WorldWideScience

Sample records for radiation detection instrumentation

  1. Cellular telephone-based radiation detection instrument

    Science.gov (United States)

    Craig, William W [Pittsburg, CA; Labov, Simon E [Berkeley, CA

    2011-06-14

    A network of radiation detection instruments, each having a small solid state radiation sensor module integrated into a cellular phone for providing radiation detection data and analysis directly to a user. The sensor module includes a solid-state crystal bonded to an ASIC readout providing a low cost, low power, light weight compact instrument to detect and measure radiation energies in the local ambient radiation field. In particular, the photon energy, time of event, and location of the detection instrument at the time of detection is recorded for real time transmission to a central data collection/analysis system. The collected data from the entire network of radiation detection instruments are combined by intelligent correlation/analysis algorithms which map the background radiation and detect, identify and track radiation anomalies in the region.

  2. IAEA eLearning Program: The Use of Radiation Detection Instruments

    International Nuclear Information System (INIS)

    2010-01-01

    This CD-ROM contains a computer based training on Radiation Detection Techniques for Nuclear Security Applications. The IAEA Nuclear Security eLearning tool offers computer based training to Frontline Officers to improve their understanding about key elements of the use of radiation detection instruments. The eLearning program prepares Frontline Officers for the IAEA Detection and Response Frontline Officer course

  3. Nuclear instrumentation for radiation measurement

    International Nuclear Information System (INIS)

    Madan, V.K.

    2012-01-01

    Nuclear radiation cannot be detected by human senses. Nuclear detectors and associated electronics facilitate detection and measurement of different types of radiation like alpha particles, beta particles, gamma radiation, and detection of neutrons. Nuclear instrumentation has evolved greatly since the discovery of radioactivity. There has been tremendous advancement in detector technology, electronics, computer technology, and development of efficient algorithms and methods for spectral processing to extract precisely qualitative and quantitative information of the radiation. Various types of detectors and nuclear instruments are presently available and are used for different applications. This paper describes nuclear radiation, its detection and measurement and associated electronics, spectral information extraction, and advances in these fields. The paper also describes challenges in this field

  4. Specialized instrument for radiation assistance teams

    International Nuclear Information System (INIS)

    Applegate, J.A.

    1985-08-01

    A specialized multiradiation instrument for radiation assistance teams (RAT's) has been designed; a working prototype has been constructed and field tested. The instrument detects alpha, beta, and gamma radiation simultaneously with simple red, yellow, and green meter indications and audio outputs. It is basically intended for DOE radiation assistance teams but would have application to any government, military, or industrial radiation accident team

  5. Cellular telephone-based wide-area radiation detection network

    Science.gov (United States)

    Craig, William W [Pittsburg, CA; Labov, Simon E [Berkeley, CA

    2009-06-09

    A network of radiation detection instruments, each having a small solid state radiation sensor module integrated into a cellular phone for providing radiation detection data and analysis directly to a user. The sensor module includes a solid-state crystal bonded to an ASIC readout providing a low cost, low power, light weight compact instrument to detect and measure radiation energies in the local ambient radiation field. In particular, the photon energy, time of event, and location of the detection instrument at the time of detection is recorded for real time transmission to a central data collection/analysis system. The collected data from the entire network of radiation detection instruments are combined by intelligent correlation/analysis algorithms which map the background radiation and detect, identify and track radiation anomalies in the region.

  6. Radiation measuring instrument

    International Nuclear Information System (INIS)

    Genrich, V.

    1985-01-01

    A highly sensitive and compactly structured radiation measuring instrument for detecting ionizing radiation, in particular for measuring dose rates and contamination. The laminar structure of the associated counter tube, using only a few, simple plastic parts and a highly elastic counter wire, makes it possible to use the simplest manufacturing techniques. The service life of the counter tube construction, which is completely and permanently sealed and filled with gas, is expected to be more than 12 years. The described counter tube can be adapted in optimal fashion to the available space in a pocket instrument if it is used in combination with a specialized high-voltage generator which is low in interference voltage and with a pulse evaluation circuit having a means of compensating for interference voltage

  7. Portable neutron and gamma-radiation instruments

    International Nuclear Information System (INIS)

    Murray, W.S.; Butterfield, K.B.

    1990-01-01

    This paper reports on the design and building of a smart neutron and gamma-radiation detection systems with embedded microprocessors programmed in the FORTH language. These portable instruments can be battery-powered and can provide many analysis functions not available in most radiation detectors. Local operation of the instruments is menu-driven through a graphics liquid crystal display and hex keypad; remote operation is through a serial communications link. While some instruments simply count particles, others determine the energy of the radiation as well as the intensity. The functions the authors have provided include absolute source-strength determination. Feynmann variance analysis, sequential-probability ratio test, and time-history recording

  8. L-34: EPR-First Responders: Basic Radiation Instrumentation

    International Nuclear Information System (INIS)

    2011-01-01

    This lecture is about radiation basic instrumentation, previous measurements, personnel dosimetry, Geiger Mueller, ionizing chambers, gamma spectrometry, contamination monitoring and radiation detection.

  9. Measurement and detection of radiation

    CERN Document Server

    Tsoulfanidis, Nicholas

    2011-01-01

    This is an update of the standard textbook for the field of radiation measurement. It includes illustrative examples and new problems. The research and applications of nuclear instrumentation have grown substantially since publication of the previous editions. With the miniaturization of equipment, increased speed of electronic components, and more sophisticated software, radiation detection systems are now more productively used in many disciplines, including nuclear nonproliferation, homeland security, and nuclear medicine. Continuing in the tradition of its bestselling predecessors, "Measurement and Detection of Radiation, Third Edition" illustrates the fundamentals of nuclear interactions and radiation detection with a multitude of examples and problems. It offers a clearly written, accessible introduction to nuclear instrumentation concepts. The following are new to the third edition: a new chapter on the latest applications of radiation detection, covering nuclear medicine, dosimetry, health physics, no...

  10. New-generation low-power radiation survey instruments

    International Nuclear Information System (INIS)

    Waechter, D.A.; Bjarke, G.O.; Wolf, M.A.; Trujillo, F.; Umbarger, C.J.

    1983-01-01

    A number of new, ultra-low-powered radiation instruments have recently been developed at Los Alamos. Among these are two instruments which use a novel power source to eliminate costly batteries. The newly developed gamma detecting radiac, nicknamed the Firefly, and the alpha particle detecting instrument, called the Simple Cordless Alpha Monitor, both use recent advances in miniaturization and power-saving electronics to yield devices which are small, rugged, and very power-frugal. The two instruments consume so little power that the need for batteries to run them is eliminated. They are, instead, powered by a charged capacitor which will operate the instruments for an hour or more. Both line power and mechanical sources are used to charge the storage capacitors which power the instruments

  11. Design of autotrack detecting instrument for solar UV radiation

    Science.gov (United States)

    Xia, Jiangtao; Mao, Xiaoli; Zhao, Jing

    2009-11-01

    In order to autotrack the object and detect the solar UV index, a reliable real-time high-precise instrument is proposed in this paper. This instrument involves two subsystems: the autotrack and detecting modules. The autotrack module consists of four-quadrant photo detector, multi-channel signal processing circuit and precise stepping system. The detecting module designed for dada measurement and acquisition is made up of the ultraviolet sensor UV460 and high precision A/D converter MAX1162. The key component of the entire instrument is ultralow-power microprocessor MSP430 which is used for entire system controlling and data processing. The lower system of autotracking and measurement is communicated with upper PC computer by RS232 module. In the experiment, the tracking precision of two-dimensional motion revolving stage is calibrated to be less than 0.05°. Experimental results indicate that the system designed could realize the precise autotracking and detecting function well, and the measure precision of system has reached the desirable target.

  12. Radiation protection instrument 1993

    International Nuclear Information System (INIS)

    1993-04-01

    The Radiation Protection Instrument, 1993 (Legislative Instrument 1559) prescribes the powers and functions of the Radiation Protection Board established under the Ghana Atomic Energy Commission by the Atomic Energy Commission (Amendment) Law, 1993 (P.N.D.C. Law 308). Also included in the Legislative Instrument are schedules on control and use of ionising radiation and radiation sources as well as procedures for notification, licensing and inspection of ionising radiation facilities. (EAA)

  13. Detection and measurement of ionizing radiation

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    All detection or measurement of radiation rests in the possibility of recognizing the interactions of radiation with matter. When radiation passes through any kind of material medium, all or a portion of its energy is transferred to this medium. This transferred energy produces an effect in the medium. In principle, the detection of radiation is based on the appearance and the observation of this effect. In theory, all of the effects produced by radiation may be used in detecting it: in practice, the effects most commonly employed are: (1) ionization of gases (gas detectors), or of some chemical substance which is transformed by radiation (photographic or chemical dosimeters); (2) excitations in scintillators or semiconductors (scintillation counters, semiconductor counters); (3) creation of structural defects through the passage of radiation (transparent thermoluminescent and radioluminescent detectors); and (4) raising of the temperature (calorimeters). This study evaluates in detail, instruments based on the ionization of gases and the production of luminescence. In addition, the authors summarize instruments which depend on other forms of interaction, used in radiation medicine and hygiene (radiology, nuclear medicine)

  14. Instrumentation for environmental monitoring. Volume 1. Radiation. Second Edition

    International Nuclear Information System (INIS)

    Budnitz, R.J.; Nero, A.V.; Murphy, D.J.; Graven, R.

    1983-01-01

    This volume describes ionizing radiation and the instruments used for measurement. Units, sources, and effects of radiation are introduced, basic detection methods discussed, and measurement of alpha, beta, gamma and x-radiation described. Sources of anthropogenic radiation are discussed in detail: nuclear power plants, spent-fuel processing, and uranium mining and milling

  15. New generation low power radiation survey instruments

    International Nuclear Information System (INIS)

    Waechter, D.A.; Bjarke, G.O.; Trujillo, F.; Umbarger, C.J.; Wolf, M.A.

    1984-01-01

    A number of new, ultra-low-powered radiation instruments have recently been developed at Los Alamos. Among these are two instruments which use a novel power source to eliminate costly batteries. The newly developed gamma detecting radiac, nicknamed the Firefly, and the alpha particle detecting instrument, called the Simple Cordless Alpha Monitor, both use recent advances in miniaturization and powersaving electronics to yield devices which are small, rugged, and very power-frugal. The two instruments consume so little power that the need for batteries to run them is eliminated. They are, instead, powered by a charged capacitor which will operate the instruments for an hour or more. Use of a capacitor as a power source eliminates many problems commonly associated with battery-operated instruments, such as having to open the case to change batteries, battery storage life, availability of batteries in the field, and some savings in weight. Both line power and mechanical sources are used to charge the storage capacitors which power the instruments

  16. Recent advances in radiation protection instrumentation

    International Nuclear Information System (INIS)

    Babu, D.A.R.

    2012-01-01

    Radiation protection instrumentation plays very important role in radiation protection and surveillance programme. Radiation detector, which appears at the frontal end of the instrument, is an essential component of these instruments. The instrumental requirement of protection level radiation monitoring is different from conventional radiation measuring instruments. Present paper discusses the new type of nuclear radiation detectors, new protection level instruments and associated electronic modules for various applications. Occupational exposure to ionizing radiation can occur in a range of industries, such as nuclear power plants; mining and milling; medical institutions; educational and research establishments; and nuclear fuel cycle facilities. Adequate radiation protection to workers is essential for the safe and acceptable use of radioactive materials for different applications. The radiation exposures to the individual radiation workers and records of their cumulative radiation doses need to be routinely monitored and recorded

  17. Instrumentation measurement and testing complex for detection and identification of radioactive materials using the emitted radiation

    International Nuclear Information System (INIS)

    Samossadny, V.T.; Dmitrenko, V.V.; Kadlin, V.V.; Kolesnikov, S.V.; Ulin, S.E.; Grachev, V.M.; Vlasik, K.F.; Dedenko, G.L.; Novikov, D.V.; Uteshev, Z.M.

    2006-01-01

    Simultaneous measurement of neutron and gamma radiation is a very usefull method for effective nuclear materials identification and control. The gamma-ray-neutron complex described in the paper is based on two multi-layer 3 He neutrons detectors and two High Pressure Xenon gamma-ray spectrometers assembled in one unit. All these detectors were callibrated on neutron and gamma-ray sources. The main characteristics of the instrumentation , its testing results and gamma-ray and neutron radiation parameters, which have been measured are represented in the paper. The gamma-neutron sources and fissile materials reliable detection and identification capability was demonstrated

  18. New type of radiation instrumentation system

    International Nuclear Information System (INIS)

    Matsuo, Keichi; Takaoka, Akira; Uranaka, Yasuo

    2000-01-01

    The Mitsubishi Electric Co., Ltd. developed a radiation instrumentation system introduced some recent techniques such as computation technique, network technique and so on into conventional radiation detection aiming at general market except power generation company. In a conventional system, a detector and an operation processing board was placed at a field and center, respectively, and a feeble pulse signal from the detector was transferred to the operation processing board. Then, on establishment of cables, detectors and operation processing board, it is essential to carry out engineering planning and field engineering conceiving on noise countermeasure. Noise resistance of the new type of radiation instrumentation system, not by adding operation processing function and network interface function into a detector unit in a field to transfer feeble signal, but by transferring testing result as a digital signal. And, noise removing function capable of selectively passing only signal pulse waveform from the detector to judge its signal waveform was also added to a detector unit in the field, to carry out a thoroughly removing noise. In addition, by connecting between each apparatus placed at the field with a network a system capable of reducing some cable engineering could be executed. Here were introduced on abstract of this new type of radiation instrumentation system and on noise removing function of its characteristics. (G.K.)

  19. Calibration of radiation monitoring instruments

    International Nuclear Information System (INIS)

    1973-01-01

    Radiation protection is dependent on good radiation monitoring, and properly calibrated instruments are essential for this work. Simple procedures for periodically checking and recalibrating different kinds of radiation monitoring instruments are shown in this training film

  20. Calibration of radiation monitoring instruments

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1974-12-31

    Radiation protection is dependent on good radiation monitoring, and properly calibrated instruments are essential for this work. Simple procedures for periodically checking and recalibrating different kinds of radiation monitoring instruments are shown in this training film

  1. Radiation, ionization, and detection in nuclear medicine

    International Nuclear Information System (INIS)

    Gupta, Tapan K.

    2013-01-01

    Up-to-date information on a wide range of topics relating to radiation, ionization, and detection in nuclear medicine. In-depth coverage of basic radiophysics relating to diagnosis and therapy. Extensive discussion of instrumentation and radiation detectors. Detailed information on mathematical modelling of radiation detectors. Although our understanding of cancer has improved, the disease continues to be a leading cause of death across the world. The good news is that the recent technological developments in radiotherapy, radionuclide diagnostics and therapy, digital imaging systems, and detection technology have raised hope that cancer will in the future be combatted more efficiently and effectively. For this goal to be achieved, however, safe use of radionuclides and detailed knowledge of radiation sources are essential. Radiation, Ionization, and Detection in Nuclear Medicine addresses these subjects and related issues very clearly and elaborately and will serve as the definitive source of detailed information in the field. Individual chapters cover fundamental aspects of nuclear radiation, including dose and energy, sources, and shielding; the detection and measurement of radiation exposure, with detailed information on mathematical modelling; medical imaging; the different types of radiation detector and their working principles; basic principles of and experimental techniques for deposition of scintillating materials; device fabrication; the optical and electrical behaviors of radiation detectors; and the instrumentation used in nuclear medicine and its application. The book will be an invaluable source of information for academia, industry, practitioners, and researchers.

  2. Radiation, ionization, and detection in nuclear medicine

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Tapan K. [Radiation Monitoring Devices Research, Nuclear Medicine, Watertown, MA (United States)

    2013-08-01

    Up-to-date information on a wide range of topics relating to radiation, ionization, and detection in nuclear medicine. In-depth coverage of basic radiophysics relating to diagnosis and therapy. Extensive discussion of instrumentation and radiation detectors. Detailed information on mathematical modelling of radiation detectors. Although our understanding of cancer has improved, the disease continues to be a leading cause of death across the world. The good news is that the recent technological developments in radiotherapy, radionuclide diagnostics and therapy, digital imaging systems, and detection technology have raised hope that cancer will in the future be combatted more efficiently and effectively. For this goal to be achieved, however, safe use of radionuclides and detailed knowledge of radiation sources are essential. Radiation, Ionization, and Detection in Nuclear Medicine addresses these subjects and related issues very clearly and elaborately and will serve as the definitive source of detailed information in the field. Individual chapters cover fundamental aspects of nuclear radiation, including dose and energy, sources, and shielding; the detection and measurement of radiation exposure, with detailed information on mathematical modelling; medical imaging; the different types of radiation detector and their working principles; basic principles of and experimental techniques for deposition of scintillating materials; device fabrication; the optical and electrical behaviors of radiation detectors; and the instrumentation used in nuclear medicine and its application. The book will be an invaluable source of information for academia, industry, practitioners, and researchers.

  3. New developments in radiation protection instrumentation via active electronic methods

    International Nuclear Information System (INIS)

    Umbarger, C.J.

    1981-01-01

    New developments in electronics and radiation detectors are improving on real-time data acquisition of radiation exposure and contamination conditions. Recent developments in low power circuit designs, hybrid and integrated circuits, and microcomputers have all contributed to smaller and lighter radiation detection instruments that are, at the same time, more sensitive and provide more information (e.g., radioisotope identification) than previous devices. New developments in radiation detectors, such as cadmium telluride, gas scintillation proportional counters, and imaging counters (both charged particle and photon) promise higher sensitivities and expanded uses over present instruments. These developments are being applied in such areas as health physics, waste management, environmental monitoring, in vivo measurements, and nuclear safeguards

  4. Parallel Study of HEND, RAD, and DAN Instrument Response to Martian Radiation and Surface Conditions

    Science.gov (United States)

    Martiniez Sierra, Luz Maria; Jun, Insoo; Litvak, Maxim; Sanin, Anton; Mitrofanov, Igor; Zeitlin, Cary

    2015-01-01

    Nuclear detection methods are being used to understand the radiation environment at Mars. JPL (Jet Propulsion Laboratory) assets on Mars include: Orbiter -2001 Mars Odyssey [High Energy Neutron Detector (HEND)]; Mars Science Laboratory Rover -Curiosity [(Radiation Assessment Detector (RAD); Dynamic Albedo Neutron (DAN))]. Spacecraft have instruments able to detect ionizing and non-ionizing radiation. Instrument response on orbit and on the surface of Mars to space weather and local conditions [is discussed] - Data available at NASA-PDS (Planetary Data System).

  5. The latest radiation instrument

    International Nuclear Information System (INIS)

    Kang, Se Sik; Gwon, Dal Gwan; Kim, Gyeong Geum

    2008-08-01

    This book deals with the latest radiation instrument, which is comprised of eight chapters. It explains X rays instrument for medial treatment, X-ray tube instrument and permissible burden with its history, structure and characteristic high voltage apparatus with high voltage rectifier circuit, X-ray control apparatus for medical treatment, X-ray image equipment X-ray television apparatus and CCD 205, X-ray apparatus of install and types, Digital X-ray apparatus with CR 261 and DR 269, performance management on X-ray for medical treatment with its history, necessity and management in the radiation field.

  6. Development of international standards for instrumentation used for detection of illicit trafficking of radioactive material

    International Nuclear Information System (INIS)

    Voytchev, M.; Chiaro, P.; Radev, R.

    2006-01-01

    Subcommittee 45 B 'Radiation Protection Instrumentation' of the International Electrotechnical Commission (I.E.C.) is charged with the development of international standards for instrumentation used for monitoring of illicit trafficking of radioactive material through international boarders and territories, as well as inside countries. Currently three I.E.C. standards are in advanced stages of development. They are expected to be approved and published in 2006-2007. The international participation and the main characteristics of the following three standards are discussed and presented: I.E.C. 62327 'Hand-held Instruments for the Detection and Identification of Radionuclides and Additionally for the Indication of Ambient Dose Equivalent Rate from Photon Radiation', I.E.C. 62401 'Alarming Personal Radiation Devices for Detection of Illicit Trafficking of Radioactive Material' and I.E.C. 62244 'Installed Radiation Monitors for the Detection of Radioactive and Special Nuclear Materials at National Borders'

  7. Development of international standards for instrumentation used for detection of illicit trafficking of radioactive material

    Energy Technology Data Exchange (ETDEWEB)

    Voytchev, M. [Institut de Radioprotection et de Surete Nucleaire (IRSN/DSU/SERAC/CTHIR), 91 - Gif sur Yvette (France); Chiaro, P. [Oak Ridge National Lab., TN (United States); Radev, R. [LLNL, Livermore, CA (United States)

    2006-07-01

    Subcommittee 45 B 'Radiation Protection Instrumentation' of the International Electrotechnical Commission (I.E.C.) is charged with the development of international standards for instrumentation used for monitoring of illicit trafficking of radioactive material through international boarders and territories, as well as inside countries. Currently three I.E.C. standards are in advanced stages of development. They are expected to be approved and published in 2006-2007. The international participation and the main characteristics of the following three standards are discussed and presented: I.E.C. 62327 'Hand-held Instruments for the Detection and Identification of Radionuclides and Additionally for the Indication of Ambient Dose Equivalent Rate from Photon Radiation', I.E.C. 62401 'Alarming Personal Radiation Devices for Detection of Illicit Trafficking of Radioactive Material' and I.E.C. 62244 'Installed Radiation Monitors for the Detection of Radioactive and Special Nuclear Materials at National Borders'.

  8. Traceability of radiation protection instruments

    Science.gov (United States)

    Hino, Y.; Kurosawa, T.

    2007-08-01

    Radiation protection instruments are used in daily measurement of dose and activities in workplaces and environments for safety management. The requirements for calibration certificates with traceability are increasing for these instruments to ensure the consistency and reliabilities of the measurement results. The present traceability scheme of radiation protection instruments for dose and activity measurements is described with related IEC/ISO requirements. Some examples of desirable future calibration systems with recent new technologies are also discussed to establish the traceability with reasonable costs and reliabilities.

  9. Tesla VUPJT instruments for radiation monitoring of working environment and selected aplications

    International Nuclear Information System (INIS)

    Slezak, V.; Kula, J.; Novakova, O.; Jursova, L.; Severa, L.

    1986-01-01

    A survey is presented of the current state of development and production of instruments for ionizing radiation monitoring and detection, also listing possible applications in the national economy. (author)

  10. Multichannel Digital Emulator of Radiation Detection Systems

    International Nuclear Information System (INIS)

    Abba, A.; Caponio, F.; Geraci, A.

    2013-06-01

    A digital system for emulating in real time signals from generic setups for radiation detection is presented. The instrument is not a pulse generator of recorded shapes but a synthesizer of random pulses compliant to programmable statistics for energy and occurrence time. Completely programmable procedures for emulation of noise, disturbances and reference level variation can be implemented. The instrument has been realized and fully tested. (authors)

  11. Radiation monitoring instrumentation for nuclear power plants

    International Nuclear Information System (INIS)

    Bharath Kumar, M.

    2013-01-01

    Measurement of nucleonic signals is required to control and operate the reactor in a safe and reliable manner. To achieve this, parameters like Neutron flux, other radiation fields, contamination levels, source strength, release thru stack etc. are required to be monitored and controlled. The above are required to be monitored throughout the life of the reactor whether it is operational or in shutdown condition. In addition such monitoring is also required during decommissioning phase of the reactor as needed. To measure these parameters a large number of instruments are used in Nuclear Power Plants (NPP) which includes sensors and electronics for detecting alpha, beta, gamma and neutron radiation with qualification to withstand harsh environment

  12. Current state of commercial radiation detection equipment for homeland security applications

    International Nuclear Information System (INIS)

    Klann, R.T.; Shergur, J.; Mattesich, G.

    2009-01-01

    With the creation of the U.S. Department of Homeland Security (DHS) came the increased concern that terrorist groups would attempt to manufacture and use an improvised nuclear device or radiological dispersal device. As such, a primary mission of DHS is to protect the public against the use of these devices and to assist state and local responders in finding, locating, and identifying these types of devices and materials used to manufacture these devices. This assistance from DHS to state and local responders comes in the form of grant money to procure radiation detection equipment. In addition to this grant program, DHS has supported the development of American National Standards Institute standards for radiation detection equipment and has conducted testing of commercially available instruments. This paper identifies the types and kinds of commercially available equipment that can be used to detect and identify radiological material - for use in traditional search applications as well as primary and secondary screening of personnel, vehicles, and cargo containers. In doing so, key considerations for the conduct of operations are described as well as critical features of the instruments for specific applications. The current state of commercial instruments is described for different categories of detection equipment including personal radiation detectors, radioisotope identifiers, man-portable detection equipment, and radiation portal monitors. In addition, emerging technologies are also discussed, such as spectroscopic detectors and advanced spectroscopic portal monitors

  13. Regulatory requirements and quality assurance of radiation monitoring instruments

    International Nuclear Information System (INIS)

    Narasimharao, K.L.; Sharma, Ranjit

    2005-01-01

    The successful utilisation of radiation sources in the fields of medicine and industry requires the accurate measurement of activity, exposure rate and dose. Many varieties of instruments are in use for measurement of these parameters and new ones are being developed. The criteria for the design of the radiation monitoring instrument include the type and intensity of the radiation, purpose of measurement and ruggedness of the instrument. Quality and reliability of radiation monitoring instruments ensure that individuals are adequately protected. Accuracy, response time and ruggedness are required to be as per the approved/ prescribed guidelines. Regulatory authorities outline the design and performance criteria for radiation monitoring instruments and prescribe the recommendations of international agencies such as IAEA, ICRU and ISO for radiological measurement assurance programme. National Standards Laboratories all over the world prescribe procedures for calibration of various radiation monitoring instruments. The instruments should be calibrated as per these guidelines and should be traceable to national standards. The calibration traceable to national/ international standards and documentation as well as limits stipulated by the competent authority ensures the expected performance of the instrument. (author)

  14. An Experiment in Radiation Measurement Using the Depron Instrument

    Science.gov (United States)

    Benghin, Victor V.; Nechaev, Oleg Y.; Zolotarev, Ivan A.; Amelyushkin, Alexander M.; Petrov, Vasiliy L.; Panasyuk, Milhail I.; Yashin, Ivan V.

    2018-02-01

    Most of the radiation measurements have been made onboard spacecraft flying along orbits with an inclination of up to 51.6 degrees. Due to the prospect of manned missions at orbits with larger inclinations, it is advisable to conduct preliminary detailed dosimetry measurements at a high-inclination orbit; due to its polar orbit, the Lomonosov satellite provides good opportunities for such study. We chose a method of cosmic radiation dosimetry based on semiconductor detectors. This method is widely used onboard spacecraft, including full-time radiation monitoring onboard the International Space Station (ISS). It should be noted that not only did the charged particles contribute significantly in the dose equivalent, but also did the neutrons. Semiconductor detectors have low sensitivity to neutron radiation and are not sufficient for detecting the expected flux of neutrons. We add a thermal neutron counter to the proposed device in order to provide an opportunity for estimation of neutron flux variations along the satellite trajectory. Thus, the design of the instrument DEPRON (Dosimeter of Electrons, PROtons and Neutrons) was determined. DEPRON is intended for registration of the absorbed doses and linear energy transfer spectra for high-energy electrons, protons and nuclei of space radiation, as well as registration of thermal neutrons. The present paper provides a brief description of the DEPRON instrument. Its calibration results and the first mission results of background radiation measurements are also presented.

  15. Radiation detection and measurement

    International Nuclear Information System (INIS)

    Knoll, G.F.

    1979-01-01

    The book is a complete, clear and up-to-date text that provides a basic review of instruments and methods of ionizing radiation. The text covers detailed discussion of all detector types introductory discussions of radiation sources, interactions, and counting statistics functional analysis of the electronics and pulse processing aspects of radiation detectors in instrumentation systems and consideration of shielding and background potentially vital in low-level counting. A total of 350 figures and approximately 900 references to current scientific literature is included. The book is largely intended as a textbook for a junior/senior or first-year graduate course in nuclear instrumentation and radiation measurements

  16. Current situation and prospect of market on the latest radiation measuring instrument

    International Nuclear Information System (INIS)

    Ha, Chang Ho; Kim, Wang Geum; Cho, Gyu Seong

    2009-12-01

    This book deals with current situation and prospect of market on the latest radiation measuring instrument. The contents of this book are basic of technology on radiation measuring instrument with basic principle of various measuring instrument, current situation of technology and prospect of radiation measuring instrument, effect of spreading and application field of radiation measuring instrument, facility for making and research and development of radiation measuring instrument, prospect of market about radiation measuring instrument, strategy for market entry with the latest radiation measuring instrument and general prospect for the future.

  17. Calibration of solar radiation measuring instruments. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Bahm, R J; Nakos, J C

    1979-11-01

    A review of solar radiation measurement of instruments and some types of errors is given; and procedures for calibrating solar radiation measuring instruments are detailed. An appendix contains a description of various agencies who perform calibration of solar instruments and a description of the methods they used at the time this report was prepared. (WHK)

  18. Evaluation of radiation protection instrumentation: the C.T.H.I.R.. Poster and booklet for activity presentation

    International Nuclear Information System (INIS)

    Bicheron, G.; Ginisty, C.

    1998-01-01

    Among all the components required for radiation protection optimization, the evaluation of instrumentation is essential. The instrumentation in radiation protection allows to make the surveillance of personnel, installations and environment against the risk bound to radioactive contamination and ionizing radiations. The different devices can give the following functions: ambient dosimetry, (individual and environmental dosimetry), measurement of surface contaminations, air contamination by aerosols or gas, water contamination by liquid wastes,detection of criticality accidents, measurement of samples radioactivity. (N.C.)

  19. Radiation Detection for Homeland Security Applications

    Science.gov (United States)

    Ely, James

    2008-05-01

    In the past twenty years or so, there have been significant changes in the strategy and applications for homeland security. Recently there have been significant at deterring and interdicting terrorists and associated organizations. This is a shift in the normal paradigm of deterrence and surveillance of a nation and the `conventional' methods of warfare to the `unconventional' means that terrorist organizations resort to. With that shift comes the responsibility to monitor international borders for weapons of mass destruction, including radiological weapons. As a result, countries around the world are deploying radiation detection instrumentation to interdict the illegal shipment of radioactive material crossing international borders. These efforts include deployments at land, rail, air, and sea ports of entry in the US and in European and Asian countries. Radioactive signatures of concern include radiation dispersal devices (RDD), nuclear warheads, and special nuclear material (SNM). Radiation portal monitors (RPMs) are used as the main screening tool for vehicles and cargo at borders, supplemented by handheld detectors, personal radiation detectors, and x-ray imaging systems. This talk will present an overview of radiation detection equipment with emphasis on radiation portal monitors. In the US, the deployment of radiation detection equipment is being coordinated by the Domestic Nuclear Detection Office within the Department of Homeland Security, and a brief summary of the program will be covered. Challenges with current generation systems will be discussed as well as areas of investigation and opportunities for improvements. The next generation of radiation portal monitors is being produced under the Advanced Spectroscopic Portal program and will be available for deployment in the near future. Additional technologies, from commercially available to experimental, that provide additional information for radiation screening, such as density imaging equipment, will

  20. Instrument evaluation no. 10. Scanray radiation meter type 751

    CERN Document Server

    Burgess, P H; White, D F

    1978-01-01

    The various radiations encountered in radiological protection cover a wide range of energies and radiation measurements have to be carried out under an equally broad spectrum of environmental conditions. This report is one of a series intended to give information on the performance characteristics of radiological protection instruments, to assist in the selection of appropriate instruments for a given purpose, to interpret the results obtained with such instruments, and, in particular, to know the likely sources and magnitude of errors that might be associated with measurements in the field. The radiation, electrical and environmental characteristics of radiation protection instruments are considered together with those aspects of the construction which make an instrument convenient for routine use. To provide consistent criteria for instrument performance, the range of tests performed on any particular class of instrument, the test methods and the criteria of acceptable performance are based broadly on the a...

  1. Instrument evaluation no. 33. Automess Szintomat 6134 radiation survey meter

    International Nuclear Information System (INIS)

    McClure, D.R.

    1986-04-01

    The various radiations encountered in radiological protection cover a wide range of energies and radiation measurements have to be carried out under an equally broad spectrum of environmental conditions. This report is one of a series intended to give information on the performance characteristics of radiological protection instruments, to assist in the selection of appropriate instruments for a given purpose, to interpret the results obtained with such instruments, and, in particular, to know the likely sources and magnitude of errors that might be associated with measurements in the field. The radiation, electrical and environmental characteristics of radiation protection instruments are considered together with those aspects of the construction which make an instrument convenient for routine use. To provide consistent criteria for instrument performance, the range of tests performed on any particular class of instrument, the test methods and the criteria of acceptable performance are based broadly on the appropriate Recommendations of the International Electrotechnical Commission. The radiations in the tests are, in general, selected from the range of reference radiations for instrument calibration being drawn up by the International Standards Organisation. Normally, each report deals with the capabilities and limitations of one model of instrument and no direct comparison with other instruments intended for similar purposes is made, since the significance of particular performance characteristics largely depends on the radiations and environmental conditions in which the instrument is to be used. The results quoted here have all been obtained from tests on instruments in routine production, with the appropriate measurements being made by the NRPB. This instrument evaluation report deals with the Automess Szintomat 6134 Radiation Survey Meter

  2. Radiation transmission type pipe wall thinning detection device and measuring instruments utilizing ionizing radiation

    International Nuclear Information System (INIS)

    Higashi, Yasuhiko

    2009-01-01

    We developed the device to detect thinning of pipe thorough heat insulation in Power Plant, etc, even while the plant is under operation. It is necessary to test many parts of many pipes for pipe wall thinning management, but it is difficult within a limited time of the routine test. This device consists of detector and radiation source, which can detect the pipe (less than 500 mm in external diameter, less than 50 mm in thickness) with 1.6%-reproducibility (in a few-minutes measurement), based on the attenuation rate. Operation is easy and effective without removing the heat insulation. We will expand this thinning detection system, and contribute the safety of the Plant. (author)

  3. A historical review of portable health physics instruments and their use in radiation protection programs at Hanford, 1944 through 1988

    Energy Technology Data Exchange (ETDEWEB)

    Howell, W.P.; Kenoyer, J.L.; Kress, M.L.; Swinth, K.L.; Corbit, C.D.; Zuerner, L.V.; Fleming, D.M.; DeHaven, H.W.

    1989-09-01

    This historical review covers portable health physics instruments at Hanford from an applications viewpoint. The review provides information on specific instruments and on the general kinds of facility work environments in which the instruments have been and are being used. It provides a short, modestly technical explanation of the types of nuclear radiations, the way radiation units are quantified, and the types of nuclear radiations, the way radiation units are quantified, and the types of detection media used in portable health physics instruments. This document does not, however, cover the history of the entire Hanford program that was required to develop and/or modify the subject instruments. 11 refs., 34 figs., 2 tabs.

  4. A historical review of portable health physics instruments and their use in radiation protection programs at Hanford, 1944 through 1988

    International Nuclear Information System (INIS)

    Howell, W.P.; Kenoyer, J.L.; Kress, M.L.; Swinth, K.L.; Corbit, C.D.; Zuerner, L.V.; Fleming, D.M.; DeHaven, H.W.

    1989-09-01

    This historical review covers portable health physics instruments at Hanford from an applications viewpoint. The review provides information on specific instruments and on the general kinds of facility work environments in which the instruments have been and are being used. It provides a short, modestly technical explanation of the types of nuclear radiations, the way radiation units are quantified, and the types of nuclear radiations, the way radiation units are quantified, and the types of detection media used in portable health physics instruments. This document does not, however, cover the history of the entire Hanford program that was required to develop and/or modify the subject instruments. 11 refs., 34 figs., 2 tabs

  5. Quality assurance of radiation protection monitoring instruments in India

    International Nuclear Information System (INIS)

    Tripathi, S.M.; Daniel, Liji; Rao, Suresh; Sharma, D.N.

    2008-01-01

    Bhabha Atomic Research Centre (BARC) is the National Metrology Institute (NMI) for developing, maintaining and disseminating standards for ionizing radiation in India. Radiation Safety Systems Division (RSSD) of BARC has the requisite infrastructure in the form of experts, trained manpower, laboratories, equipment and facilities for providing calibration services to users and ascertaining traceability to international standards. It periodically participates in various international inter-comparisons. RSSD maintains reference radiation fields that are required for calibrating Radiation Protection Monitoring Instruments that form the backbone of the radiation monitoring programme for harnessing the benefits of nuclear energy and ionizing radiations. These instruments are type-tested and periodically calibrated at standard reference radiation fields to ensure their healthy working condition and fitness for their intended use. This paper describes the details of the standardization procedures adopted for reference radiation fields and infrastructure established and maintained at RSSD, BARC in accordance with the recommendations of ISO-4037. The paper describes the various tests that are carried out for radiation protection monitoring instrument to study the variation of the calibration factor with influencing quantities like linearity of response, energy response, angular dependence and overload characteristics. The results of these tests for typical instruments are also discussed. The present work also describes various types of indigenously developed radiation protection monitoring instruments and their performance characteristics. Adaptability of these instruments for the implementation of operational quantities are discussed briefly. It also dwells on the IAEA Quality Audit for radiation protection level calibrations, which RSSD has been participating since 2001. Our results of the quality audit are well within the acceptance limit (±7%) set by IAEA for the

  6. Health physics instrument manual

    International Nuclear Information System (INIS)

    Gupton, E.D.

    1978-08-01

    The purpose of this manual is to provide apprentice health physics surveyors and other operating groups not directly concerned with radiation detection instruments a working knowledge of the radiation detection and measuring instruments in use at the Laboratory. The characteristics and applications of the instruments are given. Portable instruments, stationary instruments, personnel monitoring instruments, sample counters, and miscellaneous instruments are described. Also, information sheets on calibration sources, procedures, and devices are included. Gamma sources, beta sources, alpha sources, neutron sources, special sources, a gamma calibration device for badge dosimeters, and a calibration device for ionization chambers are described

  7. Detection of Terahertz Radiation

    DEFF Research Database (Denmark)

    2015-01-01

    The present invention relates to a system for detecting terahertz radiation, a camera device, and a method for detecting terahertz radiation.......The present invention relates to a system for detecting terahertz radiation, a camera device, and a method for detecting terahertz radiation....

  8. ''Cutie Pie,'' A portable radiation instrument

    International Nuclear Information System (INIS)

    Ballou, C.O.

    1947-01-01

    A portable beta and gamma radiation meter of exceedingly small dimensions and weight has been developed. User acceptance has been more enthusiastic than any previous instrument of its type. The circuit, using one Victoreen V-32 tube, is the simplest electronic circuit possible for radiation work and gives high sensitivity. Stability exceeds anything of comparable sensitivity which has come to our attention. The short term stability is due to a circuit which prevents emission before the cathode reaches operating temperature. Long term stability has been improved by evacuating the tube enclosure and switch. The complete, one unit instrument, weighs four pounds two ounces, and is carried with a pistol grip. Exclusive of chamber and handle, its dimensions are 3'' wide, 6 1/2'' long, and 5'' high. The case is formed of aluminum and is designed to give excellent visibility of the meter. Three ranges of approximately 50, 500 and 5000 mr/hr have been incorporated in the instruments. The instrument has been named ''Cutie Pie'' due to its diminutive size

  9. Radiation-hardened micro-electronics for nuclear instrumentation

    International Nuclear Information System (INIS)

    Van Uffelen, M.

    2007-01-01

    The successful development and deployment of future fission and thermonuclear fusion reactors depends to a large extent on the advances of different enabling technologies. Not only the materials need to be custom engineered but also the instrumentation, the electronics and the communication equipment need to support operation in this harsh environment, with expected radiation levels during maintenance up to several MGy. Indeed, there are yet no commercially available electronic devices available off-the-shelf which demonstrated a satisfying operation at these extremely high radiation levels. The main goal of this task is to identify commercially available radiation tolerant technologies, and to design dedicated and integrated electronic circuits, using radiation hardening techniques, both at the topological and architectural level. Within a stepwise approach, we first design circuits with discrete components and look for an equivalent integrated technology. This will enable us to develop innovative instrumentation and communication tools for the next generation of nuclear reactors, where both radiation hardening and miniaturization play a dominant role

  10. Control device intended for a gamma radiation measuring instrument

    International Nuclear Information System (INIS)

    1976-01-01

    This invention concerns a monitoring device for a gamma radiation measuring instrument or radiation meter, in which the radiation to be measured brings about, inter alia, the ionisation of a gas and the generation of current pulses. The dial of this meter is generally calibrated in roentgens per hour, i.e. in radiation rate units. This instrument of very simple design is remarkable for its operating reliability. Preferably placed at the inlet to a radioactive area, it enables every user of a ratemeter to check, over the entire measuring range of this instrument, its proper operation prior to entering the area. To this effect, the monitoring device in question has a thick wall lead castle, having an internal cavity in which is mounted a radioactive source delivering a gamma radiation with given constant characteristics, through a measurement window closed by a calibrated plug. Lead doors articulated on the castle can be superimposed on this window to bring about a given attenuation of the radiation coming from the source and delivered to the exterior of the castle [fr

  11. Radiation detection technology assessment program (RADTAP)

    International Nuclear Information System (INIS)

    Smith, D.E.

    1998-01-01

    The U.S. Customs Service and the U.S. Department of Energy (DOE) conducted a technical and operational assessment of gamma ray radiation detection equipment during the period May 5-16, 1997 at a testing facility in North Carolina. The effort was entitled, ''Radiation Detection Technology Assessment Program (RADTAP)'', and was conducted for the purpose of assessing the applicability, sensitivity and robustness of a diverse suite of gamma ray detection and identification equipment for possible use by Customs and other law enforcement agencies. Thirteen companies entered 25 instruments into the assessment program. All detection equipment entered had to exhibit a minimum sensitivity of 20 micro-R per hour (background included) from a Cesium-137 point source. Isotope identifying spectrometers entered were man portable and operable at room temperature with read-out that could be interpreted by non-technical personnel. Radioactive sources used in the assessment included special nuclear material, industrial and health isotopes. Evaluators included Customs inspectors and technical experts from DOE and Customs. No conclusions or recommendations were issued based on the quantitative and qualitative test results, however, the results of the program provided law enforcement agencies with the necessary data to select equipment that best meets their operational needs and budgets. (author)

  12. Survey of instrumentation for environmental monitoring: major update. Volume 3. Radiation

    Energy Technology Data Exchange (ETDEWEB)

    1979-09-01

    This is the third volume of a four-volume (seven-part) series, the culmination of a comprehensive survey of instrumentation for environmental monitoring. Consideration is given to instruments and techniques presently in use and to those developed for other purposes but having possible applications to radiation monitoring. The results of the survey are given as descriptions of the physical and operating characteristics of available instruments, critical comparisons among instrumentation methods, and recommendations of promising methodology and development of new instrumentation. Information is also given regarding the pollutants to be monitored, their characteristics and forms, their sources and pathways, their effects on the ecosystem, and the means of controlling them through process and regulatory controls. The discussion is presented under sections entitled radiation sources; instrumentation: by type of radiation or instrument type; and, instrumentation for specific radionuclides. (JGB)

  13. Survey of instrumentation for environmental monitoring: major update. Volume 3. Radiation

    International Nuclear Information System (INIS)

    1979-09-01

    This is the third volume of a four-volume (seven-part) series, the culmination of a comprehensive survey of instrumentation for environmental monitoring. Consideration is given to instruments and techniques presently in use and to those developed for other purposes but having possible applications to radiation monitoring. The results of the survey are given as descriptions of the physical and operating characteristics of available instruments, critical comparisons among instrumentation methods, and recommendations of promising methodology and development of new instrumentation. Information is also given regarding the pollutants to be monitored, their characteristics and forms, their sources and pathways, their effects on the ecosystem, and the means of controlling them through process and regulatory controls. The discussion is presented under sections entitled radiation sources; instrumentation: by type of radiation or instrument type; and, instrumentation for specific radionuclides

  14. Application of single-chip microcomputer in radiation detection

    International Nuclear Information System (INIS)

    Zhang Songshou

    1993-01-01

    The single-chip microcomputer has some advantages in many aspects for example the strong function, the small volume, the low-power, firmed and reliable. It is used widely in the control of industry, instrument, communication and machine, etc.. The paper introduces that the single-chip microcomputer is used in radiation detection, mostly including the use of control, linear, compensation, calculation, prefabricated change, improving precision and training

  15. Portable radiation instrumentation traceability of standards and measurements

    International Nuclear Information System (INIS)

    Wiserman, A.; Walke, M.

    1995-01-01

    Portable radiation measuring instruments are used to estimate and control doses for workers. Calibration of these instruments must be sufficiently accurate to ensure that administrative and legal dose limits are not likely to be exceeded due to measurement uncertainties. An instrument calibration and management program is established which permits measurements made with an instrument to be traced to a national standard. This paper describes the establishment and maintenance of calibration standards for gamma survey instruments and an instrument management program which achieves traceability of measurement for uniquely identified field instruments. (author)

  16. INSTRUMENTATION FOR MEASURING AND TRANSMISSION THE SOLAR RADIATION THROUGH EARTH’S ATMOSPHERE

    Directory of Open Access Journals (Sweden)

    Alexandru Dan Toma

    2013-07-01

    Full Text Available The Sun's energy is distributed over a broad range of the electromagnetic spectrum and Sun behaves approximately like a "blackbody" radiating at a temperature of about 5800 K with maximum output in the green-yellow part of the visible spectrum, around 500 nm. Not all solar radiation reaching the top of the atmosphere reaches Earth's surface due to a various optical phenomena in regard to solar radiation crossing the Earth’s atmosphere. In order to investigate them, there are two general categories of instruments used to measure the transmission of solar radiation through Earth's atmosphere: instruments that measure radiation from the entire sky and instruments that measure only direct solar radiation. Within each of these categories, instruments can be further subdivided into those that measure radiation over a broad range of wavelengths and those that measure only specific wavelengths.

  17. MGR COMPLIANCE PROGRAM GUIDANCE PACKAGE FOR RADIATION PROTECTION EQUIPMENT, INSTRUMENTATION, AND FACILITIES

    International Nuclear Information System (INIS)

    2000-01-01

    This Compliance Program Guidance Package identifies the regulatory guidance and industry codes and standards addressing radiation protection equipment, instrumentation, and support facilities considered to be appropriate for radiation protection at the Monitored Geologic Repository (MGR). Included are considerations relevant to radiation monitoring instruments, calibration, contamination control and decontamination, respiratory protection equipment, and general radiation protection facilities. The scope of this Guidance Package does not include design guidance relevant to criticality monitoring, area radiation monitoring, effluent monitoring, and airborne radioactivity monitoring systems since they are considered to be the topics of specific design and construction requirements (i.e., ''fixed'' or ''built-in'' systems). This Guidance Package does not address radiation protection design issues; it addresses the selection and calibration of radiation monitoring instrumentation to the extent that the guidance is relevant to the operational radiation protection program. Radon and radon progeny monitoring instrumentation is not included in the Guidance Package since such naturally occurring radioactive materials do not fall within the NRC's jurisdiction at the MGR

  18. The introduction of radiation monitor produced by several nuclear instrument factories

    International Nuclear Information System (INIS)

    Yu Liying

    2005-01-01

    The paper introduce some radiation monitor products of several nuclear instrument factories include Xi'an Nuclear Instrument Factory, MGP Instruments Inc, and Canberra Industries Inc. The introduction aspects include the range, configuration, and application of products. So, the paper is reference for the designer with responsibility for radiation monitoring system of new nuclear project. (authors)

  19. Radiation detection device and a radiation detection method

    International Nuclear Information System (INIS)

    Blum, A.

    1975-01-01

    A radiation detection device is described including at least one scintillator in the path of radiation emissions from a distributed radiation source; a plurality of photodetectors for viewing each scintillator; a signal processing means, a storage means, and a data processing means that are interconnected with one another and connected to said photodetectors; and display means connected to the data processing means to locate a plurality of radiation sources in said distributed radiation source and to provide an image of the distributed radiation sources. The storage means includes radiation emission response data and location data from a plurality of known locations for use by the data processing means to derive a more accurate image by comparison of radiation responses from known locations with radiation responses from unknown locations. (auth)

  20. Legal verification of the dosimetric instrumentation using for radiation protection in Cuba

    International Nuclear Information System (INIS)

    Walwyn, A.; Morales, J.A.

    1999-01-01

    By April of 1998 the Decree law 183 of Metrology was published at the Gaceta Oficial de la Republica de Cuba. It establishes the principles and general regulations for the organisation and juridical system of the metrological activity in Cuba. In the radiation protection field this legislation promote the establishment of a verification service of radiation measuring instruments used in the practices with radiation sources in the country. The limitations of old Cuban standards of verification related to dosimetric quantities and to the types of instruments for those which these standards are applicable; and in addition, the publication of new international standards that includes the operational quantities used for the measurement of instruments, led to the elaboration of the X and Gamma Radiation Meters Used in Radiation Protection standard. The requirements of metrological aptitude are taken from some test procedures described in the International Electrotechnical Commission (IEC) standards on photon monitoring equipment. The Secondary Standard Dosimetry Laboratory of the Centre for Radiation Protection and Higiene will start the verification service of Radiation Protection instruments. The beginning of the service is an essential element in the improvement of the accuracy of ionisation radiation metrology in Cuba, and have an evident impact in the protection of the occupationally exposed workers, because having the instruments in good technical condition became a legal exigency to the users of ionisation radiation

  1. Calibration methodology for instruments utilized in X radiation beams, diagnostic level

    International Nuclear Information System (INIS)

    Penha, M. da; Potiens, A.; Caldas, L.V.E.

    2004-01-01

    Methodologies for the calibration of diagnostic radiology instruments were established at the Calibration Laboratory of IPEN. The methods may be used in the calibration procedures of survey meters used in radiation protection measurements (scattered radiation), instruments used in direct beams (attenuated and non attenuated beams) and quality control instruments. The established qualities are recommended by the international standards IEC 1267 and ISO 4037-3. Two ionization chambers were used as reference systems, one with a volume of 30 cm 3 for radiation protection measurements, and the other with a volume of 1 cm 3 for direct beam measurements. Both are traceable to the German Primary Laboratory of Physikalisch-Technische Bundesanstalt (PTB). In the case of calibration of quality control instruments, a non-invasive method using the measurement of the spectrum endpoint was established with a portable gamma and X-ray Intertechnique spectrometer system. The methods were applied to survey meters (radiation protection measurements), ionization chambers (direct beam measurements) and k Vp meters (invasive and non-invasive instruments). (Author)

  2. Calibration methodology for instruments utilized in X radiation beams, diagnostic level

    Energy Technology Data Exchange (ETDEWEB)

    Penha, M. da; Potiens, A.; Caldas, L.V.E. [Instituto de Pesquisas Energeticas e Nucleares, Comissao Nacional de Energia Nuclear, Sao Paulo (Brazil)]. E-mail: mppalbu@ipen.br

    2004-07-01

    Methodologies for the calibration of diagnostic radiology instruments were established at the Calibration Laboratory of IPEN. The methods may be used in the calibration procedures of survey meters used in radiation protection measurements (scattered radiation), instruments used in direct beams (attenuated and non attenuated beams) and quality control instruments. The established qualities are recommended by the international standards IEC 1267 and ISO 4037-3. Two ionization chambers were used as reference systems, one with a volume of 30 cm{sup 3} for radiation protection measurements, and the other with a volume of 1 cm{sup 3} for direct beam measurements. Both are traceable to the German Primary Laboratory of Physikalisch-Technische Bundesanstalt (PTB). In the case of calibration of quality control instruments, a non-invasive method using the measurement of the spectrum endpoint was established with a portable gamma and X-ray Intertechnique spectrometer system. The methods were applied to survey meters (radiation protection measurements), ionization chambers (direct beam measurements) and k Vp meters (invasive and non-invasive instruments). (Author)

  3. Analysis on detection accuracy of binocular photoelectric instrument optical axis parallelism digital calibration instrument

    Science.gov (United States)

    Ying, Jia-ju; Yin, Jian-ling; Wu, Dong-sheng; Liu, Jie; Chen, Yu-dan

    2017-11-01

    Low-light level night vision device and thermal infrared imaging binocular photoelectric instrument are used widely. The maladjustment of binocular instrument ocular axises parallelism will cause the observer the symptom such as dizziness, nausea, when use for a long time. Binocular photoelectric equipment digital calibration instrument is developed for detecting ocular axises parallelism. And the quantitative value of optical axis deviation can be quantitatively measured. As a testing instrument, the precision must be much higher than the standard of test instrument. Analyzes the factors that influence the accuracy of detection. Factors exist in each testing process link which affect the precision of the detecting instrument. They can be divided into two categories, one category is factors which directly affect the position of reticle image, the other category is factors which affect the calculation the center of reticle image. And the Synthesize error is calculated out. And further distribute the errors reasonably to ensure the accuracy of calibration instruments.

  4. New instruments for radiation protection

    International Nuclear Information System (INIS)

    Bartos, D.; Ciobanu, M.; Constantin, F.; Petcu, M.; Plostinaru, V.D.; Rusu, Al.; Lupu, A.C.; Lupu, F.

    2003-01-01

    Though a century old, the radiation protection is actual by its purpose: a dose as low as reasonable achievable is to be received either by involved professionals or population. This threshold is dependent on the technical progress. Some major developments like surface mounted device technology, consumer almost ideal operational amplifiers, microcontrollers and the news signal digital processing techniques, offer the opportunity to design improved instruments for radioprotection. To put in a light portable instrument both the whole measuring system and the 'intelligence' - a microcontroller and the associated software - are the main ideas applied by the authors. The result is presented: a family of eight members, at least, based on two parents. (authors)

  5. Design and development of an instrument to measure radiative absorption of seawater. Sumarad

    International Nuclear Information System (INIS)

    Fasano, G.; Materassi, A.

    2003-01-01

    In the present work, a low-cost instrument is presented that provides the ratio between underwater radiation and radiation outside water for the four spectral ranges fundamental for photosynthetic activity (Sub Marine Radiometer). The instrument essentially consists of two radiometers which operate in the same four bands: one acquires radiation outside the water, the other underwater radiation at a pre-established depth. The two acquisition systems are synchronized when the instrument is turned on and then, in the course of data elaboration, the ratio is obtained between underwater and outside water radiation for each spectral band, at any determined moment, at a predetermined depth. This ratio, in accordance with the Beer-Lambert equation, represents the transmittance of the medium crossed by radiation. By applying the Linke equation to collected data, it is also possible to determine the turbidity of the considered medium. The system can acquire as many as 1,472 data, with programmable temporal scanning, and can operate at depths up to 50 meters. Applications of this instrument are already in progress in studies concerning the relationship between solar radiation and photosynthetic activity of Posidonia oceanica. The proposed instrument has a relatively low cost, when compared with that of other instruments currently on the market, making it particularly suitable for applications that require numerous instruments to monitor sea, lacustrine or fluvial water in various points at the same time [it

  6. Gadolinium for neutron detection in current nuclear instrumentation research: A review

    Science.gov (United States)

    Dumazert, J.; Coulon, R.; Lecomte, Q.; Bertrand, G. H. V.; Hamel, M.

    2018-02-01

    Natural gadolinium displays a number of remarkable physical properties: it is a rare earth element, composed of seven stable or quasi-stable isotopes, with an exceptionally high magnetization and a Curie point near room temperature. Its use in the field of nuclear instrumentation historically relates to its efficiency as a neutron poison in power reactors. Gadolinium is indeed the naturally occurring element with the highest interaction probability with neutrons at thermal energy, shared between Gd-157 (15.65%, 254000 b cross section) and Gd-155 (14.8%, 60900 b) isotopes. Considering that neutron capture results in an isotopic change, followed by a radiative rearrangement of nuclear and atomic structures, Gd may be embodied not merely as a neutron poison but as a neutron converter into a prompt photon and an electron source term. Depending on the nature and energy of the reaction products (from a few-keV Auger electrons up to 8 MeV gamma rays) that the detector aims at isolating as an indirect neutron signature, a variety of sensor media and counting methods have been introduced during the last decades. This review first draws a theoretical description of the radiative cascade following Gd(n , γ) capture. The cascade may be subdivided into regions of interest, each corresponding to dedicated detection designs and optimizations whose current status is detailed. This inventory has allowed the authors to extract and benchmark key figures of merit for the definition of a detection scheme: neutron attenuation, neutron sensitivity (cps/nv), gamma rejection, neutron detection limit in a mixed field, intrinsic or extrinsic moderation, and transportability. On this basis, the authors have identified promising paths for Gd-based neutron detection in contemporary instrumentation.

  7. Indirect detection of radiation sources through direct detection of radiolysis products

    Science.gov (United States)

    Farmer, Joseph C [Tracy, CA; Fischer, Larry E [Los Gatos, CA; Felter, Thomas E [Livermore, CA

    2010-04-20

    A system for indirectly detecting a radiation source by directly detecting radiolytic products. The radiation source emits radiation and the radiation produces the radiolytic products. A fluid is positioned to receive the radiation from the radiation source. When the fluid is irradiated, radiolytic products are produced. By directly detecting the radiolytic products, the radiation source is detected.

  8. Performance test of SKIROC II ASIC chip for the radiation detection

    Energy Technology Data Exchange (ETDEWEB)

    Jun, W. J.; Namgoong, H.; Kim, B. K.; Song, H. S.; Kim, H. S.; Lee, S. H.; Choi, H. J.; Ghergherehchi, M.; Chai, J. S. [Sungkyunkwan University, Suwon (Korea, Republic of)

    2017-04-15

    There is a PCB board called FEV8 board which can readout analog signal from any energy source, and amplify it for signal processing. For precise detection, the board had been designed to operate in wide range of energy condition, with high-resolutive detection performance. This function has the possibility of the utilization for the radiation detection. The channels of the prototype board must be evaluated to make sure that the board is perfect or not. This research had made an progress for the radiation detection as well as the electronics of the intricate combination of the measurement instrumentations. The number of the noisy channels had been measured for threshold scan, and every channels in the board had been evaluated. By improving the experimental conditions such as test script in Linux system or well designed ground condition of the test bench, much more clean data will be able to be acquisited.

  9. Standards for radiation protection instrumentation: design of safety standards and testing procedures

    International Nuclear Information System (INIS)

    Meissner, Frank

    2008-01-01

    This paper describes by means of examples the role of safety standards for radiation protection and the testing and qualification procedures. The development and qualification of radiation protection instrumentation is a significant part of the work of TUV NORD SysTec, an independent expert organisation in Germany. The German Nuclear Safety Standards Commission (KTA) establishes regulations in the field of nuclear safety. The examples presented may be of importance for governments and nuclear safety authorities, for nuclear operators and for manufacturers worldwide. They demonstrate the advantage of standards in the design of radiation protection instrumentation for new power plants, in the upgrade of existing instrumentation to nuclear safety standards or in the application of safety standards to newly developed equipment. Furthermore, they show how authorities may proceed when safety standards for radiation protection instrumentation are not yet established or require actualization. (author)

  10. Design of instrument for monitoring nuclear radiation and baneful gas

    International Nuclear Information System (INIS)

    Xiong Jianping; Chen Jun; Zhu Wenkai

    2006-01-01

    Counters and ionization chambers are applied to sensors, and microprocessor based on ARM IP is applied to center controller in the instrument. It is achieved to monitor nuclear radiation and baneful gas in an instrument. The instrument is capable of LCD displaying, menu operating and speech alarming. (authors)

  11. The geostationary Earth radiation budget (GERB) instrument on EUMETSAT's MSG satellite

    Science.gov (United States)

    Sandford, M. C. W.; Allan, P. M.; Caldwell, M. E.; Delderfield, J.; Oliver, M. B.; Sawyer, E.; Harries, J. E.; Ashmall, J.; Brindley, H.; Kellock, S.; Mossavati, R.; Wrigley, R.; Llewellyn-Jones, D.; Blake, O.; Butcher, G.; Cole, R.; Nelms, N.; DeWitte, S.; Gloesener, P.; Fabbrizzi, F.

    2003-12-01

    Geostationary Earth radiation budget (GERB) is an Announcement of Opportunity Instrument for EUMETSAT's Meteosat Second Generation (MSG) satellite. GERB will make accurate measurements of the Earth Radiation Budget from geostationary orbit, provide an absolute reference calibration for LEO Earth radiation budget instruments and allow studies of the energetics of atmospheric processes. By operating from geostationary orbit, measurements may be made many times a day, thereby providing essentially perfect diurnal sampling of the radiation balance between reflected and emitted radiance for that area of the globe within the field of view. GERB will thus complement other instruments which operate in low orbit and give complete global coverage, but with poor and biased time resolution. GERB measures infrared radiation in two wavelength bands: 0.32-4.0 and 0.32- 30 μm, with a pixel element size of 44 km at sub-satellite point. This paper gives an overview of the project and concentrates on the design and development of the instrument and ground testing and calibration, and lessons learnt from a short time scale low-budget project. The instrument was delivered for integration on the MSG platform in April 1999 ready for the proposed launch in October 2000, which has now been delayed probably to early 2002. The ground segment is being undertaken by RAL and RMIB and produces near real-time data for meteorological applications in conjunction with the main MSG imager—SEVERI. Climate research and other applications which are being developed under a EU Framework IV pilot project will be served by fully processed data. Because of the relevance of the observations to climate change, it is planned to maintain an operating instrument in orbit for at least 3.5 years. Two further GERB instruments are being built for subsequent launches of MSG.

  12. Semiconductor radiation detection systems

    CERN Document Server

    2010-01-01

    Covers research in semiconductor detector and integrated circuit design in the context of medical imaging using ionizing radiation. This book explores other applications of semiconductor radiation detection systems in security applications such as luggage scanning, dirty bomb detection and border control.

  13. Single-chip microcomputer application in nuclear radiation monitoring instruments

    International Nuclear Information System (INIS)

    Zhang Songshou

    1994-01-01

    The single-chip microcomputer has advantage in many respects i.e. multiple function, small size, low-power consumption,reliability etc. It is widely used now in industry, instrumentation, communication and machinery. The author introduced usage of single-chip microcomputer in nuclear radiation monitoring instruments for control, linear compensation, calculation, changeable parameter presetting and military training

  14. APPLICATION OF THE SPECTROMETRIC METHOD FOR CALCULATING THE DOSE RATE FOR CREATING CALIBRATION HIGHLY SENSITIVE INSTRUMENTS BASED ON SCINTILLATION DETECTION UNITS

    Directory of Open Access Journals (Sweden)

    R. V. Lukashevich

    2017-01-01

    Full Text Available Devices based on scintillation detector are highly sensitive to photon radiation and are widely used to measure the environment dose rate. Modernization of the measuring path to minimize the error in measuring the response of the detector to gamma radiation has already reached its technological ceiling and does not give the proper effect. More promising for this purpose are new methods of processing the obtained spectrometric information. The purpose of this work is the development of highly sensitive instruments based on scintillation detection units using a spectrometric method for calculating dose rate.In this paper we consider the spectrometric method of dosimetry of gamma radiation based on the transformation of the measured instrumental spectrum. Using predetermined or measured functions of the detector response to the action of gamma radiation of a given energy and flux density, a certain function of the energy G(E is determined. Using this function as the core of the integral transformation from the field to dose characteristic, it is possible to obtain the dose value directly from the current instrumentation spectrum. Applying the function G(E to the energy distribution of the fluence of photon radiation in the environment, the total dose rate can be determined without information on the distribution of radioisotopes in the environment.To determine G(E by Monte-Carlo method instrumental response function of the scintillator detector to monoenergetic photon radiation sources as well as other characteristics are calculated. Then the whole full-scale energy range is divided into energy ranges for which the function G(E is calculated using a linear interpolation.Spectrometric method for dose calculation using the function G(E, which allows the use of scintillation detection units for a wide range of dosimetry applications is considered in the article. As well as describes the method of calculating this function by using Monte-Carlo methods

  15. Radiation monitors of new generation - New methodology of detection of nuclear and radioactive materials

    International Nuclear Information System (INIS)

    Kagan, L.; Stavrov, A.

    2001-01-01

    Full text: In recent few years the world community has faced a problem which was considered before as an almost theoretical one - a possibility of illicit trafficking of nuclear and radioactive materials due to their partially controlled or even completely uncontrolled proliferation. Organization of the first conference entitled 'Safety of Radiation Sources and Security of Radioactive Materials', Dijon, France, 14-18 September 1998, is particularly a witness of the world community's concern about these issues. The conference was held under the aegis of the IAEA, European Commission, INTERPOL and World Customs Organization. The conference covered the whole range of problems concerned with both the elaboration of legal regulations of radiation control, development of equipment and training of personnel. Since 1997 till 2000 the international ITRAP program (Illicit Trafficking Radiation Detection Assessment Program) was held under the aegis of the IAEA, WCO and INTERPOL. The task of the program was to work out the common requirements to the equipment, to test the equipment against the program requirements and to elaborate recommendations for the IAEA member-countries. In the course of this program realization the modern devices of the world leading manufacturers of the equipment for radiation control at state borders had been tested. The equipment to be tested is designed to fulfil the following main tasks: alarming about the presence of radioactive source in the controlled area; detection and location of the source, as well as its identification, personnel radiation protection being necessarily provided. To fulfil each of the above tasks essentially different specialized instruments are used: from large fixed installed systems to portable instruments, 'pager' type pocket search instruments and personal dosimeters. Consequently numerous different instruments have to be used during the radiation control at borders. It creates considerable difficulties for border guard

  16. Synchrotron radiation microtomography of musical instruments: a non-destructive monitoring technique for insect infestations

    Directory of Open Access Journals (Sweden)

    Beatrice Bentivoglio-Ravasio

    2011-08-01

    Full Text Available X-ray computed tomography is becoming a common technique for the structural analysis of samples of cultural relevance, providing luthiers, art historians, conservators and restorators with a unique tool for the characterization of musical instruments. Synchrotron-radiation phase-contrast microtomography is an ideal technique for the non-destructive 3D analysis of samples where small lowabsorbing details such as larvae and eggs can be detected. We report results from the first feasibility studies performed at the Elettra synchrotron laboratory, where the 1494 organ by Lorenzo Gusnasco da Pavia has been studied. Together with important information about the structural conditions, the presence of xylophages could be detected and characterized.

  17. Radiation Budget Instrument (RBI) for JPSS-2

    Science.gov (United States)

    Georgieva, Elena; Priestley, Kory; Dunn, Barry; Cageao, Richard; Barki, Anum; Osmundsen, Jim; Turczynski, Craig; Abedin, Nurul

    2015-01-01

    Radiation Budget Instrument (RBI) will be one of five instruments flying aboard the JPSS-2 spacecraft, a polar-orbiting sun-synchronous satellite in Low Earth Orbit. RBI is a passive remote sensing instrument that will follow the successful legacy of the Clouds and Earth's Radiant Energy System (CERES) instruments to make measurement of Earth's short and longwave radiation budget. The goal of RBI is to provide an independent measurement of the broadband reflected solar radiance and Earth's emitted thermal radiance by using three spectral bands (Shortwave, Longwave, and Total) that will have the same overlapped point spread function (PSF) footprint on Earth. To ensure precise NIST-traceable calibration in space the RBI sensor is designed to use a visible calibration target (VCT), a solar calibration target (SCT), and an infrared calibration target (ICT) containing phase change cells (PCC) to enable on-board temperature calibration. The VCT is a thermally controlled integrating sphere with space grade Spectralon covering the inner surface. Two sides of the sphere will have fiber-coupled laser diodes in the UV to IR wavelength region. An electrical substitution radiometer on the integrating sphere will monitor the long term stability of the sources and the possible degradation of the Spectralon in space. In addition the radiometric calibration operations will use the Spectralon diffusers of the SCT to provide accurate measurements of Solar degradation. All those stable on-orbit references will ensure that calibration stability is maintained over the RBI sensor lifetime. For the preflight calibration the RBI will view five calibration sources - two integrating spheres and three CrIS (Cross-track Infrared Sounder ) -like blackbodies whose outputs will be validated with NIST calibration approach. Thermopile are the selected detectors for the RBI. The sensor has a requirement to perform lunar calibration in addition to solar calibration in space in a way similar to CERES

  18. Method and apparatus for continuous fluid leak monitoring and detection in analytical instruments and instrument systems

    Science.gov (United States)

    Weitz, Karl K [Pasco, WA; Moore, Ronald J [West Richland, WA

    2010-07-13

    A method and device are disclosed that provide for detection of fluid leaks in analytical instruments and instrument systems. The leak detection device includes a collection tube, a fluid absorbing material, and a circuit that electrically couples to an indicator device. When assembled, the leak detection device detects and monitors for fluid leaks, providing a preselected response in conjunction with the indicator device when contacted by a fluid.

  19. Calibration of radiation protection area monitoring instruments in Sudan

    International Nuclear Information System (INIS)

    Suliman, I.I.; Youssif, B.E.; Beineen, A.A.; Hassan, M.

    2010-01-01

    This article presents results of measurements for the calibration of radiation protection area monitoring instruments carried out during the period 2006-2008 at Secondary Standard Dosimetry Laboratory of Sudan. The work performed included quality assurance measurements, measurements for the dosimeter calibrations and uncertainty analysis. Calibrations were performed using 137 Cs gamma ray sources produced by OB 85 and OB 34/1 gamma calibrators producing air kerma rate that ranged from 10 μGy/h to 50 mGy/h. Area monitoring instruments were calibrated in terms of ambient dose equivalent, H*(10) derived using air kerma to ambient dose equivalent conversion coefficients. Results are presented for 78 area monitoring instruments representing most commonly used types in Sudan. Radioactive check source measurements for the reference chamber showed deviation within 1% limit. The accuracy in the beam output measurements was within 5% internationally considered as acceptable. The results highlighted the importance of radiation protection calibrations. Regulations are further need to ensure safety aspect really meet the required international standards.

  20. Proceedings of the workshop on radiation survey instruments and calibrations

    International Nuclear Information System (INIS)

    Selby, J.M.; Swinth, K.L.; Vallario, E.J.; Murphy, B.L.

    1985-11-01

    The workshop was held to discuss two topics: first, a performance standard for radiation survey instruments and the potential for a testing program based on that standard; and second, a system of secondary standards laboratories to provide instrument calibrations and related services. Separate abstracts have been prepared for the individual presentations

  1. Radiation detection systems

    International Nuclear Information System (INIS)

    Rozsa, Sandor

    1989-01-01

    Principles and operation of radiation detectors used for industrial and laboratory radiometric measurements are reviewed. The discussed detector types are as follows: ionization chamber, proportional counter, Geiger-Mueller counter, semiconductor detectors, scintillation counter and scintillators, photomultiplier tube, scintillation spectrometer and scintillation detector with semiconductor light sensor. A brief overview of the detectors of industrial nuclear instruments is also presented. (R.P.) 32 figs.; 3 tabs

  2. Radiation Detection Center on the Front Lines

    International Nuclear Information System (INIS)

    Hazi, A

    2005-01-01

    Many of today's radiation detection tools were developed in the 1960s. For years, the Laboratory's expertise in radiation detection resided mostly within its nuclear test program. When nuclear testing was halted in the 1990s, many of Livermore's radiation detection experts were dispersed to other parts of the Laboratory, including the directorates of Chemistry and Materials Science (CMS); Physics and Advanced Technologies (PAT); Defense and Nuclear Technologies (DNT); and Nonproliferation, Arms Control, and International Security (NAI). The RDC-- was formed to maximize the benefit of radiation detection technologies being developed in 15 to 20 research and development (R and D) programs. These efforts involve more than 200 Laboratory employees across eight directorates, in areas that range from electronics to computer simulations. The RDC's primary focus is the detection, identification, and analysis of nuclear materials and weapons. A newly formed outreach program within the RDC-- is responsible for conducting radiation detection workshops and seminars across the country and for coordinating university student internships. Simon Labov, director of the RDC, says, ''Virtually all of the Laboratory's programs use radiation detection devices in some way. For example, DNT uses radiation detection to create radiographs for their work in stockpile stewardship and in diagnosing explosives; CMS uses it to develop technology for advancing the detection, diagnosis, and treatment of cancer; and the Energy and Environment Directorate uses radiation detection in the Marshall Islands to monitor the aftermath of nuclear testing in the Pacific. In the future, the National Ignition Facility will use radiation detection to probe laser targets and study shock dynamics.''

  3. Gas Detection Instrument Based on Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    ANSONG FENG

    2013-06-01

    Full Text Available The wireless sensor network is used to simulate poisonous gas generating system in the Fire-Fighting Simulated Training System. In the paper, we use the wireless signal to simulate the poisonous gas source and use received signal strength indicator (RSSI to simulate the distance between the fireman and the gas source. The gas detection instrument samples the temperature and sphygmus of the trainee and uses the wireless signal as poisonous gas signal. When the trainee enters into the poisonous gas area, the gas detection instrument warns with sound and light and sends the type, density value, the location of the poisonous gas and vital signs of the trainee to host. The paper discusses the software and hardware design of the gas detection instrument. The system has been used to the several of Fire-Fighting training systems.

  4. Counterbalanced radiation detection system

    International Nuclear Information System (INIS)

    Platz, W.

    1987-01-01

    A counterbalanced radiation detection system is described comprising: (a) a stand; (b) a first radiation detector; (c) a first radiation detector arm means for tiltably connecting the first radiation detector with the stand; (d) a second radiation detector; (e) a second radiation detector arm means for tiltably connecting the second radiation detector with the stand, whereby the tilting angles of the radiation detector arm means define a distance between the radiation detectors; and (f) a torque transforming means connected between the first and second radiation detector arm means for transforming the torque created by one of the radiation detectors in a sense opposed to the torque created by the other radiation detector

  5. Field experience in use of radiation instruments in Cirus reactor

    International Nuclear Information System (INIS)

    Ramesh, N.; Sharma, R.C.; Agarwal, S.K.; Sawant, D.K.; Yadav, R.K.B.; Prasad, S.K.

    2005-01-01

    Cirus, located at Bhabha Atomic Research Centre, is a 40 MW (Th) research reactor fuelled by natural uranium, moderated by heavy water and cooled by de-mineralized light water. Graphite is used as reflector in this reactor. The reactor, commissioned in the year 1960, was in operation with availability factor of about 70% till early nineties. There after signs of ageing started surfacing up. After ageing studies, refurbishment plan was finalized and executed during the period from 1997-2002. after successful refurbishment, the reactor is in operation at full power. A wide range of radiation instruments have been used at Cirus for online monitoring of the radiological status of various process systems and environmental releases. Also, variety of survey meters, counting systems and monitors have been used by the health physics unit of the reactor for radiation hazard control. Many of these instruments, which were originally of Canadian design, have undergone changes due to obsolescence or as part of upgradation. This paper describes the experience with the radiation instruments of Cirus, bringing out their effectiveness in meeting the design intent, difficulties faced in their field use, and modifications carried out based on the performance feed back. Also, this paper highlights the areas where further efforts are needed to develop nuclear instrumentation to further strengthen monitoring and surveillance. (author)

  6. Detection of nuclear radiations

    International Nuclear Information System (INIS)

    Tanarro Sanz, A.

    1967-01-01

    A summary of the lectures about the ordinary detectors of nuclear radiations explained by the author in the courses of Nuclear Engineering held at the J.E.N. up to the date of publication is given. Those lectures are considered to be a necessary introduction to Nuclear Instrumentation and Applied Electronics to Nuclear Engineering so it has been intended to underline those characteristics of radiation detectors that must be taken in consideration in choosing or designing the electronic equipment associated to them in order to take advantage of each detector possibilities. (Author)

  7. Detection of nuclear radiations

    International Nuclear Information System (INIS)

    Tanarro Sanz, A.

    1959-01-01

    A summary of the lectures about the ordinary detectors of nuclear radiations given by the author in the Courses of Introduction to Nuclear Engineering held at the JEN up to the date of publication is given. Those lectures are considered to be a necessary introduction to Nuclear Instrumentation and Applied electronics to Nuclear Engineering so it has been intent to underline those characteristics of radiation detectors that must be taken in consideration in choosing or designing the electronic equipment associated to them in order to take advantage of each detector possibilities. (Author) 8 refs

  8. Recent developments in radiation detectors and instruments

    International Nuclear Information System (INIS)

    Das, Debashis

    2016-01-01

    Radiation detector is the key component in precise and accurate measurement of the nuclear radiations. The detectors deployed for radiation measurements in broadly classified sectors of Energy, Security, Discovery Science and Health and Environments are in general specific to their applications. The nuclear reactors as well as the fuel processing including waste management in energy sector require wide range/variety of detectors and the instruments for safe and precise generation of power. The security sector has gained importance in radiation monitoring in the present security perspective and there are many challenges in development of detector technology. The Discovery Science or the mega science projects viz CERN, Fermilab, GANIL, INO, MACE telescope, ITER etc have continuously generated new demand on detector related technologies that have been also found to be useful in other applications. Similarly, the health and environment monitoring have been also evolving with new technologies and techniques to address the requirement's arising in projects of new nuclear programs

  9. Paper on operation and maintenance experiences on radiation monitoring instrumentation at NAPS

    International Nuclear Information System (INIS)

    Gupta, J.P.; Vinod Kumar; Sen, S.K.; Malhotra, S.

    2005-01-01

    Narora Atomic Power Station (NAPS) is the first standardized Pressurised Heavy Water Reactor in India commissioned in the year 1989. Many new Radiation Monitoring Systems like Portal Monitors and Ventilation Exhaust Activity Monitors were first time introduced at NAPS. All the Personnel Contamination Monitors and Area Radiation Monitors used at NAPS were designed and developed by Electronics Division, BARC. Only the Portal Monitor was supplied by M/S Herfurth, Germany. The paper highlights the operation and maintenance experiences on Radiation Monitoring Instrumentation at NAPS in the last 15 years of operation. The paper also highlights the different problems faced in Radiation Instruments and our suggestions for improvement in their design for their better availability and long term reliability. (author)

  10. Bubble Radiation Detection: Current and Future Capability

    International Nuclear Information System (INIS)

    Peurrung, A.J.; Craig, R.A.

    1999-01-01

    Despite a number of noteworthy achievements in other fields, superheated droplet detectors (SDDs) and bubble chambers (BCs) have not been used for nuclear nonproliferation and arms control. This report examines these two radiation-detection technologies in detail and answers the question of how they can be or should be ''adapted'' for use in national security applications. These technologies involve closely related approaches to radiation detection in which an energetic charged particle deposits sufficient energy to initiate the process of bubble nucleation in a superheated fluid. These detectors offer complete gamma-ray insensitivity when used to detect neutrons. They also provide controllable neutron-energy thresholds and excellent position resolution. SDDs are extraordinarily simple and inexpensive. BCs offer the promise of very high efficiency (∼75%). A notable drawback for both technologies is temperature sensitivity. As a result of this problem, the temperature must be controlled whenever high accuracy is required, or harsh environmental conditions are encountered. The primary findings of this work are listed and briefly summarized below: (1) SDDs are ready to function as electronics-free neutron detectors on demand for arms-control applications. The elimination of electronics at the weapon's location greatly eases the negotiability of radiation-detection technologies in general. (2) As a result of their high efficiency and sharp energy threshold, current BCs are almost ready for use in the development of a next-generation active assay system. Development of an instrument based on appropriately safe materials is warranted. (3) Both kinds of bubble detectors are ready for use whenever very high gamma-ray fields must be confronted. Spent fuel MPC and A is a good example where this need presents itself. (4) Both kinds of bubble detectors have the potential to function as low-cost replacements for conventional neutron detectors such as 3 He tubes. For SDDs

  11. Physics and engineering of radiation detection

    CERN Document Server

    Ahmed, Syed Naeem

    2007-01-01

    Physics and Engineering of Radiation Detection presents an overview of basic physics of radiation and its applications and covers the origins and properties of different kinds of ionizing radiation, their detection and measurement, and the procedures used to protect people and the environment from their potentially harmful effects. Covering both the basic physics of radiation and its applications, it will provide an up-to-date and coherent account of the origins and properties of the different kinds of ionizing radiation, and their detection and measurement. This book will illustrate the basic physical principles with an abundance of practical, worked-out examples, numerical problems, real world applications, and data, including biological effects, radon, risk assessment, and statistics.

  12. Activities on calibration of radiation protection instruments in Indonesia

    International Nuclear Information System (INIS)

    Trijoko, S.

    1995-01-01

    As the use of the ionizing radiation emitted by radionuclides or produced by modern machines in Indonesia has increased significantly in the past two decades, the demand for radiation protection measures has also grown up very rapidly. In the mind of Indonesian people, ionizing radiation is always associated with atomic bombs. Indonesian government has set up National Atomic Energy Agency (BATAN) through the Act No. 31/1964. The BATAN has responsibility in the research and development, implementation and inspection of the safe use of ionizing radiation for peaceful purposes, and always put a great concern on radiation protection matter. The Center for Standardization and Radiation Safety Research (CSRSR) has been founded to implement research and services in the fields of radiation safety, standardization, dosimetry, radiation health, as well as the application of nuclear techniques to medicine. In order to provide the national reference in terms of radiation dosimetry and calibration, the Secondary Standard Dosimetry Laboratory was completely set up in Jakarta by 1984. As available facilities, radiation instruments and radiation sources are described. Calibration and personal monitoring services are reported. (K.I.)

  13. Radiation protection commissioning of neutron beam instruments at the OPAL research reactor

    International Nuclear Information System (INIS)

    Parkes, Alison; Saratsopoulos, John; Deura, Michael; Kenny, Pat

    2008-01-01

    The neutron beam facilities at the 20 MW OPAL Research Reactor were commissioned in 2007 and 2008. The initial suite of eight neutron beam instruments on two thermal neutron guides, two cold neutron guides and one thermal beam port located at the reactor face, together with their associated shielding were progressively installed and commissioned according to their individual project plans. Radiation surveys were systematically conducted as reactor power was raised in a step-wise manner to 20 MW in order to validate instrument shielding design and performance. The performance of each neutron guide was assessed by neutron energy spectrum and flux measurements. The activation of beam line components, decay times assessments and access procedures for Bragg Institute beam instrument scientists were established. The multiple configurations for each instrument and the influence of operating more than one instrument or beamline simultaneously were also tested. Areas of interest were the shielding around the secondary shutters, guide shield and bunker shield interfaces and monochromator doors. The shielding performance, safety interlock checks, improvements, radiation exposures and related radiation protection challenges are discussed. This paper discusses the health physics experience of commissioning the OPAL Research Reactor neutron beam facilities and describes health physics results, actions taken and lessons learned during commissioning. (author)

  14. INSTRUMENTATION FOR ENVIRONMENTAL MONITORING--Radiation--Vol3Pt1

    Energy Technology Data Exchange (ETDEWEB)

    Authors, Various

    1972-01-02

    A comprehensive survey of instrumentation for environmental monitoring is being carried out by the Lawrence Berkeley Laboratory originally under a grant from the National Science Foundation and now by the Office of Health and Environmental Research of the Department of Energy. Instruments being investigated are those useful for measurements in Air Quality, Water Quality, Radiation, and Biomedicine related to environmental research and monitoring. Consideration is given to instruments and techniques presently in use and to those developed for other purposes but having possible applications to this work. The results of the survey are given as (a) descriptions of the physical and operating characteristics of available instruments, (b) critical comparisons among instrumentation methods, and (c) recommendations of promising methodology and development of new instrumentation. Information is also given regarding the pollutants to be monitored: their characteristics and forms, their sources and pathways, their effects on the ecosystem, and the means of controlling them through process and regulatory controls.

  15. Minimum detectable activities of contamination control survey equipment

    International Nuclear Information System (INIS)

    Goles, R.W.; Baumann, B.L.; Johnson, M.L.

    1991-08-01

    The Instrumentation ampersand External Dosimetry (I ampersand ED) Section of the Health Physics Department at the Pacific Northwest Laboratory (PNL) has performed a series of tests to determine the ability of portable survey instruments used at Hanford to detect radioactive contamination at levels required by DOE 5480.11. This semi-empirical study combines instrumental, statistical, and human factors as necessary to derive operational detection limits. These threshold detection values have been compared to existing contamination control requirements, and detection deficiencies have been identified when present. Portable survey instruments used on the Hanford Site identify the presence of radioactive surface contamination based on the detection of α-, β-, γ-, and/or x-radiation. However, except in some unique circumstances, most contamination monitors in use at Hanford are configured to detect either α-radiation alone or β- and γ-radiation together. Testing was therefore conducted on only these two categories of radiation detection devices. Nevertheless, many of the results obtained are generally applicable to all survey instruments, allowing performance evaluations to be extended to monitoring devices which are exclusively γ- and/or x-ray- sensitive. 6 figs., 2 tabs

  16. Polyphonic pitch detection and instrument separation

    Science.gov (United States)

    Bay, Mert; Beauchamp, James W.

    2005-09-01

    An algorithm for polyphonic pitch detection and musical instrument separation is presented. Each instrument is represented as a time-varying harmonic series. Spectral information is obtained from a monaural input signal using a spectral peak tracking method. Fundamental frequencies (F0s) for each time frame are estimated from the spectral data using an Expectation Maximization (EM) algorithm with a Gaussian mixture model representing the harmonic series. The method first estimates the most predominant F0, suppresses its series in the input, and then the EM algorithm is run iteratively to estimate each next F0. Collisions between instrument harmonics, which frequently occur, are predicted from the estimated F0s, and the resulting corrupted harmonics are ignored. The amplitudes of these corrupted harmonics are replaced by harmonics taken from a library of spectral envelopes for different instruments, where the spectrum which most closely matches the important characteristics of each extracted spectrum is chosen. Finally, each voice is separately resynthesized by additive synthesis. This algorithm is demonstrated for a trio piece that consists of 3 different instruments.

  17. Physics and engineering of radiation detection

    CERN Document Server

    Ahmed, Syed Naeem

    2015-01-01

    Physics and Engineering of Radiation Detection presents an overview of the physics of radiation detection and its applications. It covers the origins and properties of different kinds of ionizing radiation, their detection and measurement, and the procedures used to protect people and the environment from their potentially harmful effects. The second edition is fully revised and provides the latest developments in detector technology and analyses software. Also, more material related to measurements in particle physics and a complete solutions manual have been added.

  18. Atmospheric Radiation Measurement Climate Research Facility (ACRF Instrumentation Status: New, Current, and Future)

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2008-01-30

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development.

  19. Computer aided in-flight radiation scanning

    International Nuclear Information System (INIS)

    Schmitzer, C.; Kloesch, W.

    1989-01-01

    The equipment consists of a radiation detecting instrument, a flight prospection probe and a portable PC. It is aimed at detection of ground radiation sources from a flying airplane, e.g. in case of radiation accident. 3 figs

  20. Nuclear radiation monitoring instruments for personnel in nuclear disaster for defence needs

    International Nuclear Information System (INIS)

    Bhatnagar, P.K.; Vaijapurkar, S.G.; Yadav, Ashok

    2005-01-01

    Ever since the tragedy of nuclear device exploding over Japan by USA in 1945 awareness exists amongst the armed forces personnel all over the world that a requirement of implementing radiological protection is imminent. Towards this adoption of radiological safety programme is a criterion. In a nuclear war disaster scenario, one encounters initial nuclear radiation (gamma and neutron radiations), gamma radiations from fallout, heat and blast. At certain distances Tanks/ armoured vehicles will survive and 4 R/s radiation level sensing to actuate relays for closing the ports of vehicles is essential, leading to reduction in inhalation, ingestion of fallout radioactivity and reduction in radiation dose received by occupants of the vehicle. Towards this sturdy radiation monitors to indicate gamma dose rate of the order of 1000 R/h, gamma and neutron dosimeters of the order of 1000 cGy with reading instruments are to be developed. These must work in harsh environment and sustain JSS 55555 conditions of army. Defence Laboratory, Jodhpur over past one decade has been involved in developing personnel, area and field monitoring instruments like dosimeters, survey meters, which are useful, acceptable to army personnel, armoured and personnel carrier vehicles, field structures/shelters. Technology transfer after satisfaction of armed forces, product ionisation and supply, maintenance, training has been the endeavor of the DRDO. Herein it is proposed to highlight the techno electronics nuclear radiation monitoring sensors and associated electronics systems developed first time in the country and productionised in bulk for Services for implementing personnel protection. The sensors developed and described are - Radiophotoluminescent Glass (RPLG) for gamma radiation dosimetry , neutron sensitive PIN diode for fast neutron dosimetry, gamma radiation sensitive PIN diode, superheated liquid neutron and gamma sensors. The dosimeter, dose rate meter and field/area instruments are

  1. New analytical portable instrument for microchip electrophoresis with electrochemical detection.

    Science.gov (United States)

    Fernández-la-Villa, Ana; Pozo-Ayuso, Diego F; Castaño-Alvarez, Mario

    2010-08-01

    A new portable instrument that includes a high voltage power supply, a bipotentiostat, and a chip holder has been especially developed for using microchips electrophoresis with electrochemical detection. The main unit of the instrument has dimensions of 150 x 165 x 70 mm (wxdxh) and consists of a four-outputs high voltage power supply with a maximum voltage of +/-3 KV and an acquisition system with two channels for dual amperometric (DC or pulsed amperometric detection) detection. Electrochemical detection has been selected as signal transduction method because it is relatively easily implemented, since nonoptical elements are required. The system uses a lithium-ion polymer battery and it is controlled from a desktop or laptop PC with a graphical user interface based on LabVIEW connected by serial RS232 or Bluetooth. The last part of the system consists of a reusable chip holder for housing the microchips, which contain all the electrical connections and reservoirs for making the work with microchips easy. The performance of the new instrument has been evaluated and compared with other commercially available apparatus using single- and dual-channel pyrex microchips for the separation of the neurotransmitters dopamine, epinephrine, and 3,4-dihydroxy-L-phenyl-alanine. The reduction of the size of the instrument has not affected the good performance of the separation and detection using microchips electrophoresis with electrochemical detection. Moreover, the new portable instrument paves the way for in situ analysis making the use of microchips electrophoresis easier.

  2. Computer-based instrumentation for partial discharge detection in GIS

    International Nuclear Information System (INIS)

    Md Enamul Haque; Ahmad Darus; Yaacob, M.M.; Halil Hussain; Feroz Ahmed

    2000-01-01

    Partial discharge is one of the prominent indicators of defects and insulation degradation in a Gas Insulated Switchgear (GIS). Partial discharges (PD) have a harmful effect on the life of insulation of high voltage equipment. The PD detection using acoustic technique and subsequent analysis is currently an efficient method of performing non-destructive testing of GIS apparatus. A low cost PC-based acoustic PD detection instrument has been developed for the non-destructive diagnosis of GIS. This paper describes the development of a PC-based instrumentation system for partial discharge detection in GIS and some experimental results have also presented. (Author)

  3. Counterbalanced radiation detection device

    International Nuclear Information System (INIS)

    Platz, W.

    1986-01-01

    A counterbalanced radiation detection device is described which consists of: (a) a base; (b) a radiation detector having a known weight; (c) means connected with the radiation detector and the base for positioning the radiation detector in different heights with respect to the base; (d) electronic component means movably mounted on the base for counterbalancing the weight of the radiation detector; (e) means connected with the electronic component means and the radiation detector positioning means for positioning the electronic component means in different heights with respect to the base opposite to the heights of the radiation detector; (f) means connected with the radiation detector and the base for shifting the radiation detector horizontally with respect to the base; and (g) means connected with the electronic component means and the radiation detector shifting means for shifting the electronic component means horizontally with respect to the base in opposite direction to shifting of the radiation detector

  4. DOE Fundamentals Handbook: Instrumentation and Control, Volume 1

    International Nuclear Information System (INIS)

    1992-06-01

    The Instrumentation and Control Fundamentals Handbook was developed to assist nuclear facility operating contractors provide operators, maintenance personnel, and the technical staff with the necessary fundamentals training to ensure a basic understanding of instrumentation and control systems. The handbook includes information on temperature, pressure, flow, and level detection systems; position indication systems; process control systems; and radiation detection principles. This information will provide personnel with an understanding of the basic operation of various types of DOE nuclear facility instrumentation and control systems

  5. DOE Fundamentals Handbook: Instrumentation and Control, Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    1992-06-01

    The Instrumentation and Control Fundamentals Handbook was developed to assist nuclear facility operating contractors provide operators, maintenance personnel, and the technical staff with the necessary fundamentals training to ensure a basic understanding of instrumentation and control systems. The handbook includes information on temperature, pressure, flow, and level detection systems; position indication systems; process control systems; and radiation detection principles. This information will provide personnel with an understanding of the basic operation of various types of DOE nuclear facility instrumentation and control systems.

  6. DOE Fundamentals Handbook: Instrumentation and Control, Volume 2

    International Nuclear Information System (INIS)

    1992-06-01

    The Instrumentation and Control Fundamentals Handbook personnel, and the technical staff facility operating contractors provide operators, maintenance personnel, and the technical staff with the necessary fundamentals training to ensure a basic understanding of instrumentation and control systems. The handbook includes information on temperature, pressure, flow, and level detection systems; position indication systems; process control systems; and radiation detection principles. This information will provide personnel with an understanding of the basic operation of various types of DOE nuclear facility instrumentation and control systems

  7. Radiation detection and measurement concepts, methods and devices

    CERN Document Server

    McGregor, Douglas

    2019-01-01

    This text on radiation detection and measurement is a response to numerous requests expressed by students at various universities, in which the most popularly used books do not provide adequate background material, nor explain matters in understandable terms. This work provides a modern overview of radiation detection devices and radiation measurement methods. The topics selected in the book have been selected on the basis of the author’s many years of experience designing radiation detectors and teaching radiation detection and measurement in a classroom environment.

  8. Remote Optical Detection of Alpha Radiation

    International Nuclear Information System (INIS)

    Sand, J.; Hannuksela, V.; Toivonen, J.; Ihantola, S.; Peraejaervi, K.; Toivonen, H.

    2010-01-01

    Alpha emitting radiation sources are typically hard to detect with conventional detectors due to the short range of alpha particles in the air. However, previous studies have shown that remote detection of alpha radiation is possible by measuring the ionization-induced fluorescence of air molecules. The alpha-induced ultraviolet (UV) light is mainly emitted by molecular nitrogen and its fluorescence properties are well known. The benefit of this method is the long range of UV photons in the air. Secondly, the detection is possible also under a strong beta and gamma radiation backgrounds as they do not cause localized molecular excitation. In this work, the optical detection was studied using two different detection schemes; spectral separation of fluorescence from the background lighting and coincidence detection of UV photons originating from a single radiative decay event. Our spectrally integrated measurements have shown that one alpha decay event yields up to 400 fluorescence photons in the air and all these UV photons are induced in a 5 ns time-window. On the other hand, the probability of a background coincidence event in 5 ns scale is very rare compared to the number of background photons. This information can be applied in fluorescence coincidence filtering to discriminate the alpha radiation initiated fluorescence signal from much more intense background lighting. A device called HAUVA (Handheld Alpha UV Application) was built during this work for demonstration purposes. HAUVA utilizes spectral filtering and it is designed to detect alpha emitters from a distance of about 40 cm. Using specially selected room lighting, the device is able to separate 1 kBq alpha emitter from the background lighting with 1 second integration time. (author)

  9. Three Canted Radiator Panels to Provide Adequate Cooling for Instruments on Slewing Spacecraft in LEO

    Science.gov (United States)

    Choi, Michael K.

    2012-01-01

    Certain free-flying spacecraft in low Earth orbit (LEO) or payloads on the International Space Station (ISS) are required to slew to point the telescopes at targets. Instrument detectors and electronics require cooling. Traditionally a planar thermal radiator is used. The temperature of such a radiator varies significantly when the spacecraft slews because its view factors to space vary significantly. Also for payloads on the ISS, solar impingement on the radiator is possible. These thermal adversities could lead to inadequate cooling for the instrument. This paper presents a novel thermal design concept that utilizes three canted radiator panels to mitigate this problem. It increases the overall radiator view factor to cold space and reduces the overall solar or albedo flux absorbed per unit area of the radiator.

  10. Trends in instrumentation for environmental radiation measurements at Los Alamos Scientific Laboratory

    International Nuclear Information System (INIS)

    Hiebert, R.D.; Wolf, M.A.

    1980-01-01

    Recent instruments developed to fulfill radiation monitoring needs at Los Alamos Scientific Laboratory are described. Laboratory instruments that measure tritium gas effluents alone, or in the presence of activated air from D-T fusion reactors are discussed. Fully portable systems for gamma, x-ray, and alpha analyses in the field are described. Also included are descriptions of survey instruments that measure low levels of transuranic contaminants and that measure pulsed-neutron dose rates

  11. Technical testing of portable isotope identification instruments

    International Nuclear Information System (INIS)

    Smith, D.E.

    2001-01-01

    Full text: The United States Customs Service has, as a part of its mission, the protection of the borders of the United States from the import or export of illicit radioactive materials. Of paramount importance is the ability to interdict the smuggling of special nuclear material, nuclear weapons and other radioactive materials that could be used as a weapon of mass destruction against the population and infrastructure of the U.S. or another country. Radiation detection technology exists in the form of pocket size, hand-held and portal radiation detectors that have the ability to detect radiation with great sensitivity and low false alarm rates. U.S. Customs has chosen to implement pocket size detectors or radiation pagers as the personal tool of each inspector for the detection of radioactive material. In the search for illicit shipment of radioactive materials, innocent radiation detections may occur with some frequency due to common radioactive sources that may be encountered in day to day living. Examples include lantern mantles, some camera lenses, welding rods, certain dishware containing uranium glaze, and natural marble objects such as statues or architectural pieces. Perhaps the most common innocent detection encountered at the border and in public areas in general is due to the in vivo placement of radioactive sources for use in nuclear medicine therapy and diagnostics. Outpatients from such therapy can remain detectable for three weeks or more. Also, legal shipments of radioisotopes are common occurrences in cargo and express mail shipments. The customs inspector who detects radioactive material in the course of his duties must decide whether detection is innocent; is indicative of a nuclear device or special nuclear material; or whether the source could be injurious to him/her or the general public. It is at this point that a portable instrument capable of identifying gamma or neutron emitting isotopes is essential to the customs examination procedure

  12. Optical fiber-applied radiation detection system

    International Nuclear Information System (INIS)

    Nishiura, Ryuichi; Uranaka, Yasuo; Izumi, Nobuyuki

    2001-01-01

    A technique to measure radiation by using plastic scintillation fibers doped radiation fluorescent (scintillator) to plastic optical fiber for a radiation sensor, was developed. The technique contains some superiority such as high flexibility due to using fibers, relatively easy large area due to detecting portion of whole of fibers, and no electromagnetic noise effect due to optical radiation detection and signal transmission. Measurable to wide range of and continuous radiation distribution along optical fiber cable at a testing portion using scintillation fiber and flight time method, the optical fiber-applied radiation sensing system can effectively monitor space radiation dose or apparatus operation condition monitoring. And, a portable type scintillation optical fiber body surface pollution monitor can measure pollution concentration of radioactive materials attached onto body surface by arranging scintillation fiber processed to a plate with small size and flexibility around a man to be tested. Here were described on outline and fundamental properties of various application products using these plastic scintillation fiber. (G.K.)

  13. Radioisotope instruments

    CERN Document Server

    Cameron, J F; Silverleaf, D J

    1971-01-01

    International Series of Monographs in Nuclear Energy, Volume 107: Radioisotope Instruments, Part 1 focuses on the design and applications of instruments based on the radiation released by radioactive substances. The book first offers information on the physical basis of radioisotope instruments; technical and economic advantages of radioisotope instruments; and radiation hazard. The manuscript then discusses commercial radioisotope instruments, including radiation sources and detectors, computing and control units, and measuring heads. The text describes the applications of radioisotop

  14. Measurement and detection of radiation

    CERN Document Server

    Tsoulfanidis, Nicholas

    2015-01-01

    This fourth edition reflects recent major developments that have occurred in radiation detector materials, systems, and applications. It continues to provide the most practical and up-to-date introduction to radiation detector technology, proper measurement techniques, and analysis of results for engineers and scientists using radiation sources. New chapters emphasize the expanded use of radiation detection systems in nuclear non-proliferation, homeland security, and nuclear medicine. The book also discusses the correct ways to perform measurements following current health physics procedures.

  15. New technique for radiation detection by instruments based on microchannel plates

    International Nuclear Information System (INIS)

    Ammosov, V.V.; Bolozdynya, A.I.; Kubantsev, M.A.; Lebedenko, V.N.; Suvorov, A.L.

    1986-01-01

    Coordinate information can be obtained directly from microchanel plates (MCP) as storage matrix in MCP based radiation detectors, which is proved using as an example the registering of pulsed laser ultraviolet radiation. For read-out and representation of the information the TV channel was used: the vidicon electron-optical system - TV transmission camera - TV monitor

  16. Instrument evaluation no. 5. Wallac OY universal radiation survey meter type RD-8

    International Nuclear Information System (INIS)

    White, D.F.; Blundell, D.R.; Callowhill, K.; Iles, W.J.

    1976-05-01

    The Wallace RD-8 is a portable, battery-operated survey meter covering an exposure rate range from 0.01 mR/h to 300 R/h. The instrument was designed specifically for military and civil defence applications and is accordingly of particularly rugged construction and claimed to be both waterproof and shockproof. This instrument is unusual in that it has two internally mounted radiation detectors. An end-window GM tube is used to cover the range from 0.01 to 300 mR/h, and a GM tube covers the range from 0.01 to 300 R/h. Both tubes have energy compensation sheaths for the measurement of photon radiation in the forward direction. Only the first tube permits the measurement of β-radiation. The information is given under the following headings; Facilities and controls; radiation characteristics; electrical characteristics; environmental characteristics; mechanical characteristics; summary of performance; calibration procedure; conclusions. (U.K.)

  17. Resonance detection of Moessbauer radiation

    International Nuclear Information System (INIS)

    Morozov, V.V.

    1985-01-01

    The resonance detection method as compared with the usual method of registering Moessbauer spectra has a number of advantages, one of which is the increase of resolution of the Moessbauer spectrum. The method is based on the modulation of a secondary radiation of a converter tuned in the resonance with the Moessbauer gamma-quantum source. The resonance detection method with account of supression, secondary radiation outgoing from the converter is investigated. The converter represents a substrate enriched by the Moessbauer isotope placed either inside the gas counter, or coupled with any other detecting device. Analytical expressions for Moessbauer spectrum parameters: effect, area and width of the spectral line are derived. It is shown that the joint application of usual and resonance detection methods for registering the Moessbauer spectrum allows one to determine parameters of the source, converter and the investigated absorber

  18. Instrumentation for characterizing materials and composed semiconductors for ionizing radiation detectors

    International Nuclear Information System (INIS)

    Paschoal, Arquimedes J.A.; Leite, Adolfo M.B.; Nazzre, Fabio V.B.; Santos, Luiz A.P.

    2007-01-01

    The purpose of this work is the development of instrumentation for characterizing some type of ionizing radiation detectors. Those detectors are being manufactured by the Nuclear Instrumentation Laboratory at CRCN/Recife and can be used both on photon beam and with particles. Such detectors consist of semiconductor material in the form of films generated by oxide growing or by means of semiconductor material deposition in a substrate. Those materials can be made of metals, semi-metals, composites or semiconductor polymers. Prior to expose those detectors to ionizing radiation, it must be physically and electrically characterized. In this intention it was developed an electromechanical system. An electrical circuit was built to measure the signal from the detector and another circuit to control the movement of four probes (4-points technique) by using a stepper motor and the micro stepping technique avoiding damage to the detector. This system can be of interest to researchers that work with a sort of semiconductor materials in the form of thin film and in nanotechnological processes aiming the design of radiation ionizing detectors. (author)

  19. A MGy radiation-hardened sensor instrumentation link for nuclear reactor monitoring and remote handling

    Energy Technology Data Exchange (ETDEWEB)

    Verbeeck, Jens; Cao, Ying [KU Leuven - KUL, Div. LRD-MAGyICS, Kasteelpark Arenberg 10, 3001 Heverlee (Belgium); Van Uffelen, Marco; Mont Casellas, Laura; Damiani, Carlo; Morales, Emilio Ruiz; Santana, Roberto Ranz [Fusion for Energy - F4E, c/Josep,n deg. 2, Torres Diagonal Litoral, Ed. B3, 08019 Barcelona (Spain); Meek, Richard; Haist, Bernhard [Oxford Technologies Ltd. OTL, 7 Nuffield Way, Abingdon OX14 1RL (United Kingdom); De Cock, Wouter; Vermeeren, Ludo [SCK-CEN, Boeretang 200, 2400 Mol (Belgium); Steyaert, Michiel [KU Leuven, ESAT-MICAS, KasteelparkArenberg 10, 3001 Heverlee (Belgium); Leroux, Paul [KU Leuven, ESAT-MICAS, KasteelparkArenberg 10, 3001 Heverlee (Belgium)

    2015-07-01

    Decommissioning, dismantling and remote handling applications in nuclear facilities all require robotic solutions that are able to survive in radiation environments. Recently raised safety, radiation hardness and cost efficiency demands from both the nuclear regulatory and the society impose severe challenges in traditional methods. For example, in case of the dismantling of the Fukushima sites, solutions that survive accumulated doses higher than 1 MGy are mandatory. To allow remote operation of these tools in nuclear environments, electronics were used to be shielded with several centimeters of lead or even completely banned in these solutions. However, shielding electronics always leads to bulky and heavy solutions, which reduces the flexibility of robotic tools. It also requires longer repair time and produces extra waste further in a dismantling or decommissioning cycle. In addition, often in current reactor designs, due to size restrictions and the need to inspect very tight areas there are limitations to the use of shielding. A MGy radiation-hardened sensor instrumentation link developed by MAGyICS provides a solution to build a flexible, easy removable and small I and C module with MGy radiation tolerance without any shielding. Hereby it removes all these pains to implement electronics in robotic tools. The demonstrated solution in this poster is developed for ITER Remote Handling equipments operating in high radiation environments (>1 MGy) in and around the Tokamak. In order to obtain adequately accurate instrumentation and control information, as well as to ease the umbilical management, there is a need of front-end electronics that will have to be located close to those actuators and sensors on the remote handling tool. In particular, for diverter remote handling, it is estimated that these components will face gamma radiation up to 300 Gy/h (in-vessel) and a total dose of 1 MGy. The radiation-hardened sensor instrumentation link presented here, consists

  20. Development of multifunctional radiation monitoring instrument based on PLC technology

    International Nuclear Information System (INIS)

    Li Ziqiang; Zhu Yuye; Zhuang Min

    2007-01-01

    This eight-channel multifunctional Radiation Monitoring Instrument is developed by making use of the built-in high-speed counters and the powerful instruction system of the SIEMES SIMATICS S7 series Programmable Logic Controllers (PLC) to record and process the pulse signal output by the detectors. The instrument with functions, such as analog and digital display, digital storage of digital data, pulse signal generator, network communication, can connect various types of pulse detectors. The initial process can be translated between Graduation Apparatus method and Formula method. the logicality of the high-dosage warning system is processed itself. The signal output will drive the alarm lights and bell directly. This paper mainly describes the configuration, programming and feature of the instrument. (authors)

  1. Development of Quantum Devices and Algorithms for Radiation Detection and Radiation Signal Processing

    International Nuclear Information System (INIS)

    El Tokhy, M.E.S.M.E.S.

    2012-01-01

    The main functions of spectroscopy system are signal detection, filtering and amplification, pileup detection and recovery, dead time correction, amplitude analysis and energy spectrum analysis. Safeguards isotopic measurements require the best spectrometer systems with excellent resolution, stability, efficiency and throughput. However, the resolution and throughput, which depend mainly on the detector, amplifier and the analog-to-digital converter (ADC), can still be improved. These modules have been in continuous development and improvement. For this reason we are interested with both the development of quantum detectors and efficient algorithms of the digital processing measurement. Therefore, the main objective of this thesis is concentrated on both 1. Study quantum dot (QD) devices behaviors under gamma radiation 2. Development of efficient algorithms for handling problems of gamma-ray spectroscopy For gamma radiation detection, a detailed study of nanotechnology QD sources and infrared photodetectors (QDIP) for gamma radiation detection is introduced. There are two different types of quantum scintillator detectors, which dominate the area of ionizing radiation measurements. These detectors are QD scintillator detectors and QDIP scintillator detectors. By comparison with traditional systems, quantum systems have less mass, require less volume, and consume less power. These factors are increasing the need for efficient detector for gamma-ray applications such as gamma-ray spectroscopy. Consequently, the nanocomposite materials based on semiconductor quantum dots has potential for radiation detection via scintillation was demonstrated in the literature. Therefore, this thesis presents a theoretical analysis for the characteristics of QD sources and infrared photodetectors (QDIPs). A model of QD sources under incident gamma radiation detection is developed. A novel methodology is introduced to characterize the effect of gamma radiation on QD devices. The rate

  2. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2002-01-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described

  3. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2002-04-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described.

  4. Intercomparison of radiation protection instrumentation in a pulsed neutron field

    Energy Technology Data Exchange (ETDEWEB)

    Caresana, M., E-mail: marco.caresana@polimi.it [Politecnico di Milano, CESNEF, Dipartimento di Energia, via Ponzio 34/3, 20133 Milano (Italy); Denker, A. [Helmholtz-Zentrum Berlin für Materialien und Energie, Hahn-Meitner-Platz 1, D-14109 Berlin (Germany); Esposito, A. [IFNF-LNF, FISMEL, via E. Fermi 40, 00044 Frascati (Italy); Ferrarini, M. [CNAO, Via Privata Campeggi, 27100 Pavia (Italy); Golnik, N. [Institute of Metrology and Biomedical Engineering, Warsaw University of Technology, Sw. A. Boboli 8, 02-525 Warsaw (Poland); Hohmann, E. [Paul Scherrer Institut (PSI), Radiation Metrology Section, CH-5232 Villigen PSI (Switzerland); Leuschner, A. [Deutsches Elektronen-Synchrotron DESY, Notkestr. 85, 22603 Hamburg (Germany); Luszik-Bhadra, M. [Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig (Germany); Manessi, G. [CERN, 1211 Geneva 23 (Switzerland); University of Liverpool, Department of Physics, L69 7ZE Liverpool (United Kingdom); Mayer, S. [Paul Scherrer Institut (PSI), Radiation Metrology Section, CH-5232 Villigen PSI (Switzerland); Ott, K. [Helmholtz-Zentrum Berlin, BESSYII, Albert-Einstein-Str.15, 12489 Berlin (Germany); Röhrich, J. [Helmholtz-Zentrum Berlin für Materialien und Energie, Hahn-Meitner-Platz 1, D-14109 Berlin (Germany); Silari, M. [CERN, 1211 Geneva 23 (Switzerland); Trompier, F. [Institute for Radiological Protection and Nuclear Safety, F-92262 Fontenay aux Roses (France); Volnhals, M.; Wielunski, M. [Helmholtz Zentrum München, Ingolstädter Landstr. 1, D-85764 Neuherberg (Germany)

    2014-02-11

    In the framework of the EURADOS working group 11, an intercomparison of active neutron survey meters was performed in a pulsed neutron field (PNF). The aim of the exercise was to evaluate the performances of various neutron instruments, including commercially available rem-counters, personal dosemeters and instrument prototypes. The measurements took place at the cyclotron of the Helmholtz-Zentrum Berlin für Materialien und Energie GmbH. The cyclotron is routinely used for proton therapy of ocular tumours, but an experimental area is also available. For the therapy the machine accelerates protons to 68 MeV. The interaction of the proton beam with a thick tungsten target produces a neutron field with energy up to about 60 MeV. One interesting feature of the cyclotron is that the beam can be delivered in bursts, with the possibility to modify in a simple and flexible way the burst length and the ion current. Through this possibility one can obtain radiation bursts of variable duration and intensity. All instruments were placed in a reference position and irradiated with neutrons delivered in bursts of different intensity. The analysis of the instrument response as a function of the burst charge (the total electric charge of the protons in the burst shot onto the tungsten target) permitted to assess for each device the dose underestimation due to the time structure of the radiation field. The personal neutron dosemeters were exposed on a standard PMMA slab phantom and the response linearity was evaluated.

  5. Development of an instrument for fast monitoring of radiotherapy equipment

    International Nuclear Information System (INIS)

    Khoury, H.J.; Almeida Melo, F. de; Patriota, J.H.; Oliveira Lira, C.B. de

    1990-01-01

    Radiation therapy machines need a constant monitoring to assure tumoral dose accuracy. Special attention must be given to linear accelerators which should be checked frequently. By this reason, an instrument was developed at the Nuclear Instrumentation Laboratory DEN/UFPE to measure the output energy and beam symmetry. This instrument use three silicon photodiodes as radiation detectors. Two of then were localized at 5cm and 10cm depht at the central axis and one at 5 cm from the center, at the lateral irradiated field. Changes in the photon spectrum are detected by the ratio of upper to lower photodiode response. The radiation field uniformity is checked by the lateral photodiode. (author) [pt

  6. Bayesian Methods for Radiation Detection and Dosimetry

    CERN Document Server

    Groer, Peter G

    2002-01-01

    We performed work in three areas: radiation detection, external and internal radiation dosimetry. In radiation detection we developed Bayesian techniques to estimate the net activity of high and low activity radioactive samples. These techniques have the advantage that the remaining uncertainty about the net activity is described by probability densities. Graphs of the densities show the uncertainty in pictorial form. Figure 1 below demonstrates this point. We applied stochastic processes for a method to obtain Bayesian estimates of 222Rn-daughter products from observed counting rates. In external radiation dosimetry we studied and developed Bayesian methods to estimate radiation doses to an individual with radiation induced chromosome aberrations. We analyzed chromosome aberrations after exposure to gammas and neutrons and developed a method for dose-estimation after criticality accidents. The research in internal radiation dosimetry focused on parameter estimation for compartmental models from observed comp...

  7. Radiation monitoring and measuring instrument developed by Turkish Atomic Energy Authority

    International Nuclear Information System (INIS)

    Kuecuekarslan, N.; Gueven, A.

    2001-01-01

    Turkish Atomic Energy Authority (TAEA), Cekmece Nuclear Research and Training Center, Nuclear Electronics Department is working on research, development and production of radiation monitoring and measuring instruments in the aims of TAEA to serve our Country. Advanced micro controller technology is used to cover problems of radiation measurement. Control by micro controller enables reliable, stable measurement and display of low level dose rate fields. It makes possible the simultaneous measurement of both dose and dose rate values

  8. A leak-detection instrument for long buried pipelines based on radioactive tracer measurements

    International Nuclear Information System (INIS)

    Lu Qingqian; Zhou Shuxuan; Tang Yonghua; Sun Xiaolei; Hu Xusheng; Li Deyi; Yin Liqiang

    1987-01-01

    The instrument introduced provides a means for leak detection of long buried pipelines based on the radioactive tracer technique. The principle, block diagram and performances for the instrument are described. The leak-detecting method and the determination of some related parameters are also presented. Leak-detection sensitivity of the instrument is 185 kBq (5 μCi). Accuracy for leak localization is within 2.5 m (per km). It is suitable for the buried light oil (gasoline, kerosene, diesel oil) and industrial water pipelines with a diameter of 15 or 20 cm. The detection length for a single operation reaches up to 50 km

  9. Building 772 - CERN’s new calibration facility for radiation protection instruments is ready to go

    CERN Document Server

    2014-01-01

    Building 772 is becoming the new home of CERN’s calibration facility for radiation protection instrumentation. The new laboratory in Prévessin will be a state-of-the-art calibration facility and the first of its kind in both France and Switzerland, offering a wide range of possibilities with respect to radiation fields and instrumentation.   New four-axis calibration bench for radiation protection instruments.   Civil engineering work started in November 2013 in Prévessin and Building 772 is now finished and ready for inauguration. CERN’s calibration facility was previously located in Building 172 in Meyrin. Although still very accurate, the technology used was becoming obsolete and needed replacement. “Having considered different options, the decision was taken to build a new facility fully designed and conceived to meet all international safety and technical requirements of such a laboratory,” says Pie...

  10. Overview of the atmospheric ionizing radiation environment monitoring by Bulgarian build instruments

    Science.gov (United States)

    Dachev, Tsvetan; Tomov, Borislav; Matviichuk, Yury; Dimitrov, Plamen; Spurny, Frantisek; Ploc, Ondrej; Uchihori, Yukio; Flueckiger, Erwin; Kudela, Karel; Benton, Eric

    2012-10-01

    Humans are exposed to ionizing radiation all the time, and it is known that it can induce a variety of harmful biological effects. Consequently, it is necessary to quantitatively assess the level of exposure to this radiation as the basis for estimating risks for their health. Spacecraft and aircraft crews are exposed to elevated levels of cosmic radiation of galactic and solar origin and to secondary radiation produced in the atmosphere, the vehicle structure and its contents. The aircraft crew monitoring is required by the following recommendations of the International Commission on Radiological Protection (ICRP) (ICRP 1990), the European Union (EU) introduced a revised Basic Safety Standards Directive (EC 1997) which, inter alia, included the exposure to cosmic radiation. This approach has been also adopted in other official documents (NCRP 2002). In this overview we present the results of ground based, mountain peaks, aircraft, balloon and rocket radiation environment monitoring by means of a Si-diode energy deposition spectrometer Liulin type developed first in Bulgarian Academy of Sciences (BAS) for the purposes of the space radiation monitoring at MIR and International Space Station (ISS). These spectrometers-dosemeters are further developed, calibrated and used by scientific groups in different countries. Calibration procedures of them are performed at different accelerators including runs in the CERN high-energy reference field, simulating the radiation field at 10 km altitude in the atmosphere and with heavy ions in Chiba, Japan HIMAC accelerator were performed also. The long term aircraft data base were accumulated using specially developed battery operated instrument in 2001-2009 years onboard of A310-300 aircrafts of Czech Air Lines, during 24 about 2 months runs with more than 2000 flights and 13500 flight hours on routes over the Atlantic Ocean mainly. The obtained experimental data are compared with computational models like CARI and EPCARD. The

  11. Analog electronics for radiation detection

    CERN Document Server

    2016-01-01

    Analog Electronics for Radiation Detection showcases the latest advances in readout electronics for particle, or radiation, detectors. Featuring chapters written by international experts in their respective fields, this authoritative text: Defines the main design parameters of front-end circuitry developed in microelectronics technologies Explains the basis for the use of complementary metal oxide semiconductor (CMOS) image sensors for the detection of charged particles and other non-consumer applications Delivers an in-depth review of analog-to-digital converters (ADCs), evaluating the pros and cons of ADCs integrated at the pixel, column, and per-chip levels Describes incremental sigma delta ADCs, time-to-digital converter (TDC) architectures, and digital pulse-processing techniques complementary to analog processing Examines the fundamental parameters and front-end types associated with silicon photomultipliers used for single visible-light photon detection Discusses pixel sensors ...

  12. Measuring element for the detection and determination of radiation doses of gamma radiation and neutrons

    International Nuclear Information System (INIS)

    Jahn, W.; Piesch, E.

    1975-01-01

    A measuring element detects and proves both gamma and neutron radiation. The element includes a photoluminescent material which stores gamma radiation and particles of arsenic and phosphorus embedded in the photoluminescent material for detecting neutron radiation. (U.S.)

  13. Radiation detection system

    International Nuclear Information System (INIS)

    Haeuszer, F.A.

    1976-01-01

    A circuit is disclosed that detects radiation transients and provides a clamping signal in response to each transient. The clamping signal is present from the time the transient rises above a given threshold level and for a known duration thereafter. The system includes radiation sensors, a blocking oscillator that generates a pulse in response to each sensor signal, and an output pulse duration control circuit. The oscillator pulses are fed simultaneously to the output pulse duration control circuit and to an OR gate, the output of which comprises the system output. The output pulse duration is controlled by the time required to magnetize a magnetic core to saturation in first one direction and then the other

  14. Measurement and detection of radiation

    National Research Council Canada - National Science Library

    Tsoulfanidis, Nicholas; Landsberger, Sheldon

    2011-01-01

    .... With the miniaturization of equipment, increased speed of electronic components, and more sophisticated software, radiation detection systems are now more productively used in many disciplines...

  15. Portable instrument for selectively detecting alpha-particles derived from radon

    International Nuclear Information System (INIS)

    Chapuis, A.M.; DaJlevic, D.

    1975-01-01

    A portable instrument of the pocket type designed primarily for monitoring atmospheric contamination in uranium mines by selectively detecting the α-particles emitted simultaneously by the daughter products of radon, namely radium A and radium C' is described. The instrument comprises in combination a tube containing a suction fan for drawing external air through a filter which retains the α-emitting aerosols, a detector in which the α-particles corresponding to the respective energies of the α-emissions of radium A and of radium C' are detected separately, and two collimators placed between the filter and the detector

  16. Instruments for radiation measurement in biosciences. Series 3. radioluminography. 1. Results of questionnaires to the scientists using radioluminographic techniques

    International Nuclear Information System (INIS)

    Kurihara, Norio; Nakajima, Eiichi; Takahashi, Sentaro

    1998-01-01

    Radioluminography (RLG) is a method to detect radioactivity with its photostimulated luminescence phenomenon. This paper describes major results of questionnaires to the scientists using RLG technique which was performed by the technical subcommittee for research instruments for isotope tracer of Life Science Section, Japan Radioisotope Association. The main purpose was to find the advantage and problems of RLG recognized by users. Questionnaires were sent to 271 users and 101 answers were obtained from pharmaceutical companies, universities and other public research facilities. RLG was found mainly used in gel electrophoresis in the molecular biology field, thin layer chromatography and quantitative whole body autoradiography. RLG technology itself of the instrument, imaging plate and standard usage was found to be in progress as well. Problems were those on the fundamental handling (e.g., ROI definition), on instruments, on quantitativeness, on different nuclides, on value for formal data and on radiation control. The major instrument manufacturers were Fuji Film Co., BioRad Co. and Molecular Dynamics Co. Results of the questionnaire will be published in more detailed form in future. (K.H.)

  17. The design of nuclear radiation measuring instrument of embedded network

    International Nuclear Information System (INIS)

    Zhang Huaiqiang; Ge Liangquan; Xiong Shengqing

    2009-01-01

    The design and realization of nuclear radiation measuring instrument is introduced. Due to the current nuclear instrument often used serial interface to communicate the PC, it is widely used for simple design and easy operation. However, as the demand of remote data acquisition and the call of sharing resources, the design of embedded the TCP/IP protocol stack into MCU, it may send the nuclear signal in Internet. Some devices that link each other with the network can be networked. The design is not only realizing remote data acquisition and sharing resources, but also reducing costs and improving the maintainability of the system. (authors)

  18. Three-dimensional, position-sensitive radiation detection

    Science.gov (United States)

    He, Zhong; Zhang, Feng

    2010-04-06

    Disclosed herein is a method of determining a characteristic of radiation detected by a radiation detector via a multiple-pixel event having a plurality of radiation interactions. The method includes determining a cathode-to-anode signal ratio for a selected interaction of the plurality of radiation interactions based on electron drift time data for the selected interaction, and determining the radiation characteristic for the multiple-pixel event based on both the cathode-to-anode signal ratio and the electron drift time data. In some embodiments, the method further includes determining a correction factor for the radiation characteristic based on an interaction depth of the plurality of radiation interactions, a lateral distance between the selected interaction and a further interaction of the plurality of radiation interactions, and the lateral positioning of the plurality of radiation interactions.

  19. Radiation Detection Computational Benchmark Scenarios

    Energy Technology Data Exchange (ETDEWEB)

    Shaver, Mark W.; Casella, Andrew M.; Wittman, Richard S.; McDonald, Ben S.

    2013-09-24

    Modeling forms an important component of radiation detection development, allowing for testing of new detector designs, evaluation of existing equipment against a wide variety of potential threat sources, and assessing operation performance of radiation detection systems. This can, however, result in large and complex scenarios which are time consuming to model. A variety of approaches to radiation transport modeling exist with complementary strengths and weaknesses for different problems. This variety of approaches, and the development of promising new tools (such as ORNL’s ADVANTG) which combine benefits of multiple approaches, illustrates the need for a means of evaluating or comparing different techniques for radiation detection problems. This report presents a set of 9 benchmark problems for comparing different types of radiation transport calculations, identifying appropriate tools for classes of problems, and testing and guiding the development of new methods. The benchmarks were drawn primarily from existing or previous calculations with a preference for scenarios which include experimental data, or otherwise have results with a high level of confidence, are non-sensitive, and represent problem sets of interest to NA-22. From a technical perspective, the benchmarks were chosen to span a range of difficulty and to include gamma transport, neutron transport, or both and represent different important physical processes and a range of sensitivity to angular or energy fidelity. Following benchmark identification, existing information about geometry, measurements, and previous calculations were assembled. Monte Carlo results (MCNP decks) were reviewed or created and re-run in order to attain accurate computational times and to verify agreement with experimental data, when present. Benchmark information was then conveyed to ORNL in order to guide testing and development of hybrid calculations. The results of those ADVANTG calculations were then sent to PNNL for

  20. Diagnostic instrumentation for detection of the onset of steam tube leaks in PWRs

    International Nuclear Information System (INIS)

    Roach, W.H.

    1984-01-01

    Four tasks are addressed in this study of the detection of steam tube leaks: determination of which physical parameters indicate the onset of steam generator tube leaks; establishing performance goals for diagnostic instruments which could be used for early detection of steam generator tube leaks; defining the diagnostic instrumentation and their location which satisfy Items 1 and 2; and assessing the need for diagnostic data processing and display. Parameters are identified, performance goals established and sensor types and locations are specified in the report, with emphasis on the use of existing instrumentation with a minimum of retrofitting. A simple algorithm is developed which yields the leak rate as a function of known or measurable quantities. The conclusion is that leak rates of less than one-tenth gram per second should be detectable with existing instrumentation

  1. Proceedings of symposium on intelligent nuclear instrumentation-2001

    International Nuclear Information System (INIS)

    Kataria, S.K.; Vaidya, P.P.; Das, Debashis; Narurkar, P.V.

    2001-02-01

    Advances in the field of instrumentation are relevant to many areas of importance such as nuclear and accelerator based research, reactor monitoring and control, non-destructive testing and evaluation, laser programme and health and environment monitoring etc. The nuclear instrumentation is a specialized field with very specific expertise in detection, processing and its analysis. The symposium covers various fields of nuclear interest such as radiation detectors, application of ASICs and FPGA in instruments, field instruments, nuclear instrumentation for basic research, accelerator, reactor, health and environmental monitoring instrumentation, medical instrumentation, instrument net working inclusive of field buses, WEB based and wireless technologies, software tools, AI technique in instrumentation etc., in this specialized area. Papers relevant to INIS are indexed separately

  2. Highly sensitive rapid fluorescence detection of protein residues on surgical instruments

    International Nuclear Information System (INIS)

    Kovalev, Valeri I; Bartona, James S; Richardson, Patricia R; Jones, Anita C

    2006-01-01

    There is a risk of contamination of surgical instruments by infectious protein residues, in particular, prions which are the agents for Creutzfeldt-Jakob Disease in humans. They are exceptionally resistant to conventional sterilization, therefore it is important to detect their presence as contaminants so that alternative cleaning procedures can be applied. We describe the development of an optimized detection system for fluorescently labelled protein, suitable for in-hospital use. We show that under optimum conditions the technique can detect ∼10 attomole/cm 2 with a scan speed of ∼3-10 cm 2 /s of the test instrument's surface. A theoretical analysis and experimental measurements will be discussed

  3. Detection of random alterations to time-varying musical instrument spectra.

    Science.gov (United States)

    Horner, Andrew; Beauchamp, James; So, Richard

    2004-09-01

    The time-varying spectra of eight musical instrument sounds were randomly altered by a time-invariant process to determine how detection of spectral alteration varies with degree of alteration, instrument, musical experience, and spectral variation. Sounds were resynthesized with centroids equalized to the original sounds, with frequencies harmonically flattened, and with average spectral error levels of 8%, 16%, 24%, 32%, and 48%. Listeners were asked to discriminate the randomly altered sounds from reference sounds resynthesized from the original data. For all eight instruments, discrimination was very good for the 32% and 48% error levels, moderate for the 16% and 24% error levels, and poor for the 8% error levels. When the error levels were 16%, 24%, and 32%, the scores of musically experienced listeners were found to be significantly better than the scores of listeners with no musical experience. Also, in this same error level range, discrimination was significantly affected by the instrument tested. For error levels of 16% and 24%, discrimination scores were significantly, but negatively correlated with measures of spectral incoherence and normalized centroid deviation on unaltered instrument spectra, suggesting that the presence of dynamic spectral variations tends to increase the difficulty of detecting spectral alterations. Correlation between discrimination and a measure of spectral irregularity was comparatively low.

  4. The All Terrain Bio nano Gear for Space Radiation Detection System

    International Nuclear Information System (INIS)

    Ummat, Ajay; Mavroidis, Constantinos

    2007-01-01

    This paper discusses about the relevance of detecting space radiations which are very harmful and pose numerous health issues for astronauts. There are many ways to detect radiations, but we present a non-invasive way of detecting them in real-time while an astronaut is in the mission. All Terrain Bio-nano (ATB) gear system is one such concept where we propose to detect various levels of space radiations depending on their intensity and warn the astronaut of probable biological damage. A basic framework for radiation detection system which utilizes bio-nano machines is discussed. This radiation detection system is termed as 'radiation-responsive molecular assembly' (RMA) for the detection of space radiations. Our objective is to create a device which could detect space radiations by creating an environment equivalent to human cells within its structure and bio-chemically sensing the effects induced therein. For creating such an environment and further bio-chemically sensing space radiations bio-nano systems could be potentially used. These bio-nano systems could interact with radiations and signal based on the intensity of the radiations their relative biological effectiveness. Based on the energy and kind of radiation encountered, a matrix of signals has to be created which corresponds to a particular biological effect. The key advantage of such a design is its ability to interact with the radiation at e molecular scale; characterize its intensity based on energy deposition and relate it to the relative biological effectiveness based on the correspondence established through molecular structures and bond strengths of the bio-nano system

  5. Computer-based nuclear radiation detection and instrumentation teaching laboratory system

    International Nuclear Information System (INIS)

    Ellis, W.H.; He, Q.

    1993-01-01

    The integration of computers into the University of Florida's Nuclear Engineering Sciences teaching laboratories is based on the innovative use of MacIntosh 2 microcomputers, IEEE-488 (GPIB) communication and control bus system and protocol, compatible modular nuclear instrumentation (NIM) and test equipment, LabVIEW graphics and applications software, with locally prepared, interactive, menu-driven, HyperCard based multi-exercise laboratory instruction sets and procedures. Results thus far have been highly successful with the majority of the laboratory exercises having been implemented

  6. Adaptive search and detection of laser radiation

    International Nuclear Information System (INIS)

    Efendiev, F.A.; Kasimova, F.I.

    2008-01-01

    Formation of cosmic optical line connected with the solving of difficult problems, among which stand out spatial search task, detection and target tracking. Indeed, the main advantage of systems of the optical diapason, high radiation direction leads to a challenging task of entering in communication, consisting in mutual targeting antenna receiving and transmitting systems. Algorithm detection, obtained by solving the corresponding statistical optimal detection test synthesis tasks detector determines the structure and quality of his work which depend on the average characteristics of the signal and the background radiation of the thermal noise require full priori certainty about the conditions of observation. Algorithm of the optimal detector of laser light modulated on a sub carrier frequency of intensity assumes a priori known intensity and efficiency background radiation and internal noise power photo detector

  7. Establishment of 137Cs radiation fields for instrument calibration

    International Nuclear Information System (INIS)

    Albuquerque, M. da P.P.; Caldas, L.V.E.; Xavier, M.

    1988-09-01

    In order to study the energy dependence of clinical dosemeters, systems constituted of ionization chambers connected to special electrometers, many times their calibration with the gamma radiation of 137 Cs is necessary. In this case, the radiation field characterization is fundamental. The source used presents and activity of 38,8 Tbq and belongs to the Calibration Laboratory of IPEN. Dosimetric films, gammagraphy films, ionization chambers and Lucite phantons were used. At the calibration distance, 80 cm (detector-source detection), the homogeneity of a 10 X 10 cm 2 radiation field was equal 68%. (author) [pt

  8. Labor security in radiation flaw detection

    International Nuclear Information System (INIS)

    Margulis, U.Ya.; Chistov, E.D.; Partolin, O.F.; Pertsov, V.A.; Momzhiev, B.N.; Sprygaev, I.F.

    1986-01-01

    Problems of ensuring safe labour conditions in radiation flaw detection are considered. Methods for ionizing radiation protection are given calculating techniques for shielding flaw detectors and stationary structures are presented as well. Safe methods of nondestructive testing of items under field conditions, in a shop and special laboratories using gamma- and X-ray flaw detectors, betatrons, electron accelerators are described. Attention is paid to the principles of radiation factor stantardization as well as radiation monitoring. Analysis of accidents and recommendations on their prevention and liquidation of accidental consequences are given

  9. Performance of the HIRS/2 instrument on TIROS-N. [High Resolution Infrared Radiation Sounder

    Science.gov (United States)

    Koenig, E. W.

    1980-01-01

    The High Resolution Infrared Radiation Sounder (HIRS/2) was developed and flown on the TIROS-N satellite as one means of obtaining atmospheric vertical profile information. The HIRS/2 receives visible and infrared spectrum radiation through a single telescope and selects 20 narrow radiation channels by means of a rotating filter wheel. A passive radiant cooler provides an operating temperature of 106.7 K for the HgCdTe and InSb detectors while the visible detector operates at instrument frame temperature. Low noise amplifiers and digital processing provide 13 bit data for spacecraft data multiplexing and transmission. The qualities of system performance that determine sounding capability are the dynamic range of data collection, the noise equivalent radiance of the system, the registration of the air columns sampled in each channel and the ability to upgrade the calibration of the instrument to maintain the performance standard throughout life. The basic features, operating characteristics and performance of the instrument in test are described. Early orbital information from the TIROS-N launched on October 13, 1978 is given and some observations on system quality are made.

  10. Workplace monitoring for radiation and contamination

    International Nuclear Information System (INIS)

    2004-01-01

    Ionizing radiations cannot be seen, felt or sensed by the human body in any way but excessive exposure to them may have adverse health effects. Radiation measuring instruments are needed in order to detect the presence of such radiations and avoid excessive exposure. The use of appropriate and efficient instruments enables exposures to be controlled and the doses received to be kept as low as reasonably achievable. This Manual explains the basic terminology associated with such measuring instruments and describes the principal types, their construction and typical applications in the workplace. It is important to ensure not only that monitoring is carried out where there is a potential radiation exposure but also that the monitoring instrument is appropriate to the task and that the user places correct interpretations on the results obtained. The Manual will be of most benefit if it forms part of more comprehensive training or is supplemented by the advice of a qualified expert in radiation protection. Some of the instrument tests and calibrations described in this Manual require the services of a qualified expert

  11. Detection of Radiation-Exposure Biomarkers by Differential Mobility Prefiltered Mass Spectrometry (DMS-MS).

    Science.gov (United States)

    Coy, Stephen L; Krylov, Evgeny V; Schneider, Bradley B; Covey, Thomas R; Brenner, David J; Tyburski, John B; Patterson, Andrew D; Krausz, Kris W; Fornace, Albert J; Nazarov, Erkinjon G

    2010-04-15

    Technology to enable rapid screening for radiation exposure has been identified as an important need, and, as a part of a NIH / NIAD effort in this direction, metabolomic biomarkers for radiation exposure have been identified in a recent series of papers. To reduce the time necessary to detect and measure these biomarkers, differential mobility spectrometry - mass spectrometry (DMS-MS) systems have been developed and tested. Differential mobility ion filters preselect specific ions and also suppress chemical noise created in typical atmospheric-pressure ionization sources (ESI, MALDI, and others). Differential-mobility-based ion selection is based on the field dependence of ion mobility, which, in turn, depends on ion characteristics that include conformation, charge distribution, molecular polarizability, and other properties, and on the transport gas composition which can be modified to enhance resolution. DMS-MS is able to resolve small-molecule biomarkers from nearly-isobaric interferences, and suppresses chemical noise generated in the ion source and in the mass spectrometer, improving selectivity and quantitative accuracy. Our planar DMS design is rapid, operating in a few milliseconds, and analyzes ions before fragmentation. Depending on MS inlet conditions, DMS-selected ions can be dissociated in the MS inlet expansion, before mass analysis, providing a capability similar to MS/MS with simpler instrumentation. This report presents selected DMS-MS experimental results, including resolution of complex test mixtures of isobaric compounds, separation of charge states, separation of isobaric biomarkers (citrate and isocitrate), and separation of nearly-isobaric biomarker anions in direct analysis of a bio-fluid sample from the radiation-treated group of a mouse-model study. These uses of DMS combined with moderate resolution MS instrumentation indicate the feasibility of field-deployable instrumentation for biomarker evaluation.

  12. Highly sensitive rapid fluorescence detection of protein residues on surgical instruments

    Energy Technology Data Exchange (ETDEWEB)

    Kovalev, Valeri I [School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh EH14 4AS (United Kingdom); Bartona, James S [School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh EH14 4AS (United Kingdom); Richardson, Patricia R [School of Chemistry, University of Edinburgh, Edinburgh, EH9 3JJ (United Kingdom); Jones, Anita C [School of Chemistry, University of Edinburgh, Edinburgh, EH9 3JJ (United Kingdom)

    2006-07-15

    There is a risk of contamination of surgical instruments by infectious protein residues, in particular, prions which are the agents for Creutzfeldt-Jakob Disease in humans. They are exceptionally resistant to conventional sterilization, therefore it is important to detect their presence as contaminants so that alternative cleaning procedures can be applied. We describe the development of an optimized detection system for fluorescently labelled protein, suitable for in-hospital use. We show that under optimum conditions the technique can detect {approx}10 attomole/cm{sup 2} with a scan speed of {approx}3-10 cm{sup 2}/s of the test instrument's surface. A theoretical analysis and experimental measurements will be discussed.

  13. An instrument for real time detection of contamination in space environmental tests chambers

    Science.gov (United States)

    Richmond, R. G.; Harmon, H. N.

    1972-01-01

    An instrument for in situ vacuum detection of surface reflectance changes at 1216A was designed. Using successive reflections, this instrument is more sensitive as an indicator of reflectance changes than similar instruments having only a single reflection. The selection of each component of the instrument and its operational performance is discussed.

  14. Pulse X-radiation in flaw detection

    International Nuclear Information System (INIS)

    Vavilov, S.P.; Gorbunov, V.I.

    1985-01-01

    Principles of physical and engineering application of pulse X-radiation (PXR) of micro- and nanosecond duration for nondestructive testing of processes, materials and devices are given. Methods and devices, aimed at generating X-ray pulses, as well as their radiation and flow detection characteristics, and testing methods by means of PXR are considered

  15. New small devices for radiation detection: the Wee Pocket Chirper and the Portable Multichannel Analyzer

    International Nuclear Information System (INIS)

    Umbarger, C.J.

    1980-08-01

    Recent events have demonstrated the need for improved capability to monitor the exposure of workers to radiation and, in general, to identify and measure the many forms of radioactive materials found throughout the nuclear industry. Two radiation monitoring devices have been developed that are much smaller than existing instruments, yet exhibit superior performance and a longer battery life. The first instrument, the Wee Pocket Chirper, is a tiny, battery-powered warning device that chirps when exposed to radiation. The second instrument is a portable battery-powered, computer-based, multichannel analyzer that allows the user to examine radiation fields and to identify the types and amounts of radioactive materials present

  16. FJ-2207 measuring instrument detection pipe surface a level of pollution method

    International Nuclear Information System (INIS)

    Wang Jiangong

    2010-01-01

    On the pipe surface contamination were detected α level of pollution is a frequently encountered dose-detection work. Because the pipeline surface arc, while the measuring probe for the plane, which for accurate measurement difficult. In this paper, on the FJ-2207-type pipe surface contamination measuring instrument measuring pollution levels in the α method was studied. Introduced the FJ-2207 measuring instrument detection pipe surface α pollution levels. Studied this measuring instrument on the same sources of surface, plane α level of radioactivity measured differences in the results obtained control of the apparatus when the direct measurement of the surface correction factor, and gives 32-216 specifications commonly used pipe direct measurement of the amendment factor. Convenient method, test results are reliable for the accurate measurement of pipe pollution levels in the surface of α as a reference and learning. (authors)

  17. Bayesian Methods for Radiation Detection and Dosimetry

    International Nuclear Information System (INIS)

    Peter G. Groer

    2002-01-01

    We performed work in three areas: radiation detection, external and internal radiation dosimetry. In radiation detection we developed Bayesian techniques to estimate the net activity of high and low activity radioactive samples. These techniques have the advantage that the remaining uncertainty about the net activity is described by probability densities. Graphs of the densities show the uncertainty in pictorial form. Figure 1 below demonstrates this point. We applied stochastic processes for a method to obtain Bayesian estimates of 222Rn-daughter products from observed counting rates. In external radiation dosimetry we studied and developed Bayesian methods to estimate radiation doses to an individual with radiation induced chromosome aberrations. We analyzed chromosome aberrations after exposure to gammas and neutrons and developed a method for dose-estimation after criticality accidents. The research in internal radiation dosimetry focused on parameter estimation for compartmental models from observed compartmental activities. From the estimated probability densities of the model parameters we were able to derive the densities for compartmental activities for a two compartment catenary model at different times. We also calculated the average activities and their standard deviation for a simple two compartment model

  18. Detection by EPR method of radiation treatment in dried fruits containing crystalline sugar

    International Nuclear Information System (INIS)

    Lehner, K.; Stachowicz, W.

    2006-01-01

    The results of EPR (electron paramagnetic resonance) measurements are presented on the detection ability and stability of radiation induced sugar-born radicals in the samples of dried (dehydrated) fruits available in the market and related to doses of 0.5, 1 and 3 kGy, respectively. The experiments have been conducted during 12 months of storage. Measurements were done with an EPR - 10 MINI spectrometer in X band (frequency of microwaves 9.5 GHz), St. Petersburg Instruments Ltd. The aim of the work was to prove the reliability of acceptability of the method in routine control of irradiated food. (author)

  19. Intercomparison of NO3 radical detection instruments in the atmosphere simulation chamber SAPHIR

    Directory of Open Access Journals (Sweden)

    H.-P. Dorn

    2013-05-01

    Full Text Available The detection of atmospheric NO3 radicals is still challenging owing to its low mixing ratios (≈ 1 to 300 pptv in the troposphere. While long-path differential optical absorption spectroscopy (DOAS has been a well-established NO3 detection approach for over 25 yr, newly sensitive techniques have been developed in the past decade. This publication outlines the results of the first comprehensive intercomparison of seven instruments developed for the spectroscopic detection of tropospheric NO3. Four instruments were based on cavity ring-down spectroscopy (CRDS, two utilised open-path cavity-enhanced absorption spectroscopy (CEAS, and one applied "classical" long-path DOAS. The intercomparison campaign "NO3Comp" was held at the atmosphere simulation chamber SAPHIR in Jülich (Germany in June 2007. Twelve experiments were performed in the well-mixed chamber for variable concentrations of NO3, N2O5, NO2, hydrocarbons, and water vapour, in the absence and in the presence of inorganic or organic aerosol. The overall precision of the cavity instruments varied between 0.5 and 5 pptv for integration times of 1 s to 5 min; that of the DOAS instrument was 9 pptv for an acquisition time of 1 min. The NO3 data of all instruments correlated excellently with the NOAA-CRDS instrument, which was selected as the common reference because of its superb sensitivity, high time resolution, and most comprehensive data coverage. The median of the coefficient of determination (r2 over all experiments of the campaign (60 correlations is r2 = 0.981 (quartile 1 (Q1: 0.949; quartile 3 (Q3: 0.994; min/max: 0.540/0.999. The linear regression analysis of the campaign data set yielded very small intercepts (median: 1.1 pptv; Q1/Q3: −1.1/2.6 pptv; min/max: −14.1/28.0 pptv, and the slopes of the regression lines were close to unity (median: 1.01; Q1/Q3: 0.92/1.10; min/max: 0.72/1.36. The deviation of individual regression slopes from unity was always within the combined

  20. A real-time radiation mapping system

    International Nuclear Information System (INIS)

    Scoggins, W.A.; VanEtten, D.M.

    1988-01-01

    A prototype of a real-time radiation mapping system, Ranger, was developed to respond to an accident involving the release of plutonium for the Department of Energy's Accident Response Group. In 1987 Ranger demonstrated that it can provide an efficient method of monitoring large areas of land for radioactive contamination. With the experience gained from the operation of the prototype, the external computer and software are being upgraded in order to obtain a fully operational system. The new system uses the prototype's commercially available line-of-sight microwave system for determining position and the same radiation detection instruments. The data obtained from the radiation detection instrument(s) are linked back to the external computer along with the relative position of the measurement through the ranging system. The data are displayed on a gridded map as colored circles and permanently stored in real-time. The different colors represent different contamination levels. Contours can be drawn using the permanently stored data. 4 figs

  1. Basics of radiation physics and instrumentation

    International Nuclear Information System (INIS)

    Royal, H.D.

    1985-01-01

    Continued technical developments are greatly changing medical diagnosis and medical care. In the field of cardiology, a number of new imaging techniques are currently available. This chapter reviews several topics that are important in the practice of nuclear cardiology. The first section discusses some of the basics of nuclear physics. Familiarity with these fundamentals is essential for an in-depth understanding of nuclear cardiology. The second section presents information on radiotracers and provides dosimetry estimates for commonly performed studies. The third section reviews the instruments used to detect radioactivity. The final section discusses computers and their applications and limitations in nuclear cardiology

  2. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2001-04-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor.

  3. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2001-01-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor

  4. Simulating and Detecting Radiation-Induced Errors for Onboard Machine Learning

    Science.gov (United States)

    Wagstaff, Kiri L.; Bornstein, Benjamin; Granat, Robert; Tang, Benyang; Turmon, Michael

    2009-01-01

    Spacecraft processors and memory are subjected to high radiation doses and therefore employ radiation-hardened components. However, these components are orders of magnitude more expensive than typical desktop components, and they lag years behind in terms of speed and size. We have integrated algorithm-based fault tolerance (ABFT) methods into onboard data analysis algorithms to detect radiation-induced errors, which ultimately may permit the use of spacecraft memory that need not be fully hardened, reducing cost and increasing capability at the same time. We have also developed a lightweight software radiation simulator, BITFLIPS, that permits evaluation of error detection strategies in a controlled fashion, including the specification of the radiation rate and selective exposure of individual data structures. Using BITFLIPS, we evaluated our error detection methods when using a support vector machine to analyze data collected by the Mars Odyssey spacecraft. We found ABFT error detection for matrix multiplication is very successful, while error detection for Gaussian kernel computation still has room for improvement.

  5. Multi-sensor radiation detection, imaging, and fusion

    Energy Technology Data Exchange (ETDEWEB)

    Vetter, Kai [Department of Nuclear Engineering, University of California, Berkeley, CA 94720 (United States); Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States)

    2016-01-01

    Glenn Knoll was one of the leaders in the field of radiation detection and measurements and shaped this field through his outstanding scientific and technical contributions, as a teacher, his personality, and his textbook. His Radiation Detection and Measurement book guided me in my studies and is now the textbook in my classes in the Department of Nuclear Engineering at UC Berkeley. In the spirit of Glenn, I will provide an overview of our activities at the Berkeley Applied Nuclear Physics program reflecting some of the breadth of radiation detection technologies and their applications ranging from fundamental studies in physics to biomedical imaging and to nuclear security. I will conclude with a discussion of our Berkeley Radwatch and Resilient Communities activities as a result of the events at the Dai-ichi nuclear power plant in Fukushima, Japan more than 4 years ago. - Highlights: • .Electron-tracking based gamma-ray momentum reconstruction. • .3D volumetric and 3D scene fusion gamma-ray imaging. • .Nuclear Street View integrates and associates nuclear radiation features with specific objects in the environment. • Institute for Resilient Communities combines science, education, and communities to minimize impact of disastrous events.

  6. Networked gamma radiation detection system for tactical deployment

    Science.gov (United States)

    Mukhopadhyay, Sanjoy; Maurer, Richard; Wolff, Ronald; Smith, Ethan; Guss, Paul; Mitchell, Stephen

    2015-08-01

    A networked gamma radiation detection system with directional sensitivity and energy spectral data acquisition capability is being developed by the National Security Technologies, LLC, Remote Sensing Laboratory to support the close and intense tactical engagement of law enforcement who carry out counterterrorism missions. In the proposed design, three clusters of 2″ × 4″ × 16″ sodium iodide crystals (4 each) with digiBASE-E (for list mode data collection) would be placed on the passenger side of a minivan. To enhance localization and facilitate rapid identification of isotopes, advanced smart real-time localization and radioisotope identification algorithms like WAVRAD (wavelet-assisted variance reduction for anomaly detection) and NSCRAD (nuisance-rejection spectral comparison ratio anomaly detection) will be incorporated. We will test a collection of algorithms and analysis that centers on the problem of radiation detection with a distributed sensor network. We will study the basic characteristics of a radiation sensor network and focus on the trade-offs between false positive alarm rates, true positive alarm rates, and time to detect multiple radiation sources in a large area. Empirical and simulation analyses of critical system parameters, such as number of sensors, sensor placement, and sensor response functions, will be examined. This networked system will provide an integrated radiation detection architecture and framework with (i) a large nationally recognized search database equivalent that would help generate a common operational picture in a major radiological crisis; (ii) a robust reach back connectivity for search data to be evaluated by home teams; and, finally, (iii) a possibility of integrating search data from multi-agency responders.

  7. On the radiative and thermodynamic properties of the cosmic radiations using COBE FIRAS instrument data: I. Cosmic microwave background radiation

    Science.gov (United States)

    Fisenko, Anatoliy I.; Lemberg, Vladimir

    2014-07-01

    Using the explicit form of the functions to describe the monopole and dipole spectra of the Cosmic Microwave Background (CMB) radiation, the exact expressions for the temperature dependences of the radiative and thermodynamic functions, such as the total radiation power per unit area, total energy density, number density of photons, Helmholtz free energy density, entropy density, heat capacity at constant volume, and pressure in the finite range of frequencies v 1≤ v≤ v 2 are obtained. Since the dependence of temperature upon the redshift z is known, the obtained expressions can be simply presented in z representation. Utilizing experimental data for the monopole and dipole spectra measured by the COBE FIRAS instrument in the 60-600 GHz frequency interval at the temperature T=2.72548 K, the values of the radiative and thermodynamic functions, as well as the radiation density constant a and the Stefan-Boltzmann constant σ are calculated. In the case of the dipole spectrum, the constants a and σ, and the radiative and thermodynamic properties of the CMB radiation are obtained using the mean amplitude T amp=3.358 mK. It is shown that the Doppler shift leads to a renormalization of the radiation density constant a, the Stefan-Boltzmann constant σ, and the corresponding constants for the thermodynamic functions. The expressions for new astrophysical parameters, such as the entropy density/Boltzmann constant, and number density of CMB photons are obtained. The radiative and thermodynamic properties of the Cosmic Microwave Background radiation for the monopole and dipole spectra at redshift z≈1089 are calculated.

  8. Ionizing radiations, detection, dosimetry, spectrometry

    International Nuclear Information System (INIS)

    Blanc, D.

    1997-10-01

    A few works in French language are devoted to the detection of radiations. The purpose of this book is to fill a gap.The five first chapters are devoted to the properties of ionizing radiations (x rays, gamma rays, leptons, hadrons, nuclei) and to their interactions with matter. The way of classification of detectors is delicate and is studied in the chapter six. In the chapter seven are studied the statistics laws for counting and the spectrometry of particles is treated. The chapters eight to thirteen study the problems of ionization: charges transport in a gas, ionization chambers (theory of Boag), counters and proportional chambers, counters with 'streamers', chambers with derive, spark detectors, ionization chambers in liquid medium, Geiger-Mueller counters. The use of a luminous signal is the object of the chapters 14 to 16: conversion of a luminous signal in an electric signal, scintillators, use of the Cerenkov radiation. Then, we find the neutron detection with the chapter seventeen and the dosimetry of particles in the chapter eighteen. This book does not pretend to answer to specialists questions but can be useful to physicians, engineers or physics teachers. (N.C.)

  9. Study on Instrument Fault Detection using OLM Techniques for PHM Application in NPPs

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Hwan; Park, Gee Yong; Kim, Jung Taek; Hur, Seop [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    The diagnosis system is relatively being mature owing to many research. Among the various models, this paper introduces some On-Line Monitoring (OLM) models for instrument health monitoring and review applicability on NPPs. In recent years, many researchers are being focused on the prognostics which is predicting the future failure of instruments or equipment by using the status monitoring data. By using the prognostic techniques, we can expect a lot of advantages such as ease of control, power optimization, or optimal use of maintenance resources. And we have performed the test for detecting fault of safety-critical instruments and analyzed the fault detection sensitivity for various instrument failure modes using OLM techniques. OLM techniques using data-driven based model such AAKR or AANN can be useful tools for securing integrity of safety-critical instrument that should always keep healthy conditions for the plant safety.

  10. The design of a simple radon-detecting instrument based on MCU

    International Nuclear Information System (INIS)

    Du Genyuan; Qiu Yingyu; Zhang Jiang

    2007-01-01

    Introduction are given on the internal composition of the radon-detecting instrument based on MCU and the working of the real electric circuit. The single-chip microcomputer P89C58 of PHILIPS is adopted as the micro-controller of the instrument, realizing such functions as counting input pulses within fixed time, data processing, liquid crystal display, keyboard interface, serial communication, etc. The instrument turns out to be low in work consumption, with relatively high degree of concentration and computerization, and is recommended for field operations. (authors)

  11. The design of a simple radon-detecting instrument based on MCU

    International Nuclear Information System (INIS)

    Du Genyuan; Chen Jianjun; Zhang Jiang

    2008-01-01

    Introduction are given on the internal composition of the radon-detecting instrument based on MCU and the working of the real electric circuit. The single-chip microcomputer P89C58 of PHILIPS is adopted as the micro-controller of the instrument, realizing such functions as counting input pulses within fixed time, data processing, liquid crystal display, keyboard interface, serial communication, etc. The instrument turns out to be low in work consumption, with relatively high degree of concentration and computerization, and is recommended for field operations. (authors)

  12. Raman Life Detection Instrument Development for Icy Worlds

    Science.gov (United States)

    Thomson, Seamus; Allen, A'Lester; Gutierrez, Daniel; Quinn, Richard C.; Chen, Bin; Koehne, Jessica E.

    2017-01-01

    The objective of this project is to develop a compact, high sensitivity Raman sensor for detection of life signatures in a flow cell configuration to enable bio-exploration and life detection during future mission to our Solar Systems Icy Worlds. The specific project objectives are the following: 1) Develop a Raman spectroscopy liquid analysis sensor for biosignatures; 2) Demonstrate applicability towards a future Enceladus or other Icy Worlds missions; 3) Establish key parameters for integration with the ARC Sample Processor for Life on Icy Worlds (SPLIce); 4) Position ARC for a successful response to upcoming Enceladus or other Icy World mission instrument opportunities.

  13. Assembly of gamma radiation detection with directivity properties

    International Nuclear Information System (INIS)

    Stoica, M.; Talpalariu, C.

    2016-01-01

    An assembly of gamma radiation detection with directivity properties and small size enables the development of portable equipment or robots specialized in finding and signaling radioactively contaminated areas in case of nuclear incidents or decommissioning of nuclear installations. Directivity characteristic of the assembly of gamma radiation detection is very important when aiming to build an equipment for searching radioactively contaminated areas. In order to obtain a suitable directivity characteristics in terms of detection of gamma rays, it was necessary to construct a lead collimator with a cylindrical shape. The detector, preamplifier and amplifier pulse were placed inside the collimator and pulse discriminator circuit and power source were placed beside the collimator, all being disposed within the housing cylindrical experimental. A PIN photodiode type was used as a detector of gamma radiation. (authors)

  14. Real-time instrument-failure detection in the LOFT pressurizer using functional redundancy

    International Nuclear Information System (INIS)

    Tylee, J.L.

    1982-07-01

    The functional redundancy approach to detecting instrument failures in a pressurized water reactor (PWR) pressurizer is described and evaluated. This real-time method uses a bank of Kalman filters (one for each instrument) to generate optimal estimates of the pressurizer state. By performing consistency checks between the output of each filter, failed instruments can be identified. Simulation results and actual pressurizer data are used to demonstrate the capabilities of the technique

  15. New portable hand-held radiation instruments for measurements and monitoring

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1987-01-01

    Hand-held radiation monitors are often used to search pedestrians and motor vehicles for special nuclear material (SNM) as part of a physical protection plan for nuclear materials. Recently, the Los Alamos Advanced Nuclear Technology group has commercialized an improved hand-held monitor that can be used for both physical-protection monitoring and verification measurements in nuclear material control and waste management. The new monitoring instruments are smaller and lighter; operate much longer on a battery charge; are available with NaI(Tl) or neutron and gamma-ray sensitive plastic scintillation detectors; and are less expensive than other comparable instruments. They also have a second operating mode for making precise measurements over counting times as long as 99 s. This mode permits making basic verification measurements that may be needed before transporting nuclear material or waste outside protected areas. Improved verification measurements can be made with a second new hand-held instrument that has a stabilized detector and three separate gamma-ray energy windows to obtain spectral information for SNM quantity, enrichment, or material-type verification

  16. Detection of nuclear radiations; Deteccion de Radiaciones nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Tanarro Sanz, A

    1967-07-01

    A summary of the lectures about the ordinary detectors of nuclear radiations explained by the author in the courses of Nuclear Engineering held at the J.E.N. up to the date of publication is given. Those lectures are considered to be a necessary introduction to Nuclear Instrumentation and Applied Electronics to Nuclear Engineering so it has been intended to underline those characteristics of radiation detectors that must be taken in consideration in choosing or designing the electronic equipment associated to them in order to take advantage of each detector possibilities. (Author)

  17. Detection of nuclear radiations; Detectores de radiaciones nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Tanarro Sanz, A

    1959-07-01

    A summary of the lectures about the ordinary detectors of nuclear radiations given by the author in the Courses of Introduction to Nuclear Engineering held at the JEN up to the date of publication is given. Those lectures are considered to be a necessary introduction to Nuclear Instrumentation and Applied electronics to Nuclear Engineering so it has been intent to underline those characteristics of radiation detectors that must be taken in consideration in choosing or designing the electronic equipment associated to them in order to take advantage of each detector possibilities. (Author) 8 refs.

  18. Development of smart nuclear instrumentation for reactors

    International Nuclear Information System (INIS)

    Chaganty, S.P.; Das, D.; Bhatnagar, P.V.; Das, A.; Sreedharan, Preetha; Kataria, S.K.

    2001-01-01

    Variety of nuclear instruments are required for different applications in reactors such as reactor start-up, reactor protection and regulating system, area monitoring, failed fuel detection, stack monitoring etc. Attempts are made to develop a standardized microcomputer based hardware for configuring different types of instruments. PC architecture is chosen due to easy availability of components/boards and software. These instruments have dual redundant Network Interface Cards for connecting to a Primary Radiation Data LAN which in turn can be connected to Plant Information Bus through Gateways. These SMART instruments can be tested/calibrated through specific commands from remote computers connected over the LAN. This paper describes the various issues involved and the design details. (author)

  19. Reactor instrumentation and control

    International Nuclear Information System (INIS)

    Wach, D.; Beraha, D.

    1980-01-01

    The methods for measuring radiation are shortly reviewed. The instrumentation for neutron flux measurement is classified into out-of-core and in-core instrumentation. The out-of-core instrumentation monitors the operational range from the subcritical reactor to full power. This large range is covered by several measurement channels which derive their signals from counter tubes and ionization chambers. The in-core instrumentation provides more detailed information on the power distribution in the core. The self-powered neutron detectors and the aeroball system in PWR reactors are discussed. Temperature and pressure measurement devices are briefly discussed. The different methods for leak detection are described. In concluding the plant instrumentation part some new monitoring systems and analysis methods are presented: early failure detection methods by noise analysis, acoustic monitoring and vibration monitoring. The presentation of the control starts from an qualitative assessment of the reactor dynamics. The chosen control strategy leads to the definition of the part-load diagram, which provides the set-points for the different control systems. The tasks and the functions of these control systems are described. In additiion to the control, a number of limiting systems is employed to keep the reactor in a safe operating region. Finally, an outlook is given on future developments in control, concerning mainly the increased application of process computers. (orig./RW)

  20. Analysis of the Failures and Corrective Actions for the LHC Cryogenics Radiation Tolerant Electronics and its Field Instruments

    CERN Document Server

    Balle, Ch; Vauthier, N

    2014-01-01

    The LHC cryogenic system radiation tolerant electronics and their associated field instruments have been in nominal conditions since before the commissioning of the first LHC beams in September 2008. This system is made of about 15’000 field instruments (thermometers, pressure sensors, liquid helium level gauges, electrical heaters and position switches), 7’500 electronic cards and 853 electronic crates. Since mid-2008 a software tool has been deployed, this allows an operator to report a problem and then lists the corrective actions. The tool is a great help in detecting recurrent problems that may be tackled by a hardware or software consolidation. The corrective actions range from simple resets, exchange of defective equipment, repair of electrical connectors, etc. However a recurrent problem that heals by itself is present on some channels. This type of fault is extremely difficult to diagnose and it appears as a temporary opening of an electrical circuit; its duration can range from a few minutes to ...

  1. Survey and analysis of radiation safety management systems at medical institutions. Second report. Radiation measurement, calibration of radiation survey meters, and periodic check of installations, equipment, and protection instruments

    International Nuclear Information System (INIS)

    Ohba, Hisateru; Ogasawara, Katsuhiko; Aburano, Tamio

    2006-01-01

    We carried out a questionnaire survey to determine the actual situation of radiation safety management measures in all medical institutions in Japan that had nuclear medicine facilities. The questionnaire consisted of questions concerning the evaluation of shielding capacity; radiation measurement; periodic checks of installations, equipment, and protection instruments; and the calibration of radiation survey meters. The analysis was undertaken according to region, type of establishment, and number of beds. The overall response rate was 60 percent. For the evaluation of shielding capacity, the outsourcing rate was 53 percent of the total. For the radiation measurements of ''leakage radiation dose and radioactive contamination'' and contamination of radioactive substances in the air'', the outsourcing rates were 28 percent and 35 percent of the total, respectively (p<0.001, according to region and establishment). For the periodic check of radiation protection instruments, the implementation rate was 98 percent, and the outsourcing rate was 32 percent for radiation survey meters and 47 percent for lead aprons. The non-implemented rate for calibration of radiation survey meters was 25 percent of the total (p<0.001, according to region and establishment). The outsourcing rate for calibration of radiation survey meters accounted for 87 percent of the total, and of these medical institutions, 72 percent undertook annual calibration. The implementation rate for patient exposure measurement was 20 percent of the total (p<0.001, according to number of beds), and of these medical institutions 46 percent recorded measurement outcome. (author)

  2. Graphene Field Effect Transistor for Radiation Detection

    Science.gov (United States)

    Li, Mary J. (Inventor); Chen, Zhihong (Inventor)

    2016-01-01

    The present invention relates to a graphene field effect transistor-based radiation sensor for use in a variety of radiation detection applications, including manned spaceflight missions. The sensing mechanism of the radiation sensor is based on the high sensitivity of graphene in the local change of electric field that can result from the interaction of ionizing radiation with a gated undoped silicon absorber serving as the supporting substrate in the graphene field effect transistor. The radiation sensor has low power and high sensitivity, a flexible structure, and a wide temperature range, and can be used in a variety of applications, particularly in space missions for human exploration.

  3. Design and operation of dust measuring instrumentation based on the beta-radiation method

    International Nuclear Information System (INIS)

    Lilienfeld, P.

    1975-01-01

    The theory, instrument design aspects and applications of beta-radiation attenuation for the measurement of the mass concentration of airborne particulates are reviewed. Applicable methods of particle collection, beta sensing configurations, source ( 63 Ni, 14 C, 147 Pr, 85 Kr) and detector design criteria, electronic signal processing, digital control and instrument programming techniques are treated. Advantages, limitations and error sources of beta-attenuation instrumentation are analyzed. Applications to industrial dust measurements, source testing, ambient monitoring, and particle size analysis are the major areas of practical utilization of this technique, and its inherent capability for automated and unattended operation provides compatibility with process control synchronization and alarm, telemetry, and incorporation into pollution monitoring network sensing stations. (orig.) [de

  4. Conception of the Instrument Calibration Laboratory of Ionizing Radiation Measurement (LACIMRI) of CTMSP - Sao Paulo, SP

    International Nuclear Information System (INIS)

    Silva, Raimundo Dias da; Kibrit, Eduardo

    2009-01-01

    The present work describes the phases of implantation of calibration laboratory of ionizing radiation measurement instruments at the CTMSP, Sao Paulo, in a priory approved by CNEN, Brazil. That laboratory will allow and enhance the present metrological capacity for the attendance to the growing demand for calibration services of the instruments

  5. The radiation budget of stratocumulus clouds measured by tethered balloon instrumentation: Variability of flux measurements

    Science.gov (United States)

    Duda, David P.; Stephens, Graeme L.; Cox, Stephen K.

    1990-01-01

    Measurements of longwave and shortwave radiation were made using an instrument package on the NASA tethered balloon during the FIRE Marine Stratocumulus experiment. Radiation data from two pairs of pyranometers were used to obtain vertical profiles of the near-infrared and total solar fluxes through the boundary layer, while a pair of pyrgeometers supplied measurements of the longwave fluxes in the cloud layer. The radiation observations were analyzed to determine heating rates and to measure the radiative energy budget inside the stratocumulus clouds during several tethered balloon flights. The radiation fields in the cloud layer were also simulated by a two-stream radiative transfer model, which used cloud optical properties derived from microphysical measurements and Mie scattering theory.

  6. Plan for the testing of radiation measurement instrumentation intended for use at an excavation site

    International Nuclear Information System (INIS)

    Gehrke, R.J.

    1994-11-01

    This plan describes performance tests to be made with ionizing radiation measurement instrumentation designed and built for in-field assay at an excavation site. One instrument measures gross gamma-ray and neutron fields and the other identifies gamma-ray emitting radionuclides and also is capable of assaying for selected hazardous materials. These instruments will be operationally tested to verify that original specifications have been met and performance tested to establish and verify that they have the potential to function as intended at an excavation site

  7. Detection of food treated with ionizing radiation

    International Nuclear Information System (INIS)

    Delincee, H.

    1998-01-01

    Treatment of food with ionizing energy-'food irradiation'- is finally becoming reality in many countries. The benefits include an improvement in food hygiene, spoilage reduction and extension of shelf-life. Although properly irradiated food is safe and wholesome, consumers should be able to make their own free choice between irradiated and non-irradiated food. For this purpose labelling is indispensable. In order to check compliance with existing regulations, detection of radiation treatment by analysing the food itself is highly desirable. Significant progress has been made in recent years in developing analytical detection methods utilizing changes in food originating from the radiation treatment

  8. Instrument employing a charge flow transistor

    International Nuclear Information System (INIS)

    1981-01-01

    The invention concerns instruments employing charge-flow transistors that operate to sense a property in the surrounding environment. It is based on a particular sensor principle, thin-film conduction. The instruments described include a charge-flow transistor with semiconductor substrate, a source region, a drain region, a gate insulator, and a gapped electrode structure with a thin-film sensor material in the gap. The sensor material has an electrical conductance that is sensitive to a property of the ambient environment and has a surface conductance that differs substantially from its bulk conductance. The main object is to provide a low-cost instrument for early-warning fire-detection devices: in this case the property detected would be the products of combustion. Other properties that can be sensed include gases or vapors, free radicals, vapor electromagnetic radiation, subatomic particles, atomic or molecular beams, changes in ambient pressure or temperature, the chemical composition and the electrochemical potential of a solution. (U.K.)

  9. Instrument employing a charge flow transistor

    Energy Technology Data Exchange (ETDEWEB)

    1981-03-11

    The invention concerns instruments employing charge-flow transistors that operate to sense a property in the surrounding environment. It is based on a particular sensor principle, thin-film conduction. The instruments described include a charge-flow transistor with semiconductor substrate, a source region, a drain region, a gate insulator, and a gapped electrode structure with a thin-film sensor material in the gap. The sensor material has an electrical conductance that is sensitive to a property of the ambient environment and has a surface conductance that differs substantially from its bulk conductance. The main object is to provide a low-cost instrument for early-warning fire-detection devices: in this case the property detected would be the products of combustion. Other properties that can be sensed include gases or vapors, free radicals, vapor electromagnetic radiation, subatomic particles, atomic or molecular beams, changes in ambient pressure or temperature, the chemical composition and the electrochemical potential of a solution.

  10. Radiation sensitive area detection device and method

    Science.gov (United States)

    Carter, Daniel C. (Inventor); Hecht, Diana L. (Inventor); Witherow, William K. (Inventor)

    1991-01-01

    A radiation sensitive area detection device for use in conjunction with an X ray, ultraviolet or other radiation source is provided which comprises a phosphor containing film which releases a stored diffraction pattern image in response to incoming light or other electromagnetic wave. A light source such as a helium-neon laser, an optical fiber capable of directing light from the laser source onto the phosphor film and also capable of channelling the fluoresced light from the phosphor film to an integrating sphere which directs the light to a signal processing means including a light receiving means such as a photomultiplier tube. The signal processing means allows translation of the fluoresced light in order to detect the original pattern caused by the diffraction of the radiation by the original sample. The optical fiber is retained directly in front of the phosphor screen by a thin metal holder which moves up and down across the phosphor screen and which features a replaceable pinhole which allows easy adjustment of the resolution of the light projected onto the phosphor film. The device produces near real time images with high spatial resolution and without the distortion that accompanies prior art devices employing photomultiplier tubes. A method is also provided for carrying out radiation area detection using the device of the invention.

  11. Silicon solid state devices and radiation detection

    CERN Document Server

    Leroy, Claude

    2012-01-01

    This book addresses the fundamental principles of interaction between radiation and matter, the principles of working and the operation of particle detectors based on silicon solid state devices. It covers a broad scope with respect to the fields of application of radiation detectors based on silicon solid state devices from low to high energy physics experiments including in outer space and in the medical environment. This book covers stateof- the-art detection techniques in the use of radiation detectors based on silicon solid state devices and their readout electronics, including the latest developments on pixelated silicon radiation detector and their application.

  12. The development of special equipment amplitude detection instrument based on DSP

    International Nuclear Information System (INIS)

    Dai Sidan; Chen Ligang; Lan Peng; Wang Huiting; Zhang Liangxu; Wang Lin

    2014-01-01

    Development and industrial application of special equipment plays an important role in the development of nuclear energy process. Equipment development process need to do a lot of tests, amplitude detection is a key test,it can analysis the device's electromechanical and physical properties. In the industrial application, the amplitude detection can effectively reflect the operational status of the current equipment, the equipment can also be a certain degree of fault diagnosis, identify problems in a timely manner. The main development target in this article is amplitude detection of special equipment. This article describes the development of special equipment amplitude detection instrument. The instrument uses a digital signal processor (DSP) as the central processing unit, and uses the DSP + CPLD + high-speed AD technology to build a complete set of high-precision signal acquisition and analysis processing systems, rechargeable lithium battery as the powered device. It can do a online monitoring of special equipment amplitude, speed parameters by acquiring and analysing the tachometer signal in the special equipment, and locally display through the LCD screen. (authors)

  13. Tamper indicating radiation surveillance instrumentation

    International Nuclear Information System (INIS)

    Chambers, W.H.; Ney, J.F.

    1975-01-01

    Prototype personnel and shipping dock portal monitors suitable for unattended use were fabricated and tested. The requirement for continuous operation with only periodic inspection along with a desire for minimum costs and minimum interference with normal plant operation imposed unique design constraints. The design, operation, and performance of the detection and data recording instrumentation are described, as well as the tamper indicating techniques required to protect the collected data. The essential elements of either of the two instruments include a gamma detector array, signal conditioning electronics, digital alarm logic circuitry, power supplies, a microwave occupancy monitor, surveillance camera, irreversible electromechanical counters, and the appropriate tamper indicating envelope protecting these elements. Attempts to penetrate the tamper indicating envelope require material removal, and undetectable repair is very difficult, if not impossible. The techniques for joining major subassemblies and providing unique seals are also described. The personnel doorway uses a double pole array of NaI(Tl) detectors, and outputs are taken from a single channel pulse height analyzer with a window set at 60 to 250 keV and the lower level discriminator at greater than 60 keV. A sliding interval counter is used to make comparisons to an accumulated background at the 4sigma level. Logic design, sensitivity for special nuclear materials, false alarm data, and test procedures are described in detail. The shipping dock monitor had different design constraints and therefore uses a single, long, cylindrical plastic scintillator. Some differences in signal conditioning and processing are also described. (auth)

  14. Collection of radiation resistant characteristics reports for instruments and materials in high dose rate environment

    International Nuclear Information System (INIS)

    Kusano, Joichi

    2008-03-01

    This document presents the collected official reports of radiation irradiation study for the candidate materials to be used in high dose rate environment as J-PARC facility. The effect of radiation damage by loss-beam or secondary particle beam of the accelerators influences the performance and the reliability of various instruments. The knowledge on the radiation resistivity of the materials is important to estimate the life of the equipments, the maintenance interval and dose evaluation for the personnel at the maintenance period. The radiation damage consists with mechanical property, electrical property and gas-evolution property. (author)

  15. Passive radiation detection using optically active CMOS sensors

    Science.gov (United States)

    Dosiek, Luke; Schalk, Patrick D.

    2013-05-01

    Recently, there have been a number of small-scale and hobbyist successes in employing commodity CMOS-based camera sensors for radiation detection. For example, several smartphone applications initially developed for use in areas near the Fukushima nuclear disaster are capable of detecting radiation using a cell phone camera, provided opaque tape is placed over the lens. In all current useful implementations, it is required that the sensor not be exposed to visible light. We seek to build a system that does not have this restriction. While building such a system would require sophisticated signal processing, it would nevertheless provide great benefits. In addition to fulfilling their primary function of image capture, cameras would also be able to detect unknown radiation sources even when the danger is considered to be low or non-existent. By experimentally profiling the image artifacts generated by gamma ray and β particle impacts, algorithms are developed to identify the unique features of radiation exposure, while discarding optical interaction and thermal noise effects. Preliminary results focus on achieving this goal in a laboratory setting, without regard to integration time or computational complexity. However, future work will seek to address these additional issues.

  16. Organic materials and devices for detecting ionizing radiation

    Science.gov (United States)

    Doty, F Patrick [Livermore, CA; Chinn, Douglas A [Livermore, CA

    2007-03-06

    A .pi.-conjugated organic material for detecting ionizing radiation, and particularly for detecting low energy fission neutrons. The .pi.-conjugated materials comprise a class of organic materials whose members are intrinsic semiconducting materials. Included in this class are .pi.-conjugated polymers, polyaromatic hydrocarbon molecules, and quinolates. Because of their high resistivities (.gtoreq.10.sup.9 ohmcm), these .pi.-conjugated organic materials exhibit very low leakage currents. A device for detecting and measuring ionizing radiation can be made by applying an electric field to a layer of the .pi.-conjugated polymer material to measure electron/hole pair formation. A layer of the .pi.-conjugated polymer material can be made by conventional polymer fabrication methods and can be cast into sheets capable of covering large areas. These sheets of polymer radiation detector material can be deposited between flexible electrodes and rolled up to form a radiation detector occupying a small volume but having a large surface area. The semiconducting polymer material can be easily fabricated in layers about 10 .mu.m to 100 .mu.m thick. These thin polymer layers and their associated electrodes can be stacked to form unique multi-layer detector arrangements that occupy small volume.

  17. Advanced concepts in multi-dimensional radiation detection and imaging

    International Nuclear Information System (INIS)

    Vetter, Kai; Barnowski, Ross; Pavlovsky, Ryan; Haefner, Andy; Torii, Tatsuo; Shikaze, Yoshiaki; Sanada, Yukihisa

    2016-01-01

    Recent developments in the detector fabrication, signal readout, and data processing enable new concepts in radiation detection that are relevant for applications ranging from fundamental physics to medicine as well as nuclear security and safety. We present recent progress in multi-dimensional radiation detection and imaging in the Berkeley Applied Nuclear Physics program. It is based on the ability to reconstruct scenes in three dimensions and fuse it with gamma-ray image information. We are using the High-Efficiency Multimode Imager HEMI in its Compton imaging mode and combining it with contextual sensors such as the Microsoft Kinect or visual cameras. This new concept of volumetric imaging or scene data fusion provides unprecedented capabilities in radiation detection and imaging relevant for the detection and mapping of radiological and nuclear materials. This concept brings us one step closer to the seeing the world with gamma-ray eyes. (author)

  18. New technique for alpha particles detection

    International Nuclear Information System (INIS)

    Morsy, A.A.; Khattab, F.M.

    1998-01-01

    Man possesses no biological sensors of ionizing radiation as a consequence he must depend entirely on instrumentation for the detection and measurement of radiation. The recent discovery of the solid state nuclear track detection ( SSNTD ) techniques and its advantages over other dosimeters made them a useful tool for radiation dosimetry. This work is devoted to review and illustrate the application of SSNTD technique in some branches of science and technology specially the newly produced TASTRAK obtained from Track Analysis System Limited, Bristol, UK. The detector is successfully irradiated, chemically etched and calibrated for the aim of the Alpha radiation dosimetry

  19. Conference on instrumental activation analysis IAA 92

    International Nuclear Information System (INIS)

    Frana, J.; Obrusnik, I.

    1992-05-01

    The publication contains 26 abstracts primarily concerned with neutron activation analysis, although other analytical techniques based on X-ray fluorescence analysis, PIXE, PIGE, RBS are also included. Some contributions deal with aspects of quality practice and assurance in radioanalytical laboratories, with marketing of instrumental neutron activation analysis services, with hard- and software aspects of radiation detection, etc. (Z.S.)

  20. Development of mobile radiation detection system against nuclear terrorism in Korea

    International Nuclear Information System (INIS)

    Kwak, Sung-Woo; Chang, Sung-Soon; Yoo, Ho-Sik

    2011-01-01

    A fixed radiation portal monitors (RPM) deployed at border, seaport, airport or key traffic checkpoints has played an important role in preventing the illicit trafficking and transport of nuclear and radioactive materials. However, the RPM usually is large and heavy and can't easily be moved to a different location. An intelligent terrorist may also circumvent the fixed RPM to avoid being detected. These reasons motivate us to develop a mobile radiation detection system. The objective of this paper is to report our experience on developing the mobile radiation detection system for the search and detection of nuclear and radioactive materials during road transport. Measurements were performed at various speeds and distances between the radioactive isotope (RI) transporting car and the measurement car. Results of our measurements and the detection limits of the system is described in this paper. The mobile radiation detection system developed should contribute to defending public's health and safety and the environment against nuclear and radiological terrorism by detecting nuclear or radioactive material hidden illegally in a vehicle. (author)

  1. Detection of gamma-neutron radiation by solid-state scintillation detectors. Detection of gamma-neutron radiation by novel solid-state scintillation detectors

    Energy Technology Data Exchange (ETDEWEB)

    Ryzhikov, V.; Grinyov, B.; Piven, L.; Onyshchenko, G.; Sidletskiy, O. [Institute for Scintillation Materials of the NAS of Ukraine, Kharkov, (Ukraine); Naydenov, S. [Institute for Single Crystals of the National Academy of Sciences of Ukraine, Kharkov, (Ukraine); Pochet, T. [DETEC-Europe, Vannes (France); Smith, C. [Naval Postgraduate School, Monterey, CA (United States)

    2015-07-01

    It is known that solid-state scintillators can be used for detection of both gamma radiation and neutron flux. In the past, neutron detection efficiencies of such solid-state scintillators did not exceed 5-7%. At the same time it is known that the detection efficiency of the gamma-neutron radiation characteristic of nuclear fissionable materials is by an order of magnitude higher than the efficiency of detection of neutron fluxes alone. Thus, an important objective is the creation of detection systems that are both highly efficient in gamma-neutron detection and also capable of exhibiting high gamma suppression for use in the role of detection of neutron radiation. In this work, we present the results of our experimental and theoretical studies on the detection efficiency of fast neutrons from a {sup 239}Pu-Be source by the heavy oxide scintillators BGO, GSO, CWO and ZWO, as well as ZnSe(Te, O). The most probable mechanism of fast neutron interaction with nuclei of heavy oxide scintillators is the inelastic scattering (n, n'γ) reaction. In our work, fast neutron detection efficiencies were determined by the method of internal counting of gamma-quanta that emerge in the scintillator from (n, n''γ) reactions on scintillator nuclei with the resulting gamma energies of ∼20-300 keV. The measured efficiency of neutron detection for the scintillation crystals we considered was ∼40-50 %. The present work included a detailed analysis of detection efficiency as a function of detector and area of the working surface, as well as a search for new ways to create larger-sized detectors of lower cost. As a result of our studies, we have found an unusual dependence of fast neutron detection efficiency upon thickness of the oxide scintillators. An explanation for this anomaly may involve the competition of two factors that accompany inelastic scattering on the heavy atomic nuclei. The transformation of the energy spectrum of neutrons involved in the (n, n

  2. Innovative instrumentation for VVERs based in non-invasive techniques

    International Nuclear Information System (INIS)

    Jeanneau, H.; Favennec, J.M.; Tournu, E.; Germain, J.L.

    2000-01-01

    Nuclear power plants such as VVERs can greatly benefit from innovative instrumentation to improve plant safety and efficiency. In recent years innovative instrumentation has been developed for PWRs with the aim of providing additional measurements of physical parameters on the primary and secondary circuits: the addition of new instrumentation is made possible by using non-invasive techniques such as ultrasonics and radiation detection. These innovations can be adapted for upgrading VVERs presently in operation and also in future VVERs. The following innovative instrumentation for the control, monitoring or testing at VVERs is described: 1. instrumentation for more accurate primary side direct measurements (for a better monitoring of the primary circuit); 2. instrumentation to monitor radioactivity leaks (for a safer plant); 3. instrumentation-related systems to improve the plant efficiency (for a cheaper kWh)

  3. Study of the casting speedy radiation-detection system

    International Nuclear Information System (INIS)

    Tan Xiaochun; Huang Junqing; Shi Xianbei; Zhao Gang; Wang Liping

    2001-01-01

    The paper introduces the design of the launching speedy radiation-detection system. It consists of launcher, semiconductor detector, microprocessor and communicator. It can give the intensity, position, time of radiation. The paper discusses the function, composition, principle, speciality and technical problem of this system

  4. Detecting Illicit Nuclear Materials

    International Nuclear Information System (INIS)

    Kouzes, Richard T.

    2005-01-01

    The threat that weapons of mass destruction might enter the United States has led to a number of efforts for the detection and interdiction of nuclear, radiological, chemical, and biological weapons at our borders. There have been multiple deployments of instrumentation to detect radiation signatures to interdict radiological material, including weapons and weapons material worldwide

  5. Radiation sensitive devices and systems for detection of radioactive materials and related methods

    Science.gov (United States)

    Kotter, Dale K

    2014-12-02

    Radiation sensitive devices include a substrate comprising a radiation sensitive material and a plurality of resonance elements coupled to the substrate. Each resonance element is configured to resonate responsive to non-ionizing incident radiation. Systems for detecting radiation from a special nuclear material include a radiation sensitive device and a sensor located remotely from the radiation sensitive device and configured to measure an output signal from the radiation sensitive device. In such systems, the radiation sensitive device includes a radiation sensitive material and a plurality of resonance elements positioned on the radiation sensitive material. Methods for detecting a presence of a special nuclear material include positioning a radiation sensitive device in a location where special nuclear materials are to be detected and remotely interrogating the radiation sensitive device with a sensor.

  6. Optical fiber applied to radiation detection

    Energy Technology Data Exchange (ETDEWEB)

    Junior, Francisco A.B.; Costa, Antonella L.; Oliveira, Arno H. de; Vasconcelos, Danilo C., E-mail: fanbra@yahoo.com.br, E-mail: antonella@nuclear.ufmg.br, E-mail: heeren@nuclear.ufmg.br, E-mail: danilochagas@yahoo.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Escola de Engenharia. Departamento de Engenharia Nuclear

    2015-07-01

    In the last years, the production of optical fibers cables has make possible the development of a range of spectroscopic probes for in situ analysis performing beyond nondestructive tests, environmental monitoring, security investigation, application in radiotherapy for dose monitoring, verification and validation. In this work, a system using an optical fiber cable to light signal transmission from a NaI(Tl) radiation detector is presented. The innovative device takes advantage mainly of the optical fibers small signal attenuation and immunity to electromagnetic interference to application for radiation detection systems. The main aim was to simplify the detection system making it to reach areas where the conventional device cannot access due to its lack of mobility and external dimensions. Some tests with this innovative system are presented and the results stimulate the continuity of the researches. (author)

  7. Cosmic radiation

    Energy Technology Data Exchange (ETDEWEB)

    Capdevielle, J N

    1984-01-01

    First, the different instruments and techniques of cosmic particle detection are presented. Then the passage of the cosmic particles through the atmosphere is studied: electrons, photons, muons. The collective behavior of the different categories is also studied, the electromagnetic cascade is distinguished from the hadron cascade. Through the principal physical properties of the radiation and the medium, the ''mean'' aspects of the radiation are then successively dealt with out of the atmosphere, at different altitudes until the sea level, then at great depths. A chapter is devoted to cosmic radiation of more than 10,000 GeV, studied separately. Then solar radiation in universe is studied through their propagation in solar system and their origin. At last, the cosmic radiation effects are studied in environment (cosmic biophysics) and some applications of cosmic radiation are presented.

  8. Development of an alpha scattering instrument for heavy element detection in surface materials. Final report

    International Nuclear Information System (INIS)

    Turkevich, A.L.; Economou, T.; Blume, E.; Anderson, W.

    1974-12-01

    The development and characteristics of a portable instrument for detecting and measuring the amounts of lead in painted surfaces are discussed. The instrument is based on the ones used with the alpha scattering experiment on the Surveyor lunar missions. The principles underlying the instrument are described. It is stated that the performance tests of the instrument were satisfactory. (auth)

  9. Proposal of secure camera-based radiation warning system for nuclear detection

    International Nuclear Information System (INIS)

    Tsuchiya, Ken'ichi; Kurosawa, Kenji; Akiba, Norimitsu; Kakuda, Hidetoshi; Imoto, Daisuke; Hirabayashi, Manato; Kuroki, Kenro

    2016-01-01

    Counter-terrorisms against radiological and nuclear threat are significant issues toward Tokyo 2020 Olympic and Paralympic Games. In terms of cost benefit, it is not easy to build a warning system for nuclear detection to prevent a Dirty Bomb attack (dispersion of radioactive materials using a conventional explosive) or a Silent Source attack (hidden radioactive materials) from occurring. We propose a nuclear detection system using the installed secure cameras. We describe a method to estimate radiation dose from noise pattern in CCD images caused by radiation. Some dosimeters under neutron and gamma-ray irradiations (0.1mSv-100mSv) were taken in CCD video camera. We confirmed amount of noise in CCD images increased in radiation exposure. The radiation detection using CMOS in secure cameras or cell phones has been implemented. However, in this presentation, we propose a warning system including neutron detection to search shielded nuclear materials or radiation exposure devices using criticality. (author)

  10. Construction and operation of an improved radiation calibration facility at Brookhaven National Laboratory. Environmental assessment

    International Nuclear Information System (INIS)

    1994-10-01

    Calibration of instruments used to detect and measure ionizing radiation has been conducted over the last 20 years at Brookhaven National Laboratory's (BNL) Radiation Calibration Facility, Building 348. Growth of research facilities, projects in progress, and more stringent Department of Energy (DOE) orders which involve exposure to nuclear radiation have placed substantial burdens on the existing radiation calibration facility. The facility currently does not meet the requirements of DOE Order 5480.4 or American National Standards Institute (ANSI) N323-1978, which establish calibration methods for portable radiation protection instruments used in the detection and measurement of levels of ionizing radiation fields or levels of radioactive surface contaminations. Failure to comply with this standard could mean instrumentation is not being calibrated to necessary levels of sensitivity. The Laboratory has also recently obtained a new neutron source and gamma beam irradiator which can not be made operational at existing facilities because of geometry and shielding inadequacies. These sources are needed to perform routine periodic calibrations of radiation detecting instruments used by scientific and technical personnel and to meet BNL's substantial increase in demand for radiation monitoring capabilities. To place these new sources into operation, it is proposed to construct an addition to the existing radiation calibration facility that would house all calibration sources and bring BNL calibration activities into compliance with DOE and ANSI standards. The purpose of this assessment is to identify potential significant environmental impacts associated with the construction and operation of an improved radiation calibration facility at BNL

  11. Instrument for the detection of meteors in the infrared

    Science.gov (United States)

    Svedhem, H.; Koschny, D.; Ter Haar, J.

    2014-07-01

    The flux of interplanetary particles in the size range 2 mm to 20 m is poorly constrained due to insufficient data --- the larger bodies may be observed remotely by ground-based or space-based telescopes and the smaller particles are measured by in-situ impact detectors in space or by meteor cameras from ground. An infrared video rate imager in Earth orbit would enable a systematic characterization for an extended period, day and night, of the flux in this range by monitoring the bright meteor/fireball generated during atmospheric entry. Due to the low flux of meteoroids in this range a very large detector is required. With this method a large portion of the Earth atmosphere is in fact used as a huge detector. Such an instrument has never flown in Earth orbit. The only sensors of a similar kind fly on US defense satellites for monitoring launches of ballistic missiles. The data from these sensors, however, is largely inaccessible to scientists. The knowledge on emission of light by meteors/bolides at infrared wavelengths is very limited while it can be suspected that the continuum emission from meteors/bolides have stronger emission at infrared wavelengths than in the visible due to the likely low temperatures of these events. At the same time line emission is dominating over the continuum in the visible so it is not clear how this will compare with the continuum in the infrared. We have developed a bread-board version of an IR video rate camera, the SPOSH-IR. The instrument is based on an earlier technology development, SPOSH --- Smart Panoramic Optical Sensor Head, for operation in the visible range, but with the sensor replaced by a cooled IR detector and new infrared optics. The earlier work has proven the concept of the instrument and of automatic detection of meteors/bolides in the visible wavelength range. The new hardware has been built by Jena-Optronik, Jena, Germany and has been tested during several meteor showers in the Netherlands and at ESA's OGS

  12. Recent developments in analytical detection methods for radiation processed foods

    International Nuclear Information System (INIS)

    Wu Jilan

    1993-01-01

    A short summary of the programmes of 'ADMIT' (FAO/IAEA) and the developments in analytical detection methods for radiation processed foods has been given. It is suggested that for promoting the commercialization of radiation processed foods and controlling its quality, one must pay more attention to the study of analytical detection methods of irradiated food

  13. Nuclear Forensics and Radiochemistry: Radiation Detection

    Energy Technology Data Exchange (ETDEWEB)

    Rundberg, Robert S. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-11-08

    Radiation detection is necessary for isotope identification and assay in nuclear forensic applications. The principles of operation of gas proportional counters, scintillation counters, germanium and silicon semiconductor counters will be presented. Methods for calibration and potential pitfalls in isotope quantification will be described.

  14. Nuclear Forensics and Radiochemistry: Radiation Detection

    International Nuclear Information System (INIS)

    Rundberg, Robert S.

    2017-01-01

    Radiation detection is necessary for isotope identification and assay in nuclear forensic applications. The principles of operation of gas proportional counters, scintillation counters, germanium and silicon semiconductor counters will be presented. Methods for calibration and potential pitfalls in isotope quantification will be described.

  15. Radioactive check sources for alpha and beta sensitive radiological instrumentation

    International Nuclear Information System (INIS)

    Barnett, J.M.; Kane, J.E. II.

    1994-06-01

    Since 1991, the Westinghouse Hanford Company has examined the construction and use of alpha and beta radioactive check sources for calibrating instruments and for performing response checks of instruments used for operational and environmental radiation detection. The purpose of using a radioactive check source is to characterize the response of a radiation monitoring instrument in the presence of radioactivity. To accurately calibrate the instrument and check its response, the check source used must emulate as closely as possible the actual physical and isotopic conditions being monitored. The isotope employed and the physical methods used to fabricate the check source (among other factors) determine instrument response. Although information from applicable national and international standards, journal articles, books, and government documents was considered, empirical data collected is most valuable when considering the type of source to use for a particular application. This paper presents source construction methods, use considerations, and standard recommendations. The results of a Hanford Site evaluation of several types of alpha and beta sources are also given

  16. Method and circuit for stabilizing conversion gain of radiation detectors of a radiation detection system

    International Nuclear Information System (INIS)

    Stoub, E.W.

    1986-01-01

    A method is described for calibrating the gain of an array of radiation detectors of a radiation detection system comprising the steps of: (a) measuring in parallel for each radiation detector using a predetermined calibration point the energy map status, thereby obtaining an energy response vector whose elements correspond to the individual output of each radiation detector, each predetermined calibration point being a prescribed location corresponding to one of the radiation detectors; (b) multiplying that energy response vector with a predetermined deconvolution matrix, the deconvolution matrix being the inversion of a contribution matrix containing matrix elements C/sub IJ/, each such matrix element C/sub IJ/ of the contribution matrix representing the relative contribution level of a radiation detector j of the detection system for a point radiation source placed at a location i, thereby obtaining a gain vector product for the radiation detectors; (c) adjusting the gains of the radiation detectors with respect to the gain vector product such that a unity gain vector is essentially obtained; (d) measuring again the energy map status according to step (a); and (e) if the energy map status fails to essentially produce a unity gain vector repeat steps (a) to (d) until the energy map status substantially corresponds to unity

  17. Mineralogy and Astrobiology Detection Using Laser Remote Sensing Instrument

    Science.gov (United States)

    Abedin, M. Nurul; Bradley, Arthur T.; Sharma, Shiv K.; Misra, Anupam K.; Lucey, Paul G.; Mckay, Chistopher P.; Ismail, Syed; Sandford, Stephen P.

    2015-01-01

    A multispectral instrument based on Raman, laser-induced fluorescence (LIF), laser-induced breakdown spectroscopy (LIBS), and a lidar system provides high-fidelity scientific investigations, scientific input, and science operation constraints in the context of planetary field campaigns with the Jupiter Europa Robotic Lander and Mars Sample Return mission opportunities. This instrument conducts scientific investigations analogous to investigations anticipated for missions to Mars and Jupiter's icy moons. This combined multispectral instrument is capable of performing Raman and fluorescence spectroscopy out to a >100 m target distance from the rover system and provides single-wavelength atmospheric profiling over long ranges (>20 km). In this article, we will reveal integrated remote Raman, LIF, and lidar technologies for use in robotic and lander-based planetary remote sensing applications. Discussions are focused on recently developed Raman, LIF, and lidar systems in addition to emphasizing surface water ice, surface and subsurface minerals, organics, biogenic, biomarker identification, atmospheric aerosols and clouds distributions, i.e., near-field atmospheric thin layers detection for next robotic-lander based instruments to measure all the above-mentioned parameters. OCIS codes: (120.0280) Remote sensing and sensors; (130.0250) Optoelectronics; (280.3640) Lidar; (300.2530) Fluorescence, laser-induced; (300.6450) Spectroscopy, Raman; (300.6365) Spectroscopy, laser induced breakdown

  18. Origin, characteristics and detection of nuclear radiation

    International Nuclear Information System (INIS)

    Goettel, K.

    1975-06-01

    The report is an introduction into the physical principles of radiation protection. After a brief summary of the most significant experimental results and data on the atomic structure of the matter and after explaining the principles of atomic and nuclear structure, radioactive decay and its laws are dealt with. This is followed by a representation of the characteristics of nuclear radiation, its interaction with the matter as well as the biological effects. After a description of the measurement units for radioactivity and doses the most inportant methods for radiation detection and the principles of how detectors function are explained. (ORU/LN) [de

  19. Buried pipeline leak-detection technique and instruments using radioactive tracers

    International Nuclear Information System (INIS)

    Zhou Shuxuan; Lu Qingqian; Tang Yonghua

    1987-01-01

    For detecting and locating leaks on buried pipelines, a leak-detection technique and related instruments have been developed. Some quantity of fluid mixed with a radioactive tracer is injected. After the pipeline is cleaned, a leak-detector is put into and moves along the pipline to monitor the leaked radioactivity and to record both the radioactive signal and the time signal on a magnetic tape. From the signal curves, it can be judged whether there are any leaks on the pipeline and, if any, where they are

  20. The design of a simple portable γ ray detecting instrument based on MCU

    International Nuclear Information System (INIS)

    Liu Chunmei; Cao Wen; Zhang Jiang

    2008-01-01

    The internal composition of the γ ray detecting instrument based on MCU and the working of the real electric circuit are introduced. The single-chip microcomputer of PHILIPS is adopted as the micro-controller of the instrument, realizing such functions as counting input pulses within fixed time, data processing, liquid crystal display, keyboard interface, serial communication, etc. The instrument turns out to be low in work consumption, with relatively high degree of concentration and computerization, and is recommended for field operations. (authors)

  1. Instrumentation For Multiple Radiation Detection Based On Novel Mercurous Halides For Nuclear Planetology, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Radiation detectors that sense gamma and neutron radiation are critical to the exploration of planetary surface composition. Among the key technological challenges...

  2. Drone Detects Hotspots of Radiation and CO2 Outgassing

    Science.gov (United States)

    Takac, M.; Kletetschka, G.

    2016-12-01

    Market availability of environmental sensors and drones allow drones to become part of the education activities promoting environmental science both in high schools and grade schools. Here we provide one mode of drone operation for potential use in educational framework.Drone can carry devices that are capable of measuring various parameters of the environment. Commercial radiation and gas (CO2) sensors can be attached to the commercial drone. Our specific drone acquired data set of CO2 measurements over the natural outgassing of CO2 and another set of measurements over old uranium mine. Measurements of CO2 gave a poor signal to noise ratio. Its sensitivity, however, was enough to detect an increase in CO2 in the closed room with humans present compared to the fresh air outside. We could measure an increase of CO2 when directly over the source of natural CO2 outburst. Our data showed that CO2 concentration quickly dilutes in air few meters from the source to concentrations that are within the noise limit. However, the radiation measurements provided a map that correlates well with radiation survey obtained by ground measurements with more sophisticated instrument. We used the most common conventional drone, which is on the market and highly effective personal dosimeter, which can also be used for fire and rescue for its durability. Experimental field measurements were done at Třebsko site, where a map of radioactivity using standard spot measurements was already done. A field experiment was done in winter months when demand for the drone was higher due to cold and wet weather. We tested profiles and height versus the intensity of the recorded signal measurements. We consulted our results and ability to measure radioactivity with the regional fire-fighting units headquarters and verify the applicability and use of this technology for their needs.

  3. Highly sensitive detection of ionizing radiations by a photoluminescent uranyl organic framework

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Jian; Wang, Yaxing; Liu, Wei; Yin, Xuemiao; Chen, Lanhua; Diwu, Juan; Chai, Zhifang; Wang, Shuao [School for Radiological and interdisciplinary Sciences (RAD-X) and Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Soochow University, Suzhou (China); Zou, Youming [High Magnetic Field Laboratory, Chinese Academy of Sciences, Hefei, Anhui (China); Albrecht-Schmitt, Thomas E. [Department of Chemistry and Biochemistry, Florida State University, Tallahassee, FL (United States); Liu, Guokui [Chemical Sciences and Engineering Division, Argonne National Laboratory, Argonne, IL (United States)

    2017-06-19

    Precise detection of low-dose X- and γ-radiations remains a challenge and is particularly important for studying biological effects under low-dose ionizing radiation, safety control in medical radiation treatment, survey of environmental radiation background, and monitoring cosmic radiations. We report here a photoluminescent uranium organic framework, whose photoluminescence intensity can be accurately correlated with the exposure dose of X- or γ-radiations. This allows for precise and instant detection of ionizing radiations down to the level of 10{sup -4} Gy, representing a significant improvement on the detection limit of approximately two orders of magnitude, compared to other chemical dosimeters reported up to now. The electron paramagnetic resonance analysis suggests that with the exposure to radiations, the carbonyl double bonds break affording oxo-radicals that can be stabilized within the conjugated uranium oxalate-carboxylate sheet. This gives rise to a substantially enhanced equatorial bonding of the uranyl(VI) ions as elucidated by the single-crystal structure of the γ-ray irradiated material, and subsequently leads to a very effective photoluminescence quenching through phonon-assisted relaxation. The quenched sample can be easily recovered by heating, enabling recycled detection for multiple runs. (copyright 2017 Wiley-VCH Verlag GmbH and Co. KGaA, Weinheim)

  4. Rubella virus detection by ELISA method in exposed radiation workers

    International Nuclear Information System (INIS)

    Wu Jianmei; Zhu Bo; Zhu Youming; Shao Jinhui; Wu Weiping; Han Jinxiang

    2005-01-01

    Objective: A rapid diagnosis method was developed to detect Rubella virus infection in radiation workers. Methods: Modified ELISA method was used to detect the level of lgG and lgM antibodies in 514 in Jinan district. Results: 90.47% of 514 cases was shown to be resistant against Rubella virus; 6.42% were sensitive type; 0.78% belonged to be reinfected. Conclusion: Detection of Rubella virus in exposed radiation workers was imperative, and vaccine against Rubella virus was also needed to eliminate the infection risk. (authors)

  5. Hand-held, mechanically cooled, radiation detection system for gamma-ray spectroscopy

    Science.gov (United States)

    Burks, Morgan Thomas; Eckels, Joel Del

    2010-06-08

    In one embodiment, a radiation detection system is provided including a radiation detector and a first enclosure encapsulating the radiation detector, the first enclosure including a low-emissivity infra-red (IR) reflective coating used to thermally isolate the radiation detector. Additionally, a second enclosure encapsulating the first enclosure is included, the first enclosure being suspension mounted to the second enclosure. Further, a cooler capable of cooling the radiation detector is included. Still yet, a first cooling interface positioned on the second enclosure is included for coupling the cooler and the first enclosure. Furthermore, a second cooling interface positioned on the second enclosure and capable of coupling the first enclosure to a cooler separate from the radiation detection system is included. Other embodiments are also presented.

  6. The problem of the detection threshold in radiation measurement

    International Nuclear Information System (INIS)

    Rose, E.; Wueneke, C.D.

    1983-01-01

    In all cases encountered in practical radiation measurement, the basic problem is to differentiate between the lowest measured value and the zero value (background, natural background radiation, etc.). For this purpose, on the mathematical side, tests based on hypotheses are to be applied. These will show the probability of differentiation between two values having the same random spread. By means of these tests and the corresponding error theory, a uniform treatment of the subject, applicable to all problems relating to measuring technique alike, can be found. Two basic concepts are found in this process, which have to be defined in terms of semantics and nomenclature: Decision threshold and detection threshold, or 'minimum detectable mean value'. At the decision threshold, one has to decide (with a given statistical error probability) whether a measured value is to be attributed to the background radiation, accepting the zero hypothesis, or whether this value differs significantly from the background radiation (error of 1rst kind). The minimum detectable mean value is the value which, with a given decision threshold, can be determined with sufficient significance to be a measured value and thus cannot be mistaken as background radiation (alternative hypothesis, error of 2nd kind). Normally, the two error types are of equal importance. It may happen, however, that one type of error gains more importance, depending on the approach. (orig.) [de

  7. Evaluation of Differences in Response of DOD Portable Instruments and Solid-State Detectors used by MEXT for Measurement of External Radiations with Attention to the Cosmic Radiation Component

    Science.gov (United States)

    2014-03-01

    Defense Threat Reduction Agency 8725 John J. Kingman Road, MS-6201 Fort Belvoir, VA 22060-6201...Attention to the Cosmic Radiation Component DISTRIBUTION A. Approved for public release: distribution is unlimited March 2014...Portable Instruments and Solid-State Detectors used by MEXT for Measurement of External Radiations with Attention to the Cosmic Radiation Component 5a

  8. A Method for Improving Reliability of Radiation Detection using Deep Learning Framework

    International Nuclear Information System (INIS)

    Chang, Hojong; Kim, Tae-Ho; Han, Byunghun; Kim, Hyunduk; Kim, Ki-duk

    2017-01-01

    Radiation detection is essential technology for overall field of radiation and nuclear engineering. Previously, technology for radiation detection composes of preparation of the table of the input spectrum to output spectrum in advance, which requires simulation of numerous predicted output spectrum with simulation using parameters modeling the spectrum. In this paper, we propose new technique to improve the performance of radiation detector. The software in the radiation detector has been stagnant for a while with possible intrinsic error of simulation. In the proposed method, to predict the input source using output spectrum measured by radiation detector is performed using deep neural network. With highly complex model, we expect that the complex pattern between data and the label can be captured well. Furthermore, the radiation detector should be calibrated regularly and beforehand. We propose a method to calibrate radiation detector using GAN. We hope that the power of deep learning may also reach to radiation detectors and make huge improvement on the field. Using improved radiation detector, the reliability of detection would be confident, and there are many tasks remaining to solve using deep learning in nuclear engineering society.

  9. Nuclear instrumentation systems in prototype fast breeder reactor

    International Nuclear Information System (INIS)

    Vijayakumaran, P.M.; Nagaraj, C.P.; Paramasivan-Pillai, C.; Ramakrishnan, R.; Sivaramakrishna, M.

    2004-01-01

    The nuclear instrumentation systems of the Prototype Fast Breeder Reactor (PFBR) primarily comprise of global Neutron Flux Monitoring, Failed Fuel Detection and Location, Radiation Monitoring and Post-Accident Monitoring. High temperature fission chambers are provided at in-vessel locations for monitoring neutron flux. Failed fuel detection and location is by monitoring the cover gas for fission gases and primary sodium for delayed neutrons. Signals of the core monitoring detectors are used to initiate SCRAM (safety action) to protect the reactor from various postulated initiating events. Radiation levels in all potentially radioactive areas are monitored to act as an early warning system to keep the release of radioactivity to the environment and exposure to personnel well below the permissible limits. Fission Chambers and Gamma Ionisation Chambers are located in the reactor vault concrete for monitoring the neutron flux and gamma radiation levels during and after an accident. (authors)

  10. ANOLE Portable Radiation Detection System Field Test and Evaluation Campaign

    International Nuclear Information System (INIS)

    Hodge, Chris A.

    2007-01-01

    Handheld, backpack, and mobile sensors are elements of the Global Nuclear Detection System for the interdiction and control of illicit radiological and nuclear materials. They are used by the U.S. Department of Homeland Security (DHS) and other government agencies and organizations in various roles for border protection, law enforcement, and nonproliferation monitoring. In order to systematically document the operational performance of the common commercial off-the-shelf portable radiation detection systems, the DHS Domestic Nuclear Detection Office conducted a test and evaluation campaign conducted at the Nevada Test Site from January 18 to February 27, 2006. Named 'Anole', it was the first test of its kind in terms of technical design and test complexities. The Anole test results offer users information for selecting appropriate mission-specific portable radiation detection systems. The campaign also offered manufacturers the opportunity to submit their equipment for independent operationally relevant testing to subsequently improve their detector performance. This paper will present the design, execution, and methodologies of the DHS Anole portable radiation detection system test campaign

  11. Nanopositioning techniques development for synchrotron radiation instrumentation applications at the Advanced Photon Source

    International Nuclear Information System (INIS)

    Shu Deming

    2010-01-01

    At modern synchrotron radiation sources and beamlines, high-precision positioning techniques present a significant opportunity to support state-of-the-art synchrotron radiation research. Meanwhile, the required instrument positioning performance and capabilities, such as resolution, dynamic range, repeatability, speed, and multiple axes synchronization are exceeding the limit of commercial availability. This paper presents the current nanopositioning techniques developed for the Argonne Center for Nanoscale Materials (CNM)/Advanced Photon Source (APS) hard x-ray nanoprobe and high-resolution x-ray monochromators and analyzers for the APS X-ray Operations and Research (XOR) beamlines. Future nanopositioning techniques to be developed for the APS renewal project will also be discussed.

  12. Detection of electromagnetic radiation using nonlinear materials

    Science.gov (United States)

    Hwang, Harold Y.; Liu, Mengkun; Averitt, Richard D.; Nelson, Keith A.; Sternbach, Aaron; Fan, Kebin

    2016-06-14

    An apparatus for detecting electromagnetic radiation within a target frequency range is provided. The apparatus includes a substrate and one or more resonator structures disposed on the substrate. The substrate can be a dielectric or semiconductor material. Each of the one or more resonator structures has at least one dimension that is less than the wavelength of target electromagnetic radiation within the target frequency range, and each of the resonator structures includes at least two conductive structures separated by a spacing. Charge carriers are induced in the substrate near the spacing when the resonator structures are exposed to the target electromagnetic radiation. A measure of the change in conductivity of the substrate due to the induced charge carriers provides an indication of the presence of the target electromagnetic radiation.

  13. Portable radiation meters developed in Boris Kidric Institute

    International Nuclear Information System (INIS)

    Sobajic, V.; Smelcerovic, M.

    1989-01-01

    Portable meters designed for X and gamma radiation measurements and beta detection are described. An instrument using ionization chamber is developed with new type of electrometer amplifier. It is designed for precise and reliable exposure and exposure rate measurements. Another instrument with GM counters covers 8 linear ranges: from background up to 10 Sv/h. Some specific solutions and basic measurement characteristics of these instruments are presented (author)

  14. Detection of gamma-ray bursts from Andromeda

    International Nuclear Information System (INIS)

    Bulik, Tomasz; Coppi, Paolo S.; Lamb, Donald Q.

    1996-01-01

    If gamma-ray bursts originate in a corona around the Milky Way, it should also be possible to detect them from a similar corona around Andromeda. Adopting a simple model of high velocity neutron star corona, we evaluate the ability of instruments on existing missions to detect an excess of bursts toward Andromeda. We also calculate the optimal properties of an instrument designed to detect such an excess. We find that if the bursts radiate isotropically, an experiment with a sampling distance d max > or approx. 500 kpc could detect a significant excess of bursts in the direction of Andromeda in a few years of observation. If the radiation is beamed along the neutron star's direction of motion, an experiment with d max > or approx. 800 kpc would detect such an excess in a similar amount of time, provided that the width of the beam is greater than 10 deg. Lack of an excess toward Andromeda would therefore be compelling evidence that the bursts are cosmological in origin if made by an instrument at least 50 times more sensitive than BATSE, given current constraints on Galactic corona models. Comparisons with detailed dynamical calculations of the spatial distribution of high velocity neutron stars in the coronae around the Milky Way and Andromeda confirm these conclusions

  15. Instrument evaluation no. 9. Mini-instruments dose rate meter type 5 - 1OR

    International Nuclear Information System (INIS)

    Iles, W.J.; Burgess, P.H.; Callowhill, K.

    1977-04-01

    This instrument is a portable, battery powered dose rate meter covering the dose rate range from 0 to 200 mrad h -1 . The instrument is designed to measure X- and γ-radiation dose rates over the energy range from 45 keV to 3 MeV. The radiation detector of the instrument is a GM tube with a specially designed energy compensation sheath. This detector is incorporated in a probe connected to the rate meter by an extensible cable which may be either hand-held or clipped on to the top of the instrument case. All the measurements in this report have been taken with the long axis of the probe normal to the direction of the incident radiation, the orientation recommended by the manufacturer. The information is given under the following headings: facilities and controls; radiation characteristics; electrical characteristics; effect of ambient temperature; mechanical characteristics; summary of performance; conclusions. (U.K.)

  16. Designing Successful Next-Generation Instruments to Detect the Epoch of Reionization

    Science.gov (United States)

    Thyagarajan, Nithyanandan; Hydrogen Epoch of Reionization Array (HERA) team, Murchison Widefield Array (MWA) team

    2018-01-01

    The Epoch of Reionization (EoR) signifies a period of intense evolution of the Inter-Galactic Medium (IGM) in the early Universe caused by the first generations of stars and galaxies, wherein they turned the neutral IGM to be completely ionized by redshift ≥ 6. This important epoch is poorly explored to date. Measurement of redshifted 21 cm line from neutral Hydrogen during the EoR is promising to provide the most direct constraints of this epoch. Ongoing experiments to detect redshifted 21 cm power spectrum during reionization, including the Murchison Widefield Array (MWA), Precision Array for Probing the Epoch of Reionization (PAPER), and the Low Frequency Array (LOFAR), appear to be severely affected by bright foregrounds and unaccounted instrumental systematics. For example, the spectral structure introduced by wide-field effects, aperture shapes and angular power patterns of the antennas, electrical and geometrical reflections in the antennas and electrical paths, and antenna position errors can be major limiting factors. These mimic the 21 cm signal and severely degrade the instrument performance. It is imperative for the next-generation of experiments to eliminate these systematics at their source via robust instrument design. I will discuss a generic framework to set cosmologically motivated antenna performance specifications and design strategies using the Precision Radio Interferometry Simulator (PRISim) -- a high-precision tool that I have developed for simulations of foregrounds and the instrument transfer function intended primarily for 21 cm EoR studies, but also broadly applicable to interferometer-based intensity mapping experiments. The Hydrogen Epoch of Reionization Array (HERA), designed in-part based on this framework, is expected to detect the 21 cm signal with high significance. I will present this framework and the simulations, and their potential for designing upcoming radio instruments such as HERA and the Square Kilometre Array (SKA).

  17. Intercomparison of radiation protection instrumentation in a pulsed neutron field

    CERN Document Server

    Caresana, M; Esposito, A; Ferrarini, M; Golnik, N; Hohmann, E; Leuschner, A; Luszik-Bhadra, M; Manessi, G; Mayer, S; Ott, K; Röhrich, J; Silari, M; Trompier, F; Volnhals, M; Wielunski, M

    2014-01-01

    In the framework of the EURADOS working group 11, an intercomparison of active neutron survey meters was performed in a pulsed neutron field (PNF). The aim of the exercise was to evaluate the performances of various neutron instruments, including commercially available rem-counters, personal dosemeters and instrument prototypes. The measurements took place at the cyclotron of the Helmholtz-Zentrum Berlin für Materialien und Energie GmbH. The cyclotron is routinely used for proton therapy of ocular tumours, but an experimental area is also available. For the therapy the machine accelerates protons to 68 MeV. The interaction of the proton beam with a thick tungsten target produces a neutron field with energy up to about 60 MeV. One interesting feature of the cyclotron is that the beam can be delivered in bursts, with the possibility to modify in a simple and flexible way the burst length and the ion current. Through this possibility one can obtain radiation bursts of variable duration and intensity. All instru...

  18. Design of improved detection instrumentation for the annulus gas system for wolsong 2

    International Nuclear Information System (INIS)

    Kim, Seog Nam; Koo, Jun Mo; Chang, Ik Ho; Jung, Ho Chang; Han, Sang Joon

    1996-01-01

    The improved and advanced Annulus Gas System (AGS) has been developed for Wolsong 2 to satisfy the requirements of the regulatory body. The Atomic Energy Control Board (AECB) required a shorter detection time following a small leak from a pressure tube and/or calandria tube. This paper describes licensing requirements, functional requirements and detail design description for the AGS. The Wolsong unit No. 1 AGS was designed to operate as a stagnant system normally requiring only pressure regulation and having provisions for purging. The improved AGS involves the adoption of gas recirculation in AGS, duplication of dew point indicators with additional instrumentation and sampling provisions to prompt operator action. The improved system operates in the recirculation mode with continuous dew point measurement for leak detection. An AGS with improved detection instrumentation is provided. 8 refs., 3 figs. (author)

  19. Active Radiation Level Measurement on New Laboratory Instrument for Evaluating the Antibacterial Activity of Radioisotope

    International Nuclear Information System (INIS)

    Joh, Eunha; Park, Jang Guen

    2014-01-01

    A disc method has been widely used to measure the antibacterial effect of chemical agents. However, it is difficult to measure the antibacterial effect of radioisotopes using a disc method. A disc method is a method for diffusing a drug by placing the drug containing disc on the medium. In this method, radioisotopes are diffused on the medium and it is difficult to measure the exact effect by radiation. Thus, new laboratory equipment needs to evaluate the antibacterial activity by the radioisotopes. In this study, we measured the radiation level of radioisotopes on a new laboratory instrument using a MCNP. A disc method has been widely used to measure the antibacterial effect of chemical agents. This method uses a drug diffusion system for the measurement of anti-bacterial antibiotics. To measure the antimicrobial activity of a radioisotope, a new type of laboratory instrument is necessary to prevent the drug from spreading. The radioisotopes are used to diagnose and treat cancer. However, studies for anti-biotical use have not progressed. The radiation of radioisotopes has the effect of killing bacteria. Before this study proceeds further, it is necessary to be able to measure the antimicrobial activity of the radioisotope easily in the laboratory. However, in this study, it was possible to measure the antimicrobial activity of the radioisotope in the laboratory using a new laboratory instrument. We intend to start evaluation studies of the antibacterial activity of specific radioisotopes. In addition, it will be possible to develop research to overcome diseases caused by bacteria in the future

  20. Active Radiation Level Measurement on New Laboratory Instrument for Evaluating the Antibacterial Activity of Radioisotope

    Energy Technology Data Exchange (ETDEWEB)

    Joh, Eunha; Park, Jang Guen [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    A disc method has been widely used to measure the antibacterial effect of chemical agents. However, it is difficult to measure the antibacterial effect of radioisotopes using a disc method. A disc method is a method for diffusing a drug by placing the drug containing disc on the medium. In this method, radioisotopes are diffused on the medium and it is difficult to measure the exact effect by radiation. Thus, new laboratory equipment needs to evaluate the antibacterial activity by the radioisotopes. In this study, we measured the radiation level of radioisotopes on a new laboratory instrument using a MCNP. A disc method has been widely used to measure the antibacterial effect of chemical agents. This method uses a drug diffusion system for the measurement of anti-bacterial antibiotics. To measure the antimicrobial activity of a radioisotope, a new type of laboratory instrument is necessary to prevent the drug from spreading. The radioisotopes are used to diagnose and treat cancer. However, studies for anti-biotical use have not progressed. The radiation of radioisotopes has the effect of killing bacteria. Before this study proceeds further, it is necessary to be able to measure the antimicrobial activity of the radioisotope easily in the laboratory. However, in this study, it was possible to measure the antimicrobial activity of the radioisotope in the laboratory using a new laboratory instrument. We intend to start evaluation studies of the antibacterial activity of specific radioisotopes. In addition, it will be possible to develop research to overcome diseases caused by bacteria in the future.

  1. Measurements of radiation exposure on commercial aircraft with the LIULIN-3M instrument

    International Nuclear Information System (INIS)

    Stassinopoulos, E.G.; Stauffer, C.A.; Dachev, T.P.; Tomov, B.T.; Dimitrov, P.G.; Brucker, G.J.

    1999-01-01

    The LIULIN-3M evolved from an international cooperative project by a group of Bulgarian, Russian, German, and American scientists. The radiometer is a low power, small size, light weight, and low cost instrument composed of a solid state detector (SSD) with supporting electronics that enable it to operate as a pulse height analyzer of energy deposited in the detector, and to obtain from these measurements the total dose or the dose rate produced by charged particles. The instrument has also been used as a low-LET radiation spectrometer for measuring biological doses of potential human exposures. A flash memory allows self-storage of data during flights and post flight retrieval. Results will be presented and discussed. (author)

  2. Global Observations of Aerosols and Clouds from Combined Lidar and Passive Instruments to Improve Radiation Budget and Climate Studies

    Science.gov (United States)

    Winker, David M.

    1999-01-01

    Current uncertainties in the effects of clouds and aerosols on the Earth radiation budget limit our understanding of the climate system and the potential for global climate change. Pathfinder Instruments for Cloud and Aerosol Spaceborne Observations - Climatologie Etendue des Nuages et des Aerosols (PICASSO-CENA) is a recently approved satellite mission within NASA's Earth System Science Pathfinder (ESSP) program which will address these uncertainties with a unique suite of active and passive instruments. The Lidar In-space Technology Experiment (LITE) demonstrated the potential benefits of space lidar for studies of clouds and aerosols. PICASSO-CENA builds on this experience with a payload consisting of a two-wavelength polarization-sensitive lidar, an oxygen A-band spectrometer (ABS), an imaging infrared radiometer (IIR), and a wide field camera (WFC). Data from these instruments will be used to measure the vertical distributions of aerosols and clouds in the atmosphere, as well as optical and physical properties of aerosols and clouds which influence the Earth radiation budget. PICASSO-CENA will be flown in formation with the PM satellite of the NASA Earth Observing System (EOS) to provide a comprehensive suite of coincident measurements of atmospheric state, aerosol and cloud optical properties, and radiative fluxes. The mission will address critical uncertainties iin the direct radiative forcing of aerosols and clouds as well as aerosol influences on cloud radiative properties and cloud-climate radiation feedbacks. PICASSO-CENA is planned for a three year mission, with a launch in early 2003. PICASSO-CENA is being developed within the framework of a collaboration between NASA and CNES.

  3. An investigation of medical radiation detection using CMOS image sensors in smartphones

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Han Gyu [Department of Senior Healthcare, Graduate School of Eulji University, Daejeon 301-746 (Korea, Republic of); Song, Jae-Jun [Department of Otorhinolaryngology-Head & Neck Surgery, Korea University, Guro Hospital,148, Gurodong-ro, Guro-gu, Seoul 152-703 (Korea, Republic of); Lee, Kwonhee [Graduate Program in Bio-medical Science, Korea University, 2511 Sejong-ro, Sejong City 339-770 (Korea, Republic of); Nam, Ki Chang [Department of Medical Engineering, College of Medicine, Dongguk University, 32 Dongguk-ro, Goyang-si, Gyeonggi-do 410-820 (Korea, Republic of); Hong, Seong Jong; Kim, Ho Chul [Department of Radiological Science, Eulji University, 553 Yangji-dong, Sujeong-gu, Seongnam-si, Gyeonggi-do 431-713 (Korea, Republic of)

    2016-07-01

    Medical radiation exposure to patients has increased with the development of diagnostic X-ray devices and multi-channel computed tomography (CT). Despite the fact that the low-dose CT technique can significantly reduce medical radiation exposure to patients, the increasing number of CT examinations has increased the total medical radiation exposure to patients. Therefore, medical radiation exposure to patients should be monitored to prevent cancers caused by diagnostic radiation. However, without using thermoluminescence or glass dosimeters, it is hardly measure doses received by patients during medical examinations accurately. Hence, it is necessary to develop radiation monitoring devices and algorithms that are reasonably priced and have superior radiation detection efficiencies. The aim of this study is to investigate the feasibility of medical dose measurement using complementary metal oxide semiconductor (CMOS) sensors in smartphone cameras with an algorithm to extract the X-ray interacted pixels. We characterized the responses of the CMOS sensors in a smartphone with respect to the X-rays generated by a general diagnostic X-ray system. The characteristics of the CMOS sensors in a smartphone camera, such as dose response linearity, dose rate dependence, energy dependence, angular dependence, and minimum detectable activity were evaluated. The high energy gamma-ray of 662 keV from Cs-137 can be detected using the smartphone camera. The smartphone cameras which employ the developed algorithm can detect medical radiations.

  4. An investigation of medical radiation detection using CMOS image sensors in smartphones

    International Nuclear Information System (INIS)

    Kang, Han Gyu; Song, Jae-Jun; Lee, Kwonhee; Nam, Ki Chang; Hong, Seong Jong; Kim, Ho Chul

    2016-01-01

    Medical radiation exposure to patients has increased with the development of diagnostic X-ray devices and multi-channel computed tomography (CT). Despite the fact that the low-dose CT technique can significantly reduce medical radiation exposure to patients, the increasing number of CT examinations has increased the total medical radiation exposure to patients. Therefore, medical radiation exposure to patients should be monitored to prevent cancers caused by diagnostic radiation. However, without using thermoluminescence or glass dosimeters, it is hardly measure doses received by patients during medical examinations accurately. Hence, it is necessary to develop radiation monitoring devices and algorithms that are reasonably priced and have superior radiation detection efficiencies. The aim of this study is to investigate the feasibility of medical dose measurement using complementary metal oxide semiconductor (CMOS) sensors in smartphone cameras with an algorithm to extract the X-ray interacted pixels. We characterized the responses of the CMOS sensors in a smartphone with respect to the X-rays generated by a general diagnostic X-ray system. The characteristics of the CMOS sensors in a smartphone camera, such as dose response linearity, dose rate dependence, energy dependence, angular dependence, and minimum detectable activity were evaluated. The high energy gamma-ray of 662 keV from Cs-137 can be detected using the smartphone camera. The smartphone cameras which employ the developed algorithm can detect medical radiations.

  5. Quality assurance in radiation processing

    International Nuclear Information System (INIS)

    Noriah Mod Ali

    2002-01-01

    The growth of the radiation processing industries in Malaysia has presented the SSDL-MINT a new set of parameter for the Quality Assurance (QA) programs. The large massive doses of radiation required for commercial application of sterilization, cross-linking etc needs measurement method outside the scope of familiar radiation detection instruments. This requires establishment of proper calibration procedure and selection of appropriate transfer system/technique to assure adequate traceability to an international radiation standard. The benefit of accurate in-plant dosimetry for the operator, approving authority and purchaser are balanced against the extra dosimetric efforts required for good QA is presented. (Author)

  6. Radiation Detection System for Prevention of Illicit Trafficking of Nuclear and Radioactive Materials

    International Nuclear Information System (INIS)

    Kwak, Sung Woo; Chang, Sung Soon; Yoo, Ho Sik

    2010-01-01

    Fixed radiation portal monitors (RPMs) deployed at border, seaport, airport and key traffic checkpoints have played an important role in preventing the illicit trafficking and transport of nuclear and radioactive materials. However, the RPM is usually large and heavy and can't easily be moved to different locations. These reasons motivate us to develop a mobile radiation detection system. The objective of this paper is to report our experience on developing the mobile radiation detection system for search and detection of nuclear and radioactive materials during road transport. Field tests to characterize the developed detection system were performed at various speeds and distances between the radioactive isotope (RI) transporting car and the measurement car. Results of measurements and detection limits of our system are described in this paper. The mobile radiation detection system developed should contribute to defending public's health and safety and the environment against nuclear and radiological terrorism by detecting nuclear or radioactive material hidden illegally in a vehicle

  7. Calibration of "Babyline" RP instruments

    CERN Multimedia

    2015-01-01

      If you have old RP instrumentation of the “Babyline” type, as shown in the photo, please contact the Radiation Protection Group (Joffrey Germa, 73171) to have the instrument checked and calibrated. Thank you. Radiation Protection Group

  8. Instrumentation and Controls Division annual progress report for period ending September 1, 1974. Non-LMFBR program

    International Nuclear Information System (INIS)

    Sadowski, G.S.

    1976-09-01

    Research projects are summarized under the following categories: (1) basic electronics development; (2) engineering support for research facilities; (3) pulse counting and analysis; (4) radiation detection and monitoring; (5) instrument development; (6) automatic control and data acquisition; (7) process systems and instrumentation development; (8) reactor instrumentation and controls; (9) fuel reprocessing and shipping; (10) standards laboratory; (11) instrumentation for reactor division experiments and test loops; (12) maintenance and service; (13) ecological science studies; and (14) administration and training

  9. Instrumentation and Controls Division annual progress report for period ending September 1, 1974. Non-LMFBR program

    Energy Technology Data Exchange (ETDEWEB)

    Sadowski, G.S. (comp.)

    1976-09-01

    Research projects are summarized under the following categories: (1) basic electronics development; (2) engineering support for research facilities; (3) pulse counting and analysis; (4) radiation detection and monitoring; (5) instrument development; (6) automatic control and data acquisition; (7) process systems and instrumentation development; (8) reactor instrumentation and controls; (9) fuel reprocessing and shipping; (10) standards laboratory; (11) instrumentation for reactor division experiments and test loops; (12) maintenance and service; (13) ecological science studies; and (14) administration and training. (WHK)

  10. Evaluating musical instruments

    International Nuclear Information System (INIS)

    Campbell, D. Murray

    2014-01-01

    Scientific measurements of sound generation and radiation by musical instruments are surprisingly hard to correlate with the subtle and complex judgments of instrumental quality made by expert musicians

  11. MDS G(N) fast differentiation between natural and artificial gamma radiation with a new class of mobile instruments

    International Nuclear Information System (INIS)

    Katzung, W.; Bottcher, J.

    2009-01-01

    A State-of-the-Art tool used for detecting and tracking artificial gamma radiation out of a helicopter or a vehicle is the MDS G(N) - Mobile Detection System. A highly sensitive scintillation detector detects a significant artificial gamma radiation on the ground even if the helicopter is travelling at high speed. The GPS-aided system visualizes the measured values on a moveable map displayed on the screen of a notebook every second. The colours of the continuously entered points do represent adjustable alarm thresholds. This way, location and intensity of an unknown radioactive source or a radioactive contamination can be determined very quickly. The NBR-technology (Natural Background Rejection) which is used here leads to expressive measurement results differentiating between artificial and natural gamma radiation. Additional He-3 detectors allow simultaneously the detection of neutrons. The NBR principle - developed by Thermo Scientific - stands out for its very short response times. Thus, artificial radiation can be detected reliably within seconds - even when the unit is operated by untrained staff. Unlike traditional analytic measuring techniques, the NBR method is able to detect artificial radiation sources hidden or strongly shielded gamma sources clearly from the natural background radiation. The measuring range from 1 nSv/h to 20 ?Sv/h and is extended to 1 Sv/h with a Geiger Mueller counting tube. The sensitivity amounts to max. 20000 cps (referred to 1 ?Sv/h for Cs-137). The NBR- technique is well-proven and tested for: tracking hidden radiation sources, even such ones with low activity or which are shielded, detection of artificial radiation portions in the range of the natural background, reliably measuring the ambient equivalent dose rate in the range of the natural background, fast detection of artificial radioactivity out of helicopters and vehicles.(author)

  12. EPR detection of foods preserved with ionizing radiation

    Science.gov (United States)

    Stachowicz, W.; Burlinska, G.; Michalik, J.

    1998-06-01

    The applicability of the epr technique for the detection of dried vegetables, mushrooms, some spices, flavour additives and some condiments preserved with ionizing radiation is discussed. The epr signals recorded after exposure to gamma rays and to beams of 10 MeV electrons from linac are stable, intense and specific enough as compared with those observed with nonirradiated samples and could be used for the detection of irradiation. However, stability of radiation induced epr signals produced in these foods depends on storage condition. No differences in shapes (spectral parameters) and intensities of the epr spectra recorded with samples exposed to the same doses of gamma rays ( 60Co) and 10 MeV electrons were observed

  13. EPR detection of foods preserved with ionizing radiation

    International Nuclear Information System (INIS)

    Stachowicz, W.; Burlinska, G.; Michalik, J.

    1998-01-01

    The applicability of the epr technique for the detection of dried vegetables, mushrooms, some spices, flavour additives and some condiments preserved with ionizing radiation is discussed. The epr signals recorded after exposure to gamma rays and to the beams of 10 MeV electrons from linac are stable, intense and specific enough as compared with those observed with nonirradiated samples and could be used for the detection of irradiation. However, stability of radiation induced epr signals produced in these foods depends on storage condition. No differences in shapes (spectral parameters) and intensities of the epr spectra recorded with samples exposed to the same doses of gamma rays ( 60 Co) and 10 MeV electrons were observed

  14. EPR detection of foods preserved with ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Stachowicz, W.; Burlinska, G.; Michalik, J

    1998-06-01

    The applicability of the epr technique for the detection of dried vegetables, mushrooms, some spices, flavour additives and some condiments preserved with ionizing radiation is discussed. The epr signals recorded after exposure to gamma rays and to the beams of 10 MeV electrons from linac are stable, intense and specific enough as compared with those observed with nonirradiated samples and could be used for the detection of irradiation. However, stability of radiation induced epr signals produced in these foods depends on storage condition. No differences in shapes (spectral parameters) and intensities of the epr spectra recorded with samples exposed to the same doses of gamma rays ({sup 60}Co) and 10 MeV electrons were observed.

  15. Tropospheric Aerosol Radiative Forcing Observational eXperiment - University of Washington instrumented C-131A aircraft Data Set

    Data.gov (United States)

    National Aeronautics and Space Administration — TARFOX_UWC131A is the Tropospheric Aerosol Radiative Forcing Observational eXperiment (TARFOX) - University of Washington instrumented C-131A aircraft data set. The...

  16. Smart instrumentation development at Los Alamos

    International Nuclear Information System (INIS)

    Erkkila, B.

    1984-01-01

    For several years Los Alamos has incorporated microprocessors into instruments to expand the capability of portable survey type equipment. Beginning with portable pulse height analyzers, the developments have expanded to small dedicated instruments which handle the measurement and interpretation of various radiation fields. So far, instruments to measure gamma rays, neutrons, and beta particles have been produced. The computer capability built into these instruments provides significant computational power into the instruments. Capability unheard of a few years ago in small portable instruments is routine today. Large computer-based laboratory measurement systems which required much space and electrical power can now be incorporated in a portable hand-held instrument. The microprocessor developments at Los Alamos are now restricted to radiation monitoring equipment but can be expanded to chemical and biological applications as well. Applications for radiation monitoring equipment and others are discussed

  17. Validation of the quality of life-radiation therapy instrument (QOL-RTI) in patients receiving definitive radiation therapy for locally advanced prostate cancer

    International Nuclear Information System (INIS)

    Gwede, Clement; Friedland, Jay L.; Johnson, Darlene J.; Casey, Linda; Cantor, Alan; Sauder, Bonnie; Beres, Kathleen L.

    1996-01-01

    Purpose/Objective: The incidence of prostate cancer has tripled over the last 10 years, doubled over the last four years and continues to increase. A common method of treating prostate cancer is with external beam radiotherapy with or without hormones. Accurate and comprehensive documentation through prospective studies with long term follow-up is necessary to reduce the negative impact of treatment on a patient's quality of life. While it is increasingly recognized that radiation therapy treatment for prostate cancer may result in permanent alteration of the patient's quality of life, the extent and timing of this change in quality of life has not been adequately investigated in a comprehensive and prospective manner. Furthermore, there are limited instruments developed for use with patients undergoing definitive radiotherapy. The purpose of this paper is to report on the validation of the Quality of Life Radiation Therapy Instrument (QOL-RTI), a 24-item visual analogue general quality of life tool developed for use with patients receiving radiotherapy. Materials and Methods: Health related quality of life was assessed in a prospective study of 62 patients treated with either combined hormonal therapy (HT) plus external beam radiotherapy (EBRT) or EBRT alone for locally advanced prostate cancer. Quality life was measured prospectively before, during, and after radiation therapy. Results: The estimated reliability of the subscales was assessed with coefficient alpha which ranged from 0.57 to 0.68. Internal consistency was calculated using initial questionnaires for the entire sample, yielding a Cronbach's alpha of 0.82. Test-retest produced a correlation coefficient of 0.75 (p<0.0001) [n=60]. Construct validity was assessed by a repeated measures design to look for time effect, group effect, group and time interaction effect. We examined quality of life total scores, subscale total scores and performance status scores for patients who were treated with HT+ EBRT and

  18. Research in radiation monitoring survey instrumentation. Final report

    International Nuclear Information System (INIS)

    Blalock, T.V.; Kennedy, E.J.; Phillips, R.G.; Walker, E.W. Jr.

    1978-01-01

    Two low-power solid-state prototype readout units were developed, an LED display and a LCD display. This display output was in a bar-graph format, covering four-decades of information, with 10-segments per decade. The displays accept a frequency input, which is standardly available from several portable radiation-survey instruments. Both readout units will operate on two D-cell batteries (3.0 Volt), with a typical current drain requirement of 0.3 MA for the LED display and 30μA for the LCD display. A wide-range electrometer circuit was also developed. The circuit covers an input current range from 10 -13 A to 10 -8 A. The output signal is a pulse whose frequency is directly proportional to input current. The circuit requires no high-megohm resistors, and is autoranging. Several candidate input amplifiers were analyzed and evaluated for use with the electrometer circuit

  19. Standoff alpha radiation detection for hot cell imaging and crime scene investigation

    Science.gov (United States)

    Kerst, Thomas; Sand, Johan; Ihantola, Sakari; Peräjärvi, Kari; Nicholl, Adrian; Hrnecek, Erich; Toivonen, Harri; Toivonen, Juha

    2018-02-01

    This paper presents the remote detection of alpha contamination in a nuclear facility. Alpha-active material in a shielded nuclear radiation containment chamber has been localized by optical means. Furthermore, sources of radiation danger have been identified in a staged crime scene setting. For this purpose, an electron-multiplying charge-coupled device camera was used to capture photons generated by alpha-induced air scintillation (radioluminescence). The detected radioluminescence was superimposed with a regular photograph to reveal the origin of the light and thereby the alpha radioactive material. The experimental results show that standoff detection of alpha contamination is a viable tool in radiation threat detection. Furthermore, the radioluminescence spectrum in the air is spectrally analyzed. Possibilities of camera-based alpha threat detection under various background lighting conditions are discussed.

  20. Radioisotope tracer instrument and its application to the detection of the groundwater parameters

    International Nuclear Information System (INIS)

    Chen Jiansheng

    1988-01-01

    The application of radioisotope tracer technique and probe can result in the detection of groundwater flow direction, flow velocity and vertical currents in one single well. The tracer probe consists of the source injector and the components related with direction detection, location and velocity measurement. The nuclear detector employs a thermoluminescence detector (TLD) and a direct reading ionization chamber (IC) for the detection of flow direction and also employs a new method of photofluorography location for the determination of the probe's northern or southern position in the well, thereby greatly simplifying the design of the direction-detecting probe. The velocity measuring section includes ground receiving instruments and meters for conducting point or whole-borehole measurement. It is also possible to carry out interconnection tests and dispersion tests. With the applications to the ascertaining of the groundwater distribution in the karst region as well as the execution of the dispersion tests related with environmental protection and so on, it has been confirmed that the radioisotope tracer instrument has a broad scope of application and practicability. (author). 5 refs, 6 figs

  1. Waveshifters and Scintillators for Ionizing Radiation Detection

    International Nuclear Information System (INIS)

    Baumgaugh, B.; Bishop, J.; Karmgard, D.; Marchant, J.; McKenna, M.; Ruchti, R.; Vigneault, M.; Hernandez, L.; Hurlbut, C.

    2007-01-01

    Scintillation and waveshifter materials have been developed for the detection of ionizing radiation in an STTR program between Ludlum Measurements, Inc. and the University of Notre Dame. Several new waveshifter materials have been developed which are comparable in efficiency and faster in fluorescence decay than the standard material Y11 (K27) used in particle physics for several decades. Additionally, new scintillation materials useful for fiber tracking have been developed which have been compared to 3HF. Lastly, work was done on developing liquid scintillators and paint-on scintillators and waveshifters for high radiation environments

  2. Detection of organic compound signatures in infra-red, limb emission spectra observed by the MIPAS-B2 balloon instrument

    Directory of Open Access Journals (Sweden)

    J. J. Remedios

    2007-01-01

    Full Text Available Organic compounds play a central role in troposphere chemistry and increasingly are a viable target for remote sensing observations. In this paper, infra-red spectral features of three organic compounds are investigated in thermal emission spectra recorded on a flight on 8 May 1998 near Aire sur l'Adour by a balloon-borne instrument, MIPAS-B2, operating at high spectral resolution. It is demonstrated, for the first time, that PAN and acetone can be detected in infra-red remote sensing spectra of the upper troposphere; detection results are presented at tangent altitudes of 10.4 km and 7.5 km (not acetone. In addition, the results provide the first observation of spectral features of formic acid in thermal emission, as opposed to solar occultation, and confirm that concentrations of this gas are measurable in the mid-latitude upper troposphere, given accurate spectroscopic data. For PAN, two bands are observed centred at 794 cm−1 and 1163 cm−1. For acetone and formic acid, one band has been detected for each so far with band centres at 1218 cm−1 and 1105 cm−1 respectively. Mixing ratios inferred at 10.4 km tangent altitude are 180 pptv and 530 pptv for PAN and acetone respectively, and 200 pptv for formic acid with HITRAN 2000 spectroscopy. Accuracies are on the order of 15 to 40%. The detection technique applied here is verified by examining weak but known signatures of CFC-12 and HCFC-22 in the same spectral regions as those of the organic compounds, with results confirming the quality of both the instrument and the radiative transfer model. The results suggest the possibility of global sensing of the organic compounds studied here which would be a major step forward in verifying and interpreting global tropospheric model calculations.

  3. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2000-01-01

    SCK-CEN's research and development programme on instrumentation aims at evaluating the potentials of new instrumentation technologies under the severe constraints of a nuclear application. It focuses on the tolerance of sensors to high radiation doses, including optical fibre sensors, and on the related intelligent data processing needed to cope with the nuclear constraints. Main achievements in these domains in 1999 are summarised

  4. Maintenance of nuclear instruments

    International Nuclear Information System (INIS)

    Oliveira Rebelo, A.M. de; Santos, C.J.F. dos; Jesus, E.F.O. de; Silva, L.E.M.C.; Borges, J.C.

    1988-01-01

    A program to design and repairing of nuclear instruments for teaching and research was founded in the UFRJ to find solutions for technical support problem - The GEMD-RADIACOES. This group has assisted to several groups of the University in recuperation and conservation of devices like: Linear scanner, Cromatograph and system of radiation detection in general. Recuperation of these devices had required a study of theirs operations modes, to make it possible the setting up of a similar system. Recuperation also involves operation tests, calibration and technical for users, orienting them to get the best performance. (Author) [pt

  5. Radiation anomaly detection algorithms for field-acquired gamma energy spectra

    Science.gov (United States)

    Mukhopadhyay, Sanjoy; Maurer, Richard; Wolff, Ron; Guss, Paul; Mitchell, Stephen

    2015-08-01

    The Remote Sensing Laboratory (RSL) is developing a tactical, networked radiation detection system that will be agile, reconfigurable, and capable of rapid threat assessment with high degree of fidelity and certainty. Our design is driven by the needs of users such as law enforcement personnel who must make decisions by evaluating threat signatures in urban settings. The most efficient tool available to identify the nature of the threat object is real-time gamma spectroscopic analysis, as it is fast and has a very low probability of producing false positive alarm conditions. Urban radiological searches are inherently challenged by the rapid and large spatial variation of background gamma radiation, the presence of benign radioactive materials in terms of the normally occurring radioactive materials (NORM), and shielded and/or masked threat sources. Multiple spectral anomaly detection algorithms have been developed by national laboratories and commercial vendors. For example, the Gamma Detector Response and Analysis Software (GADRAS) a one-dimensional deterministic radiation transport software capable of calculating gamma ray spectra using physics-based detector response functions was developed at Sandia National Laboratories. The nuisance-rejection spectral comparison ratio anomaly detection algorithm (or NSCRAD), developed at Pacific Northwest National Laboratory, uses spectral comparison ratios to detect deviation from benign medical and NORM radiation source and can work in spite of strong presence of NORM and or medical sources. RSL has developed its own wavelet-based gamma energy spectral anomaly detection algorithm called WAVRAD. Test results and relative merits of these different algorithms will be discussed and demonstrated.

  6. Radiological Instrumentation Assessment for King County Wastewater Treatment Division

    International Nuclear Information System (INIS)

    Strom, Daniel J.; McConn, Ronald J.; Brodzinski, Ronald L.

    2005-01-01

    The King County Wastewater Treatment Division (WTD) have concern about the aftermath of a radiological dispersion event (RDE) leading to the introduction of significant quantities of radioactive material into its combined sanitary and storm sewer system. Radioactive material could come from the use of a radiological dispersion device (RDD). RDDs include 'dirty bombs' that are not nuclear detonations but are explosives designed to spread radioactive material. Radioactive material also could come from deliberate introduction or dispersion of radioactive material into the environment, including waterways and water supply systems. Volume 2 of PNNL-15163 assesses the radiological instrumentation needs for detection of radiological or nuclear terrorism, in support of decisions to treat contaminated wastewater or to bypass the West Point Treatment Plant (WPTP), and in support of radiation protection of the workforce, the public, and the infrastructure of the WPTP. Fixed radiation detection instrumentation should be deployed in a defense-in-depth system that provides (1) early warning of significant radioactive material on the way to the WPTP, including identification of the radionuclide(s) and estimates of the soluble concentrations, with a floating detector located in the wet well at the Interbay Pump Station and telemetered via the internet to all authorized locations; (2) monitoring at strategic locations within the plant, including (2a) the pipe beyond the hydraulic ram in the bar screen room; (2b) above the collection funnels in the fine grit facility; (2c) in the sampling tank in the raw sewage pump room; and (2d) downstream of the concentration facilities that produce 6% blended and concentrated biosolids. Engineering challenges exist for these applications. It is necessary to deploy both ultra-sensitive detectors to provide early warning and identification and detectors capable of functioning in high-dose rate environments that are likely under some scenarios

  7. Selected nondestructive assay instrumentation for an international safeguards system at uranium enrichment plants

    International Nuclear Information System (INIS)

    Tape, J.W.; Baker, M.P.; Strittmatter, R.; Jain, M.; Evans, M.L.

    1979-01-01

    A selected set of nondestructive assay instruments for an international safeguards system at uranium enrichment plants is currently under development. These instruments are of three types: in-line enrichment meters for feed, product, and tails streams; area radiation monitors for direct detection of high-enriched uranium production, and an enrichment meter for spent alumina trap material. The current status of the development of each of these instruments is discussed, with supporting data, as well as the role each would play in a total international safeguards system. 5 figures

  8. Advanced Space Radiation Detector Technology Development

    Science.gov (United States)

    Wrbanek, John D.; Wrbanek, Susan Y.; Fralick, Gustave C.

    2013-01-01

    The advanced space radiation detector development team at the NASA Glenn Research Center (GRC) has the goal of developing unique, more compact radiation detectors that provide improved real-time data on space radiation. The team has performed studies of different detector designs using a variety of combinations of solid-state detectors, which allow higher sensitivity to radiation in a smaller package and operate at lower voltage than traditional detectors. Integration of multiple solid-state detectors will result in an improved detector system in comparison to existing state-of-the-art instruments for the detection and monitoring of the space radiation field for deep space and aerospace applications.

  9. Plasmonically enhanced thermomechanical detection of infrared radiation.

    Science.gov (United States)

    Yi, Fei; Zhu, Hai; Reed, Jason C; Cubukcu, Ertugrul

    2013-04-10

    Nanoplasmonics has been an attractive area of research due to its ability to localize and manipulate freely propagating radiation on the nanometer scale for strong light-matter interactions. Meanwhile, nanomechanics has set records in the sensing of mass, force, and displacement. In this work, we report efficient coupling between infrared radiation and nanomechanical resonators through nanoantenna enhanced thermoplasmonic effects. Using efficient conversion of electromagnetic energy to mechanical energy in this plasmo-thermomechanical platform with a nanoslot plasmonic absorber integrated directly on a nanobeam mechanical resonator, we demonstrate room-temperature detection of nanowatt level power fluctuations in infrared radiation. We expect our approach, which combines nanoplasmonics with nanomechanical resonators, to lead to optically controlled nanomechanical systems enabling unprecedented functionality in biomolecular and toxic gas sensing and on-chip mass spectroscopy.

  10. Instrument for detecting gas bubbles in sodium filled pipework

    Energy Technology Data Exchange (ETDEWEB)

    Stapleton, D

    1973-08-01

    An instrument employing an electromagnetic sensor is described. Gas bubbles down to 0.5 mm diameter can be detected in sodium filled pipework of 1 in. nominal bore at temperatures up to 400 deg C. Installation of the sensing head involves no break in the integrity of the pipework. Facilities to enable bubble size discrimination, bubble counting and timing pulse generation are provided in the signal processing unit. Initial operating experience has been gained on a sodium loop used for gas entrainment studies. (auth)

  11. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2000-07-01

    SCK-CEN's research and development programme on instrumentation aims at evaluating the potentials of new instrumentation technologies under the severe constraints of a nuclear application. It focuses on the tolerance of sensors to high radiation doses, including optical fibre sensors, and on the related intelligent data processing needed to cope with the nuclear constraints. Main achievements in these domains in 1999 are summarised.

  12. Improvement of equipment needed for the detection and characterization of nuclear material and radioactive samples at borders

    International Nuclear Information System (INIS)

    Arlt, R.; Kovar, A.; Swoboda, M.; Beck, P.; Duftschmid, K.E.; Lewis, W.

    2001-01-01

    Nuclear radiation measurement instruments and devices for the detection and characterisation of nuclear material and radioactive isotopes at borders play a decisive role in the set of technical measures needed to deal with the problem of illicit trafficking. Therefore the availability of a range of devices with adequate performance at affordable prices is essential. The needed equipment can be classified into the following categories: Detection equipment (border monitors and radiation pagers); Hand held devices for neutron/gamma source search and in-field characterisation of radiation sources by customs inspectors; NDA (non-destructive assay) instruments for in-depth investigation of a seized item by experts either in the field or under laboratory conditions. Instruments and techniques, which use destructive assay methods, are not considered in this paper. The most recent overview on the performance of such instruments is given in the Final Report of ITRAP (Illicit Trafficking Radiation Detection Assessment Program). According to the findings of ITRAP, although in all above mentioned categories equipment is commercially available, deficiencies and shortcomings were identified. In this paper we describe our effort in addressing some of the most essential equipment problems, identified in ITRAP - the sensitivity of border monitors with respect to the detection of nuclear material and the performance and usability of hand held and portable devices needed for in-field characterisation of seized items by customs inspectors

  13. Instrumentation device at the outside of reactor and method of using the same

    International Nuclear Information System (INIS)

    Ichige, Masayuki.

    1997-01-01

    The present invention provides instrumentation device at the outside of a reactor capable of measuring conditions of inside of a reactor, such as the power of the reactor, distribution of voids or water level while considering hysteresis of neutrons or γ-rays from the inside to the outside of the reactor. Namely, a plurality of radiation detectors are disposed being elongated in vertical direction at a predetermined distance on the outer circumference of a reactor pressure vessel. The detectors detect intensity of radiation rays and the detection time at a plurality of positions of the outer side of the reactor. An amplifier amplifies the detected signals. A signal processing device determines the positions and the time of the emitted radiation rays based on the amplified detected signals. An analysis device analyzes spacial distribution and time distribution of the energy and the intensity of the radiation rays (neutron or γ-rays) based on the signals of predetermined radiation rays at the outer side of the reactor. Then, spacial and time variation components and the power distribution, water level, change of the water level, void distribution are calculated while considering decay of the radiation rays based on the distribution of material densities of incore structures. (I.S.)

  14. Delay-Line Three-Dimensional Position Sensitive Radiation Detection

    Science.gov (United States)

    Jeong, Manhee

    High-resistivity silicon(Si) in large volumes and with good charge carrier transport properties has been produced and achieved success as a radiation detector material over the past few years due to its relatively low cost as well as the availability of well-established processing technologies. One application of that technology is in the fabrication of various position-sensing topologies from which the incident radiation's direction can be determined. We have succeeded in developing the modeling tools for investigating different position-sensing schemes and used those tools to examine both amplitude-based and time-based methods, an assessment that indicates that fine position-sensing can be achieved with simpler readout designs than are conventionally deployed. This realization can make ubiquitous and inexpensive deployment of special nuclear materials (SNM) detecting technology becomes more feasible because if one can deploy position-sensitive semiconductor detectors with only one or two contacts per side. For this purpose, we have described the delay-line radiation detector and its optimized fabrication. The semiconductor physics were simulated, the results from which guided the fabrication of the guard ring structure and the detector electrode, both of which included metal-field-plates. The measured improvement in the leakage current was confirmed with the fabricated devices, and the structures successfully suppressed soft-breakdown. We also demonstrated that fabricating an asymmetric strip-line structure successfully minimizing the pulse shaping and increases the distance through which one can propagate the information of the deposited charge distribution. With fabricated delay-line detectors we can acquire alpha spectra (Am-241) and gamma spectra (Ba-133, Co-57 and Cd-109). The delay-line detectors can therefore be used to extract the charge information from both ion and gamma-ray interactions. Furthermore, standard charge-sensitive circuits yield high SNR

  15. Laboratory for Calibration of Gamma Radiation Measurement Instruments (LabCal) of Institute of Chemical, Biological, Radiological and Nuclear Defense (IDQBRN) from Brazilian Army Technology Center (CTEx)

    International Nuclear Information System (INIS)

    Amorim, Aneuri de; Balthar, Mario Cesar V.; Santos, Avelino; Vilela, Paulo Ricardo T. de; Oliveira, Luciano Santa Rita; Penha, Paulo Eduardo C. de Oliveira; Gonzaga, Roberto Neves; Andrade, Edson Ramos de; Oliveira, Celio Jorge Vasques de; Fagundes, Luiz Cesar S.

    2016-01-01

    This paper describes the calibration laboratory deployment steps (LABCAL) gamma ionizing radiation measuring instruments in the Army Technology Center, CTEx. Initially the calibration of radiation monitors will be held in the dosimetric quantity air kerma and operational quantity ambient dose equivalent H*(d). The LABCAL / CTEx has not yet authorized by CASEC / CNEN. This laboratory aims to calibrate the ionizing radiation instruments used by the Brazilian Army. (author)

  16. Radiation protection instruments based on tissue equivalent proportional counters: Part II of an international intercomparison

    International Nuclear Information System (INIS)

    Alberts, W.G.; Dietz, E.; Guldbakke, S.; Kluge, H.; Schumacher, H.

    1988-04-01

    This report describes the irradiation conditions and procedures of Part II of an international intercomparison of tissue-equivalent proportional counters used for radiation protection measurements. The irradiations took place in monoenergetic reference neutron fields produced by the research reactor and accelerator facilities of the PTB Braunschweig in the range from thermal neutrons to 14.8 MeV. In addition measurements were performed in 60 Co and D 2 O-moderated 252 Cf radiation fields. Prototype instruments from 7 European groups were investigated. The results of the measurements are summarized and compared with the reference data of the irradiations. (orig.) [de

  17. Quench Detection and Instrumentation for the Tokamak Physics Experiment magnets

    International Nuclear Information System (INIS)

    Chaplin, M.R.; Hassenzahl, W.V.; Schultz, J.H.

    1993-01-01

    The design of the Local Instrumentation ampersand Control (I ampersand C) System for the Tokamak Physics Experiment (TPX) superconducting PF ampersand TF magnets is presented. The local I ampersand C system monitors the status of the magnet systems and initiates the proper control sequences to protect the magnets from any foreseeable fault. Local I ampersand C also stores magnet-system data for analysis and archiving. Quench Detection for the TPX magnets must use a minimum of two independent sensing methods and is allowed a detection time of one second. Proposed detection methods include the measurement of; (1) normal-zone resistive voltage, (2) cooling-path helium flow, (3) local temperature in the winding pack, (4) local pressure in the winding pack. Fiber-optic based isolation systems are used to remove high common-mode magnet voltages and eliminate ground loops. The data acquisition and fault-detection systems are computer based. The design of the local I ampersand C system incorporates redundant, fault-tolerant, and/or fail-safe features at all component levels. As part of a quench detection R ampersand D plan, a Quench Detection Model Coil has been proposed to test all detection methods. Initial cost estimates and schedule for the local I ampersand C system are presented

  18. A summary of the performance of exposure rate and dose rate instruments contained in instrument evaluation reports NRPB-IE1 to NRPB-IE13

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1979-06-01

    The various radiations encountered in radiological protection cover a wide range of energies and radiation measurements have to be carried out under an equally broad spectrum of environmental conditions. This report is one of a series intended to give information on the performance characteristics of radiological protection instruments, to assist in the selection of appropriate instruments for a given purpose, to interpret the results obtained with such instruments, and, in particular, to know the likely sources and magnitude of errors that might be associated with measurements in the field. The radiation, electrical and environmental characteristics of radiation protection instruments are considered together with those aspects of the construction which make an instrument convenient for routine use. To provide consistent criteria for instrument performance, the range of tests performed on any particular class of instrument, the test methods and the criteria of acceptable performance are based broadly on the appropriate Recommendations of the International Electrotechnical Commission. The radiations in the tests are, in general, selected from the range of reference radiations for instrument calibration being drawn up by the International Standards Organisation. Normally, each report deals with the capabilities and limitations of one model of instrument and no direct comparison with other instruments intended for similar purposes is made, since the significance of particular performance characteristics largely depends on the radiations and environmental conditions in which the instrument is to be used. The results quoted here have all been obtained from tests on instruments in routine production, with the appropriate measurements being made by the NRPB. This report provides a concise summary of measurements of the more important performance characteristics of radiation protection dose rate or exposure rate survey instruments which have been assessed by NRPB as part

  19. Instrumentation for Nuclear Applications

    International Nuclear Information System (INIS)

    1998-01-01

    The objective of this project was to develop and coordinate nuclear instrumentation standards with resulting economies for the nuclear and radiation fields. There was particular emphasis on coordination and management of the Nuclear Instrument Module (NIM) System, U.S. activity involving the CAMAC international standard dataway system, the FASTBUS modular high-speed data acquisition and control system and processing and management of national nuclear instrumentation and detector standards, as well as a modest amount of assistance and consultation services to the Pollutant Characterization and Safety Research Division of the Office of Health and Environmental Research. The principal accomplishments were the development and maintenance of the NIM instrumentation system that is the predominant instrumentation system in the nuclear and radiation fields worldwide, the CAMAC digital interface system in coordination with the ESONE Committee of European Laboratories, the FASTBUS high-speed system and numerous national and international nuclear instrumentation standards

  20. Analysis of the failures and corrective actions for the LHC cryogenics radiation tolerant electronics and its field instruments

    Energy Technology Data Exchange (ETDEWEB)

    Balle, Christoph; Casas, Juan; Vauthier, Nicolas [CERN, TE Department, 1211 Geneva (Switzerland)

    2014-01-29

    The LHC cryogenic system radiation tolerant electronics and their associated field instruments have been in nominal conditions since before the commissioning of the first LHC beams in September 2008. This system is made of about 15’000 field instruments (thermometers, pressure sensors, liquid helium level gauges, electrical heaters and position switches), 7’500 electronic cards and 853 electronic crates. Since mid-2008 a software tool has been deployed, this allows an operator to report a problem and then lists the corrective actions. The tool is a great help in detecting recurrent problems that may be tackled by a hardware or software consolidation. The corrective actions range from simple resets, exchange of defective equipment, repair of electrical connectors, etc. However a recurrent problem that heals by itself is present on some channels. This type of fault is extremely difficult to diagnose and it appears as a temporary opening of an electrical circuit; its duration can range from a few minutes to several months. This paper presents the main type of problems encountered during the last four years, their evolution over time, the various hardware or software consolidations that have resulted and whether they have had an impact in the availability of the LHC beam.

  1. Optimised mounting conditions for poly (ether sulfone) in radiation detection.

    Science.gov (United States)

    Nakamura, Hidehito; Shirakawa, Yoshiyuki; Sato, Nobuhiro; Yamada, Tatsuya; Kitamura, Hisashi; Takahashi, Sentaro

    2014-09-01

    Poly (ether sulfone) (PES) is a candidate for use as a scintillation material in radiation detection. Its characteristics, such as its emission spectrum and its effective refractive index (based on the emission spectrum), directly affect the propagation of light generated to external photodetectors. It is also important to examine the presence of background radiation sources in manufactured PES. Here, we optimise the optical coupling and surface treatment of the PES, and characterise its background. Optical grease was used to enhance the optical coupling between the PES and the photodetector; absorption by the grease of short-wavelength light emitted from PES was negligible. Diffuse reflection induced by surface roughening increased the light yield for PES, despite the high effective refractive index. Background radiation derived from the PES sample and its impurities was negligible above the ambient, natural level. Overall, these results serve to optimise the mounting conditions for PES in radiation detection. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Atmospheric Sounder Spectrometer for Infrared Spectral Technology (ASSIST) Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Flynn, Connor J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States). Atmospheric Radiation Measurement (ARM) Program

    2016-03-01

    The Atmospheric Sounder Spectrometer for Infrared Spectral Technology (ASSIST) measures the absolute infrared (IR) spectral radiance (watts per square meter per steradian per wavenumber) of the sky directly above the instrument. More information about the instrument can be found through the manufacturer’s website. The spectral measurement range of the instrument is 3300 to 520 wavenumbers (cm-1) or 3-19.2 microns for the normal-range instruments and 3300 to 400 cm-1 or 3-25 microns, for the extended-range polar instruments. Spectral resolution is 1.0 cm-1. Instrument field-of-view is 1.3 degrees. Calibrated sky radiance spectra are produced on cycle of about 141 seconds with a group of 6 radiance spectra zenith having dwell times of about 14 seconds each interspersed with 55 seconds of calibration and mirror motion. The ASSIST data is comparable to the Atmospheric Emitted Radiance Interferometer (AERI) data and can be used for 1) evaluating line-by-line radiative transport codes, 2) detecting/quantifying cloud effects on ground-based measurements of infrared spectral radiance (and hence is valuable for cloud property retrievals), and 3) calculating vertical atmospheric profiles of temperature and water vapor and the detection of trace gases.

  3. Additive Manufacturing Materials Study for Gaseous Radiation Detection

    Energy Technology Data Exchange (ETDEWEB)

    Steer, C.A.; Durose, A.; Boakes, J. [AWE Aldermaston, Reading, Berkshire, RG7 4PR (United Kingdom)

    2015-07-01

    Additive manufacturing (AM) techniques may lead to improvements in many areas of radiation detector construction; notably the rapid manufacturing time allows for a reduced time between prototype iterations. The additive nature of the technique results in a granular microstructure which may be permeable to ingress by atmospheric gases and make it unsuitable for gaseous radiation detector development. In this study we consider the application of AM to the construction of enclosures and frames for wire-based gaseous radiation tracking detectors. We have focussed on oxygen impurity ingress as a measure of the permeability of the enclosure, and the gas charging and discharging curves of several simplistic enclosure shapes are reported. A prototype wire-frame is also presented to examine structural strength and positional accuracy of an AM produced frame. We lastly discuss the implications of this study for AM based radiation detection technology as a diagnostic tool for incident response scenarios, such as the interrogation of a suspect radiation-emitting package. (authors)

  4. Additive Manufacturing Materials Study for Gaseous Radiation Detection

    International Nuclear Information System (INIS)

    Steer, C.A.; Durose, A.; Boakes, J.

    2015-01-01

    Additive manufacturing (AM) techniques may lead to improvements in many areas of radiation detector construction; notably the rapid manufacturing time allows for a reduced time between prototype iterations. The additive nature of the technique results in a granular microstructure which may be permeable to ingress by atmospheric gases and make it unsuitable for gaseous radiation detector development. In this study we consider the application of AM to the construction of enclosures and frames for wire-based gaseous radiation tracking detectors. We have focussed on oxygen impurity ingress as a measure of the permeability of the enclosure, and the gas charging and discharging curves of several simplistic enclosure shapes are reported. A prototype wire-frame is also presented to examine structural strength and positional accuracy of an AM produced frame. We lastly discuss the implications of this study for AM based radiation detection technology as a diagnostic tool for incident response scenarios, such as the interrogation of a suspect radiation-emitting package. (authors)

  5. Development of a novel gamma probe for detecting radiation direction

    Science.gov (United States)

    Pani, R.; Pellegrini, R.; Cinti, M. N.; Longo, M.; Donnarumma, R.; D'Alessio, A.; Borrazzo, C.; Pergola, A.; Ridolfi, S.; De Vincentis, G.

    2016-01-01

    Spatial localization of radioactive sources is currently a main issue interesting different fields, including nuclear industry, homeland security as well as medical imaging. It is currently achieved using different systems, but the development of technologies for detecting and characterizing radiation is becoming important especially in medical imaging. In this latter field, radiation detection probes have long been used to guide surgery, thanks to their ability to localize and quantify radiopharmaceutical uptake even deep in tissue. Radiolabelled colloid is injected into, or near to, the tumor and the surgeon uses a hand-held radiation detector, the gamma probe, to identify lymph nodes with radiopharmaceutical uptkake. The present work refers to a novel scintigraphic goniometric probe to identify gamma radiation and its direction. The probe incorporates several scintillation crystals joined together in a particular configuration to provide data related to the position of a gamma source. The main technical characteristics of the gamma locator prototype, i.e. sensitivity, spatial resolution and detection efficiency, are investigated. Moreover, the development of a specific procedure applied to the images permits to retrieve the source position with high precision with respect to the currently used gamma probes. The presented device shows a high sensitivity and efficiency to identify gamma radiation taking a short time (from 30 to 60 s). Even though it was designed for applications in radio-guided surgery, it could be used for other purposes, as for example homeland security.

  6. Development of a novel gamma probe for detecting radiation direction

    International Nuclear Information System (INIS)

    Pani, R.; Pellegrini, R.; Cinti, M.N.; Longo, M.; Donnarumma, R.; Borrazzo, C.; D'Alessio, A.; Pergola, A.; Ridolfi, S.; Vincentis, G. De

    2016-01-01

    Spatial localization of radioactive sources is currently a main issue interesting different fields, including nuclear industry, homeland security as well as medical imaging. It is currently achieved using different systems, but the development of technologies for detecting and characterizing radiation is becoming important especially in medical imaging. In this latter field, radiation detection probes have long been used to guide surgery, thanks to their ability to localize and quantify radiopharmaceutical uptake even deep in tissue. Radiolabelled colloid is injected into, or near to, the tumor and the surgeon uses a hand-held radiation detector, the gamma probe, to identify lymph nodes with radiopharmaceutical uptkake. The present work refers to a novel scintigraphic goniometric probe to identify gamma radiation and its direction. The probe incorporates several scintillation crystals joined together in a particular configuration to provide data related to the position of a gamma source. The main technical characteristics of the gamma locator prototype, i.e. sensitivity, spatial resolution and detection efficiency, are investigated. Moreover, the development of a specific procedure applied to the images permits to retrieve the source position with high precision with respect to the currently used gamma probes. The presented device shows a high sensitivity and efficiency to identify gamma radiation taking a short time (from 30 to 60 s). Even though it was designed for applications in radio-guided surgery, it could be used for other purposes, as for example homeland security

  7. Radiation Detection System for Prevention of Radiological and Nuclear Terrorism

    International Nuclear Information System (INIS)

    Kwak, Sung-Woo; Yoo, Ho-Sik; Jang, Sung-Sun; Kim, Jae-Kwang; Kim, Jung-Soo

    2007-01-01

    After the September 11 terrorist attack, the threat of a potential for a radiological or nuclear terrorist attack became more apparent. The threats relating to radiological or nuclear materials include a Radiological Dispersion Device (RDD), an Improved Nuclear Device (IND) or a State Nuclear Device (such as a Soviet manufactured suitcase nuclear weapon). For more effective countermeasures against the disaster, multilayer protection concept - prevention of smuggling of radioactive or nuclear material into our country through seaports or airports, detection and prevention of the threat materials in transit on a road, and prevention of their entry into a target building - is recommended. Due to different surrounding circumstances of where detection system is deployed, different types of radiation detection systems are required. There have been no studies on characteristics of detection equipment required under Korean specific conditions. This paper provides information on technical requirements of radiation detection system to achieve multi-layer countermeasures for the purpose of protecting the public and environment against radiological and nuclear terrorism

  8. Radioisotope instrument for measuring the position of interface of two liquid media with similar density

    International Nuclear Information System (INIS)

    Afanas'ev, V.N.; Kolyada, A.N.; Krejndlin, I.I.; Pakhunkov, Yu.I.

    1977-01-01

    A gamma level indicator is developed for automatic and continuous remote measuring the location of the interface of two liquids with close densities in closed and open containers. The density of the upper (light) medium is 1.0-1.2 g/cm 3 . The instrument incorporates a transmitter-receiver unit, a relay regulator, a power amplifier and a secondary instrument. The operating principle of the level indicator is based on the detection of gamma-radiation scattered by a controlled medium; the alternations in gamma radiation flux serve to automatically set the transmitter-receiver unit on the interface of two media. The specially developed small transmitter-receiver with an Am 241 gamma radiation source is very sensible to little medium density changes and stable against perturbing factor action. The level indicator developed may be used to measure and regulate the level of liquid contacting with an air (gas) medium. The specifications of the instrument are presented

  9. Evaluation of a Kalman filter based power pressurizer instrument failure detection system implemented on a nuclear power plant training simulator

    International Nuclear Information System (INIS)

    Seegmiller, D.S.

    1984-01-01

    The usefulness of a nuclear power plant training simulator for developing and testing modern estimation and control applications for nuclear power plants is demonstrated. A Kalman filter based instrument failure detection technique for a pressurized water reactor pressurizer is implemented on the Department of Energy N Reactor Training Simulator. This real-time failure detection method computes the first two moments (mean and variance) of each element of a normalized filter innovations vector. Failed pressurizer instrumentation can be detected by comparing these moments to the known statistical properties of the steady state, linear Kalman fitler innovations sequence. The capabilities of the detection system are evaluated using simulated plant transients and instrument failures

  10. Piezoelectric Materials Under Natural and Man-Made Radiation: The Potential for Direct Radiation Detection

    Science.gov (United States)

    Wart, Megan; Simpson, Evan; Flaska, Marek

    2018-01-01

    Radiation detection systems used for monitoring long term waste storage need to be compact, rugged, and have low or no power requirements. By using piezoelectric materials it may be possible to create a reliable self-powered radiation detection system. To determine the feasibility of this approach, the electrical signal response of the piezoelectric materials to radiation must be characterized. To do so, an experimental geometry has been designed and a neutron source has been chosen as described in this paper, which will be used to irradiate a uranium foil for producing fission fragments. These future experiments will be aimed at finding the threshold of exposure of lead zirconate titanate (PZT) plates needed to produce and electrical signal. Based on the proposed experimental geometry the thermal neutron beam-line at the Breazeale Reactor at The Pennsylvania State University will be used as the neutron source. The uranium foil and neutron source will be able to supply a maximum flux of 1.5e5 fission fragments/second*cm2 to each of the PZT plates.

  11. Piezoelectric Materials Under Natural and Man-Made Radiation: The Potential for Direct Radiation Detection

    Directory of Open Access Journals (Sweden)

    Wart Megan

    2018-01-01

    Full Text Available Radiation detection systems used for monitoring long term waste storage need to be compact, rugged, and have low or no power requirements. By using piezoelectric materials it may be possible to create a reliable self-powered radiation detection system. To determine the feasibility of this approach, the electrical signal response of the piezoelectric materials to radiation must be characterized. To do so, an experimental geometry has been designed and a neutron source has been chosen as described in this paper, which will be used to irradiate a uranium foil for producing fission fragments. These future experiments will be aimed at finding the threshold of exposure of lead zirconate titanate (PZT plates needed to produce and electrical signal. Based on the proposed experimental geometry the thermal neutron beam-line at the Breazeale Reactor at The Pennsylvania State University will be used as the neutron source. The uranium foil and neutron source will be able to supply a maximum flux of 1.5e5 fission fragments/second*cm2 to each of the PZT plates.

  12. Radiation detection and situation management by distributed sensor networks

    International Nuclear Information System (INIS)

    Jan, Frigo; Mielke, Angela; Cai, D. Michael

    2009-01-01

    Detection of radioactive materials in an urban environment usually requires large, portal-monitor-style radiation detectors. However, this may not be a practical solution in many transport scenarios. Alternatively, a distributed sensor network (DSN) could complement portal-style detection of radiological materials through the implementation of arrays of low cost, small heterogeneous sensors with the ability to detect the presence of radioactive materials in a moving vehicle over a specific region. In this paper, we report on the use of a heterogeneous, wireless, distributed sensor network for traffic monitoring in a field demonstration. Through wireless communications, the energy spectra from different radiation detectors are combined to improve the detection confidence. In addition, the DSN exploits other sensor technologies and algorithms to provide additional information about the vehicle, such as its speed, location, class (e.g. car, truck), and license plate number. The sensors are in-situ and data is processed in real-time at each node. Relevant information from each node is sent to a base station computer which is used to assess the movement of radioactive materials

  13. Exploiting Novel Radiation-Induced Electromagnetic Material Changes for Remote Detection and Monitoring: Final Progress Report

    Science.gov (United States)

    2016-04-01

    Exploiting Novel Radiation -Induced Electromagnetic Material Changes for Remote Detection and Monitoring: Final Progress Report Distribution...assess the effects of ionizing radiation on at least three classes of electromagnetic materials. The proposed approach for radiation detection was...that was desired to be monitored remotely. Microwave or low millimeter wave electromagnetic radiation would be used to interrogate the device

  14. Detecting solar chameleons through radiation pressure

    CERN Document Server

    Baum, Sebastian

    2014-01-01

    Light scalar fields can drive accelerated expansion of the universe. Hence, scalars are obvious dark energy candidates. To make these models compatible with test of General Relativity in the solar system and fifth force searches on earth, one needs to screen them. One possibility is the chameleon mechanism, which renders an effective mass depending on the local energy density. If chameleons exist, they can be produced in the sun and detected on earth through their radiation pressure. We calculate the solar chameleon spectrum and the sensitivity of an experiment to be carried out at CAST, CERN, utilizing a radiation pressure sensor currently under development at INFN, Trieste. We show that such an experiment will be sensitive to a wide range of model parameters and signifies a pioneering effort searching for chameleons in unprobed paramterspace.

  15. A new nano-enhanced technology proposed to quantify intracellular detection of radiation-induced metabolic processes.

    Science.gov (United States)

    Malak, Henryk; Richmond, Robert; Dicello, J F

    2011-02-01

    A new approach to intracellular detection and imaging of metabolic processes and pathways is presented that uses surface plasmon resonance to enhance interactions between photon-absorbing metabolites and metal nanoparticles in contact with cells in vitro or in vivo. Photon absorption in the nanoparticles creates plasmon fields, enhancing intrinsic metabolite fluorescence, thereby increasing absorption and emission rates, creating new spectral emission bands, shortening fluorescence lifetimes, becoming more photo-stable and increasing fluorescent resonance energy transfer efficiency. Because the cells remain viable, it is proposed that the method may be used to interrogate cells prior to and after irradiation, with the potential for automated analyses of intracellular interactive pathways associated with radiation exposures at lower doses than existing technologies. The design and concepts of the instrument are presented along with data for unexposed cells.

  16. A dual-sided coded-aperture radiation detection system

    International Nuclear Information System (INIS)

    Penny, R.D.; Hood, W.E.; Polichar, R.M.; Cardone, F.H.; Chavez, L.G.; Grubbs, S.G.; Huntley, B.P.; Kuharski, R.A.; Shyffer, R.T.; Fabris, L.; Ziock, K.P.; Labov, S.E.; Nelson, K.

    2011-01-01

    We report the development of a large-area, mobile, coded-aperture radiation imaging system for localizing compact radioactive sources in three dimensions while rejecting distributed background. The 3D Stand-Off Radiation Detection System (SORDS-3D) has been tested at speeds up to 95 km/h and has detected and located sources in the millicurie range at distances of over 100 m. Radiation data are imaged to a geospatially mapped world grid with a nominal 1.25- to 2.5-m pixel pitch at distances out to 120 m on either side of the platform. Source elevation is also extracted. Imaged radiation alarms are superimposed on a side-facing video log that can be played back for direct localization of sources in buildings in urban environments. The system utilizes a 37-element array of 5x5x50 cm 3 cesium-iodide (sodium) detectors. Scintillation light is collected by a pair of photomultiplier tubes placed at either end of each detector, with the detectors achieving an energy resolution of 6.15% FWHM (662 keV) and a position resolution along their length of 5 cm FWHM. The imaging system generates a dual-sided two-dimensional image allowing users to efficiently survey a large area. Imaged radiation data and raw spectra are forwarded to the RadioNuclide Analysis Kit (RNAK), developed by our collaborators, for isotope ID. An intuitive real-time display aids users in performing searches. Detector calibration is dynamically maintained by monitoring the potassium-40 peak and digitally adjusting individual detector gains. We have recently realized improvements, both in isotope identification and in distinguishing compact sources from background, through the installation of optimal-filter reconstruction kernels.

  17. Replacement of the Idaho National Engineering Laboratory Health Physics Instrumentation Laboratory

    International Nuclear Information System (INIS)

    1995-05-01

    The DOE-Idaho Operations Office (DOE-ID) has prepared an environmental assessment (EA) on the replacement of the Idaho National Engineering Laboratory Health Physics Instrumentation Laboratory at the Idaho National Engineering Laboratory (INEL). The purpose of this project is to replace the existing Health Physics Instrumentation Laboratory (HPIL) with a new facility to provide a safe environment for maintaining and calibrating radiation detection instruments used at the Idaho National Engineering Laboratory. The existing HPIL facility provides portable health physics monitoring instrumentation and direct reading dosimetry procurement, maintenance and calibration of radiation detection instruments, and research and development support-services to the INEL and others. However, the existing facility was not originally designed for laboratory activities and does not provide an adequate, safe environment for calibration activities. The EA examined the potential environmental impacts of the proposed action and evaluated reasonable alternatives, including the no action alternative in accordance with the Council on Environmental Quality (CEQ) Regulations (40 CFR Parts 1500-1508). Based on the environmental analysis in the attached EA, the proposed action will not have a significant effect on the human environment within the meaning of the National Environmental Policy Act (NEPA) and 40 CFR Parts 1508.18 and 1508.27. The selected action (the proposed alternative) is composed of the following elements, each described or evaluated in the attached EA on the pages referenced. The proposed action is expected to begin in 1997 and will be completed within three years: design and construction of a new facility at the Central Facility Area of the INEL; operation of the facility, including instrument receipt, inspections and repairs, precision testing and calibration, and storage and issuance. The selected action will result in no significant environmental impacts

  18. ISS Ammonia Leak Detection Through X-Ray Fluorescence

    Science.gov (United States)

    Camp, Jordan; Barthelmy, Scott; Skinner, Gerry

    2013-01-01

    Ammonia leaks are a significant concern for the International Space Station (ISS). The ISS has external transport lines that direct liquid ammonia to radiator panels where the ammonia is cooled and then brought back to thermal control units. These transport lines and radiator panels are subject to stress from micrometeorites and temperature variations, and have developed small leaks. The ISS can accommodate these leaks at their present rate, but if the rate increased by a factor of ten, it could potentially deplete the ammonia supply and impact the proper functioning of the ISS thermal control system, causing a serious safety risk. A proposed ISS astrophysics instrument, the Lobster X-Ray Monitor, can be used to detect and localize ISS ammonia leaks. Based on the optical design of the eye of its namesake crustacean, the Lobster detector gives simultaneously large field of view and good position resolution. The leak detection principle is that the nitrogen in the leaking ammonia will be ionized by X-rays from the Sun, and then emit its own characteristic Xray signal. The Lobster instrument, nominally facing zenith for its astrophysics observations, can be periodically pointed towards the ISS radiator panels and some sections of the transport lines to detect and localize the characteristic X-rays from the ammonia leaks. Another possibility is to use the ISS robot arm to grab the Lobster instrument and scan it across the transport lines and radiator panels. In this case the leak detection can be made more sensitive by including a focused 100-microampere electron beam to stimulate X-ray emission from the leaking nitrogen. Laboratory studies have shown that either approach can be used to locate ammonia leaks at the level of 0.1 kg/day, a threshold rate of concern for the ISS. The Lobster instrument uses two main components: (1) a microchannel plate optic (also known as a Lobster optic) that focuses the X-rays and directs them to the focal plane, and (2) a CCD (charge

  19. Validation of ultraviolet radiation budgets using satellite observations from the OMI instrument

    International Nuclear Information System (INIS)

    Den Outer, P.N.; Van Dijk, A.; Slaper, H.

    2008-11-01

    Satellite retrieval of ozone, clouds, aerosols and ground albedo allows the modelling of ultraviolet (UV)-doses received at the ground. UV-doses derived from satellite observations are highly useful in analyzing regional differences in the effects of ozone depletion and climate change on the biologically effective UV-radiation levels. RIVM has developed and used UV-mapping and UV-risk mapping techniques in environmental assessments in evaluating the effects of ozone depletion and climate change. This project provides a validation study on the OMUVB product by means of a comparison with ground-based measurements. This validation should demonstrate if the OMUVB product can be used from the perspective of long-term environmental trend assessments. Comparing ground-based UV-measurements with the OMUVB product, we show that the product consistently overestimates the UV-doses received at the ground in Europe. The systematic comparison with data from 8 European sites shows on average a 15% overestimate in the yearly integrated UV with a site-to-site variability of around 8%. For four of the more northern sites the overestimation in yearly doses is between 5-10%, and for the four sites that are more southern the deviation is 20-27%. Using the ozone and reflectivity data from the OMI-instrument (Ozone Monitoring Instrument) in combination with the AMOUR-algorithm (Assessment Model for Ultraviolet radiation and Risks) shows smaller overestimates of on average 5-6% with a similar variability between the sites. The variability between sites is largely caused by aerosol and albedo effects and is reduced to 3% if local data on aerosol and albedo are used. The overestimates in the OMUVB product are primarily due to too low (tropospheric) aerosol loads used for the European sites. In addition, our comparison shows that under heavy clouded conditions the cloud modification factors are too high. This contributes to the overall too high UV-doses of the OMUVB product. Environmental

  20. Validation of ultraviolet radiation budgets using satellite observations from the OMI instrument

    Energy Technology Data Exchange (ETDEWEB)

    Den Outer, P.N.; Van Dijk, A.; Slaper, H.

    2008-11-15

    Satellite retrieval of ozone, clouds, aerosols and ground albedo allows the modelling of ultraviolet (UV)-doses received at the ground. UV-doses derived from satellite observations are highly useful in analyzing regional differences in the effects of ozone depletion and climate change on the biologically effective UV-radiation levels. RIVM has developed and used UV-mapping and UV-risk mapping techniques in environmental assessments in evaluating the effects of ozone depletion and climate change. This project provides a validation study on the OMUVB product by means of a comparison with ground-based measurements. This validation should demonstrate if the OMUVB product can be used from the perspective of long-term environmental trend assessments. Comparing ground-based UV-measurements with the OMUVB product, we show that the product consistently overestimates the UV-doses received at the ground in Europe. The systematic comparison with data from 8 European sites shows on average a 15% overestimate in the yearly integrated UV with a site-to-site variability of around 8%. For four of the more northern sites the overestimation in yearly doses is between 5-10%, and for the four sites that are more southern the deviation is 20-27%. Using the ozone and reflectivity data from the OMI-instrument (Ozone Monitoring Instrument) in combination with the AMOUR-algorithm (Assessment Model for Ultraviolet radiation and Risks) shows smaller overestimates of on average 5-6% with a similar variability between the sites. The variability between sites is largely caused by aerosol and albedo effects and is reduced to 3% if local data on aerosol and albedo are used. The overestimates in the OMUVB product are primarily due to too low (tropospheric) aerosol loads used for the European sites. In addition, our comparison shows that under heavy clouded conditions the cloud modification factors are too high. This contributes to the overall too high UV-doses of the OMUVB product. Environmental

  1. Health physics instrumentation - a progress report

    International Nuclear Information System (INIS)

    Maushart, R.

    1992-01-01

    Health Physics Instruments have changed rather dramatically in the past decade. On the one hand, technological innovations like Microprocessors, data storage facilities and imaging displays have altered shape, size and appearance of the classical devices, particularly the hand-held ones. On the other hand, instruments are increasingly being considered as an integral part of Radiation Protection procedures and organizations, supporting a smooth and reliable implementation of all necessary measures. This implies ease of operation, and extensive self-checking and performance control features. Since there are different categories of users with quite different degrees of motivation and training, the measuring instruments of the future will have to be adapted to specific types of users. Instruments for 'professional' radiation protection - for example in nuclear power plants and nuclear technology - will differ from instruments used in the radionuclide laboratory, where radiation protection will necessarily have to be done as a 'side-job'. (author)

  2. Time Demand and Radiation Dose in 3D-Fluoroscopy-based Navigation-assisted 3D-Fluoroscopy-controlled Pedicle Screw Instrumentations.

    Science.gov (United States)

    Balling, Horst

    2018-05-01

    Prospective single-center cohort study to record additional time requirements and radiation dose in navigation-assisted O-arm-controlled pedicle screw (PS) instrumentations. The aim of this study was to evaluate amount of extra-time and radiation dose for navigation-assisted PS instrumentations of the thoracolumbosacral spine using O-arm 3D-real-time-navigation (O3DN) compared to non-navigated spinal procedures (NNSPs) with a single C-arm and postoperative computed tomography (CT) scan for controlling PS positions. 3D-navigation is reported to enhance PS insertion accuracy. But time-consuming navigational steps and considerable additional radiation doses seem to limit this modern technique's attraction. A detailed analysis of additional time demand and extra-radiation dose in 3D-navigated spine surgery is not provided in literature, yet. From February 2011 through July 2015, 306 consecutive posterior instrumentations were performed in vertebral levels T10-S1 using O3DN for PS insertion. The duration of procedure-specific navigational steps of the overall collective (I) and the last cohort of 50 consecutive O3DN-surgeries (II) was compared to the average duration of analogous surgical steps in 100 consecutive NNSP using a single C-arm. 3D-radiation dose (dose-length-product, DLP) of navigational and postinstrumentation O-arm scans in group I and II was compared to the average DLP of 100 diagnostic lumbar CT scans. The average presurgical time from patient positioning on the operating table to skin incision was 46.2 ± 10.1 minutes (O3DN, I) and 40.6 ± 9.8 minutes (O3DN, II) versus 30.6 ± 8.3 minutes (NNSP) (P demand of 13.0 minutes compared to NNSP, and with a total DLP below that of a diagnostic lumbar CT scan (P ≈ 0.81). 4.

  3. Precision of quantum tomographic detection of radiation

    Energy Technology Data Exchange (ETDEWEB)

    D' Ariano, G.M. (Dipartimento di Fisica ' ' Alessandro Volta' ' , Via A. Bassi 6, I-27100, Pavia (Italy) Istituto Nazionale di Fisica Nucleare, Sezione di Pavia, Via A. Bassi 6, I-27100, Pavia (Italy)); Macchiavello, Chiara (Dipartimento di Fisica ' ' Alessandro Volta' ' , Via A. Bassi 6, I-27100, Pavia (Italy)); Paris, M.G.A. (Dipartimento di Fisica ' ' Alessandro Volta' ' , Via A. Bassi 6, I-27100, Pavia (Italy))

    1994-11-21

    Homodyne tomography provides an experimental technique for reconstructing the density matrix of the radiation field. Here we analyze the tomographic precision in recovering observables like the photon number, the quadrature, and the phase. We show that tomographic reconstruction, despite providing a complete characterization of the state of the field, is generally much less efficient than conventional detection techniques. ((orig.))

  4. Precision of quantum tomographic detection of radiation

    International Nuclear Information System (INIS)

    D'Ariano, G.M.; Macchiavello, Chiara; Paris, M.G.A.

    1994-01-01

    Homodyne tomography provides an experimental technique for reconstructing the density matrix of the radiation field. Here we analyze the tomographic precision in recovering observables like the photon number, the quadrature, and the phase. We show that tomographic reconstruction, despite providing a complete characterization of the state of the field, is generally much less efficient than conventional detection techniques. ((orig.))

  5. Radiation budget studies using collocated observations from advanced Very High Resolution Radiometer, High-Resolution Infrared Sounder/2, and Earth Radiation Budget Experiment instruments

    Science.gov (United States)

    Ackerman, Steven A.; Frey, Richard A.; Smith, William L.

    1992-01-01

    Collocated observations from the Advanced Very High Resolution Radiometer (AVHRR), High-Resolution Infrared Sounder/2 (HIRS/2), and Earth Radiation Budget Experiment (ERBE) instruments onboard the NOAA 9 satellite are combined to describe the broadband and spectral radiative properties of the earth-atmosphere system. Broadband radiative properties are determined from the ERBE observations, while spectral properties are determined from the HIRS/2 and AVHRR observations. The presence of clouds, their areal coverage, and cloud top pressure are determined from a combination of the HIRS/2 and the AVHRR observations. The CO2 slicing method is applied to the HIRS/2 to determine the presence of upper level clouds and their effective emissivity. The AVHRR data collocated within the HIRS/2 field of view are utilized to determine the uniformity of the scene and retrieve sea surface temperature. Changes in the top of the atmosphere longwave and shortwave radiative energy budgets, and the spectral distribution of longwave radiation are presented as a function of cloud amount and cloud top pressure. The radiative characteristics of clear sky conditions over oceans are presented as a function of sea surface temperature and atmospheric water vapor structure.

  6. Troubleshooting in nuclear instruments

    International Nuclear Information System (INIS)

    1987-06-01

    This report on troubleshooting of nuclear instruments is the product of several scientists and engineers, who are closely associated with nuclear instrumentation and with the IAEA activities in the field. The text covers the following topics: Preamplifiers, amplifiers, scalers, timers, ratemeters, multichannel analyzers, dedicated instruments, tools, instruments, accessories, components, skills, interfaces, power supplies, preventive maintenance, troubleshooting in systems, radiation detectors. The troubleshooting and repair of instruments is illustrated by some real examples

  7. Development of thin dosemeters of CaSO4: Dy for beta radiation detection

    International Nuclear Information System (INIS)

    Campos, L.L.

    1987-01-01

    Thin pellets of CaSO: Dy (0,20mm) were produced and tested in beta radiation fields. The Thermolumiscent (TL) characteristics studied were sensitivity, reproducibility, lower detection limit, linearity of TL response with absorved dose energy dependence. The results show the usefulness of this thin pellets in beta radiation detection. (Author) [pt

  8. Instrument evaluation no. 13. Nuclear enterprises portable meter type PDR

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1978-06-01

    The various radiations encountered in radiological protection cover a wide range of energies and radiation measurements have to be carried out under an equally broad spectrum of environmental conditions. This report is one of a series intended to give information on the performance characteristics of radiological protection instruments, to assist in the selection of appropriate instruments for a given purpose, to interpret the results obtained with such instruments, and, in particular, to know the likely sources and magnitude of errors that might be associated with measurements in the field. The radiation, electrical and environmental characteristics of radiation protection instruments are considered together with those aspects of the construction which make an instrument convenient for routine use. To provide consistent criteria for instrument performance, the range of tests performed on any particular class of instrument, the test methods and the criteria of acceptable performance are based broadly on the appropriate Recommendations of the International Electrotechnical Commission. The radiations in the tests are, in general, selected from the range of reference radiations for instrument calibration being drawn up by the International Standards Organisation. Normally, each report deals with the capabilities and limitations of one model of instrument and no direct comparison with other instruments intended for similar purposes is made, since the significance of particular performance characteristics largely depends on the radiations and environmental conditions in which the instrument is to be used. The results quoted here have all been obtained from tests on instruments in routine production, with the appropriate measurements being made by the NRPB. This report deals with the evaluation of Nuclear Enterprises Portable Dose Rate Meter Type PDR 2

  9. Radiation pager

    International Nuclear Information System (INIS)

    Warren, J.L.; Vadnais, K.G.

    1998-01-01

    Methods of interdicting nuclear materials to date have favored the use of large portal detectors at choke points, or hand carried instruments used by trained personnel for conducting spot searches. Although these methods are effective in some instances, it is often impractical to insert choke points at busy traffic areas, and it is not cost effective to maintain a force of skilled operators whose focus is nuclear interdiction. Recent technology developments are causing profound changes in the philosophy and methods employed for interdicting nuclear materials. Breakthrough advances in the miniaturization of detectors and low power electronics have made possible a new class of small gamma-ray radiation detectors, roughly the size of a message pager, with unprecedented sensitivity for their size. These instruments, named Radiation Pagers TM , are ideally suited for use by untrained individual law enforcement personnel and emergency responders in the course of their regular duties. New tactics that utilize a radiation detector worn by every officer are creating a moving curtain of detection with a significantly higher likelihood of locating illicit nuclear contraband. These individual detectors also provide each officer with a high level of confidence that they are not being unknowingly irradiated in the course of their work. (author)

  10. Development and deployment of the Collimated Directional Radiation Detection System

    Science.gov (United States)

    Guckes, Amber L.; Barzilov, Alexander

    2017-09-01

    The Collimated Directional Radiation Detection System (CDRDS) is capable of imaging radioactive sources in two dimensions (as a directional detector). The detection medium of the CDRDS is a single Cs2LiYCl6:Ce3+ scintillator cell enriched in 7Li (CLYC-7). The CLYC-7 is surrounded by a heterogeneous high-density polyethylene (HDPE) and lead (Pb) collimator. These materials make-up a coded aperture inlaid in the collimator. The collimator is rotated 360° by a stepper motor which enables time-encoded imaging of a radioactive source. The CDRDS is capable of spectroscopy and pulse shape discrimination (PSD) of photons and fast neutrons. The measurements of a radioactive source are carried out in discrete time steps that correlate to the angular rotation of the collimator. The measurement results are processed using a maximum likelihood expectation (MLEM) algorithm to create an image of the measured radiation. This collimator design allows for the directional detection of photons and fast neutrons simultaneously by utilizing only one CLYC-7 scintillator. Directional detection of thermal neutrons can also be performed by utilizing another suitable scintillator. Moreover, the CDRDS is portable, robust, and user friendly. This unit is capable of utilizing wireless data transfer for possible radiation mapping and network-centric applications. The CDRDS was tested by performing laboratory measurements with various gamma-ray and neutron sources.

  11. Radiation dosimetry and spectrometry with superheated emulsions

    International Nuclear Information System (INIS)

    D'Errico, Francesco

    2001-01-01

    Detectors based on emulsions of overexpanded halocarbon droplets in tissue equivalent aqueous gels or soft polymers, known as 'superheated drop detectors' or 'bubble (damage) detectors', have been used in radiation detection, dosimetry and spectrometry for over two decades. Recent technological advances have led to the introduction of several instruments for individual and area monitoring: passive integrating meters based on the optical or volumetric registration of the bubbles, and active counters detecting bubble nucleations acoustically. These advances in the instrumentation have been matched by the progress made in the production of stable and well-specified emulsions of superheated droplets. A variety of halocarbons are employed in the formulation of the detectors, and this permits a wide range of applications. In particular, halocarbons with a moderate degree of superheat, i.e. a relatively small difference between their operating temperature and boiling point, can be used in neutron dosimetry and spectrometry since they are only nucleated by energetic heavy ions such as those produced by fast neutrons. More recently, halocarbons with an elevated degree of superheat have been utilised to produce emulsions that nucleate with much smaller energy deposition and detect low linear energy transfer radiations, such as photons and electrons. This paper reviews the detector physics of superheated emulsions and their applications in radiation measurements, particularly in neutron dosimetry and spectrometry

  12. Graphene Field Effect Transistor-Based Detectors for Detection of Ionizing Radiation

    International Nuclear Information System (INIS)

    Jovanovic, Igor; Cazalas, Edward; Childres, I.; Patil, A.; Koybasi, O.; Chen, Y-P.

    2013-06-01

    We present the results of our recent efforts to develop novel ionizing radiation sensors based on the nano-material graphene. Graphene used in the field effect transistor architecture could be employed to detect the radiation-induced charge carriers produced in undoped semiconductor absorber substrates, even without the need for charge collection. The detection principle is based on the high sensitivity of graphene to ionization-induced local electric field perturbations in the electrically biased substrate. We experimentally demonstrated promising performance of graphene field effect transistors for detection of visible light, X-rays, gamma-rays, and alpha particles. We propose improved detector architectures which could result in a significant improvement of speed necessary for pulsed mode operation. (authors)

  13. Is the aerosol emission detectable in the thermal infrared?

    Science.gov (United States)

    Hollweg, H.-D.; Bakan, S.; Taylor, J. P.

    2006-08-01

    The impact of aerosols on the thermal infrared radiation can be assessed by combining observations and radiative transfer calculations. Both have uncertainties, which are discussed in this paper. Observational uncertainties are obtained for two FTIR instruments operated side by side on the ground during the LACE 1998 field campaign. Radiative transfer uncertainties are assessed using a line-by-line model taking into account the uncertainties of the HITRAN 2004 spectroscopic database, uncertainties in the determination of the atmospheric profiles of water vapor and ozone, and differences in the treatment of the water vapor continuum absorption by the CKD 2.4.1 and MT_CKD 1.0 algorithms. The software package OPAC was used to describe the optical properties of aerosols for climate modeling. The corresponding radiative signature is a guideline to the assessment of the uncertainty ranges of observations and models. We found that the detection of aerosols depends strongly on the measurement accuracy of atmospheric profiles of water vapor and ozone and is easier for drier conditions. Within the atmospheric window, only the forcing of downward radiation at the surface by desert aerosol emerges clearly from the uncertainties of modeling and FTIR measurement. Urban and polluted continental aerosols are only partially detectable depending on the wave number and on the atmospheric water vapor amount. Simulations for the space-borne interferometer IASI show that only upward radiation above transported mineral dust aloft emerges out of the uncertainties. The detection of aerosols with weak radiative impact by FTIR instruments like ARIES and OASIS is made difficult by noise as demonstrated by the signal to noise ratio for clean continental aerosols. Altogether, the uncertainties found suggest that it is difficult to detect the optical depths of nonmineral and unpolluted aerosols.

  14. Composite scintillators for detection of ionizing radiation

    Science.gov (United States)

    Dai, Sheng [Knoxville, TN; Stephan, Andrew Curtis [Knoxville, TN; Brown, Suree S [Knoxville, TN; Wallace, Steven A [Knoxville, TN; Rondinone, Adam J [Knoxville, TN

    2010-12-28

    Applicant's present invention is a composite scintillator having enhanced transparency for detecting ionizing radiation comprising a material having optical transparency wherein said material comprises nano-sized objects having a size in at least one dimension that is less than the wavelength of light emitted by the composite scintillator wherein the composite scintillator is designed to have selected properties suitable for a particular application.

  15. Radiation geophysics Implementation of the theory

    International Nuclear Information System (INIS)

    Anon.

    2004-01-01

    The gamma spectrometry allows to measure directly a source from the surface of the ground without penetration at great deepness. The fact that it collects data in surface allows to establish links between contrasts measured for the radioelements and the cartography of the geology of the rocky substratum or formations in, surface and the modifications associated to the ore deposits. Each rock or materials contents radioactive elements. the gamma spectrometer is conceived to detect the gamma radiation emitted by these radioactive elements and allows to class precisely the detected radiations according to the energy they emit. It is this function of classification that distinguishes the spectrometer from the others instruments used to measure only the whole radioactivity. (N.C.)

  16. Perspective of radiation processing

    International Nuclear Information System (INIS)

    Zhang Manwei

    1987-01-01

    The area of the applications of radiation techniques is very wide. This paper only relates to the applications of radiation techniques in industries including radiation chemical industry, radiation processing of foods and environmental protection by radiation, but the nuclear instruments and the instrumentations of radiation are out-side of our study. (author)

  17. Dosimetry of ionizing radiations by Electron paramagnetic resonance

    International Nuclear Information System (INIS)

    Azorin N, J.

    2005-01-01

    In this work, some historical and theoretical aspects about the Electron Paramagnetic Resonance (EPR), its characteristics, the resonance detection, the paramagnetic species, the radiation effects on inorganic and organic materials, the diagrams of the instrumentation for the EPR detection, the performance of an EPR spectrometer, the coherence among EPR and dosimetry and, practical applications as well as in the food science there are presented. (Author)

  18. Calibration of dosemeters and survey instruments for photon

    International Nuclear Information System (INIS)

    Alamares, A.L.; Caseria, E.S.

    1995-01-01

    The Philippine Nuclear Research Institute (PNRI), the country's regulatory agency, through its Radiation Protection Unit of the Nuclear Regulations Licensing and Safeguard Division provides the calibration services of nuclear instruments used by various institutions. The periodic calibration and standardization of radiation and protection survey instruments are done to insure correct and valid radiation readings. It is also a regulatory requirement for radiation workers to use only operable and precalibrated survey instruments for their work with radioactive materials. The PNRI maintains and operates the Secondary Standard Dosimetry Laboratory (SSDL). It provides the periodic calibration and standardization of radiation monitoring and protection survey instruments, and also the radiological hazard and performance evaluation surveys of radiotherapy facilities and others. For the calibration of survey instruments, the standard sources of Cs-137 and Co-60 are used. The calibration procedures for survey meters and pocket dosimeters are explained. The clients served are shown. The personnel dosimetry using film badges, the application of ICRU operational quantities, and the problems encountered and recommendations are reported. (K.I.)

  19. Legal instruments for controlling exposure of workers to ionizing radiations in mining and its associated industries

    International Nuclear Information System (INIS)

    Yusoff Ismail

    1994-01-01

    Briefly, the existing legal instruments for protection of workers in mining and its associated activities are given. Further, major provisions of the laws relevant to the protection of workers against ionizing radiations in mining and its associated activities are detailed. Finally, practical framework developed by the Atomic Energy Licensing Board, for implementation and enforcement is described

  20. Electrical Versus Optical: Comparing Methods for Detecting Terahertz Radiation Using Neon Lamps

    Science.gov (United States)

    Slocombe, L. L.; Lewis, R. A.

    2018-05-01

    Terahertz radiation impinging on a lit neon tube causes additional ionization of the encapsulated gas. As a result, the electrical current flowing between the electrodes increases and the glow discharge in the tube brightens. These dual phenomena suggest two distinct modes of terahertz sensing. The electrical mode simply involves measuring the electrical current. The optical mode involves monitoring the brightness of the weakly ionized plasma glow discharge. Here, we directly compare the two detection modes under identical experimental conditions. We measure 0.1-THz radiation modulated at frequencies in the range 0.1-10 kHz, for lamp currents in the range 1-10 mA. We find that electrical detection provides a superior signal-to-noise ratio while optical detection has a faster response. Either method serves as the basis of a compact, robust, and inexpensive room-temperature detector of terahertz radiation.

  1. Design of a wireless radiation telemetry system

    Energy Technology Data Exchange (ETDEWEB)

    Chiang, H H [Chung Yuan Christian Coll. of Science and Engineering, Chung-Li, Taiwan; Chang, J K

    1976-12-01

    The wireless radiation telemetry system can be operated in all seasons. It is designed for the measurement of radiation intensities up to millicurie order at a distance of 1 Km or less. Its measuring error is +-0.01 percent deviation from the count rate of the typical direct-detecting instrument with the same radiation source. This error indicates that the accuracy is high enough for practical uses. This system is cheaper and more flexible, comparing with the corresponding cable facility. The line-of-sight transmission distance can be longer if the transmitting power is appropriately increased. All pulse type radiation detectors can be used as the input section of this system.

  2. Detection of time-varying harmonic amplitude alterations due to spectral interpolations between musical instrument tones.

    Science.gov (United States)

    Horner, Andrew B; Beauchamp, James W; So, Richard H Y

    2009-01-01

    Gradated spectral interpolations between musical instrument tone pairs were used to investigate discrimination as a function of time-averaged spectral difference. All possible nonidentical pairs taken from a collection of eight musical instrument sounds consisting of bassoon, clarinet, flute, horn, oboe, saxophone, trumpet, and violin were tested. For each pair, several tones were generated with different balances between the primary and secondary instruments, where the balance was fixed across the duration of each tone. Among primary instruments it was found that changes to horn and bassoon [corrected] were most easily discriminable, while changes to saxophone and trumpet timbres were least discriminable. Among secondary instruments, the clarinet had the strongest effect on discrimination, whereas the bassoon had the least effect. For primary instruments, strong negative correlations were found between discrimination and their spectral incoherences, suggesting that the presence of dynamic spectral variations tends to increase the difficulty of detecting time-varying alterations such as spectral interpolation.

  3. Nitrogen deficiency detection using reflected shortwave radiation from irrigated corn canopies

    International Nuclear Information System (INIS)

    Blackmer, T.M.; Schepers, J.S.; Varvel, G.E.; Walter-Shea, E.A.

    1996-01-01

    Techniques that measure the N status of corn (Zea mays L.) can aid in management decisions that have economic and environmental implications. This study was conducted to identify reflected electromagnetic wavelengths most sensitive to detecting N deficiencies in a corn canopy with the possibility for use as a management tool. Reflected shortwave radiation was measured from an irrigated corn N response trial with four hybrids and five N rates at 0, 40, 80, 120, and 160 kg N ha -1 in 1992 and 0, 50, 100, 150, and 200 kg N ha -1 in 1993. A portable spectroradiometer was used to measure reflected radiation (400-1100 nm in 1992, 350-1050 nm in 1993) from corn canopies at approximately the R5 growth stage. Regression analyses revealed that reflected radiation near 550 and 710 nm was superior to reflected radiation near 450 or 650 nm for detecting N deficiencies. The ratio of light reflectance between 550 and 600 nm to light reflectance between 800 and 900 nm also provided sensitive detection of N stress. In 1993, an inexpensive photometric cell, which has peak sensitivity to light centered at 550 nm, was also used to measure reflected radiation from a corn canopy. Photometric cell readings correlated with relative grain yield (P < 0.001, r 2 = 0.74), but more research will be required to develop procedures to account for varying daylight conditions. These results provide information needed for the development of variable-rate fertilizer N application technology. (author)

  4. Apparatus and method for the simultaneous detection of neutrons and ionizing electromagnetic radiation

    Science.gov (United States)

    Bell, Zane W.

    2000-01-01

    A sensor for simultaneously detecting neutrons and ionizing electromagnetic radiation comprising: a sensor for the detection of gamma radiation, the sensor defining a sensing head; the sensor further defining an output end in communication with the sensing head; and an exterior neutron-sensitive material configured to form around the sensing head; wherein the neutron-sensitive material, subsequent to the capture of the neutron, fissions into an alpha-particle and a .sup.7 Li ion that is in a first excited state in a majority of the fissions, the first excited state decaying via the emission of a single gamma ray at 478 keV which can in turn be detected by the sensing head; and wherein the sensing head can also detect the ionizing electromagnetic radiation from an incident radiation field without significant interference from the neutron-sensitive material. A method for simultaneously detecting neutrons and ionizing electromagnetic radiation comprising the steps of: providing a gamma ray sensitive detector comprising a sensing head and an output end; conforming an exterior neutron-sensitive material configured to form around the sensing head of the detector; capturing neutrons by the sensing head causing the neutron-sensitive material to fission into an alpha-particle and a .sup.7 Li ion that is in a first excited state in a majority of the fissions, the state decaying via the emission of a single gamma ray at 478 keV; sensing gamma rays entering the detector through the neutron-sensitive material; and producing an output through a readout device coupled to the output end; wherein the detector provides an output which is proportional to the energy of the absorbed ionizing electromagnetic radiation.

  5. Detection and measurement of ionizing radiation by the Radioactive Waste Management Centre

    International Nuclear Information System (INIS)

    Mudra, Josef

    2013-01-01

    The following topics are dealt with: Basic properties of radionuclides and selection of suitable detectors; radiation characteristics of sealed sources (radiation detection, dose rate measurement, surface contamination measurement, gamma spectroscopy); non-destructive analysis (segment gamma scanner, digital radiography); destructive analysis; radiation monitoring of humans and workplaces; and dosimetric monitoring of workplace surroundings and discharges. (orig.)

  6. Stochastic Radiative Transfer Model for Contaminated Rough Surfaces: A Framework for Detection System Design

    Science.gov (United States)

    2013-11-01

    example for the detection of a potassium chlorate contaminated “car” with a CO2 tunable laser system. 15. SUBJECT TERMS Radiative transfer...detector m-out-of-n detector Potassium chlorate Probability theory System performance Probability of detection and false alarm iii...for the detection of a potassium chlorate contaminated “car” with a CO2 tunable laser system. Subject Terms Radiative transfer, contaminated

  7. Development of Sensor Technology and Its Application for Nuclear Radiation Detection

    International Nuclear Information System (INIS)

    Hiskia

    2007-01-01

    Radiation is energy in the form of waves or moving subatomic particles. Radiation can be ionizing or nonionizing radiation, depending on its effect on atomic matter. Because radiation cannot be seen, felt, tasted, heard or smelled, even at lethal levels, radiations detection devices must be used to alert those exposed to radiation. The measurement of radioactivity in the environment is a regulatory requirement around sites where significant amounts of radioactive materials are used or stored. Recently, advent in microelectronics and material technology has enabled to produce small sensor or microsensor, sensitive, accurate, and integrated in a chip or substrate. Development of radiation sensor technology using thin/thick film and micromachining technique was described in this paper. Indonesian capabilities in radiation sensor research and development and opportunities for commercialization also given. (author)

  8. The Development of Sensor Technology and Application to Detect Nuclear Radiation

    International Nuclear Information System (INIS)

    Hiskia

    2007-01-01

    Radiation is energy in the form of waves or moving subatomic particles. Radiation can be ionizing or non-ionizing radiation, depending on its effect on atomic matter. Because radiation cannot be seen, felt, tasted, heard or smelled, even at lethal levels, radiations detection devices must be used to alert those exposed to radiation. The measurement of radioactivity in the environment is a regulatory requirement around sites where significant amounts of radioactive materials are used or stored. Recently, advent in microelectronics and material technology has enabled to produce small sensor or microsensor, sensitive, accurate, and integrated in a chip or substrate. Development of radiation sensor technology using thin/thick film and micromachining technique was described in this paper. Indonesian capabilities in radiation sensor research and development and opportunities for commercialization also given. (author)

  9. Flexible Receiver Radiation Detection System (FRRDS) Users Manual

    International Nuclear Information System (INIS)

    Troyer, G.L.

    1996-01-01

    The Flexible Receiver Radiation Detection System (FRRDS) comprises a control computer, a remote data acquisition subsystem, and three hyperpure germanium gamma radiation detectors. The scope of this document is the description of various steps for the orderly start-up, use, and shutdown of the FRRDS. Only those items necessary for these oprations are included. This document is a companion to WHC-SD-W151-UM-002, 'Operating Instructions for the 42 Inch Flexible Receiver,' WHC-SD-W151-UM-003, 'Operating Instructions for the 4-6 Inch Flexible Receiver,' and the vendor supplied system users guide (Ref. 6)

  10. Detection of radiation processing in onions

    International Nuclear Information System (INIS)

    Duchacek, V.

    1985-01-01

    Two breeds of onions were used for irradiation. Both breeds were divided into two parts - the first was irradiated with a dose of 80 Gy and the second served as a control. The two parts were stored under the same conditions. Conductometry, liquid chromatography and spectrophotometry were used for detecting the radiation processing of the onions. Only from the spectrophotometric determination of 2-desoxysaccharides it was possible to safely distinguish irradiated onions from non-irradiated controls throughout storage time. (E.S.)

  11. Monitoring Space Radiation Hazards with the Responsive Environmental Assessment Commercially Hosted (REACH) Project

    Science.gov (United States)

    Mazur, J. E.; Guild, T. B.; Crain, W.; Crain, S.; Holker, D.; Quintana, S.; O'Brien, T. P., III; Kelly, M. A.; Barnes, R. J.; Sotirelis, T.

    2017-12-01

    The Responsive Environmental Assessment Commercial Hosting (REACH) project uses radiation dosimeters on a commercial satellite constellation in low Earth orbit to provide unprecedented spatial and time sampling of space weather radiation hazards. The spatial and time scales of natural space radiation environments coupled with constraints for the hosting accommodation drove the instrumentation requirements and the plan for the final orbital constellation. The project has delivered a total of thirty two radiation dosimeter instruments for launch with each instrument containing two dosimeters with different passive shielding and electronic thresholds to address proton-induced single-event effects, vehicle charging, and total ionizing dose. There are two REACH instruments currently operating with four more planned for launch by the time of the 2017 meeting. Our aim is to field a long-lived system of highly-capable radiation detectors to monitor the hazards of single-event effects, total ionizing dose, and spacecraft charging with maximized spatial coverage and with minimal time latency. We combined a robust detection technology with a commercial satellite hosting to produce a new demonstration for satellite situational awareness and for other engineering and science applications.

  12. Health physics instruments: what are the current needs

    International Nuclear Information System (INIS)

    Armantrout, G.A.

    1982-01-01

    Health Physics instruments are used to measure the risk which may be incurred by an individual exposed to a given radiation field. The response of the instrument sensors will differ markedly from actual human risk factors for a variety of reasons, and this requires the use of instrument modifications and conversion factors. The values of these conversion factors continue to be updated and will likely change in the future. To accommodate the effects of different types of radiation and new conversion and usage factors, new instruments should be able to determine the type, energy distribution, and direction of incoming radiation and then apply the proper weighting factors to determine relative human risk. Such instrumentation will need to utilize modern sensor elements and microprocessor electronics

  13. An integrated circuit/microsystem/nano-enhanced four species radiation sensor for inexpensive fissionable material detection

    Science.gov (United States)

    Waguespack, Randy Paul

    2011-12-01

    Small scale radiation detectors sensitive to alpha, beta, electromagnetic, neutron radiation are needed to combat the threat of nuclear terrorism and maintain national security. There are many types of radiation detectors on the market, and the type of detector chosen is usually determined by the type of particle to be detected. In the case of fissionable material, an ideal detector needs to detect all four types of radiation, which is not the focus of many detectors. For fissionable materials, the two main types of radiation that must be detected are gamma rays and neutrons. Our detector uses a glass or quartz scintillator doped with 10B nanoparticles to detect all four types of radiation particles. Boron-10 has a thermal neutron cross section of 3,840 barns. The interaction between the neutron and boron results in a secondary charge particle in the form of an alpha particle to be emitted, which is detectable by the scintillator. Radiation impinging on the scintillator matrix produces varying optical pulses dependent on the energy of the particles. The optical pulses are then detected by a photomultiplier (PM) tube, creating a current proportional to the energy of the particle. Current pulses from the PM tube are differentiated by on-chip pulse height spectroscopy, allowing for source discrimination. The pulse height circuitry has been fabricated with discrete circuits and designed into an integrated circuit package. The ability to replace traditional PM tubes with a smaller, less expensive photomultiplier will further reduce the size of the device and enhance the cost effectiveness and portability of the detector.

  14. Sulfur dioxide emissions from Peruvian copper smelters detected by the ozone monitoring instrument

    NARCIS (Netherlands)

    Carn, S.A.; Krueger, A.J.; Krotkov, N.A.; Yang, Kai; Levelt, P.F.

    2007-01-01

    We report the first daily observations of sulfur dioxide (SO2) emissions from copper smelters by a satellite-borne sensor - the Ozone Monitoring Instrument (OMI) on NASA's EOS/Aura spacecraft. Emissions from two Peruvian smelters (La Oroya and Ilo) were detected in up to 80% of OMI overpasses

  15. Gamma radiation in apartments

    International Nuclear Information System (INIS)

    Grindborg, J.-E.

    1983-05-01

    This investigation forms the basis for the description of methods for the detection of gamma radiation. The aim is to control that the dose limit will not exceed 50 μR/h in a room where people reside. The distribution of dose rates in different rooms has been calculated and the results have been compared with experimental data. Various instruments have been calibrated and their specifications are discussed. (G.B.)

  16. Development of a New Radiation Measuring Instrument for the Column Scanning Technique - NibraS

    International Nuclear Information System (INIS)

    Benahmed, A.; Alami, R.

    2013-06-01

    The radiation measuring instrument, called Nibras, associated to a special data processing software for Column scanning is a new data acquisition system. It was developed to scan and to plot density profiles, inside a distillation column, which illustrates the activity of the radiations able to cross the contents of the column. Nibras is an autonomous data logger with very low power consumption, using only 4 batteries of 1.5 V and can be operated for more than 120 hours continuously; this presents an ecological and economic importance. Another particularity of Nibras consists in its dual functionality to display counting rates indicating the existence and the intensity of radiation; and to perform a real-time control in industrial plant particularly in oil distillation columns, due to its user-friendly software. This last provides essential data to optimize the performance of the columns, extend column run times, track the performance-deteriorating effects of fouling and solids deposition, and to identify maintenance requirements well in advance of scheduled turnarounds. This on-line knowledge can reduce repair downtime significantly. (authors)

  17. Fuzzy associative memories for instrument fault detection

    International Nuclear Information System (INIS)

    Heger, A.S.

    1996-01-01

    A fuzzy logic instrument fault detection scheme is developed for systems having two or three redundant sensors. In the fuzzy logic approach the deviation between each signal pairing is computed and classified into three fuzzy sets. A rule base is created allowing the human perception of the situation to be represented mathematically. Fuzzy associative memories are then applied. Finally, a defuzzification scheme is used to find the centroid location, and hence the signal status. Real-time analyses are carried out to evaluate the instantaneous signal status as well as the long-term results for the sensor set. Instantaneous signal validation results are used to compute a best estimate for the measured state variable. The long-term sensor validation method uses a frequency fuzzy variable to determine the signal condition over a specific period. To corroborate the methodology synthetic data representing various anomalies are analyzed with both the fuzzy logic technique and the parity space approach. (Author)

  18. Calibration of ratemeters used for gamma radiation detection

    International Nuclear Information System (INIS)

    Hantanirina, P.A.

    2017-01-01

    The Secondary Standard Dosimetry Laboratory (SSDL) of INSTN-Madagascar is in charge of the calibration of every dosimetry measurement instrument in hospitals and companies using radioactive sources in Madagascar. It has a secondary standard delivered and calibrated by a Primary Standard Laboratory in Dosimetry (PSLD). This standard is used to compare its reference values with those displayed on the instruments to be calibrated. During our training period, three (3) ratemeters were calibrated, the Graetz X5DE, the Graetz X5C and the Identifinder 2. We have determined the calibration factor for every ratemeter by doing calculation with the reference value. By using the three surveymeters for direct radiations measurements, it has been found that the difference between the displayed values and the real values for every ratemeter does not exceed the tolerance limit which is 20 %. Then we can conclude that these ratemeters are still in good condition of functioning. Concerning the calibration factor curve N_k with the K_a_i_r , we can observe that for the Graetz X5C ratemeter, this curve is almost constant. As well as for the linearity, it is still the Graetz X5C ratemeter which is linear almost integrally for the measured and calculated dose rate values. So we can say that this ratemeter is the most recommended for the radiations measurements.This work which has been carried within the framework of collaboration between the section PNAE (Physique Nucléaire Appliquée et Environnement) of the University of Antananarivo and INSTN-Madagascar has been a good and rewarding experience which allowed us to put into practice all knowledges acquired during our years of studies. [fr

  19. EPR spectroscopy for the detection of foods treated with ionising radiation

    International Nuclear Information System (INIS)

    Stachowicz, W.; Burlinska, G.; Michalik, J.; Dziedzic-Goclawska, A.; Ostrowski, K.

    1996-01-01

    The advantage of electron paramagnetic resonance spectroscopy (EPR or ESR) as a tool for the control of irradiated food lies in its sensitivity and accuracy. Ionising radiation produces, in irradiated materials, paramagnetic species of different kinds, i.e. radicals, radical-ions and paramagnetic centres, which can be measured by EPR but most of them are not stable enough to be used for the detection of irradiation. It is because radiation-induced paramagnetic species are thermodynamically less stable than surrounding molecules and take part in fast radiolytic reactions leading to the formation of final diamagnetic products that they are not detectable by the EPR method. Most of organic radicals produced by radiation in the liquid phase ae unstable but if the unpaired electron is incorporated into the complex polymeric system as in peptides and polysaccharides and is structurally isolated from the water, its stability is markedly increased. Since 1954 it is known that ionising radiation produces paramagnetic entities in biological materials, cells and tissues and some are stable enough to be observed by EPR spectroscopy at room temperature. The present paper describes and discusses that part of results obtained by this group during the period of ADMIT activity (1989-94) which are original and may be useful to those who will be working in the near future on the development of uniform control systems for the detection of irradiated food. The intention was to focus attention on these facts and data which influence the certainty of the detection in both positive and negative manner. (author)

  20. PRD3000: A novel Personnel Radiation Detector with Radiation Exposure Monitoring

    International Nuclear Information System (INIS)

    Fallu-Labruyere, A.; Micou, C.; Schulcz, F.; Fellinger, J.

    2015-01-01

    PRD3000 TM is a novel Personal Radiation Detector (PRD) with personnel radiation dose exposure monitoring. It is intended for First Responders, Law Enforcement, Customs Inspectors protecting critical infrastructures for detecting unexpected radioactive sources, who also need real time Hp(10) dose equivalent information. Traditional PRD devices use scintillator materials instrumented through either a photomultiplier tube or a photodiode photodetector. While the former is bulky and sensitive to magnetic fields, the latter has to compromise radiation sensitivity and energy threshold given its current noise per unit of photo-detection surface. Recently, solid state photodetectors (SiPM), based on arrays of Geiger operated diodes, have emerged as a scalable digital photodetector for photon counting. Their strong breakdown voltage temperature dependence (on the order of tens of milli-volts per K) has however limited their use for portable instruments where strong temperature gradients can be experienced, and limited power is available to temperature stabilize. The PRD3000 is based on the industry standard DMC3000 active dosimeter that complies with IEC 61526 Ed. 3 and ANSI 42.20 for direct reading personal dose equivalent meters and active personnel radiation monitors. An extension module is based on a CsI(Tl) scintillator readout by a temperature compensated SiPM. Preliminary nuclear tests combined with a measured continuous operation in excess of 240 hours from a single AAA battery cell indicate that the PRD3000 complies with the IEC 62401 Ed.2 and ANSI 42.32 without sacrificing battery life time. We present a summary of the device test results, starting with performance stability over a temperature range of - 20 deg. C to 50 deg. C, false alarm rates and dynamic response time. (authors)

  1. PRD3000: A novel Personnel Radiation Detector with Radiation Exposure Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Fallu-Labruyere, A.; Micou, C.; Schulcz, F.; Fellinger, J. [Mirion Technologies - MGPI SA (France)

    2015-07-01

    PRD3000{sup TM} is a novel Personal Radiation Detector (PRD) with personnel radiation dose exposure monitoring. It is intended for First Responders, Law Enforcement, Customs Inspectors protecting critical infrastructures for detecting unexpected radioactive sources, who also need real time Hp(10) dose equivalent information. Traditional PRD devices use scintillator materials instrumented through either a photomultiplier tube or a photodiode photodetector. While the former is bulky and sensitive to magnetic fields, the latter has to compromise radiation sensitivity and energy threshold given its current noise per unit of photo-detection surface. Recently, solid state photodetectors (SiPM), based on arrays of Geiger operated diodes, have emerged as a scalable digital photodetector for photon counting. Their strong breakdown voltage temperature dependence (on the order of tens of milli-volts per K) has however limited their use for portable instruments where strong temperature gradients can be experienced, and limited power is available to temperature stabilize. The PRD3000 is based on the industry standard DMC3000 active dosimeter that complies with IEC 61526 Ed. 3 and ANSI 42.20 for direct reading personal dose equivalent meters and active personnel radiation monitors. An extension module is based on a CsI(Tl) scintillator readout by a temperature compensated SiPM. Preliminary nuclear tests combined with a measured continuous operation in excess of 240 hours from a single AAA battery cell indicate that the PRD3000 complies with the IEC 62401 Ed.2 and ANSI 42.32 without sacrificing battery life time. We present a summary of the device test results, starting with performance stability over a temperature range of - 20 deg. C to 50 deg. C, false alarm rates and dynamic response time. (authors)

  2. Design of a spreader bar crane-mounted gamma-ray radiation detection system

    Energy Technology Data Exchange (ETDEWEB)

    Grypp, Matthew D., E-mail: iglowgreen@neo.tamu.edu; Marianno, Craig M., E-mail: marianno@tamu.edu; Poston, John W., E-mail: j-poston@tamu.edu; Hearn, Gentry C., E-mail: ghearn@riacc.com

    2014-04-11

    Over 95% of imports entering the United States from outside North America arrive by sea at 329 ports of entry. These imports are packaged in more than 11 million cargo containers. Radiation portals monitors routinely scan cargo containers leaving port on specially-designed trucks. To accelerate the process, some commercial entities have placed detection systems on the spreader-bar cranes (SBCs) used to offload. Little is known about the radiation background profiles of systems operating on these cranes. To better understand the operational characteristics of these radiation detection systems; a research team from Texas A and M University (TAMU) mounted three thallium-doped sodium iodide [NaI(Tl)] detectors on an SBC at the Domestic Nuclear Detection Office's (DNDO) test track facility at the Port of Tacoma (PoT). These detectors were used to monitor background radiation levels and continuously recorded data during crane operations using a custom-built software package. Count rates and spectral data were recorded for various crane heights over both land and water. The results of this research created a background profile in which count rate was heavily dependent on position demonstrating how detector readings changed in the operational environment.

  3. Inconsistencies in net radiation estimates from use of several models of instruments in a desert environment

    International Nuclear Information System (INIS)

    Kustas, W.P.; Prueger, J.H.; Hipps, L.E.; Hatfield, J.L.; Meek, D.

    1998-01-01

    Studies of surface energy and water balance generally require an accurate estimate of net radiation and its spatial distribution. A project quantifying both short term and seasonal water use of shrub and grass vegetation in the Jornada Experimental Range in New Mexico prompted a study to compare net radiation observations using two types of net radiometers currently being used in research. A set of 12 REBS net radiometers were compared with each other and one Swissteco, over wet and dry surfaces in an arid landscape under clear skies. The set of REBS exhibited significant differences in output over both surfaces. However, they could be cross calibrated to yield values within 10 W m −2 , on average. There was also a significant bias between the REBS and Swissteco over a dry surface, but not over a wet one. The two makes of instrument could be made to agree under the dry conditions by using regression or autoregression techniques. However, the resulting equations would induce bias for the wet surface condition. Thus, it is not possible to cross calibrate these two makes of radiometer over the range of environmental conditions observed. This result indicates that determination of spatial distribution of net radiation over a variable surface should be made with identical instruments which have been cross calibrated. The need still exists for development of a radiometer and calibration procedures which will produce accurate and consistent measurements over a range of surface conditions. (author)

  4. Some emergency instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Burgess, P H

    1986-10-01

    The widespread release of activity and the resultant spread of contamination after the Chernobyl accident resulted in requests to NRPB to provide instruments for, and expertise in, the measurement of radiation. The most common request was for advice on the usefulness of existing instruments, but Board staff were also involved in their adaptation or in the development of new instruments specially to meet the circumstances of the accident. The accident occurred on 26 April. On 1 May, NRPB was involved at Heathrow Airport in the monitoring of the British students who had returned from Kiev and Minsk. The main purpose was to reassure the students by checking that their persons and belongings did not have significant surface contamination. Additional measurements were also made of iodine activity in thyroid using hand-held detectors or a mobile body monitor. This operation was arranged with the Foreign and Commonwealth Office, which had also received numerous requests for instruments from embassies and consulates in countries close to the scene of the accident. There was concern for the well-being of staff and other United Kingdom nationals who resided in or intended to visit the most affected countries. The board supplied suitable instruments, and the FCO distributed them to embassies. The frequency of environmental monitoring was increased from 29 April in anticipation of contamination and appropriate Board instrumentation was deployed. After the Chernobyl cloud arrived in the UK on 2 May, there were numerous requests from local government, public authorities, private companies and members of the public for information and advice on monitoring equipment and procedures. Some of these requirements could be met with existing equipment but members of the public were usually advised not to proceed. At a later stage, the contamination of foodstuffs and livestock required the development of an instrument capable of detecting low levels of {sup 137}Cs and {sup 134}Cs in food

  5. Technical specifications manual for the MARK-1 pulsed ionizing radiation detection system

    International Nuclear Information System (INIS)

    Lawrence, R.S.; Harker, Y.D.; Jones, J.L.; Hoggan, J.M.

    1993-03-01

    The MARK-1 detection system was developed by the Idaho National Engineering Laboratory for the US Department of Energy Office of Arms Control and Nonproliferation. The completely portable system was designed for the detection and analysis of intense photon emissions from pulsed ionizing radiation sources. This manual presents the technical design specifications for the MARK-1 detection system and was written primarily to assist the support or service technician in the service, calibration, and repair of the system. The manual presents the general detection system theory, the MARK-1 component design specifications, the acquisition and control software, the data processing sequence, and the system calibration procedure. A second manual entitled: Volume 2: Operations Manual for the MARK-1 Pulsed Ionizing Radiation Detection System (USDOE Report WINCO-1108, September 1992) provides a general operational description of the MARK-1 detection system. The Operations Manual was written primarily to assist the field operator in system operations and analysis of the data

  6. Development and Testing of an Air Fluorescence Imaging System for the Detection of Radiological Contamination

    International Nuclear Information System (INIS)

    Inrig, Elizabeth; Koslowsky, Vern; Andrews, Bob; Dick, Michael; Forget, Patrick; Ing, Harry; Hugron, Roger; Wong, Larry

    2011-01-01

    Detection of radionuclides emitting short-range radiation, such as α and low-energy β particles, has always presented a challenge, particularly when such radionuclides are dispersed over a wide area. In this situation, conventional detection methods require the area of interest to be surveyed using a fragile probe at very close range--a slow, error-prone, and potentially dangerous process that may take many hours for a single room. The instrument under development uses a novel approach by imaging radiation-induced fluorescence in the air surrounding a contaminated area, rather than detecting the radiation directly. A robust and portable system has been designed and built that will allow contaminated areas to be rapidly detected and delineated. The detector incorporates position-sensitive photo-multiplier tubes, UV filters, a fast electronic shutter and an aspherical phase mask that significantly increases the depth-of-field. Preliminary tests have been conducted using sealed 241 Am sources of varying activities and surface areas. The details of the instrument design will be described and the results of recent testing will be presented.

  7. Electron beam instrumentation techniques using coherent radiation

    International Nuclear Information System (INIS)

    Wang, D.X.

    1997-01-01

    Much progress has been made on coherent radiation research since coherent synchrotron radiation was first observed in 1989. The use of coherent radiation as a bunch length diagnostic tool has been studied by several groups. In this paper, brief introductions to coherent radiation and far-infrared measurement are given, the progress and status of their beam diagnostic application are reviewed, different techniques are described, and their advantages and limitations are discussed

  8. Pencil-shaped radiation detection ionization chamber

    International Nuclear Information System (INIS)

    Suzuki, A.

    1979-01-01

    A radiation detection ionization chamber is described. It consists of an elongated cylindrical pencil-shaped tubing forming an outer wall of the chamber and a center electrode disposed along the major axis of the tubing. The length of the chamber is substantially greater than the diameter. A cable connecting portion at one end of the chamber is provided for connecting the chamber to a triaxial cable. An end support portion is connected at the other end of the chamber for supporting and tensioning the center electrode. 17 claims

  9. Sampled data spectroscopy (SDS): A new technology for radiation instrumentation

    International Nuclear Information System (INIS)

    Odell, D.M.C.

    1992-01-01

    A new instrumentation architecture for radiation spectroscopy is in the early stages of development at Savannah River. Based upon the same digital sampling techniques used in sonar and radar, sampled data spectroscopy (SDS) has produced Na(I)/PMT spectra with resolution comparable to conventional PHA systems. This work has laid the foundation for extending SDS techniques to solid state detector applications as well. Two-dimensional SDS processes raw, unintegrated detector output pulses to produce both energy and shape information that is used to construct a conventional energy spectrum. System advantages include zero electronic deadtime to support very high count rates, elimination of pulse pile-up peaks, high noise immunity, and digital system stability and reliability. Small size and low power requirements make 2-D SDS anideal technology for portable instrumentation and remote monitoring applications. Applications of potential interest at Savannah River include on-the-spot spill analysis, real-time waste stream monitoring, and personnel and area monitoring below background levels. A three-dimensional sampled data architecture is also being developed. Relying on image analysis and enhancement techniques, 3-D SDS identifies spectral peaks without determining the energy of any individual detector pulses. These techniques also open up a new avenue of exploration for reducing or removing Compton effects from the spectra of single detector systems. The intended application for this technique is waste characterization where lower energy isotopes are often obscured by the Compton scattering from dominant isotopes such as Csl37

  10. Instrument evaluation no. 11. ESI nuclear model 271 C contamination monitor

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1978-06-01

    The various radiations encountered in radiological protection cover a wide range of energies and radiation measurements have to he carried out under an equally broad spectrum of environmental conditions. This report is one of a series intended to give information on the performance characteristics of radiological protection instruments, to assist in the selection of appropriate instruments for a given purpose, to interpret the results obtained with such instruments, and, in particular, to know the likely sources and magnitude of errors that might be associated with measurements in the field. The radiation, electrical and environmental characteristics of radiation protection instruments are considered together with those aspects of the construction which make an instrument convenient for routine use. To provide consistent criteria for instrument performance, the range of tests performed on any particular class of instrument, the test methods and the criteria of acceptable performance are based broadly on the appropriate Recommendations of the International Electrotechnical Commission. The radiations in the tests are, in general, selected from the range of reference radiations for instrument calibration being drawn up by the International Standards Organisation. Normally, each report deals with the capabilities and limitations of one model of instrument and no direct comparison with other instruments intended for similar purposes is made, since the significance of particular performance characteristics largely depends on the radiations and environmental conditions in which the instrument is to be used. The results quoted here have all been obtained from tests on instruments in routine production, with the appropriate measurements being made by the NRPB. This report deals with the ESI Nuclear Model 271 C; a general purpose contamination monitor, comprising a GM tube connected by a coiled extensible cable to a ratemeter

  11. Detection of gamma-ray bursts with the ECLAIRs instrument onboard the space mission SVOM

    International Nuclear Information System (INIS)

    Antier-Farfar, Sarah

    2016-01-01

    Discovered in the early 1970's, gamma-ray bursts (GRBs) are amazing cosmic phenomena appearing randomly on the sky and releasing large amounts of energy mainly through gamma-ray emission. Although their origin is still under debate, they are believed to be produced by some of the most violent explosions in the Universe leading to the formation of stellar black-holes. GRBs are detected by their prompt emission, an intense short burst of gamma-rays (from a few milliseconds to few minutes), and are followed by a lived-afterglow emission observed on longer timescales from the X-ray to the radio domain. My thesis participates to the development of the SVOM mission, which a Chinese-French mission to be launched in 2021, devoted to the study of GRBs and involving space and ground instruments. My work is focussed on the main instrument ECLAIRs, a hard X-ray coded mask imaging camera, in charge of the near real-time detection and localization of the prompt emission of GRBs. During my thesis, I studied the scientific performances of ECLAIRs and in particular the number of GRBs expected to be detected by ECLAIRs and their characteristics. For this purpose, I performed simulations using the prototypes of the embedded trigger algorithms combined with the model of the ECLAIRs instrument. The input data of the simulations include a background model and a synthetic population of gamma-ray bursts generated from existing catalogs (CGRO, HETE-2, Fermi and Swift). As a result, I estimated precisely the ECLAIRs detection efficiency of the algorithms and I predicted the number of GRBs to be detected by ECLAIRs: 40 to 70 GRBs per year. Moreover, the study highlighted that ECLAIRs will be particularly sensitive to the X-ray rich GRB population. My thesis provided additional studies about the localization performance, the rate of false alarm and the characteristics of the triggers of the algorithms. Finally, I also proposed two new methods for the detection of GRBs.The preliminary

  12. Detecting Super-Thin Clouds With Polarized Light

    Science.gov (United States)

    Sun, Wenbo; Videen, Gorden; Mishchenko, Michael I.

    2014-01-01

    We report a novel method for detecting cloud particles in the atmosphere. Solar radiation backscattered from clouds is studied with both satellite data and a radiative transfer model. A distinct feature is found in the angle of linear polarization of solar radiation that is backscattered from clouds. The dominant backscattered electric field from the clear-sky Earth-atmosphere system is nearly parallel to the Earth surface. However, when clouds are present, this electric field can rotate significantly away from the parallel direction. Model results demonstrate that this polarization feature can be used to detect super-thin cirrus clouds having an optical depth of only 0.06 and super-thin liquid water clouds having an optical depth of only 0.01. Such clouds are too thin to be sensed using any current passive satellite instruments.

  13. Evaluation of methods to leak test sealed radiation sources

    International Nuclear Information System (INIS)

    Arbeau, N.D.; Scott, C.K.

    1987-04-01

    The methods for the leak testing of sealed radiation sources were reviewed. One hundred and thirty-one equipment vendors were surveyed to identify commercially available leak test instruments. The equipment is summarized in tabular form by radiation type and detector type for easy reference. The radiation characteristics of the licensed sources were reviewed and summarized in a format that can be used to select the most suitable detection method. A test kit is proposed for use by inspectors when verifying a licensee's test procedures. The general elements of leak test procedures are discussed

  14. Radiation detection using the color changes of lilac spodumene

    International Nuclear Information System (INIS)

    Oliveira, Raquel A.P.; Mello, Ana Carolina S.; Lima, Hestia R.B.R.; Campos, Simara Santos; Souza, Suzana O.

    2009-01-01

    The use of radiation in industrial processes currently offers several advantages in the field of sterilization of medical and pharmaceuticals products, the preservation of food, and a variety of other products widely used in modern society. A dosimetry of confidence is a key parameter for the quality assurance of radiation processing and the irradiated products. This work investigates dosimetric properties in natural spodumene, LiAlSi 2 O 6 , called kunzite, from Minas Gerais State, Brazil. After X irradiation on the samples in powder form was detected a change in color of the crystal where the dose received. This makes a possible viability of this material is applied in research on development of radiation detectors using the change in color of purple spodumene. (author)

  15. Calibration of a Stereo Radiation Detection Camera Using Planar Homography

    Directory of Open Access Journals (Sweden)

    Seung-Hae Baek

    2016-01-01

    Full Text Available This paper proposes a calibration technique of a stereo gamma detection camera. Calibration of the internal and external parameters of a stereo vision camera is a well-known research problem in the computer vision society. However, few or no stereo calibration has been investigated in the radiation measurement research. Since no visual information can be obtained from a stereo radiation camera, it is impossible to use a general stereo calibration algorithm directly. In this paper, we develop a hybrid-type stereo system which is equipped with both radiation and vision cameras. To calibrate the stereo radiation cameras, stereo images of a calibration pattern captured from the vision cameras are transformed in the view of the radiation cameras. The homography transformation is calibrated based on the geometric relationship between visual and radiation camera coordinates. The accuracy of the stereo parameters of the radiation camera is analyzed by distance measurements to both visual light and gamma sources. The experimental results show that the measurement error is about 3%.

  16. Evaluating a radiation monitor for mixed-field environments based on SRAM technology

    CERN Document Server

    Tsiligiannis, G; Bosio, A; Girard, P; Pravossoudovitch, S; Todri, A; Virazel, A; Mekki, J; Brugger, M; Wrobel, F; Saigne, F

    2014-01-01

    Instruments operating in particle accelerators and colliders are exposed to radiations that are composed of particles of different types and energies. Several of these instruments often embed devices that are not hardened against radiation effects. Thus, there is a strong need for mon- itoring the levels of radiation inside the mixed-field radiation areas, throughout different positions. Different metrics exist for measuring the radiation damage induced to electronic devices, such as the Total Ionizing Dose (TID), the Displacement Damage (DD) and of course the fluence of parti- cles for estimating the error rates of the electronic devices among other applications. In this paper, we propose an SRAM based monitor, that is used to define the fluence of High Energy Hadrons (HEH) by detecting Single Event Upsets in the memory array. We evaluated the device by testing it inside the H4IRRAD area of CERN, a test area that reproduces the radiation conditions inside the Large Hadron Collider (LHC) tunnel and its shield...

  17. A novel mobile system for radiation detection and monitoring

    Science.gov (United States)

    Biafore, Mauro

    2014-05-01

    A novel mobile system for real time, wide area radiation surveillance has been developed within the REWARD project, financed within the FP7 programme, theme SEC-2011.1.5-1 (Development of detection capabilities of difficult to detect radioactive sources and nuclear materials - Capability Project). The REWARD sensing units are small, mobile portable units with low energy consumption, which consist of new miniaturized solid-state radiation sensors: a CdZnTe detector for gamma radiation and a high efficiency neutron detector based on novel silicon technologies. The sensing unit is integrated by a wireless communication interface to send the data remotely to a monitoring base station as well as a GPS system to calculate the position of the tag. The system also incorporates middleware and high-level software to provide web-service interfaces for the exchange of information. A central monitoring and decision support system has been designed to process the data from the sensing units and to compare them with historical record in order to generate an alarm when an abnormal situation is detected. A security framework ensures protection against unauthorized access to the network and data, ensuring the privacy of the communications and contributing to the overall robustness and reliability of the REWARD system. The REWARD system has been designed for many different scenarios such as nuclear terrorism threats, lost radioactive sources, radioactive contamination or nuclear accidents. It can be deployed in emergency units and in general in any type of mobile or static equipment, but also inside public/private buildings or infrastructures. The complete system is scalable in terms of complexity and cost and offers very high precision on both the measurement and the location of the radiation. The modularity and flexibility of the system allows for a realistic introduction to the market. Authorities may start with a basic, low cost system and increase the complexity based on their

  18. Reconciling Ground-Based and Space-Based Estimates of the Frequency of Occurrence and Radiative Effect of Clouds around Darwin, Australia

    Energy Technology Data Exchange (ETDEWEB)

    Protat, Alain; Young, Stuart; McFarlane, Sally A.; L' Ecuyer, Tristan; Mace, Gerald G.; Comstock, Jennifer M.; Long, Charles N.; Berry, Elizabeth; Delanoe, Julien

    2014-02-01

    The objective of this paper is to investigate whether estimates of the cloud frequency of occurrence and associated cloud radiative forcing as derived from ground-based and satellite active remote sensing and radiative transfer calculations can be reconciled over a well instrumented active remote sensing site located in Darwin, Australia, despite the very different viewing geometry and instrument characteristics. It is found that the ground-based radar-lidar combination at Darwin does not detect most of the cirrus clouds above 10 km (due to limited lidar detection capability and signal obscuration by low-level clouds) and that the CloudSat radar - Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) combination underreports the hydrometeor frequency of occurrence below 2 km height, due to instrument limitations at these heights. The radiative impact associated with these differences in cloud frequency of occurrence is large on the surface downwelling shortwave fluxes (ground and satellite) and the top-of atmosphere upwelling shortwave and longwave fluxes (ground). Good agreement is found for other radiative fluxes. Large differences in radiative heating rate as derived from ground and satellite radar-lidar instruments and RT calculations are also found above 10 km (up to 0.35 Kday-1 for the shortwave and 0.8 Kday-1 for the longwave). Given that the ground-based and satellite estimates of cloud frequency of occurrence and radiative impact cannot be fully reconciled over Darwin, caution should be exercised when evaluating the representation of clouds and cloud-radiation interactions in large-scale models and limitations of each set of instrumentation should be considered when interpreting model-observations differences.

  19. Instrument evaluation no. 11. ESI nuclear model 271 C contamination monitor

    CERN Document Server

    Burgess, P H

    1978-01-01

    The various radiations encountered in radiological protection cover a wide range of energies and radiation measurements have to he carried out under an equally broad spectrum of environmental conditions. This report is one of a series intended to give information on the performance characteristics of radiological protection instruments, to assist in the selection of appropriate instruments for a given purpose, to interpret the results obtained with such instruments, and, in particular, to know the likely sources and magnitude of errors that might be associated with measurements in the field. The radiation, electrical and environmental characteristics of radiation protection instruments are considered together with those aspects of the construction which make an instrument convenient for routine use. To provide consistent criteria for instrument performance, the range of tests performed on any particular class of instrument, the test methods and the criteria of acceptable performance are based broadly on the a...

  20. Instrument evaluation no. 17. Wallac automatic alarm dosimeter type RAD21

    CERN Document Server

    Burgess, P H

    1980-01-01

    The various radiations encountered in radiological protection cover a wide range of energies and radiation measurements have to be carried out under an equally broad spectrum of environmental conditions. This report is one of a series intended to give information on the performance characteristics of radiological protection instruments, to assist in the selection of appropriate instruments for a given purpose, to interpret the results obtained with such instruments, and, in particular, to know the likely sources and magnitude of errors that might be associated with measurements in the field. The radiation, electrical and environmental characteristics of radiation protection instruments are considered together with those aspects of the construction which make an instrument convenient for routine use. To provide consistent criteria for instrument performance, the range of tests performed on any particular class of instrument, the test methods and the criteria of acceptable performance are based broadly on the a...

  1. Observations of 50/60 Hz Power Line Radiation in the Low Latitude Ionosphere Detected by the Electric Field Instrument on the C/NOFS Satellite

    Science.gov (United States)

    Pfaff, R. F., Jr.; Freudenreich, H. T.; Simoes, F. A.; Liebrecht, M. C.; Farrell, W.

    2017-12-01

    One of the most ubiquitous forms of EM radiation emanating from the earth's surface is that of power line radiation. Associated with AC electric power generation, such emissions are typically launched along conducting power lines that may travel hundreds, or even thousands of km, from generating stations. The fundamental frequencies of such emissions are characteristically 50 Hz or 60 Hz, depending on the regional standards for power generation/consumption. The frequency of this radiation is well below that of the plasma frequency of the ionosphere (typically several MHz) and hence is expected to reflect back to the earth and propagate in the waveguide formed by the earth's surface and the bottom ledge of the ionosphere, typically near 100 km. Given that such power lines are widespread on the exposed lithosphere, the leakage of some ELF emissions associated with electric power generation might nevertheless be expected in the ionosphere, in the same manner in which a small fraction of the power associated with ELF Schumann resonances and lightning sferics have been shown to penetrate into the ionosphere. We present direct measurements of 50/60 Hz power line radiation detected by in situ probes on an orbiting satellite in the earth's ionosphere. The data were gathered by the Vector Electric Field Investigation (VEFI) tri-axial double probe detector flown on the Communication/Navigation Outage Forecast System (C/NOFS) satellite. C/NOFS was launched in April, 2008 into a low latitude (13 deg inclination) orbit with perigee and apogee of 400 km and 850 km, respectively. The electric field wave data were gathered by ELF receivers comprised of two orthogonal broadband channels sampled at 512 s/sec each, and digitized with 16 bit A/D converters. The data show distinct 60 Hz emissions while the satellite sampled within the Brazilian sector whereas distinct 50 Hz emissions were detected over India. Other, less distinct, emissions were observed over Africa and southeast Asia

  2. Radiation detection and measurement

    International Nuclear Information System (INIS)

    Knoll, G.F.

    1979-01-01

    Introductory material covers radiation sources, radiation interactions, general properties of radiation detectors, and counting statistics and error prediction. This is followed by detailed sections on gas-filled detectors, scintillation counters, semiconductor detectors, neutron detectors and spectroscopy, detector electronics and pulse processing, and miscellaneous radiation detectors and applications

  3. A damage detection method for instrumented civil structures using prerecorded Green’s functions and cross-correlation

    OpenAIRE

    Heckman, Vanessa; Kohler, Monica; Heaton, Thomas

    2011-01-01

    Automated damage detection methods have application to instrumented structures that are susceptible to types of damage that are difficult or costly to detect. The presented method has application to the detection of brittle fracture of welded beam-column connections in steel moment-resisting frames (MRFs), where locations of potential structural damage are known a priori. The method makes use of a prerecorded catalog of Green’s function templates and a cross-correlation method ...

  4. SMM detection of diffuse Galactic 511 keV annihilation radiation

    Science.gov (United States)

    Share, G. H.; Kinzer, R. L.; Kurfess, J. D.; Messina, D. C.; Purcell, W. R.

    1988-01-01

    Observations of the 511 keV annihilation line from the vicinity of the Galactic center from October to February for 1980/1981, 1981/1982, 1982/1983, 1984/1985, and 1985/1986 are presented. The measurements were made with the gamma-ray spectrometer on the SMM. The design of the instrument and some of its properties used in the analysis are described, and the methods used for accumulating, fitting, and analyzing the data are outlined. It is shown how the Galactic 511 keV line was separated from the intense and variable background observed in orbit. The SMM observations are compared with previous measurements of annihilation radiation from the Galactic center region, and the astrophysical implications are discussed. It is argued that most of the measurements made to date suggest the presence of an extended Galactic source of annihilation radiation.

  5. The calibration procedure of the radiation monitoring system installed in radiation controlled area of KOMAC

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sung-Kyun; Min, Yi-Sub; Park, Jeong-Min; Cho, Yong-Sub [Korea Atomic Energy Research Institute, Gyeongju (Korea, Republic of)

    2016-10-15

    The spaces, where these accelerators are installed, are defined as the radiation controlled area and the levels of the radiation in this area are monitored by the radiation monitoring system (RMS) to protect radiation workers and experiment users from the hazards of the ionizing radiation and the surface and air contamination tests are carried out periodically by the radiation secure team. The most of RMS instruments are installed in the accelerator building, where the 100-MeV proton linear accelerator is installed. All detectors of RMS should be calibrated every year to prove the reliability of RMS and almost all instruments for RMS was calibrated during this summer maintenance period of KOMAC this year. Almost all RMS instruments installed in KOMAC is calibrated between 2016-07-13 and 2016-08-24. As the calibration result, if the current reading value are within the 5% of the reference dose rate value, this RMS instrument can be used one more year. Otherwise, the detector of that RMS instrument should be repaired or replaced. The self-calibration certificate for each RMS instrument will be published only for the instrument to satisfy the condition.

  6. Which Instruments can Detect Submaximal Physical and Functional Capacity in Patients With Chronic Nonspecific Back Pain?: A Systematic Review

    NARCIS (Netherlands)

    van der Meer, Suzan; Trippolini, Maurizio A.; van der Palen, Jacobus Adrianus Maria; Verhoeven, Jan; Reneman, Michiel F.

    2013-01-01

    Objective. To evaluate the validity of instruments that claim to detect submaximal capacity when maximal capacity is requested in patients with chronic nonspecific musculoskeletal pain. Summary of Background Data. Several instruments have been developed to measure capacity in patients with chronic

  7. Which Instruments Can Detect Submaximal Physical and Functional Capacity in Patients With Chronic Nonspecific Back Pain? A Systematic Review

    NARCIS (Netherlands)

    van der Meer, Suzan; Trippolini, Maurizio A.; van der Palen, Job; Verhoeven, Jan; Reneman, Michiel F.

    2013-01-01

    Study Design. Systematic review. Objective. To evaluate the validity of instruments that claim to detect submaximal capacity when maximal capacity is requested in patients with chronic nonspecific musculoskeletal pain. Summary of Background Data. Several instruments have been developed to measure

  8. Neutron and synchrotron radiation for condensed matter studies. Volume 1: theory, instruments and methods

    International Nuclear Information System (INIS)

    Baruchel, J.; Hodeau, J.L.; Lehmann, M.S.; Regnard, J.R.; Schlenker, C.

    1993-01-01

    This book provides the basic information required by a research scientist wishing to undertake studies using neutrons or synchrotron radiation at a Large Facility. These lecture notes result from 'HERCULES', a course that has been held in Grenoble since 1991 to train young scientists in these fields. They cover the production of neutrons and synchrotron radiation and describe all aspects of instrumentation. In addition, this work outlines the basics of the various fields of research pursued at these Large Facilities. It consists of a series of chapters written by experts in the particular fields. While following a progression and constituting a lecture course on neutron and x-ray scattering, these chapters can also be read independently. This first volume will be followed by two further volumes concerned with the applications to solid state physics and chemistry, and to biology and soft condensed matter properties

  9. Optimal Background Attenuation for Fielded Radiation Detection Systems

    International Nuclear Information System (INIS)

    Robinson, Sean M.; Kaye, William R.; Schweppe, John E.; Siciliano, Edward R.

    2006-01-01

    Radiation detectors are often placed in positions difficult to shield from the effects of terrestrial background. This is particularly true in the case of Radiation Portal Monitor (RPM) systems, as their wide viewing angle and outdoor installations make them susceptible to terrestrial background from the surrounding area. A low background is desired in most cases, especially when the background noise is of comparable strength to the signal of interest. The problem of shielding a generalized RPM from terrestrial background is considered. Various detector and shielding scenarios are modeled with the Monte-Carlo N Particle (MCNP) computer code. Amounts of nominal-density shielding needed to attenuate the terrestrial background to varying degrees are given, along with optimal shielding geometry to be used in areas where natural shielding is limited, and where radiation detection must occur in the presence of natural background. Common shielding solutions such as steel plating are evaluated based on the signal to noise ratio and the benefits are weighed against the incremental cost.

  10. A Portable Array-Type Optical Fiber Sensing Instrument for Real-Time Gas Detection

    Directory of Open Access Journals (Sweden)

    San-Shan Hung

    2016-12-01

    Full Text Available A novel optical fiber array-type of sensing instrument with temperature compensation for real-time detection was developed to measure oxygen, carbon dioxide, and ammonia simultaneously. The proposed instrument is multi-sensing array integrated with real-time measurement module for portable applications. The sensing optical fibers were etched and polished before coating to increase sensitivities. The ammonia and temperature sensors were each composed of a dye-coated single-mode fiber with constructing a fiber Bragg grating and a long-period filter grating for detecting light intensity. Both carbon dioxide and oxygen sensing structures use multimode fibers where 1-hydroxy-3,6,8-pyrene trisulfonic acid trisodium salt is coated for carbon dioxide sensing and Tris(2,2′-bipyridyl dichlororuthenium(II hexahydrate and Tris(bipyridineruthenium(II chloride are coated for oxygen sensing. Gas-induced fluorescent light intensity variation was applied to detect gas concentration. The portable gas sensing array was set up by integrating with photo-electronic measurement modules and a human-machine interface to detect gases in real time. The measured data have been processed using piecewise-linear method. The sensitivity of the oxygen sensor were 1.54%/V and 9.62%/V for concentrations less than 1.5% and for concentrations between 1.5% and 6%, respectively. The sensitivity of the carbon dioxide sensor were 8.33%/V and 9.62%/V for concentrations less than 2% and for concentrations between 2% and 5%, respectively. For the ammonia sensor, the sensitivity was 27.78%/V, while ammonia concentration was less than 2%.

  11. A Portable Array-Type Optical Fiber Sensing Instrument for Real-Time Gas Detection.

    Science.gov (United States)

    Hung, San-Shan; Chang, Hsing-Cheng; Chang, I-Nan

    2016-12-08

    A novel optical fiber array-type of sensing instrument with temperature compensation for real-time detection was developed to measure oxygen, carbon dioxide, and ammonia simultaneously. The proposed instrument is multi-sensing array integrated with real-time measurement module for portable applications. The sensing optical fibers were etched and polished before coating to increase sensitivities. The ammonia and temperature sensors were each composed of a dye-coated single-mode fiber with constructing a fiber Bragg grating and a long-period filter grating for detecting light intensity. Both carbon dioxide and oxygen sensing structures use multimode fibers where 1-hydroxy-3,6,8-pyrene trisulfonic acid trisodium salt is coated for carbon dioxide sensing and Tris(2,2'-bipyridyl) dichlororuthenium(II) hexahydrate and Tris(bipyridine)ruthenium(II) chloride are coated for oxygen sensing. Gas-induced fluorescent light intensity variation was applied to detect gas concentration. The portable gas sensing array was set up by integrating with photo-electronic measurement modules and a human-machine interface to detect gases in real time. The measured data have been processed using piecewise-linear method. The sensitivity of the oxygen sensor were 1.54%/V and 9.62%/V for concentrations less than 1.5% and for concentrations between 1.5% and 6%, respectively. The sensitivity of the carbon dioxide sensor were 8.33%/V and 9.62%/V for concentrations less than 2% and for concentrations between 2% and 5%, respectively. For the ammonia sensor, the sensitivity was 27.78%/V, while ammonia concentration was less than 2%.

  12. MRI-alone radiation therapy planning for prostate cancer: Automatic fiducial marker detection

    International Nuclear Information System (INIS)

    Ghose, Soumya; Mitra, Jhimli; Rivest-Hénault, David; Fazlollahi, Amir; Fripp, Jurgen; Dowling, Jason A.; Stanwell, Peter; Pichler, Peter; Sun, Jidi; Greer, Peter B.

    2016-01-01

    Purpose: The feasibility of radiation therapy treatment planning using substitute computed tomography (sCT) generated from magnetic resonance images (MRIs) has been demonstrated by a number of research groups. One challenge with an MRI-alone workflow is the accurate identification of intraprostatic gold fiducial markers, which are frequently used for prostate localization prior to each dose delivery fraction. This paper investigates a template-matching approach for the detection of these seeds in MRI. Methods: Two different gradient echo T1 and T2* weighted MRI sequences were acquired from fifteen prostate cancer patients and evaluated for seed detection. For training, seed templates from manual contours were selected in a spectral clustering manifold learning framework. This aids in clustering “similar” gold fiducial markers together. The marker with the minimum distance to a cluster centroid was selected as the representative template of that cluster during training. During testing, Gaussian mixture modeling followed by a Markovian model was used in automatic detection of the probable candidates. The probable candidates were rigidly registered to the templates identified from spectral clustering, and a similarity metric is computed for ranking and detection. Results: A fiducial detection accuracy of 95% was obtained compared to manual observations. Expert radiation therapist observers were able to correctly identify all three implanted seeds on 11 of the 15 scans (the proposed method correctly identified all seeds on 10 of the 15). Conclusions: An novel automatic framework for gold fiducial marker detection in MRI is proposed and evaluated with detection accuracies comparable to manual detection. When radiation therapists are unable to determine the seed location in MRI, they refer back to the planning CT (only available in the existing clinical framework); similarly, an automatic quality control is built into the automatic software to ensure that all gold

  13. MRI-alone radiation therapy planning for prostate cancer: Automatic fiducial marker detection

    Energy Technology Data Exchange (ETDEWEB)

    Ghose, Soumya, E-mail: soumya.ghose@case.edu; Mitra, Jhimli [Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio 44106 and CSIRO Health and Biosecurity, The Australian e-Health & Research Centre, Herston, QLD 4029 (Australia); Rivest-Hénault, David; Fazlollahi, Amir; Fripp, Jurgen; Dowling, Jason A. [CSIRO Health and Biosecurity, The Australian e-Health & Research Centre, Herston, QLD 4029 (Australia); Stanwell, Peter [School of health sciences, The University of Newcastle, Newcastle, NSW 2308 (Australia); Pichler, Peter [Department of Radiation Oncology, Cavalry Mater Newcastle Hospital, Newcastle, NSW 2298 (Australia); Sun, Jidi; Greer, Peter B. [School of Mathematical and Physical Sciences, The University of Newcastle, Newcastle, NSW 2308, Australia and Department of Radiation Oncology, Cavalry Mater Newcastle Hospital, Newcastle, NSW 2298 (Australia)

    2016-05-15

    Purpose: The feasibility of radiation therapy treatment planning using substitute computed tomography (sCT) generated from magnetic resonance images (MRIs) has been demonstrated by a number of research groups. One challenge with an MRI-alone workflow is the accurate identification of intraprostatic gold fiducial markers, which are frequently used for prostate localization prior to each dose delivery fraction. This paper investigates a template-matching approach for the detection of these seeds in MRI. Methods: Two different gradient echo T1 and T2* weighted MRI sequences were acquired from fifteen prostate cancer patients and evaluated for seed detection. For training, seed templates from manual contours were selected in a spectral clustering manifold learning framework. This aids in clustering “similar” gold fiducial markers together. The marker with the minimum distance to a cluster centroid was selected as the representative template of that cluster during training. During testing, Gaussian mixture modeling followed by a Markovian model was used in automatic detection of the probable candidates. The probable candidates were rigidly registered to the templates identified from spectral clustering, and a similarity metric is computed for ranking and detection. Results: A fiducial detection accuracy of 95% was obtained compared to manual observations. Expert radiation therapist observers were able to correctly identify all three implanted seeds on 11 of the 15 scans (the proposed method correctly identified all seeds on 10 of the 15). Conclusions: An novel automatic framework for gold fiducial marker detection in MRI is proposed and evaluated with detection accuracies comparable to manual detection. When radiation therapists are unable to determine the seed location in MRI, they refer back to the planning CT (only available in the existing clinical framework); similarly, an automatic quality control is built into the automatic software to ensure that all gold

  14. Calculation of the detection limit in radiation measurements with systematic uncertainties

    International Nuclear Information System (INIS)

    Kirkpatrick, J.M.; Russ, W.; Venkataraman, R.; Young, B.M.

    2015-01-01

    The detection limit (L D ) or Minimum Detectable Activity (MDA) is an a priori evaluation of assay sensitivity intended to quantify the suitability of an instrument or measurement arrangement for the needs of a given application. Traditional approaches as pioneered by Currie rely on Gaussian approximations to yield simple, closed-form solutions, and neglect the effects of systematic uncertainties in the instrument calibration. These approximations are applicable over a wide range of applications, but are of limited use in low-count applications, when high confidence values are required, or when systematic uncertainties are significant. One proposed modification to the Currie formulation attempts account for systematic uncertainties within a Gaussian framework. We have previously shown that this approach results in an approximation formula that works best only for small values of the relative systematic uncertainty, for which the modification of Currie's method is the least necessary, and that it significantly overestimates the detection limit or gives infinite or otherwise non-physical results for larger systematic uncertainties where such a correction would be the most useful. We have developed an alternative approach for calculating detection limits based on realistic statistical modeling of the counting distributions which accurately represents statistical and systematic uncertainties. Instead of a closed form solution, numerical and iterative methods are used to evaluate the result. Accurate detection limits can be obtained by this method for the general case

  15. Limit of detection in the presence of instrumental and non-instrumental errors: study of the possible sources of error and application to the analysis of 41 elements at trace levels by inductively coupled plasma-mass spectrometry technique

    International Nuclear Information System (INIS)

    Badocco, Denis; Lavagnini, Irma; Mondin, Andrea; Tapparo, Andrea; Pastore, Paolo

    2015-01-01

    In this paper the detection limit was estimated when signals were affected by two error contributions, namely instrumental errors and operational-non-instrumental errors. The detection limit was theoretically obtained following the hypothesis testing schema implemented with the calibration curve methodology. The experimental calibration design was based on J standards measured I times with non-instrumental errors affecting each standard systematically but randomly among the J levels. A two-component variance regression was performed to determine the calibration curve and to define the detection limit in these conditions. The detection limit values obtained from the calibration at trace levels of 41 elements by ICP-MS resulted larger than those obtainable from a one component variance regression. The role of the reagent impurities on the instrumental errors was ascertained and taken into account. Environmental pollution was studied as source of non-instrumental errors. The environmental pollution role was evaluated by Principal Component Analysis technique (PCA) applied to a series of nine calibrations performed in fourteen months. The influence of the seasonality of the environmental pollution on the detection limit was evidenced for many elements usually present in the urban air particulate. The obtained results clearly indicated the need of using the two-component variance regression approach for the calibration of all the elements usually present in the environment at significant concentration levels. - Highlights: • Limit of detection was obtained considering a two variance component regression. • Calibration data may be affected by instrumental and operational conditions errors. • Calibration model was applied to determine 41 elements at trace level by ICP-MS. • Non instrumental errors were evidenced by PCA analysis

  16. Magnetic Measuring Instrumentation with Radiation-Resistant Hall Sensors for Fusion Reactors: Experience of Testing at JET

    Czech Academy of Sciences Publication Activity Database

    Bolshakova, I.; Quercia, A.; Coccorese, V.; Murari, A.; Holyaka, R.; Ďuran, Ivan; Viererbl, L.; Konopleva, R.; Yerashok, V.

    2012-01-01

    Roč. 59, č. 4 (2012), s. 1224-1231 ISSN 0018-9499. [International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and their Applications. Ghent, 06.06.2011-09.06.2011] R&D Projects: GA ČR GAP205/10/2055 Institutional research plan: CEZ:AV0Z20430508 Keywords : plasma * tokamak * JET * Hall probes * radiation resistance Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.219, year: 2012

  17. Optimization of biological and instrumental detection of explosives and ignitable liquid residues including canines, SPME/ITMS and GC/MSn

    Science.gov (United States)

    Furton, Kenneth G.; Harper, Ross J.; Perr, Jeannette M.; Almirall, Jose R.

    2003-09-01

    A comprehensive study and comparison is underway using biological detectors and instrumental methods for the rapid detection of ignitable liquid residues (ILR) and high explosives. Headspace solid phase microextraction (SPME) has been demonstrated to be an effective sampling method helping to identify active odor signature chemicals used by detector dogs to locate forensic specimens as well as a rapid pre-concentration technique prior to instrumental detection. Common ignitable liquids and common military and industrial explosives have been studied including trinitrotoluene, tetryl, RDX, HMX, EGDN, PETN and nitroglycerine. This study focuses on identifying volatile odor signature chemicals present, which can be used to enhance the level and reliability of detection of ILR and explosives by canines and instrumental methods. While most instrumental methods currently in use focus on particles and on parent organic compounds, which are often involatile, characteristic volatile organics are generally also present and can be exploited to enhance detection particularly for well-concealed devices. Specific examples include the volatile odor chemicals 2-ethyl-1-hexanol and cyclohexanone, which are readily available in the headspace of the high explosive composition C-4; whereas, the active chemical cyclo-1,3,5-trimethylene-2,4,6-trinitramine (RDX) is not. The analysis and identification of these headspace 'fingerprint' organics is followed by double-blind dog trials of the individual components using certified teams in an attempt to isolate and understand the target compounds to which dogs are sensitive. Studies to compare commonly used training aids with the actual target explosive have also been undertaken to determine their suitability and effectiveness. The optimization of solid phase microextraction (SPME) combined with ion trap mobility spectrometry (ITMS) and gas chromatography/mass spectrometry/mass spectrometry (GC/MSn) is detailed including interface development

  18. Sensor and method for measurment of select components of a material based on detection of radiation after interaction with the material

    International Nuclear Information System (INIS)

    Chase, L.M.; Anderson, L.M.; Norton, M.K.

    1993-01-01

    A sensor is described for measuring one or more select components of a sheet, comprising: a radiation source for emitting radiation toward the sheet; a plurality of detecting means, wherein at least one detecting means is offset from the source, for detecting radiation after interaction with the sheet; means for directing the radiation so that the radiation makes multiple interactions with the sheet in moving from the source to the detecting means, wherein the directing means includes a first reflector and second reflector defining a sheet space for the sheet to occupy; means for computing a ratio of the intensity of the detected radiation when the sheet is absent from the sheet space and the intensity of the detected radiation when the sheet occupies the sheet space; and means for computing the absorption power of the sheet from the intensity of the detected radiation

  19. Detection limits of nuclear radiation and radioactivity measurements. Digital, non-selective measurements on untreated specimens. Draft. Nachweisgrenzen bei Kernstrahlungs- und Radioaktivitaetsmessungen. Digitale, nichtselektive Messungen ohne Probenbehandlung. Entwurf

    Energy Technology Data Exchange (ETDEWEB)

    1985-01-01

    The standard applies to nuclear radiation measurements where the number of pulses is recorded directly, considering exclusively the statistical character of radioactive decay and pulse counting, with the measuring time being short with regard to the half-life of radionuclides, and instrument dead-times being neglectible. The standard is intended to define suitable characteristics allowing an evaluation of detection efficiency. Two criteria are explained for given error probabilities: the sensitivity limit which allows a decision to be made as to whether the pulses recorded include values contributed by the sample; the detection limit which permits an evaluation of the measuring method in terms of suitability to the measuring goals. (orig./HP).

  20. Nuclear radiation detection by a variband semiconductor

    International Nuclear Information System (INIS)

    Volkov, A.S.

    1981-01-01

    Possibilities of using a variband semiconductor for detecting nuclear radiations are considered. It is shown that the variaband quasielectric field effectively collects charges induced by a nuclear particle only at a small mean free path in the semiconductor (up to 100 μm), the luminescence spectrum of the variband semiconductor when a nuclear particle gets into it, in principle, permits to determine both the energy and mean free path in the semiconductor (even at large mean free paths) [ru

  1. Current trends in gamma radiation detection for radiological emergency response

    Science.gov (United States)

    Mukhopadhyay, Sanjoy; Guss, Paul; Maurer, Richard

    2011-09-01

    Passive and active detection of gamma rays from shielded radioactive materials, including special nuclear materials, is an important task for any radiological emergency response organization. This article reports on the current trends and status of gamma radiation detection objectives and measurement techniques as applied to nonproliferation and radiological emergencies. In recent years, since the establishment of the Domestic Nuclear Detection Office by the Department of Homeland Security, a tremendous amount of progress has been made in detection materials (scintillators, semiconductors), imaging techniques (Compton imaging, use of active masking and hybrid imaging), data acquisition systems with digital signal processing, field programmable gate arrays and embedded isotopic analysis software (viz. gamma detector response and analysis software [GADRAS]1), fast template matching, and data fusion (merging radiological data with geo-referenced maps, digital imagery to provide better situational awareness). In this stride to progress, a significant amount of inter-disciplinary research and development has taken place-techniques and spin-offs from medical science (such as x-ray radiography and tomography), materials engineering (systematic planned studies on scintillators to optimize several qualities of a good scintillator, nanoparticle applications, quantum dots, and photonic crystals, just to name a few). No trend analysis of radiation detection systems would be complete without mentioning the unprecedented strategic position taken by the National Nuclear Security Administration (NNSA) to deter, detect, and interdict illicit trafficking in nuclear and other radioactive materials across international borders and through the global maritime transportation-the so-called second line of defense.

  2. Astrobiology Sample Analysis Program (ASAP) for Advanced Life Detection Instrumentation Development and Calibration

    Science.gov (United States)

    Glavin, Daniel; Brinkerhoff, Will; Dworkin, Jason; Eigenbrode, Jennifer; Franz, Heather; Mahaffy, Paul; Stern, Jen; Blake, Daid; Sandford, Scott; Fries, marc; hide

    2008-01-01

    Scientific ground-truth measurements for near-term Mars missions, such as the 2009 Mars Science Laboratory (MSL) mission, are essential for validating current in situ flight instrumentation and for the development of advanced instrumentation technologies for life-detection missions over the next decade. The NASA Astrobiology Institute (NAI) has recently funded a consortium of researchers called the Astrobiology Sample Analysis Program (ASAP) to analyze an identical set of homogenized martian analog materials in a "round-robin" style using both state-of-the-art laboratory techniques as well as in-situ flight instrumentation including the SAM gas chromatograph mass spectrometer and CHEMIN X-ray diffraction/fluorescence instruments on MSL and the Urey and MOMA organic analyzer instruments under development for the 2013 ExoMars missions. The analog samples studied included an Atacama Desert soil from Chile, the Murchison meteorite, a gypsum sample from the 2007 AMASE Mars analog site, jarosite from Panoche Valley, CA, a hydrothermal sample from Rio Tinto, Spain, and a "blind" sample collected during the 2007 MSL slow-motion field test in New Mexico. Each sample was distributed to the team for analysis to: (1) determine the nature and inventory of organic compounds, (2) measure the bulk carbon and nitrogen isotopic composition, (3) investigate elemental abundances, mineralogy and matrix, and (4) search for biological activity. The experimental results obtained from the ASAP Mars analog research consortium will be used to build a framework for understanding the biogeochemistry of martian analogs, help calibrate current spaceflight instrumentation, and enhance the scientific return from upcoming missions.

  3. Multi-channel integrated circuits for the detection and measurement of ionizing radiation

    International Nuclear Information System (INIS)

    Engel, G.L.; Duggireddi, N.; Vangapally, V.; Elson, J.M.; Sobotka, L.G.; Charity, R.J.

    2011-01-01

    The Integrated Circuits (IC) Design Research Laboratory at Southern Illinois University Edwardsville (SIUE) has collaborated with the Nuclear Reactions Group at Washington University (WU) to develop a family of multi-channel integrated circuits. To date, the collaboration has successfully produced two micro-chips. The first was an analog shaped and peak sensing chip with on-board constant-fraction discriminators and sparsified readout. This chip is known as Heavy-Ion Nuclear Physics-16 Channel (HINP16C). The second chip, christened PSD8C, was designed to logically complement (in terms of detector types) the HINP16C chip. Pulse Shape Discrimination-8 Channel (PSD8C), featuring three settable charge integration windows per channel, performs pulse shape discrimination (PSD). This paper summarizes the design, capabilities, and features of the HINP16C and PSD8C ICs. It proceeds to discuss the modifications, made to the ICs and their associated systems, which have attempted to improve ease of use, increase performance, and extend capabilities. The paper concludes with a brief discussion of what may be the next chip (employing a multi-sampling scheme) to be added to our CMOS ASIC 'tool box' for radiation detection instrumentation.

  4. System and method for extracting physiological information from remotely detected electromagnetic radiation

    NARCIS (Netherlands)

    2016-01-01

    The present invention relates to a device and a method for extracting physiological information indicative of at least one health symptom from remotely detected electromagnetic radiation. The device comprises an interface (20) for receiving a data stream comprising remotely detected image data

  5. System and method for extracting physiological information from remotely detected electromagnetic radiation

    NARCIS (Netherlands)

    2015-01-01

    The present invention relates to a device and a method for extracting physiological information indicative of at least one health symptom from remotely detected electromagnetic radiation. The device comprises an interface (20) for receiving a data stream comprising remotely detected image data

  6. Detecting solar chameleons through radiation pressure

    CERN Document Server

    Baum, S.; Hoffmann, D.H.H.; Karuza, M.; Semertzidis, Y.K.; Upadhye, A.; Zioutas, K.

    2014-10-24

    Light scalar fields can drive the accelerated expansion of the universe. Hence, they are obvious dark energy candidates. To make such models compatible with tests of General Relativity in the solar system and "fifth force" searches on Earth, one needs to screen them. One possibility is the so-called "chameleon" mechanism, which renders an effective mass depending on the local matter density. If chameleon particles exist, they can be produced in the sun and detected on earth exploiting the equivalent of a radiation pressure. Since their effective mass scales with the local matter density, chameleons can be reflected by a dense medium if their effective mass becomes greater than their total energy. Thus, under appropriate conditions, a flux of solar chameleons may be sensed by detecting the total instantaneous momentum transferred to a suitable opto-mechanical force/pressure sensor. We calculate the solar chameleon spectrum and the reach in the chameleon parameter space of an experiment using the preliminary re...

  7. Detection of a stochastic background of gravitational radiation by the Doppler tracking of spacecraft

    International Nuclear Information System (INIS)

    Mashhoon, B.; Grishchuk, L.P.

    1980-01-01

    The possibility of detection of an isotropic background gravitational radiation of a stochastic nature by the method of Doppler tracking of spacecraft is considered. In the geometrical optics limit, the general formula for the frequency shift of an electromagnetic signal in the gravitational radiation field is discussed, and it is shown to be gauge (or rather Lie) independent. A detailed examination of the propagation of a free electromagnetic wave in a gravitational radiation field shows that no resonance phenomena can be expected. Thus, the results valid in the geometrical optics limit are also approximately valid for any gravitational radiation spectrum dominated by wavelengths large compared to that of the electromagnetic signal. The ''Doppler noise'' due to a stochastic background is evaluated, and it is shown to depend on the total energy density of the background and a parameter that is a characteristic of the aradiation spectrum and the detection system used. A background gravitational radiation with an energy density comparable to the electromagnetic (approx.3 K) background and a spectrum dominated by wavelengths > or approx. =1 AU may be detectable in the near future by the Doppler tracking of interplanetary spacecraft

  8. Technological considerations in emergency instrument preparedness

    International Nuclear Information System (INIS)

    Selby, J.M.

    1975-01-01

    The types of emergency instrumentation systems necessary to characterize the severity and extent of radiation accidents and to aid in the protection of operating personnel and personnel living near the plant are discussed. These include instruments for direct measurement of the airborne radioactive material within the facility, fixed instrumentation for ambient dose rate monitoring or area monitoring, and portable instruments for environmental monitoring

  9. Problems with radiological surveillance instrumentation

    International Nuclear Information System (INIS)

    Swinth, K.L.; Tanner, J.E.; Fleming, D.M.

    1984-09-01

    Many radiological surveillance instruments are in use at DOE facilities throughout the country. These instruments are an essential part of all health physics programs, and poor instrument performance can increase program costs or compromise program effectiveness. Generic data from simple tests on newly purchased instruments shows that many instruments will not meet requirements due to manufacturing defects. In other cases, lack of consideration of instrument use has resulted in poor acceptance of instruments and poor reliability. The performance of instruments is highly variable for electronic and mechanical performance, radiation response, susceptibility to interferences and response to environmental factors. Poor instrument performance in these areas can lead to errors or poor accuracy in measurements

  10. Problems with radiological surveillance instrumentation

    International Nuclear Information System (INIS)

    Swinth, K.L.; Tanner, J.E.; Fleming, D.M.

    1985-01-01

    Many radiological surveillance instruments are in use at DOE facilities throughout the country. These instruments are an essential part of all health physics programs, and poor instrument performance can increase program costs or compromise program effectiveness. Generic data from simple tests on newly purchased instruments shows that many instruments will not meet requirements due to manufacturing defects. In other cases, lack of consideration of instrument use has resulted in poor acceptance of instruments and poor reliability. The performance of instruments is highly variable for electronic and mechanical performance, radiation response, susceptibility to interferences and response to environmental factors. Poor instrument performance in these areas can lead to errors or poor accuracy in measurements

  11. Characteristics of X ray calibration fields for performance test of radiation measuring instruments

    International Nuclear Information System (INIS)

    Shimizu, Shigeru; Takahashi, Fumiaki; Sawahata, Tadahiro; Tohnami, Kohichi; Kikuchi, Hiroshi; Murayama, Takashi

    1999-02-01

    Performance test and calibration of the radiation measuring instruments for low energy photons are made using the X ray calibration fields which are monochromatically characterized by filtration of continuous X ray spectrum. The X ray calibration field needs to be characterized by some quality conditions such as quality index and homogeneity coefficient. The present report describes quality conditions, spectrum and some characteristics of X ray irradiation fields in the Facility of Radiation Standard of the Japan Atomic Energy Research Institute (FRS-JAERI). Fifty nine X ray qualities with the quality index of 0.6, 0.7, 0.8 and 0.9 were set for the tube voltages between 10 kV and 350 kV. Estimation of X ray spectrum measured with a Ge detector was made in terms of exposure, ambient dose equivalent and fluence for all the obtained qualities. Practical irradiation field was determined as the dose distribution uniformity is within ±3%. The obtained results improve the quality of X ray calibration fields and calibration accuracy. (author)

  12. Radiation detection with Nb/Al-AlOx/Al/Nb superconducting tunnel junctions

    International Nuclear Information System (INIS)

    Matsumura, Atsuki; Takahashi, Toru; Kurakado, Masahiko

    1992-01-01

    Superconductor radiation detectors have the possibility of 20-30 times better energy resolution than that of a high resolution Si detector. We fabricated Nb/Al-AlOx/Al/Nb superconducting tunnel junctions with low leakage current. X rays were detected with large area junctions of 178x178 μm 2 . High energy resolution of 160 eV for 5.9 keV was obtained. We also fabricated series connected junctions which covers a rather large area of 4x4 mm 2 . α particles injected into the rear substrate were detected using nonthermal phonons induced by the radiations in the substrate. (author)

  13. Radiation portal evaluation parameters

    International Nuclear Information System (INIS)

    York, R.L.

    1998-01-01

    The detection of the unauthorized movement of radioactive materials is one of the most effective nonproliferation measures. Automatic special nuclear material (SNM) portal monitors are designed to detect this unauthorized movement and are an important part of the safeguard systems at US nuclear facilities. SNM portals differ from contamination monitors because they are designed to have high sensitivity for the low energy gamma-rays associated with highly enriched uranium (HEU) and plutonium. These instruments are now being installed at international borders to prevent the spread of radioactive contamination an SNM. In this paper the parameters important to evaluating radiation portal monitors are discussed. (author)

  14. Simulation and Performance Test Technology Development for Semiconductor Radiation Detection Instrument Fabrication

    International Nuclear Information System (INIS)

    Kim, Jong Kyung; Lee, W. G.; Kim, S. Y.; Shin, C. H.; Kim, K. O.; Park, J. M.; Jang, D. Y.; Kang, J. S.

    2010-06-01

    - Analysis on the Absorbed Dose and Electron Generation by Using MCNPX Code - Analysis on the Change of Measured Energy Spectrum As a Function of Bias Voltage Applied in Semiconductor Detector - Comparison of Monte Carlo Simulation Considering the Charge Collection Efficiency and Experimental Result - Development of Semiconductor Sensor Design Code Based on the Graphic User Interface - Analysis on Depth Profile of Ion-implanted Semiconductor Wafer Surface and Naturally Generated SiO2 Insulation Layer Using Auger Electron Spectroscopy - Measurement of AFM Images and Roughness to Abalyze Surface of Semiconductor Wafer with respect to Annealing and Cleaning Process - Measurement of Physical Properties for Semiconductor Detector Surface after CZT Passivation Process - Evaluation of Crystal Structure and Specific Resistance of CZT - Measurement/Analysis on Band Structure of CZT Crystal - Evaluation of Neutron Convertor Layer with respect to Change in Temperature - Measurement/Evaluation of physical characteristics for lattice parameter, specific resistance, and band structure of CZT crystal - Measurement/Evaluation of lattice transition of SiC semiconductor detector after radiation irradiation - Measurement/Evaluation of performance of semiconductor detector with respect to exposure in high temperature environment

  15. A new programmable zone dosimeter for operational monitoring and measurement of external gamma radiation

    International Nuclear Information System (INIS)

    Toledo Acosta, Rene; Arteche Diaz, Raul; Mesa Perez, Guillermo; Fernandez Llanez, Sandra; Tamayo Garcia, Jose Antonio; Alonso Villanueva, Gilberto

    2010-01-01

    The detection and the measurement of the nuclear radiations have turn into an important item in the nuclear detectors application and specifically the Geiger Muller ones. Coming from theirs high detection sensibility, robust construction and relative simplicity of the associated circuit, the Geiger Tubes are still one of the most widely used detectors in all the application areas regarding physics and nuclear investigations A new design instrument is presented to be measures the ambient dose of external (gamma) radiation since 10 mSv/h. It consists of three elements: Geiger-Muller detector, the electronic board for the acquisition and control and the application software. The instrument communicates trough a USB interface to the Personal Computer only for adjust calibration parameters. The software was developed in the C programming language using PICC4, 08 compilers. (author)

  16. On the γ-photon detection processes and the statistics of radiation

    International Nuclear Information System (INIS)

    Bertolotti, M.; Sibilia, C.

    1977-01-01

    The problem of detection of γ-photons is treated in the cases of photoelectric and Compton effects. In both cases the probability of detecting a γ-photon is found proportional to the first-order correlation function of the e.m. field. The statistical properties of the γ-radiation can therefore be determined through the methods developed in quantum optics

  17. Biochemical and Radiobiological Factors in the Early Detection of Radiation Injury in Mammals

    Energy Technology Data Exchange (ETDEWEB)

    Cole, L. J. [Life Sciences Division, Stanford Research Institute, Menlo Park, CA (United States)

    1971-03-15

    In considering the body of radiobiological knowledge upon which the present possibilities for the development of an objective quantitative laboratory procedure for early detection of radiation injury depend, it is evident that there are at least three general categories of radiation effects which are relevant to this objective: (1) Products of the enzymatic-chemical breakdown of macromolecules, and lysis of killed or dying cells from radiosensitive tissues, for example deoxypolynucleotides from lymphoid tissues and bone marrow; (2) Radiation-induced inhibition of synthesis of deoxyribonucleic acid (DNA) and/or other macromolecules, eliciting alterations in tissue and blood concentrations and pool size of metabolic intermediates in the synthesis, for example, deoxycytidine; (3) Radiation-induced alterations, suppression, or cessation of specialized cell function; of particular interest here is the immunological functions of lymphocytes, including those in the circulating blood. For rodents, the exquisite radiosensitivity of bone-marrow-stem cells as well as of lymphocytes has been precisely measured by modern cellular radiobiological techniques: the colony-forming technique of Till and McCulloch, yielding a D{sub 0} for bone-marrow cells of about 80 R; and the graft-versus-host reactivity of transplanted lymphocytes yielding a similar D{sub 0} value. In our own hands, a modified colony-formation technique for dog bone-marrow cells irradiated in.vitro and in vivo give D{sub 0} values of {approx}100 R. Thus, on the basis of radiation sensitivity and the time-relationships for interphase cell death for lymphocytes, it appears that this cell class is probably the best ''candidate'' source for an early radiation-injury detection system. However,- the important report by Zicha and Buric indicates that extrapolation of biochemical data on radiation dosimetry from rodents to man is not necessarily feasible, at least in the. case of the urinary excretion of deoxycytidine

  18. Integrating Nephelometer Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Uin, J. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-03-01

    The Integrating Nephelometer (Figure 1) is an instrument that measures aerosol light scattering. It measures aerosol optical scattering properties by detecting (with a wide angular integration – from 7 to 170°) the light scattered by the aerosol and subtracting the light scattered by the carrier gas, the instrument walls and the background noise in the detector (zeroing). Zeroing is typically performed for 5 minutes every day at midnight UTC. The scattered light is split into red (700 nm), green (550 nm), and blue (450 nm) wavelengths and captured by three photomultiplier tubes. The instrument can measure total scatter as well as backscatter only (from 90 to 170°) (Heintzenberg and Charlson 1996; Anderson et al. 1996; Anderson and Ogren 1998; TSI 3563 2015) At ARM (Atmospheric Radiation Measurement), two identical Nephelometers are usually run in series with a sample relative humidity (RH) conditioner between them. This is possible because Nephelometer sampling is non-destructive and the sample can be passed on to another instrument. The sample RH conditioner scans through multiple RH values in cycles, treating the sample. This kind of setup allows to study how aerosol particles’ light scattering properties are affected by humidification (Anderson et al. 1996). For historical reasons, the two Nephelometers in this setup are labeled “wet” and “dry”, with the “dry” Nephelometer usually being the one before the conditioner and sampling ambient air (the names are switched for the MAOS measurement site due to the high RH of the ambient air).

  19. Geiger-mueller radiation detector with means for detecting and indicating the existence of radiation overload

    International Nuclear Information System (INIS)

    Kovacs, T.; Mills, A.P.; Pfeiffer, L.N.

    1981-01-01

    When subjected to radiation overload existing geiger-mueller counters may give an erroneously low reading, resulting in possible hazard to personnel. The instant invention discloses simple and inexpensive apparatus to remedy this dangerous shortcoming. Depending on the geometry of the detector tube, two possible failure modes have been identified, and circuitry is disclosed to detect the existence of these respective failure modes. The disclosed apparatus indicates the absence of an overload condition, in addition to signaling, by both visible and audible means, the existence of excessive radiation that might result in erroneously low reading of the geiger-mueller counter

  20. Method for detecting radiation dose utilizing thermoluminescent material

    International Nuclear Information System (INIS)

    Miller, S.D.; McDonald, J.C.; Eichner, F.N.; Durham, J.S.

    1992-01-01

    The amount of ionizing radiation to which a thermoluminescent material has been exposed is determined by first cooling the thermoluminescent material and then optically stimulating the thermoluminescent material by exposure to light. Visible light emitted by the thermoluminescent material as it is allowed to warm up to room temperature is detected and counted. The thermoluminescent material may be annealed by exposure to ultraviolet light. 5 figs

  1. Near instrument-free, simple molecular device for rapid detection of herpes simplex viruses.

    Science.gov (United States)

    Lemieux, Bertrand; Li, Ying; Kong, Huimin; Tang, Yi-Wei

    2012-06-01

    The first near instrument-free, inexpensive and simple molecular diagnostic device (IsoAmp HSV, BioHelix Corp., MA, USA) recently received US FDA clearance for use in the detection of herpes simplex viruses (HSV) in genital and oral lesion specimens. The IsoAmp HSV assay uses isothermal helicase-dependent amplification in combination with a disposable, hermetically-sealed, vertical-flow strip identification. The IsoAmp HSV assay has a total test-to-result time of less than 1.5 h by omitting the time-consuming nucleic acid extraction. The diagnostic sensitivity and specificity are comparable to PCR and are superior to culture-based methods. The near instrument-free, rapid and simple characteristics of the IsoAmp HSV assay make it potentially suitable for point-of-care testing.

  2. Photon Activation Analysis Of Light Elements Using 'Non-Gamma' Radiation Spectroscopy - The Instrumental Determination Of Phosphorus

    International Nuclear Information System (INIS)

    Segebade, Christian; Goerner, Wolf

    2011-01-01

    Unlike metal determinations the analysis of light elements (e.g., carbon, oxygen, phosphorus) is frequently problematic, in particular if analysed instrumentally. In photon activation analysis (PAA) the respective activation products do not emit gamma radiation in the most cases. Usually, annihilation quanta counting and subsequent decay curve analysis have been used for determinations of C, N, O, and F. However, radiochemical separation of the respective radioisotopes mostly is indispensable. For several reasons, some of the light elements cannot be analysed following this procedure, e.g. phosphorus. In this contribution the instrumental PAA of phosphorus in organic matrix by activation with bremsstrahlung of an electron linear accelerator and subsequent beta spectroscopy is described. The accuracy of the results was excellent as obtained by analysis of a BCR Reference Material.

  3. Modelling and interpretation of gas detection using remote laser pointers.

    Science.gov (United States)

    Hodgkinson, J; van Well, B; Padgett, M; Pride, R D

    2006-04-01

    We have developed a quantitative model of the performance of laser pointer style gas leak detectors, which are based on remote detection of backscattered radiation. The model incorporates instrumental noise limits, the reflectivity of the target background surface and a mathematical description of gas leak dispersion in constant wind speed and turbulence conditions. We have investigated optimum instrument performance and limits of detection in simulated leak detection situations. We predict that the optimum height for instruments is at eye level or above, giving an operating range of 10 m or more for most background surfaces, in wind speeds of up to 2.5 ms(-1). For ground based leak sources, we find laser pointer measurements are dominated by gas concentrations over a short distance close to the target surface, making their readings intuitive to end users in most cases. This finding is consistent with the results of field trials.

  4. Radiation protection and personnel safety in industrial radiography

    International Nuclear Information System (INIS)

    Banerjee, Alok Kumar

    2015-01-01

    Due to availability of a variety of radioisotopes from BRIT, a considerable number of industrial organizations have come up in India which employ radiation sources in one form or the other. More such organizations may come up in the near future due to the 'Make in India' policy of the Government. All ionizing radiations, whether electromagnetic (gamma- ã ) or corpuscular (particles of alpha-á, or beta-â-), and neutrons (0n1) are harmful to the human body. The damage done by radiations is sinister as human senses are not capable of detecting even lethal doses of radiation. The dose of radiations absorbed by human body which take into account the biological effectiveness of different types of radiations as noted above. The overall outcome of exposure to radiation is initiated by damage to the cells of the organism. The effects of radiation may be deterministic or stochastic, early or late, of somatic or genetic type. The somatic effects (physical) can either be immediate or delayed when the whole body is acutely irradiated with radiation doses. All countries including India have brought their national laws/standards on ionizing radiation in line with the ICRP codes. The conditions for registration, transport, storage, protection and use of radiation sources have been laid down in regulations. The purpose of practical protection against radiation is to prevent any individual receiving a harmful dose. Radiation measurement Instruments like dose meter, pocket dosimeter, NaI(Tl) scintillation detector and recording instruments such as film/TLD badge have been briefly described

  5. Study of the performance of diagnostic radiology instruments during calibration

    International Nuclear Information System (INIS)

    Freitas, Rodrigo N. de; Vivolo, Vitor; Potiens, Maria da Penha A.

    2008-01-01

    Full text: The instruments used in diagnostic radiology measurements represent 8 % of the tested instruments by the calibration laboratory of IPEN annually (approximately 1600 in 2007). Considering that the calibration of this kind of instrument is performed biannually it is possible to conclude that almost 300 instruments are being used to measure the air kerma in diagnostic radiology clinics to determine the in beam values (in front of the patient), attenuated measurements (behind the patient) and scattered radiation. This work presents the results of the calibration of the instruments used in mammography, computed tomography, dental and conventional diagnostic radiology dosimetry, performed during the period of 2005 to 2007. Their performances during the calibrations measurements were evaluated. Although at the calibration laboratory there are three available series of radiation quality to this type of calibration (RQR, N and M, according to standards IEC 61267 and ISO 4037-1.), the applications can be assorted (general radiology, computed tomography, mammography, radiation protection and fluoroscopy). Depending on its design and behaviour , one kind of instrument can be used for one or more type of applications. The instruments normally used for diagnostic radiology measurements are ionization chambers with volumes varying from 3 to 1800 cm 3 , and can be cylindrical, spherical or plane parallel plates kind. They usually are sensitive to photon particles, with energies greater than 15 keV and can be used up to 1200 keV. In this work they were tested in X radiation fields from 25 to 150 kV, in specific qualities depending on the utilization of the instrument. The calibration results of 390 instruments received from 2005 to 2007 were analyzed. About 20 instruments were not able to be calibrated due to bad functioning. The calibration coefficients obtained were between 0.88 and 1.24. The uncertainties were always less than ± 3.6% to instruments used in scattered

  6. Neutron measuring instruments for radiation protection

    International Nuclear Information System (INIS)

    Heinzelmann, M.; Schneider, W.; Hoefert, M.; Kuehn, H.; Jahr, R.; Wagner, S.; Piesch, E.

    1979-09-01

    The present report deals with selected topics from the field of neutron dosimetry for radiation protection connected with the work of the subcommittee 6802 in the Standards Committee on Radiology (NAR) of the German Standards Institute (DIN). It is a sort of material collection. The topics are: 1. Measurement of the absorbed-energy dose by a) ionization chambers in fields of mixed radiation and b) recoil-proton proportional counting tubes. 2. Measurement of the equivalent dose, neutron monitors, combination methods by a) rem-meters, b) recoil-proton counting tubes, c) recombination method, tissue-equivalent proportional counters, activation methods for high energies in fields of mixed radiation, d) personnel dosimetry by means of ionization chambers and counting tubes, e) dosimetry by means of activation methods, nuclear track films, nonphotographic nuclear track detectors and solid-state dosimeters. (orig./HP) [de

  7. Detection of dark-matter-radiation of stars during visible sun eclipses

    International Nuclear Information System (INIS)

    Volkamer, Klaus

    2003-01-01

    Recently a so-far unknown form of quantized, cold dark matter was detected on a laboratory scale which shows a complementary structure as compared to known forms of matter. From the experiments results that the observed quanta of the new type of matter as integer multiples of the Planck mass (mp = n · √((h·c)/((2 · π · G))) = n 0 21.77 μg, with n = 1, 2, 3 etc.) exhibit a spatially extended 'field-like' structure ranging over distances of centimetres or more, opposite to the 'point-like' structure of the known elementary particles of the standard model. Association of quanta of the new form of 'soft' (or subtle) matter to clusters was observed, as well as re-clustering after absorption. Thus, between such quanta a physical interaction must exist. In addition, the new form of matter shows at least two interactions with normal matter, a gravitational one due to its real mass content and a so-far unknown 'topological', i.e. form-specific, interaction at phase borders. Additional indications for a weak electromagnetic interaction exist. Furthermore, the experimental results reveal that some types of quanta of the new form of 'field-like' matter exhibit positive mass, as normal matter, but others exhibit a negative mass content, both in the order of magnitude of the Planck mass. Memory effects in normal matter were detected after absorption of quanta of the new form of soft matter. In general, the findings characterize the quanta of 'fieldlike' matter as WIMP candidates of a cosmic background radiation of cold dark matter (quanta with positive mass) as well as of a cosmic background radiation of dark energy (quanta with negative mass). During visible sun eclipses in 1989, 1996 and. 1999, as well as during full moon of 6 January 2001, a so-far unknown form of dark-matter-radiation ('dark radiation') was detected. The quanta of this 'dark radiation' travel with the speed of light, but reveal macroscopic real mass, with positive and with negative mass content. The

  8. Detecting ship targets in spaceborne infrared image based on modeling radiation anomalies

    Science.gov (United States)

    Wang, Haibo; Zou, Zhengxia; Shi, Zhenwei; Li, Bo

    2017-09-01

    Using infrared imaging sensors to detect ship target in the ocean environment has many advantages compared to other sensor modalities, such as better thermal sensitivity and all-weather detection capability. We propose a new ship detection method by modeling radiation anomalies for spaceborne infrared image. The proposed method can be decomposed into two stages, where in the first stage, a test infrared image is densely divided into a set of image patches and the radiation anomaly of each patch is estimated by a Gaussian Mixture Model (GMM), and thereby target candidates are obtained from anomaly image patches. In the second stage, target candidates are further checked by a more discriminative criterion to obtain the final detection result. The main innovation of the proposed method is inspired by the biological mechanism that human eyes are sensitive to the unusual and anomalous patches among complex background. The experimental result on short wavelength infrared band (1.560 - 2.300 μm) and long wavelength infrared band (10.30 - 12.50 μm) of Landsat-8 satellite shows the proposed method achieves a desired ship detection accuracy with higher recall than other classical ship detection methods.

  9. The effects of nuclear power generators upon electronic instrumentation

    Science.gov (United States)

    Miller, C. G.; Truscello, V. C.

    1970-01-01

    Radiation sensitivity of electronic instruments susceptible to neutron and gamma radiation is evaluated by means of a radioisotope thermoelectric generator /RTG/. The gamma field of the RTG affects instrument operation and requires shielding, the neutron field does not affect operation via secondary capture-gamma production.

  10. Methods for radiation detection and characterization using a multiple detector probe

    Science.gov (United States)

    Akers, Douglas William; Roybal, Lyle Gene

    2014-11-04

    Apparatuses, methods, and systems relating to radiological characterization of environments are disclosed. Multi-detector probes with a plurality of detectors in a common housing may be used to substantially concurrently detect a plurality of different radiation activities and types. Multiple multi-detector probes may be used in a down-hole environment to substantially concurrently detect radioactive activity and contents of a buried waste container. Software may process, analyze, and integrate the data from the different multi-detector probes and the different detector types therein to provide source location and integrated analysis as to the source types and activity in the measured environment. Further, the integrated data may be used to compensate for differential density effects and the effects of radiation shielding materials within the volume being measured.

  11. Temporal evaluation of radiation detection system, used by the division of radiation protection of the Navy Technological Centre in Sao Paulo, Brazil

    International Nuclear Information System (INIS)

    Gontijo, Rodrigo Modesto Gadelha; Acosta, Clarice de Freitas; Ikari, Andreza Iris R.; Ferreira, Marcio de Oliveira; Alves, Henrique da Silva; Duarte, Marcelo Antonio

    2011-01-01

    This work presents a temporal evaluation of the radiation detection system used by in division of radiation protection of the CTMSP, Sao Paulo, Brazil. About fifty efficiencies results of the system were compiled over the last two years for this purpose. Less than 1% of the standard deviation was found for both portable and fixed detectors, which indicates a significant stability of the detection system used in CTMSP over the period analyzed. (author)

  12. Simulation and modeling for the stand-off radiation detection system (SORDS) using GEANT4

    Energy Technology Data Exchange (ETDEWEB)

    Hoover, Andrew S [Los Alamos National Laboratory; Wallace, Mark [Los Alamos National Laboratory; Galassi, Mark [Los Alamos National Laboratory; Mocko, Michal [Los Alamos National Laboratory; Palmer, David [Los Alamos National Laboratory; Schultz, Larry [Los Alamos National Laboratory; Tornga, Shawn [Los Alamos National Laboratory

    2009-01-01

    A Stand-Off Radiation Detection System (SORDS) is being developed through a joint effort by Raytheon, Los Alamos National Laboratory, Bubble Technology Industries, Radiation Monitoring Devices, and the Massachusetts Institute of Technology, for the Domestic Nuclear Detection Office (DNDO). The system is a mobile truck-based platform performing detection, imaging, and spectroscopic identification of gamma-ray sources. A Tri-Modal Imaging (TMI) approach combines active-mask coded aperture imaging, Compton imaging, and shadow imaging techniques. Monte Carlo simulation and modeling using the GEANT4 toolkit was used to generate realistic data for the development of imaging algorithms and associated software code.

  13. Neutron and/or gamma radiation detecting system

    International Nuclear Information System (INIS)

    Cerff, K.

    1985-01-01

    A large reception surface for the radiation to be detected is formed on a body of scintillation material (ZnS-AG with B matrix) which is adapted to convert neutron or gamma radiation into light energy. A large number of fiber light conductors is embedded in the body of scintillation material such that the fibers extend essentially parallel and fully across the reception surface of the body of scintillation material. The light energy, upon propagation along the fiber light conductors, is coupled into the conductors along the surface of the fibers which are unisotropic. This arrangement permits the use of unisotropic light conductor systems which provide for a separation of light collecting and light transmitting functions which results in a substantial reduction of light absorption losses during light transmission so that most of the light energy coupled into the fiber light conductors reaches the optoelectronic amplifier coupled to the end of the light conductors. (orig./HP) [de

  14. Position sensitive detection of neutrons in high radiation background field.

    Science.gov (United States)

    Vavrik, D; Jakubek, J; Pospisil, S; Vacik, J

    2014-01-01

    We present the development of a high-resolution position sensitive device for detection of slow neutrons in the environment of extremely high γ and e(-) radiation background. We make use of a planar silicon pixelated (pixel size: 55 × 55 μm(2)) spectroscopic Timepix detector adapted for neutron detection utilizing very thin (10)B converter placed onto detector surface. We demonstrate that electromagnetic radiation background can be discriminated from the neutron signal utilizing the fact that each particle type produces characteristic ionization tracks in the pixelated detector. Particular tracks can be distinguished by their 2D shape (in the detector plane) and spectroscopic response using single event analysis. A Cd sheet served as thermal neutron stopper as well as intensive source of gamma rays and energetic electrons. Highly efficient discrimination was successful even at very low neutron to electromagnetic background ratio about 10(-4).

  15. ACRF Instrumentation Status and Information September 2009

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2009-10-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  16. ACRF Instrumentation Status and Information April 2009

    Energy Technology Data Exchange (ETDEWEB)

    Voyles, JW

    2009-05-07

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  17. ACRF Instrumentation Status and Information August 2009

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2009-09-09

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  18. ACRF Instrumentation Status and Information July 2009

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2009-08-13

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  19. ACRF Instrumentation Status and Information - June 2009

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2009-06-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  20. ACRF Instrumentation Status and Information May 2009

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2009-05-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  1. Development of radiation detection and measurement system - Development of scintillation radiation sensor

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Hee Dong; Kim, Wan [Kyungpook National University, Taegu (Korea); Kim, Do Sung [Taegu University, Taegu (Korea)

    2000-03-01

    We have been fabricated CsI(Tl) scintillation crystals and plastic scintillators for radiation-based measuring equipment. CsI (Tl) single crystals doped with thallium as an activator were grown using the Czochralski method. The crystal structure of grown CsI(Tl) was bcc, and it was confirmed that its lattice constant was 4,568 A. The spectral range of luminescence of CsI(Tl) was 350 {approx} 700 nm independent of thallium concentration, and the fast component of the luminescence was decreased with increasing thallium concentration. The energy resolution of CsI(Tl) scintillator doped with 0.1 mole% thallium was about 9% for 137 Cs {gamma}-rays. The relation formula of {gamma}-ray energy versus energy resolution was ln(FWHM%)=-0.705ln({epsilon})+6.75. The radiation damage of CsI(Tl) increased in proportion to thallium concentration and radiation damage of CsI(Tl) increased in proportion to thallium concentration and radiation dosage, and the irradiated crystals were colored reddish. The radiation induced absorption bands appeared around 355, 425, 520 and 555 nm, and their energy level were about 3.50, 2.88, 2.39 and 2.21 eV. Plastic scintillators were fabricated thermal polymerization method. Those were polymerizing at 120 deg. C, during 72 hours, and annealing at 75 deg. C, during 24 hours. When the concentration of 1st solute was 1.5 wt% and concentration of 2nd solute was 0.01 wt%, the characteristics of scintillation were very excellent. Also 3.0 wt% tetraphenyl lead were loaded to improve the detection efficiency of {gamma}-ray. The range of emission spectrum was 400 {approx} 450nm, and the central peak was 415 nm. The radiation damage was not appear under 1*10{sup 3}Gy, but the color of plastic scintillator was changed to brown, over 1*10{sup 4}Gy exposured. 84 refs., 39 figs. (Author)

  2. Highly Sensitive Detection of UV Radiation Using a Uranium Coordination Polymer.

    Science.gov (United States)

    Liu, Wei; Dai, Xing; Xie, Jian; Silver, Mark A; Zhang, Duo; Wang, Yanlong; Cai, Yawen; Diwu, Juan; Wang, Jian; Zhou, Ruhong; Chai, Zhifang; Wang, Shuao

    2018-02-07

    The accurate detection of UV radiation is required in a wide range of chemical industries and environmental or biological related applications. Conventional methods taking advantage of semiconductor photodetectors suffer from several drawbacks such as sophisticated synthesis and manufacturing procedure, not being able to measure the accumulated UV dosage as well as high defect density in the material. Searching for new strategies or materials serving as precise UV dosage sensor with extremely low detection limit is still highly desirable. In this work, a radiation resistant uranium coordination polymer [UO 2 (L)(DMF)] (L = 5-nitroisophthalic acid, DMF = N,N-dimethylformamide, denoted as compound 1) was successfully synthesized through mild solvothermal method and investigated as a unique UV probe with the detection limit of 2.4 × 10 -7 J. On the basis of the UV dosage dependent luminescence spectra, EPR analysis, single crystal structure investigation, and the DFT calculation, the UV-induced radical quenching mechanism was confirmed. Importantly, the generated radicals are of significant stability which offers the opportunity for measuring the accumulated UV radiation dosage. Furthermore, the powder material of compound 1 was further upgraded into membrane material without loss in luminescence intensity to investigate the real application potentials. To the best of our knowledge, compound 1 represents the most sensitive coordination polymer based UV dosage probe reported to date.

  3. Methodology for Assessing Radiation Detectors Used by Emergency Responders

    International Nuclear Information System (INIS)

    Piotr Wasiolek; April Simpson

    2008-01-01

    The threat of weapons of mass destruction terrorism resulted in the U.S. Department of Homeland Security deploying large quantities of radiation detectors throughout the emergency responder community. However, emergency responders specific needs were not always met by standard health physics instrumentation used in radiation facilities. Several American National Standards Institute standards were developed and approved to evaluate the technical capabilities of detection equipment. Establishing technical capability is a critical step, but it is equally important to emergency responders that the instruments are easy to operate and can withstand the rugged situations they encounter. The System Assessment and Validation for Emergency Responders (SAVER) Program (managed by the U.S. Department of Homeland Security, Office of Grants and Training, Systems Support Division) focuses predominantly on the usability, ergonomics, readability, and other features of the detectors, rather than performance controlled by industry standards and the manufacturers. National Security Technologies, LLC, as a SAVER Technical Agent, conducts equipment evaluations using active emergency responders who are familiar with the detection equipment and knowledgeable of situations encountered in the field, which provides more relevant data to emergency responders

  4. Position-sensitive radiation monitoring (surface contamination monitor). Innovative technology summary report

    International Nuclear Information System (INIS)

    1999-06-01

    The Shonka Research Associates, Inc. Position-Sensitive Radiation Monitor both detects surface radiation and prepares electronic survey map/survey report of surveyed area automatically. The electronically recorded map can be downloaded to a personal computer for review and a map/report can be generated for inclusion in work packages. Switching from beta-gamma detection to alpha detection is relatively simple and entails moving a switch position to alpha and adjusting the voltage level to an alpha detection level. No field calibration is required when switching from beta-gamma to alpha detection. The system can be used for free-release surveys because it meets the federal detection level sensitivity limits requires for surface survey instrumentation. This technology is superior to traditionally-used floor contamination monitor (FCM) and hand-held survey instrumentation because it can precisely register locations of radioactivity and accurately correlate contamination levels to specific locations. Additionally, it can collect and store continuous radiological data in database format, which can be used to produce real-time imagery as well as automated graphics of survey data. Its flexible design can accommodate a variety of detectors. The cost of the innovative technology is 13% to 57% lower than traditional methods. This technology is suited for radiological surveys of flat surfaces at US Department of Energy (DOE) nuclear facility decontamination and decommissioning (D and D) sites or similar public or commercial sites

  5. Position-sensitive radiation monitoring (surface contamination monitor). Innovative technology summary report

    Energy Technology Data Exchange (ETDEWEB)

    1999-06-01

    The Shonka Research Associates, Inc. Position-Sensitive Radiation Monitor both detects surface radiation and prepares electronic survey map/survey report of surveyed area automatically. The electronically recorded map can be downloaded to a personal computer for review and a map/report can be generated for inclusion in work packages. Switching from beta-gamma detection to alpha detection is relatively simple and entails moving a switch position to alpha and adjusting the voltage level to an alpha detection level. No field calibration is required when switching from beta-gamma to alpha detection. The system can be used for free-release surveys because it meets the federal detection level sensitivity limits requires for surface survey instrumentation. This technology is superior to traditionally-used floor contamination monitor (FCM) and hand-held survey instrumentation because it can precisely register locations of radioactivity and accurately correlate contamination levels to specific locations. Additionally, it can collect and store continuous radiological data in database format, which can be used to produce real-time imagery as well as automated graphics of survey data. Its flexible design can accommodate a variety of detectors. The cost of the innovative technology is 13% to 57% lower than traditional methods. This technology is suited for radiological surveys of flat surfaces at US Department of Energy (DOE) nuclear facility decontamination and decommissioning (D and D) sites or similar public or commercial sites.

  6. Assessment of Radiation Background Variation for Moving Detection Systems

    Energy Technology Data Exchange (ETDEWEB)

    Miller, James Christopher [Los Alamos National Laboratory; Rennie, John Alan [Los Alamos National Laboratory; Toevs, James Waldo [Los Alamos National Laboratory; Wallace, Darrin J. [Los Alamos National Laboratory; Abhold, Mark Edward [Los Alamos National Laboratory

    2015-07-13

    The introduction points out that radiation backgrounds fluctuate across very short distances: factors include geology, soil composition, altitude, building structures, topography, and other manmade structures; and asphalt and concrete can vary significantly over short distances. Brief descriptions are given of the detection system, experimental setup, and background variation measurements. It is concluded that positive and negative gradients can greatly reduce the detection sensitivity of an MDS: negative gradients create opportunities for false negatives (nondetection), and positive gradients create a potentially unacceptable FAR (above 1%); the location of use for mobile detection is important to understand; spectroscopic systems provide more information for screening out false alarms and may be preferred for mobile use; and mobile monitor testing at LANL accounts for expected variations in the background.

  7. Nuclear electronic instrumentation

    International Nuclear Information System (INIS)

    Ramirez J, F. J.

    2010-01-01

    The activities carried out in the Instituto Nacional de Investigaciones Nucleares (ININ) in the field of the nuclear electronic instrumentation included those activities corresponding to the design and production of nuclear instruments in a first stage, as well as the internal activities of design, repair and maintenance that have supported to other projects of the institution during many years. It is mentioned of the presence and constant collaboration of the ININ with the IAEA in different projects and programs. Also, it is mentioned on the establishment of the Radiation Detectors Laboratory, which for their characteristics and repair capacities of radiation detectors of cooled semiconductor, it is only in their specialty. It is emphasized the investigation and the development in the field of new radiation detectors and applications, as well as the important contribution in this field, in institutions like: Mexican Petroleum, National Commission of Nuclear Safety and Safeguards and Federal Commission of Electricity. Finally a position of the future of these activities is made, considering the speed of the advances of the electronic and nuclear technology. (Author)

  8. Simple instrument for biochemical studies of the living human brain

    International Nuclear Information System (INIS)

    Bice, A.N.; Wagner, H.N. Jr.; Lee, M.C.; Frost, J.J.

    1986-01-01

    A simple, relatively inexpensive radiation detection system was developed for measurement of positron-emitting receptor-binding drugs in the human brain. This high-efficiency coincidence counting system requires that only a few hundred microcuries of labeled drug be administered to the subject, thereby allowing for multiple studies without an excessive radiation dose. Measurement of the binding of [ 11 C]-carfentanil, a high-affinity synthetic opiate, to opiate receptors in the presence and in the absence of a competitive opiate antagonist exemplifies the use of this system for estimating different degrees of receptor binding of drugs in the human brain. The instrument has also been used for measurement of the transport into the brain of other positron-emitting radiotracers, such as large neutral amino acids

  9. Tamper and radiation resistant instrumentation for safeguarding special nuclear materials

    International Nuclear Information System (INIS)

    Parsons, B.B.; Wells, J.L.

    1977-01-01

    A tamper-resistant liquid level/accountability instrumentation system for safeguards use has been developed and tested. The tests demonstrate the accuracy of liquid level measurement using TDR (Time Domain Reflectometry) techniques and the accuracy of differential pressure and temperature measurements utilizing a custom designed liquid level sensor probe. The calibrated liquid level, differential pressure, and temperature data provide sufficient information to accurately determine volume, density, and specific gravity. Test solutions used include ordinary tap water, diluted nitric acid in varying concentrations, and diluted uranium trioxide also in varying concentrations. System operations and preliminary test results conducted at the General Electric Midwest Fuel Recovery Plant and the National Bureau of Standards, respectively, suggest that the system will provide the safeguards inspector with an additional tool for real-time independent verification of normal operations and special nuclear materials accountancy data for chemical reprocessing plants. This paper discusses the system design concepts, including a brief description of the tamper and radiation resistant features, the preliminary test results, and the significance of the work

  10. Detection of gravitational radiation by the Doppler tracking of spacecraft

    International Nuclear Information System (INIS)

    Mashhoon, B.

    1979-01-01

    It has been suggested that the residual Doppler shift in the precision electromagnetic tracking of spacecraft be used to search for gravitational radiation that may be incident on the Earth-spacecraft system. The influence of a gravitational wave on the Doppler shift is calculated, and it is found that the residual shift is dominated by two terms: one is due to the passage of electromagnetic waves through the gravitational radiation field, and the other depends on the change in the relative velocity of the Earth and the spacecraft caused by the external wave. A detailed analysis is given of the influence of gravitational radiation on a binary system with an orbital size small compared to the wavelength of the incident radiation. It is shown that, as a consequence of the interaction with the external wave, the system makes a transition from one Keplerian orbit into another which, in general, has a different energy and angular momentum. It is therefore proposed to search for such effects in the solar system. Observations of the orbit of an artificial Earth satellite, the lunar orbit, and especially the planetary orbits offer exciting possibilities for the detection of gravitational waves of various wavelengths. From the results of the lunar laser ranging experiment and the range measurement to Mars, certain interesting limits may be established on the frequency of incidence of gravitational waves of a given flux on the Earth-Moon and the Earth-Mars systems. This is followed by a brief and preliminary analysis of the possibility of detecting gravitational radiation by measuring a residual secular Doppler shift in the satellite-to-satellite Doppler tracking of two counterorbiting drag-free spacecraft around the Earth as in the Van Patten-Everitt experiment

  11. Portable Radiation Package (PRP) Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Reynolds, R Michael [Remote Measurements and Research Company, Seattle, WA (United States)

    2017-08-03

    The Portable Radiation Package (PRP) was developed to provide basic radiation information in locations such as ships at sea where proper exposure is remote and difficult, the platform is in motion, and azimuth alignment is not fixed. Development of the PRP began at Brookhaven National Laboratory (BNL) in the mid-1990s and versions of it were deployed on ships in the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility’s Nauru-99 project. The PRP was deployed on ships in support of the National Aeronautics and Space Administration (NASA) Sensor Intercomparison for Marine Biological and Interdisciplinary Ocean Studies (SIMBIOS) program. Over the years the measurements have remained the same while the post-processing data analysis, especially for the FRSR, has evolved. This document describes the next-generation Portable Radiation Package (PRP2) that was developed for the DOE ARM Facility, under contract no. 9F-31462 from Argonne National Laboratory (ANL). The PRP2 has the same scientific principles that were well validated in prior studies, but has upgraded electronic hardware. The PRP2 approach is completely modular, both in hardware and software. Each sensor input is treated as a separate serial stream into the data collection computer. In this way the operator has complete access to each component of the system for purposes of error checking, calibration, and maintenance. The resulting system is more reliable, easier to install in complex situations, and more amenable to upgrade.

  12. ANIMMA 2009 - International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and their Applications - Compilation of slides

    International Nuclear Information System (INIS)

    Chabre, A.; Lyoussi, A.; Martin-Deidier, L.; Caverni, J.P.; Deconinck, F.; Cesarsky, C.; Kjems, J.; Spiro, M.; Abdallah, J.; Mandic, I.; Cindro, V.; Gorisek, A.; Kramberger, G.; Mikuz, M.; Hartert, J.; Bronner, J.; Franz, S.; Minano, M.; Fleta, C.; Garcia, C.; Lacasta, C.; Lozano, M.; Marco, R.; Marti, I.; Garcia, S.; Pellegrini, G.; Soldevila, U.; Ullan, M.; Larsen, R.; Downing, R.; Saunders, C.; Pavlicek, V.; Jezynski, T.; Rehlich, K.; An Liu, Z.; Nomachi, M.; Le Du, P.; Benekos, N.; Cortes Gonzales, A.; Coggeshall, J.; Liss, A.M.; Baudot, J.; Barbier, R.; Brogna, A.; Chabanat, E.; Claus, G.; Colledani, C.; Depasse, P.; Degerli, Y.; De Masi, R.; Deveaux, M.; Dorokhov, A.; Doziere, G.; Dritsa, C.; Dulinski, W.; Estre, N.; Fang, X.C.; Fontaine, J.C.; Gelin, M.; Goffe, M.; Himmi, A.; Hu-Guo, C.; Jaaskelainen, K.; Minano, M.; Bruynseraede, Y.; Benekos, N.; Collazuol, G.M.; Baudot, J.; Hoffmann, D.; Alami, R.; Marie, F.; Fontana, A.; Duval, P.Y.; Rosca, A.; Copic, K.; Iracane, D.; Rempe, J.; Shippen, D.; Choo, K.N.; Breitkreutz, H.; Petry, W.; Itagaki, W.; Zaristkiy, S.; Jammes, C.; Imel, G.; Ritter, G.; Casoli, P.; Blaise, P.; Lecouey, J.L.; Rohrmoser, A.; Bignan, G.; Bruynseraede, Y.; March, R.; Janulyte, A.; Morichi, M.; Adams, J.; Popov, V.; Costley, A.; Moreau, P.; Sabot, R.; Leyrat, J.P.; Angelone, M.; Flament, O.; Thfoin, I.; Boullis, B.; Rouquerol, J.; Nonell, A.; Simon, A.C.; Lyoussi, A.; De Bruycker, A.; Ducros, G.; Katsuyama, K.; Barat, E.; Swinhoe, M.; Dogny, S.; Carrel, F.; Granier, G.; Raoux, A.C.; Pluquet, A.; Ahlen, S.; Butchins, L.; Porta, A.; Valkovic, V.; Dazeley, S.; Furuta, H.; Quiter, B.; Piccotti, A.; Swinhoe, M.; Bruggeman, M.; Ruddy, F.; El kanawati, W.; Cabrera-Palmer, B.; Sweet, M.; Parrat, D.; Cavedon, J.M.; Babu, C.; Baskaran, B.; Villard, J.F.; Buimistriuc, G.; Rosenkrantz, E.; Coulon, R.; Schyns, M.; Bronson, F.; Giraud, A.; Vuillemard, C.; Ait Abderrahim, H.; Marie, F.; Beeley, P.; Andre, J.; Turpin, L.; Waker, A.; Pafilis, C.; Townsend, D.; Chatal, J.F.; Gao, W.; Kawachi, N.; Townsend, D.; Le Foulher, F.; Magne, S.; Valkovic, V.; Rottner, B.; Lebrun, A.; Ianakiev, K.; Giot, M.; Flescher, H.

    2009-01-01

    The program of this conference is focused on instrumentation, but emphasizes the latest developments in all measurement stages: nuclear radiation detection and in-pile measurements, modelling, electronics, signal acquisition and analysis, radiotherapy, interpretation and associated training activities. This document is composed of the program of the conference and of the slides of about 102 presentations

  13. Neutron instrumentation for biology

    Energy Technology Data Exchange (ETDEWEB)

    Mason, S.A. [Institut Laue-Langevin, Grenoble (France)

    1994-12-31

    In the October 1994 round of proposals at the ILL, the external biology review sub- committee was asked to allocate neutron beam time to a wide range of experiments, on almost half the total number of scheduled neutron instruments: on 3 diffractometers, on 3 small angle scattering instruments, and on some 6 inelastic scattering spectrometers. In the 3.5 years since the temporary reactor shutdown, the ILL`s management structure has been optimized, budgets and staff have been trimmed, the ILL reactor has been re-built, and many of the instruments up-graded, many powerful (mainly Unix) workstations have been introduced, and the neighboring European Synchrotron Radiation Facility has established itself as the leading synchrotron radiation source and has started its official user program. The ILL reactor remains the world`s most intense dedicated neutron source. In this challenging context, it is of interest to review briefly the park of ILL instruments used to study the structure and energetics of small and large biological systems. A brief summary will be made of each class of experiments actually proposed in the latest ILL proposal round.

  14. Observations of Infrared Radiative Cooling in the Thermosphere on Daily to Multiyear Timescales from the TIMED/SABER Instrument

    Science.gov (United States)

    Mlynczak, Martin G.; Hunt, Linda A.; Marshall, B. Thomas; Martin-Torres, F. Javier; Mertens, Christopher J.; Russell, James M., III; Remsberg, Ellis E.; Lopez-Puertas, Manuel; Picard, Richard; Winick, Jeremy; hide

    2009-01-01

    We present observations of the infrared radiative cooling by carbon dioxide (CO2) and nitric oxide (NO) in Earth s thermosphere. These data have been taken over a period of 7 years by the SABER instrument on the NASA TIMED satellite and are the dominant radiative cooling mechanisms for the thermosphere. From the SABER observations we derive vertical profiles of radiative cooling rates (W/cu m), radiative fluxes (W/sq m), and radiated power (W). In the period from January 2002 through January 2009 we observe a large decrease in the cooling rates, fluxes, and power consistent with the declining phase of solar cycle. The power radiated by NO during 2008 when the Sun exhibited few sunspots was nearly one order of magnitude smaller than the peak power observed shortly after the mission began. Substantial short-term variability in the infrared emissions is also observed throughout the entire mission duration. Radiative cooling rates and radiative fluxes from NO exhibit fundamentally different latitude dependence than do those from CO2, with the NO fluxes and cooling rates being largest at high latitudes and polar regions. The cooling rates are shown to be derived relatively independent of the collisional and radiative processes that drive the departure from local thermodynamic equilibrium (LTE) in the CO2 15 m and the NO 5.3 m vibration-rotation bands. The observed NO and CO2 cooling rates have been compiled into a separate dataset and represent a climate data record that is available for use in assessments of radiative cooling in upper atmosphere general circulation models.

  15. Radioactive standards and calibration methods for contamination monitoring instruments

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Makoto [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-06-01

    Contamination monitoring in the facilities for handling unsealed radioactive materials is one of the most important procedures for radiation protection as well as radiation dose monitoring. For implementation of the proper contamination monitoring, radiation measuring instruments should not only be suitable to the purpose of monitoring, but also be well calibrated for the objective qualities of measurement. In the calibration of contamination monitoring instruments, quality reference activities need to be used. They are supplied in different such as extended sources, radioactive solutions or radioactive gases. These reference activities must be traceable to the national standards or equivalent standards. On the other hand, the appropriate calibration methods must be applied for each type of contamination monitoring instruments. In this paper, the concepts of calibration for contamination monitoring instruments, reference sources, determination methods of reference quantities and practical calibration methods of contamination monitoring instruments, including the procedures carried out in Japan Atomic Energy Research Institute and some relevant experimental data. (G.K.)

  16. Radiation detection system

    Science.gov (United States)

    Whited, R.C.

    A system for obtaining improved resolution in relatively thick semiconductor radiation detectors, such as HgI/sub 2/, which exhibit significant hole trapping. Two amplifiers are used: the first measures the charge collected and the second the contribution of the electrons to the charge collected. The outputs of the two amplifiers are utilized to unfold the total charge generated within the detector in response to a radiation event.

  17. Performance acceptance test of a portable instrument to detect uranium in water at the DOE Advanced Waste Water Treatment Plant, Fernald, Ohio

    International Nuclear Information System (INIS)

    Anderson, M.S.; Weeks, S.J.

    1997-01-01

    The Eppendorf-Biotronik Model IC 2001-2, a portable field ruggedized ion chromatography instrument, was rigorously tested at the DOE Advanced Waste Water Treatment Plant, Fernald, Ohio. This instrument rapidly detected the uranium concentration in water, and has a detection limit in the low ppb range without using the sample concentrating feature. The test set of samples analyzed included: ''Real World'' water samples from the AWWT containing uranium concentrations in the 9--110 ppb range, a sample blank, and a performance evaluation sample. The AWWT samples contained sets of both raw water and acid-preserved water samples. Selected samples were analyzed in quadruplicate to asses the instrument's precision, and these results were compared with the results from an off-site confirmatory laboratory to assess the instrument's accuracy. Additional comparisons with on-site laboratory instruments, Chemcheck KPA-11 and Scintrex UA-3 are reported. Overall, the Eppendorf-Biotronik IC 2001-2 performed exceptionally well providing a detection limit in the low ppb region (< 10 ppb) and giving rapid (< 5 minutes) accurate and reproducible analytical results for the AWWT, ''real world'', water samples with uranium concentrations in the region of interest (10--40 ppb). The per sample operating cost for this instrument is equivalent to the per sample cost for the currently used KPA. The time required to analyze a sample and provide a result is approximately the same for the CI 2001-2, KPA, and Scintrex instruments

  18. Environmental radiation monitoring of Vizag City

    International Nuclear Information System (INIS)

    Sreekanth, B.; Narsaiah, M.V.R.; Saindane, Shashank; Pujari, Raju; Krishna, N.S.; Sambamurthy, T.; Chaudhury, Probal; Pradeepkumar, K.S.

    2014-01-01

    Radiological impact assessment is to be carried out following any radiological emergency to implement the required counter measures. A ground based environmental radiation monitoring of Vizag city has been carried out by installing various radiation monitoring instruments in a vehicle to generate the base line radiation data. It also helps to check the illicit trafficking of radioactive sources and also identifying the orphan sources. The average background radiation level observed in Vizag city was 80 nGy/h. Database of baseline radiation level with GPS location at all important locations of the whole city has been developed. No illicit trafficking of radioactive materials and orphan sources were detected during the survey. All the detectors used in the survey shown good correlation in their response. The study showed that mobile monitoring methodology will be useful in the quick assessment of radiological impact and strengthens the decision makers in reducing consequences by initiating immediate counter measures

  19. Activities of Radiation Standard Section

    International Nuclear Information System (INIS)

    Kannan, A.; Rao, P.S.; Sachadev, R.N.; Shaha, V.V.; Sharma, D.; Srivastava, P.K.

    1992-01-01

    A brief account of the various facilities and services provided by the Radiation Standards Section (RSS) of the Bhabha Atomic Research Centre, Bombay is given. RSS maintains the primary and secondary standards of various parameters of radiation measurements. It ensures accurate radiological measurements as per international requirements, through periodic international intercomparisons of national standards. It also provides calibration services to various users of radiation sources and instruments. The activities of RSS are described under the headings: (1) Radiological Metrology Standards, (2) Radionuclide Standards, Neutron Metrology, (4) Instruments Calibration, (5) Non-ionizing Radiations, and (6) Instrumentation. (author). figs., tabs

  20. Study of radiation detectors response in standard X, gamma and beta radiation standard beams

    International Nuclear Information System (INIS)

    Nonato, Fernanda Beatrice Conceicao

    2010-01-01

    The response of 76 Geiger-Mueller detectors, 4 semiconductor detectors and 34 ionization chambers were studied. Many of them were calibrated with gamma radiation beams ( 37 Cs and 60 Co), and some of them were tested in beta radiation ( 90 Sr+ 9' 0Y e 204 Tl) and X radiation (N-60, N-80, N-100, N-150) beams. For all three types of radiation, the calibration factors of the instruments were obtained, and the energy and angular dependences were studied. For beta and gamma radiation, the angular dependence was studied for incident radiation angles of 0 deg and +- 45 deg. The curves of the response of the instruments were obtained over an angle interval of 0 deg to +- 90 deg, for gamma, beta and X radiations. The calibration factors obtained for beta radiation were compared to those obtained for gamma radiation. For gamma radiation, 24 of the 66 tested Geiger-Mueller detectors presented results for the energy dependence according to international recommendation of ISO 4037-2 and 56 were in accordance with the Brazilian ABNT 10011 recommendation. The ionization chambers and semiconductors were in accordance to national and international recommendations. All instruments showed angular dependence less than 40%. For beta radiation, the instruments showed unsatisfactory results for the energy dependence and angular dependence. For X radiation, the ionization chambers presented results for energy dependence according to the national recommendation, and the angular dependence was less than 40%. (author)

  1. Multi-channel Waveform Sampling ASIC for radiation detection and measurement

    International Nuclear Information System (INIS)

    Shimazoe, K.; Takahashi, H.; Yeom, J.Y.; Furumiya, T.; Ohi, J.

    2013-01-01

    We have designed and fabricated a 16-channel Waveform Sampling ASIC for radiation detection and measurement. Waveform sampling is very important for the pulse shape analysis and discrimination, which is often used in radiation detection to discriminate different radiations such as alpha, beta and gamma rays. One channel of the fabricated ASIC consists of a charge-sensitive preamplifier, a VGA (Variable Gain Amplifier), an ADC (Analog to Digital Converter) and digital circuits. The preamplifier converts the current signal to the voltage signal, and the VGA amplifies the signal to appropriate level for the ADC. The ADC was designed to digitize the waveform with a frequency of 100 MHz and a resolution of 6bits. Digital circuits consist of a free-running ADC and a multiplexer which were designed to convert a digitized 100 MHz/6bit signal to a 200 MHz/3bit one, which is effective for the reduction of the number and for the achievement of the high integration in one chip. This chip was designed and fabricated with 0.35 μm CMOS technology by ROHM and the size of the ASIC is 4.9 mm by 4.9 mm. The design concept and some experimental results are shown in this paper. -- Highlights: ► Waveform sampling (WS) ASIC is newly developed for pulse shape discrimination. ► WS ASIC can be used for radiation measurement and discrimination. ► WS ASIC is fabricated by submicron CMOS technology for 5 mm × 5 mm area. ► WS ASIC achieves high integration and can be used in very limited space

  2. Sonic Detection and Ranging (SODAR) Wind Profiler Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Coulter, Richard L. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-04-01

    The SODAR (Sonic Detection and Ranging) wind profiler measures wind profiles and backscattered signal strength between (nominally) 15 meters (m) and 500 m. It operates by transmitting acoustic energy into the atmosphere and measuring the strength and frequency of backscattered energy. The strength of the backscattered signal is determined by the strength of temperature inhomogeneities with size on the order of 10 centimeters (cm). Assuming the scattering elements in the atmosphere are moving with the mean wind, the horizontal wind field can be derived. The U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) Climate Research Facility Mobile Facility (AMF) has a system developed by Scintec, Inc. that transmits a sequence of frequencies to enhance signal determination.

  3. Photostimulated luminescence detection and radiation effects on cinnamon (Cinnamomum zeylanicum) spice

    International Nuclear Information System (INIS)

    Marcazzó, J.; Sanchez-Barrera, C.E.; Urbina-Zavala, A.; Cruz-Zaragoza, E.

    2015-01-01

    The increase of disease borne pathogens in foods has promoted the use of new technologies in order to eliminate these pathogen microorganisms and extend the shelf-life of the foodstuffs. In particular, Cinnamon (Cinnamomum zeylanicum) contains an important number of pathogen microorganisms and it is frequently sterilized by gamma radiation. However, it is important to develop the detection methods for irradiated food in order to keep the dose control and also to analyze the radiation effects in their chemical property. This work reports (i) the photostimulated luminescence (PSL) detection of irradiated cinnamon and thermoluminescence (TL) detection of the inorganic polymineral fraction separated from this spice, and (ii) the proximate chemical analysis carried out on fat, protein and dietetic fiber contents. The detection limits using the PSL and TL methods were 500 Gy and 10 Gy, respectively, and the fat content was increased significantly with the gamma dose that could be related to the lipid oxidation in the cinnamon. - Highlights: • Samples of cinnamon (Cinnamomum zeylanicum) were studied by TL and PSL methods. • The cinnamon was detected as irradiated at a dose of 500 Gy using PSL. • TL method shows an excellent linear response for doses lesser than 500 Gy. • A proximate chemical analysis was carried out on fat, protein and dietetic fiber. • The TL and PSL responses can be used for dose control in commercial cinnamon

  4. Technical specifications manual for the MARK-1 pulsed ionizing radiation detection system. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Lawrence, R.S.; Harker, Y.D.; Jones, J.L.; Hoggan, J.M.

    1993-03-01

    The MARK-1 detection system was developed by the Idaho National Engineering Laboratory for the US Department of Energy Office of Arms Control and Nonproliferation. The completely portable system was designed for the detection and analysis of intense photon emissions from pulsed ionizing radiation sources. This manual presents the technical design specifications for the MARK-1 detection system and was written primarily to assist the support or service technician in the service, calibration, and repair of the system. The manual presents the general detection system theory, the MARK-1 component design specifications, the acquisition and control software, the data processing sequence, and the system calibration procedure. A second manual entitled: Volume 2: Operations Manual for the MARK-1 Pulsed Ionizing Radiation Detection System (USDOE Report WINCO-1108, September 1992) provides a general operational description of the MARK-1 detection system. The Operations Manual was written primarily to assist the field operator in system operations and analysis of the data.

  5. Evaluation of the Detection Efficiency of LYSO Scintillator in the Fiber-Optic Radiation Sensor

    Directory of Open Access Journals (Sweden)

    Chan Hee Park

    2014-01-01

    Full Text Available The aim of this study was to develop and evaluate fiber-optic sensors for the remote detection of gamma rays in areas that are difficult to access, such as a spent fuel pool. The fiber-optic sensor consists of a light-generating probe, such as scintillators for radiation detection, plastic optical fibers, and light-measuring devices, such as PMT. The (Lu,Y2SiO5:Ce(LYSO:Ce scintillator was chosen as the light-generating probe. The (Lu,Y2SiO5:Ce(LYSO:Ce scintillator has higher scintillation efficiency than the others and transmits light well through an optical fiber because its refraction index is similar to the refractive index of the optical fiber. The fiber-optic radiation sensor using the (Lu,Y2SiO5:Ce(LYSO:Ce scintillator was evaluated in terms of the detection efficiency and reproducibility for examining its applicability as a radiation sensor.

  6. Nuclear radiation detectors

    International Nuclear Information System (INIS)

    Kapoor, S.S.; Ramamurthy, V.S.

    1986-01-01

    The present monograph is intended to treat the commonly used detectors in the field of nuclear physics covering important developments of the recent years. After a general introduction, a brief account of interaction of radiation with matter relevant to the processes in radiation detection is given in Chapter II. In addition to the ionization chamber, proportional counters and Geiger Mueller counters, several gas-filled detectors of advanced design such as those recently developed for heavy ion physics and other types of studies have been covered in Chapter III. Semiconductor detectors are dealt with in Chapter IV. The scintillation detectors which function by sensing the photons emitted by the luminescence process during the interaction of the impinging radiation with the scintillation detector medium are described in Chapter V. The topic of neutron detectors is covered in Chapter VI, as in this case the emphasis is more on the method of neutron detection rather than on detector type. Electronic instrumentation related to signal pulse processing dealt with in Chapter VII. The track etch detectors based on the visualization of the track of the impinging charge particle have also been briefly covered in the last chapter. The scope of this monograph is confined to detectors commonly used in low and medium energy nuclear physics research and applications of nuclear techniques. The monograph is intended for post-graduate students and those beginning to work with the radiation detectors. (author)

  7. A comparison of RANZCR and Singapore-designed radiation oncology practice audit instruments: how does reproducibility affect future approaches to revalidation

    International Nuclear Information System (INIS)

    Lu, Jiade J.; Wynne, Christopher J.; Kumar, Mahesh B.; Shakespeare, Thomas P.; Mukherjee, Rahul; Back, Michael F.

    2004-01-01

    Physician competency assessment requires the use of validated methods and instruments. The Royal Australian and New Zealand College of Radiologists (RANZCR) developed a draft audit form to be evaluated as a competency assessment instrument for radiation oncologists (ROs) in Australasia. We evaluated the reliability of the RANZCR instrument as well as a separate The Cancer Institute (TCI) Singapore-designed instrument by having two ROs perform an independent chart review of 80 randomly selected patients seen at The Cancer Institute (TCI), Singapore. Both RANZCR and TCI Singapore instruments were used to score each chart. Inter- and intra-observer reliability for both audit instruments were compared using misclassification rates as the primary end-point. Overall, for inter-observer reproducibility, 2.3% of TCI Singapore items were misclassified compared to 22.3% of RANZCR items (P < 0.0001, 100.00% confidence that TCI instrument has less inter-observer misclassification). For intra-observer reproducibility, 2.4% of TCI Singapore items were misclassified compared to 13.6% of RANZCR items (P < 0.0001, 100.00% confidence that TCI instrument has less intra-observer misclassification). The proposed RANZCR RO revalidation audit instrument requires further refinement to improve validity. Several items require modification or removal because of lack of reliability, whereas inclusion of other important and reproducible items can be incorporated as demonstrated by the TCI Singapore instrument. The TCI Singapore instrument also has the advantage of incorporating a simple scoring system and criticality index to allow discrimination between ROs and comparisons against future College standards Copyright (2004) Blackwell Publishing Asia Pty Ltd

  8. Project Radiation protection, Annual report 1994

    International Nuclear Information System (INIS)

    Ninkovic, M.M.

    1994-12-01

    According to the action plan for the period 1991-1995, the main objective of this project during 1994 was to provide operational basis, methods and procedures for solving the radiation protection problems that might appear under routine working conditions and handling of radiation sources. The aim was also to provide special methods for action in case of accidents that could affect the employed staff and the population. Overall activity was directed to maintaining and providing personnel, instrumentation, and methods for the following special radiation protection measures: operational control of the radiation field and contamination; calibration of the radiation and dosimetry instruments-secondary dosimetry metrology laboratory; instrumentation and measuring systems for radiation protection; control of environmental transfer of radioactive material; medical radiation protection [sr

  9. Quality control of nuclear medicine instruments

    International Nuclear Information System (INIS)

    1984-11-01

    This document, which gives detailed guidance on the quality control of the various electronic instruments used for radiation detection and measurement in nuclear medicine, stems from the work of two Advisory Groups convened by the International Atomic Energy Agency (IAEA). A preliminary document, including recommended test schedules but lacking actual protocols for the tests, was drawn up by the first of these groups, meeting at the IAEA Headquarters in Vienna in 1979. A revised and extended version, incorporating recommended test protocols, was prepared by the second Group, meeting likewise in Vienna in 1982. This version is the model for the present text. The document should be of value to all nuclear medicine units, and especially to those in developing countries, in the initiation or revision of schemes for the quality control of their instruments. Its recommendations have provided the basis for instruction in two IAEA regional technical co-operation projects in the subject field, one initiated in 1981 for countries of Latin America and one initiated in 1982 for countries of Asia and the Pacific

  10. Ionizing radiation-induced DNA injury and damage detection in patients with breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Borrego-Soto, Gissela; Ortiz-Lopez, Rocio; Rojas-Martinez, Augusto, E-mail: arojasmtz@gmail.com, E-mail: augusto.rojasm@uanl.mx [Departamento de Bioquímica y Medicina Molecular, Facultad de Medicina, Universidad Autónoma de Nuevo León, Monterrey, Nuevo León (Mexico)

    2015-10-15

    Breast cancer is the most common malignancy in women. Radiotherapy is frequently used in patients with breast cancer, but some patients may be more susceptible to ionizing radiation, and increased exposure to radiation sources may be associated to radiation adverse events. This susceptibility may be related to deficiencies in DNA repair mechanisms that are activated after cell-radiation, which causes DNA damage, particularly DNA double strand breaks. Some of these genetic susceptibilities in DNA-repair mechanisms are implicated in the etiology of hereditary breast/ovarian cancer (pathologic mutations in the BRCA 1 and 2 genes), but other less penetrant variants in genes involved in sporadic breast cancer have been described. These same genetic susceptibilities may be involved in negative radiotherapeutic outcomes. For these reasons, it is necessary to implement methods for detecting patients who are susceptible to radiotherapy-related adverse events. This review discusses mechanisms of DNA damage and repair, genes related to these functions, and the diagnosis methods designed and under research for detection of breast cancer patients with increased radiosensitivity. (author)

  11. Modern instrumentation for radiation introscopic testing of welding quality

    International Nuclear Information System (INIS)

    Sosnin, F.R.

    1985-01-01

    Modern instrumenlation used for radiation introscopy of welded joints is discussed. the absolute (relative) sensitivity of radiation testing, resolution range, efficiency are considered as basic parameters of introscopes. The characteristics of fluoroscopes, radiation-television installations with the external scintillator and radiative image converter as well as with X-ray vidicons are given. The characterisitcs of radiation introscopes with manipulators to move objects being tested are analysed as well as digitized radiation introscopes

  12. Transient photoconductive gain in a-Si:H devices and its applications in radiation detection

    International Nuclear Information System (INIS)

    Lee, H.K.; Suh, T.S.; Choe, B.Y.; Shinn, K.S.; Perez-Mendez, V.

    1997-01-01

    Using the transient behavior of the photoconductive-gain mechanism, a signal gain in radiation detection with a-Si:H devices may be possible. The photoconductive gain mechanism in two types of hydrogenated amorphous silicon devices, p-i-n and n-i-n configurations, was investigated in connection with applications to radiation detection. Photoconductive gain was measured in two time scales: one for short pulses of visible light ( 2 . Various gain results are discussed in terms of the device structure, applied bias and dark-current density. (orig.)

  13. Role of electroweak radiation in predictions for dark matter indirect detection

    Energy Technology Data Exchange (ETDEWEB)

    Ali Cavasonza, Leila; Pellen, Mathieu; Kraemer, Michael [RWTH Aachen, Aachen (Germany)

    2015-07-01

    A very exciting challenge in particle and astroparticle physics is the exploration of the nature of dark matter. The evidences of the existence of dark matter are also the strongest phenomenological indications for physics beyond the Standard Model. A huge experimental effort is currently made at colliders and via astrophysical experiments to shed light on the nature of dark matter: dark matter may be produced at colliders or detected through direct and indirect detection experiments. The interplay and complementarity between these different approaches offers extraordinary opportunities to improve our understanding of the nature of dark matter or to set constraints on dark matter models. In indirect detection one searches for dark matter annihilation products, that produce secondary antimatter particles like positrons and antiprotons. Such antimatter particles propagate through the Galaxy and can be detected at Earth by astrophysical experiments. Particularly interesting is the importance of electroweak corrections to the predictions for the expected fluxes at Earth. The inclusion of EW radiation from the primary dark matter annihilation products can significantly affect the spectra of the secondary SM particles. The EW radiation can be described using fragmentation functions, as done for instance in QCD. We study the quality of this approximation in a simplified SUSY model and in a UED model.

  14. DETECTION OF DRUGSTORE BEETLES IN 9975 PACKAGES USING ACOUSTIC EMISSIONS

    Energy Technology Data Exchange (ETDEWEB)

    Shull, D.

    2013-03-04

    This report documents the initial feasibility tests performed using a commercial acoustic emission instrument for the purpose of detecting beetles in Department of Energy 9975 shipping packages. The device selected for this testing was a commercial handheld instrument and probe developed for the detection of termites, weevils, beetles and other insect infestations in wooden structures, trees, plants and soil. The results of two rounds of testing are presented. The first tests were performed by the vendor using only the hand-held instrument’s indications and real-time operator analysis of the audio signal content. The second tests included hands-free positioning of the instrument probe and post-collection analysis of the recorded audio signal content including audio background comparisons. The test results indicate that the system is promising for detecting the presence of drugstore beetles, however, additional work would be needed to improve the ease of detection and to automate the signal processing to eliminate the need for human interpretation. Mechanisms for hands-free positioning of the probe and audio background discrimination are also necessary for reliable detection and to reduce potential operator dose in radiation environments.

  15. Spectrometer system for diffuse extreme ultraviolet radiation

    Science.gov (United States)

    Labov, Simon E.

    1989-01-01

    A unique grazing incidence spectrometer system has been designed to study diffuse line emission between 80 and 650 A with 10-30 A resolution. The minimum detectable emission line strength during a 5-min observation ranges from 100-2000 ph/sq cm sec str. The instrument uses mechanically ruled reflection gratings placed in front of a linear array of mirrors. These mirrors focus the spectral image on microchannel plate detectors located behind thin filters. The field of view is 40 min of arc by 15 deg, and there is no spatial imaging. This instrument has been fabricated, calibrated, and successfully flown on a sounding rocket to observe the astronomical background radiation.

  16. Instrument failure detection of flow measurement in the feedwater system of the Paks Nuclear Power Plant, Hungary

    International Nuclear Information System (INIS)

    Racz, A.

    1990-12-01

    The applicability of two different methods for early detection of instrument failures of the flow measurement in feedwater systems are investigated. Both methods are based on Kalman filtering technique of stochastic processes. The reliability of the model for description of a feedwater system is checked by comparing calculated values with measured data. Possible instrument failures are simulated in order to show the capability of the proposed procedures. A practical measurement system arrangement is suggested. (author) 10 refs.; 16 figs.; 4 tabs

  17. Instrumentation

    International Nuclear Information System (INIS)

    Muehllehner, G.; Colsher, J.G.

    1982-01-01

    This chapter reviews the parameters which are important to positron-imaging instruments. It summarizes the options which various groups have explored in designing tomographs and the methods which have been developed to overcome some of the limitations inherent in the technique as well as in present instruments. The chapter is not presented as a defense of positron imaging versus single-photon or other imaging modality, neither does it contain a description of various existing instruments, but rather stresses their common properties and problems. Design parameters which are considered are resolution, sampling requirements, sensitivity, methods of eliminating scattered radiation, random coincidences and attenuation. The implementation of these parameters is considered, with special reference to sampling, choice of detector material, detector ring diameter and shielding and variations in point spread function. Quantitation problems discussed are normalization, and attenuation and random corrections. Present developments mentioned are noise reduction through time-of-flight-assisted tomography and signal to noise improvements through high intrinsic resolution. Extensive bibliography. (U.K.)

  18. Ticor-based scintillation detectors for detection of mixed radiation

    CERN Document Server

    Litvinov, L A; Kolner, V B; Ryzhikov, V D; Volkov, V G; Tarasov, V A; Zelenskaya, O V

    2002-01-01

    Detection of mixed radiation of thermal neutrons and gamma-rays have been realized using a new ceramic material based on small-crystalline long-wave scintillator alpha-Al sub 2 O sub 3 :Ti (Ticor) and lithium fluoride. Characteristics are presented for scintillators with Si-PIN-PD type photoreceivers and PMT under sup 2 sup 3 sup 9 Pu alpha-particles, sup 2 sup 0 sup 7 Bi internal conversion electrons,as well as sup 2 sup 4 sup 1 Am and sup 1 sup 3 sup 7 Cs gamma-quanta. Detection efficiency of thermal neutron is estimated for composite materials based on Ticor and lithium fluoride.

  19. Instrument cables and ceramic-to-metal seals for fusion-environment service

    International Nuclear Information System (INIS)

    Cannon, C.P.

    1982-10-01

    The intent of this paper is to form a technical basis to address questions pertinent to the use of instrument cables, ceramic-to-metal seals, and connector components in a fusion environment. The service environment of future fusion devices poses a unique challenge to instrumentation. The radiation environment of 14 MeV neutrons is markedly different from other instrumented radiation environments. There exist other environmental concerns as well (some instruments may operate at elevated temperatures, etc)

  20. Radiation and detection of gravitational waves in laboratory conditions

    International Nuclear Information System (INIS)

    Bogolyubov, P.N.; Pisarev, A.F.; Shavokhina, N.S.

    1981-01-01

    Two variants are proposed and analyzed for an experiment on radiation and detection of gravitational waves in laboratory conditions in the optical and superhigh frequency range (band). In the first variant the laser light is parametrically transformed to the gravitational wave in the optical-inhomogeneous medium. The gravitational flux produced is registered by the inverse parametric transformation of the gravitational to light wave. In the second variant the radiation of gravitational waves is realized through hypersonic oscillations in piezocrystals, and the reception of waves is made by the superconducting coaxial resonator in which the gravitational wave resonantly transforms into the electromag= . netic wave. The analysis performed testifies to the possibility of an experiment of this type at the present time [ru

  1. Suggestions of radiation protection instruments in ships used for transporting spent fuel elements from nuclear power plants to central stores and further to fuel reprocessing plants

    International Nuclear Information System (INIS)

    Warenmo, G.

    1979-01-01

    Some radiation protection measures are necessary in ships which will be used for transporting spent fuel elements from nuclear power plants to central stores and further to fuel reprocessing plants in order to protect the crew from unnecessarily high radiation doses and to ensure that not allowable values occur. Such measures are discussed in this report as well as suitable radiation protection instruments for such ships. (E.R.)

  2. Radiation detection technique on the fishery foods

    International Nuclear Information System (INIS)

    Oikawa, Hiroshi; Satomi, Masataka; Nakamura, Koji; Yano, Yutaka

    1999-01-01

    Recently irradiation of fishery products such as sea bream, lobster etc has been spreading in South-east Asia. It is thus necessary to establish a detection technique for irradiated foods . This study aimed to investigate the effects of irradiation on the production of tyrosine isomers with relation to the status of food sample (frozen and cold-storage) and also the stabilities of the isomers in frozen foods after irradiation. Production of tyrosin isomers (meta-tyrosine, ortho-tyrosine) due to γ-ray irradiation (5 kGy) were observed in the muscles of frozen prawns as well as those at room temperature and the contents of these isomers after the irradiation was not different between the two states of the sample. The content increased depending on the radiation dose. The contents of these tyrosine isomers were not changed after storage at -20degC for 120 days. Therefore, it was thought that the tyrosine isomers were available as an effective indicator for detection of an irradiated food. (M.N.)

  3. Principles of radiation interaction in matter and detection

    CERN Document Server

    Leroy, Claude

    2016-01-01

    The fourth edition of this book has been widely revised. It includes additional chapters and some sections are complemented with either new ones or an extension of their content. In this latest edition a complete treatment of the physics and properties of semiconductors is presented, covering transport phenomena in semiconductors, scattering mechanisms, radiation effects and displacement damages. Furthermore, this edition presents a comprehensive treatment of the Coulomb scattering on screened nuclear potentials resulting from electrons, protons, light- and heavy-ions — ranging from (very) low up to ultra-relativistic kinetic energies — and allowing one to derive the corresponding NIEL (non-ionizing energy-loss) doses deposited in any material. The contents are organized into two parts: Chapters 1 to 7 cover Particle Interactions and Displacement Damage while the remaining chapters focus on Radiation Environments and Particle Detection. This book can serve as reference for graduate students and final-y...

  4. Possible standoff detection of ionizing radiation using high-power THz electromagnetic waves

    Science.gov (United States)

    Nusinovich, Gregory S.; Sprangle, Phillip; Romero-Talamas, Carlos A.; Rodgers, John; Pu, Ruifeng; Kashyn, Dmytro G.; Antonsen, Thomas M., Jr.; Granatstein, Victor L.

    2012-06-01

    Recently, a new method of remote detection of concealed radioactive materials was proposed. This method is based on focusing high-power short wavelength electromagnetic radiation in a small volume where the wave electric field exceeds the breakdown threshold. In the presence of free electrons caused by ionizing radiation, in this volume an avalanche discharge can then be initiated. When the wavelength is short enough, the probability of having even one free electron in this small volume in the absence of additional sources of ionization is low. Hence, a high breakdown rate will indicate that in the vicinity of this volume there are some materials causing ionization of air. To prove this concept a 0.67 THz gyrotron delivering 200-300 kW power in 10 microsecond pulses is under development. This method of standoff detection of concealed sources of ionizing radiation requires a wide range of studies, viz., evaluation of possible range, THz power and pulse duration, production of free electrons in air by gamma rays penetrating through container walls, statistical delay time in initiation of the breakdown in the case of low electron density, temporal evolution of plasma structure in the breakdown and scattering of THz radiation from small plasma objects. Most of these issues are discussed in the paper.

  5. Detection of radiation-induced hydrocarbons in baked sponged cake prepared with irradiated liquid egg

    Science.gov (United States)

    Schulzki, G.; Spiegelberg, A.; Bögl, K. W.; Schreiber, G. A.

    1995-02-01

    For identification of irradiated food, radiation-induced volatile hydrocarbons (HC) are determined by gas chromatography in the non-polar fraction of fat. However, in complex food matrices the detection is often disturbed by fat-associated compounds. On-line coupling of high performance liquid chromatography (LC) and gas chromatography (GC) is very efficient to remove such compounds from the HC fraction. The high sensitivity of this fast and efficient technique is demonstrated by the example of detection of radiation-induced HC in fat isolated from baked sponge cake which had been prepared with irradiated liquid egg.

  6. New sources and instrumentation for neutrons in biology

    DEFF Research Database (Denmark)

    Teixeira, S. C. M.; Zaccai, G.; Ankner, J.

    2008-01-01

    Neutron radiation offers significant advantages for the study of biological molecular structure and dynamics. A broad and significant effort towards instrumental and methodological development to facilitate biology experiments at neutron sources worldwide is reviewed.......Neutron radiation offers significant advantages for the study of biological molecular structure and dynamics. A broad and significant effort towards instrumental and methodological development to facilitate biology experiments at neutron sources worldwide is reviewed....

  7. CERN Radiation Protection (RP) calibration facilities

    CERN Document Server

    AUTHOR|(CDS)2082069; Macián-Juan, Rafael

    Radiation protection calibration facilities are essential to ensure the correct operation of radiation protection instrumentation. Calibrations are performed in specific radiation fields according to the type of instrument to be calibrated: neutrons, photons, X-rays, beta and alpha particles. Some of the instruments are also tested in mixed radiation fields as often encountered close to high-energy particle accelerators. Moreover, calibration facilities are of great importance to evaluate the performance of prototype detectors; testing and measuring the response of a prototype detector to well-known and -characterized radiation fields contributes to improving and optimizing its design and capabilities. The CERN Radiation Protection group is in charge of performing the regular calibrations of all CERN radiation protection devices; these include operational and passive dosimeters, neutron and photon survey-meters, and fixed radiation detectors to monitor the ambient dose equivalent, H*(10), inside CERN accelera...

  8. Polarization sensitive detection of 100 GHz radiation by high mobility field-effect transistors

    International Nuclear Information System (INIS)

    Sakowicz, M.; Lusakowski, J.; Karpierz, K.; Grynberg, M.; Knap, W.; Gwarek, W.

    2008-01-01

    Detection of 100 GHz electromagnetic radiation by a GaAs/AlGaAs high electron mobility field-effect transistor was investigated at 300 K as a function of the angle α between the direction of linear polarization of the radiation and the symmetry axis of the transistor. The angular dependence of the detected signal was found to be A 0 cos 2 (α-α 0 )+C with A 0 , α 0 , and C dependent on the electrical polarization of the transistor gate. This dependence is interpreted as due to excitation of two crossed phase-shifted oscillators. A response of the transistor chip (including bonding wires and the substrate) to 100 GHz radiation was numerically simulated. Results of calculations confirmed experimentally observed dependencies and showed that the two oscillators result from an interplay of 100 GHz currents defined by the transistor impedance together with bonding wires and substrate related modes

  9. Development of a homogeneous pulse shape discriminating flow-cell radiation detection system

    International Nuclear Information System (INIS)

    Hastie, K.H.; DeVol, T.A.; Fjeld, R.A.

    1999-01-01

    A homogeneous flow-cell radiation detection system which utilizes coincidence counting and pulse shape discrimination circuitry was assembled and tested with five commercially available liquid scintillation cocktails. Two of the cocktails, Ultima Flo (Packard) and Mono Flow 5 (National Diagnostics) have low viscosities and are intended for flow applications; and three of the cocktails, Optiphase HiSafe 3 (Wallac), Ultima Gold AB (Packard), and Ready Safe (Beckman), have higher viscosities and are intended for static applications. The low viscosity cocktails were modified with 1-methylnaphthalene to increase their capability for alpha/beta pulse shape discrimination. The sample loading and pulse shape discriminator setting were optimized to give the lowest minimum detectable concentration for methylnaphthalenein a 30 s count time. Of the higher viscosity cocktails, Optiphase HiSafe 3 had the lowest minimum detectable activities for alpha and beta radiation, 0.2 and 0.4 Bq/ml for 233 U and 90 Sr/ 90 Y, respectively, for a 30 s count time. The sample loading was 70% and the corresponding alpha/beta spillover was 5.5%. Of the low viscosity cocktails, Mono Flow 5 modified with 2.5% (by volume) 1-methylnaphthalene resulted in the lowest minimum detectable activities for alpha and beta radiation; 0.3 and 0.5 Bq/ml for 233 U and 90 Sr/ 90 Y, respectively, for a 30 s count time. The sample loading was 50%, and the corresponding alpha/beta spillover was 16.6%. HiSafe 3 at a 10% sample loading was used to evaluate the system under simulated flow conditions

  10. Proof-testing strategies induced by dangerous detected failures of safety-instrumented systems

    International Nuclear Information System (INIS)

    Liu, Yiliu; Rausand, Marvin

    2016-01-01

    Some dangerous failures of safety-instrumented systems (SISs) are detected almost immediately by diagnostic self-testing as dangerous detected (DD) failures, whereas other dangerous failures can only be detected by proof-testing, and are therefore called dangerous undetected (DU) failures. Some items may have a DU- and a DD-failure at the same time. After the repair of a DD-failure is completed, the maintenance team has two options: to perform an insert proof test for DU-failure or not. If an insert proof test is performed, it is necessary to decide whether the next scheduled proof test should be postponed or performed at the scheduled time. This paper analyzes the effects of different testing strategies on the safety performance of a single channel of a SIS. The safety performance is analyzed by Petri nets and by approximation formulas and the results obtained by the two approaches are compared. It is shown that insert testing improves the safety performance of the channel, but the feasibility and cost of the strategy may be a hindrance to recommend insert testing. - Highlights: • Identify the tests induced by detected failures. • Model the testing strategies following DD-failures. • Propose analytical formulas for effects of strategies. • Simulate and verify the proposed models.

  11. HPS instrument calibration laboratory accreditation program

    Energy Technology Data Exchange (ETDEWEB)

    Masse, F.X; Eisenhower, E.H.; Swinth, K.L.

    1993-12-31

    The purpose of this paper is to provide an accurate overview of the development and structure of the program established by the Health Physics Society (HPS) for accrediting instrument calibration laboratories relative to their ability to accurately calibrate portable health physics instrumentation. The purpose of the program is to provide radiation protection professionals more meaningful direct and indirect access to the National Institute of Standards and Technology (NIST) national standards, thus introducing a means for improving the uniformity, accuracy, and quality of ionizing radiation field measurements. The process is designed to recognize and document the continuing capability of each accredited laboratory to accurately perform instrument calibration. There is no intent to monitor the laboratory to the extent that each calibration can be guaranteed by the program; this responsibility rests solely with the accredited laboratory.

  12. The Dependence of Cloud Property Trend Detection on Absolute Calibration Accuracy of Passive Satellite Sensors

    Science.gov (United States)

    Shea, Y.; Wielicki, B. A.; Sun-Mack, S.; Minnis, P.; Zelinka, M. D.

    2016-12-01

    Detecting trends in climate variables on global, decadal scales requires highly accurate, stable measurements and retrieval algorithms. Trend uncertainty depends on its magnitude, natural variability, and instrument and retrieval algorithm accuracy and stability. We applied a climate accuracy framework to quantify the impact of absolute calibration on cloud property trend uncertainty. The cloud properties studied were cloud fraction, effective temperature, optical thickness, and effective radius retrieved using the Clouds and the Earth's Radiant Energy System (CERES) Cloud Property Retrieval System, which uses Moderate-resolution Imaging Spectroradiometer measurements (MODIS). Modeling experiments from the fifth phase of the Climate Model Intercomparison Project (CMIP5) agree that net cloud feedback is likely positive but disagree regarding its magnitude, mainly due to uncertainty in shortwave cloud feedback. With the climate accuracy framework we determined the time to detect trends for instruments with various calibration accuracies. We estimated a relationship between cloud property trend uncertainty, cloud feedback, and Equilibrium Climate Sensitivity and also between effective radius trend uncertainty and aerosol indirect effect trends. The direct relationship between instrument accuracy requirements and climate model output provides the level of instrument absolute accuracy needed to reduce climate model projection uncertainty. Different cloud types have varied radiative impacts on the climate system depending on several attributes, such as their thermodynamic phase, altitude, and optical thickness. Therefore, we also conducted these studies by cloud types for a clearer understanding of instrument accuracy requirements needed to detect changes in their cloud properties. Combining this information with the radiative impact of different cloud types helps to prioritize among requirements for future satellite sensors and understanding the climate detection

  13. Split energy level radiation detection

    International Nuclear Information System (INIS)

    Barnes, G.T.

    1986-01-01

    This patent describes an energy discriminating radiation detector comprising: (a) a first element comprising a first material of a kind which is preferentially responsive to penetrative radiation of a first energy range; (b) a second element comprising a second material different in kind from the first material and of a kind which is preferentially responsive to penetrative radiation of second energy range extending higher than the first energy range. The element is positioned to receive radiation which has penetrated through a portion of the first element; and (c) a filter of penetrative radiation interposed between the first and second elements

  14. Preliminary concepts for detecting diversion of LWR spent fuel

    International Nuclear Information System (INIS)

    Sellers, T.A.

    Sandia Laboratories, under the sponsorship of the Department of Energy, Office of Safeguards and Security, has been developing conceptual designs of advanced systems to rapidly detect diversion of LWR spent fuel. Three detection options have been identified and compared on the basis of timeliness of detection and cost. Option 1 is based upon inspectors visiting each facility on a periodic basis to obtain and review data acquired by surveillance instruments and to verify the inventory. Option 2 is based upon continuous inspector presence, aided by surveillance instruments. Option 3 is based upon the collection of data from surveillance instruments with periodic readout either at the facility or at a remote central monitoring and display module and occasional inspection. Surveillance instruments are included in each option to assure a sufficiently high probability of detection. An analysis technique with an example logic tree that was used to identify performance requirements is described. A conceptual design has been developed for Option 3 and the essential hardware elements are not being developed. These elements include radiation, crane and pool acoustic sensors, a Data Collection Module, a Local Collection Module, a Local Display Module and a Central Monitoring and Display Module. A demonstration, in operating facilities, of the overall system concept is planned for the March to June 1979 time frame

  15. Automated System of Area Radiation Measurement (ASARM)

    International Nuclear Information System (INIS)

    Hernandez G, J.

    2013-10-01

    The realized activities in nuclear facilities involve the determination of the presence of ionizing radiation fields in the workspaces. The instruments designed to detect and to measure these radiation fields provide useful information (specific type of radiation, intensity, etc.) to take the appropriate radiological protection measures, with the purpose of reducing to the minimum the workers exposition and the people in general. The radiological protection program of Reactor TRIGA Mark III contains the instructions and procedures to implement a periodic radiological monitoring, surveillance, rising of contamination levels, type and number of the instruments required for the radiological monitoring of areas and personal. The ana logical monitoring system model Rms II used to detect and measuring exposition speed and neutron radiation fields in several areas of the installation, provides the information in a logarithmic scale measurer of 4 or 5 decades located in a shelf where the previously mentioned measurement channels are centralized. Also inside the reactor monitoring system are two monitors of radioactive material concentration in the air: The particles continuous monitor and the gaseous effluents monitor which present the referred information of the diverse detectors through ana logical readers. These monitors when operating with an ana logical indication does not present the possibility to generate historical files electronically of each monitor previously mentioned neither to generate visual and audible indications of the alarms. This work presents the Automated System of Area Radiation Measurement which potentiated the functionality of the area monitors for gamma and neutron radiation, as well as of the particles continuous monitor and the gaseous effluents of reactor TRIGA Mark III, when being developed a computer system that captures in real time the information of all the monitors, generating this way an electronic binnacle, a visual and audible alarm

  16. Radiation survey meters used for environmental monitoring

    International Nuclear Information System (INIS)

    Bjerke, H.; Sigurdsson, T.; Meier Pedersen, K.; Grindborg, J.-E.; Persson, L.; Siiskonen, T.; Hakanen, A.; Kosunen, A.

    2012-01-01

    The Nordic dosimetry group set up the GammaRate project to investigate how its expertise could be used to assure appropriate usage of survey meters in environmental monitoring. Considerable expertise in calibrating radiation instruments exists in the Nordic radiation protection authorities. The Swedish, Finnish, Danish and Norwegian authorities operate Secondary Standard Dosimetry Laboratories (SSDLs) that provide users with calibration traceable to internationally recognised primary standards. These authorities together with the Icelandic authorities have formally cooperated since 2002 in the field of radiation dosimetry. Dosimetry is the base for assesment of risk from ionising radiation and calibration of instruments is an imported part in dosimetry. The Nordic dosimetry group has been focused on cancer therapy. This work extends the cooperation to the dosimetry of radiation protection and environmental monitoring. This report contains the formal, theoretical and practical background for survey meter measurements. Nordic standards dosimetry laboratories have the capability to provide traceable calibration of instruments in various types of radiation. To verify and explore this further in radiation protection applications a set of survey instruments were sent between the five Nordic countries and each of the authority asked to provide a calibration coefficient for all instruments. The measurement results were within the stated uncertainties, except for some results from NRPA for the ionchamber based instrument. The comparison was shown to be a valuable tool to harmonize the calibration of radiation protection instruments in the Nordic countries. Dosimetry plays an important role in the emergency situations, and it is clear that better traceability and harmonised common guidelines will improve the emergency preparedness and health. (Author)

  17. Radiation survey meters used for environmental monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Bjerke, H. (ed.) (Norwegian Radiation Protection Authority, NRPA (Norway)); Sigurdsson, T. (Icelandic Radiation Safety Authority, Geislavarnir Rikisins, GR (IS)); Meier Pedersen, K. (National Board of Health, Statens Institut for Straalebeskyttelse (SIS) (Denmark)); Grindborg, J.-E.; Persson, L. (Swedish Radiation Safety Authority, Straalsaekerhetsmyndigheten (SSM) (Sweden)); Siiskonen, T.; Hakanen, A.; Kosunen, A. (Radiation and Nuclear Safety Authority, Saeteilyturvakeskus (STUK) (Finland))

    2012-01-15

    The Nordic dosimetry group set up the GammaRate project to investigate how its expertise could be used to assure appropriate usage of survey meters in environmental monitoring. Considerable expertise in calibrating radiation instruments exists in the Nordic radiation protection authorities. The Swedish, Finnish, Danish and Norwegian authorities operate Secondary Standard Dosimetry Laboratories (SSDLs) that provide users with calibration traceable to internationally recognised primary standards. These authorities together with the Icelandic authorities have formally cooperated since 2002 in the field of radiation dosimetry. Dosimetry is the base for assesment of risk from ionising radiation and calibration of instruments is an imported part in dosimetry. The Nordic dosimetry group has been focused on cancer therapy. This work extends the cooperation to the dosimetry of radiation protection and environmental monitoring. This report contains the formal, theoretical and practical background for survey meter measurements. Nordic standards dosimetry laboratories have the capability to provide traceable calibration of instruments in various types of radiation. To verify and explore this further in radiation protection applications a set of survey instruments were sent between the five Nordic countries and each of the authority asked to provide a calibration coefficient for all instruments. The measurement results were within the stated uncertainties, except for some results from NRPA for the ionchamber based instrument. The comparison was shown to be a valuable tool to harmonize the calibration of radiation protection instruments in the Nordic countries. Dosimetry plays an important role in the emergency situations, and it is clear that better traceability and harmonised common guidelines will improve the emergency preparedness and health. (Author)

  18. Detecting radiation with your smartphone

    CERN Multimedia

    Agnes Szeberenyi

    2014-01-01

    The winners of the CERN EIROforum Prize in the European Union Competition for Young Scientists 2013 (EUCYS), Michał Gumiela and Rafał Tomasz Kozik from Poland, have just spent an exciting week exploring CERN from 1 to 5 September. The students visited several CERN experiments and facilities and had ample time to interact with scientists on how to improve their invention further.   Michał Gumiela (left) and Rafał Tomasz Kozik (right) with their CERN host, Sabrina El Yacoubi (middle) at the ALICE detector. Michał (21) and Rafał (20) both won a young physicist prize in Poland before submitting their work on “Studies of the applicability of CMOS and CCD sensors for detection of ionising radiation” to the EUCYS competition. “It all started with Fukushima,” recalls Michał. The high school students met in 2011 at a physics workshop, where they started discussing digital photos taken around the Fukushima nuclear plant after the radiation leak. &ldqu...

  19. Present situation and trends in application of isotopes and ionizing radiations in the USSR

    International Nuclear Information System (INIS)

    Shtan, A.S.

    1980-01-01

    New trends of nuclear science and engineering - radiation engineering and radiation technology - have emerged because of the large scale industrial production of artificial radioactive isotopes as well as of the manufacture of electrophysical sources of ionizing radiation. Over 3,500 isotope articles consumed by more than 15,000 enterprises are now manufactured in the USSR. The new trends have subsequently converted into individual branches of the nuclear science and engineering, without which the future technical progress in various fields of industry, medicine, agriculture and scientific research is impossible. Reviewing the situation and trends in the USSR, the following matters are described: tracer method, radiation instrumentation, radiation flaw detection, radiation technology, radiation sterilization, radiation polymerization, radiation modification, radiation and chemical synthesis, food preservation, radiation therapy, radioisotope power engineering. (J.P.N.)

  20. Detection limits by EPR spectroscopy of cumulated doses ionizing radiations in molluscs shells

    International Nuclear Information System (INIS)

    Ostrowski, K.; Burlinska, G.; Dziedzic-Goclawska, A.; Stachowicz, W.; Michalik, J.; Sadlo, J.

    1997-01-01

    The exposure of waters to ionizing radiation from radionuclides stored in concrete containers or freed in nuclear accidents or underwater eruption might be difficult to be proved, when currents, rains, exchange of water displace sand soils or rocks in the bottom. Ionizing radiation evokes stable paramagnetic centers in the crystalline lattice of mineral components in bones as well as in exoskeletons of most molluscs, which are detected by the EPR spectroscopy and could be used as an indicator of the exposure to the action of radiation during prolonged period of time. (authors)

  1. Foundations of ionizing radiation dosimetry

    International Nuclear Information System (INIS)

    Denisenko, O.N.; Pereslegin, I.A.

    1985-01-01

    Foundations of dosimetry in application to radiotherapy are presented. General characteristics of ionizing radiations and main characteristics of ionizing radiation sources, mostly used in radiotherapy, are given. Values and units for measuring ionizing radiation (activity of a radioactive substance, absorbed dose, exposure dose, integral dose and dose equivalent are considered. Different methods and instruments for ionizing radiation dosimetry are discussed. The attention is paid to the foundations of clinical dosimetry (representation of anatomo-topographic information, choice of radiation conditions, realization of radiation methods, corrections for a configuration and inhomogeneity of a patient's body, account of biological factors of radiation effects, instruments of dose field formation, control of irradiation procedure chosen)

  2. CERES Top-of-Atmosphere Earth Radiation Budget Climate Data Record: Accounting for in-Orbit Changes in Instrument Calibration

    Directory of Open Access Journals (Sweden)

    Norman G. Loeb

    2016-02-01

    Full Text Available The Clouds and the Earth’s Radiant Energy System (CERES project provides observations of Earth’s radiation budget using measurements from CERES instruments onboard the Terra, Aqua and Suomi National Polar-orbiting Partnership (S-NPP satellites. As the objective is to create a long-term climate data record, it is necessary to periodically reprocess the data in order to incorporate the latest calibration changes and algorithm improvements. Here, we focus on the improvements and validation of CERES Terra and Aqua radiances in Edition 4, which are used to generate higher-level climate data products. Onboard sources indicate that the total (TOT channel response to longwave (LW radiation has increased relative to the start of the missions by 0.4% to 1%. In the shortwave (SW, the sensor response change ranges from −0.4% to 0.6%. To account for in-orbit changes in SW spectral response function (SRF, direct nadir radiance comparisons between instrument pairs on the same satellite are made and an improved wavelength dependent degradation model is used to adjust the SRF of the instrument operating in a rotating azimuth plane scan mode. After applying SRF corrections independently to CERES Terra and Aqua, monthly variations amongst these instruments are highly correlated and the standard deviation in the difference of monthly anomalies is 0.2 Wm−2 for ocean and 0.3 Wm−2 for land/desert. Additionally, trends in CERES Terra and Aqua monthly anomalies are consistent to 0.21 Wm−2 per decade for ocean and 0.31 Wm−2 per decade for land/desert. In the LW, adjustments to the TOT channel SRF are made to ensure that removal of the contribution from the SW portion of the TOT channel with SW channel radiance measurements during daytime is consistent throughout the mission. Accordingly, anomalies in day–night LW difference in Edition 4 are more consistent compared to Edition 3, particularly for the Aqua land/desert case.

  3. Development of front-end ASIC for radiation detection and measurement

    International Nuclear Information System (INIS)

    Shimazoe, K.

    2014-01-01

    For realizing the multichannel spectroscopy of gamma rays, the technology of integrated circuits is necessary. Multi-channel gamma ray spectroscopy is very important for many applications including the medical imaging and the environmental monitoring. The current progress in the development of application specific integrated circuit (ASIC) for multi-channel radiation detection is introduced and reviewed. (author)

  4. Electronics for radiation detection

    CERN Document Server

    2011-01-01

    Addresses the developments in the design of semiconductor detectors and integrated circuits, in the context of medical imaging using ionizing radiation. This book explains how circuits for radiation are built, focusing on practical information about how they are being used, rather than mathematical details.

  5. ITRAP - International laboratory and field test site exercise for radiation detection instruments and monitoring systems at border crossings

    International Nuclear Information System (INIS)

    Beck, P.; Schmitzer, C.; Duftschmid, K.E.; Arlt, R.

    2001-01-01

    Illicit trafficking in nuclear materials has become more and more a problem, due to the circulation of a high number of radioactive sources and the big amount of nuclear material. The IAEA database counts at present more than 300 verified cases. The endangering cased thereby ranges from possible health defect for the publication to terrorists activities and production of nuclear weapons. In addition to the primary criminal reasons the illegal disposal of radioactive sources as salvage, scrap and others show a further problem, which has lead to severe accidents and lethal effects in the past (e.g. Goiana, Mexico). Some countries have already under taken countermeasures (e.g. Monitoring at the Finnish-Russian and German- Polish border, border monitoring in Italy). The International Atomic Energy Agency (IAEA) has reacted on this actual problem by setting up a new program to fight against nuclear criminality and has suggested a pilot study for the practical test of border monitoring systems. Co-ordinated by the Federal Ministry of Economy and Labour the Austrian Government financed the pilot study ITRAP (Illicit Trafficking Radiation Detection Assessment Program) carried out by the Austrian Research Centers Seibersdorf (ARCS). Aim of the study was to work out the technical requirements and the practicability of an useful monitoring system at border crossings. The results of the study will be offered by the IAEA to the member states as international recommendations for border monitoring systems

  6. R-B measurements and their implications : solar UV radiation trends

    International Nuclear Information System (INIS)

    Basher, R.

    1993-01-01

    There is a wide variety of needs for UV information, including: (i) real-time monitoring and other public information; (ii) trend detection and policy-maker needs; (iii) space/time/wavelength information for health and biological impacts research; and (iv) atmospheric research, e.g. effects of clouds on UV, transmission model development, etc. The way each need is satisfied will vary. High quality spectral data for research purposes requires expensive equipment and close, on-site scientific supervision and hence will be restricted to a few locations, while conversely, measurements of spatial patterns will require numerous simple instruments, such a the Robertson-Berger Meter or International Light instrument, or the use of satellite methods. Trend detection will lay great store on long-term stability of instrumentation. It is important to recognise that to deal with the variety of needs, we need the combined use of spectral measurement, broadband measurement, radiation modelling, and satellite techniques. (author). 13 refs., 3 figs

  7. ACRF Instrumentation Status: New, Current, and Future January 2007

    Energy Technology Data Exchange (ETDEWEB)

    Liljegren, JC

    2007-01-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Program Climate Research Facility instrumentation status. The report is divided into four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development.

  8. ACRF Instrumentation Status: New, Current, and Future October 2006

    Energy Technology Data Exchange (ETDEWEB)

    JC Liljegren

    2006-10-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Program Climate Research Facility instrumentation status. The report is divided into four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development.

  9. ACRF Instrumentation Status: New, Current, and Future May 2007

    Energy Technology Data Exchange (ETDEWEB)

    JC Liljegren

    2007-05-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Program Climate Research Facility instrumentation status. The report is divided into four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development.

  10. ACRF Instrumentation Status: New, Current, and Future February 2007

    Energy Technology Data Exchange (ETDEWEB)

    JC Liljegren

    2007-02-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Program Climate Research Facility instrumentation status. The report is divided into four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development

  11. ACRF Instrumentation Status: New, Current, and Future May 2007

    Energy Technology Data Exchange (ETDEWEB)

    JC Liljegren

    2007-04-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Program Climate Research Facility instrumentation status. The report is divided into four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development.

  12. ACRF Instrumentation Status: New, Current, and Future March 2007

    Energy Technology Data Exchange (ETDEWEB)

    JC Liljegren

    2007-03-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Program Climate Research Facility instrumentation status. The report is divided into four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development.

  13. ACRF Instrumentation Status: New, Current, and Future - February 2008

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2008-03-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development.

  14. ACRF Instrumentation Status: New, Current, and Future - March 2008

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2008-04-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development.

  15. Detection of radiation-induced hydrocarbons in baked sponge cake prepared with irradiated liquid egg

    International Nuclear Information System (INIS)

    Schulzki, G.; Spiegelberg, A.; Boegl, K.W.; Schreiber, G.A.

    1995-01-01

    For identification of irradiated food, radiation-induced volatile hydrocarbons (HC) are determined by gas chromatography in the non-polar fraction of fat. However, in complex food matrices the detection is often disturbed by fat-associated compounds. On-line coupling of high performance liquid chromatography (LC) and gas chromatography (GC) is very efficient to remove such compounds from the HC fraction. The high sensitivity of this fast and efficient technique is demonstrated by the example of detection of radiation-induced HC in fat isolated from baked sponge cake which had been prepared with irradiated liquid egg. (Author)

  16. Design of and initial results from a Highly Instrumented Reactor for Atmospheric Chemistry (HIRAC

    Directory of Open Access Journals (Sweden)

    D. R. Glowacki

    2007-10-01

    Full Text Available The design of a Highly Instrumented Reactor for Atmospheric Chemistry (HIRAC is described and initial results obtained from HIRAC are presented. The ability of HIRAC to perform in-situ laser-induced fluorescence detection of OH and HO2 radicals with the Fluorescence Assay by Gas Expansion (FAGE technique establishes it as internationally unique for a chamber of its size and pressure/temperature variable capabilities. In addition to the FAGE technique, HIRAC features a suite of analytical instrumentation, including: a multipass FTIR system; a conventional gas chromatography (GC instrument and a GC instrument for formaldehyde detection; NO/NO2, CO, O3, and H2O vapour analysers. Ray tracing simulations and NO2 actinometry have been utilized to develop a detailed model of the radiation field within HIRAC. Comparisons between the analysers and the FTIR coupled to HIRAC have been performed, and HIRAC has also been used to investigate pressure dependent kinetics of the chlorine atom reaction with ethene and the reaction of O3 and t-2-butene. The results obtained are in good agreement with literature recommendations and Master Chemical Mechanism predictions. HIRAC thereby offers a highly instrumented platform with the potential for: (1 high precision kinetics investigations over a range of atmospheric conditions; (2 detailed mechanism development, significantly enhanced according to its capability for measuring radicals; and (3 field instrument intercomparison, calibration, development, and investigations of instrument response at a range of atmospheric conditions.

  17. USB-based radiation monitor

    International Nuclear Information System (INIS)

    Drndarevic, V.; Jevtic, N.; Djuric, R.

    2006-01-01

    The Universal Serial Bus has become a dominant interface for the connection of standard peripheral devices to a personal computer. This paper analyzes the possibilities of USB bus applications in the field of measurement and environmental monitoring. As a result, a gamma radiation monitor consisting of an USB-based universal peripheral device and a gamma probe with a GM counter, has been designed. For the interfacing monitor with the powerful and easy to use LabVIEW software package, an instrument driver as a set of virtual instruments has been developed. The proposed monitor is a flexible instrument which can be used for laboratory measurements, as an environmental radiation monitor or for training purposes. Connected to the laptop computer, the monitor becomes a portable instrument suitable for field measurements. Basic measurements and functionality properties of the radiation monitor are presented here

  18. Experimental applications for the MARK-1 and MARK-1A pulsed ionizing radiation detection systems. Volume 3

    International Nuclear Information System (INIS)

    Harker, Y.D.; Lawrence, R.S.; Yoon, W.Y.; Lones, J.L.

    1993-12-01

    This report is the third volume in a three volume set describing the MARK series of pulsed ionizing radiation detection systems. This volume describes the MARK-1A detection system, compares it with the MARK-1 system, and describes the experimental testing of the detection systems. Volume 1 of this set presents the technical specifications for the MARK-1 detection system. Volume 2 is an operations manual specifically for the MARK-1 system, but it generally applies to the MARK-1A system as well. These detection systems operate remotely and detect photon radiation from a single or a multiple pulsed source. They contain multiple detector (eight in the MARK-1 and ten in the MARK-1A) for determination of does and incident photon effective energy. The multiple detector arrangement, having different detector sizes and shield thicknesses, provides the capability of determining the effective photon energy of the radiation spectrum. Dose measurements using these units are consistent with TLD measurements. The detection range is from 3 nanorads to 90 microrads per source burst; the response is linear over that range. Three units were built and are ready for field deployment

  19. AN IMAGE-ANALYSIS TECHNIQUE FOR DETECTION OF RADIATION-INDUCED DNA FRAGMENTATION AFTER CHEF ELECTROPHORESIS

    NARCIS (Netherlands)

    ROSEMANN, M; KANON, B; KONINGS, AWT; KAMPINGA, HH

    CHEF-electrophoresis was used as a technique to detect radiation-induced DNA breakage with special emphasis to biological relevant X-ray doses (0-10 Gy). Fluorescence detection of DNA-fragments using a sensitive image analysis system was directly compared with conventional scintillation counting of

  20. FISH as A method for detection of radiation Induced genetic damage

    International Nuclear Information System (INIS)

    Lakatosova, M.; Holeckova, B.

    2006-01-01

    Fluorescence in situ hybridization (FISH) has been considered as a suitable method for rapid and easy detection of chromosome aberrations. In contrast to the standard conventional staining procedure, this technique enables the detection and specification of stable chromosomal re-arrangements, which are compatible with cellular division and thus, they could be transmitted from common ancestral to next cell generations. FISH chromosome - specific painting probes have been effectively applied for the detection of chromosomal damage after exposure to radiation. During last years, several specific fluorescent labeled probes were performed that allowed precise detection of centromeres, sub-telomeres or other regions (sequences) in genome. Our paper deals with describing of different types of FISH probes and their possibilities for application in radiobiology. (authors)