WorldWideScience

Sample records for radiation meter type

  1. Instrument evaluation no. 10. Scanray radiation meter type 751

    CERN Document Server

    Burgess, P H; White, D F

    1978-01-01

    The various radiations encountered in radiological protection cover a wide range of energies and radiation measurements have to be carried out under an equally broad spectrum of environmental conditions. This report is one of a series intended to give information on the performance characteristics of radiological protection instruments, to assist in the selection of appropriate instruments for a given purpose, to interpret the results obtained with such instruments, and, in particular, to know the likely sources and magnitude of errors that might be associated with measurements in the field. The radiation, electrical and environmental characteristics of radiation protection instruments are considered together with those aspects of the construction which make an instrument convenient for routine use. To provide consistent criteria for instrument performance, the range of tests performed on any particular class of instrument, the test methods and the criteria of acceptable performance are based broadly on the a...

  2. Arduino based radiation survey meter

    Energy Technology Data Exchange (ETDEWEB)

    Rahman, Nur Aira Abd, E-mail: nur-aira@nm.gov.my; Lombigit, Lojius; Abdullah, Nor Arymaswati; Azman, Azraf; Dolah, Taufik; Jaafar, Zainudin; Mohamad, Glam Hadzir Patai; Ramli, Abd Aziz Mhd; Zain, Rasif Mohd; Said, Fazila; Khalid, Mohd Ashhar; Taat, Muhamad Zahidee [Malaysian Nuclear Agency, 43000, Bangi, Selangor (Malaysia); Muzakkir, Amir [Sinaran Utama Teknologi Sdn Bhd, 43650, Bandar Baru Bangi, Selangor (Malaysia)

    2016-01-22

    This paper presents the design of new digital radiation survey meter with LND7121 Geiger Muller tube detector and Atmega328P microcontroller. Development of the survey meter prototype is carried out on Arduino Uno platform. 16-bit Timer1 on the microcontroller is utilized as external pulse counter to produce count per second or CPS measurement. Conversion from CPS to dose rate technique is also performed by Arduino to display results in micro Sievert per hour (μSvhr{sup −1}). Conversion factor (CF) value for conversion of CPM to μSvhr{sup −1} determined from manufacturer data sheet is compared with CF obtained from calibration procedure. The survey meter measurement results are found to be linear for dose rates below 3500 µSv/hr.

  3. Radiation survey meters used for environmental monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Bjerke, H. (ed.) (Norwegian Radiation Protection Authority, NRPA (Norway)); Sigurdsson, T. (Icelandic Radiation Safety Authority, Geislavarnir Rikisins, GR (IS)); Meier Pedersen, K. (National Board of Health, Statens Institut for Straalebeskyttelse (SIS) (Denmark)); Grindborg, J.-E.; Persson, L. (Swedish Radiation Safety Authority, Straalsaekerhetsmyndigheten (SSM) (Sweden)); Siiskonen, T.; Hakanen, A.; Kosunen, A. (Radiation and Nuclear Safety Authority, Saeteilyturvakeskus (STUK) (Finland))

    2012-01-15

    The Nordic dosimetry group set up the GammaRate project to investigate how its expertise could be used to assure appropriate usage of survey meters in environmental monitoring. Considerable expertise in calibrating radiation instruments exists in the Nordic radiation protection authorities. The Swedish, Finnish, Danish and Norwegian authorities operate Secondary Standard Dosimetry Laboratories (SSDLs) that provide users with calibration traceable to internationally recognised primary standards. These authorities together with the Icelandic authorities have formally cooperated since 2002 in the field of radiation dosimetry. Dosimetry is the base for assesment of risk from ionising radiation and calibration of instruments is an imported part in dosimetry. The Nordic dosimetry group has been focused on cancer therapy. This work extends the cooperation to the dosimetry of radiation protection and environmental monitoring. This report contains the formal, theoretical and practical background for survey meter measurements. Nordic standards dosimetry laboratories have the capability to provide traceable calibration of instruments in various types of radiation. To verify and explore this further in radiation protection applications a set of survey instruments were sent between the five Nordic countries and each of the authority asked to provide a calibration coefficient for all instruments. The measurement results were within the stated uncertainties, except for some results from NRPA for the ionchamber based instrument. The comparison was shown to be a valuable tool to harmonize the calibration of radiation protection instruments in the Nordic countries. Dosimetry plays an important role in the emergency situations, and it is clear that better traceability and harmonised common guidelines will improve the emergency preparedness and health. (Author)

  4. Use of portable exposure meters for comparing mobile phone base station radiation in different types of areas in the cities of Basel and Amsterdam.

    Science.gov (United States)

    Urbinello, Damiano; Huss, Anke; Beekhuizen, Johan; Vermeulen, Roel; Röösli, Martin

    2014-01-15

    Radiofrequency electromagnetic fields (RF-EMF) are highly variable and differ considerably within as well as between areas. Exposure assessment studies characterizing spatial and temporal variation are limited so far. Our objective was to evaluate sources of data variability and the repeatability of daily measurements using portable exposure meters (PEMs). Data were collected at 12 days between November 2010 and January 2011 with PEMs in four different types of urban areas in the cities of Basel (BSL) and Amsterdam (AMS). Exposure from mobile phone base stations ranged from 0.30 to 0.53 V/m in downtown and business areas and in residential areas from 0.09 to 0.41 V/m. Analysis of variance (ANOVA) demonstrated that measurements from various days were highly reproducible (measurement duration of approximately 30 min) with only 0.6% of the variance of all measurements from mobile phone base station radiation being explained by the measurement day and only 0.2% by the measurement time (morning, noon, afternoon), whereas type of area (30%) and city (50%) explained most of the data variability. We conclude that mobile monitoring of exposure from mobile phone base station radiation with PEMs is useful due to the high repeatability of mobile phone base station exposure levels, despite the high spatial variation. © 2013.

  5. Performance of radiation survey meters in X- and gamma-radiation fields.

    Science.gov (United States)

    Ceklic, Sandra; Arandjic, Danijela; Zivanovic, Milos; Ciraj-Bjelac, Olivera; Lazarevic, Djordje

    2014-11-01

    The aim of this work was to investigate the different types of radiation detectors commonly used for radiation protection purposes as survey meters. The study was performed on survey meters that use different detectors as ionisation chamber, Geiger Mueller (GM) counter and scintillation detector. For each survey meter, energy dependence and angular response in X- and gamma-radiation fields was tested. The following commercially available survey meters were investigated: ionisation chambers Victoreen 451P, Babyline 31 and VA-J-15A, Geiger counter MRK-M87, 6150 AD6 and FAG FH 40F2 and scintillation counter 6150 ADB. As a source of gamma radiation, (137)Cs and (60)Co were used whereas X-ray radiation fields were generated using an X-ray unit. The radiation characteristics of the survey meters were mostly in compliance with references estimated by standard IEC 1017-2. However, some of them showed larger deviation at lower energies. GM counters exhibit strong energy dependence for low-energy photons. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. Suppression of radiated emission in fiscal taxi meter

    Science.gov (United States)

    He, Hong; Yang, Pei-pei; Su, Xing; Zhang, Da-jian; Wang, Ke-xi; Hou, Ming-feng

    2011-12-01

    This paper is based upon National Standards for EMC. For the problem that the intensity of electromagnetic radiation in the meter with the THG at 36MHz is seriously more than National Standards, by studying the theory of radiation emission and analyzing the formation mechanism of electromagnetic radiation interference, it proposes three restrain measures: 1.the improvement of the Crystal oscillator's grounding measure; 2.adding a RC filter circuit to the Crystal oscillator circuit; 3.the improvement of the tax's communication cable, solving the problem that radiation harassment the taxi meter seriously exceeds. The experimental result demonstrates that the radiation intensity of tax meter improved with the general measures meet the requirements of the national standard, making more than 32000 taxes in Tianjin install this green meter, protecting the safety of staff and normal operation of the surrounding equipment.

  7. Do dose area product meter measurements reflect radiation doses ...

    African Journals Online (AJOL)

    Enrique

    between radiation doses absorbed by health care workers and dose area product meter (DAP) measurements at Universitas Hospital, Bloemfontein. The DAP is an instrument which accurately measures the radiation emitted from the source. The study included the interventional radiolo- gists, radiographers and nurses ...

  8. Mass flow meter of the Coriolis type

    NARCIS (Netherlands)

    Mehendale, A.; Lötters, Joost Conrad; Lotters, Joost Conrad; Zwikker, Jan Marinus

    2006-01-01

    A mass flowmeter of the Coriolis type with a tube that forms a mechanically closed loop through which a medium flows during operation, and with excitation means for causing the loop to rotate in an oscillatory mode about an axis of rotation during operation. The loop has a starting point and an end

  9. Design and calibration of a novel transient radiative heat flux meter for a spacecraft thermal test.

    Science.gov (United States)

    Sheng, Chunchen; Hu, Peng; Cheng, Xiaofang

    2016-06-01

    Radiative heat flux measurement is significantly important for a spacecraft thermal test. To satisfy the requirements of both high accuracy and fast response, a novel transient radiative heat flux meter was developed. Its thermal receiver consists of a central thermal receiver and two thermal guarded annular plates, which ensure the temperature distribution of the central thermal receiver to be uniform enough for reasonably applying lumped heat capacity method in a transient radiative heat flux measurement. This novel transient radiative heat flux meter design can also take accurate measurements regardless of spacecraft surface temperature and incident radiation spectrum. The measurement principle was elaborated and the coefficients were calibrated. Experimental results from testing a blackbody furnace and an Xenon lamp show that this novel transient radiative heat flux meter can be used to measure transient radiative heat flux up to 1400 W/m(2) with high accuracy and the response time of less than 10 s.

  10. Do dose area product meter measurements reflect radiation doses ...

    African Journals Online (AJOL)

    Enrique

    accurately measures the radiation emitted from the source. The study included the interventional radiolo ... mined as most sensitive to radiation. The use of a thyroid guard also decreases the effective dose by approx- ... al radiation is necessary. Thermo- luminescent dosimetry is used to measure radiation and the apparatus.

  11. Instrument evaluation no. 33. Automess Szintomat 6134 radiation survey meter

    CERN Document Server

    McClure, D R

    1986-01-01

    The various radiations encountered in radiological protection cover a wide range of energies and radiation measurements have to be carried out under an equally broad spectrum of environmental conditions. This report is one of a series intended to give information on the performance characteristics of radiological protection instruments, to assist in the selection of appropriate instruments for a given purpose, to interpret the results obtained with such instruments, and, in particular, to know the likely sources and magnitude of errors that might be associated with measurements in the field. The radiation, electrical and environmental characteristics of radiation protection instruments are considered together with those aspects of the construction which make an instrument convenient for routine use. To provide consistent criteria for instrument performance, the range of tests performed on any particular class of instrument, the test methods and the criteria of acceptable performance are based broadly on the a...

  12. Portable meter study of ionizing radiation Teletector in high rates of air kerma

    Energy Technology Data Exchange (ETDEWEB)

    Damatto, Willian Behling; Potiens, Maria da Penha A.; Vivolo, Vitor, E-mail: willbdamatto@gmail.com [Instituto de Pesquisas Energeticas e Nucleres (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    A set of portable meters of ionizing radiation high rates of air kerma (teletectors) commonly used in emergencies in Brazil and sent to the Calibration Laboratory of IPEN were under several tests and analyst is parameters for the detectors behavior were established. Applied tests were: energy dependence and primarily overload with the new irradiation system. Thus it was possible to determine the most common characteristic found in these equipment (quality control programs) and new calibration criteria were established following international recommendations. (author)

  13. Problems Associated with the Use of the Radiochromic Dye Film as a Radiation Dose Meter

    DEFF Research Database (Denmark)

    Hansen, Johnny; Wille, Mads; Olsen, Kjeld J.

    1984-01-01

    A thorough investigation has been made of the problems involved in using a dye film dose meter for precision dosimetry at high doses, using both low- and high-LET radiation. The study includes: time course of coloration following irradiation at various dose levels; dose response after irradiation...... of coloration. The dose response has been found to depend strongly on: the time span between irradiation and measurement; the irradiation temperature; and the dose rate at doses above 50 kGy for low-LET radiation. Irradiation in vacuum (right-pointing angle bracket1 Pa) and in air produced the same dose...

  14. Open-channel integrating-type flow meter

    Science.gov (United States)

    Koopman, K.C.

    1971-01-01

    A relatively inexpensive meter for measuring cumulative flow in open channels with a rated control,. called a "totalizer", was developed. It translates the nonlinear function of gage height to flow by use of a cam and a float. A variable resistance element in an electronic circuit is controlled by the float so that the electron flow in the circuit corresponds to the flow of water. The flow of electricity causes electroplating of an electrode with silver. The amount of silver deposited is proportionate to the flow of water. The total flow of water is determined by removing the silver from the electrode at a fixed rate with ·an electronic device and recording the time for removal with a counter. The circuit is designed so that the ,resultant reading on the counter is in acre-feet of water.

  15. Determination of scattered gamma radiation in the calibration of environmental dose rate meters

    DEFF Research Database (Denmark)

    Bøtter-Jensen, L.; Hedemann Jensen, P.

    1992-01-01

    Practical free-field and shadow-shield calibration techniques using a variety of environmental dose rate meters were studied, and experimental and theoretical determinations were made of the contribution of scattered photons to the air kerma rate from certificated Cs-137, Co-60 and Ra-226 gamma...... negligibly to the detector response relative to that from ground and air. Shadow-shield measurements were used to deduce the contribution to the response from the scattered radiation in free-field geometries and the experimentally obtained results were found to agree agree extremely well with those...... the detector responses. Insignificant differences of the order of 1 % between the results for the two geometries were found both experimentally and theoretically. It is thus concluded that the scattered radiation from surrounding buildings farther away than around 15 m from a calibration set-up contributes...

  16. Conception of thermoelectric flux meters for infrared radiation measurements in industrial furnaces

    Energy Technology Data Exchange (ETDEWEB)

    Ploteau, J.P. [Laboratoire LET2E, Universite de Bretagne Sud, Centre de Recherche, Rue St Maude, BP 92116, 56321 Lorient Cedex (France)]. E-mail: jean-pierre.ploteau@univ-ubs.fr; Glouannec, P. [Laboratoire LET2E, Universite de Bretagne Sud, Centre de Recherche, Rue St Maude, BP 92116, 56321 Lorient Cedex (France); Noel, H. [Laboratoire LET2E, Universite de Bretagne Sud, Centre de Recherche, Rue St Maude, BP 92116, 56321 Lorient Cedex (France)

    2007-02-15

    To help optimise the design and command of infrared (IR) emitters which are frequently used in industrial installations [A.C. Metaxas, Foundations of Electro-Heat a Unified Approach, John Wiley, Chichester, 1996; H. Lihan, Infrared surface pasteurisation of Turkey frankfurters, Innovative Food Science and Emerging Technologies 5 (3) (2004) 345-351; F.M. Schmidt, Y. Le Maoult, S. Monteix, Modelling of infrared heating of thermoplastic sheet used in thermoforming process, Journal of Materials Processing Technology 143-144 (2003) 225-231; M.T. Brogan, P.F. Monaghan, Thermal simulation of quartz tube infrared heaters used in the processing of thermoplastic composites, Composites Part A: Applied Science and Manufacturing 27 (4) (1996) 301-306; S. Le Person, J.R. Puiggali, M. Baron, M. Roques, Near infrared drying of pharmaceutical thin films: experimental analysis of internal mass transport, Chemical Engineering and Processing 37 (3) (1998) 257-263; K. Esser, E. Haberstroh, U. Huesgen, D. Weinand, Infrared radiation in the processing of plastics: precise adjustment-the key to productivity, Advances in Polymer Technology 7 (2) (1987) 89-128; D. Blanc, P. Laurent, J. Andrieu, J.F. Gerard, Convective and radiant (IR) curing of bulk and waterborne epoxy coatings as thin layers, part II: infrared curing polymer, Engineering and Science 39 (12) (1999) 2487-2497], this paper aims at presenting the development, the construction, the calibration, and the test of flux meters designed to make 'in situ' measurements of infrared radiation in industrial furnaces. These sensors must be able to measure high heat flux in difficult thermal ambiances, and be adapted to the characterization of existing processes, therefore the output signal has to directly reflect the IR received flux. The sensible part is made with a semiconductor thermoelectric module which offers a great sensitivity. While the top part of the module is exposed to convection and infrared radiation, the bottom

  17. Evaluation of patient radiation doses using DAP meter in interventional radiology procedures

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Byung Sam [Dept. of Radiological Technology. Shingu University, Sungnam (Korea, Republic of); Yoon, Yong Su [Dept. of Health Sciences, Graduate School of Medical Sciences, Kyushu Univeristy, Kyushu (Japan)

    2017-03-15

    The author investigated interventional radiology patient doses in several other countries, assessed accuracy of DAP meters embedded in intervention equipment in domestic country, conducted measurement of patient doses for 13 major interventional procedures with use of Dose Area Product(DAP) meters from 23 hospitals in Korea, and referred to 8,415 cases of domestic data related to interventional procedures by radiation exposure after evaluation the actual effective of dose reduction variables through phantom test. Finally, dose reference level for major interventional procedures was suggested. In this study, guidelines for patient doses were 237.7 Gy·cm{sup 2} in TACE, 17.3 Gy·cm{sup 2} in AVF, 114.1 Gy·cm{sup 2} in LE PTA and STENT, 188.5 Gy·cm{sup 2} in TFCA, 383.5 Gy·cm{sup 2} in Aneurysm Coil, 64.6 Gy·cm{sup 2} in PTBD, 64.6 Gy·cm{sup 2} in Biliary Stent, 22.4 Gy·cm{sup 2} in PCN, 4.3 Gy·cm{sup 2} in Hickman, 2.8 Gy·cm{sup 2} in Chemo-port, 4.4 Gy·cm{sup 2} in Perm-Cather, 17.1 Gy·cm{sup 2} in PCD, and 357.9 Gy·cm{sup 2} in Vis, EMB. Dose reference level acquired in this study is considered to be able to use as minimal guidelines for reducing patient dose in the interventional radiology procedures. For the changes and advances of materials and development of equipment and procedures in the interventional radiology procedures, further studies and monitoring are needed on dose reference level Korean DAP dose conversion factor for the domestic procedures.

  18. Assessment of a relative contribution of terrestrial background radiation in the test field by using RADIAGEMTM 2000 portable survey meter

    Directory of Open Access Journals (Sweden)

    Avdić Senada

    2016-01-01

    Full Text Available This study is focused on the radiological investigation of terrestrial gamma radiation in the test field with soil samples from different minefields in the Federation of Bosnia and Herzegovina. Measurements of ambient dose equivalent rate, commonly referred to as “air dose rate”, in the test field located in the Tuzla Canton, were performed by RADIAGEMTM 2000 portable survey meter, based on energy-compensated Geiger-Muller counter. Its performances were tested in the laboratory conditions with gamma point sources. Since all the samples in the test field were exposed to the same cosmic radiation, there was a possibility to assess a relative contribution of terrestrial gamma radiation due to soil samples of different composition. One set of measurements in the test field was performed with RADIAGEMTM 2000, at a height of about one meter above the ground and basic statistical parameters indicated that there was no significant difference of terrestrial gamma radiation from different soil samples. The other set of measurements was carried out with the same device placed on the ground in the test field. Processing of experimental data on terrestrial gamma radiation has shown that it was possible to make a difference between relative contributions of terrestrial gamma radiation from individual soil samples. The results of investigation could be useful for multiple purposes of public interest.

  19. Calibration and use of continuous heat-type automated seepage meters for submarine groundwater discharge measurements

    Science.gov (United States)

    Mwashote, B.M.; Burnett, W.C.; Chanton, J.; Santos, I.R.; Dimova, N.; Swarzenski, P.W.

    2010-01-01

    Submarine groundwater discharge (SGD) assessments were conducted both in the laboratory and at a field site in the northeastern Gulf of Mexico, using a continuous heat-type automated seepage meter (seepmeter). The functioning of the seepmeter is based on measurements of a temperature gradient in the water between downstream and upstream positions in its flow pipe. The device has the potential of providing long-term, high-resolution measurements of SGD. Using a simple inexpensive laboratory set-up, we have shown that connecting an extension cable to the seepmeter has a negligible effect on its measuring capability. Similarly, the observed influence of very low temperature (???3 ??C) on seepmeter measurements can be accounted for by conducting calibrations at such temperatures prior to field deployments. Compared to manual volumetric measurements, calibration experiments showed that at higher water flow rates (>28 cm day-1 or cm3 cm-2 day-1) an analog flowmeter overestimated flow rates by ???7%. This was apparently due to flow resistance, turbulence and formation of air bubbles in the seepmeter water flow tubes. Salinity had no significant effect on the performance of the seepmeter. Calibration results from fresh water and sea water showed close agreement at a 95% confidence level significance between the data sets from the two media (R2 = 0.98). Comparatively, the seepmeter SGD measurements provided data that are comparable to manually-operated seepage meters, the radon geochemical tracer approach, and an electromagnetic (EM) seepage meter. ?? 2009 Elsevier Ltd.

  20. Calibration and features of air-kerma length product meters.

    Science.gov (United States)

    Merimaa, K; Tapiovaara, M; Kosunen, A; Toroi, P

    2012-12-01

    Pencil-type air-kerma length product meters are generally used for quality control and radiation exposure measurements in computed tomography. To ensure reliable results, these meters should be calibrated so that measurements are traceable to international standards. Suitable calibration procedures, together with the properties of these meters, were examined and compared with the international standards and recommendations. The calibration procedure and setup used in this study were slightly modified compared with international recommendations. The special collimator system was found to cause less scatter than similar setups in earlier studies. The energy dependence of the meter response was investigated for several types of meters with standard radiation qualities. With most tested meter types, the total variation due to energy dependence was meter type varied up to 8 % when rotating the meter around its axis; this should be taken into account when making calibrations with a static setup.

  1. An international intercomparison of passive dosemeters, electronic dosemeters and dose rate meters used for environmental radiation measurements

    DEFF Research Database (Denmark)

    Bøtter-Jensen, L.; Thompson, I.M.G.

    1995-01-01

    To assist towards the harmonisation within the EC countries, the Eastern European countries and the USA, of the measurement of environmental dose rates from photon radiation an EC sponsored intercomparison of environmental dose rate meters, electronic dosemeters and TL dosemeters was performed...... Measurement Stations during the period 12 to 18 June 1994. The chief aims of the experiments were to allow the participants to check their home calibrations of their detectors and to intercompare the dosemeter responses of the individual environmental radiation measurement systems used in the USA, Eastern...

  2. Optical cycle power meter

    DEFF Research Database (Denmark)

    2014-01-01

    A bicycle power meter for measuring power generated when riding a bicycle, the power meter comprising a position-sensitive radiation detector (409) attachable to a component of a crank set (404) of bicycle, and a radiation source (408) attachable to the component of the crank set and configured...

  3. Interaction of soft x-ray laser pulse radiation with aluminum surface: Nano-meter size surface modification

    Energy Technology Data Exchange (ETDEWEB)

    Ishino, Masahiko; Faenov, Anatoly; Tanaka, Momoko; Hasegawa, Noboru; Nishikino, Masaharu; Tamotsu, Satoshi; Pikuz, Tatiana; Inogamov, Nail; Zhakhovsky, Vasily; Skobelev, Igor; Fortov, Vladimir; Khohlov, Viktor; Shepelev, Vadim; Ohba, Toshiyuki; Kaihori, Takeshi; Ochi, Yoshihiro; Imazono, Takashi; Kawachi, Tetsuya [Quantum Beam Science Directorate, Japan Atomic Energy Agency, Kyoto 619-0215 (Japan); Joint Institute for High Temperatures, Russian Academy of Science, Moscow 125412 (Russian Federation); Graduate School of Humanities and Science, Nara Women' s University, Nara 630-8506 (Japan); Landau Institute for Theoretical Physics, Russian Academy of Science, Chernogolovka 142432 (Russian Federation); Institute for Computer Aided Design, Russian Academy of Science, Moscow 123056 (Russian Federation)

    2012-07-11

    Interaction of soft x-ray laser radiation with material and caused modification of the exposed surface has both physical and practical interests. We irradiated the focusing soft x-ray laser (SXRL) pulses having a wavelength of 13.9 nm and the duration of 7 ps to aluminum (Al) surface. After the SXRL irradiation process, the irradiated Al surface was observed with a scanning electron microscope. The surface modifications caused by SXRL single pulse exposure were clearly seen. In addition, it was found that the conical structures having around 100 nm in diameters were formed in the shallow features. The nano-meter size modified structures at Al surface induced by SXRL pulse is interesting as the newly surface structure. Hence, the SXRL beam would be a candidate for a tool of micromachining. We also provide a thermomechanical modeling of SXRL interaction with Al briefly to explain the surface modification.

  4. DNA Radiation Environments Program - Spring 1990 2-meter box experiments and analyses

    Energy Technology Data Exchange (ETDEWEB)

    Santoro, R.T (Oak Ridge National Lab., TN (United States)); Whitaker, S.Y. (Clark Atlanta Univ., GA (United States))

    1992-09-01

    This report summarizes the Spring 1990 2-m Box Experiments performed at the Army Pulse Radiation Facility (APRF) at Aberdeen Proving Ground, Maryland. These studies were sponsored by the Defense Nuclear Agency (DNA) under the Radiation Environments Program to obtain measured data for benchmarking the Adjoint Monte Carlo Code System, MASH, Version 1.0. MASH was developed as the Department of Defense and NATO code system for calculating neutron and gamma-ray radiation fields and shielding protection factors for armored vehicles and military structures against nuclear weapon radiation. In the experiments, neutron and gamma-ray dose and reduction factors were measured in the free-field and as a function of position on an anthropomorphic phantom that was placed outside and inside the steel-walled 2-m box. The data were acquired at a distance of 400-m from the APRF reactor. The measurements were performed by APRF, Bubble Technology Industries, the Defence Research Establishment Ottawa, Establishment Technique Central de l'Armement, and Harry Diamond Laboratory. Calculations were carried out by the Oak Ridge National Laboratory and Science Applications International Corporation. The purpose of these experiments was to measure the neutron and gamma-ray dose as a function of detector location on the phantom for cases when the phantom was standing in the free-field and inside of the box. Neutron measurements were made using a BD-IOOR bubble detector and gamma-ray measurements were made using thermoluminescent detectors (TLD). Calculated and measured data were compared in terms of the C/M ratio. DNA mandated that C/M values of {plus minus}20% define the acceptable limits for the comparison of the dose and reduction factor data and for qualifying the MASH code in replicating integral parameters.

  5. DNA Radiation Environments Program Spring 1991 2-meter box experiments and analyses

    Energy Technology Data Exchange (ETDEWEB)

    Santoro, R.T. [Oak Ridge National Lab., TN (United States); Whitaker, S.Y. [Clark Atlanta Univ., GA (United States)

    1993-03-01

    This report summarizes the Spring 1991 2-m Box experiments that were performed at the Army Pulse Radiation Facility (APRF) at Aberdeen Proving Ground. These studies were sponsored by the Defense Nuclear Agency (DNA) under the Radiation Environments Program to obtain measured data for benchmarking the Adjoint Monte Carlo Code System, MASH, Version 1.0. The MASH code system was developed for the Department of Defense and NATO for calculating neutron and gamma-ray radiation fields and shielding protection factors for armored vehicles and military structures against nuclear weapon radiation. In the 2-m Box experiments, neutron and gamma-ray dose rates and reduction factors were measured in the free-field and as a function of position on an anthropomorphic phantom that was placed outside and inside a borated polyethylene lined steel-walled 2-m box. The data were acquired at a distance of 400-m from the APRF reactor. The purpose of these experiments was to measure the neutron and gamma-ray dose rates as a function of detector location on the phantom for cases when the phantom was in the free-field and inside of the box. Neutron measurements were made using a BD-100R bubble detector and gamma-ray measurements were made using thermoluminescent detectors (TLD). Calculated and measured data were compared in terms of the C/M ratio. The calculated and measured neutron and gamma-ray dose rates and reduction factors agreed on the average within the {plus_minus}20% limits mandated by DNA and demonstrate the capability of the MASH code system in reproducing measured data in nominally shielded assemblies.

  6. DNA Radiation Environments Program Spring 1991 2-meter box experiments and analyses. [DEfense Nuclear Agency (DNA)

    Energy Technology Data Exchange (ETDEWEB)

    Santoro, R.T. (Oak Ridge National Lab., TN (United States)); Whitaker, S.Y. (Clark Atlanta Univ., GA (United States))

    1993-03-01

    This report summarizes the Spring 1991 2-m Box experiments that were performed at the Army Pulse Radiation Facility (APRF) at Aberdeen Proving Ground. These studies were sponsored by the Defense Nuclear Agency (DNA) under the Radiation Environments Program to obtain measured data for benchmarking the Adjoint Monte Carlo Code System, MASH, Version 1.0. The MASH code system was developed for the Department of Defense and NATO for calculating neutron and gamma-ray radiation fields and shielding protection factors for armored vehicles and military structures against nuclear weapon radiation. In the 2-m Box experiments, neutron and gamma-ray dose rates and reduction factors were measured in the free-field and as a function of position on an anthropomorphic phantom that was placed outside and inside a borated polyethylene lined steel-walled 2-m box. The data were acquired at a distance of 400-m from the APRF reactor. The purpose of these experiments was to measure the neutron and gamma-ray dose rates as a function of detector location on the phantom for cases when the phantom was in the free-field and inside of the box. Neutron measurements were made using a BD-100R bubble detector and gamma-ray measurements were made using thermoluminescent detectors (TLD). Calculated and measured data were compared in terms of the C/M ratio. The calculated and measured neutron and gamma-ray dose rates and reduction factors agreed on the average within the [plus minus]20% limits mandated by DNA and demonstrate the capability of the MASH code system in reproducing measured data in nominally shielded assemblies.

  7. DNA Radiation Environments Program - Spring 1990 2-meter box experiments and analyses

    Energy Technology Data Exchange (ETDEWEB)

    Santoro, R.T [Oak Ridge National Lab., TN (United States); Whitaker, S.Y. [Clark Atlanta Univ., GA (United States)

    1992-09-01

    This report summarizes the Spring 1990 2-m Box Experiments performed at the Army Pulse Radiation Facility (APRF) at Aberdeen Proving Ground, Maryland. These studies were sponsored by the Defense Nuclear Agency (DNA) under the Radiation Environments Program to obtain measured data for benchmarking the Adjoint Monte Carlo Code System, MASH, Version 1.0. MASH was developed as the Department of Defense and NATO code system for calculating neutron and gamma-ray radiation fields and shielding protection factors for armored vehicles and military structures against nuclear weapon radiation. In the experiments, neutron and gamma-ray dose and reduction factors were measured in the free-field and as a function of position on an anthropomorphic phantom that was placed outside and inside the steel-walled 2-m box. The data were acquired at a distance of 400-m from the APRF reactor. The measurements were performed by APRF, Bubble Technology Industries, the Defence Research Establishment Ottawa, Establishment Technique Central de l`Armement, and Harry Diamond Laboratory. Calculations were carried out by the Oak Ridge National Laboratory and Science Applications International Corporation. The purpose of these experiments was to measure the neutron and gamma-ray dose as a function of detector location on the phantom for cases when the phantom was standing in the free-field and inside of the box. Neutron measurements were made using a BD-IOOR bubble detector and gamma-ray measurements were made using thermoluminescent detectors (TLD). Calculated and measured data were compared in terms of the C/M ratio. DNA mandated that C/M values of {plus_minus}20% define the acceptable limits for the comparison of the dose and reduction factor data and for qualifying the MASH code in replicating integral parameters.

  8. Film type SO-168 radiation study

    Science.gov (United States)

    Pierce, W. N.

    1972-01-01

    Investigations were performed to determine optimum exposure and processing procedures necessary to partially offset the effect of radiation to which film type SO-168 will be exposed during the Skylab Mission. This task became necessary when it was determined that original predictions of 2 to 3 RADS of radiation to which the film will be exposed were too low, and that levels as high as 3.5 to 4.0 RADS may be incurred, thus reducing image quality below an acceptable level. Tests results show that forced processing of type SO-168 film tended to reduce the density range to an unusable level, and that processing to a lower ASA value would provide greater image quality for the user.

  9. The effect of housing condition on the performance of two types of activity meters to detect estrus in dairy cows.

    Science.gov (United States)

    Roelofs, J B; Krijnen, C; van Erp-van der Kooij, E

    2017-04-15

    When the daily routine of a cow is disturbed, it may have a detrimental effect on the performance of activity meters to detect estrus. It is possible that during the pasture period, the daily routine of cows is disturbed, adversely affecting the performance of activity meters to detect estrus which does not happen when the cows are housed indoors. The objective of this study was to investigate whether housing conditions (pasture or indoor) affected the performance of activity meters to detect estrus in dairy cows. In this research, two types of activity meters were used, an activity meter attached to the leg and one mounted on the neck. Cows of two different herds were equipped with the Smarttag Leg and the Smarttag Neck (Nedap livestock management, Groenlo, the Netherlands). The study began during the pasture period (September) and ended during the indoor period (January). The pasture period ended at the beginning of November. So, about two months of pasture period and two months of indoor period were studied. Milk samples were collected twice a week during the morning milking and true estrus was determined by milk progesterone concentrations. In total, the dataset consisted of 95 true estrous periods and 1992 true non-estrous days of 56 cows for the pasture period and 138 true estrous periods and 3164 true non-estrous days of 65 cows for the indoor period. Overall, no differences in sensitivity, positive predictive value (PPV) and specificity were found between the pasture and indoor period for both types of sensors. There was also no difference in the performance between leg and neck activity meters. Sensitivity was between 76 and 82%, PPV was between 87 and 92% and specificity was between 99 and 100%. In conclusion, the sensitivity, PPV and specificity did not differ between the pasture and indoor period. This means that, in our study, the performance of both types of activity meters to detect estrus is not affected by housing conditions. Copyright © 2017

  10. Dynamic tests during cow milking with different types of milk meters.

    Science.gov (United States)

    Amirante, P; Bianchi, P; Montel, G L

    2005-01-01

    This study is related to the POM - Measure 2 - Project B15 'Veterinary services computerization and technical support to livestock farms', in which innovative plants solutions has been introduced to recognize the single animal to measure the quantity of produced milk, to centralize and automate the management, in different cow and sheep and goats breedings in Puglia and Basilicata regions. The experimentation has foreseen dynamic tests, during the real milking of the cows, in an apulian plant in which different measurers of the quantity of milk have been installed: weigh jar, electronic weighing 'bascule' milk-meter, electronic proportional milk-meter. In a mechanical point of view, the vacuum level and the vacuum fluctuations in three different milk pipe sections have been valued: at short milk tube, downstream from the claw, prior to the milk meter. Comparing the results, authors deduced that the electronic milkmeters, like the electronic proportional milk meter, allows inferior vacuum degree variations and less mechanical solicitations in cow udder; such situation is particularly evident with higher milk flow. The study also underlines that the vacuum drops during milking can be very critical if not immediately compensate with a suitable planning and periodic revision of the plants.

  11. IEEE Committee on Man and Radiation--COMAR technical information statement radiofrequency safety and utility Smart Meters.

    Science.gov (United States)

    Bushberg, Jerrold T; Foster, Kenneth R; Hatfield, James B; Thansandote, Arthur; Tell, Richard A

    2015-03-01

    This Technical Information Statement describes Smart Meter technology as used with modern electric power metering systems and focuses on the radio frequency (RF) emissions associated with their operation relative to human RF exposure limits. Smart Meters typically employ low power (-1 W or less) transmitters that wirelessly send electric energy usage data to the utility company several times per day in the form of brief, pulsed emissions in the unlicensed frequency bands of 902-928 MHz and 2.4-2.48 GHz or on other nearby frequencies. Most Smart Meters operate as wireless mesh networks where each Smart Meter can communicate with other neighboring meters to relay data to a data collection point in the region. This communication process includes RF emissions from Smart Meters representing energy usage as well as the relaying of data from other meters and emissions associated with maintaining the meter's hierarchy within the wireless network. As a consequence, most Smart Meters emit RF pulses throughout the day, more at certain times and less at others. However, the duty cycle associated with all of these emissions is very small, typically less than 1%, and most of the time far less than 1%, meaning that most Smart Meters actually transmit RF fields for only a few minutes per day at most. The low peak power of Smart Meters and the very low duty cycles lead to the fact that accessible RF fields near Smart Meters are far below both U.S. and international RF safety limits whether judged on the basis of instantaneous peak power densities or time-averaged exposures. This conclusion holds for Smart Meters alone or installed in large banks of meters.

  12. Sagnac interferometer as a speed-meter-type, quantum-nondemolition gravitational-wave detector

    Science.gov (United States)

    Chen, Yanbei

    2003-06-01

    According to quantum measurement theory, “speed meters”—devices that measure the momentum, or speed, of free test masses—are immune to the standard quantum limit (SQL). It is shown that a Sagnac-interferometer gravitational-wave detector is a speed meter and therefore in principle it can beat the SQL by large amounts over a wide band of frequencies. It is shown, further, that, when one ignores optical losses, a signal-recycled Sagnac interferometer with Fabry-Perot arm cavities has precisely the same performance, for the same circulating light power, as the Michelson speed-meter interferometer recently invented and studied by Purdue and the author. The influence of optical losses is not studied, but it is plausible that they be fairly unimportant for the Sagnac interferometer, as for other speed meters. With squeezed vacuum (squeeze factor e-2R=0.1) injected into its dark port, the recycled Sagnac interferometer can beat the SQL by a factor (10)≃3 over the frequency band 10 Hz≲f≲150 Hz using the same circulating power Ic˜820 kW as is to be used by the (quantum limited) second-generation Advanced LIGO interferometers—if other noise sources are made sufficiently small. It is concluded that the Sagnac optical configuration, with signal recycling and squeezed-vacuum injection, is an attractive candidate for third-generation interferometric gravitational-wave detectors (LIGO-III and EURO).

  13. Tumor vascular disruption using various radiation types

    Directory of Open Access Journals (Sweden)

    JJ Bevelacqua

    2014-04-01

    Full Text Available The feasibility of disrupting a tumor’s vascular structure with various radiation types and radionuclides is investigated. Calculated absorbed dose profiles for photons and 4He ions suggest that low-energy beta-gamma and alpha emitting radionuclides can deposit sufficient absorbed dose to disrupt a tumor’s vascular structure while minimizing the dose outside the blood vessel. Candidate radionuclides uniformly distributed in microspheres are theoretically investigated with respect to their vascular disruption potential and to offer an alternative to 90Y microsphere therapy. Requisite activities of candidate low-energy beta-gamma and alpha emitting radionuclides to facilitate vascular disruption are calculated.

  14. Study on a New Type of Electric-controlled Engine Fuel Consumption Meter Based on Volume Method

    Directory of Open Access Journals (Sweden)

    Qing-Yong Zhang

    2014-04-01

    Full Text Available At present study on the testing methods and instruments for vehicles’ fuel consumption is still not perfect. It still can’t provide a rapid and accurate measuring method and instrument. A new type of fuel consumption meter structure is developed which used two small containers to relay to supply the engine and realizes oil consumption measuring by detecting the real- time liquid level in the containers. Photoelectric sensors and a chip microcomputer are used to realize transient detection. Its structure and principle are analyzed. The system of its hardware and software of the electric-controlling system are designed. Some key components are selected and the process of exhausting, starting and measuring are designed. Precision test of the system is performed, and the result shows the accuracy of the meter in the range of 800 ml is 0.1 %, which meets the requirements and the feasibility of the structure is verified. Finally the main influencing factors are analyzed.

  15. Technology for radiation efficiency measurement of high-power halogen tungsten lamp used in calibration of high-energy laser energy meter.

    Science.gov (United States)

    Wei, Ji Feng; Hu, Xiao Yang; Sun, Li Qun; Zhang, Kai; Chang, Yan

    2015-03-20

    The calibration method using a high-power halogen tungsten lamp as a calibration source has many advantages such as strong equivalence and high power, so it is very fit for the calibration of high-energy laser energy meters. However, high-power halogen tungsten lamps after power-off still reserve much residual energy and continually radiate energy, which is difficult to be measured. Two measuring systems were found to solve the problems. One system is composed of an integrating sphere and two optical spectrometers, which can accurately characterize the radiative spectra and power-time variation of the halogen tungsten lamp. This measuring system was then calibrated using a normal halogen tungsten lamp made of the same material as the high-power halogen tungsten lamp. In this way, the radiation efficiency of the halogen tungsten lamp after power-off can be quantitatively measured. In the other measuring system, a wide-spectrum power meter was installed far away from the halogen tungsten lamp; thus, the lamp can be regarded as a point light source. The radiation efficiency of residual energy from the halogen tungsten lamp was computed on the basis of geometrical relations. The results show that the halogen tungsten lamp's radiation efficiency was improved with power-on time but did not change under constant power-on time/energy. All the tested halogen tungsten lamps reached 89.3% of radiation efficiency at 50 s after power-on. After power-off, the residual energy in the halogen tungsten lamp gradually dropped to less than 10% of the initial radiation power, and the radiation efficiency changed with time. The final total radiation energy was decided by the halogen tungsten lamp's radiation efficiency, the radiation efficiency of residual energy, and the total power consumption. The measuring uncertainty of total radiation energy was 2.4% (here, the confidence factor is two).

  16. Cloud types and the tropical Earth radiation budget, revised

    Science.gov (United States)

    Dhuria, Harbans L.; Kyle, H. Lee

    1989-01-01

    Nimbus-7 cloud and Earth radiation budget data are compared in a study of the effects of clouds on the tropical radiation budget. The data consist of daily averages over fixed 500 sq km target areas, and the months of July 1979 and January 1980 were chosen to show the effect of seasonal changes. Six climate regions, consisting of 14 to 24 target areas each, were picked for intensive analysis because they exemplified the range in the tropical cloud/net radiation interactions. The normal analysis was to consider net radiation as the independent variable and examine how cloud cover, cloud type, albedo and emitted radiation varied with the net radiation. Two recurring themes keep repeating on a local, regional, and zonal basis: the net radiation is strongly influenced by the average cloud type and amount present, but most net radiation values could be produced by several combinations of cloud types and amount. The regions of highest net radiation (greater than 125 W/sq m) tend to have medium to heavy cloud cover. In these cases, thin medium altitude clouds predominate. Their cloud tops are normally too warm to be classified as cirrus by the Nimbus cloud algorithm. A common feature in the tropical oceans are large regions where the total regional cloud cover varies from 20 to 90 percent, but with little regional difference in the net radiation. The monsoon and rain areas are high net radiation regions.

  17. Clay-cement concrete diaphragm of the type "slurry wall" in the 100 meter high dam

    Directory of Open Access Journals (Sweden)

    Radzinskiy Aleksandr Vladimirovich

    Full Text Available In the article the authors estimate the possibility of building a high (100 m high stone dam with clay-cement concrete diaphragm. This diaphragm is used as an antifiltering element and it is made of secant piles method of clay-cement concrete (method of "slurry wall". This diaphragm should be constructed in several phases, in our example example in three stages. Numerical studies of the stress-strain state of such a dam show that considerable compressive stresses can appear in the diaphragm. These stresses can be significantly (3...4 times greater than the strength of clay-cement concrete in compression. However it should be taken into consideration that the diaphragm of such a high dam will be crimped by horizontal stresses, i.e. clay-cement concrete will operate in the triaxial compression. Under these conditions the strength of clay-cement concrete will be significantly higher, therefore, the diaphragm reliability might be provided with a margin. For this reason, the most important issue in the engineering of a high dam with such type of diaphragm is to select the required composition of clay-cement concrete. Increasing its strength by extension of the cement fraction could increase modulus of deformation. Therefore it could lead to compressive stress increase and the strength state degradation. Hydrostatic pressure generates the areas of tensile stresses in the clay-cement concrete diaphragm due to the arising bending deformation. It threatens the formation of cracks in the clay-cement concrete, especially in the nodes interface diaphragm queues. It is recommended to match the diaphragm queues using ferroconcrete galleries. This should ensure flexibility of deformation between the gallery and the diaphragm.

  18. Hourly Variation in the Flow Measurements in the Jesus Maria Watershed with the Cup-type Current Meter Method

    Directory of Open Access Journals (Sweden)

    José Pablo Bonilla Valverde

    2017-12-01

    Full Text Available Conducting punctual gauging measurements in Costa Rica constitutes a common practice for the evaluation of water resources for drinking water supply.  The country has a database composed of punctual measurements made in most of the rivers of Costa Rica with almost forty years of information. Within this database, a single data (punctual gauging is used to characterize the whole month in which it was gauged. In order to corroborate the validity of this characterization, punctual gauging was performed every hour to confirm that the hourly variation is minimal.  The hourly gauging was carried out during the flow measurement campaign in the Jesus Maria watershed conducted on April 9th and 10th, 2013.  The flow measurements were performed using cup-type current meter method according to the ISO 2537: 2007 standard.  One third of the measurements showed less than ±1% variation and more than three quarters were in the range of ±5% variation. In all cases, excluding the lower basin of the Jesus Maria River, variations in the measurements are less than 10% relative to the median.  It is concluded that the hour variation is relatively small, and therefore, the database is validated – for the months at the end of the dry season.  This experience should be repeated in the same basin at other times of the year and on other basins to ensure that the temporal variability do not represent large differences in the flow.

  19. An Improved Measurement Method for the Strength of Radiation of Reflective Beam in an Industrial Optical Sensor Based on Laser Displacement Meter

    Directory of Open Access Journals (Sweden)

    Youngchul Bae

    2016-05-01

    Full Text Available An optical sensor such as a laser range finder (LRF or laser displacement meter (LDM uses reflected and returned laser beam from a target. The optical sensor has been mainly used to measure the distance between a launch position and the target. However, optical sensor based LRF and LDM have numerous and various errors such as statistical errors, drift errors, cyclic errors, alignment errors and slope errors. Among these errors, an alignment error that contains measurement error for the strength of radiation of returned laser beam from the target is the most serious error in industrial optical sensors. It is caused by the dependence of the measurement offset upon the strength of radiation of returned beam incident upon the focusing lens from the target. In this paper, in order to solve these problems, we propose a novel method for the measurement of the output of direct current (DC voltage that is proportional to the strength of radiation of returned laser beam in the received avalanche photo diode (APD circuit. We implemented a measuring circuit that is able to provide an exact measurement of reflected laser beam. By using the proposed method, we can measure the intensity or strength of radiation of laser beam in real time and with a high degree of precision.

  20. Cloud types and the tropical earth radiation budget

    Science.gov (United States)

    Dhuria, Harbans L.; Kyle, H. Lee

    1990-01-01

    Nimbus-7 cloud and earth radiation budget data are compared in a study of the effects of clouds on the tropical radiation budget. The data consist of daily averages over fixed 500 sq km target areas, and the months of July 1979 and January 1980 were chosen to show the effect of seasonal changes. Six climate regions, consisting of 14 to 24 target areas each, were picked for intensive analysis because they exemplified the range in the tropical cloud/net radiation interactions. It is found that the net radiation is strongly influenced by the average cloud type and amount present, but most net radiation values could be produced by several combinations of cloud types and amount. The regions of highest net radiation (greater than 125 W/sq m) tend to have medium to heavy cloud cover. In these cases, thin medium-altitude clouds predominate. Their cloud tops are normally too warm to be classified as cirrus by the Nimbus cloud algorithm. In the tropical oceans there are large regions where the total regional cloud cover varies from 20 to 90 percent, but with little regional difference in the net radiation. The monsoon and rain areas are high net radiation regions.

  1. Types of radiation mass casualties and their management.

    Science.gov (United States)

    Jaworska, Alicja

    2009-01-01

    Management of radiation mass casualty exposure that may occur as a result of nuclear or radiation accident will depend on the type of accident, and of the knowledge about the actual radiation exposure situation for those who might be involved. Management of the public after an accident in a nuclear or radiation installation will follow existing specific emergency plans, and will take advantage of existing radiation monitoring systems. In other radiation mass casualty exposures, whenever accidental or malevolent use of radiation, there will be a requirement to employ screening programs for indentifying and sorting out exposed people (radiological triage), who will need medical treatment and/or other assistance like decontamination and individual dose assessment. In the later stage after the accident the monitoring for dose assessment purposes for those who will need medical or public health assistance will be required. Demand for dose assessment for large groups of individuals may create the need for international assistance. Prompt and credible public information is vital in all radiation emergencies, and it would be even more important in situations when radiation mass casualties result from exposures to nuclear or radiological material out of regulatory control. In such situations unpredictability of the event creates increase in the risk perception and public communication activities of the authorities will be the key element to prevent unnecessary fear and panic, and the measure to reassure the populace.

  2. Sound radiation characteristics of a box-type structure

    Science.gov (United States)

    Ran Lin, Tian; Pan, Jie

    2009-09-01

    The finite element and boundary element methods are employed in this study to investigate the sound radiation characteristics of a box-type structure. It has been shown [T.R. Lin, J. Pan, Vibration characteristics of a box-type structure, Journal of Vibration and Acoustics, Transactions of ASME 131 (2009) 031004-1-031004-9] that modes of natural vibration of a box-type structure can be classified into six groups according to the symmetry properties of the three panel pairs forming the box. In this paper, we demonstrate that such properties also reveal information about sound radiation effectiveness of each group of modes. The changes of radiation efficiencies and directivity patterns with the wavenumber ratio (the ratio between the acoustic and the plate bending wavenumbers) are examined for typical modes from each group. Similar characteristics of modal radiation efficiencies between a box structure and a corresponding simply supported panel are observed. The change of sound radiation patterns as a function of the wavenumber ratio is also illustrated. It is found that the sound radiation directivity of each box mode can be correlated to that of elementary sound sources (monopole, dipole, etc.) at frequencies well below the critical frequency of the plates of the box. The sound radiation pattern on the box surface also closely related to the vibration amplitude distribution of the box structure at frequencies above the critical frequency. In the medium frequency range, the radiated sound field is dominated by the edge vibration pattern of the box. The radiation efficiency of all box modes reaches a peak at frequencies above the critical frequency, and gradually approaches unity at higher frequencies.

  3. Radiation effects on science instruments in Grand Tour type missions

    Science.gov (United States)

    Parker, R. H.

    1972-01-01

    The extent of the radiation effects problem is delineated, along with the status of protective designs for 15 representative science instruments. Designs for protecting science instruments from radiation damage is discussed for the various instruments to be employed in the Grand Tour type missions. A literature search effort was undertaken to collect science instrument components damage/interference effects data on the various sensitive components such as Si detectors, vidicon tubes, etc. A small experimental effort is underway to provide verification of the radiation effects predictions.

  4. Comparison of air kerma area product and air kerma meter calibrations for X-ray radiation qualities used in diagnostic radiology

    Science.gov (United States)

    Hourdakis, C. J.; Csete, I.; Daures, J.; Jarvinen, H.; Mihailescu, L.-C.; Sochor, V.; Novak, L.; Pedersen, M.; Kosunen, A.; Toroi, P.; Denoziere, M.; Büermann, L.; Megzifene, A.; Einarsson, G.; Ferrari, P.; dePooter, J.; Bjerke, H.; Brodecki, M.; Cardoso, J.; Bercea, S.; Ciraj-Bjelac, O.; Compel, J.; Glavič-Cindro, D.; Ginjaume, M.; Persson, L.; Grindborg, J.-E.

    2015-01-01

    The EURAMET #1177 project, identified as EURAMET RI(I) - S9 comparison, was the first EURAMET wide scale supplementary comparison in the field of diagnostic radiology for air kerma area product, PKA, and air kerma, K. It was conducted with the goal of testing the measurement and calibration capabilities for PKA and K, as well as of supporting the relevant CMCs of the participating laboratories. Two commercial KAP meters and an ionization chamber were selected as transfer instruments and circulated between the 22 European participants. The measurements were performed from April 2011 until July 2012. The stability and the performance of the transfer instruments were tested by the pilot laboratory (IRCL/GAEC-EIM) and few other laboratories as well. The test results revealed that the energy (radiation quality), Q, irradiation area, A, and air kerma rate, dot K dependences of response of the transfer KAP meters influence the comparison of the results when different measurement conditions were pertained and therefore, appropriate correction factors were obtained and applied to the reported calibration results of the laboratories, when necessary. The comparison reference values (CRVs) for each instrument were determined as the weighted mean of the calibration coefficients of the three participating primary laboratories. The relative standard uncertainty of the CRVs were in the range of (0.4 - 1.6)% depending on the transfer instruments and beam qualities. The comparison result as the ratio of the corrected calibration coefficient of participant and the respective CRV, and its uncertainty were calculated for all beam qualities and transfer instruments. The informative degrees of equivalence (DoE) were calculated for the refrence RQR 5 beam quality. In case of air kema area product measurements the results for the RADCAL PDC KAP meter were used. The 216 KAP meter calibration results of the two different transfer instruments in terms of air kerma area product were consistent

  5. Treatment of radiation nephropathy with ACE inhibitors and AII type-1 and type-2 receptor antagonists.

    Science.gov (United States)

    Moulder, J E; Fish, B L; Cohen, E P

    2007-01-01

    Radiation nephropathy has emerged as a significant complication of bone marrow transplantation and radionuclide radiotherapy, and is a potential sequela of radiological terrorism and radiation accidents. In the early 1990's, it was demonstrated that experimental radiation nephropathy could be treated with a thiol-containing ACE inhibitor, captopril. Further studies have shown that enalapril (a non-thiol ACE inhibitor) is also effective in the treatment of experimental radiation nephropathy, as are both AII type-1 (AT(1)) and type-2 (AT(2)) receptor antagonists. ACE inhibitors and AII receptor antagonists are also effective in the mitigation (prevention) of radiation nephropathy. Other types of antihypertensive drugs are ineffective in mitigation, but brief use of a high-salt diet in the immediate post-irradiation period significantly decreases renal injury. There are differences between mitigation and treatment of radiation nephropathy that imply that different mechanisms are operating. First, a high-salt diet is effective in the mitigation of radiation nephropathy, but deleterious on the treatment of established disease. Second, AT(1) blockade is more effective than ACE inhibition for mitigation of radiation nephropathy, but equally effective for treatment. Third, the efficacy of AT(1) blockade and ACE inhibition is highly dependent on drug dose in mitigation of radiation nephropathy, but not so in treatment. Finally, while AT(2) blockade augments the benefit of AT(1) blockade in mitigation of radiation nephropathy, it does not do so in treatment. We hypothesize that while mitigation of radiation nephropathy works by suppression of the renin-angiotensin system, treatment of established radiation nephropathy requires blood pressure control in addition to (or possibly instead of) suppression of the renin-angiotensin system.

  6. Improved cavity-type absolute total-radiation radiometer

    Science.gov (United States)

    Kendall, J. M., Sr.; Plamondon, J. A., Jr.

    1967-01-01

    Conical cavity-type absolute radiometer measures the intensity of radiant energy to an accuracy of one to two percent in a vacuum of ten to the minus fifth torr or lower. There is a uniform response over the ultraviolet, visible, and infrared range, and it requires no calibration or comparison with a radiation standard.

  7. Auroral kilometric radiation triggered by type II solar radio bursts

    Science.gov (United States)

    Calvert, W.

    1985-01-01

    The previously-reported triggering of auroral kilometric radiation (AKR) during type III solar radio bursts was attributed to the incoming radio waves rather than other aspects of the burst's causative solar flare. This conclusion has now been confirmed by ISEE-1 and ISEE-3 observations showing AKR which seems to have been triggered also by a subsequent type II solar radio burst, up to eleven hours after the flare.

  8. Calibration of reference KAP-meters at SSDL and cross calibration of clinical KAP-meters.

    Science.gov (United States)

    Hetland, Per O; Friberg, Eva G; Ovrebø, Kirsti M; Bjerke, Hans H

    2009-01-01

    In the summer of 2007 the secondary standard dosimetry laboratory (SSDL) in Norway established a calibration service for reference air-kerma product meter (KAP-meter). The air-kerma area product, P(KA), is a dosimetric quantity that can be directly related to the patient dose and used for risk assessment associated with different x-ray examinations. The calibration of reference KAP-meters at the SSDL gives important information on parameters influencing the calibration factor for different types of KAP-meters. The use of reference KAP-meters calibrated at the SSDL is an easy and reliable way to calibrate or verify the P(KA) indicated by the x-ray equipment out in the clinics. Twelve KAP-meters were calibrated at the SSDL by use of the substitution method at five diagnostic radiation qualities (RQRs). The calibration factors varied from 0.94 to 1.18. The energy response of the individual KAP-meters varied by a total of 20% between the different RQRs and the typical chamber transmission factors ranged from 0.78 to 0.91. It is important to use a calibrated reference KAP-meter and a harmonised calibration method in the P(KA) calibration in hospitals. The obtained uncertainty in the P(KA) readings is comparable with other calibration methods if the information in the calibration certificate is correct used, corrections are made and proper positioning of the KAP-chamber is performed. This will ensure a reliable estimate of the patient dose and a proper optimisation of conventional x-ray examinations and interventional procedures.

  9. Critical ingredients of Type Ia supernova radiative-transfer modelling

    Science.gov (United States)

    Dessart, Luc; Hillier, D. John; Blondin, Stéphane; Khokhlov, Alexei

    2014-07-01

    We explore the physics of Type Ia supernova (SN Ia) light curves and spectra using the 1D non-local thermodynamic equilibrium (non-LTE) time-dependent radiative-transfer code CMFGEN. Rather than adjusting ejecta properties to match observations, we select as input one `standard' 1D Chandrasekhar-mass delayed-detonation hydrodynamical model, and then explore the sensitivity of radiation and gas properties of the ejecta on radiative-transfer modelling assumptions. The correct computation of SN Ia radiation is not exclusively a solution to an `opacity problem', characterized by the treatment of a large number of lines. We demonstrate that the key is to identify and treat important atomic processes consistently. This is not limited to treating line blanketing in non-LTE. We show that including forbidden-line transitions of metals, and in particular Co, is increasingly important for the temperature and ionization of the gas beyond maximum light. Non-thermal ionization and excitation are also critical since they affect the colour evolution and the ΔM15 decline rate of our model. While impacting little the bolometric luminosity, a more complete treatment of decay routes leads to enhanced line blanketing, e.g. associated with 48Ti in the U and B bands. Overall, we find that SN Ia radiation properties are influenced in a complicated way by the atomic data we employ, so that obtaining converged results is a real challenge. Nonetheless, with our fully fledged CMFGEN model, we obtain good agreement with the golden standard Type Ia SN 2005cf in the optical and near-IR, from 5 to 60 d after explosion, suggesting that assuming spherical symmetry is not detrimental to SN Ia radiative-transfer modelling at these times. Multi-D effects no doubt matter, but they are perhaps less important than accurately treating the non-LTE processes that are crucial to obtain reliable temperature and ionization structures.

  10. Radiation stability of fluorite-type nuclear oxides

    Energy Technology Data Exchange (ETDEWEB)

    Garrido, Frederico [Centre de Spectrometrie Nucleaire et de Spectrometrie de Masse, CNRS-IN2P3-Universite Paris-Sud, Batiments 104-108, 91405 Orsay Campus (France)], E-mail: Frederico.Garrido@csnsm.in2p3.fr; Vincent, Laetitia [Centre de Spectrometrie Nucleaire et de Spectrometrie de Masse, CNRS-IN2P3-Universite Paris-Sud, Batiments 104-108, 91405 Orsay Campus (France); Nowicki, Lech [Andrzej Soltan Institute for Nuclear Studies, Hoza 69, 00-681 Warsaw (Poland); Sattonnay, Gael [Laboratoire d' Etudes des Materiaux Hors-Equilibre, Institut de Chimie Moleculaire et des Materiaux d' Orsay, UMR 8182, Universite Paris-Sud, Batiment 410, 91405 Orsay Cedex (France); Thome, Lionel [Centre de Spectrometrie Nucleaire et de Spectrometrie de Masse, CNRS-IN2P3-Universite Paris-Sud, Batiments 104-108, 91405 Orsay Campus (France)

    2008-06-15

    Oxides with the fluorite-type structure are radiation tolerant materials. They are widely used or envisaged in hostile nuclear environments, such as nuclear fuels or inert transmutation matrices for actinide burning. Study of the radiation stability of this class of solids in various radiative fields is of major importance. Two issues which may affect the stability of materials are considered in this work: the production of radiation damage (ballistic contribution); the modification of the matrix composition by doping (chemical contribution). Both contributions may drastically affect the solid stability. Urania and zirconia single crystals were chosen as fluorite-type canonical systems. They were implanted with low-energy inert gases (He or Xe). The damage in-growth, due to both ballistic and chemical contributions, was investigated by in situ RBS/C experiments in the channelling mode and TEM. Two main steps in the disordering kinetics were observed for both inert gases. Relevant key parameters were found to be: the number of displaced lattice atoms created by the slowing-down of energetic ions during the implantation process; the concentration of noble gas atoms in the solid which cause the formation of large stress fields surrounding gas aggregates.

  11. The Dielectric Bolometer, A New Type of Thermal Radiation Detector

    Science.gov (United States)

    Hanel, R. A.

    1960-01-01

    Thermal detectors for the infrared, such as thermocouples and bolometers, are limited in their ultimate sensitivity predominantly by Johnson noise rather than temperature noise. Low noise figures are hard to achieve since Johnson noise preponderates temperature noise, which is the only essential noise for thermal detectors. The dielectric constants of some materials are sufficiently temperature dependent to make a new type of bolometer feasible. The basic theory of a dielectric bolometer, as shown here, promises noise figures below 3 decibels even at chopper frequencies well above the 1/tau value of the detector. Ferroelectrics such as barium-strontium titanate and others seem to be well suited for radiation-cooled dielectric bolometers.

  12. Your Glucose Meter

    Science.gov (United States)

    ... by Audience For Women Women's Health Topics Your Glucose Meter Share Tweet Linkedin Pin it More sharing ... Your Blood Sugar and Caring for Your Meter Glucose meters test and record how much sugar (called ...

  13. Fundamental and harmonic radiation in type III solar radio bursts

    Science.gov (United States)

    Robinson, P. A.; Cairns, I. H.

    1994-01-01

    Type III solar radio bursts are investigated by modeling the propagation of the electron beam and the generation and subsequent propagation of waves to the observer. Predictions from this model are compared in detail with particle, Langmuir wave, and radio data from the International Sun Earth Explorer-3 (ISSE-3) spacecraft and with other observations to clarify the roles of fundamental and harmonic emission in type III radio bursts. Langmuir waves are seen only after the arrival of the beam, in accord with the standard theory. These waves persist after a positive beam slope is last resolved, implying that sporadic positive slopes persist for some time, unresolved but in accord with the predictions of stochastic growth theory. Local electromagnetic emission sets in only after Langmuir waves are seen, in accord with the standard theory, which relies on nonlinear processes involving Langmuir waves. In the events investigated here, fundamental radiation appears to dominate early in the event, followed and/or accompanied by harmonic radiation after the peak, with a long-lived tail of multiply scattered fundamental or harmonic emission extending long afterwards. These results are largely independent of, but generally consistent with, the conclusions of earlier works.

  14. Instrument evaluation no. 16. Nuclear enterprises portable doserate meter type PDR4 and external probes types BP1/1, BP8 and GP9

    CERN Document Server

    Burgess, P H

    1979-01-01

    The various radiations encountered in radiological protection cover a wide range of energies and radiation measurements have to be carried out under an equally broad spectrum of environmental conditions. This report is one of a series intended to give information on the performance characteristics of radiological protection instruments, to assist in the selection of appropriate instruments for a given purpose, to interpret the results obtained with such instruments, and, in particular, to know the likely sources and magnitude of errors that might be associated with measurements in the field. The radiation, electrical and environmental characteristics of radiation protection instruments are considered together with those aspects of the construction which make an instrument convenient for routine use. To provide consistent criteria for instrument performance, the range of tests performed on any particular class of instrument, the test methods and the criteria of acceptable performance are based broadly on the a...

  15. Radiation Hydrodynamical Models for Type I Superluminous Supernovae

    Science.gov (United States)

    Nomoto, Ken'ichi; Sorokina, Elena; Blinnikov, Sergei; Tolstov, Alexey; Bersten, Melina; Quimby, Robert

    The physical origin of Type I superluminous supernovae (SLSNe-I), whose luminosities are 10 to 100 times brighter than normal core-collapse supernovae, remains still unknown. Radioactive-decays, magnetars, and circumstellar interactions have been proposed for the power source the light curves, although no definitive conclusions have been reached yet. Since most of light curve studies have been based on simplified semi-analytic models, we have constructed detailed light curve models for various mass of stars including very massive ones and large amount of mass loss with radiation hydrodynamical calculations. Here we focus on the magnetar and circumstellar interaction models and compare their rising time, peak luminosity, width, decline rate of the light curves with observations which show quite a large diversities. We then discuss how to discriminate these models, relevant models parameters, their evolutionary origins, possible roles of chemical enrichment of the early universe, and implications for the identifications of first stars.

  16. What to Know about Brachytherapy (A Type of Internal Radiation Therapy)

    Science.gov (United States)

    N ational C ancer I nstitute Understanding Radiation Therapy What To Know About Brachytherapy (A Type of Internal Radiation Therapy) “I asked questions. My doctor took the time to help my family ...

  17. Repetitive nanosecond electron accelerators type URT-1 for radiation technology

    Science.gov (United States)

    Sokovnin, S. Yu.; Balezin, M. E.

    2018-03-01

    The electron accelerator URT-1М-300 for mobile installation was created for radiation disinfecting to correct drawbacks that were found the URT-1M electron accelerator operation (the accelerating voltage up to 1 МV, repetition rate up to 300 pps, electron beam size 400 × 100 mm, the pulse width about 100 ns). Accelerator configuration was changed that allowed to reduce significantly by 20% tank volume with oil where is placed the system of formation high-voltage pulses, thus the average power of the accelerator is increased by 6 times at the expense of increase in pulses repetition rate. Was created the system of the computerized monitoring parameters (output parameters and thermal mode) and remote control of the accelerator (charge voltage, pulse repetition rate), its elements and auxiliary systems (heat of the thyratron, vacuum system), the remote control panel is connected to the installation by the fiber-optical channel, what lightens the work for service personnel. For generating an electron beam up to 400 mm wide there are used metal- ceramic] and metal-dielectric cold cathodes of several emission elements (plates) with a non-uniform distribution of the electron beam current density on the output foil ± 15%. It was found that emission drop of both type of cathodes, during the operation at the high repetition rate (100 pps) is substantial at the beginning of the process, and then proceeds rather slowly that allows for continuous operation up to 40 h. Experiments showed that linear dependence of the voltage and a signal from the pin-diode remains within the range of the charge voltage 45-65 kV. Thus, voltage increases from 690 to 950 kV, and the signal from the pin-diode - from (2,8-4,6)*104 Gy/s. It allows to select electron energy quite precisely with consideration of the radiation technology requirements.

  18. Decameter storm radiation. II. [type 3 burst observations

    Science.gov (United States)

    Gergely, T. E.; Kundu, M. R.

    1975-01-01

    The height, size, directivity, and lifetime of decametric storm sources are investigated. The height of the continuum sources is determined from the rotation rate, and the gradient of electron density for the regions of storm origin is computed by assuming that the radiation originates at the plasma frequency. The mean angular size of the sources is found to be quite large (increasing with decreasing frequency), the storm continuum is strongly directive toward the disk center, and east-west asymmetry is observed at decameter wavelengths. Two distinct classes of type III bursts are observed during storms: 'off-fringe' (displaced in position from the continuum source) and 'on-fringe' (coinciding in position with the continuum). A model of the storm region is proposed in which the 'on-fringe' bursts originate in regions of diverging field lines above closed magnetic loops and the 'off-fringe' bursts are excited by energetic electron streams having access to open field lines at the base of the loops.

  19. Design and construction of portable survey meter

    Science.gov (United States)

    Singseeta, W.; Thong-aram, D.; Pencharee, S.

    2017-09-01

    This work was aimed to design and construction of portable survey meter for radiation dose measuring. The designed system consists of 4 main parts consisting of low voltage power supply, radiation detection, radiation measurement and data display part on android phone. The test results show that the ripple voltage of low voltage power supply is less than 1%, the maximum integral counts are found to be 104 counts per second and the maximum distance of wireless commination between the server and the client is about 10 meter. It was found that the developed system had small size and light weight for portable instrument.

  20. Electromagnetic radiation from vortex flow in Type-II superconductors.

    Science.gov (United States)

    Bulaevskii, L N; Chudnovsky, E M

    2006-11-10

    We show that a moving vortex lattice, as it comes to a crystal edge, radiates into a free space the harmonics of the washboard frequency, omega(0)=2pi v/a, up to a superconducting gap, Delta/variant Planck's over 2pi. Here v is the velocity of the vortex lattice and a is the intervortex spacing. We compute radiation power and show that this effect can be used for the generation of terahertz radiation and for characterization of moving vortex lattices.

  1. Radiation in controlled environments: influence of lamp type and filter material

    Science.gov (United States)

    Bubenheim, D. L.; Bugbee, B.; Salisbury, F. B.

    1988-01-01

    Radiation in controlled environments was characterized using fluorescent and various high-intensity-discharge (HID) lamps, including metal halide, low-pressure sodium, and high-pressure sodium as the radiation source. The effects of water, glass, or Plexiglas filters on radiation were determined. Photosynthetic photon flux (PPF, 400 to 700 nm), spectra (400 to 1000 nm), shortwave radiation (285-2800 nm), and total radiation (300 to 100,000 nm) were measured, and photosynthetically active radiation (PAR, 400 to 700 nm) and longwave radiation (2800 to 100,000 nm) were calculated. Measurement of PPF alone was not an adequate characterization of the radiation environment. Total radiant flux varied among lamp types at equal PPF. HID lamps provided a lower percentage of longwave radiation than fluorescent lamps, but, when HID lamps provided PPF levels greater than that possible with fluorescent lamps, the amount of longwave radiation was high. Water was the most effective longwave radiation filter. Glass and Plexiglas similarly filtered longwave more than shortwave radiation, but transmission of nonphotosynthetic shortwave radiation was less with Plexiglas than glass. The filter materials tested would not be expected to influence photomorphogenesis because radiation in the action spectrum of phytochrome was not altered, but this may not be the only pigment involved.

  2. Estimation of background radiation at Rivers State University of ...

    African Journals Online (AJOL)

    Background radiation from the use of photocopies, computers and other electronic devices around River State University of Science and Technology was measured using a specialize digital, radiation meter type, radalert - 50, which is optimized to detect radiations like alpha, beta, gamma and x-rays. Measurements were ...

  3. Influence of fracture type and surgeon experience on the emission of radiation in distal radius fractures.

    Science.gov (United States)

    Kraus, Michael; Röderer, Götz; Max, Melanie; Krischak, Gert; Gebhard, Florian; Riepl, Christoph

    2013-07-01

    Ionising radiation is a potential risk for potentially exposed personnel. Only a few studies have examined the factors contributing to the emission of radiation in orthopaedic trauma procedures. We hypothesize that the experience of the surgeon and the fracture type influence the emission of radiation intraoperatively. In a retrospective analysis, we examined 100 consecutive distal radius fractures receiving a volar plate osteosynthesis. The following parameters were documented: demographic data, plate system, fracture type, duration of the surgical procedure and duration of the emission of radiation, the experience level of the surgeon and the first assisting surgeon. Of all included patients (74 female), 48 had a type A, 7 a type B and 45 a type C fracture. The duration of radiation was longer for type C fractures [1.04 min (min)] in comparison to type A fractures (0.88 min) (P = 0.8152). In the type C subgroup, the highest amount of radiation was required for type C3 fractures (1.6 min), which was significantly more in comparison to type A (P = 0.0460) and type C1 fractures (P = 0.0089). The intraoperative emission of radiation (P = 0.00141) and the procedure time (P = 0.0006) depended on the experience of the surgical team. The emission of radiation during this procedure depends on the fracture type and the experience of the surgical team. Operating theatre personnel should be aware of the higher emission rates during the treatment of type C fractures and in teaching hospitals with inexperienced team members.

  4. A statistical study of solar type III bursts and auroral kilometric radiation onsets

    Science.gov (United States)

    Farrell, W. M.; Gurnett, D. A.

    1985-01-01

    Simultaneous occurrences of type III solar radio bursts and auroral kilometric radiation were observed by Calvert (1981) using ISEE 1 spectrograms. Calvert presented evidence suggesting that the incoming type III burst stimulates the onset of auroral kilometric radiation (AKR). This paper presents a statistical study of the correlation between type III bursts and auroral kilometric radiation. A superposed epoch analysis was performed on as many as 186 type III events. The type III bursts were detected by the ISEE 3 spacecraft on the sunward side of the earth. At the same time the IMP 8 spacecraft was used to detect onsets of kilometric radiation on the nightside of the earth. For each event the intensities measured by ISEE 3 (type III intensities) were subtracted from the intensities measured by IMP 8 (type III and possible AKR intensities). The resulting intensities for each event were then added to determine if kilometric radiation was preferentially observed following a type III burst. This analysis was performed at frequencies of 100, 178, and 500 kHz. The results of this study show that a statistically significant correlation exists between incoming type III bursts from the sun and kilometric radiation from the earth.

  5. Assessment of ambient dose equivalent rate performance of an automatic survey meter as an instrument to quantify the presence of radiation in soils

    CERN Document Server

    Yoshimura, E M; Okuno, E

    2002-01-01

    Those who work in radiation protection are faced with various quantities that were created to account for the effects of ionizing radiation in the human body. As far as the experimental point of view is concerned, each available equipment is planned to measure a distinct quantity, for a specific radiation protection application, and it is not always clear which one it is. This paper shows a series of tests, planned and applied to a portable gamma ray spectrometer, in order to assure that the monitoring low dose levels of radiation with it is reliable. The equipment is fully automated and does not allow modifications of the conversion factors from counts to ambient dose equivalent. It is therefore necessary to assure that the values provided by the equipment are correct and refer to the actual situation one expects to find in practice. The system is based on an NaI(Tl) scintillation detector, mounted with its electronics in a portable case, suitable for field measurements. It measures ambient dose equivalent r...

  6. Investigation of gamma-ray fingerprint identifying mechanism for the types of radiation sources

    CERN Document Server

    Liu Su Ping; Gu Dang Chang; Gong-Jian; Hao Fan Hua; Hu Guang Chun

    2002-01-01

    Radiation fingerprints sometimes can be used to label and identify the radiation resources. For instance, in a future nuclear reduction treaty that requires verification of irreversible dismantling of reduced nuclear warheads, the radiation fingerprints of nuclear warheads are expected to play a key role in labelling and identifying the reduced warheads. It would promote the development of nuclear warheads deep-cuts verification technologies if authors start right now some investigations on the issues related to the radiation fingerprints. The author dedicated to the investigation of gamma-ray fingerprint identifying mechanism for the types of radiation resources. The purpose of the identifying mechanism investigation is to find a credible way to tell whether any two gamma-ray spectral fingerprints that are under comparison are radiated from the same resource. The authors created the spectrum pattern comparison (SPC) to study the comparability of the two radiation fingerprints. Guided by the principle of SPC,...

  7. Quantifying Diurnal Cloud Radiative Effects by Cloud Type in the Tropical Western Pacific

    Energy Technology Data Exchange (ETDEWEB)

    Burleyson, Casey D.; Long, Charles N.; Comstock, Jennifer M.

    2015-06-01

    Cloud radiative effects are examined using long-term datasets collected at the three Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facilities in the tropical western Pacific. We quantify the surface radiation budget, cloud populations, and cloud radiative effects by partitioning the data by cloud type, time of day, and as a function of large scale modes of variability such as El Niño Southern Oscillation (ENSO) phase and wet/dry seasons at Darwin. The novel facet of our analysis is that we break aggregate cloud radiative effects down by cloud type across the diurnal cycle. The Nauru cloud populations and subsequently the surface radiation budget are strongly impacted by ENSO variability whereas the cloud populations over Manus only shift slightly in response to changes in ENSO phase. The Darwin site exhibits large seasonal monsoon related variations. We show that while deeper convective clouds have a strong conditional influence on the radiation reaching the surface, their limited frequency reduces their aggregate radiative impact. The largest source of shortwave cloud radiative effects at all three sites comes from low clouds. We use the observations to demonstrate that potential model biases in the amplitude of the diurnal cycle and mean cloud frequency would lead to larger errors in the surface energy budget compared to biases in the timing of the diurnal cycle of cloud frequency. Our results provide solid benchmarks to evaluate model simulations of cloud radiative effects in the tropics.

  8. Ultrasonic flow meter

    NARCIS (Netherlands)

    Lötters, Joost Conrad; Snijders, G.J.; Volker, A.W.F.

    2014-01-01

    The invention relates to an ultrasonic flow meter comprising a flow tube for the fluid whose flow rate is to be determined. The flow meter comprises a transmitting element for emitting ultrasonic waves, which is provided on the outer jacket of the flow tube. A receiving element, which is provided on

  9. Solitons and second harmonic radiation in type III bursts

    Science.gov (United States)

    Papadopoulos, K.; Freund, H. P.

    1978-01-01

    The emission at the second harmonic of the plasma frequency from self-consistent Langmuir solitons is calculated. The theory predicts, in a natural way, the observed transition from the region where the intensity is linearly proportional to the electron flux to the region where the radio intensity is proportional to the square of the electron flux. A detailed comparison of the radiation observed at the second harmonic for the burst of 18:10 UT March 31, 1976, with the one expected on the assumption of radiation from solitons, using the correlated in situ measurements of the electric fields at the second harmonic, and their spatial structure, provides strong evidence that, for the first time, Langmuir solitons have been observed in space.

  10. Environmental test results for the CDV-711 Mark III and Model 2 remote-sensor radiation meters. Technical report, May 1968-October 1969

    Energy Technology Data Exchange (ETDEWEB)

    Groeber, E.O.; Lake, G.H.

    1970-01-01

    The Air Force has a stated requirement for an instrument to monitor the gamma radiation associated with a fallout environment and to be used Air Force wide in fallout shelters and command posts. The Office of Civil Defense (OCD) has developed two instruments, the CDv-711 Mark III, that could possibly satisfy the stated requirement. Both the Model 2 and the Mark III were operationally and environmentally tested to see if one of the instruments was suitable for Air Force use, either with or without additional engineering development.

  11. AREA MONITORING OF AMBIENT DOSE RATES IN PARTS OF SOUTH-WESTERN NIGERIA USING A GPS-INTEGRATED RADIATION SURVEY METER.

    Science.gov (United States)

    Okeyode, I C; Rabiu, J A; Alatise, O O; Makinde, V; Akinboro, F G; Al-Azmi, D; Mustapha, A O

    2017-04-01

    A radiation monitoring system comprising a Geiger-Muller counter connected to a smart phone via Bluetooth was used for a dose rate survey in some parts of south-western Nigeria. The smart phone has the Geographical Positioning System, which provides the navigation information and saves it along with the dose rate data. A large number of data points was obtained that shows the dose rate distribution within the region. The results show that the ambient dose rates in the region range from 60 to 520 nSv -1 and showed a bias that is attributable to the influence of geology on the ambient radiation dose in the region. The geology influence was demonstrated by superimposing the dose rate plot and the geological map of the area. The potential applications of the device in determining baseline information and in area monitoring, e.g. for lost or abandoned sources, radioactive materials stockpiles, etc., were discussed in the article, particularly against the background of Nigeria's plan to develop its nuclear power program. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Ramp Metering Status in California

    Directory of Open Access Journals (Sweden)

    Zhongren Wang

    2013-12-01

    Full Text Available The purpose of this paper is to provide an update of the major improvement in terms of ramp metering design and operations in California. These updates include ramp metering policies, ramp metering development plans, ramp metering design manual, and ramp metering and system management initiatives.

  13. Peak flow meter (image)

    Science.gov (United States)

    A peak flow meter is commonly used by a person with asthma to measure the amount of air that can be ... become narrow or blocked due to asthma, peak flow values will drop because the person cannot blow ...

  14. Dependence of Early and Late Chromosomal Aberrations on Radiation Quality and Cell Types

    Science.gov (United States)

    Lu, Tao; Zhang, Ye; Krieger, Stephanie; Yeshitla, Samrawit; Goss, Rosalin; Bowler, Deborah; Kadhim, Munira; Wilson, Bobby; Rohde, Larry; Wu, Honglu

    2017-01-01

    Exposure to radiation induces different types of DNA damage, increases mutation and chromosome aberration rates, and increases cellular transformation in vitro and in vivo. The susceptibility of cells to radiation depends on genetic background and growth condition of cells, as well as types of radiation. Mammalian cells of different tissue types and with different genetic background are known to have different survival rate and different mutation rate after cytogenetic insults. Genomic instability, induced by various genetic, metabolic, and environmental factors including radiation, is the driving force of tumorigenesis. Accurate measurements of the relative biological effectiveness (RBE) is important for estimating radiation-related risks. To further understand genomic instability induced by charged particles and their RBE, we exposed human lymphocytes ex vivo, human fibroblast AG1522, human mammary epithelial cells (CH184B5F5/M10), and bone marrow cells isolated from CBA/CaH(CBA) and C57BL/6 (C57) mice to high energy protons and Fe ions. Normal human fibroblasts AG1522 have apparently normal DNA damage response and repair mechanisms, while mammary epithelial cells (M10) are deficient in the repair of DNA DSBs. Mouse strain CBA is radio-sensitive while C57 is radio-resistant. Metaphase chromosomes at different cell divisions after radiation exposure were collected and chromosome aberrations were analyzed as RBE for different cell lines exposed to different radiations at various time points up to one month post irradiation.

  15. Simulated Space Radiation: Impact of Four Different Types of High-Dose Ionizing Radiation on the Lichen Xanthoria elegans

    Science.gov (United States)

    Brandt, Annette; Meeßen, Joachim; Jänicke, Reiner U.; Raguse, Marina; Ott, Sieglinde

    2017-02-01

    This study addresses the viability of the lichen Xanthoria elegans after high-dose ionizing irradiation in the frame of the STARLIFE campaign. The first set of experiments was intended to resemble several types of galactic cosmic radiation (GCR) as present beyond the magnetic shield of Earth. In the second set of experiments, γ radiation up to 113 kGy was applied to test the limit of lichen resistance to ionizing radiation. Entire thalli of Xanthoria elegans were irradiated in the anhydrobiotic state. After STARLIFE 1, the metabolic activity of both symbionts was quantified by live/dead staining with confocal laser scanning microscopy. The photosynthetic activity was measured after the respective irradiation to assess the ability of the symbiotic green algae to restore photosynthesis after irradiation. The STARLIFE campaign complements the results of the LIFE experiments at the EXPOSE-E facility on the International Space Station by testing the model organism Xanthoria elegans on its resistance to hazardous radiation that might be accumulated during long-term space exposure. In addition, the photosynthetic activity of metabolically active lichen was investigated after X-ray irradiation up to 100 Gy (3.3 Gy/min). Since previous astrobiological experiments were mostly performed with anhydrobiotic lichen, these experiments will broaden our knowledge on the correlation of physiological state and astrobiological stressors.

  16. NONLINEAR OPTICAL FREQUENCY CONVERTER OF LASER RADIATION ON THE LBO TYPE I CRYSTALS

    Directory of Open Access Journals (Sweden)

    N. V. Kondratyuk

    2014-01-01

    Full Text Available Describes nonlinear optical frequency converter of laser radiation based on the two LBO type I crystals allowing to receive pulses of radiation at three wavelengths of 1064 nm, 532 nm and 355 nm with an adjustable pulse energy. For fine adjustment of the output pulse energy used two dual phase plates that change the orientation of the plane of polarization of the two waves in cascade third harmonic generation. Measured the efficiency of the generation of harmonics of the intensity of radiation at 1064 nm.

  17. Conducted interference on smart meters

    NARCIS (Netherlands)

    Keyer, Cornelis H.A.; Leferink, Frank

    2017-01-01

    The increasing conducted interference caused by modern electronic equipment is causing more problems for electronic, or static, energy meters. These meters are called smart meters when equipped with a communication link, and are replacing the conventional electromechanical meters. It is known that

  18. Gutenberg-Richter-type relation for laboratory fracture-induced electromagnetic radiation.

    Science.gov (United States)

    Rabinovitch, A; Frid, V; Bahat, D

    2002-01-01

    The fractal nature of electromagnetic radiation induced by uniaxial and triaxial rock fracture is considered. Both the well-known Gutenberg-Richter-type and the Benioff strain-release relationship, for earthquakes and starquakes, are shown to extend to the microscale (millimeters-centimeters). Results show that both the b value of the Gutenberg-Richter-type law and the slope of the Benioff strain-release relationship of the electromagnetic radiation signals are similar to values known for earthquakes. These results imply that a common mechanism is acting at all scales.

  19. Quantifying the contribution of different cloud types to the radiation budget in southern West Africa during the monsoon season

    Science.gov (United States)

    Hill, Peter; Allan, Richard; Bodas-Salcedo, Alejandro; Chiu, Chrstine

    2017-04-01

    The contribution of cloud to the radiation budget of southern West Africa (SWA) during the June-September monsoon season is poorly understood. Reasons for this include a lack of surface based cloud and radiation observations, uncertainty surrounding the aerosol and cloud data required for calculations of the cloud radiative effect, and infrequent clear-sky scenes that are required to estimate the top of atmosphere cloud radiative effect. An improved understanding of the contribution of cloud to the radiation budget of SWA is vital both for understanding how cloud effects the regional energy budget and for evaluation and improvement of climate models which have large radiation errors in this region. To this end, we calculate cloud radiative effects for SWA using the SOCRATES (Suite Of Community Radiative Transfer codes based on Edwards-Slingo) broadband radiative transfer scheme. We use CCCM (collocated CERES-CloudSat-CALIPSO-MODIS) data as input to radiation calculations, which we validate against coincident CERES measurements. During the monsoon season, a wide range of cloud types can be found in SWA and the radiation calculations allow us to identify multiple cloud types within a CERES footprint and thus calculate separate cloud radiative effects for each cloud type. We use these calculations to identify which cloud types are most important to the radiation and consequently energy budget of SWA.

  20. Transformer and Meter Tester

    Science.gov (United States)

    Stoms, R. M.

    1984-01-01

    Numerically-controlled 5-axis machine tool uses transformer and meter to determine and indicate whether tool is in home position, but lacks built-in test mode to check them. Tester makes possible test, and repair of components at machine rather then replace them when operation seems suspect.

  1. Effects of exposure to different types of radiation on behaviors mediated by peripheral or central systems

    Science.gov (United States)

    Rabin, B. M.; Joseph, J. A.; Erat, S.

    1998-01-01

    The effects of exposure to ionizing radiation on behavior may result from effects on peripheral or on central systems. For behavioral endpoints that are mediated by peripheral systems (e.g., radiation-induced conditioned taste aversion or vomiting), the behavioral effects of exposure to heavy particles (56Fe, 600 MeV/n) are qualitatively similar to the effects of exposure to gamma radiation (60Co) and to fission spectrum neutrons. For these endpoints, the only differences between the different types of radiation are in terms of relative behavioral effectiveness. For behavioral endpoints that are mediated by central systems (e.g., amphetamine-induced taste aversion learning), the effects of exposure to 56Fe particles are not seen following exposure to lower LET gamma rays or fission spectrum neutrons. These results indicate that the effects of exposure to heavy particles on behavioral endpoints cannot necessarily be extrapolated from studies using gamma rays, but require the use of heavy particles.

  2. The influence of surface type on the absorbed radiation by a human under hot, dry conditions

    Science.gov (United States)

    Hardin, A. W.; Vanos, J. K.

    2018-01-01

    Given the predominant use of heat-retaining materials in urban areas, numerous studies have addressed the urban heat island mitigation potential of various "cool" options, such as vegetation and high-albedo surfaces. The influence of altered radiational properties of such surfaces affects not only the air temperature within a microclimate, but more importantly the interactions of long- and short-wave radiation fluxes with the human body. Minimal studies have assessed how cool surfaces affect thermal comfort via changes in absorbed radiation by a human ( R abs) using real-world, rather than modeled, urban field data. The purpose of the current study is to assess the changes in the absorbed radiation by a human—a critical component of human energy budget models—based on surface type on hot summer days (air temperatures > 38.5∘C). Field tests were conducted using a high-end microclimate station under predominantly clear sky conditions over ten surfaces with higher sky view factors in Lubbock, Texas. Three methods were used to measure and estimate R abs: a cylindrical radiation thermometer (CRT), a net radiometer, and a theoretical estimation model. Results over dry surfaces suggest that the use of high-albedo surfaces to reduce overall urban heat gain may not improve acute human thermal comfort in clear conditions due to increased reflected radiation. Further, the use of low-cost instrumentation, such as the CRT, shows potential in quantifying radiative heat loads within urban areas at temporal scales of 5-10 min or greater, yet further research is needed. Fine-scale radiative information in urban areas can aid in the decision-making process for urban heat mitigation using non-vegetated urban surfaces, with surface type choice is dependent on the need for short-term thermal comfort, or reducing cumulative heat gain to the urban fabric.

  3. The influence of surface type on the absorbed radiation by a human under hot, dry conditions

    Science.gov (United States)

    Hardin, A. W.; Vanos, J. K.

    2017-05-01

    Given the predominant use of heat-retaining materials in urban areas, numerous studies have addressed the urban heat island mitigation potential of various "cool" options, such as vegetation and high-albedo surfaces. The influence of altered radiational properties of such surfaces affects not only the air temperature within a microclimate, but more importantly the interactions of long- and short-wave radiation fluxes with the human body. Minimal studies have assessed how cool surfaces affect thermal comfort via changes in absorbed radiation by a human (R abs) using real-world, rather than modeled, urban field data. The purpose of the current study is to assess the changes in the absorbed radiation by a human—a critical component of human energy budget models—based on surface type on hot summer days (air temperatures > 38.5∘C). Field tests were conducted using a high-end microclimate station under predominantly clear sky conditions over ten surfaces with higher sky view factors in Lubbock, Texas. Three methods were used to measure and estimate R abs: a cylindrical radiation thermometer (CRT), a net radiometer, and a theoretical estimation model. Results over dry surfaces suggest that the use of high-albedo surfaces to reduce overall urban heat gain may not improve acute human thermal comfort in clear conditions due to increased reflected radiation. Further, the use of low-cost instrumentation, such as the CRT, shows potential in quantifying radiative heat loads within urban areas at temporal scales of 5-10 min or greater, yet further research is needed. Fine-scale radiative information in urban areas can aid in the decision-making process for urban heat mitigation using non-vegetated urban surfaces, with surface type choice is dependent on the need for short-term thermal comfort, or reducing cumulative heat gain to the urban fabric.

  4. Calibration services for medical applications of radiation

    Energy Technology Data Exchange (ETDEWEB)

    DeWerd, L.A.

    1993-12-31

    Calibration services for the medical community applications of radiation involve measuring radiation precisely and having traceability to the National Institute of Standards and Technology (NIST). Radiation therapy applications involve the use of ionization chambers and electrometers for external beams and well-type ionization chamber systems as well as radioactive sources for brachytherapy. Diagnostic x-ray applications involve ionization chamber systems and devices to measure other parameters of the x-ray machine, such as non-invasive kVp meters. Calibration laboratories have been established to provide radiation calibration services while maintaining traceability to NIST. New radiation applications of the medical community spur investigation to provide the future calibration needs.

  5. The stimulation of auroral kilometric radiation by type III solar radio bursts

    Science.gov (United States)

    Calvert, W.

    1981-01-01

    It has been found that the onset of auroral kilometric radiation (AKR) frequently coincides with the arrival of type III solar radio bursts. Although the AKR onsets are usually abrupt and appear to be spontaneous, they sometimes develop from a discrete frequency near the leading edge of a type III burst or sometimes occur at progressively lower frequencies following that edge. From this, and the absence of the related solar electrons in specific cases, it was concluded that the incoming type III waves were sometimes responsible for stimulating auroral kilometric radiation. It was estimated that intense, isolated type III bursts were capable of stimulating AKR roughly one third of the time, and that at least ten percent of the observed AKR onsets could be attributed to these and weaker bursts, including some barely detectable by the ISEE plasma wave receivers.

  6. Inhomogeneous generalizations of Bianchi Type VIh universes with stiff perfect fluid and radiation

    Science.gov (United States)

    Roy, S. R.; Prasad, A.

    1995-03-01

    Families of inhomogeneous models filled with a stiff perfect fluid and radiation have been derived in which there is no flow of total momentum. The models are generalizations of those of Bianchi Type VIh and are discussed for some particular forms of the arbitrary functions appearing in them.

  7. The dynamical influence of radiation in type 1 X-ray bursts

    Science.gov (United States)

    Walker, Mark A.; Meszaros, P.

    1989-01-01

    Consideration is given to the dynamical effects upon an accretion disk of incident radiation generated by thermonuclear burning on the surface of a nonrotating, nonmagnetic neutron star - as exemplified in type 1 X-ray burst sources. Under these conditions, it is found that the torque applied by the radiation field leads to enhanced mass transfer, and the associated accretion power contributes substantially to the total luminosity of the burst. However, this accretion will provide a smaller fraction of the total burst energy if the neutron star possesses a magnetosphere or is in rapid rotation.

  8. Comparative study of natural and synthetic type-IIa diamond radiation detectors

    Science.gov (United States)

    Zaletaev, Nicolas B.; Alekseyev, Andrey G.; Amosov, Vladimir N.; Feigelson, Boris N.

    2000-11-01

    Diamond has the highest radiation-damage level among radiation-detector semiconductor materials. Besides, low carbon nucleus charge, Z equals 6, provides tissue equivalence of diamond detectors. However, essential restrictions are imposed on production of natural-diamond detectors by extremely low final yield of selection procedure and corresponding expensiveness of high-quality type IIa natural diamonds. The solution of this problem could be found through the development of single-crystal synthetic-diamond detectors. Basic radiation-response properties of high-pressure high- temperature (HPHT) single-crystal synthetic-diamond (SD) detectors and natural-diamond (ND) detectors made of extremely low nitrogen content (type IIa) material were comparatively studied under hard X-ray, UV, and alpha-particle irradiation. Four orders of magnitude higher steady-state responsivity to radiation has been observed for SD detectors. The gain evaluated under UV irradiation exceeded 6000 (the corresponding value of responsivity was above 1000 A/W). The study of alpha-particle-induced electromotive force (EMF) polarity has revealed the opposite type of surface bending of energy bands in synthetic and natural diamonds. The difference in detector performance could be explained in terms of presented model of charge carrier injection and transport in diamond.

  9. Radiation therapy for wet type age-related macular degeneration. Long term follow-up results

    Energy Technology Data Exchange (ETDEWEB)

    Sasai, Keisuke; Hiraoka, Masahiro; Mandai, Michiyo; Takahashi, Masayo; Honda, Yoshihito [Kyoto Univ. (Japan). Faculty of Medicine

    1998-12-01

    Between April, 1994 and July, 1995, 33 patients with occult type choroidal neovascularization (CNV) with or without the classical type CNV of the wet type age-related macular degeneration ARMD were treated with radiation therapy (10 Gy/5 fx/1 week or 20 Gy/10 fx/2 weeks). This phase I/II study showed that radiation therapy seems to be useful for CNV during the first 12 months. Some eyes which initially showed good response to irradiation began to lose their visual acuity. However, the dose of 20 Gy in 10 fractions seemed useful to maintain the visual acuity better than 0.1 in this long term follow-up study (24 months). (author)

  10. Comparison of five portable peak flow meters

    Directory of Open Access Journals (Sweden)

    Glaucia Nency Takara

    2010-01-01

    Full Text Available OBJECTIVE: To compare the measurements of spirometric peak expiratory flow (PEF from five different PEF meters and to determine if their values are in agreement. Inaccurate equipment may result in incorrect diagnoses of asthma and inappropriate treatments. METHODS: Sixty-eight healthy, sedentary and insufficiently active subjects, aged from 19 to 40 years, performed PEF measurements using Air Zone®, Assess®, Galemed®, Personal Best® and Vitalograph® peak flow meters. The highest value recorded for each subject for each device was compared to the corresponding spirometric values using Friedman's test with Dunn's post-hoc (p<0.05, Spearman's correlation test and Bland-Altman's agreement test. RESULTS: The median and interquartile ranges for the spirometric values and the Air Zone®, Assess®, Galemed®, Personal Best® and Vitalograph® meters were 428 (263-688 L/min, 450 (350-800 L/min, 420 (310-720 L/min, 380 (300-735 L/min, 400 (310-685 L/min and 415 (335-610 L/min, respectively. Significant differences were found when the spirometric values were compared to those recorded by the Air Zone® (p<0.001 and Galemed ® (p<0.01 meters. There was no agreement between the spirometric values and the five PEF meters. CONCLUSIONS: The results suggest that the values recorded from Galemed® meters may underestimate the actual value, which could lead to unnecessary interventions, and that Air Zone® meters overestimate spirometric values, which could obfuscate the need for intervention. These findings must be taken into account when interpreting both devices' results in younger people. These differences should also be considered when directly comparing values from different types of PEF meters.

  11. Comparison of five portable peak flow meters.

    Science.gov (United States)

    Takara, Glaucia Nency; Ruas, Gualberto; Pessoa, Bruna Varanda; Jamami, Luciana Kawakami; Di Lorenzo, Valéria Amorim Pires; Jamami, Mauricio

    2010-05-01

    To compare the measurements of spirometric peak expiratory flow (PEF) from five different PEF meters and to determine if their values are in agreement. Inaccurate equipment may result in incorrect diagnoses of asthma and inappropriate treatments. Sixty-eight healthy, sedentary and insufficiently active subjects, aged from 19 to 40 years, performed PEF measurements using Air Zone, Assess, Galemed, Personal Best and Vitalograph peak flow meters. The highest value recorded for each subject for each device was compared to the corresponding spirometric values using Friedman's test with Dunn's post-hoc (p<0.05), Spearman's correlation test and Bland-Altman's agreement test. The median and interquartile ranges for the spirometric values and the Air Zone, Assess, Galemed, Personal Best and Vitalograph meters were 428 (263-688 L/min), 450 (350-800 L/min), 420 (310-720 L/min), 380 (300-735 L/min), 400 (310-685 L/min) and 415 (335-610 L/min), respectively. Significant differences were found when the spirometric values were compared to those recorded by the Air Zone(R) (p<0.001) and Galemed (p<0.01) meters. There was no agreement between the spirometric values and the five PEF meters. The results suggest that the values recorded from Galemed meters may underestimate the actual value, which could lead to unnecessary interventions, and that Air Zone meters overestimate spirometric values, which could obfuscate the need for intervention. These findings must be taken into account when interpreting both devices' results in younger people. These differences should also be considered when directly comparing values from different types of PEF meters.

  12. Improving the radiation hardness properties of silicon detectors using oxygenated n-type and p-type silicon

    CERN Document Server

    Casse, G L; Hanlon, M

    2000-01-01

    The degradation of the electrical properties of silicon detectors exposed to 24 GeV/c protons were studied using pad diodes made from different silicon materials. Standard high-grade p-type and n-type substrates and oxygenated n-type substrates have been used. The diodes were studied in terms of reverse current (I/sub r/) and full depletion voltage (V/sub fd/) as a function of fluence. The oxygenated devices from different suppliers with a variety of starting materials and techniques, all show a consistent improvement of the degradation rate of V/sub fd/ and CCE compared to un- oxygenated substrate devices. Radiation damage of n-type detectors introduces stable defects acting as effective p-type doping and leads to the change of the conductivity type of the silicon bulk (type inversion) at a neutron equivalent fluence of a few 10/sup 13/ cm/sup -2/. The diode junction after inversion migrates from the original side to the back plane of the detector. The migration of the junction is avoided using silicon detec...

  13. Smart metering design and applications

    CERN Document Server

    Weranga, K S K; Chandima, D P

    2013-01-01

    Taking into account the present day trends and the requirements, this Brief focuses on smart metering of electricity for next generation energy efficiency and conservation. The contents include discussions on the smart metering concepts and existing technologies and systems as well as design and implementation of smart metering schemes together with detailed examples.

  14. Peak flow meter use - slideshow

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/presentations/100202.htm Peak flow meter use - Series—Peak flow meter use - part one To use the sharing ... slide 7 out of 7 Overview A peak flow meter helps you check how well your asthma ...

  15. Good standards for smart meters

    NARCIS (Netherlands)

    Hoenkamp, R.A.; Huitema, G.B.

    2012-01-01

    This paper examines what lessons can be learned from the rollout of smart meters in the Netherlands to improve the European smart meter standardization. This study is based on the case of the Dutch meter rollout which preparations started in 2005 but finally was delayed until 2011 by governmental

  16. Measurement of solar ultraviolet radiation intensity type A and B in Qazvin (2013-14

    Directory of Open Access Journals (Sweden)

    SAR. Babaee

    2016-08-01

    Full Text Available Background: Solar ultraviolet radiation (UVR is considered one of the most important biological risk factors in the world. Most health damages from solar ultraviolet radiation at ground level are mainly caused by UVA and UVB spectrums. Objective: The aim of this study was to Measure the solar ultraviolet radiation intensity type A and B in Qazvin city. Methods: In this cross-sectional study, the intensity of solar ultraviolet radiation type A and B was measured in Qazvin on years of 2013-14 (during one year every monthly at three times, in the morning, afternoon and evening by using a UV Radiometer. Data were analyzed using descriptive statistics. Findings: The maximum average intensity of UVA and UVB rays during the one year with 28.36±1.88 W/m2 and 0.156±0.035 W/m2 respectively was in Tir month (June 22–July 22 and the minimum average intensity of UVA and UVB rays with 10.36±0.83 W/m2 and 0.041±0.010 W/m2 respectively was in Dai month (December 22–January 20. Conclusion: With regards to the results, it is recommended that individuals were less exposed to exposure time with direct sunshine and use appropriate protective measures such as; wear appropriate clothing, sunglasses, and sunscreen.

  17. Advanced metering techniques

    Energy Technology Data Exchange (ETDEWEB)

    Szydlowski, R.F.

    1993-01-01

    The goal of the US Department of Energy Federal Energy Management Program (FEMP) is to facilitate energy-efficiency improvements at federal facilities. This is accomplished by a balanced program of technology development, facility assessment, and use of cost-sharing procurement mechanisms. Technology development focuses upon the tools and procedures used to identify and evaluate efficiency improvements. For facility assessment, FEMP provides metering equipment and trained analysts to federal agencies exhibiting a commitment to improve energy-use efficiency. To assist in implementing energy-efficiency measures, FEMP helps federal agencies with identifying efficiency opportunities and in implementing energy-efficiency and demand-side management programs at federal sites. As the lead laboratory for FEMP, Pacific Northwest Laboratory (PNL) provides technical assistance to federal agencies to better understand and characterize energy systems. The US Army Forces Command (FORSCOM) has tasked PNL to provide technical assistance to characterize and modernize energy systems at FORSCOM installations. As part of that technical assistance, PNL performed an in-depth examination of automatic meter-reading system technologies currently available. The operating characteristics and relative merits of all the major systems were reviewed in the context of applicability to federal installations. That review is documented in this report.

  18. KVP meter errors induced by plastic wrap

    Energy Technology Data Exchange (ETDEWEB)

    Jefferies, D.; Morris, J.W.; White, V.P. (Southern Illinois Univ., Carbondale (USA))

    1991-02-01

    The purpose of this study was to determine whether erroneous kVp meter readings, induced by plastic wrap, affected the actual kVp (output) of a dental X-ray machine. To evaluate the effect of plastic wrap on dental X-ray machine kVp meters, a radiation output device was used to measure output in mR/ma.s. An intraoral dental X-ray unit (S.S. White Model {number sign}90W) was used to make the exposures. First, the kVp meter was not covered with plastic wrap and output readings were recorded at various kVp settings with the milliamperage and time held constant. Secondly, the same kVp settings were selected before the plastic wrap was placed. Milliamperage and time were again held to the same constant. The X-ray console was then covered with plastic wrap prior to measuring the output for each kVp. The wrap possessed a static charge. This charge induced erroneous kVp meter readings. Out-put readings at the various induced kVp settings were then recorded. A kVp of 50 with no wrap present resulted in the same output as a kVp of 50 induced to read 40 or 60 kVp by the presence of wrap. Similar results were obtained at other kVp settings. This indicates that the plastic wrap influences only the kVp meter needle and not the actual kilovoltage of the X-ray machine. Dental X-ray machine operators should select kVp meter readings prior to placing plastic wrap and should not adjust initial settings if the meter is deflected later by the presence of wrap. The use of such a procedure will result in proper exposures, fewer retakes, and less patient radiation. If plastic wrap leads to consistent exposure errors, clinicians may wish to use a 0.5% sodium hypochlorite disinfectant as an alternative to the barrier technique.

  19. CERN Radiation Protection (RP) calibration facilities

    CERN Document Server

    AUTHOR|(CDS)2082069; Macián-Juan, Rafael

    Radiation protection calibration facilities are essential to ensure the correct operation of radiation protection instrumentation. Calibrations are performed in specific radiation fields according to the type of instrument to be calibrated: neutrons, photons, X-rays, beta and alpha particles. Some of the instruments are also tested in mixed radiation fields as often encountered close to high-energy particle accelerators. Moreover, calibration facilities are of great importance to evaluate the performance of prototype detectors; testing and measuring the response of a prototype detector to well-known and -characterized radiation fields contributes to improving and optimizing its design and capabilities. The CERN Radiation Protection group is in charge of performing the regular calibrations of all CERN radiation protection devices; these include operational and passive dosimeters, neutron and photon survey-meters, and fixed radiation detectors to monitor the ambient dose equivalent, H*(10), inside CERN accelera...

  20. Multidimensional radiative transfer calculations of the light curves and spectra of Type Ia supernovae

    Energy Technology Data Exchange (ETDEWEB)

    Kasen, D; Woosley, S E [Department of Physics and Astronomy, University of California, Santa Cruz, CA 95064 (United States); Thomas, R C [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Roepke, F [Max Plank Institute for Astrophysics, Garching (Germany)], E-mail: kasen@ucolick.org

    2008-07-15

    The explosion of a white dwarf star in a Type Ia supernova (SN Ia) explosion leads to the burning and ejection of stellar material at a few percent of the speed of light. The spectacle we observe in the months that follow is from the leaking of radiation from this glowing mass of radioactive debris. The modeling of SN Ia light curves and spectra represents a complex problem in time-dependent radiative transfer. Here we discuss numerical methods, in particular Monte Carlo methods, for calculating 3D multi-wavelength radiative transport on massively parallel machines. Our approach involves a newly developed domain decomposition technique in which the memory load is distributed over multiple processors and photon packets are communicated from node to node. We present results for 2-dimensional models that explore white dwarf explosions over a range of explosion paradigms and ignition conditions. These models give insight into how variations in the initial conditions of the explosion affect the light curve we finally observe. We conclude with an outlook (and some initial results) for large scale 3D radiation transport calculations of SNe Ia in an era of petascale computing.

  1. Prediction of the radiation situation during conditioned radioactive waste storage in hangar-type storage facilities

    Science.gov (United States)

    Rosnovskii, S. V.; Bulka, S. K.

    2014-02-01

    An original technology for the conditioning of solidified radioactive waste was developed by the Novovoronezh nuclear power plant (NPP) staff. The technology provides for waste placement inside NZK-150-1.5P containers with their further storage at light hangar-type storage facilities. A number of technical solutions were developed that allow for reducing the gamma-radiation dose rate from the package formed. A methodology for prediction of the radiation situation around hangars, depending on the radiation characteristics of irrecoverable shielding containers (ISCs) located in the peripheral row of a storage facility, was developed with the purpose of assuring safe storage. Based on empirical data, the field background gamma-radiation dose rate at an area as a function of the average dose rate at the hangar surface and the average dose rate close packages, placed in the peripheral row of the storage facility, was calculated. The application of the developed methodology made it possible to reduce by ten times the expenditures for the conditioning and holding of solidified radioactive waste (SRW) while unconditionally providing storage safety.

  2. Radiation-induced lung fibrosis in a tumor-bearing mouse model is associated with enhanced Type-2 immunity.

    Science.gov (United States)

    Chen, Jing; Wang, Yacheng; Mei, Zijie; Zhang, Shimin; Yang, Jie; Li, Xin; Yao, Ye; Xie, Conghua

    2016-03-01

    Lung fibrosis may be associated with Type-2 polarized inflammation. Herein, we aim to investigate whether radiation can initiate a Type-2 immune response and contribute to the progression of pulmonary fibrosis in tumor-bearing animals. We developed a tumor-bearing mouse model with Lewis lung cancer to receive either radiation therapy alone or radiation combined with Th1 immunomodulator unmethylated cytosine-phosphorothioate-guanine containing oligodeoxynucleotide (CpG-ODN). The Type-2 immune phenotype in tumors and the histological grade of lung fibrosis were evaluated in mice sacrificed three weeks after irradiation. Mouse lung tissues were analyzed for hydroxyproline and the expression of Type-1/Type-2 key transcription factors (T-bet/GATA-3). The concentration of Type-1/Type-2 cytokines in serum was measured by cytometric bead array. Lung fibrosis was observed to be more serious in tumor-bearing mice than in normal mice post-irradiation. The fibrosis score in irradiated tumor-bearing mice on Day 21 was 4.33 ± 0.82, which was higher than that of normal mice (2.00 ± 0.63; P Type-2 immunity in tumors appeared to affect the outcome of radiation damage and might be of interest for future studies on developing approaches in which Type-1-related immunotherapy and radiotherapy are used in combination. © The Author 2015. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  3. Cosmic radiation and airline pilots: Exposure pattern as a function of aircraft type

    Energy Technology Data Exchange (ETDEWEB)

    Tveten, U.; Haldorsen, T.; Reitan, J

    2000-07-01

    The project presented here has been carried out as part of an epidemiological project on Norwegian aircraft personnel, entitled 'Exposure to low level ionising radiation and incidence of cancer in airline pilots and crew'. The purpose of the main project is to determine if there may be a relationship between exposure to cosmic radiation at aircraft cruising altitudes and the incidence of cancer. The methodology used as basis for estimating the radiation exposures is presented. The information used as basis for the dose estimations comes from a variety of sources: the files at the Personnel Licensing Section and the Aviation Medical Section of Norwegian Aviation Administration, the route tables of Scandinavian Airlines System (SAS), large amounts of expert information contributed by members of the Pilot's Associations in Norway and a couple of non-Norwegian pilots and from other members of the staff of SAS and other airlines. The estimation for each pilot was based on individual information of annual block hours and an estimated doserate for each type of aircraft. The latter was estimated as a weighted average of CARI-estimated doses on a selection of routes flown by the airplanes in the different time periods. The project includes all pilots that have been licensed in Norway since 1946. These pilots have been flying a large variety of different types of aircraft and routes. The cosmic radiation intensity is a function of altitude in the atmosphere and, less markedly, of geographical latitude and of the intensity of the radiation from the sun (quantified as the heliocentric potential). Different types of aircraft fly at different altitudes and are used for different purposes (passenger traffic, cargo, air photography, preparation of maps etc) and used on different routes. The end results of the project described in this article are radiation exposures per block hour for each type of aircraft, and for each individual year (the differences between years

  4. Modest increased sensitivity to radiation oncogenesis in ATM heterozygous versus wild-type mammalian cells

    Science.gov (United States)

    Smilenov, L. B.; Brenner, D. J.; Hall, E. J.

    2001-01-01

    Subpopulations that are genetically predisposed to radiation-induced cancer could have significant public health consequences. Individuals homozygous for null mutations at the ataxia telangiectasia gene are indeed highly radiosensitive, but their numbers are very small. Ataxia Telangiectasia heterozygotes (1-2% of the population) have been associated with somewhat increased radiosensitivity for some end points, but none directly related to carcinogenesis. Here, intralitter comparisons between wild-type mouse embryo fibroblasts and mouse embryo fibroblasts carrying ataxia telangiectasia mutated (ATM) null mutation indicate that the heterozygous cells are more sensitive to radiation oncogenesis than their normal, litter-matched, counterparts. From these data we suggest that Ataxia Telangiectasia heterozygotes could indeed represent a societally-significant radiosensitive human subpopulation.

  5. A new measurement method for separating airborne and structureborne noise radiated by aircraft type panels

    Science.gov (United States)

    Mcgary, M. C.

    1982-01-01

    The theoretical basis for and experimental validation of a measurement method for separating airborne and structure borne noise radiated by aircraft type panels are presented. An extension of the two microphone, cross spectral, acoustic intensity method combined with existing theory of sound radiation of thin shell structures of various designs, is restricted to the frequency range below the coincidence frequency of the structure. Consequently, the method lends itself to low frequency noise problems such as propeller harmonics. Both an aluminum sheet and two built up aircraft panel designs (two aluminum panels with frames and stringers) with and without added damping were measured. Results indicate that the method is quick, reliable, inexpensive, and can be applied to thin shell structures of various designs.

  6. In vitro/in vivo correlation and modeling of emitted dose and lung deposition of inhaled salbutamol from metered dose inhalers with different types of spacers in noninvasively ventilated patients.

    Science.gov (United States)

    Hussein, Raghda R S; M A Ali, Ahmed; Salem, Heba F; Abdelrahman, Maha M; Said, Amira S A; Abdelrahim, Mohamed E A

    2017-11-01

    Substituting spacer by another in noninvasive ventilation (NIV) involves many variables, e.g. total emitted dose (TED), mass median aerodynamic diameter (MMAD), type of spacer, total lung deposition and total systemic absorption, which must be adjusted to ensure patient optimum therapy. Data mining based on artificial neural networks and genetic algorithms were used to model in vitro inhalation process, predict and optimize bioavailability from inhaled doses delivered by metered dose inhaler (MDI) using different spacers in NIV. Modeling of data indicated that in vitro performance of MDI-spacer systems was dependent mainly on fine particle dose (FPD), fine particle fraction (FPF), MMAD and to lesser extent on spacer type. Ex vivo model indicated that amount of salbutamol collected on facemask filter was directly affected by FPF. In vivo model (24hQ) depended directly on spacer type, FPF and TED. Female patients showed higher 0.5hQ and 24hQ values than males. AeroChamber VC spacer demonstrated higher TED and 24hQ in vivo values. Results indicated suitability of MDI-spacer systems in achieving appropriate in vitro inhalation performance. The possibility of modeling and predicting both ex vivo and in vivo capabilities of MDI-spacer systems from knowledge of in vitro attributes enabled detailed focus on important variables required to deliver safe and accurate doses of salbutamol to ventilated patients.

  7. Micro-gen metering solutions

    Energy Technology Data Exchange (ETDEWEB)

    Elland, J.; Dickson, J.; Cranfield, P.

    2003-07-01

    This report summarises the results of a project to investigate the regulation of domestic electricity metering work and identify the most economic options for micro-generator installers to undertake work on electricity meters. A micro-generation unit is defined as an energy conversion system converting non-electrical energy into electrical energy and can include technologies such as photovoltaic systems, small-scale wind turbines, micro-hydroelectric systems, and combined heat and power systems. Details of six tasks are given and cover examination of the existing framework and legal documentation for metering work, the existing technical requirements for meter operators, meter operator personnel accreditation, appraisal of options for meter changes and for micro-generation installation, document change procedures, industry consultation, and a review of the costs implications of the options.

  8. Distinct impact of different types of aerosols on surface solar radiation in China

    Science.gov (United States)

    Yang, Xin; Zhao, Chuanfeng; Zhou, Lijing; Wang, Yang; Liu, Xiaohong

    2016-06-01

    Observations of surface direct solar radiation (DSR) and visibility, particulate matter with aerodynamic diameters less than 2.5 µm (PM2.5), together with the aerosol optical thickness (AOT) taken from Moderate-Resolution Imaging Spectroradiometer and Multiangle Imaging Spectroradiometer, were investigated to gain insight into the impact of aerosol pollution on surface solar radiation in China. The surface DSR decreased during 2004-2014 compared with 1993~2003 over eastern China, but no clear reduction was observed in remote regions with cleaner air. Significant correlations of visibility, PM2.5, and regionally averaged AOT with the surface DSR over eastern China indicate that aerosol pollution greatly affects the energy available at the surface. The net loss of surface solar radiation also reduces the surface ground temperature over eastern China. However, the slope of the linear variation of the radiation with respect to atmospheric visibility is distinctly different at different stations, implying that the main aerosol type varies regionally. The largest slope value occurs at Zhengzhou and indicates that the aerosol absorption in central China is the highest, and lower slope values suggest relatively weakly absorbing types of aerosols at other locations. The spatial distribution of the linear slopes agrees well with the geographical distribution of the absorbing aerosols derived from the Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations and Ozone Monitoring Instrument over China. The regional correlation between a larger slope value and higher absorbance properties of aerosols indicates that the net effects of aerosols on the surface solar energy and corresponding climatic effects are dependent on both aerosol amount and optical properties.

  9. Application of an additive-type mixed probability distribution to the analysis of radiation from a mixture of radioactive sources

    Directory of Open Access Journals (Sweden)

    Dolićanin-Đekić Diana

    2013-01-01

    Full Text Available This paper investigates the possibility of distinguishing between the effects of radiation coming from two or more radioactive isotopes, by using methods of statistical mathematics. The procedure uses a mixed distribution of an additive type. Mathematical treatment is demonstrated herein on an example of analysis of composite radiation from two radioactive sources.

  10. Optimal water meter selection system | Johnson | Water SA

    African Journals Online (AJOL)

    The relative frequency of the volume of water passing through a meter at various flow rates and the weighted accuracies of these measured volumes play a pivotal role in establishing a common comparison reference. The time unit selected to calculate the volume of water passing through the meter is guided by the type of ...

  11. Radiation dynamics in X-ray binaries. I - Type 1 bursts. II - Type 2 bursts. III - Extremely compact objects

    Science.gov (United States)

    Walker, Mark A.

    1992-01-01

    Equations describing the evolution of a thin, axisymmetric, viscous, relativistic, irradiated accretion disk are presented, as well as numerical solutions of these equations in the case where irradiation results from a thermonuclear flash on the surface of the accreting neutron star. These calculations verify the notion that the radiation torque induces a substantial increase in the accretion rate, during a type 1 X-ray burst, and provide insight into the factors which influence the dynamical response of the disk. A new model for the source XBT 1730-335, the rapid burster, is presented. Temporal and spectral properties are calculated. The rapid burster is found to be a nonmagnetic, 'critically compact', slowly rotating neutron star in a highly eccentric binary system with a period of 6 mo. The spectral modifications which arise from the scattering of photons by accretion disks around nonmagnetic neutron stars are calculated. The 'black hole candidates' are interpreted as extremely compact stars.

  12. The development of wireless radiation dose monitoring using smart phone

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jin Woo; Jeong, Gyo Seong; Lee, Yun Jong [Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup (Korea, Republic of); Kim, Chong Yeal [Chonbuk National University, Jeonju (Korea, Republic of); Lim, Chai Wan [REMTECH, Seoul (Korea, Republic of)

    2016-11-15

    Radiation workers at a nuclear facility or radiation working area should hold personal dosimeters. some types of dosimeters have functions to generate audible or visible alarms to radiation workers. However, such devices used in radiation fields these days have no functions to communicate with other equipment or the responsible personnel. our project aims at the development of a remote wireless radiation dose monitoring system that can be utilized to monitor the radiation dose for radiation workers and to notify the radiation protection manager of the dose information in real time. We use a commercial survey meter for personal radiation measurement and a smart phone for a mobile wireless communication tool and a Beacon for position detection of radiation workers using Blue tooth communication. In this report, the developed wireless dose monitoring of cellular phone is introduced.

  13. Use of portable exposure meters for comparing mobile phone base station radiation in different types of areas in the cities of Basel and Amsterdam

    NARCIS (Netherlands)

    Urbinello, D.; Huss, A.|info:eu-repo/dai/nl/331385880; Beekhuizen, J.|info:eu-repo/dai/nl/34472641X; Vermeulen, R.|info:eu-repo/dai/nl/216532620; Röösli, M.

    2014-01-01

    BACKGROUND: Radiofrequency electromagnetic fields (RF-EMF) are highly variable and differ considerably within as well as between areas. Exposure assessment studies characterizing spatial and temporal variation are limited so far. Our objective was to evaluate sources of data variability and the

  14. Prevention of ultraviolet radiation-induced immunosuppression by sunscreen in Candida albicans-induced delayed-type hypersensitivity

    OpenAIRE

    Chen, Quan; LI, RUNXIANG; Zhao, Xiaoxia; LIANG, BIHUA; MA, SHAOYIN; Li, Zhenjie; ZHU, HUILAN

    2016-01-01

    Ultraviolet (UV) radiation-induced immunosuppression leading to skin cancer has received increased attention in previous years. The present study aimed to investigate the immunoprotection offered by Anthelios sunscreen in a mouse model of Candida albicans-induced delayed-type hypersensitivity. Anthelios sunscreen was applied to the skin on the dorsal skin of BALB/c mice treated with a sub-erythema dose of solar-simulated radiation. Delayed-type hypersensitivity was induced by immunization wit...

  15. Demonstration of the synchrotron-type spectrum of laser-produced Betatron radiation

    CERN Document Server

    Fourmaux, S; Phuoc, K Ta; Leguay, P M; Payeur, S; Lassonde, P; Gnedyuk, S; Lebrun, G; Fourment, C; Malka, V; Sebban, S; Rousse, A; Kieffer, J C

    2011-01-01

    Betatron X-ray radiation in laser-plasma accelerators is produced when electrons are accelerated and wiggled in the laser-wakefield cavity. This femtosecond source, producing intense X-ray beams in the multi kiloelectronvolt range has been observed at different interaction regime using high power laser from 10 to 100 TW. However, none of the spectral measurement performed were at sufficient resolution, bandwidth and signal to noise ratio to precisely determine the shape of spectra with a single laser shot in order to avoid shot to shot fluctuations. In this letter, the Betatron radiation produced using a 80 TW laser is characterized by using a single photon counting method. We measure in single shot spectra from 8 to 21 keV with a resolution better than 350 eV. The results obtained are in excellent agreement with theoretical predictions and demonstrate the synchrotron type nature of this radiation mechanism. The critical energy is found to be Ec = 5.6 \\pm 1 keV for our experimental conditions. In addition, th...

  16. Effects of radiation type and delivery mode on a radioresistant eukaryote Cryptococcus neoformans.

    Science.gov (United States)

    Shuryak, Igor; Bryan, Ruth A; Broitman, Jack; Marino, Stephen A; Morgenstern, Alfred; Apostolidis, Christos; Dadachova, Ekaterina

    2015-06-01

    Most research on radioresistant fungi, particularly on human pathogens such as Cryptococcus neoformans, involves sparsely-ionizing radiation. Consequently, fungal responses to densely-ionizing radiation, which can be harnessed to treat life-threatening fungal infections, remain incompletely understood. We addressed this issue by quantifying and comparing the effects of densely-ionizing α-particles (delivered either by external beam or by (213)Bi-labeled monoclonal antibodies), and sparsely-ionizing (137)Cs γ-rays, on Cryptococcus neoformans. The best-fit linear-quadratic parameters for clonogenic survival were the following: α = 0.24 × 10(-2) Gy(-1) for γ-rays and 1.07 × 10(-2) Gy(-1) for external-beam α-particles, and β = 1.44 × 10(-5) Gy(-2) for both radiation types. Fungal cell killing by radiolabeled antibodies was consistent with predictions based on the α-particle dose to the cell nucleus and the linear-quadratic parameters for external-beam α-particles. The estimated RBE (for α-particles vs. γ-rays) at low doses was 4.47 for the initial portion of the α-particle track, and 7.66 for the Bragg peak. Non-radiological antibody effects accounted for up to 23% of cell death. These results quantify the degree of C. neoformans resistance to densely-ionizing radiations, and show how this resistance can be overcome with fungus-specific radiolabeled antibodies. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Well profile meter

    Energy Technology Data Exchange (ETDEWEB)

    Zhivotovskiy, Iz.Z.; Iskenderov, V.G.; Perelman, G.Ya.

    1982-01-01

    A well profile meter is proposed which contains in-series connected measurement levers, remote measuring system, signal summators of lever pairs arranged in one vertical plain, and recorders, one of which recorded the operational, and the other all the measurement information. It is distinguished by the fact that in order to exclude ambiguity in determining the intervals of possible groove formation and surplus information recorded by the recorder of all measurement information, it is equipped with threshold blocks for isolating signals corresponding to the minimum and maximum diameters, storage circuit, accumulator, control circuit, synchronization circuit and input keys of the recorder of the entire measurement information. In this case the inlet of the synchronization circuit is connected to the remote measurement system, and one of the outlets is connected to the parallel included inlets of the threshold blocks for isolating signals corresponding to the minimum and maximum diameters. The other outlet of the synchronization circuit is connected to the parallel included inlets of their storage circuit, accumulator and control circuit. The inlet keys of the recorder of all the measurement information are connected by their inlets to the inlets of the summator of the lever pairs and the outlet of the control circuit. The outlets are connected to the recorder of all measurement information, the outlet of the threshold block of signal isolation corresponding to the maximum diameter, through the storage circuit is connected to 1 of the inlets of the recorder of operational information. The outlet of the threshold block of signal isolation corresponding to the minimum diameter is connected through the accumulator to the other inlet of the recorder of operational information, while the outlets of the storage circuit and the accumulator are connected to the inlets of the control circuit.

  18. Topical Metered-dosing Dispenser Performance Evaluation.

    Science.gov (United States)

    Liu, Qiang; Kupiec, Thomas C; Vu, Nicole T

    2016-01-01

    Topical metered-dosing dispensers are designed for dosing accuracy and ease-of-use by the patients while protecting the packaged products from environmental exposure and contamination. The objective of this study was to evaluate the accuracy, precision, and residual of available topical metered-dosing dispensers with different types of topical cream for practical application. Triplicate samples of five different dispensers were tested. This test was completed using three types of commercial topical cream-bases of dissimilar Total Active Pharmaceutical Ingredient Load Percentages, Transdermal Penetration Percentages, and Specific Gravities. The dispensers were evaluated according to specified dose-uniformity criteria for a total dispensing capacity of 30 mL at 0.5 mL per dose for 60 doses. The study shows Topi-CLICK performed with the best precision and accuracy of dosing in comparison to the airless-pump type dispensers. While the dispensing was highly variable with airless pumps and may require calibration for each packaged product, remarkably the performance of Topi-CLICK was not affected by different types of cream-bases and does not require additional metering calibration. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  19. Metering Wheel-Wire Track Wire Boom Deployment Mechanism

    Science.gov (United States)

    Granoff, Mark S.

    2014-01-01

    The NASA MMS Spin Plane Double Probe (SDP) Deployer utilizes a helical path, rotating Metering Wheel and a spring loaded Wire "Holding" Track to pay out a "fixed end" 57 meter x 1.5 mm diameter Wire Boom stored between concentric storage cylinders. Unlike rotating spool type storage devices, the storage cylinders remain stationary, and the boom wire is uncoiled along the length of the cylinder via the rotation of the Metering Wheel. This uncoiling action avoids the need for slip-ring contacts since the ends of the wire can remain stationary. Conventional fixed electrical connectors (Micro-D type) are used to terminate to operational electronics.

  20. Smart Metering System for Microgrids

    DEFF Research Database (Denmark)

    Palacios-Garcia, Emilio; Guan, Yajuan; Savaghebi, Mehdi

    2015-01-01

    Smart meters are the cornerstone in the new conception of the electrical network or Smart Grid (SG), providing detailed information about users' energy consumption and allowing the suppliers to remotely collect data for billing. Nevertheless, their features are not only useful for the energy...... will expose an example of Smart Meters integration in a Microgrid scenario, which is the Intelligent Microgrid Lab of Aalborg University (AAU). To do this, first the installation available in the Microgrid Lab will be introduced. Then, three different test scenarios and their respective results...... will be presented, regarding the capabilities of this system and the advantages of integration the Smart Meters information in the Microgrid control....

  1. A compact laparoscope type radiation source for the pin-point cancer treatment using a femtosecond laser

    Science.gov (United States)

    Kawashima, N.; Muramatsu, H.; Ueda, M.; Yanagimoto, C.; Miyazawa, M.; Kajiwara, E.

    2012-02-01

    Focusing a femto-second laser (1 mJ/pulse repetition 1 kHz) on a special tape, a strong radiation consisting of the electron beam of ~ 200 keV and X-rays of ~ 6.4 keV (5 %) has been generated. It has been verified that the radiation source is sufficient to kill the tumor cells and the DNA laddering structure in the in-vivo test is obtained. More test implanting the tumor under the skin of mouse and irradiating the laser-generated radiation, we have shown the radiation has a clear powerful therapeutic capability. For about 80 % of mice irradiated, their tumor disappeared. For further clinical test use, a compact laparoscope-type unit mounted on an articulated arm has been constructed and it can generate the necessary amount of the radiation dose.

  2. estimation of background radiation at rivers state university of ...

    African Journals Online (AJOL)

    DJFLEX

    State University of Science and Technology was measured using a specialize digital, radiation meter type, radalert -. 50, which is ... Measurements were carried out within seven working hours of the day and for seven days of the week in each of the five locations ..... Ricke, G., 1996. Detection of light him UV to the sub.

  3. Multiple circumstellar shells and radiation pressure on grains in the outflows from late-type giants

    Science.gov (United States)

    Jura, M.

    1984-01-01

    It is pointed out that mass loss from red giants and supergiants is sometimes as high as 0.0001 solar mass per year. This mass loss represents a major source of new interstellar matter. The present investigation is concerned with the phenomena involved in stellar mass loss, taking into account a comparison of currently available observations with plausible models. The case of the extended circumstellar envelope around IRC +10216 is considered. In observations about mass loss from circumstellar shells, it is sometimes found that the P Cygni profiles are split into two or more sharp, distinct components. The question is considered whether such narrow separate components can be understood in terms of the radiation pressure model. A grain growth model is discussed along with outflow velocity, radiation pressure, and mass loss rates. The models are compared with observations from Alpha Orionis, Mira, and IRC +10216. It is concluded that a hybrid model for the mass loss from some late-type stars seems appropriate. Under certain conditions, outflow speeds of 10 to 20 km/s can be understood.

  4. Radiation resistance of double-type double-sided 3D pixel sensors

    CERN Document Server

    Fernandez, M; Lozano, M; Munoz, F.J; Pellegrini, G; Quirion, D; Rohe, T; Vila, I

    2013-01-01

    The proposed high-luminosity upgrade of the Large Hadron Collider is expected to increase the instantaneous luminosity at the experiments' interaction points by a factor of ten. The vertex detector will be the subsystem most affected by the luminosity increase, raising substantially their occupancy and radiation-induced damage. To preserve the vertex physics performance under these new conditions, current pixel technologies have to be improved. Hybrid pixel sensors with double-sided double-type vertical electrodes (3D sensors) are becoming a mature technology for the detector layers closest to the interaction point due to their intrinsic radiation hardness. In addition, the double-sided implementation of the 3D pixel technology provides some additional technical advantages with respect to the single-sided implementation. For this study, 3D pixel sensors manufactured at the Centro Nacional de Microelectrónica of Barcelona (IMB-CNM) have been bonded to the PSI46 readout chip currently used by the Compact Muon ...

  5. GARUSO - Version 1.0. Uncertainty model for multipath ultrasonic transit time gas flow meters

    Energy Technology Data Exchange (ETDEWEB)

    Lunde, Per; Froeysa, Kjell-Eivind; Vestrheim, Magne

    1997-09-01

    This report describes an uncertainty model for ultrasonic transit time gas flow meters configured with parallel chords, and a PC program, GARUSO Version 1.0, implemented for calculation of the meter`s relative expanded uncertainty. The program, which is based on the theoretical uncertainty model, is used to carry out a simplified and limited uncertainty analysis for a 12`` 4-path meter, where examples of input and output uncertainties are given. The model predicts a relative expanded uncertainty for the meter at a level which further justifies today`s increasing tendency to use this type of instruments for fiscal metering of natural gas. 52 refs., 15 figs., 11 tabs.

  6. Streamlining Smart Meter Data Analytics

    DEFF Research Database (Denmark)

    Liu, Xiufeng; Nielsen, Per Sieverts

    2015-01-01

    -economic metrics such as the geographic information of meters, the information about users and their property, geographic location and others, which make the data management very complex. On the other hand, data-mining and the emerging cloud computing technologies make the collection, management, and analysis...... of the so-called big data possible. This can improve energy management, e.g., help utilities improve the management of energy and services, and help customers save money. As this regard, the paper focuses on building an innovative software solution to streamline smart meter data analytic, aiming at dealing...... with the complexity of data processing and data analytics. The system offers an information integration pipeline to ingest smart meter data; scalable data processing and analytic platform for pre-processing and mining big smart meter data sets; and a web-based portal for visualizing data analytics results. The system...

  7. Smart meters in smart manufacturing

    OpenAIRE

    Martín Rubio, Irene; Florence Sandoval, Antonio; Gonzalez Sanchez, Elena; Andina de la Fuente, Diego

    2016-01-01

    The extent of change in business process and smart manufacturing usage should be taken into account in every energy efficiency project in industries. A significant part of smart metering success depends upon making the business processes more systematic. Smart manufacturing in the dramatically intensified and pervasive application of networked information-based technologies through the manufacturing and supply chain enterprise. There is no doubt that the deployment os smart meters involves ...

  8. Healthcare Energy Metering Guidance (Brochure)

    Energy Technology Data Exchange (ETDEWEB)

    2011-07-01

    This brochure is intended to help facility and energy managers plan and prioritize investments in energy metering. It offers healthcare-specific examples of metering applications, benefits, and steps that other health systems can reproduce. It reflects collaborative input from the U.S. Department of Energy national laboratories and the health system members of the DOE Hospital Energy Alliance's Benchmarking and Measurement Project Team.

  9. Dual type fiber-optic radiation sensor for measuring alpha and beta particles

    Science.gov (United States)

    Shin, Sang Hun; Song, Young Beom; Kim, Mingeon; Kim, Hye Jin; Yoo, Wook Jae; Jang, Kyoung Won; Lee, Bongsoo

    2017-04-01

    In this study, we fabricated a dual type fiber-optic radiation sensor (DFORS) system using a spectroscopic technique to measure alpha and beta particles simultaneously and separately. The DFORS is composed of a sensing probe, a plastic optical fiber (POF), a photomultiplier tube (PMT)-amplifier system, and a multichannel analyzer (MCA). As sensing probes, a ZnS(Ag) film and CaF2(Eu) crystal were used for alpha and beta spectroscopy. And, we measured the alpha and beta energy spectra using the proposed DFORS system to discriminate species of the radioisotopes emitting alpha or beta particle. From the experimental results, we demonstrated that the small-sized, flexible, and insertable DFORS system can measure and discriminate the alpha and beta successfully with the spectral information of each radioisotope.

  10. Shortwave radiative forcing and efficiency of key aerosol types using AERONET data

    Directory of Open Access Journals (Sweden)

    O. E. García

    2012-06-01

    Full Text Available The shortwave radiative forcing (ΔF and the radiative forcing efficiency (ΔFeff of natural and anthropogenic aerosols have been analyzed using estimates of radiation both at the Top (TOA and at the Bottom Of Atmosphere (BOA modeled based on AERONET aerosol retrievals. Six main types of atmospheric aerosols have been compared (desert mineral dust, biomass burning, urban-industrial, continental background, oceanic and free troposphere in similar observational conditions (i.e., for solar zenith angles between 55° and 65° in order to compare the nearly same solar geometry. The instantaneous ΔF averages obtained vary from −122 ± 37 Wm−2 (aerosol optical depth, AOD, at 0.55 μm, 0.85 ± 0.45 at the BOA for the mixture of desert mineral dust and biomass burning aerosols in West Africa and −42 ± 22 Wm−2 (AOD = 0.9 ± 0.5 at the TOA for the pure mineral dust also in this region up to −6 ± 3 Wm−2 and −4 ± 2 Wm−2 (AOD = 0.03 ± 0.02 at the BOA and the TOA, respectively, for free troposphere conditions. This last result may be taken as reference on a global scale. Furthermore, we observe that the more absorbing aerosols are overall more efficient at the BOA in contrast to at the TOA, where they backscatter less solar energy into the space. The analysis of the radiative balance at the TOA shows that, together with the amount of aerosols and their absorptive capacity, it is essential to consider the surface albedo of the region on which they are. Thus, we document that in regions with high surface reflectivity (deserts and snow conditions atmospheric aerosols lead to a warming of the Earth-atmosphere system.

  11. X-ray intensifying screen visible light detection meter.

    Science.gov (United States)

    McLean, D; Eisenhuth, J; Knight, P; Bui, Q

    1997-06-01

    A light meter has been designed and built for the purpose of measuring the light emitted from an intensifying screen during x-ray irradiation. The meter uses a photodiode detector with a minimal drift amplification system. The meter repeatability was better than 0.5% and was found to be linear. A significant x-ray induced signal was recorded during measurement which needed to be subtracted from readings to deduce the intensification screen light output. The energy response of four screen types was subsequently measured.

  12. Analysis of the spatial dose according to the type of radiation source used in multi-bed hospital room

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Dong Gun [Dept. of Nuclear Medicine, Dongnam Institute of Radiological and Medical Sciences Cancer center, Busan (Korea, Republic of); Kim, Jung Hoon [Dept. of Radiological Science, College of Health Sciences, Catholic University of Pusan, Busan (Korea, Republic of); Park, Eun Tae [Dept. of Radiation Oncology, Busan Paik Hospital, Inje University, Busan (Korea, Republic of)

    2017-09-15

    Medical radiation offers significant benefits in diagnosing and treating patients, but it also generates unnecessary radiation exposure to those nearby. Accordingly, the objective of the present study was to analyze spatial dose rate according to types of radiation source term in multi-bed hospital rooms occupied by patients and general public. MCNPX was used for geometric simulation of multi-bed hospital rooms and radiation source terms, while the radiation source terms were established as whole body bone scan patients and imaging using a portable X-ray generator. The results of simulation on whole body bone scan patients showed 3.46 μSv/hr to another patient position, while experimental results on imaging using a portable X-ray generator showed 1.47 × 10{sup -8} μSv/irradiation to another patient position in chest imaging and 2.97 × 10{sup -8} μSv/irradiation to another patient position in abdomen imaging. Multi-bed hospital room, unnecessary radiation generated in the surrounding patients, while legal regulations and systematic measures are needed for radiation exposure in multi-bed hospital rooms that are currently lacking in Korea.

  13. Brazilian multicenter study for the evaluation of patients' satisfaction of blood glucose self-monitoring with BGStar(®) blood glucose meter in insulinized patients with diabetes mellitus type 1 and 2.

    Science.gov (United States)

    Hissa, Miguel Nasser

    2016-01-01

    Diabetes mellitus (DM) is considered a global epidemic, and patient self-management education and support are critical in preventing and reducing the risk of complications. Self-monitoring of blood glucose (SMBG) is essential for care of individuals with DM, helping patients to achieve and maintain target blood glucose levels. The purpose of this study is to compare the satisfaction of insulinized DM patients on SMBG with use of investigational blood glucose meter (BGM) versus their routine device. A national, multicenter, open-label, phase 4 study was conducted on patients with type 1 or 2 DM under insulin therapy regimen, who were asked to use investigational BGM instead of their usual BGM device. The study was performed in 12 centers in Brazil for 12 weeks, with an extension period of 12 weeks. The primary endpoint was to measure the variation on the patients' level of satisfaction with investigational versus routine BGM, between visits, using a Visual Analogue Scale (VAS). Secondary endpoints addressed handling aspects, satisfaction, adherence and level of functionality and safety of investigational BGM. The study included 292 patients (36.6 % DM1 and 63.4 % DM2), mean age 50.9 years old (±17.3 years), 57.5 % females. There was statistically significant improvement in global satisfaction with investigational BGM compared with routine BGM according to VAS [mean VAS score raised from 78.8 mm (SD = 18.0) to 90.8 mm (SD = 12.2) between visits]. After 12 weeks, level of satisfaction with investigational BGM according to questionnaires was superior to routine BGM regardless of age group (p < 0.001), type of DM (p < 0.001) or insulin regimen (p < 0.001). Investigational BGM was also regarded as safe, with 10 patients (3.4 %) reporting a total of 13 adverse events during the study. Levels of satisfaction during SMBG were higher with use of investigational BGM and the device was deemed safe and easy to handle.

  14. Radiation Hydrodynamical Models for Type I Superluminous Supernovae: Constraints on Progenitors and Explosion Mechanisms

    Science.gov (United States)

    Nomoto, Ken&'Ichi; Tolstov, Alexey; Sorokina, Elena; Blinnikov, Sergei; Bersten, Melina; Suzuki, Tomoharu

    2017-11-01

    The physical origin of Type-I (hydrogen-less) superluminous supernovae (SLSNe-I), whose luminosities are 10 to 500 times higher than normal core-collapse supernovae, remains still unknown. Thanks to their brightness, SLSNe-I would be useful probes of distant Universe. For the power source of the light curves of SLSNe-I, radioactive-decays, magnetars, and circumstellar interactions have been proposed, although no definitive conclusions have been reached yet. Since most of light curve studies have been based on simplified semi-analytic models, we have constructed multi-color light curve models by means of detailed radiation hydrodynamical calculations for various mass of stars including very massive ones and large amount of mass loss. We compare the rising time, peak luminosity, width, and decline rate of the model light curves with observations of SLSNe-I and obtain constraints on their progenitors and explosion mechanisms. We particularly pay attention to the recently reported double peaks of the light curves. We discuss how to discriminate three models, relevant models parameters, their evolutionary origins, and implications for the early evolution of the Universe.

  15. The Ozone Layer and Metered Dose Inhalers

    Directory of Open Access Journals (Sweden)

    Louis-Philippe Boulet

    1998-01-01

    Full Text Available The stratospheric ozone layer plays a crucial role in protecting living organisms against ultraviolet radiation. Chlorofluorocarbons (CFC contained in metered-dose inhalers (MDIs contribute to ozone depletion and in accordance with the Montreal Protocol on Substances That Deplete the Ozone Layer established 10 years ago, phase-out strageies have been developed worldwide for this category of agents. Alternatives to CFC-containing inhalers have been developed, such as powder inhalers and those using hydrofluoroalkanes (HFAs as propellants, which have been shown to be as safe and effective as CFC-containing inhalers and even offer interesting advantages over older inhalers. The transition to non-CFC MDIs requires a major effort to make the new products available and to ensure adequate comparision with the previous ones. It also requires a harmonization of actions taken by industry, government, licencing bodies and patients or health professional associations to ensure adequate information and education to the public and respiratory care providers.

  16. Automated monitoring of milk meters

    NARCIS (Netherlands)

    Mol, de R.M.; Andre, G.

    2009-01-01

    Automated monitoring might be an alternative for periodic checking of electronic milk meters. A computer model based on Dynamic Linear Modelling (DLM) has been developed for this purpose. Two situations are distinguished: more milking stands in the milking parlour and only one milking stand in the

  17. MULTICHANNEL DISTRIBUTION METER: A VERITABLE ...

    African Journals Online (AJOL)

    eobe

    replaced by their digital counterparts, which come with the capability of automatic disconnection. Yet, in every other ... neutral lines to detect pilferages in digital meters, while a light emitting diode (LED), a light dependent ..... Conditions in a Developing Economy”, Nigerian. Journal of Technology, Vol. 6 No. 1 September 1982.

  18. Perceptions of Radiation Oncologists and Urologists on Sources and Type of Evidence to Inform Prostate Cancer Treatment Decisions

    Energy Technology Data Exchange (ETDEWEB)

    Han, Leona C. [Division of Health Care Policy and Research, Mayo Clinic, Rochester, Minnesota (United States); Delpe, Sophia [Department of Urology, Yale University, New Haven, Connecticut (United States); Shah, Nilay D. [Division of Health Care Policy and Research, Mayo Clinic, Rochester, Minnesota (United States); Ziegenfuss, Jeanette Y. [HealthPartners, Minneapolis, Minnesota (United States); Tilburt, Jon C. [Knowledge and Evaluation Research Unit, Mayo Clinic, Rochester, Minnesota (United States); Biomedical Ethics Program, Mayo Clinic, Rochester, Minnesota (United States); Division of General Internal Medicine, Mayo Clinic, Rochester, Minnesota (United States); Karnes, R. Jeffrey [Department of Urology, Mayo Clinic, Rochester, Minnesota (United States); Nguyen, Paul L. [Division of Radiation Oncology, Dana-Farber Cancer Institute, Brigham and Women' s Hospital, Harvard Medical School, Boston, Massachusetts (United States); Gross, Cary P. [Cancer Outcomes and Public Policy Effectiveness Research Center, Yale University, New Haven, Connecticut (United States); Department of Internal Medicine, Yale University, New Haven, Connecticut (United States); Yu, James B. [Cancer Outcomes and Public Policy Effectiveness Research Center, Yale University, New Haven, Connecticut (United States); Department of Radiation Oncology, Yale University, New Haven, Connecticut (United States); Trinh, Quoc-Dien [Division of Urology, Brigham and Women' s Hospital, Harvard University, Boston, Massachusetts (United States); Sun, Maxine [Cancer Prognostics and Health Outcomes, University of Montreal Health Center, Montreal, QC (Canada); Ranasinghe, Weranja K.B. [Division of Urology, Alfred Hospital, Prahran, Melbourne, Victoria (Australia); Kim, Simon P., E-mail: simkim@me.com [Department of Urology, Yale University, New Haven, Connecticut (United States); Cancer Outcomes and Public Policy Effectiveness Research Center, Yale University, New Haven, Connecticut (United States)

    2014-06-01

    Purpose: To perform a national survey of radiation oncologists and urologists about the type of resources used and the level of evidence needed to change clinical practice in localized prostate cancer. Methods and Materials: From a random sample, 1422 physicians were mailed a survey assessing the types of information used and what level of evidence could alter their clinical practice in prostate cancer. Multivariable logistic regression models were used to identify differences in physician characteristics for each outcome. Results: Survey response rates were similar for radiation oncologists and urologists (44% vs 46%; P=.46). Specialty-specific journals represented the most commonly used resource for informing the clinical practice for radiation oncologists (65%) and urologists (70%). Relative to radiation oncologists, urologists were less likely to report utilizing top-tier medical journals (25% vs 39%; adjusted odds ratio [OR] 0.50; P=.01) or cancer journals (22% vs 51%; adjusted OR 0.50; P<.001) but more likely to rely on clinical guidelines (46% vs 38%; adjusted OR 1.6; P=.006). Both radiation oncologists and urologists most commonly reported large randomized, clinical trials as the level of evidence to change treatment recommendations for localized prostate cancer (85% vs 77%; P=.009). Conclusions: Both specialties rely on their own specialty-specific journals and view randomized, clinical trials as the level of evidence needed to change clinical practice. Our study provides a context on meaningful ways of disseminating evidence for localized prostate cancer.

  19. PELATIHAN LARI INTERVAL 4 X 50 METER DI PANTAI BERPASIR LEBIH MENINGKATKAN KECEPATAN LARI 100 METER DARIPADA PELATIHAN LARI INTERVAL 4 X 50 METER DI LAPANGAN PADA SISWA KELAS XSMK N KAKULUK MESAK NTT.

    OpenAIRE

    Benediktus Nahak; Alex Pangkahila; Susy Purnawati

    2014-01-01

    The speed is one of the biomotoriccomponents which dominantin the run race100 meters. 100 meters run is part of athletics which has a short duration, highintensity and anaerobic systems develop. The purpose of this study was todetermine the increasing of 100 meter run speed, therefore this research is anexperimental study was conducted in SMK N Kakulukmesak Belu regency NTT,for 6 months from March - May 2014, with the frequency of exercise 3 times aweek. This study uses two types of training,...

  20. Smart metering. Conformance tests for electricity meters; Smart Metering. Konformitaetstests an Stromzaehlern

    Energy Technology Data Exchange (ETDEWEB)

    Bormann, Matthias; Pongratz, Siegfried [VDE Pruef- und Zertifizierungsinstitut, Offenbach (Germany)

    2012-07-01

    Introduction of communication technologies into today's energy network enables the interworking between the domains of smart metering, smart grid, smart home and e-mobility as well as the creation and provisioning of new innovative services such as efficient load adjustment. Due to this convergence the new energy networks are becoming increasingly complex. Ensuring the interworking between all network elements (e.g. electricity meters, gateways) in these smart energy networks is of utmost importance. To this end conformance and interoperability tests have to be defined to ensure that services work as expected. (orig.)

  1. Cloud radiative effect, cloud fraction and cloud type at two stations in Switzerland using hemispherical sky cameras

    Science.gov (United States)

    Aebi, Christine; Gröbner, Julian; Kämpfer, Niklaus; Vuilleumier, Laurent

    2017-11-01

    The current study analyses the cloud radiative effect during the daytime depending on cloud fraction and cloud type at two stations in Switzerland over a time period of 3 to 5 years. Information on fractional cloud coverage and cloud type is retrieved from images taken by visible all-sky cameras. Cloud-base height (CBH) data are retrieved from a ceilometer and integrated water vapour (IWV) data from GPS measurements. The longwave cloud radiative effect (LCE) for low-level clouds and a cloud coverage of 8 oktas has a median value between 59 and 72 Wm-2. For mid- and high-level clouds the LCE is significantly lower. It is shown that the fractional cloud coverage, the CBH and IWV all have an influence on the magnitude of the LCE. These observed dependences have also been modelled with the radiative transfer model MODTRAN5. The relative values of the shortwave cloud radiative effect (SCErel) for low-level clouds and a cloud coverage of 8 oktas are between -90 and -62 %. Also here the higher the cloud is, the less negative the SCErel values are. In cases in which the measured direct radiation value is below the threshold of 120 Wm-2 (occulted sun) the SCErel decreases substantially, while cases in which the measured direct radiation value is larger than 120 Wm-2 (visible sun) lead to a SCErel of around 0 %. In 14 and 10 % of the cases in Davos and Payerne respectively a cloud enhancement has been observed with a maximum in the cloud class cirrocumulus-altocumulus at both stations. The calculated median total cloud radiative effect (TCE) values are negative for almost all cloud classes and cloud coverages.

  2. Parallel evolution of a type IV secretion system in radiating lineages of the host-restricted bacterial pathogen Bartonella.

    Science.gov (United States)

    Engel, Philipp; Salzburger, Walter; Liesch, Marius; Chang, Chao-Chin; Maruyama, Soichi; Lanz, Christa; Calteau, Alexandra; Lajus, Aurélie; Médigue, Claudine; Schuster, Stephan C; Dehio, Christoph

    2011-02-10

    Adaptive radiation is the rapid origination of multiple species from a single ancestor as the result of concurrent adaptation to disparate environments. This fundamental evolutionary process is considered to be responsible for the genesis of a great portion of the diversity of life. Bacteria have evolved enormous biological diversity by exploiting an exceptional range of environments, yet diversification of bacteria via adaptive radiation has been documented in a few cases only and the underlying molecular mechanisms are largely unknown. Here we show a compelling example of adaptive radiation in pathogenic bacteria and reveal their genetic basis. Our evolutionary genomic analyses of the α-proteobacterial genus Bartonella uncover two parallel adaptive radiations within these host-restricted mammalian pathogens. We identify a horizontally-acquired protein secretion system, which has evolved to target specific bacterial effector proteins into host cells as the evolutionary key innovation triggering these parallel adaptive radiations. We show that the functional versatility and adaptive potential of the VirB type IV secretion system (T4SS), and thereby translocated Bartonella effector proteins (Beps), evolved in parallel in the two lineages prior to their radiations. Independent chromosomal fixation of the virB operon and consecutive rounds of lineage-specific bep gene duplications followed by their functional diversification characterize these parallel evolutionary trajectories. Whereas most Beps maintained their ancestral domain constitution, strikingly, a novel type of effector protein emerged convergently in both lineages. This resulted in similar arrays of host cell-targeted effector proteins in the two lineages of Bartonella as the basis of their independent radiation. The parallel molecular evolution of the VirB/Bep system displays a striking example of a key innovation involved in independent adaptive processes and the emergence of bacterial pathogens

  3. Parallel evolution of a type IV secretion system in radiating lineages of the host-restricted bacterial pathogen Bartonella.

    Directory of Open Access Journals (Sweden)

    Philipp Engel

    2011-02-01

    Full Text Available Adaptive radiation is the rapid origination of multiple species from a single ancestor as the result of concurrent adaptation to disparate environments. This fundamental evolutionary process is considered to be responsible for the genesis of a great portion of the diversity of life. Bacteria have evolved enormous biological diversity by exploiting an exceptional range of environments, yet diversification of bacteria via adaptive radiation has been documented in a few cases only and the underlying molecular mechanisms are largely unknown. Here we show a compelling example of adaptive radiation in pathogenic bacteria and reveal their genetic basis. Our evolutionary genomic analyses of the α-proteobacterial genus Bartonella uncover two parallel adaptive radiations within these host-restricted mammalian pathogens. We identify a horizontally-acquired protein secretion system, which has evolved to target specific bacterial effector proteins into host cells as the evolutionary key innovation triggering these parallel adaptive radiations. We show that the functional versatility and adaptive potential of the VirB type IV secretion system (T4SS, and thereby translocated Bartonella effector proteins (Beps, evolved in parallel in the two lineages prior to their radiations. Independent chromosomal fixation of the virB operon and consecutive rounds of lineage-specific bep gene duplications followed by their functional diversification characterize these parallel evolutionary trajectories. Whereas most Beps maintained their ancestral domain constitution, strikingly, a novel type of effector protein emerged convergently in both lineages. This resulted in similar arrays of host cell-targeted effector proteins in the two lineages of Bartonella as the basis of their independent radiation. The parallel molecular evolution of the VirB/Bep system displays a striking example of a key innovation involved in independent adaptive processes and the emergence of bacterial

  4. Geometrical correction factors for heat flux meters

    Science.gov (United States)

    Baumeister, K. J.; Papell, S. S.

    1974-01-01

    General formulas are derived for determining gage averaging errors of strip-type heat flux meters used in the measurement of one-dimensional heat flux distributions. The local averaging error e(x) is defined as the difference between the measured value of the heat flux and the local value which occurs at the center of the gage. In terms of e(x), a correction procedure is presented which allows a better estimate for the true value of the local heat flux. For many practical problems, it is possible to use relatively large gages to obtain acceptable heat flux measurements.

  5. Space-type radiation induces multimodal responses in the mouse gut microbiome and metabolome.

    Science.gov (United States)

    Casero, David; Gill, Kirandeep; Sridharan, Vijayalakshmi; Koturbash, Igor; Nelson, Gregory; Hauer-Jensen, Martin; Boerma, Marjan; Braun, Jonathan; Cheema, Amrita K

    2017-08-18

    Space travel is associated with continuous low dose rate exposure to high linear energy transfer (LET) radiation. Pathophysiological manifestations after low dose radiation exposure are strongly influenced by non-cytocidal radiation effects, including changes in the microbiome and host gene expression. Although the importance of the gut microbiome in the maintenance of human health is well established, little is known about the role of radiation in altering the microbiome during deep-space travel. Using a mouse model for exposure to high LET radiation, we observed substantial changes in the composition and functional potential of the gut microbiome. These were accompanied by changes in the abundance of multiple metabolites, which were related to the enzymatic activity of the predicted metagenome by means of metabolic network modeling. There was a complex dynamic in microbial and metabolic composition at different radiation doses, suggestive of transient, dose-dependent interactions between microbial ecology and signals from the host's cellular damage repair processes. The observed radiation-induced changes in microbiota diversity and composition were analyzed at the functional level. A constitutive change in activity was found for several pathways dominated by microbiome-specific enzymatic reactions like carbohydrate digestion and absorption and lipopolysaccharide biosynthesis, while the activity in other radiation-responsive pathways like phosphatidylinositol signaling could be linked to dose-dependent changes in the abundance of specific taxa. The implication of microbiome-mediated pathophysiology after low dose ionizing radiation may be an unappreciated biologic hazard of space travel and deserves experimental validation. This study provides a conceptual and analytical basis of further investigations to increase our understanding of the chronic effects of space radiation on human health, and points to potential new targets for intervention in adverse radiation

  6. PRESCILA: a new, lightweight neutron rem meter.

    Science.gov (United States)

    Olsher, Richard H; Seagraves, David T; Eisele, Shawna L; Bjork, Christopher W; Martinez, William A; Romero, Leonard L; Mallett, Michael W; Duran, Michael A; Hurlbut, Charles R

    2004-06-01

    Conventional neutron rem meters currently in use are based on 1960's technology that relies on a large neutron moderator assembly surrounding a thermal detector to achieve a rem-like response function over a limited energy range. Such rem meters present an ergonomic challenge, being heavy and bulky, and have caused injuries during radiation protection surveys. Another defect of traditional rem meters is a poor high-energy response above 10 MeV, which makes them unsuitable for applications at high-energy accelerator facilities. Proton Recoil Scintillator-Los Alamos (PRESCILA) was developed as a low-weight (2 kg) alternative capable of extended energy response, high sensitivity, and moderate gamma rejection. An array of ZnS(Ag) based scintillators is located inside and around a Lucite light guide, which couples the scintillation light to a sideview bialkali photomultiplier tube. The use of both fast and thermal scintillators allows the energy response function to be optimized for a wide range of operational spectra. The light guide and the borated polyethylene frame provide moderation for the thermal scintillator element. The scintillators represent greatly improved versions of the Hornyak and Stedman designs from the 1950's, and were developed in collaboration with Eljen Technology. The inherent pulse height advantage of proton recoils over electron tracks in the phosphor grains eliminates the need for pulse shape discrimination and makes it possible to use the PRESCILA probe with standard pulse height discrimination provided by off-the-shelf health physics counters. PRESCILA prototype probes have been extensively tested at both Los Alamos and the German Bureau of Standards, Physikalisch-Technische Bundesanstalt. Test results are presented for energy response, directional dependence, linearity, sensitivity, and gamma rejection. Initial field tests have been conducted at Los Alamos and these results are also given. It is concluded that PRESCILA offers a viable

  7. Adding chemo after radiation treatment improves survival for adults with a type of brain tumor

    Science.gov (United States)

    Adults with low-grade gliomas, a form of brain tumor, who received chemotherapy following completion of radiation therapy lived longer than patients who received radiation therapy alone, according to long-term follow-up results from a NIH-supported random

  8. Evidence of Dopant Type-Inversion and Other Radiation Damage Effects of the CDF Silicon Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Martinez-Ballarin, Roberto [Univ. of the Basque Country, Leioa (Spain)

    2010-06-01

    The aim of this document is to study the effect of radiation damage on the silicon sensors. The reflection of the effect of radiation can be observed in two fundamental parameters of the detector: the bias current and the bias voltage. The leakage current directly affects the noise, while the bias voltage is required to collect the maximum signal deposited by the charged particle.

  9. Radiation-induced cell transformation: transformation efficiencies of different types of ionizing radiation and molecular changes in radiation transformants and tumor cell lines.

    OpenAIRE

    Hieber, L.; Trutschler, K; Smida, J.; Wachsmann, M; Ponsel, G.; Kellerer, Albrecht M.

    1990-01-01

    This study aims to compare the efficiencies of 5.4 keV soft X-rays, alpha-particles, and gamma-rays in transforming C3H 10T1/2 cells and to assess the sequence of cellular and molecular changes during the process of radiation-induced transformation of Syrian hamster embryo (SHE) cells. The somewhat more densely ionizing soft X-rays are more effective than gamma-rays both for cell inactivation and cell transformation. The relative biological effectiveness (RBE) appears to be independent of dos...

  10. Two-dimensional radiation hydrodynamics simulations of superluminous interacting supernovae of Type IIn

    Science.gov (United States)

    Vlasis, Alkiviadis; Dessart, Luc; Audit, Edouard

    2016-05-01

    Some interacting supernovae (SNe) of Type IIn show a sizeable continuum polarization suggestive of a large-scale asymmetry in the circumstellar medium (CSM) and/or the SN ejecta. Here, we extend the recent work of Dessart et al. on superluminous SNe IIn and perform axially-symmetric (I.e. 2D) multigroup radiation hydrodynamics simulations to explore the impact of an imposed large-scale density asymmetry. When the CSM is asymmetric, the latitudinal variation of the radial optical depth τ introduces a strong flux redistribution from the higher density CSM regions, where the shock luminosity is larger, towards the lower density CSM regions where photons escape more freely - this redistribution ceases when τ ≲ 1. Along directions where the CSM density is larger, the shock deceleration is stronger and its progression slower, producing a non-spherical cold-dense shell (CDS). For an oblate CSM density distribution, the photosphere (CDS) has an oblate (prolate) morphology when τ ≳ 1. When the CSM is symmetric and the ejecta asymmetric, the flux redistribution within the CSM now tends to damp the latitudinal variation of the luminosity at the shock. It then requires a larger ejecta asymmetry to produce a sizeable latitudinal variation in the emergent flux. When the interaction is between a SN ejecta and a relic disc, the luminosity boost at early times scales with the disc opening angle - forming a superluminous SN IIn this way requires an unrealistically thick disc. In contrast, interaction with a disc of modest thickness/mass can yield a power that rivals radioactive decay of a standard SN II at nebular times.

  11. Effect of cloud cover and surface type on earth's radiation budget derived from the first year of ERBE data

    Science.gov (United States)

    Gibson, G. G.; Denn, F. M.; Young, D. F.; Harrison, E. F.; Minnis, P.; Barkstrom, B. R.

    1990-01-01

    One year of ERBE data is analyzed for variations in outgoing LW and absorbed solar flux. Differences in land and ocean radiation budgets as well as differences between clear-sky and total scenes, including clouds, are studied. The variation of monthly average radiative parameters is examined for February 1985 through January 1986 for selected study regions and on zonal and global scales. ERBE results show significant seasonal variations in both outgoing LW and absorbed SW flux, and a pronounced difference between oceanic and continental surfaces. The main factors determining cloud radiative forcing in a given region are solar insolation, cloud amount, cloud type, and surface properties. The strongest effects of clouds are found in the midlatitude storm tracks over the oceans. Over much of the globe, LW warming is balanced by SW cooling. The annual-global average net cloud forcing shows that clouds have a net cooling effect on the earth for the year.

  12. Identification of aerosol types over Indo-Gangetic Basin: implications to optical properties and associated radiative forcing.

    Science.gov (United States)

    Tiwari, S; Srivastava, A K; Singh, A K; Singh, Sachchidanand

    2015-08-01

    The aerosols in the Indo-Gangetic Basin (IGB) are a mixture of sulfate, dust, black carbon, and other soluble and insoluble components. It is a challenge not only to identify these various aerosol types, but also to assess the optical and radiative implications of these components. In the present study, appropriate thresholds for fine-mode fraction and single-scattering albedo have been used to first identify the aerosol types over IGB. Four major aerosol types may be identified as polluted dust (PD), polluted continental (PC), black carbon-enriched (BCE), and organic carbon-enriched (OCE). Further, the implications of these different types of aerosols on optical properties and radiative forcing have been studied. The aerosol products derived from CIMEL sun/sky radiometer measurements, deployed under Aerosol Robotic Network program of NASA, USA were used from four different sites Karachi, Lahore, Jaipur, and Kanpur, spread over Pakistan and Northern India. PD is the most dominant aerosol type at Karachi and Jaipur, contributing more than 50% of all the aerosol types. OCE, on the other hand, contributes only about 12-15% at all the stations except at Kanpur where its contribution is ∼38%. The spectral dependence of AOD was relatively low for PD aerosol type, with the lowest AE values (aerosol types, with the highest AE values (>1.0). SSA was found to be the highest for OCE (>0.9) and the lowest for BCE (aerosols, with drastically different spectral variability. The direct aerosol radiative forcing at the surface and in the atmosphere was found to be the maximum at Lahore among all the four stations in the IGB.

  13. Federal Building Metering Guidance (per 42 U.S.C. 8253(e), Metering of Energy Use)

    Energy Technology Data Exchange (ETDEWEB)

    None

    2014-11-01

    Guidance defines which federal buildings are appropriate to meter, provides metering prioritization recommendations for agencies with limited resources, and discusses the requirement for agencies to submit metering implementation plans to the U.S. Department of Energy.

  14. 77 FR 40586 - Draft NIST Interagency Report (NISTIR) 7823, Advanced Metering Infrastructure Smart Meter...

    Science.gov (United States)

    2012-07-10

    ... 7823 includes numerous stakeholders in the Smart Grid space, particularly customers, Smart Meter... National Institute of Standards and Technology Draft NIST Interagency Report (NISTIR) 7823, Advanced Metering Infrastructure Smart Meter Upgradeability Test Framework; Request for Comments AGENCY: National...

  15. Smart Metering System for Microgrids

    OpenAIRE

    Palacios-Garcia, Emilio; Guan, Yajuan; Savaghebi, Mehdi; Quintero, Juan Carlos Vasquez; Guerrero, Josep M.; Moreno-Munoz, Antonio; Ipsen, Brian S.

    2015-01-01

    Smart meters are the cornerstone in the new conception of the electrical network or Smart Grid (SG), providing detailed information about users' energy consumption and allowing the suppliers to remotely collect data for billing. Nevertheless, their features are not only useful for the energy suppliers, but they can also play a big role in the control of the Microgrid since the recorded power and energy profiles can be integrated in energy management systems (EMS). In addition, basic power qua...

  16. Extremely frequency-widened terahertz wave generation using Cherenkov-type radiation

    National Research Council Canada - National Science Library

    Koji Suizu; Kaoru Koketsu; Takayuki Shibuya; Toshihiro Tsutsui; Takuya Akiba; Kodo Kawase

    2009-01-01

    .... The fact limits efficient and wide tunable THz-wave generation. Here, we show that Cherenkov radiation with waveguide structure is an effective strategy for achieving efficient and extremely wide tunable THz-wave source...

  17. On the effect of different aerosol types on surface solar radiation levels over the region of Eastern Mediterranean

    Science.gov (United States)

    Alexandri, Georgia; Georgoulias, Aristeidis K.; Kourtidis, Konstantinos; Meleti, Charikleia; Balis, Dimitris

    2014-05-01

    In this work, we examine the direct effect of different aerosol types on the surface solar radiation (SSR) levels in the region of Eastern Mediterranean. Simulations with the Santa Barbara DISORT Atmospheric Radiative Transfer (SBDART) model were performed using ground and satellite-based data as input. An IDL tool that "feeds" SBDART with the appropriate input data was developed allowing us to simulate SSR with a time step of 1 hour. Level-2 aerosol optical depth, cloud optical depth, cloud fraction, effective droplet radius, cloud top pressure, precipitable water and surface albedo data from MODIS, as well as ozone total column data from Earth Probe TOMS and OMI satellite sensors, coarse resolution cloud data from the ISCCP and single scattering albedo, asymmetry factor and Angström exponent sunphotometric data from the AERONET are used in our radiative transfer simulations. Simulations are performed over selected spots within Eastern Mediterranean for clear, liquid cloud and ice cloud covered skies and for different aerosol types (maritime, dust, anthropogenic, fine-mode natural). The optical properties of aerosols were determined using a combination of satellite, ground-based, model and reanalysis products. The aerosol direct radiative effect is defined as the difference between simulations done with and without the presence of aerosols. This research has been financed by EPAN II and PEP under the national action "Bilateral, multilateral and regional R&T cooperations" (AEROVIS Sino-Greek project).

  18. The synthesis of a new type adsorbent for the removal of toxic gas by radiation-induced graft polymerization

    Science.gov (United States)

    Okamoto, Jiro; Sugo, Takanobu; Fujiwara, Kunio; Sekiguchi, Hideaki

    A new type of adsorbent containing sulfulic acid group for the removal of ammonia gas was synthesized by radiation-induced graft polymerization of styrene onto fibrous and nonwoven type polypropylene followed by sulufonation with chlorosulfonic acid. The rate of the adsorption of ammonia gas by H-type adsorbent is independent of the ion-exchange capacity. The amount of ammonia gas adsorbed by the chemical adsorption was dependent on the ion-exchange capacity of H-type fibrous adsorbent and was kept constant value in spite of the equilibrium pressure of ammonia gas. Cu(II)- and Ni(II)-types fibrous adsorbent were prepared by the ion exchange reaction of Na-type fibrous adsorbent with metal nitrate solutions. Although, the rate of adsorption of ammonia gas by metal-type fibrous adsorbent is lower than that of H-type adsorbent, the amount of ammonia gas adsorbed increase compared to H-type adsorbent with the same ion exchange capacity. It was related to the highest coordination number of metal ion. The ratio of the number of ammonia molecules adsorbed chemically and the number of metal ion adsorbed in fibrous adsorbent was 4 for Cu-type and 6 for Ni-type fibrous adsorbent, respectivelly.

  19. Handheld Multi-Gas Meters Assessment Report

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Gustavious [Brigham Young Univ., Provo, UT (United States); Wald-Hopkins, Mark David [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Obrey, Stephen J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Akhadov, Valida Dushdurova [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-06-27

    Handheld multi-gas meters (MGMs) are equipped with sensors to monitor oxygen (O2) levels and additional sensors to detect the presence of combustible or toxic gases in the environment. This report is limited to operational response-type MGMs that include at least four different sensors. These sensors can vary by type and by the monitored chemical. In real time, the sensors report the concentration of monitored gases in the atmosphere near the MGM. In April 2016 the System Assessment and Validation for Emergency Responders (SAVER) Program conducted an operationally-oriented assessment of MGMs. Five MGMs were assessed by emergency responders. The criteria and scenarios used in this assessment were derived from the results of a focus group of emergency responders with experience in using MGMs. The assessment addressed 16 evaluation criteria in four SAVER categories: Usability, Capability, Maintainability, and Deployability.

  20. 16 CFR 1209.8 - Procedure for calibration of radiation instrumentation.

    Science.gov (United States)

    2010-01-01

    ... radiation pyrometer. Repeat for each temperature. (b) Total heat flux meter. The total flux meter shall be... meter. This latter calibration shall make use of the radiant panel tester as the heat source... maintain a dedicated calibrated reference flux meter against which one or more working flux meters can be...

  1. Capacitive level meter for liquid hydrogen

    OpenAIRE

    Matsumoto, Koichi; Sobue, Masamitsu; Asamoto, Kai; Nishimura, Yuta; Abe, Satoshi; Numazawa, Takenori

    2011-01-01

    A capacitive level meter working at low temperatures was made to use in magnetic refrigerator for hydrogen liquefaction. The liquid level was measured from the capacitance between parallel electrodes immersed in the liquid. The meter was tested for liquid nitrogen, hydrogen, and helium. The operation was successful using an AC capacitance bridge. The estimated sensitivity of the meter is better than 0.2 mm for liquid hydrogen. The meter also worked with pressurized hydrogen. © 2010.

  2. Ionizing radiation measurements and assay of corresponding dose

    African Journals Online (AJOL)

    PUBLICATIONS1

    Nuclear Radiation Meters and Global Positioning System. The survey meters were held ... process release radiation to the environment. (IAEA, 2004). ..... Energy. DE-AC06-76RLO 1830. United Nations Scientific Committee on the. Effects of Atomic Radiation. (UNSCEAR). (2001). Hereditary effects of radiation. Report to the ...

  3. Performance of the tariffs of a single-phase electric energy meter, type electronic, operating with non-linear loads; Desempenho tarifario do medidor monofasico de energia eletrica do tipo eletronico operando com cargas nao-lineares

    Energy Technology Data Exchange (ETDEWEB)

    Santos, G.B.; Pinheiro Neto, D.; Lisita, L.R.; Machado, P.C.M.; Oliveira, J.V.M. [Universidade Federal de Goias (UFG), Goiania, GO (Brazil). Escola de Engenharia Eletrica e de Computacao], Emails: guilhermebsantos@gmail.com, daywes@gmail.com, lrlisi-ta@gmail.com, pcesar@eee.ufg.br, joao.eee@gmail.com

    2009-07-01

    This paper analyzes the behavior of a electronic meter of single-phase in the laboratory when it is subjected to a environment with linear loads and nonlinear loads kind residential and commercial. It differs from correlated studies mainly for making use of real loads encountered in day-to-day, rather than as sources of electronic loads how has been observed in the state of the art. The comparison of results is made based on high precision energy pattern developed by virtual instrumentation means.

  4. Radiation Induced Grafting of Acrylate onto Waste Rubber: The Effect of Monomer Type

    Directory of Open Access Journals (Sweden)

    Shirajuddin Siti Salwa M.

    2017-01-01

    Full Text Available The effect of three different acrylate group monomers, namely n-butyl acrylate, methacrylic acid and tripropylene glycol diacrylate of radiation induced grafting onto waste rubber was studied. The electron beam accelerator operated at voltage of 2MeV was used to irradiate the waste rubber at 10 kGy and 100 kGy absorbed radiation dose, respectively. The formation of grafting was observed from the increase in the grafting yield and confirmed by Transformed Infra-Red Spectroscopy results. According to the result obtained, only tripropylene glycol diacrylate was selected to graft onto waste rubber. The carbonyl bond from acrylate groups was seen at 1726 cm-1 band which confirmed the presence of TPGDA in the polymer matrix. This indicates the successful preparation of the TPGDA-grafted waste rubber via radiation induced grafting techniques.

  5. Radiation from Rocket Exhaust Plumes. Part 1; Inhomogeneous Radiant Heat Transfer from Saturn Type Rocket Exhaust Plumes

    Science.gov (United States)

    Huffaker, Robert M.; Carlson, Donald J.

    1966-01-01

    A radiant heat transfer computer program has been developed by R-AERO-A to calculate radiation from inhomogeneous gases prevalent in Saturn-type exhaust plumes. The radiating species considered in this computer program are water vapor, carbon dioxide, carbon monoxide and carbon particles. The infrared spectral absorption characteristics of these species have been determined under NASA contract. Band model parameters have been used to represent the infrared spectral absorption coefficients over 25 cm-I increments. A modified Curtis-Goodson approximation is used in the inhomogeneous heat transfer calculation. This has been shown to give satisfactory results over the temperature and pressure range of interest in Saturn exhaust plumes. Results are shown for the Saturn-type engines for specific flow field assumptions. Some comparison with experimental spectroscopic data will also be presented. The effect of wavelength increment, field of view, and distance increment along the line of sight on the heat transfer will be discussed. Computer techniques for minimum computer time in calculating radiation from a three-dimensional flow field will also be outlined.

  6. Multitasking metering enhances generation, transmission operations

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, E.

    2008-11-15

    The Dairyland Power Cooperative (DPC) which operates from La Crosse, Wisconsin has the capacity to generate and transmit 1000 MW of power to 25 member cooperatives and 20 municipalities who serve over 500,000 customers. When DPC was experiencing diminished service within its analog cellular-based data communications system, it was presented with an opportunity to install a new automated telecommunications system that would provide secure collection of meter readings from all of its substations. DPC decided to evaluate an advanced multifunctional digital meter from Schweitzer Engineering Laboratories (SEL). The SEL-734 Revenue Metering System offers complete instantaneous metering functions, including voltages, currents, power, energy and power factor. Other capabilities include predictive demand, time-of-use metering, automatic voltage monitoring, harmonics metering and synchrophasor measurement. From a metering perspective, DPC wanted to perform daily load profiles and interval-by-interval metering of their delivery points for billing purposes. They also wanted to provide real-time monitoring of electricity being delivered for both generation and transmission purposes and to make that information available to a distribution SCADA system for their members. The SEL-734 Revenue Meter was well suited to those needs. The SEL-734 provides very high-accuracy energy metering, load profile data collection, instantaneous power measurements, power quality monitoring, and communicates simultaneously over a modem, serial ports, and wide area networks (WAN). The meter is backed with a ten-year warranty as well as field support engineers. 5 figs.

  7. Discussion series on PURPA related topics: metering

    Energy Technology Data Exchange (ETDEWEB)

    Sturgeon, J I

    1980-08-01

    Time-differentiated metering of electricity consumption and demand is required in both rate-structure experimentation and the implementation of most time-of-use rate designs. Time-differentiated metering takes three major forms: multi-register watthour meters, magnetic-tape recording meters, and remote automatic meter-reading systems. The majority of projects selected magnetic-tape meters for their flexibility with respect to rate structure, load-survey capabilities, and ready availability. The small-scale, experimental nature of the projects reduced the significance of the large difference in per-unit cost and operational/maintenance complexity between this form of metering and the multi-register form. Magnetic-tape meters are not likely candidates for system-wide implementation of time-differentiated metering. Automatic remote-meter-reading systems were not adequately available during the project years; those projects attempting to use these were unable to bring them to full operational status before project termination, due to the many problems of design, quality control, and equipment acquisition encountered. Delays in acquisition and problems of quality control also followed the selection of magnetic-tape meters and multi-register meters by a number of the projects. Though less complex than automatic remote-reading systems, these technologies are still new and more complex than standard watthour metering. Thus, both equipment vendors and utilities encountered numerous problems in getting properly functioning meters to the service entrances on time. A variety of factors contributed to installation delays, including unforeseen space limitations, incompatible wiring, problems of task organization, and customer reluctance.

  8. Electromagnetic malfunction of semiconductor-type electronic personal dosimeters caused by access control systems for radiation facilities.

    Science.gov (United States)

    Deji, Shizuhiko; Ito, Shigeki; Ariga, Eiji; Mori, Kazuyuki; Hirota, Masahiro; Saze, Takuya; Nishizawa, Kunihide

    2006-08-01

    High frequency electromagnetic fields in the 120 kHz band emitted from card readers for access control systems in radiation control areas cause abnormally high and erroneous indicated dose readings on semiconductor-type electronic personal dosimeters (SEPDs). All SEPDs malfunctioned but recovered their normal performance by resetting after the exposure ceased. The minimum distances required to prevent electromagnetic interference varied from 5.0 to 38.0 cm. The electric and magnetic immunity levels ranged from 35.1 to 267.6 V m(-1) and from 1.0 to 16.6 A m(-1), respectively. Electromagnetic immunity levels of SEPDs should be strengthened from the standpoint of radiation protection.

  9. Effect of the Aerosol Type Selection for the Retrieval of Shortwave Ground Net Radiation: Case Study Using Landsat 8 Data

    Directory of Open Access Journals (Sweden)

    Cristiana Bassani

    2016-08-01

    Full Text Available This paper discusses the aerosol radiative effects involved in the accuracy of shortwave net radiation, R n . s w , with s w ∈ (400–900 nm, retrieved by the Operational Land Imager (OLI, the new generation sensor of the Landsat mission. Net radiation is a key parameter for the energy exchange between the land and atmosphere; thus, R n . s w retrieval from space is under investigation by exploiting the increased spatial resolution of the visible and near-infrared OLI data. We adopted the latest version of the Second Simulation of a Satellite Signal in the Solar Spectrum (6SV atmospheric radiative transfer model implemented in the atmospheric correction algorithm (OLI Atmospherically-Corrected Reflectance Imagery (OLI@CRI developed specifically for OLI data. The values of R n . s w were obtained by varying the microphysical properties of the aerosol during the OLI@CRI retrieval of both the OLI surface reflectance, ρ p x l o l i , and the incoming solar irradiance at the surface. The analysis of the aerosol effects on the R n . s w was carried out on a spectrally-homogeneous desert area located in the southwestern Nile Delta. The results reveal that the R n . s w available for energy exchange between the land and atmosphere reduces the accuracy (NRMSE ≃ 14% when the local aerosol microphysical properties are not considered during the processing of space data. Consequently, these findings suggest that the aerosol type should be considered for variables retrieved by satellite observations concerning the energy exchange in the natural ecosystems, such as Photosynthetically-Active Radiation (PAR. This will also improve the accuracy of land monitoring and of solar energy for power generation when space data are used.

  10. Radiation Engineering for Designers

    Science.gov (United States)

    Pellish, Jonathan A.

    2015-01-01

    This tutorial provides an overview of the natural space radiation environment, an introduction to radiation effect types, an overview of EEE parts selection, scrubbing, and radiation mitigation, and an introduction to radiation testing.

  11. Acute Radiation Syndrome

    Science.gov (United States)

    ... Matters Information on Specific Types of Emergencies Acute Radiation Syndrome (ARS): A Fact Sheet for the Public ... is called the radiation dose. People exposed to radiation will get ARS only if: The radiation dose ...

  12. Centaurus A galaxy, type EO peculiar elliptical, also radio source

    Science.gov (United States)

    2002-01-01

    Centaurus A galaxy, type EO peculiar elliptical, also radio source. CTIO 4-meter telescope, 1975. NGC 5128, a Type EO peculiar elliptical galaxy in the constellation Centaurus. This galaxy is one of the most luminous and massive galaxies known and is a strong source of both radio and X-ray radiation. Current theories suggest that the nucleus is experiencing giant explosions involving millions of stars and that the dark band across the galactic disk is material being ejected outward. Cerro Toloto 4-meter telescope photo. Photo credit: National Optical Astronomy Observatories

  13. Line blanketing without local thermodynamic equilibrium. II - A solar-type model in radiative equilibrium

    Science.gov (United States)

    Anderson, Lawrence S.

    1989-01-01

    A statistical solution for the problem of non-LTE radiative transfer in the millions of atomic transitions responsible for line blanketing is proposed which takes into account the influence of scattering on the atomic populations. A multifrequency/multigray algorithm is used to analyze the thermal equilibrium. Although CO is shown to cool the upper atmosphere to a boundary temperature of 2640 K, the molecule has little influence in the region of the solar temperature minimum.

  14. Development of a moisture meter for milled layer. Jyrsoeksen kosteusmittarin kehittaeminen

    Energy Technology Data Exchange (ETDEWEB)

    Aho, V.J.; Leinonen, A.; Hyvaerinen, T.

    1989-02-01

    The purpose of the present paperis to report the development of a continuously operating moisture meter for milled peat layer. The moisture meter is based on the NIR (Near Infra-red) reflection measuring technique. The meter's detector consists of a Near Infra-red radiation detector, elements for optical measuring, a two-channel Infra-red detector, and an electronic signal processor. This moisture meter system also contains a field operable microcomputer for storing measurement data and a printer for taking print-outs during the measurements. The detector and its accessories are installed onto a carriage which can be pulled along on a bog. The results from various measuring tests, and the differences between these results and the results obtained from measuring samples taken by hand are reported. In addition, the paper describes experiences received from using the homogenization equipment. An lastly, plans for further development of the continuously operating and field operable moisture meter for milled layer are outlined.

  15. Study of a three-phase flow metering process for oil-water-gas flows; Etude d`un procede de mesure des debits d`un ecoulement triphasique de type eau-huile-gaz

    Energy Technology Data Exchange (ETDEWEB)

    Boyer, Ch.

    1996-11-01

    We propose a theoretical and experimental study of a three-phase flow metering process for oil-water-gas flows. The selected process is based on a combination of a mixer, a Venturi and ultrasonic methods. To perform an experimental validation of this process an instrumented set-up for three-phase air-oil-water flows has been designed, conceived and adjusted. An original theoretical model have been built to predict three-phase dispersed flows across a contraction. Once validated with two-phase air-water, oil-water and air-oil-water flows data, this model has been used to solve the Venturi metering problems. After a critical review of the available techniques, the ultrasonic propagation velocity has been selected to determine two-phase liquid-liquid flow composition. Two original models have been developed to describe the ultrasonic propagation with the dispersed phase fraction. The comparison with experimental data in oil-water flows show the superiority of one of the two models, the scattering model. For the void fraction determination in air-water flows, the work of Bensler (1990) based on the ultrasonic attenuation measurement has been extended to take into account the multiple scattering effects. Finally these techniques have been combined to determine the different flow rates in air-water, oil-water flows. For two-phase air-water and oil-water flows the problem is solved and the flow rates are measured with a very good accuracy ({+-} 3%). The results quality obtained with three-phase oil-water-gas flows and the secure theoretical bases allowing their interpretation give us the opportunity to strongly recommend the development of an industrial prototype based on the process we studied. (author) 183 refs.

  16. P-stop isolation study of irradiated n-in-p type silicon strip sensors for harsh radiation environment

    CERN Document Server

    AUTHOR|(CDS)2084505

    2015-01-01

    In order to determine the most radiation hard silicon sensors for the CMS Experiment after the Phase II Upgrade in 2023 a comprehensive study of silicon sensors after a fluence of up to $1.5\\times10^{15} n_{eq}/cm^{2}$ corresponding to $3000 fb^{-1}$ after the HL-LHC era has been carried out. The results led to the decision that the future Outer Tracker (20~cm${<}R{<}$110~cm) of CMS will consist of n-in-p type sensors. This technology is more radiation hard but also the manufacturing is more challenging compared to p-in-n type sensors due to additional process steps in order to suppress the accumulation of electrons between the readout strips. One possible isolation technique of adjacent strips is the p-stop structure which is a p-type material implantation with a certain pattern for each individual strip. However, electrical breakdown and charge collection studies indicate that the process parameters of the p-stop structure have to be carefully calibrated in order to achieve a sufficient strip isolatio...

  17. Radiative seesaw-type mechanism of fermion masses and non-trivial quark mixing

    Energy Technology Data Exchange (ETDEWEB)

    Arbelaez, Carolina; Hernandez, A.E.C.; Kovalenko, Sergey; Schmidt, Ivan [Universidad Tecnica Federico Santa Maria, Centro Cientifico-Tecnologico de Valparaiso-CCTVal, Valparaiso (Chile)

    2017-06-15

    We propose a predictive inert two-Higgs doublet model, where the standard model (SM) symmetry is extended by S{sub 3} x Z{sub 2} x Z{sub 12} and the field content is enlarged by extra scalar fields, charged exotic fermions and two heavy right-handed Majorana neutrinos. The charged exotic fermions generate a non-trivial quark mixing and provide one-loop-level masses for the first- and second-generation charged fermions. The masses of the light active neutrinos are generated from a one-loop-level radiative seesaw mechanism. Our model successfully explains the observed SM fermion mass and mixing pattern. (orig.)

  18. Radiative seesaw-type mechanism of fermion masses and non-trivial quark mixing

    Science.gov (United States)

    Arbeláez, Carolina; Hernández, A. E. Cárcamo; Kovalenko, Sergey; Schmidt, Ivan

    2017-06-01

    We propose a predictive inert two-Higgs doublet model, where the standard model (SM) symmetry is extended by S3⊗ Z2⊗ Z_{12} and the field content is enlarged by extra scalar fields, charged exotic fermions and two heavy right-handed Majorana neutrinos. The charged exotic fermions generate a non-trivial quark mixing and provide one-loop-level masses for the first- and second-generation charged fermions. The masses of the light active neutrinos are generated from a one-loop-level radiative seesaw mechanism. Our model successfully explains the observed SM fermion mass and mixing pattern.

  19. A Low Memory Solver for Integral Equations of Chandrasekhar Type in the Radiative Transfer Problems

    Directory of Open Access Journals (Sweden)

    Mohammed Yusuf Waziri

    2011-01-01

    of the Jacobian matrix or its approximation. In this paper, we present a new approach that was based on approximating the Jacobian inverse into a diagonal matrix by means of variational technique. Numerical results on well-known benchmarks integral equations involved in the radiative transfer authenticate the reliability and efficiency of the approach. The fact that the proposed method can solve the integral equations without function derivative and matrix storage can be considered as a clear advantage over some other variants of Newton's method.

  20. Acoustic Radiation Force Impulse Elastography in Determining the Effects of Type 1 Diabetes on Pancreas and Kidney Elasticity in Children.

    Science.gov (United States)

    Sağlam, Dilek; Bilgici, Meltem Ceyhan; Kara, Cengiz; Yılmaz, Gülay Can; Çamlıdağ, İlkay

    2017-11-01

    The aim of this study is to determine the effects of type 1 diabetes on pancreas and kidney elasticity in children, using acoustic radiation force impulse ultrasound elastography. Sixty autoantibody-positive patients with type 1 diabetes (45% girls; mean [± SD] age, 11.7 ± 4.4 years; range, 1.9-19.3 years) admitted to the pediatric endocrinology outpatient clinic and 32 healthy children (50% girls; mean age, 10.2 ± 3.8 years; range, 2.1-17.3 years) were included in the study. Acoustic radiation force impulse elastography measurements were performed of the kidneys and pancreas in both groups. Body mass index, duration of diabetes, HbA1c levels, and insulin dosage of patients with type 1 diabetes were recorded. The mean shear-wave velocities of the pancreas were 0.99 ± 0.25 m/s in patients with type 1 diabetes and 1.09 ± 0.22 m/s in healthy control subjects; the difference was not significant (p = 0.08). The median shear-wave velocities of the right and left kidneys in patients with type 1 diabetes were 2.43 ± 0.29 and 2.47 ± 0.25 m/s, respectively. There were no significant differences in the shear-wave velocities of the right and left kidneys between the patients with type 1 diabetes and the healthy control subjects (p = 0.91 and p = 0.73, respectively). Correlation analysis showed no correlation between the shear-wave velocities of the pancreas and kidney versus HbA1c level, duration of diabetes, insulin dosage, height, weight, and body mass index of the patients with type 1 diabetes. The current study showed no significant difference in the shear-wave velocity of kidneys in children with type 1 diabetes with normoalbuminuria compared with the healthy control subjects. We also observed that the shear-wave velocity of the pancreas in children with type 1 diabetes and healthy control subjects did not differ significantly.

  1. The Research on Metrological Characteristics of House Water Meters during Transitional Flow Regimes

    Directory of Open Access Journals (Sweden)

    Inga Briliūtė

    2011-04-01

    Full Text Available The purpose of this research is to find the influence of transitional flow regimes on inlet water meters. Four construction types of mechanical inlet water meters (each capacity Q = 10 m3/h were investigated. The biggest additional volume 0,12–0,26% when Q = 0,2…2 m3/h shows single-jet vane wheel meter. This additional volume is less 0,06–0,13% for the multi-jet concentric water meter. The minimum influence of transitional flow regimes was for turbine water meters till 0,1% for all flow range. The volumetric meters are not sensitive for this effect.Article in Lithuanian

  2. Comparison of Two Types of Meditation on Patients' Psychosocial Responses During Radiation Therapy for Head and Neck Cancer.

    Science.gov (United States)

    Boxleitner, Gisela; Jolie, Shelley; Shaffer, Dana; Pasacreta, Nicholas; Bai, Mei; McCorkle, Ruth

    2017-05-01

    Radiation treatment for head and neck cancer introduces adaptive demands and subjects patients to significant and unique psychosocial challenges. There is growing evidence that meditation is useful in lessening anxiety and depression in cancer patients. This study compared the effects of two types of meditation training on the psychological responses of patients with head and neck cancer during radiation therapy. Randomized clinical trial. Smilow Cancer Hospital at Yale New Haven. A total of 29 patients with head and neck cancers were recruited and 28 patients were followed during their radiation therapy over 12 weeks. Depending on their group assignment, patients were taught one of two standardized meditations: meditation with a coach or self-meditation with a CD. Patient psychosocial responses were defined as anxiety, depression, and emotional distress and were measured by the Hospital and Anxiety Depression Scale (HADS) and the Emotional Distress Thermometer. Measures were self-reported and collected by the nurse manager at baseline and 6 and 12 weeks during the patient's scheduled weekly visit. No significant mean differences were found between the two meditation groups on all three outcomes: anxiety, depression, and emotional distress. Patients in both the meditation with a coach and self-meditation with a CD groups reported less distress from baseline and at 6 and 12 weeks, as evidenced by the HADS anxiety scale. This study demonstrated two equally effective meditation techniques that can be implemented with patients experiencing high stress during radiation treatments in any health care setting to decrease patient anxiety, depression, and emotional distress. The data established self-meditation with a CD as a more cost-effective alternative to meditation with a coach, which requires intensive training and time commitment for patients.

  3. A genotoxic analysis of the hematopoietic system after mobile phone type radiation exposure in rats.

    Science.gov (United States)

    Kumar, Gaurav; McIntosh, Robert L; Anderson, Vitas; McKenzie, Ray J; Wood, Andrew W

    2015-08-01

    In our earlier study we reported that 900 MHz continuous wave (CW) radiofrequency radiation (RFR) exposure (2 W/kg specific absorption rate [SAR]) had no significant effect on the hematopoietic system of rats. In this paper we extend the scope of the previous study by testing for possible effects at: (i) different SAR levels; (ii) both 900 and 1800 MHz, and; (iii) both CW and pulse modulated (PM) RFR. Excised long bones from rats were placed in medium and RFR exposed in (i) a Transverse Electromagnetic (TEM) cell or (ii) a waveguide. Finite-difference time-domain (FDTD) numerical analyses were used to estimate forward power needed to produce nominal SAR levels of 2/10 and 2.5/12.4 W/kg in the bone marrow. After exposure, the lymphoblasts were extracted and assayed for proliferation rate, and genotoxicity. Our data did not indicate any significant change in these end points for any combination of CW/PM exposure at 900/1800 MHz at SAR levels of nominally 2/10 W/kg or 2.5/12.4 W/kg. No significant changes were observed in the hematopoietic system of rats after the exposure of CW/PM wave 900 MHz/1800 MHz RF radiations at different SAR values.

  4. Radiation Resources Outside of EPA

    Science.gov (United States)

    EPA does not license nuclear power plants or regulate the non-ionizing radiation from cell phones, smart meters or power lines. This page provides links to the state and federal agencies that regulate these matters.

  5. Repair of the three main types of bipyrimidine DNA photoproducts in human keratinocytes exposed to UVB and UVA radiations.

    Science.gov (United States)

    Courdavault, Sophie; Baudouin, Caroline; Charveron, Marie; Canguilhem, Bruno; Favier, Alain; Cadet, Jean; Douki, Thierry

    2005-07-12

    Induction of DNA damage by solar UV radiation is a key event in the development of skin cancers. Bipyrimidine photoproducts, including cyclobutane pyrimidine dimers (CPDs), (6-4) photoproducts (64 PPs) and their Dewar valence isomers, have been identified as major UV-induced DNA lesions. In order to identify the predominant and most persistent lesions, we studied the repair of the three types of photolesions in primary cultures of human keratinocytes. Specific and quantitative data were obtained using HPLC associated with tandem mass spectrometry. As shown in other cell types, 64 PPs are removed from UVB-irradiated keratinocytes much more efficiently than CPDs. In contrast, CPDs are still present in high amounts when cells recover their proliferation capacities after cell cycle arrest and elimination of a part of the population by apoptosis. The predominance of CPDs is still maintained when keratinocytes are exposed to a combination of UVB and UVA. Under these conditions, 64 PPs are converted into their Dewar valence isomers that are as efficiently repaired as their (6-4) precursors. Exposure of cells to pure UVA radiation generates thymine cyclobutane dimers that are slightly less efficiently repaired than CPDs produced upon UVB irradiation. Altogether, our results show that CPDs are the most frequent and the less efficiently repaired bipyrimidine photoproducts irrespectively of the applied UV treatment.

  6. Simplified Processing Method for Meter Data Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Fowler, Kimberly M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Colotelo, Alison H. A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Downs, Janelle L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Ham, Kenneth D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Henderson, Jordan W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Montgomery, Sadie A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Vernon, Christopher R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Parker, Steven A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-11-01

    Simple/Quick metered data processing method that can be used for Army Metered Data Management System (MDMS) and Logistics Innovation Agency data, but may also be useful for other large data sets. Intended for large data sets when analyst has little information about the buildings.

  7. FLOW METERS WITH VERY GOOD PERFORMANCES

    Directory of Open Access Journals (Sweden)

    Mircea Dimitrie CAZACU

    2011-11-01

    Full Text Available We present the theoretical calculus of a patented flow meter, concerning such the thermodynamic and aerodynamic calculus, as well as the offered precision to measure the flow of the air in any meteorological conditions. In the same time we remark that the proposed flow meter, by its positioning, has not loss of head.

  8. A prepaid meter using mobile communication

    African Journals Online (AJOL)

    user

    prepaid card remotely through mobile communication based on customer requests. A prior billing is bound to do away with the problems of unpaid bills and human error in meter readings, thereby ensuring justified revenue for the utility. The proposed prepaid meter is implemented in a software model and Matlab has been ...

  9. [Research on Spectrum Radiation Characteristics of a New Type Infrared/ Ultraviolet Dual Color Decoy].

    Science.gov (United States)

    Chen, Chun-sheng; Dai, Meng-yan; Liu, Hai-feng; Xie, Chang-you; Zhang, Tong; Fang, Guo-feng

    2015-07-01

    The advantage of traditional MTV infrared decoys which are mainly consist of magnesium, Teflon and VITON is that it emits high radiant energy, so it is an effective countermeasure to traditional seekers which seek the target by heat source. The spectral radiant intensity which generated from high temperature combustion of MTV infrared decoys in near infrared region and ultraviolet band is very high, and that in Mid-IR region is relative lower, however the radiant intensity of real jet fighter in ultraviolet band is low and the infrared radiant intensity ratio of Mid-IR to near IR band is greater than 1. Thus, the traditional MTV infrared decoys are hardly able to counter the seekers equipped with dual color combined guidance system. Based on the spectral matching principle, we designed and prepared a new infrared/ultraviolet dual color decoy which is mainly consist of oxidant (wt% 45-75), fuel (wt% 10-25), energetic binder (wt% 25-50) and additives. We conducted theoretical calculations on combustion products of the reagent combinations using CEA (Chemic equilibrium & Application) software and initially determined the content of each component of the decoy formulation on the basis of the calculations results, then investigated the infrared radiation characteristics of decoys employing SR5000 spectrum radiometer and remote sensing interferometer spectrometer Tensor37 and analyzed the possible reasons for test results difference of the two systems separately from the test principle and calculation method, the testing environment, stability of testing results and other aspects. We studied the ultraviolet radiation characteristics of decoys using S2000 fiber optical spectrometer and the test results were consistent with the fighter ultraviolet radiant intensity which gained from theoretical calculation. We researched on the temperature characteristics of decoys by Imager IR 8325 mid-infrared thermal imager and it turned out that the dual color decoy is similar to the

  10. Cosmic magnetism in centimeter- and meter-wavelength radio astronomy

    Science.gov (United States)

    Akahori, Takuya; Nakanishi, Hiroyuki; Sofue, Yoshiaki; Fujita, Yutaka; Ichiki, Kiyotomo; Ideguchi, Shinsuke; Kameya, Osamu; Kudoh, Takahiro; Kudoh, Yuki; Machida, Mami; Miyashita, Yoshimitsu; Ohno, Hiroshi; Ozawa, Takeaki; Takahashi, Keitaro; Takizawa, Motokazu; Yamazaki, Dai G.

    2017-12-01

    The magnetic field is ubiquitous in the universe. Though it plays an essential role in various astrophysical phenomena, its real origin and evolution are poorly known. This article reviews the understanding of the latest research concerning magnetic fields in the interstellar medium, the Milky Way Galaxy, external galaxies, active galactic nuclei, clusters of galaxies, and the cosmic web. Particularly, the review is concentrated in the achievements that have been provided by centimeter- and meter-wavelength radio observations. The article also introduces various methods for analyzing linear polarization data, including synchrotron radiation, Faraday rotation, depolarization, and Faraday tomography.

  11. Highly radiating type-III ELMy H-mode with low plasma core pollution

    NARCIS (Netherlands)

    Rapp, J.; M.R. de Baar,; Fundamenski, W.; Brix, M.; Felton, R.; Giroud, C.; Huber, A.; Jachmich, S.; Joffrin, E.; Nunes, I.; van Rooij, G. J.; Stamp, M.; Telesca, G.; Zagorski, R.

    2009-01-01

    The impurity seeded type-III ELMy H-mode is proposed as an integrated ITER scenario. At JET this scenario has been demonstrated up to plasma currents of 3 MA with nitrogen as seeding gas. Detached divertor operation is achieved with significantly reduced steady state and transient heat fluxes. By

  12. Radiative type-III ELMy H-mode in all-tungsten ASDEX Upgrade

    NARCIS (Netherlands)

    Rapp, J.; Kallenbach, A.; Neu, R.; Eich, T.; Fischer, R.; Herrmann, A.; Potzel, S.; van Rooij, G. J.; Zielinski, J. J.; ASDEX Upgrade team,

    2012-01-01

    The type-III ELMy H-mode might be the solution for an integrated ITER operation scenario fulfilling the fusion power amplification factor (output fusion power to input heating power) of Q = 10 with simultaneous acceptable steady-state and transient power loads to the plasma-facing components. This

  13. Bandwidth Analysis of Smart Meter Network Infrastructure

    DEFF Research Database (Denmark)

    Balachandran, Kardi; Olsen, Rasmus Løvenstein; Pedersen, Jens Myrup

    2014-01-01

    Advanced Metering Infrastructure (AMI) is a net-work infrastructure in Smart Grid, which links the electricity customers to the utility company. This network enables smart services by making it possible for the utility company to get an overview of their customers power consumption and also control...... to utilize smart meters and which existing broadband network technologies can facilitate this smart meter service. Initially, scenarios for smart meter infrastructure are identified. The paper defines abstraction models which cover the AMI scenarios. When the scenario has been identified a general overview...... of the bandwidth requirements are analysed. For this analysis the assumptions and limitations are defined. The results obtained by the analysis show, that the amount of data collected and transferred by a smart meter is very low compared to the available bandwidth of most internet connections. The results show...

  14. Historical Patterns in the Types of Procedures Performed and Radiation Safety Practices Used in Nuclear Medicine From 1945-2009.

    Science.gov (United States)

    Van Dyke, Miriam E; Drozdovitch, Vladimir; Doody, Michele M; Lim, Hyeyeun; Bolus, Norman E; Simon, Steven L; Alexander, Bruce H; Kitahara, Cari M

    2016-07-01

    The authors evaluated historical patterns in the types of procedures performed in diagnostic and therapeutic nuclear medicine and the associated radiation safety practices used from 1945-2009 in a sample of U.S. radiologic technologists. In 2013-2014, 4,406 participants from the U.S. Radiologic Technologists (USRT) Study who previously reported working with medical radionuclides completed a detailed survey inquiring about the performance of 23 diagnostic and therapeutic radionuclide procedures and the use of radiation safety practices when performing radionuclide procedure-related tasks during five time periods: 1945-1964, 1965-1979, 1980-1989, 1990-1999, and 2000-2009. An overall increase in the proportion of technologists who performed specific diagnostic or therapeutic procedures was observed across the five time periods. Between 1945-1964 and 2000-2009, the median frequency of diagnostic procedures performed substantially increased (from 5 wk to 30 wk), attributable mainly to an increasing frequency of cardiac and non-brain PET scans, while the median frequency of therapeutic procedures performed modestly decreased (from 4 mo to 3 mo). Also a notable increase was observed in the use of most radiation safety practices from 1945-1964 to 2000-2009 (e.g., use of lead-shielded vials during diagnostic radiopharmaceutical preparation increased from 56 to 96%), although lead apron use dramatically decreased (e.g., during diagnostic imaging procedures, from 81 to 7%). These data describe historical practices in nuclear medicine and can be used to support studies of health risks for nuclear medicine technologists.

  15. Historical patterns in the types of procedures performed and radiation safety practices used in nuclear medicine from 1945–2009

    Science.gov (United States)

    Van Dyke, Miriam E.; Drozdovitch, Vladimir; Doody, Michele M.; Lim, Hyeyeun; Bolus, Norman E.; Simon, Steven L.; Alexander, Bruce H.; Kitahara, Cari M.

    2016-01-01

    We evaluated historical patterns in the types of procedures performed in diagnostic and therapeutic nuclear medicine and the associated radiation safety practices used from 1945–2009 in a sample of U.S. radiologic technologists. In 2013–2014, 4,406 participants from the U.S. Radiologic Technologists (USRT) Study who previously reported working with medical radionuclides completed a detailed survey inquiring about the performance of 23 diagnostic and therapeutic radionuclide procedures and the use of radiation safety practices when performing radionuclide procedure-related tasks during five time periods: 1945–1964, 1965–1979, 1980–1989, 1990–1999, and 2000–2009. We observed an overall increase in the proportion of technologists who performed specific diagnostic or therapeutic procedures across the five time periods. Between 1945–1964 and 2000–2009, the median frequency of diagnostic procedures performed substantially increased (5 per week to 30 per week), attributable mainly to an increasing frequency of cardiac and non-brain PET scans, while the median frequency of therapeutic procedures performed modestly decreased (from 4 per month to 3 per month). We also observed a notable increase in the use of most radiation safety practices from 1945–1964 to 2000–2009 (e.g., use of lead-shielded vials during diagnostic radiopharmaceutical preparation increased from 56 to 96%), although lead apron use dramatically decreased (e.g., during diagnostic imaging procedures, from 81 to 7%). These data describe historical practices in nuclear medicine and can be used to support studies of health risks in nuclear medicine technologists. PMID:27218293

  16. Simple meters get smart? Cost benefit analysis of smart metering infrastructure; Domme meters worden slim? Kosten-batenanalyse slimme meetinfrastructuur

    Energy Technology Data Exchange (ETDEWEB)

    Van Gerwen, R.J.F.; Jaarsma, S.A.; Koenis, F.T.C. [KEMA T and D Consulting, Arnhem (Netherlands)

    2005-08-15

    The Dutch Ministry of Economic Affairs requested a cost-benefit analysis of the large scale introduction of a smart meter infrastructure for gas and electricity consumption by small consumers. The questions asked in the study need to be answered in order to enable a well-founded evaluation of the implementation of smart meters. [mk]. [Dutch] Het Ministerie van Economische Zaken heeft een kosten-batenanalyse laten uitvoeren naar de grootschalige introductie van een slimme meetinfrastructuur voor gas- en elektriciteitsverbruik door kleinverbruikers. De in het onderzoek gestelde vragen moeten beantwoord worden om een goed gefundeerd oordeel te kunnen geven over de invoering van slimme meters.

  17. Method for detecting and distinguishing between specific types of environmental radiation using a high pressure ionization chamber with pulse-mode readout

    Energy Technology Data Exchange (ETDEWEB)

    Degtiarenko, Pavel V.

    2017-12-19

    An environmental radiation detector for detecting and distinguishing between all types of environmental radiation, including photons, charged particles, and neutrons. A large volume high pressure ionization chamber (HPIC) includes BF.sub.3 gas at a specific concentration to render the radiation detector sensitive to the reactions of neutron capture in Boron-10 isotope. A pulse-mode readout is connected to the ionization chamber capable of measuring both the height and the width of the pulse. The heavy charged products of the neutron capture reaction deposit significant characteristic energy of the reaction in the immediate vicinity of the reaction in the gas, producing a signal with a pulse height proportional to the reaction energy, and a narrow pulse width corresponding to the essentially pointlike energy deposition in the gas. Readout of the pulse height and the pulse width parameters of the signals enables distinguishing between the different types of environmental radiation, such as gamma (x-rays), cosmic muons, and neutrons.

  18. Monitoring system for gamma radiation of porch type for vehicles; Sistema de monitoreo de radiacion gamma tipo portal para vehiculos

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez C, R.M.; Molina, G.; Gutierrez O, E.; Ramirez J, F.J.; Garcia H, J.M.; Aguilar B, M.A.; Vilchis P, A.E.; Cruz E, P.; Torres B, M.A. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2005-07-01

    A monitoring system of gamma radiation for vehicles of the porch type developed in the ININ is presented. This system carries out the radiological monitoring of the vehicles in continuous form, detecting the bottom radiological environment and the presence of nuclear material transported in vehicles. The vehicles are monitored while they pass to low speed through the porch. The detectors are plastic scintillators of great volume that allow high sensibility detection. The arrangement of detecting is interconnected in net, and the data are concentrated on a personal computer whose interface man-machine can be accessed from any personal computer connected to Internet. The system monitoring in real time with options of sampling times from 50 ms configurable up to 500 ms. (Author)

  19. Radiation stimulated effects in crystals of quartz and berlinit with different type and degree of perfection structure

    CERN Document Server

    Ibragimov, Z D

    2001-01-01

    of structure. The effectiveness of creation of additional defects near defects of one type is increased with growth of concentration of other types of structure violations. It was established that in crystals of quartz and berlinit alpha-beta-transition during neutron irradiation occurs through formation of seeds of beta-phase. It was shown that the grown layer with beta-phase inherited also neutron induced defects of alpha-phase as well as defects related to beta-phase of quartz. The structure of amorphous phase formed around seeds of beta-phase differs from quartz glass structure. The formation of regions with structure closed to quartz glass structure occurs after definite neutron fluence values. In quartz crystals there are several defect centers emitting in red spectral range. The processes of impact and non-impact production of point defects, mechanisms of structure transformations in quartz and berlinit crystals irradiated by various types of radiation with over- and sub- threshold energy were studied....

  20. Study of the effect of different type of aerosols on UV-B radiation from measurements during EARLINET

    Directory of Open Access Journals (Sweden)

    D. S. Balis

    2004-01-01

    Full Text Available Routine lidar measurements of the vertical distribution of the aerosol extinction coefficient and the extinction-to-backscatter ratio have been performed at Thessaloniki, Greece using a Raman lidar system in the frame of the EARLINET project since 2000. Co-located spectral and broadband solar UV-B irradiance measurements, as well as total ozone observations, were available whenever lidar measurements were obtained. From the available measurements several cases could be identified that allowed the study of the effect of different types of aerosol on the levels of the UV-B solar irradiance at the Earth's surface. The TUV radiative transfer model has been used to simulate the irradiance measurements, using total ozone and the lidar aerosol data as input. From the comparison of the model results with the measured spectra the effective single scattering albedo was determined using an iterative procedure, which has been verified against results from the 1998 Lindenberg Aerosol Characterization Experiment. It is shown that for the same aerosol optical depth and for the same total ozone values the UV-B irradiances at the Earth's surface can show differences up to 10%, which can be attributed to differences in the aerosol type. It is shown that the combined use of the estimated single scattering albedo and of the measured extinction-to-backscatter ratio leads to a better characterization of the aerosol type probed.

  1. Midinfrared Photoluminescence up to 290 K Reveals Radiative Mechanisms and Substrate Doping-Type Effects of InAs Nanowires.

    Science.gov (United States)

    Chen, Xiren; Zhuang, Qiandong; Alradhi, H; Jin, Zh M; Zhu, Liangqing; Chen, Xin; Shao, Jun

    2017-03-08

    Photoluminescence (PL) as a conventional yet powerful optical spectroscopy may provide crucial insight into the mechanism of carrier recombination and bandedge structure in semiconductors. In this study, mid-infrared PL measurements on vertically aligned InAs nanowires (NWs) are realized for the first time in a wide temperature range of up to 290 K, by which the radiative recombinations are clarified in the NWs grown on n- and p-type Si substrates, respectively. A dominant PL feature is identified to be from the type-II optical transition across the interfaces between the zinc-blend (ZB) and the wurtzite (WZ) InAs, a lower-energy feature at low temperatures is ascribed to impurity-related transition, and a higher-energy feature at high temperatures originates in the interband transition of the WZ InAs being activated by thermal-induced electron transfer. The optical properties of the ZB-on-WZ and WZ-on-ZB interfaces are asymmetric, and stronger nonradiative recombination and weaker carrier-phonon interaction show up in the NWs on p-type substrate in which built-in electric field forms and leads to carrier assembling around the WZ-on-ZB interface. The results indicate that wide temperature-range infrared PL analysis can serve as efficient vehicle for clarifying optical properties and bandedge processes of the crystal-phase interfaces in vertically aligned InAs NWs.

  2. Handheld Multi-Gas Meters Market Survey Report

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Gustavious [Brigham Young Univ., Provo, UT (United States); Wald-Hopkins, Mark David [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Obrey, Stephen J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Akhadov, Valida Dushdurova [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-06-23

    Handheld multi-gas meters (MGMs) are equipped with sensors to monitor oxygen (O2) levels and additional sensors to detect the presence of combustible or toxic gases in the environment. This report is limited to operational response-type MGMs that include at least four different sensors. These sensors can vary by type and by the chemical monitored. In real time, the sensors report the concentration of monitored gases in the atmosphere near the MGM. To provide emergency responders with information on handheld multi-gas meters, the System Assessment and Validation for Emergency Responders (SAVER) Program conducted a market survey. This market survey report is based on information gathered between November 2015 and February 2016 from vendors, Internet research, industry publications, an emergency responder focus group, and a government issued Request for Information (RFI) that was posted on the Federal Business Opportunities website.

  3. PELATIHAN LARI SAMBUNG BACK TO BACK 20 METER ENAM REPETISI EMPAT SET DAN LARI SAMBUNG BACK TO BACK 30 METER EMPAT REPETISI EMPAT SET MENINGKATKAN KECEPATAN LARI 80 METER SISWA PUTRA SMP DHARMA PRAJA BADUNG

    Directory of Open Access Journals (Sweden)

    Gimbar Adiputra

    2015-08-01

    Full Text Available Type of 80 meters ran is one of the numbers on athletics competed in early age of child. In early age, the physical condition and mind can still be developed continuously and systematically. The exercise in early age should be an element of play and competition, thus this exercise is attempted to develop the speed by two types of exercise: back to back relay run of 20 meters six reps four sets and back to back relay run of 30 meters four reps four sets. The aim of research is to know the increasing of 80 meters speed of run. The exercise was conducted for six weeks with a frequency of three times a week with the aim to increasing the speed. The numbered of sample was 24 people selected randomly from junior high school students of Dharma Praja Badung that meets the requirements of inclusion and exclusion. The numbered of each group consists of twelve people. Each group was given a different treatment i.e. group I was treated by back to back relay run of 20 meters six reps and four sets and group II treated by back to back relay run of 30 meters four reps four sets. Data derived from the duration time of 80 meters ran before and after exercise, with t paired test to determine the difference average speed of duration time before and after exercise in each group. The t Unpaired test for the difference average of increased speed between two groups with significance limit of 0.05. The differences of speed in 80 meters ran after exercise in both groups showed significant differences, i.e. p = 0.000 (p <0.05. The average of duration time of 80 meters ran in Group I before exercise was 13.51 sec and after exercise was 12.31 sec by difference of 1.16 seconds show significant differences, while Group 2 the average of duration time in 80 meters ran before exercise and after exercise was 13.66 and after 12, 67 by a difference of 0.98 seconds showed significant differences due to differences in distance and number of repetitions between Group I and Group II

  4. The development of p-type silicon detectors for the high radiation regions of the LHC

    CERN Document Server

    Hanlon, M D L

    1998-01-01

    This thesis describes the production and characterisation of silicon microstrip detectors and test structures on p-type substrates. An account is given of the production and full parameterisation of a p-type microstrip detector, incorporating the ATLAS-A geometry in a beam test. This detector is an AC coupled device incorporating a continuous p-stop isolation frame and polysilicon biasing and is typical of n-strip devices proposed for operation at the LHC. It was successfully read out using the FELix-128 analogue pipeline chip and a signal to noise (s/n) of 17+-1 is reported, along with a spatial resolution of 14.6+-0.2 mu m. Diode test structures were fabricated on both high resistivity float zone material and on epitaxial material and subsequently irradiated with 24 GeV protons at the CERN PS up to a dose of (8.22+-0.23) x 10 sup 1 sup 4 per cm sup 2. An account of the measurement program is presented along with results on the changes in the effective doping concentration (N sub e sub f sub f) with irradiat...

  5. The prevalence of second harmonic radiation in type III bursts observed at kilometric wavelengths.

    Science.gov (United States)

    Haddock, F. T.; Alvarez, H.

    1973-01-01

    We present the analysis of 64 type III solar bursts that drifted from 3.5 MHz down to the range 350-50 kHz between March 1968 and February 1970. Bursts arrival times were predicted by a simple model and then compared with observations. The results show that, as the bursts drift, the fundamental often disappears below a certain frequency range while the second harmonic remains. Below about 1 MHz, the second harmonic occurrence predominates. Recognizing this fact we deduce a mean velocity of 0.32c plus or minus 0.02c for the exciter particles, where the uncertainty is the standard error and c the velocity of light in vacuum; the electron density model used is comparable to a solar wind model.

  6. Soft-sensing, non-intrusive multiphase flow meter

    NARCIS (Netherlands)

    Wrobel, K.; Schiferli, W.

    2009-01-01

    For single phase flow meters more and better non-intrusive or even clamp-on meters become available. This allows for a wider use of meters and for easier flow control. As the demand for multiphase meters is increasing, the current aim is to develop a non-intrusive multiphase flow meter. The

  7. IM-1662 Attenuates Radiation-Induced Fibroblast Differentiation through Restoration of TGF-beta type III Receptor

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sa Rah; Ahn, Ji Yeon; Kim, Mi Hyoung; Lim, Min Jin; Lee, Sae Loom; Yun, Yeon Sook; Song, Jie Young [Korea Institue of Radiological and Medical Sciences, Seoul (Korea, Republic of)

    2010-05-15

    Although pulmonary fibrosis occurs 5-20% of lung cancer patients who underwent radiotherapy, clinically standard treatment for fibrotic disease has not been developed yet. Among fibrosis mediating factors such as transforming growth factor-beta (TGF-beta), connective tissue growth factor (CTGF), platelet derived growth factor (PDGF), fibroblast growth factor (FGF), interleukin-13 (IL-13), IL-4, interferon-gamma (IFN-gamma), and tumor necrosis factor (TNF-alpha), TGF-beta is considered as a critical mediator in normal wound healing as well as pathological fibrogenic processes. The TGF-beta transmits signals either directly or indirectly through types I, II and III (TbetaRI, II, and III) receptor complexes and activates downstream Smad signaling. The type III TGF-beta receptor (TbetaRIII or betaglycan) is a transmembrane proteoglycan without a functional kinase domain, and is regarded as a co-receptor to increase the affinity of ligand binding to TbetaRII. In addition, TbetaRIII act as a regulator in cell migration, invasion and cell growth in cancer models. However, in contrast to a great number of studies about TGF-beta ligand and TbetaRII signaling, the relationship between TGF-beta and TbetaRIII (or betaglycan) remains largely unknown. In this study, we searched for a new compound which inhibited TGF-beta responses using cell-based chemical screening and investigated the effects of the novel compound on radiation induced myofibroblast differentiation. We suggest that a novel small molecule, pyrazolopyrimidine compound IM-1662, can act as an anti-fibrotic agent through inhibiting expression of TGF-beta receptor type I and type II whereas, preserving the levels of TbetaRIII which seems to act as a negative regulator in TGF-beta signaling

  8. EPA Region 1 - Valley Depth in Meters

    Data.gov (United States)

    U.S. Environmental Protection Agency — Raster of the Depth in meters of EPA-delimited Valleys in Region 1. Valleys (areas that are lower than their neighbors) were extracted from a Digital Elevation Model...

  9. EMMNet: sensor networking for electricity meter monitoring.

    Science.gov (United States)

    Lin, Zhi-Ting; Zheng, Jie; Ji, Yu-Sheng; Zhao, Bao-Hua; Qu, Yu-Gui; Huang, Xu-Dong; Jiang, Xiu-Fang

    2010-01-01

    Smart sensors are emerging as a promising technology for a large number of application domains. This paper presents a collection of requirements and guidelines that serve as a basis for a general smart sensor architecture to monitor electricity meters. It also presents an electricity meter monitoring network, named EMMNet, comprised of data collectors, data concentrators, hand-held devices, a centralized server, and clients. EMMNet provides long-distance communication capabilities, which make it suitable suitable for complex urban environments. In addition, the operational cost of EMMNet is low, compared with other existing remote meter monitoring systems based on GPRS. A new dynamic tree protocol based on the application requirements which can significantly improve the reliability of the network is also proposed. We are currently conducting tests on five networks and investigating network problems for further improvements. Evaluation results indicate that EMMNet enhances the efficiency and accuracy in the reading, recording, and calibration of electricity meters.

  10. Informatics Solutions for Smart Metering Systems Integration

    Directory of Open Access Journals (Sweden)

    Simona-Vasilica OPREA

    2015-01-01

    Full Text Available In this paper different aspects regarding smart metering systems integration have been depicted. Smart metering systems, renewable energy sources integration and advanced tariff systems implementation require informatics solution that could automatically collect and process data, forecast the behavior of electricity consumers, analyze trends regarding electricity prices, optimize the consumption of consumers, provide friendly interfaces, etc. They are advanced technologies that represent solutions for insufficient conventional primary energy sources, gas emissions, dependency on energy sources located outside European Union and issues related to energy efficiency. This paper mainly describes several informatics solutions correlated with operational requirements for smart metering system and our proposal for simplified architecture of smart metering systems, with three distinct levels (base level, middle level and top level and load profile calculation methods.

  11. SPOT Controlled Image Base 10 meter

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — SPOT Controlled Image Base 10 meter (CIB-10) is a collection of orthorectified panchromatic (grayscale) images. The data were acquired between 1986 and 1993 by the...

  12. New consumer services provided by smart metering

    Directory of Open Access Journals (Sweden)

    Daminov Ildar

    2015-01-01

    Full Text Available This paper focuses on the issues of smart metering market and considers different services provided by smart metering from consumer point of view. Firstly, smart metering deployment challenges emerging and conventional tariffs, which modify a consumer behavior and thus, the entire electric energy market can be optimized since the customer is motivated to consume less energy. Secondly, the authors illustrate changes in electricity quality, which have an impact on consumer relations with utility. Additionally, two main indices of grid resilience – SAIDI and SAIFI – are exemplified to reveal the improvement potential of smart metering implementation in certain regions of Russia that also influence the consumer. Finally, in-home display and privacy problem directly reflect the consumer’s behavior, thus the private life rights should not be violated as they are guaranteed by law.

  13. VT USGS NED DEM (10 meter) - statewide

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) This dataset is derived from the multi-resolution National Elevation Dataset (NED), at resolutions of both 1/3 arc-second (approx. 10 meters) and...

  14. EMMNet: Sensor Networking for Electricity Meter Monitoring

    Directory of Open Access Journals (Sweden)

    Zhi-Ting Lin

    2010-06-01

    Full Text Available Smart sensors are emerging as a promising technology for a large number of application domains. This paper presents a collection of requirements and guidelines that serve as a basis for a general smart sensor architecture to monitor electricity meters. It also presents an electricity meter monitoring network, named EMMNet, comprised of data collectors, data concentrators, hand-held devices, a centralized server, and clients. EMMNet provides long-distance communication capabilities, which make it suitable suitable for complex urban environments. In addition, the operational cost of EMMNet is low, compared with other existing remote meter monitoring systems based on GPRS. A new dynamic tree protocol based on the application requirements which can significantly improve the reliability of the network is also proposed. We are currently conducting tests on five networks and investigating network problems for further improvements. Evaluation results indicate that EMMNet enhances the efficiency and accuracy in the reading, recording, and calibration of electricity meters.

  15. EMMNet: Sensor Networking for Electricity Meter Monitoring

    Science.gov (United States)

    Lin, Zhi-Ting; Zheng, Jie; Ji, Yu-Sheng; Zhao, Bao-Hua; Qu, Yu-Gui; Huang, Xu-Dong; Jiang, Xiu-Fang

    2010-01-01

    Smart sensors are emerging as a promising technology for a large number of application domains. This paper presents a collection of requirements and guidelines that serve as a basis for a general smart sensor architecture to monitor electricity meters. It also presents an electricity meter monitoring network, named EMMNet, comprised of data collectors, data concentrators, hand-held devices, a centralized server, and clients. EMMNet provides long-distance communication capabilities, which make it suitable suitable for complex urban environments. In addition, the operational cost of EMMNet is low, compared with other existing remote meter monitoring systems based on GPRS. A new dynamic tree protocol based on the application requirements which can significantly improve the reliability of the network is also proposed. We are currently conducting tests on five networks and investigating network problems for further improvements. Evaluation results indicate that EMMNet enhances the efficiency and accuracy in the reading, recording, and calibration of electricity meters. PMID:22163551

  16. Blood group typing based on recording the elastic scattering of laser radiation using the method of digital imaging

    Energy Technology Data Exchange (ETDEWEB)

    Dolmashkin, A A; Dubrovskii, V A; Zabenkov, I V [V.I.Razumovsky Saratov State Medical University, Saratov (Russian Federation)

    2012-05-31

    The possibility is demonstrated to determine the human blood group by recording the scattering of laser radiation with the help of the digital imaging method. It is experimentally shown that the action of a standing ultrasound wave leads to acceleration of the agglutination reaction of red blood cells, to formation of larger immune complexes of red blood cells, and, as a consequence, to acceleration of their sedimentation. In the absence of agglutination of red blood cells the ultrasound does not enhance the relevant processes. This difference in the results of ultrasound action on the mixture of blood and serum allows a method of blood typing to be offered. Theoretical modelling of the technique of the practical blood typing, carried out on the basis of the elastic light scattering theory, agrees well with the experimental results, which made it possible to plan further improvement of the proposed method. The studies of specific features of sedimentation of red blood cells and their immune complexes were aimed at the optimisation of the sample preparation, i.e., at the search for such experimental conditions that provide the maximal resolution of the method and the device for registering the reaction of red blood cells agglutination. The results of the study may be used in designing the instrumentation for blood group assessment in humans.

  17. Blood group typing based on recording the elastic scattering of laser radiation using the method of digital imaging

    Science.gov (United States)

    Dolmashkin, A. A.; Dubrovskii, V. A.; Zabenkov, I. V.

    2012-05-01

    The possibility is demonstrated to determine the human blood group by recording the scattering of laser radiation with the help of the digital imaging method. It is experimentally shown that the action of a standing ultrasound wave leads to acceleration of the agglutination reaction of red blood cells, to formation of larger immune complexes of red blood cells, and, as a consequence, to acceleration of their sedimentation. In the absence of agglutination of red blood cells the ultrasound does not enhance the relevant processes. This difference in the results of ultrasound action on the mixture of blood and serum allows a method of blood typing to be offered. Theoretical modelling of the technique of the practical blood typing, carried out on the basis of the elastic light scattering theory, agrees well with the experimental results, which made it possible to plan further improvement of the proposed method. The studies of specific features of sedimentation of red blood cells and their immune complexes were aimed at the optimisation of the sample preparation, i.e., at the search for such experimental conditions that provide the maximal resolution of the method and the device for registering the reaction of red blood cells agglutination. The results of the study may be used in designing the instrumentation for blood group assessment in humans.

  18. Capacitive level meter for liquid rare gases

    Science.gov (United States)

    Sawada, R.; Kikuchi, J.; Shibamura, E.; Yamashita, M.; Yoshimura, T.

    2003-08-01

    An international project to search μ→eγ decay includes the use of a liquid xenon gamma ray detector. So, a liquid level meter working at a low temperature with low outgassing is needed and the prototype is constructed. The meter shows the liquid level by measuring the capacitance between electrodes with small intervals immersed in the liquid. The operation was successful with the estimated precision of 1 mm in RMS or better.

  19. Intelligent Metering for Urban Water: A Review

    Directory of Open Access Journals (Sweden)

    Rodney Stewart

    2013-07-01

    Full Text Available This paper reviews the drivers, development and global deployment of intelligent water metering in the urban context. Recognising that intelligent metering (or smart metering has the potential to revolutionise customer engagement and management of urban water by utilities, this paper provides a summary of the knowledge-base for researchers and industry practitioners to ensure that the technology fosters sustainable urban water management. To date, roll-outs of intelligent metering have been driven by the desire for increased data regarding time of use and end-use (such as use by shower, toilet, garden, etc. as well as by the ability of the technology to reduce labour costs for meter reading. Technology development in the water sector generally lags that seen in the electricity sector. In the coming decade, the deployment of intelligent water metering will transition from being predominantly “pilot or demonstration scale” with the occasional city-wide roll-out, to broader mainstream implementation. This means that issues which have hitherto received little focus must now be addressed, namely: the role of real-time data in customer engagement and demand management; data ownership, sharing and privacy; technical data management and infrastructure security, utility workforce skills; and costs and benefits of implementation.

  20. Radiochromic Plastic Films for Accurate Measurement of Radiation Absorbed Dose and Dose Distributions

    DEFF Research Database (Denmark)

    McLaughlin, W. L.; Miller, Arne; Fidan, S.

    1977-01-01

    Thin radiochromic dye films are useful for measuring large radiation absorbed doses (105–108 rads) and for high-resolution imaging of dose patterns produced by penetrating radiation beams passing through non-homogeneous media. Certain types of amino-substituted triarylmethane cyanides dissolved...... in polymeric solutions can be cast into flexible free-standing thin films of uniform thickness and reproducible response to ultraviolet and ionizing radiation. The increase in optical density versus energy deposited by radiation is linear over a wide range of doses and is for practical purposes independent...... of dose rate (1–1014 rad s−1). Upon irradiation of the film, the profile of the radiation field is registered as a permanent colored image of the dose distribution. Unlike most other types of dyed plastic dose meters, the optical density produced by irradiation is in most cases stable for periods...

  1. Evaluation of the ICRU operational magnitudes implantation for the photon radiation at the Angra I and Angra II nuclear power plants; Avaliacao da implantacao das grandezas operacionais do ICRU para a radiacao de fotons nas usinas nucleares Angra I e II

    Energy Technology Data Exchange (ETDEWEB)

    Viana, Ronaldo do Nascimento

    2006-07-01

    The measurements of photon radiation field intensity are usually performed by a radiation protection technician trained and having skill in using radiation rate meters. Nowadays, these measurements are reported on exposure quantity and used to protect exposed individuals against the radiation risks while executing their activities. The International Commission on Radiation Units and Measurements - ICRU - defined the operational quantity ambient equivalent dose H{sup *}(10). This quantity is accepted by the scientific community as the best estimative of the protection quantity effective dose, which can not be directly measured. The operational quantity H{sup *}(10) was introduced in Brazilian rules by the National Commission of Nuclear Energy - CNEN (2005a), although its adoption was conditioned to studies of convenience and applicability of implementation. The present work may contribute to these studies, as it presents the evaluation of H{sup *}(10)'s implementation at the Nuclear Central Almirante Alvaro Alberto - CNAAA. The evaluation involved radiological tests - the energy dependence and angular dependence - applied to six types of photon radiation rate meters utilized at the CNAAA, with represent around 83% of the total number of rate meters in use by CNAAA. The result of this evaluation is favorable to the quantity H{sup *}(10)'s implementation. Suggestions are presented in order to update de rate meters and the technical and administrative procedures related to the Laboratory of Calibration of Rate Meters - LCMR, belonging to CNAAA. Thus, it could be possible to perform the calibration of the rate meters at the nuclear installation. The results obtained allows to carry out new evaluations of H{sup *}(10)'s implementation on installations that perform measurements with radiation rate meters on the practice of radiation protection, in order to adopt the H{sup *}(10) quantity in our country. (author)

  2. Ion irradiation of electronic-type-separated single wall carbon nanotubes: A model for radiation effects in nanostructured carbon

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, Jamie E. [NanoPower Research Laboratory, Rochester Institute of Technology, Rochester, New York 14623 (United States); Cress, Cory D.; Messenger, Scott R.; Weaver, Brad D. [Electronics Science and Technology Division, United States Naval Research Laboratory, Washington, D.C. 20375 (United States); Helenic, Alysha R.; Landi, Brian J. [NanoPower Research Laboratory, Rochester Institute of Technology, Rochester, New York 14623 (United States); Department of Chemical and Biomedical Engineering, Rochester Institute of Technology, Rochester, New York 14623 (United States); Schauerman, Chris M. [NanoPower Research Laboratory, Rochester Institute of Technology, Rochester, New York 14623 (United States); Golisano Institute of Sustainability, Rochester Institute of Technology, Rochester, New York 14623 (United States); DiLeo, Roberta A.; Cox, Nathanael D. [NanoPower Research Laboratory, Rochester Institute of Technology, Rochester, New York 14623 (United States); Department of Microsystems Engineering, Rochester Institute of Technology, Rochester, New York 14623 (United States); Hubbard, Seth M. [NanoPower Research Laboratory, Rochester Institute of Technology, Rochester, New York 14623 (United States); Department of Microsystems Engineering, Rochester Institute of Technology, Rochester, New York 14623 (United States); Department of Physics, Rochester Institute of Technology, Rochester, New York 14623 (United States)

    2012-08-01

    The structural and electrical properties of electronic-type-separated (metallic and semiconducting) single wall carbon nanotube (SWCNT) thin-films have been investigated after irradiation with 150 keV {sup 11}B{sup +} and 150 keV {sup 31}P{sup +} with fluences ranging from 10{sup 12} to 10{sup 15} ions/cm{sup 2}. Raman spectroscopy results indicate that the ratio of the Raman D to G Prime band peak intensities (D/G Prime ) is a more sensitive indicator of SWCNT structural modification induced by ion irradiation by one order of magnitude compared to the ratio of the Raman D to G band peak intensities (D/G). The increase in sheet resistance (R{sub s}) of the thin-films follows a similar trend as the D/G Prime ratio, suggesting that the radiation induced variation in bulk electrical transport for both electronic-types is equal and related to localized defect generation. The characterization results for the various samples are compared based on the displacement damage dose (DDD) imparted to the sample, which is material and damage source independent. Therefore, it is possible to extend the analysis to include data from irradiation of transferred CVD-graphene films on SiO{sub 2}/Si substrates using 35 keV C{sup +} ions, and compare the observed changes at equivalent levels of ion irradiation-induced damage to that observed in the SWCNT thin-film samples. Ultimately, a model is developed for the prediction of the radiation response of nanostructured carbon materials based on the DDD for any incident ion with low-energy recoil spectra. The model is also related to the defect concentration, and subsequently the effective defect-to-defect length, and yields a maximum defect concentration (minimum defect-to-defect length) above which the bulk electrical transport properties in SWCNT thin-films and large graphene-based electronic devices rapidly degrade when exposed to harsh environments.

  3. A Light-Weight Metering File System for Sustainable Real-Time Meter Data Management

    Directory of Open Access Journals (Sweden)

    Gangman Yi

    2014-09-01

    Full Text Available A real-time smart metering system has strict requirements, since every piece of data gathered from various meters every hour is of importance, and each component consisting of metering infrastructure should be sustainable. Therefore, it is necessary to efficiently manage the meter data set in smart metering networks as well as in a server. Therefore, we propose a dedicated file system, a LIght-weight Metering File System (LIMFS, which is capable of not only efficiently storing and searching meter data but also performing distributed fault-tolerant meter data management for real-time smart meter devices. The proposed LIMFS exploits accumulated data sliding storage (ADSS for lost data recovery and latest-first error-ignorant data management (LEDM to reduce memory wastage, coping with dynamic report interval. Experimental results demonstrate that LIMFS has as a small enough overhead to be considered negligible, and provides flexible memory capacity according to dynamic report interval, in spite of lost data recovery functionality.

  4. An alternative arrangement of metered dosing fluid using centrifugal pump

    Science.gov (United States)

    Islam, Md. Arafat; Ehsan, Md.

    2017-06-01

    Positive displacement dosing pumps are extensively used in various types of process industries. They are widely used for metering small flow rates of a dosing fluid into a main flow. High head and low controllable flow rates make these pumps suitable for industrial flow metering applications. However their pulsating flow is not very suitable for proper mixing of fluids and they are relatively more expensive to buy and maintain. Considering such problems, alternative techniques to control the fluid flow from a low cost centrifugal pump is practiced. These include - throttling, variable speed drive, impeller geometry control and bypass control. Variable speed drive and impeller geometry control are comparatively costly and the flow control by throttling is not an energy efficient process. In this study an arrangement of metered dosing flow was developed using a typical low cost centrifugal pump using bypass flow technique. Using bypass flow control technique a wide range of metered dosing flows under a range of heads were attained using fixed pump geometry and drive speed. The bulk flow returning from the system into the main tank ensures better mixing which may eliminate the need of separate agitators. Comparative performance study was made between the bypass flow control arrangement of centrifugal pump and a diaphragm type dosing pump. Similar heads and flow rates were attainable using the bypass control system compared to the diaphragm dosing pump, but using relatively more energy. Geometrical optimization of the centrifugal pump impeller was further carried out to make the bypass flow arrangement more energy efficient. Although both the systems run at low overall efficiencies but the capital cost could be reduced by about 87% compared to the dosing pump. The savings in capital investment and lower maintenance cost very significantly exceeds the relatively higher energy cost of the bypass system. This technique can be used as a cost effective solution for

  5. Smart Card Payment metering gas and electricity

    Energy Technology Data Exchange (ETDEWEB)

    Lee, D.L. [Landis and Gyr (United Kingdom) Ltd., Telford, (United Kingdom); Kriby, R. [Midlands Electricity plc, Kingswinford, (United Kingdom)

    1995-12-31

    Utilities, both gas and electricity, require and operate a variety of regular payment facilities. The range used by any particular utility is primarily a result of history and usually reflects the maturity of customer car and/or regulatory policies. This paper outlines the use of smart card metering, not to be confused with pre-payment metering, which establishes an enhanced level of service to both the customer and utility through the implementation of a simple 2 way communication system. The infrastructure of the smart card system is similar to that used for a token based system, with the smart card used to replace the token for credit transfer to the meter. It involves the use of a customer card which is credited from a Point of Sale (POS), along with the latest tariff details and any messages specific for that customer. These in turn are transferred to the meter when the card is inserted. The current meter readings, readings taken at a particular time and date, and meter status messages are written back to the card for transfer to the POS when credit is next purchased. In the future this infrastructure will be needed irrespective of advances in metering technology, and the Smart card is a secure and convenient way of ensuring correct customer identification and integrity of data. Possibilities are envisaged to extend the use of the system into other payment areas as well as being able to support innovative payment methods in the future. The response from customers, regulatory and welfare bodies, and the staff of the utility is extremely positive and the future of payment systems is considered to be secure in smart card technology. (author).

  6. Age as a risk factor for the disruption of cognitive performance by exposure to the types of radiation encounted on exploratory class missions to other planets

    Science.gov (United States)

    Exposure to the types of radiation encountered in space (particles of high energy and charge [HZE particles]) produces changes in neurocognitive performance similar to those observed in the aged organism. As such, it is possible that there would be an interaction between the effects of exposure to ...

  7. Effect of Geranylgeranylacetone on Ultraviolet Radiation Type B-Induced Cataract in Heat-Shock Transcription Factor 1 Heterozygous Mouse.

    Science.gov (United States)

    Ogasawara, Satoshi; Hashizume, Kouhei; Okuno, Takashi; Imaizumi, Toshiyasu; Inomata, Yui; Tezuka, Yu; Sanbe, Atushi; Kurosaka, Daijiro

    2017-05-01

    We investigated whether heat-shock transcription factor 1 (HSF1) was involved in ultraviolet radiation type B (UVR-B)-induced lens opacity (cataract) using HSF1 heterozygous mice. We also examined the effects of geranylgeranylacetone (GGA), an inducer of heat-shock proteins via activation of HSF, on the UVR-B-induced cataract. Male HSF1+/- and WT mice were unilaterally exposed to UVR-B (total: 1200mJ) at 16 weeks of age. At 48 h after the last UVR-B irradiation, the lens was isolated and the induction of the cataract was quantified as the cataract area ratio (opacity area/anterior capsule). GGA was orally administered at a dosage of 500 mg/kg once a day for two days before the first UVR-B exposure until the end of the experiment (21days in total). The HSF1 expression was more greatly decreased in the lens from HSF1+/- mice than in that from WT mice (p cataracts in the anterior capsule in both HSF1+/- and WT mice, while the opacity of the lens was markedly enhanced in HSF1+/- mice compared to that in WT mice(p (0.01). GGA treatment could prevent the induction of lens opacity by UVR-B exposure in both WT and HSF1+/- mice as compared with the non-administration group (p cataracts, possibly via regulation of HSPs such as HSP25.

  8. Anti-Theft Automatic Metering Interface

    Directory of Open Access Journals (Sweden)

    Abhijeet Das

    2015-08-01

    Full Text Available Abstract Electricity is now more than a necessity and its need is increasing day by day resulting in power theft and power scarcity. The purpose of this project is to provide automatic control and monitoring of the Domestic Energy Meter enabling the Electricity Department to read meter readings without anyone visiting each house and also prevent electricity theft .This can be achieved by the use of a Microcontroller Unit that continuously monitors and records the Energy Meter readings in its permanent memory location. This system also makes use of a GSM module for remote monitoring and control of Energy Meter with the help of an interfacing circuitry. The Microcontroller based system continuously records the readings and the live meter reading can be sent to the Electricity department after a count period or on request. This system also can be used to disconnect the power supply to the house in case of non-payment of electricity bills. The Substation will be the receiving end. The data received is fed to a microcontroller at the Substation which will automatically calculate the bill based on tariff provider and display it.

  9. Coincident bursts of auroral kilometric radiation and VLF emissions associted with a type 3 solar radio noise event

    Science.gov (United States)

    Rosenberg, T. J.; Singh, S.; Wu, C. S.; Labelle, J.; Treumann, R. A.; Inan, U. S.; Lanzerotti, L. J.

    1995-01-01

    This paper examines an isolated magnetospheric VLF/radio noise event that is highly suggestive of the triggering of terrestrial auroral kilometric radiation (AKR) bu solar type III radio emission and of a close relation between AKR and broadband hiss. The solar type III burst was measured on polar HF riometers and was coincident with local dayside VLF/LF noise emission bursts at South Pole station. It was also coincident with AKR bursts detected onthe AMPTE/IRM satellite, at the same magnetic local time as South Pole. On the basis of the close association of AKR and VLF bursts, and from geometric considerations relating to wave propagation, it is likely that the AKR source was on the dayside and on field lines near South Pole station. The general level of geomagnetic activity was very low. However, an isolated magnetic impulse event (MIE) accompanied by a riometer absorption pulse was in progress when all of the VLF/radio noise bursts occurred. The very close association of the typew III burst at HF with the AKR is consistent with external stimulation of the AKR, is different, more immediate,triggering process than that implied by Calvert (1981) is invoked. It is suggested here that some of the HF solar radiant energy may decay into waves with frequences comparable to those of the AKR by paraetric excitation or some other process, thus providing the few background photons required for the generation of AKR by the WU and Lee (1979) cyclotron maser instability. The AKR, perhaps by modifying the magnetospheric electron velocity distribution, might have produced the observed VLF emissions. Alternatively, the VLF emissions may have arisen from the same anisotropic and unstable electron distribution function responsible for the AKR.

  10. Atm heterozygous mice are more sensitive to radiation-induced cataracts than are their wild-type counterparts

    Science.gov (United States)

    Worgul, Basil V.; Smilenov, Lubomir; Brenner, David J.; Junk, Anna; Zhou, Wei; Hall, Eric J.

    2002-01-01

    It is important to know whether the human population includes genetically predisposed radiosensitive subsets. In vitro studies have shown that cells from individuals homozygous for ataxia telangiectasia (A-T) are much more radiosensitive than cells from unaffected individuals. Although cells heterozygous for the ATM gene (ATM(+/-)) may be slightly more radiosensitive in vitro, it remained to be determined whether the greater susceptibility of ATM(+/-) cells translates into an increased sensitivity for late effects in vivo, though there is a suggestion that radiotherapy patients that are heterozygous for the ATM gene may be more at risk of developing late normal tissue damage. We chose cataractogenesis in the lens as a means to assay for the effects of ATM deficiency in a late-responding tissue. One eye of wild-type, Atm heterozygous and homozygous knockout mice was exposed to 0.5-, 1.0-, 2.0-, or 4.0-Gy x rays. The animals were followed weekly for cataract development by conventional slit-lamp biomicroscopy. Cataract development in the animals of all three groups was strongly dependent on dose. The lenses of homozygous mice were the first to opacify at any given dose. Most important in the present context is that cataracts appeared earlier in the heterozygous versus wild-type animals. The data suggest that ATM heterozygotes in the human population may also be radiosensitive. This may influence the choice of individuals destined to be exposed to higher than normal doses of radiation, such as astronauts, and may also suggest that radiotherapy patients who are ATM heterozygotes could be predisposed to increased late normal tissue damage.

  11. Monte Carlo modeling provides accurate calibration factors for radionuclide activity meters.

    Science.gov (United States)

    Zagni, F; Cicoria, G; Lucconi, G; Infantino, A; Lodi, F; Marengo, M

    2014-12-01

    Accurate determination of calibration factors for radionuclide activity meters is crucial for quantitative studies and in the optimization step of radiation protection, as these detectors are widespread in radiopharmacy and nuclear medicine facilities. In this work we developed the Monte Carlo model of a widely used activity meter, using the Geant4 simulation toolkit. More precisely the "PENELOPE" EM physics models were employed. The model was validated by means of several certified sources, traceable to primary activity standards, and other sources locally standardized with spectrometry measurements, plus other experimental tests. Great care was taken in order to accurately reproduce the geometrical details of the gas chamber and the activity sources, each of which is different in shape and enclosed in a unique container. Both relative calibration factors and ionization current obtained with simulations were compared against experimental measurements; further tests were carried out, such as the comparison of the relative response of the chamber for a source placed at different positions. The results showed a satisfactory level of accuracy in the energy range of interest, with the discrepancies lower than 4% for all the tested parameters. This shows that an accurate Monte Carlo modeling of this type of detector is feasible using the low-energy physics models embedded in Geant4. The obtained Monte Carlo model establishes a powerful tool for first instance determination of new calibration factors for non-standard radionuclides, for custom containers, when a reference source is not available. Moreover, the model provides an experimental setup for further research and optimization with regards to materials and geometrical details of the measuring setup, such as the ionization chamber itself or the containers configuration. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Privacy friendly aggregation of smart meter readings, even when meters crash

    NARCIS (Netherlands)

    Hoepman, J.H.

    2017-01-01

    A well studied privacy problem in the area of smart grids is the question of how to aggregate the sum of a set of smart meter readings in a privacy friendly manner, i.e., in such a way that individual meter readings are not revealed to the adversary. Much less well studied is how to deal with

  13. An evaporation based digital microflow meter

    Science.gov (United States)

    Nie, C.; Frijns, A. J. H.; Mandamparambil, R.; Zevenbergen, M. A. G.; den Toonder, J. M. J.

    2015-11-01

    In this work, we present a digital microflow meter operating in the range 30-250 nl min-1 for water. The principle is based on determining the evaporation rate of the liquid via reading the number of wetted pore array structures in a microfluidic system, through which continuous evaporation takes place. A proof-of-principle device of the digital flow meter was designed, fabricated, and tested. The device was built on foil-based technology. In the proof-of-principle experiments, good agreement was found between set flow rates and the evaporation rates estimated from reading the number of wetted pore structures. The measurement range of the digital flow meter can be tuned and extended in a straightforward manner by changing the pore structure of the device.

  14. Coordinated Ramp Metering and Intersection Signal Control

    Directory of Open Access Journals (Sweden)

    Dongyan Su

    2014-06-01

    Full Text Available The operations of freeway ramp metering and urban traffic network signal control are independent in most areas. Such situation may cause some conflict between traffic streams of the two subsystems, or, at least, their dynamic interactions have not been taken into account from an overall system viewpoint. Traffic performance can be improved if the controls of these two subnetworks are integrated. This paper proposes a novel signal control strategy for the feeding intersection and a coordination strategy for integrating it with the corresponding freeway onramp metering. UP ALINEA with queue-overwrite is used for the ramp metering. A signal optimization, which takes into account the available ramp space and traffic demand, is developed for intersection signal control. A calibrated micro-simulation is used to compare the proposed control/coordination strategies and current control plans in the field. Simulation result shows that, even though the overall system performance only gets a marginal improvement, intersection delay reduces significantly.

  15. IMPORTANT: Fluke is recalling Digital Clamp Meters

    CERN Multimedia

    2013-01-01

    Fluke is voluntarily recalling four models of Digital Clamp Meters: Fluke 373, 374, 375 and 376. If you own one of these clamp meters, please stop using it and send it back to Fluke for repair even if you have not experienced problems.   Description of the problem: "The printed circuit assembly may not be properly fastened to the test lead input jack. This may result in inaccurate voltage readings, including a low or no-voltage reading on a circuit energised with a hazardous voltage, presenting a shock, electrocution or thermal burn hazard." To determine if your clamp meter is affected by this recall notice, and for more information, click here.

  16. A Dedicated Mixture Model for Clustering Smart Meter Data: Identification and Analysis of Electricity Consumption Behaviors

    OpenAIRE

    Fateh Nassim Melzi; Allou Same; Mohamed Haykel Zayani; Latifa Oukhellou

    2017-01-01

    The large amount of data collected by smart meters is a valuable resource that can be used to better understand consumer behavior and optimize electricity consumption in cities. This paper presents an unsupervised classification approach for extracting typical consumption patterns from data generated by smart electric meters. The proposed approach is based on a constrained Gaussian mixture model whose parameters vary according to the day type (weekday, Saturday or Sunday). The proposed method...

  17. Genome-wide transcriptome profiling of ROS scavenging and signal transduction pathways in rice (Oryza sativa L.) in response to different types of ionizing radiation.

    Science.gov (United States)

    Kim, Sun-Hee; Song, Mira; Lee, Kyung Jun; Hwang, Sun-Goo; Jang, Cheol Sung; Kim, Jin-Baek; Kim, Sang Hoon; Ha, Bo-Keun; Kang, Si-Yong; Kim, Dong Sub

    2012-12-01

    Ionizing radiation directly and indirectly affects gene expression within the plant genome. To access the antioxidant response of rice to different types of ionizing radiation, rice seeds were exposed to gamma-ray, cosmic-ray and ion beam radiation. Exposure to ionizing radiation dramatically decreased the shoot length in all plants but not the root length compared with a non-irradiated plant. Electron spin resonance, confirmed that the number of free radicals in cell was greatly increased by different types of ionizing radiation. The measurement of the MDA, chlorophyll, carotenoids contents and activity of antioxidant enzymes revealed that gamma-ray and cosmic-ray, but not ion beam, ionization deceased chlorophyll and carotenoids contents, while all three ionization treatments increased the activities of peroxidase, ascorbate peroxidase, and superoxide dismutase compared with the non-irradiated plants. Microarray analysis using Affymetrix GeneChip was used to establish the gene transcript profiles of rice genes regarding ROS scavenging and signal transduction pathways after ionization treatment. Many of the rice genes involved in ROS scavenging and signal transduction pathways showed induction or repression that had increased more than twofold after ionization treatment. In particular, genes associated with electron transport, such as NADPH oxidase-like and alternative oxidase, were often down-regulated by more than twofold in response to the ionization treatments. In our transcriptomic profile analysis, we confirmed that the expression of rice genes associated with ROS scavenging and signal transduction pathways was induced or repressed to different degrees by the different types of ionizing radiations, as in other environmental stresses.

  18. Energy Renovation of Buildings Utilizing the U-value Meter, a New Heat Loss Measuring Device

    OpenAIRE

    Lars Schiøtt Sørensen

    2010-01-01

    A new device with the ability to measure heat loss from building facades is proposed. Yet to be commercially developed, the U-value Meter can be used as stand-alone apparatus, or in combination with thermographic-equipment. The U-value meter complements thermographs, which only reproduce surface temperature and not the heat loss distribution. There is need for a device that measures the heat loss in a quantitative manner. Convective as well as radiative heat losses are captured and measured w...

  19. Miniature, high efficiency transducers for use in ultrasonic flow meters

    Science.gov (United States)

    Saikia, Meghna

    This thesis is concerned with the development of a new type of miniature, high efficiency transducer for use in ultrasonic flow meters. The proposed transducer consists of a thin plate of a suitable piezoelectric material on which an inter-digital transducer is fabricated for the generation and detection of plate acoustic waves. When immersed in a fluid medium, this device can convert energy from plate acoustic waves (PAWs) into bulk acoustic waves (BAWs) and vice versa. It is shown that this mode coupling principle can be used to realize efficient transducers for use in ultrasonic flow meters. This transducer can be mounted flush with the walls of the pipe through which fluid is flowing, resulting in minimal disturbance of fluid flow. A prototype flow cell using these transducers has been designed and fabricated. The characteristics of this device have been measured over water flow rates varying from 0 to 7.5 liters per minute and found to be in good agreement with theory. Another attractive property of the new transducers is that they can be used to realize remotely read, passive, wireless flow meters. Details of methods that can be used to develop this wireless capability are described. The research carried out in this thesis has applications in several other areas such as ultrasonic nondestructive evaluation (NDE), noncontact or air coupled ultrasonics, and for developing wireless capability in a variety of other acoustic wave sensors.

  20. Radiation risk models for all solid cancers other than those types of cancer requiring individual assessments after a nuclear accident

    Energy Technology Data Exchange (ETDEWEB)

    Walsh, Linda [Federal Office for Radiation Protection, Department ' ' Radiation Protection and Health' ' , Oberschleissheim (Germany); University of Zurich, Medical Physics Group, Institute of Physics, Zurich (Switzerland); Zhang, Wei [Public Health England, Centre for Radiation, Chemical and Environmental Hazards, Oxford (United Kingdom)

    2016-03-15

    In the assessment of health risks after nuclear accidents, some health consequences require special attention. For example, in their 2013 report on health risk assessment after the Fukushima nuclear accident, the World Health Organisation (WHO) panel of experts considered risks of breast cancer, thyroid cancer and leukaemia. For these specific cancer types, use was made of already published excess relative risk (ERR) and excess absolute risk (EAR) models for radiation-related cancer incidence fitted to the epidemiological data from the Japanese A-bomb Life Span Study (LSS). However, it was also considered important to assess all other types of solid cancer together and the WHO, in their above-mentioned report, stated ''No model to calculate the risk for all other solid cancer excluding breast and thyroid cancer risks is available from the LSS data''. Applying the LSS models for all solid cancers along with the models for the specific sites means that some cancers have an overlap in the risk evaluations. Thus, calculating the total solid cancer risk plus the breast cancer risk plus the thyroid cancer risk can overestimate the total risk by several per cent. Therefore, the purpose of this paper was to publish the required models for all other solid cancers, i.e. all solid cancers other than those types of cancer requiring special attention after a nuclear accident. The new models presented here have been fitted to the same LSS data set from which the risks provided by the WHO were derived. Although it is known already that the EAR and ERR effect modifications by sex are statistically significant for the outcome ''all solid cancer'', it is shown here that sex modification is not statistically significant for the outcome ''all solid cancer other than thyroid and breast cancer''. It is also shown here that the sex-averaged solid cancer risks with and without the sex modification are very similar once breast and

  1. Preliminary investigation of the ambient radiation levels of mining ...

    African Journals Online (AJOL)

    The study of the ambient radiation levels around some mining sites in Benue State has been carried out using radiation meters; Inspector 06250 and Dose Meter 6150AD. A total of four mining sites were selected for measurements. These sites include the Guma salt mine, Makurdi clay mine, Mkar quarry in Gboko and the ...

  2. Assessment of exposure to ionizing radiation at selected mining ...

    African Journals Online (AJOL)

    This paper investigated the levels of ionizing radiation at selected mining sites in Nasarawa State, Nigeria. Inspector alert nuclear radiation meter (S.E. International, USA SN: 35440) was used for these assessments. The meter was held at the abdominal level (about 1 m above ground level) and readings were taken in ...

  3. Liquid metal Flow Meter - Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, C.; Hoogendoom, S.; Hudson, B.; Prince, J.; Teichert, K.; Wood, J.; Chase, K.

    2007-01-30

    Measuring the flow of liquid metal presents serious challenges. Current commercially-available flow meters use ultrasonic, electromagnetic, and other technologies to measure flow, but are inadequate for liquid metal flow measurement because of the high temperatures required by most liquid metals. As a result of the reactivity and high temperatures of most liquid metals, corrosion and leakage become very serious safety concerns. The purpose of this project is to develop a flow meter for Lockheed Martin that measures the flow rate of molten metal in a conduit.

  4. A comparative study on the metering accuracy for given installation conditions of metering facility

    Energy Technology Data Exchange (ETDEWEB)

    Her, Jae Young; Lee, Seung Jun; Ha, Young Cheol; Ahn, Seung Hee; Lee, Cheol Gu [R and D Center, Korea Gas Co., (Korea)

    1999-12-01

    The object of this study is to improve metering facilities of Korea Gas Corporation(KOGAS) metering station which are being operated in unfavorable straight pipe length condition (metropolitan area). For experiment, a test facilities was modeled based on Dogsan metering station (one of KOGAS metering stations) which has the most unfavorable conditions in metropolitan area. The test facilities was set up in Jungdong metering station (one of KOGAS metering stations) supplying natural gas to a power plant and city gas companies. The tests were performed with flowconditioner which was installed in the former straight pipe of a turbine meter and an Orifice meter, and the tests keep going with changing both diameter ratio({beta} = d/D) and flowrate(Q{sub v}). In other words, the tests were performed according to flowrate change for fixed diameter ratio. After the test was completed, the diameter ratio was increased by 0.1 and the same procedures were conducted again. The test was conducted for diameter ratio from 0.3 to 0.7. For Orifice meter, the error showed 0.4 %(Test maximum flowrate=3,030 Nm{sup 3}/h) and 0.8 %(Test maximum flowrate=9,204 Nm{sup 3}/h) for {beta}=0.3 and 0.7, respectively. For Turbine meter, the error showed -0.5 %(Test maximum flowrate=3,030 Nm{sup 3}/h) and -0.1 %(Test maximum flowrate=9,204 Nm{sup 3}/h) for {beta}=0.3 and 0.7, respectively. 44 refs., 32 figs., 27 tabs.

  5. Development of a wavelength-separated type scintillator with optical fiber (SOF) dosimeter to compensate for the Cerenkov radiation effect.

    Science.gov (United States)

    Ishikawa, Masayori; Nagase, Naomi; Matsuura, Taeko; Hiratsuka, Junichi; Suzuki, Ryusuke; Miyamoto, Naoki; Sutherland, Kenneth Lee; Fujita, Katsuhisa; Shirato, Hiroki

    2015-03-01

    The scintillator with optical fiber (SOF) dosimeter consists of a miniature scintillator mounted on the tip of an optical fiber. The scintillator of the current SOF dosimeter is a 1-mm diameter hemisphere. For a scintillation dosimeter coupled with an optical fiber, measurement accuracy is influenced by signals due to Cerenkov radiation in the optical fiber. We have implemented a spectral filtering technique for compensating for the Cerenkov radiation effect specifically for our plastic scintillator-based dosimeter, using a wavelength-separated counting method. A dichroic mirror was used for separating input light signals. Individual signal counting was performed for high- and low-wavelength light signals. To confirm the accuracy, measurements with various amounts of Cerenkov radiation were performed by changing the incident direction while keeping the Ir-192 source-to-dosimeter distance constant, resulting in a fluctuation of Radiation Research Society and Japanese Society for Radiation Oncology.

  6. Advances in the project about Pin type silicon radiation detectors; Avances en el proyecto sobre detectores de radiacion de silicio tipo PIN

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez F, J. [Instituto Nacional de Investigaciones Nucleares, Laboratorio de Detectores de Radiacion, A.P. 18-1027, 11801 Mexico D.F. (Mexico); Cerdeira, A.; Aceves, M.; Diaz, A.; Estrada, M.; Rosales, P.; Cabal, A.E.; Montano L, M.; Leyva, A

    1998-07-01

    The obtained advances in the collaboration project ININ-CINVESTAV about development of Pin type semiconductor radiation detectors here are presented. It has been characterized the response to different types of radiation made in CINVESTAV and INAOE. Measurements have been realized with different types of sensitive to charge preamplifiers determining the main characteristics which must be executed to be able to be employed with low capacitance detectors. As applications it has been possible to measure the irradiation time in a mammography machine and X-ray energy spectra have been obtained in the order of 14 KeV, with 4 KeV at ambient temperature. The future actions of project have been indicated and the possible applications of these detectors. (Author)

  7. 49 CFR 192.353 - Customer meters and regulators: Location.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Customer meters and regulators: Location. 192.353... TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Customer Meters, Service Regulators, and Service Lines § 192.353 Customer meters and regulators: Location. (a) Each meter and service...

  8. Robust Meter Network for Water Distribution Pipe Burst Detection

    Directory of Open Access Journals (Sweden)

    Donghwi Jung

    2017-10-01

    Full Text Available A meter network is a set of meters installed throughout a water distribution system to measure system variables, such as the pipe flow rate and pressure. In the current hyper-connected world, meter networks are being exposed to meter failure conditions, such as malfunction of the meter’s physical system and communication system failure. Therefore, a meter network’s robustness should be secured for reliable provision of informative meter data. This paper introduces a multi-objective optimal meter placement model that maximizes the detection probability, minimizes false alarms, and maximizes the robustness of a meter network given a predefined number of meters. A meter network’s robustness is defined as its ability to consistently provide quality data in the event of meter failure. Based on a single-meter failure simulation, a robustness indicator for the meter network is introduced and maximized as the third objective of the proposed model. The proposed model was applied to the Austin network to determine the independent placement of pipe flow and pressure meters with three or five available meters. The results showed that the proposed model is a useful tool for determining meter locations to secure high detectability and robustness.

  9. Development of a pressure based vortex-shedding meter: measuring unsteady mass-flow in variable density gases

    Science.gov (United States)

    Ford, C. L.; Winroth, M.; Alfredsson, P. H.

    2016-08-01

    An entirely pressure-based vortex-shedding meter has been designed for use in practical time-dependent flows. The meter is capable of measuring mass-flow rate in variable density gases in spite of the fact that fluid temperature is not directly measured. Unlike other vortex meters, a pressure based meter is incredibly robust and may be used in industrial type flows; an environment wholly unsuitable for hot-wires for example. The meter has been tested in a number of static and dynamic flow cases, across a range of mass-flow rates and pressures. The accuracy of the meter is typically better than about 3% in a static flow and resolves the fluctuating mass-flow with an accuracy that is better than or equivalent to a hot-wire method.

  10. Analysis of n-in-p type silicon detectors for high radiation environment with fast analogue and binary readout systems

    Energy Technology Data Exchange (ETDEWEB)

    Printz, Martin

    2016-01-22

    sensor technology and module design will be deployed. Silicon strip and macro-pixel sensors in the future CMS experiment will face a fluence of up to Φ=1 x 10{sup 15} n{sub eq}cm{sup -2}s{sup -1} after an integrated luminosity of 3000 fb{sup -1} and 10 years of operation in HL-LHC conditions. Therefore the radiation hardness of the sensors must guarantee high charge collection efficiency which degrades with increasing radiation damage. Therefore extensive radiation damage and charge collection studies have been exercised in order to find the most suitable sensor material and layout which will withstand the harsh operation environment. The key technology has been decided to be p-type substrate whereby electrons with a high mobility and less trapping effects are collected by the readout electrodes. However, this technology requires detailed investigations of the necessary isolation layer which prevents a build up of an accumulation layer below the sensor surface which would directly lead to a lower resolution of the tracker. Furthermore, an elevated particle or track density requires a higher granularity. Hence the strip length of the sensors and the strip pitch will be reduced resulting in more channels and as a direct consequence more data which has to be transmitted out of the tracker volume. In contrary to the current tracker, the signal level will be compared to a threshold by the new binary readout chip CBC and just the binary hit information will be processed to the next instance. In addition, the tracker will contribute to the global Level-1 trigger decision. The contribution will be achieved by the correlation logic of the binary readout chip which detects hits on two stacked sensors in one module. Depending on the particle curvature in the CMS 3.8 T magnetic field, the transverse momentum p{sub T} of the traversing particles is estimated on-chip and compared to a programable threshold. Simulations indicate, that rejecting hits from low momentum particles in the

  11. Radio-controlled automatic gas meter-reading system; Releve automatique de compteur par radio

    Energy Technology Data Exchange (ETDEWEB)

    Yasui, M. [Osaka Gas Co., Ltd (Japan); Ishikawa, K.; Fujiwara, J. [Tokyo Gas Co., Ltd. (Japan); Ichihashi, T. [Toho Gas Co., Ltd. (Japan)

    2000-07-01

    In Japan, an automatic gas meter-reading system is in operation, also incorporating the functions of monitoring for abnormalities in gas use and remote-controlled emergency gas supply shutoff. This system has been realized by linking microcomputer-controlled gas meters(It's called 'Intelligent gas mater') equipped with automatic shutoff mechanism to the gas utility company operation center via communication lines. While the present system uses cable communication lines, we of Tokyo Gas Co., Ltd., Osaka Gas Co., Ltd. and Toho Gas Co., Ltd., have jointly developed a new system based on radio communication. This paper introduces this new system. While radio-controlled meter-reading systems are used in many countries around the world solely for automatic meter reading, our recently developed system is also capable of monitoring for abnormalities in gas use and remote-controlled emergency gas supply shutoff, thanks to its almost real-time two-way communication function. The new system can serve for a period of ten years without recharging. It is also characterized by its applicability as different systems according to purposes: 1) conventional automatic meter-reading system (terminal network control unit or T-NCU), 2) large-scale radio-controlled meter-reading system, and 3) portable terminal-type radio-controlled meter-reading system. (authors)

  12. Effect of second phase on single phase flow meters in steam quality measurement

    Directory of Open Access Journals (Sweden)

    M Pusayatanont

    2016-04-01

    Full Text Available This paper presents results from an investigation of the two phase flow, especially liquid ingas phase, in most mainly used flow meter in steam industry namely differential pressuremeter is investigated. As in general, a flowmeter is designed and employed to measure flowrate of single phase fluid. There are many types of meter available in the market characterizeby their working principles, installed conditions and measured fluid. All meters representtheir accuracies under the single phase flow condition. However, when they are working inunusual conditions especially under multiphase flow, most meters lose their accuraciessignificantly even there is small amount of second phase introduced into the system. Tounderstand the deteriorated performance of the meter under two phase flow, additional studyon the effect the second phase on the meter is required.The laboratory experiment is set up to simulate the wet steam by flowing compressed airin the 2 inch pipe. Water droplet is generated by pressurized water flowing through a nozzleand then spayed into the system in range of 25% maximum by mass fraction. The signal fromeach flowmeter is collected by digital computer and analyzed using FFT and power spectrumdensity. The results show that the presence of the second phase in the system causes highfrequency fluctuation and causes significant error on meter reading. Flow manufacturersalways add low-pass filter circuit to remove this high frequency signal, however, this papershows that the high frequency signal in specific region is useful as it can be use to estimatedthe percentage of the second phase in the main phase system.

  13. Aerosol Therapy: Nebulizer vs Metered Dose Inhaler

    National Research Council Canada - National Science Library

    Newhouse, M; Dolovich, M

    1987-01-01

    ... aerosol generation using metered-dose inhalers. Previously, aerosol delivery by means of intermittent positive pressure breathing devices attached to nebulizers enjoyed unwarranted popularity for decades, only to be abandoned when convincing evidence became available that they were no better than nebulizers alone for administering bronchodilato...

  14. Pico meter metrology for the GAIA mission

    NARCIS (Netherlands)

    Meijer, E.A.; Nijenhuis, J.N.; Vink, R.J.P.; Kamphues, F.G.; Gielesen, W.L.M.; Coatantiec, C.

    2009-01-01

    To measure the relative motions of GAIA's telescopes, the angle between the telescopes is monitored by an all Silicon Carbide Basic Angle Monitoring subsystem (BAM OMA). TNO is developing this metrology system. The stability requirements for this metrology system go into the pico meter and pico

  15. An evaporation based digital microflow meter

    NARCIS (Netherlands)

    Nie, C; Frijns, A J H; Mandamparambil, R; Zevenbergen, M A G; den Toonder, J M J

    2015-01-01

    In this work, we present a digital microflow meter operating in the range 30-250 nl min-1 for water. The principle is based on determining the evaporation rate of the liquid via reading the number of wetted pore array structures in a microfluidic system, through which continuous evaporation takes

  16. Meter wavelength radio astronomy in Chile.

    Science.gov (United States)

    May, J.; Reyes, F.; Alvarez, H.; Aparici, J.; Carr, T.; Phillips, J.; Levy, J.; Lebo, G.

    Current meter-wavelength research at Maipu consists largely of a galactic survey for the southern sky, a search for secondary calibration sources, pulsar studies, a search for atmospheric pulses from Saturn, and the continuing investigation of Jovian S bursts above 30 MHz.

  17. Meter Designs Reduce Operation Costs for Industry

    Science.gov (United States)

    2013-01-01

    Marshall Space Flight Center collaborated with Quality Monitoring and Control (QMC) of Humble, Texas, through a Space Act Agreement to design a balanced flow meter for the Space Shuttle Program. QMC founded APlus-QMC LLC to commercialize the technology, which has contributed to 100 new jobs, approximately $250,000 in yearly sales, and saved customers an estimated $10 million.

  18. Educational Electrical Appliance Power Meter and Logger

    Science.gov (United States)

    Nunn, John

    2013-01-01

    The principles behind two different designs of inductive power meter are presented. They both make use of the microphone input of a computer which, together with a custom-written program, can record the instantaneous power of a domestic electrical appliance. The device can be built quickly and can be calibrated with reference to a known power…

  19. Smart wavelength meter for integrated photonics

    NARCIS (Netherlands)

    Benelajla, Meryem; Taballione, Caterina; Boller, Klaus J.

    2017-01-01

    Thermally tunable SiN waveguide microring resonators in connection with neural network readout algorithms appear promising for use as integrated optical wavelength meters. So far, we have observed long-term reliability and a temperature immunity of the readout across several degrees of ambient

  20. Assessment of the implementation regulations for smart meters; Beoordeling uitvoeringsregelingen Slimme Meter

    Energy Technology Data Exchange (ETDEWEB)

    Boekema, J.

    2011-03-15

    TNO (Netherlands) assessed whether the smart meter is reliable and future proof. By request of the Dutch Ministry of Economic Affairs, Agriculture and Innovation (ELI) an assessment was conducted of the requirements for smart meters and, as formulated in the Order in Council 'Decree on remotely readable metering devices', based on 48 tests regarding security, privacy and future stability. Taking into account a number of described recommendations, TNO deems the legislation and implementation schemes sufficient to allow for safe, reliable and future proof implementation of smart meters in the Netherlands. [Dutch] TNO heeft beoordeeld of de slimme meter betrouwbaar en toekomstvast is. Ten behoeve van het ministerie van Economische Zaken, Landbouw en Innovatie (ELI) zijn de eisen die aan slimme meters worden gesteld, en zoals verwoord in de AmvB 'Besluit op afstand uitleesbare meetinrichtingen', beoordeeld aan de hand van 48 toetsen over zekerheid (security), persoonlijke levenssfeer (privacy) en toekomstvastheid. Met inachtneming van een aantal omschreven aanbevelingen, vindt TNO wetgeving en uitvoeringsregelingen zodanig dat daarmee een veilige, betrouwbare en toekomstvaste slimme meter geimplementeerd kan worden in Nederland.

  1. Interfacing of high temperature Z-meter setup using python

    Science.gov (United States)

    Patel, Ashutosh; Sisodia, Shashank; Pandey, Sudhir K.

    2017-05-01

    In this work, we interface high temperature Z-meter setup to automize the whole measurement process. A program is built on open source programming language `Python' which convert the manual measurement process into fully automated process without any cost addition. Using this program, simultaneous measurement of Seebeck coefficient (α), thermal conductivity (κ) and electrical resistivity (ρ), are performed and using all three, figure-of-merit (ZT) is calculated. Developed program is verified by performing measurement over p-type Bi0.36Sb1.45Te3 sample and the data obtained are found to be in good agreement with the reported data.

  2. The KFM, A Homemade Yet Accurate and Dependable Fallout Meter

    Energy Technology Data Exchange (ETDEWEB)

    Kearny, C.H.

    2001-11-20

    The KFM is a homemade fallout meter that can be made using only materials, tools, and skills found in millions of American homes. It is an accurate and dependable electroscope-capacitor. The KFM, in conjunction with its attached table and a watch, is designed for use as a rate meter. Its attached table relates observed differences in the separations of its two leaves (before and after exposures at the listed time intervals) to the dose rates during exposures of these time intervals. In this manner dose rates from 30 mR/hr up to 43 R/hr can be determined with an accuracy of {+-}25%. A KFM can be charged with any one of the three expedient electrostatic charging devices described. Due to the use of anhydrite (made by heating gypsum from wallboard) inside a KFM and the expedient ''dry-bucket'' in which it can be charged when the air is very humid, this instrument always can be charged and used to obtain accurate measurements of gamma radiation no matter how high the relative humidity. The heart of this report is the step-by-step illustrated instructions for making and using a KFM. These instructions have been improved after each successive field test. The majority of the untrained test families, adequately motivated by cash bonuses offered for success and guided only by these written instructions, have succeeded in making and using a KFM. NOTE: ''The KFM, A Homemade Yet Accurate and Dependable Fallout Meter'', was published by Oak Ridge National Laboratory report in1979. Some of the materials originally suggested for suspending the leaves of the Kearny Fallout Meter (KFM) are no longer available. Because of changes in the manufacturing process, other materials (e.g., sewing thread, unwaxed dental floss) may not have the insulating capability to work properly. Oak Ridge National Laboratory has not tested any of the suggestions provided in the preface of the report, but they have been used by other groups. When using these

  3. EUV radiation from pinching discharges of magnetoplasma compressor type and its dependence on the dynamics of compression zone formation

    Science.gov (United States)

    Garkusha, I. E.; Cherednychenko, T. N.; Ladygina, M. S.; Makhlay, V. A.; Petrov, Yu V.; Solyakov, D. G.; Staltsov, V. V.; Yelisyeyev, D. V.; Hassanein, A.

    2014-05-01

    This paper is devoted to the investigation of plasma stream parameters and the intensity of extreme ultraviolet (EUV) radiation from the compression zone in various modes of operation of a magnetoplasma compressor (MPC). Two gases of different masses, either helium or argon, were used for the ignition of MPC discharge under the residual pressure. The plasma stream density along the axis and the EUV radiation energy were measured. It was shown that the compression zone position depends on the initial density of the residual gas. The EUV radiation energy was measured with a calibrated AXUV in the wavelength range of 12.2-15.8 nm. It was revealed that the radiation energy increased by 30-50% with decreasing initial gas pressure.

  4. Household Smart Water Metering in Spain: Insights from the Experience of Remote Meter Reading in Alicante

    National Research Council Canada - National Science Library

    Hug March; alvaro-Francisco Morote; Antonio-Manuel Rico; David Saurí

    2017-01-01

    .... Beyond reducing certain labor costs, such as those related to manual meter reading, such detailed and continuous flow of information is said to enhance network efficiency and improve water planning...

  5. Metering error quantification under voltage and current waveform distortion

    Science.gov (United States)

    Wang, Tao; Wang, Jia; Xie, Zhi; Zhang, Ran

    2017-09-01

    With integration of more and more renewable energies and distortion loads into power grid, the voltage and current waveform distortion results in metering error in the smart meters. Because of the negative effects on the metering accuracy and fairness, it is an important subject to study energy metering combined error. In this paper, after the comparing between metering theoretical value and real recorded value under different meter modes for linear and nonlinear loads, a quantification method of metering mode error is proposed under waveform distortion. Based on the metering and time-division multiplier principles, a quantification method of metering accuracy error is proposed also. Analyzing the mode error and accuracy error, a comprehensive error analysis method is presented which is suitable for new energy and nonlinear loads. The proposed method has been proved by simulation.

  6. RADIATION COUNTER

    Science.gov (United States)

    Goldsworthy, W.W.

    1958-02-01

    This patent relates to a radiation counter, and more particularly, to a scintillation counter having high uniform sensitivity over a wide area and capable of measuring alpha, beta, and gamma contamination over wide energy ranges, for use in quickly checking the contami-nation of personnel. Several photomultiplier tubes are disposed in parallel relationship with a light tight housing behind a wall of scintillation material. Mounted within the housing with the photomultipliers are circuit means for producing an audible sound for each pulse detected, and a range selector developing a voltage proportional to the repetition rate of the detected pulses and automatically altering its time constant when the voltage reaches a predetermined value, so that manual range adjustment of associated metering means is not required.

  7. Acceptance test of an activity meter to be used as reference in a calibration methodology establishment

    Energy Technology Data Exchange (ETDEWEB)

    Correa, Eduardo L.; Kuahara, Lilian T.; Potiens, Maria da Penha A., E-mail: educorrea1905@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2014-07-01

    The nuclear medicine is a medical physics area in which radiopharmaceuticals are used in diagnostic procedures. These radioactive elements are administered in the patient and the radiation emitted is detected by an equipment, that makes the body scan, connected to a computer software, and the image is constructed. In order to operate the nuclear medicine service must have calibrated radiation detectors. Thought, it does not exist, in Brazil, an activity meter calibration methodology, which causes many measurement uncertainties. The goal of this study is to present the acceptance test results of an activity meter to be used as reference in a new calibration methodology establishment. It was checked an activity meter Capintec, CRC-25R model, using three control sources ({sup 137}Cs, {sup 57}Co, {sup 133}Ba). The tests were based on the CNEN-NN 3.05 standard, the manufacturer manual, the TRS-454 and the TECDOC 602 and include: physical inspection, chamber voltage, zero adjustment, background response, data check and repeatability. The linearity and geometry tests could not be made, because the laboratory where the activity meter is located is not authorized to receive non-sealed radioactive sources. The equipment has presented a good behavior. All the results are in the range presented by national and international standards and the equipment is now being used in the laboratory and periodically passes through the quality control tests. (author)

  8. Fuel cell membrane hydration and fluid metering

    Science.gov (United States)

    Jones, Daniel O.; Walsh, Michael M.

    1999-01-01

    A hydration system includes fuel cell fluid flow plate(s) and injection port(s). Each plate has flow channel(s) with respective inlet(s) for receiving respective portion(s) of a given stream of reactant fluid for a fuel cell. Each injection port injects a portion of liquid water directly into its respective flow channel in order to mix its respective portion of liquid water with the corresponding portion of the stream. This serves to hydrate at least corresponding part(s) of a given membrane of the corresponding fuel cell(s). The hydration system may be augmented by a metering system including flow regulator(s). Each flow regulator meters an injecting at inlet(s) of each plate of respective portions of liquid into respective portion(s) of a given stream of fluid by corresponding injection port(s).

  9. Energy Theft in the Advanced Metering Infrastructure

    Science.gov (United States)

    McLaughlin, Stephen; Podkuiko, Dmitry; McDaniel, Patrick

    Global energy generation and delivery systems are transitioning to a new computerized "smart grid". One of the principle components of the smart grid is an advanced metering infrastructure (AMI). AMI replaces the analog meters with computerized systems that report usage over digital communication interfaces, e.g., phone lines. However, with this infrastructure comes new risk. In this paper, we consider adversary means of defrauding the electrical grid by manipulating AMI systems. We document the methods adversaries will use to attempt to manipulate energy usage data, and validate the viability of these attacks by performing penetration testing on commodity devices. Through these activities, we demonstrate that not only is theft still possible in AMI systems, but that current AMI devices introduce a myriad of new vectors for achieving it.

  10. The results of randomized controlled trial of low-dose radiation for wet-type age-related macular degeneration on a 1 year term basis

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-06-01

    Evaluation of low dose radiation therapy to the wet-type age-related macular degeneration (AMD) located at the fovea centralis. Patients were irradiated with 10 fractions of 2 Gy external beam or just observed. Between the treated (39) and untreated (31) cases, there was no significant difference in gender, age, initial visual acuity, or size of the neovascular membrane. With the follow-up of 12 months, the visual acuity was significantly well preserved and the size of the neovascular membrane was decreased. These results indicate that low dose irradiation is effective for the wet-type AMD of the stage we treated in the present study. (author)

  11. From Smart Metering to Smart Grid

    Science.gov (United States)

    Kukuča, Peter; Chrapčiak, Igor

    2016-06-01

    The paper deals with evaluation of measurements in electrical distribution systems aimed at better use of data provided by Smart Metering systems. The influence of individual components of apparent power on the power loss is calculated and results of measurements under real conditions are presented. The significance of difference between the traditional and the complex evaluation of the electricity consumption efficiency by means of different definitions of the power factor is illustrated.

  12. Fibre optic power meter calibration uncertainties

    CSIR Research Space (South Africa)

    Nel, M

    2010-06-01

    Full Text Available 2010 - EngineerIT Technical Fibre optic power meter calibration uncertainties by Mariesa Nel, NMISA and Bertus Theron, CSIR-Defence, Peace, Safety and Security This article discusses the determination of uncertainty contributions when performing a... and Instrumentation News EngineerIT - June 2010 41 Most of these uncertainty contributions can either be obtained from a calibration certificate, specifications, or empirical measurements. In the next two sections detail are given on how to determine...

  13. Medium Access Control for Thermal Energy Harvesting in Advanced Metering Infrastructures

    DEFF Research Database (Denmark)

    Vithanage, Madava D.; Fafoutis, Xenofon; Andersen, Claus Bo

    2013-01-01

    In this paper we investigate the feasibility of powering wireless metering devices, namely heat cost allocators, by thermal energy harvested from radiators. The goal is to take a first step toward the realization of Energy-Harvesting Advanced Metering Infrastructures (EH-AMIs). While traditional...... the potential energy that can be harvested from Low Surface Temperature (LST) radiators. The experiments are based on a developed Energy-Harvesting Heat Cost Allocator (EH-HCA) prototype. On the basis of this measured power budget, we model and analytically compare the currently used Medium Access Control (MAC......) scheme of an industrial case study (IMR+) to a MAC scheme specifically designed for energy harvesting systems (ODMAC). Our analytical comparison shows the efficiency of the latter, as well as its ability to adapt to harvested ambient energy....

  14. LANDFIRE (90m) Existing Vegetation Type

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This map depicts the distribution of existing vegetation types contained in the LANDFIRE dataset. All 30-meter EVT grids were resampled to 90-meter grids and merged...

  15. Monocyte galactose/N-acetylgalactosamine-specific C-type lectin receptor stimulant immunotherapy of an experimental glioma. Part II: combination with external radiation improves survival

    Directory of Open Access Journals (Sweden)

    Kushchayev SV

    2012-09-01

    Full Text Available Sergiy V Kushchayev,1 Tejas Sankar,1 Laura L Eggink,5,6 Yevgeniya S Kushchayeva,5 Philip C Wiener,1,5 J Kenneth Hoober,5,6 Jennifer Eschbacher,3 Ruolan Liu,2 Fu-Dong Shi,2 Mohammed G Abdelwahab,4 Adrienne C Scheck,4 Mark C Preul11Neurosurgery Research Laboratory, 2Neuroimmunology Laboratory, 3Department of Pathology, 4Neurooncology Research, Barrow Neurological Institute, St Joseph's Hospital and Medical Center, Phoenix, 5School of Life Sciences, Arizona State University, Tempe, 6Susavion Biosciences, Inc, Tempe, AZ, USABackground: A peptide mimetic of a ligand for the galactose/N-acetylgalactosamine-specific C-type lectin receptors (GCLR exhibited monocyte-stimulating activity, but did not extend survival when applied alone against a syngeneic murine malignant glioma. In this study, the combined effect of GCLRP with radiation was investigated.Methods: C57BL/6 mice underwent stereotactic intracranial implantation of GL261 glioma cells. Animals were grouped based on randomized tumor size by magnetic resonance imaging on day seven. One group that received cranial radiation (4 Gy on days seven and nine only were compared with animals treated with radiation and GCLRP (4 Gy on days seven and nine combined with subcutaneous injection of 1 nmol/g on alternative days beginning on day seven. Magnetic resonance imaging was used to assess tumor growth and correlated with survival rate. Blood and brain tissues were analyzed with regard to tumor and contralateral hemisphere using fluorescence-activated cell sorting analysis, histology, and enzyme-linked immunosorbent assay.Results: GCLRP activated peripheral monocytes and was associated with increased blood precursors of dendritic cells. Mean survival increased (P < 0.001 and tumor size was smaller (P < 0.02 in the GCLRP + radiation group compared to the radiation-only group. Accumulation of dendritic cells in both the tumoral hemisphere (P < 0.005 and contralateral tumor-free hemisphere (P< 0.01 was

  16. Magnetic resonance diffusion tensor imaging (MRDTI) of the optic nerve and optic radiations at 3T in children with neurofibromatosis type I (NF-1)

    Energy Technology Data Exchange (ETDEWEB)

    Filippi, Christopher G.; Nickerson, Joshua P. [University of Vermont School of Medicine-FAHC, Department of Radiology, Burlington, VT (United States); Bos, Aaron [University of Vermont School of Medicine, Burlington, VT (United States); Salmela, Michael B. [University of Minnesota School of Medicine, Department of Radiology, Minneapolis, MN (United States); Koski, Chris J. [James Madison University, Department of Political Sciences, Harrisonburg, VA (United States); Cauley, Keith A. [University of Massachusetts Memorial Medical Center, Department of Radiology, Worcester, MA (United States)

    2012-02-15

    Optic pathway glioma (OPG) is a characteristic hallmark of neurofibromatosis type I (NF-I). To evaluate the feasibility of magnetic resonance diffusion tensor imaging (MRDTI) at 3T to detect abnormalities of the optic nerves and optic radiations in children with NF-I. 3-T MRDTI was prospectively performed in 9 children with NF-I (7 boys, 2 girls, average age 7.8 years, range 3-17 years) and 44 controls (25 boys, 19 girls, average age 8.1 years, range 3-17 years). Fractional anisotropy (FA) and mean diffusivity were determined by region-of-interest analysis for the optic nerves and radiations. Statistical analysis compared controls to NF-I patients. Two NF-I patients had bilateral optic nerve gliomas, three had chiasmatic gliomas and four had unidentified neurofibromatosis objects (UNOs) along the optic nerve pathways. All NF-I patients had statistically significant decreases in FA and elevations in mean diffusivity in the optic nerves and radiations compared to age-matched controls. MRDTI can evaluate the optic pathways in children with NF-I. Statistically significant abnormalities were detected in the diffusion tensor metrics of the optic nerves and radiations in children with NF-I compared to age-matched controls. (orig.)

  17. An improved Ångström-type model for estimating solar radiation over the Tibetan Plateau

    Science.gov (United States)

    Sunshine- and temperature-based empirical models are widely used for solar radiation estimation over the world, but the coefficients of the models are mostly site-dependent. The coefficients are expected to vary more under complex terrain conditions than under flat terrains. To test this hypothesis,...

  18. Evaporation heat meters - increasing cost efficiency through the years - an analysis of market leaders. Economic efficiency assessment for heat metering; Verdunstungsprinzip - mit den Jahren immer guenstiger - Eine Analyse der marktfuehrenden Angebote. Wirtschaftlichkeitsvergleich fuer Heizkostenermittlung

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1998-08-20

    The current version of the HVO of 1989 is a well-established catalogue of rules for heat metering. It gives building owners and administrators a choice of three different types of heat meters: Heat meters by the evaporation principle, electronic heat meters, and Kompasst heat meters. (orig.) [Deutsch] Die heute geltende Fassung der HVO aus dem Jahr 1989 gibt den Verbrauchern ein bewaehrtes und rechtlich eindeutiges Regelwerk zur Messung des Waermeverbrauchs in die Hand. Zugleich stellt die HVO Eigentuemer und Verwaltungen von Immobilien, die privat oder gewerblich von mehr als zwei Parteien genutzt werden, vor die Entscheidung ueber eine Erfassungstechnik. Mit verdunstungsbasierten und elektronischen Heizkostenverteilern sowie Kompasst-Waermezaehlern stehen heute drei unterschiedliche Systeme zur Verfuegung, mit denen die Waermeverbrauchserfassung im Rahmen der jeweiligen baulichen und oertlichen Voraussetzungen durchgefuehrt werden kann. (orig.)

  19. Oncogenic K-Ras signals through epidermal growth factor receptor and wild-type H-Ras to promote radiation survival in pancreatic and colorectal carcinoma cells.

    Science.gov (United States)

    Cengel, Keith A; Voong, K Rahn; Chandrasekaran, Sanjay; Maggiorella, Laurence; Brunner, Thomas B; Stanbridge, Eric; Kao, Gary D; McKenna, W Gillies; Bernhard, Eric J

    2007-04-01

    Pancreatic and colorectal carcinomas frequently express oncogenic/mutant K-Ras that contributes to both tumorigenesis and clinically observed resistance to radiation treatment. We have previously shown that farnesyltransferase inhibitors (FTI) radiosensitize many pancreatic and colorectal cancer cell lines that express oncogenic K-ras at doses that inhibit the prenylation and activation of H-Ras but not K-Ras. In the present study, we have examined the mechanism of FTI-mediated radiosensitization in cell lines that express oncogenic K-Ras and found that wild-type H-Ras is a contributor to radiation survival in tumor cells that express oncogenic K-Ras. In these experiments, inhibiting the expression of oncogenic K-Ras, wild-type H-Ras, or epidermal growth factor receptor (EGFR) led to similar levels of radiosensitization as treatment with the FTI tipifarnib. Treatment with the EGFR inhibitor gefitinib led to similar levels of radiosensitization, and the combinations of tipifarnib or gefitinib plus inhibition of K-Ras, H-Ras, or EGFR expression did not provide additional radiosensitization compared with tipifarnib or gefitinib alone. Finally, supplementing culture medium with the EGFR ligand transforming growth factor alpha was able to reverse the radiosensitizing effect of inhibiting K-ras expression. Taken together, these findings suggest that EGFR-activated H-Ras signaling is initiated by oncogenic K-Ras to promote radiation survival in pancreatic and colorectal cancers.

  20. Oncogenic K-Ras Signals through Epidermal Growth Factor Receptor and Wild-Type H-Ras to Promote Radiation Survival in Pancreatic and Colorectal Carcinoma Cells1

    Science.gov (United States)

    Cengel, Keith A.; Voong, K. Rahn; Chandrasekaran, Sanjay; Maggiorella, Laurence; Brunner, Thomas B.; Stanbridge, Eric; Kao, Gary D.; McKenna, W. Gillies; Bernhard, Eric J.

    2007-01-01

    Pancreatic and colorectal carcinomas frequently express oncogenic/mutant K-Ras that contributes to both tumorigenesis and clinically observed resistance to radiation treatment. We have previously shown that farnesyltransferase inhibitors (FTI) radiosensitize many pancreatic and colorectal cancer cell lines that express oncogenic K-ras at doses that inhibit the prenylation and activation of H-Ras but not K-Ras. In the present study, we have examined the mechanism of FTI-mediated radiosensitization in cell lines that express oncogenic K-Ras and found that wild-type H-Ras is a contributor to radiation survival in tumor cells that express oncogenic K-Ras. In these experiments, inhibiting the expression of oncogenic K-Ras, wild-type H-Ras, or epidermal growth factor receptor (EGFR) led to similar levels of radiosensitization as treatment with the FTI tipifarnib. Treatment with the EGFR inhibitor gefitinib led to similar levels of radiosensitization, and the combinations of tipifarnib or gefitinib plus inhibition of K-Ras, H-Ras, or EGFR expression did not provide additional radiosensitization compared with tipifarnib or gefitinib alone. Finally, supplementing culture medium with the EGFR ligand transforming growth factor α was able to reverse the radiosensitizing effect of inhibiting K-ras expression. Taken together, these findings suggest that EGFR-activated H-Ras signaling is initiated by oncogenic K-Ras to promote radiation survival in pancreatic and colorectal cancers. PMID:17460778

  1. Effect of the Scattering Radiation in Air and Two Type of Slap Phantom between PMMA and the ISO Water Phantom for Personal Dosimeters Calibration

    Science.gov (United States)

    Kamwang, N.; Rungseesumran, T.; Saengchantr, D.; Monthonwattana, S.; Pungkun, V.

    2017-06-01

    The calibration of personal dosimeter to determine the quantities of the personal dose equivalent, Hp(d), is required to be placed on a suitable phantom in order to provide a reasonable approximation to the radiation backscattering properties as equivalent as part of body. The dosimeter which is worn on the trunk usually calibrated with slap phantom which recommended in ICRU 47 with dimension of 30 cm (w) x 30 cm (h) x 15 cm (t) PMMA slab phantom to achieve uniformity in calibration procedures, on the other hand the International Organization for Standardization (ISO), ISO 4037-3, proposed the ISO water slap phantom, with PMMA walls, same dimension but different wall thickness (front wall 2.5 mm and other side wall 10 mm thick) and fill with water. However, some laboratories are still calibrating a personal dosimeter in air in term of ambient dose equivalent, H*(d). This research study the effect of the scattering radiation in two type of those slap phantoms and in air, to calibrate two type of OSL (XA and LA) and electronic personal dosimeters. The X-ray and Cs-137 radiation field with the energy range from 33 to 662 keV were used. The results of this study will be discussed.

  2. Oncogenic K-Ras Signals through Epidermal Growth Factor Receptor and Wild-Type H-Ras to Promote Radiation Survival in Pancreatic and Colorectal Carcinoma Cells

    Directory of Open Access Journals (Sweden)

    Keith A. Cengel

    2007-04-01

    Full Text Available Pancreatic and colorectal carcinomas frequently express oncogenic/mutant K-Ras that contributes to both tumorigenesis and clinically observed resistance to radiation treatment. We have previously shown that farnesyltransferase inhibitors (FTI radiosensitize many pancreatic and colorectal cancer cell lines that express oncogenic K-ras at doses that inhibit the prenylation and activation of H-Ras but not K-Ras. In the present study, we have examined the mechanism of FTI-mediated radiosensitization in cell lines that express oncogenic K-Ras and found that wild-type H-Ras is a contributor to radiation survival in tumor cells that express oncogenic K-Ras. In these experiments, inhibiting the expression of oncogenic K-Ras, wild-type H-Ras, or epidermal growth factor receptor (EGFR led to similar levels of radiosensitization as treatment with the FTI tipifarnib. Treatment with the EGFR inhibitor gefitinib led to similar levels of radiosensitization, and the combinations of tipifarnib or gefitinib plus inhibition of K-Ras, H-Ras, or EGFR expression did not provide additional radiosensitization compared with tipifarnib or gefitinib alone. Finally, supplementing culture medium with the EGFR ligand transforming growth factor o was able to reverse the radiosensitizing effect of inhibiting K-ras expression. Taken together, these findings suggest that EGFRactivated H-Ras signaling is initiated by oncogenic K-Ras to promote radiation survival in pancreatic and colorectal cancers.

  3. Uncertainties in the Value of Bill Savings from Behind-the-Meter, Residential Photovoltaic Systems: The Roles of Electricity Market Conditions, Retail Rate Design, and Net Metering

    Science.gov (United States)

    Darghouth, Naim Richard

    three types of retail rates (a flat rate, a time-of-use rate, and real-time pricing) from these wholesale price profiles, I examine bill savings from PV generation for the ten wholesale market scenarios under net metering and an alternative to net metering where hourly excess PV generation is compensated at the wholesale price. Most generally, I challenge the common assertion that PV compensation is likely to stay constant (or rise) due to constant (or rising) retail rates, and find that future electricity market scenarios can drive substantial changes in residential retail rates and that these changes, in concert with variations in retail rate structures and PV compensation mechanisms, interact to place substantial uncertainty on the future value of bill savings from residential PV.

  4. Review and analysis of different types of radiation detectors for measurements in radiotherapy; Revision y analisis de diferentes tipos de detectores para medidas en radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Alonso Iracheta, L.; Gomez Martin, C.; Maravilla Limorte, M.; Bejar Navarro, M. J.; Capuz Suarez, B.; Colmenares Fernandez, R.; Moris Pablos, R.; Rot Sanjuan, M. J.

    2011-07-01

    Physical dosimetry is the set of procedures and techniques aimed at establishing the extent and dosimetric variables with characterized radiotherapy sources and equipment and is a topic of great interest in all areas of radiotherapy, including areas where performed dosimetry of small fields such as stereotactic radiotherapy (SRS), intensity Modulated Radiation Therapy (IMRT) and intraoperative radiotherapy (RIO). By reviewing the physics of large fields and small bundles of photons and high energy electrons, we observe that it is difficult to select a single detector that is optimal for all measures of interest: area factors (output factors), depth dose curves (PDD's) and beam profiles with minimal errors, This paper summarizes a literature review to assess which of the different types of detectors available today is suitable for characterizing a beam of radiation.

  5. Investigating water meter performance in developing countries: A ...

    African Journals Online (AJOL)

    2011-10-07

    Oct 7, 2011 ... refers to the ISO classification for water meters and indicates the ability of the meter to measure low flows. Class D meters have the greatest ability to measure low flows and Class A have the least ability. Pressure measurements were also carried out at the properties (using Hydreka Vistaplus pressure data ...

  6. 49 CFR 192.359 - Customer meter installations: Operating pressure.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Customer meter installations: Operating pressure... SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Customer Meters, Service Regulators, and Service Lines § 192.359 Customer meter installations: Operating pressure...

  7. 49 CFR 192.357 - Customer meters and regulators: Installation.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Customer meters and regulators: Installation. 192... SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Customer Meters, Service Regulators, and Service Lines § 192.357 Customer meters and regulators: Installation. (a...

  8. The disc pasture meter: Possible applications in grazing management.

    African Journals Online (AJOL)

    The disc meter is a simple inexpensive instrument which may be used to make rapid yield estimates of standing forage. Linear regression relationships between meter reading and pasture dry matter yield are usually fairly good, but these may be affected by a number of different factors. The meter should therefore be ...

  9. Studies on growth and toxin production of C. botulinum type E on cod homogenate treated with a combination of spices, sodium chloride and gamma-radiation

    Energy Technology Data Exchange (ETDEWEB)

    Siddiqui, A.K. (Atomic Energy Centre, Dacca (Bangladesh)); Ando, Y.; Karashimada, T.; Kameyama, K.

    1979-09-01

    Cod homogenates inoculated with spores of C. botulinum type E strain Erimo at 10/sup 2/ and 10/sup 4//g were treated with 1% and 2% sodium chloride, 0.25% each of mustard, garlic and turmeric and 0.3 Mrad ..gamma..-radiation either in single or combination treatments. The growth and toxin production of type E spores in the inoculated homogenates were followed at incubation temperatures of 30/sup 0/, 10/sup 0/ and 5/sup 0/C for 7, 28 and 56 days respectively. Growth and gas formation were noted in all the samples but type E toxin could not be detected. The reason for the absence of toxin in both the untreated and treated homogenates could not be ascertained. Inadequate detection method, unfavourable growth conditions in the homogenate and weak toxigenicity of the strain employed have been advanced as probable factors that contributed to the negative results on the toxin assay.

  10. Enclosure design for Thirty Meter Telescope

    Science.gov (United States)

    Loewen, N.; Breckenridge, C.; Vasiljevic, A.

    2008-07-01

    The design of the calotte enclosure for the Thirty-Meter Telescope is currently in the preliminary design phase. Key aspects of the design include an efficient structural/mechanical form, repetition of components, modular construction, and operational efficiency. This paper includes an overall description of the enclosure design, as well as a description of the major structural and mechanical subsystems. The enclosure incorporates features that influence the thermal and aerodynamic environment of the telescope including ventilation openings and wind deflecting features. Other key considerations of the preliminary design include the constructability and maintainability of a dynamic structure of this scale at a remote mountain site.

  11. Smart Metering. Synergies within medium voltage automation; Synergien durch Smart Metering. Automatisierung auf Mittelspannungsebene

    Energy Technology Data Exchange (ETDEWEB)

    Maas, Peter [IDS GmbH, Ettlingen (Germany)

    2010-11-15

    Transparent interdivisional system solutions are an indispensable and decisive precondition for the optimization of business processes. The implementation of a Smart Metering solution does not only provide data for billing purposes, but also renders important data for network operation. Synergies can be achieved through the use of a common infrastructure which covers both the needs of Smart Metering and network operation. An open architecture of the solution allows for the future integration of further services of the domains Smart Grid and Smart Home. (orig.)

  12. Synergisms between smart metering and smart grid; Synergien zwischen Smart Metering und Smart Grid

    Energy Technology Data Exchange (ETDEWEB)

    Maas, Peter [IDS GmbH, Ettlingen (Germany)

    2010-04-15

    With the implementation of a smart metering solution, it is not only possible to acquire consumption data for billing but also to acquire relevant data of the distribution grid for grid operation. There is still a wide gap between the actual condition and the target condition. Synergies result from the use of a common infrastructure which takes account both of the requirements of smart metering and of grid operation. An open architecture also enables the future integration of further applications of the fields of smart grid and smart home. (orig.)

  13. Long Island Smart Metering Pilot Project

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2012-03-30

    The Long Island Power Authority (LIPA) Smart Meter Pilots provided invaluable information and experience for future deployments of Advanced Metering Infrastructure (AMI), including the deployment planned as part of LIPA's Smart Grid Demonstration Project (DE-OE0000220). LIPA will incorporate lessons learned from this pilot in future deployments, including lessons relating to equipment performance specifications and testing, as well as equipment deployment and tracking issues. LIPA ultimately deployed three AMI technologies instead of the two that were originally contemplated. This enabled LIPA to evaluate multiple systems in field conditions with a relatively small number of meter installations. LIPA experienced a number of equipment and software issues that it did not anticipate, including issues relating to equipment integration, ability to upgrade firmware and software over the air (as opposed to physically interacting with every meter), and logistical challenges associated with tracking inventory and upgrade status of deployed meters. In addition to evaluating the technology, LIPA also piloted new Time-of-Use (TOU) rates to assess customer acceptance of time-differentiated pricing and to evaluate whether customers would respond by adjusting their activities from peak to non-peak periods. LIPA developed a marketing program to educate customers who received AMI in the pilot areas and to seek voluntary participation in TOU pricing. LIPA also guaranteed participating customers that, for their initial year on the rates, their electricity costs under the TOU rate would not exceed the amount they would have paid under the flat rates they would otherwise enjoy. 62 residential customers chose to participate in the TOU rates, and every one of them saved money during the first year. 61 of them also elected to stay on the TOU rate without the cost guarantee at the end of that year. The customer who chose not to continue on the rate was also the one who achieved the

  14. A hybrid ICT-solution for smart meter data analytics

    DEFF Research Database (Denmark)

    Liu, Xiufeng; Nielsen, Per Sieverts

    2016-01-01

    conditions and user information, which makes the data sets very sizable and the analytics complex. Data mining and emerging cloud computing technologies make collecting, processing, and analyzing the so-called big data possible. This paper proposes an innovative ICT-solution to streamline smart meter data...... analytics. The proposed solution offers an information integration pipeline for ingesting data from smart meters, a scalable platform for processing and mining big data sets, and a web portal for visualizing analytics results. The implemented system has a hybrid architecture of using Spark or Hive for big......Smart meters are increasingly used worldwide. Smart meters are the advanced meters capable of measuring energy consumption at a fine-grained time interval, e.g., every 15 min. Smart meter data are typically bundled with social economic data in analytics, such as meter geographic locations, weather...

  15. A hybrid ICT-solution for smart meter data analytics

    DEFF Research Database (Denmark)

    Liu, Xiufeng; Nielsen, Per Sieverts

    2016-01-01

    Smart meters are increasingly used worldwide. Smart meters are the advanced meters capable of measuring energy consumption at a fine-grained time interval, e.g., every 15 min. Smart meter data are typically bundled with social economic data in analytics, such as meter geographic locations, weather...... conditions and user information, which makes the data sets very sizable and the analytics complex. Data mining and emerging cloud computing technologies make collecting, processing, and analyzing the so-called big data possible. This paper proposes an innovative ICT-solution to streamline smart meter data...... analytics. The proposed solution offers an information integration pipeline for ingesting data from smart meters, a scalable platform for processing and mining big data sets, and a web portal for visualizing analytics results. The implemented system has a hybrid architecture of using Spark or Hive for big...

  16. Design and Study of a Low-Cost Laboratory Model Digital Wind Power Meter

    Science.gov (United States)

    Radhakrishnan, Rugmini; Karthika, S.

    2010-01-01

    A vane-type low-cost laboratory model anemometer cum power meter is designed and constructed for measuring low wind energy created from accelerating fluids. The constructed anemometer is a device which records the electrical power obtained by the conversion of wind power using a wind sensor coupled to a DC motor. It is designed for its…

  17. Exposure to electromagnetic fields from smart utility meters in GB; part I) laboratory measurements.

    Science.gov (United States)

    Peyman, Azadeh; Addison, Darren; Mee, Terry; Goiceanu, Cristian; Maslanyj, Myron; Mann, Simon

    2017-05-01

    Laboratory measurements of electric fields have been carried out around examples of smart meter devices used in Great Britain. The aim was to quantify exposure of people to radiofrequency signals emitted from smart meter devices operating at 2.4 GHz, and then to compare this with international (ICNIRP) health-related guidelines and with exposures from other telecommunication sources such as mobile phones and Wi-Fi devices. The angular distribution of the electric fields from a sample of 39 smart meter devices was measured in a controlled laboratory environment. The angular direction where the power density was greatest was identified and the equivalent isotropically radiated power was determined in the same direction. Finally, measurements were carried out as a function of distance at the angles where maximum field strengths were recorded around each device. The maximum equivalent power density measured during transmission around smart meter devices at 0.5 m and beyond was 15 mWm-2 , with an estimation of maximum duty factor of only 1%. One outlier device had a maximum power density of 91 mWm-2 . All power density measurements reported in this study were well below the 10 W m-2 ICNIRP reference level for the general public. Bioelectromagnetics. 2017;38:280-294. © 2017 Crown copyright. BIOELECTROMAGNETICS © 2017 Wiley Periodicals, Inc. © 2017 Crown copyright. BIOELECTROMAGNETICS © 2017 Wiley Periodicals, Inc.

  18. Peak expiratory flow at increased barometric pressure: comparison of peak flow meters and volumetric spirometer.

    Science.gov (United States)

    Thomas, P S; Ng, C; Bennett, M

    2000-01-01

    Increasing numbers of patients are receiving hyperbaric oxygen therapy as an intensive care treatment, some of whom have pre-existing airway obstruction. Spirometers are the ideal instruments for measuring airway obstruction, but peak flow meters are useful and versatile devices. The behaviour of both types of device was therefore studied in a hyperbaric unit under conditions of increased pressure. It is important to have a non-electrical indicator of airway obstruction, to minimize the fire risk in the hyperoxic environment. The hypothesis was tested that, assuming that dynamic resistance is unchanged, both the Wright's standard and mini-peak flow meters would over-read peak expiratory flow (PEF) under increased pressure when compared with a volumetric spirometer, as the latter is unaffected by air density. It was postulated that a correction factor could be derived so that PEF meters could be used in this setting. Seven normal subjects performed volume-dependent spirometry to derive PEF, and manoeuvres using both standard and mini PEF meters at sea level, under hyperbaric conditions at 303, 253 and 152 kPa (3, 2.5 and 1.5 atmospheres respectively; 1 atmosphere absolute=101.08 kPa), and again at sea level. There was a progressive and significant decline in PEF with increasing pressure as measured by the spirometer (69.46+/-0.8% baseline at 303 kPa compared with 101 kPa), while the PEF meters showed a progressive increase in their readings (an increase of 7.86+/-1.69% at 303 kPa with the mini PEF meter). Using these data points, a correction factor was derived which allows appropriate values to be calculated from the Wright's meter readings under these conditions.

  19. Ionizing radiation effect on different types of flours used in bakery technology; Efeito da radiacao ionizante em diferentes tipos de farinhas utilizadas em tecnologia de panificacao

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, Christian Alexandre Heinz Melsheimer

    2011-07-01

    In this work, an evaluation of the changes caused by ionizing radiation in different types and quantities of products rich in starch (wheat flour, cassava, rye, whole wheat, green banana pulp and maize) on rheological, technological, physical and texture characteristics was studied. The samples were irradiated in a {sup 60}Co source with doses up to 10kGy, and dose rate about 2kGy/h. It was studied the force and the extensibility of strong and weak wheat flours and the rheological behavior was observed for one, five and thirty days after irradiation. The technological characteristic studied for up to 1 month after irradiation, was the enzymatic activity of the irradiated, weak and strong flours. The physical characteristics: height, weight and moisture loss and texture of loaves made with a partial replacement (30%) of wheat flour by different irradiated flours was established. The results showed that with the increase of radiation dose there was an increase of enzymatic activity, especially for higher doses (9kGy). These results corroborate for the understanding that there would be no need of addition of enzymatic improvers for the bread confection. The height, weight, and loss of moisture from the products developed with different substitutions of flours used in the formulations, showed different behaviors. With an increasing of the radiation dose applied, there was an increase in the height of the loaves, as well as a reduced loss of moisture on the products developed with substitution of 30% of the wheat flour with irradiated wheat flour and pulp of green banana flour. From a technological standpoint, the enzymatic activity was not adversely affected by radiation. Considering the characteristics studied, the dose of 9kGy would be recommended seeking the production of loaves. Although the irradiation process is generally applied in the preservation of hygienic quality of food products, its use on different kinds of flours used in bread production may induce some

  20. Effects of low-dose ionising radiation on pituitary adenoma: is there a role for L-type calcium channel?

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Marcella Araugio; Santos, Raquel Gouvea dos [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN), Belo Horizonte, MG (Brazil). Lab. de Radiobiologia]. E-mail: santosr@cdtn.br

    2005-10-15

    Pituitary adenomas constitute about 6-18% of brain tumours in adults. Activation of voltage gated calcium currents can account for growth hormone over secretion in some GH-secreting pituitary adenomas that produce an acromegaly appearance and increase mortality. Ca{sup 2+} ions, as mediators of intracellular signalling, are crucial for the development of apoptosis. However, the role of [Ca{sup 2+}] in the development of apoptosis is ambiguous. In this study, the effects of low-dose ionising gamma radiation ({sup 60} Co) on rat pituitary adenoma cells survival and proliferation and the role of calcium channels on the apoptosis radio-induced were evaluated. Doses as low as 3 Gy were found to inhibit GH3 cell proliferation. Even though there was a significant number of live cells,168 hours following irradiation, they were not able to proliferate. The results indicate that the blockade of extracellular calcium influx through these channels does not interfere in the radiation-induced apoptosis in GH3 cells. (author)

  1. A Probabilistic Model of Meter Perception: Simulating Enculturation

    Directory of Open Access Journals (Sweden)

    Bastiaan van der Weij

    2017-05-01

    Full Text Available Enculturation is known to shape the perception of meter in music but this is not explicitly accounted for by current cognitive models of meter perception. We hypothesize that the induction of meter is a result of predictive coding: interpreting onsets in a rhythm relative to a periodic meter facilitates prediction of future onsets. Such prediction, we hypothesize, is based on previous exposure to rhythms. As such, predictive coding provides a possible explanation for the way meter perception is shaped by the cultural environment. Based on this hypothesis, we present a probabilistic model of meter perception that uses statistical properties of the relation between rhythm and meter to infer meter from quantized rhythms. We show that our model can successfully predict annotated time signatures from quantized rhythmic patterns derived from folk melodies. Furthermore, we show that by inferring meter, our model improves prediction of the onsets of future events compared to a similar probabilistic model that does not infer meter. Finally, as a proof of concept, we demonstrate how our model can be used in a simulation of enculturation. From the results of this simulation, we derive a class of rhythms that are likely to be interpreted differently by enculturated listeners with different histories of exposure to rhythms.

  2. Application of the correction factor for radiation qualityK{sub q} in dosimetry with pencil-type ionization chambers using a Tandem system

    Energy Technology Data Exchange (ETDEWEB)

    Fontes, Ladyjane Pereira; Potiens, Maria da Penha Albuquerque, E-mail: lpfontes@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-11-01

    The pencil-type ionization chamber widely used in computed tomography (CT) dosimetry, is a measuring instrument that has a cylindrical shape and provides uniform response independent of the angle of incidence of ionizing radiation. Calibration and measurements performed with the pencil-type ionization chamber are done in terms of Kerma product in air-length (P{sub k,l}) and values are given in Gy.cm. To obtain the values of (P{sub k,l}) during clinical measurements, the readings performed with the ionization chamber are multiplied by the calibration coefficient (N{sub k,l}) and the correction factor C for quality (K{sub q}) which are given in Calibration certificates of the chambers. The application of the correction factor for radiation quality K{sub q} is done as a function of the effective energy of the beam that is determined by the Half Value layer (HVL) calculation. In order to estimate the HVL values in this work, a Tandem system made up of cylindrical aluminum and PMMA absorber layers was used as a low cost and easy to apply method. From the Tandem curve, it was possible to construct the calibration curve and obtain the appropriate K{sub q} to the beam of the computed tomography equipment studied. (author)

  3. Aperture meter for the Large Hadron Collider

    CERN Document Server

    Müller, G J; Redaelli, S

    2011-01-01

    The control of the high intensity beams of the CERN Large Hadron Collider (LHC) is particular challenging and requires a good modeling of the machine and monitoring of various machine parameters. During operation it is crucial to ensure a minimal distance between the beam edge and the aperture of sensitive equipment, e.g. the superconductingmagnets, which in all cases must be in the shadowof the collimator’s that protect the machine. Possible dangerous situations must be detected as soon as possible. In order to provide the operator with information about the current machine bottlenecks an aperture meter application was developed based on the LHC online modeling toolchain. The calculation of available free aperture takes into account the best available optics and aperture model as well as the relevant beam measurements. This paper describes the design and integration of this application into the control environment and presents results of the usage in daily operation and from validation measurements.

  4. Commissioning subsystems of the 10 meter prototype

    Science.gov (United States)

    Prins, Nathan; Fricke, Tobin; Mow-Lowry, Conor; Hanke, Manuela

    2015-04-01

    The best attempts at detecting the elusive gravitational waves are with L-shaped interferometers. Over the summer of 2014, I helped install subsystems of the 10 meter prototype, a gravitational wave interferometer designed to reach the Standard Quantum Limit (SQL), at the Max Planck Institute for Gravitational Physics in Hannover, Germany through the University of Florida's International REU. While there, the frequency reference cavity was aligned and the mode matching the cavity began. We also worked on installing and testing the intensity stabilization servo, which consisted of an out-of-vacuum photodiode for each the in-loop and out-of-loop sensing that were being connected to the LIGO Control and Data System.

  5. Five meter diameter conical furlable antenna

    Science.gov (United States)

    Fortenberry, J. W.; Freeland, R. E.; Moore, D. M.

    1976-01-01

    An investigation was made to demonstrate that a 5-meter-diameter, furlable, conical reflector antenna utilizing a line source feed can be fabricated utilizing composite materials and to prove that the antenna can function mechanically and electrically as prototype flight hardware. The design, analysis, and testing of the antenna are described. An RF efficiency of 55% at 8.5 GHz and a surface error of 0.64 mm rms were chosen as basic design requirements. Actual test measurements yielded an efficiency of 53% (49.77 dB gain) and a surface error of 0.61 mm rms. Atmospherically induced corrosion of the reflector mesh resulted in the RF performance degradation. An assessment of the antenna as compared to the current state of the art technology was made. This assessment included cost, surface accuracy and RF performance, structural and mechanical characteristics, and possible applications.

  6. Smart meter deployment optimisation and its analysis for appliance load monitoring

    Directory of Open Access Journals (Sweden)

    Ahmed Shaharyar Khwaja

    2015-04-01

    Full Text Available In this study, the authors study the problem of smart meter deployment optimisation for appliance load monitoring, that is, to monitor a number of devices without any ambiguity using the minimum number of low-cost smart meters. The importance of this problem is due to the fact that the number of meters should be reduced to decrease the deployment cost, improve reliability and decrease congestion. In this way, in future, smart meters can provide additional information about the type and number of distinct devices connected, besides their normal functionalities concerned with providing overall energy measurements and their communication. The authors present two exact smart meter deployment optimisation algorithms, one based on exhaustive search and the other based on efficient implementation of the exhaustive search. They formulate the problem mathematically and present computational complexity analysis of their algorithms. Simulation scenarios show that for a typical number of home appliances, the efficient search method is significantly faster compared to the exhaustive search and can provide the same optimal solution. The authors also show the dependency of their method on the distribution of the load pattern that can potentially be in a typical household.

  7. The LBL 55-meter spherical grating monochromator at SSRL

    Science.gov (United States)

    McKinney, W. R.; Howells, M. R.; Lauritzen, T.; Chin, J.; DiGennaro, R.; Fong, E.; Gath, W.; Guigli, J.; Hogrefe, H.; Meneghetti, J.; Plate, D.; Heimann, P. A.; Terminello, L.; Ji, Z.; Shirley, D.; Senf, F.

    1990-05-01

    A 55 meter spherical grating monochromator has been completed at the Stanford Synchrotron Radiation Laboratory (SSRL). The monochromator includes a unique capability for water cooled gratings, and is presently operating with a fused silica grating from 180 to 820 eV. A resolution of 60 meV has been achieved at 400 eV, inferred from the linewidths of the nitrogen 1s-π∗ resonance. A photon flux of 4 × 10 10 photon/s has been observed at 440 eV and 40 mA ring current (and with 0.5 eV resolution). It is expected that this flux value will improve by a factor of approximately 10-30 when a full-performance condensing system is installed later this year. The optical and mechanical systems design of the Rowland Circle monochromator with moving entrance and exit slits is reviewed. The details of the laser interferometer encoded wavelength drive, the mounting of the water cooled gratings, and the mechanical design features which improve the stability and accuracy of the system are described. The alignment of the gratings, grating chamber, and slits is discussed.

  8. Development of a calibration methodology and tests of kerma area product meters; Desenvolvimento de uma metodologia de calibracao e testes de medidores de produto Kerma-Area

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Nathalia Almeida

    2013-07-01

    The quantity kerma area product (PKA) is important to establish reference levels in diagnostic radiology exams. This quantity can be obtained using a PKA meter. The use of such meters is essential to evaluate the radiation dose in radiological procedures and is a good indicator to make sure that the dose limit to the patient's skin doesn't exceed. Sometimes, these meters come fixed to X radiation equipment, which makes its calibration difficult. In this work, it was developed a methodology for calibration of PKA meters. The instrument used for this purpose was the Patient Dose Calibrator (PDC). It was developed to be used as a reference to check the calibration of PKA and air kerma meters that are used for dosimetry in patients and to verify the consistency and behavior of systems of automatic exposure control. Because it is a new equipment, which, in Brazil, is not yet used as reference equipment for calibration, it was also performed the quality control of this equipment with characterization tests, the calibration and an evaluation of the energy dependence. After the tests, it was proved that the PDC can be used as a reference instrument and that the calibration must be performed in situ, so that the characteristics of each X-ray equipment, where the PKA meters are used, are considered. The calibration was then performed with portable PKA meters and in an interventional radiology equipment that has a PKA meter fixed. The results were good and it was proved the need for calibration of these meters and the importance of in situ calibration with a reference meter. (author)

  9. Energy Renovation of Buildings Utilizing the U-value Meter, a New Heat Loss Measuring Device

    Directory of Open Access Journals (Sweden)

    Lars Schiøtt Sørensen

    2010-01-01

    Full Text Available A new device with the ability to measure heat loss from building facades is proposed. Yet to be commercially developed, the U-value Meter can be used as stand-alone apparatus, or in combination with thermographic-equipment. The U-value meter complements thermographs, which only reproduce surface temperature and not the heat loss distribution. There is need for a device that measures the heat loss in a quantitative manner. Convective as well as radiative heat losses are captured and measured with a five-layer thermal system. Heat losses are measured in the SI-unit W/m2K. The aim is to achieve more cost-effective building renovation, and provide a means to check the fulfillment of Building Regulation requirements with respect to stated U-values (heat transmission coefficients. In this way it should be possible to greatly reduce energy consumption of buildings.

  10. Method and apparatus for reading meters from a video image

    Science.gov (United States)

    Lewis, Trevor J.; Ferguson, Jeffrey J.

    1997-01-01

    A method and system to enable acquisition of data about an environment from one or more meters using video images. One or more meters are imaged by a video camera and the video signal is digitized. Then, each region of the digital image which corresponds to the indicator of the meter is calibrated and the video signal is analyzed to determine the value indicated by each meter indicator. Finally, from the value indicated by each meter indicator in the calibrated region, a meter reading is generated. The method and system offer the advantages of automatic data collection in a relatively non-intrusive manner without making any complicated or expensive electronic connections, and without requiring intensive manpower.

  11. Deducing Energy Consumer Behavior from Smart Meter Data

    DEFF Research Database (Denmark)

    Ebeid, Emad Samuel Malki; Heick, Rune; Jacobsen, Rune Hylsberg

    2017-01-01

    The ongoing upgrade of electricity meters to smart ones has opened a new market of intelligent services to analyze the recorded meter data. This paper introduces an open architecture and a unified framework for deducing user behavior from its smart main electricity meter data and presenting the r...... the recognized home appliances. The framework uses open standard interfaces for exchanging data. The framework has been validated through comprehensive experiments that are related to an European Smart Grid project.......The ongoing upgrade of electricity meters to smart ones has opened a new market of intelligent services to analyze the recorded meter data. This paper introduces an open architecture and a unified framework for deducing user behavior from its smart main electricity meter data and presenting...

  12. Smart Meter Data Analytics: Systems, Algorithms and Benchmarking

    DEFF Research Database (Denmark)

    Liu, Xiufeng; Golab, Lukasz; Golab, Wojciech

    2016-01-01

    Smart electricity meters have been replacing conventional meters worldwide, enabling automated collection of fine-grained (e.g., every 15 minutes or hourly) consumption data. A variety of smart meter analytics algorithms and applications have been proposed, mainly in the smart grid literature....... However, the focus has been on what can be done with the data rather than how to do it efficiently. In this paper, we examine smart meter analytics from a software performance perspective. First, we design a performance benchmark that includes common smart meter analytics tasks. These include off......-line feature extraction and model building as well a framework for on-line anomaly detection that we propose. Second, since obtaining real smart meter data is difficult due to privacy issues, we present an algorithm for generating large realistic data sets from a small seed of real data. Third, we implement...

  13. Advanced Metering Installations – A Perspective from Federal Sites

    Energy Technology Data Exchange (ETDEWEB)

    Earni, Shankar [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Technologies Area

    2016-05-02

    This report is intended to provide guidance to the United States Department of Energy (DOE) and other federal agencies to highlight some of the existing practices related to advanced building metering systems. This study identified some of the existing actions related to advanced meter data and proposes how advanced metered data can be employed to develop robust cost effective measurement and verification (M&V) strategies. This report proposes an integrated framework on how advanced meter data can be used to identify energy conservation opportunities and to develop proactive M&V strategies to ensure that the savings for energy projects are being realized. This information will help improve metering, feedback, and dashboard implementations for reducing energy use at DOE facilities, based on lessons learned from various advanced metering implementations.

  14. De Minimis Thresholds for Federal Building Metering Appropriateness

    Energy Technology Data Exchange (ETDEWEB)

    Henderson, Jordan W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-03-31

    The U.S. Department of Energy (DOE) is required by statute and Presidential Memorandum to establish guidelines for agencies to meter their Federal buildings for energy (electricity, natural gas, and steam) and water. See 42 U.S.C. § 8253(e). DOE issued guidance in February 2006 on the installation of electric meters in Federal buildings. A recent update to the 2006 guidance accounts for more current metering practices within the Federal Government. The updated metering guidance specifies that all Federal buildings shall be considered “appropriate” for energy or water metering unless identified for potential exclusion. In developing the updated guidance to carry out the statue, Congress also directed DOE to (among other things) establish exclusions from the metering requirements based on the de minimis quantity of energy use of a Federal building, industrial process, or structure. This paper discusses the method used to identify de minimis values.

  15. A review of net metering mechanism for electricity renewable energy sources

    Energy Technology Data Exchange (ETDEWEB)

    Poullikkas, Andreas; Kourtis, George; Hadjipaschalis, Ioannis [Electricity Authority of Cyprus, P.O. Box 24506, 1399 Nicosia (Cyprus)

    2013-07-01

    In this work, an overview of the net metering mechanism for renewable energy sources for power generation (RES-E) systems is carried out. In particular, the net metering concept is examined with its benefits and misconceptions. Furthermore, a survey of the current operational net metering schemes in different countries in the world, such as, in Europe, USA, Canada, Thailand and Australia, is carried out. The survey indicated that there are different net metering mechanisms depending on the particularities of each country (or state in the case of USA). Especially, in Europe, only five countries are using net metering in a very simple form, such as, any amount of energy produced by the eligible RES-E technology is compensated from the energy consumed by the RES-E producer, which results to either a less overall electricity bill or to an exception in payment energy taxes. In the USA and the USA territories, any customer’s net excess generation is credited to the customer’s next electricity bill for a 12-month billing cycle at various rates or via a combination between rates. The actual type of net excess generation (NEG) credit is decided by a number of set criteria, such as the type of RES-E technology, the RES-E capacity limit, the type of customer and the type of utility. Regarding any excess credit at the end of the 12-month billing cycle, this is either granted to the utilities, or carries over indefinitely to the customer’s next electricity bill, or is reconciled annually at any rate, or provides an option to the customer to choose between the last two options.

  16. Enhancing Observability in Distribution Grids using Smart Meter Data

    OpenAIRE

    Bhela, Siddharth; Kekatos, Vassilis; Veeramachaneni, Sriharsha

    2016-01-01

    Due to limited metering infrastructure, distribution grids are currently challenged by observability issues. On the other hand, smart meter data, including local voltage magnitudes and power injections, are communicated to the utility operator from grid buses with renewable generation and demand-response programs. This work employs grid data from metered buses towards inferring the underlying grid state. To this end, a coupled formulation of the power flow problem (CPF) is put forth. Exploiti...

  17. Development of a hand-held fast neutron survey meter.

    Science.gov (United States)

    Yoshida, T; Tsujimura, N; Yamano, T

    2011-07-01

    A neutron survey meter with a ZnS(Ag) scintillator to measure recoil protons was built. The detection probe weighs ~2 kg, therefore providing us with true portability. Performance tests exhibited satisfactory neutron dosimetry characteristics in unmoderated or lightly moderated fission neutron fields and in particular work environments at a mixed oxide fuel facility. This new survey meter will augment a routine of neutron monitoring that is inconveniently being carried out by moderator-based neutron survey meters.

  18. FUSION OF VENTURI AND ULTRASONIC FLOW METER FOR ENHANCED FLOW METER CHARACTERISTICS USING FUZZY LOGIC

    Directory of Open Access Journals (Sweden)

    K.V. Santhosh

    2015-04-01

    Full Text Available This paper proposes a technique for measurement of liquid flow using venturi and ultrasonic flow meter(UFM to have following objectives a to design a multi-sensor data fusion (MSDF architecture for using both the sensors, b improve sensitivity and linearity of venturi and ultrasonic flow meter, and c detect and diagnosis of faults in sensor if any. Fuzzy logic algorithm is used to fuse outputs of both the sensor and train the fuzzy block to produces output which has an improved characteristics in terms of both sensitivity and linearity. For identification of sensor faults a comparative test algorithm is designed. Once trained proposed technique is tested in real life, results show successful implementation of proposed objectives.

  19. Investigation and Comparison of Separate Meter-In Separate Meter-Out Control Strategies

    DEFF Research Database (Denmark)

    Pedersen, Henrik C.; Andersen, Torben Ole; Skoubo, Tobias

    2014-01-01

    . The possibility to independently control the meter-in and meter-out side not only increase the functionality of the system, but also opens up for better performance and/or lowered energy consumption. The focus of the current paper is therefore on investigation and comparison of what may be obtained using...... multivariable control strategies for SMISMO control of a single axis hydraulic system with a differential cylinder, when not taking other measures to improve performance. The paper first presents an experimentally verified model of the system considered, from which a linear model is derived. Based on the model......, the control strategies are discussed and severalH¥ controllers are designed, for which both simulation and experimental results are presented. The controllers are evaluated with regard to performance and robustness and compared to a simple SISO control. Based on the findings, the possibilities and limitations...

  20. Effects of low-dose ionising radiation on pituitary adenoma: is there a role for L-type calcium channel?

    Directory of Open Access Journals (Sweden)

    Marcella Araugio Soares

    2005-10-01

    Full Text Available Pituitary adenomas constitute about 6-18% of brain tumours in adults. Activation of voltage gated calcium currents can account for growth hormone oversecretion in some GH-secreting pituitary adenomas that produce an acromegaly appearance and increase mortality. Ca2+ ions, as mediators of intracellular signalling, are crucial for the development of apoptosis. However, the role of [Ca2+] in the development of apoptosis is ambiguous. In this study, the effects of low-dose ionising gamma radiation (60Co on rat pituitary adenoma cells survival and proliferation and the role of calcium channels on the apoptosis radio-induced were evaluated. Doses as low as 3 Gy were found to inhibit GH3 cell proliferation. Even though there was a significant number of live cells,168 hours following irradiation, they were not able to proliferate. The results indicate that the blockade of extracellular calcium influx through these channels does not interfere in the radiation-induced apoptosis in GH3 cells.Adenomas de pituitária constituem cerca de 6-18% dos tumores cerebrais em adultos. A ativação de correntes de cálcio dependentes de voltagem podem levar à super-excreção de hormônio do crescimento produzindo acromegalia e aumentando a mortalidade. Íons Ca2+ como mediadores de sinalização intracelular são cruciais no desenvolvimento da apoptose. No entanto, o papel da [Ca 2+] no desenvolvimento da apoptose é ambíguo. Neste estudo nós avaliamos os efeitos de baixas doses de radiação gama (60Co na sobrevivência e proliferação de células de adenoma de pituitária de rato e o papel do cálcio na apoptose radio-induzida. Nossos resultados mostraram que a dose de 3Gy foi suficiente para inibir a proliferação das células GH3. Apesar de existir um número significativo de células vivas após 168 horas do tratamento com radiação, elas não estavam aptas a proliferar. Nossos resultados também indicaram que bloqueio do influxo de cálcio extracelular n

  1. Development of simple band-spectral pyranometer and quantum meter using photovoltaic cells and bandpass filters

    Energy Technology Data Exchange (ETDEWEB)

    Bilguun, Amarsaikhan, E-mail: bilguun@pes.ee.tut.ac.jp; Nakaso, Tetsushi; Harigai, Toru; Suda, Yoshiyuki; Takikawa, Hirofumi, E-mail: takikawa@ee.tut.ac.jp [Toyohashi University of Technology, 1-1 Habarigaoka, Tempaku, Toyohashi 441-8580 (Japan); Tanoue, Hideto [Kitakyushu National College of Technology, 5-20-1, Kokuraminami, Kitakyushu, Fukuoka 802-0985 (Japan)

    2016-02-01

    In recent years, greenhouse automatic-control, based on the measurement of solar irradiance, has been attracting attention. This control is an effective method for improving crop production. In the agricultural field, it is necessary to measure Photon Flux Density (PFD), which is an important parameter in the promotion of plant growth. In particular, the PFD of Photosynthetically Active Radiation (PAR, 400-700 nm) and Plant Biologically Active Radiation (PBAR, 300-800 nm) have been discussed in agricultural plant science. The commercial quantum meter (QM, PAR meter) can only measure Photosynthetically Photon Flux Density (PPFD) which is the integrated PFD quantity on the PAR wavelength. In this research, a band-spectral pyranometer or quantum meter using PVs with optical bandpass filters for dividing the PBAR wavelength into 100 nm bands (five independent channels) was developed. Before field testing, calibration of the instruments was carried out using a solar simulator. Next, a field test was conducted in three differing weather conditions such as clear, partly cloudy and cloudy skies. As a result, it was found that the response rate of the developed pyranometer was faster by four seconds compared with the response rate of the commercial pyranometer. Moreover, the outputs of each channel in the developed pyranometer were very similar to the integrated outputs of the commercial spectroradiometer. It was confirmed that the solar irradiance could be measured in each band separately using the developed band-spectral pyranometer. It was indicated that the developed band-spectral pyranometer could also be used as a PV band-spectral quantum meter which is obtained by converting the band irradiance into band PFD.

  2. Collaborative Outbound Taxi Metering for Environmental Benefits Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This proposal addresses the concept of Collaborative Outbound Taxi Metering (COTM), which provides environmental benefits without sacrificing throughput. In current...

  3. A Scalable Smart Meter Data Generator Using Spark

    DEFF Research Database (Denmark)

    Iftikhar, Nadeem; Liu, Xiufeng; Danalachi, Sergiu

    2017-01-01

    Today, smart meters are being used worldwide. As a matter of fact smart meters produce large volumes of data. Thus, it is important for smart meter data management and analytics systems to process petabytes of data. Benchmarking and testing of these systems require scalable data, however, it can...... be challenging to get large data sets due to privacy and/or data protection regulations. This paper presents a scalable smart meter data generator using Spark that can generate realistic data sets. The proposed data generator is based on a supervised machine learning method that can generate data of any size...

  4. A Novel Smart Meter Controlling System with Dynamic IP Addresses

    DEFF Research Database (Denmark)

    Manembu, Pinrolinvic; Welang, Brammy; Kalua Lapu, Aditya

    2017-01-01

    Smart meters are the electronic devices for measuring energy consumption in real time. Usually, static public IP addresses are allocated to realize the point-to-point (P2P) communication and remote controlling for smart metering systems. This, however, restricts the wide deployment of smart meters......, due to the deficiency of public IP resources. This paper proposes a novel subscription-based communication architecture for the support of dynamic IP addresses and group controlling of smart meters. The paper evaluates the proposed architecture by comparing the traditional P2P architecture...

  5. An accurate and portable solid state neutron rem meter

    Energy Technology Data Exchange (ETDEWEB)

    Oakes, T.M. [Nuclear Science and Engineering Institute, University of Missouri, Columbia, MO (United States); Bellinger, S.L. [Department of Mechanical and Nuclear Engineering, Kansas State University, Manhattan, KS (United States); Miller, W.H. [Nuclear Science and Engineering Institute, University of Missouri, Columbia, MO (United States); Missouri University Research Reactor, Columbia, MO (United States); Myers, E.R. [Department of Physics, University of Missouri, Kansas City, MO (United States); Fronk, R.G.; Cooper, B.W [Department of Mechanical and Nuclear Engineering, Kansas State University, Manhattan, KS (United States); Sobering, T.J. [Electronics Design Laboratory, Kansas State University, KS (United States); Scott, P.R. [Department of Physics, University of Missouri, Kansas City, MO (United States); Ugorowski, P.; McGregor, D.S; Shultis, J.K. [Department of Mechanical and Nuclear Engineering, Kansas State University, Manhattan, KS (United States); Caruso, A.N., E-mail: carusoan@umkc.edu [Department of Physics, University of Missouri, Kansas City, MO (United States)

    2013-08-11

    Accurately resolving the ambient neutron dose equivalent spanning the thermal to 15 MeV energy range with a single configuration and lightweight instrument is desirable. This paper presents the design of a portable, high intrinsic efficiency, and accurate neutron rem meter whose energy-dependent response is electronically adjusted to a chosen neutron dose equivalent standard. The instrument may be classified as a moderating type neutron spectrometer, based on an adaptation to the classical Bonner sphere and position sensitive long counter, which, simultaneously counts thermalized neutrons by high thermal efficiency solid state neutron detectors. The use of multiple detectors and moderator arranged along an axis of symmetry (e.g., long axis of a cylinder) with known neutron-slowing properties allows for the construction of a linear combination of responses that approximate the ambient neutron dose equivalent. Variations on the detector configuration are investigated via Monte Carlo N-Particle simulations to minimize the total instrument mass while maintaining acceptable response accuracy—a dose error less than 15% for bare {sup 252}Cf, bare AmBe, an epi-thermal and mixed monoenergetic sources is found at less than 4.5 kg moderator mass in all studied cases. A comparison of the energy dependent dose equivalent response and resultant energy dependent dose equivalent error of the present dosimeter to commercially-available portable rem meters and the prior art are presented. Finally, the present design is assessed by comparison of the simulated output resulting from applications of several known neutron sources and dose rates.

  6. Ultraviolet Type B-Radiation-Induced Hyperplasia and Seborrheic Keratosis is Reduced by Application of Commercial Sunscreens

    Directory of Open Access Journals (Sweden)

    Azad K Saeed1*, Snur MA Hassan1 and Nali A Maaruf2

    2016-11-01

    Full Text Available Fifty-six mice were classified into four groups; Group A (control group, n=8, Group B (exposure group, n=16, Group C (n=16 treated with sunscreen 15 minutes before UVB irradiations and group D (n=16 sunscreen treated 60 minutes before UVB exposure. Mice were irradiated 30 minutes 5days/week (12 weeks, and group C-D treated five days/week (12 weeks. Skin samples were taken in the mid and end of the experiment. The result of this study revealed that, epidermal thickness in group A was 7.155µm. At the mid-period of the experiment, severe epidermal hyperplasia was observed in group B with epidermal thickness 118.712µm, while in group C and D mild to moderate epidermal hyperplasia were noted with decreasing epidermal thickness to 64.154 and 90.042µm respectively. At the end of the experiment in Group B epidermal thickness reached to 281.35µm with seborrheic keratosis development, whereas in group C and D totally inhibited the development of seborrheic keratosis and epidermal thickness decreased again into 42.347 and 55.915µm. In conclusion, chronic UVB radiation-led to epidermal hyperplasia and seborrheic keratosis, sunscreen prevented the development of seborrheic keratosis and decreased the UVB-induced epidermal hyperplasia.

  7. Radiation-induced deep levels in n-type GaAs grown by metal-organic chemical-vapor deposition

    Energy Technology Data Exchange (ETDEWEB)

    Naz, Nazir A. [Semiconductor Physics Laboratory, Department of Physics, Quaid-i-Azam University, Islamabad 45320 (Pakistan); Department of Applied Physics, Federal Urdu University of Arts, Science and Technology, G-7/1, Islamabad 45320 (Pakistan); Qurashi, Umar S. [Semiconductor Physics Laboratory, Department of Physics, Quaid-i-Azam University, Islamabad 45320 (Pakistan); Zafar Iqbal, M., E-mail: mziqbal@qau.edu.p [Semiconductor Physics Laboratory, Department of Physics, Quaid-i-Azam University, Islamabad 45320 (Pakistan)

    2009-12-15

    We report a comprehensive study of deep levels in the entire band gap of alpha-irradiated n-type GaAs, grown by metal-organic vapor phase epitaxy (MOVPE), over a wide temperature scan range of 12-475 K. Deep level transient spectroscopy (DLTS) reveals the presence of, at least, seven radiation-induced deep level defects at energy positions E{sub c}-0.05 eV, E{sub c}-0.14 eV, E{sub c}-0.19 eV, E{sub c}-0.34 eV, E{sub c}-0.38 eV, E{sub c}-0.59 eV and E{sub c}-0.69 eV in the upper-half of the band gap, while two radiation-induced defects at energy positions E{sub v}+0.54 eV and E{sub v}+0.77 eV were observed in the lower-half band gap. Some significant differences have been observed with respect to the published work on Schottky barrier diodes. Detailed data on the emission rates, capture cross-sections and introduction rates of the radiation-induced defects are presented. The majority carrier emitting levels at E{sub c}-0.05 eV and E{sub c}-0.14 eV have been found to have electric-field-dependent emission rate signatures.

  8. Characteristics of large Forbush-type decreases in the cosmic radiation. II - Observations at different heliocentric radial distances

    Science.gov (United States)

    Webber, W. R.; Lockwood, J. A.; Jokipii, J. R.

    1986-01-01

    Cosmic ray data from IMP 8, Voyager 1 and 2, Pioneer 10 are used to investigate the heliocentric radial dependence of the characteristics of about 20 Forbush-type transient decreases which occurred from 1978 to 1984. These characteristics include the recovery time, the amplitude, and the time to decrease to minimum. It is found that the average recovery time is about 5 times longer at R = 30 AU than at 1 AU. The magnitudes of the transient decreases are observed to decrease about 1.5 percent/AU on average so that the magnitude of the decrease is half as great at R about 30 AU as at 1 AU. The time for the cosmic ray intensity to decrease to the minimum in the transient decrease is found to be greater at larger distances and is about 5 times longer at R = 30 AU than at 1 AU. The behavior of these effects as a function of radius is obviously related to the evolution of the disturbances causing the transient decreases as they propagate outward. A model of the Forbush-type decrease is proposed to explain the observed radial dependence of the recovery time and time to minimum of the decrease. The implications of these results for understanding the relationship between Forbush-type decreases and the 11-year variation are discussed.

  9. Differentiation between exposures to high or low ionizing radiation by means of Triage type analysis; Diferenciacion entre exposicion a radiacion ionizante alta o baja mediante analisis tipo Triage

    Energy Technology Data Exchange (ETDEWEB)

    Guerrero C, C.; Arceo M, C.; Martinez A, J.; Cortina R, E., E-mail: citlali.guerrero@inin.gob.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2016-09-15

    According to a culture of disaster prevention, in this case a radiological emergency, in which a large number of people are exposed to high doses of ionizing radiation, is necessary to make urgent decisions regarding the appropriate treatment, which for each case is required. In this regard, chromosomal analysis may provide additional information to that obtained from clinical observations confirming cases that suffered severe partial exposure and at the same time discriminating against false positives attributable to previous infections or hysterical behavior. The ionizing radiation causes different types of aberrations in the chromosomes, but one of the most characteristic is dicentric. The analysis of these in lymphocytes is a good indicator of the degree of exposure, because apart from being easily recognizable, the basal frequency in the population is low (1 x 10{sup 3} cells) and increases in proportion to the dose. In order to establish the exposure dose, is usually necessary to analyze 1000 cells, a procedure that in an emergency, is very slow since is necessary to make rapid decisions to apply the appropriate treatment to the patient. The results of this intercalibration exercise demonstrate that the analysis of 20, 30 or 50 metaphases is sufficient to separate the cases of overexposure from the non-radio exposed ones and to the first ones by gravity category. (Author)

  10. On Calibration of pH Meters

    Directory of Open Access Journals (Sweden)

    Da-Ming Zhu

    2005-04-01

    Full Text Available The calibration of pH meters including the pH glass electrode, ISE electrodes,buffers, and the general background for calibration are reviewed. Understanding of basicconcepts of pH, pOH, and electrode mechanism is emphasized. New concepts of pH, pOH,as well as critical examination of activity, and activity coefficients are given. Theemergence of new solid state pH electrodes and replacement of the salt bridge with aconducting wire have opened up a new horizon for pH measurements. A pH buffer solutionwith a conducting wire may be used as a stable reference electrode. The misleadingunlimited linear Nernstian slope should be discarded. Calibration curves with 3 nonlinearportions for the entire 0—14 pH range due to the isoelectric point change effect areexplained. The potential measurement with stirring or unstirring and effects by double layer(DL and triple layer (TL will be discussed.

  11. Recent patents in pressurised metered dose inhalers.

    Science.gov (United States)

    Ehtezazi, Touraj

    2012-04-01

    In this paper recent patents in pressurised metered dose inhalers have been reviewed. The patents are related to novel valves, dose-counters, formulations, add-on devices, reduction of propellant leakage and inkjet technology. Recently patented dose-counters provide mechanisms that are less susceptible to inaccuracy, and are battery-less electronic dose-counters with the help of miniature electromechanical generators. Regarding the formulation aspect, recent patents provide methods for combinational pMDIs and more stable products. Advantages of recently patented valves are being spring-free and less subject to loss of prime. Recent developments in micromachining have allowed patents that incorporate inkjet technology to develop inhalers that are similar to pMDIs, but produce uniform aerosol droplets. Coating canisters with suitable polymers has reduced need for excipients. Recently patented add-on devices reduce aerosol deposition in the spacer by creating turbulence on the walls of the chamber. Blockage of nozzles in actuators is prevented by providing tapered nozzle channels. In conclusion, these patents show better understanding of pMDIs and provide methods to achieve products with much improved reliability, aerosol performance and stability.

  12. Meter data everywhere: online energy information services

    Energy Technology Data Exchange (ETDEWEB)

    Fesmire, R.

    2002-07-01

    The value and importance of web-based energy information services are discussed, emphasizing the advantages of such services to end users and considering ways to encourage end users to make effective use of these advanced metering systems. Results of a survey to investigate key factors in customer acceptance of energy information services show that most energy customers rank guaranteed savings, ease of use and user friendliness as the most important considerations in choosing an energy information service vendor. Among the components end users gave highest rating to the ability provided by energy information services to understand their energy usage, and it is widely agreed that whatever other services EIS may provide, usage analysis is the one that end users are willing to pay a reasonable fee to receive. The pros and cons of in-house-built EIS versus outsourcing was also considered, with the advantage going to outsourcing on account of the shorter implementation time, access to the latest technology, the prospects of freeing up internal resources, and guaranteed system uptime, performance, security and reliability. 3 figs.

  13. Measuring methods in power metering 2013; Elektrizitaetsmesstechnik 2013

    Energy Technology Data Exchange (ETDEWEB)

    Kahmann, Martin; Zayer, Peter (eds.)

    2012-07-01

    The book addresses technical and economic issues of power metering, data communication and data processing. Smart metering is the key issue discussed in all 14 contributions: 1. The perspective of Smart Metering in Europe through 2020; 2. Introduction of Smart Metering in Austria; 3. Metering after the amended EnWG 2011; 4. The FNN project ''MessSystem 2020''; 5. Technological requirements of Smart Grid and Smart Market; 6. DIN Spec 33440 ''Ergonomic Aspects of Smart Grids and Electromobility''; 7. Load management as a key element of energy transition; 8. Added value in Smart Metering as a result of Smart Home applications, 9. The main cost factors of the new metering systems; 10. BSI protection profile: Smart Meter Gateway certification; 11. The influence of new boundary conditions in metering on intercompany processes; 12. Reliable time allotment via internet; 13. Recommendations of the EEG Clearing Authority on metering problems; 14. Outline quality management manual for state-authorized test services for electric power, gas, water, and heat. [German] Dieses Buch richtet seinen Blick sowohl auf technische wie auch auf energiewirtschaftliche Themen rund um das Thema Mess- und Zaehltechnik sowie die inzwischen immer bedeutsamer werdende zugehoerige Datenkommunikations- und Datenverarbeitungstechnik. Eine zunehmende Betrachtung des Smart Metering als einen Teilaspekt des grossen Themas Smart Grid bildet die gemeinsame Klammer um die Beitraege. Die Themen der 14 Beitraege sind: 1. Perspektive Smart Metering in Europa bis 2020; 2. Smart-Meter-Einfuehrung in Oesterreich; 3. Das Messwesen nach der EnWG-Novelle 2011; 4. Das FNN-Projekt ''MessSystem 2020''; 5. Anforderungen durch Smart Grid und Smart Market an die intelligente Messtechnik; 6. DIN Spec 33440 ''Ergonomie-Aspekte zu Smart Grid und Elektromobilitaet''; 7. Lastverschiebung als Baustein der Energiewende; 8. Mehrwerte beim Smart

  14. A link between vascular damage and cognitive deficits after whole-brain radiation therapy for cancer: A clue to other types of dementia?

    Science.gov (United States)

    Yamada, Maki K

    Whole brain radiation therapy for the treatment of tumors can sometimes cause cognitive impairment. Memory deficits were noted in up to 50% of treated patients over a short period of several months. In addition, an increased rate of dementia in young patients has been noted over the longer term, i.e. years. A deficit in neurogenesis after irradiation has been postulated to be the main cause of cognitive decline in patients, but recent data on irradiation therapy for limited parts of the brain appear to indicate other possibilities. Irradiation can directly damage various types of cells other than neuronal stem cells. However, this paper will focus on injury to brain vasculature leading to cognitive decline since vessels represent a better therapeutic target for drug development than other cells in the brain because of the blood-brain barrier.

  15. Comparative sequence analysis and radiation hybrid mapping of two epidermal type II keratin genes in the dog: keratin 1 and keratin 2e.

    Science.gov (United States)

    Credille, K M; Guyon, R; André, C; Murphy, K; Tucker, K; Barnhart, K F; Dunstan, R W

    2005-01-01

    In order to extend knowledge of the process of cornification across species and to be better able to recognize inborn errors in keratin synthesis in the dog, we describe the organization and chromosome mapping of canine KRT1 and KRT2E and compare these results to human and murine sequence data. The coding regions of KRT1 and KRT2E are 1,860 bp and 1,902 bp respectively, distributed over nine exons. Both genes are localized on the canine radiation hybrid map to chromosome 27 in the type II keratin gene cluster close to polymorphic markers. These genes are highly conserved across species and based on both genomic and amino acid sequences, canine KRT1 and KRT2E share greater homology with humans than with mice. Copyright 2005 S. Karger AG, Basel.

  16. Rancang Bangun Dan Pengujian Alat Penjatah (Metering Device Tipe Edge Cell Untuk Penyaluran Pupuk Butiran Urea, TSP dan KCl

    Directory of Open Access Journals (Sweden)

    Syafriandi Syafriandi

    2015-04-01

    Abstract. This study aims to design a fertilizer granules allotment (metering device type of cell edge that can control the fertilizer output by regulating the rotational speed of the motor is assembled with electronic circuits and test the prototypes performance using a metering device with 3 types of fertilizers ie Urea, TSP and KCl. Research tools are designed only able to drain urea and TSP , while KCL fertilizer have trouble escaping from the gap hopper . The average amount of urea metering device 1 output to the voltage 12.16 and 20 volts, respectively for 81.33 g /min, 130.33 g/min and 169.00 g/min. In metering device 2 each fertilizer output voltage feed all values in a row at 75,67 g/min, 129.00 g/min and 168.20 g/min. The average number of TSP output to metering device 1 at the 12.16 and 20 volts, respectively for 121.20 g/min, 181.53 g/min and 244.67 g/min. In metering device 2 each fertilizer output voltage feed all values in a row of 119.27 g/min, 180.53 g/min and 243.73 g/min.

  17. Reduction of the pool-top radiation level in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Choong-Sung; Park, Sang-Jun; Kim, Heonil; Park, Yong-Chul; Choi, Young-San [HANARO Center, Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-08-01

    HANARO is an open-tank-in-pool type reactor. Pool water is the only shielding to minimize the pool top radiation level. During the power ascension test of HANARO, the measured pool top radiation level was higher than the design value because some of the activation products in the coolant reached the pool surface. In order to suppress this rising coolant, the hot water layer system (HWL) was designed and installed to maintain l.2 meter-deep hot water layer whose temperature is 5degC higher than that of the underneath pool surface. After the installation of the HWL system, however, the radiation level of the pool-top did not satisfy the design value. The operation modes of the hot water layer system and the other systems in the reactor pool, which had an effect on the formation of the hot water layer, were changed to reduce pool-top radiation level. After the above efforts, the temperature and the radioactivity distribution in the pool was measured to confirm whether this system blocked the rising coolant. The radiation level at the pool-top was significantly reduced below one tenth of that before installing the HWL and satisfied the design value. It was also confirmed by calculation that this hot water layer system would significantly reduce the release of fission gases to the reactor hall and the environment during the hypothetical accident as well. (author)

  18. Multiple low-dose radiation prevents type 2 diabetes-induced renal damage through attenuation of dyslipidemia and insulin resistance and subsequent renal inflammation and oxidative stress.

    Directory of Open Access Journals (Sweden)

    Minglong Shao

    Full Text Available Dyslipidemia and lipotoxicity-induced insulin resistance, inflammation and oxidative stress are the key pathogeneses of renal damage in type 2 diabetes. Increasing evidence shows that whole-body low dose radiation (LDR plays a critical role in attenuating insulin resistance, inflammation and oxidative stress.The aims of the present study were to investigate whether LDR can prevent type 2 diabetes-induced renal damage and the underlying mechanisms.Mice were fed with a high-fat diet (HFD, 40% of calories from fat for 12 weeks to induce obesity followed by a single intraperitoneal injection of streptozotocin (STZ, 50 mg/kg to develop a type 2 diabetic mouse model. The mice were exposed to LDR at different doses (25, 50 and 75 mGy for 4 or 8 weeks along with HFD treatment. At each time-point, the kidney weight, renal function, blood glucose level and insulin resistance were examined. The pathological changes, renal lipid profiles, inflammation, oxidative stress and fibrosis were also measured.HFD/STZ-induced type 2 diabetic mice exhibited severe pathological changes in the kidney and renal dysfunction. Exposure of the mice to LDR for 4 weeks, especially at 50 and 75 mGy, significantly improved lipid profiles, insulin sensitivity and protein kinase B activation, meanwhile, attenuated inflammation and oxidative stress in the diabetic kidney. The LDR-induced anti-oxidative effect was associated with up-regulation of renal nuclear factor E2-related factor-2 (Nrf-2 expression and function. However, the above beneficial effects were weakened once LDR treatment was extended to 8 weeks.These results suggest that LDR exposure significantly prevented type 2 diabetes-induced kidney injury characterized by renal dysfunction and pathological changes. The protective mechanisms of LDR are complicated but may be mainly attributed to the attenuation of dyslipidemia and the subsequent lipotoxicity-induced insulin resistance, inflammation and oxidative stress.

  19. Development of a novel vortex flow meter for downhole use

    NARCIS (Netherlands)

    Schiferli, W.; Cheng, L.K.

    2008-01-01

    Due to the increasing complexity of oil and gas wells, the demand for instrumentation to measure conditions inside well tubing below the surface is growing rapidly. A robust meter was designed to measure liquid flows at downhole conditions. The meter is based on a specially-designed bluff body to

  20. Investigating water meter performance in developing countries: A ...

    African Journals Online (AJOL)

    2011-10-07

    Oct 7, 2011 ... High levels of water losses in distribution systems are the main challenge that water utilities in developing countries cur- rently face. ... industry, especially in developing countries, to make appropriate metering and sub-metering decisions. ... the case study, followed by the research methodology used in.

  1. Real time Aanderaa current meter data collection system

    Digital Repository Service at National Institute of Oceanography (India)

    AshokKumar, K.; Diwan, S.G.

    in laboratory. In this paper a method is described to read the real time current meter data and display/print/store on cartridge. For this, binary coded electrical signal available at the top end plate of the current meter is connectEd. by underwater cable...

  2. Inaccuracy of portable peak flow meters : correction is not needed

    NARCIS (Netherlands)

    Brand, PLP; Waalkens, HJ; Duiverman, EJ; vanEssenZandvliet, EEM

    This study examined whether correction of peak expiratory flow (PEF) values for the inaccuracy of the meter would affect asthma management in 102 children (7-14 y old). PEF was recorded with a mini Wright meter twice daily for 2 weeks. As expected, measured PEF overestimated PEF level and asthma

  3. The accuracy of self monitoring blood glucose meter systems in ...

    African Journals Online (AJOL)

    However, those on meter system B and C were significantly lower and different. Temperature and humidity adversely affected the analytical performance of meter systems B and C in the Kampala environ. Conclusion: Some of the blood glucose monitoring systems in Kampala, Uganda are poor performers and may lead to ...

  4. Investigating water meter performance in developing countries: A ...

    African Journals Online (AJOL)

    High levels of water losses in distribution systems are the main challenge that water utilities in developing countries currently face. The water meter is an essential tool for both the utility and the customers to measure and monitor consumption. When metering is inefficient and coupled with low tariffs, the financial ...

  5. 24 CFR 965.401 - Individually metered utilities.

    Science.gov (United States)

    2010-04-01

    ... Existing PHA-Owned Projects § 965.401 Individually metered utilities. (a) All utility service shall be individually metered to residents, either through provision of retail service to the residents by the utility... or public service commission. (b) If checkmetering is not permissible, retail service shall be...

  6. Microwave moisture meter for in-shell peanut kernels

    Science.gov (United States)

    . A microwave moisture meter built with off-the-shelf components was developed, calibrated and tested in the laboratory and in the field for nondestructive and instantaneous in-shell peanut kernel moisture content determination from dielectric measurements on unshelled peanut pod samples. The meter ...

  7. Designing remote web-based mechanical-volumetric flow meter ...

    African Journals Online (AJOL)

    Today, in water and wastewater industry a lot of mechanical-volumetric flow meters are used for the navigation of the produced water and the data of these flow meters, due to use in a wide geographical range, is done physically and by in person presence. All this makes reading the data costly and, in some cases, due to ...

  8. 18 CFR 367.9020 - Account 902, Meter reading expenses.

    Science.gov (United States)

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Account 902, Meter reading expenses. 367.9020 Section 367.9020 Conservation of Power and Water Resources FEDERAL ENERGY... GAS ACT Operation and Maintenance Expense Chart of Accounts § 367.9020 Account 902, Meter reading...

  9. Justification of the Utility of Introducing Smart Meters in Latvia

    Directory of Open Access Journals (Sweden)

    Kunickis M.

    2015-12-01

    Full Text Available Automatic data reading from smart meters is being developed in many parts of the world, including Latvia. The key drivers for that are developments of smart technologies and economic benefits for consumers. Deployment of smart meters could be launched in a massive scale.

  10. Development and Testing of Infrared Water Current Meter | Ezenne ...

    African Journals Online (AJOL)

    Continuous monitoring of the river flow is essential for assessing water availability. River flow velocity is crucial to simulate discharge hydrographs of water in the hydrological system.This study developed a digital water current meter with infrared. The infrared current meter was tested using Ebonyi River at Obollo-Etiti and ...

  11. A prepaid meter using mobile communication | Jain | International ...

    African Journals Online (AJOL)

    This paper suggests a prepaid energy meter behaving like a prepaid mobile phone. The meter contains a prepaid card analogous to mobile SIM card. The prepaid card communicates with the power utility using mobile communication infrastructure. Once the prepaid card is out of balance, the consumer load is disconnected ...

  12. Design of a Robust Prepaid Energy Metering and Billing System ...

    African Journals Online (AJOL)

    ... detector(GBTD) which detects abnormalities and sends sms alert to power utility for on site visit or investigation. A prior billing is bound to do away with the problems of unpaid bills and human error in meter readings, thereby ensuring justified revenue for the utility. Keywords: SMS, GSM, microcontroller, energy meter, ...

  13. The Thirty Meter Telescope (TMT): An International Observatory

    Indian Academy of Sciences (India)

    2016-01-27

    Jan 27, 2016 ... The Thirty Meter Telescope (TMT) will be the first truly global ground-based optical/infrared observatory. It will initiate the era of extremely large (30-meter class) telescopes with diffraction limited performance from its vantage point in the northern hemisphere on Mauna Kea, Hawaii, USA. The astronomy ...

  14. Conjunct action of gamma radiation and casiopeinas in two cellular types; Accion conjunta de radiacion gamma y casiopeinas en dos tipos celulares

    Energy Technology Data Exchange (ETDEWEB)

    Ramos V, N.I

    2006-07-01

    In Mexico the cancer occupies the second place in the causes of death and although already there are diverse useful treatments to attack this suffering, the search of new pharmaceuticals that present positive effect in the treatment of the cancer there is taken to the development of a group of substances called Casiopeinas. Its are coordination compounds constituted by a central atom of copper (Cu II) joined to organic ligands, with general condensed formula [Cu (NN)(ON)]NO{sub 3}, or [Cu(NN)(OO)]NO{sub 3}. Its present different cytotoxicity levels, as well as in vitro antineoplastic activity in diverse tissues derived of tumors. Even its ignore the mechanisms of it action, but one of them, it could be by generation of reactive species of oxygen (ERO), mediated by the metallic center that contain. Thinking of this possibility was carried out in vitro experiments, exposing lymphocytes or HeLa cells, to ionizing radiation, at two casiopeinas (Casiopeina llgly and the Casiopeina Ill-e-a) or the combination of both agents, in order to determine if the antineoplastic capacity of both types of treatments increase in conjunct action. To determine it its were carried out cytotoxicity tests by means of the differential dyeing of fluorescein diacetate and etidio bromide, in these the cells alive fluorescein in green color while the dead ones only the nucleus of red tinged. The genotoxicity was evaluated by means of the comet essay. The results hurtled that as much the casiopeinas as the radiation by separate don't present difference among both cellular types, probably due to the used method that only quantifies the damages at the moment and not to long term. And according to those treatments on the whole only to the concentrations and the doses more high it favors the additive effect due to an overproduction of free radicals that not can be neutralized. According to the genotoxicity, only proven for the radiation indicates that the HeLa cells presents a major number of

  15. Optical, microphysical and radiative properties of aerosols over a tropical rural site in Kenya, East Africa: Source identification, modification and aerosol type discrimination

    Science.gov (United States)

    Boiyo, Richard; Kumar, K. Raghavendra; Zhao, Tianliang

    2018-03-01

    A better understanding of aerosol optical, microphysical and radiative properties is a crucial challenge for climate change studies. In the present study, column-integrated aerosol optical and radiative properties observed at a rural site, Mbita (0.42°S, 34.20 °E, and 1125 m above sea level) located in Kenya, East Africa (EA) are investigated using ground-based Aerosol Robotic Network (AERONET) data retrieved during January, 2007 to December, 2015. The annual mean aerosol optical depth (AOD500 nm), Ångström exponent (AE440-870 nm), fine mode fraction of AOD500 nm (FMF500 nm), and columnar water vapor (CWV, cm) were found to be 0.23 ± 0.08, 1.01 ± 0.16, 0.60 ± 0.07, and 2.72 ± 0.20, respectively. The aerosol optical properties exhibited a unimodal distribution with substantial seasonal heterogeneity in their peak values being low (high) during the local wet (dry) seasons. The observed data showed that Mbita and its environs are significantly influenced by various types of aerosols, with biomass burning and/or urban-industrial (BUI), mixed (MXD), and desert dust (DDT) aerosol types contributing to 37.72%, 32.81%, and 1.40%, respectively during the local dry season (JJA). The aerosol volume size distribution (VSD) exhibited bimodal lognormal structure with a geometric mean radius of 0.15 μm and 3.86-5.06 μm for fine- and coarse-mode aerosols, respectively. Further, analysis of single scattering albedo (SSA), asymmetry parameter (ASY) and refractive index (RI) revealed dominance of fine-mode absorbing aerosols during JJA. The averaged aerosol direct radiative forcing (ARF) retrieved from the AERONET showed a strong cooling effect at the bottom of the atmosphere (BOA) and significant warming within the atmosphere (ATM), representing the important role of aerosols played in this rural site of Kenya. Finally, the Hybrid Single Particle Lagrangian Integrated Trajectory (HYSPLIT) model revealed that aerosols from distinct sources resulted in enhanced loading

  16. Search for optical emission from radio pulsars at the 6-meter telescope

    Energy Technology Data Exchange (ETDEWEB)

    Lebedev, V.S.; Neizvestnyj, S.I.; Pimonov, A.A.; Plakhotnichenko, V.L.

    From the results of the investigation of eight radio pulsars made at the 6-meter telescope of the Special astrophysical observatory of the Academy of Sciences of USSR, the restrictions on their optical luminosities in the wavelength region lambda=3500-6000 A have been obtained. Corresponding limits on the stellar magnitudes msub(B), of these pulsars (under the assumption that the spectra of optical radiation of these pulsars are similar to that of the Crab Nebula pulsar) are approximately 25-26sup(m).

  17. Determination of the occurrence of gold in an unoxidized Carlin-type ore sample using synchrotron radiation

    Science.gov (United States)

    Chen, J.R.; Chao, E.C.T.; Minkin, J.A.; Back, J.M.; Bagby, W.C.; Rivers, M.L.; Sutton, S.R.; Gordon, B.M.; Hanson, A.L.; Jones, K.W.

    1987-01-01

    The occurrence of the so-called invisible gold in two unoxidized Carlin-type gold samples from Nevada has been determined using synchrotron X-ray fluorescence (SXRF) analysis at the National Synchrotron Light Source, Brookhaven National Laboratory. A bedded sample from the East ore zone of the Carlin deposit and a breccia sample from Horse Canyon were analyzed. Preliminary results show that gold is found only in the Horse Canyon breccia sample. Experimental details including other X-ray line and diffraction peak interferences, standards used, and minimum detection limits (MDLs) are discussed. Gold, with a MDL range of 0.8 to 3 ppm, was not detected in euhedral pyrite crystals except in the interior porous portion of one grain. Gold was detected in some parts of the matrix. The phase which contains gold has not yet been identified. The highest content of gold so far analyzed is about 40 ppm. There are interesting implications of these new findings. ?? 1987.

  18. An Improved Platform Levelling System for Airborne Gravity Meters.

    Science.gov (United States)

    Brady, N.

    2014-12-01

    Recent advances in sensor technology have enabled Lacoste and Romberg type relative gravity meters to improve in accuracy to the point where other non-sensor related sources of error serve to limit the overall accuracy of the system. One of these sources of error is derived from the inability of the platform, in which the sensor is mounted, to keep the sensor perfectly level during survey flight. Off level errors occur when the aircraft is unable to maintain straight and level flight along a survey line. The levelling platform of a typical Lacoste and Romberg type dynamic gravity meter utilizes a complex feedback loop involving both accelerometers and gyroscopes with an output connected to torque motors mounted to the platform to sense an off level situation and correct for it. The current system is limited by an inability of the platform to distinguish between an acceleration of the platform due to a change in heading, altitude or speed of the aircraft and a true change in the local gravity vertical. Both of these situations cause the platform to tilt in reponse however the aircraft acceleration creates an error in the gravity measurement. These off level errors can be corrected for to a limited degree depending on the algorithm used and the size and duration of the causal acceleration. High precision GPS now provides accurate real time position information which can be used to determine if an accleration is a real level change or due to an anomalous acceleration. The correct implementation of the GPS position can significantly improve the accuracy of the platform levelling including keeping the platform level during course reversals or drape flying during a survey. This can typically improve the quality of the gravity data before any processing corrections. The enhanced platform also reduces the time taken to stabilize the platform at the beginning of a survey line therefore improving the efficiency of the data collection. This paper discusses the method and

  19. Radiation Therapy

    Science.gov (United States)

    ... Be extra careful not to spend time with children or pregnant women. Internal Radiation Therapy Makes You Give Off Radiation With systemic radiation, your body fluids ( urine , sweat, and saliva ) will give off radiation for a while. With ...

  20. Radiation enteritis

    Science.gov (United States)

    Radiation enteropathy; Radiation-induced small bowel injury; Post-radiation enteritis ... Radiation therapy uses high-powered x-rays, particles, or radioactive seeds to kill cancer cells. The therapy ...

  1. Measurement of the irradiation of generating lamps of radiation ultraviolet type A used in tan equipment Sportarredo model Ringo 1200; Medicion de la irradiancia de lamparas generadoras de radiacion ultravioleta tipo A usadas en equipo de bronceado Sportarredo Modelo Ringo 1200

    Energy Technology Data Exchange (ETDEWEB)

    Gama T, G., E-mail: cxxi@prodigy.net.m [Calidad XXI, Zacatecas 67-007, Col. Roma, 06700 Mexico D. F. (Mexico)

    2010-09-15

    In the last years has been developed in the cosmetology market the application of ultraviolet radiation (UV) in known equipment s as cameras or tan beds to obtain a change in the pigmentation of the skin. In Mexico, this fashion has entered without the appropriate recommendations of prevention against the risks of the adverse effects from the disproportionate exhibition to such non ionizing energy form; which is electromagnetic radiation in the interval of 400 nm to 100 nm of wave longitude, classified in near UV-A of 400 nm to 315 nm, and distant: UV-B of 315 nm to 280 nm and UV-C of 280 nm to 100 nm. Therefore, they have not been included in the national normative the necessary regulations regarding the operation parameters of the tan cameras for the E irradiation levels. The level E is defined as the incident radiation power in a receiver surface to a specific localization and relative orientation to the radiant surface expressed in units of the International System, W/m{sup 2} or MW/cm{sup 2}. The objective of this work is to show the measurement results for the E of a camera that contains two emitters arrangements, a first to whole body that consist of 8 lamp pairs model B17L of 160 Watts, which will have a nominal E of 358 W/m{sup 2} (35.8 MW/cm{sup 2}) for UV type A and 3.3 W/m{sup 2} (0.33 MW/cm{sup 2}) for UV type B; one second to face of 8 lamps model KALFASUN 630, with an E of 568 W/m{sup 2} (56.8 MW/cm{sup 2}) for UV type A and 2.97 W/m{sup 2} (0.297 MW/cm{sup 2}) for UV type B. The E measurements are carried out for UV-A with the body and face lamp, respectively; with two instruments: photometer mark Sportarredo, model BF01, series E009, and radiometer mark Ets without specified model. Additional the treatment time is verified with the chronometer of the digital screen of the equipment comparing it with a digital meter with resolution of 0.001 s. Conclusion: the lamps do not fulfill the E nominal values reported by the manufacturer, being minors 3.2 to

  2. Justification of the Utility of Introducing Smart Meters in Latvia

    Science.gov (United States)

    Kunickis, M.; Dandens, A.; Bariss, U.

    2015-12-01

    Automatic data reading from smart meters is being developed in many parts of the world, including Latvia. The key drivers for that are developments of smart technologies and economic benefits for consumers. Deployment of smart meters could be launched in a massive scale. Several pilot projects were implemented to verify the feasibility of smart meters for individual consumer groups. Preliminary calculations indicate that installation of smart meters for approximately 23 % of electricity consumers would be economically viable. Currently, the data for the last two years is available for an in-depth mathematical analysis. The continuous analysis of consumption data would be established, when more measurements from smart meters are available. The extent of introduction of smart meters should be specified during this process in order to gain the maximum benefit for the whole society (consumers, grid companies, state authorities), because there are still many uncertain and variable factors. For example, it is necessary to consider statistical load variations by hour, dependence of electricity consumption on temperature fluctuations, consumer behaviour and demand response to market signals to reduce electricity consumption in the short and long term, consumer's ambitions and capability to install home automation for regulation of electricity consumption. To develop the demand response, it is necessary to analyse the whole array of additional factors, such as expected cost reduction of smart meters, possible extension of their functionality, further development of information exchange systems, as well as standard requirements and different political and regulatory decisions regarding the reduction of electricity consumption and energy efficiency.

  3. Reflected solar radiation from horizontal, vertical and inclined surfaces: ultraviolet and visible spectral and broadband behaviour due to solar zenith angle, orientation and surface type.

    Science.gov (United States)

    Turner, J; Parisi, A V; Turnbull, D J

    2008-07-24

    Ultraviolet (UV) radiation affects human life and UV exposure is a significant everyday factor that individuals must be aware of to ensure minimal damaging biological effects to themselves. UV exposure is affected by many complex factors. Albedo is one factor, involving reflection from flat surfaces. Albedo is defined as the ratio of reflected (upwelling) irradiance to incident (downwelling) irradiance and is generally accepted only for horizontal surfaces. Incident irradiance on a non horizontal surface from a variety of incident angles may cause the reflectivity to change. Assumptions about the reflectivity of a vertical surface are frequently made for a variety of purposes but are rarely quantified. As urban structures are dominated by vertical surfaces, using albedo to estimate influence on UV exposure is limiting when incident (downwelling) irradiance is not normal to the surface. Changes to the incident angle are affected by the solar zenith angle, surface position and orientation and surface type. A new characteristic describing reflection from a surface has been used in this research. The ratio of reflected irradiance (from any surface position of vertical, horizontal or inclined) to global (or downwelling) irradiance (RRG) has been calculated for a variety of metal building surfaces in winter time in the southern hemisphere for both the UV and visible radiation spectrum, with special attention to RRG in the UV spectrum. The results show that the RRG due to a vertical surface can exceed the RRG due to a horizontal surface, at smaller solar zenith angles as well as large solar zenith angles. The RRG shows variability in reflective capacities of surface according to the above mentioned factors and present a more realistic influence on UV exposure than albedo for future investigations. Errors in measuring the RRG at large solar zenith angles are explored, which equally highlights the errors in albedo measurement at large solar zenith angles.

  4. Weather Impact on Airport Arrival Meter Fix Throughput

    Science.gov (United States)

    Wang, Yao

    2017-01-01

    Time-based flow management provides arrival aircraft schedules based on arrival airport conditions, airport capacity, required spacing, and weather conditions. In order to meet a scheduled time at which arrival aircraft can cross an airport arrival meter fix prior to entering the airport terminal airspace, air traffic controllers make regulations on air traffic. Severe weather may create an airport arrival bottleneck if one or more of airport arrival meter fixes are partially or completely blocked by the weather and the arrival demand has not been reduced accordingly. Under these conditions, aircraft are frequently being put in holding patterns until they can be rerouted. A model that predicts the weather impacted meter fix throughput may help air traffic controllers direct arrival flows into the airport more efficiently, minimizing arrival meter fix congestion. This paper presents an analysis of air traffic flows across arrival meter fixes at the Newark Liberty International Airport (EWR). Several scenarios of weather impacted EWR arrival fix flows are described. Furthermore, multiple linear regression and regression tree ensemble learning approaches for translating multiple sector Weather Impacted Traffic Indexes (WITI) to EWR arrival meter fix throughputs are examined. These weather translation models are developed and validated using the EWR arrival flight and weather data for the period of April-September in 2014. This study also compares the performance of the regression tree ensemble with traditional multiple linear regression models for estimating the weather impacted throughputs at each of the EWR arrival meter fixes. For all meter fixes investigated, the results from the regression tree ensemble weather translation models show a stronger correlation between model outputs and observed meter fix throughputs than that produced from multiple linear regression method.

  5. Liquid ultrasonic flow meters for crude oil measurement

    Energy Technology Data Exchange (ETDEWEB)

    Kalivoda, Raymond J.; Lunde, Per

    2005-07-01

    Liquid ultrasonic flow meters (LUFMs) are gaining popularity for the accurate measurement of petroleum products. In North America the first edition of the API standard ''Measurement of liquid hydrocarbons by ultrasonic flow meters using transit time technology'' was issued in February 2005. It addresses both refined petroleum products and crude oil applications. Its field of application is mainly custody transfer applications but it does provide general guidelines for the installation and operation of LUFM's other applications such as allocation, check meters and leak detection. As with all new technologies performance claims are at times exaggerated or misunderstood and application knowledge is limited. Since ultrasonic meters have no moving parts they appear to have fewer limitations than other liquid flow meters. Liquids ultrasonic flow meters, like turbine meters, are sensitive to fluid properties. It is increasingly more difficult to apply on high viscosity products then on lighter hydrocarbon products. Therefore application data or experience on the measurement of refined or light crude oil may not necessarily be transferred to measuring medium to heavy crude oils. Before better and more quantitative knowledge is available on how LUFMs react on different fluids, the arguments advocating reduced need for in-situ proving and increased dependency on laboratory flow calibration (e.g. using water instead of hydrocarbons) may be questionable. The present paper explores the accurate measurement of crude oil with liquid ultrasonic meters. It defines the unique characteristics of the different API grades of crude oils and how they can affect the accuracy of the liquid ultrasonic measurement. Flow testing results using a new LUFM design are discussed. The paper is intended to provide increased insight into the potentials and limitations of crude oil measurement using ultrasonic flow meters. (author) (tk)

  6. Effects of Net Metering on the Use of Small-Scale Wind Systems in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Forsyth, T. L.; Pedden, M.; Gagliano, T.

    2002-11-01

    Factors such as technological advancements, steadily decreasing costs, consumer demand, and state and federal policies are combining to make wind energy the world's fastest growing energy source. State and federal policies are facilitating the growth of the domestic, large-scale wind power market; however, small-scale wind projects (those with a capacity of less than 100 kilowatts[kW]) still face challenges in many states. Net metering, also referred to as net billing, is one particular policy that states are implementing to encourage the use of small renewable energy systems. Net metering allows individual, grid-tied customers who generate electricity using a small renewable energy system to receive credit from their utility for any excess power they generate beyond what they consume. Under most state rules, residential, commercial, and industrial customers are eligible for net metering; however, some states restrict eligibility to particular customer classes. This paper illustrates how net metering programs in certain states vary considerably in terms of how customers are credited for excess power they generate; the type and size of eligible technologies and whether the utility; the state, or some other entity administers the program. This paper focuses on10 particular states where net metering policies are in place. It analyzes how the different versions of these programs affect the use of small-scale wind technologies and whether some versions are more favorable to this technology than others. The choice of citizens in some states to net meter with photovoltaics is also examined.

  7. Diabetic glucose meter for the determination of glucose in microbial cultures.

    Science.gov (United States)

    Flavigny, Raphael

    2014-05-01

    In wastewater, biological phosphate removal can fail because of the presence of glycogen accumulating organism (GAO), therefore measuring glycogen stored in microbial cultures provides information on the bacterial population type. Once glycogen is hydrolysed to glucose it was accurately measured using a human glucose meter. The standard curves demonstrate linearity regardless of the pre-treatment of the glucose solution at neutral pH. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Checking liquid meters. Marketers find ''master meter program'' provides reliable, economical method to check truck meters

    Energy Technology Data Exchange (ETDEWEB)

    Lady, P.

    1976-08-01

    With LP-gas prices continuing to increase, LP-gas marketers are becoming increasingly aware of the need for testing liquid meters on trucks used for delivering bulk propane. Many large marketers are aware of the need for consistent testing and are establishing periodic programs for their truck fleets. Because the official test equipment--the volumetric meter power--is expensive and requires a highly trained operator, many dealers are seeking simpler, less expensive testing methods to make sure that their meters are dispensing fuel. The more accurate of the two alternative methods is a master meter which has been calibrated against a prover and whose variations are known for different flow rates. The method's main disadvantage is the possibility that the master meter might be in error. The last method, which uses truck scales, is the least expensive and most readily available to all operators but also is the least accurate and is time-consuming, especially in low-flow tests.

  9. Hybrid TLC-pair meter for the Sphinx Project

    Science.gov (United States)

    Wada, T.; Yamamoto, I.; Takahashi, N.; Misaki, A.

    1985-01-01

    The chief aims in THE SPHINX PROJECT are research of super lepton physics and new detector experiments. At the second phase of THE SPHINX PROJECT, a hybrid TLC-PAIR METER was designed for measuring high energy neutrino sources (E upsilon * TeV), searching high energy muon sources (E mu TeV) and measuring muon group (E mu 1 TeV). The principle of PAIR METER has been already proposed. In this TLC-PAIR METER, electromagnetic shower induced by cosmic ray muons are detected using TL (Thermoluminescence) sheets with position counters.

  10. Topology-Based Estimation of Missing Smart Meter Readings

    Directory of Open Access Journals (Sweden)

    Daisuke Kodaira

    2018-01-01

    Full Text Available Smart meters often fail to measure or transmit the data they record when measuring energy consumption, known as meter readings, owing to faulty measuring equipment or unreliable communication modules. Existing studies do not address successive and non-periodical missing meter readings. This paper proposes a method whereby missing readings observed at a node are estimated by using circuit theory principles that leverage the voltage and current data from adjacent nodes. A case study is used to demonstrate the ability of the proposed method to successfully estimate the missing readings over an entire day during which outages and unpredictable perturbations occurred.

  11. Federal metering data analysis needs and existing tools

    Energy Technology Data Exchange (ETDEWEB)

    Henderson, Jordan W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Fowler, Kimberly M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-07-01

    Agencies have been working to improve their metering data collection, management, and analysis efforts over the last decade (since EPAct 2005) and will continue to address these challenges as new requirements and data needs come into place. Unfortunately there is no “one-size-fits-all” solution. As agencies continue to expand their capabilities to use metered consumption data to reducing resource use and improve operations, the hope is that shared knowledge will empower others to follow suit. This paper discusses the Federal metering data analysis needs and some existing tools.

  12. Analysis of in-situ spectral absorption meter data

    Science.gov (United States)

    Zaneveld, J. Ronald V.; Kitchen, James C.; Bricaud, Annick; Moore, Casey C.

    1992-12-01

    In situ absorption data collected with a reflective-tube absorption meter are presented. Various procedures for correcting the data for scattering error and for extracting chlorophyll absorption from the raw signal are explored. Based on our knowledge of the distribution of particle types and on measured backscattering, the scattering correction as a function of total scattering is found to vary significantly with depth. However, absorption in the near infrared is shown to be highly correlated with backscattering. We thus postulate that this signal is mainly due to the scattering error and possibly to absorption by dissolved substances and particles of a detrital nature. Thus, the infrared signal seems to provide a good correction for the measured a(676) to obtain chloropigment absorption. Indeed, a(676) - a(750) (corrected for water absorption and 750 temperature dependence) was found to correlate strongly with fluorescence. However, a(750) was found to be highly temperature dependent, so a(712) was chosen for this purpose in future measurements. An examination of optical microstructure in East Sound, Orcas Island, Washington showed numerous peaks with vertical dimensions of the order of tens of centimeters. These peaks may contain the majority of the biomass in the system. The relative magnitude of the a(676) - a(712) and the a(712) signals varied greatly from one peak to another and systematically with depth, presumably reflecting the nature and physiological states of the populations in the various peaks.

  13. Evaluating differential nuclear DNA yield rates and osteocyte numbers among human bone tissue types: A synchrotron radiation micro-CT approach.

    Science.gov (United States)

    Andronowski, Janna M; Mundorff, Amy Z; Pratt, Isaac V; Davoren, Jon M; Cooper, David M L

    2017-05-01

    Molecular human identification has conventionally focused on DNA sampling from dense, weight-bearing cortical bone tissue, typically from femora or tibiae. A comparison of skeletal elements from three contemporary individuals demonstrated that elements with high quantities of cancellous bone yielded nuclear DNA at the highest rates, suggesting that preferentially sampling cortical bone may be suboptimal (Mundorff & Davoren, 2014). Despite these findings, the reason for the differential DNA yields between cortical and cancellous bone tissues remains unknown. The primary goal of this work is to ascertain whether differences in bone microstructure can be used to explain differential nuclear DNA yield among bone tissue types observed by Mundorff and Davoren (2014), with a focus on osteocytes and the three-dimensional (3D) quantification of their associated lacunae. Osteocytes and other bone cells are recognized to house DNA in bone tissue, thus examining the density of their lacunae may explain why nuclear DNA yield rates differ among bone tissue types. Lacunae were visualized and quantified using synchrotron radiation-based micro-Computed Tomographic imaging (SR micro-CT). Volumes of interest (VOIs) from cortical and cancellous bone tissues (n=129) were comparatively analyzed from the three skeletons sampled for Mundorff and Davoren's (2014) study. Analyses tested the primary hypothesis that the abundance and density of osteocytes (inferred from their lacunar spaces) vary between cortical and cancellous bone tissue types. Results demonstrated that osteocyte lacunar abundance and density vary between cortical and cancellous bone tissue types, with cortical bone VOIs containing a higher lacunar abundance and density. We found that the osteocyte lacunar density values are independent of nuclear DNA yield, suggesting an alternative explanation for the higher nuclear DNA yields from bones with greater quantities of cancellous bone tissue. The use of SR micro-CT allowed for

  14. Radiation Therapy: Additional Treatment Options

    Science.gov (United States)

    ... Cancer Upper GI Cancers Search x FIND A RADIATION ONCOLOGIST CLOSE SNIPEND TREATMENT TYPES SNIPSTART Home / Treatment ... novel targeted therapies can act as radiosensitizers. Systemic Radiation Therapy Certain cancers may be treated with radioactive ...

  15. Radiation recall dermatitis with azithromycin

    OpenAIRE

    Vujovic, O.

    2010-01-01

    Radiation recall is a well-known phenomenon that involves the “recall” of an acute inflammatory reaction in a previously irradiated region after administration of certain drugs. The most common type of radiation recall is radiation recall dermatitis, which involves the reoccurrence of an acute inflammatory skin reaction in previously irradiated skin. Most radiation recall reactions are attributable to chemotherapeutic agents. One previously reported case of radiation recall dermatitis occurre...

  16. Open for new ideas. Metering management in the energy service sector; Offen fuer neue Ideen. Metering Management beim Energiedienst

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2010-10-04

    Smarter grids - this is one of the goals of the Rheinfelden energy service. At an early stage already, the energy service began to introduce new business processes like smart metering and related technologies, with an orientation along the requirements of the market and the pertinent legal regulations. A flexible software was used in metering management in order to best achieve the targeted goals. The energy service is now testing the applicability of DSL and GPRS in three smart meter field tests, each in a separate new housing area with different boundary conditions. (orig.)

  17. One-Meter Class Drilling for Planetary Exploration Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The purpose of the proposed effort is to understand and characterize the fundamental limitations of drilling one to three meters into challenging materials which may...

  18. Quantifying uncertainty contributions for fibre optic power meter calibrations

    CSIR Research Space (South Africa)

    Nel, M

    2009-09-01

    Full Text Available A fibre optic power meter calibration has several uncertainty contributors associated with it. In order to assign a realistic uncertainty to the calibration result it is necessary to realistically estimate the magnitude of each uncertainty...

  19. Electric Power Substitute Meter Management via Mobile Application

    Directory of Open Access Journals (Sweden)

    Nelson C. Rodelas

    2014-10-01

    Full Text Available EPSMvMA is composed of Digital Sub-Meter connected to different components namely the GSM module, Bluetooth module, Power Analyzer Module, LCD Module, Relay Module and Main Microcontroller module. The connection via Mobile is made possible by the modules mentioned. The software that the proponents will be dealing with in the study is C++ language, which will be used in programming the Main Microcontroller module and Visual Basic Language for the Android Phones. The Bluetooth module can access the Android Phones and connect to the digital sub-meter in a limited distance. The users will be at ease since a code embedded to the microcontroller will make the utility sub-meter produce the desired value of electricity (KWH and wherein the computed Sub-meter reading can be viewed through the LCD. This project is accommodating to those person that is always on the go and prudent.

  20. 100-Meter Resolution Satellite View of Hawaii - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The Satellite View of Hawaii map layer is a 100-meter resolution simulated natural-color image of Hawaii. Vegetation is generally green, with forests in darker green...

  1. Tweeting : Smart meters raise awareness of energy consumption in buildings

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2009-11-15

    The University of Mississippi (UM) will monitor, analyze and report on energy consumption in its campus buildings in real-time using SmartSynch Smart Meters. The technology uses smart meter data to help identify a detailed pattern of electricity usage with the objective of finding methods to alter behaviour to reduce electricity usage and carbon emissions. SmartSynch installed 16 Smart Meters on campus with additional deployments being planned. The technology will enable the university to monitor energy consumption, track building power performance over time, compare building energy usage, and review the impact of the weather on energy use while reducing its carbon footprint. Additionally, UM will use Facebook, Twitter and an RSS feed to provide regular public updates on its buildings' energy consumption based on SmartSynch Smart Meter data. Each building will have its own profile on the social networking sites. 1 ref., 1 fig.

  2. 100-Meter Resolution Grayscale Shaded Relief of Hawaii - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The Grayscale Shaded Relief of Hawaii map layer is a 100-meter resolution grayscale shaded relief image of Hawaii, in an Albers Equal-Area Conic projection. Shaded...

  3. 100-Meter Resolution Grayscale Shaded Relief of Alaska - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The Grayscale Shaded Relief of Alaska map layer is a 100-meter resolution grayscale shaded relief image of Alaska, in an Albers Equal-Area Conic projection. Shaded...

  4. Lightweight Thermally Stable Multi-Meter Aperture Submillimeter Reflectors Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of the Phase II effort will be an affordable demonstrated full-scale design for a thermally stable multi-meter submillimeter reflector. The Phase I...

  5. Grayscale Hawaii Shaded Relief ? 200-Meter Resolution - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The grayscale Hawaii shaded relief data were derived from National Elevation Dataset (NED) data, and show the terrain of Hawaii at a resolution of 200 meters. The...

  6. ASTER Global Emissivity Dataset, 100 meter, Binary V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The AG100B.003 dataset was decommissioned as of December 14, 2016. Users are encouraged to use the ASTER Global Emissivity Dataset 100-meter (AG100.003 -...

  7. Guanabara Bay and Pecem LNG flexible metering systems

    Energy Technology Data Exchange (ETDEWEB)

    Torres, Vinicus Roberto C.; Carvalho, Gustavo L.A.; Bruel, Edson L.; Santana, Jose P.C. de; Vidal, Lud C.C.N. [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil)

    2009-12-19

    This work presents to the community the metering systems installed in the Liquefied Natural (LNG) Gas Flexible Terminals of the Pecem Port and Guanabara Bay. A brief description of the Terminals facilities and its operation is firstly made to provide a background of the systems discussed. Then, the LNG custody transfer metering system, the operational control metering system, the energy balance of the LNG transferring system and the Natural Gas custody transfer metering system - that are our systems of interest - are described in detail. It is intended to use the philosophy adopted in the Guanabara Bay and Pecem Flexible Terminals design as a standard to future installations, integrated with improvements brought by the operation experience that will be obtained in those terminals. (author)

  8. 100-Meter Resolution Tree Canopy of Alaska - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This map layer contains tree canopy data for Alaska, in an Albers Equal-Area Conic projection and at a resolution of 100 meters. The tree canopy data were derived...

  9. Color Alaska Shaded Relief ? 200-Meter Resolution - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The color Alaska shaded relief data were derived from National Elevation Dataset (NED) data, and show the terrain of Alaska at a resolution of 200 meters. The NED is...

  10. Color Hawaii Shaded Relief ? 200-Meter Resolution - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The color Hawaii shaded relief data were derived from National Elevation Dataset (NED) data, and show the terrain of Hawaii at a resolution of 200 meters. The NED is...

  11. 100-Meter Resolution Color Shaded Relief of Hawaii - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The Color Shaded Relief of Hawaii map layer is a 100-meter resolution color-sliced elevation image of Hawaii, with relief shading added to accentuate terrain...

  12. 100-Meter Resolution Color Shaded Relief of Alaska - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The Color Shaded Relief of Alaska map layer is a 100-meter resolution color-sliced elevation image of Alaska, with relief shading added to accentuate terrain...

  13. 100-Meter Resolution Satellite View of Alaska - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The Satellite View of Alaska map layer is a 100-meter resolution simulated natural-color image of Alaska. Vegetation is generally green, with forests in darker green...

  14. Smarter energy from smart metering to the smart grid

    CERN Document Server

    Sun, Hongjian; Poor, H Vincent; Carpanini, Laurence; Fornié, Miguel Angel Sánchez

    2016-01-01

    This book presents cutting-edge perspectives and research results in smart energy spanning multiple disciplines across four main topics: smart metering, smart grid modeling, control and optimisation, and smart grid communications and networking.

  15. A Prediction-based Smart Meter Data Generator

    DEFF Research Database (Denmark)

    Iftikhar, Nadeem; Liu, Xiufeng; Nordbjerg, Finn Ebertsen

    2016-01-01

    With the prevalence of cloud computing and In-ternet of Things (IoT), smart meters have become one of the main components of smart city strategy. Smart meters generate large amounts of fine-grained data that is used to provide useful information to consumers and utility companies for decision......-making. Now-a-days, smart meter analytics systems consist of analytical algorithms that process massive amounts of data. These analytics algorithms require ample amounts of realistic data for testing and verification purposes. However, it is usually difficult to obtain adequate amounts of realistic data......, mainly due to privacy issues. This paper proposes a smart meter data generator that can generate realistic energy consumption data by making use of a small real-world dataset as seed. The generator generates data using a prediction-based method that depends on historical energy consumption patterns along...

  16. A Prediction-based Smart Meter Data Generator

    DEFF Research Database (Denmark)

    Iftikhar, Nadeem; Nordbjerg, Finn Ebertsen

    2016-01-01

    With the prevalence of cloud computing and Internet of Things (IoT), smart meters have become one of the main components of smart city strategy. Smart meters generate large amounts of fine-grained data that is used to provide useful information to consumers and utility companies for decisionmaking....... Now-a-days, smart meter analytics systems consist of analytical algorithms that process massive amounts of data. These analytics algorithms require ample amounts of realistic data for testing and verification purposes. However, it is usually difficult to obtain adequate amounts of realistic data......, mainly due to privacy issues. This paper proposes a smart meter data generator that can generate realistic energy consumption data by making use of a small real-world data set as seed. The generator generates data using a prediction-based method that depends on historical energy consumption patterns...

  17. Solutions For Smart Metering Under Harsh Environmental Condicions

    Directory of Open Access Journals (Sweden)

    Kunicina N.

    2015-02-01

    Full Text Available The described case study concerns application of wireless sensor networks to the smart control of power supply substations. The solution proposed for metering is based on the modular principle and has been tested in the intersystem communication paradigm using selectable interface modules (IEEE 802.3, ISM radio interface, GSM/GPRS. The solution modularity gives 7 % savings of maintenance costs. The developed solution can be applied to the control of different critical infrastructure networks using adapted modules. The proposed smart metering is suitable for outdoor installation, indoor industrial installations, operation under electromagnetic pollution, temperature and humidity impact. The results of tests have shown a good electromagnetic compatibility of the prototype meter with other electronic devices. The metering procedure is exemplified by operation of a testing company's workers under harsh environmental conditions.

  18. Solutions For Smart Metering Under Harsh Environmental Condicions

    Science.gov (United States)

    Kunicina, N.; Zabasta, A.; Kondratjevs, K.; Asmanis, G.

    2015-02-01

    The described case study concerns application of wireless sensor networks to the smart control of power supply substations. The solution proposed for metering is based on the modular principle and has been tested in the intersystem communication paradigm using selectable interface modules (IEEE 802.3, ISM radio interface, GSM/GPRS). The solution modularity gives 7 % savings of maintenance costs. The developed solution can be applied to the control of different critical infrastructure networks using adapted modules. The proposed smart metering is suitable for outdoor installation, indoor industrial installations, operation under electromagnetic pollution, temperature and humidity impact. The results of tests have shown a good electromagnetic compatibility of the prototype meter with other electronic devices. The metering procedure is exemplified by operation of a testing company's workers under harsh environmental conditions.

  19. Design and Implementation of Smart Electrical Power Meter System

    OpenAIRE

    Mofeed Turky Rashid

    2014-01-01

    In recent years, increased importance of Smart Grid, which includes monitoring and control the consumption of customers of electric power. In this paper, Wireless Smart Electrical Power Meter has been designed and implemented which ZigBee wireless sensor network (WSN) will be used for wireless electrical power meter communication supported by PIC microcontroller which used for power unit measurements. PIC microcontroller will be used for evaluating all electric power paramet...

  20. Remote calibration system of a smart electrical energy meter

    Directory of Open Access Journals (Sweden)

    Zakariae Jebroni

    2017-12-01

    Full Text Available The need to control the power grid in real time has opened a new field of research, today researchers are trying to design electrical meters that are completely remote controlled, to create an advanced metering infrastructure. One of the most important processes in the field of measurement is the calibration of measuring instruments. The calibration process of the electrical meters was performed at laboratories. However, the new directives, now, require a regular test of accuracy. Nevertheless, moving each time on site to check the accuracy of a meter can be annoying. To solve this problem our contribution is to propose a new structure of a smart meter that integrates a calibration card, so that, this process is carried out remotely. To be able to calibrate the meter or test its accuracy, we have included an AC-AC converter powered by the electrical grid and that provides a stable voltage independent of the electrical grid in term of frequency and amplitude. The output voltage of the converter is used as the reference signal during calibration or accuracy testing. In this paper, we will present the structure of the calibration card, the study and dimensioning of the converter, as well as the control technique used to eliminate variations of the input voltage. At the end, we will present the results of simulations and experiments.

  1. A case report of radiation-induced leiomyosarcoma (G-CSF producting type) of the rectum, 17 years after irradiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, Masaichi; Ikeuchi, Kenji; Takeyama, Hiroshi; Misawa, Takeyuki; Sato, Shuji; Kurosawa, Kouji; Anazawa, Sadao; Yamazaki, Yoji [Jikei Univ., Tokyo (Japan). School of Medicine

    2001-07-01

    We report a rare case of granulocyte colony-stimulating factor (G-CSF) producing rectal leiomyosarcoma that developed following pelvic irradiation for uterine cervical cancer after elapsing for 17 years. The patient was a 59-year-old woman, who had undergone uterectomy and pelvic irradiation for uterine cervical cancer at the age of 42. For eight years from 1991 when she was 51 years old, she had been diagnosed as having ileus several times, which had been treated conservatively. This time, she was admitted to the hospital because of rectovesical fistula, and she was diagnosed as having a pelvic tumor on imaging procedures. So a T-colon colostomy following by 2nd operation was performed with a month interval. After the operation, she became to eat foods by mouth smoothly in a few week, but died from a rapid growth of the liver metastatic foci, peritoneal dissemination, and septicemia only three months after the last operation. The G-CSF producing leiomyosarcoma is very rare and its prognosis is so poor. The strict following after radiation therapy might be essential and treatments based on QOL would be mandatory for such advanced type of disease. (author)

  2. Comparison of anti-inflammatory activity of extracts with supercritical carbon dioxide from radiation mutant perilla frutescens(L.) Britton and wild-type

    Energy Technology Data Exchange (ETDEWEB)

    Park, Han Chul; So, Yang Kang; Kim, Jin Baek; Jin, Chang Hyun [Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup (Korea, Republic of); Yuk, Hong Sun [Dept. of Food and Nutrition, Chungnam National University Daejeon (Korea, Republic of)

    2016-11-15

    In previous study, the radiation mutant Perilla frutescens (L.) Britton with a higher anti-inflammatory activity was selected. The extracts were obtained from the mutant and wildtype using a supercritical carbon dioxide technique. This study aimed to compare the antiinflammatory activities between the mutant supercritical extract (MSE) and wild-type supercritical extract (WSE). The contents of isoegomaketone (IK) of MSE and WSE were measured through an HPLC analysis. MSE contained IK contents approximately 7-fold higher than those of WSE. To compare the anti-inflammatory activities of MSE and WSE, the expression levels of the mRNA and protein of pro-inflammatory mediators were measured in lipopolysaccharide (LPS)-induced RAW264.7 cells. As a result, MSE inhibited the expression levels of the mRNA and protein of pro-inflammatory mediators, including inducible nitric oxide synthase (iNOS), interleukin-6 (IL-6), tumor necrosis factor-α (TNF-α), and monocyte chemoattractant protein-1 (MCP-1) to a much greater extent than did WSE. Taken together, MSE had more IK contents and higher antiinflammatory activities than WSE. Therefore, MSE is proposed based on its therapeutic potential in the prevention of inflammatory disease.

  3. Correlation of breast recurrence (inflammatory type or not) after breast conserving surgery with radiation therapy and clinicopathological factors in breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, Reiki [Kumamoto City Hospital (Japan); Koyama, Hiroki

    1998-09-01

    To clarify risk factors for breast recurrence of inflammatory type after breast conserving therapy, we examined clinicopathological findings and therapies given after initial surgery. Nine cases of inflammatory breast recurrence out of 133 recurrent cases collected from a collaborative group supported by a grant-in-aid for Cancer Research by Japanese Ministry of Health and Welfare (7-24, Chairman: H. Koyama) were analyzed by a case control study. And forty-three recurrent cases in Kumamoto City Hospital were also analyzed similarly. Inflammatory breast recurrence after breast conserving surgery is characterized as follows: Most cases have negative surgical margin and may be unresponsive to radiation therapy, unlike non-inflammatory breast recurrence. Lymph node metastasis is involved in recurrence, but the difference in patients with only distant metastasis was positive lymphatic invasion. Distant metastasis coexisted at the time of recurrence, and secondary surgery was impossible in most cases. The prognosis after recurrence was unfavorable. These findings suggest that inflammatory recurrence is manifestation of so-called ``occult`` inflammatory breast cancer. (author)

  4. Dynamic Hardness Tester and Cure Meter

    Science.gov (United States)

    Madigosky, Walter M.; Fiorito, Ralph B.

    1993-01-01

    The Shore hardness tester is used extensively throughout industry to determine the static modulus of materials. The new apparatus described here extends the capability of an indentor-type tester into the dynamic regime, and provides a measurement of the dynamic shear or Young's modulus and loss factor as a function of frequency. The instrument, model and data of typical rubber samples are given and compared to other dynamic measurements.

  5. Overview of the atmospheric ionizing radiation environment monitoring by Bulgarian build instruments

    Science.gov (United States)

    Dachev, Tsvetan; Tomov, Borislav; Matviichuk, Yury; Dimitrov, Plamen; Spurny, Frantisek; Ploc, Ondrej; Uchihori, Yukio; Flueckiger, Erwin; Kudela, Karel; Benton, Eric

    2012-10-01

    Humans are exposed to ionizing radiation all the time, and it is known that it can induce a variety of harmful biological effects. Consequently, it is necessary to quantitatively assess the level of exposure to this radiation as the basis for estimating risks for their health. Spacecraft and aircraft crews are exposed to elevated levels of cosmic radiation of galactic and solar origin and to secondary radiation produced in the atmosphere, the vehicle structure and its contents. The aircraft crew monitoring is required by the following recommendations of the International Commission on Radiological Protection (ICRP) (ICRP 1990), the European Union (EU) introduced a revised Basic Safety Standards Directive (EC 1997) which, inter alia, included the exposure to cosmic radiation. This approach has been also adopted in other official documents (NCRP 2002). In this overview we present the results of ground based, mountain peaks, aircraft, balloon and rocket radiation environment monitoring by means of a Si-diode energy deposition spectrometer Liulin type developed first in Bulgarian Academy of Sciences (BAS) for the purposes of the space radiation monitoring at MIR and International Space Station (ISS). These spectrometers-dosemeters are further developed, calibrated and used by scientific groups in different countries. Calibration procedures of them are performed at different accelerators including runs in the CERN high-energy reference field, simulating the radiation field at 10 km altitude in the atmosphere and with heavy ions in Chiba, Japan HIMAC accelerator were performed also. The long term aircraft data base were accumulated using specially developed battery operated instrument in 2001-2009 years onboard of A310-300 aircrafts of Czech Air Lines, during 24 about 2 months runs with more than 2000 flights and 13500 flight hours on routes over the Atlantic Ocean mainly. The obtained experimental data are compared with computational models like CARI and EPCARD. The

  6. Neural processing of musical meter in musicians and non-musicians.

    Science.gov (United States)

    Zhao, T Christina; Lam, H T Gloria; Sohi, Harkirat; Kuhl, Patricia K

    2017-11-01

    Musical sounds, along with speech, are the most prominent sounds in our daily lives. They are highly dynamic, yet well structured in the temporal domain in a hierarchical manner. The temporal structures enhance the predictability of musical sounds. Western music provides an excellent example: while time intervals between musical notes are highly variable, underlying beats can be realized. The beat-level temporal structure provides a sense of regular pulses. Beats can be further organized into units, giving the percept of alternating strong and weak beats (i.e. metrical structure or meter). Examining neural processing at the meter level offers a unique opportunity to understand how the human brain extracts temporal patterns, predicts future stimuli and optimizes neural resources for processing. The present study addresses two important questions regarding meter processing, using the mismatch negativity (MMN) obtained with electroencephalography (EEG): 1) how tempo (fast vs. slow) and type of metrical structure (duple: two beats per unit vs. triple: three beats per unit) affect the neural processing of metrical structure in non-musically trained individuals, and 2) how early music training modulates the neural processing of metrical structure. Metrical structures were established by patterns of consecutive strong and weak tones (Standard) with occasional violations that disrupted and reset the structure (Deviant). Twenty non-musicians listened passively to these tones while their neural activities were recorded. MMN indexed the neural sensitivity to the meter violations. Results suggested that MMNs were larger for fast tempo and for triple meter conditions. Further, 20 musically trained individuals were tested using the same methods and the results were compared to the non-musicians. While tempo and meter type similarly influenced MMNs in both groups, musicians overall exhibited significantly reduced MMNs, compared to their non-musician counterparts. Further analyses

  7. A Dedicated Mixture Model for Clustering Smart Meter Data: Identification and Analysis of Electricity Consumption Behaviors

    Directory of Open Access Journals (Sweden)

    Fateh Nassim Melzi

    2017-09-01

    Full Text Available The large amount of data collected by smart meters is a valuable resource that can be used to better understand consumer behavior and optimize electricity consumption in cities. This paper presents an unsupervised classification approach for extracting typical consumption patterns from data generated by smart electric meters. The proposed approach is based on a constrained Gaussian mixture model whose parameters vary according to the day type (weekday, Saturday or Sunday. The proposed methodology is applied to a real dataset of Irish households collected by smart meters over one year. For each cluster, the model provides three consumption profiles that depend on the day type. In the first instance, the model is applied on the electricity consumption of users during one month to extract groups of consumers who exhibit similar consumption behaviors. The clustering results are then crossed with contextual variables available for the households to show the close links between electricity consumption and household socio-economic characteristics. At the second instance, the evolution of the consumer behavior from one month to another is assessed through variations of cluster sizes over time. The results show that the consumer behavior evolves over time depending on the contextual variables such as temperature fluctuations and calendar events.

  8. Radiation levels from computer monitor screens within Benue State ...

    African Journals Online (AJOL)

    Investigation of possible presence of soft X-ray levels from Computer Screens at distances of 0.5m and 1.0m was carried out within Benue State University, Makurdi, using ten different monitor models. Radiation measurement was carried out using a portable digital radiation meter, INSPECTOR 06250 (SE international Inc.

  9. The expression of human papillomavirus type 16 (HPV16 E7) induces cell cycle arrest and apoptosis in radiation and hypoxia resistant glioblastoma cells.

    Science.gov (United States)

    Moon, Sung-Ung; Choi, Soo Kyoung; Kim, Han Jo; Kumar Bokara, Kiran; Park, Kyung Ah; Lee, Won Taek; Lee, Jong-Eun

    2011-01-01

    p53 is a widely known tumor-suppressor gene product that plays a key role in apoptotic cell death induced by DNA-damaging chemotherapeutic agents. Human glioma cells with functional p53 are known to be more resistant to γ-radiation. The aim of this study was to investigate whether the mutant glioblastoma cells (U87MG) transfected with human papilloma virus-type 16 E7 (HPV16 E7) genes were capable of increasing sensitivity towards irradiation and hypoxia-induced cell death. The pLXSN retroviral vector expressed HPV-16E7 genes and was infected into the p53 mutated U87MG cell line. A specific amplification band of HPV16 E7 genes was detected in E7 genes and transfected in the U87MG cell line using a reverse transcriptase polymerase chain reaction. The experimental groups included the mutant glioblastoma cell line (U87MG), empty vector (pLXSN) transfected to mutant glioblastoma cell line (U87MG-LXSN), and retrovirus carrying HPV16 E7 genes transfected to the mutant glioblastoma cell line (U87MG-E7). Hypoxic conditions were optimized using LDH assay and the subjects were exposed to hypoxia (16 and 20 h) and irradiation (9 h). Hoechst-propidium iodide (PI) staining results showed that hypoxia and irradiation increased the number of dead cells in the U87MG-E7 cells compared to U87MG and U87MG-LXSN cells. Results of the FACS analysis showed a similar pattern and recorded 80.44 and 58.94% of apoptotic cells in U87MG-E7 and U87MG cells, respectively. Cell cycle analysis by FACS revealed that, following irradiation and hypoxia, cells showed G2-M arrest. Additionally, the Western blot analysis results showed altered expression of E2F-1, Rb and p53 in the irradiation- and hypoxia-induced U87MG-E7 cells compared to U87MG and U87MG LXSN cells. In conclusion, the over-expression of HPV16 E7 genes in U87MG cell lines increasd cell apoptosis and E2F1 expression compared to the HPV non-infected U87MG cells following irradiation and hypoxia. These results indicate that tumor

  10. Acute radiation syndrome caused by accidental radiation exposure - therapeutic principles

    Directory of Open Access Journals (Sweden)

    Dörr Harald

    2011-11-01

    Full Text Available Abstract Fortunately radiation accidents are infrequent occurrences, but since they have the potential of large scale events like the nuclear accidents of Chernobyl and Fukushima, preparatory planning of the medical management of radiation accident victims is very important. Radiation accidents can result in different types of radiation exposure for which the diagnostic and therapeutic measures, as well as the outcomes, differ. The clinical course of acute radiation syndrome depends on the absorbed radiation dose and its distribution. Multi-organ-involvement and multi-organ-failure need be taken into account. The most vulnerable organ system to radiation exposure is the hematopoietic system. In addition to hematopoietic syndrome, radiation induced damage to the skin plays an important role in diagnostics and the treatment of radiation accident victims. The most important therapeutic principles with special reference to hematopoietic syndrome and cutaneous radiation syndrome are reviewed.

  11. Effects of radiation-counselling convergence education on radiation awareness

    Energy Technology Data Exchange (ETDEWEB)

    Seoung, Youl Hun [Dept. of Radiological Science, College of Health Science, Cheongju University, Cheongju (Korea, Republic of)

    2017-06-15

    The purpose of study was to analysis on the effects of radiation-counselling convergence education on radiation awareness. The survey objects were students of radiation-counselling convergence education from 12th May to 22th June in 2016. The questionnaires were education satisfactions and radiation awareness (risk, benefit, control) by Likert-type 5 scales. The analysis results revealed that education satisfactions of men students showed a significant higher female students and correlation coefficient of education satisfactions were the best high in the benefit and control of radiation. Finally radiation-counselling convergence education had a significant effect on radiation benefit. This convergence education influenced positive recognition on radiation benefit and it was indicated that radiation-counselors could treat clients on the basis of radiation benefit.

  12. Terrestrial Gamma Radiation Dose Rate of West Sarawak

    Science.gov (United States)

    Izham, A.; Ramli, A. T.; Saridan Wan Hassan, W. M.; Idris, H. N.; Basri, N. A.

    2017-10-01

    A study of terrestrial gamma radiation (TGR) dose rate was conducted in west of Sarawak, covering Kuching, Samarahan, Serian, Sri Aman, and Betong divisions to construct a baseline TGR dose rate level data of the areas. The total area covered was 20,259.2 km2, where in-situ measurements of TGR dose rate were taken using NaI(Tl) scintillation detector Ludlum 19 micro R meter NaI(Tl) approximately 1 meter above ground level. Twenty-nine soil samples were taken across the 5 divisions covering 26 pairings of 9 geological formations and 7 soil types. A hyperpure Germanium detector was then used to find the samples' 238U, 232Th, and 40K radionuclides concentrations producing a correction factor Cf = 0.544. A total of239 measured data were corrected with Cf resulting in a mean Dm of 47 ± 1 nGy h-1, with a range between 5 nGy h-1 - 103 nGy h-1. A multiple regression analysis was conducted between geological means and soil types means against the corrected TGR dose rate Dm, generating Dg,s= 0.847Dg+ 0.637Ds- 22.313 prediction model with a normalized Beta equation of Dg,s= 0.605Dg+ 0.395Ds. The model has an 84.6% acceptance of Whitney- Mann test null hypothesis when tested against the corrected TGR dose rates.

  13. High Accuracy Radiation TSP-type Thermometers for Radiometric Scale Realization in the Temperature Range from 600 to 3200 °C

    Science.gov (United States)

    Samoylov, M. L.; Ogarev, S. A.; Khlevnoy, B. B.; Khromchenko, V. B.; Mekhontsev, S. N.; Sapritsky, V. I.

    2003-09-01

    We have designed at VNIIOFI a high-accuracy radiation thermometer, model TSP-2 (Transfer Standard Pyrometer), for radiometric scale dissemination within the temperature range from 600°C to 3200 °C. This thermometer has been recently modified and investigated. The new TSP-4 model of radiation thermometer is under development now.

  14. A novel-type tunable and narrowband extreme ultraviolet radiation source based on high-harmonic conversion of picosecond laser pulses

    NARCIS (Netherlands)

    Barkauskas, M.; Brandi, F.; Giammanco, F.; Neshev, D.; Pirri, A.; Ubachs, W.M.G.

    2005-01-01

    At the Laser Centre Vrije Universiteit a table-top size, tunable and narrowband laser-based source of extreme ultraviolet radiation was developed using high-harmonic generation of powerful laser pulses of 300 ps duration and Fourier-transform limited bandwidth. The generated radiation has

  15. MHD free convection flow of a visco-elastic (Kuvshiniski type dusty gas through a semi infinite plate moving with velocity decreasing exponentially with time and radiative heat transfer

    Directory of Open Access Journals (Sweden)

    Om Prakash

    2011-06-01

    Full Text Available The present paper is concerned with the study of MHD free convective flow of a visco-elastic (Kuvshinski type dusty gas through a porous medium induced by the motion of a semi-infinite flat plate under the influence of radiative heat transfer moving with velocity decreasing exponentially with time. The expressions for velocity distribution of a dusty gas and dust particles, concentration profile and temperature field are obtained. The effect of Schmidt number (Sc, Magnetic field parameter (M and Radiation parameter (N on velocity distribution of dusty gas and dust particles, concentration and temperature distribution are discussed graphically.

  16. Tooth color measurement using Chroma Meter: techniques, advantages, and disadvantages.

    Science.gov (United States)

    Li, Yiming

    2003-01-01

    Tooth whitening has become a popular and routine dental procedure, and its efficacy and safety have been well documented. However, the measurement of tooth color, particularly in the evaluation of the efficacy of a system intended to enhance tooth whiteness, remains a challenge. One of the instruments used for assessing tooth color in clinical whitening studies is the Minolta Chroma Meter CR-321 (Minolta Corporation USA, Ramsey, NJ, USA). This article describes the instrument and discusses various measuring procedures and the Chroma Meter's advantages, limitations, and disadvantages. The available information indicates that, although Minolta Chroma Meter CR-321 provides quantitative and objective measurements of tooth color, it can be tedious to use with a custom alignment device. The Chroma Meter data are inconsistent with the commonly used visual instruments such as Vitapan Classical Shade Guide (Vita Zahnfabrik, Bad Säckingen, Germany), although in many cases the general trends are similar. It is also questionable whether the small area measured adequately represents the color of the whole tooth. A more critical challenge is the lack of methods for interpreting the Chroma Meter data regarding tooth color change in studies evaluating the efficacy of whitening systems. Consequently, at present the Chroma Meter data alone do not appear to be adequate for determining tooth color change in whitening research, although the quantitative measurements may be useful as supplemental or supportive data. Research is needed to develop and improve the instrument and technique for quantitative measurement of tooth color and interpretation of the data for evaluating tooth color change. This paper will help readers to understand the advantages and limitations of the Minolta Chroma Meter used for evaluating the efficacy of tooth-whitening systems so that proper judgment can be made in the interpretation of the results of clinical studies.

  17. Radiation Therapy

    Science.gov (United States)

    Radiation therapy is a cancer treatment. It uses high doses of radiation to kill cancer cells and stop them from ... half of all cancer patients receive it. The radiation may be external, from special machines, or internal, ...

  18. The Use of a Chlorophyll Meter (SPAD-502) for Field Determinations of Red Mangrove (Rhizophora Mangle L.) Leaf Chlorophyll Amount

    Science.gov (United States)

    Connelly, Xana M.

    1997-01-01

    The red mangrove Rhizophora mangle L., is a halophytic woody spermatophyte common to the land-sea interface of tropical and subtropical intertidal zones. It has been reported that 60 to 75% of the coastline of the earth's tropical regions are lined with mangroves. Mangroves help prevent shoreline erosion, provide breeding, nesting and feeding areas for many marine animals and birds. Mangroves are important contributors of primary production in the coastal environment, and this is largely proportional to the standing crop of leaf chlorophylls. Higher intensities of ultraviolet radiation, resulting from stratospheric ozone depletion, can lead to a reduction of chlorophyll in terrestrial plants. Since the most common method for determining chlorophyll concentration is by extraction and this is labor intensive and time consuming, few studies on photosynthetic pigments of mangroves have been reported. Chlorophyll meter readings have been related to leaf chlorophyll content in apples and maples. It has also been correlated to nitrogen status in corn and cotton. Peterson et al., (1993) used a chlorophyll meter to detect nitrogen deficiency in crops and in determining the need for additional nitrogen fertilizer. Efforts to correlate chlorophyll meter measurements to chlorophyll content of mangroves have not been reported. This paper describes the use of a hand-held chlorophyll meter (Minolta SPAD-502) to determine the amount of red mangrove foliar chlorophyll present in the field.

  19. Whole breast radiation therapy

    Science.gov (United States)

    ... 11, 2016. www.cancer.gov/types/breast/hp/breast-treatment-pdq . Accessed September 13, 2016. National Cancer Institute. Radiation therapy and you: support for people who have cancer. Cancer.gov Web ...

  20. Radiation dosimetry

    CERN Document Server

    Hine, Gerald J; Hine, Gerald J

    1956-01-01

    Radiation Dosimetry focuses on the advancements, processes, technologies, techniques, and principles involved in radiation dosimetry, including counters and calibration and standardization techniques. The selection first offers information on radiation units and the theory of ionization dosimetry and interaction of radiation with matter. Topics include quantities derivable from roentgens, determination of dose in roentgens, ionization dosimetry of high-energy photons and corpuscular radiations, and heavy charged particles. The text then examines the biological and medical effects of radiation,

  1. Aesthetic and emotional effects of meter and rhyme in poetry.

    Science.gov (United States)

    Obermeier, Christian; Menninghaus, Winfried; von Koppenfels, Martin; Raettig, Tim; Schmidt-Kassow, Maren; Otterbein, Sascha; Kotz, Sonja A

    2013-01-01

    Metrical patterning and rhyme are frequently employed in poetry but also in infant-directed speech, play, rites, and festive events. Drawing on four line-stanzas from nineteenth and twentieth German poetry that feature end rhyme and regular meter, the present study tested the hypothesis that meter and rhyme have an impact on aesthetic liking, emotional involvement, and affective valence attributions. Hypotheses that postulate such effects have been advocated ever since ancient rhetoric and poetics, yet they have barely been empirically tested. More recently, in the field of cognitive poetics, these traditional assumptions have been readopted into a general cognitive framework. In the present experiment, we tested the influence of meter and rhyme as well as their interaction with lexicality in the aesthetic and emotional perception of poetry. Participants listened to stanzas that were systematically modified with regard to meter and rhyme and rated them. Both rhyme and regular meter led to enhanced aesthetic appreciation, higher intensity in processing, and more positively perceived and felt emotions, with the latter finding being mediated by lexicality. Together these findings clearly show that both features significantly contribute to the aesthetic and emotional perception of poetry and thus confirm assumptions about their impact put forward by cognitive poetics. The present results are explained within the theoretical framework of cognitive fluency, which links structural features of poetry with aesthetic and emotional appraisal.

  2. Additional functions of remotely read kWh-meters

    Energy Technology Data Exchange (ETDEWEB)

    Koponen, P. [VTT Energy, Espoo (Finland); Vehvilaeinen, S. [Mittrix Oy (Finland); Rantanen, J. [Helsinki Energy Board, Helsinki (Finland)

    1996-12-31

    In this presentation the possibilities to include new applications into remotely read smart kWh-meters are considered. New electronic meters can measure various electric quantities and have some extra calculating capacity. So they can be used to provide functions that distribution automation and the customer need and thus share the costs. Some applications like monitoring the state of the distribution network or locating faults are only for the utility, but many applications also need an interface to the customer or his automation system. Among those are monitoring the quality of electricity, estimating load curves, applying dynamic tariffs and selling electricity and accounting. As a special item, the continuous monitoring of the quality of electricity is discussed. This includes voltage levels, total distortion, asymmetry and so on. If such a kWh-meter indicates quality problems the situation can be detected with a suitable portable quality meter. The poor quality can be detected before it causes harm to equipment owned by the customers or the power distribution company. This presentation also presents a prototype of such a quality monitoring kWh-meter

  3. Aesthetic and emotional effects of meter and rhyme in poetry

    Directory of Open Access Journals (Sweden)

    Christian eObermeier

    2013-01-01

    Full Text Available Metrical patterning and rhyme are frequently employed in poetry but also in infant-directed speech, play, rites, and festive events. Drawing on four line-stanzas from 19th and 20th German poetry that feature end rhyme and regular meter, the present study tested the hypothesis that meter and rhyme have an impact on aesthetic liking, emotional involvement, and affective valence attributions. Hypotheses that postulate such effects have been advocated ever since ancient rhetoric and poetics, yet they have barely been empirically tested. More recently, in the field of cognitive poetics, these traditional assumptions have been readopted in a general cognitive framework. In the present experiment, we tested the influence of meter and rhyme as well as their interaction with lexicality in the aesthetic and emotional perception of poetry. Participants listened to stanzas that were systematically modified with regard to meter and rhyme and rated them. Both rhyme and regular meter led to enhanced aesthetic appreciation, higher intensity in processing, and more positively perceived and felt emotions, with latter finding being mediated by lexicality. Together these findings clearly show that both features significantly contribute to the aesthetic and emotional perception of poetry and thus confirm assumptions about their impact put forward by cognitive poetics. The present results are explained within the theoretical framework of cognitive fluency, which links structural features of poetry with aesthetic and emotional appraisal.

  4. Strategies for Power Line Communications Smart Metering Network Deployment

    Directory of Open Access Journals (Sweden)

    Alberto Sendin

    2014-04-01

    Full Text Available Smart Grids are becoming a reality all over the world. Nowadays, the research efforts for the introduction and deployment of these grids are mainly focused on the development of the field of Smart Metering. This emerging application requires the use of technologies to access the significant number of points of supply (PoS existing in the grid, covering the Low Voltage (LV segment with the lowest possible costs. Power Line Communications (PLC have been extensively used in electricity grids for a variety of purposes and, of late, have been the focus of renewed interest. PLC are really well suited for quick and inexpensive pervasive deployments. However, no LV grid is the same in any electricity company (utility, and the particularities of each grid evolution, architecture, circumstances and materials, makes it a challenge to deploy Smart Metering networks with PLC technologies, with the Smart Grid as an ultimate goal. This paper covers the evolution of Smart Metering networks, together with the evolution of PLC technologies until both worlds have converged to project PLC-enabled Smart Metering networks towards Smart Grid. This paper develops guidelines over a set of strategic aspects of PLC Smart Metering network deployment based on the knowledge gathered on real field; and introduces the future challenges of these networks in their evolution towards the Smart Grid.

  5. The effect of ultraviolet radiation from a novel portable fluorescent lamp on serum 25-hydroxyvitamin D3 levels in healthy adults with Fitzpatrick skin types II and III.

    Science.gov (United States)

    Dabai, Nicholas S; Pramyothin, Pornpoj; Holick, Michael F

    2012-12-01

    Ultraviolet (UV) B irradiation may provide a safe and effective method to treat vitamin D deficiency. The objective of this study was to assess the effectiveness of a novel Sperti D/UV-Fluorescent lamp in converting 7-dehydrocholesterol (7-DHC) to previtamin D(3) in vitro and in raising serum 25-hydroxyvitamin D(3) [25(OH)D(3) ] in healthy adults. The lamp was assessed in vitro using a 7-DHC solution and a human skin sample. In a prospective cohort study, five healthy adults with skin types II and III were exposed to a 0.75 minimal erythemal dose of UV radiation over ≈ 9% of body surface area three times a week for 4 weeks. The main outcomes were percentage of conversion from 7-DHC to previtamin D(3) in vitro and changes in serum 25(OH)D(3) after irradiation in vivo. A dose response between UV irradiation time and conversion of 7-DHC to previtamin D(3) was seen in the 7-DHC solution and surgically obtained human skin. The subjects had a significant increase in mean 25(OH)D(3) from 18.4 ± 8.2 to 27.3 ± 7.6 ng/ml (P < 0.001) after 4 weeks of irradiation. No adverse events occurred. The Sperti D/UV-Fluorescent lamp is effective in converting 7-DHC to previtamin D(3) in vitro and in raising serum 25(OH)D(3) in healthy adults. © 2012 John Wiley & Sons A/S.

  6. THE EFFECT OF ULTRAVIOLET RADIATION FROM A NOVEL PORTABLE FLUORESCENT LAMP ON SERUM 25-HYDROXYVITAMIN D3 LEVELS IN HEALTHY ADULTS WITH FITZPATRICK SKIN TYPES II AND III

    Science.gov (United States)

    Dabai, Nicholas S.; Pramyothin, Pornpoj; Holick, Michael F.

    2012-01-01

    Background/purpose Ultraviolet B irradiation may provide a safe and effective method to treat vitamin D deficiency. The objective of this study was to assess the effectiveness of a novel Sperti D/UV-Fluorescent lamp in converting 7-dehydrocholesterol (7-DHC) to previtamin D3 in vitro and in raising serum 25-hydroxyvitamin D3 [25(OH)D3] in healthy adults. Methods The lamp was assessed in vitro using a 7-DHC solution and a human skin sample. In a prospective cohort study, five healthy adults with skin types II and III were exposed to a 0.75 minimal erythemal dose (MED) of UV radiation over ~9% of body surface area 3 times/week for 4 weeks. The main outcomes were percentage of conversion from 7-DHC to previtamin D3 in vitro and changes in serum 25(OH)D3 after irradiation in vivo. Results A dose-response between UV irradiation time and conversion of 7-DHC to previtamin D3 was seen in the 7-DHC solution and surgically obtained human skin. The subjects had a significant increase in mean 25(OH)D3 from 18.4±8.2 to 27.3±7.6 ng/mL (P<0.001) after 4 weeks of irradiation. No adverse events occurred. Conclusion The Sperti D/UV-Fluorescent lamp is effective in converting 7-DHC to previtamin D3 in vitro and in raising serum 25(OH)D3 in healthy adults. PMID:23126292

  7. CERN radiation protection (RP) calibration facilities

    Energy Technology Data Exchange (ETDEWEB)

    Pozzi, Fabio

    2016-04-14

    Radiation protection calibration facilities are essential to ensure the correct operation of radiation protection instrumentation. Calibrations are performed in specific radiation fields according to the type of instrument to be calibrated: neutrons, photons, X-rays, beta and alpha particles. Some of the instruments are also tested in mixed radiation fields as often encountered close to high-energy particle accelerators. Moreover, calibration facilities are of great importance to evaluate the performance of prototype detectors; testing and measuring the response of a prototype detector to well-known and -characterized radiation fields contributes to improving and optimizing its design and capabilities. The CERN Radiation Protection group is in charge of performing the regular calibrations of all CERN radiation protection devices; these include operational and passive dosimeters, neutron and photon survey-meters, and fixed radiation detectors to monitor the ambient dose equivalent, H*(10), inside CERN accelerators and at the CERN borders. A new state-of-the-art radiation protection calibration facility was designed, constructed and commissioned following the related ISO recommendations to replace the previous ageing (more than 30 years old) laboratory. In fact, the new laboratory aims also at the official accreditation according to the ISO standards in order to be able to release certified calibrations. Four radiation fields are provided: neutrons, photons and beta sources and an X-ray generator. Its construction did not only involve a pure civil engineering work; many radiation protection studies were performed to provide a facility that could answer the CERN calibration needs and fulfill all related safety requirements. Monte Carlo simulations have been confirmed to be a valuable tool for the optimization of the building design, the radiation protection aspects, e.g. shielding, and, as consequence, the overall cost. After the source and irradiator installation

  8. Relative Biological Effectiveness of Energetic Heavy Ions for Intestinal Tumorigenesis Shows Male Preponderance and Radiation Type and Energy Dependence in APC{sup 1638N/+} Mice

    Energy Technology Data Exchange (ETDEWEB)

    Suman, Shubhankar; Kumar, Santosh; Moon, Bo-Hyun; Strawn, Steve J.; Thakor, Hemang; Fan, Ziling [Department of Biochemistry and Molecular & Cellular Biology and Lombardi Comprehensive Cancer Center, Georgetown University, Washington, District of Columbia (United States); Shay, Jerry W. [Department of Cell Biology, UT Southwestern Medical Center, Dallas, Texas (United States); Fornace, Albert J. [Department of Biochemistry and Molecular & Cellular Biology and Lombardi Comprehensive Cancer Center, Georgetown University, Washington, District of Columbia (United States); Center of Excellence in Genomic Medicine Research (CEGMR), King Abdulaziz University, Jeddah (Saudi Arabia); Datta, Kamal, E-mail: kd257@georgetown.edu [Department of Biochemistry and Molecular & Cellular Biology and Lombardi Comprehensive Cancer Center, Georgetown University, Washington, District of Columbia (United States)

    2016-05-01

    Purpose: There are uncertainties associated with the prediction of colorectal cancer (CRC) risk from highly energetic heavy ion (HZE) radiation. We undertook a comprehensive assessment of intestinal and colonic tumorigenesis induced after exposure to high linear energy transfer (high-LET) HZE radiation spanning a range of doses and LET in a CRC mouse model and compared the results with the effects of low-LET γ radiation. Methods and Materials: Male and female APC{sup 1638N/+} mice (n=20 mice per group) were whole-body exposed to sham-radiation, γ rays, {sup 12}C, {sup 28}Si, or {sup 56}Fe radiation. For the >1 Gy HZE dose, we used γ-ray equitoxic doses calculated using relative biological effectiveness (RBE) determined previously. The mice were euthanized 150 days after irradiation, and intestinal and colon tumor frequency was scored. Results: The highest number of tumors was observed after {sup 28}Si, followed by {sup 56}Fe and {sup 12}C radiation, and tumorigenesis showed a male preponderance, especially after {sup 28}Si. Analysis showed greater tumorigenesis per unit of radiation (per cGy) at lower doses, suggesting either radiation-induced elimination of target cells or tumorigenesis reaching a saturation point at higher doses. Calculation of RBE for intestinal and colon tumorigenesis showed the highest value with {sup 28}Si, and lower doses showed greater RBE relative to higher doses. Conclusions: We have demonstrated that the RBE of heavy ion radiation-induced intestinal and colon tumorigenesis is related to ion energy, LET, gender, and peak RBE is observed at an LET of 69 keV/μm. Our study has implications for understanding risk to astronauts undertaking long duration space missions.

  9. Radiation exposure and pregnancy.

    Science.gov (United States)

    Labant, Amy; Silva, Christina

    2014-01-01

    Radiological exposure from nuclear power reactor accidents, transportation of nuclear waste accidents, industrial accidents, or terrorist activity may be a remote possibility, but it could happen. Nurses must be prepared to evaluate and treat pregnant women and infants who have been exposed to radiation, and to have an understanding of the health consequences of a nuclear or radiological incident. Pregnant women and infants are a special group of patients who need consideration when exposed to radiation. Initial care requires thorough assessment and decisions regarding immediate care needs. Ongoing care is based on type and extent of radiation exposure. With accurate, comprehensive information and education, nurses will be better prepared to help mitigate the effects of radiation exposure to pregnant women and infants following a radiological incident. Information about radiation, health effects of prenatal radiation exposure, assessment, patient care, and treatment of pregnant women and infants are presented.

  10. Advanced Metering Implementations - A Perspective from Federal Sector

    Energy Technology Data Exchange (ETDEWEB)

    Eaarni, Shankar

    2014-08-11

    Federal mandate (EPACT 2005) requires that federal buildings install advanced electrical meters-meters capable of providing data at least daily and measuring the consumption of electricity at least hourly. This work presents selected advanced metering implementations to understand some of the existing practices related to data capture and to understand how the data is being translated into information and knowledge that can be used to improve building energy and operational performance to meet federal energy reduction mandates. This study highlights case studies to represent some of the various actions that are being taken based on the data that are being collected to improve overall energy performance of these buildings. Some of these actions include- individualized tenant billing and energy forecasting, benchmarking, identifying energy conservation measures, measurement and verification.

  11. Privacy, technology, and norms: the case of Smart Meters.

    Science.gov (United States)

    Horne, Christine; Darras, Brice; Bean, Elyse; Srivastava, Anurag; Frickel, Scott

    2015-05-01

    Norms shift and emerge in response to technological innovation. One such innovation is Smart Meters - components of Smart Grid energy systems capable of minute-to-minute transmission of consumer electricity use information. We integrate theory from sociological research on social norms and privacy to examine how privacy threats affect the demand for and expectations of norms that emerge in response to new technologies, using Smart Meters as a test case. Results from three vignette experiments suggest that increased threats to privacy created by Smart Meters are likely to provoke strong demand for and expectations of norms opposing the technology and that the strength of these normative rules is at least partly conditional on the context. Privacy concerns vary little with actors' demographic characteristics. These findings contribute to theoretical understanding of norm emergence and have practical implications for implementing privacy protections that effectively address concerns of electricity users. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Deducing Energy Consumer Behavior from Smart Meter Data

    Directory of Open Access Journals (Sweden)

    Emad Ebeid

    2017-07-01

    Full Text Available The ongoing upgrade of electricity meters to smart ones has opened a new market of intelligent services to analyze the recorded meter data. This paper introduces an open architecture and a unified framework for deducing user behavior from its smart main electricity meter data and presenting the results in a natural language. The framework allows a fast exploration and integration of a variety of machine learning algorithms combined with data recovery mechanisms for improving the recognition’s accuracy. Consequently, the framework generates natural language reports of the user’s behavior from the recognized home appliances. The framework uses open standard interfaces for exchanging data. The framework has been validated through comprehensive experiments that are related to an European Smart Grid project.

  13. Weapons of mass destruction: radiation.

    Science.gov (United States)

    Neal, Chris J; Moores, Leon E

    2002-03-15

    The purpose of this review is to present a concise overview of the types of radiation, methods of dispersal, injury patterns, and treatment considerations in a scenario involving radiation-based weapons of mass destruction. Radiation-related casualties, although uncommon, are a potential threat because more nations and organizations are developing the technology for producing radioactive substances capable of being used as weapons.

  14. Radiation leakage from electromagnetic oven

    Directory of Open Access Journals (Sweden)

    Abdurrahman Khalil

    2015-10-01

    Results & Discussions: The measurements have been done at some houses in Erbil city, according to the source of background radiation exist before measuring data. Our data compared with standard safe range of radiation data. Results showed that there is radiation leak form all type of electromagnetic oven and all at the order of safety compared with standard value.

  15. An electronic pressure-meter nociception paw test for mice

    Directory of Open Access Journals (Sweden)

    T.M. Cunha

    2004-03-01

    Full Text Available The aim of the present investigation was to describe and validate an electronic mechanical test for quantification of the intensity of inflammatory nociception in mice. The electronic pressure-meter test consists of inducing the animal hindpaw flexion reflex by poking the plantar region with a polypropylene pipette tip adapted to a hand-held force transducer. This method was compared to the classical von Frey filaments test in which pressure intensity is automatically recorded after the nociceptive hindpaw flexion reflex. The electronic pressure-meter and the von Frey filaments were used to detect time versus treatment interactions of carrageenin-induced hypernociception. In two separate experiments, the electronic pressure-meter was more sensitive than the von Frey filaments for the detection of the increase in nociception (hypernociception induced by small doses of carrageenin (30 µg. The electronic pressure-meter detected the antinociceptive effect of non-steroidal drugs in a dose-dependent manner. Indomethacin administered intraperitoneally (1.8-15 mg/kg or intraplantarly (30-300 µg/paw prevented the hypersensitive effect of carrageenin (100 µg/paw. The electronic pressure-meter also detected the hypernociceptive effect of prostaglandin E2 (PGE2; 10-100 ng in a dose-dependent manner. The hypernociceptive effect of PGE2 (100 ng was blocked by dipyrone (160 and 320 µg/paw but not by intraplantar administration of indomethacin (300 µg/paw. The present results validate the use of the electronic pressure-meter as more sensitive than the von Frey filaments in mice. Furthermore, it is an objective and quantitative nociceptive test for the evaluation of the peripheral antinociceptive effect of anti-inflammatory analgesic drugs, which inhibit prostaglandin synthesis (indomethacin or directly block the ongoing hypernociception (dipyrone.

  16. Optimal leaf positions for chlorophyll meter measurement in rice

    Directory of Open Access Journals (Sweden)

    Zhaofeng eYuan

    2016-05-01

    Full Text Available The Soil Plant Analysis Development (SPAD chlorophyll meter is one of the most commonly used diagnostic tools to measure crop nitrogen status. However, the measurement method of the meter could significantly affect the accuracy of the final estimation. Thus, this research was undertaken to develop a new methodology to optimize SPAD meter measurements in rice (Oryza sativa L.. A flatbed color scanner was used to map the dynamic chlorophyll distribution and irregular leaf shapes. Calculus algorithm was adopted to estimate the potential positions for SPAD meter measurement along the leaf blade. Data generated by the flatbed color scanner and SPAD meter were analysed simultaneously. The results suggested that a position 2/3 of the distance from the leaf base to the apex (2/3 position could represent the chlorophyll content of the entire leaf blade, as indicated by the relatively low variance of measurements at that positon. SPAD values based on di-positional leaves and the extracted chlorophyll a and b contents were compared. This comparison showed that the 2/3 position on the lower leaves tended to be more sensitive to changes in chlorophyll content. Finally, the 2/3 position and average SPAD values of the fourth fully expanded leaf from the top were compared with leaf nitrogen concentration. The results showed the 2/3 position on that leaf was most suitable for predicting the nitrogen status of rice. Based on these results, we recommend making SPAD measurements at the 2/3 position on the fourth fully expanded leaf from the top. The coupling of dynamic chlorophyll distribution and irregular leaf shapes information can provide a promising approach for the calibration of SPAD meter measurement, which can further benefit the in situ nitrogen management by providing reliable estimation of crops nitrogen nutrition status.

  17. The bacterial contamination rate of glucose meter test strips in the hospital setting

    Science.gov (United States)

    Al-Rubeaan, Khalid A.; Saeb, Amr T. M.; AlNaqeb, Dhekra M.; AlQumaidi, Hamed M.; AlMogbel, Turki A.

    2016-01-01

    Objectives: To assess the rate of bacterial contamination of the multi-use vial and single-use packed glucose meter strips, and to identify the type and frequency of various bacterial contamination in different hospital wards. Methods: This prospective observational study was conducted by a team from the Strategic Center for Diabetes Research in 7 general hospitals in the Central region of Saudi Arabia during the period from August to September 2014 to assess the bacterial contamination rate of the unused strips. A total of 10,447 strips were cultured using proper agar media and incubated both aerobically and anaerobically. Results: The total bacterial contamination rate for the multi-use vials glucose strips was 31.7%, while single-use packed strips were not contaminated at all. Ministry of Health hospitals had the highest contamination rates compared with other hospitals. Critical, obstetric, and surgical wards had the highest bacterial isolates number, where most were in the risk group 3 according to the National Institute of Health guidelines. Staphylococcus species were the most common bacteria found. Conclusion: Glucose meter strips should be recognized as a source of bacterial contamination that could be behind serious hospital acquired infections. The hospital infection control team should adopt proper measures to implement protocols for glucose meter cleaning and glucose strips handling. PMID:27570855

  18. Accidental Cutaneous Burns Secondary to Salbutamol Metered Dose Inhaler

    OpenAIRE

    Kale, Ashutosh; Shackley, Fiona

    2010-01-01

    We report a case of accidental cutaneous burns caused by salbutamol metered dose inhaler. A 9-year-old boy underwent dental extraction at a children's hospital and was incidentally noted to have burn injuries on dorsum of both hands. On questioning, the boy revealed that a few days ago his 14-year-old brother, who is an asthmatic, playfully sprayed his salbutamol metered dose inhaler on the back of both his hands with the inhaler's mouth piece being in direct contact with the patient's skin. ...

  19. Additional functions of remotely read kWh-meters

    Energy Technology Data Exchange (ETDEWEB)

    Koponen, P. [VTT Energy, Espoo (Finland); Vehvilaeinen, S. [Mittrix Oy (Finland); Rantanen, J. [Helsinki Energy Board (Finland)

    1998-08-01

    In this chapter the possibilities to include new applications into remotely read smart kWh-meters are considered. New electronic meters can measure various electric quantities and have some extra calculating capacity. So they can be used to provide functions that distribution automation and the customer need and thus share the costs. Some applications like monitoring the state of the distribution network or locating faults are only for the utility, but many applications also need an interface to the customers or their automation systems. Among those are monitoring the quality of electricity, estimating load curves, applying dynamic tariffs and selling electricity and accounting. As a special item, the continuous monitoring of the quality of electricity is discussed. This includes voltage levels, total distortion, asymmetry and so on. If such a kWh-meter indicates quality problems it is possible to go there with a portable quality meter that is suitable for the case and inspect the situation. The poor quality can be detected before it causes harm to equipment owned by the customers or the power distribution company. This article also presents a prototype of such a quality monitoring kWh-meter. Dynamic tariffs and free electricity markets require two way communication with the utility and the customer and measurement of the time variations of the energy consumption. The customers or their energy management system must receive the energy prices from the utility and calculate the energy costs and decide upon the energy consumption control actions. Some alternative ways to meet these customer interface requirements are compared. Remote reading of kWh-meters requires a certain investment in meters and their data communication with the utility. Because smart meters can have some additional memory and calculating capacity and are capable of measuring various electric quantities, it is possible to share the costs with other applications that use the same hardware and data

  20. Apparent losses due to domestic water meter under-registration in ...

    African Journals Online (AJOL)

    By combining these results with the average age of meters in South Africa, estimated from the National Water Demand Archive, it was possible to estimate the average meter under-registration due to meter aging. The study concluded that apparent losses due to water meter under-registration are around 5% of consumption ...

  1. Apparent losses due to domestic water meter under-registration in ...

    African Journals Online (AJOL)

    2015-10-05

    Oct 5, 2015 ... By combining these results with the average age of meters in South Africa, estimated from the National Water Demand. Archive, it was possible to estimate the average meter under-registration due to meter aging. The study concluded that apparent losses due to water meter under-registration are around ...

  2. Apparent losses due to domestic water meter under-registration in ...

    African Journals Online (AJOL)

    2015-10-05

    Oct 5, 2015 ... with the exception of one multi-jet meter. These meters were distributed in 15 and 6 different suburbs in Cape Town and. Mangaung, respectively. The reading taken from water meters in these tests included meter errors, and thus had to be corrected to determine the actual volumes. These corrections were ...

  3. Current meter data from moored current meter casts in the South Atlantic Ocean from 18 June 1992 - 29 October 1993 (NODC Accession 9700223)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter data were collected using moored current meter casts in the South Atlantic Ocean from June 18, 1992 to October 29, 1993. Data were submitted by Oregon...

  4. Current meter and temperature profile data from moored current meter casts in the TOGA area - Atlantic Ocean from 10 September 1970 - 27 October 1980 (NODC Accession 8600320)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter and temperature profile data were collected using moored current meter - PCM casts in the TOGA area - Atlantic Ocean from September 10, 1970 to October...

  5. Current meter data from moored current meter casts in the Northeast Pacific (limit - 180) from 1992-06-12 to 1994-06-20 (NODC Accession 9700237)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter data were collected using moored current meter casts in the Northeast Pacific (limit - 180) from June 12, 1992 to June 20, 1994. Data were submitted by...

  6. Security and functional requirements for the smart meter gateway; Sicherheitstechnische Vorgaben und funktionale Anforderungen an das Smart Meter Gateway

    Energy Technology Data Exchange (ETDEWEB)

    Bast, Holger; Vollmer, Stefan [Bundesamt fuer Sicherheit in der Informationstechnik, Bonn (Germany)

    2012-07-01

    The availability of smart metering for the majority of both private and corporate prosumers is an essential precondition to get smart grids into operation. However, several concerns about data protection and security issues of smart meters have been raised and discussed in German media. The German Federal Data Protection Commissioner argued that without any further precautions personal data processed in smart meters could be collected and misused by unauthorized third parties if there is no technical standard that specifies technical requirements for necessary data security functions combined with regulatory instruments to make them mandatory. The German Federal Office for Information Security develops a protection profile based on Common Criteria and Technical Guidelines that allow a comparable security certification of such devices. (orig.)

  7. Teores de clorofila determinados por medidor portátil e sua relação com formas de nitrogênio em folhas de tomateiro cultivados em dois tipos de solo Relations among chlorophyll contents determined by a portable meter and nitrogen forms in leaves of tomatoes cultivated in two soil types

    Directory of Open Access Journals (Sweden)

    TADEU GRACIOLLI GUIMARÃES

    1999-01-01

    das leituras obtidas no medidor SPAD, permitiu o ajuste de equação linear (CP = -77,233 + 3,54725** SPAD R2 = 0,766.This work aimed to determine chlorophyll concentrations of tomato (Lycopersicon esculentum Mill. plants cv. Santa Clara fertilized with five nitrogen (N rates by means of conventional laboratory methodology and by the SPAD-502 portable chlorophyll meter. The relationship between chlorophyll and N values was determined by these two methods. Tomato plants were grown in pots with a clay soil classified as Cambic Red-Yellow Podsol (CRP and a sand-course soil classified as Quartzic Sand (QS, and received five N rates (25, 125, 225, 325 and 425 mg. dm-3 sidedressed as nutrient solutions. At the onset of 3rd cluster anthesis, chlorophyll concentrations were determined in leaves opposite to this cluster by the portable chlorophyll meter SPAD-502 and at laboratory by Arnon's methodology. NO3-N was determined in petiole sap and in dry matter, while NO3-N, org-N and total-N were determined in leaf blade dry matter. Chlorophyll concentrations increased with N rates irrespective of method of determination, in both soils. Critical levels in soils CRP and QS were, respectively, 77.3 and 83.6 mg. cm-2 by laboratory methodology and 45.5 and 43.8 SPAD units by the portable meter. Correlation coefficients of chlorophyll concentrations with top dry weight and N forms were greater for the SPAD method. Both methods of chlorophyll determination presented greatest correlation with sap NO3-N in soil CRP, and with org-N and total-N in soil QS. The estimative of chlorophyll concentrations (laboratory method by means of SPAD readings allowed the adjustment of a linear equation (CP = -77.233 + 3.54725** SPAD R2 = 0.766.

  8. Look at the Beat, Feel the Meter:Top-down Effects of Meter Induction on Auditory and Visual Modalities

    Directory of Open Access Journals (Sweden)

    Alexandre eCelma-Miralles

    2016-03-01

    Full Text Available Recent research has demonstrated top-down effects on meter induction in the auditory modality. However, little is known about these effects in the visual domain, especially without the involvement of motor acts such as tapping. In the present study, we aim to assess whether the projection of meter on auditory beats is also present in the visual domain. We asked sixteen musicians to internally project binary (i.e. a strong-weak pattern and ternary (i.e. a strong-weak-weak pattern meter onto separate, but analogue, visual and auditory isochronous stimuli. Participants were presented with sequences of tones or blinking circular shapes (i.e. flashes at 2.4 Hz while their electrophysiological responses were recorded. A frequency analysis of the elicited steady-state evoked potentials allowed us to compare the frequencies of the beat (2.4 Hz, its first harmonic (4.8 Hz, the binary subharmonic (1.2 Hz, and ternary subharmonic (0.8 Hz within and across modalities. Taking the amplitude spectra into account, we observed an enhancement of the amplitude at 0.8 Hz in the ternary condition for both modalities, suggesting meter induction across modalities. There was an interaction between modality and voltage at 2.4 and 4.8 Hz. Looking at the power spectra, we also observed significant differences from zero in the auditory, but not in the visual, binary condition at 1.2 Hz. These findings suggest that meter processing is modulated by top-down mechanisms that interact with our perception of rhythmic events and that such modulation can also be found in the visual domain. The reported cross-modal effects of meter may shed light on the origins of our timing mechanisms, partially developed in primates and allowing humans to synchronize across modalities accurately.

  9. Wireless smart meters and public acceptance: the environment, limited choices, and precautionary politics.

    Science.gov (United States)

    Hess, David J; Coley, Jonathan S

    2014-08-01

    Wireless smart meters (WSMs) promise numerous environmental benefits, but they have been installed without full consideration of public acceptance issues. Although societal-implications research and regulatory policy have focused on privacy, security, and accuracy issues, our research indicates that health concerns have played an important role in the public policy debates that have emerged in California. Regulatory bodies do not recognize non-thermal health effects for non-ionizing electromagnetic radiation, but both homeowners and counter-experts have contested the official assurances that WSMs pose no health risks. Similarities and differences with the existing social science literature on mobile phone masts are discussed, as are the broader political implications of framing an alternative policy based on an opt-out choice. The research suggests conditions under which health-oriented precautionary politics can be particularly effective, namely, if there is a mandatory technology, a network of counter-experts, and a broader context of democratic contestation.

  10. How to Make the 20-cent Fallout Meter

    Energy Technology Data Exchange (ETDEWEB)

    Meade, Roger Allen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Rodriguez, Serena R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Alvarez, Luis [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-05-17

    Nobel Prize winner Luis Alvarez published an article on how to build a homemade fallout meter in the November 12, 1961, issue of the Sunday supplement This Week Magazine. A yellowed copy of the article was recently found in the files of the Radiochemistry Group, C-NR, and is reproduced below in its original form.

  11. Concepten nul op de meter en 80% besparing

    NARCIS (Netherlands)

    Jacobs, P.; Liedelmeijer, K.; Borsboom, W.A.; Vliet, M.R.A. van; Jong, P. de

    2015-01-01

    Bouwers die kiezen voor energiezuinig en Nul op de Meter staan voor een aantal uitdagingen. Zowel op sociaal, economisch en technisch gebied is er werk aan de winkel. Er wordt al gepionierd en daar kunnen we van leren. Daarom delen wij, TNO, RIGO, Van Beek, Energiesprong | Platform 31, met plezier

  12. INFLUENCE OF FUNCTIONAL ABILITY IN RUNNING 400 AND 800 METERS

    Directory of Open Access Journals (Sweden)

    Abdulla Elezi

    2013-07-01

    Full Text Available Goal of the research was to assess on the grounds of data collected that were used to assess the functional ability of the cardio-respiratory system and the results of running to determine the relation of these sum of variables. Basic statistical indicators of the physiological variables and results of running were calculated. For determining the relation, the regression analysis was used in the manifested space. Criterion variable (running for 100 meters did not demonstrate statistically significant coefficient of multiple variation with predictor variables. The time span in running 400 meters is short in order to engage mechanisms that supply and transform the energy for oxidative processes. Criterion variable (of running 800 meters has demonstrated statistically significant coefficient of multiple correlations with predictor variable and its value was 0.377 tested through F-test. This is understandable given that the time effect of engagement of systems responsible for transfer and transformation of energy compared to time needed for running 400 meters.

  13. A Status Report on the Thirty Meter Telescope Adaptive Optics ...

    Indian Academy of Sciences (India)

    2016-01-27

    Jan 27, 2016 ... We provide an update on the recent development of the adaptive optics (AO) systems for the Thirty Meter Telescope (TMT) since mid-2011. The first light AO facility for TMT consists of the Narrow Field Infra-Red AO System (NFIRAOS) and the associated Laser Guide Star Facility (LGSF). This order 60 × 60 ...

  14. 40 CFR 1065.230 - Raw exhaust flow meter.

    Science.gov (United States)

    2010-07-01

    ... flow meter. (a) Application. You may use measured raw exhaust flow, as follows: (1) Use the actual... value: (i) For feedback control of a proportional sampling system, such as a partial-flow dilution... averaging Pitot tube, a hot-wire anemometer, or other measurement principle. This would generally not...

  15. 16 reference population equations using peak expiratory flow meters

    African Journals Online (AJOL)

    DR. AMINU

    produced using PEF meters in Nigeria. 2. To highlight on the limitations observed on some of these population driven reference equations. 3. To suggest other methods to improve on the reference equations produced. Contribution of Scholars in generating PEFR prediction equations in Nigeria. Normal values of PEFR ...

  16. Accuracy of Handheld Blood Glucose Meters at High Altitude

    NARCIS (Netherlands)

    de Mol, Pieter; Krabbe, Hans G.; de Vries, Suzanna T.; Fokkert, Marion J.; Dikkeschei, Bert D.; Rienks, Rienk; Bilo, Karin M.; Bilo, Henk J. G.

    2010-01-01

    Background: Due to increasing numbers of people with diabetes taking part in extreme sports (e. g., high-altitude trekking), reliable handheld blood glucose meters (BGMs) are necessary. Accurate blood glucose measurement under extreme conditions is paramount for safe recreation at altitude. Prior

  17. Smart Grid Security A Smart Meter-Centric Perspective

    DEFF Research Database (Denmark)

    Vigo, Roberto; Yuksel, Ender; Ramli, Carroline Dewi Puspa Kencana

    2012-01-01

    , leading to what is known as the Smart Grid. The development of this Cyber-Physical System introduces new security issues, thus calling for efforts in studying possible attacks and devising suitable countermeasures. In this paper, we review a generic model for the Smart Grid, and present possible attacks...... and countermeasures focusing on a key component of the Smart Grid: the Smart Meter....

  18. Minnesota Digital Elevation Model - Tiled 30 Meter Resolution

    Data.gov (United States)

    Minnesota Department of Natural Resources — This 30 Meter DEM is a copy of the USGS 1:24,000 scale Level 2 DEMs for the State. There are three quadrangles known be be Level 1 DEM data: Town Line Lake (q1925),...

  19. An assessment of billing electricity consumers via analogue meters ...

    African Journals Online (AJOL)

    This paper assesses the perception of billing consumers via analogue meter in Kano Electricity Distribution Plc, Nigeria. Questionnaire survey was used to collect data from the consumers, frequency counts and percentages were used to analyze the generated data. The result of the study revealed that 38% of the Analogue ...

  20. Ipratropium bromide delivered by metered-dose aerosol to infant ...

    African Journals Online (AJOL)

    Two methods of administration of ipratropium bromide (Atrovent; Boehringer Ingelheim) to wheezing children'< 25 months of age were compared: (i) the conventional nebulisation (15 children); and (ii) a metered-dose aerosol plus spacer and mask (MDA group, 17 children). The drug induced a significant and similar fall in ...

  1. Meter Detection in Symbolic Music Using Inner Metric Analysis

    NARCIS (Netherlands)

    de Haas, W.B.; Volk, A.

    2016-01-01

    In this paper we present PRIMA: a new model tailored to symbolic music that detects the meter and the first downbeat position of a piece. Given onset data, the metrical structure of a piece is interpreted using the Inner Metric Analysis (IMA) model. IMA identifies the strong and weak metrical

  2. Ipratropium bromide delivered by metered-dose aerosol to infant ...

    African Journals Online (AJOL)

    1990-08-21

    Aug 21, 1990 ... metered aerosol method compared with nebulisation of ipra- tropium bromide when given to wheezing infants and toddlers. The former method is convenient for primary health care facilities or home use, since it does not depend upon the availability of the nebuliser apparatus or a gas or electricity source.

  3. Chlorophyll meter reading and total nitrogen content applied as ...

    African Journals Online (AJOL)

    The present study was aimed to assess the relationship between the reading of the chlorophyll meter and the total nitrogen (N) content in the leaf in different parts of the crambe plant, depending on the doses of nitrogen applied to the canopy. Randomized block design in a split plot experimental design was used. The plots ...

  4. Chlorophyll meter reading and total nitrogen content applied as ...

    African Journals Online (AJOL)

    Ana Mascarello

    The present study was aimed to assess the relationship between the reading of the chlorophyll meter and the total nitrogen (N) content in the leaf in different parts of the crambe plant, depending on the doses of nitrogen applied to the canopy. Randomized block design in a split-plot experimental design was used. The plots ...

  5. Index of Refraction Measurements Using a Laser Distance Meter

    Science.gov (United States)

    Ochoa, Romulo; Fiorillo, Richard; Ochoa, Cris

    2014-01-01

    We present a simple method to determine the refractive indices of transparent media using a laser distance meter. Indices of refraction have been obtained by measuring the speed of light in materials. Some speed of light techniques use time-of-flight measurements in which pulses are emitted by lasers and the time interval is measured for the pulse…

  6. Vibration isolation for Coriolis Mass-Flow meters

    NARCIS (Netherlands)

    van de Ridder, Bert

    2015-01-01

    A Coriolis Mass-Flow Meter (CMFM) is an active device based on the Coriolis force principle for direct mass-flow measurements, with high accuracy, range-ability and repeatability. The working principle of a CMFM is as follows: a fluid conveying tube is actuated to oscillate at a low amplitude. A

  7. Design and construction of a resistivity meter for shallow investigation

    African Journals Online (AJOL)

    Beyond this spread, the difference in readings is much. Hence, the use of this system is limited to shallow investigations where the target depth is not more than fifty metres (50m). Efforts are being made to improve on its performance. Keywords: Design and construction, resistivity meter and field testing. Nigerian Journal of ...

  8. Multichannel Distribution Meter: A Veritable Solution in Power ...

    African Journals Online (AJOL)

    Power theft in partitioned commercial apartments, especially in the form of unpaid bills due to disputes, is a major challenge to revenue recovery in the power sector. This paper presents a multi-channel power distribution metering solution that serves to resolve disputes among users in partitioned apartments, and between ...

  9. Performance evaluation of cognitive radio in advanced metering infrastructure communication

    Science.gov (United States)

    Hiew, Yik-Kuan; Mohd Aripin, Norazizah; Din, Norashidah Md

    2016-03-01

    Smart grid is an intelligent electricity grid system. A reliable two-way communication system is required to transmit both critical and non-critical smart grid data. However, it is difficult to locate a huge chunk of dedicated spectrum for smart grid communications. Hence, cognitive radio based communication is applied. Cognitive radio allows smart grid users to access licensed spectrums opportunistically with the constraint of not causing harmful interference to licensed users. In this paper, a cognitive radio based smart grid communication framework is proposed. Smart grid framework consists of Home Area Network (HAN) and Advanced Metering Infrastructure (AMI), while AMI is made up of Neighborhood Area Network (NAN) and Wide Area Network (WAN). In this paper, the authors only report the findings for AMI communication. AMI is smart grid domain that comprises smart meters, data aggregator unit, and billing center. Meter data are collected by smart meters and transmitted to data aggregator unit by using cognitive 802.11 technique; data aggregator unit then relays the data to billing center using cognitive WiMAX and TV white space. The performance of cognitive radio in AMI communication is investigated using Network Simulator 2. Simulation results show that cognitive radio improves the latency and throughput performances of AMI. Besides, cognitive radio also improves spectrum utilization efficiency of WiMAX band from 5.92% to 9.24% and duty cycle of TV band from 6.6% to 10.77%.

  10. Ultraviolet Radiation Emissions and Illuminance in Different Brands of Compact Fluorescent Lamps

    Directory of Open Access Journals (Sweden)

    Shahram Safari

    2015-01-01

    Full Text Available Introduction. Replacing incandescent lamps with compact fluorescent lamps (CFLs, which are three to six times more efficient, is one of the easiest methods to achieve energy efficiency. The present study aimed to evaluate relationships between UV emissions radiated and illuminance CFLs. Material and Methods. This pilot study was conducted on 16 single envelope CFLs. The illuminance and UV irradiance of various types of CFLs are measured on a three-meter long optical bench, using a calibrated lux meter and UV meter, and measurement was done in 10, 25, 50, 100, 150, and 200 cm, in three angles, including 0°, 45°, and 90°, at the ages of 0, 100, and 2000 hours. Result. UVC irradiance was not observed at the distance of 10 cm in all of lamps. The lowest value of UVB irradiance was recorded in Pars Khazar lamp, while the highest value was recorded in Etehad lamps. UVR values measured at different times showed negligible differences; the highest asset value was detected in zero times. One way ANOVA indicated that relationships between UVA irradiance and illuminance were significant (P<0.05. Conclusion. UVB irradiance in most of the lamp in 10 and 25 cm was more than occupational exposure and UVA except for the fact that Pars Khazar 60 watts and Nama Noor 60 watts were less than occupational exposure.

  11. Exploring the energy benefits of advanced water metering

    Energy Technology Data Exchange (ETDEWEB)

    Berger, Michael A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Hans, Liesel [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Piscopo, Kate [Univ. of California, Berkeley, CA (United States); Sohn, Michael D. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-08-01

    Recent improvements to advanced water metering and communications technologies have the potential to improve the management of water resources and utility infrastructure, benefiting both utilities and ratepayers. The highly granular, near-real-time data and opportunity for automated control provided by these advanced systems may yield operational benefits similar to those afforded by similar technologies in the energy sector. While significant progress has been made in quantifying the water-related benefits of these technologies, the research on quantifying the energy benefits of improved water metering is underdeveloped. Some studies have quantified the embedded energy in water in California, however these findings are based on data more than a decade old, and unanimously assert that more research is needed to further explore how topography, climate, water source, and other factors impact their findings. In this report, we show how water-related advanced metering systems may present a broader and more significant set of energy-related benefits. We review the open literature of water-related advanced metering technologies and their applications, discuss common themes with a series of water and energy experts, and perform a preliminary scoping analysis of advanced water metering deployment and use in California. We find that the open literature provides very little discussion of the energy savings potential of advanced water metering, despite the substantial energy necessary for water’s extraction, conveyance, treatment, distribution, and eventual end use. We also find that water AMI has the potential to provide water-energy co-efficiencies through improved water systems management, with benefits including improved customer education, automated leak detection, water measurement and verification, optimized system operation, and inherent water and energy conservation. Our findings also suggest that the adoption of these technologies in the water sector has been slow

  12. Efficacy of the ejector flow-meter. A scavenging device for anaesthetic gases

    Energy Technology Data Exchange (ETDEWEB)

    Obel, D.; Jorgensen, S.; Ferguson, A.; Frandsen, K.

    1985-01-01

    Measurements of air concentrations of nitrous oxide and halothane in the breathing zone of the anaesthetist and the operating-room nurse were carried out during inhalation anaesthesia with a Mapleson D system. Gas removal was performed from inside the breathing system at the same rate as that of the fresh gas inflow by means of an ejector flow-meter. The concentrations of nitrous oxide and halothane were maintained below the Danish Threshold Limit Values of 100 and 5 parts per million, respectively, by using this type of scavenging. When these anaesthetics were used simultaneously, the reduced Threshold Limit Values were not exceeded during endotracheal anaesthesia.

  13. Efficacy of the ejector flow-meter. A scavenging device for anaesthetic gases.

    Science.gov (United States)

    Obel, D; Jørgensen, S; Ferguson, A; Frandsen, K

    1985-01-01

    Measurements of air concentrations of nitrous oxide and halothane in the breathing zone of the anaesthetist and the operating-room nurse were carried out during inhalation anaesthesia with a Mapleson D system. Gas removal was performed from inside the breathing system at the same rate as that of the fresh gas inflow by means of an ejector flow-meter. The concentrations of nitrous oxide and halothane were maintained below the Danish Threshold Limit Values of 100 and 5 parts per million, respectively, by using this type of scavenging. When these anaesthetics were used simultaneously, the reduced Threshold Limit Values were not exceeded during endotracheal anaesthesia.

  14. Analysis and Optimation Hydrofoil Supported Catamaran (HYSUCAT Size 25 Meter based on CFD Method

    Directory of Open Access Journals (Sweden)

    Hari Prastowo

    2016-12-01

    Full Text Available In the field of transportation, ship is relatively cheap then others transportation. However, the ship still has constraints on speed and fuel consumption. Therefore, the ship has many variations of shape to achieve optimal condition. For example the body of ships with double hulls (catamaran or three (trimaran, that using foil to make ship can have a smaller resistance to achieve optimal efficiency. The purpose of this research in order to plan the maximum foil shape which can produce high force of buoyance on the catamaran boat (25 meters and also to determine the type of hydrofoil that produces maximum buoyance force using CFD method.

  15. Chapter 9: Metering Cross-Cutting Protocol. The Uniform Methods Project: Methods for Determining Energy-Efficiency Savings for Specific Measures

    Energy Technology Data Exchange (ETDEWEB)

    Mort, Dan [ADM Associates, Inc. Sacramento, CA (United States)

    2017-09-01

    Estimated energy savings are calculated as the difference between the energy use during the baseline period and the energy use during the post installation period of the EEM. This chapter describes the physical properties measured in the process of evaluating EEMs and the specific metering methods for several types of measurements. Skill-level requirements and other operating considerations are discussed, including where, when, and how often measurements should be made. The subsequent section identifies metering equipment types and their respective measurement accuracies. This is followed by sections containing suggestions regarding proper data handling procedures and the categorization and definition of several load types.

  16. Radiation Therapy: Professions in Radiation Therapy

    Science.gov (United States)

    ... Resources Professions Site Index A-Z Professions in Radiation Therapy Radiation Oncologist Therapeutic Medical Physicist Radiation Therapist Dosimetrist Radiation Oncology Nurse Social Worker Dietitian Radiation Oncologist Radiation oncologists are physicians who oversee the ...

  17. Fading Hawking Radiation

    CERN Document Server

    Sakalli, I; Pasaoglu, H

    2012-01-01

    In this study, we explore a particular type Hawking radiation which ends with zero temperature and entropy. The appropriate black holes for this purpose are the linear dilaton black holes. In addition to the black hole choice, a recent formalism in which the Parikh-Wilczek's tunneling formalism amalgamated with quantum corrections to all orders in \\hbar is considered. The adjustment of the coefficients of the quantum corrections plays a crucial role on this particular Hawking radiation. The obtained tunneling rate indicates that the radiation is not pure thermal anymore, and hence correlations of outgoing quanta are capable of carrying away information encoded within them. Finally, we show in detail that when the linear dilaton black hole completely evaporates through such a particular radiation, entropy of the radiation becomes identical with the entropy of the black hole, which corresponds to "no information loss".

  18. Effect of nitrogen and water availability of three soil types on yield, radiation use efficiency and evapotranspiration in field-grown quinoa

    DEFF Research Database (Denmark)

    Razzaghi, Fatemeh; Plauborg, Finn; Jacobsen, Sven-Erik

    2012-01-01

    . This lead to higher interception of photosynthetic active radiation and higher seed yield on sandy clay loam (3.3 Mg ha−1) and sandy loam (3.0 Mg ha−1) than on sand (2.3 Mg ha−1). The soil with higher clay content had also the highest transpiration, crop evapotranspiration and yield due to the higher uptake...

  19. API testing program - calibration of microprocessor based flowmeters for integrated metering systems

    Energy Technology Data Exchange (ETDEWEB)

    Elliot, Kenneth D. [Omni Flow Computers, Inc., Stafford, TX (United States)

    2005-07-01

    Microprocessor based flowmeter technologies for liquids, such as Coriolis mass meters, and Ultrasonic flowmeters hold great promise. These technologies offer many advantages, such as no rotating parts, self-diagnostic checks, which can help anticipate and warn of impending failures before they have a major impact on the measurement. These meters are substantially different though than other primary devices due to their heavy reliance on the accompanying secondary electronics. One method to prove that they are accurate would be proving the flowmeter, using a pipe prover or small volume prover (SVP), but these proving methods are designed to count 'real time' pulses from a turbine or PD meter between a known volume, they are not designed to count 'time delayed' 'manufactured pulses' from a microprocessor. There are limitations of the manufactured pulse train and it affects the ability of the flowmeter to be proved using current proving technology. The author of this paper, a chairman of an American Petroleum Institute working group, investigated how the 'microprocessor generated pulses' produced by these types of flowmeters, interacted with the existing measurement technologies in use today. Several microprocessor based flowmeter technologies have been tested, including; Ultrasonic, Coriolis, and Helical Turbine with pulse multiplying preamplifier. Wherever possible, flowmeters of various sizes, and from several vendors have been tested. A significant amount of data has been collected which sheds light into why these types of flowmeters are sometimes difficult to prove. This paper describes the API testing program, and the methodology behind it. It presents results and findings, and offers specific recommendations that may eventually be incorporated into API documents and/or standards in the future. (author)

  20. 10 CFR 33.15 - Requirements for the issuance of a Type C specific license of broad scope.

    Science.gov (United States)

    2010-01-01

    ... materials, and in the characteristics of ionizing radiation, units of radiation dose and quantities, radiation detection instrumentation, and biological hazards of exposure to radiation appropriate to the type...

  1. Beneficial uses of radiation

    Energy Technology Data Exchange (ETDEWEB)

    Fox, M.R.

    1991-10-01

    An overall decline in technical literacy within the American public has come at a time when technological advances are accelerating in the United States and around the world. This had led to a large communication gulf between the general public and the technologists. Nowhere is this more evident then with the topic of radiation. Regrettably, too few people know about sources of radiation, the pervasiveness, amounts, and variabilities, and do not have a true understanding of the environment in which we live. Nor do many people know that radiation has been used in beneficial ways for decades around the world. While the general public does not know of the scientific applications to which radiation has been deployed, it nevertheless had benefited tremendously from these efforts. Thanks to the well know properties of radiation, scientific ingenuity has found many uses of radiation in chemical and agricultural research, biomedical research, in the diagnoses and treatment of hundreds of types of diseases, in industrial applications, food irradiation, and many others. This paper provides a sample of the types of uses to which radiation has been used to help advance the betterment of humankind.

  2. Radiation hormesis in plant

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Sung; Song, Hi Sup; Lee, Young Keun; Cun, Ki Jung; Shin, In Chul; Lim, Young Taek

    1999-04-01

    This research was performed to investigate the effects of low dose {gamma}-ray radiation on the seed germination and the following physiological responses in vegetable crops. Special attention was focused on whether the resistance of vegetables against the unfavorable conditions of environment such as acid rain or soil types could be enhanced as an aspect of radiation hormesis. Analysis and characterization of antioxidant enzyme from plant culture cells and radiation tolerant of transformed plants from antioxidant enzyme (POD) were accomplished in the plant irradiated with difference dosage of {gamma}-ray.

  3. RADIATION ACOUSTICS

    OpenAIRE

    Lyamshev, L.

    1990-01-01

    Radiation acoustics is a new branch of acoustics. Its' fundamentals are lying in the research of acoustical effects due to the interaction of a radiation with matter. The sound excitation in liquids and solids by modulated or pulsed particle beams (electron, proton, ion beams, γ-radiation and single high-energy elementary particles) and some practical applications are discussed.

  4. In-Vacuum Photogrammetry of a 10-Meter Solar Sail

    Science.gov (United States)

    Meyer, Chris G.; Jones, Thomas W.; Lunsford, Charles B.; Pappa, Richard S.

    2005-01-01

    In July 2004, a 10-meter solar sail structure developed by L Garde, Inc. was tested in vacuum at the NASA Glenn 30-meter Plum Brook Space Power Facility in Sandusky, Ohio. The three main objections of the test were to demonstrate unattended deployment from a stowed configuration, to measure the deployed shape of the sail at both ambient and cryogenic room temperatures, and to measure the deployed structural dynamic characteristics (vibration modes). This paper summarizes the work conducted to fulfill the second test objective. The deployed shape was measured photogrammetrically in vacuum conditions with four 2-megapixel digital video cameras contained in custom made pressurized canisters. The canisters included high-intensity LED ring lights to illuminate a grid of retroreflective targets distributed on the solar sail. The test results closely matched pre-test photogrammetry numerical simulations and compare well with ABAQUS finite-element model predictions.

  5. Digital Metering System of New Generation Smart Substation in China

    Directory of Open Access Journals (Sweden)

    Bai Jingfen

    2016-01-01

    Full Text Available The new generation of smart substation is a summary and improvement of the earlier intelligent substations within the past 5 years. As a part of the substation operation function, the electric energy metering system must adapt to the requirements of the new generation smart substation which is more intelligent, full digitalization, networked and integrated. With the features of digitized, easy information sharing, and hardware shared, the digital measurement system is the inevitable choice for the new generation smart substation. This paper is the first literature to introduce the concept and structure of the digital metering system. The composition and technical characteristics of the new generation Smart Substation measurement system are introduced in detail.

  6. Mobile metering. Enabling cost-efficient smart charging for EVs

    Energy Technology Data Exchange (ETDEWEB)

    Hechtfischer, Knut; Pawlitschek, Frank [ubitricity GmbH, Berlin (Germany); Berg, Andreas [VOLTARIS, Merzig (Germany)

    2012-07-01

    Users of electric vehicles want to and should be mobile with the least possible limitations. A fundamental requirement is an affordable and easy to use charging infrastructure that allows charging of the vehicle, if achievable wherever the EV is parked. ubitricity and VOLTARIS are developing and testing the On-Board Metering system and the underlying business and security concepts for such an ubiquitous charging infrastructure for electric mobility. Further leading partners are supporting the project that is being co-funded by research grants of the German Federal Ministry of Economics and Technology. The basic idea is to install metering and communication technology inside the car to generate the information required for billing processes. (orig.)

  7. Visualization Techniques for Electrical Grid Smart Metering Data: A Survey

    DEFF Research Database (Denmark)

    Stefan, Maria; Lopez, Jose Manuel Guterrez Lopez; Andreasen, Morten Henius

    2017-01-01

    One of the considerable initiatives towards creating a smart society could be the guarantee of a smart, resilient and reliable power grid. As an attempt to improve the electricity supply service, it would be meaningful for the distributed system operators (DSOs) to be able to monitor the current...... constitute the baseline for bringing improvements to the power grid. This paper presents an approach to build an efficient visualization system so that the extracted smart meters information can be used in a meaningful manner. An overview of the use cases related to the visualization features is first...... status of the grid. The prediction of future possible critical situations would then be feasible using the available information, whereas, based on historical data, further grid expansion and reinforcement may be planned. A proper presentation and visualization of the near-real time metering data may...

  8. Development of on-board fuel metering and sensing system

    Science.gov (United States)

    Hemanth, Y.; Manikanta, B. S. S.; Thangaraja, J.; Bharanidaran, R.

    2017-11-01

    Usage of biodiesel fuels and their blends with diesel fuel has a potential to reduce the tailpipe emissions and reduce the dependence on crude oil imports. Further, biodiesel fuels exhibit favourable greenhouse gas emission and energy balance characteristics. While fossil fuel technology is well established, the technological implications of biofuels particularly biodiesel is not clearly laid out. Hence, the objective is to provide an on-board metering control in selecting the different proportions of diesel and bio-diesel blends. An on-board fuel metering system is being developed using PID controller, stepper motors and a capacitance sensor. The accuracy was tested with the blends of propanol-1, diesel and are found to be within 1.3% error. The developed unit was tested in a twin cylinder diesel engine with biodiesel blended diesel fuel. There was a marginal increase (5%) in nitric oxide and 14% increase in smoke emission with 10% biodiesel blended diesel at part load conditions.

  9. Distribution system intelligent state estimation through minimal meter placement

    Energy Technology Data Exchange (ETDEWEB)

    Ramesh, L. [Jadavpur Univ., Kolkata (India). Dept. of Electrical Engineering; Chowdhury, S.; Chowdhury, S.P.; Gaunt, C.T. [Cape Town Univ. (South Africa)

    2009-03-11

    A method of accurately estimating electrical parameters for distribution automation systems in power distribution networks was presented. A particle swarm optimization (PSO) algorithm was used to identify meter locations as well as to monitor and estimate parameters in the distribution system. The determined locations were then used to monitor and estimate parameters using a SCADA system arrangement. Parameter values were estimated using a hybrid artificial neural network (ANN) based estimation technique where pseudo-measurements were injected at un-metered buses. An Institute of Electrical and Electronic Engineers (IEEE) 13-node system with a distribution system used by the Tamil Nadu Electrical Board in India was used to verify the method. Results of the study showed that the proposed algorithm can be used to accurately estimate the electrical parameters of distribution automation systems. The method will be used to determine the position of future switch position and transformer locations. 22 refs., 1 tab., 6 figs.

  10. Analysis of FDML lasers with meter range coherence

    Science.gov (United States)

    Pfeiffer, Tom; Draxinger, Wolfgang; Wieser, Wolfgang; Klein, Thomas; Petermann, Markus; Huber, Robert

    2017-02-01

    FDML lasers provide sweep rates in the MHz range at wide optical bandwidths, making them ideal sources for high speed OCT. Recently, at lower speed, ultralong-range swept-source OCT has been demonstrated using a tunable vertical cavity surface emitting laser (VCSEL) and also using a Vernier-tunable laser. These sources provide relatively high sweep rates and meter range coherence lengths. In order to achieve similar coherence, we developed an extremely well dispersion compensated Fourier Domain Mode Locked (FDML) laser, running at 3.2 MHz sweep rate and 120 nm spectral bandwidth. We demonstrate that this laser offers meter range coherence and enables volumetric long range OCT of moving objects.

  11. Security Challenges in Smart-Grid Metering and Control Systems

    OpenAIRE

    Xinxin Fan; Guang Gong

    2013-01-01

    The smart grid is a next-generation power system that is increasingly attracting the attention of government, industry, and academia. It is an upgraded electricity network that depends on two-way digital communications between supplier and consumer that in turn give support to intelligent metering and monitoring systems. Considering that energy utilities play an increasingly important role in our daily life, smart-grid technology introduces new security challenges that must be addressed. Depl...

  12. Data acquisition and meter unit based in wifi communication protocol

    Directory of Open Access Journals (Sweden)

    Gerardo Cázarez Ayala

    2012-05-01

    Full Text Available Without doubt, the competitive fast rhythm of the industries is one of the main causes helped bring to the accelerated growth of the electronic technology and the communication. The need to develop new products with a best quality, cheaper and faster as assure and increase the quality of the products in the international markets, requires of new technologies to the metering, monitoring and control of their production processes, of which finality is to improve the processes to guaranteed their products in the market in the less time possible, the best quality and low cost for the final consumer. This work is based in the design and implementation of a Wireless Data Acquisition Unit based in WiFi protocol, which is oriented to meter, monitoring and the control of processes in the industry, commercial and the home automation applications, using one of the wirelessprotocols with the biggest acceptance in the market, with the main objective of to take advantage of the installed physical infrastructure in the place of the application, like industry, company or house. The Unit is based in the RN-131G, a Roving Network company module, which is able to work in stand-alone mode with ultralow power consummation and supporting the IEEE 802.11b/g protocols, in which is possible to achieve transfer rates of up to 11 Mbps and 54 Mbps in /b & /g specifications respectively. Whit this unit is possible to meter up to 5 analogs signals with 14 bits precision and has include a temperature and relative humidity sensors. This unit can meter two digital signals and act mean two digitals outputs, and gas include an USB port for communication and programming tasks.

  13. Experimental and numerical investigation of thermal flow meter

    Directory of Open Access Journals (Sweden)

    Cebula Artur

    2015-09-01

    Full Text Available The paper presents analytical and numerical model calculation results of the temperature distribution along the thermal flow meter. Results show a very good conformity between numerical and analytical model. Apart from the calculation results the experimental investigations are presented. The author performed the test where a temperature of duct wall surface was measured. The relation between mass flow rate in terms of the duct surface temperature difference was developed.

  14. INFLUENCE OF FUNCTIONAL ABILITY IN RUNNING 400 AND 800 METERS

    OpenAIRE

    Abdulla Elezi; Hasim Rushiti; Afrim Koca

    2013-01-01

    Goal of the research was to assess on the grounds of data collected that were used to assess the functional ability of the cardio-respiratory system and the results of running to determine the relation of these sum of variables. Basic statistical indicators of the physiological variables and results of running were calculated. For determining the relation, the regression analysis was used in the manifested space. Criterion variable (running for 100 meters) did not demonstrate statistically si...

  15. Strategies for Power Line Communications Smart Metering Network Deployment

    OpenAIRE

    Alberto Sendin; Ivan Peña; Pablo Angueira

    2014-01-01

    Smart Grids are becoming a reality all over the world. Nowadays, the research efforts for the introduction and deployment of these grids are mainly focused on the development of the field of Smart Metering. This emerging application requires the use of technologies to access the significant number of points of supply (PoS) existing in the grid, covering the Low Voltage (LV) segment with the lowest possible costs. Power Line Communications (PLC) have been extensively used in electricity grids ...

  16. 40 CFR 1065.640 - Flow meter calibration calculations.

    Science.gov (United States)

    2010-07-01

    ... temperature of the flow rate. R = molar gas constant. M mix = molar mass of the flow rate. Example 1: V stdref... POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Calculations and Data Requirements § 1065.640 Flow meter....314472 J/(mol·K) ER08OC08.101 n ref = 19.619 mol/s Example 2: m ref = 17.2683 kg/min = 287.805 g/s M mix...

  17. Accidental Cutaneous Burns Secondary to Salbutamol Metered Dose Inhaler

    Directory of Open Access Journals (Sweden)

    Ashutosh Kale

    2010-01-01

    Full Text Available We report a case of accidental cutaneous burns caused by salbutamol metered dose inhaler. A 9-year-old boy underwent dental extraction at a children's hospital and was incidentally noted to have burn injuries on dorsum of both hands. On questioning, the boy revealed that a few days ago his 14-year-old brother, who is an asthmatic, playfully sprayed his salbutamol metered dose inhaler on the back of both his hands with the inhaler's mouth piece being in direct contact with the patient's skin. On examination, there was a rectangular area of erythema with superficial peeling on the dorsum of both hands, the dimensions of which exactly matched those of the inhaler's mouthpiece. It is possible that the injury could have been a chemical burn from the pharmaceutical/preservative/propellant aerosol or due to the physical effect of severe cooling of the skin or mechanical abrasive effect of the aerosol blasts or a combination of some or all the above mechanisms. This case highlights the importance of informing children and parents of the potentially hazardous consequences of misusing a metered dose inhaler.

  18. Stress-meter alignment in French vocal music.

    Science.gov (United States)

    Temperley, Nicholas; Temperley, David

    2013-07-01

    Previous research has shown disagreement regarding the nature of stress in French. Some have maintained that French has lexical stress on the final syllable of each word; others have argued that French has no lexical stress, only phrasal stress. A possible source of evidence on this issue is vocal music. In languages with lexical stress, such as English, it is well known that stressed syllables tend to occur at "strong" positions in the musical meter (some evidence will be presented supporting this view). A corpus analysis was performed to investigate the degree of stress-meter alignment in French songs. The analysis showed that (excluding syllables at the ends of lines) the final syllables of polysyllabic words tend to occur at stronger metrical positions than non-final syllables of those words; it also showed that monosyllabic content words tend to occur at stronger positions than monosyllabic function words. While conflicts between stress and meter are much more common in French than in English vocal music, these results suggest that French poets and composers recognized distinctions of stress between syllables of polysyllabic words and between monosyllabic content and function words.

  19. Comprehensive Flow Meter for All Materials. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-11-15

    The electromagnetic flowmeter is obstructionless and insensitive to the metered stuff's constitutive properties. For low zero-point drift, EM flowmeters employ a low frequency alternating induction, usually with square waveshape. With conventional signal conditioning, high frequency induction leads to excessive zero-point drift for the instrument. The conventional instrument is usable with electrically conductive fluids, where there is no triboelectric noise. Nonconductive fluids have substantial triboelectric noise, with spectral density experimentally measured to be f{sup {minus}2.6}. Here we use an electromagnet and signal conditioner that allows high frequency induction, where the noise is low, but eliminates the heretofore excessive drift--such that the EM flowmeter can be used to meter any stuff, whether conductive or insulating, that can be pumped, blown or extruded through a pipe. Designs and test hardware are shown. An injury occurred, with slow recovery: the principal investigator could not do all the flow test stand work desired. As an option, the flow testing has been simulated on a computer. Using characteristics of transformer oil as the metered fluid, the new signal conditioner has produced: (1) signal/noise/drift behavior experienced in prior published work, and (2) signal--without noise and drift--with performance of today's commercial EM flowmeters.

  20. Accidental cutaneous burns secondary to salbutamol metered dose inhaler.

    Science.gov (United States)

    Kale, Ashutosh; Shackley, Fiona

    2010-01-01

    We report a case of accidental cutaneous burns caused by salbutamol metered dose inhaler. A 9-year-old boy underwent dental extraction at a children's hospital and was incidentally noted to have burn injuries on dorsum of both hands. On questioning, the boy revealed that a few days ago his 14-year-old brother, who is an asthmatic, playfully sprayed his salbutamol metered dose inhaler on the back of both his hands with the inhaler's mouth piece being in direct contact with the patient's skin. On examination, there was a rectangular area of erythema with superficial peeling on the dorsum of both hands, the dimensions of which exactly matched those of the inhaler's mouthpiece. It is possible that the injury could have been a chemical burn from the pharmaceutical/preservative/propellant aerosol or due to the physical effect of severe cooling of the skin or mechanical abrasive effect of the aerosol blasts or a combination of some or all the above mechanisms. This case highlights the importance of informing children and parents of the potentially hazardous consequences of misusing a metered dose inhaler.