WorldWideScience

Sample records for radiation desensitivity bracket

  1. Influence of bleaching and desensitizing gel on bond strength of orthodontic brackets

    Directory of Open Access Journals (Sweden)

    Fernanda Alves Rodrigues Britto

    2015-04-01

    Full Text Available OBJECTIVE: The objective of this study was to assess, in vitro, the influence of bleaching gel and the use of desensitizing agent over bond strength of ceramic brackets bonded to bovine enamel. METHODS: One hundred bovine incisors were selected and randomly divided into five groups (n = 20: Group 1, control group (without bleaching; Group 2, bleached with 35% hydrogen peroxide; Group 3, bleached with 35% hydrogen peroxide (three applications, 15 minutes each and desensitizing agent applied for 10 minutes; Group 4, bleached with 35% hydrogen peroxide for 40 minutes; Group 5, bleached with 35% hydrogen peroxide for 40 minutes with desensitizing agent applied for 10 minutes. Brackets were bonded 7 days after bleaching and submitted to shear bond strength test after 24 hours at a compression rate of 1 mm/minute. After fracture, the adhesive remnant index (ARI was assessed under stereoscopic at 40 x magnification. Shear strength data (MPa were submitted to one-way ANOVA and Tukey's test with significance level set at 5%. RESULTS: Group 5 (29.33 MPa showed significantly higher bond strength than Group 1 (19.19 MPa, Group 2 (20.59 MPa and Group 4 (23.25 MPa, but with no difference in comparison to Group 3. There was no significant difference among the other groups. The adhesive remnant index showed predominance of score 3, that is, all resin remained adhered to enamel for all groups. CONCLUSION: Bleaching with 35% hydrogen peroxide with calcium associated with desensitizing agent application produced higher bond strength values of brackets bonded to bovine enamel.

  2. Bracket debonding by mid-infrared laser radiation

    International Nuclear Information System (INIS)

    Jelínková, H; Šulc, J; Koranda, P; Němec, M; Dostálová, T; Hofmanova, P

    2009-01-01

    The purpose of the study was to determine the proper laser radiation for ceramic bracket debonding and the investigation of the tooth root temperature injury. The debonding was investigated by diode-pumped continuously running Tm:YAP and Nd:YAG lasers, and by GaAs laser diode generating radiation with the wavelengths 1.997 μm, 1.444 μm, and 0.808 μm, respectively. The possibility of brackets removal by laser radiation was investigated together with the tooth and, it specifically, root temperature rise. From the results it follows that continuously running diode pumped Tm:YAG or Nd:YAG laser generating wavelengths 1.997 μm or 1.444 μm, respectively, having the output power 1 W can be good candidates for ceramic brackets debonding

  3. Radiation-induced segregation in desensitized type 304 austenitic stainless steel

    International Nuclear Information System (INIS)

    Ahmedabadi, Parag; Kain, V.; Arora, K.; Samajdar, I.; Sharma, S.C.; Bhagwat, P.

    2011-01-01

    Graphical abstract: Schematic representation of overall experimental and results, indicating attack, after the DL-EPR test, on grain boundaries, twin boundaries and pit-like features within grains at the depth of maximum attack. The sensitized specimen also showed severe attack on grain boundaries, however, attack on twin-boundaries and pit-like features were not noticed. Display Omitted Highlights: → Characterization of radiation-induced segregation done by EPR and AFM examination. → Cr depletion adjacent to carbides due to RIS in irradiated desensitized 304 SS. → Effectiveness as defect sink: twins > pit-like features > grain boundary. - Abstract: Radiation-induced segregation (RIS) in desensitized type 304 stainless steel (SS) was investigated using a combination of electrochemical potentiokinetic reactivation (EPR) test and atomic force microscopy (AFM). Desensitized type 304 SS was irradiated to 0.43 dpa (displacement per atom) using 4.8 MeV protons at 300 deg. C. The maximum attack in the EPR test for the irradiated desensitized SS was measured at a depth of 70 μm from the surface. Grain boundaries and twin boundaries got attacked and pit-like features within the grains were observed after the EPR test at the depth of 70 μm. The depth of attack, as measured by AFM, was higher at grain boundaries and pit-like features as compared to twin boundaries. It has been shown that the chromium depletion due to RIS takes place at the carbide-matrix as well as at the carbide-carbide interfaces at grain boundaries. The width of attack at grain boundaries after the EPR test of the irradiated desensitized specimen appeared larger due to the dislodgement of carbides at grain boundaries.

  4. Radiation-induced segregation in desensitized type 304 austenitic stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Ahmedabadi, Parag, E-mail: adit@barc.gov.in [Materials Science Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400 085 (India); Kain, V. [Materials Science Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400 085 (India); Arora, K. [PEC University of Technology, Chandigarh (India); Samajdar, I. [Department of Metallurgical Engineering and Materials Science, Indian Institute Technology Bombay, Powai, Mumbai 400 076 (India); Sharma, S.C.; Bhagwat, P. [Nuclear Physics Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400 085 (India)

    2011-09-30

    Graphical abstract: Schematic representation of overall experimental and results, indicating attack, after the DL-EPR test, on grain boundaries, twin boundaries and pit-like features within grains at the depth of maximum attack. The sensitized specimen also showed severe attack on grain boundaries, however, attack on twin-boundaries and pit-like features were not noticed. Display Omitted Highlights: > Characterization of radiation-induced segregation done by EPR and AFM examination. > Cr depletion adjacent to carbides due to RIS in irradiated desensitized 304 SS. > Effectiveness as defect sink: twins > pit-like features > grain boundary. - Abstract: Radiation-induced segregation (RIS) in desensitized type 304 stainless steel (SS) was investigated using a combination of electrochemical potentiokinetic reactivation (EPR) test and atomic force microscopy (AFM). Desensitized type 304 SS was irradiated to 0.43 dpa (displacement per atom) using 4.8 MeV protons at 300 deg. C. The maximum attack in the EPR test for the irradiated desensitized SS was measured at a depth of 70 {mu}m from the surface. Grain boundaries and twin boundaries got attacked and pit-like features within the grains were observed after the EPR test at the depth of 70 {mu}m. The depth of attack, as measured by AFM, was higher at grain boundaries and pit-like features as compared to twin boundaries. It has been shown that the chromium depletion due to RIS takes place at the carbide-matrix as well as at the carbide-carbide interfaces at grain boundaries. The width of attack at grain boundaries after the EPR test of the irradiated desensitized specimen appeared larger due to the dislodgement of carbides at grain boundaries.

  5. Desensitization with oxaliplatin in patients intolerant of carboplatin desensitization.

    Science.gov (United States)

    Rose, Peter G; Metz, Carol; Link, Nicolas

    2014-11-01

    The tolerance and efficacy of oxaliplatin desensitization in patients who were intolerant of carboplatin desensitization were determined. We retrospectively reviewed the Gynecologic Oncology patients who received carboplatin or oxaliplatin from December 2007 until August 2014. The number of treatments and number of patients of carboplatin standard infusions, carboplatin desensitizations, and oxaliplatin desensitizations were determined. Carboplatin infusions (2294) were administered to 281 patients. Twenty-eight (10%) of these patients developed carboplatin hypersensitivity and were treated with 205 carboplatin desensitizations. Nine (29%) patients were subsequently treated with 61 oxaliplatin desensitizations due to intolerance of carboplatin desensitization. Nine of the 10 patients tolerated this infusion well. Four of 9 evaluable patients had an objective response, 2 complete and 2 partial. Oxaliplatin desensitization seems well tolerated and effective in most patients who are intolerant of carboplatin desensitization.

  6. RF and dc desensitized electroexplosive device

    Science.gov (United States)

    Krainiak, John W.; Speaks, Paul D.; Cornett, Michael S.

    1989-07-01

    This patent application relates to electroexplosive devices (EEDs) such as detonators, blasting caps and squibs, in particular to a method and device for desensitizing EEDs to electromagnetic radiation and electrostatic charges with the added ability to desensitize the device to essentially dc currents. An insensitive electroexplosive device to electrically ignite explosive is disclosed. This device is inherently immune to radio frequency (RF) radiation, and also provides protection against dc or very low frequency RF induced by arcing. A central feature is use of zeners and capacitors to form a reactively balanced bridge circuit. When constructed in semiconductor form, as described in this application, the device is capable of incorporation in small caliber ordnance.

  7. Single interval longwave radiation scheme based on the net exchanged rate decomposition with bracketing

    Czech Academy of Sciences Publication Activity Database

    Geleyn, J.- F.; Mašek, Jan; Brožková, Radmila; Kuma, P.; Degrauwe, D.; Hello, G.; Pristov, N.

    2017-01-01

    Roč. 143, č. 704 (2017), s. 1313-1335 ISSN 0035-9009 R&D Projects: GA MŠk(CZ) LO1415 Institutional support: RVO:86652079 Keywords : numerical weather prediction * climate models * clouds * parameterization * atmospheres * formulation * absorption * scattering * accurate * database * longwave radiative transfer * broadband approach * idealized optical paths * net exchanged rate decomposition * bracketing * selective intermittency Subject RIV: DG - Athmosphere Sciences, Meteorology OBOR OECD: Meteorology and atmospheric sciences Impact factor: 3.444, year: 2016

  8. Lazy & quarrelsome brackets

    OpenAIRE

    Visser, A.

    1992-01-01

    In this paper we study two (kinds of) systems of brackets in an algebraic way. Lazy brackets have the same effect as introducing or eliminating 'a sufficient amount' of ordinary brackets at the same time. Quarrelsome brackets are brackets corresponding to different types of 'levels': think e.g. of term levels versus sentence levels. A modest framework is proposed to study these kinds of brackets simultaneously.

  9. Lazy & quarrelsome brackets

    NARCIS (Netherlands)

    Visser, A.

    1992-01-01

    In this paper we study two (kinds of) systems of brackets in an algebraic way. Lazy brackets have the same effect as introducing or eliminating 'a sufficient amount' of ordinary brackets at the same time. Quarrelsome brackets are brackets corresponding to different types of 'levels': think

  10. A comparative study of frictional force in self-ligating brackets according to the bracket-archwire angulation, bracket material, and wire type

    Science.gov (United States)

    Lee, Souk Min

    2015-01-01

    Objective This study aimed to compare the frictional force (FR) in self-ligating brackets among different bracket-archwire angles, bracket materials, and archwire types. Methods Passive and active metal self-ligating brackets and active ceramic self-ligating brackets were included as experimental groups, while conventional twin metal brackets served as a control group. All brackets were maxillary premolar brackets with 0.022 inch [in] slots and a -7° torque. The orthodontic wires used included 0.018 round and 0.019 × 0.025 in rectangular stainless steel wires. The FR was measured at 0°, 5°, and 10° angulations as the wire was drawn through the bracket slots after attaching brackets from each group to the universal testing machine. Static and kinetic FRs were also measured. Results The passive self-ligating brackets generated a lower FR than all the other brackets. Static and kinetic FRs generally increased with an increase in the bracket-archwire angulation, and the rectangular wire caused significantly higher static and kinetic FRs than the round wire (p brackets exhibited the lowest static FR at the 0° angulation and a lower increase in static and kinetic FRs with an increase in bracket-archwire angulation than the other brackets, while the conventional twin brackets showed a greater increase than all three experimental brackets. Conclusions The passive self-ligating brackets showed the lowest FR in this study. Self-ligating brackets can generate varying FRs in vitro according to the wire size, surface characteristics, and bracket-archwire angulation. PMID:25667913

  11. Effect of delayed polymerization time and bracket manipulation on orthodontic bracket bonding

    Science.gov (United States)

    Ponikvar, Michael J.

    This study examined the effect of bracket manipulation in combination with delayed polymerization times on orthodontic bracket shear bond strength and degree of resin composite conversion. Orthodontics brackets were bonded to extracted third molars in a simulated oral environment after a set period of delayed polymerization time and bracket manipulation. After curing the bracket adhesive, each bracket underwent shear bond strength testing followed by micro-Raman spectroscopy analysis to measure the degree of conversion of the resin composite. Results demonstrated the shear bond strength and the degree of conversion of ceramic brackets did not vary over time. However, with stainless steel brackets there was a significant effect (p ≤ 0.05) of delay time on shear bond strength between the 0.5 min and 10 min bracket groups. In addition, stainless steel brackets showed significant differences related to degree of conversion over time between the 0.5 min and 5 min groups, in addition to the 0.5 min and 10 min groups. This investigation suggests that delaying bracket adhesive polymerization up to a period of 10 min then adjusting the orthodontic bracket may increase both shear bond strength and degree of conversion of stainless steel brackets while having no effect on ceramic brackets.

  12. Motivational Goal Bracketing

    DEFF Research Database (Denmark)

    Nafziger, Julia; Koch, Alexander

    It is a puzzle why people often evaluate consequences of choices separately (narrow bracketing) rather than jointly (broad bracketing). We study the hypothesis that a present-biased individual, who faces two tasks, may bracket his goals narrowly for motivational reasons. Goals motivate because th...... of the tasks. Narrow goals have a stronger motivational force and thus can be optimal. In particular, if one task outcome becomes known before working on the second task, narrow bracketing is always optimal.......It is a puzzle why people often evaluate consequences of choices separately (narrow bracketing) rather than jointly (broad bracketing). We study the hypothesis that a present-biased individual, who faces two tasks, may bracket his goals narrowly for motivational reasons. Goals motivate because...

  13. Active, Passive, and Vicarious Desensitization

    Science.gov (United States)

    Denney, Douglas R.

    1974-01-01

    Two variations of desensitization therapy for reducing test anxiety were studied, active desensitization in which the client describes his visualizations of the scenes and vicarious desensitization in which the client merely observes the desensitization treatment of another test anxious client. The relaxation treatment which emphasized application…

  14. Torque expression in self-ligating orthodontic brackets and conventionally ligated brackets: A systematic review.

    Science.gov (United States)

    Al-Thomali, Yousef; Mohamed, Roshan-Noor; Basha, Sakeenabi

    2017-01-01

    To evaluate the torque expression of self ligating (SL) orthodontic brackets and conventionally ligated brackets and the torque expression in active and passive SL brackets. Our systematic search included MEDLINE, EMBASE, CINAHL, PsychINFO, Scopus, and key journals and review articles; the date of the last search was April 4th 2016. We graded the methodological quality of the studies by means of the Quality Assessment Tool for Quantitative Studies, developed for the Effective Public Health Practice Project (EPHPP). In total, 87 studies were identified for screening, and 9 studies were eligible. The quality assessment rated one of the study as being of strong quality, 7 (77.78%) of these studies as being of moderate quality. Three out of 7 studies which compared SL and conventionally ligated brackets showed, conventionally ligated brackets with highest torque expression compared to SL brackets. Badawi showed active SL brackets with highest torque expression compared to passive SL brackets. Major and Brauchli showed no significant differences in torque expression of active and passive SL brackets. Conventionally ligated brackets presented with highest torque expression compared to SL brackets. Minor difference was recorded in a torque expression of active and passive SL brackets. Key words: Systematic review, self ligation, torque expression, conventional ligation.

  15. Frictional resistance of self-ligating versus conventional brackets in different bracket-archwire-angle combinations

    Science.gov (United States)

    MONTEIRO, Maria Regina Guerra; da SILVA, Licinio Esmeraldo; ELIAS, Carlos Nelson; VILELLA, Oswaldo de Vasconcellos

    2014-01-01

    Objective To compare the influence of archwire material (NiTi, beta-Ti and stainless steel) and brackets design (self-ligating and conventional) on the frictional force resistance. Material and Methods Two types of brackets (self-ligating brackets - Smartclip, 3M/Unitek - and conventional brackets - Gemini, 3M/Unitek) with three (0, 5, and 10 degrees) slot angulation attached with elastomeric ligatures (TP Orthodontics) were tested. All brackets were tested with archwire 0.019"x0.025" nickel-titanium, beta-titanium, and stainless steel (Unitek/3M). The mechanical testing was performed with a universal testing machine eMIC DL 10000 (eMIC Co, Brazil). The wires were pulled from the bracket slots at a cross-head speed of 3 mm/min until 2 mm displacement. Results Self-ligating brackets produced significantly lower friction values compared with those of conventional brackets. Frictional force resistance values were directly proportional to the increase in the bracket/ wire angulation. With regard to conventional brackets, stainless steel wires had the lowest friction force values, followed by nickel-titanium and beta-titanium ones. With regard to self-ligating brackets, the nickel-titanium wires had the lowest friction values, significantly lower than those of other materials. Conclusion even at different angulations, the self-ligating brackets showed significantly lower friction force values than the conventional brackets. Combined with nickel-titanium wires, the self-ligating brackets exhibit much lower friction, possibly due to the contact between nickel-titanium clips and wires of the same material. PMID:25025564

  16. Frictional resistance of self-ligating versus conventional brackets in different bracket-archwire-angle combinations

    Directory of Open Access Journals (Sweden)

    Maria Regina Guerra MONTEIRO

    2014-06-01

    Full Text Available Objective: To compare the influence of archwire material (NiTi, beta-Ti and stainless steel and brackets design (self-ligating and conventional on the frictional force resistance. Material and Methods: Two types of brackets (self-ligating brackets - Smartclip, 3M/Unitek - and conventional brackets - Gemini, 3M/Unitek with three (0, 5, and 10 degrees slot angulation attached with elastomeric ligatures (TP Orthodontics were tested. All brackets were tested with archwire 0.019"x0.025" nickel-titanium, beta-titanium, and stainless steel (Unitek/3M. The mechanical testing was performed with a universal testing machine eMIC DL 10000 (eMIC Co, Brazil. The wires were pulled from the bracket slots at a cross-head speed of 3 mm/min until 2 mm displacement. Results: Self-ligating brackets produced significantly lower friction values compared with those of conventional brackets. Frictional force resistance values were directly proportional to the increase in the bracket/ wire angulation. With regard to conventional brackets, stainless steel wires had the lowest friction force values, followed by nickel-titanium and beta-titanium ones. With regard to self-ligating brackets, the nickel-titanium wires had the lowest friction values, significantly lower than those of other materials. Conclusion: even at different angulations, the self-ligating brackets showed significantly lower friction force values than the conventional brackets. Combined with nickel-titanium wires, the self-ligating brackets exhibit much lower friction, possibly due to the contact between nickel-titanium clips and wires of the same material.

  17. Desensitization to rituximab in a multidisciplinary setting.

    Science.gov (United States)

    Amorós-Reboredo, Patrícia; Sánchez-López, Jaime; Bastida-Fernández, Carla; do Pazo-Oubiña, Fernando; Borràs-Maixenchs, Núria; Giné, Eva; Valero, Antonio; Creus-Baró, Natàlia

    2015-10-01

    The need to offer first-line therapy to the increasing number of patients who have suffered an hypersensitivity reaction has stimulated the use of rapid desensitization protocols. To present our experience working as a multidisciplinary team using a rituximab rapid desensitization scheme. Patient demographics, allergic reaction, skin tests to rituximab, number of desensitizations, reactions during the desensitization protocol and actions taken, number of administered and completed cycles, were retrospectively collected in patients who received at least one desensitization to rituximab. Number of desensitizations successfully managed. Between 2012 and June 2013 five patients received a total of 19 desensitizations to rituximab using a 12 step rapid desensitization protocol. All patients received the scheduled chemotherapeutic cycles as inpatients, with no delay in administration dates. Three patients presented a hypersensitivity reaction during the first desensitization and in one patient the event occurred again during the second treatment cycle. All reactions occurred in the last step, when the infusion rate reached the maximum speed. The developed protocol for rapid desensitization was successful in five patients receiving rituximab. Patients could receive the full intended dose.

  18. In Vivo Desensitization: An Alternative to Systematic Desensitization with College Students

    Science.gov (United States)

    Atkinson, Donald R.

    1973-01-01

    It is the thesis of this article that college counselors would make more economical and efficacious use of their time and would greatly reduce the risk of turning off'' students if they employed in vivo desensitization rather than systematic desensitization when dealing with anxious clients. (Author)

  19. Universal Cable Brackets

    Science.gov (United States)

    Vanvalkenburgh, C.

    1985-01-01

    Concept allows routing easily changed. No custom hardware required in concept. Instead, standard brackets cut to length and installed at selected locations along cable route. If cable route is changed, brackets simply moved to new locations. Concept for "universal" cable brackets make it easy to route electrical cable around and through virtually any structure.

  20. Systematic Desensitization and the Reduction of Anxiety.

    Science.gov (United States)

    Deffenbacher, Jerry L.; Suinn, Richard M.

    1988-01-01

    Provides detailed information on systematic desensitization, describing in detail the procedures of imaginal desensitization. Briefly describes variants of group, in vivo, massed, and self-administered desensitization. Outlines guidelines for appropriate selection and use of desensitization and presents sampling of research findings with diversity…

  1. Generalized Moshinsky bracket recurrence relations

    International Nuclear Information System (INIS)

    Bevelacqua, J.J.

    1979-01-01

    Recurrence relations for generalized Talmi-Moshinsky brackets are derived. These relations permit the generation of transformation brackets once appropriate starting brackets are determined. The savings in computer time, when compared with generating brackets individually, is at least a factor of 10 for brackets with radial quantum numbers as large as 9 and angular quantum numbers as large as 2. (author)

  2. A-KAM, bracket positioning device

    Directory of Open Access Journals (Sweden)

    Anand Ambekar

    2018-01-01

    Full Text Available Bracket positioning is the heart of preadjusted edgewise appliance. Accuracy of bracket positioning directly affects the treatment outcome. A number of hand-held instruments are available for bracket positioning accuracy including Boon's gauge, MBT gauges, and various other modifications. However, the most commonly used MBT gauges come in a set of two or four jigs with gauges on each end of the instrument making it difficult to carry in the instrument tray for the orthodontists. Our new bracket positioning instrument, A-KAM, bracket positioning device surpasses these difficulties and can be used for reproducible bracket placement from 2.5 mm to 5.5 mm from the base of bracket.

  3. [Friction: self-ligating brackets].

    Science.gov (United States)

    Thermac, Guilhem; Morgon, Laurent; Godeneche, Julien

    2008-12-01

    The manufacturers of self-ligating brackets advertise a reduction of the friction engendered between the wire and the bracket, which is an essential parameter for treatment's speed and comfort. We have compared the friction obtained with four types of self-ligating brackets - In-Ovation R, Damon 3, Smart Clip and Quick - with that of a standard bracket Omniarch associated with an elastomeric ligature. All bracket were tested on a bench of traction with three types of wires: steel .019"x.025", TMA .019"x.025" and NEO sentalloy F300 .020"x.020". The results confirm a clear friction reduction for all tested wire.

  4. Effectiveness of oxaliplatin desensitization protocols.

    Science.gov (United States)

    Cortijo-Cascajares, Susana; Nacle-López, Inmaculada; García-Escobar, Ignacio; Aguilella-Vizcaíno, María José; Herreros-de-Tejada, Alberto; Cortés-Funes Castro, Hernán; Calleja-Hernández, Miguel-Ángel

    2013-03-01

    Hypersensitivity reaction (HSR) to antineoplastic drugs can force doctors to stop treatment and seek other alternatives. These alternatives may be less effective, not as well tolerated and/or more expensive. Another option is to use desensitization protocols that induce a temporary state of tolerance by gradually administering small quantities of the antineoplastic drug until the therapeutic dosage is reached. The aim of this study is to assess the effectiveness of oxaliplatin desensitization protocols. A retrospective observational study was carried out between January 2006 and May 2011. The inclusion criteria were patients undergoing chemotherapy treatment with oxaliplatin who had developed an HSR to the drug and who were candidates for continuing the treatment using a desensitization protocol. The patients' clinical records were reviewed and variables were gathered relating to the patient, the treatment, the HSR, and the desensitization protocol administered. The data were analysed using version 18.0 of the statistics program SPSS. A total of 53 desensitization protocols were administered to 21 patients. In 89 % of these cases, no new reactions occurred while the drug was being administered. New reactions of mild severity only occurred in 11 % of cases, and none of these reactions were severe enough for treatment to be stopped. All patients were able to complete the desensitization protocol. This study confirms that oxaliplatin desensitization protocols are safe and effective and allow patients to continue with the treatment that initially caused an HSR.

  5. Bracketing effects on risk tolerance

    Directory of Open Access Journals (Sweden)

    Ester Moher

    2010-08-01

    Full Text Available Research has shown that risk tolerance increases when multiple decisions and associated outcomes are presented together in a broader ``bracket'' rather than one at a time. The present studies disentangle the influence of problem bracketing (presenting multiple investment options together from that of outcome bracketing (presenting the aggregated outcomes of multiple decisions, factors which have been deliberately confounded in previous research. In the standard version of the bracketing task, in which participants decide how much of an initial endowment to invest into each in a series of repeated, identical gambles, we find a problem bracketing effect but not an outcome bracketing effect. However, this pattern of results does not generalize to the cases of non-identical gambles nor discrete choice, where we fail to find the standard bracketing effect.

  6. A Simplified Lingual Bracket Positioner

    Directory of Open Access Journals (Sweden)

    Sharath Kumar Shetty

    2014-01-01

    Full Text Available The indirect bonding system for lingual brackets may be broadly classified as; techniques using setup models and those using diagnostic models. The techniques using setup models are more accurate and many of them require the use of lingual bracket positioners for determining the correct position of brackets. We have devised a simpler yet reliable and effective bracket positioner ′Lingual Bracket Positioner′ in our department. Although many variants are available commercially, this design is easy to fabricate, cheap and ready to use.

  7. Antibiotic Desensitization Therapy in Secondary Syphilis and Listeria Infection: Case Reports and Review of Desensitization Therapy

    Science.gov (United States)

    Magpantay, Gil; Madar, Cristian S; Hsue, Gunther; Belnap, Conrad

    2011-01-01

    Two adult cases, one of secondary syphilis and one of Listeria monocytogenes bacteremia, in which antibiotic desensitization therapy was utilized to assist treatment of active infection in the face of severe penicillin allergy. Clinical considerations are discussed that led to the decision to employ a formal desensitization procedure. Antibiotic desensitization protocols can facilitate optimal and safe antibiotic therapy in the appropriate clinical setting. PMID:22187514

  8. Three-dimensional deformation of orthodontic brackets

    Science.gov (United States)

    Melenka, Garrett W; Nobes, David S; Major, Paul W

    2013-01-01

    Braces are used by orthodontists to correct the misalignment of teeth in the mouth. Archwire rotation is a particular procedure used to correct tooth inclination. Wire rotation can result in deformation to the orthodontic brackets, and an orthodontic torque simulator has been designed to examine this wire–bracket interaction. An optical technique has been employed to measure the deformation due to size and geometric constraints of the orthodontic brackets. Images of orthodontic brackets are collected using a stereo microscope and two charge-coupled device cameras, and deformation of orthodontic brackets is measured using a three-dimensional digital image correlation technique. The three-dimensional deformation of orthodontic brackets will be evaluated. The repeatability of the three-dimensional digital image correlation measurement method was evaluated by performing 30 archwire rotation tests using the same bracket and archwire. Finally, five Damon 3MX and five In-Ovation R self-ligating brackets will be compared using this technique to demonstrate the effect of archwire rotation on bracket design. PMID:23762201

  9. Three-dimensional deformation of orthodontic brackets.

    Science.gov (United States)

    Melenka, Garrett W; Nobes, David S; Major, Paul W; Carey, Jason P

    2013-01-01

    Braces are used by orthodontists to correct the misalignment of teeth in the mouth. Archwire rotation is a particular procedure used to correct tooth inclination. Wire rotation can result in deformation to the orthodontic brackets, and an orthodontic torque simulator has been designed to examine this wire-bracket interaction. An optical technique has been employed to measure the deformation due to size and geometric constraints of the orthodontic brackets. Images of orthodontic brackets are collected using a stereo microscope and two charge-coupled device cameras, and deformation of orthodontic brackets is measured using a three-dimensional digital image correlation technique. The three-dimensional deformation of orthodontic brackets will be evaluated. The repeatability of the three-dimensional digital image correlation measurement method was evaluated by performing 30 archwire rotation tests using the same bracket and archwire. Finally, five Damon 3MX and five In-Ovation R self-ligating brackets will be compared using this technique to demonstrate the effect of archwire rotation on bracket design.

  10. Comparison of Frictional Forces Generated by a New Ceramic Bracket with the Conventional Brackets using Unconventional and Conventional Ligation System and the Self-ligating Brackets: An In Vitro Study.

    Science.gov (United States)

    Pasha, Azam; Vishwakarma, Swati; Narayan, Anjali; Vinay, K; Shetty, Smitha V; Roy, Partha Pratim

    2015-09-01

    Fixed orthodontic mechanotherapy is associated with friction between the bracket - wire - ligature interfaces during the sliding mechanics. A sound knowledge of the various factors affecting the magnitude of friction is of paramount importance. The present study was done to analyze and compare the frictional forces generated by a new ceramic (Clarity Advanced) bracket with the conventional, (metal and ceramic) brackets using unconventional and conventional ligation system, and the self-ligating (metal and ceramic) brackets in the dry condition. The various bracket wire ligation combinations were tested in dry condition. The brackets used were of 0.022″ × 0.028″ nominal slot dimension of MBT prescription: Stainless steel (SS) self-ligating bracket (SLB) of (SmartClip), SS Conventional bracket (CB) (Victory series), Ceramic SLB (Clarity SL), Conventional Ceramic bracket with metal slot (Clarity Bracket), Clarity Advanced Ceramic Brackets (Clarity(™) ADVANCED, 3M Unitek). These brackets were used with two types of elastomeric ligatures: Conventional Elastomeric Ligatures (CEL) (Clear medium mini modules) and Unconventional Elastomeric Ligatures (UEL) (Clear medium slide ligatures, Leone orthodontic products). The aligning and the retraction wires were used, i.e., 0.014″ nickel titanium (NiTi) wires and 0.019″ × 0.025″ SS wires, respectively. A universal strength testing machine was used to measure the friction produced between the different bracket, archwires, and ligation combination. This was done with the use of a custom-made jig being in position. Mean, standard deviation, and range were computed for the frictional values obtained. Results were subjected to statistical analysis through ANOVA. The frictional resistance observed in the new Clarity Advanced bracket with a conventional elastomeric ligature was almost similar with the Clarity metal slot bracket with a conventional elastomeric ligature. When using the UEL, the Clarity Advanced bracket

  11. Evaluation of mechanical properties of esthetic brackets.

    Science.gov (United States)

    Matsui, Shigeyuki; Umezaki, Eisaku; Komazawa, Daigo; Otsuka, Yuichiro; Suda, Naoto

    2015-01-01

    Plastic brackets, as well as ceramic brackets, are used in various cases since they have excellent esthetics. However, their mechanical properties remain uncertain. The purpose of this study was to determine how deformation and stress distribution in esthetic brackets differ among materials under the same wire load. Using the digital image correlation method, we discovered the following: (1) the strain of the wings of plastic brackets is within 0.2% and that of ceramic and metal brackets is negligible, (2) polycarbonate brackets having a stainless steel slot show significantly smaller displacement than other plastic brackets, and (3) there is a significant difference between plastic brackets and ceramic and stainless steel brackets in terms of the displacement of the bracket wing.

  12. Comparative study on direct and indirect bracket bonding techniques regarding time length and bracket detachment

    Directory of Open Access Journals (Sweden)

    Jefferson Vinicius Bozelli

    2013-12-01

    Full Text Available OBJECTIVE: The aim of this study was to assess the time spent for direct (DBB - direct bracket bonding and indirect (IBB - indirect bracket bonding bracket bonding techniques. The time length of laboratorial (IBB and clinical steps (DBB and IBB as well as the prevalence of loose bracket after a 24-week follow-up were evaluated. METHODS: Seventeen patients (7 men and 10 women with a mean age of 21 years, requiring orthodontic treatment were selected for this study. A total of 304 brackets were used (151 DBB and 153 IBB. The same bracket type and bonding material were used in both groups. Data were submitted to statistical analysis by Wilcoxon non-parametric test at 5% level of significance. RESULTS: Considering the total time length, the IBB technique was more time-consuming than the DBB (p < 0.001. However, considering only the clinical phase, the IBB took less time than the DBB (p < 0.001. There was no significant difference (p = 0.910 for the time spent during laboratorial positioning of the brackets and clinical session for IBB in comparison to the clinical procedure for DBB. Additionally, no difference was found as for the prevalence of loose bracket between both groups. CONCLUSION: the IBB can be suggested as a valid clinical procedure since the clinical session was faster and the total time spent for laboratorial positioning of the brackets and clinical procedure was similar to that of DBB. In addition, both approaches resulted in similar frequency of loose bracket.

  13. Non-equal-time Poisson brackets

    OpenAIRE

    Nikolic, H.

    1998-01-01

    The standard definition of the Poisson brackets is generalized to the non-equal-time Poisson brackets. Their relationship to the equal-time Poisson brackets, as well as to the equal- and non-equal-time commutators, is discussed.

  14. Bracket for photovoltaic modules

    Science.gov (United States)

    Ciasulli, John; Jones, Jason

    2014-06-24

    Brackets for photovoltaic ("PV") modules are described. In one embodiment, a saddle bracket has a mounting surface to support one or more PV modules over a tube, a gusset coupled to the mounting surface, and a mounting feature coupled to the gusset to couple to the tube. The gusset can have a first leg and a second leg extending at an angle relative to the mounting surface. Saddle brackets can be coupled to a torque tube at predetermined locations. PV modules can be coupled to the saddle brackets. The mounting feature can be coupled to the first gusset and configured to stand the one or more PV modules off the tube.

  15. Delayed bracket placement in orthodontic treatment

    Directory of Open Access Journals (Sweden)

    Chandra Wigati

    2008-12-01

    Full Text Available Background: Beside bracket position, the timing of bracket placement is one of the most essential in orthodontic treatment with fixed appliances. Even it seems simple the timing of bracket placement can be crucial and significantly influence the result of orthodontic treatment. However it is often found brackets are placed without complete understanding of its purpose and effects, which could be useless and even detrimental for the case. Purpose: The aim of this case report is to show that the timing of bracket placement could be different depending on the cases. Case: Five different cases are presented here with different timing of bracket placement. Case management: On these cases, brackets were placed on the upper arch first, on the lower arch first, or even only on some teeth first. Good and efficient orthodontic treatment results were achieved. Conclusion: For every orthodontic case, from the very beginning of treatment, bracket should be placed with the end result in mind. If brackets are correctly placed at a correct time, better treatment result could be achieved without unnecessary round tripping tooth movement.

  16. Orthodontic Bracket Manufacturing Tolerances and Dimensional Differences between Select Self-Ligating Brackets

    Science.gov (United States)

    Major, Thomas W.; Carey, Jason P.; Nobes, David S.; Major, Paul W.

    2010-01-01

    In all manufacturing processes there are tolerances; however, orthodontic bracket manufacturers seldom state the slot dimensional tolerances. This experiment develops a novel method of analyzing slot profile dimensions using photographs of the slot. Five points are selected along each wall, and lines are fitted to define a trapezoidal slot shape. This investigation measures slot height at the slot's top and bottom, angles between walls, slot taper, and the linearity of each wall. Slot dimensions for 30 upper right central incisor self-ligating stainless steel brackets from three manufacturers were evaluated. Speed brackets have a slot height 2% smaller than the nominal 0.559 mm size and have a slightly convergent taper. In-Ovation brackets have a divergent taper at an average angle of 1.47 degrees. In-Ovation is closest to the nominal value of slot height at the slot base and has the smallest manufacturing tolerances. Damon Q brackets are the most rectangular in shape, with nearly 90-degree corners between the slot bottom and walls. Damon slot height is on average 3% oversized. PMID:20981299

  17. Aspirin Allergy Desensitization in Cerebrovascular Disease

    Science.gov (United States)

    Zuckerman, Scott L; Seder, David B; Tsujiura, Crystiana; Cushing, Deborah; Gallup, Holly; Mocco, J; Hanel, Richard A; Ecker, Robert D

    2014-01-01

    Summary Aspirin (ASA) is the mainstay of treatment in cerebrovascular and systemic vascular disease. ASA hypersensitivity can pose a challenge to achieving optimum medical management prior to and after neurointerventional treatment. Desensitization to ASA is well described in the allergy and cardiovascular literature, but there are no similar discussions specific to neurointervention. The purpose of our study was to describe our experience with ASA hypersensitivity management and review the relevant literature. Two cases of patients with symptomatic cerebrovascular disease requiring neurointervention who were successfully desensitized to their ASA hypersensitivity prior to treatment are described. The subsequent literature is reviewed. Several ASA desensitization protocols exist and have been proven to successfully treat ASA hypersensitivity and allow for ASA therapy to be safely initiated. We describe several previously published protocols. ASA desensitization is a safe and simple way to manage ASA hypersensitivity. We provide comprehensive management guidelines for the neurointerventionalist engaging in ASA desensitization. PMID:24556294

  18. In Vitro Desensitization of Human Skin Mast Cells

    Science.gov (United States)

    Zhao, Wei; Gomez, Gregorio; Macey, Matthew; Kepley, Christopher L.

    2013-01-01

    Desensitization is a clinical procedure whereby incremental doses of a drug are administered over several hours to a sensitive patient until a therapeutic dose and clinical tolerance are achieved. Clinical tolerance may occur in part by attenuating the mast cell response. In the present study, primary human skin mast cells were used to establish and characterize an in vitro model of desensitization. Mast cells in culture were armed with allergen-specific (4-hydroxy-3-nitro-phenylacety and Der p2) and non-specific IgE antibodies, and then desensitized by incremental exposures to 4-hydroxy-3-nitrophenylacety-BSA. This desensitization procedure abrogated the subsequent degranulation response to the desensitizing allergen, to an unrelated allergen, and to IgG anti-FcεRI, but not to C5a, substance P, compound 48/80, and calcium ionophore. Desensitized cells regained their FcεRI-dependent degranulation capability by 24–48 h after free allergen had been removed. Therefore, sensitized human skin mast cells are reversibly desensitized in vitro by exposure to incremental doses of that allergen, which also cross-desensitizes them to an unrelated allergen. PMID:22009002

  19. Desensitization to Oxcarbazepine: Long-Term Efficacy and Tolerability

    Science.gov (United States)

    Lee, Jiwon; Park, Eu Gene; Lee, Munhyang

    2017-01-01

    Background and Purpose Antiepileptic drug (AED)-associated cutaneous adverse drug reactions can lead to the discontinuation of medications. The aim of this study was to determine the long-term efficacy and safety of performing desensitization to oxcarbazepine. Methods This study involved 20 patients who exhibited cutaneous adverse drug reactions associated with oxcarbazepine use between July 2009 and March 2016 at Samsung Medical Center. All of the participants had to discontinue oxcarbazepine despite presenting initially positive responses. Human leukocyte antigen genotyping was performed to detect the genetic predisposition to Stevens-Johnson syndrome. The desensitization to oxcarbazepine was performed with a starting dosage of 0.1 mg/day. Efficacy was evaluated by comparing the frequency of seizures before and at 1 and 3 years after desensitization. Adverse events occurring during desensitization and the retention rate after desensitization were also investigated. Results Nineteen patients (95%) safely completed the desensitization protocol. One withdrew owing to emotional problems that appeared to be associated with oxcarbazepine. The follow-up period was 4.6±1.2 years (mean±SD), and oxcarbazepine was maintained for more than 3 years after desensitization in 15 patients (83.3%). The response rates were 84.2% and 77.8% at 1 and 3 years after desensitization, respectively. Eight patients remained seizure-free for 3 years, and two discontinued all AEDs. Transient adverse reactions such as mild rash and itching were reported by five patients during desensitization. Conclusions This study has demonstrated the long-term efficacy and safety of desensitization to oxcarbazepine in patients exhibiting cutaneous adverse drug reactions. This favorable outcome should encourage the implementation of desensitization in patients presenting with hypersensitivity to oxcarbazepine as an alternative strategy in clinical practice. PMID:27730770

  20. Adhesive performance of precoated brackets after expiration.

    Science.gov (United States)

    Cloud, Cayce C; Trojan, Terry M; Suliman, Sam N; Tantbirojn, Daranee; Versluis, Antheunis

    2016-03-01

    To evaluate adhesive performance in terms of debonding forces of precoated metal and ceramic brackets 4 years after expiration. Buccal and lingual surfaces of embedded extracted maxillary premolars were etched with 34% Tooth Conditioner Gel (Dentsply Caulk, Milford, Del), rinsed, and dried. Transbond MIP (3M Unitek, Monrovia, Calif) was applied prior to placing adhesive precoated brackets (APC II Victory stainless steel and APC Plus Clarity ceramic brackets, 3M Unitek). The preexpiration brackets had 29-35 months before, and the postexpiration brackets were 45-52 months past, their expiration dates. Sample size was 17-21 per group. Debonding forces were determined by subjecting the bonded brackets to a shear force in a universal testing machine. Debonding forces were compared using two-way ANOVA. Debonded surfaces were examined under a stereomicroscope to determine failure modes, which were compared using the chi-square test. No statistically significant difference was found in debonding forces (P  =  .8581) or failure modes (P  =  .4538) between expired and unexpired brackets. Metal brackets required statistically significantly higher debonding forces than did ceramic brackets (P  =  .0001). For both expired and unexpired brackets, failure modes were mostly cohesive in the adhesive layer for ceramic brackets, and mixed between adhesive and cohesive failure in the adhesive layer for metal brackets. Adhesive precoated brackets did not have any reduction in enamel-adhesion properties up to 4 years after their expiration date. Extended shelf life testing for precoated dental brackets may be worth considering.

  1. Desensitization in patients with beta-lactam drug allergy.

    Science.gov (United States)

    Yusin, J S; Klaustermeyer, W; Simmons, C W; Baum, M

    2013-01-01

    Patients with a history of beta-lactam antibiotic allergy are often admitted to the hospital with severe or life-threatening infections requiring beta-lactam antibiotics. Strict avoidance of beta lactams to such patients may prevent them from getting adequate coverage and can lead to an increase in the use of alternative antibiotics, which can predispose to antibiotic resistance. Past studies revealed a lower incidence of pen allergy then patients' histories suggest. Fortunately today, there are three options for patients presenting with a history of beta-lactam allergy. Penicillin skin testing, beta-lactam challenge or beta-lactam desensitization. Recently Pre Pen has been FDA re-approved and when combined with Pen G is a valid way to determine if patients are able to tolerate beta-lactam antibiotic. When these agents are not available one must decide about desensitization or challenge. When a patient has a positive penicillin skin test, desensitization or beta-lactam avoidance are the only options. This paper reviews the safety of beta-lactam desensitization. To perform a chart review on patients desensitised with beta lactam to determine if desensitizations can be performed safely without minimal complications. A retrospective chart review was performed on allergy and immunology inpatient consultations for beta-lactam desensitization between September 2003 and August 2006 at the Cedars-Sinai Medical Centre in Los Angeles. Patient data and outcomes of desensitization were analysed. A total of 13 intravenous desensitizations were performed on 12 patients. The patients consisted of eight females and four males with an average age of 65 years. Age range was 36-92 years old. All 13 intravenous desensitizations were completed without complications. No patient required a slower rate of desensitization or discontinuance of the desensitization. Patients were able to tolerate the initial therapeutic dose of their beta-lactam antibiotic and were then able to complete full

  2. Exterior differentials in superspace and Poisson brackets

    International Nuclear Information System (INIS)

    Soroka, Dmitrij V.; Soroka, Vyacheslav A.

    2003-01-01

    It is shown that two definitions for an exterior differential in superspace, giving the same exterior calculus, yet lead to different results when applied to the Poisson bracket. A prescription for the transition with the help of these exterior differentials from the given Poisson bracket of definite Grassmann parity to another bracket is introduced. It is also indicated that the resulting bracket leads to generalization of the Schouten-Nijenhuis bracket for the cases of superspace and brackets of diverse Grassmann parities. It is shown that in the case of the Grassmann-odd exterior differential the resulting bracket is the bracket given on exterior forms. The above-mentioned transition with the use of the odd exterior differential applied to the linear even/odd Poisson brackets, that correspond to semi-simple Lie groups, results, respectively, in also linear odd/even brackets which are naturally connected with the Lie superalgebra. The latter contains the BRST and anti-BRST charges and can be used for calculation of the BRST operator cogomology. (author)

  3. Aspirin Desensitization

    Science.gov (United States)

    ... Nerve Decompression Dacryocystorhinostomy (DCR) Disclosure Statement Printer Friendly Aspirin Desensitization Kevin C. Welch, MD Zara Patel, MD Introduction The term "aspirin-sensitive asthma" (also known as "aspirin triad" or " ...

  4. Using humor in systematic desensitization to reduce fear.

    Science.gov (United States)

    Ventis, W L; Higbee, G; Murdock, S A

    2001-04-01

    Effectiveness of systematic desensitization for fear reduction, using humorous hierarchy scenes without relaxation, was tested. Participants were 40 students highly fearful of spiders. Using a 24-item behavioral approach test with an American tarantula, participants were matched on fear level and randomly assigned to 1 of 3 treatment groups: (a) systematic desensitization, (b) humor desensitization, and (c) untreated controls. Each participant was seen for 6 sessions, including pretest and posttest. Analyses of covariance of posttest scores revealed that the 2 treatment groups showed greater reduction in fear than the controls on 3 measures but did not differ from each other. Therefore, humor in systematic desensitization reduced fear as effectively as more traditional desensitization. This finding may have therapeutic applications; however, it may also be applicable in advertising to desensitize fear of a dangerous product, such as cigarettes.

  5. Relaxation and Distraction in Experimental Desensitization.

    Science.gov (United States)

    Weir, R. O.; Marshall, W. L.

    1980-01-01

    Compared experimental desensitization with a procedure that replaced relaxation with a distraction task and with an approach that combined both relaxation and distraction. Desensitization generally was more effective than the other two procedures. (Author)

  6. Material testing of reconditioned orthodontic brackets.

    Science.gov (United States)

    Reimann, S; Rewari, A; Keilig, L; Widu, F; Jäger, A; Bourauel, C

    2012-12-01

    While all manufacturers of orthodontic brackets label these products for single use, there are commercial providers offering bracket reconditioning (or "recycling"). We conducted this study to investigate the effects of different recycling techniques on material-related parameters in orthodontic brackets, aiming to derive indications for clinical use and conclusions about the biocompatibility, longevity, and application of recycled brackets. New metal brackets (equilibrium(®); Dentaurum, Ispringen, Germany) were compared to brackets recycled by different techniques, including direct flaming with a Bunsen burner, chemical reconditioning in an acid bath, a commercial unit (Big Jane; Esmadent, IL, USA), and outsourcing to a company (Ortho Clean, Dellstedt, Germany). Material-related examinations included the following: (1) corrosion behavior by static immersion testing and use of a mass spectrometer to determine nickel-ion concentrations in the corrosive medium, (2) surface features in scanning electron micrographs before and after corrosion testing, (3) Vickers hardness using a hardness testing machine, (4) shear bond strength as defined in DIN 13990-1, (5) dimensional stability of the bracket slots by light microscopy, and (6) frictional loss as assessed by an orthodontic measurement and simulation system (OMSS). Each examination was performed on ten brackets. Student's t-test was used for statistical analysis. Compared to the new brackets, those recycled in an acid bath or by a commercial provider revealed significant dimensional changes (pbrackets varied according to the recycling techniques employed. The group of brackets recycled by one company revealed hardness values that differed from those of all the other groups. No significant differences were observed in nickel-ion release, frictional loss, and shear bond strength. Recycling was found to significantly reduce the corrosion resistance and dimensional stability of orthodontic brackets. As the savings

  7. Desensitization of parathyroid hormone receptors on cultured bone cells

    International Nuclear Information System (INIS)

    Pun, K.K.; Ho, P.W.; Nissenson, R.A.; Arnaud, C.D.

    1990-01-01

    Administration of excessive amounts of parathyroid hormone (PTH) in the treatment of osteoporosis can reverse the beneficial effects of a low-dose, intermittent regime. To investigate the direct actions and the possible cellular mechanisms of PTH in inducing desensitization of PTH receptors, we studied the effects of desensitization on rat osteoblastic UMR-106 cells. When the osteoblasts were preincubated with bPTH-(1-34), complete refractoriness to a subsequent challenge with the hormone developed within 1 h and at hormone concentrations as low as 5 nM. When osteoblasts thus desensitized were incubated in hormone-free medium, recovery of the cAMP responses began within 2 h and reached maximum after 16 h. Cycloheximide did not affect the process of desensitization. [Nle8,Nle18,Tyr34]bPTH-(3-34)amide significantly impaired the desensitization process by PTH-(1-34) but did not have stimulatory effect on cAMP responses. No significant heterologous desensitization was obvious after preincubation with isoprenaline (50 microM), prostaglandin E1 (50 microM), or prostaglandin E2 (50 microM) for 2 h. Binding experiments with [125I]PLP-(1-36)amide after desensitization revealed that there was an approximate twofold decrease in receptor affinities as analyzed by Scatchard analysis, showing that the decrease in affinity was prominent in the process of desensitization. When the cells were treated with monensin during desensitization, PTH challenge after desensitization produced significantly lower cyclic AMP responses. Recovery after desensitization occurred over a period of 16 h. Inclusion of monensin, but not cycloheximide, impaired the recovery. The results show that homologous desensitization of rat osteoblasts to PTH is brought about by the occupancy of receptors by PTH-(1-34) but not by cAMP generation itself

  8. Carboplatin hypersensitivity: evaluation and successful desensitization protocol.

    Science.gov (United States)

    Bruchim, Ilan; Goldberg, Arnon; Fishman, Ami; Confino-Cohen, Ronit

    2014-01-01

    Carboplatin-induced immediate hypersensitivity reactions are relatively common among patients with gynecological malignancies. Once this occurs, the patient might be at risk for future carboplatin-induced reactions. This study evaluated the efficacy of allergic consultation, carboplatin skin testing and desensitization as a single intervention strategy in this population. Patients with a well-documented immediate reaction to carboplatin were offered allergy consultation, carboplatin skin testing and a desensitization plan in a single visit between scheduled chemotherapy sessions. Fifty-five patients with an immediate reaction were evaluated. After allergist assessment, 44 (89%) of 49 patients skin tested had a positive result. A total of 207 carboplatin desensitization cycles were administered to 49 women. Among them, 10 patients had a mild immediate hypersensitivity reaction during desensitization. Five patients subsequently tolerated carboplatin administered in the prolonged desensitization protocol. In the data presented, we propose a strategy that is both cost effective and very convenient for the patient. The diagnostic procedure, including allergist consultation and skin test, can be completed in less than 2 h. In most cases where carboplatin is indispensable, desensitization can be administered without overnight hospitalization.

  9. Desensitization and recovery of phototropic responsiveness in Arabidopsis thaliana

    Science.gov (United States)

    Janoudi, A. K.; Poff, K. L.

    1993-01-01

    Phototropism is induced by blue light, which also induces desensitization, a partial or total loss of phototropic responsiveness. The fluence and fluence-rate dependence of desensitization and recovery from desensitization have been measured for etiolated and red light (669-nm) preirradiated Arabidopsis thaliana seedlings. The extent of desensitization increased as the fluence of the desensitizing 450-nm light was increased from 0.3 to 60 micromoles m-2 s-1. At equal fluences, blue light caused more desensitization when given at a fluence rate of 1.0 micromole m-2 s-1 than at 0.3 micromole m-2 s-1. In addition, seedlings irradiated with blue light at the higher fluence rate required a longer recovery time than seedlings irradiated at the lower fluence rate. A red light preirradiation, probably mediated via phytochrome, decreased the time required for recovery from desensitization. The minimum time for detectable recovery was about 65 s, and the maximum time observed was about 10 min. It is proposed that the descending arm of the fluence-response relationship for first positive phototropism is a consequence of desensitization, and that the time threshold for second positive phototropism establishes a period during which recovery from desensitization occurs.

  10. Three-dimensional deformation of orthodontic brackets

    OpenAIRE

    Melenka, Garrett W; Nobes, David S; Major, Paul W; Carey, Jason P

    2013-01-01

    Braces are used by orthodontists to correct the misalignment of teeth in the mouth. Archwire rotation is a particular procedure used to correct tooth inclination. Wire rotation can result in deformation to the orthodontic brackets, and an orthodontic torque simulator has been designed to examine this wire?bracket interaction. An optical technique has been employed to measure the deformation due to size and geometric constraints of the orthodontic brackets. Images of orthodontic brackets are c...

  11. Endogenous Opiate System and Systematic Desensitization.

    Science.gov (United States)

    Egan, Kelly J.; And Others

    1988-01-01

    Administered intravenous infusions to phobic patients prior to systematic desensitization. Saline-infused subjects significantly demonstrated the predicted symptom decrease in response to systematic desensitization, whereas naloxone-infused subjects showed no change. Subject reports and psychophysiological measures of arousal indicated no…

  12. Clinical Survival of Rebonded Brackets with Different ARI Scores

    Directory of Open Access Journals (Sweden)

    Mohammad Hossein Ahangar Atashi

    2016-01-01

    Full Text Available Introduction: Bracket debonding is one of the most common events in orthodontics. The aim of the present study was to quantitatively compare clinical survival of rebonded brackets with different ARI scores with new brackets rebonding. Materials and Methods: The subjects in the present study consisted of 74 patients with 76 debonded brackets on maxillary first and second premolars. After refreshing the bracket base of the debonded brackets, they were assigned in two groups: group A with 27 brackets of ARI≥4 and group B with 28 brackets of ARI≤2. In 21 cases, new brackets were used (group C. The frequency of the debonding in each rebonded group during treatment was calculated in intervals of 6,12,18 mounths after onset of bracket rebonding . Chi-squared test was used to compare the frequency of debonded brackets. Results: The frequency of debonded brackets was significantly higher in group B (ARI≤2 than those of groups A (ARI≥4 and C (new brackets. The number of debonded brackets were not significantly different between groups A (ARI≥4 and C (new brackets. Conclusion: Rebonding strength of debonded brackets in those that the failure is presented between adhesive and enamel (ARI≥4 could be clinically acceptable with no need to use new brackets.    Key words: dental bonding; orthodontic brackets; prevalence

  13. Evaluation of mechanical properties of esthetic brackets

    OpenAIRE

    Matsui, Shigeyuki; Umezaki, Eisaku; Komazawa, Daigo; Otsuka, Yuichiro; Suda, Naoto

    2015-01-01

    Plastic brackets, as well as ceramic brackets, are used in various cases since they have excellent esthetics. However, their mechanical properties remain uncertain. The purpose of this study was to determine how deformation and stress distribution in esthetic brackets differ among materials under the same wire load. Using the digital image correlation method, we discovered the following: (1) the strain of the wings of plastic brackets is within 0.2% and that of ceramic and metal brackets is n...

  14. Torque expression in self-ligating orthodontic brackets and conventionally ligated brackets: A systematic review

    OpenAIRE

    Al-Thomali, Yousef; Mohamed, Roshan-Noor; Basha, Sakeenabi

    2017-01-01

    Background To evaluate the torque expression of self ligating (SL) orthodontic brackets and conventionally ligated brackets and the torque expression in active and passive SL brackets. Material and Methods Our systematic search included MEDLINE, EMBASE, CINAHL, PsychINFO, Scopus, and key journals and review articles; the date of the last search was April 4th 2016. We graded the methodological quality of the studies by means of the Quality Assessment Tool for Quantitative Studies, developed fo...

  15. A new 2 D bracket positioning gauge

    Directory of Open Access Journals (Sweden)

    Bhuwan Saklecha

    2017-01-01

    Full Text Available Bracket positioning is the basic premise of pre-adjusted system, which allows the teeth to be placed with a straight wire into an occlusal contact with an excellent mesiodistal inclination (tip and excellent faciolingual inclination (torque. Improper bracket placement may lead to poorly placed teeth and necessitate bracket repositioning and archwire adjustments. This can lead to an increased treatment time or poor occlusion. Therefore, a bracket positioning gauge has been designed using both the planes and evaluated for its accuracy in bonding of brackets. It was found that the gauge not only helped in the placement of brackets accurately, but also reduced chairside time.

  16. Aspirin challenge and desensitization: how, when and why.

    Science.gov (United States)

    Cortellini, Gabriele; Caruso, Cristiano; Romano, Antonino

    2017-08-01

    To investigate the current approach to aspirin challenge (drug provocation) and/or desensitization in patients with histories of hypersensitivity reactions to it, particularly in those with cardiovascular diseases. The literature indicates that patients with coronary artery disease (CAD), including those with an acute coronary syndrome, may safely undergo low-dose aspirin challenge and/or desensitization. Recently, flowcharts regarding challenge/desensitization procedures with aspirin in patients with CAD and histories of aspirin hypersensitivity reactions have become available. Aspirin desensitization and continuous aspirin therapy constitute an effective option in patients with nonsteroidal anti-inflammatory drug-exacerbated respiratory diseases (NERD) who have suboptimally controlled asthma or rhinosinusitis, or require multiple revision polypectomies. The use of aspirin has proven to reduce morbidity and mortality associated with CAD. There is a general consensus on aspirin's effectiveness in secondary prevention of CAD. Therefore, aspirin desensitization is necessary in patients with CAD and histories of hypersensitivity reactions to it. The effectiveness of aspirin desensitization and continuous therapy in patients with NERD has been shown in numerous studies. However, shared selection criteria of candidates for aspirin challenge/desensitization procedures, and simple and homogeneous protocols are necessary. Moreover, preventive safety measures are still needed in order to reduce the potential risks of these procedures.

  17. Medication Desensitization: Characterization of Outcomes and Risk Factors for Reactions.

    Science.gov (United States)

    Murray, Taryn S; Rice, Todd W; Wheeler, Arthur P; Phillips, Elizabeth J; Dworski, Ryszard T; Stollings, Joanna L

    2016-03-01

    Although its mechanisms are poorly understood, desensitization has been used to induce a temporary state of immune unresponsiveness in patients who have IgE-, non-IgE-, or pharmacologically mediated reactions when a drug has no alternatives. The purpose of this study was to characterize the outcomes and identify risk factors for reactions during drug desensitization. A retrospective review of electronic medical records of adult patients undergoing drug desensitization from January 1, 2011, to December 31, 2013, was conducted in 2 intensive care units at a tertiary medical center. We used multivariate analysis to determine if specified risk factors were associated with reacting during the desensitization. Reactions were classified according to the pretest probability prior to desensitization, and then, reactions during desensitization were classified based on the occurrence of cutaneous reactions as follows: successful with no reaction, mild reaction, moderate reaction, or failed. Failure could result from any systemic allergic or cutaneous reaction resulting in procedure termination. The desensitizations were also assessed to determine if the patient required de-escalation secondary to a reaction. A total of 88 desensitizations were performed in 69 patients. Desensitization was completed with no cutaneous reaction in 85% of patients. No baseline characteristic, medication class (P = 0.46), or indication for desensitization (P = 0.59) was associated with having a reaction. Reported histories of urticaria (P desensitization. However, neither history of urticaria nor labored breathing was independently associated with having a reaction in multivariate analysis (OR = 0.979, 95% CI = 0.325-2.952, P = 0.970, and OR = 1.626, 95% CI = 0.536-4.931, P = 0.739, respectively). Drug desensitization is safe for patients who have no alternative for therapy. Reported allergy histories of urticaria and labored breathing are both associated with having a reaction during the

  18. Assessment of bracket surface morphology and dimensional change

    Directory of Open Access Journals (Sweden)

    Pillai Devu Radhakrishnan

    2017-01-01

    Full Text Available Objective: The objective of this study was to compare the surface morphology and dimensional stability of the bracket slot at the onset of treatment and after 12 months of intraoral exposure. The study also compared the amount of calcium at the bracket base which indicates enamel loss among the three orthodontic brackets following debonding after 12 months of intraoral exposure. Materials and Methods: The sample consisted of 60 (0.022” MBT canine brackets. They were divided into three groups: self-ligating, ceramic bracket with metal slot, and stainless steel (SS brackets. The slot dimensions, micromorphologic characteristics of as-received and retrieved brackets were measured with a stereomicroscope and scanning electron microscope (SEM, respectively. The amount of calcium at the bracket base which indicates enamel damage was quantified using energy-dispersive X-ray spectrometry (EDX. Results: The results showed statistically significant alterations (P < 0.05 in the right vertical dimension, internal tie wing width (cervical, right and left depth of the slot (Kruskal–Wallis test. Multiple comparison using Mann–Whitney test showed that ceramic brackets underwent (P < 0.05 minimal alterations in the right vertical dimension, internal tie wing width (cervical, right and left depth of the slot (0.01 mm, −0.003 mm, 0.006 mm, −0.002 mm, respectively when compared with the changes seen in SS and self-ligating brackets. SEM analysis revealed an increase in the surface roughness of ceramic with metal slot brackets and self-ligating bracket showed the least irregularity. The presence of calcium was noted on all evaluated brackets under EDX, but ceramic with metal slot brackets showed a significantly greater amount of enamel loss (P = 0.001. Conclusion: Ceramic brackets were found to be dimensionally stable when compared to SS and self-ligating. Self-ligating bracket showed minimal surface irregularity. Ceramic with metal slot brackets showed a

  19. Frictional Resistance of Three Types of Ceramic Brackets

    Directory of Open Access Journals (Sweden)

    Claire L Williams

    2014-01-01

    Full Text Available Objectives: To investigate the static frictional resistance at the bracket/archwire interface in two recently introduced bracket systems and compare them to conventional ceramic and conventional metal bracket systems. Three variables were considered including the bracket system, archwire type and archwire angulation. Material and Methods: Four bracket systems were tested in vitro: Self ligating ceramic, ceramic with metal slot and module, conventional ceramic with module and conventional metal with module. A specially constructed jig and an Instron testing machine were used to measure the static frictional resistance for 0.014 inches round and 0.018 x 0.025 inches rectangular stainless steel wires at 0° and 7° angulations. Main outcome measures: static frictional force at the bracket/archwire interface; recorded and measured in units of force (Newtons. Results: Self ligating ceramic and metal slot ceramic bracket systems generated significantly less static frictional resistance than conventional ceramic bracket systems with the wire at both angulations (P < 0.05. Changing the wire from 0.014 round to 0.018 x 0.025 rectangular wire significantly increased frictional forces for metal slot ceramic and conventional metal bracket systems (P < 0.01. Increasing wire angulation significantly increased frictional resistance at the bracket/archwire interface for all four types of bracket systems tested (P < 0.001. Conclusions: Compared to conventional ceramic, self ligating ceramic and metal slot ceramic bracket systems should give improved clinical performance, matching that of conventional metal brackets.

  20. Playing violent video games and desensitization to violence.

    Science.gov (United States)

    Brockmyer, Jeanne Funk

    2015-01-01

    This article examines current research linking exposure to violent video games and desensitization to violence. Data from questionnaire, behavioral, and psychophysiologic research are reviewed to determine if exposure to violent video games is a risk factor for desensitization to violence. Real-world implications of desensitization are discussed. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Quadratic Poisson brackets compatible with an algebra structure

    OpenAIRE

    Balinsky, A. A.; Burman, Yu.

    1994-01-01

    Quadratic Poisson brackets on a vector space equipped with a bilinear multiplication are studied. A notion of a bracket compatible with the multiplication is introduced and an effective criterion of such compatibility is given. Among compatible brackets, a subclass of coboundary brackets is described, and such brackets are enumerated in a number of examples.

  2. Desensitization and recovery of phototropic responsiveness in Arabidopsis thaliana

    International Nuclear Information System (INIS)

    Janoudi, A.K.; Poff, K.L.

    1993-01-01

    Phototropism is induced by blue light, which also induces desensitization, a partial or total loss of phototropic responsiveness. The fluence and fluence-rate dependence of densensitization and recovery from desensitization have been measured for etiolated and red light (669-nm) preirradiated Arabidopsis thaliana seedlings. The extent of desensitization increased as the fluence of the desensitizing 450-nm light was increased from 0.3 to 60 μmol m -2 s -1 . At equal fluences, blue light caused more desensitization when given at a fluence rate of 1.0 μmol m -2 s -1 than at 0.3 μmol m -2 s -1 . In addition, seedlings irradiated with blue light at the higher fluence rate required a longer recovery time than seedlings irradiated at the lower fluence rate. A red light preirradiation, probably mediated via phytochrome, decreased the time required for recovery from desensitization. The minimum time for detectable recovery was about 65 s, and the maximum time observed was about 10 min. It is proposed that the descending arm of the fluence-response relationship for first positive phototropism is a consequence of desensitization, and that the time threshold for second positive phototropism establishes a period during which recovery from desensitization occurs. 11 refs., 6 figs

  3. A scanning electron microscopic investigation of ceramic orthodontic brackets

    International Nuclear Information System (INIS)

    McDonald, F.; Toms, A.P.

    1990-01-01

    Ceramic brackets were introduced to overcome the esthetic disadvantages of stainless steel brackets. The clinical impression of these brackets is very favorable. However, the sliding mechanics used in the Straightwire (A Company, San Diego, CA, USA) system appear to produce slower tooth movements with ceramic compared to stainless steel brackets. To determine whether this was due to any obvious mechanical problem in the bracket slot, Transcend (Unitek Corporation/3M, Monrovia, CA, USA) ceramic brackets were examined by a scanning electron microscope and compared to stainless steel brackets.Consistently, large surface defects were found in the ceramic bracket slots that were not present in the metal bracket slots. These irregularities could obviously hinder the sliding mechanics of the bracket slot-archwire system and create a greater demand on anchorage. Conversely, the fitting surface of the Transcend ceramic bracket showed extremely smooth surface characteristics, and it would seem advisable for the manufacturers to incorporate this surface within the bracket slot. (author)

  4. Guided Mastery and Performance Desensitization Treatments.

    Science.gov (United States)

    Williams, S. Lloyd; And Others

    1985-01-01

    Compared desensitization and self-efficacy models of phobia treatment in height phobics. Self-efficacy treatment proved to be significantly more effective than desensitization treatment in restoring subjects' behavioral functioning, in raising their perceptions of self-efficacy, and in reducing their anticipated anxiety and thoughts of danger.…

  5. Microbial profile on metallic and ceramic bracket materials.

    Science.gov (United States)

    Anhoury, Patrick; Nathanson, Dan; Hughes, Christopher V; Socransky, Sigmund; Feres, Magda; Chou, Laisheng Lee

    2002-08-01

    The placement of orthodontic appliances creates a favorable environment for the accumulation of a microbiota and food residues, which, in time, may cause caries or exacerbate any pre-existing periodontal disease. The purpose of the present study was to compare the total bacterial counts present on metallic and ceramic orthodontic brackets in order to clarify which bracket type has a higher plaque retaining capacity and to determine the levels of Streptococcus mutans and Lactobacillus spp on both types of brackets. Thirty-two metallic brackets and 24 ceramic brackets were collected from orthodontic patients at the day of debonding. Two brackets were collected from each patient; one from a maxillary central incisor and another from a maxillary second premolar. Sixteen patients who used metallic brackets and 12 patients who used ceramic brackets were sampled. Bacterial populations were studied using "checkerboard" DNA-DNA hybridization, which uses DNA probes to identify species in complex microbial samples. The significance of differences between groups was determined using the Mann-Whitney U-test. Results showed no significant differences between metallic and ceramic brackets with respect to the caries-inducing S mutans and L acidophilus spp counts. Mean counts of 8 of 35 additional species differed significantly between metallic and ceramic brackets with no obvious pattern favoring one bracket type over the other. This study showed higher mean counts of Treponema denticola, Actinobacillus actinomycetemcomitans, Fusobacterium nucleatum ss vincentii, Streptococcus anginosus, and Eubacterium nodatum on metallic brackets while higher counts of Eikenella corrodens, Campylobacter showae, and Selenomonas noxia were found on ceramic brackets.

  6. Group Vicarious Desensitization of Test Anxiety.

    Science.gov (United States)

    Altmaier, Elizabeth Mitchell; Woodward, Margaret

    1981-01-01

    Studied test-anxious college students (N=43) who received either vicarious desensitization, study skills training, or both treatments; there was also a no-treatment control condition. Self-report measures indicated that vicarious desensitization resulted in lower test and trait anxiety than study skills training alone or no treatment. (Author)

  7. Poisson brackets of orthogonal polynomials

    OpenAIRE

    Cantero, María José; Simon, Barry

    2009-01-01

    For the standard symplectic forms on Jacobi and CMV matrices, we compute Poisson brackets of OPRL and OPUC, and relate these to other basic Poisson brackets and to Jacobians of basic changes of variable.

  8. Relaxation as a Factor in Semantic Desensitization

    Science.gov (United States)

    Bechtel, James E.; McNamara, J. Regis

    1975-01-01

    Relaxation and semantic desensitization were used to alleviate the fear of phobic females. Results showed that semantic desensitization, alone or in combination with relaxation, failed to modify the evaluative meanings evoked by the feared object. (SE)

  9. Desensitization protocols and their outcome.

    Science.gov (United States)

    Marfo, Kwaku; Lu, Amy; Ling, Min; Akalin, Enver

    2011-04-01

    In the last decade, transplantation across previously incompatible barriers has increasingly become popular because of organ donor shortage, availability of better methods of detecting and characterizing anti-HLA antibodies, ease of diagnosis, better understanding of antibody-mediated rejection, and the availability of effective regimens. This review summarizes all manuscripts published since the first publication in 2000 on desensitized patients and discusses clinical outcomes including acute and chronic antibody-mediated rejection rate, the new agents available, kidney paired exchange programs, and the future directions in sensitized patients. There were 21 studies published between 2000 and 2010, involving 725 patients with donor-specific anti-HLA antibodies (DSAs) who underwent kidney transplantation with different desensitization protocols. All studies were single center and retrospective. The patient and graft survival were 95% and 86%, respectively, at a 2-year median follow-up. Despite acceptable short-term patient and graft survivals, acute rejection rate was 36% and acute antibody-mediated rejection rate was 28%, which is significantly higher than in nonsensitized patients. Recent studies with longer follow-up of those patients raised concerns about long-term success of desensitization protocols. The studies utilizing protocol biopsies in desensitized patients also reported higher subclinical and chronic antibody-mediated rejection. An association between the strength of DSAs determined by median fluorescence intensity values of Luminex single-antigen beads and risk of rejection was observed. Two new agents, bortezomib, a proteasome inhibitor, and eculizumab, an anti-complement C5 antibody, were recently introduced to desensitization protocols. An alternative intervention is kidney paired exchange, which should be considered first for sensitized patients. © 2011 by the American Society of Nephrology

  10. Adenosine receptor desensitization and trafficking.

    Science.gov (United States)

    Mundell, Stuart; Kelly, Eamonn

    2011-05-01

    As with the majority of G-protein-coupled receptors, all four of the adenosine receptor subtypes are known to undergo agonist-induced regulation in the form of desensitization and trafficking. These processes can limit the ability of adenosine receptors to couple to intracellular signalling pathways and thus reduce the ability of adenosine receptor agonists as well as endogenous adenosine to produce cellular responses. In addition, since adenosine receptors couple to multiple signalling pathways, these pathways may desensitize differentially, while the desensitization of one pathway could even trigger signalling via another. Thus, the overall picture of adenosine receptor regulation can be complex. For all adenosine receptor subtypes, there is evidence to implicate arrestins in agonist-induced desensitization and trafficking, but there is also evidence for other possible forms of regulation, including second messenger-dependent kinase regulation, heterologous effects involving G proteins, and the involvement of non-clathrin trafficking pathways such as caveolae. In this review, the evidence implicating these mechanisms is summarized for each adenosine receptor subtype, and we also discuss those issues of adenosine receptor regulation that remain to be resolved as well as likely directions for future research in this field. Copyright © 2010 Elsevier B.V. All rights reserved.

  11. Systematic Desensitization as Training in Self-Control

    Science.gov (United States)

    Goldfried, Marvin R.

    1971-01-01

    A description of a mediational model to explain the effectiveness of desensitization and a discussion of the available corroborative research findings for this alternative explanation are given. Also, specific procedural modifications for systematic desensitization are suggested. (Author)

  12. Desensitization to clopidogrel: a tailor-made protocol.

    Science.gov (United States)

    Barreira, P; Cadinha, S; Malheiro, D; Moreira da Silva, J P

    2014-01-01

    Clopidogrel is an antiplatelet drug widely used for treatment and prevention of a variety of cardiovascular diseases. We report a successful desensitization to clopidogrel in a 70-year-old Caucasian man with delayed hypersensitivity (HS) reaction. He developed lip, hand and foot swelling, erythematous papular non-pruritic lesions and arthralgias 2 weeks after starting treatment with clopidogrel 75 mg/d. A 3-hour desensitization protocol was started, achieving a cumulative dose of 154 mg without any reaction, and a daily dose of 75 mg was recommended. On the 4th day, the patient developed skin lesions similar to the previously described. He was treated with topical steroids and oral antihistamines, and the daily dose of clopidogrel was reduced to 20 mg. A new desensitization protocol was established, with a slow dose increment, according to the patient's response. It was only possible to achieve the dose of 75 mg/d after 2 months. Although well tolerated by most patients, HS reactions with clopidogrel may occur and desensitization is rising as a safe alternative in those patients. In delayed reactions with cutaneous lesions, a slower desensitization protocol may be necessary, as in this case.

  13. Rituximab desensitization in three patients with severe rituximab allergy.

    Science.gov (United States)

    Öztürk, Erman; Özyiğit, Leyla Pur; Öztürk, Ayşe Bilge; Akay, Meltem Olga; Çetiner, Mustafa; Ferhanoğlu, Burhan

    Rituximab is a chimeric monoclonal antibody that targets CD20 positive B cells and has a positive effect on both overall and progression-free survival in B-cell lymphoid malignancies. Combination rituximab with chemotherapy treatment provide survival improvement. Although rituximab is an important treatment option in hematological malignancies, the risk of allergic reactions is high. These reactions are usually IgE-mediated and can be varied in regard of severity from urticaria to anaphylaxis. It is an option to interrupt the treatment and ommit rituximab therapy who had allergic reactions. Drug desensitization is another option and successful results have been reported by applying desensitization to such reactions. Drug desensitization alters the immune response to induce a state of temporary clinical tolerance to the allergic drug by giving gradual increasing of doses of drug at fixed time intervals. Herein, we present 3 cases successfully treated with rituximab desensitization. The cases were using rituximab with the diagnosis of Burkitt lymphoma, follicular lymphoma, and marginal zone lymphoma, respectively. Two cases had grade 2 and 1 case had grade 3 systemic allergic reaction with rituximab. There was no known allergy history in all 3 cases. All patients tolerated the desensitization protocol. The subsequent treatments of the patients were also given by desensitization protocol. A total of 12 desensitizations were administered to 3 cases. No severe or life-threating reactions were observed in subsequent applications. To date applying desensitization protocols ensure rituximab treatment safely. Rituximab desensitization can be performed at trained allergy centers, and it may be an appropriate option for rituximab allergic patients. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Quantitative analysis of enamel on debonded orthodontic brackets.

    Science.gov (United States)

    Cochrane, Nathan J; Lo, Thomas W G; Adams, Geoffrey G; Schneider, Paul M

    2017-09-01

    Iatrogenic damage to the tooth surface in the form of enamel tearouts can occur during removal of fixed orthodontic appliances. The aim of this study was to assess debonded metal and ceramic brackets attached with a variety of bonding materials to determine how frequently this type of damage occurs. Eighty-one patients close to finishing fixed orthodontic treatment were recruited. They had metal brackets bonded with composite resin and a 2-step etch-and-bond technique or ceramic brackets bonded with composite resin and a 2-step etch-and- bond technique, and composite resin with a self-etching primer or resin-modified glass ionomer cement. Debonded brackets were examined by backscattered scanning electron microscopy with energy dispersive x-ray spectroscopy to determine the presence and area of enamel on the base pad. Of the 486 brackets collected, 26.1% exhibited enamel on the bonding material on the bracket base pad. The incidences of enamel tearouts for each group were metal brackets, 13.3%; ceramic brackets, 30.2%; composite resin with self-etching primer, 38.2%; and resin-modified glass ionomer cement, 21.2%. The percentage of the bracket base pad covered in enamel was highly variable, ranging from 0% to 46.1%. Enamel damage regularly occurred during the debonding process with the degree of damage being highly variable. Damage occurred more frequently when ceramic brackets were used (31.9%) compared with metal brackets (13.3%). Removal of ceramic brackets bonded with resin-modified glass ionomer cement resulted in less damage compared with the resin bonding systems. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  15. GABAB receptor phosphorylation regulates KCTD12-induced K+ current desensitization

    DEFF Research Database (Denmark)

    Adelfinger, L; Turecek, R; Ivankova, K

    2014-01-01

    released from the G-protein. Receptor-activated K+ currents desensitize in the sustained presence of agonist to avoid excessive effects on neuronal activity. Desensitization of K+ currents integrates distinct mechanistic underpinnings. GABAB receptor activity reduces protein kinase-A activity, which...... reduces phosphorylation of serine-892 in GABAB2 and promotes receptor degradation. This form of desensitization operates on the time scale of several minutes to hours. A faster form of desensitization is induced by the auxiliary subunit KCTD12, which interferes with channel activation by binding to the G......-protein βγ subunits. Here we show that the two mechanisms of desensitization influence each other. Serine-892 phosphorylation in heterologous cells rearranges KCTD12 at the receptor and slows KCTD12-induced desensitization. Likewise, protein kinase-A activation in hippocampal neurons slows fast...

  16. Relationship Factors in Desensitization: A Persistent Trend

    Science.gov (United States)

    Nawas, M. Mike; Pucel, John C.

    1971-01-01

    The aim of the study was to explore the relevance to the outcome of desensitization of same-sex and opposite-sex pairings of subjects and experimenters. It was concluded that desensitization is independent of the sex pairing of subject and experimenter. (Author)

  17. Characterization of phosphorylated beta-adrenergic receptors from desensitized turkey erythrocytes

    International Nuclear Information System (INIS)

    Rebar, R.; Crooke, S.T.; Stadel, J.M.

    1986-01-01

    Catecholamine-induced desensitization of turkey erythrocyte (TE) adenylate cyclase results in a 40-50 percent decrease in agonist stimulated cyclase activity. Desensitization is accompanied by decreased mobility on SDS-PAGE of beta-adrenergic receptor (BAR) proteins photoaffinity labeled with [ 125 I]-p-azidobenzylcarazolol compared to control. Using a low crosslinked gel, the M/sub r/ = 42,000 band of BAR from desensitized TE was further resolved into a doublet compared to a single M/sub r/ = 38,000 band for control. The formation of the doublet appears to correlate with the amount of adenylate cyclase desensitization. Preincubating TE for 20 hr at 37 0 C with 32 P-/sub i/ labels BAR. 32 P-BAR was partially purified by affinity chromatography over alprenolol-Sepharose. Limited digest peptide maps of 32 P-BAR using papain identified a unique peptide (M/sub r/ = 2800) from BAR of desensitized TE which was absent in control. This unique 32 P-peptide was found only in the upper band of the doublet of BAR from desensitized TE. These data indicate that BAR is not uniformly phosphorylated following agonist-induced desensitization of TE and identify a peptide of BAR which is a site of phosphorylation correlating with desensitization of TE adenylate cyclase

  18. Aspirin Desensitization in Patients With Coronary Artery Disease: Results of the Multicenter ADAPTED Registry (Aspirin Desensitization in Patients With Coronary Artery Disease).

    Science.gov (United States)

    Rossini, Roberta; Iorio, Annamaria; Pozzi, Roberto; Bianco, Matteo; Musumeci, Giuseppe; Leonardi, Sergio; Lettieri, Corrado; Bossi, Irene; Colombo, Paola; Rigattieri, Stefano; Dossena, Cinzia; Anzuini, Angelo; Capodanno, Davide; Senni, Michele; Angiolillo, Dominick J

    2017-02-01

    There are limited data on aspirin (ASA) desensitization for patients with coronary artery disease. The aim of the present study was to assess the safety and efficacy of a standard rapid desensitization protocol in patients with ASA sensitivity undergoing coronary angiography. This is a prospective, multicenter, observational study including 7 Italian centers including patients with a history of ASA sensitivity undergoing coronary angiography with intent to undergo percutaneous coronary intervention. A total of 330 patients with history of ASA sensitivity with known/suspected stable coronary artery disease or presenting with an acute coronary syndrome, including ST-segment-elevation myocardial infarction were enrolled. Adverse effects to aspirin included urticaria (n=177, 53.6%), angioedema (n=69, 20.9%), asthma (n=65, 19.7%), and anaphylactic reaction (n=19, 5.8%). Among patients with urticaria/angioedema, 13 patients (3.9%) had a history of idiopathic chronic urticaria. All patients underwent a rapid ASA (5.5 hours) desensitization procedure. The desensitization procedure was performed before cardiac catheterization in all patients, except for those (n=78, 23.6%) presenting with ST-segment-elevation myocardial infarction who underwent the desensitization after primary percutaneous coronary intervention. Percutaneous coronary intervention was performed in 235 patients (71%) of the overall study population. The desensitization procedure was successful in 315 patients (95.4%) and in all patients with a history of anaphylactic reaction. Among the 15 patients (4.6%) who did not successfully respond to the desensitization protocol, adverse reactions were minor and responded to treatment with corticosteroids and antihistamines. Among patients with successful in-hospital ASA desensitization, 253 patients (80.3%) continued ASA for at least 12 months. Discontinuation of ASA in the 62 patients (19.7%) who had responded to the desensitization protocol was because of medical

  19. Comparison of galvanic corrosion potential of metal injection molded brackets to that of conventional metal brackets with nickel-titanium and copper nickel-titanium archwire combinations.

    Science.gov (United States)

    Varma, D Praveen Kumar; Chidambaram, S; Reddy, K Baburam; Vijay, M; Ravindranath, D; Prasad, M Rajendra

    2013-05-01

    The aim of the study is to investigate the galvanic corrosion potential of metal injection molding (MIM) brackets to that of conventional brackets under similar in vitro conditions with nickel-titanium and copper nickel-titanium archwires. Twenty-five maxillary premolar MIM stainless steel brackets and 25 conventional stainless steel brackets and archwires, 0.16 inch, each 10 mm length, 25 nickeltitanium wires, 25 copper nickel-titanium wires were used. They were divided into four groups which had five samples each. Combination of MIM bracket with copper nickel-titanium wire, MIM bracket with nickel-titanium wire and conventional stainless steel brackets with copper nickel-titanium wire and conventional stainless steel brackets with nickel-titanium wires which later were suspended in 350 ml of 1 M lactic acid solution media. Galvanic corrosion potential of four groups were analyzed under similar in vitro conditions. Precorrosion and postcorrosion elemental composition of MIM and conventional stainless steel bracket by scanning electron microscope (SEM) with energy dispersive spectroscope (EDS) was done. MIM bracket showed decreased corrosion susceptibility than conventional bracket with copper nickeltitanium wire. Both MIM and conventional bracket showed similar corrosion resistance potential in association with nickel-titanium archwires. It seems that both brackets are more compatible with copper nickel-titanium archwires regarding the decrease in the consequences of galvanic reaction. The EDS analysis showed that the MIM brackets with copper nickel-titanium wires released less metal ions than conventional bracket with copper nickeltitanium wires. MIM brackets showed decreased corrosion susceptibility, copper nickel-titanium archwires are compatible with both the brackets than nickel-titanium archwires. Clinically MIM and conventional brackets behaved more or less similarly in terms of corrosion resistance. In order to decrease the corrosion potential of MIM

  20. Systematic Desensitization Of Test Anxiety: A Comparison Of Group And Individual Treatment

    Science.gov (United States)

    Scissons, Edward H.; Njaa, Lloyd J.

    1973-01-01

    The results indicate the effectiveness of both individual desensitization and group desensitization in the treatment of high test anxiety. More research is needed in comparing the effectiveness of group desensitization and individual desensitization with intratreatment variables. (Author)

  1. Recovery from desensitization of IgE-dependent responses in human lung mast cells.

    Science.gov (United States)

    Lewis, A; MacGlashan, D W; Suvarna, S K; Peachell, P T

    2017-08-01

    Clinical desensitization and oral food immunotherapy are therapeutic interventions that allow individuals who react adversely to an allergen (drug or food) to be made tolerant to the allergen. However, tolerance is brief, and allergen hypersensitivity can recur within days following allergen withdrawal. We hypothesize that the reason these treatments are temporary reflects rapid recovery of mast cells from a desensitized state. We sought to test this. Desensitization of IgE-mediated histamine release from human lung mast cells was explored by methods that partially replicate the pattern of treatment during clinical desensitization. Specific and non-specific desensitization and changes in surface IgE were examined following desensitization. Recovery from desensitization was also studied. Desensitization of mast cell responses was readily induced with concentrations of antigen or anti-IgE that were suboptimal for secretion. There was little or no non-specific desensitization when lung mast cells were exposed to antigens. There was no loss of cell surface IgE following desensitization. Removing the desensitizing stimulus from the media following desensitization allowed the cells to recover with half-point of recovery of ~1.5 days and complete recovery after 5 days. Both the functional response and histamine content recovered within this time frame. The recovery appeared possible because both antigens and anti-IgE dissociated rapidly from cells after washing to remove excess stimulus. Human lung mast cells readily recover from a desensitized state following removal of desensitizing antigen. This finding provides a potential explanation for the ephemeral nature of clinical desensitization. © 2017 John Wiley & Sons Ltd.

  2. 21 CFR 872.5470 - Orthodontic plastic bracket.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Orthodontic plastic bracket. 872.5470 Section 872...) MEDICAL DEVICES DENTAL DEVICES Therapeutic Devices § 872.5470 Orthodontic plastic bracket. (a) Identification. An orthodontic plastic bracket is a plastic device intended to be bonded to a tooth to apply...

  3. The effect of pre-cure bracket movement on shear bond strength during placement of orthodontic brackets, an in vitro study.

    Science.gov (United States)

    Tam, Byron; Bollu, Prashanti; Chaudhry, Kishore; Subramani, Karthikeyan

    2017-10-01

    The purpose of this study was to determine the influence of linear and rotational pre-cure bracket displacement during the bonding procedure on shear bond strength (SBS) of orthodontic brackets. Stainless steel orthodontic premolar brackets were bonded to the buccal surfaces of 50 human pre-molars with a conventional two-step bonding protocol. Extracted human pre-molars were divided into 5 groups (n=10/group). In the Control Group, the brackets were bonded with no pre-cure bracket displacement or rotation. The Rotation Group was bonded with 45 degrees of pre-cure rotation. The Displacement Group was bonded with 2mm pre-cure linear displacement. The Rotation-Displacement Group was bonded with pre-cure movements of 45º counter-clockwise rotation and 2mm displacement. The Slippage Group was bonded with 2mm each of mesial and distal pre-cure linear displacement. Photo-activation was carried out on the lateral sides of the bracket. Shear debonding force was measured, 24 hours after initial bonding, with an Instron universal testing machine using a knife-edged chisel. Data was analyzed using one-way ANOVA test. Adhesive Remnant Index (ARI) was scored under 15x magnification. The ARI data was analyzed using the Chi-square test ( p -value bracket displacements do not appear to effect the shear bond strength of orthodontic brackets. Key words: Shear bond strength, orthodontic bracket, displacement, rotation, adhesive remnant index, pre-cure movement.

  4. Adhesives for orthodontic bracket bonding

    Directory of Open Access Journals (Sweden)

    Déborah Daniella Diniz Fonseca

    2010-04-01

    Full Text Available The advent of acid etching, introduced by Buonocore in 1955, brought the possibility of bonding between the bracket base and enamel, contributing to more esthetic and conservative orthodontics. This direct bracket bonding technique has brought benefits such as reduced cost and time in performing the treatment, as well as making it easier to perform oral hygiene. The aim of this study was to conduct a survey of published studies on orthodontic bracket bonding to dental enamel. It was verified that resin composites and glass ionomer are the most studied and researched materials for this purpose. Resin-modified glass ionomer, with its biocompatibility, capacity of releasing fluoride and no need for acid etching on the tooth structure, has become increasingly popular among dentists. However, due to the esthetic and mechanical properties of light polymerizable resin composite, it continues to be one of the adhesives of choice in the bracket bonding technique and its use is widely disseminated.

  5. Are torque values of preadjusted brackets precise?

    Directory of Open Access Journals (Sweden)

    Alessandra Motta Streva

    Full Text Available OBJECTIVE: The aim of the present study was to verify the torque precision of metallic brackets with MBT prescription using the canine brackets as the representative sample of six commercial brands. MATERIAL AND METHODS: Twenty maxillary and 20 mandibular canine brackets of one of the following commercial brands were selected: 3M Unitek, Abzil, American Orthodontics, TP Orthodontics, Morelli and Ortho Organizers. The torque angle, established by reference points and lines, was measured by an operator using an optical microscope coupled to a computer. The values were compared to those established by the MBT prescription. RESULTS: The results showed that for the maxillary canine brackets, only the Morelli torque (-3.33º presented statistically significant difference from the proposed values (-7º. For the mandibular canines, American Orthodontics (-6.34º and Ortho Organizers (-6.25º presented statistically significant differences from the standards (-6º. Comparing the brands, Morelli presented statistically significant differences in comparison with all the other brands for maxillary canine brackets. For the mandibular canine brackets, there was no statistically significant difference between the brands. CONCLUSIONS: There are significant variations in torque values of some of the brackets assessed, which would clinically compromise the buccolingual positioning of the tooth at the end of orthodontic treatment.

  6. Comment on the Status of Systematic Desensitization

    Science.gov (United States)

    McGlynn, F. Dudley; Smitherman, Todd A.; Gothard, Kelly D.

    2004-01-01

    Articles about systematic desensitization that appeared in mainstream behavior therapy journals between the years 1970 and 2002 were counted. Graphic displays of the data point to a sudden and lasting decline of interest in systematic desensitization among academics and researchers. A questionnaire concerning clinical use of orthodox systematic…

  7. The clinical dilemma of "silent desensitization" in aspirin-exacerbated respiratory disease.

    Science.gov (United States)

    White, Andrew A; Bosso, John V; Stevenson, Donald D

    2013-01-01

    Aspirin desensitization is a treatment option for patients with aspirin-exacerbated respiratory disease (AERD). Some patients with an excellent history of aspirin or nonsteroidal anti-inflammatory drug (NSAID) reactions have negative aspirin challenges/desensitization. This study discusses the clinical entity of silent desensitization in AERD and the dilemma that this presents to the practicing allergist/immunologist. We discuss a series of patients with a strong history of NSAID reactions who initially underwent a negative challenge/silent desensitization. These patients were subsequently proven to have AERD after a second positive aspirin challenge. Silent desensitization is an uncommon but important outcome to recognize in AERD. Clinicians performing aspirin desensitization should understand that this can occur and consider a second confirmatory aspirin challenge in some patients.

  8. [Self-ligating edgewise brackets. An overview].

    Science.gov (United States)

    Katsaros, C; Dijkman, J F

    2003-01-01

    During the last years both the manufactures and the orthodontists seem to show an increased interest in self-ligating brackets. This paper aims to present the history of self-ligating systems, to describe the three mostly used bracketsystems and to review the relevant literature. It seems from the existing data that self-ligating brackets have certain advantages over conventionally ligated brackets. However, the data are still thin and a high need for well designed clinical trials exist.

  9. Efficacy, outcomes, and cost-effectiveness of desensitization using IVIG and rituximab.

    Science.gov (United States)

    Vo, Ashley A; Petrozzino, Jeffrey; Yeung, Kai; Sinha, Aditi; Kahwaji, Joseph; Peng, Alice; Villicana, Rafael; Mackowiak, John; Jordan, Stanley C

    2013-03-27

    Transplantation rates are very low for the broadly sensitized patient (panel reactive antibody [PRA]>80%; HS). Here, we examine the efficacy, outcomes, and cost-effectiveness of desensitization using high-dose intravenous immunoglobulin (IVIG) and rituximab to improve transplantation rates in HS patients. From July 2006 to December 2011, 207 HS (56 living donors/151 deceased donors) patients (donor-specific antibody positive, PRA>80%) were desensitized using IVIG and rituximab. After desensitization, responsive patients proceeded to transplantation with an acceptable crossmatch. Cost and outcomes of desensitization were compared with dialysis. Of the 207 treated patients, 146 (71%) were transplanted. At 48 months, patient and graft survival by Kaplan-Meier were 95% and 87.5%, respectively. The total 3-year cost for patients treated in the desensitization arm was $219,914 per patient compared with $238,667 per patient treated in the dialysis arm. Thus, each patient treated with desensitization is estimated to save the U.S. healthcare system $18,753 in 2011 USD. Overall, estimated patient survival at the end of 3 years was 96.6% for patients in the desensitization arm of the model (based on Cedars-Sinai survival rate) compared with 79.0% for an age, end-stage renal disease etiology, and PRA matched group of patients remaining on dialysis during the study period. We conclude that desensitization with IVIG+rituximab is clinically and cost-effective, with both financial savings and an estimated 17.6% greater probability of 3-year survival associated with desensitization versus dialysis alone. However, the benefits of desensitization and transplantation are limited by organ availability and allocation policies.

  10. Aspirin desensitization in aspirin-sensitive asthma: failure to maintain a desensitized state during prolonged therapy.

    Science.gov (United States)

    Dankner, R E; Wedner, H J

    1983-11-01

    A patient with a history of asthma induced by acetylsalicylic acid (ASA) was found to be ASA sensitive when orally challenged with ASA. She was successfully desensitized using incremental doses of ASA given orally and maintained on ASA or other nonsteroidal antiinflammatory (NSAI) agents for the treatment of arthritis. After 6 months of uninterrupted therapy the patient developed asthmatic symptoms that were related to ASA and NSAI drug therapy. Although desensitization may be achieved in patients with ASA-sensitive asthma, sensitivity may recur despite continuous therapy.

  11. Laser debonding of ceramic orthodontic brackets: a theoretical approach

    Science.gov (United States)

    Kearney, Kristine L.; Marangoni, Roy D.; Rickabaugh, Jeff L.

    1992-06-01

    Ceramic brackets are an esthetic substitute for conventional stainless steel brackets in orthodontic patients. However, ceramic brackets are more brittle and have higher bond strengths which can lead to bracket breakage and enamel damage during debonding. It has been demonstrated that various lasers can facilitate ceramic bracket removal. One mechanism with the laser is through the softening of the bracket adhesive. The high energy density from the laser on the bracket and adhesive can have a resultant deleterious thermal effect on the pulp of the tooth which may lead to pulpal death. A theoretical computer model of bracket, adhesive, enamel and dentin has been generated for predicting heat flow through this system. Heat fluxes at varying intensities and modes have been input into the program and the resultant temperatures at various points or nodes were determined. Further pursuit should lead to optimum parameters for laser debonding which would have minimal effects on the pulp.

  12. Desensitization of animals to the inflammatory effects of ultraviolet radiation is mediated through mechanisms which are distinct from those responsible for endotoxin tolerance

    International Nuclear Information System (INIS)

    Gahring, L.C.; Daynes, R.A.

    1986-01-01

    Desensitization to the inflammatory properties of either UVR or LPS appears to be controlled at the site of interaction between the tissues capable of producing epidermal-derived thymocyte-activating factor (ETAF)/IL 1 (epidermal keratinocytes or reticuloendothelial cells, respectively) and the exogenous inflammatory stimulus. Peritoneal macrophages obtained from LPS-desensitized mice were found to have a markedly reduced capacity to secrete ETAF/IL 1 in vitro when compared to peritoneal exudate cells (PEC) obtained from normal mice. In parallel with this decreased secretory potential by PEC was the appearance of membrane-associated IL 1 was not found to be present on PEC obtained from normal mice. Keratinocytes obtained from the skin of normal mice or keratinocytes isolated from the irradiated skin site of UVR-desensitized mice were both found to secrete high levels of ETAF/IL 1 constitutively in vitro. Furthermore, both sources of keratinocytes also expressed membrane-associated forms of ETAF/IL 1 constitutively. Therefore, unlike LPS desensitization, the phenomenon of UVR desensitization does not appear to induce changes in the ability of keratinocytes to secrete soluble forms or to express membrane forms of ETAF/IL 1. UVR desensitization may be a result of the inability of ETAF/IL 1 generated within the skin to reach the various IL 1 responsive target cells throughout the body, or may result from the impaired ability of UVR to stimulate ETAF/IL 1 production due to changes in the structure of the skin of chronically UVR-exposed animals

  13. Nursing Care of Patients Undergoing Chemotherapy Desensitization: Part II.

    Science.gov (United States)

    Jakel, Patricia; Carsten, Cynthia; Carino, Arvie; Braskett, Melinda

    2016-04-01

    Chemotherapy desensitization protocols are safe, but labor-intensive, processes that allow patients with cancer to receive medications even if they initially experienced severe hypersensitivity reactions. Part I of this column discussed the pathophysiology of hypersensitivity reactions and described the development of desensitization protocols in oncology settings. Part II incorporates the experiences of an academic medical center and provides a practical guide for the nursing care of patients undergoing chemotherapy desensitization.
.

  14. Useless brackets in arithmetic expressions with mixed operations

    OpenAIRE

    Gunnarsson, Robert; Hernell, Bernt; Sönnerhed, Wang Wei

    2012-01-01

    There can be different intentions with brackets in mathematical expressions. It has previously been suggested that mathematically useless brackets can be educationally useful when learning the order of operations in expressions with mixed operations. This paper reports how students (12-13 years) deal with the implicit mental conflict between brackets as a necessary part of the order of operations and brackets to emphasize precedence. The students taking part in this quasi-experimental study w...

  15. Nursing Care of Patients Undergoing Chemotherapy Desensitization: Part I.

    Science.gov (United States)

    Jakel, Patricia; Carsten, Cynthia; Braskett, Melinda; Carino, Arvie

    2016-02-01

    Hypersensitivity reactions to chemotherapeutic agents can cause the discontinuation of first-line therapies. Chemotherapy desensitization is a safe, but labor-intensive, process to administer these important medications. A desensitization protocol can enable a patient to receive the entire target dose of a medication, even if the patient has a history of severe infusion reactions. In this article, the authors explain the pathophysiology of hypersensitivity reactions and describe the recent development of desensitization protocols in oncology. In part II of this article, which will appear in the April 2016 issue of the Clinical Journal of Oncology Nursing, the authors will give a detailed account of how a desensitization protocol is performed at an academic medical center.
.

  16. Bracketing as a skill in conducting unstructured qualitative interviews.

    Science.gov (United States)

    Sorsa, Minna Anneli; Kiikkala, Irma; Åstedt-Kurki, Päivi

    2015-03-01

    To provide an overview of bracketing as a skill in unstructured qualitative research interviews. Researchers affect the qualitative research process. Bracketing in descriptive phenomenology entails researchers setting aside their pre-understanding and acting non-judgementally. In interpretative phenomenology, previous knowledge is used intentionally to create new understanding. A literature search of bracketing in phenomenology and qualitative research. This is a methodology paper examining the researchers' impact in creating data in creating data in qualitative research. Self-knowledge, sensitivity and reflexivity of the researcher enable bracketing. Skilled and experienced researchers are needed to use bracketing in unstructured qualitative research interviews. Bracketing adds scientific rigour and validity to any qualitative study.

  17. Desensitization for solid organ and hematopoietic stem cell transplantation.

    Science.gov (United States)

    Zachary, Andrea A; Leffell, Mary S

    2014-03-01

    Desensitization protocols are being used worldwide to enable kidney transplantation across immunologic barriers, i.e. antibody to donor HLA or ABO antigens, which were once thought to be absolute contraindications to transplantation. Desensitization protocols are also being applied to permit transplantation of HLA mismatched hematopoietic stem cells to patients with antibody to donor HLA, to enhance the opportunity for transplantation of non-renal organs, and to treat antibody-mediated rejection. Although desensitization for organ transplantation carries an increased risk of antibody-mediated rejection, ultimately these transplants extend and enhance the quality of life for solid organ recipients, and desensitization that permits transplantation of hematopoietic stem cells is life saving for patients with limited donor options. Complex patient factors and variability in treatment protocols have made it difficult to identify, precisely, the mechanisms underlying the downregulation of donor-specific antibodies. The mechanisms underlying desensitization may differ among the various protocols in use, although there are likely to be some common features. However, it is likely that desensitization achieves a sort of immune detente by first reducing the immunologic barrier and then by creating an environment in which an autoregulatory process restricts the immune response to the allograft. © 2014 The Authors. Immunological Reviews Published by John Wiley & Sons Ltd.

  18. Substance P receptor desensitization requires receptor activation but not phospholipase C

    International Nuclear Information System (INIS)

    Sugiya, Hiroshi; Putney, J.W. Jr.

    1988-01-01

    Previous studies have shown that exposure of parotid acinar cells to substance P at 37 degree C results in activation of phospholipase C, formation of [ 3 H]inositol 1,4,5-trisphosphate (IP 3 ), and persistent desensitization of the substance P response. In cells treated with antimycin in medium containing glucose, ATP was decreased to ∼20% of control values, IP 3 formation was completely inhibited, but desensitization was unaffected. When cells were treated with antimycin in the absence of glucose, cellular ATP was decreased to ∼5% of control values, and both IP 3 formation and desensitization were blocked. A series of substance P-related peptides increased the formation of [ 3 H]IP 3 and induced desensitization of the substance P response with a similar rank order of potencies. The substance P antagonist, [D-Pro 2 , D-Try 7,9 ]-substance P, inhibited substance P-induced IP 3 formation and desensitization but did not induce desensitization. These results suggest that the desensitization of substance P-induced IP 3 formation requires agonist activation of a P-type substance P receptor, and that one or more cellular ATP-dependent processes are required for this reaction. However, activation of phospholipase C and the generation of inositol phosphates does not seem to be a prerequisite for desensitization

  19. Higher Toda brackets and Massey products

    OpenAIRE

    Baues, Hans-Joachim; Blanc, David; Gondhali, Shilpa

    2015-01-01

    We provide a uniform definition of higher order Toda brackets in a general setting, covering the known cases of long Toda brackets for topological spaces and chain complexes and Massey products for differential graded algebras, among others.

  20. Evaluation of frictional forces of polycarbonate self-ligating brackets.

    Science.gov (United States)

    Fernandes, Daniel J; Miguel, José Augusto M; Quintão, Catia C A; Elias, Carlos N

    2010-01-01

    To evaluate the frictional forces generated by ceramic- (Opal, Ultradent) and glass-fiber-reinforced polycarbonate self-ligating brackets (Oyster, Gestenco) and compare the effectiveness of these ligatureless systems with glass-fiber-reinforced polycarbonate conventional brackets (Blonde, Gestenco). The hypothesis is that there is no difference between frictional forces generated by ceramic- and glass-fiber-reinforced polycarbonate self-ligating and glass-fiber-reinforced polycarbonate conventional brackets. Twelve preadjusted 0.022 3 0.028-inch maxillary canine brackets were tested, divided into three groups: Opal, Oyster, and Blonde. Frictional tests were conducted with the Emic DL 10000 testing machine with a 20 N loadcell for 40 seconds at a 0.5 cm/min speed. Each bracket-wire combination was tested five times. The data generated were analyzed by parametric analysis of variance (one-way ANOVA) and Bonferroni tests. Analysis of variance indicated significant differences for the three groups (Pfrictional forces of the Oyster glass-fiber-reinforced polycarbonate self-ligating brackets were significantly lower (37.0 ± 8.9 cN) than those of the Opal ceramic-reinforced polycarbonate self-ligating brackets (49.5 ± 10.1 cN), while the Blonde glass-fiber-reinforced conventional bracket frictional forces were 105.8 ± 6.4 cN. Oyster glass-fiber-reinforced polycarbonate brackets produced less friction than Opal ceramic-reinforced polycarbonate brackets. The polycarbonate ligatureless system showed significantly lower frictional forces compared to Blonde conventional polycarbonate brackets tied with elastomeric ligatures. The study rejected the initial hypothesis because there are significant differences of frictional forces among the tested systems. © 2010 BY QUINTESSENCE PUBLISHING CO, INC.

  1. Microbial complexes levels in conventional and self-ligating brackets.

    Science.gov (United States)

    Bergamo, Ana Zilda Nazar; Nelson-Filho, Paulo; Andrucioli, Marcela Cristina Damião; do Nascimento, Cássio; Pedrazzi, Vinícius; Matsumoto, Mírian Aiko Nakane

    2017-05-01

    The aims were to evaluate the levels of bacterial species in saliva and in situ and to assess whether the design of brackets influences the risk of developing periodontal disease. Twenty patients (13.3 mean age) were bonded with self-ligating brackets and a conventional bracket. Saliva was collected before bonding and 30 and 60 days after bonding. One sample of each bracket was removed 30 and 60 days after bonding. The analysis was determined by checkerboard DNA-DNA hybridization. The data was evaluated by the non-parametric test. A significant increase in the levels of bacterial species in the saliva occurred in 15 of the 22 analyzed species. The self-ligating brackets presented the highest incidence percentages for the orange and red complexes 60 days after bonding. In situ analyses showed different patterns according to the bracket design. The levels of Campylobacter rectus showed significant differences (p = 0.011) 60 days after bonding among the three brackets; the highest values were observed in the In-Ovation®R bracket. The bracket design seems to influence the levels of bacterial species involved in periodontal disease. Considering the wide variety of bacterial species, additional studies are needed to aid in the establishment of effective protocols to prevent the development of periodontal disease during orthodontic treatment. A dynamic alteration in the oral microbiota may lead to inflammatory reactions in the supporting soft and hard tissues. The different types of brackets interfere with bacterial adherence. Bracket design should be considered in orthodontic treatment.

  2. Linear odd Poisson bracket on Grassmann variables

    International Nuclear Information System (INIS)

    Soroka, V.A.

    1999-01-01

    A linear odd Poisson bracket (antibracket) realized solely in terms of Grassmann variables is suggested. It is revealed that the bracket, which corresponds to a semi-simple Lie group, has at once three Grassmann-odd nilpotent Δ-like differential operators of the first, the second and the third orders with respect to Grassmann derivatives, in contrast with the canonical odd Poisson bracket having the only Grassmann-odd nilpotent differential Δ-operator of the second order. It is shown that these Δ-like operators together with a Grassmann-odd nilpotent Casimir function of this bracket form a finite-dimensional Lie superalgebra. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  3. Heat Exchanger Support Bracket Design Calculations

    International Nuclear Information System (INIS)

    Rucinski, Russ

    1995-01-01

    This engineering note documents the design of the heat exchanger support brackets. The heat exchanger is roughly 40 feet long, 22 inches in diameter and weighs 6750 pounds. It will be mounted on two identical support brackets that are anchored to a concrete wall. The design calculations were done for one bracket supporting the full weight of the heat exchanger, rounded up to 6800 pounds. The design follows the American Institute of Steel Construction (AISC) Manual of steel construction, Eighth edition. All calculated stresses and loads on welds were below allowables.

  4. In vitro evaluation of frictional forces of two ceramic orthodontic brackets versus a stainless steel bracket in combination with two types of archwires.

    Science.gov (United States)

    Arash, Valiollah; Rabiee, Mahmoud; Rakhshan, Vahid; Khorasani, Sara; Sobouti, Farhad

    2015-01-01

    The aim of this study was to compare frictional forces between monocrystalline alumina (MA), polycrystalline alumina (PA), and stainless steel (SS) brackets with two SS wires: Rectangular and round. In this in vitro study, 60 0.022 brackets [20 PA (0° torque, Forestadent, Germany) and 20 MA (0° torque, Ormco, California, USA)] brackets plus 20 SS brackets (0° torque, Foretadent, Germany) and 60 SS archwires (30 rectangular 0.019 ×0.025 archwires and 30 round 0.018 archwires, Ortho Technology, USA) were used in subgroups of 10 from the combination of all brackets and all archwires. A universal testing machine (Instron, Model STM 250, Germany) was used to investigate the static frictional resistance. The angulation between the bracket and wire was 0°, and the wires were pulled through the slots at a crosshead speed of 10 mm/min. Two-way and one-way analyses of variance (ANOVA) and Tukey tests were used to analyze the data. Mean (SD) static frictional force for each group was as follows: MA + round: 3.47 (0.38); MA + rectangular: 4.05 (0.47); PA + round: 4.14 (0.37); PA + rectangular: 4.45 (0.65); SS + round: 3.28 (0.22); and SS + rectangular: 4.22 (0.61). Significant effects of bracket types (P = 0.001) and archwire types (P = 0.000) on the friction force were detected using ANOVA. Tukey test indicated significant differences between PA brackets with both SS and MA brackets (P brackets. The two archwires as well had significantly different effects (Tukey P = 0.000). Based on the present in-vitro study, the PA brackets might create higher frictional forces compared to both SS and MA brackets. The rectangular 0.019 ×0.025 archwire might create greater forces than round 0.018 archwire.

  5. In vitro evaluation of frictional forces of two ceramic orthodontic brackets versus a stainless steel bracket in combination with two types of archwires

    Science.gov (United States)

    Arash, Valiollah; Rabiee, Mahmoud; Rakhshan, Vahid; Khorasani, Sara; Sobouti, Farhad

    2015-01-01

    Purpose: The aim of this study was to compare frictional forces between monocrystalline alumina (MA), polycrystalline alumina (PA), and stainless steel (SS) brackets with two SS wires: Rectangular and round. Materials and Methods: In this in vitro study, 60 0.022 brackets [20 PA (0° torque, Forestadent, Germany) and 20 MA (0° torque, Ormco, California, USA)] brackets plus 20 SS brackets (0° torque, Foretadent, Germany) and 60 SS archwires (30 rectangular 0.019 ×0.025 archwires and 30 round 0.018 archwires, Ortho Technology, USA) were used in subgroups of 10 from the combination of all brackets and all archwires. A universal testing machine (Instron, Model STM 250, Germany) was used to investigate the static frictional resistance. The angulation between the bracket and wire was 0°, and the wires were pulled through the slots at a crosshead speed of 10 mm/min. Two-way and one-way analyses of variance (ANOVA) and Tukey tests were used to analyze the data. Results: Mean (SD) static frictional force for each group was as follows: MA + round: 3.47 (0.38); MA + rectangular: 4.05 (0.47); PA + round: 4.14 (0.37); PA + rectangular: 4.45 (0.65); SS + round: 3.28 (0.22); and SS + rectangular: 4.22 (0.61). Significant effects of bracket types (P = 0.001) and archwire types (P = 0.000) on the friction force were detected using ANOVA. Tukey test indicated significant differences between PA brackets with both SS and MA brackets (P brackets. The two archwires as well had significantly different effects (Tukey P = 0.000). Conclusions: Based on the present in-vitro study, the PA brackets might create higher frictional forces compared to both SS and MA brackets. The rectangular 0.019 ×0.025 archwire might create greater forces than round 0.018 archwire. PMID:26020037

  6. Degenerate odd Poisson bracket on Grassmann variables

    International Nuclear Information System (INIS)

    Soroka, V.A.

    2000-01-01

    A linear degenerate odd Poisson bracket (antibracket) realized solely on Grassmann variables is proposed. It is revealed that this bracket has at once three Grassmann-odd nilpotent Δ-like differential operators of the first, second and third orders with respect to the Grassmann derivatives. It is shown that these Δ-like operators, together with the Grassmann-odd nilpotent Casimir function of this bracket, form a finite-dimensional Lie superalgebra

  7. Using a Bracketed Analysis as a Learning Tool.

    Science.gov (United States)

    Main, Keith

    1995-01-01

    Bracketed analysis is an examination of experiences within a defined time frame or "bracket." It assumes the ability to learn from any source: behaviors, emotions, rational and irrational thought, insights, reflections, and reactions. A bracketed analysis to determine what went wrong with a grant proposal that missed deadlines…

  8. 3D-printed orthodontic brackets - proof of concept.

    Science.gov (United States)

    Krey, Karl-Friedrich; Darkazanly, Nawras; Kühnert, Rolf; Ruge, Sebastian

    Today, orthodontic treatment with fixed appliances is usually carried out using preprogrammed straight-wire brackets made of metal or ceramics. The goal of this study was to determine the possibility of clinically implementing a fully digital workflow with individually designed and three-dimensionally printed (3D-printed) brackets. Edgewise brackets were designed using computer-aided design (CAD) software for demonstration purposes. After segmentation of the malocclusion model generated based on intraoral scan data, the brackets were digitally positioned on the teeth and a target occlusion model created. The thus-defined tooth position was used to generate a template for an individualized arch form in the horizontal plane. The base contours of the brackets were modified to match the shape of the tooth surfaces, and a positioning guide (fabricated beforehand) was used to ensure that the brackets were bonded at the correct angle and position. The brackets, positioning guide, and retainer splint, digitally designed on the target occlusion model, were 3D printed using a Digital Light Processing (DLP) 3D printer. The archwires were individually pre-bent using the template. In the treatment sequence, it was shown for the first time that, in principle, it is possible to perform treatment with an individualized 3D-printed brackets system by using the proposed fully digital workflow. Technical aspects of the system, problems encountered in treatment, and possible future developments are discussed in this article.

  9. Agonist-induced desensitization of adenylyl cyclase in Y1 adrenocortical tumor cells

    International Nuclear Information System (INIS)

    Olson, M.F.; Tsao, J.; Pon, D.J.; Schimmer, B.P.

    1991-01-01

    Y1 adrenocortical tumor cells (Y1DS) and Y1 mutants resistant to ACTH-induced desensitization of adenylyl cyclase (Y1DR) were transfected with a gene encoding the mouse beta 2-adrenergic receptor (beta 2-AR). Transfectants expressed beta 2-ARs that were able to stimulate adenylyl cyclase activity and steroid biosynthesis. These transfectants were used to explore the basis for the DR mutation in Y1 cells. The authors demonstrate that beta-adrenergic agonists desensitize the adenylyl cyclase system in transfected Y1DS cells whereas transfected Y1DR cells are resistant to desensitization by beta-adrenergic agonists. The fate of the beta 2-ARs during desensitization was evaluated by photoaffinity labelling with [125I]iodocyanopindolol diazerine. Desensitization of Y1DS transfectants was accompanied by a modest loss in receptor density that was insufficient to account for the complete loss of responsiveness to beta-adrenergic agonists. The extent of receptor loss induced by beta-adrenergic agonists in Y1DR transfectants exceeded that in the Y1DS transfectants indicating that the mutation which protects Y1DR cells from agonist-induced desensitization is prior to receptor down-regulation in the desensitization pathway. From these results we infer that ACTH and isoproterenol desensitize adenylyl cyclase by a common pathway and that receptor loss is not a major component of the desensitization process in these cells

  10. Physical and adhesive properties of dental enamel after radiotherapy and bonding of metal and ceramic brackets.

    Science.gov (United States)

    Santin, Gabriela Cristina; Palma-Dibb, Regina Guenka; Romano, Fábio Lourenço; de Oliveira, Harley Francisco; Nelson Filho, Paulo; de Queiroz, Alexandra Mussolino

    2015-08-01

    The increasing success rates for cancer patients treated with radiotherapy and the frequent occurrence of tooth loss during treatment have led to an increased demand for orthodontic treatment after radiotherapy. The aim of this study was to evaluate tooth enamel of irradiated teeth after the bonding and debonding of metal and ceramic brackets. Ten permanent molars were cut into enamel fragments measuring 1 mm(2) and divided into an irradiated group (total dose of 60 Gy) and a nonirradiated group. The fragments were subjected to microshear testing to evaluate whether radiotherapy altered the strength of the enamel. Furthermore, 90 prepared premolars were divided into 6 groups and subgroups (n = 15): group 1, nonirradiated and nonaged; group 2, nonirradiated and aged (thermal cycled); group 3, irradiated and aged; each group was divided into 2 subgroups: metallic and ceramic brackets. After thermal cycling and radiotherapy, the brackets were bonded onto the specimens with Transbond XT (3M Unitek, Monrovia, Calif). After 24 hours, the specimens were subjected to the shear tests. Images of the enamel surfaces were classified using the adhesive remnant index. The composite resin-enamel interface was also evaluated. Enamel fragments subjected to radiation had lower strength than did the nonirradiated samples (P enamel interface, resin tags were more extensive on irradiated tooth enamel. Radiation decreased tooth enamel strength, and the specimens treated with radiotherapy had higher frequencies of adhesive failure between the bracket and the composite resin as well as more extensive tags. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  11. A comparative assessment of torque generated by lingual and conventional brackets

    NARCIS (Netherlands)

    Sifakakis, I.; Pandis, N.; Makou, M.; Eliades, T.; Katsaros, C.; Bourauel, C.

    2013-01-01

    The aim of this study was to assess the effect of bracket type on the labiopalatal moments generated by lingual and conventional brackets. Incognito lingual brackets (3M Unitek), STb lingual brackets (Light Lingual System; ORMCO), In-Ovation L lingual brackets (DENTSPLY GAC), and conventional 0.018

  12. Performing Aspirin Desensitization in Aspirin-Exacerbated Respiratory Disease.

    Science.gov (United States)

    Waldram, Jeremy D; Simon, Ronald A

    2016-11-01

    Aspirin-exacerbated respiratory disease (AERD) is characterized by chronic rhinosinusitis with nasal polyps, asthma, and reactions to cyclooxygenase-1-inhibiting drugs. This condition is often refractory to standard medical treatments and results in aggressive nasal polyposis that often requires multiple sinus surgeries. Aspirin desensitization followed by daily aspirin therapy is an important treatment option, and its efficacy has been validated in multiple research studies. Aspirin desensitization is not without risk, but specific protocols and recommendations exist to mitigate the risk. Most patients with AERD can undergo aspirin desensitization in an outpatient setting under the supervision of an allergist. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Long-term sinonasal outcomes of aspirin desensitization in aspirin exacerbated respiratory disease.

    Science.gov (United States)

    Cho, Kyu-Sup; Soudry, Ethan; Psaltis, Alkis J; Nadeau, Kari C; McGhee, Sean A; Nayak, Jayakar V; Hwang, Peter H

    2014-10-01

    This study aimed to assess sinonasal outcomes in patients with aspirin exacerbated respiratory disease (AERD) undergoing aspirin desensitization following endoscopic sinus surgery (ESS). Case series with chart review. University hospital. A retrospective review of sinonasal outcomes was conducted for 30 AERD patients undergoing aspirin desensitization and maintenance therapy following ESS. Sinonasal outcomes were prospectively assessed by the Sinonasal Outcomes Test-22 (SNOT-22) and endoscopic polyp grading system. Data were collected preoperatively, 1 and 4 weeks postsurgery (before desensitization), and 1, 6, 12, 18, 24, and 30 months after aspirin desensitization. Twenty-eight of 30 patients (93.3%) successfully completed aspirin desensitization, whereas 2 of 30 (6.7%) were unable to complete desensitization due to respiratory intolerance. Of the 21 patients who successfully completed a minimum of 24 weeks of follow-up, 20 (95.2%) patients demonstrated sustained endoscopic and symptomatic improvement for a median follow-up period of 33 months. After surgical treatment but before desensitization, patients experienced significant reductions in SNOT-22 and polyp grade scores. In the first 6 months after aspirin desensitization, patients experienced further significant reductions in SNOT-22 scores, whereas polyp grade remained stable. The improvements in symptom endoscopic scores were preserved throughout the follow-up period after desensitization. No patients required additional sinus surgery. One patient had to discontinue aspirin therapy due to gastrointestinal side effects. No other adverse reactions to aspirin were noted. Aspirin desensitization following ESS appears to be a well-tolerated and effective adjunctive therapy for long-term control of nasal polyposis in patients with AERD. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2014.

  14. Progress in Desensitization of the Highly HLA Sensitized Patient.

    Science.gov (United States)

    Jordan, S C; Choi, J; Kahwaji, J; Vo, A

    2016-04-01

    The presence of HLA antibodies remains a significant and often impenetrable barrier to kidney transplantation, leading to increased morbidity and mortality for patients remaining on long-term dialysis. In recent years, a number of new approaches have been developed to overcome these barriers. Intravenous immunoglobulin (IVIG) remains the lynchpin of HLA desensitization therapy and has been shown in a prospective, randomized, placebo-controlled trial to improve transplantation rates. In addition, IVIG used in low doses with plasma exchange is a reliable protocol for desensitization. Another significant advancement was the addition of rituximab (anti-B-cell therapy) to IVIG and plasma exchange-based desensitization. This approach has significantly improved rates of transplantation and outcomes. There is limited experience with bortezomib (anti-plasma cell therapy) and eculizumab (complement inhibition) for desensitization. However, recent data from a completed trial of eculizumab failed to show a significant benefit for prevention of antibody-mediated rejection compared with standard therapy plus placebo, and bortezomib produced inconsistent results. There is a growing interest in developing new therapeutic agents for desensitization. Newer approaches that address antibody reduction with B-cell depletion are discussed. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Analysis of mesiodistal angulations of preadjusted brackets

    Directory of Open Access Journals (Sweden)

    Marcos Rogério de MENDONÇA

    2014-08-01

    Full Text Available Manufacturers offer various prescriptions of preadjusted brackets for use in the “straight-wire” orthodontic technique. However, the need to incorporate bends in the rectangular wires during orthodontic finishing has led to concerns regarding the type of prescription chosen and the credibility of information provided by the manufacturer. The aim of this study was to compare the slot angulations of Roth prescription preadjusted metallic brackets for the maxillary left central incisor and maxillary left canine. For each tooth type, 10 brackets of three commercial brands (GAC, Forestadent and Morelli were selected. Two individual metal matrices for brackets and tooth positioning were made for each group of teeth. Captured images were obtained by standardized ortho-radial photography with a digital camera. Images were exported and analyzed with the Image J software package. One-way ANOVA and Tukey statistical analyses were performed at the 5% significance level. For brackets of the maxillary left central incisor, differences in mean angulation were observed between the Morelli and GAC groups (p < 0.01 and between the Forestadent and GAC groups (p < 0.01. For brackets of the maxillary left canine, differences in mean angulation were found between the Morelli and GAC groups (p < 0.01 and between the Morelli and Forestadent groups (p < 0.05. In conclusion, despite their same prescription name, the different brands exhibited significantly different angulation measurements.

  16. Design of an Orthodontic Torque Simulator for Measurement of Bracket Deformation

    Science.gov (United States)

    Melenka, G. W.; Nobes, D. S.; Major, P. W.; Carey, J. P.

    2013-12-01

    The design and testing of an orthodontic torque simulator that reproduces the effect of archwire rotation on orthodontic brackets is described. This unique device is capable of simultaneously measuring the deformation and loads applied to an orthodontic bracket due to archwire rotation. Archwire rotation is used by orthodontists to correct the inclination of teeth within the mouth. This orthodontic torque simulator will provide knowledge of the deformation and loads applied to orthodontic bracket that will aide clinicians by describing the effect of archwire rotation on brackets. This will also impact that design on new archwirebracket systems by providing an assessment of performance. Deformation of the orthodontic bracket tie wings is measured using a digital image correlation process to measure elastic and plastic deformation. The magnitude of force and moments applied to the bracket though the archwire is also measured using a six-axis load cell. Initial tests have been performed on two orthodontic brackets of varying geometry to demonstrate the measurement capability of the orthodontic torque simulator. The demonstration experiment shows that a Damon Q bracket had a final plastic deformation after a single loading of 0.022 mm while the Speed bracket deformed 0.071 mm. This indicates that the Speed bracket plastically deforms 3.2 times more than the Damon Q bracket for similar magnitude of applied moment. The demonstration experiment demonstrates that bracket geometry affect the deformation of orthodontic brackets and this difference can be detected using the orthodontic torque simulator.

  17. DESENSITIZATION PROPERTIES OF P2X3 RECEPTORS SHAPING PAIN SIGNALLING

    Directory of Open Access Journals (Sweden)

    Rashid eGiniatullin

    2013-12-01

    Full Text Available ATP-gated P2X3 receptors are mostly expressed by nociceptive sensory neurons and participate in transduction of pain signals. P2X3 receptors show a combination of fast desensitization onset and slow recovery. Moreover, even low nanomolar agonist concentrations unable to evoke a response, can induce desensitization via a phenomenon called ‘high affinity desensitization’. We have also observed that recovery from desensitization is agonist-specific and can range from seconds to minutes. The recovery process displays unusually high temperature dependence. Likewise, recycling of P2X3 receptors in peri-membrane regions shows unexpectedly large temperature sensitivity. By applying kinetic modeling, we have previously shown that desensitization characteristics of P2X3 receptor are best explained with a cyclic model of receptor operation involving three agonist molecules binding a single receptor and that desensitization is primarily developing from the open receptor state. Mutagenesis experiments suggested that desensitization depends on a certain conformation of the ATP binding pocket and on the structure of the transmembrane domains forming the ion pore. Further molecular determinants of desensitization have been identified by mutating the intracellular N- and C-termini of P2X3 receptor. Unlike other P2X receptors, the P2X3 subtype is facilitated by extracellular calcium that acts via specific sites in the ectodomain neighboring the ATP binding pocket. Thus, substitution of serine275 in this region (called ‘left flipper’ converts the natural facilitation induced by extracellular calcium to receptor inhibition. Given such their strategic location in nociceptive neurons and unique desensitization properties, P2X3 receptors represent an attractive target for development of new analgesic drugs via promotion of desensitization aimed at suppressing chronic pain.

  18. Frictional and mechanical properties of diamond-like carbon-coated orthodontic brackets.

    Science.gov (United States)

    Muguruma, Takeshi; Iijima, Masahiro; Brantley, William A; Nakagaki, Susumu; Endo, Kazuhiko; Mizoguchi, Itaru

    2013-04-01

    This study investigated the effects of a diamond-like carbon (DLC) coating on frictional and mechanical properties of orthodontic brackets. DLC films were deposited on stainless steel brackets using the plasma-based ion implantation/deposition (PBIID) method under two different atmospheric conditions. As-received metal brackets served as the control. Two sizes of stainless steel archwires, 0.018 inch diameter and 0.017 × 0.025 inch cross-section dimensions, were used for measuring static and kinetic friction by drawing the archwires through the bracket slots, using a mechanical testing machine (n = 10). The DLC-coated brackets were observed with a scanning electron microscope (SEM). Values of hardness and elastic modulus were obtained by nanoindentation testing (n = 10). Friction forces were compared by one-way analysis of variance and the Scheffé test. The hardness and elastic modulus of the brackets were compared using Kruskal-Wallis and Mann-Whitney U-tests. SEM photomicrographs showed DLC layers on the bracket surfaces with thickness of approximately 5-7 μm. DLC-coated brackets deposited under condition 2 showed significantly less static frictional force for the stainless steel wire with 0.017 × 0.025 inch cross-section dimensions than as-received brackets and DLC-coated brackets deposited under condition 1, although both DLC-coated brackets showed significantly less kinetic frictional force than as-received brackets. The hardness of the DLC layers was much higher than that of the as-received bracket surfaces. In conclusion, the surfaces of metal brackets can be successfully modified by the PBIID method to create a DLC layer, and the DLC-coating process significantly reduces frictional forces.

  19. Shear Bond Strength of Orthodontic Brackets Bonded to Zirconium Crowns.

    Science.gov (United States)

    Mehmeti, Blerim; Azizi, Bleron; Kelmendi, Jeta; Iljazi-Shahiqi, Donika; Alar, Željko; Anić-Milošević, Sandra

    2017-06-01

    An increasing demand for esthetic restorations has resulted in an increased use of all-ceramic restorations, such as zirconium. However, one of the challenges the orthodontist must be willing to face is how to increase bond strength between the brackets and various ceramic restorations.Bond strength can beaffected bybracket type, by the material that bracketsaremade of, and their base surface design or retention mode. ​: A im: of this study was to perform a comparative analysis of the shear bond strength (SBS) of metallic and ceramic orthodontic brackets bonded to all-zirconium ceramic surfaces used for prosthetic restorations, and also to evaluate the fracture mode of these two types of orthodontic brackets. Twenty samples/semi-crowns of all-zirconium ceramic, on which orthodontic brackets were bonded, 10 metallic and 10 ceramic polycrystalline brackets, were prepared for this research. SBS has been testedby Universal Testing Machine, with a load applied using a knife edged rod moving at a fixed rate of 1 mm/min, until failure occurred. The force required to debond the brackets was recorded in Newton, then SBS was calculated to MPa. In addition, the samples were analyzed using a digital camera magnifier to determine Adhesive Remnant Index (ARI). Statistical data were processed using t-test, and the level of significance was set at α = 0.05. Higher shear bond strength values were observed in metallic brackets bonded to zirconium crowns compared tothoseof ceramic brackets, with a significant difference. During the test, two of the ceramic brackets were partially or totally damaged. Metallic brackets, compared to ceramic polycrystalline brackets, seemed tocreate stronger adhesion with all-zirconium surfaces due to their better retention mode. Also, ceramic brackets showed higher fragility during debonding.

  20. Biodegradation of orthodontic metallic brackets and associated implications for friction.

    Science.gov (United States)

    Regis, Saulo; Soares, Paulo; Camargo, Elisa S; Guariza Filho, Odilon; Tanaka, Orlando; Maruo, Hiroshi

    2011-10-01

    This study aimed to assess the effect of clinical exposure on the surface morphology, dimensions, and frictional behavior of metallic orthodontic brackets. Ninety-five brackets, of 3 commercial brands, were retrieved from patients who had finished orthodontic treatment. As-received brackets, matched by type and brand, were used for comparisons. Surface morphology and precipitated material were analyzed by optical and scanning electron microscopy and x-ray microanalysis. Bracket dimensions were measured with a measuring microscope. Resistance to sliding on a stainless steel wire was assessed. Retrieved brackets showed surface alterations from corrosion, wear, and plastic deformation, especially in the external slot edges. Film deposition over the alloy surface was observed to a variable extent. The main elements in the film were carbon, oxygen, calcium, and phosphorus. The as-received brackets showed differences (P brackets' slots. The frictional behavior differed among brands. Retrieved brackets of 2 brands showed 10% to 20% increases in resistance to sliding. Metallic brackets undergo significant degradation during orthodontic treatment, possibly with increased friction. At present, it is difficult to predict the impact of these changes on the clinical performance of orthodontic components. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  1. Topological optimization of opening fence brackets on ring-stiffened cylindrical shell

    Directory of Open Access Journals (Sweden)

    SONG Xiaofei

    2018-02-01

    Full Text Available [Objectives] Stress concentration is prone to take place at connections between the opening fence and ring ribs of a ring-stiffened cylindrical shell under external pressure. [Methods] In this paper, a topological optimization method for the brackets that connect the fence to the ring ribs is proposed in order to effectively reduce the local high stress in the brackets. The sub-model technique is used to analyze the stress of the connecting brackets. In the design, the connection brackets are used as design variables and the stress of the shell, fence and ribs are used as constraints. The maximum stress of the bracket is minimized as the objective function. The topology optimization results are engineered to obtain the final form of the brackets. [Results] The calculation results show that brackets of which the panel is partially widened can effectively reduce the stress concentration position of the opening fence transverse offset if the side of the bracket away from the longitudinal section is longer; the opening fence is offset relative to the brackets, and the symmetrical design of the brackets is feasible. [Conclusions] This research provides a reference for similar structural design.

  2. Transfer, Behavioral Improvement, and Anxiety Reduction in Systematic Desensitization

    Science.gov (United States)

    Kennedy, Thomas D.; Kimura, Harry K.

    1974-01-01

    Degree of transfer and fear change associated with four levels of desensitization, pseudodesensitization, and no treatment were assessed in snakephobic students. Desensitization subjects reported significantly less anxiety than no-treatment controls when repeating their highest pretreatment responses, but were no different from either control…

  3. Therapist Warmth: Necessary or Sufficient Condition in Behavioral Desensitization?

    Science.gov (United States)

    Wolowitz, Howard Martin

    1975-01-01

    Discusses the Morris and Suckerman report on experimental studies testing the Rogerian hypothesis that phobic desensitization occurs as a function of therapist warmth versus the behavioral explanation that desensitization is a function of reciprocal inhibition. Morris and Suckerman respond to the critique. (Author/EJT)

  4. Effects of Modeling and Desensitation in Reducing Dentist Phobia

    Science.gov (United States)

    Shaw, David W.; Thoresen, Carl E.

    1974-01-01

    Many persons avoid dentists and dental work. The present study explored the effects of systematic desensitization and social-modeling treatments with placebo and assessment control groups. Modeling was more effective than desensitization as shown by the number of subjects who went to a dentist. (Author)

  5. Safety of aspirin desensitization in patients with reported aspirin allergy and cardiovascular disease.

    Science.gov (United States)

    McMullan, Kathryn L; Wedner, H James

    2013-01-01

    Aspirin (ASA) is the drug of choice in patients with coronary artery disease for primary and secondary prevention. This poses a problem for those patients reporting hypersensitivity to this drug or class of drugs. Desensitization to ASA may be carried out safely and effectively in patients with reported ASA or nonsteroidal anti-inflammatory drug (NSAID) hypersensitivity needing ASA for cardiac indications. Our 7-step protocol is one choice for a rapid desensitization protocol. A retrospective chart review was conducted evaluating ASA desensitization in patients with reported ASA or NSAID hypersensitivity and a cardiac indication for ASA. In 160 evaluations over 15 years, 89 desensitizations were performed in both the inpatient and outpatient setting with only 16 reactions (18%). Eleven of these 16 patients (68.7%) were able to take daily ASA. Twenty-six desensitization procedures were performed with our 7-step rapid desensitization protocol in 10 inpatients and 16 outpatients with 3 reactions (18.75% of reactions). Initial reaction to ASA involving angioedema and reacting to ASA within the past year increased the risk of having a reaction to desensitization. Desensitization may be safely performed in patients with reported ASA or NSAID hypersensitivity and a cardiac indication for ASA. Our 7-step rapid protocol may be used in both the inpatient and outpatient setting to desensitize these patients. Patients who had angioedema with ASA ingestion or a reaction to ASA within the past year are at higher risk for reaction during the desensitization protocol. The authors have no funding, financial relationships, or conflicts of interest to disclose. © 2012 Wiley Periodicals, Inc.

  6. Evaluation of the Friction of Self-Ligating and Conventional Bracket Systems

    Science.gov (United States)

    Tecco, Simona; Di Iorio, Donato; Nucera, Riccardo; Di Bisceglie, Beatrice; Cordasco, Giancarlo; Festa, Felice

    2011-01-01

    Objectives: This in vitro study evaluated the friction (F) generated by aligned stainless steel (SS) conventional brackets, self-ligating Damon MX© brackets (SDS Ormco, Glendora, California, USA), Time3© brackets (American Orthodontics, Sheboygan, Wisconsin, USA), Vision LP© brackets (American Orthodontics), and low-friction Slide© ligatures (Leone, Firenze, Italy) coupled with various SS, nickel-titanium (NiTi), and beta-titanium (TMA) archwires. Methods: All brackets had a 0.022-inch slot, and the orthodontic archwires were 0.014-inch, 0.016-inch, 0.014×0.025-inch, 0.018×0.025-inch, and 0.019×0.025-inch NiTi; 0.017×0.025-inch TMA; and 0.019×0.025-inch SS. Each bracket-archwire combination was tested 10 times. In the test, 10 brackets of the same group were mounted in alignment on a metal bar. The archwires moved through all the 10 brackets at a crosshead speed of 0.5 mm/min (each run lasted approximately 5 min). The differences among 5 groups of brackets were analyzed through the Kruskal-Wallis test, and a Mann-Whitney test was calculated as post hoc analysis. The P value was set at 0.05. Results: Coupled with 0.014-inch NiTi and 0.016-inch NiTi, Victory Series© brackets generated the greatest F, while Damon MX© and Vision LP© brackets generated the lowest (Pbrackets and Slide© ligatures. Coupled with all the rectangular archwires, Victory Series© brackets, Slide© ligatures, and Vision LP© self-ligating brackets generated significantly lower F than did Time3© and Damon MX© self-ligating brackets (Pbrackets are a family of brackets that, in vitro, can generate different levels of F when coupled with thin or thick, rectangular, or round archwires. Clinical conclusions based on our results are not possible due to the limitations of the experimental conditions. PMID:21769273

  7. Longitudinal tibial epiphyseal bracket in Nievergelt syndrome

    International Nuclear Information System (INIS)

    Burnstein, M.I.; De Smet, A.A.; Breed, A.L.; Thomas, J.R.; Hafez, G.R.

    1989-01-01

    A patient is described with lower extremity mesomelic dwarfism associated with bilateral congenital elbow, hip, and knee dislocations. Rhomboid-shaped tibiae and delayed ossification of the primary fibular ossification centers were demonstrated at birth. Plain films and magnetic resonance imaging revealed that the tibial deformities were due to the presence of longitudinal epiphyseal brackets. These brackets were observed at surgery and confirmed histologically. Recognition of the longitudinal epiphyseal bracket and its relationship to the tibial deformities seen in this patient with Nievergelt syndrome is important for planning surgical treatment. (orig.)

  8. Longitudinal tibial epiphyseal bracket in Nievergelt syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Burnstein, M.I.; De Smet, A.A.; Breed, A.L.; Thomas, J.R.; Hafez, G.R.

    1989-04-01

    A patient is described with lower extremity mesomelic dwarfism associated with bilateral congenital elbow, hip, and knee dislocations. Rhomboid-shaped tibiae and delayed ossification of the primary fibular ossification centers were demonstrated at birth. Plain films and magnetic resonance imaging revealed that the tibial deformities were due to the presence of longitudinal epiphyseal brackets. These brackets were observed at surgery and confirmed histologically. Recognition of the longitudinal epiphyseal bracket and its relationship to the tibial deformities seen in this patient with Nievergelt syndrome is important for planning surgical treatment. (orig.).

  9. Further validation of bracket pillar design methodology

    CSIR Research Space (South Africa)

    Vieira, F

    1998-07-01

    Full Text Available Design charts for bracket pillar design were developed under a previous SIMRAC project GAP 223 to provide rock mechanics engineers with an initial estimate of bracket pillar sizes for clearly identified geological discontinuities, based on mining...

  10. Cytokine expression before and after aspirin desensitization therapy in aspirin-exacerbated respiratory disease.

    Science.gov (United States)

    Aktas, Ayse; Kurt, Emel; Gulbas, Zafer

    2013-12-01

    Aspirin exacerbated respiratory disease (AERD) is induced by acetylsalicylic acid (ASA) and/or nonsteroidal antiinflammatory drugs (NSAIDs). Effects of desensitization on many mediators have been examined previously, but few studies addressed the influence of desensitization on T lymphocytes and T lymphocyte-derived cytokines. This study was performed to examine peripheral blood lymphocyte (PBL) cytokine expression in aspirin-sensitive patients who have asthma before and after aspirin desensitization. In this study, the release of interleukin-2 (IL-2), interleukin-4 (IL-4), and interferon-gamma (IFN-γ) by CD4+ T lymphocytes prior to aspirin desensitization were also measured at intracellular levels, and expression of these cytokines after 1 month aspirin desensitization was evaluated. Twelve patients with AERD were included in the study. Two different control groups were formed, one consisted of 15 healthy people and second 12 aspirin tolerant asthmatic (ATA) patients using aspirin. A blood sample was collected prior to desensitization, and the tests were repeated by taking a second blood sample 1 month after the 4-day desensitization treatment. The proportion of lymphocytes secreting IFN-γ in the study group was 15.61 ± 4.40 % before desensitization and 15.08 ± 5.89 % after desensitization. The rate of IFN-γ secreting CD4+ T lymphocytes was 20.51 ± 4.41 % in the normal control group and 16.07 ± 5.7 % in the ATA group (p = 0.021). The ratio of CD4+ T lymphocyte secreting IFN-γ was reduced in patients with AERD before desensitization compared to normal control group (p = 0.040). The levels of IL-2, IL-4, and the subsets of lymphocyte were not different before and after desensitization compared to control groups.

  11. [Precision of three-dimensional printed brackets].

    Science.gov (United States)

    Zhang, D; Wang, L C; Zhou, Y H; Liu, X M; Li, J

    2017-08-18

    This study was based on digital orthodontic diagnosis work flow for indirect bonding transfer tray model design and three-dimensional (3D) printing, and the aim of this paper was to inspect the dimensional accuracyof 3D printed brackets, which is the foundation of the follow up work and hoped that will illuminate the clinical application of the digital orthodontics work flow. The samples which consisted of 14 cases of patients with malocclusion from Department of Orthodontics Peking University were selected, including 8 cases with tooth extraction and 6 cases without tooth extraction. All the 14 patients were taken intra-oral scan (Trios 3Shape, Denmark) and cone-beam computed tomography (CBCT, NewTom 3G volumetric scanner, Aperio Service,Italy)shooting after periodontal treatment. STL data and DICOM data were obtained from intraoral scans and CBCT images.Data segmentation, registration, fusion, automatic tooth arrangement, virtual positioning of orthodontic appliance and conversion the coordinates of malocclusion model were all done with self-programming software. The data of 3D printing model with brackets on it were output finally and printed out with EDEN260V (Objet Geometries, Israel) to make indirect bonding transfer tray. Digital vernier caliper was used to measure the length and width of upper and lower left brackets and buccal tubes on those 3D models after removal of surrounding supporting material by ultrasonic vibration and water-spray. Intra-examiner reliability was assessed by using intra-class correlation coefficients (ICC), and one-sample T test was used to compare the measurements with the standard dimensional data of the brackets. There were significant differences which range in 0.04-0.17 mm between the 13 items out of the 19 measurement items. Except for the length of the lower left premolars'brackets, mean values of the other items were greater than the test value. Although the measurement results in the width of brackets and the width and

  12. Linezolid desensitization for a patient with multiple medication hypersensitivity reactions.

    Science.gov (United States)

    Bagwell, Autumn D; Stollings, Joanna L; White, Katie D; Fadugba, Olajumoke O; Choi, Jane J

    2013-01-01

    To describe a case in which a linezolid desensitization protocol was successfully used for a polymicrobial surgical wound infection in a patient with multiple drug hypersensitivity reactions. A 24-year-old woman with vocal cord dysfunction requiring tracheostomy was admitted for a surgical wound infection following a tracheostomy fistula closure procedure. The patient reported multiple antibiotic allergies including penicillins (rash), sulfonamides (rash), vancomycin (anaphylaxis), azithromycin (rash), cephalosporins (anaphylaxis), levofloxacin (unspecified), clindamycin (unspecified), and carbapenems (unspecified). Gram stain of the purulent wound drainage demonstrated mixed gram-negative and gram-positive flora, and bacterial cultures were overgrown with Proteus mirabilis, which precluded identification of other pathogens. Following failed test doses of linezolid, tigecycline, and daptomycin, all of which resulted in hypersensitivity reactions, a 16-step linezolid desensitization protocol was developed and successfully implemented without adverse reactions. The patient completed a 2-week course of antibiotic therapy that included linezolid upon finishing the desensitization protocol. Linezolid is useful in treating complicated and uncomplicated skin and soft tissue infections caused by gram-positive bacteria. With precautions, including premedication, a monitored nursing unit, and immediate availability of an emergency anaphylaxis kit, drug desensitization allows patients the ability to safely use medications to which they may have an immediate hypersensitivity reaction. Minimal data exist on linezolid desensitization protocols. Linezolid desensitization can be a viable option in patients requiring antimicrobial therapy for complicated gram-positive skin infections.

  13. Motivational Goal Bracketing: An Experiment

    DEFF Research Database (Denmark)

    Koch, Alexander; Nafziger, Julia

    We study in an online, real-effort experiment how the bracketing of non-binding goals affects performance in a work-leisure self-control problem. We externally induce the goal bracket - daily goals or a weekly goal - and within that bracket let subjects set goals for how much they want to work over...... a one-week period. Our theoretical model predicts (i) that weekly goals create incentives to compensate for a lower than desired performance today with the promise to work harder tomorrow, whereas daily goals exclude such excuses; (ii) that subjects with daily goals set higher goals in aggregate...... and work harder than those with weekly goals. Our data support these predictions. Surprisingly, however, when goals are combined with an externally enforced commitment that requires subjects to spend less than a minute each day on the task to get started working, performance deteriorates because of high...

  14. Galvanic Skin Response and Reported Anxiety During Systematic Desensitization

    Science.gov (United States)

    Hyman, Edward T.; Gale, Elliot N.

    1973-01-01

    The purpose of the present study was to investigate the GSR during systematic desensitization. Three groups of females each were preselected for high snake fear. Outcome measures indicated that the desensitization group reduced phobic behavior most, followed by the relaxation group, and then the exposure groups. (Author)

  15. Semantics Desensitization: A Paradigmatic Intervention Approach to Anxiety Disorders.

    Science.gov (United States)

    Hekmat, Hamid; And Others

    1984-01-01

    Assigned speech-anxious clients (N=30) to one of the following treatment conditions: (1) semantic desensitization; (2) attention placebo and (3) waiting list control. Results indicated that semantic desensitization therapy reduced both the affective and behavioral components of anxiety as compared to the two controls. (LLL)

  16. [Adaptive desensitization for acetylsalicylic acid hypersensitivity: A success story?].

    Science.gov (United States)

    Mühlmeier, G; Hausch, R; Maier, H

    2015-10-01

    Adaptive desensitization still remains the only causative therapy for acetylsalicylic acid (ASA) hypersensitivity and is carried out nearly worldwide. To date there are hardly any data available on disease development under current desensitization therapy and longitudinal data in particular are missing. Out of a large collective of patients with proven hypersensitivity to ASA, 194 patients with initiated desensitization treatment were observed for periods up to 5 years (average 32 months). Patients with immediate reactions to systemic challenge tests revealed a response rate of 77% after 12 months of therapy. In this period 12% reached complete remission, 38% showed a clear reduction in symptoms, 32% reached partial remission, 13% remained unchanged and 5% suffered from disease progression. Adaptive desensitization therapy for hypersensitivity to ASA has been shown to be an effective causative therapy and chronic hyperplastic sinusitis as well as bronchial asthma could be improved. For the determination of maintenance dosages and required time periods more data are needed.

  17. [Castleman's disease: Rapid desensitization for hypersensitivity reaction to rituximab].

    Science.gov (United States)

    Boin, C; Lambert, S; Thomann, P; Aujoulat, O; Kieffer, P

    2016-06-01

    Rapid desensitization allows secure administration of a drug and is indicated when there is no therapeutic alternative. We report a 49-year-old patient who presented with a hypersensitivity reaction following an infusion of rituximab (375mg/m(2)) in the context of a Castleman's syndrome. After a clinical flare (splenomegaly, adenopathies) despite treatment with tocilizumab, anakinra and valganciclovir, the reintroduction of rituximab was decided, according to the rapid desensitization protocol. Four full dose desensitizations were successfully performed allowing immediate clinical improvement (apyrexia, loss of sweating and lymphadenopathy, splenomegaly partial regression) and biological (negativation of HHV8 viral load, and disappearance of neutropenia, anemia and thrombocytopenia). Rapid desensitization is a promising method for the pursuit of rituximab therapy after a hypersensitivity reaction and should be considered in patients with no acceptable therapeutic alternative. Copyright © 2015 Société Nationale Française de Médecine Interne (SNFMI). Published by Elsevier SAS. All rights reserved.

  18. Enhancement of acetylcholine-induced desensitization of guinea-pig ileal longitudinal muscle in Ca2+-free conditions.

    Science.gov (United States)

    Horio, S; Nagare, T; Moritoki, H

    1999-10-01

    1. To determine the role of cellular Ca2+ in desensitization, acetylcholine(ACh)-induced desensitization was studied under Ca2+-free condition in guinea-pig ileal longitudinal muscle. 2. Pretreatment of the tissue with 10(-4) M ACh (desensitizing treatment) in normal Tyrode solution caused desensitization of the responses both to ACh and histamine. The desensitizing treatment performed in Ca2+-free solution enhanced desensitization of the responses to ACh and histamine significantly. 3. The desensitizing treatment with ACh caused suppression of the responses to high K+ (tonic component) and Bay K 8644. The desensitizing treatment performed in Ca2+-free solution potentiated the suppression of the responses to high K+ and Bay K 8644 significantly. 4. ACh-induced desensitization was enhanced significantly in the presence of a protein kinase C inhibitor, 1-(5-isoquinolinesulfonyl)-2-methylpiperazine(H-7, 10(-4) M) to a similar extent as desensitization obtained under Ca2+-free condition, but not in the presence of a non-specific and less potent kinase inhibitor, N-(2-guanidinoethyl)-5-isoquinolinesulfonamide hydrochloride (HA1004, 10(-4) M). 5. These results suggested that voltage-gated Ca2+ channels were involved in ACh-induced desensitization and that intracellular Ca2+, which was increased during the stimulation with ACh, inhibited desensitization through the activation of protein kinase C. This kinase could have activated or protected Ca2+ channels during the desensitization process to reduce desensitization.

  19. Uncoupling of the beta-adrenergic receptor as a mechanism of in vitro neutrophil desensitization

    International Nuclear Information System (INIS)

    Galant, S.P.; Britt, S.

    1984-01-01

    Human leukocytes have been useful in studying desensitization phenomena to beta-adrenergic agonists in a number of clinical conditions. In the present in vitro study the authors have explored the mechanism for beta-adrenergic desensitization and have compared conditions for homologous and heterologous desensitization, using the intact PMN model. PMN preincubated with isoproterenol (10 -4 M), washed thoroughly, then restimulated, desensitized rapidly so that within 10 min 80% of control isoproterenol-induced cyclic AMP stimulation is lost. Cells washed free of isoproterenol recover full responsiveness in 1 to 2 hr. The estimated isoproterenol desensitization EC 50 in cells washed and then restimulated is 1 x 10 -5 M, and EC 50 in unwashed cells that are restimulated is 9 x 10 -8 M. Rank-order potency studies of catecholamine desensitization show isoproterenol > epinephrine > norepinephrine, a beta-2 pattern. Isoproterenol-induced desensitization results in a small reduction in [ 3 H]DHA binding sites, which becomes statistically significant (p 50 of 6.6 +/- 2.6 x 10 - (M, which is significantly different (p 50 of 38.1 +/- 9.1 x 10 -1 M found when cells are previously desensitized with isoproterenol for 10 min. GTP does not affect the EC 50 of desensitized cells. Finally, prolonged (3 hr) isoproterenol preincubation results in a small but significant (p 1 (59.3% +/- 7.4), suggesting heterologous desensitization. These studies suggest that the human PMN is a suitable model to study both homologous and heterologous desensitization in vitro. 22 references. 6 figures. 3 tables

  20. The role of aspirin desensitization in patients with aspirin-exacerbated respiratory disease (AERD).

    Science.gov (United States)

    Spies, Jonas Willian; Valera, Fabiana Cardoso Pereira; Cordeiro, Daniel Loiola; de Mendonça, Taís Nociti; Leite, Marcelo Gonçalves Junqueira; Tamashiro, Edwin; Arruda, Luiza Karla; Anselmo-Lima, Wilma Terezinha

    2016-01-01

    Aspirin-exacerbated respiratory disease (AERD) consists of a classic tetrad: moderate/severe asthma, chronic rhinosinusitis, nasal polyps, and intolerance to aspirin or other nonsteroidal anti-inflammatory drugs. Clinical control with drugs, surgery, and desensitization are treatment options. To evaluate the efficacy and tolerability of aspirin desensitization in patients with AERD. Periodic symptom assessment and endoscopy in patients with AERD undergoing surgery who were desensitized. Seventeen patients were desensitized. Eight patients completed the desensitization and were followed for a minimum of a one-year period (mean 3.1 years). These patients showed improvement in all symptoms. Moreover, surgical reassessment was not indicated in any of these patients and there was a decrease in costs with medication and procedures. Eight patients did not complete desensitization, mainly due to procedure intolerance and uncontrolled asthma, whereas another patient was lost to follow-up. Aspirin desensitization, when tolerated, was effective in patients with AERD and with poor clinical/surgical response. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  1. Effect of desensitizing agents on dentin permeability.

    Science.gov (United States)

    Ishihata, Hiroshi; Kanehira, Masafumi; Nagai, Tomoko; Finger, Werner J; Shimauchi, Hidetoshi; Komatsu, Masashi

    2009-06-01

    To investigate the in vitro efficacy of two dentin desensitizing products at reducing liquid permeability through human dentin discs. The tested hypothesis was that the products, in spite of different chemical mechanisms were not different at reducing or eliminating flow through dentin discs. Dentin slices (1 mm thick) were prepared from 16 extracted human third molars and their permeability was indirectly recorded in a split chamber model, using a chemiluminescence technique, after EDTA treatment (control), after soaking with albumin, and after desensitizer application. Two products were studied: MS Coat, a self-curing resin-containing oxalate product, and Gluma Desensitizer, a glutaraldehyde/HEMA-based agent without initiator. The dentin slices were mounted between an upper chamber, filled with an aqueous solution of 1% potassium ferricyanide and 0.3% hydrogen peroxide, and a lower chamber filled with 1% sodium hydroxide solution and 0.02% luminol. The upper solution was pressurized, and upon contact with the luminol solution a photochemical signal was generated and recorded as a measure of permeability throughout two consecutive pressurizing cycles at 2.5 and 13 kPa (26 and 133 cm H2O), respectively. The permeability of the control and albumin-soaked samples was similarly high. After application of the desensitizing agents, dentin permeability was reduced to virtually zero at both pressure levels (P < 0.001).

  2. Friction behavior of ceramic injection-molded (CIM) brackets.

    Science.gov (United States)

    Reimann, Susanne; Bourauel, Christoph; Weber, Anna; Dirk, Cornelius; Lietz, Thomas

    2016-07-01

    Bracket material, bracket design, archwire material, and ligature type are critical modifiers of friction behavior during archwire-guided movement of teeth. We designed this in vitro study to compare the friction losses of ceramic injection-molded (CIM) versus pressed-ceramic (PC) and metal injection-molded (MIM) brackets-used with different ligatures and archwires-during archwire-guided retraction of a canine. Nine bracket systems were compared, including five CIM (Clarity™ and Clarity™ ADVANCED, both by 3M Unitek; discovery(®) pearl by Dentaurum; Glam by Forestadent; InVu by TP Orthodontics), two PC (Inspire Ice by Ormco; Mystique by DENTSPLY GAC), and two MIM (discovery(®) and discovery(®) smart, both by Dentaurum) systems. All of these were combined with archwires made of either stainless steel or fiberglass-reinforced resin (remanium(®) ideal arch or Translucent pearl ideal arch, both by Dentaurum) and with elastic ligatures or uncoated or coated stainless steel (all by Dentaurum). Archwire-guided retraction of a canine was simulated with a force of 0.5 N in the orthodontic measurement and simulation system (OMSS). Friction loss was determined by subtracting the effective orthodontic forces from the applied forces. Based on five repeated measurements performed on five brackets each, weighted means were calculated and evaluated by analysis of variance and a Bonferroni post hoc test with a significance level of 0.05. Friction losses were significantly (p brackets used with a stainless-steel ligature and the resin archwire. No critical difference to friction behavior was apparent between the various manufacturing technologies behind the bracket systems.

  3. Evaluation of friction produced by self-ligating, conventional and Barbosa Versatile brackets

    Directory of Open Access Journals (Sweden)

    Jurandir Antonio BARBOSA

    Full Text Available Abstract Introduction The Barbosa Versatile bracket design may provide lower frictional force and greater sliding. However, no in vitro studies have shown its sliding mechanisms and frictional resistance, particularly in comparison with other self-ligating or conventional brackets. Objective To compare the frictional resistance among self-ligating brackets (EasyClip/ Aditek, Damon MX/ Ormco and In Ovation R/ GAC; conventional brackets (Balance Roth/ GAC, and Roth Monobloc/ Morelli; and Barbosa Versatile bracket (Barbosa Versatile/ GAC with different angles and arch wires. Material and method Brackets were tested with the 0.014", 0.018", 0.019"×0.025" and 0.021"×0.025" stainless steel wires, with 0, 5, 10, 15 and 20 degree angulations. Tying was performed with elastomeric ligature for conventional and Barbosa Versatile brackets, or with a built-in clip system of the self-ligating brackets. A universal testing machine was used to obtain sliding strength and friction value readouts between brackets and wires. Result Three-way factorial ANOVA 4×5×6 (brackets × angulation × wire and Tukey tests showed statistically significant differences for all factors and all interactions (p<0.0001. Static frictional resistance showed a lower rate for Barbosa Versatile bracket and higher rates for Roth Monobloc and Balance brackets. Conclusion The lowest frictional resistance was obtained with the Barbosa Versatile bracket and self-ligating brackets in comparison with the conventional type. Increasing the diameter of the wires increased the frictional resistance. Smaller angles produced less frictional resistance.

  4. Rapid polyclonal desensitization with antibodies to IgE and FcεRIα.

    Science.gov (United States)

    Khodoun, Marat V; Kucuk, Zeynep Yesim; Strait, Richard T; Krishnamurthy, Durga; Janek, Kevin; Lewkowich, Ian; Morris, Suzanne C; Finkelman, Fred D

    2013-06-01

    Rapid desensitization, a procedure in which persons allergic to an antigen are treated at short intervals with increasing doses of that antigen until they tolerate a large dose, is an effective, but risky, way to induce temporary tolerance. We wanted to determine whether this approach can be adapted to suppress all IgE-mediated allergies in mice by injecting serially increasing doses of monoclonal antibodies (mAbs) to IgE or FcεRIα. Active and passive models of antigen- and anti-IgE mAb-induced IgE-mediated anaphylaxis were used. Mice were desensitized with serially increasing doses of anti-IgE mAb, anti-FcεRIα mAb, or antigen. Development of shock (hypothermia), histamine and mast cell protease release, cytokine secretion, calcium flux, and changes in cell number and FcεRI and IgE expression were evaluated. Rapid desensitization with anti-IgE mAb suppressed IgE-mediated immediate hypersensitivity; however, some mice developed mild anaphylaxis during desensitization. Rapid desensitization with anti-FcεRIα mAb that only binds FcεRI that is not occupied by IgE suppressed both active and passive IgE-mediated anaphylaxis without inducing disease. It quickly, but temporarily, suppressed IgE-mediated anaphylaxis by decreasing mast cell signaling through FcεRI, then slowly induced longer lasting mast cell unresponsiveness by removing membrane FcεRI. Rapid desensitization with anti-FcεRIα mAb was safer and longer lasting than rapid desensitization with antigen. A rapid desensitization approach with anti-FcεRIα mAb safely desensitizes mice to IgE-mediated anaphylaxis by inducing mast cell anergy and later removing all mast cell IgE. Rapid desensitization with an anti-human FcεRIα mAb may be able to prevent human IgE-mediated anaphylaxis. Copyright © 2013 American Academy of Allergy, Asthma & Immunology. Published by Mosby, Inc. All rights reserved.

  5. Outpatient desensitization in selected patients with platinum hypersensitivity reactions.

    Science.gov (United States)

    O'Malley, David M; Vetter, Monica Hagan; Cohn, David E; Khan, Ambar; Hays, John L

    2017-06-01

    Platinum-based chemotherapies are a standard treatment for both initial and recurrent gynecologic cancers. Given this widespread use, it is important to be aware of the features of platinum hypersensitivity reactions and the subsequent treatment of these reactions. There is also increasing interest in the development of desensitization protocols to allow patients with a history of platinum hypersensitivity to receive further platinum based therapy. In this review, we describe the management of platinum hypersensitivity reactions and the desensitization protocols utilized at our institution. We also describe the clinical categorizations utilized to triage patients to appropriate desensitization protocols. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Omalizumab facilitates rapid oral desensitization for peanut allergy.

    Science.gov (United States)

    MacGinnitie, Andrew J; Rachid, Rima; Gragg, Hana; Little, Sara V; Lakin, Paul; Cianferoni, Antonella; Heimall, Jennifer; Makhija, Melanie; Robison, Rachel; Chinthrajah, R Sharon; Lee, John; Lebovidge, Jennifer; Dominguez, Tina; Rooney, Courtney; Lewis, Megan Ott; Koss, Jennifer; Burke-Roberts, Elizabeth; Chin, Kimberly; Logvinenko, Tanya; Pongracic, Jacqueline A; Umetsu, Dale T; Spergel, Jonathan; Nadeau, Kari C; Schneider, Lynda C

    2017-03-01

    Peanut oral immunotherapy is a promising approach to peanut allergy, but reactions are frequent, and some patients cannot be desensitized. The anti-IgE medication omalizumab (Xolair; Genentech, South San Francisco, Calif) might allow more rapid peanut updosing and decrease reactions. We sought to evaluate whether omalizumab facilitated rapid peanut desensitization in highly allergic patients. Thirty-seven subjects were randomized to omalizumab (n = 29) or placebo (n = 8). After 12 weeks of treatment, subjects underwent a rapid 1-day desensitization of up to 250 mg of peanut protein, followed by weekly increases up to 2000 mg. Omalizumab was then discontinued, and subjects continued on 2000 mg of peanut protein. Subjects underwent an open challenge to 4000 mg of peanut protein 12 weeks after stopping study drug. If tolerated, subjects continued on 4000 mg of peanut protein daily. The median peanut dose tolerated on the initial desensitization day was 250 mg for omalizumab-treated subjects versus 22.5 mg for placebo-treated subject. Subsequently, 23 (79%) of 29 subjects randomized to omalizumab tolerated 2000 mg of peanut protein 6 weeks after stopping omalizumab versus 1 (12%) of 8 receiving placebo (P omalizumab versus 1 subject receiving placebo passed the 4000-mg food challenge. Overall reaction rates were not significantly lower in omalizumab-treated versus placebo-treated subjects (odds ratio, 0.57; P = .15), although omalizumab-treated subjects were exposed to much higher peanut doses. Omalizumab allows subjects with peanut allergy to be rapidly desensitized over as little as 8 weeks of peanut oral immunotherapy. In the majority of subjects, this desensitization is sustained after omalizumab is discontinued. Additional studies will help clarify which patients would benefit most from this approach. Copyright © 2016 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  7. [Bond strengths of customized titanium brackets manufactured by selective laser melting].

    Science.gov (United States)

    Zou, Dao-xing; Wang, Ze-min; Guo, Hong-ming; Li, Song; Bai, Yu-xing

    2013-07-01

    To investigate the bond strengths of customized titanium bracket manufactured by selective laser melting. Eighty human premolars which had been extracted for orthodontic purpose were collected and divided randomly (by random table) into two groups (customized bracket group and 3M bracket group, 40 molars in each group). The 35% phosphoric acid was used for etching and the brackets were bonded with 3M Unitek bonding adhesive. All bonded specimens were placed in saline for 24 hours at room temperature and were tested on DWD3050 electronic testing machine to determine the shear bond strength and tensile bond strength. After debonding, the adhesive remnant indexes (ARI) were recorded. The shear bond strengths of customized brackets was 6.80 (6.20, 8.32) MPa, which was significantly lower than that of the 3M brackets [10.46 (9.72, 11.48) MPa] (Z = -3.463, P < 0.05). And the tensile bond strengths of customized brackets was (6.93 ± 1.21) MPa, which was significantly higher than that of the 3M brackets [(5.88 ± 1.23) MPa] (t = 2.81, P < 0.05). No significant difference was found in the ARI between two different kinds of the brackets. The shear bond strength and tensile bond strength of both kinds of brackets were enough for clinic application.

  8. Can 10% hydrofluoric acid be used for reconditioning of orthodontic brackets?

    Science.gov (United States)

    Pompeo, Daniela D; Rosário, Henrique D; Lopes, Beatriz Mv; Cesar, Paulo F; Paranhos, Luiz Renato

    2016-01-01

    Bracket debonding is a common problem during orthodontic treatment. This type of failure is associated to masticatory forces, poor adhesion, and the need for repositioning the piece. The objective of this work was to compare the shear bond strength of debonded brackets that were reconditioned using different protocols (alumina blasting versus hydrofluoric etching). This was an in vitro experimental study with 45 stainless steel orthodontic brackets. They were randomly divided into three groups: (1) New brackets (n = 15), (2) brackets reconditioned using 10% hydrofluoric acid for 60 s (n = 15), and (3) brackets reconditioned by aluminum oxide blasting until complete removal of the remaining resin (n = 15). In Groups 2 and 3, the insertion of composite resin proceeded in two stages to simulate a type of bracket failure in which the bonding resin was left at the bracket base. For the shear test, the assembly composed by the metallic support, and specimen was taken to the Instron universal testing machine in which the specimens were loaded using a semicircle-shaped active tip in the region of the bonding interface parallel to the surface of the bracket at a speed of 0.5 mm/min. The data were subjected to D'Agostino's normality test to have their distribution checked. Analysis of variance and Tukey's test (P brackets) showed higher bond strength than that obtained for the group treated with hydrofluoric acid (Group 2, P brackets. Nevertheless, the reconditioning technique using 10% fluoridric acid for 60 s was not efficient for clinical use.

  9. Wronski Brackets and the Ferris Wheel

    Science.gov (United States)

    Martin, Keye

    2005-11-01

    We connect the Bayesian order on classical states to a certain Lie algebra on C^infty[0,1]. This special Lie algebra structure, made precise by an idea we introduce called a Wronski bracket, suggests new phenomena the Bayesian order naturally models. We then study Wronski brackets on associative algebras, and in the commutative case, discover the beautiful result that they are equivalent to derivations.

  10. Aspirin desensitization in patients undergoing percutaneous coronary intervention: a survey of current practice.

    Science.gov (United States)

    Chapman, Andrew R; Rushworth, Gordon F; Leslie, Stephen J

    2013-01-01

    Aspirin remains the mainstay of anti-platelet therapy in cardiac patients. However, if a patient is allergic to aspirin and dual anti-platelet therapy is indicated - such as with percutaneous coronary intervention (PCI), then there is no clear guidance. One possibility is aspirin desensitization. A variety of protocols exist for the rapid desensitization of patients with aspirin allergy. The aim of this survey was to assess current knowledge and practice regarding aspirin desensitization in the UK. We conducted a UK wide survey of all UK 116 PCI centers and obtained complete responses from 40 (35.4%) centers. Of these, just 7 (17.5%) centers had previously desensitised patients; 29 (87.9%) centers suggested a lack of a local protocol prevented them from desensitizing, with 10 (30.3%) unsure of how to conduct desensitization. Only 5 (12.5%) centers had a local policy for aspirin desensitization although 25 (64.1%) units had a clinical strategy for dealing with aspirin allergy; the majority (72%) giving higher doses of thienopyridine class drugs. In the UK, there appears to be no consistent approach to patients with aspirin allergy. Patients undergoing PCI benefit from dual anti-platelet therapy (including aspirin), and aspirin desensitization in those with known allergy may facilitate this. Sustained effort should be placed on encouraging UK centers to use desensitization as a treatment modality prior to PCI rather than avoiding aspirin altogether.

  11. A practical and successful desensitization protocol for immediate hypersensitivity reactions to iron salts.

    Science.gov (United States)

    Demir, Semra; Olgac, Muge; Unal, Derya; Gelincik, Asli; Colakoglu, Bahauddin; Buyukozturk, Suna

    2014-01-01

    Orally administered iron salts (OAS) are widely used in the management of iron deficiency anemia and hypersensitivity reactions to OAS are not common. If an offending drug is the sole option or is significantly more effective than its alternatives, it can be readministered by desensitization. The oral desensitization protocols for iron published so far concern either desensitization that was completed only over a long period or did not attain the recommended therapeutic dose. We aimed to develop a more effective protocol. We report here on 2 patients who experienced hypersensitivity reactions to OAS. After confirming the diagnosis, both patients were desensitized to oral ferrous (II) glycine sulfate complex according to a 2-day desensitization protocol. A commercial suspension of oral ferrous glycine sulfate, which contains 4 mg of elemental iron in 1 ml, was preferred. We started with a dose as low as 0.1 ml from a 1/100 dilution (0.004 mg elemental iron) of the original suspension and reached the maximum effective dose in 2 days. Both patients were successfully desensitized and they went on to complete the 6-month iron treatment without any adverse effects. Although hypersensitvity reactions to iron are not common, there is no alternative for iron administration. Therefore, desensitization has to be the choice. This easy desensitization protocol seems to be a promising option. © 2014 S. Karger AG, Basel.

  12. Tool Releases Optical Elements From Spring Brackets

    Science.gov (United States)

    Gum, J. S.

    1984-01-01

    Threaded hooks retract bracket arms holding element. Tool uses three hooks with threaded shanks mounted in ring-shaped holder to pull on tabs to release optical element. One person can easily insert or remove optical element (such as prism or lens) from spring holder or bracket with minimal risk of damage.

  13. Evaluation of XHVRB for Capturing Explosive Shock Desensitization

    Science.gov (United States)

    Tuttle, Leah; Schmitt, Robert; Kittell, Dave; Harstad, Eric

    2017-06-01

    Explosive shock desensitization phenomena have been recognized for some time. It has been demonstrated that pressure-based reactive flow models do not adequately capture the basic nature of the explosive behavior. Historically, replacing the local pressure with a shock captured pressure has dramatically improved the numerical modeling approaches. Models based upon shock pressure or functions of entropy have recently been developed. A pseudo-entropy based formulation using the History Variable Reactive Burn model, as proposed by Starkenberg, was implemented into the Eulerian shock physics code CTH. Improvements in the shock capturing algorithm were made. The model is demonstrated to reproduce single shock behavior consistent with published pop plot data. It is also demonstrated to capture a desensitization effect based on available literature data, and to qualitatively capture dead zones from desensitization in 2D corner turning experiments. This models shows promise for use in modeling and simulation problems that are relevant to the desensitization phenomena. Issues are identified with the current implementation and future work is proposed for improving and expanding model capabilities. Sandia National Laboratories is a multi-mission laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. DOE's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  14. Pitocin and autism: An analysis of oxytocin receptor desensitization in the fetus.

    Science.gov (United States)

    Gottlieb, Mark M

    2016-02-01

    The risk of Pitocin as a cause of autism attributable to oxytocin receptor desensitization in the brain of the fetus is evaluated in terms of a mathematical model. A composite unit, D, for oxytocin receptor desensitization levels is established with the form ((IU-h)/ml)E-3, where IU is the international unit for oxytocin. The desensitization values for oxytocin receptor desensitization at a concentration of 10 nmol of oxytocin per liter for 3, 4.2 and 6h corresponding to 0%, 50% and 100% desensitization are calculated to be 15 D, 21 D, and 30 D, respectively. The permeability of the blood-brain barrier in the fetus to oxytocin is discussed, and the upper limit of the concentration of Pitocin in the placenta, and its possible diffusion into the blood and brain of the fetus, is calculated for a routine dose of 6 milli U per minute of Pitocin over a 12h labor. This dose of Pitocin is shown to result in a desensitization value in units of D that is more than a factor of 10 below the 0% desensitization value of 15 D. This indicates that routine doses of Pitocin are not a significant cause of autism attributable to oxytocin receptor desensitization. This is consistent with the findings of a major epidemiological study of the association of Pitocin with autism in Denmark entitled, "Oxytocin-augmented labor and risk for males", Behavioral Brain Research, May 1, 2015; 284:207-212, which found no association between the use of Pitocin during labor and the incidence of autism for females, and a modest association for males. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Drug desensitization in the management of hypersensitivity reactions to monoclonal antibodies and chemotherapy.

    Science.gov (United States)

    Mezzano, Veronica; Giavina-Bianchi, Pedro; Picard, Matthieu; Caiado, Joana; Castells, Mariana

    2014-04-01

    Hypersensitivity reactions to monoclonal antibodies and chemotherapy, which may vary in severity from mild to life-threatening, can lead to their discontinuation and replacement by alternative agents that are often less effective, more toxic, and/or more expensive. Drug desensitization has emerged as the best treatment modality capable of allowing re-introduction of the hypersensitivity reaction-inducing medication in highly sensitized patients in need of first line therapies. In recent years, the availability of new anti-neoplastic drugs and therapeutic monoclonal antibodies has increased, as has the potential for hypersensitivity reactions. Development of desensitization protocols for these new medications requires a careful assessment of the potential risks and benefits. The purposes of this review are to provide an overview of the presentation of hypersensitivity reactions amenable to desensitization and to increase awareness of the indications for and outcomes of desensitization protocols. Rapid drug desensitization has proven to be a safe and effective way of administering first line therapy to patients with hypersensitivity reactions, providing an extremely powerful treatment modality for patients for whom alternative drugs are deemed unacceptable. Rapid drug desensitization protocols should be administered only by highly trained allergists and nurses who have experience in determining which reactions are amenable to desensitization, and can identify high risk patients and provide them with appropriate care. Efforts should be made to increase awareness of the remarkable safety and efficacy of rapid drug desensitization among non-allergists, especially in the fields of oncology and rheumatology, so as to favor its universal application. Development of desensitization units to provide state-of-the-art care is possible only through coordinated teamwork.

  16. Effects of different black mediators on the shear strength of orthodontic bracket to the enamel treated with Nd-Yag laser

    Science.gov (United States)

    Huang, Shun-Te; Lin, I.-Shueng; Tsai, Chi-Cheng

    1995-04-01

    The Nd:YAG laser has ablation, crack, and crater effects on the dental enamel through black mediators which are very similar to the acid etching effects of phosphoric acid. This study was designed for searching how the different black mediators influence the shear strengths of the brackets bound to the enamel surfaces which were treated with the Nd:YAG laser. 90 bovine enamels divided into 5 groups were painted with 5 kinds of black mediators including Chinese ink, oil ink, black ball pen, water ink and black transfer paper. The enamel surfaces painted with black mediators were then radiated by Nd:YAG laser (ADL; American Dental Laser 300dl, power: 20 pps, 87.5 mj). Orthodontic brackets were bonded to the radiated surfaces. Then the shear strengths of the brackets to the enamels were measured by Instron. The results showed that the Chinese ink group and oil ink group has the strongest shear strength, ball pen group and water ink group showed the second strength, and the transfer paper group has the lowest shear strength. In addition, scanning electronic microscope also was used to observe the topographic changes of the enamel surfaces induced by the laser ablation.

  17. EMG Biofeedback Training Versus Systematic Desensitization for Test Anxiety Reduction

    Science.gov (United States)

    Romano, John L.; Cabianca, William A.

    1978-01-01

    Biofeedback training to reduce test anxiety among university students was investigated. Biofeedback training with systematic desensitization was compared to an automated systematic desensitization program not using EMG feedback. Biofeedback training is a useful technique for reducing test anxiety, but not necessarily more effective than systematic…

  18. Debris and friction of self-ligating and conventional orthodontic brackets after clinical use.

    Science.gov (United States)

    Araújo, Raíssa Costa; Bichara, Lívia Monteiro; Araujo, Adriana Monteiro de; Normando, David

    2015-07-01

    To compare the degree of debris and friction of conventional and self-ligating orthodontic brackets before and after clinical use. Two sets of three conventional and self-ligating brackets were bonded from the first molar to the first premolar in eight individuals, for a total of 16 sets per type of brackets. A passive segment of 0.019 × 0.025-inch stainless steel archwire was inserted into each group of brackets. Frictional force and debris level were evaluated as received and after 8 weeks of intraoral exposure. Two-way analysis of variance and Wilcoxon signed-rank test were applied at P brackets (P brackets showed a higher amount of debris compared with the conventional brackets. The frictional force in conventional brackets was significantly higher when compared with self-ligating brackets before clinical use (P brackets, when exposed to the intraoral environment, showed a significant increase in frictional force during the sliding mechanics. Debris accumulation was higher for the self-ligating system.

  19. Aplikasi eye moving desensitization dan reprocessing dalam konseling post-traumatic stress disorder

    Directory of Open Access Journals (Sweden)

    Hengki Satrianta

    2017-06-01

    Full Text Available Akhir-akhir ini banyak peristiwa yang berpotensi memunculkan efek traumatik yang jika tidak ditangani akan menimbulkan gangguan stres pascatrauma. Olehnya itu, dibutuhkan upaya-upaya untu menangani masalah ini. Salah satu upaya yang dimaksud adalah penggunaan eye moving desensitization and reprocessing. Artikel ini ditulis dengan fokus pada penanganan gangguan stres pascatrauma melalui eye moving desensitization and reprocessing. Tujuan penulisan artikel ini adalah untuk mengetahui gambaran umum pelaksanaan eye moving desensitization and reprocessing. Eye moving desensitization and reprocessing mampu menjadi salah satu teknik dalam penanganan gangguan stres pascatrauma. Oleh karena itu disarankan bagi praktisi konseling di Indonesia mampu menjadikan “terapi unik” ini sebagai teknik penanganan gangguan stres pascatrauma.

  20. 21 CFR 872.3750 - Bracket adhesive resin and tooth conditioner.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Bracket adhesive resin and tooth conditioner. 872... SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3750 Bracket adhesive resin and tooth conditioner. (a) Identification. A bracket adhesive resin and tooth conditioner is a device...

  1. Successful drug desensitization in patients with delayed-type allergic reactions to anti-tuberculosis drugs

    Directory of Open Access Journals (Sweden)

    Krittaecho Siripassorn

    2018-03-01

    Full Text Available Objective: To evaluate the outcomes of anti-tuberculosis drug desensitization. Methods: This was a retrospective study. Inclusion criteria were as follows: age >18 years, documented tuberculosis infection, a previous cutaneous allergic reaction to anti-tuberculosis drugs, and having undergone drug desensitization between January 2003 and March 2014. The definition of allergic reaction to anti-tuberculosis drugs included (1 a temporal relationship between drug use and the allergic reaction; (2 improvement in the allergic reaction after drug withdrawal; (3 recurrence of the allergic reaction after reintroduction of only the offending drug; and (4 absence of other causes. Results: A total of 19 desensitization procedures were performed. The drugs used for these procedures were isoniazid (n = 7, rifampicin (n = 6, or ethambutol (n = 6. Of note, severe allergic reactions (Stevens–Johnson syndrome (n = 4, erythema multiforme (n = 3, and drug rash with eosinophilia and systemic syndrome (n = 1 were included. All patients underwent resolution of the previous allergic reactions before desensitization. The median duration of desensitization was 18 days. The success rate was 78.9%. The allergic reactions following failed desensitization were not severe; most were maculopapular rashes. Conclusions: The desensitization protocol for anti-tuberculosis drugs was associated with a high success rate, and the individuals who failed desensitization experienced mild allergic reactions. Keywords: Desensitization, Antituberculosis, Steven-Johnson syndrome, Allergic drug reaction, Tolerance induction, Drug allergy

  2. Nonlinear poisson brackets geometry and quantization

    CERN Document Server

    Karasev, M V

    2012-01-01

    This book deals with two old mathematical problems. The first is the problem of constructing an analog of a Lie group for general nonlinear Poisson brackets. The second is the quantization problem for such brackets in the semiclassical approximation (which is the problem of exact quantization for the simplest classes of brackets). These problems are progressively coming to the fore in the modern theory of differential equations and quantum theory, since the approach based on constructions of algebras and Lie groups seems, in a certain sense, to be exhausted. The authors' main goal is to describe in detail the new objects that appear in the solution of these problems. Many ideas of algebra, modern differential geometry, algebraic topology, and operator theory are synthesized here. The authors prove all statements in detail, thus making the book accessible to graduate students.

  3. Hypnosis Versus Systematic Desensitization in the Treatment of Test Anxiety

    Science.gov (United States)

    Melnick, Joseph; Russell, Ronald W.

    1976-01-01

    This study compared the effectiveness of systematic desensitization and the directed experience hypnotic technique in reducing self-reported test anxiety and increasing the academic performance of test-anxious undergraduates (N=36). The results are discussed as evidence for systematic desensitization as the more effective treatment in reducing…

  4. Antibacterial and antiadherent properties of silver dioxide-coated brackets

    OpenAIRE

    Rizwan A Gilani; S M Laxmikanth; C S Ramachandra; Sangeeta L Prasad; Sushruth Shetty; S D Vasudevan

    2017-01-01

    Introduction: Enamel demineralization after fixed orthodontic treatment can occur in 50% of patients. Brackets play a significant role in enamel demineralization. Silver has already been prooved to have antibacterial properties. Hence the present study is conducted to assess the antiadherent and antibacterial properties of photocatalytic silver dioxide (AgO2) surface modified stainless steel orthodontic brackets against S. mutans. Materials and Methods: 80 stainless steel brackets of maxillar...

  5. Corrosion behavior of self-ligating and conventional metal brackets

    Directory of Open Access Journals (Sweden)

    Lúcio Henrique Esmeraldo Gurgel Maia

    2014-04-01

    Full Text Available Objective: To test the null hypothesis that the aging process in self-ligating brackets is not higher than in conventional brackets. Methods: Twenty-five conventional (GN-3M/Unitek; GE-GAC; VE-Aditek and 25 self-ligating (SCs-3M/Unitek; INs-GAC; ECs-Aditek metal brackets from three manufacturers (n = 150 were submitted to aging process in 0.9% NaCl solution at a constant temperature of 37 ± 1ºC for 21 days. The content of nickel, chromium and iron ions in the solution collected at intervals of 7, 14 and 21 days was quantified by atomic absorption spectrophotometry. After the aging process, the brackets were analyzed by scanning electron microscopy (SEM under 22X and 1,000X magnifications. Results: Comparison of metal release in self-ligating and conventional brackets from the same manufacturer proved that the SCs group released more nickel (p < 0.05 than the GN group after 7 and 14 days, but less chromium (p < 0.05 after 14 days and less iron (p < 0.05 at the three experimental time intervals. The INs group released less iron (p < 0.05 than the GE group after 7 days and less nickel, chromium and iron (p < 0.05 after 14 and 21 days. The ECs group released more nickel, chromium and iron (p < 0.05 than the VE group after 14 days, but released less nickel and chromium (p < 0.05 after 7 days and less chromium and iron (p < 0.05 after 21 days. The SEM analysis revealed alterations on surface topography of conventional and self-ligating brackets. Conclusions: The aging process in self-ligating brackets was not greater than in conventional brackets from the same manufacturer. The null hypothesis was accepted.

  6. Clinical evaluation of the failure rates of metallic brackets

    Directory of Open Access Journals (Sweden)

    Fábio Lourenço Romano

    2012-04-01

    Full Text Available OBJECTIVES: The aim of this study was to evaluate in vivo the bonding of metallic orthodontic brackets with different adhesive systems. MATERIAL AND METHODS: Twenty patients (10.5-15.1 years old who had sought corrective orthodontic treatment at a University Orthodontic Clinic were evaluated. Brackets were bonded from the right second premolar to the left second premolar in the upper and lower arches using: Orthodontic Concise, conventional Transbond XT, Transbond XT without primer, and Transbond XT associated with Transbond Plus Self-etching Primer (TPSEP. The 4 adhesive systems were used in all patients using a split-mouth design; each adhesive system was used in one quadrant of each dental arch, so that each group of 5 patients received the same bonding sequence. Initial archwires were inserted 1 week after bracket bonding. The number of bracket failures for each adhesive system was quantified over a 6-month period. RESULTS: The number of debonded brackets was: 8- Orthodontic Concise, 2- conventional Transbond XT, 9- Transbond XT without primer, and 1- Transbond XT + TPSEP. By using the Kaplan-Meier methods, statistically significant differences were found between the materials (p=0.0198, and the Logrank test identified these differences. Conventional Transbond XT and Transbond XT + TPSEP adhesive systems were statistically superior to Orthodontic Concise and Transbond XT without primer (p<0.05. There was no statistically significant difference between the dental arches (upper and lower, between the dental arch sides (right and left, and among the quadrants. CONCLUSIONS: The largest number of bracket failures occurred with Orthodontic Concise and Transbond XT without primer systems and few bracket failures occurred with conventional Transbond XT and Transbond XT+TPSEP. More bracket failures were observed in the posterior region compared with the anterior region.

  7. Desensitization to Mycofenolate Mofetil: a novel 12 step protocol.

    Science.gov (United States)

    Smith, M; Gonzalez-Estrada, A; Fernandez, J; Subramanian, A

    2016-07-01

    The use of MMF has become standard practice in many solid organ transplant recipients due its efficacy and favorable risk profile compared to other immunosuppressants. There has been a single case report of successful MMF desensitization. However, this protocol did not follow current Drug practice parameters. We report a successful desensitization to MMF in a double heart-kidney transplant recipient.

  8. Quantization with maximally degenerate Poisson brackets: the harmonic oscillator!

    International Nuclear Information System (INIS)

    Nutku, Yavuz

    2003-01-01

    Nambu's construction of multi-linear brackets for super-integrable systems can be thought of as degenerate Poisson brackets with a maximal set of Casimirs in their kernel. By introducing privileged coordinates in phase space these degenerate Poisson brackets are brought to the form of Heisenberg's equations. We propose a definition for constructing quantum operators for classical functions, which enables us to turn the maximally degenerate Poisson brackets into operators. They pose a set of eigenvalue problems for a new state vector. The requirement of the single-valuedness of this eigenfunction leads to quantization. The example of the harmonic oscillator is used to illustrate this general procedure for quantizing a class of maximally super-integrable systems

  9. Experimental study of some mounting brackets to support fuel elements

    International Nuclear Information System (INIS)

    Aubert, M.; Poglia, S.; Roche, R.

    1958-09-01

    In an atomic pile with vertical channels, fuel elements are stacked on one another. According to a possible assembly, fuel element can be contained by a graphite sleeve and be supported by a mounting bracket in this sleeve. Sleeves are then stacked on one another. The authors report the investigation of different designs for these mounting brackets. They describe their mechanical role and their mechanical, aerodynamic, neutronic and test conditions. They report tests performed on brackets made in graphite and on brackets made in stainless steel and graphite, and discuss the obtained results

  10. Desensitization of delayed-type hypersensitivity in mice: suppressive environment

    Directory of Open Access Journals (Sweden)

    Takashi Katsura

    1993-01-01

    Full Text Available The systemic injection of high doses of antigen into a preimmunized animal results in transient unresponsiveness of cell-mediated immune responses. This phenomenon is known as desensitization. Serum interleukin 2 (IL-2 activity was found transiently in desensitized mice at 3 h after the antigen challenge. These mice could not reveal antigen nonspecific delayed-type hypersensitivity (DTH 1 d after the challenge. Specific suppression of DTH was observed at later stages. Sera from 3 h desensitized mice showed suppressive effects on DTH in preo immunized mice. Administration of recombinant IL-2 into preimmunized mice led to the failure of development of DTH to antigens. These observations suggest that IL-2 plays an important role in the suppressive environment.

  11. Optimal design of an extrusion process for a hinge bracket

    International Nuclear Information System (INIS)

    Na, Geum Ju; Jang, Myung Geun; Kim, Jong Bong

    2016-01-01

    This study considers process design in forming a hinge bracket. A thin hinge bracket is typically produced by bending a sheet panel or welding a hollow bar into a sheet panel. However, the hinge bracket made by bending or welding does not have sufficient durability in severe operating conditions because of the stress concentration in the bended region or the low corrosion resistance of the welded region. Therefore, this study uses forming to produce the hinge bracket part of a foldable container and to ensure durability in difficult operating conditions. An extrusion process for a T-shaped hinge bracket is studied using finite element analysis. Preliminary analysis shows that a very high forging load is required to form the bracket by forging. Therefore, extrusion is considered as a candidate process. Producing the part through the extrusion process enables many brackets to be made in a single extrusion and through successive cutting of the extruded part, thereby reducing the manufacturing cost. The design focuses on reducing the extrusion load and on ensuring shape accuracy. An initial billet is designed to reduce the extrusion load and to obtain a geometrically accurate part. The extruded part is bent frequently because of uneven material flow. Thus, extrusion die geometries are designed to obtain straight parts.

  12. Optimal design of an extrusion process for a hinge bracket

    Energy Technology Data Exchange (ETDEWEB)

    Na, Geum Ju; Jang, Myung Geun; Kim, Jong Bong [Seoul National University, Seoul (Korea, Republic of)

    2016-05-15

    This study considers process design in forming a hinge bracket. A thin hinge bracket is typically produced by bending a sheet panel or welding a hollow bar into a sheet panel. However, the hinge bracket made by bending or welding does not have sufficient durability in severe operating conditions because of the stress concentration in the bended region or the low corrosion resistance of the welded region. Therefore, this study uses forming to produce the hinge bracket part of a foldable container and to ensure durability in difficult operating conditions. An extrusion process for a T-shaped hinge bracket is studied using finite element analysis. Preliminary analysis shows that a very high forging load is required to form the bracket by forging. Therefore, extrusion is considered as a candidate process. Producing the part through the extrusion process enables many brackets to be made in a single extrusion and through successive cutting of the extruded part, thereby reducing the manufacturing cost. The design focuses on reducing the extrusion load and on ensuring shape accuracy. An initial billet is designed to reduce the extrusion load and to obtain a geometrically accurate part. The extruded part is bent frequently because of uneven material flow. Thus, extrusion die geometries are designed to obtain straight parts.

  13. A successful desensitization protocol for horse-derived antithymocyte globulin in severe aplastic anemia.

    Science.gov (United States)

    Demir, Esen; Cigerci Günaydın, Nurşen; Karadaş, Nihal; Gülen, Figen; Tanac, Remziye; Yılmaz, Deniz

    2015-03-01

    Horse antithymocyte globulin (h-ATG) (ATGAM(®) ) is the first choice of treatment in very severe patients with aplastic anemia who do not have any HLA matched sibling donor. h-ATG is a heterologous serum that may cause anaphylaxis. Alternative treatment strategies must be planned in case of hypersensitivity. Desensitization must be considered in patients without an alternative treatment of choice. We aimed to present the h-ATG desensitization protocol and consider its effectiveness in patients with aplastic anemia who are hypersensitized with h-ATG and do not have an alternative treatment of choice. Skin prick tests were performed with non-diluted solution in eight very severe patients with aplastic anemia who are followed up in Ege University Children's Hospital. Although skin prick test was found negative in these eight patients, different dilution h-ATG intradermal tests were performed and found positive in all patients. h-ATG desensitization program was started to these hypersensitized patients. Desensitization program was started to six male and two female very severe patients with aplastic anemia whose ages were between seven and 19 yr (median: 12.9 yr). All of the patients completed the desensitization program. While local reaction was seen in two patients, systemic reaction was seen in one patient and late reaction was seen in one patient during and after desensitization program. A successful desensitization program with h-ATG in children with aplastic anemia is presented. Even though there is not an exposure before to such high allergy potential heterologous serum, skin tests should be performed and desensitization must be started to patients who are hypersensitized to h-ATG. As the expected effectiveness of the treatment is so much, the desensitization protocol can be carried out safely and effectively with trained stuff although allergic reactions can be seen. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Effect of Er:YAG Laser and Sandblasting in Recycling of Ceramic Brackets.

    Science.gov (United States)

    Yassaei, Soghra; Aghili, Hossein; Hosseinzadeh Firouzabadi, Azadeh; Meshkani, Hamidreza

    2017-01-01

    Introduction: This study was performed to determine the shear bond strength of rebonded mechanically retentive ceramic brackets after recycling with Erbium-Doped Yttrium Aluminum Garnet (Er:YAG) laser or sandblasting. Methods: Twenty-eight debonded ceramic brackets plus 14 intact new ceramic brackets were used in this study. Debonded brackets were randomly divided into 2 groups of 14. One group was treated by Er:YAG laser and the other with sandblasting. All the specimens were randomly bonded to 42 intact human upper premolars. The shear bond strength of all specimens was determined with a universal testing machine at a crosshead speed of 0.5 mm/min until bond failure occurred. The recycled bracket base surfaces were observed under a scanning electron microscope (SEM). Analysis of variance (ANOVA) and Tukey tests were used to compare the shear bond strength of the 3 groups. Fisher exact test was used to evaluate the differences in adhesive remnant index (ARI) scores. Results: The highest bond strength belonged to brackets recycled by Sandblasting (16.83 MPa). There was no significant difference between the shear bond strength of laser and control groups. SEM photographs showed differences in 2 recycling methods. The laser recycled bracket appeared to have as well-cleaned base as the new bracket. Although the sandblasted bracket photographs showed no remnant adhesives, remarkable micro-roughening of the base of the bracket was apparent. Conclusion: According to the results of this study, both Er:YAG laser and sandblasting were efficient to mechanically recondition retentive ceramic brackets. Also, Er:YAG laser did not change the design of bracket base while removing the remnant adhesives which might encourage its application in clinical practice.

  15. Anxiety Management Training and Self-Control Desensitization: 15 Months Later.

    Science.gov (United States)

    Deffenbacher, Jerry L.; Michaels, Ann C.

    1981-01-01

    A 15-month follow-up study found that anxiety management training and self-control desensitization groups continued to report significantly less debilitating test anxiety than the control group. Anxiety management training and self-control desensitization groups also reported significantly less nontargeted anxiety than controls on both measures of…

  16. A Controlled Study to Assess the Clinical Efficacy of Totally Self-Administered Systematic Desensitization

    Science.gov (United States)

    Rosen, Gerald M.; And Others

    1976-01-01

    Highly anxious self-referred snake phobics received either (a) therapist-administered desensitization, (b) self-administered desensitization with weekly therapist phone calls, (c) totally self-administered desensitization, (d) self-administered double-blind placebo control, or (e) no treatment. Pretreatment to posttreatment measures revealed…

  17. Exposure to Violence and Children's Desensitization Attitudes in Lebanon.

    Science.gov (United States)

    Tarabah, Asma; Badr, Lina Kurdahi; Usta, Jinan; Doyle, John

    2016-11-01

    Children exposed to multiple sources of violence may become desensitized, increasing the possibility of them imitating the aggressive behaviors they watch and considering such behavior as normal. The purpose of this article is to assess the association between exposure to various types of violence (including war) and desensitization in Lebanese children. A cross-sectional design with 207 school-aged children assessed exposure to violence using three surveys: (a) violence in the media (the Media Preference survey), (b) exposure to violence (the KID-SAVE survey), and (c) desensitization attitudes (the Attitude Toward Violence-Child Version). Children were between 8 and 12 years old, 56% were males, and 70%were from middle socioeconomic status (SES) backgrounds. Seventy-six percent of children reported being exposed to violence, with more exposure in males and in the lower SES group. Impact, however, was greater on girls. The predictors of attitude toward violence were "Frequency" of exposure, "Impact" of exposure, and the amount of violence viewed on television. Children are massively exposed to violence in Lebanon resulting in desensitization, which may habituate them to accept violence as normal and put them at risk for imitating violent behaviors. © The Author(s) 2015.

  18. Desensitization of stainless steels by laser surface heat-treatment

    Energy Technology Data Exchange (ETDEWEB)

    Nakao, Yoshikuni; Nishimoto, Kazutoshi

    1987-11-01

    Laser heating was applied for the desensitization heat-treatment of the surface layer in the sensitized HAZ of Type 304 stainless steel. The degree of sensitization was examined by EPR technique and the 10 % oxalic acid electrolytic etch test. The CO/sub 2/ laser with maximum power of 1.5 kW was used for heat-treatment. Time-Temperature-Desensitization diagram (TTDS diagram) for sensitized Type 304 stainless steels were developed by calculation assuming the chromium diffusion control for desensitization which might occur when the chromium depleted zone was healed up due to dissolution of chromium carbide and chromium diffusion from the matrix being heated at the solution annealing temperatures. TTDS diagrams calculated agree fairly well with ones determined by corrosion tests. Laser irradiation conditions (e.g., Laser power, beam diameter and traveling velocity) required for desensitization of sensitized Type 304 stainless steels were calculated using additivity rule from the TTDS diagram calculated and theoretical thermal curve of laser heating derived from the heat conduction theory. After laser beam irradiated under an optimum condition predicted by calculation, the sensitized HAZ of Type 304 stainless steel restored complete resistance to intergranular corrosion.

  19. Emotional Desensitization to Violence Contributes to Adolescents’ Violent Behavior

    Science.gov (United States)

    Mrug, Sylvie; Madan, Anjana; Windle, Michael

    2015-01-01

    Many adolescents are exposed to violence in their schools, communities and homes. Exposure to violence at high levels or across multiple contexts has been linked with emotional desensitization, indicated by low levels of internalizing symptoms. However, the long-term consequences of such desensitization are unknown. This study examined emotional desensitization to violence, together with externalizing problems, as mediators of the relationship between exposure to violence in pre-adolescence and violent behavior in late adolescence. A community sample of youth (N=704; 48% female; 76% African American, 22% Caucasian) reported on their exposure to violence in multiple settings at ages 11, 13 and 18. Internalizing and externalizing problems were assessed at ages 11 and 13; violent behavior was measured at age 18. Structural Equation Modeling showed that exposure to high levels of violence at age 11 was associated with lower levels of internalizing problems (quadratic effect) at age 13, as was exposure to violence across multiple contexts (linear effect). In turn, fewer internalizing problems and more externalizing problems at age 13 predicted more violent behavior at age 18. The results suggest that emotional desensitization to violence in early adolescence contributes to serious violence in late adolescence. PMID:25684447

  20. Emotional Desensitization to Violence Contributes to Adolescents' Violent Behavior.

    Science.gov (United States)

    Mrug, Sylvie; Madan, Anjana; Windle, Michael

    2016-01-01

    Many adolescents are exposed to violence in their schools, communities and homes. Exposure to violence at high levels or across multiple contexts has been linked with emotional desensitization, indicated by low levels of internalizing symptoms. However, the long-term consequences of such desensitization are unknown. This study examined emotional desensitization to violence, together with externalizing problems, as mediators of the relationship between exposure to violence in pre-adolescence and violent behavior in late adolescence. A community sample of youth (N = 704; 48% female; 76% African American, 22% Caucasian) reported on their exposure to violence in multiple settings at ages 11, 13 and 18. Internalizing and externalizing problems were assessed at ages 11 and 13; violent behavior was measured at age 18. Structural Equation Modeling showed that exposure to high levels of violence at age 11 was associated with lower levels of internalizing problems (quadratic effect) at age 13, as was exposure to violence across multiple contexts (linear effect). In turn, fewer internalizing problems and more externalizing problems at age 13 predicted more violent behavior at age 18. The results suggest that emotional desensitization to violence in early adolescence contributes to serious violence in late adolescence.

  1. Kidney transplantation after desensitization in sensitized patients: a Korean National Audit.

    Science.gov (United States)

    Huh, Kyu Ha; Kim, Beom Seok; Yang, Jaeseok; Ahn, Jeongmyung; Kim, Myung-Gyu; Park, Jae Berm; Kim, Jong Man; Chung, Byung-Ha; Kim, Joong Kyung; Kong, Jin Min

    2012-10-01

    The number of end-stage renal disease (ESRD) patients with preformed antibodies waiting for a kidney transplant has been increasing lately. We conducted a nationwide study on the outcomes of kidney transplantation after desensitization in Korea. Six transplant centers have run desensitization programs. The patients who underwent living donor kidney transplantation after desensitization from 2002 to 2010 were retrospectively analyzed. A total of 86 cases were enrolled. Thirty-five of these were cases of re-transplantation (40.7 %). Indications of desensitization were positive complement-dependent cytotoxicity (CDC) cross-match responses (CDC(+), 36.0 %), positive flow-cytometric cross-match responses (FCX(+), 54.7 %), and positive donor-specific antibodies (DSA(+), 8.1 %). The desensitization protocols used pre-transplant plasmapheresis (95.3 %), intravenous immunoglobulin (62.8 %), and rituximab (67.4 %). Acute rejection occurred in 18 patients (20.9 %), graft failure occurred in 4 patients, and the 3-year graft survival rate was 93.8 %. The presence of DSA increased the acute rejection rate (P = 0.015) and decreased the 1-year post-transplant estimated glomerular filtration rate (P = 0.006). Although rejection-free survival rates did not differ significantly between the CDC(+) and FCX(+) groups, the 1-year estimated glomerular filtration rate was lower in the CDC(+) group (P = 0.010). Infectious and significant bleeding complications occurred in 15.5 % and 4.7 % of cases, respectively. Kidney transplantation after desensitization had good graft outcomes and tolerable complications in Korea, and therefore, this therapy can be recommended for sensitized ESRD patients.

  2. Torsional strength of computer-aided design/computer-aided manufacturing-fabricated esthetic orthodontic brackets.

    Science.gov (United States)

    Alrejaye, Najla; Pober, Richard; Giordano Ii, Russell

    2017-01-01

    To fabricate orthodontic brackets from esthetic materials and determine their fracture resistance during archwire torsion. Computer-aided design/computer-aided manufacturing technology (Cerec inLab, Sirona) was used to mill brackets with a 0.018 × 0.025-inch slot. Materials used were Paradigm MZ100 and Lava Ultimate resin composite (3M ESPE), Mark II feldspathic porcelain (Vita Zahnfabrik), and In-Ceram YZ zirconia (Vita Zahnfabrik). Ten brackets of each material were subjected to torque by a 0.018 × 0.025-inch stainless steel archwire (G&H) using a specially designed apparatus. The average moments and degrees of torsion necessary to fracture the brackets were determined and compared with those of commercially available alumina brackets, Mystique MB (Dentsply GAC). The YZ brackets were statistically significantly stronger than any other tested material in their resistance to torsion (P brackets. Resistance of MZ100 and Lava Ultimate composite resin brackets to archwire torsion was comparable to commercially available alumina ceramic brackets.

  3. Shear bond strength of precoated orthodontic brackets: an in vivo study

    OpenAIRE

    Hassan, Ali H

    2010-01-01

    Ali H HassanDepartment of Preventive Dental Sciences, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi ArabiaObjective: To evaluate the shear bond strength of precoated orthodontic brackets bonded with self-etching primer relative to that of noncoated conventionally-bonded brackets at two different time intervals.Methods: Twenty-one subjects were selected for randomized split-mouth bonding of two types of brackets to the maxillary arch. Half of the teeth had precoated brackets b...

  4. A quantitative AFM analysis of nano-scale surface roughness in various orthodontic brackets.

    Science.gov (United States)

    Lee, Gi-Ja; Park, Ki-Ho; Park, Young-Guk; Park, Hun-Kuk

    2010-10-01

    In orthodontics, the surface roughnesses of orthodontic archwire and brackets affect the effectiveness of arch-guided tooth movement, corrosion behavior, and the aesthetics of orthodontic components. Atomic force microscopy (AFM) measurements were used to provide quantitative information on the surface roughness of the orthodontic material. In this study, the changes in surface roughness of various orthodontic bracket slots before and after sliding movement of archwire in vitro and in vivo were observed through the utilization of AFM. Firstly, we characterized the surface of four types of brackets slots as follows: conventional stainless steel (Succes), conventional ceramic (Perfect), self-ligating stainless steel (Damon) and self-ligating ceramic (Clippy-C) brackets. Succes) and Damon brackets showed relatively smooth surfaces, while Perfect had the roughest surface among the four types of brackets used. Secondly, after in vitro sliding test with beta titanium wire in two conventional brackets (Succes and Perfect), there were significant increases in only stainless steel bracket, Succes. Thirdly, after clinical orthodontic treatment for a maximum of 2 years, the self-ligating stainless steel bracket, Damon, showed a significant increase in surface roughness. But self-ligating ceramic brackets, Clippy-C, represented less significant changes in roughness parameters than self-ligating stainless steel ones. Based on the results of the AFM measurements, it is suggested that the self-ligating ceramic bracket has great possibility to exhibit less friction and better biocompatibility than the other tested brackets. This implies that these bracket slots will aid in the effectiveness of arch-guided tooth movement.

  5. Biocompatibility of nanosilver-coated orthodontic brackets: an in vivo study.

    Science.gov (United States)

    Metin-Gürsoy, Gamze; Taner, Lale; Barış, Emre

    2016-12-01

    Nanosilver particles of which antibacterial and antifungal properties have been shown in various in vitro and in vivo studies are used in many medical and dental fields for the prevention of infection. In this study, it is intended to evaluate the biocompatibility of nanosilver-coated brackets. Nanosilver coating process was applied to the standard orthodontic brackets by a physical vapor deposition system. Brackets were coated with nanosilver particles of 1 μ thickness. A total of 12 Wistar Albino rats were included in the study (six) and control (six) groups. For the study and control groups, four nanosilver-coated and four standard brackets were aseptically implanted subcutaneously in the dorsal region of each rat. The brackets were removed with the surrounding tissues on days 7, 14, 30, and 60. The specimens were evaluated for inflammatory response. No significant difference was found in terms of tissue reaction between the study and control groups. On day 7, randomly distributed brown-black granules were seen in the granulation tissue adjacent to the bracket in the study group. These foreign particles continued along the bracket cavity in a few samples, but the inflammatory response was insignificant between the groups. Mast cell count was found to be significantly smaller only on day 7 in the study group than in the control group. Nanosilver-coated orthodontic brackets were found to be similar with the standard type concerning inflammation. Further researches are needed with regard to the assessment of the brown-black granules, especially on the deposition of the vessel walls.

  6. Biocompatibility of nanosilver-coated orthodontic brackets: an in vivo study

    Directory of Open Access Journals (Sweden)

    Gamze Metin-Gürsoy

    2016-12-01

    Full Text Available Abstract Background Nanosilver particles of which antibacterial and antifungal properties have been shown in various in vitro and in vivo studies are used in many medical and dental fields for the prevention of infection. In this study, it is intended to evaluate the biocompatibility of nanosilver-coated brackets. Methods Nanosilver coating process was applied to the standard orthodontic brackets by a physical vapor deposition system. Brackets were coated with nanosilver particles of 1 μ thickness. A total of 12 Wistar Albino rats were included in the study (six and control (six groups. For the study and control groups, four nanosilver-coated and four standard brackets were aseptically implanted subcutaneously in the dorsal region of each rat. The brackets were removed with the surrounding tissues on days 7, 14, 30, and 60. The specimens were evaluated for inflammatory response. Results No significant difference was found in terms of tissue reaction between the study and control groups. On day 7, randomly distributed brown-black granules were seen in the granulation tissue adjacent to the bracket in the study group. These foreign particles continued along the bracket cavity in a few samples, but the inflammatory response was insignificant between the groups. Mast cell count was found to be significantly smaller only on day 7 in the study group than in the control group. Conclusions Nanosilver-coated orthodontic brackets were found to be similar with the standard type concerning inflammation. Further researches are needed with regard to the assessment of the brown-black granules, especially on the deposition of the vessel walls.

  7. [Acetylsalicylic acid desensitization in the new era of percutaneous coronary intervention].

    Science.gov (United States)

    Fuertes Ferre, Georgina; Ferrer Gracia, Maria Cruz; Calvo Cebollero, Isabel

    2015-09-21

    Dual antiplatelet therapy is essential in patients undergoing percutaneous coronary intervention with stent implantation. Hypersensitivity to acetylsalicylic acid (ASA) limits treatment options. Desensitization to ASA has classically been studied in patients with respiratory tract disease. Over the last years, many protocols have been described about ASA desensitization in patients with ischemic heart disease, including acute coronary syndrome and the need for coronary stent implantation. It is important to know the efficacy and safety of ASA desensitization in these patients. Copyright © 2014 Elsevier España, S.L.U. All rights reserved.

  8. Desensitizing nano powders to electrostatic discharge ignition

    International Nuclear Information System (INIS)

    Steelman, Ryan; Daniels, Michael A.

    2015-01-01

    Electrostatic discharge (ESD) is a main cause for ignition in powder media ranging from grain silos to fireworks. Nanoscale particles are orders of magnitude more ESD ignition sensitive than their micron scale counterparts. This study shows that at least 13 vol. % carbon nanotubes (CNT) added to nano-aluminum and nano-copper oxide particles (nAl + CuO) eliminates ESD ignition sensitivity. The CNT act as a conduit for electric energy and directs electric charge through the powder to desensitize the reactive mixture to ignition. For nanoparticles, the required CNT concentration for desensitizing ESD ignition acts as a diluent to quench energy propagation.

  9. Laser guided automated calibrating system for accurate bracket ...

    African Journals Online (AJOL)

    It is widely recognized that accurate bracket placement is of critical importance in the efficient application of biomechanics and in realizing the full potential of a preadjusted edgewise appliance. Aim: The purpose of ... placement. Keywords: Hough transforms, Indirect bonding technique, Laser, Orthodontic bracket placement ...

  10. Air-powder polishing on self-ligating brackets after clinical use: effects on debris levels.

    Science.gov (United States)

    Aragón, Mônica L S Castro; Lima, Leandro Santiago; Normando, David

    2016-01-01

    Debris buildup on brackets and arch surfaces is one of the main factors that can influence the intensity of friction between bracket and orthodontic wire. This study sought to evaluate the effect of air-powder polishing cleaning on debris levels of self-ligating ceramic brackets at the end of orthodontic treatment, compared to the behavior of conventional brackets. Debris levels were evaluated in metal conventional orthodontic brackets (n = 42) and ceramic self-ligating brackets (n = 42) on canines and premolars, arranged in pairs. There were brackets with and without air-powder polishing. At the end of orthodontic treatment, a hemiarch served as control and the contralateral hemiarch underwent prophylaxis with air-powder polishing. Debris buildup in bracket slots was assessed through images, and Wilcoxon test was used to analyze the results. The median debris levels were statistically lower in the conventional metal brackets compared to self-ligating ones (p = 0.02), regarding brackets not submitted to air-powder polishing. Polishing significantly reduced debris buildup to zero in both systems, without differences between groups. Ceramic self-ligating brackets have a higher debris buildup in comparison to conventional metal brackets in vivo, but prophylaxis with sodium bicarbonate jet was effective in reducing debris levels in self-ligating and also in conventional brackets.

  11. Prototype to measure bracket debonding force in vivo

    Directory of Open Access Journals (Sweden)

    Jéssika Lagni Tonus

    Full Text Available ABSTRACT Introduction: Material biodegradation that occurs in the mouth may interfere in the bonding strength between the bracket and the enamel, causing lower bond strength values in vivo, in comparison with in vitro studies. Objective: To develop a prototype to measure bracket debonding force in vivo and to evaluate, in vitro, the bond strength obtained with the prototype. Methods: A original plier (3M Unitek was modified by adding one strain gauge directly connected to its claw. An electronic circuit performed the reading of the strain gauge, and the software installed in a computer recorded the values of the bracket debonding force, in kgf. Orthodontic brackets were bonded to the facial surface of 30 bovine incisors with adhesive materials. In Group 1 (n = 15, debonding was carried out with the prototype, while tensile bond strength testing was performed in Group 2 (n = 15. A universal testing machine was used for the second group. The adhesive remnant index (ARI was recorded. Results: According to Student’s t test (α = 0.05, Group 1 (2.96 MPa and Group 2 (3.08 MPa were not significantly different. ARI score of 3 was predominant in the two groups. Conclusion: The prototype proved to be reliable for obtaining in vivo bond strength values for orthodontic brackets.

  12. Prototype to measure bracket debonding force in vivo

    Science.gov (United States)

    Tonus, Jéssika Lagni; Manfroi, Fernanda Borguetti; Borges, Gilberto Antonio; Grigolo, Eduardo Correa; Helegda, Sérgio; Spohr, Ana Maria

    2017-01-01

    ABSTRACT Introduction: Material biodegradation that occurs in the mouth may interfere in the bonding strength between the bracket and the enamel, causing lower bond strength values in vivo, in comparison with in vitro studies. Objective: To develop a prototype to measure bracket debonding force in vivo and to evaluate, in vitro, the bond strength obtained with the prototype. Methods: A original plier (3M Unitek) was modified by adding one strain gauge directly connected to its claw. An electronic circuit performed the reading of the strain gauge, and the software installed in a computer recorded the values of the bracket debonding force, in kgf. Orthodontic brackets were bonded to the facial surface of 30 bovine incisors with adhesive materials. In Group 1 (n = 15), debonding was carried out with the prototype, while tensile bond strength testing was performed in Group 2 (n = 15). A universal testing machine was used for the second group. The adhesive remnant index (ARI) was recorded. Results: According to Student’s t test (α = 0.05), Group 1 (2.96 MPa) and Group 2 (3.08 MPa) were not significantly different. ARI score of 3 was predominant in the two groups. Conclusion: The prototype proved to be reliable for obtaining in vivo bond strength values for orthodontic brackets. PMID:28444011

  13. Comparison of frictional resistance of esthetic and semi-esthetic self-ligating brackets

    Directory of Open Access Journals (Sweden)

    M S Kannan

    2015-01-01

    Full Text Available Aim: The frictional resistance encountered during sliding mechanics has been well established in the orthodontic literature, and it consists of complex interactions between the bracket, archwire, and method of ligation the claim of reduced friction with self-ligating brackets is often cited as a primary advantage over conventional brackets. This study was done to compare and evaluate the frictional forces generated between fully esthetic brackets and semi-aesthetic self-ligating brackets, which are of passive form and SEM (scanning electron microscope study of the Brackets after Frictional evaluation. Materials and Methods: Two types of self-ligating esthetic brackets, Damon clear (Ormco made of fully ceramic and Opal (Ultradent Products, USA and, Two types of self-ligating semi-esthetic brackets, Clarity SL (3M Unitek and Damon 3 (Ormco both of which are made of ceramic with metal slot. Arch wires with different dimensions and quality 17 × 25, 19 × 25 Titanium Molybdenum Alloy (TMA and 17 × 25, 19 × 25 stainless steel that came from plain strands of wire were used for frictional comparison test. The brackets used in this study had 0.022 × 0.028 inch slot. Results: The statistical tests showed significantly smaller amount of kinetic frictional forces is generated by Damon 3 (semi-esthetic self-ligating brackets. For each wire used, Damon 3 displayed significantly lower frictional forces (P ≤ 0.05 than any of the self-ligating system, followed by Opal (fully esthetic self-ligating brackets which generated smaller amount of frictional forces but relatively on the higher side when compared with Damon 3. Damon clear (fully esthetic self-ligating brackets generated the maximum amount of kinetic forces with all types of wire dimensions and properties when compared to the other three types of self-ligating system. Clarity SL (semi-esthetic self-ligating brackets generated smaller amount of frictional forces when compared with Damon clear and

  14. Comparison of frictional resistance of esthetic and semi-esthetic self-ligating brackets.

    Science.gov (United States)

    Kannan, M S; Murali, R V; Kishorekumar, S; Gnanashanmugam, K; Jayanth, V

    2015-04-01

    The frictional resistance encountered during sliding mechanics has been well established in the orthodontic literature, and it consists of complex interactions between the bracket, archwire, and method of ligation the claim of reduced friction with self-ligating brackets is often cited as a primary advantage over conventional brackets. This study was done to compare and evaluate the frictional forces generated between fully esthetic brackets and semi-aesthetic self-ligating brackets, which are of passive form and SEM (scanning electron microscope) study of the Brackets after Frictional evaluation. Two types of self-ligating esthetic brackets, Damon clear (Ormco) made of fully ceramic and Opal (Ultradent Products, USA) and, Two types of self-ligating semi-esthetic brackets, Clarity SL (3M Unitek) and Damon 3 (Ormco) both of which are made of ceramic with metal slot. Arch wires with different dimensions and quality 17 × 25, 19 × 25 Titanium Molybdenum Alloy (TMA) and 17 × 25, 19 × 25 stainless steel that came from plain strands of wire were used for frictional comparison test. The brackets used in this study had 0.022 × 0.028 inch slot. The statistical tests showed significantly smaller amount of kinetic frictional forces is generated by Damon 3 (semi-esthetic self-ligating brackets). For each wire used, Damon 3 displayed significantly lower frictional forces (P ≤ 0.05) than any of the self-ligating system, followed by Opal (fully esthetic self-ligating brackets) which generated smaller amount of frictional forces but relatively on the higher side when compared with Damon 3. Damon clear (fully esthetic self-ligating brackets) generated the maximum amount of kinetic forces with all types of wire dimensions and properties when compared to the other three types of self-ligating system. Clarity SL (semi-esthetic self-ligating brackets) generated smaller amount of frictional forces when compared with Damon clear and relatively higher amount of frictional forces

  15. A SAFE PROTOCOL FOR RAPID DESENSITIZATION IN PATIENTS WITH CYSTIC FIBROSIS AND ANTIBIOTIC HYPERSENSITIVITY

    Science.gov (United States)

    Legere, Henry J.; Palis, Ross I.; Bouza, Tito Rodriguez; Uluer, Ahmet Z.; Castells, Mariana C.

    2009-01-01

    Background CF patients often demonstrate hypersensitivity to one or multiple antibiotics due to frequent and repeated exposures. Attempts at antibiotic desensitization in this population are historically complicated by higher reaction rates, failure to complete the procedure and consequent withholding of first-line therapy. This study evaluates the outcomes of a rapid desensitization protocol developed at our institution. Methods We retrospectively reviewed the medical records of 15 patients undergoing 52 rapid antibiotic desensitizations at Brigham and Women’s Hospital and Children’s Hospital Boston utilizing our protocol. Results Mean FEV1 % predicted was 44.1 (SD 16.5), with two patients at desensitized during bilateral lung transplantation. Adverse reactions during desensitization occurred in 13.4%, and most were mild. 100% of patients completed the protocol and ultimately tolerated subsequent full-strength antibiotic courses. Conclusions CF patients with antibiotic hypersensitivity can safely receive first-line antibiotics via our rapid desensitization protocol, including those with severe obstructive lung disease. PMID:19740711

  16. Color stability of ceramic brackets immersed in potentially staining solutions.

    Science.gov (United States)

    Guignone, Bruna Coser; Silva, Ludimila Karsbergen; Soares, Rodrigo Villamarim; Akaki, Emilio; Goiato, Marcelo Coelho; Pithon, Matheus Melo; Oliveira, Dauro Douglas

    2015-01-01

    To assess the color stability of five types of ceramic brackets after immersion in potentially staining solutions. Ninety brackets were divided into 5 groups (n = 18) according to brackets commercial brands and the solutions in which they were immersed (coffee, red wine, coke and artificial saliva). The brackets assessed were Transcend (3M/Unitek, Monrovia, CA, USA), Radiance (American Orthodontics, Sheboygan, WI, USA), Mystique (GAC International Inc., Bohemia, NY, USA) and Luxi II (Rocky Mountain Orthodontics, Denver, CO, USA). Chromatic changes were analyzed with the aid of a reflectance spectrophotometer and by visual inspection at five specific time intervals. Assessment periods were as received from the manufacturer (T0), 24 hours (T1), 72 hours (T2), as well as 7 days (T3) and 14 days (T4) of immersion in the aforementioned solutions. Results were submitted to statistical analysis with ANOVA and Bonferroni correction, as well as to a multivariate profile analysis for independent and paired samples with significance level set at 5%. The duration of the immersion period influenced color alteration of all tested brackets, even though these changes could not always be visually observed. Different behaviors were observed for each immersion solution; however, brackets immersed in one solution progressed similarly despite minor variations. Staining became more intense over time and all brackets underwent color alterations when immersed in the aforementioned solutions.

  17. Self-Desensitization and Meditation in the Reduction of Public Speaking Anxiety.

    Science.gov (United States)

    Kirsch, Irving; Henry, David

    1979-01-01

    Speech-anxious students were assigned to self-administered treatment conditions: (1) systematic desensitization, (2) desensitization with meditation replacing progressive relaxation, and (3) meditation only. Treatment manuals included coping-skill instructions. Treatments were equally effective in reducing anxiety and produced a greater reduction…

  18. [Prolonged desensitization pretreatment for in vitro fertilization in women with polycystic ovary].

    Science.gov (United States)

    Kuczyński, W; Czech, R; Redźko, S; Wasilewski, T; Mrugacz, G; Wołczyński, S; Pietrewicz, P; Grochowski, D; Szamatowicz, M

    2000-09-01

    To analyse the outcome of intracytoplasmic sperm injection (ICSI) in women with severe polycystic ovary disease (PCD), stimulated after prolonged pituitary desensitization in comparison with regular long protocol therapy. The results of controlled ovarian hyperstimulation (COH), fertilization rate, early embryo development parameters and clinical pregnancy rates were compared depending on the duration of pituitary desensitization before gonadotropin administration. A total of 60 patients with severe PCOD were desensitized with GnRH agonist up to 30 days before COH. The results were compared with the group of 213 patients with mild PCOD treated with regular long protocol (control). We observed a slightly higher rate of mature oocytes MII as well as the number of embryos obtained in the control group, however the pregnancy rate in the group with prolonged desensitization was significantly higher (50%) in comparison to the control group (33.8%). The prolonged pituitary desensitization before controlled ovarian hyperstimulation gives better chance for obtaining pregnancy in patients with severe PCOD. It could be recommended facing previous treatment failure.

  19. Role of lubricants on friction between self-ligating brackets and archwires.

    Science.gov (United States)

    Leal, Renata C; Amaral, Flávia L B; França, Fabiana M G; Basting, Roberta T; Turssi, Cecilia P

    2014-11-01

    To evaluate the effect of different lubricants on friction between orthodontic brackets and archwires. Active (Quick, Forestadent) and passive (Damon 3MX, Ormco) self-ligating brackets underwent friction tests in the presence of mucin- and carboxymethylcellulose (CMC)-based artificial saliva, distilled water, and whole human saliva (positive control). Dry friction (no lubricant) was used as the negative control. Bracket/wire samples (0.014 × 0.025 inch, CuNiTi, SDS Ormco) underwent friction tests eight times in a universal testing machine. Two-way analysis of variance showed no significant interaction between bracket type and lubricant (P  =  .324). Friction force obtained with passive self-ligating brackets was lower than that for active brackets (P Friction observed in the presence of artificial saliva did not differ from that generated under lubrication with natural human saliva, as shown by Tukey test. Higher friction forces were found with the use of distilled water or when the test was performed under dry condition (ie, with no lubricant). Lubrication plays a role in friction forces between self-ligating brackets and CuNiTi wires, with mucin- and CMC-based artificial saliva providing a reliable alternative to human natural saliva.

  20. The Influence of No-Primer Adhesives and Anchor Pylons Bracket Bases on Shear Bond Strength of Orthodontic Brackets

    Directory of Open Access Journals (Sweden)

    Andrea Scribante

    2013-01-01

    Full Text Available Objective. The aim of this study was to compare the shear bond strength (SBS and adhesive remnant index (ARI scores of no-primer adhesives tested with two different bracket bases. Materials and Methods. 120 bovine permanent mandibular incisors were divided into 6 groups of 20 specimens. Two brackets (ODP with different bracket bases (anchor pylons and 80-gauge mesh were bonded to the teeth using a conventional adhesive (Transbond XT and two different no-primer adhesive (Ortho Cem; Heliosit systems. Groups were tested using an instron universal testing machine. SBS values were recorded. ARI scores were measured. SEM microphotographs were taken to evaluate the pattern of bracket bases. Statistical analysis was performed. ANOVA and Tukey tests were carried out for SBS values, whereas a chi-squared test was applied for ARI scores. Results. Highest bond strength values were reported with Transbond XT (with both pad designs, Ortho Cem bonded on anchor pylons and Heliosit on 80-gauge mesh. A higher frequency of ARI score of “3” was reported for Transbond XT groups. Other groups showed a higher frequency of ARI score “2” and “1.” Conclusion. Transbond XT showed the highest shear bond strength values with both pad designs.

  1. Desensitization to ceftaroline in a patient with multiple medication hypersensitivity reactions.

    Science.gov (United States)

    Jones, Justin M; Richter, Lisa M; Alonto, Augusto; Leedahl, David D

    2015-02-01

    The case of a patient with multiple medication hypersensitivity reactions and a methicillin-resistant Staphylococcus aureus (MRSA) infection who underwent desensitization to ceftaroline is reported. A 32-year-old Caucasian woman with asthma, gastroesophageal reflux disease, heart murmur, and major depression was admitted for MRSA cellulitis with a subcutaneous abscess along the left sternomanubrial joint and clavicular osteomyelitis secondary to port placement after gastric bypass surgery. The patient had an extensive history of hypersensitivity reactions. Pertinent documented allergies were as follows: penicillin (anaphylaxis), daptomycin (anaphylaxis), vancomycin (hives), linezolid (hives), ertapenem (rash), ciprofloxacin (rash), and tigecycline (rash). The patient also reported previous reactions to aztreonam (unknown) and gentamicin (hives). The pharmacy was consulted to develop a desensitization protocol for ceftaroline. The desensitization protocol used three serial dilutions of ceftaroline to make 14 sequential infusions with escalating doses. Intramuscular epinephrine, i.v. diphenhydramine, and i.v. methylprednisolone were ordered as needed for the development of immediate hypersensitivity reactions during or after administration of ceftaroline. The cumulative dose (574.94 mg) was administered intravenously over 225 minutes with no breakthrough symptoms reported during or after the desensitization protocol. Ceftaroline fosamil 600 mg i.v. every 12 hours was continued for six weeks. Desensitization to ceftaroline was conducted for a patient with extensive history of hypersensitivity reactions to other drugs, including penicillin-induced anaphylaxis. Desensitization and subsequent treatment with full doses of ceftaroline were accomplished without apparent adverse effects. Copyright © 2015 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  2. An Hourly Dose-Escalation Desensitization Protocol for Aspirin-Exacerbated Respiratory Disease.

    Science.gov (United States)

    Chen, Justin R; Buchmiller, Brett L; Khan, David A

    2015-01-01

    Aspirin desensitization followed by maintenance therapy effectively improves symptom control in patients with aspirin exacerbated respiratory disease (AERD). The majority of current desensitization protocols use 3-hour dosing intervals and often require 2 to 3 days to complete. We evaluated hourly dose escalations in a subset of patients with chronic rhinosinusitis, nasal polyps, and asthma who historically reacted to aspirin within 1 hour or were avoiding aspirin with the goal of developing a safe and efficient desensitization protocol. Fifty-seven aspirin desensitizations were performed under the hourly protocol. All patients had refractory nasal polyposis as an indication for aspirin desensitization. The clinical characteristics of each subject were analyzed in relation to aspects of his or her reactions during the procedure. Ninety-eight percent of study patients were successfully treated under the hourly protocol, including those with a history of severe reactions and intubation. None required further medication than is available in an outpatient allergy clinic. A total of 96% of reactors recorded a bronchial or naso-ocular reaction within 1 hour of the preceding dose. Of the total patients on this protocol, 40% were able to complete the procedure in a single day, and 60% within 2 days. Patients with AERD who have a history of symptoms less than 1 hour after aspirin exposure can be safely desensitized with a 1-hour dose-escalation protocol that can often be completed in a single day. Copyright © 2015 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  3. Spectrophotometric evaluation of dental bleaching under orthodontic bracket in enamel and dentin

    Science.gov (United States)

    Correr, Americo-Bortolazzo; Rastelli, Alessandra-Nara-Souza; Lima, Débora-Alves-Nunes-Leite; Consani, Rafael-Leonardo-Xediek

    2014-01-01

    Aware of the diffusion capacity of bleaching in the dental tissues, many orthodontists are subjecting their patients to dental bleaching during orthodontic treatment for esthetic purposes or to anticipate the exchange of esthetic restorations after the orthodontic treatment. For this purpose specific products have been developed in pre-loaded whitening trays designed to fit over and around brackets and wires, with clinical efficacy proven. Objective: The objective of this study was to evaluate, through spectrophotometric reflectance, the effectiveness of dental bleaching under orthodontic bracket. Material and Methods: Thirty-two bovine incisors crown blocks of 8 mm x 8 mm height lengths were used. Staining of tooth blocks with black tea was performed for six days. They were distributed randomly into 4 groups (1-home bleaching with bracket, 2- home bleaching without bracket, 3- office bleaching with bracket, 4 office bleaching without bracket). The color evaluation was performed (CIE L * a * b *) using color reflectance spectrophotometer. Metal brackets were bonded in groups 1 and 3. The groups 1 and 2 samples were subjected to the carbamide peroxide at 15%, 4 hours daily for 21 days. Groups 3 and 4 were subjected to 3 in-office bleaching treatment sessions, hydrogen peroxide 38%. After removal of the brackets, the second color evaluation was performed in tooth block, difference between the area under the bracket and around it, and after 7 days to verified color stability. Data analysis was performed using the paired t-test and two-way variance analysis and Tukey’s. Results: The home bleaching technique proved to be more effective compared to the office bleaching. There was a significant difference between the margin and center color values of the specimens that were subjected to bracket bonding. Conclusions: The bracket bond presence affected the effectiveness of both the home and office bleaching treatments. Key words:Tooth bleaching, spectrophotometry

  4. Friction between various self-ligating brackets and archwire couples during sliding mechanics.

    Science.gov (United States)

    Stefanos, Sennay; Secchi, Antonino G; Coby, Guy; Tanna, Nipul; Mante, Francis K

    2010-10-01

    The aim of this study was to evaluate the frictional resistance between active and passive self-ligating brackets and 0.019 × 0.025-in stainless steel archwire during sliding mechanics by using an orthodontic sliding simulation device. Maxillary right first premolar active self-ligating brackets In-Ovation R, In-Ovation C (both, GAC International, Bohemia, NY), and SPEED (Strite Industries, Cambridge, Ontario, Canada), and passive self-ligating brackets SmartClip (3M Unitek, Monrovia, Calif), Synergy R (Rocky Mountain Orthodontics, Denver, Colo), and Damon 3mx (Ormco, Orange, Calif) with 0.022-in slots were used. Frictional force was measured by using an orthodontic sliding simulation device attached to a universal testing machine. Each bracket-archwire combination was tested 30 times at 0° angulation relative to the sliding direction. Statistical comparisons were performed with 1-way analysis of variance (ANOVA) followed by Dunn multiple comparisons. The level of statistical significance was set at P <0.05. The Damon 3mx brackets had significantly the lowest mean static frictional force (8.6 g). The highest mean static frictional force was shown by the SPEED brackets (83.1 g). The other brackets were ranked as follows, from highest to lowest, In-Ovation R, In-Ovation C, SmartClip, and Synergy R. The mean static frictional forces were all statistically different. The ranking of the kinetic frictional forces of bracket-archwire combinations was the same as that for static frictional forces. All bracket-archwire combinations showed significantly different kinetic frictional forces except SmartClip and In-Ovation C, which were not significantly different from each other. Passive self-ligating brackets have lower static and kinetic frictional resistance than do active self-ligating brackets with 0.019 × 0.025-in stainless steel wire. Copyright © 2010 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  5. Dimensional accuracy of ceramic self-ligating brackets and estimates of theoretical torsional play.

    Science.gov (United States)

    Lee, Youngran; Lee, Dong-Yul; Kim, Yoon-Ji R

    2016-09-01

    To ascertain the dimensional accuracies of some commonly used ceramic self-ligation brackets and the amount of torsional play in various bracket-archwire combinations. Four types of 0.022-inch slot ceramic self-ligating brackets (upper right central incisor), three types of 0.018-inch ceramic self-ligating brackets (upper right central incisor), and three types of rectangular archwires (0.016 × 0.022-inch beta-titanium [TMA] (Ormco, Orange, Calif), 0.016 × 0.022-inch stainless steel [SS] (Ortho Technology, Tampa, Fla), and 0.019 × 0.025-inch SS (Ortho Technology)) were measured using a stereomicroscope to determine slot widths and wire cross-sectional dimensions. The mean acquired dimensions of the brackets and wires were applied to an equation devised by Meling to estimate torsional play angle (γ). In all bracket systems, the slot tops were significantly wider than the slot bases (P brackets, and Clippy-Cs (Tomy, Futaba, Fukushima, Japan) among the 0.018-inch brackets. The Damon Clear (Ormco) bracket had the smallest dimensional error (0.542%), whereas the 0.022-inch Empower Clear (American Orthodontics, Sheboygan, Wis) bracket had the largest (3.585%). The largest amount of theoretical play is observed using the Empower Clear (American Orthodontics) 0.022-inch bracket combined with the 0.016 × 0.022-inch TMA wire (Ormco), whereas the least amount occurs using the 0.018 Clippy-C (Tomy) combined with 0.016 × 0.022-inch SS wire (Ortho Technology).

  6. Desensitization strategies in adult heart transplantation-Will persistence pay off?

    Science.gov (United States)

    Chih, Sharon; Patel, Jignesh

    2016-08-01

    Strategies are needed to enable successful heart transplantation in highly sensitized patients. Immunologic challenges from sensitization to human leukocyte antigen (HLA) reduce access to compatible donors, extend waiting times to transplant, and increase the risks of antibody-mediated rejection and cardiac allograft vasculopathy after transplant. The prime goal of desensitization is to increase access to transplantation through expansion of the donor organ pool. Existing therapies are directed at key components of the humoral immune response with newer biologically based regimens able to target plasma cells as the source of antibody production, as well as complement activation that has a central role in antibody-mediated injury. Despite the emergence of early promising results for these agents, a significant knowledge gap remains with the current data for desensitization, extrapolated mostly from non-heart solid-organ transplants and small observational studies. Notably, no approach has demonstrated significant and sustainable reductions in HLA antibody pre-transplant, and the ideal desensitization strategy remains elusive. In addition, clinical tools to evaluate the humoral response and efficacy of therapy are limited, focusing almost exclusively on HLA antibody detection. Importantly, desensitization is associated with significant costs and potential risks, and overall long-term outcomes and cost-effectiveness have not been sufficiently evaluated. Investigation is ongoing into the development of a clinically effective desensitization strategy in heart transplantation. Copyright © 2016 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  7. Color stability of ceramic brackets immersed in potentially staining solutions

    Directory of Open Access Journals (Sweden)

    Bruna Coser Guignone

    2015-08-01

    Full Text Available OBJECTIVE: To assess the color stability of five types of ceramic brackets after immersion in potentially staining solutions.METHODS: Ninety brackets were divided into 5 groups (n = 18 according to brackets commercial brands and the solutions in which they were immersed (coffee, red wine, coke and artificial saliva. The brackets assessed were Transcend (3M/Unitek, Monrovia, CA, USA, Radiance (American Orthodontics, Sheboygan, WI, USA, Mystique (GAC International Inc., Bohemia, NY, USA and Luxi II (Rocky Mountain Orthodontics, Denver, CO, USA. Chromatic changes were analyzed with the aid of a reflectance spectrophotometer and by visual inspection at five specific time intervals. Assessment periods were as received from the manufacturer (T0, 24 hours (T1, 72 hours (T2, as well as 7 days (T3 and 14 days (T4 of immersion in the aforementioned solutions. Results were submitted to statistical analysis with ANOVA and Bonferroni correction, as well as to a multivariate profile analysis for independent and paired samples with significance level set at 5%.RESULTS: The duration of the immersion period influenced color alteration of all tested brackets, even though these changes could not always be visually observed. Different behaviors were observed for each immersion solution; however, brackets immersed in one solution progressed similarly despite minor variations.CONCLUSIONS: Staining became more intense over time and all brackets underwent color alterations when immersed in the aforementioned solutions.

  8. Effects of recycling and bonding agent application on bond strength of stainless steel orthodontic brackets.

    Science.gov (United States)

    Bahnasi, Faisal I; Abd-Rahman, Aida Na; Abu-Hassan, Mohame I

    2013-10-01

    1) to assess different methods of recycling orthodontic brackets, 2) to evaluate Shear Bond Strength (SBS) of (a) new, (b) recycled and (c) repeated recycled stainless steel brackets (i) with and (ii) without bracket base primer. A total of 180 extracted human premolar teeth and 180 premolar stainless steel brackets were used. One hundred teeth and 100 brackets were divided into five groups of 20-teeth each. Four methods of recycling orthodontic brackets were used in each of the first four groups while the last one (group V) was used as the control. Groups (I-V) were subjected to shear force within half an hour until the brackets debond. SBS was measured and the method showing the highest SBS was selected. A New group (VI) was recycled twice with the selected method. Six subgroups (1-6) were established; the primer was applied for three sub-groups, and the composite was applied for all brackets. Brackets were subjected to the same shear force, and SBS was measured for all sub-groups. There was a significant difference between the mean SBS of the sandblasting method and the means of SBS of each of the other three methods. There was however, no significant difference between the mean SBS of the new bracket and the mean SBS of recycled bracket using sandblasting. The mean SBS of all sub-groups were more than that recommended by Reynolds (17) in 1975. Brackets with primer showed slightly higher SBS compared to those of brackets without bonding agent. To decrease cost, sandblasted recycled orthodontic brackets can be used as an alternative to new brackets. It is recommended to apply a bonding agent on the bracket base to provide greater bond strength. Key words:Recycled bracket, shear bond strength, sandblasting, stainless steel orthodontic bracket.

  9. Effects of recycling and bonding agent application on bond strength of stainless steel orthodontic brackets

    Science.gov (United States)

    Bahnasi, Faisal I.; Abu-Hassan, Mohame I.

    2013-01-01

    Objectives: 1) to assess different methods of recycling orthodontic brackets, 2) to evaluate Shear Bond Strength (SBS) of (a) new, (b) recycled and (c) repeated recycled stainless steel brackets (i) with and (ii) without bracket base primer. Study Design: A total of 180 extracted human premolar teeth and 180 premolar stainless steel brackets were used. One hundred teeth and 100 brackets were divided into five groups of 20-teeth each. Four methods of recycling orthodontic brackets were used in each of the first four groups while the last one (group V) was used as the control. Groups (I-V) were subjected to shear force within half an hour until the brackets debond. SBS was measured and the method showing the highest SBS was selected. A New group (VI) was recycled twice with the selected method. Six subgroups (1-6) were established; the primer was applied for three sub-groups, and the composite was applied for all brackets. Brackets were subjected to the same shear force, and SBS was measured for all sub-groups. Results: There was a significant difference between the mean SBS of the sandblasting method and the means of SBS of each of the other three methods. There was however, no significant difference between the mean SBS of the new bracket and the mean SBS of recycled bracket using sandblasting. The mean SBS of all sub-groups were more than that recommended by Reynolds (17) in 1975. Brackets with primer showed slightly higher SBS compared to those of brackets without bonding agent. Conclusion: To decrease cost, sandblasted recycled orthodontic brackets can be used as an alternative to new brackets. It is recommended to apply a bonding agent on the bracket base to provide greater bond strength. Key words:Recycled bracket, shear bond strength, sandblasting, stainless steel orthodontic bracket. PMID:24455081

  10. [Comparison of root resorption between self-ligating and conventional brackets using cone-beam CT].

    Science.gov (United States)

    Liu, Yun; Guo, Hong-ming

    2016-04-01

    To analyze the differences of root resorption between passive self-ligating and conventional brackets, and to determine the relationship between passive self-ligating brackets and root resorption. Fifty patients were randomly divided into 2 groups using passive self-ligating brackets or conventional straight wire brackets (0.022 system), respectively. Cone-beam CT was taken before and after treatment. The amount of external apical root resorption of maxillary incisors was measured on CBCT images. Student's t test was performed to analyze the differences of root apical resorption between the 2 groups with SPSS17.0 software package. No significant difference(P> 0.05) in root resorption of maxillary incisors was found between passive self-ligating brackets and conventional brackets. Passive self-ligating brackets and conventional brackets can cause root resorption, but the difference was not significant. Passive self-ligating brackets do not induce more root resorption.

  11. Desensitization Using Bortezomib and High-dose Immunoglobulin Increases Rate of Deceased Donor Kidney Transplantation.

    Science.gov (United States)

    Jeong, Jong Cheol; Jambaldorj, Enkthuya; Kwon, Hyuk Yong; Kim, Myung-Gyu; Im, Hye Jin; Jeon, Hee Jung; In, Ji Won; Han, Miyeun; Koo, Tai Yeon; Chung, Junho; Song, Eun Young; Ahn, Curie; Yang, Jaeseok

    2016-02-01

    Combination therapy of intravenous immunoglobulin (IVIG) and rituximab showed a good transplant rate in highly sensitized wait-listed patients for deceased donor kidney transplantation (DDKT), but carried the risk of antibody-mediated rejection. The authors investigated the impact of a new combination therapy of bortezomib, IVIG, and rituximab on transplantation rate.This study was a prospective, open-labeled clinical trial. The desensitization regimen consisted of 2 doses of IVIG (2  g/kg), a single dose of rituximab (375  mg/m), and 4 doses of bortezomib (1.3  mg/m). The transplant rate was analyzed. Anti-Human leukocyte antigen (HLA) DRB antibodies were determined by a Luminex solid-phase bead assay at baseline and after 2, 3, and 6 months in the desensitized patients.There were 19 highly sensitized patients who received desensitization and 17 patients in the control group. Baseline values of class I and II panel reactive antibody (%, peak mean fluorescence intensity) were 83  ±  16.0 (14952  ±  5820) and 63  ±  36.0 (10321  ±  7421), respectively. Deceased donor kidney transplantation was successfully performed in 8 patients (42.1%) in the desensitization group versus 4 (23.5%) in the control group. Multivariate time-varying covariate Cox regression analysis showed that desensitization increased the probability of DDKT (hazard ratio, 46.895; 95% confidence interval, 3.468-634.132; P = 0.004). Desensitization decreased mean fluorescence intensity values of class I panel reactive antibody by 15.5% (20.8%) at 2 months. In addition, a liberal mismatch strategy in post hoc analysis increased the benefit of desensitization in donor-specific antibody reduction. Desensitization was well tolerated, and acute rejection occurred only in the control group.In conclusion, a desensitization protocol using bortezomib, high-dose IVIG, and rituximab increased the DDKT rate in highly sensitized, wait-listed patients.

  12. Effectiveness of Structured Psychodrama and Systematic Desensitization in Reducing Test Anxiety.

    Science.gov (United States)

    Kipper, David A.; Giladi, Daniel

    1978-01-01

    Students with examination anxiety took part in study of effectiveness of two kinds of treatment, structured psychodrama and systematic desensitization, in reducing test anxiety. Results showed that subjects in both treatment groups significantly reduced test-anxiety scores. Structured psychodrama is as effective as systematic desensitization in…

  13. Cognitive Modification and Systematic Desensitization with Test Anxious High School Students.

    Science.gov (United States)

    Leal, Lois L.; And Others

    1981-01-01

    Compares the relative effectiveness of cognitive modification and systematic desensitization with test anxious high school students (N=30). The systematic desensitization treatment appeared to be significantly more effective on the performance measure while cognitive modification was more effective on one of the self-report measures. (Author/JAC)

  14. Mandibular Dental Arch Changes with Active Self‑ligating Brackets ...

    African Journals Online (AJOL)

    ... with different forms of archwires with a control group in nonextraction cases. ... into three groups: Group I was treated with active self‑ligating brackets (Nexus, ... (SS) wires; Group II was treated with interactive self‑ligating bracket system ...

  15. Therapeutic efficacy of self-ligating brackets: A systematic review.

    Science.gov (United States)

    Dehbi, Hasnaa; Azaroual, Mohamed Faouzi; Zaoui, Fatima; Halimi, Abdelali; Benyahia, Hicham

    2017-09-01

    Over the last few years, the use of self-ligating brackets in orthodontics has progressed considerably. These systems have been the subject of numerous studies with good levels of evidence making it possible to evaluate their efficacy and efficiency compared to conventional brackets. The aim of this study was to evaluate the therapeutic efficacy of self-ligating brackets by means of a systematic review of the scientific literature. A systematic study was undertaken in the form of a recent search of the electronic Pubmed database, oriented by the use of several keywords combined by Boolean operators relating to the therapeutic efficacy of self-ligating brackets through the study of tooth alignment, space closure, expansion, treatment duration and degree of discomfort. The search was limited to randomized controlled studies, and two independent readers identified studies corresponding to the selection criteria. The chosen articles comprised 20 randomized controlled trials. The studies analyzed revealed the absence of significant differences between the two types of system on the basis of the clinical criteria adopted, thereby refuting the hypothesis of the superiority of self-ligating brackets over conventional systems. Copyright © 2017 CEO. Published by Elsevier Masson SAS. All rights reserved.

  16. Adhesion of periodontal pathogens to self-ligating orthodontic brackets: An in-vivo prospective study.

    Science.gov (United States)

    Jung, Woo-Sun; Kim, Kyungsun; Cho, Soha; Ahn, Sug-Joon

    2016-09-01

    Our aims were to analyze adhesion of periodontopathogens to self-ligating brackets (Clarity-SL [CSL], Clippy-C [CC] and Damon Q [DQ]) and to identify the relationships between bacterial adhesion and oral hygiene indexes. Central incisor brackets from the maxilla and mandible were collected from 60 patients at debonding after the plaque and gingival indexes were measured. Adhesions of Aggregatibacter actinomycetemcomitans (Aa), Porphyromonas gingivalis (Pg), Prevotella intermedia (Pi), Fusobacterium nucleatum (Fn), and Tannerella forsythia (Tf) were quantitatively determined using real-time polymerase chain reactions. Factorial analysis of variance was used to analyze bacterial adhesion in relation to bracket type and jaw position. Correlation coefficients were calculated to determine the relationships between bacterial adhesion and the oral hygiene indexes. Total bacteria showed greater adhesion to CSL than to DQ brackets, whereas Aa, Pg, and Pi adhered more to DQ than to CSL brackets. CC brackets showed an intermediate adhesion pattern between CSL and DQ brackets, but it did not differ significantly from either bracket type. Adhesion of Fn and Tf did not differ significantly among the 3 brackets. Most bacteria were detected in greater quantities in the mandibular than in the maxillary brackets. The plaque and gingival indexes were not strongly correlated with bacterial adhesion to the brackets. Because Aa, Pg, and Pi adhered more to the DQ brackets in the mandibular area, orthodontic patients with periodontal problems should be carefully monitored in the mandibular incisors where the distance between the bracket and the gingiva is small, especially when DQ brackets are used. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  17. A comparative assessment of forces and moments generated by lingual and conventional brackets

    NARCIS (Netherlands)

    Sifakakis, I.; Pandis, N.; Makou, M.; Katsaros, C.; Eliades, T.; Bourauel, C.

    2013-01-01

    The aim of this study was to assess the effect of bracket type on the labiopalatal forces and moments generated in the sagittal plane. Incognito lingual brackets (3M Unitek), STb lingual brackets (Light Lingual System; ORMCO), and conventional 0.018 inch slot brackets (Gemini; 3M Unitek) were bonded

  18. Light energy attenuation through orthodontic ceramic brackets at different irradiation times.

    Science.gov (United States)

    Santini, Ario; Tiu, Szu Hui; McGuinness, Niall J P; Aldossary, Mohammed Saeed

    2016-09-01

    To evaluate the total light energy (TLE) transmission through three types of ceramic brackets with, bracket alone and with the addition of orthodontic adhesive, at different exposure durations, and to compare the microhardness of the cured adhesive. Three different makes of ceramic brackets, Pure Sapphire(M), Clarity™ ADVANCED(P) and Dual Ceramic(P) were used. Eighteen specimens of each make were prepared and allocated to three groups (n = 6). MARC(®)-resin calibrator was used to determine the light curing unit (LCU) tip irradiance (mW/cm(2)) and TLE (J/cm(2)) transmitted through the ceramic brackets, and through ceramic bracket plus Transbond™ XT Light Cure Adhesive, for 5, 10 and 20 s. Vickers-hardness values at the bottom of the cured adhesive were determined. Statistical analysis used one-way analysis of variance (ANOVA); P = 0.05. TLE transmission rose significantly among all samples with increasing exposure durations. TLE reaching the adhesive- enamel interface was less than 10 J/cm(2), and through monocrystalline and polycrystalline ceramic brackets was significantly different (P brackets. Clinicians are advised to measure the tip irradiance of their LCUs and increase curing time beyond 5 s. Orthodontic clinicians should understand the type of light curing device and the orthodontic adhesive used in their practice.

  19. Detrimental Effects of a Self-reward Contracting Program on Subjects' Involvement in Self-administered Desensitization

    Science.gov (United States)

    Barrera, Manuel Jr.; Rosen, Gerald M.

    1977-01-01

    Assesses a self-reward contracting procedure intended to facilitate completion of self-administered desensitization. Self-referred snake phobics received either (a) self-administered desensitization; (b) self-administered desensitization with self-reward contracting; or (c) a self-administered placebo with self-reward contracting. Results show the…

  20. Behavior Modification Through Covert Semantic Desensitization

    Science.gov (United States)

    Hekmat, Hamid; Vanian, Daniel

    1971-01-01

    Results support the hypothesized relationship between meaning and phobia. Semantic desensitization techniques based on counter conditioning of meaning were significantly effective in altering the semantic value of the word from unpleasantness to neutrality. (Author)

  1. Desensitization to inhaled aztreonam lysine in an allergic patient with cystic fibrosis using a novel approach.

    Science.gov (United States)

    Guglani, Lokesh; Abdulhamid, Ibrahim; Ditouras, Joanna; Montejo, Jenny

    2012-10-01

    To report the successful desensitization of a highly allergic patient with cystic fibrosis (CF) to inhaled aztreonam lysine using the novel approach of intravenous desensitization followed by full-dose inhaled therapy without any adverse reactions. A 19-year-old woman with CF had persistent Pseudomonas aeruginosa-positive cultures and a history of type I hypersensitivity reactions to multiple medications, including aztreonam and tobramycin (intravenous and inhaled). To start therapy with an inhaled antipseudomonal antibiotic on a chronic basis, she underwent rapid desensitization to intravenous aztreonam followed by initiation of inhaled aztreonam lysine. Following intravenous desensitization with aztreonam, there was no adverse reaction or decline in lung function noted with inhaled aztreonam lysine and the chronic therapy was continued at home, with a modified regimen to maintain desensitization. Aztreonam lysine has been used for treatment of patients with CF with chronic P. aeruginosa colonization. Previous allergic reaction to intravenous aztreonam is considered a contraindication for use of aztreonam lysine. Our patient had a history of hives and facial swelling following administration of intravenous aztreonam (type I hypersensitivity reaction) as well as hypersensitivity to tobramycin. Rapid desensitization can be done for drugs that mediate a type I hypersensitivity reaction, with mast cells and basophils being the cellular targets. There are a few case reports of desensitization to inhaled antibiotics such as tobramycin and colistin, but desensitization to aztreonam lysine has not previously been reported. Desensitization of a patient with CF who is allergic to intravenous aztreonam was successfully accomplished with the novel approach of rapid intravenous desensitization followed by inhaled therapy. As inhaled antibiotics are being increasingly used for patients with CF, this novel strategy can be used for desensitizing allergic patients with CF to

  2. Adhesives for fixed orthodontic brackets.

    Science.gov (United States)

    Mandall, N A; Millett, D T; Mattick, C R; Hickman, J; Macfarlane, T V; Worthington, H V

    2003-01-01

    Bonding of orthodontic brackets to teeth is important to enable effective and efficient treatment with fixed appliances. The problem is bracket failure during treatment which increases operator chairside time and lengthens treatment time. A prolonged treatment is likely to increase the oral health risks of orthodontic treatment with fixed appliances one of which is irreversible enamel decalcification. To evaluate the effectiveness of different orthodontic adhesives for bonding. Electronic databases: the Cochrane Oral Health Group's Trials Register, the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE and EMBASE. Date of most recent searches: August 2002 (CENTRAL) (The Cochrane Library Issue 2, 2002). Trials were selected if they met the following criteria: randomised controlled trials (RCTs) and controlled clinical trials (CCTs) comparing two different adhesive groups. Participants were patients with fixed orthodontic appliances. The interventions were adhesives that bonded stainless steel brackets to all teeth except the molars. The primary outcome was debond or bracket failure. Data were recorded on decalcification as a secondary outcome, if present. Information regarding methods, participants, interventions, outcome measures and results were extracted in duplicate by pairs of reviewers (Nicky Mandall (NM) and Rye Mattick (CRM); Declan Millett (DTM) and Joy Hickman (JH2)). Since the data were not presented in a form that was amenable to meta-analysis, the results of the review are presented in narrative form only. Three trials satisfied the inclusion criteria. A chemical cured composite was compared with a light cure composite (one trial), a conventional glass ionomer cement (one trial) and a polyacid-modified resin composite (compomer) (one trial). The quality of the trial reports was generally poor. It is difficult to draw any conclusions from this review, however, suggestions are made for methods of improving future research involving

  3. Children's exposure to violent video games and desensitization to violence.

    Science.gov (United States)

    Funk, Jeanne B

    2005-07-01

    Desensitization to violence is cited frequently as being an outcome of exposure to media violence and a condition that contributes to increased aggression. This article initiates the development of a conceptual model for describing possible relationships among violent video games, brain function, and desensitization by using empathy and attitudes toward violence as proxy measures of desensitization. More work is needed to understand how specific game content may affect brain activity, how brain development may be affected by heavy play at young ages, and how personality and lifestyle variables may moderate game influence. Given the current state of knowledge, recommendations are made for clinicians to help parents monitor and limit exposure to violent video games and encourage critical thinking about media violence.

  4. Influence of optical properties of esthetic brackets (color, translucence, and fluorescence) on visual perception.

    Science.gov (United States)

    Lopes Filho, Hibernon; Maia, Lúcio E G; Araújo, Marcus Vinicius A; Ruellas, Antônio Carlos O

    2012-04-01

    The aims of this study were to evaluate the optical properties of esthetic brackets and determine their influence on visual perception. Eighty esthetic brackets of 16 commercial brands were tested. The color and translucency of the brackets, as well as the color of the maxillary central incisors of 40 subjects, were measured with a spectrophotometer. The fluorescence of the brackets was determined by duly calibrated appraisers. The color differences between the brands of brackets and the teeth were calculated. Data were analyzed by using 1-way analysis of variance; the Scheffé multiple comparison test was used to establish the difference between brands of brackets, (α = 0.05). The color parameters L ∗ a ∗ b ∗ of nontranslucent brackets ranged from 49.4 to 86.0, -1.6 to 3.0, and 1.9 to 14.6, respectively. The direct transmission of light ranged from 0.0% to 38.8% transmittance. No bracket showed fluorescence. The color and translucency, as well as the color difference, of the brackets were influenced by brand (P perception; translucent brackets and the nontranslucent InVu (TP Orthodontics, LaPorte, Ind) brackets were less visually perceptible. Copyright © 2012 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  5. Laser Guided Automated Calibrating System for Accurate Bracket ...

    African Journals Online (AJOL)

    Background: The basic premise of preadjusted bracket system is accurate bracket positioning. ... using MATLAB ver. 7 software (The MathWorks Inc.). These images are in the form of matrices of size 640 × 480. 650 nm (red light) type III diode laser is used as ... motion control and Pitch, Yaw, Roll degrees of freedom (DOF).

  6. Study of force loss due to friction comparing two ceramic brackets during sliding tooth movement.

    Science.gov (United States)

    AlSubaie, Mai; Talic, Nabeel; Khawatmi, Said; Alobeid, Ahmad; Bourauel, Christoph; El-Bialy, Tarek

    2016-09-01

    To compare the percentage of force loss generated during canine sliding movements in newly introduced ceramic brackets with metal brackets. Two types of ceramic brackets, namely polycrystalline alumina (PCA) ceramic brackets (Clarity Advanced) and monocrystalline alumina (MCA) ceramic brackets (Inspire Ice) were compared with stainless steel (SS) brackets (Victory Series). All bracket groups (n = 5 each) were for the maxillary canines and had a 0.018-inch slot size. The brackets were mounted on an Orthodontic Measurement and Simulation System (OMSS) to simulate the canine retraction movement into the first premolar extraction space. Using elastic ligatures, 0.016 × 0.022″ (0.40 × 0.56 mm) stainless steel archwires were ligated onto the brackets. Retraction force was applied via a nickel-titanium coil spring with a nearly constant force of approximately 1 N. The OMSS measured the percentage of force loss over the retraction path by referring to the difference between the applied retraction force and actual force acting on each bracket. Between group comparisons were done with one-way analysis of variance. The metal brackets revealed the lowest percentage of force loss due to friction, followed by the PCA and MCA ceramic bracket groups (67 ± 4, 68 ± 7, and 76 ± 3 %, respectively). There was no significant difference between SS and PCA brackets (p = 0.97), but we did observe significant differences between metal and MCA brackets (p = 0.03) and between PCA and MCA ceramic brackets (p = 0.04). PCA ceramic brackets, whose slot surface is covered with an yttria-stabilized zirconia-based coating exhibited frictional properties similar to those of metal brackets. Frictional resistance resulted in an over 60 % loss of the applied force due to the use of elastic ligatures.

  7. On covariant Poisson brackets in classical field theory

    International Nuclear Information System (INIS)

    Forger, Michael; Salles, Mário O.

    2015-01-01

    How to give a natural geometric definition of a covariant Poisson bracket in classical field theory has for a long time been an open problem—as testified by the extensive literature on “multisymplectic Poisson brackets,” together with the fact that all these proposals suffer from serious defects. On the other hand, the functional approach does provide a good candidate which has come to be known as the Peierls–De Witt bracket and whose construction in a geometrical setting is now well understood. Here, we show how the basic “multisymplectic Poisson bracket” already proposed in the 1970s can be derived from the Peierls–De Witt bracket, applied to a special class of functionals. This relation allows to trace back most (if not all) of the problems encountered in the past to ambiguities (the relation between differential forms on multiphase space and the functionals they define is not one-to-one) and also to the fact that this class of functionals does not form a Poisson subalgebra

  8. On covariant Poisson brackets in classical field theory

    Energy Technology Data Exchange (ETDEWEB)

    Forger, Michael [Instituto de Matemática e Estatística, Universidade de São Paulo, Caixa Postal 66281, BR–05315-970 São Paulo, SP (Brazil); Salles, Mário O. [Instituto de Matemática e Estatística, Universidade de São Paulo, Caixa Postal 66281, BR–05315-970 São Paulo, SP (Brazil); Centro de Ciências Exatas e da Terra, Universidade Federal do Rio Grande do Norte, Campus Universitário – Lagoa Nova, BR–59078-970 Natal, RN (Brazil)

    2015-10-15

    How to give a natural geometric definition of a covariant Poisson bracket in classical field theory has for a long time been an open problem—as testified by the extensive literature on “multisymplectic Poisson brackets,” together with the fact that all these proposals suffer from serious defects. On the other hand, the functional approach does provide a good candidate which has come to be known as the Peierls–De Witt bracket and whose construction in a geometrical setting is now well understood. Here, we show how the basic “multisymplectic Poisson bracket” already proposed in the 1970s can be derived from the Peierls–De Witt bracket, applied to a special class of functionals. This relation allows to trace back most (if not all) of the problems encountered in the past to ambiguities (the relation between differential forms on multiphase space and the functionals they define is not one-to-one) and also to the fact that this class of functionals does not form a Poisson subalgebra.

  9. Infectious complications in living-donor kidney transplant recipients undergoing multi-modal desensitization.

    Science.gov (United States)

    Turza, Kristin C; Shafique, Michael; Lobo, Peter I; Sawyer, Robert G; Keith, Douglas S; Brayman, Kenneth L; Agarwal, Avinash

    2014-06-01

    Pre-existing humoral barriers challenge the transplantation of living donor kidneys (LDK) into highly sensitized ABO- and human leukocyte antigen (HLA)-incompatible recipients. Conditioning these LDK recipients' immune systems is required before they undergo transplantation. We hypothesized that medical desensitization would yield higher post-transplantation rates of infection. We conducted a study in which matched controls consisting of non-desensitized (NDS) LDK recipients were compared with desensitized (DS) receipients. Pre-transplantation desensitization included treatment with rituximab and mycophenolate mofetil followed by intravenous immunoglobulin (IVIg) and plasmapheresis. All participants in the study underwent induction therapy and maintenance immunosuppression. Primary outcomes included infection (opportunistic, local, systemic) within 12 mo after transplantation. Twenty-five patients underwent desensitization and LDK transplantation. Graft survival in the DS and NDS groups of patients was 96% and 98%, respectively. The mean 3- and 12-mo serum creatinine concentrations in the DS and NDS groups were 1.1±0.2 mg/dL and 1.2±0.3 mg/dL and 0.95±0.4 mg/dL and 0.73±0.8 mg/dL (p=0.3 and p=0.01), respectively. Thirty-six percent of the patients in the DS group had one or more infections, vs. 28% of those in the NDS group (p=0.1). No difference was observed in the frequency of opportunistic or systemic infections in the two groups. Local infections were statistically significantly more frequent in the DS group (60% vs. 30%, respectively; p=0.02). Pre-operative desensitization in highly sensitized LDK recipients is followed by a similar incidence of opportunistic and systemic infections as in NDS patients. Local infections were significantly more frequent in the DS than in the NDS patients in the study. With careful monitoring of infectious complications, pre-transplant desensitization permits LDK transplantation into highly sensitized patients.

  10. Torque expression of 0.018 and 0.022 inch conventional brackets

    NARCIS (Netherlands)

    Sifakakis, I.; Pandis, N.; Makou, M.; Eliades, T.; Katsaros, C.; Bourauel, C.

    2013-01-01

    The aim of this study was to assess the effect of the moments generated with low- and high-torque brackets. Four different bracket prescription-slot combinations of the same bracket type (Mini Diamond(R) Twin) were evaluated: high-torque 0.018 and 0.022 inch and low-torque 0.018 and 0.022 inch.

  11. In vitro physical, chemical, and biological evaluation of commercially available metal orthodontic brackets.

    Science.gov (United States)

    Kim, Joo Hyoung; Cha, Jung Yul; Hwang, Chung Ju

    2012-12-01

    This in vitro study was undertaken to evaluate the physical, chemical, and biological properties of commercially available metal orthodontic brackets in South Korea, because national standards for these products are lacking. FOUR BRACKET BRANDS WERE TESTED FOR DIMENSIONAL ACCURACY, (MANUFACTURING ERRORS IN ANGULATION AND TORQUE), CYTOTOXICITY, COMPOSITION, ELUTION, AND CORROSION: Archist (Daeseung Medical), Victory (3M Unitek), Kosaka (Tomy), and Confidence (Shinye Odontology Materials). The tested rackets showed no significant differences in manufacturing errors in angulation, but Confidence brackets showed a significant difference in manufacturing errors in torque. None of the brackets were cytotoxic to mouse fibroblasts. The metal ion components did not show a regular increasing or decreasing trend of elution over time, but the volume of the total eluted metal ions increased: Archist brackets had the maximal Cr elution and Confidence brackets appeared to have the largest volume of total eluted metal ions because of excessive Ni elution. Confidence brackets showed the lowest corrosion resistance during potentiodynamic polarization. The results of this study could potentially be applied in establishing national standards for metal orthodontic brackets and in evaluating commercially available products.

  12. Influence of Preadjusted Bracket Shape and Positioning Reference on Angulation of Upper Central Incisor.

    Science.gov (United States)

    Topolski, Francielle; de O Accorsi, Mauricio A; Trevisi, Hugo J; Cuoghi, Osmar A; Moresca, Ricardo

    2016-10-01

    To verify the influence of different bracket shapes and placement references according to Andrews and MBT systems on the expression of angulation in upper central incisors (UCI). Bracket positioning and mesiodistal dental movement simulations were performed and the angulations produced in the dental crown were evaluated, based on computed tomography scan images of 30 UCI and AutoCAD software analysis. Rectangular (Andrews) and rhomboid (MBT) brackets were placed according to the references recommended by Andrews and MBT systems - long axis of the clinical crown (LACC) and incisal edge (IE) respectively. Data showed that the use of LACC as reference for bracket positioning produced 5° and 4° UCI angulations in Andrews and MBT brackets respectively. The use of IE produced a 1.2° mean angulation in UCI for both brackets. When the LACC was used as reference for bracket positioning, the UCI crown angulation corresponded to the angulation built into the brackets, regardless of shape, while the use of IE resulted in natural crown angulation, regardless of bracket shape. This research contributes to guide the orthodontist in relation to the different treatment techniques based on the use of preadjusted brackets.

  13. Evaluation of shear bond strength of metal bracket to enamel after application of primers over bracket base-an in vitro study

    Directory of Open Access Journals (Sweden)

    Firuzbakht MM

    2011-04-01

    Full Text Available "nBackground and Aims: The aim of this study was to evaluate the effect of application of two types of primers over bracket bases on the shear bond strength (SBS and mode of bond failure."nMaterials and Methods: In this study, 75 human premolar teeth were divided into three equal groups. In group 1 (control, after surface preparation of enamel by conventional method (acid etching+primer brackets were bonded with Transbond XT composite. In group 2 (TX, brackets were bonded to enamel same as the first group but Transbond XT primer were used on bracket bases before placement of composite. In group 3 (PL, Transbond plus primer was applied on bracket bases before placement of composite. After 24 h, the SBS test was performed by universal testing machine at crosshead speed of 0.5 mm/min. Then, adhesive remnant index (ARI scores and percentage of cohesive fracture were determined using stereomicroscopy. SBS data were analyzed by one-way ANOVA and Duncan tests. Kruskal-Wallis and Mann-Whitney tests were used to analyze ARI and cohesive fracture results."nResults: There was significant difference in SBS values among the groups (P<0.001. The highest SBS was shown in TX group and the lowest was seen in PL group. There was no significant difference between control and TX groups in ARI scores (P=0.199. No significant difference was found in cohesive fracture values between the groups (P=0.093. Both the control and TX groups showed significant difference in ARI scores and cohesive fracture compared with the PL group in all of the comparisons (P<0.001."nConclusion: Application of Transbond XT primer over bracket base affects the bond strength and failure mode. Transbond XT primer increased the bond strength but Transbond plus primer decreased it.

  14. Desensitization: Overcoming the Immunologic Barriers to Transplantation

    Science.gov (United States)

    Choi, Jua; Vo, Ashley; Peng, Alice; Jordan, Stanley C.

    2017-01-01

    HLA (Human Leucocyte Antigen) sensitization is a significant barrier to successful kidney transplantation. It often translates into difficult crossmatch before transplant and increased risk of acute and chronic antibody mediated rejection after transplant. Over the last decade, several immunomodulatory therapies have emerged allowing for increased access to kidney transplantation for the immunologically disadvantaged group of HLA sensitized end stage kidney disease patients. These include IgG inactivating agents, anti-cytokine antibodies, costimulatory molecule blockers, complement inhibitors, and agents targeting plasma cells. In this review, we discuss currently available agents for desensitization and provide a brief analysis of data on novel biologics, which will likely improve desensitization outcomes, and have potential implications in treatment of antibody mediated rejection. PMID:28127571

  15. Desensitization of Children to Television Violence

    Science.gov (United States)

    Cline, Victor B.; And Others

    1973-01-01

    To find if children do become desensitized to violence, a test for a measurable physiological difference in emotional response to filmed violence was administered to children who are high exposure and low exposure television viewers. (Author/KM)

  16. In vitro assessment of competency for different lingual brackets in sliding mechanics.

    Science.gov (United States)

    Lalithapriya, S; Kumaran, N Kurunji; Rajasigamani, K

    2015-01-01

    To determine the static frictional resistance of different lingual brackets at different second order angulations when coupled with stainless steel (SS) archwire in dry and wet conditions. Using a modified jig, frictional resistance was evaluated under different conditions for a total of 270 upper premolar lingual brackets (0.018″ × 0.025″ - conventional - 7(th) generation and STb, self-ligating - evolution) with no in-built tip or torque together with 0.016″ × 0.022″ straight length SS archwires. For conventional brackets, the archwire was secured with 0.008″ preformed SS short ligature ties. One way analysis of variance with Tukey HSD as post-hoc test was applied for degree wise and bracket wise comparison within dry condition and wet condition. For pair wise comparison Student's t-test was used. Under both conditions the static frictional resistance is significantly higher for self-ligating brackets at 0°, while at 5° and 10° it is higher for 7(th) generation brackets. Statistically, significant difference does not exist at 0° between conventional brackets and the same was found at 5° and 10° between STb and self-ligating brackets. With an increase in second order angulations, all the evaluated samples exhibited an increased frictional value. Wet condition samples obtained a higher value than their corresponding dry condition. The self-ligating bracket evaluated in this in vitro study is not beneficial in reducing friction during en-mass retraction due to its interactive clip type.

  17. Is laser conditioning a valid alternative to conventional etching for aesthetic brackets?

    Science.gov (United States)

    Sfondrini, M F; Calderoni, G; Vitale, M C; Gandini, P; Scribante, A

    2018-03-01

    ER:Yag lasers have been described as a more conservative alternative to conventional acid-etching enamel conditioning technique, when bonding conventional metallic orthodontic brackets. Since the use of aesthetic orthodontic brackets is constantly increasing, the purpose of the present report has been to test laser conditioning with different aesthetic brackets. Study Design: Five different aesthetic brackets (microfilled copolymer, glass fiber, sapphire, polyoxymethylene and sintered ceramic) were tested for shear bond strength and Adhesive Remnant Index scores using two different enamel conditioning techniques (acid etching and ER:Yag laser application). Two hundred bovine incisors were extracted, cleaned and embedded in resin. Specimens were then divided into 10 groups with random tables. Half of the specimens were conditioned with conventional orthophosphoric acid gel, the other half with ER:Yag laser. Different aesthetic brackets (microfilled copolymer, glass fiber, sapphire, polyoxymethylene and sintered ceramic) were then bonded to the teeth. Subsequently all groups were tested in shear mode with a Universal Testing Machine. Shear bond strength values and adhesive remnant index scores were recorded. Statistical analysis was performed. When considering conventional acid etching technique, sapphire, polyoxymethylene and sintered ceramic brackets exhibited the highest SBS values. Lowest values were reported for microfilled copolymer and glass fiber appliances. A significant decrease in SBS values after laser conditioning was reported for sapphire, polyoxymethylene and sintered ceramic brackets, whereas no significant difference was reported for microfilled copolymer and glass fiber brackets. Significant differences in ARI scores were also reported. Laser etching can significantly reduce bonding efficacy of sapphire, polyoxymethylene and sintered ceramic brackets.

  18. An in vitro comparison of nickel and chromium release from brackets

    Directory of Open Access Journals (Sweden)

    Ana Cristina Soares Santos Haddad

    2009-12-01

    Full Text Available This study aimed at comparing amounts of nickel (Ni and chromium (Cr released from brackets from different manufacturers in simulated oral environments. 280 brackets were equally divided into 7 groups according to manufacturer. 6 groups of brackets were stainless steel, and 1 group of brackets was made of a cobalt-chromium alloy with low Ni content (0.5%. International standard ISO 10271/2001 was applied to provide test methods. Each bracket was immersed in 0.5 ml of synthetic saliva (SS or artificial plaque fluid (PF over a period of 28 days at 37ºC. Solutions were replaced every 7 days, and were analyzed by spectrometry. The Kruskal-Wallis test was applied. Amounts of Ni release in SS (µg L-1 per week varied between groups from "bellow detection limits" to 694, and from 49 to 5,948.5 in PF. The group of brackets made of cobalt-chromium alloy, with the least nickel content, did not release the least amounts of Ni. Amounts of Cr detected in SS and in PF (µg L-1 per week were from 1 to 10.4 and from 50.5 to 8,225, respectively. It was therefore concluded that brackets from different manufacturers present different corrosion behavior. Further studies are necessary to determine clinical implications of the findings.

  19. Desensitization of Fire Bell Phobia

    Science.gov (United States)

    O'Reilly, Patricia P.

    1971-01-01

    This case study presents an example of how one school psychologist helped a child and an entire class solve a problem. Although the techniques used are not unique to school psychological practice, the problems presented by their use are. The procedure consisted of a desensitization process lasting ten weeks. (Author)

  20. Galvanic Corrosion among Different Combination of Orthodontic Archwires and Stainless Steel Brackets

    Directory of Open Access Journals (Sweden)

    Farzin Heravi

    2014-06-01

    Full Text Available Introduction: The aim of this study was to assess the galvanic behavior of different bracket and archwire combinations that are commonly used in orthodontic treatments. Methods: Three types of orthodontic archwires with a diameter of 0.016×0.022 inch and 80 standard edgewise maxillary central incisor brackets were selected. Three groups consisted of different wire-bracket couples and one group was just brackets as a control group. Each group had five samples. Four brackets were then connected to each wire by elastic bands made from electrochemically neutral material. The samples were immersed into capped containers of Fusayama-Meyer artificial saliva. After six weeks, the released nickel ions were quantified via ion absorption technique. The mean and the standard deviation of all four groups were calculated and the data were compared together with Kruskal-Wallis non-parametric statistical test. Results: The highest concentration of released nickel ions was for bracket+ steel archwire and the least for the bracket without archwire. Conclusion: There were not significant differences among experimental groups, so it could be concluded that galvanic corrosion would not be a serious consideration through orthodontic treatment.  

  1. Analysis of Shear Bond Strength and Morphology of Er:YAG Laser-Recycled Ceramic Orthodontic Brackets.

    Science.gov (United States)

    Han, Ruo-qiao; Yang, Kai; Ji, Ling-fei; Ling, Chen

    2016-01-01

    The aim of this study was to compare the recycling of deboned ceramic brackets via an Er:YAG laser or via the traditional chairside processing methods of flaming and sandblasting; shear bond strength and morphological changes were evaluated in recycled brackets versus new brackets. 3M Clarity Self-Ligating Ceramic Brackets with a microcrystalline base were divided into groups subjected to flaming, sandblasting, or exposure to an Er:YAG laser. New ceramic brackets served as a control group. Shear bond strengths were determined with an Electroforce test machine and tested for statistical significance through analysis of variance. Morphological examinations of the recycled ceramic bracket bases were conducted with scanning electron microscopy and confocal laser scanning microscopy. Residue on the bracket base was analyzed with Raman spectroscopy. Faded, dark adhesive was left on recycled bracket bases processed via flaming. Adhesive was thoroughly removed by both sandblasting and exposure to an Er:YAG laser. Compared with new brackets, shear bond strength was lower after sandblasting (p bracket. Er:YAG lasers effectively remove adhesive from the bases of ceramic brackets without damaging them; thus, this method may be preferred over other recycling methods.

  2. Effects of recycling and bonding agent application on bond strength of stainless steel orthodontic brackets

    OpenAIRE

    Bahnasi, Faisal I.; Abd-Rahman, Aida NA.; Abu-Hassan, Mohame I.

    2013-01-01

    Objectives: 1) to assess different methods of recycling orthodontic brackets, 2) to evaluate Shear Bond Strength (SBS) of (a) new, (b) recycled and (c) repeated recycled stainless steel brackets (i) with and (ii) without bracket base primer. Study Design: A total of 180 extracted human premolar teeth and 180 premolar stainless steel brackets were used. One hundred teeth and 100 brackets were divided into five groups of 20-teeth each. Four methods of recycling orthodontic brackets were used in...

  3. Self-ligating vs conventional twin brackets during en-masse space closure with sliding mechanics.

    Science.gov (United States)

    Miles, Peter G

    2007-08-01

    The aim of this study was to compare the rate of en-masse space closure with sliding mechanics between passive self-ligating SmartClip brackets (3M Unitek, Monrovia, Calif) and conventional twin brackets ligated with stainless steel ligatures. Nineteen patients including 20 arches participated in this prospective trial with 0.018-in slot brackets. All patients had first premolar extractions in at least 1 arch, with the second premolar and the first molar distal to the extraction site bonded with SmartClip brackets on 1 side and conventional twin brackets on the other. The sides were alternated with each consecutive patient. Space closure was achieved on 0.016 x 0.022-in stainless steel wires with nickel-titanium coil springs activated 6 to 9 mm. The patients were recalled every 5 weeks until 1 side had closed. The distances from the mesial aspect of the canine bracket to the distal aspect of the first molar bracket were recorded before and after space closure, and an average rate of space closure per month was calculated. Thirteen patients completed the trial (14 arches); the median rates of tooth movement for the SmartClip bracket side (1.1 mm per month) and the conventional twin bracket side (1.2 mm per month) were not significantly different (P = .86). There was no significant difference in the rate of en-masse space closure between passive SmartClip brackets and conventional twin brackets tied with stainless steel ligatures.

  4. [Experience of rapid drug desensitization therapy in the treatment of mycobacterial disease].

    Science.gov (United States)

    Sasaki, Yuka; Kurashima, Atsuyuki; Morimoto, Kozo; Okumura, Masao; Watanabe, Masato; Yoshiyama, Takashi; Ogata, Hideo; Gotoh, Hajime; Kudoh, Shoji; Suzuki, Hiroaki

    2014-11-01

    Drugs for tuberculosis and non-tuberculosis mycobacterial diseases are limited. In particular, no new drugs for non-tuberculosis mycobacterial disease have been developed in recent years. Antimycobacterial drugs have many adverse reactions, for which drug desensitization therapy has been used. Rapid drug desensitization (RDD) therapy, including antituberculosis drugs and clarithromycin, has been implemented in many regions in Europe and the United States. We investigated the validity of RDD therapy in Japan. We report our experience with RDD therapy in 13 patients who developed severe drug allergy to antimycobacterial treatment. The desensitization protocol reported by Holland and Cernandas was adapted. The underlying diseases were 7 cases of pulmonary Mycobacterium avium complex disease and 6 cases of pulmonary tuberculosis. Isoniazid was readministered in 2 (100%) of 2 patients; rifampicin, in 8 (67.7%) of 12 patients; ethambutol, in 4 (67.7%) of 6 patients; and clarithromycin, in 2 (100%) of 2 patients. In Japan, the desensitization therapy recommended by the Treatment Committee of the Japanese Society for Tuberculosis have been implemented generally. We think RDD therapy is effective and safe as the other desensitization therapy. We will continue to investigate the efficiency of RDD therapy in patients who had discontinued antimycobacterial treatment because of the drug allergic reaction.

  5. Desensitization of γ-aminobutyric acid receptor from rat brain: two distinguishable receptors on the same membrane

    International Nuclear Information System (INIS)

    Cash, D.J.; Subbarao, K.

    1987-01-01

    Transmembrane chloride flux mediated by γ-aminobutyric acid (GABA) receptor can be measured with a mammalian brain homogenate preparation containing sealed membrane vesicles. The preparation can be mixed rapidly with solutions of defined composition. Influx of 36 Cl - tracer initiated by mixing with GABA was rapidly terminated by mixing with bicuculline methiodide. The decrease in the isotope influx measurement due to prior incubation of the vesicle preparation with GABA, which increased with preincubation time and GABA concentration, was attributed to desensitization of the GABA receptor. By varying the time of preincubation with GABA between 10 ms and 50 s with quench-flow technique, the desensitization rates could be measured over their whole time course independently of the chloride ion flux rate. Most of the receptor activity decreased in a fast phase of desensitization complete in 200 ms at saturation with GABA. Remaining activity was desensitized in a few seconds. These two phases of desensitization were each kinetically first order and were shown to correspond with two distinguishable GABA receptors on the same membrane. The receptor activities could be estimated, and the faster desensitizing receptor was the predominant one, giving on average ca. 80% of the total activity. The half-response concentrations were similar, 150 and 114 μM for the major and minor receptors, respectively. The dependence on GABA concentration indicated that desensitization is mediated by two GABA binding sites. The fast desensitization rate was approximately 20-fold faster than previously reported rates while the slower desensitization rate was slightly faster than previously reported rates

  6. Friction behavior of self-ligating and conventional brackets with different ligature systems.

    Science.gov (United States)

    Szczupakowski, Alexandra; Reimann, Susanne; Dirk, Cornelius; Keilig, Ludger; Weber, Anna; Jäger, Andreas; Bourauel, Christoph

    2016-07-01

    Self-ligating brackets are widely believed to offer better clinical efficiency and, in particular, less friction. Thus, the goal of this in vitro investigation was to assess the friction behavior of different bracket/archwire/ligature combinations during simulated canine retraction. An important aspect of this work was to determine whether conventional bracket systems behave differently in passive or active self-ligating brackets used with a Slide™ ligature, an elastic ligature, or a steel ligature. Three conventional (Contour, Class One; Discovery(®), Dentaurum; Mystique MB, GAC) and six self-ligating (Carriere SL, Class One; Clarity™ SL, 3M Unitek; Damon3, Ormco; In-Ovation(®) C, GAC; Speed Appliance, Speed System™; QuicKlear(®), Forestadent(®)) bracket systems were analyzed. All brackets featured a 0.022″ slot (0.56 mm). Each conventional system was tested with a steel ligature (0.25 mm; Remanium(®), Dentaurum), an elastic ligature (1.3 mm in diameter; Dentalastics, Dentaurum), and a modified elastic ligature (Slide™; Leone(®)). Each combination was used with four archwires, including rectangular stainless steel (0.46 × 0.64 mm, 0.018 × 0.025″, Dentaurum), rectangular nickel-titanium with Teflon coating (0.46 × 0.64 mm, 0.018 × 0.025″, Forestadent(®)), round coaxial nickel-titanium (0.46 mm, 0.018″, Speed), and half-round/half-square (D-profile) stainless steel (0.46 mm, 0.018″, Speed). In the orthodontic measurement and simulation system (OMSS), retraction of a canine was simulated on a Frasaco model replicated in resin. Based on the force systems, the respective friction values were determined. For each combination of materials, five brackets of the same type were tested and five single measurements performed. Friction values were found to vary distinctly with the different combinations, modifiers being the ligature systems and the archwire types. Any significant friction differences between the steel-ligated, Slide

  7. Sequential allergen desensitization of basophils is non-specific and may involve p38 MAPK.

    Science.gov (United States)

    Witting Christensen, S K; Kortekaas Krohn, I; Thuraiaiyah, J; Skjold, T; Schmid, J M; Hoffmann, H J H

    2014-10-01

    Sequential allergen desensitization provides temporary tolerance for allergic patients. We adapted a clinical protocol to desensitize human blood basophils ex vivo and investigated the mechanism and allergen specificity. We included 28 adult, grass allergic subjects. The optimal, activating allergen concentration was determined by measuring activated CD63(+) CD193(+) SS(Low) basophils in a basophil activation test with 8 log-dilutions of grass allergen. Basophils in whole blood were desensitized by incubation with twofold to 2.5-fold increasing allergen doses in 10 steps starting at 1 : 1000 of the optimal dose. Involvement of p38 mitogen-activated protein kinase (MAPK) was assessed after 3 min of allergen stimulation (n = 7). Allergen specificity was investigated by desensitizing cells from multi-allergic subjects with grass allergen and challenging with optimal doses of grass, birch, recombinant house dust mite (rDer p2) allergen or anti-IgE (n = 10). Desensitization reduced the fraction of blood basophils responding to challenge with an optimal allergen dose from a median (IQR) 81.0% (66.3-88.8) to 35.4% (19.8-47.1, P desensitized with grass allergen. Challenge with grass allergen resulted in 39.6% activation (15.8-58.3). An unrelated challenge (birch, rDer p2 or anti-IgE) resulted in 53.4% activation (30.8-66.8, P = 0.16 compared with grass). Desensitization reduced p38 MAPK phosphorylation from a median 48.1% (15.6-92.8) to 26.1% (7.4-71.2, P = 0.047) and correlated with decrease in CD63 upregulation (n = 7, r > 0.79, P Desensitization attenuated basophil response rapidly and non-specifically at a stage before p38 MAPK phosphorylation. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. An Aversion-Desensitization Treatment for Alcoholism

    Science.gov (United States)

    Primo, Richard V.; And Others

    1972-01-01

    A six-to nine-month interview follow-up showed that five of the seven traceable Ss given the interpersonal aversion-systematic desensitization treatment had been abstinent, compared with only one of seven treated by the interpersonal aversion-control procedure. (Author)

  9. Subthreshold Desensitization of Human Basophils Re-capitulates the Loss of syk and FcεRI expression Characterized by Other Methods of Desensitization

    Science.gov (United States)

    MacGlashan, Donald

    2012-01-01

    Background Clinical desensitization of patients to drugs involves progressive exposure to escalating doses of drug over a period of 24 hours. In prior studies, this method was recapitulated in vitro to also demonstrate loss of mast cell or basophil responsiveness. However, most signaling studies of human basophils have identified changes in signaling by using other methods of inducing cellular desensitization. Objective This study examined two well-described endpoints of basophil desensitization, loss of syk or FcεRI expression, under conditions of subthreshold desensitization. Methods The loss of FceRI and syk was examined in human basophils. Results It was shown that both loss of syk and FcεRI/IgE occurred during an escalating series of stimulation (anti-IgE Ab) and that expression loss occurred despite the presence of little histamine release. If basophils were first cultured for 3 days in 10 ng/ml IL-3, the concentration-dependence of histamine release shifted to 100 fold lower concentrations of stimulus. However, loss of syk did not show any change in its EC50 while loss of FcεRI also shifted 100 fold. From the perspective of early signal element activation, the marked shift in the EC50 for histamine release was not accompanied by similar shifts in the EC50s for several signaling elements. The EC50s for phospho-Src, phospho-SHIP1, phospho-Syk, or phospho-Cbl did not change while the EC50s for phospho-Erk and the cytosolic calcium response did shift 100 fold. Conclusions These studies show that under normal conditions, subthreshold desensitization leads to loss of two critical signaling molecules (FcεRI and syk) but under at least one condition, treatment with IL-3, it is possible to markedly blunt the loss of syk, but not FcεRI, while executing a proper subthreshold titration. These data also suggest that IL-3 modifies only the sensitivity of signaling elements that are downstream of syk activation. PMID:22702505

  10. Nd:YAG Laser-aided ceramic brackets debonding: Effects on shear bond strength and enamel surface

    Science.gov (United States)

    Han, Xianglong; Liu, Xiaolin; Bai, Ding; Meng, Yao; Huang, Lan

    2008-11-01

    In order to evaluate the efficiency of Nd:YAG laser-aided ceramic brackets debonding technique, both ceramic brackets and metallic brackets were bonded with orthodontic adhesive to 30 freshly extracted premolars. The specimens were divided into three groups, 10 in each, according to the brackets employed and the debonding techniques used: (1) metallic brackets with shear debonding force, (2) ceramic brackets with shear debonding force, and (3) ceramic brackets with Nd:YAG laser irradiation. The result showed that laser irradiation could diminish shear bond strength (SBS) significantly and produce the most desired ARI scores. Moreover, scanning electron microscopy investigation displayed that laser-aided technique induced little enamel scratch or loss. It was concluded that Nd:YAG laser could facilitate the debonding of ceramic brackets and diminish the amount of remnant adhesive without damaging enamel structure.

  11. Nd:YAG Laser-aided ceramic brackets debonding: Effects on shear bond strength and enamel surface

    International Nuclear Information System (INIS)

    Han Xianglong; Liu Xiaolin; Bai Ding; Meng Yao; Huang Lan

    2008-01-01

    In order to evaluate the efficiency of Nd:YAG laser-aided ceramic brackets debonding technique, both ceramic brackets and metallic brackets were bonded with orthodontic adhesive to 30 freshly extracted premolars. The specimens were divided into three groups, 10 in each, according to the brackets employed and the debonding techniques used: (1) metallic brackets with shear debonding force, (2) ceramic brackets with shear debonding force, and (3) ceramic brackets with Nd:YAG laser irradiation. The result showed that laser irradiation could diminish shear bond strength (SBS) significantly and produce the most desired ARI scores. Moreover, scanning electron microscopy investigation displayed that laser-aided technique induced little enamel scratch or loss. It was concluded that Nd:YAG laser could facilitate the debonding of ceramic brackets and diminish the amount of remnant adhesive without damaging enamel structure

  12. Nd:YAG Laser-aided ceramic brackets debonding: Effects on shear bond strength and enamel surface

    Energy Technology Data Exchange (ETDEWEB)

    Han Xianglong [State Key Laboratory of Oral Diseases, Sichuan University, Chengdu 610041 (China); Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041 (China); Liu Xiaolin [Department of Orthodontics, Stomatology Hospital, Dalian University, Dalian 116021 (China); Bai Ding [State Key Laboratory of Oral Diseases, Sichuan University, Chengdu 610041 (China); Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041 (China)], E-mail: baiding88@hotmail.com; Meng Yao; Huang Lan [Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041 (China)

    2008-11-15

    In order to evaluate the efficiency of Nd:YAG laser-aided ceramic brackets debonding technique, both ceramic brackets and metallic brackets were bonded with orthodontic adhesive to 30 freshly extracted premolars. The specimens were divided into three groups, 10 in each, according to the brackets employed and the debonding techniques used: (1) metallic brackets with shear debonding force, (2) ceramic brackets with shear debonding force, and (3) ceramic brackets with Nd:YAG laser irradiation. The result showed that laser irradiation could diminish shear bond strength (SBS) significantly and produce the most desired ARI scores. Moreover, scanning electron microscopy investigation displayed that laser-aided technique induced little enamel scratch or loss. It was concluded that Nd:YAG laser could facilitate the debonding of ceramic brackets and diminish the amount of remnant adhesive without damaging enamel structure.

  13. Rate of Homologous Desensitization and Internalization of the GLP-1 Receptor.

    Science.gov (United States)

    Shaaban, Ghina; Oriowo, Mabayoje; Al-Sabah, Suleiman

    2016-12-26

    The glucagon-like peptide-1 receptor (GLP-1R) is an important target in the treatment of type 2 diabetes mellitus. The aim of this study was to compare the rate of agonist stimulated desensitization and internalization of GLP-1R. To this end, an N-terminally myc-tagged GLP-1R was stably expressed in HEK-293 cells. Homologous desensitization was assessed by measuring the cAMP response to agonist stimulation following pre-incubation with agonist for up to 120 min. Receptor internalization was monitored using an indirect ELISA-based method and confocal microscopy. Pre-incubation with GLP-1 resulted in a time-dependent loss of response to a second stimulation. Washing cells following pre-incubation failed to bring cAMP levels back to basal. Taking this into account, two desensitization rates were calculated: "apparent" (t 1/2 = 19.27 min) and "net" (t 1/2 = 2.99 min). Incubation of cells with GLP-1 also resulted in a time-dependent loss of receptor cell surface expression (t 1/2 = 2.05 min). Rapid agonist-stimulated internalization of GLP-1R was confirmed using confocal microscopy. Stimulation of GLP-1R with GLP-1 results in rapid desensitization and internalization of the receptor. Interestingly, the rate of "net" desensitization closely matches the rate of internalization. Our results suggest that agonist-bound GLP-1R continues to generate cAMP after it has been internalized.

  14. Cleansing orthodontic brackets with air-powder polishing: effects on frictional force and degree of debris.

    Science.gov (United States)

    Leite, Brisa Dos Santos; Fagundes, Nathalia Carolina Fernandes; Aragón, Mônica Lídia Castro; Dias, Carmen Gilda Barroso Tavares; Normando, David

    2016-01-01

    Debris buildup on the bracket-wire interface can influence friction. Cleansing brackets with air-powder polishing can affect this process. The aim of this study was to evaluate the frictional force and amount of debris remaining on orthodontic brackets subjected to prophylaxis with air-powder polishing. Frictional force and debris buildup on the surface of 28 premolar brackets were evaluated after orthodontic treatment. In one hemiarch, each bracket was subjected to air-powder polishing (n = 14) for five seconds, while the contralateral hemiarch (n = 14) served as control. Mechanical friction tests were performed and images of the polished bracket surfaces and control surfaces were examined. Wilcoxon test was applied for comparative analysis between hemiarches at p Brackets that had been cleaned with air-powder polishing showed lower friction (median = 1.27 N) when compared to the control surfaces (median = 4.52 N) (p orthodontic brackets with air-powder polishing significantly reduces debris buildup on the bracket surface while decreasing friction levels observed during sliding mechanics.

  15. The Role of Attention-Placebo Influences in the Efficacy of Systematic Desensitization

    Science.gov (United States)

    McReynolds, William T.; And Others

    1973-01-01

    Systematic desensitization was compared with two attention-placebo control treatments--one taken from Paul and one currently devised as an elaborate, highly impressive therapeutic'' experience--and no treatment. It was hypothesized that (a) fear reductions following desensitization would be no greater than those associated with an equally…

  16. Systematic Desensitization as a Method of Teaching a General Anxiety-Reducing Skill

    Science.gov (United States)

    Zemore, Robert

    1975-01-01

    College students were treated with either a standard or modified version of systematic desensitization. Relative to a no-treatment control group, both treatment methods produced significant reductions in both the treated and untreated fears. The implications these findings have for two alternative conceptions of systematic desensitization are…

  17. Topographic and chemical surface modifications to metal brackets after a period in the mouth.

    Science.gov (United States)

    Houb-Dine, Afaf; Bahije, Loubna; Oualalou, Youssef; Benyahia, Hicham; Zaoui, Fatima

    2017-09-01

    In the current state of our knowledge, the effects of corrosion on the performance of orthodontic appliances and on patient health are far from clear. Awareness of these problems has led to a growing demand for nickel-free products. Titanium brackets were recently launched on the market as an alternative to stainless-steel brackets. However, the use of fluorides for caries prevention creates a risk of corrosion of these titanium appliances. The aim of this study is to examine the corrosion of stainless-steel and titanium brackets in clinical orthodontic use, focusing on the impact of fluorine. After approval by the ethics committee and the informed consent of the patients, 30 candidates for multi-bracket treatment were selected on the basis of certain exclusion criteria. The patients were divided into 4 groups: group 1: titanium brackets and fluorine protection; group 2: titanium brackets without fluorine protection; group 3: stainless-steel brackets and fluorine protection; group 4: stainless-steel brackets without fluorine protection. Analysis of the brackets removed after 4months in the mouth, using scanning electron microscopy (SEM) with phase contrast, revealed a difference in the surface topography of the metal brackets and the presence of chromium coating on the surface of the titanium appliances. Copyright © 2017 CEO. Published by Elsevier Masson SAS. All rights reserved.

  18. Oral desensitization to milk: how to choose the starting dose!

    Science.gov (United States)

    Mori, Francesca; Pucci, Neri; Rossi, Maria Elisabetta; de Martino, Maurizio; Azzari, Chiara; Novembre, Elio

    2010-01-01

    Mori F, Pucci N, Rossi ME, de Martino M, Azzari C, Novembre E. Oral desensitization to milk: how to choose the starting dose! Pediatr Allergy Immunol 2010: 21: e450–e453. © 2009 John Wiley & Sons A/S A renewed interest in oral desensitization as treatment for food allergy has been observed in the last few years. We studied a novel method based on the end point skin prick test procedure to establish the starting dose for oral desensitization in a group of 30 children higly allergic to milk. The results (in terms of reactions to the first dose administered) were compared with a group of 20 children allergic to milk as well. Such control group started to swallow the same dose of 0.015 mg/ml of milk. None reacted to the first dose when administered according to the end point skin prick test. On the other side, ten out of 20 children (50%) from the control group showed mild allergic reactions to the first dose of milk. In conclusion the end point skin prick test procedure results safe and easy to be performed in each single child in order to find out the starting dose for oral desensitization to milk, also by taking into account the individual variability. PMID:19624618

  19. Correlates of Narrow Bracketing

    DEFF Research Database (Denmark)

    Koch, Alexander; Nafziger, Julia

    We examine whether different phenomena of narrow bracketing can be traced back to some common characteristic and whether and how different phenomena are related. We find that making dominated lottery choices or ignoring the endowment when making risky choices are related phenomena and are both as...

  20. [Effects of different resin removal methods on shear bond strength of rebonded orthodontic brackets].

    Science.gov (United States)

    Wu, Hai-miao; Zhao, Bin-jiao; Chen, Dong

    2015-06-01

    To compare the shear bond strength (SBS) of rebonded orthodontic metal brackets with different resin removal methods. Forty extracted premolars were chosen as samples and divided into 4 experimental groups. The teeth were bonded with brackets. The brackets from 3 groups were debonded while adhesive remnants were removed from bracket bases by methods of grinding, sandblasting, and direct flaming, respectively and then rebonded. The SBS values of all rebonded brackets were determined after pH cycling experiment for 30 days. Some rebonded bracket bases were selected and observed under scanning electron microscope (SEM). The data was analyzed by one-way ANOVA test using SPSS 13.0 software package. Statistical analysis revealed a significant difference of SBS values among the 4 experimental groups (Pbrackets after resin removal by grinding and sandblasting have a similar SBS compared to the initial brackets adhesive.

  1. Ion Release and Galvanic Corrosion of Different Orthodontic Brackets and Wires in Artificial Saliva.

    Science.gov (United States)

    Tahmasbi, Soodeh; Sheikh, Tahereh; Hemmati, Yasamin B

    2017-03-01

    To investigate the galvanic corrosion of brackets manufactured by four different companies coupled with stainless steel (SS) or nickel-titanium (NiTi) wires in an artificial saliva solution. A total of 24 mandibular central incisor Roth brackets of four different manufacturers (American Orthodontics, Dentaurum, Shinye, ORJ) were used in this experimental study. These brackets were immersed in artificial saliva along with SS or NiTi orthodontic wires (0.016'', round) for 28 days. The electric potential difference of each bracket/ wire coupled with a saturated calomel reference electrode was measured via a voltmeter and recorded constantly. Corrosion rate (CR) was calculated, and release of ions was measured with an atomic absorption spectrometer. Stereomicroscope was used to evaluate all samples. Then, samples with corrosion were further assessed by scanning electron microscope and energy-dispersive X-ray spectroscopy. Two-way analysis of variance was used to analyze data. Among ions evaluated, release of nickel ions from Shinye brackets was significantly higher than that of other brackets. The mean potential difference was significantly lower in specimens containing a couple of Shinye brackets and SS wire compared with other specimens. No significant difference was observed in the mean CR of various groups (p > 0.05). Microscopic evaluation showed corrosion in two samples only: Shinye bracket coupled with SS wire and American Orthodontics bracket coupled with NiTi wire. Shinye brackets coupled with SS wire showed more susceptibility to galvanic corrosion. There were no significant differences among specimens in terms of the CR or released ions except the release of Ni ions, which was higher in Shinye brackets.

  2. Desensitization of metastable intermolecular composites

    Science.gov (United States)

    Busse, James R [South Fork, CO; Dye, Robert C [Los Alamos, NM; Foley, Timothy J [Los Alamos, NM; Higa, Kelvin T [Ridgecrest, CA; Jorgensen, Betty S [Jemez Springs, NM; Sanders, Victor E [White Rock, NM; Son, Steven F [Los Alamos, NM

    2011-04-26

    A method to substantially desensitize a metastable intermolecular composite material to electrostatic discharge and friction comprising mixing the composite material with an organic diluent and removing enough organic diluent from the mixture to form a mixture with a substantially putty-like consistency, as well as a concomitant method of recovering the metastable intermolecular composite material.

  3. Parental desensitization to violence and sex in movies.

    Science.gov (United States)

    Romer, Daniel; Jamieson, Patrick E; Bushman, Brad J; Bleakley, Amy; Wang, Anli; Langleben, Daniel; Jamieson, Kathleen Hall

    2014-11-01

    To assess desensitization in parents' repeated exposure to violence and sex in movies. A national US sample of 1000 parents living with at least 1 target child in 1 of 3 age groups (6 to 17 years old) viewed a random sequence of 3 pairs of short scenes with either violent or sexual content from popular movies that were unrestricted to youth audiences (rated PG-13 or unrated) or restricted to those under age 17 years without adult supervision (rated R). Parents indicated the minimum age they would consider appropriate to view each film. Predictors included order of presentation, parent and child characteristics, and parent movie viewing history. As exposure to successive clips progressed, parents supported younger ages of appropriate exposure, starting at age 16.9 years (95% confidence interval [CI], 16.8 to 17.0) for violence and age 17.2 years (95% CI, 17.0 to 17.4) for sex, and declining to age 13.9 years (95% CI, 13.7 to 14.1) for violence and 14.0 years (95% CI, 13.7 to 14.3) for sex. Parents also reported increasing willingness to allow their target child to view the movies as exposures progressed. Desensitization was observed across parent and child characteristics, violence toward both human and non-human victims, and movie rating. Those who frequently watched movies were more readily desensitized to violence. Parents become desensitized to both violence and sex in movies, which may contribute to the increasing acceptance of both types of content by both parents and the raters employed by the film industry. Copyright © 2014 by the American Academy of Pediatrics.

  4. Adhesion of Porphyromonas gingivalis and Biofilm Formation on Different Types of Orthodontic Brackets

    Directory of Open Access Journals (Sweden)

    William Papaioannou

    2012-01-01

    Full Text Available Objectives. To examine the interaction between Porphyromonas gingivalis and 3 different orthodontic brackets in vitro, focusing on the effect of an early salivary pellicle and other bacteria on the formation of biofilms. Material and Methods. Mono- and multi-species P. gingivalis biofilms were allowed to form in vitro, on 3 different bracket types (stainless steel, ceramic and plastic with and without an early salivary pellicle. The brackets were anaerobically incubated for 3 days in Brain Heart Infusion Broth to form biofilms. Bacteria were quantified by trypsin treatment and enumeration of the total viable counts of bacteria recovered. Results. Saliva was found to significantly affect (<0.001 adhesion and biofilm formation of P. gingivalis, with higher numbers for the coated brackets. No significant effect was detected for the impact of the type of biofilm, although on stainless steel and plastic brackets there was a tendency for higher numbers of the pathogen in multi-species biofilms. Bracket material alone was not found to affect the number of bacteria. Conclusions. The salivary pellicle seems to facilitate the adhesion of P. gingivalis and biofilm formation on orthodontic brackets, while the material comprising the brackets does not significantly impact on the number of bacteria.

  5. Comparison of the efficacy of tooth alignment among lingual and labial brackets: an in vitro study.

    Science.gov (United States)

    Alobeid, Ahmad; El-Bialy, Tarek; Reimann, Susanne; Keilig, Ludger; Cornelius, Dirk; Jäger, Andreas; Bourauel, Christoph

    2018-03-13

    The aim of this study was to evaluate the efficacy of tooth alignment with conventional and self-ligating labial and lingual orthodontic bracket systems. We tested labial brackets (0.022″ slot size) and lingual brackets (0.018″ slot size). The labial brackets were: (i) regular twin brackets (GAC-Twin [Dentsply]), (ii) passive self-ligating brackets including (Damon-Q® [ORMCO]; Ortho classic H4™ [Orthoclassic]; FLI®SL [RMO]), and (iii) active self-ligating brackets (GAC In-Ovation®C [DENTSPLY] and SPEED™[Strite]). The lingual brackets included (i) twin bracket systems (Incognito [3M] and Joy™ [Adenta]), (ii) passive self-ligating bracket system (GAC In-Ovation®LM™ [Dentsply]), and (iii) active self-ligating bracket system (Evolution SLT [Adenta]). The tested wires were Thermalloy-NiTi 0.013″ and 0.014″ (RMO). The archwires were tied to the regular twin brackets with stainless steel ligatures 0.010″ (RMO). The malocclusion simulated a displaced maxillary central incisor in the x-axis (2 mm gingivally) and in the z-axis (2 mm labially). The results showed that lingual brackets are less efficient in aligning teeth when compared with labial brackets in general. The vertical correction achieved by labial bracket systems ranged from 72 to 95 per cent with 13″ Thermalloy wires and from 70 to 87 per cent with 14″ Thermalloy wires. In contrast, the achieved corrections by lingual brackets with 13″ Thermalloy wires ranged between 25-44 per cent and 29-52 per cent for the 14" Thermalloy wires. The anteroposterior correction achieved by labial brackets ranged between 83 and 138 per cent for the 13″ Thermalloy and between 82 and 129 per cent for the 14″ Thermalloy wires. On the other hand, lingual brackets corrections ranged between 12 and 40 per cent for the 13″ Thermalloy wires and between 30 and 45 per cent for the 14″ Thermalloy wires. This is a lab-based study with different labial and lingual bracket slot sizes (however they are the

  6. Clinical practice - Drug desensitization in children

    NARCIS (Netherlands)

    de Groot, H.; Mulder, W.M.C.

    2010-01-01

    Immediate type allergic reactions to medication are potentially life threatening and can hamper drug therapy of several medical conditions. Exact incidence and prevalence data for these reactions in children are lacking. If no alternative drug treatment is available, a desensitization procedure may

  7. Perioperative Desensitization Improves Outcomes Among Crossmatch Positive Recipients of Deceased Donor Renal Transplants.

    Science.gov (United States)

    Sharma, Amit; King, Anne; Kumar, Dhiren; Behnke, Martha; McDougan, Felecia; Kimball, Pamela M

    2016-06-01

    Graft failure due to chronic rejection is greater among renal transplant patients with donor-specific antibody (DSA) than among DSA-free patients. For patients dependent on deceased donor transplantation, preoperative desensitization to eliminate DSAs may be impractical. We speculated that perioperative desensitization might eliminate preexisting DSAs and prevent de novo DSAs and improve graft outcomes. We report that brief perioperative desensitization using either intravenous immunoglobulin (IVIG) or plasmapheresis/IVIG (PP/IVIG) treatment improves clinical outcomes among patients with positive crossmatches. Immediately following deceased donor transplantation, 235 renal recipients were assigned points for PRA and flow crossmatches (FCXM): delayed graft function (DGF) ≤ 1 point received standard therapy; 2 points received high-dose IVIG; and ≥3 points received PP/IVIG. The DSAs were serially monitored by single antigen bead luminex for 1 year. Five-year clinical outcomes were determined from the chart review. All desensitized patients had preoperatively positive FCXM with DSA. Rejection was more common (P desensitized than nonsensitized groups. However, overall graft survivals were similar between the groups (P = not significant) and superior to historic untreated patients (P 90% in all desensitizated patients with DSA elimination as well as PP/IVIG patients with residual DSA. In contrast, IVIG patients with persistent DSA had poorer graft survival (45%, P desensitization improved overall graft survival of sensitized patients compared to historic untreated patients. Plasmapheresis/IVIG had greater impact on DSA eradication and graft survival than IVIG alone. © 2016, NATCO.

  8. Comparative evaluation of nickel discharge from brackets in artificial saliva at different time intervals.

    Science.gov (United States)

    Jithesh, C; Venkataramana, V; Penumatsa, Narendravarma; Reddy, S N; Poornima, K Y; Rajasigamani, K

    2015-08-01

    To determine and compare the potential difference of nickel release from three different orthodontic brackets, in different artificial pH, in different time intervals. Twenty-seven samples of three different orthodontic brackets were selected and grouped as 1, 2, and 3. Each group was divided into three subgroups depending on the type of orthodontic brackets, salivary pH and the time interval. The Nickel release from each subgroup were analyzed by using inductively coupled plasma-Atomic Emission Spectrophotometer (Perkin Elmer, Optima 2100 DV, USA) model. Quantitative analysis of nickel was performed three times, and the mean value was used as result. ANOVA (F-test) was used to test the significant difference among the groups at 0.05 level of significance (P brackets have the highest at all 4.2 pH except in 120 h. The study result shows that the nickel release from the recycled stainless steel brackets is highest. Metal slot ceramic bracket release significantly less nickel. So, recycled stainless steel brackets should not be used for nickel allergic patients. Metal slot ceramic brackets are advisable.

  9. A multi-center randomized controlled trial to compare a self-ligating bracket with a conventional bracket in a UK population: Part 1: Treatment efficiency.

    Science.gov (United States)

    O'Dywer, Lian; Littlewood, Simon J; Rahman, Shahla; Spencer, R James; Barber, Sophy K; Russell, Joanne S

    2016-01-01

    To use a two-arm parallel trial to compare treatment efficiency between a self-ligating and a conventional preadjusted edgewise appliance system. A prospective multi-center randomized controlled clinical trial was conducted in three hospital orthodontic departments. Subjects were randomly allocated to receive treatment with either a self-ligating (3M SmartClip) or conventional (3M Victory) preadjusted edgewise appliance bracket system using a computer-generated random sequence concealed in opaque envelopes, with stratification for operator and center. Two operators followed a standardized protocol regarding bracket bonding procedure and archwire sequence. Efficiency of each ligation system was assessed by comparing the duration of treatment (months), total number of appointments (scheduled and emergency visits), and number of bracket bond failures. One hundred thirty-eight subjects (mean age 14 years 11 months) were enrolled in the study, of which 135 subjects (97.8%) completed treatment. The mean treatment time and number of visits were 25.12 months and 19.97 visits in the SmartClip group and 25.80 months and 20.37 visits in the Victory group. The overall bond failure rate was 6.6% for the SmartClip and 7.2% for Victory, with a similar debond distribution between the two appliances. No significant differences were found between the bracket systems in any of the outcome measures. No serious harm was observed from either bracket system. There was no clinically significant difference in treatment efficiency between treatment with a self-ligating bracket system and a conventional ligation system.

  10. An in vitro Evaluation of Friction Characteristics of Conventional Stainless Steel and Self-ligating Stainless Steel Brackets with different Dimensions of Archwires in Various Bracket-archwire Combination.

    Science.gov (United States)

    Sridharan, K; Sandbhor, Shailesh; Rajasekaran, U B; Sam, George; Ramees, M Mohamed; Abraham, Esther A

    2017-08-01

    The purpose of this research is to compare the frictional attributes of stainless steel conventional brackets and self-ligating stainless steel brackets with different dimensions of archwires. The test was carried with two sets of maxillary brackets: (1) Conventional stainless steel (Victory Series), (2) stainless steel self-ligating (SmartClip) without first premolar brackets. Stainless steel, nickel-titanium (NiTi), and beta-Ti which are the types of orthodontic wire alloys were tested in this study. To monitor the frictional force, a universal testing machine (Instron 33R 4467) that comprises 10 kg tension load cell was assigned on a range of 1 kg and determined from 0 to 2 kg, which allows moving of an archwire along the brackets. One-way analysis of variance was used to test the difference between groups. To analyze the statistical difference between the two groups, Student's t-test was used. For Victory Series in static friction, p-value was 0.946 and for kinetic friction it was 0.944; at the same time for SmartClip, the p value for static and kinetic frictional resistance was 0.497 and 0.518 respectively. Hence, there was no statistically significant difference between the NiTi and stainless steel archwires. It is concluded that when compared with conventional brackets with stainless steel ligatures, self-ligating brackets can produce significantly less friction during sliding. Beta-Ti archwires expressed high amount of frictional resistance and the stainless steel archwires comprise low frictional resistance among all the archwire materials. In orthodontics, frictional resistance has always had a major role. Its ability to impair tooth movement leads to the need for higher forces to move the teeth and it extends the treatment time which results in loss of posterior anchorage. Friction in orthodontics is related with sliding mechanics when a wire is moving through one or a series of bracket slots.

  11. the use of systematic desensitization in psychotherapy

    African Journals Online (AJOL)

    relaxation inhibits anxiety-their concurrent expression is physiologically impossible. ..... fifth-floor balcony without discomfort. Four months after her return ... specific rather than 'free-floating' anxiety is present, systematic ,. 6. desensitization is ...

  12. Finite Element Analysis Design of a Split Rotor Bracket for a Bulb Turbine Generator

    Directory of Open Access Journals (Sweden)

    Yongyao Luo

    2013-01-01

    Full Text Available The rotor bracket is a key component of the generator rotor with cracks in the rotor bracket leading to rubbing between the rotor and stator, which threatens safe operation of the unit. The rotor rim is so complicated that the equivalent radial stiffness of rim was determined by numerical simulation other than engineering experience. A comprehensive numerical method including finite element analyses and the contact method for multibody dynamics has been used to design the split rotor bracket. The com-putational results showed that cracks would occur in the initial design of the bracket when the turbine operated at the runaway speed, and the bracket design should be improved. The improved design of the bracket was strong enough to avoid cracks and rub between the rotor and stator. This design experience will help improve the design of split rotor brackets for bulb turbine generators.

  13. Lymphocyte-mediated regulation of platelet activation during desensitization in patients with hymenoptera venom hypersensitivity.

    Science.gov (United States)

    Ledru, E; Pestel, J; Tsicopoulos, A; Joseph, M; Wallaert, B; Tonnel, A B; Capron, A

    1988-01-01

    T cells from peripheral blood of hymenoptera sensitive patients were studied before and after venom desensitization. Before treatment, T cells showed a variable but higher proliferative response to allergen than T cells of treated patients or controls. While before desensitization, T cell products, specifically released after in vitro allergen stimulation, were able to amplify the IgE-dependent platelet activity, we showed that after treatment of the same patients, T cell products strongly reduced platelet activation. Considering the modifications in platelet activation previously observed in patients treated by specific immunotherapy, the present results suggest that, through a modification of T cell reactivity to allergen, T cell functions are modulated by desensitization, and emphasize the involvement of T cell products in the desensitization mechanisms. PMID:3263227

  14. Endemic Images and the Desensitization Process.

    Science.gov (United States)

    Saigh, Philip A.; Antoun, Fouad T.

    1984-01-01

    Examined the effects of endemic images on levels of anxiety and achievement of 48 high school students. Results suggested that a combination of endemic images and study skills training was as effective as desensitization plus study skills training. Includes the endemic image questionnaire. (JAC)

  15. Evaluation of the friction force generated by monocristalyne and policristalyne ceramic brackets in sliding mechanics.

    Science.gov (United States)

    Pimentel, Roberta Ferreira; de Oliveira, Roberto Sotto Maior Fortes; Chaves, Maria das Graças Afonso Miranda; Elias, Carlos Nelson; Gravina, Marco Abdo

    2013-01-01

    To evaluate and compare "in vitro" the maximum friction force generated by three types of esthetic brackets, two types of polycrystalline conventional ceramic brackets (20/40 and InVu) and one type of sapphire monocrystalline bracket (Radiance) in dry and artificial saliva wet settings. Also, to evaluate the influence exerted by artificial saliva on the friction forces of those brackets. Tests were performed in dry and artificial saliva wet setting (Oral Balance) by using an EMIC DL 10000 testing machine, simulating a 2 mm slide of 0.019 x 0.025-in rectangular stainless steel wires over the pre-angulated and pre-torqued (right superior canine, Roth prescription, slot 0.022 x 0.030-in) brackets (n = 18 for each bracket). In order to compare groups in dry and wet settings, the ANOVA was used. For comparisons related to the dry versus wet setting, the student t test was used for each group. The results showed that in the absence of saliva the Radiance monocrystalline brackets showed the highest friction coefficients, followed by the 20/40 and the InVu polycrystalline brackets. In tests with artificial saliva, the Radiance and the 20/40 brackets had statistically similar friction coefficients and both were greater than that presented by the InVu brackets. The artificial saliva did not change the maximum friction force of the Radiance brackets, but, for the others (20/40 and InVu), an increase of friction was observed in its presence. The InVu brackets showed, in the absence and in the presence of saliva, the lowest friction coefficient.

  16. Rapid drug desensitization for hypersensitivity reactions to chemotherapy and monoclonal antibodies in the 21st century.

    Science.gov (United States)

    Castells Guitart, M C

    2014-01-01

    The frequency of hypersensitivity reactions (HSR) to drugs has risen in the last 10 years owing to increased exposure to better and more allergenic medications including monoclonal antibodies. HSRs prevent patients from using their first-line therapy, leading to decreased quality of life and life expectancy. Although premedication with antihistamines, leukotriene blockers, and corticosteroids can protect against mild-to-moderate HSR, none of these medications has provided protection against anaphylaxis. Rapid drug desensitization is a treatment option for patients with HSR to their first-line medication that protects against anaphylaxis.Although the mechanisms of drug desensitization are not completely understood, in vitro mast cell models of IgE antigen desensitization have led to the design of safe and effective in vivo protocols aimed at protecting highly sensitized patients from hypersensitivity reactions and anaphylaxis. This review provides an insight into the mechanisms of IgE/mast cell desensitization, the principles and practice of drug desensitization, and an overview of the different desensitization protocols and their safety and efficacy profiles. Drug desensitization should only be performed by allergists, trained nurses, and experienced pharmacists, since this high-risk procedure involves reintroducing allergenic medication to highly sensitized patients, with the consequent potential for severe or fatal HSRs.

  17. Optimization of Compressor Mounting Bracket of a Passenger Car

    Science.gov (United States)

    Kalsi, Sachin; Singh, Daljeet; Saini, J. S.

    2018-05-01

    In the present work, the CAE tools are used for the optimization of the compressor mounting bracket used in an automobile. Both static and dynamic analysis is done for the bracket. With the objective to minimize the mass and increase the stiffness of the bracket, the new design is optimized using shape and topology optimization techniques. The optimized design given by CAE tool is then validated experimentally. The new design results in lower level of vibrations, contribute to lower mass along with lesser cost which is effective in air conditioning system as well as the efficiency of a vehicle. The results given by CAE tool had a very good correlation with the experimental results.

  18. Acute activation, desensitization and smoldering activation of human acetylcholine receptors.

    Directory of Open Access Journals (Sweden)

    Barbara G Campling

    Full Text Available The behavioral effects of nicotine and other nicotinic agonists are mediated by AChRs in the brain. The relative contribution of acute activation versus chronic desensitization of AChRs is unknown. Sustained "smoldering activation" occurs over a range of agonist concentrations at which activated and desensitized AChRs are present in equilibrium. We used a fluorescent dye sensitive to changes in membrane potential to examine the effects of acute activation and chronic desensitization by nicotinic AChR agonists on cell lines expressing human α4β2, α3β4 and α7 AChRs. We examined the effects of acute and prolonged application of nicotine and the partial agonists varenicline, cytisine and sazetidine-A on these AChRs. The range of concentrations over which nicotine causes smoldering activation of α4β2 AChRs was centered at 0.13 µM, a level found in smokers. However, nicotine produced smoldering activation of α3β4 and α7 AChRs at concentrations well above levels found in smokers. The α4β2 expressing cell line contains a mixture of two stoichiometries, namely (α4β22β2 and (α4β22α4. The (α4β22β2 stoichiometry is more sensitive to activation by nicotine. Sazetidine-A activates and desensitizes only this stoichiometry. Varenicline, cytisine and sazetidine-A were partial agonists on this mixture of α4β2 AChRs, but full agonists on α3β4 and α7 AChRs. It has been reported that cytisine and varenicline are most efficacious on the (α4β22α4 stoichiometry. In this study, we distinguish the dual effects of activation and desensitization of AChRs by these nicotinic agonists and define the range of concentrations over which smoldering activation can be sustained.

  19. Gyrokinetic energy conservation and Poisson-bracket formulation

    International Nuclear Information System (INIS)

    Brizard, A.

    1989-01-01

    An integral expression for the gyrokinetic total energy of a magnetized plasma, with general magnetic field configuration perturbed by fully electromagnetic fields, was recently derived through the use of a gyrocenter Lie transformation. It is shown that the gyrokinetic energy is conserved by the gyrokinetic Hamiltonian flow to all orders in perturbed fields. An explicit demonstration that a gyrokinetic Hamiltonian containing quadratic nonlinearities preserves the gyrokinetic energy up to third order is given. The Poisson-bracket formulation greatly facilitates this demonstration with the help of the Jacobi identity and other properties of the Poisson brackets

  20. Cow's Milk Desensitization in Anaphylactic Patients: A New Personalized-dose Method.

    Science.gov (United States)

    Babaie, Delara; Nabavi, Mohammad; Arshi, Saba; Mesdaghi, Mehrnaz; Chavoshzadeh, Zahra; Bemanian, Mohammad Hasan; Tafakori, Mitra; Amirmoini, Mehrdad; Esmailzadeh, Hosein; Molatefi, Rasoul; Rekabi, Mahsa; Akbarpour, Nadieh; Masoumi, Farimah; Fallahpour, Morteza

    2017-02-01

    Cow's milk allergy (CMA) is the most frequent food allergy in children and oral immunotherapy (OIT) is a promising approach for treatment of patients. The most challenging cases are anaphylactic with coexisting asthma and proposing safe protocols is crucial especially in high risk groups. Considering that CMA varies among patients, an individualized OIT protocol would be beneficial to achieve a safer and more efficient method of desensitization. 18 children more than 3 years of age with IgE-mediated CMA were enrolled. CMA was confirmed by positive skin prick test (SPT) and positive oral food challenge (OFC) and 60% of individuals had a convincing history of persistent asthma. SPT with milk extracts, whole fresh milk and serially diluted milk concentrations were performed.  The dilution of milk that induced 3-5 mm of wheal in each individual was selected as the starting dilution for OIT. Desensitization began by 1 drop of the defined dilution and continued increasingly. Overall, 16 out of 18 children (88.8%) achieved the daily intake of 120 mL of milk. Four out of these 16 children accomplished the protocol without any adverse allergic reactions. 12 patients experienced mild to severe reactions. Wheal and erythema in SPT (p≤0.001), and sIgE (p≤0.003) to most milk allergens were significantly decreased following desensitization. We successfully desensitized 16 of 18 children with IgE-mediated CMA by individualized desensitization protocol. Individualizing the OIT protocol would be helpful to save time and perhaps to relieve the allergic symptoms after ingesting cow's milk intake.

  1. Effects of Two Short-Term Desensitization Methods in the Treatment of Test Anxiety

    Science.gov (United States)

    Richardson, Frank C.; Suinn, Richard M.

    1974-01-01

    Accelerated massed desensitization and anxiety management training were compared with standard systematic desensitization in terms of reducing self-reported test anxiety in high test-anxious college students. All three treatments significantly reduced test anxiety as compared with a waiting list control group. (Author)

  2. Group Systematic Desensitization Versus Covert Positive Reinforcement in the Reduction of Test Anxiety

    Science.gov (United States)

    Kostka, Marion P.; Galassi, John P.

    1974-01-01

    The study compared modified versions of systematic desensitization and covert positive reinforcement to a no-treatment control condition in the reduction of test anxiety. On an anagrams performance test, the covert reinforcement and control groups were superior to the desensitization group. (Author)

  3. Hypersensitivity and desensitization to antineoplastic agents: outcomes of 189 procedures with a new short protocol and novel diagnostic tools assessment.

    Science.gov (United States)

    Madrigal-Burgaleta, R; Berges-Gimeno, M P; Angel-Pereira, D; Ferreiro-Monteagudo, R; Guillen-Ponce, C; Pueyo, C; Gomez de Salazar, E; Alvarez-Cuesta, E

    2013-07-01

    Desensitization to antineoplastic agents is becoming a standard of care. Efforts to establish and improve these techniques are being made at many institutions. Our aims are to evaluate a new rapid desensitization protocol designed to be shorter (approximately 4 h) and safer (reducing hazardous drugs exposure risks) and to assess the oxaliplatin-specific immunoglobulin E (IgE) as a novel diagnostic tool. Prospective, observational, longitudinal study with patients who, for a 1-year period, suffered reactions to antineoplastic agents and were referred to the Desensitization Program at Ramon y Cajal University Hospital (RCUH). Patients were included or excluded as desensitization candidates after anamnesis, skin testing, risk assessment, and graded challenge. Specific IgE was determined in oxaliplatin-reactive patients. Candidate patients were desensitized using the new RCUH rapid desensitization protocol. Of 189 intravenous rapid desensitizations, 188 were successfully accomplished in the 23 patients who met inclusion criteria for desensitization (of 58 referred patients). No breakthrough reactions occurred in 94% of desensitizations, and most breakthrough reactions were mild. In 10 oxaliplatin-reactive patients, 38 desensitizations were successfully accomplished. Sensitivity for oxaliplatin-specific IgE was 38% (0.35UI/l cutoff point) and 54% (0.10UI/l cutoff point); specificity was 100% for both cutoff points. In the hands of a Desensitization Program, managed by drug desensitization experts, this new protocol has proven an effective therapeutic tool for hypersensitivity to several antineoplastic agents (oxaliplatin, carboplatin, paclitaxel, docetaxel, cyclophosphamide, and rituximab); moreover, it improves safety handling of hazardous drugs. We report the first large series of oxaliplatin desensitizations. Oxaliplatin-specific IgE determination could be helpful. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. The desensitization gating of the MthK K+ channel is governed by its cytoplasmic amino terminus.

    Directory of Open Access Journals (Sweden)

    Mario Meng-Chiang Kuo

    2008-10-01

    Full Text Available The RCK-containing MthK channel undergoes two inactivation processes: activation-coupled desensitization and acid-induced inactivation. The acid inactivation is mediated by the C-terminal RCK domain assembly. Here, we report that the desensitization gating is governed by a desensitization domain (DD of the cytoplasmic N-terminal 17 residues. Deletion of DD completely removes the desensitization, and the process can be fully restored by a synthetic DD peptide added in trans. Mutagenesis analyses reveal a sequence-specific determinant for desensitization within the initial hydrophobic segment of DD. Proton nuclear magnetic resonance ((1H NMR spectroscopy analyses with synthetic peptides and isolated RCK show interactions between the two terminal domains. Additionally, we show that deletion of DD does not affect the acid-induced inactivation, indicating that the two inactivation processes are mutually independent. Our results demonstrate that the short N-terminal DD of MthK functions as a complete moveable module responsible for the desensitization. Its interaction with the C-terminal RCK domain may play a role in the gating process.

  5. Intraoral corrosion of self-ligating metallic brackets and archwires and the effect on friction

    Science.gov (United States)

    Tima, Lori Lynn

    The purpose of this study was to investigate how the frictional coefficient was affected due to intraoral use. A secondary aim of this study was to determine whether or not there was a relationship between corrosion of orthodontic alloys and friction via scanning electron microscopic qualitative analysis. Orthodontic brackets and 0.019 x 0.025 inch stainless steel archwires were collected and divided into three groups of n=10: used bracket and used wires (UBUW), used brackets and new wires (UBNW), and new brackets and new wires (NBNW). New materials were as-received from the manufacturer, and used materials were clinically used bracket and wires collected from patients following orthodontic treatment. Archwires were pulled through bracket slots at a rate of 0.5mm/min while friction forces were measured. Following a cleaning process, the surface topography of the bracket slots was examined under a scanning electron microscope (SEM). Based on a 1-factor MANOVA, there was no significant group effect (all p>0.05) on frictional forces. Partial eta squared values indicated that intraoral exposure had only a small effect on frictional forces (≤ 3%). Qualitative analysis of SEM images did not show an association between surface characteristics of the bracket slots and magnitude of frictional force. Results suggest that surface corrosion from intraoral use does not significantly affect friction at the bracket wire interface.

  6. Receptor downregulation and desensitization enhance the information processing ability of signalling receptors

    Directory of Open Access Journals (Sweden)

    Resat Haluk

    2007-11-01

    Full Text Available Abstract Background In addition to initiating signaling events, the activation of cell surface receptors also triggers regulatory processes that restrict the duration of signaling. Acute attenuation of signaling can be accomplished either via ligand-induced internalization of receptors (endocytic downregulation or via ligand-induced receptor desensitization. These phenomena have traditionally been viewed in the context of adaptation wherein the receptor system enters a refractory state in the presence of sustained ligand stimuli and thereby prevents the cell from over-responding to the ligand. Here we use the epidermal growth factor receptor (EGFR and G-protein coupled receptors (GPCR as model systems to respectively examine the effects of downregulation and desensitization on the ability of signaling receptors to decode time-varying ligand stimuli. Results Using a mathematical model, we show that downregulation and desensitization mechanisms can lead to tight and efficient input-output coupling thereby ensuring synchronous processing of ligand inputs. Frequency response analysis indicates that upstream elements of the EGFR and GPCR networks behave like low-pass filters with the system being able to faithfully transduce inputs below a critical frequency. Receptor downregulation and desensitization increase the filter bandwidth thereby enabling the receptor systems to decode inputs in a wider frequency range. Further, system-theoretic analysis reveals that the receptor systems are analogous to classical mechanical over-damped systems. This analogy enables us to metaphorically describe downregulation and desensitization as phenomena that make the systems more resilient in responding to ligand perturbations thereby improving the stability of the system resting state. Conclusion Our findings suggest that in addition to serving as mechanisms for adaptation, receptor downregulation and desensitization can play a critical role in temporal information

  7. Formulation of Hamiltonian mechanics with even and odd Poisson brackets

    International Nuclear Information System (INIS)

    Khudaverdyan, O.M.; Nersesyan, A.P.

    1987-01-01

    A possibility is studied as to constrict the odd Poisson bracket and odd Hamiltonian by the given dynamics in phase superspace - the even Poisson bracket and even Hamiltonian so the transition to the new structure does not change the equations of motion. 9 refs

  8. Immune Profiles to Predict Response to Desensitization Therapy in Highly HLA-Sensitized Kidney Transplant Candidates.

    Science.gov (United States)

    Yabu, Julie M; Siebert, Janet C; Maecker, Holden T

    2016-01-01

    Kidney transplantation is the most effective treatment for end-stage kidney disease. Sensitization, the formation of human leukocyte antigen (HLA) antibodies, remains a major barrier to successful kidney transplantation. Despite the implementation of desensitization strategies, many candidates fail to respond. Current progress is hindered by the lack of biomarkers to predict response and to guide therapy. Our objective was to determine whether differences in immune and gene profiles may help identify which candidates will respond to desensitization therapy. Single-cell mass cytometry by time-of-flight (CyTOF) phenotyping, gene arrays, and phosphoepitope flow cytometry were performed in a study of 20 highly sensitized kidney transplant candidates undergoing desensitization therapy. Responders to desensitization therapy were defined as 5% or greater decrease in cumulative calculated panel reactive antibody (cPRA) levels, and non-responders had 0% decrease in cPRA. Using a decision tree analysis, we found that a combination of transitional B cell and regulatory T cell (Treg) frequencies at baseline before initiation of desensitization therapy could distinguish responders from non-responders. Using a support vector machine (SVM) and longitudinal data, TRAF3IP3 transcripts and HLA-DR-CD38+CD4+ T cells could also distinguish responders from non-responders. Combining all assays in a multivariate analysis and elastic net regression model with 72 analytes, we identified seven that were highly interrelated and eleven that predicted response to desensitization therapy. Measuring baseline and longitudinal immune and gene profiles could provide a useful strategy to distinguish responders from non-responders to desensitization therapy. This study presents the integration of novel translational studies including CyTOF immunophenotyping in a multivariate analysis model that has potential applications to predict response to desensitization, select candidates, and personalize

  9. Evaluation of friction in orthodontics using various brackets and archwire combinations-an in vitro study.

    Science.gov (United States)

    Kumar, Sujeet; Singh, Shamsher; Hamsa P R, Rani; Ahmed, Sameer; Prasanthma; Bhatnagar, Apoorva; Sidhu, Manreet; Shetty, Pramod

    2014-05-01

    The aim of this study was to compare frictional resistance which was produced between conventional brackets (0.022 slot Otho-Organiser) and self ligating brackets (active Forestadent and passive Damon III) by using various arch wire combinations (0.016 Niti, 0.018 Niti, 0.017 x 0.025 SS and 0.019 x 0.025 SS). An experimental model which consisted of 5 aligned stainless steel 0.022-in brackets was used to assess frictional forces which were produced by SLBs (self ligating brackets) and CELs (conventional elastomeric ligatures) with use of 0.016 nickel titanium, 0.018 nickel titanium, 0.017 X 0.025"stainless steel and 0.019 X 0.025"stainless steel wires. One way ANOVA test was used to study the effect of the bracket type, wire alloy and section on frictional resistance test . Conventional brackets produced highest levels of friction for all bracket/archwire combinations. Both Damon III and Forestadent brackets were found to produce significantly lower levels of friction when they were compared with elastomerically tied conventional brackets. SLBs are valid alternatives for low friction during sliding mechanics.

  10. Anaphylactic reaction to polyethylene-glycol conjugated-asparaginase: premedication and desensitization may not be sufficient.

    Science.gov (United States)

    Sahiner, Umit M; Yavuz, S Tolga; Gökce, Muge; Buyuktiryaki, Betul; Altan, Ilhan; Aytac, Selin; Tuncer, Murat; Tuncer, Ayfer; Sackesen, Cansin

    2013-08-01

    In hypersensitive reactions to native L-asparaginase, either premedication and desensitization or substitution with polyethylene glycol conjugated asparaginase (PEG-ASP) is preferred. Anaphylaxis with PEG-ASP is rare. An 8-year-old girl and a 2.5-year-old boy, both diagnosed as having acute lymphoblastic leukemia, presented with native L-asparaginase hypersensitivity and substitution with PEG-ASP was preferred. They received a premedication (methylprednisolone, hydroxyzine and ranitidine) followed by desensitization with PEG-ASP infusion. Both patients developed anaphylaxis with peg-asparaginase. These are the first reported cases of anaphylactic reaction to PEG-ASP, despite the application of both premedication and desensitization. Anaphylaxis with PEG-ASP is very rare and premedication and desensitization protocols may not prevent these hypersensitive reactions. © 2013 The Authors. Pediatrics International © 2013 Japan Pediatric Society.

  11. Comparison of Anxiety Management Training and Desensitization in Reducing Test and Other Anxieties.

    Science.gov (United States)

    Deffenbacher, Jerry L.; Shelton, John L.

    1978-01-01

    Effects of systematic desensitization and anxiety management training in reducing test anxiety and generalizing to other anxieties were compared. Both desensitization and anxiety management training produced significant reduction of text anxiety, but by follow-up, anxiety management training produced significantly more test-anxiety reduction on…

  12. Nanosilver coated orthodontic brackets: in vivo antibacterial properties and ion release.

    Science.gov (United States)

    Metin-Gürsoy, Gamze; Taner, Lale; Akca, Gülçin

    2017-02-01

    Silver nanoparticles are currently utilized in the fields of dentistry. The aim of this study was to evaluate the antibacterial properties and ion release of nanosilver coated orthodontic brackets compared to conventional brackets. Nanosilver coating process was applied to standard orthodontic brackets placed on the mandibular incisors of Wistar Albino rats in the study group and conventional brackets in the control group. Dental plaque, mucosal vestibular smears, saliva, and blood samples were collected from rats at various days. The amounts of nanosilver ions in blood and saliva were measured and microbiological evaluation was made for Streptococcus mutans. For testing cariogenicity, all rats were sacrificed at the end of 75 days under anaesthesia. Teeth were stained using a caries indicator, then the caries ratio was assessed. Nanosilver coated orthodontic bracket favoured the inhibition of S.mutans on Day 30 and reduction of caries on the smooth surfaces. The nanosilver amounts in the saliva and serum samples were significantly higher in the study group on Day 7. It is suggested that nanosilver coated orthodontic brackets, as an antibacterial agent without patient compliance, could be helpful for the prevention of white spot lesions during fixed orthodontic treatment. © The Author 2016. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  13. Comparative assessment of different recycling methods of orthodontic brackets for clinical use.

    Science.gov (United States)

    de Oliveira Correia, Ayla M; de Souza Matos, Felipe; Pilli Jóias, Renata; de Mello Rode, Sigmar; Cesar, Paulo F; Paranhos, Luiz R

    2017-06-01

    This study aimed to assess bond strength of the resin/bracket interface, under in-vitro shear stress, of metal brackets recycled by different clinical protocols. Sixty stainless steel orthodontic brackets were bonded on acrylic resin. The Transbond XT™ resin was applied at the base of the bracket aided by a matrix, obtaining 1 mm of thickness, and photoactivated with a LED device (40 s; 500 mW/cm2). Samples were randomly divided into four groups (N.=15) according to the reconditioning/recycling protocol: aluminum oxide (AO) 90 µm; hydrofluoric acid 60 s (HA60); hydrofluoric acid 120 s (HA120); hydrofluoric acid 60 s + silane (HA60S). After recycling, the resin was applied at the base of the bracket for shear testing in a universal testing machine (0.5 mm/min). After reconditioning/recycling, the surfaces were analyzed by Scanning Electron Microscopy. Data obtained after the shear test were subjected to ANOVA and Tukey's test (Porthodontic brackets when compared to the other protocols. The reconditioning technique with 10% hydrofluoric acid followed by the application of silane bonding agent may be used as an alternative protocol.

  14. Comparison of deflection forces of esthetic archwires combined with ceramic brackets*

    Science.gov (United States)

    MATIAS, Murilo; de FREITAS, Marcos Roberto; de FREITAS, Karina Maria Salvatore; JANSON, Guilherme; HIGA, Rodrigo Hitoshi; FRANCISCONI, Manoela Fávaro

    2018-01-01

    Abstract Coated archwires and ceramic brackets have been developed to improve facial esthetics during orthodontic treatment. However, their mechanical behavior has been shown to be different from metallic archwires and brackets. Therefore, the aim of this study was to compare the deflection forces in coated nickel-titanium (NiTi) and esthetic archwires combined with ceramic brackets. Material and Methods Non-coated NiTi (NC), rhodium coated NiTi (RC), teflon coated NiTi (TC), epoxy coated NiTi (EC), fiber-reinforced polymer (FRP), and the three different conventional brackets metal-insert polycrystalline ceramic (MI-PC), polycrystalline ceramic (PC) and monocrystalline ceramic (MC) were used. The specimens were set up on a clinical simulation device and evaluated in a Universal Testing Machine (Instron). An acrylic device, representative of the right maxillary central incisor was buccolingually activated and the unloading forces generated were recorded at 3, 2, 1 and 0.5 mm. The speed of the testing machine was 2 mm/min. ANOVA and Tukey tests were used to compare the different archwires and brackets. Results The brackets presented the following decreasing force ranking: monocrystalline, polycrystalline and polycrystalline metal-insert. The decreasing force ranking of the archwires was: rhodium coated NiTi (RC), non-coated NiTi (NC), teflon coated NiTi (TC), epoxy coated NiTi (EC) and fiber-reinforced polymer (FRP). At 3 mm of unloading the FRP archwire had a plastic deformation and produced an extremely low force in 2; 1 and 0.5 mm of unloading. Conclusion Combinations of the evaluated archwires and brackets will produce a force ranking proportional to the combination of their individual force rankings. PMID:29451650

  15. Comparison of deflection forces of esthetic archwires combined with ceramic brackets.

    Science.gov (United States)

    Matias, Murilo; Freitas, Marcos Roberto de; Freitas, Karina Maria Salvatore de; Janson, Guilherme; Higa, Rodrigo Hitoshi; Francisconi, Manoela Fávaro

    2018-01-01

    Coated archwires and ceramic brackets have been developed to improve facial esthetics during orthodontic treatment. However, their mechanical behavior has been shown to be different from metallic archwires and brackets. Therefore, the aim of this study was to compare the deflection forces in coated nickel-titanium (NiTi) and esthetic archwires combined with ceramic brackets. Material and Methods Non-coated NiTi (NC), rhodium coated NiTi (RC), teflon coated NiTi (TC), epoxy coated NiTi (EC), fiber-reinforced polymer (FRP), and the three different conventional brackets metal-insert polycrystalline ceramic (MI-PC), polycrystalline ceramic (PC) and monocrystalline ceramic (MC) were used. The specimens were set up on a clinical simulation device and evaluated in a Universal Testing Machine (Instron). An acrylic device, representative of the right maxillary central incisor was buccolingually activated and the unloading forces generated were recorded at 3, 2, 1 and 0.5 mm. The speed of the testing machine was 2 mm/min. ANOVA and Tukey tests were used to compare the different archwires and brackets. Results The brackets presented the following decreasing force ranking: monocrystalline, polycrystalline and polycrystalline metal-insert. The decreasing force ranking of the archwires was: rhodium coated NiTi (RC), non-coated NiTi (NC), teflon coated NiTi (TC), epoxy coated NiTi (EC) and fiber-reinforced polymer (FRP). At 3 mm of unloading the FRP archwire had a plastic deformation and produced an extremely low force in 2; 1 and 0.5 mm of unloading. Conclusion Combinations of the evaluated archwires and brackets will produce a force ranking proportional to the combination of their individual force rankings.

  16. Occurrence and severity of enamel decalcification adjacent to bracket bases and sub-bracket lesions during orthodontic treatment with two different lingual appliances

    Science.gov (United States)

    Klang, Elisabeth; Helms, Hans-Joachim; Wiechmann, Dirk

    2016-01-01

    Summary Background: Using lingual enamel surfaces for bracket placement not only has esthetic advantages, but may also be suitable in terms of reducing frequencies of enamel decalcifications. Objective: To test the null-hypothesis that there is no significant difference in enamel decalcification or cavitation incidence adjacent to and beneath bracket bases between two lingual multi-bracket (MB) appliances that are different in terms of design, material composition, and manufacturing technology (group A: WIN, DW-LingualSystems; group B: Incognito, 3M-Unitek), taking into account patient- and treatment-related variables on white spot lesion (WSL) formation. Methods: Standardized, digital, top-view photographs of 630 consecutive subjects (16214 teeth; n Incognito = 237/6076 teeth; n WIN = 393/10138 teeth; mean age: 17.47±7.8; m/f 43.2/56.8%) with completed lingual MB treatment of the upper and lower permanent teeth 1–7 were screened for decalcification or cavitation adjacent to and beneath the bracket bases before and after treatment, scored from 0 to 7. Non-parametric ANOVA was used for main effects ‘appliance type’, ‘gender’, ‘treatment complexity’, ‘grouped age’ (≤16/>16 years), and ‘treatment duration’ as covariable, at an α-level of 5%. Results: About 2.57% [5.94%] of all teeth in group A [B] developed decalcifications. Subject-related incidence was 9.59% [16.17%] for upper incisors in group A [B], and 12.98% [25.74%] for all teeth 16–46. There were significant effects by gender, age, and treatment duration. Conclusion: The null-hypothesis was rejected: sub-bracket lesions were significantly less frequent in group A, while frequencies of WSL adjacent to brackets were not significantly affected by appliance type. In view of the overall low incidences of lingual post-orthodontic white-spot lesions, the use of lingual appliances is advocated as a valid strategy for a reduction of enamel decalcifications during orthodontic treatment. PMID

  17. The Kauffman bracket and the Jones polynomial in quantum gravity

    International Nuclear Information System (INIS)

    Griego, J.

    1996-01-01

    In the loop representation the quantum states of gravity are given by knot invariants. From general arguments concerning the loop transform of the exponential of the Chern-Simons form, a certain expansion of the Kauffman bracket knot polynomial can be formally viewed as a solution of the Hamiltonian constraint with a cosmological constant in the loop representation. The Kauffman bracket is closely related to the Jones polynomial. In this paper the operation of the Hamiltonian on the power expansions of the Kauffman bracket and Jones polynomials is analyzed. It is explicitly shown that the Kauffman bracket is a formal solution of the Hamiltonian constraint to third order in the cosmological constant. We make use of the extended loop representation of quantum gravity where the analytic calculation can be thoroughly accomplished. Some peculiarities of the extended loop calculus are considered and the significance of the results to the case of the conventional loop representation is discussed. (orig.)

  18. The influence of different bracket base surfaces on tensile and shear bond strength

    NARCIS (Netherlands)

    Algera, T.J.; Kleverlaan, C.J.; Prahl-Andersen, B.; Feilzer, A.J.

    2008-01-01

    Fracture of the bracket-cement-enamel system usually takes place between the bracket and the cement. Especially for glass ionomer-based materials, it is helpful if this part of the system can be improved. The aim of this in vitro study was to investigate the influence of different bracket base

  19. Comparison of static friction with self-ligating, modified slot design and conventional brackets

    Directory of Open Access Journals (Sweden)

    Raquel Morais Castro

    2013-07-01

    Full Text Available OBJECTIVE: To compare the static frictional forces generated at the bracket/wire interface of stainless steel brackets with different geometries and angulations, combined with orthodontic wires of different diameters. MATERIAL AND METHODS: The frictional forces were evaluated with three different types of metal brackets: a passive self-ligating (SmartClipTM, 3M/Unitek, Monrovia, USA, with a modified slot design (Mini Uni TwinTM, 3M/Unitek, Monrovia, USA and conventional (Kirium, Abzil, São José do Rio Preto, Brazil. The samples were mounted in a testing device with three different angulations and tested with 0.014" and 0.018" stainless steel wires (American Orthodontics, Sheboygan, USA. The static frictional force was measured using a universal testing machine (DL 500, EMIC®, São José dos Pinhais, Brazil with a crosshead speed of 1 mm/min. Statistical analysis was performed by two-way ANOVA followed by Bonferroni's post hoc test. RESULTS: There was a significant difference (p<0.05 in static friction when the three types of brackets were tested with the same wire size. The wire diameter influenced friction only when the brackets had a 10º angulation (p<0.05. The angulation influenced friction (p<0.05 when the brackets were associated with a 0.018" wire. CONCLUSION: Brackets with a modified slot design showed intermediate static frictional force values between the conventional and self-ligating brackets tested.

  20. Er,Cr:YSGG Laser as a Novel Method for Rebonding Failed Ceramic Brackets.

    Science.gov (United States)

    Sohrabi, Aydin; Jafari, Sanaz; Kimyai, Soodabeh; Rikhtehgaran, Sahand

    2016-10-01

    Since there is no standard method for rebonding loose ceramic brackets, the aim of this study was to evaluate the possibility of using Er,Cr:YSGG laser to eliminate the remaining composite materials from the base of ceramic brackets and to compare the bond strength of rebonded brackets with the new ones. Sixty-two extracted human premolars were mounted in acrylic cylinders. Thirty-one ceramic brackets were bonded, and shear bond strength was tested using Hounsfield testing machine. The remnants of the bonding material were removed from the bases of brackets using Er,Cr:YSGG laser. These brackets were rebonded to 31 fresh teeth and again shear bond strength was measured. Pattern of debonding was assessed in both cases under a stereomicroscope and graded according to ARI index. Data were analyzed with independent t-test and Fisher's exact test. Mean shear bond strength of the bond and rebond groups was 12.29 ± 5.46 and 10.58 ± 5.16 MPa, respectively. There were no significant differences between the two groups (p = 0.21). Pattern of bond failure was not statistically different between the two groups. Er,Cr:YSGG laser was effective in removing the remnants of bonding material from the base of ceramic brackets without any interference with the ceramic base itself, demonstrating that it might be a suitable method for rebonding ceramic brackets.

  1. Gingival response in orthodontic patients: Comparative study between self-ligating and conventional brackets.

    Science.gov (United States)

    Folco, Alejandra A; Benítez-Rogé, Sandra C; Iglesias, Marina; Calabrese, Diana; Pelizardi, Cristina; Rosa, Alcira; Brusca, Marisa I; Hecht, Pedro; Mateu, María E

    2014-01-01

    Orthodontic brackets contribute to the accumulation of bacterial plaque on tooth surfaces because they hinder oral hygiene. In contrast to conventional brackets, self-ligating brackets do not require additional parts to support the arches, thus improving dental hygiene. The aim of this study was to compare the gingival response in orthodontic patients wearing self-ligating or conventional brackets. A sample of 22 patients aged 16 to 30 years was divided into two groups: Group A, treated with selfligating brackets (Damon system) and Group B, treated with conventional brackets (Roth technique). The following were assessed during the treatment: Plaque Index (PI), Gingival Index (GI) and Probing Depth (PD), and sub-gingival samples were taken from teeth 14/24 for microbiological observation. No statistically significant difference was found between Groups A and B; p>0.05 (sign-ranked) or between PI, GI and PD at the different times (Friedman's Analysis of Variance), even though the indices were found to increase at 14 days, particularly for self-ligating brackets. The quantity and quality of microorganisms present were compatible with health on days 0, 28 and 56. As from day 14 there is a predominance of microbiota compatible with gingivitis in both groups. In the samples studied, orthodontic treatment increases bacterial plaque and inflammatory gingival response, but gingival-periodontal health can be maintained with adequate basic therapy. Self-ligating and conventional brackets produced similar gingival response.

  2. Flooding and Systematic Desensitization: Efficacy in Subclinical Phobics as a Function of Arousal

    Science.gov (United States)

    Suarez, Yolanda; And Others

    1976-01-01

    Flooding and systematic desensitization procedures were investigated for possible interactions with subject arousal level on reduction in phobic reactions. No such interaction was found. Behaviorally and on GSR response, both flooding and systematic desensitization were effective, but only the latter was effective on subjective reports. (NG)

  3. In vitro study of color stability of polycrystalline and monocrystalline ceramic brackets.

    Science.gov (United States)

    de Oliveira, Cibele Braga; Maia, Luiz Guilherme Martins; Santos-Pinto, Ary; Gandini Junior, Luiz Gonzaga

    2014-01-01

    The aim of this in vitro study was to analyze color stability of monocrystalline and polycrystalline ceramic brackets after immersion in dye solutions. Seven ceramic brackets of four commercial brands were tested: Two monocrystalline and two polycrystalline. The brackets were immersed in four dye solutions (coffee, red wine, Coke and black tea) and in artificial saliva for the following times: 24 hours, 7, 14 and 21 days, respectively. Color changes were measured by a spectrophotometer. Data were assessed by Multivariate Profile Analysis, Analysis of Variance (ANOVA) and Multiple Comparison Tests of means. There was a perceptible change of color in all ceramic brackets immersed in coffee (ΔE* Allure = 7.61, Inspire Ice = 6.09, Radiance = 6.69, Transcend = 7.44), black tea (ΔE* Allure = 6.24, Inspire Ice = 5.21, Radiance = 6.51, Transcend = 6.14) and red wine (ΔE* Allure = 6.49, Inspire Ice = 4.76, Radiance = 5.19, Transcend = 5.64), but no change was noticed in Coke and artificial saliva (ΔE brackets undergo color change when exposed to solutions of coffee, black tea and red wine. However, the same crystalline structure, either monocrystalline or polycrystalline, do not follow the same or a similar pattern in color change, varying according to the bracket fabrication, which shows a lack of standardization in the manufacturing process. Coffee dye produced the most marked color changes after 21 days of immersion for most ceramic brackets evaluated.

  4. Galvanic coupling of steel and gold alloy lingual brackets with orthodontic wires.

    Science.gov (United States)

    Polychronis, Georgios; Al Jabbari, Youssef S; Eliades, Theodore; Zinelis, Spiros

    2018-03-06

    The aim of this research was to assess galvanic behavior of lingual orthodontic brackets coupled with representative types of orthodontic wires. Three types of lingual brackets: Incognito (INC), In-Ovation L (IOV), and STb (STB) were combined with a stainless steel (SS) and a nickel-titanium (NiTi) orthodontic archwire. All materials were initially investigated by scanning electron microscopy / x-ray energy dispersive spectroscopy (SEM/EDX) while wires were also tested by x-ray diffraction spectroscopy (XRD). All bracket-wire combinations were immersed in acidic 0.1M NaCl 0.1M lactic acid and neutral NaF 0.3% (wt) electrolyte, and the potential differences were continuously recorded for 48 hours. The SEM/EDX analysis revealed that INC is a single-unit bracket made of a high gold (Au) alloy while IOV and STB are two-piece appliances in which the base and wing are made of SS alloys. The SS wire demonstrated austenite and martensite iron phase, while NiTi wire illustrated an intense austenite crystallographic structure with limited martensite. All bracket wire combinations showed potential differences below the threshold of galvanic corrosion (200 mV) except for INC and STB coupled with NiTi wire in NaF media. The electrochemical results indicate that all brackets tested demonstrated galvanic compatibility with SS wire, but fluoride treatment should be used cautiously with NiTi wires coupled with Au and SS brackets.

  5. Ion release from orthodontic brackets in 3 mouthwashes: an in-vitro study.

    Science.gov (United States)

    Danaei, Shahla Momeni; Safavi, Afsaneh; Roeinpeikar, S M Mehdi; Oshagh, Morteza; Iranpour, Shiva; Omidkhoda, Maryam; Omidekhoda, Maryam

    2011-06-01

    Stainless steel orthodontic brackets can release metal ions into the saliva. Fluoridated mouthwashes are often recommended to orthodontic patients to reduce the risk of white-spot lesions around their brackets. However, little information is available regarding the effect of different mouthwashes in ion release of orthodontic brackets. The purpose of this study was to measure the amount of metal ion release from orthodontic brackets when kept in different mouthwashes. One hundred sixty stainless steel brackets (0.022-in, 3M Unitek, Monrovia, Calif) were divided randomly into 4 equal groups and immersed in Oral B (Procter & Gamble, Weybridge, United Kingdom), chlorhexidine (Shahdaru Labratories, Tehran, Iran), and Persica (Poursina Pharmaceutical Laboratories, Tehran, Iran) mouthwashes and distilled deionized water and incubated at 37°C for 45 days. Nickel, chromium, iron, copper, and manganese released from the orthodontic brackets were measured with an inductively coupled plasma spectrometer. For statistical analysis, 1-way analysis of variance (ANOVA) and the Duncan multiple-range tests were used. The results showed that ion release in deionized water was significantly (P 0.05) in nickel, chromium, iron, and copper ion release in the Oral B and Persica mouthwashes. The level of manganese release was significantly different in all 4 groups. If ion release is a concern, Oral B and Persica mouthwashes might be better options than chlorhexidine for orthodontic patients with stainless steel brackets. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  6. Bond efficacy of recycled orthodontic brackets: A comparative in vitro evaluation of two methods.

    Science.gov (United States)

    Shetty, Vikram; Shekatkar, Yash; Kumbhat, Neesu; Gautam, G; Karbelkar, Shalan; Vandekar, Meghna

    2015-01-01

    Recycling of orthodontic brackets in developing orthodontic economies is an extremely common procedure. Bonding protocols and reliability of these brackets is, however, questionable, and still the subject of research. The aim was to evaluate and compare the shear bond strength of brackets recycled with sandblasting and silicoating. Ninety extracted human premolars were bonded with 0.022" SS brackets (American Orthodontics, Sheboygan USA) and then debonded. The debonded brackets were divided into three groups of 30 each. Group I: Sandblasting with 50-μm aluminum oxide (control group) Group II: Sandblasting with 50-μm aluminum oxide followed by metal primer application Group III: Silicoating with 30-μm Cojet sand followed by silane application and rebonded with Transbond XT. The sandblasted brackets and silicoated brackets were viewed under the scanning electron microscope, immediately after surface conditioning before rebonding. The shear bond strength with each group was tested. One-way analysis of variance, post-hoc Scheffe multiple comparison tests. The results showed that sandblasting created more irregularities and deeper erosions while silica coating created superficial irregularities and shallow erosions.

  7. Assessment of Ions released from Three Types of Orthodontic Brackets immersed in Different Mouthwashes: An in vitro Study.

    Science.gov (United States)

    Nahidh, Mohammed; Garma, Noor Mh; Jasim, Esraa S

    2018-01-01

    Herbs are used widely in medicine. The purpose of the present study was to assess the ion release from gold-plated orthodontic bracket compared with other stainless steel brackets, and based on the findings of the study, the orthodontists can choose the most biocompatible brackets and mouthwashes useful in the clinical practice. A total of 150 orthodontic brackets from Orthotechnology™ Company, USA (50 stainless steel one-piece brackets, 50 stainless steel two-piece brackets, and 50 gold brackets) were immersed in four mouthwashes in addition to distilled water. Ten of each type of brackets in every media were immersed under 37°C for 45 days. Ions released in these mouthwashes were measured, and comparisons among different bracket types and among various mouthwashes were done by one-way analysis of variance (ANOVA) and then with Games-Howell tests. Increased amounts of ions released in herbal mouth-washes were recorded in gold and two-piece brackets in comparison with one-piece stainless steel brackets. Herbal mouthwashes must be used with caution as they showed an increased amount of ions released in comparison with chlorhexidine. One-piece stainless steel bracket system is the most compatible bracket type, as they released the least amount of ions. One-piece stainless steel brackets are better than two-piece brackets in terms of ions released.

  8. Seismic response Analyses of Hanaro in-chimney bracket structures

    International Nuclear Information System (INIS)

    Lee, Jae Han; Ryu, J.S.; Cho, Y.G.; Lee, H.Y.; Kim, J.B.

    1999-05-01

    The in-chimney bracket will be installed in the upper part of chimney, which holds the capsule extension pipes in upper one-third of length. For evaluating the effects on the capsules and related reactor structures, ANSYS finite element analysis model is developed and the dynamic characteristics are analyzed. The seismic response anlayses of in-chimney bracket and related reactor structures of HANARO under the design earthquake response spectrum loads of OBE (0.1 g) and SSE (0.2 g) are performed. The maximum horizontal displacements of the flow tubes are within the minimum half gaps between close flow tubes, it is expected that these displacement will not produce any contact between neighbor flow tubes. The stress values in main points of reactor structures and in-chimney bracket for the seismic loads are also within the ASME Code limits. It is also confirmed that the fatigue usage factor is much less than 1.0. So, any damage on structural integrity is not expected when an in-chimney bracket is installed to upper part of the reactor chimney. (author). 12 refs., 24 tabs., 37 figs

  9. Actual versus theoretical torsional play in conventional and self-ligating bracket systems

    DEFF Research Database (Denmark)

    Dalstra, Michel; Eriksen, Henrik; Bergamini, Chiara

    2015-01-01

    Abstract Objective: The aim of this study was to assess the amount of torsional play in 32 commercially available self-ligating and conventional 0·018-inch and 0·022-inch bracket systems in relation to 0·017×0·022-inch and 0·019×0·025-inch stainless steel wires, respectively, and compare...... the results with the theoretical amount of play for the given bracket/wire combinations. Methods: Torque moments were measured in a mechanical force testing system by twisting straight pieces of stainless steel wire seated in the bracket slot in increments of 0·5° until a full torsional expression...... and the inability of self-ligation brackets to press the archwire into the bottom of the slot. In conventional brackets, the initial torque moment is generated by the steel ligatures pressing the arch wire against the bottom of the slot. The oversize of the slot is thus less critical in relation to the conventional...

  10. Intrapulpal Temperature Increase During Er:YAG Laser-Aided Debonding of Ceramic Brackets.

    Science.gov (United States)

    Yilanci, Hilal; Yildirim, Zeynep Beyza; Ramoglu, Sabri Ilhan

    2017-04-01

    The purpose of this study was to evaluate the temperature changes in the pulp chamber while using a newly introduced application of Er:YAG laser to debond ceramic brackets in a study model with a pulpal circulation with and without thermocycled samples. An esthetic alternative to stainless steel brackets, ceramic brackets have been proposed. However, because of their low fracture resistance and high bond strengths, ceramic brackets can cause a problem when they are being removed using conventional techniques. Experimental Groups A and B were established for samples with or without thermocycling. The same 20 maxillary central incisor and 20 premolar teeth were used in both groups. Pulpal blood microcirculation was simulated using an apparatus described in a previous study. Monocrystalline brackets were bonded by using Transbond XT. In Group A, brackets were debonded using the Er:YAG laser (600 mJ, 2 Hz, long pulse, and no air or water spray) after being stored in distilled water for 24 h. In Group B, brackets were debonded using the same laser system as that used in Group A after being stored in distilled water for 24 h and then thermocycled for a total of 5000 cycles between 5°C and 55°C. The laser irradiation duration and intrapulpal temperature changes were measured. In Group B, the intrapulpal temperature increase of the central incisors was significantly higher than that of the premolar teeth. In the central incisor and premolar teeth groups, there were no statistically significant difference between Groups A and B (p > 0.05). A positive correlation was found between laser irradiation duration and temperature increase (p brackets. This method can be used safely under the consideration of intrapulpal temperature changes.

  11. Investigation of bracket bonding for orthodontic treatments using en-face optical coherence tomography

    Science.gov (United States)

    Sinescu, Cosmin; Negrutiu, Meda L.; Hughes, Michael; Bradu, Adrian; Todea, Carmen; Rominu, Roxana; Dodenciu, Dorin; Laissue, Philippe L.; Podoleanu, Adrian G.

    2008-04-01

    Despite good diagnosis and treatment planning, orthodontic treatment can fail if bonding fails. It is now common practice to address the aesthetic appearance of patients using aesthetic brackets instead of metal ones. Therefore, bonding aesthetic brackets has become an issue for orthodontists today. Orthodontic bonding is mainly achieved using composite resin but can also be performed with glass ionomer or resin cements. For improving the quality of bonding, the enamel is acid etched for 30 seconds with 38% phosphoric acid and then a bonding agent is applied. In our study we investigated and compared the quality of bonding between ceramic brackets, polymeric brackets and enamel, respectively using a new investigation method-OCT. The aim of our study was to evaluate the resin layer at the bracket base-tooth interface.

  12. A Comparative Evaluation of Adherence of Microorganism to Different Types of Brackets: A Scanning Electron Microscopic Study.

    Science.gov (United States)

    Shashidhar, E P; Sahitya, M; Sunil, T; Murthy, Anup R; Rani, M S

    2015-09-01

    The purpose of this study was to evaluate and compare the adherence of microorganism to different types of brackets using the scanning electron microscope (SEM). A double-blinded study was undertaken to evaluate and adherence of microorganisms to different types of brackets using SEM. At random, 12 patients reporting for treatment to the department of Orthodontics VS Dental College and Hospital were selected. Four types of brackets were included in the present study stainless steel, titanium, composite, and ceramic. Brackets were bonded to teeth of the patient on all the four quadrants. The teeth included for bonding were lateral incisor, canine, first premolar, and second premolar. The brackets were left for 72 h. After 72 h brackets were debonded, and they were evaluated by SEM for adherence of microorganism in the slot and tie wings surface. The SEM images were graded, and the adherence of microorganism to the brackets in the surfaces and the four different quadrants were recorded. There is a significant difference in adherence of microorganisms to the various types of brackets (P 0.05) included in the study. The interaction of bracket/surface, bracket/quadrant, surface/quadrants was analyzed, there was no significance of comparison of bracket/surfaces/quadrant but the interaction of bracket/quadrant was found to be significant (bracket/surfaces/quadrant was also found to be significant (bracket material and the least adherence of microorganisms was observed with the titanium bracket material. The adherence of microorganisms is relatively more in the slot area, when compare to the tie wings surface maximum adherence of microorganism is observed in the upper left quadrant and least adherence of microorganism is observed in the lower right quadrant. There is a significant difference in adherence of microorganisms to various types of brackets and the surfaces included in the study. There is no significant difference in the adherence of microorganism to the bracket

  13. Torque efficiency of square and rectangular archwires into 0.018 and 0.022 in. conventional brackets.

    Science.gov (United States)

    Papageorgiou, Spyridon N; Sifakakis, Iosif; Doulis, Ioannis; Eliades, Theodore; Bourauel, Christoph

    2016-01-01

    The aim of this study was to compare the torque efficacy of square and rectangular wires in 0.018- and 0.022-in. conventionally ligated brackets. Brackets of the same prescription were evaluated in both slot dimensions. Identical acrylic resin models of the maxilla were bonded with the brackets and mounted on the Orthodontic Measurement and Simulation System. Ten 0.018 × 0.018 in., 0.018 × 0.022 in., and 0.018 × 0.025 in. stainless steel wires were evaluated in the 0.018-in. brackets and ten 0.019 × 0.019 in., 0.019 × 0.025 in., and 0.019 × 0.026 in. stainless steel wires were evaluated in the 0.022-in. brackets. A 15° buccal root torque was gradually applied to the right central incisor bracket, and the moments were recorded at this position. One-way ANOVA was applied for both bracket slot sizes along with post hoc analysis for the various archwire sizes. The mean measured moments varied between 10.78 and 30.60 Nmm among the assessed wire-and-bracket combinations. Both square and rectangular archwires in the 0.018-in. bracket system exerted statistically significantly higher moments in comparison with their counterparts in the 0.022-in. bracket system. Rectangular archwires exerted statistically significantly higher moments than square archwires, both for the 0.018- and the 0.022-in. bracket system. Rectangular archwires seem to be more efficient in torque exertion, especially in 0.018-in. brackets.

  14. Structural Integrity Evaluation of an New In-Chimney Bracket Structures for HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Jeong Soo; Cho, Yeong Garp; Lee, Jung Hee; Jung, Hoan Sung; Seo, Choon Gyo; Shin, Jin Won

    2007-12-15

    In HANARO are there provided three hexagonal irradiation holes (CT, IR1 and IR2) in the central region of the core while four circular irradiation holes (OR3 {approx} OR6) in the outer core. There exist two types of irradiation facilities: uninstrumented or instrumented. The uninstrumented irradiation facility is little influenced by the coolant flow. But the dynamic behavior by the flow-induced vibration (FIV) and seismic loads is expected to largely occur in case of the instrumented test facility due to the long guide tube to protect the instrumentation cables. To suppress this dynamic behavior of the facility, the in-chimney bracket was designed. As a supplementary supporting structure for irradiation facility, this bracket will hold guide tubes whose holding position of the instrumented facility in CT or IR is the middle part of the instrumented facility between the hole spider and the robot arm already provided in the reactor pool liner. On the while, the bracket will grip the upper part of the guide tube when it is applied to hold the instrumented facility loaded in OR sites. Therefore it is believed that the irradiation test can be successfully conducted since this bracket can reduce the FIV and dynamic response to seismic load as well. In new in-chimney bracket, IR1 is reserved for IPS(In-Pile Section) so only CT/IR2 guide tubes are supported by CT/IR clamp units and the shape of In-chimney bracket is redesigned. For evaluating the structural integrity on the new in-chimney bracket and related reactor structures, ANSYS finite element analysis model is developed and the dynamic characteristics are analyzed. The seismic response analyses of new in-chimney bracket and related reactor structures of HANARO under the design earthquake response spectrum loads of OBE(0.1g) and SSE(0.2g) are performed. The response shows that the stress values for main points on the reactor structures and the new in-chimney bracket for seismic loads are within the ASME Code limits

  15. Comparison of the frictional characteristics of aesthetic orthodontic brackets measured using a modified in vitro technique

    Science.gov (United States)

    Arici, Nursel

    2015-01-01

    Objective The coefficients of friction (COFs) of aesthetic ceramic and stainless steel brackets used in conjunction with stainless steel archwires were investigated using a modified linear tribometer and special computer software, and the effects of the bracket slot size (0.018 inches [in] or 0.022 in) and materials (ceramic or metal) on the COF were determined. Methods Four types of ceramic (one with a stainless steel slot) and one conventional stainless steel bracket were tested with two types of archwire sizes: a 0.017 × 0.025-in wire in the 0.018-in slots and a 0.019 × 0.025-in wire in the 0.022-in slot brackets. For pairwise comparisons between the 0.018-in and 0.022-in slot sizes in the same bracket, an independent sample t-test was used. One-way and two-way analysis of variance (ANOVA) and Tukey's post-hoc test at the 95% confidence level (α = 0.05) were also used for statistical analyses. Results There were significant differences between the 0.022-in and 0.018-in slot sizes for the same brand of bracket. ANOVA also showed that both slot size and bracket slot material had significant effects on COF values (p bracket with a 0.022-in stainless steel slot showed the lowest mean COF (µ = 0.18), followed by the conventional stainless steel bracket with a 0.022-in slot (µ = 0.21). The monocrystalline alumina ceramic bracket with a 0.018-in slot had the highest COF (µ = 0.85). Conclusions Brackets with stainless steel slots exhibit lower COFs than ceramic slot brackets. All brackets show lower COFs as the slot size increases. PMID:25667915

  16. Hyperventilation in a motion sickness desensitization program

    NARCIS (Netherlands)

    Mert, A.; Bles, W.; Nooij, S.A.E.

    2007-01-01

    Introduction: In motion sickness desensitization programs, the motion sickness provocative stimulus is often a forward bending of the trunk on a rotating chair, inducing Coriolis effects. Since respiratory relaxation techniques are applied successfully in these courses, we investigated whether these

  17. Role Of Expectancy Manipulation In Systematic Desensitization

    Science.gov (United States)

    Brown, H. Alan

    1973-01-01

    Expectancy, relaxation, and hierarchy content were manipulated. Findings did not support the hypothesis that expectancy was the only factor in desensitization, but did clarify the role of expectancy vis-a-vis the counterconditioning elements typically discussed in the literature. (Author)

  18. Comparison of the force levels among labial and lingual self-ligating and conventional brackets in simulated misaligned teeth.

    Science.gov (United States)

    Alobeid, Ahmad; El-Bialy, Tarek; Khawatmi, Said; Dirk, Cornelius; Jäger, Andreas; Bourauel, Christoph

    2017-08-01

    The aim of this study was to evaluate force levels exerted by levelling arch wires with labial and lingual conventional and self-ligating brackets. The tested orthodontic brackets were of the 0.022-in slot size for labial and 0.018-in for lingual brackets and were as follows: 1. Labial brackets: (i) conventional bracket (GAC-Twin, Dentsply), (ii) passive self-ligating (SL) brackets (Damon-Q®, ORMCO; Ortho classic H4™, Orthoclassic; FLI®SL, Rocky Mountain Orthodontics) and (iii) active SL brackets (GAC In-Ovation®C, DENTSPLY and SPEED™, Strite). 2. Lingual brackets: (i) conventional brackets (Incognito, 3M and Joy™, Adenta); (ii) passive SL bracket (GAC In-Ovation®LM™, Dentsply and (iii) active SL bracket (Evolution SLT, Adenta). Thermalloy-NiTi 0.013-in and 0.014-in arch wires (Rocky Mountain Orthodontics) were used with all brackets. The simulated malocclusion represented a maxillary central incisor displaced 2 mm gingivally (x-axis) and 2 mm labially (z-axis). Lingual bracket systems showed higher force levels (2.4 ± 0.2 to 3.8 ± 0.2 N) compared to labial bracket systems (from 1.1 ± 0.1 to 2.2 ± 0.4 N). However, the differences between SL and conventional bracket systems were minor and not consistent (labial brackets: 1.2 ± 0.1 N for the GAC Twin and 1.1 ± 0.1 to 1.6 ± 0.1 N for the SL brackets with 0.013-in thermalloy; lingual brackets: 2.5 ± 0.2 to 3.5 ± 0.1 N for the conventional and 2.7 ± 0.3 to 3.4 ± 0.1 N for the SL brackets with 0.013-in Thermalloy). This is an in vitro study with different slot sizes in the labial and lingual bracket systems, results should be interpreted with caution. Lingual bracket systems showed higher forces compared to labial bracket systems that might be of clinical concern. We recommend highly flexible nickel titanium arch wires lower than 0.013-in for the initial levelling and alignment especially with lingual appliances. © The Author 2017. Published by Oxford University Press on behalf of the European

  19. Friction Forces during Sliding of Various Brackets for Malaligned Teeth: An In Vitro Study

    Science.gov (United States)

    Crincoli, Vito; Di Bisceglie, Maria Beatrice; Balsamo, Antonio; Serpico, Vitaliano; Chiatante, Francesco; Pappalettere, Carmine; Boccaccio, Antonio

    2013-01-01

    Aims. To measure the friction force generated during sliding mechanics with conventional, self-ligating (Damon 3 mx, Smart Clip, and Time 3) and low-friction (Synergy) brackets using different archwire diameters and ligating systems in the presence of apical and buccal malalignments of the canine. Methods. An experimental setup reproducing the right buccal segment of the maxillary arch was designed to measure the friction force generated at the bracket/wire and wire/ligature interfaces of different brackets. A complete factorial plan was drawn up and a three-way analysis of variance (ANOVA) was carried out to investigate whether the following factors affect the values of friction force: (i) degree of malalignment, (ii) diameter of the orthodontic wire, and (iii) bracket/ligature combination. Tukey post hoc test was also conducted to evaluate any statistically significant differences between the bracket/ligature combinations analyzed. Results. ANOVA showed that all the above factors affect the friction force values. The friction force released during sliding mechanics with conventional brackets is about 5-6times higher than that released with the other investigated brackets. A quasilinear increase of the frictional forces was observed for increasing amounts of apical and buccal malalignments. Conclusion. The Synergy bracket with silicone ligature placed around the inner tie-wings appears to yield the best performance. PMID:23533364

  20. An in vitro study into the efficacy of complex tooth alignment with conventional and self-ligating brackets.

    Science.gov (United States)

    Montasser, M A; Keilig, L; Bourauel, C

    2015-02-01

    To evaluate the efficacy of tooth alignment achieved by various small cross-section archwire/bracket combinations using the orthodontic measurement and simulation system. The study comprised three types of orthodontic brackets 1) conventional ligating (Victory Series and Mini-Taurus), 2) self-ligating (SmartClip a passive self-ligating bracket and Time3 an active self-ligating bracket), and 3) a conventional low-friction bracket (Synergy). All brackets had a nominal 0.022″ slot size. Brackets were combined with 1) 0.012″ stainless steel, 2) 0.012″ Orthonol, 3) 0.012″ Thermalloy, and 4) 0.0155″ coaxial archwires. Archwires were tied to the conventional brackets with stainless steel ligatures and elastomeric rings. The malocclusion simulated represented a central upper incisor displaced 2 mm gingivally (x-axis) and 2 mm labially (z-axis). The inciso-gingival correction achieved by the different archwire/bracket combinations ranged from 15 to 95%, while the labio-lingual correction ranged from 10 to 95%. The smallest correction was achieved by coaxial, Orthonol, and thermally archwires when ligated with the elastomeric rings to conventional brackets. Stainless steel archwires achieved from 65 to 90% of inciso-gingival correction and from 60 to 90% of labio-lingual correction. The resultant tooth alignment was the product of interaction between the archwire type, bracket type, and bracket design including ligature type. Small cross-sectional archwires might produce up to 95% correction if combined properly with the bracket system. Elastomeric rings when used with conventional brackets limit the efficacy of malalignment correction. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Slot deformation of various stainless steel bracket due to the torque force of the beta-titanium wire

    Science.gov (United States)

    Huda, M. M.; Siregar, E.; Ismah, N.

    2017-08-01

    Stainless steel bracket slot deformation ffects the force applied to teeth and it can impede tooth movement and prolong orthodontic treatment time. The aim of this study is to determine the slot deformation due to torque of a 0.021 × 0.025 inch Beta Titanium wire with a torsional angle of 30° and 45° for five different bracket brands: y, 3M, Biom, Versadent, Ormco, and Shinye. The research also aims to compare the deformation and amount of torque among all five bracket brands at torsional angles of 30° and 45°. Fifty stainless steel edgewise brackets from the five bracket group brands (n=10) were attached to acrylic plates. The bracket slot measurements were carried out in two stages. In the first stage, the, deformation was measured by calculating the average bracket slot height using a stereoscopy microscope before and after application of torque. In the second stage, the torque was measured using a torque measurement apparatus. The statistical analysis shows that slot deformations were found on all five bracket brands with a clinical permanent deformation on the Biom (2.79 μm) and Shinye (2.29 μm) brackets. The most torque was observed on the 3M bracket, followed by the Ormco, Versadent, Shinye, and Biom brackets. When the brands were compared, a correlation between bracket slot deformation and the amount of torque was found, but the correlation was not statistically significant for the 3M and Ormco brackets and the Biom and Shinye brackets. There is a difference in the amount of torque between the five brands with a torsional angle of 30° (except the 3M and Ormco brackets) and those with a torsional angle of 45°. The composition of the metal and the manufacturing process are the factors that influence the occurrence of bracket slot deformation and the amount of torque. A manufacturing process using metal injection molding (MIM) and metal compositions of AISI 303 and 17-4 PH stainless steel reduce the risk of deformation.

  2. Agonist-induced desensitization of human β3-adrenoceptors expressed in human embryonic kidney cells

    NARCIS (Netherlands)

    Michel-Reher, Martina B.; Michel, Martin C.

    2013-01-01

    β3-Adrenoceptors are resistant to agonist-induced desensitization in some cell types but susceptible in others including transfected human embryonic kidney (HEK) cells. Therefore, we have studied cellular and molecular changes involved in agonist-induced β3-adrenoceptor desensitization in HEK cells.

  3. Opioid receptor desensitization: mechanisms and its link to tolerance

    Directory of Open Access Journals (Sweden)

    Stéphane eAllouche

    2014-12-01

    Full Text Available Opioid receptors are part of the class A of G-protein coupled receptors and the target of the opiates, the most powerful analgesic molecules used in clinic. During a protracted use, a tolerance to analgesic effect develops resulting in a reduction of the effectiveness. So understanding mechanisms of tolerance is a great challenge and may help to find new strategies to tackle this side effect. This review will summarize receptor-related mechanisms that could underlie tolerance especially receptor desensitization. We will focus on the latest data obtained on molecular mechanisms involved in opioid receptor desensitization: phosphorylation, receptor uncoupling, internalization and post-endocytic fate of the receptor.

  4. Accuracy of four different digital intraoral scanners: effects of the presence of orthodontic brackets and wire.

    Science.gov (United States)

    Jung, Yoo-Ran; Park, Ji-Man; Chun, Youn-Sic; Lee, Kkot-Nim; Kim, Minji

    The objective of this study was to compare the accuracy of four different digital intraoral scanners and the effects of buccal brackets and orthodontic wire. For this study, three sets of models (Control model, BKT model with buccal bracket, and WBKT model with buccal bracket and orthodontic wire) were scanned using four different types of intraoral scanners: E4D dentist, iTero, Trios, and Zfx IntraScan. The mesiodistal width of the teeth, intercanine width, and intermolar width measured by four scanners were compared. Three-dimensional (3D) images of the brackets were taken using the four scanners. Data were analyzed with one-way ANOVA, independent t test, and post-hoc Tukey test at a significance level of P brackets and orthodontic wire. Comparison of 3D bracket images scanned by the four scanners showed differences in image distortion among the scanners. Bracket characteristics did not affect the 3D bracket images. The four intraoral scanners used in this study differed in accuracy. However, the results acquired by iTero and Trios were more reliable. Effects of buccal brackets and orthodontic wire on the 3D images taken by intraoral scanners were not clinically significant.

  5. Effect of aspirin desensitization on T-cell cytokines and plasma lipoxins in aspirin-exacerbated respiratory disease.

    Science.gov (United States)

    Aksu, Kurtuluş; Kurt, Emel; Alatas, Özkan; Gülbas, Zafer

    2014-01-01

    The pathogenesis of aspirin-exacerbated respiratory disease (AERD) is thought to be based on, mainly, overproduction of eicosanoid lipid mediators and on defective anti-inflammatory regulators. Aspirin desensitization treatment, the mainstay of controlling asthma and rhinitis in AERD patients, however, is the least understood aspect of the disease. The study was designed to determine the effect of aspirin desensitization on T-lymphocyte cytokine expression and on plasma lipoxin levels in AERD. Spirometry, skin-prick test and asthma control test were documented and intracellular cytokine expression in T lymphocytes and plasma lipoxin levels were measured in 23 AERD patients, 17 aspirin-tolerant asthmatic (ATA) patients, and 16 healthy controls. In the AERD group nasal symptom and smell scores were assessed. Of the 23 AERD patients 15 accepted to undergo aspirin desensitization protocol and 14 of them were desensitized successfully. In the desensitized AERD group, cytokine and lipoxin measurements were repeated after 1-month aspirin treatment. CD4(+) IL-10 levels were higher in AERD patients than in healthy controls and CD4(+) interferon (IFN) gamma levels were higher in AERD and ATA patients than in controls. Plasma lipoxin-A4 and 15-epi-lipoxin-A4 levels were similar among the three study groups. In the AERD group, subjects underwent aspirin desensitization followed by a 1-month aspirin treatment. Clinical parameters improved and CD4(+) IFN-gamma levels decreased significantly. No significant change in lipoxin levels was recorded. CD4(+) IFN-gamma and CD4(+) IL-10 levels in AERD patients after 1-month aspirin desensitization treatment were similar to the healthy controls. The study confirms aspirin desensitization is effective clinically in AERD patients and suggests that IFN gamma and IL-10 expression in CD4(+) T lymphocytes may be related to the mechanism of action.

  6. Aplikasi eye moving desensitization dan reprocessing dalam konseling post-traumatic stress disorder

    OpenAIRE

    Hengki Satrianta

    2017-01-01

    Akhir-akhir ini banyak peristiwa yang berpotensi memunculkan efek traumatik yang jika tidak ditangani akan menimbulkan gangguan stres pascatrauma. Olehnya itu, dibutuhkan upaya-upaya untu menangani masalah ini. Salah satu upaya yang dimaksud adalah penggunaan eye moving desensitization and reprocessing. Artikel ini ditulis dengan fokus pada penanganan gangguan stres pascatrauma melalui eye moving desensitization and reprocessing. Tujuan penulisan artikel ini adalah untuk mengetahui gambaran u...

  7. B cell repertoires in HLA-sensitized kidney transplant candidates undergoing desensitization therapy.

    Science.gov (United States)

    Beausang, John F; Fan, H Christina; Sit, Rene; Hutchins, Maria U; Jirage, Kshama; Curtis, Rachael; Hutchins, Edward; Quake, Stephen R; Yabu, Julie M

    2017-01-13

    Kidney transplantation is the most effective treatment for end-stage renal disease. Sensitization refers to pre-existing antibodies against human leukocyte antigen (HLA) protein and remains a major barrier to successful transplantation. Despite implementation of desensitization strategies, many candidates fail to respond. Our objective was to determine whether measuring B cell repertoires could differentiate candidates that respond to desensitization therapy. We developed an assay based on high-throughput DNA sequencing of the variable domain of the heavy chain of immunoglobulin genes to measure changes in B cell repertoires in 19 highly HLA-sensitized kidney transplant candidates undergoing desensitization and 7 controls with low to moderate HLA sensitization levels. Responders to desensitization had a decrease of 5% points or greater in cumulated calculated panel reactive antibody (cPRA) levels, and non-responders had no decrease in cPRA. Dominant B cell clones were not observed in highly sensitized candidates, suggesting that the B cells responsible for sensitization are either not present in peripheral blood or present at comparable levels to other circulating B cells. Candidates that responded to desensitization therapy had pre-treatment repertoires composed of a larger fraction of class-switched (IgG and IgA) isotypes compared to non-responding candidates. After B cell depleting therapy, the proportion of switched isotypes increased and the mutation frequencies of the remaining non-switched isotypes (IgM and IgD) increased in both responders and non-responders, perhaps representing a shift in the repertoire towards memory B cells or plasmablasts. Conversely, after transplantation, non-switched isotypes with fewer mutations increased, suggesting a shift in the repertoire towards naïve B cells. Relative abundance of different B cell isotypes is strongly perturbed by desensitization therapy and transplantation, potentially reflecting changes in the relative

  8. In vitro study of color stability of polycrystalline and monocrystalline ceramic brackets

    OpenAIRE

    de Oliveira, Cibele Braga; Maia, Luiz Guilherme Martins; Santos-Pinto, Ary; Gandini J?nior, Luiz Gonzaga

    2014-01-01

    OBJECTIVE: The aim of this in vitro study was to analyze color stability of monocrystalline and polycrystalline ceramic brackets after immersion in dye solutions. METHODS: Seven ceramic brackets of four commercial brands were tested: Two monocrystalline and two polycrystalline. The brackets were immersed in four dye solutions (coffee, red wine, Coke and black tea) and in artificial saliva for the following times: 24 hours, 7, 14 and 21 days, respectively. Color changes were measured by a...

  9. Rapid desensitization of adrenaline- and neuropeptide Y-stimulated Ca2+ mobilization in HEL-cells

    NARCIS (Netherlands)

    Michel, M. C.

    1994-01-01

    1. Desensitization of Gs-coupled receptors, the beta 2-adrenoceptor for example, involves rapid and slower components but little is known regarding the existence of rapid desensitization of Gi-coupled receptors and its possible mechanisms. In HEL-cells stimulation of alpha 2A-adrenoceptors by

  10. Shear bond strength of metallic and ceramic brackets using color change adhesives.

    Science.gov (United States)

    Stumpf, Aisha de Souza Gomes; Bergmann, Carlos; Prietsch, José Renato; Vicenzi, Juliane

    2013-01-01

    To determine the shear bond strength of orthodontic brackets using color change adhesives that are supposed to aid in removing excess of bonding material and compare them to a traditional adhesive. Ninety metallic and ninety ceramic brackets were bonded to bovine incisors using two color change adhesives and a regular one. A tensile stress was applied by a universal testing machine. The teeth were observed in a microscope after debonding in order to determine the Adhesive Remnant Index (ARI). The statistical analysis (ANOVA, Tukey, and Kruskall-Wallis tests) demonstrated that the mean bond strength presented no difference when metallic and ceramic brackets were compared, but the bond resistance values were significantly different for the three adhesives used. The most common ARI outcome was the entire adhesive remaining on the enamel. The bond strength was similar for metallic and ceramic brackets when the same adhesive system was used. ARI scores demonstrated that bonding with these adhesives is safe even when ceramic brackets were used. On the other hand, bond strength was too low for orthodontic purposes when Ortho Lite Cure was used.

  11. Influence of lingual bracket position on microbial and periodontal parameters in vivo

    Directory of Open Access Journals (Sweden)

    Maria Francesca Sfondrini

    2012-06-01

    Full Text Available OBJECTIVE: Lingual orthodontics is becoming more popular in dental practice. The purpose of the present investigation was to compare plaque formation on teeth bonded with the same bracket onto buccal or lingual surface, with non-bonded control teeth, via an in vivo growth experiment over a 30-day period. MATERIAL AND METHODS: A randomized controlled trial with split-mouth design was set up enrolling 20 dental students. Within each subject sites with buccal and lingual brackets and control sites were followed. Clinical periodontal parameters (periodontal pocket depth: PPD; bleeding on probing: BOP were recorded at baseline and on days 1, 7 and 30. Microbiological samples were taken from the brackets and the teeth on days 1, 7 and 30 to detect colony-forming units (CFU. Total CFU, streptococci CFU and anaerobe CFU were measured. RESULTS: No significant differences (P>0.05 were found between buccal and lingual brackets in terms of clinical periodontal parameters and microbiological values. Conclusion: Bracket position does not have significant impact on bacterial load and on periodontal parameters.

  12. Desensitization and Tolerance of Mu Opioid Receptors on Pontine Kölliker-Fuse Neurons.

    Science.gov (United States)

    Levitt, Erica S; Williams, John T

    2018-01-01

    Acute desensitization of mu opioid receptors is thought to be an initial step in the development of tolerance to opioids. Given the resistance of the respiratory system to develop tolerance, desensitization of neurons in the Kölliker-Fuse (KF), a key area in the respiratory circuit, was examined. The activation of G protein-coupled inwardly rectifying potassium current was measured using whole-cell voltage-clamp recordings from KF and locus coeruleus (LC) neurons contained in acute rat brain slices. A saturating concentration of the opioid agonist [Met 5 ]-enkephalin (ME) caused significantly less desensitization in KF neurons compared with LC neurons. In contrast to LC, desensitization in KF neurons was not enhanced by activation of protein kinase C or in slices from morphine-treated rats. Cellular tolerance to ME and morphine was also lacking in KF neurons from morphine-treated rats. The lack of cellular tolerance in KF neurons correlates with the relative lack of tolerance to the respiratory depressant effect of opioids. Copyright © 2018 by The American Society for Pharmacology and Experimental Therapeutics.

  13. Resistance to Sliding in Clear and Metallic Damon 3 and Conventional Edgewise Brackets: an In vitro Study

    Science.gov (United States)

    Karim Soltani, Mohammad; Golfeshan, Farzaneh; Alizadeh, Yoones; Mehrzad, Jabraiel

    2015-01-01

    Statement of the Problem Frictional forces are considered as important counterforce to orthodontic tooth movement. It is claimed that self-ligating brackets reduce the frictional forces. Purpose The aim of this study was to compare the resistance to sliding in metallic and clear Damon brackets with the conventional brackets in a wet condition. Materials and Method The samples included 4 types of brackets; metallic and clear Damon brackets and metallic and clear conventional brackets (10 brackets in each group). In this study, stainless steel wires sized 0.019×0.025 were employed and the operator’s saliva was used to simulate the conditions of oral cavity. The tidy-modified design was used for simulation of sliding movement. The resistance to sliding and static frictional forces was measured by employing Testometric machine and load cell. Results The mean (±SD) of resistance to sliding was 194.88 (±26.65) and 226.62 (±39.9) g in the esthetic and metallic Damon brackets, while these values were 187.81(±27.84) and 191.17(±66.68) g for the clear and metallic conventional brackets, respectively. Static frictional forces were 206.4(±42.45) and 210.38(±15.89) g in the esthetic and metallic Damon brackets and 220.63(±49.29) and 215.13(±62.38) g in the clear and metallic conventional brackets. According to two-way ANOVA, no significant difference was observed between the two bracket materials (clear and metal) and the two types of bracket (self-ligating versus conventional) regarding resistance to sliding (p= 0.17 and p= 0.23, respectively) and static frictional forces (p= 0.55 and p= 0.96, respectively). Conclusion Neither the type of bracket materials nor their type of ligation made difference in resistance to sliding and static friction. PMID:26106630

  14. Resistance to Sliding in Clear and Metallic Damon 3 and Conventional Edgewise Brackets: an In vitro Study.

    Science.gov (United States)

    Karim Soltani, Mohammad; Golfeshan, Farzaneh; Alizadeh, Yoones; Mehrzad, Jabraiel

    2015-03-01

    Frictional forces are considered as important counterforce to orthodontic tooth movement. It is claimed that self-ligating brackets reduce the frictional forces. The aim of this study was to compare the resistance to sliding in metallic and clear Damon brackets with the conventional brackets in a wet condition. The samples included 4 types of brackets; metallic and clear Damon brackets and metallic and clear conventional brackets (10 brackets in each group). In this study, stainless steel wires sized 0.019×0.025 were employed and the operator's saliva was used to simulate the conditions of oral cavity. The tidy-modified design was used for simulation of sliding movement. The resistance to sliding and static frictional forces was measured by employing Testometric machine and load cell. The mean (±SD) of resistance to sliding was 194.88 (±26.65) and 226.62 (±39.9) g in the esthetic and metallic Damon brackets, while these values were 187.81(±27.84) and 191.17(±66.68) g for the clear and metallic conventional brackets, respectively. Static frictional forces were 206.4(±42.45) and 210.38(±15.89) g in the esthetic and metallic Damon brackets and 220.63(±49.29) and 215.13(±62.38) g in the clear and metallic conventional brackets. According to two-way ANOVA, no significant difference was observed between the two bracket materials (clear and metal) and the two types of bracket (self-ligating versus conventional) regarding resistance to sliding (p= 0.17 and p= 0.23, respectively) and static frictional forces (p= 0.55 and p= 0.96, respectively). Neither the type of bracket materials nor their type of ligation made difference in resistance to sliding and static friction.

  15. Orthodontic bracket bonding to glazed full-contour zirconia

    Directory of Open Access Journals (Sweden)

    Ji-Young Kwak

    2016-05-01

    Full Text Available Objectives This study evaluated the effects of different surface conditioning methods on the bond strength of orthodontic brackets to glazed full-zirconia surfaces. Materials and Methods Glazed zirconia (except for the control, Zirkonzahn Prettau disc surfaces were pre-treated: PO (control, polishing; BR, bur roughening; PP, cleaning with a prophy cup and pumice; HF, hydrofluoric acid etching; AA, air abrasion with aluminum oxide; CJ, CoJet-Sand. The surfaces were examined using profilometry, scanning electron microscopy, and electron dispersive spectroscopy. A zirconia primer (Z-Prime Plus, Z or a silane primer (Monobond-S, S was then applied to the surfaces, yielding 7 groups (PO-Z, BR-Z, PP-S, HF-S, AA-S, AA-Z, and CJ-S. Metal bracket-bonded specimens were stored in water for 24 hr at 37℃, and thermocycled for 1,000 cycles. Their bond strengths were measured using the wire loop method (n = 10. Results Except for BR, the surface pre-treatments failed to expose the zirconia substructure. A significant difference in bond strengths was found between AA-Z (4.60 ± 1.08 MPa and all other groups (13.38 ± 2.57 - 15.78 ± 2.39 MPa, p < 0.05. For AA-Z, most of the adhesive remained on the bracket. Conclusions For bracket bonding to glazed zirconia, a simple application of silane to the cleaned surface is recommended. A zirconia primer should be used only when the zirconia substructure is definitely exposed.

  16. DEBONDING OF CERAMIC BRACKETS BY ER:YAG LASER

    Directory of Open Access Journals (Sweden)

    Fidan ALAKUŞ-SABUNCUOĞLU

    2016-04-01

    Full Text Available Purpose: The objective of the present study is to evaluate the effects of Er:YAG laser debonding of ceramic brackets on the bond strength and the amount of adhesive resin remnant. Materials and Methods: Twenty human mandibular incisors were randomly divided into two groups of 10 and polycrystalline ceramic brackets (Transcend series 6000, 3M Unitek, Monrovia, CA, USA were bonded on enamel surfaces. Group 1 was the control group in which no laser application was performed prior to the shear bond strength (SBS testing. In Group 2, Er:YAG was applied in 3W power for 6 seconds using the scanning method. The brackets were tested for SBS with an Instron universal testing machine and results were expressed in megapascals (MPa. The amount of adhesive remnant was evaluated with Adhesive Remnant Index (ARI. One-way analysis of variance and Tukey’s post-hoc tests were used for statistical analysis. Results: Mean ± standard deviation of SBS values in the control group was 13.42 ±1.23 MPa and 8.47 ±0.71 MPa in the Er:YAG group and this difference was statistically significant (p<0.05. The evaluation of ARI scores demonstrated more adhesive was left on the enamel surface with Er:YAG group. Conclusion: 3W power Er:YAG laser application with the scanning method to polycrystalline ceramic brackets demonstrated lower bond strengths and higher ARI scores during the debonding procedure.

  17. Comparison of static friction with self-ligating, modified slot design and conventional brackets.

    Science.gov (United States)

    Castro, Raquel Morais; Neto, Perrin Smith; Horta, Martinho Campolina Rebello; Pithon, Matheus Melo; Oliveira, Dauro Douglas

    2013-01-01

    To compare the static frictional forces generated at the bracket/wire interface of stainless steel brackets with different geometries and angulations, combined with orthodontic wires of different diameters. The frictional forces were evaluated with three different types of metal brackets: a passive self-ligating (SmartClipTM, 3M/Unitek, Monrovia, USA), with a modified slot design (Mini Uni TwinTM, 3M/Unitek, Monrovia, USA) and conventional (Kirium, Abzil, São José do Rio Preto, Brazil). The samples were mounted in a testing device with three different angulations and tested with 0.014" and 0.018" stainless steel wires (American Orthodontics, Sheboygan, USA). The static frictional force was measured using a universal testing machine (DL 500, EMIC®, São José dos Pinhais, Brazil) with a crosshead speed of 1 mm/min. Statistical analysis was performed by two-way ANOVA followed by Bonferroni's post hoc test. There was a significant difference (pstatic friction when the three types of brackets were tested with the same wire size. The wire diameter influenced friction only when the brackets had a 10º angulation (pfriction (pstatic frictional force values between the conventional and self-ligating brackets tested.

  18. In vitro evaluation of microleakage under orthodontic brackets bonded with different adhesive systems.

    Science.gov (United States)

    Atash, Ramin; Fneiche, Ali; Cetik, Sibel; Bahrami, Babak; Balon-Perin, Alain; Orellana, Maria; Glineur, Régine

    2017-01-01

    Adhesives systems have a drawback when utilized for bonding orthodontic brackets: they shrink during photopolymerization creating microleakage. The aim of this study was to assess the stability of different orthodontic adhesives around brackets and enamel. Sixty noncarious mandibular premolars extracted for orthodontic reasons were randomly divided into six groups of adhesives used for bonding brackets to dental enamel: NeoBond ® Light Cure Adhesive Kit, Transbond™ Plus Self-Etching, Victory V-Slot APC PLUS ® + Transbond™ MIP, Rely-A-Bond ® Kit, Light Cure Orthodontic Adhesive Kit (OptiBond ® ), and Transbond™ MIP. Following bonding, all teeth underwent 2500 cycles of thermal cycling in baths ranging from 5°C to 55°C before being immersed in 2% methylene blue for 24 h. All samples were examined under a binocular microscope to assess the degree of microleakage at the "bracket-adhesive" and "adhesive-enamel" interfaces in the gingival and occlusal regions of the bracket. A significant difference was found at the "occlusal bracket-adhesive" interface. The highest microleakage values were found in the occlusal region, although no significant. Microleakage was observed in all groups. Group 2 had the highest microleakage values whereas Group 6 had the lowest values.

  19. Mechanical and topographic evaluation of esthetic brackets and its relation to frictional resistance

    Directory of Open Access Journals (Sweden)

    Vikram Pai

    2013-01-01

    Full Text Available Introduction: The purpose of this in-vitro study was to evaluate the frictional characteristics of conventional ceramic versus metal insert ceramic brackets in combination with stainless steel and Teflon-coated stainless steel archwires. Materials and Methods: Twenty brackets each, of ceramic and metal insert ceramic Maxillary canine preadjusted edgewise brackets 0.022 × 0.028 in slot and 20 archwires, each of stainless steel and Teflon-coated stainless steel (0.019 × 0.025 in were tested for frictional resistance. Friction was evaluated in a simulated Tidy′s design apparatus on universal testing machine. The kinetic friction data were analyzed using Student′s ′t′ test. The effects of surface characteristics on frictional resistance were qualitatively assessed using scanning electron microscope. Results: Metal insert ceramic brackets generated significantly lower kinetic frictional resistance than the conventional ceramic brackets with Teflon-coated stainless steel archwires (P < 0.001 as well as stainless steel archwires (P < 0.05. Conclusion: Metal insert ceramic bracket with stainless steel archwire is the best possible combination among the materials studied because it generated the least frictional resistance during simulated tooth movement.

  20. Surface modification for bonding between amalgam and orthodontic brackets.

    Science.gov (United States)

    Wongsamut, Wittawat; Satrawaha, Sirichom; Wayakanon, Kornchanok

    2017-01-01

    Testing of methods to enhance the shear bond strength (SBS) between orthodontic metal brackets and amalgam by sandblasting and different primers. Three hundred samples of amalgam restorations (KerrAlloy ® ) were prepared in self-cured acrylic blocks, polished, and divided into two groups: nonsandblasted and sandblasted. Each group was divided into five subgroups with different primers used in surface treatment methods, with a control group of bonded brackets on human mandibular incisors. Following the surface treatments, mandibular incisor brackets (Unitek ® ) were bonded on the amalgam with adhesive resin (Transbond XT ® ). The SBS of the samples was tested. The adhesive remnant index (ARI) and failure modes were then determined under a stereo-microscope. Two-way analysis of variance, Chi-square, and Kruskal-Wallis tests were performed to calculate the correlations between and among the SBS and ARI values, the failure modes, and surface roughness results. There were statistically significant differences of SBS among the different adhesive primers and sandblasting methods ( P 0.05). Using adhesive primers with sandblasting together effectively enhances the SBS between orthodontic metal brackets and amalgam. The two primers with the ingredient methacryloxydecyl dihydrogen phosphate (MDP) monomer, Alloy Primer ® and Assure Plus ® , were the most effective. Including sandblasting in the treatment is essential to achieve the bonding strength required.

  1. The effects of silver coating on friction coefficient and shear bond strength of steel orthodontic brackets.

    Science.gov (United States)

    Arash, Valiollah; Anoush, Keivan; Rabiee, Sayed Mahmood; Rahmatei, Manuchehr; Tavanafar, Saeid

    2015-01-01

    Aims of the present study was to measure frictional resistance between silver coated brackets and different types of arch wires, and shear bond strength of these brackets to the tooth. In an experimental clinical research 28 orthodontic brackets (standard, 22 slots) were coated with silver ions using electroplate method. Six brackets (coated: 3, uncoated: 3) were evaluated with Scanning Electron Microscopy and Atomic Force Microscopy. The amount of friction in 15 coated brackets was measured with three different kinds of arch wires (0.019 × 0.025-in stainless steel [SS], 0.018-in stainless steel [SS], 0.018-in Nickel-Titanium [Ni-Ti]) and compared with 15 uncoated steel brackets. In addition, shear bond strength values were compared between 10 brackets with silver coating and 10 regular brackets. Universal testing machine was used to measure shear bond strength and the amount of friction between the wires and brackets. SPSS 18 was used for data analysis with t-test. SEM and AFM results showed deposition of a uniform layer of silver, measuring 8-10 μm in thickness on bracket surfaces. Silver coating led to higher frictional forces in all the three types of arch wires, which was statistically significant in 0.019 × 0.025-in SS and 0.018-in Ni-Ti, but it did not change the shear bond strength significantly. Silver coating with electroplating method did not affect the bond strength of the bracket to enamel; in addition, it was not an effective method for decreasing friction in sliding mechanics. © Wiley Periodicals, Inc.

  2. A Comparison of Traditional and Self-Control Desensitization.

    Science.gov (United States)

    Deffenbacher, Jerry L.; Parks, Donald H.

    1979-01-01

    Compared effectiveness of counterconditioning and self-control models of systematic desensitization in reducing targeted and nontargeted anxieties. Treatments were equally effective in reducing and maintaining reduction of targeted anxiety, debilitating test anxiety. (Author)

  3. An in vitro Evaluation of Shear Bond Strength of Adhesive Precoated Brackets

    Directory of Open Access Journals (Sweden)

    A S Sibi

    2014-01-01

    Full Text Available Newer materials have been introduced in the field of orthodontics to improve clinical efficacy as well as to simplify the technique. In an effort to reduce the time and steps to bond orthodontic attachments, adhesive precoated (APC brackets were introduced. In this study, an attempt is made to evaluate the shear bond strength (SBS and debonding behavior of APC brackets compared with uncoated ceramic brackets. A total of 60 human premolar teeth were divided into two groups of 30 each, bonded with APC ceramic brackets and uncoated ceramic brackets. Group I bonded with APC brackets as prescribed by the manufacturers and group II was bonded with conventional bonding using Turbobond. After bonding, sthe samples were kept in distilled water at 37°C for 24 hours and a universal testing mechine was used to apply an occlusal shear force at a speed of 0.5 mm/min. The shear bond strength of the groups was compared using Student t-test and the debonding behavior were compared using Mann-Whitney′s U test. Mean shear bond strength and standard deviation of the groups were group I - 9.09 ± 2.5 MPa and group II - 12.95 ± 2.81 MPa. There were significant differences in bond strength observed between the two groups. The debonding behavior showed an adhesive remnant index score of 0.90 ± 0.08 for group I and 1.10 ± 0.04 for group II, which indicates there is significant difference between each other. When considering the values required for optimum bond strength, APC brackets in this study showed adequate bond strength and could be used for routine clinical use.

  4. Changes in the surface roughness and friction coefficient of orthodontic bracket slots before and after treatment.

    Science.gov (United States)

    Liu, Xiaomo; Lin, Jiuxiang; Ding, Peng

    2013-01-01

    In this study, we tested the surface roughness of bracket slots and the friction coefficient between the bracket and the stainless steel archwire before and after orthodontic treatment. There were four experimental groups: groups 1 and 2 were 3M new and retrieved brackets, respectively, and groups 3 and 4 were BioQuick new and retrieved brackets, respectively. All retrieved brackets were taken from patients with the first premolar extraction and using sliding mechanics to close the extraction space. The surface roughness of specimens was evaluated using an optical interferometry profilometer, which is faster and nondestructive compared with a stylus profilometer, and provided a larger field, needing no sample preparation, compared with atomic force microscopy. Orthodontic treatment resulted in significant increases in surface roughness and coefficient of friction for both brands of brackets. However, there was no significant difference by brand for new or retrieved brackets. These retrieval analysis results highlight the necessity of reevaluating the properties and clinical behavior of brackets during treatment to make appropriate treatment decisions. © Wiley Periodicals, Inc.

  5. A Comparison of Implosive Therapy and Systematic Desensitization in the Treatment of Test Anxiety

    Science.gov (United States)

    Smith, Ronald E.; Nye, S. Lee

    1973-01-01

    Both Desensitization and implosive therapy resulted in significant decreases in scores on Sarason's Test Anxiety Scale. However, the desensitization group also demonstrated a significant reduction in state anxiety assessed during simulated testing sessions and a significant increase in grade point average, while the implosive therapy group showed…

  6. Specific oral desensitization in children with IgE-mediated cow's milk allergy. Evolution in one year.

    Science.gov (United States)

    Alvaro, Montserrat; Giner, Ma Teresa; Vázquez, Marta; Lozano, Jaime; Domínguez, Olga; Piquer, Mónica; Días, Marcia; Jiménez, Rosa; Martín, Ma Anunciación; Alsina, Laia; Plaza, Ana Ma

    2012-09-01

    Cow's milk allergy is the most frequent childhood food allergy. Children older than 5 who have not become tolerant have less probabilities of natural tolerance. Specific oral desensitization methods are being investigated in reference centres. The aims of our study were to assess the efficacy of our guideline of specific oral desensitization to cow's milk in children and to know its suitability for anaphylactic children. Both clinical and specific IgE outcomes were evaluated. Eighty-seven children aged 5 to 16 years with a history of cow's milk allergy were included. Prior to desensitization, skin prick test, specific IgE to cow's milk proteins and a double-blind placebo control food challenge were performed in all. Of the 87 patients, 21 had a negative challenge; they were considered tolerant, and they were told to follow a free diet. Of the positive, 44 were anaphylactic and 22 non-anaphylactic. All of them were included. In non-anaphylactic patients, 6 achieved partial and 16 maximum desensitization after 23.1 weeks. In the anaphylactic group, 7 achieved partial and 35 maximum desensitization after 26.4 weeks. Cow's milk-specific IgE levels and casein-specific IgE levels were significantly lower in the tolerant patients at baseline. One year after desensitization, the medium specific cow's milk levels and casein IgE levels had dropped significantly. Our guideline for specific oral desensitization to cow's milk is efficacious even in patients with anaphylactic reactions to cow's milk and represents a significant life change. Immunological changes in 1 year show a drop in cow's milk protein-specific IgE.

  7. Forces in the presence of ceramic versus stainless steel brackets with unconventional vs conventional ligatures.

    Science.gov (United States)

    Baccetti, Tiziano; Franchi, Lorenzo; Camporesi, Matteo

    2008-01-01

    To compare the forces resulting from four types of bracket/ligature combinations: ceramic brackets and stainless steel brackets combined with unconventional elastomeric ligatures (UEL) and conventional elastomeric ligatures (CEL) during the leveling and aligning phases of orthodontic therapy. The testing model consisted of five 0.022-inch preadjusted brackets (second premolar, first premolar, canine, lateral incisor, and central incisor) for each of the two bracket types. The canine bracket was welded to a sliding bar that allowed for different amounts of offset in the gingival direction. The forces generated by a 0.014-inch superelastic nickel titanium wire in the presence of either the UEL or CEL bracket/ligature systems at different amounts of upward canine misalignment (1.5 mm, 3 mm, 4.5 mm, and 6 mm) were recorded. Significant differences were found between UEL and CEL systems for all tested variables (P < .01) with the exception of the canine misalignment of 1.5 mm. The average amount of recorded force in the presence of CEL was negligible with 3.0 mm or greater of canine misalignment. On the contrary, during alignment, a force available for tooth movement was recorded in the presence of both ceramic and stainless steel brackets when associated with UEL. The type of ligature used influenced the actual amount of force released by the orthodontic system significantly more than the type of bracket used (stainless steel vs ceramic).

  8. Effect of Different Bleaching Techniques on Microleakage under orthodontic Brackets: In Vitro Study

    Directory of Open Access Journals (Sweden)

    Salehi P

    2018-03-01

    Full Text Available Statement of problem: Numerous studies report significant changes in tooth color that occur during orthodontic treatment. The adverse effects of bleaching procedures during orthodontic treatments have not been studied comprehensively. Objectives: This study investigated the effects of two methods of dental bleaching on the degree of microleakage beneath orthodontic brackets. Materials and Methods: We selected 45 extracted premolar teeth and bonded them to orthodontic brackets. These teeth were stored in normal saline for 24 hours and thermocycled. We randomly divided the samples into 3 groups of 15 teeth per group. The first group (control received no bleach treatment; the second group (office bleaching was treated with 35% hydrogen peroxide (Whiteness HP Maxx; and the third group (home bleaching was treated with 22% carbamide peroxide (Whiteness Perfect. The apices were sealed with sticky wax, rinsed in tap water, and air-dried. We applied nail varnish to the entire surface of each tooth, except for an area approximately 1 mm away from the brackets. The samples were immersed in basic fuchsine and cleaned after 24 hours. Microleakage was determined by direct measurement using a stereomicroscope. Kruskal-Wallis and Dunn post-hoc statistical tests, and SPSS software were used for statistical analysis. The significance level was set at P≤0.05. Results: The office bleaching group had significantly more microleakage scores under the brackets at both the occlusal (P=0.04 and gingival (P =0.040 margins of the brackets compared to the home bleaching group. The home bleaching group showed statistically more significant microleakage scores than the control group in both the gingival (P=0.006 and occlusal (P=0.014 margins of the brackets. All three groups had statistically more significant microleakage at the gingival margins of the brackets than the occlusal margins. Conclusions: Office bleaching caused the most microleakage under the brackets and home

  9. Forces produced by different nonconventional bracket or ligature systems during alignment of apically displaced teeth.

    Science.gov (United States)

    Baccetti, Tiziano; Franchi, Lorenzo; Camporesi, Matteo; Defraia, Efisio; Barbato, Ersilia

    2009-05-01

    To analyze the forces released by four types of passive stainless steel self-ligating brackets (SLBs), and by two nonconventional elastomeric ligature-bracket systems when compared with conventional elastomeric ligatures on conventional stainless steel brackets during the alignment of apically displaced teeth at the maxillary arch. An experimental model consisting of five brackets was used to assess the forces released by the seven different ligature-bracket systems with 0.012'' or 0.014'' superelastic nickel titanium wire in the presence of different amounts of apical displacement of the canine (ranging from 1.5 mm to 6 mm). Comparisons between the different types of bracket/wire/ ligature systems were carried out by means of ANOVA on ranks with Dunnett's post hoc test (P < .05). When correction of a misalignment greater than 3 mm is attempted, a noticeable amount of force for alignment is generated by passive SLBs and nonconventional elastomeric ligature-bracket systems, and a null amount of force is released in the presence of conventional elastomeric ligatures on conventional brackets. When minimal apical displacement is needed (1.5 mm), the differences in performance between low-friction and conventional systems are minimal. These differences become significant when correction of a misalignment of greater than 3.0 mm is attempted.

  10. The Effects of In-Office Reconditioning on the Slot Dimensions and Static Frictional Resistance of Stainless Steel Brackets.

    Science.gov (United States)

    Iluru, Rohini; Nellore, Chaitanya; Karnati, Praveen Kumar Reddy; Thalapaneni, Ashok Kumar; Myla, Vijay Bhaskar; Ramyasree, Konda; Prasad, Mandava

    2016-01-01

    Orthodontists are commonly faced with the decision of what to do with loose brackets, and with inaccurately located brackets that need repositioning during treatment. One solution is to recycle the brackets. The potential effects of reconditioning a bracket are dependent upon many factors which may result in physical changes like alteration in slot tolerance, which may influence sliding mechanics by affecting frictional resistance. To study and compare the dimensional changes in the bracket slot width and depth in reconditioned brackets from unused brackets under scanning electronic microscope and to study and compare any consequent effects on the static frictional resistance of stainless steel brackets after reconditioning and in unused brackets. Dentarum manufactured 90 stainless steel central incisors edgewise brackets of size 0.22 X 0.030″ inch and 0° tip and 0°angulation were taken. 60 samples for measuring frictional resistance and 30 samples for measuring slot dimensions. Ortho organizers manufactured stainless steel arch wires 0.019 X 0.025″ straight lengths 60 in number were considered for measuring static frictional resistance. The mean slot width and depth of new brackets were 0.0251″ and 0.0471″, which exceeded the manufacturers reported nominal size of 0.022″ X 0.030″, by 0.003″ and 0.017″. The reconditioned brackets demonstrated a further increase in mean slot width and depth to 0.028″ and 0.0518″ that is by 0.0035″ and 0.0047″ which is statistically significant (p=0.001, 0.002). The mean static frictional forces of the reconditioned brackets was nearly similar to that of new brackets that is 0.3167N for reconditioned brackets and 0.2613 N for new brackets. Although the reconditioning process results in physical changes to bracket structure this does not appear to result in significant effect on ex-vivo static frictional resistance.

  11. Early aspirin desensitization in unstable patients with acute coronary syndrome: Short and long-term efficacy and safety.

    Science.gov (United States)

    Córdoba-Soriano, Juan Gabriel; Corbí-Pascual, Miguel; López-Neyra, Isabel; Navarro-Cuartero, Javier; Hidalgo-Olivares, Víctor; Barrionuevo-Sánchez, Maria Isabel; Prieto-Mateos, Daniel; Gutiérrez-Díez, Antonio; Gallardo-López, Arsenio; Fuentes-Manso, Raquel; Gómez-Pérez, Alberto; Lafuente-Gormaz, Carlos; Jiménez-Mazuecos, Jesús

    2016-11-01

    Aspirin hypersensitivity is not a rare condition among patients with acute coronary syndrome. However, despite the publication of several successful desensitization protocols, the procedure is not as widespread as expected. We present a cohort of patients with acute coronary syndrome undergoing aspirin desensitization to evaluate its short- and long-term efficacy and safety and to reinforce data from previous studies. Of 1306 patients admitted to our Coronary Care Unit between February 2011 and February 2013, 24 (1.8%) had a history of aspirin hypersensitivity. All 24 patients underwent an eight-dose aspirin desensitization protocol (0.1, 0.3, 1, 3, 10, 25, 50 and 100 mg of aspirin given by mouth every 15 minutes) after premedication with antihistamines and corticosteroids or antileucotrienes. Previously prescribed β blockers and angiotensin-converting enzyme inhibitors were not discontinued. All patients were desensitized within 72 hours of admission. Those requiring urgent catheterization (five patients with ST segment elevation myocardial infarction) were desensitized within 12 hours of catheterization and the remainder before catheterization. All patients were successfully desensitized and only one presented with an urticarial reaction. The five patients with ST segment elevation myocardial infarction were treated with abciximab until desensitization was complete. All but one patient underwent catheterization and 20 underwent percutaneous coronary intervention, most (66%) with the implantation of a bare metal stent. At follow-up (a minimum of 6-24 months), only two patients had discontinued aspirin, both due to gastrointestinal bleeding, and no hypersensitivy reaction had occurred. Aspirin desensitization is effective and safe in unstable patients with acute coronary syndrome in both the short and long term.

  12. Antimicrobial action of chlorhexidine digluconate in self-ligating and conventional metal brackets infected with Streptococcus mutans biofilm.

    Science.gov (United States)

    Dias, Ana Paula; Paschoal, Marco Aurélio Benini; Diniz, Rafael Soares; Lage, Lucas Meneses; Gonçalves, Letícia Machado

    2018-01-01

    The objectives of this study were to assess the adherence of Streptococcus mutans biofilms grown over conventional ligature (CL) or self-ligating (SL) metal brackets and their bacterial viability after 0.12% chlorhexidine (CHX) digluconate treatment. The sample consisted of 48 metallic orthodontic brackets divided randomly into two groups: CL (n=24) and SL brackets (n=24). S. mutans biofilms were grown over the bracket surface (96 h) and treated with CHX (positive control) or 0.9% phosphate-buffered saline (PBS) (negative control) for 1 min each. Quantitative analysis was assessed by colony-forming units, and fluorescence microscopy was performed aiming to illustrate the outcomes. The tests were done in triplicate at three different times (n=9). Data were analyzed using ANOVA and Tukey test ( P brackets' biofilm formation, being CL largely colonized compared with SL, which was observed by colony-forming unit counting ( P brackets treated with CHX compared to PBS ( P brackets ( P >0.05). In conclusion, a lower colonization was achieved in SL brackets and S. mutans biofilms were susceptible to CHX treatment to both studied brackets.

  13. Self-ligating versus conventional metallic brackets on Streptococcus mutans retention: A systematic review.

    Science.gov (United States)

    Longoni, Juliano N; Lopes, Beatriz M; Freires, Irlan A; Dutra, Kamile L; Franco, Ademir; Paranhos, Luiz R

    2017-01-01

    The present study aimed to review the literature systematically and assess comparatively whether self-ligating metallic brackets accumulate less Streptococcus mutans biofilm than conventional metallic brackets. The systematic search was performed following PRISMA guidelines and registration in PROSPERO. Seven electronic databases (Google Scholar, LILACS, Open Grey, PubMed, SciELO, ScienceDirect, and Scopus) were consulted until April 2016, with no restriction of language and time of publication. Only randomized clinical studies verifying S. mutans colonization in metallic brackets (self-ligating and conventional) were included. All steps were performed independently by two operators. The search resulted in 546 records obtained from the electronic databases. Additionally, 216 references obtained from the manual search of eligible articles were assessed. Finally, a total of 5 studies were included in the qualitative synthesis. In 1 study, the total bacterial count was not different among self-ligating and conventional brackets, whereas in 2 studies the amount was lower for self-ligating brackets. Regarding the specific count of S. mutans , 2 studies showed less accumulation in self-ligating than in conventional brackets. Based on the limited evidence, self-ligating metallic brackets accumulate less S. mutans than conventional ones. However, these findings must be interpreted in conjunction with particularities individual for each patient - such as hygiene and dietary habits, which are components of the multifactorial environment that enables S. Mutans to proliferate and keep retained in the oral cavity.

  14. Effect of blood contamination on shear bond strength of orthodontic brackets and disinclusion buttons.

    Science.gov (United States)

    Sfondrini, Maria Francesca; Gatti, Sara; Scribante, Andrea

    2011-07-01

    Our aim was to assess the effect of blood contamination on the shear bonding strength and sites of failure of orthodontic brackets and bondable buttons. We randomly divided 160 bovine permanent mandibular incisors into 8 groups of 20 specimens each. Both orthodontic brackets (Step brackets, Leone, Sesto Fiorentino, Italy) and bondable buttons (Flat orthodontic buttons, Leone, Sesto Fiorentino, Italy) were tested on four different enamel surfaces: dry; contamination with blood before priming; after priming; and before and after priming. Brackets and buttons were bonded to the teeth and subsequently tested using a Instron universal testing machine. Shear bonding strength and the rate of adhesive failures were recorded. Data were analysed using the analysis of variance (ANOVA), Scheffè tests, and the chi-square test. Uncontaminated enamel surfaces showed the highest bonding strengths for both brackets and buttons. When they were contaminated with blood, orthodontic brackets had significantly lower shear strengths than bondable buttons (P=0.0001). There were significant differences in sites of failure among the groups for the various enamel surfaces (P=0.001). Contamination of enamel by blood during bonding lowers the strength of the bond, more so with orthodontic brackets than with bondable buttons. Copyright © 2010 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  15. Effects of green tea on the shear bond strength of orthodontic brackets after in-office vital bleaching.

    Science.gov (United States)

    Berger, Sandrine Bittencourt; Guiraldo, Ricardo Danil; Lopes, Murilo Baena; Oltramari-Navarro, Paula Vanessa; Fernandes, Thais Maria; Schwertner, Renata de Castro Alves; Ursi, Wagner José Silva

    2016-01-01

    The application of bleaching agents before placement of resin-bonded fixed appliances significantly, but temporarily, reduces bond strength to tooth structure. Antioxidants have been studied as a means to remove residual oxygen that compromises bonding to bleached enamel. This in vitro study evaluated whether green tea (GT) could restore the shear bond strength between bonded orthodontic brackets and bleached enamel. Six experimental groups were compared: group 1, no bleaching plus bracket bonding (positive control); group 2, bleaching with 35% hydrogen peroxide (HP) plus bracket bonding (negative control); group 3, 35% HP plus 10% sodium ascorbate (SA) plus bracket bonding; group 4, 35% HP plus 10% GT plus bracket bonding; group 5, no bleaching plus 10% SA plus bracket bonding; group 6, no bleaching plus 10% GT plus bracket bonding. Results suggested that GT, like SA, may be beneficial for bracket bonding immediately after bleaching.

  16. Evaluating the Type of Light Transmittance in Mono Crystalline, Poly Crystalline and Sapphire Brackets- An Invitro Spectrofluorometer Study.

    Science.gov (United States)

    Mohamed, Jauhar P; Kommi, Pradeep Babu; Kumar, M Senthil; Hanumanth; Venkatesan; Aniruddh; Arvinth; Kumar, Arani Nanda

    2016-08-01

    Most of the patients seek orthodontic treatment to improve the smile, which improves the facial profile by means of fixed appliances i.e., brackets and wires. The brackets are of different types like stainless steel and ceramic. Ceramic brackets were considered as aesthetic appliance which was divided into mono-crystalline, polycrystalline and sapphire brackets. The light transmittance might influence the degree of curing adhesive material in mono crystalline, polycrystalline and sapphire brackets. The aim of the present study was to evaluate the translucency and intensity of three different aesthetic brackets (mono crystalline, poly crystalline and sapphire ceramic brackets) and to determine their influence on shear bond strength of the brackets. The adhesive remnant index was also measured after debonding of the brackets from the tooth surface. Twenty six samples each of monocrystalline, polycrystalline and sapphire brackets (total 78 ceramic brackets) were used for the study. The bracket samples were subjected to optical fluorescence test using spectrofluorometer to measure the intensity of the brackets. Seventy eight extracted premolar teeth were procured and divided into 3 groups. The brackets were then bonded to the tooth using Transbond XT (3M Unitek) light cure composite material and cured with new light cure unit (Light Emitting Diode) of wood pecker company (400-450nm) for 30 seconds, and these samples were subjected to shear bond strength test with Instron Universal Testing Machine (UNITEK-94100) with a load range between 0 to 100 KN with a maximum cross head speed of 0.5mm/min. ARI (Adhesive Remnant Index) scores were evaluated according to Artun and Bergland scoring system using stereomicroscope at 20x magnification. The light absorption values obtained from spectrofluorometeric study were 3300000-3500000 cps for group 1 (monocrystalline ceramic brackets), 6000000-6500000 cps for Group 2 (polycrystalline ceramic brackets) and 2700000 -3000000 cps for

  17. Galvanic Corrosion of and Ion Release from Various Orthodontic Brackets and Wires in a Fluoride-containing Mouthwash.

    Science.gov (United States)

    Tahmasbi, Soodeh; Ghorbani, Mohammad; Masudrad, Mahdis

    2015-01-01

    Background and aims. This study compared the galvanic corrosion of orthodontic wires and brackets from various manufacturers following exposure to a fluoride mouthwash. Materials and methods. This study was conducted on 24 lower central incisor 0.022" Roth brackets of four different commercially available brands (Dentaurum, American Orthodontics, ORJ, Shinye). These brackets along with stainless steel (SS) or nickel-titanium (NiTi) orthodontic wires (0.016", round) were immersed in Oral-B mouthwash containing 0.05% sodium fluoride for 28 days. The electric potential (EP) difference of each bracket-wire couple was measured with a Saturated Calomel Reference Electrode (Ag/AgCl saturated with KCl) via a voltmeter. The ions released in the electrolyte weremeasured with an atomic absorption spectrometer. All the specimens were assessed under a stereomicroscope and specimens with corrosion were analyzed with scanning electron microscopy (SEM). Data were analyzed using ANOVA. Results. The copper ions released from specimens with NiTi wire were greater than those of samples containing SS wire. ORJ brackets released more Cu ions than other samples. The Ni ions released from Shinye brackets were significantly more than those of other specimens (P brackets coupled with NiTi wires was higher than that of brackets coupled with SS wires. Light and electron microscopic observations showed greater corrosion of ORJ brackets. Conclusion. In fluoride mouthwash, Shinye and ORJ brackets exhibited greater corrosion than Dentaurum and American Orthodontics brackets. Stainless steel brackets used with NiTi wires showed greater corrosion and thus caution is recommended when using them.

  18. Desensitization And Study-Skills Training As Treatment For Two Types of Test-Anxious Students

    Science.gov (United States)

    Osterhouse, Robert A.

    1972-01-01

    This study compared the effectiveness of systematic desensitization and training in efficient study methods for reducing test anxiety among subjects selected on the basis of two types of self reported anxiety. Desensitization offered more promise as a treatment method for test anxiety than did training in study skills. (Author)

  19. AMPA receptor mediated excitotoxicity in neocortical neurons is developmentally regulated and dependent upon receptor desensitization

    DEFF Research Database (Denmark)

    Jensen, J B; Schousboe, A; Pickering, D S

    1998-01-01

    with a fast and rapidly desensitizing response, this could explain the relatively low toxicity produced by 500 microM AMPA. This was investigated by blocking AMPA receptor desensitization with cyclothiazide. Using a lower concentration (25 microM) of AMPA, addition of 50 microM cyclothiazide increased...... the AMPA induced excitotoxicity in cultured cortical neurons at all DIV except for DIV 2. This combination of AMPA + cyclothiazide yielded 77% cell death for DIV 12 cultures. In contrast to the results observed with 500 microM AMPA, the neurotoxicity mediated directly by AMPA receptors when desensitization...

  20. Effect of saliva contamination on cementation of orthodontic brackets using different adhesive systems.

    Science.gov (United States)

    Robaski, Aliden-Willian; Pamato, Saulo; Tomás-de Oliveira, Marcelo; Pereira, Jefferson-Ricardo

    2017-07-01

    The enamel condition and the quality of surface are points that need to be considered for achieving optimal efficiency in the treatment with orthodontic brackets. The aim of this study was to assess the immediate bond strength of metallic brackets cemented to dental. Forty human premolars were double-sectioned, placed in PVC matrices and randomly divided into 10 groups (n=8). They received artificial saliva contamination before or after the application of adhesive systems, except for the control groups. The metallic brackets were cemented using two orthodontic cements (Transbond™ Plus Color Change, 3M Unitek e Transbond™ XT Light, 3M Unitek). The specimens were subjected to mechanical shear bond strength testing and classified according to the fracture pattern. The results were analyzed using a two-way ANOVA and Tukey's test for multiple comparisons ( p brackets cemented on the dental enamel. Key words: Bonding, orthodontic brackets, shear bond strength, saliva, adhesive systems.

  1. Evaluation of Static Friction of Polycrystalline Ceramic Brackets after Conditioning with Different Powers of Er:YAG Laser.

    Science.gov (United States)

    Arash, Valiollah; Javanmard, Saeed; Eftekhari, Zeinab; Rahmati-Kamel, Manouchehr; Bahadoram, Mohammad

    2015-01-01

    This research aimed to reduce the friction between the wire and brackets by Er:YAG laser. To measure the friction between the wires and brackets in 0° and 10° of wire angulations, 40 polycrystalline ceramic brackets (Hubit, South Korea) were divided into 8 study groups and irradiated by 100, 200, and 300 mj/s of Er:YAG laser power. Two groups of brackets were not irradiated. The friction between the wires and brackets was measured with universal testing machine (SANTAM) with a segment of .019 × .025 SS wire pulled out of the slot of bracket. ANOVA and t-test were used for analyzing the results. To evaluate the effect of the laser on surface morphology of the bracket, SEM evaluations were carried out. The mean frictional resistances between the brackets and wires with 0° of angulation by increasing the laser power decreased compared with control group, but, in 10° of angulation, the friction increased regardless of the laser power and was comparable to the friction of nonirradiated brackets. Furthermore, with each laser power, frictional resistance of brackets in 10° of angulation was significantly higher than 0° of angulation. These results were explained by SEM images too.

  2. Characterising the mechanism of airway smooth muscle β2 adrenoceptor desensitization by rhinovirus infected bronchial epithelial cells.

    Directory of Open Access Journals (Sweden)

    David Van Ly

    Full Text Available Rhinovirus (RV infections account for approximately two thirds of all virus-induced asthma exacerbations and often result in an impaired response to β2 agonist therapy. Using an in vitro model of RV infection, we investigated the mechanisms underlying RV-induced β2 adrenoceptor desensitization in primary human airway smooth muscle cells (ASMC. RV infection of primary human bronchial epithelial cells (HBEC for 24 hours produced conditioned medium that caused β2 adrenoceptor desensitization on ASMCs without an effect on ASMCs viability. Less than 3 kDa size fractionation together with trypsin digestion of RV-induced conditioned medium did not prevent β2 adrenoceptor desensitization, suggesting it could potentially be mediated by a small peptide or lipid. RV infection of BECs, ASMCs and fibroblasts produced prostaglandins, of which PGE2, PGF2α and PGI2 had the ability to cause β2 adrenoceptor desensitization on ASMCs. RV-induced conditioned medium from HBECs depleted of PGE2 did not prevent ASMC β2 adrenoceptor desensitization; however this medium induced PGE2 from ASMCs, suggesting that autocrine prostaglandin production may be responsible. Using inhibitors of cyclooxygenase and prostaglandin receptor antagonists, we found that β2 adrenoceptor desensitization was mediated through ASMC derived COX-2 induced prostaglandins. Since ASMC prostaglandin production is unlikely to be caused by RV-induced epithelial derived proteins or lipids we next investigated activation of toll-like receptors (TLR by viral RNA. The combination of TLR agonists poly I:C and imiquimod induced PGE2 and β2 adrenoceptor desensitization on ASMC as did the RNA extracted from RV-induced conditioned medium. Viral RNA but not epithelial RNA caused β2 adrenoceptor desensitization confirming that viral RNA and not endogenous human RNA was responsible. It was deduced that the mechanism by which β2 adrenoceptor desensitization occurs was by pattern recognition receptor

  3. Process qualification and testing of LENS deposited AY1E0125 D-bottle brackets

    International Nuclear Information System (INIS)

    Atwood, Clinton J.; Smugeresky, John E.; Jew, Michael; Gill, David Dennis; Scheffel, Simon

    2006-01-01

    The LENS Qualification team had the goal of performing a process qualification for the Laser Engineered Net Shaping(trademark)(LENS(reg s ign)) process. Process Qualification requires that a part be selected for process demonstration. The AY1E0125 D-Bottle Bracket from the W80-3 was selected for this work. The repeatability of the LENS process was baselined to determine process parameters. Six D-Bottle brackets were deposited using LENS, machined to final dimensions, and tested in comparison to conventionally processed brackets. The tests, taken from ES1E0003, included a mass analysis and structural dynamic testing including free-free and assembly-level modal tests, and Haversine shock tests. The LENS brackets performed with very similar characteristics to the conventionally processed brackets. Based on the results of the testing, it was concluded that the performance of the brackets made them eligible for parallel path testing in subsystem level tests. The testing results and process rigor qualified the LENS process as detailed in EER200638525A

  4. Adhesives for fixed orthodontic brackets.

    Science.gov (United States)

    Mandall, Nicky A; Hickman, Joy; Macfarlane, Tatiana V; Mattick, Rye Cr; Millett, Declan T; Worthington, Helen V

    2018-04-09

    Bonding of orthodontic brackets to teeth is important to enable effective and efficient treatment with fixed appliances. The problem is bracket failure during treatment which increases operator chairside time and lengthens treatment time. A prolonged treatment is likely to increase the oral health risks of orthodontic treatment with fixed appliances one of which is irreversible enamel decalcification. This is an update of the Cochrane Review first published in 2003. A new full search was conducted on 26 September 2017 but no new studies were identified. We have only updated the search methods section in this new version. The conclusions of this Cochrane Review remain the same. To evaluate the effects of different orthodontic adhesives for bonding. Cochrane Oral Health's Information Specialist searched the following databases: Cochrane Oral Health's Trials Register (to 26 September 2017), the Cochrane Central Register of Controlled Trials (CENTRAL; 2017, Issue 8) in the Cochrane Library (searched 26 September 2017), MEDLINE Ovid (1946 to 26 September 2017), and Embase Ovid (1980 to 26 September 2017). The US National Institutes of Health Ongoing Trials Register (ClinicalTrials.gov) and the World Health Organization International Clinical Trials Registry Platform were searched for ongoing trials. No restrictions were placed on the language or date of publication when searching the electronic databases. Trials were selected if they met the following criteria: randomised controlled trials (RCTs) and controlled clinical trials (CCTs) comparing two different adhesive groups. Participants were patients with fixed orthodontic appliances. The interventions were adhesives that bonded stainless steel brackets to all teeth except the molars. The primary outcome was debond or bracket failure. Data were recorded on decalcification as a secondary outcome, if present. Information regarding methods, participants, interventions, outcome measures and results were extracted in

  5. Antibody Desensitization Therapy in Highly Sensitized Lung Transplant Candidates

    Science.gov (United States)

    Snyder, L. D.; Gray, A. L.; Reynolds, J. M.; Arepally, G. M.; Bedoya, A.; Hartwig, M. G.; Davis, R. D.; Lopes, K. E.; Wegner, W. E.; Chen, D. F.; Palmer, S. M.

    2015-01-01

    As HLAs antibody detection technology has evolved, there is now detailed HLA antibody information available on prospective transplant recipients. Determining single antigen antibody specificity allows for a calculated panel reactive antibodies (cPRA) value, providing an estimate of the effective donor pool. For broadly sensitized lung transplant candidates (cPRA ≥ 80%), our center adopted a pretransplant multimodal desensitization protocol in an effort to decrease the cPRA and expand the donor pool. This desensitization protocol included plasmapheresis, solumedrol, bortezomib and rituximab given in combination over 19 days followed by intravenous immunoglobulin. Eight of 18 candidates completed therapy with the primary reasons for early discontinuation being transplant (by avoiding unacceptable antigens) or thrombocytopenia. In a mixed-model analysis, there were no significant changes in PRA or cPRA changes over time with the protocol. A sub-analysis of the median fluorescence intensity (MFI) change indicated a small decline that was significant in antibodies with MFI 5000–10 000. Nine of 18 candidates subsequently had a transplant. Posttransplant survival in these nine recipients was comparable to other pretransplant-sensitized recipients who did not receive therapy. In summary, an aggressive multi-modal desensitization protocol does not significantly reduce pretransplant HLA antibodies in a broadly sensitized lung transplant candidate cohort. PMID:24666831

  6. Physical and chemical properties of orthodontic brackets after 12 and 24 months: in situ study

    Directory of Open Access Journals (Sweden)

    Bernardo de Azevedo Bahia MENDES

    2014-06-01

    Full Text Available Objective: The aim of this article was to assess how intraoral biodegradation influenced the surface characteristics and friction levels of metallic brackets used during 12 and 24 months of orthodontic treatment and also to compare the static friction generated in these brackets with four different methods of the ligation of orthodontic wires. Material and Methods: Seventy premolar brackets as received from the manufacturer and 224 brackets that were used in previous orthodontic treatments were evaluated in this experiment. The surface morphology and the composition of the deposits found in the brackets were evaluated with rugosimetry, scanning electron microscopy, and energy dispersive X-ray spectroscopy. Friction was analyzed by applying tensile tests simulating sliding mechanics with a 0.019x0.025" steel wire. The static friction levels produced by the following ligation methods were evaluated: loosely attached steel ligature around all four bracket wings, steel ligature attached to only two wings, conventional elastomeric ligation around all 4 bracket wings, and non-conventional Slide® elastomeric ligature. Results: The results demonstrated the presence of biodegradation effects such as corrosion pits, plastic deformation, cracks, and material deposits. The main chemical elements found on these deposits were Carbon and Oxygen. The maximum friction produced by each ligation method changed according to the time of intraoral use. The steel ligature loosely attached to all four bracket wings produced the lowest friction levels in the new brackets. The conventional elastic ligatures generated the highest friction levels. The metallic brackets underwent significant degradation during orthodontic treatment, showing an increase in surface roughness and the deposit of chemical elements on the surface. Conclusion: The levels of static friction decreased with use. The non-conventional elastic ligatures were the best alternative to reduce friction.

  7. Physical and chemical properties of orthodontic brackets after 12 and 24 months: in situ study

    Science.gov (United States)

    MENDES, Bernardo de Azevedo Bahia; FERREIRA, Ricardo Alberto Neto; PITHON, Matheus Melo; HORTA, Martinho Campolina Rebello; OLIVEIRA, Dauro Douglas

    2014-01-01

    Objective The aim of this article was to assess how intraoral biodegradation influenced the surface characteristics and friction levels of metallic brackets used during 12 and 24 months of orthodontic treatment and also to compare the static friction generated in these brackets with four different methods of the ligation of orthodontic wires. Material and Methods Seventy premolar brackets as received from the manufacturer and 224 brackets that were used in previous orthodontic treatments were evaluated in this experiment. The surface morphology and the composition of the deposits found in the brackets were evaluated with rugosimetry, scanning electron microscopy, and energy dispersive X-ray spectroscopy. Friction was analyzed by applying tensile tests simulating sliding mechanics with a 0.019x0.025" steel wire. The static friction levels produced by the following ligation methods were evaluated: loosely attached steel ligature around all four bracket wings, steel ligature attached to only two wings, conventional elastomeric ligation around all 4 bracket wings, and non-conventional Slide® elastomeric ligature. Results The results demonstrated the presence of biodegradation effects such as corrosion pits, plastic deformation, cracks, and material deposits. The main chemical elements found on these deposits were Carbon and Oxygen. The maximum friction produced by each ligation method changed according to the time of intraoral use. The steel ligature loosely attached to all four bracket wings produced the lowest friction levels in the new brackets. The conventional elastic ligatures generated the highest friction levels. The metallic brackets underwent significant degradation during orthodontic treatment, showing an increase in surface roughness and the deposit of chemical elements on the surface. Conclusion The levels of static friction decreased with use. The non-conventional elastic ligatures were the best alternative to reduce friction. PMID:25025560

  8. Physical and chemical properties of orthodontic brackets after 12 and 24 months: in situ study.

    Science.gov (United States)

    Mendes, Bernardo de Azevedo Bahia; Neto Ferreira, Ricardo Alberto; Pithon, Matheus Melo; Horta, Martinho Campolina Rebello; Oliveira, Dauro Douglas

    2014-06-01

    The aim of this article was to assess how intraoral biodegradation influenced the surface characteristics and friction levels of metallic brackets used during 12 and 24 months of orthodontic treatment and also to compare the static friction generated in these brackets with four different methods of the ligation of orthodontic wires. Seventy premolar brackets as received from the manufacturer and 224 brackets that were used in previous orthodontic treatments were evaluated in this experiment. The surface morphology and the composition of the deposits found in the brackets were evaluated with rugosimetry, scanning electron microscopy, and energy dispersive X-ray spectroscopy. Friction was analyzed by applying tensile tests simulating sliding mechanics with a 0.019x0.025" steel wire. The static friction levels produced by the following ligation methods were evaluated: loosely attached steel ligature around all four bracket wings, steel ligature attached to only two wings, conventional elastomeric ligation around all 4 bracket wings, and non-conventional Slide® elastomeric ligature. The results demonstrated the presence of biodegradation effects such as corrosion pits, plastic deformation, cracks, and material deposits. The main chemical elements found on these deposits were Carbon and Oxygen. The maximum friction produced by each ligation method changed according to the time of intraoral use. The steel ligature loosely attached to all four bracket wings produced the lowest friction levels in the new brackets. The conventional elastic ligatures generated the highest friction levels. The metallic brackets underwent significant degradation during orthodontic treatment, showing an increase in surface roughness and the deposit of chemical elements on the surface. The levels of static friction decreased with use. The non-conventional elastic ligatures were the best alternative to reduce friction.

  9. Correlative roentgenography and morphology of the longitudinal epiphyseal bracket

    International Nuclear Information System (INIS)

    Ogden, J.A.; Light, T.R.; Conlogue, G.J.; Yale Univ., New Haven, CT

    1981-01-01

    Detailed examination of a complete chondro-osseous specimen from a patient with duplication of the first ray of the foot revealed the involved metatarsal had a trapezoid-shaped, diaphyseal-metaphyseal osseous unit that was longitudinally bracketed along the lateral side by a functioning physis, epiphysis, and secondary (epiphyseal) ossification center. The physis extended as an arc from the medial proximal side toward and along the lateral side and then back to the medial side distally. The medial side of the diaphysis had a normal periosteum. The longitudinal epiphyseal ossification bracket was a composite of initially separate proximal and distal secondary ossification centers that had progressively extended toward each other and finally coalesced along the laterally placed epiphyseal cartilage. We have termed this deformity the 'longitudinal epiphyseal bracket' (LEB). The macroscopic and microscopic anatomy relevant to initial diagnosis and evaluation of sequential roentgenographic changes will be considered. (orig.)

  10. Shear bond strength of metallic and ceramic brackets using color change adhesives

    Directory of Open Access Journals (Sweden)

    Aisha de Souza Gomes Stumpf

    2013-04-01

    Full Text Available OBJECTIVE: To determine the shear bond strength of orthodontic brackets using color change adhesives that are supposed to aid in removing excess of bonding material and compare them to a traditional adhesive. METHODS: Ninety metallic and ninety ceramic brackets were bonded to bovine incisors using two color change adhesives and a regular one. A tensile stress was applied by a universal testing machine. The teeth were observed in a microscope after debonding in order to determine the Adhesive Remnant Index (ARI. RESULTS: The statistical analysis (ANOVA, Tukey, and Kruskall-Wallis tests demonstrated that the mean bond strength presented no difference when metallic and ceramic brackets were compared but the bond resistance values were significantly different for the three adhesives used. The most common ARI outcome was the entire adhesive remaining on the enamel. CONCLUSIONS: The bond strength was similar for metallic and ceramic brackets when the same adhesive system was used. ARI scores demonstrated that bonding with these adhesives is safe even when ceramic brackets were used. On the other hand, bond strength was too low for orthodontic purposes when Ortho Lite Cure was used.

  11. Evaluation of a new nano-filled restorative material for bonding orthodontic brackets.

    Science.gov (United States)

    Bishara, Samir E; Ajlouni, Raed; Soliman, Manal M; Oonsombat, Charuphan; Laffoon, John F; Warren, John

    2007-01-01

    To compare the shear bond strength of a nano-hybrid restorative material, Grandio (Voco, Cuxhaven, Germany), to that of a traditional adhesive material (Transbond XT; 3M Unitek, Monrovia, CA, USA) when bonding orthodontic brackets. Forty teeth were randomly divided into 2 groups: 20 teeth were bonded with the Transbond adhesive system and the other 20 teeth with the Grandio restorative system, following manufacturer's instructions. Student t test was used to compare the shear bond strength of the 2 systems. Significance was predetermined at P 5 .05. The t test comparisons (t = 0.55) of the shear bond strength between the 2 adhesives indicated the absence of a significant (P = .585) difference. The mean shear bond strength for Grandio was 4.1 +/- 2.6 MPa and that for Transbond XT was 4.6 +/- 3.2 MPa. During debonding, 3 of 20 brackets (15%) bonded with Grandio failed without registering any force on the Zwick recording. None of the brackets bonded with Transbond XT had a similar failure mode. The newly introduced nano-filled composite materials can potentially be used to bond orthodontic brackets to teeth if its consistency can be more flowable to readily adhere to the bracket base.

  12. Outpatient rapid 4-step desensitization for gynecologic oncology patients with mild to low-risk, moderate hypersensitivity reactions to carboplatin/cisplatin.

    Science.gov (United States)

    Li, Quan; Cohn, David; Waller, Allyson; Backes, Floor; Copeland, Larry; Fowler, Jeffrey; Salani, Ritu; O'Malley, David

    2014-10-01

    The primary objective of this study is to assess the efficacy and safety of an outpatient, 4-step, one-solution desensitization protocol in gynecologic oncology patients with history of mild to low-risk, moderate hypersensitivity reactions (HSRs) to platinums (carboplatin and cisplatin). This was a single institutional retrospective review. Gynecologic oncology patients with a documented history of mild or low-risk, moderate immediate HSRs to carboplatin/cisplatin and continued treatment with 4-step, one-solution desensitization protocols in the outpatient infusion center were included. Patients with delayed HSRs or immediate high-risk, moderate or severe HSRs were excluded. The primary end point was the rate of successful administrations of each course of platinums. From January 2011 to June 2013, eighteen eligible patients were evaluated for outpatient 4-step, one-solution desensitization. Thirteen patients had a history of HSRs to carboplatin and 5 with HSRs to cisplatin. All of 18 patients successfully completed 94 (98.9%) of 95 desensitization courses in the outpatient infusion center. Eight of 8 (100%) patients with initial mild HSRs completed 29/29 (100%) desensitization courses, and 9 of 10 (90%) of patients with initial moderate HSRs completed 65/66 (94%) desensitization courses. In total, 65/95 (68%) desensitizations resulted in no breakthrough reactions, and mild, moderate and severe breakthrough reactions were seen in 19%, 12% and 1% desensitizations, respectively. No patients were hospitalized during desensitization. The outpatient rapid, 4-step, one-solution desensitization protocol was effective and appeared safe among gynecologic oncology patients who experienced mild to low-risk, moderate HSRs to carboplatin/cisplatin. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Bihamiltonian Cohomology of KdV Brackets

    NARCIS (Netherlands)

    Carlet, G.; Posthuma, H.; Shadrin, S.

    2016-01-01

    Using spectral sequences techniques we compute the bihamiltonian cohomology groups of the pencil of Poisson brackets of dispersionless KdV hierarchy. In particular, this proves a conjecture of Liu and Zhang about the vanishing of such cohomology groups.

  14. Galvanic Corrosion of and Ion Release from Various Orthodontic Brackets and Wires in a Fluoride-containing Mouthwash

    Directory of Open Access Journals (Sweden)

    Soodeh Tahmasbi

    2015-09-01

    Full Text Available Background and aims. This study compared the galvanic corrosion of orthodontic wires and brackets from various man-ufacturers following exposure to a fluoride mouthwash. Materials and methods. This study was conducted on 24 lower central incisor 0.022” Roth brackets of four different commercially available brands (Dentaurum, American Orthodontics, ORJ, Shinye. These brackets along with stainless steel (SS or nickel-titanium (NiTi orthodontic wires (0.016", round were immersed in Oral-B mouthwash containing 0.05% sodium fluoride for 28 days. The electric potential (EP difference of each bracket-wire couple was measured with a Satu-rated Calomel Reference Electrode (Ag/AgCl saturated with KCl via a voltmeter. The ions released in the electrolyte weremeasured with an atomic absorption spectrometer. All the specimens were assessed under a stereomicroscope and speci-mens with corrosion were analyzed with scanning electron microscopy (SEM. Data were analyzed using ANOVA. Results. The copper ions released from specimens with NiTi wire were greater than those of samples containing SS wire. ORJ brackets released more Cu ions than other samples. The Ni ions released from Shinye brackets were significantly more than those of other specimens (P < 0.05. Corrosion rate of brackets coupled with NiTi wires was higher than that of brack-ets coupled with SS wires. Light and electron microscopic observations showed greater corrosion of ORJ brackets. Conclusion. In fluoride mouthwash, Shinye and ORJ brackets exhibited greater corrosion than Dentaurum and American Orthodontics brackets. Stainless steel brackets used with NiTi wires showed greater corrosion and thus caution is recom-mended when using them.

  15. Increasing access to kidney transplantation for sensitized recipient through three-way kidney paired donation with desensitization: The first Indian report

    Science.gov (United States)

    Kute, Vivek B; Patel, Himanshu V; Shah, Pankaj R; Modi, Pranjal R; Shah, Veena R; Rizvi, Sayyed J; Pal, Bipin C; Modi, Manisha P; Shah, Priya S; Varyani, Umesh T; Wakhare, Pavan S; Shinde, Saiprasad G; Ghodela, Viajay A; Patel, Minaxi H; Trivedi, Varsha B; Trivedi, Hargovind L

    2016-01-01

    The combination of kidney paired donation (KPD) with desensitization represents a promising method of increasing the rate of living donor kidney transplantation (LDKT) in immunologically challenging patients. Patients who are difficult to match and desensitize due to strong donor specific antibody are may be transplanted by a combination of desensitization and KPD protocol with more immunologically favorable donor. We present our experience of combination of desensitization protocol with three-way KPD which contributed to successful LDKT in highly sensitized end stage renal disease patient. All recipients were discharged with normal and stable allograft function at 24 mo follow up. We believe that this is first report from India where three-way KPD exchange was performed with the combination of KPD and desensitization. The combination of desensitization protocol with KPD improves access and outcomes of LDKT. PMID:27803919

  16. Counselor-Subject Sex Variables in Systematic Desensitization

    Science.gov (United States)

    Geer, Carol A.; Hurst, James C.

    1976-01-01

    A Sex of Subject x Sex of Counselor interaction in the desensitization of test anxiety among 44 college students suggested consideration of the sex variable. Results showed significant treatment effects by both male and female counselors and a significant interaction effect by the male counselor with female subjects. (Author)

  17. Evaluation of Antibacterial Effects of Silver-Coated Stainless Steel Orthodontic Brackets.

    Science.gov (United States)

    Arash, Valiollah; Keikhaee, Fatemeh; Rabiee, Sayed Mahmood; Rajabnia, Ramazan; Khafri, Soraya; Tavanafar, Saeid

    2016-01-01

    White spots and enamel demineralization around orthodontic brackets are among the most important complications resulting from orthodontic treatments. Since the antibacterial properties of metals and metallic particles have been well documented, the aim of this study was to assess the antibacterial effect of stainless steel orthodontic brackets coated with silver (Ag) particles. In this study, 40 standard metal brackets were divided into two groups of 20 cases and 20 controls. The brackets in the case group were coated with Ag particles using an electroplating method. Atomic force microscopy and scanning electron microscopy were used to assess the adequacy of the coating process. In addition, antibacterial tests, i.e., disk diffusion and direct contact tests were performed at three, six, 24, and 48 hours, and 15 and 30 days using a Streptococcus mutans strain. The results were analyzed using Student's t-test and repeated measures ANOVA. Analyses via SEM and AFM confirmed that excellent coatings were obtained by using an electroplating method. The groups exhibited similar behavior when subjected to the disk diffusion test in the agar medium. However, the bacterial counts of the Ag-coated brackets were, in general, significantly lower (PBrackets coated with Ag, via an electroplating method, exhibited antibacterial properties when placed in direct contact with Streptococcus mutans. This antibacterial effect persisted for 30 days after contact with the bacteria.

  18. In vitro dentin permeability after application of Gluma® desensitizer as aqueous solution or aqueous fumed silica dispersion

    Directory of Open Access Journals (Sweden)

    Hiroshi Ishihata

    2011-04-01

    Full Text Available OBJECTIVES: To assess and to compare the effects of Gluma® Desensitizer (GDL with an experimental glutaraldehyde and HEMA containing fumed silica dispersion (GDG on dentin permeability using a chemiluminous tracer penetration test. MATERIAL AND METHODS: Twenty disc-shaped dentin specimens were dissected from extracted human third molars. The dentin specimens were mounted in a split chamber device for determination of permeability under liquid pressure using a photochemical method. Ten specimens were randomly selected and allocated to the evaluation groups Gluma® Desensitizer as aqueous solution and glutaraldehyde/HEMA as fumed silica dispersion, respectively. Dentin disc permeability was determined at two pressure levels after removal of smear with EDTA, after albumin soaking, and after application of the desensitizing agents. Two desensitizer-treated and rinsed specimens of each group were examined by scanning electron microscopy (SEM for surface remnants. RESULTS: Comparatively large standard deviations of the mean EDTA reference and albumin soaked samples permeability values refected the differences of the dentin substrates. The mean chemiluminescence values of specimen treated with GDL and GDG, respectively, were signifcantly reduced after topical application of the desensitizing agents on albumin-soaked dentin. The effects of GDL and GDG on permeability were not signifcantly different. Treated specimens showed no surface remnants after rinsing. CONCLUSIONS: The experimental desensitizer gel formulation reduced dentin permeability as effectively as the original Gluma® Desensitizer solution.

  19. Concurrent engineering solution for the design of ship and offshore bracket parts and fabrication process

    Directory of Open Access Journals (Sweden)

    Tae-Won Kim

    2013-09-01

    Full Text Available Brackets in ships and offshore structures are added structures that can endure stress concentrations. In this study, a concurrent engineering solution was proposed, and a high strength low carbon cast steel alloy applicable to offshore structures was designed and developed. The yield strength and ultimate tensile strength of the designed steel were 480 and 600 MPa, respectively. The carbon equivalent of the steel was 0.446 with a weld crack susceptibility index of 0.219. The optimal structural design of the brackets for offshore structures was evaluated using ANSYS commercial software. The possibility of replacing an assembly of conventional built-up brackets with a single casting bulb bracket was verified. The casting process was simulated using MAGMAsoft commercial software, and a casting fabrication process was designed. For the proposed bulb bracket, it was possible to reduce the size and weight by approximately 30% and 50%, respectively, compared to the conventional type of bracket.

  20. Effect of time and pH on physical-chemical properties of orthodontic brackets and wires.

    Science.gov (United States)

    Dos Santos, Aretha Aliny Ramos; Pithon, Matheus Melo; Carlo, Fabíola Galbiatti Carvalho; Carlo, Hugo Lemes; de Lima, Bruno Alessandro Silva Guedes; Dos Passos, Tibério Andrade; Lacerda-Santos, Rogério

    2015-03-01

    To test the hypothesis that treatment time, debris/biofilm, and oral pH have an influence on the physical-chemical properties of orthodontic brackets and arch wires. One hundred twenty metal brackets were evaluated. They were divided into four groups (n  =  30) according to treatment time: group C (control) and groups T12, T24, and T36 (brackets recovered after 12, 24, and 36 months of treatment, respectively). Rectangular stainless-steel arch wires that remained in the oral cavity for 12 to 24 months were also analyzed. Dimensional stability, surface morphology, composition of brackets, resistance to sliding of the bracket-wire set, surface roughness of wires, and oral pH were analyzed. One-way analysis of variance, followed by a Tukey multiple comparisons test, was used for statistical analysis (P bracket slots were shown to have more influence on the degradation process and frictional force of these devices than did oral pH.

  1. Ulcerative colitis patients with an inflammatory response upon mesalazine cannot be desensitized: a randomized study.

    Science.gov (United States)

    Buurman, Dorien J; De Monchy, Jan G R; Schellekens, Reinout C A; van der Waaij, Laurens A; Kleibeuker, Jan H; Dijkstra, Gerard

    2015-04-01

    Mesalazine is a key drug in the treatment of ulcerative colitis (UC). Intolerance to mesalazine has been described, including fever and gastrointestinal symptoms. Several case reports reported successful desensitization of patients with mesalazine intolerance. The aim was to assess the number of UC patients who are persistently intolerant to mesalazine after single-blinded rechallenge and to test the effectiveness of a rapid desensitization protocol in UC patients demonstrated mesalazine intolerance. This is a prospective, single-blind randomized study in UC patients who discontinued mesalazine because of intolerance. Patients with severe reactions were excluded. Eligible patients underwent a skin patch test with mesalazine followed by a single-blinded randomized crossover rechallenge with 500 mg mesalazine or placebo. Patients with symptoms upon rechallenge were admitted to the hospital for 3 days oral desensitization. Nine of the 37 identified UC patients who discontinued mesalazine because of intolerance were included. All nine patients had negative patch tests, seven patients had symptoms (fever, nausea, vomiting and diarrhea) within 2 h upon rechallenge. Four of these seven patients participated in the desensitization protocol and in none a successful desensitization could be performed. All four had an inflammatory intolerance reaction with rise in C-reactive protein. There were no elevations in serum tryptase or urinary-methylhistamine levels observed and no signs of immediate type allergic reactions, like urticaria, bronchial obstruction or anaphylaxis. We recommend not to rechallenge UC patients with an inflammatory response upon mesalazine and these patients will not benefit from a rapid desensitization protocol.

  2. Effects of near infrared laser radiation associated with photoabsorbing cream in preventing white spot lesions around orthodontic brackets: an in vitro study.

    Science.gov (United States)

    Lacerda, Ângela Sueli Soares Braga; Hanashiro, Fernando Seishim; de Sant'Anna, Giselle Rodrigues; Steagall Júnior, Washington; Barbosa, Patrícia Silva; de Souza-Zaroni, Wanessa Christine

    2014-12-01

    The present study aims to investigate the effect of a low-power infrared laser on the inhibition of bovine enamel demineralization around orthodontic brackets. Near infrared lasers have been suggested as alternative approaches because they may produce an increase in resistance to dental caries. Forty-eight blocks of enamel obtained from bovine incisor teeth were divided into six groups: Group 1 (control), without treatment; Group 2 (C), photoabsorbing cream; Group 3 (CF), photoabsorbing cream with fluoride; Group 4 (L), irradiation with low-level infrared laser (λ=830 nm) at an energy density of 4.47 J/cm2; Group 5 (L+C), photoabsorbing cream followed by low-level infrared laser irradiation; and Group 6 (L+CF), photoabsorbing cream with fluoride followed by low-level infrared laser irradiation. After these procedures, the enamel blocks received an assortment of orthodontic brackets and were then submitted to pH cycling to simulate a highly cariogenic challenge. The enamel surface demineralization around the orthodontic brackets, according to the different treatments, was quantified by fluorescence loss analysis by quantitative light-induced fluorescence (QLF). The fluorescence loss, expressed as ΔF (percentage of loss fluorescence), was statistically examined by analysis of variance and the Tukey test. The control group (-10.48±2.85) was statistically similar to Group C (-14.52±7.80), which presented the lowest values of ΔF when compared with Groups FC (-3.67±3.21), L (-2.79±1.68), CL (-1.05±0:50), and CFL (-0.60±0:43). However, Groups FC, L, CL, and CFL showed no statistically significant differences among them. It can be concluded that both the low-level infrared laser and photoabsorbing cream with fluoride were effective in inhibiting the development of caries in enamel around orthodontic brackets, even in situations of high cariogenic challenge.

  3. Kidney paired exchange and desensitization: Strategies to transplant the difficult to match kidney patients with living donors.

    Science.gov (United States)

    Pham, Thomas A; Lee, Jacqueline I; Melcher, Marc L

    2017-01-01

    With organs in short supply, only a limited number of kidney transplants can be performed a year. Live donor donation accounts for 1/3rd of all kidney transplants performed in the United States. Unfortunately, not every donor recipient pair is feasible because of Human leukocyte antigen (HLA) sensitization and ABO incompatibility. To overcome these barriers to transplant, strategies such as kidney paired donation (KPD) and desensitization have been developed. KPD is the exchange of donors between at least two incompatible donor-recipient pairs such that they are now compatible. Desensitization is the removal of circulating donor specific antibodies to prevent graft rejection. Regardless of the treatment strategy, highly sensitized patients whose calculated panel reactive antibody (cPRA) is ≥95% remain difficult to transplant with match rates as low as 15% in KPD pools. Desensitization has proved to be difficult in those with high antibody titers. A novel approach is the combination of both KPD and desensitization to facilitate compatible and successful transplantation. A highly sensitized patient can be paired with a better immunological match in the KPD pool and subsequently desensitized to a lesser degree. This article reviews the current progress in KPD and desensitization and their use as a combined therapy. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. The effect of ZnO nanoparticle coating on the frictional resistance between orthodontic wires and ceramic brackets

    Science.gov (United States)

    Behroozian, Ahmad; Kachoei, Mojgan; Khatamian, Masumeh; Divband, Baharak

    2016-01-01

    Background. Any decrease in friction between orthodontic wire and bracket can accelerate tooth movement in the sliding technique and result in better control of anchorage. This study was carried out to evaluate frictional forces by coating orthodontic wires and porcelain brackets with zinc oxide nanoparticles (ZnO). Methods. In this in vitro study, we evaluated a combination of 120 samples of 0.019×0.025 stainless steel (SS) orthodonticwires and 22 mil system edgewise porcelain brackets with and without spherical zinc oxide nanoparticles. Spherical ZnOnanoparticles were deposited on wires and brackets by immersing them in ethanol solution and SEM (scanning electronmicroscope) evaluation confirmed the presence of the ZnO coating. The frictional forces were calculated between the wiresand brackets in four groups: group ZZ (coated wire and bracket), group OO (uncoated wire and bracket), group ZO (coatedwire and uncoated bracket) and group OZ (uncoated wire and coated bracket). Kolmogorov-Smirnov, Mann-Whitney andKruskal-Wallis tests were used for data analysis. Results. The frictional force in ZZ (3.07±0.4 N) was the highest (P <0.05), and OZ (2.18±0.5 N) had the lowest amount of friction (P <0.05) among the groups. There was no significant difference in frictional forces between the ZO and OO groups (2.65±0.2 and 2.70±0.2 N, respectively). Conclusion. Coating of porcelain bracket surfaces with ZnO nanoparticles can decrease friction in the sliding technique,and wire coating combined with bracket coating is not recommended due to its effect on friction. PMID:27429727

  5. Desensitization Protocol in Recipients of Deceased Kidney Donor With Donor-Specific Antibody-Low Titers.

    Science.gov (United States)

    Kanter Berga, J; Sancho Calabuig, A; Gavela Martinez, E; Puig Alcaraz, N; Avila Bernabeu, A; Crespo Albiach, J; Molina Vila, P; Beltrán Catalan, S; Pallardó Mateu, L

    2016-11-01

    Kidney transplantation is the better option for end-stage renal disease (ESRD), but for patients with human leukocyte antigen (HLA) sensitization, the wait times are significantly longer than for patients without antibodies. Many desensitization protocols have been described involving strong immunosuppression, the use of apheresis, and B-cell-modulating therapies. We have designed a desensitization protocol from day 0 for deceased donor kidney transplantation. Our aim was to present our initial experience with five kidney transplant patients. All patients had a negative complement-dependent cytotoxicity cross-match. The desensitization protocol included five to seven doses of thymoglobulin (1.25 mg/kg) and three sessions of plasmapheresis (PP) within the first week after transplantation, with intravenous immunoglobulin (500 mg/kg) after each PP session and one dose of rituximab on day 8. The presence of donor-specific antibodies (DSA) was analyzed by use of Luminex technology; levels between 1000 and 3000 mean fluorescence intensity were considered for desensitization. The median age was 44 years and median renal replacement therapy time was 9 years. All recipients presented 1 to 3 DSA specificities. There were no severe side effects related to PP, infusion of intravenous immunoglobulin, or rituximab. The median follow-up period was 19.3 months. Median serum creatinine level at last follow-up was 1.7 mg/dL. A kidney biopsy was performed in all patients. Graft and patient survival was 100%. Until now, few data are available concerning whether HLA-incompatible kidney transplantation after desensitization would benefit patients with ERSD. The desensitization strategy using the combination of PP, low doses of intravenous immunoglobulin, and rituximab at our center resulted in a satisfactory clinical outcome. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. The Effect of Self and In Vivo Desensitization on Counselor Trainee Anxiety and Performance.

    Science.gov (United States)

    Miller, Thomas V.

    The rationale, planning and implementing of this research is discussed in terms of its three hypotheses: (1) that both self desensitization and in vivo desensitization would result in lower Fear Index and Anxiety Differential scores of counselor trainees just prior to communicating with a role playing client in a counseling room where they are…

  7. A comparative study of metal artifacts from common metal orthodontic brackets in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Kajan, Zahra Dalili; Alizadeh, Ahmad; Hemmaty, Yasmin Babael; Roushan, Zahra Atrkar; Khademi, Jalil

    2015-01-01

    This study was performed to compare the metal artifacts from common metal orthodontic brackets in magnetic resonance imaging. A dry mandible with 12 intact premolars was prepared, and was scanned ten times with various types of brackets: American, 3M, Dentaurum, and Masel orthodontic brackets were used, together with either stainless steel (SS) or nickel titanium (NiTi) wires. Subsequently, three different sequences of coronal and axial images were obtained: spin-echo T1-weighted images, fast spin-echo T2-weighted images, and fluid-attenuated inversion recovery images. In each sequence, the two sequential axial and coronal images with the largest signal-void area were selected. The largest diameters of the signal voids in the direction of the X-, Y-, and Z-axes were then measured twice. Finally, the mean linear values associated with different orthodontic brackets were analyzed using one-way analysis of variation, and the results were compared using the independent t-test to assess whether the use of SS or NiTi wires had a significant effect on the images. Statistically significant differences were only observed along the Z-axis among the four different brands of orthodontic brackets with SS wires. A statistically significant difference was observed along all axes among the brackets with NiTi wires. A statistically significant difference was found only along the Z-axis between nickel-free and nickel-containing brackets. With respect to all axes, the 3M bracket was associated with smaller signal-void areas. Overall, the 3M and Dentaurum brackets with NiTi wires induced smaller artifacts along all axes than those with SS wires

  8. A comparative study of metal artifacts from common metal orthodontic brackets in magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kajan, Zahra Dalili; Alizadeh, Ahmad; Hemmaty, Yasmin Babael; Roushan, Zahra Atrkar; Khademi, Jalil [Guilan University of Medical Sciences, Rasht (Iran, Islamic Republic of)

    2015-09-15

    This study was performed to compare the metal artifacts from common metal orthodontic brackets in magnetic resonance imaging. A dry mandible with 12 intact premolars was prepared, and was scanned ten times with various types of brackets: American, 3M, Dentaurum, and Masel orthodontic brackets were used, together with either stainless steel (SS) or nickel titanium (NiTi) wires. Subsequently, three different sequences of coronal and axial images were obtained: spin-echo T1-weighted images, fast spin-echo T2-weighted images, and fluid-attenuated inversion recovery images. In each sequence, the two sequential axial and coronal images with the largest signal-void area were selected. The largest diameters of the signal voids in the direction of the X-, Y-, and Z-axes were then measured twice. Finally, the mean linear values associated with different orthodontic brackets were analyzed using one-way analysis of variation, and the results were compared using the independent t-test to assess whether the use of SS or NiTi wires had a significant effect on the images. Statistically significant differences were only observed along the Z-axis among the four different brands of orthodontic brackets with SS wires. A statistically significant difference was observed along all axes among the brackets with NiTi wires. A statistically significant difference was found only along the Z-axis between nickel-free and nickel-containing brackets. With respect to all axes, the 3M bracket was associated with smaller signal-void areas. Overall, the 3M and Dentaurum brackets with NiTi wires induced smaller artifacts along all axes than those with SS wires.

  9. A comparative study of metal artifacts from common metal orthodontic brackets in magnetic resonance imaging.

    Science.gov (United States)

    Dalili Kajan, Zahra; Khademi, Jalil; Alizadeh, Ahmad; Babaei Hemmaty, Yasamin; Atrkar Roushan, Zahra

    2015-09-01

    This study was performed to compare the metal artifacts from common metal orthodontic brackets in magnetic resonance imaging. A dry mandible with 12 intact premolars was prepared, and was scanned ten times with various types of brackets: American, 3M, Dentaurum, and Masel orthodontic brackets were used, together with either stainless steel (SS) or nickel titanium (NiTi) wires. Subsequently, three different sequences of coronal and axial images were obtained: spin-echo T1 -weighted images, fast spin-echo T2 -weighted images, and fluid-attenuated inversion recovery images. In each sequence, the two sequential axial and coronal images with the largest signal-void area were selected. The largest diameters of the signal voids in the direction of the X-, Y-, and Z-axes were then measured twice. Finally, the mean linear values associated with different orthodontic brackets were analyzed using one-way analysis of variation, and the results were compared using the independent t-test to assess whether the use of SS or NiTi wires had a significant effect on the images. Statistically significant differences were only observed along the Z-axis among the four different brands of orthodontic brackets with SS wires. A statistically significant difference was observed along all axes among the brackets with NiTi wires. A statistically significant difference was found only along the Z-axis between nickel-free and nickel-containing brackets. With respect to all axes, the 3M bracket was associated with smaller signal-void areas. Overall, the 3M and Dentaurum brackets with NiTi wires induced smaller artifacts along all axes than those with SS wires.

  10. Monoidal categories and the Gerstenhaber bracket in Hochschild cohomology

    CERN Document Server

    Hermann, Reiner

    2016-01-01

    In this monograph, the author extends S. Schwede's exact sequence interpretation of the Gerstenhaber bracket in Hochschild cohomology to certain exact and monoidal categories. Therefore the author establishes an explicit description of an isomorphism by A. Neeman and V. Retakh, which links \\mathrm{Ext}-groups with fundamental groups of categories of extensions and relies on expressing the fundamental group of a (small) category by means of the associated Quillen groupoid. As a main result, the author shows that his construction behaves well with respect to structure preserving functors between exact monoidal categories. The author uses his main result to conclude, that the graded Lie bracket in Hochschild cohomology is an invariant under Morita equivalence. For quasi-triangular bialgebras, he further determines a significant part of the Lie bracket's kernel, and thereby proves a conjecture by L. Menichi. Along the way, the author introduces n-extension closed and entirely extension closed subcategories of abe...

  11. Clinical effects of pre-adjusted edgewise orthodontic brackets: a systematic review and meta-analysis.

    Science.gov (United States)

    Papageorgiou, Spyridon N; Konstantinidis, Ioannis; Papadopoulou, Konstantina; Jäger, Andreas; Bourauel, Christoph

    2014-06-01

    Fixed-appliance treatment is a major part of orthodontic treatment, but clinical evidence remains scarce. Objective of this systematic review was to investigate how the therapeutic effects and side-effects of brackets used during the fixed-appliance orthodontic treatment are affected by their characteristics. SEARCH METHODS AND SELECTION CRITERIA: We searched MEDLINE and 18 other databases through April 2012 without restrictions for randomized controlled trials and quasi-randomized controlled trials investigating any bracket characteristic. After duplicate selection and extraction procedures, risk of bias was assessed also in duplicate according to Cochrane guidelines and quality of evidence according to the Grades of Recommendation. Assessment, Development and Evaluation approach. Random-effects meta-analyses, subgroup analyses, and sensitivity analyses were performed with the corresponding 95 per cent confidence intervals (CI) and 95 per cent prediction intervals (PI). We included 25 trials on 1321 patients, with most comparing self-ligated (SL) and conventional brackets. Based on the meta-analyses, the duration of orthodontic treatment was on average 2.01 months longer among patients with SL brackets (95 per cent CI: 0.45 to 3.57). The 95 per cent PIs for a future trial indicated that the difference could be considerable (-1.46 to 5.47 months). Treatment characteristics, outcomes, and side-effects were clinically similar between SL and conventional brackets. For most bracket characteristics, evidence is insufficient. Some meta-analyses included trials with high risk of bias, but sensitivity analyses indicated robustness. Based on existing evidence, no clinical recommendation can be made regarding the bracket material or different ligation modules. For SL brackets, no conclusive benefits could be proven, while their use was associated with longer treatment durations.

  12. Assessment of dimensional accuracy of preadjusted metal injection molding orthodontic brackets.

    Science.gov (United States)

    Alavi, Shiva; Tajmirriahi, Farnaz

    2016-09-01

    the aim of this study is to evaluate the dimensional accuracy of McLaughlin, Bennett, and Trevisi (MBT) brackets manufactured by two different companies (American Orthodontics and Ortho Organizers) and determine variations in incorporation of values in relation to tip and torque in these products. In the present analytical/descriptive study, 64 maxillary right central brackets manufactured by two companies (American Orthodontics and Ortho Organizers) were selected randomly and evaluated for the accuracy of the values in relation to torque and angulation presented by the manufacturers. They were placed in a video measuring machine using special revolvers under them and were positioned in a manner so that the light beams would be directed on the floor of the slot without the slot walls being seen. Then, the software program of the same machine was used to determine the values of each bracket type. The means of measurements were determined for each sample and were analyzed with independent t -test and one-sample t -test. Based on the confidence interval, it can be concluded that at 95% probability, the means of tip angles of maxillary right central brackets of these two brands were 4.1-4.3° and the torque angles were 16.39-16.72°. The tips in these samples were at a range of 3.33-4.98°, and the torque was at a range of 15.22-18.48°. In the present study, there were no significant differences in the angulation incorporated into the brackets from the two companies; however, they were significantly different from the tiP values for the MBT prescription. In relation to torque, there was a significant difference between the American Orthodontic brackets exhibited significant differences with the reported 17°, too.

  13. Assessment of dimensional accuracy of preadjusted metal injection molding orthodontic brackets

    Directory of Open Access Journals (Sweden)

    Shiva Alavi

    2016-01-01

    Full Text Available Background: the aim of this study is to evaluate the dimensional accuracy of McLaughlin, Bennett, and Trevisi (MBT brackets manufactured by two different companies (American Orthodontics and Ortho Organizers and determine variations in incorporation of values in relation to tip and torque in these products. Materials and Methods: In the present analytical/descriptive study, 64 maxillary right central brackets manufactured by two companies (American Orthodontics and Ortho Organizers were selected randomly and evaluated for the accuracy of the values in relation to torque and angulation presented by the manufacturers. They were placed in a video measuring machine using special revolvers under them and were positioned in a manner so that the light beams would be directed on the floor of the slot without the slot walls being seen. Then, the software program of the same machine was used to determine the values of each bracket type. The means of measurements were determined for each sample and were analyzed with independent t-test and one-sample t-test. Results: Based on the confidence interval, it can be concluded that at 95% probability, the means of tip angles of maxillary right central brackets of these two brands were 4.1-4.3° and the torque angles were 16.39-16.72°. The tips in these samples were at a range of 3.33-4.98°, and the torque was at a range of 15.22-18.48°. Conclusion: In the present study, there were no significant differences in the angulation incorporated into the brackets from the two companies; however, they were significantly different from the tiP values for the MBT prescription. In relation to torque, there was a significant difference between the American Orthodontic brackets exhibited significant differences with the reported 17°, too.

  14. Psychodynamic Emotional Regulation in View of Wolpe's Desensitization Model.

    Science.gov (United States)

    Rabinovich, Merav

    2016-01-01

    The current research belongs to the stream of theoretical integration and establishes a theoretical platform for integrative psychotherapy in anxiety disorders. Qualitative metasynthesis procedures were applied to 40 peer-reviewed psychoanalytic articles involving emotional regulation. The concept of psychodynamic emotional regulation was found to be connected with the categories of desensitization, gradual exposure, containment, and transference. This article presents a model according to which psychoanalytic psychotherapy allows anxiety to be tolerated while following the core principles of systematic desensitization. It is shown that despite the antiresearch image of psychoanalytic psychotherapy, its foundations obey evidence-based principles. The findings imply that anxiety tolerance might be a key goal in which the cumulative wisdom of the different therapies can be used to optimize psychotherapy outcomes.

  15. 4-step 4-h carboplatin desensitization protocol for patients with gynecological malignancies showing platinum hypersensitivity: a retrospective study.

    Science.gov (United States)

    Takase, Naoto; Matsumoto, Koji; Onoe, Takuma; Kitao, Akihito; Tanioka, Maki; Kikukawa, Yoshitaka; Yamaguchi, Satoshi; Fujiwara, Kiyoshi; Negoro, Shunichi

    2015-06-01

    Platinum agents are essential for treating gynecological malignancies, particularly ovarian cancer. However, multiple carboplatin doses may cause hypersensitivity reactions (HSRs). Carboplatin desensitization prevents life-threatening HSRs and promotes the successful completion of planned chemotherapy. Since January 2010, carboplatin desensitization was performed at our institution. Solutions with 1/1000, 1/100, and 1/10 dilutions of carboplatin and an undiluted solution were prepared in 250 mL of 5% glucose. Each solution was administered as a 1-h intravenous infusion (4-step 4-h protocol). This retrospective analysis was approved by the institutional review board. From January 2010 to December 2013, 20 patients with gynecological malignancies (median age 62 years, range 43-74 years) received desensitization treatment. The International Federation of Gynecology and Obstetrics stages at presentation were I, II, III, and IV in 1, 1, 15, 13 patients, respectively. During first-line and second-line treatments, 3 and 17 patients, respectively, experienced carboplatin-induced HSRs. The median carboplatin cycle number was 11 (range 2-16). In the first desensitization cycle, 17 (85%) patients completed treatment without adverse events, 2 experienced Grade 1 HSRs but completed treatment, and 1 experienced Grade 3 HSR and discontinued treatment. The first desensitization cycle completion rate was 95%. Of 83 desensitization cycles administered, 79 (95.2%) were completed. No treatment-related deaths occurred. Most patients completed the planned chemotherapy. Our protocol could be conducted safely with shorter duration and simpler procedures than previous protocols. Carboplatin desensitization seems beneficial for patients with a history of carboplatin-induced HSRs; however, the risk of HSR recurrence still remains. Desensitization should therefore be performed only by well-trained staff.

  16. Orthodontic Metallic Lingual Brackets: The Dark Side of the Moon of Bond Failures?

    Directory of Open Access Journals (Sweden)

    Maria Francesca Sfondrini

    2017-07-01

    Full Text Available Lingual orthodontics, among both young and adult patients, increased in popularity during last years. The purposes of the present investigation were to evaluate the shear bond strength (SBS values and Adhesive Remnant Index (ARI scores of different lingual brackets compared with a vestibular control bracket. One hundred bovine teeth were extracted and embedded in resin blocks. Four different lingual brackets (Idea, Leone; STB, Ormco; TTR, RMO; 2D, Forestadent and a vestibular control bracket (Victory, 3M were bonded to the bovine enamel surfaces and subsequently shear tested to failure utilizing a Universal Testing Machine. SBS values were measured. A microscopic evaluation was performed to obtain ARI scores. Statistical analysis was performed at a statistically significant level of p < 0.05 to determine significant differences in SBS values and ARI Scores. No statistically significant variations in SBS were reported among the different groups. Conversely, significant differences were shown in ARI scores among the various groups. Clinical relevance of the present study is that orthodontists can expect similar resistance to debonding forces from lingual appliances as with vestibular brackets.

  17. Clinical acceptability of two self-etch adhesive resins for the bonding of orthodontic brackets to enamel.

    Science.gov (United States)

    Schnebel, Bradley; Mateer, Scott; Maganzini, Anthony Louis; Freeman, Katherine

    2012-12-01

    To determine whether two self-adhesive resin cements, Clearfil SA and RelyX, can be used to successfully bond orthodontic brackets to enamel. Seventy extracted premolars were custom mounted, cleaned and randomly divided into three groups. In group 1 (control), orthodontic brackets were bonded to 25 premolars using the Transbond Plus and Transbond XT two step adhesive systerm adhesive. In group 2, brackets were bonded to 25 premolars using Clearfil SA. In group 3, brackets were bonded to 20 premolars using RelyX. The brackets were debonded using a universal testing machine and shear bond strengths recorded. After debonding, each tooth was examined under 20× magnification to evaluate the residual adhesive remaining. An ANOVA with Duncan's Multiple Range Test was used to determine whether there were significant differences in shear bond strength between the groups. A Kruskal-Wallis Test and a Bonferroni multiple comparison procedure were used to compare the bond failure modes (adhesive remnant index scores) between the groups. The mean shear bond strengths for the brackets bonded using Clearfil SA and RelyX were 5·930±1·840 and 3·334±1·953 MPa, respectively. Both were significantly lower than that for the brackets bonded using Transbond (7·875±3·611 MPa). Both self-etch adhesive resin cement groups showed a greater incidence of bracket failure at the enamel/adhesive interface while the Transbond group showed a higher incidence at the bracket/adhesive interface. The shear bond strengths of the self-etch adhesive resin cements may be inadequate to successfully bond orthodontic brackets to enamel.

  18. Effects of silane application on the shear bond strength of ceramic orthodontic brackets to enamel surface

    Directory of Open Access Journals (Sweden)

    Pinandi Sri Pudyani

    2016-12-01

    Full Text Available Background: Fixed orthodontic appliances with ceramic brackets are used frequently to fulfill the aesthetic demand of patient through orthodontic treatment. Ceramic brackets have some weaknesses such as bond strength and enamel surface damage. In high bond strength the risk of damage in enamel surfaces increases after debonding. Purpose: This study aimed to determine the effect of silane on base of bracket and adhesive to shear bond strength and enamel structure of ceramic bracket. Method: Sixteen extracted upper premolars were randomly divided into four groups based on silane or no silane on the bracket base and on the adhesive surface. Design of the base on ceramic bracket in this research was microcrystalline to manage the influence of mechanical interlocking. Samples were tested in shear mode on a universal testing machine after attachment. Following it, adhesive remnant index (ARI scores were used to assess bond failure site. Statistical analysis was performed using a two-way Anova and the Mann-Whitney test. A scanning electron microscope (SEM with a magnification of 2000x was used to observe enamel structure after debonding. Result: Shear bond strength was increased between group without silane and group with silane on the base of bracket (p<0,05. There was no significance different between group without silane and group with silane on adhesive (p<0,05. Conclusion: Application of silane on base of bracket increases shear bond strength, however, application of silane on adhesive site does not increase shear bond strength of ceramic bracket. Most bonding failure occurred at the enamel adhesive interface and damage occurred on enamel structure in group contains silane of ceramic bracket.

  19. Comparison of Three Methods of Reducing Test Anxiety: Systematic Desensitization, Implosive Therapy, and Study Counseling

    Science.gov (United States)

    Cornish, Richard D.; Dilley, Josiah S.

    1973-01-01

    Systematic desensitization, implosive therapy, and study counseling have all been effective in reducing test anxiety. In addition, systematic desensitization has been compared to study counseling for effectiveness. This study compares all three methods and suggests that systematic desentization is more effective than the others, and that implosive…

  20. Comparison of Relaxation as Self-control and Systematic Desensitization in the Treatment of Test Anxiety

    Science.gov (United States)

    Snyder, Arden L.; Deffenbacher, Jerry L.

    1977-01-01

    Relaxation as self-control and desensitization were compared to a wait-list control in reduction of rest and other anxieties. Active treatments differed significantly from the control treatment. Subjects in both treatments reported less debilitating test anxiety, whereas desensitization subjects showed greater facilitating test anxiety. (Author)

  1. Elemental, microstructural, and mechanical characterization of high gold orthodontic brackets after intraoral aging.

    Science.gov (United States)

    Hersche, Sepp; Sifakakis, Iosif; Zinelis, Spiros; Eliades, Theodore

    2017-02-01

    The purpose of the present study was to investigate the elemental composition, the microstructure, and the selected mechanical properties of high gold orthodontic brackets after intraoral aging. Thirty Incognito™ (3M Unitek, Bad Essen, Germany) lingual brackets were studied, 15 brackets as received (control group) and 15 brackets retrieved from different patients after orthodontic treatment. The surface of the wing area was examined by scanning electron microscopy (SEM). Backscattered electron imaging (BEI) was performed, and the elemental composition was determined by X-ray EDS analysis (EDX). After appropriate metallographic preparation, the mechanical properties tested were Martens hardness (HM), indentation modulus (EIT), elastic index (ηIT), and Vickers hardness (HV). These properties were determined employing instrumented indentation testing (IIT) with a Vickers indenter. The results were statistically analyzed by unpaired t-test (α=0.05). There were no statistically significant differences evidenced in surface morphology and elemental content between the control and the experimental group. These two groups of brackets showed no statistically significant difference in surface morphology. Moreover, the mean values of HM, EIT, ηIT, and HV did not reach statistical significance between the groups (p>0.05). Under the limitations of this study, it may be concluded that the surface elemental content and microstructure as well as the evaluated mechanical properties of the Incognito™ lingual brackets remain unaffected by intraoral aging.

  2. REM Desensitization as a New Therapeutic Method for Post- Traumatic Stress Disorder: A Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    Khodabakhsh Ahmadi

    2016-05-01

    Full Text Available Aim: to evaluate potential efficacy of a new therapeutic approach in posttraumatic stress disorder in comparison with eye movement desensitization and reprocessing (EMDR, a standard treatment approach and controls. Methods: the study was designed using a randomized controlled trial methodology. Participants were recruited from military servicemen aged between 25 to 50 years who were admitting hospitals of Bushehr, Iran, with the final diagnosis of PTSD. Finally 33 male patients were devided into three subgroups: G1: EMDR; G2: REM Desensitization; and group 3: controls who received no therapy. Mississippi Scale for Posttraumatic Stress Disorder, Pittsburgh Sleep Quality Index (PSQI and a 37 item death anxiety questionnaire were used for measures. Results: multiple comparisons showed that intrusive thoughts were significantly more likely to improve with REM Desensitization versus EMDR (P=0.03, while depression was more responsive to EMDR (p=0.03. Among the Pittsburgh scale for the quality of sleep items, sleep quality (p=0.02, sleep duration (p=0.001, and total sleep quality score (p=0.002 were significantly more likely to improve in the REM Desensitization group. Change in the absolute death anxiety scores was not different between subgroups excepting EMDR versus control group (p=0.05. Conclusion: REM, desensitization, the new therapeutic approach to PTSD is a highly effective strategy, even more than EMDR, the standard treatment, in most of the evaluated subjects, with special emphasis on sleep symptoms, and also in the management of intrusive thoughts. Depression is the only factor in which, REM Desensitization was significantly less likely to represent a superior therapeutic effect than EMDR. Key words: post traumatic stress disorder (PTSD, eye movement desensitization and reprocessing, new treatment.

  3. A pilot study of omalizumab to facilitate rapid oral desensitization in high-risk peanut-allergic patients.

    Science.gov (United States)

    Schneider, Lynda C; Rachid, Rima; LeBovidge, Jennifer; Blood, Emily; Mittal, Mudita; Umetsu, Dale T

    2013-12-01

    Peanut allergy is a major public health problem that affects 1% of the population and has no effective therapy. To examine the safety and efficacy of oral desensitization in peanut-allergic children in combination with a brief course of anti-IgE mAb (omalizumab [Xolair]). We performed oral peanut desensitization in peanut-allergic children at high risk for developing significant peanut-induced allergic reactions. Omalizumab was administered before and during oral peanut desensitization. We enrolled 13 children (median age, 10 years), with a median peanut-specific IgE level of 229 kU(A)/L and a median total serum IgE level of 621 kU/L, who failed an initial double-blind placebo-controlled food challenge at peanut flour doses of 100 mg or less. After pretreatment with omalizumab, all 13 subjects tolerated the initial 11 desensitization doses given on the first day, including the maximum dose of 500 mg peanut flour (cumulative dose, 992 mg, equivalent to >2 peanuts), requiring minimal or no rescue therapy. Twelve subjects then reached the maximum maintenance dose of 4000 mg peanut flour per day in a median time of 8 weeks, at which point omalizumab was discontinued. All 12 subjects continued on 4000 mg peanut flour per day and subsequently tolerated a challenge with 8000 mg peanut flour (equivalent to about 20 peanuts), or 160 to 400 times the dose tolerated before desensitization. During the study, 6 of the 13 subjects experienced mild or no allergic reactions, 5 subjects had grade 2 reactions, and 2 subjects had grade 3 reactions, all of which responded rapidly to treatment. Among children with high-risk peanut allergy, treatment with omalizumab may facilitate rapid oral desensitization and qualitatively improve the desensitization process. Copyright © 2013 American Academy of Allergy, Asthma & Immunology. Published by Mosby, Inc. All rights reserved.

  4. Translucency and color match with a shade guide of esthetic brackets with the aid of a spectroradiometer.

    Science.gov (United States)

    Lee, Yong-Keun; Bin, Yu

    2016-01-01

    Since the color of esthetic brackets should match that of teeth, the aims of this study were to determine the color and translucency of esthetic brackets by means of the clinically relevant use of a spectroradiometer, and to compare the color of brackets with that of a commercial shade guide. The color of central and tie-wing regions of four plastic and four ceramic brackets was measured according to the CIE L*a*b* color scale over white and black backgrounds. Brackets were classified into five groups based on their composition. The color of Vitapan Classical Shade Guide tabs was also measured. Translucency parameter (TP) and contrast ratio (CR) were calculated to determine translucency. Color differences between brackets and the shade guide tabs were 10.4 - 34.5 ∆E*ab units. TP and CR values for the central region were 16.4 - 27.7 and 0.38 - 0.58, whereas for the tie-wings they were 24.0 - 39.9 and 0.25 - 0.45, respectively. The color coordinates, TP and CR values were significantly influenced by bracket composition and brand (p brackets investigated herein showed unacceptable color differences (∆E*ab > 5.5) compared with the shade guide tabs. Differences in the translucency of brackets by brand were within the visually perceptible range (∆CR > 0.07). Therefore, brackets showing the best matching performance for each case should be selected considering esthetic and functional demands.

  5. The effect of ZnO nanoparticle coating on the frictional resistance between orthodontic wires and ceramic brackets

    Directory of Open Access Journals (Sweden)

    Ahmad

    2016-06-01

    Full Text Available Background. Any decrease in friction between orthodontic wire and bracket can accelerate tooth movement in the sliding technique and result in better control of anchorage. This study was carried out to evaluate frictional forces by coating orthodontic wires and porcelain brackets with zinc oxide nanoparticles (ZnO. Methods. In this in vitro study, we evaluated a combination of 120 samples of 0.019×0.025 stainless steel (SS orthodontic wires and 22 mil system edgewise porcelain brackets with and without spherical zinc oxide nanoparticles. Spherical ZnO nanoparticles were deposited on wires and brackets by immersing them in ethanol solution and SEM (scanning electron microscope evaluation confirmed the presence of the ZnO coating. The frictional forces were calculated between the wires and brackets in four groups: group ZZ (coated wire and bracket, group OO (uncoated wire and bracket, group ZO (coated wire and uncoated bracket and group OZ (uncoated wire and coated bracket. Kolmogorov-Smirnov, Mann-Whitney and Kruskal-Wallis tests were used for data analysis. Results. The frictional force in ZZ (3.07±0.4 N was the highest (P <0.05, and OZ (2.18±0.5 N had the lowest amount of friction (P <0.05 among the groups. There was no significant difference in frictional forces between the ZO and OO groups (2.65±0.2 and 2.70±0.2 N, respectively. Conclusion. Coating of porcelain bracket surfaces with ZnO nanoparticles can decrease friction in the sliding technique, and wire coating combined with bracket coating is not recommended due to its effect on friction.

  6. The influence of size and structure of metal orthodontic bracket base on bond strength on tooth enamel

    Directory of Open Access Journals (Sweden)

    Mitić Vladimir

    2009-01-01

    Full Text Available Introduction. The factors which may influence the bond strength of the applied orthodontic brackets on the tooth surface are the size and structure of the bracket base. Objective. The aim of the paper was to investigate the influence of size and shape of different types of brackets on bond strength on the enamel and analyze the remaining quality of adhesive material on the tooth surface after debonding of orthodontic brackets (adhesive remnant index - ARI. Methods. In this study, three types of metal brackets of different sizes and shapes of Dentaurum manufacturer were used (Utratrimm, Equilibrium 2, Discovery, Dentaurum, Inspringen, Germany. The brackets were applied onto the middle part of the anatomic crowns of buccal surfaces of 30 premolars extracted for orthodontic reasons. In addition, the pre-treatment of teeth by 37% orthophosphoric acid and adhesive material System1+ (Dentaurum, Germany were used. Results. The mean value of the bonded brackets bond strength of Discovery type after debonding was 8.67±0.32 MPa, while the value of the bonded brackets bond strength of Equilibrium 2 type amounted to 8.62±0.22 MPa. The value of the bonded brackets bond strength of Ultratrimm type after debonding was 8.22±0.49 MPa. There were no statistical differences in the values of bond strength regarding all three groups of the investigated orthodontic brackets (F=4.56; p<0.05. Conclusion. The base size and design of metal orthodontic brackets did not play a significant role in bond strength, while the values of ARI index were identical in all three investigated groups.

  7. Evolving paradigms for desensitization in managing broadly HLA sensitized transplant candidates.

    Science.gov (United States)

    Reinsmoen, Nancy L; Lai, Chi-Hung; Vo, Ashley; Jordan, Stanley C

    2012-04-01

    The broadly human leukocyte antigen (HLA) sensitized patient awaiting organ transplantation remains a persistent and significant problem for transplant medicine. Sensitization occurs as a consequence of exposure to HLA antigens through pregnancy, blood and platelet transfusions, and previous transplants. Early experience with desensitization protocols coupled with improved diagnostics for donor-specific antibodies (DSAs) and renal pathology have greatly improved transplant rates and outcomes for patients once considered un-transplantable or at high risk for poor outcomes. More recent advances have occurred through implementation of a national allocation system requiring the entering of unacceptable antigens that reduces the rate of crossmatch positivity. Current desensitization therapies include high-dose intravenous immunoglobulin (IVIG), plasma exchange (PLEX) with low-dose IVIG, and IVIG combined with rituximab. Developing therapies include proteasome inhibitors aimed at plasma cells and modifiers of complement-mediated injury. Here we discuss the important advancements in desensitization including defining the risk for antibody-mediated rejection prior to transplantation and the evolution of therapies aimed at reducing the impact of antibody injury on allografts.

  8. Quadratic brackets from symplectic forms

    International Nuclear Information System (INIS)

    Alekseev, Anton Yu.; Todorov, Ivan T.

    1994-01-01

    We give a physicist oriented survey of Poisson-Lie symmetries of classical systems. We consider finite-dimensional geometric actions and the chiral WZNW model as examples for the general construction. An essential point is the appearance of quadratic Poisson brackets for group-like variables. It is believed that upon quantization they lead to quadratic exchange algebras. ((orig.))

  9. Desensitizing Addiction : Using Eye Movements to Reduce the Intensity of Substance-Related Mental Imagery and Craving

    NARCIS (Netherlands)

    Littel, M.; van den Hout, M.A.; Engelhard, I.M.

    2016-01-01

    Eye movement desensitization and reprocessing (EMDR) is an effective treatment for posttraumatic stress disorder. During this treatment, patients recall traumatic memories while making horizontal eye movements (EM). Studies have shown that EM not only desensitize negative memories but also positive

  10. Shear bond strength of orthodontic brackets and disinclusion buttons: effect of water and saliva contamination.

    Science.gov (United States)

    Sfondrini, Maria Francesca; Fraticelli, Danilo; Gandini, Paola; Scribante, Andrea

    2013-01-01

    The aim of this study was to assess the effect of water and saliva contamination on the shear bond strength and failure site of orthodontic brackets and lingual buttons. 120 bovine permanent mandibular incisors were randomly divided into 6 groups of 20 specimens each. Both orthodontic brackets and disinclusion buttons were tested under three different enamel surface conditions: (a) dry, (b) water contamination, and (c) saliva contamination. Brackets and buttons were bonded to the teeth and subsequently tested using a Instron universal testing machine. Shear bond strength values and adhesive failure rate were recorded. Statistical analysis was performed using ANOVA and Tukey tests (strength values) and Chi squared test (ARI Scores). Noncontaminated enamel surfaces showed the highest bond strengths for both brackets and buttons. Under water and saliva contamination orthodontic brackets groups showed significantly lower shear strengths than disinclusion buttons groups. Significant differences in debond locations were found among the groups under the various enamel surface conditions. Water and saliva contamination of enamel during the bonding procedure lowers bond strength values, more with orthodontic brackets than with disinclusion buttons.

  11. Influence of ligation method on friction resistance of lingual brackets with different second-order angulations: an in vitro study.

    Science.gov (United States)

    Pereira, Graziane Olímpio; Gimenez, Carla Maria Melleiro; Prieto, Lucas; Prieto, Marcos Gabriel do Lago; Basting, Roberta Tarkany

    2016-01-01

    To evaluate stainless steel archwire static friction in active and passive self-ligating lingual and conventional brackets with second-order angulations. Two conventional lingual brackets for canines (STb light/Ormco; PSWb/Tecnident), and two self-ligating brackets, one active (In-Ovation L/GAC) and the other passive (3D/ Forestadent), were evaluated. A stainless steel archwire was used at 0°, 3° and 5° angulations. Metal ligatures, conventional elastic ligatures, and low friction elastic ligatures were also tested. A universal testing machine applied friction between brackets and wires, simulating sliding mechanics, to produce 2-mm sliding at 3 mm/minute speed. Two-way analysis of variance demonstrated a significant effect of the interaction between brackets and angulations (p frictional resistance values were observed at 5° angulation for In-Ovation L, PSWb bracket with non conventional ligature, and STb bracket with metal ligature. As for 3D, PSWb with conventional or metal ligatures, and STb brackets with non conventional ligature, showed significantly lower static frictional resistance with 0° angulation. At 0° angulation, STb brackets with metal ties, In-Ovation L brackets and 3D brackets had the lowest frictional resistance. As the angulation increased from 0° to 3°, static friction resistance increased. When angulation increased from 3° to 5°, static friction resistance increased or remained the same. Self-ligating 3D and In-Ovation L brackets, as well as conventional STb brackets, seem to be the best option when sliding mechanics is used to perform lingual orthodontic treatment.

  12. Factors affecting the shear bond strength of metal and ceramic brackets bonded to different ceramic surfaces.

    Science.gov (United States)

    Abu Alhaija, Elham S J; Abu AlReesh, Issam A; AlWahadni, Ahed M S

    2010-06-01

    The aims of this study were to evaluate the shear bond strength (SBS) of metal and ceramic brackets bonded to two different all-ceramic crowns, IPS Empress 2 and In-Ceram Alumina, to compare the SBS between hydrofluoric acid (HFA), phosphoric acid etched, and sandblasted, non-etched all-ceramic surfaces. Ninety-six all-ceramic crowns were fabricated resembling a maxillary left first premolar. The crowns were divided into eight groups: (1) metal brackets bonded to sandblasted 9.6 per cent HFA-etched IPS Empress 2 crowns; (2) metal brackets bonded to sandblasted 9.6 per cent HFA-etched In-Ceram crowns; (3) ceramic brackets bonded to sandblasted 9.6 per cent HFA-etched IPS Empress 2 crowns; (4) ceramic brackets bonded to sandblasted 9.6 per cent HFA-etched In-Ceram crowns; (5) metal brackets bonded to sandblasted 37 per cent phosphoric acid-etched IPS Empress 2 crowns; (6) metal brackets bonded to sandblasted 37 per cent phosphoric acid-etched In-Ceram crowns; (7) metal brackets bonded to sandblasted, non-etched IPS Empress 2 crowns; and (8) metal brackets bonded to sandblasted, non-etched In-Ceram crowns. Metal and ceramic orthodontic brackets were bonded using a conventional light polymerizing adhesive resin. An Instron universal testing machine was used to determine the SBS at a crosshead speed of 0.1 mm/minute. Comparison between groups was performed using a univariate general linear model and chi-squared tests. The highest mean SBS was found in group 3 (120.15 +/- 45.05 N) and the lowest in group 8 (57.86 +/- 26.20 N). Of all the variables studied, surface treatment was the only factor that significantly affected SBS (P Empress 2 and In-Ceram groups.

  13. Fluoride releasing and enamel demineralization around orthodontic brackets by fluoride-releasing composite containing nanoparticles.

    Science.gov (United States)

    Melo, Mary A S; Morais, Weslanny A; Passos, Vanara F; Lima, Juliana P M; Rodrigues, Lidiany K A

    2014-05-01

    Fluoride-containing materials have been suggested to control enamel demineralization around orthodontic brackets during the treatment with fixed appliances. The improvement of their properties has been made through innovations, such as the application of nanotechnology by incorporation of nanofillers. This in vitro study evaluated the capacity of fluoride releasing and enamel demineralization inhibition of fluoride-releasing nanofilled cement around orthodontic brackets using an artificial caries biofilm model. Forty bovine enamel discs were selected by evaluating surface microhardness and randomized into four groups (n = 10): non-fluoride-releasing microfilled composite, fluoride-releasing microfilled composite, resin-modified glass ionomer cement (RMGI), and fluoride-releasing nanofilled composite (FN). After brackets bonding in each disc, the specimens were subjected to a cariogenic challenge through a Streptococcus mutans biofilm model. After the experimental period, the biofilm formed around the brackets was collected for fluoride analysis and the mineral loss around the brackets was determined by integrated demineralization via cross-sectional microhardness measurement at 20 and 70 μm from the bracket margin. Additionally, samples of each group were subjected to energy-dispersive X-ray spectroscopy (EDX) analysis examined under a scanning electron microscopy (SEM). ANOVA followed by Tukey test were applied for fluoride concentration and mineral loss data, respectively. At both distances, only RMGI statistically differed from the other groups presenting the lowest demineralization, although there was a trend to a lower demineralization of enamel around brackets in FN group. Similar condition was found to fluoride concentration and EDX/SEM analysis. Under the cariogenic exposure condition of this study, the fluoride-releasing nanofilled material had similar performance to fluoride-releasing microfilled materials. The presence of nanofillers in the fluoride

  14. Outcomes of Highly Sensitized Patients Undergoing Simultaneous Liver and Kidney Transplantation: A Single-Center Experience With Desensitization.

    Science.gov (United States)

    Steggerda, J A; Kang, A; Pan, S-H; Sundaram, V; Nissen, N N; Klein, A S; Todo, T; Annamalai, A; Vo, A; Jordan, S C; Kim, I K

    Preformed donor-specific human leukocyte antigen antibodies (DSAs) in patients undergoing simultaneous liver and kidney transplantation (SLKT) are an independent risk factor for poorer patient and renal allograft survival. The outcomes of patients highly sensitized (HS) against HLA antigens undergoing SLKT and select HS SLKT recipients undergoing desensitization at a high-volume desensitization center were investigated. Seventy-five patients undergoing SLKT at a high-volume desensitization center between January 1, 2001, and December 31, 2015, were retrospectively reviewed. HS patients were defined by panel-reactive antibody (PRA) >30% (n = 17 patients), 11 of whom received pre- or perioperative desensitization with high-dose intravenous immunoglobulin (IVIG) ± rituximab. HS patients had significantly higher class I and class II PRA (class I = 41.3% ± 40.0% vs 2.5% ± 6.3%; class II = 45.7% ± 36.4% vs 1.0% ± 2.9%; P Desensitization in select HS SLKT patients was well tolerated but did not improve patient and allograft survival or significantly curtail rejection. HS SLKT recipients demonstrated increased allograft rejection, particularly CMR, but patient and graft survival were not impacted in the first year post-transplant. Select HS SLKT patients tolerated desensitization with high-dose IVIG ± rituximab and may have received additional immunoprotection against ABMR but survival was not affected. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Null canonical formalism 1, Maxwell field. [Poisson brackets, boundary conditions

    Energy Technology Data Exchange (ETDEWEB)

    Wodkiewicz, K [Warsaw Univ. (Poland). Inst. Fizyki Teoretycznej

    1975-01-01

    The purpose of this paper is to formulate the canonical formalism on null hypersurfaces for the Maxwell electrodynamics. The set of the Poisson brackets relations for null variables of the Maxwell field is obtained. The asymptotic properties of the theory are investigated. The Poisson bracket relations for the news-functions of the Maxwell field are computed. The Hamiltonian form of the asymptotic Maxwell equations in terms of these news-functions is obtained.

  16. Excessive users of violent video games do not show emotional desensitization: an fMRI study.

    Science.gov (United States)

    Szycik, Gregor R; Mohammadi, Bahram; Hake, Maria; Kneer, Jonas; Samii, Amir; Münte, Thomas F; Te Wildt, Bert T

    2017-06-01

    Playing violent video games have been linked to long-term emotional desensitization. We hypothesized that desensitization effects in excessive users of violent video games should lead to decreased brain activations to highly salient emotional pictures in emotional sensitivity brain regions. Twenty-eight male adult subjects showing excessive long-term use of violent video games and age and education matched control participants were examined in two experiments using standardized emotional pictures of positive, negative and neutral valence. No group differences were revealed even at reduced statistical thresholds which speaks against desensitization of emotion sensitive brain regions as a result of excessive use of violent video games.

  17. Desensitization and recovery of metastable intermolecular composites

    Science.gov (United States)

    Busse, James R [South Fork, CO; Dye, Robert C [Los Alamos, NM; Foley, Timothy J [Los Alamos, NM; Higa, Kelvin T [Ridgecrest, CA; Jorgensen, Betty S [Jemez Springs, NM; Sanders, Victor E [White Rock, NM; Son, Steven F [Los Alamos, NM

    2010-09-07

    A method to substantially desensitize a metastable intermolecular composite material to electrostatic discharge and friction comprising mixing the composite material with an organic diluent and removing enough organic diluent from the mixture to form a mixture with a substantially putty-like consistency, as well as a concomitant method of recovering the metastable intermolecular composite material.

  18. Prospective iterative trial of proteasome inhibitor-based desensitization.

    Science.gov (United States)

    Woodle, E S; Shields, A R; Ejaz, N S; Sadaka, B; Girnita, A; Walsh, R C; Alloway, R R; Brailey, P; Cardi, M A; Abu Jawdeh, B G; Roy-Chaudhury, P; Govil, A; Mogilishetty, G

    2015-01-01

    A prospective iterative trial of proteasome inhibitor (PI)-based therapy for reducing HLA antibody (Ab) levels was conducted in five phases differing in bortezomib dosing density and plasmapheresis timing. Phases included 1 or 2 bortezomib cycles (1.3 mg/m(2) × 6-8 doses), one rituximab dose and plasmapheresis. HLA Abs were measured by solid phase and flow cytometry (FCM) assays. Immunodominant Ab (iAb) was defined as highest HLA Ab level. Forty-four patients received 52 desensitization courses (7 patients enrolled in multiple phases): Phase 1 (n = 20), Phase 2 (n = 12), Phase 3 (n = 10), Phase 4 (n = 5), Phase 5 (n = 5). iAb reductions were observed in 38 of 44 (86%) patients and persisted up to 10 months. In Phase 1, a 51.5% iAb reduction was observed at 28 days with bortezomib alone. iAb reductions increased with higher bortezomib dosing densities and included class I, II, and public antigens (HLA DRβ3, HLA DRβ4 and HLA DRβ5). FCM median channel shifts decreased in 11/11 (100%) patients by a mean of 103 ± 54 mean channel shifts (log scale). Nineteen out of 44 patients (43.2%) were transplanted with low acute rejection rates (18.8%) and de novo DSA formation (12.5%). In conclusion, PI-based desensitization consistently and durably reduces HLA Ab levels providing an alternative to intravenous immune globulin-based desensitization. © Copyright 2014 The American Society of Transplantation and the American Society of Transplant Surgeons.

  19. Voltage quality: solutions of desensitization; Qualite de la tension: les solutions de desensibilisation

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1999-10-01

    The occurrence of voltage drops and cuts can lead to major malfunctions in electrical installations with sometimes important economical impacts. Thus, the use of solutions of desensitization are needed to avoid such disturbances. This technical paper gives a summary of the basic solutions elaborated by Electricite de France (EdF) with the participation of electrical engineering associations in order to solve the problems encountered in existing installations and to provide specifications for the newly designed installations: the desensitization process (origin of voltage drops, solutions, costs), the diagnosis of industrial installations (identification, quantitative analysis and recording of disturbances, complementary informations, causes, economical impact, solutions, costs, remedial action), the general and specific solutions of desensitization (instrumentation and control systems, switches, relays, motors, speed regulators and variators), specific solutions for computerized and electronic systems, and the role of batteries. (J.S.)

  20. Investigation into the effects of stainless steel ligature ties on the mechanical characteristics of conventional and self-ligated brackets subjected to torque.

    Science.gov (United States)

    Al Fakir, Hussam; Carey, Jason P; Melenka, Garrett W; Nobes, David S; Heo, Giseon; Major, Paul W

    2014-09-01

    Torque is applied to orthodontic brackets in order to alter the buccal-lingual angulation of a tooth. One factor that can affect torque is the ligation mode used to retain the archwire in the bracket slot. The objective of this study was to investigate the effects of stainless steel ligation on torque expression and bracket deformation. This study utilized 60 upper right central incisor Damon Q brackets and 60 Ormco Orthos Twin brackets. The brackets used in this study were subdivided into four groups: (1) Damon Q ligated with SS ligature; (2) Damon Q with the sliding bracket door; (3) Orthos Twin bracket ligated with SS wire; and (4) Orthos Twin ligated with elastic ties. All brackets were tested using an orthodontic torque simulating device that applied archwire rotation from 0° to 45°. All brackets ligated with stainless steel ties exhibited greater torque expression and less deformation than brackets without stainless steel ties. As well, Damon Q brackets exhibit less bracket deformation than Orthos Twin brackets. Stainless steel ties can reduce the amount of plastic deformation for both types of brackets used in this study. © 2014 British Orthodontic Society.

  1. Effects of chlorhexidine (gel) application on bacterial levels and orthodontic brackets during orthodontic treatment.

    Science.gov (United States)

    Al-Bazi, Samar M; Abbassy, Mona A; Bakry, Ahmed S; Merdad, Leena A; Hassan, Ali H

    2016-01-01

    The objectives of this study were to evaluate the effects of applying 0.50% chlorhexidine (CHX) gel using the dental drug delivery system (3DS) on salivary Streptococcus mutans (S. mutans) and on the surface topography of metal and ceramic orthodontic brackets. The study involved 20 orthodontic patients with high levels of salivary S. mutans. The patients were treated with professional mechanical tooth cleaning followed by application of 0.50% CHX using individual trays (3DS). Salivary S. mutans levels were repeatedly measured 1, 2, 4, and 8 weeks post-treatment. In vitro study utilized forty ceramic and metallic brackets that were immersed in 0.50% CHX gel for 10 min, whereas another untreated forty brackets served as controls. The frictional resistances of stainless steel wires to the brackets before and after CHX treatment were recorded using a universal testing machine. Scanning electron microscopy was used to compare changes in the surface topography of brackets. Statistical analyses were used to determine the effect of CHX on bacterial count and to evaluate the effect of CHX on frictional resistance. According to the results of this study, S. mutans levels were reduced significantly (P brackets before or after application of CHX. (J Oral Sci 58, 35-42, 2016).

  2. Comparison of Shear Bond Strength of RMGI and Composite Resin for Orthodontic Bracket Bonding

    Science.gov (United States)

    Yassaei, Soghra; Davari, Abdolrahim; Goldani Moghadam, Mahjobeh; Kamaei, Ahmad

    2014-01-01

    Objective: The aim of this study was to compare the shear bond strength (SBS) of resin modified glass ionomer (RMGI) and composite resin for bonding metal and ceramic brackets. Materials and Methods: Eighty-eight human premolars extracted for orthodontic purposes were divided into 4 groups (n=22). In groups 1 and 2, 22 metal and ceramic brackets were bonded using composite resin (Transbond XT), respectively. Twenty-two metal and ceramic brackets in groups 3 and 4, respectively were bonded using RMGI (Fuji Ortho LC, Japan). After photo polymerization, the teeth were stored in water and thermocycled (500 cycles between 5° and 55°). The SBS value of each sample was determined using a Universal Testing Machine. The amount of residual adhesive remaining on each tooth was evaluated under a stereomicroscope. Statistical analyses were done using two-way ANOVA. Results: RMGI bonded brackets had significantly lower SBS value compared to composite resin bonded groups. No statistically significant difference was observed between metal and ceramic brackets bonded with either the RMGI or composite resin. The comparison of the adhesive remnant index (ARI) scores between the groups indicated that the bracket failure mode was significantly different among groups (Porthodontic bonding purposes; however the provided SBS is still within the clinically acceptable range. PMID:25628663

  3. Outcome after Desensitization in HLA or ABO-Incompatible Kidney Transplant Recipients: A Single Center Experience.

    Science.gov (United States)

    Kauke, Teresa; Klimaschewski, Sandra; Schoenermarck, Ulf; Fischereder, Michael; Dick, Andrea; Guba, Markus; Stangl, Manfred; Werner, Jens; Meiser, Bruno; Habicht, Antje

    2016-01-01

    The shortage of deceased donors led to an increase of living donor kidney (LDK) transplantations performed in the presence of donor-specific antibodies (DSA) or ABO incompatibility (ABOi) using various desensitization protocols. We herein analyzed 26 ABOi and 8 Luminex positive DSA patients who were successfully desensitized by anti-CD20, antigen-specific immunoadsorption and/or plasmapheresis to receive an LDK transplant. Twenty LDK recipients with non-donor-specific HLA-antibodies (low risk) and 32 without anti-HLA antibodies (no risk) served as control groups. 1-year graft survival rate and renal function was similar in all 4 groups (creatinine: 1.63 ± 0.5 vs 1.78 ± 0.6 vs 1.64 ± 0.5 vs 1.6 ± 0.3 mg/dl in ABOi, DSA, low risk and no risk group). The incidence of acute T-cell mediated rejections did not differ between the 4 groups (15% vs 12, 5% vs 15% vs 22% in ABOi, DSA, low risk and no risk), while antibody-mediated rejections were only found in the DSA (25%) and ABOi (7.5%) groups. Incidence of BK nephropathy (BKVN) was significantly more frequent after desensitization as compared to controls (5/34 vs 0/52, p = 0.03). We demonstrate favorable short-term allograft outcome in LDK transplant recipients after desensitization. However, the desensitization was associated with an increased risk of BKVN.

  4. Effects of self-ligating and conventional brackets on halitosis and periodontal conditions.

    Science.gov (United States)

    Kaygisiz, Emine; Uzuner, Fatma Deniz; Yuksel, Sema; Taner, Levent; Çulhaoğlu, Rana; Sezgin, Yasemin; Ateş, Can

    2015-05-01

    To evaluate the effects of fixed orthodontic treatment with steel-ligated conventional brackets and self-ligating brackets on halitosis and periodontal health. Sixty patients, at the permanent dentition stage aged 12 to 18 years, who had Angle Class I malocclusion with mild-to-moderate crowding were randomly selected. Inclusion criteria were nonsmokers, without systematic disease, and no use of antibiotics and oral mouth rinses during the 2-month period before the study. The patients were subdivided into three groups randomly: the group treated with conventional brackets (group 1, n  =  20) ligated with steel ligature wires, the group treated with self-ligating brackets (group 2, n  =  20), and the control group (group 3, n  =  20). The periodontal records were obtained 1 week before bonding (T1), immediately before bonding (T2), 1 week after bonding (T3), 4 weeks after bonding (T4), and 8 weeks after bonding (T5). Measurements of the control group were repeated within the same periods. The volatile sulfur components determining halitosis were measured with the Halimeter at T2, T3, T4, and T5. A two-way repeated measures of analysis of variance (ANOVA) was used to compare the groups statistically. No statistically significant group × time interactions were found for plaque index, gingival index, pocket depth, bleeding on probing, and halitosis, which means three independent groups change like each other by time. The risk of tongue coating index (TCI) being 2 was 10.2 times higher at T1 than at T5 (P brackets do not have an advantage over conventional brackets with respect to periodontal status and halitosis.

  5. Desensitizing Children's Emotional Reactions to the Mass Media.

    Science.gov (United States)

    Wilson, Barbara J.

    1989-01-01

    Assesses effectiveness of two desensitization strategies for reducing children's emotional reactions to mass media. Examines children having passive exposure, modeled exposure, or no exposure to lizards before watching a horror movie involving lizards. Finds that modeled exposure decreases emotional reactions and negative interpretations, whereas…

  6. Modified precision lingual bonding technique: A step-wise approach with torque angulation device-bracket positioning device

    Directory of Open Access Journals (Sweden)

    Rosaline Tina Paul

    2017-01-01

    Full Text Available Objectives: Contemporary preadjusted edgewise appliance is all about the precision in bracket design, prescription and positioning in addition to the orthodontist's skill and training. However, achieving it is a bigger challenge as the anatomy of the lingual surface of a tooth is uneven, dissimilar, and moreover the tooth alignment on the lingual surface is variant. Thus, the need for an accurate method of bracket positioning with predetermined torque and angulation incorporated in the brackets according to the patients' need is of key importance. Materials and Methods: A TAD-BPD machine used to enhance the accuracy of bracket positioning and bioplast accurate tray transfer technique was used. Results: A step-wise procedures in bracket positioning and fabricating an indirect bonding tray for lingual orthodontics using the torque angulation device-bracket positioning device. Conclusions: This technique facilitated unhindered bonding even in severely crowded cases and easy rebonding during mid-treatment stages.

  7. Adhesion of mutans streptococci to self-ligating ceramic brackets: in vivo quantitative analysis with real-time polymerase chain reaction.

    Science.gov (United States)

    Jung, Woo-Sun; Yang, Il-Hyung; Lim, Won Hee; Baek, Seung-Hak; Kim, Tae-Woo; Ahn, Sug-Joon

    2015-12-01

    To analyze in vivo mutans streptococci (MS) adhesion to self-ligating ceramic brackets [Clarity-SL (CSL) and Clippy-C (CC)] and the relationships between bacterial adhesion and oral hygiene indices. Four central incisor brackets from the maxilla and mandible were collected from 40 patients (20 patients per each bracket type) at debonding immediately after plaque and gingival indices were measured. Adhesions of Streptococcus mutans, S. sobrinus, and total bacteria were quantitatively determined using real-time polymerase chain reaction after genomic DNA was extracted. Factorial analysis of variance was used to analyze bacterial adhesion to the brackets with respect to the bracket type and jaw position. Correlation coefficients were calculated to determine the relationships of bacterial adhesion to oral hygiene indices. Adhesion of total bacteria and S. mutans to CSL was higher than that to CC (P brackets was higher than that to the maxillary ones (P brackets were higher than that in the mandibular ones (P brackets and jaw positions. Interestingly, no significant relationships were found between bacterial adhesions and oral hygiene indices. Complex bracket configurations may significantly influence bacterial adhesion to orthodontic brackets. Further in vivo study using bracket raw materials will help to define the relationships between bacteria adhesion and enamel demineralization. Because oral hygiene indices were not significantly correlated with adhesions of MS to self-ligating ceramic brackets, careful examinations around the brackets should be needed to prevent enamel demineralization, regardless of oral hygiene status. © The Author 2015. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  8. A role for inflammatory mediators in heterologous desensitization of CysLT1 receptor in human monocytes

    Science.gov (United States)

    Capra, Valérie; Accomazzo, Maria Rosa; Gardoni, Fabrizio; Barbieri, Silvia; Rovati, G. Enrico

    2010-01-01

    Cysteinyl-leukotrienes (cysteinyl-LT) are rapidly generated at sites of inflammation and, in addition to their role in asthma, rhinitis, and other immune disorders, are increasingly regarded as significant inflammatory factors in cancer, gastrointestinal, cardiovascular diseases. We recently demonstrated that in monocyte/macrophage–like U937 cells, extracellular nucleotides heterologously desensitize CysLT1 receptor (CysLT1R)-induced Ca2+ transients. Given that monocytes express a number of other inflammatory and chemoattractant receptors, this study was aimed at characterizing transregulation between these different stimuli. We demonstrate that in U937 cells and in primary human monocytes, a series of inflammatory mediators activating Gi-coupled receptor (FPR1, BLT1) desensitize CysLT1R-induced Ca2+ response unidirectionally through activation of PKC. Conversely, PAF-R, exclusively coupled to Gq, cross-desensitizes CysLT1R without the apparent involvement of any kinase. Interestingly, Gs-coupled receptors (β2AR, H1/2R, EP2/4R) are also able to desensitize CysLT1R response through activation of PKA. Heterologous desensitization seems to affect mostly the Gi-mediated signaling of the CysLT1R. The hierarchy of desensitization among agonists may be important for leukocyte signal processing at the site of inflammation. Considering that monocytes/macrophages are likely to be the major source of cysteinyl-LT in many immunological and inflammatory processes, shedding light on how their receptors are regulated will certainly help to better understand the role of these cells in orchestrating this complex network of integrated signals. PMID:19965602

  9. Comparison of Anxiety Management Training and Self-Control Desensitization.

    Science.gov (United States)

    Deffenbacher, Jerry L.; And Others

    1980-01-01

    Anxiety management training and self-control desensitization effectively reduced debilitating test anxiety and increased facilitating test anxiety. Follow-up demonstrated maintenance of debilitating test anxiety reduction. Subjects receiving treatment had significantly higher psychology grades. (Author)

  10. Evaluation of surface roughness of the bracket slot floor—a 3D perspective study

    Directory of Open Access Journals (Sweden)

    Chetankumar O. Agarwal

    2016-01-01

    Full Text Available Abstract Background An important constituent of an orthodontic appliance is orthodontic brackets. It is either the bracket or the archwire that slides through the bracket slot, during sliding mechanics. Overcoming the friction between the two surfaces demands an important consideration in an appliance design. The present study investigated the surface roughness of four different commercially available stainless steel brackets. Methods All tests were carried out to analyse quantitatively the morphological surface of the bracket slot floor with the help of scanning electron microscope (SEM machine and to qualitatively analyse the average surface roughness (Sa of the bracket slot floor with the help of a three-dimensional (3D non-contact optical surface profilometer machine. Results The SEM microphotographs were evaluated with the help of visual analogue scale, the surface roughness for group A = 0—very rough surface, group C = 1—rough surface, group B = 2—smooth surface, and group D = 3—very smooth surface. Surface roughness evaluation with the 3D non-contact optical surface profilometer machine was highest for group A, followed by group C, group B and group D. Groups B and D provided smooth surface roughness; however, group D had the very smooth surface with values 0.74 and 0.75 for mesial and distal slots, respectively. Conclusions Evaluation of surface roughness of the bracket slot floor with both SEM and profilometer machine led to the conclusion that the average surface roughness was highest for group A, followed by group C, group B and group D.

  11. A novel biomimetic orthodontic bonding agent helps prevent white spot lesions adjacent to brackets.

    Science.gov (United States)

    Manfred, Lauren; Covell, David A; Crowe, Jennifer J; Tufekci, Eser; Mitchell, John C

    2013-01-01

    To compare changes in enamel microhardness adjacent to orthodontic brackets after using bonding agents containing various compositions of bioactive glass compared to a traditional resin adhesive following a simulated caries challenge. Extracted human third molars (n  =  10 per group) had orthodontic brackets bonded using one of four novel bioactive glass (BAG)-containing orthodontic bonding agents (BAG-Bonds) or commercially available Transbond-XT. The four new adhesives contained BAG in varying percentages incorporated into a traditional resin monomer mixture. Teeth were cycled through low-pH demineralizing and physiologic-pH remineralizing solutions once each day over 14 days. Microhardness was measured on longitudinal sections of the teeth 100, 200, and 300 µm from the bracket edge and beneath the brackets, at depths of 25 to 200 µm from the enamel surface. Normalized hardness values were compared using three-way analysis of variance. Significantly less reduction in enamel microhardness was found with the experimental adhesives at depths of 25 and 50 µm at all distances from the bracket edge. In all groups, there were no significant changes in enamel microhardness past 125-µm depth. Results varied with the different BAG-Bonds, with 81BAG-Bond showing the smallest decrease in enamel microhardness. The BAG-Bonds tested in this study showed a reduction in the amount of superficial enamel softening surrounding orthodontic brackets compared to a traditional bonding agent. The results indicate that clinically, BAG-Bonds may aid in maintaining enamel surface hardness, therefore helping prevent white spot lesions adjacent to orthodontic brackets.

  12. Influence of the bracket on bonding and physical behavior of orthodontic resin cements.

    Science.gov (United States)

    Bolaños-Carmona, Victoria; Zein, Bilal; Menéndez-Núñez, Mario; Sánchez-Sánchez, Purificación; Ceballos-García, Laura; González-López, Santiago

    2015-01-01

    The aim of the study is to determine the influence of the type of bracket, on bond strength, microhardness and conversion degree (CD) of four resin orthodontic cements. Micro-tensile bond strength (µTBS) test between the bracket base and the cement was carried out on glass-hour-shaped specimens (n=20). Vickers Hardness Number (VHN) and micro-Raman spectra were recorded in situ under the bracket base. Weibull distribution, ANOVA and non-parametric test were applied for data analysis (pcement showing the worst performance. The CD was from 80% to 62.5%.

  13. Comparison between two methods for resin removing after bracket debonding

    OpenAIRE

    Marchi, Rodrigo De; Marchi, Luciana Manzotti De; Terada, Raquel Sano Suga; Terada, Hélio Hissashi

    2012-01-01

    OBJECTIVE: The aim of this study was to assess - using scanning electron microscopy (SEM) - the effectiveness of two abrasive discs, one made from silicon and one from aluminum oxide, in removing adhesive remnants (AR) after debonding orthodontic brackets. METHODS: Ten randomly selected bovine teeth were used, i.e., 2 in the control group, and the other 8 divided into two groups, which had orthodontic brackets bonded to their surface with Concise Orthodontic Adhesive (3M). The following metho...

  14. Orthodontic bracket bonding without previous adhesive priming: A meta-regression analysis.

    Science.gov (United States)

    Altmann, Aline Segatto Pires; Degrazia, Felipe Weidenbach; Celeste, Roger Keller; Leitune, Vicente Castelo Branco; Samuel, Susana Maria Werner; Collares, Fabrício Mezzomo

    2016-05-01

    To determine the consensus among studies that adhesive resin application improves the bond strength of orthodontic brackets and the association of methodological variables on the influence of bond strength outcome. In vitro studies were selected to answer whether adhesive resin application increases the immediate shear bond strength of metal orthodontic brackets bonded with a photo-cured orthodontic adhesive. Studies included were those comparing a group having adhesive resin to a group without adhesive resin with the primary outcome measurement shear bond strength in MPa. A systematic electronic search was performed in PubMed and Scopus databases. Nine studies were included in the analysis. Based on the pooled data and due to a high heterogeneity among studies (I(2)  =  93.3), a meta-regression analysis was conducted. The analysis demonstrated that five experimental conditions explained 86.1% of heterogeneity and four of them had significantly affected in vitro shear bond testing. The shear bond strength of metal brackets was not significantly affected when bonded with adhesive resin, when compared to those without adhesive resin. The adhesive resin application can be set aside during metal bracket bonding to enamel regardless of the type of orthodontic adhesive used.

  15. Transparent magnesium aluminate spinel: a prospective biomaterial for esthetic orthodontic brackets.

    Science.gov (United States)

    Krishnan, Manu; Tiwari, Brijesh; Seema, Saraswathy; Kalra, Namitha; Biswas, Papiya; Rajeswari, Kotikalapudi; Suresh, Madireddy Buchi; Johnson, Roy; Gokhale, Nitin M; Iyer, Satish R; Londhe, Sanjay; Arora, Vimal; Tripathi, Rajendra P

    2014-11-01

    Adult orthodontics is recently gaining popularity due to its importance in esthetics, oral and general health. However, none of the currently available alumina or zirconia based ceramic orthodontic brackets meet the esthetic demands of adult patients. Inherent hexagonal lattice structure and associated birefringence limits the visible light transmission in polycrystalline alumina and make them appear white and non transparent. Hence focus of the present study was to assess the feasibility of using magnesium aluminate (MgAl2O4) spinel; a member of the transparent ceramic family for esthetic orthodontic brackets. Transparent spinel specimens were developed from commercially available white spinel powder through colloidal shaping followed by pressureless sintering and hot isostatic pressing at optimum conditions of temperature and pressure. Samples were characterized for chemical composition, phases, density, hardness, flexural strength, fracture toughness and optical transmission. Biocompatibility was evaluated with in-vitro cell line experiments for cytotoxicity, apoptosis and genotoxicity. Results showed that transparent spinel samples had requisite physico-chemical, mechanical, optical and excellent biocompatibility for fabricating orthodontic brackets. Transparent spinel developed through this method demonstrated its possibility as a prospective biomaterial for developing esthetic orthodontic brackets.

  16. Human leukocyte antigen genotypes and trial of desensitization in patients with oxcarbazepine-induced skin rash: a pilot study.

    Science.gov (United States)

    Lee, Bolyun; Yu, Hee Joon; Kang, Eun-Suk; Lee, Munhyang; Lee, Jeehun

    2014-08-01

    Skin rash associated with specific antiepileptic drugs occurs not infrequently and it usually necessitates discontinuation of the causative drugs. An alternative strategy is to desensitize the individual to the offending drug. We checked the human leukocyte antigen genotypes and conducted a pilot study to investigate the usefulness and safety of desensitization in pediatric patients with skin rash associated with oxcarbazepine. We enrolled 19 patients with epilepsy who had discontinued oxcarbazepine because of skin rash despite an initial good response and then became refractory to other antiepileptic drugs along with an individual with paroxysmal kinesigenic dyskinesia with a similar situation. High-resolution HLA-A and -B genotyping was performed to investigate the genetic risk. The desensitization began with 0.1 mg daily reaching 120 mg on the thirty-first day. Thereafter, the dose was increased at a rate of 12 mg/day. Nineteen patients completed the desensitization protocol to a target dosage over 2-5 months. Five patients developed itching and erythema during desensitization, but the symptoms disappeared after withholding a dose increment transiently. There were no human leukocyte antigen genotypes relevant to aromatic antiepileptic drug-induced severe hypersensitivity reactions. The seizure frequency was reduced to less than at baseline in 18 individuals. This study demonstrated 95% efficacy, including 42% seizure-free patients and the favorable tolerability of desensitization to oxcarbazepine in patients with intractable epilepsy and one patient with paroxysmal kinesigenic dyskinesia. Screening for sensitive human leukocyte antigen types and exclusion of severe hypersensitivity reactions should precede desensitization. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Aspirin allergy desensitization in cerebrovascular disease. A report of two cases, literature review and management guide for the neurointerventionalist.

    Science.gov (United States)

    Zuckerman, Scott L; Seder, David B; Tsujiura, Crystiana; Cushing, Deborah; Gallup, Holly; Mocco, J; Hanel, Richard A; Ecker, Robert D

    2014-01-01

    Aspirin (ASA) is the mainstay of treatment in cerebrovascular and systemic vascular disease. ASA hypersensitivity can pose a challenge to achieving optimum medical management prior to and after neurointerventional treatment. Desensitization to ASA is well described in the allergy and cardiovascular literature, but there are no similar discussions specific to neurointervention. The purpose of our study was to describe our experience with ASA hypersensitivity management and review the relevant literature. Two cases of patients with symptomatic cerebrovascular disease requiring neurointervention who were successfully desensitized to their ASA hypersensitivity prior to treatment are described. The subsequent literature is reviewed. Several ASA desensitization protocols exist and have been proven to successfully treat ASA hypersensitivity and allow for ASA therapy to be safely initiated. We describe several previously published protocols. ASA desensitization is a safe and simple way to manage ASA hypersensitivity. We provide comprehensive management guidelines for the neurointerventionalist engaging in ASA desensitization.

  18. Gingival crevicular fluid volume and periodontal parameters alterations after use of conventional and self-ligating brackets.

    Science.gov (United States)

    Bergamo, Ana Zn; Nelson-Filho, Paulo; Romano, Fábio L; da Silva, Raquel Ab; Saraiva, Maria Cp; da Silva, Lea Ab; Matsumoto, Mirian An

    2016-12-01

    The aim of this study was to evaluate the alterations on plaque index (PI), gingival index (GI), gingival bleeding index (GBI), and gingival crevicular fluid (GCF) volume after use of three different brackets types for 60 days. Setting Participants: The sample comprised 20 patients of both sexes aged 11-15 years (mean age: 13.3 years), with permanent dentition, adequate oral hygiene, and mild tooth crowding, overjet, and overbite. A conventional metallic bracket Gemini™, and two different brands of self-ligating brackets - In-Ovation ® R and SmartClip™ - were bonded to the maxillary incisors and canines. PI, GI, GBI scores, and GCF volume were measured before and 30 and 60 days after bonding of the brackets. Data were analysed statistically using non-parametric tests coefficient at a 5% significance level. There was no statistically significant correlation (P > 0.05) between tooth crowding, overjet, and overbite and the PI, GI, GBI scores, and GCF volume before bonding, indicating no influence of malocclusion on the clinical parameters. Regardless of the bracket design, no statistically significant difference (P > 0.05) was found for GI, GBI scores. PI and GCF volume showed a significant difference among the brackets in different periods. In pairwise comparisons a significant difference was observed when compared before with 60 days after bonding, for the teeth bonded with SmartClip™ self-ligating bracket, (PI P = 0.009; GCF volume P = 0.001). There was an increase in PI score and GCF volume 60 days after bonding of SmartClip™ self-ligating brackets, indicating the influence of bracket design on these clinical parameters.

  19. Planning Risk-Based SQC Schedules for Bracketed Operation of Continuous Production Analyzers.

    Science.gov (United States)

    Westgard, James O; Bayat, Hassan; Westgard, Sten A

    2018-02-01

    To minimize patient risk, "bracketed" statistical quality control (SQC) is recommended in the new CLSI guidelines for SQC (C24-Ed4). Bracketed SQC requires that a QC event both precedes and follows (brackets) a group of patient samples. In optimizing a QC schedule, the frequency of QC or run size becomes an important planning consideration to maintain quality and also facilitate responsive reporting of results from continuous operation of high production analytic systems. Different plans for optimizing a bracketed SQC schedule were investigated on the basis of Parvin's model for patient risk and CLSI C24-Ed4's recommendations for establishing QC schedules. A Sigma-metric run size nomogram was used to evaluate different QC schedules for processes of different sigma performance. For high Sigma performance, an effective SQC approach is to employ a multistage QC procedure utilizing a "startup" design at the beginning of production and a "monitor" design periodically throughout production. Example QC schedules are illustrated for applications with measurement procedures having 6-σ, 5-σ, and 4-σ performance. Continuous production analyzers that demonstrate high σ performance can be effectively controlled with multistage SQC designs that employ a startup QC event followed by periodic monitoring or bracketing QC events. Such designs can be optimized to minimize the risk of harm to patients. © 2017 American Association for Clinical Chemistry.

  20. Bracket formulations and energy- and helicity-preserving numerical methods for incompressible two-phase flows

    Science.gov (United States)

    Suzuki, Yukihito

    2018-03-01

    A diffuse interface model for three-dimensional viscous incompressible two-phase flows is formulated within a bracket formalism using a skew-symmetric Poisson bracket together with a symmetric negative semi-definite dissipative bracket. The budgets of kinetic energy, helicity, and enstrophy derived from the bracket formulations are properly inherited by the finite difference equations obtained by invoking the discrete variational derivative method combined with the mimetic finite difference method. The Cahn-Hilliard and Allen-Cahn equations are employed as diffuse interface models, in which the equalities of densities and viscosities of two different phases are assumed. Numerical experiments on the motion of periodic arrays of tubes and those of droplets have been conducted to examine the properties and usefulness of the proposed method.

  1. Equal-Time and Equal-Space Poisson Brackets of the N -Component Coupled NLS Equation

    International Nuclear Information System (INIS)

    Zhou Ru-Guang; Li Pei-Yao; Gao Yuan

    2017-01-01

    Two Poisson brackets for the N-component coupled nonlinear Schrödinger (NLS) equation are derived by using the variantional principle. The first one is called the equal-time Poisson bracket which does not depend on time but only on the space variable. Actually it is just the usual one describing the time evolution of system in the traditional theory of integrable Hamiltonian systems. The second one is equal-space and new. It is shown that the spatial part of Lax pair with respect to the equal-time Poisson bracket and temporal part of Lax pair with respect to the equal-space Poisson bracket share the same r-matrix formulation. These properties are similar to that of the NLS equation. (paper)

  2. Comparison of Antibacterial Effects of ZnO and CuO Nanoparticles Coated Brackets against Streptococcus Mutans.

    Science.gov (United States)

    Ramazanzadeh, Baratali; Jahanbin, Arezoo; Yaghoubi, Masoud; Shahtahmassbi, Nasser; Ghazvini, Kiarash; Shakeri, Mohammadtaghi; Shafaee, Hooman

    2015-09-01

    During the orthodontic treatment, microbial plaques may accumulate around the brackets and cause caries, especially in high-risk patients. Finding ways to eliminate this microbial plaque seems to be essential. The aim of this study was to compare the antibacterial effects of nano copper oxide (CuO) and nano zinc oxide (ZnO) coated brackets against Streptococcus mutans (S.mutans) in order to decrease the risk of caries around the orthodontic brackets during the treatment. Sixty brackets were coated with nanoparticles of ZnO (n=20), CuO (n=20) and CuO-ZnO (n=20). Twelve uncoated brackets constituted the control group. The brackets were bonded to the crowns of extracted premolars, sterilized and prepared for antimicrobial tests (S.mutans ATCC35668). The samples taken after 0, 2, 4, 6 and 24 hours were cultured on agar plates. Colonies were counted 24 hours after incubation. One-way ANOVA and Tukey tests were used for statistical analysis. In CuO and CuO-ZnO coated brackets, no colony growth was seen after two hours. Between 0-6 hours, the mean colony counts were not significantly different between the ZnO and the control group (p>0.05). During 6-24 hours, the growth of S.mutans was significantly reduced by ZnO nanoparticles in comparison with the control group (pbrackets have better antimicrobial effect on S.mutans than ZnO coated brackets.

  3. Shear Bond Strength of Orthodontic Brackets and Disinclusion Buttons: Effect of Water and Saliva Contamination

    Science.gov (United States)

    Sfondrini, Maria Francesca; Fraticelli, Danilo; Gandini, Paola

    2013-01-01

    Purpose. The aim of this study was to assess the effect of water and saliva contamination on the shear bond strength and failure site of orthodontic brackets and lingual buttons. Materials and Methods. 120 bovine permanent mandibular incisors were randomly divided into 6 groups of 20 specimens each. Both orthodontic brackets and disinclusion buttons were tested under three different enamel surface conditions: (a) dry, (b) water contamination, and (c) saliva contamination. Brackets and buttons were bonded to the teeth and subsequently tested using a Instron universal testing machine. Shear bond strength values and adhesive failure rate were recorded. Statistical analysis was performed using ANOVA and Tukey tests (strength values) and Chi squared test (ARI Scores). Results. Noncontaminated enamel surfaces showed the highest bond strengths for both brackets and buttons. Under water and saliva contamination orthodontic brackets groups showed significantly lower shear strengths than disinclusion buttons groups. Significant differences in debond locations were found among the groups under the various enamel surface conditions. Conclusions. Water and saliva contamination of enamel during the bonding procedure lowers bond strength values, more with orthodontic brackets than with disinclusion buttons. PMID:23762825

  4. Shear Bond Strength of Orthodontic Brackets and Disinclusion Buttons: Effect of Water and Saliva Contamination

    Directory of Open Access Journals (Sweden)

    Maria Francesca Sfondrini

    2013-01-01

    Full Text Available Purpose. The aim of this study was to assess the effect of water and saliva contamination on the shear bond strength and failure site of orthodontic brackets and lingual buttons. Materials and Methods. 120 bovine permanent mandibular incisors were randomly divided into 6 groups of 20 specimens each. Both orthodontic brackets and disinclusion buttons were tested under three different enamel surface conditions: (a dry, (b water contamination, and (c saliva contamination. Brackets and buttons were bonded to the teeth and subsequently tested using a Instron universal testing machine. Shear bond strength values and adhesive failure rate were recorded. Statistical analysis was performed using ANOVA and Tukey tests (strength values and Chi squared test (ARI Scores. Results. Noncontaminated enamel surfaces showed the highest bond strengths for both brackets and buttons. Under water and saliva contamination orthodontic brackets groups showed significantly lower shear strengths than disinclusion buttons groups. Significant differences in debond locations were found among the groups under the various enamel surface conditions. Conclusions. Water and saliva contamination of enamel during the bonding procedure lowers bond strength values, more with orthodontic brackets than with disinclusion buttons.

  5. Effect of the precrack preparation with an ultrasonic instrument on the ceramic bracket removal

    Directory of Open Access Journals (Sweden)

    Yen-Liang Chen

    2015-08-01

    Conclusion: The ultrasonic precrack preparation can significantly decrease the debonding force and may guide the bracket debonding through a favorable fracture plane without damage to either the bracket or the enamel.

  6. A comparative evaluation of the effect of dentin desensitizers on the retention of complete cast metal crowns

    Directory of Open Access Journals (Sweden)

    Saili M Chandavarkar

    2015-01-01

    Full Text Available Context: Desensitizers are used to reduce dentin hypersensitivity. They affect the surface texture of prepared dentin and may alter the retention of fixed restorations. Aims: The aim was to evaluate the effect of dentin desensitizers on the retention of complete cast metal crowns luted with glass ionomer cement. Subjects and Methods: Fifty freshly extracted human premolars were subjected to standardized tooth preparation (20° total convergence, 4 mm axial height with a computer numerically controlled machine. Individual cast metal crowns were fabricated from a base metal alloy. Dentin desensitizers included none (control, a glutaraldehyde (GLU based primer (Gluma desensitizer, casein phosphopeptide (CPP-amorphous calcium phosphate (ACP (GC Mousse, erbium, chromium: YSGG laser (Waterlase MD Turbo, Biolase and Pro-Argin (Colgate Sensitive Pro-Relief desensitizing polishing paste. After desensitization, crowns were luted with glass ionomer cement and kept for 48 h at 37°C in 100% relative humidity. The samples were tested using a universal testing machine by applying a load at a crosshead speed of 0.5 mm/min. Statistical Analysis Used: Statistical analysis included One-way ANOVA, followed by the Scheffe post-hoc test with P < 0.05. Results: All dentin desensitizers showed significantly different values: Pro-Argin (4.10 Megapascals [Mpa] < CPP-ACP (4.01 mpa < GLU based primer (3.87 Mpa < Virgin dentin (3.65 Mpa < LASER (3.37 Mpa. Conclusions : On comparing the effect of prepared virgin dentin, GLU based primer, CPP-ACP, LASER and Pro-Argin on the retention of complete cast metal crowns luted with glass ionomer cement on prepared teeth, it can be concluded that Pro-Argin and CPP-ACP showed the best retention in this in vitro study.

  7. Genotoxicity of corrosion eluates obtained from orthodontic brackets in vitro.

    Science.gov (United States)

    Angelieri, Fernanda; Marcondes, Joao Paulo C; de Almeida, Danielle Cristina; Salvadori, Daisy M F; Ribeiro, Daniel A

    2011-04-01

    The purpose of this study was to evaluate whether corrosion eluates obtained from commercially available orthodontic brackets are able to induce genetic damage in vitro. Genotoxicity was assessed by the single cell gel (comet) assay using Chinese hamster ovary (CHO) cells. The following orthodontic metallic brackets were used: Morelli (Sorocaba, Brazil); Abzil (São José do Rio Preto, Brazil); Dentaurum (Pforzheim, Germany); and 3M Unitek (Puchheim, Germany). Each dental bracket was submitted to a corrosion process in a solution containing equal amounts of acetic acid and sodium chloride at 0.1 M concentration for 1, 3, 7, 14, 21, 35, and 70 days. CHO cells were exposed to eluates for 30 minutes at 37°C. The negative control was treated with the same solution used for corrosion process for 30 minutes at 37°C. Independent positive control was performed with methyl methanesulfonate (MMS) (Sigma Aldrich, St. Louis, Mo) at 1 ug/mL for 1 hour. None of the eluates was found to exhibit genotoxicity, regardless of the different commercial brands of orthodontic appliance used. In summary, our results indicate corrosion eluates obtained from orthodontic brackets do not induce genetic damage as assessed by single cell gel (comet) assay. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  8. Doxycycline desensitization in chronic Q fever—A critical tool for the clinician

    Directory of Open Access Journals (Sweden)

    Aila Luise Caplunik-Pratsch

    2018-01-01

    Full Text Available We present the case of a 45 year old woman with acute Q fever pneumonia who progressed to the chronic phase of the disease despite azithromycin therapy. A trial of doxycycline was halted because of severe allergy and she was put on clarithromycin and later moxifloxacin. Failure of both drugs required desensitization to doxycycline with escalating doses. After two-year treatment with doxycycline-hydroxychloroquine combination, complete recovery was declared. Our case highlights the option of doxycycline desensitization when an acute allergic reaction poses an obstacle to optimal treatment.

  9. Antibacterial Activity of Orthodontic Cement Containing Quaternary Ammonium Polyethylenimine Nanoparticles Adjacent to Orthodontic Brackets.

    Science.gov (United States)

    Sharon, Eldad; Sharabi, Revital; Eden, Adi; Zabrovsky, Asher; Ben-Gal, Gilad; Sharon, Esi; Pietrokovski, Yoav; Houri-Haddad, Yael; Beyth, Nurit

    2018-03-27

    Enamel demineralization is a common problem found in patients using orthodontic devices, such as orthodontic braces. It was found that Streptoccocus mutans growth increases adjacent to orthodontic devices, which may result in caries development. Incorporated antibacterial quaternary ammonium polyethylenimine (QPEI) nanoparticles were previously shown to be highly efficacious against various bacteria. Combining antibacterial materials in orthodontic cement may be advantageous to prevent bacterial outgrowth adjacent to orthodontic brackets. The aim was to evaluate the efficiency of orthodontic cement containing QPEI nanoparticles in reducing S. mutans and Lactobacillus casei outgrowth adjacent to orthodontic brackets. Orthodontic brackets were bonded to the buccal surfaces of extracted lower incisors. The antibacterial effect on S. mutans and L. casei outgrowth of Neobond bracket adhesive orthodontic cement with and without QPEI nanoparticles was compared. The antibacterial effect was evaluated using crystal violet staining and bacterial count (CFU/mL). The teeth in the experimental group, with the QPEI nanoparticles cement, showed significantly lower optical density (OD) values and CFU counts of S. mutans and L. casei than the teeth in the control group ( p brackets.

  10. Cytotoxic effects of polycarbonate-based orthodontic brackets by activation of mitochondrial apoptotic mechanisms

    NARCIS (Netherlands)

    Kloukos, D.; Taoufik, E.; Eliades, T.; Katsaros, C.; Eliades, G.

    2013-01-01

    OBJECTIVES: The aim of the study was to evaluate the biological effects of water eluents from polycarbonate based esthetic orthodontic brackets. METHODS: The composite polycarbonate brackets tested were Silkon Plus (SL, fiber-glass-reinforced), Elan ME (EL, ceramic particle-reinforced) and Elegance

  11. Rapid desensitization induces internalization of antigen-specific IgE on mouse mast cells.

    Science.gov (United States)

    Oka, Tatsuya; Rios, Eon J; Tsai, Mindy; Kalesnikoff, Janet; Galli, Stephen J

    2013-10-01

    Rapid desensitization transiently prevents severe allergic reactions, allowing administration of life-saving therapies in previously sensitized patients. However, the mechanisms underlying successful rapid desensitization are not fully understood. We sought to investigate whether the mast cell (MC) is an important target of rapid desensitization in mice sensitized to exhibit IgE-dependent passive systemic anaphylaxis in vivo and to investigate the antigen specificity and underlying mechanisms of rapid desensitization in our mouse model. C57BL/6 mice (in vivo) or primary isolated C57BL/6 mouse peritoneal mast cells (PMCs; in vitro) were passively sensitized with antigen-specific anti-2,4-dinitrophenyl IgE, anti-ovalbumin IgE, or both. MCs were exposed over a short period of time to increasing amounts of antigen (2,4-dinitrophenyl-human serum albumin or ovalbumin) in the presence of extracellular calcium in vitro or by means of intravenous administration to sensitized mice in vivo before challenging the mice with or exposing the PMCs to optimal amounts of specific or irrelevant antigen. Rapidly exposing mice or PMCs to progressively increasing amounts of specific antigen inhibited the development of antigen-induced hypothermia in sensitized mice in vivo and inhibited antigen-induced PMC degranulation and prostaglandin D2 synthesis in vitro. Such MC hyporesponsiveness was induced antigen-specifically and was associated with a significant reduction in antigen-specific IgE levels on MC surfaces. Rapidly exposing MCs to progressively increasing amounts of antigen can both enhance the internalization of antigen-specific IgE on the MC surface and also desensitize these cells in an antigen-specific manner in vivo and in vitro. Copyright © 2013 American Academy of Allergy, Asthma & Immunology. Published by Mosby, Inc. All rights reserved.

  12. Frequency and severity of reactions to a 325-mg aspirin dose during desensitization.

    Science.gov (United States)

    Schuler, Charles F; Baldwin, James L; Baptist, Alan P

    2017-03-01

    The frequency with which patients with aspirin-exacerbated respiratory disease (AERD) react to 325 mg of aspirin during aspirin desensitization, or fail to react at all, is not fully known. To determine the rate and type of reaction at 325 mg of aspirin during desensitization. A retrospective study of 104 patients who underwent aspirin desensitization from 2010 to 2016 was performed. A standard desensitization protocol (starting at 20-40 mg, progressing through 325 mg, and extinguishing reactions by dose repetition) was used. Reactions were defined by upper respiratory tract symptoms, lower respiratory tract symptoms, and/or forced expiratory volume in 1 second decrease of 15% or greater. Patients who did and did not react were compared by logistic regression. Eighty-four patients reacted (81%) and 20 did not (19%). Seventy-seven patients who had a provoking reaction at 162 mg of aspirin or less subsequently extinguished their reactions before they reached a dose of 325 mg and had no problems at that dose; one subsequent 325-mg reaction occurred during a protocol violation. One initial provoking reaction to 325 mg occurred. Both 325-mg reactions were mild, and neither met the forced expiratory volume in 1 second criterion for a clinically meaningful change. The remaining 5 patients could not complete the protocol because of persistent reactions or social reasons. Reactors were more likely to have had asthma for more than 10 years than nonreactors (odds ratio, 3.2; 95% confidence interval, 1.0-10.3; P = .05). During aspirin desensitization for AERD, provoking reactions at the 325-mg dose are rare (1%) and mild. Patients who react at 162 mg or less and extinguish their reactions may be able to administer the 325-mg dose at home. Copyright © 2016 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  13. Evaluation of Micro-organism in Ligated Metal and Self-ligating Brackets using Scanning Electron Microscopy: An In Vivo Study.

    Science.gov (United States)

    Sunil, P C; Michael, Tony; Raju, Aravind S; Paul, Renji K; Mamatha, J; Ebin, T M

    2015-07-01

    The objective of the study was to determine the sites of plaque accumulation and to compare the plaque accumulated with metal and self-ligating orthodontic brackets in order to know which bracket type had a higher plaque retaining capacity. The study was done on 20 subjects who were scheduled for orthodontic treatment including extraction of four premolars and fixed orthodontic appliances. Mesh-backed edgewise metal brackets ligated with steel ligatures and self-ligating brackets were bonded to the premolars to be extracted using composite (Transbond XT, 3M). The subjects were told to continue their normal oral hygiene regimen. Teeth were extracted at 1, 2, and 3 weeks after bracket bonding. Plaque attached to the buccal surfaces was stained using plaque disclosing agent. The teeth were then immersed in fixative containing 4% formaldehyde and 1% glutaraldehyde in phosphate buffer for 24 h, followed by 0.1 M phosphate buffer for 12 h. The specimens were then mounted on aluminum stubs, and sputter coated with gold prior to Scanning electron microscopy examination. The results showed that increased retention of plaque in metal brackets ligated with steel ligatures and comparatively less in self-ligating brackets at the base of the brackets. This study highlights that higher retention of plaque in metal brackets ligated with steel ligatures and comparatively less plaque retention in self-ligating brackets. Excess composite around the bracket base is the critical site of plaque accumulation associated with fixed appliances due to its rough surface texture.

  14. Comparison of frictional resistance between self-ligating and conventional brackets tied with elastomeric and metal ligature in orthodontic archwires.

    Science.gov (United States)

    Leite, Vanessa Vieira; Lopes, Murilo Baena; Gonini Júnior, Alcides; Almeida, Marcio Rodrigues de; Moura, Sandra Kiss; Almeida, Renato Rodrigues de

    2014-01-01

    To compare the frictional resistance between self-ligating and conventional brackets tied to different types of wire. Abzil Kirium Capelozza (Pattern I) and Easy Clip (Roth prescription) incisor brackets were used. An elastomeric ligature or a 0.10-in ligating wire was used to ligate the wire to the Abzil bracket. Three types of orthodontic archwire alloys were assessed: 0.016-in NiTi wire, 0.016 x 0.021-in NiTi wire and 0.019 x 0.025-in steel wire. Ten observations were carried out for each bracket-archwire angulation combination. Brackets were mounted in a special appliance, positioned at 90 degrees in relation to the wire and tested in two angulations. Frictional test was performed in a Universal Testing Machine at 5 mm/min and 10 mm of displacement. The means (MPa) were submitted to ANOVA and Tukey's test set at 5% of significance. The surfaces of wires and brackets were observed at SEM. Steel-tied brackets (16.48 ± 8.31) showed higher means of frictional resistance than elastomeric-tied brackets (4.29 ± 2.16 ) and self-ligating brackets (1.66 ± 1.57) (P 0.05). No statistical differences (P > 0.05) were found between zero (7.76 ± 8.46) and five-degree (7.19 ± 7.93) angulations. Friction was influenced not only by the type of bracket, but also by the ligating systems. Different morphological aspects were observed for the brackets and wires studied.

  15. Bacterial adhesion on conventional and self-ligating metallic brackets after surface treatment with plasma-polymerized hexamethyldisiloxane.

    Science.gov (United States)

    Tupinambá, Rogerio Amaral; Claro, Cristiane Aparecida de Assis; Pereira, Cristiane Aparecida; Nobrega, Celestino José Prudente; Claro, Ana Paula Rosifini Alves

    2017-01-01

    Plasma-polymerized film deposition was created to modify metallic orthodontic brackets surface properties in order to inhibit bacterial adhesion. Hexamethyldisiloxane (HMDSO) polymer films were deposited on conventional (n = 10) and self-ligating (n = 10) stainless steel orthodontic brackets using the Plasma-Enhanced Chemical Vapor Deposition (PECVD) radio frequency technique. The samples were divided into two groups according to the kind of bracket and two subgroups after surface treatment. Scanning Electron Microscopy (SEM) analysis was performed to assess the presence of bacterial adhesion over samples surfaces (slot and wings region) and film layer integrity. Surface roughness was assessed by Confocal Interferometry (CI) and surface wettability, by goniometry. For bacterial adhesion analysis, samples were exposed for 72 hours to a Streptococcus mutans solution for biofilm formation. The values obtained for surface roughness were analyzed using the Mann-Whitney test while biofilm adhesion were assessed by Kruskal-Wallis and SNK test. Significant statistical differences (pbrackets after surface treatment and between conventional and self-ligating brackets; no significant statistical differences were observed between self-ligating groups (p> 0.05). Plasma-polymerized film deposition was only effective on reducing surface roughness and bacterial adhesion in conventional brackets. It was also noted that conventional brackets showed lower biofilm adhesion than self-ligating brackets despite the absence of film.

  16. The experiment progress of bracket brazing to SSMIC for the ITER ELM prototype coil

    International Nuclear Information System (INIS)

    Shi, Yi; Wu, Yu; Jin, Huan; Ren, Zhibin; Han, Houxiang; Qian, Jing; Qian, Li; Liu, Bo

    2014-01-01

    Highlights: • In this study, the experimental research of brackets brazing to stainless steel jacketed, Mineral Insulated Conductor (SSMIC) of the first Edge Localized Modes (ELMs) prototype coil for ITER has been made. • The technology for controlling the fluidity of silver-based brazing alloy is developed to meet the bracket brazing. • Brazing experiments to find the reason for cracks are carried out and the improved brazing technologies to restrain the cracks in the Inconel 625 jacket with silver-based alloy are developed. - Abstract: The first Edge Localized Modes (ELMs) prototype coil for International Thermonuclear Experimental Reactor (ITER) has been manufactured in the Institute of Plasma Physics, CAS (ASIPP) at 2014. The all 19 brackets need to braze to the stainless steel jacketed, Mineral Insulated Conductor (SSMIC) for transporting the nuclear heating in the brackets to the water-cooled SSMIC. Silver-based alloy is the only candidate brazing filler for the bracket brazing due to the limitation from melting point temperature and strength. In this paper, firstly, the experimental study for controlling the fluidity of silver-based brazing alloy is developed. And then, the brazing experiment of prototype bracket is introduced to develop the brazing process and some cracks in the Inconel 625 jackets surface appeared unexpectedly. The microstructures and tensile performance study of the cracked Inconel 625 jacket were made to explore the reason for cracks and the improved brazing technologies to suppress the cracks are developed. Finally, the bracket brazing experiment for the first ELM prototype coil is carried out, In spite of this, some cracks also appear in the Inconel 625 jackets

  17. The experiment progress of bracket brazing to SSMIC for the ITER ELM prototype coil

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Yi, E-mail: shiyi@ipp.ac.cn; Wu, Yu; Jin, Huan; Ren, Zhibin; Han, Houxiang; Qian, Jing; Qian, Li; Liu, Bo

    2014-11-15

    Highlights: • In this study, the experimental research of brackets brazing to stainless steel jacketed, Mineral Insulated Conductor (SSMIC) of the first Edge Localized Modes (ELMs) prototype coil for ITER has been made. • The technology for controlling the fluidity of silver-based brazing alloy is developed to meet the bracket brazing. • Brazing experiments to find the reason for cracks are carried out and the improved brazing technologies to restrain the cracks in the Inconel 625 jacket with silver-based alloy are developed. - Abstract: The first Edge Localized Modes (ELMs) prototype coil for International Thermonuclear Experimental Reactor (ITER) has been manufactured in the Institute of Plasma Physics, CAS (ASIPP) at 2014. The all 19 brackets need to braze to the stainless steel jacketed, Mineral Insulated Conductor (SSMIC) for transporting the nuclear heating in the brackets to the water-cooled SSMIC. Silver-based alloy is the only candidate brazing filler for the bracket brazing due to the limitation from melting point temperature and strength. In this paper, firstly, the experimental study for controlling the fluidity of silver-based brazing alloy is developed. And then, the brazing experiment of prototype bracket is introduced to develop the brazing process and some cracks in the Inconel 625 jackets surface appeared unexpectedly. The microstructures and tensile performance study of the cracked Inconel 625 jacket were made to explore the reason for cracks and the improved brazing technologies to suppress the cracks are developed. Finally, the bracket brazing experiment for the first ELM prototype coil is carried out, In spite of this, some cracks also appear in the Inconel 625 jackets.

  18. Sensory Desensitization Training for Successful Net Application and EEG/ERP Acquisition in Difficult to Test Children

    Science.gov (United States)

    Roesler, Cynthia P.; Flax, Judy; MacRoy-Higgins, Michelle; Fermano, Zena; Morgan-Byrne, Julie; Benasich, April A.

    2013-01-01

    This study examined the effectiveness of sensory desensitization training for 12 nonverbal children with autism to facilitate participation in an electrophysiological study assessing linguistic processing. Sensory desensitization was achieved for 10 of the 12 children and thus allowed collection of usable data in a passive linguistic paradigm.…

  19. Effects Of Desensitization Treatment On Core-Condition Training

    Science.gov (United States)

    Fry, P. S.

    1973-01-01

    Pre- and posttest ratings on measures of helping skills such as empathy, respect, concreteness, and genuineness were obtained in the preliminary and advanced training. A significant training effect was obtained for both groups. Desensitization treatment was a significant source of variance for the experimental subjects in training. (Author/LA)

  20. Comparison of Galvanic Currents Generated Between Different Combinations of Orthodontic Brackets and Archwires Using Potentiostat: An In Vitro Study.

    Science.gov (United States)

    Nayak, Rabindra S; Shafiuddin, Bareera; Pasha, Azam; Vinay, K; Narayan, Anjali; Shetty, Smitha V

    2015-07-01

    Technological advances in wire selection and bracket design have led to improved treatment efficiency and allowed longer time intervals between appliance adjustments. The wires remain in the mouth for a longer duration and are subjected to electrochemical reactions, mechanical forces of mastication and generalized wear. These cause different types of corrosion. This study was done to compare the galvanic currents generated between different combinations of brackets and archwires commonly used in orthodontic practices. The materials used for the study included different commercially available orthodontic archwires and brackets. The galvanic current generated by individual materials and different combinations of these materials was tested and compared. The orthodontic archwires used were 0.019″ × 0.025″ heat-activated nickel-titanium (3M Unitek), 0.019″ × 0.025″ beta-titanium (3M Unitek) and 0.019″ × 0.025″ stainless steel (3M Unitek). The orthodontic brackets used were 0.022″ MBT laser-cut (Victory Series, 3M Unitek) and metal-injection molded (Leone Company) maxillary central incisor brackets respectively. The ligature wire used for ligation was 0.009″ stainless steel ligature (HP Company). The galvanic current for individual archwires, brackets, and the different bracket-archwire-ligature combinations was measured by using a Potentiostat machine. The data were generated using the Linear Sweep Voltammetry and OriginPro 8.5 Graphing and Data Analysis Softwares. The study was conducted in two phases. Phase I comprised of five groups for open circuit potential (OCP) and galvanic current (I), whereas Phase II comprised of six groups for galvanic current alone. Mean, standard deviation and range were computed for the OCP and galvanic current (I) values obtained. Results were subjected to statistical analysis through ANOVA. In Phase I, higher mean OCP was recorded in stainless steel archwire, followed by beta-titanium archwire, heat-activated nickel

  1. The use of easily debondable orthodontic adhesives with ceramic brackets.

    Science.gov (United States)

    Ryu, Chiyako; Namura, Yasuhiro; Tsuruoka, Takashi; Hama, Tomohiko; Kaji, Kaori; Shimizu, Noriyoshi

    2011-01-01

    We experimentally produced an easily debondable orthodontic adhesive (EDA) containing heat-expandable microcapsules. The purpose of this in vitro study was to evaluate the best debondable condition when EDA was used for ceramic brackets. Shear bond strengths were measured before and after heating and were compared statistically. Temperatures of the bracket base and pulp wall were also examined during heating. Bond strengths of EDA containing 30 wt% and 40 wt% heat-expandable microcapsules were 13.4 and 12.9 MPa, respectively and decreased significantly to 3.8 and 3.7 MPa, respectively, after heating. The temperature of the pulp wall increased 1.8-3.6°C after heating, less than that required to induce pulp damage. Based on the results, we conclude that heating for 8 s during debonding of ceramic brackets bonded using EDA containing 40 wt% heat-expandable microcapsules is the most effective and safest method for the enamel and pulp.

  2. Bracketed morality revisited: how do athletes behave in two contexts?

    Science.gov (United States)

    Kavussanu, Maria; Boardley, Ian D; Sagar, Sam S; Ring, Christopher

    2013-10-01

    The concept of bracketed morality has received empirical support in several sport studies (e.g., Bredemeier & Shields, 1986a, 1986b). However, these studies have focused on moral reasoning. In this research, we examined bracketed morality with respect to moral behavior in sport and university contexts, in two studies. Male and female participants (Study 1: N = 331; Study 2: N = 372) completed questionnaires assessing prosocial and antisocial behavior toward teammates and opponents in sport and toward other students at university. Study 2 participants also completed measures of moral disengagement and goal orientation in both contexts. In most cases, behavior in sport was highly correlated with behavior at university. In addition, participants reported higher prosocial behavior toward teammates and higher antisocial behavior toward opponents in sport than toward other students at university. The effects of context on antisocial behavior were partially mediated by moral disengagement and ego orientation. Our findings extend the bracketed morality concept to prosocial and antisocial behavior.

  3. In vitro assessment of photocatalytic titanium oxide surface modified stainless steel orthodontic brackets for antiadherent and antibacterial properties against Lactobacillus acidophilus.

    Science.gov (United States)

    Shah, Alok Girish; Shetty, Pradeep Chandra; Ramachandra, C S; Bhat, N Sham; Laxmikanth, S M

    2011-11-01

    To assess the antiadherent and antibacterial properties of surface modified stainless steel orthodontic brackets with photocatalytic titanium oxide (TiO(2)) against Lactobacillus acidophilus. This study was done on 120 specimens of stainless steel preadjusted edgewise appliance (PEA) orthodontic brackets. The specimens were divided into four test groups. Each group consisted of 30 specimens. Groups containing uncoated brackets acted as a control group for their respective experimental group containing coated brackets. Surface modification of brackets was carried out by the radiofrequency (RF) magnetron sputtering method with photocatalytic TiO(2). Brackets then were subjected to microbiological tests for assessment of the antiadherent and antibacterial properties of photocatalytic TiO(2) coating against L acidophilus. Orthodontic brackets coated with photocatalytic TiO(2) showed an antiadherent effect against L acidophilus compared with uncoated brackets. The bacterial mass that was bound to the TiO(2)-coated brackets was less when compared with the uncoated brackets. Furthermore, TiO(2)-coated brackets had a bactericidal effect on L acidophilus, which causes dental caries. Surface modification of orthodontic brackets with photocatalytic TiO(2) can be used to prevent the accumulation of dental plaque and the development of dental caries during orthodontic treatment.

  4. Orthodontic brackets in high field MR imaging: experimental evaluation of magnetic field interactions at 3.0 tesla; Kieferorthopaedische Brackets in der Hochfeld-Magnetresonanz-Tomographie: Experimentelle Beurteilung magnetischer Anziehungs- und Rotationskraefte bei 3 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Kemper, J.; Adam, G. [Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie, Universitaetsklinikum Eppendorf, Hamburg (Germany); Klocke, A.; Kahl-Nieke, B. [Poliklinik fuer Kieferorthopaedie, Universitaetsklinikum Eppendorf, Hamburg (Germany)

    2005-12-15

    Purpose: To evaluate static magnetic field interactions for 32 commonly used orthodontic brackets in a 3.0 T magnetic resonance imaging (MRI) system. Materials and methods: 32 orthodontic brackets consisting of a steel alloy (n=27), a cobalt-chromium alloy (n=2), ceramic (n=1), ceramic with a steel slot (n=1), and titanium (n=1) from 13 different manufacturers were tested for magnetic field interactions in a static magnetic field at 3.0 T (Gyroscan Intera 3.0 T, Philips Medical Systems, Best, Netherlands). The magnetic deflection force F{sub Z} [mN] was evaluated by determining the deflection angle {beta}[ ] using the established deflection angle test according to the ASTM guidelines. The magnetic-field-induced rotational force F{sub rot} or torque was qualitatively determined using a 5-point grading scale (0: no torque; +4: very strong torque). Results: In 18 of the 32 brackets, the deflection angle {beta} was found to be > 45 and the translational force exceeded the gravitational force F{sub G} on the particular bracket (F{sub Z}: 1.2-45.7 mN). The translational force F{sub Z} was found to be up to 68.5 times greater than the gravitational force F{sub G} (F{sub Z}/F{sub G}: 1.4-68.5). The rotational force F{sub rot} was correspondingly high (+3/+4) for those brackets. For the remaining 14 objects, the deflection angles were < 45 and the torque measurements ranged from 0 to +2. The static magnetic field did not affect the titanium bracket and the ceramic bracket. No measurable translational and rotational forces were found. (orig.)

  5. Influence of bracket-slot design on the forces released by superelastic nickel-titanium alignment wires in different deflection configurations.

    Science.gov (United States)

    Nucera, Riccardo; Gatto, Elda; Borsellino, Chiara; Aceto, Pasquale; Fabiano, Francesca; Matarese, Giovanni; Perillo, Letizia; Cordasco, Giancarlo

    2014-05-01

    To evaluate how different bracket-slot design characteristics affect the forces released by superelastic nickel-titanium (NiTi) alignment wires at different amounts of wire deflection. A three-bracket bending and a classic-three point bending testing apparatus were used to investigate the load-deflection properties of one superelastic 0.014-inch NiTi alignment wire in different experimental conditions. The selected NiTi archwire was tested in association with three bracket systems: (1) conventional twin brackets with a 0.018-inch slot, (2) a self-ligating bracket with a 0.018-inch slot, and (3) a self-ligating bracket with a 0.022-inch slot. Wire specimens were deflected at 2 mm and 4 mm. Use of a 0.018-inch slot bracket system, in comparison with use of a 0.022-inch system, increases the force exerted by the superelastic NiTi wires at a 2-mm deflection. Use of a self-ligating bracket system increases the force released by NiTi wires in comparison with the conventional ligated bracket system. NiTi wires deflected to a different maximum deflection (2 mm and 4 mm) release different forces at the same unloading data point (1.5 mm). Bracket design, type of experimental test, and amount of wire deflection significantly affected the amount of forces released by superelastic NiTi wires (Pwire's load during alignment.

  6. Suitability of orthodontic brackets for rebonding and reworking following removal by air pressure pulses and conventional debracketing techniques.

    Science.gov (United States)

    Knösel, Michael; Mattysek, Simone; Jung, Klaus; Kubein-Meesenburg, Dietmar; Sadat-Khonsari, Reza; Ziebolz, Dirk

    2010-07-01

    To test the null hypothesis that there are no significant differences in the reusability of debonded brackets with regard to debonding technique and adhesive used. Ninety-six osteotomed third molars were randomly assigned to two study groups (n = 48) for bonding of a 0.018-inch bracket (Ormesh, Ormco) with either a composite adhesive (Mono-Lok2; RMO) or a glass ionomer cement (GIC; Fuji Ortho LC;GC). Each of these two groups were then randomly divided into four subgroups (n = 12) according to the method of debonding using (1) bracket removal pliers (BRP; Dentaurum), (2) a side cutter (SC; Dentaurum), (3) a lift-off debracketing instrument (LODI; 3M-Unitek), or (4) an air pressure pulse device (CoronaFlex; KaVo). The brackets were subsequently assessed visually for reusability and reworkability with 2x magnification and by pull testing with a 0.017- x 0.025-inch steel archwire. The proportions of reusable brackets were individually compared in terms of mode of removal and with regard to adhesives using the Fisher exact test (alpha = 5%). The null hypothesis was rejected. Not taking into account the debonding method, brackets bonded with GIC were judged to a significant extent (81%; n = 39; P < .01) to be reworkable compared with those bonded with composite (56%; n = 27). All brackets in both adhesive groups removed with either the LODI or the CoronaFlex were found to be reusable, whereas 79% (46%) of the brackets removed with the BRP (SC) were not. The proportion of reusable brackets differed significantly between modes of removal (P < .01). With regard to bracket reusability, the SC and the BRP cannot be recommended for debonding brackets, especially in combination with a composite adhesive.

  7. Shear Bond Strength of DentStat(trademark) for Bracket Bonding to Gold, Ceramic, and Enamel

    Science.gov (United States)

    2012-12-21

    they make a good choice for orthodontic bracket retention. According to a Cochrane review by Mandall (Mandall et al, 2002) all of their review...was developed as a temporary material for use in military field environments, can be used to effectively bond orthodontic brackets to type III gold... orthodontic composite resin adhesive, Transbond XTTM (3M Unitek Monrovia, California), as they are used to bond orthodontic brackets to gold

  8. Root resorption during orthodontic treatment with self-ligating or conventional brackets: a systematic review and meta-analysis.

    Science.gov (United States)

    Yi, Jianru; Li, Meile; Li, Yu; Li, Xiaobing; Zhao, Zhihe

    2016-11-21

    The aim of this study was to compare the external apical root resorption (EARR) in patients receiving fixed orthodontic treatment with self-ligating or conventional brackets. Studies comparing the EARR between orthodontic patients using self-ligating or conventional brackets were identified through electronic search in databases including CENTRAL, PubMed, EMBASE, China National Knowledge Infrastructure (CNKI) and SIGLE, and manual search in relevant journals and reference lists of the included studies until Apr 2016. The extraction of data and risk of bias evaluation were conducted by two investigators independently. The original outcome underwent statistical pooling by using Review Manager 5. Seven studies were included in the systematic review, out of which, five studies were statistically pooled in meta-analysis. The value of EARR of maxillary central incisors in the self-ligating bracket group was significantly lower than that in the conventional bracket group (SMD -0.31; 95% CI: -0.60--0.01). No significant differences in other incisors were observed between self-ligating and conventional brackets. Current evidences suggest self-ligating brackets do not outperform conventional brackets in reducing the EARR in maxillary lateral incisors, mandible central incisors and mandible lateral incisors. However, self-ligating brackets appear to have an advantage in protecting maxillary central incisor from EARR, which still needs to be confirmed by more high-quality studies.

  9. Biomechanical characteristics of self-ligating brackets in a vertically displaced canine model: a finite element analysis.

    Science.gov (United States)

    Kim, S-J; Kwon, Y-H; Hwang, C-J

    2016-05-01

    The objective of this study was to compare the biomechanical characteristics between two types of self-ligating brackets and conventional metal brackets using finite element analysis of a vertically displaced canine model focusing on the desired force on the canine and undesirable forces on adjacent teeth. Three-dimensional finite element models of the maxillary dentition with 1-mm, 2-mm, and 3-mm vertically displaced canines were constructed. Two different self-ligating brackets (In-Ovation C and Smart clip) and a conventional metal bracket (Micro-arch) were modeled. After a 0.016-inch NiTi (0.40 mm, round) wire was engaged, the displacement of each tooth was calculated using x-, y-, and z-coordinates, and the tensile and compressive stresses were calculated. The extrusion and maximal tensile stress of the canine differed little between the three brackets, but the intrusion and minimal compressive stress values of the adjacent teeth differed considerably and were highest in the Smart clip and least in the In-Ovation C. The extrusion and maximal tensile stress of the canine in the 3-mm displacement model was less than that in the 2-mm displacement model, and the intrusion and minimal compressive stress of the adjacent teeth increased with the degree of displacement. Self-ligating brackets were not superior to conventional brackets in leveling a vertically displaced canine. A continuous arch wire may not be recommended for leveling of severely displaced canines whether using self-ligating or conventional brackets. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Effects of agonist efficacy on desensitization of phosphoinositide hydrolysis mediated by m1 and m3 muscarinic receptors expressed in Chinese hamster ovary cells

    International Nuclear Information System (INIS)

    Hu, J.; Wang, S.Z.; el-Fakahany, E.E.

    1991-01-01

    Muscarinic receptor agonist-induced desensitization of phosphoinositide (PI) hydrolysis and loss of receptors were studied in Chinese hamster ovary (CHO) cells transfected with the m1 and m3 muscarinic receptor genes. Long-term exposure to the full agonist carbamylcholine (CBC) resulted in a time-dependent attenuation of the maximal PI response and a decrease in agonist potency. This desensitization was accompanied by a parallel loss of maximal ligand binding without an alteration of the binding affinity. The time course of both receptor desensitization and down-regulation was similar in m1 and m3 CHO cells. The PI response to the partial agonist McN-A-343 (McN) in m1 cells was more sensitive to desensitization by CBC than the response to the latter agonist, and this desensitization was faster than receptor down-regulation. Desensitization of the PI response to McN was reflected as a decrease in the maximal response without a marked change in potency. McN induced slow desensitization of the PI response to CBC but a much faster desensitization of its own response. Our data provide evidence that although muscarinic agonist-induced desensitization of PI hydrolysis in CHO cells is due mainly to loss of receptors, there are other important factors which play a role in this process, e.g., receptor-effector uncoupling. The relative contribution of these different mechanisms depends on the efficacy of the agonists used for the receptor desensitization and activation steps

  11. The Process of Fear Reduction Through Systematic Desensitization

    Science.gov (United States)

    Schroeder, Harold E.; Rich, Alex R.

    1976-01-01

    This study investigated the process of fear change during a course of systematic desensitization therapy. Behavioral, subjective, and physiological measures of fear were taken following each of eight therapy sessions. Changes in one fear system did not appear to be primary in initiating changes in the other fear systems. (Author)

  12. Effects of a Dicalcium and Tetracalcium Phosphate-Based Desensitizer on In Vitro Dentin Permeability.

    Directory of Open Access Journals (Sweden)

    Jianfeng Zhou

    Full Text Available The present study evaluated the effectiveness of a dicalcium and tetracalcium phosphate-based desensitizer in reducing dentin permeability in vitro. Dentin fluid flow was measured before and after treatment of dentin with patent dentinal tubules using 1 or 3 applications of the dicalcium and tetracalcium phosphate containing agent TeethmateTM (TM and comparing the results with two sodium fluoride varnishes VellaTM (VLA and VanishTM (VAN, after storage in artificial saliva for 24 h, 48 h and 7 days. Significant differences were observed among the 4 methods employed for reducing dentin permeability (p < 0.001 and the 3 post-treatment times (p < 0.001. VLA and VAN never achieved 50% permeability reductions consistently in any of the 3 time periods. Only the calcium phosphate-based desensitizer applied for 3 times consistently reduced dentin permeability by 50% after 24 h. When applied once, the permeability reduction of TM increased progressively over the 3 time periods. After 7 days, only one and three applications of the calcium phosphate-based desensitizer consistently reduced dentin permeability by more than 50%. Permeability reductions corresponded well with scanning electron microscopy examination of dentinal tubule orifice occlusion in dentin specimens treated with the agents. Overall, the dicalcium and tetracalcium phosphate-based desensitizer is effective in reducing dentin permeability via a tubule occlusion mechanism. The ability of the agent to reduce dentin permeability renders it to be potentially useful as a clinical dentin desensitizing agent, which has to be confirmed in future clinical studies. By contrast, the two sodium fluoride varnishes are not effective in dentin permeability reduction and should be considered as topical fluoride delivering agents rather than tubular orifice-blocking agents.

  13. Analysis on the precision of the dimensions of self-ligating brackets.

    Science.gov (United States)

    Erduran, Rackel Hatice Milhomens Gualberto; Maeda, Fernando Akio; Ortiz, Sandra Regina Mota; Triviño, Tarcila; Fuziy, Acácio; Carvalho, Paulo Eduardo Guedes

    2016-12-01

    The present study aimed to evaluate the precision of the torque applied by 0.022" self-ligating brackets of different brands, the precision of parallelism between the inner walls of their slots, and precision of their slot height. Eighty brackets for upper central incisors of eight trademarked models were selected: Abzil, GAC, American Orthodontics, Morelli, Orthometric, Ormco, Forestadent, and Ortho Organizers. Images of the brackets were obtained using a scanning electron microscope (SEM) and these were measured using the AutoCAD 2011 software. The tolerance parameters stated in the ISO 27020 standard were used as references. The results showed that only the Orthometric, Morelli, and Ormco groups showed results inconsistent with the ISO standard. Regarding the parallelism of the internal walls of the slots, most of the models studied had results in line with the ISO prescription, except the Morelli group. In assessing bracket slot height, only the Forestadent, GAC, American Orthodontics, and Ormco groups presented results in accordance with the ISO standard. The GAC, Forestadent, and American Orthodontics groups did not differ in relation to the three factors of the ISO 27020 standard. Great variability of results is observed in relation to all the variables. © 2016 Wiley Periodicals, Inc.

  14. Different effects of pentobarbital on two γ-aminobutyrate receptors from rat brain: channel opening, desensitization, and an additional conformational change

    International Nuclear Information System (INIS)

    Cash, D.J.; Subbarao, K.

    1988-01-01

    The effect of pentobarbital on the responses of the γ-aminobutyric acid (GABA) receptor from rat brain was studied in quantitative measurements of GABA-mediated chloride-exchange rates (reflecting channel-opening equilibrium) and receptor desensitization rates by using 36 Cl - tracer ion with negative membrane vesicles. Pentobarbital effected the two phases of 36 Cl - influx in different ways, supporting previous evidence that these are mediated by two different receptors. Both the chloride-exchange rate and the desensitization rate of the faster desensitizing receptor were increased by pentobarbital at concentrations above 20 μM by an allosteric effect shifting the response curve to lower GABA concentrations. A similar enhancement of the responses of the slower desensitizing receptor occurred up to 200 μM pentobarbital. Two pentobarbital effector sites were involved in the allosteric mechanism. Above 500 μM pentobarbital, both the initial chloride-exchange rate and the desensitization rate of the slower desensitizing receptor were decreased. This inhibition, which was immediate, occurred with saturating as well as low GABA concentrations and therefore was not attributed to decreased GABA binding but to inhibitory sites for pentobarbital, different from the allosteric activating sites and the GABA binding sites. The chloride ion exchange activity was seen to recover with time, at concentrations above 1000 μM pentobarbital, in a process with a very steep dependence on pentobarbital concentration. This reactivation was attributed to the conversion of an initial form of the receptor to a final form that was less inhibited by pentobarbital. Comparisons of the effects of pentobarbital on desensitization and on high-affinity ligand binding measurements suggest that increased GABA binding at equilibrium reflects an increased conversion to the desensitized state

  15. Evaluation of force released by deflection of orthodontic wires in conventional and self-ligating brackets.

    Science.gov (United States)

    Higa, Rodrigo Hitoshi; Semenara, Nayara Thiago; Henriques, José Fernando Castanha; Janson, Guilherme; Sathler, Renata; Fernandes, Thais Maria Freire

    2016-01-01

    The aim of the study was to evaluate deflection forces of rectangular orthodontic wires in conventional (MorelliTM), active (In-Ovation RTM) and passive (Damon 3MXTM) self-ligating brackets. Two brands of stainless steel and nickel-titanium (NiTi) wires (MorelliTM and GACTM), in addition to OrmcoTM copper-nickel-titanium wires were used. Specimens were assembled in a clinical simulation device especially designed for this study and tested in an Instron universal testing machine. For the testing procedures, an acrylic structure representative of the maxillary right central incisor was lingually moved in activations of 0 to 1 mm, with readings of the force released by deflection in unloading of 0.5, 0.8 and 1 mm at a constant speed of 2 mm/min. Inter-bracket forces with stainless steel, NiTi and CuNiTi were individually compared by two-way ANOVA, followed by Tukey's tests. Results showed that there were lower forces in conventional brackets, followed by active and passive self-ligating brackets. Within the brands, only for NiTi wires, the MorelliTM brand presented higher forces than GACTM wires. Bracket systems provide different degrees of deflection force, with self-ligating brackets showing the highest forces.

  16. Static and kinetic frictional forces of silica-insert ceramic brackets with coated archwires in artificial saliva.

    Science.gov (United States)

    Shahabi, Mostafa; Salari, Soheil; Poosti, Maryam; Abtahi, Mostafa

    2017-01-01

    During sliding mechanics, the frictional force (FF) is an important counterforce to orthodontic tooth movement. The purpose of this in vitro study was to investigate the static and kinetic FFs of S silica-insert ceramic (SIC) brackets with Teflon-coated (TC) and conventional S stainless steel (SS) archwires. The target group of this study included 80 maxillary canine 0.022 inch slot SIC brackets. Forty SS brackets were used as the control. TC and conventional uncoated SS archwires of different dimensions (0.016, 0.018, 0.016 × 0.022, and 0.018 × 0.025 inch) were examined. All tests were carried out under artificial saliva injected condition. Scanning Electron Micrographs were prepared for two samples of coated and uncoated archwires. Analysis of variance and Tukey post hoc tests were used for statistical purposes (level of significance P brackets showed significantly lower levels of FFs than SS brackets. TC archwires had greater frictional values than conventional uncoated ones. They also exhibited an unusual behavior of increasing kinetic FFs with time. Indentation and delamination of coating were obvious under scanning electron microscopy observations. From the standpoint of friction, SIC brackets may serve well, even better than SS brackets, in sliding mechanics. The coating layer of the archwires may delaminate and lost, causing an impediment to tooth movement.

  17. Shear bond strength and enamel fracture behavior of ceramic brackets Fascination® and Fascination®2.

    Science.gov (United States)

    Gittner, Robert; Müller-Hartwich, Ralf; Engel, Sylvia; Jost-Brinkmann, Paul-Georg

    2012-01-01

    The purpose of this study was to compare the shear bond strength and incidence of enamel fractures of the ceramic brackets Fascination® and Fascination®2. A total of 360 teeth (180 first upper bicuspids and 180 lower incisors) were stored in 96% ethanol, while 360 other teeth (180 first upper bicuspids and 180 lower incisors) were stored in 0.1% thymol. All 720 teeth were bonded one-half each with Fascination® and Fascination®2 brackets using three different adhesives and three different light curing units. The teeth were debonded with a debonding-device according to DIN EN ISO 10477 using a universal testing machine with a crosshead speed of 1 mm per minute. The enamel surface was then examined stereomicroscopically (10x and 40x magnification). The non-parametric Mann-Whitney U test was used, since the data were not normally distributed. The Fascination®2 brackets provided significantly lower shear bond strength than Fascination® brackets (p = 0.003). Fascination® brackets demonstrated significantly fewer, smaller enamel fractures than Fascination®2 brackets (p = 0.012). The lower shear bond strength of the Fascination®2 brackets is clinically acceptable, but our study's experimental design did not enable us to prove whether this is clinically associated with a lower risk of enamel fracture.

  18. Distinct structural features of cyclothiazide are responsible for effects on peak current amplitude and desensitization kinetics at iGluR2

    DEFF Research Database (Denmark)

    Hald, Helle; Ahring, Philip Kiær; Timmermann, Daniel Brunicardi

    2009-01-01

    Ionotropic glutamate receptors (iGluRs) mediate fast excitatory neurotransmission. Upon glutamate application, 2-amino-3-(3-hydroxy-5-methyl-4-isoxazolyl)propionic acid receptors undergo rapid and almost complete desensitization that can be attenuated by positive allosteric modulators. The molecu......Ionotropic glutamate receptors (iGluRs) mediate fast excitatory neurotransmission. Upon glutamate application, 2-amino-3-(3-hydroxy-5-methyl-4-isoxazolyl)propionic acid receptors undergo rapid and almost complete desensitization that can be attenuated by positive allosteric modulators......) in micromolar: 10 (CTZ), 26 (NS1493), 43 (NS5206), and 48 (NS5217)]. The four modulators divide into three groups according to efficacy and desensitization kinetics: (1) CTZ increases the peak current efficacy twice as much as the three analogues and nearly completely blocks receptor desensitization; (2) NS5206...... and NS5217 have low efficacy and only attenuate desensitization partially; (3) NS1493 has low efficacy but nearly completely blocks receptor desensitization. A hydrophobic substituent at the 3-position of the 1,1-dioxo-3,4-dihydro-2H-benzo[e][1,2,4]thiadiazine ring system is important for compound...

  19. Shear Bond Strength of Orthodontic Brackets and Disinclusion Buttons: Effect of Water and Saliva Contamination

    OpenAIRE

    Sfondrini, Maria Francesca; Fraticelli, Danilo; Gandini, Paola; Scribante, Andrea

    2013-01-01

    Purpose. The aim of this study was to assess the effect of water and saliva contamination on the shear bond strength and failure site of orthodontic brackets and lingual buttons. Materials and Methods. 120 bovine permanent mandibular incisors were randomly divided into 6 groups of 20 specimens each. Both orthodontic brackets and disinclusion buttons were tested under three different enamel surface conditions: (a) dry, (b) water contamination, and (c) saliva contamination. Brackets and buttons...

  20. Comparison of Cue-Controlled Desensitization, Rational Restructuring, and a Credible Placebo in the Treatment of Speech Anxiety.

    Science.gov (United States)

    Lent, Robert W.; And Others

    1981-01-01

    The efficacy of cue-controlled desensitization and systematic rational restructuring was compared with a placebo method and a waiting-list control in reducing public speaking and nontargeted anxieties. Cue-controlled desensitization was generally more effective than the other groups in reducing subjective speech anxiety. (Author)

  1. Normal forms of dispersive scalar Poisson brackets with two independent variables

    Science.gov (United States)

    Carlet, Guido; Casati, Matteo; Shadrin, Sergey

    2018-03-01

    We classify the dispersive Poisson brackets with one dependent variable and two independent variables, with leading order of hydrodynamic type, up to Miura transformations. We show that, in contrast to the case of a single independent variable for which a well-known triviality result exists, the Miura equivalence classes are parametrised by an infinite number of constants, which we call numerical invariants of the brackets. We obtain explicit formulas for the first few numerical invariants.

  2. Antimicrobial action of chlorhexidine digluconate in self-ligating and conventional metal brackets infected with Streptococcus mutans biofilm

    Directory of Open Access Journals (Sweden)

    Dias AP

    2018-04-01

    Full Text Available Ana Paula Dias, Marco Aurélio Benini Paschoal, Rafael Soares Diniz, Lucas Meneses Lage, Letícia Machado Gonçalves Department of Dentistry, CEUMA University, São Luis, Maranhão, Brazil Objectives: The objectives of this study were to assess the adherence of Streptococcus mutans biofilms grown over conventional ligature (CL or self-ligating (SL metal brackets and their bacterial viability after 0.12% chlorhexidine (CHX digluconate treatment. Materials and methods: The sample consisted of 48 metallic orthodontic brackets divided randomly into two groups: CL (n=24 and SL brackets (n=24. S. mutans biofilms were grown over the bracket surface (96 h and treated with CHX (positive control or 0.9% phosphate-buffered saline (PBS (negative control for 1 min each. Quantitative analysis was assessed by colony-forming units, and fluorescence microscopy was performed aiming to illustrate the outcomes. The tests were done in triplicate at three different times (n=9. Data were analyzed using ANOVA and Tukey test (P<0.05. Results: There were significant differences in brackets’ biofilm formation, being CL largely colonized compared with SL, which was observed by colony-forming unit counting (P<0.05 and microcopy images. Significant reduction in the viability of S. mutans was found in both brackets treated with CHX compared to PBS (P<0.05. Conclusion: The antimicrobial activities of CHX were similar for CL and SL brackets (P>0.05. In conclusion, a lower colonization was achieved in SL brackets and S. mutans biofilms were susceptible to CHX treatment to both studied brackets. Keywords: biofilm, chlorhexidine, orthodontic brackets, Streptococcus mutans

  3. Comparison of Microleakage under Rebonded Stainless Steel Orthodontic Brackets Using Two Methods of Adhesive Removal: Sandblast and Laser.

    Science.gov (United States)

    Tudehzaeim, Mohamad Hossein; Yassaei, Soghra; Taherimoghadam, Shohreh

    2015-02-01

    Debonding is a common occurrence in orthodontic treatment and a considerable number of orthodontists prefer to rebond the detached brackets because of economic issues. The aim of this study was to compare the microleakage beneath rebonded stainless steel brackets using two methods of adhesive removal namely sandblast and laser. Sixty human premolar teeth were randomly divided into three groups. Following bonding the brackets, group 1 served as the control group. Brackets in groups 2 and 3 were debonded, and adhesive removal from the bracket bases was done by means of sandblasting and Er-YAG laser, respectively. After rebonding, teeth in each group were stained with 2% methylene blue for 24 hours, sectioned and examined under a stereomicroscope. Marginal microleakage at the adhesive-enamel and bracket-adhesive interfaces in the occlusal and gingival margins was determined. Statistical analysis was done using the Kruskal-Wallis test. Comparison of the microleakage scores among the three groups revealed no statistically significant difference (P > 0.05). At the enamel-adhesive interface, the gingival margins in all groups showed higher microleakage while in the adhesive-bracket interface, the occlusal margin exhibited greater microleakage. Er-YAG laser irradiation and sandblasting for adhesive removal from the debonded brackets yielded clinically acceptable microleakage scores.

  4. Research and analysis on response characteristics of bracket-line coupling system under wind load

    Science.gov (United States)

    Jiayu, Zhao; Qing, Sun

    2018-01-01

    In this paper, a three-dimensional finite element model of bracket-line coupling system is established based on ANSYS software. Using the wind velocity time series which is generated by MATLAB as a power input, by comparing and analyzing the influence of different wind speeds and different wind attack angles, it is found that when 0 degree wind acts on the structure, wires have a certain damping effect in the bracket-line coupling system and at the same wind speed, the 90 degree direction is the most unfavorable wind direction for the whole structure according to the three kinds of angle wind calculated at present. In the bracket-line coupling system, the bracket structure is more sensitive to the increase of wind speed while the conductors are more sensitive to the change of wind attack angle.

  5. Evaluation of failure characteristics and bond strength after ceramic and polycarbonate bracket debonding : effect of bracket base silanization

    NARCIS (Netherlands)

    Ozcan, M.; Finnema, K.; Ybema, A.

    The objectives of this study were to evaluate the effect of silanization on the failure type and shear-peel bond strength (SBS) of ceramic and polycarbonate brackets, and to determine the type of failure when debonded with either a universal testing machine or orthodontic pliers. Silanized and

  6. Strength Analysis and Process Simulation of Subway Contact Rail Support Bracket of Composite Materials

    Science.gov (United States)

    Fedulov, Boris N.; Safonov, Alexander A.; Sergeichev, Ivan V.; Ushakov, Andrey E.; Klenin, Yuri G.; Makarenko, Irina V.

    2016-10-01

    An application of composites for construction of subway brackets is a very effective approach to extend their lifetime. However, this approach involves the necessity to prevent process-induced distortions of the bracket due to thermal deformation and chemical shrinkage. At present study, a process simulation has been carried out to support the design of the production tooling. The simulation was based on the application of viscoelastic model for the resin. Simulation results were verified by comparison with results of manufacturing experiments. To optimize the bracket structure the strength analysis was carried out as well.

  7. A pilot study of omalizumab to facilitate rapid oral desensitization in high-risk peanut allergic patients

    Science.gov (United States)

    Schneider, Lynda C.; Rachid, Rima; LeBovidge, Jennifer; Blood, Emily; Mittal, Mudita; Umetsu, Dale T.

    2015-01-01

    Background Peanut allergy is a major public health problem that affects 1% of the population and has no effective therapy. Objective To examine the safety and efficacy of oraldesensitization in peanut allergic children in combination with a brief course of anti-IgE monoclonal antibody (omalizumab, Xolair). Methods We performed oral peanut desensitization in peanut allergic children at high risk for developing significant peanut-induced allergic reactions. Omalizumab was administered prior to and during oral peanut desensitization. Results We enrolled 13 children (median age, 10 years), with a median peanut-specific IgE of 229 kUA/L and a median total serum IgE of 621 kU/L, who failed an initial double-blind placebo controlled food challenge at doses 100 mg peanut flour. After pre-treatment with omalizumab, all subjects tolerated the initial 11 desensitization doses given on the first day, including the maximum dose of 500 mg peanut flour (cumulative dose, 992 mg, equivalent to >2 peanuts), requiring minimal or no rescue therapy. 12 subjects then reached the maximum maintenance dose of 4,000 mg peanut flour/day in a median time of 8 weeks, at which point omalizumab was discontinued. All 12 subjects continued on 4,000 mg peanut flour/day and subsequently tolerated a challenge with 8,000 mg peanut flour (equivalent to about 20 peanuts), or 160 to 400 times the dose tolerated before desensitization. During the study, 6 of the 13 subjects experienced mild or no allergic reactions; 6 subjects had Grade 2, and 2 subjects Grade 3 reactions, all of which responded rapidly to treatment. Conclusions Among children with high-risk peanut allergy, treatment with omalizumab may facilitate rapid oral desensitization, and qualitativelyimprove the desensitization process. PMID:24176117

  8. Estudio de brackets autoligables mediante microscopía electrónica de barrido.

    OpenAIRE

    González Ruiz, Aiala

    2015-01-01

    Desde finales del siglo XIX, cuando Angle desarrolló el arco E en su afán de mover los dientes en los tres planos del espacio, se han ido creando diferentes tipos de brackets. Así, a día de hoy tenemos lo que conocemos como brackets preajustados, que llevan la información de 1º, 2º y 3er orden en su estructura interna para evitar las dobleces de los arcos. Sin embargo, el afán de los últimos años ha sido el reducir al mínimo la fricción creada entre bracket y ligadura, y por ello han surgido ...

  9. Analysis of anti-HLA antibodies in sensitized kidney transplant candidates subjected to desensitization with intravenous immunoglobulin and rituximab.

    Science.gov (United States)

    Lobashevsky, Andrew L; Higgins, Nancy G; Rosner, Kevin M; Mujtaba, Muhammad A; Goggins, William C; Taber, Tim E

    2013-07-27

    Preexisting donor-specific antibodies against human leukocyte antigens are major risk factors for acute antibody-mediated and chronic rejection of kidney transplant grafts. Immunomodulation (desensitization) protocols may reduce antibody concentration and improve the success of transplant. We investigated the effect of desensitization with intravenous immunoglobulin and rituximab on the antibody profile in highly sensitized kidney transplant candidates. In 31 transplant candidates (calculated panel-reactive antibody [cPRA], 34%-99%), desensitization included intravenous immunoglobulin on days 0 and 30 and a single dose of rituximab on day 15. Anti-human leukocyte antigen antibodies were analyzed before and after desensitization. Reduction of cPRA from 25% to 50% was noted for anti-class I (5 patients, within 20-60 days) and anti-class II (3 patients, within 10-20 days) antibodies. After initial reduction of cPRA, the cPRA increased within 120 days. In 24 patients, decrease in mean fluorescence intensity of antibodies by more than 50% was noted at follow-up, but there was no reduction of cPRA. Rebound occurred in 65% patients for anti-class I antibodies at 350 days and anti-class II antibodies at 101 to 200 days. Probability of rebound effect was higher in patients with mean fluorescence intensity of more than 10,700 before desensitization, anti-class II antibodies, and history of previous transplant. The desensitization protocol had limited efficacy in highly sensitized kidney transplant candidate because of the short period with antibody reduction and high frequency of rebound effect.

  10. Comparison of multiple rebond shear strengths of debonded brackets after preparation with sandblasting and CO2 laser

    Directory of Open Access Journals (Sweden)

    Mojgan Kachoei

    2016-08-01

    Full Text Available Background. Failure of orthodontic bracket bonds is a common occurrence during orthodontic treatment. Different techniques have been suggested in the literature to remove resin residues from the bracket bases and enamel surfaces to prepare the surfaces again after debonding. This study attempted to compare multiple rebond shear strengths (SBS of debonded brackets following preparation with sandblasting and CO2 laser. Methods. The brackets were bonded on 30 human and bovine maxillary central incisors using self-curing composite resin. SBS was measured using Hounsfield testing machine. The brackets were rebonded for two other times after composite resin residues on their surfaces were removed, either with air abrasion or CO2 laser. The debonded brackets and enamel surfaces were also evaluated after each debonding procedure under a stereomicroscope in order to determine adhesive remnant index (ARI. SBS of debonded brackets after each step were compared between sandblast and CO2 laser groups. Results. We observed significant differences in SBS values between pre-recycling and first (P = 0.04, second (P = 0.007 and third recycling (P = 0.007 with laser. Recycling with sandblasting resulted in a decrease in SBS after the first and second recycling procedure; however, the SBS increased after the third recycling procedure, with no significant differences. Conclusion. SBS of brackets after recycling with sandblasting and laser beams was not significantly different, and both were at a favorable level. However, repeating the recycling procedure with sandblasting resulted in more favorable SBS compared to laser.

  11. Effect of Apheresis for ABO and HLA Desensitization on Anti-Measles Antibody Titers in Renal Transplantation

    Directory of Open Access Journals (Sweden)

    Ulf Schönermarck

    2011-01-01

    Full Text Available Desensitization strategies for ABO-incompatible renal transplants with plasma exchange (PE or specific immunoadsorption (IA decrease immunoglobulin levels. After recent measles outbreak and decreasing vaccination rates, we studied the impact of apheresis on anti-measles antibodies. Anti-measles antibodies were measured before desensitization, before transplantation and during followup in 12 patients with ABO incompatibility (2x PE only, 8x IA only, and 2x IA and PE and 3 patients with donor-specific HLA antibodies (all PE. Patients received rituximab, IVIG, and standard immunosuppressive therapy. All patients had detectable anti-measles antibodies before desensitization (mean 3238 mU/l, range 560–8100. After 3–6 PE sessions, titers decreased significantly to 1710 mU/l (<0.05, in one patient to nondetectable values, while IA only maintained protective titers. After a median followup of 64 days, anti-measles antibodies returned to baseline in all patients. Immunity against measles was temporarily reduced by apheresis but remained detectable in most patients at time of transplantation. Desensitization maintains long-term protective immunity against measles.

  12. Comment on the Morris and Suckerman Study of Therapist Warmth as a Factor in Automated Systematic Desensitization

    Science.gov (United States)

    McGlynn, F. Dudley; And Others

    1976-01-01

    Criticism of the study relating effects of therapist warmth to desensitization include: the use of surrogate, student subjects; nonstandard desensitization procedures; and no control group. Morris and Suckerman respond that the first two criticisms rely on selective reading of the literature and the third is irrelevant. (NG)

  13. Bacterial adhesion on conventional and self-ligating metallic brackets after surface treatment with plasma-polymerized hexamethyldisiloxane

    Science.gov (United States)

    Tupinambá, Rogerio Amaral; Claro, Cristiane Aparecida de Assis; Pereira, Cristiane Aparecida; Nobrega, Celestino José Prudente; Claro, Ana Paula Rosifini Alves

    2017-01-01

    ABSTRACT Introduction: Plasma-polymerized film deposition was created to modify metallic orthodontic brackets surface properties in order to inhibit bacterial adhesion. Methods: Hexamethyldisiloxane (HMDSO) polymer films were deposited on conventional (n = 10) and self-ligating (n = 10) stainless steel orthodontic brackets using the Plasma-Enhanced Chemical Vapor Deposition (PECVD) radio frequency technique. The samples were divided into two groups according to the kind of bracket and two subgroups after surface treatment. Scanning Electron Microscopy (SEM) analysis was performed to assess the presence of bacterial adhesion over samples surfaces (slot and wings region) and film layer integrity. Surface roughness was assessed by Confocal Interferometry (CI) and surface wettability, by goniometry. For bacterial adhesion analysis, samples were exposed for 72 hours to a Streptococcus mutans solution for biofilm formation. The values obtained for surface roughness were analyzed using the Mann-Whitney test while biofilm adhesion were assessed by Kruskal-Wallis and SNK test. Results: Significant statistical differences (p 0.05). Conclusion: Plasma-polymerized film deposition was only effective on reducing surface roughness and bacterial adhesion in conventional brackets. It was also noted that conventional brackets showed lower biofilm adhesion than self-ligating brackets despite the absence of film. PMID:28902253

  14. Bacterial adhesion on conventional and self-ligating metallic brackets after surface treatment with plasma-polymerized hexamethyldisiloxane

    Directory of Open Access Journals (Sweden)

    Rogerio Amaral Tupinambá

    Full Text Available ABSTRACT Introduction: Plasma-polymerized film deposition was created to modify metallic orthodontic brackets surface properties in order to inhibit bacterial adhesion. Methods: Hexamethyldisiloxane (HMDSO polymer films were deposited on conventional (n = 10 and self-ligating (n = 10 stainless steel orthodontic brackets using the Plasma-Enhanced Chemical Vapor Deposition (PECVD radio frequency technique. The samples were divided into two groups according to the kind of bracket and two subgroups after surface treatment. Scanning Electron Microscopy (SEM analysis was performed to assess the presence of bacterial adhesion over samples surfaces (slot and wings region and film layer integrity. Surface roughness was assessed by Confocal Interferometry (CI and surface wettability, by goniometry. For bacterial adhesion analysis, samples were exposed for 72 hours to a Streptococcus mutans solution for biofilm formation. The values obtained for surface roughness were analyzed using the Mann-Whitney test while biofilm adhesion were assessed by Kruskal-Wallis and SNK test. Results: Significant statistical differences (p 0.05. Conclusion: Plasma-polymerized film deposition was only effective on reducing surface roughness and bacterial adhesion in conventional brackets. It was also noted that conventional brackets showed lower biofilm adhesion than self-ligating brackets despite the absence of film.

  15. Crystal structure and dynamics of a lipid-induced potential desensitized-state of a pentameric ligand-gated channel

    Energy Technology Data Exchange (ETDEWEB)

    Basak, Sandip [Department of Physiology and Biophysics, School of Medicine, Case Western Reserve University, Cleveland, United States; Schmandt, Nicolaus [Department of Neuroscience, School of Medicine, Case Western Reserve University, Cleveland, United States; Gicheru, Yvonne [Department of Physiology and Biophysics, School of Medicine, Case Western Reserve University, Cleveland, United States; Chakrapani, Sudha [Department of Physiology and Biophysics, School of Medicine, Case Western Reserve University, Cleveland, United States

    2017-03-06

    Desensitization in pentameric ligand-gated ion channels plays an important role in regulating neuronal excitability. Here, we show that docosahexaenoic acid (DHA), a key ω-3 polyunsaturated fatty acid in synaptic membranes, enhances the agonist-induced transition to the desensitized state in the prokaryotic channel GLIC. We determined a 3.25 Å crystal structure of the GLIC-DHA complex in a potentially desensitized conformation. The DHA molecule is bound at the channel-periphery near the M4 helix and exerts a long-range allosteric effect on the pore across domain-interfaces. In this previously unobserved conformation, the extracellular-half of the pore-lining M2 is splayed open, reminiscent of the open conformation, while the intracellular-half is constricted, leading to a loss of both water and permeant ions. These findings, in combination with spin-labeling/EPR spectroscopic measurements in reconstituted-membranes, provide novel mechanistic details of desensitization in pentameric channels.

  16. Design assessment of triangular support bracket for manufacturability

    International Nuclear Information System (INIS)

    Kim, Yu-Gyeong; Jung, Yung-Jin; Kim, Hyun-Soo; Ahn, Hee-Jae

    2015-01-01

    Highlights: • Various designs for ITER triangular support bracket are proposed in terms of efficient manufacturability. • An optimized design for structural safety is determined in accordance with RCC-MR. • This result is reconfirmed by cross-checking in comparison with the IO baseline of integrity. - Abstract: The triangular support is connected structurally and hydraulically with the inner shell of the vacuum vessel and its main role is to keep plasma vertical stability during operational disruptions. Korea is responsible for the procurement of sectors 1 and 6 of the main vessel including triangular support. At present, design review for its fabrication by ITER Korea and Hyundai Heavy Industries, Co., Ltd. is in progress. This paper presents the results on various designs for triangular support bracket in terms of manufacturability considering both easiness of non-destructive evaluation and fabrication efficiency. The several designs are proposed and evaluated under the most critical loading condition using elastic and limit analysis with fatigue evaluation. Consequently, an optimized design for structural safety is determined in accordance with RCC-MR. This result is reconfirmed by cross-checking in comparison with the baseline of integrity that already had been determined by ITER Organization. The design deviation requests of triangular support bracket have been submitted to ITER Organization and Agreed Notified Body for approval, and their verification is currently under discussion.

  17. The Effect on Final Bond Strength of Bracket Manipulation Subsequent To Initial Positioning

    Science.gov (United States)

    Beebe, David A.

    The shear bond strength of light activated orthodontic adhesives varies according to the composition of the material, placement protocol, and time prior to light curing. Manipulating brackets after their initial placement on a tooth can disrupt the adhesive's polymerization and compromise final bond strength. No previous research has investigated how a specific degree of manipulation, and the amount of time elapsed prior to curing, under specific lighting conditions, affects the orthodontic adhesives shear bond strength. Victory SeriesRTM, MBT prescription, premolar (3M Unitek, Monrovia, CA) orthodontic brackets were bonded using three different adhesives to sixty (60) bicuspids and varying the time after bracket manipulation before curing. The shear bond strength was calculated for each specimen. The brackets were debonded and the same teeth were rebonded with new, identical brackets, using the same protocol and under the same conditions. The results showed a statistically significant difference between the shear bond strength of Transbond XT and Grengloo, with Transbond XT having the highest strength. There was also a statistically significance difference in bond strength between the group cured 30 seconds after manipulation and the groups manipulated at different intervals prior to curing, with the 30 second group having the highest bond strength. This study confirms that various orthodontic adhesives have different bond strengths depending on manipulation and varying times prior to curing each adhesive.

  18. Plaque Index in Multi-Bracket Fixed Appliances

    International Nuclear Information System (INIS)

    Rahim, Z.H.; Shaikh, S.; Razak, F.A.

    2014-01-01

    To compare the plaque index in patients receiving multi-bracket fixed orthodontic treatment for various factors like age, gender, socio-economic status, brushing practices, meal habits, types of brackets, types of ligations, use of mouthwash and duration of treatment. Study Design: Cross-sectional analytical study. Place and Duration of Study: Orthodontics Clinic, The Aga Khan University Hospital, from September to November 2011. Methodology: Socio-demographic and clinical modalities were defined and recorded for 131 patients having multi-bracket fixed appliances. The plaque index of subjects were recorded according to the Silness and Loe plaque index method. Independent sample t-test was used to see difference in plaque index in factors having two variables. One way ANOVA and Post-Hoc Tukey tests were used to see difference in plaque index in factors having three variables. Kappa statistics was used to assess inter examiner reliability. P-value 0.05 was taken to be significant. Results: The sample comprised of 37% males (n = 48) and 63% females (n = 83). The plaque index had statistically significant association with practice of brushing i.e., timing of brushing (p=0.001), method of brushing (p=0.08), type of ligatures (p=0.05) and frequency of visits (p=0.01). Conclusion: The plaque accumulation is significantly decreased in subjects who brush the teeth twice or more than twice a day and those who brush their teeth after breakfast. The use of interdental brush and stainless steel ligatures had significantly low plaque. Subjects presenting with more frequent appointments of short-period had significantly less plaque. (author)

  19. Effect of desensitizing toothpastes on dentin

    Directory of Open Access Journals (Sweden)

    Shelon Cristina Souza Pinto

    2012-10-01

    Full Text Available The objective of this study was to analyze the effects of toothbrushing with desensitizing toothpastes on dentin permeability and dentinal tubule occlusion. Fifty rats provided two hundred incisor teeth divided into five groups: DW, brushed with distilled water (control; FT, brushed with fluoride toothpaste; SCT, brushed with strontium chloride toothpaste; PCT, brushed with potassium citrate toothpaste; and PNT, brushed with potassium nitrate toothpaste. Cavities were prepared to expose the dentinal tubules, and the incisor teeth were brushed using the experimental agents. After each treatment, Evans blue dye solution was applied to the teeth. Dentin permeability was analyzed using scanning electron microscopy and energy-dispersive X-rays (EDX. There were significant differences (p < 0.0001, ANOVA among the groups regarding dentin permeability, number of dentinal tubules, diameter of dentinal tubules, and opened tubular area. In the SCT, PCT and PNT groups, opened and partially occluded tubules, deposits, and a few smear layers were observed. In the DW and FT groups, most of the dentinal tubules were open, with no deposits or smear layers on the dentin. EDX revealed peaks of calcium and phosphorus in all of the groups, as well as traces of strontium in the SCT group and of potassium in the PCT and PNT groups. Desensitizing toothpaste decreased dentin permeability, although it produced only partial dentin tubule occlusion.

  20. Comparison of frictional resistance among conventional, active and passive selfligating brackets with different combinations of arch wires: a finite elements study.

    Science.gov (United States)

    Gómez, Sandra L; Montoya, Yesid; Garcia, Nora L; Virgen, Ana L; Botero, Javier E

    2016-09-01

    The aim of this study was to compare frictional resistance among conventional, passive and active selfligating brackets using Finite Elements Analysis (FEA). Seventynine (79) slide tests were performed by combining an upper first bicuspid conventional bracket, 0.018" stainless steel wires and 0.010" ligature by means of an INSTRON 3345 load system to obtain average maximum static frictional resistance (MSFR). This value was compared to the FR (frictional resistance) obtained by simulation of a slide of the same combination by FEA following conventional bracket modeling by means of Computer Aided Design (CAD). Once the FEA was validated, bracket CADs were designed (upper right first bicuspid conventional, active and passive selfligating bracket) and bracket properties calculated. MSFR was compared among conventional, active and passive selfligating brackets with different alloys and archwire cross sections such as 0.018", 0.019" x 0.025"and 0.020" x 0.020". Passive selfligating brackets had the lowest MSFR, followed by conventional brackets and active selfligating brackets. In conventional brackets, a 0.018" archwire produced a linear pattern of stress with maximum concentration at the center. Conversely, stress in 0.020 x 0.020" and 0.019 x 0.025" archwires was distributed across the width of the slot. The highest normal forces were 1.53 N for the 0.018" archwire, 4.85 N for the 0.020 x 0.020" archwire and 8.18 N for the 0.019 x 0.025" archwire. Passive selfligating brackets presented less frictional resistance than conventional and active selfligating brackets. Regardless of bracket type, greater contact area between the slot and the archwire and the spring clip increased frictional resistance. Sociedad Argentina de Pediatría.