds of thousands of nuisance alarms they encounter annually due to recent nuclear-medicine patients and cargo containing naturally occurring radioactive material. Portal monitor operators could instead focus on the rare but potentially high impact incidents of nuclear and radiological material smuggling detection for which portal monitors are intended.

  4. Rain-Induced Increase in Background Radiation Detected by Radiation Portal Monitors

    Energy Technology Data Exchange (ETDEWEB)

    Hausladen, Paul [ORNL; Blessinger, Christopher S [ORNL; Guzzardo, Tyler [ORNL; Livesay, Jake [ORNL

    2012-07-01

    A complete understanding of both the steady state and transient background measured by Radiation Portal Monitors (RPMs) is essential to predictable system performance, as well as maximization of detection sensitivity. To facilitate this understanding, a test bed for the study of natural background in RPMs has been established at the Oak Ridge National Laboratory. This work was performed in support of the Second Line of Defense Program's mission to detect the illicit movement of nuclear material. In the present work, transient increases in gamma ray counting rates in RPMs due to rain are investigated. The increase in background activity associated with rain, which has been well documented in the field of environmental radioactivity, originates from the atmospheric deposition of two radioactive daughters of radon-222, namely lead-214 and bismuth-214 (henceforth {sup 222}Rn, {sup 214}Pb and {sup 214}Bi). In this study, rainfall rates recorded by a co-located weather station are compared with RPM count rates and High Purity Germanium spectra. The data verifies these radionuclides are responsible for the dominant transient natural background fluctuations in RPMs. Effects on system performance and potential mitigation strategies are discussed.

  5. Radiation therapists' perceptions of the minimum level of experience required to perform portal image analysis

    Energy Technology Data Exchange (ETDEWEB)

    Rybovic, Michala [Discipline of Medical Radiation Sciences, Faculty of Health Sciences, University of Sydney, PO Box 170, Lidcombe, NSW 1825 (Australia)], E-mail: mryb6983@mail.usyd.edu.au; Halkett, Georgia K. [Western Australia Centre for Cancer and Palliative Care, Curtin University of Technology, Health Research Campus, GPO Box U1987, Perth, WA 6845 (Australia)], E-mail: g.halkett@curtin.edu.au; Banati, Richard B. [Faculty of Health Sciences, Brain and Mind Research Institute - Ramaciotti Centre for Brain Imaging, University of Sydney, PO Box 170, Lidcombe, NSW 1825 (Australia)], E-mail: r.banati@usyd.edu.au; Cox, Jennifer [Discipline of Medical Radiation Sciences, Faculty of Health Sciences, University of Sydney, PO Box 170, Lidcombe, NSW 1825 (Australia)], E-mail: jenny.cox@usyd.edu.au

    2008-11-15

    Background and purpose: Our aim was to explore radiation therapists' views on the level of experience necessary to undertake portal image analysis and clinical decision making. Materials and methods: A questionnaire was developed to determine the availability of portal imaging equipment in Australia and New Zealand. We analysed radiation therapists' responses to a specific question regarding their opinion on the minimum level of experience required for health professionals to analyse portal images. We used grounded theory and a constant comparative method of data analysis to derive the main themes. Results: Forty-six radiation oncology facilities were represented in our survey, with 40 questionnaires being returned (87%). Thirty-seven radiation therapists answered our free-text question. Radiation therapists indicated three main themes which they felt were important in determining the minimum level of experience: 'gaining on-the-job experience', 'receiving training' and 'working as a team'. Conclusions: Radiation therapists indicated that competence in portal image review occurs via various learning mechanisms. Further research is warranted to determine perspectives of other health professionals, such as radiation oncologists, on portal image review becoming part of radiation therapists' extended role. Suitable training programs and steps for implementation should be developed to facilitate this endeavour.

  6. Extrahepatic portal vein occlusion without recurrence after pancreaticoduodenectomy and intraoperative radiation therapy

    International Nuclear Information System (INIS)

    Mitsunaga, Shuichi; Kinoshita, Taira; Kawashima, Mitsuhiko; Konishi, Masaru; Nakagohri, Toshio; Takahashi, Shinichiro; Gotohda, Naoto

    2006-01-01

    Purpose: Although there are no definitive studies that characterize the survival benefit of intraoperative radiation therapy (IORT), the therapy does not seem to produce significant complication. In our institution, pancreaticoduodenectomy (PD) and IORT are often complicated by the development of extrahepatic portal vein occlusion (EHPO). The aim of this study was to characterize the phenomenon of EHPO after PD and IORT. Methods and Materials: Between September 1992 and December 2001, 107 patients received macroscopic curative PD for periampullary disease in our institution. IORT (radiation dose: 20 Gy) was performed in 53 of these patients. Criteria for diagnosis of EHPO were as follows: (1) computerized tomography findings of occlusive extrahepatic portal vein (2) symptoms of portal hypertension, and (3) confirmation to exclude tumor recurrence from origin of EHPO, because this study examined whether EHPO was a complication of PD and IORT. Results: EHPO was diagnosed in 12 patients. Among patient and operative variables, IORT was the only statistically significant factor associated with a diagnosis of EHPO (p = 0.0052). The median developed time to EHPO and overall survival after surgery in EHPO patients were 358 days and 2,562 days, respectively. Eight patients (67%) with EHPO died during the follow-up period. At 5 years after therapy, EHPO was diagnosed in 67% of survivors who had received IORT. Conclusions: Patients undergoing IORT and PD have a relatively high incidence of EHPO, and patients who develop postoperative EHPO have poor prognoses

  7. Validation of intensity modulated radiation therapy patient plans with portal images

    International Nuclear Information System (INIS)

    Delpon, G.; Warren, S.; Mahe, D.; Gaudaire, S.; Lisbona, A.

    2007-01-01

    The goal of this study was to show the feasibility of step and shoot intensity-modulated radiation therapy pre-treatment quality control for patients using the electronic portal imaging device (iViewGT) fitted on a Sli+ linac (Elekta Oncology Systems, Crawley, UK) instead of radiographic films. Since the beginning of intensity-modulated radiation therapy treatments, the dosimetric quality control necessary before treating each new patient has been a time-consuming and therefore costly obligation. In order to fully develop this technique, it seems absolutely essential to reduce the cost of these controls, especially the linac time. Up to now, verification of the relative dosimetry field by field has been achieved by acquiring radiographic films in the isocenter plane and comparing them to the results of the XiO planning system (Computerized Medical Systems, Missouri, USA) using RIT113 v4.1 software (Radiological Imaging Technology, Colorado, USA). A qualitative and quantitative evaluation was realised for every field of every patient. A quick and simple procedure was put into place to be able to make the same verifications using portal images. This new technique is not a modification of the overall methodology of analysis. The results achieved by comparing the measurement with the electronic portal imaging device and the calculation with the treatment planning system were in line with those achieved with the films for all indicators we studied (isodoses, horizontal and vertical dose profiles and gamma index). (authors)

  8. Harmonization of the Spanish radiation protection education and training system: educational specialized portal

    International Nuclear Information System (INIS)

    Marco Arboli, Marisa; Rodriguez Suarez, M.; Villarroel Gonzalez Elipe, R.; Rodriguez Marti, M.

    2008-01-01

    Full text: This paper shows the educational project developed by the Spanish Regulatory Body (CSN) and CIEMAT. The Radiation Protection Training and Education Portal is included in the framework of the regulated training system in Spain. The project is available on the CSN web site 'www.csn.es'. The main objective of this specialized portal is to provide the necessary mechanisms for standardization of the radiation protection knowledge and to provide training tools. One of the priorities of this project is to spread in Latino America the efforts of a big group of professionals made in the past years on education and training. The initiative also aims to collaborate and share resources. The web site is used for delivery of education content. The RP E and T Portal provides training material for course organizers, trainers and professionals involved. The project includes training tools for sixteen courses based in the standard syllabus content in the Spanish regulations. The courses have been prepared in a modular approach with specific modules focused in medical and industrial applications and prepared taking into account the different target groups and common levels. Each one of the modules includes learning objectives, syllabus, training schedule, theoretical lessons and practical sessions guidance, visual aids for trainers and test and questions to be used as self-evaluation. The training packages cover the initial training programmes needed by supervisors and operators of radioactive facilities in different areas of expertise including diagnostic radiology. The tasks in each of the modules have been designed to develop specific competence. More than 40 recognized experts have participated in this useful open project and their contribution to the training material offer important results and based on their experience having special attention on the quality of the material. (author)

  9. Use of portal radiography to increase accuracy of dose delivery in radiation therapy

    International Nuclear Information System (INIS)

    McEntee, M.C.; Thrall, D.E.

    1995-01-01

    Port films were acquired for all radiation therapy patients (n = 132) treated over a thirteen month period to 1) assist in initial treatment field set-up on Day 1, 2) for quality assurance with a second port film taken on Day 7 of radiation therapy, and 3) as a means to document the radiation treatment field as a part of the patients permanent medical record. Port films were used for both patients treated with a definitive course of radiation (n = 97 patients), and those treated palliatively (n = 35 patients). The portal radiographs were valuable in terms of the initial set-up, and to correct for any positioning or other errors at the time of the one week recheck. Changes were made, based on the initial port film on Day 1, in 53 % and 57% of treatment fields for palliative and definitive radiation patients, respectively. The changes made in both definitively and palliatively irradiated patients were usually in field position, an increase in field size to include all of the tumor, or a decrease in field size to spare normal tissue. Fewer changes were necessary based on the Day 7 recheck port films, but these day-7 rechecks are recommended for quality control. Based on the high frequency of changes introduced because of the initial port film findings, it is recommended. that port films be incorporated on a routine basis in veterinary radiation therapy

  10. Development of a daily dosimetric control for radiation therapy using an electronic portal imaging device (EPID)

    International Nuclear Information System (INIS)

    Saboori, Mohammadsaeed

    2015-01-01

    Electronic Portal Imaging Devices (EPIDs) can be used to perform dose measurements during radiation therapy treatments if dedicated calibration and correction procedures are applied. The purpose of this study was to provide a new calibration and correction model for an amorphous silicon (a-Si) EPID for use in transit dose verification of step-and-shoot intensity modulated radiation therapy (IMRT). A model was created in a commercial treatment planning system to calculate the nominal two-dimensional (2D) dose map of each radiation field at the EPID level. The EPID system was calibrated and correction factors were determined using a reference set-up, which consisted a patient phantom and an EPID phantom. The advantage of this method is that for the calibration, the actual beam spectrum is used to mimic a patient measurement. As proof-of-principle, the method was tested for the verification of two 7-field IMRT treatment plans with tumor sites in the head-and-neck and pelvic region. Predicted and measured EPID responses were successfully compared to the nominal data from treatment planning using dose difference maps and gamma analyses. Based on our result it can be concluded that this new method of 2D EPID dosimetry is a potential tool for simple patient treatment fraction dose verification.

  11. The characteristics of Fugi IP Cassette Type PII and application for radiation oncology quality assurance tests and portal imaging

    International Nuclear Information System (INIS)

    Soh, H.S.; Ung, N.M.; Ng, K.H.

    2008-01-01

    Full text: The advancement of digital imaging has prompted more medical institutions to go filmless. The computed radiography (CR) system is becoming an important tool not only in diagnostic imaging, but also in radiation oncology. A new CR system that was specially designed for the use in radiation oncology. Fuji IP cassette type PII has been introduced to the market in the middle of year 2006. This project aimed to study some basic physical characteristics of this new type of cassette and explore its application for performing quality assurance (QA) tests and portal imaging in radiotherapy. All the images were read by FCR 5000 Plus reader. The image was found to reach its saturation value of 1023 (due to the image was stored in 10 bits data) by depending on the sensitivity value being adjusted. The uniformity test gave the result of 0.12%. The cassette was used to perform the QA tests which were previously performed using film. All the results met the specification as stated in AAPM Task Group 40. The comparison for the portal images of Portal Vision contrast-detail phantom showed that the spatial resolution of the images obtained by CR system (Fujifilm Co.. Ltd.. Tokyo. Japan) were better than the EPID (Varian Medical Systems. Inc.. Palo Alto. USA) and film system (Eastman Kodak Co.. New York. USA). The IP cassette type PII was found to be suitable as an alternative QA test tool and portal imaging in radiotherapy.

  12. Optimising the neutron environment of Radiation Portal Monitors: A computational study

    Energy Technology Data Exchange (ETDEWEB)

    Gilbert, Mark R., E-mail: mark.gilbert@ccfe.ac.uk [United Kingdom Atomic Energy Authority, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Ghani, Zamir [United Kingdom Atomic Energy Authority, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); McMillan, John E. [Department of Physics and Astronomy, University of Sheffield, Hicks building, Hounsfield Road, Sheffield S3 7RH (United Kingdom); Packer, Lee W. [United Kingdom Atomic Energy Authority, Culham Science Centre, Abingdon OX14 3DB (United Kingdom)

    2015-09-21

    Efficient and reliable detection of radiological or nuclear threats is a crucial part of national and international efforts to prevent terrorist activities. Radiation Portal Monitors (RPMs), which are deployed worldwide, are intended to interdict smuggled fissile material by detecting emissions of neutrons and gamma rays. However, considering the range and variety of threat sources, vehicular and shielding scenarios, and that only a small signature is present, it is important that the design of the RPMs allows these signatures to be accurately differentiated from the environmental background. Using Monte-Carlo neutron-transport simulations of a model {sup 3}He detector system we have conducted a parameter study to identify the optimum combination of detector shielding, moderation, and collimation that maximises the sensitivity of neutron-sensitive RPMs. These structures, which could be simply and cost-effectively added to existing RPMs, can improve the detector response by more than a factor of two relative to an unmodified, bare design. Furthermore, optimisation of the air gap surrounding the helium tubes also improves detector efficiency.

  13. Investigation of energy windowing algorithms for effective cargo screening with radiation portal monitors

    International Nuclear Information System (INIS)

    Hevener, Ryne; Yim, Man-Sung; Baird, Ken

    2013-01-01

    Radiation portal monitors (RPMs) are distributed across the globe in an effort to decrease the illicit trafficking of nuclear materials. Many current generation RPMs utilizes large polyvinyltoluene (PVT) plastic scintillators. These detectors are low cost and reliable but have very poor energy resolution. The lack of spectroscopic detail available from PVT spectra has restricted these systems primarily to performing simple gross counting measurements in the past. A common approach to extend the capability of PVT detectors beyond simple “gross-gamma” use is to apply a technique known as energy windowing (EW) to perform rough nuclide identification with limited spectral information. An approach to creating EW algorithms was developed in this work utilizing a specific set of calibration sources and modified EW equations; this algorithm provided a degree of increased identification capability. A simulated real-time emulation of the algorithm utilizing actual port-of-entry RPM data supplied by ORNL provided an extensive proving ground for the algorithm. This algorithm is able to identify four potential threat nuclides and the major NORM source with a high degree of accuracy. High-energy masking, a major detriment of EW algorithms, is reduced by the algorithm's design. - Highlights: • Gross counting algorithms do not produce detailed screenings. • Energy windowing algorithms enhance nuclide identification capability. • Proper use of EW algorithm can identify multiple threat nuclides. • Utilizing specific set of calibration sources is important for nuclide identification

  14. Estimation of four-dimensional dose distribution using electronic portal imaging device in radiation therapy

    International Nuclear Information System (INIS)

    Mizoguchi, Asumi; Arimura, Hidetaka; Shioyama, Yoshiyuki

    2013-01-01

    We are developing a method to evaluate four-dimensional radiation dose distribution in a patient body based upon the animated image of EPID (electronic portal imaging device) which is an image of beam-direction at the irradiation. In the first place, we have obtained the image of the dose which is emitted from patient body at therapy planning using therapy planning CT image and dose evaluation algorism. In the second place, we have estimated the emission dose image at the irradiation using EPID animated image which is obtained at the irradiation. In the third place, we have got an affine transformation matrix including respiratory movement in the body by performing linear registration on the emission dose image at therapy planning to get the one at the irradiation. In the fourth place, we have applied the affine transformation matrix on the therapy planning CT image and estimated the CT image 'at irradiation'. Finally we have evaluated four-dimensional dose distribution by calculating dose distribution in the CT image 'at irradiation' which has been estimated for each frame of the EPID animated-image. This scheme may be useful for evaluating therapy results and risk management. (author)

  15. Evaluation of image quality for various electronic portal imaging devices in radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Son, Soon Yong; Choi, Kwan Woo [Dept. of Radiology, Asan Medical Center, Seoul (Korea, Republic of); Kim, Jung Min [Dept. of College of Health Science, Radiologic Science, Korea University, Seoul (Korea, Republic of); and others

    2015-12-15

    In megavoltage (MV) radiotherapy, delivering the dose to the target volume is important while protecting the surrounding normal tissue. The purpose of this study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) using an edge block in megavoltage X-ray imaging (MVI). We used an edge block, which consists of tungsten with dimensions of 19 (thickness) × 10 (length) × 1 (width) cm3 and measured the pre-sampling MTF at 6 MV energy. Various radiation therapy (RT) devices such as TrueBeamTM (Varian), BEAMVIEWPLUS (Siemens), iViewGT (Elekta) and Clinac®iX (Varian) were used. As for MTF results, TrueBeamTM(Varian) flattening filter free(FFF) showed the highest values of 0.46 mm-1and1.40mm-1for MTF 0.5 and 0.1. In NPS, iViewGT (Elekta) showed the lowest noise distribution. In DQE, iViewGT (Elekta) showed the best efficiency at a peak DQE and 1 mm-1DQE of 0.0026 and 0.00014, respectively. This study could be used not only for traditional QA imaging but also for quantitative MTF, NPS, and DQE measurement for development of an electronic portal imaging device (EPID)

  16. Dosimetric verification of radiation therapy including intensity modulated treatments, using an amorphous-silicon electronic portal imaging device

    Science.gov (United States)

    Chytyk-Praznik, Krista Joy

    Radiation therapy is continuously increasing in complexity due to technological innovation in delivery techniques, necessitating thorough dosimetric verification. Comparing accurately predicted portal dose images to measured images obtained during patient treatment can determine if a particular treatment was delivered correctly. The goal of this thesis was to create a method to predict portal dose images that was versatile and accurate enough to use in a clinical setting. All measured images in this work were obtained with an amorphous silicon electronic portal imaging device (a-Si EPID), but the technique is applicable to any planar imager. A detailed, physics-motivated fluence model was developed to characterize fluence exiting the linear accelerator head. The model was further refined using results from Monte Carlo simulations and schematics of the linear accelerator. The fluence incident on the EPID was converted to a portal dose image through a superposition of Monte Carlo-generated, monoenergetic dose kernels specific to the a-Si EPID. Predictions of clinical IMRT fields with no patient present agreed with measured portal dose images within 3% and 3 mm. The dose kernels were applied ignoring the geometrically divergent nature of incident fluence on the EPID. A computational investigation into this parallel dose kernel assumption determined its validity under clinically relevant situations. Introducing a patient or phantom into the beam required the portal image prediction algorithm to account for patient scatter and attenuation. Primary fluence was calculated by attenuating raylines cast through the patient CT dataset, while scatter fluence was determined through the superposition of pre-calculated scatter fluence kernels. Total dose in the EPID was calculated by convolving the total predicted incident fluence with the EPID-specific dose kernels. The algorithm was tested on water slabs with square fields, agreeing with measurement within 3% and 3 mm. The

  17. Incidence of primary hypothyroidism in patients exposed to therapeutic external beam radiation, where radiation portals include a part or whole of the thyroid gland

    Directory of Open Access Journals (Sweden)

    B A Laway

    2012-01-01

    Full Text Available Introduction: Hypothyroidism is a known consequence of external-beam radiotherapy to the neck encompassing a part or whole of the thyroid gland. In this non-randomized prospective study, we have tried to evaluate the response of the thyroid gland to radiation by assessing thyroid function before irradiation and at regular intervals after irradiation. Aims and Objectives: The aim of this study were to assess in the cancer patients, who were exposed to the therapeutic external beam radiation, where radiation portals include a part or whole of the thyroid gland: the incidence of primary hypothyroidism, the time required to become hypothyroid, any relation between the total dose for the development of hypothyroidism, and whether there are any patient or treatment-related factors that are predictive for the development of hypothyroidism, including the use of concurrent chemotherapy. Materials and Methods: This non-randomized, prospective study was conducted for a period of 2 years in which thyroid function was assessed in 59 patients (cases of head and neck cancer, breast cancer, lymphoma patients and other malignancies, who had received radiotherapy to the neck region. 59 euthyroid healthy patients (controls were also taken, who had not received the neck irradiation. These patients/controls were assessed periodically for 2 years. Results: The incidence of hypothyroidism after external beam radiation therapy (EBRT to neck where radiation portals include part or whole of the thyroid gland was 16.94%, seven cases had subclinical hypothyroidism (11.86% and three cases had clinical hypothyroidism (5.08%. Mean time for development of hypothyroidism was 4.5 months. There was no effect of age, gender, primary tumor site, radiation dose and chemotherapy, whether neoadjuvant or concurrent with the development of hypothyroidism. Conclusion: In summary, we found that thyroid dysfunction is a prevalent, yet easily treatable source of morbidity in patients

  18. Selective internal radiation therapy compared with sorafenib for hepatocellular carcinoma with portal vein thrombosis

    Energy Technology Data Exchange (ETDEWEB)

    Edeline, Julien [Centre Eugene Marquis, Medical Oncology Department, Rennes (France); Inserm UMR991, Rennes (France); Crouzet, Laurence; Pracht, Marc; Boucher, Eveline [Centre Eugene Marquis, Medical Oncology Department, Rennes (France); Campillo-Gimenez, Boris [Centre Eugene Marquis, Clinical Research Department, Rennes (France); Rolland, Yan; Rohou, Tanguy [Centre Eugene Marquis, Imaging Department, Rennes (France); Guillygomarc' h, Anne [CHU Pontchaillou, Hepatology Department, Rennes (France); Boudjema, Karim [CHU Pontchaillou, Hepatobiliary Surgery, Rennes (France); Lenoir, Laurence [Centre Eugene Marquis, Nuclear Medicine Department, Rennes (France); Adhoute, Xavier [Hopital Saint-Joseph, Hepato-Gastroenterology Department, Marseille (France); Clement, Bruno [Inserm UMR991, Rennes (France); Blanc, Jean-Frederic [Hopital Saint-Andre, Hepato-Gastroenterology Department, Bordeaux (France); Garin, Etienne [Inserm UMR991, Rennes (France); Centre Eugene Marquis, Nuclear Medicine Department, Rennes (France)

    2016-04-15

    Tumoural portal vein thrombosis (PVT) is a major prognostic factor in hepatocellular carcinoma (HCC). The efficacy of sorafenib, the only treatment approved at an advanced stage, is limited. Based on previous data, selective internal radiation therapy (SIRT), or {sup 90}Y radioembolization, seems an interesting option. We aimed to compare both treatments in this population. We retrospectively compared patients treated in two centres for HCC with tumoural PVT. We compared overall survival (OS) between patients treated with SIRT and patients treated with sorafenib. Analyses were performed before and after 1:1 matching with a propensity score for controlling indication bias, using a Cox proportional hazards model. A total of 151 patients were analysed, 34 patients treated with SIRT and 117 patients treated with sorafenib only. In the whole population, SIRT was associated with a higher median OS as compared with sorafenib: 18.8 vs 6.5 months (log-rank p < 0.001). There was an imbalance of baseline characteristics between patients treated by SIRT and sorafenib, which justified patient matching with use of a propensity score: 24 patients treated with SIRT could be matched with 24 patients treated with sorafenib. OS was estimated with a median of 26.2 vs 8.7 months in patients treated with SIRT vs sorafenib, respectively (log-rank p = 0.054). Before and after patient matching, the adjusted hazard ratio related to treatment by SIRT was estimated at 0.62 [95 % confidence interval (CI) 0.39-0.97] (p = 0.037) and 0.40 (95 % CI 0.19-0.82) (p = 0.013), respectively. SIRT seems more effective than sorafenib in patients presenting with HCC and tumoural PVT. This hypothesis is being tested in prospective randomized trials. (orig.)

  19. Selective internal radiation therapy compared with sorafenib for hepatocellular carcinoma with portal vein thrombosis

    International Nuclear Information System (INIS)

    Edeline, Julien; Crouzet, Laurence; Pracht, Marc; Boucher, Eveline; Campillo-Gimenez, Boris; Rolland, Yan; Rohou, Tanguy; Guillygomarc'h, Anne; Boudjema, Karim; Lenoir, Laurence; Adhoute, Xavier; Clement, Bruno; Blanc, Jean-Frederic; Garin, Etienne

    2016-01-01

    Tumoural portal vein thrombosis (PVT) is a major prognostic factor in hepatocellular carcinoma (HCC). The efficacy of sorafenib, the only treatment approved at an advanced stage, is limited. Based on previous data, selective internal radiation therapy (SIRT), or 90 Y radioembolization, seems an interesting option. We aimed to compare both treatments in this population. We retrospectively compared patients treated in two centres for HCC with tumoural PVT. We compared overall survival (OS) between patients treated with SIRT and patients treated with sorafenib. Analyses were performed before and after 1:1 matching with a propensity score for controlling indication bias, using a Cox proportional hazards model. A total of 151 patients were analysed, 34 patients treated with SIRT and 117 patients treated with sorafenib only. In the whole population, SIRT was associated with a higher median OS as compared with sorafenib: 18.8 vs 6.5 months (log-rank p < 0.001). There was an imbalance of baseline characteristics between patients treated by SIRT and sorafenib, which justified patient matching with use of a propensity score: 24 patients treated with SIRT could be matched with 24 patients treated with sorafenib. OS was estimated with a median of 26.2 vs 8.7 months in patients treated with SIRT vs sorafenib, respectively (log-rank p = 0.054). Before and after patient matching, the adjusted hazard ratio related to treatment by SIRT was estimated at 0.62 [95 % confidence interval (CI) 0.39-0.97] (p = 0.037) and 0.40 (95 % CI 0.19-0.82) (p = 0.013), respectively. SIRT seems more effective than sorafenib in patients presenting with HCC and tumoural PVT. This hypothesis is being tested in prospective randomized trials. (orig.)

  20. Lab-Based Measurement of Remediation Techniques for Radiation Portal Monitors (Initial Report)

    International Nuclear Information System (INIS)

    Livesay, Jake

    2012-01-01

    Radiation Portal Monitors (RPM) deployed by the Second Line of Defense (SLD) are known to be sensitive to the natural environmental radioactive background. There are several techniques used to mitigate the effects of background on the monitors, but since the installation environments can vary significantly from one another the need for a standardized, systematic, study of remediation techniques was proposed and carried out. This study is not meant to serve as the absolute last word on the subject. The data collected are, however, intelligible and useful. Some compromises were made, each of which will be described in detail. The hope of this initial report is to familiarize the SLD science teams with ORNL's effort to model the effect of various remediation techniques on simple, static backgrounds. This study provides a good start toward benchmarking the model, and each additional increment of data will serve to make the model more robust. The scope of this initial study is limited to a few basic cases. Its purpose is to prove the utility of lab-based study of remediation techniques and serve as a standard data set for future use. This importance of this first step of standardization will become obvious when science teams are working in parallel on issues of remediation; having a common starting point will do away with one category of difference, thereby making easier the task of determining the sources of disagreement. Further measurements will augment this data set, allowing for further constraint of the universe of possible situations. As will be discussed in the 'Going Forward' section, more data will be included in the final report of this work. Of particular interest will be the data taken with the official TSA lead collimators, which will provide more direct results for comparison with installation data.

  1. Elimination of quarterly urinalysis of radiation workers based on detection capability of portal monitors for internal contamination

    International Nuclear Information System (INIS)

    Ramanuja, Jayalakshmi

    2012-01-01

    Covidien is a radiopharmaceutical manufacturing company in Missouri, USA. The facility produces radionuclides for diagnostic and therapeutic use. The radionuclides of interest, 123 I, 67 Ga, 99 Mo, 99m Tc, 201 Tl, 111 In, and 131 I are fairly short lived with the exception of 51 Cr. The operating license document for the company mandated quarterly urinalysis (bioassay) of all radiation workers in the facility. This was labor intensive and did not enhance the quality of radiation protection program. Nuclear Regulatory Commission (NRC) required a technical basis to prove that there was no compromise in the radiological safety and accurate dose assessment in the event of internal contamination of radiation workers if quarterly urinalysis was discontinued. Measurements in a phantom, gamma spectroscopy analysis, as well as calculations showed that there was no need to perform quarterly urinalysis and that portal monitors and other radiological controls were sufficient to detect any chronic or acute intake of radioactivity by radiation workers. Technical evaluation showed Portal monitors can detect an Effective Dose Equivalent of 0.1 mSv (10 mrem) in a year. NRC allowed revision of operating license document and operating procedures to discontinue quarterly urinalysis. (author)

  2. Technical and clinical evaluation of an improved-contrast screen-film combination for radiation therapy portal localization imaging

    International Nuclear Information System (INIS)

    Haus, Arthur G.; Dickerson, Robert E.; Huff, Kenneth E.; Monte, Suzanne; Schlager, Barbara A.; Atanas, Meri; Matloubieh, Ahmad

    1996-01-01

    Purpose/Objective: A problem with conventional radiation therapy portal images is low image contrast, due in part to the low attenuation of the exposing radiation by the anatomical parts being imaged and the contrast capabilities of the film or screen-film combination. The purpose of this study was to design, develop and clinically evaluate a new screen-film combination for portal localization imaging which provides significantly higher contrast and therefore improved image quality. Materials and Methods: Comparison phantom and clinical images were made at two radiation oncology facilities with the new prototype screen-film combination and a commercial screen-film combination currently used for portal localization imaging. All images were made with linear accelerators at 6MV. Sensitometric data was also obtained. The prototype combination features a 1.0mm copper front screen plus front and back gadolinium oxysulfide fluorescent intensifying screens and a very-slow-speed film having inherently high contrast. The film emulsion layers are coated on a 7 mil Estar base which allows processing in a conventional rapid process film processor. For this combination, the film is exposed primarily by light from the intensifying screens. The current, commercially available screen-film combination was a Kodak X-Omatic L Radiation Therapy Cassette with a 1.0mm copper front screen and a 0.25mm lead back screen and Kodak X-Omat RP film in ready pack envelope. With this combination, the film emulsion is exposed by electrons generated in the metal screens. All films were processed in a Kodak M35A X-Omat processor. Radiation oncologists reviewed the phantom and clinical images. Results: Sensitometric data indicate that the film contrast (average gradient) of the new prototype combination is approximately 4 times higher than the conventional commercially available combination. Phantom and clinical comparisons at St. Mary Cancer Center, Langhorne PA. and the Daisy Marquis Jones

  3. Portal Hypertension

    Science.gov (United States)

    ... Overview of Gallbladder Cancer Additional Content Medical News Portal Hypertension By Steven K. Herrine, MD, Professor of Medicine, ... Liver Hepatic Encephalopathy Jaundice in Adults Liver Failure Portal Hypertension Portal hypertension is abnormally high blood pressure in ...

  4. Development of a New Analysis Tool for Evaluating and Correcting for Weather Conditions that Constrain Radiation Portal Monitor Performance

    International Nuclear Information System (INIS)

    Guzzardo, T.; Livesay, J.

    2011-01-01

    Researchers at Oak Ridge National Laboratory (ORNL) developed the Adaptable, Multiplatform, Real-Time Analysis Package (AMRAP) for the continuous measurement of environmental radionuclide decay. AMRAP is a completely open source visualization and analysis package capable of combining a variety of data streams into an array of real-time plots. Once acquired, data streams are analyzed to store static images and extract data based on previously defined thresholds. AMRAP is currently used at ORNL to combine data streams from an Ortec Detective high-purity germanium (HPGe) detector, a TSA Systems radiation portal monitor (RPM), and an Orion weather station. The combined data are used to study the rain-induced increase in RPM background radiation levels. RPMs experience an increase in background radiation during precipitation due to the deposition of atmospheric radionuclides on the ground. Using AMRAP results in a real-time analysis workstation specifically dedicated to the study of RPM background radiation levels. By means of an editable library of common inputs, AMRAP is adaptable to remote monitoring applications that would benefit from the real-time visualization and analysis of radiation measurements. To study rain-induced increases in background radiation levels observed in radiation portal monitors (RPMs), researchers at Oak Ridge National Laboratory (ORNL) developed a software package that allows data with different formats to be analyzed and plotted in near real time. The Adaptable, Multiplatform, Real-Time Analysis Package (AMRAP) was developed to operate in the background and capture plots of important data based on previously defined thresholds. After executing AMRAP, segments of a data stream can be captured without additional post-processing. AMRAP can also display previously recorded data to facilitate a detailed offline analysis. Without access to these capabilities in a single software package, analyzing multiple continuously recorded data streams with

  5. Verification of setup errors in external beam radiation therapy using electronic portal imaging

    International Nuclear Information System (INIS)

    Krishna Murthy, K.; Al-Rahbi, Zakiya; Sivakumar, S.S.; Davis, C.A.; Ravichandran, R.

    2008-01-01

    The objective of this study was to conduct an audit on QA aspects of treatment delivery by the verification of the treatment fields position on different days to document the efficiency of immobilization methods and reproducibility of treatment. A retrospective study was carried out on 60 patients, each 20 treated for head and neck, breast, and pelvic sites; and a total of 506 images obtained by electronic portal imaging device (EPID) were analyzed. The portal images acquired using the EPID systems attached to the Varian linear accelerators were superimposed on the reference images. The anatomy matching software (Varian portal Vision. 6.0) was used, and the displacements in two dimensions and rotation were noted for each treated field to study the patient setup errors. The percentages of mean deviations more than 3 mm in lateral (X) and longitudinal (Y) directions were 17.5%, 11.25%, and 7.5% for breast, pelvis, and head and neck cases respectively. In all cases, the percentage of mean deviation with more than 5 mm error was 0.83%. The maximum average mean deviation in all the cases was 1.87. The average mean SD along X and Y directions in all the cases was less than 2.65. The results revealed that the ranges of setup errors are site specific and immobilization methods improve reproducibility. The observed variations were well within the limits. The study confirmed the accuracy and quality of treatments delivered to the patients. (author)

  6. Interobserver Variability in Target Definition for Hepatocellular Carcinoma With and Without Portal Vein Thrombus: Radiation Therapy Oncology Group Consensus Guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Theodore S., E-mail: tshong1@mgh.harvard.edu [Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts (United States); Bosch, Walter R. [Department of Radiation Oncology, Washington University in St. Louis School of Medicine, St. Louis, Missouri (United States); Krishnan, Sunil [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Kim, Tae K. [Department of Medical Imaging, University Health Network, Mount Sinai Hospital and Women' s College Hospital, University of Toronto, Toronto, Ontario (Canada); Mamon, Harvey J. [Department of Radiation Oncology, Dana-Farber Cancer Institute/Brigham and Women' s Hospital and Harvard Medical School, Boston, Massachusetts (United States); Shyn, Paul [Department of Radiology, Brigham and Women' s Hospital and Harvard Medical School, Boston, Massachusetts (United States); Ben-Josef, Edgar [Department of Radiation Oncology, University of Pennsylvania School of Medicine, Philadelphia, Pennsylvania (United States); Seong, Jinsil [Department of Radiation Oncology, Yonsei University Medical College, Seoul (Korea, Republic of); Haddock, Michael G. [Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota (United States); Cheng, Jason C. [Department of Oncology, National Taiwan University Hospital, Taipei, Taiwan (China); Feng, Mary U. [Department of Radiation Oncology, University of Michigan Health System, Ann Arbor, Michigan (United States); Stephans, Kevin L. [Department of Radiation Oncology, Cleveland Clinic, Cleveland, Ohio (United States); Roberge, David [Department of Radiation Oncology, Montreal General Hospital/McGill University Health Centre, Montreal, Quebec (Canada); Crane, Christopher [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); and others

    2014-07-15

    Purpose: Defining hepatocellular carcinoma (HCC) gross tumor volume (GTV) requires multimodal imaging, acquired in different perfusion phases. The purposes of this study were to evaluate the variability in contouring and to establish guidelines and educational recommendations for reproducible HCC contouring for treatment planning. Methods and Materials: Anonymous, multiphasic planning computed tomography scans obtained from 3 patients with HCC were identified and distributed to a panel of 11 gastrointestinal radiation oncologists. Panelists were asked the number of HCC cases they treated in the past year. Case 1 had no vascular involvement, case 2 had extensive portal vein involvement, and case 3 had minor branched portal vein involvement. The agreement between the contoured total GTVs (primary + vascular GTV) was assessed using the generalized kappa statistic. Agreement interpretation was evaluated using Landis and Koch's interpretation of strength of agreement. The S95 contour, defined using the simultaneous truth and performance level estimation (STAPLE) algorithm consensus at the 95% confidence level, was created for each case. Results: Of the 11 panelists, 3 had treated >25 cases in the past year, 2 had treated 10 to 25 cases, 2 had treated 5 to 10 cases, 2 had treated 1 to 5 cases, 1 had treated 0 cases, and 1 did not respond. Near perfect agreement was seen for case 1, and substantial agreement was seen for cases 2 and 3. For case 2, there was significant heterogeneity in the volume identified as tumor thrombus (range 0.58-40.45 cc). For case 3, 2 panelists did not include the branched portal vein thrombus, and 7 panelists contoured thrombus separately from the primary tumor, also showing significant heterogeneity in volume of tumor thrombus (range 4.52-34.27 cc). Conclusions: In a group of experts, excellent agreement was seen in contouring total GTV. Heterogeneity exists in the definition of portal vein thrombus that may impact treatment

  7. The response of thrombosis in the portal vein or hepatic vein in hepatocellular carcinoma to radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Bong Kyung; Kim, Jae Chul [Dept. of Radiation Oncology, Kyungpook National University School of Medicine, Daegu (Korea, Republic of)

    2016-09-15

    The purpose of current study is to evaluate the response of the patients with portal vein thrombosis (PVT) or hepatic vein thrombosis (HVT) in hepatocellular carcinoma (HCC) treated with three-dimensional conformal radiation therapy (3D-CRT). In addition, survival of patients and potential prognostic factors of the survival was evaluated. Forty-seven patients with PVT or HVT in HCC, referred to our department for radiotherapy, were retrospectively reviewed. For 3D-CRT plans, a gross tumor volume (GTV) was defined as a hypodense filling defect area in the portal vein (PV) or hepatic vein (HV). Survival of patients, and response to radiation therapy (RT) were analyzed. Potential prognostic factors for survival and response to RT were evaluated. The median survival time of 47 patients was 8 months, with 1-year survival rate of 15% and response rate of 40%. Changes in Child-Pugh score, response to RT, Eastern cooperative oncology group performance status (ECOG PS), hepatitis C antibody (HCVAb) positivity, and additional post RT treatment were statistically significant prognostic factors for survival in univariate analysis (p = 0.000, p = 0.018, p = 0.000, p = 0.013, and p = 0.047, respectively). Of these factors, changes in Child-Pugh score, and response to RT were significant for patients' prognosis in multivariate analysis (p = 0.001 and p = 0.035, respectively). RT could constitute a reasonable treatment option for patients with PVT or HVT in HCC with acceptable toxicity. Changes in Child-Pugh score, and response to RT were statistically significant factors of survival of patients.

  8. Organic liquid scintillation detectors for on-the-fly neutron/gamma alarming and radionuclide identification in a pedestrian radiation portal monitor

    Science.gov (United States)

    Paff, Marc Gerrit; Ruch, Marc L.; Poitrasson-Riviere, Alexis; Sagadevan, Athena; Clarke, Shaun D.; Pozzi, Sara

    2015-07-01

    We present new experimental results from a radiation portal monitor based on the use of organic liquid scintillators. The system was tested as part of a 3He-free radiation portal monitor testing campaign at the European Commission's Joint Research Centre in Ispra, Italy, in February 2014. The radiation portal monitor was subjected to a wide range of test conditions described in ANSI N42.35, including a variety of gamma-ray sources and a 20,000 n/s 252Cf source. A false alarm test tested whether radiation portal monitors ever alarmed in the presence of only natural background. The University of Michigan Detection for Nuclear Nonproliferation Group's system triggered zero false alarms in 2739 trials. It consistently alarmed on a variety of gamma-ray sources travelling at 1.2 m/s at a 70 cm source to detector distance. The neutron source was detected at speeds up to 3 m/s and in configurations with up to 8 cm of high density polyethylene shielding. The success of on-the-fly radionuclide identification varied with the gamma-ray source measured as well as with which of two radionuclide identification methods was used. Both methods used a least squares comparison between the measured pulse height distributions to library spectra to pick the best match. The methods varied in how the pulse height distributions were modified prior to the least squares comparison. Correct identification rates were as high as 100% for highly enriched uranium, but as low as 50% for 241Am. Both radionuclide identification algorithms produced mixed results, but the concept of using liquid scintillation detectors for gamma-ray and neutron alarming in radiation portal monitor was validated.

  9. Viable dark matter via radiative symmetry breaking in a scalar singlet Higgs portal extension of the standard model.

    Science.gov (United States)

    Steele, T G; Wang, Zhi-Wei; Contreras, D; Mann, R B

    2014-05-02

    We consider the generation of dark matter mass via radiative electroweak symmetry breaking in an extension of the conformal standard model containing a singlet scalar field with a Higgs portal interaction. Generating the mass from a sequential process of radiative electroweak symmetry breaking followed by a conventional Higgs mechanism can account for less than 35% of the cosmological dark matter abundance for dark matter mass M(s)>80 GeV. However, in a dynamical approach where both Higgs and scalar singlet masses are generated via radiative electroweak symmetry breaking, we obtain much higher levels of dark matter abundance. At one-loop level we find abundances of 10%-100% with 106 GeVdark matter mass. The dynamical approach also predicts a small scalar-singlet self-coupling, providing a natural explanation for the astrophysical observations that place upper bounds on dark matter self-interaction. The predictions in all three approaches are within the M(s)>80 GeV detection region of the next generation XENON experiment.

  10. Roadside Tracker Portal-less Portal Monitor

    Energy Technology Data Exchange (ETDEWEB)

    Ziock, Klaus-Peter [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Cheriyadat, Anil M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Bradley, Eric Craig [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Cunningham, Mark F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Fabris, Lorenzo [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Goddard, Jr, James Samuel [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hornback, Donald Eric [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Karnowski, Thomas Paul [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Kerekes, Ryan A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Newby, Jason [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2013-07-01

    This report documents the full development cycle of the Roadside Tracker (RST) Portal-less Portal monitor (Fig. 1) funded by DHS DNDO. The project started with development of a proof-of-feasibility proto-type, proceeded through design and construction of a proof-of-concept (POC) prototype, a test-and-evaluation phase, participation in a Limited Use Exercise that included the Standoff Radiation Detections Systems developed under an Advanced Technology Demonstration and concluded with participation in a Characterization Study conducted by DNDO.

  11. Preliminary Study of Position-Sensitive Large-Area Radiation Portal Monitor

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Chang Hwy; Kim, Hyunok; Moon, Myung Kook [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Jongyul [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Park, Jong Won; Lim, Yong Kon [Korea Institute of Ocean Science and Technology, Daejeon (Korea, Republic of)

    2013-10-15

    An RPM, which is a passive inspection method, is a system for monitoring the movement of radioactive materials at an airport, seaport, border, etc. To detect a γ-ray, an RPM using the plastic scintillator is generally used. The method of γ-ray detection using an RPM with a plastic scintillator is to measure lights generated by an incident γ-ray in the scintillator. Generally, a large-area RPM uses one or two photomultiplier tubes (PMT) for light collection. However, in this study, we developed a 4-ch RPM that can measure the radiation signal using 4 PMTs. The reason for using 4 PMTs is to calculate the position of the radiation source. In addition, we developed an electric device for acquisition of a 4-ch output signal at the same time. To estimate the performance of the developed RPM, we performed an RPM test using a {sup 60}Co γ-ray check source. In this study, we performed the development of a 4-ch RPM. The major function of the typical RPM is to measure the radiation. However, we developed a position-sensitive 4-ch RPM, which can be used to measure the location of the radiation source, as well as the radiation measurement, at the same time. In the future, we plan to develop an algorithm for a position detection of the radiation. In addition, an algorithm will be applied to an RPM.

  12. A simple quality assurance test tool for the visual verification of light and radiation field congruent using electronic portal images device and computed radiography

    Directory of Open Access Journals (Sweden)

    Njeh Christopher F

    2012-03-01

    Full Text Available Abstract Background The radiation field on most megavoltage radiation therapy units are shown by a light field projected through the collimator by a light source mounted inside the collimator. The light field is traditionally used for patient alignment. Hence it is imperative that the light field is congruent with the radiation field. Method A simple quality assurance tool has been designed for rapid and simple test of the light field and radiation field using electronic portal images device (EPID or computed radiography (CR. We tested this QA tool using Varian PortalVision and Elekta iViewGT EPID systems and Kodak CR system. Results Both the single and double exposure techniques were evaluated, with double exposure technique providing a better visualization of the light-radiation field markers. The light and radiation congruency could be detected within 1 mm. This will satisfy the American Association of Physicists in Medicine task group report number 142 recommendation of 2 mm tolerance. Conclusion The QA tool can be used with either an EPID or CR to provide a simple and rapid method to verify light and radiation field congruence.

  13. A simple quality assurance test tool for the visual verification of light and radiation field congruent using electronic portal images device and computed radiography

    International Nuclear Information System (INIS)

    Njeh, Christopher F; Caroprese, Blas; Desai, Pushkar

    2012-01-01

    The radiation field on most megavoltage radiation therapy units are shown by a light field projected through the collimator by a light source mounted inside the collimator. The light field is traditionally used for patient alignment. Hence it is imperative that the light field is congruent with the radiation field. A simple quality assurance tool has been designed for rapid and simple test of the light field and radiation field using electronic portal images device (EPID) or computed radiography (CR). We tested this QA tool using Varian PortalVision and Elekta iViewGT EPID systems and Kodak CR system. Both the single and double exposure techniques were evaluated, with double exposure technique providing a better visualization of the light-radiation field markers. The light and radiation congruency could be detected within 1 mm. This will satisfy the American Association of Physicists in Medicine task group report number 142 recommendation of 2 mm tolerance. The QA tool can be used with either an EPID or CR to provide a simple and rapid method to verify light and radiation field congruence

  14. Evaluation of light Collection in Radiation Portal Monitor with Multi PMTs using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Lim, Chang Hwy; Park, Jong Won; Lee, Junghee; Moon, Myung Kook; Kim, Jongyul; Lee, Suhyun

    2015-01-01

    A plastic scintillator in the RPM is suited for the γ-ray detection of various-range energy and is the cost effective radiation detection material. In order to well inspect emitted radiation from the container cargo, the radiation detection area of a plastic scintillator should be larger than other general purpose radiation detector. However, the large size plastic scintillator affects the light collection efficiency at the photo-sensitive sensor due to the long light transport distance and light collisions in a plastic scintillator. Therefore, the improvement of light collection efficiency in a RPM is one of the major issues for the high performance RPM development. We calculated the change of the number of collected light according to changing of the attachment position and number of PMT. To calculate the number of collected light, the DETECT2000 and MCNP6 Monte Carlo simulation software tool was used. Response signal performance of RPM system is affected by the position of the incident radiation. If the distance between the radiation source and a PMT is long, the number of loss signal is larger. Generally, PMTs for signal detection in RPM system has been attached on one side of plastic scintillator. In contrast, RPM model in the study have 2 PMTs, which attached at the two side of plastic scintillator. We estimated difference between results using the old method and our method. According to results, uniformity of response signal was better than method using one side. If additive simulation and experiment is performed, it will be possible to develop the improved RPM system. In the future, we will perform additive simulation about many difference RPM model

  15. Evaluation of light Collection in Radiation Portal Monitor with Multi PMTs using Monte Carlo simulation

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Chang Hwy; Park, Jong Won; Lee, Junghee [Korea Research Institute of Ships and Ocean Engineering, Daejeon (Korea, Republic of); Moon, Myung Kook; Kim, Jongyul; Lee, Suhyun [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    A plastic scintillator in the RPM is suited for the γ-ray detection of various-range energy and is the cost effective radiation detection material. In order to well inspect emitted radiation from the container cargo, the radiation detection area of a plastic scintillator should be larger than other general purpose radiation detector. However, the large size plastic scintillator affects the light collection efficiency at the photo-sensitive sensor due to the long light transport distance and light collisions in a plastic scintillator. Therefore, the improvement of light collection efficiency in a RPM is one of the major issues for the high performance RPM development. We calculated the change of the number of collected light according to changing of the attachment position and number of PMT. To calculate the number of collected light, the DETECT2000 and MCNP6 Monte Carlo simulation software tool was used. Response signal performance of RPM system is affected by the position of the incident radiation. If the distance between the radiation source and a PMT is long, the number of loss signal is larger. Generally, PMTs for signal detection in RPM system has been attached on one side of plastic scintillator. In contrast, RPM model in the study have 2 PMTs, which attached at the two side of plastic scintillator. We estimated difference between results using the old method and our method. According to results, uniformity of response signal was better than method using one side. If additive simulation and experiment is performed, it will be possible to develop the improved RPM system. In the future, we will perform additive simulation about many difference RPM model.

  16. Design of a New Collimation System to Prevent Interference between X-ray Machines and Radiation Portal Monitors

    International Nuclear Information System (INIS)

    Guzzardo, Tyler; Livesay, Jake

    2012-01-01

    Researchers at Oak Ridge National Laboratory (ORNL) developed a new collimation system that allows radiation portal monitors (RPMs) installed near x-ray machines to operate with a negligible false-positive alarm rate. RPMs are usually installed as far as possible from x-ray machines because false alarms are triggered by escaping x-rays; however, constraints at the installation site sometimes make it necessary that RPMs be installed near x-ray machines. Such RPMs are often plagued by high alarm rates resulting from the simultaneous operation of the RPMs and x-ray machines. Limitations on pedestrian flow, x-ray machine orientation, and RPM location often preclude a simple solution for lowering the alarm rate. Adding additional collimation to the x-ray machines to stop the x-rays at the source can reduce the alarm rate without interfering with site operations or adversely affecting the minimum detectable quantity of material (MDQ). A collimation design has been verified by measurements conducted at a RPM installation site and is applicable to all new and existing RPM installations near x-ray machines.

  17. Comparison of horizontal and vertical noise power spectrum in measurements by using various electronic portal imaging devices in radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki Won [Dept. of Radiology, Kyung Hee University Hospital at Gang-dong, Seoul (Korea, Republic of); Choi, Kwan Woo [Dept. of Radiology, Asan Medical Center, Seoul (Korea, Republic of); Jeong, Hoi Woun [Dept. of Radiological Technology, Baekseok Culture University, Cheonan (Korea, Republic of); Jang, Seo Goo [Dept. of Medical Science, Soonchunhyang University, Asan (Korea, Republic of); Kwon, Kyung Tae [Dept. of Radiological Technology, Dongnam Health University, Suwon (Korea, Republic of); Son, Soon Yong [Dept. of Radiological Technology, Wonkwang Health Science University, Iksan (Korea, Republic of); Son, Jin Hyun; Min, Jung Whan [Dept. of Radiological Technology, Shingu University, Sungnam (Korea, Republic of)

    2016-06-15

    The quality assurance (QA) is very important for diagnostic field and radiation therapy field to evaluate the characteristic of devices. The purpose of this study was to compare different NPS methodologies results which are measuring NPS with regard to horizontal and vertical directions by using megavoltage X-ray energies. The NPS evaluation methods were applied to the International Electro-technical Commission standard (IEC 62220-1). The electronic portal imaging devices (EPID) devices such as Siemens BEAMVIEWPLUS, Elekta iViewGT and Varian ClinacR iX aS1000 were used. NPS data were expressed by corresponding each frequency about average of noise value corresponding the each frequency, and NPS were evaluated quantitatively by totaling up the noise values of average frequency which are on horizontal and vertical directions. In NPS results for Elekta iViewGT, NPS of horizontal and vertical by using 4 methods were indicated the difference of 3-5% between horizontal and vertical direction. In the results of Siemens BEAMVIEWPLUS and Varian ClinacR iX aS1000, the NPS of horizontal and vertical direction were indicated the difference of 15% when averaging the whole values. This study were evaluated the NPS of each devices by totaling up the noise values of average frequency which are on horizontal and vertical directions suggesting the quantitative evaluation method using the data.

  18. Dosimetric properties of an amorphous silicon electronic portal imaging device for verification of dynamic intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Greer, Peter B.; Popescu, Carmen C.

    2003-01-01

    Dosimetric properties of an amorphous silicon electronic portal imaging device (EPID) for verification of dynamic intensity modulated radiation therapy (IMRT) delivery were investigated. The EPID was utilized with continuous frame-averaging during the beam delivery. Properties studied included effect of buildup, dose linearity, field size response, sampling of rapid multileaf collimator (MLC) leaf speeds, response to dose-rate fluctuations, memory effect, and reproducibility. The dependence of response on EPID calibration and a dead time in image frame acquisition occurring every 64 frames were measured. EPID measurements were also compared to ion chamber and film for open and wedged static fields and IMRT fields. The EPID was linear with dose and dose rate, and response to MLC leaf speeds up to 2.5 cm s-1 was found to be linear. A field size dependent response of up to 5% relative to d max ion-chamber measurement was found. Reproducibility was within 0.8% (1 standard deviation) for an IMRT delivery recorded at intervals over a period of one month. The dead time in frame acquisition resulted in errors in the EPID that increased with leaf speed and were over 20% for a 1 cm leaf gap moving at 1.0 cm s-1. The EPID measurements were also found to depend on the input beam profile utilized for EPID flood-field calibration. The EPID shows promise as a device for verification of IMRT, the major limitation currently being due to dead-time in frame acquisition

  19. On line portal imaging

    International Nuclear Information System (INIS)

    Munro, Peter

    1996-01-01

    Purpose/Objective: The purpose of this presentation is to examine the various imaging devices that have been developed for portal imaging; describe some of the image registration methods that have been developed to determine geometric errors quantitatively; discuss some of the ways that portal imaging has been incorporated into routine clinical practice; describe quality assurance procedures for these devices, and discuss the use of portal imaging devices for dosimetry applications. Discussion: Verification of patient positioning has always been an important aspect of external beam radiation therapy. Over the past decade many portal imaging devices have been developed by individual investigators and most accelerator manufacturers now offer 'on-line' portal imaging systems. The commercial devices can be classified into three categories: T.V. camera-based systems, liquid ionisation chamber systems, and amorphous silicon systems. Many factors influence the quality of images generated by these portal imaging systems. These include factors which are unavoidable (e.g., low subject contrast), factors which depend upon the individual imaging device forming the image (e.g., dose utilisation, spatial resolution) as well as factors which depend upon the characteristics of the linear accelerator irradiating the imaging system (x-ray source size, image magnification). The characteristics of individual imaging systems, such as spatial resolution, temporal response, and quantum utilisation will be discussed. One of the major advantages of on-line portal imaging is that many quantitative techniques have been developed to detect errors in patient positioning. The general approach is to register anatomic structures on a portal image with the same structures on a digitized simulator film. Once the anatomic structures have been registered, any discrepancies in the position of the patient can be identified. However, the task is not nearly as straight-forward as it sounds. One problem

  20. On line portal imaging

    International Nuclear Information System (INIS)

    Munro, Peter

    1997-01-01

    Purpose/Objective: The purpose of this presentation is to examine the various imaging devices that have been developed for portal imaging, describe some of the image registration methods that have been developed to determine geometric errors quantitatively, and discuss how portal imaging has been incorporated into clinical practice. Discussion: Verification of patient positioning has always been an important aspect of external beam radiation therapy. Over the past decade many portal imaging devices have been developed by individual investigators and most accelerator manufacturers now offer 'on-line' portal imaging systems. The commercial devices include T.V. camera-based systems, liquid ionisation chamber systems, and shortly, flat panel systems. The characteristics of these imaging systems will be discussed. In addition, other approaches such as the use of kilovoltage x-ray sources, video monitoring, and ultrasound have been proposed for improving patient positioning. Some of the advantages of these approaches will be discussed. One of the major advantages of on-line portal imaging is that many quantitative techniques have been developed to detect errors in patient positioning. The general approach is to register anatomic structures on a portal image with the same structures on a digitized simulator film. Once the anatomic structures have been registered, any discrepancies in the position of the patient can be identified. One problem is finding a common frame of reference for the simulator and portal images, since the location of the radiation field within the pixel matrix may differ for the two images. As a result, a common frame of reference has to be established before the anatomic structures in the images can be registered - generally by registering radiation field edges identified in the simulator and portal images. In addition, distortions in patient geometry or rotations out of the image plane can confound the image registration techniques. Despite the

  1. GEO portal

    Data.gov (United States)

    US Agency for International Development — The USAID GeoPortal is a new application that groups web-based capabilities for on-demand discovery of and access to geospatial content, services, expertise, and...

  2. The radiation isocenter verification using an electronic system of image portal; Verificacion del isocentro de radiacion utilizando un sistema electronico de imagen portal

    Energy Technology Data Exchange (ETDEWEB)

    Merino Gestoso, J. A.; Portas Ferradas, B. C.; Rosa Menendez, P.; Chapel Gomez, M. L.; Fernandez Cerezo, S.; Vazquez Varela, P.

    2013-07-01

    In this paper we present a procedure optimized for verification the isocenter of radiation with respect to the rotation of the gantry and the turn isocentric table of two accelerators SIEMENS, ONCOR and ARTISTE with a mannequin developed in our service and analyzing the images acquired with the EPID from each of the teams. (Author)

  3. ASH External Web Portal (External Portal) -

    Data.gov (United States)

    Department of Transportation — The ASH External Web Portal is a web-based portal that provides single sign-on functionality, making the web portal a single location from which to be authenticated...

  4. The NUCLEONICA Nuclear Science Portal

    International Nuclear Information System (INIS)

    Magill, Joseph; Dreher, Raymond

    2009-01-01

    NUCLEONICA (www.nucleonica.net) is a new nuclear science web portal which provides a customisable, integrated environment and collaboration platform using the latest internet 'Web 2.0' technology. NUCLEONICA is aimed at professionals, academics and students working in nuclear power, health physics and radiation protection, nuclear and radio-chemistry, and astrophysics. A unique feature of the portal is the wide range of user friendly web-based nuclear science applications. The portal is also ideal for education and training purposes and as a knowledge management platform to preserve nuclear knowledge built up over many decades.

  5. Portal Vein Thrombosis

    Directory of Open Access Journals (Sweden)

    Hakan Demirci

    2016-01-01

    Full Text Available Portal vein thrombosis is an important cause of presinusoidal portal hypertension. Portal vein thrombosis commonly occurs in patient with cirrhosis, malignancy and prothrombotic states. Patients with acute portal vein thrombosis have immediate onset. Patients with chronic portal vein thrombosis have developed portal hypertension and cavernous portal transformation. Portal vein thrombosis is diagnosed with doppler ultrasound, computed tomography and magnetic resonance imaging. Therapy with low molecular weight heparin achieves recanalization in more than half of acute cases.

  6. Portal manga

    OpenAIRE

    Temprano Hernandez, Joan

    2011-01-01

    El projecte Portal Manga pretén construir una aplicació web que ha de permetre a una empresa anunciar els seus productes a la web, disposar de una botiga virtual en la que es puguin adquirir aquests productes en format digital i finalment un lector web que en permeti la lectura online.

  7. Electronic portal imaging devices

    International Nuclear Information System (INIS)

    Lief, Eugene

    2008-01-01

    The topics discussed include, among others, the following: Role of portal imaging; Port films vs. EPID; Image guidance: Elekta volume view; Delivery verification; Automation tasks of portal imaging; Types of portal imaging (Fluorescent screen, mirror, and CCD camera-based imaging; Liquid ion chamber imaging; Amorpho-silicon portal imagers; Fluoroscopic portal imaging; Kodak CR reader; and Other types of portal imaging devices); QA of EPID; and Portal dosimetry (P.A.)

  8. SU-F-T-486: A Simple Approach to Performing Light Versus Radiation Field Coincidence Quality Assurance Using An Electronic Portal Imaging Device (EPID)

    Energy Technology Data Exchange (ETDEWEB)

    Herchko, S; Ding, G [Vanderbilt University, Nashville, TN (United States)

    2016-06-15

    Purpose: To develop an accurate, straightforward, and user-independent method for performing light versus radiation field coincidence quality assurance utilizing EPID images, a simple phantom made of readily-accessible materials, and a free software program. Methods: A simple phantom consisting of a blocking tray, graph paper, and high-density wire was constructed. The phantom was used to accurately set the size of a desired light field and imaged on the electronic portal imaging device (EPID). A macro written for use in ImageJ, a free image processing software, was then use to determine the radiation field size utilizing the high density wires on the phantom for a pixel to distance calibration. The macro also performs an analysis on the measured radiation field utilizing the tolerances recommended in the AAPM Task Group #142. To verify the accuracy of this method, radiochromic film was used to qualitatively demonstrate agreement between the film and EPID results, and an additional ImageJ macro was used to quantitatively compare the radiation field sizes measured both with the EPID and film images. Results: The results of this technique were benchmarked against film measurements, which have been the gold standard for testing light versus radiation field coincidence. The agreement between this method and film measurements were within 0.5 mm. Conclusion: Due to the operator dependency associated with tracing light fields and measuring radiation fields by hand when using film, this method allows for a more accurate comparison between the light and radiation fields with minimal operator dependency. Removing the need for radiographic or radiochromic film also eliminates a reoccurring cost and increases procedural efficiency.

  9. SU-F-T-486: A Simple Approach to Performing Light Versus Radiation Field Coincidence Quality Assurance Using An Electronic Portal Imaging Device (EPID)

    International Nuclear Information System (INIS)

    Herchko, S; Ding, G

    2016-01-01

    Purpose: To develop an accurate, straightforward, and user-independent method for performing light versus radiation field coincidence quality assurance utilizing EPID images, a simple phantom made of readily-accessible materials, and a free software program. Methods: A simple phantom consisting of a blocking tray, graph paper, and high-density wire was constructed. The phantom was used to accurately set the size of a desired light field and imaged on the electronic portal imaging device (EPID). A macro written for use in ImageJ, a free image processing software, was then use to determine the radiation field size utilizing the high density wires on the phantom for a pixel to distance calibration. The macro also performs an analysis on the measured radiation field utilizing the tolerances recommended in the AAPM Task Group #142. To verify the accuracy of this method, radiochromic film was used to qualitatively demonstrate agreement between the film and EPID results, and an additional ImageJ macro was used to quantitatively compare the radiation field sizes measured both with the EPID and film images. Results: The results of this technique were benchmarked against film measurements, which have been the gold standard for testing light versus radiation field coincidence. The agreement between this method and film measurements were within 0.5 mm. Conclusion: Due to the operator dependency associated with tracing light fields and measuring radiation fields by hand when using film, this method allows for a more accurate comparison between the light and radiation fields with minimal operator dependency. Removing the need for radiographic or radiochromic film also eliminates a reoccurring cost and increases procedural efficiency.

  10. On line portal imaging

    International Nuclear Information System (INIS)

    Munro, Peter

    1995-01-01

    Purpose/Objective: The purpose of this presentation is to review the physics of imaging with high energy x-ray beams; examine the various imaging devices that have been developed for portal imaging; describe some of the image registration methods that have been developed to determine errors in patient positioning quantitatively; and discuss some of the ways that portal imaging has been incorporated into routine clinical practice. Verification of patient positioning has always been an important aspect of external beam radiation therapy. Checks of patient positioning have generally been done with film, however, film suffers from a number of drawbacks, such as poor image display and delays due to film development. Over the past decade many portal imaging devices have been developed by individual investigators and most accelerator manufacturers now offer 'on-line' portal imaging systems, which are intended to overcome the limitations of portal films. The commercial devices can be classified into three categories: T.V. camera-based systems, liquid ionisation chamber systems, and amorphous silicon systems. Many factors influence the quality of images generated by these portal imaging systems. These include factors which are unavoidable (e.g., low subject contrast), factors which depend upon the individual imaging device forming the image (e.g., dose utilisation, spatial resolution) as well as factors which depend upon the characteristics of the linear accelerator irradiating the imaging system (x-ray source size, image magnification). The fundamental factors which limit image quality and the characteristics of individual imaging systems, such as spatial resolution, temporal response, and quantum utilisation will be discussed. One of the major advantages of on-line portal imaging is that many quantitative techniques have been developed to detect errors in patient positioning. The general approach is to register anatomic structures on a portal image with the same

  11. Noncirrotisk intrahepatisk portal hypertension

    DEFF Research Database (Denmark)

    Dam Fialla, Annette; Havelund, Troels

    2007-01-01

    Non-cirrhotic intrahepatic portal hypertension is characterized by portal hypertension in the absence of liver cirrhosis or portal vein thrombosis. The disease is common in the East and rarely seen in the West. Two cases with oesophageal varices are described. The histopathology is heterogeneous...... but includes vascular lesions and portal fibrosis. Patient management follows the current recommendations for variceal bleeding....

  12. Radiation portal monitor with {sup 10}B+ZnS(Ag) neutron detector performance for the detection of special nuclear materials

    Energy Technology Data Exchange (ETDEWEB)

    Guzman G, K. A.; Gallego, E.; Lorente, A.; Ibanez F, S. [Universidad Politecnica de Madrid, Departamento de Ingenieria Energetica, ETSI Industriales, C. Jose Gutierrez Abascal 2, 28006 Madrid (Spain); Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas, Zac. (Mexico); Gonzalez, J. A. [Universidad Politecnica de Madrid, Laboratorio de Ingenieria Nuclear, ETSI Caminos, Canales y Puertos, C. Prof. Aranguren 3, 28040 Madrid (Spain); Mendez, R., E-mail: ingkarenguzman@gmail.com [Centro de Investigaciones Energeticas, Medioambientales y Tecnologicas, Laboratorio de Patrones Neutronicos, Av. Complutense 40, 28040 Madrid (Spain)

    2016-10-15

    In homeland security, neutron detection is used to prevent the smuggling of special nuclear materials. Thermal neutrons are normally detected with {sup 3}He proportional counters, in the radiation portal monitors, Rpms, however due to the {sup 3}He shortage new procedures are being studied. In this work Monte Carlo methods, using the MCNP6 code, have been used to study the neutron detection features of a {sup 10}B+ZnS(Ag) under real conditions inside of a Rpm. The performance for neutron detection was carried out for {sup 252}Cf, {sup 238}U and {sup 239}Pu under different conditions. In order to mimic an actual situation occurring at border areas, a sample of SNM sited inside a vehicle was simulated and the Rpm with {sup 10}B+ZnS(Ag) response was calculated. At 200 cm the {sup 10}B+ZnS(Ag) on Rpm response is close to 2.5 cps-ng {sup 252}Cf, when the {sup 252}Cf neutron source is shielded with 0.5 cm-thick lead and 2.5 cm-thick polyethylene fulfilling the ANSI recommendations. Three different geometries of neutron detectors of {sup 10}B+ZnS(Ag) in a neutron detection system in Rpm were modeled. Therefore, the {sup 10}B+ZnS(Ag) detectors are an innovative and viable replacement for the {sup 3}He detectors in the Rpm. (Author)

  13. Radiation portal monitor with "1"0B+ZnS(Ag) neutron detector performance for the detection of special nuclear materials

    International Nuclear Information System (INIS)

    Guzman G, K. A.; Gallego, E.; Lorente, A.; Ibanez F, S.; Vega C, H. R.; Gonzalez, J. A.; Mendez, R.

    2016-10-01

    In homeland security, neutron detection is used to prevent the smuggling of special nuclear materials. Thermal neutrons are normally detected with "3He proportional counters, in the radiation portal monitors, Rpms, however due to the "3He shortage new procedures are being studied. In this work Monte Carlo methods, using the MCNP6 code, have been used to study the neutron detection features of a "1"0B+ZnS(Ag) under real conditions inside of a Rpm. The performance for neutron detection was carried out for "2"5"2Cf, "2"3"8U and "2"3"9Pu under different conditions. In order to mimic an actual situation occurring at border areas, a sample of SNM sited inside a vehicle was simulated and the Rpm with "1"0B+ZnS(Ag) response was calculated. At 200 cm the "1"0B+ZnS(Ag) on Rpm response is close to 2.5 cps-ng "2"5"2Cf, when the "2"5"2Cf neutron source is shielded with 0.5 cm-thick lead and 2.5 cm-thick polyethylene fulfilling the ANSI recommendations. Three different geometries of neutron detectors of "1"0B+ZnS(Ag) in a neutron detection system in Rpm were modeled. Therefore, the "1"0B+ZnS(Ag) detectors are an innovative and viable replacement for the "3He detectors in the Rpm. (Author)

  14. Idiopathic portal hypertension

    International Nuclear Information System (INIS)

    Han, Tae Kyun; Ryu, Dae Sik; Kim, Heung Chul; Hur, Hun; Eom, Kyeung Tae; Namkung, Sook; Park, Man Soo; Hwang, Woo Chul; Lee, Kwan Seop

    1996-01-01

    To describe the radiologic findings of idiopathic portal hypertension and to find the points of differentiation between idiopathic portal hypertension and liver cirrhosis. Four portograms in five patients who for four years had suffered from pathologically confirmed idiopathic portal hypertension were retrospectively analyzed and compared with a portogram obtained from a control subject with liver cirrhosis. Portographic finding s of idiopathic portal hypertension were paucity of medium-sized portal branches, irregular and obtuse-angled division of peripheral branches, abrupt interruption and an avascular area beneath the liver margin. A portogram of idiopathic portal hypertension may be useful in differentiation this and liver cirrhosis

  15. Rare Disease Video Portal

    OpenAIRE

    Sánchez Bocanegra, Carlos Luis

    2011-01-01

    Rare Disease Video Portal (RD Video) is a portal web where contains videos from Youtube including all details from 12 channels of Youtube. Rare Disease Video Portal (RD Video) es un portal web que contiene los vídeos de Youtube incluyendo todos los detalles de 12 canales de Youtube. Rare Disease Video Portal (RD Video) és un portal web que conté els vídeos de Youtube i que inclou tots els detalls de 12 Canals de Youtube.

  16. Hepatic arterial phase and portal venous phase computed tomography for dose calculation of stereotactic body radiation therapy plans in liver cancer: a dosimetric comparison study

    International Nuclear Information System (INIS)

    Xiao, Jianghong; Li, Yan; Jiang, Qingfeng; Sun, Lan; Henderson Jr, Fraser; Wang, Yongsheng; Jiang, Xiaoqin; Li, Guangjun; Chen, Nianyong

    2013-01-01

    To investigate the effect of computed tomography (CT) using hepatic arterial phase (HAP) and portal venous phase (PVP) contrast on dose calculation of stereotactic body radiation therapy (SBRT) for liver cancer. Twenty-one patients with liver cancer were studied. HAP, PVP and non-enhanced CTs were performed on subjects scanned in identical positions under active breathing control (ABC). SBRT plans were generated using seven-field three-dimensional conformal radiotherapy (7 F-3D-CRT), seven-field intensity-modulated radiotherapy (7 F-IMRT) and single-arc volumetric modulated arc therapy (VMAT) based on the PVP CT. Plans were copied to the HAP and non-enhanced CTs. Radiation doses calculated from the three phases of CTs were compared with respect to the planning target volume (PTV) and the organs at risk (OAR) using the Friedman test and the Wilcoxon signed ranks test. SBRT plans calculated from either PVP or HAP CT, including 3D-CRT, IMRT and VMAT plans, demonstrated significantly lower (p <0.05) minimum absorbed doses covering 98%, 95%, 50% and 2% of PTV (D98%, D95%, D50% and D2%) than those calculated from non-enhanced CT. The mean differences between PVP or HAP CT and non-enhanced CT were less than 2% and 1% respectively. All mean dose differences between the three phases of CTs for OARs were less than 2%. Our data indicate that though the differences in dose calculation between contrast phases are not clinically relevant, dose underestimation (IE, delivery of higher-than-intended doses) resulting from CT using PVP contrast is larger than that resulting from CT using HAP contrast when compared against doses based upon non-contrast CT in SBRT treatment of liver cancer using VMAT, IMRT or 3D-CRT

  17. Comparison of noise power spectrum methodologies in measurements by using various electronic portal imaging devices in radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Son, Soon Yong [Dept. of Radiological Technology, Wonkwang Health Science University, Iksan (Korea, Republic of); Choi, Kwan Woo [Dept. of Radiology, Asan Medical Center, Seoul (Korea, Republic of); Jeong, Hoi Woun [Dept. of Radiological Technology, Baekseok Culture University College, Cheonan (Korea, Republic of); Kwon, Kyung Tae [Dep. of Radiological Technology, Dongnam Health University, Suwon (Korea, Republic of); Kim, Ki Won [Dept. of Radiology, Kyung Hee University Hospital at Gang-dong, Seoul (Korea, Republic of); Lee, Young Ah; Son, Jin Hyun; Min, Jung Whan [Shingu University College, Sungnam (Korea, Republic of)

    2016-03-15

    The noise power spectrum (NPS) is one of the most general methods for measuring the noise amplitude and the quality of an image acquired from a uniform radiation field. The purpose of this study was to compare different NPS methodologies by using megavoltage X-ray energies. The NPS evaluation methods in diagnostic radiation were applied to therapy using the International Electro-technical Commission standard (IEC 62220-1). Various radiation therapy (RT) devices such as TrueBeamTM(Varian), BEAMVIEWPLUS(Siemens), iViewGT(Elekta) and ClinacR iX (Varian) were used. In order to measure the region of interest (ROI) of the NPS, we used the following four factors: the overlapping impact, the non-overlapping impact, the flatness and penumbra. As for NPS results, iViewGT(Elekta) had the higher amplitude of noise, compared to BEAMVIEWPLUS (Siemens), TrueBeamTM(Varian) flattening filter, ClinacRiXaS1000(Varian) and TrueBeamTM(Varian) flattening filter free. The present study revealed that various factors could be employed to produce megavoltage imaging (MVI) of the NPS and as a baseline standard for NPS methodologies control in MVI.

  18. The Knowledge Portal

    Data.gov (United States)

    Office of Personnel Management — Information on various courses, as well as personal data of employees and training records from The Knowledge Portal (TKP), a web-based training portal used for the...

  19. Usability of Discovery Portals

    NARCIS (Netherlands)

    Bulens, J.D.; Vullings, L.A.E.; Houtkamp, J.M.; Vanmeulebrouk, B.

    2013-01-01

    As INSPIRE progresses to be implemented in the EU, many new discovery portals are built to facilitate finding spatial data. Currently the structure of the discovery portals is determined by the way spatial data experts like to work. However, we argue that the main target group for discovery portals

  20. Portals people, processes, technology

    CERN Document Server

    Cox, Andrew

    2006-01-01

    First applied to internet gateways such as Yahoo, the concept of the ""portal"" has evolved in a number of directions. How can information services best take advantage of internet portals to improve access to resources? This collection seeks answers to such questions, providing an overview of how portals are being used.

  1. Monitoring system for gamma radiation of porch type for vehicles; Sistema de monitoreo de radiacion gamma tipo portal para vehiculos

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez C, R.M.; Molina, G.; Gutierrez O, E.; Ramirez J, F.J.; Garcia H, J.M.; Aguilar B, M.A.; Vilchis P, A.E.; Cruz E, P.; Torres B, M.A. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2005-07-01

    A monitoring system of gamma radiation for vehicles of the porch type developed in the ININ is presented. This system carries out the radiological monitoring of the vehicles in continuous form, detecting the bottom radiological environment and the presence of nuclear material transported in vehicles. The vehicles are monitored while they pass to low speed through the porch. The detectors are plastic scintillators of great volume that allow high sensibility detection. The arrangement of detecting is interconnected in net, and the data are concentrated on a personal computer whose interface man-machine can be accessed from any personal computer connected to Internet. The system monitoring in real time with options of sampling times from 50 ms configurable up to 500 ms. (Author)

  2. Single-portal-phase low-tube-voltage dual-energy CT for short-term follow-up of acute pancreatitis: evaluation of CT severity index, interobserver agreement and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Wichmann, Julian L. [University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt am Main (Germany); Universitaetsklinikum Frankfurt, Institut fuer Diagnostische und Interventionelle Radiologie, Frankfurt am Main (Germany); Majenka, Pawel; Beeres, Martin; Kromen, Wolfgang; Schulz, Boris; Bauer, Ralf W.; Kerl, J.M.; Gruber-Rouh, Tatjana; Hammerstingl, Renate; Vogl, Thomas J.; Lehnert, Thomas [University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt am Main (Germany); Wesarg, Stefan [Fraunhofer IGD, Cognitive Computing and Medical Imaging, Darmstadt (Germany)

    2014-11-15

    To intra-individually compare single-portal-phase low-tube-voltage (100-kVp) computed tomography (CT) with 120-kVp images for short-term follow-up assessment of CT severity index (CTSI) of acute pancreatitis, interobserver agreement and radiation dose. We retrospectively analysed 66 patients with acute pancreatitis who underwent initial dual-contrast-phase CT (unenhanced, arterial, portal phase) at admission and short-term (mean interval 11.4 days) follow-up dual-contrast-phase dual-energy CT. The 100-kVp and linearly blended images representing 120-kVp acquisition follow-up CT images were independently evaluated by three radiologists using a modified CTSI assessing pancreatic inflammation, necrosis and extrapancreatic complications. Scores were compared with paired t test and interobserver agreement was evaluated using intraclass correlation coefficients (ICC). Mean CTSI scores on unenhanced, portal- and dual-contrast-phase images were 4.9, 6.1 and 6.2 (120 kVp) and 5.0, 6.0 and 6.1 (100 kVp), respectively. Contrast-enhanced series showed a higher CTSI compared to unenhanced images (P < 0.05) but no significant differences between single- and dual-contrast-phase series (P > 0.7). CTSI scores were comparable for 100-kVp and 120-kVp images (P > 0.05). Interobserver agreement was substantial for all evaluated series and subcategories (ICC 0.67-0.93). DLP of single-portal-phase 100-kVp images was reduced by 41 % compared to 120-kVp images (363.8 versus 615.9 mGy cm). Low-tube-voltage single-phase 100-kVp CT provides sufficient information for follow-up evaluation of acute pancreatitis and significantly reduces radiation exposure. (orig.)

  3. Portal hypertensiv gastropati

    DEFF Research Database (Denmark)

    Brinch, K; Møller, S; Henriksen, Jens Henrik Sahl

    1995-01-01

    Portal hypertensive gastropathy (PHG) as defined by congestive changes in the gastric mucosa owing to increased portal pressure, was first described about ten years ago. Whereas definition and grading of severity are still under debate, there is general agreement that PHG is a new clinical entity....... PHG is present in 50-80% of patients with liver cirrhosis. PHG is a major cause of upper gastrointestinal bleeding in patients with portal hypertension (25-90% depending on severity). Presence of portal hypertension is a prerequisite for the development of PHG, and reduction of portal pressure...

  4. Mobile Portal Implementation Strategy

    DEFF Research Database (Denmark)

    Gao, Ping; Damsgaard, Jan

    2005-01-01

    Mobile portal plays an important role in mobile commerce market. Current literature focuses on static analysis on the value chain of mobile portals. This article provides a dynamic perspective on mobile portal strategy. Drawing upon network economics, we describe mobile portal implementation...... as a fourphase process. In different phase, a portal provider has various challenges to overcome and adopt diverse strategies, and correspondingly the regulator has different foci. The conceptual framework proposed in this article offers a basis for further analyses on the market dynamics of mobile commerce......, and can be generalized to studying other networked technologies...

  5. Quantitative vs. subjective portal verification using digital portal images.

    Science.gov (United States)

    Bissett, R; Leszczynski, K; Loose, S; Boyko, S; Dunscombe, P

    1996-01-15

    Off-line, computer-aided prescription (simulator) and treatment (portal) image registration using chamfer matching has been implemented on PC based viewing station. The purposes of this study were (a) to evaluate the performance of interactive anatomy and field edge extraction and subsequent registration, and (b) to compare observer's perceptions of field accuracy with measured discrepancies following anatomical registration. Prescription-treatment image pairs for 48 different patients were examined in this study. Digital prescription images were produced with the aid of a television camera and a digital frame grabber, while the treatment images were obtained directly from an on-line portal imaging system. To facilitate perception of low contrast anatomical detail, on-line portal images were enhanced with selective adaptive histogram equalization prior to extraction of anatomical edges. Following interactive extraction of anatomical and field border information by an experienced observer, the identified anatomy was registered using chamfer matching. The degree of conformity between the prescription and treatment fields was quantified using several parameters, which included relative prescription field coverage and overcoverage, as well as the translational and rotational displacements as measured by chamfer matching applied to the boundaries of the two fields. These quantitative measures were compared with subjective evaluations made by four radiation oncologists. All the images in this series that included a range of the most commonly seen treatment sites were registered and the conformity parameters were found. The mean treatment/prescription field coverage and overcoverage were approximately 95 and 7%, respectively before registration. The mean translational displacement in the transverse and cranio-caudal directions were 2.9 and 3.4 mm, respectively. The mean rotational displacement was approximately 2 degrees. For all four oncologists, the portals classified

  6. NUCLEONICA: a nuclear science portal

    International Nuclear Information System (INIS)

    Magill, J.; Galy, J.; Dreher, R.; Hamilton, D.; Tufan, M.; Normand, C.; Schwenk-Ferrero, A.; Wiese, H.W.

    2008-01-01

    NUCLEONICA is a new nuclear science web portal from the European Commission's Joint Research Centre. The portal provides a customizable, integrated environment and collaboration platform for the nuclear sciences using the latest 'Web 2.0' dynamic technology. NUCLEONICA is aimed at professionals, academics and students working with radionuclides in fields as diverse as the life sciences (e.g., biology, medicine, agriculture), the earth sciences (geology, meteorology, environmental science) and the more traditional disciplines such as nuclear power, health physics and radiation protection, nuclear and radio-chemistry, and astrophysics. It is also used as a knowledge management tool to preserve nuclear knowledge built up over many decades by creating modern web-based versions of so-called legacy computer codes. (authors)

  7. Noncirrhotic portal hypertension.

    Science.gov (United States)

    Da, Ben L; Koh, Christopher; Heller, Theo

    2018-05-01

    Noncirrhotic portal hypertension represents a heterogeneous group of liver disorders that is characterized by portal hypertension in the absence of cirrhosis. The purpose of this review is to serve as a guide on how to approach a patient with noncirrhotic portal hypertension with a focus on recent developments. Recent studies pertaining to noncirrhotic portal hypertension have investigated aetiological causes, mechanisms of disease, noninvasive diagnostic modalities, clinical characteristics in the paediatric population and novel treatment targets. Noncirrhotic portal hypertension is an underappreciated clinical entity that can be difficult to diagnosis without a healthy suspicion. Diagnosis then relies on a comprehensive understanding of the causes and clinical manifestations of this disease, as well as a careful interpretation of the liver biopsy. Noninvasive approaches to diagnosis may play a significant role moving forward in this disease. Treatment in NCPH remains largely targeted at the individual sequalae of portal hypertension.

  8. Hepatic angiography: Portal hypertension

    International Nuclear Information System (INIS)

    Oliver, T.W. Jr.; Sones, P.J. Jr.

    1985-01-01

    Portal hypertension is usually a manifestation of underlying hepatic parenchymal disease, although it may be secondary to portal or hepatic venous thrombosis and rarely to hyperdynamic portal states. Portal hypertension may present as encephalopathy, ascites, jaundice, hepatic failure, or catastrophic upper gastrointestinal hemorrhage. Radiologic investigation should include indirect or direct measurements of portal pressure, assessment of portal venous perfusion, visualization of collaterals, and demonstration of arterial and venous anatomy for potential shunt procedure. Following survival of initial variceal bleeding, the most effective procedure to prevent recurrent hemorrhage is a shunt to decompress the varices. The decision whether to intervene medically or surgically during the acute hemorrhagic episode as well as the type of shunt used to prevent future hemorrhage is the subject of continuing controversy

  9. Pediatric portal hypertension

    Science.gov (United States)

    Vogel, Clarissa Barbon

    2017-01-01

    Abstract: Pediatric portal hypertension management is a team approach between the patient, the patient's family, the primary caregiver, and specialty providers. Evidence-based practice guidelines have not been established in pediatrics. This article serves as a review for the primary care NP in the management of pediatric portal hypertension, discussing the etiology, pathophysiology, and clinical presentation of pediatric portal hypertension, diagnostic tests, and treatment and management options. PMID:28406835

  10. Usability of Discovery Portals

    OpenAIRE

    Bulens, J.D.; Vullings, L.A.E.; Houtkamp, J.M.; Vanmeulebrouk, B.

    2013-01-01

    As INSPIRE progresses to be implemented in the EU, many new discovery portals are built to facilitate finding spatial data. Currently the structure of the discovery portals is determined by the way spatial data experts like to work. However, we argue that the main target group for discovery portals are not spatial data experts but professionals with limited spatial knowledge, and a focus outside the spatial domain. An exploratory usability experiment was carried out in which three discovery p...

  11. Ultrasound and Doppler examination capabilities in adult portal hypertension type definition

    Directory of Open Access Journals (Sweden)

    N. V. Tumanskaya

    2015-08-01

    Full Text Available Early portal hypertension type diagnostics is an ultimate factor concerning kind and tactics of treatment. Aim. To objectify ultrasound examination capabilities, portal hemodynamics were studied in 97 patients using impulse and color doppler. Methods and results. It was ascertained that impulse and color doppler examination allows to visualize portal vein and its branches’ structural abnormalities, define subhepatic and intrahepatic types of portal hypertension, find thrombosis and characterize its stages. In cirrhosis patients with portal hypertension, homogenous doppler signal was received from the portal vessels lumen, while signs of intraluminar pathology were seen in the case of thrombosis of portal vein. Conclusion. This means that ultrasound examination of portal vein and its branches with impulse and color doppler is informative, non invasive method, which helps to define stages of portal hypertension. Doppler ultrasonography doesn’t have negative effect of ionizing radiation and can be used for the repeated research in the dynamics of disease.

  12. Portal cholangiopathy: case report

    Directory of Open Access Journals (Sweden)

    Maria Cecilia Almeida Maia

    2014-01-01

    Full Text Available The present report describes the case of a child that after blunt abdominal trauma presented with portal thrombosis followed by progressive splenomegaly and jaundice. Ultrasonography and percutaneous cholangiography revealed biliary dilatation secondary to choledochal stenosis caused by dilated peribiliary veins, characterizing a case of portal biliopathy. The present case report is aimed at presenting an uncommon cause of this condition.

  13. The XCAT Science Portal

    Directory of Open Access Journals (Sweden)

    Sriram Krishnan

    2002-01-01

    Full Text Available This paper describes the design and prototype implementation of the XCAT Grid Science Portal. The portal lets grid application programmers script complex distributed computations and package these applications with simple interfaces for others to use. Each application is packaged as a notebook which consists of web pages and editable parameterized scripts. The portal is a workstation-based specialized personal web server, capable of executing the application scripts and launching remote grid applications for the user. The portal server can receive event streams published by the application and grid resource information published by Network Weather Service (NWS [35] or Autopilot [16] sensors. Notebooks can be published and stored in web based archives for others to retrieve and modify. The XCAT Grid Science Portal has been tested with various applications, including the distributed simulation of chemical processes in semiconductor manufacturing and collaboratory support for X-ray crystallographers.

  14. Schistosoma mansoni: quantitative aspects of the evolution of gamma-radiation cercariae at the skin, lungs and portal system, in mice

    International Nuclear Information System (INIS)

    Sa Cardoso, G. de; Coelho, P.M.Z.

    1989-01-01

    The migration of Schistosoma mansoni (LE and SJ strains) has been studied in eight groups of outbred Swiss albino mice (Mus musculus), which were previously infected with ca 450 cercariae, trans-cutaneously. The infection of mice was performed with non irradiated cercariae (control groups), or with gamma-irradiated cercariae, at the schedule of 3, 20 and 40 Krad. Regarding the skin, a progressive decrease was detected for the recovery rates, related to the time of infection. As far as the lungs and portal system are concerned, a significant inverse correlation was observed between the total recovery rate and the irradiation dosages. The dose of 20 Krad practically hinders the migration of the parasites (in both strains) from the lungs to the portal system, whereas the dose of 40 Krad prevents the migration of most of the parasites from the skin to the lungs. (author)

  15. Portal Vein Stenting for Portal Biliopathy with Jaundice

    Energy Technology Data Exchange (ETDEWEB)

    Hyun, Dongho, E-mail: mesentery@naver.com; Park, Kwang Bo, E-mail: kbjh.park@samsung.com [Sungkyunkwan University School of Medicine, Department of Radiology, Samsung Medical Center (Korea, Republic of); Lim, Seong Joo [Konyang University, Department of Radiology, College of Medicine, Konyang University Hospital (Korea, Republic of); Hwang, Jin Ho [Hallym University Sacred Heart Hospital, Department of Radiology (Korea, Republic of); Sinn, Dong Hyun [Sungkyunkwan University School of Medicine, Department of Medicine, Samsung Medical Center (Korea, Republic of)

    2016-04-15

    Portal biliopathy refers to obstruction of the bile duct by dilated peri- or para-ductal collateral channels following the main portal vein occlusion from various causes. Surgical shunt operation or endoscopic treatment has been reported. Herein, we report a case of portal biliopathy that was successfully treated by interventional portal vein recanalization.

  16. Portal vein thrombosis.

    Science.gov (United States)

    Chawla, Yogesh K; Bodh, Vijay

    2015-03-01

    Portal vein thrombosis is an important cause of portal hypertension. PVT occurs in association with cirrhosis or as a result of malignant invasion by hepatocellular carcinoma or even in the absence of associated liver disease. With the current research into its genesis, majority now have an underlying prothrombotic state detectable. Endothelial activation and stagnant portal blood flow also contribute to formation of the thrombus. Acute non-cirrhotic PVT, chronic PVT (EHPVO), and portal vein thrombosis in cirrhosis are the three main variants of portal vein thrombosis with varying etiological factors and variability in presentation and management. Procoagulant state should be actively investigated. Anticoagulation is the mainstay of therapy for acute non-cirrhotic PVT, with supporting evidence for its use in cirrhotic population as well. Chronic PVT (EHPVO) on the other hand requires the management of portal hypertension as such and with role for anticoagulation in the setting of underlying prothrombotic state, however data is awaited in those with no underlying prothrombotic states. TIPS and liver transplant may be feasible even in the setting of PVT however proper selection of candidates and type of surgery is warranted. Thrombolysis and thrombectomy have some role. TARE is a new modality for management of HCC with portal vein invasion.

  17. A chess web portal

    OpenAIRE

    Volf, Žiga

    2011-01-01

    The aim of the thesis was to develop a web portal for chess players, which is intended to be a place for quality chess joining over the Internet and chess education. This need is caused by existing social networks and websites for playing chess, which offer you a very small amount of quality chess joining and education. As a result of the work the chess portal was created. We have presented the development of the chess portal in the thesis, which has all the features the chess players are i...

  18. Comparison of the performance between portal dosimetry and a commercial two-dimensional array system on pretreatment quality assurance for volumetric-modulated arc and intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Kim, Yon-Lae; Chung, Jin-Beom; Kim, Jae-Sung; Lee, Jeong-Woo; Choi, Kyoung-Sik

    2014-01-01

    The aim of this study was to compare the dosimetric performance and to evaluate the pretreatment quality assurance (QA) of a portal dosimetry and a commercial two-dimensional (2-D) array system. In the characteristics comparison study, the measured values for the dose linearity, dose rate response, reproducibility, and field size dependence for 6-MV photon beams were analyzed for both detector systems. To perform the qualitative evaluations of the 10 IMRT and the 10 VMAT plans, we used the Gamma index for quantifying the agreement between calculations and measurements. The performance estimates for both systems show that overall, minimal differences in the dosimetric characteristics exist between the Electron portal imaging device (EPID) and 2-D array system. In the qualitative analysis for pretreatment quality assurance, the EPID and 2-D array system yield similar passing rate results for the majority of clinical Intensity-modulated radiation therapy (IMRT) and Volumetric-modulated arc therapy (VMAT) cases. These results were satisfactory for IMRT and VMAT fields and were within the acceptable criteria of γ % ≤1, γ avg < 0.5. The EPDI and the 2-D array systems showed comparable dosimetric results. In this study, the results revealed both systems to be suitable for patient-specific QA measurements for IMRT and VMAT. We conclude that, depending on the status of clinic, both systems can be used interchangeably for routine pretreatment QA.

  19. Comparison of the performance between portal dosimetry and a commercial two-dimensional array system on pretreatment quality assurance for volumetric-modulated arc and intensity-modulated radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yon-Lae [Choonhae College of Health Sciences, Ulsan (Korea, Republic of); The Catholic University of Korea, Seoul (Korea, Republic of); Chung, Jin-Beom; Kim, Jae-Sung [Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); Lee, Jeong-Woo [Konkuk University Medical Center, Seoul (Korea, Republic of); Choi, Kyoung-Sik [SAM Anyang Hospital, Anyang (Korea, Republic of)

    2014-04-15

    The aim of this study was to compare the dosimetric performance and to evaluate the pretreatment quality assurance (QA) of a portal dosimetry and a commercial two-dimensional (2-D) array system. In the characteristics comparison study, the measured values for the dose linearity, dose rate response, reproducibility, and field size dependence for 6-MV photon beams were analyzed for both detector systems. To perform the qualitative evaluations of the 10 IMRT and the 10 VMAT plans, we used the Gamma index for quantifying the agreement between calculations and measurements. The performance estimates for both systems show that overall, minimal differences in the dosimetric characteristics exist between the Electron portal imaging device (EPID) and 2-D array system. In the qualitative analysis for pretreatment quality assurance, the EPID and 2-D array system yield similar passing rate results for the majority of clinical Intensity-modulated radiation therapy (IMRT) and Volumetric-modulated arc therapy (VMAT) cases. These results were satisfactory for IMRT and VMAT fields and were within the acceptable criteria of γ{sub %}≤1, γ{sub avg} < 0.5. The EPDI and the 2-D array systems showed comparable dosimetric results. In this study, the results revealed both systems to be suitable for patient-specific QA measurements for IMRT and VMAT. We conclude that, depending on the status of clinic, both systems can be used interchangeably for routine pretreatment QA.

  20. ERNIE performance with TSA portals Initial Results

    Energy Technology Data Exchange (ETDEWEB)

    Labov, S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2018-01-05

    This project extends the “Enhanced Radiological Nuclear Inspection and Evaluation” (ERNIE) system developed with CBP and DNDO to improve performance of PVT-based Radiation Portal Monitors (RPMs). ERNIE was designed to be used with any RPM system. The first implementation was with the SAIC (Leidos) RPM-8 systems. In this project, we are demonstrating how effective the ERNIE approach can be when applied to the VM250 TSA portals used in NSDD programs. Part of the challenge in adapting ERNIE to handle VM250 portals is the lack of gamma spectral information. We report here on the first results showing how the ERNIE analysis can improve analysis of measurements with the VM250 RPMs.

  1. Portal monitor evaluation and test procedure

    International Nuclear Information System (INIS)

    Johnson, L.O.; Gupta, V.P.; Stevenson, R.L.; Rich, B.L.

    1983-10-01

    The purpose was to develop techniques and procedures to allow users to measure performance and sensitivity of portal monitors. Additionally, a methodology was developed to assist users in optimizing monitor performance. The two monitors tested utilized thin-window gas-flow proportional counters sensitive to beta and gamma radiation. Various tests were performed: a) background count rate and the statistical variability, b) detector efficiency at different distances, c) moving source sensitivity for various size sources and speeds, and d) false alarm rates at different background levels. A model was developed for the moving source measurements to compare the experimental data with measured results, and to test whether it is possible to adequately model the behavior of a portal monitor's response to a moving source. The model results were compared with the actual test results. A procedure for testing portal monitors is also given. 1 reference, 9 figures, 8 tables

  2. ASKME Enterprise Portal (internal) -

    Data.gov (United States)

    Department of Transportation — The ASKME Enterprise Portal Internal (AEPi) is envisioned to be an integrated, single-point-of-entry solution that contains modular components. The AEPi will provide...

  3. Quantitative vs. subjective portal verification using digital portal images

    International Nuclear Information System (INIS)

    Bissett, Randy; Leszczynski, Konrad; Loose, Stephen; Boyko, Susan; Dunscombe, Peter

    1996-01-01

    Purpose: Off-line, computer-aided prescription (simulator) and treatment (portal) image registration using chamfer matching has been implemented on PC based viewing station. The purposes of this study were (a) to evaluate the performance of interactive anatomy and field edge extraction and subsequent registration, and (b) to compare observer's perceptions of field accuracy with measured discrepancies following anatomical registration. Methods and Materials: Prescription-treatment image pairs for 48 different patients were examined in this study. Digital prescription images were produced with the aid of a television camera and a digital frame grabber, while the treatment images were obtained directly from an on-line portal imaging system. To facilitate perception of low contrast anatomical detail, on-line portal images were enhanced with selective adaptive histogram equalization prior to extraction of anatomical edges. Following interactive extraction of anatomical and field border information by an experienced observer, the identified anatomy was registered using chamber matching. The degree of conformity between the prescription and treatment fields was quantified using several parameters, which included relative prescription field coverage and overcoverage, as well as the translational and rotational displacements as measured by chamfer matching applied to the boundaries of the two fields. These quantitative measures were compared with subjective evaluations made by four radiation oncologists. Results: All the images in this series that included a range of the most commonly seen treatment sites were registered and the conformity parameters were found. The mean treatment/prescription field coverage and overcoverage were approximately 95 and 7%, respectively before registration. The mean translational displacement in the transverse and cranio-caudal directions were 2.9 and 3.4 mm, respectively. The mean rotational displacement was approximately 2 deg. . For all

  4. Liferay Portal Systems Development

    CERN Document Server

    Yuan, Jonas X

    2012-01-01

    This book focuses on teaching by example. Every chapter provides an overview, and then dives right into hands-on examples so you can see and play with the solution in your own environment. This book is for Java developers who don't need any prior experience with Liferay portal. Although Liferay portal makes heavy use of open source frameworks, no prior experience of using these is assumed.

  5. ELECTRONIC COMMERCE PORTAL

    OpenAIRE

    Georgeta Soava

    2011-01-01

    Today companies are faced with the need to exploit technology changing computer environments, in order to improve customer satisfaction and reduce costs. A successful approach to electronic portals is an effective demonstration of the new ways of relating to the client. The objectives that we have considered for the realization of e-commerce portal can be summarized as follows: structured communication, effective collaboration, complet and closed circuit of orders and deliveries, inventory op...

  6. Biology of portal hypertension.

    Science.gov (United States)

    McConnell, Matthew; Iwakiri, Yasuko

    2018-02-01

    Portal hypertension develops as a result of increased intrahepatic vascular resistance often caused by chronic liver disease that leads to structural distortion by fibrosis, microvascular thrombosis, dysfunction of liver sinusoidal endothelial cells (LSECs), and hepatic stellate cell (HSC) activation. While the basic mechanisms of LSEC and HSC dysregulation have been extensively studied, the role of microvascular thrombosis and platelet function in the pathogenesis of portal hypertension remains to be clearly characterized. As a secondary event, portal hypertension results in splanchnic and systemic arterial vasodilation, leading to the development of a hyperdynamic circulatory syndrome and subsequently to clinically devastating complications including gastroesophageal varices and variceal hemorrhage, hepatic encephalopathy from the formation of portosystemic shunts, ascites, and renal failure due to the hepatorenal syndrome. This review article discusses: (1) mechanisms of sinusoidal portal hypertension, focusing on HSC and LSEC biology, pathological angiogenesis, and the role of microvascular thrombosis and platelets, (2) the mesenteric vasculature in portal hypertension, and (3) future directions for vascular biology research in portal hypertension.

  7. Extrahepatic portal hypertension in childhood

    International Nuclear Information System (INIS)

    Takehara, Hiroo; Komi, Nobuhiko; Goh, Masahiro; Yoshida, Sadahiro; Kameoka, Kazuhiro; Hino, Masao; Sui, Osamu

    1986-01-01

    Four pediatric patients with extrahepatic portal hypertension had undergone portography and computerized radionuclide angiography in order to examine shape of portal system and to evaluate hepatic blood flow before and aftersurgical treatment. In all patients, cavernous transformation of portal system was demonstrated by portography, and in one of them spontaneous splenorenal shunt occurred. In 3 of them, who underwent esophageal transsection combined with paraesophagogastric devascularization and splenectomy, so-called direct operation, increase of portal blood flow was revealed by computerized radionuclide angiography. It is suggested that direct operation increasing portal blood flow after surgery is effective in treating extrahepatic portal hypertension in childhood. (author)

  8. Portal venous stent placement for treatment of portal hypertension caused by benign main portal vein stenosis.

    Science.gov (United States)

    Shan, Hong; Xiao, Xiang-Sheng; Huang, Ming-Sheng; Ouyang, Qiang; Jiang, Zai-Bo

    2005-06-07

    To evaluate the value of endovascular stent in the treatment of portal hypertension caused by benign main portal vein stenosis. Portal vein stents were implanted in six patients with benign main portal vein stenosis (inflammatory stenosis in three cases, postprocedure of liver transplantation in another three cases). Changes in portal vein pressure, portal vein patency, relative clinical symptoms, complications, and survival were evaluated. Six metallic stents were successfully placed across the portal vein stenotic or obstructive lesions in six patients. Mean portal venous pressure decreased significantly after stent implantation from (37.3+/-4.7) cm H(2)O to (18.0+/-1.9) cm H(2)O. The portal blood flow restored and the symptoms caused by portal hypertension were eliminated. There were no severe procedure-related complications. The patients were followed up for 1-48 mo. The portal vein remained patent during follow-up. All patients survived except for one patient who died of other complications of liver transplantation. Percutaneous portal vein stent placement for the treatment of portal hypertension caused by benign main portal vein stenosis is safe and effective.

  9. Pregnancy with Portal Hypertension

    Science.gov (United States)

    Aggarwal, Neelam; Negi, Neha; Aggarwal, Aakash; Bodh, Vijay; Dhiman, Radha K.

    2014-01-01

    Even though pregnancy is rare with cirrhosis and advanced liver disease, but it may co-exist in the setting of non-cirrhotic portal hypertension as liver function is preserved but whenever encountered together is a complex clinical dilemma. Pregnancy in a patient with portal hypertension presents a special challenge to the obstetrician as so-called physiological hemodynamic changes associated with pregnancy, needed for meeting demands of the growing fetus, worsen the portal hypertension thereby putting mother at risk of potentially life-threatening complications like variceal hemorrhage. Risks of variceal bleed and hepatic decompensation increase many fold during pregnancy. Optimal management revolves round managing the portal hypertension and its complications. Thus management of such cases requires multi-speciality approach involving obstetricians experienced in dealing with high risk cases, hepatologists, anesthetists and neonatologists. With advancement in medical field, pregnancy is not contra-indicated in these women, as was previously believed. This article focuses on the different aspects of pregnancy with portal hypertension with special emphasis on specific cause wise treatment options to decrease the variceal bleed and hepatic decompensation. Based on extensive review of literature, management from pre-conceptional period to postpartum is outlined in order to have optimal maternal and perinatal outcomes. PMID:25755552

  10. The NOAO NVO Portal

    Science.gov (United States)

    Miller, C. J.; Gasson, D.; Fuentes, E.

    2007-10-01

    The NOAO NVO Portal is a web application for one-stop discovery, analysis, and access to VO-compliant imaging data and services. The current release allows for GUI-based discovery of nearly a half million images from archives such as the NOAO Science Archive, the Hubble Space Telescope WFPC2 and ACS instruments, XMM-Newton, Chandra, and ESO's INT Wide-Field Survey, among others. The NOAO Portal allows users to view image metadata, footprint wire-frames, FITS image previews, and provides one-click access to science quality imaging data throughout the entire sky via the Firefox web browser (i.e., no applet or code to download). Users can stage images from multiple archives at the NOAO NVO Portal for quick and easy bulk downloads. The NOAO NVO Portal also provides simplified and direct access to VO analysis services, such as the WESIX catalog generation service. We highlight the features of the NOAO NVO Portal (http://nvo.noao.edu).

  11. Radioisotopic flow scanning for portal blood flow and portal hypertension

    International Nuclear Information System (INIS)

    Hesdorffer, C.S.; Bezwoda, W.R.; Danilewitz, M.D.; Esser, J.D.; Tobias, M.

    1987-01-01

    The use of a simple, noninvasive, isotope scanning technique for the determination of relative portal blood flow and detection of portal hypertension is described. Using this technique the presence of portal hypertension was demonstrated in seven of nine patients known to have elevated portal venous pressure. By contrast, esophageal varices were demonstrated in only five of these patients, illustrating the potential value of the method. Furthermore, this technique has been adapted to the study of portal blood flow in patients with myeloproliferative disorders with splenomegaly but without disturbances in hepatic architecture. Results demonstrate that the high relative splenic flow resulting from the presence of splenomegaly may in turn be associated with elevated relative portal blood flow and portal hypertension. The theoretic reasons for the development of flow-related portal hypertension and its relationship to splenic blood flow are discussed

  12. A comparison of field-only electronic portal imaging hard copies with double exposure port films in radiation therapy treatment setup confirmation to determine its clinical application in a radiotherapy center

    International Nuclear Information System (INIS)

    Hatherly, Kay; Smylie, Josephine; Rodger, Alan

    1999-01-01

    Purpose: To determine in which treatment sites field-only hard copy electronic portal images (EPI) captured during a treatment exposure could replace traditional double exposed port films in a busy radiation oncology department. Methods and Materials: The three linear accelerators in the William Buckland Radiotherapy Centre (WBRC) at the Alfred Hospital in Melbourne are each equipped with an electronic portal imaging device (EPID). These devices can be used daily on all patients where the treatment fields are within the size constraint of the cassette, for example, less than 25 x 25 cm. Port films using radiographic film in hard cassettes were previously considered the standard method of field placement verification. After the radiation therapists were trained in all program aspects of capturing, enhancing, and producing hard copies of EPIs, a study was developed to evaluate the possibility of replacing port films with EPI hard copies within the established departmental procedures. Comparison of EPI hard copy with the simulator film and the port film of the same field was carried out by the radiation oncologist specialists. Seventy-eight comparison sets were generated and grouped into seven anatomical regions for evaluation by the radiation oncologist specialist responsible for each particular region. The outcome decision was the preferred imaging option. Where no preference was stated, EPI became the modality of choice, as it increased the efficiency of work practice. Results: The results indicate that field-only EPI can be considered to be at least as clinically useful for treatment verification in the following sites: breast, chest, hip, spine, and large pelvic fields. Port films using a standard, double exposure technique were considered necessary for partial brain fields, small pelvis fields, extremities, and radical head and neck fields. Conclusion: The quality of field-only images captured using an EPID has been favorably assessed to be equivalent to, or an

  13. Personalization Methods for Internet Portals

    OpenAIRE

    Barbara Dębska; Agnieszka Kubacka

    2012-01-01

    The article presents methods of acquiring and gathering data about users of internet portals, with particular emphasis on educational portals. Definitions, aims and tasks related to the process of personalization of e-learning portals are thoroughly discussed. So are knowledge acquisition techniques applied in personalization, especially artificial intelligence methods.

  14. Distribution of Functional Liver Volume in Hepatocellular Carcinoma Patients with Portal Vein Tumor Thrombus in the 1st Branch and Main Trunk Using Single Photon Emission Computed Tomography—Application to Radiation Therapy

    Directory of Open Access Journals (Sweden)

    Akira Ikoma

    2011-10-01

    Full Text Available Purpose: To analyze the distribution of functional liver volume (FLV in the margin volume (MV surrounding hepatocellular carcinoma (HCC with portal vein tumor thrombus (PVTT before radiation therapy (RT and to verify the safety of single photon emission computed tomography-based three-dimensional conformal radiotherapy (SPECT-B3DCRT by exploring the relation of FLV in MV to radiation-induced liver disease (RILD. Methods and Materials: Clinical target volume (CTV included main tumor and PVTT, and planning target volume (PTV included CTV with a 10 mm margin. MV was defined as PTV–CTV. FLV ratio in MV was calculated as FLV in MV/MV × 100 (%. The two high-dose beams were planned to irradiate FLV as little as possible. Fifty-seven cases of HCC (26/57, 46%; Child–Pugh grade B with PVTT underwent SPECT-B3DCRT which targeted the CTV to a total dose of 45 Gy/18 fractions. The destructive ratio was defined as radiation induced dysfunctional volume/FLV × 100 (%. Results: We observed a significant negative correlation between FLV ratio in MV and CTV (p < 0.001. Three cases with CTVs of 287, 587 and 1184 cm3 experienced transient RILD. The FLV ratio in MV was highest in patients with RILD: nine patients with CTV of 200–300 cm3, three with CTV of 500–600 cm3, and two with CTV of 1100–1200 cm3. The destructive ratio yielded a mean value of 24.2 ± 1.5%. Conclusions: Radiation planning that takes into account the distribution of FLV appears to result in the least possible RILD.

  15. The Learning Portal

    Science.gov (United States)

    Staudt, Carolyn; Hanzlick-Burton, Camden; Williamson, Carol; McIntyre, Cynthia

    2015-01-01

    The Innovative Technology in Science Inquiry (ITSI) project is a learning portal with hundreds of free, customizable science, math, and engineering activities funded by the National Science Foundation at the Concord Consortium, a nonprofit research and development organization dedicated to transforming education through technology. The project…

  16. BRAZILIAN NEWS PORTALS CHARACTERISTICS

    Directory of Open Access Journals (Sweden)

    Heloiza G. Herckovitz

    2011-02-01

    Full Text Available A content analysis of four Brazilian news media portals found that economic news dominated the top headlines with little attention paid to education, the environment and welfare. Other trends included a focus on local events and national news sources, reliance on few sources, mostly official ones, and a low percentage of news that fitted the concept of newsworthiness (a combination of both social significance and deviance concepts. Other findings of a study of 432 top news stories published by UOL, Estadão, iG and Terra during a 15-day period between February and March 2008 indicate that the top portions of the portals’ front pages carry news that lacks story depth, editorial branding, and multimedia applications. The results suggest that online news portals are in their infancy although Brazil has the largest online population of Latin America. This study hopes to shed light on the gatekeeping process in Brazilian news portals. Brazilian media portals have yet to become a significant editorial force able to provide knowledge about social issues and public affairs in a socially responsible fashione.

  17. An automated portal verification system for the tangential breast portal field

    International Nuclear Information System (INIS)

    Yin, F.-F.; Lai, W.; Chen, C. W.; Nelson, D. F.

    1995-01-01

    Purpose/Objective: In order to ensure the treatment is delivered as planned, a portal image is acquired in the accelerator and is compared to the reference image. At present, this comparison is performed by radiation oncologists based on the manually-identified features, which is both time-consuming and potentially error-prone. With the introduction of various electronic portal imaging devices, real-time patient positioning correction is becoming clinically feasible to replace time-delayed analysis using films. However, this procedure requires present of radiation oncologists during patient treatment which is not cost-effective and practically not realistic. Therefore, the efficiency and quality of radiation therapy could be substantially improved if this procedure can be automated. The purpose of this study is to develop a fully computerized verification system for the radiation therapy of breast cancer for which a similar treatment setup is generally employed. Materials/Methods: The automated verification system involves image acquisition, image feature extraction, feature correlation between reference and portal images, and quantitative evaluation of patient setup. In this study, a matrix liquid ion-chamber EPID was used to acquire digital portal images which is directly attached to Varian CL2100C accelerator. For effective use of computation memory, the 12-bit gray levels in original portal images were quantized to form a range of 8-bit gray levels. A typical breast portal image includes three important components: breast and lung tissues in the treatment field, air space within the treatment field, and non-irradiated region. A hierarchical region processing technique was developed to separate these regions sequentially. The inherent hierarchical features were formulated based on different radiation attenuation for different regions as: treatment field edge -- breast skin line -- chest wall. Initially, a combination of a Canny edge detector and a constrained

  18. Angiography in portal hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Zeitler, E

    1982-04-05

    We report on the cooperative possibilities the radiologist has as to diagnosis and therapy of portal hypertension. The catheter angiography allows to make a differentiation between pre- and intrahepatic bloc and the localization of bleeding esophagus varices. Only after all endoscopic measures with sclerotherapy and Laser coagulation have failed, catheter angiography will be carried out as a therapeutic measure. The future development, however, will give the opportunity to a series of therapeutic attempts on the field of interventional radiology.

  19. Angiography in portal hypertension

    International Nuclear Information System (INIS)

    Zeitler, E.

    1982-01-01

    We report on the cooperative possibilities the radiologist has as to diagnosis and therapy of portal hypertension. The catheter angiography allows to make a differentiation between pre- and intrahepatic bloc and the localization of bleeding esophagus varices. Only after all endoscopic measures with sclerotherapy and Laser coagulation have failed, catheter angiography will be carried out as a therapeutic measure. The future development, however, will give the opportunity to a series of therapeutic attempts on the field of interventional radiology. (orig.) [de

  20. Portal Annular Pancreas

    Science.gov (United States)

    Harnoss, Jonathan M.; Harnoss, Julian C.; Diener, Markus K.; Contin, Pietro; Ulrich, Alexis B.; Büchler, Markus W.; Schmitz-Winnenthal, Friedrich H.

    2014-01-01

    Abstract Portal annular pancreas (PAP) is an asymptomatic congenital pancreas anomaly, in which portal and/or mesenteric veins are encased by pancreas tissue. The aim of the study was to determine the role of PAP in pancreatic surgery as well as its management and potential complication, specifically, postoperative pancreatic fistula (POPF). On the basis of a case report, the MEDLINE and ISI Web of Science databases were systematically reviewed up to September 2012. All articles describing a case of PAP were considered. In summary, 21 studies with 59 cases were included. The overall prevalence of PAP was 2.4% and the patients' mean (SD) age was 55.9 (16.2) years. The POPF rate in patients with PAP (12 pancreaticoduodenectomies and 3 distal pancreatectomies) was 46.7% (in accordance with the definition of the International Study Group of Pancreatic Surgery). Portal annular pancreas is a quite unattended pancreatic variant with high prevalence and therefore still remains a clinical challenge to avoid postoperative complications. To decrease the risk for POPF, attentive preoperative diagnostics should also focus on PAP. In pancreaticoduodenectomy, a shift of the resection plane to the pancreas tail should be considered; in extensive pancreatectomy, coverage of the pancreatic remnant by the falciform ligament could be a treatment option. PMID:25207658

  1. Obliterative portal venopathy without portal hypertension: an underestimated condition.

    Science.gov (United States)

    Guido, Maria; Sarcognato, Samantha; Sonzogni, Aurelio; Lucà, Maria Grazia; Senzolo, Marco; Fagiuoli, Stefano; Ferrarese, Alberto; Pizzi, Marco; Giacomelli, Luciano; Colloredo, Guido

    2016-03-01

    Obliterative portal venopathy without portal hypertension has been described by a single study in a limited number of patients, thus very little is known about this clinical condition. This study aimed to investigate the prevalence of obliterative portal venopathy and its clinical-pathological correlations in patients with cryptogenic chronic liver test abnormalities without clinical signs of portal hypertension. We analysed 482 liver biopsies from adults with non-cirrhotic cryptogenic chronic liver disorders and without any clinical signs of portal hypertension, consecutively enrolled in a 5-year period. Twenty cases of idiopathic non-cirrhotic portal hypertension diagnosed in the same period, were included for comparison. Histological findings were matched with clinical and laboratory features. Obliterative portal venopathy was identified in 94 (19.5%) of 482 subjects and in all 20 cases of idiopathic non-cirrhotic portal hypertension: both groups shared the entire spectrum of histological changes described in the latter condition. The prevalence of incomplete fibrous septa and nodular regenerative hyperplasia was higher in the biopsies of idiopathic non-cirrhotic portal hypertension (P = 0.006 and P = 0.002), a possible hint of a more advanced stage of the disease. The two groups also shared several clinical laboratory features, including a similar liver function test profile, concomitant prothrombotic conditions and extrahepatic autoimmune disorders. Obliterative portal venopathy occurs in a substantial proportion of patients with unexplained chronic abnormal liver function tests without portal hypertension. The clinical-pathological profile of these subjects suggests that they may be in an early (non-symptomatic) stage of idiopathic non-cirrhotic portal hypertension. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Portal hemodynamics in chronic portal-systemic encephalopathy

    International Nuclear Information System (INIS)

    Takashi, Motohide; Igarashi, Masahiko; Hino, Shinichi; Takayasu, Kenichi; Goto, Nobuaki; Musha, Hirotaka; Ohnishi, Kunihiko; Okuda, Kunio

    1985-01-01

    A portal hemodynamic study was made in 7 consecutive patients with chronic portal-systemic encephalopathy by percutaneous transhepatic catheterization of the portal vein and injecting contrast medium into the superior mesenteric vein or by superior mesenteric arterial portography in comparison with patients without encephalopathy studied by percutaneous catheterization of these veins. It is suggested that chronic portal-systemic encephalopathy is a result of a large collateral route shunting a large proportion of the superior mesenteric venous blood into systemic circulation, and that development of such collaterals precludes formation of large esophageal varices. (Auth.)

  3. MR image-guided portal verification for brain treatment field

    International Nuclear Information System (INIS)

    Yin, F.-F.; Gao, Q.H.; Xie, H.; Nelson, D.F.; Yu, Y.; Kwok, W.E.; Totterman, S.; Schell, M.C.; Rubin, P.

    1996-01-01

    Purpose/Objective: Although MR images have been extensively used for the treatment planning of radiation therapy of cancers, especially for brain cancers, they are not effectively used for the portal verification due to lack of bone/air information in MR images and geometric distortions. Typically, MR images are utilized through correlation with CT images, and this procedure is usually very labor and time consuming. For many brain cancer patients to be treated using conventional external beam radiation, MR images with proper distortion correction provide sufficient information for treatment planning and dose calculation, and a projection images may be generated for each specific treatment port and to be used as a reference image for treatment verification. The question is how to transfer anatomical features in MR images to the projection image as landmarks which could be correlated automatically to those in the portal image. The goal of this study is to generate digitally reconstructed projection images from MR brain images with some important anatomical features (brain contour, skull and gross tumor) as well as their relative locations to be used as references for the development of computerized portal verification scheme. Materials/Methods: Compared to conventional digital reconstructed radiograph from CT images, generation of digitally reconstructed projection images from MR images is heavily involved with pixel manipulation of MR images to correlate information from two types of images (MR, portal x-ray images) which are produced based on totally different imaging principles. Initially a wavelet based multi-resolution adaptive thresholding method is used to segment the skull slice-by-slice in MR brain axial images, and identified skull pixels are re-assigned to relatively higher intensities so that projection images will have comparable grey-level information as that in typical brain portal images. Both T1- and T2-weighted images are utilized to eliminate fat

  4. Knowledge Portals: Ontologies at Work

    OpenAIRE

    Staab, Steffen; Maedche, Alexander

    2001-01-01

    Knowledge portals provide views onto domain-specific information on the World Wide Web, thus helping their users find relevant, domain-specific information. The construction of intelligent access and the contribution of information to knowledge portals, however, remained an ad hoc task, requiring extensive manual editing and maintenance by the knowledge portal providers. To diminish these efforts, we use ontologies as a conceptual backbone for providing, accessing, and structuring information...

  5. Tolerance of canine portal vein anastomosis to intraoperative X-irradiation

    International Nuclear Information System (INIS)

    Ohara, K.; Takeshima, T.

    1987-01-01

    Tolerance of surgical portal vein anatomosis to intraoperative radiation therapy (IORT) was studied in dogs after single doses of zero, 10, 20 and 40 Gy (290 kVp X-rays). Portal venography was performed prior to IORT and before sacrificing. The dogs were sacrificed 3 and 12 months respectively after irradiation. Portal venography revealed no radiation induced anastomotic stenosis. Autopys disclosed macroscopic periportal fibrosis in all dogs, independent of radiation dose and observation periods. Microscopically, the three tunicas of the vein did not show any pathological changes after any dose level. (orig.)

  6. Duplex sonography in portal hypertension

    International Nuclear Information System (INIS)

    Kwon, Hyuk Po; Jang, J. C.; Park, B. H.

    1990-01-01

    We measure the diameter and blood velocity of the portal vein in 50 patients with cirrhosis of the liver and 40 healthy subjects, and calculated cross sectional area, mean blood flow velocity, blood flow volume and congestion index. In patients with cirrhosis of the liver, the cross sectional area of the portal vein was significantly increased: the mean blood flow volume was significantly reduced; the blood flow volume was significantly increased; the congestion index of the portal vein was significantly increased. Duples sonography may play an important role in the diagnosis of portal hypertension

  7. A review of portal screen-film technology and five radiologists' evaluations of some existing products.

    Science.gov (United States)

    Walker, M A; Steinheimer, D N; Weir, V A; Homco, L D; Green, R W; Morris, E L; Hess, M E

    1999-01-01

    Portal radiographs, radiographs made to document the accuracy of radiotherapy treatment fields, are typically of poor image contrast. Recently, a new portal film and screened-cassette system was marketed, the Kodak EC-L system, with the claim of greatly improved image contrast. This new EC-L system was tested on a canine cadaver exposed to Cobalt-60 teletherapy gamma radiation, and image quality was compared to earlier marketed Kodak portal film products. The EC-L system was found to provide portal images of improved contrast/quality.

  8. The Protein Model Portal.

    Science.gov (United States)

    Arnold, Konstantin; Kiefer, Florian; Kopp, Jürgen; Battey, James N D; Podvinec, Michael; Westbrook, John D; Berman, Helen M; Bordoli, Lorenza; Schwede, Torsten

    2009-03-01

    Structural Genomics has been successful in determining the structures of many unique proteins in a high throughput manner. Still, the number of known protein sequences is much larger than the number of experimentally solved protein structures. Homology (or comparative) modeling methods make use of experimental protein structures to build models for evolutionary related proteins. Thereby, experimental structure determination efforts and homology modeling complement each other in the exploration of the protein structure space. One of the challenges in using model information effectively has been to access all models available for a specific protein in heterogeneous formats at different sites using various incompatible accession code systems. Often, structure models for hundreds of proteins can be derived from a given experimentally determined structure, using a variety of established methods. This has been done by all of the PSI centers, and by various independent modeling groups. The goal of the Protein Model Portal (PMP) is to provide a single portal which gives access to the various models that can be leveraged from PSI targets and other experimental protein structures. A single interface allows all existing pre-computed models across these various sites to be queried simultaneously, and provides links to interactive services for template selection, target-template alignment, model building, and quality assessment. The current release of the portal consists of 7.6 million model structures provided by different partner resources (CSMP, JCSG, MCSG, NESG, NYSGXRC, JCMM, ModBase, SWISS-MODEL Repository). The PMP is available at http://www.proteinmodelportal.org and from the PSI Structural Genomics Knowledgebase.

  9. CT portal venography manifestations of portal collateral circulation in patients with portal hypertension due to cirrhosis

    International Nuclear Information System (INIS)

    Ni Ming; Lv Weifu; Deng Kexue

    2009-01-01

    Objective: To analyze CT portal venography (CTPV) manifestations of portal collateral circulation in patients with cirrhosis by using a 16-detector row spiral CT scanner. Methods: CTPV was performed in 36 patients with portal hypertension due to cirrhosis, the diagnosis was proved by clinical data, hepatic function findings and imaging signs. By using post-processing reconstruction technique, 3D images of portal venous system and portal collateral circulation were obtained. Results: CTPV images displayed the portal venous system and its collateral circulation stereoscopically. Of 36 patients, left gastric varices were seen in 29(80.6%), lower esophageal varices in 18(50.0%), short gastric or posterior gastric varices in 15(41.7%), paraesophageal varices in 9(25.0%), gastro-renal or splenorenal shunts in 8(22.2%), spongelike transformation of portal vein in 7(19.4%), paraumbilical and abdominal wall varices in 6(16.7%), congenital cavernous in 6(16.7%) and paravertebral venous shunts in 4(11.1%). Conclusion: CTPV can well display the site, extent and severity of the portal collateral circulation in patients with portal hypertension due to cirrhosis,which is of great clinical importance for judging the patient's condition, for selecting therapeutic protocols and for estimating prognosis. (authors)

  10. Algorithms for contrast enhancement of electronic portal images

    International Nuclear Information System (INIS)

    Díez, S.; Sánchez, S.

    2015-01-01

    An implementation of two new automatized image processing algorithms for contrast enhancement of portal images is presented as suitable tools which facilitate the setup verification and visualization of patients during radiotherapy treatments. In the first algorithm, called Automatic Segmentation and Histogram Stretching (ASHS), the portal image is automatically segmented in two sub-images delimited by the conformed treatment beam: one image consisting of the imaged patient obtained directly from the radiation treatment field, and the second one is composed of the imaged patient outside it. By segmenting the original image, a histogram stretching can be independently performed and improved in both regions. The second algorithm involves a two-step process. In the first step, a Normalization to Local Mean (NLM), an inverse restoration filter is applied by dividing pixel by pixel a portal image by its blurred version. In the second step, named Lineally Combined Local Histogram Equalization (LCLHE), the contrast of the original image is strongly improved by a Local Contrast Enhancement (LCE) algorithm, revealing the anatomical structures of patients. The output image is lineally combined with a portal image of the patient. Finally the output images of the previous algorithms (NLM and LCLHE) are lineally combined, once again, in order to obtain a contrast enhanced image. These two algorithms have been tested on several portal images with great results. - Highlights: • Two Algorithms are implemented to improve the contrast of Electronic Portal Images. • The multi-leaf and conformed beam are automatically segmented into Portal Images. • Hidden anatomical and bony structures in portal images are revealed. • The task related to the patient setup verification is facilitated by the contrast enhancement then achieved.

  11. Lunar and Vesta Web Portals

    Science.gov (United States)

    Law, E.; JPL Luna Mapping; Modeling Project Team

    2015-06-01

    The Lunar Mapping and Modeling Project offers Lunar Mapping and Modeling Portal (http://lmmp.nasa.gov) and Vesta Trek Portal (http://vestatrek.jpl.nasa.gov) providing interactive visualization and analysis tools to enable users to access mapped Lunar and Vesta data products.

  12. Portal dosimetry in wedged beams

    NARCIS (Netherlands)

    Spreeuw, Hanno; Rozendaal, Roel; Camargo, Priscilla; Mans, Anton; Wendling, Markus; Olaciregui-Ruiz, Igor; Sonke, Jan-Jakob; van Herk, Marcel; Mijnheer, Ben

    2015-01-01

    Portal dosimetry using electronic portal imaging devices (EPIDs) is often applied to verify high-energy photon beam treatments. Due to the change in photon energy spectrum, the resulting dose values are, however, not very accurate in the case of wedged beams if the pixel-to-dose conversion for the

  13. WLCG Operations portal demo tutorial

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    This is a navigation through http://wlcg-ops.web.cern.ch/ the Worldwide LHC Computing Grid (WLCG) Operations' portal. In this portal you will find documentation and information about WLCG Operation activities for: System Administrators at the WLCG sites LHC Experiments Operation coordination people, including Task Forces and Working Groups

  14. Health literacy and patient portals.

    Science.gov (United States)

    Gu, Yulong; Orr, Martin; Warren, Jim

    2015-06-01

    Health literacy has been described as the capacity to obtain, process, and understand basic health information and services needed to make appropriate health decisions. Improving health literacy may serve to promote concordance with therapy, engage patients in their own health care, and improve health outcomes. Patient portal technology aims at enabling patients and families to have easy access to key information in their own medical records and to communicate with their health care providers electronically. However, there is a gap in our understanding of how portals will improve patient outcome. The authors believe patient portal technology presents an opportunity to improve patient concordance with prescribed therapy, if adequate support is provided to equip patients (and family/carers) with the knowledge needed to utilise the health information available via the portals. Research is needed to understand what a health consumer will use patient portals for and how to support a user to realise the technology's potential.

  15. Portal monitoring technology control process

    International Nuclear Information System (INIS)

    York, R.L.

    1998-01-01

    Portal monitors are an important part of the material protection, control, and accounting (MPC and A) programs in Russia and the US. Although portal monitors are only a part of an integrated MPC and A system, they are an effective means of controlling the unauthorized movement of special nuclear material (SNM). Russian technical experts have gained experience in the use of SNM portal monitors from US experts ad this has allowed them to use the monitors more effectively. Several Russian institutes and companies are designing and manufacturing SNM portal monitors in Russia. Interactions between Russian and US experts have resulted in improvements to the instruments. SNM portal monitor technology has been effectively transferred from the US to Russia and should be a permanent part of the Russian MPC and A Program. Progress in the implementation of the monitors and improvements to how they are used are discussed

  16. Software tool for portal dosimetry research.

    Science.gov (United States)

    Vial, P; Hunt, P; Greer, P B; Oliver, L; Baldock, C

    2008-09-01

    This paper describes a software tool developed for research into the use of an electronic portal imaging device (EPID) to verify dose for intensity modulated radiation therapy (IMRT) beams. A portal dose image prediction (PDIP) model that predicts the EPID response to IMRT beams has been implemented into a commercially available treatment planning system (TPS). The software tool described in this work was developed to modify the TPS PDIP model by incorporating correction factors into the predicted EPID image to account for the difference in EPID response to open beam radiation and multileaf collimator (MLC) transmitted radiation. The processes performed by the software tool include; i) read the MLC file and the PDIP from the TPS, ii) calculate the fraction of beam-on time that each point in the IMRT beam is shielded by MLC leaves, iii) interpolate correction factors from look-up tables, iv) create a corrected PDIP image from the product of the original PDIP and the correction factors and write the corrected image to file, v) display, analyse, and export various image datasets. The software tool was developed using the Microsoft Visual Studio.NET framework with the C# compiler. The operation of the software tool was validated. This software provided useful tools for EPID dosimetry research, and it is being utilised and further developed in ongoing EPID dosimetry and IMRT dosimetry projects.

  17. The Portuguese Climate Portal

    Science.gov (United States)

    Gomes, Sandra; Deus, Ricardo; Nogueira, Miguel; Viterbo, Pedro; Miranda, Miguel; Antunes, Sílvia; Silva, Alvaro; Miranda, Pedro

    2016-04-01

    The Portuguese Local Warming Website (http://portaldoclima.pt) has been developed in order to support the society in Portugal in preparing for the adaptation to the ongoing and future effects of climate change. The climate portal provides systematic and easy access to authoritative scientific data ready to be used by a vast and diverse user community from different public and private sectors, key players and decision makers, but also to high school students, contributing to the increase in knowledge and awareness on climate change topics. A comprehensive set of regional climate variables and indicators are computed, explained and graphically presented. Variables and indicators were built in agreement with identified needs after consultation of the relevant social partners from different sectors, including agriculture, water resources, health, environment and energy and also in direct cooperation with the Portuguese National Strategy for Climate Change Adaptation (ENAAC) group. The visual interface allows the user to dynamically interact, explore, quickly analyze and compare, but also to download and import the data and graphics. The climate variables and indicators are computed from state-of-the-art regional climate model (RCM) simulations (e.g., CORDEX project), at high space-temporal detail, allowing to push the limits of the projections down to local administrative regions (NUTS3) and monthly or seasonal periods, promoting local adaptation strategies. The portal provides both historical data (observed and modelled for the 1971-2000 period) and future climate projections for different scenarios (modelled for the 2011-2100 period). A large effort was undertaken in order to quantify the impacts of the risk of extreme events, such as heavy rain and flooding, droughts, heat and cold waves, and fires. Furthermore the different climate scenarios and the ensemble of RCM models, with high temporal (daily) and spatial (~11km) detail, is taken advantage in order to

  18. Comparative Investigation of Ce3+ Doped Scintillators in a Wide Range of Photon Energies Covering X-ray CT, Nuclear Medicine and Megavoltage Radiation Therapy Portal Imaging Applications

    Science.gov (United States)

    Valais, Ioannis G.; Michail, Christos M.; David, Stratos L.; Liaparinos, Panagiotis F.; Fountos, George P.; Paschalis, Theodoros V.; Kandarakis, Ioannis S.; Panayiotakis, George S.

    2010-02-01

    The aim of the present work is to study the performance of scintillators currently used in PET and animal PET systems, under conditions met in radiation therapy and PET/CT imaging. The results of this study will be useful in applications where both CT and PET photons as well as megavoltage cone beam CT (MV CBCT) photons could be detected using a common detector unit. To this aim crystal samples of GSO, LSO, LYSO, LuYAP and YAP scintillators, doped with cerium (Ce+3) were examined under a wide energy range of photon energies. Evaluation was performed by determining the absolute luminescence efficiency (emitted light flux over incident X-ray exposure) in the energy range employed in X-ray CT, in Nuclear Medicine (70 keV up to 662 keV) and in radiotherapy 6 MV (approx. 2.0 MeV mean energy)-18 MV (approx. 4.5 MeV mean energy). Measurements were performed using an experimental set-up based on a photomultiplier coupled to a light integration sphere. The emission spectrum under X-ray excitation was measured, using an optical grating monochromator, to determine the spectral compatibility to optical photon detectors incorporated in medical imaging systems. Maximum absolute luminescence efficiency values were observed at 70 keV for YAP:Ce and LuYAP:Ce and at 140 keV for LSO:Ce, LYSO:Ce and GSO:Ce. Highest absolute efficiency between the scintillators examined was observed for LSO:Ce, followed by LYSO:Ce. The detector optical gain (DOG) exhibited a significant variation with the increase of energy between 70 keV to 2.0 MeV. All scintillators exhibited low compatibility when combined with GaAsP (G5645) photodetector.

  19. New ICPP portal monitor

    International Nuclear Information System (INIS)

    Georgeson, M.A.; Nichols, C.E.

    1981-04-01

    A large area gas filled proportional-detector portal monitor mounted in a swinging door frame has been designed and developed at the Idaho Chemical Processing Plant (ICPP). This monitor extends the sensitivity and speed of personnel contamination detection to levels equal to or exceeding that obtained using hand-held portable survey techniques. The new monitor has state-of-the-art electronics which result in rapid response, and use statistical principles in the alarm logic to reduce or eliminate spurious alarms. In addition, the evaluation of this instrument indicates that it will detect small enough quantities of U-235 in shielded containers to meet current special nuclear materials (SNM) detection standards. Simultaneous detection of very low level contamination and small quantities of SNM results in a monitor particularly useful for nuclear installations

  20. Clinical Implementation of a Model-Based In Vivo Dose Verification System for Stereotactic Body Radiation Therapy–Volumetric Modulated Arc Therapy Treatments Using the Electronic Portal Imaging Device

    Energy Technology Data Exchange (ETDEWEB)

    McCowan, Peter M., E-mail: pmccowan@cancercare.mb.ca [Medical Physics Department, CancerCare Manitoba, Winnipeg, Manitoba (Canada); Asuni, Ganiyu [Medical Physics Department, CancerCare Manitoba, Winnipeg, Manitoba (Canada); Van Uytven, Eric [Medical Physics Department, CancerCare Manitoba, Winnipeg, Manitoba (Canada); Department of Physics and Astronomy, University of Manitoba, Winnipeg, Manitoba (Canada); VanBeek, Timothy [Medical Physics Department, CancerCare Manitoba, Winnipeg, Manitoba (Canada); McCurdy, Boyd M.C. [Medical Physics Department, CancerCare Manitoba, Winnipeg, Manitoba (Canada); Department of Physics and Astronomy, University of Manitoba, Winnipeg, Manitoba (Canada); Department of Radiology, University of Manitoba, Winnipeg, Manitoba (Canada); Loewen, Shaun K. [Department of Oncology, University of Calgary, Calgary, Alberta (Canada); Ahmed, Naseer; Bashir, Bashir; Butler, James B.; Chowdhury, Amitava; Dubey, Arbind; Leylek, Ahmet; Nashed, Maged [CancerCare Manitoba, Winnipeg, Manitoba (Canada)

    2017-04-01

    Purpose: To report findings from an in vivo dosimetry program implemented for all stereotactic body radiation therapy patients over a 31-month period and discuss the value and challenges of utilizing in vivo electronic portal imaging device (EPID) dosimetry clinically. Methods and Materials: From December 2013 to July 2016, 117 stereotactic body radiation therapy–volumetric modulated arc therapy patients (100 lung, 15 spine, and 2 liver) underwent 602 EPID-based in vivo dose verification events. A developed model-based dose reconstruction algorithm calculates the 3-dimensional dose distribution to the patient by back-projecting the primary fluence measured by the EPID during treatment. The EPID frame-averaging was optimized in June 2015. For each treatment, a 3%/3-mm γ comparison between our EPID-derived dose and the Eclipse AcurosXB–predicted dose to the planning target volume (PTV) and the ≥20% isodose volume were performed. Alert levels were defined as γ pass rates <85% (lung and liver) and <80% (spine). Investigations were carried out for all fractions exceeding the alert level and were classified as follows: EPID-related, algorithmic, patient setup, anatomic change, or unknown/unidentified errors. Results: The percentages of fractions exceeding the alert levels were 22.6% for lung before frame-average optimization and 8.0% for lung, 20.0% for spine, and 10.0% for liver after frame-average optimization. Overall, mean (± standard deviation) planning target volume γ pass rates were 90.7% ± 9.2%, 87.0% ± 9.3%, and 91.2% ± 3.4% for the lung, spine, and liver patients, respectively. Conclusions: Results from the clinical implementation of our model-based in vivo dose verification method using on-treatment EPID images is reported. The method is demonstrated to be valuable for routine clinical use for verifying delivered dose as well as for detecting errors.

  1. Congestive index of portal vein

    International Nuclear Information System (INIS)

    Kim, Won Ho; Kim, H. K.; Lee, S. C.; Han, S. H.; Han, K. H.; Chung, J. B.; Choi, H. J.

    1989-01-01

    In patients with portal hypertension, the blood flow volume is maintained despite decreased blood flow velocity due to enlargement of the vascular cross sectional area. Thus, the 'congestion index' of the portal vein, which is the ratio between the cross sectional area (cm2) and the blood flow velocity (cm/sec) determined by a Doppler ultrasonography, may be a sensitive index by which to assess portal hypertension. We performed Doppler ultrasonography on 24 normal subjects, 14 patients with biopsy proved chronic active hepatitis and 55 patients with liver cirrhosis in order to assess the diagnostic value of the congestion index. The cross sectional area of the portal vein was significantly enlarged and the mean blood flow velocity was significantly reduced in patients with liver cirrhosis compared with controls. However, the blood flow volume was no difference. The congestion index of the portal vein was significantly increased in patients with liver cirrhosis (0.113+0.035) compared with patients with chronic active hepatitis(0.078+0.029) (p<0.001) and controls (0.053+0.016) (p<0.001). The sensitivity, specificity and predictability of the congestion index for detection of patients with the cirrhosis of the liver were 76.4%, 100% and 100% respectively, when the normal range was set at mean+2SD. The results suggest that the congestion index of the portal vein may pla a significant role in diagnosis of portal hypertensive patients

  2. Information Portal Costs and Benefits

    Directory of Open Access Journals (Sweden)

    Lorena BATAGAN

    2006-01-01

    Full Text Available All transformations of our society are the product of the large use of Information and Communications Technologies (ICT and Internet. ICT are technologies which facilitate communication, processing, and transmission of information by electronic means. It is very important to use the new technologies to the correct value because this determinate an increase of global benefits. Portal provides a consistent way to select, evaluate, prioritize and plan the right information. In research we point the important costs and benefits for an informational portal. The portal for local administrative determinate for citizens the access to information of interest and on the other hand make easier for employer to manage the documents.

  3. The Higgs Portal and Cosmology

    Energy Technology Data Exchange (ETDEWEB)

    Assamagan, Ketevi [Brookhaven National Lab. (BNL), Upton, NY (United States); Chen, Chien-Yi [Perimeter Inst. for Theoretical Physics, Waterloo, ON (Canada); Univ. of Victoria, BC (Canada); Chou, John Paul [Rutgers Univ., Piscataway, NJ (United States); Curtin, David [Univ. of Maryland, College Park, MD (United States); Fedderke, Michael A. [Univ. of Chicago, IL (United States); Gershtein, Yuri [Rutgers Univ., Piscataway, NJ (United States); He, Xiao-Gang [Shanghai Jiao Tong Univ. (China); Klute, Markus [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States); Kozaczuk, Jonathon [TRIUMF, Vancouver, BC (Canada); Kotwal, Ashutosh [Duke Univ., Durham, NC (United States); Lowette, Steven [Vrije Univ., Brussels (Belgium); No, Jose Miguel [Univ. of Sussex, Brighton (United Kingdom); Plehn, Tilman [Heidelberg Univ. (Germany); Qian, Jianming [Univ. of Michigan, Ann Arbor, MI (United States); Ramsey-Musolf, Michael [Univ. of Massachusetts, Amherst, MA (United States); Safonov, Alexei [Texas A & M Univ., College Station, TX (United States); Shelton, Jessie [Univ. of Illinois, Urbana-Champaign, IL (United States); Spannowsky, Michael [Durham Univ. (United Kingdom); Su, Shufang [Univ. of Arizona, Tucson, AZ (United States); Walker, Devin G. E. [Univ. of Washington, Seattle, WA (United States); Willocq, Stephane [Univ. of Massachusetts, Amherst, MA (United States); Winslow, Peter [Univ. of Massachusetts, Amherst, MA (United States)

    2016-04-18

    Higgs portal interactions provide a simple mechanism for addressing two open problems in cosmology: dark matter and the baryon asymmetry. In the latter instance, Higgs portal interactions may contain the ingredients for a strong first-order electroweak phase transition as well as new CP-violating interactions as needed for electroweak baryogenesis. These interactions may also allow for a viable dark matter candidate. We survey the opportunities for probing the Higgs portal as it relates to these questions in cosmology at the LHC and possible future colliders.

  4. Fundamental factors influencing portal image quality

    International Nuclear Information System (INIS)

    Jaffray, D.A.

    1995-01-01

    It has been recognized that improved methods of verifying radiation field placement in external beam radiotherapy are required in order to make frequent checks of field placement feasible. As a result, a large number of electronic portal imaging systems have been developed as possible replacements for film. These developments have produced digital systems with faster acquisition and improved display contrast, however, the quality of the images acquired with such systems is still disappointing. This presentation examines many of the fundamental factors which limit the quality of radiographs obtained with a megavoltage radiotherapy beam. The size and shape of the radiation sources (focal and extra-focal) in radiotherapy machines and their influence on the spatial resolution of portal images are examined. Monte Carlo simulations of x-ray interactions within the patient determined that a significant fraction of the x-ray scatter generated in the patient is due to bremsstrahlung and positron annihilation. Depending on the detector, the scatter signal can reduce the differential signal-to-noise by 20%. Furthermore, a Monte Carlo study of the interaction of x-rays within typical fluoroscopic imaging detectors (metal plate/phosphor screen) demonstrates the degrading effect of energy absorption noise on the detective quantum efficiency of fluoroscopic based imaging systems. Finally, the spatial frequency content in the x-ray shadowgram is demonstrated to change with x-ray energy, resulting in images that appear to have reduced spatial resolution at megavoltage energies. The relative magnitude of each of these factors will be presented and recommendations for the next generation of portal imaging systems will be made

  5. Quality control of portal imaging with PTW EPID QC PHANTOM registered

    International Nuclear Information System (INIS)

    Pesznyak, Csilla; Kiraly, Reka; Polgar, Istvan; Zarand, Pal; Mayer, Arpad; Fekete, Gabor; Mozes, Arpad; Kiss, Balazs

    2009-01-01

    Purpose: quality assurance (QA) and quality control (QC) of different electronic portal imaging devices (EPID) and portal images with the PTW EPID QC PHANTOM registered . Material and methods: characteristic properties of images of different file formats were measured on Siemens OptiVue500aSi registered , Siemens BeamView Plus registered , Elekta iView registered , and Varian PortalVision trademark and analyzed with the epidSoft registered 2.0 program in four radiation therapy centers. The portal images were taken with Kodak X-OMAT V registered and the Kodak Portal Localisation ReadyPack registered films and evaluated with the same program. Results: the optimal exposition both for EPIDs and portal films of different kind was determined. For double exposition, the 2+1 MU values can be recommended in the case of Siemens OptiVue500aSi registered , Elekta iView registered and Kodak Portal Localisation ReadyPack registered films, while for Siemens BeamView Plus registered , Varian PortalVision trademark and Kodak X-OMAT V registered film 7+7 MU is recommended. Conclusion: the PTW EPID QC PHANTOM registered can be used not only for amorphous silicon EPIDs but also for images taken with a video-based system or by using an ionization chamber matrix or for portal film. For analysis of QC tests, a standardized format (used at the acceptance test) should be applied, as the results are dependent on the file format used. (orig.)

  6. Ozone (Environmental Health Student Portal)

    Science.gov (United States)

    Skip Navigation National Library of Medicine Environmental Health Student Portal Connecting Middle School Students to Environmental Health Information Menu Home Air Pollution Air Pollution Home Indoor Air Pollution Outdoor ...

  7. Pesticides (Environmental Health Student Portal)

    Science.gov (United States)

    Skip Navigation National Library of Medicine Environmental Health Student Portal Connecting Middle School Students to Environmental Health Information Menu Home Air Pollution Air Pollution Home Indoor Air Pollution Outdoor ...

  8. Radioisotopic evaluation of portal circulation

    International Nuclear Information System (INIS)

    Maliska, C.; Rosenthal, D.

    1986-01-01

    The use of a radio-tracer of portal circulation through the intestine, should prevent cruel punctures in the portal-vein or spleen as it is usually the case with traditional methods in the study of portal-system. The absorption of I-131 and Tc-99m, previously cheked in rabbits presented similar results in dogs. The time of circulation between terminal large-intestine and the liver (t-RF) was determined by external counting at hepatic level by recording radioactivity variation-time. In healthy animals the t-RF was from 20to 60 seconds, with average time of 42 seconds. In 2 animals with partial binding of portal-vein the t-RF went up to 110 and 120 seconds. (Author) [pt

  9. Alarm criteria in radiation portal monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Burr, Tom [Los Alamos National Laboratory, Statistical Sciences Group, Mail Stop F600, Los Alamos, NM 87545 (United States)]. E-mail: tburr@lanl.gov; Gattiker, James R. [Los Alamos National Laboratory, Statistical Sciences Group, Mail Stop F600, Los Alamos, NM 87545 (United States); Myers, Kary [Los Alamos National Laboratory, Statistical Sciences Group, Mail Stop F600, Los Alamos, NM 87545 (United States); Tompkins, George [Los Alamos National Laboratory, Risk Analysis and Decision Support Systems, Stop F609, Los Alamos, NM 87545 (United States)

    2007-05-15

    Gamma detectors at border crossings are intended to detect illicit nuclear material. These detectors collect counts that are used to determine whether to trigger an alarm. Several candidate alarm rules are evaluated, with attention to background suppression caused by the vehicle. Because the count criterion leads to many nuisance alarms and because background suppression by the vehicle is smaller for ratios of counts, analysis of a ratio criterion is included. Detection probability results that consider the effects of 5 factors are given for 2 signal-injection studies, 1 for counts, and 1 for count ratios.

  10. Alarm criteria in radiation portal monitoring

    International Nuclear Information System (INIS)

    Burr, Tom; Gattiker, James R.; Myers, Kary; Tompkins, George

    2007-01-01

    Gamma detectors at border crossings are intended to detect illicit nuclear material. These detectors collect counts that are used to determine whether to trigger an alarm. Several candidate alarm rules are evaluated, with attention to background suppression caused by the vehicle. Because the count criterion leads to many nuisance alarms and because background suppression by the vehicle is smaller for ratios of counts, analysis of a ratio criterion is included. Detection probability results that consider the effects of 5 factors are given for 2 signal-injection studies, 1 for counts, and 1 for count ratios

  11. Portal pressure correlated to visceral circulation times

    Energy Technology Data Exchange (ETDEWEB)

    Friman, L [Serafimerlasarettet, Stockholm (Sweden)

    1979-01-01

    Visceral angiography was performed in 7 patients with normal portal pressure and in 10 with portal hypertension. Circulation times, size of vessels and portal pressure were determined. At celiac angiography, a direct correlation was found between time for maximum filling of portal vein and portal pressure, provided no vascular abnormalities existed. At superior mesenteric angiography such a correlation was not found; loss of flow by shunts in portal hypertension being one explanation. Portocaval shunts are common in the celiac system, but uncommon in the superior mesenteric system.

  12. Portal pressure correlated to visceral circulation times

    International Nuclear Information System (INIS)

    Friman, L.

    1979-01-01

    Visceral angiography was performed in 7 patients with normal portal pressure and in 10 with portal hypertension. Circulation times, size of vessels and portal pressure were determined. At celiac angiography, a direct correlation was found between time for maximum filling of portal vein and portal pressure, provided no vascular abnormalities existed. At superior mesenteric angiography such a correlation was not found; loss of flow by shunts in portal hypertension being one explanation. Portocaval shunts are common in the celiac system, but uncommon in the superior mesenteric system. (Auth.)

  13. Portal monitor incorporating smart probes

    International Nuclear Information System (INIS)

    Bartos, D.; Constantin, F.; Guta, T.

    2003-01-01

    Portal monitors are intended for detection of radioactive and special nuclear materials in vehicles, pedestrians, luggage, as well as for prevention of illegal traffic of radioactive sources. Monitors provide audio and visual alarms when radioactive and/or special nuclear materials are detected. They can be recommended to officers of customs, border guard and emergency services, civil defense, fire brigades, police and military departments or nuclear research or energetic facilities. The portal monitor developed by us consists in a portal frame, which sustains five intelligent probes having long plastic scintillator (0.5 liters each). The probes communicate, by serial transmission, with a Central Unit constructed on the basis of the 80552 microcontroller. This one manages the handshake, calculates the background, establishes the measuring time, starts and stops each measurement and makes all the other decisions. Sound signals and an infrared sensor monitor the passing through the portal and the measuring procedure. For each measurement the result is displayed on a LCD device contaminated/uncontaminated; for the contaminated case a loud and long sound signal is also issued. An RS 232 serial interface is provided in order to further developments or custom made devices. As a result, the portal monitor detects 1 μ Ci 137 Cs, spread all over a human body, in a 20 μR/h gamma background for a measuring time of 1.5 or 10 seconds giving a 99% confidence factor. (authors)

  14. CT findings of portal vein aneurysm

    International Nuclear Information System (INIS)

    Yang, Dal Mo; Chang, Mi Son; Yoon, Myung Hwan; Kim, Hak Soo; Kim, Hyung Sik; Chung, Hyo Sun; Chung, Jin Woo

    1999-01-01

    To describe the CT findings of portal vein aneurysm in eight patients. All patients included in this study (two men and six women) underwent CT examinations between October 1996 and June1998. Of these eight, three were suffering from hepatic disease and portal hypertension. We determined the location, shape, size, and characteristics of the lesions, and the presence or absence of portal vein anomaly. Seven patients had intrahepatic portal vein aneurysm (at the umbilical portion of the left portal vein in five patients, between the transverse and umbilical portion of the left portal vein in one, and at the bifurcation of the anterior and posterior branch of the right portal vein in one), while extrahepatic portal vein aneurysm, at the confluence of the superior mesenteric and splenic vein was found in only one. Lesions were cyst-shaped in seven cases and saccular in one, and showed well-circumscribed, markedly enhanced mass, which communicated with the portal vein and/or gives off major branches. Portal vein anomaly, in which the right anterior segmental portal vein originated from the umbilical portion of the left portal vein, was seen in three patients. In all three, intrahepatic portal vein aneurysm was present at the umbilical portion of the left portal vein, and in one, the umbilical protion of the left portal vein was located to the right of the Cantlic line. CT examination can help reveal portal vein aneurysm by detecting a well-circumscribed, markedly enhanced mass which communicates with the portal vein and/or gives off major branches

  15. The Higgs portal above threshold

    Energy Technology Data Exchange (ETDEWEB)

    Craig, Nathaniel [Department of Physics, University of California,Santa Barbara, CA 93106 (United States); Lou, Hou Keong [Department of Physics, Princeton University,Princeton, NJ 08540 (United States); McCullough, Matthew [Theory Division, CERN,1211 Geneva 23 (Switzerland); Thalapillil, Arun [Department of Physics and Astronomy, Rutgers University,Piscataway, NJ 08854 (United States)

    2016-02-18

    The discovery of the Higgs boson opens the door to new physics interacting via the Higgs Portal, including motivated scenarios relating to baryogenesis, dark matter, and electroweak naturalness. We systematically explore the collider signatures of singlet scalars produced via the Higgs Portal at the 14 TeV LHC and a prospective 100 TeV hadron collider. We focus on the challenging regime where the scalars are too heavy to be produced in the decays of an on-shell Higgs boson, and instead are produced primarily via an off-shell Higgs. Assuming these scalars escape the detector, promising channels include missing energy in association with vector boson fusion, monojets, and top pairs. We forecast the sensitivity of searches in these channels at √s=14 & 100 TeV and compare collider reach to the motivated parameter space of singlet-assisted electroweak baryogenesis, Higgs Portal dark matter, and neutral naturalness.

  16. The Higgs portal above threshold

    International Nuclear Information System (INIS)

    Craig, Nathaniel; Lou, Hou Keong; McCullough, Matthew; Thalapillil, Arun

    2016-01-01

    The discovery of the Higgs boson opens the door to new physics interacting via the Higgs Portal, including motivated scenarios relating to baryogenesis, dark matter, and electroweak naturalness. We systematically explore the collider signatures of singlet scalars produced via the Higgs Portal at the 14 TeV LHC and a prospective 100 TeV hadron collider. We focus on the challenging regime where the scalars are too heavy to be produced in the decays of an on-shell Higgs boson, and instead are produced primarily via an off-shell Higgs. Assuming these scalars escape the detector, promising channels include missing energy in association with vector boson fusion, monojets, and top pairs. We forecast the sensitivity of searches in these channels at √s=14 & 100 TeV and compare collider reach to the motivated parameter space of singlet-assisted electroweak baryogenesis, Higgs Portal dark matter, and neutral naturalness.

  17. Radiation

    International Nuclear Information System (INIS)

    2013-01-01

    The chapter one presents the composition of matter and atomic theory; matter structure; transitions; origin of radiation; radioactivity; nuclear radiation; interactions in decay processes; radiation produced by the interaction of radiation with matter

  18. Building an Archival Collections Portal

    Directory of Open Access Journals (Sweden)

    Stuart Marquis

    2008-06-01

    Full Text Available Columbia University Libraries has developed the Archival Collections Portal, a unified search system helping users discover archival resources in a streamlined way. We combined the power of Lucene and Solr to search XML, parse JSON objects, create EAD-compliant documents, and deliver results in an easy-to-use interface. By reusing MARC records and employing new search engine features and techniques, we are able to bring important and hard-to-find collections to researchers and archivists. The canonical home page of the Portal is http://www.columbia.edu/library/archival/.

  19. 29 CFR 785.24 - Principles noted in Portal-to-Portal Bulletin.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 3 2010-07-01 2010-07-01 false Principles noted in Portal-to-Portal Bulletin. 785.24 Section 785.24 Labor Regulations Relating to Labor (Continued) WAGE AND HOUR DIVISION, DEPARTMENT OF LABOR... of Principles Preparatory and Concluding Activities § 785.24 Principles noted in Portal-to-Portal...

  20. From EGEE Operations Portal towards EGI Operations Portal

    Science.gov (United States)

    Cordier, Hélène; L'Orphelin, Cyril; Reynaud, Sylvain; Lequeux, Olivier; Loikkanen, Sinikka; Veyre, Pierre

    Grid operators in EGEE have been using a dedicated dashboard as their central operational tool, stable and scalable for the last 5 years despite continuous upgrade from specifications by users, monitoring tools or data providers. In EGEE-III, recent regionalisation of operations led the Operations Portal developers to conceive a standalone instance of this tool. We will see how the dashboard reorganization paved the way for the re-engineering of the portal itself. The outcome is an easily deployable package customized with relevant information sources and specific decentralized operational requirements. This package is composed of a generic and scalable data access mechanism, Lavoisier; a renowned php framework for configuration flexibility, Symfony and a MySQL database. VO life cycle and operational information, EGEE broadcast and Downtime notifications are next for the major reorganization until all other key features of the Operations Portal are migrated to the framework. Features specifications will be sketched at the same time to adapt to EGI requirements and to upgrade. Future work on feature regionalisation, on new advanced features or strategy planning will be tracked in EGI- Inspire through the Operations Tools Advisory Group, OTAG, where all users, customers and third parties of the Operations Portal are represented from January 2010.

  1. Magnetic Resonance Imaging of a Liver Hydatid Cyst Invading the Portal Vein and Causing Portal Cavernomatosis.

    Science.gov (United States)

    Herek, Duygu; Sungurtekin, Ugur

    2015-01-01

    Hepatic hydatid cysts rarely invade portal veins causing portal cavernomatosis as a secondary complication. We report the case of a patient with direct invasion of the right portal vein by hydatid cysts causing portal cavernomatosis diagnosed via magnetic resonance imaging (MRI). The presented case highlights the useful application of MRI with T2-weighted images and gadolinium-enhanced T1-weighted images in the diagnosis of hepatic hydatid lesions presenting with a rare complication of portal cavernomatosis.

  2. Radiologic investigation of portal hypertension

    International Nuclear Information System (INIS)

    Becker, C.; Wegmueller, H.

    1993-01-01

    Radiologic evaluation of patients with portal hypertension in the pre- and postoperative period can be done with several non-invasive or invasive imaging modalities which offer complementary information. Doppler-ultrasonography (-US) is the method of choice for initial non-invasive screening as well as for follow-up tests after shunt surgery. The diagnostic information provided by Doppler-US regarding morphology and blood flow in the upper abdominal organs and vessels is sufficient in many instances. Dynamic computed tomography (CT), magnetic resonance tomography (MRT) and recently, magnetic resonance angiography (MRA) are additional non-invasive imaging techniques that may add valuable information if necessary. Conventional angiography is usually performed immediately prior to surgery to demonstrate the vascular morphology. The standard angiographic technique to demonstrate both the arterial and portal venous system is arterioportography (late-phase portography) by means of selective catheterization of the celiac, the splenic, the superior mesenteric or inferior mesenteric arteries. The dose of iodinated contrast material may be reduced by 50% if digital subtraction angiography is used instead of the conventional technique. Inferior venacavography and hepatic venography are indicated in patients with suspected postsinusoidal portal hypertension, e.g. the Budd-Chiari syndrome; hepatic wedge manometry offers valuable information regarding pressure gradients between the portal and systemic venous system prior to shunt surgery. The angiographic access through the inferior vena cava is also used for direct catheterization of surgical porto-caval or spleno-renal shunts for both angiography, manometry and, if necessary, balloon angioplasty. (authors)

  3. Proceedings of the technical exchange meeting on passive radon monnitoring

    Energy Technology Data Exchange (ETDEWEB)

    Duray, J.R.; Langner, H. Jr.; Martz, D.E.

    1987-09-01

    The purpose of the meeting was to bring together a number of scientists active in the development and use of passive radon monitoring instrumentation, primarily activated charcoal detectors and alpha track detectors. Many of those present expressed a desire to receive copies of the viewgraphs and other materials presented. Most have supplied extended abstracts or complete reports. These materials are reproduced here as a Technical Measurements Center Report for the benefit of those attending the meeting and for others interested in passive radon monitoring. Individual papers were processed separately for the data base.

  4. Proceedings of the technical exchange meeting on passive radon monnitoring

    International Nuclear Information System (INIS)

    Duray, J.R.; Langner, H. Jr.; Martz, D.E.

    1987-09-01

    The purpose of the meeting was to bring together a number of scientists active in the development and use of passive radon monitoring instrumentation, primarily activated charcoal detectors and alpha track detectors. Many of those present expressed a desire to receive copies of the viewgraphs and other materials presented. Most have supplied extended abstracts or complete reports. These materials are reproduced here as a Technical Measurements Center Report for the benefit of those attending the meeting and for others interested in passive radon monitoring. Individual papers were processed separately for the data base

  5. Sonographic detection of portal venous gas

    International Nuclear Information System (INIS)

    Lee, Wang Yul; Lee, S. K.; Cho, O. K.

    1989-01-01

    Portal venous gas suggests underlying bowel disease such as strangulating intestinal obstruction and its demonstration carries with it an important implications with respect to patient management. Radiography has been the gold standard for the detection of portal venous gas. We have experienced two cases of portal venous gas diagnosed by ultrasound. Sonographic findings were floating echoes in the main portal vein and highly echogenic linear or patchy echoes within the hepatic parenchyma. Simple abdominal films of those cases failed to demonstrate gas in the portal venous system

  6. Radioactivity Portal Monitor: An actual application and its unconventional detector

    International Nuclear Information System (INIS)

    Izraelevitch, F.; Matatagui, E.; Regueiro Veiga, J.L.

    2012-01-01

    A Radioactivity Portal Monitor is an instrument designed to be used at traffic check points to detect the presence of ionizing radiation in goods, vehicles, people, in critical places such as those at border road crossing, airports and seaports, the entrance at nuclear facilities etc. and alert the officer to the presence of radioactive and nuclear material. We have developed and built, and is in operation a Radioactivity Portal Monitor for gamma radiation. The detector and the associated electronics does not follow a conventional design concept and is based on a pressurized ionization chamber with a very large sensitive volume (60 liters) and a very large length (2 meters), and a very low level DC electronics (fAmp). The System is simple, and its operational characteristics are excellent. The reference radiation level is the background radiation, which is continuously measured, and compared with the radiation level measured when a subject (vehicle, person, good) goes trough the Monitor. The system automatically takes a decision, and alert the officer with an alarm signal if the detected radiation level is larger than the reference (dynamical) level. We will describe the designed system and some of its characterization results will be shown (author)

  7. Intelligent interaction based on holographic personalized portal

    Directory of Open Access Journals (Sweden)

    Yadong Huang

    2017-06-01

    Full Text Available Purpose – The purpose of this paper is to study the architecture of holographic personalized portal, user modeling, commodity modeling and intelligent interaction. Design/methodology/approach – In this paper, the authors propose crowd-science industrial ecological system based on holographic personalized portal and its interaction. The holographic personality portal is based on holographic enterprises, commodities and consumers, and the personalized portal consists of accurate ontology, reliable supply, intelligent demand and smart cyberspace. Findings – The personalized portal can realize the information acquisition, characteristic analysis and holographic presentation. Then, the intelligent interaction, e.g. demand decomposition, personalized search, personalized presentation and demand prediction, will be implemented within the personalized portal. Originality/value – The authors believe that their work on intelligent interaction based on holographic personalized portal, which has been first proposed in this paper, is innovation focusing on the interaction between intelligence and convenience.

  8. Importance of daily electronic portal imaging in radiotherapy

    International Nuclear Information System (INIS)

    Bell, L. J.; Shakespeare, T. P.; Willis, A.

    2008-01-01

    Full text: An audit was conducted on 20 randomly selected patients who had daily electronic portal imaging during the course of their radiotherapy treatment. The daily images were reviewed to determine whether they were within tolerance according to departmental protocol. If they were not, the actions that were taken were documented. Four treatment areas (spine, chest, breast and prostate) were compared among five patients belonging to each of these categories. The patients were also categorized according to their treatment intent (radical or palliative). A total of 889 electronic portal images of 475 fractions were audited and 33.5% of all fractions were outside tolerance. It was found that 95% of patients needed an action during their treatment and 80% of the patients needed a treatment centre move during the course of their treatment. We found that errors occurred throughout the treatment and it was not possible to predict patients who could have daily imaging omitted. Concordance between radiation therapists and radiation oncologists for identification of error was also investigated. Despite the use of familiar electronic portal imaging protocols, image reviewers (radiation therapists and radiation oncologists) disagreed in interpretation 10% of the time. Our results support the hypothesis that daily imaging may be a useful tool for patients undergoing radiotherapy and that imaging may be ideally carried out before each fraction. Image assessments would be ideally carried out by a team approach, with all images reviewed by both radiation therapists and radiation oncologists. This approach has significant resource implications and may require review of current Medicare and Health Program Grant reimbursements.

  9. Use of Portal Monitors for Detection of Technogenic Radioactive Sources in Scrap Metal

    Science.gov (United States)

    Solovev, D. B.; Merkusheva, A. E.

    2017-11-01

    The article considers the features of organization of scrap-metal primary radiation control on the specialized enterprises engaging in its deep processing and storage at using by primary technical equipment - radiation portal monitors. The issue of this direction relevance, validity of radiation control implementation with the use of radiation portal monitors, physical and organizational bases of radiation control are considered in detail. The emphasis is put on the considerable increase in the number of technogenic radioactive sources detected in scrap-metal that results in the entering into exploitation of radioactive metallic structures as different building wares. One of reasons of such increase of the number of technogenic radioactive sources getting for processing with scrap-metal is the absence of any recommendations on the radiation portal monitors exploitation. The practical division of the article offers to recommendation on tuning of the modes of work of radiation portal monitors depending on influence the weather factor thus allowing to considerably increase the percent of technogenic radioactive sources detection.

  10. The secondary metabolite bioinformatics portal

    DEFF Research Database (Denmark)

    Weber, Tilmann; Kim, Hyun Uk

    2016-01-01

    . In this context, this review gives a summary of tools and databases that currently are available to mine, identify and characterize natural product biosynthesis pathways and their producers based on ‘omics data. A web portal called Secondary Metabolite Bioinformatics Portal (SMBP at http...... analytical and chemical methods gave access to this group of compounds, nowadays genomics-based methods offer complementary approaches to find, identify and characterize such molecules. This paradigm shift also resulted in a high demand for computational tools to assist researchers in their daily work......Natural products are among the most important sources of lead molecules for drug discovery. With the development of affordable whole-genome sequencing technologies and other ‘omics tools, the field of natural products research is currently undergoing a shift in paradigms. While, for decades, mainly...

  11. Quality assurance for electronic portal imaging devices

    International Nuclear Information System (INIS)

    Shalev, S.; Rajapakshe, R.; Gluhchev, G.; Luchka, K.

    1997-01-01

    Electronic portal imaging devices (EPIDS) are assuming an ever-increasing role in the verification of radiation treatment accuracy. They are used both in a passive capacity, for the determination of field displacement distributions (''setup errors''), and also in an active role whereby the patient setup is corrected on the basis of electronic portal images. In spite of their potential impact on the precision of patient treatment, there are few quality assurance procedures available, and most of the EPIDS in clinical use are subject, at best, to only perfunctory quality assurance. The goals of this work are (a) to develop an objective and reproducible test for EPID image quality on the factory floor and during installation of the EPID on site; (b) to provide the user with a simple and accurate tool for acceptance, commissioning, and routine quality control; and (c) to initiate regional, national and international collaboration in the implementation of standardized, objective, and automated quality assurance procedures. To this end we have developed an automated test in which a simple test object is imaged daily, and the spatial and contrast resolution of the EPID are automatically evaluated in terms of ''acceptable'', ''warning'' and ''stop'' criteria. Our experience over two years shows the test to be highly sensitive, reproducible, and inexpensive in time and effort. Inter-institutional trials are under way in Canada, US and Europe which indicate large variations in EPID image quality from one EPID to another, and from one center to another. We expect the new standardized quality assurance procedure to lead to improved, and consistent image quality, increased operator acceptance of the technology, and agreement on uniform standards by equipment suppliers and health care agencies. (author)

  12. Quality control of portal imaging with PTW EPID QC PHANTOM {sup registered}

    Energy Technology Data Exchange (ETDEWEB)

    Pesznyak, Csilla; Kiraly, Reka; Polgar, Istvan; Zarand, Pal; Mayer, Arpad [Inst. of Oncoradiology, Uzsoki Hospital, Budapest (Hungary); Fekete, Gabor [Dept. of Oncotherapy, Univ. of Szeged (Hungary); Mozes, Arpad [Oncology Center, Kalman Pandy County Hospital, Gyula (Hungary); Kiss, Balazs [Dept. of Radiation Oncology, Markusovszky County Hospital, Szombathely (Hungary)

    2009-01-15

    Purpose: quality assurance (QA) and quality control (QC) of different electronic portal imaging devices (EPID) and portal images with the PTW EPID QC PHANTOM {sup registered}. Material and methods: characteristic properties of images of different file formats were measured on Siemens OptiVue500aSi {sup registered}, Siemens BeamView Plus {sup registered}, Elekta iView {sup registered}, and Varian PortalVision trademark and analyzed with the epidSoft {sup registered} 2.0 program in four radiation therapy centers. The portal images were taken with Kodak X-OMAT V {sup registered} and the Kodak Portal Localisation ReadyPack {sup registered} films and evaluated with the same program. Results: the optimal exposition both for EPIDs and portal films of different kind was determined. For double exposition, the 2+1 MU values can be recommended in the case of Siemens OptiVue500aSi {sup registered}, Elekta iView {sup registered} and Kodak Portal Localisation ReadyPack {sup registered} films, while for Siemens BeamView Plus {sup registered}, Varian PortalVision trademark and Kodak X-OMAT V {sup registered} film 7+7 MU is recommended. Conclusion: the PTW EPID QC PHANTOM {sup registered} can be used not only for amorphous silicon EPIDs but also for images taken with a video-based system or by using an ionization chamber matrix or for portal film. For analysis of QC tests, a standardized format (used at the acceptance test) should be applied, as the results are dependent on the file format used. (orig.)

  13. Treatment of portal hypertension caused by benign main portal vein stenosis with endovascular stent

    International Nuclear Information System (INIS)

    Huang Mingsheng; Shan Hong; Jiang Zaibo; Guan Shouhai; Zhu Kangshun; Li Zhengran; Zhou Yubin; He Bingjun

    2004-01-01

    Objective: To evaluate the value of endovascular stent in the treatment of portal hypertension caused by benign main portal vein stenosis. Methods: Portal vein stents were implanted in 6 patients with benign main portal vein stenosis (inflammatory stenosis in 3 cases, postprocedure of liver transplantation in another 3 cases). The change of portal vein pressure, the patency of portal vein, relative clinical symptoms, complications, and survival were evaluated. Results: Six metallic stents were successfully placed across the portal vein stenotic or obstructive lesions in all 6 patients. Mean portal venous pressure decreased significantly after stent implantation from (37.3 ± 4.7) cm H 2 O (1 cm H 2 O=0.098 kPa) to (18.0 ± 1.9) cm H 2 O (P<0.001). The portal blood flow was restored, and the symptoms caused by portal hypertension were eliminated. There was no severe procedure-related complication. Follow-up time was from 5 to 36 months. The portal vein remained patent during the follow-up. All patients survived except one patient who died of other complications of liver transplantation. Conclusion: Percutaneous portal vein stent placement for the treatment of the benign main portal vein stenosis is safe and effective. (authors)

  14. submitter The Muon Portal Project: Design and construction of a scanning portal based on muon tomography

    CERN Document Server

    Antonuccio, V; Becciani, U; Bonanno, D L; Bonanno, G; Bongiovanni, D; Fallica, P G; Garozzo, S; Grillo, A; La Rocca, P; Leonora, E; Longhitano, F; Lo Presti, D; Marano, D; Parasole, O; Pugliatti, C; Randazzo, N; Riggi, F; Riggi, S; Romeo, G; Romeo, M; Russo, G V; Santagati, G; Timpanaro, M C; Valvo, G

    2017-01-01

    Cosmic ray tomography is a technique which exploits the multiple Coulomb scattering of highly penetrating cosmic ray-produced muons to perform non-destructive inspection of high-Z materials without the use of artificial radiation. A muon tomography detection system can be used as a portal monitor at border crossing points for detecting illegal targeted objects. The Muon Portal Project is a joint initiative between Italian research and industrial partners, aimed at the construction of a real size detector prototype $(6×3×7 m^3)$ for the inspection of cargo containers by the muon scattering technique. The detector consists of four XY tracking planes, two placed above and two below the container to be inspected. After a research and development phase, which led to the choice and test of the individual components, the construction and installation of the detection modules is almost completed. In this paper the present status of the Project is reported, focusing on the design and construction phase, as well as o...

  15. The Muon Portal Project: Design and construction of a scanning portal based on muon tomography

    Energy Technology Data Exchange (ETDEWEB)

    Antonuccio, V. [INAF - Osservatorio Astrofisico di Catania (Italy); Bandieramonte, M. [CERN, Geneva (Switzerland); Becciani, U. [INAF - Osservatorio Astrofisico di Catania (Italy); Bonanno, D.L., E-mail: danilo.bonanno@ct.infn.it [INFN Sezione di Catania, Catania (Italy); Bonanno, G. [INAF - Osservatorio Astrofisico di Catania (Italy); Bongiovanni, D. [INFN Sezione di Catania, Catania (Italy); Fallica, P.G. [STMicroelectronics, Catania (Italy); Garozzo, S.; Grillo, A. [INAF - Osservatorio Astrofisico di Catania (Italy); La Rocca, P. [INFN Sezione di Catania, Catania (Italy); Dipartimento di Fisica e Astronomia, Università di Catania, Catania (Italy); Leonora, E.; Longhitano, F. [INFN Sezione di Catania, Catania (Italy); Lo Presti, D. [INFN Sezione di Catania, Catania (Italy); Dipartimento di Fisica e Astronomia, Università di Catania, Catania (Italy); Marano, D. [INAF - Osservatorio Astrofisico di Catania (Italy); Parasole, O. [INFN Sezione di Catania, Catania (Italy); Dipartimento di Fisica e Astronomia, Università di Catania, Catania (Italy); Pugliatti, C. [Dipartimento di Fisica e Astronomia, Università di Catania, Catania (Italy); Randazzo, N. [INFN Sezione di Catania, Catania (Italy); Riggi, F. [INFN Sezione di Catania, Catania (Italy); Dipartimento di Fisica e Astronomia, Università di Catania, Catania (Italy); Riggi, S. [INAF - Osservatorio Astrofisico di Catania (Italy); INFN Sezione di Catania, Catania (Italy); Romeo, G. [INAF - Osservatorio Astrofisico di Catania (Italy); and others

    2017-02-11

    Cosmic ray tomography is a technique which exploits the multiple Coulomb scattering of highly penetrating cosmic ray-produced muons to perform non-destructive inspection of high-Z materials without the use of artificial radiation. A muon tomography detection system can be used as a portal monitor at border crossing points for detecting illegal targeted objects. The Muon Portal Project is a joint initiative between Italian research and industrial partners, aimed at the construction of a real size detector prototype (6×3×7 m{sup 3}) for the inspection of cargo containers by the muon scattering technique. The detector consists of four XY tracking planes, two placed above and two below the container to be inspected. After a research and development phase, which led to the choice and test of the individual components, the construction and installation of the detection modules is almost completed. In this paper the present status of the Project is reported, focusing on the design and construction phase, as well as on the preliminary results obtained with the first detection planes.

  16. The Muon Portal Project: Design and construction of a scanning portal based on muon tomography

    Science.gov (United States)

    Antonuccio, V.; Bandieramonte, M.; Becciani, U.; Bonanno, D. L.; Bonanno, G.; Bongiovanni, D.; Fallica, P. G.; Garozzo, S.; Grillo, A.; La Rocca, P.; Leonora, E.; Longhitano, F.; Lo Presti, D.; Marano, D.; Parasole, O.; Pugliatti, C.; Randazzo, N.; Riggi, F.; Riggi, S.; Romeo, G.; Romeo, M.; Russo, G. V.; Santagati, G.; Timpanaro, M. C.; Valvo, G.

    2017-02-01

    Cosmic ray tomography is a technique which exploits the multiple Coulomb scattering of highly penetrating cosmic ray-produced muons to perform non-destructive inspection of high-Z materials without the use of artificial radiation. A muon tomography detection system can be used as a portal monitor at border crossing points for detecting illegal targeted objects. The Muon Portal Project is a joint initiative between Italian research and industrial partners, aimed at the construction of a real size detector prototype (6×3×7 m3) for the inspection of cargo containers by the muon scattering technique. The detector consists of four XY tracking planes, two placed above and two below the container to be inspected. After a research and development phase, which led to the choice and test of the individual components, the construction and installation of the detection modules is almost completed. In this paper the present status of the Project is reported, focusing on the design and construction phase, as well as on the preliminary results obtained with the first detection planes.

  17. The effect of partial portal decompression on portal blood flow and effective hepatic blood flow in man: a prospective study.

    Science.gov (United States)

    Rosemurgy, A S; McAllister, E W; Godellas, C V; Goode, S E; Albrink, M H; Fabri, P J

    1995-12-01

    With the advent of transjugular intrahepatic porta-systemic stent shunt and the wider application of the surgically placed small diameter prosthetic H-graft portacaval shunt (HGPCS), partial portal decompression in the treatment of portal hypertension has received increased attention. The clinical results supporting the use of partial portal decompression are its low incidence of variceal rehemorrhage due to decreased portal pressures and its low rate of hepatic failure, possibly due to maintenance of blood flow to the liver. Surprisingly, nothing is known about changes in portal hemodynamics and effective hepatic blood flow following partial portal decompression. To prospectively evaluate changes in portal hemodynamics and effective hepatic blood flow brought about by partial portal decompression, the following were determined in seven patients undergoing HGPCS: intraoperative pre- and postshunt portal vein pressures and portal vein-inferior vena cava pressure gradients, intraoperative pre- and postshunt portal vein flow, and pre- and postoperative effective hepatic blood flow. With HGPCS, portal vein pressures and portal vein-inferior vena cava pressure gradients decreased significantly, although portal pressures remained above normal. In contrast to the significant decreases in portal pressures, portal vein blood flow and effective hepatic blood flow do not decrease significantly. Changes in portal vein pressures and portal vein-inferior vena cava pressure gradients are great when compared to changes in portal vein flow and effective hepatic blood flow. Reduction of portal hypertension with concomitant maintenance of hepatic blood flow may explain why hepatic dysfunction is avoided following partial portal decompression.

  18. The questions of working out radiology patterns of portal hypertension

    International Nuclear Information System (INIS)

    Vyikman, Ya.E.

    2008-01-01

    A foundation for radiological patterns of each type of portal hypertension (PH) at various stages of its development. Portal blood pressure, diameter of splenic and portal veins, volume blood flow velocity in the portal and splenic veins, incidence of hypersplenism, enlargement of the caudate lobe of the liver and gallbladder fossa are the most informative in differentiation of various forms of portal hypertension

  19. Cavernous transformation of the portal vein

    International Nuclear Information System (INIS)

    Lehotska, V.; Dostalova, K.; Durkovsky, A.; Samal, V.

    1995-01-01

    In this contribution, the authors give an account of a rare case of a cavernous transformation of the portal vein that may have originated secondarily in a proliferative hematogenous disease with a polyglobulia and thrombosis in the periferal blood count as well as development of portal hypertension of a prehepatal type. The state of hyper-coagulation in a myeloproliferative disease may have lead to a chronic thrombosis of the portal vein with a subsequent malformation of the portal vein in terms of a cavernous transformation of the portal vein. The case is an interesting one because of the discrepancy between the gravity of the thrombotic complication and slightness of the symptoms in the clinical picture. The authors point out the importance of ultrasonography and computed tomography examination following the intravenous application of a water solution of a contrast medium in a morphologic diagnosing of a rare complication of a chronic thrombotic clot of the portal vein - the cavernous transformation. (authors)

  20. [Predictive value of ultrasonography in portal hypertension].

    Science.gov (United States)

    Moreno, E; Torres, P; Trejo, C; Barra Ostoni, V; Ortega, C; Römer, H

    1991-01-01

    Portal hypertension is a common pathology in childhood and one of its most common causes is cavernomatosis of the portal vein. This obstruction causes hemodynamic changes which lead to splenomegaly and collateral circulation. Esophageal varices are one of the most important sequelae, which endanger the patient's life because of a bleeding tendency. Ecosonography helps to detect the thickening of the lesser omentum vis a vis the aortic diameter, caused by the collateral circulation. We studied 15 children presenting with portal hypertension resulting from portal vein cavernomatosis; we performed an upper GI endoscopy and abdominal ecosonography. The endoscopy revealed grade II esophageal varices in 20% of cases, the remaining 80% had grade III and grade IV. Ecosonography revealed an increased lesser omentum/aorta ratio in children with portal hypertension, compared to controls (p portal hypertension.

  1. Determining the optimal portal blood volume in a shunt before surgery in extrahepatic portal hypertension

    Directory of Open Access Journals (Sweden)

    Yurchuk Vladimir A

    2016-04-01

    Full Text Available The aim of the study: To determine the necessary shunt diameter and assess the optimal portal blood volume in a shunt in children with extrahepatic portal hypertension before the portosystemic shunt surgery. Changes in the liver hemodynamics were studied in 81 children aged from 4 to 7 years with extrahepatic portal hypertension. We established that it is necessary to calculate the shunt diameter and the blood volume in a shunt in patients with extrahepatic portal hypertension before the portosystemic shunt surgery. It allows us to preserve the hepatic portal blood flow and effectively decrease the pressure in the portal system. Portosystemic shunt surgery in patients with extrahepatic portal hypertension performed in accordance with the individualized shunt volume significantly decreases portal pressure, preserves stable hepatic hemodynamics and prevents gastro-esophageal hemorrhage.

  2. Prospective clinical evaluation of an electronic portal imaging device

    International Nuclear Information System (INIS)

    Michalski, Jeff M.; Graham, Mary V.; Bosch, Walter R.; Wong, John; Gerber, Russell L.; Cheng, Abel; Tinger, Alfred; Valicenti, Richard K.

    1996-01-01

    Purpose: To determine whether the clinical implementation of an electronic portal imaging device can improve the precision of daily external beam radiotherapy. Methods and Materials: In 1991, an electronic portal imaging device was installed on a dual energy linear accelerator in our clinic. After training the radiotherapy technologists in the acquisition and evaluation of portal images, we performed a randomized study to determine whether online observation, interruption, and intervention would result in more precise daily setup. The patients were randomized to one of two groups: those whose treatments were actively monitored by the radiotherapy technologists and those that were imaged but not monitored. The treating technologists were instructed to correct the following treatment errors: (a) field placement error (FPE) > 1 cm; (b) incorrect block; (c) incorrect collimator setting; (d) absent customized block. Time of treatment delivery was recorded by our patient tracking and billing computers and compared to a matched set of patients not participating in the study. After the patients radiation therapy course was completed, an offline analysis of the patient setup error was planned. Results: Thirty-two patients were treated to 34 anatomical sites in this study. In 893 treatment sessions, 1,873 fields were treated (1,089 fields monitored and 794 fields unmonitored). Ninety percent of the treated fields had at least one image stored for offline analysis. Eighty-seven percent of these images were analyzed offline. Of the 1,011 fields imaged in the monitored arm, only 14 (1.4%) had an intervention recorded by the technologist. Despite infrequent online intervention, offline analysis demonstrated that the incidence of FPE > 10 mm in the monitored and unmonitored groups was 56 out of 881 (6.1%) and 95 out of 595 (11.2%), respectively; p 10 mm was confined to the pelvic fields. The time to treat patients in this study was 10.78 min (monitored) and 10.10 min (unmonitored

  3. Noncirrhotic portal fibrosis after Wilms' tumor therapy

    International Nuclear Information System (INIS)

    Barnard, J.A.; Marshall, G.S.; Neblett, W.W.; Gray, G.; Ghishan, F.K.

    1986-01-01

    A 9-yr-old girl developed massive hemorrhage from esophageal varices 2 yr after combined modality therapy for Wilms' tumor. Evaluation showed a patent extrahepatic portal venous system and an elevated splenic pulp pressure. In contrast to previous reports of hepatopathy after irradiation injury, histologic sections of the liver did not demonstrate occlusion of the central veins, but rather a diffuse obliteration of intrahepatic portal venous radicles. This pattern of noncirrhotic portal fibrosis has not been described following antitumor therapy

  4. A View on Electronic Learning Portals

    OpenAIRE

    Zavaraqi, Rasoul

    2009-01-01

    Portals are less than a decade old. They have come to cover are areas of electronic services, including electronic learning. With their efficient communication and information capabilities, these portals are capable of realizing novel learning concepts such as structuralism, active and cooperative learning. The present paper endeavors to discuss the latest understanding, theories and concepts regarding E-learning portals and to review the issues and steps that should be considered in designin...

  5. Preduodenal portal vein: its surgical significance.

    Science.gov (United States)

    Makey, D A; Bowen, J C

    1978-11-01

    Preduodenal portal vein is a rare anatomical variant which may be one of many anomalies in the neonate with duodenal "atresia." Preduodenal portal vein also may be an occasional finding in an adult undergoing biliary, gastric, or pancreatic surgery. Awareness and recognition of the anomaly are essential for the avoidance of injury during such operations. We report here a symptomless patient whose preduodenal portal vein was discovered at cholecystectomy.

  6. A nationwide Dutch study regarding treatment portals for elective neck irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Van Dieren, E B [Integraal Kankercentrum, Rotterdam (Netherlands); Nowak, P J.C.M.; Van Soernsen de Koste, J.R.; Van Est, H; Heijmen, B J.M.; Levendag, P C

    1995-12-01

    The variation in treatment portals for elective radiotherapy of the neck, and the three-dimensional dosimetric consequences of this variation was assessed. Therefore, 16 experienced radiation oncologists from all major head and neck cooperative groups in the Netherlands (n=11) were asked to define RT-portals on a lateral and/or AP simulation film, for (routine) elective neck irradiation for a T2 tumor of the mobile tongue and a T3 tumor of the supraglottic larynx. Treatment portals were compared and evaluated using a three-dimensional treatment planning system and CT data with contoured critical structures and target volume. The CT-defined clinical target volume was mutually agreed upon by ENT-surgeons and radiation oncologists. Large differences were seen in treated volume (a factor of five). In addition, due to the variation in the cranial boundary of the RT-portals, the estimated NTCP varied considerably (0-50%). Moreover, several of the RT-portals did not adequately cover the CT-defined target volume. Even amongst experienced head and neck radiation oncologists, little agreement was observed with respect to treatment technique and size of the treatment portals in case of elective neck irradiation. This results in a considerable variation in treated volume. As a consequence, a large difference exists in the anticipated probability of normal tissue complication, and possibly in tumor control probability. Therefore, a definition of target volume and, consequently, a standardization of elective neck portals in mandatory. This is even more important if the primary tumor and clinically node-negative neck are to be treated by 3D conformal RT using multiple CT-slices for target delineation and positioning of BEV blocks in order to spare the normal tissue function with maximum tumor control probability.

  7. A nationwide Dutch study regarding treatment portals for elective neck irradiation

    International Nuclear Information System (INIS)

    Van Dieren, E.B.; Nowak, P.J.C.M.; Van Soernsen de Koste, J.R.; Van Est, H.; Heijmen, B.J.M.; Levendag, P.C.

    1995-01-01

    The variation in treatment portals for elective radiotherapy of the neck, and the three-dimensional dosimetric consequences of this variation was assessed. Therefore, 16 experienced radiation oncologists from all major head and neck cooperative groups in the Netherlands (n=11) were asked to define RT-portals on a lateral and/or AP simulation film, for (routine) elective neck irradiation for a T2 tumor of the mobile tongue and a T3 tumor of the supraglottic larynx. Treatment portals were compared and evaluated using a three-dimensional treatment planning system and CT data with contoured critical structures and target volume. The CT-defined clinical target volume was mutually agreed upon by ENT-surgeons and radiation oncologists. Large differences were seen in treated volume (a factor of five). In addition, due to the variation in the cranial boundary of the RT-portals, the estimated NTCP varied considerably (0-50%). Moreover, several of the RT-portals did not adequately cover the CT-defined target volume. Even amongst experienced head and neck radiation oncologists, little agreement was observed with respect to treatment technique and size of the treatment portals in case of elective neck irradiation. This results in a considerable variation in treated volume. As a consequence, a large difference exists in the anticipated probability of normal tissue complication, and possibly in tumor control probability. Therefore, a definition of target volume and, consequently, a standardization of elective neck portals in mandatory. This is even more important if the primary tumor and clinically node-negative neck are to be treated by 3D conformal RT using multiple CT-slices for target delineation and positioning of BEV blocks in order to spare the normal tissue function with maximum tumor control probability

  8. Web-based Service Portal in Healthcare

    Science.gov (United States)

    Silhavy, Petr; Silhavy, Radek; Prokopova, Zdenka

    Information delivery is one the most important task in healthcare. The growing sector of electronic healthcare has an important impact on the information delivery. There are two basic approaches towards information delivering. The first is web portal and second is touch-screen terminal. The aim of this paper is to investigate the web-based service portal. The most important advantage of web-based portal in the field of healthcare is an independent access for patients. This paper deals with the conditions and frameworks for healthcare portals

  9. A user-oriented model for global enterprise portal design

    NARCIS (Netherlands)

    Feng, X.; Ehrenhard, Michel Léon; Hicks, Jeff; Maathuis, Stephanus Johannes; Maathuis, S.J.; Hou, Y.

    2010-01-01

    Enterprise portals collect and synthesise information from various systems to deliver personalised and highly relevant information to users. Enterprise portals' design and applications are widely discussed in the literature; however, the implications of portal design in a global networked

  10. Patient portals - An online tool for your health

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000880.htm Patient portals - an online tool for your health To ... is private and secure. What is in a Patient Portal? With a patient portal, you can: Make ...

  11. Portal Web 2.0

    OpenAIRE

    Barba Hidalgo, José Manuel

    2008-01-01

    El tema que es tracta en aquest projecte gira al voltant del concepte Web 2.0. Després d’una introducció on es comenten les principals característiques que defineixen el conjunt d’aplicacions agrupades al voltant d’aquesta filosofia, s’analitzen diferents entorns de desenvolupament d’aplicacions Web, amb l’objectiu de crear un portal que segueixi els principis Web 2.0. El resultat de l’estudi presenta a Ruby on Rails com un ferm candidat, això fa que es procedeixi a estudiar aq...

  12. Portal web para comunicaciones seguras

    OpenAIRE

    Jurado Villalobos, Rodrigo

    2015-01-01

    Proyecto teórico-práctico de investigación, enfocado a obtener un mayor conocimiento del funcionamiento de los protocolos y funciones de seguridad criptógrafica así como explorar las limitaciones y buscar nuevas vías de implementar la seguridad de las comunicaciones a través del desarrollo de una aplicación que dé uso en un entorno “real” de estos protocolos de seguridad. Dicha aplicación consistirá en un portal web de mensajería entre usuarios que empleará sistemas criptográficos tanto en el...

  13. Doppler US evaluation of the hypertensive portal system

    International Nuclear Information System (INIS)

    Needleman, L.; Kurtz, A.B.; Bezzi, M.; Rifkin, M.D.; Pasto, M.E.; Pennell, R.G.; Baltarowich, O.H.; Goldberg, B.B.

    1986-01-01

    In patients with known portal hypertension, pulsed Doppler US was used for qualitative and directional evaluation of flow in the portal venous system and collateral vessels. Most patients had normal hepatopetal flow. Doppler US revealed the following abnormal blood flow patterns: hepatofugal portal flow, bidirectional portal flow, intrahepatic portal shunting, flow in portasystemic collaterals, and hepatic vein obstruction. Doppler US can provide important clinical information in the evaluation of portal hypertension

  14. Portal in the power sector - it is vision or reality?

    International Nuclear Information System (INIS)

    Hornak, L.

    2004-01-01

    The goal of the presentation is to introduce the portal solutions, to describe the types, characteristic features and abilities of the portal and to define required attributes of the portal in the power segment. The author will try to answer the questions whether such portal exists at the present time, what is needed in order to implement the portal and how to do the portal maintenance and management

  15. Level-set segmentation of pulmonary nodules in megavolt electronic portal images using a CT prior

    International Nuclear Information System (INIS)

    Schildkraut, J. S.; Prosser, N.; Savakis, A.; Gomez, J.; Nazareth, D.; Singh, A. K.; Malhotra, H. K.

    2010-01-01

    Purpose: Pulmonary nodules present unique problems during radiation treatment due to nodule position uncertainty that is caused by respiration. The radiation field has to be enlarged to account for nodule motion during treatment. The purpose of this work is to provide a method of locating a pulmonary nodule in a megavolt portal image that can be used to reduce the internal target volume (ITV) during radiation therapy. A reduction in the ITV would result in a decrease in radiation toxicity to healthy tissue. Methods: Eight patients with nonsmall cell lung cancer were used in this study. CT scans that include the pulmonary nodule were captured with a GE Healthcare LightSpeed RT 16 scanner. Megavolt portal images were acquired with a Varian Trilogy unit equipped with an AS1000 electronic portal imaging device. The nodule localization method uses grayscale morphological filtering and level-set segmentation with a prior. The treatment-time portion of the algorithm is implemented on a graphical processing unit. Results: The method was retrospectively tested on eight cases that include a total of 151 megavolt portal image frames. The method reduced the nodule position uncertainty by an average of 40% for seven out of the eight cases. The treatment phase portion of the method has a subsecond execution time that makes it suitable for near-real-time nodule localization. Conclusions: A method was developed to localize a pulmonary nodule in a megavolt portal image. The method uses the characteristics of the nodule in a prior CT scan to enhance the nodule in the portal image and to identify the nodule region by level-set segmentation. In a retrospective study, the method reduced the nodule position uncertainty by an average of 40% for seven out of the eight cases studied.

  16. Front-end electronics for the Muon Portal project

    Energy Technology Data Exchange (ETDEWEB)

    Garozzo, S.; Marano, D.; Bonanno, G.; Grillo, A.; Romeo, G.; Timpanaro, M.C. [INAF, Osservatorio Astrofisico di Catania, Via S. Sofia 78, I-95123 Catania (Italy); Lo Presti, D.; Riggi, F.; Russo, V.; Bonanno, D.; La Rocca, P.; Longhitano, F.; Bongiovanni, D.G. [Università di Catania, Dipartimento di Fisica e Astronomia, and INFN, Sezione di Catania, Via S. Sofia 64, I-95123 Catania (Italy); Fallica, G.; Valvo, G. [ST-Microelectronics, Stradale V Primosole 50, Catania (Italy)

    2016-10-11

    The Muon Portal Project was born as a joint initiative between Italian research and industrial partners, aimed at the construction of a real-size working detector prototype to inspect the content of traveling containers by means of secondary cosmic-ray muon radiation and recognize potentially dangerous hidden materials. The tomographic image is obtained by reconstructing the incoming and outgoing muon trajectories when crossing the inspected volume, employing two tracker planes located above and below the container under inspection. In this paper, the design and development of the front-end electronics of the Muon Portal detector is presented, with particular emphasis being devoted to the photo-sensor devices detecting the scintillation light and to the read-out circuitry which is in charge of processing and digitizing the analog pulse signals. In addition, the remote control system, mechanical housing, and thermal cooling system of all structural blocks of the Muon Portal tracker are also discussed, demonstrating the effectiveness and functionality of the adopted design.

  17. Testing of portal monitors for personnel contamination control

    International Nuclear Information System (INIS)

    Johnson, L.O.; Gupta, V.P.; Stevenson, R.L.; Stalker, A.C.; Baker, K.R.; Littleton, M.L.; Rich, B.L.

    1983-04-01

    This is a report of an INPO-funded evaluation of state-of-the-art portal monitors used to detect personnel contamination. The project developed techniques and procedures to evaluate the performance and sensitivity of the portal monitors which provided data for intercomparison. An additional accomplishment was development of a methodology to assist manufacturers and users to optimize the monitor settings, and to provide technical basis for the eventual use of fixed monitors to replace frisking for contamination control. The monitors tested utilize thin-window gas-flow proportional counters sensitive to beta and gamma radiation. Various tests were performed: (1) background count rate and the statistical variability, (2) detector efficiency at different distances, (3) moving source sensitivity for various size sources and speeds, and (4) false alarm rates at different background levels. A model has been developed for the moving source measurements to compare the experimental data, and to test whether it is possible to adequately model the behavior of a portal monitor response to a moving source. The model results with the actual test results are compared

  18. Portal Hypertension in Patients with Liver Cirrhosis: Diagnostic Accuracy of Spleen Stiffness.

    Science.gov (United States)

    Takuma, Yoshitaka; Nouso, Kazuhiro; Morimoto, Youichi; Tomokuni, Junko; Sahara, Akiko; Takabatake, Hiroyuki; Matsueda, Kazuhiro; Yamamoto, Hiroshi

    2016-05-01

    To evaluate the accuracy of spleen stiffness (SS) and liver stiffness (LS) measured by using acoustic radiation force impulse imaging in the diagnosis of portal hypertension in patients with liver cirrhosis, with the hepatic venous pressure gradient (HVPG) as a reference standard. Institutional review board approval and informed consent were obtained for this prospective single-center study. From February 2012 to August 2013, 60 patients with liver cirrhosis (mean age, 70.8 years; age range, 34-88 years; 34 men, 26 women) with HVPG, LS, and SS measurements and gastrointestinal endoscopy and laboratory data were included if they met the following criteria: no recent episodes of gastrointestinal bleeding, no history of splenectomy, no history of partial splenic embolization, no history of β-blocker therapy, and absence of portal thrombosis. The efficacy of the parameters for the evaluation of portal hypertension was analyzed by using the Spearman rank-order correlation coefficient and receiver operating characteristic (ROC) curve analysis. The correlation coefficient between SS and HVPG (r = 0.876) was significantly better than that between LS and HVPG (r = 0.609, P portal hypertension (HVPG ≥ 10 mm Hg), severe portal hypertension (HVPG ≥ 12 mm Hg), esophageal varices (EVs), and high-risk EVs were significantly higher (0.943, 0.963, 0.937, and 0.955, respectively) than those of LS, spleen diameter, platelet count, and platelet count to spleen diameter ratio (P portal hypertension, severe portal hypertension, EVs, and high-risk EVs (negative likelihood ratios, 0.051, 0.056, 0.054, and 0.074, respectively). SS is reliable and has better diagnostic performance than LS for identifying portal hypertension in liver cirrhosis. (©) RSNA, 2015 Online supplemental material is available for this article.

  19. Factors Affecting Faculty Web Portal Usability

    Science.gov (United States)

    Bringula, Rex P.; Basa, Roselle S.

    2011-01-01

    The study investigated the factors that might significantly affect web portal usability. Results of the study were intended to serve as inputs for faculty web portal development of the University of the East-Manila. Descriptive statistics utilized questionnaire data from 82 faculty members. The data showed that most of the respondents were…

  20. Portal circulation aneurysms: two case reviews

    International Nuclear Information System (INIS)

    Perret, W. L.; Silva, A de.; Elzarka, A.; Schelleman, A.

    2007-01-01

    Venous aneurysms of the superior mesenteric vein and portal vein are an uncommon occurrence and often an incidental finding. They can also be associated with hepatocellular disease and portal hypertension. We present CT and ultrasound findings of these entities. The management of venous aneurysms is generally conservative with serial imaging

  1. Optimization of portal placement for endoscopic calcaneoplasty

    NARCIS (Netherlands)

    van Sterkenburg, Maayke N.; Groot, Minke; Sierevelt, Inger N.; Spennacchio, Pietro A.; Kerkhoffs, Gino M. M. J.; van Dijk, C. Niek

    2011-01-01

    The purpose of our study was to determine an anatomic landmark to help locate portals in endoscopic calcaneoplasty. The device for optimal portal placement (DOPP) was developed to measure the distance from the distal fibula tip to the calcaneus (DFC) in 28 volunteers to determine the location of the

  2. Percutaneous transhepatic portal vein stenting in a patient with benign non-transplant postoperative portal vein stenosis: A case report

    OpenAIRE

    Madhusudhan, KS; Agrawal, Nikhil; Srivastava, Deep N; Pal, Sujoy; Gupta, Arun K

    2013-01-01

    Extrahepatic portal vein stenosis is caused by a variety of benign and malignant diseases and results in development of symptoms due to portal hypertension. Benign post-surgical adhesions causing portal vein stenosis in non-transplant population is an uncommon etiology of portal hypertension. Endovascular treatment of such patients with angioplasty and stenting is uncommonly reported in literature. We report a case of portal hypertension caused by benign postoperative portal vein fibrosis, su...

  3. Isocurvature constraints on portal couplings

    Energy Technology Data Exchange (ETDEWEB)

    Kainulainen, Kimmo; Nurmi, Sami; Vaskonen, Ville [Department of Physics, University of Jyväskylä, P.O.Box 35 (YFL), FI-40014 University of Jyväskylä (Finland); Tenkanen, Tommi; Tuominen, Kimmo, E-mail: kimmo.kainulainen@jyu.fi, E-mail: sami.t.nurmi@jyu.fi, E-mail: tommi.tenkanen@helsinki.fi, E-mail: kimmo.i.tuominen@helsinki.fi, E-mail: ville.vaskonen@jyu.fi [Department of Physics, University of Helsinki P.O. Box 64, FI-00014, Helsinki (Finland)

    2016-06-01

    We consider portal models which are ultraweakly coupled with the Standard Model, and confront them with observational constraints on dark matter abundance and isocurvature perturbations. We assume the hidden sector to contain a real singlet scalar s and a sterile neutrino ψ coupled to s via a pseudoscalar Yukawa term. During inflation, a primordial condensate consisting of the singlet scalar s is generated, and its contribution to the isocurvature perturbations is imprinted onto the dark matter abundance. We compute the total dark matter abundance including the contributions from condensate decay and nonthermal production from the Standard Model sector. We then use the Planck limit on isocurvature perturbations to derive a novel constraint connecting dark matter mass and the singlet self coupling with the scale of inflation: m {sub DM}/GeV ∼< 0.2λ{sub s}{sup 3/8} ( H {sub *}/10{sup 11} GeV){sup −3/2}. This constraint is relevant in most portal models ultraweakly coupled with the Standard Model and containing light singlet scalar fields.

  4. Ultrasonography for Noninvasive Assessment of Portal Hypertension.

    Science.gov (United States)

    Maruyama, Hitoshi; Yokosuka, Osamu

    2017-07-15

    Portal hypertension is a major pathophysiology in patients with cirrhosis. Portal pressure is the gold standard to evaluate the severity of portal hypertension, and radiological intervention is the only procedure for pressure measurement. Ultrasound (US) is a simple and noninvasive imaging modality available worldwide. B-mode imaging allows broad applications for patients to detect and characterize chronic liver diseases and focal hepatic lesions. The Doppler technique offers real-time observation of blood flow with qualitative and quantitative assessments, and the application of microbubble-based contrast agents has improved the detectability of peripheral blood flow. In addition, elastography for the liver and spleen covers a wider field beyond the original purpose of fibrosis assessment. These developments enhance the practical use of US in the evaluation of portal hemodynamic abnormalities. This article reviews the recent progress of US in the assessment of portal hypertension.

  5. Idiopathic noncirrhotic portal hypertension: current perspectives.

    Science.gov (United States)

    Riggio, Oliviero; Gioia, Stefania; Pentassuglio, Ilaria; Nicoletti, Valeria; Valente, Michele; d'Amati, Giulia

    2016-01-01

    The term idiopathic noncirrhotic portal hypertension (INCPH) has been recently proposed to replace terms, such as hepatoportal sclerosis, idiopathic portal hypertension, incomplete septal cirrhosis, and nodular regenerative hyperplasia, used to describe patients with a hepatic presinusoidal cause of portal hypertension of unknown etiology, characterized by features of portal hypertension (esophageal varices, nonmalignant ascites, porto-venous collaterals), splenomegaly, patent portal, and hepatic veins and no clinical and histological signs of cirrhosis. Physicians should learn to look for this condition in a number of clinical settings, including cryptogenic cirrhosis, a disease known to be associated with INCPH, drug administration, and even chronic alterations in liver function tests. Once INCPH is clinically suspected, liver histology becomes mandatory for the correct diagnosis. However, pathologists should be familiar with the histological features of INCPH, especially in cases in which histology is not only requested to exclude liver cirrhosis.

  6. Enterprise Information Management with Plone Portals

    Directory of Open Access Journals (Sweden)

    Marcello Peixoto Bax

    2009-05-01

    Full Text Available The article shows that it is possible to implement a corporate portal using open source software, in an integrated manner with the proprietary MS Windows environment. As it is the real scenario in the vast majority of businesses and organizations today, a portal that meets these specific requirements is highly representative, mainly because MS Windows integration in the client environment (not in the server is not trivial for an open source portal. The paper shows that, by deploying a portal in this context the company considerably moves forward regarding information management. To show this, the article focuses on the key positive aspects arising from the deployment of a intranet / extranet portal in that context, i.e., MS Windows integration; editing with MS Office or other similar applications; shared editing control (with check-in and check-out; universal web access; and the use of metadata and workflow.

  7. SU-E-J-15: Automatically Detect Patient Treatment Position and Orientation in KV Portal Images

    Energy Technology Data Exchange (ETDEWEB)

    Qiu, J [Washington University in St Louis, Taian, Shandong (China); Yang, D [Washington University School of Medicine, St Louis, MO (United States)

    2015-06-15

    Purpose: In the course of radiation therapy, the complex information processing workflow will Result in potential errors, such as incorrect or inaccurate patient setups. With automatic image check and patient identification, such errors could be effectively reduced. For this purpose, we developed a simple and rapid image processing method, to automatically detect the patient position and orientation in 2D portal images, so to allow automatic check of positions and orientations for patient daily RT treatments. Methods: Based on the principle of portal image formation, a set of whole body DRR images were reconstructed from multiple whole body CT volume datasets, and fused together to be used as the matching template. To identify the patient setup position and orientation shown in a 2D portal image, the 2D portal image was preprocessed (contrast enhancement, down-sampling and couch table detection), then matched to the template image so to identify the laterality (left or right), position, orientation and treatment site. Results: Five day’s clinical qualified portal images were gathered randomly, then were processed by the automatic detection and matching method without any additional information. The detection results were visually checked by physicists. 182 images were correct detection in a total of 200kV portal images. The correct rate was 91%. Conclusion: The proposed method can detect patient setup and orientation quickly and automatically. It only requires the image intensity information in KV portal images. This method can be useful in the framework of Electronic Chart Check (ECCK) to reduce the potential errors in workflow of radiation therapy and so to improve patient safety. In addition, the auto-detection results, as the patient treatment site position and patient orientation, could be useful to guide the sequential image processing procedures, e.g. verification of patient daily setup accuracy. This work was partially supported by research grant from

  8. SU-E-J-15: Automatically Detect Patient Treatment Position and Orientation in KV Portal Images

    International Nuclear Information System (INIS)

    Qiu, J; Yang, D

    2015-01-01

    Purpose: In the course of radiation therapy, the complex information processing workflow will Result in potential errors, such as incorrect or inaccurate patient setups. With automatic image check and patient identification, such errors could be effectively reduced. For this purpose, we developed a simple and rapid image processing method, to automatically detect the patient position and orientation in 2D portal images, so to allow automatic check of positions and orientations for patient daily RT treatments. Methods: Based on the principle of portal image formation, a set of whole body DRR images were reconstructed from multiple whole body CT volume datasets, and fused together to be used as the matching template. To identify the patient setup position and orientation shown in a 2D portal image, the 2D portal image was preprocessed (contrast enhancement, down-sampling and couch table detection), then matched to the template image so to identify the laterality (left or right), position, orientation and treatment site. Results: Five day’s clinical qualified portal images were gathered randomly, then were processed by the automatic detection and matching method without any additional information. The detection results were visually checked by physicists. 182 images were correct detection in a total of 200kV portal images. The correct rate was 91%. Conclusion: The proposed method can detect patient setup and orientation quickly and automatically. It only requires the image intensity information in KV portal images. This method can be useful in the framework of Electronic Chart Check (ECCK) to reduce the potential errors in workflow of radiation therapy and so to improve patient safety. In addition, the auto-detection results, as the patient treatment site position and patient orientation, could be useful to guide the sequential image processing procedures, e.g. verification of patient daily setup accuracy. This work was partially supported by research grant from

  9. Web portal on environmental sciences "ATMOS''

    Directory of Open Access Journals (Sweden)

    E. P. Gordov

    2006-01-01

    Full Text Available The developed under INTAS grant web portal ATMOS (http://atmos.iao.ru and http://atmos.scert.ru makes available to the international research community, environmental managers, and the interested public, a bilingual information source for the domain of Atmospheric Physics and Chemistry, and the related application domain of air quality assessment and management. It offers access to integrated thematic information, experimental data, analytical tools and models, case studies, and related information and educational resources compiled, structured, and edited by the partners into a coherent and consistent thematic information resource. While offering the usual components of a thematic site such as link collections, user group registration, discussion forum, news section etc., the site is distinguished by its scientific information services and tools: on-line models and analytical tools, and data collections and case studies together with tutorial material. The portal is organized as a set of interrelated scientific sites, which addressed basic branches of Atmospheric Sciences and Climate Modeling as well as the applied domains of Air Quality Assessment and Management, Modeling, and Environmental Impact Assessment. Each scientific site is open for external access information-computational system realized by means of Internet technologies. The main basic science topics are devoted to Atmospheric Chemistry, Atmospheric Spectroscopy and Radiation, Atmospheric Aerosols, Atmospheric Dynamics and Atmospheric Models, including climate models. The portal ATMOS reflects current tendency of Environmental Sciences transformation into exact (quantitative sciences and is quite effective example of modern Information Technologies and Environmental Sciences integration. It makes the portal both an auxiliary instrument to support interdisciplinary projects of regional environment and extensive educational resource in this important domain.

  10. Time Series Evaluation of Portal Monitor Data

    International Nuclear Information System (INIS)

    Robinson, Sean M.; Bender, Sarah E.; Lopresti, Charles A.; Woodring, Mitchell L.

    2008-01-01

    Radiation portal monitors screen cargo and personal vehicle traffic at international border crossings to detect and interdict illicit sources which may be present in the commerce stream. One difficulty faced by RPM systems is the prospect of false alarms, or undesired alarms due to background fluctuation, or Naturally-Occurring Radioactive Material (NORM) sources in the commerce stream. In general, NORM alarms represent a significant fraction of the nuisance alarms at international border crossings, particularly with Polyvinyl-Toluene (PVT) RPM detectors, which have only very weak spectral differentiation capability. With PVT detectors, the majority of detected photon events fall within the Compton continuum of the material, allowing for very little spectral information to be preserved (1). Previous work has shown that these detectors can be used for limited spectroscopy, utilizing around 8 spectral bins to further differentiate some NORM and other nuisance sources (2). NaI based systems achieve much more detailed spectral resolution from each measurement of a source, but still combine all measurements over a vehicle's occupancy in order to arrive at a spectrum to be analyzed

  11. Customizable scientific web portal for fusion research

    International Nuclear Information System (INIS)

    Abla, G.; Kim, E.N.; Schissel, D.P.; Flanagan, S.M.

    2010-01-01

    Web browsers have become a major application interface for participating in scientific experiments such as those in magnetic fusion. The recent advances in web technologies motivated the deployment of interactive web applications with rich features. In the scientific world, web applications have been deployed in portal environments. When used in a scientific research environment, such as fusion experiments, web portals can present diverse sources of information in a unified interface. However, the design and development of a scientific web portal has its own challenges. One such challenge is that a web portal needs to be fast and interactive despite the high volume of information and number of tools it presents. Another challenge is that the visual output of the web portal must not be overwhelming to the end users, despite the high volume of data generated by fusion experiments. Therefore, the applications and information should be customizable depending on the needs of end users. In order to meet these challenges, the design and implementation of a web portal needs to support high interactivity and user customization. A web portal has been designed to support the experimental activities of DIII-D researchers worldwide by providing multiple services, such as real-time experiment status monitoring, diagnostic data access and interactive data visualization. The web portal also supports interactive collaborations by providing a collaborative logbook, shared visualization and online instant messaging services. The portal's design utilizes the multi-tier software architecture and has been implemented utilizing web 2.0 technologies, such as AJAX, Django, and Memcached, to develop a highly interactive and customizable user interface. It offers a customizable interface with personalized page layouts and list of services, which allows users to create a unique, personalized working environment to fit their own needs and interests. This paper describes the software

  12. Customizable scientific web portal for fusion research

    Energy Technology Data Exchange (ETDEWEB)

    Abla, G., E-mail: abla@fusion.gat.co [General Atomics, P.O. Box 85608, San Diego, CA (United States); Kim, E.N.; Schissel, D.P.; Flanagan, S.M. [General Atomics, P.O. Box 85608, San Diego, CA (United States)

    2010-07-15

    Web browsers have become a major application interface for participating in scientific experiments such as those in magnetic fusion. The recent advances in web technologies motivated the deployment of interactive web applications with rich features. In the scientific world, web applications have been deployed in portal environments. When used in a scientific research environment, such as fusion experiments, web portals can present diverse sources of information in a unified interface. However, the design and development of a scientific web portal has its own challenges. One such challenge is that a web portal needs to be fast and interactive despite the high volume of information and number of tools it presents. Another challenge is that the visual output of the web portal must not be overwhelming to the end users, despite the high volume of data generated by fusion experiments. Therefore, the applications and information should be customizable depending on the needs of end users. In order to meet these challenges, the design and implementation of a web portal needs to support high interactivity and user customization. A web portal has been designed to support the experimental activities of DIII-D researchers worldwide by providing multiple services, such as real-time experiment status monitoring, diagnostic data access and interactive data visualization. The web portal also supports interactive collaborations by providing a collaborative logbook, shared visualization and online instant messaging services. The portal's design utilizes the multi-tier software architecture and has been implemented utilizing web 2.0 technologies, such as AJAX, Django, and Memcached, to develop a highly interactive and customizable user interface. It offers a customizable interface with personalized page layouts and list of services, which allows users to create a unique, personalized working environment to fit their own needs and interests. This paper describes the software

  13. Customizable Scientific Web Portal for Fusion Research

    Energy Technology Data Exchange (ETDEWEB)

    Abla, G; Kim, E; Schissel, D; Flannagan, S [General Atomics, San Diego (United States)

    2009-07-01

    The Web browser has become one of the major application interfaces for remotely participating in magnetic fusion experiments. Recently in other areas, web portals have begun to be deployed. These portals are used to present very diverse sources of information in a unified way. While a web portal has several benefits over other software interfaces, such as providing single point of access for multiple computational services, and eliminating the need for client software installation, the design and development of a web portal has unique challenges. One of the challenges is that a web portal needs to be fast and interactive despite a high volume of tools and information that it presents. Another challenge is the visual output on the web portal often is overwhelming due to the high volume of data generated by complex scientific instruments and experiments; therefore the applications and information should be customizable depending on the needs of users. An appropriate software architecture and web technologies can meet these problems. A web-portal has been designed to support the experimental activities of DIII-D researchers worldwide. It utilizes a multi-tier software architecture, and web 2.0 technologies, such as AJAX, Django, and Memcached, to develop a highly interactive and customizable user interface. It offers a customizable interface with personalized page layouts and list of services for users to select. The users can create a unique personalized working environment to fit their own needs and interests. Customizable services are: real-time experiment status monitoring, diagnostic data access, interactive data visualization. The web-portal also supports interactive collaborations by providing collaborative logbook, shared visualization and online instant message services. Furthermore, the web portal will provide a mechanism to allow users to create their own applications on the web portal as well as bridging capabilities to external applications such as

  14. Customisable Scientific Web Portal for Fusion Research

    Energy Technology Data Exchange (ETDEWEB)

    Abla, G; Kim, E; Schissel, D; Flannagan, S [General Atomics, San Diego (United States)

    2009-07-01

    The Web browser has become one of the major application interfaces for remotely participating in magnetic fusion. Web portals are used to present very diverse sources of information in a unified way. While a web portal has several benefits over other software interfaces, such as providing single point of access for multiple computational services, and eliminating the need for client software installation, the design and development of a web portal has unique challenges. One of the challenges is that a web portal needs to be fast and interactive despite a high volume of tools and information that it presents. Another challenge is the visual output on the web portal often is overwhelming due to the high volume of data generated by complex scientific instruments and experiments; therefore the applications and information should be customizable depending on the needs of users. An appropriate software architecture and web technologies can meet these problems. A web-portal has been designed to support the experimental activities of DIII-D researchers worldwide. It utilizes a multi-tier software architecture, and web 2.0 technologies, such as AJAX, Django, and Memcached, to develop a highly interactive and customizable user interface. It offers a customizable interface with personalized page layouts and list of services for users to select. Customizable services are: real-time experiment status monitoring, diagnostic data access, interactive data visualization. The web-portal also supports interactive collaborations by providing collaborative logbook, shared visualization and online instant message services. Furthermore, the web portal will provide a mechanism to allow users to create their own applications on the web portal as well as bridging capabilities to external applications such as Twitter and other social networks. In this series of slides, we describe the software architecture of this scientific web portal and our experiences in utilizing web 2.0 technologies. A

  15. PSUP: A Planetary SUrface Portal

    Science.gov (United States)

    Poulet, F.; Quantin-Nataf, C.; Ballans, H.; Dassas, K.; Audouard, J.; Carter, J.; Gondet, B.; Lozac'h, L.; Malapert, J.-C.; Marmo, C.; Riu, L.; Séjourné, A.

    2018-01-01

    The large size and complexity of planetary data acquired by spacecraft during the last two decades create a demand within the planetary community for access to the archives of raw and high level data and for the tools necessary to analyze these data. Among the different targets of the Solar System, Mars is unique as the combined datasets from the Viking, Mars Global Surveyor, Mars Odyssey, Mars Express and Mars Reconnaissance Orbiter missions provide a tremendous wealth of information that can be used to study the surface of Mars. The number and the size of the datasets require an information system to process, manage and distribute data. The Observatories of Paris Sud (OSUPS) and Lyon (OSUL) have developed a portal, called PSUP (Planetary SUrface Portal), for providing users with efficient and easy access to data products dedicated to the Martian surface. The objectives of the portal are: 1) to allow processing and downloading of data via a specific application called MarsSI (Martian surface data processing Information System); 2) to provide the visualization and merging of high level (image, spectral, and topographic) products and catalogs via a web-based user interface (MarsVisu), and 3) to distribute some of these specific high level data with an emphasis on products issued by the science teams of OSUPS and OSUL. As the MarsSI service is extensively described in a companion paper (Quantin-Nataf et al., companion paper, submitted to this special issue), the present paper focus on the general architecture and the functionalities of the web-based user interface MarsVisu. This service provides access to many data products for Mars: albedo, mineral and thermal inertia global maps from spectrometers; mosaics from imagers; image footprints and rasters from the MarsSI tool; high level specific products (defined as catalogs or vectors). MarsVisu can be used to quickly assess the visualized processed data and maps as well as identify areas that have not been mapped yet

  16. The feasible study of vasodilators in portal vein targeting infusion for treating portal hypertension

    International Nuclear Information System (INIS)

    Wu Hanping; Liang Huiming; Zheng Chuansheng; Feng Gansheng

    2002-01-01

    Objective: To find out the ideal portal vein tar getting injection routes for portal hypertension treatment. Methods: 28 cirrhotic rat models with portal hypertension induced by CCl 4 were divided into 4 groups: inferior caval vein injection group, portal vein injection group, hepatic artery injection group, spleen injection group. The changes in portal vein pressure (PVP), inferior caval vein pressure (ICVP), mean artery pressure (MAP) and heart rate (HR) were monitored before and after prazosin injection. Results: After intra-portal, intra-hepatic arterial or spleen injection of prazosin, larger decrease in PVP and lesser effects on MAP than intravenous injection had been induced. The effect on HR showed no difference among these four groups. Conclusions: Hepatic artery and spleen prazosin administration have the same advantages on treatment of portal hypertension as those of intra-portal infusion, that is the greater decrease on portal vein pressure, the lesser effects on systemic hemodynamics. Vasodilation drugs for hepatic artery infusion through percutaneous port catheter system by hepatic artery implantation would be an ideal method for portal hypertension treatment

  17. CERN & Society launches donation portal

    CERN Multimedia

    Cian O'Luanaigh

    2014-01-01

    The CERN & Society programme brings together projects in the areas of education and outreach, innovation and knowledge exchange, and culture and arts, that spread the CERN spirit of scientific curiosity for the inspiration and benefit of society. Today, CERN & Society is launching its "giving" website – a portal to allow donors to contribute to various projects and forge new relationships with CERN.   "The CERN & Society initiative in its embryonic form began almost three years ago, with the feeling that the laboratory could play a bigger role for the benefit of society," says Matteo Castoldi, Head of the CERN Development Office, who, with his team, is seeking supporters and ambassadors for the CERN & Society initiative. "The concept is not completely new – in some sense it is embedded in CERN’s DNA, as the laboratory helps society by creating knowledge and new technologies – but we would like to d...

  18. Portal hydatid with secondary cavernomatosis.

    Science.gov (United States)

    Rodríguez Sanz, Mª Belén; Roldán Cuena, Mª Del Mar; Blanco Álvarez, Carlos Alberto; Sánchez Jiménez, Raúl

    2017-03-01

    The hydatid cyst is a parasitic infection included within the category of zoonoses, in which there exists a direct or indirect relation with animals, particularly with dogs. We report a clinical case of a patient who has undergone surgery of hydatid cyst in the right hepatic lobe. Seven years later the patient presents hydatid cyst in portal vein with secondary cavernomatosis, which is a rare complication. There are few cases described in the literature. The symtomatology presented by hydatid cyst is variable and the diagnosis is made by ultrasonography, TC and/or RNM. The treatment of choice is the surgical removal of the cyst, prior to surgery Albendazol must be administered for 1-2 weeks and be maintained for 4 more weeks after surgery.

  19. BSD Portals for LINUX 2.0

    Science.gov (United States)

    McNab, A. David; woo, Alex (Technical Monitor)

    1999-01-01

    Portals, an experimental feature of 4.4BSD, extend the file system name space by exporting certain open () requests to a user-space daemon. A portal daemon is mounted into the file name space as if it were a standard file system. When the kernel resolves a pathname and encounters a portal mount point, the remainder of the path is passed to the portal daemon. Depending on the portal "pathname" and the daemon's configuration, some type of open (2) is performed. The resulting file descriptor is passed back to the kernel which eventually returns it to the user, to whom it appears that a "normal" open has occurred. A proxy portalfs file system is responsible for kernel interaction with the daemon. The overall effect is that the portal daemon performs an open (2) on behalf of the kernel, possibly hiding substantial complexity from the calling process. One particularly useful application is implementing a connection service that allows simple scripts to open network sockets. This paper describes the implementation of portals for LINUX 2.0.

  20. The Seed Proteome Web Portal

    Directory of Open Access Journals (Sweden)

    Marc eGalland

    2012-06-01

    Full Text Available The Seed Proteome Web Portal (SPWP; http://www.seedproteome.com/ gives access to information both on quantitative seed proteomic data and on seed-related protocols. Firstly, the SPWP provides access to the 475 different Arabidopsis seed proteins annotated from 2 dimensional electrophoresis (2DE maps. Quantitative data are available for each protein according to their accumulation profile during the germination process. These proteins can be retrieved either in list format or directly on scanned 2DE maps. These proteomic data reveal that 40% of seed proteins maintain a stable abundance over germination, up to radicle protrusion. During sensu stricto germination (24 h upon imbibition about 50% of the proteins display quantitative variations, exhibiting an increased abundance (35% or a decreasing abundance (15%. Moreover, during radicle protrusion (24 h to 48 h upon imbibition, 41% proteins display quantitative variations with an increased (23% or a decreasing abundance (18%. In addition, an analysis of the seed proteome revealed the importance of protein post-translational modifications as demonstrated by the poor correlation (r2 = 0.29 between the theoretical (predicted from Arabidopsis genome and the observed protein isoelectric points. Secondly, the SPWP is a relevant technical resource for protocols specifically dedicated to Arabidopsis seed proteome studies. Concerning 2D electrophoresis, the user can find efficient procedures for sample preparation, electrophoresis coupled with gel analysis and protein identification by mass spectrometry, which we have routinely used during the last 12 years. Particular applications such as the detection of oxidized proteins or de novo synthetized proteins radiolabeled by [35S]-methionine are also given in great details. Future developments of this portal will include proteomic data from studies such as dormancy release and protein turnover through de novo protein synthesis analyses during germination.

  1. Patient portals and broadband internet inequality.

    Science.gov (United States)

    Perzynski, Adam T; Roach, Mary Joan; Shick, Sarah; Callahan, Bill; Gunzler, Douglas; Cebul, Randall; Kaelber, David C; Huml, Anne; Thornton, John Daryl; Einstadter, Douglas

    2017-09-01

    Patient portals have shown potential for increasing health care quality and efficiency. Internet access and other factors influencing patient portal use could worsen health disparities. Observational study of adults with 1 or more visits to the outpatient clinics of an urban public health care system from 2012 to 2015. We used mixed effects logistic regression to evaluate the association between broadband internet access and (1) patient portal initiation (whether a patient logged in at least 1 time) and (2) messaging, controlling for demographic and neighborhood characteristics. There were 243 248 adults with 1 or more visits during 2012-2015 and 70 835 (29.1%) initiated portal use. Portal initiation was 34.1% for whites, 23.4% for blacks, and 23.8% for Hispanics, and was lower for Medicaid (26.5%), Medicare (23.4%), and uninsured patients (17.4%) than commercially insured patients (39.3%). In multivariate analysis, both initiation of portal use (odds ratio [OR] = 1.24 per quintile, 95% confidence interval [CI], 1.23-1.24, P  internet access. The majority of adults with outpatient visits to a large urban health care system did not use the patient portal, and initiation of use was lower for racial and ethnic minorities, persons of lower socioeconomic status, and those without neighborhood broadband internet access. These results suggest the emergence of a digital divide in patient portal use. Given the scale of investment in patient portals and other internet-dependent health information technologies, efforts are urgently needed to address this growing inequality. © The Author 2017. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  2. Benign hepatic portal venous gas following caustic ingestion

    International Nuclear Information System (INIS)

    Lewin, Maite; Tubiana, Jean-Michel; Pocard, Marc; Caplin, Scott; Parc, Rolland; Blain, Antoine

    2002-01-01

    Hepatic portal vein gas has been documented in numerous conditions and is traditionally regarded as a poor prognostic sign. There are, however, several reports of portal vein gas with a benign course. We report the first case of transient hepatic portal vein gas secondary to the ingestion of a caustic substance. The literature of hepatic portal vein gas in benign disease is reviewed. (orig.)

  3. Radionuclide splenoportography in patients with portal hypertension

    International Nuclear Information System (INIS)

    Kuriya, Kouji; Nagamachi, Shigeki; Hoshi, Hiroaki; Ohnishi, Takashi; Jinnouchi, Masashi; Futami, Sigemi; Yoshida, Akira; Watanabe, Katsuji

    1991-01-01

    Splenoportography using 99m Tc-pertechnetate was performed in 18 patients with portal hypertension. 99m Tc pertechnetate (370 MBq) was directly injected into the spleen. Co-lateral circulation of portal vein was observed in 13 of 18 patients (72%). L/H ratio was also calculated by the time activity curve of dynamic images. L/H ratio was significantly lower (p<0.05) in patients with colateral vessels and severe esophageal varix. Radionuclide splenography was an useful method for evaluating hemodynamics of portal vein. (author)

  4. Radiations

    International Nuclear Information System (INIS)

    Pujol Mora, J.

    1999-01-01

    The exposition to ionizing radiations is a constant fact in the life of the human being and its utilization as diagnostic and therapeutic method is generalized. However, it is notorious how as years go on, the fear to the ionizing radiation seems to persist too, and this fact is not limited to the common individual, but to the technical personnel and professional personnel that labors with them same. (S. Grainger) [es

  5. Radiation

    International Nuclear Information System (INIS)

    Davidson, J.H.

    1986-01-01

    The basic facts about radiation are explained, along with some simple and natural ways of combating its ill-effects, based on ancient healing wisdom as well as the latest biochemical and technological research. Details are also given of the diet that saved thousands of lives in Nagasaki after the Atomic bomb attack. Special comment is made on the use of radiation for food processing. (U.K.)

  6. Predictive model of portal venous system thrombosis in cirrhotic portal hypertensive patients after splenectomy

    OpenAIRE

    He, Shasha; He, Fangping

    2015-01-01

    Objective: This study is to investigate the risk factors of portal venous system thrombosis (PVT) in patients with cirrhotic portal hypertension after splenectomy and to establish a Logistic regression prediction model. Methods: A total of 119 patients with cirrhotic portal hypertension were enrolled. Their clinical data was retrospectively analyzed. They were divided into PVT group (n = 18) and non-PVT group (n = 101). One-way analysis and multivariate Logistic regression analysis were perfo...

  7. Comprehensive fluence model for absolute portal dose image prediction

    International Nuclear Information System (INIS)

    Chytyk, K.; McCurdy, B. M. C.

    2009-01-01

    Amorphous silicon (a-Si) electronic portal imaging devices (EPIDs) continue to be investigated as treatment verification tools, with a particular focus on intensity modulated radiation therapy (IMRT). This verification could be accomplished through a comparison of measured portal images to predicted portal dose images. A general fluence determination tailored to portal dose image prediction would be a great asset in order to model the complex modulation of IMRT. A proposed physics-based parameter fluence model was commissioned by matching predicted EPID images to corresponding measured EPID images of multileaf collimator (MLC) defined fields. The two-source fluence model was composed of a focal Gaussian and an extrafocal Gaussian-like source. Specific aspects of the MLC and secondary collimators were also modeled (e.g., jaw and MLC transmission factors, MLC rounded leaf tips, tongue and groove effect, interleaf leakage, and leaf offsets). Several unique aspects of the model were developed based on the results of detailed Monte Carlo simulations of the linear accelerator including (1) use of a non-Gaussian extrafocal fluence source function, (2) separate energy spectra used for focal and extrafocal fluence, and (3) different off-axis energy spectra softening used for focal and extrafocal fluences. The predicted energy fluence was then convolved with Monte Carlo generated, EPID-specific dose kernels to convert incident fluence to dose delivered to the EPID. Measured EPID data were obtained with an a-Si EPID for various MLC-defined fields (from 1x1 to 20x20 cm 2 ) over a range of source-to-detector distances. These measured profiles were used to determine the fluence model parameters in a process analogous to the commissioning of a treatment planning system. The resulting model was tested on 20 clinical IMRT plans, including ten prostate and ten oropharyngeal cases. The model predicted the open-field profiles within 2%, 2 mm, while a mean of 96.6% of pixels over all

  8. Macronodular hepatic tuberculosis associated with portal vein thrombosis and portal hypertension

    International Nuclear Information System (INIS)

    Venkatesh, S.K.; Tan, L.K.A.; Siew, E.P.Y.; Putti, T.C.

    2005-01-01

    Tuberculosis (TB) of the liver is usually associated with miliary spread. Macronodular TB of the liver is rare. A case of macronodular TB of the liver in a 31-year-old woman causing portal vein thrombosis and portal hypertension is presented. Ultrasound and CT appearances are described. There was coexistent ileo-caecal TB with extensive mesenteric and retroperitoneal lymphadenopathy. Macronodular TB should be considered in the differential diagnosis when a patient presents with multiple calcified masses in the liver with portal vein thrombosis and portal hypertension. Copyright (2005) Blackwell Science Pty Ltd

  9. Radiation

    International Nuclear Information System (INIS)

    Winther, J.F.; Ulbak, K.; Dreyer, L.; Pukkala, E.; Oesterlind, A.

    1997-01-01

    Exposure to solar and ionizing radiation increases the risk for cancer in humans. Some 5% of solar radiation is within the ultraviolet spectrum and may cause both malignant melanoma and non-melanocytic skin cancer; the latter is regarded as a benign disease and is accordingly not included in our estimation of avoidable cancers. Under the assumption that the rate of occurrence of malignant melanoma of the buttocks of both men and women and of the scalp of women would apply to all parts of the body in people completely unexposed to solar radiation, it was estimated that approximately 95% of all malignant melanomas arising in the Nordic populations around the year 2000 will be due to exposure to natural ultraviolet radiation, equivalent to an annual number of about 4700 cases, with 2100 in men and 2600 in women, or some 4% of all cancers notified. Exposure to ionizing radiation in the Nordic countries occurs at an average effective dose per capita per year of about 3 mSv (Iceland, 1.1 mSv) from natural sources, and about 1 mSv from man-made sources. While the natural sources are primarily radon in indoor air, natural radionuclides in food, cosmic radiation and gamma radiation from soil and building materials, the man-made sources are dominated by the diagnostic and therapeutic use of ionizing radiation. On the basis of measured levels of radon in Nordic dwellings and associated risk estimates for lung cancer derived from well-conducted epidemiological studies, we estimated that about 180 cases of lung cancer (1% of all lung cancer cases) per year could be avoided in the Nordic countries around the year 2000 if indoor exposure to radon were eliminated, and that an additional 720 cases (6%) could be avoided annually if either radon or tobacco smoking were eliminated. Similarly, it was estimated that the exposure of the Nordic populations to natural sources of ionizing radiation other than radon and to medical sources will each give rise to an annual total of 2120

  10. Analysis of Dynamic Characteristics of Portal Frame with Variable Section

    OpenAIRE

    Hao Jianing

    2016-01-01

    Combined with a portal frame design, by the use of finite element software ANSYS, the finite element model of single specimens of portal rigid frame and the overall portal rigid frame building are established. portal rigid frame’s beam and column is variable cross section. Through the modal analysis, comparative analysis of the frequency and vibration type of the radiolabeling specimens and finite element model of the whole, for the further development of variable cross-section portal rigid f...

  11. Decision-making models in the analysis of portal films: a clinical pilot study

    International Nuclear Information System (INIS)

    See, A.; Johansen, J.; Hamilton, C.; Bydder, S.A.; Hawkins, J.; Roff, M.; Denham, J.; Kron, T.

    2000-01-01

    Portal films continue to play an important role in the verification of radiotherapy treatment. There is still some discussion, however, as to what action should be taken after a port film has shown a radiation field deviation from the prescribed volume. It was the aim of the present pilot study to investigate the performance of three decision-making models ('Amsterdam', 'Quebec' and 'Newcastle') and an expert panel basing their decision on intuition rather than formal rules after portal film acquisition in a clinical setting. Portal films were acquired on every day during the first week of treatment for five head and neck and five prostate cancer patients (diagnostic phase). If required, the field position was modified according to our normal practice following the recommendation of the expert panel. In order to analyse the results of the models, however, additional port films were taken in the following 3 treatment weeks with the patient moved as required by the different models (intervention phase). The portal films were taken over 4 consecutive days, positioning the patient according to each of the different models on one day each. None of the models diagnosed a field misplacement in the head and neck patients, while the 'Amsterdam' and 'Quebec' models predicted a move in one prostate patient. The 'Newcastle' model, which is based on Hotelling's T 2 statistic, proved to be more sensitive and diagnosed a systematic displacement for three prostate patients. The intervention phase confirmed the diagnosis of the model, even if the three portal films taken with the patient position adjusted as required by the model proved to be insufficient to demonstrate an improvement. The 'Newcastle' model does not rely on assumptions about the random movement of patients and requires five portal films before a decision can be reached. This approach lends itself well to incorporation into electronic portal imaging 'packages', where repeated image acquisitions present no logistical

  12. Federal High End Computing (HEC) Information Portal

    Data.gov (United States)

    Networking and Information Technology Research and Development, Executive Office of the President — This portal provides information about opportunities to engage in U.S. Federal government high performance computing activities, including supercomputer use,...

  13. Autonomic dysfunction in cirrhosis and portal hypertension

    DEFF Research Database (Denmark)

    Dümcke, Christine Winkler; Møller, Søren

    2008-01-01

    Liver cirrhosis and portal hypertension are frequently associated with signs of circulatory dysfunction and peripheral polyneuropathy, which includes defects of the autonomic nervous system. Autonomic dysfunction, which is seen in both alcoholic and non-alcoholic liver cirrhosis and increases...

  14. Scintiphotosplenoportography in patients with portal hypertension

    International Nuclear Information System (INIS)

    Aijaz, A.

    1990-01-01

    Scintiphotosplenoportograpy (SSP) was performed in five normals and 25 patients with portal hypertension using Tc-99m tin colloid. 12 patients were cirrhotic and 13 had idiopathic portal hypertension (IPH). Analogue and fast frame dynamic studies were performed and subsequently processed. Intra hepatic shunt index in cirrhotics was significantly different from the IPH group. Extra hepatic shunt index, however, was not significantly different in the two groups but was related more to the severity of the disease process. Spleno hepatic and spleno cardiac transit times were significantly lower cirrhotics as compared to the IPH group. We conclude that SSP is a technically simple, rapid and a much less invasive method of visualizing the portal circulatory system and assessing the portal haemo dynamics. it also provides clinically important measure of shunted blood nd allows for the quantification of circulatory time from spleen to liver and heart. (author)

  15. [Emphysematous gastritis with concomitant portal venous air].

    Science.gov (United States)

    Jeong, Min Yeong; Kim, Jin Il; Kim, Jae Young; Kim, Hyun Ho; Jo, Ik Hyun; Seo, Jae Hyun; Kim, Il Kyu; Cheung, Dae Young

    2015-02-01

    Emphysematous gastritis is a rare form of gastritis caused by infection of the stomach wall by gas forming bacteria. It is a very rare condition that carries a high mortality rate. Portal venous gas shadow represents elevation of intestinal luminal pressure which manifests as emphysematous gastritis or gastric emphysema. Literature reviews show that the mortality rate is especially high when portal venous gas shadow is present on CT scan. Until recently, the treatment of emphysematous gastritis has been immediate surgical intervention. However, there is a recent trend of avoiding surgery because of the frequent occurrence of post-operative complications such as anastomosis leakage. In addition, aggressive surgical treatment has failed to show significant improvement in prognosis. Recently, the authors experienced a case of emphysematous gastritis accompanied by portal venous gas which was treated successfully by conservative treatment without immediate surgical intervention. Herein, we present a case of emphysematous gastritis with concomitant portal venous air along with literature review.

  16. [Association of biliary calculosis and portal cavernomatosis].

    Science.gov (United States)

    Crespi, C; De Giorgio, A M

    1992-08-01

    This paper reports the case of a woman, who underwent surgery because of cholelithiasis, with intraoperative finding of prehepatic portal hypertension from portal vein thrombosis ("portal cavernoma") with healthy liver, later confirmed by angiographic studies. This rare pathologic association carries a higher risk of major operative complications; therefore the Authors agree with the general belief that, for these cases, biliary tract surgery should be as simple and safe as possible. In the case of preoperative diagnosis of biliary disease associated with portal cavernoma, should a surgical approach on the biliary tract be required, we agree on the advisability of performing a shunting procedure before any kind of biliary surgery. In case of variceal bleeding endoscopic sclerotherapy will be the first choice; surgical procedures (shunting) should be seen as a second choice in case of rebleeding after sclerotherapy.

  17. The International Human Epigenome Consortium Data Portal.

    Science.gov (United States)

    Bujold, David; Morais, David Anderson de Lima; Gauthier, Carol; Côté, Catherine; Caron, Maxime; Kwan, Tony; Chen, Kuang Chung; Laperle, Jonathan; Markovits, Alexei Nordell; Pastinen, Tomi; Caron, Bryan; Veilleux, Alain; Jacques, Pierre-Étienne; Bourque, Guillaume

    2016-11-23

    The International Human Epigenome Consortium (IHEC) coordinates the production of reference epigenome maps through the characterization of the regulome, methylome, and transcriptome from a wide range of tissues and cell types. To define conventions ensuring the compatibility of datasets and establish an infrastructure enabling data integration, analysis, and sharing, we developed the IHEC Data Portal (http://epigenomesportal.ca/ihec). The portal provides access to >7,000 reference epigenomic datasets, generated from >600 tissues, which have been contributed by seven international consortia: ENCODE, NIH Roadmap, CEEHRC, Blueprint, DEEP, AMED-CREST, and KNIH. The portal enhances the utility of these reference maps by facilitating the discovery, visualization, analysis, download, and sharing of epigenomics data. The IHEC Data Portal is the official source to navigate through IHEC datasets and represents a strategy for unifying the distributed data produced by international research consortia. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  18. R2 Water Quality Portal Monitoring Stations

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Water Quality Data Portal (WQP) provides an easy way to access data stored in various large water quality databases. The WQP provides various input parameters on...

  19. Design and implementation of a software for the remote control and monitoring of radiation portals; Diseno e implementacion de un software para la gestion y monitorizacion remota de porticos de radiaciones

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, J.; Rica, P. de la; Vivas, A.; Caballero, M.; Baeza, A.

    2012-07-01

    This paper describes the main activities developed for the detection of ionizing radiation in each eco-park access and have knowledge in time of the radioactive contents which possess the containers to the entry of these facilities, to identify both locally and remotely the origin of radiological anomalies that occur and act accordingly to correct them.

  20. Evaluation of portal hypertension by MR portography

    International Nuclear Information System (INIS)

    Nagaoka, Shirou; Hagiwara, Masaru; Imanisi, Yosimasa

    1997-01-01

    Seventy-eight examinations of MR portography were totally performed in 24 controls and 33 patients with esophageal varices. Portal vein, SMV, hepatic vein, and IVC were entirely depicted in 21, 24, 22, and 24, respectively, of the 24 controls. As to intrahepatic upward branches of portal vein in the right lobe of the liver, the 4th branch was at least depicted in all of the 24. Although the portal vein trunk and SMV were entirely depicted in all of the 8 patients without treatment and liver dysfunction of Child A, there was no depiction of them in 1 of the 8 patients with liver dysfunction of Child B, and 1 of 5 patients with liver dysfunction of Child C. The 4th upward branch of portal vein in the right lobe of the liver was depicted in none of the 33 patients. Besides, none of the intrahepatic portal branches were depicted in 1 of 8 patients without treatment and liver dysfunction of Child B, and 1 of the 5 patients without treatment and liver dysfunction of Child C. There was a significant difference of depicted terminal upward branch of portal vein between the controls and patients without any treatment. In the patients without any significant difference of depicted terminal upward branch of portal vein was also present between Child's classification A and Child's classification B and C. Gastric coronary vein varices were detected by MR portography is 18 of 19 patients without treatment on the esophageal varices, and paraesophageal/esophageal varices were also depicted by MR portography in 13 of the 19. The collaterals were depicted by MR portography in all of the 6 patients with recurrent collaterals after Hassab's operation or splenectomy. MR portography was able to depict flow in trunk branches and collaterals of the portal vein system in a physiological state. (K.H.)

  1. Getting started with Citrix CloudPortal

    CERN Document Server

    U, Puthiyavan

    2013-01-01

    The book will follow a step-by-step, tutorial-based approach and show readers how to take advantage of Citrix CloudPortal's capabilities.This book is ideal for administrators and engineers new to the Citrix Cloud Solution CPSM, CPBM, and who are looking to get a good grounding in Citrix's new product. It's assumed that you will have some experience in the basics of cloud computing already. No prior knowledge of CloudPortal is expected.

  2. Evaluation of portal hypertension by MR portography

    Energy Technology Data Exchange (ETDEWEB)

    Nagaoka, Shirou; Hagiwara, Masaru; Imanisi, Yosimasa [St. Marianna Univ., Kawasaki, Kanagawa (Japan). School of Medicine

    1997-02-01

    Seventy-eight examinations of MR portography were totally performed in 24 controls and 33 patients with esophageal varices. Portal vein, SMV, hepatic vein, and IVC were entirely depicted in 21, 24, 22, and 24, respectively, of the 24 controls. As to intrahepatic upward branches of portal vein in the right lobe of the liver, the 4th branch was at least depicted in all of the 24. Although the portal vein trunk and SMV were entirely depicted in all of the 8 patients without treatment and liver dysfunction of Child A, there was no depiction of them in 1 of the 8 patients with liver dysfunction of Child B, and 1 of 5 patients with liver dysfunction of Child C. The 4th upward branch of portal vein in the right lobe of the liver was depicted in none of the 33 patients. Besides, none of the intrahepatic portal branches were depicted in 1 of 8 patients without treatment and liver dysfunction of Child B, and 1 of the 5 patients without treatment and liver dysfunction of Child C. There was a significant difference of depicted terminal upward branch of portal vein between the controls and patients without any treatment. In the patients without any significant difference of depicted terminal upward branch of portal vein was also present between Child`s classification A and Child`s classification B and C. Gastric coronary vein varices were detected by MR portography is 18 of 19 patients without treatment on the esophageal varices, and paraesophageal/esophageal varices were also depicted by MR portography in 13 of the 19. The collaterals were depicted by MR portography in all of the 6 patients with recurrent collaterals after Hassab`s operation or splenectomy. MR portography was able to depict flow in trunk branches and collaterals of the portal vein system in a physiological state. (K.H.)

  3. Portal de empleo JobFinder.com

    OpenAIRE

    Cozar Campoy, Javier

    2012-01-01

    Con este proyecto se pretende crear un portal web para la búsqueda de empleo. Las empresas inscritas en el sistema pueden publicar diferentes ofertas de trabajo y del mismo modo los usuarios registrados pueden inscribirse en éstas. Amb aquest projecte es pretén crear un portal web per a la cerca de feina. Les empreses inscrites en el sistema poden publicar diferents ofertes de feina i de la mateixa manera els usuaris registrats poden inscriure's en aquestes.

  4. Idiopathic Noncirrhotic Portal Hypertension: An Appraisal

    Science.gov (United States)

    Lee, Hwajeong; Rehman, Aseeb Ur; Fiel, M. Isabel

    2016-01-01

    Idiopathic noncirrhotic portal hypertension is a poorly defined clinical condition of unknown etiology. Patients present with signs and symptoms of portal hypertension without evidence of cirrhosis. The disease course appears to be indolent and benign with an overall better outcome than cirrhosis, as long as the complications of portal hypertension are properly managed. This condition has been recognized in different parts of the world in diverse ethnic groups with variable risk factors, resulting in numerous terminologies and lack of standardized diagnostic criteria. Therefore, although the diagnosis of idiopathic noncirrhotic portal hypertension requires clinical exclusion of other conditions that can cause portal hypertension and histopathologic confirmation, this entity is under-recognized clinically as well as pathologically. Recent studies have demonstrated that variable histopathologic entities with different terms likely represent a histologic spectrum of a single entity of which obliterative portal venopathy might be an underlying pathogenesis. This perception calls for standardization of the nomenclature and formulation of widely accepted diagnostic criteria, which will facilitate easier recognition of this disorder and will highlight awareness of this entity. PMID:26563701

  5. Management of Portal Hypertension After Liver Transplantation.

    Science.gov (United States)

    Korda, D; Deák, P Á; Kiss, G; Gerlei, Z; Kóbori, L; Görög, D; Fehérvári, I; Piros, L; Máthé, Z; Doros, A

    2017-09-01

    Post-transplantation portal hypertension has severe complications, such as esophageal varix bleeding, therapy refractory ascites, extreme splenomegaly, and graft dysfunction. The aim of our study was to analyze the effectiveness of the therapeutic strategies and how to visualize the procedure. A retrospective study involving liver transplantation patients from the Semmelweis University Department of Transplantation and Surgery was performed between 2005 and 2015. The prevalence, etiology, and leading complications of the condition were determined. The applied interventions' effects on the patients' ascites volume, splenic volume, and the occurrence of variceal bleeding were determined. Mean portal blood flow velocity and congestion index values were calculated using Doppler ultrasonography. The prevalence of post-transplantation portal hypertension requiring intervention was 2.8%. The most common etiology of the disease was portal anastomotic stenosis. The most common complications were esophageal varix bleeding and therapy refractory ascites. The patients' ascites volume decreased significantly (2923.3 ± 1893.2 mL vs. 423.3 ± 634.3 mL; P portal hypertension. After the interventions, these parameters shifted towards the physiologic ranges. The interventions performed in our clinic were effective in most cases. The patients' ascites volume, splenic volume, and the prevalence of variceal bleeding decreased after the treatment. Doppler ultrasonography has proved to be a valuable imaging modality in the diagnosis and the follow-up of post-transplantation portal hypertension. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Dose patient verification during treatment using an amorphous silicon electronic portal imaging device in radiotherapy

    International Nuclear Information System (INIS)

    Berger, Lucie

    2006-01-01

    Today, amorphous silicon electronic portal imaging devices (aSi EPID) are currently used to check the accuracy of patient positioning. However, they are not use for dose reconstruction yet and more investigations are required to allow the use of an aSi EPID for routine dosimetric verification. The aim of this work is first to study the dosimetric characteristics of the EPID available at the Institut Curie and then, to check patient dose during treatment using these EPID. First, performance optimization of the Varian aS500 EPID system is studied. Then, a quality assurance system is set up in order to certify the image quality on a daily basis. An additional study on the dosimetric performance of the aS500 EPID is monitored to assess operational stability for dosimetry applications. Electronic portal imaging device is also a useful tool to improve IMRT quality control. The validation and the quality assurance of a portal dose image prediction system for IMRT pre-treatment quality control are performed. All dynamic IMRT fields are verified in clinical routine with the new method based on portal dosimetry. Finally, a new formalism for in vivo dosimetry using transit dose measured with EPID is developed and validated. The absolute dose measurement issue using aSi EPID is described and the midplane dose determination using in vivo dose measurements in combination with portal imaging is used with 3D-conformal-radiation therapy. (author) [fr

  7. Treatment portals for elective radiotherapy of the neck: an inventory in The Netherlands

    International Nuclear Information System (INIS)

    Nowak, Peter; Dieren, Erik van; Soernsen de Koste, John van; Est, Henry van der; Heijmen, Ben; Levendag, Peter

    1997-01-01

    Purpose: To assess the variation in and the three-dimensional dosimetric consequences of treatment portals for elective neck irradiation. Materials and methods: Radiation oncologists (n = 16) from all major Head and Neck Co-operative Groups in The Netherlands (n = 11) were asked to delineate treatment portals on a lateral and an anterior simulation film in case of elective neck irradiation for a T3N0 tumour of the supraglottic larynx and a T2N0 tumour of the mobile tongue. In addition, they had to define their target, i.e. which parts of the neck nodal regions they would choose to irradiate electively for these particular tumour sites. Subsequently, treatment portals were compared and evaluated using CT-data and a 3-dimensional (3D) treatment planning system. Results: Significant variations were found in the shapes and sizes of the applied treatment techniques and portals. Also, among radiation oncologists who elected to irradiate the same lymph node regions, a significant variation in the delineated treatment portals was observed. As a consequence, substantial variations in treated volumes and in calculated normal tissue complication probabilities (NTCPs) for the parotid- and submandibular glands were observed. Conclusion: For the tumour sites studied there appears to be a lack of standardisation in the areas of the neck to be irradiated electively. The observed differences may have consequences for the ultimate failure rate and particularly with regard to the side effects, e.g. the degree of xerostomia. It is argued that in the near future a more precise three-dimensional definition on CT of the lymph node regions in the neck might allow for a better standardisation of the treatment portals and, in addition, for the development and application of conformal radiotherapy techniques for optimal sparing of the critical normal tissues (e.g. parotid- and submandibular glands) with maximum tumour control probability

  8. Search Engine For Ebook Portal

    Directory of Open Access Journals (Sweden)

    Prashant Kanade

    2017-05-01

    Full Text Available The purpose of this paper is to establish the textual analytics involved in developing a search engine for an ebook portal. We have extracted our dataset from Project Gutenberg using a robot harvester. Textual Analytics is used for efficient search retrieval. The entire dataset is represented using Vector Space Model where each document is a vector in the vector space. Further for computational purposes we represent our dataset in the form of a Term Frequency- Inverse Document Frequency tf-idf matrix. The first step involves obtaining the most coherent sequence of words of the search query entered. The entered query is processed using Front End algorithms this includes-Spell Checker Text Segmentation and Language Modeling. Back End processing includes Similarity Modeling Clustering Indexing and Retrieval. The relationship between documents and words is established using cosine similarity measured between the documents and words in Vector Space. Clustering performed is used to suggest books that are similar to the search query entered by the user. Lastly the Lucene Based Elasticsearch engine is used for indexing on the documents. This allows faster retrieval of data. Elasticsearch returns a dictionary and creates a tf-idf matrix. The processed query is compared with the dictionary obtained and tf-idf matrix is used to calculate the score for each match to give most relevant result.

  9. MR and angiography: Evaluation of the hemodynamics of portal hypertension

    International Nuclear Information System (INIS)

    Torres, W.E.; Gaylord, G.M.; Whitmire, L.; Chuang, V.P.; Bernardino, M.E.

    1986-01-01

    Forty-two MR imaging examinations and angiographic procedures in 38 patients with portal hypertension were compared for how well the images depicted portal perfusion and direction of flow, portal vein thrombosis, and the presence and type of shunt. Thirty-three MR imaging studies indicated grade I or II portal flow. In 29 cases portal flow was grade I or II by angiography; in the remaining cases the flow was grade IV. In a total of eight cases portal flow was grade IV by angiography, but none appeared to be grade IV on MR imaging. Both MR imaging and angiography detected portal vein thrombosis (41 of 42 cases). MR imaging and angiography agreed as to whether a shunt was present or absent, and patent or occluded (41 of 42 cases). Currently, MR imaging is an unsatisfactory modality by which to grade portal flow. MR imaging does depict portal vein thrombosis well, and can be used to determine patency of surgical shunts

  10. Applications of portals in the energetic sector; Aplicaciones de portales en el sector energetico

    Energy Technology Data Exchange (ETDEWEB)

    Santos Dominguez, Martin; Arroyo Figueroa, Gustavo [Instituto de Investigaciones Electricas, Temixco, Morelos (Mexico)

    2000-07-01

    An operative portal joins the applications, contents and services of the company in a single page of Intranet such way that promises to change deeply the information technology in the next years. The corporative portals will change what people visualize in the screen of their computer at the beginning of every working day. Unlike seeing the network (Web) only with pages of language of hypertext bearing (HTML), the corporative portal acts as a gate between Internet and the private networks. This article presents a general vision of the benefits of the corporative portals, the existing technologies and the potential markets. [Spanish] Un portal operativo une las aplicaciones, contenidos y servicios de la empresa en una sola pagina de Intranet, de tal forma que promete cambiar, profundamente la tecnologia de la informacion en los proximos anos. Los portales corporativos cambiaran lo que la gente visualiza en la pantalla de su computadora al comienzo de cada dia de trabajo. A diferencia de ver la red (Web) solo con paginas de lenguaje de marcacion de hipertexto (HTML), el portal corporativo actua como compuerta entre Internet y las redes privadas. Este articulo presenta una vision general de los beneficios de los portales corporativos, las tecnologias y los mercados potenciales existentes.

  11. An Approach for harmonizing European Water Portals

    Science.gov (United States)

    Pesquer, Lluís; Stasch, Christoph; Masó, Joan; Jirka, Simon; Domingo, Xavier; Guitart, Francesc; Turner, Thomas; Hinderk Jürrens, Eike

    2017-04-01

    A number of European funded research projects is developing novel solutions for water monitoring, modeling and management. To generate innovations in the water sector, third parties from industry and the public sector need to take up the solutions and bring them into the market. A variety of portals exists to support this move into the market. Examples on the European level are the EIP Water Online Marketplace(1), the WaterInnEU Marketplace(2), the WISE RTD Water knowledge portal(3), the WIDEST- ICT for Water Observatory(4) or the SWITCH-ON Virtual Product Market and Virtual Water-Science Laboratory(5). Further innovation portals and initiatives exist on the national or regional level, for example, the Denmark knows water platform6 or the Dutch water alliance(7). However, the different portals often cover the same projects, the same products and the same services. Since they are technically separated and have their own data models and databases, people need to duplicate information and maintain it at several endpoints. This requires additional efforts and hinders the interoperable exchange between these portals and tools using the underlying data. In this work, we provide an overview on the existing portals and present an approach for harmonizing and integrating common information that is provided across different portals. The approach aims to integrate the common in formation in a common database utilizing existing vocabularies, where possible. An Application Programming Interface allows access the information in a machine-readable way and utilizing the information in other applications beyond description and discovery purposes. (1) http://www.eip-water.eu/my-market-place (2) https://marketplace.waterinneu.org (3) http://www.wise-rtd.info/ (4) http://iwo.widest.eu (5) http://www.switch-on-vwsl.eu/ (6) http://www.rethinkwater.dk/ (7) http://wateralliance.nl/

  12. Next Gen One Portal Usability Evaluation

    Science.gov (United States)

    Cross, E. V., III; Perera, J. S.; Hanson, A. M.; English, K.; Vu, L.; Amonette, W.

    2018-01-01

    Each exercise device on the International Space Station (ISS) has a unique, customized software system interface with unique layouts / hierarchy, and operational principles that require significant crew training. Furthermore, the software programs are not adaptable and provide no real-time feedback or motivation to enhance the exercise experience and/or prevent injuries. Additionally, the graphical user interfaces (GUI) of these systems present information through multiple layers resulting in difficulty navigating to the desired screens and functions. These limitations of current exercise device GUI's lead to increased crew time spent on initiating, loading, performing exercises, logging data and exiting the system. To address these limitations a Next Generation One Portal (NextGen One Portal) Crew Countermeasure System (CMS) was developed, which utilizes the latest industry guidelines in GUI designs to provide an intuitive ease of use approach (i.e., 80% of the functionality gained within 5-10 minutes of initial use without/limited formal training required). This is accomplished by providing a consistent interface using common software to reduce crew training, increase efficiency & user satisfaction while also reducing development & maintenance costs. Results from the usability evaluations showed the NextGen One Portal UI having greater efficiency, learnability, memorability, usability and overall user experience than the current Advanced Resistive Exercise Device (ARED) UI used by astronauts on ISS. Specifically, the design of the One-Portal UI as an app interface similar to those found on the Apple and Google's App Store, assisted many of the participants in grasping the concepts of the interface with minimum training. Although the NextGen One-Portal UI was shown to be an overall better interface, observations by the test facilitators noted specific exercise tasks appeared to have a significant impact on the NextGen One-Portal UI efficiency. Future updates to

  13. Portal imaging practice patterns of children's oncology group institutions: Dosimetric assessment and recommendations for minimizing unnecessary exposure

    International Nuclear Information System (INIS)

    Olch, Arthur J.; Geurts, Mark; Thomadsen, Bruce; Famiglietti, Robin; Chang, Eric L.

    2007-01-01

    Purpose: To determine and analyze the dosimetric consequences of current portal imaging practices for pediatric patients, and make specific recommendations for reducing exposure from portal imaging procedures. Methods and Materials: A survey was sent to approximately 250 Children's Oncology Group (COG) member institutions asking a series of questions about their portal imaging practices. Three case studies are presented with dosimetric analysis to illustrate the magnitude of unintended dose received by nontarget tissues using the most common techniques from the survey. Results: The vast majority of centers use double-exposure portal image techniques with a variety of open field margins. Only 17% of portal images were obtained during treatment, and for other imaging methods, few centers subtract monitor units from the treatment delivery. The number of monitor units used was nearly the same regardless of imager type, including electronic portal imaging devices. Eighty-six percent imaged all fields the first week and 17% imaged all fields every week. An additional 1,112 cm 3 of nontarget tissue received 1 Gy in one of the example cases. Eight new recommendations are made, which will lower nontarget radiation doses with minimal impact on treatment verification accuracy. Conclusion: Based on the survey, changes can be made in portal imaging practices that will lower nontarget doses. It is anticipated that treatment verification accuracy will be minimally affected. Specific recommendations made to decrease the imaging dose and help lower the rate of radiation-induced secondary cancers in children are proposed for inclusion in future COG protocols using radiation therapy

  14. The Sydney West Knowledge Portal: Evaluating the Growth of a Knowledge Portal to Support Translational Research.

    Science.gov (United States)

    Janssen, Anna; Robinson, Tracy Elizabeth; Provan, Pamela; Shaw, Tim

    2016-06-29

    The Sydney West Translational Cancer Research Centre is an organization funded to build capacity for translational research in cancer. Translational research is essential for ensuring the integration of best available evidence into practice and for improving patient outcomes. However, there is a low level of awareness regarding what it is and how to conduct it optimally. One solution to addressing this gap is the design and deployment of web-based knowledge portals to disseminate new knowledge and engage with and connect dispersed networks of researchers. A knowledge portal is an web-based platform for increasing knowledge dissemination and management in a specialized area. To measure the design and growth of an web-based knowledge portal for increasing individual awareness of translational research and to build organizational capacity for the delivery of translational research projects in cancer. An adaptive methodology was used to capture the design and growth of an web-based knowledge portal in cancer. This involved stakeholder consultations to inform initial design of the portal. Once the portal was live, site analytics were reviewed to evaluate member usage of the portal and to measure growth in membership. Knowledge portal membership grew consistently for the first 18 months after deployment, before leveling out. Analysis of site metrics revealed members were most likely to visit portal pages with community-generated content, particularly pages with a focus on translational research. This was closely followed by pages that disseminated educational material about translational research. Preliminary data from this study suggest that knowledge portals may be beneficial tools for translating new evidence and fostering an environment of communication and collaboration.

  15. The MISTRALS programme data portal

    Science.gov (United States)

    Fleury, Laurence; Brissebrat, Guillaume; Belmahfoud, Nizar; Boichard, Jean-Luc; Brosolo, Laetitia; Cloché, Sophie; Descloitres, Jacques; Ferré, Hélène; Focsa, Loredana; Labatut, Laurent; Mastrorillo, Laurence; Mière, Arnaud; Petit de la Villéon, Loïc; Ramage, Karim; Schmechtig, Catherine

    2014-05-01

    different file formats and data processing tools. The MISTRALS data portal - http://mistrals.sedoo.fr/ - has been designed and developed as a unified tool to share scientific data in spite of many sources of heterogeneity, and to foster collaboration between research communities. The metadata (data description) are standardized and comply with international standards (ISO 19115-19139; INSPIRE European Directive; Global Change Master Directory Thesaurus). A search tool allows to browse the catalogue by keyword or by multicriteria selection (location, period, physical property...) and to access data. Data sets managed by different data centres (ICARE, IPSL, SEDOO, CORIOLIS) are available through interoperability protocols (OPeNDAP, xml requests...) or archive synchronisation. At present the MISTRALS data portal allows to access more than 400 datasets and counts more than 500 registered users. The number of available datasets is increasing daily, due to the provision of campaign datasets (2012, 2013) by several projects. Every in situ data set is available in the native format, but the favorite data sets have been homogenized (property names, units, quality flags...) and inserted in a relational database, in order to enable more accurate data selection, and download of different datasets in a shared format. Every scientist is invited to make use of the different MISTRALS tools and data. Do not hesitate to browse the catalogue and fill the online registration form. Feel free to contact mistrals-contact@sedoo.fr for any question.

  16. The MISTRALS programme data portal

    Science.gov (United States)

    Brissebrat, Guillaume; Belmahfoud, Nizar; Cloché, Sophie; Darras, Sabine; Descloitres, Jacques; Drocourt, Yoann; Ferré, Hélène; Henriot, Nicolas; Ramage, Karim

    2017-04-01

    different file formats and data processing tools. The MISTRALS data portal - http://mistrals.sedoo.fr/ - has been designed and developed as a unified tool for sharing scientific data in spite of many sources of heterogeneity, and for fostering collaboration between research communities. The metadata (data description) are standardized and comply with international standards (ISO 19115-19139; INSPIRE European Directive; Global Change Master Directory Thesaurus). A search tool allows to browse the catalog by keyword or multicriteria selection (area, period, physical property...) and to access data. Every in situ dataset is available in the native format, but the most commonly used datasets have been homogenized (property names, units, quality flags...) and inserted in a relational database, in order to enable accurate data selection, and download in standard formats. At present the MISTRALS data portal enables to access about 650 datasets. It counts more than 675 registered users and about 100 data requests every month. The number of available datasets is increasing daily, due to the provision of campaign datasets by several projects. Every scientist is invited to browse the catalog, complete the online registration and use MISTRALS data. Feel free to contact mistrals-contact@sedoo.fr for any question.

  17. Calcification in the portal venous system demonstrated by computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hadar, H; Sommer, R

    1983-08-01

    The CT appearance of calcification in the portal venous system in a patient with chronic alcoholic cirrhosis is presented. Reported cases of radiologically detectable calcification in the portal system are rare, and most of them have been associated with longstanding portal hypertension. We presume that with CT this diagnosis will be made more frequently. In the presence of calcification in the portal venous system, portal vein thrombosis is highly probable. This information is of obvious importance to the surgeon contemplating a portal decompressive shunt procedure.

  18. Unexpected disappearance of portal cavernoma on long-term anticoagulation.

    Science.gov (United States)

    Silva-Junior, Gilberto; Turon, Fanny; Hernandez-Gea, Virginia; Darnell, Anna; García-Criado, Ángeles; García-Pagán, Juan Carlos

    2014-08-01

    Idiopathic non-cirrhotic portal hypertension is a rare disease of unknown etiology. Patients with idiopathic non-cirrhotic portal hypertension have an increased risk of developing portal vein thrombosis and this is especially prevalent when HIV is also present. We describe a unique case of a patient with idiopathic non-cirrhotic portal hypertension associated to HIV, who developed acute portal vein thrombosis that despite anticoagulation transformed in portal cavernoma and disappeared completely after five years of follow-up on continuous anticoagulation. Copyright © 2014 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

  19. Regional blood flows by the microsphere method: reproducibility in portal hypertensive rats and influence of a portal vein catheter

    International Nuclear Information System (INIS)

    Hadengue, A.; Lee, S.S.; Koshy, A.; Girod, C.; Lebrec, D.

    1988-01-01

    To determine the reproducibility of splanchnic blood flow measurements by the microsphere method in rats with portal hypertension and the effects of laparotomy with portal vein cannulation, eight groups of 10 rats were studied. Microspheres were labelled with 113 Sn or 141 Ce. Laparotomy with portal cannulation had no significant effect in sham-operated rats. In awake portal hypertensive rats, cardiac output and splanchnic blood flow were lower in portal vein cannulated rats compared with those of non-cannulated animals. In anesthetized portal hypertensive rats blood flows were unaffected by portal cannulation, but arterial pressure and heart rate were elevated. Anesthesia also decreased portal pressure in portal hypertensive rats. We conclude that the microsphere method remains reproducible in portal hypertensive rat models. Laparotomy with portal cannulation can alter systemic and splanchnic hemodynamics in portal hypertensive rats; these effects can also be changed during pentobarbital anesthesia. Regional blood flow measurements in portal hypertensive rats should be performed in animals without portal cannulation and preferably in the awake state

  20. Metabolic effects of portal vein sensing.

    Science.gov (United States)

    Mithieux, G

    2014-09-01

    The extrinsic gastrointestinal nerves are crucial in the sensing of nutrients and hormones and its translation in terms of control of food intake. Major macronutrients like glucose and protein are sensed by the extrinsic nerves located in the portal vein walls, which signal to the brain and account for the satiety phenomenon they promote. Glucose is sensed in the portal vein by neurons expressing the glucose receptor SGLT3, which activate the main regions of the brain involved in the control of food intake. Proteins indirectly act on food intake by inducing intestinal gluconeogenesis and its sensing by the portal glucose sensor. The mechanism involves a prior antagonism by peptides of the μ-opioid receptors present in the portal vein nervous system and a reflex arc with the brain inducing intestinal gluconeogenesis. In a comparable manner, short-chain fatty acids produced from soluble fibre act via intestinal gluconeogenesis to exert anti-obesity and anti-diabetic effects. In the case of propionate, the mechanism involves a prior activation of the free fatty acid receptor FFAR3 present in the portal nerves and a reflex arc initiating intestinal gluconeogenesis. © 2014 John Wiley & Sons Ltd.

  1. Percutaneous transhepatic portal vein stenting in a patient with benign non-transplant postoperative portal vein stenosis: A case report

    Directory of Open Access Journals (Sweden)

    KS Madhusudhan

    2013-01-01

    Full Text Available Extrahepatic portal vein stenosis is caused by a variety of benign and malignant diseases and results in development of symptoms due to portal hypertension. Benign post-surgical adhesions causing portal vein stenosis in non-transplant population is an uncommon etiology of portal hypertension. Endovascular treatment of such patients with angioplasty and stenting is uncommonly reported in literature. We report a case of portal hypertension caused by benign postoperative portal vein fibrosis, successfully treated by self-expandable metallic stent.

  2. Commissioning of Portal Dosimetry and characterization of an EPID

    International Nuclear Information System (INIS)

    Olbi, D.S.; Sales, C.P.; Nakandakari, M.V.N.

    2016-01-01

    The development of technologies compensator blocks, MLC, high dose rate accelerators, treatment planning systems, among others, permitted that new treatment techniques in radiotherapy were created. Such techniques have the capacity to modulate radiation beam fluency (IMRT, VMAT), or to deliver high doses in few fractions or unique fractions (SRS). Following the same tendency, quality control of planning became more complex. It is necessary to evaluate the fluency delivered by the accelerator. Its levels of does and its spatial distribution should co-occur with the fluency calculated by TPS. Acquisition of new detector devices in quality control of treatments is fundamental to apply techniques. Portal Vision is a device EPID has the capacity to operate either in image mode or dosimetry mode, with the allowance of Portal Dosimetry. To evaluated planning in IMRT, the device is irradiated using planning e, therefore, the fluency measured is compared with calculated fluency, through gamma analysis. The aim of this work was to perform tests of commissioning of this device. (author)

  3. Digital portal radiography in mantle-field irradiation

    International Nuclear Information System (INIS)

    Scheck, R.J.; Wendt, T.; Panzer, M.

    1991-01-01

    This paper evaluates the potential of digital luminescence radiography to improve image quality of portal films in mantle-field irradiation. Conventional and digital verification films of an anthropomorphic phantom and 20 patients treated for Hodgkin disease with mantle radiation therapy were obtained with high-energy photon beams. Both conventional films and storage phosphor screens were placed into a cassette with steel intensifier screens. Exposed storage phosphor screens were processed in a semiautomatic mode, with an optimized contrast curve with moderate edge enhancement, and printed as hard copies in a double-image output format. Images were evaluated according to contrast resolution, delineation of anatomic structures, and accuracy of field alignment. Digital portal radiographs were superior to conventional ones with regard to contrast resolution. Thus, they allowed quick and easy detection of relevant structures, although delineation of anatomic structures and field alignments were judged to be equivalent with both techniques. Shorter exposure times for digital images resulted in a reduction in motion artifacts

  4. Prediction of Liver Function by Using Magnetic Resonance-based Portal Venous Perfusion Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Cao Yue, E-mail: yuecao@umich.edu [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Department of Radiology, University of Michigan, Ann Arbor, Michigan (United States); Wang Hesheng [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Johnson, Timothy D. [Department of Biostatistics, University of Michigan, Ann Arbor, Michigan (United States); Pan, Charlie [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Hussain, Hero [Department of Radiology, University of Michigan, Ann Arbor, Michigan (United States); Balter, James M.; Normolle, Daniel; Ben-Josef, Edgar; Ten Haken, Randall K.; Lawrence, Theodore S.; Feng, Mary [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States)

    2013-01-01

    Purpose: To evaluate whether liver function can be assessed globally and spatially by using volumetric dynamic contrast-enhanced magnetic resonance imaging MRI (DCE-MRI) to potentially aid in adaptive treatment planning. Methods and Materials: Seventeen patients with intrahepatic cancer undergoing focal radiation therapy (RT) were enrolled in institution review board-approved prospective studies to obtain DCE-MRI (to measure regional perfusion) and indocyanine green (ICG) clearance rates (to measure overall liver function) prior to, during, and at 1 and 2 months after treatment. The volumetric distribution of portal venous perfusion in the whole liver was estimated for each scan. We assessed the correlation between mean portal venous perfusion in the nontumor volume of the liver and overall liver function measured by ICG before, during, and after RT. The dose response for regional portal venous perfusion to RT was determined using a linear mixed effects model. Results: There was a significant correlation between the ICG clearance rate and mean portal venous perfusion in the functioning liver parenchyma, suggesting that portal venous perfusion could be used as a surrogate for function. Reduction in regional venous perfusion 1 month after RT was predicted by the locally accumulated biologically corrected dose at the end of RT (P<.0007). Regional portal venous perfusion measured during RT was a significant predictor for regional venous perfusion assessed 1 month after RT (P<.00001). Global hypovenous perfusion pre-RT was observed in 4 patients (3 patients with hepatocellular carcinoma and cirrhosis), 3 of whom had recovered from hypoperfusion, except in the highest dose regions, post-RT. In addition, 3 patients who had normal perfusion pre-RT had marked hypervenous perfusion or reperfusion in low-dose regions post-RT. Conclusions: This study suggests that MR-based volumetric hepatic perfusion imaging may be a biomarker for spatial distribution of liver function, which

  5. Best Practices for Building Web Data Portals

    Science.gov (United States)

    Anderson, R. A.; Drew, L.

    2013-12-01

    With a data archive of more than 1.5 petabytes and a key role as the NASA Distributed Active Archive Center (DAAC) for synthetic aperture radar (SAR) data, the Alaska Satellite Facility (ASF) has an imperative to develop effective Web data portals. As part of continuous enhancement and expansion of its website, ASF recently created two data portals for distribution of SAR data: one for the archiving and distribution of NASA's MEaSUREs Wetlands project and one for newly digitally processed data from NASA's 1978 Seasat satellite. These case studies informed ASF's development of the following set of best practices for developing Web data portals. 1) Maintain well-organized, quality data. This is fundamental. If data are poorly organized or contain errors, credibility is lost and the data will not be used. 2) Match data to likely data uses. 3) Identify audiences in as much detail as possible. ASF DAAC's Seasat and Wetlands portals target three groups of users: a) scientists already familiar with ASF DAAC's SAR archive and our data download tool, Vertex; b) scientists not familiar with SAR or ASF, but who can use the data for their research of oceans, sea ice, volcanoes, land deformation and other Earth sciences; c) audiences wishing to learn more about SAR and its use in Earth sciences. 4) Identify the heaviest data uses and the terms scientists search for online when trying to find data for those uses. 5) Create search engine optimized (SEO) Web content that corresponds to those searches. Because search engines do not yet search raw data, so Web data portals must include content that ties the data to its likely uses. 6) Create Web designs that best serves data users (user centered design), not for how the organization views itself or its data. Usability testing was conducted for the ASF DAAC Wetlands portal to improve the user experience. 7) Use SEO tips and techniques. The ASF DAAC Seasat portal used numerous SEO techniques, including social media, blogging

  6. Radionuclide assessment of portal hypertension syndrome

    International Nuclear Information System (INIS)

    Aliev, M.A.; Khusain, Sh.K.; Alpeisova, Sh.T.

    2005-01-01

    This paper presents review of radionuclide studies for portal hypertension patients. Presented results showed that portal hypertension signs were revealed for the first group patients. The signs become apparent by splenomegaly and increase of colloid accumulation in it. Accumulation of the chemical in spleen was evidence of ingestion rate increase of reticuloendothelial system owing to its hyperplasia as well as liver phagocytic activity decrease due to pathological paren-chematous process and inter liver blockade. The most typical scintigraphic signs of portal hypertension were determined according chemical accumulation decreased in spleen and marrow sequentially. It is determined radionuclide method contributes to assessment of structural and functional aberrations character in liver and spleen for cirrhosis patients. (author)

  7. Perivesical varices and portal hypertension: imaging study

    International Nuclear Information System (INIS)

    Mallorquin Jimenez, F.; Medina Benitez, A.; Lopez Machado, E.; Pardo Moreno, M.D.; Garrido Moreno, C.; Pastor Rull, J.

    1995-01-01

    Nine patients with portal hypertension syndrome and Perivesical varices are studied retrospectively by means of imaging techniques including ultrasound, duplex Doppler, color Doppler, CT and angiography. All the patients presented portal thrombosis and thickening of the bladder wall. These collaterals either represent a shunting of hepato pedal flow or correspond to blood stasis associated with said syndrome. Ultrasound, whether involving duplex Doppler or color Doppler techniques, is highly useful to detect the presence of Perivesical varices which appear as tubular or rounded hypo echogenic areas in the bladder wall. Given the association of this entity with bladder wall thickening, it should be taken into account in any clinical situation involving said change, especially in patients with portal hypertension; moreover knowledge of its presence is of great importance when the possibility of creating shunts by means of interventional or surgical vascular procedures or other types of abdominal procedures are being considered because of the risk of bleeding. (Author)

  8. Configuring Mobile Commerce Portals for Business Success

    DEFF Research Database (Denmark)

    Dholakia, Nikhilesh; Rask, Morten

    2004-01-01

    -portals must attract and retain customers. Success in mobile portal markets will depend on dynamic strategies that blend elements of personalization, permission, and specification of content. This chapter reviews the key differences between traditional e-commerce and the emergent m-commerce. It reviews...... the core concepts of personalization, permission, and content specification as they apply to e-commerce and m-commerce. The chapter presents a framework for developing effective business strategies for developing and managing mobile portals. http://www.morten-rask.dk/2003c.htm......M-commerce entails transactions conducted via mobile telecommunications networks using communication, information, and payment devices such as mobile phones or palmtop units. Geographic positioning and location capabilities are also being added to such networks and devices. Rather than using...

  9. Building a Smart Portal for Astronomy

    Science.gov (United States)

    Derriere, S.; Boch, T.

    2011-07-01

    The development of a portal for accessing astronomical resources is not an easy task. The ever-increasing complexity of the data products can result in very complex user interfaces, requiring a lot of effort and learning from the user in order to perform searches. This is often a design choice, where the user must explicitly set many constraints, while the portal search logic remains simple. We investigated a different approach, where the query interface is kept as simple as possible (ideally, a simple text field, like for Google search), and the search logic is made much more complex to interpret the query in a relevant manner. We will present the implications of this approach in terms of interpretation and categorization of the query parameters (related to astronomical vocabularies), translation (mapping) of these concepts into the portal components metadata, identification of query schemes and use cases matching the input parameters, and delivery of query results to the user.

  10. Application of the smart portal in transportation

    International Nuclear Information System (INIS)

    Kercel, S.W.; Baylor, V.M.; Dress, W.B.; Hickerson, T.W.; Jatko, W.B.; Labaj, L.E.; Muhs, J.D.; Pack, R.M.

    1996-01-01

    Under a program sponsored by the Department of Energy, the Oak Ridge complex is developed a ''Portal-of-the-Future'', or ''smart portal''. This is a security portal for vehicular traffic which is intended to quickly detect explosives, hidden passengers, etc. It uses several technologies, including microwaves, weigh-in-motion, digital image processing, and electroacoustic wavelet-based heartbeat detection. A novel component of particular interest is the Enclosed Space Detection System (ESDS), which detects the presence of persons hiding in a vehicle. The system operates by detecting the presence of a human ballistocardiographic signature. Each time the heart beats, it generates a small but measurable shock wave that propagates through the body. The wave, whose graph is called a ballistocardiogram, is the mechanical analog of the electrocardiogram, which is routinely used for medical diagnosis. The wave is, in turn, coupled to any surface or object with which the body is in contact. If the body is located in an enclosed space, this will result in a measurable deflection of the surface of the enclosure. Independent testing has shown ESDS to be highly reliable. The technologies used in the smart portal operate in real time and allow vehicles to be checked through the portal in much less time than would be required for human inspection. Although not originally developed for commercial transportation, the smart portal has the potential to solve several transportation problems. It could relieve congestion at international highway border crossings by reducing the time required to inspect each vehicle while increasing the level of security. It can reduce highway congestion at the entrance of secure facilities such as prisons. Also, it could provide security at intermodal transfer points, such as airport parking lots and car ferry terminals

  11. Application of the smart portal in transportation

    Energy Technology Data Exchange (ETDEWEB)

    Kercel, S.W.; Baylor, V.M.; Dress, W.B.; Hickerson, T.W.; Jatko, W.B.; Labaj, L.E.; Muhs, J.D.; Pack, R.M.

    1996-12-31

    Under a program sponsored by the Department of Energy, the Oak Ridge complex is developed a ``Portal-of-the-Future``, or ``smart portal``. This is a security portal for vehicular traffic which is intended to quickly detect explosives, hidden passengers, etc. It uses several technologies, including microwaves, weigh-in-motion, digital image processing, and electroacoustic wavelet-based heartbeat detection. A novel component of particular interest is the Enclosed Space Detection System (ESDS), which detects the presence of persons hiding in a vehicle. The system operates by detecting the presence of a human ballistocardiographic signature. Each time the heart beats, it generates a small but measurable shock wave that propagates through the body. The wave, whose graph is called a ballistocardiogram, is the mechanical analog of the electrocardiogram, which is routinely used for medical diagnosis. The wave is, in turn, coupled to any surface or object with which the body is in contact. If the body is located in an enclosed space, this will result in a measurable deflection of the surface of the enclosure. Independent testing has shown ESDS to be highly reliable. The technologies used in the smart portal operate in real time and allow vehicles to be checked through the portal in much less time than would be required for human inspection. Although not originally developed for commercial transportation, the smart portal has the potential to solve several transportation problems. It could relieve congestion at international highway border crossings by reducing the time required to inspect each vehicle while increasing the level of security. It can reduce highway congestion at the entrance of secure facilities such as prisons. Also, it could provide security at intermodal transfer points, such as airport parking lots and car ferry terminals.

  12. Interactive monitoring portal for fusion simulations

    International Nuclear Information System (INIS)

    Abla, G.; Schissel, D.P.; Kim, E.N.; Flanagan, S.M.; Lee, X.

    2012-01-01

    Highlights: ► We designed a web-based monitoring system that tracks the status of fusion simulations. ► Our system is scalable to monitor the simulations running on distributed supercomputers and clusters located at multiple geographical locations. ► The monitoring portal provides a web-based interface for post-run analysis, such as visualizing the results, logging the user comments, and rating the simulation quality. ► Our system utilizes the open source software, such as Python, Django, MySQL, Apache, and MDSplus. - Abstract: The Center for Simulation of RF Wave Interactions with Magnetohydrodynamics (SWIM) Project is a proto-Fusion Simulation Program (FSP) whose goal is to study high-performance fusion plasmas and perform comprehensive simulations that are essential to the development of fusion. SWIM team members are geographically distributed and utilize distributed supercomputers for computational simulations. Due to the highly distributed computational work environment, the SWIM team has the difficulty of monitoring code runs and discovering historical runs. To alleviate this difficulty a web-based monitoring portal has been developed and deployed. The monitoring portal tracks the progress of simulations and automatically collects metadata in real-time. This capability helps scientists to effectively utilize precious computer resources. Furthermore, the portal provides a web-based interface for post-run analysis, such as visualizing the results, logging the user comments, and rating the simulation quality. The user interface provides rapid discovery capability via multi-field searching and sorting. The development of the monitoring portal used open source software, such as Python, Django, MySQL, and Apache. It uses MDSplus for data management, Memcached for data caches, and OpenID for single sign-on security. This paper describes the software architecture, related technologies and deployment experiences of the monitoring portal.

  13. Application of the smart portal in transportation

    Science.gov (United States)

    Kercel, Stephen W.; Baylor, Vivian M.; Dress, William B.; Hickerson, Tim W.; Jatko, William B.; Labaj, Leo E.; Muhs, Jeffrey D.; Pack, Richard M.

    1997-02-01

    Under a program sponsored by the Department of Energy, the Oak Ridge complex is developing a `Portal-of-the-Future', or `smart portal.' This is a security portal for vehicular traffic which is intended to quickly detect explosives, hidden passengers, etc. It uses several technologies, including microwaves, weigh-in-motion, digital image processing, and electroacoustic wavelet-based heartbeat detection. A novel component of particular interest is the Enclosed Space Detection System (ESDS), which detects the presence of persons hiding in a vehicle. The system operates by detecting the presence of a human ballistocardiographic signature. Each time the heart beats, it generates a small but measurable shock wave that propagates through the body. The wave, whose graph is called a ballistocardiogram, is the mechanical analog of the electrocardiograms, which is routinely used for medical diagnosis. The wave is, in turn, coupled to any surface or object with which the body is in contact. If the body is located in an enclosed space, this will result in a measurable deflection of the surface of the enclosure. Independent testing has shown ESDS to be highly reliable. The technologies used in the smart portal operate in real time and allow vehicles to be checked through the portal in much less time than would be required for human inspection. Although not originally developed for commercial transportation, the smart portal has the potential to solve several transportation problems. It could relieve congestion at international highway border crossings by reducing the time required to inspect each vehicle while increasing the level of security. It can reduce highway congestion at the entrance of secure facilities such as prisons. Also, it could provide security at intermodal transfer points, such as airport parking lots and car ferry terminals.

  14. Portal placement in elbow arthroscopy by novice surgeons: cadaver study.

    Science.gov (United States)

    Claessen, Femke M A P; Kachooei, Amir R; Kolovich, Gregory P; Buijze, Geert A; Oh, Luke S; van den Bekerom, Michel P J; Doornberg, Job N

    2017-07-01

    In this anatomical cadaver study, the distance between major nerves and ligaments at risk for injury and portal sites created by trainees was measured. Trainees, inexperienced in elbow arthroscopy, have received a didactic lecture and cadaver instruction prior to portal placement. The incidence of iatrogenic injury from novice portal placement was also determined. Anterolateral, direct lateral, and anteromedial arthroscopic portals were created in ten cadavers by ten inexperienced trainees in elbow arthroscopy. After creating each portal, the trajectory of the portal was marked with a guide pin. Subsequently, the cadavers were dissected and the distances between the guide pin in the anterolateral, direct lateral, and anteromedial portals and important ligaments and nerves were measured. The difference between the distance of the direct lateral portal and the posterior antebrachial cutaneous nerve (PABCN) (22 mm, p cadaver instruction session alone. Level of evidence V.

  15. Commissioning of Portal Dosimetry and characterization of an EPID; Comissionamento de Portal Dosimetry e caracterizacao de EPID

    Energy Technology Data Exchange (ETDEWEB)

    Olbi, D.S.; Sales, C.P. [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Medicina; Nakandakari, M.V.N., E-mail: diego.olbi@hc.fm.usp.br [Instituto do Cancer do Estado de Sao Paulo, SP (Brazil). Servico de Radioterapia

    2016-07-01

    The development of technologies compensator blocks, MLC, high dose rate accelerators, treatment planning systems, among others, permitted that new treatment techniques in radiotherapy were created. Such techniques have the capacity to modulate radiation beam fluency (IMRT, VMAT), or to deliver high doses in few fractions or unique fractions (SRS). Following the same tendency, quality control of planning became more complex. It is necessary to evaluate the fluency delivered by the accelerator. Its levels of does and its spatial distribution should co-occur with the fluency calculated by TPS. Acquisition of new detector devices in quality control of treatments is fundamental to apply techniques. Portal Vision is a device EPID has the capacity to operate either in image mode or dosimetry mode, with the allowance of Portal Dosimetry. To evaluated planning in IMRT, the device is irradiated using planning e, therefore, the fluency measured is compared with calculated fluency, through gamma analysis. The aim of this work was to perform tests of commissioning of this device. (author)

  16. R2 Water Quality Portal Monitoring Stations

    Science.gov (United States)

    The Water Quality Data Portal (WQP) provides an easy way to access data stored in various large water quality databases. The WQP provides various input parameters on the form including location, site, sampling, and date parameters to filter and customize the returned results. The The Water Quality Portal (WQP) is a cooperative service sponsored by the United States Geological Survey (USGS), the Environmental Protection Agency (EPA) and the National Water Quality Monitoring Council (NWQMC) that integrates publicly available water quality data from the USGS National Water Information System (NWIS) the EPA STOrage and RETrieval (STORET) Data Warehouse, and the USDA ARS Sustaining The Earth??s Watersheds - Agricultural Research Database System (STEWARDS).

  17. Implementation of a program of quality assurance of image in an imaging system of flat panel portal; Puesta en marcha de un programa de garantia de calidad de imagen en un sistema de imagen portal de panel plano

    Energy Technology Data Exchange (ETDEWEB)

    Gomez Barrado, A.; Sanchez Jimenez, E.; Benitez, J. A.; Sanchez-Reyes, A.

    2013-07-01

    (IGRT) image-guided radiation therapy is the one in which images are used to locate the area of treatment. Modern irradiation systems are equipped with different modalities for obtaining images, such as flat panel systems, systems conebeam, tomoimagen, etc. This paper describes the start-up and the experience of a quality assurance program based on a flat panel portal Imaging System. (Author)

  18. Duplication of the Portal Vein: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Won; Shin, Hyeong Cheol; Jou, Sung Shick; Han, Jong Kyu; Kim, Il Young [Soonchunhyang University Cheonan Hospital, Cheonan (Korea, Republic of)

    2009-12-15

    The duplication of the portal vein is an uncommon congenital anomaly. To date, only four cases have been reported in the medical literature. This anomaly can cause portal hypertension in pediatric patients. In addition, duplication of the portal vein has various patterns of connection with a splenic vein or mesenteric veins, and it can lie anterior or posterior to the duodenum. We report the MDCT findings of an adult patient with duplication of the portal vein that was found incidentally

  19. Feasibility of megavoltage portal CT using an electronic portal imaging device (EPID) and a multi-level scheme algebraic reconstruction technique (MLS-ART)

    International Nuclear Information System (INIS)

    Guan, Huaiqun; Zhu, Yunping

    1998-01-01

    Although electronic portal imaging devices (EPIDs) are efficient tools for radiation therapy verification, they only provide images of overlapped anatomic structures. We investigated using a fluorescent screen/CCD-based EPID, coupled with a novel multi-level scheme algebraic reconstruction technique (MLS-ART), for a feasibility study of portal computed tomography (CT) reconstructions. The CT images might be useful for radiation treatment planning and verification. We used an EPID, set it to work at the linear dynamic range and collimated 6 MV photons from a linear accelerator to a slit beam of 1 cm wide and 25 cm long. We performed scans under a total of ∼200 monitor units (MUs) for several phantoms in which we varied the number of projections and MUs per projection. The reconstructed images demonstrated that using the new MLS-ART technique megavoltage portal CT with a total of 200 MUs can achieve a contrast detectibility of ∼2.5% (object size 5mmx5mm) and a spatial resolution of 2.5 mm. (author)

  20. Assessment of the quality of educational portals

    Directory of Open Access Journals (Sweden)

    R. G. Bolbakov

    2017-01-01

    Full Text Available The article describes the results of theoretical and experimental studies on the evaluation of the quality of educational information placed on information and educational portals. The methodology allows you to compare not only portals, but also the results of training on exam scores and test scores. The methodological basis of the assessment is the cognitive approach and the negentropic approach. The article gives a comparison of entropy and negentropy. On the basis of comparison, the authors propose a negentropic approach to assessing the quality of educational resources obtained as a result of information retrieval. The search results are evaluated by cognitive and perpetual scores. Estimates are introduced into the entropy formula and converted to the formula of negentropy. The negentropic approach serves as the basis for calculating the statistical amount of information obtained as a result of information retrieval. The cognitive approach serves as a basis for assessing the qualitative characteristics of educational information, such as: visibility, perceptibility, interpretability. Open information portalsare the source of educational resources. The article shows that modern information portals are often clogged with unreliable or unnecessary information, which makes it difficult to find relevant educational information. In contrast to the widespread methods for one relevanceassess of the information retrieval, this article differentiates the notion of the relevance of the information retrieval. The article introduces three qualitatively different notions of relevance: formal, semantic and perpetual – relevance. The article introduces new additional characteristics of the quality of information search, the coefficient of cognition and the coefficient of perpetuation. These coefficients are introduced into the formula for estimating entropy and obtain the cognitive-entropy formula. As a result, a new method for assessing the content of

  1. Portal Hypertension Secondary to Spontaneous Arterio-Portal Venous Fistulas: Transcatheter Arterial Embolization with n-Butyl Cyanoacrylate and Microcoils

    International Nuclear Information System (INIS)

    Yamagami, Takuji; Nakamura, Toshiyuki; Nishimura, Tsunehiko

    2000-01-01

    We report a 73-year-old man with recurrent variceal bleeding due to portal hypertension caused by multiple intrahepatic arterio-portal venous fistulas, which were successfully occluded by embolization with n-butyl cyanoacrylate and micro-coils

  2. Base of tongue varices associated with portal hypertension

    OpenAIRE

    Jassar, P; Jaramillo, M; Nunez, D

    2000-01-01

    A symptomatic case of tongue base varices in a patient with portal hypertension secondary to liver cirrhosis is presented. There are no previously documented cases in the world literature. Oesophageal varices may not be the only source of expectorated blood in a patient with portal hypertension.


Keywords: portal hypertension; lingual; tongue; varicose vein

  3. User Needs of Digital Service Web Portals: A Case Study

    Science.gov (United States)

    Heo, Misook; Song, Jung-Sook; Seol, Moon-Won

    2013-01-01

    The authors examined the needs of digital information service web portal users. More specifically, the needs of Korean cultural portal users were examined as a case study. The conceptual framework of a web-based portal is that it is a complex, web-based service application with characteristics of information systems and service agents. In…

  4. Velocity Estimation of the Main Portal Vein with Transverse Oscillation

    DEFF Research Database (Denmark)

    Brandt, Andreas Hjelm; Hansen, Kristoffer Lindskov; Nielsen, Michael Bachmann

    2015-01-01

    This study evaluates if Transverse Oscillation (TO) can provide reliable and accurate peak velocity estimates of blood flow the main portal vein. TO was evaluated against the recommended and most widely used technique for portal flow estimation, Spectral Doppler Ultrasound (SDU). The main portal...

  5. Comparison of computer workstation with light box for detecting setup errors from portal images

    International Nuclear Information System (INIS)

    Boxwala, Aziz A.; Chaney, Edward L.; Fritsch, Daniel S.; Raghavan, Suraj; Coffey, Christopher S.; Major, Stacey A.; Muller, Keith E.

    1999-01-01

    Purpose: Observer studies were conducted to test the hypothesis that radiation oncologists using a computer workstation for portal image analysis can detect setup errors at least as accurately as when following standard clinical practice of inspecting portal films on a light box. Methods and Materials: In a controlled observer study, nine radiation oncologists used a computer workstation, called PortFolio, to detect setup errors in 40 realistic digitally reconstructed portal radiograph (DRPR) images. PortFolio is a prototype workstation for radiation oncologists to display and inspect digital portal images for setup errors. PortFolio includes tools for image enhancement; alignment of crosshairs, field edges, and anatomic structures on reference and acquired images; measurement of distances and angles; and viewing registered images superimposed on one another. The test DRPRs contained known in-plane translation or rotation errors in the placement of the fields over target regions in the pelvis and head. Test images used in the study were also printed on film for observers to view on a light box and interpret using standard clinical practice. The mean accuracy for error detection for each approach was measured and the results were compared using repeated measures analysis of variance (ANOVA) with the Geisser-Greenhouse test statistic. Results: The results indicate that radiation oncologists participating in this study could detect and quantify in-plane rotation and translation errors more accurately with PortFolio compared to standard clinical practice. Conclusions: Based on the results of this limited study, it is reasonable to conclude that workstations similar to PortFolio can be used efficaciously in clinical practice

  6. Implementation of a program of quality assurance of image in an imaging system of flat panel portal

    International Nuclear Information System (INIS)

    Gomez Barrado, A.; Sanchez Jimenez, E.; Benitez, J. A.; Sanchez-Reyes, A.

    2013-01-01

    (IGRT) image-guided radiation therapy is the one in which images are used to locate the area of treatment. Modern irradiation systems are equipped with different modalities for obtaining images, such as flat panel systems, systems conebeam, tomoimagen, etc. This paper describes the start-up and the experience of a quality assurance program based on a flat panel portal Imaging System. (Author)

  7. Overview of 3-year experience with large-scale electronic portal imaging device-based 3-dimensional transit dosimetry

    NARCIS (Netherlands)

    Mijnheer, Ben J.; González, Patrick; Olaciregui-Ruiz, Igor; Rozendaal, Roel A.; van Herk, Marcel; Mans, Anton

    2015-01-01

    To assess the usefulness of electronic portal imaging device (EPID)-based 3-dimensional (3D) transit dosimetry in a radiation therapy department by analyzing a large set of dose verification results. In our institution, routine in vivo dose verification of all treatments is performed by means of 3D

  8. Implementation of a Quality Control using portal imaging dynamic MLC; Implementacion de un programa de control de calidad de MLC dinamico mediante imagen portal

    Energy Technology Data Exchange (ETDEWEB)

    Sanz Freire, C. J.; Vazquez Galinanes, A.; Collado Chamorro, P. M.; Diaz Pascual, V.; Gomez Amez, J.; Sanchez Martinez, S.; Ossola Lentati, G. A

    2011-07-01

    The precision in the correct beam irradiation in the treatment of highly modulated Intensity Modulated Radiation Therapy (IMRT) depends largely on the characteristics and behavior of the multi leaf collimator (MLC). Quality control (QC) of this element is essential to ensure proper delivery of the beams calculated. It is important to know the absolute position of each sheet, the motion characteristics of each behavior and stability. Among the numerous methods for carrying out the QC MLC, the use of portal imaging is a practical and high resolution. This paper describes the development of a quality control program based dynamic MLC portal image, self-developed software that enables analysis and the results of two years experience following the implementation of IMRT treatments at our center. (Author)

  9. Analysis of patient setup accuracy using electronic portal imaging device

    International Nuclear Information System (INIS)

    Onogi, Yuzo; Aoki, Yukimasa; Nakagawa, Keiichi

    1996-01-01

    Radiation therapy is performed in many fractions, and accurate patient setup is very important. This is more significant nowadays because treatment planning and radiation therapy are more precisely performed. Electronic portal imaging devices and automatic image comparison algorithms let us analyze setup deviations quantitatively. With such in mind we developed a simple image comparison algorithm. Using 2459 electronic verification images (335 ports, 123 treatment sites) generated during the past three years at our institute, we evaluated the results of the algorithm, and analyzed setup deviations according to the area irradiated, use of a fixing device (shell), and arm position. Calculated setup deviation was verified visually and their fitness was classified into good, fair, bad, and incomplete. The result was 40%, 14%, 22%, 24% respectively. Using calculated deviations classified as good (994 images), we analyzed setup deviations. Overall setup deviations described in 1 SD along axes x, y, z, was 1.9 mm, 2.5 mm, 1.7 mm respectively. We classified these deviations into systematic and random components, and found that random error was predominant in our institute. The setup deviations along axis y (cranio-caudal direction) showed larger distribution when treatment was performed with the shell. Deviations along y (cranio-caudal) and z (anterior-posterior) had larger distribution when treatment occurred with the patient's arm elevated. There was a significant time-trend error, whose deviations become greater with time. Within all evaluated ports, 30% showed a time-trend error. Using an electronic portal imaging device and automatic image comparison algorithm, we are able to analyze setup deviations more precisely and improve setup method based on objective criteria. (author)

  10. Novel Rat Model of Repetitive Portal Venous Embolization Mimicking Human Non-Cirrhotic Idiopathic Portal Hypertension

    DEFF Research Database (Denmark)

    Klein, Sabine; Hinüber, Christian; Hittatiya, Kanishka

    2016-01-01

    BACKGROUND: Non-cirrhotic idiopathic portal hypertension (NCIPH) is characterized by splenomegaly, anemia and portal hypertension, while liver function is preserved. However, no animal models have been established yet. This study assessed a rat model of NCIPH and characterized the hemodynamics......, and compared it to human NCIPH. METHODS: Portal pressure (PP) was measured invasively and coloured microspheres were injected in the ileocecal vein in rats. This procedure was performed weekly for 3 weeks (weekly embolization). Rats without and with single embolization served as controls. After four weeks (one...... in the weekly embolization group. Fibrotic markers αSMA and Desmin were upregulated in weekly embolized rats. DISCUSSION: This study establishes a model using repetitive embolization via portal veins, comparable with human NCIPH and may serve to test new therapies....

  11. GENIUS: a web portal for the grid

    International Nuclear Information System (INIS)

    Andronico, A.; Barbera, R.; Falzone, A.; Lo Re, G.; Pulvirenti, A.; Rodolico, A.

    2003-01-01

    The architecture and the current implementation of the grid portal GENIUS (Grid Enabled web environment for site Independent User job Submission), jointly developed by INFN and NICE within the context of the INFN Grid and DataGrid Project, is presented and discussed

  12. Diagnosis of portal hypertension with radioactive isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Lewitus, Z

    1974-01-01

    Administration of /sup 131/I in a microclysma and simultaneous recording of the radioactivity in the liver and precordium allows the diagnosis of portal hypertension in at least 90 percent of the cases. This test has been used now for more than 5 years in patients with liver diseases. The simplicity of the test makes it a valuable bedside procedure.

  13. Extrahepatic complications to cirrhosis and portal hypertension

    DEFF Research Database (Denmark)

    Møller, Søren; Henriksen, Jens H; Bendtsen, Flemming

    2014-01-01

    In addition to complications relating to the liver, patients with cirrhosis and portal hypertension develop extrahepatic functional disturbances of multiple organ systems. This can be considered a multiple organ failure that involves the heart, lungs, kidneys, the immune systems, and other organ...

  14. Liver surgery in cirrhosis and portal hypertension.

    Science.gov (United States)

    Hackl, Christina; Schlitt, Hans J; Renner, Philipp; Lang, Sven A

    2016-03-07

    The prevalence of hepatic cirrhosis in Europe and the United States, currently 250 patients per 100000 inhabitants, is steadily increasing. Thus, we observe a significant increase in patients with cirrhosis and portal hypertension needing liver resections for primary or metastatic lesions. However, extended liver resections in patients with underlying hepatic cirrhosis and portal hypertension still represent a medical challenge in regard to perioperative morbidity, surgical management and postoperative outcome. The Barcelona Clinic Liver Cancer classification recommends to restrict curative liver resections for hepatocellular carcinoma in cirrhotic patients to early tumor stages in patients with Child A cirrhosis not showing portal hypertension. However, during the last two decades, relevant improvements in preoperative diagnostic, perioperative hepatologic and intensive care management as well as in surgical techniques during hepatic resections have rendered even extended liver resections in higher-degree cirrhotic patients with portal hypertension possible. However, there are few standard indications for hepatic resections in cirrhotic patients and risk stratifications have to be performed in an interdisciplinary setting for each individual patient. We here review the indications, the preoperative risk-stratifications, the morbidity and the mortality of extended resections for primary and metastatic lesions in cirrhotic livers. Furthermore, we provide a review of literature on perioperative management in cirrhotic patients needing extrahepatic abdominal surgery and an overview of surgical options in the treatment of hepatic cirrhosis.

  15. [Evaluation and treatment of portal hypertension].

    Science.gov (United States)

    Brůha, Radan; Petrtýl, Jaromír

    Liver cirrhosis is a serious disease shortening the life expectancy. Unavoidable consequence of cirrhosis is portal hypertension, which usually limits the prognosis by its complications. Portal hypertension is a prognostic factor for cirrhosis decompensation, variceal bleeding and even the mortality in cirrhotic patients. In the evaluation of portal hypertension hepatic venous pressure gradient (HVPG) measurement is used.Measurement of HVPG is used in clinical praxis in these situations: diagnosis of portal hypertension, evaluation of prognosis of patients with cirrhosis, monitoring the treatment efficacy in the prevention of variceal bleeding, management of acute variceal bleeding. Decrease of HVPG below 12 mmHg or at least for more than 20% of initial value in the treatment by beta-blockers is associated with the lower risk of bleeding from varices or other complications. HVPG above 20 mm Hg is associated with the high risk of early rebleeding from varices and can discriminate those patients profiting from early TIPS.HVPG measurement is an invasive, but simple, reproducible and safe catheterization technique with minimal complication rate. The most frequent complication could be incorrect assessment of obtained values. HVPG measurement should be a routine technique in centers specialized to liver diseases.

  16. Measuring Problem Solving Skills in "Portal 2"

    Science.gov (United States)

    Shute, Valerie J.; Wang, Lubin

    2013-01-01

    This paper examines possible improvement to problem solving skills as a function of playing the video game "Portal 2." Stealth assessment is used in the game to evaluate students' problem solving abilities--specifically basic and flexible rule application. The stealth assessment measures will be validated against commonly accepted…

  17. Portal hypertension due to choledochal cyst

    International Nuclear Information System (INIS)

    Athar, M.; Haider, M.H.R.; Khan, M.A.; Khaliq, T.; Ahmad, N.

    2002-01-01

    A case of portal hypertension secondary to choledochal cyst is reported. A young female presented with haematemesis, malena and splenomegaly in addition to the classic triad of jaundice, pain and abdominal mass. Oesophagogastroscopy revealed second degree varices. Excision of cyst and hepaticojejunostomy was performed. At six months follow up patient was completely asymptomatic with no endoscopic evidence of varices. (author)

  18. An Empirical Investigation of Campus Portal Usage

    Science.gov (United States)

    Saghapour, Mohsen; Iranmanesh, Mohammad; Zailani, Suhaiza; Goh, Gerald Guan Gan

    2018-01-01

    This study has determined the determinants of the perceived ease of use and perceived usefulness and their influence on campus portal usage. A quantitative approach was employed, using a five-point Likert scale questionnaire, adapted from previous studies. Data were gathered through a survey conducted with 341 staff working in the University of…

  19. Physics Experiments at the UNEDLabs Portal

    Directory of Open Access Journals (Sweden)

    Juan pedro Sánchez

    2012-01-01

    Full Text Available UNEDLabs is a web portal based on a free, modern, open source, and well-known learning management system: Moodle. This portal joins two theme networks of virtual and remote laboratories (one for Control Engineering and another one for Physics, named AutomatL@bs and FisL@bs, respectively together. AutomatL@bs has been operative for five years now. Following AutomatL@bs’ scheme, FisL@bs was created as a network of remote and virtual laboratories for physics university education via the Internet to offer students the possibility of performing hands-on experiences in different fields of physics in two ways: simulation and real remote operation. Now, both FisL@bs and AutomatL@bs join together (while maintaining their independency into an unique new web portal called UNEDLabs. This work focuses on this new web environment and gives a detailed account of a novel way in Physics to let distance learning students gain practical experience autonomously. This paper explains how the new portal works and the software tools used for creating it. In addition, it also describes the physics experiments which are already operative.

  20. ICPP digital wide area portal monitor

    International Nuclear Information System (INIS)

    Nichols, C.E.

    1978-01-01

    A portal montior is described which is used to check personnel for contamination. The monitor is extremely sensitive. In addition to personnel contamination control, it serves as an extremely effective SNM detector capable of detecting U-235 in half the quantities specified in Federal Standards

  1. A neutron portal monitor for vehicles

    International Nuclear Information System (INIS)

    Coop, K.L.; Fehlau, P.E.; Atwater, H.F.

    1987-01-01

    We have designed and built a portal vehicle monitoring systems for detecting neutron-emitting special nuclear material (SNM) such as plutonium. Monte Carlo calculations were used to optimize the design of the 15-cm-deep x 122-cm-high x 244-cm-long detector chambers, which utilize 3 He proportional counters inside a hollow polyethylene box. Results for a variety of parametric studies, including polyethylene thickness and detector number, are described. Our experimental measurements are in good agreement with the computer calculations. The monitor's decision logic uses the Sequential Probability Ratio Test (SPRT) on Poisson distributed counting data, which is superior to other statistical tests in many applications. We performed computer simulations of the SPRT logic to determine expected false-positive decision rates. A controller unit of our design that uses this SPRT was built commercially. The cost of the complete monitoring system is similar to that of vehicle portal monitors that detect gamma rays. This new neutron monitor can serve as an addition to standard gamma-ray vehicle portals or as a stand-alone portal monitor in particular safeguards monitoring situations. The monitor is being tested at Los Alamos and is scheduled for in-plant evaluation of another DOE facility in 1987. 7 refs

  2. Left-sided portal hypertension revisited

    Directory of Open Access Journals (Sweden)

    Antonio Manenti

    2016-12-01

    Conclusions: In every case of left-sided portal hypertension, upper digestive endoscopy and close follow-up are recommended. Besides, computed tomography can demonstrate particular conditions directly favoring gastroesophageal varices, and aid in selection of the appropriate therapeutic decisions. [Arch Clin Exp Surg 2016; 5(4.000: 211-215

  3. Portal hypertension in schistosomiasis: pathophysiology and treatment

    Directory of Open Access Journals (Sweden)

    Luiz Caetano da Silva

    1992-01-01

    Full Text Available In heavily infected young patients, there is a "non-congestive" phase of the disease with splenomegaly which can improve after chemoterapy. A strong correlation between hepatosplenic form and worm burden in young patients has been repeatedly shown. The pattern of vascular intrhepatic lesions seems to depend on two mechanisms: (a egg embolization, with a partial blocking of the portal vasculature; (b the appearance of small portal collaterals along the intrahepatic portal sistem. The role played by hepatitis B virus (HBV and C virus infections in the pathogenesis of liver lesions is variably considered. Selective arteriography shows a reduced diameter of hepatic artery with thin and arched branches outlining vascular gaps. A rich arterial network , as described in autopsy cases, is usually not seen in vivo, except after splenectomy or shunt surgery. An augmented hepatic arterial flow was demonstrated in infected animals. These facts suggest that the poor intrahepatic arterial vascularization demonstrated by selective arteriography in humans is due to a "functional deviation"of arterial blood to the splenic territory. The best results obtained in treatment of portal hypertension were: esophagogastric desvascularization and splenectomy (EGDS, although risk of rebleeding persists; classical (proximal splenorenal shunt (SRS should be abandoned; distal splenorenal shunt may complicate with hepatic encephalopaty, although later and in a lower percentage than in SRS. Propranolol is currently under investigation. In our Department, schistosomotic patients with esophageal varices bleeding are treated by EGDS and, if rebleeding occurs, by sclerosis of the varices.

  4. Portal Environment in Today’s Business

    OpenAIRE

    Aldubaikhi, Ammar

    2015-01-01

    Companies can get benefits from new business models as they can have better and efficient collaboration system and this can be derived from the discussed application in this paper. Companies that easily personalize the SAP enterprise portal are more productive and this reflects their interests in business

  5. Morphological and biomechanical remodeling of the hepatic portal vein in a swine model of portal hypertension.

    Science.gov (United States)

    He, Xi-Ju; Huang, Tie-Zhu; Wang, Pei-Jun; Peng, Xing-Chun; Li, Wen-Chun; Wang, Jun; Tang, Jie; Feng, Na; Yu, Ming-Hua

    2012-02-01

    To obtain the morphological and biomechanical remodeling of portal veins in swine with portal hypertension (PHT), so as to provide some mechanical references and theoretical basis for clinical practice about PHT. Twenty white pigs were used in this study, 14 of them were subjected to both carbon tetrachloride- and pentobarbital-containing diet to induce experimental liver cirrhosis and PHT, and the remaining animals served as the normal controls. The morphological remodeling of portal veins was observed. Endothelial nitric oxide synthase expression profile in the vessel wall was assessed at both mRNA and protein level. The biomechanical changes of the hepatic portal veins were evaluated through assessing the following indicators: the incremental elastic modulus, pressure-strain elastic modulus, volume elastic modulus, and the incremental compliance. The swine PHT model was successfully established. The percentages for the microstructural components and the histological data significantly changed in the experimental group. Endothelial nitric oxide synthase expression was significantly downregulated in the portal veins of the experimental group. Three incremental elastic moduli (the incremental elastic modulus, pressure-strain elastic modulus, and volume elastic modulus) of the portal veins from PHT animals were significantly larger than those of the controls (P portal vein decreased. Our study suggests that the morphological and biomechanical properties of swine hepatic portal veins change significantly during the PHT process, which may play a critical role in the development of PHT and serve as potential therapeutic targets during clinical practice. Copyright © 2012 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  6. Wall shear stress in portal vein of cirrhotic patients with portal hypertension.

    Science.gov (United States)

    Wei, Wei; Pu, Yan-Song; Wang, Xin-Kai; Jiang, An; Zhou, Rui; Li, Yu; Zhang, Qiu-Juan; Wei, Ya-Juan; Chen, Bin; Li, Zong-Fang

    2017-05-14

    To investigate wall shear stress (WSS) magnitude and distribution in cirrhotic patients with portal hypertension using computational fluid dynamics. Idealized portal vein (PV) system models were reconstructed with different angles of the PV-splenic vein (SV) and superior mesenteric vein (SMV)-SV. Patient-specific models were created according to enhanced computed tomography images. WSS was simulated by using a finite-element analyzer, regarding the blood as a Newtonian fluid and the vessel as a rigid wall. Analysis was carried out to compare the WSS in the portal hypertension group with that in healthy controls. For the idealized models, WSS in the portal hypertension group (0-10 dyn/cm 2 ) was significantly lower than that in the healthy controls (10-20 dyn/cm 2 ), and low WSS area (0-1 dyn/cm 2 ) only occurred in the left wall of the PV in the portal hypertension group. Different angles of PV-SV and SMV-SV had different effects on the magnitude and distribution of WSS, and low WSS area often occurred in smaller PV-SV angle and larger SMV-SV angle. In the patient-specific models, WSS in the cirrhotic patients with portal hypertension (10.13 ± 1.34 dyn/cm 2 ) was also significantly lower than that in the healthy controls ( P portal hypertension, the low WSS area extended to wider levels and the magnitude of WSS reached lower levels, thereby being more prone to disturbed flow occurrence. Cirrhotic patients with portal hypertension show dramatic hemodynamic changes with lower WSS and greater potential for disturbed flow, representing a possible causative factor of PV thrombosis.

  7. Development of a computerized portal verification scheme for pelvic treatment fields

    International Nuclear Information System (INIS)

    Nie, K.; Yin, F.-F.; Gao, Q.; Brasacchio, R.

    1996-01-01

    Purpose/Objective: At present, treatment verification between portal and reference images is performed based on manually-identified features by radiation oncologist, which is both time-consuming and potentially error-prone. There is a demand for the computerized verification procedure in clinical application. The purpose of this study is to develop a computerized portal verification scheme for pelvic treatment fields. Materials/Methods: The automated verification system involves image acquisition, image feature extraction, feature matching between reference and portal images and quantitative evaluation of patient setup. Electronic portal images with a matrix size of 256 x 256 and 12 bit gray levels were acquired using a liquid matrix electronic portal imaging device. Simulation images were acquired by digitizing simulation films using a TV camera into images with 256 x 256 matrix and 8 bit gray levels. Initially a Canny edge detector is applied to identify the field edges and an elliptic Fourier transformation is used to correlate the size and shape information between the reference and portal field edges. Several measures can be calculated using the transformation coefficients to describe the field shape, size and orientation. The quantitative information regarding to the relative shifts, rotation and magnification factor between portal and reference field edges can then be determined based on these measures. Next the pelvic brim, which is typically used as the landmark for radiation treatment verification, is identified by a pyramid searching process with double snakes defined from initial global area to final local area. A snake is an active model and energy-minimizing spline guided by external constraint forces and influenced by image forces that pull it toward features such as lines and edges. The search range is limited to the region between two snakes. Sobel edge detector and wavelet transformation approach are used to generate a serial image forces at

  8. Comparison of MCNP and Experimental Measurements for an HPGe-based Spectroscopy Portal Monitor

    International Nuclear Information System (INIS)

    Keyser, Ronald M.; Hensley, Walter K.; Twomey, Timothy R.; UPP, Daniel L.

    2008-01-01

    The necessity to monitor international commercial transportation for illicit nuclear materials resulted in the installation of many nuclear radiation detection systems in Portal Monitors. These were mainly gross counters which alarmed at any indication of high radioactivity in the shipment, the vehicle or even the driver. The innocent alarm rate, due to legal shipments of sources and NORM, or medical isotopes in patients, caused interruptions and delays in commerce while the legality of the shipment was verified. To overcome this difficulty, Department of Homeland Security (DHS) supported the writing of the ANSI N42.38 standard (Performance Criteria for Spectroscopy-Based Portal Monitors used for Homeland Security) to define the performance of a Portal Monitor with nuclide identification capabilities, called a Spectroscopy Portal Monitor. This standard defines detection levels and response characteristics for the system for energies from 25 keV to 3 MeV. To accomplish the necessary performance, several different HPGe detector configurations were modeled using MCNP for the horizontal field of view (FOV) and vertical linearity of response over the detection zone of 5 meters by 4.5 meters for 661 keV as representative of the expected nuclides of interest. The configuration with the best result was built and tested. The results for the FOV as a function of energy and the linearity show good agreement with the model and performance exceeding the requirements of N42.38

  9. Palliative treatment of TIPS to portal vein tumor thrombosis complicated with portal vein hypertension

    International Nuclear Information System (INIS)

    Jiang Zaibo; Shan Hong; Guan Shouhai; Zhu Kangshun; Huang Mingsheng; Li Zhengran; Guo Tiansheng; Liu Lang

    2002-01-01

    Objective: To evaluate the palliative therapeutic effects of transjugular intrahepatic portosystemic shunt (TIPS) in portal vein tumor thrombosis (PVTT) complicated with portal vein hypertension, and to discuss the technical skills. Methods: There were 14 cases of end-stage hepatocellular carcinoma complicated with PVTT and portal vein hypertension, the average age was 53.6 yr. There were 8 cases with complete occlusion of main portal vein, 6 eases with incomplete thrombosis, and 5 cases combined with portal vein cavernous transformation. One case had simple hemorrhage, 3 eases had intractable ascites, and 10 cases had hemorrhage accompanied by intractable ascites. Results: The procedure of TIPS was successful in 10 cases, the successful rate was about 71%. The mean portal vein pressure was reduced from 37.2 mm Hg to 18.2 mm Hg, with an average reduction of 19.0 mm Hg. After the procedure of TIPS, the ascites decreased, hemorrhage stopped and the clinical symptoms disappeared. The average survival period was 132.3 days. The procedure were failing in 4 cases. Conclusion: TIPS was an effective palliative therapeutic methods to control the hemorrhage and ascites aroused by hepatic carcinoma complicated with PVTT

  10. The application of TIPSS in portal vein cancerous thrombosis complicated with portal hypertension

    International Nuclear Information System (INIS)

    Jiang Zaibo; Shan Hong; Guan Shouhai; Zhu Kangshun; Huang Mingsheng; Li Zhengran; Zhu Wenke; Liu Lang; Guo Tiansheng

    2002-01-01

    Objective: To discuss the technical skills and the contraindication of trans-jugular intrahepatic portosystemic shunt stent (TIPSS) in portal vein cancerous thrombosis (PVCT) complicated with portal hypertension. Methods: There were 16 cases of PVCT with portal hypertension, and average age of 53.6 yr. There were 9 cases with complete occlusion of portal vein trunk and 7 cases with incomplete thrombosis. There were 5 cases with cavernous transformation of the portal vein (CTPV). 1 case of simple upper gastro-intestinal tract (GIT) massive bleeding, 4 with refractory ascites and 11 with upper GIT massive bleeding and refractory ascites. Results: The procedure of TIPS was successful in 11 cases, the successful rate reached about 68.8%. The mean portal vein pressure was reduced from 4.9 kPa to 2.4 kPa with average 2. 5 kPa reduction. Ascites decreased, bleeding stopped and the clinical symptoms disappeared. The average survival period was 136 days. The procedure failed in 5 cases. Conclusions: TIPSS is an effective method to control the bleeding and ascites caused by PVCT. The PV cavernous transformation was the contraindication of TIPSS

  11. Anatomy of the Portal Vein Bifurcation: Implication for Transjugular Intrahepatic Portal Systemic Shunts

    International Nuclear Information System (INIS)

    Kwok, Philip Chong-hei; Ng, Wai Fu; Lam, Christine Suk-yee; Tsui, Polly Po; Faruqi, Asma

    2003-01-01

    Purpose: The relationship of the portalvein bifurcation to the liver capsule in Asians, which is an important landmark for transjugular intrahepatic portosystemic shunt, has not previously been described. Methods: The anatomy of the portal vein bifurcation was studied in 70 adult Chinese cadavers; it was characterized as intrahepatic or extrahepatic. The length of the exposed portion of the right and left portal veins was measured when the bifurcation was extrahepatic. Results: The portal vein bifurcation was intrahepatic in 37 cadavers (53%) and extrahepatic in 33 cadavers (47%). The mean length of the right and left extrahepatic portal veins was 0.96 cm and 0.85 cm respectively.Both were less than or equal to 2 cm in 94% of the cadavers with extrahepatic bifurcation. There was no correlation between the presence of cirrhosis and the location of the portal vein bifurcation(p 1.0). There was no statistically significant difference in liver mass in cadavers with either extrahepatic or intrahepatic bifurcation (p =0.40). Conclusions: These findings suggest that fortransjugular intrahepatic portosystemic shunt placement, a portal vein puncture 2 cm from the bifurcation will be safe in most cases

  12. Radioisotopic splenoportography in patients with portal hypertension

    International Nuclear Information System (INIS)

    Samejima, Natsuki; Ikeda, Koichiro; Yokoyama, Yasuhiro; Hirata, Satoru

    1989-01-01

    Radio-isotopic splenoportography was performed by injecting 99m TcO 4 - into the spleens of 46 patients with portal hypertension and 14 patients with various disorders not having portal hypertension. No collateral circulation was demonstrated in the 14 patients without portal hypertension whereas some RI-images of portosystemic collaterals were found in 40 (87.0 per cent) of the 46 patients with portal hypertension. Collaterals were divided into an ascending group and a descending group, the appearance rate of ascending collaterals being 80.4 per cent and that of descending collaterals, 41.3 per cent. There were 3 image patterns in the ascending group, namely, an AZ-pattern in which the azygos vein was demonstrated; a SC-pattern in which the RI-bolus ascended along the esophagus to the neck and the subclavian vein; and an EG-pattern which showed stagnation of the RI-bolus in the esophagogastric region. There were 4 patterns in the descending group, namely; a pattern of gastro-renal caval shunt (GR-pattern); reverse flow patterns into the umbilical or paraumbilical veins (UV-pattern); into the superior mesenteric vein (SMV-pattern); and into the inferior mesenteric vein (IMV-pattern). The appearance of the EG-pattern was seen most frequently (74.4 per cent). The usefulness of this method for surveying the collateral circulation in portal hypertension, estimating the risk of esophageal variceal bleeding and evaluating its treatments, was suggested by the results of this study. (author)

  13. CT of portal vein tumor thrombosis. Usefulness of dynamic CT

    Energy Technology Data Exchange (ETDEWEB)

    Takemoto, Kazumasa; Inoue, Yuichi; Tanaka, Masahiro; Nemoto, Yutaka; Nakamura, Kenji [Osaka City Univ. (Japan). Faculty of Medicine

    1983-08-01

    We evaluated CT findings of portal vein tumor thrombosis in 16 hepatomas by plain, contrast and dynamic CT. Plain and contrast CT findings were an enlargement of the portal vein (81%), intraluminal low density area (63%). Dynamic CT enhanced the diagnostic capability of the tumor thrombus as a relatively low density area because of the marked enhancement of the portal vein. In addition, dynamic CT newly demonstrated hyperdense peripheral ring (35%) and arterio portal shunt (35%). It is advisable to select the scan level to include the portal vein when dynamic CT is performed in the patient of hepatocellular carcinoma.

  14. Portal hypertension as portrayed by marked hepatosplenomegaly: case report

    International Nuclear Information System (INIS)

    Greene, R.A.

    1987-01-01

    The liver is vulnerable to as host of disease processes, including portal hypertension. This is a severe hepatic condition in which the liver is subject to numerous imbalances: increased hepatic blood flow, increased portal vein pressure due to extrahepatic portal vein obstruction, and/or increases in hepatic blood flow resistance. Although many diseases states may be responsible for the development of portal hypertension, it is most commonly associated with moderately severe or advanced cirrhosis. Advanced, untreated portal hypertension may cause additional complications such as hepatosplenomegaly, gastrointestinal bleeding, and ascites

  15. Splenomegaly, hyperkinetic splenic flow and portal hypertension in colitis

    Energy Technology Data Exchange (ETDEWEB)

    Friman, L [Serafimerlasarettet, Stockholm (Sweden)

    1980-01-01

    Four patients with a long history of colitis, splenomegaly, hypersplenism and portal hypertension were examined with angiography, both with contrast medium and isotopes, liver-spleen scintigraphy and recording of portal pressure. At angiography hyperkinetic splenic and portal blood flow was demonstrated. The increased flow causes increased portal pressure, which probably gives rise to changes in the liver often considered as slight cirrhosis at microscopy. The scintigraphic findings differed from Laennec cirrhosis. The liver uptake was homogeneous and no activity in the skeleton was recorded. Splenectomy cures both the hypersplenism and portal hypertension.

  16. Pathophysiology of Portal Hypertension and Its Clinical Links

    Science.gov (United States)

    Seo, Yeon Seok; Shah, Vijay H

    2011-01-01

    Portal hypertension is a major cause of morbidity and mortality in patients with liver cirrhosis. Intrahepatic vascular resistance due to architectural distortion and intrahepatic vasoconstriction, increased portal blood flow due to splanchnic vasodilatation, and development of collateral circulation have been considered as major factors for the development of portal hypertension. Recently, sinusoidal remodeling and angiogenesis have been focused as potential etiologic factors and various researchers have tried to improve portal hypertension by modulating these new targets. This article reviews potential new treatments in the context of portal hypertension pathophysiology concepts. PMID:25755320

  17. Splenomegaly, hyperkinetic splenic flow and portal hypertension in colitis

    International Nuclear Information System (INIS)

    Friman, L.

    1980-01-01

    Four patients with a long history of colitis, splenomegaly, hypersplenism and portal hypertension were examined with angiography, both with contrast medium and isotopes, liver-spleen scintigraphy and recording of portal pressure. At angiography hyperkinetic splenic and portal blood flow was demonstrated. The increased flow causes increased portal pressure, which probably gives rise to changes in the liver often considered as slight cirrhosis at microscopy. The scintigraphic findings differed from Laennec cirrhosis. The liver uptake was homogeneous and no activity in the skeleton was recorded. Splenectomy cures both the hypersplenism and portal hypertension. (Auth.)

  18. Analysis of Dynamic Characteristics of Portal Frame with Variable Section

    Directory of Open Access Journals (Sweden)

    Hao Jianing

    2016-01-01

    Full Text Available Combined with a portal frame design, by the use of finite element software ANSYS, the finite element model of single specimens of portal rigid frame and the overall portal rigid frame building are established. portal rigid frame’s beam and column is variable cross section. Through the modal analysis, comparative analysis of the frequency and vibration type of the radiolabeling specimens and finite element model of the whole, for the further development of variable cross-section portal rigid frame of earthquake and wind vibration analysis lay the foundation.

  19. Database for radiation therapy images

    International Nuclear Information System (INIS)

    Shalev, S.; Cosby, S.; Leszczynski, K.; Chu, T.

    1989-01-01

    The authors have developed a database for images acquired during simulation and verification of radiation treatments. Simulation images originate as planning films that are digitized with a video camera, or through direct digitization of fluoroscopic images. Verification images may also be digitized from portal films or acquired with an on-line portal imaging system. Images are classified by the patient, the fraction, the field direction, static or dynamic (movie) sequences, and the type of processing applied. Additional parameters indicate whether the source is a simulation or treatment, whether images are digitized film or real-time acquisitions, and whether treatment is portal or double exposure for beam localization. Examples are presented for images acquired, processed, stored, and displayed with on-line portal imaging system (OPIUM) and digital simulation system (FLIP)

  20. Integrated neutron/gamma-ray portal monitors for nuclear safeguards

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1994-01-01

    Radiation monitoring is one nuclear-safeguards measure used to protect against the theft of special nuclear materials (SNM) by pedestrians departing from SNM access areas. The integrated neutron/gamma-ray portal monitor is an ideal radiation monitor for the task when the SNM is plutonium. It achieves high sensitivity for detecting both bare and shielded plutonium by combining two types of radiation detector. One type is a neutron-chamber detector, comprising a large, hollow, neutron moderator that contains a single thermal-neutron proportional counter. The entrance wall of each chamber is thin to admit slow neutrons from plutonium contained in a moderating shield, while the other walls are thick to moderate fast neutrons from bare or lead-shielded plutonium so that they can be detected. The other type of detector is a plastic scintillator that is primarily for detecting gamma rays from small amounts of unshielded plutonium. The two types of detector are easily integrated by making scintillators part of the thick back wall of each neutron chamber or by inserting them into each chamber void. The authors compared the influence of the two methods of integration on detecting neutrons and gamma rays, and they examined the effectiveness of other design factors and the methods for signal detection as well

  1. Portal Vein Dopplerflowmetry in healthy sheep according to age

    Directory of Open Access Journals (Sweden)

    Alexandra F. Belotta

    Full Text Available ABSTRACT: Pulsed Doppler ultrasound was used to evaluate portal blood flow, portal velocity and portal congestion index in 24 healthy sheep divided into groups (lambs, yearlings and ewes, according to age. Measurements were performed at the 11th right intercostal space using ideal insonation angle and uniform insonation method. Mean values obtained in each group were compared with one-way ANOVA, followed by Tukey post-hoc test. Portal velocity and portal blood flow were statistically similar between the groups (P>0.05. Mean portal velocity were 17.75; 17.13 and 16.75; while mean portal blood flow were 26.65; 31.04 and 24.32 for lambs, yearlings and ewes, respectively. Portal congestion index was statistically distinct between the groups and values for lambs, yearlings and ewes were 0.009; 0.058 and 0.09, respectively (P<0.01. Statistical differences were observed in portal vein diameter, portal vein area and portal congestion index between the groups, presumably due to influence of weight and not to age.

  2. Strategi Branding Portal Online Www.tripriau.com Dalam Membangun Brand Awareness Sebagai Portal Online Pariwisata Provinsi Riau

    OpenAIRE

    Rahmadhani, Yuri; Lubis, Evawani Elysa

    2017-01-01

    Online portal www.tripriau.com online portal is one of the online portal in Riau Province that has its own uniqueness. These portals contain local content and the potential of tourism in the province of Riau. Since its establishment, www.tripriau.com do branding strategy in order to build brand awareness or trust the reader to be known as a tourism-themed online portal. As the selection of brand name Trip Riau, Riau Guide My tagline, as well as the implementation of travel instagram photo con...

  3. Colangiopatía portal: complicación poco frecuente de la hipertensión portal

    OpenAIRE

    Veloso, Victoria; Servente, Liliana; Hernández, Nelia

    2017-01-01

    Resumen: Se describe el caso clínico de una mujer de 62 años en la que se diagnostica una estenosis del colédoco en el contexto de hipertensión portal prehepática (cavernomatosis portal). Abstract: We report the case of a 62 years old woman with a choledochal stricture and chronic obstruction of the portal vein (portal cavernomatosis). Resumo: Relatamos o caso de uma mulher de 62 anos com diagnóstico de estenose do colédoco no contexto da hipertensão portal pré-hepática (cavernomat...

  4. DES Science Portal: Computing Photometric Redshifts

    Energy Technology Data Exchange (ETDEWEB)

    Gschwend, Julia [LIneA, Rio de Janeiro

    2016-01-01

    An important challenge facing photometric surveys for cosmological purposes, such as the Dark Energy Survey (DES), is the need to produce reliable photometric redshifts (photo-z). The choice of adequate algorithms and configurations and the maintenance of an up-to-date spectroscopic database to build training sets, for example, are challenging tasks when dealing with large amounts of data that are regularly updated and constantly growing. In this paper, we present the first of a series of tools developed by DES, provided as part of the DES Science Portal, an integrated web-based data portal developed to facilitate the scientific analysis of the data, while ensuring the reproducibility of the analysis. We present the DES Science Portal photometric redshift tools, starting from the creation of a spectroscopic sample to training the neural network photo-z codes, to the final estimation of photo-zs for a large photometric catalog. We illustrate this operation by calculating well calibrated photo-zs for a galaxy sample extracted from the DES first year (Y1A1) data. The series of processes mentioned above is run entirely within the Portal environment, which automatically produces validation metrics, and maintains the provenance between the different steps. This system allows us to fine tune the many steps involved in the process of calculating photo-zs, making sure that we do not lose the information on the configurations and inputs of the previous processes. By matching the DES Y1A1 photometry to a spectroscopic sample, we define different training sets that we use to feed the photo-z algorithms already installed at the Portal. Finally, we validate the results under several conditions, including the case of a sample limited to i<22.5 with the color properties close to the full DES Y1A1 photometric data. This way we compare the performance of multiple methods and training configurations. The infrastructure presented here is an effcient way to test several methods of

  5. Improving diabetes management with a patient portal: a qualitative study of diabetes self-management portal.

    Science.gov (United States)

    Urowitz, Sara; Wiljer, David; Dupak, Kourtney; Kuehner, Zachary; Leonard, Kevin; Lovrics, Emily; Picton, Peter; Seto, Emily; Cafazzo, Joe

    2012-11-30

    Effective management and care of diabetes is crucial to reducing associated risks such as heart disease and kidney failure. With increasing access and use of the Internet, online chronic disease management is being explored as a means of providing patients with support and the necessary tools to monitor and manage their disease. The objective of our study was to evaluate the experience of patients and providers using an online diabetes management portal for patients. Participants were recruited from a large sample population of 887 for a follow-up questionnaire to be completed after 6 months of using the patient portal. Participants were presented with the option to participate in an additional interview and, if the participant agreed, a time and date was scheduled for the interview. A 5-item, open-ended questionnaire was used to capture providers' opinions of the patient portal. Providers included general practitioners (GPs), nurses, nurse practitioners (NPs), dieticians, diabetes educators (DECs), and other clinical staff. A total of 854 patients were consented for the questionnaire. Seventeen (8 male, 9 female) patients agreed to participate in a telephone interview. Sixty-four health care providers completed the five open-ended questions; however, an average of 48.2 responses were recorded per question. Four major themes were identified and will be discussed in this paper. These themes have been classified as: facilitators of disease management, barriers to portal use, patient-provider communication and relationship, and recommendations for portal improvements. This qualitative study shows that online chronic disease management portals increase patient access to information and engagement in their health care, but improvements in the portal itself may improve usability and reduce attrition. Furthermore, this study identifies a grey area that exists in the roles that GPs and AHPs should play in the facilitation of online disease management.

  6. Real-time Cherenkov emission portal imaging during CyberKnife® radiotherapy

    International Nuclear Information System (INIS)

    Roussakis, Yiannis; Mason, Suzannah; Dehghani, Hamid; Zhang, Rongxiao; Heyes, Geoff; Webster, Gareth; Green, Stuart; Pogue, Brian

    2015-01-01

    The feasibility of real-time portal imaging during radiation therapy, through the Cherenkov emission (CE) effect is investigated via a medical linear accelerator (CyberKnife ® ) irradiating a partially-filled water tank with a 60 mm circular beam. A graticule of lead/plywood and a number of tissue equivalent materials were alternatively placed at the beam entrance face while the induced CE at the exit face was imaged using a gated electron-multiplying-intensified-charged-coupled device (emICCD) for both stationary and dynamic scenarios. This was replicated on an Elekta Synergy ® linear accelerator with portal images acquired using the iViewGT ™ system. Profiles across the acquired portal images were analysed to reveal the potential resolution and contrast limits of this novel CE based portal imaging technique and compared against the current standard. The CE resolution study revealed that using the lead/plywood graticule, separations down to 3.4  ±  0.5 mm can be resolved. A 28 mm thick tissue-equivalent rod with electron density of 1.69 relative to water demonstrated a CE contrast of 15% through air and 14% through water sections, as compared to a corresponding contrast of 19% and 12% using the iViewGT ™ system. For dynamic scenarios, video rate imaging with 30 frames per second was achieved. It is demonstrated that CE-based portal imaging is feasible to identify both stationary and dynamic objects within a CyberKnife ® radiotherapy treatment field. (note)

  7. Portal hypertensive polyps, a new entity?

    Directory of Open Access Journals (Sweden)

    Verónica Martín-Domínguez

    Full Text Available Presentamos el caso clínico de una mujer de 62 años de edad, con antecedentes de cirrosis hepática secundaria a hepatitis autoinmune, hipertensión portal y coagulopatía, quien presenta en gastroscopia, unas lesiones polipoideas, semipediculadas, polilobuladas en la región prepilórica, que se extirpan y cuya anatomía patológica se describe como pólipos hiperplásicos con edema, congestión vascular e hiperplasia del músculo liso, sin displasia ni cambios adenomatosos, correspondientes a "pólipos de la hipertensión portal" (PHP.

  8. Novel treatment options for portal hypertension

    Science.gov (United States)

    Laleman, Wim

    2017-01-01

    Abstract Portal hypertension is most frequently associated with cirrhosis and is a major driver for associated complications, such as variceal bleeding, ascites or hepatic encephalopathy. As such, clinically significant portal hypertension forms the prelude to decompensation and impacts significantly on the prognosis of patients with liver cirrhosis. At present, non-selective β-blockers, vasopressin analogues and somatostatin analogues are the mainstay of treatment but these strategies are far from satisfactory and only target splanchnic hyperemia. In contrast, safe and reliable strategies to reduce the increased intrahepatic resistance in cirrhotic patients still represent a pending issue. In recent years, several preclinical and clinical trials have focused on this latter component and other therapeutic avenues. In this review, we highlight novel data in this context and address potentially interesting therapeutic options for the future. PMID:28533907

  9. Portal Vein Embolization: What Do We Know?

    Energy Technology Data Exchange (ETDEWEB)

    Denys, Alban, E-mail: Alban.Denys@chuv.ch [Centre Hospitalo Universitaire Vaudois, Department of Radiology and Interventional Radiology Unit (Switzerland); Prior, John [Centre Hospitalo Universitaire Vaudois, Department of Nuclear Medicine (Switzerland); Bize, Pierre; Duran, Rafael [Centre Hospitalo Universitaire Vaudois, Department of Radiology and Interventional Radiology Unit (Switzerland); Baere, Thierry De [Institut Gustave Roussy, Department of Interventional Radiology (France); Halkic, Nermin; Demartines, Nicolas [Centre Hospitalo Universitaire Vaudois, Department of Visceral Surgery (Switzerland)

    2012-10-15

    Portal vein embolization (PVE) has been developed to increase the size of the future remnant liver (FRL) left in place after major hepatectomy, thus reducing the risk of postoperative liver insufficiency. PVE consist in embolizing preoperatively portal branches of the segments that will be resected. Indication is based on preoperative measurements of the FRL by computed tomography and its ratio with either the theoretical liver volume or by direct measurement of the functional liver volume. After PVE, the volume and function of the FRL increases in 3 to 6 weeks, permitting extensive resections in patients otherwise contraindicated for liver resection. The PVE technique is variable from one center to another; however n-butyl-cyano-acrylate provides an interesting compromise between hypertrophy rate and procedure risk.

  10. Spin-0± portal induced Dark Matter

    Science.gov (United States)

    Dutta, Sukanta; Goyal, Ashok; Saini, Lalit Kumar

    2018-02-01

    Standard model (SM) spin-zero singlets are constrained through their di-Bosonic decay channels via an effective coupling induced by a vector-like quark (VLQ) loop at the LHC for √{s}=13 TeV. These spin-zero resonances are then considered as portals for scalar, vector or fermionic dark matter particle interactions with SM gauge bosons. We find that the model is validated with respect to the observations from LHC data and from cosmology, indirect and direct detection experiments for an appreciable range of scalar, vector and fermionic DM masses greater than 300 GeV and VLQ masses ≥ 400 GeV, corresponding to the three choice of portal masses 270 GeV, 500 GeV and 750 GeV respectively.

  11. Gamma portal detector with micro-processed and GSM communication system

    International Nuclear Information System (INIS)

    Carneiro, Lindolff Thadeu

    2008-01-01

    Full text: We present in this paper a new concept of gamma radiation portal detector, where the detection process is monitored by a micro-controller, coupled to a compatible GSM communication system, which is suitable to be accessed by all mobile phone operators worldwide. The signal generated at the detectors is converted by an A/D circuit, and driven to a micro-controller where a software evaluates the signal conditions and, depending on a previously set program, it triggers a communication system which sends the alarm to any computer linked to internet and/or to any mobile phone protocol by a specific software linked to the portal. The control electronic system is compatible to several detectors types, ranging from gas based devices to solid state ones. The portal is totally compatible with the ANSI - Standard N42.35 - 2004. It can be used in all types of government and industrial control scenarios. Its measure device permits the use of the equipment in all range of sensibility and in tracking radiation signals where it is. (author)

  12. An analysis of splenoportographic findings in portal hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Eun Mi; Moon, Sook Ran; Kim, Han Suk [National Medical Center, Seoul (Korea, Republic of); Park, Soo Soung [College of Medicine, Chung Ang University, Seoul (Korea, Republic of)

    1983-12-15

    Splenoportography has been proved as a useful method for the evaluation of circulatory disturbances in portal hypertension. Authors analyzed the various aspects of these disturbance on splenoportography in 22 cases that was performed under the clinical suspicion of portal hypertension during recent 6 years, from May, 1976 to July 1982 at the Department of Radiology, National Medical Center. The results were as follows: 1. Liver cirrhosis was the most frequent cause of intrahepatic obstruction type in portal hypertension (86%). 2. The portal pressure was more than 400 mmH{sub 2}0 in 67% of the cases (range; 300-540 mmH{sub 2}0). 3. In the majority of the cases, the higher the portal pressure was, the more dilated splenic and portal veins were. The diameter of portal vein was more than 15 mm in 79%, more than 21 mm in 47% of the cases (range; 10-26 mm). The diameter of splenic vein was more than 15 mm in 48% of the cases (range; 7-23 mm). Especially the diameter of splenic vein was larger than that of portal vein in 20% of the cases. 4. There was no definite correlation between the development of collateral circulation and the diameter of splenic and portal veins. 5. The filling of collateral circulation was definite sign of portal hypertension, though not regular. In portal hypertension, the collateral circulation was formed via coronary vein (91%), short gastric vein (64%), inferior mesenteric vein (36%). 6. Splenic-hilum time was delayed in 64% of the cases. Intrahepatic portal vein emptying time was more than 6 seconds in all the cases. 7. Most of the cases (91%) could be diagnosed as portal hypertension with vasculogram and hepatogram.

  13. An analysis of splenoportographic findings in portal hypertension

    International Nuclear Information System (INIS)

    Jung, Eun Mi; Moon, Sook Ran; Kim, Han Suk; Park, Soo Soung

    1983-01-01

    Splenoportography has been proved as a useful method for the evaluation of circulatory disturbances in portal hypertension. Authors analyzed the various aspects of these disturbance on splenoportography in 22 cases that was performed under the clinical suspicion of portal hypertension during recent 6 years, from May, 1976 to July 1982 at the Department of Radiology, National Medical Center. The results were as follows: 1. Liver cirrhosis was the most frequent cause of intrahepatic obstruction type in portal hypertension (86%). 2. The portal pressure was more than 400 mmH 2 0 in 67% of the cases (range; 300-540 mmH 2 0). 3. In the majority of the cases, the higher the portal pressure was, the more dilated splenic and portal veins were. The diameter of portal vein was more than 15 mm in 79%, more than 21 mm in 47% of the cases (range; 10-26 mm). The diameter of splenic vein was more than 15 mm in 48% of the cases (range; 7-23 mm). Especially the diameter of splenic vein was larger than that of portal vein in 20% of the cases. 4. There was no definite correlation between the development of collateral circulation and the diameter of splenic and portal veins. 5. The filling of collateral circulation was definite sign of portal hypertension, though not regular. In portal hypertension, the collateral circulation was formed via coronary vein (91%), short gastric vein (64%), inferior mesenteric vein (36%). 6. Splenic-hilum time was delayed in 64% of the cases. Intrahepatic portal vein emptying time was more than 6 seconds in all the cases. 7. Most of the cases (91%) could be diagnosed as portal hypertension with vasculogram and hepatogram

  14. Computed tomographic evaluation of the portal vein in the hepatomas

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kee Hyung; Lee, Seung Chul; Bae, Man Gil; Seo, Heung Suk; Kim, Soon Yong; Lee, Min Ho; Kee, Choon Suhk; Park, Kyung Nam [Hanyang University College of Medicine, Seoul (Korea, Republic of)

    1986-10-15

    Computed tomography and pornographic findings of 63 patients with hepatoma, undergone hepatic angiography and superior mesenteric pornography for evaluation of tumor and thrombosis of portal vein and determination of indication of transcatheter arterial embolization for palliative treatment of hepatoma from April, 85 to June, 86 in Hanyang university hospital, were reviewed. The results were as follows: 1. In 36 cases, portal vein thrombosis was detected during photography. Nineteen of 37 cases which revealed localized hepatoma in the right lobe of the liver showed portal vein thrombosis; 9 of 11 cases of the left lobe; 8 of 14 cases which were involved in entire liver revealed thrombosis. One case localized in the caudate lobe showed no evidence of invasion to portal vein. 2. Twenty-four of 34 cases with diffuse infiltrative hepatoma revealed portal vein thrombosis and the incidence of portal vein thrombosis in this type were higher than in the cases of the nodular type. 3. The portal vein thrombosis appeared as filling defects of low density in the lumen of the portal veins in CT and they did not reveal contrast enhancement. 4. CT revealed well the evidence of obstructions in the cases of portal vein thrombosis and the findings were well-corresponded to the findings of the superior mesenteric photography. 5. Five of the cases of the portal vein thrombosis were missed in the CT and the causes were considered as due to partial volume effect of enhanced portal vein with partial occlusion or arterioportal shunts. 6. Six of 13 cases with occlusion of main portal vein showed cavernous transformation and they were noted as multiple small enhanced vascularities around the porta hepatis in the CT. According to the results, we conclude that CT is a useful modality to detect the changes of the portal veins in the patients of the hepatoma.

  15. Computed tomographic evaluation of the portal vein in the hepatomas

    International Nuclear Information System (INIS)

    Lee, Kee Hyung; Lee, Seung Chul; Bae, Man Gil; Seo, Heung Suk; Kim, Soon Yong; Lee, Min Ho; Kee, Choon Suhk; Park, Kyung Nam

    1986-01-01

    Computed tomography and pornographic findings of 63 patients with hepatoma, undergone hepatic angiography and superior mesenteric pornography for evaluation of tumor and thrombosis of portal vein and determination of indication of transcatheter arterial embolization for palliative treatment of hepatoma from April, 85 to June, 86 in Hanyang university hospital, were reviewed. The results were as follows: 1. In 36 cases, portal vein thrombosis was detected during photography. Nineteen of 37 cases which revealed localized hepatoma in the right lobe of the liver showed portal vein thrombosis; 9 of 11 cases of the left lobe; 8 of 14 cases which were involved in entire liver revealed thrombosis. One case localized in the caudate lobe showed no evidence of invasion to portal vein. 2. Twenty-four of 34 cases with diffuse infiltrative hepatoma revealed portal vein thrombosis and the incidence of portal vein thrombosis in this type were higher than in the cases of the nodular type. 3. The portal vein thrombosis appeared as filling defects of low density in the lumen of the portal veins in CT and they did not reveal contrast enhancement. 4. CT revealed well the evidence of obstructions in the cases of portal vein thrombosis and the findings were well-corresponded to the findings of the superior mesenteric photography. 5. Five of the cases of the portal vein thrombosis were missed in the CT and the causes were considered as due to partial volume effect of enhanced portal vein with partial occlusion or arterioportal shunts. 6. Six of 13 cases with occlusion of main portal vein showed cavernous transformation and they were noted as multiple small enhanced vascularities around the porta hepatis in the CT. According to the results, we conclude that CT is a useful modality to detect the changes of the portal veins in the patients of the hepatoma.

  16. Inpatient Portals for Hospitalized Patients and Caregivers: A Systematic Review.

    Science.gov (United States)

    Kelly, Michelle M; Coller, Ryan J; Hoonakker, Peter Lt

    2018-06-01

    Patient portals, web-based personal health records linked to electronic health records (EHRs), provide patients access to their healthcare information and facilitate communication with providers. Growing evidence supports portal use in ambulatory settings; however, only recently have portals been used with hospitalized patients. Our objective was to review the literature evaluating the design, use, and impact of inpatient portals, which are patient portals designed to give hospitalized patients and caregivers inpatient EHR clinical information for the purpose of engaging them in hospital care. Literature was reviewed from 2006 to 2017 in PubMed, Web of Science, CINALPlus, Cochrane, and Scopus to identify English language studies evaluating patient portals, engagement, and inpatient care. Data were analyzed considering the following 3 themes: inpatient portal design, use and usability, and impact. Of 731 studies, 17 were included, 9 of which were published after 2015. Most studies were qualitative with small samples focusing on inpatient portal design; 1 nonrandomized trial was identified. Studies described hospitalized patients' and caregivers' information needs and design recommendations. Most patient and caregiver participants in included studies were interested in using an inpatient portal, used it when offered, and found it easy to use and/or useful. Evidence supporting the role of inpatient portals in improving patient and caregiver engagement, knowledge, communication, and care quality and safety is limited. Included studies indicated providers had concerns about using inpatient portals; however, the extent to which these concerns have been realized remains unclear. Inpatient portal research is emerging. Further investigation is needed to optimally design inpatient portals to maximize potential benefits for hospitalized patients and caregivers while minimizing unintended consequences for healthcare teams. © 2017 Society of Hospital Medicine.

  17. Diavideos: a diabetes health video portal.

    Science.gov (United States)

    Sánchez-Bocanegra, C L; Rivero-Rodriguez, A; Fernández-Luque, L; Sevillano, J L

    2013-01-01

    Diavideos is a web platform that collects trustworthy diabetes health videos from YouTube and offers them in a easy way. YouTube is a big repository of health videos, but good content is sometimes mixed with misleading and harmful videos such as promoting anorexia [1]. Diavideos is a web portal that provides easy access to a repository of trustworthy diabetes videos. This poster describes Diavideos and explains the crawling method used to retrieve these videos from trusted channels.

  18. Liferay 6.x portal enterprise intranets cookbook

    CERN Document Server

    Filipowicz, Piotr

    2015-01-01

    If you are a Java developer or administrator with a technical background and want to install and configure Liferay Portal as an enterprise intranet, this is the book for you. In short, reusable recipes help you realize business goals as working features in Liferay. This book will also give you useful hints on how to easily improve the default functionality of the system and its performance.

  19. State of the SOOS GCMD Portal

    Science.gov (United States)

    Ritz, Scott

    2018-01-01

    A brief status update on NASA’s latest Global Change Master Directory (GCMD) keyword update, description of the differences between DIF-9 and DIF-10 formats in advance of the deprecation of DIF-9 support in Earth Observing System Data and Information System (EOSDIS) with specifics on the DIF-10.3 schema, transition schedule, and some usage metrics for the GCMD Southern Ocean Observing System (SOOS) Portal.

  20. Comparative methods of concrete portal frame design

    OpenAIRE

    A, Letengsang

    2014-01-01

    The objective of this thesis was to design a concrete portal frame with two column spacings of 12 meters and 6 meters and its structural elements in a building located in Hämeenlinna city, Finland. A comprehension study on the concrete design chapter of Eurocode 2 was done before proceeding on the calculation process, the materials’ properties. The corresponding ca-pacity diagrams from concrete product manufacturers in Finland can be assistance tools during the calculation process. ...

  1. Portal verification for breast cancer radiotherapy

    International Nuclear Information System (INIS)

    Petkovska, Sonja; Pejkovikj, Sasho; Apostolovski, Nebojsha

    2013-01-01

    At the University Clinic in Skopje, breast cancer irradiation is being planned and performed by using a mono-iso centrical method, which means that a unique isocenter (I C) for all irradiation fields is used. The goal of this paper is to present the patient’s position in all coordinates before the first treatment session, relative to the position determined during the CT simulation. Deviation of up to 5 mm is allowed. The analysis was made by using a portal verification. Sixty female patients at random selection are reviewed. The matching results show that for each patient deviation exists at least on one axis. The largest deviations are in the longitudinal direction (head-feet) up to 4 mm, mean 1.8 mm. In 60 out of 85 analysed fields, the deviation is towards the head. In lateral direction, median deviation is 1.1 mm and in 65% of the analysed portals those deviations are in medial direction – contralateral breast which can increases the dose in the lung and in the contralateral breast. This deviation for supraclavicular field can increase the dose in the spinal cord. Although these doses are well below the limit, this fact should be taken into account in setting the treatment fields. The final conclusion from the research is that despite of the fact we are dealing with small deviations, in conditions when accuracy in positioning is done with portal, the portal verification needs to be done in the coming weeks of the treatment, not only before the first treatment. This provides information for an intra fractional set-up deviation. (Author)

  2. Exploratory portals of research data in education

    Directory of Open Access Journals (Sweden)

    Di Blas Nicoletta

    2015-12-01

    Full Text Available This paper presents a powerful tool to enhance research in education: ‘exploratory portals’, supporting effective storage, sharing and exploration of large sets of research data. The workflow is the following: data are gathered by a research group; they are then classified according to a taxonomy (the one that best fits the group’s research interest; once uploaded in the portal, they can be ‘explored’ via a combination of faceted search (enriched by Boolean operators and data mining techniques. The system can thus answer in a few seconds to sophisticated user’s queries that otherwise would require hours; it can save a session’s results and materials for sharing with other scholars or for further investigation. The paper presents a case study of exploratory portal, dealing with data on (technology-based education. The portal has effectively been used by five different research groups, to run complex investigations of data about technology integration into schools.

  3. Idiopathic non-cirrhotic portal hypertension

    Directory of Open Access Journals (Sweden)

    CHEN Jie

    2013-07-01

    Full Text Available The pathogenesis of idiopathic non-cirrhotic portal hypertension (INCPH remains unknown and the disease is diagnosed by the absence of recognized clinical indicators of cirrhosis and of any other known etiologies of portal hypertension. To promote understanding of this disease, a comprehensive overview of potential etiologies, clinical manifestations, histopathological features, methods of diagnosis and potential differential diagnoses, and outcome of clinical management is presented in this review. In particular, we discuss the findings from INCPH studies and their implications in regards to each of the above-mentioned categories. For example, associations with various comorbidities have suggested a possible immune system component to INCPH development and/or progression. In addition, the common clinical characteristics of patients upon presentation can not only help to recognize disease suspects but may also provide insights into the pathogenesis and prognosis. Finally, prognosis following the various intervention strategies appears to depend mainly on severity of the portal hypertension, as well as its various accompanying complications.

  4. The DIRAC Web Portal 2.0

    Science.gov (United States)

    Mathe, Z.; Casajus Ramo, A.; Lazovsky, N.; Stagni, F.

    2015-12-01

    For many years the DIRAC interware (Distributed Infrastructure with Remote Agent Control) has had a web interface, allowing the users to monitor DIRAC activities and also interact with the system. Since then many new web technologies have emerged, therefore a redesign and a new implementation of the DIRAC Web portal were necessary, taking into account the lessons learnt using the old portal. These new technologies allowed to build a more compact, robust and responsive web interface that enables users to have better control over the whole system while keeping a simple interface. The web framework provides a large set of “applications”, each of which can be used for interacting with various parts of the system. Communities can also create their own set of personalised web applications, and can easily extend already existing ones with a minimal effort. Each user can configure and personalise the view for each application and save it using the DIRAC User Profile service as RESTful state provider, instead of using cookies. The owner of a view can share it with other users or within a user community. Compatibility between different browsers is assured, as well as with mobile versions. In this paper, we present the new DIRAC Web framework as well as the LHCb extension of the DIRAC Web portal.

  5. Grid Portal for Image and Video Processing

    International Nuclear Information System (INIS)

    Dinitrovski, I.; Kakasevski, G.; Buckovska, A.; Loskovska, S.

    2007-01-01

    Users are typically best served by G rid Portals . G rid Portals a re web servers that allow the user to configure or run a class of applications. The server is then given the task of authentication of the user with the Grid and invocation of the required grid services to launch the user's application. PHP is a widely-used general-purpose scripting language that is especially suited for Web development and can be embedded into HTML. PHP is powerful and modern server-side scripting language producing HTML or XML output which easily can be accessed by everyone via web interface (with the browser of your choice) and can execute shell scripts on the server side. The aim of our work is development of Grid portal for image and video processing. The shell scripts contains gLite and globus commands for obtaining proxy certificate, job submission, data management etc. Using this technique we can easily create web interface to the Grid infrastructure. The image and video processing algorithms are implemented in C++ language using various image processing libraries. (Author)

  6. Interventional Radiologic Treatment for Idiopathic Portal Hypertension

    International Nuclear Information System (INIS)

    Hirota, Shozo; Ichikawa, Satoshi; Matsumoto, Shinichi; Motohara, Tomofumi; Fukuda, Tetsuya; Yoshikawa, Takeshi

    1999-01-01

    Purpose: To evaluate the usefulness of interventional radiological treatment for idiopathic portal hypertension. Methods: Between 1995 and 1998, we performed an interventional radiological treatment in five patients with idiopathic portal hypertension, four of whom had refused surgery and one of whom had undergone surgery. Three patients with gastroesophageal varices (GEV) were treated by partial splenic embolization (PSE), one patient with esophageal varices (EV) and massive ascites by transjugular intrahepatic portosytemic shunt (TIPS) and PSE, and one patient with GEV by percutaneous transhepatic obliteration (PTO). Midterm results were analyzed in terms of the effect on esophageal and/or gastric varices. Results: In one woman with severe GEV who underwent three sessions of PSE, there was endoscopic confirmation that the GEV had disappeared. In one man his EV shrunk markedly after two sessions of PSE. In two patients slight reduction of the EV was obtained with one application of PSE combined with endoscopic variceal ligation therapy. PTO for GV in one patient resulted in good control of the varices. All patients have survived for 16-42 months since the first interventional treatment, and varices are well controlled. Conclusion: Interventional radiological treatment is effective for patients with idiopathic portal hypertension, whether or not they have undergone surgery

  7. MRI in patients with portal hypertension (preoperative and postoperative studies). The first 15 cases

    Energy Technology Data Exchange (ETDEWEB)

    Pozzato, A; Cattoni, F; Baldini, U and others

    1987-01-01

    Fifteen patients with portal hypertension were examined by magnetic resonance imaging (MRI) using spin-echo sequences. Sagittal and transaxial images were obtained in all cases. Ten subjects have been evaluated after portosystemic shunt operations (6 portocaval and 4 splenorenal shunts); 5 patients were studied by MRI before shunt placements. Angiographic correlation was obtained in 15 cases. In each of the preoperative examinations, MRI accurately depicted inferior vena cava, portal vein and splenic vein. Shunt patency was documented in 10/10 postoperative studies: portacaval shunts patency was better determined in the transaxial plane while splenorenal shunts were better demonstrted in the sagittal plane. Thus, MRI seems to be an accurate and noninvasive method for detecting portosystemic shunt patency without the use of intravenous contrast media and without patient exposure to radiation.

  8. Transjugular intrahepatic portosystemic shunt in patients with active variceal bleeding due to portal hypertension and portal vein thrombosis

    International Nuclear Information System (INIS)

    Shin, Hyun Woong; Ryeom, Hun Kyu; Lee, Sang Kwon; Lee, Jong Min; Kim, Young Sun; Suh, Kyung Jin; Kim, Tae Hun; Kim, Yong Joo

    1997-01-01

    To evaluate the feasibility and efficacy of transjugular intrahepatic portosystemic shunt (TIPS) in patients with active variceal bleeding due to liver cirrhosis and pre-existing portal vein thrombosis. Of a total of 123 patients who underwent TIPS, 14 patients with intractable variceal bleeding due to portal hypertension and portal vein thrombosis were included in this study. Noncavernomatous portal vein occlusion was seen in eight patients, and complete portal vein occlusion with cavernomatous trans-formation in six. For all patients, the methods used for TIPS placement were the same as those used in patients with patents portal veins. In seven of eight patients with noncavernomatous occlusion, right hepatic vein-right portal vein shunting was performed; in one with knoncavernomatous occlusion, a shunt was created between the right hepatic and left portal vein. In five of six patients with cavernomatous occlusion, the right hepatic and main portal vein were connected via a collateral vein. The procedures were technically successful in all except one patient. Immediate hemostatis was achieved after all technically successful procedures, and no significant complications were encountered. Minor complications were noted in six patients (three biliary tree punctures, one transperitoneal puncture, one splenic vein perforation, one hepatic subcapsular hematoma). TIPS is a technically feasible and hemodynamically effective procedure, even in patients with active variceal bleeding due to cirrhosis and complete portal vein occlusion

  9. Índice de congestão portal e a ocorrência de trombose portal pós-dape Portal congestion and thrombosis after EDS

    Directory of Open Access Journals (Sweden)

    Fabio Gonçalves Ferreira

    2005-08-01

    Full Text Available OBJETIVO: Comparar os dados obtidos pela ultra-sonografia com doppler no pré-operatório de esquistossomóticos submetidos à desconexão ázigo-portal com esplenectomia (DAPE, calculando o índice de congestão portal, e sua correlação com a trombose portal no pós-operatório. MÉTODOS: Foram estudados 65 pacientes submetidos à DAPE por hipertensão portal esquistossomótica com antecedente de hemorragia digestiva, divididos em dois grupos: Grupo A (28 pacientes que não desenvolveram trombose portal pós-operatória e Grupo B (37 pacientes com trombose portal no pós-operatório. Analisaram-se através de ultra-sonografia com doppler no pré-operatório os seguintes parâmetros da veia porta: diâmetro, área, velocidade média de fluxo do sangue, fluxo de sangue, e estabeleceu-se o índice de congestão portal. RESULTADOS: O diâmetro, área e o fluxo da veia porta foram maiores no grupo B (média de 1,52 cm; 1,77 cm² e 2533,12 ml/min em relação ao grupo A (média de 1,33 cm; 1,44 cm² e 1609,03 ml/min com p = 0,03; 0,03 e 0,04 respectivamente. O índice de congestão portal não foi estatisticamente significativo na comparação dos dois grupos (p = 0,07. CONCLUSÃO: O índice de congestão portal obtido no pré-operatório através da ultra-sonografia com doppler não se mostrou preditivo de trombose portal no pós-operatório dos doentes estudados.BACKGROUND: The study compared the preoperative portal vein congestion index estimated by Doppler ultrasound and the postoperative portal vein thrombosis of patients submitted to esophagogastric devascularization and splenectomy (EDS. METHODS: 65 patients with portal hypertension due to schistosomiasis and previous gastrointestinal bleeding submitted to EDS were divided into two groups: GROUP A (28 patients without postoperative portal vein thrombosis and GROUP B (37 patients with postoperative portal vein thrombosis. The following parameters of preoperative Doppler ultrasound of the

  10. TMEM16A regulates portal vein smooth muscle cell proliferation in portal hypertension.

    Science.gov (United States)

    Zeng, Xi; Huang, Ping; Chen, Mingkai; Liu, Shiqian; Wu, Nannan; Wang, Fang; Zhang, Jing

    2018-01-01

    The aim of the present study was to elucidate the effect of transmembrane protein 16A (TMEM16A) on portal vein smooth muscle cell (PVSMC) proliferation associated with portal vein remodeling in portal hypertension (PHT). Sprague-Dawley rats were subjected to bile duct ligation to establish a rat model of liver cirrhosis and PHT. Sham-operated animals served as controls. At 8 weeks after bile duct ligation, the extent of liver fibrosis and the portal vein wall thickness were assessed using hematoxylin-eosin staining. The protein expression levels of TMEM16A, extracellular signal-regulated kinase 1 and 2 (ERK1/2) and phosphorylated ERK1/2 (p-ERK1/2) in the portal vein were detected by immunohistochemistry and western blotting. In vitro , the lentivirus vectors were constructed and transfected into PVSMCs to upregulate the expression of TMEM16A. Isolated rat primary PVSMCs were treated with a small molecule inhibitor of TMEM16A, T16A-inhA01. Cell cycle was detected by flow cytometry. The activity of TMEM16A in the portal vein isolated from bile duct ligated rats was decreased, while the expression level of p-ERK1/2 was increased. However, in vitro , upregulation of TMEM16A promoted the proliferation PVSMCs, while inhibition of TMEM16A channels inhibited the proliferation of PVSMCs. The results indicated that TMEM16A contributes to PVSMCs proliferation in vitro , but in vivo , it may be a negative regulator of cell proliferation influenced by numerous factors.

  11. Transjugular Intrahepatic Portosystemic Shunt for Portal Hypertension in Hepatocellular Carcinoma with Portal Vein Tumor Thrombus.

    Science.gov (United States)

    Qiu, Bin; Li, Kai; Dong, Xiaoqun; Liu, Fu-Quan

    2017-09-01

    In patients with hepatocellular carcinoma (HCC), limited therapeutic options are available for portal hypertension resulted from portal vein tumor thrombus (PVTT). We aimed to determine safety and efficacy of TIPS for treatment of symptomatic portal hypertension in HCC with PVTT. We evaluated clinical characteristics of 95 patients with HCC and PVTT out of 992 patients who underwent TIPS. The primary endpoints included success rate, procedural mortality, serious complications, decrease in portosystemic pressure gradient, and symptom relief. The secondary endpoints included recurrence of portal hypertension, overall survival, adverse events related to treatments for HCC, and quality of life measured by Karnofsky Performance Status Scale (KPS). Success rate of TIPS was 95.8% (91/95), with procedural mortality of 1.1%. Serious complications related to TIPS procedure occurred in 2.1% (2/95) of patients. The symptoms of portal hypertension were well relieved. Variceal bleeding was successfully controlled and terminated in 100% of patients, with a recurrence rate of 39.2% in 12 months. Refractory ascites/hydrothorax was controlled partially or completely in 92.9% of patients during 1 month after TIPS, with a recurrence rate of 17.9% in 12 months. Survival rate at 6, 12, 24, and 36 months was 75.8, 52.7, 26.4, and 3.3%, respectively. No unexpected adverse event related to treatments for HCC was observed. The KPS score was 49 ± 4.5 and 63 ± 4.7 before and 1 month after TIPS, respectively (p portal hypertension in HCC with PVTT.

  12. A Climate Information Portal for Copernicus: a central portal for European climate services?

    Science.gov (United States)

    Juckes, Martin; Swart, Rob; Thysse, Peter; Som de Cerff, Wim; Groot, Annemarie; Bennett, Victoria; Costa, Luis; Lückenkötter, Johannes; Callaghan, Sarah

    2015-04-01

    The FP7 project "Climate Information Portal for Copernicus" (CLIPC) is developing a demonstration portal for the Copernicus Climate Change Service (C3S). This project is one of a suite of FP7 research activities which are administratively independent of Copernicus, focussed on creating the technical and scientific building blocks needed for the service. It is to be expected that at EGU 2015 there will be many presentations describing portals delivering new and innovative ranges of services. It would be unwise to seek to replace all this creative activity with a single portal -- instead CLIPC is designing a portal to make distributed resources more accessible through flexible discovery systems. CLIPC needs to deliver more than a directory of resources: resources need to be presented in common protocols so that users can access multiple datasets. More information about the project objectives is available at www.clipc.eu. The gulf between the climate science communities and the end user communities is a central challenge being addressed in the project. It is important to understand that there is significant diversity and multiple communication barriers within these two sets of communities as well as between them. The CLIPC services must presentation will provide a review of progress towards this ambitious goal, through a discussion of user requirements activities, an overview of the proposed architecture, work on assessing and adjusting model biasses, and a discussion of the climate impact indicators which will be provided through the portal. When looking at the usability of data for the various users, CLIPC will implement a set of services functioning as a "knowledge base" supplying information to users about the data, including definitions of terminology used, quality of datasets, versioning, and user annotations.

  13. Disastrous Portal Vein Embolization Turned into a Successful Intervention

    Energy Technology Data Exchange (ETDEWEB)

    Dobrocky, Tomas, E-mail: tomas.dobrocky@insel.ch [University of Bern, Department of Interventional, Pediatric and Diagnostic Radiology, Inselspital, University Hospital (Switzerland); Kettenbach, Joachim, E-mail: joachim.kettenbach@stpoelten.lknoe.at [Universitätsklinikum St. Pölten-Lilienfeld, Institute of Medical Radiology, Diagnostic, Intervention (Austria); Lopez-Benitez, Ruben, E-mail: Ruben.lopez@insel.ch; Kara, Levent, E-mail: levent.kara@insel.ch [University of Bern, Department of Interventional, Pediatric and Diagnostic Radiology, Inselspital, University Hospital (Switzerland)

    2015-10-15

    Portal vein embolization (PVE) may be performed before hemihepatectomy to increase the volume of future liver remnant (FLR) and to reduce the risk of postoperative liver insufficiency. We report the case of a 71-year-old patient with hilar cholangiocarcinoma undergoing PVE with access from the right portal vein using a mixture of n-butyl-2-cyanoacrylate and ethiodized oil. During the procedure, nontarget embolization of the left portal vein occurred. An aspiration maneuver of the polymerized plug failed; however, the embolus obstructing portal venous flow in the FLR was successfully relocated into the right portal vein while carefully bypassing the plug with a balloon catheter, inflating the balloon, and pulling the plug into the main right portal vein.

  14. Patient activation and use of an electronic patient portal.

    Science.gov (United States)

    Ancker, Jessica S; Osorio, Snezana N; Cheriff, Adam; Cole, Curtis L; Silver, Michael; Kaushal, Rainu

    2015-01-01

    Electronic patient portals give patients access to personal medical data, potentially creating opportunities to improve knowledge, self-efficacy, and engagement in healthcare. The combination of knowledge, self-efficacy, and engagement has been termed activation. Our objective was to assess the relationship between patient activation and outpatient use of a patient portal. Survey. A telephone survey was conducted with 180 patients who had been given access to a portal, 113 of whom used it and 67 of whom did not. The validated patient activation measure (PAM) was administered along with questions about demographics and behaviors. Portal users were no different from nonusers in patient activation. Portal users did have higher education level and more frequent Internet use, and were more likely to have precisely 2 prescription medications than to have more or fewer. Patients who chose to use an electronic patient portal were not more highly activated than nonusers, although they were more educated and more likely to be Internet users.

  15. The stability of liquid-filled matrix ionization chamber electronic portal imaging devices for dosimetry purposes

    International Nuclear Information System (INIS)

    Louwe, R.J.W.; Tielenburg, R.; Ingen, K.M. van; Mijnheer, B.J.; Herk, M.B. van

    2004-01-01

    This study was performed to determine the stability of liquid-filled matrix ionization chamber (LiFi-type) electronic portal imaging devices (EPID) for dosimetric purposes. The short- and long-term stability of the response was investigated, as well as the importance of factors influencing the response (e.g., temperature fluctuations, radiation damage, and the performance of the electronic hardware). It was shown that testing the performance of the electronic hardware as well as the short-term stability of the imagers may reveal the cause of a poor long-term stability of the imager response. In addition, the short-term stability was measured to verify the validity of the fitted dose-response curve immediately after beam startup. The long-term stability of these imagers could be considerably improved by correcting for room temperature fluctuations and gradual changes in response due to radiation damage. As a result, the reproducibility was better than 1% (1 SD) over a period of two years. The results of this study were used to formulate recommendations for a quality control program for portal dosimetry. The effect of such a program was assessed by comparing the results of portal dosimetry and in vivo dosimetry using diodes during the treatment of 31 prostate patients. The improvement of the results for portal dosimetry was consistent with the deviations observed with the reproducibility tests in that particular period. After a correction for the variation in response of the imager, the average difference between the measured and prescribed dose during the treatment of prostate patients was -0.7%±1.5% (1 SD), and -0.6%±1.1% (1 SD) for EPID and diode in vivo dosimetry, respectively. It can be concluded that a high stability of the response can be achieved for this type of EPID by applying a rigorous quality control program

  16. Portal Still Alive and Portal 2: Lessons from Critical Narrative Gaming Pedagogy

    OpenAIRE

    Yamasaki, Lisa Josefina

    2016-01-01

    Due to the increasing popularity of video games in mass media culture, I will be investigating one particular video game series, Portal: Still Alive and Portal 2, and the manner by which players learn from them. After observing that most instructors use these games in physics and math classes, I want to expand more on the way that video games enact a new story-telling feature through experiential means, which also serves a pedagogical function. I assert that players learn from games through...

  17. Gamma and neutron detection modeling in the nuclear detection figure of merit (NDFOM) portal

    International Nuclear Information System (INIS)

    Stroud, Phillip D.; Saeger, Kevin J.

    2009-01-01

    The Nuclear Detection Figure Of Merit (NDFOM) portal is a database of objects and algorithms for evaluating the performance of radiation detectors to detect nuclear material. This paper describes the algorithms used to model the physics and mathematics of radiation detection. As a first-principles end-to-end analysis system, it starts with the representation of the gamma and neutron spectral fluxes, which are computed with the particle and radiation transport code MCNPX. The gamma spectra emitted by uranium, plutonium, and several other materials of interest are described. The impact of shielding and other intervening material is computed by the method of build-up factors. The interaction of radiation with the detector material is computed by a detector response function approach. The construction of detector response function matrices based on MCNPX simulation runs is described in detail. Neutron fluxes are represented in a three group formulation to treat differences in detector sensitivities to thermal, epithermal, and fast neutrons.

  18. Large vehicle portal monitor for perimeter safeguards applications

    International Nuclear Information System (INIS)

    Caldwell, J.T.; Atwater, H.F.; Bernard, W.; Bieri, J.M.; Shunk, E.R.

    1979-01-01

    We have developed a class of vehicle portal monitors based on shielded 4π geometry neutron counting. we have derived and experimentally verified an analytical expression relating the detection sensitivity of the neutron tunnel vehicle portal monitor to four design parameters of the system. For a given number of neutron detectors, this design achieves one or more orders of magnitude improvement in nuclear materials detection sensitivity over previous vehicle portal monitors

  19. Multidetector CT portal venography in evaluation of portosystemic collateral vessels

    International Nuclear Information System (INIS)

    Agarwal, A.; Jain, M.

    2008-01-01

    This essay shows the usefulness of multidetector CT angiography for evaluation of the splenoportal venous system, which is essential in the management of patients with portal hypertension and its complications, such as portal vein thrombosis. By providing scanning with reconstruction of thin axial source images and reformatting into thicker multiplanar reformats, multidetector CT can help to determine the extent and location of portosystemic collateral vessels in patients with portal hypertension and is probably the optimal imaging technique in this setting.

  20. Arachidonic acid metabolites and endothelial dysfunction of portal hypertension.

    Science.gov (United States)

    Sacerdoti, David; Pesce, Paola; Di Pascoli, Marco; Brocco, Silvia; Cecchetto, Lara; Bolognesi, Massimo

    2015-07-01

    Increased resistance to portal flow and increased portal inflow due to mesenteric vasodilatation represent the main factors causing portal hypertension in cirrhosis. Endothelial cell dysfunction, defined as an imbalance between the synthesis, release, and effect of endothelial mediators of vascular tone, inflammation, thrombosis, and angiogenesis, plays a major role in the increase of resistance in portal circulation, in the decrease in the mesenteric one, in the development of collateral circulation. Reduced response to vasodilators in liver sinusoids and increased response in the mesenteric arterioles, and, viceversa, increased response to vasoconstrictors in the portal-sinusoidal circulation and decreased response in the mesenteric arterioles are also relevant to the pathophysiology of portal hypertension. Arachidonic acid (AA) metabolites through the three pathways, cyclooxygenase (COX), lipoxygenase, and cytochrome P450 monooxygenase and epoxygenase, are involved in endothelial dysfunction of portal hypertension. Increased thromboxane-A2 production by liver sinusoidal endothelial cells (LSECs) via increased COX-1 activity/expression, increased leukotriens, increased epoxyeicosatrienoic acids (EETs) (dilators of the peripheral arterial circulation, but vasoconstrictors of the portal-sinusoidal circulation), represent a major component in the increased portal resistance, in the decreased portal response to vasodilators and in the hyper-response to vasoconstrictors. Increased prostacyclin (PGI2) via COX-1 and COX-2 overexpression, and increased EETs/heme-oxygenase-1/K channels/gap junctions (endothelial derived hyperpolarizing factor system) play a major role in mesenteric vasodilatation, hyporeactivity to vasoconstrictors, and hyper-response to vasodilators. EETs, mediators of liver regeneration after hepatectomy and of angiogenesis, may play a role in the development of regenerative nodules and collateral circulation, through stimulation of vascular endothelial

  1. TUX-INTERO: A Portal for secure interoperation of Grids

    OpenAIRE

    Shashi Bhanwar; Seema Bawa

    2010-01-01

    In this paper, we propose TUX-INTERO - a portlet-based Grid portal for integrating existing grid technologies under a common interface and providing reliable services to the users. We have developed a prototype of TUX-INTERO - a grid portal using portlet technology. The paper presents design and development of TUXINTERO. The requirements for the portal, its design and technology choices lead to the utilization of Globus Toolkit as middleware for connecting global resources, SUN N1 GE6 and Con...

  2. Aneurysmal malformation of the extrahepatic portal vein: a case report

    International Nuclear Information System (INIS)

    Lee, Jeong Min; Kang, Sung Soo; Kim, Chong Soo; Han, Hyeun Young

    1999-01-01

    Aneurysmal malformation of the portal vein is a rare entity. To our knowledge, only scattered reports of portal vein aneurysms appear in the literature in English, and there is no previously published report in Korean. We describe a case exhibiting aneurysmal malformation of the extrahepatic portal vein at the hepatic hilum ; the findings demonstrated by ultrasound, CT and angiography are discussed, a review of previously described cases is included

  3. Congenital absence of the portal vein presenting as pulmonary hypertension

    International Nuclear Information System (INIS)

    Jun, Sur Young; Lee, Whal; Cheon, Jung Eun; Kim, Woo Sun; Kim, In One; Yeon, Kyung Mo

    2007-01-01

    Congenital absence of the portal vein (CAPV) is a rare malformation in which intestinal and splenic venous flow bypasses the liver and drains directly into the systemic circulation via a congenital portosystemic shunt. We describe two cases of CAPV presenting as pulmonary hypertension that were initially suspected as primary pulmonary hypertension. However, subsequent ultrasonography and CT detected the absence of a portal vein and the presence of a portosystemic shunt. Pulmonary hypertension is a recognized complication of liver disease and portal hypertension. However, these two cases illustrate that CAPV may result in pulmonary hypertension without liver disease or portal hypertension

  4. Indications for portal pressure measurement in chronic liver disease

    DEFF Research Database (Denmark)

    Hobolth, Lise; Bendtsen, Flemming; Møller, Søren

    2012-01-01

    Portal hypertension leads to development of serious complications such as esophageal varices, ascites, renal and cardiovascular dysfunction. The importance of the degree of portal hypertension has been substantiated within recent years. Measurement of the portal pressure is simple and safe...... and the hepatic venous pressure gradient (HVPG) independently predicts survival and development of complications such as ascites, HCC and bleeding from esophageal varices. Moreover, measurements of HVPG can be used to guide pharmacotherapy for primary and secondary prophylaxis for variceal bleeding. Assessment...... of HVPG should therefore be considered as a part of the general characterization of patients with portal hypertension in departments assessing and treating this condition....

  5. Congenital absence of the portal vein presenting as pulmonary hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Sur Young; Lee, Whal; Cheon, Jung Eun; Kim, Woo Sun; Kim, In One; Yeon, Kyung Mo [Seoul National University Hospital, Seoul (Korea, Republic of)

    2007-11-15

    Congenital absence of the portal vein (CAPV) is a rare malformation in which intestinal and splenic venous flow bypasses the liver and drains directly into the systemic circulation via a congenital portosystemic shunt. We describe two cases of CAPV presenting as pulmonary hypertension that were initially suspected as primary pulmonary hypertension. However, subsequent ultrasonography and CT detected the absence of a portal vein and the presence of a portosystemic shunt. Pulmonary hypertension is a recognized complication of liver disease and portal hypertension. However, these two cases illustrate that CAPV may result in pulmonary hypertension without liver disease or portal hypertension.

  6. Clinical value of liver and spleen shear wave velocity in predicting the prognosis of patients with portal hypertension.

    Science.gov (United States)

    Zhang, Yan; Mao, Da-Feng; Zhang, Mei-Wu; Fan, Xiao-Xiang

    2017-12-07

    To explore the relationship of liver and spleen shear wave velocity in patients with liver cirrhosis combined with portal hypertension, and assess the value of liver and spleen shear wave velocity in predicting the prognosis of patients with portal hypertension. All 67 patients with liver cirrhosis diagnosed as portal hypertension by hepatic venous pressure gradient in our hospital from June 2014 to December 2014 were enrolled into this study. The baseline information of these patients was recorded. Furthermore, 67 patients were followed-up at 20 mo after treatment, and liver and spleen shear wave velocity were measured by acoustic radiation force impulse at the 1 st week, 3 rd month and 9 th month after treatment. Patients with favorable prognosis were assigned into the favorable prognosis group, while patients with unfavorable prognosis were assigned into the unfavorable prognosis group. The variation and difference in liver and spleen shear wave velocity in these two groups were analyzed by repeated measurement analysis of variance. Meanwhile, in order to evaluate the effect of liver and spleen shear wave velocity on the prognosis of patients with portal hypertension, Cox's proportional hazard regression model analysis was applied. The ability of those factors in predicting the prognosis of patients with portal hypertension was calculated through receiver operating characteristic (ROC) curves. The liver and spleen shear wave velocity in the favorable prognosis group revealed a clear decline, while those in the unfavorable prognosis group revealed an increasing tendency at different time points. Furthermore, liver and spleen shear wave velocity was higher in the unfavorable prognosis group, compared with the favorable prognosis group; the differences were statistically significant ( P portal hypertension was significantly affected by spleen hardness at the 3 rd month after treatment [relative risk (RR) = 3.481]. At the 9 th month after treatment, the prognosis

  7. Multidetector row computed tomography of acute pancreatitis: Utility of single portal phase CT scan in short-term follow up

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Yongwonn [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of); Park, Hee Sun, E-mail: heesun.park@gmail.com [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of); Kim, Young Jun; Jung, Sung Il; Jeon, Hae Jeong [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of)

    2012-08-15

    analysis, there was no significant difference between the three image sets for both radiologists. However, when only the patients having pancreatic necrosis (n = 13) was separately analyzed, significant differences were observed between the unenhanced and portal phase scan (P = 0.04, for radiologist 1), or unenhanced and dual phase scan (P = 0.013, for radiologist 2). Conclusion: For short-term follow up imaging in assessment of patients with acute pancreatitis, single portal phase CT images without adding unenhanced or arterial phase images provide sufficient information, and thereby reduce radiation exposure.

  8. The influence of culture on enterprise portal design in a global environment

    NARCIS (Netherlands)

    Feng, Xiuzhen; Ehrenhard, Michel Léon; Hicks, Jeff; Hou, Yibin; Khosrow-Pour, M.

    2007-01-01

    Enterprise portals collect and synthesize information from various systems to deliver personalized and highly relevant information to suppliers, customers and employees. While enterprise portal design and portal applications have been widely discussed in the literature, the implications that arise

  9. Portal vein stenting for delayed jejunal varix bleeding associated with portal venous occlusion after hepatoiliary and pancreatic surgery

    Energy Technology Data Exchange (ETDEWEB)

    Hyun, Dong Ho; Park, Kwang Bo; Cho, Sung Ki; Park, Hong Suk; Shin, Sung Wook; Choo, Sung Wook; Do, Young Soo; Choo, In Wook; Choi, Dong Wook [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2017-09-15

    The study aimed to describe portal stenting for postoperative portal occlusion with delayed (≥ 3 months) variceal bleeding in the afferent jejunal loop. Eleven consecutive patients (age range, 2–79 years; eight men and three women) who underwent portal stenting between April 2009 and December 2015 were included in the study. Preoperative medical history and the postoperative clinical course were reviewed. Characteristics of portal occlusion and details of procedures were also investigated. Technical success, treatment efficacy (defined as disappearance of jejunal varix on follow-up CT), and clinical success were analyzed. Primary stent patency rate was plotted using the Kaplan-Meier method. All patients underwent hepatobiliary-pancreatic cancer surgery except two children with liver transplantation for biliary atresia. Portal occlusion was caused by benign postoperative change (n = 6) and local tumor recurrence (n = 5). Variceal bleeding occurred at 27 months (4 to 72 months) and portal stenting was performed at 37 months (4 to 121 months), on average, postoperatively. Technical success, treatment efficacy, and clinical success rates were 90.9, 100, and 81.8%, respectively. The primary patency rate of portal stent was 88.9% during the mean follow-up period of 9 months. Neither procedure-related complication nor mortality occurred. Interventional portal stenting is an effective treatment for delayed jejunal variceal bleeding due to portal occlusion after hepatobiliary-pancreatic surgery.

  10. Portal vein stenting for delayed jejunal varix bleeding associated with portal venous occlusion after hepatoiliary and pancreatic surgery

    International Nuclear Information System (INIS)

    Hyun, Dong Ho; Park, Kwang Bo; Cho, Sung Ki; Park, Hong Suk; Shin, Sung Wook; Choo, Sung Wook; Do, Young Soo; Choo, In Wook; Choi, Dong Wook

    2017-01-01

    The study aimed to describe portal stenting for postoperative portal occlusion with delayed (≥ 3 months) variceal bleeding in the afferent jejunal loop. Eleven consecutive patients (age range, 2–79 years; eight men and three women) who underwent portal stenting between April 2009 and December 2015 were included in the study. Preoperative medical history and the postoperative clinical course were reviewed. Characteristics of portal occlusion and details of procedures were also investigated. Technical success, treatment efficacy (defined as disappearance of jejunal varix on follow-up CT), and clinical success were analyzed. Primary stent patency rate was plotted using the Kaplan-Meier method. All patients underwent hepatobiliary-pancreatic cancer surgery except two children with liver transplantation for biliary atresia. Portal occlusion was caused by benign postoperative change (n = 6) and local tumor recurrence (n = 5). Variceal bleeding occurred at 27 months (4 to 72 months) and portal stenting was performed at 37 months (4 to 121 months), on average, postoperatively. Technical success, treatment efficacy, and clinical success rates were 90.9, 100, and 81.8%, respectively. The primary patency rate of portal stent was 88.9% during the mean follow-up period of 9 months. Neither procedure-related complication nor mortality occurred. Interventional portal stenting is an effective treatment for delayed jejunal variceal bleeding due to portal occlusion after hepatobiliary-pancreatic surgery

  11. A novel canine model of portal vein stenosis plus thioacetamide administration-induced cirrhotic portal hypertension with hypersplenism.

    Science.gov (United States)

    Lin, Dexin; Wu, Xianbin; Ji, Xiaoke; Zhang, Qiyu; Lin, YuanWei; Chen, WeiJian; Jin, Wangxun; Deng, Liming; Chen, Yunzhi; Chen, Bicheng; Li, Jianmin

    2012-01-01

    Current large animal models that could closely resemble the typical features of cirrhotic portal hypertension in human have not been well established. Thus, we aimed to develop and describe a reliable and reproducible canine cirrhosis model of portal hypertension. A total of 30 mongrel dogs were randomly divided into four groups: 1 (control; n = 5), 2 (portal vein stenosis [PVS]; n = 5], 3 (thioacetamide [TAA]; n = 5), and 4 (PVS plus TAA; n = 15). After 4-months modeling period, liver and spleen CT perfusion, abdominal CT scans, portal hemodynamics, gastroscopy, hepatic function, blood routine, the bone marrow, liver, and spleen histology were studied. The animals in group 2 (PVS) developed extrahepatic portosystemic collateral circulation, particularly esophageal varices, without hepatic cirrhosis and portal hypertension. Animals from group 3 (TAA) presented mild cirrhosis and portal hypertension without significant symptoms of esophageal varices and hypersplenism. In contrast, animals from group 4 (PVS + TAA) showed well-developed micronodular and macronodular cirrhosis, associated with significant portal hypertension and hypersplenism. The combination of PVS and TAA represents a novel, reliable, and reproducible canine cirrhosis model of portal hypertension, which is associated with the typical characteristics of portal hypertension, including hypersplenism.

  12. Novel Rat Model of Repetitive Portal Venous Embolization Mimicking Human Non-Cirrhotic Idiopathic Portal Hypertension.

    Science.gov (United States)

    Klein, Sabine; Hinüber, Christian; Hittatiya, Kanishka; Schierwagen, Robert; Uschner, Frank Erhard; Strassburg, Christian P; Fischer, Hans-Peter; Spengler, Ulrich; Trebicka, Jonel

    2016-01-01

    Non-cirrhotic idiopathic portal hypertension (NCIPH) is characterized by splenomegaly, anemia and portal hypertension, while liver function is preserved. However, no animal models have been established yet. This study assessed a rat model of NCIPH and characterized the hemodynamics, and compared it to human NCIPH. Portal pressure (PP) was measured invasively and coloured microspheres were injected in the ileocecal vein in rats. This procedure was performed weekly for 3 weeks (weekly embolization). Rats without and with single embolization served as controls. After four weeks (one week after last embolization), hemodynamics were investigated, hepatic fibrosis and accumulation of myofibroblasts were analysed. General characteristics, laboratory analyses and liver histology were collected in patients with NCIPH. Weekly embolization induced a hyperdynamic circulation, with increased PP. The mesenteric flow and hepatic hydroxyproline content was significantly higher in weekly embolized compared to single embolized rats (mesenteric flow +54.1%, hydroxyproline +41.7%). Mesenteric blood flow and shunt volumes increased, whereas splanchnic vascular resistance was decreased in the weekly embolization group. Fibrotic markers αSMA and Desmin were upregulated in weekly embolized rats. This study establishes a model using repetitive embolization via portal veins, comparable with human NCIPH and may serve to test new therapies.

  13. Total hepatofugal portal blood flow in cirrhosis demonstrated by transhepatic portography

    International Nuclear Information System (INIS)

    Burcharth, F.; Aagaard, J.; Herlev Hospital

    1988-01-01

    We investigated 108 patients with cirrhosis of the liver and portal hypertension by percutaneous transhepatic portography to demonstrate the occurrence and frequency of total hepatofugal portal blood flow. Sixteen patients (14.8%) had a total hepatofugal portal blood flow. The aetiology of portal hypertension and the portal pressure did not differ from that in the group of patients with hepatopetal portal blood flow. A significantly higher percentage of patients in the group with hepatofugal flow had gastro-oesophageal varices (P [de

  14. Development of Geometrical Quality Control Real-time Analysis Program using an Electronic Portal Imaging

    International Nuclear Information System (INIS)

    Lee, Sang Rok; Jung, Kyung Yong; Jang, Min Sun; Lee, Byung Gu; Kwon, Young Ho

    2012-01-01

    To develop a geometrical quality control real-time analysis program using an electronic portal imaging to replace film evaluation method. A geometrical quality control item was established with the Eclipse treatment planning system (Version 8.1, Varian, USA) after the Electronic Portal Imaging Device (EPID) took care of the problems occurring from the fixed substructure of the linear accelerator (CL-iX, Varian, USA). Electronic portal image (single exposure before plan) was created at the treatment room's 4DTC (Version 10.2, Varian, USA) and a beam was irradiated in accordance with each item. The gaining the entire electronic portal imaging at the Off-line review and was evaluated by a self-developed geometrical quality control real-time analysis program. As for evaluation methods, the intra-fraction error was analyzed by executing 5 times in a row under identical conditions and procedures on the same day, and in order to confirm the infer-fraction error, it was executed for 10 days under identical conditions of all procedures and was compared with the film evaluation method using an Iso-align quality control device. Measurement and analysis time was measured by sorting the time into from the device setup to data achievement and the time amount after the time until the completion of analysis and the convenience of the users and execution processes were compared. The intra-fraction error values for each average 0.1, 0.2, 0.3, 0.2 mm at light-radiation field coincidence, collimator rotation axis, couch rotation axis and gantry rotation axis. By checking the infer-fraction error through 10 days of continuous quality control, the error values obtained were average 1.7, 1.4, 0.7, 1.1 mm for each item. Also, the measurement times were average 36 minutes, 15 minutes for the film evaluation method and electronic portal imaging system, and the analysis times were average 30 minutes, 22 minutes. When conducting a geometrical quality control using an electronic portal imaging

  15. Basic dose response of fluorescent screen-based portal imaging device

    International Nuclear Information System (INIS)

    Yeo, In Hwan; Yonannes, Yonas; Zhu, Yunping

    1999-01-01

    The purpose of this study is to investigate fundamental aspects of the dose response of fluorescent screen-based electronic portal imaging devices (EPIDs). We acquired scanned signal across portal planes as we varied the radiation that entered the EPID by changing the thickness and anatomy of the phantom as well as the air gap between the phantom and the EPID. In addition, we simulated the relative contribution of the scintillation light signal in the EPID system. We have shown that the dose profile across portal planes is a function of the air gap and phantom thickness. We have also found that depending on the density change within the phantom geometry, errors associated with dose response based on the EPID scan can be as high as 7%. We also found that scintillation light scattering within the EPID system is an important source of error. This study revealed and demonstrated fundamental characteristics of dose response of EPID, as relative to that of ion chambers. This study showed that EPID based on fluorescent screen cannot be an accurate dosimetry system

  16. Assessment of the influence of a carbon fiber tabletop on portal imaging

    International Nuclear Information System (INIS)

    Misiarz, Agnieszka; Krawczyk, Paweł; Swat, Kaja; Andrasiak, Michał

    2013-01-01

    the best image quality parameters and the lowest influence of the carbon fiber tabletop. The insertion of the tabletop causes quality factors change, as can be expected, but these changes can be offset by software and have negligible influence for image quality. Measurements were made in the project: Accelerators and Detectors. Development of dedicated systems based on accelerators and detectors of ionizing radiation for medical therapy and in detection of hazardous materials and toxic wastes (Project co-financed by European Union via European Regional Development Fund). -- Highlights: ► We make investigation of image quality factors changes caused by a carbon-fiber tabletop. ► We make images with and without tabletop and various portal—isocenter distances. ► We find tabletop beam attenuation in vertical direction—3.4%. ► We find best phantom (patient)—portal distance for taking portal image—40 cm. ► We find that the presence of tabletop have negligible influence for image quality

  17. Assessment of the influence of a carbon fiber tabletop on portal imaging

    Energy Technology Data Exchange (ETDEWEB)

    Misiarz, Agnieszka, E-mail: agnieszka.misiarz@ncbj.gov.pl [National Centre for Nuclear Research, 05-400 Swierk, Otwock (Poland); Krawczyk, Paweł; Swat, Kaja; Andrasiak, Michał [National Centre for Nuclear Research, 05-400 Swierk, Otwock (Poland)

    2013-06-21

    observes the best image quality parameters and the lowest influence of the carbon fiber tabletop. The insertion of the tabletop causes quality factors change, as can be expected, but these changes can be offset by software and have negligible influence for image quality. Measurements were made in the project: Accelerators and Detectors. Development of dedicated systems based on accelerators and detectors of ionizing radiation for medical therapy and in detection of hazardous materials and toxic wastes (Project co-financed by European Union via European Regional Development Fund). -- Highlights: ► We make investigation of image quality factors changes caused by a carbon-fiber tabletop. ► We make images with and without tabletop and various portal—isocenter distances. ► We find tabletop beam attenuation in vertical direction—3.4%. ► We find best phantom (patient)—portal distance for taking portal image—40 cm. ► We find that the presence of tabletop have negligible influence for image quality.

  18. Endovascular management for significant iatrogenic portal vein bleeding.

    Science.gov (United States)

    Kim, Jong Woo; Shin, Ji Hoon; Park, Jonathan K; Yoon, Hyun-Ki; Ko, Gi-Young; Gwon, Dong Il; Kim, Jin Hyoung; Sung, Kyu-Bo

    2017-11-01

    Background Despite conservative treatment, hemorrhage from an intrahepatic branch of the portal vein can cause hemodynamic instability requiring urgent intervention. Purpose To retrospectively report the outcomes of hemodynamically significant portal vein bleeding after endovascular management. Material and Methods During a period of 15 years, four patients (2 men, 2 women; median age, 70.5 years) underwent angiography and embolization for iatrogenic portal vein bleeding. Causes of hemorrhage, angiographic findings, endovascular treatment, and complications were reported. Results Portal vein bleeding occurred after percutaneous liver biopsy (n = 2), percutaneous radiofrequency ablation (n = 1), and percutaneous cholecystostomy (n = 1). The median time interval between angiography and percutaneous procedure was 5 h (range, 4-240 h). Common hepatic angiograms including indirect mesenteric portograms showed active portal vein bleeding into the peritoneal cavity with (n = 1) or without (n = 2) an arterioportal (AP) fistula, and portal vein pseudoaneurysm alone with an AP fistula (n = 1). Successful transcatheter arterial embolization (n = 2) or percutaneous transhepatic portal vein embolization (n = 2) was performed. Embolic materials were n-butyl cyanoacrylate alone (n = 2) or in combination with gelatin sponge particles and coils (n = 2). There were no major treatment-related complications or patient mortality within 30 days. Conclusion Patients with symptomatic or life-threatening portal vein bleeding following liver-penetrating procedures can successfully be managed with embolization.

  19. Idiopathic non-cirrhotic portal hypertension: a review

    NARCIS (Netherlands)

    Schouten, Jeoffrey N. L.; Verheij, Joanne; Seijo, Susana

    2015-01-01

    Idiopathic non-cirrhotic portal hypertension (INCPH) is a rare disease characterized of intrahepatic portal hypertension in the absence of cirrhosis or other causes of liver disease and splanchnic venous thrombosis. The etiology of INCPH can be classified in five categories: 1) immunological

  20. Transhepatic course of the portal vein with subcapsular ramification

    Energy Technology Data Exchange (ETDEWEB)

    Goebel, N

    1985-06-01

    In a patient, investigated for uterine carcinoma, CT of the liver showed an anomalous course of a large portal vein, which traversed the liver and divided under the ventrolateral liver capsule in its branches. There were no signs of portal hypertension.

  1. Pathology of idiopathic non-cirrhotic portal hypertension.

    Science.gov (United States)

    Guido, Maria; Sarcognato, Samantha; Sacchi, Diana; Colloredo, Guido

    2018-04-12

    Idiopathic non-cirrhotic portal hypertension is an under-recognized vascular liver disease of unknown etiology, characterized by clinical signs of portal hypertension in the absence of cirrhosis. By definition, any disorder known to cause portal hypertension in the absence of cirrhosis and any cause of chronic liver disease must be excluded to make a diagnosis of idiopathic non-cirrhotic portal hypertension. However, the diagnosis is often difficult because the disease resembles cirrhosis and there is no gold standard test. Liver biopsy is an essential tool: it is able to exclude cirrhosis and other causes of portal hypertension and it allows the identification of the characteristic lesions. Nonetheless, the histological diagnosis of idiopathic non-cirrhotic portal hypertension is not always straightforward, in particular by needle biopsy samples, because there is no pathognomonic lesion, but rather a variety of vascular changes which are unevenly distributed, very subtle, and not all necessarily identified in a single specimen. Pathologists should be able to recognize several patterns of injury, involving portal/periportal areas as well as parenchymal structures.The histological features of idiopathic non-cirrhotic portal hypertension are described in this review, focusing on their interpretation in needle biopsy specimens.

  2. Tracks: The New York City Rat Information Portal

    Centers for Disease Control (CDC) Podcasts

    This podcast, featuring Daniel Kass, Acting Deputy Commissioner of Environmental Health for the New York City (NYC) Department of Health and Mental Hygiene, provides information about the NYC Rat Information Portal. It details the background and uses of the Rat Portal, as well as next steps for the NYC Environmental Public Health Tracking Program.

  3. Intrahepatic portal hypertension secondary to metastatic carcinoma of the prostate.

    Science.gov (United States)

    Attila, Tan; Datta, Milton W; Sudakoff, Gary; Abu-Hajir, Majed; Massey, Benson T

    2007-02-01

    While the liver is a common site of metastasis, tumor metastases are not a common cause of portal hypertension. We report a case of a patient with symptomatic portal hypertension due to diffuse metastatic prostate carcinoma infiltration of liver parenchyma that was not appreciated with routine imaging.

  4. Improving image quality in portal venography with spectral CT imaging

    International Nuclear Information System (INIS)

    Zhao, Li-qin; He, Wen; Li, Jian-ying; Chen, Jiang-hong; Wang, Ke-yang; Tan, Li

    2012-01-01

    Objective: To investigate the effect of energy spectral CT on the image quality of CT portal venography in cirrhosis patients. Materials and methods: 30 portal hypertension patients underwent spectral CT examination using a single-tube, fast dual tube voltage switching technique. 101 sets of monochromatic images were generated from 40 keV to 140 keV. Image noise and contrast-to-noise ratio (CNR) for portal veins from the monochromatic images were measured. An optimal monochromatic image set was selected for obtaining the best CNR for portal veins. The image noise and CNR of the intra-hepatic portal vein and extra-hepatic main stem at the selected monochromatic level were compared with those from the conventional polychromatic images. Image quality was also assessed and compared. Results: The monochromatic images at 51 keV were found to provide the best CNR for both the intra-hepatic and extra-hepatic portal veins. At this energy level, the monochromatic images had about 100% higher CNR than the polychromatic images with a moderate 30% noise increase. The qualitative image quality assessment was also statistically higher with monochromatic images at 51 keV. Conclusion: Monochromatic images at 51 keV for CT portal venography could improve CNR for displaying hepatic portal veins and improve the overall image quality.

  5. Meaningful Use of a Confidential Adolescent Patient Portal.

    Science.gov (United States)

    Thompson, Lindsay A; Martinko, Thomas; Budd, Pamela; Mercado, Rebeccah; Schentrup, Anzeela M

    2016-02-01

    To design and evaluate the usage of an adolescent patient portal specifically adapted for adolescent health care needs that also satisfied institutional meaningful use guidelines regarding electronic health records. Key stakeholders at one academic health care center adopted an online portal and opted to designate a patient portal specifically for adolescents to maximize confidentiality in compliance with state privacy laws. This study analyzed aggregate electronic health record data of adolescents' (ages 12-17.9 years) uptake, usage, and functionality of this portal and compared it to parent portal usage for younger children (ages 0-11 years). Differences in means were calculated using paired t tests. The portal was used similarly between parents of young children and adolescents, with almost 1,000 enrollees in each group from September 1, 2012 to March 31, 2015. There were no gender differences in enrollment. Adolescents were less likely than parents of younger children to review appointments (73% vs. 85%), laboratory tests (67% vs. 79%), problem lists (40% vs. 78%), or allergies (45% vs. 77%, all p values adolescents sent 1,397 confidential messages. Institutional decisions for implementing meaningful use requirements can align with goals of adolescent health. Patient portals can enhance adolescent health care quality and adolescents readily use a confidential portal. Implementation of meaningful use requirements should be checked against adolescent health care needs to maximize confidentiality and promote health communication. Copyright © 2016 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  6. Continued Use of a Chinese Online Portal: An Empirical Study

    Science.gov (United States)

    Shih, Hung-Pin

    2008-01-01

    The evolution of the internet has made online portals a popular means of surfing the internet. In internet commerce, understanding the post-adoption behaviour of users of online portals can help enterprises to attract new users and retain existing customers. For predicting continued use intentions, this empirical study focused on applying and…

  7. An Analysis of Knowledge Management Mechanisms in Healthcare Portals

    Science.gov (United States)

    Lee, Chei Sian; Goh, Dion Hoe-Lian; Chua, Alton Y. K.

    2010-01-01

    Healthcare portals are becoming increasingly popular with Internet users since they play an important role in supporting interaction between individuals and healthcare organizations with a Web presence. Additionally, many of these organizations make use of knowledge management mechanisms on their healthcare portals to manage the abundance of…

  8. Measuring Campus Portal Effectiveness and the Contributing Factors

    Science.gov (United States)

    Masrek, Mohamad Noorman bin

    2007-01-01

    Purpose: The purpose of the paper is to evaluate the effectiveness or success of universities' portal implementation from the perspective of students as users. Adopting the model developed by Delone and McLean, portal effectiveness is defined as being composed of information quality, systems quality and service quality. In addition, the paper also…

  9. Enviroportal.sk - information portal about the environment

    International Nuclear Information System (INIS)

    Navratil, R.; Kmet, M.

    2005-01-01

    In this presentation author deals with history, conception and exploitation of information portal about environment in the Slovak Republic. This portal - Enviroportal.sk was introduced into service in testing operation in April 2005. Perspectives of Enviroportal.sk are discussed

  10. Portal vein thrombosis after splenectomy for beta-thalassemia major

    International Nuclear Information System (INIS)

    Al-Hawsawi, Zakaria M.; Tarawah, Ahmed M.; Hassan, Ruhul Amin A.; Haouimi, Ammar S.

    2004-01-01

    Portal vein thrombosis is a recognized complication after splenectomy for beta-thalassemia major due to the chronic hypercoagulable state which has been recognized to exist in childhood thalassemia and contribute to thromboembolic events. We reporting one patient with beta-thalassemia major developed portal vein thrombosis following splenectomy. (author)

  11. Portal: Your Door to World Languages and Cultures

    Science.gov (United States)

    Elliott, Don; Lawton, Rachele

    2009-01-01

    Portal: Your Door to World Languages and Cultures was a series of public cultural events, in a variety of formats, created through a new partnership between the credit and continuing education (noncredit) foreign language programs at the Community College of Baltimore County (CCBC). Portal was designed to cultivate interest in foreign languages…

  12. Improving image quality in portal venography with spectral CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Li-qin, E-mail: zhaolqzr@sohu.com [Department of Radiology, Beijing Friendship Hospital Affiliated to Capital Medical University, Beijing,100050 (China); He, Wen, E-mail: hewen1724@sina.com [Department of Radiology, Beijing Friendship Hospital Affiliated to Capital Medical University, Beijing,100050 (China); Li, Jian-ying, E-mail: jianying.li@med.ge.com [CT Advanced Application and Research, GE Healthcare, 100176 China (China); Chen, Jiang-hong, E-mail: chenjianghong1973@hotmail.com [Department of Radiology, Beijing Friendship Hospital Affiliated to Capital Medical University, Beijing,100050 (China); Wang, Ke-yang, E-mail: ke7ke@sina.com [Department of Radiology, Beijing Friendship Hospital Affiliated to Capital Medical University, Beijing,100050 (China); Tan, Li, E-mail: Litan@ge.com [CT product, GE Healthcare, 100176 China (China)

    2012-08-15

    Objective: To investigate the effect of energy spectral CT on the image quality of CT portal venography in cirrhosis patients. Materials and methods: 30 portal hypertension patients underwent spectral CT examination using a single-tube, fast dual tube voltage switching technique. 101 sets of monochromatic images were generated from 40 keV to 140 keV. Image noise and contrast-to-noise ratio (CNR) for portal veins from the monochromatic images were measured. An optimal monochromatic image set was selected for obtaining the best CNR for portal veins. The image noise and CNR of the intra-hepatic portal vein and extra-hepatic main stem at the selected monochromatic level were compared with those from the conventional polychromatic images. Image quality was also assessed and compared. Results: The monochromatic images at 51 keV were found to provide the best CNR for both the intra-hepatic and extra-hepatic portal veins. At this energy level, the monochromatic images had about 100% higher CNR than the polychromatic images with a moderate 30% noise increase. The qualitative image quality assessment was also statistically higher with monochromatic images at 51 keV. Conclusion: Monochromatic images at 51 keV for CT portal venography could improve CNR for displaying hepatic portal veins and improve the overall image quality.

  13. Managing a portal of digital web resources by content syndication

    NARCIS (Netherlands)

    van der Vet, P.E.; Hofmann, Martin; Huibers, Theo W.C.; Roosendaal, Hans E.; de Bra, P.

    2003-01-01

    As users become more accustomed to continuous Internet access, they will have less patience with the offering of disparate resources. A new generation of portals is being designed that aids users in navigating resource space and in processing the data they retrieved. Such portals offer added value

  14. questions as engagement strategies in nigerian job portals online

    African Journals Online (AJOL)

    rotimi

    2012-09-13

    Sep 13, 2012 ... Key words: questions, engagement strategy, job portal, Nigeria, unemployment .... Job portals offer different services, such as ..... softer disciplines (philosophy, sociology, applied linguistics and marketing) than the .... constructed based on a hypothetical case and used to bring readers into an imaginary.

  15. Angiographic diagnosis of the prehepatic portal hypertension

    International Nuclear Information System (INIS)

    Carnevali, G.; Brambilla, G.

    1981-01-01

    After the experience gained in the examination of more than 400 patients with portal hypertension, one can say that thrombosis is a factor not to be neglected. It appeared in 25% of all cases, in 50% of all cases as a cause of liver cirrhosis. The representation of the vena coeliaca mesentenica is essential for a reliable detection of thrombosis. Splenoportography is less frequently applied due to the known contraindications and is restricted to more demanding and complex problems. The detection of thrombotic changes is also important because such areas prohibit surgical measures such as by-passes. Also important is the preventive discovery of a portal thrombosis in the course of a complicated, bleeding liver cirrhosis. A pre-operative angiographic diagnosis is necessary in planned portocaval shunt procedures of cirrholic liver alterations. The surgeon has to know beforehand whether pyle thrombosis can be excluded or detected. In the latter case, a thrombotectomy has to be performed, which, however, does not impede good treatment results. (orig./MG) [de

  16. Angiographic diagnosis of the prehepatic portal hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Carnevali, G; Brambilla, G

    1981-01-01

    After the experience gained in the examination of more than 400 patients with portal hypertension, one can say that thrombosis is a factor not to be neglected. It appeared in 25% of all cases and in 50% of all cases as a cause of liver cirrhosis. The representation of the vena coeliaca mesentenica is essential for a reliable detection of thrombosis. Splenoportography is less frequently applied due to the known contraindications and is restricted to more demanding and complex problems. The detection of thrombotic changes is also important because such areas prohibit surgical measures such as by-passes. Also important is the preventive discovery of a portal thrombosis in the course of a complicated, bleeding liver cirrhosis. A pre-operative angiographic diagnosis is necessary in planned portocaval shunt procedures of cirrholic liver alterations. The surgeon has to know beforehand whether pyle thrombosis can be excluded or detected. In the latter case, a thrombotectomy has to be performed, which, however, does not impede good treatment results.

  17. The Anatomy of a Grid portal

    International Nuclear Information System (INIS)

    Licari, Daniele; Calzolari, Federico

    2011-01-01

    In this paper we introduce a new way to deal with Grid portals referring to our implementation. L-GRID is a light portal to access the EGEE/EGI Grid infrastructure via Web, allowing users to submit their jobs from a common Web browser in a few minutes, without any knowledge about the Grid infrastructure. It provides the control over the complete lifecycle of a Grid Job, from its submission and status monitoring, to the output retrieval. The system, implemented as client-server architecture, is based on the Globus Grid middleware. The client side application is based on a java applet; the server relies on a Globus User Interface. There is no need of user registration on the server side, and the user needs only his own X.509 personal certificate. The system is user-friendly, secure (it uses SSL protocol, mechanism for dynamic delegation and identity creation in public key infrastructures), highly customizable, open source, and easy to install. The X.509 personal certificate does not get out from the local machine. It allows to reduce the time spent for the job submission, granting at the same time a higher efficiency and a better security level in proxy delegation and management.

  18. A web portal for hydrodynamical, cosmological simulations

    Science.gov (United States)

    Ragagnin, A.; Dolag, K.; Biffi, V.; Cadolle Bel, M.; Hammer, N. J.; Krukau, A.; Petkova, M.; Steinborn, D.

    2017-07-01

    This article describes a data centre hosting a web portal for accessing and sharing the output of large, cosmological, hydro-dynamical simulations with a broad scientific community. It also allows users to receive related scientific data products by directly processing the raw simulation data on a remote computing cluster. The data centre has a multi-layer structure: a web portal, a job control layer, a computing cluster and a HPC storage system. The outer layer enables users to choose an object from the simulations. Objects can be selected by visually inspecting 2D maps of the simulation data, by performing highly compounded and elaborated queries or graphically by plotting arbitrary combinations of properties. The user can run analysis tools on a chosen object. These services allow users to run analysis tools on the raw simulation data. The job control layer is responsible for handling and performing the analysis jobs, which are executed on a computing cluster. The innermost layer is formed by a HPC storage system which hosts the large, raw simulation data. The following services are available for the users: (I) CLUSTERINSPECT visualizes properties of member galaxies of a selected galaxy cluster; (II) SIMCUT returns the raw data of a sub-volume around a selected object from a simulation, containing all the original, hydro-dynamical quantities; (III) SMAC creates idealized 2D maps of various, physical quantities and observables of a selected object; (IV) PHOX generates virtual X-ray observations with specifications of various current and upcoming instruments.

  19. The Anatomy of a Grid portal

    Science.gov (United States)

    Licari, Daniele; Calzolari, Federico

    2011-12-01

    In this paper we introduce a new way to deal with Grid portals referring to our implementation. L-GRID is a light portal to access the EGEE/EGI Grid infrastructure via Web, allowing users to submit their jobs from a common Web browser in a few minutes, without any knowledge about the Grid infrastructure. It provides the control over the complete lifecycle of a Grid Job, from its submission and status monitoring, to the output retrieval. The system, implemented as client-server architecture, is based on the Globus Grid middleware. The client side application is based on a java applet; the server relies on a Globus User Interface. There is no need of user registration on the server side, and the user needs only his own X.509 personal certificate. The system is user-friendly, secure (it uses SSL protocol, mechanism for dynamic delegation and identity creation in public key infrastructures), highly customizable, open source, and easy to install. The X.509 personal certificate does not get out from the local machine. It allows to reduce the time spent for the job submission, granting at the same time a higher efficiency and a better security level in proxy delegation and management.

  20. Perturbative unitarity constraints on gauge portals

    Science.gov (United States)

    El Hedri, Sonia; Shepherd, William; Walker, Devin G. E.

    2017-12-01

    Dark matter that was once in thermal equilibrium with the Standard Model is generally prohibited from obtaining all of its mass from the electroweak phase transition. This implies a new scale of physics and mediator particles to facilitate dark matter annihilation. In this work, we focus on dark matter that annihilates through a generic gauge boson portal. We show how partial wave unitarity places upper bounds on the dark gauge boson, dark Higgs and dark matter masses. Outside of well-defined fine-tuned regions, we find an upper bound of 9 TeV for the dark matter mass when the dark Higgs and dark gauge bosons both facilitate the dark matter annihilations. In this scenario, the upper bound on the dark Higgs and dark gauge boson masses are 10 TeV and 16 TeV, respectively. When only the dark gauge boson facilitates dark matter annihilations, we find an upper bound of 3 TeV and 6 TeV for the dark matter and dark gauge boson, respectively. Overall, using the gauge portal as a template, we describe a method to not only place upper bounds on the dark matter mass but also on the new particles with Standard Model quantum numbers. We briefly discuss the reach of future accelerator, direct and indirect detection experiments for this class of models.

  1. Developing patient portals in a fragmented healthcare system.

    Science.gov (United States)

    Otte-Trojel, Terese; de Bont, Antoinette; Aspria, Marcello; Adams, Samantha; Rundall, Thomas G; van de Klundert, Joris; de Mul, Marleen

    2015-10-01

    Use of patient portals may contribute to improved patient health and experiences and better organizational performance. In the Netherlands, patient portals have gained considerable attention in recent years, as evidenced by various policy initiatives and practical efforts directed at developing portals. Due to the fragmented setup of the Dutch healthcare system patient portals that give patients access to information and services from across their providers are developed in inter-organizational collaboration. The objective of this paper is to identify and describe the types of collaborations, or networks, that have been established to develop patient portals in the Netherlands. Understanding the characteristics of these networks as well as the development of their respective portals enables us to assess the enabling and constraining effects of different network types on patient portal initiatives. We used qualitative methods including interview and documents analysis. In a first step, we interviewed eighteen experts and reviewed relevant national policy and strategy documents. Based on this orientation, we selected three networks we deemed to be representative of inter-organizational efforts to develop Dutch patient portals in 2012. In a second step, we interviewed twelve representatives of these patient portal networks and collected documents related to the portals. We applied content analytic techniques to analyze data from the three cases. The three studied networks differed in their number and diversity of actors, the degree to which these actors were mutually dependent, the degree to which network governance was decentralized, and the dynamics of the network structures. We observed that the portals developed in networks displaying the highest degree of these characteristics experienced most difficulties associated with developing patient portals - such as achieving interoperability, successful implementation, regulatory complaisance, and financial

  2. The ADRICOSM STAR GeoPortal

    Science.gov (United States)

    Giorgetti, Alessandra; Cesarini, Claudia; Gambetta, Marco; Reseghetti, Franco; Vinci, Matteo

    2010-05-01

    From Stockholm (1972) to Rio de Janeiro (1992) and to Johannesburg (2002), environmental protection objectives are related to the principles of sustainable development. This includes the following important components: participation, information, communication, training (capacity building) and education. Better information ensure more participation from individuals, and allows citizens to take part in many different actions that can influence the policy process. Participation to political decisions need access to reliable and quality controlled information. The ADRICOSM Portal was developed in order to manage data diversity, provide access to any kind of product, provide metadata completeness and accuracy. The product, as defined in ADRICOSM, is anything that can be offered to a client and that might satisfy a want or need. This implied the implementation of services that was taking into consideration the diversity of the objects to be provided to users: observations, model outputs, maps, etc. The implementation of the portal was based on two metadata levels: 1. Directory level - consisting of broad descriptions of the contents of data sets; used to locate data sets of potential interest and 2. Data level - consisting of the actual data objects. The portal was developed as a simplified front end for the partners data management systems, giving emphasis on federated access points focused on thematic aspects. This was based on the idea that specialized customer-related access points can be better carried out by delegated teams of experts who know the needs of different customers, define the user software which is most suited to them. The data management systems provide facilities for two data tracks, one in real-time (or near-realtime) and one in delayed mode. Both tracks are based on the same data sources and transmission systems, but the data follow different routes and are processed differently depending on user requirements. The real-time data and model products

  3. The SmartGeo Portal: A retrospective

    Science.gov (United States)

    Heilmann, Zeno; Satta, Guido; Bonomi, Ernesto

    2016-04-01

    The SmartGeo portal was created in a follow-up project that evolved from the geophysical data imaging services of a Grid computing portal for Geoscience, called GRIDA3. The scope of the project was to support commercial geotechnical service providers as well as academic researchers working in near-surface geoscience. Starting from the existing services, the SmartGeo portal was set up on new hardware, using the latest version of the grid portal environment EnginFrame. After a first working version was established, the services were reviewed, updated and accompanied by new services according to the feedback we received from our partners. One partner for instance experienced large difficulties in a project that aimed at delineating the aquifer for finding water pollutant substances in an industrial area of Basel. The seismic imaging service inherited from the previous portal was employing a data-driven algorithm optimized to provide, directly during data acquisition, nearly in real-time a first image of the subsurface structure. Different to this, our user needed for his data from a geologically very complex and noisy urban environment the maximum lateral resolution and noise reduction possible. For this purpose we added two cutting edge data imaging algorithms able to deliver such high precision results by simultaneously optimizing, for every single image point, all parameters of the mathematical model---a procedure which increased the computational effort by one or two magnitudes, respectively. Thus, parallel computing on grid infrastructure served for maximizing the image resolution instead for generating real-time results. This proved also very useful for the data of an academic partner, recorded for imaging the structure of a shallow sedimentary basin, where we could obtain strongly improved seismic velocity information using these new algorithms. A general user request was to implement interactive data visualization tools. To fulfill this demand we took

  4. Advances in the management of childhood portal hypertension.

    Science.gov (United States)

    McKiernan, Patrick; Abdel-Hady, Mona

    2015-05-01

    Portal hypertension is one of the most serious complications of childhood liver disease, and variceal bleeding is the most feared complication. Most portal hypertension results from cirrhosis but extra hepatic portal vein obstruction is the single commonest cause. Upper gastrointestinal endoscopy endoscopy remains necessary to diagnose gastro-esophageal varices. Families of children with portal hypertension should be provided with written instructions in case of gastrointestinal bleeding. Children with large varices should be considered for primary prophylaxis on a case-by-case basis. The preferred method is variceal band ligation. Children with acute bleeding should be admitted to hospital and treated with antibiotics and pharmacotherapy before urgent therapeutic endoscopy. All children who have bled should then receive secondary prophylaxis. The preferred method is variceal band ligation and as yet there is little evidence to support the use of β-blockers. Children with extrahepatic portal vein obstruction should be assessed for suitability of mesoportal bypass.

  5. Advances in the treatment of portal hypertension in cirrhosis.

    Science.gov (United States)

    Kimer, N; Wiese, S; Mo, S; Møller, S; Bendtsen, F

    2016-08-01

    Non-selective beta-blockers and handling of esophageal varices has been key elements in the treatment of portal hypertension in recent decades. Liver vein catheterization has been essential in diagnosis and monitoring of portal hypertension, but ongoing needs for noninvasive tools has led to research in areas of both biomarkers, and transient elastography, which displays promising results in discerning clinically significant portal hypertension. Novel research into the areas of hepatic stellate cell function and the dynamic components of portal hypertension has revealed promising areas of treatment modalities, targeting intestinal decontamination, angiogenesis, inflammation and oxidative stress. Future studies may reveal if these initiatives lead to developments of new drugs for treatment of portal hypertension.

  6. Advances in the treatment of portal hypertension in cirrhosis

    DEFF Research Database (Denmark)

    Kimer, Nina; Wiese, S; Mo, S S

    2016-01-01

    Non-selective beta-blockers and handling of esophageal varices has been key elements in the treatment of portal hypertension in recent decades. Liver vein catheterization has been essential in diagnosis and monitoring of portal hypertension, but ongoing needs for noninvasive tools has led...... to research in areas of both biomarkers, and transient elastography, which displays promising results in discerning clinically significant portal hypertension. Novel research into the areas of hepatic stellate cell function and the dynamic components of portal hypertension has revealed promising areas...... of treatment modalities, targeting intestinal decontamination, angiogenesis, inflammation and oxidative stress. Future studies may reveal if these initiatives lead to developments of new drugs for treatment of portal hypertension....

  7. A Web portal for CMS Grid job submission and management

    Energy Technology Data Exchange (ETDEWEB)

    Braun, David [Department of Physics, Purdue University, W. Lafayette, IN 47907 (United States); Neumeister, Norbert, E-mail: neumeist@purdue.ed [Rosen Center for Advanced Computing, Purdue University, W. Lafayette, IN 47907 (United States)

    2010-04-01

    We present a Web portal for CMS Grid submission and management. The portal is built using a JBoss application server. It has a three tier architecture; presentation, business logic and data. Bean based business logic interacts with the underlying Grid infrastructure and pre-existing external applications, while the presentation layer uses AJAX to offer an intuitive, functional interface to the back-end. Application data aggregating information from the portal as well as the external applications is persisted to the server memory cache and then to a backend database. We describe how the portal exploits standard, off-the-shelf commodity software together with existing Grid infrastructures in order to facilitate job submission and monitoring for the CMS collaboration. This paper describes the design, development, current functionality and plans for future enhancements of the portal.

  8. Interface methods for using intranet portal organizational memory information system.

    Science.gov (United States)

    Ji, Yong Gu; Salvendy, Gavriel

    2004-12-01

    In this paper, an intranet portal is considered as an information infrastructure (organizational memory information system, OMIS) supporting organizational learning. The properties and the hierarchical structure of information and knowledge in an intranet portal OMIS was identified as a problem for navigation tools of an intranet portal interface. The problem relates to navigation and retrieval functions of intranet portal OMIS and is expected to adversely affect user performance, satisfaction, and usefulness. To solve the problem, a conceptual model for navigation tools of an intranet portal interface was proposed and an experiment using a crossover design was conducted with 10 participants. In the experiment, a separate access method (tabbed tree tool) was compared to an unified access method (single tree tool). The results indicate that each information/knowledge repository for which a user has a different structural knowledge should be handled separately with a separate access to increase user satisfaction and the usefulness of the OMIS and to improve user performance in navigation.

  9. A Web portal for CMS Grid job submission and management

    International Nuclear Information System (INIS)

    Braun, David; Neumeister, Norbert

    2010-01-01

    We present a Web portal for CMS Grid submission and management. The portal is built using a JBoss application server. It has a three tier architecture; presentation, business logic and data. Bean based business logic interacts with the underlying Grid infrastructure and pre-existing external applications, while the presentation layer uses AJAX to offer an intuitive, functional interface to the back-end. Application data aggregating information from the portal as well as the external applications is persisted to the server memory cache and then to a backend database. We describe how the portal exploits standard, off-the-shelf commodity software together with existing Grid infrastructures in order to facilitate job submission and monitoring for the CMS collaboration. This paper describes the design, development, current functionality and plans for future enhancements of the portal.

  10. Stent Recanalization of Chronic Portal Vein Occlusion in a Child

    International Nuclear Information System (INIS)

    Cwikiel, Wojciech; Solvig, Jan; Schroder, Henrik

    2000-01-01

    An 8-year-old boy with a 21/2 year history of portal hypertension and repeated bleedings from esophageal varices, was referred for treatment. The 3.5-cm-long occlusion of the portal vein was passed and the channel created was stabilized with a balloon-expandable stent; a portosystemic stent-shunt was also created. The portosystemic shunt closed spontaneously within 1 month, while the recanalized segment of the portal vein remained open. The pressure gradient between the intrahepatic and extrahepatic portal vein branches dropped from 17 mmHg to 0 mmHg. The pressure in the portal vein dropped from 30 mmHg to 17 mmHg and the bleedings stopped. The next dilation of the stent was performed 12 months later due to an increased pressure gradient; the gastroesophageal varices disappeared completely. Further dilation of the stent was planned after 2, 4, and 6 years

  11. Development of integrated containment and surveillance system for fast critical facility FCA. Portal and penetration monitors

    International Nuclear Information System (INIS)

    Mukaiyama, Takehiko; Ogawa, Hironobu; Yokota, Yasuhiro.

    1998-01-01

    Manpower and radiation exposure problems, accompanied by frequent Non Destructive Assay (NDA) based inspections at the Fast Critical Facility FCA of Japan Atomic Energy Research Institute (JAERI), are a burden for both the inspectorates and the facility operator. In the hope of alleviating these burdens, the development of containment and surveillance measures for the FCA was initiated in 1979. The integrated containment and surveillance system consists of a portal monitor and a penetration monitor. The reactor building provides an ideal containment measure because of its explosion-proof, airtight structure and limited number of penetrations. The function of the portal monitor is to detect undeclared removal of nuclear material from the reactor building through the doorway. The penetration monitor is designed for surveillance of diversion routes through containment boundaries, and of safeguards related activities for bypassing the portal monitor. The combination of monitoring by the penetration monitor of containment boundaries and all their penetrations except for the doorway, and monitoring by the portal monitor, provides complete coverage of realistic diversion routes. The development of the system was completed in 1988 and the field trial test was conducted for the period of twelve running months. The final report on the field trial was concluded on January 1990. The major conclusion of the report was that the system is effective, reliable and efficient. Following this successful conclusion, the International Atomic Energy Agency (IAEA) accepted the system for meeting its safeguards goals at the FCA on condition that an independent IAEA authentication equipment is provided. The development of the authentication equipment is accomplished as an separate Japan Support Programme for Agency Safeguards (JASPAS) task. (author)

  12. Dosimetric characterization of an electronic portal imaging device (EPID) and development of a portal dosimetry simple model; Caracterizacion dosimetrica de un dispositivo electronico de imagen portal (EPID) y desarrollo de un modelo simple de dosimetria portal

    Energy Technology Data Exchange (ETDEWEB)

    Ripol ValentIn, O.; GarcIa Romero, A.; Hernandez Vitoria, A.; Jimenez Albericio, J.; Cortes Rodicio, J.; Millan Cebrian, E.; Ruiz Manzano, P.; Canellas Anoz, M.

    2010-07-01

    The use of the Electronic Portal Imaging Devices (EPID) for the quality control of linear accelerators of electrons is increasingly extended in practice. In this work the dosimetric characteristics of an EPID OptiVue{sup TM}1000 ST were studied and a friendly and simple method for the absorbed dose calibration was suggested. This method is based on a simple mathematical model, including: an absorbed dose transformation coefficient and image lag and field shape corrections. Software tools were developed in order to process the information and the results were validated by comparing them with the measured data with ionization chambers. The studied device showed suitable characteristics for its use for EPID dosimetry and the calculated results fitted satisfactorily with the dose planes obtained with the ionization chambers. Keeping in mind the model limitations, we concluded that it is possible to start the use of the EPID for the accelerator quality control and improvements for the current model should be studied, as well as other suitable applications: e.g. the Intensity Modulated Radiation Therapy (IMRT) treatment verification procedures. (Author).

  13. Automatic verification of step-and-shoot IMRT field segments using portal imaging

    International Nuclear Information System (INIS)

    Woo, M.K.; Lightstone, A.W.; Shan, G.; Kumaraswamy, L.; Li, Y.

    2003-01-01

    In step-and-shoot IMRT, many individual beam segments are delivered. These segments are generated by the IMRT treatment planning system and subsequently transmitted electronically through computer hardware and software modules before they are finally delivered. Hence, an independent system that monitors the actual field shape during treatment delivery is an added level of quality assurance in this complicated process. In this paper we describe the development and testing of such a system. The system verifies the field shape by comparing the radiation field detected by the built-in portal imaging system on the linac to the actual field shape planned on the treatment planning system. The comparison is based on a software algorithm that detects the leaf edge positions of the radiation field on the portal image and compares that to the calculated positions. The process is fully automated and requires minimal intervention of the radiation therapists. The system has been tested with actual clinical plan sequences and was able to alert the operator of incorrect settings in real time

  14. Fast image acquisition and processing on a TV camera-based portal imaging system

    International Nuclear Information System (INIS)

    Baier, K.; Meyer, J.

    2005-01-01

    The present paper describes the fast acquisition and processing of portal images directly from a TV camera-based portal imaging device (Siemens Beamview Plus trademark). This approach employs not only hard- and software included in the standard package installed by the manufacturer (in particular the frame grabber card and the Matrox(tm) Intellicam interpreter software), but also a software tool developed in-house for further processing and analysis of the images. The technical details are presented, including the source code for the Matrox trademark interpreter script that enables the image capturing process. With this method it is possible to obtain raw images directly from the frame grabber card at an acquisition rate of 15 images per second. The original configuration by the manufacturer allows the acquisition of only a few images over the course of a treatment session. The approach has a wide range of applications, such as quality assurance (QA) of the radiation beam, real-time imaging, real-time verification of intensity-modulated radiation therapy (IMRT) fields, and generation of movies of the radiation field (fluoroscopy mode). (orig.)

  15. Splanchnic-aortic inflammatory axis in experimental portal hypertension

    Science.gov (United States)

    Aller, Maria-Angeles; de las Heras, Natalia; Nava, Maria-Paz; Regadera, Javier; Arias, Jaime; Lahera, Vicente

    2013-01-01

    Splanchnic and systemic low-grade inflammation has been proposed to be a consequence of long-term prehepatic portal hypertension. This experimental model causes minimal alternations in the liver, thus making a more selective study possible for the pathological changes characteristic of prehepatic portal hypertension. Low-grade splanchnic inflammation after long-term triple partial portal vein ligation could be associated with liver steatosis and portal hypertensive intestinal vasculopathy. In fact, we have previously shown that prehepatic portal hypertension in the rat induces liver steatosis and changes in lipid and carbohydrate metabolism similar to those produced in chronic inflammatory conditions described in metabolic syndrome in humans. Dysbiosis and bacterial translocation in this experimental model suggest the existence of a portal hypertensive intestinal microbiome implicated in both the splanchnic and systemic alterations related to prehepatic portal hypertension. Among the systemic impairments, aortopathy characterized by oxidative stress, increased levels of proinflammatory cytokines and profibrogenic mediators stand out. In this experimental model of long-term triple portal vein ligated-rats, the abdominal aortic proinflammatory response could be attributed to oxidative stress. Thus, the increased aortic reduced-nicotinamide-adenine dinucleotide phosphate [NAD(P)H] oxidase activity could be associated with reactive oxygen species production and promote aortic inflammation. Also, oxidative stress mediated by NAD(P)H oxidase has been associated with risk factors for inflammation and atherosclerosis. The splanchnic and systemic pathology that is produced in the long term after triple partial portal vein ligation in the rat reinforces the validity of this experimental model to study the chronic low-grade inflammatory response induced by prehepatic portal hypertension. PMID:24307792

  16. Altered blood-brain barrier permeability in rats with prehepatic portal hypertension turns to normal when portal pressure is lowered

    Science.gov (United States)

    Eizayaga, Francisco; Scorticati, Camila; Prestifilippo, Juan P; Romay, Salvador; Fernandez, Maria A; Castro, José L; Lemberg, Abraham; Perazzo, Juan C

    2006-01-01

    AIM: To study the blood-brain barrier integrity in prehepatic portal hypertensive rats induced by partial portal vein ligation, at 14 and 40 d after ligation when portal pressure is spontaneously normalized. METHODS: Adult male Wistar rats were divided into four groups: Group I: Sham14d , sham operated; Group II: PH14d , portal vein stenosis; (both groups were used 14 days after surgery); Group III: Sham40d, Sham operated and Group IV: PH40d Portal vein stenosis (Groups II and IV used 40 d after surgery). Plasma ammonia, plasma and cerebrospinal fluid protein and liver enzymes concentrations were determined. Trypan and Evans blue dyes, systemically injected, were investigated in hippocampus to study blood-brain barrier integrity. Portal pressure was periodically recorded. RESULTS: Forty days after stricture, portal pressure was normalized, plasma ammonia was moderately high, and both dyes were absent in central nervous system parenchyma. All other parameters were reestablished. When portal pressure was normalized and ammonia level was lowered, but not normal, the altered integrity of blood-brain barrier becomes reestablished. CONCLUSION: The impairment of blood-brain barrier and subsequent normalization could be a mechanism involved in hepatic encephalopathy reversibility. Hemodynamic changes and ammonia could trigger blood-brain barrier alterations and its reestablishment. PMID:16552803

  17. Combined Rex-bypass shunt with pericardial devascularization alleviated prehepatic portal hypertension caused by cavernomatous transformation of portal vein.

    Science.gov (United States)

    Wang, Ruo-Yi; Wang, Jun-Feng; Liu, Qian; Ma, Nan; Chen, Wei-Xiu; Li, Jin-Liang

    2017-09-01

    To evaluate the effects of combined Rex-bypass shunt and pericardial devascularization on prehepatic portal hypertension secondary to cavernomatous transformation of portal vein (CTPV). Forty-two patients aged from 3 years to 49 years (divided into 3 groups), 26 cases male and 16 female, with prehepatic vascular hepertention were treated with Rex-bypass shunt combined with pericardial devascularization. In each patient, preoperative assessment included ultrasound and computed tomographic angiography of the portal vein and blood analysis. The procedure was Rex-bypass shunt (with or without graft), and patients with moderate or severe gastroesophageal varices required additional paraesophagogastric devascularization. Splenectomy or subtotal splenectomy was performed if combined hypersplenism co-existed. All data were analyzed retrospectively. No intraoperative death occurred, blood routine analysis improved (P portal vein (LPV) significantly increased, the esophageal and gastric varices significantly relieved in 34 patients (P portal hypertension caused by CTPV.

  18. Quantitative study of the hemodynamic changes of portal vein in hepatocellular carcinoma with arterioportal shunts

    International Nuclear Information System (INIS)

    Shen Xinying; Shan Hong

    2005-01-01

    Objective: To measure the changes of portal venous pressure before and after APS by percutaneous portal vein catheterization and to quantitatively analyse the correlation between portal pressure and portal hypertension. Methods: All the 18 central arterioportal shunts (APS) patients with hepatocellular carcinoma (HCC) were treated with embolization of APS and TACE, and the pressure of portal vein was measured by percutaneous portal vein catheterization pre- and post-embolization of APS. Color doppler sonography and endoscopy were employed to investigate before and 2 weeks after embolization in all patients. Results: The pressure of portal vein decreased significantly after embolization, and the decreased rate was 5.4%-33.3% with the mean rate 20.1%. After the embolization, the width of portal vein decreased and the blood flow velocity of portal vein increased significantly, P<0.01. Hepatofugal portal venous flow was seen in 13 patients before embolization, and restored to hepatopetal flow in 7 patients after embolization. In the 10 patients with more than 20% decrease in portal venous pressure, the portal hypertension improved markedly; while in other 8 patients with less than 20 percent decrease in portal venous pressure, the clinical symptoms of portal hypertension did not improve as much. Conclusions: Embolization of APS can decrease portal venous pressure, with the mean decreasing rate over 20%. Decreasing by 20% or more of portal venous pressure can improve effectively the portal hypertension symptoms including ascites, variceal bleeding, and diarrhea. (authors)

  19. MR image-guided portal verification for brain treatment field

    International Nuclear Information System (INIS)

    Yin Fangfang; Gao Qinghuai; Xie Huchen; Nelson, Diana F.; Yu Yan; Kwok, W. Edmund; Totterman, Saara; Schell, Michael C.; Rubin, Philip

    1998-01-01

    Purpose: To investigate a method for the generation of digitally reconstructed radiographs directly from MR images (DRR-MRI) to guide a computerized portal verification procedure. Methods and Materials: Several major steps were developed to perform an MR image-guided portal verification procedure. Initially, a wavelet-based multiresolution adaptive thresholding method was used to segment the skin slice-by-slice in MR brain axial images. Some selected anatomical structures, such as target volume and critical organs, were then manually identified and were reassigned to relatively higher intensities. Interslice information was interpolated with a directional method to achieve comparable display resolution in three dimensions. Next, a ray-tracing method was used to generate a DRR-MRI image at the planned treatment position, and the ray tracing was simply performed on summation of voxels along the ray. The skin and its relative positions were also projected to the DRR-MRI and were used to guide the search of similar features in the portal image. A Canny edge detector was used to enhance the brain contour in both portal and simulation images. The skin in the brain portal image was then extracted using a knowledge-based searching technique. Finally, a Chamfer matching technique was used to correlate features between DRR-MRI and portal image. Results: The MR image-guided portal verification method was evaluated using a brain phantom case and a clinical patient case. Both DRR-CT and DRR-MRI were generated using CT and MR phantom images with the same beam orientation and then compared. The matching result indicated that the maximum deviation of internal structures was less than 1 mm. The segmented results for brain MR slice images indicated that a wavelet-based image segmentation technique provided a reasonable estimation for the brain skin. For the clinical patient case with a given portal field, the MR image-guided verification method provided an excellent match between

  20. NASA Sea Level Change Portal - It not just another portal site

    Science.gov (United States)

    Huang, T.; Quach, N.; Abercrombie, S. P.; Boening, C.; Brennan, H. P.; Gill, K. M.; Greguska, F. R., III; Jackson, R.; Larour, E. Y.; Shaftel, H.; Tenenbaum, L. F.; Zlotnicki, V.; Moore, B.; Moore, J.; Boeck, A.

    2017-12-01

    The NASA Sea Level Change Portal (https://sealevel.nasa.gov) is designed as a "one-stop" source for current sea level change information, including interactive tools for accessing and viewing regional data, a virtual dashboard of sea level indicators, and ongoing updates through a suite of editorial products that include content articles, graphics, videos, and animations. With increasing global temperatures warming the ocean and melting ice sheets and glaciers, there is an immediate need both for accelerating sea level change research and for making this research accessible to scientists in disparate discipline, to the general public, to policy makers and business. The immersive and innovative NASA portal debuted at the 2015 AGU attracts thousands of daily visitors and over 30K followers on Facebook®. Behind its intuitive interface is an extensible architecture that integrates site contents, data for various sources, visualization, horizontal-scale geospatial data analytic technology (called NEXUS), and an interactive 3D simulation platform (called the Virtual Earth System Laboratory). We will present an overview of our NASA portal and some of our architectural decisions along with discussion on our open-source, cloud-based data analytic technology that enables on-the-fly analysis of heterogeneous data.

  1. ACCOUNTING INFORMATION INTEGRATION TROUGH AN ENTERPRISE PORTAL

    Directory of Open Access Journals (Sweden)

    Gianina RIZESCU

    2014-06-01

    Full Text Available If companies are lacking integrated enterprise software applications, or they simply do not use them on a large scale, accounting departments have to face lots of difficulties, concerning both the inflexibility in achieving good results and the limited possibility of communicating these results. Thus, most times, accounting departments are limited to generating predefined reports provided by a software application and the most they can do is export these reports into Microsoft Excel. Another cause which leads to late obtaining and publishing of accounting information is the lack of data from other departments and their corresponding software applications. That is why, in many enterprises, accounting data becomes irrelevant for the users. The main goal of this article is to show how accounting can benefit from an integrated software solution, namely an enterprise portal.

  2. The BAOBAB data portal and DACCIWA database

    Science.gov (United States)

    Brissebrat, Guillaume; Belmahfoud, Nizar; Cloché, Sophie; Ferré, Hélène; Fleury, Laurence; Mière, Arnaud; Ramage, Karim

    2017-04-01

    In the framework of the African Monsoon Multidisciplinary Analyses (AMMA) programme, several tools have been developed in order to boost the data and information exchange between researchers from different disciplines: a user-friendly data management and dissemination system, quasi real-time display websites and a scientific paper exchange collaborative tool. The information system is enriched by past and ongoing projects (IMPETUS, FENNEC, ESCAPE, QweCI, ACASIS, DACCIWA...) addressing meteorology, atmospheric chemistry, hydrology, extreme events, health, adaptation of human societies... It is becoming a reference information system on environmental issues in West Africa: BAOBAB (Base Afrique de l'Ouest beyond AMMA Base). The projects include airborne, ground-based and ocean measurements, social science surveys, satellite data use, modelling studies and value-added product development. Therefore, the BAOBAB data portal enables to access a great amount and a large variety of data: - 250 local observation datasets, that have been collected by operational networks since 1850, long term monitoring research networks and intensive scientific campaigns; - 1350 outputs of a socio-economics questionnaire; - 60 operational satellite products and several research products; - 10 output sets of meteorological and ocean operational models and 15 of research simulations. Data documentation complies with metadata international standards, and data are delivered into standard formats. The data request interface takes full advantage of the database relational structure and enables users to elaborate multicriteria requests (period, area, property…). The BAOBAB data portal counts about 900 registered users, and 50 data requests every month. The databases and data portal have been developed and are operated jointly by SEDOO and ESPRI in France: http://baoab.sedoo.fr. The ongoing DACCIWA (Dynamics-Aerosol-Chemistry-Cloud Interactions over West Africa) project uses the BAOBAB portal to

  3. Superheavy dark matter through Higgs portal operators

    Science.gov (United States)

    Kolb, Edward W.; Long, Andrew J.

    2017-11-01

    The WIMPzilla hypothesis is that the dark matter is a super-weakly-interacting and superheavy particle. Conventionally, the WIMPzilla abundance is set by gravitational particle production during or at the end of inflation. In this study we allow the WIMPzilla to interact directly with Standard Model fields through the Higgs portal, and we calculate the thermal production (freeze-in) of WIMPzilla dark matter from the annihilation of Higgs boson pairs in the plasma. The two particle-physics model parameters are the WIMPzilla mass and the Higgs-WIMPzilla coupling. The two cosmological parameters are the reheating temperature and the expansion rate of the universe at the end of inflation. We delineate the regions of parameter space where either gravitational or thermal production is dominant, and within those regions we identify the parameters that predict the observed dark matter relic abundance. Allowing for thermal production opens up the parameter space, even for Planck-suppressed Higgs-WIMPzilla interactions.

  4. Impact of hepatitis C oral therapy in portal hypertension.

    Science.gov (United States)

    Libânio, Diogo; Marinho, Rui Tato

    2017-07-14

    Chronic hepatitis C is a leading cause of morbidity and mortality, mainly related to fibrosis/cirrhosis and portal hypertension. Direct antiviral agents are highly effective and safe and can now cure > 90% of the patients. Sustained viral response (SVR) after interferon-based regimens has been associated with improvement in liver function, fibrosis and portal hypertension in a significant proportion of patients, although a point of no return seems to exist from which viral elimination is no longer capable of preventing portal hypertension progression and liver decompensation. Indeed, although SVR is associated with improvement of hepatic venous pressure gradients and therefore a decreased risk of de novo esophageal varices, several studies show that viral clearance does not eliminate the risk of variceal progression, liver decompensation and death in patients with pre-established portal hypertension. Although evidence about the effects of direct antiviral agents (DAAs) on clinically significant outcomes is still scarce and with short follow-up, DAAs can decrease the burden of the disease if patients are timely treated before significant fibrosis and portal hypertension develops. Studies with longer follow-up are waited to establish the real magnitude of hepatitis C treatment on portal hypertension. Future studies should also focus on predictors of portal hypertension resolution since it can influence management and avoid unnecessary monitoring.

  5. Endothelial dysfunction in the regulation of portal hypertension

    Science.gov (United States)

    Iwakiri, Yasuko

    2013-01-01

    Portal hypertension is caused by an increased intrahepatic resistance, a major consequence of cirrhosis. Endothelial dysfunction in liver sinusoidal endothelial cells (LSECs) decreases the production of vasodilators, such as nitric oxide (NO) and favors vasoconstriction. This contributes to an increased vascular resistance in the intrahepatic/sinusoidal microcirculation. Portal hypertension, once developed, causes endothelial cell (EC) dysfunction in the extrahepatic, i.e. splanchnic and systemic, circulation. Unlike LSEC dysfunction, EC dysfunction in the splanchnic and systemic circulation overproduces vasodilator molecules, leading to arterial vasodilatation. In addition, portal hypertension leads to the formation of portosystemic collateral vessels. Both arterial vasodilatation and portosystemic collateral vessel formation exacerbate portal hypertension by increasing the blood flow through the portal vein. Pathologic consequences, such as esophageal varices and ascites, result. While the sequence of pathological vascular events in cirrhosis and portal hypertension have been elucidated, the underlying cellular and molecular mechanisms causing EC dysfunctions are not yet fully understood. This review article summarizes the current cellular and molecular studies on EC dysfunctions found during the development of cirrhosis and portal hypertension with a focus on intra- and extrahepatic circulation. The article ends by discussing future directions of study for EC dysfunctions. PMID:21745318

  6. Clinical role of non-invasive assessment of portal hypertension.

    Science.gov (United States)

    Bolognesi, Massimo; Di Pascoli, Marco; Sacerdoti, David

    2017-01-07

    Measurement of portal pressure is pivotal in the evaluation of patients with liver cirrhosis. The measurement of the hepatic venous pressure gradient represents the reference method by which portal pressure is estimated. However, it is an invasive procedure that requires significant hospital resources, including experienced staff, and is associated with considerable cost. Non-invasive methods that can be reliably used to estimate the presence and the degree of portal hypertension are urgently needed in clinical practice. Biochemical and morphological parameters have been proposed for this purpose, but have shown disappointing results overall. Splanchnic Doppler ultrasonography and the analysis of microbubble contrast agent kinetics with contrast-enhanced ultrasonography have shown better accuracy for the evaluation of patients with portal hypertension. A key advancement in the non-invasive evaluation of portal hypertension has been the introduction in clinical practice of methods able to measure stiffness in the liver, as well as stiffness/congestion in the spleen. According to the data published to date, it appears to be possible to rule out clinically significant portal hypertension in patients with cirrhosis ( i.e ., hepatic venous pressure gradient ≥ 10 mmHg) with a level of clinically-acceptable accuracy by combining measurements of liver stiffness and spleen stiffness along with Doppler ultrasound evaluation. It is probable that the combination of these methods may also allow for the identification of patients with the most serious degree of portal hypertension, and ongoing research is helping to ensure progress in this field.

  7. Transcatheter arterial chemoembolization of hepatocellular carcinoma with portal vein invasion

    International Nuclear Information System (INIS)

    Lee, Young Rahn; Lee, Ki Yeol; Cho, Seong Beom; Cha, In Ho; Chung, Kyoo Byung

    1993-01-01

    Transcatheter arterial chemoembolization(TACE) is an imperative method for the management of inoperable hepatocellular carcinoma(HCC). It is well known that primary HCC frequently invades the portal venous system and forms a tumor thrombus obstructing the portal blood flow which makes unfavorable prognosis of patient. We retrospectively reviewed 58 patients who reviewed TACE(minimum 3 times) of HCC invading into portal venous system. Group 1(n=29) which showed peripheral portal vein invasion had better clinical and laboratory response. Group 2(n=17) which showed first order portal branch invasion had similar response to Group 3(n=12), which had main portal invasion. Group 1 showed no difference in survival time between TAC and TACE, but, in Group 2 and 3, embolization with chemotherapy made longer survival than chemotherapy only. Clinical level of AFP was meaningful in Group 1 and 2 as decreasing value. Our results provides that careful selection of TAE and case by case Coil/Gelfoam embolization can improve the mean survival and clinical response when HCC evidently invades portal venous system

  8. Portal monitoring for detecting fissile materials and chemical explosives

    International Nuclear Information System (INIS)

    Albright, D.

    1992-01-01

    The portal monitoring of pedestrians, packages, equipment, and vehicles entering or leaving areas of high physical security has been common for many years. Many nuclear facilities rely on portal monitoring to prevent the theft or diversion of plutonium and highly enriched uranium. At commercial airports, portals are used to prevent firearms and explosives from being smuggled onto airplanes. An August 1989 Federal Aviation Administration (FAA) regulation requires US airlines to screen luggage on international flights for chemical explosives. This paper reports that portal monitoring is now being introduced into arms-control agreements. Because some of the portal-monitoring equipment that would be useful in verifying arms-control agreements is already widely used as part of the physical security systems at nuclear facilities and commercial airports, the authors review these uses of portal monitoring, as well as its role in verifying the INF treaty. Then the authors survey the major types of portal-monitoring equipment that would be most useful in detecting nuclear warheads or fissile material

  9. [Portal perfusion with right gastroepiploic vein flow in liver transplant].

    Science.gov (United States)

    Mendoza-Sánchez, Federico; Javier-Haro, Francisco; Mendoza-Medina, Diego Federico; González-Ojeda, Alejandro; Cortés-Lares, José Antonio; Fuentes-Orozco, Clotilde

    Liver transplantation in patients with liver cirrhosis, portal vein thrombosis, and cavernous transformation of the portal vein, is a complex procedure with high possibility of liver graft dysfunction. It is performed in 2-19% of all liver transplants, and has a significantly high mortality rate in the post-operative period. Other procedures to maintain portal perfusion have been described, however there are no reports of liver graft perfusion using right gastroepiploic vein. A 20 year-old female diagnosed with cryptogenic cirrhosis, with a Child-Pugh score of 7 points (class "B"), and MELD score of 14 points, with thrombosis and cavernous transformation of the portal vein, severe portal hypertension, splenomegaly, a history of upper gastrointestinal bleeding due to oesophageal varices, and left renal agenesis. The preoperative evaluation for liver transplantation was completed, and the right gastroepiploic vein of 1-cm diameter was observed draining to the infrahepatic inferior vena cava and right suprarenal vein. An orthotopic liver transplantation was performed from a non-living donor (deceased on January 30, 2005) using the Piggy-Back technique. Portal vein perfusion was maintained using the right gastroepiploic vein, and the outcome was satisfactory. The patient was discharged 13 days after surgery. Liver transplantation was performed satisfactorily, obtaining an acceptable outcome. In this case, the portal perfusion had adequate blood flow through the right gastroepiploic vein. Copyright © 2015 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  10. Development of Geospatial Map Based Election Portal

    Science.gov (United States)

    Gupta, A. Kumar Chandra; Kumar, P.; Vasanth Kumar, N.

    2014-11-01

    The Geospatial Delhi Limited (GSDL), a Govt. of NCT of Delhi Company formed in order to provide the geospatial information of National Capital Territory of Delhi (NCTD) to the Government of National Capital Territory of Delhi (GNCTD) and its organs such as DDA, MCD, DJB, State Election Department, DMRC etc., for the benefit of all citizens of Government of National Capital Territory of Delhi (GNCTD). This paper describes the development of Geospatial Map based Election portal (GMEP) of NCT of Delhi. The portal has been developed as a map based spatial decision support system (SDSS) for pertain to planning and management of Department of Chief Electoral Officer, and as an election related information searching tools (Polling Station, Assembly and parliamentary constituency etc.,) for the citizens of NCTD. The GMEP is based on Client-Server architecture model. It has been developed using ArcGIS Server 10.0 with J2EE front-end on Microsoft Windows environment. The GMEP is scalable to enterprise SDSS with enterprise Geo Database & Virtual Private Network (VPN) connectivity. Spatial data to GMEP includes delimited precinct area boundaries of Voters Area of Polling stations, Assembly Constituency, Parliamentary Constituency, Election District, Landmark locations of Polling Stations & basic amenities (Police Stations, Hospitals, Schools and Fire Stations etc.). GMEP could help achieve not only the desired transparency and easiness in planning process but also facilitates through efficient & effective tools for management of elections. It enables a faster response to the changing ground realities in the development planning, owing to its in-built scientific approach and open-ended design.

  11. Tsunami.gov: NOAA's Tsunami Information Portal

    Science.gov (United States)

    Shiro, B.; Carrick, J.; Hellman, S. B.; Bernard, M.; Dildine, W. P.

    2014-12-01

    We present the new Tsunami.gov website, which delivers a single authoritative source of tsunami information for the public and emergency management communities. The site efficiently merges information from NOAA's Tsunami Warning Centers (TWC's) by way of a comprehensive XML feed called Tsunami Event XML (TEX). The resulting unified view allows users to quickly see the latest tsunami alert status in geographic context without having to understand complex TWC areas of responsibility. The new site provides for the creation of a wide range of products beyond the traditional ASCII-based tsunami messages. The publication of modern formats such as Common Alerting Protocol (CAP) can drive geographically aware emergency alert systems like FEMA's Integrated Public Alert and Warning System (IPAWS). Supported are other popular information delivery systems, including email, text messaging, and social media updates. The Tsunami.gov portal allows NOAA staff to easily edit content and provides the facility for users to customize their viewing experience. In addition to access by the public, emergency managers and government officials may be offered the capability to log into the portal for special access rights to decision-making and administrative resources relevant to their respective tsunami warning systems. The site follows modern HTML5 responsive design practices for optimized use on mobile as well as non-mobile platforms. It meets all federal security and accessibility standards. Moving forward, we hope to expand Tsunami.gov to encompass tsunami-related content currently offered on separate websites, including the NOAA Tsunami Website, National Tsunami Hazard Mitigation Program, NOAA Center for Tsunami Research, National Geophysical Data Center's Tsunami Database, and National Data Buoy Center's DART Program. This project is part of the larger Tsunami Information Technology Modernization Project, which is consolidating the software architectures of NOAA's existing TWC's into

  12. Corporate portal system at PAKS NPP, Hungary

    International Nuclear Information System (INIS)

    2009-01-01

    The new Corporate Portal System (CPS) of Paks NPP was launched in November 2006. The portal is based on one of the latest technologies, Plumtree Enterprise WEB 5.0. The main purpose of the installation of the new technology was to serve the working culture change, to give a platform to access all information and applications including the integrated process model used at the NPP. The new technology also supports those goals which were defined in the organization development programme: e.g. to improve internal communication with the establishment of communities of practice. Installation of the CPS has provided a powerful tool for knowledge management; it is possible to share and find all information through a controlled access in documents from various sources, to have links to people, portlets and different communities. Document management of the Paks NPP is supported by the integration of the Document 5 application, as the new Electronic Data Management System (EDMS) and the CPS. Depending on their access rights, all users of the CPS, through Microsoft Internet Explorer, can access technical, economic and human resources documents which are stored anywhere on the internal network (file servers, EDMS, old INRANET). The CPS is also accessible from the internet through a secure connection. The main concept is the integration of all applications to one platform and to help users to find all information they need. An access control list specifies which users and groups have access to an object (and what kind of access privileges they have such as read, select, edit, admin)

  13. Surgery for portal hypertension in children: A 12-year review.

    Science.gov (United States)

    Patel, N; Grieve, A; Hiddema, J; Botha, J; Loveland, J

    2017-11-06

    Portal hypertension is a common and potentially devastating condition in children. Notwithstanding advances in the nonsurgical management of portal hypertension, surgery remains an important treatment modality in select patients. We report here on our experience in the past 12 years. To describe the profile of, indication for, and complications of shunt surgery in children with portal hypertension. Twelve children underwent shunt surgery between 2005 and 2017. Patient records were reviewed. Fourteen procedures were performed on 12 patients during the study period. The median age at surgery was 6.5 (range 1 - 18) years. Six patients were male. Gastrointestinal bleeding that was not amenable to endoscopic control was the most common indication for surgery. Portal vein thrombosis was the most common cause of portal hypertension in our series (n=11). Two-thirds (8/12) of all patients had an identifiable underlying risk factor for portal vein thrombosis. One-third of all patients (4/12) underwent a meso-portal bypass procedure (Rex shunt), while 58% (7/12) were managed with a distal splenorenal shunt. All patients received postoperative thromboprophylaxis. We experienced a single mortality, 1 patient experienced shunt thrombosis that required revision shunt surgery, and 2 patients experienced anastomotic strictures, with one being managed with revision surgery and the other currently awaiting radiological venoplasty. Surgery is a safe and important tool in the management of children with non-cirrhotic portal hypertension and those with sufficient hepatic reserve who fail to respond to more conservative methods for the treatment of side effects of portal hypertension.

  14. Some thoughts to realignment of PortalU

    International Nuclear Information System (INIS)

    Konstantinidis, Stefanie; Kruse, Fred

    2013-01-01

    Environmental information is the basis for improving the environmental situation in the EU. The challenge poses the tailoring of information to a defined group of interest and not only the technical possibility to retrieve the environmental information. Even though, the technical infrastructure for retrieving public environmental information is the first step. Hence, the clear understanding of the needs of the general public is essential for a successful environmental information portal for the interest group ''general public''. What does this mean referring to the German Environmental Information Portal PortalU? Since the launch of PortalU the focus of the portal is set on making available official environmental information especially on German Federal Republic and Federal States level. Currently, information from web pages represents the greatest amount of information. In contrast, information from environmental data catalogs and further data bases represent a smaller amount of information within PortalU. But quantity itself does not tell anything about the demand of a target group. The experience of the last years has shown that environmental interested citizens use mainly general search engines like Google to find information from public environmental web pages. Thus it would be worth thinking about a realignment of PortalU. The idea of a prospective alignment of PortalU is to concentrate on important environmental information, which is not easily found via Google and other general search engines. This information is mainly provided via environmental data catalogs and possibly further data bases. Some thoughts about the potential form and design of a respectively aligned environmental portal are discussed in the paper. (orig.)

  15. Some thoughts to realignment of PortalU

    Energy Technology Data Exchange (ETDEWEB)

    Konstantinidis, Stefanie; Kruse, Fred [Lower Saxony Ministry of Environment and Climate Protection, Hannover (Germany). Coordination Centre PortalU

    2013-07-01

    Environmental information is the basis for improving the environmental situation in the EU. The challenge poses the tailoring of information to a defined group of interest and not only the technical possibility to retrieve the environmental information. Even though, the technical infrastructure for retrieving public environmental information is the first step. Hence, the clear understanding of the needs of the general public is essential for a successful environmental information portal for the interest group ''general public''. What does this mean referring to the German Environmental Information Portal PortalU? Since the launch of PortalU the focus of the portal is set on making available official environmental information especially on German Federal Republic and Federal States level. Currently, information from web pages represents the greatest amount of information. In contrast, information from environmental data catalogs and further data bases represent a smaller amount of information within PortalU. But quantity itself does not tell anything about the demand of a target group. The experience of the last years has shown that environmental interested citizens use mainly general search engines like Google to find information from public environmental web pages. Thus it would be worth thinking about a realignment of PortalU. The idea of a prospective alignment of PortalU is to concentrate on important environmental information, which is not easily found via Google and other general search engines. This information is mainly provided via environmental data catalogs and possibly further data bases. Some thoughts about the potential form and design of a respectively aligned environmental portal are discussed in the paper. (orig.)

  16. Development of Educational SharePoint portal for coding students

    OpenAIRE

    Colomer Castelló, Gerard

    2016-01-01

    The project will explain what is SharePoint, why is used and who does use it. It will also expose some alternatives, compare them to SharePoint and expose the pros and cons. The main objective of this project will be developing an educational SharePoint portal. Using this portal, coding students will be able to share their solutions to different exercises, vote the best solutions and comment them. This portal will be developed using only software and servers obtained legally without any cost....

  17. Using Patient Portals to Increase Engagement in Patients with Cancer.

    Science.gov (United States)

    Rodriguez, Elizabeth S

    2018-04-03

    To review patient portals which serve as a tool for patient engagement by increasing access to electronic health care information and expanding ways to communicate with health care providers. Reviews of the literature and first-hand experience. Meaningful Use requirements propelled the design and development of patient portals in recent years. Patient engagement in oncology can improve quality of life and outcomes. Oncology nurses facilitate patient adoption of patient portals and support usage. Patient education helps manage communication expectations and understanding of online medical information. Copyright © 2018 Elsevier Inc. All rights reserved.

  18. OntoWeaver S: supporting the design of knowledge portals

    OpenAIRE

    Lei, Yuangui; Motta, Enrico; Domingue, John

    2004-01-01

    This paper presents OntoWeaver-S, an ontology-based infrastructure for building knowledge portals. In particular, OntoWeaver-S is integrated with a comprehensive web service platform, IRS-II, for the publication, discovery, and execution of web services. In this way, OntoWeaver-S supports the access and provision of remote web services for knowledge portals. Moreover, it provides a set of comprehensive site ontologies to model and represent knowledge portals, and thus is able to offer high le...

  19. Per-rectal portal scintigraphy in chronic liver diseases

    International Nuclear Information System (INIS)

    Frusciante, V.; Barbano, F.; Btuno, M.; Facciorusso, D.; Tonti, P.; Giacobbe, A.; Andriulli, A.; Vettori, P.G.P.

    1993-01-01

    Portal circulation has been evaluated by per-rectal portal scintigraphy in 21 controls and in 30 pts affected by chronic liver diseases. Tc99m-pertechnetate (10 mci) was given through a Nelaton's catheter in the upper rectum; a per-rectal portal shunt index (SI) was calculated. A relevant overlap is evident between controls and CHP pts; no overlap exists between controls and B or C graded cirrhosis. We conclude that the technique may be suggested to monitor the course of chronic liver diseases and different therapeutic regimens. (orig.) [de

  20. Radiation pager

    International Nuclear Information System (INIS)

    Warren, J.L.; Vadnais, K.G.

    1998-01-01

    Methods of interdicting nuclear materials to date have favored the use of large portal detectors at choke points, or hand carried instruments used by trained personnel for conducting spot searches. Although these methods are effective in some instances, it is often impractical to insert choke points at busy traffic areas, and it is not cost effective to maintain a force of skilled operators whose focus is nuclear interdiction. Recent technology developments are causing profound changes in the philosophy and methods employed for interdicting nuclear materials. Breakthrough advances in the miniaturization of detectors and low power electronics have made possible a new class of small gamma-ray radiation detectors, roughly the size of a message pager, with unprecedented sensitivity for their size. These instruments, named Radiation Pagers TM , are ideally suited for use by untrained individual law enforcement personnel and emergency responders in the course of their regular duties. New tactics that utilize a radiation detector worn by every officer are creating a moving curtain of detection with a significantly higher likelihood of locating illicit nuclear contraband. These individual detectors also provide each officer with a high level of confidence that they are not being unknowingly irradiated in the course of their work. (author)

  1. Mouse and Rat Models of Induction of Hepatic Fibrosis and Assessment of Portal Hypertension.

    Science.gov (United States)

    Klein, Sabine; Schierwagen, Robert; Uschner, Frank Erhard; Trebicka, Jonel

    2017-01-01

    Portal hypertension either develops due to progressive liver fibrosis or is the consequence of vascular liver diseases such as portal vein thrombosis or non-cirrhotic portal hypertension. This chapter focuses on different rodent models of liver fibrosis with portal hypertension and also in few non-cirrhotic portal hypertension models. Importantly, after the development of portal hypertension, the proper assessment of drug effects in the portal and systemic circulation should be discussed. The last part of the chapter is dedicated in these techniques to assess the in vivo hemodynamics and the ex vivo techniques of the isolated liver perfusion and vascular contractility.

  2. Portal hypertension: a review of portosystemic collateral pathways and endovascular interventions

    International Nuclear Information System (INIS)

    Pillai, A.K.; Andring, B.; Patel, A.; Trimmer, C.; Kalva, S.P.

    2015-01-01

    The portal vein is formed at the confluence of the splenic and superior mesenteric vein behind the head of the pancreas. Normal blood pressure within the portal system varies between 5 and 10 mmHg. Portal hypertension is defined when the gradient between the portal and systemic venous blood pressure exceeds 5 mmHg. The most common cause of portal hypertension is cirrhosis. In cirrhosis, portal hypertension develops due to extensive fibrosis within the liver parenchyma causing increased vascular resistance. In addition, the inability of the liver to metabolise certain vasodilators leads to hyperdynamic splanchnic circulation resulting in increased portal blood flow. Decompression of the portal pressure is achieved by formation of portosystemic collaterals. In this review, we will discuss the pathophysiology, anatomy, and imaging findings of spontaneous portosystemic collaterals and clinical manifestations of portal hypertension with emphasis on the role of interventional radiology in the management of complications related to portal hypertension

  3. Analysis of interfraction and intrafraction variation during tangential breast irradiation with an electronic portal imaging device

    International Nuclear Information System (INIS)

    Smith, Ryan P.; Bloch, Peter; Harris, Eleanor E.; McDonough, James; Sarkar, Abhirup; Kassaee, Alireza; Avery, Steven; Solin, Lawrence J.

    2005-01-01

    Purpose: To evaluate the daily setup variation and the anatomic movement of the heart and lungs during breast irradiation with tangential photon beams, as measured with an electronic portal imaging device. Methods and materials: Analysis of 1,709 portal images determined changes in the radiation field during a treatment course in 8 patients. Values obtained for every image included central lung distance (CLD) and area of lung and heart within the irradiated field. The data from these measurements were used to evaluate variation from setup between treatment days and motion due to respiration and/or patient movement during treatment delivery. Results: The effect of respiratory motion and movement during treatment was minimal: the maximum range in CLD for any patient on any day was 0.25 cm. The variation caused by day-to-day setup variation was greater, with CLD values for patients ranging from 0.59 cm to 2.94 cm. Similar findings were found for heart and lung areas. Conclusions: There is very little change in CLD and corresponding lung and heart area during individual radiation treatment fractions in breast tangential fields, compared with a relatively greater amount of variation that occurs between days

  4. Imaging of the ventricular septal wall and the portal vein by digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Kyoichi; Harashima, Haruhiko; Yamada, Hiromi; Hiraishi, Takahisa; Mikami, Fumio [National Medical Center of Hospital, Tokyo (Japan)

    1983-06-01

    Digital subtraction angiography (DSA) was performed in 2 cases of hypertrophic cardiomyopathy and 2 cases of portal vein disorder. In hypertrophic cardiomyopathy, DSA with the infusion of isopaque 370 at the speed of 5 to 7 ml/sec produced the image of the ventricular septal wall, showing a small ejection fraction. Of portal vein disorders, DSA revealed the portal vein and was helpful in diagnosing tumoral thrombosis of the portal vein in a case of liver carcinoma and portal hypertension.

  5. Pulmonary hypertension associated with non-cirrhotic portal hypertension in systemic lupus erythematosus.

    OpenAIRE

    Woolf, D.; Voigt, M. D.; Jaskiewicz, K.; Kalla, A. A.

    1994-01-01

    A case of non-cirrhotic portal hypertension in a patient with systemic lupus erythematosus, the first of our knowledge, is described. Severe pulmonary hypertension was associated with the portal hypertension and with markers of active auto-immunity. Pulmonary hypertension has not previously been associated with non-cirrhotic portal hypertension. The coexistence of vasculopathy of the portal and pulmonary vascular beds in this patient with active autoimmunity supports the postulate that portal...

  6. Software engineering knowledge at your fingertips: Experiences with a software engineering-portal

    OpenAIRE

    Punter, T.; Kalmar, R.

    2003-01-01

    In order to keep up the pace with technology development, knowledge on Software Engineering (SE) methods, techniques, and tools is required. For an effective and efficient knowledge transfer, especially Small and Medium-sized Enterprises (SMEs) might benefit from Software Engineering Portals (SE-Portals). This paper provides an analysis of SE-Portals by distinguishing two types: 1) the Knowledge Portal and 2) the Knowledge & Community Portal. On behalf of the analysis we conclude that most SE...

  7. The 2013 general elections in Malaysia: An analysis of online news portals

    OpenAIRE

    Kasim, Azahar; Mohd Sani, Mohd Azizuddin

    2016-01-01

    This research analyzed the coverage of online news portals during the election campaign in Malaysia's 13th General Election on 5th May 2013. There were two types of news portals chosen for this research: 1) the mainstream online news portals, namely The Star Online, Berita Harian Online, Bernama Online and Utusan Online; and 2) the alternative news portals consisting of political parties' publications: the Harakah Daily, Roketkini and Keadilan Daily; and the independent news portals of The Ma...

  8. Ontology-based Metadata Portal for Unified Semantics

    Data.gov (United States)

    National Aeronautics and Space Administration — The Ontology-based Metadata Portal for Unified Semantics (OlyMPUS) will extend the prototype Ontology-Driven Interactive Search Environment for Earth Sciences...

  9. Development of the public transport research compendium portal

    CSIR Research Space (South Africa)

    Dimitrov, L

    2009-07-01

    Full Text Available research and development programme. The research compendium portal is a database providing access to information pertaining to public transport projects in the Republic of South Africa from 2003. The specific projects include regulatory, policy...

  10. Radionuclide and ultrasonic investigations in liver cirrhosis with portal hypertension

    International Nuclear Information System (INIS)

    Khodzhibekov, M.Kh.; Rikhsieva, L.Eh.; Nazyrov, F.G.

    1988-01-01

    Combined radionuclide and ultrasonic investigations (UNI) were performed in 95 patients with liver cirrhosis complicated by portal hypertension. Liver and splenic shape structure and the presence of fluid in the abdominal cavity were assessed in USI. Radionuclide methods of investigation of the hepatic blood flow, assessment of the shape, size and structure of RP distribution in the liver and spleen, and for calculation of the hepatosplenic index. The most significant signs of differentiation of stages of portal hypertension were the presence and amount of fluid in the abdominal cavity and a hepatic blood flow value reflecting the gravity of portal hypertension. Combined radionuclide and ultrasonic investigations permitted a differentiated approach to staging of portal hypertension and assessment of liver and splenic morphofunctional state that could play an important role in the choice of tactics of surgery of liver cirrhosis

  11. Radionuclide and ultrasonic investigations in liver cirrhosis with portal hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Khodzhibekov, M Kh; Rikhsieva, L Eh; Nazyrov, F G

    1988-08-01

    Combined radionuclide and ultrasonic investigations (UNI) were performed in 95 patients with liver cirrhosis complicated by portal hypertension. Liver and splenic shape structure and the presence of fluid in the abdominal cavity were assessed in USI. Radionuclide methods of investigation of the hepatic blood flow, assessment of the shape, size and structure of RP distribution in the liver and spleen, and for calculation of the hepatosplenic index. The most significant signs of differentiation of stages of portal hypertension were the presence and amount of fluid in the abdominal cavity and a hepatic blood flow value reflecting the gravity of portal hypertension. Combined radionuclide and ultrasonic investigations permitted a differentiated approach to staging of portal hypertension and assessment of liver and splenic morphofunctional state that could play an important role in the choice of tactics of surgery of liver cirrhosis.

  12. Contemporary use of elastography in liver fibrosis and portal hypertension

    DEFF Research Database (Denmark)

    Thiele, Maja; Kjærgaard, Maria; Thielsen, Peter

    2017-01-01

    significant portal hypertension, techniques and limitations. Four types of ultrasound elastography exist, but there is scarce evidence comparing the different techniques. The majority of experience concern transient elastography for diagnosing fibrosis and cirrhosis in patients with chronic viral hepatitis C...

  13. Case studies in geographic information systems for internet portals

    Science.gov (United States)

    2012-06-30

    The following report investigates the experiences of transportation agencies in the deployment of Internet-based mapping portals based on GIS. It presents background information, a series of case studies, and a summary of conclusions given the experi...

  14. Outsourcing the Portal: Another Branch in the Decision Tree.

    Science.gov (United States)

    McMahon, Tim

    2000-01-01

    Discussion of the management of information resources in organizations focuses on the use of portal technologies to update intranet capabilities. Considers application outsourcing decisions, reviews benefits (including reducing costs) as well as concerns, and describes application service providers (ASPs). (LRW)

  15. The Portals 4.1 Network Programming Interface

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, Brian; Brightwell, Ronald B.; Grant, Ryan; Hemmert, Karl Scott; Pedretti, Kevin; Wheeler, Kyle; Underwood, Keith D; Riesen, Rolf; Maccabe, Arthur B.; Hudson, Trammel

    2017-04-01

    This report presents a specification for the Portals 4 networ k programming interface. Portals 4 is intended to allow scalable, high-performance network communication betwee n nodes of a parallel computing system. Portals 4 is well suited to massively parallel processing and embedded syste ms. Portals 4 represents an adaption of the data movement layer developed for massively parallel processing platfor ms, such as the 4500-node Intel TeraFLOPS machine. Sandia's Cplant cluster project motivated the development of Version 3.0, which was later extended to Version 3.3 as part of the Cray Red Storm machine and XT line. Version 4 is tar geted to the next generation of machines employing advanced network interface architectures that support enh anced offload capabilities.

  16. Popular Tasks in the ForeSee Portal

    Science.gov (United States)

    Access the robust American Customer Satisfaction Index Portal to obtain information, such as search terms used by survey respondents, satisfaction by audience type, and responses to specific survey questions; and learn how to use various filters.

  17. Integrating Space Communication Network Capabilities via Web Portal Technologies

    Science.gov (United States)

    Johnston, Mark D.; Lee, Carlyn-Ann; Lau, Chi-Wung; Cheung, Kar-Ming; Levesque, Michael; Carruth, Butch; Coffman, Adam; Wallace, Mike

    2014-01-01

    We have developed a service portal prototype as part of an investigation into the feasibility of using Java portlet technology as a means of providing integrated access to NASA communications network services. Portal servers provide an attractive platform for this role due to the various built-in collaboration applications they can provide, combined with the possibility to develop custom inter-operating portlets to extent their functionality while preserving common presentation and behavior. This paper describes various options for integration of network services related to planning and scheduling, and results based on use of a popular open-source portal framework. Plans are underway to develop an operational SCaN Service Portal, building on the experiences reported here.

  18. A Rare Case Report of Spontaneous Resolution of Hepatic Portal ...

    African Journals Online (AJOL)

    Hepatic portal venous gas (HPVG) was first described ... suppurative cholangitis, peptic ulcer disease, volvulus and fecal impaction.[1-4] The prognosis is related to the underlying pathology and the coexistence of a chronic medical disease,.

  19. Knowledge portal: a tool to capture university requirements

    Science.gov (United States)

    Mansourvar, Marjan; Binti Mohd Yasin, Norizan

    2011-10-01

    New technologies, especially, the Internet have made a huge impact on knowledge management and information dissemination in education. The web portal as a knowledge management system is very popular topics in many organizations including universities. Generally, a web portal defines as a gateway to online network accessible resources through the intranet, extranet or Internet. This study develops a knowledge portal for the students in the Faculty of Computer Science and Information Technology (FCSIT), University of Malaya (UM). The goals of this portal are to provide information for the students to help them to choose the right courses and major that are relevant to their intended future jobs or career in IT. A quantitative approach used as the selected method for this research. Quantitative method provides an easy and useful way to collect data from a large sample population.

  20. USAID Business/Partner to Government Transaction Portal

    Data.gov (United States)

    US Agency for International Development — This project expands on the FY12 external facing portal implementation and leverages the Identity Management solution framework to provide greater efficiency for...

  1. Global Mercury Observatory System Land-based Monitoring Data Portal

    Data.gov (United States)

    U.S. Environmental Protection Agency — Global Mercury Observation System On-line Data Portal. This dataset is associated with the following publication: Carbone, F., A. Bruno, A. Naccarato, F. De Simone,...

  2. Interventional radiology in the management of portal hypertension

    International Nuclear Information System (INIS)

    Punamiya, Sundeep J

    2008-01-01

    From being a mere (though important) diagnostic tool, radiology has evolved to become an integral part of therapy in portal hypertension today. Various procedures are currently available, the choice depending on the etiology and location of disease, the pathoanatomy, and the symptomatology. The main aim of any procedure is to reduce the portal pressure by either direct or indirect methods. This can be achieved with transjugular intrahepatic portosystemic shunt (TIPS), recanalization of the hepatic vein outflow, recanalization of the portal vein and its tributaries, recanalization of dysfunctional portosystemic shunts, partial splenic embolization, and embolization of arterioportal shunts. When any of these procedures cannot be performed due to anatomical or physiological reasons, the symptoms can often be controlled effectively with embolization of varices or balloon-occluded retrograde transvenous obliteration of varices (BRTO). This article briefly describes the procedures, their results, and their current status in the treatment of portal hypertension

  3. Imaging and Radiological Interventions of Portal Vein Thrombosis

    Energy Technology Data Exchange (ETDEWEB)

    Hidajat, N.; Stobbe, H.; Griesshaber, V.; Felix, R.; Schroder, R.J. [Academic Teaching Hospital of the Univ. of Hannover (Germany). Central Dept. of Diagnostic and Interventional Radiology, Hospital Peine

    2005-07-01

    Portal vein thrombosis (PVT) is diagnosed by imaging methods. Once diagnosed by means of ultrasound, Doppler ultrasound can be performed to distinguish between a benign and malignant thrombus. If further information is required, magnetic resonance angiography or contrast-enhanced computed tomography is the next step, and if these tests are unsatisfactory, digital subtraction angiography should be performed. Many papers have been published dealing with alternative methods of treating PVT, but the material is fairly heterogeneous. In symptomatic non-cavernomatous PVT, recanalization using local methods is recommended by many authors. Implantation of transjugular intrahepatic portosystemic shunt is helpful in cirrhotic patients with non-cavernomatous PVT in reducing portal pressure and in diminishing the risk of re-thrombosis. In non-cirrhotic patients with recent PVT, some authors recommend anticoagulation alone. In chronic thrombotic occlusion of the portal vein, local measures may be implemented if refractory symptoms of portal hypertension are evident.

  4. Tumoural portal vein thrombosis. Enhancement with MnDPDP

    International Nuclear Information System (INIS)

    Marti-Bonmati, L.; Lonjedo, E.; Mathieu, D.; Coffin, C.; Poyatos, C.; Anglade, M.C.

    1997-01-01

    Purpose: Intrahepatic thrombus is usually associated with either cirrhosis or hepatocellular carcinoma (HCC). Most HCCs enhance after the administration of MnDPDP (Teslascan). Our objective was to analyze the enhancement characteristics of tumour portal vein thrombi. Material and Methods: Thrombi affecting the main or segmental portal veins (17 cases) and the suprahepatic inferior vena cava (1 case) were retrospectively selected from a series of 128 patients studied with MR imaging before and after the administration of MnDPDP. Enhancement was assessed qualitatively and quantitatively. Results: All tumour thrombi enhanced after MnDPDP administration. The enhancement was more conspicuous in the GRE images. On the quantitative evaluation, the portal thrombus enhancement was greater for GRE images than SE images. Portal thrombi enhanced more than the liver and the HCCs. There was a significant difference between the enhancement of the HCCs and the thrombi with both MR imaging techniques. (orig./AJ)

  5. Advances in diagnosis and treatment of portal hypertensive biliopathy

    Directory of Open Access Journals (Sweden)

    WENG Ningna

    2014-08-01

    Full Text Available With the progress in research on portal hypertension in recent years, portal hypertensive biliopathy (PHB has attracted more and more attention. The pathophysiology and clinical manifestations of PHB, as well as the main methods for the diagnosis and treatment of this disease, are briefly described. The pathogenesis of PHB remains unclear, and it has been postulated that the external pressure of portal cavernoma and the ischemic stricture of the bile duct may play a role. Magnetic resonance cholangiopancreatography is the primary diagnostic tool for PHB. Currently, it is thought that asymptomatic PHB patients do not require any treatment, and symptomatic PHB patients should receive individualized treatment, which mainly included reducing portal pressure and relieving biliary obstruction. Transjugular intrahepatic portosystemic shunt has become the first-line therapy for symptomatic PHB. More research and practice are needed for further understanding of PHB.

  6. A Standardization Framework for Electronic Government Service Portals

    Science.gov (United States)

    Sarantis, Demetrios; Tsiakaliaris, Christos; Lampathaki, Fenareti; Charalabidis, Yannis

    Although most eGovernment interoperability frameworks (eGIFs) cover adequately the technical aspects of developing and supporting the provision of electronic services to citizens and businesses, they do not exclusively address several important areas regarding the organization, presentation, accessibility and security of the content and the electronic services offered through government portals. This chapter extends the scope of existing eGIFs presenting the overall architecture and the basic concepts of the Greek standardization framework for electronic government service portals which, for the first time in Europe, is part of a country's eGovernment framework. The proposed standardization framework includes standards, guidelines and recommendations regarding the design, development and operation of government portals that support the provision of administrative information and services to citizens and businesses. By applying the guidelines of the framework, the design, development and operation of portals in central, regional and municipal government can be systematically addressed resulting in an applicable, sustainable and ever-expanding framework.

  7. The Portals 4.0 network programming interface.

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, Brian W.; Brightwell, Ronald Brian; Pedretti, Kevin; Wheeler, Kyle Bruce; Hemmert, Karl Scott; Riesen, Rolf E.; Underwood, Keith Douglas; Maccabe, Arthur Bernard; Hudson, Trammell B.

    2012-11-01

    This report presents a specification for the Portals 4.0 network programming interface. Portals 4.0 is intended to allow scalable, high-performance network communication between nodes of a parallel computing system. Portals 4.0 is well suited to massively parallel processing and embedded systems. Portals 4.0 represents an adaption of the data movement layer developed for massively parallel processing platforms, such as the 4500-node Intel TeraFLOPS machine. Sandias Cplant cluster project motivated the development of Version 3.0, which was later extended to Version 3.3 as part of the Cray Red Storm machine and XT line. Version 4.0 is targeted to the next generation of machines employing advanced network interface architectures that support enhanced offload capabilities.

  8. The portals 4.0.1 network programming interface.

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, Brian W.; Brightwell, Ronald Brian; Pedretti, Kevin; Wheeler, Kyle Bruce; Hemmert, Karl Scott; Riesen, Rolf E.; Underwood, Keith Douglas; Maccabe, Arthur Bernard; Hudson, Trammell B.

    2013-04-01

    This report presents a specification for the Portals 4.0 network programming interface. Portals 4.0 is intended to allow scalable, high-performance network communication between nodes of a parallel computing system. Portals 4.0 is well suited to massively parallel processing and embedded systems. Portals 4.0 represents an adaption of the data movement layer developed for massively parallel processing platforms, such as the 4500-node Intel TeraFLOPS machine. Sandias Cplant cluster project motivated the development of Version 3.0, which was later extended to Version 3.3 as part of the Cray Red Storm machine and XT line. Version 4.0 is targeted to the next generation of machines employing advanced network interface architectures that support enhanced offload capabilities. 3

  9. The Mandela Portal – past, present and future

    African Journals Online (AJOL)

    mpho ngoepe

    its development, as well as providing insight into a benchmarking exercise that ... Figure 2: Diagram showing the Mandela Portal as it was in September 2004 .... the NMF, the Presidential Libraries are federally funded and, therefore, had a ...

  10. Classification of hypervascular liver lesions based on hepatic artery and portal vein blood supply coefficients calculated from triphasic CT scans.

    Science.gov (United States)

    Boas, F Edward; Kamaya, Aya; Do, Bao; Desser, Terry S; Beaulieu, Christopher F; Vasanawala, Shreyas S; Hwang, Gloria L; Sze, Daniel Y

    2015-04-01

    Perfusion CT of the liver typically involves scanning the liver at least 20 times, resulting in a large radiation dose. We developed and validated a simplified model of tumor blood supply that can be applied to standard triphasic scans and evaluated whether this can be used to distinguish benign and malignant liver lesions. Triphasic CTs of 46 malignant and 32 benign liver lesions were analyzed. For each phase, regions of interest were drawn in the arterially enhancing portion of each lesion, as well as the background liver, aorta, and portal vein. Hepatic artery and portal vein blood supply coefficients for each lesion were then calculated by expressing the enhancement curve of the lesion as a linear combination of the enhancement curves of the aorta and portal vein. Hepatocellular carcinoma (HCC) and hypervascular metastases, on average, both had increased hepatic artery coefficients compared to the background liver. Compared to HCC, benign lesions, on average, had either a greater hepatic artery coefficient (hemangioma) or a greater portal vein coefficient (focal nodular hyperplasia or transient hepatic attenuation difference). Hypervascularity with washout is a key diagnostic criterion for HCC, but it had a sensitivity of 72 % and specificity of 81 % for diagnosing malignancy in our diverse set of liver lesions. The sensitivity for malignancy was increased to 89 % by including enhancing lesions that were hypodense on all phases. The specificity for malignancy was increased to 97 % (p = 0.039) by also examining hepatic artery and portal vein blood supply coefficients, while maintaining a sensitivity of 76 %.

  11. Use of 99mTCO4(-) trans-splenic portal scintigraphy for diagnosis of portosystemic shunts in 28 dogs.

    Science.gov (United States)

    Morandi, Federica; Cole, Robert C; Tobias, Karen M; Berry, Clifford R; Avenell, James; Daniel, Gregory B

    2005-01-01

    Ultrasound-guided percutaneous trans-splenic portal scintigraphy (TSPS) using 99mTcO4(-) has been used to image the portal venous system in normal dogs. Compared with per-rectal portal scintigraphy, it provides higher count density, consistent nuclear venograms of the splenic and portal vein, and significantly decreased radiation exposures. This paper describes the use of TSPS for the diagnosis of portosystemic shunts in 28 dogs. TSPS was performed injecting 70 +/- 28 MBq of 99mTcO4(-) (mean +/- SD) into the splenic parenchyma with ultrasound guidance. A dynamic acquisition at a frame rate of four frames/s for 5 min was initiated after placement of the needle and approximately 2s prior to injection. All dogs had diagnoses confirmed via exploratory laparotomy or ultrasonographic identification of the shunting vessel(s). Three studies (10.7%) were nondiagnostic because of intraperitoneal rather than intrasplenic injection of the radionuclide. Three pathways were recognized on the scintigraphic images: (1) portoazygos shunts--the 99mTcO4(-) bolus traveled dorsally, running parallel to the spine and entering the heart craniodorsally; (2) single portocaval or splenocaval shunts--the 99mTcO4(-) bolus ran from the area of the portal vein/splenic vein junction in a linear fashion toward the caudal vena cava entering the heart caudally; (3) internal thoracic shunt-the 99mTcO4 bolus traveled ventrally along the thorax and abdomen entering the cranial aspect of the heart. Single and multiple shunts were easily distinguished. There were no distinguishing features between single intra and extrahepatic portocaval shunts.

  12. Assessment of private hospital portals: A conceptual model

    Directory of Open Access Journals (Sweden)

    Mehdi Alipour-Hafezi

    2016-01-01

    Full Text Available Introduction: Hospital portals, as the first virtual entry, play an important role in connecting people with hospital and also presenting hospital virtual services. The main purpose of this article was to suggest a conceptual model to improve Tehran private hospital portals. The suggested model can be used by all the health portals that are in the same circumstances and all the health portals which are in progress. Method: This is a practical research, using evaluative survey research method. Research population includes all the private hospital portals in Tehran, 34 portals, and ten top international hospital portals. Data gathering tool used in this research was a researcher-made checklist including 14 criteria and 77 sub-criteria with their weight score. In fact, objective observation with the mentioned checklist was used to gather information. Descriptive statistics were used to analyze the data and tables and graphs were used to present the organized data. Also, data were analyzed using independent t-test. Conceptual modeling technique was used to design the model and demonstration method was used to evaluate the proposed model. In this regard, SPSS statistical software was used to perform the tests. Results:The comparative study between the two groups of portals, TPH and WTH, in the 14 main criteria showed that the value of t-test in contact information criteria was 0.862, portal page specification was -1.378, page design criteria -1.527, updating pages -0.322, general information and access roads -3.161, public services -7.302, patient services -4.154, patient data -8.703, research and education -9.155, public relationship -3.009, page technical specifications -4.726, telemedicine -7.488, pharmaceutical services -6.183, and financial services -2.782. Finally, the findings demonstrated that Tehran private hospital portals in criterion of contact information were favorable; page design criteria were relatively favorable; page technical

  13. A strategic analysis of Business Objects' portal application

    OpenAIRE

    Kristinsson, Olafur Oskar

    2007-01-01

    Business Objects is the leading software firm producing business intelligence software. Business intelligence is a growing market. Small to medium businesses are increasingly looking at business intelligence. Business Objects' flagship product in the enterprise market is Business Objects XI and for medium-size companies it has Crystal Decisions. Portals are the front end for the two products. InfoView, Business Objects portal application, lacks a long-term strategy. This analysis evaluates...

  14. Ultra Sound Evaluation of Choledochal Cyst With Portal Hypertension

    Directory of Open Access Journals (Sweden)

    Alam P

    2016-05-01

    Full Text Available Choledochal cyst is an uncommon congenital cystic dilatation of the bile duct. The underlying etiology is believed to be an anomalous junction of the pancreatic duct and common bile duct (CBD that allows free reflux of pancreatic enzymes into the CBD, weakening its wall. Portal hypertension is a rare complication of choledochal cyst. We report a case of choledochal cyst with portal hypertension confirmed by surgery

  15. THE ROLE OF ENTERPRISE PORTALS IN ENTERPRISE INTEGRATION

    Directory of Open Access Journals (Sweden)

    Gianina RIZESCU

    2006-01-01

    Full Text Available Today’s enterprises are moving business systems to the Internet - to connect people, business processes, and people to business processes in enterprise and across enterprise boundaries. The portal brings it all together: business processes, departmental sites, knowledge management resources, enterprise management systems, CRM systems, analytics, email, calendars, external content, transactions,administration, workflow, and more. The goal of this paper is to present the role of the Enterprise Portal in internal and external enterprise integration.

  16. Protection of estrogen in portal hypertension gastropathy: an experimental model

    Directory of Open Access Journals (Sweden)

    Maria Isabel Morgan-Martins

    2011-09-01

    Full Text Available CONTEXT: Portal hypertension is a complication secondary to cirrhosis that is characterized by increased blood flow and/or vascular resistance in the portal system, causing the appearance of a hyperdynamic collateral circulation. Partial portal vein ligation is an experimental model used in rats to study the pathophysiological mechanisms involved in pre-hepatic portal hypertension. Estrogen E2 is an antioxidant molecule with various physiological actions. OBJECTIVES: To evaluate the antioxidant activity of endogenous estrogen in an experimental model of partial portal vein ligation by comparing intact with castrated rats. METHODS: Twenty Wistar rats, weighing on average 250 g were used and divided into four groups: sham-operated (SO; intact (I with partial portal vein ligation (I + PPVL, castrated (C and castrated with partial ligation of the vein (C + PPVL. Day 1: castration or sham-operation; day 7, PPVL surgery; on day 15 post-PPVL, portal pressure in the mesenteric vein of rats was measured on polygraph Letica. Lipid peroxidation in the stomach was assessed using the technique of thiobarbituric acid reactive substances and activity of antioxidant enzymes superoxide dismutase, catalase and glutathione peroxidase. Statistical analysis was done with ANOVA - Student-Newman-Keuls (mean ± SE, and P<0.05 was considered as significant. RESULTS: Portal pressure was significantly increased in C + PPVL as compared to the other groups. There was no significant difference in the group of intact rats. TBARS showed significant damage in C and C + PPVL in relation to others. Antioxidant enzymes were significantly increased in the castrated rats with subsequent PPVL as compared to the other groups. CONCLUSION: We suggest that estrogen E2 plays a protective role in intact compared with castrated rats because it presents hydrophenolic radicals in its molecule, thus acting as an antioxidant in this experimental model.

  17. Protection of estrogen in portal hypertension gastropathy: an experimental model.

    Science.gov (United States)

    Morgan-Martins, Maria Isabel; Jacques, Simone Iahnig; Hartmann, Renata Minuzzo; Marques, Camila Moraes; Marroni, Cláudio Augusto; Marroni, Norma Possa

    2011-01-01

    Portal hypertension is a complication secondary to cirrhosis that is characterized by increased blood flow and/or vascular resistance in the portal system, causing the appearance of a hyperdynamic collateral circulation. Partial portal vein ligation is an experimental model used in rats to study the pathophysiological mechanisms involved in pre-hepatic portal hypertension. Estrogen E2 is an antioxidant molecule with various physiological actions. To evaluate the antioxidant activity of endogenous estrogen in an experimental model of partial portal vein ligation by comparing intact with castrated rats. Twenty Wistar rats, weighing on average 250 g were used and divided into four groups: sham-operated (SO); intact (I) with partial portal vein ligation (I + PPVL), castrated (C) and castrated with partial ligation of the vein (C + PPVL). Day 1: castration or sham-operation; day 7, PPVL surgery; on day 15 post-PPVL, portal pressure in the mesenteric vein of rats was measured on polygraph Letica. Lipid peroxidation in the stomach was assessed using the technique of thiobarbituric acid reactive substances and activity of antioxidant enzymes superoxide dismutase, catalase and glutathione peroxidase. Statistical analysis was done with ANOVA - Student-Newman-Keuls (mean ± SE), and P<0.05 was considered as significant. Portal pressure was significantly increased in C + PPVL as compared to the other groups. There was no significant difference in the group of intact rats. TBARS showed significant damage in C and C + PPVL in relation to others. Antioxidant enzymes were significantly increased in the castrated rats with subsequent PPVL as compared to the other groups. We suggest that estrogen E2 plays a protective role in intact compared with castrated rats because it presents hydrophenolic radicals in its molecule, thus acting as an antioxidant in this experimental model.

  18. Tracks: The New York City Rat Information Portal

    Centers for Disease Control (CDC) Podcasts

    2009-12-21

    This podcast, featuring Daniel Kass, Acting Deputy Commissioner of Environmental Health for the New York City (NYC) Department of Health and Mental Hygiene, provides information about the NYC Rat Information Portal. It details the background and uses of the Rat Portal, as well as next steps for the NYC Environmental Public Health Tracking Program.  Created: 12/21/2009 by National Center for Environmental Health (NCEH).   Date Released: 12/21/2009.

  19. Security Aspects for Business Solution Development on Portal Technology

    OpenAIRE

    Ovidiu R?DU??; Adrian MUNTEANU

    2012-01-01

    In the scope of portal development, in order to talk about security issues, concerns, and solutions, it is necessary to define a few terms: authentication, authorization, Single Sign-On (SSO), confidentiality, integrity, and non-repudiation. Focusing on the scope of what the portal developer and designer need to know, below it will be explained these concepts, considering it is important to define and make a brief analysis of these terms for understanding of achieving the security goals.

  20. Passive nuclear material detection in a personnel portal

    International Nuclear Information System (INIS)

    Fehlau, P.E.; Eaton, M.J.

    1979-01-01

    The concepts employed in the development of gamma-ray and neutron detection systems for a special nuclear materials booth portal monitor are described. The portal is designed for unattended use in detecting diversion by a technically sophisticated adversary and has possible application to International Atomic Energy Agency safeguards of a fast critical assembly facility. Preliminary evaluation results are given and plans for further parameter studies are noted

  1. Survey of Knowledge Management in Portals of Iran Ministries

    OpenAIRE

    Hassan Behzadi; Majideh Sanji

    2012-01-01

    Today, government services or e-government is one of the most important issues in society. Since in the e-government environment, the knowledge management strategy plays a central role, this paper has aimed to study knowledge access, creation, and transfer in portals of Iran ministries. The statistical populations of this study consisted of all Iran ministries portals. An evaluation model known as knowledge access, creation and transfer (K-ACT) was presented and with using this model, a che...

  2. Enterprise Portals und Enterprise Application Integration - Begriffsbestimmung und Integrationskonzeptionen

    OpenAIRE

    Schelp, Joachim; Winter, Robert

    2002-01-01

    Unter den Stichworten »Enterprise Portals« und »Enterprise Application Integration« werden neue Herausforderungen an die Applikationsarchitektur der Unternehmungen gestellt. Bei beiden spielt die Integration vorhandener und das Einfügen neuer Applikationen eine große Rolle. Beiden Themen ist gemein, dass sie die Diskussion bestimmter technischer Konzepte aus den vergangenen Jahren fortsetzen: Portale stellen das moderne Frontend dar, über das die verschiedenen E-Business-Konzepte umgesetzt we...

  3. Cinema ed enogastronomia nel portale turistico della Regione Toscana

    OpenAIRE

    Corinto, Gian Luigi

    2016-01-01

    Il presente lavoro tratta il caso della Regione Toscana che dal 2005 ha affidato alla Fondazione Sistema Toscana la missione di coordinare strategicamente le attività di promozione territoriale, tra cui le attività della film commission e del portale web dedicato al turismo. Lo scopo è quello di analizzare il modello di promozione degli itinerari enogastronomici e cinematografici come presentato dal portale turistico toscano. L'analisi dimostra che la scoperta dell'enogastronomia regionale è ...

  4. Autonomous radiation monitoring of small vessels

    International Nuclear Information System (INIS)

    Ziock, K.P.; Cheriyadat, A.; Fabris, L.; Goddard, J.; Hornback, D.; Karnowski, T.; Kerekes, R.; Newby, J.

    2011-01-01

    Small private vessels are one avenue by which nuclear materials may be smuggled across international borders. While one can contemplate using the land-based approach of radiation portal monitors on the navigable waterways that lead to many ports, these systems are ill-suited to the problem. In contrast to roadways, where lanes segregate vehicles, and motion is well controlled by inspection booths; channels, inlets, and rivers present chaotic traffic patterns populated by vessels of all sizes. A unique solution to this problem is based on a portal-less portal monitor designed to handle free-flowing traffic on roadways with up to five-traffic lanes. The instrument uses a combination of visible-light and gamma-ray imaging to acquire and link radiation images to individual vehicles. This paper presents the results of a recent test of the system in a maritime setting.

  5. Arteriomesentericography in patients with extrahepatic forms of portal hypertension

    International Nuclear Information System (INIS)

    Semenov, V.S.; Gotman, L.N.

    1980-01-01

    The reverse contrast examination of the system, carried out by means of superior arteriomesentericography, is the optimal method for diagnosing pathological changes in the portal channel of splenectomized patients with the syndrome of the extrahepatic form of portal hypertension. The selective catheterization of the superior mesenteric artery was made in 36 patients with the prerenal block of the portal system. In all cases the venous phase of portography was obtained, which served as a basis for selecting the amount of surgical intervention in these patients. Depending on the level of the block of the portal channel, the patients fell into 3 groups. The characteristic X-ray appearance of portal hypertension, manifested mainly by the presence of portoportal and portocaval collaterals, is described for each group. The thrombosis of the main vessels of the loose type of their structure excludes the possibility of portocaval anastomosis, while in the presence of the pronounced surgical trunk of the superior mesenteric vein vascular shunting may be recommended. Portal hypertension, in contrast to the normal state, requires prolonged contrast examination of the venous phase due to a slower portorenal blood flow

  6. Portal-venous gas unrelated to mesenteric ischemia

    International Nuclear Information System (INIS)

    Wiesner, Walter; Mortele, Koenraad J.; Ji, Hoon; Ros, Pablo R.; Glickman, Jonathan N.

    2002-01-01

    The aim of this study was to report on 8 patients with all different non-ischemic etiologies for portal-venous gas and to discuss this rare entity and its potentially misleading CT findings in context with a review of the literature. The CT examinations of eight patients who presented with intrahepatic portal-venous gas, unrelated to bowel ischemia or infarction, were reviewed and compared with their medical records with special emphasis on the pathogenesis and clinical impact of portal-venous gas caused by non-ischemic conditions. The etiologies for portal-venous gas included: abdominal trauma (n=1); large gastric cancer (n=1); prior gastroscopic biopsy (n=1); prior hemicolectomy (n=1); graft-vs-host reaction (n=1); large paracolic abscess (n=1); mesenteric recurrence of ovarian cancer superinfected with clostridium septicum (n=1); and sepsis with Pseudomonas aeruginosa (n=1). The clinical outcome of all patients was determined by their underlying disease and not negatively influenced by the presence of portal-venous gas. Although the presence of portal-venous gas usually raises the suspicion of bowel ischemia and/or intestinal necrosis, this CT finding may be related to a variety of non-ischemic etiologies and pathogeneses as well. The knowledge about these conditions may help to avoid misinterpretation of CT findings, inappropriate clinical uncertainty and unnecessary surgery in certain cases. (orig.)

  7. [Treatment of nontumoral portal vein thrombosis in cirrhosis].

    Science.gov (United States)

    Bañares, Rafael; Catalina, María-Vega

    2014-07-01

    Portal vein thrombosis in cirrhosis is a relatively common complication associated with the presence of an accompanying prothrombotic phenotype of advanced cirrhosis. The consequences of portal vein thrombosis are relevant because it can be associated with impaired hepatic function, might contraindicate hepatic transplantation and could increase morbidity in the surgical procedure. There is controversy concerning the most effective treatment of portal vein thrombosis, which is based on information that is seldom robust and whose primary objective is to achieve a return to vessel patency. Various studies have suggested that starting anticoagulation therapy early is associated with portal vein repatency more frequently than without treatment and has a low rate of complications. There are no proven data on the type of anticoagulant (low-molecular-weight heparins or dicoumarin agents) and the treatment duration. The implementation of TIPS is technically feasible in thrombosis without cavernous transformation and is associated with portal vein recanalization in a significant proportion of cases. Thrombolytic therapy does not appear to present an adequate balance between efficacy and safety; its use is therefore not supported for this indication. The proper definition of treatment for portal vein thrombosis requires properly designed studies to delimit the efficacy and safety of the various alternatives. Copyright © 2014 Elsevier España, S.L. All rights reserved.

  8. Characterization of a high-elbow, fluoroscopic electronic portal imaging device for portal dosimetry

    International Nuclear Information System (INIS)

    Boer, J.C.J. de; Visser, A.G.

    2000-01-01

    The application of a newly developed fluoroscopic (CCD-camera based) electronic portal imaging device (EPID) in portal dosimetry is investigated. A description of the EPID response to dose is presented in terms of stability, linearity and optical cross-talk inside the mechanical structure. The EPID has a relatively large distance (41 cm on-axis) between the fluorescent screen and the mirror (high-elbow), which results in cross-talk with properties quite different from that of the low-elbow fluoroscopic EPIDs that have been studied in the literature. In contrast with low-elbow systems, the maximum cross-talk is observed for points of the fluorescent screen that have the largest distance to the mirror, which is explained from the geometry of the system. An algorithm to convert the images of the EPID into portal dose images (PDIs) is presented. The correction applied for cross-talk is a position-dependent additive operation on the EPID image pixel values, with a magnitude that depends on a calculated effective field width. Deconvolution with a point spread function, as applied for low-elbow systems, is not required. For a 25 MV beam, EPID PDIs and ionization chamber measurements in the EPID detector plane were obtained behind an anthropomorphic phantom and a homogeneous absorber for various field shapes. The difference in absolute dose between the EPID and ionization chamber measurements, averaged over the four test fields presented in this paper, was 0.1±0.5% (1 SD) over the entire irradiation field, with no deviation larger than 2%. (author)

  9. El Parque Portal Bicentenario en Santiago de Chile / Portal Bicentennial Park in Santiago de Chile

    OpenAIRE

    Beach Lobos, Myriam;; Montealegre Klenner, Alberto

    2007-01-01

    Se presenta los principios que orientaron el diseño del Parque Portal Bicentenario, un parque de 50 hás. que será el eje principal de la nueva urbanización “Ciudad Parque Bicentenario”, actualmente en construcción en los terrenos del ex aeropuerto de Los Cerrillos en Santiago de Chile.The following text was submitted to the Architecture Competition together with the project drawings. It presents the principles that leaded the design. The 123 acres park will be the main axis of a new urban dev...

  10. VisPortal: Deploying grid-enabled visualization tools through a web-portal interface

    Energy Technology Data Exchange (ETDEWEB)

    Bethel, Wes; Siegerist, Cristina; Shalf, John; Shetty, Praveenkumar; Jankun-Kelly, T.J.; Kreylos, Oliver; Ma, Kwan-Liu

    2003-06-09

    The LBNL/NERSC Visportal effort explores ways to deliver advanced Remote/Distributed Visualization (RDV) capabilities through a Grid-enabled web-portal interface. The effort focuses on latency tolerant distributed visualization algorithms, GUI designs that are more appropriate for the capabilities of web interfaces, and refactoring parallel-distributed applications to work in a N-tiered component deployment strategy. Most importantly, our aim is to leverage commercially-supported technology as much as possible in order to create a deployable, supportable, and hence viable platform for delivering grid-based visualization services to collaboratory users.

  11. Porto-systemic collaterals in cirrhosis of the liver. Selective percutaneous transhepatic catheterization of the portal venous system in portal hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Hoevels, J; Lunderquist, A; Tylen, U; Simert, G [Lund Univ. (Sweden)

    1979-01-01

    In 93 patients with cirrhosis of the liver and portal venous hypertension the main tributaries of the portal vein were examined by percutaneous transhepatic catheterization. The appearance and degree of porto-systemic collaterals were analysed. Esophageal varices were demonstrated in 82 patients. No correlation was found between the portal venous pressure and the extent of porto-systemic communications.

  12. Higgs portal valleys, stability and inflation

    CERN Document Server

    Ballesteros, Guillermo

    2015-01-01

    The measured values of the Higgs and top quark masses imply that the Standard Model potential is very likely to be unstable at large Higgs values. This is particularly problematic during inflation, which sources large perturbations of the Higgs. The instability could be cured by a threshold effect induced by a scalar with a large vacuum expectation value and directly connected to the Standard Model through a Higgs portal coupling. However, we find that in a minimal model in which the scalar generates inflation, this mechanism does not stabilize the potential because the mass required for inflation is beyond the instability scale. This conclusion does not change if the Higgs has a direct weak coupling to the scalar curvature. On the other hand, if the potential is absolutely stable, successful inflation in agreement with current CMB data can occur along a valley of the potential with a Mexican hat profile. We revisit the stability conditions, independently of inflation, and clarify that the threshold effect ca...

  13. DESM: portal for microbial knowledge exploration systems

    KAUST Repository

    Salhi, Adil

    2015-11-05

    Microorganisms produce an enormous variety of chemical compounds. It is of general interest for microbiology and biotechnology researchers to have means to explore information about molecular and genetic basis of functioning of different microorganisms and their ability for bioproduction. To enable such exploration, we compiled 45 topic-specific knowledgebases (KBs) accessible through DESM portal (www.cbrc.kaust.edu.sa/desm). The KBs contain information derived through text-mining of PubMed information and complemented by information data-mined from various other resources (e.g. ChEBI, Entrez Gene, GO, KOBAS, KEGG, UniPathways, BioGrid). All PubMed records were indexed using 4 538 278 concepts from 29 dictionaries, with 1 638 986 records utilized in KBs. Concepts used are normalized whenever possible. Most of the KBs focus on a particular type of microbial activity, such as production of biocatalysts or nutraceuticals. Others are focused on specific categories of microorganisms, e.g. streptomyces or cyanobacteria. KBs are all structured in a uniform manner and have a standardized user interface. Information exploration is enabled through various searches. Users can explore statistically most significant concepts or pairs of concepts, generate hypotheses, create interactive networks of associated concepts and export results. We believe DESM will be a useful complement to the existing resources to benefit microbiology and biotechnology research.

  14. Building a Stückelberg portal

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Wan-Zhe [Center for Fundamental Physics and Institute for Advanced Study,Hong Kong University of Science and Technology (Hong Kong); Max-Planck-Institut für Physik (Werner-Heisenberg-Institut),80805 München (Germany); Shiu, Gary; Soler, Pablo; Ye, Fang [Center for Fundamental Physics and Institute for Advanced Study,Hong Kong University of Science and Technology (Hong Kong); Department of Physics, University of Wisconsin,Madison, WI 53706 (United States)

    2014-05-15

    We construct explicit string theory models realizing the recently proposed “Stückelberg Portal” scenario, a framework for building Z{sup ′} mediation models without the need to introduce unwanted exotic matter charged under the Standard Model. This scenario can be viewed purely field-theoretically, although it is particularly well motivated from string theory. By analyzing carefully the Stückelberg couplings between the Abelian gauge bosons and the RR axions, we construct the first global intersecting brane models which extend the Standard Model with a genuine hidden sector, to which it is nonetheless connected via U(1) mass mixings. Utilizing the explicit models we construct, we discuss some broad phenomenological properties and experimental implications of this scenario such as Z−Z{sup ′} mixings, dark matter stability and relic density, and supersymmetry mediation. With an appropriate confining hidden sector, our setup also provides a minimal realization of the hidden valley scenario. We further explore the possibility of obtaining small Z{sup ′} masses from a large ensemble of U(1) bosons. Related to the Stückelberg portal are two mechanisms that connect the visible and the hidden sectors, namely mediation by non-perturbative operators and the hidden photon scenario, on which we briefly comment.

  15. Combating the counterfeits with web portal technology

    Science.gov (United States)

    Ting, S. L.; Ip, W. H.

    2015-10-01

    Due to the globalisation of counterfeiting activities, the penetration of fake products in open market is growing. So far, the technologies to combat counterfeiting are mostly applied to high-value products (e.g. premium wine and branded handbags); however, in the medium- and low-value products' perspective, there is no secure way for consumers to identify whether the purchased items are genuine or not. To address the counterfeiting problems effectively, a platform for identifying authenticated products and promoting anti-counterfeit activities is very important. The aim of this paper is to design and develop an anti-counterfeit platform which includes two functions: providing customers a secure network to ascertain the genuineness of their purchased product and increasing public awareness of the current counterfeit problems and updated anti-counterfeit solutions. By combining these two functions, it enables public to fight against fake and beware of counterfeit. Results of adopting portal technology in anti-counterfeiting show high accuracy in product checking and improved creditability. This reveals that the applicability and advantage of the proposed methodology are satisfactory.

  16. Knowledge portal for Six Sigma DMAIC process

    Science.gov (United States)

    ThanhDat, N.; Claudiu, K. V.; Zobia, R.; Lobont, Lucian

    2016-08-01

    Knowledge plays a crucial role in success of DMAIC (Define, Measure, Analysis, Improve, and Control) execution. It is therefore necessary to share and renew the knowledge. Yet, one problem arising is how to create a place where knowledge are collected and shared effectively. We believe that Knowledge Portal (KP) is an important solution for the problem. In this article, the works concerning with requirements and functionalities for KP are first reviewed. Afterwards, a procedure with necessary tools to develop and implement a KP for DMAIC (KPD) is proposed. Particularly, KPD is built on the basis of free and open-source content and learning management systems, and Ontology Engineering. In order to structure and store knowledge, tools such as Protégé, OWL, as well as OWL-RDF Parsers are used. A Knowledge Reasoner module is developed in PHP language, ARC2, MySQL and SPARQL endpoint for the purpose of querying and inferring knowledge available from Ontologies. In order to validate the availability of the procedure, a KPD is built with the proposed functionalities and tools. The authors find that the KPD benefits an organization in constructing Web sites by itself with simple steps of implementation and low initial costs. It creates a space of knowledge exchange and supports effectively collecting DMAIC reports as well as sharing knowledge created. The authors’ evaluation result shows that DMAIC knowledge is found exactly with a high success rate and a good level of response time of queries.

  17. Intranet portal at the Krsko NPP, Slovenia

    International Nuclear Information System (INIS)

    2016-01-01

    The intranet portal (named IntraNEK) at Krsko NPP serves as a single entry point to access the internet and various plant applications and links. The front page consists of the standard internet search bar and links to various applications that can either reside within the technological computer network (TRM) or within the plant business computer network. Access to the TRM applications is read only. Some applications on the business computer network are open to all personnel who log on to the network while some applications are restricted and secured, and require additional login entries. A selected link will open in a new window. Documents will open with the appropriate software tool depending on the document file format. Some categories of documents are available in image form only (e.g. procedures, drawings etc.), while some are available in fully searchable PDF format (e.g. technical specifications, updated safety analysis reports (USARs) etc.). Plant departments (organizational units) have their own pages accessible from the front page. Their pages contain links to their own information resources or links to other resources and applications, tailored to the department needs. During recent years a number of web based applications have been developed that are connected also with a common Oracle database. Some are designed to serve for data entry and browsing while others serve for browsing only

  18. Radiation Detection for Homeland Security Applications

    Science.gov (United States)

    Ely, James

    2008-05-01

    In the past twenty years or so, there have been significant changes in the strategy and applications for homeland security. Recently there have been significant at deterring and interdicting terrorists and associated organizations. This is a shift in the normal paradigm of deterrence and surveillance of a nation and the `conventional' methods of warfare to the `unconventional' means that terrorist organizations resort to. With that shift comes the responsibility to monitor international borders for weapons of mass destruction, including radiological weapons. As a result, countries around the world are deploying radiation detection instrumentation to interdict the illegal shipment of radioactive material crossing international borders. These efforts include deployments at land, rail, air, and sea ports of entry in the US and in European and Asian countries. Radioactive signatures of concern include radiation dispersal devices (RDD), nuclear warheads, and special nuclear material (SNM). Radiation portal monitors (RPMs) are used as the main screening tool for vehicles and cargo at borders, supplemented by handheld detectors, personal radiation detectors, and x-ray imaging systems. This talk will present an overview of radiation detection equipment with emphasis on radiation portal monitors. In the US, the deployment of radiation detection equipment is being coordinated by the Domestic Nuclear Detection Office within the Department of Homeland Security, and a brief summary of the program will be covered. Challenges with current generation systems will be discussed as well as areas of investigation and opportunities for improvements. The next generation of radiation portal monitors is being produced under the Advanced Spectroscopic Portal program and will be available for deployment in the near future. Additional technologies, from commercially available to experimental, that provide additional information for radiation screening, such as density imaging equipment, will

  19. Blood in the gastric lumen increases splanchnic blood flow and portal pressure in portal-hypertensive rats.

    Science.gov (United States)

    Chen, L; Groszmann, R J

    1996-10-01

    In portal-hypertensive humans, portal blood flow and pressure increase after a meal. These hemodynamic changes may increase variceal rupture risk. The aim of this study was to determine whether blood in the stomach lumen increases splanchnic flow and portal pressure (PP) in portal-hypertensive rats. superior mesenteric artery flow and PP were measured in conscious, unrestrained, fasted partial portal vein-ligated rats with chronically implanted Doppler flow probes or portal vein catheters before and after gavage with heparinized, warmed blood from donor rats, air, standard meal, or empty tube. Percentage of changes in flow and pressure from baseline were significantly greater after gavage with blood (an increase of 22.6% +/- 3.5% and an increase of 16.4% +/- 3.1%, respectively) than empty tube (an increase of 3.4% +/- 0.6% and a decrease of 5.4% +/- 3.5%, respectively) (P empty tube (P calories probably contributes to these hemodynamic changes. In patients with variceal hemorrhage, blood in the stomach may increase the risk of persistent variceal bleeding or rebleeding.

  20. Portfolio: a prototype workstation for development and evaluation of tools for analysis and management of digital portal images

    International Nuclear Information System (INIS)

    Boxwala, Aziz A.; Chaney, Edward L.; Fritsch, Daniel S.; Friedman, Charles P.; Rosenman, Julian G.

    1998-01-01

    Purpose: The purpose of this investigation was to design and implement a prototype physician workstation, called PortFolio, as a platform for developing and evaluating, by means of controlled observer studies, user interfaces and interactive tools for analyzing and managing digital portal images. The first observer study was designed to measure physician acceptance of workstation technology, as an alternative to a view box, for inspection and analysis of portal images for detection of treatment setup errors. Methods and Materials: The observer study was conducted in a controlled experimental setting to evaluate physician acceptance of the prototype workstation technology exemplified by PortFolio. PortFolio incorporates a windows user interface, a compact kit of carefully selected image analysis tools, and an object-oriented data base infrastructure. The kit evaluated in the observer study included tools for contrast enhancement, registration, and multimodal image visualization. Acceptance was measured in the context of performing portal image analysis in a structured protocol designed to simulate clinical practice. The acceptability and usage patterns were measured from semistructured questionnaires and logs of user interactions. Results: Radiation oncologists, the subjects for this study, perceived the tools in PortFolio to be acceptable clinical aids. Concerns were expressed regarding user efficiency, particularly with respect to the image registration tools. Conclusions: The results of our observer study indicate that workstation technology is acceptable to radiation oncologists as an alternative to a view box for clinical detection of setup errors from digital portal images. Improvements in implementation, including more tools and a greater degree of automation in the image analysis tasks, are needed to make PortFolio more clinically practical