  1. Exemption of the use of radiation from the safety licence and reporting obligation

    International Nuclear Information System (INIS)

    1999-07-01

    The primary means of controlling the use of radiation is the safety licence procedure. The safety licence, and the granting of the licence, are regulated in the section 16 of the Finnish Radiation Act (592/1991). In section 17 of the act, certain practices are exempted from the safety licence. In addition to these practices, the Radiation and Nuclear Safety (STUK) may (on the basis of the same legal clause) exempt other types of radiation use from the safety licence, if it is possible to ascertain with sufficient reliability that the use of the radiation will not cause damage or danger to health. This guide presents the conditions applying to exemption from the safety licence for the use of radiation and reporting obligation, and also the exemption values for radioactive substances which, if exceeded, will entail the application of the safety licence and notification procedure for the use of radiation in question. The guide also presents exemptions in the use of exemption values, and requirements associated with the exemption of radiation appliances. However, the guide does not apply to the use of nuclear energy

  2. Exemption of the use of radiation from the safety licence and reporting obligation

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-07-01

    The primary means of controlling the use of radiation is the safety licence procedure. The safety licence, and the granting of the licence, are regulated in the section 16 of the Finnish Radiation Act (592/1991). In section 17 of the act, certain practices are exempted from the safety licence. In addition to these practices, the Radiation and Nuclear Safety (STUK) may (on the basis of the same legal clause) exempt other types of radiation use from the safety licence, if it is possible to ascertain with sufficient reliability that the use of the radiation will not cause damage or danger to health. This guide presents the conditions applying to exemption from the safety licence for the use of radiation and reporting obligation, and also the exemption values for radioactive substances which, if exceeded, will entail the application of the safety licence and notification procedure for the use of radiation in question. The guide also presents exemptions in the use of exemption values, and requirements associated with the exemption of radiation appliances. However, the guide does not apply to the use of nuclear energy.

  3. Results of environmental radiation monitoring and meteorology measurements (material prepared for obtaining the licence for RA reactor experimental operation)

    International Nuclear Information System (INIS)

    1980-10-01

    According to the demands for obtaining the licence for restarting the Ra reactor and the experimental operation this document includes the radiation monitoring measured data in the working space and environment of the RA reactor, i.e. Boris Kidric Institute. The meteorology measured data are included as well. All the measurements are performed according to the radiation protection program applied actually from the first reactor start-up at the end of 1959 [sr

  4. Preparation of an annual report for a consolidated radioisotope licence

    International Nuclear Information System (INIS)

    1985-01-01

    A consolidated radioisotope licence is a single license issued by the Atomic Energy Control Board (AECB) to an institution having many users of radioactive materials. The licence is issued when the institution has fulfilled the requirements set by the AECB and has implemented policies and procedures which will ensure the maintenance of an effective radiation safety program. The consolidated licence is retained only if the results of AECB inspections are satisfactory -- or remedial action is taken promptly -- and if the institution reports regularly about the status of its radiation safety program. One aspect of this reporting procedure is an annual report. This guide describes the information that the AECB requires in the annual report. The guide applies primarily to universities and research institutions where a wide variety of radioisotope uses take place. The guide does not affect most other institutions or facilities, either because the nature and extent of their operations with radioactive materials do not lend themselves to consolidated licensing or because they are not licensed by the Radioisotopes and Transportation Division. (For example, this guide does not apply to reactors, to accelerators, or to waste management or uranium mining or refining facilities.) The information in the annual report should be specific to the consolidated radioisotope licence. Incidents, staff exposures, and waste associated with accelerators, research reactors, and waste management facilities should be excluded from this report unless they affected activities under the consolidated licence

  5. Complex licences: a decade of experience with internal inspections

    International Nuclear Information System (INIS)

    Boersma, Hielke Freerk; Bunskoeke, Erik J.

    2008-01-01

    Full text: In 2008 the University of Groningen has ten years of experience with the system of complex broad licences. This system was introduced on a larger scale in the Netherlands in the last decade of the twentieth century. Its main characteristics are an internal radiation protection organization and a system of internal permits or licences for all applications of ionizing radiation along with periodical inspections. Since 1998/9 we yearly conduct inspections of all users of ionizing radiation within the University of Groningen. In our presentation we will discuss the general scheme for these inspections as well as the development of its results over the past decade. Following a period of habituation the last few years show a adequate and continuous level of radiation protection. It is also concluded that continuation of the inspection projects is a prerequisite to preserve this situation. Combined with the inspection project of 2007 an informal study of the 'customer'-satisfaction with respect to various aspects of the radiation protection organization was performed. Our data were collected using a questionnaire filled out by local radiation safety officers. In this contribution detailed results of this investigation will be presented. Preliminary results show that the overall appreciation of the radiation protection organization is qualified as 'good'. (author)

  6. Royal Order of 27 July 1966 relating to the reciprocal recognition of licences for the import, transport, transit, and distribution of radioactive substances between the countries of the Benelux Economic Union

    International Nuclear Information System (INIS)

    1966-01-01

    This Royal Order made taking into account the 1958 Act on protection of the population against the hazards of ionizing radiations, the 1963 Royal Order embodying the general regulations on protection of the population and workers against the hazards of ionizing radiations and the 1966 recommendation of the Committee of Ministers of the Benelux Economic Union lays down that, notwithstanding Section 38 and 57 of the 1963 Royal Order, licences for the import, transport and transit of radioactive substances or devices containing them which are issued by the competent authorities of the Netherlands or Luxembourg are valid in Belgium. Also, a Belgia distributor of such substances or devices containing them must ensure that a consignee residing in either of these countries holds the licences required by his national law. (NEA) [fr

  7. Radiation emitting devices regulations

    International Nuclear Information System (INIS)

    1970-01-01

    The Radiation Emitting Devices Regulations are the regulations referred to in the Radiation Emitting Devices Act and relate to the operation of devices. They include standards of design and construction, standards of functioning, warning symbol specifications in addition to information relating to the seizure and detention of machines failing to comply with the regulations. The radiation emitting devices consist of the following: television receivers, extra-oral dental x-ray equipment, microwave ovens, baggage inspection x-ray devices, demonstration--type gas discharge devices, photofluorographic x-ray equipment, laser scanners, demonstration lasers, low energy electron microscopes, high intensity mercury vapour discharge lamps, sunlamps, diagnostic x-ray equipment, ultrasound therapy devices, x-ray diffraction equipment, cabinet x-ray equipment and therapeutic x-ray equipment

  8. Valuing commercial radio licences

    NARCIS (Netherlands)

    Kerste, M.; Poort, J.; van Eijk, N.

    2015-01-01

    Within the EU regulatory framework, licensees for commercial radio broadcasting may be charged a fee to ensure optimal allocation of scarce resources but not to maximize public revenues. While radio licence renewal occurs in many EU countries, an objective, model-based approach for setting licence

  9. Radiation emitting devices act

    International Nuclear Information System (INIS)

    1970-01-01

    This Act, entitled the Radiation Emitting Devices Act, is concerned with the sale and importation of radiation emitting devices. Laws relating to the sale, lease or import, labelling, advertising, packaging, safety standards and inspection of these devices are listed as well as penalties for any person who is convicted of breaking these laws

  10. Foreign driving licences in Switzerland

    CERN Multimedia

    DG Unit

    2009-01-01

    1. Persons residing in Switzerland 1.1 Holders of a B, C, D, E or P-type "carte de légitimation" For holders of a B, C, D, E or P-type "carte de légitimation" issued by the Swiss Federal Department for Foreign Affairs (DFAE), current non-Swiss national driving licences are valid in Switzerland. If they so wish, holders of such driving licences may apply to the relevant road licensing authority in the canton where they live (Service des Automobiles et de la Navigation; for Geneva call + 41 22 388 30 30, website http://www.geneve.ch/san; for Vaud call + 41 21 316 82 10, website http://www.san.vd.ch/index.html) to exchange their driving licence for an equivalent Swiss licence (they must pass a test if they are not citizens of countries with which Switzerland has concluded an agreement on this matter, e.g. Member States of the European Union, the United States and Japan). However, such an exchange is not possible if the driving licence was issued in a foreign country during a...

  11. FOREIGN DRIVING LICENCES IN SWITZERLAND

    CERN Document Server

    Relatiopns with the Host States Service

    2001-01-01

    1. PERSONS RESIDING IN SWITZERLAND 1.1 Holders of a B, C, D or E-type carte de légitimation For holders of B, C, D or E-type cartes de légitimation issued by the Swiss Federal Department for Foreign Affairs (Département fédéral suisse des Affaires étrangères, hereinafter called DFAE), current non-Swiss national driving licences are valid in Switzerland. Should they so wish, holders of such driving licences may apply to the relevant roads authority in the canton where they live (Service des Automobiles et de la Navigation ; for Geneva call 022/343 02 00, website: http://www.geneve.ch/san/welcome.html, for Vaud call 021/316 82 10, website: http://www.dse.vd.ch/auto/index.html) in order to exchange their driving licence for an equivalent Swiss licence. However, exchanges are not permitted if the driving licence was issued in a foreign country during a stay there of less than six months' duration while the person concerned was officially...

  12. Radiation effects in optoelectronic devices

    International Nuclear Information System (INIS)

    Barnes, C.E.

    1977-03-01

    A summary is given of studies on radiation effects in light-emitting diodes, laser diodes, detectors, optical isolators and optical fibers. It is shown that the study of radiation damage in these devices can provide valuable information concerning the nature of the devices themselves, as well as methods of hardening these devices for applications in radiation environments

  13. Designing a licence plate for memorability

    NARCIS (Netherlands)

    Schraagen, J.M.C.; Dongen, C.J.G. van

    2005-01-01

    Good memorability of licence plates is important in those cases where licence plates are viewed for a brief period of time and the information is essential for police investigations. The purpose of the current study was to design a new Dutch licence plate that could be remembered well. A memory

  14. Licence prolongations of US nuclear power plants; Les prolongations de licence des centrales nucleaires americaines

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-04-01

    Licences of US nuclear reactors were initially attributed for a 40 years duration. However, the vast majority of the reactors can benefit of a licence prolongation for a period of 20 years maximum. This article recalls first the procedure to follow for the licence prolongation demands (safety analysis, components aging, environmental impact statement), and then it makes a status of the accepted prolongations, of the demands under examination, and of the demands that should be presented in the next 5 years. (J.S.)

  15. What Gives You a Social Licence? An Exploration of the Social Licence to Operate in the Australian Mining Industry

    Directory of Open Access Journals (Sweden)

    Sara Bice

    2014-01-01

    Full Text Available This article analyses the ways in which major, multinational mining companies operating within Australia understand sustainable development and articulate their “social licence to operate”. The article contributes a novel perspective to ongoing discussions about the social licence by exploring the ways in which leading Australian mining companies define and assert their social licences through sustainable development discourse. A content and discourse analysis of 18 sustainability reports across a four year period, supplemented by qualitative interview data, draws out these issues. While most companies use these reports to confirm beliefs in the necessity of a social licence, the ways in which the licence is specifically defined and maintained are not generally made explicit. Additionally, key theoretical criteria required for a social licence, such as free, prior and informed consent, appear to be overlooked. In conclusion, the article suggests ways in which criteria for a social licence within the mining industry could be defined more clearly and raises consequent questions to shape future research.

  16. FOREIGN DRIVING LICENCES IN FRANCE

    CERN Multimedia

    Service des relations avec les Pays Hôtes

    2000-01-01

    1. PERSONS RESIDING IN FRANCE1.1 National driving licences from countries belonging to the EEAa) ValidityCurrent national driving licences issued by a country belonging to the European Economic Area (here inafter called EEA) are, in principle, valid in France. N.B. : The countries belonging to the EEA are Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Liechtenstein, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden and the United Kingdom.b)\tRegistrationTo ensure that all the conditions of validity in France have been met, holders of driving licences issued by a country belonging to the EEA, who reside in France (i.e. hold a residence permit issued by a Préfecture, or a carte spéciale issued by the French Ministry of Foreign Affairs, which is equivalent to a residence permit), can have their licences registered with the Préfecture of the department where they live (for Ain, call 04 74 32 30 00, for Haute Savoie call 04 50 33 ...

  17. Radiation analysis devices, radiation analysis methods, and articles of manufacture

    Science.gov (United States)

    Roybal, Lyle Gene

    2010-06-08

    Radiation analysis devices include circuitry configured to determine respective radiation count data for a plurality of sections of an area of interest and combine the radiation count data of individual of sections to determine whether a selected radioactive material is present in the area of interest. An amount of the radiation count data for an individual section is insufficient to determine whether the selected radioactive material is present in the individual section. An article of manufacture includes media comprising programming configured to cause processing circuitry to perform processing comprising determining one or more correction factors based on a calibration of a radiation analysis device, measuring radiation received by the radiation analysis device using the one or more correction factors, and presenting information relating to an amount of radiation measured by the radiation analysis device having one of a plurality of specified radiation energy levels of a range of interest.

  18. Foreign driving licences in France

    CERN Multimedia

    HR Department

    2009-01-01

    The following information is subject to possible amendments decided by the competent French authorities. Those wishing to undertake the necessary steps with the prefectural services of the Departments of the Ain and Haute-Savoie may obtain information by calling the following numbers: + 33 4 74 32 30 65 for the Ain and + 33 4 50 33 60 00 for Haute-Savoie. 1. PERSONS RESIDING IN FRANCE 1.1 Driving licences issued by a State belonging to the EU or the EEA a) Recognition on French territory All currently valid driving licences issued by States belonging to the European Union (EU) or to the European Economic Area (EEA) are generally valid for driving on French territory. However, if the licence was originally obtained in exchange for a licence issued by a State not belonging to the EU or to the EEA and with which France has not concluded a reciprocity agreement, it will be recognised for a maximum of one year following the date of establishment of normal residence in France ...

  19. FOREIGN DRIVING LICENCES IN FRANCE

    CERN Multimedia

    DSU Unit

    2008-01-01

    The following information is provided subject to possible amendments decided by the competent French authorities. Those wishing to undertake the necessary steps with the prefectural services of the Departments of Ain and Haute-Savoie may obtain information by calling the following numbers: + 33 474 32 30 65 for Ain and + 33 450 33 60 00 for Haute-Savoie. 1. PEOPLE RESIDING IN FRANCE 1.1 Driving licences issued by a state belonging to the EU or the EEA a) Recognition on French territory All currently valid driving licences issued by States belonging to the European Union (EU) or to the European Economic Area (EEA) are generally valid for driving on French territory. However, if the licence was originally obtained in exchange for a licence issued by a State not belonging to the EU or to the EEA with which France has not concluded a reciprocity agreement, it is recognised only up to one year following the date of establishment of normal residence in France (date of the first special residence permit issu...

  20. Foreign driving licences in Switzerland

    CERN Multimedia

    2009-01-01

    1. Persons residing in Switzerland 1.1 Holders of a B, C, D, E or P-type "carte de légitimation" For holders of a B, C, D, E or P-type "carte de légitimation" issued by the Swiss Federal Department for Foreign Affairs (DFAE), current non-Swiss national driving licences are valid in Switzerland. (see the official news about the new "Carte de légitimation P") If they so wish, holders of such driving licences may apply to the relevant road licensing authority in the canton where they live (Service des Automobiles et de la Navigation; for Geneva call + 41 22 388 30 30, website http://www.geneve.ch/san; for Vaud call + 41 21 316 82 10, website http://www.san.vd.ch/index.html) to exchange their driving licence for an equivalent Swiss licence (they must pass a test if they are not citizens of countries with which Switzerland has concluded an agreement on this matter, e.g. Member States of the European Union, the United States and Japan). However, such an exchange is not possible...

  1. Community engagement and social licence to operate

    NARCIS (Netherlands)

    Dare, Melanie (Lain); Schirmer, Jacki; Vanclay, Frank

    2014-01-01

    Achieving ‘a social licence to operate’ is important for organisations with long time horizons, high exposure to global markets and with a wide range of interested stakeholders. Community engagement is critical to achieve a social licence to operate, but its capacity to influence social licence is

  2. Licence template for mobile handling and storage of radioactive substances for the nondestructive testing of materials

    International Nuclear Information System (INIS)

    Lange, A.; Schumann, J.; Huhn, W.

    2016-01-01

    The Technical Committee ''Radiation Protection'' (Fachausschuss ''Strahlenschutz'') and the Laender Committee ''X-ray ordinance'' (Laenderausschuss ''Roentgenverordnung'') have appointed a working group for the formulation of licence templates for the nationwide use of X-ray equipment or handling of radioactive substances. To date, the following licence templates have been adopted: - Mobile operation of X-ray equipment under technical radiography to the coarse structural analysis in material testing; - Mobile operation of a handheld X-ray fluorescence system; - Mobile operation of a flash X-ray system; - Operation of an X-ray system for teleradiology The licence template ''Mobile handling and storage of radioactive substances for the nondestructive testing of materials'' is scheduled for publication. The licence template ''Practices in external facilities and installations'' is currently being revised. The licence template ''Mobile handling and storage of radioactive substances for the nondestructive testing of materials'' is used as an example to demonstrate the legal framework and the results of the working group.

  3. Radiation protection Ordinance

    International Nuclear Information System (INIS)

    1976-06-01

    This Ordinance lays down the licensing system for activities in Switzerland involving possible exposure to radiation, with the exception of nuclear installations, fuels and radioactive waste which, under the 1959 Atomic Energy Act, are subject to licensing. The Ordinance applies to the production, handling, use, storage, transport, disposal, import and export of radioactive substances and devices and articles containing them; and generally to any activity involving hazards caused by ionizing radiation. The Federal Public Health Office is the competent authority for granting licences. Provision is also made for the administrative conditions to be complied with for obtaining such licences as well as for technical measures required when engaged in work covered by the Ordinance. This consolidated version of the Ordinance contains all the successive amendments up to 26 September 1988. (NEA) [fr

  4. Ordinance of 30 June 1976 on radiation protection

    International Nuclear Information System (INIS)

    1976-01-01

    This Ordinance on radiation protection lays down the licensing system for activities in Switzerland involving possible exposure to radiation, with the exception of nuclear installations, fuels and radioactive waste which, under the 1959 Atomic Energy Act, are subject to licensing. The Ordinance applies to the production, handling, use, storage, transport, disposal, import and export of radioactive substances and devices and articles containing them; and generally to any activity involving hazards caused by ionizing radiation. The Federal Public Health Service is the competent authority for granting licences. Provision is also made for the administrative conditions to be complied with for obtaining such licences as well as for technical measures required when engaged in work covered by the Ordinance. (NEA) [fr

  5. [Driver's licence: responsibility, ethics and deontology].

    Science.gov (United States)

    Lucas, P

    1999-09-01

    The new law enacted on march 23rd 1998 regarding driving-licence, which became effective on october 1st 1998, modifies the method for obtaining the different types of driving-licences. Its 6th annex enumerates a list of physical impairments and pathologies implying the denial, the limitation or the withdrawal of the driving-licence; it determines if a medical advice, and if the case which kind of medical advice, is required. This leads to new situations, for which no jurisprudence has been established to date, where not only the responsibility of the licence's applicant but also that of the examining physician could be suspected. The physicians are also confronted to ethical an deontological problems on which the medical authorities have not always given an opinion. This paper examines them in order to give some bases for reflexion and discussion.

  6. Radiation effects in optoelectronic devices

    International Nuclear Information System (INIS)

    Barnes, C.E.; Wiczer, J.J.

    1984-05-01

    Purpose of this report is to provide not only a summary of radiation damage studies at Sandia National Laboratories, but also of those in the literature on the components of optoelectronic systems: light emitting diodes (LEDs), laser diodes, photodetectors, optical fibers, and optical isolators. This review of radiation damage in optoelectronic components is structured according to device type. In each section, a brief discussion of those device properties relevant to radiation effects is given

  7. A licence renewal approach for the NRU research reactor

    International Nuclear Information System (INIS)

    Natalizio, A.; Gumley, P.

    1991-01-01

    Licence Renewal is not only a subject that is being addressed for power reactors, but it is one of immediate interest for a number of research facilities, world-wide. In Canada, research reactors and power reactors are issued an operating licence for a limited term (typically two years), hence, licence renewal is done on a regular basis. Therefore, licence renewal in the Canadian context is different than in the context of this topical meeting. The NRU research reactor facility is being assessed for a licence renewal beyond its original design life. This paper describes the licence renewal approach, the assessments being performed to establish the condition of the facility, and the Safety Assessment Basis which defines the requirements for licence renewal. The current status of the assessments is also described. (author)

  8. Radioisotope licence application: Fixed nuclear gauges

    International Nuclear Information System (INIS)

    1995-09-01

    This guide will assist you in completing and filing an application for a new licence or licence renewal for fixed nuclear gauges in accordance with the Atomic Energy Control Regulations and radioisotope licensing policies. It also provides some of the background information that you will require in order to safely use radioactive materials

  9. Licence prolongations of US nuclear power plants

    International Nuclear Information System (INIS)

    2004-04-01

    Licences of US nuclear reactors were initially attributed for a 40 years duration. However, the vast majority of the reactors can benefit of a licence prolongation for a period of 20 years maximum. This article recalls first the procedure to follow for the licence prolongation demands (safety analysis, components aging, environmental impact statement), and then it makes a status of the accepted prolongations, of the demands under examination, and of the demands that should be presented in the next 5 years. (J.S.)

  10. Radiation area monitor device and method

    Science.gov (United States)

    Vencelj, Matjaz; Stowe, Ashley C.; Petrovic, Toni; Morrell, Jonathan S.; Kosicek, Andrej

    2018-01-30

    A radiation area monitor device/method, utilizing: a radiation sensor; a rotating radiation shield disposed about the radiation sensor, wherein the rotating radiation shield defines one or more ports that are transparent to radiation; and a processor operable for analyzing and storing a radiation fingerprint acquired by the radiation sensor as the rotating radiation shield is rotated about the radiation sensor. Optionally, the radiation sensor includes a gamma and/or neutron radiation sensor. The device/method selectively operates in: a first supervised mode during which a baseline radiation fingerprint is acquired by the radiation sensor as the rotating radiation shield is rotated about the radiation sensor; and a second unsupervised mode during which a subsequent radiation fingerprint is acquired by the radiation sensor as the rotating radiation shield is rotated about the radiation sensor, wherein the subsequent radiation fingerprint is compared to the baseline radiation fingerprint and, if a predetermined difference threshold is exceeded, an alert is issued.

  11. A valid licence

    NARCIS (Netherlands)

    Spoolder, H.A.M.; Ingenbleek, P.T.M.

    2010-01-01

    A valid licence Tuesday, April 20, 2010 Dr Hans Spoolder and Dr Paul Ingenbleek, of Wageningen University and Research Centres, share their thoughts on improving farm animal welfare in Europe At the presentation of the European Strategy 2020 on 3rd March, President Barroso emphasised the need for

  12. A guide for approval of x-ray fluorescence analysis devices

    International Nuclear Information System (INIS)

    1990-01-01

    This guide has been written to assist manufacturers, distributors and users of x-ray fluorescence analysis devices in the preparation of a submission to the Atomic Energy Control Board (AECB) in support of a request for approval of an x-ray fluorescence analysis device. Prior to the issuance of a Radioisotope licence authorizing the use or possession of an x-ray fluorescence analysis device in Canada, the design and construction of the device must be approved by the AECB. The AECB assessment is limited to the radiation safety aspects of use and packaging for transportation

  13. Radiation flux measuring device

    International Nuclear Information System (INIS)

    Corte, E.; Maitra, P.

    1977-01-01

    A radiation flux measuring device is described which employs a differential pair of transistors, the output of which is maintained constant, connected to a radiation detector. Means connected to the differential pair produce a signal representing the log of the a-c component of the radiation detector, thereby providing a signal representing the true root mean square logarithmic output. 3 claims, 2 figures

  14. Liquor licences issued to Australian schools.

    Science.gov (United States)

    Ward, Bernadette M; Kippen, Rebecca; Munro, Geoffrey; Buykx, Penny; McBride, Nyanda; Wiggers, John; Clark, Madeline

    2017-08-01

    Children's positive socialisation to alcohol is associated with early initiation of drinking and alcohol-related harm in adult life. Internationally, there have been reports of adults' alcohol consumption at school events in the presence of children. The aim of this research was to identify the conditions under which Australian schools are required to apply for a liquor licence and the associated prevalence of liquor licences for these events where children were likely to be present. A document review was conducted to examine temporary liquor licensing legislation. Quantitative analysis was used to examine relevant licensing data. Coding criteria was developed to determine school type, student year levels and the likely presence of children. Four jurisdictions provided data on 1817 relevant licences. The average annual licences/100 schools was highest amongst Independent schools followed by Catholic and public (government) schools. The rates were highest in Queensland and Victoria where children were present at 61% and 32% of events respectively. While there are legislative differences across jurisdictions, the prevalence of adults' alcohol use at school events in the presence of children may reflect the various education department policies and principals' and school communities' beliefs and attitudes. Licences are not required for all events where liquor is consumed so the prevalence of adults' use of alcohol at school events is likely to be higher than our analyses imply. Such practices may undermine teaching about alcohol use in the school curriculum and health promotion efforts to develop alcohol-free events when children are present.

  15. SOR/72-43 Radiation Emitting Devices Regulations

    International Nuclear Information System (INIS)

    1972-01-01

    These Regulations of 10 February 1972, supplemented by SOR/77-895, lay down the classes of radiation emitting devices for the purposes of the Radiation Emitting Devices Act. They lay down their standards of design and construction and warning sign specifications and provide for the procedure to be followed by inspectors of such devices. The devices include inter alia extra-oral dental x-ray equipment, baggage inspection x-ray devices, laser scanners, television receivers. (NEA)

  16. Silicon solid state devices and radiation detection

    CERN Document Server

    Leroy, Claude

    2012-01-01

    This book addresses the fundamental principles of interaction between radiation and matter, the principles of working and the operation of particle detectors based on silicon solid state devices. It covers a broad scope with respect to the fields of application of radiation detectors based on silicon solid state devices from low to high energy physics experiments including in outer space and in the medical environment. This book covers stateof- the-art detection techniques in the use of radiation detectors based on silicon solid state devices and their readout electronics, including the latest developments on pixelated silicon radiation detector and their application.

  17. Radiation practices. Annual report 2008

    International Nuclear Information System (INIS)

    Rantanen, E.

    2009-09-01

    1775 safety licences for the use of radiation were current at the end of 2008. 1831 responsible parties were engaged in notifiable licence-exempt dental X-ray activities. Use of radiation was controlled through regular inspections performed at places of use, test packages sent by post to dental X-ray facilities and maintenance of the Dose Register. Radiation safety guides were also published and research was conducted in support of regulatory control. STUK conducted 424 inspections of licensed practices and 18 inspections of notifiable licence-exempt dental X-ray practices in 2008. 209 repair orders and recommendations were issued. Use of one appliance was prohibited. A total of just over 11 500 workers were subject to individual monitoring in 2008, and about 140 000 dose entries were made in the Dose Register maintained by STUK. Regulatory control of natural radiation focused on radon at workplaces and exposure of aircrews to cosmic radiation. 89 workplaces including a total of 201 work areas were subject to radon monitoring during 2008. Some 3700 pilots and cabin crew members were monitored for exposure to cosmic radiation. Metrological activities continued with calibration and development work as in previous years. Regulatory control of the use of non-ionizing radiation in 2008 focused particularly on mobile phones, sunbeds and lasers. Ten mobile phone types and five baby monitors were tested in market surveillance of wireless communication devices. 25 sunbed facilities were inspected and nine laser display inspections were performed. There were 22 abnormal incidents involving the use of radiation in 2008. Seventeen of these incidents concerned the use of radiation in industry, research or transportation, four concerned the use of radiation in health care, and one concerned the use of non-ionizing radiation. None of these incidents had serious consequences. (orig.)

  18. Radiation ray measuring device

    International Nuclear Information System (INIS)

    Maekawa, Tatsuyuki; Ida, Masaki.

    1997-01-01

    The present invention provides a chained-radiation ray monitoring system which can be applied to an actual monitoring system of a nuclear power plant or the like. Namely, this device comprises a plurality of scintillation detectors. Each of the detectors has two light take-out ports for emitting light corresponding to radiation rays irradiated from the object of the measurement to optical fibers. In addition, incident light from the optical fiber by way of one of the light take-out optical ports is transmitted to the other of the ports and sent from the other optical port to the fibers. Plurality sets of measuring systems are provided in which each of the detectors are disposed corresponding to a plurality of objects to be measured. A signal processing device is (1) connected with optical fibers of plurality sets of measuring systems in conjunction, (2) detects the optical pulses inputted from the optical fibers to identify the detector from which the optical pulses are sent and (3) measures the amount of radiation rays detected by the identified detector. As a result, the device of the present invention can form a measuring system with redundancy. (I.S.)

  19. Approval of devices and facilities using ionizing radiations for medical purposes

    International Nuclear Information System (INIS)

    1977-01-01

    This Order made by the Ministers of Health and Social Security, Agriculture and Labour amends a previous Decree of 23 April 1969 in particular concerning the classification of medical or dental radiodiagnostic devices subject to approval. The technical conditions to be complied with for such devices and facilities have also been amended. Finally, it is provided that, as regards facilities with heavy equipment subject to licensing (Act of 31 December 1970), approval is subject to compliance with the licensing conditions and is requested together with the application for a licence. (NEA) [fr

  20. Radiation-Tolerance Assessment of a Redundant Wireless Device

    Science.gov (United States)

    Huang, Q.; Jiang, J.

    2018-01-01

    This paper presents a method to evaluate radiation-tolerance without physical tests for a commercial off-the-shelf (COTS)-based monitoring device for high level radiation fields, such as those found in post-accident conditions in a nuclear power plant (NPP). This paper specifically describes the analysis of radiation environment in a severe accident, radiation damages in electronics, and the redundant solution used to prolong the life of the system, as well as the evaluation method for radiation protection and the analysis method of system reliability. As a case study, a wireless monitoring device with redundant and diversified channels is evaluated by using the developed method. The study results and system assessment data show that, under the given radiation condition, performance of the redundant device is more reliable and more robust than those non-redundant devices. The developed redundant wireless monitoring device is therefore able to apply in those conditions (up to 10 M Rad (Si)) during a severe accident in a NPP.

  1. Radiation sterilization of medical devices

    International Nuclear Information System (INIS)

    Kaluska, I.; Stuglik, Z.

    1996-01-01

    Overview of sterilization methods of medical devices has been given, with the special stress put on radiation sterilization. A typical validation program for radiation sterilization has been shown and also a comparison of European and ISO standards concerning radiation sterilization has been discussed. (author). 13 refs, 1 fig., 2 tabs

  2. Radiation monitoring device

    International Nuclear Information System (INIS)

    Sato, Toshifumi.

    1993-01-01

    The device of the present invention concerns a reactor start-up region monitor of a nuclear power plant. In an existent start-up region monitor, bias voltage is limited, if the reactor moves to a power region, in order to prevent degradation of radiation detectors. Accordingly, since the power is lower than an actual reactor power, the reactor power can not be monitored. The device of the present invention comprises a memory means for previously storing a Plateau's characteristic of the radiation detectors and a correction processing means for obtaining a correction coefficient in accordance with the Plateau's characteristic to correct and calculate the reactor power when the bias voltage is limited. With such a constitution, when the reactor power exceeds a predetermined value and the bias voltage is limited, the correction coefficient can be obtained by the memory means and the correction processing means. Corrected reactor power can also be obtained from the start-up region monitor by the correction coefficient. As a result, monitoring of the reactor power can be continued while preventing degradation of the radiation detector even if the bias voltage is limited. (I.S.)

  3. Radiation effects in charge coupled devices

    International Nuclear Information System (INIS)

    Williams, R.A.; Nelson, R.D.

    1975-01-01

    Charge coupled devices (CCD s) exhibit a number of advantages (low cost, low power, high bit density) in their several applications (serial memories, imagers, digital filters); however, fairly elementary theoretical considerations indicate that they will be very vulnerable to permanent radiation damage, by both neutrons and ionizing radiation, and to transient upset by pulsed ionizing radiation. Although studies of permanent ionizing-radiation damage in CCD's have been reported, little information has been published concerning their overall nuclear radiation vulnerability. This paper presents a fairly comprehensive experimental study of radiation effects in a 256-cell surface-channel, CCD shift-register. A limited amount of similar work is also presented for a 128-cell surface-channel device and a 130 cell peristaltic CCD shift register. The radiation effects phenomena discussed herein, include transient-ionizing-radiation responses, permanent ionizing- radiation damage to transfer efficiency, charge-carrying capacity and input transfer gate bias, and neutron damage to storage time--determined from dark current and charge-up time measurements

  4. Counterbalanced radiation detection device

    International Nuclear Information System (INIS)

    Platz, W.

    1986-01-01

    A counterbalanced radiation detection device is described which consists of: (a) a base; (b) a radiation detector having a known weight; (c) means connected with the radiation detector and the base for positioning the radiation detector in different heights with respect to the base; (d) electronic component means movably mounted on the base for counterbalancing the weight of the radiation detector; (e) means connected with the electronic component means and the radiation detector positioning means for positioning the electronic component means in different heights with respect to the base opposite to the heights of the radiation detector; (f) means connected with the radiation detector and the base for shifting the radiation detector horizontally with respect to the base; and (g) means connected with the electronic component means and the radiation detector shifting means for shifting the electronic component means horizontally with respect to the base in opposite direction to shifting of the radiation detector

  5. Prospects of radiation sterilization of medical devices

    International Nuclear Information System (INIS)

    Hosobuchi, Kazunari

    1992-01-01

    Since radiation sterilization was first introduced in the United States in 1956 in the field of disposable medical devices, it has become an indispensable technique for sterilization because of the following reasons: (1) introduction into dialyzers, (2) introduction in medical device makers, (3) development of disposable medical devices associated with developing both high molecular chemistry and cool sterilization, (4) rationality of sterilization process, and (5) problems of sterilization with ethylene oxide gas. To promote the further development of radiation sterilization, the following items are considered necessary: (1) an increase in the number of facilities for radiation sterilization, (2) recommendation of the international standardization of sterilization method, (3) decrease in radiation doses associated with sterilization, (4) development of electron accelerators and bremsstrahlung equipments for radiation sources, and (5) simplification of sterilization process management. Factors precluding the development of radiation sterilization are: (1) development of other methods than radiation sterilization, (2) development of technique for sterile products, (3) high facility cost, (4) high irradiation cost, (5) benefits and limits of sterilization markets, and (6) influences of materials. (N.K.)

  6. Radiation hardening of MOS devices by boron

    International Nuclear Information System (INIS)

    Danchenko, V.

    1975-01-01

    A novel technique is disclosed for radiation hardening of MOS devices and specifically for stabilizing the gate threshold potential at room temperature of a radiation subjected MOS field-effect device of the type having a semiconductor substrate, an insulating layer of oxide on the substrate, and a gate electrode disposed on the insulating layer. In the preferred embodiment, the novel inventive technique contemplates the introduction of boron into the insulating oxide, the boron being introduced within a layer of the oxide of about 100A to 300A thickness immediately adjacent the semiconductor-insulator interface. The concentration of boron in the oxide layer is preferably maintained on the order of 10 atoms/ cm 3 . The novel technique serves to reduce and substantially annihilate radiation induced positive gate charge accumulations, which accumulations, if not eliminated, would cause shifting of the gate threshold potential of a radiation subjected MOS device, and thus render the device unstable and/or inoperative. (auth)

  7. Valuing commercial radio licences

    NARCIS (Netherlands)

    Kerste, M.; Poort, J.; van Eijk, N.

    2011-01-01

    Within the EU Regulatory Framework, licensees for commercial radio broadcasting may be charged a fee to ensure optimal allocation of scarce resources but not to maximize public revenues. In this paper, it is described how such a fee can be determined for the purpose of licence renewal or extension.

  8. Radiation detection device and a radiation detection method

    International Nuclear Information System (INIS)

    Blum, A.

    1975-01-01

    A radiation detection device is described including at least one scintillator in the path of radiation emissions from a distributed radiation source; a plurality of photodetectors for viewing each scintillator; a signal processing means, a storage means, and a data processing means that are interconnected with one another and connected to said photodetectors; and display means connected to the data processing means to locate a plurality of radiation sources in said distributed radiation source and to provide an image of the distributed radiation sources. The storage means includes radiation emission response data and location data from a plurality of known locations for use by the data processing means to derive a more accurate image by comparison of radiation responses from known locations with radiation responses from unknown locations. (auth)

  9. The effects of cosmic radiation on implantable medical devices

    International Nuclear Information System (INIS)

    Bradley, P.

    1996-01-01

    Metal oxide semiconductor (MOS) integrated circuits, with the benefits of low power consumption, represent the state of the art technology for implantable medical devices. Three significant sources of radiation are classified as having the ability to damage or alter the behavior of implantable electronics; Secondary neutron cosmic radiation, alpha particle radiation from the device packaging and therapeutic doses(up to 70 Gγ) of high energy radiation used in radiation oncology. The effects of alpha particle radiation from the packaging may be eliminated by the use of polyimide or silicone rubber die coatings. The relatively low incidence of therapeutic radiation incident on an implantable device and the use of die coating leaves cosmic radiation induced secondary neutron single event upset (SEU) as the main pervasive ionising radiation threat to the reliability of implantable devices. A theoretical model which predicts the susceptibility of a RAM cell to secondary neutron cosmic radiation induced SEU is presented. The model correlates well within the statistical uncertainty associated with both the theoretical and field estimate. The predicted Soft Error Rate (SER) is 4.8 x l0 -12 upsets/(bit hr) compared to an observed upset rate of 8.5 x 10 -12 upsets/(bit hr) from 20 upsets collected over a total of 284672 device days. The predicted upset rate may increase by up to 20% when consideration is given to patients flying in aircraft The upset rate is also consistent with the expected geographical variations of the secondary cosmic ray neutron flux, although insufficient upsets precluded a statistically significant test. This is the first clinical data set obtained indicating the effects of cosmic radiation on implantable devices. Importantly, it may be used to predict the susceptibility of future to the implantable device designs to the effects of cosmic radiation

  10. Medical Devices; General Hospital and Personal Use Devices; Classification of the Ultraviolet Radiation Chamber Disinfection Device. Final order.

    Science.gov (United States)

    2015-11-20

    The Food and Drug Administration (FDA or the Agency) is classifying the ultraviolet (UV) radiation chamber disinfection device into class II (special controls). The special controls that will apply to the device are identified in this order and will be part of the codified language for the UV radiation chamber disinfection device classification. The Agency is classifying the device into class II (special controls) in order to provide a reasonable assurance of safety and effectiveness of the device.

  11. Effects of radiation on MOS structures and silicon devices

    International Nuclear Information System (INIS)

    Braeunig, D.; Fahrner, W.

    1983-02-01

    A comprehensive view of radiation effects on MOS structures and silicon devices is given. In the introduction, the interaction of radiation with semiconductor material is presented. In the next section, the electrical degradation of semiconductor devices due to this interaction is discussed. The commonly used hardening techniques are shown. The last section deals with testing of radiation hardness of devices. (orig.) [de

  12. Advanced Small Animal Conformal Radiation Therapy Device.

    Science.gov (United States)

    Sharma, Sunil; Narayanasamy, Ganesh; Przybyla, Beata; Webber, Jessica; Boerma, Marjan; Clarkson, Richard; Moros, Eduardo G; Corry, Peter M; Griffin, Robert J

    2017-02-01

    We have developed a small animal conformal radiation therapy device that provides a degree of geometrical/anatomical targeting comparable to what is achievable in a commercial animal irradiator. small animal conformal radiation therapy device is capable of producing precise and accurate conformal delivery of radiation to target as well as for imaging small animals. The small animal conformal radiation therapy device uses an X-ray tube, a robotic animal position system, and a digital imager. The system is in a steel enclosure with adequate lead shielding following National Council on Radiation Protection and Measurements 49 guidelines and verified with Geiger-Mueller survey meter. The X-ray source is calibrated following AAPM TG-61 specifications and mounted at 101.6 cm from the floor, which is a primary barrier. The X-ray tube is mounted on a custom-made "gantry" and has a special collimating assembly system that allows field size between 0.5 mm and 20 cm at isocenter. Three-dimensional imaging can be performed to aid target localization using the same X-ray source at custom settings and an in-house reconstruction software. The small animal conformal radiation therapy device thus provides an excellent integrated system to promote translational research in radiation oncology in an academic laboratory. The purpose of this article is to review shielding and dosimetric measurement and highlight a few successful studies that have been performed to date with our system. In addition, an example of new data from an in vivo rat model of breast cancer is presented in which spatially fractionated radiation alone and in combination with thermal ablation was applied and the therapeutic benefit examined.

  13. Radiation practices. Annual report 2002

    International Nuclear Information System (INIS)

    Rantanen, E.

    2003-06-01

    A total of 1820 safety licences granted for the use of radiation in Finland were current at the end of 2002. There were also 2037 undertakings for dental X-ray diagnostics (licencefree). The Safety Licence Register of the Radiation and Nuclear Safety Authority (STUK) listed 14 120 radiation devices and 262 radionuclide laboratories. In 2002, STUK performed 401 inspections of licensed practices and 25 inspections of licence-free dental X-ray practices. Restrictions were ordered on the use of one device. Repairs were ordered in 116 cases and recommended in 55 cases. No remarks were given in 254 cases. Imports of radioactive substances amounted to 110 157 GBq and exports totalled 22 359 GBq. Short-lived radionuclides produced in Finland amounted to 42 487 GBq. The STUK interim storage for radioactive wastes received 65 batches of low-level wastes. A total of 11 190 workers were individually monitored for radiation exposure at 1176 workplaces. Of these workers, some 32% were category A workers and 67% category B workers. In no case were annual dose limits exceeded. The total dose in the use of radiation and nuclear energy recorded in the STUK Dose Register was 6.35 Sv. The mean doses in typical diagnostic X-ray procedures based on phantom measurements were below the reference levels issued by the European Community, the IAEA and STUK. Accuracy of the therapeutic doses underlying good therapeutic results in radiotherapy has remained within acceptable limits, and no excessive doses jeopardizing the safety of therapy have occurred. In the regulatory control of natural radiation, inspection reports requesting performance of radon repairs or measurements of radon concentrations were sent to 145 enterprises. Underground radon inspections were performed in 4 mines and 7 excavation sites. The mean effective dose to aircraft crew caused by cosmic radiation was 1.6 mSv. Ministry of Social Affairs and Health Decree on the Limitation of Public Exposure to Non-Ionizing Radiation

  14. Detection device of dangerous radiation for the living beings

    International Nuclear Information System (INIS)

    Lacoste, F.

    1991-01-01

    This invention is about a portable device able to measure dose rates or doses of gamma, ultraviolet and X radiation or charged particles. This device is composed of a radiation detector, a calculator of the accumulate dose and a memory to store the data. This device has a credit card format

  15. Radiation sensitive devices and systems for detection of radioactive materials and related methods

    Science.gov (United States)

    Kotter, Dale K

    2014-12-02

    Radiation sensitive devices include a substrate comprising a radiation sensitive material and a plurality of resonance elements coupled to the substrate. Each resonance element is configured to resonate responsive to non-ionizing incident radiation. Systems for detecting radiation from a special nuclear material include a radiation sensitive device and a sensor located remotely from the radiation sensitive device and configured to measure an output signal from the radiation sensitive device. In such systems, the radiation sensitive device includes a radiation sensitive material and a plurality of resonance elements positioned on the radiation sensitive material. Methods for detecting a presence of a special nuclear material include positioning a radiation sensitive device in a location where special nuclear materials are to be detected and remotely interrogating the radiation sensitive device with a sensor.

  16. Radiation practices. Annual report 2011

    Energy Technology Data Exchange (ETDEWEB)

    Rantanen, E. (ed.)

    2012-09-15

    1791 safety licences for the use of radiation were current at the end of 2011. 1702 responsible parties were engaged in notifiable licence-exempt dental X-ray activities. Use of radiation was controlled through regular inspections performed at places of use, test packages sent by post to dental X-ray facilities and maintenance of the Dose Register. Radiation safety guides were also published and research was conducted in support of regulatory control. The Radiation and Nuclear Safety Authority (STUK) conducted 575 inspections of licensed practices in 2011. 633 repair orders and recommendations were issued in the course of inspections. A total of nearly 11 700 workers were subject to individual monitoring in 2011 and about 143 000 dose entries were made in the Dose Register maintained by STUK. Regulatory control of natural radiation focused on radon at workplaces and exposure of aircrews to cosmic radiation. 166 workplaces including a total of 288 work areas were subject to radon monitoring during 2011. Just over 3600 cockpit and cabin crew members were monitored for exposure to cosmic radiation. STUK was involved in four ionizing radiation research projects, and also took part in an international expert group evaluation of STUK research activities. New alpha and beta sources were procured for metrological activities and a Co-60 irradiation device procured in 2010 was installed and taken into use. Calibration and testing services continued as in previous years. Regulatory control of the use of non-ionizing radiation in 2011 focused particularly on mobile phones, sunbeds and lasers. Orders were issued to 5 responsible parties to discontinue the use of tattoo removal lasers. 7 sunbed facilities were inspected and 10 on-site laser display inspections were performed. Five mobile phone types were tested in market surveillance of wireless communication devices. Non-ionizing radiation research activities were also subjected to the evaluation of STUK research activities

  17. Earning the social licence for nuclear operations

    International Nuclear Information System (INIS)

    Duguay, A.K.; Hoornweg, B.J.

    2010-01-01

    In addition to safe nuclear operation, a critical component of earning the social licence is effective communication. This paper outlines development of a communications strategy contributing to overall utility operation and project goals through: 1) Relationships with employees, host communities and the general public that are transparent and honest; 2) Processes that effectively interconnect the internal and external communications; and 3) Organizational leadership models that support communication excellence. With strategic development of these three focus areas the nuclear operator will contribute to increased support of the operator's own licence to operate and of support for the nuclear industry as a whole. (author)

  18. Measuring ionizing radiation with a mobile device

    Science.gov (United States)

    Michelsburg, Matthias; Fehrenbach, Thomas; Puente León, Fernando

    2012-02-01

    In cases of nuclear disasters it is desirable to know one's personal exposure to radioactivity and the related health risk. Usually, Geiger-Mueller tubes are used to assess the situation. Equipping everyone with such a device in a short period of time is very expensive. We propose a method to detect ionizing radiation using the integrated camera of a mobile consumer device, e.g., a cell phone. In emergency cases, millions of existing mobile devices could then be used to monitor the exposure of its owners. In combination with internet access and GPS, measured data can be collected by a central server to get an overview of the situation. During a measurement, the CMOS sensor of a mobile device is shielded from surrounding light by an attachment in front of the lens or an internal shutter. The high-energy radiation produces free electrons on the sensor chip resulting in an image signal. By image analysis by means of the mobile device, signal components due to incident ionizing radiation are separated from the sensor noise. With radioactive sources present significant increases in detected pixels can be seen. Furthermore, the cell phone application can make a preliminary estimate on the collected dose of an individual and the associated health risks.

  19. Devices for obtaining information about radiation sources

    International Nuclear Information System (INIS)

    Tosswill, C.H.

    1981-01-01

    The invention provides a sensitive, fast high-resolution device for obtaining information about the distribution of gamma and X-radiation sources and provides a radiation detector useful in such a device. It comprises a slit collimator with a multiplicity of slits each with slit-defining walls of material and thickness to absorb beam components impinging on them. The slits extend further in one direction than the other. The detector for separately detecting beam components passing through the slits also provides data output signals. It comprises a plurality of radiation transducing portions which are not photoconductor elements each at the end of a slit. A positioner operates to change the transverse position of the slits and radiation transducing portions relative to the source, wherein each radiation transducing element is positioned within its respective slit between the slit defining walls. Full details and preferred embodiments are given. (U.K.)

  20. Devices for obtaining information about radiation sources

    International Nuclear Information System (INIS)

    Tosswill, C.H.

    1981-01-01

    The invention provides a sensitive, fast, high-resolution device for obtaining information about the distribution of gamma and X-radiation sources and provides a radiation detector useful in such a device. It comprises a slit collimator with a multiplicity of slits each with slit-defining walls of material and thickness to absorb beam components impinging on them. The slits extend further in one transverse direction than the other. The detector for separately detecting beam components passing through the slits also provides data output signals. It comprises a plurality of radiation transducing portions, each at the end of a slit. A positioner changes the transverse position of the slits and radiation transducer (a photoconductor) relative to the source. Applications are in nuclear medicine and industry. Full details and preferred embodiments are given. (U.K.)

  1. Radiation sensitive area detection device and method

    Science.gov (United States)

    Carter, Daniel C. (Inventor); Hecht, Diana L. (Inventor); Witherow, William K. (Inventor)

    1991-01-01

    A radiation sensitive area detection device for use in conjunction with an X ray, ultraviolet or other radiation source is provided which comprises a phosphor containing film which releases a stored diffraction pattern image in response to incoming light or other electromagnetic wave. A light source such as a helium-neon laser, an optical fiber capable of directing light from the laser source onto the phosphor film and also capable of channelling the fluoresced light from the phosphor film to an integrating sphere which directs the light to a signal processing means including a light receiving means such as a photomultiplier tube. The signal processing means allows translation of the fluoresced light in order to detect the original pattern caused by the diffraction of the radiation by the original sample. The optical fiber is retained directly in front of the phosphor screen by a thin metal holder which moves up and down across the phosphor screen and which features a replaceable pinhole which allows easy adjustment of the resolution of the light projected onto the phosphor film. The device produces near real time images with high spatial resolution and without the distortion that accompanies prior art devices employing photomultiplier tubes. A method is also provided for carrying out radiation area detection using the device of the invention.

  2. Method and device for controlling radiation

    International Nuclear Information System (INIS)

    Wilhelm, G.M.

    1979-01-01

    A device which will control radiation emanating from colour television sets is described. It consists of two transparent plates the same size as a television screen, with a thin layer of transparent mineral oil sealed between them. The device may be installed by the manufacturer or bought separately and installed by the user. (LL)

  3. Radiation dose rate measuring device

    International Nuclear Information System (INIS)

    Sorber, R.

    1987-01-01

    A portable device is described for in-field usage for measuring the dose rate of an ambient beta radiation field, comprising: a housing, substantially impervious to beta radiation, defining an ionization chamber and having an opening into the ionization chamber; beta radiation pervious electrically-conductive window means covering the opening and entrapping, within the ionization chamber, a quantity of gaseous molecules adapted to ionize upon impact with beta radiation particles; electrode means disposed within the ionization chamber and having a generally shallow concave surface terminating in a generally annular rim disposed at a substantially close spacing to the window means. It is configured to substantially conform to the window means to define a known beta radiation sensitive volume generally between the window means and the concave surface of the electrode means. The concave surface is effective to substantially fully expose the beta radiation sensitive volume to the radiation field over substantially the full ambient area faced by the window means

  4. Earning the social licence for nuclear operations

    Energy Technology Data Exchange (ETDEWEB)

    Duguay, A.K. [New Brunswick Power, New Brunswick (Canada); Hoornweg, B.J. [Ontario Power Generation, Ontario (Canada)

    2010-07-01

    In addition to safe nuclear operation, a critical component of earning the social licence is effective communication. This paper outlines development of a communications strategy contributing to overall utility operation and project goals through: 1) Relationships with employees, host communities and the general public that are transparent and honest; 2) Processes that effectively interconnect the internal and external communications; and 3) Organizational leadership models that support communication excellence. With strategic development of these three focus areas the nuclear operator will contribute to increased support of the operator's own licence to operate and of support for the nuclear industry as a whole. (author)

  5. Terrestrial radiation effects in ULSI devices and electronic systems

    CERN Document Server

    Ibe, Eishi H

    2014-01-01

    A practical guide on how mathematical approaches can be used to analyze and control radiation effects in semiconductor devices within various environments Covers faults in ULSI devices to failures in electronic systems caused by a wide variety of radiation fields, including electrons, alpha -rays, muons, gamma rays, neutrons and heavy ions. Readers will learn the environmental radiation features at the ground or avionics altitude. Readers will also learn how to make numerical models from physical insight and what kind of mathematical approaches should be implemented to analyze the radiation effects. A wide variety of mitigation techniques against soft-errors are reviewed and discussed. The author shows how to model sophisticated radiation effects in condensed matter in order to quantify and control them. The book provides the reader with the knowledge on a wide variety of radiation fields and their effects on the electronic devices and systems. It explains how electronic systems including servers and rout...

  6. Radiation detection device

    International Nuclear Information System (INIS)

    Peschmann, Kristian.

    1982-01-01

    A radiation detector suitable for use in computer tomography device has an ionization chamber which comprises a high voltage electrode, a collector electrode, a high voltage source having two terminals, one connected to the high voltage electrode, current measuring means having two terminals, one connected to the high voltage source and the other to the collector electrode, and an auxilliary electrode near and parallel to the entrance window of the device, having one adjacent to the high voltage electrode and the other adjacent but not connected to the collector electrode. The auxilliary electrode is connected to the high voltage source. In this way the electric field between the high voltage and collector electrodes is made homogeneous in the vicinity of the auxilliary electrode, improving the measuring speed of the detector

  7. Strategic management of the licence portfolio

    International Nuclear Information System (INIS)

    Killingland, Arild

    1998-01-01

    This presentation discusses the secondary market for purchase, sale and exchange of licences on the Norwegian Continental Shelf. An efficient secondary market is necessary for the operations on the Shelf to work well. Two examples of major transactions made by Statoil are given, Rubicon and Aasgard. Rubicon is the most comprehensive portfolio operation made on the Norwegian Shelf and probably the largest exchange transaction across national frontiers. Rubicon was undertaken because Statoil wanted to create bigger values in the portfolio by increasing the owner parts in core areas. One effect of Rubicon was its contribution to increasing the extent of the activities in the UK such that there is a basis for achieving Statoil's ambitions for the international core areas, which is that they shall be developed to produce 100.000 barrels of oil equivalents per day within a defined period. Statoil is presently positioned to develop core areas in five regions outside the Norwegian Shelf: the Caspian Sea, Venezuela, Angola, Gulf of Mexico and UK. The Aasgard licence exchange transactions were necessary to achieve a co-ordinated of the relevant licences and balanced owner positions in the fields that were established. The Aasgard field is being developed with a production ship for oil- and condensate production. Production will start in 1998. The gas will be produced from the year 2000, from a floating platform. Finally, there is a discussion of trends in the portfolio market

  8. Tunable radiation emitting semiconductor device

    NARCIS (Netherlands)

    2009-01-01

    A tunable radiation emitting semiconductor device includes at least one elongated structure at least partially fabricated from one or more semiconductor materials exhibiting a bandgap characteristic including one or more energy transitions whose energies correspond to photon energies of light

  9. Radiation sensitive solid state devices

    International Nuclear Information System (INIS)

    Shannon, J.M.; Ralph, J.E.

    1975-01-01

    A solid state radiation sensitive device is described employing JFETs as the sensitive elements. Two terminal construction is achieved by using a common conductor to capacitively couple to the JFET gate and to one of the source and drain connections. (auth)

  10. International Standards for Radiation Sterilization of Medical Devices

    International Nuclear Information System (INIS)

    Miller, A.

    2007-01-01

    For a terminally sterilized medical device to be designated '' STERILE '', probability of finding the viable micro-organisms in the device shall be equal to or less than 1 x 10 -6 (EN 556-1:2001: Sterilization of medical devices - Requirements for medical devices to be designated '' STERILE '' - Part 1: Requirements for terminally sterilized medical devices). Author presents the main legal aspects of the international standards for radiation sterilization of medical devices

  11. Space and military radiation effects in silicon-on-insulator devices

    International Nuclear Information System (INIS)

    Schwank, J.R.

    1996-09-01

    Advantages in transient ionizing and single-event upset (SEU) radiation hardness of silicon-on-insulator (SOI) technology spurred much of its early development. Both of these advantages are a direct result of the reduced charge collection volume inherent to SOI technology. The fact that SOI transistor structures do not include parasitic n-p-n-p paths makes them immune to latchup. Even though considerable improvement in transient and single-event radiation hardness can be obtained by using SOI technology, there are some attributes of SOI devices and circuits that tend to limit their overall hardness. These attributes include the bipolar effect that can ultimately reduce the hardness of SOI ICs to SEU and transient ionizing radiation, and charge buildup in buried and sidewall oxides that can degrade the total-dose hardness of SOI devices. Nevertheless, high-performance SOI circuits can be fabricated that are hardened to both space and nuclear radiation environments, and radiation-hardened systems remain an active market for SOI devices. The effects of radiation on SOI MOS devices are reviewed

  12. LICENCE, DESIGN AND MARKETING EXPERIENCE RELATING TO A PRODUCT OR PROCESS

    Directory of Open Access Journals (Sweden)

    LIVIU NEAMŢU

    2013-08-01

    Full Text Available Contracting a licence is buying or selling contract of technology, design and marketing experiencerelating to a product or process, and involves the contracting of knowledge and know-how. The granting of aninternational licence takes place when a company provides, in return for a fee or royalties, technology needed byanother firm to run business operations on a foreign market. When in this form, the granting of the licencerequires at least one of the following items: a brand name; operating experience; manufacturing technology;access to patents and trade secrets/industrial. Company that grants the licence get access on a foreign marketwith very low investment and, in many cases, the benefits of investment and market knowledge of a competentlocal firms. The company that received the licence get access to foreign technology, with a very smallinvestment. There are several very obvious advantages of activity under the license on international markets.The granting of a licence can improve cash flow situation for the company that attaches. Because the license ontechnology allows companies to bring products to market faster, the company enjoys early advantage of apositive balance of cash flow. In addition, obtaining a license means lower development costs. The licensedactivity may mean fewer profits in the long run. Immediate benefits of easy access to new technology, lower costsand the development of an early cash flow are attractive advantages of contracting a licence.

  13. Radiation detector device for measuring ionizing radiation

    International Nuclear Information System (INIS)

    Brake, D. von der.

    1983-01-01

    The device contains a compensating filter circuit, which guarantees measurement of the radiation dose independent of the energy or independent of the energy and direction. The compensating filter circuit contains a carrier tube of a slightly absorbing metal with an order number not higher than 35, which surrounds a tubular detector and which carries several annular filter parts on its surface. (orig./HP) [de

  14. Particle interaction and displacement damage in silicon devices operated in radiation environments

    International Nuclear Information System (INIS)

    Leroy, Claude; Rancoita, Pier-Giorgio

    2007-01-01

    Silicon is used in radiation detectors and electronic devices. Nowadays, these devices achieving submicron technology are parts of integrated circuits of large to very large scale integration (VLSI). Silicon and silicon-based devices are commonly operated in many fields including particle physics experiments, nuclear medicine and space. Some of these fields present adverse radiation environments that may affect the operation of the devices. The particle energy deposition mechanisms by ionization and non-ionization processes are reviewed as well as the radiation-induced damage and its effect on device parameters evolution, depending on particle type, energy and fluence. The temporary or permanent damage inflicted by a single particle (single event effect) to electronic devices or integrated circuits is treated separately from the total ionizing dose (TID) effect for which the accumulated fluence causes degradation and from the displacement damage induced by the non-ionizing energy-loss (NIEL) deposition. Understanding of radiation effects on silicon devices has an impact on their design and allows the prediction of a specific device behaviour when exposed to a radiation field of interest

  15. Nuclear valves and the licencing authority

    International Nuclear Information System (INIS)

    Stevens-Guille, P.D.

    1977-02-01

    Valve problems relevant to licencing authorities are discussed. It is suggested that the probability of valve failure should be given more emphasis in safety analysis. Problems of stress analysis, codes, seismic effects, malfunction and leakage are discussed and programmes aimed at solving future problems are outlined

  16. Transient radiation effects in GaAs semiconductor devices

    International Nuclear Information System (INIS)

    Chang, J.Y.; Stauber, M.; Ezzeddine, A.; Howard, J.W.; Constantine, A.G.; Becker, M.; Block, R.C.

    1988-01-01

    This paper describes an ongoing program to identify the response of GaAs devices to intense pulses of ionizing radiation. The program consists of experimental measurements at the Rensselaer Polytechnic Institute's RPI electron linear accelerator (Linac) on generic GaAs devices built by Grumman Tachonics Corporation and the analysis of these results through computer simulation with the circuit model code SPICE (including radiation effects incorporated in the variations TRISPICE and TRIGSPICE and the device model code PISCES IIB). The objective of this program is the observation of the basic response phenomena and the development of accurate simulation tools so that results of Linac irradiations tests can be understood and predicted

  17. Remaining authorized gas exports under long-term licences as of 1 November 1995

    International Nuclear Information System (INIS)

    1995-01-01

    A statistical base of information on natural gas exports authorized under long-term licences to markets in the U.S. as of November 1, 1995, was provided. The first part of the report focused on the total licensed exports to the U.S. while the second part provided a breakdown of the licensed export volumes by U.S. market regions. The National Energy Board Act empowers the National Energy Board to issue licences and orders for the export of natural gas from Canada. Licences are issued for long-term periods (over 2 years) and orders for short-term periods (2 years or less). Each individual export licence contains terms and conditions including the duration of the licence, the point of export where the gas may leave Canada, and the maximum allowable volumes that may be exported daily, annually, and throughout the term of the licence. 17 figs

  18. Seniors’ unmet mobility needs – how important is a driving licence?

    DEFF Research Database (Denmark)

    Haustein, Sonja; Siren, Anu Kristiina

    2014-01-01

    Previous studies have come to different conclusions regarding how important a driving licence is for seniors to fulfil their mobility needs. We investigated this question based on three groups of Danish seniors: persons who were licensed as drivers (‘‘drivers’’); persons who have never been...... it became insignificant for unmet shopping needs. The effect of never having had a licence was hardly affected by the inclusion of control variables. The results emphasise the importance of a driving licence in fulfilling seniors’ mobility needs. Contrary to our hypotheses, more experience with, and better...

  19. Radiation dose distributions due to sudden ejection of cobalt device.

    Science.gov (United States)

    Abdelhady, Amr

    2016-09-01

    The evaluation of the radiation dose during accident in a nuclear reactor is of great concern from the viewpoint of safety. One of important accident must be analyzed and may be occurred in open pool type reactor is the rejection of cobalt device. The study is evaluating the dose rate levels resulting from upset withdrawal of co device especially the radiation dose received by the operator in the control room. Study of indirect radiation exposure to the environment due to skyshine effect is also taken into consideration in order to evaluate the radiation dose levels around the reactor during the ejection trip. Microshield, SHLDUTIL, and MCSky codes were used in this study to calculate the radiation dose profiles during cobalt device ejection trip inside and outside the reactor building. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. The transient radiation effects and hardness of programmed device

    International Nuclear Information System (INIS)

    Du Chuanhua; Xu Xianguo; Zhao Hailin

    2014-01-01

    A review and summary of research and development in the investigation of transient ionizing radiation effects in device and cirviut is presented. The transient ionizing radiation effects in two type of programmed device, that's 32 bit Microcontroller and antifuse FPGA, were studied. The expeiment test data indicate: The transient ionizing radiation effects of 32 bit Microcontroller manifested self-motion restart and Latchup, the Latchup threshold was 5 × 10"7 Gy (Si)/s. The transient ionizing radiation effects of FPGA was reset, no Latchup. The relationship of circuit effects to physical mechanisms was analized. A new method of hardness in circiut design was put forward. (authors)

  1. Radiation dose distributions due to sudden ejection of cobalt device

    International Nuclear Information System (INIS)

    Abdelhady, Amr

    2016-01-01

    The evaluation of the radiation dose during accident in a nuclear reactor is of great concern from the viewpoint of safety. One of important accident must be analyzed and may be occurred in open pool type reactor is the rejection of cobalt device. The study is evaluating the dose rate levels resulting from upset withdrawal of co device especially the radiation dose received by the operator in the control room. Study of indirect radiation exposure to the environment due to skyshine effect is also taken into consideration in order to evaluate the radiation dose levels around the reactor during the ejection trip. Microshield, SHLDUTIL, and MCSky codes were used in this study to calculate the radiation dose profiles during cobalt device ejection trip inside and outside the reactor building. - Highlights: • This study aims to calculate the dose rate profiles after cobalt device ejection from open-pool-type reactor core. • MicroShield code was used to evaluate the dose rates inside the reactor control room. • McSKY code was used to evaluate the dose rates outside the reactor building. • The calculated dose rates for workers are higher than the permissible limits after 18 s from device ejection.

  2. Tm2+ luminescent materials for solar radiation conversion devices

    NARCIS (Netherlands)

    Van der Kolk, E.

    2015-01-01

    A solar radiation conversion device is described that comprises a luminescent Tm 2+ inorganic material for converting solar radiation of at least part of the UV and/or visible and/or infra red solar spectrum into infrared solar radiation, preferably said infrared solar radiation having a wavelength

  3. Renewal of the operation licence for Paks NPP

    International Nuclear Information System (INIS)

    Toth, Andras

    2002-01-01

    Full text: 1. Current situation - Hungarian legislation does not exclude Lr of the units; There are no detailed instructions how to renew the current licence after 'design lifetime'; There is only one type of Time Limited ageing Analyses in Final Safety Analysis Report: Rp embrittlement; Fatigue analyses, equipment qualification or other TLAA's are not included in the Far; There are a lot of statements without background documentation about the operability of certain equipment for 30 years; Ageing is managed as part of maintenance, test and ISI activities; FSAR has been elaborated on the basis of NRC Reg. Guide 1.70 and has to be updated yearly, but there are big gaps in the design bases information in comparison with R-G 1.70 requirements; Periodic Safety Review complies with guide 50-SG-O12 of the IAEA; it is to be submitted to RB every 10 years. 2. Preparatory activities, performed by HAEA - Studying IAEA documents related to ageing; Studying US NRC documents related to ageing and LR; Listing equipment, which needs ageing management; Identification of scope and structure of ageing analyses; Ageing analysis of selected equipment (provided by TSO VEIKI); Preparation of guides on ageing management in accordance with Hungarian regulations' structure; Studying NRC Reg. Guide 1.70 on FSAR and IAEA safety guide 50-SG-O12 on PSR (identification of gaps and overlaps in these documents); Comparison of international experience with Hungarian opportunities (identification of gaps in input information). 3. Lessons learned from preparatory activities - Design basis documentation of Paks NPP needs completion and re-evaluation; The ageing Management Program should cover all SSCs important to safety in consistent and auditable manner; Equipment qualification was not included in initial design basis therefore the EQ documentation is not complete and part of equipment does not comply with EQ requirements; Effective maintenance of technical condition of safety related equipment has

  4. Radiation effects on custom MOS devices

    International Nuclear Information System (INIS)

    Harris, R.

    1999-05-01

    This Thesis consists of four chapters: The first is primarily for background information on the effects of radiation on MOS devices and the theory of wafer bonding; the second gives a full discussion of all practical work carried out for manufacture of Field Effect test Capacitors, the third discusses manufacture of vacuum insulator Field Effect Transistors (FET's) and the fourth discusses the testing of these devices. Using a thermally bonded field effect capacitor structure, a vacuum dielectric was studied for use in high radiation environments with a view to manufacturing a CMOS compatible, micro machined transistor. Results are given in the form of high frequency C-V curves before and after a 120 kGy(Si), 12 MRad(Si), dose from a Co 60 source showing a 1 Volt shift. The work is then extended to the design and manufacture of a micro machined, under-etch technique, Field Effect Transistor for use in high radiation areas. Results are shown for Threshold, Subthreshold and Transfer characteristics before and after irradiation up to a total dose of 100kGy or 10MRad. The conclusion from this work is that it should be possible to commercially manufacture practical vacuum dielectric field effect transistors which are radiation hard to at least 120 kGy(Si). (author)

  5. Traffic safety and step-by-step driving licence for young people

    DEFF Research Database (Denmark)

    Tønning, Charlotte; Agerholm, Niels

    2017-01-01

    presents a review of safety effects from step-by-step driving licence schemes. Most of the investigated schemes consist of a step-by-step driving licence with Step 1) various tests and education, Step 2) a period where driving is only allowed together with an experienced driver and Step 3) driving without...... companion is allowed but with various restrictions and, in some cases, additional driving education and tests. In general, a step-by-step driving licence improves traffic safety even though the young people are permitted to drive a car earlier on. The effects from driving with an experienced driver vary......Young novice car drivers are much more accident-prone than other drivers - up to 10 times that of their parents' generation. A central solution to improve the traffic safety for this group is implementation of a step-by-step driving licence. A number of countries have introduced a step...

  6. Development of Quantum Devices and Algorithms for Radiation Detection and Radiation Signal Processing

    International Nuclear Information System (INIS)

    El Tokhy, M.E.S.M.E.S.

    2012-01-01

    The main functions of spectroscopy system are signal detection, filtering and amplification, pileup detection and recovery, dead time correction, amplitude analysis and energy spectrum analysis. Safeguards isotopic measurements require the best spectrometer systems with excellent resolution, stability, efficiency and throughput. However, the resolution and throughput, which depend mainly on the detector, amplifier and the analog-to-digital converter (ADC), can still be improved. These modules have been in continuous development and improvement. For this reason we are interested with both the development of quantum detectors and efficient algorithms of the digital processing measurement. Therefore, the main objective of this thesis is concentrated on both 1. Study quantum dot (QD) devices behaviors under gamma radiation 2. Development of efficient algorithms for handling problems of gamma-ray spectroscopy For gamma radiation detection, a detailed study of nanotechnology QD sources and infrared photodetectors (QDIP) for gamma radiation detection is introduced. There are two different types of quantum scintillator detectors, which dominate the area of ionizing radiation measurements. These detectors are QD scintillator detectors and QDIP scintillator detectors. By comparison with traditional systems, quantum systems have less mass, require less volume, and consume less power. These factors are increasing the need for efficient detector for gamma-ray applications such as gamma-ray spectroscopy. Consequently, the nanocomposite materials based on semiconductor quantum dots has potential for radiation detection via scintillation was demonstrated in the literature. Therefore, this thesis presents a theoretical analysis for the characteristics of QD sources and infrared photodetectors (QDIPs). A model of QD sources under incident gamma radiation detection is developed. A novel methodology is introduced to characterize the effect of gamma radiation on QD devices. The rate

  7. Evaluation of an enclosed ultraviolet-C radiation device for decontamination of mobile handheld devices.

    Science.gov (United States)

    Mathew, J Itty; Cadnum, Jennifer L; Sankar, Thriveen; Jencson, Annette L; Kundrapu, Sirisha; Donskey, Curtis J

    2016-06-01

    Mobile handheld devices used in health care settings may become contaminated with health care-associated pathogens. We demonstrated that an enclosed ultraviolet-C radiation device was effective in rapidly reducing methicillin-resistant Staphylococcus aureus, and with longer exposure times, Clostridium difficile spores, on glass slides and reducing contamination on in-use mobile handheld devices. Published by Elsevier Inc.

  8. Using a Commercial Ethernet PHY Device in a Radiation Environment

    Science.gov (United States)

    Parks, Jeremy; Arani, Michael; Arroyo, Roberto

    2014-01-01

    This work involved placing a commercial Ethernet PHY on its own power boundary, with limited current supply, and providing detection methods to determine when the device is not operating and when it needs either a reset or power-cycle. The device must be radiation-tested and free of destructive latchup errors. The commercial Ethernet PHY's own power boundary must be supplied by a current-limited power regulator that must have an enable (for power cycling), and its maximum power output must not exceed the PHY's input requirements, thus preventing damage to the device. A regulator with configurable output limits and short-circuit protection (such as the RHFL4913, rad hard positive voltage regulator family) is ideal. This will prevent a catastrophic failure due to radiation (such as a short between the commercial device's power and ground) from taking down the board's main power. Logic provided on the board will detect errors in the PHY. An FPGA (field-programmable gate array) with embedded Ethernet MAC (Media Access Control) will work well. The error detection includes monitoring the PHY's interrupt line, and the status of the Ethernet's switched power. When the PHY is determined to be non-functional, the logic device resets the PHY, which will often clear radiation induced errors. If this doesn't work, the logic device power-cycles the FPGA by toggling the regulator's enable input. This should clear almost all radiation induced errors provided the device is not latched up.

  9. Control of radioisotopes and radiation sources in Indonesia

    International Nuclear Information System (INIS)

    Ridwan, M.

    2001-01-01

    Radioisotopes and radiation sources are extensively used in Indonesia in medicine, industry, mining, agriculture and research. These materials are controlled by the regulatory authority, according to established legal procedures. The Nuclear Energy Control Board of Indonesia (BAPETEN), which was established in 1998 through the Nuclear Energy Act No. 10/1997, is entrusted with the control of any application of nuclear energy, including the application of radioisotopes and radiation sources, through regulation, licensing and inspection. The control is aimed to assure welfare, security and peace, the safety and health of workers and the public, and environmental protection. The number of licences issued to date is around 2400, consisting of 1600 licences for radioisotopes and radiation sources used in hospitals, 347 in radiography, 256 in industry, 53 in mining, and the rest in many other areas such as research and agriculture. A licence can cover one or more radioisotopes or radiation sources, depending on the location of the user institution. These radioisotopes and radiation sources are Co-60, Cs-137, Ir-192, Ra-226, Am-241, Sr-90, Kr-85, Pm-147, linear accelerator and X-ray, and short half-life radioisotopes such as I-125, I-131 and Tc-99m. There are 10 LINACs, 27 X-ray medicines, 61 radioisotope devices for Co-60 and Cs-137, and 10 mHDR Ir-192 for therapeutic purposes currently used in Indonesia and some Ra-226 in storage. Any activity related to the application of nuclear energy is required to be conducted in a manner which observes safety and security. According to the legal requirements, each user has to employ at least one radiation safety officer. To improve the control of the application of radiation sources and radioactive material in the country, BAPETEN introduced some new approaches to the users, including regular dialogues with radiation safety officers and the management of the users, requalification for radiation protection officers twice in five

  10. Radiation detection and measurement concepts, methods and devices

    CERN Document Server

    McGregor, Douglas

    2019-01-01

    This text on radiation detection and measurement is a response to numerous requests expressed by students at various universities, in which the most popularly used books do not provide adequate background material, nor explain matters in understandable terms. This work provides a modern overview of radiation detection devices and radiation measurement methods. The topics selected in the book have been selected on the basis of the author’s many years of experience designing radiation detectors and teaching radiation detection and measurement in a classroom environment.

  11. Improvement of a device for region radiation survey

    International Nuclear Information System (INIS)

    Poltinnikov, S.A.

    1978-01-01

    The electromechnanical device based on coding the turning angle of an automobile wheel by the number of electric pulses controlling the step motor of a film gate of gamma radiometer is proposed. The device is intended for automatizing recordings of gamma-radiation levels depending on a certain distance in a given terrain. The device has been tested at car speeds from 10 to 80 km/hr

  12. Radiation effects on semiconductor devices in high energy heavy ion accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Belousov, Anton

    2014-10-20

    Radiation effects on semiconductor devices in GSI Helmholtz Center for Heavy Ion Research are becoming more and more significant with the increase of beam intensity due to upgrades. Moreover a new accelerator is being constructed on the basis of GSI within the project of facility for antiproton and ion research (FAIR). Beam intensities will be increased by factor of 100 and energies by factor of 10. Radiation fields in the vicinity of beam lines will increase more than 2 orders of magnitude and so will the effects on semiconductor devices. It is necessary to carry out a study of radiation effects on semiconductor devices considering specific properties of radiation typical for high energy heavy ion accelerators. Radiation effects on electronics in accelerator environment may be divided into two categories: short-term temporary effects and long-term permanent degradation. Both may become critical for proper operation of some electronic devices. This study is focused on radiation damage to CCD cameras in radiation environment of heavy ion accelerator. Series of experiments with irradiation of devices under test (DUTs) by secondary particles produced during ion beam losses were done for this study. Monte Carlo calculations were performed to simulate the experiment conditions and conditions expected in future accelerator. Corresponding comparisons and conclusions were done. Another device typical for accelerator facilities - industrial Ethernet switch was tested in similar conditions during this study. Series of direct irradiations of CCD and MOS transistors with heavy ion beams were done as well. Typical energies of the primary ion beams were 0.5-1 GeV/u. Ion species: from Na to U. Intensities of the beam up to 10{sup 9} ions/spill with spill length of 200-300 ns. Criteria of reliability and lifetime of DUTs in specific radiation conditions were formulated, basing on experimental results of the study. Predictions of electronic device reliability and lifetime were

  13. Radiation damage assessment of Nb tunnel junction devices

    International Nuclear Information System (INIS)

    King, S.E.; Magno, R.; Maisch, W.G.

    1991-01-01

    This paper reports on the radiation hardness of a new technology using Josephson junctions that was explored by an irradiation using a fluence of 7.6 x 10 14 protons/cm 2 at an energy of 63 MeV from the U.C. Davis cyclotron. In what the authors believe is the first radiation assessment of Nb/Al 2 O 3 /Nb devices, the permanent damage in these devices was investigated. No permanent changes in the I-V characteristics of the junctions were observed indicating no significant level of material defects have occurred at this level of irradiation

  14. Characteristics of withstanding radiation damage of InP crystals and devices

    International Nuclear Information System (INIS)

    Yamaguchi, Masafumi; Ando, Koshi

    1988-01-01

    Recently, the authors discovered that the characteristics of with standing radiation damage of InP crystals and devices (solar cells) are superior to those of Si and GaAs crystals and devices. Also the restoration phenomena at room temperature of radiation deterioration and the accelerated anneal phenomena by light irradiation and the injection of other minority, carriers in InP system devices were found. Such excellent characteristics suggested that InP devices are promising for the use in space. In this paper, taking an example of solar cells, the radiation resistance characteristics and their mechanism of InP crystals and devices are reported, based on the results of analysis by deep level transient spectroscopy and others. In InP solar cells, the high efficiency of photoelectric conversion was maintained even in the high dose irradiation of 1 MeV electron beam. As the carrier concentration in InP crystals is higher, they are stronger against radiation. With the increase of carrier concentration, the rate of anneal of radiation deterioration at room temperature increased. The accelerated anneal effect by minority carrier injection was remarkable in n + -p junction cells. The excellent characteristics of InP crystals are due to the formation of Frenkel defects of P and their instability. (K.I.)

  15. An image scanning device using radiating energy

    International Nuclear Information System (INIS)

    Jacob, Daniel.

    1976-01-01

    Said invention relates to an image scanning device using radiating energy. More particularly, it relates to a device for generating a scanning beam of rectangular cross section from a γ or X-ray source. Said invention can be applied to radiographic units of the 'microdose' type used by airline staffs and others for the fast efficient inspection of luggage and parcels in view of detecting hidden things [fr

  16. Medical device for applying therapeutic radiation

    International Nuclear Information System (INIS)

    Tokita, K.M.; Haller, B.L.

    1986-01-01

    A device is described for applying therapeutic radiation from a preselected radiation source to a predetermined portion of a body comprising, in combination: a body member having: an external peripheral surface; a first end surface; and a second end surface spaced from the first end surface; the body member further comprising: at least first internal walls defining a first radiation source receiving channel means spaced a preselected distance from the peripheral surface, and having: a first portion extending from the second end surface to regions adjacent the first end surface; and a second portion extending from the first portion at the first end surface to the second end surface; and, the channel means communicating with regions external the body member at the second surface whereby the radiation source of a preselected intensity inserted at least along a preselected portion of the channel means is applied to the predetermined area of the body requiring therapeutic radiation treatment

  17. Operation control device under radiation exposure

    International Nuclear Information System (INIS)

    Kimura, Kiichi; Murakami, Toichi.

    1994-01-01

    The device of the present invention performs smooth progress of operation by remote control for a plurality of operations in periodical inspections in controlled areas of a nuclear power plant, thereby reducing the operator's exposure dose. Namely, the device monitors the progressing state of the operation by displaying the progress of operation on a CRT of a centralized control device present in a low dose area remote from an operation field through an ITV camera disposed in the vicinity of the operation field. Further, operation sequence and operation instruction procedures previously inputted in the device are indicated to the operation field through an operation instruction outputting device (field CRT) in accordance with the progress of the operation steps. On the other hand, the operation progress can be aided by inputting information from the operation field such as start or completion of the operation steps. Further, the device of the present invention can monitor the change of operation circumstances and exposure dose of operators based on the information from a radiation dose measuring device disposed in the operation circumstance and to individual operators. (I.S.)

  18. Apparatus for minimizing radiation exposure and improving resolution in radiation imaging devices

    International Nuclear Information System (INIS)

    Ashe, J.B.; Williams, G.H.; Sypal, K.L.

    1978-01-01

    A collimator is disclosed for minimizing radiation exposure and improving resolution in radiation imaging devices. The collimator provides a penetrating beam of radiation from a source thereof, which beam is substantially non-diverging in at least one direction. In the preferred embodiment, the collimator comprises an elongated sandwich assembly of a plurality of layers of material exhibiting relatively high radiation attenuation characteristics, which attenuating layers are spaced apart and separated from one another by interleaved layers of material exhibiting relatively low radiation attenuation characteristics. The sandwich assembly is adapted for lengthwise disposition and orientation between a radiation source and a target or receiver such that the attenuating layers are parallel to the desired direction of the beam with the interleaved spacing layers providing direct paths for the radiation

  19. Control device intended for a gamma radiation measuring instrument

    International Nuclear Information System (INIS)

    1976-01-01

    This invention concerns a monitoring device for a gamma radiation measuring instrument or radiation meter, in which the radiation to be measured brings about, inter alia, the ionisation of a gas and the generation of current pulses. The dial of this meter is generally calibrated in roentgens per hour, i.e. in radiation rate units. This instrument of very simple design is remarkable for its operating reliability. Preferably placed at the inlet to a radioactive area, it enables every user of a ratemeter to check, over the entire measuring range of this instrument, its proper operation prior to entering the area. To this effect, the monitoring device in question has a thick wall lead castle, having an internal cavity in which is mounted a radioactive source delivering a gamma radiation with given constant characteristics, through a measurement window closed by a calibrated plug. Lead doors articulated on the castle can be superimposed on this window to bring about a given attenuation of the radiation coming from the source and delivered to the exterior of the castle [fr

  20. Radiation Characterization of Commercial GaN Devices

    Science.gov (United States)

    Harris, Richard D.; Scheick, Leif Z.; Hoffman, James P.; Thrivikraman, Tushar; Jenabi, Masud; Gim, Yonggyu; Miyahira, Tetsuo

    2011-01-01

    Radiative feedback from primordial protostars and final mass of the first star Commercially available devices fabricated from GaN are beginning to appear from a number of different suppliers. Based on previous materials and prototype device studies, it is expected that these commercial devices will be quite tolerant to the types of radiation encountered in space. This expectation needs to be verified and the study described herein was undertaken for that purpose. All of the parts discussed in this report are readily available commercially. The parts chosen for study are all targeted for RF applications. Three different studies were performed: 1) a preliminary DDD/TID test of a variety of part types was performed by irradiating with 50 MeV protons, 2) a detailed DDD/TID study of one particular part type was performed by irradiating with 50 MeV protons, and 3) a SEB/SEGR test was performed on a variety of part types by irradiating with heavy ions. No significant degradation was observed in the tests performed in this study.

  1. Judicial facts on licensing and supervisory procedures concerning radiation protection law

    International Nuclear Information System (INIS)

    Rosenhaum, O.

    1976-01-01

    Some statistical studies on the present licensing and supervision procedures are discussed, viz. on 1) owner of a licence accord. to sect. 3 and 4 of the 1st Radiation Protection Ordinance; 2) special licences according to section 1 of the Radiation Protection Ordinance for the release of radioactive materials in air and water (required in a very few cases only); 3) violations of the regulations were not of a severe nature (mostly from industry). The author condludes that the present regulations proved to be satisfactory. Minor corrections relating to licence-free handling, restriction of the requirements for a licence as well as to prohibition of illegal use of the radiation warning sign are desired. (HP) [de

  2. EMERGENCY RADIATION SURVEY DEVICE ONBOARD THE UAV

    Directory of Open Access Journals (Sweden)

    S. Bogatov

    2013-08-01

    Full Text Available Radiation survey device (RSD on the base of unmanned aerial vehicle (UAV was developed as an equipment of rescue forces for radiation situation reconnaissance in case of emergency. RSD is multi range radiometer with spectrometer functions capable to work within gamma ray fields of dose rate 10–7 – 10–1 Sievert per hour. UAV md4-1000 (Microdrones GmbH, Germany was selected as the RSD carrier as a reliable vehicle with appropriate properties. Short description of RSD, UAV and developed software features as well as sensitivity assessments for different radiation sources are presented.

  3. Systems reliability analyses and risk analyses for the licencing procedure under atomic law

    International Nuclear Information System (INIS)

    Berning, A.; Spindler, H.

    1983-01-01

    For the licencing procedure under atomic law in accordance with Article 7 AtG, the nuclear power plant as a whole needs to be assessed, plus the reliability of systems and plant components that are essential to safety are to be determined with probabilistic methods. This requirement is the consequence of safety criteria for nuclear power plants issued by the Home Department (BMI). Systems reliability studies and risk analyses used in licencing procedures under atomic law are identified. The stress is on licencing decisions, mainly for PWR-type reactors. Reactor Safety Commission (RSK) guidelines, examples of reasoning in legal proceedings and arguments put forth by objectors are also dealt with. Correlations are shown between reliability analyses made by experts and licencing decisions by means of examples. (orig./HP) [de

  4. Bill C-5, an act to amend the radiation emitting devices act

    International Nuclear Information System (INIS)

    1984-01-01

    This Act, entitled Bill C-5, allows for a series of amendments to the Radiation Emitting Devices Act. The amendments relate to regulations concerned with the sale, lease or import, labelling, advertising, packaging, safety standards and inspection of radiation emitting devices

  5. An analysis of radiation effects on electronics and soi-mos devices as an alternative

    International Nuclear Information System (INIS)

    Ikraiam, F. A.

    2013-01-01

    The effects of radiation on semiconductors and electronic components are analyzed. The performance of such circuitry depends upon the reliability of electronic devices where electronic components will be unavoidably exposed to radiation. This exposure can be detrimental or even fatal to the expected function of the devices. Single event effects (SEE), in particular, which lead to sudden device or system failure and total dose effects can reduce the lifetime of electronic devices in such systems are discussed. Silicon-on-insulator (SOI) technology is introduced as an alternative for radiation-hardened devices. I-V Characteristics Curves for SOI-MOS devices subjected to a different total radiation doses are illustrated. In addition, properties of some semiconductor materials such as diamond, diamond-like carbon films, SiC, GaP, and AlGaN/GaN are compared with those of SOI devices. The recognition of the potential usefulness of SOI-MOS semiconductor materials for harsh environments is discussed. A summary of radiation effects, impacts and mitigation techniques is also presented. (authors)

  6. Social licence, corporate social responsibility and coal seam gas: framing the new political dynamics of contestation

    International Nuclear Information System (INIS)

    Curran, Giorel

    2017-01-01

    This paper explores the contestation dynamics between the unconventional gas mining sector and its challengers through the prism of the social licence to operate. Social licence is a dominant narrative in the mining sector today and as a signifier of the sector's CSR credentials, the term is an influential one. Its capacity to confer project legitimacy, and hence avoid the risks of community opposition, helps explain why most companies seek to gain one. Today both gas proponents and opponents talk the language of social licence: the former to defend their projects, the latter to challenge them. Yet, beyond rhetoric, the precise meaning of social licence remains elusive. This paper uses a case study of community opposition to primarily coal seam gas projects in an eastern Australian region to explore how the absence of a precise meaning for social licence has created a strategic opportunity space for the industry's opponents to invest social licence with a potent democracy frame. This democracy framing has proved particularly effective as a contestation tool and helps explain the outcomes in this case. - Highlights: • Unconventional gas exploration and mining is becoming increasingly contested. • A key way of managing this contestation is through the social licence to operate. • Both proponents and opponents of gas mining use social licence strategically. • Social licence has become increasingly politicised. • A democratic frame assists the effectiveness of contestation.

  7. Communication and Public Information in Development and Maintenance of Radiation Safety

    International Nuclear Information System (INIS)

    Huurto, L.

    2003-01-01

    The natural source of Non-Ionizing radiation (NIR) in our environment is the sun. Artificial NIR is widely used in medical and industrial applications and also in households. The most important medical NIR applications are phototherapy, surgical lasers and magnetic resonance imaging. In industry NIR is applied in radio frequency heaters and laser printing. NIR has applications even in entertainment and cosmetics: High power lasers are used in light shows and sun beds emit artificial ultraviolet radiation (UVR) for tanning. From the safety point of view the field is indeed very wide from harmless and common items to devices which can cause acute health hazards. The use of non-ionizing radiation needs neither any safety licence nor other kind of authorisation. The users of NIR devices varies from professionals in health care or lighting technology to those who only use them as a sideline in their main work like beauticians. Also laypersons use various NIR devices like microwave ovens, laser pointers and mobile phones. Many NIR devices are used in applications where the user does not have the knowledge to understand the health risks associated with the device. Thus the only way is to educate the users by communication and public information. (orig.)

  8. Decontamination method and device for radiation contaminated product

    International Nuclear Information System (INIS)

    Morikawa, Kenji; Ohinata, Hiroshi; Omata, Kazuo; Sato, Toshihiko; Nakajima, Yoshihiko; Ichikawa, Seigo.

    1996-01-01

    In the present invention, radiation contaminated products generated during shot peening are decontaminated by a chelating agent, and the chelating agent is removed from the radiation contaminated products. Then the temperature of the radiation contaminated products is elevated by hot blowing at a temperature higher than a boiling point of the solvent. Then, a solvent is added to the radiation contaminated products and the solvent is evaporated abruptly. The solution of the chelating agent remained while being deposited thereto is removed by evaporation to remove it from the radiation contaminated products together with the solvent. With such procedures, all of the decontamination steps can be completed in one device without requiring a large space or not moving the radiation contaminated products on every step. (T.M.)

  9. Radiation effects and soft errors in integrated circuits and electronic devices

    CERN Document Server

    Fleetwood, D M

    2004-01-01

    This book provides a detailed treatment of radiation effects in electronic devices, including effects at the material, device, and circuit levels. The emphasis is on transient effects caused by single ionizing particles (single-event effects and soft errors) and effects produced by the cumulative energy deposited by the radiation (total ionizing dose effects). Bipolar (Si and SiGe), metal-oxide-semiconductor (MOS), and compound semiconductor technologies are discussed. In addition to considering the specific issues associated with high-performance devices and technologies, the book includes th

  10. The discourse of "social licence to operate": case study of the Australian wind industry

    Directory of Open Access Journals (Sweden)

    Nina L. Hall

    2014-12-01

    Full Text Available Social Licence to Operate is a concept from the mining industry that reflects the ongoing acceptance or approval for a development granted by local stakeholders. It is now being applied by wind farm developers. Using the Australian wind industry as a case study, this discourse analysis examined how Social Licence to Operate is perceived and operationalised, and the key themes in this conceptual and applied discourse. Discourse analysis acknowledges that language choices are not accidental and discourse reflects power relationships. The wind industry representatives interviewed considered power over the Social Licence to Operate was shared with community stakeholders. They recognised the stakeholders' power to delay or prevent projects, but rejected the notion that every stakeholder group should have veto power. Social Licence to Operate is seen by the wind industry through a business-oriented perspective, with an emphasis on business risk, and they describe the opposition to wind farms by invoking a metaphor of "battle". The industry respondents described Social Licence to Operate as incorporating the values of trust, transparency and participation—which all contribute to creating "authentic" relationships. These findings can inform Social Licence to Operate research, engagement practices, and also encourage reflection by industry representatives on their implicit intentions for stakeholder engagement.

  11. Adjustable radiation protection device of the fluoroscope DG 10

    International Nuclear Information System (INIS)

    Hoermann, D.

    1980-01-01

    In cooperation with the 'VEB Transformatoren- und Roentgenwerk Hermann Matern', Dresden, an adjustable radiation protection device has been developed. This supplementary equipment for fluoroscopes ensures a sufficient protection of the gonads against undesirable X radiation, can be handled easily and does not annoy patients, esp. children

  12. Reading device of a radiation image contained in a radioluminescent screen and tomography device containing it

    International Nuclear Information System (INIS)

    Allemand, R.; Cuzin, M.; Parot, P.

    1984-01-01

    The present invention is aimed at improving the random access time to a stimulable radioluminescent screen point (and consequently the reading time of the screen image); it is noticeably useful for longitudinal tomography. The reading device contains a source emitting a stimulation radiation beam towards the stimulable radioluminescent screen, a control mean of the stimulation radiation beam and a deflection mean which allows the beam to scan the screen surface. The device is characterized by the use of a very fast acousto-optical type deflection mean [fr

  13. Charge-coupled devices as positron sensitive detectors of x-radiation

    International Nuclear Information System (INIS)

    Volkov, G.S.; Zazhivikhin, V.V.; Zajtsev, V.I.; Mishevskij, V.O.

    1996-01-01

    Results of theoretical and experimental studies on the sensitivity and spatial resolution of devices with a charge link (CLD) within the X-radiation energy range are described. The areas of the device application are considered

  14. Review of radiation effects on ReRAM devices and technology

    Science.gov (United States)

    Gonzalez-Velo, Yago; Barnaby, Hugh J.; Kozicki, Michael N.

    2017-08-01

    A review of the ionizing radiation effects on resistive random access memory (ReRAM) technology and devices is presented in this article. The review focuses on vertical devices exhibiting bipolar resistance switching, devices that have already exhibited interesting properties and characteristics for memory applications and, in particular, for non-volatile memory applications. Non-volatile memories are important devices for any type of electronic and embedded system, as they are for space applications. In such applications, specific environmental issues related to the existence of cosmic rays and Van Allen radiation belts around the Earth contribute to specific failure mechanisms related to the energy deposition induced by such ionizing radiation. Such effects are important in non-volatile memory as the current leading technology, i.e. flash-based technology, is sensitive to the total ionizing dose (TID) and single-event effects. New technologies such as ReRAM, if competing with or complementing the existing non-volatile area of memories from the point of view of performance, also have to exhibit great reliability for use in radiation environments such as space. This has driven research on the radiation effects of such ReRAM technology, on both the conductive-bridge RAM as well as the valence-change memories, or OxRAM variants of the technology. Initial characterizations of ReRAM technology showed a high degree of resilience to TID, developing researchers’ interest in characterizing such resilience as well as investigating the cause of such behavior. The state of the art of such research is reviewed in this article.

  15. Radiation as a microbiological contamination control of drugs, cosmetics and medical devices

    International Nuclear Information System (INIS)

    Ishizeki, Chuichi

    1985-01-01

    This paper deals with current status of radiation sterilization or disinfection of drugs, cosmetics, their materials, and medical devices, and with quality control as a tool for securing microbiological safety, especially current status of sterilization tests. Ointment containing tetracyclin, steroid hormones, gelatin, and enzymes are presented as drug samples to be irradiated, and explanations for radiation sterilization of these drugs are provided. An outline of the application of radiation in cosmetics and medical devices is given. Issues are also provided from the viewpoint of safey and effectiveness of radiation sterilization. (Namekawa, K.)

  16. Evaluation of stray radiofrequency radiation emitted by electrosurgical devices

    International Nuclear Information System (INIS)

    De Marco, M; Maggi, S

    2006-01-01

    Electrosurgery refers to the passage of a high-frequency, high-voltage electrical current through the body to achieve the desired surgical effects. At the same time, these procedures are accompanied by a general increase of the electromagnetic field in an operating room that may expose both patients and personnel to relatively high levels of radiofrequency radiation. In the first part of this study, we have taken into account the radiation emitted by different monopolar electrosurgical devices, evaluating the electromagnetic field strength delivered by an electrosurgical handle and straying from units and other electrosurgical accessories. As a summary, in the worst case a surgeon's hands are exposed to a continuous and pulsed RF wave whose magnetic field strength is 0.75 A m -1 (E-field 400 V m -1 ). Occasionally stray radiation may exceed ICNIRP's occupational exposure guidelines, especially close to the patient return plate. In the second part of this paper, we have analysed areas of particular concern to prevent electromagnetic interference with some life-support devices (ventilators and electrocardiographic devices), which have failed to operate correctly. Most clinically relevant interference occurred when an electrosurgery device was used within 0.3 m of medical equipment. In the appendix, we suggest some practical recommendations intended to minimize the potential for electromagnetic hazards due to therapeutic application of RF energy

  17. RADIATION PERFORMANCE OF GAN AND INAS/GAAS QUANTUM DOT BASED DEVICES SUBJECTED TO NEUTRON RADIATION

    Directory of Open Access Journals (Sweden)

    Dhiyauddin Ahmad Fauzi

    2017-05-01

    Full Text Available In addition to their useful optoelectronics functions, gallium nitride (GaN and quantum dots (QDs based structures are also known for their radiation hardness properties. With demands on such semiconductor material structures, it is important to investigate the differences in reliability and radiation hardness properties of these two devices. For this purpose, three sets of GaN light-emitting diode (LED and InAs/GaAs dot-in-a well (DWELL samples were irradiated with thermal neutron of fluence ranging from 3×1013 to 6×1014 neutron/cm2 in PUSPATI TRIGA research reactor. The radiation performances for each device were evaluated based on the current-voltage (I-V and capacitance-voltage (C-V electrical characterisation method. Results suggested that the GaN based sample is less susceptible to electrical changes due to the thermal neutron radiation effects compared to the QD based sample.

  18. Licence template for mobile handling and storage of radioactive substances for the nondestructive testing of materials; Mustergenehmigung zur ortsveraenderlichen Verwendung und Lagerung radioaktiver Stoffe im Rahmen der zerstoerungsfreien Materialpruefung

    Energy Technology Data Exchange (ETDEWEB)

    Lange, A. [Niedersaechsisches Ministerium fuer Umwelt, Energie und Klimaschutz (Germany); Schumann, J. [Landesamt fuer Arbeitsschutz, Gesundheitsschutz und technische Sicherheit, Berlin (Germany); Huhn, W.

    2016-07-01

    The Technical Committee ''Radiation Protection'' (Fachausschuss ''Strahlenschutz'') and the Laender Committee ''X-ray ordinance'' (Laenderausschuss ''Roentgenverordnung'') have appointed a working group for the formulation of licence templates for the nationwide use of X-ray equipment or handling of radioactive substances. To date, the following licence templates have been adopted: - Mobile operation of X-ray equipment under technical radiography to the coarse structural analysis in material testing; - Mobile operation of a handheld X-ray fluorescence system; - Mobile operation of a flash X-ray system; - Operation of an X-ray system for teleradiology The licence template ''Mobile handling and storage of radioactive substances for the nondestructive testing of materials'' is scheduled for publication. The licence template ''Practices in external facilities and installations'' is currently being revised. The licence template ''Mobile handling and storage of radioactive substances for the nondestructive testing of materials'' is used as an example to demonstrate the legal framework and the results of the working group.

  19. Radiation practices. Annual report 2009

    International Nuclear Information System (INIS)

    Rantanen, E.

    2010-08-01

    1 742 safety licences for the use of radiation were current at the end of 2009. 1 820 responsible parties were engaged in notifiable licence-exempt dental X-ray activities. Use of radiation was controlled through regular inspections performed at places of use, test packages sent by post to dental X-ray facilities and maintenance of the Dose Register. Radiation safety guides were also published and research was conducted in support of regulatory control. The Radiation and Nuclear Safety Authority (STUK) conducted 414 inspections of licensed practices in 2009. 392 repair orders and recommendations were issued. A total of nearly 11 600 workers were subject to individual monitoring in 2009. Just under 160 000 dose entries were made in the Dose Register maintained by STUK. Regulatory control of natural radiation focused on radon at workplaces and exposure of aircrews to cosmic radiation. 108 workplaces including a total of 219 work areas were subject to radon monitoring during 2009. 3655 cockpit and cabin crew members were monitored for exposure to cosmic radiation. STUK took part in three major ionizing radiation research projects. An IAEA research project tested IAEA/WHO diagnostic dosimetry guidelines. The accuracy and reliability of internal and external radiotherapy dosimetric methods in modern radiotherapy technology was studied as part of a European metrology research programme. In metrological activities the calibration procedure for radiotherapy accelerator electron beam dosemeters was modified by changing from meter calibration in hospitals to laboratory calibration. Some irradiation appliances were also replaced. Calibration services continued as in previous years. Regulatory control of the use of non-ionizing radiation in 2009 focused particularly on mobile phones, sunbeds and lasers. Fifteen mobile phone types were tested in market surveillance of wireless communication devices. 19 sunbed facilities were inspected and ten laser display inspections were

  20. Radiation practices. Annual report 2010

    Energy Technology Data Exchange (ETDEWEB)

    Rantanen, E. (ed.)

    2011-07-01

    1760 safety licences for the use of radiation were current at the end of 2010. 1789 responsible parties were engaged in notifiable licence-exempt dental X-ray activities. Use of radiation was controlled through regular inspections performed at places of use, test packages sent by post to dental X-ray facilities and maintenance of the Dose Register. Radiation safety guides were also published and research was conducted in support of regulatory control. The Radiation and Nuclear Safety Authority (STUK) conducted 384 inspections of licensed practices in 2010. 447 repair orders and recommendations were issued in the course of inspections. A total of nearly 12 100 workers were subject to individual monitoring in 2010. Just under 160 000 dose entries were made in the Dose Register maintained by STUK. Regulatory control of natural radiation focused on radon at workplaces and exposure of aircrews to cosmic radiation. 140 workplaces including a total of 348 work areas were subject to radon monitoring during 2010. 3428 cockpit and cabin crew members were monitored for exposure to cosmic radiation. STUK took part in three major ionizing radiation research projects. An IAEA research project tested diagnostic dosimetry guidelines. The accuracy and reliability of internal and external radiotherapy dosimetric methods in modern radiotherapy technology were studied as part of a European metrology research programme. In metrological activities the dosemeter calibration procedure for radiotherapy accelerator electron beams was modified by changing from meter calibrations in hospitals to laboratory calibrations. Some irradiation appliances were also replaced. Calibration services continued as in previous years. Regulatory control of the use of non-ionizing radiation in 2010 focused particularly on mobile phones, sunbeds and lasers. 16 sunbed facilities were inspected and 8 on-site laser display inspections were performed. Ten mobile phone types were tested in market surveillance of

  1. Radiation effects in LDD MOS devices

    International Nuclear Information System (INIS)

    Woodruff, R.L.; Adams, J.R.

    1987-01-01

    The purpose of this work is to investigate the response of lightly doped drain (LDD) n-channel transistors to ionizing radiation. Transistors were fabricated with conventional (non-LDD) and lightly doped drain (LDD) structures using both standard (non-hardened) and radiation hardened gate oxides. Characterization of the transistors began with a correlation of the total-dose effects due to 10 keV x-rays with Co-60 gamma rays. The authors find that for the gate oxides and transistor structures investigated in this work, 10 keV x-rays produce more fixed-charge guild-up in the gate oxide, and more interface charge than do Co-60 gamma rays. They determined that the radiation response of LDD transistors is similar to that of conventional (non-LDD) transistors. In addition, both standard and radiation-hardened transistors subjected to hot carrier stress before irradiation show a similar radiation response. After exposure to 1.0 x 10 6 rads(Si), non-hardened transistors show increased susceptibility to hot-carrier graduation, while the radiation-hardened transistors exhibit similar hot-carrier degradation to non-irradiated devices. The authors have demonstrated a fully-integrated radiation hardened process tht is solid to 1.0 x 10 6 rads(Si), and shows promise for achieving 1.0 x 10 7 rad(Si) total-dose capability

  2. Device for converting electromagnetic radiation energy into electrical energy and method of manufacturing such a device

    NARCIS (Netherlands)

    2007-01-01

    Device (10) for converting electromagnetic radiation energy into electrical energy, comprising at least a photovoltaic element (11) with a radiation-sensitive surface, wherein a covering layer (12) of a material comprising a silicon compound, to which a rare earth element has been added, is present

  3. Licences issued under environmental law in international private and procedural law

    International Nuclear Information System (INIS)

    Kohler, C.

    1991-01-01

    The paper examines the following points in connection with claims for compensation and to protection against abridgement of legal rights involving foreign persons or legal entities: - The limits set by international law to national judicial authority, - the international competence of courts, i.e. under which conditions national courts can have jurisdiction in cases involving foreign persons or legal entities, - the applicable law, and finally the question of - under which conditions judgements of the judiciary state must be observed abroad and foreign judgements must be observed in the judiciary state, i.e. acknowledged and executed. In the case of impairments of the environment the particular problem arises of the effect of licences issued under public law. The paper discusses the former practice, the qualification, the ways of observing the legal rules governing licences and their effects, and the question as to the unconditional enforcement of national licences against foreign affected parties. (HSCH) [de

  4. Radioactivity concentration measuring device for radiation waste containing vessel

    International Nuclear Information System (INIS)

    Goto, Tetsuo.

    1994-01-01

    The device of the present invention can precisely and accurately measure a radioactive concentration of radioactive wastes irrespective of the radioactivity concentration distribution. Namely, a Ge detector having a collimator and a plurality of radiation detectors are placed at the outside of the radioactive waste containing vessel in such a way that it can rotate and move vertically relative to the vessel. The plurality of radiation detectors detect radiation coefficient signals at an assumed segment unit of a predetermined length in vertical direction and for every predetermined angle unit in the rotational direction. A weight measuring device determines the weight of the vessel. A computer calculates an average density of radioactivity for the region filled with radioactivity based on the determined net weight and radiation coefficient signals assuming that the volume of the radioactivity is constant. In addition, the computer calculates the amount of radioactivity in the assumed segment by conducting γ -ray absorption compensation calculation for the material in the vessel. Each of the amount of radioactivity is integrated to determine the amount of radioactivity in the vessel. (I.S.)

  5. The radiation protective devices for interventional procedures using computed tomography

    International Nuclear Information System (INIS)

    Iida, Hiroji; Chabatake, Mitsuhiro; Shimizu, Mitsuru; Tamura, Sakio

    2002-01-01

    A scattered dose and a surface dose from phantom measurements during interventional procedures with computed tomography (IVR-CT) were evaluated. To reduce the personnel exposure in IVR-CT, the new protective devices were developed and its effect evaluated. Two radiation protection devices were experimentally made using a lead vinyl sheet with lead equivalent 0.125 mmPb. The first device is a lead curtain which shields the space of CT-gantry and phantom for the CT examination. The second device is a lead drape which shields on the phantom surface adjacent to the scanning plane for the CT-fluoroscopy. Scattered dose and phantom surface dose were measured with an abdominal phantom during Cine-CT (130 kV, 150 mA, 5 seconds, 10 mm section thickness). They were measured by using ionization chamber dosimeter. They were measured with and without a lead curtain and a lead drape. Scattered dose rate was measured at distance of 50-150 cm from the scanning plane. And, surface dose was measured at distance of 4-21 cm from the scanning plane on the phantom. On operator's standing position, scattered dose rates were from 8.4 to 11.6 μGy/sec at CT examination. The lead curtain and the lead drape reduced scattered dose rate at distance of 50 cm from the scanning plane by 66% and 58.3% respectively. Surface dose rate were 118 μGy/sec at distance of 5 cm from the scanning plane at CT-fluoroscopy. The lead drape reduced the surface dose by 60.5%. High scattered exposure to personnel may occur during interventional procedures using CT. They were considerably reduced during CT-arteriography by attaching the lead curtain in CT equipment. And they were substantially reduced during CT-fluoroscopy by placing the lead drape adjacent to the scanning plane, in addition, operator's hand would be protected from unnecessary radiation scattered by phantom. It was suggested that the scattered exposure to personnel could be sufficiently reduced by using radiation protection devices in IVR-CT. The

  6. Response of asymmetric carbon nanotube network devices to sub-terahertz and terahertz radiation

    International Nuclear Information System (INIS)

    Gayduchenko, I.; Kardakova, A.; Voronov, B.; Finkel, M.; Fedorov, G.; Jiménez, D.; Morozov, S.; Presniakov, M.; Goltsman, G.

    2015-01-01

    Demand for efficient terahertz radiation detectors resulted in intensive study of the asymmetric carbon nanostructures as a possible solution for that problem. It was maintained that photothermoelectric effect under certain conditions results in strong response of such devices to terahertz radiation even at room temperature. In this work, we investigate different mechanisms underlying the response of asymmetric carbon nanotube (CNT) based devices to sub-terahertz and terahertz radiation. Our structures are formed with CNT networks instead of individual CNTs so that effects probed are more generic and not caused by peculiarities of an individual nanoscale object. We conclude that the DC voltage response observed in our structures is not only thermal in origin. So called diode-type response caused by asymmetry of the device IV characteristic turns out to be dominant at room temperature. Quantitative analysis provides further routes for the optimization of the device configuration, which may result in appearance of novel terahertz radiation detectors

  7. Static validation of licence conformance policies

    DEFF Research Database (Denmark)

    Hansen, Rene Rydhof; Nielson, Flemming; Nielson, Hanne Riis

    2008-01-01

    Policy conformance is a security property gaining importance due to commercial interest like Digital Rights Management. It is well known that static analysis can be used to validate a number of more classical security policies, such as discretionary and mandatory access control policies, as well...... as communication protocols using symmetric and asymmetric cryptography. In this work we show how to develop a Flow Logic for validating the conformance of client software with respect to a licence conformance policy. Our approach is sufficiently flexible that it extends to fully open systems that can admit new...

  8. Study of radiation effects on semiconductor devices

    International Nuclear Information System (INIS)

    Kuboyama, Satoshi; Shindou, Hiroyuki; Ikeda, Naomi; Iwata, Yoshiyuki; Murakami, Takeshi

    2004-01-01

    Fine structure of the recent semiconductor devices has made them more sensitive to the space radiation environment with trapped high-energy protons and heavy ions. A new failure mode caused by bulk damage had been reported on such devices with small structure, and its effect on commercial synchronous dynamic random access memory (SDRAMs) was analyzed from the irradiation test results performed at Heavy ion Medical Accelerator in Chiba (HIMAC). Single event upset (SEU) data of static random access memory (SRAMs) were also collected to establish the method of estimating the proton-induced SEU rate from the results of heavy ion irradiation tests. (authors)

  9. The safety of radiation sources and radioactive materials in China

    International Nuclear Information System (INIS)

    Liu, H.

    2001-01-01

    The report describes the present infrastructure for the safety of radiation sources in China, where applications of radiation sources have become more and more widespread in the past years. In particular, it refers to the main functions of the National Nuclear Safety Administration of the State Environmental Protection Administration (SEPA), which is acting as the regulatory body for nuclear and radiation safety at nuclear installations, the Ministry of Public Health which issues licences for the use of radiation sources, and the Ministry of Public Security, which deals with the security of radiation sources. The report also refers to the main requirements of the existing regulatory system for radiation safety, i.e. the basic dose limits for radiation workers and the public, the licensing system for nuclear installations and for radioisotope-based and other irradiation devices, and the environmental impact assessment system. Information on the nationwide survey of radiation sources carried out by SEPA in 1991 is provided, and on some accidents that occurred in China due to loss of control of radiation sources and errors in the operation of irradiation facilities. (author)

  10. Angola: new fields, new licences, and hopes of peace

    International Nuclear Information System (INIS)

    Quinlan, Martin.

    1994-01-01

    This article focuses on petroleum production in Angola. Offshore and onshore exploration rights are listed, and Chevron's offshore Cabinda licence, increasing output from Elf's Block 3, problems experience by Texaco's Block 2 fields, and licensing successes are discussed. (UK)

  11. Regulations of 1 September 1978 on the issue of licences to operators of nuclear facilities

    International Nuclear Information System (INIS)

    1978-01-01

    These regulations were published in the Turkish Official Gazette of 1 September 1978. Their purpose is to regulate the granting of licences to authorised technicians and approved operators in accordance with Decree No. 7/9141 of 1975. They lay down the procedure for applying for a licence, the conditions to be complied with, the documents to be supplied and the exemptions from such licensing requirements. Finally, they establish the period of validity of the licences and the procedures for their renewal. (NEA) [fr

  12. Radiation from ingested wireless devices in bio-medical telemetry bands

    OpenAIRE

    Chirwa, L.C.; Roy, S.; Cumming, D.R.S.

    2003-01-01

    The performance of wireless devices, using electrically small antennae, in the human intestine is investigated using the finite difference time domain method in recommended biomedical device telemetry bands. The radiation field intensity was found to depend on position but more strongly on frequency, with a transmission peak at 650 MHz.

  13. Effect on the insulation material of a MOSFET device submitted to a standard diagnostic radiation beam

    International Nuclear Information System (INIS)

    De Magalhaes, C M S; Dos Santos, L A P; Souza, D do N; Maia, A F

    2010-01-01

    MOSFET electronic devices have been used for dosimetry in radiology and radiotherapy. Several communications show that due to the radiation exposure defects appear on the semiconductor crystal lattice. Actually, the structure of a MOSFET consists of three materials: a semiconductor, a metal and an insulator between them. The MOSFET is a quadripolar device with a common terminal: gate-source is the input; drain-source is the output. The gate controls the electrical current passing through semiconductor medium by the field effect because the silicon oxide acts as insulating material. The proposal of this work is to show some radiation effects on the insulator of a MOSFET device. A 6430 Keithley sub-femtoamp SourceMeter was used to verify how the insulating material layer in the structure of the device varies with the radiation exposure. We have used the IEC 61267 standard radiation X-ray beams generated from a Pantak industrial unit in the radiation energy range of computed tomography. This range was chosen because we are using the MOSFET device as radiation detector for dosimetry in computed tomography. The results showed that the behaviour of the electrical current of the device is different in the insulator and semiconductor structures.

  14. Device for the integral measurement of ionizing radiations

    International Nuclear Information System (INIS)

    Micheron, Francois.

    1980-01-01

    This invention relates to devices for the integral determination of ionizing radiations, particularly to the construction of a portable dosemeter. Portable measuring instruments have been suggested in the past, particularly dosemeters in which the discharge of a capacitor under the action of ionizing radiations is measured. Since the charge of a capacitor is not stable owing to dielectric imperfections, these measuring instruments have to be recalibrated at frequent intervals. To overcome this drawback, the invention suggests using the discharge of an electret, electrically charged to a pre-set initial value, under the action of ionizing radiations, as the transducer means of a dosemeter used in conjunction with display or warning systems [fr

  15. Radiation hardness and qualification of semiconductor electronic devices for nuclear reactors

    International Nuclear Information System (INIS)

    Friant, A.; Payat, R.

    1984-05-01

    After a brief review of radiation effects in semiconductors and radiation damage in semiconductor devices, the problems of qualification of electronic equipment to be used in nuclear reactors are compared to those relative to nuclear weapons or space experiments. The conclusion is that data obtained at very high dose rates or under pulsed irradiation in weapons and space programs should not be directly applied to nuclear plant instrumentation. The need for a specific qualification of semiconductor devices appropriate for nuclear reactors is emphasized. Some irradiation studies at IRDI/DEIN (CEN-Saclay) are related [fr

  16. Problematic radiation protective devices for X-ray diagnostics

    International Nuclear Information System (INIS)

    Beck, A.; Nanko, N.; Bruggmoser, G.; Eble, M.

    1988-01-01

    The authors report experimental test results of radiation safety glasses with a lead equivalence of 0.5 mm Pb. The glasses were tested on a phantom, with various radiation projections, for their shielding effect with regard to the eye lens. The protective effect at AP projection was 90%, which corresponds to the data given by the manufacturer. But in most cases of interventional radiology, the examiner's eyes are exposed to lateral radiation, due to the positioning of the monitor. In these cases, reflected radiation at the side of the glasses facing the eye may induce a dose to the lens that can be fourfold the dose received without wearing the glasses, so that wearing these glasses may enhance the hazard. Another protective device tested was lead-coated gloves. The manufacturer promises a protective effect of 50% at 100 kV. The experimental test data, obtained by taking into account technical characteristics of angiographic components, confirm a radiation shielding of about 20%. (orig./HP) [de

  17. Radiation dose measurements of the insertion devices using radiachromic film dosimeters

    International Nuclear Information System (INIS)

    Alderman, J.; Semones, E.; Job, P. K.

    2004-01-01

    The Advanced Photon Source (APS) uses Nd-Fe-B permanent magnets in the insertion devices to produce x-rays for scientific research [1,2]. Earlier investigations have exhibited varying degrees of demagnetization of these magnets [3] due to irradiation from electron beams [4,5,6], 60 Co γ-rays [5], and high-energy neutrons [7,8]. Radiation-induced demagnetization has been observed in the APS insertion devices [9] and was first measured in December of 2001. Partial demagnetization has also been observed in insertion devices at the European Synchrotron Radiation Facility (ESRF) [4,6], where Nd-Fe-B permanent magnets are also used. Growing concern for the lifetime of APS insertion devices, as well as the permanent magnets that will be used in next-generation, high-power light sources, like the FEL [10,11], resulted from the partial demagnetization observations made at both facilities. This concern in relation to radiation-induced demagnetization spurred a long-term project to measure and analyze the absorbed doses received by the APS insertion devices. The project required a reliable photon high-dose dosimetry technique capable of measuring absorbed doses greater than 10 6 rad, which was not readily available at the APS. Through a collaboration with the National Institute of Standards and Technology (NIST), one such technique using radiachromic films was considered, tested, and calibrated at the APS. This consequently led to the implementation of radiachromic film dosimetry for measuring the absorbed doses received by the insertion devices for each of the APS runs

  18. The responsible radiation protection supervisor: Who actually is he? Legal entities under public law and their legal responsibilities pursuant to radiation protection laws

    International Nuclear Information System (INIS)

    Brinkmann, M.

    1998-01-01

    All radiation protection relevant activities subject to licencing or notifying include observation of legally allocated responsibilities. Responsible radiation protection supervisor is the licence owner in person. If the holder is a legal entity, that entity is responsible as such. The executives of the entity exercise the functions of a responsible radiation protection officer, or may delegate them to an authorized deputy. In this case, the yardstick of a possible liability may be changed. The liability of the responsible persons is determined by the general legal regulations. (orig.) [de

  19. Electromagnetic Radiation Efficiency of Body-Implanted Devices

    Science.gov (United States)

    Nikolayev, Denys; Zhadobov, Maxim; Karban, Pavel; Sauleau, Ronan

    2018-02-01

    Autonomous wireless body-implanted devices for biotelemetry, telemedicine, and neural interfacing constitute an emerging technology providing powerful capabilities for medicine and clinical research. We study the through-tissue electromagnetic propagation mechanisms, derive the optimal frequency range, and obtain the maximum achievable efficiency for radiative energy transfer from inside a body to free space. We analyze how polarization affects the efficiency by exciting TM and TE modes using a magnetic dipole and a magnetic current source, respectively. Four problem formulations are considered with increasing complexity and realism of anatomy. The results indicate that the optimal operating frequency f for deep implantation (with a depth d ≳3 cm ) lies in the (108- 109 )-Hz range and can be approximated as f =2.2 ×107/d . For a subcutaneous case (d ≲3 cm ), the surface-wave-induced interference is significant: within the range of peak radiation efficiency (about 2 ×108 to 3 ×109 Hz ), the max-to-min ratio can reach a value of 6.5. For the studied frequency range, 80%-99% of radiation efficiency is lost due to the tissue-air wave-impedance mismatch. Parallel polarization reduces the losses by a few percent; this effect is inversely proportional to the frequency and depth. Considering the implantation depth, the operating frequency, the polarization, and the directivity, we show that about an order-of-magnitude efficiency improvement is achievable compared to existing devices.

  20. Effects of cosmic radiation on devices and embedded systems in aircrafts

    Energy Technology Data Exchange (ETDEWEB)

    Prado, Adriane C.M.; Federico, Claudio A.; Pereira Junior, Evaldo C.F.; Goncalez, Odair L., E-mail: claudiofederico@ieav.cta.br, E-mail: odairlelisgoncalez@gmail.com, E-mail: adriane.acm@hotmail.com, E-mail: evaldocarlosjr@gmail.com [Instituto de Estudos Avancados (IEAV/DCTA), Sao Jose dos Campos, SP (Brazil)

    2013-07-01

    Modern avionics systems use new electronic technologies devices that, due to their high degree of sophistication and miniaturization, are more susceptible to the effects of ionizing radiation, particularly the effect called 'Single Event Effect' (SEE) produced by neutron. Studies regarding the effects of radiation on electronic systems for space applications, such as satellites and orbital stations, have already been in progress for several years. However, tolerance requirements and specific studies, focusing on testing dedicated to avionics, have caused concern and gained importance in the last decade as a result of the accidents attributed to SEE in aircraft. Due to the development of a higher ceiling, an increase in airflow and a greater autonomy of certain aircrafts, the problem regarding the control of ionizing radiation dose received by the pilots, the crew and sensitive equipment became important in the areas of occupational health, radiation protection and flight safety. This paper presents an overview of the effects of ionizing radiation on devices and embedded systems in aircrafts, identifying and classifying these effects in relation to their potential risks in each device class. The assessment of these effects in avionics is a very important and emerging issue nowadays, which is being discussed by groups of the international scientific community; however, in South America, groups working in this area are still unknown. Consequently, this work is a great contribution and significantly valuable to the area of aeronautical engineering and flight safety associated to the effects of radiation on electronic components embedded in aircraft. (author)

  1. Effects of cosmic radiation on devices and embedded systems in aircrafts

    International Nuclear Information System (INIS)

    Prado, Adriane C.M.; Federico, Claudio A.; Pereira Junior, Evaldo C.F.; Goncalez, Odair L.

    2013-01-01

    Modern avionics systems use new electronic technologies devices that, due to their high degree of sophistication and miniaturization, are more susceptible to the effects of ionizing radiation, particularly the effect called 'Single Event Effect' (SEE) produced by neutron. Studies regarding the effects of radiation on electronic systems for space applications, such as satellites and orbital stations, have already been in progress for several years. However, tolerance requirements and specific studies, focusing on testing dedicated to avionics, have caused concern and gained importance in the last decade as a result of the accidents attributed to SEE in aircraft. Due to the development of a higher ceiling, an increase in airflow and a greater autonomy of certain aircrafts, the problem regarding the control of ionizing radiation dose received by the pilots, the crew and sensitive equipment became important in the areas of occupational health, radiation protection and flight safety. This paper presents an overview of the effects of ionizing radiation on devices and embedded systems in aircrafts, identifying and classifying these effects in relation to their potential risks in each device class. The assessment of these effects in avionics is a very important and emerging issue nowadays, which is being discussed by groups of the international scientific community; however, in South America, groups working in this area are still unknown. Consequently, this work is a great contribution and significantly valuable to the area of aeronautical engineering and flight safety associated to the effects of radiation on electronic components embedded in aircraft. (author)

  2. Response of GaAs charge storage devices to transient ionizing radiation

    Science.gov (United States)

    Hetherington, D. L.; Klem, J. F.; Hughes, R. C.; Weaver, H. T.

    Charge storage devices in which non-equilibrium depletion regions represent stored charge are sensitive to ionizing radiation. This results since the radiation generates electron-hole pairs that neutralize excess ionized dopant charge. Silicon structures, such as dynamic RAM or CCD cells are particularly sensitive to radiation since carrier diffusion lengths in this material are often much longer than the depletion width, allowing collection of significant quantities of charge from quasi-neutral sections of the device. For GaAs the situation is somewhat different in that minority carrier diffusion lengths are shorter than in silicon, and although mobilities are higher, we expect a reduction of radiation sensitivity as suggested by observations of reduced quantum efficiency in GaAs solar cells. Dynamic memory cells in GaAs have potential increased retention times. In this paper, we report the response of a novel GaAs dynamic memory element to transient ionizing radiation. The charge readout technique is nondestructive over a reasonable applied voltage range and is more sensitive to stored charge than a simple capacitor.

  3. Regulatory control of radiation sources and radioactive materials in Ireland

    International Nuclear Information System (INIS)

    McGarry, A.T.; Fenton, D.; O'Flaherty, T.

    2001-01-01

    The primary legislation governing safety in uses of ionizing radiation in Ireland is the Radiological Protection Act, 1991. This Act provided for the establishment in 1992 of the Radiological Protection Institute of Ireland, and gives the Institute the functions and powers which enable it to be the regulatory body for all matters relating to ionizing radiation. A Ministerial Order made under the Act in 2000 consolidates previous regulations and, in particular, provides for the implementation in Irish law of the 1996 European Union Directive which lays down basic safety standards for the protection of the health of workers and the general public against the dangers arising from ionizing radiation. Under the legislation, the custody, use and a number of other activities involving radioactive substances and irradiating apparatus require a licence issued by the Institute. Currently some 1260 licences are in force. Of these, some 850 are in respect of irradiating apparatus only and are issued principally to dentists and veterinary surgeons. The remaining licences involve sealed radiation sources and/or unsealed radioactive substances used in medicine, industry or education. A schedule attached to each licence fully lists the sealed sources to which the licence applies, and also the quantities of radioactive substances which may be acquired or held under the licence. It is an offence to dispose of, or otherwise relinquish possession of, any licensable material other than in accordance with terms and conditions of the licence. Disused sources are returned to the original supplier or, where this is not possible, stored under licence by the licensee who used them. Enforcement of the licensing provisions relies primarily on the programme of inspection of licensees, carried out by the Institute's inspectors. The Institute's Regulatory Service has a complement of four inspectors, one of whom is the Manager of the Service. The Manager reports to one of the Institute's Principal

  4. Sensor device for X-ray beam to evaluate the radiation focal spot

    International Nuclear Information System (INIS)

    Santos, Lara H.E. dos; Schiabel, Homero; Silva, Aderbal A.B. da; Marques, Paulo M.A.; Campos, Marcelo; Slaets, Annie F.F.

    1996-01-01

    A new electronic device to determine the position of the central ray of the radiation beam is proposed. The device aims to provide a perfect alignment of test objects used for evaluating focal spots with this reference axis

  5. Research on the method of establishing the total radiation meter calibration device

    Science.gov (United States)

    Gao, Jianqiang; Xia, Ming; Xia, Junwen; Zhang, Dong

    2015-10-01

    Pyranometer is an instrument used to measure the solar radiation, according to pyranometer differs as installation state, can be respectively measured total solar radiation, reflected radiation, or with the help of shading device for measuring scattering radiation. Pyranometer uses the principle of thermoelectric effect, inductive element adopts winding plating type multi junction thermopile, its surface is coated with black coating with high absorption rate. Hot junction in the induction surface, while the cold junction is located in the body, the cold and hot junction produce thermoelectric potential. In the linear range, the output signal is proportional to the solar irradiance. Traceability to national meteorological station, as the unit of the national legal metrology organizations, the responsibility is to transfer value of the sun and the earth radiation value about the national meteorological industry. Using the method of comparison, with indoor calibration of solar simulator, at the same location, standard pyranometer and measured pyranometer were alternately measured radiation irradiance, depending on the irradiation sensitivity standard pyranometer were calculated the radiation sensitivity of measured pyranometer. This paper is mainly about the design and calibration method of the pyranometer indoor device. The uncertainty of the calibration result is also evaluated.

  6. Radiation damage and rate limitations in tracking devices

    International Nuclear Information System (INIS)

    Gilchriese, M.G.D.

    1984-01-01

    In this note the author briefly discusses radiation damage to wire chambers and silicon strip devices and the electronics that may be associated with each of these. Scintillating fibers and CCD's are not discussed although the former appears to be a potentially radiation-resistant detector. In order to calculate radiation levels and rates the author assumed the following: an inelastic cross section of 100 mb at the SSC - six charged particles per unit of rapidity - photons and neutrons do not contribute to the background (photon conversions are negligible with a thin Be beam pipe) - beam gas interactions and beam losses (except during injection when I assume that the detector is ''off'') are negligible. This is discussed in a later section. - 1 Rad = 3.5 x 10 7 minimum ionizing particlescm 2

  7. 60Co gamma radiation effect on AlGaN//AlN/GaN HEMT devices

    International Nuclear Information System (INIS)

    Wang Yanping; Luo Yinhong; Wang Wei; Zhang Keying; Guo Hongxia; Guo Xiaoqiang; Wang Yuanming

    2013-01-01

    The testing techniques and experimental methods of the 60 Co gamma irradiation effect on AlGaN/AlN/GaN high electron mobility transistors (HEMTs) are established. The degradation of the electrical properties of the device under the actual radiation environment are analyzed theoretically, and studies of the total dose effects of gamma radiation on AlGaN/AlN/GaN HEMTs at three different radiation bias conditions are carried out. The degradation patterns of the main parameters of the AlGaN/AlN/GaN HEMTs at different doses are then investigated, and the device parameters that were sensitive to the gamma radiation induced damage and the total dose level induced device damage are obtained. (authors)

  8. Device for imaging an object by means of masks of spatially modulable electromagnetic radiation or corpuscular radiation of high energy

    International Nuclear Information System (INIS)

    Barrett, H.H.

    1979-01-01

    The radiogram of the thyroid is produced by means of a detector device operating similar to a scintillation camera. Between thyroid and detector device there is placed a mask having modulating areas, permeable and impermeable to radiation succeeding each other with decreasing extension. The scanning signal has got the shape of a radar signal with chirp modulation. The filtering unit used for it is a pulse compression filter. The image of the radiation energy distribution on the recording surface of the detector device is thus decoded and compressed to a number of image points giving the picture of the thyroid. (RW) [de

  9. Reference neutron radiations. Part 2: Calibration fundamentals of radiation protection devices related to the basic quantities characterizing the radiation field

    International Nuclear Information System (INIS)

    2000-01-01

    ISO 8529 consists of the following parts, under the general title Reference neutron radiations: Part 1: Characteristics and methods of production; Part 2: Calibration fundamentals of radiation protection devices related to the basic quantities characterizing the radiation field; Part 3: Calibration of area and personal dosimeters and determination of response as a function of energy and angle of incidence. This Part 2. of ISO 8529 takes as its starting point the neutron sources described in ISO 8529-1. It specifies the procedures to be used for realizing the calibration conditions of radiation protection devices in neutron fields produced by these calibration sources, with particular emphasis on the corrections for extraneous effects (e.g., the neutrons scattered from the walls of the calibration room). In this part of ISO 8529, particular emphasis is placed on calibrations using radionuclide sources (clauses 4 to 6) due to their widespread application, with less details given on the use of accelerator and reactor sources (8.2 and 8.3). This part of ISO 8529 then leads to ISO 8529-3 which gives conversion coefficients and the general rules and procedures for calibration

  10. Commercial power silicon devices as possible routine dosimeters for radiation processing

    International Nuclear Information System (INIS)

    Fuochi, P.G.; Lavalle, M.; Gombia, E.; Mosca, R.; Kovacs, A.V.; Hargittai, P.; Vitanza, A.; Patti, A.

    2001-01-01

    The use of silicon devices as possible radiation dosimeters has been investigated in this study. A bipolar power transistor in TO126 plastic packaging has been selected. Irradiations, with doses in the range from 50 Gy up to 5 kGy, have been performed at room temperature using different radiation sources ( 60 Co g source, 2.5, 4 and 12 MeV electron accelerators). Few irradiations with g rays were also done at different temperatures. A physical parameter, T, related to the charge carrier lifetime, has been found to change as a function of irradiation dose. This change is radiation energy dependent. Long term stability of the electron irradiated transistors has been checked by means of a reliability test ('high temperature reverse bias', HTRB) at 150 deg. C for 1000 h. Deep level transient spectroscopy (DLTS) measurements have been performed on the irradiated devices to identify the recombination centres introduced by the radiation treatment. The results obtained confirm that these transistors could be used as routine radiation dosimeters in a certain dose range. More work needs to be done particularly with g rays in the low dose region (50-200 Gy) and with low energy electrons. (author)

  11. Radiation dermatitis caused by a bolus effect from an abdominal compression device

    International Nuclear Information System (INIS)

    Connor, Michael; Wei, Randy L.; Yu, Suhong; Sehgal, Varun; Klempner, Samuel J.; Daroui, Parima

    2016-01-01

    American Association of Physicists in Medicine (AAPM) Task Group 176 evaluated the dosimetric effects caused by couch tops and immobilization devices. The report analyzed the extensive physics-based literature on couch tops, stereotactic body radiation therapy (SBRT) frames, and body immobilization bags, while noting the scarcity of clinical reports of skin toxicity because of external devices. Here, we present a clinical case report of grade 1 abdominal skin toxicity owing to an abdominal compression device. We discuss the dosimetric implications of the utilized treatment plan as well as post hoc alternative plans and quantify differences in attenuation and skin dose/build-up between the device, a lower-density alternative device, and an open field. The description of the case includes a 66-year-old male with HER2 amplified poorly differentiated distal esophageal adenocarcinoma treated with neoadjuvant chemo-radiation and the use of an abdominal compression device. Radiation was delivered using volumetric modulated arc therapy (VMAT) with 2 arcs using abdominal compression and image guidance. The total dose was 50.4 Gy delivered over 40 elapsed days. With 2 fractions remaining, the patient developed dermatitis in the area of the compression device. The original treatment plan did not include a contour of the device. Alternative post hoc treatment plans were generated, one to contour the device and a second with anterior avoidance. In conclusion, replanning with the device contoured revealed the bolus effect. The skin dose increased from 27 to 36 Gy. planned target volume (PTV) coverage at 45 Gy was reduced to 76.5% from 95.8%. The second VMAT treatment plan with an anterior avoidance sector and more oblique beam angles maintained PTV coverage and spared the anterior wall, however at the expense of substantially increased dose to lung. This case report provides an important reminder of the bolus effect from external devices such as abdominal compression. Special

  12. Radiation dermatitis caused by a bolus effect from an abdominal compression device

    Energy Technology Data Exchange (ETDEWEB)

    Connor, Michael; Wei, Randy L.; Yu, Suhong; Sehgal, Varun [Department of Radiation Oncology, University of California, Irvine Medical Center, Orange, CA (United States); Klempner, Samuel J. [Department of Medicine, Division of Hematology/Oncology, University of California, Orange, CA (United States); Daroui, Parima, E-mail: pdaroui@uci.edu [Department of Radiation Oncology, University of California, Irvine Medical Center, Orange, CA (United States)

    2016-10-01

    American Association of Physicists in Medicine (AAPM) Task Group 176 evaluated the dosimetric effects caused by couch tops and immobilization devices. The report analyzed the extensive physics-based literature on couch tops, stereotactic body radiation therapy (SBRT) frames, and body immobilization bags, while noting the scarcity of clinical reports of skin toxicity because of external devices. Here, we present a clinical case report of grade 1 abdominal skin toxicity owing to an abdominal compression device. We discuss the dosimetric implications of the utilized treatment plan as well as post hoc alternative plans and quantify differences in attenuation and skin dose/build-up between the device, a lower-density alternative device, and an open field. The description of the case includes a 66-year-old male with HER2 amplified poorly differentiated distal esophageal adenocarcinoma treated with neoadjuvant chemo-radiation and the use of an abdominal compression device. Radiation was delivered using volumetric modulated arc therapy (VMAT) with 2 arcs using abdominal compression and image guidance. The total dose was 50.4 Gy delivered over 40 elapsed days. With 2 fractions remaining, the patient developed dermatitis in the area of the compression device. The original treatment plan did not include a contour of the device. Alternative post hoc treatment plans were generated, one to contour the device and a second with anterior avoidance. In conclusion, replanning with the device contoured revealed the bolus effect. The skin dose increased from 27 to 36 Gy. planned target volume (PTV) coverage at 45 Gy was reduced to 76.5% from 95.8%. The second VMAT treatment plan with an anterior avoidance sector and more oblique beam angles maintained PTV coverage and spared the anterior wall, however at the expense of substantially increased dose to lung. This case report provides an important reminder of the bolus effect from external devices such as abdominal compression. Special

  13. Transient photoconductive gain in a-Si:H devices and its applications in radiation detection

    International Nuclear Information System (INIS)

    Lee, H.K.; Suh, T.S.; Choe, B.Y.; Shinn, K.S.; Perez-Mendez, V.

    1997-01-01

    Using the transient behavior of the photoconductive-gain mechanism, a signal gain in radiation detection with a-Si:H devices may be possible. The photoconductive gain mechanism in two types of hydrogenated amorphous silicon devices, p-i-n and n-i-n configurations, was investigated in connection with applications to radiation detection. Photoconductive gain was measured in two time scales: one for short pulses of visible light ( 2 . Various gain results are discussed in terms of the device structure, applied bias and dark-current density. (orig.)

  14. Radiation safety in aviation

    International Nuclear Information System (INIS)

    2005-06-01

    The guide presents the requirements governing radiation safety of aircrews exposed to cosmic radiation and monitoring of such exposure. It applies to enterprises engaged in aviation under a Finnish operating licence and to Finnish military aviation at altitudes exceeding 8,000 metres. The radiation exposure of aircrews at altitudes of less than 8,000 metres is so minimal that no special measures are generally required to investigate or limit exposure to radiation

  15. Radiation Practices. Annual Report 2005

    International Nuclear Information System (INIS)

    Rantanen, E.

    2006-06-01

    1764 safety licences for the use of radiation were current at the end of 2005. 1907 responsible parties were engaged in notifiable licence-exempt dental X-ray practices. Regulatory control of the use of radiation was performed through regular inspections performed at places of use, test packages sent by post to dental X-ray facilities and maintenance of the Dose Register. Radiation safety guides were also published and research was conducted in support of regulatory control. STUK conducted 458 inspections of licensed practices and 62 inspections of notifiable licence-exempt dental X-ray practices in 2005. 273 remedial orders and recommendations were issued. Use of one appliance was prohibited. A total of 11 698 workers engaged in radiation work were subject to individual monitoring in 2005. 137 000 dose entries were made in the Dose Register. In no case did the individual dose of any worker exceed the dose limits stipulated in the Radiation Decree. Regulatory control of natural radiation focused on radon at workplaces and exposure of aircrews to cosmic radiation. 90 workplaces including a total of 233 work areas were subject to radon monitoring during 2005. 2600 pilots and cabin crew members were monitored for exposure to cosmic radiation. Metrological activities continued with calibration and development work as in previous years. Regulatory control of the use of non-ionizing radiation in 2005 continued to focus particularly on mobile phones and sunbeds. 15 mobile phone types were tested in market surveillance of mobile phones. A total of 44 sunbed appliances were inspected at 36 sunbed facilities. Most research and development work took place within jointly financed research projects. This work focused especially on developing testing and measuring methods for determining exposure to electromagnetic fields caused by mobile phones and their base stations. There were 13 abnormal incidents involving the use of radiation in 2005. Eight of these incidents concerned

  16. The research of nuclear experiment radiation environment wireless alarm device

    International Nuclear Information System (INIS)

    Wang Xiaoqiong; Wang Pan; Fang Fang

    2009-01-01

    This article introduces based on monolithic integrated circuit's nuclear experiment radiation environment wireless alarm device's software and hardware design. The system by G-M tube, high-pressured module, signal conditioning circuit, power source module, monolithic integrated circuit and wireless transmission module is composed. The device has low power consumption, high performance, high accuracy detection, easy maintenance, small size, simple operation, and other features, and has a broad application prospects. (authors)

  17. Radiation-resistant requirements analysis of device and control component for advanced spent fuel management process

    Energy Technology Data Exchange (ETDEWEB)

    Song, Tai Gil; Park, G. Y.; Kim, S. Y.; Lee, J. Y.; Kim, S. H.; Yoon, J. S. [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2002-02-01

    It is known that high levels of radiation can cause significant damage by altering the properties of materials. A practical understanding of the effects of radiation - how radiation affects various types of materials and components - is required to design equipment to operate reliably in a gamma radiation environment. When designing equipment to operate in a high gamma radiation environment, such as will be present in a nuclear spent fuel handling facility, several important steps should be followed. In order to active test of the advanced spent fuel management process, the radiation-resistant analysis of the device and control component for active test which is concerned about the radiation environment is conducted. Also the system design process is analysis and reviewed. In the foreign literature, 'threshold' values are generally reported. the threshold values are normally the dose required to begin degradation in a particular material property. The radiation effect analysis for the device of vol-oxidation and metalization, which are main device for the advanced spent fuel management process, is performed by the SCALE 4.4 code. 5 refs., 4 figs., 13 tabs. (Author)

  18. Signal Processing Device (SPD) for networked radiation monitoring system

    International Nuclear Information System (INIS)

    Dharmapurikar, A.; Bhattacharya, S.; Mukhopadhyay, P.K.; Sawhney, A.; Patil, R.K.

    2010-01-01

    A networked radiation and parameter monitoring system with three tier architecture is being developed. Signal Processing Device (SPD) is a second level sub-system node in the network. SPD is an embedded system which has multiple input channels and output communication interfaces. It acquires and processes data from first level parametric sensor devices, and sends to third level devices in response to request commands received from host. It also performs scheduled diagnostic operations and passes on the information to host. It supports inputs in the form of differential digital signals and analog voltage signals. SPD communicates with higher level devices over RS232/RS422/USB channels. The system has been designed with main requirements of minimal power consumption and harsh environment in radioactive plants. This paper discusses the hardware and software design details of SPD. (author)

  19. Exploring graphene field effect transistor devices to improve spectral resolution of semiconductor radiation detectors

    Energy Technology Data Exchange (ETDEWEB)

    Harrison, Richard Karl [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Howell, Stephen Wayne [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Martin, Jeffrey B. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hamilton, Allister B. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2013-12-01

    Graphene, a planar, atomically thin form of carbon, has unique electrical and material properties that could enable new high performance semiconductor devices. Graphene could be of specific interest in the development of room-temperature, high-resolution semiconductor radiation spectrometers. Incorporating graphene into a field-effect transistor architecture could provide an extremely high sensitivity readout mechanism for sensing charge carriers in a semiconductor detector, thus enabling the fabrication of a sensitive radiation sensor. In addition, the field effect transistor architecture allows us to sense only a single charge carrier type, such as electrons. This is an advantage for room-temperature semiconductor radiation detectors, which often suffer from significant hole trapping. Here we report on initial efforts towards device fabrication and proof-of-concept testing. This work investigates the use of graphene transferred onto silicon and silicon carbide, and the response of these fabricated graphene field effect transistor devices to stimuli such as light and alpha radiation.

  20. Dosimetric studies for gamma radiation validation of medical devices

    International Nuclear Information System (INIS)

    Soliman, Y.S.; Beshir, W.B.; Abdel-Fattah, A.A.; Abdel-Rehim, F.

    2013-01-01

    The delivery and validation of a specified dose to medical devices are key concerns to operators of gamma radiation facilities. The objective of the present study was to characterize the industrial gamma radiation facility and map the dose distribution inside the product-loading pattern during the validation and routine control of the sterilization process using radiochromic films. Cardboard phantoms were designed to achieve the homogeneity of absorbed doses. The uncertainty of the dose delivered during validation of the sterilization process was assessed. - Highlights: ► Using γ-rays for sterilization of hollow fiber dialyzers and blood tubing sets according to ISO 11137, 2006. ► Dosimetry studies of validations of γ-irradiation facility and sterilized medical devices. ► Places of D min and D max have been determined using FWT-60 films. ► Determining the target minimum doses required to meet the desired SAL of 10 −6 for the two products.

  1. Irradiation technology Pt. 2. Research devices. Glossary on radiation technology. Besugarzastechnika 2. resz. Kiserleti berendezesek, sugartechnikai kislexikon

    Energy Technology Data Exchange (ETDEWEB)

    Foeldiak, G; Stenger, V

    1982-01-01

    It is a textbook and manual of a training course held at the Budapest Technical University for operators of irradiation devices. Calculation methods of radiation technology (estimation of activity variation, space dependence of dose rates, shielding, efficiency) are presented. Instructions for laboratory exercises (dose and dose rate measurements, sterilization by irradiation, handling of irradiation devices) involved in the course given. Two laboratory irradiation devices (RH-GAMMA-30, produced in the Soviet Union and the K-120-type semi-large scale device of the Isotope Institute of the Hungarian Academy of Sciences are described in detail. Handling instructions for the two devices and radiation protection regulations are given. A brief glossary in the field of radiation technology is added.

  2. Medical Device Recalls in Radiation Oncology: Analysis of US Food and Drug Administration Data, 2002-2015

    International Nuclear Information System (INIS)

    Connor, Michael J.; Tringale, Kathryn; Moiseenko, Vitali; Marshall, Deborah C.; Moore, Kevin; Cervino, Laura; Atwood, Todd; Brown, Derek; Mundt, Arno J.; Pawlicki, Todd; Recht, Abram; Hattangadi-Gluth, Jona A.

    2017-01-01

    Purpose: To analyze all recalls involving radiation oncology devices (RODs) from the US Food and Drug Administration (FDA)'s recall database, comparing these with non–radiation oncology device recalls to identify discipline-specific trends that may inform improvements in device safety. Methods and Materials: Recall data on RODs from 2002 to 2015 were sorted into 4 product categories (external beam, brachytherapy, planning systems, and simulation systems). Outcomes included determined cause of recall, recall class (severity), quantity in commerce, time until recall termination (date FDA determines recall is complete), and time since 510(k) approval. Descriptive statistics were performed with linear regression of time-series data. Results for RODs were compared with those for other devices by Pearson χ"2 test for categorical data and 2-sample Kolmogorov-Smirnov test for distributions. Results: There were 502 ROD recalls and 9534 other class II device recalls during 2002 to 2015. Most recalls were for external beam devices (66.7%) and planning systems (22.9%), and recall events peaked in 2011. Radiation oncology devices differed significantly from other devices in all recall outcomes (P≤.04). Recall cause was commonly software related (49% vs 10% for other devices). Recall severity was more often moderate among RODs (97.6% vs 87.2%) instead of severe (0.2% vs 4.4%; P<.001). Time from 510(k) market approval to recall was shorter among RODs (P<.001) and progressively shortened over time. Radiation oncology devices had fewer recalled devices in commerce than other devices (P<.001). Conclusions: Compared with other class II devices, RODs experience recalls sooner after market approval and are trending sooner still. Most of these recalls were moderate in severity, and software issues are prevalent. Comprehensive analysis of recall data can identify areas for device improvement, such as better system design among RODs.

  3. Medical Device Recalls in Radiation Oncology: Analysis of US Food and Drug Administration Data, 2002-2015

    Energy Technology Data Exchange (ETDEWEB)

    Connor, Michael J. [Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, California (United States); University of California Irvine School of Medicine, Irvine, California (United States); Tringale, Kathryn; Moiseenko, Vitali; Marshall, Deborah C.; Moore, Kevin; Cervino, Laura; Atwood, Todd; Brown, Derek; Mundt, Arno J.; Pawlicki, Todd [Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, California (United States); Recht, Abram [Department of Radiation Oncology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts (United States); Hattangadi-Gluth, Jona A., E-mail: jhattangadi@ucsd.edu [Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, California (United States)

    2017-06-01

    Purpose: To analyze all recalls involving radiation oncology devices (RODs) from the US Food and Drug Administration (FDA)'s recall database, comparing these with non–radiation oncology device recalls to identify discipline-specific trends that may inform improvements in device safety. Methods and Materials: Recall data on RODs from 2002 to 2015 were sorted into 4 product categories (external beam, brachytherapy, planning systems, and simulation systems). Outcomes included determined cause of recall, recall class (severity), quantity in commerce, time until recall termination (date FDA determines recall is complete), and time since 510(k) approval. Descriptive statistics were performed with linear regression of time-series data. Results for RODs were compared with those for other devices by Pearson χ{sup 2} test for categorical data and 2-sample Kolmogorov-Smirnov test for distributions. Results: There were 502 ROD recalls and 9534 other class II device recalls during 2002 to 2015. Most recalls were for external beam devices (66.7%) and planning systems (22.9%), and recall events peaked in 2011. Radiation oncology devices differed significantly from other devices in all recall outcomes (P≤.04). Recall cause was commonly software related (49% vs 10% for other devices). Recall severity was more often moderate among RODs (97.6% vs 87.2%) instead of severe (0.2% vs 4.4%; P<.001). Time from 510(k) market approval to recall was shorter among RODs (P<.001) and progressively shortened over time. Radiation oncology devices had fewer recalled devices in commerce than other devices (P<.001). Conclusions: Compared with other class II devices, RODs experience recalls sooner after market approval and are trending sooner still. Most of these recalls were moderate in severity, and software issues are prevalent. Comprehensive analysis of recall data can identify areas for device improvement, such as better system design among RODs.

  4. Extreme Radiation Hardness and Space Qualification of AlGaN Optoelectronic Devices

    International Nuclear Information System (INIS)

    Sun, Ke-Xun; MacNeil, Lawrence; Balakrishnan, Kathik; Hultgren, Eric; Goebel, John; Bilenko, Yuri; Yang, Jinwei; Sun, Wenhong; Shatalov, Max; Hu, Xuhong; Gaska, Remis

    2010-01-01

    Unprecedented radiation hardness and environment robustness are required in the new generation of high energy density physics (HEDP) experiments and deep space exploration. National Ignition Facility (NIF) break-even shots will have a neutron yield of 10 15 or higher. The Europa Jupiter System Mission (EJSM) mission instruments will be irradiated with a total fluence of 10 12 protons/cm 2 during the space journey. In addition, large temperature variations and mechanical shocks are expected in these applications under extreme conditions. Hefty radiation and thermal shields are required for Si and GaAs based electronics and optoelectronics devices. However, for direct illumination and imaging applications, shielding is not a viable option. It is an urgent task to search for new semiconductor technologies and to develop radiation hard and environmentally robust optoelectronic devices. We will report on our latest systematic experimental studies on radiation hardness and space qualifications of AlGaN optoelectronic devices: Deep UV Light Emitting Diodes (DUV LEDs) and solarblind UV Photodiodes (PDs). For custom designed AlGaN DUV LEDs with a central emission wavelength of 255 nm, we have demonstrated its extreme radiation hardness up to 2 x 10 12 protons/cm 2 with 63.9 MeV proton beams. We have demonstrated an operation lifetime of over 26,000 hours in a nitrogen rich environment, and 23,000 hours of operation in vacuum without significant power drop and spectral shift. The DUV LEDs with multiple packaging styles have passed stringent space qualifications with 14 g random vibrations, and 21 cycles of 100K temperature cycles. The driving voltage, current, emission spectra and optical power (V-I-P) operation characteristics exhibited no significant changes after the space environmental tests. The DUV LEDs will be used for photoelectric charge management in space flights. For custom designed AlGaN UV photodiodes with a central response wavelength of 255 nm, we have

  5. Modeling of transient ionizing radiation effects in bipolar devices at high dose-rates

    International Nuclear Information System (INIS)

    FJELDLY, T.A.; DENG, Y.; SHUR, M.S.; HJALMARSON, HAROLD P.; MUYSHONDT, ARNOLDO

    2000-01-01

    To optimally design circuits for operation at high intensities of ionizing radiation, and to accurately predict their a behavior under radiation, precise device models are needed that include both stationary and dynamic effects of such radiation. Depending on the type and intensity of the ionizing radiation, different degradation mechanisms, such as photoelectric effect, total dose effect, or single even upset might be dominant. In this paper, the authors consider the photoelectric effect associated with the generation of electron-hole pairs in the semiconductor. The effects of low radiation intensity on p-II diodes and bipolar junction transistors (BJTs) were described by low-injection theory in the classical paper by Wirth and Rogers. However, in BJTs compatible with modem integrated circuit technology, high-resistivity regions are often used to enhance device performance, either as a substrate or as an epitaxial layer such as the low-doped n-type collector region of the device. Using low-injection theory, the transient response of epitaxial BJTs was discussed by Florian et al., who mainly concentrated on the effects of the Hi-Lo (high doping - low doping) epilayer/substrate junction of the collector, and on geometrical effects of realistic devices. For devices with highly resistive regions, the assumption of low-level injection is often inappropriate, even at moderate radiation intensities, and a more complete theory for high-injection levels was needed. In the dynamic photocurrent model by Enlow and Alexander. p-n junctions exposed to high-intensity radiation were considered. In their work, the variation of the minority carrier lifetime with excess carrier density, and the effects of the ohmic electric field in the quasi-neutral (q-n) regions were included in a simplified manner. Later, Wunsch and Axness presented a more comprehensive model for the transient radiation response of p-n and p-i-n diode geometries. A stationary model for high-level injection in p

  6. Characterization of Radiation Hardened Bipolar Linear Devices for High Total Dose Missions

    Science.gov (United States)

    McClure, Steven S.; Harris, Richard D.; Rax, Bernard G.; Thorbourn, Dennis O.

    2012-01-01

    Radiation hardened linear devices are characterized for performance in combined total dose and displacement damage environments for a mission scenario with a high radiation level. Performance at low and high dose rate for both biased and unbiased conditions is compared and the impact to hardness assurance methodology is discussed.

  7. Dylan Thomas’s The Map of Love: The Poetic Licence

    Directory of Open Access Journals (Sweden)

    S. Bharadwaj

    2015-09-01

    Full Text Available In the early poetry, 18 Poems and 25 Poems, Dylan Thomas speaks of his awareness of the artistic heritage and also of his poetic freedom resulting in a poetic force.The Map of Love vindicates, while mapping out the continuous process of exploiting poetic licence in his works, that the poetry of the past cannot fully serve the demands of the present. Apparently, the third book offers a comparative estimate of  the time-conscientious poets, Cecil Day Lewis, Stephen Spender, and Louis MacNeice and the life-conscious War poets, Roy Fuller, Alan  Rook, and Keidrych Rhys.The issues involved are wider and cover the whole range of aesthetic transcendence and historic sense of Auden. Thomas, “refusing to fall in love with God … gave himself to the love of created things … accepting only what he could see” and created his own poetic design, “an ideal surely which … here if anywhere is feasible.” This explains why Thomas’s earth-concentric poetic licence is deeper than Auden’s ideology-centric poetic justice. The War poets heaved a sigh of relief as the world-concentric Thomas’s 18 Poems offers a hope for poetry, “life-blood” for their poetic mind fumbling around Auden’s structural consciousness. The poetic licence developed in The Map of Love is, therefore, central to an understanding of Thomas’s entire poetic ouvre, more particularly, of the maturer poetry of the later phase carving out a road taken already to immortality. In the literary study of this collection, Walford Davies and John Ackerman refer to Thomas’s “querying the nature” of  his own “earlier adolescent attitudes.” However, as their study remains limited to general or literal statements, denotative or elucidative meaning of a few individual poems, they fail to render the core of the poem, the totality of its meaning. The poetic language of this transitional  poem is endowed with implications, suggestions, and modifications. Hence, this paper

  8. Asymmetric devices based on carbon nanotubes for terahertz-range radiation detection

    Energy Technology Data Exchange (ETDEWEB)

    Fedorov, G. E., E-mail: gefedorov@mail.ru; Stepanova, T. S.; Gazaliev, A. Sh.; Gaiduchenko, I. A.; Kaurova, N. S.; Voronov, B. M.; Goltzman, G. N. [Moscow State Pedagogical University (Russian Federation)

    2016-12-15

    Various asymmetric detecting devices based on carbon nanotubes (CNTs) are studied. The asymmetry is understood as inhomogeneous properties along the conducting channel. In the first type of devices, an inhomogeneous morphology of the CNT grid is used. In the second type of devices, metals with highly varying work functions are used as the contact material. The relation between the sensitivity and detector configuration is analyzed. Based on the data obtained, approaches to the development of an efficient detector of terahertz radiation, based on carbon nanotubes are proposed.

  9. Radiation Testing, Characterization and Qualification Challenges for Modern Microelectronics and Photonics Devices and Technologies

    Science.gov (United States)

    LaBel, Kenneth A.; Cohn, Lewis M.

    2008-01-01

    At GOMAC 2007, we discussed a selection of the challenges for radiation testing of modern semiconductor devices focusing on state-of-the-art memory technologies. This included FLASH non-volatile memories (NVMs) and synchronous dynamic random access memories (SDRAMs). In this presentation, we extend this discussion in device packaging and complexity as well as single event upset (SEU) mechanisms using several technology areas as examples including: system-on-a-chip (SOC) devices and photonic or fiber optic systems. The underlying goal is intended to provoke thought for understanding the limitations and interpretation of radiation testing results.

  10. The solar ultraviolet B radiation protection provided by shading devices with regard to its diffuse component.

    Science.gov (United States)

    Kudish, Avraham I; Harari, Marco; Evseev, Efim G

    2011-10-01

    The composition of the incident solar global ultraviolet B (UVB) radiation with regard to its beam and diffuse radiation fractions is highly relevant with regard to outdoor sun protection. This is especially true with respect to sun protection during leisure-time outdoor sun exposure at the shore and pools, where people tend to escape the sun under shade trees or different types of shading devices, e.g., umbrellas, overhangs, etc., believing they offer protection from the erythemal solar radiation. The degree of sun protection offered by such devices is directly related to the composition of the solar global UVB radiation, i.e., its beam and diffuse fractions. The composition of the incident solar global UVB radiation can be determined by measuring the global UVB (using Solar Light Co. Inc., Model 501A UV-Biometer) and either of its components. The beam component of the UVB radiation was determined by measuring the normal incidence beam radiation using a prototype, tracking instrument consisting of a Solar Light Co. Inc. Model 501A UV-Biometer mounted on an Eppley Solar Tracker Model St-1. The horizontal beam component of the global UVB radiation was calculated from the measured normal incidence using a simple geometric correlation and the diffuse component is determined as the difference between global and horizontal beam radiations. Horizontal and vertical surfaces positioned under a horizontal overhang/sunshade or an umbrella are not fully protected from exposure to solar global UVB radiation. They can receive a significant fraction of the UVB radiation, depending on their location beneath the shading device, the umbrella radius and the albedo (reflectance) of the surrounding ground surface in the case of a vertical surface. Shading devices such as an umbrella or horizontal overhang/shade provide relief from the solar global radiation and do block the solar global UVB radiation to some extent; nevertheless, a significant fraction of the solar global UVB

  11. A survey of synchrotron radiation devices producing circular or variable polarization

    International Nuclear Information System (INIS)

    Kim, K.J.

    1990-01-01

    This paper reviews the properties and operating principles of the new types of synchrotron radiation devices that produce circular polarization, or polarization that can be modulated in arbitrary fashion

  12. Short and long term ionizing radiation effects on charge-coupled devices in radiation environment of high-intensity heavy ion accelerators

    International Nuclear Information System (INIS)

    Belousov, A; Mustafin, E; Ensinger, W

    2012-01-01

    Radiation effects on semiconductor devices is a topical issue for high-intensity accelerator projects. In particular it concerns Charge-Coupled Device (CCD) cameras, which are widely used for beam profile monitoring and surveillance in high radiation environment. One should have a clear idea of short and long term radiation effects on such devices. To study these effects, a CCD camera was placed in positions less than half meter away from beam loss point. Primary heavy ion beam of 0.95GeV/n Uranium was dumped into a thick aluminium target creating high fluences of secondary particles (e.g., gammas, neutrons, protons). Effects of these particles on CCD camera were scored with LabView based acquisition software. Monte Carlo calculations with FLUKA code were performed to obtain fluence distributions for different particles and make relevant comparisons. Long term total ionising dose effects are represented by dark current increase, which was scored throughout experiment. Instant radiation effects are represented by creation of charge in CCD cells by ionising particles. Relation of this charge to beam intensity was obtained for different camera positions and fluences within 5 orders of magnitude ranges. With high intensities this charge is so high that it may dramatically influence data obtained from CCD camera used in high radiation environment. The linearity of described above relation confirms linear response of CCD to ionizing radiation. It gives an opportunity to find a new application to CCD cameras as beam loss monitors (BLM).

  13. Medical surveillance according to the resolution radiation protection nuclear-power-law in working with ionizing radiation

    International Nuclear Information System (INIS)

    1988-01-01

    The rules with regard to the medical surveillance of persons who, during the execution of their duties, may be exposed to certain amounts of ionizing radiation are treated. After an explanation of the general starting points of the policy with regard to radiation hygiene, two governing tools are reviewed: the set of licences and the radiation hygiene standards. 10 refs.; 1 table

  14. Short term ionizing radiation impact on charge-coupled devices in radiation environment of high-intensity heavy ion accelerators

    International Nuclear Information System (INIS)

    Belousov, A.; Mustafin, E.; Ensinger, W.

    2012-01-01

    This paper presents a first approach on studies of the results of short term ionizing radiation impact on charge-coupled device (CCD) chips in conditions typical for high-intensity ion accelerator areas. Radiation effects on semiconductor devices are a topical issue for high-intensity accelerator projects. In particular it concerns CCD cameras that are widely used for beam profile monitoring and surveillance in high radiation environment. 65 CCD cameras are going to be installed in the FAIR machines. It is necessary to have good understanding of radiation effects and their contribution to measured signal in CCD chips. A phenomenon of single event upset (SEU) in CCD chips is studied in the following experiment. By SEU in CCD chip we mean an event when an ionizing particle hits the CCD matrix cell and produces electron-hole pairs that are then collected and converted to a signal that is higher than certain level defined by author. Practically, it means that a certain cell will appear as a bright pixel on the resulting image from a chip. (authors)

  15. Qualifications of persons working in radiation user's organization and radiation protection training required for competence

    International Nuclear Information System (INIS)

    2004-04-01

    The Guide sets out the requirements governing the qualifications of persons working in userAes organizations and the radiation protection training required for such competence. It also sets out the requirements for training organizations arranging radiation safety officer training and exams. The Guide applies only to uses of radiation requiring a afety licence. The requirements for userAes organizations are set out in Guide ST 1.4

  16. New small devices for radiation detection: the Wee Pocket Chirper and the Portable Multichannel Analyzer

    International Nuclear Information System (INIS)

    Umbarger, C.J.

    1980-08-01

    Recent events have demonstrated the need for improved capability to monitor the exposure of workers to radiation and, in general, to identify and measure the many forms of radioactive materials found throughout the nuclear industry. Two radiation monitoring devices have been developed that are much smaller than existing instruments, yet exhibit superior performance and a longer battery life. The first instrument, the Wee Pocket Chirper, is a tiny, battery-powered warning device that chirps when exposed to radiation. The second instrument is a portable battery-powered, computer-based, multichannel analyzer that allows the user to examine radiation fields and to identify the types and amounts of radioactive materials present

  17. Energy harvesting devices for harvesting energy from terahertz electromagnetic radiation

    Science.gov (United States)

    Novack, Steven D.; Kotter, Dale K.; Pinhero, Patrick J.

    2012-10-09

    Methods, devices and systems for harvesting energy from electromagnetic radiation are provided including harvesting energy from electromagnetic radiation. In one embodiment, a device includes a substrate and one or more resonance elements disposed in or on the substrate. The resonance elements are configured to have a resonant frequency, for example, in at least one of the infrared, near-infrared and visible light spectra. A layer of conductive material may be disposed over a portion of the substrate to form a ground plane. An optical resonance gap or stand-off layer may be formed between the resonance elements and the ground plane. The optical resonance gap extends a distance between the resonance elements and the layer of conductive material approximately one-quarter wavelength of a wavelength of the at least one resonance element's resonant frequency. At least one energy transfer element may be associated with the at least one resonance element.

  18. Results of environmental radiation monitoring and meteorology measurements (material prepared for obtaining the licence for RA reactor experimental operation); Rezultati merenja zracenja u okolini i rezultati meteoroloskih merenja (materijal pripremljen radi dobijanja dozvole za pustanje Reaktora RA u probni rad)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1980-10-15

    According to the demands for obtaining the licence for restarting the Ra reactor and the experimental operation this document includes the radiation monitoring measured data in the working space and environment of the RA reactor, i.e. Boris Kidric Institute. The meteorology measured data are included as well. All the measurements are performed according to the radiation protection program applied actually from the first reactor start-up at the end of 1959. [Serbo-Croat] Saglasno zahtevu za dobijanje dozvole za ponovno pustanje u probni rad reaktora RA, ovaj dokument sadrzi rezultate merenja zracenja u okolini (radnoj i zivotnoj) reaktora RA odnosno instituta 'Boris Kidric' kao i podatke o meteoroloskim merenjima. Sve merenja rade se prema programu mera zastite od zracenja koje se sprovode prakticno od prvog pustanja reaktora u rad krajem 1959. godine.

  19. Space Radiation Environment Prediction for VLSI microelectronics devices onboard a LEO Satellite using OMERE-Trad Software

    Science.gov (United States)

    Sajid, Muhammad

    This tutorial/survey paper presents the assessment/determination of level of hazard/threat to emerging microelectronics devices in Low Earth Orbit (LEO) space radiation environment with perigee at 300 Km, apogee at 600Km altitude having different orbital inclinations to predict the reliability of onboard Bulk Built-In Current Sensor (BBICS) fabricated in 350nm technology node at OptMA Lab. UFMG Brazil. In this context, the various parameters for space radiation environment have been analyzed to characterize the ionizing radiation environment effects on proposed BBICS. The Space radiation environment has been modeled in the form of particles trapped in Van-Allen radiation belts(RBs), Energetic Solar Particles Events (ESPE) and Galactic Cosmic Rays (GCR) where as its potential effects on Device- Under-Test (DUT) has been predicted in terms of Total Ionizing Dose (TID), Single-Event Effects (SEE) and Displacement Damage Dose (DDD). Finally, the required mitigation techniques including necessary shielding requirements to avoid undesirable effects of radiation environment at device level has been estimated /determined with assumed standard thickness of Aluminum shielding. In order to evaluate space radiation environment and analyze energetic particles effects on BBICS, OMERE toolkit developed by TRAD was utilized.

  20. Organic materials and devices for detecting ionizing radiation

    Science.gov (United States)

    Doty, F Patrick [Livermore, CA; Chinn, Douglas A [Livermore, CA

    2007-03-06

    A .pi.-conjugated organic material for detecting ionizing radiation, and particularly for detecting low energy fission neutrons. The .pi.-conjugated materials comprise a class of organic materials whose members are intrinsic semiconducting materials. Included in this class are .pi.-conjugated polymers, polyaromatic hydrocarbon molecules, and quinolates. Because of their high resistivities (.gtoreq.10.sup.9 ohmcm), these .pi.-conjugated organic materials exhibit very low leakage currents. A device for detecting and measuring ionizing radiation can be made by applying an electric field to a layer of the .pi.-conjugated polymer material to measure electron/hole pair formation. A layer of the .pi.-conjugated polymer material can be made by conventional polymer fabrication methods and can be cast into sheets capable of covering large areas. These sheets of polymer radiation detector material can be deposited between flexible electrodes and rolled up to form a radiation detector occupying a small volume but having a large surface area. The semiconducting polymer material can be easily fabricated in layers about 10 .mu.m to 100 .mu.m thick. These thin polymer layers and their associated electrodes can be stacked to form unique multi-layer detector arrangements that occupy small volume.

  1. Parasitic effects in superconducting quantum interference device-based radiation comb generators

    Energy Technology Data Exchange (ETDEWEB)

    Bosisio, R., E-mail: riccardo.bosisio@nano.cnr.it [SPIN-CNR, Via Dodecaneso 33, 16146 Genova (Italy); NEST, Instituto Nanoscienze-CNR and Scuola Normale Superiore, I-56127 Pisa (Italy); Giazotto, F., E-mail: giazotto@sns.it [NEST, Instituto Nanoscienze-CNR and Scuola Normale Superiore, I-56127 Pisa (Italy); Solinas, P., E-mail: paolo.solinas@spin.cnr.it [SPIN-CNR, Via Dodecaneso 33, 16146 Genova (Italy)

    2015-12-07

    We study several parasitic effects on the implementation of a Josephson radiation comb generator based on a dc superconducting quantum interference device (SQUID) driven by an external magnetic field. This system can be used as a radiation generator similarly to what is done in optics and metrology, and allows one to generate up to several hundreds of harmonics of the driving frequency. First we take into account how the assumption of a finite loop geometrical inductance and junction capacitance in each SQUID may alter the operation of the devices. Then, we estimate the effect of imperfections in the fabrication of an array of SQUIDs, which is an unavoidable source of errors in practical situations. We show that the role of the junction capacitance is, in general, negligible, whereas the geometrical inductance has a beneficial effect on the performance of the device. The errors on the areas and junction resistance asymmetries may deteriorate the performance, but their effect can be limited to a large extent by a suitable choice of fabrication parameters.

  2. Ministerial Order of 13 April 1984 on applications for licences for the import, manufacture, preparation, putting up for sale or sale of unsealed radioisotopes used in human or veterinary medicine

    International Nuclear Information System (INIS)

    1984-01-01

    This Order specifies the conditions for applications for licences for the import, manufacture, preparation, putting up for sale or sale of unsealed radioisotopes used in human or veterinary medicine, in accordance with the Royal Order of 23 February 1963 laying down General Regulations for Protection of the Population and Workers against the Hazards of Ionizing Radiation. (NEA) [fr

  3. Radiation Practices. Annual report 2004

    International Nuclear Information System (INIS)

    Rantanen, E.

    2005-06-01

    A total of 1791 safety licences for the use of radiation were current at the end of 2004. There were 1924 responsible parties engaged in licence-exempt dental X-ray practices, made notifiable to STUK. Regulatory control of the use of radiation was carried out through regular inspections performed at places of use, test packages sent by post to dental X-ray facilities and maintenance of a Dose Register. Radiation safety guides were also published and research was conducted to support the regulatory control. In 2004, STUK conducted 438 inspections of licensed practices and 38 inspections of notifiable licence-exempt dental X-ray practices. Restrictions were imposed on the use of five appliances. Repairs were ordered in 150 inspections and recommended in 85 inspections. No remarks were given in 229 inspections. A total of 11 082 workers engaged in radiation work were subject to individual monitoring in 2004. 135 000 dose entries were made in the register maintained by STUK. In no case did the individual dose of any worker exceed the dose limits stipulated in the Radiation Decree. Regulatory control of natural radiation concentrated on radon at workplaces and exposure of aircrews to cosmic radiation. At the end of 2004, 55 workplaces including a total of 74 work areas were subject to radon monitoring. A total of 2540 pilots and cabin crew members were monitored for exposure to cosmic radiation. Metrological activities continued with calibration and development work as in previous years. Regulatory control of the use of non-ionizing radiation focused particularly on mobile phones and sunbeds. Radiation safety assessments were also made for public broadcasting equipment, radars, 'artificial sun' aboard a cruise liner, UVC bactericide lamps in a bakery and show laser lights. A recommendation on radiation safety for sunbeds was prepared in association with other Nordic countries. Most research and development work was done in jointly financed research projects and

  4. Study of radiation shielding requirements for n-MOS devices on the Exosat spacecraft. Final report

    International Nuclear Information System (INIS)

    1977-01-01

    The device-degradation and radiation-shielding problems presented by the probable use of an n-channel microprocessor integrated circuit of the 8080 type on the Exosat spacecraft of the European Space Agency, was studied. The radiation exposure likely for this device was calculated, using various assumptions for the amount of surrounding absorber, some being intentional shielding others being normal structure elements and device encapsulation. The conclusion was that this type of device could be used if careful engineering design and quality control were used. Mission doses vary between 5000 and 800 rads for various configurations and some patterns of MOS device will tolerate these doses. The use of specially thickened module covers was not recommended, a better method being upgrading device quality and applying internal (local) shielding when necessary and possibly modular addition of external plates in specific directions only. The result of this shielding philosophy would be much greater efficiency in weight use. The further development of a rads (reduction) per gram philosophy was strongly recommended. Throughout, the strong link between mission success and the choice (and control) of the correct MOS manufacturing technology is emphasized and some guidelines on control of manufactured MOS parts (n-channel and complementary type) with respect to tolerance to radiation are given

  5. Developments of radiation safety requirements for the management of radiation devices

    International Nuclear Information System (INIS)

    Lee, Hee Seock; Choi, Jin Ho; Cheong, Yuon Young

    2002-03-01

    The approach of the risk-informed regulatory options was studied to develop the radiation safety requirements for the managements for radiation devices. The task analysis, exposure, accident scenario development, risk analysis, and systematic approach for regulatory options was considered in full, based on the NRC report, 'NUREG/CR-6642', and the translation of its core part was conducted for ongoing research. In this methodology, the diamond tree that includes human factors, etc, additionally with normal event tree, was used. According to the analysis results of this approach, the risk analysis and the development of regulatory options were applied for the electron linear accelerators and the qualitative results were obtained. Because the field user groups were participated in this study could contribute to the basis establishment of the risk-informed regulation policy through securing consensus and inducing particle interests. It will make an important role of establishing the detail plan of ongoing research

  6. Developments of radiation safety requirements for the management of radiation devices

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hee Seock [Pohang Accelerator Lab, Pohang (Korea, Republic of); Choi, Jin Ho [Gachun University of Medicine and science, Incheon (Korea, Republic of); Cheong, Yuon Young [Asan Medical Center, Seoul (Korea, Republic of)] (and others)

    2002-03-15

    The approach of the risk-informed regulatory options was studied to develop the radiation safety requirements for the managements for radiation devices. The task analysis, exposure, accident scenario development, risk analysis, and systematic approach for regulatory options was considered in full, based on the NRC report, 'NUREG/CR-6642', and the translation of its core part was conducted for ongoing research. In this methodology, the diamond tree that includes human factors, etc, additionally with normal event tree, was used. According to the analysis results of this approach, the risk analysis and the development of regulatory options were applied for the electron linear accelerators and the qualitative results were obtained. Because the field user groups were participated in this study could contribute to the basis establishment of the risk-informed regulation policy through securing consensus and inducing particle interests. It will make an important role of establishing the detail plan of ongoing research.

  7. A new XUV optical end-station to characterize compact and flexible photonic devices using synchrotron radiation

    Science.gov (United States)

    Marcelli, A.; Mazuritskiy, M. I.; Dabagov, S. B.; Hampai, D.; Lerer, A. M.; Izotova, E. A.; D'Elia, A.; Turchini, S.; Zema, N.; Zuccaro, F.; de Simone, M.; Javad Rezvani, S.; Coreno, M.

    2018-03-01

    In this contribution we present the new experimental end-station to characterize XUV diffractive optics, such as Micro Channel Plates (MCPs) and other polycapillary optics, presently under commission at the Elettra synchrotron radiation laboratory (Trieste, Italy). To show the opportunities offered by these new optical devices for 3rd and 4th generation radiation sources, in this work we present also some patterns collected at different energies of the primary XUV radiation transmitted by MCP optical devices working in the normal incidence geometry.

  8. Medical Device Recalls in Radiation Oncology: Analysis of US Food and Drug Administration Data, 2002-2015.

    Science.gov (United States)

    Connor, Michael J; Tringale, Kathryn; Moiseenko, Vitali; Marshall, Deborah C; Moore, Kevin; Cervino, Laura; Atwood, Todd; Brown, Derek; Mundt, Arno J; Pawlicki, Todd; Recht, Abram; Hattangadi-Gluth, Jona A

    2017-06-01

    To analyze all recalls involving radiation oncology devices (RODs) from the US Food and Drug Administration (FDA)'s recall database, comparing these with non-radiation oncology device recalls to identify discipline-specific trends that may inform improvements in device safety. Recall data on RODs from 2002 to 2015 were sorted into 4 product categories (external beam, brachytherapy, planning systems, and simulation systems). Outcomes included determined cause of recall, recall class (severity), quantity in commerce, time until recall termination (date FDA determines recall is complete), and time since 510(k) approval. Descriptive statistics were performed with linear regression of time-series data. Results for RODs were compared with those for other devices by Pearson χ 2 test for categorical data and 2-sample Kolmogorov-Smirnov test for distributions. There were 502 ROD recalls and 9534 other class II device recalls during 2002 to 2015. Most recalls were for external beam devices (66.7%) and planning systems (22.9%), and recall events peaked in 2011. Radiation oncology devices differed significantly from other devices in all recall outcomes (P≤.04). Recall cause was commonly software related (49% vs 10% for other devices). Recall severity was more often moderate among RODs (97.6% vs 87.2%) instead of severe (0.2% vs 4.4%; Panalysis of recall data can identify areas for device improvement, such as better system design among RODs. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Overview of a benefit/risk ratio optimized for a radiation emitting device used in non-destructive testing

    Energy Technology Data Exchange (ETDEWEB)

    Maharaj, H.P., E-mail: H_P_Maharaj@hc-sc.gc.ca [Health Canada, Dept. of Health, Consumer and Clinical Radiaton Protection Bureau, Ottawa, Ontario (Canada)

    2016-03-15

    This paper aims to provide an overview of an optimized benefit/risk ratio for a radiation emitting device. The device, which is portable, hand-held, and open-beam x-ray tube based, is utilized by a wide variety of industries for purposes of determining elemental or chemical analyses of materials in-situ based on fluorescent x-rays. These analyses do not cause damage or permanent alteration of the test materials and are considered a non-destructive test (NDT). Briefly, the key characteristics, principles of use and radiation hazards associated with the Hay device are presented and discussed. In view of the potential radiation risks, a long term strategy that incorporates risk factors and guiding principles intended to mitigate the radiation risks to the end user was considered and applied. Consequently, an operator certification program was developed on the basis of an International Standards Organization (ISO) standard (ISO 20807:2004) and in collaboration with various stake holders and was implemented by a federal national NDT certification body several years ago. It comprises a written radiation safety examination and hands-on training with the x-ray device. The operator certification program was recently revised and the changes appear beneficial. There is a fivefold increase in operator certification (Levels 1 a nd 2) to date compared with earlier years. Results are favorable and promising. An operational guidance document is available to help mitigate radiation risks. Operator certification in conjunction with the use of the operational guidance document is prudent, and is recommended for end users of the x-ray device. Manufacturers and owners of the x-ray devices will also benefit from the operational guidance document. (author)

  10. Overview of a benefit/risk ratio optimized for a radiation emitting device used in non-destructive testing

    International Nuclear Information System (INIS)

    Maharaj, H.P.

    2016-01-01

    This paper aims to provide an overview of an optimized benefit/risk ratio for a radiation emitting device. The device, which is portable, hand-held, and open-beam x-ray tube based, is utilized by a wide variety of industries for purposes of determining elemental or chemical analyses of materials in-situ based on fluorescent x-rays. These analyses do not cause damage or permanent alteration of the test materials and are considered a non-destructive test (NDT). Briefly, the key characteristics, principles of use and radiation hazards associated with the Hay device are presented and discussed. In view of the potential radiation risks, a long term strategy that incorporates risk factors and guiding principles intended to mitigate the radiation risks to the end user was considered and applied. Consequently, an operator certification program was developed on the basis of an International Standards Organization (ISO) standard (ISO 20807:2004) and in collaboration with various stake holders and was implemented by a federal national NDT certification body several years ago. It comprises a written radiation safety examination and hands-on training with the x-ray device. The operator certification program was recently revised and the changes appear beneficial. There is a fivefold increase in operator certification (Levels 1 a nd 2) to date compared with earlier years. Results are favorable and promising. An operational guidance document is available to help mitigate radiation risks. Operator certification in conjunction with the use of the operational guidance document is prudent, and is recommended for end users of the x-ray device. Manufacturers and owners of the x-ray devices will also benefit from the operational guidance document. (author)

  11. Thermal management in MoS{sub 2} based integrated device using near-field radiation

    Energy Technology Data Exchange (ETDEWEB)

    Peng, Jiebin [Department of Physics, National University of Singapore, Singapore 117546 (Singapore); Zhang, Gang, E-mail: zhangg@ihpc.a-star.edu.sg [Institute of High Performance Computing, A*STAR, Singapore 138632 (Singapore); Li, Baowen [Department of Mechanical Engineering, University of Colorado, Boulder, Colorado 80309 (United States)

    2015-09-28

    Recently, wafer-scale growth of monolayer MoS{sub 2} films with spatial homogeneity is realized on SiO{sub 2} substrate. Together with the latest reported high mobility, MoS{sub 2} based integrated electronic devices are expected to be fabricated in the near future. Owing to the low lattice thermal conductivity in monolayer MoS{sub 2}, and the increased transistor density accompanied with the increased power density, heat dissipation will become a crucial issue for these integrated devices. In this letter, using the formalism of fluctuation electrodynamics, we explored the near-field radiative heat transfer from a monolayer MoS{sub 2} to graphene. We demonstrate that in resonance, the maximum heat transfer via near-field radiation between MoS{sub 2} and graphene can be ten times higher than the in-plane lattice thermal conduction for MoS{sub 2} sheet. Therefore, an efficient thermal management strategy for MoS{sub 2} integrated device is proposed: Graphene sheet is brought into close proximity, 10–20 nm from MoS{sub 2} device; heat energy transfer from MoS{sub 2} to graphene via near-field radiation; this amount of heat energy then be conducted to contact due to ultra-high lattice thermal conductivity of graphene. Our work sheds light for developing cooling strategy for nano devices constructing with low thermal conductivity materials.

  12. Underwater radiation measuring device

    International Nuclear Information System (INIS)

    Seki, Noriyuki; Suzuki, Yasuo

    1998-01-01

    The present invention provides a device for measuring, under water, radiation from spent fuels (long members to be detected) of nuclear power plants and reprocessing facilities. Namely, a detecting insertion tube (insertion tube) is disposed so as to be in parallel with axial direction of the long member to be detected stored underwater. A γ-ray detector is inserted to the inside of the insertion tube. A driving mechanism is disposed for moving the γ-ray detector in axial direction inside of the insertion tube. The driving mechanism preferably has a system that it moves the γ-ray detector by winding a detection signal cable around a driving drum. The driving mechanism is formed by inserting and securing a driving tube having screws formed on the side surface and inserting it into the insertion tube. It may have a system of moving the γ-ray detector together with the driving tube while engaging the teeth of a driving transfer mechanism with the screws of the driving tube. (I.S.)

  13. Radiation transmission type pipe wall thinning detection device and measuring instruments utilizing ionizing radiation

    International Nuclear Information System (INIS)

    Higashi, Yasuhiko

    2009-01-01

    We developed the device to detect thinning of pipe thorough heat insulation in Power Plant, etc, even while the plant is under operation. It is necessary to test many parts of many pipes for pipe wall thinning management, but it is difficult within a limited time of the routine test. This device consists of detector and radiation source, which can detect the pipe (less than 500 mm in external diameter, less than 50 mm in thickness) with 1.6%-reproducibility (in a few-minutes measurement), based on the attenuation rate. Operation is easy and effective without removing the heat insulation. We will expand this thinning detection system, and contribute the safety of the Plant. (author)

  14. Improvements to a neutral radiation detection and position sensitive process and devices

    International Nuclear Information System (INIS)

    Charpak, Georges; Nguyen, N.H.; Policarpo, Armando.

    1977-01-01

    This invention aims to provide a neutral radiation position sensitive process and device providing a spatial radiation satisfactory for most medical applications and an energy radiation that cannot be reached by gas detectors based on proportional counters or by scintillation counters. Only solid state detectors can compete with respect to energy resolution. The detector described enables large areas to be covered which cannot be reached at accessible costs by solid state detectors. With this aim in view, the invention suggests an incident neutral radiation and position sensitive process, particularly soft gamma and X radiations, whereby photoelectrons are made to form by incident radiation action on gas atoms contained in an enclosure. By means of an electric field, the electrons are diverted towards a space undergoing an electric field high enough in value to create photons by exciting gas atoms and returning them to the de-excited state. The photons are collected, through a transparent window, on a layer of a material for converting such photons into scintillations in the near or visible UV spectrum and the barycentre of the scintillations is positioned on the layer, for instance by photomultipliers or ionization detectors. According to another aspect of the invention, it suggests a detection and position sensitive device comprising (generally downstream of a collimator with a grid of inlet holes) a leak tight containment fitted with an inlet window transparent to incident radiations, filled with a gas producing electrons by interaction with the incident radiation, and fitted with electrodes for generating an electric field to divert the electrons to a space for creating secondary photons [fr

  15. Emergency response activities and collecting damaged radiation devices from a war affected area in Croatia

    International Nuclear Information System (INIS)

    Subasic, Damir; Schaller, Antum

    1997-01-01

    A number of various devices containing ionizing radiation sources were in use in the area affected by the recent war in Croatia. In destruction caused by the war operations, a number of these devices were damaged, destroyed or even missed/lost. The actions undertaken to (re)collect these radiation sources, experience gained and lessons learned are reviewed. The importance of a well-organized national regulatory system is highlighted as a precondition for the efficient identification and safe collection of radiation sources which were under ruins. Experience from this event could be well applicable to similar situations caused by disasters and particularly for regulatory authorities who design emergency preparedness plans. (author)

  16. Application of Nd/sup 3+/-doped silica fibers to radiation sensing devices

    International Nuclear Information System (INIS)

    Imamura, K.; Suzuki, T.; Gozen, T.; Tanaka, H.; Okamoto, S.

    1987-01-01

    Applications of rare-earth-ion-doped optical fibers to radiation sensing devices have been studied. It was revealed that rare-earth-ion-doped optical fibers are highly sensitive to radioactive rays such as gamma ray and thermal neutron flux and that they have little dependence on ambient temperature and optical power. An experimental distributed radiation sensing system incorporating Nd/sup 3+/-doped optical fibers, radiation resistant optical fibers and an OTDR was made and tested. The results proved that the distributed sensing system is practically adaptable to the measurement of the radioactive rays

  17. Radiation shielding device

    International Nuclear Information System (INIS)

    Nakagawa, Takahiro; Yamagami, Makoto.

    1996-01-01

    A fixed shielding member made of a radiation shielding material is constituted in perpendicular to an opening formed on radiation shielding walls. The fixed shielding member has one side opened and has other side, the upper portion and the lower portion disposed in close contact with the radiation shielding walls. Movable shielding members made of a radiation shielding material are each disposed openably on both side of the fixed shielding member. The movable shielding member has a shaft as a fulcrum on one side thereof for connecting it to the radiation shielding walls. The other side has a handle attached for opening/closing the movable shielding member. Upon access of an operator, when each one of the movable shielding members is opened/closed on every time, leakage of linear or scattered radiation can be prevented. Even when both of the movable shielding members are opened simultaneously, the fixed shielding member and the movable shielding members form labyrinth to prevent leakage of linear radioactivity. (I.N.)

  18. Radiation effects and hardness of semiconductor electronic devices for nuclear industry

    International Nuclear Information System (INIS)

    Payat, R.; Friant, A.

    1988-01-01

    After a brief review of industrial and nuclear specificity and radiation effects in electronics components (semiconductors) the need for a specific test methodology of semiconductor devices is emphasized. Some studies appropriate for nuclear industry at D. LETI/DEIN/CEN-SACLAY are related [fr

  19. Ultraviolet spectral distribution and erythema-weighted irradiance from indoor tanning devices compared with solar radiation exposures.

    Science.gov (United States)

    Sola, Yolanda; Baeza, David; Gómez, Miguel; Lorente, Jerónimo

    2016-08-01

    Concern regarding the impact of indoor tanning devices on human health has led to different regulations and recommendations, which set limits on erythema-weighted irradiance. Here, we analyze spectral emissions from 52 tanning devices in Spanish facilities and compare them with surface solar irradiance for different solar zenith angles. Whereas most of the devices emitted less UV-B radiation than the midday summer sun, the unweighted UV-A irradiance was 2-6 times higher than solar radiation. Moreover, the spectral distributions of indoor devices were completely different from that of solar radiation, differing in one order of magnitude at some UV-A wavelengths, depending on the lamp characteristics. In 21% of the devices tested, the erythema-weighted irradiance exceeded 0.3Wm(-2): the limit fixed by the European standard and the Spanish regulation. Moreover, 29% of the devices fall within the UV type 4 classification, for which medical advice is required. The high variability in erythema-weighted irradiance results in a wide range of exposure times to reach 1 standard erythemal dose (SED: 100Jm(-2)), with 62% of devices requiring exposures of UV-A dose during this time period would be from 1.4 to 10.3 times more than the solar UV-A dose. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Utilization of photoconductive gain in a-Si:H devices for radiation detection

    International Nuclear Information System (INIS)

    Lee, H.K.; Drewery, J.S.; Hong, W.S.; Jing, T.; Kaplan, S.N.; Perez-Mendez, V.

    1995-05-01

    The photoconductive gain mechanism in a-Si:H was investigated in connection with applications to radiation detection. Various device types such as p-i-n, n-i-n and n-i-p-i-n structures were fabricated and tested. Photoconductive gain was measured in two time scales: one for short pulses of visible light ( 2 . Various gain results are discussed in terms of the device structure, applied bias and dark current

  1. Application of complex programmable logic devices in memory radiation effects test system

    International Nuclear Information System (INIS)

    Li Yonghong; He Chaohui; Yang Hailiang; He Baoping

    2005-01-01

    The application of the complex programmable logic device (CPLD) in electronics is emphatically discussed. The method of using software MAX + plus II and CPLD are introduced. A new test system for memory radiation effects is established by using CPLD devices-EPM7128C84-15. The old test system's function are realized and, moreover, a number of small scale integrated circuits are reduced and the test system's reliability is improved. (authors)

  2. Social Licence to Operate through a gender lens : The challenges of including women’s interests in development assistance projects

    NARCIS (Netherlands)

    Jijelava, David; Vanclay, Frank

    2014-01-01

    The paper analyses the concept of social licence to operate from a gender perspective. We examine the challenges associated with obtaining a gender-aware social licence for development assistance organizations working in conservative, traditional rural societies. We argue that during project

  3. Possibilities of radiation sterilization for re-usage of medical devices in the medical management

    International Nuclear Information System (INIS)

    Tabei, Masae; Kudo, Hisaaki; Katsumura, Yosuke

    2004-01-01

    The rule for re-usage of medical single-use devices was established in US in 2000 based on the concept of Managed Care (total management of medicare on cost, quality and patients' satisfaction) and 20-30% of those devices are re-used at present. The re-usage is conducted in not only US but also Canada, Denmark, UK, India, China etc. Standing on the viewpoint, this paper described and discussed the possibility of re-usage of the single-use devices now prohibited in Japan, possible re-sterilization, possible re-usage of hollow fiber-type hemodialyzer following γ-ray sterilization with consideration for D-values against bacteria and viruses, cost estimation of electron beam sterilization for re-usage, and radiation sterilization of waste water and plastic materials. Radiation sterilization for re-usage of medical devices was concluded possible if their materials and records for their usage processes are proper, and should be conducted in a large scale after sufficient examinations by industries/government/academia. (N.I.)

  4. Response of Caenorhabditis elegans to wireless devices radiation exposure.

    Science.gov (United States)

    Fasseas, Michael K; Fragopoulou, Adamantia F; Manta, Areti K; Skouroliakou, Aikaterini; Vekrellis, Konstantinos; Margaritis, Lukas H; Syntichaki, Popi

    2015-03-01

    To examine the impact of electromagnetic radiation, produced by GSM (Global System for Mobile communications) mobile phones, Wi-Fi (Wireless-Fidelity) routers and wireless DECT (Digital Enhanced Cordless Telecommunications) phones, on the nematode Caenorhabditis elegans. We exposed synchronized populations, of different developmental stages, to these wireless devices at E-field levels below ICNIRP's (International Commission on Non-Ionizing Radiation Protection) guidelines for various lengths of time. WT (wild-type) and aging- or stress-sensitive mutant worms were examined for changes in growth, fertility, lifespan, chemotaxis, short-term memory, increased ROS (Reactive Oxygen Species) production and apoptosis by using fluorescent marker genes or qRT-PCR (quantitative Reverse Transcription-Polymerase Chain Reaction). No statistically significant differences were found between the exposed and the sham/control animals in any of the experiments concerning lifespan, fertility, growth, memory, ROS, apoptosis or gene expression. The worm appears to be robust to this form of (pulsed) radiation, at least under the exposure conditions used.

  5. Heat resistant/radiation resistant cable and incore structure test device for FBR type reactor

    International Nuclear Information System (INIS)

    Tanimoto, Hajime; Shiono, Takeo; Sato, Yoshimi; Ito, Kazumi; Sudo, Shigeaki; Saito, Shin-ichi; Mitsui, Hisayasu.

    1995-01-01

    A heat resistant/radiation resistant coaxial cable of the present invention comprises an insulation layer, an outer conductor and a protection cover in this order on an inner conductor, in which the insulation layer comprises thermoplastic polyimide. In the same manner, a heat resistant/radiation resistant power cable has an insulation layer comprising thermoplastic polyimide on a conductor, and is provided with a protection cover comprising braid of alamide fibers at the outer circumference of the insulation layer. An incore structure test device for an FBR type reactor comprises the heat resistant/radiation resistant coaxial cable and/or the power cable. The thermoplastic polyimide can be extrusion molded, and has excellent radiation resistant by the extrusion, as well as has high dielectric withstand voltage, good flexibility and electric characteristics at high temperature. The incore structure test device for the FBR type reactor of the present invention comprising such a cable has excellent reliability and durability. (T.M.)

  6. The use of ionising radiation screening devices in airports

    International Nuclear Information System (INIS)

    Lazo, T.

    2010-01-01

    Although the NEA generally focuses on radiological protection at nuclear power plants and related facilities, it also addresses other areas of radiological protection of interest to member countries. A particular subject of recent importance concerns the use of ionising radiation screening devices as part of airport security efforts. Modern body scanners can produce human images that can be used to detect weapons that may be hidden beneath a person's clothing. Heightened concerns over terrorist threats to airline flights have prompted many countries to consider the use, or expanded use of body scanners. The use of such devices raises a wide series of questions, some of which concern the radiological protection of those who might be scanned. As such, the Inter-Agency Committee on Radiation Safety (IACRS), an expert body in which the NEA works together with several other international organisations addressing radiological protection issues, recently developed a joint information paper laying out the key radiological protection and other issues that should be or have been considered when making decisions as to whether ionising radiation body scanners should be deployed in airports. This article provides an overview of the information paper. In assessing the possible use of X-ray body scanners, there are two significant radiological protection issues that may be of relevance with regard to the government decision whether their use is justified. First, although the individual exposures are very low, the exposure experienced by the scanned population as a whole will depend on whether all passengers are systematically scanned, or alternatively whether passengers are selected for scanning randomly or on the basis of specific criteria. The manner in which passengers would be selected would need to be known in order to appropriately assess the full radiological protection impact of scanner use. Second, the use of X-ray body scanners on sensitive groups, such as pregnant

  7. How do user experiences with different transport modes affect the risk of traffic accidents? From the viewpoint of licence possession status.

    Science.gov (United States)

    Nakai, Hiroshi; Usui, Shinnosuke

    2017-02-01

    Road accidents between different modes of transport-such as between automobiles and pedestrians, automobiles and bicycles, or automobiles and motorcycles-are frequent. In such cases, it is important to consider the other side's perspective. This involves the ability to correctly judge, for every given situation, how other people on the road perceive their surroundings and what they intend to do next. In this paper, we conduct two types of studies assuming that this kind of ability to consider perspectives is higher when the person is licenced to drive the mode of transport used by the other party. For Study 1, we analysed accidents involving senior citizens between the ages of 65 and 74 years, who collided with automobiles as pedestrians or cyclists (1656 and 3192 cases respectively), in terms of the accident category and type of road at the accident spot. The results indicate that possession or non-possession of a licence was irrelevant for accidents involving cyclists, but for accidents with pedestrians, senior citizens who did not possess a licence are likely to be involved in a greater number of accidents in places that require interaction with automobiles, such as while crossing at crosswalks or at intersections. For Study 2, we reviewed 875 ordinary first-class licence practical test examinees, categorised them according to their licence possession status (motorcycle licence, moped licence, or no licence), and made a category-wise comparison of the test instructor's assessment of their ability to make a left turn. The results showed that those who had a motorcycle or moped licence tended to make a left turn more safely. Thus, the results indicate that experience with different modes of transport is likely to reduce the risk of accidents. These findings may be used to popularise educational interventions encouraging users of various transport modes to consider the perspective of others (i.e. via perspective-taking). Copyright © 2016 Elsevier Ltd. All rights

  8. Radiation control act 1990 no. 13 (7/6/1990) New South Wales

    International Nuclear Information System (INIS)

    1990-01-01

    The object of the Act is to ensure the protection of persons and the environment against exposure to ionizing radiation and harmful non-ionizing radiation, taking into account social and economic factors and recognising that radiation is needed for therapeutic purposes. The Act regulates and controls the sale, use, keeping and disposal of radioactive substances and radiation apparatus, but does not apply to radioactive ores as defined by the Mines Inspection Act 1901. It provides for a licensing system for such substances and apparatus, the licensing authority being the Director-General of the Department of Health, under the overall authority of the Minister for Health. No person may sell or use the substances or apparatus without a licence granted by the Director-General. A licence is granted only following the recommendation of the Radiation Advisory Council set up under this Act [fr

  9. Emergency response activities and collecting damaged radiation devices from a war affected area in Croatia

    Energy Technology Data Exchange (ETDEWEB)

    Subasic, Damir; Schaller, Antum [APO-Hazardous Waste Management Agency, Zagreb (Croatia)

    1997-12-31

    A number of various devices containing ionizing radiation sources were in use in the area affected by the recent war in Croatia. In destruction caused by the war operations, a number of these devices were damaged, destroyed or even missed/lost. The actions undertaken to (re)collect these radiation sources, experience gained and lessons learned are reviewed. The importance of a well-organized national regulatory system is highlighted as a precondition for the efficient identification and safe collection of radiation sources which were under ruins. Experience from this event could be well applicable to similar situations caused by disasters and particularly for regulatory authorities who design emergency preparedness plans. (author) 4 refs., 1 tab.

  10. Determination of the permeability of α-, β- and γ-radiation in textile fabrics by Gamma-Scout device

    International Nuclear Information System (INIS)

    Gintibidze, N.; Mardaleishvili, Z.

    2009-01-01

    The goal of the present was the measurement of radiation permeability in textile fabrics by Gamma-Scout device and the comparison of the obtained results with the radiation background of the ambient air. The authors of this article have produced new fiber Fibron-3, which, according to theoretical calculations, reduces permeability of solar radiation. With this in mind, an experiment was performed. Three samples of the knitted cloth from Fibron-3 were taken, and the permeability of solar radiation in them was determined. The measurements were performed on Gamma-Scout device. The comparative analysis of the permeability of solar radiation in fabrics of different fibrous structure was performed. It was inferred that the degree of radiation permeability in fabrics depended on the thread thickness and the fiber structure. (author)

  11. Synchrotron radiation A general overview and a review of storage rings, research facilities, and insertion devices

    International Nuclear Information System (INIS)

    Winick, H.

    1989-01-01

    Synchrotron radiation, the electromagnetic radiation given off by electrons in circular motion, is revolutionizing many branches of science and technology by offering beams of vacuum ultraviolet light and x rays of immense flux and brightness. In the past decade there has been an explosion of interest in these applications leading activity to construct new research facilities based on advanced storage rings and insertion device sources. Applications include basic and applied research in biology, chemistry, medicine, and physics plus many areas of technology. In this article we present a general overview of the field of synchrotron radiation research, its history, the present status and future prospects of storage rings and research facilities, and the development of wiggler and undulator insertion devices as sources of synchrotron radiation

  12. Linear devices in combined high-level radiation environments

    International Nuclear Information System (INIS)

    van Vonno, N.W.

    1987-01-01

    The design of precision analog integrated circuits for use in combined high-level radiation environments has traditionally been on a full-custom basis. The use of semicustom design methods has become prevalent in digital devices, with standard cell libraries and gate arrays readily available from multiple vendors. This paper addresses the application of semicustom design techniques to analog parts. In all cases the emphasis is on bipolar technology, since this provides an optimal combination of precision and radiation hardness. A mixed mode analog/digital (A/D) cell family for implementing semicustom designs is described, together with the fabrication process used. Specific processing and design methods are used to provide circuit hardness against neutron, total gamma dose, and transient gamma environments. Semicustom mixed analog/digital design is seen as an appropriate methodology for implementation of medium-performance mixed mode functions for radiation-hardened applications. This leads to trade-offs in process complexity and performance. Full custom design remains necessary for demanding applications such as high-speed A/D conversion and associated sample/hold functions. An A/D cell family optimized for hardness is described, together with the bipolar process used to implement it

  13. Radiation leaking protection device

    International Nuclear Information System (INIS)

    Sunami, Yoshio; Mitsumori, Kojiro

    1980-01-01

    Purpose: To prevent radioactivity from leaking outside of a reactor container by way of pipeways passing therethrough, by supplying pressurized fluid between each of a plurality of valves for separating the pipeways. Constitution: Pressurized fluid is supplied between each of a plurality of valves for separating pipeways. For instance, water in a purified water tank is pressurized by a pressure pump and the pressure of the pressurized water is controlled by a differential pressure detector, a pressure controller and a pressure control valve. In the case if a main steam pipe is ruptured outside of the reactor container or to be repaired, the separation valves are wholly closed and then the pressurizing device is actuated to supply pressurized water containing no radioactivity from the purified water tank to the position between the valves. The pressure in the pressurized water is controlled such that it is always higher by a predetermined level than the pressure in the reactor. This prevents the radioacitivity in the reactor core from leaking outside of the container passing through the valves, whereby radiation exposure in the working can be reduced and the circumferential contamination upon accident of pipeway rupture can be decreased. (Kawakami, Y.)

  14. Malfunction of cardiac devices after radiotherapy without direct exposure to ionizing radiation: mechanisms and experimental data.

    Science.gov (United States)

    Zecchin, Massimo; Morea, Gaetano; Severgnini, Mara; Sergi, Elisabetta; Baratto Roldan, Anna; Bianco, Elisabetta; Magnani, Silvia; De Luca, Antonio; Zorzin Fantasia, Anna; Salvatore, Luca; Milan, Vittorino; Giannini, Gianrossano; Sinagra, Gianfranco

    2016-02-01

    Malfunctions of cardiac implantable electronical devices (CIED) have been described after high-energy radiation therapy even in the absence of direct exposure to ionizing radiation, due to diffusion of neutrons (n) causing soft errors in inner circuits. The purpose of the study was to analyse the effect of scattered radiation on different types and models of CIED and the possible sources of malfunctions. Fifty-nine explanted CIED were placed on an anthropomorphous phantom of tissue-equivalent material, and a high-energy photon (15 MV) radiotherapy course (total dose = 70 Gy) for prostate treatment was performed. All devices were interrogated before and after radiation. Radiation dose, the electromagnetic field, and neutron fluence at the CIED site were measured. Thirty-four pacemakers (PM) and 25 implantable cardioverter-defibrillators (ICD) were analysed. No malfunctions were detected before radiation. After radiation a software malfunction was evident in 13 (52%) ICD and 6 (18%) PM; no significant electromagnetic field or photon radiations were detected in the thoracic region. Neutron capture was demonstrated by the presence of the (198)Au((197)Au + n) or (192)Ir((191)Ir + n) isotope activation; it was significantly greater in ICD than in PM and non-significantly greater in damaged devices. A greater effect in St Jude PM (2/2 damaged), Boston (9/11), and St Jude ICD (3/6) and in older ICD models was observed; the year of production was not relevant in PM. High-energy radiation can cause different malfunctions on CIED, particularly ICD, even without direct exposure to ionizing radiation due to scattered radiation of neutrons produced by the linear accelerator. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  15. A comparison of ionizing radiation damage in CMOS devices from 60Co gamma rays, electrons and protons

    International Nuclear Information System (INIS)

    He Baoping; Yao Zhibin; Zhang Fengqi

    2009-01-01

    Radiation hardened CC4007RH and non-radiation hardened CC4011 devices were irradiated using 60 Co gamma rays, 1 MeV electrons and 1-9 MeV protons to compare the ionizing radiation damage of the gamma rays with the charged particles. For all devices examined, with experimental uncertainty, the radiation induced threshold voltage shifts (ΔV th ) generated by 60 Co gamma rays are equal to that of 1 MeV electron and 1-7 MeV proton radiation under 0 gate bias condition. Under 5 V gate bias condition, the distinction of threshold voltage shifts (ΔV th ) generated by 60 Co gamma rays and 1 MeV electrons irradiation are not large, and the radiation damage for protons below 9 MeV is always less than that of 60 Co gamma rays. The lower energy the proton has, the less serious the radiation damage becomes. (authors)

  16. Research on dose setting for radiation sterilization of medical device

    International Nuclear Information System (INIS)

    Zhang Tongcheng; Liu Qingfang; Zhong Hongliang; Mi Zhisu; Wang Chunlei; Jiang Jianping

    2002-01-01

    Objective: To establish the radiation sterilization dose for medical devices using data of bioburden on the medical device. Methods: Firstly determination of recovery ratio and correction coefficient of the microbiological test method was used according to ISO11737 standard, then determination of bioburden on the products, finally the dose setting was completed based on the Method 1 in ISO11137 standard. Results: Fifteen kinds of medical devices were tested. Bioburden range was from 8.6-97271.2 CFU/device, recovery ration range 54.6%-100%, correction co-efficiency range 1.00-1.83, D 10 distribution from 1.40 to 2.82 kGy, verification dose (dose at SAL = 10 -2 ) range 5.1-17.6 kGy and sterilization dose (dose at SAL 10 -6 ) range 17.5-32.5 kGy. Conclusion: One hundred samples of each kind of product were exposed to the pre-determined verification dose and then the sterility test was performed. Each sterility test showed positive number was not greater than two. This indicated that the sterilization dose established for each kind of product was statistically acceptable

  17. Ordinance of 17 May 1978 on definitions and licences in the atomic energy field

    International Nuclear Information System (INIS)

    1978-01-01

    This Ordinance came into force on 1 July 1978. It enables the Swiss authorities to apply the provisions of the Treaty on the Non-Proliferation of Nuclear Weapons and the guidelines on the transfer of nuclear material and equipment of the group of nuclear supplier countries (London Club) according to the IAEA document INFCIRC 254. The Ordinance is supplemented by annexes and appendices which list and specify the material, reactors and equipment which are subject to an export licence. The Federal Office of Energy Economy issues the licences required for the import and export of such material and equipment. Finally, this Ordinance repeals the Ordinance of 13 June 1960 on Definitions and Permits in the Atomic Energy Field. (NEA) [fr

  18. Thermal and radiation losses in a linear device

    International Nuclear Information System (INIS)

    Rosenau, P.; Degani, D.

    1980-01-01

    An analysis is presented of the electron temperature in a linear device which includes the effect of thermal conduction, heat flux limit, radiation, and end plugs. It is found that the thermal conduction and the heat flux limit are dominant in the initial phase of cooling, while the later phase is almost completely controlled by radiation that spatially homogenizes the temperature distribution. In the case of bremsstrahlung, within the frame of the present model, the temperature decays to zero in a finite time. This process takes the form of a cooling wave that moves from the ends of the column to the center. Impurities cause a milder, exponential decay, which is still much faster than the algebraic conduction decay. The thermal effectiveness of the end plugs is described by a convective transfer coefficient h/sub p/. Its scaling law (in terms of the coupled plamsa-plug system) reveals that a very high plug-plasma density ratio provides a simple way to significantly retard the cooling

  19. Taking SiC Power Devices to the Final Frontier: Addressing Challenges of the Space Radiation Environment

    Science.gov (United States)

    Lauenstein, Jean-Marie; Casey, Megan

    2017-01-01

    Silicon carbide power device technology has the potential to enable a new generation of aerospace power systems that demand high efficiency, rapid switching, and reduced mass and volume in order to expand space-based capabilities. For this potential to be realized, SiC devices must be capable of withstanding the harsh space radiation environment. Commercial SiC components exhibit high tolerance to total ionizing dose but to date, have not performed well under exposure to heavy ion radiation representative of the on-orbit galactic cosmic rays. Insertion of SiC power device technology into space applications to achieve breakthrough performance gains will require intentional development of components hardened to the effects of these highly-energetic heavy ions. This work presents heavy-ion test data obtained by the authors over the past several years for discrete SiC power MOSFETs, JFETs, and diodes in order to increase the body of knowledge and understanding that will facilitate hardening of this technology to space radiation effects. Specifically, heavy-ion irradiation data taken under different bias, temperature, and ion beam conditions is presented for devices from different manufacturers, and the emerging patterns discussed.

  20. What are the impacts of giving up the driving licence?

    DEFF Research Database (Denmark)

    Siren, Anu Kristiina; Haustein, Sonja

    2014-01-01

    as passengers, used public transport, walked or cycled. Not renewing the licence was a strong predictor of unmet mobility needs, especially in relation to leisure activities. The present study indicates that younger seniors’ mobility is not likely to be affected by the strict renewal policies. However, given...... the positive economic and safety consequences of independent mobility in old age, society should try to prevent unwarranted mobility loss. Having restrictive, ageist policies that moreover fail as societal investments may work against this goal....

  1. Simulating threshold voltage shift of MOS devices due to radiation in the low-dose range

    CERN Document Server

    Wan Xin Heng; Gao Wen Yu; Huang Ru; Wang Yang Yuan

    2002-01-01

    An analytical MOSFET threshold voltage shift model due to radiation in the low-dose range has been developed for circuit simulations. Experimental data in the literature shows that the model predictions are in good agreement. It is simple in functional form and hence computationally efficient. It can be used as a basic circuit simulation tool for analysing MOSFET exposed to a nuclear environment up to about 1 Mrad(Si). In accordance with common believe, radiation induced absolute change of threshold voltage was found to be larger in irradiated PMOS devices. However, if the radiation sensitivity is defined in the way authors did it, the results indicated NMOS rather than PMOS devices are more sensitive, specially at low doses. This is important from the standpoint of their possible application in dosimetry

  2. Design of radiation-chemical devices with gamma source for sewage treatment

    International Nuclear Information System (INIS)

    Mendel'son, Eh.L.; Gol'din, V.A.; Breger, A.Kh.

    1981-01-01

    The semiempirical method of calculating conductivity of radiation- chemical devices (RCD) with γ-sources to purify domestic and industrial drainage waters and other processes in liquid phase systems which meet definite requirements based on taking into account the structure of the technological process, is suggested RCD of a new type is developed. It is coaxially cylindrical. A correcting coefficient which takes into account the difference in the actual time of keeping a current of drainage water in the device and its avaraged calculation value, conditioned by the longtitudinal transfer of a substance in the device, is determined. It is shown that the above RCD productivity can be considerably increased due to creating the structure of adisplacement current which provides the equality of absorbed doses in all its elements [ru

  3. Pre-licensed driving experience and car crash involvement during the learner and restricted, licence stages of graduated driver licensing: Findings from the New Zealand drivers study.

    Science.gov (United States)

    Begg, Dorothy J; Langley, John D; Brookland, Rebecca L; Ameratunga, Shanthi; Gulliver, Pauline

    2014-01-01

    The aim of this study was to determine whether pre-licence driving experiences, that is driving before beginning the licensing process, increased or decreased crash risk as a car driver, during the learner or the restricted licence stages of the graduated driver licensing system (GDLS). Study participants were 15-24 year old members of the New Zealand Drivers Study (NZDS) - a prospective cohort study of newly licensed car drivers. The interview stages of the NZDS are linked to, the three licensing stages of the GDLS: learner, restricted and full. Baseline demographic (age, ethnicity, residential location, deprivation), personality (impulsivity, sensation seeking, aggression) and, behavioural data, (including pre-licensed driving behaviour), were obtained at the learner licence interview. Data on distance driven and crashes that occurred at the learner licence and restricted licence stages, were reported at the restricted and full licence interviews, respectively. Crash data were also obtained from police traffic crash report files and this was combined with the self-reported crash data. The analysis of the learner licence stage crashes, when only supervised driving is allowed, was based on the participants who had passed the restricted licence test and undertaken the NZDS, restricted licence interview (n=2358). The analysis of the restricted licence stage crashes, when unsupervised driving is first allowed, was based on those who had passed the full licence test and completed the full licence interview (n=1428). After controlling for a range of demographic, personality, behavioural variables and distance driven, Poisson regression showed that the only pre-licence driving behaviour that showed a consistent relationship with subsequent crashes was on-road car driving which was associated with an increased risk of being the driver in a car crash during the learner licence period. This research showed that pre-licensed driving did not reduce crash risk among learner or

  4. Chalcogenide Glass Radiation Sensor; Materials Development, Design and Device Testing

    Energy Technology Data Exchange (ETDEWEB)

    Mitkova, Maria; Butt, Darryl; Kozicki, Michael; Barnaby, Hugo

    2013-04-30

    For many decades, various radiation detecting material have been extensively researched, to find a better material or mechanism for radiation sensing. Recently, there is a growing need for a smaller and effective material or device that can perform similar functions of bulkier Geiger counters and other measurement options, which fail the requirement for easy, cheap and accurate radiation dose measurement. Here arises the use of thin film chalcogenide glass, which has unique properties of high thermal stability along with high sensitivity towards short wavelength radiation. The unique properties of chalcogenide glasses are attributed to the lone pair p-shell electrons, which provide some distinctive optical properties when compared to crystalline material. These qualities are derived from the energy band diagram and the presence of localized states in the band gap. Chalcogenide glasses have band tail states and localized states, along with the two band states. These extra states are primarily due to the lone pair electrons as well as the amorphous structure of the glasses. The localized states between the conductance band (CB) and valence band (VB) are primarily due to the presence of the lone pair electrons, while the band tail states are attributed to the Van der Waal's forces between layers of atoms [1]. Localized states are trap locations within the band gap where electrons from the valence band can hop into, in their path towards the conduction band. Tail states on the other hand are locations near the band gap edges and are known as Urbach tail states (Eu). These states are occupied with many electrons that can participate in the various transformations due to interaction with photons. According to Y. Utsugi et. al.[2], the electron-phonon interactions are responsible for the generation of the Urbach tails. These states are responsible for setting the absorption edge for these glasses and photons with energy near the band gap affect these states. We have

  5. 77 FR 41417 - Regulatory Science Considerations for Medical Countermeasure Radiation Biodosimetry Devices

    Science.gov (United States)

    2012-07-13

    ... scientific and technological challenges for performance validation of radiation biodosimetry devices. Date... participants (non-FDA employees) is through Bldg. 1 where routine security check procedures will be performed... this document. FDA will do its best to accommodate requests to make public comment. Individuals and...

  6. Energy Projects, Social Licence, Public Acceptance and Regulatory Systems in Canada: A White Paper

    Directory of Open Access Journals (Sweden)

    John Colton

    2016-05-01

    Full Text Available It has become increasingly difficult in Canada to gain and sustain public acceptance of energy projects. Increased levels of protest, combined with traditional media and social media coverage of opposition, combine to suggest decreased public acceptance of energy projects. Decision-makers have responded accordingly, and a variety of energy projects have either been delayed or put on hold indefinitely. This is true for both conventional and renewable energy projects and in many different regions across the country. A number of proposed energy projects have recently faced opposition from various stakeholder groups. For instance, the decision of the Joint Review Panel for the Northern Gateway Pipeline is being challenged in Canada’s court system. First Nations groups have issued an ultimatum to the Federal Government that it must choose between Site C (a proposed hydro dam and liquefied natural gas development in B.C. Rapid expansion of wind energy projects in Ontario has engendered lengthy and costly appeals and the rise of an anti-wind social movement. In Nova Scotia, tidal energy development is being positioned as a new renewable energy option; gaining public acceptance is critical in light of recent opposition to wind energy development. As these experiences suggest, not only has the regulatory process become more contentious, but also an apparently new concept — social licence — has had popular appeal. This white paper reports on the results of a year-long interdisciplinary collaboration aimed at identifying and summarizing extant research regarding social licence and related concepts, with a particular emphasis on understanding its implications for public acceptance of energy projects in Canada, and their related regulatory processes. In particular, this research addressed the following questions: 1. What is the history and scope of the term ‘social licence’, both in the context of energy project development and more generally? What

  7. Wearable device for monitoring momentary presence of intense x-ray and/or ultra-violet radiations

    International Nuclear Information System (INIS)

    Shriner, W.

    1981-01-01

    A credit-card-size clear-plastic-encased device can be worn or carried by a person to warn him of the momentary presence of dangerous intensities of ultra-violet and/or x-ray radiations. A base lamina (e.g. of cardboard) is coated with a material (e.g. zinc-cadmium sulfide or lead-barium sulfate) which fluoresces under such radiations. Numerals, letters, words or symbols are printed over the fluorescent coat with a material inhibitory to said radiations so that a warning message in dark print will appear on a light background when dangerous intensities of said radiations are present. An x-ray-warning area is covered with an ultra-violet absorbing screen so that said area will glow only under x-rays (Which rays will also activate the remaining ultra-violet-responsive area). The colors of the laminas and the coats are so selected that the messages are not visible when dangerous radiations are not present. If desired, only the message can be printed with fluorescent material so as to glow on a darker background. Optionally, step-layer attenuation devices can be added to indicate degrees of radiation; and reflecting surfaces can underlie the fluorescent coat to increase efficiency and/or sensitively

  8. A study of radiation vulnerability of ferroelectric material and devices

    International Nuclear Information System (INIS)

    Coiec, Y.M.; Musseau, O.; Leray, J.L.

    1994-01-01

    The radiation effects on ferroelectric material and devices are presented, based on commercially available samples. After recalling the background, effects in ferroelectric PZT capacitors are presented, concerning dose, neutrons and fatigue associated with dose effects. Physical implications and interpretations are sketched. In a second stage, effects are studied at the complete non-volatile RAM device level. Vulnerability in dose, dose rate and neutron fluence of commercial 4 kbit ferroelectric RAM is addressed. 64 kbit results are mentioned in dose rate. These results are compared to previously published data from other manufacturers or laboratories and supplement them. In the appendix, equivalence between rad(Si) and rad (PZT) is discussed in the case of low energy ''10 keV Aracor'' x-rays and 60 Co gamma rays

  9. Organization for the use of radiation

    International Nuclear Information System (INIS)

    1993-01-01

    In Finland according to section 18 of the Finnish Radiation Act (592/91), organizations running a radiation practice are required to give a description how the work is arranged when applying for a safety licence, naming the radiation safety officer and providing information about qualifications, tasks and responsibilities of persons involved in the use of radiation, and about other related arrangements. In this guide the organisatory arrangements required for the permission of the use of radiation in Finland are specified. The guide also includes instructions for measures which has to be taken care of in different kinds of use of radiation and the competence requirements for the persons in charge of the radiation safety

  10. First test of WTO mechanism for procuring generic medicines under compulsory licence, via Canada's Access to Medicines Regime.

    Science.gov (United States)

    Elliott, Richard

    2007-12-01

    In July 2007, Rwanda became the first nation to initiate use of a procedure under the rules of the World Trade Organization (WTO) that is supposed to let developing countries import lower-cost, generic medicines produced in other countries under compulsory licences. And two months later, based on Rwanda's initiative, Canada's Commissioner of Patents issued the first compulsory licence under this system to permit the production of a patented AIDS drug to that country.

  11. Evaluation of pelletron accelerator facility to study radiation effects on semiconductor devices

    Energy Technology Data Exchange (ETDEWEB)

    Prakash, A. P. Gnana; Pushpa, N.; Praveen, K. C.; Naik, P. S.; Revannasiddaiah, D. [Department of Studies in Physics, University of Mysore, Manasagangotri, Mysore-570006, Karnataka (India)

    2012-06-05

    In this paper we present the comprehensive results on the effects of different radiation on the electrical characteristics of different semiconductor devices like Si BJT, n-channel MOSFETs, 50 GHz and 200 GHz silicon-germanium heterojunction bipolar transistor (SiGe HBTs). The total dose effects of different radiation are compared in the same total dose ranging from 100 krad to 100 Mrad. We show that the irradiation time needed to reach very high total dose can be reduced by using Pelletron accelerator facilities instead of conventional irradiation facilities.

  12. Evaluation of pelletron accelerator facility to study radiation effects on semiconductor devices

    International Nuclear Information System (INIS)

    Prakash, A. P. Gnana; Pushpa, N.; Praveen, K. C.; Naik, P. S.; Revannasiddaiah, D.

    2012-01-01

    In this paper we present the comprehensive results on the effects of different radiation on the electrical characteristics of different semiconductor devices like Si BJT, n-channel MOSFETs, 50 GHz and 200 GHz silicon-germanium heterojunction bipolar transistor (SiGe HBTs). The total dose effects of different radiation are compared in the same total dose ranging from 100 krad to 100 Mrad. We show that the irradiation time needed to reach very high total dose can be reduced by using Pelletron accelerator facilities instead of conventional irradiation facilities.

  13. Improving radiation hardness in space-based Charge-Coupled Devices through the narrowing of the charge transfer channel

    Science.gov (United States)

    Hall, D. J.; Skottfelt, J.; Soman, M. R.; Bush, N.; Holland, A.

    2017-12-01

    Charge-Coupled Devices (CCDs) have been the detector of choice for imaging and spectroscopy in space missions for several decades, such as those being used for the Euclid VIS instrument and baselined for the SMILE SXI. Despite the many positive properties of CCDs, such as the high quantum efficiency and low noise, when used in a space environment the detectors suffer damage from the often-harsh radiation environment. High energy particles can create defects in the silicon lattice which act to trap the signal electrons being transferred through the device, reducing the signal measured and effectively increasing the noise. We can reduce the impact of radiation on the devices through four key methods: increased radiation shielding, device design considerations, optimisation of operating conditions, and image correction. Here, we concentrate on device design operations, investigating the impact of narrowing the charge-transfer channel in the device with the aim of minimising the impact of traps during readout. Previous studies for the Euclid VIS instrument considered two devices, the e2v CCD204 and CCD273, the serial register of the former having a 50 μm channel and the latter having a 20 μm channel. The reduction in channel width was previously modelled to give an approximate 1.6× reduction in charge storage volume, verified experimentally to have a reduction in charge transfer inefficiency of 1.7×. The methods used to simulate the reduction approximated the charge cloud to a sharp-edged volume within which the probability of capture by traps was 100%. For high signals and slow readout speeds, this is a reasonable approximation. However, for low signals and higher readout speeds, the approximation falls short. Here we discuss a new method of simulating and calculating charge storage variations with device design changes, considering the absolute probability of capture across the pixel, bringing validity to all signal sizes and readout speeds. Using this method, we

  14. The comprehensive registration and information system of radiation protection regulatory authority in the Czech Republic

    International Nuclear Information System (INIS)

    Petrova, K.

    2004-01-01

    The central registration system in radiation protection is created in the Czech Republic since the 1997 year. Since that time the central registries of licensees, ionizing radiation sources (IRS) and occupational of workers doses has been developed by the State Office for Nuclear Safety (SUJB) in accordance with the demands of the new Czech legislation. The core of this complex information system is created by the Central Register of Licensees (CRL). The Central Register of Occupational Exposure (CROE) and the Central Register of Ionising Radiation Sources (CRIRS) are connected to CRL and provides with the list of workers their doses and relevant sources for each licensee. The Central Register of Approvals (CRA) issued by SUJB has been also created in 2002 and it was implemented into the system. The further register of inspections is recently under development. The whole system is operated in Oracle database. CRL registers all relevant information on the level of licensee, their workplaces and also on the level of smaller working units (labs, buildings, ..) where is necessary for more precise information about the placement of sources. The data are updated continuously. CROE collects personal and dosimetric data for all monitored workers in whole country. This register also includes the information on the personal radiation passports distributed by SUJB to external workers. CRIRS registers sealed IRS, devices with sealed IRS, generators and specification of workplaces with unsealed IRS. Users are obliged to report information on new source specified by Decree on radiation protection within one months. They shall report also all changes of registered data including the transfer of source to another user or to final disposal. CRA enables to issue automatically the licence in unified form and provides users with the different control tools of issued licences. Described comprehensive information system serves as very important and useful tool for effective regulation

  15. A study of radiation vulnerability of ferroelectric material and devices

    Energy Technology Data Exchange (ETDEWEB)

    Coic, Y M; Musseau, O; Leray, J L [CEA Centre d` Etudes de Bruyeres-le-Chatel, 91 (France)

    1994-12-31

    The radiation effects on ferroelectric material and devices are presented, based on commercially available samples. After recalling the background, effects in ferroelectric PZT capacitors are presented, concerning dose, neutrons and fatigue associated with dose effects. Physical implications and interpretations are sketched. In a second stage, effects are studied at the complete non-volatile RAM device level. Vulnerability in dose, dose rate and neutron fluence of commercial 4 kbit ferroelectric RAM is addressed. 64 kbit results are mentioned in dose rate. These results are compared to previously published data from other manufacturers or laboratories and supplement them. In the appendix, equivalence between rad (Si) and rad (PZT) is discussed in the case of low energy ``10 keV Aracor`` s-rays and {sup 60}Co gamma rays. (author). 24 refs., 11 figs., 7 tabs.

  16. A study of radiation vulnerability of ferroelectric material and devices

    International Nuclear Information System (INIS)

    Coic, Y.M.; Musseau, O.; Leray, J.L.

    1994-01-01

    The radiation effects on ferroelectric material and devices are presented, based on commercially available samples. After recalling the background, effects in ferroelectric PZT capacitors are presented, concerning dose, neutrons and fatigue associated with dose effects. Physical implications and interpretations are sketched. In a second stage, effects are studied at the complete non-volatile RAM device level. Vulnerability in dose, dose rate and neutron fluence of commercial 4 kbit ferroelectric RAM is addressed. 64 kbit results are mentioned in dose rate. These results are compared to previously published data from other manufacturers or laboratories and supplement them. In the appendix, equivalence between rad (Si) and rad (PZT) is discussed in the case of low energy ''10 keV Aracor'' s-rays and 60 Co gamma rays. (author). 24 refs., 11 figs., 7 tabs

  17. New challenge for the radiation protection: devices for the radioactivity dispersion

    International Nuclear Information System (INIS)

    Mora, J. C.; Robles, B.; Cancio, C.

    2006-01-01

    In recent years the terrorist attacks produced in several countries have changed the mind of the security experts. This has also included the Radiation Protection aspects. Newly considered features have required the update of emergency response and preparedness, ad well as a greater emphasis on security. Within the Radiation Protection field has been introduced the radiological and nuclear terrorism definition. almost every organism and research centre involved in Radiation Protection is nowadays working on. The possible terrorist attack scenarios have already been defined and the use of an explosive to disperse radioactive material, known as a Radiation Dispersion Devices (RDD), has been specified as the most probable one. Studies to mitigate against the chance of attack and to mitigate the consequences of any attack with a RDD are complex, due to the innovation that introduce. This leads to a need to take some immediate preventative actions and to carry out additional R and D efforts. This document presents some considerations on the possible RDD design and behaviour in order to prevent and prepare against a possible attack. (Author) 17 refs

  18. A conceptual design of the set-up for solid state spectroscopy with free electron laser and insertion device radiation

    CERN Document Server

    Makhov, V N

    2001-01-01

    The set-up for complex solid state spectroscopy with the use of enhanced properties of radiation from insertion devices and free electron lasers is proposed. Very high flux and pulsed properties of radiation from insertion devices and free electron lasers offer the possibility for the use of such powerful techniques as electron paramagnetic resonance (EPR) and optically detected magnetic resonance (ODMR) for the studies of excited states of electronic excitations or defects in solids. The power density of radiation can become high enough for one more method of exited-state spectroscopy: transient optical absorption spectroscopy. The set-up is supposed to combine the EPR/ODMR spectrometer, i.e. cryostat supplied with superconducting magnet and microwave system, and the optical channels for excitation (by radiation from insertion devices or free electron laser) and detection of luminescence (i.e. primary and secondary monochromators). The set-up can be used both for 'conventional' spectroscopy of solids (reflec...

  19. Use of ionising radiation in the teaching of physics and chemistry

    International Nuclear Information System (INIS)

    2000-01-01

    The guide lays down the safety requirements for the use of radiation in school education, as well as the principles regulating the use of radiation sources without the safety licence referred to in section 16 of the Finnish Radiation Act (592/1991). The guide covers the use of radiation sources emitting ionising radiation in elementary schools and high schools, as well as the use of radiation in the teaching of physics and chemistry in vocational training institutions and corresponding educational institutions

  20. When to Renew Software Licences at HPC Centres? A Mathematical Analysis

    Science.gov (United States)

    Baolai, Ge; MacIsaac, Allan B.

    2010-11-01

    In this paper we study a common problem faced by many high performance computing (HPC) centres: When and how to renew commercial software licences. Software vendors often sell perpetual licences along with forward update and support contracts at an additional, annual cost. Every year or so, software support personnel and the budget units of HPC centres are required to make the decision of whether or not to renew such support, and usually such decisions are made intuitively. The total cost for a continuing support contract can, however, be costly. One might therefore want a rational answer to the question of whether the option for a renewal should be exercised and when. In an attempt to study this problem within a market framework, we present the mathematical problem derived for the day to day operation of a hypothetical HPC centre that charges for the use of software packages. In the mathematical model, we assume that the uncertainty comes from the demand, number of users using the packages, as well as the price. Further we assume the availability of up to date software versions may also affect the demand. We develop a renewal strategy that aims to maximize the expected profit from the use the software under consideration. The derived problem involves a decision tree, which constitutes a numerical procedure that can be processed in parallel.

  1. When to Renew Software Licences at HPC Centres? A Mathematical Analysis

    International Nuclear Information System (INIS)

    Baolai, Ge; MacIsaac, Allan B

    2010-01-01

    In this paper we study a common problem faced by many high performance computing (HPC) centres: When and how to renew commercial software licences. Software vendors often sell perpetual licences along with forward update and support contracts at an additional, annual cost. Every year or so, software support personnel and the budget units of HPC centres are required to make the decision of whether or not to renew such support, and usually such decisions are made intuitively. The total cost for a continuing support contract can, however, be costly. One might therefore want a rational answer to the question of whether the option for a renewal should be exercised and when. In an attempt to study this problem within a market framework, we present the mathematical problem derived for the day to day operation of a hypothetical HPC centre that charges for the use of software packages. In the mathematical model, we assume that the uncertainty comes from the demand, number of users using the packages, as well as the price. Further we assume the availability of up to date software versions may also affect the demand. We develop a renewal strategy that aims to maximize the expected profit from the use the software under consideration. The derived problem involves a decision tree, which constitutes a numerical procedure that can be processed in parallel.

  2. Safety and regulatory aspects in the utilization of radiation and radioactive material

    International Nuclear Information System (INIS)

    Abdul Majid Hasan

    1987-01-01

    The main objective of the Atomic Energy Licensing Act, 1984 is to regulate and control all activities dealing with atomic energy. For this purpose the Atomic Energy Licensing Board, (AELB) was established and responsibilities for authorizing, enforcing and establishing guidelines of activities to ensure safety for radiation workers, members of public and environment. To achieve these functions AELB will assess the proposed activities, if safe licence will be issued within its conditions. To ensure the licensee comply with the conditions of licence, a team of inspectorate will inspect its operation. AELB also provides guidelines and procedures of radiation protection to the licensee and anyone who intends to involve in utilization of atomic energy. (author)

  3. WE-D-BRE-01: A Sr-90 Irradiation Device for the Study of Cutaneous Radiation Injury

    Energy Technology Data Exchange (ETDEWEB)

    Dorand, JE; Bourland, JD [Department of Radiation Oncology and Department of Physics, Wake Forest University, Winston-Salem, NC (United States); Burnett, LR [KeraNetics, LLC, Winston-Salem, NC (United States); Tytell, M [Department of Neurobiology and Anatomy, Wake Forest School of Medicine, Winston-Salem, NC (United States)

    2014-06-15

    Purpose: To determine dosimetric character for a custom-built Sr-90 beta irradiator designed for the study of Cutaneous Radiation Injury (CRI) in a porcine animal model. In the event of a radiological accident or terrorist event, Sr-90, a fission by-product, will likely be produced. CRI is a main concern due to the low energy and superficial penetration in tissue of beta particles from Sr-90. Seven 100 mCi plaque Sr-90 radiation sources within a custom-built irradiation device create a 40 mm diameter region of radiation-induced skin injury as part of a larger project to study the efficacy of a topical keratin-based product in CRI healing. Methods: A custom-built mobile irradiation device was designed and implemented for in vivo irradiations. Gafchromic™ EBT3 radiochromic film and a PTW Markus chamber type 23343 were utilized for dosimetric characterization of the beta fluence at the surface produced by this device. Films were used to assess 2-dimensional dose distribution and percent depth dose characteristics of the radiation field. Ion chamber measurements provided dose rate data within the field. Results: The radiation field produced by the irradiation device is homogeneous with high uniformity (∼5%) and symmetry (∼3%) with a steep dose fall-off with depth from the surface. Dose rates were determined to be 3.8 Gy/min and 3.3 Gy/min for film and ion chamber measurements, respectively. A dose rate of 3.4 Gy/min was used to calculate irradiation times for in vivo irradiations. Conclusion: The custom-built irradiation device enables the use of seven Sr-90 beta sources in an array to deliver a 40 mm diameter area of homogeneous skin dose with a dose rate that is useful for research purposes and clinically relevant for the induction of CRI. Doses of 36 and 42 Gy successfully produce Grade III CRI and are used in the study of the efficacy of KeraStat™. This project has been funded in whole or in part with Federal funds from the Biomedical Advanced Research and

  4. Report by the work-group on 'safety of medical devices emitting ionizing radiations'. Articulation of radiation protection requirements of the 97/43/Euratom directive and IAEA recommendations with the essential requirements of the 93/42/CEE directive related to medical devices used in external radiotherapy

    International Nuclear Information System (INIS)

    2010-01-01

    As some dysfunctions and events had been reported in 2007 and 2008 in field of radiotherapy, this report aims at clarifying the articulation between the different European regulations concerning medical devices emitting ionizing radiations and radiation protection. The authors report a survey with device manufacturers, and analyze the content of the different regulations and recommendations. Then, the authors recommend and propose a set of actions related to the IAEA requirements and recommendations, to CE marking requirements, and to new radiation protection and safety requirements present in the Euratom directive

  5. Radiation-induced interface state generation in MOS devices with reoxidised nitrided SiO2 gate dielectrics

    International Nuclear Information System (INIS)

    Lo, G.Q.; Shih, D.K.; Ting, W.; Kwong, D.L.

    1989-01-01

    In this letter, the radiation-induced interface state generation ΔD it in MOS devices with reoxidised nitrided gate oxides has been studied. The reoxidised nitrided oxides were fabricated by rapid thermal reoxidation (RTO) of rapidly thermal nitrided (RTN) SiO 2 . The devices were irradiated by exposure to X-rays at doses of 0.5-5.0 Mrad (Si). It is found that the RTO process improves the radiation hardness of RTN oxides in terms of interface state generation. The enhanced interface ''hardness'' of reoxidised nitrided oxides is attributed to the strainless interfacial oxide regrowth or reduction of hydrogen concentration during RTO of RTN oxides. (author)

  6. Filter and window assemblies for high power insertion device synchrotron radiation sources

    International Nuclear Information System (INIS)

    Khounsary, A.M.; Viccaro, P.J.; Kuzay, T.M.

    1992-01-01

    The powerful beams of x-ray radiation generated by insertion devices at high power synchrotron facilities deposit substantial amounts of localized heat in the front end and optical components that they intercept. X-ray beams from undulator sources, in particular, are confined to very narrow solid angles and therefore impose very high absorbed heat fluxes. This paper is devoted to a detailed study of the design of windows for the Advanced Photon Source undulators and wigglers, emphasizing alternative design concepts, material considerations, and cooling techniques necessary for handling the high heat load of the insertion devices. Various designs are thermally and structurally analyzed by numerically simulating full-power operating conditions. This analysis also has relevance to the design and development of other beam line components which are subjected to the high heat loads of insertion devices

  7. Total-dose radiation effects data for semiconductor devices. 1985 supplement. Volume 2, part A

    International Nuclear Information System (INIS)

    Martin, K.E.; Gauthier, M.K.; Coss, J.R.; Dantas, A.R.V.; Price, W.E.

    1986-05-01

    Steady-state, total-dose radiation test data, are provided in graphic format for use by electronic designers and other personnel using semiconductor devices in a radiation environment. The data were generated by JPL for various NASA space programs. This volume provides data on integrated circuits. The data are presented in graphic, tabular, and/or narrative format, depending on the complexity of the integrated circuit. Most tests were done using the JPL or Boeing electron accelerator (Dynamitron) which provides a steady-state 2.5 MeV electron beam. However, some radiation exposures were made with a cobalt-60 gamma ray source, the results of which should be regarded as only an approximate measure of the radiation damage that would be incurred by an equivalent electron dose

  8. Theoretic simulation for CMOS device on total dose radiation response

    International Nuclear Information System (INIS)

    He Baoping; Zhou Heqin; Guo Hongxia; He Chaohui; Zhou Hui; Luo Yinhong; Zhang Fengqi

    2006-01-01

    Total dose effect is simulated for C4007B, CC4007RH and CC4011 devices at different absorbed dose rate by using linear system theory. When irradiation response and dose are linear, total dose radiation and post-irradiation annealing at room temperature are determined for one random by choosing absorbed dose rate, and total dose effect at other absorbed dose rate can be predicted by using linear system theory. The simulating results agree with the experimental results at different absorbed dose rate. (authors)

  9. Post-licence driver education for the prevention of road traffic crashes: a systematic review of randomised controlled trials.

    Science.gov (United States)

    Ker, Katharine; Roberts, Ian; Collier, Timothy; Beyer, Fiona; Bunn, Frances; Frost, Chris

    2005-03-01

    The effectiveness of post-licence driver education for preventing road traffic crashes was quantified using a systematic review and meta-analyses of randomised controlled trials. Searches of appropriate electronic databases, the Internet and reference lists of relevant papers were conducted. The searches were not restricted by language or publication status. Data were pooled from 21 randomised controlled trials, including over 300,000 full licence-holding drivers of all ages. Nineteen trials reported subsequent traffic offences, with a pooled relative risk of 0.96 (95% confidence interval 0.94, 0.98). Fifteen trials reported traffic crashes with a pooled relative risk of 0.98 (0.96, 1.01). Four trials reported injury crashes with a pooled relative risk of 1.12 (0.88, 1.41). The results provide no evidence that post-licence driver education is effective in preventing road injuries or crashes. Although the results are compatible with a small reduction in the occurrence of traffic crashes, this may be due to selection biases or bias in the included trials.

  10. No 592 - Radiation Act

    International Nuclear Information System (INIS)

    1991-01-01

    This Act will enter into force on 1 January 1992. The scope of the Act is extensive as, in addition to ionizing radiation, it will also apply to activities involving exposure to natural radiation and non-ionizing radiation. Its purpose is to prevent and restrict harmful effects to health resulting from radiation. The basic principles of the Act are that the practice involving radiation should be justified; radiation protection should be optimized; and radiation doses should be as low as reasonably achievable. Licensed organisations using radiation will be responsible for the safety of the activity involving exposure to radiation and for having available the appropriate expertise to this effect. The required so-called safety licence provides the regulatory control to ensure that radiation is used sensibly, that the equipment and shields are technically acceptable and the operating personnel is competent, and that the radioactive waste is dealt with appropriately. The Radiation Act will also apply to nuclear activities within the scope of the 1987 Nuclear Energy Act [fr

  11. Regulatory requirements of radiation protection for veterinary nuclear medicine

    International Nuclear Information System (INIS)

    Ernst-Elz, Andreas

    2010-01-01

    The application of radionuclides for diagnostic and therapy in veterinary medicine requires permission by terms of German radiation protection ordinance. Conditions for granting this licence are described. Preconditions are the requisite qualification of the veterinarian and the structural conditions of radiation protection. It is necessary to consider the possible exposure of the public by radioactive waste and by animals after their discharge from treatment. (orig.)

  12. Ordinance of 18 January 1984 on definitions and licences in the atomic energy field

    International Nuclear Information System (INIS)

    1984-01-01

    This Ordinance (RS 732.11) repeals the 1978 Ordinance on definitions and licences in the atomic energy field with the exception of Annexes 2 and 3 and concerns in particular, the licensing procedure for atomic installations. It also regulates the export, import and transit of nuclear materials and equipment. (NEA) [fr

  13. Radiation protection and nuclear safety - achievements and the way ahead for ARPANSA

    International Nuclear Information System (INIS)

    Loy, J.

    2001-01-01

    Australian Radiation Protection and Nuclear Safety Agency (ARPANSA), a fully independent legislative and regulatory agency, was announced in 1997, but formally came into existence in 1999. The first stage of its development as a regulator was guiding Commonwealth users of radiation sources and nuclear facilities through making licence applications. Assessing licences was complex, including because of the need to work with the public submission process for nuclear facilities. This presentation will briefly outline the legislative framework and the regulatory arrangements that were instrumental in the creation of ARPANSA and discusses at length the implementation phase and achievements to date. The Commonwealth jurisdiction differs from the States - ARPANSA's challenge is now to learn how to move to the surveillance and audit stage of licensing

  14. Radiation Practices. Annual Report 2003

    International Nuclear Information System (INIS)

    Rantanen, E.

    2004-01-01

    A total of 1811 safety licences for the use of radiation were current at the end of 2003. There were 1962 responsible parties engaged in licence-exempt dental X-ray practices, made notifiable to STUK. Regulatory control of the use of radiation was carried out through regular inspections performed at places of use, postal control, guidance, maintenance of a Dose Register and research intended to support the regulatory control. A total of 10 900 workers engaged in radiation work were subject to individual monitoring in 2003. 135 000 dose entries were made in the register maintained by STUK. In no case did the individual dose of any worker exceed the dose limits stipulated in the Radiation Decree. Regulatory control of natural radiation concentrated on radon at workplaces and exposure of aircrews to cosmic radiation. At the end of 2003, 90 workplaces including a total of 141 work areas were subject to ongoing radon monitoring. A total of 2485 pilots and cabin crew members were monitored for exposure to cosmic radiation. Metrological activities continued with calibration and development work as in previous years. The DOS Laboratory of STO joined the international MRA agreement on the 'self declaration principle'. Regulatory control of the use of non-ionizing radiation focused particularly on mobile phones and sun-beds. Mobile phone market control began by measuring the radiation produced by a range of 12 mobile phones of varying type. Spot check inspections were conducted at tanning facilities and a report was completed on radiation safety improvements at such establishments. A method of measurement based on commercial CCD spectroradiometers was developed for spectral measurements of UV phototherapy appliances and sunbeds. The said method is also suitable for measurements at places of use. A new type of magnetometer, which measures peak values over a wide frequency band weighted according to exposure limits, was developed for measuring low frequency magnetic fields. In

  15. Emergency response activities and the collection of damaged radiation devices in the war areas of Croatia

    International Nuclear Information System (INIS)

    Subasic, D.; Schaller, A.

    1998-01-01

    Several kinds of devices containing sources of ionizing radiation had been in use in the areas of Croatia which were affected by the recent war, principally in industrial and medical applications. The greater share of these devices was constituted by 151 radioactive lightning conductors with a maximum individual activity of 19.5 GBq and some 8300 smoke detectors. In the destruction caused by the war, some of these devices were damaged, destroyed or lost. The actions undertaken to retrieve them and their sources are described, as well as the experience gained and lessons learned. The importance of a well organized national regulatory system is underscored as a precondition for the efficient identification and safe recovery of radiation sources lying amidst the ruins in the area affected by the war. The experience gained in these actions may be applicable to similar situations caused by natural disasters such as earthquakes, floods, hurricanes, etc. and of particular interest to regulatory authorities for the drawing up of emergency preparedness plans. (author)

  16. Manifestation of plasmonic response in the detection of sub-terahertz radiation by graphene-based devices

    Science.gov (United States)

    Gayduchenko, I. A.; Fedorov, G. E.; Moskotin, M. V.; Yagodkin, D. I.; Seliverstov, S. V.; Goltsman, G. N.; Kuntsevich, A. Yu; Rybin, M. G.; Obraztsova, E. D.; Leiman, V. G.; Shur, M. S.; Otsuji, T.; Ryzhii, V. I.

    2018-06-01

    We report on the sub-terahertz (THz) (129–450 GHz) photoresponse of devices based on single layer graphene and graphene nanoribbons with asymmetric source and drain (vanadium and gold) contacts. Vanadium forms a barrier at the graphene interface, while gold forms an Ohmic contact. We find that at low temperatures (77 K) the detector responsivity rises with the increasing frequency of the incident sub-THz radiation. We interpret this result as a manifestation of a plasmonic effect in the devices with the relatively long plasmonic wavelengths. Graphene nanoribbon devices display a similar pattern, albeit with a lower responsivity.

  17. Adverse Events Involving Radiation Oncology Medical Devices: Comprehensive Analysis of US Food and Drug Administration Data, 1991 to 2015

    International Nuclear Information System (INIS)

    Connor, Michael J.; Marshall, Deborah C.; Moiseenko, Vitali; Moore, Kevin; Cervino, Laura; Atwood, Todd; Sanghvi, Parag; Mundt, Arno J.; Pawlicki, Todd; Recht, Abram; Hattangadi-Gluth, Jona A.

    2017-01-01

    Purpose: Radiation oncology relies on rapidly evolving technology and highly complex processes. The US Food and Drug Administration collects reports of adverse events related to medical devices. We sought to characterize all events involving radiation oncology devices (RODs) from the US Food and Drug Administration's postmarket surveillance Manufacturer and User Facility Device Experience (MAUDE) database, comparing these with non–radiation oncology devices. Methods and Materials: MAUDE data on RODs from 1991 to 2015 were sorted into 4 product categories (external beam, brachytherapy, planning systems, and simulation systems) and 5 device problem categories (software, mechanical, electrical, user error, and dose delivery impact). Outcomes included whether the device was evaluated by the manufacturer, adverse event type, remedial action, problem code, device age, and time since 510(k) approval. Descriptive statistics were performed with linear regression of time-series data. Results for RODs were compared with those for other devices by the Pearson χ"2 test for categorical data and 2-sample Kolmogorov-Smirnov test for distributions. Results: There were 4234 ROD and 4,985,698 other device adverse event reports. Adverse event reports increased over time, and events involving RODs peaked in 2011. Most ROD reports involved external beam therapy (50.8%), followed by brachytherapy (24.9%) and treatment planning systems (21.6%). The top problem types were software (30.4%), mechanical (20.9%), and user error (20.4%). RODs differed significantly from other devices in each outcome (P<.001). RODs were more likely to be evaluated by the manufacturer after an event (46.9% vs 33.0%) but less likely to be recalled (10.5% vs 37.9%) (P<.001). Device age and time since 510(k) approval were shorter among RODs (P<.001). Conclusions: Compared with other devices, RODs may experience adverse events sooner after manufacture and market approval. Close postmarket surveillance, improved

  18. Adverse Events Involving Radiation Oncology Medical Devices: Comprehensive Analysis of US Food and Drug Administration Data, 1991 to 2015

    Energy Technology Data Exchange (ETDEWEB)

    Connor, Michael J. [Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California (United States); Department of Radiation Oncology, University of California Irvine School of Medicine, Irvine, California (United States); Marshall, Deborah C.; Moiseenko, Vitali; Moore, Kevin; Cervino, Laura; Atwood, Todd; Sanghvi, Parag; Mundt, Arno J.; Pawlicki, Todd [Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California (United States); Recht, Abram [Department of Radiation Oncology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts (United States); Hattangadi-Gluth, Jona A., E-mail: jhattangadi@ucsd.edu [Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California (United States)

    2017-01-01

    Purpose: Radiation oncology relies on rapidly evolving technology and highly complex processes. The US Food and Drug Administration collects reports of adverse events related to medical devices. We sought to characterize all events involving radiation oncology devices (RODs) from the US Food and Drug Administration's postmarket surveillance Manufacturer and User Facility Device Experience (MAUDE) database, comparing these with non–radiation oncology devices. Methods and Materials: MAUDE data on RODs from 1991 to 2015 were sorted into 4 product categories (external beam, brachytherapy, planning systems, and simulation systems) and 5 device problem categories (software, mechanical, electrical, user error, and dose delivery impact). Outcomes included whether the device was evaluated by the manufacturer, adverse event type, remedial action, problem code, device age, and time since 510(k) approval. Descriptive statistics were performed with linear regression of time-series data. Results for RODs were compared with those for other devices by the Pearson χ{sup 2} test for categorical data and 2-sample Kolmogorov-Smirnov test for distributions. Results: There were 4234 ROD and 4,985,698 other device adverse event reports. Adverse event reports increased over time, and events involving RODs peaked in 2011. Most ROD reports involved external beam therapy (50.8%), followed by brachytherapy (24.9%) and treatment planning systems (21.6%). The top problem types were software (30.4%), mechanical (20.9%), and user error (20.4%). RODs differed significantly from other devices in each outcome (P<.001). RODs were more likely to be evaluated by the manufacturer after an event (46.9% vs 33.0%) but less likely to be recalled (10.5% vs 37.9%) (P<.001). Device age and time since 510(k) approval were shorter among RODs (P<.001). Conclusions: Compared with other devices, RODs may experience adverse events sooner after manufacture and market approval. Close postmarket surveillance

  19. The new look for radiation regulation

    International Nuclear Information System (INIS)

    Loy, J.

    1999-01-01

    The Australian Radiation Protection and Nuclear Safety Act (1998) provides the CEO of the Australian Radiation Protection and Nuclear Safety Agency with responsibilities related to researching and advising on radiation protection and nuclear safety, and powers to regulate the Commonwealth's use of radiation and nuclear facilities. This regulation is new to Commonwealth departments and agencies. To support the CEO in meeting these responsibilities and exercising the regulatory powers, the Act also establishes a new advisory council and two advisory committees. Other novel aspects of the Act include a public consultation process for applications for licence related to nuclear facilities, and a regime of quarterly reporting by the CEO to Parliament, in addition to the usual requirements for annual reports

  20. Radioactive waste safety appraisal. An international peer review of the licence application for the Australian near surface radioactive waste disposal facility. Report of the IAEA International Review Team

    International Nuclear Information System (INIS)

    2004-05-01

    Radioactive waste has been generated in Australia for a number of decades from the production and use of radioactive materials in medicine and industry, from the processing of various minerals containing natural radionuclides and from various research activities. It has been decided in the overall interest of safety and security to develop a radioactive waste disposal facility to accommodate the low level and short lived intermediate level waste, which make up the bulk of the waste, other than mining and minerals processing residues. A site selection process has been undertaken and environmental impact statement report prepared and approved. A licence application has been submitted to the national nuclear regulatory authority, the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) for siting, construction and operation of the facility. In order to assist the CEO of ARPANSA with his deliberations in this regard a request was made to the IAEA, in terms of its statutory mandate to establish international safety standards for radioactive waste safety and to provide for their application, to undertake an international peer review of the licence application and to advise the CEO accordingly. The outcome and recommendations of this peer review are presented in the report

  1. Linking the Regulatory and Reimbursement Processes for Medical Devices : The Need for Integrated Assessments

    NARCIS (Netherlands)

    Ciani, Oriana; Wilcher, Britni; van Giessen, Anoukh; Taylor, Rod S.

    2017-01-01

    Much criticism has been directed at the licencing requirements for medical devices (MDs) as they often result in a lack of robust evidence to inform health technology assessment (HTA) decisions. To better understand the current international decisional framework on MD technologies, we undertook

  2. Intercomparison of radiation protection protection devices in a high-energy stray neutron field. Part III: Instrument response

    Czech Academy of Sciences Publication Activity Database

    Silari, M.; Agosteo, S.; Beck, P.; Bedogni, R.; Cale, E.; Caresana, M.; Domingo, C.; Donadille, L.; Dubourg, N.; Esposito, A.; Fehrenbacher, G.; Fernández, F.; Ferrarini, M.; Fiechtner, A.; Fuchs, A.; García, M. J.; Golnik, N.; Gutermuth, F.; Khurana, S.; Klages, T.; Latocha, M.; Mares, V.; Mayer, S.; Radon, T.; Reithmeier, H.; Rollet, S.; Roos, H.; Rühm, W.; Sandri, S.; Schardt, D.; Simmer, G.; Spurný, František; Trompier, F.; Villa-Grasa, C.; Weitzenegger, E.; Wiegel, B.; Wielunski, M.; Wissmann, F.; Zechner, A.; Zielczyński, M.

    2009-01-01

    Roč. 44, 7-8 (2009), s. 673-691 ISSN 1350-4487 R&D Projects: GA AV ČR IAA100480902 Institutional research plan: CEZ:AV0Z10480505 Keywords : radiation protection devices * radiation field * detectors * dosemeters Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 0.973, year: 2009

  3. Standard Practice for Minimizing Dosimetry Errors in Radiation Hardness Testing of Silicon Electronic Devices Using Co-60 Sources

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This practice covers recommended procedures for the use of dosimeters, such as thermoluminescent dosimeters (TLD's), to determine the absorbed dose in a region of interest within an electronic device irradiated using a Co-60 source. Co-60 sources are commonly used for the absorbed dose testing of silicon electronic devices. Note 1—This absorbed-dose testing is sometimes called “total dose testing” to distinguish it from “dose rate testing.” Note 2—The effects of ionizing radiation on some types of electronic devices may depend on both the absorbed dose and the absorbed dose rate; that is, the effects may be different if the device is irradiated to the same absorbed-dose level at different absorbed-dose rates. Absorbed-dose rate effects are not covered in this practice but should be considered in radiation hardness testing. 1.2 The principal potential error for the measurement of absorbed dose in electronic devices arises from non-equilibrium energy deposition effects in the vicinity o...

  4. Risks of carcinogenesis from electromagnetic radiation of mobile telephony devices.

    Science.gov (United States)

    Yakymenko, I; Sidorik, E

    2010-07-01

    Intensive implementation of mobile telephony technology in everyday human life during last two decades has given a possibility for epidemiological estimation of long-term effects of chronic exposure of human organism to low-intensive microwave (MW) radiation. Latest epidemiological data reveal a significant increase in risk of development of some types of tumors in chronic (over 10 years) users of mobile phone. It was detected a significant increase in incidence of brain tumors (glioma, acoustic neuroma, meningioma), parotid gland tumor, seminoma in long-term users of mobile phone, especially in cases of ipsilateral use (case-control odds ratios from 1.3 up to 6.1). Two epidemiological studies have indicated a significant increase of cancer incidence in people living close to the mobile telephony base station as compared with the population from distant area. These data raise a question of adequacy of modern safety limits of electromagnetic radiation (EMR) exposure for humans. For today the limits were based solely on the conception of thermal mechanism of biological effects of RF/MW radiation. Meantime the latest experimental data indicate the significant metabolic changes in living cell under the low-intensive (non-thermal) EMR exposure. Among reproducible biological effects of low-intensive MWs are reactive oxygen species overproduction, heat shock proteins expression, DNA damages, apoptosis. The lack of generally accepted mechanism of biological effects of low-intensive non-ionizing radiation doesn't permit to disregard the obvious epidemiological and experimental data of its biological activity. Practical steps must be done for reasonable limitation of excessive EMR exposure, along with the implementation of new safety limits of mobile telephony devices radiation, and new technological decisions, which would take out the source of radiation from human brain.

  5. Development of microfluidic devices for biomedical applications of synchrotron radiation infrared microspectroscopy

    OpenAIRE

    Birarda, Giovanni

    2011-01-01

    2009/2010 ABSTRACT DEVELOPMENT OF MICROFLUIDIC DEVICES FOR BIOMEDICAL APPLICATIONS OF SYNCHROTRON RADIATION INFRARED MICROSPECTROSCOPY by Birarda Giovanni The detection and measurement of biological processes in a complex living system is a discipline at the edge of Physics, Biology, and Engineering, with major scientific challenges, new technological applications and a great potential impact on dissection of phenomena occurring at tissue, cell, and sub cellular level. The ...

  6. Web software for the control and management of radiation protection devices in the Cadarache site

    International Nuclear Information System (INIS)

    Beltritti, F.

    2010-01-01

    This series of slides presents how to use a new software dedicated to the management of the periodical controls that have to be performed on the equipment involved in radiation protection. This software is ready to be dispatched on the CEA site of Cadarache. This software gives information on: the device to be controlled, the controls that have to be performed, the procedures to follow to make the test, the equipment necessary for the test particularly the need for radioactive sources, the maintenance of the device, the previous measurements and in the end the device's conformity. An evaluation of the conformity of all the devices present in a building or an area or of a particular type can be easily obtained. (A.C.)

  7. Reduction in radiation exposure to nursing personnel with the use of remote afterloading brachytherapy devices

    International Nuclear Information System (INIS)

    Grigsby, P.W.; Perez, C.A.; Eichling, J.; Purdy, J.; Slessinger, E.

    1991-01-01

    The radiation exposure to nursing personnel from patients with brachytherapy implants on a large brachytherapy service were reviewed. Exposure to nurses, as determined by TLD monitors, indicates a 7-fold reduction in exposure after the implementation of the use of remote afterloading devices. Quarterly TLD monitor data for six quarters prior to the use of remote afterloading devices demonstrate an average projected annual dose equivalent to the nurses of 152 and 154 mrem (1.5 mSv). After the implementation of the remote afterloading devices, the quarterly TLD monitor data indicate an average dose equivalent per nurse of 23 and 19 mrem (0.2 mSv). This is an 87% reduction in exposure to nurses with the use of these devices (p less than 0.01)

  8. Radiation Damage in Electronic Memory Devices

    Directory of Open Access Journals (Sweden)

    Irfan Fetahović

    2013-01-01

    Full Text Available This paper investigates the behavior of semiconductor memories exposed to radiation in order to establish their applicability in a radiation environment. The experimental procedure has been used to test radiation hardness of commercial semiconductor memories. Different types of memory chips have been exposed to indirect ionizing radiation by changing radiation dose intensity. The effect of direct ionizing radiation on semiconductor memory behavior has been analyzed by using Monte Carlo simulation method. Obtained results show that gamma radiation causes decrease in threshold voltage, being proportional to the absorbed dose of radiation. Monte Carlo simulations of radiation interaction with material proved to be significant and can be a good estimation tool in probing semiconductor memory behavior in radiation environment.

  9. Écrire un article de recherche dans un contexte de licence en FLE

    Directory of Open Access Journals (Sweden)

    Christelle Annick Ferraris

    2015-12-01

    Full Text Available Afin de commencer à conscientiser nos étudiants de licence à l’importance des écrits académiques, nous avons réalisé une recherche avec des apprenantes en dernier semestre de la Licence en Langues, option FLE, dans un cours de français de niveau C1 du DALF ; il s’agissait d’écrire le premier jet d’un article de recherche sur le thème de leur mémoire de fin d’études, publiable dans une revue spécialisée. Nous donnons d’abord le panorama général de l’écriture académique au sein de notre faculté puis les principes pédagogiques de la lecture/écriture de l’article de recherche en contexte universitaire et plus particulièrement en FLE. Nous rapportons ensuite le mode d’intervention suivi dans la classe et nous exposons les réactions des étudiantes sur l’expérience vécue et sur les difficultés rencontrées lors du processus d’écriture. Nous apportons finalement des réflexions qui pourront améliorer de futures interventions pédagogiques sur le sujet.

  10. Radiation Damage in Electronic Memory Devices

    OpenAIRE

    Fetahović, Irfan; Pejović, Milić; Vujisić, Miloš

    2013-01-01

    This paper investigates the behavior of semiconductor memories exposed to radiation in order to establish their applicability in a radiation environment. The experimental procedure has been used to test radiation hardness of commercial semiconductor memories. Different types of memory chips have been exposed to indirect ionizing radiation by changing radiation dose intensity. The effect of direct ionizing radiation on semiconductor memory behavior has been analyzed by using Monte Carlo simula...

  11. Safety lock for radiography exposure device

    International Nuclear Information System (INIS)

    Gaines, T.M.

    1982-01-01

    A safety lock for securing a radiation source in a radiography exposure device is disclosed. The safety lock prevents the inadvertent extension of the radiation source from the exposure device. The exposure devices are used extensively in industry for nondestructive testing of metal materials for defect. Unnecessary exposure of the radiographer or operator occurs not infrequently due to operator's error in believing that the radiation source is secured in the exposure device when, in fact, it is not. The present invention solves this problem of unnecessary exposure by releasingly trapping the radiation source in the shield of the radiography exposure device each time the source is retracted therein so that it is not inadvertently extended therefrom without the operator resetting the safety lock, thereby releasing the radiation source. Further, the safety lock includes an indicator which indicates when the source is trapped in the exposure device and also when it is untrapped. The safety lock is so designed that it does not prevent the return of the source to the trapped, shielded position in the exposure device. Further the safety lock includes a key means for locking the radiation source in the trapped position. The key means cannot be actuated until said radiation source is in said trapped position to further insure the safety lock cannot be inadvertently locked with the source untrapped and thus still extendable from the exposure device

  12. To sell or not to sell: cigarette sales in alcohol-licenced premises.

    Science.gov (United States)

    Burton, Suzan; Ludbrooke, Mark; Williams, Kelly; Walsberger, Scott C; Egger, Sam

    2017-11-27

    To obtain insight into tobacco retailing by alcohol-licenced premises, in order to understand the financial importance of tobacco sales for such retailers. Data were collected by a telephone survey of 1042 clubs, hotels and packaged liquor outlets in New South Wales, Australia. The response rate was 86.1%. Qualitative and quantitative data were obtained. Logistic and linear regression were used to determine factors associated with the probability of selling and stopping selling and the importance of cigarette sales. More than a third (36.4%) of premises contacted did not sell cigarettes. 147 (an estimated 18.1% of those who had ever sold) had stopped selling. There were significant differences in the probability of selling, in the reported importance of cigarette sales and in the probability of stopping selling, between different outlet types and other outlet characteristics (number of gaming machines, proximity of nearest alternative tobacco retailer and remoteness). Outlets where alcohol can be consumed were more likely to rate cigarette sales as 'not important' than 'important'. Despite claims by tobacco companies that tobacco sales are important for many Australian retailers, tobacco sales appear to be of limited importance for alcohol-licenced premises. This means that opposition to stopping tobacco sales where alcohol is consumed and/or sold may be less than expected. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  13. BNLs Synchrotron-radiation Research Hub for Characterizing Detection Materials and Devices for the NA-22 Community

    Energy Technology Data Exchange (ETDEWEB)

    Camarda, G. S. [Brookhaven National Lab. (BNL), Upton, NY (United States); Bolotnikov, A. E. [Brookhaven National Lab. (BNL), Upton, NY (United States); Cui, Y. [Brookhaven National Lab. (BNL), Upton, NY (United States); Hossain, A. [Brookhaven National Lab. (BNL), Upton, NY (United States); Roy, U. [Brookhaven National Lab. (BNL), Upton, NY (United States); Yang, G. [Brookhaven National Lab. (BNL), Upton, NY (United States); Vanier, P. [Brookhaven National Lab. (BNL), Upton, NY (United States); McDowell, Alastair [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Rosen, Chris [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Labrum, Joseph [Univ. of California, Berkeley, CA (United States)

    2017-03-01

    The goal of this project is to obtain and characterize scintillators, emerging- and commercial-compoundsemiconductor radiation- detection materials and devices provided by vendors and research organizations. The focus of our proposed research is to clarify the role of the deleterious defects and impurities responsible for the detectors' non-uniformity in scintillating crystals, commercial semiconductor radiation-detector materials, and in emerging R&D ones. Some benefits of this project addresses the need for fabricating high-performance scintillators and compound-semiconductor radiation-detectors with the proven potential for large-scale manufacturing. The findings help researchers to resolve the problems of non-uniformities in scintillating crystals, commercial semiconductor radiation-detector materials, and in emerging R&D ones.

  14. Tissue kerma vs distance relationships for initial nuclear radiation from the atomic devices detonated over Hiroshima and Nagasaki

    International Nuclear Information System (INIS)

    Kerr, G.D.; Pace, J.V. III; Scott, W.H. Jr.

    1983-06-01

    Initial nuclear radiation is comprised of prompt neutrons and prompt primary gammas from an exploding nuclear device, prompt secondary gammas produced by neutron interactions in the environment, and delayed neutrons and delayed fission-product gammas from the fireball formed after the nuclear device explodes. These various components must all be considered in establishing tissue kerma vs distance relationships which describe the decrease of initial nuclear radiation with distance in Hiroshima and in Nagasaki. The tissue kerma at ground evel from delayed fission-product gammas and delayed neutrons was investigated using the NUIDEA code developed by Science Applications, Inc. This code incorporates very detailed models which can take into account such features as the rise of the fireball, the rapid radioactive decay of fission products in it, and the perturbation of the atmosphere by the explosion. Tissue kerma vs distance relationships obtained by summing results of these current state-of-the-art calculations will be discussed. Our results clearly show that the prompt secondary gammas and delayed fission-product gammas are the dominant components of total tissue kerma from initial nuclear radiation in the cases of the atomic (or pure-fission) devices detonated over Hiroshima and Nagasaki

  15. New developments on the generation of arbitrary polarized radiation from insertion devices

    International Nuclear Information System (INIS)

    Elleaume, P.

    1991-01-01

    The complete description of the polarization of a beam of radiation is described in terms of the total energy and three polarization rates. The polarization characteristics from conventional undulators and wigglers is recalled. A presentation is made of some new insertion devices that were proposed and/or built to generate circular polarization and more generally to improve the control of polarization. They are the asymmetric and elliptical wigglers and the helical and crossed undulators

  16. Conducted and radiated noise in detection devices

    International Nuclear Information System (INIS)

    Moisa, D.

    2001-01-01

    Conducted and radiated noise is an external noise which affects the quality of the signals of the detectors. An external noise can be reduced, usually, by shielding. This was the situation with 'older fashion' devices which uses boxes and coaxial cables. As the devices becomes more complex, the shielding of the detectors is more and more difficult and the transmission lines evolves from coaxial cables to twisted pair cables which are no more shielded. In such situation, the conducted and radiated noise (C and R noise) becomes important. Due to complexity of a real detector, the main work is based on experiments with components and simulations of some specific problems, associated with CDC detector. The first experiment was done to understand how the C and R noise is propagated. The emission device was a set of coils (between 3 and 5 turns with diameter from 10 to 50 mm) feed by an 74S140 driver. A pulse of about 8 ns width was generated. A coil of reception of about the same physical characteristics was used to see the emitted pulse. When the two coils are separated by about 80 cm, the receiver generated no signal. But, if along the two coils, a conductive material is introduced (a wire for instance), the receiver senses a signal. This signal is not changed too much if the wire is or not connected to ground. The explanation is simple: the pulse in the emitting coil produces an EM pulse which spreads in space. If a conductive material is around, the EM energy is received by that conductor and it is propagated at tens of meters with small attenuation. When this energy reaches the end of the conductor, it is radiated in space. If some other conductors are around, the energy is received and propagated by that conductors. This experiment was done for about 20 kinds of conductors (different coax cables, twisted-pair ribbons, power cables, metallic bars) and with many coils (different diameters and numbers of turns). It was measured the pk-to-pk level, decay constant and

  17. NASDA technician test real-time radiation monitoring device

    Science.gov (United States)

    1997-01-01

    A technician from the National Space Development Agency of Japan (NASDA) tests the real-time radiation monitoring device on SPACEHAB at Kennedy Space Center in preparation for the STS-89 mission, slated to be the first Shuttle launch of 1998. STS-89 will be the eighth of nine scheduled Mir dockings and will include a double module of SPACEHAB, used mainly as a large pressurized cargo container for science, logistical equipment and supplies to be exchanged between the orbiter Endeavour and the Russian Space Station Mir. The nine-day flight of STS-89 also is scheduled to include the transfer of the seventh American to live and work aboard the Russian orbiting outpost. Liftoff of Endeavour and its seven-member crew is targeted for Jan. 15, 1998, at 1:03 a.m. EDT from Launch Pad 39A.

  18. Radiation emitter-detector package

    International Nuclear Information System (INIS)

    O'Brien, J.T.; Limm, A.C.; Nyul, P.; Tassia, V.S. Jr.

    1978-01-01

    Mounted on the metallic base of a radiation emitter-detector is a mounting block is a first projection, and a second projection. A radiation detector is on the first projection and a semiconductor electroluminescent device, i.e., a radiation emitter, is on the second projection such that the plane of the recombination region of the electroluminescent device is perpendicular to the radiation incident surface of the radiation detector. The electroluminescent device has a primary emission and a secondary emission in a direction different from the primary emission. A radiation emitter-detector package as described is ideally suited to those applications wherein the secondary radiation of the electroluminescent device is fed into a feedback circuit regulating the biasing current of the electroluminescent device

  19. Radiation protection in medicine 2002. Guide to radiation protection in the use of ionizing radiation (Strahlenschutzverordnung - StrlSchV). Revised edition with detailed explanations. 5. tot. new rev. and enl. ed.

    International Nuclear Information System (INIS)

    Kemmer, W.; Michalczak, H.

    2003-01-01

    Full text of the Guide to RAdiation Protection in Medicine; list of essential items to be considered when applying for a licence for the handling of sealed or unsealed radioactives substances; hints and instructions concerning application forms in procedures for thelicensing of installations for the generation of ionizing radiation; rules concerning inspection deadlines for testing the impermeability of the packing of sealed radioactive substances; list of the supervisory authorities of the German states responsible for supervision in the medical field; DIN norms and drafts relating to radiology

  20. An assessment of the effects of radiation on permanent magnet material in the ALS [Advanced Light Source] insertion devices

    International Nuclear Information System (INIS)

    Hassenzahl, W.V.; Jenkins, T.M.; Namito, Y.; Nelson, W.R.; Swanson, W.P.

    1989-08-01

    Electrons that are lost from the beam during normal operation of a synchrotron radiation source and during a beam dump at the end of a run produce both ionizing radiation and neutrons. This radiation has the potential for damaging sensitive materials, in particular those that need to be very close to the beam. The wigglers and undulators for the Advanced Light Source (ALS) at LBL will use magnetic materials such as the very high performance neodymium-iron-boron, which will be as close as 1 cm away from the electron beam during operation. This material, which is preferred because of its high remanence, is known to be more sensitive to radiation than some other magnetic materials. Simple energy loss estimates and the EGS4 code were used to estimate the radiation levels in the ALS insertion devices in the regions of the magnetic materials. The radiation levels were estimated for both aluminum and stainless steel vacuum chambers to determine if one would provide significantly better shielding. We conclude that Nd-Fe-B can be used in the ALS insertion devices and that there is little difference in the radiation levels for aluminum and stainless vacuum vessels. 8 refs., 7 figs., 1 tab

  1. [Morphological structure of rat epiphysis exposed to electromagnetic radiation from communication devices].

    Science.gov (United States)

    Yashchenko, S G; Rybalko, S Yu

    Pineal gland is one of the most important components of homeostasis - the supporting system of the body. It participates in the launch of stress responses, restriction of their development, prevention of adverse effects on the body. There was proved an impact of electromagnetic radiation on the epiphysis. However, morphological changes in the epiphysis under exposure to electromagnetic radiation of modern communication devices are studied not sufficiently. For the time present the population is daily exposed to electromagnetic radiation, including local irradiation on the brain. These date determined the task of this research - the study of the structure of rat pineal gland under the exposure to electromagnetic radiation from personal computers and mobile phones. These date determined the task of this research - the study of the structure of rat pineal gland under the exposure to electromagnetic radiation from personal computers and mobile phones. Performed transmission electron microscopy revealed signs of degeneration of dark and light pinealocytes. These signs were manifested in the development of a complex of general and specific morphological changes. There was revealed the appearance of signs of aging and depletion transmission electron microscopy both in light and dark pinealocytes. These signs were manifested in the accumulation of lipofuscin granules and electron-dense "brain sand", the disappearance of nucleoli, cytoplasm vacuolization and mitochondrial cristae enlightenment.

  2. Coating thickness measuring device

    International Nuclear Information System (INIS)

    Joffe, B.B.; Sawyer, B.E.; Spongr, J.J.

    1984-01-01

    A device especially adapted for measuring the thickness of coatings on small, complexly-shaped parts, such as, for example, electronic connectors, electronic contacts, or the like. The device includes a source of beta radiation and a radiation detector whereby backscatter of the radiation from the coated part can be detected and the thickness of the coating ascertained. The radiation source and detector are positioned in overlying relationship to the coated part and a microscope is provided to accurately position the device with respect to the part. Means are provided to control the rate of descent of the radiation source and radiation detector from its suspended position to its operating position and the resulting impact it makes with the coated part to thereby promote uniformity of readings from operator to operator, and also to avoid excessive impact with the part, thereby improving accuracy of measurement and eliminating damage to the parts

  3. High ionization radiation field remote visualization device - shielding requirements

    International Nuclear Information System (INIS)

    Fernandez, Antonio P. Rodrigues; Omi, Nelson M.; Silveira, Carlos Gaia da; Calvo, Wilson A. Pajero

    2011-01-01

    The high activity sources manipulation hot-cells use special and very thick leaded glass windows. This window provides a single sight of what is being manipulated inside the hot-cell. The use of surveillance cameras would replace the leaded glass window, provide other sights and show more details of the manipulated pieces, using the zoom capacity. Online distant manipulation may be implemented, too. The limitation is their low ionizing radiation resistance. This low resistance also limited the useful time of robots made to explore or even fix problematic nuclear reactor core, industrial gamma irradiators and high radioactive leaks. This work is a part of the development of a high gamma field remote visualization device using commercial surveillance cameras. These cameras are cheap enough to be discarded after the use for some hours of use in an emergency application, some days or some months in routine applications. A radiation shield can be used but it cannot block the camera sight which is the shield weakness. Estimates of the camera and its electronics resistance may be made knowing each component behavior. This knowledge is also used to determine the optical sensor type and the lens material, too. A better approach will be obtained with the commercial cameras working inside a high gamma field, like the one inside of the IPEN Multipurpose Irradiator. The goal of this work is to establish the radiation shielding needed to extend the camera's useful time to hours, days or months, depending on the application needs. (author)

  4. Electromagnetic radiation screening of semiconductor devices for long life applications

    Science.gov (United States)

    Hall, T. C.; Brammer, W. G.

    1972-01-01

    A review is presented of the mechanism of interaction of electromagnetic radiation in various spectral ranges, with various semiconductor device defects. Previous work conducted in this area was analyzed as to its pertinence to the current problem. The task was studied of implementing electromagnetic screening methods in the wavelength region determined to be most effective. Both scanning and flooding type stimulation techniques are discussed. While the scanning technique offers a considerably higher yield of useful information, a preliminary investigation utilizing the flooding approach is first recommended because of the ease of implementation, lower cost and ability to provide go-no-go information in semiconductor screening.

  5. Radiation-induced valvular heart disease.

    Science.gov (United States)

    Gujral, Dorothy M; Lloyd, Guy; Bhattacharyya, Sanjeev

    2016-02-15

    Radiation to the mediastinum is a key component of treatment with curative intent for a range of cancers including Hodgkin's lymphoma and breast cancer. Exposure to radiation is associated with a risk of radiation-induced heart valve damage characterised by valve fibrosis and calcification. There is a latent interval of 10-20 years between radiation exposure and development of clinically significant heart valve disease. Risk is related to radiation dose received, interval from exposure and use of concomitant chemotherapy. Long-term outlook and the risk of valve surgery are related to the effects of radiation on mediastinal structures including pulmonary fibrosis and pericardial constriction. Dose prediction models to predict the risk of heart valve disease in the future and newer radiation techniques to reduce the radiation dose to the heart are being developed. Surveillance strategies for this cohort of cancer survivors at risk of developing significant heart valve complications are required. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  6. The Measurement of Spectral Characteristics and Composition of Radiation in Atlas with MEDIPIX2-USB Devices

    Science.gov (United States)

    Campbell, M.; Doležal, Z.; Greiffenberg, D.; Heijne, E.; Holy, T.; Idárraga, J.; Jakůbek, J.; Král, V.; Králík, M.; Lebel, C.; Leroy, C.; Llopart, X.; Lord, G.; Maneuski, D.; Ouellette, O.; Sochor, V.; Pospíšil, S.; Suk, M.; Tlustos, L.; Vykydal, Z.; Wilhelm, I.

    2008-06-01

    A network of devices to perform real-time measurements of the spectral characteristics and composition of radiation in the ATLAS detector and cavern during its operation is being built. This system of detectors will be a stand alone system fully capable of delivering real-time images of fluxes and spectral composition of different particle species including slow and fast neutrons. The devices are based on MEDIPIX2 pixel silicon detectors that will be operated via active USB cables and USB-Ethernet extenders through an Ethernet network by a PC located in the USA15 ATLAS control room. The installation of 14 devices inside ATLAS (detector and cavern) is in progress.

  7. The Measurement of Spectral Characteristics and Composition of Radiation in ATLAS with MEDIPIX2-USB Devices

    CERN Document Server

    Campbell, M.; Greiffenberg, D.; Heijne, E.; Holy, T.; Idárraga, J.; Jakubek, J.; Král, V.; Králík, M.; Lebel, C.; Leroy, C.; Llopart, X.; Lord, G.; Maneuski, D.; Ouellette, O.; Sochor, V.; Prospísil, S.; Suk, M; Tlustos, L.; Vykydal, Z.; Wilhelm, I.

    2008-01-01

    A network of devices to perform real-time measurements of the spectral characteristics and composition of radiation in the ATLAS detector and cavern during its operation is being built. This system of detectors will be a stand alone system fully capable of delivering real-time images of fluxes and spectral composition of different particle species including slow and fast neutrons. The devices are based on MEDIPIX2 pixel silicon detectors that will be operated via active USB cables and USB-Ethernet extenders through an Ethernet network by a PC located in the USA15 ATLAS control room. The installation of 14 devices inside ATLAS (detector and cavern) is in progress.

  8. Radiation exposure control of nuclear power plant personnel in the Federal Republic of Germany

    International Nuclear Information System (INIS)

    Mehl, J.

    1980-01-01

    The analysis of exposure records of all persons engaged in radiation work at nuclear power plants of the Federal Republic of Germany has shown that annual collective doses increase rapidly with time. The annual gross electrical energy generated from nuclear power also increases rapidly with time, corresponding to about 11% of the total gross electrical energy produced in 1977/78. Therefore, it is obvious that there is an increase of both the risk and the benefit from nuclear power production. Whether in the course of time the situation develops more towards the risk or the benefit side is learned from the history of the annual ratio of the collective dose per gross electrical energy generated. This ratio shows a significant decrease since 1972. The decrease is due to the experience gained from operation of the first-generation plants, which led to several administrative measures aimed at an improved control of the collective doses of power plant personnel in the Federal Republic of Germany. The administrative measures include, among others, the introduction of the following requirements: (a) Everyone who applies for a nuclear power plant construction licence has to provide evidence that, in the design of the plant, full use is made of the experience gained from plants in operation with respect to reduction of collective doses of the power plant personnel. (b) Everyone who engages his employees on radiation work within operations for which an operation licence is required, but which is held by others, requires a special 'contractor licence'. (c) Every person engaged in radiation work on the basis of a contractor licence must carry a special exposure record book which is registered by the competent national authority. (author)

  9. Radiation Protection and Safety infrastructure in Albania

    International Nuclear Information System (INIS)

    Ylli, F.; Dollani, K.; Paci, R.

    2005-01-01

    On 1995 Albania Parliament approved the Radiation Protection Act, which established the Radiation Protection Commission as Regulatory Body and Radiation Protection Office as an executive office. The licensing of private and public companies is a duty of RPC and the inspections, enforcement, import - export control, safety and security of radioactive materials, are tasks of RPO. Regulations on licence and inspection, safe handling of radioactive sources, radioactive waste management and transport of radioactive materials have been approved. The Codes of practice in diagnostic radiology, radiotherapy and nuclear medicine have been prepared. Institute of Nuclear Physics carry out monitoring of personal dosimetry, response to the radiological emergencies, calibration of dosimetric equipment's, management of radioactive waste, etc. Based in the IAEA documents, a new Radiation Protection Act is under preparation

  10. Validité des licences de logiciel sous plastique en droit français et comparé

    NARCIS (Netherlands)

    Girot, C.A.

    1998-01-01

    The development of 'shrinkwrap licences' as an effective means to mass-market software has,oddly enough, generated no debate in France. Several foreign examples on the contrary tend to show that such discussion exists elsewhere in Europe and also in the United States and in Singapore. The article

  11. Semiconductor radiation detectors. Device physics

    International Nuclear Information System (INIS)

    Lutz, G.

    2007-01-01

    Starting from basic principles, the author, whose own contributions to these developments have been significant, describes the rapidly growing field of modern semiconductor detectors used for energy and position measurement radiation. This development was stimulated by requirements in elementary particle physics where it has led to important scientific discoveries. It has now spread to many other fields of science and technology. The book is written in a didactic way and includes an introduction to semiconductor physics. The working principles of semiconductor radiation detectors are explained in an intuitive way, followed by formal quantitative analysis. Broad coverage is also given to electronic signal readout and to the subject of radiation damage. The book is the first to comprehensively cover the semiconductor radiation detectors currently in use. It is useful as a teaching guide and as a reference work for research and applications. (orig.)

  12. Method and device for demounting in a radiation detector a photomultiplier tube

    International Nuclear Information System (INIS)

    Persyk, D.E.; Stoub, E.W.

    1986-01-01

    A device is described for demounting in a radiation detector a photomultiplier tube which is bonded with its scintillation crystal assembly by means of an elastic light transparent adhesive, comprising: (a) a music wire of about 0.01 to 0.03 inch diameter which forms a noose between its wire ends, the noose being provided for being placed aroung the bond; and (b) twisting means connected with both wire ends for twisting them such that the noose becomes smaller thereby sharing the bond

  13. Test results of the experimental laser device for potato tubers radiation treatment

    International Nuclear Information System (INIS)

    Anufrik, S.S.; Korzun, O.S.

    2007-01-01

    Results of 3 year investigation of the influence of the presowing low intensity laser radiation treatment of potato (Solanum tuberosum L.) tubers with the help of laser device with various spectral composition and exposition on plant growth, development and productivity and potato tubers quality and starch content in the conditions of the Republic of Belarus were presented. Presowing tubers treatment of potato cultivars Sante, Yavar and Arkhideya was realized by He-Ne, Ar-, Cu (in course of 3 and 5 minutes) and CO2 (in course of 5 seconds) lasers. Research results have shown that presowing treatment with CO2 laser promoted the higher (on 1,7-6,6%) potato germination capacity in comparison with the control variant without radiation treatment. Height of potato plants of Sante variety after radiation treatment fell behind the control ones. Haulm quantity per one plant and yield quality did not depend on radiation treatment Treatment with CO2 laser exercised the stimulatory action on productivity of Sante variety without changing the starch content in tubers. Tuber weight increased up to 0,4 kg (0,2 kg in the control variant). Similar effect for Arkhideya and Yavar varieties was obtained after Cu-laser treatment in course of 5 minutes. Radiation treatment with He-Ne laser caused the increased starch accumulation (on 0,4-0,6% in comparison with the control variant) in potato tubers of all studied varieties

  14. DeviceNet-based device-level control in SSRF

    CERN Document Server

    Leng Yong Bin; Lu Cheng Meng; Miao Hai Feng; Liu Song Qiang; Shen Guo Bao

    2002-01-01

    The control system of Shanghai Synchrotron Radiation Facility is an EPICS-based distributed system. One of the key techniques to construct the system is the device-level control. The author describes the design and implementation of the DeviceNet-based device controller. A prototype of the device controller was tested in the experiments of magnet power supply and the result showed a precision of 3 x 10 sup - sup 5

  15. A NOVEL, REMOVABLE, CERROBEND, BEAM-BLOCKING DEVICE FOR RADIATION THERAPY OF THE CANINE HEAD AND NECK: PILOT STUDY.

    Science.gov (United States)

    Kent, Michael S; Berlato, Davide; Vanhaezebrouck, Isabelle; Gordon, Ira K; Hansen, Katherine S; Theon, Alain P; Holt, Randall W; Trestrail, Earl A

    2017-01-01

    Radiation therapy of the head and neck can result in mucositis and other acute affects in the oral cavity. This prospective pilot study evaluated a novel, intraoral, beam-blocking device for use during imaging and therapeutic procedures. The beam-blocking device was made from a metal alloy inserted into a coated frozen dessert mold (Popsicle® Mold, Cost Plus World Market, Oakland, CA). The device was designed so that it could be inserted into an outer shell, which in turn allowed it to be placed or removed depending on the need due to beam configuration. A Farmer type ionization chamber and virtual water phantom were used to assess effects of field size on transmission. Six large breed cadaver dogs, donated by the owner after death, were recruited for the study. Delivered dose at the dorsal and ventral surfaces of the device, with and without the alloy block in place, were measured using radiochromic film. It was determined that transmission was field size dependent with larger field sizes leading to decreased attenuation of the beam, likely secondary to scatter. The mean and median transmission on the ventral surface without the beam-blocking device was 0.94 [range 0.94-0.96]. The mean and median transmission with the beam-blocking device was 0.52 [range 0.50-0.57]. The mean and median increase in dose due to backscatter on the dorsal surface of the beam-blocking device was 0.04 [range 0.02-0.04]. Findings indicated that this novel device can help attenuate radiation dose ventral to the block in dogs, with minimal backscatter. © 2016 American College of Veterinary Radiology.

  16. Continuous wave terahertz radiation from an InAs/GaAs quantum-dot photomixer device

    Science.gov (United States)

    Kruczek, T.; Leyman, R.; Carnegie, D.; Bazieva, N.; Erbert, G.; Schulz, S.; Reardon, C.; Reynolds, S.; Rafailov, E. U.

    2012-08-01

    Generation of continuous wave radiation at terahertz (THz) frequencies from a heterodyne source based on quantum-dot (QD) semiconductor materials is reported. The source comprises an active region characterised by multiple alternating photoconductive and QD carrier trapping layers and is pumped by two infrared optical signals with slightly offset wavelengths, allowing photoconductive device switching at the signals' difference frequency ˜1 THz.

  17. Evaluation of stability of polymeric insulation materials in radiation fields and development of radiation stable PVC and polypropylene for medical devices

    International Nuclear Information System (INIS)

    Gonzalez, M.E.; Docters, A.S.

    1999-01-01

    Radiation stability of polypropylene and polyvinylchloride medical products of local origin was evaluated, establishing their functionality by appropriate methods. A device for a mechanical test of syringes and another device for puncture testing of plastic films were constructed and tested. Shelf-life anticipation of irradiated products was examined by treating to high doses and in other cases by storing irradiated products at high temperatures. In both cases negative results would anticipate no functionality for real time aged products. Radiation stability improvement was tried by incorporating light protectors and antioxidants into polypropylene homopolymer. A composition with added light protector was obtained that did not discolor and that kept mechanical stability during aging. Polyvinylchloride tubing was examined and found stable in comparison with imported materials. A non-discoloring product could not be obtained. Evaluation of local commercial polyvinylchloride insulations of wires similar to the wires used in the conveyor system of the Irradiation Facility of Ezeiza Atomic Center suggested that the limit of 50 % reduction in elongation to break in relation to control samples as an indication of failure is too conservative, because this limit was reached much earlier than the actual period of use of installed wires. (author)

  18. Structure of a radiate pseudocolony associated with an intrauterine contraceptive device

    International Nuclear Information System (INIS)

    O'Brien, P.K.; Lea, P.J.; Roth-Moyo, L.A.

    1985-01-01

    Transmission electron microscopy of a radiate pseudocolony associated with an intrauterine contraceptive device (IUCD) showed central bundles of extracellular fibers averaging 35 nm in diameter, surrounded by layered mantles of electron-dense, amorphous granular material. No bacterial, viral, or fungal structures were present. X-ray microanalysis revealed copper, sulfur, chloride, iron, and phosphorus; no calcium was found. It is postulated that these structures and histologically identical non-IUCD-associated granules from the female genital tract, as well as similar structures from other body locations, including those reported in colloid cysts of the third ventricle, are of lipofuscin origin

  19. Radiation leakage monitoring method and device from primary to secondary coolant systems in nuclear reactor

    International Nuclear Information System (INIS)

    Tajiri, Yoshiaki; Umehara, Toshihiro; Yamada, Masataka.

    1993-01-01

    The present invention monitors radiation leaked from any one of primary cooling systems to secondary cooling systems in a plurality of steam generators. That is, radiation monitoring means each corresponding to steam each generators are disposed to the upstream of a position where main steam pipes are joined. With such a constitution, since the detection object of each of radiation monitoring means is secondary coolants before mixing with secondary coolants of other secondary loops or dilution, lowering of detection accuracy can be avoided. Except for the abnormal case, that is, a case neither of radiation leakage nor of background change, the device is adapted as a convenient measuring system only with calculation performance. Once abnormality occurs, a loop having a value exceeding a standard value is identified by a single channel analyzer function. The amount of radiation leakage from the steam generator belonging to the specified loop is monitored quantitatively by a multichannel analyzer function. According to the method of the present invention, since specific spectrum analysis is conducted upon occurrence of abnormality, presence of radiation leakage and the scale thereof can be judged rapidly. (I.S.)

  20. Study of bremsstrahlung dose fields in radiation shield and labyrinth devices of plants with LUEH-8/5B accelerator

    International Nuclear Information System (INIS)

    Vikulin, A.A.; Vanyushkin, B.M.; Garnyk, D.V.; Kon'kov, N.G.; Terent'ev, B.M.

    1980-01-01

    Measurement results of exposure dose rate (EDR) of radiation in fields of bremsstrahlung of radiation plants with LUEh-8/5B linear accelerator of electrons by means of DRG2-03 dose meter, intended for operative measuring EDR in high intense fields of γ-radiation of powerful radioisotopic plants, are presented. Dose meter design is described. Measurements of bremsstrahlung EDR have been carried out in the chamber of plant irradiation for radiation sterilizing medical items, as well as in the chamber of VNIIRT experimental plant. RUP-1 device has been used for measuring radiation EDR in a labyrinth behind 1.8 m thick shoulder by concrete [ru

  1. Detection of Terahertz Radiation

    DEFF Research Database (Denmark)

    2015-01-01

    The present invention relates to a system for detecting terahertz radiation, a camera device, and a method for detecting terahertz radiation.......The present invention relates to a system for detecting terahertz radiation, a camera device, and a method for detecting terahertz radiation....

  2. A NOVEL SUPPORT DEVICE FOR HEAD IMMOBILIZATION DURING RADIATION THERAPY THAT IS APPLICABLE TO BOTH CATS AND DOGS.

    Science.gov (United States)

    Nemoto, Yuki; Maruo, Takuya; Fukuyama, Yasuhiro; Kawarai, Shinpei; Shida, Takuo; Nakayama, Tomohiro

    2015-01-01

    Repeatable head immobilization is important for minimizing positioning error during radiation therapy for veterinary patients with head neoplasms. The purpose of this retrospective cross-sectional study was to describe a novel technique for head immobilization (Device II) and compare this technique with a previously described technique (Device I). Device II provided additional support by incorporating three teeth (vs. two teeth with Device I). Between 2011 and 2013, both devices were applied in clinically affected cats (Device I, n = 17; Device II, n = 11) and dogs (Device I, n = 85; Device II, n = 22) of various breeds and sizes. The following data were recorded for each included patient: variability in the angle of the skull (roll, yaw, and pitch), coordinates of the isocenter, and distance from the reference mark to the tumor. Devices I and II differed for skull angle variability during the treatment of dogs (roll, P = 0.0007; yaw, P = 0.0018; pitch, P = 0.0384) and for yaw of during the treatment of cats (P patients. © 2015 American College of Veterinary Radiology.

  3. Order No.104 relating to the competence of the Institute for Radiation Protection made on 14 February 1975

    International Nuclear Information System (INIS)

    1975-01-01

    Order 104 made in implementation of Section 3 of Act No 174 of 26 April 1957 on Radiation Protection was published in the Finnish Official Gazette No 100-109 of 18 February 1975 and came into force on 1 March 1975. It lays down that the Institute is competent for issuing the licences, which under Section 2 of the Act, are required for the production, transport, import, export, possession and trade in radioactive substances, as well as for the use of all radiation-generating facilities and equipment, except for those needed for medical purposes. Licences concerning activities referred to in the Atomic Energy Act of 25 october 1957 will continue to be issued by the Ministry of Trade and Industry. (NEA) [fr

  4. Study of radiation-induced leakage current between adjacent devices in a CMOS integrated circuit

    Institute of Scientific and Technical Information of China (English)

    Ding Lili; Guo Hongxia; Chen Wei; Fan Ruyu

    2012-01-01

    Radiation-induced inter-device leakage is studied using an analytical model and TCAD simulation.There were some different opinions in understanding the process of defect build-up in trench oxide and parasitic leakage path turning on from earlier studies.To reanalyze this problem and make it beyond argument,every possible variable is considered using theoretical analysis,not just the change of electric field or oxide thickness independently.Among all possible inter-device leakage paths,parasitic structures with N-well as both drain and source are comparatively more sensitive to the total dose effect when a voltage discrepancy exists between the drain and source region.Since N-well regions are commonly connected to the same power supply,these kinds of structures will not be a problem in a real CMOS integrated circuit.Generally speaking,conduction paths of inter-device leakage existing in a real integrated circuit and under real electrical circumstances are not very sensitive to the total ionizing dose effect.

  5. 1. Partial licence (new) for the Muelheim-Kaerlich reactor. BVG (German Federal Administrative Court), decision of 14. January 1998, Az.: 11 C 13.96

    International Nuclear Information System (INIS)

    1998-01-01

    The matter to be decided by the BVG, the highest administrative court of Germany, was the competence of the licensing authority for risk assessment in the licensing procedure and its duty to perform risk assessment with reference to current state of the art in nuclear science and technology, in compliance with the Atomic Energy Act, section 7, sub-section 2, No. 3. Performance of risk assessment falling short of the requirements of the Atomic Energy Act is a cause for rescission of an operating licence or partial licence. This was the cause presented by complaining parties in legal proceedings at a lower court, referring to deficits in terms of technology (seismic risks assessment), and in terms of law. The partial construction licence was repealed by the lower court. The BVG court had to perform judicial review of an appeal logded by the reactor operators from the judgment passed by the lower court and relates exclusively to aspects of substantive law, as the Atomic Energy Act attributes priority of competence for decisions about technological aspects and contents of reactor licences to the licensing authority. The BVG dismissed the appeal for absence of defects in substantive law; the decision is non-appealable. (CB) [de

  6. Radiation (Safety Control) Ordinance 1978

    International Nuclear Information System (INIS)

    1978-01-01

    This Ordinance provides for the control, regulation, possession, use and transport of radioactive substance and irradiating apparatus. The Director of Health is responsible for administration of the Ordinance, which contains detailed provisions concerning the terms and conditions of licences, duties of licensees, medical examinations, maximum radiation doses, precautions to be taken to avoid exceeding such doses. The Ordinance also lays down a system of record-keeping and registration as well as packaging specifications for the transport of radioactive substances. (NEA) [fr

  7. Radiation effects in semiconductors

    CERN Document Server

    2011-01-01

    There is a need to understand and combat potential radiation damage problems in semiconductor devices and circuits. Written by international experts, this book explains the effects of radiation on semiconductor devices, radiation detectors, and electronic devices and components. These contributors explore emerging applications, detector technologies, circuit design techniques, new materials, and innovative system approaches. The text focuses on how the technology is being used rather than the mathematical foundations behind it. It covers CMOS radiation-tolerant circuit implementations, CMOS pr

  8. Use of radiation and radiation practices 1994. Events and statistics

    International Nuclear Information System (INIS)

    Havukainen, R.

    1995-05-01

    In Finland, there were 1,745 valid safety licences for the use of radiation at the end of 1994. In addition, 2,050 sites were included in the compulsory registration for dental x-ray diagnostics. The register of the Finnish Centre for Radiation and Nuclear Safety listed 12,794 radiation sources and 316 radionuclide laboratories. The import of radioactive substances amounted to 4.6x10 15 Bq and export to 2.2x10 13 Bq. A total of 1.4x10 13 Bq of short-lived radionuclides were produced in Finland. Workers monitored for radiation exposure included 11,147 employees on 1,294 work sites. Of these, 27% received an annual dose exceeding the recording threshold. The total dose recorded in the dose register (sum of personal dosemeter readings) was 75 man Sv in 1994, nuclear power plant employees accounting for 70% of this total. The annual dosemeter reading of ten medical doctors (radiologists, international radiologists and cardiologists) and five nuclear power plant employees was equal to or in excess of 20 mSv. Effective dose, however, did not exceed the dose limit of 50 mSv established for a one-year monitoring period

  9. Nationallizenzen - ein Desiderat in Österreich / National licences: a desideratum in Austria

    Directory of Open Access Journals (Sweden)

    Bauer, Bruno

    2007-12-01

    Full Text Available In Germany national licences are funded by the "Deutsche Forschungsgemeinschaft (DFG" as part of their system for nationwide literature supply. In contrast there is no comparable scheme and no central office to finance and foster research information infrastructure in Austria. Universities in Austria obviously suffer more and more from the lack of backfile archives particularly in the field of e-journals and literature databases. Out of this in 2007 the task force "ARGE Bibliotheksdirektor/-innen" started to pull the attention of university steering boards and political decision-makers towards this important topic which is critical for science and research in Austria. The initiative is supported by the "Kooperation e-Media Österreich".

  10. Superconducting (radiation hardened) magnets for mirror fusion devices

    International Nuclear Information System (INIS)

    Henning, C.D.; Dalder, E.N.C.; Miller, J.R.; Perkins, J.R.

    1983-01-01

    Superconducting magnets for mirror fusion have evolved considerably since the Baseball II magnet in 1970. Recently, the Mirror Fusion Test Facility (MFTF-B) yin-yang has been tested to a full field of 7.7 T with radial dimensions representative of a full scale reactor. Now the emphasis has turned to the manufacture of very high field solenoids (choke coils) that are placed between the tandem mirror central cell and the yin-yang anchor-plug set. For MFTF-B the choke coil field reaches 12 T, while in future devices like the MFTF-Upgrade, Fusion Power Demonstration and Mirror Advanced Reactor Study (MARS) reactor the fields are doubled. Besides developing high fields, the magnets must be radiation hardened. Otherwise, thick neutron shields increase the magnet size to an unacceptable weight and cost. Neutron fluences in superconducting magnets must be increased by an order of magnitude or more. Insulators must withstand 10 10 to 10 11 rads, while magnet stability must be retained after the copper has been exposed to fluence above 10 19 neutrons/cm 2

  11. Reusable radiation monitor

    International Nuclear Information System (INIS)

    Fanselow, D.L.; Ersfeld, D.A.

    1978-01-01

    An integrating, reusable device for monitoring exposure to actinic radiation is disclosed. The device comprises a substrate having deposited thereon at least one photochromic aziridine compound which is sealed in an oxygen barrier to stabilize the color developed by the aziridine compound in response to actinic radiation. The device includes a spectral response shaping filter to transmit only actinic radiation of the type being monitored. A color standard is also provided with which to compare the color developed by the aziridine compound

  12. Use of mobile device technology to continuously collect patient-reported symptoms during radiation therapy for head and neck cancer: A prospective feasibility study.

    Science.gov (United States)

    Falchook, Aaron D; Tracton, Gregg; Stravers, Lori; Fleming, Mary E; Snavely, Anna C; Noe, Jeanne F; Hayes, David N; Grilley-Olson, Juneko E; Weiss, Jared M; Reeve, Bryce B; Basch, Ethan M; Chera, Bhishamjit S

    2016-01-01

    Accurate assessment of toxicity allows for timely delivery of supportive measures during radiation therapy for head and neck cancer. The current paradigm requires weekly evaluation of patients by a provider. The purpose of this study is to evaluate the feasibility of monitoring patient reported symptoms via mobile devices. We developed a mobile application for patients to report symptoms in 5 domains using validated questions. Patients were asked to report symptoms using a mobile device once daily during treatment or more often as needed. Clinicians reviewed patient-reported symptoms during weekly symptom management visits and patients completed surveys regarding perceptions of the utility of the mobile application. The primary outcome measure was patient compliance with mobile device reporting. Compliance is defined as number of days with a symptom report divided by number of days on study. There were 921 symptom reports collected from 22 patients during treatment. Median reporting compliance was 71% (interquartile range, 45%-80%). Median number of reports submitted per patient was 34 (interquartile range, 21-53). Median number of reports submitted by patients per week was similar throughout radiation therapy and there was significant reporting during nonclinic hours. Patients reported high satisfaction with the use of mobile devices to report symptoms. A substantial percentage of patients used mobile devices to continuously report symptoms throughout a course of radiation therapy for head and neck cancer. Future studies should evaluate the impact of mobile device symptom reporting on improving patient outcomes.

  13. Relative risk analysis in regulating the use of radiation-emitting medical devices. A preliminary application

    Energy Technology Data Exchange (ETDEWEB)

    Jones, E.D.; Banks, W.W.; Altenbach, T.J.; Fischer, L.E. [Lawrence Livermore National Lab., CA (United States)

    1995-09-01

    This report describes a preliminary application of an analysis approach for assessing relative risks in the use of radiation- emitting medical devices. Results are presented on human-initiated actions and failure modes that are most likely to occur in the use of the Gamma Knife, a gamma irradiation therapy device. This effort represents an initial step in a US Nuclear Regulatory Commission (NRC) plan to evaluate the potential role of risk analysis in regulating the use of nuclear medical devices. For this preliminary application of risk assessment, the focus was to develop a basic process using existing techniques for identifying the most likely risk contributors and their relative importance. The approach taken developed relative risk rankings and profiles that incorporated the type and quality of data available and could present results in an easily understood form. This work was performed by the Lawrence Livermore National Laboratory for the NRC.

  14. Relative risk analysis in regulating the use of radiation-emitting medical devices. A preliminary application

    International Nuclear Information System (INIS)

    Jones, E.D.; Banks, W.W.; Altenbach, T.J.; Fischer, L.E.

    1995-09-01

    This report describes a preliminary application of an analysis approach for assessing relative risks in the use of radiation- emitting medical devices. Results are presented on human-initiated actions and failure modes that are most likely to occur in the use of the Gamma Knife, a gamma irradiation therapy device. This effort represents an initial step in a US Nuclear Regulatory Commission (NRC) plan to evaluate the potential role of risk analysis in regulating the use of nuclear medical devices. For this preliminary application of risk assessment, the focus was to develop a basic process using existing techniques for identifying the most likely risk contributors and their relative importance. The approach taken developed relative risk rankings and profiles that incorporated the type and quality of data available and could present results in an easily understood form. This work was performed by the Lawrence Livermore National Laboratory for the NRC

  15. Modeling of radiation-induced charge trapping in MOS devices under ionizing irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Petukhov, M. A., E-mail: m.a.petukhov@gmail.com; Ryazanov, A. I. [National Research Center Kurchatov Institute (Russian Federation)

    2016-12-15

    The numerical model of the radiation-induced charge trapping process in the oxide layer of a MOS device under ionizing irradiation is developed; the model includes carrier transport, hole capture by traps in different states, recombination of free electrons and trapped holes, kinetics of hydrogen ions which can be accumulated in the material during transistor manufacture, and accumulation and charging of interface states. Modeling of n-channel MOSFET behavior under 1 MeV photon irradiation is performed. The obtained dose dependences of the threshold voltage shift and its contributions from trapped holes and interface states are in good agreement with experimental data.

  16. Use of mobile device technology to continuously collect patient-reported symptoms during radiation therapy for head and neck cancer: A prospective feasibility study

    Directory of Open Access Journals (Sweden)

    Aaron D. Falchook, MD

    2016-04-01

    Conclusions: A substantial percentage of patients used mobile devices to continuously report symptoms throughout a course of radiation therapy for head and neck cancer. Future studies should evaluate the impact of mobile device symptom reporting on improving patient outcomes.

  17. Device for detecting ionizing radiation

    International Nuclear Information System (INIS)

    Anatychuk, L.I.; Kharitonov, J.P.; Kusniruk, V.F.; Meir, V.A.; Melnik, A.P.; Ponomarev, V.S.; Skakodub, V.A.; Sokolov, A.D.; Subbotin, V.G.; Zhukovsky, A.N.

    1980-01-01

    The present invention relates to ionizing radiation sensors, and , more particularly, to semiconductor spectrometers with thermoelectric cooling, and can most advantageously be used in mineral raw material exploration and evaluation under field conditions. The spectrometer comprises a vacuum chamber with an entrance window for passing the radiation therethrough. The vacuum chamber accommodates a thermoelectric cooler formed by a set of peltier elements. A heat conducting plate is mounted on the cold side of the thermoelectric cooler, and its hot side is provided with a radiator. Mounted on the heat conducting plate are sets of peltier elements, integral with the thermoelectric cooler and independent of one another. The peltier elements of these sets are stacked so as to develop the minimum temperature conditions on one set carrying a semiconductor detector and to provide the maximum refrigeration capacity conditions on the other set provided with the field-effect transistor mounted thereon

  18. Decision 99-18: Range Petroleum Corporation application for a well licence, Sturgeon Lake Area

    International Nuclear Information System (INIS)

    1999-07-01

    Range Petroleum Corporation (Range) applied to the Alberta Energy and Utilities Board (EUB) pursuant to Section 2.020 of the Oil and Gas Conservation Regulations for a well licence to drill a sour oil well from a surface location in Legal Subdivision 4, Section 34, West of the fifth Meridian, directionally to a bottom-hole location under Sturgeon Lake. The purpose of the proposed well would be to obtain sour oil production from the Leduc Formation. The well would be a Level 1 well because it would have a potential maximum hydrogen sulphide release rate of 0.0412 cubic m/s. The EUB received objections to the application from landowners, cattle ranchers, farmers, residents, and cottage owners in the area of the proposed well. The application and intervention were considered at a public hearing on 26 January 1999 in Grande Prairie, Alberta, and the Board viewed the proposed surface location, the previous Lds 3-2 surface location, and the surrounding area prior to the hearing. Having carefully considered the evidence, the Board believed that it would be possible to drill the proposed well safely and with minimal risk, subject to attached conditions. But in light of the unique setting of the area, including the residences and the road and lake configurations, and the difficulty that would exist preparing an effective environmental review process (ERP), the Board deferred its decision on the well licence application until an approved ERP is in place

  19. Radiation Hardness tests with neutron flux on different Silicon photomultiplier devices

    Science.gov (United States)

    Cattaneo, P. W.; Cervi, T.; Menegolli, A.; Oddone, M.; Prata, M.; Prata, M. C.; Rossella, M.

    2017-07-01

    Radiation hardness is an important requirement for solid state readout devices operating in high radiation environments common in particle physics experiments. The MEG II experiment, at PSI, Switzerland, investigates the forbidden decay μ+ → e+ γ. Exploiting the most intense muon beam of the world. A significant flux of non-thermal neutrons (kinetic energy Ek>= 0.5 MeV) is present in the experimental hall produced along the beam-line and in the hall itself. We present the effects of neutron fluxes comparable to the MEG II expected doses on several Silicon Photomultiplier (SiPMs). The tested models are: AdvanSiD ASD-NUV3S-P50 (used in MEG II experiment), AdvanSiD ASD-NUV3S-P40, AdvanSiD ASD-RGB3S-P40, Hamamatsu and Excelitas C30742-33-050-X. The neutron source is the thermal Sub-critical Multiplication complex (SM1) moderated with water, located at the University of Pavia (Italy). We report the change of SiPMs most important electric parameters: dark current, dark pulse frequency, gain, direct bias resistance, as a function of the integrated neutron fluency.

  20. Radiation and detectors introduction to the physics of radiation and detection devices

    CERN Document Server

    Cerrito, Lucio

    2017-01-01

    This textbook provides an introduction to radiation, the principles of interaction between radiation and matter, and the exploitation of those principles in the design of modern radiation detectors. Both radiation and detectors are given equal attention and their interplay is carefully laid out with few assumptions made about the prior knowledge of the student. Part I is dedicated to radiation, broadly interpreted in terms of energy and type, starting with an overview of particles and forces, an extended review of common natural and man-made sources of radiation, and an introduction to particle accelerators. Particular attention is paid to real life examples, which place the types of radiation and their energy in context. Dosimetry is presented from a modern, user-led point of view, and relativistic kinematics is introduced to give the basic knowledge needed to handle the more formal aspects of radiation dynamics and interaction. The explanation of the physics principles of interaction between radiation an...

  1. Solid state radiation dosimetry

    International Nuclear Information System (INIS)

    Moran, P.R.

    1976-01-01

    Important recent developments provide accurate, sensitive, and reliable radiation measurements by using solid state radiation dosimetry methods. A review of the basic phenomena, devices, practical limitations, and categories of solid state methods is presented. The primary focus is upon the general physics underlying radiation measurements with solid state devices

  2. Discrete Event Simulation Model of the Polaris 2.1 Gamma Ray Imaging Radiation Detection Device

    Science.gov (United States)

    2016-06-01

    release; distribution is unlimited DISCRETE EVENT SIMULATION MODEL OF THE POLARIS 2.1 GAMMA RAY IMAGING RADIATION DETECTION DEVICE by Andres T...ONLY (Leave blank) 2. REPORT DATE June 2016 3. REPORT TYPE AND DATES COVERED Master’s thesis 4. TITLE AND SUBTITLE DISCRETE EVENT SIMULATION MODEL...modeled. The platform, Simkit, was utilized to create a discrete event simulation (DES) model of the Polaris. After carefully constructing the DES

  3. Regulation of radiation sources in Canada

    International Nuclear Information System (INIS)

    Brown, W.R.

    1989-04-01

    This paper describes in general the Canadian program for the regulation of radiation sources, with particular emphasis on radioisotope licences. The Atomic Energy Control Board is described, as are the most significant parts of the Regulations. Licensing, which is the method chosen for control, is explained by describing the assessment of an application through the enforcement of the requirements, and the overall effectiveness of the program is measured by analyzing the incidents and overexposures that have occurred in recent years

  4. Improved Understanding of Space Radiation Effects on Exploration Electronics by Advanced Modeling of Nanoscale Devices and Novel Materials, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Future NASA space exploration missions will use nanometer-scale electronic technologies which call for a shift in how radiation effects in such devices and materials...

  5. Evaluation of a hand-held far-ultraviolet radiation device for decontamination of Clostridium difficile and other healthcare-associated pathogens

    Directory of Open Access Journals (Sweden)

    Nerandzic Michelle M

    2012-05-01

    Full Text Available Abstract Background Environmental surfaces play an important role in transmission of healthcare-associated pathogens. There is a need for new disinfection methods that are effective against Clostridium difficile spores, but also safe and rapid. The Sterilray™ Disinfection Wand device is a hand-held room decontamination technology that utilizes far-ultraviolet radiation (185-230 nm to kill pathogens. Methods We examined the efficacy of disinfection using the Sterilray device in the laboratory, in rooms of hospitalized patients, and on surfaces outside of patient rooms (i.e. keyboards and portable medical equipment. Cultures for C. difficile, methicillin-resistant Staphylococcus aureus (MRSA, and vancomycin-resistant Enterococcus (VRE were collected from commonly-touched surfaces before and after use of the Sterilray device. Results On inoculated surfaces in the laboratory, application of the Sterilray device at a radiant dose of 100 mJ/cm2 for ~ 5 seconds consistently reduced recovery of C. difficile spores by 4.4 CFU log10, MRSA by 5.4 log10CFU and of VRE by 6.9 log10CFU. A >3 log10 reduction of MRSA and VRE was achieved in ~2 seconds at a lower radiant dose, but killing of C. difficile spores was significantly reduced. On keyboards and portable medical equipment that were inoculated with C. difficile spores, application of the Sterilray device at a radiant dose of 100���mJ/cm2 for ~ 5 seconds reduced contamination by 3.2 log10CFU. However, the presence of organic material reduced the lethal effect of the far-UV radiation. In hospital rooms that were not pre-cleaned, disinfection with the Sterilray device significantly reduced the frequency of positive C. difficile and MRSA cultures (P =0.007. Conclusions The Sterilray™ Disinfection Wand is a novel environmental disinfection technology that rapidly kills C. difficile spores and other healthcare-associated pathogens on surfaces. However, the presence of organic matter

  6. Proceedings of the 3rd international workshop on radiation effects on semiconductor devices for space application

    International Nuclear Information System (INIS)

    1998-10-01

    This publication is the collection of the paper presented at the title workshop. The main purpose of the workshop is to bring the chance for exchange of information between scientists and engineers who work in the field of research and development of semiconductor devices used in strong radiation environment in space. The 27 of the presented papers are indexed individually. (J.P.N.)

  7. Modèle d'édition et autre modèle d'octroi de licences (PALM Africa ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Publishing and Alternative Licensing Model of Africa (PALM Africa) veut améliorer l'accès au matériel didactique grâce à des règles plus souples en matière d'octroi de licences. Grâce à cette subvention, PALM Africa pourra ... models : South Africa. Download PDF. Studies. Licensing, publishing and new business models.

  8. RF and dc desensitized electroexplosive device

    Science.gov (United States)

    Krainiak, John W.; Speaks, Paul D.; Cornett, Michael S.

    1989-07-01

    This patent application relates to electroexplosive devices (EEDs) such as detonators, blasting caps and squibs, in particular to a method and device for desensitizing EEDs to electromagnetic radiation and electrostatic charges with the added ability to desensitize the device to essentially dc currents. An insensitive electroexplosive device to electrically ignite explosive is disclosed. This device is inherently immune to radio frequency (RF) radiation, and also provides protection against dc or very low frequency RF induced by arcing. A central feature is use of zeners and capacitors to form a reactively balanced bridge circuit. When constructed in semiconductor form, as described in this application, the device is capable of incorporation in small caliber ordnance.

  9. Incore monitoring device

    International Nuclear Information System (INIS)

    Tai, Ichiro; Shirayama, Shin-pei; Nozaki, Shin-ichi.

    1978-01-01

    Purpose: To provide an incore monitoring device wherein both radiation monitoring and acoustic monitoring are carried out simultaneously by one detector, whereby installation of the device and signal pick-up are facilitated. Incore conditions are accurately grasped. Constitution: When a neutron is irradiated in a state where a DC voltage is applied between the electrode and the vessel in the device, an ionization current is occured by (n.γ) reaction of the transformed substance as in an ionization chamber, Accordingly, a voltage drop occurs at both ends of the resistor of the radiation signal processing system, as a result of which a neutron flux can be detected. Further, when a sound is generated in the reactor, the monitoring device bottom wall which formed by a piezoelectric element detects the sound-waves. This output signal is picked up by the acoustic signal processing system to judge the generation of sound. (Aizawa, K.)

  10. Irradiation device

    International Nuclear Information System (INIS)

    Suzuki, Toshimitsu.

    1989-01-01

    In an irradiation device for irradiating radiation rays such as electron beams to pharmaceuticals, etc., since the distribution of scanned electron rays was not monitored, the electron beam intensity could be determined only indirectly and irradiation reliability was not satisfactory. In view of the above, a plurality of monitor wires emitting secondary electrons are disposed in the scanning direction near a beam take-out window of a scanning duct, signals from the monitor wires are inputted into a display device such as a cathode ray tube, as well as signals from the monitor wires at the central portion are inputted into counting rate meters to measure the radiation dose as well. Since secondary electrons are emitted when electron beams pass through the monitor wires and the intensity thereof is in proportion with the intensity of incident electron beams, the distribution of the radiation dose can be monitored by measuring the intensity of the emitted secondary electrons. Further, uneven irradiation, etc. can also be monitored to make the radiation of irradiation rays reliable. (N.H.)

  11. Setup reproducibility in radiation therapy for lung cancer: a comparison between T-bar and expanded foam immobilization devices

    International Nuclear Information System (INIS)

    Halperin, Ross; Roa, Wilson; Field, Melissa; Hanson, John; Murray, Brad

    1999-01-01

    Purpose: Physiologic and non-physiologic tumor motion complicates the use of tight margins in three-dimensional (3D) conformal radiotherapy. Setup reproducibility is an important non-physiologic cause of tumor motion. The objective of this study is to evaluate and compare patient setup reproducibility using the reusable T-bar and the disposable expanded foam immobilization device (EFID) in radiation therapy for lung cancer. Methods and Materials: Two hundred forty-four portal films were taken from 16 prospectively accrued patients treated for lung cancer. Patients were treated with either a pair of anterior and posterior parallel opposing fields (POF), or a combination of POF and a three-field isocentric technique. Each patient was treated in a supine position using either the T-bar setup or EFID. Six patients were treated in both devices over their treatment courses. Field placement analysis was used to evaluate 3D setup reproducibility, by comparing positions of bony landmarks relative to the radiation field edges in digitized simulator and portal images. Anterior-posterior, lateral, and longitudinal displacements, as well as field rotations along coronal and sagittal planes were measured. Statistical analyses of variance were applied to the deviations among portal films of all patients and the subgroup treated with both immobilization methods. Results: For the T-bar immobilization device, standard deviations of the setup reproducibility were 5.1, 3.7, and 5.1 mm in the anterior-posterior, lateral, and longitudinal dimensions, respectively. Rotations in the coronal plane and the sagittal plane were 0.9 deg. and 1.0 deg. , respectively. For the EFID, corresponding standard deviations of set up reproducibility were 3.6 mm, 5.3 mm, 5.4 mm, 0.7 deg. and 1.4 deg. , respectively. There was no statistically significant difference (p = 0.22) in the 3D setup reproducibility between T-bar and EFID. Subgroup analysis for the patients who were treated with both

  12. The signature-based radiation-scanning approach to standoff detection of improvised explosive devices

    International Nuclear Information System (INIS)

    Brewer, R.L.; Dunn, W.L.; Heider, S.; Matthew, C.; Yang, X.

    2012-01-01

    The signature-based radiation-scanning technique for detection of improvised explosive devices is described. The technique seeks to detect nitrogen-rich chemical explosives present in a target. The technology compares a set of “signatures” obtained from a test target to a collection of “templates”, sets of signatures for a target that contain an explosive in a specific configuration. Interrogation of nitrogen-rich fertilizer samples, which serve as surrogates for explosives, is shown experimentally to be able to discriminate samples of 3.8 L and larger. - Highlights: ► Signature-based radiation-scanning techniques applied to detection of explosives. ► Nitrogen-rich fertilizer samples served as surrogate explosive samples. ► Signatures of a target compared to collections of templates of surrogate explosives. ► Figure-of-merit determined for neutron and neutron-induced gamma-ray signatures. ► Discrimination of surrogate explosive from inert samples of 3.8 L and larger.

  13. Radiation hardness assurances categories for COTS technologies

    International Nuclear Information System (INIS)

    Hash, G.L.; Shaneyfelt, M.R.; Sexton, F.W.; Winokur, P.S.

    1997-01-01

    A comparison of the radiation tolerance of three commercial, and one radiation hardened SRAM is presented for four radiation environments. This work has shown the difficulty associated with strictly categorizing a device based solely on its radiation response, since its category depends on the specific radiation environment considered. For example, the 3.3-V Paradigm SRAM could be considered a radiation-tolerant device except for its SEU response. A more useful classification depends on the methods the manufacturer uses to ensure radiation hardness, i.e. whether specific design and process techniques have been used to harden the device. Finally, this work has shown that burned-in devices may fail functionally as much as 50% lower in total dose environments than non-burned-in devices. No burn-in effect was seen in dose-rate upset, latchup, or SEE environments. The user must ensure that total dose lot acceptance testing was performed on burned-in devices

  14. Improvements in or relating to semiconductor devices

    Energy Technology Data Exchange (ETDEWEB)

    Pepper, M

    1981-08-26

    A method of testing a field effect device for radiation hardness is described which does not involve irradiating the device. In a low temperature environment the conductance of the device is measured as a function of gate voltage at a first and at a second different substrate bias potential and by comparing the two an assessment of radiation hardness is made.

  15. Radiation safety

    International Nuclear Information System (INIS)

    Van Riessen, A.

    2002-01-01

    Full text: Experience has shown that modem, fully enclosed, XRF and XRD units are generally safe. This experience may lead to complacency and ultimately a lowering of standards which may lead to accidents. Maintaining awareness of radiation safety issues is thus an important role for all radiation safety officers. With the ongoing progress in technology, a greater number of radiation workers are more likely to use a range of instruments/techniques - eg portable XRF, neutron beam analysis, and synchrotron radiation analysis. The source for each of these types of analyses is different and necessitates an understanding of the associated dangers as well as use of specific radiation badges. The trend of 'suitcase science' is resulting in scientists receiving doses from a range of instruments and facilities with no coordinated approach to obtain an integrated dose reading for an individual. This aspect of radiation safety needs urgent attention. Within Australia a divide is springing up between those who work on Commonwealth property and those who work on State property. For example a university staff member may operate irradiating equipment on a University campus and then go to a CSIRO laboratory to operate similar equipment. While at the University State regulations apply and while at CSIRO Commonwealth regulations apply. Does this individual require two badges? Is there a need to obtain two licences? The application of two sets of regulations causes unnecessary confusion and increases the workload of radiation safety officers. Radiation safety officers need to introduce risk management strategies to ensure that both existing and new procedures result in risk minimisation. A component of this strategy includes ongoing education and revising of regulations. AXAA may choose to contribute to both of these activities as a service to its members as well as raising the level of radiation safety for all radiation workers. Copyright (2002) Australian X-ray Analytical

  16. Transmedia storytelling : quand l’histoire se conçoit et se construit comme une licence

    OpenAIRE

    Bahuaud, Myriam

    2015-01-01

    Myriam Bahuaud tente de mettre en lien les théories du licensing, de l’économie des produits dérivés et du transmedia storytelling selon la définition de Henry Jenkins. En détaillant les stratégies des licences liées au monde de l’enfance, elle met l’accent sur l’importance des logiques marketing et culturelles dans le phénomène du licensing.

  17. Use of radiation and radiation practices 1994. Events and statistics

    Energy Technology Data Exchange (ETDEWEB)

    Havukainen, R. [ed.

    1995-05-01

    In Finland, there were 1,745 valid safety licences for the use of radiation at the end of 1994. In addition, 2,050 sites were included in the compulsory registration for dental x-ray diagnostics. The register of the Finnish Centre for Radiation and Nuclear Safety listed 12,794 radiation sources and 316 radionuclide laboratories. The import of radioactive substances amounted to 4.6x10{sup 15} Bq and export to 2.2x10{sup 13} Bq. A total of 1.4x10{sup 13} Bq of short-lived radionuclides were produced in Finland. Workers monitored for radiation exposure included 11,147 employees on 1,294 work sites. Of these, 27% received an annual dose exceeding the recording threshold. The total dose recorded in the dose register (sum of personal dosemeter readings) was 75 man Sv in 1994, nuclear power plant employees accounting for 70% of this total. The annual dosemeter reading of ten medical doctors (radiologists, international radiologists and cardiologists) and five nuclear power plant employees was equal to or in excess of 20 mSv. Effective dose, however, did not exceed the dose limit of 50 mSv established for a one-year monitoring period.

  18. Studies of radiation hardness of MOS devices for application in a linear collider vertex detector

    Energy Technology Data Exchange (ETDEWEB)

    Wei, Qingyu

    2008-10-17

    The proposed International Linear Collider (ILC) together with the Large Hadron Collider (LHC) at CERN serve as a combined tool to explore the mysteries of the universe: the former is a precision machine and the latter can be considered as a finding machine. The key component of the ILC is the vertex detector that should be placed as close as possible to the Interaction Point (IP) and has better radiation tolerance against the dominant electron-positron pair production background from beam-beam interactions. A new generation of MOS-type Depleted-Field-Effect Transistor (MOSDEPFET) active pixel detectors has been proposed and developed by Semiconductor Labor Munich for Physics and for extraterrestrial Physics in order to meet the requirements of the vertex detector at the ILC. Since all MOS devices are susceptible to ionizing radiation, the main topic is focused on the radiation hardness of detectors, by which a series of physical processes are analyzed: e.g. surface damage due to ionizing radiation as well as damage mechanisms and their associated radiation effects. As a consequence, the main part of this thesis consists of a large number of irradiation experiments and the corresponding discussions. Finally, radiation hardness of the detectors should be improved through a set of concluded experiences that are based on a series of analysis of the characteristic parameters using different measurement techniques. The feasibility of the MOSDEPFET-based vertex detector is, therefore, predicted at ILC. (orig.)

  19. Studies of radiation hardness of MOS devices for application in a linear collider vertex detector

    International Nuclear Information System (INIS)

    Wei, Qingyu

    2008-01-01

    The proposed International Linear Collider (ILC) together with the Large Hadron Collider (LHC) at CERN serve as a combined tool to explore the mysteries of the universe: the former is a precision machine and the latter can be considered as a finding machine. The key component of the ILC is the vertex detector that should be placed as close as possible to the Interaction Point (IP) and has better radiation tolerance against the dominant electron-positron pair production background from beam-beam interactions. A new generation of MOS-type Depleted-Field-Effect Transistor (MOSDEPFET) active pixel detectors has been proposed and developed by Semiconductor Labor Munich for Physics and for extraterrestrial Physics in order to meet the requirements of the vertex detector at the ILC. Since all MOS devices are susceptible to ionizing radiation, the main topic is focused on the radiation hardness of detectors, by which a series of physical processes are analyzed: e.g. surface damage due to ionizing radiation as well as damage mechanisms and their associated radiation effects. As a consequence, the main part of this thesis consists of a large number of irradiation experiments and the corresponding discussions. Finally, radiation hardness of the detectors should be improved through a set of concluded experiences that are based on a series of analysis of the characteristic parameters using different measurement techniques. The feasibility of the MOSDEPFET-based vertex detector is, therefore, predicted at ILC. (orig.)

  20. Main radiation protection actions for medical personnel as primary responders front of an event with radiological dispersive device

    International Nuclear Information System (INIS)

    Duque, Hildanielle Ramos

    2015-01-01

    After the terrorist attack in New York, USA, in 2001, there was a worldwide concern about possible attacks using radioactive material in conventional detonators, called as Radiological Dispersal Device (RDD) or 'dirty bomb'. Several studies have been and are being made to form a global knowledge about this type of event. As until now, fortunately, there has not been an event with RDD, the Goiania Radiological Accident in Brazil, 1987, is used as a reference for decision-making. Several teams with technical experts should act in an event with RDD, but the medical staffs who respond quickly to the event must be properly protected from the harmful effects of radiation. Based on the radiological protection experts performance during the Goiania accident and the knowledge from lessons learned of many radiological accidents worldwide, this work presents an adaptation of the radiation protection actions for an event with RDD that helps a medical team as primary responders. The following aspects are presented: the problem of radioactive contamination from the explosion of the device in underground environment, the actions of the first responders and evaluation of health radiation effects. This work was based on specialized articles and papers about radiological accidents and RDD; as well as personal communication and academic information of the Institute of Radiation Protection and Dosimetry. The radiation protection actions, adapted to a terrorist attack event with RDD, have as a scenario a subway station in the capital. The main results are: the use of the basic radiation protection principle of time because there is no condition to take care of a patient keeping distance or using a shielding; the use of full appropriate protection cloths for contaminating materials ensuring the physical safety of professionals, and the medical team monitoring at the end of a medical procedure, checking for surface contamination. The main conclusion is that all medical actions

  1. Radiation safety in educational, medical and research institutions. Regulatory guide G-121

    International Nuclear Information System (INIS)

    2000-05-01

    This regulatory guide is intended to help educational, medical and research institutions design and implement radiation protection programs that meed regulatory requirements. This guide applied to educational, medical or research institutions that require a licence from the CNSC to posses or use radioactive materials. It describes programs to assure that radioactive materials are used safely during licensed activities. (author)

  2. Radiation effects on microelectronics in space

    International Nuclear Information System (INIS)

    Srour, J.R.; McGarrity, J.M.

    1988-01-01

    The basic mechanisms of space radiation effects on microelectronics are reviewed in this paper. Topics discussed include the effects of displacement damage and ionizing radiation on devices and circuits, single event phenomena, dose enhancement, radiation effects on optoelectronic devices and passive components, hardening approaches, and simulation of the space radiation environment. A summary is presented of damage mechanisms that can cause temporary or permanent failure of devices and circuits operating in space

  3. Biological in situ Dose Painting for Image-Guided Radiation Therapy Using Drug-Loaded Implantable Devices

    International Nuclear Information System (INIS)

    Cormack, Robert A.; Sridhar, Srinivas; Suh, W. Warren; D'Amico, Anthony V.; Makrigiorgos, G. Mike

    2010-01-01

    Purpose: Implantable devices routinely used for increasing spatial accuracy in modern image-guided radiation treatments (IGRT), such as fiducials or brachytherapy spacers, encompass the potential for in situ release of biologically active drugs, providing an opportunity to enhance the therapeutic ratio. We model this new approach for two types of treatment. Methods and Materials: Radiopaque fiducials used in IGRT, or prostate brachytherapy spacers ('eluters'), were assumed to be loaded with radiosensitizer for in situ drug slow release. An analytic function describing the concentration of radiosensitizer versus distance from eluters, depending on diffusion-elimination properties of the drug in tissue, was developed. Tumor coverage by the drug was modeled for tumors typical of lung stereotactic body radiation therapy treatments for various eluter dimensions and drug properties. Six prostate 125 I brachytherapy cases were analyzed by assuming implantation of drug-loaded spacers. Radiosensitizer-induced subvolume boost was simulated from which biologically effective doses for typical radiosensitizers were calculated in one example. Results: Drug distributions from three-dimensional arrangements of drug eluters versus eluter size and drug properties were tabulated. Four radiosensitizer-loaded fiducials provide adequate radiosensitization for ∼4-cm-diameter lung tumors, thus potentially boosting biologically equivalent doses in centrally located stereotactic body treated lesions. Similarly, multiple drug-loaded spacers provide prostate brachytherapy with flexible shaping of 'biologically equivalent doses' to fit requirements difficult to meet by using radiation alone, e.g., boosting a high-risk region juxtaposed to the urethra while respecting normal tissue tolerance of both the urethra and the rectum. Conclusions: Drug loading of implantable devices routinely used in IGRT provides new opportunities for therapy modulation via biological in situ dose painting.

  4. Insertion devices at the advanced photon source

    International Nuclear Information System (INIS)

    Moog, E.R.

    1996-01-01

    The insertion devices being installed at the Advanced Photon Source cause the stored particle beam to wiggle, emitting x-rays with each wiggle. These x-rays combine to make an intense beam of radiation. Both wiggler and undulator types of insertion devices are being installed; the characteristics of the radiation produced by these two types of insertion devices are discussed, along with the reasons for those characteristics

  5. Standard practice for application of thermoluminescence-dosimetry (TLD) systems for determining absorbed dose in radiation-hardness testing of electronic devices. ASTM standard

    International Nuclear Information System (INIS)

    1998-05-01

    This practice is under the jurisdiction of ASTM Committee E-10 on Nuclear Technology and Applications and is the direct responsibility of Subcommittee E10.07 on Radiation Dosimetry for Radiation Effects on Materials and Devices. Current edition approved Jun. 10, 1997. Published May 1998. Originally published as E 668-78. Last previous edition E 668-93

  6. Monitoring of radiation exposure. Annual report 2000

    International Nuclear Information System (INIS)

    Rantanen, E.

    2001-03-01

    At the end of 2000, there were 1,779 valid safety licenses in Finland for the use of radiation. In addition, there were 2,038 responsible parties for dental x-ray diagnostics. The registry Radiation and Nuclear Safety Authority (STUK) listed 13,754 radiation sources and 270 radionuclide laboratories. In the year 2000 360 inspections were made concerning the safety licences and 53 concerning dental x-ray diagnostics. The import of radioactive substances amounted to 175,836 GBq and export to 74,420 GBq. Short-lived radionuclides produced in Finland amounted to 55,527 GBq. In the year 2000 there were 10,846 workers monitored for radiation exposure at 1,171 work sites. Of these employees, 27% received an annual dose exceeding the recording level. The annual effective dose limit was not exceeded. The total dose recorded in the dose registry(sum of the individual dosemeter readings) was 6.5 Sv in 2000

  7. Review of the first partial licence for the Muelheim-Kaerlich reactor on the basis of the licensing requirements under nuclear law

    International Nuclear Information System (INIS)

    Hahn, L.; Wimmer, J.

    1990-11-01

    The expert opinion is restricted in the main to the licensing requirements in connection with the latest state-of-the-art precautionary measures against damage, i.e. subsection 3 of paragraph 7 section 2 Atomic Energy Act. Subject of the evaluations regarding the required new scope of licensing were the cancelled first partial licence, subsequent partial licences, the TUEV (Technical Control Board) expert opinion, the safety report with its continuations as well as the judgments of the Higher Administrative Court in Koblenz and the Federal Administrative Court. For determining the state-of-the-art, the expert opinion refers to the valid body of regulations, the latest concepts for PWRs in particular in the Federal Republic of Germany, and more recent results in reactor safety research. (orig./DG) [de

  8. Design and implementation of a device for measuring radiation energy of an electron accelerator

    International Nuclear Information System (INIS)

    Salhi, Heythem; Selmi, Samir

    2010-01-01

    Our work is part of a graduation project at the School of Technology and Computing, to obtain a master's degree in electrical engineering specialty industrial computer. Throughout the four-month internship at the National Center for Nuclear Science and Technology (CNSTN), we have learned to practice the knowledge acquired during the formative years and to manage our working time. Our job was to design and implementation of a device for measuring the energy of radiation. Our project meets the needs of users in the radio treatment Unit, which amount to automate measurement of radiation energy from the electron accelerator. This project has been beneficial on several levels: it was an opportunity to achieve better control of printed circuits, especially when they are dual layer and learning a new programming language that is actually BASIC. In human terms, this work has given us the opportunity to learn to manage our time, and learn teamwork. However, we are convinced that this project can be enhanced on various levels. It can be considered as a starting point of a contribution to the real-time measurement of the energy of radiation.

  9. Safety considerations in the design of the Fusion Engineering Device

    International Nuclear Information System (INIS)

    Barrett, R.J.

    1983-01-01

    The US Department of Energy (DOE) regulations and guidelines for radiation protection have been reviewed and are being applied to the device design. Direct radiation protection is provided by the device shield and the reactor building walls. Radiation from the activated device components and the tritium fuel is to be controlled with shielding, contamination control, and ventilation. The potential release of tritium from the plant has influenced the selection of reactor building and plant designs and specifications. The safety of the plant workers is affected primarily by the radiation from the activated device components and from plasma chamber debris

  10. Over-the-air Radiated Testing of Millimeter-Wave Beam-steerable Devices in a Cost-Effective Measurement Setup

    DEFF Research Database (Denmark)

    Fan, Wei; Kyösti, Pekka; Rumney, Moray

    2018-01-01

    antenna selection scheme is proposed. This setup is suitable for evaluation of beam-steerable devices, including both base station (BS) and user equipment (UE) devices. The requirements for the test system design are analyzed, including the measurement range, number of OTA antennas, number of active OTA...... conditions. In this article, radiated testing methods are reviewed, with a focus on their principle and applicability for beam steerable mmWave devices. To explore the spatial sparsity of mmWave channel profiles, a cost-effective simplified 3D sectored multi-probe anechoic chamber (MPAC) system with an OTA......With the severe spectrum congestion of sub-6GHz cellular systems, large-scale antenna systems in the millimeter-wave (mmWave) bands can potentially meet the high data rate envisioned for fifth generation (5G) communications. Performance evaluation of antenna systems is an essential step...

  11. A device for external γ-irradiation of experimental animals

    International Nuclear Information System (INIS)

    Ivanitskaya, N.F.; Talakin, Yu.N.; Lekakh, V.A.

    1992-01-01

    A device was developed for external gamma-irradiation of experimental animals including a radiation source, a device for fixation of the total animal or a segment of its body in the focus of irradiation, and a shilding screen. To widen the sphere of this device application by making possible a simultaneous radiation exposure of a group of animals under various radiation schedules, the device involves two discs with a common axis. The lower disc is provided with an electric drive and containers with animals are placed on it, and the upper disc is for the shielding screen. The device is supplied with an operation block

  12. Principles and techniques of radiation hardening. Volume 2. Transient radiation effects in electronics (TREE)

    International Nuclear Information System (INIS)

    Rudie, N.J.

    1976-01-01

    The three-volume book is intended to serve as a review of the effects of thermonuclear explosion induced radiation (x-rays, gamma rays, and beta particles) and the resulting electromagnetic pulse (EMP). Volume 2 deals with the following topics: radiation effects on quartz crystals, tantalum capacitors, bipolar semiconductor devices and integrated circuits, field effect transistors, and miscellaneous electronic devices; hardening electronic systems to photon and neutron radiation; nuclear radiation source and/or effects simulation techniques; and radiation dosimetry

  13. Calculation of characteristics of X-ray devices

    Directory of Open Access Journals (Sweden)

    Orobinskyi A. N.

    2015-12-01

    Full Text Available Actuality of this work is related to human radiation safety during tuning and regulation of X-ray devices in the process of their development and production. The more precise the calculations for the device are, the less time is required for its tuning and regulation, and thus people are less exposed to radiation. When developing an X-ray device, it is necessary to choose an X-ray tube and filters taking into account the application domain of the device. In order to do this, one should know anode voltage, X-ray tube anode current, material and thickness of filters, i.e. to calculate these characteristics at the set quality of X-ray radiation. The known published studies do not give any solution to this problem. The scientific novelty of this work is that it establishes the interdependence between main characteristics of the X-ray device: the function of the device defines the quality of X-ray radiation (mean photon energy and air kerma power; mean photon energy depends on the X-ray anode tube voltage and spectral resolution; air kerma power depends on anode tube voltage, current of X-ray tube anode, spectral resolution, thicknesses of the filters and their materials; spectral resolution depends on thicknesses of filters and their materials; thickness of filters depends on the material of the filter (the linear coefficient of weakening of X-ray radiation. Knowledge of interdependence of basic characteristics of the X-ray devices allowes developing simple algorithm for their calculation at the values of homogeneity coefficient from 0,8 to 1, which makes it possible to choose an X-ray tube and filters with the purpose of obtaining X-ray radiation of the set quality.

  14. Nuclear fuel shipping inspection device

    International Nuclear Information System (INIS)

    Takahashi, Toshio; Hada, Koji.

    1988-01-01

    Purpose: To provide an nuclear fuel shipping inspection device having a high detection sensitivity and capable of obtaining highly reliable inspection results. Constitution: The present invention concerns a device for distinguishing a fuel assembly having failed fuel rods in LMFBR type reactors. Coolants in a fuel assembly to be inspected are collected by a sampling pipeway and transferred to a filter device. In the filter device, granular radioactive corrosion products (CP) in the coolants are captured, to reduce the background. The coolants, after being passed through the filter device, are transferred to an FP catching device and gamma-rays of iodine and cesium nuclides are measured in FP radiation measuring device. Subsequently, the coolants transferred to a degasing device to separate rare gas FP in the coolants from the liquid phase. In a case if rare gas fission products are detected by the radiation detector, it means that there is a failed fuel rod in the fuel assembly to be inspected. Since the CP and the soluble FP are separated and extracted for the radioactivity measurement, the reliability can be improved. (Kamimura, M.)

  15. Use of radiation and radiation practices in 1993. Events and statistics

    International Nuclear Information System (INIS)

    Havukainen, R.

    1994-05-01

    In the end of the year 1993 there were in force 1740 safety licences for the use of radiation granted by the Finnish Centre for Radiation and Nuclear Safety (STUK). In addition to this there were 2100 places for dental x-ray activities in Finland. All together 12726 radiation sources and 313 radioisotope laboratories were in use. The import of radioactive substances was 3.9 x 10 15 Bq and the export 2.5 x 10 13 Bq. The production of short-lived isotopes was 1.3 x 10 13 Bq. The monitoring of personal radiation doses was organized for 11171 workers and 1299 working places. The annual dose (the integrated readings of dosemeters) was greater than registration threshold for 24% of workers. The collective dose (the sum of the results of the dose measurements) registered to the Finnish Dose Register was 6.9 manSv; 74% belonged to the workers of nuclear power plants. The sum of the personal doses measured in 1993 were for three interventional radiologists and fifteen workers in nuclear power plants 20 mSv or more. The effective doses were in each case under the annual dose limit of 50 mSv. The effective doses for the interventional radiologists were under 20 mSv. (7 figs., 16 tabs.)

  16. Evaluation of the Stryker S2 IM Nail Distal Targeting Device for reduction of radiation exposure: a case series study.

    Science.gov (United States)

    Anastopoulos, George; Ntagiopoulos, Panagiotis G; Chissas, Dionisios; Loupasis, George; Asimakopoulos, Antonios; Athanaselis, Eustratios; Megas, Panagiotis

    2008-10-01

    Distal locking is one challenging step during intramedullary nailing of femoral shaft fractures that can lead to an increase of radiation exposure. In the present study, the authors describe a technique for the distal locking of femoral nails, implementing a new targeting device in an attempt to reduce radiation exposure and operational time. Over a 2-year period, 127 consecutive cases of femoral shaft fractures were included in the study. All cases were treated with nailing of femoral shaft fractures with an unslotted reamed antegrade femoral nail and distal locking was performed with the use of a proximally mounted aiming device. Mean duration of the procedure was 63.5 18.1 min while the duration for distal locking was 6.6 +/- 2.6 min. In all successful cases, exposure from intraoperative fluoroscopy was 17.2 +/- 7.4 s for the whole operative procedure, and for distal locking was 2 shots, 1.35 s (range, 0.9-2.2 s) and 1.9 mGy (range, 1.1-2.9 mGy). Five cases (3.9%) were unsuccessful, but overall no intraoperative complications were encountered from the application of this technique. The ability of the device to correspond to the level of nail deformation and to properly identify the distal holes, reduced exposure to radiation compared to other published reports, and should be considered as a valuable tool for distal locking of femoral fractures.

  17. Suppliers' activities within the controlled zones of licensees handling ionizing radiation sources. Recommendations

    International Nuclear Information System (INIS)

    1999-01-01

    The Recommendations are intended to lay down a unified procedure for preparing licence applications related to ionizing radiation source handling, including the required documentation. The guidelines were set up based on documents of the Dukovany nuclear power plant and adapted to serve the Temelin nuclear power plant and other workplaces handling ionizing radiation sources as well. Selected provisions of applicable legislation are reproduced, and responsibilities are described. The major part of the publication is constituted by model documents, particularly a model Quality Assurance Programme. (P.A.)

  18. X ray sensitive area detection device

    Science.gov (United States)

    Carter, Daniel C. (Inventor); Witherow, William K. (Inventor); Pusey, Marc L. (Inventor); Yost, Vaughn H. (Inventor)

    1990-01-01

    A radiation sensitive area detection device is disclosed which comprises a phosphor-containing film capable of receiving and storing an image formed by a pattern of incoming x rays, UV, or other radiation falling on the film. The device is capable of fluorescing in response to stimulation by a light source in a manner directly proportional to the stored radiation pattern. The device includes: (1) a light source capable of projecting light or other appropriate electromagnetic wave on the film so as to cause it to fluoresce; (2) a means to focus the fluoresced light coming from the phosphor-containing film after light stimulation; and (3) at least one charged coupled detector or other detecting element capable of receiving and digitizing the pattern of fluoresced light coming from the phosphor-containing film. The device will be able to generate superior x ray images of high resolution from a crystal or other sample and will be particularly advantageous in that instantaneous near-real-time images of rapidly deteriorating samples can be obtained. Furthermore, the device can be made compact and sturdy, thus capable of carrying out x ray or other radiation imaging under a variety of conditions, including those experienced in space.

  19. Amorphous silicon radiation detectors

    Science.gov (United States)

    Street, Robert A.; Perez-Mendez, Victor; Kaplan, Selig N.

    1992-01-01

    Hydrogenated amorphous silicon radiation detector devices having enhanced signal are disclosed. Specifically provided are transversely oriented electrode layers and layered detector configurations of amorphous silicon, the structure of which allow high electric fields upon application of a bias thereby beneficially resulting in a reduction in noise from contact injection and an increase in signal including avalanche multiplication and gain of the signal produced by incoming high energy radiation. These enhanced radiation sensitive devices can be used as measuring and detection means for visible light, low energy photons and high energy ionizing particles such as electrons, x-rays, alpha particles, beta particles and gamma radiation. Particular utility of the device is disclosed for precision powder crystallography and biological identification.

  20. Optimization of paediatric radiation doses with CR systems

    International Nuclear Information System (INIS)

    Zatelli, Giovanna; Mazzocchi, S.; Ciccarone, A.; Fonda, C.; De Otto, G.

    2008-01-01

    Full text: Radiation protection of paediatric patients is a primary objective in paediatric radiology due the higher life expectance of the little patients undergoing radiology examinations and due to the higher radiosensitivity of tissues. Aim of this work is the study of the optimization process in paediatric doses needed after the recent installation of a new Computed Radiography System in the Radiology of the Meyer paediatric Hospital, in Florence, Italy. This process involves both the use of new dedicated digitizer (Agfa DX-S) and elaboration software (Agfa NX2.0). The choice of the DX-S systems has been performed in consideration of high resolution (Scanhead technology - DirectriX detector), image sharpness and portability of the cassettes that make DX-S ideal in paediatric applications as neonatal intensive care. The NX software for image processing has been installed with the 'Paediatric' licence that optimizes paediatric images especially for exposures of premature newborns. Paediatric NX automatically selects the paediatric age group, depending on the patient's birth date. Each age group contains enhanced algorithms and settings adapted to age group, for optimized visibility of fine details. All the CR system has been accepted by mean of quality control acceptance tool AGFA AutoQC2, and all the automatic exposure control devices installed on radiographic devices were previously calibrated in accordance to literature with signal to noise vs dose considerations [S. Mazzocchi et al. 'AEC set-up optimization with computed radiography imaging' Radiat. Prot. Dosim. 117, 169-173 2005]. Paediatric patients were then divided into age-weight categories and the Entrance Surface Doses (ESD) were calculated by output x-rays measurements. ESD for thorax examinations were correlated to the image evaluations performed by experienced radiologists following European Guidelines on quality criteria for diagnostic radiographic images in paediatrics (EUR 16261, European

  1. Characterization of Personal Privacy Devices (PPD) radiation pattern impact on the ground and airborne segments of the local area augmentation system (LAAS) at GPS L1 frequency

    Science.gov (United States)

    Alkhateeb, Abualkair M. Khair

    Personal Privacy Devices (PPDs) are radio-frequency transmitters that intentionally transmit in a frequency band used by other devices for the intent purpose of denying service to those devices. These devices have shown the potential to interfere with the ground and air sub-systems of the Local Area Augmentation Systems (LAAS), a GPS-based navigation aids at commercial airports. The Federal Aviation Administration (FAA) is concerned by the potential impact of these devices to GPS navigation aids at airports and has commenced an activity to determine the severity of this threat. In support of this situation, the research in this dissertation has been conducted under (FAA) Cooperative Agreement 2011-G-012, to investigate the impact of these devices on the LAAS. In order to investigate the impact of PPDs Radio Frequency Interference (RFI) on the ground and air sub-systems of the LAAS, the work presented in phase one of this research is intended to characterize the vehicle's impact on the PPD's Effective Isotropic Radiated Power (EIRP). A study was conceived in this research to characterize PPD performance by examining the on-vehicle radiation patterns as a function of vehicle type, jammer type, jammer location inside a vehicle and jammer orientation at each location. Phase two was to characterize the GPS Radiation Pattern on Multipath Limiting Antenna. MLA has to meet stringent requirements for acceptable signal detection and multipath rejection. The ARL-2100 is the most recent MLA antenna proposed to be used in the LAAS ground segment. The ground-based antenna's radiation pattern was modeled. This was achieved via (HFSS) a commercial-off the shelf CAD-based modeling code with a full-wave electromagnetic software simulation package that uses the Finite Element Analysis. Phase three of this work has been conducted to study the characteristics of the GPS Radiation Pattern on Commercial Aircraft. The airborne GPS antenna was modeled and the resulting radiation pattern on

  2. Radiation effects on and dose enhancement of electronic materials

    International Nuclear Information System (INIS)

    Srour, J.R.; Long, D.M.

    1984-01-01

    This book describes radiation effects on and dose enhancement factors for electronic materials. Alteration of the electrical properties of solid-state devices and integrated circuits by impinging radiation is well-known. Such changes may cause an electronic subsystem to fail, thus there is currently great interest in devising methods for avoiding radiation-induced degradation. The development of radiation-hardened devices and circuits is an exciting approach to solving this problem for many applications, since it could minimize the need for shielding or other system hardening techniques. Part 1 describes the basic mechanisms of radiation effects on electronic materials, devices, and integrated circuits. Radiation effects in bulk silicon and in silicon devices are treated. Ionizing radiation effects in silicon dioxide films and silicon MOS devices are discussed. Single event phenomena are considered. Key literature references and a bibliography are provided. Part II provides tabulations of dose enhancement factors for electronic devices in x-ray and gamma-ray environments. The data are applicable to a wide range of semiconductor devices and selected types of capacitors. Radiation environments discussed find application in system design and in radiation test facilities

  3. The exemption from the requirement of registration and/or licensing of some sources. machines and devices emitting ionizing and /or on ionizing radiation: a proposed draft for Israeli regulations

    Energy Technology Data Exchange (ETDEWEB)

    Schlesinger, T; Margaliot, M [Israel Atomic Energy Commission, Yavne (Israel). Soreq Nuclear Research Center

    1997-11-16

    The licensing and authorization of the import, purchase, distribution, transportation and application of radioactive materials and devices emitting ionizing and/or non-ionizing radiation are carried out in Israel by the Ministries of the Environment and of Health. The legal basis for file authority of these Ministries in radiation protection matters is file {sup P}harmacists Regulation- Radioactive Elements and Products Thereof, 1981 (revision 1994) (PRREPT). Licenses are issued by the Chief Radiation Executive (CUE) appointed by the Minister of the Environment and the Minister of Health. The Regulations include a clause which enables the CUE to exempt certain amounts of radioactive materials from file requirements laid down in the PRREPT. The exemption clause is general and does not indicate the types and amounts of radioactive material may be exempted. The proposed draft Israeli regulations are related to exemption of some sources, machines and devices emitting ionizing and non-ionizing radiation, wife a suggestion to extend file above mentioned exemption clause to include some machines and devices and to provide an explicit and detailed list of materials, sources and devices to be exempted. Among these are the following: (authors)

  4. The exemption from the requirement of registration and/or licensing of some sources. machines and devices emitting ionizing and /or on ionizing radiation: a proposed draft for Israeli regulations

    International Nuclear Information System (INIS)

    Schlesinger, T.; Margaliot, M.

    1997-01-01

    The licensing and authorization of the import, purchase, distribution, transportation and application of radioactive materials and devices emitting ionizing and/or non-ionizing radiation are carried out in Israel by the Ministries of the Environment and of Health. The legal basis for file authority of these Ministries in radiation protection matters is file P harmacists Regulation- Radioactive Elements and Products Thereof, 1981 (revision 1994) (PRREPT). Licenses are issued by the Chief Radiation Executive (CUE) appointed by the Minister of the Environment and the Minister of Health. The Regulations include a clause which enables the CUE to exempt certain amounts of radioactive materials from file requirements laid down in the PRREPT. The exemption clause is general and does not indicate the types and amounts of radioactive material may be exempted. The proposed draft Israeli regulations are related to exemption of some sources, machines and devices emitting ionizing and non-ionizing radiation, wife a suggestion to extend file above mentioned exemption clause to include some machines and devices and to provide an explicit and detailed list of materials, sources and devices to be exempted. Among these are the following: (authors)

  5. Real-time and on-site γ-ray radiation response testing system for semiconductor devices and its applications

    Energy Technology Data Exchange (ETDEWEB)

    Mu, Yifei, E-mail: Y.Mu@student.liverpool.ac.uk [Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool L69 3GJ (United Kingdom); Zhao, Ce Zhou, E-mail: cezhou.zhao@xjtlu.edu.cn [Department of Electrical and Electronic Engineering, Xi’an Jiaotong-Liverpool University, Suzhou 215123 (China); Qi, Yanfei, E-mail: yanfei.qi01@xjtlu.edu.cn [Department of Electrical and Electronic Engineering, Xi’an Jiaotong-Liverpool University, Suzhou 215123 (China); Lam, Sang, E-mail: s.lam@xjtlu.edu.cn [Department of Electrical and Electronic Engineering, Xi’an Jiaotong-Liverpool University, Suzhou 215123 (China); Zhao, Chun, E-mail: garyzhao@ust.hk [Nano and Advanced Materials Institute, Hong Kong University of Science and Technology, Kowloon (Hong Kong); Lu, Qifeng, E-mail: qifeng@liverpool.ac.uk [Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool L69 3GJ (United Kingdom); Cai, Yutao, E-mail: yutao.cai@xjtlu.edu.cn [Department of Electrical and Electronic Engineering, Xi’an Jiaotong-Liverpool University, Suzhou 215123 (China); Mitrovic, Ivona Z., E-mail: ivona@liverpool.ac.uk [Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool L69 3GJ (United Kingdom); Taylor, Stephen, E-mail: s.taylor@liverpool.ac.uk [Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool L69 3GJ (United Kingdom); Chalker, Paul R., E-mail: pchalker@liverpool.ac.uk [Center for Materials and Structures, School of Engineering, University of Liverpool, Liverpool L69 3GH (United Kingdom)

    2016-04-01

    The construction of a turnkey real-time and on-site radiation response testing system for semiconductor devices is reported. Components of an on-site radiation response probe station, which contains a 1.11 GBq Cs{sup 137} gamma (γ)-ray source, and equipment of a real-time measurement system are described in detail for the construction of the whole system. The real-time measurement system includes a conventional capacitance–voltage (C–V) and stress module, a pulse C–V and stress module, a conventional current–voltage (I–V) and stress module, a pulse I–V and stress module, a DC on-the-fly (OTF) module and a pulse OTF module. Electrical characteristics of MOS capacitors or MOSFET devices are measured by each module integrated in the probe station under continuous γ-ray exposure and the measurement results are presented. The dose rates of different gate dielectrics are calculated by a novel calculation model based on the Cs{sup 137} γ-ray source placed in the probe station. For the sake of operators’ safety, an equivalent dose rate of 70 nSv/h at a given operation distance is indicated by a dose attenuation model in the experimental environment. HfO{sub 2} thin films formed by atomic layer deposition are employed to investigate the radiation response of the high-κ material by using the conventional C–V and pulse C–V modules. The irradiation exposure of the sample is carried out with a dose rate of 0.175 rad/s and ±1 V bias in the radiation response testing system. Analysis of flat-band voltage shifts (ΔV{sub FB}) of the MOS capacitors suggests that the on-site and real-time/pulse measurements detect more serious degradation of the HfO{sub 2} thin films compared with the off-site irradiation and conventional measurement techniques.

  6. Radiation effects modeling and experimental data on I2L devices

    International Nuclear Information System (INIS)

    Long, D.M.; Repper, C.J.; Ragonese, L.J.; Yang, N.T.

    1976-01-01

    This paper reports on an Integrated Injection Logic (I 2 L) radiation effects model which includes radiation effects phenomena. Twenty-five individual current components were identified for an I 2 L logic gate by assuming wholly vertical or wholly horizontal current flow. Equations were developed for each component in terms of basic parameters such as doping profiles, distances, and diffusion lengths, and set up on a computer for specific logic cell configurations. For neutron damage, the model shows excellent agreement with experimental data. Reactor test results on GE I 2 L samples showed a neutron hardness level in the range of 6 x 10 12 to 3 x 10 13 n/cm 2 (1 MeV Eq), and cobalt-60 tests showed a total dose hardness of 6 x 10 4 to greater than 1 x 10 6 Rads(Si) (all device types at an injection current of 50 microamps per gate). It was found that significant hardness improvements could be achieved by: (a) diffusion profile variation, (b) utilizing a tight N + collar around the cell, and (c) locating the collector close to the injector. Flash X-ray tests showed a transient logic upset threshold of 1 x 10 9 Rads(Si)/sec for a 28 ns pulse, and a survival level greater than 2 x 10 12 Rads(Si)/sec

  7. Workplace photon radiation fields

    International Nuclear Information System (INIS)

    Burgess, P.H.; Bartlett, D.T.; Ambrosi, P.

    1999-01-01

    The knowledge of workplace radiation fields is essential for measures in radiation protection. Information about the energy and directional distribution of the incident photon radiation was obtained by several devices developed by the National Radiation Protection Board, United Kingdom, by the Statens Stralskyddsinstitut, Sweden, together with EURADOS and by the Physikalisch-Technische Bundesanstalt, Germany. The devices are described and some results obtained at workplaces in nuclear industry, medicine and science in the photon energy range from 20 keV to 7 MeV are given. (author)

  8. Method and means of reducing erosion of components of plasma devices exposed to helium and hydrogen isotope radiation

    International Nuclear Information System (INIS)

    Kaminsky, M.S.; Das, S.K.; Rossing, T.D.

    1977-01-01

    Surfaces of components of plasma devices exposed to radiation by atoms or ions of helium or isotopes of hydrogen can be protected from damage due to blistering by shielding the surfaces with a structure formed by sintering a powder of aluminum or beryllium and its oxide or by coating the surfaces with such a sintered metal powder. 7 claims

  9. The 16 MeV - microtron at the Institute for Physics and Technology of Radiation Devices and its application

    International Nuclear Information System (INIS)

    Catana, D.; Panaitescu, I.; Axinescu, S.; Minea, R.

    1992-01-01

    The 17-orbit microtron at the Institute for Physics and Technology of Radiation Devices, Bucharest is described. The energy of electrons is 11 MeV in the first accelerating mode and 16 MeV in the second accelerating mode with a pulse beam power of about 400 Kw and a duty ratio of 10 -3 . (Author)

  10. Directive of the Minister of Public Health and Environmental Protection of 14 October 1975, Stcrt. 203 in implementation of Section 28 of the Nuclear Energy Act (Devices) Decree

    International Nuclear Information System (INIS)

    1975-01-01

    This Directive lays down the procedure for applications for licences under the Devices Decree. The competent authority in this respect is the Minister of Public Health and Environmental Protection, formerly the State Secretary for Social Affairs and Public Health. (NEA) [fr

  11. Study of total ionization dose effects in electronic devices

    International Nuclear Information System (INIS)

    Nidhin, T.S.; Bhattacharyya, Anindya; Gour, Aditya; Behera, R.P.; Jayanthi, T.

    2018-01-01

    Radiation effects in electronic devices are a major challenge in the dependable application developments of nuclear power plant instrumentation and control systems. The main radiation effects are total ionization dose (TID) effects, displacement damage dose (DDD) effects and single event effects (SEE). In this study, we are concentrating on TID effects in electronic devices. The focus of the study is mainly on SRAM based field programmable gate arrays (FPGA) along with that the devices of our interest are voltage regulators, flash memory and optocoupler. The experiments are conducted by exposing the devices to gamma radiation in power off condition and the degradation in the performances are analysed

  12. Promoting Active Transport in Older Adolescents Before They Obtain Their Driving Licence: A Matched Control Intervention Study.

    Science.gov (United States)

    Verhoeven, Hannah; Simons, Dorien; Van Cauwenberg, Jelle; Van Dyck, Delfien; Vandelanotte, Corneel; de Geus, Bas; De Bourdeaudhuij, Ilse; Clarys, Peter; Deforche, Benedicte

    2016-01-01

    Active transport has great potential to increase physical activity in older adolescents (17-18 years). Therefore, a theory- and evidence-based intervention was developed aiming to promote active transport among older adolescents. The intervention aimed to influence psychosocial factors of active transport since this is the first step in order to achieve a change in behaviour. The present study aimed to examine the effect of the intervention on the following psychosocial factors: intention to use active transport after obtaining a driving licence, perceived benefits, perceived barriers, subjective norm, self-efficacy, habit and awareness towards active transport. A matched control three-arm study was conducted and consisted of a pre-test post-test design with intervention and control schools in Flanders (northern part of Belgium). A lesson promoting active transport was implemented as the last lesson in the course 'Driving Licence at School' in intervention schools (intervention group 1). Individuals in intervention group 2 received this active transport lesson and, in addition, they were asked to become a member of a Facebook group on active transport. Individuals in the control group only attended the regular course 'Driving Licence at School'. Participants completed a questionnaire assessing socio-demographics and psychosocial variables at baseline, post (after one week) and follow-up (after eight weeks). To assess intervention effects, multilevel linear mixed models analyses were performed. A sample of 441 older adolescents (56.8% female; 17.4 (0.7) years) was analysed. For awareness regarding the existence of car sharing schemes, a significant increase in awareness from baseline to post measurement was found within intervention group 1 (p = 0.001) and intervention group 2 (p = 0.030) compared to the control group in which no change was found. In addition, a significant increase in awareness from baseline to follow-up measurement was found within intervention

  13. Promoting Active Transport in Older Adolescents Before They Obtain Their Driving Licence: A Matched Control Intervention Study.

    Directory of Open Access Journals (Sweden)

    Hannah Verhoeven

    Full Text Available Active transport has great potential to increase physical activity in older adolescents (17-18 years. Therefore, a theory- and evidence-based intervention was developed aiming to promote active transport among older adolescents. The intervention aimed to influence psychosocial factors of active transport since this is the first step in order to achieve a change in behaviour. The present study aimed to examine the effect of the intervention on the following psychosocial factors: intention to use active transport after obtaining a driving licence, perceived benefits, perceived barriers, subjective norm, self-efficacy, habit and awareness towards active transport.A matched control three-arm study was conducted and consisted of a pre-test post-test design with intervention and control schools in Flanders (northern part of Belgium. A lesson promoting active transport was implemented as the last lesson in the course 'Driving Licence at School' in intervention schools (intervention group 1. Individuals in intervention group 2 received this active transport lesson and, in addition, they were asked to become a member of a Facebook group on active transport. Individuals in the control group only attended the regular course 'Driving Licence at School'. Participants completed a questionnaire assessing socio-demographics and psychosocial variables at baseline, post (after one week and follow-up (after eight weeks. To assess intervention effects, multilevel linear mixed models analyses were performed.A sample of 441 older adolescents (56.8% female; 17.4 (0.7 years was analysed. For awareness regarding the existence of car sharing schemes, a significant increase in awareness from baseline to post measurement was found within intervention group 1 (p = 0.001 and intervention group 2 (p = 0.030 compared to the control group in which no change was found. In addition, a significant increase in awareness from baseline to follow-up measurement was found within

  14. 76 FR 34845 - Medical Devices; Ear, Nose, and Throat Devices; Classification of the Wireless Air-Conduction...

    Science.gov (United States)

    2011-06-15

    ... control by other users with a similar medical device. Exposure to non-ionizing radiation Wireless... relating to EMC and wireless technology and human exposure to non-ionizing radiation. Therefore, on March... electro magnetic compatibility (EMC) and safety of exposure to non-ionizing radiation; (2) Design...

  15. Theoretical study of the thermal radiation of rough surfaces. Development of a device for the measurement of emissivity, and application to AISI 316 stainless steel

    International Nuclear Information System (INIS)

    Heinisch, Bruno

    1982-01-01

    Within the frame of the study of heat transfers by radiation, this research thesis addresses the theoretical and experimental determination of the directional monochromatic emissivity. After some theoretical recalls, the author presents models for a direct calculation of emissivity, which in fact calculate bidirectional reflectivity by using laws of physical optics. An experimental device has been developed for the direct measurement of directional monochromatic emissivity of materials in the infrared (wavelength from 2 to 15 microns) in a polarised radiation. This device uses double beam with double modulation. Experimental results are presented for the 316 stainless steel [fr

  16. Deposition of tellurium films by decomposition of electrochemically-generated H{sub 2}Te: application to radiative cooling devices

    Energy Technology Data Exchange (ETDEWEB)

    Engelhard, T.; Jones, E.D.; Viney, I. [Coventry Univ. (United Kingdom). Centre for Data Storage Mater.; Mastai, Y.; Hodes, G. [Department of Materials and Interfaces, Weizmann Institute of Science, 76100, Rehovot (Israel)

    2000-07-17

    The preparation of homogenous, large area thin layers of tellurium on thin polyethylene foils is described. The tellurium was formed by room temperature decomposition of electrochemically generated H{sub 2}Te. Pre-treatment of the polyethylene substrates with KMnO{sub 4} to give a Mn-oxide layer was found to improve the Te adhesion and homogeneity. Optical characterization of the layers was performed using UV/VIS/NIR spectroscopy. Such coatings have favorable characteristics for use as solar radiation shields in radiative cooling devices. The simplicity of generation of the very unstable H{sub 2}Te was also exploited to demonstrate formation of size-quantized CdTe nanocrystals. (orig.)

  17. Monte Carlo generator ELRADGEN 2.0 for simulation of radiative events in elastic ep-scattering of polarized particles

    Science.gov (United States)

    Akushevich, I.; Filoti, O. F.; Ilyichev, A.; Shumeiko, N.

    2012-07-01

    The structure and algorithms of the Monte Carlo generator ELRADGEN 2.0 designed to simulate radiative events in polarized ep-scattering are presented. The full set of analytical expressions for the QED radiative corrections is presented and discussed in detail. Algorithmic improvements implemented to provide faster simulation of hard real photon events are described. Numerical tests show high quality of generation of photonic variables and radiatively corrected cross section. The comparison of the elastic radiative tail simulated within the kinematical conditions of the BLAST experiment at MIT BATES shows a good agreement with experimental data. Catalogue identifier: AELO_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AELO_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC license, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 1299 No. of bytes in distributed program, including test data, etc.: 11 348 Distribution format: tar.gz Programming language: FORTRAN 77 Computer: All Operating system: Any RAM: 1 MB Classification: 11.2, 11.4 Nature of problem: Simulation of radiative events in polarized ep-scattering. Solution method: Monte Carlo simulation according to the distributions of the real photon kinematic variables that are calculated by the covariant method of QED radiative correction estimation. The approach provides rather fast and accurate generation. Running time: The simulation of 108 radiative events for itest:=1 takes up to 52 seconds on Pentium(R) Dual-Core 2.00 GHz processor.

  18. Safety considerations in the design of the fusion engineering device

    International Nuclear Information System (INIS)

    Barrett, R.J.

    1983-01-01

    Safety considerations play a significant role in the design of a near-term Fusion Engineering Device (FED). For the safety of the general public and the plant workers, the radiation environment caused by the reacting plasma and the potential release of tritium fuel are the dominant considerations. The U.S. Department of Energy (DOE) regulations and guidelines for radiation protection have been reviewed and are being applied to the device design. Direct radiation protection is provided by the device shield and the reactor building walls. Radiation from the activated device components and the tritium fuel is to be controlled with shielding, contamination control, and ventilation. The potential release of tritium from the plant has influenced the selection of reactor building and plant designs and specifications. The safety of the plant workers is affected primarily by the radiation from the activated device components and from plasma chamber debris. The highly activated device components make it necessary to design many of the maintenance activities in the reactor building for totally remote operation. The hot cell facility has evolved as a totally remote maintenance facility due to the high radiation levels of the device components. Safety considerations have had substantial impacts on the design of FED. Several examples of safety-related design impacts are discussed in the paper. Feasible solutions have been identified for all outstanding safety-related items, and additional optimization of these solutions is anticipated in future design studies

  19. On Radiated Performance Evaluation of Massive MIMO Devices in Multi-Probe Anechoic Chamber OTA Setups

    DEFF Research Database (Denmark)

    Kyösti, Pekka; Hentilä, Lassi; Fan, Wei

    2018-01-01

    Radiated testing of massive multiple-input-multipleoutput (MIMO) devices in fading radio channel conditions is expected to be essential in development of the fifth generation (5G) base stations (BS) and user equipment (UE) operating at or close to the millimetre wave (mm-wave) frequencies. In thi...... setup and find key design parameters by simulations. The results with the utilized channel models indicate that at 28 GHz up to 1616 planar arrays can be tested with range length of one meter and with at minimum eight active dual polarized probes....

  20. Use of radiation and radiation practices in 1993. Events and statistics

    Energy Technology Data Exchange (ETDEWEB)

    Havukainen, R [ed.

    1994-05-01

    In the end of the year 1993 there were in force 1740 safety licences for the use of radiation granted by the Finnish Centre for Radiation and Nuclear Safety (STUK). In addition to this there were 2100 places for dental x-ray activities in Finland. All together 12726 radiation sources and 313 radioisotope laboratories were in use. The import of radioactive substances was 3.9 x 10 {sup 15} Bq and the export 2.5 x 10 {sup 13} Bq. The production of short-lived isotopes was 1.3 x 10 {sup 13} Bq. The monitoring of personal radiation doses was organized for 11171 workers and 1299 working places. The annual dose (the integrated readings of dosemeters) was greater than registration threshold for 24% of workers. The collective dose (the sum of the results of the dose measurements) registered to the Finnish Dose Register was 6.9 manSv; 74% belonged to the workers of nuclear power plants. The sum of the personal doses measured in 1993 were for three interventional radiologists and fifteen workers in nuclear power plants 20 mSv or more. The effective doses were in each case under the annual dose limit of 50 mSv. The effective doses for the interventional radiologists were under 20 mSv. (7 figs., 16 tabs.).

  1. Comparative Study on Radiological Impact Due To Direct Exposure to a Radiological Dispersal Device Using A Sealed Radiation Source

    International Nuclear Information System (INIS)

    Margeanu, C.A.

    2011-01-01

    Nowadays, one of the most serious terrorist threats implies radiological dispersal devices (RDDs), the so-called dirty bombs, that combine a conventional explosive surrounded by an inflammatory material (like thermit) with radioactive material. The paper objective is to evaluate the radiological impact due to direct exposure to a RDD using a sealed radiation source (used for medical and industrial applications) as radioactive material. The simulations were performed for 60Co, 137Cs and 192Ir radiation sources. In order to model the contamination potential level and radiation exposure due to radioactive material spreading from RDD, Lawrence Livermore National Laboratory's HOTSPOT 2.07 computer code was used. The worst case scenario has been considered, calculations being performed for two radioactive material dispersion models, namely General radioactive Plume and General Explosion. Following parameters evolution with distance from the radiation source was investigated: total effective dose equivalent, time-integrated air concentration, ground surface deposition and ground shine dose rates. Comparisons between considered radiation sources and radioactive material dispersion models have been performed. The most drastic effects on population and the environment characterize 60Co sealed radiation source use in RDD.

  2. Monitor inspection device

    International Nuclear Information System (INIS)

    Ueshima, Yoshinobu.

    1995-01-01

    The device of the present invention reliably conducts monitoring by radiation monitors in a nuclear power plant thereby contributing to save the number of radiation operators and reduction of radiation exposure. Namely, radiation monitors continuously measure a plurality of γ-ray levels. A branched simultaneously counting circuit receives these signals. The output of the branched simultaneously counting circuit is inputted to a differentiation means. The differentiation means calculates a variation coefficient for each of the radiation monitoring values, namely, equivalent dose rates, and records and monitors change with time of the equivalent dose rates. With such procedures, the results of the monitoring of γ-ray levels can be judged objectively corresponding to the increase of the equivalent dose rates. As a result, the number of radiation operators can be saves and radiation exposure of the radiation operators can be reduced. (I.S.)

  3. Density measurement using gamma radiation - theory and application

    International Nuclear Information System (INIS)

    Springer, E.K.

    1979-01-01

    There are still widespread uncertainties about the use and safety of gamma radiation in industries. This paper describes, by the example of radiometric density measurement, the theory of gamma radiation. The differences and advantages of both types of detectors, the ionization chamber and the scintillation counter, are discussed. The degree of accuracy which can be expected from the radiometric density meter will be defined, and the inter-relationship: source strength - measuring range - measuring length(normally the pipe diameter) in relation to the measuring accuracy required will be explained in detail. The use of radioactive material requires the permission of the Atomic Energy Board. The formalities involved to receive a user's licence and the implementations of safety standards set by the local authorities are discussed in depth [af

  4. Influence of burn-in on total-ionizing-dose effect of SRAM device

    International Nuclear Information System (INIS)

    Liu Minbo; Yao Zhibin; Huang Shaoyan; He Baoping; Sheng Jiangkun

    2014-01-01

    The influence of Burn-in on the total-ionizing-dose (TID) effect of SRAM device was investigated. SRAM devices of three different feature sizes were selected and irradiated by "6"0Co source with or without pre-irradiation Burn-in. Some parameters for radiation effect of SRAM device such as upset data, were measured, and the influence on the TID effect of different feature size SRAM devices with or without pre-irradiation Burn-in was obtained. The influence of different temperature Burn-in on radiation resistant capability of SRAM device was studied for 0.25 μm SRAM device. The results show that the smaller the device feature size is, the better the radiation-resistant capability of SRAM device is and the weaker the influence of Burn-in is. And the higher Burn-in temperature is, the more serious the influence of Burn-in on the total-dose radiation effect is. (authors)

  5. Irradiation damages of semiconductor devices and their improvement

    Energy Technology Data Exchange (ETDEWEB)

    Uwatoko, Yoshiya [Saitama Univ., Urawa (Japan); Ohyama, Hidenori; Hayama, Kiyoteru; Hakata, Tetsuya; Kudou, Tomohiro

    1998-01-01

    In this study, effect of radiation on semiconductor devices was evaluated at both sides of electrical and crystalline properties for two years from 1995 fiscal years. And, damage of Si(sub 1-x)Ge(sub x) device was considered at viewpoints of Ge content and sprung-out atomic number and non ionization energy loss of constituting atom formed by radiation on its radiation source dependency of damage. This paper was a report on proton beam damage of the Si(sub 1-x)Ge(sub x) device, neutron damage of InGaAs photodiode, and effect of Ga content and kinds of beam on their damages. (G.K.)

  6. Devices, materials, and processes for nano-electronics: characterization with advanced X-ray techniques using lab-based and synchrotron radiation sources

    International Nuclear Information System (INIS)

    Zschech, E.; Wyon, C.; Murray, C.E.; Schneider, G.

    2011-01-01

    Future nano-electronics manufacturing at extraordinary length scales, new device structures, and advanced materials will provide challenges to process development and engineering but also to process control and physical failure analysis. Advanced X-ray techniques, using lab systems and synchrotron radiation sources, will play a key role for the characterization of thin films, nano-structures, surfaces, and interfaces. The development of advanced X-ray techniques and tools will reduce risk and time for the introduction of new technologies. Eventually, time-to-market for new products will be reduced by the timely implementation of the best techniques for process development and process control. The development and use of advanced methods at synchrotron radiation sources will be increasingly important, particularly for research and development in the field of advanced processes and new materials but also for the development of new X-ray components and procedures. The application of advanced X-ray techniques, in-line, in out-of-fab analytical labs and at synchrotron radiation sources, for research, development, and manufacturing in the nano-electronics industry is reviewed. The focus of this paper is on the study of nano-scale device and on-chip interconnect materials, and materials for 3D IC integration as well. (authors)

  7. Nanoscale Devices for Rectification of High Frequency Radiation from the Infrared through the Visible: A New Approach

    Directory of Open Access Journals (Sweden)

    N. M. Miskovsky

    2012-01-01

    Full Text Available We present a new and viable method for optical rectification. This approach has been demonstrated both theoretically and experimentally and is the basis fot the development of devices to rectify radiation through the visible. This technique for rectification is based not on conventional material or temperature asymmetry as used in MIM (metal/insulator/metal or Schottky diodes, but on a purely sharp geometric property of the antenna. This sharp “tip” or edge with a collector anode constitutes a tunnel junction. In these devices the rectenna (consisting of the antenna and the tunnel junction acts as the absorber of the incident radiation and the rectifier. Using current nanofabrication techniques and the selective atomic layer deposition (ALD process, junctions of 1 nm can be fabricated, which allow for rectification of frequencies up to the blue portion of the spectrum. To assess the viability of our approach, we review the development of nanoantenna structures and tunnel junctions capable of operating in the visible region. In addition, we review the detailed process of rectification and present methodologies for analysis of diode data. Finally, we present operational designs for an optical rectenna and its fabrication and discuss outstanding problems and future work.

  8. Development of an irrigation control device based on solar radiation and its adaptability for cultivation of high soluble solid tomato fruit in root zone restriction culture

    International Nuclear Information System (INIS)

    Nitta, M.; Shibuya, K.; Kubai, K.; Komatsu, H.; Hosokawa, T.; Nakamura, K.

    2009-01-01

    An irrigation control device based on solar radiation was developed to allow automatic irrigation management for high soluble solid tomato fruit production in root zone restriction culture. Its adaptability for long-term cultivation (planting carried out in early September and harvesting ending in late June) of high soluble solid tomato fruit in root zone restriction culture was examined. The following results were obtained: 1. The control device was composed of generally available electronic parts. A change of setting was possible for the irrigation starting point, the irrigation time period, and the once amount of irrigation. For the first irrigation of the day, one of two irrigation control modes can be chosen; the first determines irrigation dependent on the solar radiation after the irrigated time of the previous day. The second mode irrigates at a set time. 2. The correlation between the total integrated solar radiation and the evapotranspiration rate of tomato plants were investigated. Positive correlations were observed for each month from October to June. Moreover, total integrated solar radiation per unit evapotranspiration was different for each month. 3. In long-term cultivation of tomato fruit using this device, the marketable yield of high soluble solid tomato fruit (more than Brix 8%) was 9.7t/10a. 4. This device exhibited the necessary adaptability for use in long-term cultivation of high soluble solid tomato fruit in root zone restriction culture, by changing the set value of the irrigation starting point and the irrigation time period in accordance with the growth period

  9. Effects of device scaling and geometry on MOS radiation hardness assurance

    International Nuclear Information System (INIS)

    Shaneyfelt, M.R.; Fleetwood, D.M.; Winokur, P.S.; Schwank, J.R.; Meisenheimer, T.L.

    1993-01-01

    In this work the authors investigate the effects of transistor scaling and geometry on radiation hardness. The total dose response is shown to depend strongly on transistor channel length. Specifically, transistors with shorter gate lengths tend to show more negative threshold-voltage shifts during irradiation than transistors with longer gate lengths. Similarly, transistors with longer gate lengths tend to show more positive threshold-voltage shifts during post-irradiation annealing than transistors with shorter gate lengths. These differences in radiation response, caused by differences in transistor size and geometry, will be important to factor into test-structure-to-IC correlations necessary to support cost-effective Qualified Manufacturers List (QML) hardness assurance. Transistors with minimum gate length (more negative ΔV th ) will have a larger effect on standby power supply current for an IC at high dose rates, such as in a weapon environment, where worst-case response is associated with negative threshold-voltage shifts during irradiation. On the other hand, transistors with maximum gate length (more positive ΔV th ) will have a larger effect on the timing parameters of an IC at low dose rates, such as in a space environment, where worst-case response is represented by positive threshold-voltage shifts after postirradiation anneal. The channel size and geometry effects they observe cannot be predicted from simple scaling models, but occur because of real differences in oxide-, interface-, and border-trap charge densities among devices of different sizes

  10. Nano scale Devices for Rectification of High Frequency Radiation from the Infrared through the Visible: A New Approach

    International Nuclear Information System (INIS)

    Miskovsky, N.M.; Cutler, P.H.; Miskovsky, N.M.; Cutler, P.H.; Lerne, P.B.; Mayer, A.; Weiss, B.L.; Willis, B.; Sullivan, T.E.

    2012-01-01

    We present a new and viable method for optical rectification. This approach has been demonstrated both theoretically and experimentally and is the basis fot the development of devices to rectify radiation through the visible. This technique for rectification is based not on conventional material or temperature asymmetry as used in MIM (metal/insulator/metal) or Schottky diodes, but on a purely sharp geometric property of the antenna. This sharp tip or edge with a collector anode constitutes a tunnel junction. In these devices the rectenna (consisting of the antenna and the tunnel junction) acts as the absorber of the incident radiation and the rectifier. Using current nano fabrication techniques and the selective atomic layer deposition (ALD) process, junctions of 1?nm can be fabricated, which allow for rectification of frequencies up to the blue portion of the spectrum. To assess the viability of our approach, we review the development of nano antenna structures and tunnel junctions capable of operating in the visible region. In addition, we review the detailed process of rectification and present methodologies for analysis of diode data. Finally, we present operational designs for an optical rectenna and its fabrication and discuss outstanding problems and future work.

  11. Risk evaluation of medical and industrial radiation devices

    International Nuclear Information System (INIS)

    Jones, E.D.; Cunningham, R.E.; Rathbun, P.A.

    1994-03-01

    In 1991, the NRC, Division of Industrial and Medical Nuclear Safety, began a program to evaluate the use of probabilistic risk assessment (PRA) in regulating medical devices. This program represents an initial step in an overall plant to evaluate the use of PRA in regulating the use of nuclear by-product materials. The NRC envisioned that the use of risk analysis techniques could assist staff in ensuring that the regulatory approach was standardized, understandable, and effective. Traditional methods of assessing risk in nuclear power plants may be inappropriate to use in assessing the use of by-product devices. The approaches used in assessing nuclear reactor risks are equipment-oriented. Secondary attention is paid to the human component, for the most part after critical system failure events have been identified. This paper describes the risk methodology developed by Lawrence Livermore National Laboratory (LLNL), initially intended to assess risks associated with the use of the Gamma Knife, a gamma stereotactic radiosurgical device. For relatively new medical devices such as the Gamma Knife, the challenge is to perform a risk analysis with very little quantitative data but with an important human factor component. The method described below provides a basic approach for identifying the most likely risk contributors and evaluating their relative importance. The risk analysis approach developed for the Gamma Knife and described in this paper should be applicable to a broader class of devices in which the human interaction with the device is a prominent factor. In this sense, the method could be a prototypical model of nuclear medical or industrial device risk analysis

  12. Effect of radiofrequency radiation from Wi-Fi devices on mercury release from amalgam restorations.

    Science.gov (United States)

    Paknahad, Maryam; Mortazavi, S M J; Shahidi, Shoaleh; Mortazavi, Ghazal; Haghani, Masoud

    2016-01-01

    Dental amalgam is composed of approximately 50% elemental mercury. Despite concerns over the toxicity of mercury, amalgam is still the most widely used restorative material. Wi-Fi is a rapidly using local area wireless computer networking technology. To the best of our knowledge, this is the first study that evaluates the effect of exposure to Wi-Fi signals on mercury release from amalgam restorations. Standard class V cavities were prepared on the buccal surfaces of 20 non-carious extracted human premolars. The teeth were randomly divided into 2 groups (n = 10). The control group was stored in non-environment. The specimens in the experimental groups were exposed to a radiofrequency radiation emitted from standard Wi Fi devices at 2.4 GHz for 20 min. The distance between the Wi-Fi router and samples was 30 cm and the router was exchanging data with a laptop computer that was placed 20 m away from the router. The concentration of mercury in the artificial saliva in the groups was evaluated by using a cold-vapor atomic absorption Mercury Analyzer System. The independent t test was used to evaluate any significant differences in mercury release between the two groups. The mean (±SD) concentration of mercury in the artificial saliva of the Wi-Fi exposed teeth samples was 0.056 ± .025 mg/L, while it was only 0.026 ± .008 mg/L in the non-exposed control samples. This difference was statistically significant (P =0.009). Exposure of patients with amalgam restorations to radiofrequency radiation emitted from conventional Wi-Fi devices can increase mercury release from amalgam restorations.

  13. Why develop open-source software? The role of non-pecuniary benefits, monetary rewards, and open-source licence type

    OpenAIRE

    Robert M. Sauer

    2007-01-01

    A review of the basic theory of optimal open-source software contributions points to three key factors affecting the decision to contribute to the open-source development process: nonpecuniary benefits, future expected monetary returns, and open-source licence type. This paper argues that existing large-scale software developer surveys are inadequate for measuring the relative importance of these three factors. Previous econometric studies that collect their own unique datasets also fall shor...

  14. Miniaturized radiation chirper

    International Nuclear Information System (INIS)

    Umbarger, C.J.; Wolf, M.A.

    1980-01-01

    A miniaturized radiation chirper for use with a small battery supplying on the order of 5 volts is described. A poor quality CdTe crystal which is not necessarily suitable for high resolution gamma ray spectroscopy is incorporated with appropriate electronics so that the chirper emits an audible noise at a rate that is proportional to radiation exposure level. The chirper is intended to serve as a personnel radiation warning device that utilizes new and novel electronics with a novel detector, a CdTe crystal. The resultant device is much smaller and has much longer battery life than existing chirpers

  15. Measurement of the radiation incident on ALS NdFeB permanent magnet insertion device structures and a determination of their lifetime

    International Nuclear Information System (INIS)

    Krebs, G.F.; Holmes, M.

    1997-05-01

    Measurements of the radiation incident on ALS insertion device NdFeB permanent magnet structures were carried out using thermoluminescence dosimeters. A plastic scintillator gamma telescope was utilized to unravel the various contributions to the integrated dose. Magnet lifetimes were calculated for various operational conditions

  16. Radiation practices 1996

    International Nuclear Information System (INIS)

    Havukainen, R.

    1997-05-01

    At the end of 1996, there were 1,762 valid safety licences in Finland for the use of radiation. In addition, there were 2,052 responsible parties for dental x-ray diagnostics. The registry of the Finnish Centre for Radiation and Nuclear Safety listed 13,360 radiation sources and 313 radionuclide laboratories. The import of radioactive substances amounted to 1.14 x 10 +16 Bq and export to 7.78 x 10 +13 Bq. A total of 4.02 x 10 +13 Bq of short-lived radionuclides were produced in Finland. There were 11,842 workers monitored for radiation exposure at 1,352 work sites. Of these employees, 27% received an annual dose exceeding the recording level. The total dose recorded in the dose registry (sum of individual dosimeter readings) was 7.96 manSv in 1996, with nuclear power plant workers accounting for 69% of this total. The annual dosimeter reading of ten medical doctors (radiologists, interventional radiologists and cardiologists) and eight nuclear power plant employees was equal to or in excess of 20 mSv. Effective doses, however, did not exceed the dose limit of 50 mSv established for one-year monitoring periods. The sum of dosimeter readings (depth dose) on the lead-rubber apron of one interventional radiologist was 242 mSv. It was verified that the annual dose limit for the lens of the eye, 150 mSv, had been exceeded in this case. This high dose was caused by the fact that the radiologist had carried out multiple examinations where unusually high exposure to radiation was an unavoidable part of the task. Report was made of 12 incidents of anomalies in the use of radiation. None of these proved to have caused significant radiation exposure to the radiation source operators. Five of these cases occurred in radiotherapy, three in use of a radiation source in industry, three in transport of radiation sources and one in use of solarium appliances. Radiation-contaminated material was found in 17 shipments of scrap. (orig.)

  17. Radiation practices 1996

    Energy Technology Data Exchange (ETDEWEB)

    Havukainen, R. [ed.

    1997-05-01

    At the end of 1996, there were 1,762 valid safety licences in Finland for the use of radiation. In addition, there were 2,052 responsible parties for dental x-ray diagnostics. The registry of the Finnish Centre for Radiation and Nuclear Safety listed 13,360 radiation sources and 313 radionuclide laboratories. The import of radioactive substances amounted to 1.14 x 10{sup +16} Bq and export to 7.78 x 10{sup +13} Bq. A total of 4.02 x 10{sup +13} Bq of short-lived radionuclides were produced in Finland. There were 11,842 workers monitored for radiation exposure at 1,352 work sites. Of these employees, 27% received an annual dose exceeding the recording level. The total dose recorded in the dose registry (sum of individual dosimeter readings) was 7.96 manSv in 1996, with nuclear power plant workers accounting for 69% of this total. The annual dosimeter reading of ten medical doctors (radiologists, interventional radiologists and cardiologists) and eight nuclear power plant employees was equal to or in excess of 20 mSv. Effective doses, however, did not exceed the dose limit of 50 mSv established for one-year monitoring periods. The sum of dosimeter readings (depth dose) on the lead-rubber apron of one interventional radiologist was 242 mSv. It was verified that the annual dose limit for the lens of the eye, 150 mSv, had been exceeded in this case. This high dose was caused by the fact that the radiologist had carried out multiple examinations where unusually high exposure to radiation was an unavoidable part of the task. Report was made of 12 incidents of anomalies in the use of radiation. None of these proved to have caused significant radiation exposure to the radiation source operators. Five of these cases occurred in radiotherapy, three in use of a radiation source in industry, three in transport of radiation sources and one in use of solarium appliances. Radiation-contaminated material was found in 17 shipments of scrap. (orig.)

  18. Microwave warning device

    International Nuclear Information System (INIS)

    Shriner, W.

    1981-01-01

    A device for warning a person carrying or wearing it of the presence of dangerous microwave radiation is fully powered by the radiations being detected. A very low-wattage gas-discharge lamp is energized by a broadly or a sharply tuned receiver circuit including dipole antennas or one antenna and a ''grounding'' casing element. The casing may be largely and uniformly transparent or have different areas gradedly light-transmissive to indicate varying radiation intensities. The casing can be made in the shape of a pocket watch, fountain pen, bracelet or finger ring, etc

  19. A device for the application of uniaxial strain to single crystal samples for use in synchrotron radiation experiments

    Energy Technology Data Exchange (ETDEWEB)

    Gannon, L. [Clarendon Laboratory, University of Oxford Physics Department, Parks Road, Oxford OX1 3PU (United Kingdom); Diamond Light Source, Harwell Science and Innovation Campus, Didcot OX11 ODE (United Kingdom); Bosak, A. [European Synchrotron Radiation Facility, BP 220, F-38043 Grenoble Cedex (France); Burkovsky, R. G. [European Synchrotron Radiation Facility, BP 220, F-38043 Grenoble Cedex (France); Peter the Great Saint-Petersburg Polytechnic University, 29 Politekhnicheskaya, 195251, St.-Petersburg (Russian Federation); Nisbet, G.; Hoesch, M., E-mail: Moritz.Hoesch@diamond.ac.uk [Diamond Light Source, Harwell Science and Innovation Campus, Didcot OX11 ODE (United Kingdom); Petrović, A. P. [DPMC-MaNEP, Université de Genève, Quai Ernest-Ansermet 24, 1211 Genève 4 (Switzerland)

    2015-10-15

    We present the design, construction, and testing of a straining device compatible with many different synchrotron radiation techniques, in a wide range of experimental environments (including low temperature, high field and ultra-high vacuum). The device has been tested by X-ray diffraction on single crystal samples of quasi-one-dimensional Cs{sub 2}Mo{sub 6}Se{sub 6} and K{sub 2}Mo{sub 6}Se{sub 6}, in which microscopic strains up to a Δc/c = 0.12% ± 0.01% change in the c lattice parameters have been achieved. We have also used the device in an inelastic X-ray scattering experiment, to probe the strain-dependent speed of sound ν along the c axis. A reduction Δν/ν of up to −3.8% was obtained at a strain of Δc/c = 0.25% in K{sub 2}Mo{sub 6}Se{sub 6}.

  20. Legitimacy, credibility and trust as the key components of a Social Licence to operate : An analysis of BP’s projects in Georgia

    NARCIS (Netherlands)

    Vanclay, Francis; Jijelava, David

    2017-01-01

    We consider the extent to which the concept of Social Licence to Operate can be applied in actual practice by considering BP's activities in Georgia, especially the Baku-Tbilisi-Ceyhan and Southern Caucasus Pipeline projects. We adapt the model originally developed by Thomson and Boutilier,

  1. Ionizing secondary radiation generated by analog radiological and digital coronary cine angiographic equipment. Influence of external protection devices

    International Nuclear Information System (INIS)

    Ramirez N, Alfredo; Farias Ch, Eric; Silva J, Ana Maria; Leyton L, Fernando; Oyarzun C, Carlos; Ugalde P, Hector; Dussaillant, Gaston; Cumsille G, Angel

    2000-01-01

    Exposure to ionizing radiation is a know hazard of radiological procedures. Aim: to compare the emission of secondary ionizing radiation from two coronary angiographic equipments, one with digital and the other with analog image generation. To evaluate the effectiveness of external radiological protection devices. Material and methods: environmental and fluoroscopy generated radiation in the cephalic region of the patient was measured during diagnostic coronary angiographies. Ionizing radiation generated in anterior left oblique protection (ALO) and anterior right oblique protection (ARO) were measured with and without leaded protections. In 19 patients (group 1), a digital equipment was used and in 21 (group 2), an analog equipment. Results: header radiation for group 1 and 2 was 1194±337 and 364±222 μGray/h respectively (p≤0.001). During fluoroscopy and with leaded protection generated radiation for groups 1 and 2 was 612±947 and 70±61μGray/h respectively (p≤0.001). For ALO projection, generated for groups 1 and 2 was 105±47 and 71±192 μGray/h respectively (p≤0.001). During filming the radiation for ALO projection for groups 1 and 2 was 7252±9569 and 1671±2038 μGray/h respectively (p=0.03). Out of the protection zone, registered radiation during fluoroscopy for groups 1 and 2 was 2800±1741 and 1318±954 μGray/h respectively (p≤0.001); during filming, the figures were 15500±5840 and 18961±10599 μGray/h respectively (NS). Conclusions: digital radiological equipment has a lower level of ionizing radiation emission than the analog equipment

  2. Cooling device in thermonuclear device

    International Nuclear Information System (INIS)

    Honda, Tsutomu.

    1988-01-01

    Purpose: To prevent loss of cooling effect over the entire torus structure directly after accidental toubles in a cooling device of a thermonuclear device. Constitution: Coolant recycling means of a cooling device comprises two systems, which are alternately connected with in-flow pipeways and exit pipeways of adjacent modules. The modules are cooled by way of the in-flow pipeways and the exist pipeways connected to the respective modules by means of the coolant recycling means corresponding to the respective modules. So long as one of the coolant recycling means is kept operative, since every one other modules of the torus structure is still kept cooled, the heat generated from the module put therebetween, for which the coolant recycling is interrupted, is removed by means of heat conduction or radiation from the module for which the cooling is kept continued. No back-up emergency cooling system is required and it can provide high economic reliability. (Kamimura, M.)

  3. Safety work with MRI devices in medicine

    International Nuclear Information System (INIS)

    Zivkovic, D.; Hrnjak, M.

    1999-01-01

    This paper gives the basis of biological effects of physical factors which could affect personnel working on MRI devices and patients, and corresponding protection measures. Medical personnel working with MRI devices and patients could be exposed to static magnetic field, time varying fields and radiofrequency radiation, danger from electric current and chemical matters, and there is a high risk from moving metal objects which could wound the persons near-by. The protection from static magnetic field could be ensured by increasing the distance from the source. If MRI device is put in Faradays cage it could be corresponding protection of radiofrequency radiation. (author)

  4. Absorption Related to Hand-Held Devices in Data Mode

    DEFF Research Database (Denmark)

    Andersen, Jørgen Bach; Nielsen, Jesper Ødum; Pedersen, Gert F.

    2016-01-01

    The human body has an influence on the radiation from handheld devices like smartphones, tablets and laptops, part of the energy is absorbed and the spatial distribution of the radiated part is modified. Previous studies of whole body absorp- tion have mainly been numerical or related to talk mode....... In the present paper an experimental study involving four volunteers and three different devices is performed from 0.5 to 3 GHz. The devices are a laptop, a tablet, and a smartphone all held in the lap. The 3D distribution of radiation is measured. Comparing the integrated power in the case of a person present...

  5. Evaluation of image quality for various electronic portal imaging devices in radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Son, Soon Yong; Choi, Kwan Woo [Dept. of Radiology, Asan Medical Center, Seoul (Korea, Republic of); Kim, Jung Min [Dept. of College of Health Science, Radiologic Science, Korea University, Seoul (Korea, Republic of); and others

    2015-12-15

    In megavoltage (MV) radiotherapy, delivering the dose to the target volume is important while protecting the surrounding normal tissue. The purpose of this study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) using an edge block in megavoltage X-ray imaging (MVI). We used an edge block, which consists of tungsten with dimensions of 19 (thickness) × 10 (length) × 1 (width) cm3 and measured the pre-sampling MTF at 6 MV energy. Various radiation therapy (RT) devices such as TrueBeamTM (Varian), BEAMVIEWPLUS (Siemens), iViewGT (Elekta) and Clinac®iX (Varian) were used. As for MTF results, TrueBeamTM(Varian) flattening filter free(FFF) showed the highest values of 0.46 mm-1and1.40mm-1for MTF 0.5 and 0.1. In NPS, iViewGT (Elekta) showed the lowest noise distribution. In DQE, iViewGT (Elekta) showed the best efficiency at a peak DQE and 1 mm-1DQE of 0.0026 and 0.00014, respectively. This study could be used not only for traditional QA imaging but also for quantitative MTF, NPS, and DQE measurement for development of an electronic portal imaging device (EPID)

  6. Space radiation effects

    International Nuclear Information System (INIS)

    Li Shiqing; Yan Heping

    1995-01-01

    The authors briefly discusses the radiation environment in near-earth space and it's influences on material, and electronic devices using in space airship, also, the research developments in space radiation effects are introduced

  7. Radiation protection measuring device SSM-1

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    Product information from the producer on a universal measuring instrument for alpha, beta and gamma radiation designed for stationary and field use by military, police and fire brigades. 4 figs. (qui)

  8. Digital communication device

    DEFF Research Database (Denmark)

    2005-01-01

    The invention concerns a digital communication device like a hearing aid or a headset. The hearing aid or headset has a power supply, a signal processing device, means for receiving a wireless signal and a receiver or loudspeaker, which produces an audio signal based on a modulated pulsed signal...... point is provided which is in electrical contact with the metal of the metal box and whereby this third connection point is connected to the electric circuitry of the communication device at a point having a stable and well defined electrical potential. In this way the electro-and magnetic radiation...

  9. SU-E-J-48: Development of An Abdominal Compression Device for Respiratory Correlated Radiation Therapy

    International Nuclear Information System (INIS)

    Kim, T; Kang, S; Kim, D; Suh, T; Kim, S

    2014-01-01

    Purpose: The aim of this study is to develop the abdominal compression device which could control pressure level according to the abdominal respiratory motion and evaluate its feasibility. Methods: In this study, we focused on developing the abdominal compression device which could control pressure level at any point of time so the developed device is possible to use a variety of purpose (gating technique or respiratory training system) while maintaining the merit of the existing commercial device. The compression device (air pad form) was designed to be able to compress the front and side of abdomen and the pressure level of the abdomen is controlled by air flow. Pressure level of abdomen (air flow) was determined using correlation data between external abdominal motion and respiratory volume signal measured by spirometer. In order to verify the feasibility of the device, it was necessary to confirm the correlation between the abdominal respiratory motion and respiratory volume signal and cooperation with respiratory training system also checked. Results: In the previous study, we could find that the correlation coefficient ratio between diaphragm and respiratory volume signal measured by spirometer was 0.95. In this study, we confirmed the correlation between the respiratory volume signal and the external abdominal motion measured by belt-transducer (correlation coefficient ratio was 0.92) and used the correlated respiratory volume data as an abdominal pressure level. It was possible to control the pressure level with negligible time delay and respiratory volume data based guiding waveforms could be properly inserted into the respiratory training system. Conclusion: Through this feasibility study, we confirmed the correlation between the respiratory volume signal and the external abdominal motion. Also initial assessment of the device and its compatibility with the respiratory training system were verified. Further study on application in respiratory gated

  10. Radiation sources safety and radioactive materials security regulation in Ukraine

    International Nuclear Information System (INIS)

    Smyshliaiev, A.; Holubiev, V.; Makarovska, O.

    2001-01-01

    Radiation sources are widely used in Ukraine. There are about 2500 users in industry, science, education and about 2800 in medicine. About 80,000 sealed radiation sources with total kerma-equivalent of 450 Gy*M 2 /sec are used in Ukraine. The exact information about the radiation sources and their users will be provided in 2001 after the expected completion of the State inventory of radiation sources in Ukraine. In order to ensure radiation source safety in Ukraine, a State System for regulation of activities dealing with radiation sources has been established. The system includes the following elements: establishment of norms, rules and standards of radiation safety; authorization activity, i.e. issuance of permits (including those in the form of licences) for activities dealing with radiation sources; supervisory activity, i.e. control over observance of norms, rules and standards of radiation safety and fulfilment of conditions of licences for activities dealing with radiation sources, and also enforcement. Comprehensive nuclear legislation was developed and implemented from 1991 to 2000. Radiation source safety is regulated by three main nuclear laws in Ukraine: On the use of nuclear energy and radiation safety (passed on 8 February 1995); On Human Protection from Impact of Ionizing Radiation (passed on 14 January 1998); On permissive activity in the area of nuclear energy utilization (passed on 11 January 2000). The regulatory authorities in Ukraine are the Ministry for Ecology and Natural Resources (Nuclear Regulatory Department) and the Ministry of Health (State sanitary-epidemiology supervision). According to the legislation, activities dealing with radiation sources are forbidden without an officially issued permit in Ukraine. Permitted activities with radiation sources are envisaged: licensing of production, storage and maintenance of radiation sources; licensing of the use of radiation sources; obligatory certification of radiation sources and transport

  11. 47 CFR 15.13 - Incidental radiators.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Incidental radiators. 15.13 Section 15.13 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES General § 15.13 Incidental radiators. Manufacturers of these devices shall employ good engineering practices to minimize the risk of...

  12. Optoelectronic device with nanoparticle embedded hole injection/transport layer

    Science.gov (United States)

    Wang, Qingwu [Chelmsford, MA; Li, Wenguang [Andover, MA; Jiang, Hua [Methuen, MA

    2012-01-03

    An optoelectronic device is disclosed that can function as an emitter of optical radiation, such as a light-emitting diode (LED), or as a photovoltaic (PV) device that can be used to convert optical radiation into electrical current, such as a photovoltaic solar cell. The optoelectronic device comprises an anode, a hole injection/transport layer, an active layer, and a cathode, where the hole injection/transport layer includes transparent conductive nanoparticles in a hole transport material.

  13. A method and device for reducing background in well logging devices using inelastic gamma rays

    International Nuclear Information System (INIS)

    Culver, R.B.

    1974-01-01

    The invention relates to a well logging device, of the type comprising a source of pulsed neutrons and means for detecting radioactivity. The device comprises means adapted to interrupt the neutron source emission in response to the detection of a single gamma radiation showing a pre-determined feature [fr

  14. Pneumatic radiator of transition radiation for large working area arrangements

    International Nuclear Information System (INIS)

    Shikhlyarov, K.K.; Gavalyan, V.G.

    1993-01-01

    An unconventional approach to the constructions of large area regular radiator of X-rays transition radiation is proposed based on the use of a pack of hermetically sealed bags, in which elastic helium layers are formed. A prototype of such a radiator of about 1m 2 area was made for test of the proposed device. 9 refs

  15. Design, construction, and in vivo feasibility of a positioning device for irradiation of mice brains using a clinical linear accelerator and intensity modulated radiation therapy.

    Science.gov (United States)

    Rancilio, Nicholas J; Dahl, Shaun; Athanasiadi, Ilektra; Perez-Torres, Carlos J

    2017-12-01

    The goal of this study was to design a positioning device that would allow for selective irradiation of the mouse brain with a clinical linear accelerator. We designed and fabricated an immobilization fixture that incorporates three functions: head stabilizer (through ear bars and tooth bar), gaseous anesthesia delivery and scavenging, and tissue mimic/bolus. Cohorts of five mice were irradiated such that each mouse in the cohort received a unique dose between 1000 and 3000 cGy. DNA damage immunohistochemistry was used to validate an increase in biological effect as a function of radiation dose. Mice were then followed with hematoxylin and eosin (H&E) and anatomical magnetic resonance imaging (MRI). There was evidence of DNA damage throughout the brain proportional to radiation dose. Radiation-induced damage at the prescribed doses, as depicted by H&E, appeared to be constrained to the white matter consistent with radiological observation in human patients. The severity of the damage correlated with the radiation dose as expected. We have designed and manufactured a device that allows us to selectively irradiate the mouse brain with a clinical linear accelerator. However, some off-target effects are possible with large prescription doses.

  16. Examination system utilizing ionizing radiation and a flexible, miniature radiation detector probe

    Science.gov (United States)

    Majewski, Stanislaw; Kross, Brian J.; Zorn, Carl J.; Majewski, Lukasz A.

    1996-01-01

    An optimized examination system and method based on the Reverse Geometry X-Ray.RTM. (RGX.RTM.) radiography technique are presented. The examination system comprises a radiation source, at least one flexible, miniature radiation detector probe positioned in appropriate proximity to the object to be examined and to the radiation source with the object located between the source and the probe, a photodetector device attachable to an end of the miniature radiation probe, and a control unit integrated with a display device connected to the photodetector device. The miniature radiation detector probe comprises a scintillation element, a flexible light guide having a first end optically coupled to the scintillation element and having a second end attachable to the photodetector device, and an opaque, environmentally-resistant sheath surrounding the flexible light guide. The probe may be portable and insertable, or may be fixed in place within the object to be examined. An enclosed, flexible, liquid light guide is also presented, which comprises a thin-walled flexible tube, a liquid, preferably mineral oil, contained within the tube, a scintillation element located at a first end of the tube, closures located at both ends of the tube, and an opaque, environmentally-resistant sheath surrounding the flexible tube. The examination system and method have applications in non-destructive material testing for voids, cracks, and corrosion, and may be used in areas containing hazardous materials. In addition, the system and method have applications for medical and dental imaging.

  17. Revoking a nuclear licence on account of serious hazards within the meaning of Art. 17 subsection 5 Atomic Energy Act

    International Nuclear Information System (INIS)

    Kunth, B.

    1990-01-01

    Revocation for these reasons appears on account of separating the preconditions for recvoation from the legitimateness of the licence, and on account of the authority's duty to deliver the - justified - revocation order, a suitable instrument to enforce decommissioning of nuclear power plants along the lines of continguity risk actions, however, with limited scope in practical application because of the tight precondition elements for a case. (orig.) [de

  18. Device simulation of charge collection and single-event upset

    International Nuclear Information System (INIS)

    Dodd, P.E.

    1996-01-01

    In this paper the author reviews the current status of device simulation of ionizing-radiation-induced charge collection and single-event upset (SEU), with an emphasis on significant results of recent years. The author presents an overview of device-modeling techniques applicable to the SEU problem and the unique challenges this task presents to the device modeler. He examines unloaded simulations of radiation-induced charge collection in simple p/n diodes, SEU in dynamic random access memories (DRAM's), and SEU in static random access memories (SRAM's). The author concludes with a few thoughts on future issues likely to confront the SEU device modeler

  19. Effects of gamma radiation on commercial operational amplifiers

    International Nuclear Information System (INIS)

    Claro, Luiz H.; Santos, Jose A. dos

    2009-01-01

    The operational amplifiers are widely used in nuclear instrumentation. Their applications span the signal conditioning circuits, analog instrumentation, amplifiers, converters, oscillators and others. If an operational amplifier is used to work in a radiation environment, the device suffers degradation in its performance leading to the bad work in the systems. Some of these devices are designed as rad-hard components and therefore the effects of radiation damage are minimized, however its main disadvantage is the high cost and difficult to find in the market. As an alternative one can use the conventional electronic components available in the market and named COTS (Commercially Available Off-The-Shelf) but they must be tested under a radiation environment. In this work the effect of the radiation damage is studied in two typical operational amplifiers. Some electric parameters of these devices were measured for different gamma radiation doses and they were working at different input signal frequencies. A 60 Co isotopic radiation source was used and the results show that there is a certain degradation of the device depending on the radiation absorbed dose. (author)

  20. A novel device for automatic withdrawal and accurate calibration of 99m-technetium radiopharmaceuticals to minimise radiation exposure to nuclear medicine staff and patient

    International Nuclear Information System (INIS)

    Nazififard, M.; Mahdizadeh, S.; Meigooni, A. S.; Alavi, M.; Suh, K. Y.

    2012-01-01

    A Joint Automatic Dispenser Equipment (JADE) has been designed and fabricated for automatic withdrawal and calibration of radiopharmaceutical materials. The thermoluminescent dosemeter procedures have shown a reduction in dose to the technician's hand with this novel dose dispenser system JADE when compared with the manual withdrawal of 99m Tc. This system helps to increase the precision of calibration and to minimise the radiation dose to the hands and body of the workers. This paper describes the structure of this device, its function and user-friendliness, and its efficacy. The efficacy of this device was determined by measuring the radiation dose delivered to the hands of the nuclear medicine laboratory technician. The user-friendliness of JADE has been examined. The automatic withdrawal and calibration offered by this system reduces the dose to the technician's hand to a level below the maximum permissible dose stipulated by the international protocols. This research will serve as a backbone for future study about the safe use of ionising radiation in medicine. (authors)

  1. Anisotropic conducting films for electromagnetic radiation applications

    Science.gov (United States)

    Cavallo, Francesca; Lagally, Max G.; Rojas-Delgado, Richard

    2015-06-16

    Electronic devices for the generation of electromagnetic radiation are provided. Also provided are methods for using the devices to generate electromagnetic radiation. The radiation sources include an anisotropic electrically conducting thin film that is characterized by a periodically varying charge carrier mobility in the plane of the film. The periodic variation in carrier mobility gives rise to a spatially varying electric field, which produces electromagnetic radiation as charged particles pass through the film.

  2. BAKNET - Communication network for radiation monitoring devices

    International Nuclear Information System (INIS)

    Cohen, Y.; Wengrowicz, U.; Tirosh, D.; Barak, D.

    1997-01-01

    A system, based on a new concept of controlling and monitoring distributed radiation monitors, has been developed and approved at the NRCN. The system, named B AKNET Network , consists of a series of communication adapters connected to a main PC via an RS-485 communication network (see Fig. 1). The network's maximal length is 1200 meters and it enables connection of up to 128 adapters. The BAKNET adapters are designed to interface output signals of different types of stationary radiation monitors to a main PC. The BAKNET adapters' interface type includes: digital, analog, RS-232, and mixed output signals. This allows versatile interfacing of different stationary radiation monitors to the main computer. The connection to the main computer is via an RS-485 network, utilizing an identical communication protocol. The PC software, written in C ++ under MS-Windows, consists of two main programs. The first is the data collection program and the second is the Human Machine Interface (HMI). (authors)

  3. Improvements in or relating to charge coupled devices

    International Nuclear Information System (INIS)

    Shannon, J.M.

    1980-01-01

    This invention relates to charge coupled devices for converting an electromagnetic radiation pattern in a certain wavelength range, particularly but not exclusively an infrared radiation pattern, into electrical signals. A semiconductor layer within this device can be of n-type silicon with a deep level impurity concentration present as proton bombardment induced defects in the crystal lattice or as an ion implanted concentration. (UK)

  4. Method for on-state measurement, trend analysis and long-term monitoring of radiation exposures in the private environment, and device for implementing the process

    International Nuclear Information System (INIS)

    Jitschin, W.; Kalwar, K.

    1987-01-01

    Plans are made to carry out measurements by means of a radiation detector, to transmit the data to a data processing computer and to display the calculated data on one or several data output devices. The data output device can be a monitor of the computer, a television set, or an electronic printer. The computer can be a cheap, commercially available, programmable minicomputer, a home computer or a personal computer. (orig./HP) [de

  5. Automatic analysis of image quality control for Image Guided Radiation Therapy (IGRT) devices in external radiotherapy

    International Nuclear Information System (INIS)

    Torfeh, Tarraf

    2009-01-01

    On-board imagers mounted on a radiotherapy treatment machine are very effective devices that improve the geometric accuracy of radiation delivery. However, a precise and regular quality control program is required in order to achieve this objective. Our purpose consisted of developing software tools dedicated to an automatic image quality control of IGRT devices used in external radiotherapy: 2D-MV mode for measuring patient position during the treatment using high energy images, 2D-kV mode (low energy images) and 3D Cone Beam Computed Tomography (CBCT) MV or kV mode, used for patient positioning before treatment. Automated analysis of the Winston and Lutz test was also proposed. This test is used for the evaluation of the mechanical aspects of treatment machines on which additional constraints are carried out due to the on-board imagers additional weights. Finally, a technique of generating digital phantoms in order to assess the performance of the proposed software tools is described. Software tools dedicated to an automatic quality control of IGRT devices allow reducing by a factor of 100 the time spent by the medical physics team to analyze the results of controls while improving their accuracy by using objective and reproducible analysis and offering traceability through generating automatic monitoring reports and statistical studies. (author) [fr

  6. Australian radiation protection and nuclear safety (consequential amendments) Bill 1998. Explanatory memorandum

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-31

    The purpose of this Bill is to make consequential changes to the Australian Nuclear Science and Technology Organisation Act 1987 (the ANSTO Act) and to provide for transitional arrangements to cover the operation of controlled facilities and the handling of radiation sources while applications for licences to cover these facilities and activities are being made under the proposed Australian Radiation Protection and Nuclear Safety Act 1998 (the ARPANS Act) For this purpose, the Bill: (a) repeals Parts VI and VII A of the ANSTO Act under which, respectively, the Safety Review Committee and the Nuclear Safety Bureau are established, as the functions of the Committee and Bureau will be transferred to the CEO of the Australian Radiation Protection and Nuclear Safety Agency, established under the ARPANS Act; (b) makes transitional arrangements for the transfer of the assets and liabilities of the Nuclear Safety Bureau to the Commonwealth, and confers on the CEO of ARPANSA the powers of the Director of the Nuclear Safety Bureau in relation to the Australian Nuclear Science and Technology Organisation during the transitional period before the offenses provisions commence to operate under the ARPANS Act; (c) repeals the Environment Protection (Nuclear Codes) Act 1978. That Act provides for the development and endorsement of Codes of Practice which will be undertaken under the auspices of ARPANSA; (d) provides that Commonwealth entities have a transition period of 6 months after the ARPANS Act commences to apply for a licence to authorize specified activities under that Act

  7. Australian radiation protection and nuclear safety (consequential amendments) Bill 1998. Explanatory memorandum

    International Nuclear Information System (INIS)

    1998-01-01

    The purpose of this Bill is to make consequential changes to the Australian Nuclear Science and Technology Organisation Act 1987 (the ANSTO Act) and to provide for transitional arrangements to cover the operation of controlled facilities and the handling of radiation sources while applications for licences to cover these facilities and activities are being made under the proposed Australian Radiation Protection and Nuclear Safety Act 1998 (the ARPANS Act) For this purpose, the Bill: (a) repeals Parts VI and VII A of the ANSTO Act under which, respectively, the Safety Review Committee and the Nuclear Safety Bureau are established, as the functions of the Committee and Bureau will be transferred to the CEO of the Australian Radiation Protection and Nuclear Safety Agency, established under the ARPANS Act; (b) makes transitional arrangements for the transfer of the assets and liabilities of the Nuclear Safety Bureau to the Commonwealth, and confers on the CEO of ARPANSA the powers of the Director of the Nuclear Safety Bureau in relation to the Australian Nuclear Science and Technology Organisation during the transitional period before the offenses provisions commence to operate under the ARPANS Act; (c) repeals the Environment Protection (Nuclear Codes) Act 1978. That Act provides for the development and endorsement of Codes of Practice which will be undertaken under the auspices of ARPANSA; (d) provides that Commonwealth entities have a transition period of 6 months after the ARPANS Act commences to apply for a licence to authorize specified activities under that Act

  8. In-service training and expertise requirements in radiation protection

    International Nuclear Information System (INIS)

    Klener, V.; Heribanova, A.

    2003-01-01

    Proper selection of staff and their special education and training in radiation protection are important factors when assuring faultless man-machine interaction and thereby a reduced likelihood of human factor failure in hazardous practices. University-level institutions can only provide education in the individual partial segments of the multidisciplinary area of radiation protection, whereas the proper practices are learned by graduate personnel on the job, by performing operational tasks at their particular workplace. The scope o expertise of subjects providing radiation protection surveillance and the requirements for their special education and training are outlined. Supervising persons appointed by the radiation source handling licensee to perform a number of operational tasks at the workplace assume a prominent position. Alternatively, systematic supervision at the workplace can be contracted by the licensee from an external body, provided that the latter has acquired appropriate licence from the State Office for Nuclear Safety. The provisions of the Atomic Act and the related implementing regulations with respect to special training and to the examination of professional competence before an expert commission are briefly outlined. (author)

  9. Non-destructive screening method for radiation hardened performance of large scale integration

    International Nuclear Information System (INIS)

    Zhou Dong; Xi Shanbin; Guo Qi; Ren Diyuan; Li Yudong; Sun Jing; Wen Lin

    2013-01-01

    The space radiation environment could induce radiation damage on the electronic devices. As the performance of commercial devices is generally superior to that of radiation hardened devices, it is necessary to screen out the devices with good radiation hardened performance from the commercial devices and applying these devices to space systems could improve the reliability of the systems. Combining the mathematical regression analysis with the different physical stressing experiments, we investigated the non-destructive screening method for radiation hardened performance of the integrated circuit. The relationship between the change of typical parameters and the radiation performance of the circuit was discussed. The irradiation-sensitive parameters were confirmed. The pluralistic linear regression equation toward the prediction of the radiation performance was established. Finally, the regression equations under stress conditions were verified by practical irradiation. The results show that the reliability and accuracy of the non-destructive screening method can be elevated by combining the mathematical regression analysis with the practical stressing experiment. (authors)

  10. Radiation environment of fusion experimental reactor

    International Nuclear Information System (INIS)

    Mori, Seiji; Seki, Yasushi

    1988-01-01

    Next step device (experimental reactor), which is planned to succeed the large plasma experimental devices such as JT-60, JET and TFTR, generates radiation (neutron + gamma ray) during its operation. Radiation (neutronic) properties of the material are basis for the study on neutron utilization (energy recovery and tritium breeding), material selection (irradiation damage and lifetime evaluation) and radiation safety (personnel exposure and radiation waste). It is necessary, therefore, to predict radiation behaviour in the reactor correctly for the engineering design of the reactor. This report describes the outline of the radiation environment of the reactor based on the information obtained by the neutronic and shielding design calculation of the fusion experimental reactor (FER). (author)

  11. Radiation-hardened CMOS integrated circuits

    International Nuclear Information System (INIS)

    Derbenwick, G.F.; Hughes, R.C.

    1977-01-01

    Electronic circuits that operate properly after exposure to ionizing radiation are necessary for nuclear weapon systems, satellites, and apparatus designed for use in radiation environments. The program to develop and theoretically model radiation-tolerant integrated circuit components has resulted in devices that show an improvement in hardness up to a factor of ten thousand over earlier devices. An inverter circuit produced functions properly after an exposure of 10 6 Gy (Si) which, as far as is known, is the record for an integrated circuit

  12. Development of a daily dosimetric control for radiation therapy using an electronic portal imaging device (EPID)

    International Nuclear Information System (INIS)

    Saboori, Mohammadsaeed

    2015-01-01

    Electronic Portal Imaging Devices (EPIDs) can be used to perform dose measurements during radiation therapy treatments if dedicated calibration and correction procedures are applied. The purpose of this study was to provide a new calibration and correction model for an amorphous silicon (a-Si) EPID for use in transit dose verification of step-and-shoot intensity modulated radiation therapy (IMRT). A model was created in a commercial treatment planning system to calculate the nominal two-dimensional (2D) dose map of each radiation field at the EPID level. The EPID system was calibrated and correction factors were determined using a reference set-up, which consisted a patient phantom and an EPID phantom. The advantage of this method is that for the calibration, the actual beam spectrum is used to mimic a patient measurement. As proof-of-principle, the method was tested for the verification of two 7-field IMRT treatment plans with tumor sites in the head-and-neck and pelvic region. Predicted and measured EPID responses were successfully compared to the nominal data from treatment planning using dose difference maps and gamma analyses. Based on our result it can be concluded that this new method of 2D EPID dosimetry is a potential tool for simple patient treatment fraction dose verification.

  13. Radiation protection at urological fluoroscopy working stations

    International Nuclear Information System (INIS)

    Forster, D.; Mohr, H.

    1979-01-01

    Two newly developed radiation protection devices for urological working stations are presented. The local dose to which doctor and assisting personnel are exposed during fluoroscopy and radiography was measured and the radiation burden with and without radiation protection determined. The studies show that without these devices organs such as the eyes are exposed, at a normal working distance from the table, to such an amount of scattered radiation as to reduce the permitted number of examinations per week. (Auth.)

  14. Radiation protection training programmes Spanish approach

    International Nuclear Information System (INIS)

    Arboli, M. Marco; Suarez, M. Rodriguez; Cabrera, S. Falcon

    2002-01-01

    Radiation Protection Programmes are being considered the best way to promote safety culture and to spread and propagate European basic safety standards. It is widely accepted that training is an important tool to upgrade competence for radiation exposed workers. The Spanish Radiation Protection Education and Training Programmes provide a solid and integrated educational model, which takes into account the variety of applied fields, the different levels of responsibilities, the technological and methodological advances, as well as the international tendencies. The needs for a specialised training on Radiation Protection (RP) for exposed workers appears into the Spanish regulation in 1964. National initial training programmes are well established since 1972. Individual certifications, based on personal licences are required for exposed workers. The Spanish regulation also includes continuous and on the job RP training. The educational programmes are being continuously updating and improving. CIEMAT plays an important role in RP Spanish training, improving and modifying the previous RP courses and developing new programmes in order to complete the RP training levels. To achieve Radiation Protection objectives, new technological media for educational methods and material are taking into account. Nevertheless, Spanish RP education and training model has to be improved in some aspects. The purpose of this paper is to analyse the situation and the future needs to be considered in order to complete the RP training processes

  15. Radiation effects in semiconductor laser diode arrays

    International Nuclear Information System (INIS)

    Carson, R.F.

    1988-01-01

    The effects of radiation events are important for many of the present and future applications that involve optoelectronic components. Laser diodes show a strong resistance to degradation by gamma rays, prompt x-rays and (to a lesser extent), neutrons. This is due to the short carrier lifetime that is associated with stimulated emission and the high current injection conditions that are present in these devices. Radiation-resistant properties should carry over to many of the more recently developed devices such as multi-stripe array and broad area laser diodes. There are, however, additional considerations for radiation tolerance that are introduced by these devices. Arrays and other high power laser diodes have larger active region volumes than lower power single stripe devices. In addition, evanescent field coupling between stripes, the material quality available from newer MOCVD epitaxial growth techniques, and stripe definition methods may all influence the radiation tolerance of the high power laser diode devices. Radiation tests have been conducted on various GaAs-GaAlAs laser diode array and broad area devices. Tests involving total gamma dose have indicated that high power laser diodes and arrays have small degradations in light power output with current input after 4 MRad(Si) of radiation from a Co 60 source. Additional test results involving flash x-rays indicate that high power diode lasers and arrays are tolerant to 10 12 rads(Si)/sec, when observed on microsecond or millisecond time scales. High power diode laser devices were also irradiated with neutrons to a fluence of 10 14 neutrons/cm 2 with some degradation of threshold current level

  16. Cervix-to-rectum measuring device in a radiation applicator for use in the treatment of cervical cancer

    International Nuclear Information System (INIS)

    Fischell, D.R.; Mazique, J.C.

    1981-10-01

    A cervix-to-rectum measuring device to be used in the treatment of cervical cancer is described. It includes a handle and a probe pivotably connected to the handle for insertion in the rectum. The measuring device further includes means for coupling the handle to an intrauterine radiation applicator when the latter is positioned in the uterine cervix and the probe is inserted in the rectum to pivot the handle about the probe. A gear is provided which is adapted to pivot with the probe. A pinion pivotably connected to the handle meshes with the gear. A pointer fixed to the pinion is displaced in response to the pivoting of the handle about the probe, and this displacement can be read from a scale on the handle, providing an indication of the cervix-to-rectum distance. Official Gazette of the U.S. Patent and Trademark Office

  17. Device for contamination monitoring against radiation contamination of people

    International Nuclear Information System (INIS)

    Rische, U.W.; Gerlach, R.

    1986-01-01

    The monitor has detector devices at an angle to each other made as a rigid component which can be rotated around a vertical axis in the angle between the joined detector devices. A reset drive which can be tensioned is provided at the axis of rotation. If it is in its rest position, a platform is situated as floor plate with a foot detector between the vertical detector devices. (orig./HP) [de

  18. Hardening device, by inserts, of electronic component against radiation

    International Nuclear Information System (INIS)

    Val, C.

    1987-01-01

    The hardening device includes at least two materials, one with high atomic number with respect to the other. One of these materials is set as inserts in a layer of the other material. The hardening device is then made by stacking of such layers, the insert density varying from one layer to the other, making thus vary the atomic number resulting from the hardening device along its thickness, following a predefined law [fr

  19. MULTI2D - a computer code for two-dimensional radiation hydrodynamics

    Science.gov (United States)

    Ramis, R.; Meyer-ter-Vehn, J.; Ramírez, J.

    2009-06-01

    Simulation of radiation hydrodynamics in two spatial dimensions is developed, having in mind, in particular, target design for indirectly driven inertial confinement energy (IFE) and the interpretation of related experiments. Intense radiation pulses by laser or particle beams heat high-Z target configurations of different geometries and lead to a regime which is optically thick in some regions and optically thin in others. A diffusion description is inadequate in this situation. A new numerical code has been developed which describes hydrodynamics in two spatial dimensions (cylindrical R-Z geometry) and radiation transport along rays in three dimensions with the 4 π solid angle discretized in direction. Matter moves on a non-structured mesh composed of trilateral and quadrilateral elements. Radiation flux of a given direction enters on two (one) sides of a triangle and leaves on the opposite side(s) in proportion to the viewing angles depending on the geometry. This scheme allows to propagate sharply edged beams without ray tracing, though at the price of some lateral diffusion. The algorithm treats correctly both the optically thin and optically thick regimes. A symmetric semi-implicit (SSI) method is used to guarantee numerical stability. Program summaryProgram title: MULTI2D Catalogue identifier: AECV_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AECV_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 151 098 No. of bytes in distributed program, including test data, etc.: 889 622 Distribution format: tar.gz Programming language: C Computer: PC (32 bits architecture) Operating system: Linux/Unix RAM: 2 Mbytes Word size: 32 bits Classification: 19.7 External routines: X-window standard library (libX11.so) and corresponding heading files (X11/*.h) are

  20. Designing a Polymerase Chain Reaction Device Working with Radiation and Convection Heat Transfer

    Science.gov (United States)

    Madadelahi, M.; Kalan, K.; Shamloo, A.

    2018-05-01

    Gene proliferation is vital for infectious and genetic diseases diagnosis from a blood sample, even before birth. In addition, DNA sequencing, genetic finger-print analyzing, and genetic mutation detecting can be mentioned as other procedures requiring gene reproduction. Polymerase chain reaction, briefly known as PCR, is a convenient and effective way to accomplish this task; where the DNA containing sample faces three temperature phases alternatively. These phases are known as denaturation, annealing, and elongation/extension which in this study -regarding the type of the primers and the target DNA sequence- are set to occur at 95, 58, and 72 degrees of Celsius. In this study, a PCR device has been designed and fabricated which uses radiation and convection heat transfer at the same time to set and control the mentioned thermal sections. A 300W incandescent light bulb able to immediately turn off and on along with two 8×8 cm DC fans, controlled by a microcontroller as well as PID and PD controller codes are used to monitor the applied thermal cycles. In designing the controller codes it has been concerned that they not only control the temperature over the set-points as well as possible, but also increase the temperature variation rate between each two phases. The temperature data were plotted and DNA samples were used to assess the device function.

  1. U-turn type continuous irradiation method and device for radiation-irradiated capsule

    International Nuclear Information System (INIS)

    Kikuchi, Takayuki.

    1997-01-01

    A capsule to be irradiated is moved while being rotated in one of conveying shafts disposed in a reactor to conduct irradiation treatment. Then, the irradiated capsule is made U-turn in the reactor, inserted to the other conveying shaft and moved while being rotated to conduct irradiation treatment again, and then transported out of the reactor. The device comprises a rotational conveying shaft for moving the irradiated capsule while rotating it, a conveying gear for U-turning the irradiated capsule in the reactor and inserting it to the conveying shaft and a driving mechanism for synchronously rotating the conveying gear relative to the conveying shaft at a constant ratio. Mechanical time loss and manual operation time loss can be reduced upon loading and taking up of the irradiated capsule. Then, the amount of irradiation treatment per unit time is increased, and an optional neutron irradiation amount can be obtained thereby enabling to reduce operator's radiation exposure. (N.H.)

  2. Pulse X-radiation in flaw detection

    International Nuclear Information System (INIS)

    Vavilov, S.P.; Gorbunov, V.I.

    1985-01-01

    Principles of physical and engineering application of pulse X-radiation (PXR) of micro- and nanosecond duration for nondestructive testing of processes, materials and devices are given. Methods and devices, aimed at generating X-ray pulses, as well as their radiation and flow detection characteristics, and testing methods by means of PXR are considered

  3. Application of solid dosimeter to radiation control

    International Nuclear Information System (INIS)

    Tsujimoto, Tadashi

    1988-01-01

    Individual exposure dose measuring devices are used to measure the dose of each person in facilities using radiations. Major devices of this type currently used in Japan include the film badge, thermoluminescence dosimeter, portable radiation dosimeter and fluorescent glass dosimeter. All of these devices except the portable radiation dosimeter are of a solid type. Various portable-type spatial dose rate measuring devices, generally called survey meters, are available to determine the spatial distribution of radiations. Major survey meters incorporates an ionization chamber, GM counter tube or scintillation counter, while BF 3 counting tubes are available for neutron measurement. Of these, the scintillation dosimeter is of a solid type. A new scintillation survey meter has recently been developed which incorporated a discrimination bias modulation circuit. Dosimeters incorporating an ionization chamber or a GM counter tube are generally used as portable alarms. Recently, a new solid-type alarm has been developed which incorporates a solicon radiation detector. Microcomputers are also used for self-diagnosis, data processing, automatic calibration, etc. (Nogami, K.)

  4. Evaluating the Efficiency of the Device in Shielding Scattered Radiation during Treatment of Carcinoma of the Penis

    Energy Technology Data Exchange (ETDEWEB)

    Gim, Yang Soo; Lee, Sun Young; Lim, Suk Gun; Gwak, Geun Tak; Park, Ju Gyeong; Lee, Seung Hoon; Hwang, Ho In; Cha, Sook Yong [Dept. of Radiation Oncology, Chonbuk National University Hoispital, Jeonju (Korea, Republic of)

    2009-03-15

    We evaluated the device that was created for maintaining the patient's setup and protecting the testicles from scattered radiation during treatment of carcinoma of the penis. The phantom testicles were made of vaseline cotton gauze and the device consisted of 5 mm of acryl box and 4 mm of lead shielding. 3 x 3 cm{sup 2}, 4 x 4 cm{sup 2}, 5 x 5 cm{sup 2}, 6 x 6 cm{sup 2}, 7 x 7 cm{sup 2} field sizes were used for this study and measurement was made at 4, 5, 6, 7, 8, 10 cm from the lower edge of the field for 10 times with lead shielding and without the shielding respectively. 200 cGy was delivered using 6 MV photons. The scatted radiation without lead shielding at 4, 5, 6, 7, 8, 10 cm from the lower edge of the field were 14.8-4.7 cGy with 3 x 3 cm{sup 2}, 15.7-5.2 cGy with 4 x 4 cm{sup 2}, 17.6-5.5 cGy with 5 x 5 cm{sup 2}, 19.9-6.6 cGy with 6 x 6 cm{sup 2}, 22.2-7.6 cGy with 7 x 7 cm{sup 2} and the measured dose without lead shielding were 7.1-2.6 cGy with 3 x 3 cm{sup 2}, 8.9-3.6 cGy with 4 x 4 cm{sup 2}, 12.3-4.8 cGy with 5 x 5 cm{sup 2}, 14.6-5.0 cGy with 6 x 6 cm{sup 2} and 21.1-6.4 cGy with 7 x 7 cm{sup 2}. As shown above, the scatted radiation decreased after using lead shielding. Depending of the range of field sizes, the resulting difference between without shielding values and with shielding values were: 7.8-1.1 cGy at 4 cm, 5.1-1.2 cGy at 5 cm, 3.8-1.1 cGy at 6 cm, 3.4-1.7 cGy at 7 cm, 2.8-1.7 cGy at 8 cm, 2.4-2.5 cGy at 9 cm and 2.1-1.8 cGy at 10 cm. In the situation as described above, the range in values depending on the distance was 7.8-1.1 cGy with 3 x 3 cm{sup 2}, 6.9-1.6 cGy with 4 x 4 cm{sup 2}, 5.3-0.8 cGy with 5 x 5 cm{sup 2}, 5.3-1.5 cGy with 6 x 6 cm{sup 2} and 1.1-1.8 cGy with 7 x 7 cm{sup 2}. Using the device we created to shield the testicles from scattered radiation during treatment of carcinoma of the penis, we have found that scattered radiation to the testicles is decreased by the phantom testicles, and by increasing the distance

  5. The reasons why the CEO of ARPANSA issued the Licence to ANSTO

    International Nuclear Information System (INIS)

    Loy, J.

    2002-01-01

    Government is proceeding with the planning for a national intermediate level waste store - there is political controversy about this as illustrated by the passage of legislation in South Australia to prevent the store being sited in that State. ANSTO's management of its lower level waste has also been undertaken with the assumption that there would be a national low level waste repository established. The issue of sabotage and terrorism has of course been a major one for assessment following the events of September 11, 2001. A very large effort has been devoted to this by ARPANSA, ANSTO and INVAP and by the relevant agencies within Australia. There has been very close examination of scenarios for attack upon the reactor and measures are to be included in the design to reduce greatly the likelihood of the success of any such attack. At the CEO's request, ANSTO did undertake an analysis of the consequences of a successful aircraft attack, that is simply assuming away all the protection and assuming the core of the reactor was fully exposed and in the midst of the fire caused by a large aircraft. This analysis and those done by ARPANSA staff shows that the radioactive contamination would be spread some distance from the reactor, but dispersed in a way that meant that the largest radiation dose to an adult member of the public would be less than that requiring action under the guidance published internationally. It is also prudent that there be emergency arrangements in place to deal with the consequences of any accident or event that resulted in release of radioactivity. The CEO required that ANSTO have an independent review of emergency arrangements before seeking any operating licence. The CEO has also assessed the viability of INVAP as an Argentinian company, in the context of the current Argentinian economic crisis by looking at the provisions of the contract between ANSTO and INVAP and reviewing information available to him about INVAP's financial viability. He indicated

  6. Device for simulation of integral dose distribution in multifield radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Belyakov, E K; Voronin, V V; Kolosova, V F; Moskalev, A I; Marova, Yu M; Stavitskii, R V; Yarovoi, V S

    1974-11-15

    Described is a device for simulation of the sum dose distribution at multifield radiation therapy; the device comprises a mechanical unit on which the emission sources and detectors are mounted, an electromechanical scanning equipment, amplifiers, an adder, a position sensor and a recording instrument. The device suggested raises an accuracy of a sick man radiation program elaboration at a remote multifield radiation therapy, permits to estimate the irradiated medium heterogeneity and beam shaper influence on the sum dose distribution and also ensured the information on the sum dose distribution of the relative or absolute units. Additional filters simulating heterogeneity and beam shaping conditions of ionizing radiation may be mounted between the quantum emission sources and detectors, and an amplifier with a variable amplification factor may be placed between the adders and printers. Thus it is possible to obtain a sum dose distribution at static methods of the remote radiation therapy at a high degree of accuracy (up to +-10%).

  7. Significantly increased detection rate of drugs of abuse in urine following the introduction of new German driving licence re-granting guidelines.

    Science.gov (United States)

    Agius, Ronald; Nadulski, Thomas; Kahl, Hans-Gerhard; Dufaux, Bertin

    2012-02-10

    In this paper we present the first assessment of the new German driving licence re-granting medical and psychological assessment (MPA) guidelines by comparing over 3500 urine samples tested under the old MPA cut-offs to over 5000 samples tested under the new MPA cut-offs. Since the enzyme multiplied immunoassay technique (EMIT) technology used previously was not sensitive enough to screen for drugs at such low concentrations, as suggested by the new MPA guidelines, enzyme-linked immunosorbent assay (ELISA) screening kits were used to screen for the drugs of abuse at the new MPA cut-offs. The above comparison revealed significantly increased detection rates of drug use or exposure during the rehabilitation period as follows: 1.61, 2.33, 3.33, and 7 times higher for 11-nor-delta-9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH), morphine, benzoylecgonine and amphetamine respectively. The present MPA guidelines seem to be more effective to detect non-abstinence from drugs of abuse and hence to detecting drivers who do not yet fulfil the MPA requirements to regain their revoked driving licence. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  8. Radiation detector system having heat pipe based cooling

    Science.gov (United States)

    Iwanczyk, Jan S.; Saveliev, Valeri D.; Barkan, Shaul

    2006-10-31

    A radiation detector system having a heat pipe based cooling. The radiation detector system includes a radiation detector thermally coupled to a thermo electric cooler (TEC). The TEC cools down the radiation detector, whereby heat is generated by the TEC. A heat removal device dissipates the heat generated by the TEC to surrounding environment. A heat pipe has a first end thermally coupled to the TEC to receive the heat generated by the TEC, and a second end thermally coupled to the heat removal device. The heat pipe transfers the heat generated by the TEC from the first end to the second end to be removed by the heat removal device.

  9. X-ray face mask and bib device

    International Nuclear Information System (INIS)

    Forshee, D.J.; Moti, S.

    1984-01-01

    This invention provides an improved device for shielding and protecting a person against direct and scattered x-ray radiation to the face, head and neck to be worn on the shoulders. The device includes a radiation-shielding face mask having a lead-filled frame and a lead-containing transparent radiation-shielding lens mounted in the frame. The frame is supported upon the shoulders. A first portion of the frame extends generally inward below the chin of the person, and a second portion of the frame extends generally vertically from an inward portion of the first portion and generally rearwardly adjacent to at least one lateral side of the neck of the person

  10. MO-C-BRB-05: Translating NIH funding to a [potential] clinical device in breast cancer radiation therapy

    International Nuclear Information System (INIS)

    Yu, C.

    2015-01-01

    Diagnostic radiology and radiation oncology are arguably two of the most technologically advanced specialties in medicine. The imaging and radiation medicine technologies in clinical use today have been continuously improved through new advances made in the commercial and academic research arenas. This symposium explores the translational path from research through clinical implementation. Dr. Pettigrew will start this discussion by sharing his perspectives as director of the National Institute of Biomedical Imaging and Bioengineering (NIBIB). The NIBIB has focused on promoting research that is technological in nature and has high clinical impact. We are in the age of precision medicine, and the technological innovations and quantitative tools developed by engineers and physicists working with physicians are providing innovative tools that increase precision and improve outcomes in health care. NIBIB funded grants lead to a very high patenting rate (per grant dollar), and these patents have higher citation rates by other patents, suggesting greater clinical impact, as well. Two examples of clinical translation resulting from NIH-funded research will be presented, in radiation therapy and diagnostic imaging. Dr. Yu will describe a stereotactic radiotherapy device developed in his laboratory that is designed for treating breast cancer with the patient in the prone position. It uses 36 rotating Cobalt-60 sources positioned in an annular geometry to focus the radiation beam at the system’s isocenter. The radiation dose is delivered throughout the target volume in the breast by constantly moving the patient in a planned trajectory relative to the fixed isocenter. With this technique, the focal spot dynamically paints the dose distribution throughout the target volume in three dimensions. Dr. Jackson will conclude this symposium by describing the RSNA Quantitative Imaging Biomarkers Alliance (QIBA), which is funded in part by NIBIB and is a synergistic collaboration

  11. MO-C-BRB-05: Translating NIH funding to a [potential] clinical device in breast cancer radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Yu, C. [Univ Maryland School of Medicine (United States)

    2015-06-15

    Diagnostic radiology and radiation oncology are arguably two of the most technologically advanced specialties in medicine. The imaging and radiation medicine technologies in clinical use today have been continuously improved through new advances made in the commercial and academic research arenas. This symposium explores the translational path from research through clinical implementation. Dr. Pettigrew will start this discussion by sharing his perspectives as director of the National Institute of Biomedical Imaging and Bioengineering (NIBIB). The NIBIB has focused on promoting research that is technological in nature and has high clinical impact. We are in the age of precision medicine, and the technological innovations and quantitative tools developed by engineers and physicists working with physicians are providing innovative tools that increase precision and improve outcomes in health care. NIBIB funded grants lead to a very high patenting rate (per grant dollar), and these patents have higher citation rates by other patents, suggesting greater clinical impact, as well. Two examples of clinical translation resulting from NIH-funded research will be presented, in radiation therapy and diagnostic imaging. Dr. Yu will describe a stereotactic radiotherapy device developed in his laboratory that is designed for treating breast cancer with the patient in the prone position. It uses 36 rotating Cobalt-60 sources positioned in an annular geometry to focus the radiation beam at the system’s isocenter. The radiation dose is delivered throughout the target volume in the breast by constantly moving the patient in a planned trajectory relative to the fixed isocenter. With this technique, the focal spot dynamically paints the dose distribution throughout the target volume in three dimensions. Dr. Jackson will conclude this symposium by describing the RSNA Quantitative Imaging Biomarkers Alliance (QIBA), which is funded in part by NIBIB and is a synergistic collaboration

  12. Type testing of devices with inserted radioactive sources

    International Nuclear Information System (INIS)

    Rolle, A.; Droste, B.; Dombrowski, H.

    2006-01-01

    In Germany devices with inserted radioactive sources can get a type approval if they comply with specific requirements. Whoever operates a device whose type has been approved in accordance with the German Radiation Protection Ordinance does not need an individual authorization. Such type approvals for free use are granted by the Federal Office for Radiation Protection (B.f.S.) on the basis of type testing performed by the Physikalisch-Technische Bundesanstalt (P.T.B.), the national metrology institute, and the Bundesanstalt fur Materialforschung und -prufung (B.A.M.), the Federal Institute for Materials Research and Testing. Main aspects of the assessment are the activity of the radioactive sources, the dose equivalent rate near the devices, the tamper-proofness and leak-tightness of the sources and the safety of the construction of the devices. With the new Radiation Protection Ordinance in 2001, more stringent requirements for a type approval were established. Experiences with the new regulations and the relevant assessment criteria applied by P.T.B. and B.A.M. will be presented. (authors)

  13. Radiation protection and regulatory aspects in the use of radiation sources

    International Nuclear Information System (INIS)

    Sen, Amit; Dash Sharma, P.K.; Sonawane, A.U.

    2012-01-01

    The uses of ionising radiation sources (i.e. radioisotopes and radiation generating equipment such as accelerators and X-ray machines) for multifarious applications in industry, medicine, agriculture, research and teaching have been significantly increasing all over the world. In India, the application of radiation sources in various fields has registered phenomenal growth during the last decade. The use of radiation sources mainly include radiation processing for food preservation and sterilization of healthcare products, radiotherapy for treatment of cancer, nuclear medicine for diagnosis and therapy, gamma chambers for several R and D studies, blood irradiators, industrial radiography for non destructive examinations of steel structures, industrial ionising radiation gauging devices for monitoring/measurement of on-line quality control parameters (e.g. thickness, level, density, moisture, elemental analysis), consumer products such as gaseous tritium light sources (GTLS), gaseous tritium light devices (GTLD), ionisation chamber smoke detectors (ICSD), fluorescent light starters, antistatic devices and incandescent gas mantles containing thorium etc. All these beneficial applications involve use of both sealed and unsealed radioactive sources and amount of radioactivity varies from few kBq (μCi) to hundreds of TBq (thousands of curies). Radiation sources emit ionising radiations and if not handled properly and safely, may give rise to potential exposures leading to an unacceptable hazard. Therefore, it is necessary to ensure a high standard of safety and reliability in handling of radiation equipment and sources through their careful design by ensuring adequate built-in-safety as per applicable national/international standard, safe operation and periodic maintenance procedures, safe transport from one place to another, secured storage when not in use, physical security to radiation sources, effective emergency response plans and preparedness, including safe

  14. Spectroradiometer Intercomparison and Impact on Characterizing Photovoltaic Device Performance: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Habte, A.; Andreas, A.; Ottoson, L.; Gueymard, C.; Fedor, G.; Fowler, S.; Peterson, J.; Naranen, E.; Kobashi, T.; Akiyama, A.; Takagi, S.

    2014-11-01

    Indoor and outdoor testing of photovoltaic (PV) device performance requires the use of solar simulators and natural solar radiation, respectively. This performance characterization requires accurate knowledge of spectral irradiance distribution that is incident on the devices. Spectroradiometers are used to measure the spectral distribution of solar simulators and solar radiation. On September 17, 2013, a global spectral irradiance intercomparison using spectroradiometers was organized by the Solar Radiation Research Laboratory (SRRL) at the National Renewable Energy Laboratory (NREL). This paper presents highlights of the results of this first intercomparison, which will help to decrease systematic inter-laboratory differences in the measurements of the outputs or efficiencies of PV devices and harmonize laboratory experimental procedures.

  15. Positioning devices for patients

    International Nuclear Information System (INIS)

    Heavens, M.

    1981-01-01

    It has been suggested that it is very important to position patients reproducibly at different stages of radiotherapy treatment planning and treatment, or similar procedures. Devices have been described for positioning a patient's upper and lower thorax. This invention provides reproducible positioning for a female patient's breasts, for example in planning treatment of and treating breast tumours. The patient is placed prone, using for example an upper thorax device. A support device is placed central to and beneath her breasts to partially displace them outwards. The device may be triangular in section with one apex contacting the chest wall at the sternum. Restraining straps may be provided to hold the breasts against the support device. Means may be provided to take a healthy breast from the path of radiation through the tumour. (author)

  16. Resistive Memory Devices for Radiation Resistant Non-Volatile Memory

    Data.gov (United States)

    National Aeronautics and Space Administration — Ionizing radiation in space can damage electronic equipment, corrupting data and even disabling computers. Radiation resistant (rad hard) strategies must be employed...

  17. Basic mechanisms of radiation effects on electronic materials and devices

    International Nuclear Information System (INIS)

    Winokur, P.S.

    1989-01-01

    Many defense and nuclear reactor systems require complementary metal-oxide semiconductor integrated circuits that are tolerant to high levels of radiation. This radiation can result from space, hostile environments or nuclear reactor and accelerator beam environments. In addition, many techniques used to fabricate today's complex very-large-scale integration circuits expose the circuits to ionizing radiation during the process sequence. Whatever its origin, radiation can cause significant damage to integrated-circuit materials. This damage can lead to circuit performance degradation, logic upset, and even catastrophic circuit failure. This paper provides a brief overview of the basic mechanisms for radiation damage to silicon-based integrated circuits. Primary emphasis is on the effects of total-dose ionizing radiation on metal-oxide-semiconductor (MOS) structures

  18. Education and training in radiation protection in Morocco: experiences and perspectives

    Energy Technology Data Exchange (ETDEWEB)

    El Messaoudi, M.; Essadki, H.; Lferde, M.; Moutia, Z. [Faculte des Sciences, Dept. de Physique, Rabat (Morocco)

    2006-07-01

    Education and training are of primary importance for achieving competence in radiation protection. Unfortunately, one records the absence of a national legislation specifying the training of the qualified expert. On the basis of the observation which there exists in the Faculties of Sciences of Morocco the courses in radiation protection within the framework of preparation of the D.E.S.A;/M.A.S.T.E.R., we will propose to create a master in radiation protection within the framework of the reform of the higher education in progress. This reform proposes three levels: licence, Master, Ph.D. According to the B.S.S., any person who is occupationally exposed to ionising radiation or who may be exposed in the course of the work should receive adequate training in radiation protection. The Nuclear Physics Laboratory of Rabat (N.P.L.R.) has participated in the organisation of IAEA postgraduate educational and training courses in radiation protection and the safety of radiation sources since 1998. It is also pioneer in the preparation of the doctorate thesis in radiation protection. The objective of this work is to present the important points of national strategy for building competence in radiation protection and the role of Radiation Protection Group(R.P.D.), created recently at our Physics department, to ensure the organisation of a radiation protection master. (authors)

  19. Education and training in radiation protection in Morocco: experiences and perspectives

    International Nuclear Information System (INIS)

    El Messaoudi, M.; Essadki, H.; Lferde, M.; Moutia, Z.

    2006-01-01

    Education and training are of primary importance for achieving competence in radiation protection. Unfortunately, one records the absence of a national legislation specifying the training of the qualified expert. On the basis of the observation which there exists in the Faculties of Sciences of Morocco the courses in radiation protection within the framework of preparation of the D.E.S.A;/M.A.S.T.E.R., we will propose to create a master in radiation protection within the framework of the reform of the higher education in progress. This reform proposes three levels: licence, Master, Ph.D. According to the B.S.S., any person who is occupationally exposed to ionising radiation or who may be exposed in the course of the work should receive adequate training in radiation protection. The Nuclear Physics Laboratory of Rabat (N.P.L.R.) has participated in the organisation of IAEA postgraduate educational and training courses in radiation protection and the safety of radiation sources since 1998. It is also pioneer in the preparation of the doctorate thesis in radiation protection. The objective of this work is to present the important points of national strategy for building competence in radiation protection and the role of Radiation Protection Group(R.P.D.), created recently at our Physics department, to ensure the organisation of a radiation protection master. (authors)

  20. Evaluation of novel disposable, light-weight radiation protection devices in an interventional radiology setting: a randomized controlled trial.

    Science.gov (United States)

    Uthoff, Heiko; Peña, Constantino; West, James; Contreras, Francisco; Benenati, James F; Katzen, Barry T

    2013-04-01

    Radiation exposure to interventionalists is increasing. The currently available standard radiation protection devices are heavy and do not protect the head of the operator. The aim of this study was to evaluate the effectiveness and comfort of caps and thyroid collars made of a disposable, light-weight, lead-free material (XPF) for occupational radiation protection in a clinical setting. Up to two interventional operators were randomized to wear a XPF or standard 0.5-mm lead-equivalent thyroid collars in 60 consecutive endovascular procedures requiring fluoroscopy. Simultaneously a XPF cap was worn by all operators. Radiation doses were measured using dosimeters placed outside and underneath the caps and thyroid collars. Wearing comfort was assessed at the end of each procedure on a visual analog scale (0-100 [100 = optimal]). Patient and procedure data did not differ between the XPF and standard protection groups. The cumulative radiation dose measured outside the cap was 15,700 μSv and outside the thyroid collars 21,240 μSv. Measured radiation attenuation provided by the XPF caps (n = 70), XPF thyroid collars (n = 40), and standard thyroid collars (n = 38) was 85.4% ± 25.6%, 79.7% ± 25.8% and 71.9% ± 34.2%, respectively (mean difference XPF vs standard thyroid collars, 7.8% [95% CI, -5.9% to 21.6%]; p = 0.258). The median XPF cap weight was 144 g (interquartile range, 128-170 g), and the XPF thyroid collars were 27% lighter than the standard thyroid collars (p disposable caps and thyroid collars made of XPF were assessed as being comfortable to wear, and they provide radiation protection similar to that of standard 0.5-mm lead-equivalent thyroid collars.

  1. Giant magneto-resistance devices

    CERN Document Server

    Hirota, Eiichi; Inomata, Koichiro

    2002-01-01

    This book deals with the application of giant magneto-resistance (GMR) effects to electronic devices. It will appeal to engineers and graduate students in the fields of electronic devices and materials. The main subjects are magnetic sensors with high resolution and magnetic read heads with high sensitivity, required for hard-disk drives with recording densities of several gigabytes. Another important subject is novel magnetic random-access memories (MRAM) with non-volatile non-destructive and radiation-resistant characteristics. Other topics include future GMR devices based on bipolar spin transistors, spin field-effect transistors (FETs) and double-tunnel junctions.

  2. Radiation Control Act 1977 - No 66 of 1977

    International Nuclear Information System (INIS)

    1977-01-01

    This Act regulates the use of radioactive materials and radiation-emitting devices. It sets up a Radiation Advisory Council to advise the competent authorities on questions within the scope of the Act, also with a view to radiation protection. The Act also lays down a licensing system for such materials and devices. The Radioactive Substances Acts 1954 and 1966 are repealed. (NEA) [fr

  3. Infrared thermal annealing device

    International Nuclear Information System (INIS)

    Gladys, M.J.; Clarke, I.; O'Connor, D.J.

    2003-01-01

    A device for annealing samples within an ultrahigh vacuum (UHV) scanning tunneling microscopy system was designed, constructed, and tested. The device is based on illuminating the sample with infrared radiation from outside the UHV chamber with a tungsten projector bulb. The apparatus uses an elliptical mirror to focus the beam through a sapphire viewport for low absorption. Experiments were conducted on clean Pd(100) and annealing temperatures in excess of 1000 K were easily reached

  4. Proton irradiation effects on gallium nitride-based devices

    Science.gov (United States)

    Karmarkar, Aditya P.

    Proton radiation effects on state-of-the-art gallium nitride-based devices were studied using Schottky diodes and high electron-mobility transistors. The device degradation was studied over a wide range of proton fluences. This study allowed for a correlation between proton irradiation effects between different types of devices and enhanced the understanding of the mechanisms responsible for radiation damage in GaN-based devices. Proton irradiation causes reduced carrier concentration and increased series resistance and ideality factor in Schottky diodes. 1.0-MeV protons cause greater degradation than 1.8-MeV protons because of their higher non-ionizing energy loss. The displacement damage in Schottky diodes recovers during annealing. High electron-mobility transistors exhibit extremely high radiation tolerance, continuing to perform up to a fluence of ˜1014 cm-2 of 1.8-MeV protons. Proton irradiation creates defect complexes in the thin-film structure. Decreased sheet carrier mobility due to increased carrier scattering and decreased sheet carrier density due to carrier removal by the defect centers are the primary damage mechanisms. Interface disorder at either the Schottky or the Ohmic contact plays a relatively unimportant part in overall device degradation in both Schottky diodes and high electron-mobility transistors.

  5. A simple quality assurance test tool for the visual verification of light and radiation field congruent using electronic portal images device and computed radiography

    International Nuclear Information System (INIS)

    Njeh, Christopher F; Caroprese, Blas; Desai, Pushkar

    2012-01-01

    The radiation field on most megavoltage radiation therapy units are shown by a light field projected through the collimator by a light source mounted inside the collimator. The light field is traditionally used for patient alignment. Hence it is imperative that the light field is congruent with the radiation field. A simple quality assurance tool has been designed for rapid and simple test of the light field and radiation field using electronic portal images device (EPID) or computed radiography (CR). We tested this QA tool using Varian PortalVision and Elekta iViewGT EPID systems and Kodak CR system. Both the single and double exposure techniques were evaluated, with double exposure technique providing a better visualization of the light-radiation field markers. The light and radiation congruency could be detected within 1 mm. This will satisfy the American Association of Physicists in Medicine task group report number 142 recommendation of 2 mm tolerance. The QA tool can be used with either an EPID or CR to provide a simple and rapid method to verify light and radiation field congruence

  6. Radiation monitoring system for astronauts

    International Nuclear Information System (INIS)

    Thomson, I.; MacKay, G.; Ng, A.; Tomi, L.

    1996-01-01

    Astronauts in space are constantly under the bombardment of radiation particles from trapped electrons, and trapped proton. In addition, cosmic rays, while penetrating the spacecraft shell, generate secondary radiation of neutrons. As astronauts' stay in space is getting longer, the need for a real-time radiation monitoring device has become critical. Thermoluminescent dosemeter (TLD), used onboard both the MIR and the Space Transportation System (STS), cannot provide real-time dose reading. This paper describes a real-time direct read-out device, currently under development, which can measure skin, eye, and Blood Forming Organ (BFO) doses separately. (author)

  7. The moisture content monitoring device for PuO2 using self neutron radiation

    International Nuclear Information System (INIS)

    Bulanenko, Valeriy I.; Sviridov, Victor; Frolov, Vladimir V.; Ryazanov, Boris G.; Talanov, Vladimir V.

    2003-01-01

    Solutions technology of plutonium dioxide powders production inevitably leads to free or chemically bound hydrogen to be present in these powders. This work is devoted to the nondestructive method of PuO 2 powder moisture measurement based on application of the effect of neutron moderation caused by water. Plutonium dioxide is fast neutron source, while 3 He counters located in the nickel and polyethylene annular reflectors surrounding PuO 2 serve as detectors. In the work wide range of issues are considered related to practical implementation of the moisture measurement method by detecting inherent neutron radiation of plutonium dioxide powder. The most practical design of the detector has been chosen, which include two 3 He detectors having different reflectors mounted to the device. The absolute error of measurement does not exceed 0.2wt% with confidence coefficient of 0.95. Duration of analysis ∼5 minutes. (author)

  8. Radiation terrorism: what society needs from the radiobiology-radiation protection and radiation oncology communities

    International Nuclear Information System (INIS)

    Coleman, C Norman; Parker, Gerald W

    2009-01-01

    Society's and individuals' concerns about the adverse effects from radiation are logically amplified many times when radiological terrorism is considered. The spectrum of events include industrial sabotage, the use of an explosive or non-explosive radiological dispersal device, the placement of a radiological exposure device in a public facility and the use of an improvised nuclear device. The consequences of an event relate to the physical and medical damage of the event itself, the financial impact, and the acute and long-term medical consequences, including fear of radiation-induced cancer. The magnitude of a state-sponsored nuclear event is so great that limited detailed response planning had been done in the past, as compared to the work now ongoing. Planning is done on the basis of scenario modelling. Medical response planning includes medical triage, distribution of victims to care by experienced physicians, developing medical countermeasures to mitigate or treat radiation injury, counselling and appropriately following exposed or potentially exposed people, and helping the local community develop confidence in their own response plan. Optimal response must be based on the best available science. This requires scientists who can define, prioritise and address the gaps in knowledge with the range of expertise from basic physics to biology to translational research to systems expertise to response planning to healthcare policy to communications. Not only are there unique needs and career opportunities, but there is also the opportunity for individuals to serve their communities and country with education regarding radiation effects and by formulating scientifically based government policy.

  9. Radiation terrorism: what society needs from the radiobiology-radiation protection and radiation oncology communities

    Energy Technology Data Exchange (ETDEWEB)

    Coleman, C Norman [Office of Preparedness and Emergency Response, Office of the Assistant Secretary for Preparedness and Response, Department of Health and Human Services, Washington, DC (United States); Parker, Gerald W [Office of the Assistant Secretary for Preparedness and Response, Department of Health and Human Services, Washington, DC (United States)

    2009-06-01

    Society's and individuals' concerns about the adverse effects from radiation are logically amplified many times when radiological terrorism is considered. The spectrum of events include industrial sabotage, the use of an explosive or non-explosive radiological dispersal device, the placement of a radiological exposure device in a public facility and the use of an improvised nuclear device. The consequences of an event relate to the physical and medical damage of the event itself, the financial impact, and the acute and long-term medical consequences, including fear of radiation-induced cancer. The magnitude of a state-sponsored nuclear event is so great that limited detailed response planning had been done in the past, as compared to the work now ongoing. Planning is done on the basis of scenario modelling. Medical response planning includes medical triage, distribution of victims to care by experienced physicians, developing medical countermeasures to mitigate or treat radiation injury, counselling and appropriately following exposed or potentially exposed people, and helping the local community develop confidence in their own response plan. Optimal response must be based on the best available science. This requires scientists who can define, prioritise and address the gaps in knowledge with the range of expertise from basic physics to biology to translational research to systems expertise to response planning to healthcare policy to communications. Not only are there unique needs and career opportunities, but there is also the opportunity for individuals to serve their communities and country with education regarding radiation effects and by formulating scientifically based government policy.

  10. Radioactive gas waste processing device

    International Nuclear Information System (INIS)

    Soma, Koichi.

    1996-01-01

    The present invention concerns a radioactive gas waste processing device which extracts exhaust gases from a turbine condensator in a BWR type reactor and releases them after decaying radioactivity thereof during temporary storage. The turbine condensator is connected with an extracting ejector, a preheater, a recombiner for converting hydrogen gas into steams, an off gas condensator for removing water content, a flow rate control valve, a dehumidifier, a hold up device for removing radiation contaminated materials, a vacuum pump for sucking radiation decayed-off gases, a circulation water tank for final purification and an exhaustion cylinder by way of connection pipelines in this order. An exhaust gas circulation pipeline is disposed to circulate exhaust gases from an exhaust gas exit pipeline of the recycling water tank to an exhaust gas exit pipeline of the exhaust gas condensator, and a pressure control valve is disposed to the exhaust gas circulation pipeline. This enable to perform a system test for the dehumidification device under a test condition approximate to the load of the dehumidification device under actual operation state, and stabilize both of system flow rate and pressure. (T.M.)

  11. Minimising radiation exposure due to source assembly-related deficiencies in industrial gamma radiography exposure devices (IGREDs)

    International Nuclear Information System (INIS)

    Sivaraman, G.; Kannan, R.; Nandakumar, A.N.; Subrahmanya, M.J.; Murthy, B.K.S.

    2000-01-01

    Industrial radiographers receive higher doses as compared to radiation workers in medicine, agriculture, research, etc. Hence, it is essential that industrial gamma radiography exposure device (IGRED) be provided with efficient and effective safety systems in their design and operation to ensure smooth operation and minimise radiation exposures to the operators and public. Even though all these exposure devices have undergone stringent tests for radiographic exposure devices under international or national standards, certain deficiencies were noticed when scientists of Radiological Physics and Advisory Division (RPAD), carried out radiography equipment inspection of IGREDs. Some examples are briefly described here. The use of depleted Uranium pencil in some models led to the source pencil getting jammed due to formation of Uranium Oxide and bulging of the pencil. The solution was to replace the uranium pencil with high quality tungsten pencils or stainless steel clad pencils. In one type of pencils the source assembly would flare up after some use obstructing the smooth movement of the source assembly. The suggestion to subject the source assemblies to heat treatment solved the problem. In another type, the source pencil was getting corroded in high humid condition and affected the source movement. When the composition of the source pencil was changed it could withstand high humid condition. Another model had a hook type coupling between source assembly and drive cable. This often resulted in disengagement of the source assembly from the drive cable. Suggestions were made to change the coupling to ball and socket coupling for smooth functioning and for 'fail-safe' operation. During early days of the use of remote operated IGRED, in one particular model of the IGRED, the Iridium source wafers were directly loaded in a single encapsulation. Once the welding gave way and the source wafers got strewn. Subsequently, the source pellets/wafers were doubly encapsulated

  12. Portable Integrated Wireless Device Threat Assessment to Aircraft Radio Systems

    Science.gov (United States)

    Salud, Maria Theresa P.; Williams, Reuben A. (Technical Monitor)

    2004-01-01

    An assessment was conducted on multiple wireless local area network (WLAN) devices using the three wireless standards for spurious radiated emissions to determine their threat to aircraft radio navigation systems. The measurement process, data and analysis are provided for devices tested using IEEE 802.11a, IEEE 802.11b, and Bluetooth as well as data from portable laptops/tablet PCs and PDAs (grouping known as PEDs). A comparison was made between wireless LAN devices and portable electronic devices. Spurious radiated emissions were investigated in the radio frequency bands for the following aircraft systems: Instrument Landing System Localizer and Glideslope, Very High Frequency (VHF) Communication, VHF Omnidirectional Range, Traffic Collision Avoidance System, Air Traffic Control Radar Beacon System, Microwave Landing System and Global Positioning System. Since several of the contiguous navigation systems were grouped under one encompassing measurement frequency band, there were five measurement frequency bands where spurious radiated emissions data were collected for the PEDs and WLAN devices. The report also provides a comparison between emissions data and regulatory emission limit.

  13. Comparison of noise power spectrum methodologies in measurements by using various electronic portal imaging devices in radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Son, Soon Yong [Dept. of Radiological Technology, Wonkwang Health Science University, Iksan (Korea, Republic of); Choi, Kwan Woo [Dept. of Radiology, Asan Medical Center, Seoul (Korea, Republic of); Jeong, Hoi Woun [Dept. of Radiological Technology, Baekseok Culture University College, Cheonan (Korea, Republic of); Kwon, Kyung Tae [Dep. of Radiological Technology, Dongnam Health University, Suwon (Korea, Republic of); Kim, Ki Won [Dept. of Radiology, Kyung Hee University Hospital at Gang-dong, Seoul (Korea, Republic of); Lee, Young Ah; Son, Jin Hyun; Min, Jung Whan [Shingu University College, Sungnam (Korea, Republic of)

    2016-03-15

    The noise power spectrum (NPS) is one of the most general methods for measuring the noise amplitude and the quality of an image acquired from a uniform radiation field. The purpose of this study was to compare different NPS methodologies by using megavoltage X-ray energies. The NPS evaluation methods in diagnostic radiation were applied to therapy using the International Electro-technical Commission standard (IEC 62220-1). Various radiation therapy (RT) devices such as TrueBeamTM(Varian), BEAMVIEWPLUS(Siemens), iViewGT(Elekta) and ClinacR iX (Varian) were used. In order to measure the region of interest (ROI) of the NPS, we used the following four factors: the overlapping impact, the non-overlapping impact, the flatness and penumbra. As for NPS results, iViewGT(Elekta) had the higher amplitude of noise, compared to BEAMVIEWPLUS (Siemens), TrueBeamTM(Varian) flattening filter, ClinacRiXaS1000(Varian) and TrueBeamTM(Varian) flattening filter free. The present study revealed that various factors could be employed to produce megavoltage imaging (MVI) of the NPS and as a baseline standard for NPS methodologies control in MVI.

  14. Radiation-hardened gate-around n-MOSFET structure for radiation-tolerant application-specific integrated circuits

    International Nuclear Information System (INIS)

    Lee, Min Su; Lee, Hee Chul

    2012-01-01

    To overcome the total ionizing dose effect on an n-type metal-oxide-semiconductor field-effect transistor (n-MOSFET), we designed a radiation-hardened gate-around n-MOSFET structure and evaluated it through a radiation-exposure experiment. Each test device was fabricated in a commercial 0.35-micron complementary metal-oxide-semiconductor (CMOS) process. The fabricated devices were evaluated under a total dose of 1 Mrad (Si) at a dose rate of 250 krad/h to obtain very high reliability for space electronics. The experimental results showed that the gate-around n-MOSFET structure had very good performance against 1 Mrad (Si) of gamma radiation, while the conventional n-MOSFET experienced a considerable amount of radiation-induced leakage current. Furthermore, a source follower designed with the gate-around transistor worked properly at 1 Mrad (Si) of gamma radiation while a source follower designed with the conventional n-MOSFET lost its functionality.

  15. Decree No 85/9727 of 24/7/1985 on radiation safety regulation

    International Nuclear Information System (INIS)

    1985-01-01

    This Decree took effect on 7 September 1985 and revises Decree No. 7/9038 of 30 November 1974. It was prepared on the basis of recommendation No. 26 of the International Commission on Radiological Protection (ICRP). Its purpose is to provide protection for persons against ionizing radiations arising from the medical, industrial, research and other applications of nuclear energy. According to its provisions, all persons and establishments which keep, use, produce or store radioactive materials and radiation sources must obtain a licence from the Turkish Atomic Energy Authority (TAEA). In addition, the import, export and transport of all radioactive materials must be approved by TAEA and a valid permit issued by TAEA must be presented to customs authorities for all importation and exportation. (NEA) [fr

  16. Computer simulation of ionizing radiation burnout in power MOSFETs

    International Nuclear Information System (INIS)

    Keshavarz, A.A.; Fischer, T.A.; Dawes, W.R. Jr.; Hawkins, C.F.

    1988-01-01

    The transient response of a power MOSFET device to ionizing radiation was examined using the BAMBI device simulator. The radiation rate threshold for burnout was determined for several different cases. The burnout mechanism was attributed to current-induced avalanche. The effects of the applied drain-source voltage and the base width of the parasitic bipolar device on the threshold level were modeled. It was found that the radiation rate threshold is lower at higher drain-source voltages or narrower bases. 8 refs., 17 figs

  17. Micropole undulators: Novel insertion devices for synchrotron sources

    International Nuclear Information System (INIS)

    Toor, A.; Csonka, P.; Tatchyn, R.

    1989-01-01

    Micropole undulators (wigglers) are undulators (wigglers) with submillimeter periods and are referred to, generically, as micropole insertion devices. Compared to ordinary insertion devices, whose period λ u is typically ≥l cm, micropole devices have periods smaller by a factor f≤10. Therefore, the first-harmonic radiation emitted by a micropole undulator will have its photon energy E γ increased by f and its spectral purity Δλ/λ by f, provided the total length of the undulator l u stays unchanged, and magnetic field errors, as well as the electron-beam emittance, are sufficiently small. Furthermore, to generate photons of the same E γ as from the conventional device, the electron-beam energy E e can be reduced by f 1/2 , resulting in significantly lower construction and operating costs. Radiative energy losses can be correspondingly diminished for the associated storage rings. In this paper we report on results recently obtained by us in the practical implementation and design of micropole undulators at the Stanford Synchrotron Radiation Laboratory (SSRL) and the Lawrence Livermore National Laboratory (LLNL). Based on our work, micropole undulators with f≤10 4 appear feasible at the present time

  18. Sterilization by ionizing radiation comparative evaluation

    International Nuclear Information System (INIS)

    Tata, A.; Giuliani, S.

    1996-01-01

    Sterilization of surgical and medical devices by ionizing radiation (gamma or accelerated electron beams) is currently regarded as one of the main industrial-scale applications of radiation technology processes. Considering the most widely utilized chemical-physical methods (i.e. ethylene oxide (EtO) fumigation and radiation treatment), about 10-12 millions m(3) of surgical and medical devices are estimated to be processed yearly all around the world, of which 7 on beams. Due to the increasing demand for reusable and single-use devices, and the need of assuring their sterility in order to prevent, as much as possible, the diffusion of serious infective diseases (among which for instance Aids), the market of sterilization of these items is considerably expanding. In the general depicted scenario, radiation technologies are expected to gain a leading role, even a part from their economic attractiveness, as an alternative to EtO treatment, which is more and more considered as responsible for increasing environmental, social and public health problems

  19. Radiation monitoring system

    International Nuclear Information System (INIS)

    Takeuchi, Nobuyoshi; Fujimoto, Toshiaki; Nagama, Hideyo

    2007-01-01

    A positive outlook toward nuclear power plants and a higher level of technologies for using radiation in the medical field are trends that are spreading throughout the world, and as a consequence, demand is increasing for equipment and systems that measure and control radiation. Equipment ranging from radiation detection and measurement devices to computer-based radiation management systems will be set up in overseas. Products that depend on overseas specifications based on IEC and other international standards are being developed. Fuji Electric is advancing the overseas deployment of radiation monitoring systems by adopting measures that will ensure the reliability and traceability of radiation equipment. (author)

  20. Evaluation of manufactured device for radiation therapy in head and neck cancer

    International Nuclear Information System (INIS)

    Kim, Tae Jun; Jin, Sun Sik; Kim, Dong Wook; Chung, Weon Kuu; Kim, Kyoung Tae

    2014-01-01

    We compared the set-up accuracy and right-left shoulder position variation of the manufactured device and other commercial shoulder-retractors in the head and neck radiation treatment. Six patients consist of three groups which were used three different Shoulder retractors. We measured position corrections of left and right Shoulder and the couch after the image guidance by using on board imager (OBI) for six head and neck patients who has the extended target to the neck node lower region. The position variation correction of left (right) Shoulder after image guidance were 1.07±3.99 mm (-4.35±2.09 mm), -0.37±5.91 mm (1.26±5.28 mm), -0.63±2.44 mm (0.25±1.61 mm) for group A, B and C. The vertical, lateral, longitudinal position and angular corrections of the couch after image guidance were -2.06±2.68, -1.11±8.15, 0.34±3.78 mm, and 0.51 ±0.77 degree for group A, -1.18±1.82, 0.94±2.13, -0.67±1.98 mm, and 0.91±1.04 degree for group B and 0.12±2.18, - 0.79±2.64, 0.79±2.64 mm, and 0.00±0.49 degree for group C. In this preliminary study, we found the positioning accuracy of the manufactured Shoulder retractor is comparable to other commercial Shoulder retractors. We expect that the reproducibility and accuracy of the patient set-up could be improved by using the home made Shoulder retractor in the head and neck radiation treatment

  1. Evaluation of manufactured device for radiation therapy in head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Jun; Jin, Sun Sik; Kim, Dong Wook; Chung, Weon Kuu; Kim, Kyoung Tae [Dept. of Radiation Oncology, Kyung Hee University Hospital at Gangdong, Seoul (Korea, Republic of)

    2014-06-15

    We compared the set-up accuracy and right-left shoulder position variation of the manufactured device and other commercial shoulder-retractors in the head and neck radiation treatment. Six patients consist of three groups which were used three different Shoulder retractors. We measured position corrections of left and right Shoulder and the couch after the image guidance by using on board imager (OBI) for six head and neck patients who has the extended target to the neck node lower region. The position variation correction of left (right) Shoulder after image guidance were 1.07±3.99 mm (-4.35±2.09 mm), -0.37±5.91 mm (1.26±5.28 mm), -0.63±2.44 mm (0.25±1.61 mm) for group A, B and C. The vertical, lateral, longitudinal position and angular corrections of the couch after image guidance were -2.06±2.68, -1.11±8.15, 0.34±3.78 mm, and 0.51 ±0.77 degree for group A, -1.18±1.82, 0.94±2.13, -0.67±1.98 mm, and 0.91±1.04 degree for group B and 0.12±2.18, - 0.79±2.64, 0.79±2.64 mm, and 0.00±0.49 degree for group C. In this preliminary study, we found the positioning accuracy of the manufactured Shoulder retractor is comparable to other commercial Shoulder retractors. We expect that the reproducibility and accuracy of the patient set-up could be improved by using the home made Shoulder retractor in the head and neck radiation treatment.

  2. Gamma radiation in ceramic capacitors: a study for space missions

    Science.gov (United States)

    dos Santos Ferreira, Eduardo; Sarango Souza, Juliana

    2017-10-01

    We studied the real time effects of the gamma radiation in ceramic capacitors, in order to evaluate the effects of cosmic radiation on these devices. Space missions have electronic circuits with various types of devices, many studies have been done on semiconductor devices exposed to gamma radiation, but almost no studies for passive components, in particular ceramic capacitors. Commercially sold ceramic capacitors were exposed to gamma radiation, and the capacitance was measured before and after exposure. The results clearly show that the capacitance decreases with exposure to gamma radiation. We confirmed this observation in a real time capacitance measurement, obtained using a data logging system developed by us using the open source Arduino platform.

  3. Diamond detectors for synchrotron radiation X-ray applications

    Energy Technology Data Exchange (ETDEWEB)

    De Sio, A. [Laboratori Nazionali di Frascati, INFN, 00044 Frascati, Roma (Italy); Department of Astronomy and Space Science, Universita di Firenze, L.go E. Fermi 2, 50125 Firenze (Italy)], E-mail: desio@arcetri.astro.it; Pace, E. [Department of Astronomy and Space Science, Universita di Firenze, L.go E. Fermi 2, 50125 Firenze (Italy); INFN, Sezione di Firenze, v. G. Sansone 1, Sesto Fiorentino, Firenze (Italy); Cinque, G.; Marcelli, A. [Laboratori Nazionali di Frascati, INFN, 00044 Frascati, Roma (Italy); Achard, J.; Tallaire, A. [LIMHP-CNRS, University of Paris XIII, 99 Avenue JB Clement, 93430 Villetaneuse (France)

    2007-07-15

    Due to its unique physical properties, diamond is a very appealing material for the development of electronic devices and sensors. Its wide band gap (5.5 eV) endows diamond based devices with low thermal noise, low dark current levels and, in the case of radiation detectors, high visible-to-X-ray signal discrimination (visible blindness) as well as high sensitivity to energies greater than the band gap. Furthermore, due to its radiation hardness diamond is very interesting for applications in extreme environments, or as monitor of high fluency radiation beams. In this work the use of diamond based detectors for X-ray sensing is discussed. On purpose, some photo-conductors based on different diamond types have been tested at the DAFNE-L synchrotron radiation laboratory at Frascati. X-ray sensitivity spectra, linearity and stability of the response of these diamond devices have been measured in order to evidence the promising performance of such devices.

  4. Diamond detectors for synchrotron radiation X-ray applications

    International Nuclear Information System (INIS)

    De Sio, A.; Pace, E.; Cinque, G.; Marcelli, A.; Achard, J.; Tallaire, A.

    2007-01-01

    Due to its unique physical properties, diamond is a very appealing material for the development of electronic devices and sensors. Its wide band gap (5.5 eV) endows diamond based devices with low thermal noise, low dark current levels and, in the case of radiation detectors, high visible-to-X-ray signal discrimination (visible blindness) as well as high sensitivity to energies greater than the band gap. Furthermore, due to its radiation hardness diamond is very interesting for applications in extreme environments, or as monitor of high fluency radiation beams. In this work the use of diamond based detectors for X-ray sensing is discussed. On purpose, some photo-conductors based on different diamond types have been tested at the DAFNE-L synchrotron radiation laboratory at Frascati. X-ray sensitivity spectra, linearity and stability of the response of these diamond devices have been measured in order to evidence the promising performance of such devices

  5. External shading devices for energy efficient building

    Science.gov (United States)

    Shahdan, M. S.; Ahmad, S. S.; Hussin, M. A.

    2018-02-01

    External shading devices on a building façade is an important passive design strategy as they reduce solar radiation. Although studies have proven the benefits of external shading devices, many are designed solely for aesthetic purposes without fully considering its high potential to reduce solar radiation and glare. Furthermore, explorations into shading devices by the design team are mostly left too late in the design development phases. Hence, the paper looks into the effectiveness of external shading devices on a building towards more energy efficient building. The study aims to analyse the effects of various configurations of external shading devices towards the energy consumption of a case study building based on computer simulations. This study uses Building Information Modelling (BIM) through Autodesk Revit software as simulation tool. The constant variables for the simulation are the orientation of the building, types of glazing used by the building and the internal loads of the building. Whereas, the manipulated variable is the types of shading device used. The data were sorted according to the categories and translated into a chart. Analysis of the findings indicate that shading devices with different configurations show significant results in the energy consumption and the best configuration is the egg-crate shading devices. The study recommends that the consideration for shading device as a passive design strategy needs to be developed at the early stage of the building design.

  6. Temperature and carrier-density dependence of Auger and radiative recombination in nitride optoelectronic devices

    International Nuclear Information System (INIS)

    Kioupakis, Emmanouil; Yan, Qimin; Steiauf, Daniel; Van de Walle, Chris G

    2013-01-01

    Nitride light-emitting diodes are a promising solution for efficient solid-state lighting, but their performance at high power is affected by the efficiency-droop problem. Previous experimental and theoretical work has identified Auger recombination, a three-particle nonradiative carrier recombination mechanism, as the likely cause of the droop. In this work, we use first-principles calculations to elucidate the dependence of the radiative and Auger recombination rates on temperature, carrier density and quantum-well confinement. Our calculated data for the temperature dependence of the recombination coefficients are in good agreement with experiment and provide further validation on the role of Auger recombination in the efficiency reduction. Polarization fields and phase-space filling negatively impact device efficiency because they increase the operating carrier density at a given current density and increase the fraction of carriers lost to Auger recombination. (paper)

  7. An implantable radiation dosimeter for use in external beam radiation therapy

    International Nuclear Information System (INIS)

    Scarantino, Charles W.; Ruslander, David M.; Rini, Christopher J.; Mann, Gregory G.; Nagle, H. Troy; Black, Robert D.

    2004-01-01

    An implantable radiation dosimeter for use with external beam therapy has been developed and tested both in vitro and in canines. The device uses a MOSFET dosimeter and is polled telemetrically every day during the course of therapy. The device is designed for permanent implantation and also acts as a radiographic fiducial marker. Ten dogs (companion animals) that presented with spontaneous, malignant tumors were enrolled in the study and received an implant in the tumor CTV. Three dogs received an additional implant in collateral normal tissue. Radiation therapy plans were created for the animals and they were treated with roughly 300 cGy daily fractions until completion of the prescribed cumulative dose. The primary endpoints of the study were to record any adverse events due to sensor placement and to monitor any movement away from the point of placement. No adverse events were recorded. Unacceptable device migration was experienced in two subjects and a retention mechanism was developed to prevent movement in the future. Daily dose readings were successfully acquired in all subjects. A rigorous in vitro calibration methodology has been developed to ensure that the implanted devices maintain an accuracy of ±3.5% relative to an ionization chamber standard. The authors believe that an implantable radiation dosimeter is a practical and powerful tool that fosters individualized patient QA on a daily basis

  8. Organic Crystal Growth Facility (OCGF) and Radiation Monitoring Container Device (RMCD) Groups in

    Science.gov (United States)

    1992-01-01

    The primary payload for Space Shuttle Mission STS-42, launched January 22, 1992, was the International Microgravity Laboratory-1 (IML-1), a pressurized manned Spacelab module. The goal of IML-1 was to explore in depth the complex effects of weightlessness of living organisms and materials processing. Around-the-clock research was performed on the human nervous system's adaptation to low gravity and effects of microgravity on other life forms such as shrimp eggs, lentil seedlings, fruit fly eggs, and bacteria. Materials processing experiments were also conducted, including crystal growth from a variety of substances such as enzymes, mercury iodide, and a virus. The Huntsville Operations Support Center (HOSC) Spacelab Payload Operations Control Center (SL POCC) at the Marshall Space Flight Center (MSFC) was the air/ground communication channel used between the astronauts and ground control teams during the Spacelab missions. Featured are activities of the Organic Crystal Growth Facility (OCGF) and Radiation Monitoring Container Device (RMCD) groups in the SL POCC during the IML-1 mission.

  9. Radiative Cooling: Principles, Progress, and Potentials

    Science.gov (United States)

    Hossain, Md. Muntasir

    2016-01-01

    The recent progress on radiative cooling reveals its potential for applications in highly efficient passive cooling. This approach utilizes the maximized emission of infrared thermal radiation through the atmospheric window for releasing heat and minimized absorption of incoming atmospheric radiation. These simultaneous processes can lead to a device temperature substantially below the ambient temperature. Although the application of radiative cooling for nighttime cooling was demonstrated a few decades ago, significant cooling under direct sunlight has been achieved only recently, indicating its potential as a practical passive cooler during the day. In this article, the basic principles of radiative cooling and its performance characteristics for nonradiative contributions, solar radiation, and atmospheric conditions are discussed. The recent advancements over the traditional approaches and their material and structural characteristics are outlined. The key characteristics of the thermal radiators and solar reflectors of the current state‐of‐the‐art radiative coolers are evaluated and their benchmarks are remarked for the peak cooling ability. The scopes for further improvements on radiative cooling efficiency for optimized device characteristics are also theoretically estimated. PMID:27812478

  10. Radiation safety in X-ray facilities

    International Nuclear Information System (INIS)

    2001-09-01

    The guide specifies the radiation safety requirements for structural shielding and other safety arrangements used in X-ray facilities in medical and veterinary X-ray activities and in industry, research and education. The guide is also applicable to premises in which X-ray equipment intended for radiation therapy and operating at a voltage of less than 25 kV is used. The guide applies to new X-ray facilities in which X-ray equipment that has been used elsewhere is transferred. The radiation safety requirements for radiation therapy X-ray devices operating at a voltage exceeding 25 kV, and for the premices in which such devices are used, are set out in Guide ST 2.2

  11. Radiation safety in X-ray facilities

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-09-01

    The guide specifies the radiation safety requirements for structural shielding and other safety arrangements used in X-ray facilities in medical and veterinary X-ray activities and in industry, research and education. The guide is also applicable to premises in which X-ray equipment intended for radiation therapy and operating at a voltage of less than 25 kV is used. The guide applies to new X-ray facilities in which X-ray equipment that has been used elsewhere is transferred. The radiation safety requirements for radiation therapy X-ray devices operating at a voltage exceeding 25 kV, and for the premices in which such devices are used, are set out in Guide ST 2.2.

  12. 21 CFR 892.5750 - Radionuclide radiation therapy system.

    Science.gov (United States)

    2010-04-01

    ... system. (a) Identification. A radionuclide radiation therapy system is a device intended to permit an... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radionuclide radiation therapy system. 892.5750... patient's body. This generic type of device may include signal analysis and display equipment, patient and...

  13. Radiation Protection, Safety and Security Issues in Ghana

    International Nuclear Information System (INIS)

    Boadu, M. B.; Emi-Reynolds, G.; Amoako, J. K.; Hasford, F.; Akrobortu, E.

    2015-01-01

    The Radiation Protection Board was established in 1993 by PNDC Law 308 as the National Competent Authority for the regulation of radiation sources and radioactive materials in Ghana. The mandate and responsibilities of RPB are prescribed in the legislative instrument, LI 1559 issued in 1993. The operational functions of the Board are carried out by the Radiation Protection Institute, which was established to provide technical support for the enforcement of the legislative instrument. The regulatory activities include among others: – Issuance permits for the import/export of any radiation producing device and radioactive materials into/out of the country. It therefore certifies the radioactivity levels in food and the environmental samples. – Authorization and Inspection of practices using radiation sources and radioactive materials in Ghana. – Undertakes safety assessment services and enforcement actions on practices using radiation sources and radioactive materials in line with regulations. – Provides guidance and technical support in fulfilling regulatory requirement to users of radiation producing devices and radioactive materials nationwide by monitoring of monthly radiation absorbed doses for personnel working at radiation facilities. – Provides support to the management of practices in respect of nuclear and radioactive waste programme. – Calibrates radiation emitting equipment and nuclear instrumentation to ensure the safety of patients, workers and the general public. – Establish guidelines for the mounting (non-ionizing) communication masts. – Environmental monitoring (non-ionizing) programmes for communication masts. With the establishment of the national competent authority, facilities using radioactive sources and radiation emitting devices have been brought under regulatory control. Effective regulatory control of radiation emitting devices are achieved through established legal framework, independent Regulatory Authority supported by

  14. A simple quality assurance test tool for the visual verification of light and radiation field congruent using electronic portal images device and computed radiography

    Directory of Open Access Journals (Sweden)

    Njeh Christopher F

    2012-03-01

    Full Text Available Abstract Background The radiation field on most megavoltage radiation therapy units are shown by a light field projected through the collimator by a light source mounted inside the collimator. The light field is traditionally used for patient alignment. Hence it is imperative that the light field is congruent with the radiation field. Method A simple quality assurance tool has been designed for rapid and simple test of the light field and radiation field using electronic portal images device (EPID or computed radiography (CR. We tested this QA tool using Varian PortalVision and Elekta iViewGT EPID systems and Kodak CR system. Results Both the single and double exposure techniques were evaluated, with double exposure technique providing a better visualization of the light-radiation field markers. The light and radiation congruency could be detected within 1 mm. This will satisfy the American Association of Physicists in Medicine task group report number 142 recommendation of 2 mm tolerance. Conclusion The QA tool can be used with either an EPID or CR to provide a simple and rapid method to verify light and radiation field congruence.

  15. Thermonuclear device

    International Nuclear Information System (INIS)

    Honda, Takuro; Maki, Koichi.

    1997-01-01

    The present invention provides a thermonuclear device, in which integrity of a measuring device is kept, the reactor wall temperature and wear of armour materials are monitored accurately even under intense radiation rays, so that the flow rate of coolants and plasma power can be controlled by using the signals. Infrared rays generated from the surface of the armour materials disposed on a first wall are detected to measure the reactor wall temperature. Coolant flow rate and plasma power are controlled based on the obtained reactor wall temperature. In addition, infrared rays generated from the back of the armour materials are detected to obtain the surface temperature in order to avoid intense radiation rays from plasmas. The coolant flow rate and the plasma power are controlled based on the obtained temperature on the surface of the reactor thereby controlling the temperature of the first wall and the armour material to 300degC or lower in a case of the first wall made of stainless steel and 1000degC or lower in a case of the armour material made of graphite. (I.S.)

  16. Status of radiation detector and neutron monitor technology

    CERN Document Server

    Kim, Y K; Ha, J H; Han, S H; Hong, S B; Hwang, I K; Lee, W G; Moon, B S; Park, S H; Song, M H

    2002-01-01

    In this report, we describe the current states of the radiation detection technology, detectors for industrial application, and neutron monitors. We also survey the new technologies being applied to this field. The method to detect radiation is the measurement of the observable secondary effect from the interaction between incident radiation and detector material, such as ionization, excitation, fluorescence, and chemical reaction. The radiation detectors can be categorized into gas detectors, scintillation detectors, and semiconductor detectors according to major effects and main applications. This report contains the current status and operational principles of these detectors. The application fields of radiation detectors are industrial measurement system, in-core neutron monitor, medical radiation diagnostic device, nondestructive inspection device, environmental radiation monitoring, cosmic-ray measurement, security system, fundamental science experiment, and radiation measurement standardization. The st...

  17. Radiation Safety Professional Certification Process in a Multi-Disciplinary Association

    International Nuclear Information System (INIS)

    Wilson, G.; Jones, P.; Ilson, R.

    2004-01-01

    There is no one set of criteria that defines the radiation safety professional in Canada. The many varied positions, from university and medical to industry and mining, define different qualifications to manage radiation safety programs. The national regulatory body has to assess many different qualifications when determining if an individual is acceptable to be approved for the role of radiation safety officer under any given licence. Some professional organizations specify education requirements and work experience as a prerequisite to certification. The education component specifies a degree of some type but does not identify specific courses or competencies within that degree. This could result in individuals with varying levels of radiation safety experience and training. The Canadian Radiation Protection Association (CRPA), responding to a need identified by the membership of the association, has initiated a process where the varying levels of knowledge of radiation safety can be addressed for radiation safety professionals. By identifying a core level set of radiation safety competencies, the basic level of radiation safety officer for smaller organizations can be met. By adding specialty areas, education can be pursued to define the more complex needs of larger organizations. This competency based process meets the needs of licensees who do not require highly trained health physicists in order to meet the licensing requirements and at the same time provides a stepping stone for those who wish to pursue a more specialized health physics option. (Author) 8 refs

  18. Conical electromagnetic radiation flux concentrator

    Science.gov (United States)

    Miller, E. R.

    1972-01-01

    Concentrator provides method of concentrating a beam of electromagnetic radiation into a smaller beam, presenting a higher flux density. Smaller beam may be made larger by sending radiation through the device in the reverse direction.

  19. Television imaging transducers for use in radiation fields

    International Nuclear Information System (INIS)

    Konyaev, V.M.; Krasovskij, S.S.; Surikov, I.N.

    1989-01-01

    For optical television equipment widely used in nuclear energetics it appears to be importance to account for various radiation effects on the device material and units aiming at diminishing negative effects of radiation upon the devices operation. Basing on the experimental results (along with the analysis of literature data) the authors propose a mechanism of radiation effect upon television imaging sensors (TIS). Operation principles and construction of up-to date TIS are briefly described, as well as the characteristics of radiation conditions. Various radiation effects upon the TIS material and construction have been considered. Optimal radiation conditions and levels have been suggested for the equipment operation. The efficiencies of various TIS are compared. 230 refs.; 86 figs.; 4 tabs

  20. Studies on the radiation resistances of bioburden for medical devices

    International Nuclear Information System (INIS)

    Sekiguchi, Masayuki; Tabei, Masae

    1997-01-01

    Radiation resistances of reference bacteria strains and the bioburden obtained from hypodermic needles were estimated with gamma- and electron- irradiators calibrated with NPL (National Physics Laboratory) alanine dosimeter. Radiation resistances of the TSB-bacteria suspension samples dried on glass test tubes showed about two times higher than those of the water-bacteria suspension dried on glass fiber paper or paper filter. Radiation resistances of the dried TSB-bacteria suspension samples irradiated by both gamma rays and electron beams were fluctuated. The overall increase ratio of radiation resistance was estimated by dividing D-values of TSB-bacteria suspension samples by that of water-bacteria suspension samples for individual bacteria. Then, the survival curve of hypodermic needle bioburden revised by the increase ratio was obtained, and which compared with that of standard distribution of radiation resistances of ISO(SDR). (author)